19:40:51.823 DRIVER ███████╗ ██╗ ██╗ █████╗ ██╗ ██╗ ███████╗ ██╗ ███████╗ ╚══███╔╝ ██║ ██║ ██╔══██╗ ██║ ██║ ██╔════╝ ██║ ██╔════╝ ███╔╝ ██║ █╗ ██║ ███████║ ██║ ██║ █████╗ █████╗ ██║ ███████╗ ███╔╝ ██║███╗██║ ██╔══██║ ╚██╗ ██╔╝ ██╔══╝ ╚════╝ ██ ██║ ╚════██║ ███████╗ ╚███╔███╔╝ ██║ ██║ ╚████╔╝ ███████╗ ╚█████╔╝ ███████║ ╚══════╝ ╚══╝╚══╝ ╚═╝ ╚═╝ ╚═══╝ ╚══════╝ ╚════╝ ╚══════╝ 19:40:51.836 DRIVER version 2.13.0 19:40:51.839 DRIVER 19:40:51.840 DRIVER starting driver... 19:40:51.841 DRIVER opening serial port /dev/ttyACM0 19:40:51.911 DRIVER serial port opened 19:40:52.007 DRIVER Cannot handle message because the driver is not ready to handle it yet. 19:40:51.929 SERIAL » [NAK] (0x15) 19:40:51.972 SERIAL « 0x010f00040029097105000000ff07080050 (17 bytes) 19:40:51.976 SERIAL Buffer := 0x010f00040029097105000000ff07080050 (17 bytes) 19:40:51.994 SERIAL » [ACK] (0x06) 19:40:52.009 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:53.440 DRIVER loading configuration... 19:40:55.830 DRIVER beginning interview... 19:40:55.917 SERIAL » 0x01030015e9 (5 bytes) 19:40:55.839 DRIVER added request handler for AddNodeToNetwork (0x4a)... 1 registered 19:40:55.841 DRIVER added request handler for RemoveNodeFromNetwork (0x4b)... 1 registered 19:40:55.913 DRIVER » [REQ] [GetControllerVersion] [P: Controller] 19:40:55.870 CNTRLR beginning interview... 19:40:55.873 CNTRLR querying version info... 19:40:55.940 SERIAL « [ACK] (0x06) 19:40:55.944 DRIVER ACK received from controller for current transaction 19:40:55.966 CNTRLR received version info: controller type: Static Controller library version: Z-Wave 3.99 19:40:55.968 CNTRLR querying controller IDs... 19:40:55.946 SERIAL « 0x06011001155a2d5761766520332e3939000195 (19 bytes) 19:40:55.948 SERIAL Buffer := 0x011001155a2d5761766520332e3939000195 (18 bytes) 19:40:55.953 SERIAL » [ACK] (0x06) 19:40:55.979 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:55.989 SERIAL » 0x01030020dc (5 bytes) 19:40:55.958 DRIVER « [RES] [GetControllerVersion] [final] payload: 0x5a2d5761766520332e39390001 19:40:55.960 DRIVER ACK already received, resolving transaction 19:40:55.963 DRIVER resuming send queue 19:40:55.987 DRIVER » [REQ] [GetControllerId] [P: Controller] 19:40:55.991 DRIVER The send queue is empty 19:40:56.033 SERIAL « [ACK] (0x06) 19:40:56.036 DRIVER ACK received from controller for current transaction 19:40:56.061 CNTRLR received controller IDs: home ID: 0xdd454af5 own node ID: 1 19:40:56.039 SERIAL « 0x0601080120dd454af501f0 (11 bytes) 19:40:56.041 SERIAL Buffer := 0x01080120dd454af501f0 (10 bytes) 19:40:56.047 SERIAL » [ACK] (0x06) 19:40:56.072 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:56.082 SERIAL » 0x01030005f9 (5 bytes) 19:40:56.051 DRIVER « [RES] [GetControllerId] [final] payload: 0xdd454af501 19:40:56.054 DRIVER ACK already received, resolving transaction 19:40:56.057 DRIVER resuming send queue 19:40:56.080 DRIVER » [REQ] [GetControllerCapabilities] [P: Controller] 19:40:56.084 DRIVER The send queue is empty 19:40:56.065 CNTRLR querying controller capabilities... 19:40:56.089 SERIAL « [ACK] (0x06) 19:40:56.092 DRIVER ACK received from controller for current transaction 19:40:56.108 CNTRLR received controller capabilities: controller role: primary is in other network: false is SIS present: true was real primary: true is a SUC: true 19:40:56.094 SERIAL « 0x06010401051ce3 (7 bytes) 19:40:56.095 SERIAL Buffer := 0x010401051ce3 (6 bytes) 19:40:56.098 SERIAL » [ACK] (0x06) 19:40:56.114 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:56.120 SERIAL » 0x01030007fb (5 bytes) 19:40:56.101 DRIVER « [RES] [GetControllerCapabilities] [final] payload: 0x1c 19:40:56.103 DRIVER ACK already received, resolving transaction 19:40:56.104 DRIVER resuming send queue 19:40:56.119 DRIVER » [REQ] [GetSerialApiCapabilities] [P: Controller] 19:40:56.122 DRIVER The send queue is empty 19:40:56.110 CNTRLR querying API capabilities... 19:40:56.129 SERIAL « [ACK] (0x06) 19:40:56.131 DRIVER ACK received from controller for current transaction 19:40:56.133 SERIAL « 0x06012b01070502011504000001fe83ff88cf1f0000fb9f (23 bytes) 19:40:56.134 SERIAL [incomplete] Buffer := 0x012b01070502011504000001fe83ff88cf1f0000fb (22 bytes) 9f 19:40:56.150 DRIVER « [RES] [GetSerialApiCapabilities] [final] payload: 0x0502011504000001fe83ff88cf1f0000fb9f7da067008080008086000000e8730 0000e0000401a00 19:40:56.164 CNTRLR received API capabilities: serial API version: 5.2 manufacturer ID: 0x0115 product type: 0x0400 product ID: 0x01 supported functions: · GetSerialApiInitData (0x02) · FUNC_ID_SERIAL_API_APPL_NODE_INFORMATION (0x03) · ApplicationCommand (0x04) · GetControllerCapabilities (0x05) · SetSerialApiTimeouts (0x06) · GetSerialApiCapabilities (0x07) · FUNC_ID_SERIAL_API_SOFT_RESET (0x08) · UNKNOWN_FUNC_UNKNOWN_0x09 (0x09) · UNKNOWN_FUNC_UNKNOWN_0x0a (0x0a) · UNKNOWN_FUNC_RF_RECEIVE_MODE (0x10) · UNKNOWN_FUNC_SET_SLEEP_MODE (0x11) · FUNC_ID_ZW_SEND_NODE_INFORMATION (0x12) · SendData (0x13) · UNKNOWN_FUNC_SEND_DATA_MULTI (0x14) · GetControllerVersion (0x15) · UNKNOWN_FUNC_SEND_DATA_ABORT (0x16) · FUNC_ID_ZW_R_F_POWER_LEVEL_SET (0x17) · UNKNOWN_FUNC_SEND_DATA_META (0x18) · FUNC_ID_ZW_GET_RANDOM (0x1c) · GetControllerId (0x20) · UNKNOWN_FUNC_MEMORY_GET_BYTE (0x21) · UNKNOWN_FUNC_MEMORY_PUT_BYTE (0x22) · UNKNOWN_FUNC_MEMORY_GET_BUFFER (0x23) · UNKNOWN_FUNC_MEMORY_PUT_BUFFER (0x24) · UNKNOWN_FUNC_UNKNOWN_0x27 (0x27) · UNKNOWN_FUNC_UNKNOWN_0x28 (0x28) · UNKNOWN_FUNC_UNKNOWN_0x29 (0x29) · UNKNOWN_FUNC_UNKNOWN_0x2a (0x2a) · UNKNOWN_FUNC_UNKNOWN_0x2b (0x2b) · UNKNOWN_FUNC_UNKNOWN_0x2c (0x2c) · UNKNOWN_FUNC_UNKNOWN_0x2d (0x2d) · GetNodeProtocolInfo (0x41) · HardReset (0x42) · FUNC_ID_ZW_REPLICATION_COMMAND_COMPLETE (0x44) · FUNC_ID_ZW_REPLICATION_SEND_DATA (0x45) · FUNC_ID_ZW_ASSIGN_RETURN_ROUTE (0x46) · FUNC_ID_ZW_DELETE_RETURN_ROUTE (0x47) · RequestNodeNeighborUpdate (0x48) · ApplicationUpdateRequest (0x49) · AddNodeToNetwork (0x4a) · RemoveNodeFromNetwork (0x4b) · FUNC_ID_ZW_CREATE_NEW_PRIMARY (0x4c) · FUNC_ID_ZW_CONTROLLER_CHANGE (0x4d) · FUNC_ID_ZW_SET_LEARN_MODE (0x50) · FUNC_ID_ZW_ASSIGN_SUC_RETURN_ROUTE (0x51) · FUNC_ID_ZW_REQUEST_NETWORK_UPDATE (0x53) · FUNC_ID_ZW_SET_SUC_NODE_ID (0x54) · FUNC_ID_ZW_DELETE_SUC_RETURN_ROUTE (0x55) · GetSUCNodeId (0x56) · UNKNOWN_FUNC_SEND_SUC_ID (0x57) · FUNC_ID_ZW_EXPLORE_REQUEST_INCLUSION (0x5e) · RequestNodeInfo (0x60) · RemoveFailedNode (0x61) · IsFailedNode (0x62) · FUNC_ID_ZW_REPLACE_FAILED_NODE (0x63) · UNKNOWN_FUNC_UNKNOWN_0x66 (0x66) · UNKNOWN_FUNC_UNKNOWN_0x67 (0x67) · UNKNOWN_FUNC_UNKNOWN_0x78 (0x78) · GetRoutingInfo (0x80) · UNKNOWN_FUNC_LOCK_ROUTE_RESPONSE (0x90) · UNKNOWN_FUNC_UNKNOWN_0x92 (0x92) · UNKNOWN_FUNC_UNKNOWN_0x93 (0x93) · UNKNOWN_FUNC_UNKNOWN_0x98 (0x98) · UNKNOWN_FUNC_UNKNOWN_0xB4 (0xb4) · UNKNOWN_FUNC_WATCH_DOG_ENABLE (0xb6) · UNKNOWN_FUNC_WATCH_DOG_DISABLE (0xb7) · UNKNOWN_FUNC_WATCH_DOG_KICK (0xb8) · UNKNOWN_FUNC_UNKNOWN_0xB9 (0xb9) · UNKNOWN_FUNC_RF_POWERLEVEL_GET (0xba) · UNKNOWN_FUNC_GET_LIBRARY_TYPE (0xbd) · UNKNOWN_FUNC_SEND_TEST_FRAME (0xbe) · UNKNOWN_FUNC_GET_PROTOCOL_STATUS (0xbf) · UNKNOWN_FUNC_UNKNOWN_0xD2 (0xd2) · UNKNOWN_FUNC_UNKNOWN_0xD3 (0xd3) · UNKNOWN_FUNC_UNKNOWN_0xD4 (0xd4) · UNKNOWN_FUNC_UNKNOWN_0xEF (0xef) · UNKNOWN_FUNC_UNKNOWN_0xF2 (0xf2) · UNKNOWN_FUNC_UNKNOWN_0xF4 (0xf4) · UNKNOWN_FUNC_UNKNOWN_0xF5 (0xf5) 19:40:56.138 SERIAL « 0x7da067008080008086000000e87300000e0000401a0009 (23 bytes) 19:40:56.140 SERIAL Buffer := 0x012b01070502011504000001fe83ff88cf1f0000fb9f7da06700808 (45 bytes) 0008086000000e87300000e0000401a0009 19:40:56.146 SERIAL » [ACK] (0x06) 19:40:56.174 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:56.182 SERIAL » 0x01030056aa (5 bytes) 19:40:56.154 DRIVER ACK already received, resolving transaction 19:40:56.157 DRIVER resuming send queue 19:40:56.180 DRIVER » [REQ] [GetSUCNodeId] [P: Controller] 19:40:56.185 DRIVER The send queue is empty 19:40:56.169 CNTRLR finding SUC... 19:40:56.192 SERIAL « [ACK] (0x06) 19:40:56.194 DRIVER ACK received from controller for current transaction 19:40:56.208 CNTRLR SUC has node ID 1 19:40:56.196 SERIAL « 0x060104015601ad (7 bytes) 19:40:56.197 SERIAL Buffer := 0x0104015601ad (6 bytes) 19:40:56.200 SERIAL » [ACK] (0x06) 19:40:56.215 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:56.222 SERIAL » 0x01030002fe (5 bytes) 19:40:56.202 DRIVER « [RES] [GetSUCNodeId] [final] payload: 0x01 19:40:56.204 DRIVER ACK already received, resolving transaction 19:40:56.206 DRIVER resuming send queue 19:40:56.220 DRIVER » [REQ] [GetSerialApiInitData] [P: Controller] 19:40:56.224 DRIVER The send queue is empty 19:40:56.210 CNTRLR querying node information... 19:40:56.229 SERIAL « [ACK] (0x06) 19:40:56.231 DRIVER ACK received from controller for current transaction 19:40:56.233 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:56.321 SERIAL « 0x0125010205081d05e4dfe07f810000000000000000 (21 bytes) 19:40:56.323 SERIAL [incomplete] Buffer := 0x0125010205081d05e4dfe07f810000000000000000 (21 bytes) 19:40:56.335 DRIVER « [RES] [GetSerialApiInitData] [final] payload: 0x05081d05e4dfe07f8100000000000000000000000000000000000000000000000 500 19:40:56.344 CNTRLR received node information: controller role: primary controller is a SUC: true controller is a slave: false controller supports timers: false nodes in the network: 1, 3, 11, 14, 15, 16, 17, 18, 19, 20, 21, 23, 24 , 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 41, 48 19:40:56.326 SERIAL « 0x0000000000000000000000000000000500ec (18 bytes) 19:40:56.328 SERIAL Buffer := 0x0125010205081d05e4dfe07f8100000000000000000000000000000 (39 bytes) 000000000000000000500ec 19:40:56.333 SERIAL » [ACK] (0x06) 19:40:56.361 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:56.369 SERIAL » 0x01050006640f97 (7 bytes) 19:40:56.337 DRIVER ACK already received, resolving transaction 19:40:56.339 DRIVER resuming send queue 19:40:56.367 DRIVER » [REQ] [SetSerialApiTimeouts] [P: Controller] payload: 0x640f 19:40:56.371 DRIVER The send queue is empty 19:40:56.356 CNTRLR setting serial API timeouts: ack = 1000 ms, byte = 150 ms 19:40:56.376 SERIAL « [ACK] (0x06) 19:40:56.378 DRIVER ACK received from controller for current transaction 19:40:56.394 CNTRLR serial API timeouts overwritten. The old values were: ack = 1000 ms, byte = 15 0 ms 19:40:56.381 SERIAL « 0x0601050106640f96 (8 bytes) 19:40:56.382 SERIAL Buffer := 0x01050106640f96 (7 bytes) 19:40:56.385 SERIAL » [ACK] (0x06) 19:40:56.398 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:56.387 DRIVER « [RES] [SetSerialApiTimeouts] [final] payload: 0x640f 19:40:56.389 DRIVER ACK already received, resolving transaction 19:40:56.391 DRIVER resuming send queue 19:40:56.400 DRIVER driver ready 19:40:56.426 DRIVER The send queue is empty 19:40:56.396 CNTRLR Interview completed 19:40:56.459 SERIAL » 0x0104004101bb (6 bytes) 19:40:56.457 DRIVER » [Node 001] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x01 19:40:56.439 CNTRLR [Node 001] Beginning interview - last completed stage: None 19:40:56.444 CNTRLR [Node 001] new node, doing a full interview... 