18:16:12.914 DRIVER ███████╗ ██╗ ██╗ █████╗ ██╗ ██╗ ███████╗ ██╗ ███████╗ ╚══███╔╝ ██║ ██║ ██╔══██╗ ██║ ██║ ██╔════╝ ██║ ██╔════╝ ███╔╝ ██║ █╗ ██║ ███████║ ██║ ██║ █████╗ █████╗ ██║ ███████╗ ███╔╝ ██║███╗██║ ██╔══██║ ╚██╗ ██╔╝ ██╔══╝ ╚════╝ ██ ██║ ╚════██║ ███████╗ ╚███╔███╔╝ ██║ ██║ ╚████╔╝ ███████╗ ╚█████╔╝ ███████║ ╚══════╝ ╚══╝╚══╝ ╚═╝ ╚═╝ ╚═══╝ ╚══════╝ ╚════╝ ╚══════╝ 18:16:12.918 DRIVER version 2.12.2 18:16:12.920 DRIVER 18:16:12.920 DRIVER starting driver... 18:16:12.920 DRIVER opening serial port /dev/ttyACM0 18:16:12.948 DRIVER serial port opened 18:16:12.955 SERIAL » [NAK] (0x15) 18:16:12.981 SERIAL « 0x0109000400080380034832 (11 bytes) 18:16:12.996 DRIVER Cannot handle message because the driver is not ready to handle it yet. 18:16:12.983 SERIAL Buffer := 0x0109000400080380034832 (11 bytes) 18:16:12.992 SERIAL » [ACK] (0x06) 18:16:12.997 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:13.000 SERIAL « 0x01 (1 bytes) 18:16:13.001 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:13.012 DRIVER Dropping message because the driver is not ready to handle it yet. 18:16:13.007 SERIAL « 0x0c00040008064303014201c239 (13 bytes) 18:16:13.008 SERIAL Buffer := 0x010c00040008064303014201c239 (14 bytes) 18:16:13.012 SERIAL » [ACK] (0x06) 18:16:13.013 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:13.018 SERIAL « 0x010a00040008044608007fcc (12 bytes) 18:16:13.025 DRIVER Cannot handle message because the driver is not ready to handle it yet. 18:16:13.019 SERIAL Buffer := 0x010a00040008044608007fcc (12 bytes) 18:16:13.023 SERIAL » [ACK] (0x06) 18:16:13.025 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:14.459 DRIVER loading configuration... 18:16:14.875 DRIVER beginning interview... 18:16:14.894 SERIAL » 0x01030015e9 (5 bytes) 18:16:14.877 DRIVER added request handler for AddNodeToNetwork (0x4a)... 1 registered 18:16:14.878 DRIVER added request handler for RemoveNodeFromNetwork (0x4b)... 1 registered 18:16:14.894 DRIVER » [REQ] [GetControllerVersion] [P: Controller] 18:16:14.885 CNTRLR beginning interview... 18:16:14.886 CNTRLR querying version info... 18:16:14.899 SERIAL « [ACK] (0x06) 18:16:14.901 DRIVER ACK received from controller for current transaction 18:16:14.902 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:14.907 DRIVER « [RES] [GetControllerVersion] [final] payload: 0x5a2d5761766520342e33380001 18:16:14.910 CNTRLR received version info: controller type: Static Controller library version: Z-Wave 4.38 18:16:14.903 SERIAL « 0x011001155a2d5761766520342e3338000199 (18 bytes) 18:16:14.904 SERIAL Buffer := 0x011001155a2d5761766520342e3338000199 (18 bytes) 18:16:14.905 SERIAL » [ACK] (0x06) 18:16:14.912 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:14.908 DRIVER ACK already received, resolving transaction 18:16:14.909 DRIVER resuming send queue 18:16:14.914 DRIVER » [REQ] [GetControllerId] [P: Controller] 18:16:14.915 DRIVER The send queue is empty 18:16:14.910 CNTRLR querying controller IDs... 18:16:14.914 SERIAL » 0x01030020dc (5 bytes) 18:16:14.919 SERIAL « [ACK] (0x06) 18:16:14.920 DRIVER ACK received from controller for current transaction 18:16:14.921 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:14.925 DRIVER « [RES] [GetControllerId] [final] payload: 0xe84eb4ea01 18:16:14.928 CNTRLR received controller IDs: home ID: 0xe84eb4ea own node ID: 1 18:16:14.922 SERIAL « 0x01080120e84eb4ea012f (10 bytes) 18:16:14.923 SERIAL Buffer := 0x01080120e84eb4ea012f (10 bytes) 18:16:14.924 SERIAL » [ACK] (0x06) 18:16:14.930 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:14.932 SERIAL » 0x01030005f9 (5 bytes) 18:16:14.926 DRIVER ACK already received, resolving transaction 18:16:14.926 DRIVER resuming send queue 18:16:14.931 DRIVER » [REQ] [GetControllerCapabilities] [P: Controller] 18:16:14.932 DRIVER The send queue is empty 18:16:14.928 CNTRLR querying controller capabilities... 18:16:14.936 SERIAL « [ACK] (0x06) 18:16:14.937 DRIVER ACK received from controller for current transaction 18:16:14.938 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:14.942 DRIVER « [RES] [GetControllerCapabilities] [final] payload: 0x1c 18:16:14.944 CNTRLR received controller capabilities: controller role: primary is in other network: false is SIS present: true was real primary: true is a SUC: true 18:16:14.939 SERIAL « 0x010401051ce3 (6 bytes) 18:16:14.940 SERIAL Buffer := 0x010401051ce3 (6 bytes) 18:16:14.941 SERIAL » [ACK] (0x06) 18:16:14.946 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:14.948 SERIAL » 0x01030007fb (5 bytes) 18:16:14.942 DRIVER ACK already received, resolving transaction 18:16:14.943 DRIVER resuming send queue 18:16:14.948 DRIVER » [REQ] [GetSerialApiCapabilities] [P: Controller] 18:16:14.949 DRIVER The send queue is empty 18:16:14.945 CNTRLR querying API capabilities... 18:16:14.953 SERIAL « [ACK] (0x06) 18:16:14.954 DRIVER ACK received from controller for current transaction 18:16:14.954 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:14.959 DRIVER « [RES] [GetSerialApiCapabilities] [final] payload: 0x0507011504000001fe83ff88cf1f0000fb9f7da067008080008086000000e8730 0000e0000401a00 18:16:14.962 CNTRLR received API capabilities: serial API version: 5.7 manufacturer ID: 0x0115 product type: 0x0400 product ID: 0x01 supported functions: · GetSerialApiInitData (0x02) · FUNC_ID_SERIAL_API_APPL_NODE_INFORMATION (0x03) · ApplicationCommand (0x04) · GetControllerCapabilities (0x05) · SetSerialApiTimeouts (0x06) · GetSerialApiCapabilities (0x07) · FUNC_ID_SERIAL_API_SOFT_RESET (0x08) · UNKNOWN_FUNC_UNKNOWN_0x09 (0x09) · UNKNOWN_FUNC_UNKNOWN_0x0a (0x0a) · UNKNOWN_FUNC_RF_RECEIVE_MODE (0x10) · UNKNOWN_FUNC_SET_SLEEP_MODE (0x11) · FUNC_ID_ZW_SEND_NODE_INFORMATION (0x12) · SendData (0x13) · UNKNOWN_FUNC_SEND_DATA_MULTI (0x14) · GetControllerVersion (0x15) · UNKNOWN_FUNC_SEND_DATA_ABORT (0x16) · FUNC_ID_ZW_R_F_POWER_LEVEL_SET (0x17) · UNKNOWN_FUNC_SEND_DATA_META (0x18) · FUNC_ID_ZW_GET_RANDOM (0x1c) · GetControllerId (0x20) · UNKNOWN_FUNC_MEMORY_GET_BYTE (0x21) · UNKNOWN_FUNC_MEMORY_PUT_BYTE (0x22) · UNKNOWN_FUNC_MEMORY_GET_BUFFER (0x23) · UNKNOWN_FUNC_MEMORY_PUT_BUFFER (0x24) · UNKNOWN_FUNC_UNKNOWN_0x27 (0x27) · UNKNOWN_FUNC_UNKNOWN_0x28 (0x28) · UNKNOWN_FUNC_UNKNOWN_0x29 (0x29) · UNKNOWN_FUNC_UNKNOWN_0x2a (0x2a) · UNKNOWN_FUNC_UNKNOWN_0x2b (0x2b) · UNKNOWN_FUNC_UNKNOWN_0x2c (0x2c) · UNKNOWN_FUNC_UNKNOWN_0x2d (0x2d) · GetNodeProtocolInfo (0x41) · HardReset (0x42) · FUNC_ID_ZW_REPLICATION_COMMAND_COMPLETE (0x44) · FUNC_ID_ZW_REPLICATION_SEND_DATA (0x45) · FUNC_ID_ZW_ASSIGN_RETURN_ROUTE (0x46) · FUNC_ID_ZW_DELETE_RETURN_ROUTE (0x47) · RequestNodeNeighborUpdate (0x48) · ApplicationUpdateRequest (0x49) · AddNodeToNetwork (0x4a) · RemoveNodeFromNetwork (0x4b) · FUNC_ID_ZW_CREATE_NEW_PRIMARY (0x4c) · FUNC_ID_ZW_CONTROLLER_CHANGE (0x4d) · FUNC_ID_ZW_SET_LEARN_MODE (0x50) · FUNC_ID_ZW_ASSIGN_SUC_RETURN_ROUTE (0x51) · FUNC_ID_ZW_REQUEST_NETWORK_UPDATE (0x53) · FUNC_ID_ZW_SET_SUC_NODE_ID (0x54) · FUNC_ID_ZW_DELETE_SUC_RETURN_ROUTE (0x55) · GetSUCNodeId (0x56) · UNKNOWN_FUNC_SEND_SUC_ID (0x57) · FUNC_ID_ZW_EXPLORE_REQUEST_INCLUSION (0x5e) · RequestNodeInfo (0x60) · RemoveFailedNode (0x61) · IsFailedNode (0x62) · FUNC_ID_ZW_REPLACE_FAILED_NODE (0x63) · UNKNOWN_FUNC_UNKNOWN_0x66 (0x66) · UNKNOWN_FUNC_UNKNOWN_0x67 (0x67) · UNKNOWN_FUNC_UNKNOWN_0x78 (0x78) · GetRoutingInfo (0x80) · UNKNOWN_FUNC_LOCK_ROUTE_RESPONSE (0x90) · UNKNOWN_FUNC_UNKNOWN_0x92 (0x92) · UNKNOWN_FUNC_UNKNOWN_0x93 (0x93) · UNKNOWN_FUNC_UNKNOWN_0x98 (0x98) · UNKNOWN_FUNC_UNKNOWN_0xB4 (0xb4) · UNKNOWN_FUNC_WATCH_DOG_ENABLE (0xb6) · UNKNOWN_FUNC_WATCH_DOG_DISABLE (0xb7) · UNKNOWN_FUNC_WATCH_DOG_KICK (0xb8) · UNKNOWN_FUNC_UNKNOWN_0xB9 (0xb9) · UNKNOWN_FUNC_RF_POWERLEVEL_GET (0xba) · UNKNOWN_FUNC_GET_LIBRARY_TYPE (0xbd) · UNKNOWN_FUNC_SEND_TEST_FRAME (0xbe) · UNKNOWN_FUNC_GET_PROTOCOL_STATUS (0xbf) · UNKNOWN_FUNC_UNKNOWN_0xD2 (0xd2) · UNKNOWN_FUNC_UNKNOWN_0xD3 (0xd3) · UNKNOWN_FUNC_UNKNOWN_0xD4 (0xd4) · UNKNOWN_FUNC_UNKNOWN_0xEF (0xef) · UNKNOWN_FUNC_UNKNOWN_0xF2 (0xf2) · UNKNOWN_FUNC_UNKNOWN_0xF4 (0xf4) · UNKNOWN_FUNC_UNKNOWN_0xF5 (0xf5) 18:16:14.956 SERIAL « 0x012b01070507011504000001fe83ff88cf1f0000fb9f7da067008080008086000 (45 bytes) 000e87300000e0000401a000c 18:16:14.956 SERIAL Buffer := 0x012b01070507011504000001fe83ff88cf1f0000fb9f7da06700808 (45 bytes) 0008086000000e87300000e0000401a000c 18:16:14.958 SERIAL » [ACK] (0x06) 18:16:14.964 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:14.966 SERIAL » 0x01030056aa (5 bytes) 18:16:14.960 DRIVER ACK already received, resolving transaction 18:16:14.960 DRIVER resuming send queue 18:16:14.966 DRIVER » [REQ] [GetSUCNodeId] [P: Controller] 18:16:14.967 DRIVER The send queue is empty 18:16:14.963 CNTRLR finding SUC... 18:16:14.971 SERIAL « [ACK] (0x06) 18:16:14.972 DRIVER ACK received from controller for current transaction 18:16:14.973 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:14.976 DRIVER « [RES] [GetSUCNodeId] [final] payload: 0x01 18:16:14.978 CNTRLR SUC has node ID 1 18:16:14.974 SERIAL « 0x0104015601ad (6 bytes) 18:16:14.974 SERIAL Buffer := 0x0104015601ad (6 bytes) 18:16:14.975 SERIAL » [ACK] (0x06) 18:16:14.981 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:14.983 SERIAL » 0x01030002fe (5 bytes) 18:16:14.977 DRIVER ACK already received, resolving transaction 18:16:14.977 DRIVER resuming send queue 18:16:14.982 DRIVER » [REQ] [GetSerialApiInitData] [P: Controller] 18:16:14.984 DRIVER The send queue is empty 18:16:14.979 CNTRLR querying node information... 18:16:14.988 SERIAL « [ACK] (0x06) 18:16:14.989 DRIVER ACK received from controller for current transaction 18:16:14.989 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:15.082 SERIAL « 0x01 (1 bytes) 18:16:15.083 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:15.086 DRIVER « [RES] [GetSerialApiInitData] [final] payload: 0x05081dff000000000000000000000000000000000000000000000000000000000 500 18:16:15.089 CNTRLR received node information: controller role: primary controller is a SUC: true controller is a slave: false controller supports timers: false nodes in the network: 1, 2, 3, 4, 5, 6, 7, 8 18:16:15.084 SERIAL « 0x25010205081dff000000000000000000000000000000000000000000000000000 (38 bytes) 00000050033 18:16:15.084 SERIAL Buffer := 0x0125010205081dff000000000000000000000000000000000000000 (39 bytes) 00000000000000000050033 18:16:15.086 SERIAL » [ACK] (0x06) 18:16:15.096 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:15.099 SERIAL » 0x01050006640f97 (7 bytes) 18:16:15.087 DRIVER ACK already received, resolving transaction 18:16:15.088 DRIVER resuming send queue 18:16:15.098 DRIVER » [REQ] [SetSerialApiTimeouts] [P: Controller] payload: 0x640f 18:16:15.100 DRIVER The send queue is empty 18:16:15.094 CNTRLR setting serial API timeouts: ack = 1000 ms, byte = 150 ms 18:16:15.105 SERIAL « [ACK] (0x06) 18:16:15.106 DRIVER ACK received from controller for current transaction 18:16:15.106 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:15.110 DRIVER « [RES] [SetSerialApiTimeouts] [final] payload: 0x640f 18:16:15.112 CNTRLR serial API timeouts overwritten. The old values were: ack = 1000 ms, byte = 15 0 ms 18:16:15.108 SERIAL « 0x01050106640f96 (7 bytes) 18:16:15.108 SERIAL Buffer := 0x01050106640f96 (7 bytes) 18:16:15.109 SERIAL » [ACK] (0x06) 18:16:15.113 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:15.110 DRIVER ACK already received, resolving transaction 18:16:15.111 DRIVER resuming send queue 18:16:15.114 DRIVER driver ready 18:16:15.124 DRIVER The send queue is empty 18:16:15.113 CNTRLR Interview completed 18:16:15.142 SERIAL » 0x0104004101bb (6 bytes) 18:16:15.141 DRIVER » [Node 001] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x01 18:16:15.132 CNTRLR [Node 001] Beginning interview - last completed stage: None 18:16:15.134 CNTRLR [Node 001] new node, doing a full interview... 18:16:15.136 CNTRLR » [Node 001] querying protocol info... 18:16:15.150 SERIAL « [ACK] (0x06) 18:16:15.151 DRIVER ACK received from controller for current transaction 18:16:15.153 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:15.163 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x931601020201 18:16:15.166 CNTRLR « [Node 001] received response for protocol info: basic device class: Routing Slave (0x02) generic device class: Static Controller (0x02) specific device class: PC Controller (0x01) is a listening device: true is frequent listening: false is a routing device: false is a secure device: false is a beaming device: true is a listening device: true maximum baud rate: 40000 kbps version: 4 18:16:15.158 SERIAL « 0x0109014193160102020133 (11 bytes) 18:16:15.159 SERIAL Buffer := 0x0109014193160102020133 (11 bytes) 18:16:15.162 SERIAL » [ACK] (0x06) 18:16:15.169 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:15.163 DRIVER ACK already received, resolving transaction 18:16:15.164 DRIVER resuming send queue 18:16:15.171 DRIVER The send queue is empty 18:16:15.178 CNTRLR [Node 001] Interview stage completed: ProtocolInfo 18:16:15.190 DRIVER » [Node 001] [REQ] [GetRoutingInfo] [P: Controller] removeNonRepeaters: false removeBadLinks: false 18:16:15.191 SERIAL » 0x010700800100000079 (9 bytes) 18:16:15.180 CNTRLR [Node 001] not querying node info from the controller 18:16:15.181 CNTRLR [Node 001] Interview stage completed: NodeInfo 18:16:15.185 CNTRLR [Node 001] Interview stage completed: CommandClasses 18:16:15.186 CNTRLR [Node 001] Interview stage completed: OverwriteConfig 18:16:15.187 CNTRLR » [Node 001] requesting node neighbors... 18:16:15.195 SERIAL « [ACK] (0x06) 18:16:15.196 DRIVER ACK received from controller for current transaction 18:16:15.196 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:15.201 DRIVER « [RES] [GetRoutingInfo] [final] node ids: 2, 3, 4, 5, 6, 7, 8 18:16:15.203 CNTRLR « [Node 001] node neighbors received: 2, 3, 4, 5, 6, 7, 8 18:16:15.198 SERIAL « 0x01200180fe0000000000000000000000000000000000000000000000000000000 (34 bytes) 0a0 18:16:15.198 SERIAL Buffer := 0x01200180fe000000000000000000000000000000000000000000000 (34 bytes) 00000000000a0 18:16:15.200 SERIAL » [ACK] (0x06) 18:16:15.204 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:15.232 SERIAL » 0x0104004102b8 (6 bytes) 18:16:15.202 DRIVER ACK already received, resolving transaction 18:16:15.202 DRIVER resuming send queue 18:16:15.232 DRIVER » [Node 002] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x02 18:16:15.234 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.235 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.236 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.236 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.237 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.237 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.238 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.204 CNTRLR [Node 001] Interview stage completed: Neighbors 18:16:15.205 CNTRLR [Node 001] Interview completed 18:16:15.208 CNTRLR [Node 001] The node is ready to be used 18:16:15.209 CNTRLR [Node 001] node is ready 18:16:15.212 CNTRLR [Node 002] Beginning interview - last completed stage: None 18:16:15.212 CNTRLR [Node 002] new node, doing a full interview... 18:16:15.213 CNTRLR » [Node 002] querying protocol info... 18:16:15.214 CNTRLR [Node 003] Beginning interview - last completed stage: None 18:16:15.214 CNTRLR [Node 003] new node, doing a full interview... 18:16:15.215 CNTRLR » [Node 003] querying protocol info... 18:16:15.217 CNTRLR [Node 004] Beginning interview - last completed stage: None 18:16:15.217 CNTRLR [Node 004] new node, doing a full interview... 18:16:15.218 CNTRLR » [Node 004] querying protocol info... 18:16:15.219 CNTRLR [Node 005] Beginning interview - last completed stage: None 18:16:15.220 CNTRLR [Node 005] new node, doing a full interview... 18:16:15.220 CNTRLR » [Node 005] querying protocol info... 18:16:15.221 CNTRLR [Node 006] Beginning interview - last completed stage: None 18:16:15.222 CNTRLR [Node 006] new node, doing a full interview... 18:16:15.223 CNTRLR » [Node 006] querying protocol info... 18:16:15.225 CNTRLR [Node 007] Beginning interview - last completed stage: None 18:16:15.225 CNTRLR [Node 007] new node, doing a full interview... 18:16:15.226 CNTRLR » [Node 007] querying protocol info... 18:16:15.227 CNTRLR [Node 008] Beginning interview - last completed stage: None 18:16:15.228 CNTRLR [Node 008] new node, doing a full interview... 18:16:15.229 CNTRLR » [Node 008] querying protocol info... 18:16:15.242 SERIAL « [ACK] (0x06) 18:16:15.243 DRIVER ACK received from controller for current transaction 18:16:15.244 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:15.250 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c00040804 18:16:15.270 CNTRLR « [Node 002] received response for protocol info: basic device class: Static Controller (0x04) generic device class: Thermostat (0x08) specific device class: Setpoint Thermostat (0x04) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 18:16:15.246 SERIAL « 0x01090141539c0004080471 (11 bytes) 18:16:15.247 SERIAL Buffer := 0x01090141539c0004080471 (11 bytes) 18:16:15.249 SERIAL » [ACK] (0x06) 18:16:15.275 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:15.250 DRIVER ACK already received, resolving transaction 18:16:15.268 DRIVER resuming send queue 18:16:15.280 DRIVER » [Node 003] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x03 18:16:15.281 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.282 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.271 CNTRLR [Node 002] The node is now awake. 18:16:15.276 CNTRLR [Node 002] Interview stage completed: ProtocolInfo 18:16:15.277 CNTRLR » [Node 002] querying node info... 18:16:15.281 SERIAL » 0x0104004103b9 (6 bytes) 18:16:15.289 SERIAL « [ACK] (0x06) 18:16:15.290 DRIVER ACK received from controller for current transaction 18:16:15.295 CNTRLR « [Node 003] received response for protocol info: basic device class: Static Controller (0x04) generic device class: Thermostat (0x08) specific device class: Setpoint Thermostat (0x04) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 18:16:15.291 SERIAL « 0x0601090141539c0004080471 (12 bytes) 18:16:15.291 SERIAL Buffer := 0x01090141539c0004080471 (11 bytes) 18:16:15.292 SERIAL » [ACK] (0x06) 18:16:15.298 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:15.303 SERIAL » 0x0104004104be (6 bytes) 18:16:15.293 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c00040804 18:16:15.294 DRIVER ACK already received, resolving transaction 18:16:15.294 DRIVER resuming send queue 18:16:15.302 DRIVER » [Node 004] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x04 18:16:15.304 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.304 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.297 CNTRLR [Node 003] The node is now awake. 18:16:15.299 CNTRLR [Node 003] Interview stage completed: ProtocolInfo 18:16:15.300 CNTRLR » [Node 003] querying node info... 18:16:15.312 SERIAL « [ACK] (0x06) 18:16:15.313 DRIVER ACK received from controller for current transaction 18:16:15.318 CNTRLR « [Node 004] received response for protocol info: basic device class: Static Controller (0x04) generic device class: Thermostat (0x08) specific device class: Setpoint Thermostat (0x04) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 18:16:15.314 SERIAL « 0x0601090141539c0004080471 (12 bytes) 18:16:15.314 SERIAL Buffer := 0x01090141539c0004080471 (11 bytes) 18:16:15.315 SERIAL » [ACK] (0x06) 18:16:15.320 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:15.324 SERIAL » 0x0104004105bf (6 bytes) 18:16:15.316 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c00040804 18:16:15.317 DRIVER ACK already received, resolving transaction 18:16:15.317 DRIVER resuming send queue 18:16:15.324 DRIVER » [Node 005] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x05 18:16:15.325 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.325 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.319 CNTRLR [Node 004] The node is now awake. 18:16:15.321 CNTRLR [Node 004] Interview stage completed: ProtocolInfo 18:16:15.322 CNTRLR » [Node 004] querying node info... 18:16:15.333 SERIAL « [ACK] (0x06) 18:16:15.334 DRIVER ACK received from controller for current transaction 18:16:15.338 CNTRLR « [Node 005] received response for protocol info: basic device class: Static Controller (0x04) generic device class: Thermostat (0x08) specific device class: Setpoint Thermostat (0x04) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 18:16:15.335 SERIAL « 0x0601090141539c0004080471 (12 bytes) 18:16:15.335 SERIAL Buffer := 0x01090141539c0004080471 (11 bytes) 18:16:15.336 SERIAL » [ACK] (0x06) 18:16:15.341 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:15.345 SERIAL » 0x0104004106bc (6 bytes) 18:16:15.336 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c00040804 18:16:15.337 DRIVER ACK already received, resolving transaction 18:16:15.337 DRIVER resuming send queue 18:16:15.345 DRIVER » [Node 006] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x06 18:16:15.346 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.351 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.339 CNTRLR [Node 005] The node is now awake. 18:16:15.341 CNTRLR [Node 005] Interview stage completed: ProtocolInfo 18:16:15.342 CNTRLR » [Node 005] querying node info... 18:16:15.388 SERIAL « [ACK] (0x06) 18:16:15.392 DRIVER ACK received from controller for current transaction 18:16:15.396 CNTRLR « [Node 006] received response for protocol info: basic device class: Static Controller (0x04) generic device class: Thermostat (0x08) specific device class: Setpoint Thermostat (0x04) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 18:16:15.392 SERIAL « 0x0601090141539c0004080471 (12 bytes) 18:16:15.393 SERIAL Buffer := 0x01090141539c0004080471 (11 bytes) 18:16:15.394 SERIAL » [ACK] (0x06) 18:16:15.398 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:15.403 SERIAL » 0x0104004107bd (6 bytes) 18:16:15.395 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c00040804 18:16:15.395 DRIVER ACK already received, resolving transaction 18:16:15.396 DRIVER resuming send queue 18:16:15.402 DRIVER » [Node 007] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x07 18:16:15.403 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.404 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.397 CNTRLR [Node 006] The node is now awake. 18:16:15.399 CNTRLR [Node 006] Interview stage completed: ProtocolInfo 18:16:15.399 CNTRLR » [Node 006] querying node info... 18:16:15.411 SERIAL « [ACK] (0x06) 18:16:15.411 DRIVER ACK received from controller for current transaction 18:16:15.412 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:15.415 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0xd39c01041101 18:16:15.417 CNTRLR « [Node 007] received response for protocol info: basic device class: Static Controller (0x04) generic device class: Multilevel Switch (0x11) specific device class: Multilevel Power Switch (0x01) is a listening device: true is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: true maximum baud rate: 40000 kbps version: 4 18:16:15.413 SERIAL « 0x01090141d39c01041101ec (11 bytes) 18:16:15.414 SERIAL Buffer := 0x01090141d39c01041101ec (11 bytes) 18:16:15.414 SERIAL » [ACK] (0x06) 18:16:15.418 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:15.416 DRIVER ACK already received, resolving transaction 18:16:15.416 DRIVER resuming send queue 18:16:15.421 DRIVER » [Node 007] [REQ] [RequestNodeInfo] [P: NodeQuery] payload: 0x07 18:16:15.423 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.418 CNTRLR [Node 007] Interview stage completed: ProtocolInfo 18:16:15.418 CNTRLR » [Node 007] querying node info... 18:16:15.422 SERIAL » 0x01040060079c (6 bytes) 18:16:15.431 SERIAL « [ACK] (0x06) 18:16:15.432 DRIVER ACK received from controller for current transaction 18:16:15.433 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:15.450 SERIAL « 0x01040160019b (6 bytes) 18:16:15.455 DRIVER « [RES] [RequestNodeInfo] [confirmation] payload: 0x01 18:16:15.452 SERIAL Buffer := 0x01040160019b (6 bytes) 18:16:15.453 SERIAL » [ACK] (0x06) 18:16:15.458 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:15.567 SERIAL « 0x01 (1 bytes) 18:16:15.568 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:15.569 SERIAL « 0x1900498407130411015e865a72732725263271858e5970ef26 (25 bytes) 18:16:15.569 SERIAL [incomplete] Buffer := 0x011900498407130411015e865a7273272526327185 (26 bytes) 8e5970ef26 18:16:15.572 SERIAL « 0x24 (1 bytes) 18:16:15.575 DRIVER « [Node 007] [REQ] [ApplicationUpdateRequest] [final] payload: 0x8407130411015e865a72732725263271858e5970ef26 18:16:15.576 CNTRLR [Node 007] The node is now awake. 18:16:15.572 SERIAL Buffer := 0x011900498407130411015e865a72732725263271858e5970ef2624 (27 bytes) 18:16:15.574 SERIAL » [ACK] (0x06) 18:16:15.581 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:15.582 SERIAL » 0x0104004108b2 (6 bytes) 18:16:15.578 DRIVER ACK already received, resolving transaction 18:16:15.578 DRIVER resuming send queue 18:16:15.582 DRIVER » [Node 008] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x08 18:16:15.583 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.579 CNTRLR « [Node 007] node info received supported CCs: · Z-Wave Plus Info · Version · Device Reset Locally · Manufacturer Specific · Powerlevel · All Switch · Binary Switch · Multilevel Switch · Meter · Notification · Association · Multi Channel Association · Association Group Information · Configuration controlled CCs: · Multilevel Switch 18:16:15.599 SERIAL « [ACK] (0x06) 18:16:15.600 DRIVER ACK received from controller for current transaction 18:16:15.606 CNTRLR « [Node 008] received response for protocol info: basic device class: Static Controller (0x04) generic device class: Thermostat (0x08) specific device class: Setpoint Thermostat (0x04) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 18:16:15.601 SERIAL « 0x0601090141539c0004080471 (12 bytes) 18:16:15.602 SERIAL Buffer := 0x01090141539c0004080471 (11 bytes) 18:16:15.603 SERIAL » [ACK] (0x06) 18:16:15.608 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:15.612 SERIAL » 0x010400600299 (6 bytes) 18:16:15.604 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c00040804 18:16:15.604 DRIVER ACK already received, resolving transaction 18:16:15.605 DRIVER resuming send queue 18:16:15.611 DRIVER » [Node 002] [REQ] [RequestNodeInfo] [P: NodeQuery] payload: 0x02 18:16:15.613 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.614 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.606 CNTRLR [Node 008] The node is now awake. 18:16:15.609 CNTRLR [Node 008] Interview stage completed: ProtocolInfo 18:16:15.609 CNTRLR » [Node 008] querying node info... 18:16:15.614 CNTRLR [Node 007] Interview stage completed: NodeInfo 18:16:15.624 CNTRLR [Node 007] ManufacturerSpecificCC: doing a complete interview... 18:16:15.625 CNTRLR » [Node 007] querying manufacturer information... 18:16:15.634 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:15.641 SERIAL « [ACK] (0x06) 18:16:15.641 DRIVER ACK received from controller for current transaction 18:16:15.642 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:15.643 SERIAL « 0x01 (1 bytes) 18:16:15.644 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:15.649 DRIVER « [RES] [RequestNodeInfo] [confirmation] payload: 0x01 18:16:15.646 SERIAL « 0x040160019b (5 bytes) 18:16:15.647 SERIAL Buffer := 0x01040160019b (6 bytes) 18:16:15.648 SERIAL » [ACK] (0x06) 18:16:15.650 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:19.861 SERIAL « 0x01 (1 bytes) 18:16:19.862 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:19.865 DRIVER « [REQ] [ApplicationUpdateRequest] [fatal_node] payload: 0x810000 18:16:19.866 CNTRLR [Node 002] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:16:19.863 SERIAL « 0x06004981000031 (7 bytes) 18:16:19.863 SERIAL Buffer := 0x0106004981000031 (8 bytes) 18:16:19.864 SERIAL » [ACK] (0x06) 18:16:19.869 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:20.368 DRIVER » [Node 002] [REQ] [RequestNodeInfo] [attempt 2/3] payload: 0x02 18:16:20.369 SERIAL » 0x010400600299 (6 bytes) 18:16:20.374 SERIAL « [ACK] (0x06) 18:16:20.375 DRIVER ACK received from controller for current transaction 18:16:20.376 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:20.384 SERIAL « 0x01 (1 bytes) 18:16:20.385 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:20.387 DRIVER « [RES] [RequestNodeInfo] [confirmation] payload: 0x01 18:16:20.386 SERIAL « 0x040160019b (5 bytes) 18:16:20.386 SERIAL Buffer := 0x01040160019b (6 bytes) 18:16:20.387 SERIAL » [ACK] (0x06) 18:16:20.388 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:24.557 SERIAL « 0x01 (1 bytes) 18:16:24.557 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:24.560 DRIVER « [REQ] [ApplicationUpdateRequest] [fatal_node] payload: 0x810000 18:16:24.561 CNTRLR [Node 002] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:16:24.559 SERIAL « 0x06004981000031 (7 bytes) 18:16:24.559 SERIAL Buffer := 0x0106004981000031 (8 bytes) 18:16:24.560 SERIAL » [ACK] (0x06) 18:16:24.562 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.061 DRIVER » [Node 002] [REQ] [RequestNodeInfo] [attempt 3/3] payload: 0x02 18:16:25.063 SERIAL » 0x010400600299 (6 bytes) 18:16:25.067 SERIAL « [ACK] (0x06) 18:16:25.068 DRIVER ACK received from controller for current transaction 18:16:25.070 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.076 SERIAL « 0x01 (1 bytes) 18:16:25.077 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.080 DRIVER « [RES] [RequestNodeInfo] [confirmation] payload: 0x01 18:16:25.078 SERIAL « 0x040160019b (5 bytes) 18:16:25.078 SERIAL Buffer := 0x01040160019b (6 bytes) 18:16:25.079 SERIAL » [ACK] (0x06) 18:16:25.080 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.274 DRIVER The awake timeout for node 2 has elapsed. Assuming it is asleep. 18:16:25.275 CNTRLR [Node 002] The node is now asleep. 18:16:25.281 DRIVER » [Node 007] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 1 └─[ManufacturerSpecificCCGet] 18:16:25.282 SERIAL » 0x01090013070272042501b2 (11 bytes) 18:16:25.286 SERIAL « [ACK] (0x06) 18:16:25.287 DRIVER ACK received from controller for current transaction 18:16:25.287 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.292 SERIAL « 0x01 (1 bytes) 18:16:25.293 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.297 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:25.295 SERIAL « 0x04011301e8 (5 bytes) 18:16:25.295 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:25.296 SERIAL » [ACK] (0x06) 18:16:25.298 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.300 CNTRLR [Node 003] The node is now asleep. 18:16:25.300 DRIVER The awake timeout for node 3 has elapsed. Assuming it is asleep. 18:16:25.303 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:25.309 SERIAL « 0x01 (1 bytes) 18:16:25.309 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.318 DRIVER « [REQ] [SendData] [confirmation] callbackId: 1 transmitStatus: OK 18:16:25.314 SERIAL « 0x07001301000002e8 (8 bytes) 18:16:25.315 SERIAL Buffer := 0x0107001301000002e8 (9 bytes) 18:16:25.316 SERIAL » [ACK] (0x06) 18:16:25.321 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.323 CNTRLR [Node 004] The node is now asleep. 18:16:25.319 DRIVER ACK received from node for current transaction. RTT = 40.20 ms 18:16:25.322 DRIVER The awake timeout for node 4 has elapsed. Assuming it is asleep. 18:16:25.325 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:25.328 SERIAL « 0x010e0004000708720501590001005286 (16 bytes) 18:16:25.333 CNTRLR [Node 007] [+] [Manufacturer Specific] manufacturerId: 345 [Endpoint 0] 18:16:25.348 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[ManufacturerSpecificCCReport] payload: 0x015900010052 18:16:25.328 SERIAL Buffer := 0x010e0004000708720501590001005286 (16 bytes) 18:16:25.347 SERIAL » [ACK] (0x06) 18:16:25.350 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.355 SERIAL » 0x01040060059e (6 bytes) 18:16:25.343 CNTRLR [Node 007] [+] [Manufacturer Specific] productType: 1 [Endpoint 0] 18:16:25.345 CNTRLR [Node 007] [+] [Manufacturer Specific] productId: 82 [Endpoint 0] 18:16:25.351 CNTRLR « [Node 007] received response for manufacturer information: manufacturer: Goap (0x0159) product type: 0x01 product id: 0x52 18:16:25.353 CNTRLR [Node 007] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 18:16:25.357 CNTRLR [Node 005] The node is now asleep. 18:16:25.349 DRIVER ACK already received, resolving transaction 18:16:25.350 DRIVER resuming send queue 18:16:25.355 DRIVER » [Node 005] [REQ] [RequestNodeInfo] [P: NodeQuery] payload: 0x05 18:16:25.356 DRIVER The awake timeout for node 5 has elapsed. Assuming it is asleep. 18:16:25.367 SERIAL » 0x01040060069d (6 bytes) 18:16:25.366 DRIVER » [Node 006] [REQ] [RequestNodeInfo] [P: NodeQuery] payload: 0x06 18:16:25.384 SERIAL « [ACK] (0x06) 18:16:25.385 DRIVER ACK received from controller for current transaction 18:16:25.386 SERIAL « 0x0601040160019b18 (8 bytes) 18:16:25.387 SERIAL Buffer := 0x01040160019b18 (7 bytes) 18:16:25.387 SERIAL » [ACK] (0x06) 18:16:25.389 SERIAL « [CAN] (0x18) 18:16:25.391 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.388 DRIVER « [RES] [RequestNodeInfo] [confirmation] payload: 0x01 18:16:25.391 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 18:16:25.399 CNTRLR [Node 006] The node is now asleep. 18:16:25.398 DRIVER The awake timeout for node 6 has elapsed. Assuming it is asleep. 18:16:25.403 CNTRLR [Node 007] VersionCC: doing a complete interview... 18:16:25.404 CNTRLR » [Node 007] querying node versions... 18:16:25.409 SERIAL » 0x0109001307028611250250 (11 bytes) 18:16:25.408 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 2 └─[VersionCCGet] 18:16:25.410 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:25.414 SERIAL « [ACK] (0x06) 18:16:25.415 DRIVER ACK received from controller for current transaction 18:16:25.415 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.420 SERIAL « 0x01 (1 bytes) 18:16:25.421 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.424 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:25.422 SERIAL « 0x04011301e8 (5 bytes) 18:16:25.423 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:25.423 SERIAL » [ACK] (0x06) 18:16:25.425 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.491 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 2 └─[VersionCCGet] 18:16:25.492 SERIAL » 0x0109001307028611250250 (11 bytes) 18:16:25.504 SERIAL « [ACK] (0x06) 18:16:25.506 DRIVER ACK received from controller for current transaction 18:16:25.507 SERIAL « 0x0601 (2 bytes) 18:16:25.508 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.510 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:25.509 SERIAL « 0x04011301e8 (5 bytes) 18:16:25.509 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:25.510 SERIAL » [ACK] (0x06) 18:16:25.511 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.516 SERIAL « 0x01 (1 bytes) 18:16:25.517 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.522 DRIVER « [REQ] [SendData] [confirmation] callbackId: 2 transmitStatus: OK 18:16:25.520 SERIAL « 0x07001302000001e8 (8 bytes) 18:16:25.520 SERIAL Buffer := 0x0107001302000001e8 (9 bytes) 18:16:25.521 SERIAL » [ACK] (0x06) 18:16:25.524 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.523 DRIVER ACK received from node for current transaction. RTT = 114.90 ms 18:16:25.528 SERIAL « 0x01 (1 bytes) 18:16:25.528 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.532 CNTRLR [Node 007] [+] [Version] libraryType: 3 [Endpoint 0] 18:16:25.540 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[VersionCCReport] payload: 0x030418030102010203 18:16:25.529 SERIAL « 0x11000400070b86120304180301020102036d (18 bytes) 18:16:25.530 SERIAL Buffer := 0x0111000400070b86120304180301020102036d (19 bytes) 18:16:25.539 SERIAL » [ACK] (0x06) 18:16:25.542 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.552 SERIAL » 0x010a0013070386135e25030f (12 bytes) 18:16:25.535 CNTRLR [Node 007] [+] [Version] protocolVersion: "4.24" [Endpoint 0] 18:16:25.537 CNTRLR [Node 007] [+] [Version] firmwareVersions: 3.1 [Endpoint 0] 18:16:25.543 CNTRLR « [Node 007] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 4.24 firmware versions: 3.1 18:16:25.544 CNTRLR » [Node 007] querying CC versions... 18:16:25.545 CNTRLR » [Node 007] querying the CC version for Z-Wave Plus Info (0x5e)... 18:16:25.541 DRIVER ACK already received, resolving transaction 18:16:25.541 DRIVER resuming send queue 18:16:25.551 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 3 └─[VersionCCCommandClassGet] payload: 0x5e 18:16:25.553 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:25.554 SERIAL « 0x0107001302000004ed (9 bytes) 18:16:25.555 SERIAL Buffer := 0x0107001302000004ed (9 bytes) 18:16:25.556 SERIAL » [ACK] (0x06) 18:16:25.558 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.557 DRIVER handling request SendData (19) 18:16:25.557 DRIVER no handlers registered! 18:16:25.561 SERIAL « [CAN] (0x18) 18:16:25.562 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.562 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 18:16:25.570 SERIAL « 0x0111000400070b86120304180301020102036d (19 bytes) 18:16:25.573 CNTRLR [Node 007] [~] [Version] libraryType: 3 => 3 [Endpoint 0] 18:16:25.571 SERIAL Buffer := 0x0111000400070b86120304180301020102036d (19 bytes) 18:16:25.586 SERIAL » [ACK] (0x06) 18:16:25.589 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.577 CNTRLR [Node 007] [~] [Version] protocolVersion: "4.24" => "4.24" [Endpoint 0] 18:16:25.583 CNTRLR [Node 007] [~] [Version] firmwareVersions: 3.1 => 3.1 [Endpoint 0] 18:16:25.607 DRIVER The awake timeout for node 8 has elapsed. Assuming it is asleep. 18:16:25.607 CNTRLR [Node 008] The node is now asleep. 18:16:25.610 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:25.663 DRIVER » [Node 007] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 3 └─[VersionCCCommandClassGet] payload: 0x5e 18:16:25.664 SERIAL » 0x010a0013070386135e25030f (12 bytes) 18:16:25.669 SERIAL « [ACK] (0x06) 18:16:25.670 DRIVER ACK received from controller for current transaction 18:16:25.671 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.675 SERIAL « 0x01 (1 bytes) 18:16:25.676 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.680 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:25.678 SERIAL « 0x04011301e8 (5 bytes) 18:16:25.678 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:25.679 SERIAL » [ACK] (0x06) 18:16:25.681 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.691 SERIAL « 0x01 (1 bytes) 18:16:25.692 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.696 DRIVER « [REQ] [SendData] [confirmation] callbackId: 3 transmitStatus: OK 18:16:25.693 SERIAL « 0x07001303000003eb (8 bytes) 18:16:25.694 SERIAL Buffer := 0x0107001303000003eb (9 bytes) 18:16:25.695 SERIAL » [ACK] (0x06) 18:16:25.699 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.697 DRIVER ACK received from node for current transaction. RTT = 146.88 ms 18:16:25.703 SERIAL « 0x01 (1 bytes) 18:16:25.704 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.708 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x5e02 18:16:25.711 CNTRLR [Node 007] supports CC Z-Wave Plus Info (0x5e) in version 2 18:16:25.705 SERIAL « 0x0a000400070486145e023c (11 bytes) 18:16:25.706 SERIAL Buffer := 0x010a000400070486145e023c (12 bytes) 18:16:25.707 SERIAL » [ACK] (0x06) 18:16:25.710 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.715 SERIAL » 0x010a001307038613862504d0 (12 bytes) 18:16:25.709 DRIVER ACK already received, resolving transaction 18:16:25.709 DRIVER resuming send queue 18:16:25.714 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 4 └─[VersionCCCommandClassGet] payload: 0x86 18:16:25.715 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:25.712 CNTRLR » [Node 007] querying the CC version for Version (0x86)... 18:16:25.720 SERIAL « [ACK] (0x06) 18:16:25.721 DRIVER ACK received from controller for current transaction 18:16:25.722 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.727 SERIAL « 0x01 (1 bytes) 18:16:25.728 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.733 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:25.730 SERIAL « 0x04011301e8 (5 bytes) 18:16:25.731 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:25.732 SERIAL » [ACK] (0x06) 18:16:25.734 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.743 SERIAL « 0x01 (1 bytes) 18:16:25.744 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.747 DRIVER « [REQ] [SendData] [confirmation] callbackId: 4 transmitStatus: OK 18:16:25.746 SERIAL « 0x07001304000002ed (8 bytes) 18:16:25.746 SERIAL Buffer := 0x0107001304000002ed (9 bytes) 18:16:25.746 SERIAL » [ACK] (0x06) 18:16:25.749 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.748 DRIVER ACK received from node for current transaction. RTT = 34.17 ms 18:16:25.754 SERIAL « 0x01 (1 bytes) 18:16:25.755 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.759 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8602 18:16:25.761 CNTRLR [Node 007] supports CC Version (0x86) in version 2 18:16:25.756 SERIAL « 0x0a000400070486148602e4 (11 bytes) 18:16:25.757 SERIAL Buffer := 0x010a000400070486148602e4 (12 bytes) 18:16:25.758 SERIAL » [ACK] (0x06) 18:16:25.761 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.766 SERIAL » 0x010a00130703861372250525 (12 bytes) 18:16:25.759 DRIVER ACK already received, resolving transaction 18:16:25.760 DRIVER resuming send queue 18:16:25.765 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 5 └─[VersionCCCommandClassGet] payload: 0x72 18:16:25.766 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:25.762 CNTRLR [Node 007] skipping query for Device Reset Locally (0x5a) because max implem ented version is 1 18:16:25.763 CNTRLR » [Node 007] querying the CC version for Manufacturer Specific (0x72)... 18:16:25.771 SERIAL « [ACK] (0x06) 18:16:25.771 DRIVER ACK received from controller for current transaction 18:16:25.772 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.778 SERIAL « 0x01 (1 bytes) 18:16:25.778 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.781 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:25.779 SERIAL « 0x04011301e8 (5 bytes) 18:16:25.780 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:25.780 SERIAL » [ACK] (0x06) 18:16:25.782 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.794 SERIAL « 0x01 (1 bytes) 18:16:25.795 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.798 DRIVER « [REQ] [SendData] [confirmation] callbackId: 5 transmitStatus: OK 18:16:25.796 SERIAL « 0x07001305000002ec (8 bytes) 18:16:25.797 SERIAL Buffer := 0x0107001305000002ec (9 bytes) 18:16:25.797 SERIAL » [ACK] (0x06) 18:16:25.799 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.798 DRIVER ACK received from node for current transaction. RTT = 33.73 ms 18:16:25.805 SERIAL « 0x01 (1 bytes) 18:16:25.806 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.809 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x7202 18:16:25.812 CNTRLR [Node 007] supports CC Manufacturer Specific (0x72) in version 2 18:16:25.807 SERIAL « 0x0a00040007048614720210 (11 bytes) 18:16:25.807 SERIAL Buffer := 0x010a00040007048614720210 (12 bytes) 18:16:25.808 SERIAL » [ACK] (0x06) 18:16:25.811 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.816 SERIAL » 0x010a00130703861325250671 (12 bytes) 18:16:25.810 DRIVER ACK already received, resolving transaction 18:16:25.810 DRIVER resuming send queue 18:16:25.816 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 6 └─[VersionCCCommandClassGet] payload: 0x25 18:16:25.817 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:25.812 CNTRLR [Node 007] skipping query for Powerlevel (0x73) because max implemented vers ion is 0 18:16:25.813 CNTRLR [Node 007] skipping query for All Switch (0x27) because max implemented vers ion is 0 18:16:25.814 CNTRLR » [Node 007] querying the CC version for Binary Switch (0x25)... 18:16:25.820 SERIAL « [ACK] (0x06) 18:16:25.821 DRIVER ACK received from controller for current transaction 18:16:25.822 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.827 SERIAL « 0x01 (1 bytes) 18:16:25.829 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.832 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:25.830 SERIAL « 0x04011301e8 (5 bytes) 18:16:25.831 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:25.832 SERIAL » [ACK] (0x06) 18:16:25.833 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.844 SERIAL « 0x01 (1 bytes) 18:16:25.845 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.849 DRIVER « [REQ] [SendData] [confirmation] callbackId: 6 transmitStatus: OK 18:16:25.847 SERIAL « 0x07001306000002ef (8 bytes) 18:16:25.848 SERIAL Buffer := 0x0107001306000002ef (9 bytes) 18:16:25.848 SERIAL » [ACK] (0x06) 18:16:25.851 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.850 DRIVER ACK received from node for current transaction. RTT = 34.31 ms 18:16:25.854 SERIAL « 0x01 (1 bytes) 18:16:25.855 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.858 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x2501 18:16:25.861 CNTRLR [Node 007] supports CC Binary Switch (0x25) in version 1 18:16:25.856 SERIAL « 0x0a00040007048614250144 (11 bytes) 18:16:25.857 SERIAL Buffer := 0x010a00040007048614250144 (12 bytes) 18:16:25.858 SERIAL » [ACK] (0x06) 18:16:25.860 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.865 SERIAL » 0x010a00130703861326250773 (12 bytes) 18:16:25.859 DRIVER ACK already received, resolving transaction 18:16:25.860 DRIVER resuming send queue 18:16:25.864 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 7 └─[VersionCCCommandClassGet] payload: 0x26 18:16:25.865 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:25.862 CNTRLR » [Node 007] querying the CC version for Multilevel Switch (0x26)... 18:16:25.876 SERIAL « [ACK] (0x06) 18:16:25.876 DRIVER ACK received from controller for current transaction 18:16:25.877 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.882 SERIAL « 0x01 (1 bytes) 18:16:25.883 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.887 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:25.885 SERIAL « 0x04011301e8 (5 bytes) 18:16:25.886 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:25.886 SERIAL » [ACK] (0x06) 18:16:25.888 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.898 SERIAL « 0x01 (1 bytes) 18:16:25.899 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.902 DRIVER « [REQ] [SendData] [confirmation] callbackId: 7 transmitStatus: OK 18:16:25.900 SERIAL « 0x07001307000002ee (8 bytes) 18:16:25.901 SERIAL Buffer := 0x0107001307000002ee (9 bytes) 18:16:25.901 SERIAL » [ACK] (0x06) 18:16:25.903 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.902 DRIVER ACK received from node for current transaction. RTT = 38.84 ms 18:16:25.910 SERIAL « 0x01 (1 bytes) 18:16:25.911 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.914 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x2603 18:16:25.916 CNTRLR [Node 007] supports CC Multilevel Switch (0x26) in version 3 18:16:25.912 SERIAL « 0x0a00040007048614260345 (11 bytes) 18:16:25.912 SERIAL Buffer := 0x010a00040007048614260345 (12 bytes) 18:16:25.913 SERIAL » [ACK] (0x06) 18:16:25.916 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.920 SERIAL » 0x010a00130703861332250868 (12 bytes) 18:16:25.915 DRIVER ACK already received, resolving transaction 18:16:25.915 DRIVER resuming send queue 18:16:25.919 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 8 └─[VersionCCCommandClassGet] payload: 0x32 18:16:25.920 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:25.917 CNTRLR » [Node 007] querying the CC version for Meter (0x32)... 18:16:25.924 SERIAL « [ACK] (0x06) 18:16:25.928 DRIVER ACK received from controller for current transaction 18:16:25.928 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.930 SERIAL « 0x01 (1 bytes) 18:16:25.930 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.933 SERIAL « 0x04011301e8 (5 bytes) 18:16:25.936 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:25.934 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:25.935 SERIAL » [ACK] (0x06) 18:16:25.936 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.946 SERIAL « 0x01 (1 bytes) 18:16:25.947 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.953 DRIVER « [REQ] [SendData] [confirmation] callbackId: 8 transmitStatus: OK 18:16:25.948 SERIAL « 0x07001308000002e1 (8 bytes) 18:16:25.952 SERIAL Buffer := 0x0107001308000002e1 (9 bytes) 18:16:25.953 SERIAL » [ACK] (0x06) 18:16:25.955 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.954 DRIVER ACK received from node for current transaction. RTT = 35.37 ms 18:16:25.958 SERIAL « 0x01 (1 bytes) 18:16:25.959 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.965 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x3204 18:16:25.968 CNTRLR [Node 007] supports CC Meter (0x32) in version 4 18:16:25.960 SERIAL « 0x0a00040007048614320456 (11 bytes) 18:16:25.962 SERIAL Buffer := 0x010a00040007048614320456 (12 bytes) 18:16:25.962 SERIAL » [ACK] (0x06) 18:16:25.967 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.971 SERIAL » 0x010a0013070386137125092a (12 bytes) 18:16:25.966 DRIVER ACK already received, resolving transaction 18:16:25.967 DRIVER resuming send queue 18:16:25.971 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 9 └─[VersionCCCommandClassGet] payload: 0x71 18:16:25.972 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:25.969 CNTRLR » [Node 007] querying the CC version for Notification (0x71)... 18:16:25.976 SERIAL « [ACK] (0x06) 18:16:25.976 DRIVER ACK received from controller for current transaction 18:16:25.977 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.982 SERIAL « 0x01 (1 bytes) 18:16:25.983 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:25.985 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:25.984 SERIAL « 0x04011301e8 (5 bytes) 18:16:25.984 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:25.984 SERIAL » [ACK] (0x06) 18:16:25.986 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:25.998 SERIAL « 0x01 (1 bytes) 18:16:25.999 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.004 DRIVER « [REQ] [SendData] [confirmation] callbackId: 9 transmitStatus: OK 18:16:26.002 SERIAL « 0x07001309000002e0 (8 bytes) 18:16:26.002 SERIAL Buffer := 0x0107001309000002e0 (9 bytes) 18:16:26.003 SERIAL » [ACK] (0x06) 18:16:26.005 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.004 DRIVER ACK received from node for current transaction. RTT = 34.00 ms 18:16:26.010 SERIAL « 0x01 (1 bytes) 18:16:26.011 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.015 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x7105 18:16:26.017 CNTRLR [Node 007] supports CC Notification (0x71) in version 5 18:16:26.012 SERIAL « 0x0a00040007048614710514 (11 bytes) 18:16:26.013 SERIAL Buffer := 0x010a00040007048614710514 (12 bytes) 18:16:26.014 SERIAL » [ACK] (0x06) 18:16:26.016 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.020 SERIAL » 0x010a00130703861385250add (12 bytes) 18:16:26.015 DRIVER ACK already received, resolving transaction 18:16:26.016 DRIVER resuming send queue 18:16:26.019 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 10 └─[VersionCCCommandClassGet] payload: 0x85 18:16:26.020 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:26.017 CNTRLR » [Node 007] querying the CC version for Association (0x85)... 18:16:26.024 SERIAL « [ACK] (0x06) 18:16:26.025 DRIVER ACK received from controller for current transaction 18:16:26.025 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.030 SERIAL « 0x01 (1 bytes) 18:16:26.031 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.034 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:26.032 SERIAL « 0x04011301e8 (5 bytes) 18:16:26.033 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:26.033 SERIAL » [ACK] (0x06) 18:16:26.035 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.046 SERIAL « 0x01 (1 bytes) 18:16:26.047 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.050 DRIVER « [REQ] [SendData] [confirmation] callbackId: 10 transmitStatus: OK 18:16:26.048 SERIAL « 0x0700130a000002e3 (8 bytes) 18:16:26.049 SERIAL Buffer := 0x010700130a000002e3 (9 bytes) 18:16:26.049 SERIAL » [ACK] (0x06) 18:16:26.052 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.051 DRIVER ACK received from node for current transaction. RTT = 31.82 ms 18:16:26.058 SERIAL « 0x01 (1 bytes) 18:16:26.059 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.063 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8502 18:16:26.065 CNTRLR [Node 007] supports CC Association (0x85) in version 2 18:16:26.060 SERIAL « 0x0a000400070486148502e7 (11 bytes) 18:16:26.061 SERIAL Buffer := 0x010a000400070486148502e7 (12 bytes) 18:16:26.062 SERIAL » [ACK] (0x06) 18:16:26.065 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.068 SERIAL » 0x010a0013070386138e250bd7 (12 bytes) 18:16:26.064 DRIVER ACK already received, resolving transaction 18:16:26.064 DRIVER resuming send queue 18:16:26.068 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 11 └─[VersionCCCommandClassGet] payload: 0x8e 18:16:26.069 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:26.066 CNTRLR » [Node 007] querying the CC version for Multi Channel Association (0x8e)... 18:16:26.074 SERIAL « [ACK] (0x06) 18:16:26.074 DRIVER ACK received from controller for current transaction 18:16:26.075 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.080 SERIAL « 0x01 (1 bytes) 18:16:26.081 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.084 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:26.082 SERIAL « 0x04011301e8 (5 bytes) 18:16:26.083 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:26.084 SERIAL » [ACK] (0x06) 18:16:26.085 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.096 SERIAL « 0x010700130b000002e2 (9 bytes) 18:16:26.098 DRIVER « [REQ] [SendData] [confirmation] callbackId: 11 transmitStatus: OK 18:16:26.097 SERIAL Buffer := 0x010700130b000002e2 (9 bytes) 18:16:26.097 SERIAL » [ACK] (0x06) 18:16:26.100 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.099 DRIVER ACK received from node for current transaction. RTT = 31.51 ms 18:16:26.109 SERIAL « 0x01 (1 bytes) 18:16:26.110 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.113 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8e03 18:16:26.115 CNTRLR [Node 007] supports CC Multi Channel Association (0x8e) in version 3 18:16:26.111 SERIAL « 0x0a000400070486148e03ed (11 bytes) 18:16:26.111 SERIAL Buffer := 0x010a000400070486148e03ed (12 bytes) 18:16:26.112 SERIAL » [ACK] (0x06) 18:16:26.115 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.118 SERIAL » 0x010a00130703861359250c07 (12 bytes) 18:16:26.114 DRIVER ACK already received, resolving transaction 18:16:26.114 DRIVER resuming send queue 18:16:26.118 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 12 └─[VersionCCCommandClassGet] payload: 0x59 18:16:26.119 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:26.116 CNTRLR » [Node 007] querying the CC version for Association Group Information (0x59). .. 18:16:26.124 SERIAL « [ACK] (0x06) 18:16:26.125 DRIVER ACK received from controller for current transaction 18:16:26.125 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.131 SERIAL « 0x01 (1 bytes) 18:16:26.131 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.134 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:26.132 SERIAL « 0x04011301e8 (5 bytes) 18:16:26.133 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:26.133 SERIAL » [ACK] (0x06) 18:16:26.134 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.147 SERIAL « 0x01 (1 bytes) 18:16:26.147 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.150 DRIVER « [REQ] [SendData] [confirmation] callbackId: 12 transmitStatus: OK 18:16:26.148 SERIAL « 0x0700130c000002e5 (8 bytes) 18:16:26.149 SERIAL Buffer := 0x010700130c000002e5 (9 bytes) 18:16:26.149 SERIAL » [ACK] (0x06) 18:16:26.151 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.150 DRIVER ACK received from node for current transaction. RTT = 32.91 ms 18:16:26.158 SERIAL « 0x01 (1 bytes) 18:16:26.159 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.162 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x5902 18:16:26.165 CNTRLR [Node 007] supports CC Association Group Information (0x59) in version 2 18:16:26.160 SERIAL « 0x0a0004000704861459023b (11 bytes) 18:16:26.161 SERIAL Buffer := 0x010a0004000704861459023b (12 bytes) 18:16:26.161 SERIAL » [ACK] (0x06) 18:16:26.164 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.163 DRIVER ACK already received, resolving transaction 18:16:26.163 DRIVER resuming send queue 18:16:26.167 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 13 └─[VersionCCCommandClassGet] payload: 0x70 18:16:26.168 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:26.165 CNTRLR » [Node 007] querying the CC version for Configuration (0x70)... 18:16:26.168 SERIAL » 0x010a00130703861370250d2f (12 bytes) 18:16:26.172 SERIAL « [ACK] (0x06) 18:16:26.172 DRIVER ACK received from controller for current transaction 18:16:26.173 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.178 SERIAL « 0x01 (1 bytes) 18:16:26.179 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.181 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:26.180 SERIAL « 0x04011301e8 (5 bytes) 18:16:26.180 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:26.181 SERIAL » [ACK] (0x06) 18:16:26.182 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.194 SERIAL « 0x01 (1 bytes) 18:16:26.195 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.197 DRIVER « [REQ] [SendData] [confirmation] callbackId: 13 transmitStatus: OK 18:16:26.196 SERIAL « 0x0700130d000002e4 (8 bytes) 18:16:26.196 SERIAL Buffer := 0x010700130d000002e4 (9 bytes) 18:16:26.197 SERIAL » [ACK] (0x06) 18:16:26.199 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.198 DRIVER ACK received from node for current transaction. RTT = 30.96 ms 18:16:26.206 SERIAL « 0x01 (1 bytes) 18:16:26.207 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.210 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x7001 18:16:26.213 CNTRLR [Node 007] supports CC Configuration (0x70) in version 1 18:16:26.208 SERIAL « 0x0a00040007048614700111 (11 bytes) 18:16:26.209 SERIAL Buffer := 0x010a00040007048614700111 (12 bytes) 18:16:26.209 SERIAL » [ACK] (0x06) 18:16:26.213 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.211 DRIVER ACK already received, resolving transaction 18:16:26.212 DRIVER resuming send queue 18:16:26.222 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:16:26.223 DRIVER Send queue: (6 messages) · [REQ] RequestNodeInfo [Node 2, asleep] · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 4, asleep] · [REQ] RequestNodeInfo [Node 5, asleep] · [REQ] RequestNodeInfo [Node 6, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] 18:16:26.215 CNTRLR [Node 007] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 18:16:26.217 CNTRLR [Node 007] trying to load device config 18:16:26.247 CNTRLR [Node 007] device config loaded 18:16:26.258 CNTRLR [Node 007] ZWavePlusCC: doing a complete interview... 18:16:26.261 DRIVER » [Node 007] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 14 └─[ZWavePlusCCGet] 18:16:26.262 SERIAL » 0x0109001307025e01250e94 (11 bytes) 18:16:26.259 CNTRLR » [Node 007] querying Z-Wave+ information... 18:16:26.266 SERIAL « [ACK] (0x06) 18:16:26.267 DRIVER ACK received from controller for current transaction 18:16:26.268 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.273 SERIAL « 0x01 (1 bytes) 18:16:26.273 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.276 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:26.274 SERIAL « 0x04011301e8 (5 bytes) 18:16:26.275 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:26.275 SERIAL » [ACK] (0x06) 18:16:26.276 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.289 SERIAL « 0x01 (1 bytes) 18:16:26.290 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.293 DRIVER « [REQ] [SendData] [confirmation] callbackId: 14 transmitStatus: OK 18:16:26.291 SERIAL « 0x0700130e000002e7 (8 bytes) 18:16:26.292 SERIAL Buffer := 0x010700130e000002e7 (9 bytes) 18:16:26.292 SERIAL » [ACK] (0x06) 18:16:26.294 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.293 DRIVER ACK received from node for current transaction. RTT = 32.15 ms 18:16:26.301 SERIAL « 0x01 (1 bytes) 18:16:26.302 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.306 CNTRLR [Node 007] [+] [Z-Wave Plus Info] zwavePlusVersion: 1 [Endpoint 0] 18:16:26.318 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[ZWavePlusCCReport] payload: 0x0105001c001c00 18:16:26.303 SERIAL « 0x0f00040007095e020105001c001c00a2 (16 bytes) 18:16:26.304 SERIAL Buffer := 0x010f00040007095e020105001c001c00a2 (17 bytes) 18:16:26.317 SERIAL » [ACK] (0x06) 18:16:26.320 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.329 SERIAL » 0x0109001307022502250fed (11 bytes) 18:16:26.319 DRIVER ACK already received, resolving transaction 18:16:26.320 DRIVER resuming send queue 18:16:26.329 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 15 └─[BinarySwitchCCGet] 18:16:26.330 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:26.309 CNTRLR [Node 007] [+] [Z-Wave Plus Info] nodeType: 0 [Endpoint 0] 18:16:26.311 CNTRLR [Node 007] [+] [Z-Wave Plus Info] roleType: 5 [Endpoint 0] 18:16:26.313 CNTRLR [Node 007] [+] [Z-Wave Plus Info] installerIcon: 7168 [Endpoint 0] 18:16:26.315 CNTRLR [Node 007] [+] [Z-Wave Plus Info] userIcon: 7168 [Endpoint 0] 18:16:26.321 CNTRLR « [Node 007] received response for Z-Wave+ information: Z-Wave+ version: 1 role type: AlwaysOnSlave node type: Node installer icon: 0x1c00 user icon: 0x1c00 18:16:26.322 CNTRLR [Node 007] [+] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue 18:16:26.325 CNTRLR [Node 007] BinarySwitchCC: doing a complete interview... 18:16:26.326 CNTRLR » [Node 007] querying Binary Switch state... 18:16:26.340 SERIAL « [ACK] (0x06) 18:16:26.341 DRIVER ACK received from controller for current transaction 18:16:26.342 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.346 SERIAL « 0x01 (1 bytes) 18:16:26.347 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.354 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:26.352 SERIAL « 0x04011301e8 (5 bytes) 18:16:26.352 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:26.353 SERIAL » [ACK] (0x06) 18:16:26.354 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.360 SERIAL « 0x010700130f000002e6 (9 bytes) 18:16:26.362 DRIVER « [REQ] [SendData] [confirmation] callbackId: 15 transmitStatus: OK 18:16:26.360 SERIAL Buffer := 0x010700130f000002e6 (9 bytes) 18:16:26.361 SERIAL » [ACK] (0x06) 18:16:26.364 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.363 DRIVER ACK received from node for current transaction. RTT = 34.53 ms 18:16:26.389 SERIAL « 0x01 (1 bytes) 18:16:26.389 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.395 CNTRLR [Node 007] [+] [Binary Switch] currentValue: false [Endpoint 0] 18:16:26.398 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[BinarySwitchCCReport] payload: 0x00 18:16:26.390 SERIAL « 0x090004000703250300d0 (10 bytes) 18:16:26.391 SERIAL Buffer := 0x01090004000703250300d0 (11 bytes) 18:16:26.397 SERIAL » [ACK] (0x06) 18:16:26.401 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.409 SERIAL » 0x01090013070226062510f5 (11 bytes) 18:16:26.402 CNTRLR « [Node 007] received Binary Switch state: current value: false 18:16:26.403 CNTRLR [Node 007] [+] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] 18:16:26.405 CNTRLR [Node 007] MultilevelSwitchCC: doing a complete interview... 18:16:26.406 CNTRLR » [Node 007] requesting switch type... 18:16:26.399 DRIVER ACK already received, resolving transaction 18:16:26.400 DRIVER resuming send queue 18:16:26.409 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 16 └─[MultilevelSwitchCCSupportedGet] 18:16:26.410 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:26.413 SERIAL « [ACK] (0x06) 18:16:26.414 DRIVER ACK received from controller for current transaction 18:16:26.415 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.421 SERIAL « 0x01 (1 bytes) 18:16:26.421 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.424 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:26.422 SERIAL « 0x04011301e8 (5 bytes) 18:16:26.423 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:26.423 SERIAL » [ACK] (0x06) 18:16:26.425 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.440 SERIAL « 0x01 (1 bytes) 18:16:26.440 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.443 DRIVER « [REQ] [SendData] [confirmation] callbackId: 16 transmitStatus: OK 18:16:26.441 SERIAL « 0x07001310000002f9 (8 bytes) 18:16:26.442 SERIAL Buffer := 0x0107001310000002f9 (9 bytes) 18:16:26.442 SERIAL » [ACK] (0x06) 18:16:26.445 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.444 DRIVER ACK received from node for current transaction. RTT = 35.42 ms 18:16:26.658 SERIAL « 0x01 (1 bytes) 18:16:26.659 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.662 DRIVER no handlers registered! 18:16:26.660 SERIAL « 0x06004981000031 (7 bytes) 18:16:26.661 SERIAL Buffer := 0x0106004981000031 (8 bytes) 18:16:26.661 SERIAL » [ACK] (0x06) 18:16:26.662 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.665 SERIAL « 0x01 (1 bytes) 18:16:26.665 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.668 DRIVER no handlers registered! 18:16:26.666 SERIAL « 0x06004981000031 (7 bytes) 18:16:26.667 SERIAL Buffer := 0x0106004981000031 (8 bytes) 18:16:26.668 SERIAL » [ACK] (0x06) 18:16:26.669 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.671 SERIAL « 0x01 (1 bytes) 18:16:26.672 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.685 CNTRLR [Node 007] [+] [Multilevel Switch] switchType: 2 [Endpoint 0] [internal] 18:16:26.693 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[MultilevelSwitchCCSupportedReport] payload: 0x0200 18:16:26.682 SERIAL « 0x0a000400070426070200d1 (11 bytes) 18:16:26.683 SERIAL Buffer := 0x010a000400070426070200d1 (12 bytes) 18:16:26.692 SERIAL » [ACK] (0x06) 18:16:26.694 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.687 CNTRLR [Node 007] [Multilevel Switch] Down: metadata updated [Endpoint 0] 18:16:26.691 CNTRLR [Node 007] [Multilevel Switch] Up: metadata updated [Endpoint 0] 18:16:26.695 CNTRLR « [Node 007] has switch type Down/Up 18:16:26.695 CNTRLR » [Node 007] requesting current switch state... 18:16:26.694 DRIVER ACK already received, resolving transaction 18:16:26.694 DRIVER resuming send queue 18:16:26.698 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 17 └─[MultilevelSwitchCCGet] 18:16:26.699 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:26.699 SERIAL » 0x01090013070226022511f0 (11 bytes) 18:16:26.700 SERIAL « 0x010a000400070426070200d1 (12 bytes) 18:16:26.701 SERIAL Buffer := 0x010a000400070426070200d1 (12 bytes) 18:16:26.706 SERIAL » [ACK] (0x06) 18:16:26.707 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.702 CNTRLR [Node 007] [~] [Multilevel Switch] switchType: 2 => 2 [Endpoint 0] [internal] 18:16:26.703 CNTRLR [Node 007] [Multilevel Switch] Down: metadata updated [Endpoint 0] 18:16:26.705 CNTRLR [Node 007] [Multilevel Switch] Up: metadata updated [Endpoint 0] 18:16:26.711 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 18:16:26.711 SERIAL « [CAN] (0x18) 18:16:26.712 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.813 DRIVER » [Node 007] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 17 └─[MultilevelSwitchCCGet] 18:16:26.813 SERIAL » 0x01090013070226022511f0 (11 bytes) 18:16:26.817 SERIAL « [ACK] (0x06) 18:16:26.818 DRIVER ACK received from controller for current transaction 18:16:26.818 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.824 SERIAL « 0x01 (1 bytes) 18:16:26.824 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.827 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:26.826 SERIAL « 0x04011301e8 (5 bytes) 18:16:26.826 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:26.826 SERIAL » [ACK] (0x06) 18:16:26.828 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.840 SERIAL « 0x01 (1 bytes) 18:16:26.840 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.843 DRIVER « [REQ] [SendData] [confirmation] callbackId: 17 transmitStatus: OK 18:16:26.841 SERIAL « 0x07001311000002f8 (8 bytes) 18:16:26.842 SERIAL Buffer := 0x0107001311000002f8 (9 bytes) 18:16:26.842 SERIAL » [ACK] (0x06) 18:16:26.844 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.843 DRIVER ACK received from node for current transaction. RTT = 145.43 ms 18:16:26.873 SERIAL « 0x01 (1 bytes) 18:16:26.873 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.875 SERIAL « 0x090004000703260300d3 (10 bytes) 18:16:26.880 CNTRLR [Node 007] [+] [Multilevel Switch] currentValue: 0 [Endpoint 0] 18:16:26.882 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[MultilevelSwitchCCReport] payload: 0x00 18:16:26.876 SERIAL Buffer := 0x01090004000703260300d3 (11 bytes) 18:16:26.881 SERIAL » [ACK] (0x06) 18:16:26.884 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.885 CNTRLR [Node 007] [+] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true 18:16:26.883 DRIVER ACK already received, resolving transaction 18:16:26.883 DRIVER resuming send queue 18:16:26.886 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:16:26.886 DRIVER Send queue: (6 messages) · [REQ] RequestNodeInfo [Node 2, asleep] · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 4, asleep] · [REQ] RequestNodeInfo [Node 5, asleep] · [REQ] RequestNodeInfo [Node 6, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] 18:16:26.900 CNTRLR [Node 007] MeterCC: doing a complete interview... 18:16:26.904 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 18 └─[MeterCCSupportedGet] 18:16:26.905 SERIAL » 0x01090013070232032512e6 (11 bytes) 18:16:26.901 CNTRLR » [Node 007] querying meter support... 18:16:26.909 SERIAL « [ACK] (0x06) 18:16:26.910 DRIVER ACK received from controller for current transaction 18:16:26.911 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.916 SERIAL « 0x01 (1 bytes) 18:16:26.916 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.919 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:26.918 SERIAL « 0x04011301e8 (5 bytes) 18:16:26.918 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:26.918 SERIAL » [ACK] (0x06) 18:16:26.919 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.931 SERIAL « 0x01 (1 bytes) 18:16:26.932 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.934 DRIVER « [REQ] [SendData] [confirmation] callbackId: 18 transmitStatus: OK 18:16:26.933 SERIAL « 0x07001312000003fa (8 bytes) 18:16:26.933 SERIAL Buffer := 0x0107001312000003fa (9 bytes) 18:16:26.933 SERIAL » [ACK] (0x06) 18:16:26.935 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.934 DRIVER ACK received from node for current transaction. RTT = 30.45 ms 18:16:26.944 SERIAL « 0x01 (1 bytes) 18:16:26.945 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.949 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[MeterCCSupportedReport] payload: 0xa105 18:16:26.952 CNTRLR « [Node 007] received meter support: type: Electric supported scales: · kWh, · W supported rate types: · Consumed supports reset: true 18:16:26.946 SERIAL « 0x0a00040007043204a10560 (11 bytes) 18:16:26.946 SERIAL Buffer := 0x010a00040007043204a10560 (12 bytes) 18:16:26.948 SERIAL » [ACK] (0x06) 18:16:26.950 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.956 SERIAL » 0x010a001307033201402513a7 (12 bytes) 18:16:26.949 DRIVER ACK already received, resolving transaction 18:16:26.950 DRIVER resuming send queue 18:16:26.956 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 19 └─[MeterCCGet] payload: 0x40 18:16:26.956 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:26.952 CNTRLR » [Node 007] querying meter value (type = Electric, scale = kWh, rate type = Con sumed)... 18:16:26.960 SERIAL « [ACK] (0x06) 18:16:26.961 DRIVER ACK received from controller for current transaction 18:16:26.961 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.967 SERIAL « 0x01 (1 bytes) 18:16:26.967 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.970 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:26.969 SERIAL « 0x04011301e8 (5 bytes) 18:16:26.969 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:26.969 SERIAL » [ACK] (0x06) 18:16:26.971 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:26.984 SERIAL « 0x01 (1 bytes) 18:16:26.984 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:26.988 DRIVER « [REQ] [SendData] [confirmation] callbackId: 19 transmitStatus: OK 18:16:26.988 DRIVER ACK received from node for current transaction. RTT = 33.54 ms 18:16:26.986 SERIAL « 0x07001313000002fa (8 bytes) 18:16:26.986 SERIAL Buffer := 0x0107001313000002fa (9 bytes) 18:16:26.987 SERIAL » [ACK] (0x06) 18:16:26.989 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.043 SERIAL « 0x01 (1 bytes) 18:16:27.043 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.049 CNTRLR [Node 007] [Meter] value[65537]: metadata updated [Endpoint 0] 18:16:27.058 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[MeterCCReport] payload: 0x2124000003670000 18:16:27.044 SERIAL « 0x10000400070a32022124000003670000b7 (17 bytes) 18:16:27.045 SERIAL Buffer := 0x0110000400070a32022124000003670000b7 (18 bytes) 18:16:27.057 SERIAL » [ACK] (0x06) 18:16:27.059 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.063 SERIAL » 0x010a001307033201502514b0 (12 bytes) 18:16:27.051 CNTRLR [Node 007] [+] [Meter] value[65537]: 87.1 [Endpoint 0] 18:16:27.054 CNTRLR [Node 007] [Meter] deltaTime[65537]: metadata updated [Endpoint 0] 18:16:27.056 CNTRLR [Node 007] [+] [Meter] deltaTime[65537]: 0 [Endpoint 0] 18:16:27.060 CNTRLR » [Node 007] querying meter value (type = Electric, scale = W, rate type = Consu med)... 18:16:27.058 DRIVER ACK already received, resolving transaction 18:16:27.059 DRIVER resuming send queue 18:16:27.062 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 20 └─[MeterCCGet] payload: 0x50 18:16:27.063 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:27.076 SERIAL « [ACK] (0x06) 18:16:27.077 DRIVER ACK received from controller for current transaction 18:16:27.077 SERIAL « 0x0601 (2 bytes) 18:16:27.078 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.082 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:27.080 SERIAL « 0x04011301e8 (5 bytes) 18:16:27.080 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:27.081 SERIAL » [ACK] (0x06) 18:16:27.082 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.090 SERIAL « 0x01 (1 bytes) 18:16:27.091 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.095 DRIVER « [REQ] [SendData] [confirmation] callbackId: 20 transmitStatus: OK 18:16:27.092 SERIAL « 0x07001314000002fd (8 bytes) 18:16:27.092 SERIAL Buffer := 0x0107001314000002fd (9 bytes) 18:16:27.094 SERIAL » [ACK] (0x06) 18:16:27.097 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.096 DRIVER ACK received from node for current transaction. RTT = 34.00 ms 18:16:27.141 SERIAL « 0x01 (1 bytes) 18:16:27.142 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.145 CNTRLR [Node 007] [Meter] value[66049]: metadata updated [Endpoint 0] 18:16:27.152 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[MeterCCReport] payload: 0x2134000000000000 18:16:27.143 SERIAL « 0x10000400070a32022134000000000000c3 (17 bytes) 18:16:27.143 SERIAL Buffer := 0x0110000400070a32022134000000000000c3 (18 bytes) 18:16:27.151 SERIAL » [ACK] (0x06) 18:16:27.153 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.152 DRIVER ACK already received, resolving transaction 18:16:27.153 DRIVER resuming send queue 18:16:27.155 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:16:27.156 DRIVER Send queue: (6 messages) · [REQ] RequestNodeInfo [Node 2, asleep] · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 4, asleep] · [REQ] RequestNodeInfo [Node 5, asleep] · [REQ] RequestNodeInfo [Node 6, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] 18:16:27.146 CNTRLR [Node 007] [+] [Meter] value[66049]: 0 [Endpoint 0] 18:16:27.148 CNTRLR [Node 007] [Meter] deltaTime[66049]: metadata updated [Endpoint 0] 18:16:27.150 CNTRLR [Node 007] [+] [Meter] deltaTime[66049]: 0 [Endpoint 0] 18:16:27.154 CNTRLR [Node 007] [+] [Meter] interviewComplete: true [Endpoint 0] [internal] 18:16:27.178 CNTRLR [Node 007] ConfigurationCC: Loading configuration parameters from device confi g 18:16:27.226 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 21 └─[ConfigurationCCGet] payload: 0x01 18:16:27.226 SERIAL » 0x010a001307037005012515a6 (12 bytes) 18:16:27.181 CNTRLR [Node 007] [+] [Configuration] isParamInformationFromConfig: false [internal] 18:16:27.184 CNTRLR [Node 007] [Configuration] 1: metadata updated 18:16:27.187 CNTRLR [Node 007] [Configuration] 5: metadata updated 18:16:27.190 CNTRLR [Node 007] [Configuration] 10: metadata updated 18:16:27.192 CNTRLR [Node 007] [Configuration] 11: metadata updated 18:16:27.194 CNTRLR [Node 007] [Configuration] 12: metadata updated 18:16:27.196 CNTRLR [Node 007] [Configuration] 21: metadata updated 18:16:27.198 CNTRLR [Node 007] [Configuration] 30: metadata updated 18:16:27.200 CNTRLR [Node 007] [Configuration] 40: metadata updated 18:16:27.203 CNTRLR [Node 007] [Configuration] 42: metadata updated 18:16:27.205 CNTRLR [Node 007] [Configuration] 60: metadata updated 18:16:27.207 CNTRLR [Node 007] [Configuration] 61: metadata updated 18:16:27.209 CNTRLR [Node 007] [Configuration] 65: metadata updated 18:16:27.211 CNTRLR [Node 007] [Configuration] 66: metadata updated 18:16:27.214 CNTRLR [Node 007] [Configuration] 67: metadata updated 18:16:27.216 CNTRLR [Node 007] [Configuration] 68: metadata updated 18:16:27.218 CNTRLR [Node 007] [Configuration] 110: metadata updated 18:16:27.219 CNTRLR [Node 007] [Configuration] 120: metadata updated 18:16:27.221 CNTRLR [Node 007] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 18:16:27.223 CNTRLR » [Node 007] querying parameter #1 value... 18:16:27.239 SERIAL « [ACK] (0x06) 18:16:27.240 DRIVER ACK received from controller for current transaction 18:16:27.240 SERIAL « 0x0601 (2 bytes) 18:16:27.241 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.244 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:27.243 SERIAL « 0x04011301e8 (5 bytes) 18:16:27.243 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:27.244 SERIAL » [ACK] (0x06) 18:16:27.245 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.269 SERIAL « 0x0107001315000002fc (9 bytes) 18:16:27.273 DRIVER « [REQ] [SendData] [confirmation] callbackId: 21 transmitStatus: OK 18:16:27.270 SERIAL Buffer := 0x0107001315000002fc (9 bytes) 18:16:27.272 SERIAL » [ACK] (0x06) 18:16:27.275 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.274 DRIVER ACK received from node for current transaction. RTT = 48.85 ms 18:16:27.293 SERIAL « 0x01 (1 bytes) 18:16:27.296 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.305 CNTRLR [Node 007] [+] [Configuration] 1: 1 18:16:27.309 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x010101 18:16:27.297 SERIAL « 0x0b0004000705700601010185 (12 bytes) 18:16:27.298 SERIAL Buffer := 0x010b0004000705700601010185 (13 bytes) 18:16:27.308 SERIAL » [ACK] (0x06) 18:16:27.313 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.318 SERIAL » 0x010a001307037005052516a1 (12 bytes) 18:16:27.314 CNTRLR » [Node 007] querying parameter #5 value... 18:16:27.311 DRIVER ACK already received, resolving transaction 18:16:27.312 DRIVER resuming send queue 18:16:27.317 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 22 └─[ConfigurationCCGet] payload: 0x05 18:16:27.319 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:27.328 SERIAL « [ACK] (0x06) 18:16:27.329 DRIVER ACK received from controller for current transaction 18:16:27.330 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.340 SERIAL « 0x0104011301e8 (6 bytes) 18:16:27.341 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:27.340 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:27.341 SERIAL » [ACK] (0x06) 18:16:27.342 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.350 SERIAL « 0x01 (1 bytes) 18:16:27.351 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.354 DRIVER « [REQ] [SendData] [confirmation] callbackId: 22 transmitStatus: OK 18:16:27.353 SERIAL « 0x07001316000002ff (8 bytes) 18:16:27.353 SERIAL Buffer := 0x0107001316000002ff (9 bytes) 18:16:27.353 SERIAL » [ACK] (0x06) 18:16:27.356 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.355 DRIVER ACK received from node for current transaction. RTT = 37.80 ms 18:16:27.390 SERIAL « 0x01 (1 bytes) 18:16:27.390 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.391 SERIAL « 0x0b0004000705700605010080 (12 bytes) 18:16:27.393 CNTRLR [Node 007] [+] [Configuration] 5: 0 18:16:27.395 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x050100 18:16:27.392 SERIAL Buffer := 0x010b0004000705700605010080 (13 bytes) 18:16:27.395 SERIAL » [ACK] (0x06) 18:16:27.397 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.399 SERIAL » 0x010a0013070370050a2517af (12 bytes) 18:16:27.397 CNTRLR » [Node 007] querying parameter #10 value... 18:16:27.396 DRIVER ACK already received, resolving transaction 18:16:27.396 DRIVER resuming send queue 18:16:27.399 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 23 └─[ConfigurationCCGet] payload: 0x0a 18:16:27.400 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:27.404 SERIAL « [ACK] (0x06) 18:16:27.404 DRIVER ACK received from controller for current transaction 18:16:27.405 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.414 SERIAL « 0x0104011301e8 (6 bytes) 18:16:27.417 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:27.416 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:27.416 SERIAL » [ACK] (0x06) 18:16:27.418 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.426 SERIAL « 0x01 (1 bytes) 18:16:27.427 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.429 SERIAL « 0x07001317000002fe (8 bytes) 18:16:27.430 DRIVER « [REQ] [SendData] [confirmation] callbackId: 23 transmitStatus: OK 18:16:27.429 SERIAL Buffer := 0x0107001317000002fe (9 bytes) 18:16:27.430 SERIAL » [ACK] (0x06) 18:16:27.432 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.431 DRIVER ACK received from node for current transaction. RTT = 32.42 ms 18:16:27.469 SERIAL « 0x01 (1 bytes) 18:16:27.470 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.473 CNTRLR [Node 007] [+] [Configuration] 10: 255 18:16:27.476 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x0a0200ff 18:16:27.471 SERIAL « 0x0c000400070670060a0200ff77 (13 bytes) 18:16:27.472 SERIAL Buffer := 0x010c000400070670060a0200ff77 (14 bytes) 18:16:27.475 SERIAL » [ACK] (0x06) 18:16:27.477 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.478 CNTRLR » [Node 007] querying parameter #11 value... 18:16:27.476 DRIVER ACK already received, resolving transaction 18:16:27.477 DRIVER resuming send queue 18:16:27.480 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 24 └─[ConfigurationCCGet] payload: 0x0b 18:16:27.481 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:27.480 SERIAL » 0x010a0013070370050b2518a1 (12 bytes) 18:16:27.484 SERIAL « [ACK] (0x06) 18:16:27.485 DRIVER ACK received from controller for current transaction 18:16:27.485 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.490 SERIAL « 0x01 (1 bytes) 18:16:27.491 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.494 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:27.493 SERIAL « 0x04011301e8 (5 bytes) 18:16:27.493 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:27.494 SERIAL » [ACK] (0x06) 18:16:27.495 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.507 SERIAL « 0x01 (1 bytes) 18:16:27.508 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.510 DRIVER « [REQ] [SendData] [confirmation] callbackId: 24 transmitStatus: OK 18:16:27.510 DRIVER ACK received from node for current transaction. RTT = 31.07 ms 18:16:27.509 SERIAL « 0x07001318000002f1 (8 bytes) 18:16:27.509 SERIAL Buffer := 0x0107001318000002f1 (9 bytes) 18:16:27.509 SERIAL » [ACK] (0x06) 18:16:27.511 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.549 SERIAL « 0x01 (1 bytes) 18:16:27.549 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.552 CNTRLR [Node 007] [+] [Configuration] 11: 0 18:16:27.555 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x0b020000 18:16:27.550 SERIAL « 0x0c000400070670060b02000089 (13 bytes) 18:16:27.551 SERIAL Buffer := 0x010c000400070670060b02000089 (14 bytes) 18:16:27.554 SERIAL » [ACK] (0x06) 18:16:27.556 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.559 SERIAL » 0x010a0013070370050c2519a7 (12 bytes) 18:16:27.557 CNTRLR » [Node 007] querying parameter #12 value... 18:16:27.555 DRIVER ACK already received, resolving transaction 18:16:27.556 DRIVER resuming send queue 18:16:27.559 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 25 └─[ConfigurationCCGet] payload: 0x0c 18:16:27.560 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:27.566 SERIAL « [ACK] (0x06) 18:16:27.567 DRIVER ACK received from controller for current transaction 18:16:27.568 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.571 SERIAL « 0x01 (1 bytes) 18:16:27.571 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.574 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:27.572 SERIAL « 0x04011301e8 (5 bytes) 18:16:27.573 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:27.574 SERIAL » [ACK] (0x06) 18:16:27.575 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.587 SERIAL « 0x01 (1 bytes) 18:16:27.588 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.589 SERIAL « 0x07001319000002f0 (8 bytes) 18:16:27.590 DRIVER « [REQ] [SendData] [confirmation] callbackId: 25 transmitStatus: OK 18:16:27.590 SERIAL Buffer := 0x0107001319000002f0 (9 bytes) 18:16:27.590 SERIAL » [ACK] (0x06) 18:16:27.591 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.591 DRIVER ACK received from node for current transaction. RTT = 32.67 ms 18:16:27.629 SERIAL « 0x01 (1 bytes) 18:16:27.629 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.632 CNTRLR [Node 007] [+] [Configuration] 12: 0 18:16:27.635 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x0c020000 18:16:27.630 SERIAL « 0x0c000400070670060c0200008e (13 bytes) 18:16:27.631 SERIAL Buffer := 0x010c000400070670060c0200008e (14 bytes) 18:16:27.634 SERIAL » [ACK] (0x06) 18:16:27.636 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.637 CNTRLR » [Node 007] querying parameter #21 value... 18:16:27.635 DRIVER ACK already received, resolving transaction 18:16:27.636 DRIVER resuming send queue 18:16:27.638 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 26 └─[ConfigurationCCGet] payload: 0x15 18:16:27.639 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:27.639 SERIAL » 0x010a00130703700515251abd (12 bytes) 18:16:27.642 SERIAL « [ACK] (0x06) 18:16:27.643 DRIVER ACK received from controller for current transaction 18:16:27.644 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.650 SERIAL « 0x01 (1 bytes) 18:16:27.651 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.655 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:27.654 SERIAL « 0x04011301e8 (5 bytes) 18:16:27.654 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:27.654 SERIAL » [ACK] (0x06) 18:16:27.656 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.665 SERIAL « 0x01 (1 bytes) 18:16:27.666 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.667 SERIAL « 0x0700131a000002f3 (8 bytes) 18:16:27.669 DRIVER « [REQ] [SendData] [confirmation] callbackId: 26 transmitStatus: OK 18:16:27.668 SERIAL Buffer := 0x010700131a000002f3 (9 bytes) 18:16:27.669 SERIAL » [ACK] (0x06) 18:16:27.670 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.670 DRIVER ACK received from node for current transaction. RTT = 31.70 ms 18:16:27.705 SERIAL « 0x01 (1 bytes) 18:16:27.706 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.709 CNTRLR [Node 007] [+] [Configuration] 21: 0 18:16:27.711 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x150100 18:16:27.707 SERIAL « 0x0b0004000705700615010090 (12 bytes) 18:16:27.707 SERIAL Buffer := 0x010b0004000705700615010090 (13 bytes) 18:16:27.710 SERIAL » [ACK] (0x06) 18:16:27.712 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.715 SERIAL » 0x010a0013070370051e251bb7 (12 bytes) 18:16:27.713 CNTRLR » [Node 007] querying parameter #30 value... 18:16:27.711 DRIVER ACK already received, resolving transaction 18:16:27.712 DRIVER resuming send queue 18:16:27.714 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 27 └─[ConfigurationCCGet] payload: 0x1e 18:16:27.715 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:27.721 SERIAL « [ACK] (0x06) 18:16:27.722 DRIVER ACK received from controller for current transaction 18:16:27.722 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.727 SERIAL « 0x01 (1 bytes) 18:16:27.728 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.731 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:27.729 SERIAL « 0x04011301e8 (5 bytes) 18:16:27.729 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:27.730 SERIAL » [ACK] (0x06) 18:16:27.732 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.742 SERIAL « 0x01 (1 bytes) 18:16:27.743 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.746 DRIVER « [REQ] [SendData] [confirmation] callbackId: 27 transmitStatus: OK 18:16:27.745 SERIAL « 0x0700131b000002f2 (8 bytes) 18:16:27.745 SERIAL Buffer := 0x010700131b000002f2 (9 bytes) 18:16:27.746 SERIAL » [ACK] (0x06) 18:16:27.748 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.747 DRIVER ACK received from node for current transaction. RTT = 33.13 ms 18:16:27.782 SERIAL « 0x01 (1 bytes) 18:16:27.783 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.784 SERIAL « 0x0b000400070570061e01009b (12 bytes) 18:16:27.786 CNTRLR [Node 007] [+] [Configuration] 30: 0 18:16:27.788 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x1e0100 18:16:27.785 SERIAL Buffer := 0x010b000400070570061e01009b (13 bytes) 18:16:27.788 SERIAL » [ACK] (0x06) 18:16:27.792 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.795 SERIAL » 0x010a00130703700528251c86 (12 bytes) 18:16:27.793 CNTRLR » [Node 007] querying parameter #40 value... 18:16:27.789 DRIVER ACK already received, resolving transaction 18:16:27.792 DRIVER resuming send queue 18:16:27.795 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 28 └─[ConfigurationCCGet] payload: 0x28 18:16:27.796 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:27.802 SERIAL « [ACK] (0x06) 18:16:27.802 DRIVER ACK received from controller for current transaction 18:16:27.803 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.809 SERIAL « 0x01 (1 bytes) 18:16:27.809 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.812 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:27.812 SERIAL « 0x04011301e8 (5 bytes) 18:16:27.812 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:27.812 SERIAL » [ACK] (0x06) 18:16:27.813 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.824 SERIAL « 0x01 (1 bytes) 18:16:27.824 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.826 SERIAL « 0x0700131c000002f5 (8 bytes) 18:16:27.827 DRIVER « [REQ] [SendData] [confirmation] callbackId: 28 transmitStatus: OK 18:16:27.826 SERIAL Buffer := 0x010700131c000002f5 (9 bytes) 18:16:27.827 SERIAL » [ACK] (0x06) 18:16:27.829 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.828 DRIVER ACK received from node for current transaction. RTT = 34.11 ms 18:16:27.863 SERIAL « 0x01 (1 bytes) 18:16:27.864 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.870 CNTRLR [Node 007] [+] [Configuration] 40: 5 18:16:27.872 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x280105 18:16:27.866 SERIAL « 0x0b00040007057006280105a8 (12 bytes) 18:16:27.867 SERIAL Buffer := 0x010b00040007057006280105a8 (13 bytes) 18:16:27.872 SERIAL » [ACK] (0x06) 18:16:27.876 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.879 SERIAL » 0x010a0013070370052a251d85 (12 bytes) 18:16:27.877 CNTRLR » [Node 007] querying parameter #42 value... 18:16:27.873 DRIVER ACK already received, resolving transaction 18:16:27.876 DRIVER resuming send queue 18:16:27.878 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 29 └─[ConfigurationCCGet] payload: 0x2a 18:16:27.880 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:27.885 SERIAL « [ACK] (0x06) 18:16:27.886 DRIVER ACK received from controller for current transaction 18:16:27.886 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.892 SERIAL « 0x01 (1 bytes) 18:16:27.893 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.896 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:27.894 SERIAL « 0x04011301e8 (5 bytes) 18:16:27.895 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:27.895 SERIAL » [ACK] (0x06) 18:16:27.897 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.908 SERIAL « 0x01 (1 bytes) 18:16:27.908 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.910 DRIVER « [REQ] [SendData] [confirmation] callbackId: 29 transmitStatus: OK 18:16:27.909 SERIAL « 0x0700131d000002f4 (8 bytes) 18:16:27.910 SERIAL Buffer := 0x010700131d000002f4 (9 bytes) 18:16:27.910 SERIAL » [ACK] (0x06) 18:16:27.912 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.911 DRIVER ACK received from node for current transaction. RTT = 32.84 ms 18:16:27.949 SERIAL « 0x01 (1 bytes) 18:16:27.950 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.952 CNTRLR [Node 007] [+] [Configuration] 42: 0 18:16:27.955 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x2a020000 18:16:27.951 SERIAL « 0x0c000400070670062a020000a8 (13 bytes) 18:16:27.951 SERIAL Buffer := 0x010c000400070670062a020000a8 (14 bytes) 18:16:27.954 SERIAL » [ACK] (0x06) 18:16:27.956 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.957 CNTRLR » [Node 007] querying parameter #60 value... 18:16:27.955 DRIVER ACK already received, resolving transaction 18:16:27.956 DRIVER resuming send queue 18:16:27.959 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 30 └─[ConfigurationCCGet] payload: 0x3c 18:16:27.960 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:27.959 SERIAL » 0x010a0013070370053c251e90 (12 bytes) 18:16:27.962 SERIAL « [ACK] (0x06) 18:16:27.963 DRIVER ACK received from controller for current transaction 18:16:27.964 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.970 SERIAL « 0x01 (1 bytes) 18:16:27.970 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.975 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:27.973 SERIAL « 0x04011301e8 (5 bytes) 18:16:27.973 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:27.974 SERIAL » [ACK] (0x06) 18:16:27.975 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:27.985 SERIAL « 0x01 (1 bytes) 18:16:27.986 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:27.987 SERIAL « 0x0700131e000002f7 (8 bytes) 18:16:27.988 DRIVER « [REQ] [SendData] [confirmation] callbackId: 30 transmitStatus: OK 18:16:27.989 DRIVER ACK received from node for current transaction. RTT = 30.87 ms 18:16:27.988 SERIAL Buffer := 0x010700131e000002f7 (9 bytes) 18:16:27.988 SERIAL » [ACK] (0x06) 18:16:27.990 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.026 SERIAL « 0x01 (1 bytes) 18:16:28.026 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.029 CNTRLR [Node 007] [+] [Configuration] 60: 1 18:16:28.031 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x3c0101 18:16:28.033 CNTRLR » [Node 007] querying parameter #61 value... 18:16:28.027 SERIAL « 0x0b000400070570063c0101b8 (12 bytes) 18:16:28.028 SERIAL Buffer := 0x010b000400070570063c0101b8 (13 bytes) 18:16:28.031 SERIAL » [ACK] (0x06) 18:16:28.033 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.036 SERIAL » 0x010a0013070370053d251f90 (12 bytes) 18:16:28.032 DRIVER ACK already received, resolving transaction 18:16:28.032 DRIVER resuming send queue 18:16:28.035 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 31 └─[ConfigurationCCGet] payload: 0x3d 18:16:28.036 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:28.040 SERIAL « [ACK] (0x06) 18:16:28.041 DRIVER ACK received from controller for current transaction 18:16:28.041 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.047 SERIAL « 0x01 (1 bytes) 18:16:28.047 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.049 SERIAL « 0x04011301e8 (5 bytes) 18:16:28.051 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:28.050 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:28.050 SERIAL » [ACK] (0x06) 18:16:28.051 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.063 SERIAL « 0x01 (1 bytes) 18:16:28.063 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.065 DRIVER « [REQ] [SendData] [confirmation] callbackId: 31 transmitStatus: OK 18:16:28.064 SERIAL « 0x0700131f000002f6 (8 bytes) 18:16:28.065 SERIAL Buffer := 0x010700131f000002f6 (9 bytes) 18:16:28.065 SERIAL » [ACK] (0x06) 18:16:28.066 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.066 DRIVER ACK received from node for current transaction. RTT = 30.87 ms 18:16:28.103 SERIAL « 0x01 (1 bytes) 18:16:28.104 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.106 CNTRLR [Node 007] [+] [Configuration] 61: 99 18:16:28.109 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x3d0163 18:16:28.104 SERIAL « 0x0b000400070570063d0163db (12 bytes) 18:16:28.105 SERIAL Buffer := 0x010b000400070570063d0163db (13 bytes) 18:16:28.108 SERIAL » [ACK] (0x06) 18:16:28.110 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.113 SERIAL » 0x010a001307037005412520d3 (12 bytes) 18:16:28.111 CNTRLR » [Node 007] querying parameter #65 value... 18:16:28.109 DRIVER ACK already received, resolving transaction 18:16:28.110 DRIVER resuming send queue 18:16:28.113 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 32 └─[ConfigurationCCGet] payload: 0x41 18:16:28.113 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:28.118 SERIAL « [ACK] (0x06) 18:16:28.119 DRIVER ACK received from controller for current transaction 18:16:28.120 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.125 SERIAL « 0x01 (1 bytes) 18:16:28.126 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.129 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:28.127 SERIAL « 0x04011301e8 (5 bytes) 18:16:28.128 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:28.128 SERIAL » [ACK] (0x06) 18:16:28.129 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.140 SERIAL « 0x01 (1 bytes) 18:16:28.141 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.143 DRIVER « [REQ] [SendData] [confirmation] callbackId: 32 transmitStatus: OK 18:16:28.142 SERIAL « 0x07001320000003c8 (8 bytes) 18:16:28.142 SERIAL Buffer := 0x0107001320000003c8 (9 bytes) 18:16:28.143 SERIAL » [ACK] (0x06) 18:16:28.145 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.144 DRIVER ACK received from node for current transaction. RTT = 31.53 ms 18:16:28.182 SERIAL « 0x01 (1 bytes) 18:16:28.183 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.185 SERIAL « 0x0c0004000706700641020064a7 (13 bytes) 18:16:28.187 CNTRLR [Node 007] [+] [Configuration] 65: 100 18:16:28.189 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x41020064 18:16:28.186 SERIAL Buffer := 0x010c0004000706700641020064a7 (14 bytes) 18:16:28.189 SERIAL » [ACK] (0x06) 18:16:28.191 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.193 SERIAL » 0x010a001307037005422521d1 (12 bytes) 18:16:28.190 DRIVER ACK already received, resolving transaction 18:16:28.190 DRIVER resuming send queue 18:16:28.193 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 33 └─[ConfigurationCCGet] payload: 0x42 18:16:28.194 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:28.191 CNTRLR » [Node 007] querying parameter #66 value... 18:16:28.197 SERIAL « [ACK] (0x06) 18:16:28.197 DRIVER ACK received from controller for current transaction 18:16:28.198 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.207 SERIAL « 0x0104011301e8 (6 bytes) 18:16:28.209 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:28.208 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:28.208 SERIAL » [ACK] (0x06) 18:16:28.209 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.220 SERIAL « 0x01 (1 bytes) 18:16:28.220 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.223 DRIVER « [REQ] [SendData] [confirmation] callbackId: 33 transmitStatus: OK 18:16:28.221 SERIAL « 0x07001321000002c8 (8 bytes) 18:16:28.222 SERIAL Buffer := 0x0107001321000002c8 (9 bytes) 18:16:28.222 SERIAL » [ACK] (0x06) 18:16:28.224 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.223 DRIVER ACK received from node for current transaction. RTT = 30.68 ms 18:16:28.263 SERIAL « 0x01 (1 bytes) 18:16:28.264 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.270 CNTRLR [Node 007] [+] [Configuration] 66: 3 18:16:28.272 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x42020003 18:16:28.265 SERIAL « 0x0c0004000706700642020003c3 (13 bytes) 18:16:28.268 SERIAL Buffer := 0x010c0004000706700642020003c3 (14 bytes) 18:16:28.271 SERIAL » [ACK] (0x06) 18:16:28.273 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.276 SERIAL » 0x010a001307037005432522d3 (12 bytes) 18:16:28.274 CNTRLR » [Node 007] querying parameter #67 value... 18:16:28.273 DRIVER ACK already received, resolving transaction 18:16:28.273 DRIVER resuming send queue 18:16:28.275 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 34 └─[ConfigurationCCGet] payload: 0x43 18:16:28.276 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:28.285 SERIAL « [ACK] (0x06) 18:16:28.285 DRIVER ACK received from controller for current transaction 18:16:28.286 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.291 SERIAL « 0x0104011301e8 (6 bytes) 18:16:28.293 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:28.292 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:28.293 SERIAL » [ACK] (0x06) 18:16:28.294 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.304 SERIAL « 0x01 (1 bytes) 18:16:28.305 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.307 DRIVER « [REQ] [SendData] [confirmation] callbackId: 34 transmitStatus: OK 18:16:28.306 SERIAL « 0x07001322000002cb (8 bytes) 18:16:28.306 SERIAL Buffer := 0x0107001322000002cb (9 bytes) 18:16:28.306 SERIAL » [ACK] (0x06) 18:16:28.308 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.308 DRIVER ACK received from node for current transaction. RTT = 32.36 ms 18:16:28.344 SERIAL « 0x01 (1 bytes) 18:16:28.345 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.348 CNTRLR [Node 007] [+] [Configuration] 67: 0 18:16:28.350 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x430100 18:16:28.346 SERIAL « 0x0b00040007057006430100c6 (12 bytes) 18:16:28.347 SERIAL Buffer := 0x010b00040007057006430100c6 (13 bytes) 18:16:28.350 SERIAL » [ACK] (0x06) 18:16:28.352 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.354 SERIAL » 0x010a001307037005442523d5 (12 bytes) 18:16:28.352 CNTRLR » [Node 007] querying parameter #68 value... 18:16:28.351 DRIVER ACK already received, resolving transaction 18:16:28.351 DRIVER resuming send queue 18:16:28.354 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 35 └─[ConfigurationCCGet] payload: 0x44 18:16:28.354 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:28.359 SERIAL « [ACK] (0x06) 18:16:28.363 DRIVER ACK received from controller for current transaction 18:16:28.364 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.365 SERIAL « 0x01 (1 bytes) 18:16:28.366 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.368 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:28.367 SERIAL « 0x04011301e8 (5 bytes) 18:16:28.367 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:28.367 SERIAL » [ACK] (0x06) 18:16:28.369 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.380 SERIAL « 0x01 (1 bytes) 18:16:28.381 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.383 DRIVER « [REQ] [SendData] [confirmation] callbackId: 35 transmitStatus: OK 18:16:28.382 SERIAL « 0x07001323000003cb (8 bytes) 18:16:28.382 SERIAL Buffer := 0x0107001323000003cb (9 bytes) 18:16:28.383 SERIAL » [ACK] (0x06) 18:16:28.385 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.384 DRIVER ACK received from node for current transaction. RTT = 30.64 ms 18:16:28.421 SERIAL « 0x01 (1 bytes) 18:16:28.422 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.428 CNTRLR [Node 007] [+] [Configuration] 68: 0 18:16:28.430 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x440100 18:16:28.423 SERIAL « 0x0b00040007057006440100c1 (12 bytes) 18:16:28.424 SERIAL Buffer := 0x010b00040007057006440100c1 (13 bytes) 18:16:28.429 SERIAL » [ACK] (0x06) 18:16:28.432 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.435 SERIAL » 0x010a0013070370056e2524f8 (12 bytes) 18:16:28.432 CNTRLR » [Node 007] querying parameter #110 value... 18:16:28.431 DRIVER ACK already received, resolving transaction 18:16:28.431 DRIVER resuming send queue 18:16:28.434 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 36 └─[ConfigurationCCGet] payload: 0x6e 18:16:28.435 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:28.440 SERIAL « [ACK] (0x06) 18:16:28.440 DRIVER ACK received from controller for current transaction 18:16:28.442 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.446 SERIAL « 0x01 (1 bytes) 18:16:28.446 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.449 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:28.447 SERIAL « 0x04011301e8 (5 bytes) 18:16:28.448 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:28.448 SERIAL » [ACK] (0x06) 18:16:28.450 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.462 SERIAL « 0x01 (1 bytes) 18:16:28.462 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.465 DRIVER « [REQ] [SendData] [confirmation] callbackId: 36 transmitStatus: OK 18:16:28.465 DRIVER ACK received from node for current transaction. RTT = 31.15 ms 18:16:28.464 SERIAL « 0x07001324000003cc (8 bytes) 18:16:28.464 SERIAL Buffer := 0x0107001324000003cc (9 bytes) 18:16:28.464 SERIAL » [ACK] (0x06) 18:16:28.466 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.504 SERIAL « 0x01 (1 bytes) 18:16:28.504 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.505 SERIAL « 0x0c000400070670066e027f188b (13 bytes) 18:16:28.507 CNTRLR [Node 007] [+] [Configuration] 110: 32536 18:16:28.510 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x6e027f18 18:16:28.511 CNTRLR » [Node 007] querying parameter #120 value... 18:16:28.506 SERIAL Buffer := 0x010c000400070670066e027f188b (14 bytes) 18:16:28.509 SERIAL » [ACK] (0x06) 18:16:28.511 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.513 SERIAL » 0x010a001307037005782525ef (12 bytes) 18:16:28.510 DRIVER ACK already received, resolving transaction 18:16:28.510 DRIVER resuming send queue 18:16:28.513 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 37 └─[ConfigurationCCGet] payload: 0x78 18:16:28.513 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:28.517 SERIAL « [ACK] (0x06) 18:16:28.518 DRIVER ACK received from controller for current transaction 18:16:28.519 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.524 SERIAL « 0x01 (1 bytes) 18:16:28.524 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.527 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:28.525 SERIAL « 0x04011301e8 (5 bytes) 18:16:28.526 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:28.526 SERIAL » [ACK] (0x06) 18:16:28.527 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.539 SERIAL « 0x01 (1 bytes) 18:16:28.540 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.542 DRIVER « [REQ] [SendData] [confirmation] callbackId: 37 transmitStatus: OK 18:16:28.541 SERIAL « 0x07001325000002cc (8 bytes) 18:16:28.541 SERIAL Buffer := 0x0107001325000002cc (9 bytes) 18:16:28.542 SERIAL » [ACK] (0x06) 18:16:28.544 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.543 DRIVER ACK received from node for current transaction. RTT = 30.56 ms 18:16:28.579 SERIAL « 0x01 (1 bytes) 18:16:28.580 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.582 CNTRLR [Node 007] [+] [Configuration] 120: 5 18:16:28.584 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x780105 18:16:28.580 SERIAL « 0x0b00040007057006780105f8 (12 bytes) 18:16:28.581 SERIAL Buffer := 0x010b00040007057006780105f8 (13 bytes) 18:16:28.584 SERIAL » [ACK] (0x06) 18:16:28.585 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.586 CNTRLR [Node 007] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 18:16:28.585 DRIVER ACK already received, resolving transaction 18:16:28.585 DRIVER resuming send queue 18:16:28.587 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:16:28.588 DRIVER Send queue: (6 messages) · [REQ] RequestNodeInfo [Node 2, asleep] · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 4, asleep] · [REQ] RequestNodeInfo [Node 5, asleep] · [REQ] RequestNodeInfo [Node 6, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] 18:16:28.608 CNTRLR [Node 007] AssociationCC: skipping interview because Multi Channel Association is supported... 18:16:28.615 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 38 └─[MultiChannelAssociationCCSupportedGroupingsGet] 18:16:28.616 SERIAL » 0x0109001307028e05252668 (11 bytes) 18:16:28.610 CNTRLR [Node 007] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 18:16:28.613 CNTRLR [Node 007] MultiChannelAssociationCC: doing a complete interview... 18:16:28.613 CNTRLR » [Node 007] querying number of association groups... 18:16:28.619 SERIAL « [ACK] (0x06) 18:16:28.620 DRIVER ACK received from controller for current transaction 18:16:28.620 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.626 SERIAL « 0x01 (1 bytes) 18:16:28.626 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.628 SERIAL « 0x04011301e8 (5 bytes) 18:16:28.629 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:28.629 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:28.629 SERIAL » [ACK] (0x06) 18:16:28.630 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.642 SERIAL « 0x01 (1 bytes) 18:16:28.642 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.644 SERIAL « 0x07001326000003ce (8 bytes) 18:16:28.645 DRIVER « [REQ] [SendData] [confirmation] callbackId: 38 transmitStatus: OK 18:16:28.644 SERIAL Buffer := 0x0107001326000003ce (9 bytes) 18:16:28.645 SERIAL » [ACK] (0x06) 18:16:28.647 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.646 DRIVER ACK received from node for current transaction. RTT = 31.04 ms 18:16:28.653 SERIAL « 0x01 (1 bytes) 18:16:28.653 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.655 SERIAL « 0x0900040007038e06057b (10 bytes) 18:16:28.657 CNTRLR [Node 007] [+] [Multi Channel Association] groupCount: [Endpoint 0] [internal] 5 18:16:28.658 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCSupportedGroupingsReport] payload: 0x05 18:16:28.655 SERIAL Buffer := 0x010900040007038e06057b (11 bytes) 18:16:28.658 SERIAL » [ACK] (0x06) 18:16:28.660 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.664 SERIAL » 0x010a001307038e020125276d (12 bytes) 18:16:28.660 CNTRLR « [Node 007] supports 5 association groups 18:16:28.661 CNTRLR » [Node 007] querying association group #1... 18:16:28.659 DRIVER ACK already received, resolving transaction 18:16:28.659 DRIVER resuming send queue 18:16:28.664 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 39 └─[MultiChannelAssociationCCGet] payload: 0x01 18:16:28.664 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:28.670 SERIAL « [ACK] (0x06) 18:16:28.670 DRIVER ACK received from controller for current transaction 18:16:28.671 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.675 SERIAL « 0x01 (1 bytes) 18:16:28.676 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.678 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:28.677 SERIAL « 0x04011301e8 (5 bytes) 18:16:28.677 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:28.677 SERIAL » [ACK] (0x06) 18:16:28.678 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.692 SERIAL « 0x01 (1 bytes) 18:16:28.692 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.693 SERIAL « 0x07001327000003cf (8 bytes) 18:16:28.695 DRIVER « [REQ] [SendData] [confirmation] callbackId: 39 transmitStatus: OK 18:16:28.694 SERIAL Buffer := 0x0107001327000003cf (9 bytes) 18:16:28.694 SERIAL » [ACK] (0x06) 18:16:28.696 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.695 DRIVER ACK received from node for current transaction. RTT = 32.34 ms 18:16:28.896 SERIAL « 0x01 (1 bytes) 18:16:28.897 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.898 SERIAL « 0x0c00040007068e03010100017a (13 bytes) 18:16:28.902 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] payload: 0x01010001 18:16:28.904 CNTRLR « [Node 007] received information for association group #1: maximum # of nodes: 1 currently assigned nodes: 1 currently assigned endpoints: 18:16:28.902 DRIVER ACK already received, resolving transaction 18:16:28.902 DRIVER resuming send queue 18:16:28.906 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 40 └─[MultiChannelAssociationCCGet] payload: 0x02 18:16:28.907 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:28.899 SERIAL Buffer := 0x010c00040007068e03010100017a (14 bytes) 18:16:28.901 SERIAL » [ACK] (0x06) 18:16:28.903 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.907 SERIAL » 0x010a001307038e0202252861 (12 bytes) 18:16:28.905 CNTRLR » [Node 007] querying association group #2... 18:16:28.911 SERIAL « [ACK] (0x06) 18:16:28.912 DRIVER ACK received from controller for current transaction 18:16:28.912 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.918 SERIAL « 0x01 (1 bytes) 18:16:28.918 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.921 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:28.920 SERIAL « 0x04011301e8 (5 bytes) 18:16:28.920 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:28.920 SERIAL » [ACK] (0x06) 18:16:28.921 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.934 SERIAL « 0x01 (1 bytes) 18:16:28.934 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:28.936 DRIVER « [REQ] [SendData] [confirmation] callbackId: 40 transmitStatus: OK 18:16:28.935 SERIAL « 0x07001328000002c1 (8 bytes) 18:16:28.935 SERIAL Buffer := 0x0107001328000002c1 (9 bytes) 18:16:28.936 SERIAL » [ACK] (0x06) 18:16:28.938 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:28.937 DRIVER ACK received from node for current transaction. RTT = 30.88 ms 18:16:29.138 SERIAL « 0x01 (1 bytes) 18:16:29.139 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:29.142 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] payload: 0x021000 18:16:29.144 CNTRLR « [Node 007] received information for association group #2: maximum # of nodes: 16 currently assigned nodes: currently assigned endpoints: 18:16:29.140 SERIAL « 0x0b00040007058e030210006d (12 bytes) 18:16:29.140 SERIAL Buffer := 0x010b00040007058e030210006d (13 bytes) 18:16:29.141 SERIAL » [ACK] (0x06) 18:16:29.143 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:29.146 SERIAL » 0x010a001307038e0203252961 (12 bytes) 18:16:29.142 DRIVER ACK already received, resolving transaction 18:16:29.143 DRIVER resuming send queue 18:16:29.146 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 41 └─[MultiChannelAssociationCCGet] payload: 0x03 18:16:29.147 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:29.144 CNTRLR » [Node 007] querying association group #3... 18:16:29.152 SERIAL « [ACK] (0x06) 18:16:29.153 DRIVER ACK received from controller for current transaction 18:16:29.153 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:29.158 SERIAL « 0x01 (1 bytes) 18:16:29.159 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:29.161 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:29.160 SERIAL « 0x04011301e8 (5 bytes) 18:16:29.160 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:29.160 SERIAL » [ACK] (0x06) 18:16:29.161 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:29.175 SERIAL « 0x01 (1 bytes) 18:16:29.176 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:29.178 DRIVER « [REQ] [SendData] [confirmation] callbackId: 41 transmitStatus: OK 18:16:29.177 SERIAL « 0x07001329000002c0 (8 bytes) 18:16:29.178 SERIAL Buffer := 0x0107001329000002c0 (9 bytes) 18:16:29.178 SERIAL » [ACK] (0x06) 18:16:29.180 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:29.179 DRIVER ACK received from node for current transaction. RTT = 33.27 ms 18:16:29.381 SERIAL « 0x01 (1 bytes) 18:16:29.382 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:29.385 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] payload: 0x031000 18:16:29.388 CNTRLR « [Node 007] received information for association group #3: maximum # of nodes: 16 currently assigned nodes: currently assigned endpoints: 18:16:29.383 SERIAL « 0x0b00040007058e030310006c (12 bytes) 18:16:29.384 SERIAL Buffer := 0x010b00040007058e030310006c (13 bytes) 18:16:29.385 SERIAL » [ACK] (0x06) 18:16:29.387 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:29.394 SERIAL » 0x010a001307038e0204252a65 (12 bytes) 18:16:29.386 DRIVER ACK already received, resolving transaction 18:16:29.387 DRIVER resuming send queue 18:16:29.393 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 42 └─[MultiChannelAssociationCCGet] payload: 0x04 18:16:29.395 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:29.388 CNTRLR » [Node 007] querying association group #4... 18:16:29.410 SERIAL « [ACK] (0x06) 18:16:29.410 DRIVER ACK received from controller for current transaction 18:16:29.411 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:29.416 SERIAL « 0x01 (1 bytes) 18:16:29.417 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:29.420 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:29.418 SERIAL « 0x04011301e8 (5 bytes) 18:16:29.419 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:29.419 SERIAL » [ACK] (0x06) 18:16:29.421 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:29.433 SERIAL « 0x01 (1 bytes) 18:16:29.434 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:29.438 DRIVER « [REQ] [SendData] [confirmation] callbackId: 42 transmitStatus: OK 18:16:29.435 SERIAL « 0x0700132a000003c2 (8 bytes) 18:16:29.436 SERIAL Buffer := 0x010700132a000003c2 (9 bytes) 18:16:29.437 SERIAL » [ACK] (0x06) 18:16:29.439 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:29.438 DRIVER ACK received from node for current transaction. RTT = 46.23 ms 18:16:29.636 SERIAL « 0x01 (1 bytes) 18:16:29.637 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:29.643 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] payload: 0x041000 18:16:29.644 CNTRLR « [Node 007] received information for association group #4: maximum # of nodes: 16 currently assigned nodes: currently assigned endpoints: 18:16:29.641 SERIAL « 0x0b00040007058e030410006b (12 bytes) 18:16:29.642 SERIAL Buffer := 0x010b00040007058e030410006b (13 bytes) 18:16:29.642 SERIAL » [ACK] (0x06) 18:16:29.644 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:29.647 SERIAL » 0x010a001307038e0205252b65 (12 bytes) 18:16:29.643 DRIVER ACK already received, resolving transaction 18:16:29.644 DRIVER resuming send queue 18:16:29.647 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 43 └─[MultiChannelAssociationCCGet] payload: 0x05 18:16:29.648 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:29.645 CNTRLR » [Node 007] querying association group #5... 18:16:29.652 SERIAL « [ACK] (0x06) 18:16:29.652 DRIVER ACK received from controller for current transaction 18:16:29.653 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:29.658 SERIAL « 0x01 (1 bytes) 18:16:29.659 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:29.660 SERIAL « 0x04011301e8 (5 bytes) 18:16:29.661 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:29.661 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:29.661 SERIAL » [ACK] (0x06) 18:16:29.662 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:29.675 SERIAL « 0x01 (1 bytes) 18:16:29.676 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:29.677 SERIAL « 0x0700132b000002c2 (8 bytes) 18:16:29.678 DRIVER « [REQ] [SendData] [confirmation] callbackId: 43 transmitStatus: OK 18:16:29.677 SERIAL Buffer := 0x010700132b000002c2 (9 bytes) 18:16:29.678 SERIAL » [ACK] (0x06) 18:16:29.680 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:29.679 DRIVER ACK received from node for current transaction. RTT = 32.45 ms 18:16:29.879 SERIAL « 0x01 (1 bytes) 18:16:29.880 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:29.882 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] payload: 0x051000 18:16:29.884 CNTRLR « [Node 007] received information for association group #5: maximum # of nodes: 16 currently assigned nodes: currently assigned endpoints: 18:16:29.881 SERIAL « 0x0b00040007058e030510006a (12 bytes) 18:16:29.881 SERIAL Buffer := 0x010b00040007058e030510006a (13 bytes) 18:16:29.882 SERIAL » [ACK] (0x06) 18:16:29.884 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:29.890 SERIAL » 0x010d001307068e0101000100252c66 (15 bytes) 18:16:29.883 DRIVER ACK already received, resolving transaction 18:16:29.883 DRIVER resuming send queue 18:16:29.889 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 44 └─[MultiChannelAssociationCCSet] payload: 0x01000100 18:16:29.890 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:29.886 CNTRLR » [Node 007] supports Z-Wave+, assigning ourselves to the Lifeline group... 18:16:29.895 SERIAL « [ACK] (0x06) 18:16:29.896 DRIVER ACK received from controller for current transaction 18:16:29.896 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:29.902 SERIAL « 0x01 (1 bytes) 18:16:29.902 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:29.904 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:29.903 SERIAL « 0x04011301e8 (5 bytes) 18:16:29.904 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:29.904 SERIAL » [ACK] (0x06) 18:16:29.905 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:29.918 SERIAL « 0x01 (1 bytes) 18:16:29.919 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:29.921 DRIVER « [REQ] [SendData] [final] callbackId: 44 transmitStatus: OK 18:16:29.923 CNTRLR [Node 007] [+] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true 18:16:29.920 SERIAL « 0x0700132c000002c5 (8 bytes) 18:16:29.920 SERIAL Buffer := 0x010700132c000002c5 (9 bytes) 18:16:29.921 SERIAL » [ACK] (0x06) 18:16:29.922 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:29.922 DRIVER ACK already received, resolving transaction 18:16:29.922 DRIVER resuming send queue 18:16:29.924 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:16:29.925 DRIVER Send queue: (6 messages) · [REQ] RequestNodeInfo [Node 2, asleep] · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 4, asleep] · [REQ] RequestNodeInfo [Node 5, asleep] · [REQ] RequestNodeInfo [Node 6, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] 18:16:29.937 CNTRLR [Node 007] AssociationGroupInfoCC: doing a complete interview... 18:16:29.941 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 45 └─[AssociationGroupInfoCCNameGet] payload: 0x01 18:16:29.942 SERIAL » 0x010a00130703590101252db3 (12 bytes) 18:16:29.939 CNTRLR » [Node 007] Association group #1: Querying name... 18:16:29.946 SERIAL « [ACK] (0x06) 18:16:29.946 DRIVER ACK received from controller for current transaction 18:16:29.946 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:29.952 SERIAL « 0x01 (1 bytes) 18:16:29.953 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:29.954 SERIAL « 0x04011301e8 (5 bytes) 18:16:29.956 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:29.955 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:29.955 SERIAL » [ACK] (0x06) 18:16:29.956 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:29.968 SERIAL « 0x01 (1 bytes) 18:16:29.968 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:29.971 DRIVER « [REQ] [SendData] [confirmation] callbackId: 45 transmitStatus: OK 18:16:29.970 SERIAL « 0x0700132d000002c4 (8 bytes) 18:16:29.970 SERIAL Buffer := 0x010700132d000002c4 (9 bytes) 18:16:29.970 SERIAL » [ACK] (0x06) 18:16:29.972 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:29.972 DRIVER ACK received from node for current transaction. RTT = 30.89 ms 18:16:29.981 SERIAL « 0x01 (1 bytes) 18:16:29.982 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:29.983 SERIAL « 0x12000400070c590201086c6966656c696e65b8 (19 bytes) 18:16:29.986 CNTRLR [Node 007] [+] [Association Group Information] name[1]: "lifeline" [internal] 18:16:29.987 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCNameReport] payload: 0x01086c6966656c696e65 18:16:29.984 SERIAL Buffer := 0x0112000400070c590201086c6966656c696e65b8 (20 bytes) 18:16:29.986 SERIAL » [ACK] (0x06) 18:16:29.989 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:29.993 SERIAL » 0x010b0013070459030001252eb4 (13 bytes) 18:16:29.989 CNTRLR « [Node 007] Association group #1 has name "lifeline" 18:16:29.989 CNTRLR » [Node 007] Association group #1: Querying info... 18:16:29.988 DRIVER ACK already received, resolving transaction 18:16:29.988 DRIVER resuming send queue 18:16:29.992 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 46 └─[AssociationGroupInfoCCInfoGet] payload: 0x0001 18:16:29.993 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:29.996 SERIAL « [ACK] (0x06) 18:16:29.997 DRIVER ACK received from controller for current transaction 18:16:29.997 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.005 SERIAL « 0x0104011301e8 (6 bytes) 18:16:30.007 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:30.005 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:30.006 SERIAL » [ACK] (0x06) 18:16:30.008 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.020 SERIAL « 0x01 (1 bytes) 18:16:30.020 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.022 DRIVER « [REQ] [SendData] [confirmation] callbackId: 46 transmitStatus: OK 18:16:30.021 SERIAL « 0x0700132e000002c7 (8 bytes) 18:16:30.021 SERIAL Buffer := 0x010700132e000002c7 (9 bytes) 18:16:30.022 SERIAL » [ACK] (0x06) 18:16:30.023 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.023 DRIVER ACK received from node for current transaction. RTT = 30.90 ms 18:16:30.032 SERIAL « 0x01 (1 bytes) 18:16:30.032 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.034 SERIAL « 0x10000400070a59040101000001000000ba (17 bytes) 18:16:30.036 CNTRLR [Node 007] [+] [Association Group Information] info[1]: [object Obj [internal] ect] 18:16:30.037 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCInfoReport] payload: 0x0101000001000000 18:16:30.034 SERIAL Buffer := 0x0110000400070a59040101000001000000ba (18 bytes) 18:16:30.037 SERIAL » [ACK] (0x06) 18:16:30.039 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.044 SERIAL » 0x010b0013070459058001252f33 (13 bytes) 18:16:30.040 CNTRLR « [Node 007] Received info for association group #1: info is dynamic: false profile: General: Lifeline 18:16:30.041 CNTRLR » [Node 007] Association group #1: Querying command list... 18:16:30.038 DRIVER ACK already received, resolving transaction 18:16:30.038 DRIVER resuming send queue 18:16:30.043 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 47 └─[AssociationGroupInfoCCCommandListGet] payload: 0x8001 18:16:30.044 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:30.049 SERIAL « [ACK] (0x06) 18:16:30.049 DRIVER ACK received from controller for current transaction 18:16:30.050 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.055 SERIAL « 0x01 (1 bytes) 18:16:30.056 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.058 SERIAL « 0x04011301e8 (5 bytes) 18:16:30.059 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:30.058 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:30.058 SERIAL » [ACK] (0x06) 18:16:30.060 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.072 SERIAL « 0x01 (1 bytes) 18:16:30.072 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.074 DRIVER « [REQ] [SendData] [confirmation] callbackId: 47 transmitStatus: OK 18:16:30.073 SERIAL « 0x0700132f000003c7 (8 bytes) 18:16:30.073 SERIAL Buffer := 0x010700132f000003c7 (9 bytes) 18:16:30.074 SERIAL » [ACK] (0x06) 18:16:30.076 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.075 DRIVER ACK received from node for current transaction. RTT = 32.32 ms 18:16:30.084 SERIAL « 0x01 (1 bytes) 18:16:30.085 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.089 CNTRLR [Node 007] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[1]: [object Map] 18:16:30.090 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCCommandListReport] payload: 0x01085a01260331053202 18:16:30.086 SERIAL « 0x12000400070c590601085a01260331053202ce (19 bytes) 18:16:30.086 SERIAL Buffer := 0x0112000400070c590601085a01260331053202ce (20 bytes) 18:16:30.089 SERIAL » [ACK] (0x06) 18:16:30.092 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.092 CNTRLR » [Node 007] Association group #2: Querying name... 18:16:30.091 DRIVER ACK already received, resolving transaction 18:16:30.091 DRIVER resuming send queue 18:16:30.094 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 48 └─[AssociationGroupInfoCCNameGet] payload: 0x02 18:16:30.095 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:30.094 SERIAL » 0x010a001307035901022530ad (12 bytes) 18:16:30.099 SERIAL « [ACK] (0x06) 18:16:30.100 DRIVER ACK received from controller for current transaction 18:16:30.100 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.106 SERIAL « 0x01 (1 bytes) 18:16:30.106 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.108 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:30.108 SERIAL « 0x04011301e8 (5 bytes) 18:16:30.108 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:30.108 SERIAL » [ACK] (0x06) 18:16:30.109 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.122 SERIAL « 0x01 (1 bytes) 18:16:30.122 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.125 DRIVER « [REQ] [SendData] [confirmation] callbackId: 48 transmitStatus: OK 18:16:30.123 SERIAL « 0x07001330000003d8 (8 bytes) 18:16:30.124 SERIAL Buffer := 0x0107001330000003d8 (9 bytes) 18:16:30.124 SERIAL » [ACK] (0x06) 18:16:30.126 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.125 DRIVER ACK received from node for current transaction. RTT = 31.42 ms 18:16:30.136 SERIAL « 0x01 (1 bytes) 18:16:30.137 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.139 CNTRLR [Node 007] [+] [Association Group Information] name[2]: "BasicSetKe [internal] y1" 18:16:30.141 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCNameReport] payload: 0x020c42617369635365744b657931 18:16:30.138 SERIAL « 0x1600040007105902020c42617369635365744b657931d1 (23 bytes) 18:16:30.138 SERIAL Buffer := 0x011600040007105902020c42617369635365744b657931d1 (24 bytes) 18:16:30.140 SERIAL » [ACK] (0x06) 18:16:30.143 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.146 SERIAL » 0x010b00130704590300022531a8 (13 bytes) 18:16:30.144 CNTRLR « [Node 007] Association group #2 has name "BasicSetKey1" 18:16:30.144 CNTRLR » [Node 007] Association group #2: Querying info... 18:16:30.142 DRIVER ACK already received, resolving transaction 18:16:30.143 DRIVER resuming send queue 18:16:30.146 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 49 └─[AssociationGroupInfoCCInfoGet] payload: 0x0002 18:16:30.147 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:30.151 SERIAL « [ACK] (0x06) 18:16:30.152 DRIVER ACK received from controller for current transaction 18:16:30.152 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.162 SERIAL « 0x0104 (2 bytes) 18:16:30.165 SERIAL [incomplete] Buffer := 0x0104 (2 bytes) 18:16:30.175 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:30.166 SERIAL « 0x011301e8 (4 bytes) 18:16:30.167 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:30.174 SERIAL » [ACK] (0x06) 18:16:30.179 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.202 SERIAL « 0x0107001331000002d8 (9 bytes) 18:16:30.204 DRIVER « [REQ] [SendData] [confirmation] callbackId: 49 transmitStatus: OK 18:16:30.202 SERIAL Buffer := 0x0107001331000002d8 (9 bytes) 18:16:30.203 SERIAL » [ACK] (0x06) 18:16:30.205 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.204 DRIVER ACK received from node for current transaction. RTT = 58.58 ms 18:16:30.208 SERIAL « 0x01 (1 bytes) 18:16:30.209 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.217 CNTRLR [Node 007] [+] [Association Group Information] info[2]: [object Obj [internal] ect] 18:16:30.219 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCInfoReport] payload: 0x0102002001000000 18:16:30.214 SERIAL « 0x10000400070a5904010200200100000099 (17 bytes) 18:16:30.215 SERIAL Buffer := 0x0110000400070a5904010200200100000099 (18 bytes) 18:16:30.218 SERIAL » [ACK] (0x06) 18:16:30.240 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.246 SERIAL » 0x010b001307045905800225322d (13 bytes) 18:16:30.241 CNTRLR « [Node 007] Received info for association group #2: info is dynamic: false profile: Control: Key 01 18:16:30.241 CNTRLR » [Node 007] Association group #2: Querying command list... 18:16:30.220 DRIVER ACK already received, resolving transaction 18:16:30.239 DRIVER resuming send queue 18:16:30.245 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 50 └─[AssociationGroupInfoCCCommandListGet] payload: 0x8002 18:16:30.246 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:30.250 SERIAL « [ACK] (0x06) 18:16:30.250 DRIVER ACK received from controller for current transaction 18:16:30.253 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.272 SERIAL « 0x0104011301e8 (6 bytes) 18:16:30.274 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:30.273 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:30.274 SERIAL » [ACK] (0x06) 18:16:30.275 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.285 SERIAL « 0x0107 (2 bytes) 18:16:30.286 SERIAL [incomplete] Buffer := 0x0107 (2 bytes) 18:16:30.288 SERIAL « 0x001332000002db (7 bytes) 18:16:30.290 DRIVER « [REQ] [SendData] [confirmation] callbackId: 50 transmitStatus: OK 18:16:30.289 SERIAL Buffer := 0x0107001332000002db (9 bytes) 18:16:30.289 SERIAL » [ACK] (0x06) 18:16:30.291 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.291 DRIVER ACK received from node for current transaction. RTT = 45.63 ms 18:16:30.310 SERIAL « 0x010c000400070659060202200188 (14 bytes) 18:16:30.319 CNTRLR [Node 007] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[2]: [object Map] 18:16:30.320 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCCommandListReport] payload: 0x02022001 18:16:30.310 SERIAL Buffer := 0x010c000400070659060202200188 (14 bytes) 18:16:30.320 SERIAL » [ACK] (0x06) 18:16:30.332 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.339 SERIAL » 0x010a001307035901032533af (12 bytes) 18:16:30.332 CNTRLR » [Node 007] Association group #3: Querying name... 18:16:30.321 DRIVER ACK already received, resolving transaction 18:16:30.328 DRIVER resuming send queue 18:16:30.338 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 51 └─[AssociationGroupInfoCCNameGet] payload: 0x03 18:16:30.340 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:30.362 SERIAL « [ACK] (0x06) 18:16:30.362 DRIVER ACK received from controller for current transaction 18:16:30.368 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.373 SERIAL « 0x01 (1 bytes) 18:16:30.374 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.386 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:30.381 SERIAL « 0x04011301e8 (5 bytes) 18:16:30.381 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:30.382 SERIAL » [ACK] (0x06) 18:16:30.386 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.398 SERIAL « 0x01 (1 bytes) 18:16:30.398 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.412 SERIAL « 0x07001333000003db (8 bytes) 18:16:30.417 DRIVER « [REQ] [SendData] [confirmation] callbackId: 51 transmitStatus: OK 18:16:30.413 SERIAL Buffer := 0x0107001333000003db (9 bytes) 18:16:30.414 SERIAL » [ACK] (0x06) 18:16:30.420 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.418 DRIVER ACK received from node for current transaction. RTT = 80.76 ms 18:16:30.425 SERIAL « 0x01 (1 bytes) 18:16:30.426 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.440 CNTRLR [Node 007] [+] [Association Group Information] name[3]: "DimmerStar [internal] tSopKey1" 18:16:30.442 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCNameReport] payload: 0x031244696d6d65725374617274536f704b657931 18:16:30.437 SERIAL « 0x1c00040007165902031244696d6d65725374617274536f704b657931ec (29 bytes) 18:16:30.439 SERIAL Buffer := 0x011c00040007165902031244696d6d65725374617274536f704b657 (30 bytes) 931ec 18:16:30.441 SERIAL » [ACK] (0x06) 18:16:30.444 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.445 CNTRLR « [Node 007] Association group #3 has name "DimmerStartSopKey1" 18:16:30.446 CNTRLR » [Node 007] Association group #3: Querying info... 18:16:30.443 DRIVER ACK already received, resolving transaction 18:16:30.444 DRIVER resuming send queue 18:16:30.450 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 52 └─[AssociationGroupInfoCCInfoGet] payload: 0x0003 18:16:30.454 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:30.453 SERIAL » 0x010b00130704590300032534ac (13 bytes) 18:16:30.460 SERIAL « [ACK] (0x06) 18:16:30.461 DRIVER ACK received from controller for current transaction 18:16:30.465 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.466 SERIAL « 0x01 (1 bytes) 18:16:30.467 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.470 SERIAL « 0x04011301e8 (5 bytes) 18:16:30.472 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:30.470 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:30.471 SERIAL » [ACK] (0x06) 18:16:30.477 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.488 SERIAL « 0x0107 (2 bytes) 18:16:30.490 SERIAL [incomplete] Buffer := 0x0107 (2 bytes) 18:16:30.496 DRIVER « [REQ] [SendData] [confirmation] callbackId: 52 transmitStatus: OK 18:16:30.493 SERIAL « 0x001334000002dd (7 bytes) 18:16:30.494 SERIAL Buffer := 0x0107001334000002dd (9 bytes) 18:16:30.495 SERIAL » [ACK] (0x06) 18:16:30.504 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.501 DRIVER ACK received from node for current transaction. RTT = 51.74 ms 18:16:30.508 SERIAL « 0x01 (1 bytes) 18:16:30.511 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.516 CNTRLR [Node 007] [+] [Association Group Information] info[3]: [object Obj [internal] ect] 18:16:30.517 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCInfoReport] payload: 0x0103002001000000 18:16:30.514 SERIAL « 0x10000400070a5904010300200100000098 (17 bytes) 18:16:30.515 SERIAL Buffer := 0x0110000400070a5904010300200100000098 (18 bytes) 18:16:30.517 SERIAL » [ACK] (0x06) 18:16:30.519 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.522 SERIAL » 0x010b001307045905800325352b (13 bytes) 18:16:30.519 CNTRLR « [Node 007] Received info for association group #3: info is dynamic: false profile: Control: Key 01 18:16:30.520 CNTRLR » [Node 007] Association group #3: Querying command list... 18:16:30.518 DRIVER ACK already received, resolving transaction 18:16:30.518 DRIVER resuming send queue 18:16:30.522 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 53 └─[AssociationGroupInfoCCCommandListGet] payload: 0x8003 18:16:30.522 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:30.526 SERIAL « [ACK] (0x06) 18:16:30.527 DRIVER ACK received from controller for current transaction 18:16:30.528 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.533 SERIAL « 0x01 (1 bytes) 18:16:30.535 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.540 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:30.538 SERIAL « 0x04011301e8 (5 bytes) 18:16:30.539 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:30.539 SERIAL » [ACK] (0x06) 18:16:30.541 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.550 SERIAL « 0x01 (1 bytes) 18:16:30.551 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.556 DRIVER « [REQ] [SendData] [confirmation] callbackId: 53 transmitStatus: OK 18:16:30.553 SERIAL « 0x07001335000002dc (8 bytes) 18:16:30.554 SERIAL Buffer := 0x0107001335000002dc (9 bytes) 18:16:30.554 SERIAL » [ACK] (0x06) 18:16:30.559 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.557 DRIVER ACK received from node for current transaction. RTT = 35.66 ms 18:16:30.562 SERIAL « 0x01 (1 bytes) 18:16:30.562 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.564 CNTRLR [Node 007] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[3]: [object Map] 18:16:30.566 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCCommandListReport] payload: 0x030426042605 18:16:30.563 SERIAL « 0x0e00040007085906030426042605a3 (15 bytes) 18:16:30.563 SERIAL Buffer := 0x010e00040007085906030426042605a3 (16 bytes) 18:16:30.565 SERIAL » [ACK] (0x06) 18:16:30.567 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.569 SERIAL » 0x010a001307035901042536ad (12 bytes) 18:16:30.568 CNTRLR » [Node 007] Association group #4: Querying name... 18:16:30.566 DRIVER ACK already received, resolving transaction 18:16:30.566 DRIVER resuming send queue 18:16:30.569 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 54 └─[AssociationGroupInfoCCNameGet] payload: 0x04 18:16:30.570 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:30.574 SERIAL « [ACK] (0x06) 18:16:30.574 DRIVER ACK received from controller for current transaction 18:16:30.575 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.584 SERIAL « 0x01 (1 bytes) 18:16:30.585 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.588 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:30.586 SERIAL « 0x04011301e8 (5 bytes) 18:16:30.587 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:30.587 SERIAL » [ACK] (0x06) 18:16:30.591 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.596 SERIAL « 0x01 (1 bytes) 18:16:30.598 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.602 DRIVER « [REQ] [SendData] [confirmation] callbackId: 54 transmitStatus: OK 18:16:30.600 SERIAL « 0x07001336000002df (8 bytes) 18:16:30.600 SERIAL Buffer := 0x0107001336000002df (9 bytes) 18:16:30.601 SERIAL » [ACK] (0x06) 18:16:30.607 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.605 DRIVER ACK received from node for current transaction. RTT = 36.30 ms 18:16:30.617 SERIAL « 0x011700040007115902040d44696d6d65725365744b657931b6 (25 bytes) 18:16:30.619 CNTRLR [Node 007] [+] [Association Group Information] name[4]: "DimmerSetK [internal] ey1" 18:16:30.620 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCNameReport] payload: 0x040d44696d6d65725365744b657931 18:16:30.618 SERIAL Buffer := 0x011700040007115902040d44696d6d65725365744b657931b6 (25 bytes) 18:16:30.619 SERIAL » [ACK] (0x06) 18:16:30.623 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.626 SERIAL » 0x010b00130704590300042537a8 (13 bytes) 18:16:30.623 CNTRLR « [Node 007] Association group #4 has name "DimmerSetKey1" 18:16:30.624 CNTRLR » [Node 007] Association group #4: Querying info... 18:16:30.621 DRIVER ACK already received, resolving transaction 18:16:30.622 DRIVER resuming send queue 18:16:30.625 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 55 └─[AssociationGroupInfoCCInfoGet] payload: 0x0004 18:16:30.626 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:30.654 SERIAL « [ACK] (0x06) 18:16:30.655 DRIVER ACK received from controller for current transaction 18:16:30.655 SERIAL « 0x060104011301e8 (7 bytes) 18:16:30.656 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:30.656 SERIAL » [ACK] (0x06) 18:16:30.657 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.657 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:30.683 SERIAL « 0x0107001337000002de (9 bytes) 18:16:30.686 DRIVER « [REQ] [SendData] [confirmation] callbackId: 55 transmitStatus: OK 18:16:30.684 SERIAL Buffer := 0x0107001337000002de (9 bytes) 18:16:30.684 SERIAL » [ACK] (0x06) 18:16:30.688 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.687 DRIVER ACK received from node for current transaction. RTT = 61.99 ms 18:16:30.696 SERIAL « 0x01 (1 bytes) 18:16:30.697 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.723 CNTRLR [Node 007] [+] [Association Group Information] info[4]: [object Obj [internal] ect] 18:16:30.725 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCInfoReport] payload: 0x0104002001000000 18:16:30.721 SERIAL « 0x10000400070a590401040020010000009f (17 bytes) 18:16:30.722 SERIAL Buffer := 0x0110000400070a590401040020010000009f (18 bytes) 18:16:30.724 SERIAL » [ACK] (0x06) 18:16:30.739 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.767 SERIAL » 0x010b0013070459058004253821 (13 bytes) 18:16:30.740 CNTRLR « [Node 007] Received info for association group #4: info is dynamic: false profile: Control: Key 01 18:16:30.740 CNTRLR » [Node 007] Association group #4: Querying command list... 18:16:30.738 DRIVER ACK already received, resolving transaction 18:16:30.739 DRIVER resuming send queue 18:16:30.766 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 56 └─[AssociationGroupInfoCCCommandListGet] payload: 0x8004 18:16:30.768 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:30.803 SERIAL « [ACK] (0x06) 18:16:30.807 DRIVER ACK received from controller for current transaction 18:16:30.814 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.820 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:30.815 SERIAL « 0x0104011301e8 (6 bytes) 18:16:30.818 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:30.819 SERIAL » [ACK] (0x06) 18:16:30.822 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.829 SERIAL « 0x01 (1 bytes) 18:16:30.830 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.841 DRIVER « [REQ] [SendData] [confirmation] callbackId: 56 transmitStatus: OK 18:16:30.838 SERIAL « 0x07001338000002d1 (8 bytes) 18:16:30.839 SERIAL Buffer := 0x0107001338000002d1 (9 bytes) 18:16:30.839 SERIAL » [ACK] (0x06) 18:16:30.842 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.842 DRIVER ACK received from node for current transaction. RTT = 75.77 ms 18:16:30.845 SERIAL « 0x01 (1 bytes) 18:16:30.846 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.849 CNTRLR [Node 007] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[4]: [object Map] 18:16:30.852 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCCommandListReport] payload: 0x04022601 18:16:30.848 SERIAL « 0x0c000400070659060402260188 (13 bytes) 18:16:30.848 SERIAL Buffer := 0x010c000400070659060402260188 (14 bytes) 18:16:30.851 SERIAL » [ACK] (0x06) 18:16:30.854 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.857 SERIAL » 0x010a001307035901052539a3 (12 bytes) 18:16:30.854 CNTRLR » [Node 007] Association group #5: Querying name... 18:16:30.853 DRIVER ACK already received, resolving transaction 18:16:30.853 DRIVER resuming send queue 18:16:30.857 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 57 └─[AssociationGroupInfoCCNameGet] payload: 0x05 18:16:30.858 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:30.865 SERIAL « [ACK] (0x06) 18:16:30.866 DRIVER ACK received from controller for current transaction 18:16:30.866 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.872 SERIAL « 0x0104011301e8 (6 bytes) 18:16:30.877 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:30.876 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:30.876 SERIAL » [ACK] (0x06) 18:16:30.879 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.886 SERIAL « 0x01 (1 bytes) 18:16:30.887 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.897 DRIVER « [REQ] [SendData] [confirmation] callbackId: 57 transmitStatus: OK 18:16:30.896 SERIAL « 0x07001339000002d0 (8 bytes) 18:16:30.896 SERIAL Buffer := 0x0107001339000002d0 (9 bytes) 18:16:30.897 SERIAL » [ACK] (0x06) 18:16:30.899 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.898 DRIVER ACK received from node for current transaction. RTT = 41.99 ms 18:16:30.903 SERIAL « 0x01 (1 bytes) 18:16:30.903 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.905 SERIAL « 0x14000400070e5902050a54656d705265706f7274b0 (21 bytes) 18:16:30.915 CNTRLR [Node 007] [+] [Association Group Information] name[5]: "TempReport [internal] " 18:16:30.916 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCNameReport] payload: 0x050a54656d705265706f7274 18:16:30.906 SERIAL Buffer := 0x0114000400070e5902050a54656d705265706f7274b0 (22 bytes) 18:16:30.915 SERIAL » [ACK] (0x06) 18:16:30.918 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.920 SERIAL » 0x010b0013070459030005253aa4 (13 bytes) 18:16:30.918 CNTRLR « [Node 007] Association group #5 has name "TempReport" 18:16:30.918 CNTRLR » [Node 007] Association group #5: Querying info... 18:16:30.917 DRIVER ACK already received, resolving transaction 18:16:30.917 DRIVER resuming send queue 18:16:30.920 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 58 └─[AssociationGroupInfoCCInfoGet] payload: 0x0005 18:16:30.920 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:30.924 SERIAL « [ACK] (0x06) 18:16:30.925 DRIVER ACK received from controller for current transaction 18:16:30.926 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.931 SERIAL « 0x01 (1 bytes) 18:16:30.932 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.935 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:30.933 SERIAL « 0x04011301e8 (5 bytes) 18:16:30.934 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:30.935 SERIAL » [ACK] (0x06) 18:16:30.937 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.947 SERIAL « 0x01 (1 bytes) 18:16:30.948 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.951 DRIVER « [REQ] [SendData] [confirmation] callbackId: 58 transmitStatus: OK 18:16:30.949 SERIAL « 0x0700133a000002d3 (8 bytes) 18:16:30.950 SERIAL Buffer := 0x010700133a000002d3 (9 bytes) 18:16:30.950 SERIAL » [ACK] (0x06) 18:16:30.952 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.952 DRIVER ACK received from node for current transaction. RTT = 32.06 ms 18:16:30.960 SERIAL « 0x01 (1 bytes) 18:16:30.960 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.963 CNTRLR [Node 007] [+] [Association Group Information] info[5]: [object Obj [internal] ect] 18:16:30.964 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCInfoReport] payload: 0x0105003101000000 18:16:30.962 SERIAL « 0x10000400070a590401050031010000008f (17 bytes) 18:16:30.962 SERIAL Buffer := 0x0110000400070a590401050031010000008f (18 bytes) 18:16:30.964 SERIAL » [ACK] (0x06) 18:16:30.968 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.969 CNTRLR « [Node 007] Received info for association group #5: info is dynamic: false profile: Sensor: Air temperature 18:16:30.969 CNTRLR » [Node 007] Association group #5: Querying command list... 18:16:30.965 DRIVER ACK already received, resolving transaction 18:16:30.967 DRIVER resuming send queue 18:16:30.971 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 59 └─[AssociationGroupInfoCCCommandListGet] payload: 0x8005 18:16:30.973 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:30.973 SERIAL » 0x010b0013070459058005253b23 (13 bytes) 18:16:30.977 SERIAL « [ACK] (0x06) 18:16:30.977 DRIVER ACK received from controller for current transaction 18:16:30.978 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:30.989 SERIAL « 0x01 (1 bytes) 18:16:30.989 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:30.993 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:30.991 SERIAL « 0x04011301e8 (5 bytes) 18:16:30.992 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:30.992 SERIAL » [ACK] (0x06) 18:16:30.994 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:31.001 SERIAL « 0x01 (1 bytes) 18:16:31.002 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:31.004 DRIVER « [REQ] [SendData] [confirmation] callbackId: 59 transmitStatus: OK 18:16:31.003 SERIAL « 0x0700133b000002d2 (8 bytes) 18:16:31.003 SERIAL Buffer := 0x010700133b000002d2 (9 bytes) 18:16:31.003 SERIAL » [ACK] (0x06) 18:16:31.005 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:31.004 DRIVER ACK received from node for current transaction. RTT = 34.22 ms 18:16:31.013 SERIAL « 0x010c (2 bytes) 18:16:31.013 SERIAL [incomplete] Buffer := 0x010c (2 bytes) 18:16:31.017 CNTRLR [Node 007] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[5]: [object Map] 18:16:31.020 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCCommandListReport] payload: 0x05023105 18:16:31.014 SERIAL « 0x00040007065906050231059a (12 bytes) 18:16:31.015 SERIAL Buffer := 0x010c00040007065906050231059a (14 bytes) 18:16:31.017 SERIAL » [ACK] (0x06) 18:16:31.023 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:31.024 CNTRLR [Node 007] [+] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true 18:16:31.022 DRIVER ACK already received, resolving transaction 18:16:31.022 DRIVER resuming send queue 18:16:31.026 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:16:31.027 DRIVER Send queue: (6 messages) · [REQ] RequestNodeInfo [Node 2, asleep] · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 4, asleep] · [REQ] RequestNodeInfo [Node 5, asleep] · [REQ] RequestNodeInfo [Node 6, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] 18:16:31.070 CNTRLR [Node 007] NotificationCC: doing a complete interview... 18:16:31.073 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 60 └─[NotificationCCSupportedGet] 18:16:31.074 SERIAL » 0x0109001307027107253c8f (11 bytes) 18:16:31.070 CNTRLR » [Node 007] querying supported notification types... 18:16:31.077 SERIAL « [ACK] (0x06) 18:16:31.078 DRIVER ACK received from controller for current transaction 18:16:31.079 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:31.085 SERIAL « 0x01 (1 bytes) 18:16:31.087 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:31.090 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:31.088 SERIAL « 0x04011301e8 (5 bytes) 18:16:31.089 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:31.089 SERIAL » [ACK] (0x06) 18:16:31.092 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:31.100 SERIAL « 0x01 (1 bytes) 18:16:31.100 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:31.105 DRIVER « [REQ] [SendData] [confirmation] callbackId: 60 transmitStatus: OK 18:16:31.102 SERIAL « 0x0700133c000002d5 (8 bytes) 18:16:31.104 SERIAL Buffer := 0x010700133c000002d5 (9 bytes) 18:16:31.104 SERIAL » [ACK] (0x06) 18:16:31.107 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:31.106 DRIVER ACK received from node for current transaction. RTT = 33.65 ms 18:16:31.113 SERIAL « 0x01 (1 bytes) 18:16:31.113 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:31.118 CNTRLR [Node 007] [+] [Notification] supportsV1Alarm: false [Endpoint 0] [internal] 18:16:31.120 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[NotificationCCSupportedReport] payload: 0x020001 18:16:31.115 SERIAL « 0x0b0004000705710802000188 (12 bytes) 18:16:31.115 SERIAL Buffer := 0x010b0004000705710802000188 (13 bytes) 18:16:31.120 SERIAL » [ACK] (0x06) 18:16:31.122 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:31.127 SERIAL » 0x010a00130703710108253d82 (12 bytes) 18:16:31.119 CNTRLR [Node 007] [+] [Notification] supportedNotificationTyp [Endpoint 0] [internal] es: 8 18:16:31.123 CNTRLR « [Node 007] received supported notification types: · Power Management 18:16:31.124 CNTRLR » [Node 007] querying supported notification events for Power Management... 18:16:31.121 DRIVER ACK already received, resolving transaction 18:16:31.121 DRIVER resuming send queue 18:16:31.127 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 61 └─[NotificationCCEventSupportedGet] payload: 0x08 18:16:31.128 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:31.133 SERIAL « [ACK] (0x06) 18:16:31.134 DRIVER ACK received from controller for current transaction 18:16:31.134 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:31.142 SERIAL « 0x0104011301e8 (6 bytes) 18:16:31.145 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:31.143 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:31.144 SERIAL » [ACK] (0x06) 18:16:31.146 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:31.155 SERIAL « 0x01 (1 bytes) 18:16:31.156 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:31.160 DRIVER « [REQ] [SendData] [confirmation] callbackId: 61 transmitStatus: OK 18:16:31.158 SERIAL « 0x0700133d000002d4 (8 bytes) 18:16:31.158 SERIAL Buffer := 0x010700133d000002d4 (9 bytes) 18:16:31.159 SERIAL » [ACK] (0x06) 18:16:31.162 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:31.161 DRIVER ACK received from node for current transaction. RTT = 34.71 ms 18:16:31.167 SERIAL « 0x01 (1 bytes) 18:16:31.168 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:31.173 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[NotificationCCEventSupportedReport] payload: 0x08020001 18:16:31.180 CNTRLR « [Node 007] received supported notification events for Power Management: 8 18:16:31.169 SERIAL « 0x0c00040007067102080200018e (13 bytes) 18:16:31.170 SERIAL Buffer := 0x010c00040007067102080200018e (14 bytes) 18:16:31.172 SERIAL » [ACK] (0x06) 18:16:31.180 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:31.178 DRIVER ACK already received, resolving transaction 18:16:31.179 DRIVER resuming send queue 18:16:31.188 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 62 └─[NotificationCCGet] payload: 0x000800 18:16:31.188 DRIVER workOffSendQueue > skipping because a transaction is pending 18:16:31.183 CNTRLR [Node 007] [Notification] Power Management[Over-load status]: met [Endpoint 0] adata updated 18:16:31.185 CNTRLR » [Node 007] querying notification status for Power Management... 18:16:31.188 SERIAL » 0x010c001307057104000800253e84 (14 bytes) 18:16:31.200 SERIAL « [ACK] (0x06) 18:16:31.202 DRIVER ACK received from controller for current transaction 18:16:31.203 SERIAL « 0x0601 (2 bytes) 18:16:31.204 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:16:31.207 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:16:31.205 SERIAL « 0x04011301e8 (5 bytes) 18:16:31.206 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:16:31.206 SERIAL » [ACK] (0x06) 18:16:31.208 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:31.220 SERIAL « 0x010700133e000002d7 (9 bytes) 18:16:31.224 DRIVER « [REQ] [SendData] [confirmation] callbackId: 62 transmitStatus: OK 18:16:31.221 SERIAL Buffer := 0x010700133e000002d7 (9 bytes) 18:16:31.223 SERIAL » [ACK] (0x06) 18:16:31.227 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:31.225 DRIVER ACK received from node for current transaction. RTT = 38.07 ms 18:16:31.233 SERIAL « 0x010f00040007097105000000ff08fe0087 (17 bytes) 18:16:31.237 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[NotificationCCReport] payload: 0x000000ff08fe00 18:16:31.242 CNTRLR [Node 007] [+] [Notification] Power Management[unknown]: 254 [Endpoint 0] 18:16:31.234 SERIAL Buffer := 0x010f00040007097105000000ff08fe0087 (17 bytes) 18:16:31.236 SERIAL » [ACK] (0x06) 18:16:31.239 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:31.238 DRIVER ACK already received, resolving transaction 18:16:31.238 DRIVER resuming send queue 18:16:31.247 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:16:31.247 DRIVER Send queue: (6 messages) · [REQ] RequestNodeInfo [Node 2, asleep] · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 4, asleep] · [REQ] RequestNodeInfo [Node 5, asleep] · [REQ] RequestNodeInfo [Node 6, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] 18:16:31.245 CNTRLR [Node 007] [+] [Notification] interviewComplete: true [Endpoint 0] [internal] 18:16:31.269 CNTRLR [Node 007] Interview stage completed: CommandClasses 18:16:31.276 DRIVER » [Node 007] [REQ] [GetRoutingInfo] [P: Controller] removeNonRepeaters: false removeBadLinks: false 18:16:31.276 SERIAL » 0x01070080070000007f (9 bytes) 18:16:31.270 CNTRLR [Node 007] Interview stage completed: OverwriteConfig 18:16:31.272 CNTRLR » [Node 007] requesting node neighbors... 18:16:31.291 SERIAL « [ACK] (0x06) 18:16:31.292 DRIVER ACK received from controller for current transaction 18:16:31.297 CNTRLR « [Node 007] node neighbors received: 1, 4, 6, 8 18:16:31.293 SERIAL « 0x0601200180a900000000000000000000000000000000000000000000000000000 (35 bytes) 000f7 18:16:31.293 SERIAL Buffer := 0x01200180a9000000000000000000000000000000000000000000000 (34 bytes) 00000000000f7 18:16:31.294 SERIAL » [ACK] (0x06) 18:16:31.297 SERIAL The receive buffer is empty, waiting for the next chunk... 