19:40:56.448 CNTRLR » [Node 001] querying protocol info... 19:40:56.465 SERIAL « [ACK] (0x06) 19:40:56.467 DRIVER ACK received from controller for current transaction 19:40:56.469 SERIAL « 0x06010901419316 (7 bytes) 19:40:56.470 SERIAL [incomplete] Buffer := 0x010901419316 (6 bytes) 19:40:56.485 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x931601020201 19:40:56.495 CNTRLR « [Node 001] received response for protocol info: basic device class: Routing Slave (0x02) generic device class: Static Controller (0x02) specific device class: PC Controller (0x01) is a listening device: true is frequent listening: false is a routing device: false is a secure device: false is a beaming device: true is a listening device: true maximum baud rate: 40000 kbps version: 4 19:40:56.474 SERIAL « 0x0102020133 (5 bytes) 19:40:56.476 SERIAL Buffer := 0x0109014193160102020133 (11 bytes) 19:40:56.483 SERIAL » [ACK] (0x06) 19:40:56.504 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:56.487 DRIVER ACK already received, resolving transaction 19:40:56.490 DRIVER resuming send queue 19:40:56.508 DRIVER The send queue is empty 19:40:58.114 CNTRLR [Node 001] Interview stage completed: ProtocolInfo 19:40:58.152 DRIVER » [Node 001] [REQ] [GetRoutingInfo] [P: Controller] removeNonRepeaters: false removeBadLinks: false 19:40:58.153 SERIAL » 0x010700800100000079 (9 bytes) 19:40:58.121 CNTRLR [Node 001] not querying node info from the controller 19:40:58.123 CNTRLR [Node 001] Interview stage completed: NodeInfo 19:40:58.137 CNTRLR [Node 001] Interview stage completed: CommandClasses 19:40:58.140 CNTRLR [Node 001] Interview stage completed: OverwriteConfig 19:40:58.143 CNTRLR » [Node 001] requesting node neighbors... 19:40:58.159 SERIAL « [ACK] (0x06) 19:40:58.160 DRIVER ACK received from controller for current transaction 19:40:58.162 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:58.173 DRIVER « [RES] [GetRoutingInfo] [final] node ids: 14, 15, 16, 17, 18, 19, 21, 23, 24, 30, 31, 32, 48 19:40:58.177 CNTRLR « [Node 001] node neighbors received: 14, 15, 16, 17, 18, 19, 21, 23, 24, 30, 31, 32, 48 19:40:58.165 SERIAL « 0x0120018000e0d7e00080000000000000000000000000000000000000000000000 (34 bytes) 009 19:40:58.167 SERIAL Buffer := 0x0120018000e0d7e0008000000000000000000000000000000000000 (34 bytes) 0000000000009 19:40:58.170 SERIAL » [ACK] (0x06) 19:40:58.179 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:58.378 SERIAL » 0x0104004103b9 (6 bytes) 19:40:58.174 DRIVER ACK already received, resolving transaction 19:40:58.175 DRIVER resuming send queue 19:40:58.375 DRIVER » [Node 003] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x03 19:40:58.386 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.389 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.392 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.394 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.396 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.398 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.400 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.402 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.403 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.405 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.407 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.409 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.411 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.413 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.415 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.417 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.418 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.421 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.423 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.425 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.427 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.428 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.430 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.432 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.181 CNTRLR [Node 001] Interview stage completed: Neighbors 19:40:58.182 CNTRLR [Node 001] Interview completed 19:40:58.190 CNTRLR [Node 001] The node is ready to be used 19:40:58.193 CNTRLR [Node 001] node is ready 19:40:58.200 CNTRLR [Node 003] Beginning interview - last completed stage: None 19:40:58.201 CNTRLR [Node 003] new node, doing a full interview... 19:40:58.202 CNTRLR » [Node 003] querying protocol info... 19:40:58.204 CNTRLR [Node 011] Beginning interview - last completed stage: None 19:40:58.206 CNTRLR [Node 011] new node, doing a full interview... 19:40:58.206 CNTRLR » [Node 011] querying protocol info... 19:40:58.211 CNTRLR [Node 014] Beginning interview - last completed stage: None 19:40:58.213 CNTRLR [Node 014] new node, doing a full interview... 19:40:58.214 CNTRLR » [Node 014] querying protocol info... 19:40:58.216 CNTRLR [Node 015] Beginning interview - last completed stage: None 19:40:58.217 CNTRLR [Node 015] new node, doing a full interview... 19:40:58.218 CNTRLR » [Node 015] querying protocol info... 19:40:58.220 CNTRLR [Node 016] Beginning interview - last completed stage: None 19:40:58.221 CNTRLR [Node 016] new node, doing a full interview... 19:40:58.222 CNTRLR » [Node 016] querying protocol info... 19:40:58.224 CNTRLR [Node 017] Beginning interview - last completed stage: None 19:40:58.225 CNTRLR [Node 017] new node, doing a full interview... 19:40:58.226 CNTRLR » [Node 017] querying protocol info... 19:40:58.228 CNTRLR [Node 018] Beginning interview - last completed stage: None 19:40:58.229 CNTRLR [Node 018] new node, doing a full interview... 19:40:58.230 CNTRLR » [Node 018] querying protocol info... 19:40:58.232 CNTRLR [Node 019] Beginning interview - last completed stage: None 19:40:58.233 CNTRLR [Node 019] new node, doing a full interview... 19:40:58.234 CNTRLR » [Node 019] querying protocol info... 19:40:58.236 CNTRLR [Node 020] Beginning interview - last completed stage: None 19:40:58.237 CNTRLR [Node 020] new node, doing a full interview... 19:40:58.238 CNTRLR » [Node 020] querying protocol info... 19:40:58.240 CNTRLR [Node 021] Beginning interview - last completed stage: None 19:40:58.241 CNTRLR [Node 021] new node, doing a full interview... 19:40:58.242 CNTRLR » [Node 021] querying protocol info... 19:40:58.244 CNTRLR [Node 023] Beginning interview - last completed stage: None 19:40:58.245 CNTRLR [Node 023] new node, doing a full interview... 19:40:58.246 CNTRLR » [Node 023] querying protocol info... 19:40:58.248 CNTRLR [Node 024] Beginning interview - last completed stage: None 19:40:58.250 CNTRLR [Node 024] new node, doing a full interview... 19:40:58.251 CNTRLR » [Node 024] querying protocol info... 19:40:58.253 CNTRLR [Node 030] Beginning interview - last completed stage: None 19:40:58.254 CNTRLR [Node 030] new node, doing a full interview... 19:40:58.255 CNTRLR » [Node 030] querying protocol info... 19:40:58.258 CNTRLR [Node 031] Beginning interview - last completed stage: None 19:40:58.259 CNTRLR [Node 031] new node, doing a full interview... 19:40:58.261 CNTRLR » [Node 031] querying protocol info... 19:40:58.263 CNTRLR [Node 032] Beginning interview - last completed stage: None 19:40:58.264 CNTRLR [Node 032] new node, doing a full interview... 19:40:58.266 CNTRLR » [Node 032] querying protocol info... 19:40:58.268 CNTRLR [Node 033] Beginning interview - last completed stage: None 19:40:58.269 CNTRLR [Node 033] new node, doing a full interview... 19:40:58.270 CNTRLR » [Node 033] querying protocol info... 19:40:58.272 CNTRLR [Node 034] Beginning interview - last completed stage: None 19:40:58.274 CNTRLR [Node 034] new node, doing a full interview... 19:40:58.275 CNTRLR » [Node 034] querying protocol info... 19:40:58.278 CNTRLR [Node 035] Beginning interview - last completed stage: None 19:40:58.280 CNTRLR [Node 035] new node, doing a full interview... 19:40:58.281 CNTRLR » [Node 035] querying protocol info... 19:40:58.283 CNTRLR [Node 036] Beginning interview - last completed stage: None 19:40:58.284 CNTRLR [Node 036] new node, doing a full interview... 19:40:58.285 CNTRLR » [Node 036] querying protocol info... 19:40:58.287 CNTRLR [Node 037] Beginning interview - last completed stage: None 19:40:58.288 CNTRLR [Node 037] new node, doing a full interview... 19:40:58.289 CNTRLR » [Node 037] querying protocol info... 19:40:58.291 CNTRLR [Node 038] Beginning interview - last completed stage: None 19:40:58.292 CNTRLR [Node 038] new node, doing a full interview... 19:40:58.293 CNTRLR » [Node 038] querying protocol info... 19:40:58.295 CNTRLR [Node 039] Beginning interview - last completed stage: None 19:40:58.296 CNTRLR [Node 039] new node, doing a full interview... 19:40:58.325 CNTRLR » [Node 039] querying protocol info... 19:40:58.331 CNTRLR [Node 041] Beginning interview - last completed stage: None 19:40:58.334 CNTRLR [Node 041] new node, doing a full interview... 19:40:58.337 CNTRLR » [Node 041] querying protocol info... 19:40:58.342 CNTRLR [Node 048] Beginning interview - last completed stage: None 19:40:58.345 CNTRLR [Node 048] new node, doing a full interview... 