18:16:31.295 DRIVER « [RES] [GetRoutingInfo] [final] node ids: 1, 4, 6, 8 18:16:31.295 DRIVER ACK already received, resolving transaction 18:16:31.296 DRIVER resuming send queue 18:16:31.310 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:16:31.310 DRIVER Send queue: (6 messages) · [REQ] RequestNodeInfo [Node 2, asleep] · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 4, asleep] · [REQ] RequestNodeInfo [Node 5, asleep] · [REQ] RequestNodeInfo [Node 6, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] 18:16:31.298 CNTRLR [Node 007] Interview stage completed: Neighbors 18:16:31.298 CNTRLR [Node 007] Interview completed 18:16:31.301 CNTRLR [Node 007] The node is ready to be used 18:16:31.308 CNTRLR [Node 007] node is ready 18:17:22.054 SERIAL « 0x01 (1 bytes) 18:17:22.056 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.060 CNTRLR [Node 002] [+] [Battery] level: 80 [Endpoint 0] 18:17:22.057 SERIAL « 0x09000400020380035020 (10 bytes) 18:17:22.058 SERIAL Buffer := 0x0109000400020380035020 (11 bytes) 18:17:22.064 SERIAL » [ACK] (0x06) 18:17:22.065 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.063 CNTRLR [Node 002] [+] [Battery] isLow: false [Endpoint 0] 18:17:22.077 SERIAL « 0x01 (1 bytes) 18:17:22.078 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.084 CNTRLR [Node 002] [Thermostat Setpoint] setpoint[1]: metadata updated [Endpoint 0] 18:17:22.079 SERIAL « 0x0c0004000206430301420708ff (13 bytes) 18:17:22.080 SERIAL Buffer := 0x010c0004000206430301420708ff (14 bytes) 18:17:22.088 SERIAL » [ACK] (0x06) 18:17:22.089 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.086 CNTRLR [Node 002] [+] [Thermostat Setpoint] setpoint[1]: 18 [Endpoint 0] 18:17:22.097 SERIAL « 0x010a00040002044608007fc6 (12 bytes) 18:17:22.101 CNTRLR [Node 002] [+] [Climate Control Schedule] overrideType: 0 [Endpoint 0] 18:17:22.098 SERIAL Buffer := 0x010a00040002044608007fc6 (12 bytes) 18:17:22.105 SERIAL » [ACK] (0x06) 18:17:22.106 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.103 CNTRLR [Node 002] [+] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] 18:17:22.125 SERIAL « 0x01 (1 bytes) 18:17:22.126 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.132 CNTRLR « [Node 002] received wakeup notification 18:17:22.137 DRIVER » [Node 002] [REQ] [RequestNodeInfo] [P: WakeUp] payload: 0x02 18:17:22.128 SERIAL « 0x080004000202840770 (9 bytes) 18:17:22.129 SERIAL Buffer := 0x01080004000202840770 (10 bytes) 18:17:22.130 SERIAL » [ACK] (0x06) 18:17:22.135 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.138 SERIAL » 0x010400600299 (6 bytes) 18:17:22.133 CNTRLR [Node 002] The node is now awake. 18:17:22.146 SERIAL « [ACK] (0x06) 18:17:22.146 DRIVER Unexpected ACK received 18:17:22.147 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.150 SERIAL « 0x01 (1 bytes) 18:17:22.150 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.157 DRIVER « [RES] [RequestNodeInfo] [confirmation] payload: 0x01 18:17:22.154 SERIAL « 0x040160019b (5 bytes) 18:17:22.155 SERIAL Buffer := 0x01040160019b (6 bytes) 18:17:22.156 SERIAL » [ACK] (0x06) 18:17:22.158 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.282 SERIAL « 0x01 (1 bytes) 18:17:22.282 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.289 DRIVER « [Node 002] [REQ] [ApplicationUpdateRequest] [final] payload: 0x840210040804804681728f75438684ef46818f 18:17:22.292 CNTRLR « [Node 002] node info received supported CCs: · Battery · Climate Control Schedule · Clock · Manufacturer Specific · Multi Command · Protection · Thermostat Setpoint · Version · Wake Up controlled CCs: · Climate Control Schedule · Clock · Multi Command 18:17:22.287 SERIAL « 0x160049840210040804804681728f75438684ef46818f17 (23 bytes) 18:17:22.287 SERIAL Buffer := 0x01160049840210040804804681728f75438684ef46818f17 (24 bytes) 18:17:22.288 SERIAL » [ACK] (0x06) 18:17:22.294 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.290 DRIVER ACK already received, resolving transaction 18:17:22.291 DRIVER resuming send queue 18:17:22.295 DRIVER The remaining 5 messages are for sleeping nodes, not sending anything! 18:17:22.296 DRIVER Send queue: (5 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 4, asleep] · [REQ] RequestNodeInfo [Node 5, asleep] · [REQ] RequestNodeInfo [Node 6, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] 18:17:22.320 CNTRLR [Node 002] Interview stage completed: NodeInfo 18:17:22.329 DRIVER » [Node 002] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 63 └─[ManufacturerSpecificCCGet] 18:17:22.330 SERIAL » 0x0109001302027204253f89 (11 bytes) 18:17:22.326 CNTRLR [Node 002] ManufacturerSpecificCC: doing a complete interview... 18:17:22.326 CNTRLR » [Node 002] querying manufacturer information... 18:17:22.392 SERIAL « 0x01 (1 bytes) 18:17:22.393 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.399 CNTRLR « [Node 002] Received updated node info 18:17:22.396 SERIAL « 0x160049840210040804804681728f75438684ef46818f17 (23 bytes) 18:17:22.397 SERIAL Buffer := 0x01160049840210040804804681728f75438684ef46818f17 (24 bytes) 18:17:22.398 SERIAL » [ACK] (0x06) 18:17:22.400 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.402 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 18:17:22.401 SERIAL « [CAN] (0x18) 18:17:22.403 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.502 DRIVER » [Node 002] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 63 └─[ManufacturerSpecificCCGet] 18:17:22.503 SERIAL » 0x0109001302027204253f89 (11 bytes) 18:17:22.508 SERIAL « [ACK] (0x06) 18:17:22.508 DRIVER ACK received from controller for current transaction 18:17:22.509 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.515 SERIAL « 0x01 (1 bytes) 18:17:22.515 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.519 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:17:22.517 SERIAL « 0x04011301e8 (5 bytes) 18:17:22.517 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:17:22.518 SERIAL » [ACK] (0x06) 18:17:22.520 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.531 SERIAL « 0x01 (1 bytes) 18:17:22.532 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.535 DRIVER « [REQ] [SendData] [confirmation] callbackId: 63 transmitStatus: OK 18:17:22.533 SERIAL « 0x0700133f000003d7 (8 bytes) 18:17:22.534 SERIAL Buffer := 0x010700133f000003d7 (9 bytes) 18:17:22.534 SERIAL » [ACK] (0x06) 18:17:22.537 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.536 DRIVER ACK received from node for current transaction. RTT = 207.59 ms 18:17:22.542 SERIAL « 0x01 (1 bytes) 18:17:22.543 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.546 CNTRLR [Node 002] [+] [Manufacturer Specific] manufacturerId: 2 [Endpoint 0] 18:17:22.555 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[ManufacturerSpecificCCReport] payload: 0x000200050004 18:17:22.544 SERIAL « 0x0e000400020872050002000500048b (15 bytes) 18:17:22.545 SERIAL Buffer := 0x010e000400020872050002000500048b (16 bytes) 18:17:22.552 SERIAL » [ACK] (0x06) 18:17:22.557 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.548 CNTRLR [Node 002] [+] [Manufacturer Specific] productType: 5 [Endpoint 0] 18:17:22.550 CNTRLR [Node 002] [+] [Manufacturer Specific] productId: 4 [Endpoint 0] 18:17:22.558 CNTRLR « [Node 002] received response for manufacturer information: manufacturer: Danfoss (0x02) product type: 0x05 product id: 0x04 18:17:22.559 CNTRLR [Node 002] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 18:17:22.556 DRIVER ACK already received, resolving transaction 18:17:22.557 DRIVER resuming send queue 18:17:22.561 DRIVER The remaining 5 messages are for sleeping nodes, not sending anything! 18:17:22.561 DRIVER Send queue: (5 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 4, asleep] · [REQ] RequestNodeInfo [Node 5, asleep] · [REQ] RequestNodeInfo [Node 6, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] 18:17:22.594 CNTRLR [Node 002] VersionCC: doing a complete interview... 18:17:22.600 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 64 └─[VersionCCGet] 18:17:22.601 SERIAL » 0x0109001302028611254017 (11 bytes) 18:17:22.596 CNTRLR » [Node 002] querying node versions... 18:17:22.606 SERIAL « [ACK] (0x06) 18:17:22.607 DRIVER ACK received from controller for current transaction 18:17:22.608 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.612 SERIAL « 0x01 (1 bytes) 18:17:22.613 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.617 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:17:22.614 SERIAL « 0x04011301e8 (5 bytes) 18:17:22.616 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:17:22.616 SERIAL » [ACK] (0x06) 18:17:22.618 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.630 SERIAL « 0x01 (1 bytes) 18:17:22.630 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.634 DRIVER « [REQ] [SendData] [confirmation] callbackId: 64 transmitStatus: OK 18:17:22.632 SERIAL « 0x07001340000002a9 (8 bytes) 18:17:22.632 SERIAL Buffer := 0x0107001340000002a9 (9 bytes) 18:17:22.633 SERIAL » [ACK] (0x06) 18:17:22.635 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.634 DRIVER ACK received from node for current transaction. RTT = 34.60 ms 18:17:22.641 SERIAL « 0x01 (1 bytes) 18:17:22.642 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.645 CNTRLR [Node 002] [+] [Version] libraryType: 6 [Endpoint 0] 18:17:22.653 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[VersionCCReport] payload: 0x0603430101 18:17:22.643 SERIAL « 0x0d00040002078612060343010121 (14 bytes) 18:17:22.643 SERIAL Buffer := 0x010d00040002078612060343010121 (15 bytes) 18:17:22.652 SERIAL » [ACK] (0x06) 18:17:22.655 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.659 SERIAL » 0x010a00130203861384254192 (12 bytes) 18:17:22.648 CNTRLR [Node 002] [+] [Version] protocolVersion: "3.67" [Endpoint 0] 18:17:22.651 CNTRLR [Node 002] [+] [Version] firmwareVersions: 1.1 [Endpoint 0] 18:17:22.656 CNTRLR « [Node 002] received response for node versions: library type: Routing Slave (0x06) protocol version: 3.67 firmware versions: 1.1 18:17:22.656 CNTRLR » [Node 002] querying CC versions... 18:17:22.657 CNTRLR » [Node 002] querying the CC version for Wake Up (0x84)... 18:17:22.654 DRIVER ACK already received, resolving transaction 18:17:22.654 DRIVER resuming send queue 18:17:22.659 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 65 └─[VersionCCCommandClassGet] payload: 0x84 18:17:22.660 DRIVER workOffSendQueue > skipping because a transaction is pending 18:17:22.665 SERIAL « [ACK] (0x06) 18:17:22.666 DRIVER ACK received from controller for current transaction 18:17:22.667 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.676 SERIAL « 0x0104011301e8 (6 bytes) 18:17:22.678 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:17:22.677 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:17:22.677 SERIAL » [ACK] (0x06) 18:17:22.679 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.690 SERIAL « 0x01 (1 bytes) 18:17:22.690 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.693 DRIVER « [REQ] [SendData] [confirmation] callbackId: 65 transmitStatus: OK 18:17:22.691 SERIAL « 0x07001341000002a8 (8 bytes) 18:17:22.692 SERIAL Buffer := 0x0107001341000002a8 (9 bytes) 18:17:22.692 SERIAL » [ACK] (0x06) 18:17:22.694 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.694 DRIVER ACK received from node for current transaction. RTT = 35.19 ms 18:17:22.699 SERIAL « 0x01 (1 bytes) 18:17:22.700 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.703 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8402 18:17:22.706 CNTRLR [Node 002] supports CC Wake Up (0x84) in version 2 18:17:22.701 SERIAL « 0x0a000400020486148402e3 (11 bytes) 18:17:22.701 SERIAL Buffer := 0x010a000400020486148402e3 (12 bytes) 18:17:22.702 SERIAL » [ACK] (0x06) 18:17:22.705 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.709 SERIAL » 0x010a00130203861380254295 (12 bytes) 18:17:22.704 DRIVER ACK already received, resolving transaction 18:17:22.704 DRIVER resuming send queue 18:17:22.708 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 66 └─[VersionCCCommandClassGet] payload: 0x80 18:17:22.709 DRIVER workOffSendQueue > skipping because a transaction is pending 18:17:22.706 CNTRLR » [Node 002] querying the CC version for Battery (0x80)... 18:17:22.713 SERIAL « [ACK] (0x06) 18:17:22.714 DRIVER ACK received from controller for current transaction 18:17:22.715 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.720 SERIAL « 0x01 (1 bytes) 18:17:22.721 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.724 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:17:22.722 SERIAL « 0x04011301e8 (5 bytes) 18:17:22.722 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:17:22.723 SERIAL » [ACK] (0x06) 18:17:22.724 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.736 SERIAL « 0x01 (1 bytes) 18:17:22.737 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.740 DRIVER « [REQ] [SendData] [confirmation] callbackId: 66 transmitStatus: OK 18:17:22.738 SERIAL « 0x07001342000002ab (8 bytes) 18:17:22.738 SERIAL Buffer := 0x0107001342000002ab (9 bytes) 18:17:22.739 SERIAL » [ACK] (0x06) 18:17:22.742 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.740 DRIVER ACK received from node for current transaction. RTT = 32.27 ms 18:17:22.747 SERIAL « 0x01 (1 bytes) 18:17:22.748 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.751 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8001 18:17:22.754 CNTRLR [Node 002] supports CC Battery (0x80) in version 1 18:17:22.749 SERIAL « 0x0a000400020486148001e4 (11 bytes) 18:17:22.749 SERIAL Buffer := 0x010a000400020486148001e4 (12 bytes) 18:17:22.750 SERIAL » [ACK] (0x06) 18:17:22.753 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.752 DRIVER ACK already received, resolving transaction 18:17:22.752 DRIVER resuming send queue 18:17:22.758 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 67 └─[VersionCCCommandClassGet] payload: 0x72 18:17:22.759 DRIVER workOffSendQueue > skipping because a transaction is pending 18:17:22.754 CNTRLR [Node 002] skipping query for Climate Control Schedule (0x46) because max im plemented version is 1 18:17:22.755 CNTRLR [Node 002] skipping query for Clock (0x81) because max implemented version i s 0 18:17:22.756 CNTRLR » [Node 002] querying the CC version for Manufacturer Specific (0x72)... 18:17:22.758 SERIAL » 0x010a00130203861372254366 (12 bytes) 18:17:22.764 SERIAL « [ACK] (0x06) 18:17:22.764 DRIVER ACK received from controller for current transaction 18:17:22.765 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.770 SERIAL « 0x01 (1 bytes) 18:17:22.771 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.773 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:17:22.772 SERIAL « 0x04011301e8 (5 bytes) 18:17:22.772 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:17:22.773 SERIAL » [ACK] (0x06) 18:17:22.774 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.788 SERIAL « 0x01 (1 bytes) 18:17:22.788 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.791 DRIVER « [REQ] [SendData] [confirmation] callbackId: 67 transmitStatus: OK 18:17:22.790 SERIAL « 0x07001343000002aa (8 bytes) 18:17:22.790 SERIAL Buffer := 0x0107001343000002aa (9 bytes) 18:17:22.790 SERIAL » [ACK] (0x06) 18:17:22.793 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.792 DRIVER ACK received from node for current transaction. RTT = 34.86 ms 18:17:22.798 SERIAL « 0x01 (1 bytes) 18:17:22.798 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.801 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x7201 18:17:22.803 CNTRLR [Node 002] supports CC Manufacturer Specific (0x72) in version 1 18:17:22.799 SERIAL « 0x0a00040002048614720116 (11 bytes) 18:17:22.799 SERIAL Buffer := 0x010a00040002048614720116 (12 bytes) 18:17:22.800 SERIAL » [ACK] (0x06) 18:17:22.802 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.808 SERIAL » 0x010a00130203861343254450 (12 bytes) 18:17:22.801 DRIVER ACK already received, resolving transaction 18:17:22.802 DRIVER resuming send queue 18:17:22.807 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 68 └─[VersionCCCommandClassGet] payload: 0x43 18:17:22.809 DRIVER workOffSendQueue > skipping because a transaction is pending 18:17:22.805 CNTRLR [Node 002] skipping query for Multi Command (0x8f) because max implemented v ersion is 1 18:17:22.805 CNTRLR [Node 002] skipping query for Protection (0x75) because max implemented vers ion is 0 18:17:22.806 CNTRLR » [Node 002] querying the CC version for Thermostat Setpoint (0x43)... 18:17:22.813 SERIAL « [ACK] (0x06) 18:17:22.814 DRIVER ACK received from controller for current transaction 18:17:22.814 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.820 SERIAL « 0x01 (1 bytes) 18:17:22.821 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.823 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:17:22.822 SERIAL « 0x04011301e8 (5 bytes) 18:17:22.822 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:17:22.823 SERIAL » [ACK] (0x06) 18:17:22.824 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.836 SERIAL « 0x01 (1 bytes) 18:17:22.837 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.839 DRIVER « [REQ] [SendData] [confirmation] callbackId: 68 transmitStatus: OK 18:17:22.838 SERIAL « 0x07001344000002ad (8 bytes) 18:17:22.838 SERIAL Buffer := 0x0107001344000002ad (9 bytes) 18:17:22.839 SERIAL » [ACK] (0x06) 18:17:22.841 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.840 DRIVER ACK received from node for current transaction. RTT = 33.11 ms 18:17:22.848 SERIAL « 0x01 (1 bytes) 18:17:22.848 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.851 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x4302 18:17:22.854 CNTRLR [Node 002] supports CC Thermostat Setpoint (0x43) in version 2 18:17:22.849 SERIAL « 0x0a00040002048614430224 (11 bytes) 18:17:22.850 SERIAL Buffer := 0x010a00040002048614430224 (12 bytes) 18:17:22.850 SERIAL » [ACK] (0x06) 18:17:22.853 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.858 SERIAL » 0x010a00130203861386254594 (12 bytes) 18:17:22.852 DRIVER ACK already received, resolving transaction 18:17:22.852 DRIVER resuming send queue 18:17:22.857 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 69 └─[VersionCCCommandClassGet] payload: 0x86 18:17:22.858 DRIVER workOffSendQueue > skipping because a transaction is pending 18:17:22.854 CNTRLR » [Node 002] querying the CC version for Version (0x86)... 18:17:22.862 SERIAL « [ACK] (0x06) 18:17:22.863 DRIVER ACK received from controller for current transaction 18:17:22.864 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.869 SERIAL « 0x01 (1 bytes) 18:17:22.870 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.872 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:17:22.871 SERIAL « 0x04011301e8 (5 bytes) 18:17:22.871 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:17:22.872 SERIAL » [ACK] (0x06) 18:17:22.873 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.886 SERIAL « 0x01 (1 bytes) 18:17:22.886 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.889 DRIVER « [REQ] [SendData] [confirmation] callbackId: 69 transmitStatus: OK 18:17:22.888 SERIAL « 0x07001345000002ac (8 bytes) 18:17:22.888 SERIAL Buffer := 0x0107001345000002ac (9 bytes) 18:17:22.888 SERIAL » [ACK] (0x06) 18:17:22.891 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.890 DRIVER ACK received from node for current transaction. RTT = 32.59 ms 18:17:22.897 SERIAL « 0x01 (1 bytes) 18:17:22.897 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.898 SERIAL « 0x0a000400020486148601e2 (11 bytes) 18:17:22.900 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8601 18:17:22.903 CNTRLR [Node 002] supports CC Version (0x86) in version 1 18:17:22.901 DRIVER ACK already received, resolving transaction 18:17:22.902 DRIVER resuming send queue 18:17:22.906 DRIVER The remaining 5 messages are for sleeping nodes, not sending anything! 18:17:22.906 DRIVER Send queue: (5 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 4, asleep] · [REQ] RequestNodeInfo [Node 5, asleep] · [REQ] RequestNodeInfo [Node 6, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] 18:17:22.899 SERIAL Buffer := 0x010a000400020486148601e2 (12 bytes) 18:17:22.900 SERIAL » [ACK] (0x06) 18:17:22.902 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.904 CNTRLR [Node 002] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 18:17:22.904 CNTRLR [Node 002] trying to load device config 18:17:22.911 CNTRLR [Node 002] device config loaded 18:17:22.930 CNTRLR [Node 002] WakeUpCC: doing a complete interview... 18:17:22.935 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 70 └─[WakeUpCCIntervalCapabilitiesGet] 18:17:22.936 SERIAL » 0x010900130202840925460b (11 bytes) 18:17:22.932 CNTRLR » [Node 002] retrieving wakeup capabilities from the device... 18:17:22.940 SERIAL « [ACK] (0x06) 18:17:22.940 DRIVER ACK received from controller for current transaction 18:17:22.941 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.947 SERIAL « 0x01 (1 bytes) 18:17:22.947 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.949 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:17:22.948 SERIAL « 0x04011301e8 (5 bytes) 18:17:22.949 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:17:22.949 SERIAL » [ACK] (0x06) 18:17:22.950 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.964 SERIAL « 0x01 (1 bytes) 18:17:22.964 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.967 DRIVER « [REQ] [SendData] [confirmation] callbackId: 70 transmitStatus: OK 18:17:22.965 SERIAL « 0x07001346000002af (8 bytes) 18:17:22.966 SERIAL Buffer := 0x0107001346000002af (9 bytes) 18:17:22.966 SERIAL » [ACK] (0x06) 18:17:22.969 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.968 DRIVER ACK received from node for current transaction. RTT = 33.42 ms 18:17:22.976 SERIAL « 0x01 (1 bytes) 18:17:22.977 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:22.984 CNTRLR [Node 002] [Wake Up] wakeUpInterval: metadata updated [Endpoint 0] 18:17:22.987 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[WakeUpCCIntervalCapabilitiesReport] payload: 0x00003c00070800012c00003c 18:17:22.980 SERIAL « 0x14000400020e840a00003c00070800012c00003c4f (21 bytes) 18:17:22.981 SERIAL Buffer := 0x0114000400020e840a00003c00070800012c00003c4f (22 bytes) 18:17:22.986 SERIAL » [ACK] (0x06) 18:17:22.989 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:22.993 SERIAL » 0x0109001302028405254706 (11 bytes) 18:17:22.990 CNTRLR « [Node 002] received wakeup capabilities: default wakeup interval: 300 seconds minimum wakeup interval: 60 seconds maximum wakeup interval: 1800 seconds wakeup interval steps: 60 seconds 18:17:22.990 CNTRLR » [Node 002] retrieving wakeup interval from the device... 18:17:22.988 DRIVER ACK already received, resolving transaction 18:17:22.989 DRIVER resuming send queue 18:17:22.993 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 71 └─[WakeUpCCIntervalGet] 18:17:22.994 DRIVER workOffSendQueue > skipping because a transaction is pending 18:17:22.998 SERIAL « [ACK] (0x06) 18:17:22.999 DRIVER ACK received from controller for current transaction 18:17:23.000 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:23.005 SERIAL « 0x01 (1 bytes) 18:17:23.006 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:23.009 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:17:23.008 SERIAL « 0x04011301e8 (5 bytes) 18:17:23.008 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:17:23.009 SERIAL » [ACK] (0x06) 18:17:23.010 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:23.022 SERIAL « 0x01 (1 bytes) 18:17:23.022 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:23.024 SERIAL « 0x07001347000003af (8 bytes) 18:17:23.025 DRIVER « [REQ] [SendData] [confirmation] callbackId: 71 transmitStatus: OK 18:17:23.024 SERIAL Buffer := 0x0107001347000003af (9 bytes) 18:17:23.025 SERIAL » [ACK] (0x06) 18:17:23.027 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:23.026 DRIVER ACK received from node for current transaction. RTT = 33.36 ms 18:17:23.034 SERIAL « 0x01 (1 bytes) 18:17:23.034 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:23.038 CNTRLR [Node 002] [+] [Wake Up] wakeUpInterval: 300 [Endpoint 0] 18:17:23.042 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[WakeUpCCIntervalReport] payload: 0x00012c01 18:17:23.035 SERIAL « 0x0c0004000206840600012c015d (13 bytes) 18:17:23.036 SERIAL Buffer := 0x010c0004000206840600012c015d (14 bytes) 18:17:23.041 SERIAL » [ACK] (0x06) 18:17:23.044 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:23.040 CNTRLR [Node 002] [+] [Wake Up] controllerNodeId: 1 [Endpoint 0] 18:17:23.045 CNTRLR « [Node 002] received wakeup configuration: wakeup interval: 300 seconds controller node: 1 18:17:23.048 CNTRLR [Node 002] [+] [Wake Up] interviewComplete: true [Endpoint 0] [internal] 18:17:23.050 CNTRLR [Node 002] BatteryCC: doing a complete interview... 18:17:23.050 CNTRLR » [Node 002] querying battery status... 18:17:23.043 DRIVER ACK already received, resolving transaction 18:17:23.044 DRIVER resuming send queue 18:17:23.053 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 72 └─[BatteryCCGet] 18:17:23.054 DRIVER workOffSendQueue > skipping because a transaction is pending 18:17:23.053 SERIAL » 0x010900130202800225480a (11 bytes) 18:17:23.068 SERIAL « [ACK] (0x06) 18:17:23.069 DRIVER ACK received from controller for current transaction 18:17:23.070 SERIAL « 0x0601 (2 bytes) 18:17:23.071 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:23.077 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:17:23.075 SERIAL « 0x04011301e8 (5 bytes) 18:17:23.076 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:17:23.076 SERIAL » [ACK] (0x06) 18:17:23.079 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:23.088 SERIAL « 0x0107001348000003a0 (9 bytes) 18:17:23.090 DRIVER « [REQ] [SendData] [confirmation] callbackId: 72 transmitStatus: OK 18:17:23.089 SERIAL Buffer := 0x0107001348000003a0 (9 bytes) 18:17:23.089 SERIAL » [ACK] (0x06) 18:17:23.091 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:23.091 DRIVER ACK received from node for current transaction. RTT = 38.23 ms 18:17:23.097 SERIAL « 0x01 (1 bytes) 18:17:23.098 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:23.101 CNTRLR [Node 002] [~] [Battery] level: 80 => 80 [Endpoint 0] 18:17:23.106 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[BatteryCCReport] payload: 0x50 18:17:23.099 SERIAL « 0x09000400020380035020 (10 bytes) 18:17:23.100 SERIAL Buffer := 0x0109000400020380035020 (11 bytes) 18:17:23.105 SERIAL » [ACK] (0x06) 18:17:23.108 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:23.104 CNTRLR [Node 002] [~] [Battery] isLow: false => false [Endpoint 0] 18:17:23.109 CNTRLR « [Node 002] received response for battery information: level: 80 18:17:23.110 CNTRLR [Node 002] [+] [Battery] interviewComplete: true [Endpoint 0] [internal] 18:17:23.107 DRIVER ACK already received, resolving transaction 18:17:23.107 DRIVER resuming send queue 18:17:23.111 DRIVER The remaining 5 messages are for sleeping nodes, not sending anything! 18:17:23.112 DRIVER Send queue: (5 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 4, asleep] · [REQ] RequestNodeInfo [Node 5, asleep] · [REQ] RequestNodeInfo [Node 6, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] 18:17:23.139 CNTRLR [Node 002] ThermostatSetpointCC: doing a complete interview... 18:17:23.142 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 73 └─[ThermostatSetpointCCGet] payload: 0x01 18:17:23.143 SERIAL » 0x010a001302034302012549cb (12 bytes) 18:17:23.139 CNTRLR » [Node 002] querying current value of setpoint Heating... 18:17:23.147 SERIAL « [ACK] (0x06) 18:17:23.148 DRIVER ACK received from controller for current transaction 18:17:23.149 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:23.157 SERIAL « 0x0104011301e8 (6 bytes) 18:17:23.158 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:17:23.158 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:17:23.158 SERIAL » [ACK] (0x06) 18:17:23.159 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:23.171 SERIAL « 0x01 (1 bytes) 18:17:23.172 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:23.174 DRIVER « [REQ] [SendData] [confirmation] callbackId: 73 transmitStatus: OK 18:17:23.173 SERIAL « 0x07001349000002a0 (8 bytes) 18:17:23.173 SERIAL Buffer := 0x0107001349000002a0 (9 bytes) 18:17:23.174 SERIAL » [ACK] (0x06) 18:17:23.176 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:23.175 DRIVER ACK received from node for current transaction. RTT = 33.07 ms 18:17:23.182 SERIAL « 0x01 (1 bytes) 18:17:23.183 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:23.186 CNTRLR [Node 002] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:17:23.188 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[ThermostatSetpointCCReport] payload: 0x01420708 18:17:23.184 SERIAL « 0x0c0004000206430301420708ff (13 bytes) 18:17:23.184 SERIAL Buffer := 0x010c0004000206430301420708ff (14 bytes) 18:17:23.188 SERIAL » [ACK] (0x06) 18:17:23.190 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:23.195 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:17:23.189 DRIVER ACK already received, resolving transaction 18:17:23.190 DRIVER resuming send queue 18:17:23.194 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:17:23.195 DRIVER workOffSendQueue > skipping because a transaction is pending 18:17:23.191 CNTRLR « [Node 002] received current value of setpoint Heating: 18 °C 18:17:23.192 CNTRLR » [Node 002] querying current value of setpoint Cooling... 18:17:23.199 SERIAL « [ACK] (0x06) 18:17:23.199 DRIVER ACK received from controller for current transaction 18:17:23.200 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:23.206 SERIAL « 0x01 (1 bytes) 18:17:23.207 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:23.211 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:17:23.209 SERIAL « 0x04011301e8 (5 bytes) 18:17:23.210 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:17:23.210 SERIAL » [ACK] (0x06) 18:17:23.211 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:23.222 SERIAL « 0x01 (1 bytes) 18:17:23.223 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:23.226 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:17:23.224 SERIAL « 0x0700134a000003a2 (8 bytes) 18:17:23.225 SERIAL Buffer := 0x010700134a000003a2 (9 bytes) 18:17:23.225 SERIAL » [ACK] (0x06) 18:17:23.227 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:23.226 DRIVER ACK received from node for current transaction. RTT = 32.43 ms 18:17:24.259 CNTRLR [Node 002] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:17:24.759 DRIVER » [Node 002] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:17:24.762 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:17:24.766 SERIAL « [ACK] (0x06) 18:17:24.766 DRIVER ACK received from controller for current transaction 18:17:24.768 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:24.772 SERIAL « 0x01 (1 bytes) 18:17:24.773 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:24.777 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:17:24.775 SERIAL « 0x04011301e8 (5 bytes) 18:17:24.776 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:17:24.776 SERIAL » [ACK] (0x06) 18:17:24.778 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:24.790 SERIAL « 0x01 (1 bytes) 18:17:24.791 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:24.794 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:17:24.792 SERIAL « 0x0700134a000002a3 (8 bytes) 18:17:24.792 SERIAL Buffer := 0x010700134a000002a3 (9 bytes) 18:17:24.793 SERIAL » [ACK] (0x06) 18:17:24.795 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:24.794 DRIVER ACK received from node for current transaction. RTT = 1600.49 ms 18:17:27.396 CNTRLR [Node 002] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:17:27.897 DRIVER » [Node 002] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:17:27.898 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:17:27.904 SERIAL « [ACK] (0x06) 18:17:27.904 DRIVER ACK received from controller for current transaction 18:17:27.905 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:27.910 SERIAL « 0x01 (1 bytes) 18:17:27.911 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:27.914 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:17:27.912 SERIAL « 0x04011301e8 (5 bytes) 18:17:27.913 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:17:27.913 SERIAL » [ACK] (0x06) 18:17:27.915 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:27.927 SERIAL « 0x01 (1 bytes) 18:17:27.928 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:17:27.931 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:17:27.931 DRIVER ACK received from node for current transaction. RTT = 4737.50 ms 18:17:27.929 SERIAL « 0x0700134a000002a3 (8 bytes) 18:17:27.930 SERIAL Buffer := 0x010700134a000002a3 (9 bytes) 18:17:27.930 SERIAL » [ACK] (0x06) 18:17:27.932 SERIAL The receive buffer is empty, waiting for the next chunk... 18:17:33.190 DRIVER The awake timeout for node 2 has elapsed. Assuming it is asleep. 18:17:33.191 CNTRLR [Node 002] The node is now asleep. 18:17:33.193 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:17:33.194 DRIVER Send queue: (6 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 4, asleep] · [REQ] RequestNodeInfo [Node 5, asleep] · [REQ] RequestNodeInfo [Node 6, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] 18:18:40.770 SERIAL « 0x01 (1 bytes) 18:18:40.770 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:40.774 CNTRLR [Node 005] [+] [Battery] level: 58 [Endpoint 0] 18:18:40.771 SERIAL « 0x09000400050380033a4d (10 bytes) 18:18:40.773 SERIAL Buffer := 0x0109000400050380033a4d (11 bytes) 18:18:40.777 SERIAL » [ACK] (0x06) 18:18:40.778 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:40.776 CNTRLR [Node 005] [+] [Battery] isLow: false [Endpoint 0] 18:18:40.796 SERIAL « 0x010c0004000506430301420708f8 (14 bytes) 18:18:40.798 CNTRLR [Node 005] [Thermostat Setpoint] setpoint[1]: metadata updated [Endpoint 0] 18:18:40.797 SERIAL Buffer := 0x010c0004000506430301420708f8 (14 bytes) 18:18:40.801 SERIAL » [ACK] (0x06) 18:18:40.802 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:40.800 CNTRLR [Node 005] [+] [Thermostat Setpoint] setpoint[1]: 18 [Endpoint 0] 18:18:40.814 SERIAL « 0x010a00040005044608007fc1 (12 bytes) 18:18:40.816 CNTRLR [Node 005] [+] [Climate Control Schedule] overrideType: 0 [Endpoint 0] 18:18:40.818 CNTRLR [Node 005] [+] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] 18:18:40.815 SERIAL Buffer := 0x010a00040005044608007fc1 (12 bytes) 18:18:40.819 SERIAL » [ACK] (0x06) 18:18:40.820 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:40.830 SERIAL « 0x01 (1 bytes) 18:18:40.831 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:40.837 CNTRLR « [Node 005] received wakeup notification 18:18:40.835 SERIAL « 0x080004000502840777 (9 bytes) 18:18:40.836 SERIAL Buffer := 0x01080004000502840777 (10 bytes) 18:18:40.837 SERIAL » [ACK] (0x06) 18:18:40.840 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:40.841 DRIVER » [Node 005] [REQ] [RequestNodeInfo] [P: WakeUp] payload: 0x05 18:18:40.838 CNTRLR [Node 005] The node is now awake. 18:18:40.841 SERIAL » 0x01040060059e (6 bytes) 18:18:40.847 SERIAL « [ACK] (0x06) 18:18:40.847 DRIVER ACK received from controller for current transaction 18:18:40.848 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:40.852 SERIAL « 0x01 (1 bytes) 18:18:40.853 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:40.855 DRIVER « [RES] [RequestNodeInfo] [confirmation] payload: 0x01 18:18:40.854 SERIAL « 0x040160019b (5 bytes) 18:18:40.854 SERIAL Buffer := 0x01040160019b (6 bytes) 18:18:40.854 SERIAL » [ACK] (0x06) 18:18:40.856 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:40.985 SERIAL « 0x01 (1 bytes) 18:18:40.986 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:40.988 DRIVER « [Node 005] [REQ] [ApplicationUpdateRequest] [final] payload: 0x840510040804804681728f75438684ef46818f 18:18:40.990 CNTRLR « [Node 005] node info received supported CCs: · Battery · Climate Control Schedule · Clock · Manufacturer Specific · Multi Command · Protection · Thermostat Setpoint · Version · Wake Up controlled CCs: · Climate Control Schedule · Clock · Multi Command 18:18:40.987 SERIAL « 0x160049840510040804804681728f75438684ef46818f10 (23 bytes) 18:18:40.987 SERIAL Buffer := 0x01160049840510040804804681728f75438684ef46818f10 (24 bytes) 18:18:40.987 SERIAL » [ACK] (0x06) 18:18:40.990 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:40.988 DRIVER ACK already received, resolving transaction 18:18:40.989 DRIVER resuming send queue 18:18:40.991 DRIVER The remaining 5 messages are for sleeping nodes, not sending anything! 18:18:40.992 DRIVER Send queue: (5 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 4, asleep] · [REQ] RequestNodeInfo [Node 6, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] 18:18:41.017 CNTRLR [Node 005] Interview stage completed: NodeInfo 18:18:41.021 DRIVER » [Node 005] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 75 └─[ManufacturerSpecificCCGet] 18:18:41.022 SERIAL » 0x0109001305027204254bfa (11 bytes) 18:18:41.020 CNTRLR [Node 005] ManufacturerSpecificCC: doing a complete interview... 18:18:41.020 CNTRLR » [Node 005] querying manufacturer information... 18:18:41.026 SERIAL « [ACK] (0x06) 18:18:41.027 DRIVER ACK received from controller for current transaction 18:18:41.028 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.033 SERIAL « 0x01 (1 bytes) 18:18:41.033 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.036 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:41.034 SERIAL « 0x04011301e8 (5 bytes) 18:18:41.035 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:41.035 SERIAL » [ACK] (0x06) 18:18:41.036 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.049 SERIAL « 0x01 (1 bytes) 18:18:41.050 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.052 DRIVER « [REQ] [SendData] [confirmation] callbackId: 75 transmitStatus: OK 18:18:41.051 SERIAL « 0x0700134b000002a2 (8 bytes) 18:18:41.052 SERIAL Buffer := 0x010700134b000002a2 (9 bytes) 18:18:41.052 SERIAL » [ACK] (0x06) 18:18:41.054 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.053 DRIVER ACK received from node for current transaction. RTT = 31.92 ms 18:18:41.062 SERIAL « 0x01 (1 bytes) 18:18:41.062 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.065 CNTRLR [Node 005] [+] [Manufacturer Specific] manufacturerId: 2 [Endpoint 0] 18:18:41.073 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[ManufacturerSpecificCCReport] payload: 0x000200050004 18:18:41.064 SERIAL « 0x0e000400050872050002000500048c (15 bytes) 18:18:41.064 SERIAL Buffer := 0x010e000400050872050002000500048c (16 bytes) 18:18:41.072 SERIAL » [ACK] (0x06) 18:18:41.075 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.081 SERIAL » 0x0109001305028611254c1c (11 bytes) 18:18:41.069 CNTRLR [Node 005] [+] [Manufacturer Specific] productType: 5 [Endpoint 0] 18:18:41.071 CNTRLR [Node 005] [+] [Manufacturer Specific] productId: 4 [Endpoint 0] 18:18:41.075 CNTRLR « [Node 005] received response for manufacturer information: manufacturer: Danfoss (0x02) product type: 0x05 product id: 0x04 18:18:41.076 CNTRLR [Node 005] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 18:18:41.077 CNTRLR [Node 005] VersionCC: doing a complete interview... 18:18:41.077 CNTRLR » [Node 005] querying node versions... 18:18:41.073 DRIVER ACK already received, resolving transaction 18:18:41.074 DRIVER resuming send queue 18:18:41.081 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 76 └─[VersionCCGet] 18:18:41.082 DRIVER workOffSendQueue > skipping because a transaction is pending 18:18:41.090 SERIAL « [ACK] (0x06) 18:18:41.091 DRIVER ACK received from controller for current transaction 18:18:41.091 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.104 SERIAL « 0x0104011301e8 (6 bytes) 18:18:41.106 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:41.105 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:41.105 SERIAL » [ACK] (0x06) 18:18:41.107 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.111 SERIAL « 0x01 (1 bytes) 18:18:41.111 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.114 DRIVER « [REQ] [SendData] [confirmation] callbackId: 76 transmitStatus: OK 18:18:41.112 SERIAL « 0x0700134c000002a5 (8 bytes) 18:18:41.113 SERIAL Buffer := 0x010700134c000002a5 (9 bytes) 18:18:41.114 SERIAL » [ACK] (0x06) 18:18:41.116 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.115 DRIVER ACK received from node for current transaction. RTT = 34.57 ms 18:18:41.122 SERIAL « 0x01 (1 bytes) 18:18:41.123 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.126 CNTRLR [Node 005] [+] [Version] libraryType: 6 [Endpoint 0] 18:18:41.132 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[VersionCCReport] payload: 0x0603430101 18:18:41.124 SERIAL « 0x0d00040005078612060343010126 (14 bytes) 18:18:41.125 SERIAL Buffer := 0x010d00040005078612060343010126 (15 bytes) 18:18:41.131 SERIAL » [ACK] (0x06) 18:18:41.134 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.128 CNTRLR [Node 005] [+] [Version] protocolVersion: "3.67" [Endpoint 0] 18:18:41.130 CNTRLR [Node 005] [+] [Version] firmwareVersions: 1.1 [Endpoint 0] 18:18:41.134 CNTRLR « [Node 005] received response for node versions: library type: Routing Slave (0x06) protocol version: 3.67 firmware versions: 1.1 18:18:41.135 CNTRLR » [Node 005] querying CC versions... 18:18:41.135 CNTRLR » [Node 005] querying the CC version for Wake Up (0x84)... 18:18:41.133 DRIVER ACK already received, resolving transaction 18:18:41.133 DRIVER resuming send queue 18:18:41.137 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 77 └─[VersionCCCommandClassGet] payload: 0x84 18:18:41.138 DRIVER workOffSendQueue > skipping because a transaction is pending 18:18:41.138 SERIAL » 0x010a00130503861384254d99 (12 bytes) 18:18:41.142 SERIAL « [ACK] (0x06) 18:18:41.143 DRIVER ACK received from controller for current transaction 18:18:41.143 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.148 SERIAL « 0x01 (1 bytes) 18:18:41.148 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.153 SERIAL « 0x04011301e8 (5 bytes) 18:18:41.155 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:41.154 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:41.154 SERIAL » [ACK] (0x06) 18:18:41.159 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.167 SERIAL « 0x01 (1 bytes) 18:18:41.167 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.170 DRIVER « [REQ] [SendData] [confirmation] callbackId: 77 transmitStatus: OK 18:18:41.168 SERIAL « 0x0700134d000002a4 (8 bytes) 18:18:41.169 SERIAL Buffer := 0x010700134d000002a4 (9 bytes) 18:18:41.170 SERIAL » [ACK] (0x06) 18:18:41.172 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.171 DRIVER ACK received from node for current transaction. RTT = 34.12 ms 18:18:41.176 SERIAL « 0x01 (1 bytes) 18:18:41.177 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.180 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8402 18:18:41.182 CNTRLR [Node 005] supports CC Wake Up (0x84) in version 2 18:18:41.178 SERIAL « 0x0a000400050486148402e4 (11 bytes) 18:18:41.178 SERIAL Buffer := 0x010a000400050486148402e4 (12 bytes) 18:18:41.179 SERIAL » [ACK] (0x06) 18:18:41.182 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.185 SERIAL » 0x010a00130503861380254e9e (12 bytes) 18:18:41.180 DRIVER ACK already received, resolving transaction 18:18:41.181 DRIVER resuming send queue 18:18:41.184 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 78 └─[VersionCCCommandClassGet] payload: 0x80 18:18:41.185 DRIVER workOffSendQueue > skipping because a transaction is pending 18:18:41.183 CNTRLR » [Node 005] querying the CC version for Battery (0x80)... 18:18:41.190 SERIAL « [ACK] (0x06) 18:18:41.190 DRIVER ACK received from controller for current transaction 18:18:41.191 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.196 SERIAL « 0x01 (1 bytes) 18:18:41.197 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.199 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:41.198 SERIAL « 0x04011301e8 (5 bytes) 18:18:41.198 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:41.199 SERIAL » [ACK] (0x06) 18:18:41.200 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.213 SERIAL « 0x01 (1 bytes) 18:18:41.214 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.216 SERIAL « 0x0700134e000003a6 (8 bytes) 18:18:41.217 DRIVER « [REQ] [SendData] [confirmation] callbackId: 78 transmitStatus: OK 18:18:41.216 SERIAL Buffer := 0x010700134e000003a6 (9 bytes) 18:18:41.217 SERIAL » [ACK] (0x06) 18:18:41.218 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.218 DRIVER ACK received from node for current transaction. RTT = 33.74 ms 18:18:41.224 SERIAL « 0x01 (1 bytes) 18:18:41.224 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.227 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8001 18:18:41.229 CNTRLR [Node 005] supports CC Battery (0x80) in version 1 18:18:41.225 SERIAL « 0x0a000400050486148001e3 (11 bytes) 18:18:41.226 SERIAL Buffer := 0x010a000400050486148001e3 (12 bytes) 18:18:41.226 SERIAL » [ACK] (0x06) 18:18:41.229 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.233 SERIAL » 0x010a00130503861372254f6d (12 bytes) 18:18:41.228 DRIVER ACK already received, resolving transaction 18:18:41.228 DRIVER resuming send queue 18:18:41.233 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 79 └─[VersionCCCommandClassGet] payload: 0x72 18:18:41.234 DRIVER workOffSendQueue > skipping because a transaction is pending 18:18:41.230 CNTRLR [Node 005] skipping query for Climate Control Schedule (0x46) because max im plemented version is 1 18:18:41.231 CNTRLR [Node 005] skipping query for Clock (0x81) because max implemented version i s 0 18:18:41.231 CNTRLR » [Node 005] querying the CC version for Manufacturer Specific (0x72)... 18:18:41.257 SERIAL « [ACK] (0x06) 18:18:41.258 DRIVER ACK received from controller for current transaction 18:18:41.258 SERIAL « 0x060104011301e8 (7 bytes) 18:18:41.259 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:41.259 SERIAL » [ACK] (0x06) 18:18:41.260 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.260 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:41.263 SERIAL « 0x01 (1 bytes) 18:18:41.264 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.266 DRIVER « [REQ] [SendData] [confirmation] callbackId: 79 transmitStatus: OK 18:18:41.265 SERIAL « 0x0700134f000003a7 (8 bytes) 18:18:41.265 SERIAL Buffer := 0x010700134f000003a7 (9 bytes) 18:18:41.266 SERIAL » [ACK] (0x06) 18:18:41.268 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.267 DRIVER ACK received from node for current transaction. RTT = 34.60 ms 18:18:41.273 SERIAL « 0x01 (1 bytes) 18:18:41.274 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.275 SERIAL « 0x0a00040005048614720111 (11 bytes) 18:18:41.277 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x7201 18:18:41.279 CNTRLR [Node 005] supports CC Manufacturer Specific (0x72) in version 1 18:18:41.276 SERIAL Buffer := 0x010a00040005048614720111 (12 bytes) 18:18:41.277 SERIAL » [ACK] (0x06) 18:18:41.279 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.284 SERIAL » 0x010a00130503861343255043 (12 bytes) 18:18:41.278 DRIVER ACK already received, resolving transaction 18:18:41.278 DRIVER resuming send queue 18:18:41.284 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 80 └─[VersionCCCommandClassGet] payload: 0x43 18:18:41.285 DRIVER workOffSendQueue > skipping because a transaction is pending 18:18:41.280 CNTRLR [Node 005] skipping query for Multi Command (0x8f) because max implemented v ersion is 1 18:18:41.281 CNTRLR [Node 005] skipping query for Protection (0x75) because max implemented vers ion is 0 18:18:41.281 CNTRLR » [Node 005] querying the CC version for Thermostat Setpoint (0x43)... 18:18:41.288 SERIAL « [ACK] (0x06) 18:18:41.289 DRIVER ACK received from controller for current transaction 18:18:41.289 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.295 SERIAL « 0x01 (1 bytes) 18:18:41.296 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.298 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:41.297 SERIAL « 0x04011301e8 (5 bytes) 18:18:41.297 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:41.297 SERIAL » [ACK] (0x06) 18:18:41.298 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.312 SERIAL « 0x01 (1 bytes) 18:18:41.312 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.315 DRIVER « [REQ] [SendData] [confirmation] callbackId: 80 transmitStatus: OK 18:18:41.314 SERIAL « 0x07001350000003b8 (8 bytes) 18:18:41.314 SERIAL Buffer := 0x0107001350000003b8 (9 bytes) 18:18:41.314 SERIAL » [ACK] (0x06) 18:18:41.316 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.316 DRIVER ACK received from node for current transaction. RTT = 32.41 ms 18:18:41.323 SERIAL « 0x01 (1 bytes) 18:18:41.323 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.326 SERIAL « 0x0a00040005048614430223 (11 bytes) 18:18:41.328 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x4302 18:18:41.331 CNTRLR [Node 005] supports CC Thermostat Setpoint (0x43) in version 2 18:18:41.329 DRIVER ACK already received, resolving transaction 18:18:41.330 DRIVER resuming send queue 18:18:41.333 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 81 └─[VersionCCCommandClassGet] payload: 0x86 18:18:41.334 DRIVER workOffSendQueue > skipping because a transaction is pending 18:18:41.326 SERIAL Buffer := 0x010a00040005048614430223 (12 bytes) 18:18:41.327 SERIAL » [ACK] (0x06) 18:18:41.330 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.334 SERIAL » 0x010a00130503861386255187 (12 bytes) 18:18:41.332 CNTRLR » [Node 005] querying the CC version for Version (0x86)... 18:18:41.338 SERIAL « [ACK] (0x06) 18:18:41.338 DRIVER ACK received from controller for current transaction 18:18:41.339 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.344 SERIAL « 0x01 (1 bytes) 18:18:41.345 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.347 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:41.346 SERIAL « 0x04011301e8 (5 bytes) 18:18:41.346 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:41.346 SERIAL » [ACK] (0x06) 18:18:41.347 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.361 SERIAL « 0x01 (1 bytes) 18:18:41.362 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.364 DRIVER « [REQ] [SendData] [confirmation] callbackId: 81 transmitStatus: OK 18:18:41.363 SERIAL « 0x07001351000003b9 (8 bytes) 18:18:41.363 SERIAL Buffer := 0x0107001351000003b9 (9 bytes) 18:18:41.363 SERIAL » [ACK] (0x06) 18:18:41.365 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.364 DRIVER ACK received from node for current transaction. RTT = 31.41 ms 18:18:41.376 SERIAL « 0x01 (1 bytes) 18:18:41.376 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.379 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8601 18:18:41.380 CNTRLR [Node 005] supports CC Version (0x86) in version 1 18:18:41.377 SERIAL « 0x0a000400050486148601e5 (11 bytes) 18:18:41.377 SERIAL Buffer := 0x010a000400050486148601e5 (12 bytes) 18:18:41.378 SERIAL » [ACK] (0x06) 18:18:41.380 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.379 DRIVER ACK already received, resolving transaction 18:18:41.380 DRIVER resuming send queue 18:18:41.383 DRIVER The remaining 5 messages are for sleeping nodes, not sending anything! 18:18:41.383 DRIVER Send queue: (5 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 4, asleep] · [REQ] RequestNodeInfo [Node 6, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] 18:18:41.381 CNTRLR [Node 005] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 18:18:41.382 CNTRLR [Node 005] trying to load device config 18:18:41.387 CNTRLR [Node 005] device config loaded 18:18:41.391 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 82 └─[WakeUpCCIntervalCapabilitiesGet] 18:18:41.392 SERIAL » 0x0109001305028409255218 (11 bytes) 18:18:41.388 CNTRLR [Node 005] WakeUpCC: doing a complete interview... 18:18:41.389 CNTRLR » [Node 005] retrieving wakeup capabilities from the device... 18:18:41.396 SERIAL « [ACK] (0x06) 18:18:41.396 DRIVER ACK received from controller for current transaction 18:18:41.397 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.402 SERIAL « 0x0104 (2 bytes) 18:18:41.403 SERIAL [incomplete] Buffer := 0x0104 (2 bytes) 18:18:41.405 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:41.404 SERIAL « 0x011301e8 (4 bytes) 18:18:41.404 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:41.405 SERIAL » [ACK] (0x06) 18:18:41.406 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.419 SERIAL « 0x01 (1 bytes) 18:18:41.419 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.422 DRIVER « [REQ] [SendData] [confirmation] callbackId: 82 transmitStatus: OK 18:18:41.420 SERIAL « 0x07001352000002bb (8 bytes) 18:18:41.421 SERIAL Buffer := 0x0107001352000002bb (9 bytes) 18:18:41.421 SERIAL » [ACK] (0x06) 18:18:41.423 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.422 DRIVER ACK received from node for current transaction. RTT = 31.71 ms 18:18:41.432 SERIAL « 0x0114 (2 bytes) 18:18:41.432 SERIAL [incomplete] Buffer := 0x0114 (2 bytes) 18:18:41.435 CNTRLR [Node 005] [Wake Up] wakeUpInterval: metadata updated [Endpoint 0] 18:18:41.438 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[WakeUpCCIntervalCapabilitiesReport] payload: 0x00003c00070800012c00003c 18:18:41.434 SERIAL « 0x000400050e840a00003c00070800012c00003c48 (20 bytes) 18:18:41.434 SERIAL Buffer := 0x0114000400050e840a00003c00070800012c00003c48 (22 bytes) 18:18:41.437 SERIAL » [ACK] (0x06) 18:18:41.439 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.438 DRIVER ACK already received, resolving transaction 18:18:41.439 DRIVER resuming send queue 18:18:41.444 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 83 └─[WakeUpCCIntervalGet] 18:18:41.444 DRIVER workOffSendQueue > skipping because a transaction is pending 18:18:41.440 CNTRLR « [Node 005] received wakeup capabilities: default wakeup interval: 300 seconds minimum wakeup interval: 60 seconds maximum wakeup interval: 1800 seconds wakeup interval steps: 60 seconds 18:18:41.441 CNTRLR » [Node 005] retrieving wakeup interval from the device... 18:18:41.444 SERIAL » 0x0109001305028405255315 (11 bytes) 18:18:41.449 SERIAL « [ACK] (0x06) 18:18:41.450 DRIVER ACK received from controller for current transaction 18:18:41.450 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.455 SERIAL « 0x01 (1 bytes) 18:18:41.456 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.460 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:41.458 SERIAL « 0x04011301e8 (5 bytes) 18:18:41.459 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:41.459 SERIAL » [ACK] (0x06) 18:18:41.461 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.472 SERIAL « 0x01 (1 bytes) 18:18:41.473 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.475 DRIVER « [REQ] [SendData] [confirmation] callbackId: 83 transmitStatus: OK 18:18:41.474 SERIAL « 0x07001353000003bb (8 bytes) 18:18:41.474 SERIAL Buffer := 0x0107001353000003bb (9 bytes) 18:18:41.474 SERIAL » [ACK] (0x06) 18:18:41.476 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.476 DRIVER ACK received from node for current transaction. RTT = 32.31 ms 18:18:41.483 SERIAL « 0x01 (1 bytes) 18:18:41.483 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.486 CNTRLR [Node 005] [+] [Wake Up] wakeUpInterval: 300 [Endpoint 0] 18:18:41.490 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[WakeUpCCIntervalReport] payload: 0x00012c01 18:18:41.484 SERIAL « 0x0c0004000506840600012c015a (13 bytes) 18:18:41.484 SERIAL Buffer := 0x010c0004000506840600012c015a (14 bytes) 18:18:41.489 SERIAL » [ACK] (0x06) 18:18:41.491 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.488 CNTRLR [Node 005] [+] [Wake Up] controllerNodeId: 1 [Endpoint 0] 18:18:41.492 CNTRLR « [Node 005] received wakeup configuration: wakeup interval: 300 seconds controller node: 1 18:18:41.492 CNTRLR [Node 005] [+] [Wake Up] interviewComplete: true [Endpoint 0] [internal] 18:18:41.490 DRIVER ACK already received, resolving transaction 18:18:41.491 DRIVER resuming send queue 18:18:41.494 DRIVER The remaining 5 messages are for sleeping nodes, not sending anything! 18:18:41.494 DRIVER Send queue: (5 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 4, asleep] · [REQ] RequestNodeInfo [Node 6, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] 18:18:41.522 CNTRLR [Node 005] BatteryCC: doing a complete interview... 18:18:41.525 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 84 └─[BatteryCCGet] 18:18:41.525 SERIAL » 0x0109001305028002255411 (11 bytes) 18:18:41.523 CNTRLR » [Node 005] querying battery status... 18:18:41.531 SERIAL « [ACK] (0x06) 18:18:41.531 DRIVER ACK received from controller for current transaction 18:18:41.532 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.537 SERIAL « 0x01 (1 bytes) 18:18:41.538 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.541 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:41.540 SERIAL « 0x04011301e8 (5 bytes) 18:18:41.540 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:41.541 SERIAL » [ACK] (0x06) 18:18:41.542 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.553 SERIAL « 0x01 (1 bytes) 18:18:41.554 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.556 DRIVER « [REQ] [SendData] [confirmation] callbackId: 84 transmitStatus: OK 18:18:41.555 SERIAL « 0x07001354000002bd (8 bytes) 18:18:41.555 SERIAL Buffer := 0x0107001354000002bd (9 bytes) 18:18:41.555 SERIAL » [ACK] (0x06) 18:18:41.557 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.556 DRIVER ACK received from node for current transaction. RTT = 32.13 ms 18:18:41.563 SERIAL « 0x01 (1 bytes) 18:18:41.564 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.565 SERIAL « 0x09000400050380033a4d (10 bytes) 18:18:41.567 CNTRLR [Node 005] [~] [Battery] level: 58 => 58 [Endpoint 0] 18:18:41.571 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[BatteryCCReport] payload: 0x3a 18:18:41.566 SERIAL Buffer := 0x0109000400050380033a4d (11 bytes) 18:18:41.570 SERIAL » [ACK] (0x06) 18:18:41.573 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.580 SERIAL » 0x010a001305034302012555d0 (12 bytes) 18:18:41.569 CNTRLR [Node 005] [~] [Battery] isLow: false => false [Endpoint 0] 18:18:41.574 CNTRLR « [Node 005] received response for battery information: level: 58 18:18:41.575 CNTRLR [Node 005] [+] [Battery] interviewComplete: true [Endpoint 0] [internal] 18:18:41.576 CNTRLR [Node 005] ThermostatSetpointCC: doing a complete interview... 18:18:41.577 CNTRLR » [Node 005] querying current value of setpoint Heating... 18:18:41.572 DRIVER ACK already received, resolving transaction 18:18:41.573 DRIVER resuming send queue 18:18:41.579 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 85 └─[ThermostatSetpointCCGet] payload: 0x01 18:18:41.580 DRIVER workOffSendQueue > skipping because a transaction is pending 18:18:41.585 SERIAL « [ACK] (0x06) 18:18:41.587 DRIVER ACK received from controller for current transaction 18:18:41.588 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.593 SERIAL « 0x01 (1 bytes) 18:18:41.594 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.597 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:41.595 SERIAL « 0x04011301e8 (5 bytes) 18:18:41.596 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:41.596 SERIAL » [ACK] (0x06) 18:18:41.599 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.608 SERIAL « 0x01 (1 bytes) 18:18:41.609 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.611 DRIVER « [REQ] [SendData] [confirmation] callbackId: 85 transmitStatus: OK 18:18:41.610 SERIAL « 0x07001355000002bc (8 bytes) 18:18:41.610 SERIAL Buffer := 0x0107001355000002bc (9 bytes) 18:18:41.611 SERIAL » [ACK] (0x06) 18:18:41.612 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.612 DRIVER ACK received from node for current transaction. RTT = 32.84 ms 18:18:41.619 SERIAL « 0x01 (1 bytes) 18:18:41.620 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.622 CNTRLR [Node 005] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:18:41.624 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[ThermostatSetpointCCReport] payload: 0x01420708 18:18:41.620 SERIAL « 0x0c0004000506430301420708f8 (13 bytes) 18:18:41.621 SERIAL Buffer := 0x010c0004000506430301420708f8 (14 bytes) 18:18:41.624 SERIAL » [ACK] (0x06) 18:18:41.626 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.630 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:18:41.627 CNTRLR « [Node 005] received current value of setpoint Heating: 18 °C 18:18:41.627 CNTRLR » [Node 005] querying current value of setpoint Cooling... 18:18:41.625 DRIVER ACK already received, resolving transaction 18:18:41.626 DRIVER resuming send queue 18:18:41.629 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:18:41.630 DRIVER workOffSendQueue > skipping because a transaction is pending 18:18:41.635 SERIAL « [ACK] (0x06) 18:18:41.635 DRIVER ACK received from controller for current transaction 18:18:41.636 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.641 SERIAL « 0x01 (1 bytes) 18:18:41.641 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.644 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:41.642 SERIAL « 0x04011301e8 (5 bytes) 18:18:41.643 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:41.644 SERIAL » [ACK] (0x06) 18:18:41.645 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.657 SERIAL « 0x01 (1 bytes) 18:18:41.658 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:41.661 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:18:41.659 SERIAL « 0x07001356000002bf (8 bytes) 18:18:41.660 SERIAL Buffer := 0x0107001356000002bf (9 bytes) 18:18:41.660 SERIAL » [ACK] (0x06) 18:18:41.662 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:41.661 DRIVER ACK received from node for current transaction. RTT = 32.30 ms 18:18:42.694 CNTRLR [Node 005] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:18:43.194 DRIVER » [Node 005] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:18:43.195 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:18:43.199 SERIAL « [ACK] (0x06) 18:18:43.200 DRIVER ACK received from controller for current transaction 18:18:43.200 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:43.205 SERIAL « 0x01 (1 bytes) 18:18:43.206 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:43.209 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:43.208 SERIAL « 0x04011301e8 (5 bytes) 18:18:43.208 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:43.208 SERIAL » [ACK] (0x06) 18:18:43.210 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:43.223 SERIAL « 0x01 (1 bytes) 18:18:43.224 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:43.226 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:18:43.225 SERIAL « 0x07001356000003be (8 bytes) 18:18:43.225 SERIAL Buffer := 0x0107001356000003be (9 bytes) 18:18:43.226 SERIAL » [ACK] (0x06) 18:18:43.228 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:43.227 DRIVER ACK received from node for current transaction. RTT = 1597.98 ms 18:18:45.826 CNTRLR [Node 005] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:18:46.327 DRIVER » [Node 005] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:18:46.328 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:18:46.333 SERIAL « [ACK] (0x06) 18:18:46.334 DRIVER ACK received from controller for current transaction 18:18:46.334 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:46.340 SERIAL « 0x01 (1 bytes) 18:18:46.341 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:46.344 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:46.342 SERIAL « 0x04011301e8 (5 bytes) 18:18:46.342 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:46.343 SERIAL » [ACK] (0x06) 18:18:46.348 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:46.357 SERIAL « 0x01 (1 bytes) 18:18:46.358 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:46.360 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:18:46.359 SERIAL « 0x07001356000002bf (8 bytes) 18:18:46.359 SERIAL Buffer := 0x0107001356000002bf (9 bytes) 18:18:46.360 SERIAL » [ACK] (0x06) 18:18:46.361 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:46.361 DRIVER ACK received from node for current transaction. RTT = 4731.92 ms 18:18:51.626 DRIVER The awake timeout for node 5 has elapsed. Assuming it is asleep. 18:18:51.627 CNTRLR [Node 005] The node is now asleep. 18:18:51.629 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:18:51.629 DRIVER Send queue: (6 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 4, asleep] · [REQ] RequestNodeInfo [Node 6, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] 18:18:55.723 SERIAL « 0x01 (1 bytes) 18:18:55.725 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:55.729 CNTRLR [Node 004] [+] [Battery] level: 40 [Endpoint 0] 18:18:55.728 SERIAL « 0x0900040004038003285e (10 bytes) 18:18:55.728 SERIAL Buffer := 0x010900040004038003285e (11 bytes) 18:18:55.733 SERIAL » [ACK] (0x06) 18:18:55.734 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:55.731 CNTRLR [Node 004] [+] [Battery] isLow: false [Endpoint 0] 18:18:55.745 SERIAL « 0x01 (1 bytes) 18:18:55.746 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:55.749 CNTRLR [Node 004] [Thermostat Setpoint] setpoint[1]: metadata updated [Endpoint 0] 18:18:55.747 SERIAL « 0x0c00040004064303014201f403 (13 bytes) 18:18:55.747 SERIAL Buffer := 0x010c00040004064303014201f403 (14 bytes) 18:18:55.753 SERIAL » [ACK] (0x06) 18:18:55.754 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:55.752 CNTRLR [Node 004] [+] [Thermostat Setpoint] setpoint[1]: 5 [Endpoint 0] 18:18:55.765 SERIAL « 0x01 (1 bytes) 18:18:55.765 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:55.768 CNTRLR [Node 004] [+] [Climate Control Schedule] overrideType: 0 [Endpoint 0] 18:18:55.766 SERIAL « 0x0a00040004044608007fc0 (11 bytes) 18:18:55.767 SERIAL Buffer := 0x010a00040004044608007fc0 (12 bytes) 18:18:55.773 SERIAL » [ACK] (0x06) 18:18:55.773 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:55.770 CNTRLR [Node 004] [+] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] 18:18:55.785 SERIAL « 0x01 (1 bytes) 18:18:55.785 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:55.789 CNTRLR « [Node 004] received wakeup notification 18:18:55.788 SERIAL « 0x080004000402840776 (9 bytes) 18:18:55.788 SERIAL Buffer := 0x01080004000402840776 (10 bytes) 18:18:55.789 SERIAL » [ACK] (0x06) 18:18:55.791 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:55.793 DRIVER » [Node 004] [REQ] [RequestNodeInfo] [P: WakeUp] payload: 0x04 18:18:55.790 CNTRLR [Node 004] The node is now awake. 18:18:55.793 SERIAL » 0x01040060049f (6 bytes) 18:18:55.797 SERIAL « [ACK] (0x06) 18:18:55.798 DRIVER ACK received from controller for current transaction 18:18:55.802 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:55.805 SERIAL « 0x01 (1 bytes) 18:18:55.806 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:55.808 DRIVER « [RES] [RequestNodeInfo] [confirmation] payload: 0x01 18:18:55.807 SERIAL « 0x040160019b (5 bytes) 18:18:55.807 SERIAL Buffer := 0x01040160019b (6 bytes) 18:18:55.808 SERIAL » [ACK] (0x06) 18:18:55.809 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:55.939 SERIAL « 0x01 (1 bytes) 18:18:55.939 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:55.941 DRIVER « [Node 004] [REQ] [ApplicationUpdateRequest] [final] payload: 0x840410040804804681728f75438684ef46818f 18:18:55.943 CNTRLR « [Node 004] node info received supported CCs: · Battery · Climate Control Schedule · Clock · Manufacturer Specific · Multi Command · Protection · Thermostat Setpoint · Version · Wake Up controlled CCs: · Climate Control Schedule · Clock · Multi Command 18:18:55.940 SERIAL « 0x160049840410040804804681728f75438684ef46818f11 (23 bytes) 18:18:55.940 SERIAL Buffer := 0x01160049840410040804804681728f75438684ef46818f11 (24 bytes) 18:18:55.941 SERIAL » [ACK] (0x06) 18:18:55.944 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:55.942 DRIVER ACK already received, resolving transaction 18:18:55.942 DRIVER resuming send queue 18:18:55.945 DRIVER The remaining 5 messages are for sleeping nodes, not sending anything! 18:18:55.945 DRIVER Send queue: (5 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 6, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] 18:18:55.968 CNTRLR [Node 004] Interview stage completed: NodeInfo 18:18:55.972 DRIVER » [Node 004] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 87 └─[ManufacturerSpecificCCGet] 18:18:55.973 SERIAL » 0x01090013040272042557e7 (11 bytes) 18:18:55.970 CNTRLR [Node 004] ManufacturerSpecificCC: doing a complete interview... 18:18:55.971 CNTRLR » [Node 004] querying manufacturer information... 18:18:55.977 SERIAL « [ACK] (0x06) 18:18:55.978 DRIVER ACK received from controller for current transaction 18:18:55.978 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:55.983 SERIAL « 0x01 (1 bytes) 18:18:55.984 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:55.986 SERIAL « 0x04011301e8 (5 bytes) 18:18:55.988 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:55.986 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:55.987 SERIAL » [ACK] (0x06) 18:18:55.988 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.000 SERIAL « 0x01 (1 bytes) 18:18:56.000 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.002 SERIAL « 0x07001357000002be (8 bytes) 18:18:56.004 DRIVER « [REQ] [SendData] [confirmation] callbackId: 87 transmitStatus: OK 18:18:56.003 SERIAL Buffer := 0x0107001357000002be (9 bytes) 18:18:56.003 SERIAL » [ACK] (0x06) 18:18:56.005 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.004 DRIVER ACK received from node for current transaction. RTT = 32.40 ms 18:18:56.011 SERIAL « 0x01 (1 bytes) 18:18:56.012 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.015 CNTRLR [Node 004] [+] [Manufacturer Specific] manufacturerId: 2 [Endpoint 0] 18:18:56.020 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[ManufacturerSpecificCCReport] payload: 0x000200050004 18:18:56.013 SERIAL « 0x0e000400040872050002000500048d (15 bytes) 18:18:56.013 SERIAL Buffer := 0x010e000400040872050002000500048d (16 bytes) 18:18:56.019 SERIAL » [ACK] (0x06) 18:18:56.022 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.026 SERIAL » 0x0109001304028611255809 (11 bytes) 18:18:56.016 CNTRLR [Node 004] [+] [Manufacturer Specific] productType: 5 [Endpoint 0] 18:18:56.018 CNTRLR [Node 004] [+] [Manufacturer Specific] productId: 4 [Endpoint 0] 18:18:56.022 CNTRLR « [Node 004] received response for manufacturer information: manufacturer: Danfoss (0x02) product type: 0x05 product id: 0x04 18:18:56.023 CNTRLR [Node 004] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 18:18:56.024 CNTRLR [Node 004] VersionCC: doing a complete interview... 18:18:56.024 CNTRLR » [Node 004] querying node versions... 18:18:56.021 DRIVER ACK already received, resolving transaction 18:18:56.021 DRIVER resuming send queue 18:18:56.026 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 88 └─[VersionCCGet] 18:18:56.027 DRIVER workOffSendQueue > skipping because a transaction is pending 18:18:56.032 SERIAL « [ACK] (0x06) 18:18:56.033 DRIVER ACK received from controller for current transaction 18:18:56.033 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.038 SERIAL « 0x01 (1 bytes) 18:18:56.040 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.044 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:56.042 SERIAL « 0x04011301e8 (5 bytes) 18:18:56.043 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:56.044 SERIAL » [ACK] (0x06) 18:18:56.045 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.056 SERIAL « 0x01 (1 bytes) 18:18:56.056 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.060 DRIVER « [REQ] [SendData] [confirmation] callbackId: 88 transmitStatus: OK 18:18:56.059 SERIAL « 0x07001358000002b1 (8 bytes) 18:18:56.059 SERIAL Buffer := 0x0107001358000002b1 (9 bytes) 18:18:56.060 SERIAL » [ACK] (0x06) 18:18:56.062 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.061 DRIVER ACK received from node for current transaction. RTT = 35.33 ms 18:18:56.067 SERIAL « 0x01 (1 bytes) 18:18:56.068 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.071 CNTRLR [Node 004] [+] [Version] libraryType: 6 [Endpoint 0] 18:18:56.079 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[VersionCCReport] payload: 0x0603430101 18:18:56.069 SERIAL « 0x0d00040004078612060343010127 (14 bytes) 18:18:56.070 SERIAL Buffer := 0x010d00040004078612060343010127 (15 bytes) 18:18:56.078 SERIAL » [ACK] (0x06) 18:18:56.082 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.086 SERIAL » 0x010a0013040386138425598c (12 bytes) 18:18:56.073 CNTRLR [Node 004] [+] [Version] protocolVersion: "3.67" [Endpoint 0] 18:18:56.075 CNTRLR [Node 004] [+] [Version] firmwareVersions: 1.1 [Endpoint 0] 18:18:56.082 CNTRLR « [Node 004] received response for node versions: library type: Routing Slave (0x06) protocol version: 3.67 firmware versions: 1.1 18:18:56.083 CNTRLR » [Node 004] querying CC versions... 18:18:56.083 CNTRLR » [Node 004] querying the CC version for Wake Up (0x84)... 18:18:56.080 DRIVER ACK already received, resolving transaction 18:18:56.081 DRIVER resuming send queue 18:18:56.086 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 89 └─[VersionCCCommandClassGet] payload: 0x84 18:18:56.087 DRIVER workOffSendQueue > skipping because a transaction is pending 18:18:56.091 SERIAL « [ACK] (0x06) 18:18:56.092 DRIVER ACK received from controller for current transaction 18:18:56.093 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.101 SERIAL « 0x01 (1 bytes) 18:18:56.102 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.104 SERIAL « 0x04011301e8 (5 bytes) 18:18:56.106 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:56.105 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:56.105 SERIAL » [ACK] (0x06) 18:18:56.106 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.116 SERIAL « 0x01 (1 bytes) 18:18:56.117 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.122 DRIVER « [REQ] [SendData] [confirmation] callbackId: 89 transmitStatus: OK 18:18:56.119 SERIAL « 0x07001359000002b0 (8 bytes) 18:18:56.120 SERIAL Buffer := 0x0107001359000002b0 (9 bytes) 18:18:56.121 SERIAL » [ACK] (0x06) 18:18:56.124 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.123 DRIVER ACK received from node for current transaction. RTT = 38.42 ms 18:18:56.131 SERIAL « 0x010a000400040486148402e5 (12 bytes) 18:18:56.133 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8402 18:18:56.135 CNTRLR [Node 004] supports CC Wake Up (0x84) in version 2 18:18:56.131 SERIAL Buffer := 0x010a000400040486148402e5 (12 bytes) 18:18:56.132 SERIAL » [ACK] (0x06) 18:18:56.134 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.138 SERIAL » 0x010a00130403861380255a8b (12 bytes) 18:18:56.133 DRIVER ACK already received, resolving transaction 18:18:56.134 DRIVER resuming send queue 18:18:56.137 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 90 └─[VersionCCCommandClassGet] payload: 0x80 18:18:56.138 DRIVER workOffSendQueue > skipping because a transaction is pending 18:18:56.136 CNTRLR » [Node 004] querying the CC version for Battery (0x80)... 18:18:56.142 SERIAL « [ACK] (0x06) 18:18:56.143 DRIVER ACK received from controller for current transaction 18:18:56.143 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.149 SERIAL « 0x01 (1 bytes) 18:18:56.149 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.153 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:56.151 SERIAL « 0x04011301e8 (5 bytes) 18:18:56.152 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:56.152 SERIAL » [ACK] (0x06) 18:18:56.154 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.166 SERIAL « 0x01 (1 bytes) 18:18:56.167 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.169 DRIVER « [REQ] [SendData] [confirmation] callbackId: 90 transmitStatus: OK 18:18:56.168 SERIAL « 0x0700135a000002b3 (8 bytes) 18:18:56.168 SERIAL Buffer := 0x010700135a000002b3 (9 bytes) 18:18:56.169 SERIAL » [ACK] (0x06) 18:18:56.170 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.170 DRIVER ACK received from node for current transaction. RTT = 32.78 ms 18:18:56.197 SERIAL « 0x010a000400040486148001e2 (12 bytes) 18:18:56.199 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8001 18:18:56.202 CNTRLR [Node 004] supports CC Battery (0x80) in version 1 18:18:56.198 SERIAL Buffer := 0x010a000400040486148001e2 (12 bytes) 18:18:56.198 SERIAL » [ACK] (0x06) 18:18:56.201 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.206 SERIAL » 0x010a00130403861372255b78 (12 bytes) 18:18:56.200 DRIVER ACK already received, resolving transaction 18:18:56.201 DRIVER resuming send queue 18:18:56.205 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 91 └─[VersionCCCommandClassGet] payload: 0x72 18:18:56.206 DRIVER workOffSendQueue > skipping because a transaction is pending 18:18:56.202 CNTRLR [Node 004] skipping query for Climate Control Schedule (0x46) because max im plemented version is 1 18:18:56.202 CNTRLR [Node 004] skipping query for Clock (0x81) because max implemented version i s 0 18:18:56.203 CNTRLR » [Node 004] querying the CC version for Manufacturer Specific (0x72)... 18:18:56.211 SERIAL « [ACK] (0x06) 18:18:56.211 DRIVER ACK received from controller for current transaction 18:18:56.212 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.217 SERIAL « 0x01 (1 bytes) 18:18:56.218 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.220 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:56.219 SERIAL « 0x04011301e8 (5 bytes) 18:18:56.219 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:56.219 SERIAL » [ACK] (0x06) 18:18:56.220 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.234 SERIAL « 0x01 (1 bytes) 18:18:56.234 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.236 SERIAL « 0x0700135b000002b2 (8 bytes) 18:18:56.237 DRIVER « [REQ] [SendData] [confirmation] callbackId: 91 transmitStatus: OK 18:18:56.236 SERIAL Buffer := 0x010700135b000002b2 (9 bytes) 18:18:56.236 SERIAL » [ACK] (0x06) 18:18:56.238 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.237 DRIVER ACK received from node for current transaction. RTT = 32.32 ms 18:18:56.245 SERIAL « 0x01 (1 bytes) 18:18:56.245 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.248 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x7201 18:18:56.250 CNTRLR [Node 004] supports CC Manufacturer Specific (0x72) in version 1 18:18:56.246 SERIAL « 0x0a00040004048614720110 (11 bytes) 18:18:56.247 SERIAL Buffer := 0x010a00040004048614720110 (12 bytes) 18:18:56.247 SERIAL » [ACK] (0x06) 18:18:56.250 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.255 SERIAL » 0x010a00130403861343255c4e (12 bytes) 18:18:56.249 DRIVER ACK already received, resolving transaction 18:18:56.249 DRIVER resuming send queue 18:18:56.255 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 92 └─[VersionCCCommandClassGet] payload: 0x43 18:18:56.256 DRIVER workOffSendQueue > skipping because a transaction is pending 18:18:56.252 CNTRLR [Node 004] skipping query for Multi Command (0x8f) because max implemented v ersion is 1 18:18:56.253 CNTRLR [Node 004] skipping query for Protection (0x75) because max implemented vers ion is 0 18:18:56.253 CNTRLR » [Node 004] querying the CC version for Thermostat Setpoint (0x43)... 18:18:56.260 SERIAL « [ACK] (0x06) 18:18:56.261 DRIVER ACK received from controller for current transaction 18:18:56.261 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.267 SERIAL « 0x01 (1 bytes) 18:18:56.268 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.270 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:56.269 SERIAL « 0x04011301e8 (5 bytes) 18:18:56.269 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:56.269 SERIAL » [ACK] (0x06) 18:18:56.270 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.284 SERIAL « 0x01 (1 bytes) 18:18:56.284 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.286 DRIVER « [REQ] [SendData] [confirmation] callbackId: 92 transmitStatus: OK 18:18:56.285 SERIAL « 0x0700135c000002b5 (8 bytes) 18:18:56.286 SERIAL Buffer := 0x010700135c000002b5 (9 bytes) 18:18:56.286 SERIAL » [ACK] (0x06) 18:18:56.288 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.287 DRIVER ACK received from node for current transaction. RTT = 32.70 ms 18:18:56.294 SERIAL « 0x01 (1 bytes) 18:18:56.295 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.298 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x4302 18:18:56.301 CNTRLR [Node 004] supports CC Thermostat Setpoint (0x43) in version 2 18:18:56.296 SERIAL « 0x0a00040004048614430222 (11 bytes) 18:18:56.296 SERIAL Buffer := 0x010a00040004048614430222 (12 bytes) 18:18:56.297 SERIAL » [ACK] (0x06) 18:18:56.301 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.298 DRIVER ACK already received, resolving transaction 18:18:56.299 DRIVER resuming send queue 18:18:56.304 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 93 └─[VersionCCCommandClassGet] payload: 0x86 18:18:56.305 DRIVER workOffSendQueue > skipping because a transaction is pending 18:18:56.302 CNTRLR » [Node 004] querying the CC version for Version (0x86)... 