19:40:58.348 CNTRLR » [Node 048] querying protocol info... 19:40:58.455 SERIAL « [ACK] (0x06) 19:40:58.457 DRIVER ACK received from controller for current transaction 19:40:58.476 CNTRLR « [Node 003] received response for protocol info: basic device class: Static Controller (0x04) generic device class: UNKNOWN (0x07) (0x07) specific device class: UNKNOWN (0x01) (0x01) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 19:40:58.459 SERIAL « 0x0601090141539c010407017a (12 bytes) 19:40:58.461 SERIAL Buffer := 0x01090141539c010407017a (11 bytes) 19:40:58.464 SERIAL » [ACK] (0x06) 19:40:58.520 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:58.541 SERIAL » 0x010400410bb1 (6 bytes) 19:40:58.467 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c01040701 19:40:58.470 DRIVER ACK already received, resolving transaction 19:40:58.472 DRIVER resuming send queue 19:40:58.537 DRIVER » [Node 011] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x0b 19:40:58.543 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.545 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.483 CNTRLR [Node 003] The node is now awake. 19:40:58.521 CNTRLR [Node 003] Interview stage completed: ProtocolInfo 19:40:58.524 CNTRLR » [Node 003] querying node info... 19:40:58.558 SERIAL « [ACK] (0x06) 19:40:58.560 DRIVER ACK received from controller for current transaction 19:40:58.572 CNTRLR « [Node 011] received response for protocol info: basic device class: Static Controller (0x04) generic device class: UNKNOWN (0x07) (0x07) specific device class: UNKNOWN (0x01) (0x01) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 19:40:58.563 SERIAL « 0x0601090141539c010407017a (12 bytes) 19:40:58.564 SERIAL Buffer := 0x01090141539c010407017a (11 bytes) 19:40:58.566 SERIAL » [ACK] (0x06) 19:40:58.582 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:58.594 SERIAL » 0x010400410eb4 (6 bytes) 19:40:58.568 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c01040701 19:40:58.569 DRIVER ACK already received, resolving transaction 19:40:58.570 DRIVER resuming send queue 19:40:58.592 DRIVER » [Node 014] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x0e 19:40:58.595 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.597 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.574 CNTRLR [Node 011] The node is now awake. 19:40:58.584 CNTRLR [Node 011] Interview stage completed: ProtocolInfo 19:40:58.586 CNTRLR » [Node 011] querying node info... 19:40:58.614 SERIAL « [ACK] (0x06) 19:40:58.617 DRIVER ACK received from controller for current transaction 19:40:58.629 CNTRLR « [Node 014] received response for protocol info: basic device class: Static Controller (0x04) generic device class: Binary Switch (0x10) specific device class: not used (0x00) is a listening device: true is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: true maximum baud rate: 40000 kbps version: 4 19:40:58.619 SERIAL « 0x0601090141d39c00041000ed (12 bytes) 19:40:58.621 SERIAL Buffer := 0x01090141d39c00041000ed (11 bytes) 19:40:58.623 SERIAL » [ACK] (0x06) 19:40:58.631 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:58.645 SERIAL » 0x010400600e95 (6 bytes) 19:40:58.624 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0xd39c00041000 19:40:58.626 DRIVER ACK already received, resolving transaction 19:40:58.627 DRIVER resuming send queue 19:40:58.643 DRIVER » [Node 014] [REQ] [RequestNodeInfo] [P: NodeQuery] payload: 0x0e 19:40:58.647 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.632 CNTRLR [Node 014] Interview stage completed: ProtocolInfo 19:40:58.633 CNTRLR » [Node 014] querying node info... 19:40:58.657 SERIAL « [ACK] (0x06) 19:40:58.658 DRIVER ACK received from controller for current transaction 19:40:58.660 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:58.670 DRIVER « [RES] [RequestNodeInfo] [confirmation] payload: 0x01 19:40:58.663 SERIAL « 0x01040160019b (6 bytes) 19:40:58.664 SERIAL Buffer := 0x01040160019b (6 bytes) 19:40:58.667 SERIAL » [ACK] (0x06) 19:40:58.672 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:58.792 SERIAL « 0x01170049840e11041000728670858e2573 (17 bytes) 19:40:58.794 SERIAL [incomplete] Buffer := 0x01170049840e11041000728670858e2573 (17 bytes) 19:40:58.809 DRIVER « [Node 014] [REQ] [ApplicationUpdateRequest] [final] payload: 0x840e11041000728670858e257332317aef253231 19:40:58.812 CNTRLR [Node 014] The node is now awake. 19:40:58.797 SERIAL « 0x32317aef25323147 (8 bytes) 19:40:58.798 SERIAL Buffer := 0x01170049840e11041000728670858e257332317aef25323147 (25 bytes) 19:40:58.806 SERIAL » [ACK] (0x06) 19:40:58.834 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:58.842 SERIAL » 0x010400410fb5 (6 bytes) 19:40:58.823 DRIVER ACK already received, resolving transaction 19:40:58.825 DRIVER resuming send queue 19:40:58.840 DRIVER » [Node 015] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x0f 19:40:58.846 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.829 CNTRLR « [Node 014] node info received supported CCs: · Manufacturer Specific · Version · Configuration · Association · Multi Channel Association · Binary Switch · Powerlevel · Meter · Multilevel Sensor · Firmware Update Meta Data controlled CCs: · Binary Switch · Meter · Multilevel Sensor 19:40:58.909 SERIAL « [ACK] (0x06) 19:40:58.911 DRIVER ACK received from controller for current transaction 19:40:58.921 CNTRLR « [Node 015] received response for protocol info: basic device class: Static Controller (0x04) generic device class: Binary Sensor (0x20) specific device class: Routing Binary Sensor (0x01) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 19:40:58.913 SERIAL « 0x0601090141539c000420015c (12 bytes) 19:40:58.914 SERIAL Buffer := 0x01090141539c000420015c (11 bytes) 19:40:58.915 SERIAL » [ACK] (0x06) 19:40:58.931 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:58.945 SERIAL » 0x0104004110aa (6 bytes) 19:40:58.917 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c00042001 19:40:58.918 DRIVER ACK already received, resolving transaction 19:40:58.919 DRIVER resuming send queue 19:40:58.943 DRIVER » [Node 016] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x10 19:40:58.948 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.949 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:58.923 CNTRLR [Node 015] The node is now awake. 19:40:58.933 CNTRLR [Node 015] Interview stage completed: ProtocolInfo 19:40:58.934 CNTRLR » [Node 015] querying node info... 19:40:58.964 CNTRLR [Node 014] Interview stage completed: NodeInfo 19:40:58.989 CNTRLR [Node 014] ManufacturerSpecificCC: doing a complete interview... 19:40:58.990 CNTRLR » [Node 014] querying manufacturer information... 19:40:59.005 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:59.010 SERIAL « [ACK] (0x06) 19:40:59.023 CNTRLR « [Node 016] received response for protocol info: basic device class: Static Controller (0x04) generic device class: Binary Sensor (0x20) specific device class: Routing Binary Sensor (0x01) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 19:40:59.013 DRIVER ACK received from controller for current transaction 19:40:59.018 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c00042001 19:40:59.020 DRIVER ACK already received, resolving transaction 19:40:59.021 DRIVER resuming send queue 19:40:59.014 SERIAL « 0x0601090141539c000420015c (12 bytes) 19:40:59.015 SERIAL Buffer := 0x01090141539c000420015c (11 bytes) 19:40:59.016 SERIAL » [ACK] (0x06) 19:40:59.034 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:59.052 SERIAL » 0x010900130e0272042501bb (11 bytes) 19:40:59.024 CNTRLR [Node 016] The node is now awake. 19:40:59.036 CNTRLR [Node 016] Interview stage completed: ProtocolInfo 19:40:59.037 CNTRLR » [Node 016] querying node info... 19:40:59.051 DRIVER » [Node 014] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 1 └─[ManufacturerSpecificCCGet] 19:40:59.054 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:59.055 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:59.073 SERIAL « [ACK] (0x06) 19:40:59.075 DRIVER ACK received from controller for current transaction 19:40:59.078 SERIAL « 0x060104011301e8 (7 bytes) 19:40:59.080 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:40:59.082 SERIAL » [ACK] (0x06) 19:40:59.088 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:59.086 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:40:59.103 SERIAL « 0x0107001301000002e8 (9 bytes) 19:40:59.113 DRIVER « [REQ] [SendData] [confirmation] callbackId: 1 transmitStatus: OK 19:40:59.104 SERIAL Buffer := 0x0107001301000002e8 (9 bytes) 19:40:59.108 SERIAL » [ACK] (0x06) 19:40:59.119 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:59.115 DRIVER ACK received from node for current transaction. RTT = 71.95 ms 19:40:59.143 CNTRLR [Node 014] [+] [Manufacturer Specific] manufacturerId: 271 [Endpoint 0] 19:40:59.122 SERIAL « 0x010e0004000e087205010f060010009c (16 bytes) 19:40:59.123 SERIAL Buffer := 0x010e0004000e087205010f060010009c (16 bytes) 19:40:59.185 SERIAL » [ACK] (0x06) 19:40:59.194 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:59.211 SERIAL » 0x0104004111ab (6 bytes) 19:40:59.189 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[ManufacturerSpecificCCReport] payload: 0x010f06001000 19:40:59.191 DRIVER ACK already received, resolving transaction 19:40:59.192 DRIVER resuming send queue 19:40:59.209 DRIVER » [Node 017] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x11 19:40:59.173 CNTRLR [Node 014] [+] [Manufacturer Specific] productType: 1536 [Endpoint 0] 19:40:59.181 CNTRLR [Node 014] [+] [Manufacturer Specific] productId: 4096 [Endpoint 0] 19:40:59.196 CNTRLR « [Node 014] received response for manufacturer information: manufacturer: Fibargroup (0x010f) product type: 0x0600 product id: 0x1000 19:40:59.200 CNTRLR [Node 014] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 19:40:59.262 SERIAL « [ACK] (0x06) 19:40:59.264 DRIVER ACK received from controller for current transaction 19:40:59.281 CNTRLR « [Node 017] received response for protocol info: basic device class: Static Controller (0x04) generic device class: Binary Sensor (0x20) specific device class: Routing Binary Sensor (0x01) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 19:40:59.266 SERIAL « 0x0601090141539c000420015c (12 bytes) 19:40:59.268 SERIAL Buffer := 0x01090141539c000420015c (11 bytes) 19:40:59.271 SERIAL » [ACK] (0x06) 19:40:59.295 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:59.325 SERIAL » 0x0104004112a8 (6 bytes) 19:40:59.273 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c00042001 19:40:59.275 DRIVER ACK already received, resolving transaction 19:40:59.277 DRIVER resuming send queue 19:40:59.323 DRIVER » [Node 018] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x12 19:40:59.328 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:59.330 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:59.284 CNTRLR [Node 017] The node is now awake. 