18:18:56.304 SERIAL » 0x010a00130403861386255d8a (12 bytes) 18:18:56.309 SERIAL « [ACK] (0x06) 18:18:56.309 DRIVER ACK received from controller for current transaction 18:18:56.310 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.315 SERIAL « 0x01 (1 bytes) 18:18:56.316 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.319 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:56.317 SERIAL « 0x04011301e8 (5 bytes) 18:18:56.318 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:56.318 SERIAL » [ACK] (0x06) 18:18:56.320 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.333 SERIAL « 0x01 (1 bytes) 18:18:56.333 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.335 DRIVER « [REQ] [SendData] [confirmation] callbackId: 93 transmitStatus: OK 18:18:56.334 SERIAL « 0x0700135d000003b5 (8 bytes) 18:18:56.334 SERIAL Buffer := 0x010700135d000003b5 (9 bytes) 18:18:56.334 SERIAL » [ACK] (0x06) 18:18:56.336 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.335 DRIVER ACK received from node for current transaction. RTT = 32.08 ms 18:18:56.344 SERIAL « 0x01 (1 bytes) 18:18:56.344 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.346 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8601 18:18:56.348 CNTRLR [Node 004] supports CC Version (0x86) in version 1 18:18:56.345 SERIAL « 0x0a000400040486148601e4 (11 bytes) 18:18:56.345 SERIAL Buffer := 0x010a000400040486148601e4 (12 bytes) 18:18:56.346 SERIAL » [ACK] (0x06) 18:18:56.348 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.349 CNTRLR [Node 004] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 18:18:56.350 CNTRLR [Node 004] trying to load device config 18:18:56.347 DRIVER ACK already received, resolving transaction 18:18:56.348 DRIVER resuming send queue 18:18:56.351 DRIVER The remaining 5 messages are for sleeping nodes, not sending anything! 18:18:56.351 DRIVER Send queue: (5 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 6, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] 18:18:56.354 CNTRLR [Node 004] device config loaded 18:18:56.358 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 94 └─[WakeUpCCIntervalCapabilitiesGet] 18:18:56.359 SERIAL » 0x0109001304028409255e15 (11 bytes) 18:18:56.356 CNTRLR [Node 004] WakeUpCC: doing a complete interview... 18:18:56.356 CNTRLR » [Node 004] retrieving wakeup capabilities from the device... 18:18:56.363 SERIAL « [ACK] (0x06) 18:18:56.363 DRIVER ACK received from controller for current transaction 18:18:56.364 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.369 SERIAL « 0x01 (1 bytes) 18:18:56.370 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.371 SERIAL « 0x04011301e8 (5 bytes) 18:18:56.373 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:56.372 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:56.372 SERIAL » [ACK] (0x06) 18:18:56.374 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.386 SERIAL « 0x01 (1 bytes) 18:18:56.387 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.389 DRIVER « [REQ] [SendData] [confirmation] callbackId: 94 transmitStatus: OK 18:18:56.388 SERIAL « 0x0700135e000002b7 (8 bytes) 18:18:56.388 SERIAL Buffer := 0x010700135e000002b7 (9 bytes) 18:18:56.389 SERIAL » [ACK] (0x06) 18:18:56.390 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.390 DRIVER ACK received from node for current transaction. RTT = 31.78 ms 18:18:56.399 SERIAL « 0x01 (1 bytes) 18:18:56.400 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.402 CNTRLR [Node 004] [Wake Up] wakeUpInterval: metadata updated [Endpoint 0] 18:18:56.405 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[WakeUpCCIntervalCapabilitiesReport] payload: 0x00003c00070800012c00003c 18:18:56.401 SERIAL « 0x14000400040e840a00003c00070800012c00003c49 (21 bytes) 18:18:56.401 SERIAL Buffer := 0x0114000400040e840a00003c00070800012c00003c49 (22 bytes) 18:18:56.404 SERIAL » [ACK] (0x06) 18:18:56.406 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.407 CNTRLR « [Node 004] received wakeup capabilities: default wakeup interval: 300 seconds minimum wakeup interval: 60 seconds maximum wakeup interval: 1800 seconds wakeup interval steps: 60 seconds 18:18:56.407 CNTRLR » [Node 004] retrieving wakeup interval from the device... 18:18:56.405 DRIVER ACK already received, resolving transaction 18:18:56.406 DRIVER resuming send queue 18:18:56.409 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 95 └─[WakeUpCCIntervalGet] 18:18:56.410 DRIVER workOffSendQueue > skipping because a transaction is pending 18:18:56.410 SERIAL » 0x0109001304028405255f18 (11 bytes) 18:18:56.414 SERIAL « [ACK] (0x06) 18:18:56.415 DRIVER ACK received from controller for current transaction 18:18:56.415 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.421 SERIAL « 0x01 (1 bytes) 18:18:56.422 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.425 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:56.423 SERIAL « 0x04011301e8 (5 bytes) 18:18:56.424 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:56.424 SERIAL » [ACK] (0x06) 18:18:56.425 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.438 SERIAL « 0x01 (1 bytes) 18:18:56.439 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.441 DRIVER « [REQ] [SendData] [confirmation] callbackId: 95 transmitStatus: OK 18:18:56.439 SERIAL « 0x0700135f000002b6 (8 bytes) 18:18:56.440 SERIAL Buffer := 0x010700135f000002b6 (9 bytes) 18:18:56.440 SERIAL » [ACK] (0x06) 18:18:56.442 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.441 DRIVER ACK received from node for current transaction. RTT = 32.56 ms 18:18:56.449 SERIAL « 0x01 (1 bytes) 18:18:56.449 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.452 CNTRLR [Node 004] [+] [Wake Up] wakeUpInterval: 300 [Endpoint 0] 18:18:56.457 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[WakeUpCCIntervalReport] payload: 0x00012c01 18:18:56.451 SERIAL « 0x0c0004000406840600012c015b (13 bytes) 18:18:56.451 SERIAL Buffer := 0x010c0004000406840600012c015b (14 bytes) 18:18:56.456 SERIAL » [ACK] (0x06) 18:18:56.459 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.454 CNTRLR [Node 004] [+] [Wake Up] controllerNodeId: 1 [Endpoint 0] 18:18:56.459 CNTRLR « [Node 004] received wakeup configuration: wakeup interval: 300 seconds controller node: 1 18:18:56.460 CNTRLR [Node 004] [+] [Wake Up] interviewComplete: true [Endpoint 0] [internal] 18:18:56.457 DRIVER ACK already received, resolving transaction 18:18:56.458 DRIVER resuming send queue 18:18:56.461 DRIVER The remaining 5 messages are for sleeping nodes, not sending anything! 18:18:56.461 DRIVER Send queue: (5 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 6, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] 18:18:56.494 CNTRLR [Node 004] BatteryCC: doing a complete interview... 18:18:56.497 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 96 └─[BatteryCCGet] 18:18:56.498 SERIAL » 0x0109001304028002256024 (11 bytes) 18:18:56.495 CNTRLR » [Node 004] querying battery status... 18:18:56.504 SERIAL « [ACK] (0x06) 18:18:56.504 DRIVER ACK received from controller for current transaction 18:18:56.505 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.509 SERIAL « 0x01 (1 bytes) 18:18:56.510 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.512 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:56.511 SERIAL « 0x04011301e8 (5 bytes) 18:18:56.511 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:56.512 SERIAL » [ACK] (0x06) 18:18:56.513 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.525 SERIAL « 0x01 (1 bytes) 18:18:56.526 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.527 SERIAL « 0x0700136000000289 (8 bytes) 18:18:56.528 DRIVER « [REQ] [SendData] [confirmation] callbackId: 96 transmitStatus: OK 18:18:56.528 SERIAL Buffer := 0x010700136000000289 (9 bytes) 18:18:56.528 SERIAL » [ACK] (0x06) 18:18:56.530 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.529 DRIVER ACK received from node for current transaction. RTT = 32.68 ms 18:18:56.536 SERIAL « 0x01 (1 bytes) 18:18:56.538 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.542 CNTRLR [Node 004] [~] [Battery] level: 40 => 40 [Endpoint 0] 18:18:56.545 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[BatteryCCReport] payload: 0x28 18:18:56.540 SERIAL « 0x0900040004038003285e (10 bytes) 18:18:56.540 SERIAL Buffer := 0x010900040004038003285e (11 bytes) 18:18:56.545 SERIAL » [ACK] (0x06) 18:18:56.547 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.546 DRIVER ACK already received, resolving transaction 18:18:56.546 DRIVER resuming send queue 18:18:56.552 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 97 └─[ThermostatSetpointCCGet] payload: 0x01 18:18:56.553 DRIVER workOffSendQueue > skipping because a transaction is pending 18:18:56.543 CNTRLR [Node 004] [~] [Battery] isLow: false => false [Endpoint 0] 18:18:56.548 CNTRLR « [Node 004] received response for battery information: level: 40 18:18:56.548 CNTRLR [Node 004] [+] [Battery] interviewComplete: true [Endpoint 0] [internal] 18:18:56.550 CNTRLR [Node 004] ThermostatSetpointCC: doing a complete interview... 18:18:56.550 CNTRLR » [Node 004] querying current value of setpoint Heating... 18:18:56.552 SERIAL » 0x010a001304034302012561e5 (12 bytes) 18:18:56.558 SERIAL « [ACK] (0x06) 18:18:56.558 DRIVER ACK received from controller for current transaction 18:18:56.559 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.565 SERIAL « 0x01 (1 bytes) 18:18:56.567 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.570 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:56.568 SERIAL « 0x04011301e8 (5 bytes) 18:18:56.568 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:56.569 SERIAL » [ACK] (0x06) 18:18:56.575 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.580 SERIAL « 0x01 (1 bytes) 18:18:56.580 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.582 SERIAL « 0x0700136100000288 (8 bytes) 18:18:56.584 DRIVER « [REQ] [SendData] [confirmation] callbackId: 97 transmitStatus: OK 18:18:56.583 SERIAL Buffer := 0x010700136100000288 (9 bytes) 18:18:56.583 SERIAL » [ACK] (0x06) 18:18:56.585 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.584 DRIVER ACK received from node for current transaction. RTT = 32.61 ms 18:18:56.592 SERIAL « 0x01 (1 bytes) 18:18:56.593 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.596 CNTRLR [Node 004] [~] [Thermostat Setpoint] setpoint[1]: 5 => 5 [Endpoint 0] 18:18:56.598 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[ThermostatSetpointCCReport] payload: 0x014201f4 18:18:56.594 SERIAL « 0x0c00040004064303014201f403 (13 bytes) 18:18:56.595 SERIAL Buffer := 0x010c00040004064303014201f403 (14 bytes) 18:18:56.598 SERIAL » [ACK] (0x06) 18:18:56.600 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.601 CNTRLR « [Node 004] received current value of setpoint Heating: 5 °C 18:18:56.601 CNTRLR » [Node 004] querying current value of setpoint Cooling... 18:18:56.599 DRIVER ACK already received, resolving transaction 18:18:56.600 DRIVER resuming send queue 18:18:56.603 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:18:56.604 DRIVER workOffSendQueue > skipping because a transaction is pending 18:18:56.603 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:18:56.607 SERIAL « [ACK] (0x06) 18:18:56.608 DRIVER ACK received from controller for current transaction 18:18:56.612 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.614 SERIAL « 0x01 (1 bytes) 18:18:56.614 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.620 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:56.618 SERIAL « 0x04011301e8 (5 bytes) 18:18:56.619 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:56.619 SERIAL » [ACK] (0x06) 18:18:56.621 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.631 SERIAL « 0x01 (1 bytes) 18:18:56.632 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:56.637 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:18:56.636 SERIAL « 0x070013620000028b (8 bytes) 18:18:56.636 SERIAL Buffer := 0x01070013620000028b (9 bytes) 18:18:56.637 SERIAL » [ACK] (0x06) 18:18:56.639 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:56.638 DRIVER ACK received from node for current transaction. RTT = 35.34 ms 18:18:57.674 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:18:58.174 DRIVER » [Node 004] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:18:58.175 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:18:58.178 SERIAL « [ACK] (0x06) 18:18:58.179 DRIVER ACK received from controller for current transaction 18:18:58.180 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:58.185 SERIAL « 0x01 (1 bytes) 18:18:58.185 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:58.187 SERIAL « 0x04011301e8 (5 bytes) 18:18:58.188 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:18:58.188 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:18:58.188 SERIAL » [ACK] (0x06) 18:18:58.189 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:58.202 SERIAL « 0x01 (1 bytes) 18:18:58.202 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:18:58.203 SERIAL « 0x070013620000038a (8 bytes) 18:18:58.205 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:18:58.204 SERIAL Buffer := 0x01070013620000038a (9 bytes) 18:18:58.204 SERIAL » [ACK] (0x06) 18:18:58.206 SERIAL The receive buffer is empty, waiting for the next chunk... 18:18:58.205 DRIVER ACK received from node for current transaction. RTT = 1602.89 ms 18:19:00.809 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:19:01.311 DRIVER » [Node 004] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:19:01.312 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:19:01.318 SERIAL « [ACK] (0x06) 18:19:01.319 DRIVER ACK received from controller for current transaction 18:19:01.320 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:01.329 SERIAL « 0x0104011301e8 (6 bytes) 18:19:01.332 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:19:01.330 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:19:01.331 SERIAL » [ACK] (0x06) 18:19:01.336 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:01.341 SERIAL « 0x01 (1 bytes) 18:19:01.341 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:01.346 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:19:01.343 SERIAL « 0x070013620000028b (8 bytes) 18:19:01.344 SERIAL Buffer := 0x01070013620000028b (9 bytes) 18:19:01.345 SERIAL » [ACK] (0x06) 18:19:01.349 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:01.347 DRIVER ACK received from node for current transaction. RTT = 4744.30 ms 18:19:06.600 DRIVER The awake timeout for node 4 has elapsed. Assuming it is asleep. 18:19:06.601 CNTRLR [Node 004] The node is now asleep. 18:19:06.602 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:19:06.603 DRIVER Send queue: (6 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 6, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:19:48.899 SERIAL « 0x01 (1 bytes) 18:19:48.899 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:48.902 CNTRLR [Node 006] [+] [Battery] level: 80 [Endpoint 0] 18:19:48.900 SERIAL « 0x09000400060380035024 (10 bytes) 18:19:48.901 SERIAL Buffer := 0x0109000400060380035024 (11 bytes) 18:19:48.905 SERIAL » [ACK] (0x06) 18:19:48.906 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:48.904 CNTRLR [Node 006] [+] [Battery] isLow: false [Endpoint 0] 18:19:48.921 SERIAL « 0x01 (1 bytes) 18:19:48.922 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:48.925 CNTRLR [Node 006] [Thermostat Setpoint] setpoint[1]: metadata updated [Endpoint 0] 18:19:48.924 SERIAL « 0x0c000400060643030142019065 (13 bytes) 18:19:48.924 SERIAL Buffer := 0x010c000400060643030142019065 (14 bytes) 18:19:48.929 SERIAL » [ACK] (0x06) 18:19:48.930 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:48.927 CNTRLR [Node 006] [+] [Thermostat Setpoint] setpoint[1]: 4 [Endpoint 0] 18:19:48.941 SERIAL « 0x01 (1 bytes) 18:19:48.941 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:48.944 CNTRLR [Node 006] [+] [Climate Control Schedule] overrideType: 0 [Endpoint 0] 18:19:48.942 SERIAL « 0x0a00040006044608007fc2 (11 bytes) 18:19:48.942 SERIAL Buffer := 0x010a00040006044608007fc2 (12 bytes) 18:19:48.947 SERIAL » [ACK] (0x06) 18:19:48.948 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:48.946 CNTRLR [Node 006] [+] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] 18:19:48.961 SERIAL « 0x01080004000602840774 (10 bytes) 18:19:48.964 CNTRLR « [Node 006] received wakeup notification 18:19:48.968 DRIVER » [Node 006] [REQ] [RequestNodeInfo] [P: WakeUp] payload: 0x06 18:19:48.962 SERIAL Buffer := 0x01080004000602840774 (10 bytes) 18:19:48.963 SERIAL » [ACK] (0x06) 18:19:48.966 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:48.968 SERIAL » 0x01040060069d (6 bytes) 18:19:48.965 CNTRLR [Node 006] The node is now awake. 18:19:48.972 SERIAL « [ACK] (0x06) 18:19:48.973 DRIVER Unexpected ACK received 18:19:48.974 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:48.979 SERIAL « 0x01 (1 bytes) 18:19:48.979 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:48.982 DRIVER « [RES] [RequestNodeInfo] [confirmation] payload: 0x01 18:19:48.980 SERIAL « 0x040160019b (5 bytes) 18:19:48.981 SERIAL Buffer := 0x01040160019b (6 bytes) 18:19:48.981 SERIAL » [ACK] (0x06) 18:19:48.983 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.112 SERIAL « 0x01 (1 bytes) 18:19:49.112 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.115 DRIVER « [Node 006] [REQ] [ApplicationUpdateRequest] [final] payload: 0x840610040804804681728f75438684ef46818f 18:19:49.117 CNTRLR « [Node 006] node info received supported CCs: · Battery · Climate Control Schedule · Clock · Manufacturer Specific · Multi Command · Protection · Thermostat Setpoint · Version · Wake Up controlled CCs: · Climate Control Schedule · Clock · Multi Command 18:19:49.113 SERIAL « 0x160049840610040804804681728f75438684ef46818f13 (23 bytes) 18:19:49.114 SERIAL Buffer := 0x01160049840610040804804681728f75438684ef46818f13 (24 bytes) 18:19:49.114 SERIAL » [ACK] (0x06) 18:19:49.118 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.116 DRIVER ACK already received, resolving transaction 18:19:49.117 DRIVER resuming send queue 18:19:49.119 DRIVER The remaining 5 messages are for sleeping nodes, not sending anything! 18:19:49.119 DRIVER Send queue: (5 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:19:49.144 CNTRLR [Node 006] Interview stage completed: NodeInfo 18:19:49.149 DRIVER » [Node 006] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 99 └─[ManufacturerSpecificCCGet] 18:19:49.150 SERIAL » 0x01090013060272042563d1 (11 bytes) 18:19:49.147 CNTRLR [Node 006] ManufacturerSpecificCC: doing a complete interview... 18:19:49.148 CNTRLR » [Node 006] querying manufacturer information... 18:19:49.154 SERIAL « [ACK] (0x06) 18:19:49.154 DRIVER ACK received from controller for current transaction 18:19:49.155 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.160 SERIAL « 0x01 (1 bytes) 18:19:49.161 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.164 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:19:49.163 SERIAL « 0x04011301e8 (5 bytes) 18:19:49.163 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:19:49.164 SERIAL » [ACK] (0x06) 18:19:49.164 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.178 SERIAL « 0x01 (1 bytes) 18:19:49.178 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.180 DRIVER « [REQ] [SendData] [confirmation] callbackId: 99 transmitStatus: OK 18:19:49.179 SERIAL « 0x070013630000028a (8 bytes) 18:19:49.179 SERIAL Buffer := 0x01070013630000028a (9 bytes) 18:19:49.180 SERIAL » [ACK] (0x06) 18:19:49.181 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.181 DRIVER ACK received from node for current transaction. RTT = 32.02 ms 18:19:49.188 SERIAL « 0x01 (1 bytes) 18:19:49.189 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.191 CNTRLR [Node 006] [+] [Manufacturer Specific] manufacturerId: 2 [Endpoint 0] 18:19:49.197 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[ManufacturerSpecificCCReport] payload: 0x000200050004 18:19:49.190 SERIAL « 0x0e000400060872050002000500048f (15 bytes) 18:19:49.190 SERIAL Buffer := 0x010e000400060872050002000500048f (16 bytes) 18:19:49.196 SERIAL » [ACK] (0x06) 18:19:49.198 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.203 SERIAL » 0x0109001306028611256437 (11 bytes) 18:19:49.193 CNTRLR [Node 006] [+] [Manufacturer Specific] productType: 5 [Endpoint 0] 18:19:49.195 CNTRLR [Node 006] [+] [Manufacturer Specific] productId: 4 [Endpoint 0] 18:19:49.199 CNTRLR « [Node 006] received response for manufacturer information: manufacturer: Danfoss (0x02) product type: 0x05 product id: 0x04 18:19:49.200 CNTRLR [Node 006] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 18:19:49.200 CNTRLR [Node 006] VersionCC: doing a complete interview... 18:19:49.201 CNTRLR » [Node 006] querying node versions... 18:19:49.197 DRIVER ACK already received, resolving transaction 18:19:49.198 DRIVER resuming send queue 18:19:49.202 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 100 └─[VersionCCGet] 18:19:49.203 DRIVER workOffSendQueue > skipping because a transaction is pending 18:19:49.211 SERIAL « [ACK] (0x06) 18:19:49.212 DRIVER ACK received from controller for current transaction 18:19:49.213 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.218 SERIAL « 0x0104011301e8 (6 bytes) 18:19:49.221 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:19:49.218 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:19:49.219 SERIAL » [ACK] (0x06) 18:19:49.222 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.231 SERIAL « 0x01 (1 bytes) 18:19:49.232 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.235 DRIVER « [REQ] [SendData] [confirmation] callbackId: 100 transmitStatus: OK 18:19:49.234 SERIAL « 0x070013640000028d (8 bytes) 18:19:49.234 SERIAL Buffer := 0x01070013640000028d (9 bytes) 18:19:49.234 SERIAL » [ACK] (0x06) 18:19:49.236 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.235 DRIVER ACK received from node for current transaction. RTT = 33.40 ms 18:19:49.242 SERIAL « 0x01 (1 bytes) 18:19:49.243 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.245 CNTRLR [Node 006] [+] [Version] libraryType: 6 [Endpoint 0] 18:19:49.252 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[VersionCCReport] payload: 0x0603430101 18:19:49.243 SERIAL « 0x0d00040006078612060343010125 (14 bytes) 18:19:49.244 SERIAL Buffer := 0x010d00040006078612060343010125 (15 bytes) 18:19:49.251 SERIAL » [ACK] (0x06) 18:19:49.254 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.257 SERIAL » 0x010a001306038613842565b2 (12 bytes) 18:19:49.247 CNTRLR [Node 006] [+] [Version] protocolVersion: "3.67" [Endpoint 0] 18:19:49.249 CNTRLR [Node 006] [+] [Version] firmwareVersions: 1.1 [Endpoint 0] 18:19:49.254 CNTRLR « [Node 006] received response for node versions: library type: Routing Slave (0x06) protocol version: 3.67 firmware versions: 1.1 18:19:49.255 CNTRLR » [Node 006] querying CC versions... 18:19:49.255 CNTRLR » [Node 006] querying the CC version for Wake Up (0x84)... 18:19:49.253 DRIVER ACK already received, resolving transaction 18:19:49.253 DRIVER resuming send queue 18:19:49.257 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 101 └─[VersionCCCommandClassGet] payload: 0x84 18:19:49.258 DRIVER workOffSendQueue > skipping because a transaction is pending 18:19:49.263 SERIAL « [ACK] (0x06) 18:19:49.263 DRIVER ACK received from controller for current transaction 18:19:49.264 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.270 SERIAL « 0x01 (1 bytes) 18:19:49.270 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.275 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:19:49.273 SERIAL « 0x04011301e8 (5 bytes) 18:19:49.274 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:19:49.274 SERIAL » [ACK] (0x06) 18:19:49.276 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.286 SERIAL « 0x01 (1 bytes) 18:19:49.287 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.290 DRIVER « [REQ] [SendData] [confirmation] callbackId: 101 transmitStatus: OK 18:19:49.289 SERIAL « 0x070013650000028c (8 bytes) 18:19:49.290 SERIAL Buffer := 0x01070013650000028c (9 bytes) 18:19:49.290 SERIAL » [ACK] (0x06) 18:19:49.292 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.291 DRIVER ACK received from node for current transaction. RTT = 34.48 ms 18:19:49.296 SERIAL « 0x01 (1 bytes) 18:19:49.296 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.299 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8402 18:19:49.301 CNTRLR [Node 006] supports CC Wake Up (0x84) in version 2 18:19:49.297 SERIAL « 0x0a000400060486148402e7 (11 bytes) 18:19:49.297 SERIAL Buffer := 0x010a000400060486148402e7 (12 bytes) 18:19:49.298 SERIAL » [ACK] (0x06) 18:19:49.300 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.299 DRIVER ACK already received, resolving transaction 18:19:49.300 DRIVER resuming send queue 18:19:49.303 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 102 └─[VersionCCCommandClassGet] payload: 0x80 18:19:49.304 DRIVER workOffSendQueue > skipping because a transaction is pending 18:19:49.301 CNTRLR » [Node 006] querying the CC version for Battery (0x80)... 18:19:49.304 SERIAL » 0x010a001306038613802566b5 (12 bytes) 18:19:49.308 SERIAL « [ACK] (0x06) 18:19:49.308 DRIVER ACK received from controller for current transaction 18:19:49.309 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.315 SERIAL « 0x01 (1 bytes) 18:19:49.315 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.318 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:19:49.316 SERIAL « 0x04011301e8 (5 bytes) 18:19:49.317 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:19:49.317 SERIAL » [ACK] (0x06) 18:19:49.318 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.331 SERIAL « 0x01 (1 bytes) 18:19:49.332 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.334 DRIVER « [REQ] [SendData] [confirmation] callbackId: 102 transmitStatus: OK 18:19:49.333 SERIAL « 0x070013660000038e (8 bytes) 18:19:49.333 SERIAL Buffer := 0x01070013660000038e (9 bytes) 18:19:49.334 SERIAL » [ACK] (0x06) 18:19:49.335 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.335 DRIVER ACK received from node for current transaction. RTT = 31.87 ms 18:19:49.342 SERIAL « 0x01 (1 bytes) 18:19:49.342 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.344 SERIAL « 0x0a000400060486148001e0 (11 bytes) 18:19:49.346 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8001 18:19:49.348 CNTRLR [Node 006] supports CC Battery (0x80) in version 1 18:19:49.346 DRIVER ACK already received, resolving transaction 18:19:49.347 DRIVER resuming send queue 18:19:49.352 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 103 └─[VersionCCCommandClassGet] payload: 0x72 18:19:49.353 DRIVER workOffSendQueue > skipping because a transaction is pending 18:19:49.345 SERIAL Buffer := 0x010a000400060486148001e0 (12 bytes) 18:19:49.345 SERIAL » [ACK] (0x06) 18:19:49.348 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.353 SERIAL » 0x010a00130603861372256746 (12 bytes) 18:19:49.349 CNTRLR [Node 006] skipping query for Climate Control Schedule (0x46) because max im plemented version is 1 18:19:49.349 CNTRLR [Node 006] skipping query for Clock (0x81) because max implemented version i s 0 18:19:49.350 CNTRLR » [Node 006] querying the CC version for Manufacturer Specific (0x72)... 18:19:49.382 SERIAL « [ACK] (0x06) 18:19:49.383 DRIVER ACK received from controller for current transaction 18:19:49.383 SERIAL « 0x060104011301e8 (7 bytes) 18:19:49.384 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:19:49.384 SERIAL » [ACK] (0x06) 18:19:49.385 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.384 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:19:49.391 SERIAL « 0x01 (1 bytes) 18:19:49.392 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.394 SERIAL « 0x070013670000028e (8 bytes) 18:19:49.395 DRIVER « [REQ] [SendData] [confirmation] callbackId: 103 transmitStatus: OK 18:19:49.394 SERIAL Buffer := 0x01070013670000028e (9 bytes) 18:19:49.395 SERIAL » [ACK] (0x06) 18:19:49.396 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.396 DRIVER ACK received from node for current transaction. RTT = 45.15 ms 18:19:49.400 SERIAL « 0x01 (1 bytes) 18:19:49.400 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.404 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x7201 18:19:49.406 CNTRLR [Node 006] supports CC Manufacturer Specific (0x72) in version 1 18:19:49.402 SERIAL « 0x0a00040006048614720112 (11 bytes) 18:19:49.403 SERIAL Buffer := 0x010a00040006048614720112 (12 bytes) 18:19:49.403 SERIAL » [ACK] (0x06) 18:19:49.405 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.409 SERIAL » 0x010a00130603861343256878 (12 bytes) 18:19:49.404 DRIVER ACK already received, resolving transaction 18:19:49.405 DRIVER resuming send queue 18:19:49.408 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 104 └─[VersionCCCommandClassGet] payload: 0x43 18:19:49.409 DRIVER workOffSendQueue > skipping because a transaction is pending 18:19:49.406 CNTRLR [Node 006] skipping query for Multi Command (0x8f) because max implemented v ersion is 1 18:19:49.406 CNTRLR [Node 006] skipping query for Protection (0x75) because max implemented vers ion is 0 18:19:49.407 CNTRLR » [Node 006] querying the CC version for Thermostat Setpoint (0x43)... 18:19:49.413 SERIAL « [ACK] (0x06) 18:19:49.414 DRIVER ACK received from controller for current transaction 18:19:49.414 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.420 SERIAL « 0x01 (1 bytes) 18:19:49.420 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.422 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:19:49.421 SERIAL « 0x04011301e8 (5 bytes) 18:19:49.422 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:19:49.422 SERIAL » [ACK] (0x06) 18:19:49.423 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.437 SERIAL « 0x01 (1 bytes) 18:19:49.437 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.439 DRIVER « [REQ] [SendData] [confirmation] callbackId: 104 transmitStatus: OK 18:19:49.438 SERIAL « 0x0700136800000281 (8 bytes) 18:19:49.438 SERIAL Buffer := 0x010700136800000281 (9 bytes) 18:19:49.439 SERIAL » [ACK] (0x06) 18:19:49.440 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.440 DRIVER ACK received from node for current transaction. RTT = 31.70 ms 18:19:49.447 SERIAL « 0x01 (1 bytes) 18:19:49.448 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.449 SERIAL « 0x0a00040006048614430220 (11 bytes) 18:19:49.451 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x4302 18:19:49.453 CNTRLR [Node 006] supports CC Thermostat Setpoint (0x43) in version 2 18:19:49.450 SERIAL Buffer := 0x010a00040006048614430220 (12 bytes) 18:19:49.451 SERIAL » [ACK] (0x06) 18:19:49.453 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.456 SERIAL » 0x010a001306038613862569bc (12 bytes) 18:19:49.452 DRIVER ACK already received, resolving transaction 18:19:49.452 DRIVER resuming send queue 18:19:49.456 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 105 └─[VersionCCCommandClassGet] payload: 0x86 18:19:49.456 DRIVER workOffSendQueue > skipping because a transaction is pending 18:19:49.454 CNTRLR » [Node 006] querying the CC version for Version (0x86)... 18:19:49.460 SERIAL « [ACK] (0x06) 18:19:49.461 DRIVER ACK received from controller for current transaction 18:19:49.461 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.467 SERIAL « 0x01 (1 bytes) 18:19:49.467 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.470 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:19:49.468 SERIAL « 0x04011301e8 (5 bytes) 18:19:49.469 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:19:49.469 SERIAL » [ACK] (0x06) 18:19:49.470 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.484 SERIAL « 0x01 (1 bytes) 18:19:49.484 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.486 DRIVER « [REQ] [SendData] [confirmation] callbackId: 105 transmitStatus: OK 18:19:49.485 SERIAL « 0x0700136900000381 (8 bytes) 18:19:49.485 SERIAL Buffer := 0x010700136900000381 (9 bytes) 18:19:49.486 SERIAL » [ACK] (0x06) 18:19:49.487 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.487 DRIVER ACK received from node for current transaction. RTT = 31.35 ms 18:19:49.495 SERIAL « 0x01 (1 bytes) 18:19:49.495 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.497 SERIAL « 0x0a000400060486148601e6 (11 bytes) 18:19:49.499 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8601 18:19:49.501 CNTRLR [Node 006] supports CC Version (0x86) in version 1 18:19:49.498 SERIAL Buffer := 0x010a000400060486148601e6 (12 bytes) 18:19:49.499 SERIAL » [ACK] (0x06) 18:19:49.501 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.500 DRIVER ACK already received, resolving transaction 18:19:49.500 DRIVER resuming send queue 18:19:49.504 DRIVER The remaining 5 messages are for sleeping nodes, not sending anything! 18:19:49.504 DRIVER Send queue: (5 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:19:49.502 CNTRLR [Node 006] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 18:19:49.503 CNTRLR [Node 006] trying to load device config 18:19:49.508 CNTRLR [Node 006] device config loaded 18:19:49.511 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 106 └─[WakeUpCCIntervalCapabilitiesGet] 18:19:49.512 SERIAL » 0x0109001306028409256a23 (11 bytes) 18:19:49.510 CNTRLR [Node 006] WakeUpCC: doing a complete interview... 18:19:49.510 CNTRLR » [Node 006] retrieving wakeup capabilities from the device... 18:19:49.515 SERIAL « [ACK] (0x06) 18:19:49.515 DRIVER ACK received from controller for current transaction 18:19:49.516 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.522 SERIAL « 0x01 (1 bytes) 18:19:49.522 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.524 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:19:49.523 SERIAL « 0x04011301e8 (5 bytes) 18:19:49.524 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:19:49.524 SERIAL » [ACK] (0x06) 18:19:49.525 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.538 SERIAL « 0x01 (1 bytes) 18:19:49.539 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.541 DRIVER « [REQ] [SendData] [confirmation] callbackId: 106 transmitStatus: OK 18:19:49.540 SERIAL « 0x0700136a00000283 (8 bytes) 18:19:49.540 SERIAL Buffer := 0x010700136a00000283 (9 bytes) 18:19:49.540 SERIAL » [ACK] (0x06) 18:19:49.542 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.541 DRIVER ACK received from node for current transaction. RTT = 30.30 ms 18:19:49.552 SERIAL « 0x01 (1 bytes) 18:19:49.552 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.553 SERIAL « 0x14000400060e840a00003c00070800012c00003c4b (21 bytes) 18:19:49.555 CNTRLR [Node 006] [Wake Up] wakeUpInterval: metadata updated [Endpoint 0] 18:19:49.557 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[WakeUpCCIntervalCapabilitiesReport] payload: 0x00003c00070800012c00003c 18:19:49.554 SERIAL Buffer := 0x0114000400060e840a00003c00070800012c00003c4b (22 bytes) 18:19:49.556 SERIAL » [ACK] (0x06) 18:19:49.558 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.561 SERIAL » 0x0109001306028405256b2e (11 bytes) 18:19:49.559 CNTRLR « [Node 006] received wakeup capabilities: default wakeup interval: 300 seconds minimum wakeup interval: 60 seconds maximum wakeup interval: 1800 seconds wakeup interval steps: 60 seconds 18:19:49.559 CNTRLR » [Node 006] retrieving wakeup interval from the device... 18:19:49.557 DRIVER ACK already received, resolving transaction 18:19:49.558 DRIVER resuming send queue 18:19:49.560 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 107 └─[WakeUpCCIntervalGet] 18:19:49.561 DRIVER workOffSendQueue > skipping because a transaction is pending 18:19:49.565 SERIAL « [ACK] (0x06) 18:19:49.565 DRIVER ACK received from controller for current transaction 18:19:49.566 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.571 SERIAL « 0x01 (1 bytes) 18:19:49.572 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.575 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:19:49.574 SERIAL « 0x04011301e8 (5 bytes) 18:19:49.574 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:19:49.575 SERIAL » [ACK] (0x06) 18:19:49.576 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.588 SERIAL « 0x0107 (2 bytes) 18:19:49.588 SERIAL [incomplete] Buffer := 0x0107 (2 bytes) 18:19:49.591 DRIVER « [REQ] [SendData] [confirmation] callbackId: 107 transmitStatus: OK 18:19:49.589 SERIAL « 0x00136b00000282 (7 bytes) 18:19:49.590 SERIAL Buffer := 0x010700136b00000282 (9 bytes) 18:19:49.590 SERIAL » [ACK] (0x06) 18:19:49.592 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.591 DRIVER ACK received from node for current transaction. RTT = 31.29 ms 18:19:49.600 SERIAL « 0x01 (1 bytes) 18:19:49.600 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.603 CNTRLR [Node 006] [+] [Wake Up] wakeUpInterval: 300 [Endpoint 0] 18:19:49.607 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[WakeUpCCIntervalReport] payload: 0x00012c01 18:19:49.602 SERIAL « 0x0c0004000606840600012c0159 (13 bytes) 18:19:49.602 SERIAL Buffer := 0x010c0004000606840600012c0159 (14 bytes) 18:19:49.607 SERIAL » [ACK] (0x06) 18:19:49.609 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.605 CNTRLR [Node 006] [+] [Wake Up] controllerNodeId: 1 [Endpoint 0] 18:19:49.609 CNTRLR « [Node 006] received wakeup configuration: wakeup interval: 300 seconds controller node: 1 18:19:49.610 CNTRLR [Node 006] [+] [Wake Up] interviewComplete: true [Endpoint 0] [internal] 18:19:49.608 DRIVER ACK already received, resolving transaction 18:19:49.608 DRIVER resuming send queue 18:19:49.611 DRIVER The remaining 5 messages are for sleeping nodes, not sending anything! 18:19:49.612 DRIVER Send queue: (5 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:19:49.647 CNTRLR [Node 006] BatteryCC: doing a complete interview... 18:19:49.649 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 108 └─[BatteryCCGet] 18:19:49.650 SERIAL » 0x0109001306028002256c2a (11 bytes) 18:19:49.647 CNTRLR » [Node 006] querying battery status... 18:19:49.655 SERIAL « [ACK] (0x06) 18:19:49.655 DRIVER ACK received from controller for current transaction 18:19:49.656 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.661 SERIAL « 0x01 (1 bytes) 18:19:49.662 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.663 SERIAL « 0x04011301e8 (5 bytes) 18:19:49.664 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:19:49.664 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:19:49.664 SERIAL » [ACK] (0x06) 18:19:49.665 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.678 SERIAL « 0x01 (1 bytes) 18:19:49.678 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.680 SERIAL « 0x0700136c00000285 (8 bytes) 18:19:49.682 DRIVER « [REQ] [SendData] [confirmation] callbackId: 108 transmitStatus: OK 18:19:49.681 SERIAL Buffer := 0x010700136c00000285 (9 bytes) 18:19:49.681 SERIAL » [ACK] (0x06) 18:19:49.684 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.683 DRIVER ACK received from node for current transaction. RTT = 33.90 ms 18:19:49.688 SERIAL « 0x01 (1 bytes) 18:19:49.688 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.690 SERIAL « 0x09000400060380035024 (10 bytes) 18:19:49.692 CNTRLR [Node 006] [~] [Battery] level: 80 => 80 [Endpoint 0] 18:19:49.696 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[BatteryCCReport] payload: 0x50 18:19:49.691 SERIAL Buffer := 0x0109000400060380035024 (11 bytes) 18:19:49.695 SERIAL » [ACK] (0x06) 18:19:49.698 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.703 SERIAL » 0x010a00130603430201256deb (12 bytes) 18:19:49.694 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 0] 18:19:49.698 CNTRLR « [Node 006] received response for battery information: level: 80 18:19:49.699 CNTRLR [Node 006] [+] [Battery] interviewComplete: true [Endpoint 0] [internal] 18:19:49.700 CNTRLR [Node 006] ThermostatSetpointCC: doing a complete interview... 18:19:49.701 CNTRLR » [Node 006] querying current value of setpoint Heating... 18:19:49.697 DRIVER ACK already received, resolving transaction 18:19:49.697 DRIVER resuming send queue 18:19:49.702 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 109 └─[ThermostatSetpointCCGet] payload: 0x01 18:19:49.704 DRIVER workOffSendQueue > skipping because a transaction is pending 18:19:49.708 SERIAL « [ACK] (0x06) 18:19:49.711 DRIVER ACK received from controller for current transaction 18:19:49.713 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.731 SERIAL « 0x0104011301e8 (6 bytes) 18:19:49.733 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:19:49.732 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:19:49.732 SERIAL » [ACK] (0x06) 18:19:49.734 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.743 SERIAL « 0x01 (1 bytes) 18:19:49.743 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.745 DRIVER « [REQ] [SendData] [confirmation] callbackId: 109 transmitStatus: OK 18:19:49.744 SERIAL « 0x0700136d00000385 (8 bytes) 18:19:49.745 SERIAL Buffer := 0x010700136d00000385 (9 bytes) 18:19:49.745 SERIAL » [ACK] (0x06) 18:19:49.746 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.746 DRIVER ACK received from node for current transaction. RTT = 44.02 ms 18:19:49.749 SERIAL « 0x01 (1 bytes) 18:19:49.750 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.752 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpoint[1]: 4 => 4 [Endpoint 0] 18:19:49.754 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[ThermostatSetpointCCReport] payload: 0x01420190 18:19:49.751 SERIAL « 0x0c000400060643030142019065 (13 bytes) 18:19:49.751 SERIAL Buffer := 0x010c000400060643030142019065 (14 bytes) 18:19:49.754 SERIAL » [ACK] (0x06) 18:19:49.756 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.759 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:19:49.756 CNTRLR « [Node 006] received current value of setpoint Heating: 4 °C 18:19:49.757 CNTRLR » [Node 006] querying current value of setpoint Cooling... 18:19:49.755 DRIVER ACK already received, resolving transaction 18:19:49.755 DRIVER resuming send queue 18:19:49.758 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:19:49.759 DRIVER workOffSendQueue > skipping because a transaction is pending 18:19:49.763 SERIAL « [ACK] (0x06) 18:19:49.764 DRIVER ACK received from controller for current transaction 18:19:49.764 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.771 SERIAL « 0x01 (1 bytes) 18:19:49.771 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.773 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:19:49.772 SERIAL « 0x04011301e8 (5 bytes) 18:19:49.772 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:19:49.773 SERIAL » [ACK] (0x06) 18:19:49.775 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:49.787 SERIAL « 0x01 (1 bytes) 18:19:49.788 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:49.789 SERIAL « 0x0700136e00000287 (8 bytes) 18:19:49.790 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:19:49.790 DRIVER ACK received from node for current transaction. RTT = 32.75 ms 18:19:49.789 SERIAL Buffer := 0x010700136e00000287 (9 bytes) 18:19:49.790 SERIAL » [ACK] (0x06) 18:19:49.791 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:50.823 CNTRLR [Node 006] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:19:51.324 DRIVER » [Node 006] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:19:51.325 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:19:51.329 SERIAL « [ACK] (0x06) 18:19:51.330 DRIVER ACK received from controller for current transaction 18:19:51.330 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:51.337 SERIAL « 0x01 (1 bytes) 18:19:51.339 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:51.342 SERIAL « 0x04011301e8 (5 bytes) 18:19:51.344 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:19:51.342 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:19:51.343 SERIAL » [ACK] (0x06) 18:19:51.344 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:51.353 SERIAL « 0x01 (1 bytes) 18:19:51.354 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:51.356 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:19:51.355 SERIAL « 0x0700136e00000386 (8 bytes) 18:19:51.355 SERIAL Buffer := 0x010700136e00000386 (9 bytes) 18:19:51.356 SERIAL » [ACK] (0x06) 18:19:51.357 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:51.357 DRIVER ACK received from node for current transaction. RTT = 1598.97 ms 18:19:53.957 CNTRLR [Node 006] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:19:54.457 DRIVER » [Node 006] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:19:54.458 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:19:54.465 SERIAL « [ACK] (0x06) 18:19:54.465 DRIVER ACK received from controller for current transaction 18:19:54.466 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:54.471 SERIAL « 0x01 (1 bytes) 18:19:54.471 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:54.474 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:19:54.473 SERIAL « 0x04011301e8 (5 bytes) 18:19:54.473 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:19:54.473 SERIAL » [ACK] (0x06) 18:19:54.476 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:54.487 SERIAL « 0x01 (1 bytes) 18:19:54.488 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:19:54.490 SERIAL « 0x0700136e00000287 (8 bytes) 18:19:54.492 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:19:54.491 SERIAL Buffer := 0x010700136e00000287 (9 bytes) 18:19:54.491 SERIAL » [ACK] (0x06) 18:19:54.493 SERIAL The receive buffer is empty, waiting for the next chunk... 18:19:54.492 DRIVER ACK received from node for current transaction. RTT = 4734.41 ms 18:19:59.756 DRIVER The awake timeout for node 6 has elapsed. Assuming it is asleep. 18:19:59.757 CNTRLR [Node 006] The node is now asleep. 18:19:59.758 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:19:59.759 DRIVER Send queue: (6 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] 18:20:12.299 SERIAL « 0x01 (1 bytes) 18:20:12.300 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.304 CNTRLR [Node 003] [+] [Battery] level: 51 [Endpoint 0] 18:20:12.302 SERIAL « 0x09000400030380033342 (10 bytes) 18:20:12.302 SERIAL Buffer := 0x0109000400030380033342 (11 bytes) 18:20:12.307 SERIAL » [ACK] (0x06) 18:20:12.308 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.306 CNTRLR [Node 003] [+] [Battery] isLow: false [Endpoint 0] 18:20:12.321 SERIAL « 0x01 (1 bytes) 18:20:12.322 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.328 CNTRLR [Node 003] [Thermostat Setpoint] setpoint[1]: metadata updated [Endpoint 0] 18:20:12.327 SERIAL « 0x0c0004000306430301420708fe (13 bytes) 18:20:12.327 SERIAL Buffer := 0x010c0004000306430301420708fe (14 bytes) 18:20:12.331 SERIAL » [ACK] (0x06) 18:20:12.332 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.330 CNTRLR [Node 003] [+] [Thermostat Setpoint] setpoint[1]: 18 [Endpoint 0] 18:20:12.343 SERIAL « 0x01 (1 bytes) 18:20:12.343 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.346 CNTRLR [Node 003] [+] [Climate Control Schedule] overrideType: 0 [Endpoint 0] 18:20:12.345 SERIAL « 0x0a00040003044608007fc7 (11 bytes) 18:20:12.345 SERIAL Buffer := 0x010a00040003044608007fc7 (12 bytes) 18:20:12.350 SERIAL » [ACK] (0x06) 18:20:12.350 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.348 CNTRLR [Node 003] [+] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] 18:20:12.366 SERIAL « 0x01080004000302840771 (10 bytes) 18:20:12.367 CNTRLR « [Node 003] received wakeup notification 18:20:12.370 DRIVER » [Node 003] [REQ] [RequestNodeInfo] [P: WakeUp] payload: 0x03 18:20:12.366 SERIAL Buffer := 0x01080004000302840771 (10 bytes) 18:20:12.367 SERIAL » [ACK] (0x06) 18:20:12.369 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.371 SERIAL » 0x010400600398 (6 bytes) 18:20:12.368 CNTRLR [Node 003] The node is now awake. 18:20:12.376 SERIAL « [ACK] (0x06) 18:20:12.377 DRIVER ACK received from controller for current transaction 18:20:12.377 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.383 SERIAL « 0x01 (1 bytes) 18:20:12.383 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.386 DRIVER « [RES] [RequestNodeInfo] [confirmation] payload: 0x01 18:20:12.384 SERIAL « 0x040160019b (5 bytes) 18:20:12.385 SERIAL Buffer := 0x01040160019b (6 bytes) 18:20:12.385 SERIAL » [ACK] (0x06) 18:20:12.386 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.517 SERIAL « 0x01 (1 bytes) 18:20:12.517 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.522 DRIVER « [Node 003] [REQ] [ApplicationUpdateRequest] [final] payload: 0x840310040804804681728f75438684ef46818f 18:20:12.524 CNTRLR « [Node 003] node info received supported CCs: · Battery · Climate Control Schedule · Clock · Manufacturer Specific · Multi Command · Protection · Thermostat Setpoint · Version · Wake Up controlled CCs: · Climate Control Schedule · Clock · Multi Command 18:20:12.518 SERIAL « 0x160049840310040804804681728f75438684ef46818f16 (23 bytes) 18:20:12.519 SERIAL Buffer := 0x01160049840310040804804681728f75438684ef46818f16 (24 bytes) 18:20:12.519 SERIAL » [ACK] (0x06) 18:20:12.525 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.523 DRIVER ACK already received, resolving transaction 18:20:12.523 DRIVER resuming send queue 18:20:12.526 DRIVER The remaining 5 messages are for sleeping nodes, not sending anything! 18:20:12.526 DRIVER Send queue: (5 messages) · [REQ] RequestNodeInfo [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] 18:20:12.563 CNTRLR [Node 003] Interview stage completed: NodeInfo 18:20:12.567 DRIVER » [Node 003] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 111 └─[ManufacturerSpecificCCGet] 18:20:12.567 SERIAL » 0x0109001303027204256fd8 (11 bytes) 18:20:12.565 CNTRLR [Node 003] ManufacturerSpecificCC: doing a complete interview... 18:20:12.566 CNTRLR » [Node 003] querying manufacturer information... 18:20:12.570 SERIAL « [ACK] (0x06) 18:20:12.571 DRIVER ACK received from controller for current transaction 18:20:12.572 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.577 SERIAL « 0x01 (1 bytes) 18:20:12.578 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.582 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:20:12.579 SERIAL « 0x04011301e8 (5 bytes) 18:20:12.580 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:20:12.581 SERIAL » [ACK] (0x06) 18:20:12.582 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.594 SERIAL « 0x01 (1 bytes) 18:20:12.595 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.598 DRIVER « [REQ] [SendData] [confirmation] callbackId: 111 transmitStatus: OK 18:20:12.598 DRIVER ACK received from node for current transaction. RTT = 31.70 ms 18:20:12.596 SERIAL « 0x0700136f00000286 (8 bytes) 18:20:12.597 SERIAL Buffer := 0x010700136f00000286 (9 bytes) 18:20:12.597 SERIAL » [ACK] (0x06) 18:20:12.599 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.606 SERIAL « 0x01 (1 bytes) 18:20:12.606 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.608 SERIAL « 0x0e000400030872050002000500048a (15 bytes) 18:20:12.609 CNTRLR [Node 003] [+] [Manufacturer Specific] manufacturerId: 2 [Endpoint 0] 18:20:12.615 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[ManufacturerSpecificCCReport] payload: 0x000200050004 18:20:12.608 SERIAL Buffer := 0x010e000400030872050002000500048a (16 bytes) 18:20:12.614 SERIAL » [ACK] (0x06) 18:20:12.620 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.624 SERIAL » 0x0109001303028611257026 (11 bytes) 18:20:12.611 CNTRLR [Node 003] [+] [Manufacturer Specific] productType: 5 [Endpoint 0] 18:20:12.613 CNTRLR [Node 003] [+] [Manufacturer Specific] productId: 4 [Endpoint 0] 18:20:12.620 CNTRLR « [Node 003] received response for manufacturer information: manufacturer: Danfoss (0x02) product type: 0x05 product id: 0x04 18:20:12.621 CNTRLR [Node 003] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 18:20:12.622 CNTRLR [Node 003] VersionCC: doing a complete interview... 18:20:12.622 CNTRLR » [Node 003] querying node versions... 18:20:12.615 DRIVER ACK already received, resolving transaction 18:20:12.619 DRIVER resuming send queue 18:20:12.624 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 112 └─[VersionCCGet] 18:20:12.625 DRIVER workOffSendQueue > skipping because a transaction is pending 18:20:12.629 SERIAL « [ACK] (0x06) 18:20:12.630 DRIVER ACK received from controller for current transaction 18:20:12.632 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.645 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:20:12.643 SERIAL « 0x0104011301e8 (6 bytes) 18:20:12.643 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:20:12.643 SERIAL » [ACK] (0x06) 18:20:12.645 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.653 SERIAL « 0x01 (1 bytes) 18:20:12.654 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.656 DRIVER « [REQ] [SendData] [confirmation] callbackId: 112 transmitStatus: OK 18:20:12.655 SERIAL « 0x0700137000000398 (8 bytes) 18:20:12.656 SERIAL Buffer := 0x010700137000000398 (9 bytes) 18:20:12.656 SERIAL » [ACK] (0x06) 18:20:12.657 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.657 DRIVER ACK received from node for current transaction. RTT = 33.14 ms 18:20:12.664 SERIAL « 0x01 (1 bytes) 18:20:12.665 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.667 CNTRLR [Node 003] [+] [Version] libraryType: 6 [Endpoint 0] 18:20:12.673 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[VersionCCReport] payload: 0x0603430101 18:20:12.665 SERIAL « 0x0d00040003078612060343010120 (14 bytes) 18:20:12.666 SERIAL Buffer := 0x010d00040003078612060343010120 (15 bytes) 18:20:12.672 SERIAL » [ACK] (0x06) 18:20:12.677 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.680 SERIAL » 0x010a001303038613842571a3 (12 bytes) 18:20:12.669 CNTRLR [Node 003] [+] [Version] protocolVersion: "3.67" [Endpoint 0] 18:20:12.671 CNTRLR [Node 003] [+] [Version] firmwareVersions: 1.1 [Endpoint 0] 18:20:12.677 CNTRLR « [Node 003] received response for node versions: library type: Routing Slave (0x06) protocol version: 3.67 firmware versions: 1.1 18:20:12.677 CNTRLR » [Node 003] querying CC versions... 18:20:12.678 CNTRLR » [Node 003] querying the CC version for Wake Up (0x84)... 18:20:12.674 DRIVER ACK already received, resolving transaction 18:20:12.676 DRIVER resuming send queue 18:20:12.679 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 113 └─[VersionCCCommandClassGet] payload: 0x84 18:20:12.680 DRIVER workOffSendQueue > skipping because a transaction is pending 18:20:12.685 SERIAL « [ACK] (0x06) 18:20:12.685 DRIVER ACK received from controller for current transaction 18:20:12.686 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.691 SERIAL « 0x01 (1 bytes) 18:20:12.692 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.698 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:20:12.696 SERIAL « 0x04011301e8 (5 bytes) 18:20:12.697 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:20:12.697 SERIAL » [ACK] (0x06) 18:20:12.699 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.707 SERIAL « 0x01 (1 bytes) 18:20:12.708 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.710 SERIAL « 0x0700137100000298 (8 bytes) 18:20:12.712 DRIVER « [REQ] [SendData] [confirmation] callbackId: 113 transmitStatus: OK 18:20:12.710 SERIAL Buffer := 0x010700137100000298 (9 bytes) 18:20:12.711 SERIAL » [ACK] (0x06) 18:20:12.713 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.712 DRIVER ACK received from node for current transaction. RTT = 33.23 ms 18:20:12.718 SERIAL « 0x01 (1 bytes) 18:20:12.719 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.720 SERIAL « 0x0a000400030486148402e2 (11 bytes) 18:20:12.722 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8402 18:20:12.724 CNTRLR [Node 003] supports CC Wake Up (0x84) in version 2 18:20:12.721 SERIAL Buffer := 0x010a000400030486148402e2 (12 bytes) 18:20:12.721 SERIAL » [ACK] (0x06) 18:20:12.724 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.727 SERIAL » 0x010a001303038613802572a4 (12 bytes) 18:20:12.723 DRIVER ACK already received, resolving transaction 18:20:12.723 DRIVER resuming send queue 18:20:12.727 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 114 └─[VersionCCCommandClassGet] payload: 0x80 18:20:12.727 DRIVER workOffSendQueue > skipping because a transaction is pending 18:20:12.725 CNTRLR » [Node 003] querying the CC version for Battery (0x80)... 18:20:12.732 SERIAL « [ACK] (0x06) 18:20:12.732 DRIVER ACK received from controller for current transaction 18:20:12.733 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.738 SERIAL « 0x01 (1 bytes) 18:20:12.740 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.743 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:20:12.741 SERIAL « 0x04011301e8 (5 bytes) 18:20:12.741 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:20:12.742 SERIAL » [ACK] (0x06) 18:20:12.743 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.755 SERIAL « 0x01 (1 bytes) 18:20:12.755 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.758 DRIVER « [REQ] [SendData] [confirmation] callbackId: 114 transmitStatus: OK 18:20:12.757 SERIAL « 0x070013720000029b (8 bytes) 18:20:12.757 SERIAL Buffer := 0x01070013720000029b (9 bytes) 18:20:12.757 SERIAL » [ACK] (0x06) 18:20:12.759 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.758 DRIVER ACK received from node for current transaction. RTT = 32.06 ms 18:20:12.768 SERIAL « 0x01 (1 bytes) 18:20:12.769 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.772 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8001 18:20:12.774 CNTRLR [Node 003] supports CC Battery (0x80) in version 1 18:20:12.770 SERIAL « 0x0a000400030486148001e5 (11 bytes) 18:20:12.770 SERIAL Buffer := 0x010a000400030486148001e5 (12 bytes) 18:20:12.771 SERIAL » [ACK] (0x06) 18:20:12.774 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.773 DRIVER ACK already received, resolving transaction 18:20:12.773 DRIVER resuming send queue 18:20:12.778 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 115 └─[VersionCCCommandClassGet] payload: 0x72 18:20:12.779 DRIVER workOffSendQueue > skipping because a transaction is pending 18:20:12.775 CNTRLR [Node 003] skipping query for Climate Control Schedule (0x46) because max im plemented version is 1 18:20:12.776 CNTRLR [Node 003] skipping query for Clock (0x81) because max implemented version i s 0 18:20:12.776 CNTRLR » [Node 003] querying the CC version for Manufacturer Specific (0x72)... 18:20:12.779 SERIAL » 0x010a00130303861372257357 (12 bytes) 18:20:12.812 SERIAL « [ACK] (0x06) 18:20:12.813 DRIVER ACK received from controller for current transaction 18:20:12.813 SERIAL « 0x060104011301e8 (7 bytes) 18:20:12.814 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:20:12.814 SERIAL » [ACK] (0x06) 18:20:12.815 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.814 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:20:12.818 SERIAL « 0x01 (1 bytes) 18:20:12.819 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.821 DRIVER « [REQ] [SendData] [confirmation] callbackId: 115 transmitStatus: OK 18:20:12.820 SERIAL « 0x070013730000029a (8 bytes) 18:20:12.821 SERIAL Buffer := 0x01070013730000029a (9 bytes) 18:20:12.821 SERIAL » [ACK] (0x06) 18:20:12.826 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.822 DRIVER ACK received from node for current transaction. RTT = 43.94 ms 18:20:12.828 SERIAL « 0x01 (1 bytes) 18:20:12.828 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.831 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x7201 18:20:12.834 CNTRLR [Node 003] supports CC Manufacturer Specific (0x72) in version 1 18:20:12.829 SERIAL « 0x0a00040003048614720117 (11 bytes) 18:20:12.829 SERIAL Buffer := 0x010a00040003048614720117 (12 bytes) 18:20:12.830 SERIAL » [ACK] (0x06) 18:20:12.833 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.837 SERIAL » 0x010a00130303861343257461 (12 bytes) 18:20:12.832 DRIVER ACK already received, resolving transaction 18:20:12.833 DRIVER resuming send queue 18:20:12.837 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 116 └─[VersionCCCommandClassGet] payload: 0x43 18:20:12.837 DRIVER workOffSendQueue > skipping because a transaction is pending 18:20:12.834 CNTRLR [Node 003] skipping query for Multi Command (0x8f) because max implemented v ersion is 1 18:20:12.835 CNTRLR [Node 003] skipping query for Protection (0x75) because max implemented vers ion is 0 18:20:12.835 CNTRLR » [Node 003] querying the CC version for Thermostat Setpoint (0x43)... 18:20:12.841 SERIAL « [ACK] (0x06) 18:20:12.842 DRIVER ACK received from controller for current transaction 18:20:12.842 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.850 SERIAL « 0x0104011301e8 (6 bytes) 18:20:12.851 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:20:12.850 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:20:12.851 SERIAL » [ACK] (0x06) 18:20:12.852 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.866 SERIAL « 0x01 (1 bytes) 18:20:12.866 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.871 DRIVER « [REQ] [SendData] [confirmation] callbackId: 116 transmitStatus: OK 18:20:12.870 SERIAL « 0x070013740000029d (8 bytes) 18:20:12.870 SERIAL Buffer := 0x01070013740000029d (9 bytes) 18:20:12.870 SERIAL » [ACK] (0x06) 18:20:12.873 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.872 DRIVER ACK received from node for current transaction. RTT = 35.87 ms 18:20:12.876 SERIAL « 0x01 (1 bytes) 18:20:12.877 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.879 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x4302 18:20:12.881 CNTRLR [Node 003] supports CC Thermostat Setpoint (0x43) in version 2 18:20:12.877 SERIAL « 0x0a00040003048614430225 (11 bytes) 18:20:12.878 SERIAL Buffer := 0x010a00040003048614430225 (12 bytes) 18:20:12.878 SERIAL » [ACK] (0x06) 18:20:12.880 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.883 SERIAL » 0x010a001303038613862575a5 (12 bytes) 18:20:12.879 DRIVER ACK already received, resolving transaction 18:20:12.880 DRIVER resuming send queue 18:20:12.883 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 117 └─[VersionCCCommandClassGet] payload: 0x86 18:20:12.884 DRIVER workOffSendQueue > skipping because a transaction is pending 18:20:12.881 CNTRLR » [Node 003] querying the CC version for Version (0x86)... 18:20:12.887 SERIAL « [ACK] (0x06) 18:20:12.888 DRIVER ACK received from controller for current transaction 18:20:12.888 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.894 SERIAL « 0x01 (1 bytes) 18:20:12.894 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.896 SERIAL « 0x04011301e8 (5 bytes) 18:20:12.898 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:20:12.897 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:20:12.897 SERIAL » [ACK] (0x06) 18:20:12.898 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.911 SERIAL « 0x01 (1 bytes) 18:20:12.911 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.914 SERIAL « 0x070013750000029c (8 bytes) 18:20:12.915 DRIVER « [REQ] [SendData] [confirmation] callbackId: 117 transmitStatus: OK 18:20:12.914 SERIAL Buffer := 0x01070013750000029c (9 bytes) 18:20:12.915 SERIAL » [ACK] (0x06) 18:20:12.917 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.916 DRIVER ACK received from node for current transaction. RTT = 33.40 ms 18:20:12.922 SERIAL « 0x01 (1 bytes) 18:20:12.922 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.926 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8601 18:20:12.929 CNTRLR [Node 003] supports CC Version (0x86) in version 1 18:20:12.923 SERIAL « 0x0a000400030486148601e3 (11 bytes) 18:20:12.925 SERIAL Buffer := 0x010a000400030486148601e3 (12 bytes) 18:20:12.925 SERIAL » [ACK] (0x06) 18:20:12.928 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.926 DRIVER ACK already received, resolving transaction 18:20:12.927 DRIVER resuming send queue 18:20:12.931 DRIVER The remaining 5 messages are for sleeping nodes, not sending anything! 18:20:12.931 DRIVER Send queue: (5 messages) · [REQ] RequestNodeInfo [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] 18:20:12.929 CNTRLR [Node 003] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 18:20:12.930 CNTRLR [Node 003] trying to load device config 18:20:12.934 CNTRLR [Node 003] device config loaded 18:20:12.937 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 118 └─[WakeUpCCIntervalCapabilitiesGet] 18:20:12.938 SERIAL » 0x010900130302840925763a (11 bytes) 18:20:12.936 CNTRLR [Node 003] WakeUpCC: doing a complete interview... 18:20:12.936 CNTRLR » [Node 003] retrieving wakeup capabilities from the device... 18:20:12.941 SERIAL « [ACK] (0x06) 18:20:12.941 DRIVER ACK received from controller for current transaction 18:20:12.942 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.948 SERIAL « 0x01 (1 bytes) 18:20:12.948 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.950 SERIAL « 0x04011301e8 (5 bytes) 18:20:12.951 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:20:12.950 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:20:12.951 SERIAL » [ACK] (0x06) 18:20:12.952 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.964 SERIAL « 0x0107 (2 bytes) 18:20:12.965 SERIAL [incomplete] Buffer := 0x0107 (2 bytes) 18:20:12.967 DRIVER « [REQ] [SendData] [confirmation] callbackId: 118 transmitStatus: OK 18:20:12.966 SERIAL « 0x0013760000029f (7 bytes) 18:20:12.966 SERIAL Buffer := 0x01070013760000029f (9 bytes) 18:20:12.966 SERIAL » [ACK] (0x06) 18:20:12.968 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.967 DRIVER ACK received from node for current transaction. RTT = 30.42 ms 18:20:12.978 SERIAL « 0x01 (1 bytes) 18:20:12.979 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:12.981 CNTRLR [Node 003] [Wake Up] wakeUpInterval: metadata updated [Endpoint 0] 18:20:12.983 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[WakeUpCCIntervalCapabilitiesReport] payload: 0x00003c00070800012c00003c 18:20:12.980 SERIAL « 0x14000400030e840a00003c00070800012c00003c4e (21 bytes) 18:20:12.980 SERIAL Buffer := 0x0114000400030e840a00003c00070800012c00003c4e (22 bytes) 18:20:12.982 SERIAL » [ACK] (0x06) 18:20:12.985 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.985 CNTRLR « [Node 003] received wakeup capabilities: default wakeup interval: 300 seconds minimum wakeup interval: 60 seconds maximum wakeup interval: 1800 seconds wakeup interval steps: 60 seconds 18:20:12.985 CNTRLR » [Node 003] retrieving wakeup interval from the device... 18:20:12.984 DRIVER ACK already received, resolving transaction 18:20:12.984 DRIVER resuming send queue 18:20:12.987 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 119 └─[WakeUpCCIntervalGet] 18:20:12.988 DRIVER workOffSendQueue > skipping because a transaction is pending 18:20:12.988 SERIAL » 0x0109001303028405257737 (11 bytes) 18:20:12.993 SERIAL « [ACK] (0x06) 18:20:12.994 DRIVER ACK received from controller for current transaction 18:20:12.994 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:12.999 SERIAL « 0x01 (1 bytes) 18:20:12.999 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:13.005 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:20:13.003 SERIAL « 0x04011301e8 (5 bytes) 18:20:13.004 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:20:13.004 SERIAL » [ACK] (0x06) 18:20:13.008 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:13.016 SERIAL « 0x01 (1 bytes) 18:20:13.016 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:13.019 DRIVER « [REQ] [SendData] [confirmation] callbackId: 119 transmitStatus: OK 18:20:13.017 SERIAL « 0x070013770000029e (8 bytes) 18:20:13.018 SERIAL Buffer := 0x01070013770000029e (9 bytes) 18:20:13.018 SERIAL » [ACK] (0x06) 18:20:13.020 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:13.019 DRIVER ACK received from node for current transaction. RTT = 32.17 ms 18:20:13.026 SERIAL « 0x01 (1 bytes) 18:20:13.027 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:13.029 CNTRLR [Node 003] [+] [Wake Up] wakeUpInterval: 300 [Endpoint 0] 18:20:13.034 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[WakeUpCCIntervalReport] payload: 0x00012c01 18:20:13.028 SERIAL « 0x0c0004000306840600012c015c (13 bytes) 18:20:13.028 SERIAL Buffer := 0x010c0004000306840600012c015c (14 bytes) 18:20:13.032 SERIAL » [ACK] (0x06) 18:20:13.036 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:13.031 CNTRLR [Node 003] [+] [Wake Up] controllerNodeId: 1 [Endpoint 0] 18:20:13.036 CNTRLR « [Node 003] received wakeup configuration: wakeup interval: 300 seconds controller node: 1 18:20:13.037 CNTRLR [Node 003] [+] [Wake Up] interviewComplete: true [Endpoint 0] [internal] 18:20:13.035 DRIVER ACK already received, resolving transaction 18:20:13.035 DRIVER resuming send queue 18:20:13.038 DRIVER The remaining 5 messages are for sleeping nodes, not sending anything! 18:20:13.038 DRIVER Send queue: (5 messages) · [REQ] RequestNodeInfo [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] 18:20:13.071 CNTRLR [Node 003] BatteryCC: doing a complete interview... 18:20:13.073 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 120 └─[BatteryCCGet] 18:20:13.074 SERIAL » 0x010900130302800225783b (11 bytes) 18:20:13.072 CNTRLR » [Node 003] querying battery status... 18:20:13.078 SERIAL « [ACK] (0x06) 18:20:13.078 DRIVER ACK received from controller for current transaction 18:20:13.079 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:13.084 SERIAL « 0x01 (1 bytes) 18:20:13.085 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:13.087 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:20:13.086 SERIAL « 0x04011301e8 (5 bytes) 18:20:13.086 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:20:13.087 SERIAL » [ACK] (0x06) 18:20:13.088 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:13.100 SERIAL « 0x01 (1 bytes) 18:20:13.101 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:13.103 DRIVER « [REQ] [SendData] [confirmation] callbackId: 120 transmitStatus: OK 18:20:13.102 SERIAL « 0x0700137800000291 (8 bytes) 18:20:13.102 SERIAL Buffer := 0x010700137800000291 (9 bytes) 18:20:13.103 SERIAL » [ACK] (0x06) 18:20:13.104 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:13.104 DRIVER ACK received from node for current transaction. RTT = 31.08 ms 18:20:13.111 SERIAL « 0x01 (1 bytes) 18:20:13.112 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:13.113 SERIAL « 0x09000400030380033342 (10 bytes) 18:20:13.115 CNTRLR [Node 003] [~] [Battery] level: 51 => 51 [Endpoint 0] 18:20:13.118 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[BatteryCCReport] payload: 0x33 18:20:13.116 CNTRLR [Node 003] [~] [Battery] isLow: false => false [Endpoint 0] 18:20:13.120 CNTRLR « [Node 003] received response for battery information: level: 51 18:20:13.120 CNTRLR [Node 003] [+] [Battery] interviewComplete: true [Endpoint 0] [internal] 18:20:13.121 CNTRLR [Node 003] ThermostatSetpointCC: doing a complete interview... 18:20:13.121 CNTRLR » [Node 003] querying current value of setpoint Heating... 18:20:13.118 DRIVER ACK already received, resolving transaction 18:20:13.119 DRIVER resuming send queue 18:20:13.123 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 121 └─[ThermostatSetpointCCGet] payload: 0x01 18:20:13.124 DRIVER workOffSendQueue > skipping because a transaction is pending 18:20:13.113 SERIAL Buffer := 0x0109000400030380033342 (11 bytes) 18:20:13.117 SERIAL » [ACK] (0x06) 18:20:13.119 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:13.123 SERIAL » 0x010a001303034302012579fa (12 bytes) 18:20:13.128 SERIAL « [ACK] (0x06) 18:20:13.129 DRIVER ACK received from controller for current transaction 18:20:13.129 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:13.135 SERIAL « 0x01 (1 bytes) 18:20:13.136 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:13.141 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:20:13.138 SERIAL « 0x04011301e8 (5 bytes) 18:20:13.138 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:20:13.140 SERIAL » [ACK] (0x06) 18:20:13.142 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:13.151 SERIAL « 0x01 (1 bytes) 18:20:13.154 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:13.156 DRIVER « [REQ] [SendData] [confirmation] callbackId: 121 transmitStatus: OK 18:20:13.155 SERIAL « 0x0700137900000391 (8 bytes) 18:20:13.156 SERIAL Buffer := 0x010700137900000391 (9 bytes) 18:20:13.156 SERIAL » [ACK] (0x06) 18:20:13.158 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:13.157 DRIVER ACK received from node for current transaction. RTT = 34.26 ms 18:20:13.163 SERIAL « 0x01 (1 bytes) 18:20:13.164 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:13.166 CNTRLR [Node 003] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:20:13.169 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[ThermostatSetpointCCReport] payload: 0x01420708 18:20:13.165 SERIAL « 0x0c0004000306430301420708fe (13 bytes) 18:20:13.165 SERIAL Buffer := 0x010c0004000306430301420708fe (14 bytes) 18:20:13.168 SERIAL » [ACK] (0x06) 18:20:13.171 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:13.173 SERIAL » 0x010a00130303430202257afa (12 bytes) 18:20:13.171 CNTRLR « [Node 003] received current value of setpoint Heating: 18 °C 18:20:13.171 CNTRLR » [Node 003] querying current value of setpoint Cooling... 18:20:13.169 DRIVER ACK already received, resolving transaction 18:20:13.170 DRIVER resuming send queue 18:20:13.173 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 122 └─[ThermostatSetpointCCGet] payload: 0x02 18:20:13.174 DRIVER workOffSendQueue > skipping because a transaction is pending 18:20:13.178 SERIAL « [ACK] (0x06) 18:20:13.178 DRIVER ACK received from controller for current transaction 18:20:13.179 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:13.184 SERIAL « 0x01 (1 bytes) 18:20:13.185 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:13.186 SERIAL « 0x04011301e8 (5 bytes) 18:20:13.188 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:20:13.187 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:20:13.187 SERIAL » [ACK] (0x06) 18:20:13.188 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:13.201 SERIAL « 0x01 (1 bytes) 18:20:13.202 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:13.203 SERIAL « 0x0700137a00000392 (8 bytes) 18:20:13.205 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 18:20:13.204 SERIAL Buffer := 0x010700137a00000392 (9 bytes) 18:20:13.204 SERIAL » [ACK] (0x06) 18:20:13.206 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:13.205 DRIVER ACK received from node for current transaction. RTT = 32.69 ms 18:20:14.238 CNTRLR [Node 003] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:20:14.739 SERIAL » 0x010a00130303430202257afa (12 bytes) 18:20:14.738 DRIVER » [Node 003] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 122 └─[ThermostatSetpointCCGet] payload: 0x02 18:20:14.743 SERIAL « [ACK] (0x06) 18:20:14.743 DRIVER ACK received from controller for current transaction 18:20:14.744 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:14.749 SERIAL « 0x01 (1 bytes) 18:20:14.750 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:14.752 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:20:14.751 SERIAL « 0x04011301e8 (5 bytes) 18:20:14.751 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:20:14.752 SERIAL » [ACK] (0x06) 18:20:14.753 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:14.765 SERIAL « 0x01 (1 bytes) 18:20:14.766 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:14.767 SERIAL « 0x0700137a00000293 (8 bytes) 18:20:14.768 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 18:20:14.768 SERIAL Buffer := 0x010700137a00000293 (9 bytes) 18:20:14.768 SERIAL » [ACK] (0x06) 18:20:14.770 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:14.769 DRIVER ACK received from node for current transaction. RTT = 1596.45 ms 18:20:17.366 CNTRLR [Node 003] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:20:17.867 DRIVER » [Node 003] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 122 └─[ThermostatSetpointCCGet] payload: 0x02 18:20:17.868 SERIAL » 0x010a00130303430202257afa (12 bytes) 18:20:17.872 SERIAL « [ACK] (0x06) 18:20:17.873 DRIVER ACK received from controller for current transaction 18:20:17.873 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:17.879 SERIAL « 0x01 (1 bytes) 18:20:17.879 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:17.881 SERIAL « 0x04011301e8 (5 bytes) 18:20:17.882 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:20:17.882 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:20:17.882 SERIAL » [ACK] (0x06) 18:20:17.883 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:17.896 SERIAL « 0x01 (1 bytes) 18:20:17.897 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:20:17.900 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 18:20:17.898 SERIAL « 0x0700137a00000293 (8 bytes) 18:20:17.899 SERIAL Buffer := 0x010700137a00000293 (9 bytes) 18:20:17.900 SERIAL » [ACK] (0x06) 18:20:17.901 SERIAL The receive buffer is empty, waiting for the next chunk... 18:20:17.901 DRIVER ACK received from node for current transaction. RTT = 4728.28 ms 18:20:23.172 DRIVER The awake timeout for node 3 has elapsed. Assuming it is asleep. 18:20:23.173 CNTRLR [Node 003] The node is now asleep. 18:20:23.175 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:20:23.175 DRIVER Send queue: (6 messages) · [REQ] RequestNodeInfo [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] 18:21:05.804 SERIAL « 0x01 (1 bytes) 18:21:05.805 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:05.807 CNTRLR [Node 008] [+] [Battery] level: 72 [Endpoint 0] 18:21:05.806 SERIAL « 0x09000400080380034832 (10 bytes) 18:21:05.806 SERIAL Buffer := 0x0109000400080380034832 (11 bytes) 18:21:05.810 SERIAL » [ACK] (0x06) 18:21:05.811 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:05.809 CNTRLR [Node 008] [+] [Battery] isLow: false [Endpoint 0] 18:21:05.827 SERIAL « 0x01 (1 bytes) 18:21:05.828 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:05.832 CNTRLR [Node 008] [Thermostat Setpoint] setpoint[1]: metadata updated [Endpoint 0] 18:21:05.830 SERIAL « 0x0c00040008064303014201c239 (13 bytes) 18:21:05.830 SERIAL Buffer := 0x010c00040008064303014201c239 (14 bytes) 18:21:05.836 SERIAL » [ACK] (0x06) 18:21:05.837 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:05.834 CNTRLR [Node 008] [+] [Thermostat Setpoint] setpoint[1]: 4.5 [Endpoint 0] 18:21:05.850 SERIAL « 0x01 (1 bytes) 18:21:05.850 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:05.856 SERIAL « 0x0a00040008044608007fcc (11 bytes) 18:21:05.858 CNTRLR [Node 008] [+] [Climate Control Schedule] overrideType: 0 [Endpoint 0] 18:21:05.857 SERIAL Buffer := 0x010a00040008044608007fcc (12 bytes) 18:21:05.863 SERIAL » [ACK] (0x06) 18:21:05.863 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:05.860 CNTRLR [Node 008] [+] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] 18:21:05.867 SERIAL « 0x01 (1 bytes) 18:21:05.867 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:05.872 CNTRLR [Node 008] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 18:21:05.869 SERIAL « 0x0c000400080631050142079811 (13 bytes) 18:21:05.869 SERIAL Buffer := 0x010c000400080631050142079811 (14 bytes) 18:21:05.875 SERIAL » [ACK] (0x06) 18:21:05.876 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:05.874 CNTRLR [Node 008] [+] [Multilevel Sensor] Air temperature: 19.44 [Endpoint 0] 18:21:05.887 SERIAL « 0x01 (1 bytes) 18:21:05.887 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:05.890 SERIAL « 0x08000400080284077a (9 bytes) 18:21:05.897 CNTRLR « [Node 008] received wakeup notification 18:21:05.903 DRIVER » [Node 008] [REQ] [RequestNodeInfo] [P: WakeUp] payload: 0x08 18:21:05.890 SERIAL Buffer := 0x0108000400080284077a (10 bytes) 18:21:05.897 SERIAL » [ACK] (0x06) 18:21:05.900 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:05.904 SERIAL » 0x010400600893 (6 bytes) 18:21:05.898 CNTRLR [Node 008] The node is now awake. 18:21:05.922 SERIAL « [ACK] (0x06) 18:21:05.923 DRIVER ACK received from controller for current transaction 18:21:05.924 SERIAL « 0x0601 (2 bytes) 18:21:05.924 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:05.930 DRIVER « [RES] [RequestNodeInfo] [confirmation] payload: 0x01 18:21:05.929 SERIAL « 0x040160019b (5 bytes) 18:21:05.929 SERIAL Buffer := 0x01040160019b (6 bytes) 18:21:05.930 SERIAL » [ACK] (0x06) 18:21:05.931 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.055 SERIAL « 0x01 (1 bytes) 18:21:06.055 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.058 DRIVER « [Node 008] [REQ] [ApplicationUpdateRequest] [final] payload: 0x840811040804804681728f7531438684ef46818f 18:21:06.060 CNTRLR « [Node 008] node info received supported CCs: · Battery · Climate Control Schedule · Clock · Manufacturer Specific · Multi Command · Protection · Multilevel Sensor · Thermostat Setpoint · Version · Wake Up controlled CCs: · Climate Control Schedule · Clock · Multi Command 18:21:06.057 SERIAL « 0x170049840811040804804681728f7531438684ef46818f2c (24 bytes) 18:21:06.058 SERIAL Buffer := 0x01170049840811040804804681728f7531438684ef46818f2c (25 bytes) 18:21:06.058 SERIAL » [ACK] (0x06) 18:21:06.061 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.059 DRIVER ACK already received, resolving transaction 18:21:06.059 DRIVER resuming send queue 18:21:06.061 DRIVER The remaining 5 messages are for sleeping nodes, not sending anything! 18:21:06.062 DRIVER Send queue: (5 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] 18:21:06.094 CNTRLR [Node 008] Interview stage completed: NodeInfo 18:21:06.098 DRIVER » [Node 008] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 123 └─[ManufacturerSpecificCCGet] 18:21:06.099 SERIAL » 0x0109001308027204257bc7 (11 bytes) 18:21:06.097 CNTRLR [Node 008] ManufacturerSpecificCC: doing a complete interview... 18:21:06.097 CNTRLR » [Node 008] querying manufacturer information... 18:21:06.103 SERIAL « [ACK] (0x06) 18:21:06.104 DRIVER ACK received from controller for current transaction 18:21:06.104 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.109 SERIAL « 0x01 (1 bytes) 18:21:06.110 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.113 SERIAL « 0x04011301e8 (5 bytes) 18:21:06.116 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:21:06.114 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:21:06.115 SERIAL » [ACK] (0x06) 18:21:06.116 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.126 SERIAL « 0x01 (1 bytes) 18:21:06.127 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.129 DRIVER « [REQ] [SendData] [confirmation] callbackId: 123 transmitStatus: OK 18:21:06.128 SERIAL « 0x0700137b00000292 (8 bytes) 18:21:06.128 SERIAL Buffer := 0x010700137b00000292 (9 bytes) 18:21:06.129 SERIAL » [ACK] (0x06) 18:21:06.130 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.130 DRIVER ACK received from node for current transaction. RTT = 31.58 ms 18:21:06.138 SERIAL « 0x01 (1 bytes) 18:21:06.138 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.142 CNTRLR [Node 008] [+] [Manufacturer Specific] manufacturerId: 2 [Endpoint 0] 18:21:06.151 DRIVER « [Node 008] [REQ] [ApplicationCommand] [final] └─[ManufacturerSpecificCCReport] payload: 0x000200050175 18:21:06.140 SERIAL « 0x0e00040008087205000200050175f1 (15 bytes) 18:21:06.140 SERIAL Buffer := 0x010e00040008087205000200050175f1 (16 bytes) 18:21:06.150 SERIAL » [ACK] (0x06) 18:21:06.154 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.163 SERIAL » 0x0109001308028611257c21 (11 bytes) 18:21:06.145 CNTRLR [Node 008] [+] [Manufacturer Specific] productType: 5 [Endpoint 0] 18:21:06.148 CNTRLR [Node 008] [+] [Manufacturer Specific] productId: 373 [Endpoint 0] 18:21:06.154 CNTRLR « [Node 008] received response for manufacturer information: manufacturer: Danfoss (0x02) product type: 0x05 product id: 0x0175 18:21:06.156 CNTRLR [Node 008] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 18:21:06.157 CNTRLR [Node 008] VersionCC: doing a complete interview... 18:21:06.158 CNTRLR » [Node 008] querying node versions... 18:21:06.152 DRIVER ACK already received, resolving transaction 18:21:06.153 DRIVER resuming send queue 18:21:06.161 DRIVER » [Node 008] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 124 └─[VersionCCGet] 18:21:06.164 DRIVER workOffSendQueue > skipping because a transaction is pending 18:21:06.171 SERIAL « [ACK] (0x06) 18:21:06.173 DRIVER ACK received from controller for current transaction 18:21:06.174 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.177 SERIAL « 0x01 (1 bytes) 18:21:06.178 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.182 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:21:06.180 SERIAL « 0x04011301e8 (5 bytes) 18:21:06.181 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:21:06.181 SERIAL » [ACK] (0x06) 18:21:06.182 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.196 SERIAL « 0x01 (1 bytes) 18:21:06.199 DRIVER « [REQ] [SendData] [confirmation] callbackId: 124 transmitStatus: OK 18:21:06.196 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.197 SERIAL « 0x0700137c00000394 (8 bytes) 18:21:06.198 SERIAL Buffer := 0x010700137c00000394 (9 bytes) 18:21:06.198 SERIAL » [ACK] (0x06) 18:21:06.200 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.200 DRIVER ACK received from node for current transaction. RTT = 39.10 ms 18:21:06.204 SERIAL « 0x010d0004000807861206034301002a (15 bytes) 18:21:06.206 CNTRLR [Node 008] [+] [Version] libraryType: 6 [Endpoint 0] 18:21:06.213 DRIVER « [Node 008] [REQ] [ApplicationCommand] [final] └─[VersionCCReport] payload: 0x0603430100 18:21:06.205 SERIAL Buffer := 0x010d0004000807861206034301002a (15 bytes) 18:21:06.212 SERIAL » [ACK] (0x06) 18:21:06.215 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.222 SERIAL » 0x010a00130803861384257da4 (12 bytes) 18:21:06.208 CNTRLR [Node 008] [+] [Version] protocolVersion: "3.67" [Endpoint 0] 18:21:06.210 CNTRLR [Node 008] [+] [Version] firmwareVersions: 1.0 [Endpoint 0] 18:21:06.218 CNTRLR « [Node 008] received response for node versions: library type: Routing Slave (0x06) protocol version: 3.67 firmware versions: 1.0 18:21:06.219 CNTRLR » [Node 008] querying CC versions... 18:21:06.219 CNTRLR » [Node 008] querying the CC version for Wake Up (0x84)... 18:21:06.213 DRIVER ACK already received, resolving transaction 18:21:06.214 DRIVER resuming send queue 18:21:06.221 DRIVER » [Node 008] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 125 └─[VersionCCCommandClassGet] payload: 0x84 18:21:06.223 DRIVER workOffSendQueue > skipping because a transaction is pending 18:21:06.227 SERIAL « [ACK] (0x06) 18:21:06.228 DRIVER ACK received from controller for current transaction 18:21:06.228 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.234 SERIAL « 0x01 (1 bytes) 18:21:06.234 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.237 SERIAL « 0x04011301e8 (5 bytes) 18:21:06.239 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:21:06.238 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:21:06.238 SERIAL » [ACK] (0x06) 18:21:06.239 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.251 SERIAL « 0x0107 (2 bytes) 18:21:06.253 SERIAL [incomplete] Buffer := 0x0107 (2 bytes) 18:21:06.257 DRIVER « [REQ] [SendData] [confirmation] callbackId: 125 transmitStatus: OK 18:21:06.255 SERIAL « 0x00137d00000294 (7 bytes) 18:21:06.256 SERIAL Buffer := 0x010700137d00000294 (9 bytes) 18:21:06.256 SERIAL » [ACK] (0x06) 18:21:06.258 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.257 DRIVER ACK received from node for current transaction. RTT = 36.32 ms 18:21:06.261 SERIAL « 0x010a (2 bytes) 18:21:06.262 SERIAL [incomplete] Buffer := 0x010a (2 bytes) 18:21:06.264 DRIVER « [Node 008] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8402 18:21:06.266 CNTRLR [Node 008] supports CC Wake Up (0x84) in version 2 18:21:06.264 DRIVER ACK already received, resolving transaction 18:21:06.265 DRIVER resuming send queue 18:21:06.268 DRIVER » [Node 008] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 126 └─[VersionCCCommandClassGet] payload: 0x80 18:21:06.269 DRIVER workOffSendQueue > skipping because a transaction is pending 18:21:06.262 SERIAL « 0x000400080486148402e9 (10 bytes) 18:21:06.263 SERIAL Buffer := 0x010a000400080486148402e9 (12 bytes) 18:21:06.263 SERIAL » [ACK] (0x06) 18:21:06.265 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.268 SERIAL » 0x010a00130803861380257ea3 (12 bytes) 18:21:06.266 CNTRLR » [Node 008] querying the CC version for Battery (0x80)... 18:21:06.272 SERIAL « [ACK] (0x06) 18:21:06.273 DRIVER ACK received from controller for current transaction 18:21:06.273 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.279 SERIAL « 0x01 (1 bytes) 18:21:06.279 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.281 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:21:06.280 SERIAL « 0x04011301e8 (5 bytes) 18:21:06.280 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:21:06.281 SERIAL » [ACK] (0x06) 18:21:06.282 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.296 SERIAL « 0x01 (1 bytes) 18:21:06.296 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.299 SERIAL « 0x0700137e00000297 (8 bytes) 18:21:06.300 DRIVER « [REQ] [SendData] [confirmation] callbackId: 126 transmitStatus: OK 18:21:06.299 SERIAL Buffer := 0x010700137e00000297 (9 bytes) 18:21:06.300 SERIAL » [ACK] (0x06) 18:21:06.301 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.300 DRIVER ACK received from node for current transaction. RTT = 32.95 ms 18:21:06.306 SERIAL « 0x01 (1 bytes) 18:21:06.307 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.309 DRIVER « [Node 008] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8001 18:21:06.311 CNTRLR [Node 008] supports CC Battery (0x80) in version 1 18:21:06.308 SERIAL « 0x0a000400080486148001ee (11 bytes) 18:21:06.308 SERIAL Buffer := 0x010a000400080486148001ee (12 bytes) 18:21:06.309 SERIAL » [ACK] (0x06) 18:21:06.311 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.315 SERIAL » 0x010a00130803861372257f50 (12 bytes) 18:21:06.310 DRIVER ACK already received, resolving transaction 18:21:06.310 DRIVER resuming send queue 18:21:06.314 DRIVER » [Node 008] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 127 └─[VersionCCCommandClassGet] payload: 0x72 18:21:06.315 DRIVER workOffSendQueue > skipping because a transaction is pending 18:21:06.312 CNTRLR [Node 008] skipping query for Climate Control Schedule (0x46) because max im plemented version is 1 18:21:06.312 CNTRLR [Node 008] skipping query for Clock (0x81) because max implemented version i s 0 18:21:06.312 CNTRLR » [Node 008] querying the CC version for Manufacturer Specific (0x72)... 18:21:06.341 SERIAL « [ACK] (0x06) 18:21:06.342 DRIVER ACK received from controller for current transaction 18:21:06.342 SERIAL « 0x060104011301e8 (7 bytes) 18:21:06.342 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:21:06.343 SERIAL » [ACK] (0x06) 18:21:06.344 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.343 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:21:06.353 SERIAL « 0x01 (1 bytes) 18:21:06.354 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.357 DRIVER « [REQ] [SendData] [confirmation] callbackId: 127 transmitStatus: OK 18:21:06.356 SERIAL « 0x0700137f00000397 (8 bytes) 18:21:06.356 SERIAL Buffer := 0x010700137f00000397 (9 bytes) 18:21:06.356 SERIAL » [ACK] (0x06) 18:21:06.358 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.357 DRIVER ACK received from node for current transaction. RTT = 43.35 ms 18:21:06.361 SERIAL « 0x01 (1 bytes) 18:21:06.361 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.364 DRIVER « [Node 008] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x7201 18:21:06.366 CNTRLR [Node 008] supports CC Manufacturer Specific (0x72) in version 1 18:21:06.362 SERIAL « 0x0a0004000804861472011c (11 bytes) 18:21:06.362 SERIAL Buffer := 0x010a0004000804861472011c (12 bytes) 18:21:06.363 SERIAL » [ACK] (0x06) 18:21:06.365 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.364 DRIVER ACK already received, resolving transaction 18:21:06.365 DRIVER resuming send queue 18:21:06.369 DRIVER » [Node 008] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 128 └─[VersionCCCommandClassGet] payload: 0x31 18:21:06.370 DRIVER workOffSendQueue > skipping because a transaction is pending 18:21:06.366 CNTRLR [Node 008] skipping query for Multi Command (0x8f) because max implemented v ersion is 1 18:21:06.367 CNTRLR [Node 008] skipping query for Protection (0x75) because max implemented vers ion is 0 18:21:06.367 CNTRLR » [Node 008] querying the CC version for Multilevel Sensor (0x31)... 18:21:06.369 SERIAL » 0x010a001308038613312580ec (12 bytes) 18:21:06.374 SERIAL « [ACK] (0x06) 18:21:06.374 DRIVER ACK received from controller for current transaction 18:21:06.375 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.381 SERIAL « 0x01 (1 bytes) 18:21:06.381 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.383 SERIAL « 0x04011301e8 (5 bytes) 18:21:06.384 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:21:06.383 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:21:06.383 SERIAL » [ACK] (0x06) 18:21:06.384 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.397 SERIAL « 0x01 (1 bytes) 18:21:06.398 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.399 SERIAL « 0x0700138000000269 (8 bytes) 18:21:06.400 DRIVER « [REQ] [SendData] [confirmation] callbackId: 128 transmitStatus: OK 18:21:06.399 SERIAL Buffer := 0x010700138000000269 (9 bytes) 18:21:06.400 SERIAL » [ACK] (0x06) 18:21:06.401 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.401 DRIVER ACK received from node for current transaction. RTT = 32.34 ms 18:21:06.408 SERIAL « 0x01 (1 bytes) 18:21:06.408 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.412 DRIVER « [Node 008] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x3106 18:21:06.414 CNTRLR [Node 008] supports CC Multilevel Sensor (0x31) in version 6 18:21:06.411 SERIAL « 0x0a00040008048614310658 (11 bytes) 18:21:06.411 SERIAL Buffer := 0x010a00040008048614310658 (12 bytes) 18:21:06.412 SERIAL » [ACK] (0x06) 18:21:06.414 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.413 DRIVER ACK already received, resolving transaction 18:21:06.413 DRIVER resuming send queue 18:21:06.417 DRIVER » [Node 008] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 129 └─[VersionCCCommandClassGet] payload: 0x43 18:21:06.418 DRIVER workOffSendQueue > skipping because a transaction is pending 18:21:06.415 CNTRLR » [Node 008] querying the CC version for Thermostat Setpoint (0x43)... 18:21:06.417 SERIAL » 0x010a0013080386134325819f (12 bytes) 18:21:06.421 SERIAL « [ACK] (0x06) 18:21:06.422 DRIVER ACK received from controller for current transaction 18:21:06.422 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.428 SERIAL « 0x01 (1 bytes) 18:21:06.428 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.430 SERIAL « 0x04011301e8 (5 bytes) 18:21:06.432 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:21:06.431 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:21:06.431 SERIAL » [ACK] (0x06) 18:21:06.432 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.445 SERIAL « 0x01 (1 bytes) 18:21:06.445 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.449 SERIAL « 0x0700138100000268 (8 bytes) 18:21:06.451 DRIVER « [REQ] [SendData] [confirmation] callbackId: 129 transmitStatus: OK 18:21:06.450 SERIAL Buffer := 0x010700138100000268 (9 bytes) 18:21:06.450 SERIAL » [ACK] (0x06) 18:21:06.452 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.451 DRIVER ACK received from node for current transaction. RTT = 34.64 ms 18:21:06.456 SERIAL « 0x01 (1 bytes) 18:21:06.456 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.458 DRIVER « [Node 008] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x4302 18:21:06.461 CNTRLR [Node 008] supports CC Thermostat Setpoint (0x43) in version 2 18:21:06.457 SERIAL « 0x0a0004000804861443022e (11 bytes) 18:21:06.457 SERIAL Buffer := 0x010a0004000804861443022e (12 bytes) 18:21:06.458 SERIAL » [ACK] (0x06) 18:21:06.461 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.464 SERIAL » 0x010a00130803861386258259 (12 bytes) 18:21:06.460 DRIVER ACK already received, resolving transaction 18:21:06.461 DRIVER resuming send queue 18:21:06.464 DRIVER » [Node 008] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 130 └─[VersionCCCommandClassGet] payload: 0x86 18:21:06.464 DRIVER workOffSendQueue > skipping because a transaction is pending 18:21:06.462 CNTRLR » [Node 008] querying the CC version for Version (0x86)... 18:21:06.468 SERIAL « [ACK] (0x06) 18:21:06.468 DRIVER ACK received from controller for current transaction 18:21:06.469 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.475 SERIAL « 0x01 (1 bytes) 18:21:06.475 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.476 SERIAL « 0x04011301e8 (5 bytes) 18:21:06.478 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:21:06.477 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:21:06.477 SERIAL » [ACK] (0x06) 18:21:06.478 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.491 SERIAL « 0x01 (1 bytes) 18:21:06.492 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.494 SERIAL « 0x070013820000036a (8 bytes) 18:21:06.495 DRIVER « [REQ] [SendData] [confirmation] callbackId: 130 transmitStatus: OK 18:21:06.494 SERIAL Buffer := 0x01070013820000036a (9 bytes) 18:21:06.495 SERIAL » [ACK] (0x06) 18:21:06.496 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.496 DRIVER ACK received from node for current transaction. RTT = 32.12 ms 18:21:06.502 SERIAL « 0x01 (1 bytes) 18:21:06.502 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.504 SERIAL « 0x0a000400080486148601e8 (11 bytes) 18:21:06.506 DRIVER « [Node 008] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8601 18:21:06.508 CNTRLR [Node 008] supports CC Version (0x86) in version 1 18:21:06.505 SERIAL Buffer := 0x010a000400080486148601e8 (12 bytes) 18:21:06.505 SERIAL » [ACK] (0x06) 18:21:06.507 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.506 DRIVER ACK already received, resolving transaction 18:21:06.507 DRIVER resuming send queue 18:21:06.510 DRIVER The remaining 5 messages are for sleeping nodes, not sending anything! 18:21:06.510 DRIVER Send queue: (5 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] 18:21:06.508 CNTRLR [Node 008] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 18:21:06.509 CNTRLR [Node 008] trying to load device config 18:21:06.514 CNTRLR [Node 008] device config loaded 18:21:06.545 CNTRLR [Node 008] WakeUpCC: doing a complete interview... 18:21:06.547 DRIVER » [Node 008] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 131 └─[WakeUpCCIntervalCapabilitiesGet] 18:21:06.547 SERIAL » 0x01090013080284092583c4 (11 bytes) 18:21:06.545 CNTRLR » [Node 008] retrieving wakeup capabilities from the device... 18:21:06.551 SERIAL « [ACK] (0x06) 18:21:06.552 DRIVER ACK received from controller for current transaction 18:21:06.552 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.558 SERIAL « 0x01 (1 bytes) 18:21:06.559 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.560 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:21:06.559 SERIAL « 0x04011301e8 (5 bytes) 18:21:06.560 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:21:06.560 SERIAL » [ACK] (0x06) 18:21:06.561 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.575 SERIAL « 0x01 (1 bytes) 18:21:06.576 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.578 DRIVER « [REQ] [SendData] [confirmation] callbackId: 131 transmitStatus: OK 18:21:06.576 SERIAL « 0x070013830000026a (8 bytes) 18:21:06.577 SERIAL Buffer := 0x01070013830000026a (9 bytes) 18:21:06.577 SERIAL » [ACK] (0x06) 18:21:06.579 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.578 DRIVER ACK received from node for current transaction. RTT = 31.75 ms 18:21:06.587 SERIAL « 0x01 (1 bytes) 18:21:06.588 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.590 CNTRLR [Node 008] [Wake Up] wakeUpInterval: metadata updated [Endpoint 0] 18:21:06.592 DRIVER « [Node 008] [REQ] [ApplicationCommand] [final] └─[WakeUpCCIntervalCapabilitiesReport] payload: 0x00003c00070800012c00003c 18:21:06.589 SERIAL « 0x14000400080e840a00003c00070800012c00003c45 (21 bytes) 18:21:06.589 SERIAL Buffer := 0x0114000400080e840a00003c00070800012c00003c45 (22 bytes) 18:21:06.592 SERIAL » [ACK] (0x06) 18:21:06.594 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.594 CNTRLR « [Node 008] received wakeup capabilities: default wakeup interval: 300 seconds minimum wakeup interval: 60 seconds maximum wakeup interval: 1800 seconds wakeup interval steps: 60 seconds 18:21:06.595 CNTRLR » [Node 008] retrieving wakeup interval from the device... 18:21:06.593 DRIVER ACK already received, resolving transaction 18:21:06.594 DRIVER resuming send queue 18:21:06.597 DRIVER » [Node 008] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 132 └─[WakeUpCCIntervalGet] 18:21:06.598 DRIVER workOffSendQueue > skipping because a transaction is pending 18:21:06.597 SERIAL » 0x01090013080284052584cf (11 bytes) 18:21:06.602 SERIAL « [ACK] (0x06) 18:21:06.602 DRIVER ACK received from controller for current transaction 18:21:06.603 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.611 SERIAL « 0x0104011301e8 (6 bytes) 18:21:06.613 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:21:06.612 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:21:06.612 SERIAL » [ACK] (0x06) 18:21:06.614 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.625 SERIAL « 0x0107 (2 bytes) 18:21:06.626 SERIAL [incomplete] Buffer := 0x0107 (2 bytes) 18:21:06.629 DRIVER « [REQ] [SendData] [confirmation] callbackId: 132 transmitStatus: OK 18:21:06.627 SERIAL « 0x0013840000026d (7 bytes) 18:21:06.627 SERIAL Buffer := 0x01070013840000026d (9 bytes) 18:21:06.628 SERIAL » [ACK] (0x06) 18:21:06.630 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.630 DRIVER ACK received from node for current transaction. RTT = 33.22 ms 18:21:06.636 SERIAL « 0x010c (2 bytes) 18:21:06.636 SERIAL [incomplete] Buffer := 0x010c (2 bytes) 18:21:06.639 CNTRLR [Node 008] [+] [Wake Up] wakeUpInterval: 300 [Endpoint 0] 18:21:06.643 DRIVER « [Node 008] [REQ] [ApplicationCommand] [final] └─[WakeUpCCIntervalReport] payload: 0x00012c01 18:21:06.638 SERIAL « 0x0004000806840600012c0157 (12 bytes) 18:21:06.638 SERIAL Buffer := 0x010c0004000806840600012c0157 (14 bytes) 18:21:06.642 SERIAL » [ACK] (0x06) 18:21:06.645 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.649 SERIAL » 0x01090013080280022585cd (11 bytes) 18:21:06.644 DRIVER ACK already received, resolving transaction 18:21:06.644 DRIVER resuming send queue 18:21:06.649 DRIVER » [Node 008] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 133 └─[BatteryCCGet] 18:21:06.650 DRIVER workOffSendQueue > skipping because a transaction is pending 18:21:06.641 CNTRLR [Node 008] [+] [Wake Up] controllerNodeId: 1 [Endpoint 0] 18:21:06.645 CNTRLR « [Node 008] received wakeup configuration: wakeup interval: 300 seconds controller node: 1 18:21:06.646 CNTRLR [Node 008] [+] [Wake Up] interviewComplete: true [Endpoint 0] [internal] 18:21:06.647 CNTRLR [Node 008] BatteryCC: doing a complete interview... 18:21:06.647 CNTRLR » [Node 008] querying battery status... 18:21:06.656 SERIAL « [ACK] (0x06) 18:21:06.657 DRIVER ACK received from controller for current transaction 18:21:06.657 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.661 SERIAL « 0x01 (1 bytes) 18:21:06.662 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.664 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:21:06.663 SERIAL « 0x04011301e8 (5 bytes) 18:21:06.664 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:21:06.664 SERIAL » [ACK] (0x06) 18:21:06.666 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.678 SERIAL « 0x01 (1 bytes) 18:21:06.678 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.680 DRIVER « [REQ] [SendData] [confirmation] callbackId: 133 transmitStatus: OK 18:21:06.679 SERIAL « 0x070013850000026c (8 bytes) 18:21:06.680 SERIAL Buffer := 0x01070013850000026c (9 bytes) 18:21:06.680 SERIAL » [ACK] (0x06) 18:21:06.682 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.681 DRIVER ACK received from node for current transaction. RTT = 32.45 ms 18:21:06.689 SERIAL « 0x01 (1 bytes) 18:21:06.690 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.693 CNTRLR [Node 008] [~] [Battery] level: 72 => 72 [Endpoint 0] 18:21:06.697 DRIVER « [Node 008] [REQ] [ApplicationCommand] [final] └─[BatteryCCReport] payload: 0x48 18:21:06.695 CNTRLR [Node 008] [~] [Battery] isLow: false => false [Endpoint 0] 18:21:06.700 CNTRLR « [Node 008] received response for battery information: level: 72 18:21:06.705 CNTRLR [Node 008] [+] [Battery] interviewComplete: true [Endpoint 0] [internal] 18:21:06.691 SERIAL « 0x09000400080380034832 (10 bytes) 18:21:06.691 SERIAL Buffer := 0x0109000400080380034832 (11 bytes) 18:21:06.696 SERIAL » [ACK] (0x06) 18:21:06.700 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.699 DRIVER ACK already received, resolving transaction 18:21:06.700 DRIVER resuming send queue 18:21:06.707 DRIVER The remaining 5 messages are for sleeping nodes, not sending anything! 18:21:06.708 DRIVER Send queue: (5 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] 18:21:06.743 CNTRLR [Node 008] MultilevelSensorCC: doing a complete interview... 18:21:06.747 DRIVER » [Node 008] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 134 └─[MultilevelSensorCCGetSupportedSensor] 18:21:06.747 SERIAL » 0x010900130802310125867c (11 bytes) 18:21:06.744 CNTRLR » [Node 008] retrieving supported sensor types... 18:21:06.752 SERIAL « [ACK] (0x06) 18:21:06.753 DRIVER ACK received from controller for current transaction 18:21:06.753 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.758 SERIAL « 0x01 (1 bytes) 18:21:06.758 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.760 SERIAL « 0x04011301e8 (5 bytes) 18:21:06.761 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:21:06.760 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:21:06.760 SERIAL » [ACK] (0x06) 18:21:06.761 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.774 SERIAL « 0x01 (1 bytes) 18:21:06.774 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.776 SERIAL « 0x070013860000026f (8 bytes) 18:21:06.778 DRIVER « [REQ] [SendData] [confirmation] callbackId: 134 transmitStatus: OK 18:21:06.777 SERIAL Buffer := 0x01070013860000026f (9 bytes) 18:21:06.777 SERIAL » [ACK] (0x06) 18:21:06.779 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.778 DRIVER ACK received from node for current transaction. RTT = 31.81 ms 18:21:06.784 SERIAL « 0x01 (1 bytes) 18:21:06.784 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.787 SERIAL « 0x090004000803310201cb (10 bytes) 18:21:06.789 CNTRLR [Node 008] [+] [Multilevel Sensor] supportedSensorType [Endpoint 0] [internal] s: 1 18:21:06.790 DRIVER « [Node 008] [REQ] [ApplicationCommand] [final] └─[MultilevelSensorCCSupportedSensorReport] payload: 0x01 18:21:06.787 SERIAL Buffer := 0x01090004000803310201cb (11 bytes) 18:21:06.790 SERIAL » [ACK] (0x06) 18:21:06.792 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.796 SERIAL » 0x010a0013080331030125877c (12 bytes) 18:21:06.792 CNTRLR « [Node 008] received supported sensor types: · Air temperature 18:21:06.793 CNTRLR » [Node 008] querying supported scales for Air temperature sensor 18:21:06.791 DRIVER ACK already received, resolving transaction 18:21:06.791 DRIVER resuming send queue 18:21:06.796 DRIVER » [Node 008] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 135 └─[MultilevelSensorCCGetSupportedScale] payload: 0x01 18:21:06.796 DRIVER workOffSendQueue > skipping because a transaction is pending 18:21:06.801 SERIAL « [ACK] (0x06) 18:21:06.801 DRIVER ACK received from controller for current transaction 18:21:06.802 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.807 SERIAL « 0x01 (1 bytes) 18:21:06.808 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.810 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:21:06.809 SERIAL « 0x04011301e8 (5 bytes) 18:21:06.809 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:21:06.809 SERIAL » [ACK] (0x06) 18:21:06.810 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.824 SERIAL « 0x01 (1 bytes) 18:21:06.824 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.826 DRIVER « [REQ] [SendData] [confirmation] callbackId: 135 transmitStatus: OK 18:21:06.826 SERIAL « 0x070013870000026e (8 bytes) 18:21:06.826 SERIAL Buffer := 0x01070013870000026e (9 bytes) 18:21:06.826 SERIAL » [ACK] (0x06) 18:21:06.828 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.827 DRIVER ACK received from node for current transaction. RTT = 32.29 ms 18:21:06.835 SERIAL « 0x01 (1 bytes) 18:21:06.835 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.837 SERIAL « 0x0a000400080431060100cb (11 bytes) 18:21:06.841 CNTRLR [Node 008] [+] [Multilevel Sensor] supportedScales[1]: [Endpoint 0] [internal] 18:21:06.842 DRIVER « [Node 008] [REQ] [ApplicationCommand] [final] └─[MultilevelSensorCCSupportedScaleReport] payload: 0x0100 18:21:06.845 CNTRLR « [Node 008] received supported scales: 18:21:06.845 CNTRLR » [Node 008] querying current sensor reading... 18:21:06.839 SERIAL Buffer := 0x010a000400080431060100cb (12 bytes) 18:21:06.842 SERIAL » [ACK] (0x06) 18:21:06.844 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.848 SERIAL » 0x0109001308023104258877 (11 bytes) 18:21:06.843 DRIVER ACK already received, resolving transaction 18:21:06.843 DRIVER resuming send queue 18:21:06.848 DRIVER » [Node 008] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 136 └─[MultilevelSensorCCGet] 18:21:06.849 DRIVER workOffSendQueue > skipping because a transaction is pending 18:21:06.853 SERIAL « [ACK] (0x06) 18:21:06.853 DRIVER ACK received from controller for current transaction 18:21:06.854 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.864 SERIAL « 0x01 (1 bytes) 18:21:06.865 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.868 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:21:06.866 SERIAL « 0x04011301e8 (5 bytes) 18:21:06.867 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:21:06.867 SERIAL » [ACK] (0x06) 18:21:06.869 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.877 SERIAL « 0x01 (1 bytes) 18:21:06.878 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.881 DRIVER « [REQ] [SendData] [confirmation] callbackId: 136 transmitStatus: OK 18:21:06.879 SERIAL « 0x0700138800000261 (8 bytes) 18:21:06.879 SERIAL Buffer := 0x010700138800000261 (9 bytes) 18:21:06.880 SERIAL » [ACK] (0x06) 18:21:06.882 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.881 DRIVER ACK received from node for current transaction. RTT = 33.77 ms 18:21:06.888 SERIAL « 0x01 (1 bytes) 18:21:06.888 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.890 CNTRLR [Node 008] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 18:21:06.895 DRIVER « [Node 008] [REQ] [ApplicationCommand] [final] └─[MultilevelSensorCCReport] payload: 0x01420798 18:21:06.889 SERIAL « 0x0c000400080631050142079811 (13 bytes) 18:21:06.889 SERIAL Buffer := 0x010c000400080631050142079811 (14 bytes) 18:21:06.894 SERIAL » [ACK] (0x06) 18:21:06.896 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.892 CNTRLR [Node 008] [~] [Multilevel Sensor] Air temperature: 19.44 => 19.4 [Endpoint 0] 4 18:21:06.897 CNTRLR « [Node 008] received current sensor reading: 19.44 18:21:06.898 CNTRLR [Node 008] [+] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true 18:21:06.895 DRIVER ACK already received, resolving transaction 18:21:06.896 DRIVER resuming send queue 18:21:06.899 DRIVER The remaining 5 messages are for sleeping nodes, not sending anything! 18:21:06.900 DRIVER Send queue: (5 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] 18:21:06.925 CNTRLR [Node 008] ThermostatSetpointCC: doing a complete interview... 18:21:06.928 DRIVER » [Node 008] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 137 └─[ThermostatSetpointCCGet] payload: 0x01 18:21:06.928 SERIAL » 0x010a00130803430201258901 (12 bytes) 18:21:06.926 CNTRLR » [Node 008] querying current value of setpoint Heating... 18:21:06.932 SERIAL « [ACK] (0x06) 18:21:06.933 DRIVER ACK received from controller for current transaction 18:21:06.933 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.938 SERIAL « 0x01 (1 bytes) 18:21:06.938 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.940 SERIAL « 0x04011301e8 (5 bytes) 18:21:06.941 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:21:06.940 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:21:06.941 SERIAL » [ACK] (0x06) 18:21:06.941 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.955 SERIAL « 0x01 (1 bytes) 18:21:06.955 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.957 DRIVER « [REQ] [SendData] [confirmation] callbackId: 137 transmitStatus: OK 18:21:06.956 SERIAL « 0x0700138900000260 (8 bytes) 18:21:06.956 SERIAL Buffer := 0x010700138900000260 (9 bytes) 18:21:06.957 SERIAL » [ACK] (0x06) 18:21:06.959 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.958 DRIVER ACK received from node for current transaction. RTT = 30.67 ms 18:21:06.967 SERIAL « 0x01 (1 bytes) 18:21:06.968 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.971 CNTRLR [Node 008] [~] [Thermostat Setpoint] setpoint[1]: 4.5 => 4.5 [Endpoint 0] 18:21:06.973 DRIVER « [Node 008] [REQ] [ApplicationCommand] [final] └─[ThermostatSetpointCCReport] payload: 0x014201c2 18:21:06.969 SERIAL « 0x0c00040008064303014201c239 (13 bytes) 18:21:06.970 SERIAL Buffer := 0x010c00040008064303014201c239 (14 bytes) 18:21:06.972 SERIAL » [ACK] (0x06) 18:21:06.974 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.976 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:21:06.975 CNTRLR « [Node 008] received current value of setpoint Heating: 4.5 °C 18:21:06.975 CNTRLR » [Node 008] querying current value of setpoint Cooling... 18:21:06.973 DRIVER ACK already received, resolving transaction 18:21:06.974 DRIVER resuming send queue 18:21:06.976 DRIVER » [Node 008] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:21:06.977 DRIVER workOffSendQueue > skipping because a transaction is pending 18:21:06.981 SERIAL « [ACK] (0x06) 18:21:06.982 DRIVER ACK received from controller for current transaction 18:21:06.982 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:06.988 SERIAL « 0x01 (1 bytes) 18:21:06.988 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:06.991 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:21:06.990 SERIAL « 0x04011301e8 (5 bytes) 18:21:06.990 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:21:06.990 SERIAL » [ACK] (0x06) 18:21:06.992 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:07.006 SERIAL « 0x01 (1 bytes) 18:21:07.006 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:07.008 SERIAL « 0x0700138a00000263 (8 bytes) 18:21:07.009 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:21:07.008 SERIAL Buffer := 0x010700138a00000263 (9 bytes) 18:21:07.009 SERIAL » [ACK] (0x06) 18:21:07.011 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:07.010 DRIVER ACK received from node for current transaction. RTT = 33.99 ms 18:21:08.044 CNTRLR [Node 008] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:21:08.544 DRIVER » [Node 008] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:21:08.545 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:21:08.549 SERIAL « [ACK] (0x06) 18:21:08.550 DRIVER ACK received from controller for current transaction 18:21:08.550 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:08.557 SERIAL « 0x01 (1 bytes) 18:21:08.557 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:08.561 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:21:08.560 SERIAL « 0x04011301e8 (5 bytes) 18:21:08.560 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:21:08.560 SERIAL » [ACK] (0x06) 18:21:08.564 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:08.572 SERIAL « 0x01 (1 bytes) 18:21:08.572 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:08.574 SERIAL « 0x0700138a00000362 (8 bytes) 18:21:08.575 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:21:08.574 SERIAL Buffer := 0x010700138a00000362 (9 bytes) 18:21:08.575 SERIAL » [ACK] (0x06) 18:21:08.576 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:08.576 DRIVER ACK received from node for current transaction. RTT = 1599.90 ms 18:21:11.176 CNTRLR [Node 008] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:21:11.678 DRIVER » [Node 008] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:21:11.679 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:21:11.683 SERIAL « [ACK] (0x06) 18:21:11.684 DRIVER ACK received from controller for current transaction 18:21:11.684 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:11.690 SERIAL « 0x01 (1 bytes) 18:21:11.690 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:11.693 SERIAL « 0x04011301e8 (5 bytes) 18:21:11.695 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:21:11.694 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:21:11.694 SERIAL » [ACK] (0x06) 18:21:11.696 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:11.706 SERIAL « 0x01 (1 bytes) 18:21:11.707 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:21:11.708 SERIAL « 0x0700138a00000263 (8 bytes) 18:21:11.710 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:21:11.708 SERIAL Buffer := 0x010700138a00000263 (9 bytes) 18:21:11.708 SERIAL » [ACK] (0x06) 18:21:11.711 SERIAL The receive buffer is empty, waiting for the next chunk... 18:21:11.710 DRIVER ACK received from node for current transaction. RTT = 4734.28 ms 18:21:16.974 DRIVER The awake timeout for node 8 has elapsed. Assuming it is asleep. 18:21:16.975 CNTRLR [Node 008] The node is now asleep. 18:21:16.976 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:21:16.977 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:22:13.449 SERIAL « 0x01 (1 bytes) 18:22:13.449 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:22:13.451 SERIAL « 0x09000400020380035020 (10 bytes) 18:22:13.452 CNTRLR [Node 002] [~] [Battery] level: 80 => 80 [Endpoint 0] 18:22:13.454 CNTRLR [Node 002] [~] [Battery] isLow: false => false [Endpoint 0] 18:22:13.451 SERIAL Buffer := 0x0109000400020380035020 (11 bytes) 18:22:13.455 SERIAL » [ACK] (0x06) 18:22:13.456 SERIAL The receive buffer is empty, waiting for the next chunk... 18:22:13.471 SERIAL « 0x01 (1 bytes) 18:22:13.471 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:22:13.473 SERIAL « 0x0c0004000206430301420708ff (13 bytes) 18:22:13.476 CNTRLR [Node 002] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:22:13.474 SERIAL Buffer := 0x010c0004000206430301420708ff (14 bytes) 18:22:13.478 SERIAL » [ACK] (0x06) 18:22:13.479 SERIAL The receive buffer is empty, waiting for the next chunk... 18:22:13.491 SERIAL « 0x01 (1 bytes) 18:22:13.492 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:22:13.494 CNTRLR [Node 002] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:22:13.493 SERIAL « 0x0a00040002044608007fc6 (11 bytes) 18:22:13.493 SERIAL Buffer := 0x010a00040002044608007fc6 (12 bytes) 18:22:13.497 SERIAL » [ACK] (0x06) 18:22:13.498 SERIAL The receive buffer is empty, waiting for the next chunk... 18:22:13.496 CNTRLR [Node 002] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:22:13.512 SERIAL « 0x01 (1 bytes) 18:22:13.513 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:22:13.518 CNTRLR « [Node 002] received wakeup notification 18:22:13.516 SERIAL « 0x080004000202840770 (9 bytes) 18:22:13.516 SERIAL Buffer := 0x01080004000202840770 (10 bytes) 18:22:13.517 SERIAL » [ACK] (0x06) 18:22:13.521 SERIAL The receive buffer is empty, waiting for the next chunk... 18:22:13.522 DRIVER » [Node 002] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:22:13.519 CNTRLR [Node 002] The node is now awake. 18:22:13.523 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:22:13.527 SERIAL « [ACK] (0x06) 18:22:13.528 DRIVER Unexpected ACK received 18:22:13.528 SERIAL The receive buffer is empty, waiting for the next chunk... 18:22:13.534 SERIAL « 0x01 (1 bytes) 18:22:13.534 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:22:13.537 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:22:13.536 SERIAL « 0x04011301e8 (5 bytes) 18:22:13.536 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:22:13.536 SERIAL » [ACK] (0x06) 18:22:13.537 SERIAL The receive buffer is empty, waiting for the next chunk... 18:22:13.551 SERIAL « 0x01 (1 bytes) 18:22:13.551 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:22:13.553 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:22:13.552 SERIAL « 0x0700134a000002a3 (8 bytes) 18:22:13.552 SERIAL Buffer := 0x010700134a000002a3 (9 bytes) 18:22:13.553 SERIAL » [ACK] (0x06) 18:22:13.554 SERIAL The receive buffer is empty, waiting for the next chunk... 18:22:13.554 DRIVER ACK received from node for current transaction. RTT = 31.61 ms 18:22:14.586 CNTRLR [Node 002] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:22:15.087 DRIVER » [Node 002] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:22:15.088 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:22:15.092 SERIAL « [ACK] (0x06) 18:22:15.093 DRIVER ACK received from controller for current transaction 18:22:15.093 SERIAL The receive buffer is empty, waiting for the next chunk... 18:22:15.099 SERIAL « 0x01 (1 bytes) 18:22:15.099 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:22:15.101 SERIAL « 0x04011301e8 (5 bytes) 18:22:15.102 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:22:15.101 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:22:15.101 SERIAL » [ACK] (0x06) 18:22:15.102 SERIAL The receive buffer is empty, waiting for the next chunk... 18:22:15.116 SERIAL « 0x01 (1 bytes) 18:22:15.116 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:22:15.118 SERIAL « 0x0700134a000002a3 (8 bytes) 18:22:15.119 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:22:15.118 SERIAL Buffer := 0x010700134a000002a3 (9 bytes) 18:22:15.119 SERIAL » [ACK] (0x06) 18:22:15.120 SERIAL The receive buffer is empty, waiting for the next chunk... 18:22:15.120 DRIVER ACK received from node for current transaction. RTT = 1597.82 ms 18:22:17.718 CNTRLR [Node 002] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:22:18.219 DRIVER » [Node 002] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:22:18.220 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:22:18.223 SERIAL « [ACK] (0x06) 18:22:18.224 DRIVER ACK received from controller for current transaction 18:22:18.224 SERIAL The receive buffer is empty, waiting for the next chunk... 18:22:18.230 SERIAL « 0x01 (1 bytes) 18:22:18.230 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:22:18.235 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:22:18.233 SERIAL « 0x04011301e8 (5 bytes) 18:22:18.234 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:22:18.234 SERIAL » [ACK] (0x06) 18:22:18.236 SERIAL The receive buffer is empty, waiting for the next chunk... 18:22:18.246 SERIAL « 0x01 (1 bytes) 18:22:18.247 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:22:18.249 SERIAL « 0x0700134a000002a3 (8 bytes) 18:22:18.250 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:22:18.249 SERIAL Buffer := 0x010700134a000002a3 (9 bytes) 18:22:18.249 SERIAL » [ACK] (0x06) 18:22:18.251 SERIAL The receive buffer is empty, waiting for the next chunk... 18:22:18.250 DRIVER ACK received from node for current transaction. RTT = 4728.28 ms 18:22:23.520 DRIVER The awake timeout for node 2 has elapsed. Assuming it is asleep. 18:22:23.521 CNTRLR [Node 002] The node is now asleep. 18:22:23.524 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:22:23.525 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:23:34.032 SERIAL « 0x01 (1 bytes) 18:23:34.033 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:23:34.034 SERIAL « 0x09000400050380033a4d (10 bytes) 18:23:34.036 CNTRLR [Node 005] [~] [Battery] level: 58 => 58 [Endpoint 0] 18:23:34.034 SERIAL Buffer := 0x0109000400050380033a4d (11 bytes) 18:23:34.039 SERIAL » [ACK] (0x06) 18:23:34.041 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:34.038 CNTRLR [Node 005] [~] [Battery] isLow: false => false [Endpoint 0] 18:23:34.055 SERIAL « 0x01 (1 bytes) 18:23:34.056 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:23:34.059 CNTRLR [Node 005] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:23:34.058 SERIAL « 0x0c0004000506430301420708f8 (13 bytes) 18:23:34.058 SERIAL Buffer := 0x010c0004000506430301420708f8 (14 bytes) 18:23:34.060 SERIAL » [ACK] (0x06) 18:23:34.061 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:34.073 SERIAL « 0x01 (1 bytes) 18:23:34.074 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:23:34.075 SERIAL « 0x0a00040005044608007fc1 (11 bytes) 18:23:34.077 CNTRLR [Node 005] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:23:34.076 SERIAL Buffer := 0x010a00040005044608007fc1 (12 bytes) 18:23:34.080 SERIAL » [ACK] (0x06) 18:23:34.081 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:34.079 CNTRLR [Node 005] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:23:34.097 SERIAL « 0x01080004000502840777 (10 bytes) 18:23:34.099 CNTRLR « [Node 005] received wakeup notification 18:23:34.103 DRIVER » [Node 005] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:23:34.098 SERIAL Buffer := 0x01080004000502840777 (10 bytes) 18:23:34.098 SERIAL » [ACK] (0x06) 18:23:34.102 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:34.104 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:23:34.100 CNTRLR [Node 005] The node is now awake. 18:23:34.112 SERIAL « [ACK] (0x06) 18:23:34.113 DRIVER Unexpected ACK received 18:23:34.113 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:34.118 SERIAL « 0x01 (1 bytes) 18:23:34.118 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:23:34.120 SERIAL « 0x04011301e8 (5 bytes) 18:23:34.122 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:23:34.121 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:23:34.121 SERIAL » [ACK] (0x06) 18:23:34.122 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:34.135 SERIAL « 0x01 (1 bytes) 18:23:34.136 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:23:34.139 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:23:34.137 SERIAL « 0x07001356000002bf (8 bytes) 18:23:34.137 SERIAL Buffer := 0x0107001356000002bf (9 bytes) 18:23:34.138 SERIAL » [ACK] (0x06) 18:23:34.140 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:34.139 DRIVER ACK received from node for current transaction. RTT = 36.58 ms 18:23:35.176 CNTRLR [Node 005] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:23:35.677 DRIVER » [Node 005] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:23:35.678 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:23:35.681 SERIAL « [ACK] (0x06) 18:23:35.682 DRIVER ACK received from controller for current transaction 18:23:35.682 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:35.687 SERIAL « 0x01 (1 bytes) 18:23:35.688 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:23:35.690 SERIAL « 0x04011301e8 (5 bytes) 18:23:35.691 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:23:35.690 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:23:35.690 SERIAL » [ACK] (0x06) 18:23:35.691 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:35.704 SERIAL « 0x01 (1 bytes) 18:23:35.705 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:23:35.707 SERIAL « 0x07001356000002bf (8 bytes) 18:23:35.709 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:23:35.707 SERIAL Buffer := 0x0107001356000002bf (9 bytes) 18:23:35.708 SERIAL » [ACK] (0x06) 18:23:35.711 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:35.710 DRIVER ACK received from node for current transaction. RTT = 1607.48 ms 18:23:38.319 CNTRLR [Node 005] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:23:38.819 DRIVER » [Node 005] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:23:38.820 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:23:38.824 SERIAL « [ACK] (0x06) 18:23:38.825 DRIVER ACK received from controller for current transaction 18:23:38.825 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:38.831 SERIAL « 0x01 (1 bytes) 18:23:38.831 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:23:38.833 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:23:38.832 SERIAL « 0x04011301e8 (5 bytes) 18:23:38.832 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:23:38.833 SERIAL » [ACK] (0x06) 18:23:38.834 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:38.847 SERIAL « 0x01 (1 bytes) 18:23:38.848 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:23:38.850 SERIAL « 0x07001356000002bf (8 bytes) 18:23:38.851 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:23:38.850 SERIAL Buffer := 0x0107001356000002bf (9 bytes) 18:23:38.850 SERIAL » [ACK] (0x06) 18:23:38.852 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:38.852 DRIVER ACK received from node for current transaction. RTT = 4748.98 ms 18:23:44.101 DRIVER The awake timeout for node 5 has elapsed. Assuming it is asleep. 18:23:44.102 CNTRLR [Node 005] The node is now asleep. 18:23:44.103 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:23:44.104 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:23:53.841 SERIAL « 0x01 (1 bytes) 18:23:53.842 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:23:53.844 SERIAL « 0x0900040004038003285e (10 bytes) 18:23:53.846 CNTRLR [Node 004] [~] [Battery] level: 40 => 40 [Endpoint 0] 18:23:53.844 SERIAL Buffer := 0x010900040004038003285e (11 bytes) 18:23:53.849 SERIAL » [ACK] (0x06) 18:23:53.850 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:53.848 CNTRLR [Node 004] [~] [Battery] isLow: false => false [Endpoint 0] 18:23:53.864 SERIAL « 0x01 (1 bytes) 18:23:53.864 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:23:53.868 CNTRLR [Node 004] [~] [Thermostat Setpoint] setpoint[1]: 5 => 5 [Endpoint 0] 18:23:53.866 SERIAL « 0x0c00040004064303014201f403 (13 bytes) 18:23:53.867 SERIAL Buffer := 0x010c00040004064303014201f403 (14 bytes) 18:23:53.870 SERIAL » [ACK] (0x06) 18:23:53.870 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:53.884 SERIAL « 0x01 (1 bytes) 18:23:53.884 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:23:53.886 SERIAL « 0x0a00040004044608007fc0 (11 bytes) 18:23:53.888 CNTRLR [Node 004] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:23:53.886 SERIAL Buffer := 0x010a00040004044608007fc0 (12 bytes) 18:23:53.891 SERIAL » [ACK] (0x06) 18:23:53.891 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:53.889 CNTRLR [Node 004] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:23:53.905 SERIAL « 0x01 (1 bytes) 18:23:53.906 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:23:53.908 CNTRLR « [Node 004] received wakeup notification 18:23:53.913 DRIVER » [Node 004] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:23:53.907 SERIAL « 0x080004000402840776 (9 bytes) 18:23:53.907 SERIAL Buffer := 0x01080004000402840776 (10 bytes) 18:23:53.908 SERIAL » [ACK] (0x06) 18:23:53.912 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:53.915 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:23:53.910 CNTRLR [Node 004] The node is now awake. 18:23:53.920 SERIAL « [ACK] (0x06) 18:23:53.921 DRIVER Unexpected ACK received 18:23:53.921 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:53.927 SERIAL « 0x01 (1 bytes) 18:23:53.927 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:23:53.929 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:23:53.928 SERIAL « 0x04011301e8 (5 bytes) 18:23:53.928 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:23:53.929 SERIAL » [ACK] (0x06) 18:23:53.930 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:53.944 SERIAL « 0x01 (1 bytes) 18:23:53.945 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:23:53.946 SERIAL « 0x070013620000038a (8 bytes) 18:23:53.947 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:23:53.946 SERIAL Buffer := 0x01070013620000038a (9 bytes) 18:23:53.947 SERIAL » [ACK] (0x06) 18:23:53.948 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:53.948 DRIVER ACK received from node for current transaction. RTT = 34.83 ms 18:23:54.983 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:23:55.485 DRIVER » [Node 004] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:23:55.485 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:23:55.489 SERIAL « [ACK] (0x06) 18:23:55.489 DRIVER ACK received from controller for current transaction 18:23:55.489 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:55.495 SERIAL « 0x01 (1 bytes) 18:23:55.496 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:23:55.498 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:23:55.497 SERIAL « 0x04011301e8 (5 bytes) 18:23:55.497 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:23:55.498 SERIAL » [ACK] (0x06) 18:23:55.499 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:55.512 SERIAL « 0x01 (1 bytes) 18:23:55.512 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:23:55.513 SERIAL « 0x070013620000038a (8 bytes) 18:23:55.515 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:23:55.514 SERIAL Buffer := 0x01070013620000038a (9 bytes) 18:23:55.514 SERIAL » [ACK] (0x06) 18:23:55.516 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:55.515 DRIVER ACK received from node for current transaction. RTT = 1602.45 ms 18:23:58.118 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:23:58.619 DRIVER » [Node 004] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:23:58.621 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:23:58.624 SERIAL « [ACK] (0x06) 18:23:58.625 DRIVER ACK received from controller for current transaction 18:23:58.625 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:58.631 SERIAL « 0x01 (1 bytes) 18:23:58.631 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:23:58.633 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:23:58.632 SERIAL « 0x04011301e8 (5 bytes) 18:23:58.632 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:23:58.633 SERIAL » [ACK] (0x06) 18:23:58.634 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:58.647 SERIAL « 0x01 (1 bytes) 18:23:58.648 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:23:58.650 SERIAL « 0x070013620000028b (8 bytes) 18:23:58.652 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:23:58.651 SERIAL Buffer := 0x01070013620000028b (9 bytes) 18:23:58.652 SERIAL » [ACK] (0x06) 18:23:58.656 SERIAL The receive buffer is empty, waiting for the next chunk... 18:23:58.653 DRIVER ACK received from node for current transaction. RTT = 4740.35 ms 18:24:03.911 DRIVER The awake timeout for node 4 has elapsed. Assuming it is asleep. 18:24:03.912 CNTRLR [Node 004] The node is now asleep. 18:24:03.914 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:24:03.915 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:24:39.485 SERIAL « 0x01 (1 bytes) 18:24:39.486 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:24:39.488 CNTRLR [Node 006] [~] [Battery] level: 80 => 80 [Endpoint 0] 18:24:39.487 SERIAL « 0x09000400060380035024 (10 bytes) 18:24:39.487 SERIAL Buffer := 0x0109000400060380035024 (11 bytes) 18:24:39.492 SERIAL » [ACK] (0x06) 18:24:39.493 SERIAL The receive buffer is empty, waiting for the next chunk... 18:24:39.491 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 0] 18:24:39.506 SERIAL « 0x01 (1 bytes) 18:24:39.508 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:24:39.510 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpoint[1]: 4 => 4 [Endpoint 0] 18:24:39.509 SERIAL « 0x0c000400060643030142019065 (13 bytes) 18:24:39.509 SERIAL Buffer := 0x010c000400060643030142019065 (14 bytes) 18:24:39.512 SERIAL » [ACK] (0x06) 18:24:39.512 SERIAL The receive buffer is empty, waiting for the next chunk... 18:24:39.526 SERIAL « 0x01 (1 bytes) 18:24:39.527 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:24:39.528 SERIAL « 0x0a00040006044608007fc2 (11 bytes) 18:24:39.530 CNTRLR [Node 006] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:24:39.532 CNTRLR [Node 006] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:24:39.529 SERIAL Buffer := 0x010a00040006044608007fc2 (12 bytes) 18:24:39.533 SERIAL » [ACK] (0x06) 18:24:39.534 SERIAL The receive buffer is empty, waiting for the next chunk... 18:24:39.548 SERIAL « 0x01080004000602840774 (10 bytes) 18:24:39.550 CNTRLR « [Node 006] received wakeup notification 18:24:39.554 DRIVER » [Node 006] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:24:39.549 SERIAL Buffer := 0x01080004000602840774 (10 bytes) 18:24:39.550 SERIAL » [ACK] (0x06) 18:24:39.553 SERIAL The receive buffer is empty, waiting for the next chunk... 18:24:39.555 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:24:39.551 CNTRLR [Node 006] The node is now awake. 18:24:39.560 SERIAL « [ACK] (0x06) 18:24:39.561 DRIVER Unexpected ACK received 18:24:39.561 SERIAL The receive buffer is empty, waiting for the next chunk... 18:24:39.566 SERIAL « 0x01 (1 bytes) 18:24:39.566 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:24:39.569 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:24:39.568 SERIAL « 0x04011301e8 (5 bytes) 18:24:39.568 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:24:39.568 SERIAL » [ACK] (0x06) 18:24:39.570 SERIAL The receive buffer is empty, waiting for the next chunk... 18:24:39.583 SERIAL « 0x01 (1 bytes) 18:24:39.584 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:24:39.586 SERIAL « 0x0700136e00000386 (8 bytes) 18:24:39.588 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:24:39.587 SERIAL Buffer := 0x010700136e00000386 (9 bytes) 18:24:39.587 SERIAL » [ACK] (0x06) 18:24:39.589 SERIAL The receive buffer is empty, waiting for the next chunk... 18:24:39.588 DRIVER ACK received from node for current transaction. RTT = 34.72 ms 18:24:40.623 CNTRLR [Node 006] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:24:41.124 DRIVER » [Node 006] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:24:41.125 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:24:41.129 SERIAL « [ACK] (0x06) 18:24:41.130 DRIVER ACK received from controller for current transaction 18:24:41.130 SERIAL The receive buffer is empty, waiting for the next chunk... 18:24:41.136 SERIAL « 0x01 (1 bytes) 18:24:41.136 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:24:41.138 SERIAL « 0x04011301e8 (5 bytes) 18:24:41.139 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:24:41.138 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:24:41.138 SERIAL » [ACK] (0x06) 18:24:41.139 SERIAL The receive buffer is empty, waiting for the next chunk... 18:24:41.153 SERIAL « 0x01 (1 bytes) 18:24:41.153 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:24:41.156 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:24:41.154 SERIAL « 0x0700136e00000386 (8 bytes) 18:24:41.155 SERIAL Buffer := 0x010700136e00000386 (9 bytes) 18:24:41.155 SERIAL » [ACK] (0x06) 18:24:41.156 SERIAL The receive buffer is empty, waiting for the next chunk... 18:24:41.156 DRIVER ACK received from node for current transaction. RTT = 1602.59 ms 18:24:43.759 CNTRLR [Node 006] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:24:44.259 DRIVER » [Node 006] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:24:44.260 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:24:44.264 SERIAL « [ACK] (0x06) 18:24:44.265 DRIVER ACK received from controller for current transaction 18:24:44.265 SERIAL The receive buffer is empty, waiting for the next chunk... 18:24:44.270 SERIAL « 0x01 (1 bytes) 18:24:44.271 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:24:44.273 SERIAL « 0x04011301e8 (5 bytes) 18:24:44.274 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:24:44.273 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:24:44.273 SERIAL » [ACK] (0x06) 18:24:44.274 SERIAL The receive buffer is empty, waiting for the next chunk... 18:24:44.288 SERIAL « 0x01 (1 bytes) 18:24:44.288 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:24:44.290 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:24:44.289 SERIAL « 0x0700136e00000287 (8 bytes) 18:24:44.290 SERIAL Buffer := 0x010700136e00000287 (9 bytes) 18:24:44.290 SERIAL » [ACK] (0x06) 18:24:44.292 SERIAL The receive buffer is empty, waiting for the next chunk... 18:24:44.291 DRIVER ACK received from node for current transaction. RTT = 4737.52 ms 18:24:49.553 DRIVER The awake timeout for node 6 has elapsed. Assuming it is asleep. 18:24:49.553 CNTRLR [Node 006] The node is now asleep. 18:24:49.557 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:24:49.558 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:25:08.307 SERIAL « 0x01 (1 bytes) 18:25:08.307 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:25:08.310 CNTRLR [Node 003] [~] [Battery] level: 51 => 51 [Endpoint 0] 18:25:08.309 SERIAL « 0x09000400030380033342 (10 bytes) 18:25:08.309 SERIAL Buffer := 0x0109000400030380033342 (11 bytes) 18:25:08.313 SERIAL » [ACK] (0x06) 18:25:08.314 SERIAL The receive buffer is empty, waiting for the next chunk... 18:25:08.312 CNTRLR [Node 003] [~] [Battery] isLow: false => false [Endpoint 0] 18:25:08.328 SERIAL « 0x01 (1 bytes) 18:25:08.329 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:25:08.332 SERIAL « 0x0c0004000306430301420708fe (13 bytes) 18:25:08.333 CNTRLR [Node 003] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:25:08.332 SERIAL Buffer := 0x010c0004000306430301420708fe (14 bytes) 18:25:08.335 SERIAL » [ACK] (0x06) 18:25:08.336 SERIAL The receive buffer is empty, waiting for the next chunk... 18:25:08.349 SERIAL « 0x01 (1 bytes) 18:25:08.349 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:25:08.352 CNTRLR [Node 003] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:25:08.350 SERIAL « 0x0a00040003044608007fc7 (11 bytes) 18:25:08.351 SERIAL Buffer := 0x010a00040003044608007fc7 (12 bytes) 18:25:08.355 SERIAL » [ACK] (0x06) 18:25:08.356 SERIAL The receive buffer is empty, waiting for the next chunk... 18:25:08.354 CNTRLR [Node 003] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:25:08.368 SERIAL « 0x01 (1 bytes) 18:25:08.368 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:25:08.372 CNTRLR « [Node 003] received wakeup notification 18:25:08.370 SERIAL « 0x080004000302840771 (9 bytes) 18:25:08.371 SERIAL Buffer := 0x01080004000302840771 (10 bytes) 18:25:08.372 SERIAL » [ACK] (0x06) 18:25:08.374 SERIAL The receive buffer is empty, waiting for the next chunk... 18:25:08.376 DRIVER » [Node 003] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 122 └─[ThermostatSetpointCCGet] payload: 0x02 18:25:08.373 CNTRLR [Node 003] The node is now awake. 18:25:08.377 SERIAL » 0x010a00130303430202257afa (12 bytes) 18:25:08.381 SERIAL « [ACK] (0x06) 18:25:08.381 DRIVER Unexpected ACK received 18:25:08.382 SERIAL The receive buffer is empty, waiting for the next chunk... 18:25:08.387 SERIAL « 0x01 (1 bytes) 18:25:08.388 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:25:08.389 SERIAL « 0x04011301e8 (5 bytes) 18:25:08.390 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:25:08.390 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:25:08.390 SERIAL » [ACK] (0x06) 18:25:08.391 SERIAL The receive buffer is empty, waiting for the next chunk... 18:25:08.404 SERIAL « 0x01 (1 bytes) 18:25:08.405 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:25:08.407 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 18:25:08.405 SERIAL « 0x0700137a00000293 (8 bytes) 18:25:08.406 SERIAL Buffer := 0x010700137a00000293 (9 bytes) 18:25:08.406 SERIAL » [ACK] (0x06) 18:25:08.408 SERIAL The receive buffer is empty, waiting for the next chunk... 18:25:08.407 DRIVER ACK received from node for current transaction. RTT = 32.10 ms 18:25:09.441 CNTRLR [Node 003] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:25:09.941 DRIVER » [Node 003] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 122 └─[ThermostatSetpointCCGet] payload: 0x02 18:25:09.942 SERIAL » 0x010a00130303430202257afa (12 bytes) 18:25:09.946 SERIAL « [ACK] (0x06) 18:25:09.947 DRIVER ACK received from controller for current transaction 18:25:09.949 SERIAL The receive buffer is empty, waiting for the next chunk... 18:25:09.953 SERIAL « 0x01 (1 bytes) 18:25:09.953 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:25:09.957 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:25:09.956 SERIAL « 0x04011301e8 (5 bytes) 18:25:09.956 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:25:09.957 SERIAL » [ACK] (0x06) 18:25:09.958 SERIAL The receive buffer is empty, waiting for the next chunk... 18:25:09.970 SERIAL « 0x01 (1 bytes) 18:25:09.970 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:25:09.972 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 18:25:09.971 SERIAL « 0x0700137a00000293 (8 bytes) 18:25:09.971 SERIAL Buffer := 0x010700137a00000293 (9 bytes) 18:25:09.972 SERIAL » [ACK] (0x06) 18:25:09.973 SERIAL The receive buffer is empty, waiting for the next chunk... 18:25:09.973 DRIVER ACK received from node for current transaction. RTT = 1597.32 ms 18:25:12.571 CNTRLR [Node 003] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:25:13.072 DRIVER » [Node 003] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 122 └─[ThermostatSetpointCCGet] payload: 0x02 18:25:13.072 SERIAL » 0x010a00130303430202257afa (12 bytes) 18:25:13.077 SERIAL « [ACK] (0x06) 18:25:13.077 DRIVER ACK received from controller for current transaction 18:25:13.078 SERIAL The receive buffer is empty, waiting for the next chunk... 18:25:13.083 SERIAL « 0x01 (1 bytes) 18:25:13.084 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:25:13.086 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:25:13.085 SERIAL « 0x04011301e8 (5 bytes) 18:25:13.085 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:25:13.086 SERIAL » [ACK] (0x06) 18:25:13.087 SERIAL The receive buffer is empty, waiting for the next chunk... 18:25:13.100 SERIAL « 0x01 (1 bytes) 18:25:13.100 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:25:13.104 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 18:25:13.104 DRIVER ACK received from node for current transaction. RTT = 4728.76 ms 18:25:13.102 SERIAL « 0x0700137a00000293 (8 bytes) 18:25:13.103 SERIAL Buffer := 0x010700137a00000293 (9 bytes) 18:25:13.103 SERIAL » [ACK] (0x06) 18:25:13.105 SERIAL The receive buffer is empty, waiting for the next chunk... 18:25:18.375 DRIVER The awake timeout for node 3 has elapsed. Assuming it is asleep. 18:25:18.375 CNTRLR [Node 003] The node is now asleep. 18:25:18.377 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:25:18.378 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:26:00.037 SERIAL « 0x01 (1 bytes) 18:26:00.037 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:26:00.038 SERIAL « 0x09000400080380034832 (10 bytes) 18:26:00.040 CNTRLR [Node 008] [~] [Battery] level: 72 => 72 [Endpoint 0] 18:26:00.039 SERIAL Buffer := 0x0109000400080380034832 (11 bytes) 18:26:00.043 SERIAL » [ACK] (0x06) 18:26:00.044 SERIAL The receive buffer is empty, waiting for the next chunk... 18:26:00.042 CNTRLR [Node 008] [~] [Battery] isLow: false => false [Endpoint 0] 18:26:00.059 SERIAL « 0x01 (1 bytes) 18:26:00.059 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:26:00.063 CNTRLR [Node 008] [~] [Thermostat Setpoint] setpoint[1]: 4.5 => 4.5 [Endpoint 0] 18:26:00.061 SERIAL « 0x0c00040008064303014201c239 (13 bytes) 18:26:00.062 SERIAL Buffer := 0x010c00040008064303014201c239 (14 bytes) 18:26:00.064 SERIAL » [ACK] (0x06) 18:26:00.065 SERIAL The receive buffer is empty, waiting for the next chunk... 18:26:00.079 SERIAL « 0x01 (1 bytes) 18:26:00.080 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:26:00.083 CNTRLR [Node 008] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:26:00.082 SERIAL « 0x0a00040008044608007fcc (11 bytes) 18:26:00.082 SERIAL Buffer := 0x010a00040008044608007fcc (12 bytes) 18:26:00.086 SERIAL » [ACK] (0x06) 18:26:00.097 SERIAL The receive buffer is empty, waiting for the next chunk... 18:26:00.085 CNTRLR [Node 008] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:26:00.100 SERIAL « 0x01 (1 bytes) 18:26:00.101 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:26:00.104 CNTRLR [Node 008] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 18:26:00.102 SERIAL « 0x0c000400080631050142079e17 (13 bytes) 18:26:00.102 SERIAL Buffer := 0x010c000400080631050142079e17 (14 bytes) 18:26:00.107 SERIAL » [ACK] (0x06) 18:26:00.108 SERIAL The receive buffer is empty, waiting for the next chunk... 18:26:00.106 CNTRLR [Node 008] [~] [Multilevel Sensor] Air temperature: 19.44 => 19.5 [Endpoint 0] 18:26:00.120 SERIAL « 0x01 (1 bytes) 18:26:00.121 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:26:00.125 CNTRLR « [Node 008] received wakeup notification 18:26:00.123 SERIAL « 0x08000400080284077a (9 bytes) 18:26:00.123 SERIAL Buffer := 0x0108000400080284077a (10 bytes) 18:26:00.124 SERIAL » [ACK] (0x06) 18:26:00.128 SERIAL The receive buffer is empty, waiting for the next chunk... 18:26:00.130 DRIVER » [Node 008] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:26:00.126 CNTRLR [Node 008] The node is now awake. 18:26:00.130 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:26:00.136 SERIAL « [ACK] (0x06) 18:26:00.137 DRIVER Unexpected ACK received 18:26:00.138 SERIAL The receive buffer is empty, waiting for the next chunk... 18:26:00.141 SERIAL « 0x01 (1 bytes) 18:26:00.141 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:26:00.146 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:26:00.145 SERIAL « 0x04011301e8 (5 bytes) 18:26:00.145 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:26:00.145 SERIAL » [ACK] (0x06) 18:26:00.146 SERIAL The receive buffer is empty, waiting for the next chunk... 18:26:00.158 SERIAL « 0x01 (1 bytes) 18:26:00.159 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:26:00.161 SERIAL « 0x0700138a00000263 (8 bytes) 18:26:00.162 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:26:00.163 DRIVER ACK received from node for current transaction. RTT = 33.76 ms 18:26:00.162 SERIAL Buffer := 0x010700138a00000263 (9 bytes) 18:26:00.162 SERIAL » [ACK] (0x06) 18:26:00.164 SERIAL The receive buffer is empty, waiting for the next chunk... 18:26:01.197 CNTRLR [Node 008] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:26:01.698 DRIVER » [Node 008] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:26:01.698 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:26:01.702 SERIAL « [ACK] (0x06) 18:26:01.702 DRIVER ACK received from controller for current transaction 18:26:01.703 SERIAL The receive buffer is empty, waiting for the next chunk... 18:26:01.708 SERIAL « 0x01 (1 bytes) 18:26:01.709 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:26:01.711 SERIAL « 0x04011301e8 (5 bytes) 18:26:01.713 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:26:01.712 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:26:01.712 SERIAL » [ACK] (0x06) 18:26:01.715 SERIAL The receive buffer is empty, waiting for the next chunk... 18:26:01.730 SERIAL « 0x01 (1 bytes) 18:26:01.730 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:26:01.733 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:26:01.731 SERIAL « 0x0700138a00000263 (8 bytes) 18:26:01.732 SERIAL Buffer := 0x010700138a00000263 (9 bytes) 18:26:01.732 SERIAL » [ACK] (0x06) 18:26:01.734 SERIAL The receive buffer is empty, waiting for the next chunk... 18:26:01.733 DRIVER ACK received from node for current transaction. RTT = 1604.27 ms 18:26:04.339 CNTRLR [Node 008] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:26:04.839 DRIVER » [Node 008] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:26:04.840 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:26:04.844 SERIAL « [ACK] (0x06) 18:26:04.844 DRIVER ACK received from controller for current transaction 18:26:04.845 SERIAL The receive buffer is empty, waiting for the next chunk... 18:26:04.851 SERIAL « 0x01 (1 bytes) 18:26:04.851 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:26:04.853 SERIAL « 0x04011301e8 (5 bytes) 18:26:04.854 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:26:04.853 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:26:04.853 SERIAL » [ACK] (0x06) 18:26:04.857 SERIAL The receive buffer is empty, waiting for the next chunk... 18:26:04.867 SERIAL « 0x01 (1 bytes) 18:26:04.868 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:26:04.869 SERIAL « 0x0700138a00000263 (8 bytes) 18:26:04.870 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:26:04.870 SERIAL Buffer := 0x010700138a00000263 (9 bytes) 18:26:04.870 SERIAL » [ACK] (0x06) 18:26:04.871 SERIAL The receive buffer is empty, waiting for the next chunk... 18:26:04.871 DRIVER ACK received from node for current transaction. RTT = 4741.65 ms 18:26:10.127 DRIVER The awake timeout for node 8 has elapsed. Assuming it is asleep. 18:26:10.128 CNTRLR [Node 008] The node is now asleep. 18:26:10.129 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:26:10.130 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:27:04.873 SERIAL « 0x01 (1 bytes) 18:27:04.873 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:27:04.875 SERIAL « 0x09000400020380035020 (10 bytes) 18:27:04.877 CNTRLR [Node 002] [~] [Battery] level: 80 => 80 [Endpoint 0] 18:27:04.876 SERIAL Buffer := 0x0109000400020380035020 (11 bytes) 18:27:04.881 SERIAL » [ACK] (0x06) 18:27:04.882 SERIAL The receive buffer is empty, waiting for the next chunk... 18:27:04.878 CNTRLR [Node 002] [~] [Battery] isLow: false => false [Endpoint 0] 18:27:04.896 SERIAL « 0x010c (2 bytes) 18:27:04.897 SERIAL [incomplete] Buffer := 0x010c (2 bytes) 18:27:04.899 SERIAL « 0x0004000206430301420708ff (12 bytes) 18:27:04.902 CNTRLR [Node 002] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:27:04.900 SERIAL Buffer := 0x010c0004000206430301420708ff (14 bytes) 18:27:04.904 SERIAL » [ACK] (0x06) 18:27:04.904 SERIAL The receive buffer is empty, waiting for the next chunk... 18:27:04.915 SERIAL « 0x01 (1 bytes) 18:27:04.915 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:27:04.917 SERIAL « 0x0a00040002044608007fc6 (11 bytes) 18:27:04.919 CNTRLR [Node 002] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:27:04.917 SERIAL Buffer := 0x010a00040002044608007fc6 (12 bytes) 18:27:04.922 SERIAL » [ACK] (0x06) 18:27:04.922 SERIAL The receive buffer is empty, waiting for the next chunk... 18:27:04.920 CNTRLR [Node 002] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:27:04.937 SERIAL « 0x01 (1 bytes) 18:27:04.938 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:27:04.940 CNTRLR « [Node 002] received wakeup notification 18:27:04.943 DRIVER » [Node 002] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:27:04.938 SERIAL « 0x080004000202840770 (9 bytes) 18:27:04.939 SERIAL Buffer := 0x01080004000202840770 (10 bytes) 18:27:04.939 SERIAL » [ACK] (0x06) 18:27:04.942 SERIAL The receive buffer is empty, waiting for the next chunk... 18:27:04.947 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:27:04.940 CNTRLR [Node 002] The node is now awake. 18:27:04.953 SERIAL « [ACK] (0x06) 18:27:04.954 DRIVER Unexpected ACK received 18:27:04.954 SERIAL The receive buffer is empty, waiting for the next chunk... 18:27:04.959 SERIAL « 0x01 (1 bytes) 18:27:04.959 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:27:04.962 SERIAL « 0x04011301e8 (5 bytes) 18:27:04.963 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:27:04.962 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:27:04.963 SERIAL » [ACK] (0x06) 18:27:04.964 SERIAL The receive buffer is empty, waiting for the next chunk... 18:27:04.975 SERIAL « 0x01 (1 bytes) 18:27:04.975 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:27:04.977 SERIAL « 0x0700134a000002a3 (8 bytes) 18:27:04.979 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:27:04.978 SERIAL Buffer := 0x010700134a000002a3 (9 bytes) 18:27:04.978 SERIAL » [ACK] (0x06) 18:27:04.980 SERIAL The receive buffer is empty, waiting for the next chunk... 18:27:04.979 DRIVER ACK received from node for current transaction. RTT = 36.56 ms 18:27:06.017 CNTRLR [Node 002] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:27:06.517 DRIVER » [Node 002] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:27:06.518 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:27:06.524 SERIAL « [ACK] (0x06) 18:27:06.525 DRIVER ACK received from controller for current transaction 18:27:06.525 SERIAL The receive buffer is empty, waiting for the next chunk... 18:27:06.531 SERIAL « 0x01 (1 bytes) 18:27:06.531 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:27:06.533 SERIAL « 0x04011301e8 (5 bytes) 18:27:06.534 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:27:06.533 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:27:06.534 SERIAL » [ACK] (0x06) 18:27:06.534 SERIAL The receive buffer is empty, waiting for the next chunk... 18:27:06.548 SERIAL « 0x01 (1 bytes) 18:27:06.548 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:27:06.550 SERIAL « 0x0700134a000002a3 (8 bytes) 18:27:06.552 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:27:06.551 SERIAL Buffer := 0x010700134a000002a3 (9 bytes) 18:27:06.551 SERIAL » [ACK] (0x06) 18:27:06.553 SERIAL The receive buffer is empty, waiting for the next chunk... 18:27:06.552 DRIVER ACK received from node for current transaction. RTT = 1609.21 ms 18:27:09.162 CNTRLR [Node 002] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:27:09.664 DRIVER » [Node 002] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:27:09.664 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:27:09.668 SERIAL « [ACK] (0x06) 18:27:09.668 DRIVER ACK received from controller for current transaction 18:27:09.669 SERIAL The receive buffer is empty, waiting for the next chunk... 18:27:09.675 SERIAL « 0x01 (1 bytes) 18:27:09.675 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:27:09.677 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:27:09.676 SERIAL « 0x04011301e8 (5 bytes) 18:27:09.677 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:27:09.677 SERIAL » [ACK] (0x06) 18:27:09.678 SERIAL The receive buffer is empty, waiting for the next chunk... 18:27:09.692 SERIAL « 0x01 (1 bytes) 18:27:09.692 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:27:09.694 SERIAL « 0x0700134a000002a3 (8 bytes) 18:27:09.695 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:27:09.694 SERIAL Buffer := 0x010700134a000002a3 (9 bytes) 18:27:09.694 SERIAL » [ACK] (0x06) 18:27:09.696 SERIAL The receive buffer is empty, waiting for the next chunk... 18:27:09.696 DRIVER ACK received from node for current transaction. RTT = 4752.85 ms 18:27:14.941 DRIVER The awake timeout for node 2 has elapsed. Assuming it is asleep. 18:27:14.942 CNTRLR [Node 002] The node is now asleep. 18:27:14.944 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:27:14.944 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:28:27.325 SERIAL « 0x01 (1 bytes) 18:28:27.326 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:28:27.327 SERIAL « 0x09000400050380033a4d (10 bytes) 18:28:27.329 CNTRLR [Node 005] [~] [Battery] level: 58 => 58 [Endpoint 0] 18:28:27.328 SERIAL Buffer := 0x0109000400050380033a4d (11 bytes) 18:28:27.332 SERIAL » [ACK] (0x06) 18:28:27.332 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:27.331 CNTRLR [Node 005] [~] [Battery] isLow: false => false [Endpoint 0] 18:28:27.346 SERIAL « 0x01 (1 bytes) 18:28:27.347 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:28:27.350 CNTRLR [Node 005] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:28:27.348 SERIAL « 0x0c0004000506430301420708f8 (13 bytes) 18:28:27.349 SERIAL Buffer := 0x010c0004000506430301420708f8 (14 bytes) 18:28:27.352 SERIAL » [ACK] (0x06) 18:28:27.352 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:27.367 SERIAL « 0x01 (1 bytes) 18:28:27.368 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:28:27.369 SERIAL « 0x0a00040005044608007fc1 (11 bytes) 18:28:27.370 CNTRLR [Node 005] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:28:27.369 SERIAL Buffer := 0x010a00040005044608007fc1 (12 bytes) 18:28:27.374 SERIAL » [ACK] (0x06) 18:28:27.375 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:27.372 CNTRLR [Node 005] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:28:27.387 SERIAL « 0x01 (1 bytes) 18:28:27.388 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:28:27.391 CNTRLR « [Node 005] received wakeup notification 18:28:27.394 DRIVER » [Node 005] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:28:27.389 SERIAL « 0x080004000502840777 (9 bytes) 18:28:27.390 SERIAL Buffer := 0x01080004000502840777 (10 bytes) 18:28:27.390 SERIAL » [ACK] (0x06) 18:28:27.393 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:27.395 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:28:27.391 CNTRLR [Node 005] The node is now awake. 