19:40:59.297 CNTRLR [Node 017] Interview stage completed: ProtocolInfo 19:40:59.299 CNTRLR » [Node 017] querying node info... 19:40:59.375 CNTRLR [Node 014] VersionCC: doing a complete interview... 19:40:59.377 CNTRLR » [Node 014] querying node versions... 19:40:59.395 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:59.402 SERIAL « [ACK] (0x06) 19:40:59.412 CNTRLR « [Node 018] received response for protocol info: basic device class: Static Controller (0x04) generic device class: Binary Sensor (0x20) specific device class: Routing Binary Sensor (0x01) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 19:40:59.403 DRIVER ACK received from controller for current transaction 19:40:59.408 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c00042001 19:40:59.409 DRIVER ACK already received, resolving transaction 19:40:59.410 DRIVER resuming send queue 19:40:59.404 SERIAL « 0x0601090141539c000420015c (12 bytes) 19:40:59.405 SERIAL Buffer := 0x01090141539c000420015c (11 bytes) 19:40:59.407 SERIAL » [ACK] (0x06) 19:40:59.423 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:59.441 SERIAL » 0x0104004113a9 (6 bytes) 19:40:59.414 CNTRLR [Node 018] The node is now awake. 19:40:59.424 CNTRLR [Node 018] Interview stage completed: ProtocolInfo 19:40:59.425 CNTRLR » [Node 018] querying node info... 19:40:59.439 DRIVER » [Node 019] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x13 19:40:59.442 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:59.443 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:59.457 SERIAL « [ACK] (0x06) 19:40:59.459 DRIVER ACK received from controller for current transaction 19:40:59.469 CNTRLR « [Node 019] received response for protocol info: basic device class: Static Controller (0x04) generic device class: Binary Switch (0x10) specific device class: not used (0x00) is a listening device: true is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: true maximum baud rate: 40000 kbps version: 4 19:40:59.461 SERIAL « 0x0601090141d39c00041000ed (12 bytes) 19:40:59.462 SERIAL Buffer := 0x01090141d39c00041000ed (11 bytes) 19:40:59.464 SERIAL » [ACK] (0x06) 19:40:59.470 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:59.478 SERIAL » 0x010400601388 (6 bytes) 19:40:59.465 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0xd39c00041000 19:40:59.466 DRIVER ACK already received, resolving transaction 19:40:59.467 DRIVER resuming send queue 19:40:59.477 DRIVER » [Node 019] [REQ] [RequestNodeInfo] [P: NodeQuery] payload: 0x13 19:40:59.480 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:59.471 CNTRLR [Node 019] Interview stage completed: ProtocolInfo 19:40:59.472 CNTRLR » [Node 019] querying node info... 19:40:59.486 SERIAL « [ACK] (0x06) 19:40:59.488 DRIVER ACK received from controller for current transaction 19:40:59.489 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:59.496 DRIVER « [RES] [RequestNodeInfo] [confirmation] payload: 0x01 19:40:59.492 SERIAL « 0x01040160019b (6 bytes) 19:40:59.493 SERIAL Buffer := 0x01040160019b (6 bytes) 19:40:59.495 SERIAL » [ACK] (0x06) 19:40:59.499 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:59.624 SERIAL « 0x01170049841311041000728670858e257332317aef2532315a (25 bytes) 19:40:59.629 DRIVER « [Node 019] [REQ] [ApplicationUpdateRequest] [final] payload: 0x841311041000728670858e257332317aef253231 19:40:59.631 CNTRLR [Node 019] The node is now awake. 19:40:59.625 SERIAL Buffer := 0x01170049841311041000728670858e257332317aef2532315a (25 bytes) 19:40:59.627 SERIAL » [ACK] (0x06) 19:40:59.646 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:59.650 SERIAL » 0x0104004114ae (6 bytes) 19:40:59.640 DRIVER ACK already received, resolving transaction 19:40:59.641 DRIVER resuming send queue 19:40:59.649 DRIVER » [Node 020] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x14 19:40:59.652 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:59.643 CNTRLR « [Node 019] node info received supported CCs: · Manufacturer Specific · Version · Configuration · Association · Multi Channel Association · Binary Switch · Powerlevel · Meter · Multilevel Sensor · Firmware Update Meta Data controlled CCs: · Binary Switch · Meter · Multilevel Sensor 19:40:59.683 SERIAL « [ACK] (0x06) 19:40:59.685 DRIVER ACK received from controller for current transaction 19:40:59.697 CNTRLR « [Node 020] received response for protocol info: basic device class: Static Controller (0x04) generic device class: Binary Sensor (0x20) specific device class: Routing Binary Sensor (0x01) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 19:40:59.687 SERIAL « 0x0601090141539c000420015c (12 bytes) 19:40:59.689 SERIAL Buffer := 0x01090141539c000420015c (11 bytes) 19:40:59.691 SERIAL » [ACK] (0x06) 19:40:59.707 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:59.717 SERIAL » 0x0104004115af (6 bytes) 19:40:59.693 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c00042001 19:40:59.694 DRIVER ACK already received, resolving transaction 19:40:59.695 DRIVER resuming send queue 19:40:59.716 DRIVER » [Node 021] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x15 19:40:59.718 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:59.719 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:59.699 CNTRLR [Node 020] The node is now awake. 19:40:59.709 CNTRLR [Node 020] Interview stage completed: ProtocolInfo 19:40:59.710 CNTRLR » [Node 020] querying node info... 19:40:59.732 CNTRLR [Node 019] Interview stage completed: NodeInfo 19:40:59.743 CNTRLR [Node 019] ManufacturerSpecificCC: doing a complete interview... 19:40:59.745 CNTRLR » [Node 019] querying manufacturer information... 19:40:59.751 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:59.754 SERIAL « [ACK] (0x06) 19:40:59.767 CNTRLR « [Node 021] received response for protocol info: basic device class: Static Controller (0x04) generic device class: Multilevel Switch (0x11) specific device class: Multilevel Power Switch (0x01) is a listening device: true is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: true maximum baud rate: 40000 kbps version: 4 19:40:59.757 DRIVER ACK received from controller for current transaction 19:40:59.763 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0xd39c01041101 19:40:59.764 DRIVER ACK already received, resolving transaction 19:40:59.765 DRIVER resuming send queue 19:40:59.758 SERIAL « 0x0601090141d39c01041101ec (12 bytes) 19:40:59.760 SERIAL Buffer := 0x01090141d39c01041101ec (11 bytes) 19:40:59.762 SERIAL » [ACK] (0x06) 19:40:59.768 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:59.778 SERIAL » 0x01090013130272042502a5 (11 bytes) 19:40:59.770 CNTRLR [Node 021] Interview stage completed: ProtocolInfo 19:40:59.771 CNTRLR » [Node 021] querying node info... 19:40:59.777 DRIVER » [Node 019] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 2 └─[ManufacturerSpecificCCGet] 19:40:59.780 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:59.792 SERIAL « [ACK] (0x06) 19:40:59.794 DRIVER ACK received from controller for current transaction 19:40:59.795 SERIAL « 0x060104011301e8 (7 bytes) 19:40:59.796 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:40:59.798 SERIAL » [ACK] (0x06) 19:40:59.801 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:59.799 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:40:59.809 SERIAL « 0x0107001302000003ea (9 bytes) 19:40:59.814 DRIVER « [REQ] [SendData] [confirmation] callbackId: 2 transmitStatus: OK 19:40:59.810 SERIAL Buffer := 0x0107001302000003ea (9 bytes) 19:40:59.812 SERIAL » [ACK] (0x06) 19:40:59.817 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:59.815 DRIVER ACK received from node for current transaction. RTT = 39.87 ms 19:40:59.826 CNTRLR [Node 019] [+] [Manufacturer Specific] manufacturerId: 271 [Endpoint 0] 19:40:59.821 SERIAL « 0x010e00040013087205010f0600100081 (16 bytes) 19:40:59.822 SERIAL Buffer := 0x010e00040013087205010f0600100081 (16 bytes) 19:40:59.843 SERIAL » [ACK] (0x06) 19:40:59.850 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:59.867 SERIAL » 0x0109001313028611250345 (11 bytes) 19:40:59.846 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[ManufacturerSpecificCCReport] payload: 0x010f06001000 19:40:59.847 DRIVER ACK already received, resolving transaction 19:40:59.849 DRIVER resuming send queue 19:40:59.865 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 3 └─[VersionCCGet] 19:40:59.868 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:59.833 CNTRLR [Node 019] [+] [Manufacturer Specific] productType: 1536 [Endpoint 0] 19:40:59.839 CNTRLR [Node 019] [+] [Manufacturer Specific] productId: 4096 [Endpoint 0] 19:40:59.852 CNTRLR « [Node 019] received response for manufacturer information: manufacturer: Fibargroup (0x010f) product type: 0x0600 product id: 0x1000 19:40:59.855 CNTRLR [Node 019] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 19:40:59.857 CNTRLR [Node 019] VersionCC: doing a complete interview... 19:40:59.859 CNTRLR » [Node 019] querying node versions... 19:40:59.880 SERIAL « [ACK] (0x06) 19:40:59.882 DRIVER ACK received from controller for current transaction 19:40:59.884 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:59.897 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:40:59.890 SERIAL « 0x0104011301e8 (6 bytes) 19:40:59.892 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:40:59.894 SERIAL » [ACK] (0x06) 19:40:59.899 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:59.925 SERIAL « 0x0107001303000003eb (9 bytes) 19:40:59.932 DRIVER « [REQ] [SendData] [confirmation] callbackId: 3 transmitStatus: OK 19:40:59.927 SERIAL Buffer := 0x0107001303000003eb (9 bytes) 19:40:59.929 SERIAL » [ACK] (0x06) 19:40:59.937 SERIAL The receive buffer is empty, waiting for the next chunk... 