18:28:27.401 SERIAL « [ACK] (0x06) 18:28:27.401 DRIVER Unexpected ACK received 18:28:27.402 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:27.406 SERIAL « 0x01 (1 bytes) 18:28:27.407 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:28:27.409 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:28:27.408 SERIAL « 0x04011301e8 (5 bytes) 18:28:27.408 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:28:27.408 SERIAL » [ACK] (0x06) 18:28:27.409 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:27.423 SERIAL « 0x01 (1 bytes) 18:28:27.424 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:28:27.425 SERIAL « 0x07001356000003be (8 bytes) 18:28:27.426 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:28:27.427 DRIVER ACK received from node for current transaction. RTT = 32.59 ms 18:28:27.426 SERIAL Buffer := 0x0107001356000003be (9 bytes) 18:28:27.426 SERIAL » [ACK] (0x06) 18:28:27.427 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:28.460 CNTRLR [Node 005] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:28:28.960 DRIVER » [Node 005] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:28:28.961 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:28:28.964 SERIAL « [ACK] (0x06) 18:28:28.966 DRIVER ACK received from controller for current transaction 18:28:28.969 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:28.975 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:28:28.974 SERIAL « 0x0104011301e8 (6 bytes) 18:28:28.974 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:28:28.975 SERIAL » [ACK] (0x06) 18:28:28.976 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:28.988 SERIAL « 0x01 (1 bytes) 18:28:28.988 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:28:28.989 SERIAL « 0x07001356000002bf (8 bytes) 18:28:28.991 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:28:28.990 SERIAL Buffer := 0x0107001356000002bf (9 bytes) 18:28:28.990 SERIAL » [ACK] (0x06) 18:28:28.992 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:28.991 DRIVER ACK received from node for current transaction. RTT = 1596.99 ms 18:28:31.589 CNTRLR [Node 005] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:28:32.089 DRIVER » [Node 005] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:28:32.090 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:28:32.096 SERIAL « [ACK] (0x06) 18:28:32.096 DRIVER ACK received from controller for current transaction 18:28:32.097 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:32.101 SERIAL « 0x01 (1 bytes) 18:28:32.102 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:28:32.105 SERIAL « 0x04011301e8 (5 bytes) 18:28:32.106 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:28:32.105 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:28:32.105 SERIAL » [ACK] (0x06) 18:28:32.106 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:32.119 SERIAL « 0x01 (1 bytes) 18:28:32.120 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:28:32.121 SERIAL « 0x07001356000002bf (8 bytes) 18:28:32.122 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:28:32.122 DRIVER ACK received from node for current transaction. RTT = 4728.27 ms 18:28:32.121 SERIAL Buffer := 0x0107001356000002bf (9 bytes) 18:28:32.122 SERIAL » [ACK] (0x06) 18:28:32.123 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:37.393 DRIVER The awake timeout for node 5 has elapsed. Assuming it is asleep. 18:28:37.394 CNTRLR [Node 005] The node is now asleep. 18:28:37.397 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:28:37.398 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:28:52.016 SERIAL « 0x01 (1 bytes) 18:28:52.016 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:28:52.018 CNTRLR [Node 004] [~] [Battery] level: 40 => 40 [Endpoint 0] 18:28:52.017 SERIAL « 0x0900040004038003285e (10 bytes) 18:28:52.017 SERIAL Buffer := 0x010900040004038003285e (11 bytes) 18:28:52.021 SERIAL » [ACK] (0x06) 18:28:52.022 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:52.020 CNTRLR [Node 004] [~] [Battery] isLow: false => false [Endpoint 0] 18:28:52.037 SERIAL « 0x01 (1 bytes) 18:28:52.037 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:28:52.041 CNTRLR [Node 004] [~] [Thermostat Setpoint] setpoint[1]: 5 => 5 [Endpoint 0] 18:28:52.039 SERIAL « 0x0c00040004064303014201f403 (13 bytes) 18:28:52.039 SERIAL Buffer := 0x010c00040004064303014201f403 (14 bytes) 18:28:52.042 SERIAL » [ACK] (0x06) 18:28:52.043 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:52.057 SERIAL « 0x01 (1 bytes) 18:28:52.058 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:28:52.060 SERIAL « 0x0a00040004044608007fc0 (11 bytes) 18:28:52.061 CNTRLR [Node 004] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:28:52.060 SERIAL Buffer := 0x010a00040004044608007fc0 (12 bytes) 18:28:52.064 SERIAL » [ACK] (0x06) 18:28:52.065 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:52.063 CNTRLR [Node 004] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:28:52.078 SERIAL « 0x01 (1 bytes) 18:28:52.079 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:28:52.082 CNTRLR « [Node 004] received wakeup notification 18:28:52.086 DRIVER » [Node 004] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:28:52.081 SERIAL « 0x080004000402840776 (9 bytes) 18:28:52.081 SERIAL Buffer := 0x01080004000402840776 (10 bytes) 18:28:52.082 SERIAL » [ACK] (0x06) 18:28:52.084 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:52.087 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:28:52.083 CNTRLR [Node 004] The node is now awake. 18:28:52.102 SERIAL « [ACK] (0x06) 18:28:52.102 DRIVER Unexpected ACK received 18:28:52.103 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:52.105 SERIAL « 0x01 (1 bytes) 18:28:52.106 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:28:52.108 SERIAL « 0x04011301e8 (5 bytes) 18:28:52.112 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:28:52.111 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:28:52.112 SERIAL » [ACK] (0x06) 18:28:52.113 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:52.122 SERIAL « 0x01 (1 bytes) 18:28:52.123 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:28:52.125 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:28:52.124 SERIAL « 0x070013620000028b (8 bytes) 18:28:52.124 SERIAL Buffer := 0x01070013620000028b (9 bytes) 18:28:52.124 SERIAL » [ACK] (0x06) 18:28:52.126 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:52.125 DRIVER ACK received from node for current transaction. RTT = 39.53 ms 18:28:53.166 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:28:53.667 DRIVER » [Node 004] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:28:53.669 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:28:53.673 SERIAL « [ACK] (0x06) 18:28:53.674 DRIVER ACK received from controller for current transaction 18:28:53.674 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:53.680 SERIAL « 0x01 (1 bytes) 18:28:53.681 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:28:53.683 SERIAL « 0x04011301e8 (5 bytes) 18:28:53.684 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:28:53.684 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:28:53.684 SERIAL » [ACK] (0x06) 18:28:53.685 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:53.697 SERIAL « 0x01 (1 bytes) 18:28:53.697 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:28:53.698 SERIAL « 0x070013620000028b (8 bytes) 18:28:53.700 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:28:53.699 SERIAL Buffer := 0x01070013620000028b (9 bytes) 18:28:53.699 SERIAL » [ACK] (0x06) 18:28:53.700 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:53.700 DRIVER ACK received from node for current transaction. RTT = 1614.29 ms 18:28:56.315 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:28:56.817 DRIVER » [Node 004] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:28:56.817 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:28:56.821 SERIAL « [ACK] (0x06) 18:28:56.822 DRIVER ACK received from controller for current transaction 18:28:56.822 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:56.828 SERIAL « 0x01 (1 bytes) 18:28:56.829 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:28:56.831 SERIAL « 0x04011301e8 (5 bytes) 18:28:56.832 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:28:56.831 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:28:56.831 SERIAL » [ACK] (0x06) 18:28:56.832 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:56.845 SERIAL « 0x01 (1 bytes) 18:28:56.845 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:28:56.847 SERIAL « 0x070013620000038a (8 bytes) 18:28:56.848 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:28:56.847 SERIAL Buffer := 0x01070013620000038a (9 bytes) 18:28:56.848 SERIAL » [ACK] (0x06) 18:28:56.849 SERIAL The receive buffer is empty, waiting for the next chunk... 18:28:56.849 DRIVER ACK received from node for current transaction. RTT = 4762.82 ms 18:29:02.083 DRIVER The awake timeout for node 4 has elapsed. Assuming it is asleep. 18:29:02.084 CNTRLR [Node 004] The node is now asleep. 18:29:02.090 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:29:02.090 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:29:30.155 SERIAL « 0x01 (1 bytes) 18:29:30.155 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:29:30.158 CNTRLR [Node 006] [~] [Battery] level: 80 => 80 [Endpoint 0] 18:29:30.157 SERIAL « 0x09000400060380035024 (10 bytes) 18:29:30.157 SERIAL Buffer := 0x0109000400060380035024 (11 bytes) 18:29:30.162 SERIAL » [ACK] (0x06) 18:29:30.162 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:30.160 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 0] 18:29:30.180 SERIAL « 0x01 (1 bytes) 18:29:30.180 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:29:30.183 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpoint[1]: 4 => 4 [Endpoint 0] 18:29:30.181 SERIAL « 0x0c000400060643030142019065 (13 bytes) 18:29:30.181 SERIAL Buffer := 0x010c000400060643030142019065 (14 bytes) 18:29:30.185 SERIAL » [ACK] (0x06) 18:29:30.186 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:30.200 SERIAL « 0x01 (1 bytes) 18:29:30.200 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:29:30.205 SERIAL « 0x0a00040006044608007fc2 (11 bytes) 18:29:30.208 CNTRLR [Node 006] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:29:30.206 SERIAL Buffer := 0x010a00040006044608007fc2 (12 bytes) 18:29:30.213 SERIAL » [ACK] (0x06) 18:29:30.214 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:30.211 CNTRLR [Node 006] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:29:30.218 SERIAL « 0x01 (1 bytes) 18:29:30.219 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:29:30.222 CNTRLR « [Node 006] received wakeup notification 18:29:30.225 DRIVER » [Node 006] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:29:30.221 SERIAL « 0x080004000602840774 (9 bytes) 18:29:30.221 SERIAL Buffer := 0x01080004000602840774 (10 bytes) 18:29:30.222 SERIAL » [ACK] (0x06) 18:29:30.224 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:30.226 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:29:30.223 CNTRLR [Node 006] The node is now awake. 18:29:30.231 SERIAL « [ACK] (0x06) 18:29:30.231 DRIVER Unexpected ACK received 18:29:30.233 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:30.236 SERIAL « 0x01 (1 bytes) 18:29:30.238 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:29:30.243 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:29:30.240 SERIAL « 0x04011301e8 (5 bytes) 18:29:30.241 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:29:30.242 SERIAL » [ACK] (0x06) 18:29:30.245 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:30.254 SERIAL « 0x01 (1 bytes) 18:29:30.255 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:29:30.257 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:29:30.256 SERIAL « 0x0700136e00000386 (8 bytes) 18:29:30.256 SERIAL Buffer := 0x010700136e00000386 (9 bytes) 18:29:30.256 SERIAL » [ACK] (0x06) 18:29:30.258 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:30.258 DRIVER ACK received from node for current transaction. RTT = 32.59 ms 18:29:31.291 CNTRLR [Node 006] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:29:31.791 DRIVER » [Node 006] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:29:31.792 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:29:31.797 SERIAL « [ACK] (0x06) 18:29:31.799 DRIVER ACK received from controller for current transaction 18:29:31.800 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:31.803 SERIAL « 0x0104 (2 bytes) 18:29:31.804 SERIAL [incomplete] Buffer := 0x0104 (2 bytes) 18:29:31.805 SERIAL « 0x011301e8 (4 bytes) 18:29:31.806 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:29:31.806 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:29:31.806 SERIAL » [ACK] (0x06) 18:29:31.807 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:31.821 SERIAL « 0x01 (1 bytes) 18:29:31.821 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:29:31.824 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:29:31.822 SERIAL « 0x0700136e00000287 (8 bytes) 18:29:31.822 SERIAL Buffer := 0x010700136e00000287 (9 bytes) 18:29:31.823 SERIAL » [ACK] (0x06) 18:29:31.825 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:31.824 DRIVER ACK received from node for current transaction. RTT = 1599.05 ms 18:29:33.988 SERIAL « 0x01 (1 bytes) 18:29:33.988 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:29:33.991 CNTRLR « [Node 004] Received updated node info 18:29:33.995 DRIVER workOffSendQueue > skipping because a transaction is pending 18:29:33.989 SERIAL « 0x160049840410040804804681728f75438684ef46818f11 (23 bytes) 18:29:33.990 SERIAL Buffer := 0x01160049840410040804804681728f75438684ef46818f11 (24 bytes) 18:29:33.990 SERIAL » [ACK] (0x06) 18:29:33.994 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:33.992 CNTRLR [Node 004] The node is now awake. 18:29:34.424 CNTRLR [Node 006] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:29:34.925 DRIVER » [Node 006] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:29:34.926 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:29:34.929 SERIAL « [ACK] (0x06) 18:29:34.930 DRIVER ACK received from controller for current transaction 18:29:34.930 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:34.936 SERIAL « 0x01 (1 bytes) 18:29:34.937 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:29:34.939 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:29:34.938 SERIAL « 0x04011301e8 (5 bytes) 18:29:34.938 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:29:34.938 SERIAL » [ACK] (0x06) 18:29:34.939 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:34.953 SERIAL « 0x01 (1 bytes) 18:29:34.953 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:29:34.957 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:29:34.955 SERIAL « 0x0700136e00000287 (8 bytes) 18:29:34.956 SERIAL Buffer := 0x010700136e00000287 (9 bytes) 18:29:34.956 SERIAL » [ACK] (0x06) 18:29:34.958 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:34.957 DRIVER ACK received from node for current transaction. RTT = 4732.34 ms 18:29:40.225 DRIVER The awake timeout for node 6 has elapsed. Assuming it is asleep. 18:29:40.225 CNTRLR [Node 006] The node is now asleep. 18:29:40.227 DRIVER » [Node 004] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:29:40.228 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:29:40.233 SERIAL « [ACK] (0x06) 18:29:40.233 DRIVER Unexpected ACK received 18:29:40.234 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:40.239 SERIAL « 0x01 (1 bytes) 18:29:40.240 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:29:40.242 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:29:40.241 SERIAL « 0x04011301e8 (5 bytes) 18:29:40.241 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:29:40.241 SERIAL » [ACK] (0x06) 18:29:40.242 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:40.257 SERIAL « 0x01 (1 bytes) 18:29:40.257 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:29:40.259 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:29:40.258 SERIAL « 0x070013620000028b (8 bytes) 18:29:40.258 SERIAL Buffer := 0x01070013620000028b (9 bytes) 18:29:40.259 SERIAL » [ACK] (0x06) 18:29:40.260 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:40.260 DRIVER ACK received from node for current transaction. RTT = 32.71 ms 18:29:40.690 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:29:41.191 DRIVER » [Node 004] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:29:41.192 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:29:41.195 SERIAL « [ACK] (0x06) 18:29:41.196 DRIVER ACK received from controller for current transaction 18:29:41.196 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:41.201 SERIAL « 0x0104 (2 bytes) 18:29:41.203 SERIAL [incomplete] Buffer := 0x0104 (2 bytes) 18:29:41.205 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:29:41.204 SERIAL « 0x011301e8 (4 bytes) 18:29:41.204 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:29:41.205 SERIAL » [ACK] (0x06) 18:29:41.207 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:41.219 SERIAL « 0x01 (1 bytes) 18:29:41.220 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:29:41.222 SERIAL « 0x070013620000028b (8 bytes) 18:29:41.223 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:29:41.222 SERIAL Buffer := 0x01070013620000028b (9 bytes) 18:29:41.223 SERIAL » [ACK] (0x06) 18:29:41.224 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:41.224 DRIVER ACK received from node for current transaction. RTT = 996.85 ms 18:29:43.221 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:29:43.721 DRIVER » [Node 004] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:29:43.722 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:29:43.725 SERIAL « [ACK] (0x06) 18:29:43.726 DRIVER ACK received from controller for current transaction 18:29:43.726 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:43.732 SERIAL « 0x01 (1 bytes) 18:29:43.732 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:29:43.734 SERIAL « 0x04011301e8 (5 bytes) 18:29:43.735 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:29:43.735 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:29:43.735 SERIAL » [ACK] (0x06) 18:29:43.737 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:43.749 SERIAL « 0x01 (1 bytes) 18:29:43.749 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:29:43.754 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:29:43.753 SERIAL « 0x070013620000028b (8 bytes) 18:29:43.753 SERIAL Buffer := 0x01070013620000028b (9 bytes) 18:29:43.753 SERIAL » [ACK] (0x06) 18:29:43.755 SERIAL The receive buffer is empty, waiting for the next chunk... 18:29:43.754 DRIVER ACK received from node for current transaction. RTT = 3527.42 ms 18:29:43.993 DRIVER The awake timeout for node 4 has elapsed. Assuming it is asleep. 18:29:43.994 CNTRLR [Node 004] The node is now asleep. 18:29:43.995 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:29:43.996 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:30:04.330 SERIAL « 0x01 (1 bytes) 18:30:04.331 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:04.332 SERIAL « 0x09000400030380033342 (10 bytes) 18:30:04.334 CNTRLR [Node 003] [~] [Battery] level: 51 => 51 [Endpoint 0] 18:30:04.333 SERIAL Buffer := 0x0109000400030380033342 (11 bytes) 18:30:04.338 SERIAL » [ACK] (0x06) 18:30:04.340 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:04.337 CNTRLR [Node 003] [~] [Battery] isLow: false => false [Endpoint 0] 18:30:04.352 SERIAL « 0x01 (1 bytes) 18:30:04.354 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:04.358 CNTRLR [Node 003] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:30:04.355 SERIAL « 0x0c0004000306430301420708fe (13 bytes) 18:30:04.355 SERIAL Buffer := 0x010c0004000306430301420708fe (14 bytes) 18:30:04.360 SERIAL » [ACK] (0x06) 18:30:04.361 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:04.372 SERIAL « 0x01 (1 bytes) 18:30:04.372 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:04.374 SERIAL « 0x0a00040003044608007fc7 (11 bytes) 18:30:04.377 CNTRLR [Node 003] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:30:04.374 SERIAL Buffer := 0x010a00040003044608007fc7 (12 bytes) 18:30:04.380 SERIAL » [ACK] (0x06) 18:30:04.381 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:04.379 CNTRLR [Node 003] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:30:04.394 SERIAL « 0x01 (1 bytes) 18:30:04.395 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:04.400 CNTRLR « [Node 003] received wakeup notification 18:30:04.406 DRIVER » [Node 003] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 122 └─[ThermostatSetpointCCGet] payload: 0x02 18:30:04.397 SERIAL « 0x080004000302840771 (9 bytes) 18:30:04.398 SERIAL Buffer := 0x01080004000302840771 (10 bytes) 18:30:04.399 SERIAL » [ACK] (0x06) 18:30:04.405 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:04.407 SERIAL » 0x010a00130303430202257afa (12 bytes) 18:30:04.403 CNTRLR [Node 003] The node is now awake. 18:30:04.418 SERIAL « [ACK] (0x06) 18:30:04.419 DRIVER Unexpected ACK received 18:30:04.419 SERIAL « 0x0601 (2 bytes) 18:30:04.420 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:04.423 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:30:04.422 SERIAL « 0x04011301e8 (5 bytes) 18:30:04.422 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:30:04.423 SERIAL » [ACK] (0x06) 18:30:04.424 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:04.436 SERIAL « 0x01 (1 bytes) 18:30:04.437 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:04.440 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 18:30:04.438 SERIAL « 0x0700137a00000392 (8 bytes) 18:30:04.439 SERIAL Buffer := 0x010700137a00000392 (9 bytes) 18:30:04.439 SERIAL » [ACK] (0x06) 18:30:04.441 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:04.440 DRIVER ACK received from node for current transaction. RTT = 34.66 ms 18:30:05.476 CNTRLR [Node 003] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:30:05.976 DRIVER » [Node 003] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 122 └─[ThermostatSetpointCCGet] payload: 0x02 18:30:05.977 SERIAL » 0x010a00130303430202257afa (12 bytes) 18:30:05.981 SERIAL « [ACK] (0x06) 18:30:05.981 DRIVER ACK received from controller for current transaction 18:30:05.982 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:05.988 SERIAL « 0x01 (1 bytes) 18:30:05.988 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:05.990 SERIAL « 0x04011301e8 (5 bytes) 18:30:05.993 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:30:05.992 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:30:05.992 SERIAL » [ACK] (0x06) 18:30:05.993 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:06.004 SERIAL « 0x01 (1 bytes) 18:30:06.005 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:06.007 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 18:30:06.006 SERIAL « 0x0700137a00000392 (8 bytes) 18:30:06.006 SERIAL Buffer := 0x010700137a00000392 (9 bytes) 18:30:06.007 SERIAL » [ACK] (0x06) 18:30:06.008 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:06.008 DRIVER ACK received from node for current transaction. RTT = 1601.79 ms 18:30:06.407 SERIAL « 0x01 (1 bytes) 18:30:06.408 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:06.409 SERIAL « 0x160049840410040804804681728f75438684ef46818f11 (23 bytes) 18:30:06.411 CNTRLR « [Node 004] Received updated node info 18:30:06.414 DRIVER workOffSendQueue > skipping because a transaction is pending 18:30:06.410 SERIAL Buffer := 0x01160049840410040804804681728f75438684ef46818f11 (24 bytes) 18:30:06.410 SERIAL » [ACK] (0x06) 18:30:06.413 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:06.412 CNTRLR [Node 004] The node is now awake. 18:30:08.610 CNTRLR [Node 003] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:30:09.111 DRIVER » [Node 003] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 122 └─[ThermostatSetpointCCGet] payload: 0x02 18:30:09.111 SERIAL » 0x010a00130303430202257afa (12 bytes) 18:30:09.115 SERIAL « [ACK] (0x06) 18:30:09.116 DRIVER ACK received from controller for current transaction 18:30:09.117 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:09.122 SERIAL « 0x01 (1 bytes) 18:30:09.124 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:09.129 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:30:09.125 SERIAL « 0x04011301e8 (5 bytes) 18:30:09.127 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:30:09.128 SERIAL » [ACK] (0x06) 18:30:09.129 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:09.139 SERIAL « 0x01 (1 bytes) 18:30:09.140 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:09.143 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 18:30:09.142 SERIAL « 0x0700137a00000293 (8 bytes) 18:30:09.142 SERIAL Buffer := 0x010700137a00000293 (9 bytes) 18:30:09.142 SERIAL » [ACK] (0x06) 18:30:09.144 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:09.144 DRIVER ACK received from node for current transaction. RTT = 4737.96 ms 18:30:14.404 DRIVER The awake timeout for node 3 has elapsed. Assuming it is asleep. 18:30:14.404 CNTRLR [Node 003] The node is now asleep. 18:30:14.406 DRIVER » [Node 004] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:30:14.407 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:30:14.410 SERIAL « [ACK] (0x06) 18:30:14.411 DRIVER Unexpected ACK received 18:30:14.412 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:14.418 SERIAL « 0x01 (1 bytes) 18:30:14.419 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:14.422 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:30:14.420 SERIAL « 0x04011301e8 (5 bytes) 18:30:14.421 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:30:14.421 SERIAL » [ACK] (0x06) 18:30:14.422 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:14.433 SERIAL « 0x01 (1 bytes) 18:30:14.434 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:14.436 SERIAL « 0x070013620000038a (8 bytes) 18:30:14.438 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:30:14.436 SERIAL Buffer := 0x01070013620000038a (9 bytes) 18:30:14.437 SERIAL » [ACK] (0x06) 18:30:14.443 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:14.438 DRIVER ACK received from node for current transaction. RTT = 32.39 ms 18:30:14.883 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:30:15.385 DRIVER » [Node 004] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:30:15.386 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:30:15.391 SERIAL « [ACK] (0x06) 18:30:15.392 DRIVER ACK received from controller for current transaction 18:30:15.393 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:15.398 SERIAL « 0x01 (1 bytes) 18:30:15.399 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:15.402 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:30:15.400 SERIAL « 0x04011301e8 (5 bytes) 18:30:15.401 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:30:15.401 SERIAL » [ACK] (0x06) 18:30:15.402 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:15.415 SERIAL « 0x01 (1 bytes) 18:30:15.416 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:15.418 SERIAL « 0x070013620000038a (8 bytes) 18:30:15.426 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:30:15.420 SERIAL Buffer := 0x01070013620000038a (9 bytes) 18:30:15.424 SERIAL » [ACK] (0x06) 18:30:15.428 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:15.426 DRIVER ACK received from node for current transaction. RTT = 1020.60 ms 18:30:16.414 DRIVER The awake timeout for node 4 has elapsed. Assuming it is asleep. 18:30:16.414 CNTRLR [Node 004] The node is now asleep. 18:30:16.416 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:30:16.417 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:30:27.940 SERIAL « 0x01 (1 bytes) 18:30:27.941 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:27.943 CNTRLR « [Node 004] Received updated node info 18:30:27.942 SERIAL « 0x160049840410040804804681728f75438684ef46818f11 (23 bytes) 18:30:27.942 SERIAL Buffer := 0x01160049840410040804804681728f75438684ef46818f11 (24 bytes) 18:30:27.943 SERIAL » [ACK] (0x06) 18:30:27.946 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:27.947 DRIVER » [Node 004] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:30:27.945 CNTRLR [Node 004] The node is now awake. 18:30:27.948 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:30:27.952 SERIAL « [ACK] (0x06) 18:30:27.953 DRIVER Unexpected ACK received 18:30:27.957 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:27.962 SERIAL « 0x01 (1 bytes) 18:30:27.962 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:27.964 SERIAL « 0x04011301e8 (5 bytes) 18:30:27.966 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:30:27.964 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:30:27.965 SERIAL » [ACK] (0x06) 18:30:27.966 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:27.976 SERIAL « 0x01 (1 bytes) 18:30:27.976 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:27.978 SERIAL « 0x070013620000028b (8 bytes) 18:30:27.979 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:30:27.978 SERIAL Buffer := 0x01070013620000028b (9 bytes) 18:30:27.978 SERIAL » [ACK] (0x06) 18:30:27.980 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:27.979 DRIVER ACK received from node for current transaction. RTT = 32.12 ms 18:30:29.012 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:30:29.513 DRIVER » [Node 004] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:30:29.514 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:30:29.518 SERIAL « [ACK] (0x06) 18:30:29.518 DRIVER ACK received from controller for current transaction 18:30:29.518 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:29.524 SERIAL « 0x01 (1 bytes) 18:30:29.525 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:29.526 SERIAL « 0x04011301e8 (5 bytes) 18:30:29.528 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:30:29.527 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:30:29.527 SERIAL » [ACK] (0x06) 18:30:29.528 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:29.541 SERIAL « 0x01 (1 bytes) 18:30:29.542 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:29.544 SERIAL « 0x070013620000028b (8 bytes) 18:30:29.545 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:30:29.544 SERIAL Buffer := 0x01070013620000028b (9 bytes) 18:30:29.544 SERIAL » [ACK] (0x06) 18:30:29.546 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:29.545 DRIVER ACK received from node for current transaction. RTT = 1598.33 ms 18:30:32.144 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:30:32.645 DRIVER » [Node 004] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:30:32.646 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:30:32.650 SERIAL « [ACK] (0x06) 18:30:32.650 DRIVER ACK received from controller for current transaction 18:30:32.650 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:32.656 SERIAL « 0x01 (1 bytes) 18:30:32.657 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:32.660 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:30:32.659 SERIAL « 0x04011301e8 (5 bytes) 18:30:32.659 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:30:32.659 SERIAL » [ACK] (0x06) 18:30:32.660 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:32.673 SERIAL « 0x01 (1 bytes) 18:30:32.673 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:32.675 SERIAL « 0x070013620000038a (8 bytes) 18:30:32.676 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:30:32.675 SERIAL Buffer := 0x01070013620000038a (9 bytes) 18:30:32.676 SERIAL » [ACK] (0x06) 18:30:32.677 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:32.677 DRIVER ACK received from node for current transaction. RTT = 4729.56 ms 18:30:37.947 DRIVER The awake timeout for node 4 has elapsed. Assuming it is asleep. 18:30:37.947 CNTRLR [Node 004] The node is now asleep. 18:30:37.949 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:30:37.950 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:30:54.346 SERIAL « 0x01 (1 bytes) 18:30:54.349 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:54.352 CNTRLR [Node 008] [~] [Battery] level: 72 => 72 [Endpoint 0] 18:30:54.350 SERIAL « 0x09000400080380034832 (10 bytes) 18:30:54.351 SERIAL Buffer := 0x0109000400080380034832 (11 bytes) 18:30:54.355 SERIAL » [ACK] (0x06) 18:30:54.355 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:54.353 CNTRLR [Node 008] [~] [Battery] isLow: false => false [Endpoint 0] 18:30:54.367 SERIAL « 0x01 (1 bytes) 18:30:54.368 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:54.370 SERIAL « 0x0c00040008064303014201c239 (13 bytes) 18:30:54.372 CNTRLR [Node 008] [~] [Thermostat Setpoint] setpoint[1]: 4.5 => 4.5 [Endpoint 0] 18:30:54.371 SERIAL Buffer := 0x010c00040008064303014201c239 (14 bytes) 18:30:54.374 SERIAL » [ACK] (0x06) 18:30:54.374 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:54.387 SERIAL « 0x01 (1 bytes) 18:30:54.388 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:54.389 SERIAL « 0x0a00040008044608007fcc (11 bytes) 18:30:54.390 CNTRLR [Node 008] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:30:54.392 CNTRLR [Node 008] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:30:54.389 SERIAL Buffer := 0x010a00040008044608007fcc (12 bytes) 18:30:54.393 SERIAL » [ACK] (0x06) 18:30:54.394 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:54.409 SERIAL « 0x01 (1 bytes) 18:30:54.410 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:54.412 SERIAL « 0x0c000400080631050142079f16 (13 bytes) 18:30:54.414 CNTRLR [Node 008] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 18:30:54.412 SERIAL Buffer := 0x010c000400080631050142079f16 (14 bytes) 18:30:54.417 SERIAL » [ACK] (0x06) 18:30:54.418 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:54.416 CNTRLR [Node 008] [~] [Multilevel Sensor] Air temperature: 19.5 => 19.51 [Endpoint 0] 18:30:54.430 SERIAL « 0x01 (1 bytes) 18:30:54.431 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:54.433 CNTRLR « [Node 008] received wakeup notification 18:30:54.436 DRIVER » [Node 008] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:30:54.432 SERIAL « 0x08000400080284077a (9 bytes) 18:30:54.432 SERIAL Buffer := 0x0108000400080284077a (10 bytes) 18:30:54.432 SERIAL » [ACK] (0x06) 18:30:54.435 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:54.436 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:30:54.433 CNTRLR [Node 008] The node is now awake. 18:30:54.440 SERIAL « [ACK] (0x06) 18:30:54.441 DRIVER Unexpected ACK received 18:30:54.441 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:54.447 SERIAL « 0x01 (1 bytes) 18:30:54.448 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:54.449 SERIAL « 0x04011301e8 (5 bytes) 18:30:54.450 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:30:54.449 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:30:54.450 SERIAL » [ACK] (0x06) 18:30:54.451 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:54.464 SERIAL « 0x01 (1 bytes) 18:30:54.465 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:54.468 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:30:54.466 SERIAL « 0x0700138a00000362 (8 bytes) 18:30:54.467 SERIAL Buffer := 0x010700138a00000362 (9 bytes) 18:30:54.467 SERIAL » [ACK] (0x06) 18:30:54.469 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:54.468 DRIVER ACK received from node for current transaction. RTT = 32.50 ms 18:30:55.501 CNTRLR [Node 008] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:30:56.003 DRIVER » [Node 008] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:30:56.003 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:30:56.007 SERIAL « [ACK] (0x06) 18:30:56.008 DRIVER ACK received from controller for current transaction 18:30:56.008 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:56.014 SERIAL « 0x01 (1 bytes) 18:30:56.014 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:56.016 SERIAL « 0x04011301e8 (5 bytes) 18:30:56.017 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:30:56.016 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:30:56.017 SERIAL » [ACK] (0x06) 18:30:56.017 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:56.031 SERIAL « 0x01 (1 bytes) 18:30:56.031 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:56.033 SERIAL « 0x0700138a00000263 (8 bytes) 18:30:56.034 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:30:56.033 SERIAL Buffer := 0x010700138a00000263 (9 bytes) 18:30:56.034 SERIAL » [ACK] (0x06) 18:30:56.035 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:56.034 DRIVER ACK received from node for current transaction. RTT = 1598.89 ms 18:30:58.633 CNTRLR [Node 008] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:30:59.135 DRIVER » [Node 008] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:30:59.135 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:30:59.139 SERIAL « [ACK] (0x06) 18:30:59.139 DRIVER ACK received from controller for current transaction 18:30:59.140 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:59.146 SERIAL « 0x01 (1 bytes) 18:30:59.146 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:59.148 SERIAL « 0x04011301e8 (5 bytes) 18:30:59.149 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:30:59.148 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:30:59.149 SERIAL » [ACK] (0x06) 18:30:59.150 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:59.163 SERIAL « 0x01 (1 bytes) 18:30:59.163 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:30:59.165 SERIAL « 0x0700138a00000263 (8 bytes) 18:30:59.166 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:30:59.165 SERIAL Buffer := 0x010700138a00000263 (9 bytes) 18:30:59.166 SERIAL » [ACK] (0x06) 18:30:59.168 SERIAL The receive buffer is empty, waiting for the next chunk... 18:30:59.167 DRIVER ACK received from node for current transaction. RTT = 4731.40 ms 18:31:04.435 DRIVER The awake timeout for node 8 has elapsed. Assuming it is asleep. 18:31:04.435 CNTRLR [Node 008] The node is now asleep. 18:31:04.437 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:31:04.438 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:31:56.305 SERIAL « 0x01 (1 bytes) 18:31:56.306 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:31:56.307 SERIAL « 0x09000400020380035020 (10 bytes) 18:31:56.309 CNTRLR [Node 002] [~] [Battery] level: 80 => 80 [Endpoint 0] 18:31:56.308 SERIAL Buffer := 0x0109000400020380035020 (11 bytes) 18:31:56.312 SERIAL » [ACK] (0x06) 18:31:56.313 SERIAL The receive buffer is empty, waiting for the next chunk... 18:31:56.311 CNTRLR [Node 002] [~] [Battery] isLow: false => false [Endpoint 0] 18:31:56.327 SERIAL « 0x01 (1 bytes) 18:31:56.328 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:31:56.332 SERIAL « 0x0c0004000206430301420708ff (13 bytes) 18:31:56.333 CNTRLR [Node 002] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:31:56.332 SERIAL Buffer := 0x010c0004000206430301420708ff (14 bytes) 18:31:56.335 SERIAL » [ACK] (0x06) 18:31:56.336 SERIAL The receive buffer is empty, waiting for the next chunk... 18:31:56.347 SERIAL « 0x01 (1 bytes) 18:31:56.347 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:31:56.349 SERIAL « 0x0a00040002044608007fc6 (11 bytes) 18:31:56.351 CNTRLR [Node 002] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:31:56.350 SERIAL Buffer := 0x010a00040002044608007fc6 (12 bytes) 18:31:56.354 SERIAL » [ACK] (0x06) 18:31:56.355 SERIAL The receive buffer is empty, waiting for the next chunk... 18:31:56.353 CNTRLR [Node 002] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:31:56.371 SERIAL « 0x01080004000202840770 (10 bytes) 18:31:56.372 CNTRLR « [Node 002] received wakeup notification 18:31:56.378 DRIVER » [Node 002] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:31:56.371 SERIAL Buffer := 0x01080004000202840770 (10 bytes) 18:31:56.372 SERIAL » [ACK] (0x06) 18:31:56.375 SERIAL The receive buffer is empty, waiting for the next chunk... 18:31:56.378 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:31:56.373 CNTRLR [Node 002] The node is now awake. 18:31:56.383 SERIAL « [ACK] (0x06) 18:31:56.383 DRIVER Unexpected ACK received 18:31:56.383 SERIAL The receive buffer is empty, waiting for the next chunk... 18:31:56.389 SERIAL « 0x01 (1 bytes) 18:31:56.389 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:31:56.390 SERIAL « 0x04011301e8 (5 bytes) 18:31:56.392 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:31:56.391 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:31:56.391 SERIAL » [ACK] (0x06) 18:31:56.392 SERIAL The receive buffer is empty, waiting for the next chunk... 18:31:56.407 SERIAL « 0x01 (1 bytes) 18:31:56.407 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:31:56.410 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:31:56.409 SERIAL « 0x0700134a000002a3 (8 bytes) 18:31:56.410 SERIAL Buffer := 0x010700134a000002a3 (9 bytes) 18:31:56.410 SERIAL » [ACK] (0x06) 18:31:56.411 SERIAL The receive buffer is empty, waiting for the next chunk... 18:31:56.411 DRIVER ACK received from node for current transaction. RTT = 35.17 ms 18:31:57.447 CNTRLR [Node 002] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:31:57.948 DRIVER » [Node 002] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:31:57.948 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:31:57.952 SERIAL « [ACK] (0x06) 18:31:57.953 DRIVER ACK received from controller for current transaction 18:31:57.953 SERIAL The receive buffer is empty, waiting for the next chunk... 18:31:57.958 SERIAL « 0x01 (1 bytes) 18:31:57.959 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:31:57.961 SERIAL « 0x04011301e8 (5 bytes) 18:31:57.962 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:31:57.961 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:31:57.961 SERIAL » [ACK] (0x06) 18:31:57.962 SERIAL The receive buffer is empty, waiting for the next chunk... 18:31:57.975 SERIAL « 0x01 (1 bytes) 18:31:57.976 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:31:57.978 SERIAL « 0x0700134a000003a2 (8 bytes) 18:31:57.979 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:31:57.978 SERIAL Buffer := 0x010700134a000003a2 (9 bytes) 18:31:57.978 SERIAL » [ACK] (0x06) 18:31:57.980 SERIAL The receive buffer is empty, waiting for the next chunk... 18:31:57.979 DRIVER ACK received from node for current transaction. RTT = 1603.86 ms 18:32:00.585 CNTRLR [Node 002] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:32:01.089 DRIVER » [Node 002] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:32:01.090 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:32:01.101 SERIAL « [ACK] (0x06) 18:32:01.105 DRIVER ACK received from controller for current transaction 18:32:01.107 SERIAL The receive buffer is empty, waiting for the next chunk... 18:32:01.111 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:32:01.108 SERIAL « 0x0104011301e8 (6 bytes) 18:32:01.110 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:32:01.111 SERIAL » [ACK] (0x06) 18:32:01.114 SERIAL The receive buffer is empty, waiting for the next chunk... 18:32:01.123 SERIAL « 0x010700134a000002a3 (9 bytes) 18:32:01.126 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:32:01.124 SERIAL Buffer := 0x010700134a000002a3 (9 bytes) 18:32:01.125 SERIAL » [ACK] (0x06) 18:32:01.130 SERIAL The receive buffer is empty, waiting for the next chunk... 18:32:01.129 DRIVER ACK received from node for current transaction. RTT = 4753.46 ms 18:32:06.374 DRIVER The awake timeout for node 2 has elapsed. Assuming it is asleep. 18:32:06.375 CNTRLR [Node 002] The node is now asleep. 18:32:06.377 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:32:06.378 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:33:20.680 SERIAL « 0x01 (1 bytes) 18:33:20.681 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:33:20.686 CNTRLR [Node 005] [~] [Battery] level: 58 => 58 [Endpoint 0] 18:33:20.683 SERIAL « 0x09000400050380033a4d (10 bytes) 18:33:20.684 SERIAL Buffer := 0x0109000400050380033a4d (11 bytes) 18:33:20.688 SERIAL » [ACK] (0x06) 18:33:20.689 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:20.687 CNTRLR [Node 005] [~] [Battery] isLow: false => false [Endpoint 0] 18:33:20.703 SERIAL « 0x01 (1 bytes) 18:33:20.703 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:33:20.706 SERIAL « 0x0c0004000506430301420708f8 (13 bytes) 18:33:20.709 CNTRLR [Node 005] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:33:20.707 SERIAL Buffer := 0x010c0004000506430301420708f8 (14 bytes) 18:33:20.711 SERIAL » [ACK] (0x06) 18:33:20.711 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:20.723 SERIAL « 0x01 (1 bytes) 18:33:20.723 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:33:20.725 CNTRLR [Node 005] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:33:20.724 SERIAL « 0x0a00040005044608007fc1 (11 bytes) 18:33:20.724 SERIAL Buffer := 0x010a00040005044608007fc1 (12 bytes) 18:33:20.729 SERIAL » [ACK] (0x06) 18:33:20.729 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:20.727 CNTRLR [Node 005] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:33:20.744 SERIAL « 0x01 (1 bytes) 18:33:20.744 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:33:20.748 CNTRLR « [Node 005] received wakeup notification 18:33:20.746 SERIAL « 0x080004000502840777 (9 bytes) 18:33:20.746 SERIAL Buffer := 0x01080004000502840777 (10 bytes) 18:33:20.747 SERIAL » [ACK] (0x06) 18:33:20.753 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:20.757 DRIVER » [Node 005] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:33:20.749 CNTRLR [Node 005] The node is now awake. 18:33:20.757 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:33:20.764 SERIAL « [ACK] (0x06) 18:33:20.765 DRIVER Unexpected ACK received 18:33:20.765 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:20.769 SERIAL « 0x01 (1 bytes) 18:33:20.769 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:33:20.771 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:33:20.770 SERIAL « 0x04011301e8 (5 bytes) 18:33:20.770 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:33:20.770 SERIAL » [ACK] (0x06) 18:33:20.772 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:20.785 SERIAL « 0x01 (1 bytes) 18:33:20.785 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:33:20.787 SERIAL « 0x07001356000003be (8 bytes) 18:33:20.788 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:33:20.787 SERIAL Buffer := 0x0107001356000003be (9 bytes) 18:33:20.788 SERIAL » [ACK] (0x06) 18:33:20.789 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:20.788 DRIVER ACK received from node for current transaction. RTT = 32.39 ms 18:33:21.821 CNTRLR [Node 005] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:33:22.322 DRIVER » [Node 005] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:33:22.323 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:33:22.329 SERIAL « [ACK] (0x06) 18:33:22.329 DRIVER ACK received from controller for current transaction 18:33:22.330 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:22.334 SERIAL « 0x01 (1 bytes) 18:33:22.335 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:33:22.338 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:33:22.337 SERIAL « 0x04011301e8 (5 bytes) 18:33:22.337 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:33:22.337 SERIAL » [ACK] (0x06) 18:33:22.338 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:22.351 SERIAL « 0x01 (1 bytes) 18:33:22.351 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:33:22.354 SERIAL « 0x07001356000002bf (8 bytes) 18:33:22.355 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:33:22.354 SERIAL Buffer := 0x0107001356000002bf (9 bytes) 18:33:22.354 SERIAL » [ACK] (0x06) 18:33:22.356 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:22.356 DRIVER ACK received from node for current transaction. RTT = 1599.81 ms 18:33:24.957 CNTRLR [Node 005] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:33:25.457 DRIVER » [Node 005] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:33:25.458 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:33:25.461 SERIAL « [ACK] (0x06) 18:33:25.462 DRIVER ACK received from controller for current transaction 18:33:25.462 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:25.468 SERIAL « 0x01 (1 bytes) 18:33:25.468 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:33:25.471 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:33:25.470 SERIAL « 0x04011301e8 (5 bytes) 18:33:25.470 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:33:25.470 SERIAL » [ACK] (0x06) 18:33:25.473 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:25.485 SERIAL « 0x01 (1 bytes) 18:33:25.486 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:33:25.487 SERIAL « 0x07001356000003be (8 bytes) 18:33:25.489 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:33:25.488 SERIAL Buffer := 0x0107001356000003be (9 bytes) 18:33:25.488 SERIAL » [ACK] (0x06) 18:33:25.490 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:25.489 DRIVER ACK received from node for current transaction. RTT = 4732.98 ms 18:33:30.750 DRIVER The awake timeout for node 5 has elapsed. Assuming it is asleep. 18:33:30.751 CNTRLR [Node 005] The node is now asleep. 18:33:30.753 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:33:30.753 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:33:50.263 SERIAL « 0x01 (1 bytes) 18:33:50.263 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:33:50.266 CNTRLR [Node 004] [~] [Battery] level: 40 => 40 [Endpoint 0] 18:33:50.264 SERIAL « 0x0900040004038003285e (10 bytes) 18:33:50.265 SERIAL Buffer := 0x010900040004038003285e (11 bytes) 18:33:50.269 SERIAL » [ACK] (0x06) 18:33:50.269 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:50.268 CNTRLR [Node 004] [~] [Battery] isLow: false => false [Endpoint 0] 18:33:50.287 SERIAL « 0x01 (1 bytes) 18:33:50.287 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:33:50.290 CNTRLR [Node 004] [~] [Thermostat Setpoint] setpoint[1]: 5 => 5 [Endpoint 0] 18:33:50.288 SERIAL « 0x0c00040004064303014201f403 (13 bytes) 18:33:50.289 SERIAL Buffer := 0x010c00040004064303014201f403 (14 bytes) 18:33:50.291 SERIAL » [ACK] (0x06) 18:33:50.292 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:50.305 SERIAL « 0x01 (1 bytes) 18:33:50.306 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:33:50.307 SERIAL « 0x0a00040004044608007fc0 (11 bytes) 18:33:50.309 CNTRLR [Node 004] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:33:50.308 SERIAL Buffer := 0x010a00040004044608007fc0 (12 bytes) 18:33:50.312 SERIAL » [ACK] (0x06) 18:33:50.313 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:50.311 CNTRLR [Node 004] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:33:50.325 SERIAL « 0x01 (1 bytes) 18:33:50.325 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:33:50.328 SERIAL « 0x080004000402840776 (9 bytes) 18:33:50.330 CNTRLR « [Node 004] received wakeup notification 18:33:50.333 DRIVER » [Node 004] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:33:50.329 SERIAL Buffer := 0x01080004000402840776 (10 bytes) 18:33:50.329 SERIAL » [ACK] (0x06) 18:33:50.332 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:50.335 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:33:50.331 CNTRLR [Node 004] The node is now awake. 18:33:50.339 SERIAL « [ACK] (0x06) 18:33:50.340 DRIVER Unexpected ACK received 18:33:50.340 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:50.345 SERIAL « 0x01 (1 bytes) 18:33:50.346 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:33:50.348 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:33:50.347 SERIAL « 0x04011301e8 (5 bytes) 18:33:50.347 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:33:50.348 SERIAL » [ACK] (0x06) 18:33:50.349 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:50.361 SERIAL « 0x01 (1 bytes) 18:33:50.362 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:33:50.364 SERIAL « 0x070013620000028b (8 bytes) 18:33:50.365 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:33:50.364 SERIAL Buffer := 0x01070013620000028b (9 bytes) 18:33:50.364 SERIAL » [ACK] (0x06) 18:33:50.367 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:50.365 DRIVER ACK received from node for current transaction. RTT = 32.52 ms 18:33:51.398 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:33:51.899 DRIVER » [Node 004] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:33:51.900 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:33:51.904 SERIAL « [ACK] (0x06) 18:33:51.904 DRIVER ACK received from controller for current transaction 18:33:51.905 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:51.911 SERIAL « 0x01 (1 bytes) 18:33:51.911 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:33:51.913 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:33:51.912 SERIAL « 0x04011301e8 (5 bytes) 18:33:51.912 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:33:51.913 SERIAL » [ACK] (0x06) 18:33:51.913 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:51.927 SERIAL « 0x01 (1 bytes) 18:33:51.928 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:33:51.930 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:33:51.929 SERIAL « 0x070013620000028b (8 bytes) 18:33:51.929 SERIAL Buffer := 0x01070013620000028b (9 bytes) 18:33:51.929 SERIAL » [ACK] (0x06) 18:33:51.931 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:51.930 DRIVER ACK received from node for current transaction. RTT = 1597.58 ms 18:33:54.528 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:33:55.029 DRIVER » [Node 004] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:33:55.029 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:33:55.035 SERIAL « [ACK] (0x06) 18:33:55.035 DRIVER ACK received from controller for current transaction 18:33:55.036 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:55.040 SERIAL « 0x01 (1 bytes) 18:33:55.040 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:33:55.042 SERIAL « 0x04011301e8 (5 bytes) 18:33:55.044 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:33:55.043 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:33:55.043 SERIAL » [ACK] (0x06) 18:33:55.044 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:55.057 SERIAL « 0x01 (1 bytes) 18:33:55.058 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:33:55.060 SERIAL « 0x070013620000028b (8 bytes) 18:33:55.061 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:33:55.060 SERIAL Buffer := 0x01070013620000028b (9 bytes) 18:33:55.060 SERIAL » [ACK] (0x06) 18:33:55.062 SERIAL The receive buffer is empty, waiting for the next chunk... 18:33:55.061 DRIVER ACK received from node for current transaction. RTT = 4728.47 ms 18:34:00.331 DRIVER The awake timeout for node 4 has elapsed. Assuming it is asleep. 18:34:00.332 CNTRLR [Node 004] The node is now asleep. 18:34:00.338 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:34:00.339 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:34:20.827 SERIAL « 0x01 (1 bytes) 18:34:20.828 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:34:20.830 CNTRLR [Node 006] [~] [Battery] level: 80 => 80 [Endpoint 0] 18:34:20.829 SERIAL « 0x09000400060380035024 (10 bytes) 18:34:20.829 SERIAL Buffer := 0x0109000400060380035024 (11 bytes) 18:34:20.833 SERIAL » [ACK] (0x06) 18:34:20.834 SERIAL The receive buffer is empty, waiting for the next chunk... 18:34:20.832 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 0] 18:34:20.854 SERIAL « 0x010c000400060643030142019065 (14 bytes) 18:34:20.856 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpoint[1]: 4 => 4 [Endpoint 0] 18:34:20.854 SERIAL Buffer := 0x010c000400060643030142019065 (14 bytes) 18:34:20.857 SERIAL » [ACK] (0x06) 18:34:20.858 SERIAL The receive buffer is empty, waiting for the next chunk... 18:34:20.868 SERIAL « 0x01 (1 bytes) 18:34:20.868 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:34:20.870 SERIAL « 0x0a00040006044608007fc2 (11 bytes) 18:34:20.872 CNTRLR [Node 006] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:34:20.871 SERIAL Buffer := 0x010a00040006044608007fc2 (12 bytes) 18:34:20.876 SERIAL » [ACK] (0x06) 18:34:20.876 SERIAL The receive buffer is empty, waiting for the next chunk... 18:34:20.874 CNTRLR [Node 006] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:34:20.888 SERIAL « 0x01 (1 bytes) 18:34:20.889 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:34:20.892 SERIAL « 0x080004000602840774 (9 bytes) 18:34:20.894 CNTRLR « [Node 006] received wakeup notification 18:34:20.898 DRIVER » [Node 006] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:34:20.893 SERIAL Buffer := 0x01080004000602840774 (10 bytes) 18:34:20.893 SERIAL » [ACK] (0x06) 18:34:20.897 SERIAL The receive buffer is empty, waiting for the next chunk... 18:34:20.899 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:34:20.894 CNTRLR [Node 006] The node is now awake. 18:34:20.905 SERIAL « [ACK] (0x06) 18:34:20.905 DRIVER Unexpected ACK received 18:34:20.906 SERIAL The receive buffer is empty, waiting for the next chunk... 18:34:20.910 SERIAL « 0x01 (1 bytes) 18:34:20.910 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:34:20.912 SERIAL « 0x04011301e8 (5 bytes) 18:34:20.913 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:34:20.912 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:34:20.913 SERIAL » [ACK] (0x06) 18:34:20.913 SERIAL The receive buffer is empty, waiting for the next chunk... 18:34:20.928 SERIAL « 0x01 (1 bytes) 18:34:20.928 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:34:20.930 SERIAL « 0x0700136e00000287 (8 bytes) 18:34:20.931 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:34:20.930 SERIAL Buffer := 0x010700136e00000287 (9 bytes) 18:34:20.931 SERIAL » [ACK] (0x06) 18:34:20.932 SERIAL The receive buffer is empty, waiting for the next chunk... 18:34:20.932 DRIVER ACK received from node for current transaction. RTT = 33.98 ms 18:34:21.967 CNTRLR [Node 006] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:34:22.469 DRIVER » [Node 006] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:34:22.471 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:34:22.475 SERIAL « [ACK] (0x06) 18:34:22.475 DRIVER ACK received from controller for current transaction 18:34:22.476 SERIAL The receive buffer is empty, waiting for the next chunk... 18:34:22.481 SERIAL « 0x01 (1 bytes) 18:34:22.481 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:34:22.483 SERIAL « 0x04011301e8 (5 bytes) 18:34:22.484 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:34:22.483 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:34:22.484 SERIAL » [ACK] (0x06) 18:34:22.484 SERIAL The receive buffer is empty, waiting for the next chunk... 18:34:22.498 SERIAL « 0x01 (1 bytes) 18:34:22.498 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:34:22.500 SERIAL « 0x0700136e00000287 (8 bytes) 18:34:22.501 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:34:22.502 DRIVER ACK received from node for current transaction. RTT = 1604.03 ms 18:34:22.501 SERIAL Buffer := 0x010700136e00000287 (9 bytes) 18:34:22.501 SERIAL » [ACK] (0x06) 18:34:22.504 SERIAL The receive buffer is empty, waiting for the next chunk... 18:34:25.108 CNTRLR [Node 006] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:34:25.608 DRIVER » [Node 006] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:34:25.609 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:34:25.612 SERIAL « [ACK] (0x06) 18:34:25.614 DRIVER ACK received from controller for current transaction 18:34:25.615 SERIAL The receive buffer is empty, waiting for the next chunk... 18:34:25.619 SERIAL « 0x01 (1 bytes) 18:34:25.619 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:34:25.622 SERIAL « 0x04011301e8 (5 bytes) 18:34:25.623 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:34:25.622 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:34:25.623 SERIAL » [ACK] (0x06) 18:34:25.624 SERIAL The receive buffer is empty, waiting for the next chunk... 18:34:25.637 SERIAL « 0x01 (1 bytes) 18:34:25.638 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:34:25.640 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:34:25.638 SERIAL « 0x0700136e00000287 (8 bytes) 18:34:25.639 SERIAL Buffer := 0x010700136e00000287 (9 bytes) 18:34:25.639 SERIAL » [ACK] (0x06) 18:34:25.641 SERIAL The receive buffer is empty, waiting for the next chunk... 18:34:25.640 DRIVER ACK received from node for current transaction. RTT = 4742.42 ms 18:34:30.895 DRIVER The awake timeout for node 6 has elapsed. Assuming it is asleep. 18:34:30.896 CNTRLR [Node 006] The node is now asleep. 18:34:30.899 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:34:30.899 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:35:00.355 SERIAL « 0x01 (1 bytes) 18:35:00.356 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:35:00.375 CNTRLR [Node 003] [~] [Battery] level: 51 => 51 [Endpoint 0] 18:35:00.362 SERIAL « 0x09000400030380033342 (10 bytes) 18:35:00.363 SERIAL Buffer := 0x0109000400030380033342 (11 bytes) 18:35:00.390 SERIAL » [ACK] (0x06) 18:35:00.397 SERIAL The receive buffer is empty, waiting for the next chunk... 18:35:00.384 CNTRLR [Node 003] [~] [Battery] isLow: false => false [Endpoint 0] 18:35:00.405 SERIAL « 0x01 (1 bytes) 18:35:00.406 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:35:00.417 CNTRLR [Node 003] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:35:00.407 SERIAL « 0x0c0004000306430301420708fe (13 bytes) 18:35:00.408 SERIAL Buffer := 0x010c0004000306430301420708fe (14 bytes) 18:35:00.419 SERIAL » [ACK] (0x06) 18:35:00.420 SERIAL The receive buffer is empty, waiting for the next chunk... 18:35:00.439 SERIAL « 0x010a00040003044608007fc7 (12 bytes) 18:35:00.458 CNTRLR [Node 003] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:35:00.440 SERIAL Buffer := 0x010a00040003044608007fc7 (12 bytes) 18:35:00.468 SERIAL » [ACK] (0x06) 18:35:00.469 SERIAL The receive buffer is empty, waiting for the next chunk... 18:35:00.467 CNTRLR [Node 003] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:35:48.645 SERIAL « 0x01 (1 bytes) 18:35:48.646 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:35:48.647 SERIAL « 0x09000400080380034832 (10 bytes) 18:35:48.649 CNTRLR [Node 008] [~] [Battery] level: 72 => 72 [Endpoint 0] 18:35:48.648 SERIAL Buffer := 0x0109000400080380034832 (11 bytes) 18:35:48.652 SERIAL » [ACK] (0x06) 18:35:48.653 SERIAL The receive buffer is empty, waiting for the next chunk... 18:35:48.651 CNTRLR [Node 008] [~] [Battery] isLow: false => false [Endpoint 0] 18:35:48.667 SERIAL « 0x01 (1 bytes) 18:35:48.667 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:35:48.671 SERIAL « 0x0c00040008064303014201c239 (13 bytes) 18:35:48.672 CNTRLR [Node 008] [~] [Thermostat Setpoint] setpoint[1]: 4.5 => 4.5 [Endpoint 0] 18:35:48.671 SERIAL Buffer := 0x010c00040008064303014201c239 (14 bytes) 18:35:48.674 SERIAL » [ACK] (0x06) 18:35:48.674 SERIAL The receive buffer is empty, waiting for the next chunk... 18:35:48.687 SERIAL « 0x01 (1 bytes) 18:35:48.688 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:35:48.690 CNTRLR [Node 008] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:35:48.689 SERIAL « 0x0a00040008044608007fcc (11 bytes) 18:35:48.689 SERIAL Buffer := 0x010a00040008044608007fcc (12 bytes) 18:35:48.694 SERIAL » [ACK] (0x06) 18:35:48.694 SERIAL The receive buffer is empty, waiting for the next chunk... 18:35:48.692 CNTRLR [Node 008] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:35:48.707 SERIAL « 0x01 (1 bytes) 18:35:48.708 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:35:48.712 SERIAL « 0x0c000400080631050142079d14 (13 bytes) 18:35:48.715 CNTRLR [Node 008] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 18:35:48.713 SERIAL Buffer := 0x010c000400080631050142079d14 (14 bytes) 18:35:48.718 SERIAL » [ACK] (0x06) 18:35:48.719 SERIAL The receive buffer is empty, waiting for the next chunk... 18:35:48.717 CNTRLR [Node 008] [~] [Multilevel Sensor] Air temperature: 19.51 => 19.4 [Endpoint 0] 9 18:35:48.733 SERIAL « 0x01 (1 bytes) 18:35:48.733 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:35:48.738 CNTRLR « [Node 008] received wakeup notification 18:35:48.744 DRIVER » [Node 008] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:35:48.735 SERIAL « 0x08000400080284077a (9 bytes) 18:35:48.735 SERIAL Buffer := 0x0108000400080284077a (10 bytes) 18:35:48.736 SERIAL » [ACK] (0x06) 18:35:48.740 SERIAL The receive buffer is empty, waiting for the next chunk... 18:35:48.744 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:35:48.738 CNTRLR [Node 008] The node is now awake. 18:35:48.749 SERIAL « [ACK] (0x06) 18:35:48.750 DRIVER Unexpected ACK received 18:35:48.750 SERIAL The receive buffer is empty, waiting for the next chunk... 18:35:48.760 SERIAL « 0x0104011301e8 (6 bytes) 18:35:48.767 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:35:48.762 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:35:48.766 SERIAL » [ACK] (0x06) 18:35:48.770 SERIAL The receive buffer is empty, waiting for the next chunk... 18:35:48.785 SERIAL « 0x010700138a00000263 (9 bytes) 18:35:48.787 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:35:48.785 SERIAL Buffer := 0x010700138a00000263 (9 bytes) 18:35:48.786 SERIAL » [ACK] (0x06) 18:35:48.789 SERIAL The receive buffer is empty, waiting for the next chunk... 18:35:48.788 DRIVER ACK received from node for current transaction. RTT = 44.76 ms 18:35:49.834 CNTRLR [Node 008] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:35:50.335 DRIVER » [Node 008] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:35:50.335 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:35:50.339 SERIAL « [ACK] (0x06) 18:35:50.340 DRIVER ACK received from controller for current transaction 18:35:50.340 SERIAL The receive buffer is empty, waiting for the next chunk... 18:35:50.346 SERIAL « 0x01 (1 bytes) 18:35:50.346 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:35:50.347 SERIAL « 0x04011301e8 (5 bytes) 18:35:50.349 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:35:50.348 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:35:50.348 SERIAL » [ACK] (0x06) 18:35:50.349 SERIAL The receive buffer is empty, waiting for the next chunk... 18:35:50.362 SERIAL « 0x01 (1 bytes) 18:35:50.362 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:35:50.364 SERIAL « 0x0700138a00000263 (8 bytes) 18:35:50.365 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:35:50.365 SERIAL Buffer := 0x010700138a00000263 (9 bytes) 18:35:50.365 SERIAL » [ACK] (0x06) 18:35:50.366 SERIAL The receive buffer is empty, waiting for the next chunk... 18:35:50.366 DRIVER ACK received from node for current transaction. RTT = 1623.10 ms 18:35:52.990 CNTRLR [Node 008] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:35:53.492 DRIVER » [Node 008] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:35:53.493 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:35:53.497 SERIAL « [ACK] (0x06) 18:35:53.497 DRIVER ACK received from controller for current transaction 18:35:53.498 SERIAL The receive buffer is empty, waiting for the next chunk... 18:35:53.503 SERIAL « 0x01 (1 bytes) 18:35:53.504 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:35:53.506 SERIAL « 0x04011301e8 (5 bytes) 18:35:53.507 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:35:53.506 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:35:53.506 SERIAL » [ACK] (0x06) 18:35:53.508 SERIAL The receive buffer is empty, waiting for the next chunk... 18:35:53.520 SERIAL « 0x01 (1 bytes) 18:35:53.520 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:35:53.522 SERIAL « 0x0700138a00000263 (8 bytes) 18:35:53.524 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:35:53.523 SERIAL Buffer := 0x010700138a00000263 (9 bytes) 18:35:53.523 SERIAL » [ACK] (0x06) 18:35:53.525 SERIAL The receive buffer is empty, waiting for the next chunk... 18:35:53.524 DRIVER ACK received from node for current transaction. RTT = 4781.36 ms 18:35:58.739 DRIVER The awake timeout for node 8 has elapsed. Assuming it is asleep. 18:35:58.740 CNTRLR [Node 008] The node is now asleep. 18:35:58.741 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:35:58.742 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:36:47.744 SERIAL « 0x01 (1 bytes) 18:36:47.744 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:36:47.746 CNTRLR [Node 002] [~] [Battery] level: 80 => 80 [Endpoint 0] 18:36:47.745 SERIAL « 0x09000400020380035020 (10 bytes) 18:36:47.745 SERIAL Buffer := 0x0109000400020380035020 (11 bytes) 18:36:47.749 SERIAL » [ACK] (0x06) 18:36:47.750 SERIAL The receive buffer is empty, waiting for the next chunk... 18:36:47.748 CNTRLR [Node 002] [~] [Battery] isLow: false => false [Endpoint 0] 18:36:47.765 SERIAL « 0x01 (1 bytes) 18:36:47.766 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:36:47.771 CNTRLR [Node 002] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:36:47.769 SERIAL « 0x0c0004000206430301420708ff (13 bytes) 18:36:47.769 SERIAL Buffer := 0x010c0004000206430301420708ff (14 bytes) 18:36:47.773 SERIAL » [ACK] (0x06) 18:36:47.773 SERIAL The receive buffer is empty, waiting for the next chunk... 18:36:47.785 SERIAL « 0x01 (1 bytes) 18:36:47.786 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:36:47.787 SERIAL « 0x0a00040002044608007fc6 (11 bytes) 18:36:47.788 CNTRLR [Node 002] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:36:47.787 SERIAL Buffer := 0x010a00040002044608007fc6 (12 bytes) 18:36:47.791 SERIAL » [ACK] (0x06) 18:36:47.792 SERIAL The receive buffer is empty, waiting for the next chunk... 18:36:47.790 CNTRLR [Node 002] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:36:47.808 SERIAL « 0x01080004000202840770 (10 bytes) 18:36:47.810 CNTRLR « [Node 002] received wakeup notification 18:36:47.814 DRIVER » [Node 002] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:36:47.808 SERIAL Buffer := 0x01080004000202840770 (10 bytes) 18:36:47.809 SERIAL » [ACK] (0x06) 18:36:47.812 SERIAL The receive buffer is empty, waiting for the next chunk... 18:36:47.814 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:36:47.810 CNTRLR [Node 002] The node is now awake. 18:36:47.819 SERIAL « [ACK] (0x06) 18:36:47.819 DRIVER Unexpected ACK received 18:36:47.820 SERIAL The receive buffer is empty, waiting for the next chunk... 18:36:47.824 SERIAL « 0x01 (1 bytes) 18:36:47.825 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:36:47.826 SERIAL « 0x04011301e8 (5 bytes) 18:36:47.828 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:36:47.827 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:36:47.827 SERIAL » [ACK] (0x06) 18:36:47.828 SERIAL The receive buffer is empty, waiting for the next chunk... 18:36:47.841 SERIAL « 0x01 (1 bytes) 18:36:47.841 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:36:47.843 SERIAL « 0x0700134a000002a3 (8 bytes) 18:36:47.844 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:36:47.843 SERIAL Buffer := 0x010700134a000002a3 (9 bytes) 18:36:47.844 SERIAL » [ACK] (0x06) 18:36:47.845 SERIAL The receive buffer is empty, waiting for the next chunk... 18:36:47.845 DRIVER ACK received from node for current transaction. RTT = 31.86 ms 18:36:48.877 CNTRLR [Node 002] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:36:49.377 DRIVER » [Node 002] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:36:49.378 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:36:49.382 SERIAL « [ACK] (0x06) 18:36:49.382 DRIVER ACK received from controller for current transaction 18:36:49.382 SERIAL The receive buffer is empty, waiting for the next chunk... 18:36:49.389 SERIAL « 0x01 (1 bytes) 18:36:49.389 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:36:49.390 SERIAL « 0x04011301e8 (5 bytes) 18:36:49.392 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:36:49.391 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:36:49.391 SERIAL » [ACK] (0x06) 18:36:49.392 SERIAL The receive buffer is empty, waiting for the next chunk... 18:36:49.404 SERIAL « 0x01 (1 bytes) 18:36:49.405 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:36:49.406 SERIAL « 0x0700134a000003a2 (8 bytes) 18:36:49.407 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:36:49.406 SERIAL Buffer := 0x010700134a000003a2 (9 bytes) 18:36:49.407 SERIAL » [ACK] (0x06) 18:36:49.408 SERIAL The receive buffer is empty, waiting for the next chunk... 18:36:49.408 DRIVER ACK received from node for current transaction. RTT = 1594.82 ms 18:36:52.004 CNTRLR [Node 002] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:36:52.504 DRIVER » [Node 002] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:36:52.505 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:36:52.508 SERIAL « [ACK] (0x06) 18:36:52.509 DRIVER ACK received from controller for current transaction 18:36:52.510 SERIAL The receive buffer is empty, waiting for the next chunk... 18:36:52.515 SERIAL « 0x01 (1 bytes) 18:36:52.515 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:36:52.517 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:36:52.516 SERIAL « 0x04011301e8 (5 bytes) 18:36:52.517 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:36:52.517 SERIAL » [ACK] (0x06) 18:36:52.518 SERIAL The receive buffer is empty, waiting for the next chunk... 18:36:52.532 SERIAL « 0x01 (1 bytes) 18:36:52.532 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:36:52.534 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:36:52.533 SERIAL « 0x0700134a000002a3 (8 bytes) 18:36:52.533 SERIAL Buffer := 0x010700134a000002a3 (9 bytes) 18:36:52.534 SERIAL » [ACK] (0x06) 18:36:52.535 SERIAL The receive buffer is empty, waiting for the next chunk... 18:36:52.535 DRIVER ACK received from node for current transaction. RTT = 4721.78 ms 18:36:57.801 SERIAL « 0x01 (1 bytes) 18:36:57.801 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:36:57.804 CNTRLR [Node 007] [~] [Multilevel Switch] currentValue: 0 => 99 [Endpoint 0] 18:36:57.802 SERIAL « 0x090004000703260363b0 (10 bytes) 18:36:57.803 SERIAL Buffer := 0x01090004000703260363b0 (11 bytes) 18:36:57.805 SERIAL » [ACK] (0x06) 18:36:57.806 SERIAL The receive buffer is empty, waiting for the next chunk... 18:36:57.811 DRIVER The awake timeout for node 2 has elapsed. Assuming it is asleep. 18:36:57.811 CNTRLR [Node 002] The node is now asleep. 18:36:57.814 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:36:57.815 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:36:58.813 SERIAL « 0x01 (1 bytes) 18:36:58.813 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:36:58.815 SERIAL « 0x10000400070a32022134000003b5000075 (17 bytes) 18:36:58.818 CNTRLR [Node 007] [Meter] value[66049]: metadata updated [Endpoint 0] 18:36:58.815 SERIAL Buffer := 0x0110000400070a32022134000003b5000075 (18 bytes) 18:36:58.827 SERIAL » [ACK] (0x06) 18:36:58.827 SERIAL The receive buffer is empty, waiting for the next chunk... 18:36:58.821 CNTRLR [Node 007] [~] [Meter] value[66049]: 0 => 94.9 [Endpoint 0] 18:36:58.823 CNTRLR [Node 007] [Meter] deltaTime[66049]: metadata updated [Endpoint 0] 18:36:58.825 CNTRLR [Node 007] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 18:36:59.810 SERIAL « 0x01 (1 bytes) 18:36:59.811 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:36:59.813 SERIAL « 0x10000400070a32022134000003b6000076 (17 bytes) 18:36:59.816 CNTRLR [Node 007] [Meter] value[66049]: metadata updated [Endpoint 0] 18:36:59.814 SERIAL Buffer := 0x0110000400070a32022134000003b6000076 (18 bytes) 18:36:59.823 SERIAL » [ACK] (0x06) 18:36:59.824 SERIAL The receive buffer is empty, waiting for the next chunk... 18:36:59.818 CNTRLR [Node 007] [~] [Meter] value[66049]: 94.9 => 95 [Endpoint 0] 18:36:59.819 CNTRLR [Node 007] [Meter] deltaTime[66049]: metadata updated [Endpoint 0] 18:36:59.822 CNTRLR [Node 007] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 18:37:01.417 SERIAL « 0x01 (1 bytes) 18:37:01.418 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:37:01.423 SERIAL « 0x160049840410040804804681728f75438684ef46818f11 (23 bytes) 18:37:01.425 CNTRLR « [Node 004] Received updated node info 18:37:01.433 DRIVER » [Node 004] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:37:01.424 SERIAL Buffer := 0x01160049840410040804804681728f75438684ef46818f11 (24 bytes) 18:37:01.424 SERIAL » [ACK] (0x06) 18:37:01.431 SERIAL The receive buffer is empty, waiting for the next chunk... 18:37:01.434 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:37:01.425 CNTRLR [Node 004] The node is now awake. 18:37:01.439 SERIAL « [ACK] (0x06) 18:37:01.442 DRIVER Unexpected ACK received 18:37:01.443 SERIAL The receive buffer is empty, waiting for the next chunk... 18:37:01.450 SERIAL « 0x01 (1 bytes) 18:37:01.451 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:37:01.455 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:37:01.453 SERIAL « 0x04011301e8 (5 bytes) 18:37:01.453 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:37:01.454 SERIAL » [ACK] (0x06) 18:37:01.456 SERIAL The receive buffer is empty, waiting for the next chunk... 18:37:01.461 SERIAL « 0x01 (1 bytes) 18:37:01.462 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:37:01.464 SERIAL « 0x070013620000028b (8 bytes) 18:37:01.466 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:37:01.465 SERIAL Buffer := 0x01070013620000028b (9 bytes) 18:37:01.465 SERIAL » [ACK] (0x06) 18:37:01.467 SERIAL The receive buffer is empty, waiting for the next chunk... 18:37:01.466 DRIVER ACK received from node for current transaction. RTT = 34.02 ms 18:37:02.502 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:37:03.007 DRIVER » [Node 004] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:37:03.008 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:37:03.016 SERIAL « [ACK] (0x06) 18:37:03.017 DRIVER ACK received from controller for current transaction 18:37:03.017 SERIAL The receive buffer is empty, waiting for the next chunk... 18:37:03.023 SERIAL « 0x01 (1 bytes) 18:37:03.023 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:37:03.025 SERIAL « 0x04011301e8 (5 bytes) 18:37:03.026 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:37:03.025 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:37:03.026 SERIAL » [ACK] (0x06) 18:37:03.027 SERIAL The receive buffer is empty, waiting for the next chunk... 18:37:03.044 SERIAL « 0x01 (1 bytes) 18:37:03.045 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:37:03.048 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:37:03.047 SERIAL « 0x070013620000028b (8 bytes) 18:37:03.047 SERIAL Buffer := 0x01070013620000028b (9 bytes) 18:37:03.047 SERIAL » [ACK] (0x06) 18:37:03.049 SERIAL The receive buffer is empty, waiting for the next chunk... 18:37:03.048 DRIVER ACK received from node for current transaction. RTT = 1616.08 ms 18:37:05.665 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:37:06.166 DRIVER » [Node 004] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:37:06.167 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:37:06.171 SERIAL « [ACK] (0x06) 18:37:06.171 DRIVER ACK received from controller for current transaction 18:37:06.172 SERIAL The receive buffer is empty, waiting for the next chunk... 18:37:06.177 SERIAL « 0x01 (1 bytes) 18:37:06.178 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:37:06.179 SERIAL « 0x04011301e8 (5 bytes) 18:37:06.181 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:37:06.180 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:37:06.180 SERIAL » [ACK] (0x06) 18:37:06.181 SERIAL The receive buffer is empty, waiting for the next chunk... 18:37:06.194 SERIAL « 0x01 (1 bytes) 18:37:06.194 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:37:06.196 SERIAL « 0x070013620000028b (8 bytes) 18:37:06.197 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:37:06.196 SERIAL Buffer := 0x01070013620000028b (9 bytes) 18:37:06.197 SERIAL » [ACK] (0x06) 18:37:06.198 SERIAL The receive buffer is empty, waiting for the next chunk... 18:37:06.198 DRIVER ACK received from node for current transaction. RTT = 4765.41 ms 18:37:11.427 DRIVER The awake timeout for node 4 has elapsed. Assuming it is asleep. 18:37:11.428 CNTRLR [Node 004] The node is now asleep. 18:37:11.429 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:37:11.430 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:38:13.941 SERIAL « 0x01 (1 bytes) 18:38:13.941 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:38:13.943 CNTRLR [Node 005] [~] [Battery] level: 58 => 58 [Endpoint 0] 18:38:13.942 SERIAL « 0x09000400050380033a4d (10 bytes) 18:38:13.942 SERIAL Buffer := 0x0109000400050380033a4d (11 bytes) 18:38:13.947 SERIAL » [ACK] (0x06) 18:38:13.948 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:13.946 CNTRLR [Node 005] [~] [Battery] isLow: false => false [Endpoint 0] 18:38:13.965 SERIAL « 0x010c0004000506430301420708f8 (14 bytes) 18:38:13.967 CNTRLR [Node 005] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:38:13.966 SERIAL Buffer := 0x010c0004000506430301420708f8 (14 bytes) 18:38:13.968 SERIAL » [ACK] (0x06) 18:38:13.969 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:13.983 SERIAL « 0x01 (1 bytes) 18:38:13.983 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:38:13.985 CNTRLR [Node 005] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:38:13.984 SERIAL « 0x0a00040005044608007fc1 (11 bytes) 18:38:13.984 SERIAL Buffer := 0x010a00040005044608007fc1 (12 bytes) 18:38:13.989 SERIAL » [ACK] (0x06) 18:38:13.990 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:13.987 CNTRLR [Node 005] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:38:14.008 SERIAL « 0x01080004000502840777 (10 bytes) 18:38:14.011 CNTRLR « [Node 005] received wakeup notification 18:38:14.016 DRIVER » [Node 005] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:38:14.009 SERIAL Buffer := 0x01080004000502840777 (10 bytes) 18:38:14.010 SERIAL » [ACK] (0x06) 18:38:14.014 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:14.018 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:38:14.012 CNTRLR [Node 005] The node is now awake. 18:38:14.026 SERIAL « [ACK] (0x06) 18:38:14.027 DRIVER Unexpected ACK received 18:38:14.028 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:14.032 SERIAL « 0x01 (1 bytes) 18:38:14.033 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:38:14.037 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:38:14.035 SERIAL « 0x04011301e8 (5 bytes) 18:38:14.036 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:38:14.036 SERIAL » [ACK] (0x06) 18:38:14.037 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:14.047 SERIAL « 0x01 (1 bytes) 18:38:14.048 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:38:14.053 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:38:14.049 SERIAL « 0x07001356000003be (8 bytes) 18:38:14.049 SERIAL Buffer := 0x0107001356000003be (9 bytes) 18:38:14.049 SERIAL » [ACK] (0x06) 18:38:14.054 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:14.054 DRIVER ACK received from node for current transaction. RTT = 38.05 ms 18:38:15.093 CNTRLR [Node 005] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:38:15.593 DRIVER » [Node 005] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:38:15.594 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:38:15.599 SERIAL « [ACK] (0x06) 18:38:15.599 DRIVER ACK received from controller for current transaction 18:38:15.600 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:15.606 SERIAL « 0x01 (1 bytes) 18:38:15.606 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:38:15.607 SERIAL « 0x04011301e8 (5 bytes) 18:38:15.608 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:38:15.607 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:38:15.608 SERIAL » [ACK] (0x06) 18:38:15.608 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:15.622 SERIAL « 0x01 (1 bytes) 18:38:15.623 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:38:15.626 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:38:15.625 SERIAL « 0x07001356000002bf (8 bytes) 18:38:15.625 SERIAL Buffer := 0x0107001356000002bf (9 bytes) 18:38:15.625 SERIAL » [ACK] (0x06) 18:38:15.627 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:15.626 DRIVER ACK received from node for current transaction. RTT = 1610.76 ms 18:38:18.238 CNTRLR [Node 005] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:38:18.739 DRIVER » [Node 005] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:38:18.739 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:38:18.743 SERIAL « [ACK] (0x06) 18:38:18.744 DRIVER ACK received from controller for current transaction 18:38:18.744 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:18.750 SERIAL « 0x01 (1 bytes) 18:38:18.750 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:38:18.752 SERIAL « 0x04011301e8 (5 bytes) 18:38:18.753 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:38:18.752 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:38:18.753 SERIAL » [ACK] (0x06) 18:38:18.754 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:18.767 SERIAL « 0x01 (1 bytes) 18:38:18.768 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:38:18.771 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:38:18.769 SERIAL « 0x07001356000003be (8 bytes) 18:38:18.769 SERIAL Buffer := 0x0107001356000003be (9 bytes) 18:38:18.769 SERIAL » [ACK] (0x06) 18:38:18.772 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:18.772 DRIVER ACK received from node for current transaction. RTT = 4756.19 ms 18:38:24.013 DRIVER The awake timeout for node 5 has elapsed. Assuming it is asleep. 18:38:24.014 CNTRLR [Node 005] The node is now asleep. 18:38:24.015 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:38:24.016 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:38:48.480 SERIAL « 0x01 (1 bytes) 18:38:48.481 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:38:48.483 CNTRLR [Node 004] [~] [Battery] level: 40 => 40 [Endpoint 0] 18:38:48.482 SERIAL « 0x0900040004038003285e (10 bytes) 18:38:48.482 SERIAL Buffer := 0x010900040004038003285e (11 bytes) 18:38:48.486 SERIAL » [ACK] (0x06) 18:38:48.489 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:48.485 CNTRLR [Node 004] [~] [Battery] isLow: false => false [Endpoint 0] 18:38:48.506 SERIAL « 0x010c00040004064303014201f403 (14 bytes) 18:38:48.507 CNTRLR [Node 004] [~] [Thermostat Setpoint] setpoint[1]: 5 => 5 [Endpoint 0] 18:38:48.506 SERIAL Buffer := 0x010c00040004064303014201f403 (14 bytes) 18:38:48.509 SERIAL » [ACK] (0x06) 18:38:48.510 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:48.522 SERIAL « 0x01 (1 bytes) 18:38:48.522 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:38:48.524 SERIAL « 0x0a00040004044608007fc0 (11 bytes) 18:38:48.526 CNTRLR [Node 004] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:38:48.525 SERIAL Buffer := 0x010a00040004044608007fc0 (12 bytes) 18:38:48.529 SERIAL » [ACK] (0x06) 18:38:48.529 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:48.527 CNTRLR [Node 004] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:38:48.547 SERIAL « 0x01080004000402840776 (10 bytes) 18:38:48.549 CNTRLR « [Node 004] received wakeup notification 18:38:48.552 DRIVER » [Node 004] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:38:48.548 SERIAL Buffer := 0x01080004000402840776 (10 bytes) 18:38:48.549 SERIAL » [ACK] (0x06) 18:38:48.551 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:48.555 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:38:48.550 CNTRLR [Node 004] The node is now awake. 18:38:48.561 SERIAL « [ACK] (0x06) 18:38:48.561 DRIVER Unexpected ACK received 18:38:48.562 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:48.567 SERIAL « 0x01 (1 bytes) 18:38:48.567 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:38:48.569 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:38:48.568 SERIAL « 0x04011301e8 (5 bytes) 18:38:48.569 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:38:48.569 SERIAL » [ACK] (0x06) 18:38:48.570 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:48.583 SERIAL « 0x01 (1 bytes) 18:38:48.584 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:38:48.585 SERIAL « 0x070013620000028b (8 bytes) 18:38:48.586 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:38:48.586 SERIAL Buffer := 0x01070013620000028b (9 bytes) 18:38:48.586 SERIAL » [ACK] (0x06) 18:38:48.588 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:48.587 DRIVER ACK received from node for current transaction. RTT = 35.20 ms 18:38:49.624 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:38:50.125 DRIVER » [Node 004] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:38:50.126 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:38:50.130 SERIAL « [ACK] (0x06) 18:38:50.130 DRIVER ACK received from controller for current transaction 18:38:50.130 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:50.137 SERIAL « 0x01 (1 bytes) 18:38:50.137 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:38:50.138 SERIAL « 0x04011301e8 (5 bytes) 18:38:50.139 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:38:50.138 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:38:50.139 SERIAL » [ACK] (0x06) 18:38:50.140 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:50.153 SERIAL « 0x01 (1 bytes) 18:38:50.153 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:38:50.155 SERIAL « 0x070013620000028b (8 bytes) 18:38:50.156 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:38:50.156 DRIVER ACK received from node for current transaction. RTT = 1604.74 ms 18:38:50.155 SERIAL Buffer := 0x01070013620000028b (9 bytes) 18:38:50.156 SERIAL » [ACK] (0x06) 18:38:50.157 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:52.761 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:38:53.263 DRIVER » [Node 004] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:38:53.263 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:38:53.266 SERIAL « [ACK] (0x06) 18:38:53.267 DRIVER ACK received from controller for current transaction 18:38:53.267 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:53.273 SERIAL « 0x01 (1 bytes) 18:38:53.273 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:38:53.276 SERIAL « 0x04011301e8 (5 bytes) 18:38:53.277 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:38:53.276 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:38:53.276 SERIAL » [ACK] (0x06) 18:38:53.277 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:53.290 SERIAL « 0x0107 (2 bytes) 18:38:53.290 SERIAL [incomplete] Buffer := 0x0107 (2 bytes) 18:38:53.292 SERIAL « 0x0013620000028b (7 bytes) 18:38:53.293 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:38:53.292 SERIAL Buffer := 0x01070013620000028b (9 bytes) 18:38:53.293 SERIAL » [ACK] (0x06) 18:38:53.294 SERIAL The receive buffer is empty, waiting for the next chunk... 18:38:53.293 DRIVER ACK received from node for current transaction. RTT = 4741.75 ms 18:38:58.551 DRIVER The awake timeout for node 4 has elapsed. Assuming it is asleep. 18:38:58.551 CNTRLR [Node 004] The node is now asleep. 18:38:58.553 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:38:58.553 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:39:11.450 SERIAL « 0x01 (1 bytes) 18:39:11.450 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:39:11.452 SERIAL « 0x09000400060380035024 (10 bytes) 18:39:11.455 CNTRLR [Node 006] [~] [Battery] level: 80 => 80 [Endpoint 0] 18:39:11.452 SERIAL Buffer := 0x0109000400060380035024 (11 bytes) 18:39:11.457 SERIAL » [ACK] (0x06) 18:39:11.458 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:11.456 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 0] 18:39:11.471 SERIAL « 0x01 (1 bytes) 18:39:11.471 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:39:11.475 SERIAL « 0x0c000400060643030142019065 (13 bytes) 18:39:11.477 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpoint[1]: 4 => 4 [Endpoint 0] 18:39:11.476 SERIAL Buffer := 0x010c000400060643030142019065 (14 bytes) 18:39:11.478 SERIAL » [ACK] (0x06) 18:39:11.479 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:11.491 SERIAL « 0x01 (1 bytes) 18:39:11.491 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:39:11.493 SERIAL « 0x0a00040006044608007fc2 (11 bytes) 18:39:11.494 CNTRLR [Node 006] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:39:11.496 CNTRLR [Node 006] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:39:11.493 SERIAL Buffer := 0x010a00040006044608007fc2 (12 bytes) 18:39:11.497 SERIAL » [ACK] (0x06) 18:39:11.498 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:11.512 SERIAL « 0x01 (1 bytes) 18:39:11.513 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:39:11.515 SERIAL « 0x080004000602840774 (9 bytes) 18:39:11.518 CNTRLR « [Node 006] received wakeup notification 18:39:11.521 DRIVER » [Node 006] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:39:11.517 SERIAL Buffer := 0x01080004000602840774 (10 bytes) 18:39:11.518 SERIAL » [ACK] (0x06) 18:39:11.520 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:11.522 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:39:11.519 CNTRLR [Node 006] The node is now awake. 18:39:11.526 SERIAL « [ACK] (0x06) 18:39:11.527 DRIVER Unexpected ACK received 18:39:11.528 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:11.533 SERIAL « 0x01 (1 bytes) 18:39:11.534 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:39:11.536 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:39:11.534 SERIAL « 0x04011301e8 (5 bytes) 18:39:11.535 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:39:11.535 SERIAL » [ACK] (0x06) 18:39:11.536 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:11.549 SERIAL « 0x01 (1 bytes) 18:39:11.550 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:39:11.551 SERIAL « 0x0700136e00000287 (8 bytes) 18:39:11.553 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:39:11.554 DRIVER ACK received from node for current transaction. RTT = 32.59 ms 18:39:11.552 SERIAL Buffer := 0x010700136e00000287 (9 bytes) 18:39:11.552 SERIAL » [ACK] (0x06) 18:39:11.554 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:12.587 CNTRLR [Node 006] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:39:13.088 DRIVER » [Node 006] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:39:13.088 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:39:13.092 SERIAL « [ACK] (0x06) 18:39:13.092 DRIVER ACK received from controller for current transaction 18:39:13.093 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:13.098 SERIAL « 0x01 (1 bytes) 18:39:13.099 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:39:13.100 SERIAL « 0x04011301e8 (5 bytes) 18:39:13.102 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:39:13.101 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:39:13.101 SERIAL » [ACK] (0x06) 18:39:13.102 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:13.115 SERIAL « 0x01 (1 bytes) 18:39:13.116 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:39:13.119 SERIAL « 0x0700136e00000386 (8 bytes) 18:39:13.120 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:39:13.121 DRIVER ACK received from node for current transaction. RTT = 1599.88 ms 18:39:13.119 SERIAL Buffer := 0x010700136e00000386 (9 bytes) 18:39:13.120 SERIAL » [ACK] (0x06) 18:39:13.121 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:15.721 CNTRLR [Node 006] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:39:16.222 DRIVER » [Node 006] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:39:16.222 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:39:16.226 SERIAL « [ACK] (0x06) 18:39:16.227 DRIVER ACK received from controller for current transaction 18:39:16.227 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:16.233 SERIAL « 0x0104 (2 bytes) 18:39:16.233 SERIAL [incomplete] Buffer := 0x0104 (2 bytes) 18:39:16.235 SERIAL « 0x011301e8 (4 bytes) 18:39:16.236 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:39:16.235 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:39:16.236 SERIAL » [ACK] (0x06) 18:39:16.236 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:16.250 SERIAL « 0x01 (1 bytes) 18:39:16.251 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:39:16.253 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:39:16.252 SERIAL « 0x0700136e00000287 (8 bytes) 18:39:16.252 SERIAL Buffer := 0x010700136e00000287 (9 bytes) 18:39:16.252 SERIAL » [ACK] (0x06) 18:39:16.254 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:16.253 DRIVER ACK received from node for current transaction. RTT = 4732.21 ms 18:39:21.519 DRIVER The awake timeout for node 6 has elapsed. Assuming it is asleep. 18:39:21.520 CNTRLR [Node 006] The node is now asleep. 18:39:21.521 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:39:21.524 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] 18:39:54.185 SERIAL « 0x01 (1 bytes) 18:39:54.185 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:39:54.187 SERIAL « 0x160049840410040804804681728f75438684ef46818f11 (23 bytes) 18:39:54.188 CNTRLR « [Node 004] Received updated node info 18:39:54.192 DRIVER » [Node 004] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:39:54.188 CNTRLR [Node 004] The node is now awake. 18:39:54.187 SERIAL Buffer := 0x01160049840410040804804681728f75438684ef46818f11 (24 bytes) 18:39:54.188 SERIAL » [ACK] (0x06) 18:39:54.190 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:54.192 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:39:54.196 SERIAL « [ACK] (0x06) 18:39:54.196 DRIVER Unexpected ACK received 18:39:54.197 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:54.205 SERIAL « 0x0104011301e8 (6 bytes) 18:39:54.206 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:39:54.205 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:39:54.205 SERIAL » [ACK] (0x06) 18:39:54.206 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:54.219 SERIAL « 0x01 (1 bytes) 18:39:54.219 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:39:54.221 SERIAL « 0x070013620000028b (8 bytes) 18:39:54.222 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:39:54.221 SERIAL Buffer := 0x01070013620000028b (9 bytes) 18:39:54.221 SERIAL » [ACK] (0x06) 18:39:54.223 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:54.222 DRIVER ACK received from node for current transaction. RTT = 31.02 ms 18:39:55.254 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:39:55.755 DRIVER » [Node 004] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 98 └─[ThermostatSetpointCCGet] payload: 0x02 18:39:55.755 SERIAL » 0x010a001304034302022562e5 (12 bytes) 18:39:55.759 SERIAL « [ACK] (0x06) 18:39:55.759 DRIVER ACK received from controller for current transaction 18:39:55.760 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:55.765 SERIAL « 0x01 (1 bytes) 18:39:55.766 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:39:55.768 SERIAL « 0x04011301e8 (5 bytes) 18:39:55.770 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:39:55.769 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:39:55.769 SERIAL » [ACK] (0x06) 18:39:55.770 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:55.782 SERIAL « 0x01 (1 bytes) 18:39:55.783 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:39:55.785 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 18:39:55.784 SERIAL « 0x070013620000028b (8 bytes) 18:39:55.784 SERIAL Buffer := 0x01070013620000028b (9 bytes) 18:39:55.784 SERIAL » [ACK] (0x06) 18:39:55.786 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:55.785 DRIVER ACK received from node for current transaction. RTT = 1593.94 ms 18:39:56.315 SERIAL « 0x01 (1 bytes) 18:39:56.316 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:39:56.317 SERIAL « 0x09000400030380033342 (10 bytes) 18:39:56.319 CNTRLR [Node 003] [~] [Battery] level: 51 => 51 [Endpoint 0] 18:39:56.318 SERIAL Buffer := 0x0109000400030380033342 (11 bytes) 18:39:56.322 SERIAL » [ACK] (0x06) 18:39:56.323 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:56.320 CNTRLR [Node 003] [~] [Battery] isLow: false => false [Endpoint 0] 18:39:56.340 SERIAL « 0x01 (1 bytes) 18:39:56.340 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:39:56.343 CNTRLR [Node 003] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:39:56.346 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[ThermostatSetpointCCReport] payload: 0x01420708 18:39:56.341 SERIAL « 0x0c0004000306430301420708fe (13 bytes) 18:39:56.342 SERIAL Buffer := 0x010c0004000306430301420708fe (14 bytes) 18:39:56.345 SERIAL » [ACK] (0x06) 18:39:56.350 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:56.353 SERIAL » 0x010a00130303430202257afa (12 bytes) 18:39:56.347 CNTRLR [Node 003] The node is now awake. 18:39:56.350 CNTRLR « [Node 004] received current value of setpoint Cooling: 18 °C 18:39:56.350 CNTRLR » [Node 004] querying current value of setpoint Furnace... 18:39:56.348 DRIVER ACK already received, resolving transaction 18:39:56.349 DRIVER resuming send queue 18:39:56.353 DRIVER » [Node 003] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 122 └─[ThermostatSetpointCCGet] payload: 0x02 18:39:56.353 DRIVER workOffSendQueue > skipping because a transaction is pending 18:39:56.354 DRIVER workOffSendQueue > skipping because a transaction is pending 18:39:56.360 SERIAL « 0x010a00040003044608007fc7 (12 bytes) 18:39:56.362 CNTRLR [Node 003] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:39:56.360 SERIAL Buffer := 0x010a00040003044608007fc7 (12 bytes) 18:39:56.365 SERIAL » [ACK] (0x06) 18:39:56.367 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:56.363 CNTRLR [Node 003] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:39:56.370 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 18:39:56.370 SERIAL « [CAN] (0x18) 18:39:56.371 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:56.377 SERIAL « 0x01 (1 bytes) 18:39:56.379 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:39:56.382 CNTRLR « [Node 003] received wakeup notification 18:39:56.380 SERIAL « 0x080004000302840771 (9 bytes) 18:39:56.381 SERIAL Buffer := 0x01080004000302840771 (10 bytes) 18:39:56.381 SERIAL » [ACK] (0x06) 18:39:56.384 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:56.471 DRIVER » [Node 003] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 122 └─[ThermostatSetpointCCGet] payload: 0x02 18:39:56.471 SERIAL » 0x010a00130303430202257afa (12 bytes) 18:39:56.474 SERIAL « [ACK] (0x06) 18:39:56.475 DRIVER ACK received from controller for current transaction 18:39:56.475 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:56.481 SERIAL « 0x01 (1 bytes) 18:39:56.482 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:39:56.483 SERIAL « 0x04011301e8 (5 bytes) 18:39:56.484 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:39:56.483 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:39:56.484 SERIAL » [ACK] (0x06) 18:39:56.485 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:56.498 SERIAL « 0x01 (1 bytes) 18:39:56.498 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:39:56.502 SERIAL « 0x0700137a00000293 (8 bytes) 18:39:56.504 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 18:39:56.503 SERIAL Buffer := 0x010700137a00000293 (9 bytes) 18:39:56.503 SERIAL » [ACK] (0x06) 18:39:56.505 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:56.504 DRIVER ACK received from node for current transaction. RTT = 152.10 ms 18:39:57.657 CNTRLR [Node 003] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:39:58.157 DRIVER » [Node 003] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 122 └─[ThermostatSetpointCCGet] payload: 0x02 18:39:58.158 SERIAL » 0x010a00130303430202257afa (12 bytes) 18:39:58.162 SERIAL « [ACK] (0x06) 18:39:58.163 DRIVER ACK received from controller for current transaction 18:39:58.163 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:58.168 SERIAL « 0x01 (1 bytes) 18:39:58.169 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:39:58.170 SERIAL « 0x04011301e8 (5 bytes) 18:39:58.172 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:39:58.171 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:39:58.172 SERIAL » [ACK] (0x06) 18:39:58.172 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:58.185 SERIAL « 0x01 (1 bytes) 18:39:58.186 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:39:58.187 SERIAL « 0x0700137a00000392 (8 bytes) 18:39:58.189 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 18:39:58.188 SERIAL Buffer := 0x010700137a00000392 (9 bytes) 18:39:58.188 SERIAL » [ACK] (0x06) 18:39:58.190 SERIAL The receive buffer is empty, waiting for the next chunk... 18:39:58.189 DRIVER ACK received from node for current transaction. RTT = 1836.79 ms 18:40:01.026 CNTRLR [Node 003] The node did not respond to the current transaction after 3 attempt s. It is probably asleep, moving its messages to the wakeup queue. 18:40:01.028 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 139 └─[ThermostatSetpointCCGet] payload: 0x07 18:40:01.029 SERIAL » 0x010a00130403430207258b09 (12 bytes) 18:40:01.027 CNTRLR [Node 003] The node is now asleep. 18:40:01.037 SERIAL « [ACK] (0x06) 18:40:01.038 DRIVER ACK received from controller for current transaction 18:40:01.039 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:01.040 SERIAL « 0x01 (1 bytes) 18:40:01.040 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:40:01.049 SERIAL « 0x04011301e8 (5 bytes) 18:40:01.050 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:40:01.049 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:40:01.050 SERIAL » [ACK] (0x06) 18:40:01.051 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:01.060 SERIAL « 0x010700138b00000262 (9 bytes) 18:40:01.064 DRIVER « [REQ] [SendData] [confirmation] callbackId: 139 transmitStatus: OK 18:40:01.063 SERIAL Buffer := 0x010700138b00000262 (9 bytes) 18:40:01.064 SERIAL » [ACK] (0x06) 18:40:01.067 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:01.066 DRIVER ACK received from node for current transaction. RTT = 38.02 ms 18:40:02.106 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:40:02.607 DRIVER » [Node 004] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 139 └─[ThermostatSetpointCCGet] payload: 0x07 18:40:02.607 SERIAL » 0x010a00130403430207258b09 (12 bytes) 18:40:02.611 SERIAL « [ACK] (0x06) 18:40:02.611 DRIVER ACK received from controller for current transaction 18:40:02.611 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:02.617 SERIAL « 0x01 (1 bytes) 18:40:02.617 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:40:02.619 SERIAL « 0x04011301e8 (5 bytes) 18:40:02.620 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:40:02.619 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:40:02.620 SERIAL » [ACK] (0x06) 18:40:02.621 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:02.634 SERIAL « 0x01 (1 bytes) 18:40:02.635 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:40:02.636 SERIAL « 0x0700138b00000262 (8 bytes) 18:40:02.637 DRIVER « [REQ] [SendData] [confirmation] callbackId: 139 transmitStatus: OK 18:40:02.637 SERIAL Buffer := 0x010700138b00000262 (9 bytes) 18:40:02.637 SERIAL » [ACK] (0x06) 18:40:02.639 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:02.638 DRIVER ACK received from node for current transaction. RTT = 1609.85 ms 18:40:05.248 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:40:05.749 DRIVER » [Node 004] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 139 └─[ThermostatSetpointCCGet] payload: 0x07 18:40:05.750 SERIAL » 0x010a00130403430207258b09 (12 bytes) 18:40:05.754 SERIAL « [ACK] (0x06) 18:40:05.755 DRIVER ACK received from controller for current transaction 18:40:05.757 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:05.761 SERIAL « 0x01 (1 bytes) 18:40:05.762 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:40:05.764 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:40:05.763 SERIAL « 0x04011301e8 (5 bytes) 18:40:05.764 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:40:05.764 SERIAL » [ACK] (0x06) 18:40:05.765 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:05.778 SERIAL « 0x01 (1 bytes) 18:40:05.778 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:40:05.780 SERIAL « 0x0700138b00000262 (8 bytes) 18:40:05.782 DRIVER « [REQ] [SendData] [confirmation] callbackId: 139 transmitStatus: OK 18:40:05.781 SERIAL Buffer := 0x010700138b00000262 (9 bytes) 18:40:05.781 SERIAL » [ACK] (0x06) 18:40:05.783 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:05.782 DRIVER ACK received from node for current transaction. RTT = 4753.99 ms 18:40:06.349 DRIVER The awake timeout for node 4 has elapsed. Assuming it is asleep. 18:40:06.349 CNTRLR [Node 004] The node is now asleep. 18:40:06.351 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:40:06.351 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:40:42.937 SERIAL « 0x01 (1 bytes) 18:40:42.937 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:40:42.942 CNTRLR [Node 008] [~] [Battery] level: 72 => 72 [Endpoint 0] 18:40:42.940 SERIAL « 0x09000400080380034832 (10 bytes) 18:40:42.941 SERIAL Buffer := 0x0109000400080380034832 (11 bytes) 18:40:42.945 SERIAL » [ACK] (0x06) 18:40:42.946 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:42.944 CNTRLR [Node 008] [~] [Battery] isLow: false => false [Endpoint 0] 18:40:42.955 SERIAL « 0x01 (1 bytes) 18:40:42.956 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:40:42.960 CNTRLR [Node 008] [~] [Thermostat Setpoint] setpoint[1]: 4.5 => 4.5 [Endpoint 0] 18:40:42.957 SERIAL « 0x0c00040008064303014201c239 (13 bytes) 18:40:42.958 SERIAL Buffer := 0x010c00040008064303014201c239 (14 bytes) 18:40:42.961 SERIAL » [ACK] (0x06) 18:40:42.962 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:42.975 SERIAL « 0x01 (1 bytes) 18:40:42.975 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:40:42.976 SERIAL « 0x0a00040008044608007fcc (11 bytes) 18:40:42.978 CNTRLR [Node 008] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:40:42.977 SERIAL Buffer := 0x010a00040008044608007fcc (12 bytes) 18:40:42.981 SERIAL » [ACK] (0x06) 18:40:42.981 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:42.979 CNTRLR [Node 008] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:40:42.997 SERIAL « 0x01 (1 bytes) 18:40:42.998 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:40:43.001 CNTRLR [Node 008] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 18:40:42.999 SERIAL « 0x0c000400080631050142079c15 (13 bytes) 18:40:43.000 SERIAL Buffer := 0x010c000400080631050142079c15 (14 bytes) 18:40:43.004 SERIAL » [ACK] (0x06) 18:40:43.005 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:43.003 CNTRLR [Node 008] [~] [Multilevel Sensor] Air temperature: 19.49 => 19.4 [Endpoint 0] 8 18:40:43.017 SERIAL « 0x01 (1 bytes) 18:40:43.017 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:40:43.020 CNTRLR « [Node 008] received wakeup notification 18:40:43.023 DRIVER » [Node 008] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:40:43.019 SERIAL « 0x08000400080284077a (9 bytes) 18:40:43.019 SERIAL Buffer := 0x0108000400080284077a (10 bytes) 18:40:43.020 SERIAL » [ACK] (0x06) 18:40:43.022 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:43.024 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:40:43.021 CNTRLR [Node 008] The node is now awake. 18:40:43.028 SERIAL « [ACK] (0x06) 18:40:43.028 DRIVER Unexpected ACK received 18:40:43.029 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:43.034 SERIAL « 0x01 (1 bytes) 18:40:43.034 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:40:43.036 SERIAL « 0x04011301e8 (5 bytes) 18:40:43.038 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:40:43.037 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:40:43.037 SERIAL » [ACK] (0x06) 18:40:43.038 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:43.051 SERIAL « 0x01 (1 bytes) 18:40:43.052 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:40:43.056 SERIAL « 0x0700138a00000263 (8 bytes) 18:40:43.057 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:40:43.056 SERIAL Buffer := 0x010700138a00000263 (9 bytes) 18:40:43.056 SERIAL » [ACK] (0x06) 18:40:43.058 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:43.057 DRIVER ACK received from node for current transaction. RTT = 34.50 ms 18:40:44.093 CNTRLR [Node 008] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:40:44.593 DRIVER » [Node 008] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:40:44.594 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:40:44.598 SERIAL « [ACK] (0x06) 18:40:44.598 DRIVER ACK received from controller for current transaction 18:40:44.598 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:44.604 SERIAL « 0x01 (1 bytes) 18:40:44.604 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:40:44.606 SERIAL « 0x04011301e8 (5 bytes) 18:40:44.607 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:40:44.606 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:40:44.607 SERIAL » [ACK] (0x06) 18:40:44.608 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:44.621 SERIAL « 0x01 (1 bytes) 18:40:44.621 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:40:44.623 SERIAL « 0x0700138a00000263 (8 bytes) 18:40:44.624 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:40:44.624 SERIAL Buffer := 0x010700138a00000263 (9 bytes) 18:40:44.624 SERIAL » [ACK] (0x06) 18:40:44.625 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:44.625 DRIVER ACK received from node for current transaction. RTT = 1602.02 ms 18:40:47.229 CNTRLR [Node 008] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:40:47.730 DRIVER » [Node 008] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:40:47.730 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:40:47.734 SERIAL « [ACK] (0x06) 18:40:47.734 DRIVER ACK received from controller for current transaction 18:40:47.735 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:47.740 SERIAL « 0x01 (1 bytes) 18:40:47.741 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:40:47.743 SERIAL « 0x04011301e8 (5 bytes) 18:40:47.744 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:40:47.743 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:40:47.744 SERIAL » [ACK] (0x06) 18:40:47.746 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:47.758 SERIAL « 0x01 (1 bytes) 18:40:47.758 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:40:47.760 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:40:47.759 SERIAL « 0x0700138a00000263 (8 bytes) 18:40:47.759 SERIAL Buffer := 0x010700138a00000263 (9 bytes) 18:40:47.760 SERIAL » [ACK] (0x06) 18:40:47.761 SERIAL The receive buffer is empty, waiting for the next chunk... 18:40:47.761 DRIVER ACK received from node for current transaction. RTT = 4737.92 ms 18:40:53.022 DRIVER The awake timeout for node 8 has elapsed. Assuming it is asleep. 18:40:53.023 CNTRLR [Node 008] The node is now asleep. 18:40:53.024 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:40:53.025 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:41:39.168 SERIAL « 0x01 (1 bytes) 18:41:39.168 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:41:39.171 CNTRLR [Node 002] [~] [Battery] level: 80 => 80 [Endpoint 0] 18:41:39.169 SERIAL « 0x09000400020380035020 (10 bytes) 18:41:39.170 SERIAL Buffer := 0x0109000400020380035020 (11 bytes) 18:41:39.173 SERIAL » [ACK] (0x06) 18:41:39.174 SERIAL The receive buffer is empty, waiting for the next chunk... 18:41:39.172 CNTRLR [Node 002] [~] [Battery] isLow: false => false [Endpoint 0] 18:41:39.188 SERIAL « 0x01 (1 bytes) 18:41:39.188 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:41:39.191 SERIAL « 0x0c0004000206430301420708ff (13 bytes) 18:41:39.193 CNTRLR [Node 002] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:41:39.191 SERIAL Buffer := 0x010c0004000206430301420708ff (14 bytes) 18:41:39.194 SERIAL » [ACK] (0x06) 18:41:39.194 SERIAL The receive buffer is empty, waiting for the next chunk... 18:41:39.209 SERIAL « 0x01 (1 bytes) 18:41:39.209 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:41:39.212 CNTRLR [Node 002] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:41:39.211 SERIAL « 0x0a00040002044608007fc6 (11 bytes) 18:41:39.211 SERIAL Buffer := 0x010a00040002044608007fc6 (12 bytes) 18:41:39.215 SERIAL » [ACK] (0x06) 18:41:39.215 SERIAL The receive buffer is empty, waiting for the next chunk... 18:41:39.214 CNTRLR [Node 002] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:41:39.229 SERIAL « 0x01 (1 bytes) 18:41:39.230 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:41:39.233 CNTRLR « [Node 002] received wakeup notification 18:41:39.238 DRIVER » [Node 002] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:41:39.231 SERIAL « 0x080004000202840770 (9 bytes) 18:41:39.232 SERIAL Buffer := 0x01080004000202840770 (10 bytes) 18:41:39.233 SERIAL » [ACK] (0x06) 18:41:39.236 SERIAL The receive buffer is empty, waiting for the next chunk... 18:41:39.239 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:41:39.235 CNTRLR [Node 002] The node is now awake. 18:41:39.243 SERIAL « [ACK] (0x06) 18:41:39.243 DRIVER Unexpected ACK received 18:41:39.244 SERIAL The receive buffer is empty, waiting for the next chunk... 18:41:39.250 SERIAL « 0x01 (1 bytes) 18:41:39.250 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:41:39.252 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:41:39.251 SERIAL « 0x04011301e8 (5 bytes) 18:41:39.251 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:41:39.251 SERIAL » [ACK] (0x06) 18:41:39.252 SERIAL The receive buffer is empty, waiting for the next chunk... 18:41:39.266 SERIAL « 0x01 (1 bytes) 18:41:39.267 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:41:39.269 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:41:39.268 SERIAL « 0x0700134a000003a2 (8 bytes) 18:41:39.268 SERIAL Buffer := 0x010700134a000003a2 (9 bytes) 18:41:39.269 SERIAL » [ACK] (0x06) 18:41:39.270 SERIAL The receive buffer is empty, waiting for the next chunk... 18:41:39.270 DRIVER ACK received from node for current transaction. RTT = 32.14 ms 18:41:40.303 CNTRLR [Node 002] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:41:40.804 DRIVER » [Node 002] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:41:40.806 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:41:40.809 SERIAL « [ACK] (0x06) 18:41:40.810 DRIVER ACK received from controller for current transaction 18:41:40.810 SERIAL The receive buffer is empty, waiting for the next chunk... 18:41:40.816 SERIAL « 0x01 (1 bytes) 18:41:40.816 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:41:40.818 SERIAL « 0x04011301e8 (5 bytes) 18:41:40.820 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:41:40.819 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:41:40.820 SERIAL » [ACK] (0x06) 18:41:40.821 SERIAL The receive buffer is empty, waiting for the next chunk... 18:41:40.972 SERIAL « 0x01 (1 bytes) 18:41:40.973 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:41:40.975 SERIAL « 0x0700134a000010b1 (8 bytes) 18:41:40.976 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:41:40.975 SERIAL Buffer := 0x010700134a000010b1 (9 bytes) 18:41:40.976 SERIAL » [ACK] (0x06) 18:41:40.977 SERIAL The receive buffer is empty, waiting for the next chunk... 18:41:40.977 DRIVER ACK received from node for current transaction. RTT = 1739.11 ms 18:41:43.717 CNTRLR [Node 002] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:41:44.218 DRIVER » [Node 002] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:41:44.218 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:41:44.222 SERIAL « [ACK] (0x06) 18:41:44.223 DRIVER ACK received from controller for current transaction 18:41:44.223 SERIAL The receive buffer is empty, waiting for the next chunk... 18:41:44.228 SERIAL « 0x01 (1 bytes) 18:41:44.228 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:41:44.230 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:41:44.230 SERIAL « 0x04011301e8 (5 bytes) 18:41:44.230 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:41:44.230 SERIAL » [ACK] (0x06) 18:41:44.231 SERIAL The receive buffer is empty, waiting for the next chunk... 18:41:44.717 SERIAL « 0x01 (1 bytes) 18:41:44.717 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:41:44.719 SERIAL « 0x0700134a00003293 (8 bytes) 18:41:44.720 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:41:44.720 SERIAL Buffer := 0x010700134a00003293 (9 bytes) 18:41:44.720 SERIAL » [ACK] (0x06) 18:41:44.721 SERIAL The receive buffer is empty, waiting for the next chunk... 18:41:44.721 DRIVER ACK received from node for current transaction. RTT = 5483.36 ms 18:41:49.235 DRIVER The awake timeout for node 2 has elapsed. Assuming it is asleep. 18:41:49.237 CNTRLR [Node 002] The node is now asleep. 18:41:49.239 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:41:49.240 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:43:07.197 SERIAL « 0x01 (1 bytes) 18:43:07.197 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:07.199 SERIAL « 0x09000400050380033a4d (10 bytes) 18:43:07.200 CNTRLR [Node 005] [~] [Battery] level: 58 => 58 [Endpoint 0] 18:43:07.199 SERIAL Buffer := 0x0109000400050380033a4d (11 bytes) 18:43:07.205 SERIAL » [ACK] (0x06) 18:43:07.205 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:07.202 CNTRLR [Node 005] [~] [Battery] isLow: false => false [Endpoint 0] 18:43:07.218 SERIAL « 0x01 (1 bytes) 18:43:07.219 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:07.222 SERIAL « 0x0c0004000506430301420708f8 (13 bytes) 18:43:07.224 CNTRLR [Node 005] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:43:07.223 SERIAL Buffer := 0x010c0004000506430301420708f8 (14 bytes) 18:43:07.225 SERIAL » [ACK] (0x06) 18:43:07.226 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:07.239 SERIAL « 0x01 (1 bytes) 18:43:07.239 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:07.242 CNTRLR [Node 005] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:43:07.241 SERIAL « 0x0a00040005044608007fc1 (11 bytes) 18:43:07.241 SERIAL Buffer := 0x010a00040005044608007fc1 (12 bytes) 18:43:07.246 SERIAL » [ACK] (0x06) 18:43:07.247 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:07.245 CNTRLR [Node 005] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:43:07.263 SERIAL « 0x01 (1 bytes) 18:43:07.264 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:07.268 CNTRLR « [Node 005] received wakeup notification 18:43:07.273 DRIVER » [Node 005] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:43:07.265 SERIAL « 0x080004000502840777 (9 bytes) 18:43:07.266 SERIAL Buffer := 0x01080004000502840777 (10 bytes) 18:43:07.267 SERIAL » [ACK] (0x06) 18:43:07.271 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:07.273 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:43:07.269 CNTRLR [Node 005] The node is now awake. 18:43:07.278 SERIAL « [ACK] (0x06) 18:43:07.279 DRIVER Unexpected ACK received 18:43:07.279 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:07.285 SERIAL « 0x01 (1 bytes) 18:43:07.285 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:07.288 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:43:07.287 SERIAL « 0x04011301e8 (5 bytes) 18:43:07.287 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:43:07.287 SERIAL » [ACK] (0x06) 18:43:07.288 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:07.303 SERIAL « 0x01 (1 bytes) 18:43:07.303 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:07.305 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:43:07.304 SERIAL « 0x07001356000002bf (8 bytes) 18:43:07.305 SERIAL Buffer := 0x0107001356000002bf (9 bytes) 18:43:07.305 SERIAL » [ACK] (0x06) 18:43:07.306 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:07.306 DRIVER ACK received from node for current transaction. RTT = 33.25 ms 18:43:08.340 CNTRLR [Node 005] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:43:08.841 DRIVER » [Node 005] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:43:08.842 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:43:08.844 SERIAL « [ACK] (0x06) 18:43:08.845 DRIVER ACK received from controller for current transaction 18:43:08.845 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:08.851 SERIAL « 0x01 (1 bytes) 18:43:08.852 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:08.853 SERIAL « 0x04011301e8 (5 bytes) 18:43:08.854 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:43:08.854 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:43:08.854 SERIAL » [ACK] (0x06) 18:43:08.856 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:08.868 SERIAL « 0x01 (1 bytes) 18:43:08.868 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:08.870 SERIAL « 0x07001356000002bf (8 bytes) 18:43:08.871 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:43:08.872 DRIVER ACK received from node for current transaction. RTT = 1599.25 ms 18:43:08.870 SERIAL Buffer := 0x0107001356000002bf (9 bytes) 18:43:08.871 SERIAL » [ACK] (0x06) 18:43:08.873 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:11.472 CNTRLR [Node 005] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:43:11.972 DRIVER » [Node 005] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:43:11.973 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:43:11.977 SERIAL « [ACK] (0x06) 18:43:11.978 DRIVER ACK received from controller for current transaction 18:43:11.978 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:11.984 SERIAL « 0x01 (1 bytes) 18:43:11.984 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:11.986 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:43:11.985 SERIAL « 0x04011301e8 (5 bytes) 18:43:11.986 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:43:11.986 SERIAL » [ACK] (0x06) 18:43:11.989 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:12.000 SERIAL « 0x01 (1 bytes) 18:43:12.002 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:12.004 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:43:12.003 SERIAL « 0x07001356000002bf (8 bytes) 18:43:12.003 SERIAL Buffer := 0x0107001356000002bf (9 bytes) 18:43:12.003 SERIAL » [ACK] (0x06) 18:43:12.005 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:12.004 DRIVER ACK received from node for current transaction. RTT = 4731.93 ms 18:43:17.270 DRIVER The awake timeout for node 5 has elapsed. Assuming it is asleep. 18:43:17.271 CNTRLR [Node 005] The node is now asleep. 18:43:17.273 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:43:17.273 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:43:24.569 SERIAL « 0x01 (1 bytes) 18:43:24.569 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:24.570 SERIAL « 0x160049840410040804804681728f75438684ef46818f11 (23 bytes) 18:43:24.572 CNTRLR « [Node 004] Received updated node info 18:43:24.574 DRIVER » [Node 004] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 139 └─[ThermostatSetpointCCGet] payload: 0x07 18:43:24.571 SERIAL Buffer := 0x01160049840410040804804681728f75438684ef46818f11 (24 bytes) 18:43:24.571 SERIAL » [ACK] (0x06) 18:43:24.573 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:24.575 SERIAL » 0x010a00130403430207258b09 (12 bytes) 18:43:24.572 CNTRLR [Node 004] The node is now awake. 18:43:24.578 SERIAL « [ACK] (0x06) 18:43:24.579 DRIVER Unexpected ACK received 18:43:24.580 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:24.586 SERIAL « 0x0104011301e8 (6 bytes) 18:43:24.588 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:43:24.587 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:43:24.588 SERIAL » [ACK] (0x06) 18:43:24.589 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:24.602 SERIAL « 0x01 (1 bytes) 18:43:24.602 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:24.604 SERIAL « 0x0700138b00000262 (8 bytes) 18:43:24.605 DRIVER « [REQ] [SendData] [confirmation] callbackId: 139 transmitStatus: OK 18:43:24.604 SERIAL Buffer := 0x010700138b00000262 (9 bytes) 18:43:24.604 SERIAL » [ACK] (0x06) 18:43:24.606 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:24.605 DRIVER ACK received from node for current transaction. RTT = 31.24 ms 18:43:25.638 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:43:26.138 DRIVER » [Node 004] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 139 └─[ThermostatSetpointCCGet] payload: 0x07 18:43:26.139 SERIAL » 0x010a00130403430207258b09 (12 bytes) 18:43:26.142 SERIAL « [ACK] (0x06) 18:43:26.143 DRIVER ACK received from controller for current transaction 18:43:26.143 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:26.149 SERIAL « 0x01 (1 bytes) 18:43:26.149 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:26.151 SERIAL « 0x04011301e8 (5 bytes) 18:43:26.152 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:43:26.151 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:43:26.152 SERIAL » [ACK] (0x06) 18:43:26.152 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:26.166 SERIAL « 0x01 (1 bytes) 18:43:26.166 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:26.170 DRIVER « [REQ] [SendData] [confirmation] callbackId: 139 transmitStatus: OK 18:43:26.170 DRIVER ACK received from node for current transaction. RTT = 1596.00 ms 18:43:26.168 SERIAL « 0x0700138b00000363 (8 bytes) 18:43:26.168 SERIAL Buffer := 0x010700138b00000363 (9 bytes) 18:43:26.169 SERIAL » [ACK] (0x06) 18:43:26.171 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:28.768 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:43:29.268 DRIVER » [Node 004] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 139 └─[ThermostatSetpointCCGet] payload: 0x07 18:43:29.269 SERIAL » 0x010a00130403430207258b09 (12 bytes) 18:43:29.273 SERIAL « [ACK] (0x06) 18:43:29.273 DRIVER ACK received from controller for current transaction 18:43:29.274 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:29.279 SERIAL « 0x01 (1 bytes) 18:43:29.280 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:29.282 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:43:29.281 SERIAL « 0x04011301e8 (5 bytes) 18:43:29.281 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:43:29.282 SERIAL » [ACK] (0x06) 18:43:29.283 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:29.296 SERIAL « 0x01 (1 bytes) 18:43:29.297 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:29.300 SERIAL « 0x0700138b00000363 (8 bytes) 18:43:29.301 DRIVER « [REQ] [SendData] [confirmation] callbackId: 139 transmitStatus: OK 18:43:29.300 SERIAL Buffer := 0x010700138b00000363 (9 bytes) 18:43:29.301 SERIAL » [ACK] (0x06) 18:43:29.303 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:29.302 DRIVER ACK received from node for current transaction. RTT = 4727.87 ms 18:43:34.574 DRIVER The awake timeout for node 4 has elapsed. Assuming it is asleep. 18:43:34.574 CNTRLR [Node 004] The node is now asleep. 18:43:34.576 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:43:34.576 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:43:46.763 SERIAL « 0x01 (1 bytes) 18:43:46.764 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:46.765 SERIAL « 0x0900040004038003285e (10 bytes) 18:43:46.769 CNTRLR [Node 004] [~] [Battery] level: 40 => 40 [Endpoint 0] 18:43:46.766 SERIAL Buffer := 0x010900040004038003285e (11 bytes) 18:43:46.772 SERIAL » [ACK] (0x06) 18:43:46.774 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:46.771 CNTRLR [Node 004] [~] [Battery] isLow: false => false [Endpoint 0] 18:43:46.785 SERIAL « 0x01 (1 bytes) 18:43:46.785 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:46.788 CNTRLR [Node 004] [~] [Thermostat Setpoint] setpoint[1]: 5 => 5 [Endpoint 0] 18:43:46.787 SERIAL « 0x0c00040004064303014201f403 (13 bytes) 18:43:46.787 SERIAL Buffer := 0x010c00040004064303014201f403 (14 bytes) 18:43:46.790 SERIAL » [ACK] (0x06) 18:43:46.791 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:46.806 SERIAL « 0x01 (1 bytes) 18:43:46.806 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:46.808 SERIAL « 0x0a00040004044608007fc0 (11 bytes) 18:43:46.809 CNTRLR [Node 004] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:43:46.808 SERIAL Buffer := 0x010a00040004044608007fc0 (12 bytes) 18:43:46.812 SERIAL » [ACK] (0x06) 18:43:46.813 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:46.811 CNTRLR [Node 004] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:43:46.825 SERIAL « 0x01 (1 bytes) 18:43:46.826 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:46.828 SERIAL « 0x080004000402840776 (9 bytes) 18:43:46.830 CNTRLR « [Node 004] received wakeup notification 18:43:46.833 DRIVER » [Node 004] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 139 └─[ThermostatSetpointCCGet] payload: 0x07 18:43:46.828 SERIAL Buffer := 0x01080004000402840776 (10 bytes) 18:43:46.829 SERIAL » [ACK] (0x06) 18:43:46.831 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:46.833 SERIAL » 0x010a00130403430207258b09 (12 bytes) 18:43:46.830 CNTRLR [Node 004] The node is now awake. 18:43:46.838 SERIAL « [ACK] (0x06) 18:43:46.838 DRIVER Unexpected ACK received 18:43:46.839 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:46.844 SERIAL « 0x01 (1 bytes) 18:43:46.844 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:46.845 SERIAL « 0x04011301e8 (5 bytes) 18:43:46.846 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:43:46.846 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:43:46.846 SERIAL » [ACK] (0x06) 18:43:46.847 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:46.861 SERIAL « 0x01 (1 bytes) 18:43:46.861 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:46.865 SERIAL « 0x0700138b00000262 (8 bytes) 18:43:46.866 DRIVER « [REQ] [SendData] [confirmation] callbackId: 139 transmitStatus: OK 18:43:46.866 SERIAL Buffer := 0x010700138b00000262 (9 bytes) 18:43:46.866 SERIAL » [ACK] (0x06) 18:43:46.868 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:46.867 DRIVER ACK received from node for current transaction. RTT = 34.67 ms 18:43:47.903 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:43:48.403 DRIVER » [Node 004] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 139 └─[ThermostatSetpointCCGet] payload: 0x07 18:43:48.404 SERIAL » 0x010a00130403430207258b09 (12 bytes) 18:43:48.408 SERIAL « [ACK] (0x06) 18:43:48.409 DRIVER ACK received from controller for current transaction 18:43:48.409 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:48.415 SERIAL « 0x01 (1 bytes) 18:43:48.415 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:48.417 SERIAL « 0x04011301e8 (5 bytes) 18:43:48.418 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:43:48.417 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:43:48.418 SERIAL » [ACK] (0x06) 18:43:48.421 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:48.432 SERIAL « 0x01 (1 bytes) 18:43:48.432 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:48.434 SERIAL « 0x0700138b00000262 (8 bytes) 18:43:48.435 DRIVER « [REQ] [SendData] [confirmation] callbackId: 139 transmitStatus: OK 18:43:48.434 SERIAL Buffer := 0x010700138b00000262 (9 bytes) 18:43:48.434 SERIAL » [ACK] (0x06) 18:43:48.436 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:48.435 DRIVER ACK received from node for current transaction. RTT = 1603.04 ms 18:43:51.039 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:43:51.541 DRIVER » [Node 004] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 139 └─[ThermostatSetpointCCGet] payload: 0x07 18:43:51.541 SERIAL » 0x010a00130403430207258b09 (12 bytes) 18:43:51.545 SERIAL « [ACK] (0x06) 18:43:51.546 DRIVER ACK received from controller for current transaction 18:43:51.546 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:51.552 SERIAL « 0x01 (1 bytes) 18:43:51.552 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:51.554 SERIAL « 0x04011301e8 (5 bytes) 18:43:51.555 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:43:51.554 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:43:51.555 SERIAL » [ACK] (0x06) 18:43:51.556 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:51.569 SERIAL « 0x01 (1 bytes) 18:43:51.569 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:43:51.571 SERIAL « 0x0700138b00000262 (8 bytes) 18:43:51.572 DRIVER « [REQ] [SendData] [confirmation] callbackId: 139 transmitStatus: OK 18:43:51.572 SERIAL Buffer := 0x010700138b00000262 (9 bytes) 18:43:51.572 SERIAL » [ACK] (0x06) 18:43:51.573 SERIAL The receive buffer is empty, waiting for the next chunk... 18:43:51.573 DRIVER ACK received from node for current transaction. RTT = 4740.76 ms 18:43:56.832 DRIVER The awake timeout for node 4 has elapsed. Assuming it is asleep. 18:43:56.832 CNTRLR [Node 004] The node is now asleep. 18:43:56.833 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:43:56.834 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:44:02.047 SERIAL « 0x01 (1 bytes) 18:44:02.051 CNTRLR [Node 006] [~] [Battery] level: 80 => 80 [Endpoint 0] 18:44:02.048 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:44:02.049 SERIAL « 0x09000400060380035024 (10 bytes) 18:44:02.049 SERIAL Buffer := 0x0109000400060380035024 (11 bytes) 18:44:02.057 SERIAL » [ACK] (0x06) 18:44:02.057 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:02.055 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 0] 18:44:02.072 SERIAL « 0x01 (1 bytes) 18:44:02.073 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:44:02.077 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpoint[1]: 4 => 4 [Endpoint 0] 18:44:02.075 SERIAL « 0x0c000400060643030142019065 (13 bytes) 18:44:02.076 SERIAL Buffer := 0x010c000400060643030142019065 (14 bytes) 18:44:02.078 SERIAL » [ACK] (0x06) 18:44:02.079 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:02.089 SERIAL « 0x01 (1 bytes) 18:44:02.089 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:44:02.092 CNTRLR [Node 006] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:44:02.090 SERIAL « 0x0a00040006044608007fc2 (11 bytes) 18:44:02.090 SERIAL Buffer := 0x010a00040006044608007fc2 (12 bytes) 18:44:02.096 SERIAL » [ACK] (0x06) 18:44:02.098 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:02.095 CNTRLR [Node 006] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:44:02.119 SERIAL « 0x01080004000602840774 (10 bytes) 18:44:02.121 CNTRLR « [Node 006] received wakeup notification 18:44:02.125 DRIVER » [Node 006] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:44:02.120 SERIAL Buffer := 0x01080004000602840774 (10 bytes) 18:44:02.120 SERIAL » [ACK] (0x06) 18:44:02.123 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:02.126 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:44:02.122 CNTRLR [Node 006] The node is now awake. 18:44:02.129 SERIAL « [ACK] (0x06) 18:44:02.130 DRIVER Unexpected ACK received 18:44:02.131 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:02.136 SERIAL « 0x01 (1 bytes) 18:44:02.136 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:44:02.139 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:44:02.137 SERIAL « 0x04011301e8 (5 bytes) 18:44:02.138 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:44:02.138 SERIAL » [ACK] (0x06) 18:44:02.139 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:02.153 SERIAL « 0x01 (1 bytes) 18:44:02.153 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:44:02.155 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:44:02.154 SERIAL « 0x0700136e00000287 (8 bytes) 18:44:02.154 SERIAL Buffer := 0x010700136e00000287 (9 bytes) 18:44:02.155 SERIAL » [ACK] (0x06) 18:44:02.157 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:02.156 DRIVER ACK received from node for current transaction. RTT = 31.27 ms 18:44:03.188 CNTRLR [Node 006] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:44:03.688 DRIVER » [Node 006] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:44:03.689 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:44:03.693 SERIAL « [ACK] (0x06) 18:44:03.693 DRIVER ACK received from controller for current transaction 18:44:03.694 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:03.699 SERIAL « 0x01 (1 bytes) 18:44:03.699 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:44:03.703 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:44:03.702 SERIAL « 0x04011301e8 (5 bytes) 18:44:03.702 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:44:03.702 SERIAL » [ACK] (0x06) 18:44:03.704 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:03.717 SERIAL « 0x01 (1 bytes) 18:44:03.718 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:44:03.720 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:44:03.719 SERIAL « 0x0700136e00000386 (8 bytes) 18:44:03.719 SERIAL Buffer := 0x010700136e00000386 (9 bytes) 18:44:03.720 SERIAL » [ACK] (0x06) 18:44:03.721 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:03.720 DRIVER ACK received from node for current transaction. RTT = 1595.64 ms 18:44:06.317 CNTRLR [Node 006] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:44:06.818 DRIVER » [Node 006] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:44:06.818 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:44:06.822 SERIAL « [ACK] (0x06) 18:44:06.823 DRIVER ACK received from controller for current transaction 18:44:06.823 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:06.829 SERIAL « 0x01 (1 bytes) 18:44:06.830 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:44:06.831 SERIAL « 0x04011301e8 (5 bytes) 18:44:06.832 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:44:06.832 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:44:06.832 SERIAL » [ACK] (0x06) 18:44:06.835 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:06.846 SERIAL « 0x01 (1 bytes) 18:44:06.846 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:44:06.848 SERIAL « 0x0700136e00000287 (8 bytes) 18:44:06.849 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:44:06.848 SERIAL Buffer := 0x010700136e00000287 (9 bytes) 18:44:06.849 SERIAL » [ACK] (0x06) 18:44:06.850 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:06.850 DRIVER ACK received from node for current transaction. RTT = 4725.14 ms 18:44:12.123 DRIVER The awake timeout for node 6 has elapsed. Assuming it is asleep. 18:44:12.124 CNTRLR [Node 006] The node is now asleep. 18:44:12.125 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:44:12.126 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:44:52.266 SERIAL « 0x01 (1 bytes) 18:44:52.267 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:44:52.269 SERIAL « 0x09000400030380033342 (10 bytes) 18:44:52.271 CNTRLR [Node 003] [~] [Battery] level: 51 => 51 [Endpoint 0] 18:44:52.269 SERIAL Buffer := 0x0109000400030380033342 (11 bytes) 18:44:52.274 SERIAL » [ACK] (0x06) 18:44:52.276 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:52.272 CNTRLR [Node 003] [~] [Battery] isLow: false => false [Endpoint 0] 18:44:52.287 SERIAL « 0x01 (1 bytes) 18:44:52.289 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:44:52.292 CNTRLR [Node 003] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:44:52.290 SERIAL « 0x0c0004000306430301420708fe (13 bytes) 18:44:52.290 SERIAL Buffer := 0x010c0004000306430301420708fe (14 bytes) 18:44:52.294 SERIAL » [ACK] (0x06) 18:44:52.295 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:52.308 SERIAL « 0x01 (1 bytes) 18:44:52.309 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:44:52.310 SERIAL « 0x0a00040003044608007fc7 (11 bytes) 18:44:52.312 CNTRLR [Node 003] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:44:52.310 SERIAL Buffer := 0x010a00040003044608007fc7 (12 bytes) 18:44:52.315 SERIAL » [ACK] (0x06) 18:44:52.315 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:52.313 CNTRLR [Node 003] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:44:52.327 SERIAL « 0x01 (1 bytes) 18:44:52.328 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:44:52.330 SERIAL « 0x080004000302840771 (9 bytes) 18:44:52.332 CNTRLR « [Node 003] received wakeup notification 18:44:52.338 DRIVER » [Node 003] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 122 └─[ThermostatSetpointCCGet] payload: 0x02 18:44:52.330 SERIAL Buffer := 0x01080004000302840771 (10 bytes) 18:44:52.332 SERIAL » [ACK] (0x06) 18:44:52.337 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:52.338 SERIAL » 0x010a00130303430202257afa (12 bytes) 18:44:52.333 CNTRLR [Node 003] The node is now awake. 18:44:52.345 SERIAL « [ACK] (0x06) 18:44:52.346 DRIVER Unexpected ACK received 18:44:52.346 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:52.348 SERIAL « 0x01 (1 bytes) 18:44:52.349 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:44:52.351 SERIAL « 0x04011301e8 (5 bytes) 18:44:52.352 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:44:52.351 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:44:52.352 SERIAL » [ACK] (0x06) 18:44:52.353 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:52.365 SERIAL « 0x01 (1 bytes) 18:44:52.366 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:44:52.367 SERIAL « 0x0700137a00000293 (8 bytes) 18:44:52.369 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 18:44:52.368 SERIAL Buffer := 0x010700137a00000293 (9 bytes) 18:44:52.368 SERIAL » [ACK] (0x06) 18:44:52.370 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:52.369 DRIVER ACK received from node for current transaction. RTT = 31.92 ms 18:44:53.401 CNTRLR [Node 003] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:44:53.901 DRIVER » [Node 003] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 122 └─[ThermostatSetpointCCGet] payload: 0x02 18:44:53.902 SERIAL » 0x010a00130303430202257afa (12 bytes) 18:44:53.906 SERIAL « [ACK] (0x06) 18:44:53.906 DRIVER ACK received from controller for current transaction 18:44:53.906 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:53.912 SERIAL « 0x01 (1 bytes) 18:44:53.912 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:44:53.914 SERIAL « 0x04011301e8 (5 bytes) 18:44:53.915 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:44:53.914 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:44:53.915 SERIAL » [ACK] (0x06) 18:44:53.915 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:53.929 SERIAL « 0x01 (1 bytes) 18:44:53.929 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:44:53.930 SERIAL « 0x0700137a00000293 (8 bytes) 18:44:53.932 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 18:44:53.931 SERIAL Buffer := 0x010700137a00000293 (9 bytes) 18:44:53.931 SERIAL » [ACK] (0x06) 18:44:53.933 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:53.932 DRIVER ACK received from node for current transaction. RTT = 1594.76 ms 18:44:56.527 CNTRLR [Node 003] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:44:57.027 DRIVER » [Node 003] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 122 └─[ThermostatSetpointCCGet] payload: 0x02 18:44:57.028 SERIAL » 0x010a00130303430202257afa (12 bytes) 18:44:57.033 SERIAL « [ACK] (0x06) 18:44:57.033 DRIVER ACK received from controller for current transaction 18:44:57.033 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:57.039 SERIAL « 0x01 (1 bytes) 18:44:57.039 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:44:57.041 SERIAL « 0x04011301e8 (5 bytes) 18:44:57.042 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:44:57.041 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:44:57.042 SERIAL » [ACK] (0x06) 18:44:57.042 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:57.056 SERIAL « 0x01 (1 bytes) 18:44:57.056 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:44:57.058 SERIAL « 0x0700137a00000392 (8 bytes) 18:44:57.059 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 18:44:57.058 SERIAL Buffer := 0x010700137a00000392 (9 bytes) 18:44:57.058 SERIAL » [ACK] (0x06) 18:44:57.060 SERIAL The receive buffer is empty, waiting for the next chunk... 18:44:57.059 DRIVER ACK received from node for current transaction. RTT = 4721.67 ms 18:45:02.335 DRIVER The awake timeout for node 3 has elapsed. Assuming it is asleep. 18:45:02.336 CNTRLR [Node 003] The node is now asleep. 18:45:02.337 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:45:02.338 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:45:37.242 SERIAL « 0x01 (1 bytes) 18:45:37.242 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:45:37.244 SERIAL « 0x09000400080380034832 (10 bytes) 18:45:37.246 CNTRLR [Node 008] [~] [Battery] level: 72 => 72 [Endpoint 0] 18:45:37.245 SERIAL Buffer := 0x0109000400080380034832 (11 bytes) 18:45:37.248 SERIAL » [ACK] (0x06) 18:45:37.249 SERIAL The receive buffer is empty, waiting for the next chunk... 18:45:37.247 CNTRLR [Node 008] [~] [Battery] isLow: false => false [Endpoint 0] 18:45:37.265 SERIAL « 0x01 (1 bytes) 18:45:37.266 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:45:37.268 CNTRLR [Node 008] [~] [Thermostat Setpoint] setpoint[1]: 4.5 => 4.5 [Endpoint 0] 18:45:37.267 SERIAL « 0x0c00040008064303014201c239 (13 bytes) 18:45:37.267 SERIAL Buffer := 0x010c00040008064303014201c239 (14 bytes) 18:45:37.270 SERIAL » [ACK] (0x06) 18:45:37.270 SERIAL The receive buffer is empty, waiting for the next chunk... 18:45:37.283 SERIAL « 0x01 (1 bytes) 18:45:37.283 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:45:37.285 SERIAL « 0x0a00040008044608007fcc (11 bytes) 18:45:37.286 CNTRLR [Node 008] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:45:37.285 SERIAL Buffer := 0x010a00040008044608007fcc (12 bytes) 18:45:37.289 SERIAL » [ACK] (0x06) 18:45:37.290 SERIAL The receive buffer is empty, waiting for the next chunk... 18:45:37.288 CNTRLR [Node 008] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:45:37.305 SERIAL « 0x01 (1 bytes) 18:45:37.305 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:45:37.307 SERIAL « 0x0c000400080631050142079f16 (13 bytes) 18:45:37.309 CNTRLR [Node 008] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 18:45:37.308 SERIAL Buffer := 0x010c000400080631050142079f16 (14 bytes) 18:45:37.312 SERIAL » [ACK] (0x06) 18:45:37.313 SERIAL The receive buffer is empty, waiting for the next chunk... 18:45:37.311 CNTRLR [Node 008] [~] [Multilevel Sensor] Air temperature: 19.48 => 19.5 [Endpoint 0] 1 18:45:37.324 SERIAL « 0x01 (1 bytes) 18:45:37.325 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:45:37.327 CNTRLR « [Node 008] received wakeup notification 18:45:37.329 DRIVER » [Node 008] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:45:37.325 SERIAL « 0x08000400080284077a (9 bytes) 18:45:37.326 SERIAL Buffer := 0x0108000400080284077a (10 bytes) 18:45:37.326 SERIAL » [ACK] (0x06) 18:45:37.329 SERIAL The receive buffer is empty, waiting for the next chunk... 18:45:37.330 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:45:37.327 CNTRLR [Node 008] The node is now awake. 18:45:37.334 SERIAL « [ACK] (0x06) 18:45:37.335 DRIVER Unexpected ACK received 18:45:37.335 SERIAL The receive buffer is empty, waiting for the next chunk... 18:45:37.341 SERIAL « 0x01 (1 bytes) 18:45:37.341 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:45:37.343 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:45:37.342 SERIAL « 0x04011301e8 (5 bytes) 18:45:37.342 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:45:37.342 SERIAL » [ACK] (0x06) 18:45:37.343 SERIAL The receive buffer is empty, waiting for the next chunk... 18:45:37.357 SERIAL « 0x01 (1 bytes) 18:45:37.358 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:45:37.360 SERIAL « 0x0700138a00000362 (8 bytes) 18:45:37.361 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:45:37.360 SERIAL Buffer := 0x010700138a00000362 (9 bytes) 18:45:37.360 SERIAL » [ACK] (0x06) 18:45:37.362 SERIAL The receive buffer is empty, waiting for the next chunk... 18:45:37.361 DRIVER ACK received from node for current transaction. RTT = 32.07 ms 18:45:38.395 CNTRLR [Node 008] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:45:38.896 DRIVER » [Node 008] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:45:38.896 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:45:38.902 SERIAL « [ACK] (0x06) 18:45:38.902 DRIVER ACK received from controller for current transaction 18:45:38.903 SERIAL The receive buffer is empty, waiting for the next chunk... 18:45:38.907 SERIAL « 0x01 (1 bytes) 18:45:38.908 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:45:38.909 SERIAL « 0x04011301e8 (5 bytes) 18:45:38.911 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:45:38.910 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:45:38.910 SERIAL » [ACK] (0x06) 18:45:38.911 SERIAL The receive buffer is empty, waiting for the next chunk... 18:45:38.925 SERIAL « 0x01 (1 bytes) 18:45:38.925 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:45:38.927 SERIAL « 0x0700138a00000263 (8 bytes) 18:45:38.929 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:45:38.929 DRIVER ACK received from node for current transaction. RTT = 1599.93 ms 18:45:38.928 SERIAL Buffer := 0x010700138a00000263 (9 bytes) 18:45:38.928 SERIAL » [ACK] (0x06) 18:45:38.930 SERIAL The receive buffer is empty, waiting for the next chunk... 18:45:41.529 CNTRLR [Node 008] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:45:42.031 DRIVER » [Node 008] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:45:42.031 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:45:42.035 SERIAL « [ACK] (0x06) 18:45:42.036 DRIVER ACK received from controller for current transaction 18:45:42.036 SERIAL The receive buffer is empty, waiting for the next chunk... 18:45:42.041 SERIAL « 0x01 (1 bytes) 18:45:42.042 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:45:42.044 SERIAL « 0x04011301e8 (5 bytes) 18:45:42.045 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:45:42.044 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:45:42.045 SERIAL » [ACK] (0x06) 18:45:42.046 SERIAL The receive buffer is empty, waiting for the next chunk... 18:45:42.058 SERIAL « 0x01 (1 bytes) 18:45:42.059 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:45:42.060 SERIAL « 0x0700138a00000263 (8 bytes) 18:45:42.061 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:45:42.061 SERIAL Buffer := 0x010700138a00000263 (9 bytes) 18:45:42.061 SERIAL » [ACK] (0x06) 18:45:42.062 SERIAL The receive buffer is empty, waiting for the next chunk... 18:45:42.062 DRIVER ACK received from node for current transaction. RTT = 4732.55 ms 18:45:47.328 DRIVER The awake timeout for node 8 has elapsed. Assuming it is asleep. 18:45:47.328 CNTRLR [Node 008] The node is now asleep. 18:45:47.330 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:45:47.332 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:46:30.654 SERIAL « 0x01 (1 bytes) 18:46:30.655 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:46:30.659 CNTRLR [Node 002] [~] [Battery] level: 80 => 80 [Endpoint 0] 18:46:30.656 SERIAL « 0x09000400020380035020 (10 bytes) 18:46:30.657 SERIAL Buffer := 0x0109000400020380035020 (11 bytes) 18:46:30.666 SERIAL » [ACK] (0x06) 18:46:30.675 SERIAL The receive buffer is empty, waiting for the next chunk... 18:46:30.663 CNTRLR [Node 002] [~] [Battery] isLow: false => false [Endpoint 0] 18:46:30.983 SERIAL « 0x01 (1 bytes) 18:46:30.984 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:46:30.988 CNTRLR [Node 002] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:46:30.985 SERIAL « 0x0c0004000206430301420708ff (13 bytes) 18:46:30.986 SERIAL Buffer := 0x010c0004000206430301420708ff (14 bytes) 18:46:30.990 SERIAL » [ACK] (0x06) 18:46:30.991 SERIAL The receive buffer is empty, waiting for the next chunk... 18:46:31.035 SERIAL « 0x01 (1 bytes) 18:46:31.035 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:46:31.040 CNTRLR [Node 002] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:46:31.038 SERIAL « 0x0a00040002044608007fc6 (11 bytes) 18:46:31.038 SERIAL Buffer := 0x010a00040002044608007fc6 (12 bytes) 18:46:31.044 SERIAL » [ACK] (0x06) 18:46:31.045 SERIAL The receive buffer is empty, waiting for the next chunk... 18:46:31.042 CNTRLR [Node 002] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:46:31.112 SERIAL « 0x01 (1 bytes) 18:46:31.112 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:46:31.114 SERIAL « 0x080004000202840770 (9 bytes) 18:46:31.115 CNTRLR « [Node 002] received wakeup notification 18:46:31.119 DRIVER » [Node 002] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:46:31.114 SERIAL Buffer := 0x01080004000202840770 (10 bytes) 18:46:31.115 SERIAL » [ACK] (0x06) 18:46:31.118 SERIAL The receive buffer is empty, waiting for the next chunk... 18:46:31.122 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:46:31.116 CNTRLR [Node 002] The node is now awake. 18:46:31.126 SERIAL « [ACK] (0x06) 18:46:31.126 DRIVER Unexpected ACK received 18:46:31.127 SERIAL The receive buffer is empty, waiting for the next chunk... 18:46:31.132 SERIAL « 0x01 (1 bytes) 18:46:31.133 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:46:31.135 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:46:31.134 SERIAL « 0x04011301e8 (5 bytes) 18:46:31.135 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:46:31.135 SERIAL » [ACK] (0x06) 18:46:31.136 SERIAL The receive buffer is empty, waiting for the next chunk... 18:46:31.263 SERIAL « 0x01 (1 bytes) 18:46:31.263 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:46:31.265 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:46:31.264 SERIAL « 0x0700134a00000dac (8 bytes) 18:46:31.264 SERIAL Buffer := 0x010700134a00000dac (9 bytes) 18:46:31.264 SERIAL » [ACK] (0x06) 18:46:31.266 SERIAL The receive buffer is empty, waiting for the next chunk... 18:46:31.265 DRIVER ACK received from node for current transaction. RTT = 146.57 ms 18:46:32.412 CNTRLR [Node 002] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:46:32.723 DRIVER Timeout occured waiting for ACK - scheduling transmission attempt (3/3) in 110 0 ms... 18:46:32.912 DRIVER » [Node 002] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:46:32.913 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:46:32.916 SERIAL « [ACK] (0x06) 18:46:32.917 DRIVER ACK received from controller for current transaction 18:46:32.917 SERIAL The receive buffer is empty, waiting for the next chunk... 18:46:32.923 SERIAL « 0x01 (1 bytes) 18:46:32.924 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:46:32.925 SERIAL « 0x04011301e8 (5 bytes) 18:46:32.927 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:46:32.926 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:46:32.926 SERIAL » [ACK] (0x06) 18:46:32.928 SERIAL The receive buffer is empty, waiting for the next chunk... 18:46:32.969 SERIAL « 0x01 (1 bytes) 18:46:32.969 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:46:32.971 SERIAL « 0x0700134a000005a4 (8 bytes) 18:46:32.972 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:46:32.972 SERIAL Buffer := 0x010700134a000005a4 (9 bytes) 18:46:32.972 SERIAL » [ACK] (0x06) 18:46:32.973 SERIAL The receive buffer is empty, waiting for the next chunk... 18:46:32.973 DRIVER ACK received from node for current transaction. RTT = 1854.17 ms 18:46:33.824 DRIVER » [Node 002] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:46:33.825 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:46:33.828 SERIAL « [ACK] (0x06) 18:46:33.829 DRIVER ACK received from controller for current transaction 18:46:33.831 SERIAL The receive buffer is empty, waiting for the next chunk... 18:46:33.836 SERIAL « 0x01 (1 bytes) 18:46:33.836 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:46:33.838 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:46:33.837 SERIAL « 0x04011301e8 (5 bytes) 18:46:33.837 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:46:33.838 SERIAL » [ACK] (0x06) 18:46:33.839 SERIAL The receive buffer is empty, waiting for the next chunk... 18:46:33.881 SERIAL « 0x01 (1 bytes) 18:46:33.881 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:46:33.883 SERIAL « 0x0700134a000005a4 (8 bytes) 18:46:33.884 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:46:33.884 SERIAL Buffer := 0x010700134a000005a4 (9 bytes) 18:46:33.884 SERIAL » [ACK] (0x06) 18:46:33.885 SERIAL The receive buffer is empty, waiting for the next chunk... 18:46:33.885 DRIVER ACK received from node for current transaction. RTT = 2766.09 ms 18:46:37.653 CNTRLR [Node 002] The node did not respond to the current transaction after 3 attempt s. It is probably asleep, moving its messages to the wakeup queue. 18:46:37.653 CNTRLR [Node 002] The node is now asleep. 18:46:37.654 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:46:37.655 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:48:00.483 SERIAL « 0x0109000400050380033a4d (11 bytes) 18:48:00.486 CNTRLR [Node 005] [~] [Battery] level: 58 => 58 [Endpoint 0] 18:48:00.484 SERIAL Buffer := 0x0109000400050380033a4d (11 bytes) 18:48:00.520 SERIAL » [ACK] (0x06) 18:48:00.521 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:00.514 CNTRLR [Node 005] [~] [Battery] isLow: false => false [Endpoint 0] 18:48:00.526 SERIAL « 0x010c0004000506430301420708f8 (14 bytes) 18:48:00.532 CNTRLR [Node 005] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:48:00.529 SERIAL Buffer := 0x010c0004000506430301420708f8 (14 bytes) 18:48:00.535 SERIAL » [ACK] (0x06) 18:48:00.538 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:00.541 SERIAL « 0x010a00040005044608007fc1 (12 bytes) 18:48:00.545 CNTRLR [Node 005] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:48:00.542 SERIAL Buffer := 0x010a00040005044608007fc1 (12 bytes) 18:48:00.557 SERIAL » [ACK] (0x06) 18:48:00.560 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:00.549 CNTRLR [Node 005] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:48:00.569 SERIAL « 0x01 (1 bytes) 18:48:00.569 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:00.576 CNTRLR « [Node 005] received wakeup notification 18:48:00.579 DRIVER » [Node 005] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:48:00.570 SERIAL « 0x080004000502840777 (9 bytes) 18:48:00.572 SERIAL Buffer := 0x01080004000502840777 (10 bytes) 18:48:00.575 SERIAL » [ACK] (0x06) 18:48:00.578 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:00.579 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:48:00.576 CNTRLR [Node 005] The node is now awake. 