19:40:59.934 DRIVER ACK received from node for current transaction. RTT = 69.85 ms 19:40:59.962 CNTRLR [Node 019] [+] [Version] libraryType: 3 [Endpoint 0] 19:40:59.948 SERIAL « 0x010d00040013078612030334191942 (15 bytes) 19:40:59.950 SERIAL Buffer := 0x010d00040013078612030334191942 (15 bytes) 19:40:59.982 SERIAL » [ACK] (0x06) 19:40:59.990 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.027 SERIAL » 0x010a00131303861372250430 (12 bytes) 19:40:59.985 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[VersionCCReport] payload: 0x0303341919 19:40:59.987 DRIVER ACK already received, resolving transaction 19:40:59.988 DRIVER resuming send queue 19:41:00.025 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 4 └─[VersionCCCommandClassGet] payload: 0x72 19:41:00.030 DRIVER workOffSendQueue > skipping because a transaction is pending 19:40:59.970 CNTRLR [Node 019] [+] [Version] protocolVersion: "3.52" [Endpoint 0] 19:40:59.978 CNTRLR [Node 019] [+] [Version] firmwareVersions: 25.25 [Endpoint 0] 19:40:59.992 CNTRLR « [Node 019] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 3.52 firmware versions: 25.25 19:40:59.994 CNTRLR » [Node 019] querying CC versions... 19:40:59.997 CNTRLR » [Node 019] querying the CC version for Manufacturer Specific (0x72)... 19:41:00.042 SERIAL « [ACK] (0x06) 19:41:00.044 DRIVER ACK received from controller for current transaction 19:41:00.048 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.057 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:00.051 SERIAL « 0x0104011301e8 (6 bytes) 19:41:00.053 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:00.054 SERIAL » [ACK] (0x06) 19:41:00.059 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.078 DRIVER « [REQ] [SendData] [confirmation] callbackId: 4 transmitStatus: OK 19:41:00.070 SERIAL « 0x0107001304000002ed (9 bytes) 19:41:00.072 SERIAL Buffer := 0x0107001304000002ed (9 bytes) 19:41:00.075 SERIAL » [ACK] (0x06) 19:41:00.082 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.080 DRIVER ACK received from node for current transaction. RTT = 62.68 ms 19:41:00.106 CNTRLR [Node 019] supports CC Manufacturer Specific (0x72) in version 1 19:41:00.095 SERIAL « 0x010a00040013048614720107 (12 bytes) 19:41:00.096 SERIAL Buffer := 0x010a00040013048614720107 (12 bytes) 19:41:00.100 SERIAL » [ACK] (0x06) 19:41:00.105 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.124 SERIAL » 0x010a001313038613862505c5 (12 bytes) 19:41:00.101 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x7201 19:41:00.103 DRIVER ACK already received, resolving transaction 19:41:00.103 DRIVER resuming send queue 19:41:00.121 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 5 └─[VersionCCCommandClassGet] payload: 0x86 19:41:00.125 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:00.109 CNTRLR » [Node 019] querying the CC version for Version (0x86)... 19:41:00.142 SERIAL « [ACK] (0x06) 19:41:00.145 DRIVER ACK received from controller for current transaction 19:41:00.147 SERIAL « 0x060104011301e8 (7 bytes) 19:41:00.148 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:00.149 SERIAL » [ACK] (0x06) 19:41:00.152 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.151 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:00.162 SERIAL « 0x0107001305000002ec (9 bytes) 19:41:00.166 DRIVER « [REQ] [SendData] [confirmation] callbackId: 5 transmitStatus: OK 19:41:00.163 SERIAL Buffer := 0x0107001305000002ec (9 bytes) 19:41:00.164 SERIAL » [ACK] (0x06) 19:41:00.168 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.167 DRIVER ACK received from node for current transaction. RTT = 47.55 ms 19:41:00.181 CNTRLR [Node 019] supports CC Version (0x86) in version 1 19:41:00.171 SERIAL « 0x010a000400130486148601f3 (12 bytes) 19:41:00.172 SERIAL Buffer := 0x010a000400130486148601f3 (12 bytes) 19:41:00.174 SERIAL » [ACK] (0x06) 19:41:00.179 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.188 SERIAL » 0x010a00131303861370250630 (12 bytes) 19:41:00.176 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8601 19:41:00.177 DRIVER ACK already received, resolving transaction 19:41:00.178 DRIVER resuming send queue 19:41:00.187 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 6 └─[VersionCCCommandClassGet] payload: 0x70 19:41:00.190 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:00.182 CNTRLR » [Node 019] querying the CC version for Configuration (0x70)... 19:41:00.194 SERIAL « [ACK] (0x06) 19:41:00.196 DRIVER ACK received from controller for current transaction 19:41:00.197 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.201 SERIAL « 0x0104011301e8 (6 bytes) 19:41:00.204 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:00.202 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:00.203 SERIAL » [ACK] (0x06) 19:41:00.206 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.217 SERIAL « 0x0107001306000003ee (9 bytes) 19:41:00.221 DRIVER « [REQ] [SendData] [confirmation] callbackId: 6 transmitStatus: OK 19:41:00.218 SERIAL Buffer := 0x0107001306000003ee (9 bytes) 19:41:00.220 SERIAL » [ACK] (0x06) 19:41:00.224 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.222 DRIVER ACK received from node for current transaction. RTT = 36.10 ms 19:41:00.252 CNTRLR [Node 019] supports CC Configuration (0x70) in version 1 19:41:00.241 SERIAL « 0x010a00040013048614700105 (12 bytes) 19:41:00.242 SERIAL Buffer := 0x010a00040013048614700105 (12 bytes) 19:41:00.244 SERIAL » [ACK] (0x06) 19:41:00.250 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.260 SERIAL » 0x010a001313038613852507c4 (12 bytes) 19:41:00.246 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x7001 19:41:00.247 DRIVER ACK already received, resolving transaction 19:41:00.248 DRIVER resuming send queue 19:41:00.259 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 7 └─[VersionCCCommandClassGet] payload: 0x85 19:41:00.262 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:00.253 CNTRLR » [Node 019] querying the CC version for Association (0x85)... 19:41:00.267 SERIAL « [ACK] (0x06) 19:41:00.269 DRIVER ACK received from controller for current transaction 19:41:00.270 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.273 SERIAL « 0x0104011301e8 (6 bytes) 19:41:00.277 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:00.274 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:00.276 SERIAL » [ACK] (0x06) 19:41:00.279 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.290 SERIAL « 0x0107001307000002ee (9 bytes) 19:41:00.294 DRIVER « [REQ] [SendData] [confirmation] callbackId: 7 transmitStatus: OK 19:41:00.291 SERIAL Buffer := 0x0107001307000002ee (9 bytes) 19:41:00.292 SERIAL » [ACK] (0x06) 19:41:00.296 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.295 DRIVER ACK received from node for current transaction. RTT = 37.29 ms 19:41:00.300 SERIAL « 0x010a000400130486 (8 bytes) 19:41:00.301 SERIAL [incomplete] Buffer := 0x010a000400130486 (8 bytes) 19:41:00.308 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8502 19:41:00.313 CNTRLR [Node 019] supports CC Association (0x85) in version 2 19:41:00.303 SERIAL « 0x148502f3 (4 bytes) 19:41:00.304 SERIAL Buffer := 0x010a000400130486148502f3 (12 bytes) 19:41:00.306 SERIAL » [ACK] (0x06) 19:41:00.312 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.320 SERIAL » 0x010a0013130386138e2508c0 (12 bytes) 19:41:00.309 DRIVER ACK already received, resolving transaction 19:41:00.310 DRIVER resuming send queue 19:41:00.319 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 8 └─[VersionCCCommandClassGet] payload: 0x8e 19:41:00.321 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:00.314 CNTRLR » [Node 019] querying the CC version for Multi Channel Association (0x8e)... 19:41:00.326 SERIAL « [ACK] (0x06) 19:41:00.327 DRIVER ACK received from controller for current transaction 19:41:00.328 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.332 SERIAL « 0x0104011301e8 (6 bytes) 19:41:00.336 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:00.333 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:00.335 SERIAL » [ACK] (0x06) 19:41:00.337 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.349 SERIAL « 0x0107001308000002e1 (9 bytes) 19:41:00.353 DRIVER « [REQ] [SendData] [confirmation] callbackId: 8 transmitStatus: OK 19:41:00.350 SERIAL Buffer := 0x0107001308000002e1 (9 bytes) 19:41:00.351 SERIAL » [ACK] (0x06) 19:41:00.355 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.354 DRIVER ACK received from node for current transaction. RTT = 36.01 ms 19:41:00.359 SERIAL « 0x010a000400130486148e02f8 (12 bytes) 19:41:00.364 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8e02 19:41:00.368 CNTRLR [Node 019] supports CC Multi Channel Association (0x8e) in version 2 19:41:00.360 SERIAL Buffer := 0x010a000400130486148e02f8 (12 bytes) 19:41:00.362 SERIAL » [ACK] (0x06) 19:41:00.367 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.375 SERIAL » 0x010a0013130386132525096a (12 bytes) 19:41:00.365 DRIVER ACK already received, resolving transaction 19:41:00.366 DRIVER resuming send queue 19:41:00.374 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 9 └─[VersionCCCommandClassGet] payload: 0x25 19:41:00.377 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:00.370 CNTRLR » [Node 019] querying the CC version for Binary Switch (0x25)... 19:41:00.382 SERIAL « [ACK] (0x06) 19:41:00.383 DRIVER ACK received from controller for current transaction 19:41:00.384 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.387 SERIAL « 0x0104011301e8 (6 bytes) 19:41:00.391 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:00.388 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:00.390 SERIAL » [ACK] (0x06) 19:41:00.392 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.404 SERIAL « 0x0107001309000002e0 (9 bytes) 19:41:00.408 DRIVER « [REQ] [SendData] [confirmation] callbackId: 9 transmitStatus: OK 19:41:00.406 SERIAL Buffer := 0x0107001309000002e0 (9 bytes) 19:41:00.407 SERIAL » [ACK] (0x06) 19:41:00.411 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.410 DRIVER ACK received from node for current transaction. RTT = 36.43 ms 19:41:00.416 SERIAL « 0x010a00040013048614250150 (12 bytes) 19:41:00.421 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x2501 19:41:00.425 CNTRLR [Node 019] supports CC Binary Switch (0x25) in version 1 19:41:00.417 SERIAL Buffer := 0x010a00040013048614250150 (12 bytes) 19:41:00.419 SERIAL » [ACK] (0x06) 19:41:00.424 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.433 SERIAL » 0x010a00131303861332250a7e (12 bytes) 19:41:00.422 DRIVER ACK already received, resolving transaction 19:41:00.423 DRIVER resuming send queue 19:41:00.432 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 10 └─[VersionCCCommandClassGet] payload: 0x32 19:41:00.435 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:00.427 CNTRLR [Node 019] skipping query for Powerlevel (0x73) because max implemented vers ion is 0 19:41:00.428 CNTRLR » [Node 019] querying the CC version for Meter (0x32)... 19:41:00.439 SERIAL « [ACK] (0x06) 19:41:00.440 DRIVER ACK received from controller for current transaction 19:41:00.441 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.445 SERIAL « 0x0104011301e8 (6 bytes) 19:41:00.449 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:00.446 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:00.447 SERIAL » [ACK] (0x06) 19:41:00.450 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.463 SERIAL « 0x010700130a000002e3 (9 bytes) 19:41:00.466 DRIVER « [REQ] [SendData] [confirmation] callbackId: 10 transmitStatus: OK 19:41:00.464 SERIAL Buffer := 0x010700130a000002e3 (9 bytes) 19:41:00.465 SERIAL » [ACK] (0x06) 19:41:00.469 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.468 DRIVER ACK received from node for current transaction. RTT = 36.11 ms 19:41:00.473 SERIAL « 0x010a0004001304 (7 bytes) 19:41:00.474 SERIAL [incomplete] Buffer := 0x010a0004001304 (7 bytes) 19:41:00.480 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x3202 19:41:00.485 CNTRLR [Node 019] supports CC Meter (0x32) in version 2 19:41:00.476 SERIAL « 0x8614320244 (5 bytes) 19:41:00.476 SERIAL Buffer := 0x010a00040013048614320244 (12 bytes) 19:41:00.478 SERIAL » [ACK] (0x06) 19:41:00.484 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.491 SERIAL » 0x010a00131303861331250b7c (12 bytes) 19:41:00.481 DRIVER ACK already received, resolving transaction 19:41:00.482 DRIVER resuming send queue 19:41:00.490 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 11 └─[VersionCCCommandClassGet] payload: 0x31 19:41:00.493 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:00.486 CNTRLR » [Node 019] querying the CC version for Multilevel Sensor (0x31)... 19:41:00.497 SERIAL « [ACK] (0x06) 19:41:00.498 DRIVER ACK received from controller for current transaction 19:41:00.499 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.503 SERIAL « 0x0104011301e8 (6 bytes) 19:41:00.507 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:00.505 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:00.506 SERIAL » [ACK] (0x06) 19:41:00.509 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.521 SERIAL « 0x010700130b000002e2 (9 bytes) 19:41:00.525 DRIVER « [REQ] [SendData] [confirmation] callbackId: 11 transmitStatus: OK 19:41:00.523 SERIAL Buffer := 0x010700130b000002e2 (9 bytes) 19:41:00.524 SERIAL » [ACK] (0x06) 19:41:00.528 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.526 DRIVER ACK received from node for current transaction. RTT = 36.74 ms 19:41:00.531 SERIAL « 0x010a00040013048614310247 (12 bytes) 19:41:00.536 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x3102 19:41:00.541 CNTRLR [Node 019] supports CC Multilevel Sensor (0x31) in version 2 19:41:00.532 SERIAL Buffer := 0x010a00040013048614310247 (12 bytes) 19:41:00.534 SERIAL » [ACK] (0x06) 19:41:00.540 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.581 SERIAL » 0x01040060158e (6 bytes) 19:41:00.537 DRIVER ACK already received, resolving transaction 19:41:00.538 DRIVER resuming send queue 19:41:00.579 DRIVER » [Node 021] [REQ] [RequestNodeInfo] [P: NodeQuery] payload: 0x15 19:41:00.542 CNTRLR [Node 019] skipping query for Firmware Update Meta Data (0x7a) because max i mplemented version is 0 19:41:00.545 CNTRLR [Node 019] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 19:41:00.548 CNTRLR [Node 019] trying to load device config 19:41:00.586 SERIAL « [ACK] (0x06) 19:41:00.588 DRIVER ACK received from controller for current transaction 19:41:00.589 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.595 DRIVER « [RES] [RequestNodeInfo] [confirmation] payload: 0x01 19:41:00.592 SERIAL « 0x01040160019b (6 bytes) 19:41:00.593 SERIAL Buffer := 0x01040160019b (6 bytes) 19:41:00.594 SERIAL » [ACK] (0x06) 19:41:00.598 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.695 CNTRLR [Node 019] device config loaded 19:41:00.746 SERIAL « 0x011a00498415140411015e86725a732027252632858e5970ef202643 (28 bytes) 19:41:00.751 DRIVER « [Node 021] [REQ] [ApplicationUpdateRequest] [final] payload: 0x8415140411015e86725a732027252632858e5970ef2026 19:41:00.753 CNTRLR [Node 021] The node is now awake. 19:41:00.748 SERIAL Buffer := 0x011a00498415140411015e86725a732027252632858e5970ef20264 (28 bytes) 3 19:41:00.750 SERIAL » [ACK] (0x06) 19:41:00.765 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:00.802 SERIAL » 0x0109001315027204250cad (11 bytes) 19:41:00.761 DRIVER ACK already received, resolving transaction 19:41:00.762 DRIVER resuming send queue 19:41:00.801 DRIVER » [Node 021] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 12 └─[ManufacturerSpecificCCGet] 19:41:00.804 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:00.805 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:00.764 CNTRLR « [Node 021] node info received supported CCs: · Z-Wave Plus Info · Version · Manufacturer Specific · Device Reset Locally · Powerlevel · Basic · All Switch · Binary Switch · Multilevel Switch · Meter · Association · Multi Channel Association · Association Group Information · Configuration controlled CCs: · Basic · Multilevel Switch 19:41:00.766 CNTRLR [Node 021] Interview stage completed: NodeInfo 19:41:00.795 CNTRLR [Node 021] ManufacturerSpecificCC: doing a complete interview... 19:41:00.797 CNTRLR » [Node 021] querying manufacturer information... 19:41:00.816 CNTRLR [Node 019] ConfigurationCC: Loading configuration parameters from device confi g 19:41:00.823 CNTRLR [Node 019] [+] [Configuration] isParamInformationFromConfig: false [internal] 19:41:00.835 CNTRLR [Node 019] [Configuration] 1: metadata updated 19:41:00.849 CNTRLR [Node 019] [Configuration] 16: metadata updated 19:41:00.856 CNTRLR [Node 019] [Configuration] 34: metadata updated 19:41:00.863 CNTRLR [Node 019] [Configuration] 35: metadata updated 19:41:00.871 CNTRLR [Node 019] [Configuration] 39: metadata updated 19:41:00.879 CNTRLR [Node 019] [Configuration] 40: metadata updated 19:41:00.885 CNTRLR [Node 019] [Configuration] 42: metadata updated 19:41:00.893 CNTRLR [Node 019] [Configuration] 43: metadata updated 19:41:00.901 CNTRLR [Node 019] [Configuration] 45: metadata updated 19:41:00.908 CNTRLR [Node 019] [Configuration] 47: metadata updated 19:41:00.916 CNTRLR [Node 019] [Configuration] 49: metadata updated 19:41:00.922 CNTRLR [Node 019] [Configuration] 50: metadata updated 19:41:00.928 CNTRLR [Node 019] [Configuration] 51: metadata updated 19:41:00.935 CNTRLR [Node 019] [Configuration] 52: metadata updated 19:41:00.940 CNTRLR [Node 019] [Configuration] 60: metadata updated 19:41:00.946 CNTRLR [Node 019] [Configuration] 61: metadata updated 19:41:00.952 CNTRLR [Node 019] [Configuration] 62: metadata updated 19:41:00.963 CNTRLR [Node 019] [Configuration] 63: metadata updated 19:41:00.970 CNTRLR [Node 019] [Configuration] 70: metadata updated 19:41:00.977 CNTRLR [Node 019] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 19:41:00.982 CNTRLR » [Node 019] querying parameter #1 value... 19:41:00.990 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:00.992 SERIAL « [ACK] (0x06) 19:41:00.993 DRIVER ACK received from controller for current transaction 19:41:00.997 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:00.994 SERIAL « 0x060104011301e8 (7 bytes) 19:41:00.995 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:00.996 SERIAL » [ACK] (0x06) 19:41:00.998 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:01.042 DRIVER « [REQ] [SendData] [confirmation] callbackId: 12 transmitStatus: OK 19:41:01.045 DRIVER ACK received from node for current transaction. RTT = 244.04 ms 19:41:01.036 SERIAL « 0x010700130c000003e4 (9 bytes) 19:41:01.038 SERIAL Buffer := 0x010700130c000003e4 (9 bytes) 19:41:01.040 SERIAL » [ACK] (0x06) 19:41:01.050 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:01.205 CNTRLR [Node 021] [+] [Manufacturer Specific] manufacturerId: 345 [Endpoint 0] 19:41:01.227 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[ManufacturerSpecificCCReport] payload: 0x015900010052 19:41:01.228 DRIVER ACK already received, resolving transaction 19:41:01.230 DRIVER resuming send queue 19:41:01.196 SERIAL « 0x010e0004001508720501590001005294 (16 bytes) 19:41:01.198 SERIAL Buffer := 0x010e0004001508720501590001005294 (16 bytes) 19:41:01.225 SERIAL » [ACK] (0x06) 19:41:01.231 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:01.286 SERIAL » 0x0104004117ad (6 bytes) 19:41:01.214 CNTRLR [Node 021] [+] [Manufacturer Specific] productType: 1 [Endpoint 0] 19:41:01.221 CNTRLR [Node 021] [+] [Manufacturer Specific] productId: 82 [Endpoint 0] 19:41:01.232 CNTRLR « [Node 021] received response for manufacturer information: manufacturer: Goap (0x0159) product type: 0x01 product id: 0x52 19:41:01.234 CNTRLR [Node 021] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 19:41:01.237 CNTRLR [Node 021] VersionCC: doing a complete interview... 19:41:01.238 CNTRLR » [Node 021] querying node versions... 