18:48:00.585 SERIAL « [ACK] (0x06) 18:48:00.586 DRIVER Unexpected ACK received 18:48:00.587 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:00.593 SERIAL « 0x01 (1 bytes) 18:48:00.595 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:00.598 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:48:00.597 SERIAL « 0x04011301e8 (5 bytes) 18:48:00.597 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:48:00.597 SERIAL » [ACK] (0x06) 18:48:00.600 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:00.609 SERIAL « 0x01 (1 bytes) 18:48:00.610 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:00.612 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:48:00.611 SERIAL « 0x07001356000003be (8 bytes) 18:48:00.611 SERIAL Buffer := 0x0107001356000003be (9 bytes) 18:48:00.612 SERIAL » [ACK] (0x06) 18:48:00.614 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:00.613 DRIVER ACK received from node for current transaction. RTT = 34.56 ms 18:48:01.648 CNTRLR [Node 005] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:48:02.149 DRIVER » [Node 005] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:48:02.149 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:48:02.153 SERIAL « [ACK] (0x06) 18:48:02.154 DRIVER ACK received from controller for current transaction 18:48:02.154 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:02.160 SERIAL « 0x01 (1 bytes) 18:48:02.160 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:02.162 SERIAL « 0x04011301e8 (5 bytes) 18:48:02.163 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:48:02.163 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:48:02.163 SERIAL » [ACK] (0x06) 18:48:02.165 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:02.177 SERIAL « 0x01 (1 bytes) 18:48:02.177 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:02.179 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:48:02.178 SERIAL « 0x07001356000003be (8 bytes) 18:48:02.178 SERIAL Buffer := 0x0107001356000003be (9 bytes) 18:48:02.179 SERIAL » [ACK] (0x06) 18:48:02.180 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:02.180 DRIVER ACK received from node for current transaction. RTT = 1601.42 ms 18:48:04.783 CNTRLR [Node 005] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:48:05.284 DRIVER » [Node 005] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:48:05.285 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:48:05.289 SERIAL « [ACK] (0x06) 18:48:05.289 DRIVER ACK received from controller for current transaction 18:48:05.289 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:05.296 SERIAL « 0x01 (1 bytes) 18:48:05.296 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:05.298 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:48:05.297 SERIAL « 0x04011301e8 (5 bytes) 18:48:05.297 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:48:05.297 SERIAL » [ACK] (0x06) 18:48:05.298 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:05.312 SERIAL « 0x01 (1 bytes) 18:48:05.312 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:05.314 SERIAL « 0x07001356000002bf (8 bytes) 18:48:05.315 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:48:05.315 SERIAL Buffer := 0x0107001356000002bf (9 bytes) 18:48:05.315 SERIAL » [ACK] (0x06) 18:48:05.316 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:05.316 DRIVER ACK received from node for current transaction. RTT = 4737.49 ms 18:48:10.577 DRIVER The awake timeout for node 5 has elapsed. Assuming it is asleep. 18:48:10.577 CNTRLR [Node 005] The node is now asleep. 18:48:10.579 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:48:10.579 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:48:45.032 SERIAL « 0x01 (1 bytes) 18:48:45.033 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:45.035 CNTRLR [Node 004] [~] [Battery] level: 40 => 40 [Endpoint 0] 18:48:45.034 SERIAL « 0x0900040004038003285e (10 bytes) 18:48:45.034 SERIAL Buffer := 0x010900040004038003285e (11 bytes) 18:48:45.038 SERIAL » [ACK] (0x06) 18:48:45.039 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:45.037 CNTRLR [Node 004] [~] [Battery] isLow: false => false [Endpoint 0] 18:48:45.054 SERIAL « 0x01 (1 bytes) 18:48:45.054 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:45.057 CNTRLR [Node 004] [~] [Thermostat Setpoint] setpoint[1]: 5 => 5 [Endpoint 0] 18:48:45.055 SERIAL « 0x0c00040004064303014201f403 (13 bytes) 18:48:45.056 SERIAL Buffer := 0x010c00040004064303014201f403 (14 bytes) 18:48:45.058 SERIAL » [ACK] (0x06) 18:48:45.059 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:45.073 SERIAL « 0x01 (1 bytes) 18:48:45.073 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:45.074 SERIAL « 0x0a00040004044608007fc0 (11 bytes) 18:48:45.076 CNTRLR [Node 004] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:48:45.075 SERIAL Buffer := 0x010a00040004044608007fc0 (12 bytes) 18:48:45.079 SERIAL » [ACK] (0x06) 18:48:45.080 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:45.078 CNTRLR [Node 004] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:48:45.093 SERIAL « 0x01 (1 bytes) 18:48:45.093 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:45.096 CNTRLR « [Node 004] received wakeup notification 18:48:45.102 DRIVER » [Node 004] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 139 └─[ThermostatSetpointCCGet] payload: 0x07 18:48:45.094 SERIAL « 0x080004000402840776 (9 bytes) 18:48:45.095 SERIAL Buffer := 0x01080004000402840776 (10 bytes) 18:48:45.095 SERIAL » [ACK] (0x06) 18:48:45.099 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:45.105 SERIAL » 0x010a00130403430207258b09 (12 bytes) 18:48:45.097 CNTRLR [Node 004] The node is now awake. 18:48:45.113 SERIAL « [ACK] (0x06) 18:48:45.114 DRIVER Unexpected ACK received 18:48:45.114 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:45.119 SERIAL « 0x01 (1 bytes) 18:48:45.119 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:45.124 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:48:45.122 SERIAL « 0x04011301e8 (5 bytes) 18:48:45.122 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:48:45.123 SERIAL » [ACK] (0x06) 18:48:45.126 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:45.136 SERIAL « 0x01 (1 bytes) 18:48:45.137 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:45.140 DRIVER « [REQ] [SendData] [confirmation] callbackId: 139 transmitStatus: OK 18:48:45.138 SERIAL « 0x0700138b00000262 (8 bytes) 18:48:45.138 SERIAL Buffer := 0x010700138b00000262 (9 bytes) 18:48:45.139 SERIAL » [ACK] (0x06) 18:48:45.141 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:45.140 DRIVER ACK received from node for current transaction. RTT = 39.90 ms 18:48:46.181 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:48:46.681 DRIVER » [Node 004] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 139 └─[ThermostatSetpointCCGet] payload: 0x07 18:48:46.682 SERIAL » 0x010a00130403430207258b09 (12 bytes) 18:48:46.685 SERIAL « [ACK] (0x06) 18:48:46.686 DRIVER ACK received from controller for current transaction 18:48:46.687 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:46.692 SERIAL « 0x01 (1 bytes) 18:48:46.692 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:46.694 SERIAL « 0x04011301e8 (5 bytes) 18:48:46.695 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:48:46.694 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:48:46.694 SERIAL » [ACK] (0x06) 18:48:46.696 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:46.708 SERIAL « 0x01 (1 bytes) 18:48:46.709 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:46.711 SERIAL « 0x0700138b00000363 (8 bytes) 18:48:46.712 DRIVER « [REQ] [SendData] [confirmation] callbackId: 139 transmitStatus: OK 18:48:46.711 SERIAL Buffer := 0x010700138b00000363 (9 bytes) 18:48:46.712 SERIAL » [ACK] (0x06) 18:48:46.713 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:46.712 DRIVER ACK received from node for current transaction. RTT = 1612.05 ms 18:48:49.326 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:48:49.827 DRIVER » [Node 004] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 139 └─[ThermostatSetpointCCGet] payload: 0x07 18:48:49.827 SERIAL » 0x010a00130403430207258b09 (12 bytes) 18:48:49.831 SERIAL « [ACK] (0x06) 18:48:49.832 DRIVER ACK received from controller for current transaction 18:48:49.832 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:49.838 SERIAL « 0x01 (1 bytes) 18:48:49.838 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:49.840 SERIAL « 0x04011301e8 (5 bytes) 18:48:49.841 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:48:49.841 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:48:49.841 SERIAL » [ACK] (0x06) 18:48:49.842 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:49.855 SERIAL « 0x01 (1 bytes) 18:48:49.856 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:49.857 SERIAL « 0x0700138b00000262 (8 bytes) 18:48:49.858 DRIVER « [REQ] [SendData] [confirmation] callbackId: 139 transmitStatus: OK 18:48:49.858 SERIAL Buffer := 0x010700138b00000262 (9 bytes) 18:48:49.858 SERIAL » [ACK] (0x06) 18:48:49.859 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:49.859 DRIVER ACK received from node for current transaction. RTT = 4758.31 ms 18:48:52.717 SERIAL « 0x01 (1 bytes) 18:48:52.718 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:52.719 SERIAL « 0x09000400060380035024 (10 bytes) 18:48:52.721 CNTRLR [Node 006] [~] [Battery] level: 80 => 80 [Endpoint 0] 18:48:52.720 SERIAL Buffer := 0x0109000400060380035024 (11 bytes) 18:48:52.724 SERIAL » [ACK] (0x06) 18:48:52.725 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:52.723 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 0] 18:48:52.739 SERIAL « 0x01 (1 bytes) 18:48:52.740 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:52.743 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpoint[1]: 4 => 4 [Endpoint 0] 18:48:52.745 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[ThermostatSetpointCCReport] payload: 0x01420190 18:48:52.742 SERIAL « 0x0c000400060643030142019065 (13 bytes) 18:48:52.742 SERIAL Buffer := 0x010c000400060643030142019065 (14 bytes) 18:48:52.745 SERIAL » [ACK] (0x06) 18:48:52.748 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:52.746 CNTRLR [Node 006] The node is now awake. 18:48:52.748 CNTRLR « [Node 004] received current value of setpoint Furnace: 4 °C 18:48:52.748 CNTRLR » [Node 004] querying current value of setpoint Dry Air... 18:48:52.747 DRIVER ACK already received, resolving transaction 18:48:52.747 DRIVER resuming send queue 18:48:52.750 DRIVER » [Node 006] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:48:52.751 DRIVER workOffSendQueue > skipping because a transaction is pending 18:48:52.751 DRIVER workOffSendQueue > skipping because a transaction is pending 18:48:52.751 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:48:52.760 SERIAL « 0x01 (1 bytes) 18:48:52.760 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:52.762 SERIAL « 0x0a00040006044608007fc2 (11 bytes) 18:48:52.763 CNTRLR [Node 006] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:48:52.762 SERIAL Buffer := 0x010a00040006044608007fc2 (12 bytes) 18:48:52.766 SERIAL » [ACK] (0x06) 18:48:52.767 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:52.765 CNTRLR [Node 006] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:48:52.769 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 18:48:52.769 SERIAL « [CAN] (0x18) 18:48:52.769 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:52.779 SERIAL « 0x01 (1 bytes) 18:48:52.780 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:52.786 SERIAL « 0x080004000602840774 (9 bytes) 18:48:52.788 CNTRLR « [Node 006] received wakeup notification 18:48:52.786 SERIAL Buffer := 0x01080004000602840774 (10 bytes) 18:48:52.788 SERIAL » [ACK] (0x06) 18:48:52.789 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:52.870 DRIVER » [Node 006] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:48:52.871 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:48:52.877 SERIAL « [ACK] (0x06) 18:48:52.877 DRIVER ACK received from controller for current transaction 18:48:52.877 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:52.883 SERIAL « 0x01 (1 bytes) 18:48:52.883 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:52.884 SERIAL « 0x04011301e8 (5 bytes) 18:48:52.885 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:48:52.885 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:48:52.885 SERIAL » [ACK] (0x06) 18:48:52.886 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:52.901 SERIAL « 0x01 (1 bytes) 18:48:52.901 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:52.902 SERIAL « 0x0700136e00000287 (8 bytes) 18:48:52.903 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:48:52.902 SERIAL Buffer := 0x010700136e00000287 (9 bytes) 18:48:52.903 SERIAL » [ACK] (0x06) 18:48:52.904 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:52.904 DRIVER ACK received from node for current transaction. RTT = 153.77 ms 18:48:54.058 CNTRLR [Node 006] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:48:54.558 DRIVER » [Node 006] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:48:54.559 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:48:54.563 SERIAL « [ACK] (0x06) 18:48:54.564 DRIVER ACK received from controller for current transaction 18:48:54.564 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:54.570 SERIAL « 0x01 (1 bytes) 18:48:54.570 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:54.572 SERIAL « 0x04011301e8 (5 bytes) 18:48:54.573 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:48:54.572 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:48:54.573 SERIAL » [ACK] (0x06) 18:48:54.576 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:54.587 SERIAL « 0x01 (1 bytes) 18:48:54.588 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:54.589 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:48:54.588 SERIAL « 0x0700136e00000386 (8 bytes) 18:48:54.588 SERIAL Buffer := 0x010700136e00000386 (9 bytes) 18:48:54.589 SERIAL » [ACK] (0x06) 18:48:54.590 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:54.590 DRIVER ACK received from node for current transaction. RTT = 1839.61 ms 18:48:57.429 CNTRLR [Node 006] The node did not respond to the current transaction after 3 attempt s. It is probably asleep, moving its messages to the wakeup queue. 18:48:57.429 CNTRLR [Node 006] The node is now asleep. 18:48:57.431 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 140 └─[ThermostatSetpointCCGet] payload: 0x08 18:48:57.431 SERIAL » 0x010a00130403430208258c01 (12 bytes) 18:48:57.435 SERIAL « [ACK] (0x06) 18:48:57.436 DRIVER ACK received from controller for current transaction 18:48:57.436 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:57.441 SERIAL « 0x01 (1 bytes) 18:48:57.442 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:57.444 SERIAL « 0x04011301e8 (5 bytes) 18:48:57.445 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:48:57.444 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:48:57.445 SERIAL » [ACK] (0x06) 18:48:57.446 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:57.458 SERIAL « 0x01 (1 bytes) 18:48:57.459 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:57.460 SERIAL « 0x0700138c00000364 (8 bytes) 18:48:57.461 DRIVER « [REQ] [SendData] [confirmation] callbackId: 140 transmitStatus: OK 18:48:57.461 SERIAL Buffer := 0x010700138c00000364 (9 bytes) 18:48:57.461 SERIAL » [ACK] (0x06) 18:48:57.462 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:57.462 DRIVER ACK received from node for current transaction. RTT = 31.35 ms 18:48:58.494 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:48:58.995 DRIVER » [Node 004] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 140 └─[ThermostatSetpointCCGet] payload: 0x08 18:48:58.996 SERIAL » 0x010a00130403430208258c01 (12 bytes) 18:48:58.999 SERIAL « [ACK] (0x06) 18:48:59.000 DRIVER ACK received from controller for current transaction 18:48:59.000 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:59.005 SERIAL « 0x01 (1 bytes) 18:48:59.006 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:59.008 SERIAL « 0x04011301e8 (5 bytes) 18:48:59.009 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:48:59.009 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:48:59.009 SERIAL » [ACK] (0x06) 18:48:59.010 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:59.022 SERIAL « 0x01 (1 bytes) 18:48:59.023 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:48:59.024 SERIAL « 0x0700138c00000265 (8 bytes) 18:48:59.025 DRIVER « [REQ] [SendData] [confirmation] callbackId: 140 transmitStatus: OK 18:48:59.025 SERIAL Buffer := 0x010700138c00000265 (9 bytes) 18:48:59.025 SERIAL » [ACK] (0x06) 18:48:59.026 SERIAL The receive buffer is empty, waiting for the next chunk... 18:48:59.026 DRIVER ACK received from node for current transaction. RTT = 1595.25 ms 18:49:01.622 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:49:02.123 DRIVER » [Node 004] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 140 └─[ThermostatSetpointCCGet] payload: 0x08 18:49:02.123 SERIAL » 0x010a00130403430208258c01 (12 bytes) 18:49:02.127 SERIAL « [ACK] (0x06) 18:49:02.128 DRIVER ACK received from controller for current transaction 18:49:02.128 SERIAL The receive buffer is empty, waiting for the next chunk... 18:49:02.134 SERIAL « 0x01 (1 bytes) 18:49:02.134 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:49:02.137 SERIAL « 0x04011301e8 (5 bytes) 18:49:02.138 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:49:02.137 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:49:02.137 SERIAL » [ACK] (0x06) 18:49:02.140 SERIAL The receive buffer is empty, waiting for the next chunk... 18:49:02.151 SERIAL « 0x01 (1 bytes) 18:49:02.152 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:49:02.154 SERIAL « 0x0700138c00000265 (8 bytes) 18:49:02.155 DRIVER « [REQ] [SendData] [confirmation] callbackId: 140 transmitStatus: OK 18:49:02.154 SERIAL Buffer := 0x010700138c00000265 (9 bytes) 18:49:02.155 SERIAL » [ACK] (0x06) 18:49:02.157 SERIAL The receive buffer is empty, waiting for the next chunk... 18:49:02.156 DRIVER ACK received from node for current transaction. RTT = 4725.53 ms 18:49:02.747 DRIVER The awake timeout for node 4 has elapsed. Assuming it is asleep. 18:49:02.748 CNTRLR [Node 004] The node is now asleep. 18:49:02.749 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:49:02.751 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:49:19.025 SERIAL « 0x01 (1 bytes) 18:49:19.025 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:49:19.027 CNTRLR [Node 007] [~] [Multilevel Switch] currentValue: 99 => 0 [Endpoint 0] 18:49:19.026 SERIAL « 0x090004000703260300d3 (10 bytes) 18:49:19.026 SERIAL Buffer := 0x01090004000703260300d3 (11 bytes) 18:49:19.028 SERIAL » [ACK] (0x06) 18:49:19.029 SERIAL The receive buffer is empty, waiting for the next chunk... 18:49:20.036 SERIAL « 0x01 (1 bytes) 18:49:20.037 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:49:20.038 SERIAL « 0x10000400070a32022134000000000000c3 (17 bytes) 18:49:20.040 CNTRLR [Node 007] [Meter] value[66049]: metadata updated [Endpoint 0] 18:49:20.039 SERIAL Buffer := 0x0110000400070a32022134000000000000c3 (18 bytes) 18:49:20.048 SERIAL » [ACK] (0x06) 18:49:20.049 SERIAL The receive buffer is empty, waiting for the next chunk... 18:49:20.044 CNTRLR [Node 007] [~] [Meter] value[66049]: 95 => 0 [Endpoint 0] 18:49:20.045 CNTRLR [Node 007] [Meter] deltaTime[66049]: metadata updated [Endpoint 0] 18:49:20.047 CNTRLR [Node 007] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 18:49:21.035 SERIAL « 0x01 (1 bytes) 18:49:21.035 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:49:21.037 CNTRLR [Node 007] [Meter] value[66049]: metadata updated [Endpoint 0] 18:49:21.036 SERIAL « 0x10000400070a32022134000000000000c3 (17 bytes) 18:49:21.036 SERIAL Buffer := 0x0110000400070a32022134000000000000c3 (18 bytes) 18:49:21.044 SERIAL » [ACK] (0x06) 18:49:21.044 SERIAL The receive buffer is empty, waiting for the next chunk... 18:49:21.039 CNTRLR [Node 007] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 18:49:21.041 CNTRLR [Node 007] [Meter] deltaTime[66049]: metadata updated [Endpoint 0] 18:49:21.043 CNTRLR [Node 007] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 18:49:48.208 SERIAL « 0x01 (1 bytes) 18:49:48.209 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:49:48.211 SERIAL « 0x09000400030380033342 (10 bytes) 18:49:48.213 CNTRLR [Node 003] [~] [Battery] level: 51 => 51 [Endpoint 0] 18:49:48.211 SERIAL Buffer := 0x0109000400030380033342 (11 bytes) 18:49:48.216 SERIAL » [ACK] (0x06) 18:49:48.217 SERIAL The receive buffer is empty, waiting for the next chunk... 18:49:48.215 CNTRLR [Node 003] [~] [Battery] isLow: false => false [Endpoint 0] 18:49:48.234 SERIAL « 0x01 (1 bytes) 18:49:48.234 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:49:48.237 CNTRLR [Node 003] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:49:48.236 SERIAL « 0x0c0004000306430301420708fe (13 bytes) 18:49:48.236 SERIAL Buffer := 0x010c0004000306430301420708fe (14 bytes) 18:49:48.239 SERIAL » [ACK] (0x06) 18:49:48.240 SERIAL The receive buffer is empty, waiting for the next chunk... 18:49:48.250 SERIAL « 0x01 (1 bytes) 18:49:48.251 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:49:48.252 SERIAL « 0x0a00040003044608007fc7 (11 bytes) 18:49:48.254 CNTRLR [Node 003] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:49:48.253 SERIAL Buffer := 0x010a00040003044608007fc7 (12 bytes) 18:49:48.257 SERIAL » [ACK] (0x06) 18:49:48.258 SERIAL The receive buffer is empty, waiting for the next chunk... 18:49:48.256 CNTRLR [Node 003] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:49:48.271 SERIAL « 0x01 (1 bytes) 18:49:48.271 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:49:48.276 CNTRLR « [Node 003] received wakeup notification 18:49:48.274 SERIAL « 0x080004000302840771 (9 bytes) 18:49:48.274 SERIAL Buffer := 0x01080004000302840771 (10 bytes) 18:49:48.275 SERIAL » [ACK] (0x06) 18:49:48.278 SERIAL The receive buffer is empty, waiting for the next chunk... 18:49:48.279 DRIVER » [Node 003] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 122 └─[ThermostatSetpointCCGet] payload: 0x02 18:49:48.276 CNTRLR [Node 003] The node is now awake. 18:49:48.280 SERIAL » 0x010a00130303430202257afa (12 bytes) 18:49:48.285 SERIAL « [ACK] (0x06) 18:49:48.285 DRIVER Unexpected ACK received 18:49:48.286 SERIAL The receive buffer is empty, waiting for the next chunk... 18:49:48.291 SERIAL « 0x01 (1 bytes) 18:49:48.292 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:49:48.294 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:49:48.293 SERIAL « 0x04011301e8 (5 bytes) 18:49:48.293 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:49:48.294 SERIAL » [ACK] (0x06) 18:49:48.295 SERIAL The receive buffer is empty, waiting for the next chunk... 18:49:48.307 SERIAL « 0x01 (1 bytes) 18:49:48.308 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:49:48.310 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 18:49:48.309 SERIAL « 0x0700137a00000392 (8 bytes) 18:49:48.309 SERIAL Buffer := 0x010700137a00000392 (9 bytes) 18:49:48.309 SERIAL » [ACK] (0x06) 18:49:48.311 SERIAL The receive buffer is empty, waiting for the next chunk... 18:49:48.310 DRIVER ACK received from node for current transaction. RTT = 31.10 ms 18:49:49.343 CNTRLR [Node 003] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:49:49.844 DRIVER » [Node 003] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 122 └─[ThermostatSetpointCCGet] payload: 0x02 18:49:49.844 SERIAL » 0x010a00130303430202257afa (12 bytes) 18:49:49.848 SERIAL « [ACK] (0x06) 18:49:49.849 DRIVER ACK received from controller for current transaction 18:49:49.849 SERIAL The receive buffer is empty, waiting for the next chunk... 18:49:49.855 SERIAL « 0x01 (1 bytes) 18:49:49.856 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:49:49.857 SERIAL « 0x04011301e8 (5 bytes) 18:49:49.858 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:49:49.857 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:49:49.858 SERIAL » [ACK] (0x06) 18:49:49.858 SERIAL The receive buffer is empty, waiting for the next chunk... 18:49:49.872 SERIAL « 0x01 (1 bytes) 18:49:49.872 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:49:49.874 SERIAL « 0x0700137a00000293 (8 bytes) 18:49:49.875 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 18:49:49.876 DRIVER ACK received from node for current transaction. RTT = 1596.67 ms 18:49:49.874 SERIAL Buffer := 0x010700137a00000293 (9 bytes) 18:49:49.875 SERIAL » [ACK] (0x06) 18:49:49.876 SERIAL The receive buffer is empty, waiting for the next chunk... 18:49:52.472 CNTRLR [Node 003] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:49:52.972 DRIVER » [Node 003] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 122 └─[ThermostatSetpointCCGet] payload: 0x02 18:49:52.973 SERIAL » 0x010a00130303430202257afa (12 bytes) 18:49:52.979 SERIAL « [ACK] (0x06) 18:49:52.979 DRIVER ACK received from controller for current transaction 18:49:52.980 SERIAL The receive buffer is empty, waiting for the next chunk... 18:49:52.983 SERIAL « 0x01 (1 bytes) 18:49:52.984 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:49:52.988 SERIAL « 0x04011301e8 (5 bytes) 18:49:52.989 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:49:52.988 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:49:52.989 SERIAL » [ACK] (0x06) 18:49:52.989 SERIAL The receive buffer is empty, waiting for the next chunk... 18:49:53.000 SERIAL « 0x01 (1 bytes) 18:49:53.001 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:49:53.002 SERIAL « 0x0700137a00000293 (8 bytes) 18:49:53.003 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 18:49:53.002 SERIAL Buffer := 0x010700137a00000293 (9 bytes) 18:49:53.003 SERIAL » [ACK] (0x06) 18:49:53.004 SERIAL The receive buffer is empty, waiting for the next chunk... 18:49:53.004 DRIVER ACK received from node for current transaction. RTT = 4724.79 ms 18:49:58.277 DRIVER The awake timeout for node 3 has elapsed. Assuming it is asleep. 18:49:58.278 CNTRLR [Node 003] The node is now asleep. 18:49:58.279 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:49:58.280 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:50:31.514 SERIAL « 0x01 (1 bytes) 18:50:31.514 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:50:31.515 SERIAL « 0x09000400080380034832 (10 bytes) 18:50:31.517 CNTRLR [Node 008] [~] [Battery] level: 72 => 72 [Endpoint 0] 18:50:31.516 SERIAL Buffer := 0x0109000400080380034832 (11 bytes) 18:50:31.520 SERIAL » [ACK] (0x06) 18:50:31.520 SERIAL The receive buffer is empty, waiting for the next chunk... 18:50:31.519 CNTRLR [Node 008] [~] [Battery] isLow: false => false [Endpoint 0] 18:50:31.536 SERIAL « 0x01 (1 bytes) 18:50:31.537 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:50:31.539 CNTRLR [Node 008] [~] [Thermostat Setpoint] setpoint[1]: 4.5 => 4.5 [Endpoint 0] 18:50:31.538 SERIAL « 0x0c00040008064303014201c239 (13 bytes) 18:50:31.538 SERIAL Buffer := 0x010c00040008064303014201c239 (14 bytes) 18:50:31.540 SERIAL » [ACK] (0x06) 18:50:31.541 SERIAL The receive buffer is empty, waiting for the next chunk... 18:50:31.555 SERIAL « 0x01 (1 bytes) 18:50:31.556 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:50:31.557 SERIAL « 0x0a00040008044608007fcc (11 bytes) 18:50:31.559 CNTRLR [Node 008] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:50:31.558 SERIAL Buffer := 0x010a00040008044608007fcc (12 bytes) 18:50:31.562 SERIAL » [ACK] (0x06) 18:50:31.562 SERIAL The receive buffer is empty, waiting for the next chunk... 18:50:31.561 CNTRLR [Node 008] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:50:31.578 SERIAL « 0x01 (1 bytes) 18:50:31.579 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:50:31.588 CNTRLR [Node 008] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 18:50:31.581 SERIAL « 0x0c000400080631050142079d14 (13 bytes) 18:50:31.586 SERIAL Buffer := 0x010c000400080631050142079d14 (14 bytes) 18:50:31.591 SERIAL » [ACK] (0x06) 18:50:31.591 SERIAL The receive buffer is empty, waiting for the next chunk... 18:50:31.589 CNTRLR [Node 008] [~] [Multilevel Sensor] Air temperature: 19.51 => 19.4 [Endpoint 0] 9 18:50:31.598 SERIAL « 0x01 (1 bytes) 18:50:31.598 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:50:31.601 CNTRLR « [Node 008] received wakeup notification 18:50:31.604 DRIVER » [Node 008] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:50:31.599 SERIAL « 0x08000400080284077a (9 bytes) 18:50:31.600 SERIAL Buffer := 0x0108000400080284077a (10 bytes) 18:50:31.601 SERIAL » [ACK] (0x06) 18:50:31.603 SERIAL The receive buffer is empty, waiting for the next chunk... 18:50:31.605 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:50:31.602 CNTRLR [Node 008] The node is now awake. 18:50:31.609 SERIAL « [ACK] (0x06) 18:50:31.610 DRIVER Unexpected ACK received 18:50:31.610 SERIAL The receive buffer is empty, waiting for the next chunk... 18:50:31.618 SERIAL « 0x0104011301e8 (6 bytes) 18:50:31.619 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:50:31.619 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:50:31.619 SERIAL » [ACK] (0x06) 18:50:31.620 SERIAL The receive buffer is empty, waiting for the next chunk... 18:50:31.632 SERIAL « 0x01 (1 bytes) 18:50:31.632 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:50:31.634 SERIAL « 0x0700138a00000263 (8 bytes) 18:50:31.635 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:50:31.634 SERIAL Buffer := 0x010700138a00000263 (9 bytes) 18:50:31.635 SERIAL » [ACK] (0x06) 18:50:31.636 SERIAL The receive buffer is empty, waiting for the next chunk... 18:50:31.636 DRIVER ACK received from node for current transaction. RTT = 31.57 ms 18:50:32.667 CNTRLR [Node 008] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:50:33.168 DRIVER » [Node 008] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:50:33.169 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:50:33.172 SERIAL « [ACK] (0x06) 18:50:33.173 DRIVER ACK received from controller for current transaction 18:50:33.173 SERIAL The receive buffer is empty, waiting for the next chunk... 18:50:33.179 SERIAL « 0x01 (1 bytes) 18:50:33.180 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:50:33.181 SERIAL « 0x04011301e8 (5 bytes) 18:50:33.183 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:50:33.182 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:50:33.182 SERIAL » [ACK] (0x06) 18:50:33.183 SERIAL The receive buffer is empty, waiting for the next chunk... 18:50:33.196 SERIAL « 0x01 (1 bytes) 18:50:33.196 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:50:33.198 SERIAL « 0x0700138a00000263 (8 bytes) 18:50:33.199 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:50:33.198 SERIAL Buffer := 0x010700138a00000263 (9 bytes) 18:50:33.199 SERIAL » [ACK] (0x06) 18:50:33.200 SERIAL The receive buffer is empty, waiting for the next chunk... 18:50:33.200 DRIVER ACK received from node for current transaction. RTT = 1595.51 ms 18:50:35.795 CNTRLR [Node 008] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:50:36.297 DRIVER » [Node 008] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:50:36.297 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:50:36.301 SERIAL « [ACK] (0x06) 18:50:36.301 DRIVER ACK received from controller for current transaction 18:50:36.302 SERIAL The receive buffer is empty, waiting for the next chunk... 18:50:36.307 SERIAL « 0x01 (1 bytes) 18:50:36.308 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:50:36.309 SERIAL « 0x04011301e8 (5 bytes) 18:50:36.311 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:50:36.310 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:50:36.310 SERIAL » [ACK] (0x06) 18:50:36.311 SERIAL The receive buffer is empty, waiting for the next chunk... 18:50:36.324 SERIAL « 0x01 (1 bytes) 18:50:36.325 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:50:36.326 SERIAL « 0x0700138a00000263 (8 bytes) 18:50:36.328 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:50:36.328 DRIVER ACK received from node for current transaction. RTT = 4723.96 ms 18:50:36.327 SERIAL Buffer := 0x010700138a00000263 (9 bytes) 18:50:36.327 SERIAL » [ACK] (0x06) 18:50:36.329 SERIAL The receive buffer is empty, waiting for the next chunk... 18:50:41.602 DRIVER The awake timeout for node 8 has elapsed. Assuming it is asleep. 18:50:41.602 CNTRLR [Node 008] The node is now asleep. 18:50:41.604 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:50:41.604 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:51:21.915 SERIAL « 0x01 (1 bytes) 18:51:21.916 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:51:21.919 CNTRLR [Node 002] [~] [Battery] level: 80 => 80 [Endpoint 0] 18:51:21.917 SERIAL « 0x09000400020380035020 (10 bytes) 18:51:21.918 SERIAL Buffer := 0x0109000400020380035020 (11 bytes) 18:51:21.922 SERIAL » [ACK] (0x06) 18:51:21.923 SERIAL The receive buffer is empty, waiting for the next chunk... 18:51:21.921 CNTRLR [Node 002] [~] [Battery] isLow: false => false [Endpoint 0] 18:51:21.937 SERIAL « 0x01 (1 bytes) 18:51:21.938 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:51:21.939 SERIAL « 0x0c0004000206430301420708ff (13 bytes) 18:51:21.941 CNTRLR [Node 002] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:51:21.940 SERIAL Buffer := 0x010c0004000206430301420708ff (14 bytes) 18:51:21.942 SERIAL » [ACK] (0x06) 18:51:21.944 SERIAL The receive buffer is empty, waiting for the next chunk... 18:51:21.957 SERIAL « 0x01 (1 bytes) 18:51:21.957 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:51:21.960 CNTRLR [Node 002] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:51:21.963 CNTRLR [Node 002] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:51:21.958 SERIAL « 0x0a00040002044608007fc6 (11 bytes) 18:51:21.959 SERIAL Buffer := 0x010a00040002044608007fc6 (12 bytes) 18:51:21.964 SERIAL » [ACK] (0x06) 18:51:21.965 SERIAL The receive buffer is empty, waiting for the next chunk... 18:51:21.979 SERIAL « 0x01 (1 bytes) 18:51:21.979 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:51:21.984 CNTRLR « [Node 002] received wakeup notification 18:51:21.981 SERIAL « 0x080004000202840770 (9 bytes) 18:51:21.983 SERIAL Buffer := 0x01080004000202840770 (10 bytes) 18:51:21.984 SERIAL » [ACK] (0x06) 18:51:21.987 SERIAL The receive buffer is empty, waiting for the next chunk... 18:51:21.988 DRIVER » [Node 002] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:51:21.985 CNTRLR [Node 002] The node is now awake. 18:51:21.989 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:51:21.993 SERIAL « [ACK] (0x06) 18:51:21.993 DRIVER Unexpected ACK received 18:51:21.994 SERIAL The receive buffer is empty, waiting for the next chunk... 18:51:22.002 SERIAL « 0x01 (1 bytes) 18:51:22.002 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:51:22.005 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:51:22.004 SERIAL « 0x04011301e8 (5 bytes) 18:51:22.004 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:51:22.005 SERIAL » [ACK] (0x06) 18:51:22.006 SERIAL The receive buffer is empty, waiting for the next chunk... 18:51:22.017 SERIAL « 0x01 (1 bytes) 18:51:22.017 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:51:22.019 SERIAL « 0x0700134a000002a3 (8 bytes) 18:51:22.020 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:51:22.021 DRIVER ACK received from node for current transaction. RTT = 32.51 ms 18:51:22.019 SERIAL Buffer := 0x010700134a000002a3 (9 bytes) 18:51:22.020 SERIAL » [ACK] (0x06) 18:51:22.021 SERIAL The receive buffer is empty, waiting for the next chunk... 18:51:23.054 CNTRLR [Node 002] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:51:23.554 DRIVER » [Node 002] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:51:23.555 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:51:23.558 SERIAL « [ACK] (0x06) 18:51:23.559 DRIVER ACK received from controller for current transaction 18:51:23.559 SERIAL The receive buffer is empty, waiting for the next chunk... 18:51:23.565 SERIAL « 0x01 (1 bytes) 18:51:23.566 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:51:23.567 SERIAL « 0x04011301e8 (5 bytes) 18:51:23.569 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:51:23.568 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:51:23.568 SERIAL » [ACK] (0x06) 18:51:23.571 SERIAL The receive buffer is empty, waiting for the next chunk... 18:51:23.583 SERIAL « 0x01 (1 bytes) 18:51:23.583 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:51:23.586 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:51:23.584 SERIAL « 0x0700134a000002a3 (8 bytes) 18:51:23.585 SERIAL Buffer := 0x010700134a000002a3 (9 bytes) 18:51:23.585 SERIAL » [ACK] (0x06) 18:51:23.587 SERIAL The receive buffer is empty, waiting for the next chunk... 18:51:23.586 DRIVER ACK received from node for current transaction. RTT = 1598.33 ms 18:51:26.186 CNTRLR [Node 002] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:51:26.686 DRIVER » [Node 002] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:51:26.687 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:51:26.690 SERIAL « [ACK] (0x06) 18:51:26.691 DRIVER ACK received from controller for current transaction 18:51:26.691 SERIAL The receive buffer is empty, waiting for the next chunk... 18:51:26.697 SERIAL « 0x01 (1 bytes) 18:51:26.698 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:51:26.700 SERIAL « 0x04011301e8 (5 bytes) 18:51:26.702 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:51:26.701 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:51:26.701 SERIAL » [ACK] (0x06) 18:51:26.705 SERIAL The receive buffer is empty, waiting for the next chunk... 18:51:26.714 SERIAL « 0x01 (1 bytes) 18:51:26.715 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:51:26.716 SERIAL « 0x0700134a000002a3 (8 bytes) 18:51:26.717 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:51:26.717 SERIAL Buffer := 0x010700134a000002a3 (9 bytes) 18:51:26.717 SERIAL » [ACK] (0x06) 18:51:26.718 SERIAL The receive buffer is empty, waiting for the next chunk... 18:51:26.718 DRIVER ACK received from node for current transaction. RTT = 4729.77 ms 18:51:31.986 DRIVER The awake timeout for node 2 has elapsed. Assuming it is asleep. 18:51:31.987 CNTRLR [Node 002] The node is now asleep. 18:51:31.988 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:51:31.989 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:52:53.767 SERIAL « 0x01 (1 bytes) 18:52:53.768 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:52:53.769 SERIAL « 0x09000400050380033a4d (10 bytes) 18:52:53.770 CNTRLR [Node 005] [~] [Battery] level: 58 => 58 [Endpoint 0] 18:52:53.772 CNTRLR [Node 005] [~] [Battery] isLow: false => false [Endpoint 0] 18:52:53.769 SERIAL Buffer := 0x0109000400050380033a4d (11 bytes) 18:52:53.773 SERIAL » [ACK] (0x06) 18:52:53.774 SERIAL The receive buffer is empty, waiting for the next chunk... 18:52:53.788 SERIAL « 0x01 (1 bytes) 18:52:53.789 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:52:53.792 CNTRLR [Node 005] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:52:53.790 SERIAL « 0x0c0004000506430301420708f8 (13 bytes) 18:52:53.791 SERIAL Buffer := 0x010c0004000506430301420708f8 (14 bytes) 18:52:53.793 SERIAL » [ACK] (0x06) 18:52:53.794 SERIAL The receive buffer is empty, waiting for the next chunk... 18:52:53.808 SERIAL « 0x01 (1 bytes) 18:52:53.809 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:52:53.810 SERIAL « 0x0a00040005044608007fc1 (11 bytes) 18:52:53.811 CNTRLR [Node 005] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:52:53.810 SERIAL Buffer := 0x010a00040005044608007fc1 (12 bytes) 18:52:53.814 SERIAL » [ACK] (0x06) 18:52:53.815 SERIAL The receive buffer is empty, waiting for the next chunk... 18:52:53.813 CNTRLR [Node 005] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:52:53.829 SERIAL « 0x01 (1 bytes) 18:52:53.830 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:52:53.834 CNTRLR « [Node 005] received wakeup notification 18:52:53.838 DRIVER » [Node 005] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:52:53.831 SERIAL « 0x080004000502840777 (9 bytes) 18:52:53.831 SERIAL Buffer := 0x01080004000502840777 (10 bytes) 18:52:53.833 SERIAL » [ACK] (0x06) 18:52:53.836 SERIAL The receive buffer is empty, waiting for the next chunk... 18:52:53.839 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:52:53.834 CNTRLR [Node 005] The node is now awake. 18:52:53.844 SERIAL « [ACK] (0x06) 18:52:53.844 DRIVER Unexpected ACK received 18:52:53.845 SERIAL The receive buffer is empty, waiting for the next chunk... 18:52:53.850 SERIAL « 0x01 (1 bytes) 18:52:53.850 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:52:53.853 SERIAL « 0x04011301e8 (5 bytes) 18:52:53.854 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:52:53.853 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:52:53.853 SERIAL » [ACK] (0x06) 18:52:53.854 SERIAL The receive buffer is empty, waiting for the next chunk... 18:52:53.866 SERIAL « 0x01 (1 bytes) 18:52:53.867 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:52:53.870 SERIAL « 0x07001356000002bf (8 bytes) 18:52:53.871 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:52:53.870 SERIAL Buffer := 0x0107001356000002bf (9 bytes) 18:52:53.871 SERIAL » [ACK] (0x06) 18:52:53.872 SERIAL The receive buffer is empty, waiting for the next chunk... 18:52:53.872 DRIVER ACK received from node for current transaction. RTT = 33.85 ms 18:52:54.905 CNTRLR [Node 005] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:52:55.406 DRIVER » [Node 005] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:52:55.407 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:52:55.411 SERIAL « [ACK] (0x06) 18:52:55.412 DRIVER ACK received from controller for current transaction 18:52:55.412 SERIAL The receive buffer is empty, waiting for the next chunk... 18:52:55.417 SERIAL « 0x01 (1 bytes) 18:52:55.418 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:52:55.422 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:52:55.420 SERIAL « 0x04011301e8 (5 bytes) 18:52:55.421 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:52:55.421 SERIAL » [ACK] (0x06) 18:52:55.424 SERIAL The receive buffer is empty, waiting for the next chunk... 18:52:55.434 SERIAL « 0x01 (1 bytes) 18:52:55.434 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:52:55.436 SERIAL « 0x07001356000002bf (8 bytes) 18:52:55.437 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:52:55.437 SERIAL Buffer := 0x0107001356000002bf (9 bytes) 18:52:55.437 SERIAL » [ACK] (0x06) 18:52:55.438 SERIAL The receive buffer is empty, waiting for the next chunk... 18:52:55.438 DRIVER ACK received from node for current transaction. RTT = 1600.08 ms 18:52:58.039 CNTRLR [Node 005] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:52:58.540 DRIVER » [Node 005] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:52:58.540 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:52:58.544 SERIAL « [ACK] (0x06) 18:52:58.545 DRIVER ACK received from controller for current transaction 18:52:58.545 SERIAL The receive buffer is empty, waiting for the next chunk... 18:52:58.551 SERIAL « 0x01 (1 bytes) 18:52:58.551 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:52:58.552 SERIAL « 0x04011301e8 (5 bytes) 18:52:58.553 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:52:58.553 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:52:58.553 SERIAL » [ACK] (0x06) 18:52:58.554 SERIAL The receive buffer is empty, waiting for the next chunk... 18:52:58.568 SERIAL « 0x01 (1 bytes) 18:52:58.568 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:52:58.569 SERIAL « 0x07001356000003be (8 bytes) 18:52:58.570 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:52:58.570 SERIAL Buffer := 0x0107001356000003be (9 bytes) 18:52:58.570 SERIAL » [ACK] (0x06) 18:52:58.572 SERIAL The receive buffer is empty, waiting for the next chunk... 18:52:58.571 DRIVER ACK received from node for current transaction. RTT = 4733.08 ms 18:53:03.835 DRIVER The awake timeout for node 5 has elapsed. Assuming it is asleep. 18:53:03.835 CNTRLR [Node 005] The node is now asleep. 18:53:03.837 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:53:03.837 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:53:43.252 SERIAL « 0x01 (1 bytes) 18:53:43.252 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:53:43.255 CNTRLR [Node 004] [~] [Battery] level: 40 => 40 [Endpoint 0] 18:53:43.253 SERIAL « 0x0900040004038003285e (10 bytes) 18:53:43.254 SERIAL Buffer := 0x010900040004038003285e (11 bytes) 18:53:43.258 SERIAL » [ACK] (0x06) 18:53:43.258 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:43.257 CNTRLR [Node 004] [~] [Battery] isLow: false => false [Endpoint 0] 18:53:43.275 SERIAL « 0x01 (1 bytes) 18:53:43.275 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:53:43.279 CNTRLR [Node 004] [~] [Thermostat Setpoint] setpoint[1]: 5 => 5 [Endpoint 0] 18:53:43.277 SERIAL « 0x0c00040004064303014201f403 (13 bytes) 18:53:43.278 SERIAL Buffer := 0x010c00040004064303014201f403 (14 bytes) 18:53:43.280 SERIAL » [ACK] (0x06) 18:53:43.281 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:43.294 SERIAL « 0x01 (1 bytes) 18:53:43.294 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:53:43.296 SERIAL « 0x0a00040004044608007fc0 (11 bytes) 18:53:43.298 CNTRLR [Node 004] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:53:43.296 SERIAL Buffer := 0x010a00040004044608007fc0 (12 bytes) 18:53:43.301 SERIAL » [ACK] (0x06) 18:53:43.302 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:43.299 CNTRLR [Node 004] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:53:43.316 SERIAL « 0x01080004000402840776 (10 bytes) 18:53:43.319 CNTRLR « [Node 004] received wakeup notification 18:53:43.322 DRIVER » [Node 004] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 140 └─[ThermostatSetpointCCGet] payload: 0x08 18:53:43.316 SERIAL Buffer := 0x01080004000402840776 (10 bytes) 18:53:43.317 SERIAL » [ACK] (0x06) 18:53:43.321 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:43.322 SERIAL » 0x010a00130403430208258c01 (12 bytes) 18:53:43.319 CNTRLR [Node 004] The node is now awake. 18:53:43.328 SERIAL « [ACK] (0x06) 18:53:43.329 DRIVER Unexpected ACK received 18:53:43.330 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:43.333 SERIAL « 0x01 (1 bytes) 18:53:43.333 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:53:43.334 SERIAL « 0x04011301e8 (5 bytes) 18:53:43.336 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:53:43.335 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:53:43.335 SERIAL » [ACK] (0x06) 18:53:43.336 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:43.350 SERIAL « 0x01 (1 bytes) 18:53:43.350 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:53:43.353 SERIAL « 0x0700138c00000265 (8 bytes) 18:53:43.354 DRIVER « [REQ] [SendData] [confirmation] callbackId: 140 transmitStatus: OK 18:53:43.353 SERIAL Buffer := 0x010700138c00000265 (9 bytes) 18:53:43.353 SERIAL » [ACK] (0x06) 18:53:43.355 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:43.354 DRIVER ACK received from node for current transaction. RTT = 32.79 ms 18:53:43.362 SERIAL « 0x01 (1 bytes) 18:53:43.362 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:53:43.365 SERIAL « 0x09000400060380035024 (10 bytes) 18:53:43.366 CNTRLR [Node 006] [~] [Battery] level: 80 => 80 [Endpoint 0] 18:53:43.365 SERIAL Buffer := 0x0109000400060380035024 (11 bytes) 18:53:43.369 SERIAL » [ACK] (0x06) 18:53:43.369 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:43.368 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 0] 18:53:43.385 SERIAL « 0x01 (1 bytes) 18:53:43.385 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:53:43.389 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpoint[1]: 4 => 4 [Endpoint 0] 18:53:43.392 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[ThermostatSetpointCCReport] payload: 0x01420190 18:53:43.386 SERIAL « 0x0c000400060643030142019065 (13 bytes) 18:53:43.387 SERIAL Buffer := 0x010c000400060643030142019065 (14 bytes) 18:53:43.391 SERIAL » [ACK] (0x06) 18:53:43.395 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:43.397 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:53:43.392 CNTRLR [Node 006] The node is now awake. 18:53:43.395 CNTRLR « [Node 004] received current value of setpoint Dry Air: 4 °C 18:53:43.395 CNTRLR » [Node 004] querying current value of setpoint Moist Air... 18:53:43.394 DRIVER ACK already received, resolving transaction 18:53:43.394 DRIVER resuming send queue 18:53:43.397 DRIVER » [Node 006] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:53:43.398 DRIVER workOffSendQueue > skipping because a transaction is pending 18:53:43.398 DRIVER workOffSendQueue > skipping because a transaction is pending 18:53:43.404 SERIAL « 0x01 (1 bytes) 18:53:43.405 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:53:43.408 CNTRLR [Node 006] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:53:43.413 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 18:53:43.406 SERIAL « 0x0a00040006044608007fc218 (12 bytes) 18:53:43.407 SERIAL Buffer := 0x010a00040006044608007fc218 (13 bytes) 18:53:43.412 SERIAL » [ACK] (0x06) 18:53:43.412 SERIAL « [CAN] (0x18) 18:53:43.413 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:43.410 CNTRLR [Node 006] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:53:43.426 SERIAL « 0x01080004000602840774 (10 bytes) 18:53:43.430 CNTRLR « [Node 006] received wakeup notification 18:53:43.427 SERIAL Buffer := 0x01080004000602840774 (10 bytes) 18:53:43.429 SERIAL » [ACK] (0x06) 18:53:43.431 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:43.514 DRIVER » [Node 006] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:53:43.514 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:53:43.518 SERIAL « [ACK] (0x06) 18:53:43.519 DRIVER ACK received from controller for current transaction 18:53:43.519 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:43.524 SERIAL « 0x01 (1 bytes) 18:53:43.525 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:53:43.530 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:53:43.529 SERIAL « 0x04011301e8 (5 bytes) 18:53:43.529 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:53:43.529 SERIAL » [ACK] (0x06) 18:53:43.532 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:43.542 SERIAL « 0x01 (1 bytes) 18:53:43.542 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:53:43.545 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:53:43.544 SERIAL « 0x0700136e00000287 (8 bytes) 18:53:43.544 SERIAL Buffer := 0x010700136e00000287 (9 bytes) 18:53:43.545 SERIAL » [ACK] (0x06) 18:53:43.547 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:43.546 DRIVER ACK received from node for current transaction. RTT = 149.12 ms 18:53:44.696 CNTRLR [Node 006] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:53:45.198 DRIVER » [Node 006] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 110 └─[ThermostatSetpointCCGet] payload: 0x02 18:53:45.198 SERIAL » 0x010a00130603430202256eeb (12 bytes) 18:53:45.202 SERIAL « [ACK] (0x06) 18:53:45.203 DRIVER ACK received from controller for current transaction 18:53:45.203 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:45.209 SERIAL « 0x01 (1 bytes) 18:53:45.210 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:53:45.210 SERIAL « 0x04011301e8 (5 bytes) 18:53:45.212 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:53:45.211 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:53:45.211 SERIAL » [ACK] (0x06) 18:53:45.212 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:45.226 SERIAL « 0x01 (1 bytes) 18:53:45.226 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:53:45.228 SERIAL « 0x0700136e00000287 (8 bytes) 18:53:45.229 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 18:53:45.230 DRIVER ACK received from node for current transaction. RTT = 1832.94 ms 18:53:45.229 SERIAL Buffer := 0x010700136e00000287 (9 bytes) 18:53:45.229 SERIAL » [ACK] (0x06) 18:53:45.230 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:48.063 CNTRLR [Node 006] The node did not respond to the current transaction after 3 attempt s. It is probably asleep, moving its messages to the wakeup queue. 18:53:48.064 CNTRLR [Node 006] The node is now asleep. 18:53:48.066 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 141 └─[ThermostatSetpointCCGet] payload: 0x09 18:53:48.066 SERIAL » 0x010a00130403430209258d01 (12 bytes) 18:53:48.070 SERIAL « [ACK] (0x06) 18:53:48.071 DRIVER ACK received from controller for current transaction 18:53:48.071 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:48.077 SERIAL « 0x01 (1 bytes) 18:53:48.077 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:53:48.078 SERIAL « 0x04011301e8 (5 bytes) 18:53:48.080 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:53:48.079 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:53:48.079 SERIAL » [ACK] (0x06) 18:53:48.080 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:48.095 SERIAL « 0x01 (1 bytes) 18:53:48.095 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:53:48.097 DRIVER « [REQ] [SendData] [confirmation] callbackId: 141 transmitStatus: OK 18:53:48.096 SERIAL « 0x0700138d00000264 (8 bytes) 18:53:48.096 SERIAL Buffer := 0x010700138d00000264 (9 bytes) 18:53:48.097 SERIAL » [ACK] (0x06) 18:53:48.098 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:48.097 DRIVER ACK received from node for current transaction. RTT = 32.03 ms 18:53:49.130 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:53:49.631 DRIVER » [Node 004] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 141 └─[ThermostatSetpointCCGet] payload: 0x09 18:53:49.632 SERIAL » 0x010a00130403430209258d01 (12 bytes) 18:53:49.636 SERIAL « [ACK] (0x06) 18:53:49.637 DRIVER ACK received from controller for current transaction 18:53:49.637 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:49.642 SERIAL « 0x01 (1 bytes) 18:53:49.643 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:53:49.644 SERIAL « 0x04011301e8 (5 bytes) 18:53:49.646 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:53:49.645 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:53:49.645 SERIAL » [ACK] (0x06) 18:53:49.646 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:49.659 SERIAL « 0x01 (1 bytes) 18:53:49.659 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:53:49.661 SERIAL « 0x0700138d00000365 (8 bytes) 18:53:49.669 DRIVER « [REQ] [SendData] [confirmation] callbackId: 141 transmitStatus: OK 18:53:49.662 SERIAL Buffer := 0x010700138d00000365 (9 bytes) 18:53:49.662 SERIAL » [ACK] (0x06) 18:53:49.670 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:49.669 DRIVER ACK received from node for current transaction. RTT = 1604.05 ms 18:53:52.275 CNTRLR [Node 004] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:53:52.776 DRIVER » [Node 004] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 141 └─[ThermostatSetpointCCGet] payload: 0x09 18:53:52.776 SERIAL » 0x010a00130403430209258d01 (12 bytes) 18:53:52.779 SERIAL « [ACK] (0x06) 18:53:52.780 DRIVER ACK received from controller for current transaction 18:53:52.780 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:52.787 SERIAL « 0x0104 (2 bytes) 18:53:52.787 SERIAL [incomplete] Buffer := 0x0104 (2 bytes) 18:53:52.789 SERIAL « 0x011301e8 (4 bytes) 18:53:52.790 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:53:52.790 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:53:52.790 SERIAL » [ACK] (0x06) 18:53:52.791 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:52.804 SERIAL « 0x01 (1 bytes) 18:53:52.804 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:53:52.806 DRIVER « [REQ] [SendData] [confirmation] callbackId: 141 transmitStatus: OK 18:53:52.805 SERIAL « 0x0700138d00000264 (8 bytes) 18:53:52.805 SERIAL Buffer := 0x010700138d00000264 (9 bytes) 18:53:52.806 SERIAL » [ACK] (0x06) 18:53:52.807 SERIAL The receive buffer is empty, waiting for the next chunk... 18:53:52.807 DRIVER ACK received from node for current transaction. RTT = 4741.13 ms 18:53:53.395 DRIVER The awake timeout for node 4 has elapsed. Assuming it is asleep. 18:53:53.396 CNTRLR [Node 004] The node is now asleep. 18:53:53.397 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:53:53.399 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:54:44.131 SERIAL « 0x01 (1 bytes) 18:54:44.132 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:54:44.133 SERIAL « 0x09000400030380033342 (10 bytes) 18:54:44.135 CNTRLR [Node 003] [~] [Battery] level: 51 => 51 [Endpoint 0] 18:54:44.134 SERIAL Buffer := 0x0109000400030380033342 (11 bytes) 18:54:44.138 SERIAL » [ACK] (0x06) 18:54:44.138 SERIAL The receive buffer is empty, waiting for the next chunk... 18:54:44.137 CNTRLR [Node 003] [~] [Battery] isLow: false => false [Endpoint 0] 18:54:44.153 SERIAL « 0x01 (1 bytes) 18:54:44.153 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:54:44.156 SERIAL « 0x0c0004000306430301420708fe (13 bytes) 18:54:44.158 CNTRLR [Node 003] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:54:44.157 SERIAL Buffer := 0x010c0004000306430301420708fe (14 bytes) 18:54:44.159 SERIAL » [ACK] (0x06) 18:54:44.160 SERIAL The receive buffer is empty, waiting for the next chunk... 18:54:44.172 SERIAL « 0x01 (1 bytes) 18:54:44.172 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:54:44.174 SERIAL « 0x0a00040003044608007fc7 (11 bytes) 18:54:44.177 CNTRLR [Node 003] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:54:44.174 SERIAL Buffer := 0x010a00040003044608007fc7 (12 bytes) 18:54:44.180 SERIAL » [ACK] (0x06) 18:54:44.180 SERIAL The receive buffer is empty, waiting for the next chunk... 18:54:44.178 CNTRLR [Node 003] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:54:44.197 SERIAL « 0x01 (1 bytes) 18:54:44.197 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:54:44.201 CNTRLR « [Node 003] received wakeup notification 18:54:44.199 SERIAL « 0x080004000302840771 (9 bytes) 18:54:44.199 SERIAL Buffer := 0x01080004000302840771 (10 bytes) 18:54:44.200 SERIAL » [ACK] (0x06) 18:54:44.202 SERIAL The receive buffer is empty, waiting for the next chunk... 18:54:44.204 DRIVER » [Node 003] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 122 └─[ThermostatSetpointCCGet] payload: 0x02 18:54:44.201 CNTRLR [Node 003] The node is now awake. 18:54:44.205 SERIAL » 0x010a00130303430202257afa (12 bytes) 18:54:44.209 SERIAL « [ACK] (0x06) 18:54:44.210 DRIVER Unexpected ACK received 18:54:44.210 SERIAL The receive buffer is empty, waiting for the next chunk... 18:54:44.215 SERIAL « 0x01 (1 bytes) 18:54:44.216 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:54:44.218 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:54:44.217 SERIAL « 0x04011301e8 (5 bytes) 18:54:44.217 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:54:44.218 SERIAL » [ACK] (0x06) 18:54:44.218 SERIAL The receive buffer is empty, waiting for the next chunk... 18:54:44.232 SERIAL « 0x01 (1 bytes) 18:54:44.233 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:54:44.234 SERIAL « 0x0700137a00000293 (8 bytes) 18:54:44.236 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 18:54:44.235 SERIAL Buffer := 0x010700137a00000293 (9 bytes) 18:54:44.235 SERIAL » [ACK] (0x06) 18:54:44.237 SERIAL The receive buffer is empty, waiting for the next chunk... 18:54:44.237 DRIVER ACK received from node for current transaction. RTT = 33.38 ms 18:54:45.271 CNTRLR [Node 003] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:54:45.773 DRIVER » [Node 003] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 122 └─[ThermostatSetpointCCGet] payload: 0x02 18:54:45.773 SERIAL » 0x010a00130303430202257afa (12 bytes) 18:54:45.777 SERIAL « [ACK] (0x06) 18:54:45.777 DRIVER ACK received from controller for current transaction 18:54:45.778 SERIAL The receive buffer is empty, waiting for the next chunk... 18:54:45.783 SERIAL « 0x01 (1 bytes) 18:54:45.784 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:54:45.786 SERIAL « 0x04011301e8 (5 bytes) 18:54:45.787 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:54:45.786 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:54:45.786 SERIAL » [ACK] (0x06) 18:54:45.787 SERIAL The receive buffer is empty, waiting for the next chunk... 18:54:45.800 SERIAL « 0x010700137a00000293 (9 bytes) 18:54:45.801 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 18:54:45.800 SERIAL Buffer := 0x010700137a00000293 (9 bytes) 18:54:45.801 SERIAL » [ACK] (0x06) 18:54:45.802 SERIAL The receive buffer is empty, waiting for the next chunk... 18:54:45.802 DRIVER ACK received from node for current transaction. RTT = 1598.51 ms 18:54:48.402 CNTRLR [Node 003] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:54:48.902 DRIVER » [Node 003] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 122 └─[ThermostatSetpointCCGet] payload: 0x02 18:54:48.903 SERIAL » 0x010a00130303430202257afa (12 bytes) 18:54:48.906 SERIAL « [ACK] (0x06) 18:54:48.907 DRIVER ACK received from controller for current transaction 18:54:48.908 SERIAL The receive buffer is empty, waiting for the next chunk... 18:54:48.913 SERIAL « 0x01 (1 bytes) 18:54:48.914 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:54:48.915 SERIAL « 0x04011301e8 (5 bytes) 18:54:48.916 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:54:48.916 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:54:48.916 SERIAL » [ACK] (0x06) 18:54:48.918 SERIAL The receive buffer is empty, waiting for the next chunk... 18:54:48.930 SERIAL « 0x01 (1 bytes) 18:54:48.930 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:54:48.933 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 18:54:48.932 SERIAL « 0x0700137a00000293 (8 bytes) 18:54:48.932 SERIAL Buffer := 0x010700137a00000293 (9 bytes) 18:54:48.933 SERIAL » [ACK] (0x06) 18:54:48.934 SERIAL The receive buffer is empty, waiting for the next chunk... 18:54:48.934 DRIVER ACK received from node for current transaction. RTT = 4730.34 ms 18:54:54.203 DRIVER The awake timeout for node 3 has elapsed. Assuming it is asleep. 18:54:54.203 CNTRLR [Node 003] The node is now asleep. 18:54:54.205 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:54:54.206 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:55:25.850 SERIAL « 0x01 (1 bytes) 18:55:25.851 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:55:25.853 SERIAL « 0x09000400080380034832 (10 bytes) 18:55:25.854 CNTRLR [Node 008] [~] [Battery] level: 72 => 72 [Endpoint 0] 18:55:25.853 SERIAL Buffer := 0x0109000400080380034832 (11 bytes) 18:55:25.858 SERIAL » [ACK] (0x06) 18:55:25.858 SERIAL The receive buffer is empty, waiting for the next chunk... 18:55:25.857 CNTRLR [Node 008] [~] [Battery] isLow: false => false [Endpoint 0] 18:55:25.873 SERIAL « 0x01 (1 bytes) 18:55:25.873 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:55:25.875 CNTRLR [Node 008] [~] [Thermostat Setpoint] setpoint[1]: 4.5 => 4.5 [Endpoint 0] 18:55:25.874 SERIAL « 0x0c00040008064303014201c239 (13 bytes) 18:55:25.874 SERIAL Buffer := 0x010c00040008064303014201c239 (14 bytes) 18:55:25.877 SERIAL » [ACK] (0x06) 18:55:25.878 SERIAL The receive buffer is empty, waiting for the next chunk... 18:55:25.894 SERIAL « 0x01 (1 bytes) 18:55:25.895 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:55:25.899 CNTRLR [Node 008] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:55:25.896 SERIAL « 0x0a00040008044608007fcc (11 bytes) 18:55:25.897 SERIAL Buffer := 0x010a00040008044608007fcc (12 bytes) 18:55:25.903 SERIAL » [ACK] (0x06) 18:55:25.904 SERIAL The receive buffer is empty, waiting for the next chunk... 18:55:25.902 CNTRLR [Node 008] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:55:25.916 SERIAL « 0x01 (1 bytes) 18:55:25.920 CNTRLR [Node 008] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 18:55:25.916 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:55:25.924 CNTRLR [Node 008] [~] [Multilevel Sensor] Air temperature: 19.49 => 19.4 [Endpoint 0] 9 18:55:25.918 SERIAL « 0x0c000400080631050142079d14 (13 bytes) 18:55:25.918 SERIAL Buffer := 0x010c000400080631050142079d14 (14 bytes) 18:55:25.925 SERIAL » [ACK] (0x06) 18:55:25.926 SERIAL The receive buffer is empty, waiting for the next chunk... 18:55:25.943 SERIAL « 0x01 (1 bytes) 18:55:25.944 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:55:25.947 CNTRLR « [Node 008] received wakeup notification 18:55:25.952 DRIVER » [Node 008] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:55:25.945 SERIAL « 0x08000400080284077a (9 bytes) 18:55:25.946 SERIAL Buffer := 0x0108000400080284077a (10 bytes) 18:55:25.947 SERIAL » [ACK] (0x06) 18:55:25.950 SERIAL The receive buffer is empty, waiting for the next chunk... 18:55:25.953 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:55:25.948 CNTRLR [Node 008] The node is now awake. 18:55:25.961 SERIAL « [ACK] (0x06) 18:55:25.962 DRIVER Unexpected ACK received 18:55:25.962 SERIAL The receive buffer is empty, waiting for the next chunk... 18:55:25.967 SERIAL « 0x01 (1 bytes) 18:55:25.967 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:55:25.969 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:55:25.968 SERIAL « 0x04011301e8 (5 bytes) 18:55:25.968 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:55:25.969 SERIAL » [ACK] (0x06) 18:55:25.969 SERIAL The receive buffer is empty, waiting for the next chunk... 18:55:25.982 SERIAL « 0x01 (1 bytes) 18:55:25.983 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:55:25.984 SERIAL « 0x0700138a00000263 (8 bytes) 18:55:25.986 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:55:25.985 SERIAL Buffer := 0x010700138a00000263 (9 bytes) 18:55:25.985 SERIAL » [ACK] (0x06) 18:55:25.987 SERIAL The receive buffer is empty, waiting for the next chunk... 18:55:25.986 DRIVER ACK received from node for current transaction. RTT = 35.14 ms 18:55:27.022 CNTRLR [Node 008] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:55:27.523 DRIVER » [Node 008] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:55:27.523 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:55:27.527 SERIAL « [ACK] (0x06) 18:55:27.528 DRIVER ACK received from controller for current transaction 18:55:27.530 SERIAL The receive buffer is empty, waiting for the next chunk... 18:55:27.534 SERIAL « 0x01 (1 bytes) 18:55:27.534 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:55:27.536 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:55:27.535 SERIAL « 0x04011301e8 (5 bytes) 18:55:27.535 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:55:27.536 SERIAL » [ACK] (0x06) 18:55:27.537 SERIAL The receive buffer is empty, waiting for the next chunk... 18:55:27.550 SERIAL « 0x01 (1 bytes) 18:55:27.551 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:55:27.553 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:55:27.552 SERIAL « 0x0700138a00000263 (8 bytes) 18:55:27.552 SERIAL Buffer := 0x010700138a00000263 (9 bytes) 18:55:27.552 SERIAL » [ACK] (0x06) 18:55:27.554 SERIAL The receive buffer is empty, waiting for the next chunk... 18:55:27.553 DRIVER ACK received from node for current transaction. RTT = 1602.23 ms 18:55:30.156 CNTRLR [Node 008] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:55:30.660 DRIVER » [Node 008] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 138 └─[ThermostatSetpointCCGet] payload: 0x02 18:55:30.661 SERIAL » 0x010a00130803430202258a01 (12 bytes) 18:55:30.671 SERIAL « [ACK] (0x06) 18:55:30.672 DRIVER ACK received from controller for current transaction 18:55:30.672 SERIAL « 0x0601 (2 bytes) 18:55:30.673 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:55:30.682 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:55:30.678 SERIAL « 0x04011301e8 (5 bytes) 18:55:30.679 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:55:30.682 SERIAL » [ACK] (0x06) 18:55:30.683 SERIAL The receive buffer is empty, waiting for the next chunk... 18:55:30.698 SERIAL « 0x010700138a00000263 (9 bytes) 18:55:30.705 DRIVER « [REQ] [SendData] [confirmation] callbackId: 138 transmitStatus: OK 18:55:30.704 SERIAL Buffer := 0x010700138a00000263 (9 bytes) 18:55:30.704 SERIAL » [ACK] (0x06) 18:55:30.708 SERIAL The receive buffer is empty, waiting for the next chunk... 18:55:30.706 DRIVER ACK received from node for current transaction. RTT = 4754.80 ms 18:55:35.949 DRIVER The awake timeout for node 8 has elapsed. Assuming it is asleep. 18:55:35.950 CNTRLR [Node 008] The node is now asleep. 18:55:35.953 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:55:35.953 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:56:13.286 SERIAL « 0x01 (1 bytes) 18:56:13.287 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:56:13.288 SERIAL « 0x09000400020380035020 (10 bytes) 18:56:13.289 CNTRLR [Node 002] [~] [Battery] level: 80 => 80 [Endpoint 0] 18:56:13.288 SERIAL Buffer := 0x0109000400020380035020 (11 bytes) 18:56:13.292 SERIAL » [ACK] (0x06) 18:56:13.293 SERIAL The receive buffer is empty, waiting for the next chunk... 18:56:13.291 CNTRLR [Node 002] [~] [Battery] isLow: false => false [Endpoint 0] 18:56:13.308 SERIAL « 0x01 (1 bytes) 18:56:13.308 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:56:13.311 SERIAL « 0x0c0004000206430301420708ff (13 bytes) 18:56:13.312 CNTRLR [Node 002] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:56:13.311 SERIAL Buffer := 0x010c0004000206430301420708ff (14 bytes) 18:56:13.314 SERIAL » [ACK] (0x06) 18:56:13.314 SERIAL The receive buffer is empty, waiting for the next chunk... 18:56:13.461 SERIAL « 0x01 (1 bytes) 18:56:13.461 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:56:13.463 SERIAL « 0x0a00040002044608007fc6 (11 bytes) 18:56:13.464 CNTRLR [Node 002] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:56:13.463 SERIAL Buffer := 0x010a00040002044608007fc6 (12 bytes) 18:56:13.467 SERIAL » [ACK] (0x06) 18:56:13.468 SERIAL The receive buffer is empty, waiting for the next chunk... 18:56:13.466 CNTRLR [Node 002] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:56:13.481 SERIAL « 0x01 (1 bytes) 18:56:13.482 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:56:13.486 SERIAL « 0x080004000202840770 (9 bytes) 18:56:13.488 CNTRLR « [Node 002] received wakeup notification 18:56:13.490 DRIVER » [Node 002] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:56:13.487 SERIAL Buffer := 0x01080004000202840770 (10 bytes) 18:56:13.487 SERIAL » [ACK] (0x06) 18:56:13.489 SERIAL The receive buffer is empty, waiting for the next chunk... 18:56:13.491 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:56:13.488 CNTRLR [Node 002] The node is now awake. 18:56:13.494 SERIAL « [ACK] (0x06) 18:56:13.495 DRIVER Unexpected ACK received 18:56:13.495 SERIAL The receive buffer is empty, waiting for the next chunk... 18:56:13.501 SERIAL « 0x01 (1 bytes) 18:56:13.502 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:56:13.504 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:56:13.503 SERIAL « 0x04011301e8 (5 bytes) 18:56:13.503 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:56:13.503 SERIAL » [ACK] (0x06) 18:56:13.504 SERIAL The receive buffer is empty, waiting for the next chunk... 18:56:13.517 SERIAL « 0x0107 (2 bytes) 18:56:13.518 SERIAL [incomplete] Buffer := 0x0107 (2 bytes) 18:56:13.520 SERIAL « 0x00134a000003a2 (7 bytes) 18:56:13.521 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:56:13.520 SERIAL Buffer := 0x010700134a000003a2 (9 bytes) 18:56:13.520 SERIAL » [ACK] (0x06) 18:56:13.522 SERIAL The receive buffer is empty, waiting for the next chunk... 18:56:13.521 DRIVER ACK received from node for current transaction. RTT = 31.42 ms 18:56:14.553 CNTRLR [Node 002] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:56:15.054 DRIVER » [Node 002] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:56:15.054 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:56:15.058 SERIAL « [ACK] (0x06) 18:56:15.058 DRIVER ACK received from controller for current transaction 18:56:15.059 SERIAL The receive buffer is empty, waiting for the next chunk... 18:56:15.065 SERIAL « 0x01 (1 bytes) 18:56:15.065 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:56:15.067 SERIAL « 0x04011301e8 (5 bytes) 18:56:15.069 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:56:15.068 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:56:15.068 SERIAL » [ACK] (0x06) 18:56:15.069 SERIAL The receive buffer is empty, waiting for the next chunk... 18:56:15.082 SERIAL « 0x01 (1 bytes) 18:56:15.082 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:56:15.084 SERIAL « 0x0700134a000002a3 (8 bytes) 18:56:15.085 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:56:15.085 DRIVER ACK received from node for current transaction. RTT = 1595.53 ms 18:56:15.084 SERIAL Buffer := 0x010700134a000002a3 (9 bytes) 18:56:15.085 SERIAL » [ACK] (0x06) 18:56:15.086 SERIAL The receive buffer is empty, waiting for the next chunk... 18:56:17.682 CNTRLR [Node 002] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:56:18.183 DRIVER » [Node 002] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 74 └─[ThermostatSetpointCCGet] payload: 0x02 18:56:18.183 SERIAL » 0x010a00130203430202254acb (12 bytes) 18:56:18.188 SERIAL « [ACK] (0x06) 18:56:18.189 DRIVER ACK received from controller for current transaction 18:56:18.189 SERIAL The receive buffer is empty, waiting for the next chunk... 18:56:18.193 SERIAL « 0x01 (1 bytes) 18:56:18.194 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:56:18.195 SERIAL « 0x04011301e8 (5 bytes) 18:56:18.196 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:56:18.196 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:56:18.196 SERIAL » [ACK] (0x06) 18:56:18.197 SERIAL The receive buffer is empty, waiting for the next chunk... 18:56:18.210 SERIAL « 0x01 (1 bytes) 18:56:18.211 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:56:18.212 SERIAL « 0x0700134a000002a3 (8 bytes) 18:56:18.215 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 18:56:18.214 SERIAL Buffer := 0x010700134a000002a3 (9 bytes) 18:56:18.215 SERIAL » [ACK] (0x06) 18:56:18.216 SERIAL The receive buffer is empty, waiting for the next chunk... 18:56:18.216 DRIVER ACK received from node for current transaction. RTT = 4725.81 ms 18:56:23.489 DRIVER The awake timeout for node 2 has elapsed. Assuming it is asleep. 18:56:23.490 CNTRLR [Node 002] The node is now asleep. 18:56:23.493 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:56:23.494 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:57:46.970 SERIAL « 0x01 (1 bytes) 18:57:46.972 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:57:46.977 CNTRLR [Node 005] [~] [Battery] level: 58 => 58 [Endpoint 0] 18:57:46.973 SERIAL « 0x09000400050380033a4d (10 bytes) 18:57:46.973 SERIAL Buffer := 0x0109000400050380033a4d (11 bytes) 18:57:46.980 SERIAL » [ACK] (0x06) 18:57:46.981 SERIAL The receive buffer is empty, waiting for the next chunk... 18:57:46.979 CNTRLR [Node 005] [~] [Battery] isLow: false => false [Endpoint 0] 18:57:46.994 SERIAL « 0x01 (1 bytes) 18:57:46.994 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:57:46.999 SERIAL « 0x0c0004000506430301420708f8 (13 bytes) 18:57:47.001 CNTRLR [Node 005] [~] [Thermostat Setpoint] setpoint[1]: 18 => 18 [Endpoint 0] 18:57:46.999 SERIAL Buffer := 0x010c0004000506430301420708f8 (14 bytes) 18:57:47.002 SERIAL » [ACK] (0x06) 18:57:47.002 SERIAL The receive buffer is empty, waiting for the next chunk... 18:57:47.012 SERIAL « 0x01 (1 bytes) 18:57:47.012 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:57:47.018 CNTRLR [Node 005] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:57:47.015 SERIAL « 0x0a00040005044608007fc1 (11 bytes) 18:57:47.016 SERIAL Buffer := 0x010a00040005044608007fc1 (12 bytes) 18:57:47.022 SERIAL » [ACK] (0x06) 18:57:47.022 SERIAL The receive buffer is empty, waiting for the next chunk... 18:57:47.020 CNTRLR [Node 005] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:57:47.033 SERIAL « 0x01 (1 bytes) 18:57:47.034 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:57:47.036 SERIAL « 0x080004000502840777 (9 bytes) 18:57:47.038 CNTRLR « [Node 005] received wakeup notification 18:57:47.041 DRIVER » [Node 005] [REQ] [SendData] [P: WakeUp] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:57:47.038 CNTRLR [Node 005] The node is now awake. 18:57:47.037 SERIAL Buffer := 0x01080004000502840777 (10 bytes) 18:57:47.038 SERIAL » [ACK] (0x06) 18:57:47.040 SERIAL The receive buffer is empty, waiting for the next chunk... 18:57:47.041 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:57:47.047 SERIAL « [ACK] (0x06) 18:57:47.048 DRIVER Unexpected ACK received 18:57:47.048 SERIAL The receive buffer is empty, waiting for the next chunk... 18:57:47.054 SERIAL « 0x01 (1 bytes) 18:57:47.054 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:57:47.058 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:57:47.055 SERIAL « 0x04011301e8 (5 bytes) 18:57:47.056 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:57:47.057 SERIAL » [ACK] (0x06) 18:57:47.058 SERIAL The receive buffer is empty, waiting for the next chunk... 18:57:47.068 SERIAL « 0x01 (1 bytes) 18:57:47.069 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:57:47.071 SERIAL « 0x07001356000003be (8 bytes) 18:57:47.072 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:57:47.071 SERIAL Buffer := 0x0107001356000003be (9 bytes) 18:57:47.071 SERIAL » [ACK] (0x06) 18:57:47.073 SERIAL The receive buffer is empty, waiting for the next chunk... 18:57:47.072 DRIVER ACK received from node for current transaction. RTT = 32.04 ms 18:57:48.106 CNTRLR [Node 005] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 18:57:48.606 DRIVER » [Node 005] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:57:48.607 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:57:48.611 SERIAL « [ACK] (0x06) 18:57:48.612 DRIVER ACK received from controller for current transaction 18:57:48.612 SERIAL The receive buffer is empty, waiting for the next chunk... 18:57:48.617 SERIAL « 0x01 (1 bytes) 18:57:48.618 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:57:48.620 SERIAL « 0x04011301e8 (5 bytes) 18:57:48.621 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:57:48.621 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:57:48.621 SERIAL » [ACK] (0x06) 18:57:48.622 SERIAL The receive buffer is empty, waiting for the next chunk... 18:57:48.634 SERIAL « 0x01 (1 bytes) 18:57:48.635 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:57:48.636 SERIAL « 0x07001356000002bf (8 bytes) 18:57:48.637 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:57:48.636 SERIAL Buffer := 0x0107001356000002bf (9 bytes) 18:57:48.637 SERIAL » [ACK] (0x06) 18:57:48.638 SERIAL The receive buffer is empty, waiting for the next chunk... 18:57:48.638 DRIVER ACK received from node for current transaction. RTT = 1597.40 ms 18:57:51.236 CNTRLR [Node 005] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 18:57:51.737 DRIVER » [Node 005] [REQ] [SendData] [attempt 3/3] │ transmitOptions: 0x25 │ callbackId: 86 └─[ThermostatSetpointCCGet] payload: 0x02 18:57:51.737 SERIAL » 0x010a001305034302022556d0 (12 bytes) 18:57:51.741 SERIAL « [ACK] (0x06) 18:57:51.741 DRIVER ACK received from controller for current transaction 18:57:51.741 SERIAL The receive buffer is empty, waiting for the next chunk... 18:57:51.747 SERIAL « 0x01 (1 bytes) 18:57:51.748 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:57:51.749 SERIAL « 0x04011301e8 (5 bytes) 18:57:51.750 DRIVER « [RES] [SendData] [confirmation] wasSent: true 18:57:51.749 SERIAL Buffer := 0x0104011301e8 (6 bytes) 18:57:51.750 SERIAL » [ACK] (0x06) 18:57:51.750 SERIAL The receive buffer is empty, waiting for the next chunk... 18:57:51.764 SERIAL « 0x01 (1 bytes) 18:57:51.764 SERIAL [incomplete] Buffer := 0x01 (1 bytes) 18:57:51.766 SERIAL « 0x07001356000002bf (8 bytes) 18:57:51.768 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 18:57:51.767 SERIAL Buffer := 0x0107001356000002bf (9 bytes) 18:57:51.767 SERIAL » [ACK] (0x06) 18:57:51.771 SERIAL The receive buffer is empty, waiting for the next chunk... 18:57:51.768 DRIVER ACK received from node for current transaction. RTT = 4727.91 ms 18:57:57.039 DRIVER The awake timeout for node 5 has elapsed. Assuming it is asleep. 18:57:57.040 CNTRLR [Node 005] The node is now asleep. 18:57:57.042 DRIVER The remaining 6 messages are for sleeping nodes, not sending anything! 18:57:57.043 DRIVER Send queue: (6 messages) · [REQ] SendData (ThermostatSetpointCCGet) [Node 2, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 5, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 6, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 3, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 8, asleep] · [REQ] SendData (ThermostatSetpointCCGet) [Node 4, asleep] 18:58:20.931 DRIVER destroying driver instance...