19:41:01.284 DRIVER » [Node 023] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x17 19:41:01.287 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:01.350 SERIAL « [ACK] (0x06) 19:41:01.353 DRIVER ACK received from controller for current transaction 19:41:01.366 CNTRLR « [Node 023] received response for protocol info: basic device class: Static Controller (0x04) generic device class: Entry Control (0x40) specific device class: not used (0x00) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 19:41:01.354 SERIAL « 0x0601090141539c000440003d (12 bytes) 19:41:01.356 SERIAL Buffer := 0x01090141539c000440003d (11 bytes) 19:41:01.357 SERIAL » [ACK] (0x06) 19:41:01.382 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:01.412 SERIAL » 0x0104004118a2 (6 bytes) 19:41:01.359 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c00044000 19:41:01.361 DRIVER ACK already received, resolving transaction 19:41:01.363 DRIVER resuming send queue 19:41:01.409 DRIVER » [Node 024] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x18 19:41:01.419 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:01.420 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:01.368 CNTRLR [Node 023] The node is now awake. 19:41:01.383 CNTRLR [Node 023] Interview stage completed: ProtocolInfo 19:41:01.387 CNTRLR » [Node 023] querying node info... 19:41:01.455 SERIAL « [ACK] (0x06) 19:41:01.458 DRIVER ACK received from controller for current transaction 19:41:01.477 CNTRLR « [Node 024] received response for protocol info: basic device class: Static Controller (0x04) generic device class: Binary Sensor (0x20) specific device class: Routing Binary Sensor (0x01) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 19:41:01.461 SERIAL « 0x0601090141539c000420015c (12 bytes) 19:41:01.463 SERIAL Buffer := 0x01090141539c000420015c (11 bytes) 19:41:01.466 SERIAL » [ACK] (0x06) 19:41:01.493 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:01.514 SERIAL » 0x010400411ea4 (6 bytes) 19:41:01.468 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c00042001 19:41:01.472 DRIVER ACK already received, resolving transaction 19:41:01.475 DRIVER resuming send queue 19:41:01.512 DRIVER » [Node 030] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x1e 19:41:01.516 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:01.480 CNTRLR [Node 024] The node is now awake. 19:41:01.595 SERIAL « [ACK] (0x06) 19:41:01.597 DRIVER ACK received from controller for current transaction 19:41:01.609 CNTRLR « [Node 030] received response for protocol info: basic device class: Static Controller (0x04) generic device class: Binary Sensor (0x20) specific device class: Routing Binary Sensor (0x01) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 19:41:01.599 SERIAL « 0x0601090141539c000420015c (12 bytes) 19:41:01.600 SERIAL Buffer := 0x01090141539c000420015c (11 bytes) 19:41:01.603 SERIAL » [ACK] (0x06) 19:41:01.636 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:01.646 SERIAL » 0x010400411fa5 (6 bytes) 19:41:01.605 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c00042001 19:41:01.606 DRIVER ACK already received, resolving transaction 19:41:01.607 DRIVER resuming send queue 19:41:01.645 DRIVER » [Node 031] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x1f 19:41:01.647 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:01.648 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:01.611 CNTRLR [Node 030] The node is now awake. 19:41:01.638 CNTRLR [Node 030] Interview stage completed: ProtocolInfo 19:41:01.639 CNTRLR » [Node 030] querying node info... 19:41:01.666 CNTRLR [Node 024] Interview stage completed: ProtocolInfo 19:41:01.667 CNTRLR » [Node 024] querying node info... 19:41:01.672 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:01.675 SERIAL « [ACK] (0x06) 19:41:01.695 CNTRLR « [Node 031] received response for protocol info: basic device class: Static Controller (0x04) generic device class: Binary Sensor (0x20) specific device class: Routing Binary Sensor (0x01) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 19:41:01.677 DRIVER ACK received from controller for current transaction 19:41:01.689 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c00042001 19:41:01.691 DRIVER ACK already received, resolving transaction 19:41:01.692 DRIVER resuming send queue 19:41:01.678 SERIAL « 0x0601090141539c000420015c (12 bytes) 19:41:01.681 SERIAL Buffer := 0x01090141539c000420015c (11 bytes) 19:41:01.685 SERIAL » [ACK] (0x06) 19:41:01.727 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:01.744 SERIAL » 0x01040041209a (6 bytes) 19:41:01.698 CNTRLR [Node 031] The node is now awake. 19:41:01.730 CNTRLR [Node 031] Interview stage completed: ProtocolInfo 19:41:01.734 CNTRLR » [Node 031] querying node info... 19:41:01.741 DRIVER » [Node 032] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x20 19:41:01.747 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:01.753 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:01.765 SERIAL « [ACK] (0x06) 19:41:01.768 DRIVER ACK received from controller for current transaction 19:41:01.788 CNTRLR « [Node 032] received response for protocol info: basic device class: Static Controller (0x04) generic device class: Binary Switch (0x10) specific device class: Binary Power Switch (0x01) is a listening device: true is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: true maximum baud rate: 40000 kbps version: 4 19:41:01.771 SERIAL « 0x0601090141d39c01041001ed (12 bytes) 19:41:01.773 SERIAL Buffer := 0x01090141d39c01041001ed (11 bytes) 19:41:01.776 SERIAL » [ACK] (0x06) 19:41:01.791 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:01.803 SERIAL » 0x0104006020bb (6 bytes) 19:41:01.779 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0xd39c01041001 19:41:01.781 DRIVER ACK already received, resolving transaction 19:41:01.785 DRIVER resuming send queue 19:41:01.801 DRIVER » [Node 032] [REQ] [RequestNodeInfo] [P: NodeQuery] payload: 0x20 19:41:01.806 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:01.793 CNTRLR [Node 032] Interview stage completed: ProtocolInfo 19:41:01.795 CNTRLR » [Node 032] querying node info... 19:41:01.833 SERIAL « [ACK] (0x06) 19:41:01.836 DRIVER ACK received from controller for current transaction 19:41:01.839 SERIAL « 0x0601040160019b (7 bytes) 19:41:01.840 SERIAL Buffer := 0x01040160019b (6 bytes) 19:41:01.843 SERIAL » [ACK] (0x06) 19:41:01.850 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:01.845 DRIVER « [RES] [RequestNodeInfo] [confirmation] payload: 0x01 19:41:06.020 SERIAL « 0x0106004981000031 (8 bytes) 19:41:06.029 DRIVER « [REQ] [ApplicationUpdateRequest] [fatal_node] payload: 0x810000 19:41:06.035 CNTRLR [Node 032] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 19:41:06.023 SERIAL Buffer := 0x0106004981000031 (8 bytes) 19:41:06.026 SERIAL » [ACK] (0x06) 19:41:06.037 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:06.537 DRIVER » [Node 032] [REQ] [RequestNodeInfo] [attempt 2/3] payload: 0x20 19:41:06.539 SERIAL » 0x0104006020bb (6 bytes) 19:41:06.544 SERIAL « [ACK] (0x06) 19:41:06.546 DRIVER ACK received from controller for current transaction 19:41:06.547 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:06.553 SERIAL « 0x01040160019b (6 bytes) 19:41:06.558 DRIVER « [RES] [RequestNodeInfo] [confirmation] payload: 0x01 19:41:06.554 SERIAL Buffer := 0x01040160019b (6 bytes) 19:41:06.556 SERIAL » [ACK] (0x06) 19:41:06.560 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:08.502 DRIVER The awake timeout for node 3 has elapsed. Assuming it is asleep. 19:41:08.504 CNTRLR [Node 003] The node is now asleep. 19:41:08.519 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:08.576 DRIVER The awake timeout for node 11 has elapsed. Assuming it is asleep. 19:41:08.578 CNTRLR [Node 011] The node is now asleep. 19:41:08.593 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:08.925 DRIVER The awake timeout for node 15 has elapsed. Assuming it is asleep. 19:41:08.927 CNTRLR [Node 015] The node is now asleep. 19:41:08.943 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:09.027 DRIVER The awake timeout for node 16 has elapsed. Assuming it is asleep. 19:41:09.028 CNTRLR [Node 016] The node is now asleep. 19:41:09.040 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:09.286 DRIVER The awake timeout for node 17 has elapsed. Assuming it is asleep. 19:41:09.288 CNTRLR [Node 017] The node is now asleep. 19:41:09.305 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:09.415 DRIVER The awake timeout for node 18 has elapsed. Assuming it is asleep. 19:41:09.416 CNTRLR [Node 018] The node is now asleep. 19:41:09.427 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:09.700 DRIVER The awake timeout for node 20 has elapsed. Assuming it is asleep. 19:41:09.702 CNTRLR [Node 020] The node is now asleep. 19:41:09.719 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:10.766 SERIAL « 0x0106004981000031 (8 bytes) 19:41:10.771 DRIVER « [REQ] [ApplicationUpdateRequest] [fatal_node] payload: 0x810000 19:41:10.775 CNTRLR [Node 032] The node did not respond to the current transaction, scheduling att empt (3/3) in 500 ms... 19:41:10.767 SERIAL Buffer := 0x0106004981000031 (8 bytes) 19:41:10.769 SERIAL » [ACK] (0x06) 19:41:10.777 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:11.276 DRIVER » [Node 032] [REQ] [RequestNodeInfo] [attempt 3/3] payload: 0x20 19:41:11.277 SERIAL » 0x0104006020bb (6 bytes) 19:41:11.282 SERIAL « [ACK] (0x06) 19:41:11.283 DRIVER ACK received from controller for current transaction 19:41:11.284 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:11.291 SERIAL « 0x01040160019b (6 bytes) 19:41:11.295 DRIVER « [RES] [RequestNodeInfo] [confirmation] payload: 0x01 19:41:11.292 SERIAL Buffer := 0x01040160019b (6 bytes) 19:41:11.293 SERIAL » [ACK] (0x06) 19:41:11.297 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:11.371 DRIVER The awake timeout for node 23 has elapsed. Assuming it is asleep. 19:41:11.373 CNTRLR [Node 023] The node is now asleep. 19:41:11.384 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:11.483 DRIVER The awake timeout for node 24 has elapsed. Assuming it is asleep. 19:41:11.484 CNTRLR [Node 024] The node is now asleep. 19:41:11.496 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:11.613 DRIVER The awake timeout for node 30 has elapsed. Assuming it is asleep. 19:41:11.614 CNTRLR [Node 030] The node is now asleep. 19:41:11.632 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:11.701 DRIVER The awake timeout for node 31 has elapsed. Assuming it is asleep. 19:41:11.703 CNTRLR [Node 031] The node is now asleep. 19:41:11.713 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:15.533 SERIAL « 0x0106004981000031 (8 bytes) 19:41:15.540 DRIVER « [REQ] [ApplicationUpdateRequest] [fatal_node] payload: 0x810000 19:41:15.549 CNTRLR node interview failed: Error: The transaction timed out 19:41:15.536 SERIAL Buffer := 0x0106004981000031 (8 bytes) 19:41:15.538 SERIAL » [ACK] (0x06) 19:41:15.547 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:15.556 SERIAL » 0x01040041219b (6 bytes) 19:41:15.545 DRIVER resuming send queue 19:41:15.554 DRIVER » [Node 033] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x21 19:41:15.563 SERIAL « [ACK] (0x06) 19:41:15.566 DRIVER ACK received from controller for current transaction 19:41:15.580 CNTRLR « [Node 033] received response for protocol info: basic device class: Static Controller (0x04) generic device class: UNKNOWN (0x07) (0x07) specific device class: UNKNOWN (0x01) (0x01) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 19:41:15.567 SERIAL « 0x0601090141539c010407017a (12 bytes) 19:41:15.569 SERIAL Buffer := 0x01090141539c010407017a (11 bytes) 19:41:15.571 SERIAL » [ACK] (0x06) 19:41:15.601 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:15.611 SERIAL » 0x010400412298 (6 bytes) 19:41:15.574 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c01040701 19:41:15.575 DRIVER ACK already received, resolving transaction 19:41:15.577 DRIVER resuming send queue 19:41:15.608 DRIVER » [Node 034] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x22 19:41:15.614 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:15.583 CNTRLR [Node 033] The node is now awake. 19:41:15.692 SERIAL « [ACK] (0x06) 19:41:15.695 DRIVER ACK received from controller for current transaction 19:41:15.715 CNTRLR « [Node 034] received response for protocol info: basic device class: Static Controller (0x04) generic device class: UNKNOWN (0x07) (0x07) specific device class: UNKNOWN (0x01) (0x01) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 19:41:15.697 SERIAL « 0x0601090141539c010407017a (12 bytes) 19:41:15.700 SERIAL Buffer := 0x01090141539c010407017a (11 bytes) 19:41:15.703 SERIAL » [ACK] (0x06) 19:41:15.731 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:15.745 SERIAL » 0x010400412399 (6 bytes) 19:41:15.707 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c01040701 19:41:15.711 DRIVER ACK already received, resolving transaction 19:41:15.712 DRIVER resuming send queue 19:41:15.743 DRIVER » [Node 035] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x23 19:41:15.750 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:15.759 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:15.718 CNTRLR [Node 034] The node is now awake. 19:41:15.733 CNTRLR [Node 034] Interview stage completed: ProtocolInfo 19:41:15.735 CNTRLR » [Node 034] querying node info... 19:41:15.781 CNTRLR [Node 033] Interview stage completed: ProtocolInfo 19:41:15.800 CNTRLR » [Node 033] querying node info... 19:41:15.807 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:15.810 SERIAL « [ACK] (0x06) 19:41:15.828 CNTRLR « [Node 035] received response for protocol info: basic device class: Static Controller (0x04) generic device class: UNKNOWN (0x07) (0x07) specific device class: UNKNOWN (0x01) (0x01) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 19:41:15.812 DRIVER ACK received from controller for current transaction 19:41:15.822 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c01040701 19:41:15.824 DRIVER ACK already received, resolving transaction 19:41:15.825 DRIVER resuming send queue 19:41:15.814 SERIAL « 0x0601090141539c010407017a (12 bytes) 19:41:15.816 SERIAL Buffer := 0x01090141539c010407017a (11 bytes) 19:41:15.820 SERIAL » [ACK] (0x06) 19:41:15.847 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:15.864 SERIAL » 0x01040041249e (6 bytes) 19:41:15.830 CNTRLR [Node 035] The node is now awake. 19:41:15.849 CNTRLR [Node 035] Interview stage completed: ProtocolInfo 19:41:15.851 CNTRLR » [Node 035] querying node info... 19:41:15.862 DRIVER » [Node 036] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x24 19:41:15.866 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:15.868 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:15.888 SERIAL « [ACK] (0x06) 19:41:15.890 DRIVER ACK received from controller for current transaction 19:41:15.905 CNTRLR « [Node 036] received response for protocol info: basic device class: Static Controller (0x04) generic device class: UNKNOWN (0x07) (0x07) specific device class: UNKNOWN (0x01) (0x01) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 19:41:15.892 SERIAL « 0x0601090141539c010407017a (12 bytes) 19:41:15.893 SERIAL Buffer := 0x01090141539c010407017a (11 bytes) 19:41:15.896 SERIAL » [ACK] (0x06) 19:41:15.985 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:15.992 SERIAL » 0x01040041259f (6 bytes) 19:41:15.899 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c01040701 19:41:15.902 DRIVER ACK already received, resolving transaction 19:41:15.903 DRIVER resuming send queue 19:41:15.990 DRIVER » [Node 037] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x25 19:41:15.995 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:15.907 CNTRLR [Node 036] The node is now awake. 19:41:16.100 SERIAL « [ACK] (0x06) 19:41:16.102 DRIVER ACK received from controller for current transaction 19:41:16.113 CNTRLR « [Node 037] received response for protocol info: basic device class: Static Controller (0x04) generic device class: UNKNOWN (0x07) (0x07) specific device class: UNKNOWN (0x01) (0x01) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 19:41:16.105 SERIAL « 0x0601090141539c010407017a (12 bytes) 19:41:16.106 SERIAL Buffer := 0x01090141539c010407017a (11 bytes) 19:41:16.108 SERIAL » [ACK] (0x06) 19:41:16.123 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.132 SERIAL » 0x01040041269c (6 bytes) 19:41:16.110 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c01040701 19:41:16.111 DRIVER ACK already received, resolving transaction 19:41:16.112 DRIVER resuming send queue 19:41:16.130 DRIVER » [Node 038] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x26 19:41:16.133 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:16.134 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:16.115 CNTRLR [Node 037] The node is now awake. 19:41:16.124 CNTRLR [Node 037] Interview stage completed: ProtocolInfo 19:41:16.126 CNTRLR » [Node 037] querying node info... 19:41:16.147 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:16.137 CNTRLR [Node 036] Interview stage completed: ProtocolInfo 19:41:16.139 CNTRLR » [Node 036] querying node info... 19:41:16.156 SERIAL « [ACK] (0x06) 19:41:16.161 DRIVER ACK received from controller for current transaction 19:41:16.170 CNTRLR « [Node 038] received response for protocol info: basic device class: Static Controller (0x04) generic device class: UNKNOWN (0x07) (0x07) specific device class: UNKNOWN (0x01) (0x01) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 19:41:16.163 SERIAL « 0x0601090141539c010407017a (12 bytes) 19:41:16.164 SERIAL Buffer := 0x01090141539c010407017a (11 bytes) 19:41:16.166 SERIAL » [ACK] (0x06) 19:41:16.179 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.190 SERIAL » 0x01040041279d (6 bytes) 19:41:16.167 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c01040701 19:41:16.168 DRIVER ACK already received, resolving transaction 19:41:16.169 DRIVER resuming send queue 19:41:16.188 DRIVER » [Node 039] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x27 19:41:16.191 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:16.191 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:16.172 CNTRLR [Node 038] The node is now awake. 19:41:16.181 CNTRLR [Node 038] Interview stage completed: ProtocolInfo 19:41:16.182 CNTRLR » [Node 038] querying node info... 19:41:16.210 SERIAL « [ACK] (0x06) 19:41:16.212 DRIVER ACK received from controller for current transaction 19:41:16.226 CNTRLR « [Node 039] received response for protocol info: basic device class: Static Controller (0x04) generic device class: UNKNOWN (0x07) (0x07) specific device class: UNKNOWN (0x01) (0x01) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 19:41:16.215 SERIAL « 0x0601090141539c010407017a (12 bytes) 19:41:16.218 SERIAL Buffer := 0x01090141539c010407017a (11 bytes) 19:41:16.220 SERIAL » [ACK] (0x06) 19:41:16.237 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.245 SERIAL » 0x010400412993 (6 bytes) 19:41:16.222 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c01040701 19:41:16.223 DRIVER ACK already received, resolving transaction 19:41:16.224 DRIVER resuming send queue 19:41:16.244 DRIVER » [Node 041] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x29 19:41:16.248 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:16.250 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:16.228 CNTRLR [Node 039] The node is now awake. 19:41:16.238 CNTRLR [Node 039] Interview stage completed: ProtocolInfo 19:41:16.240 CNTRLR » [Node 039] querying node info... 19:41:16.264 SERIAL « [ACK] (0x06) 19:41:16.277 DRIVER ACK received from controller for current transaction 19:41:16.287 CNTRLR « [Node 041] received response for protocol info: basic device class: Static Controller (0x04) generic device class: UNKNOWN (0x07) (0x07) specific device class: UNKNOWN (0x01) (0x01) is a listening device: false is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: false maximum baud rate: 40000 kbps version: 4 19:41:16.279 SERIAL « 0x0601090141539c010407017a (12 bytes) 19:41:16.280 SERIAL Buffer := 0x01090141539c010407017a (11 bytes) 19:41:16.281 SERIAL » [ACK] (0x06) 19:41:16.299 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.303 SERIAL » 0x01040041308a (6 bytes) 19:41:16.283 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0x539c01040701 19:41:16.284 DRIVER ACK already received, resolving transaction 19:41:16.285 DRIVER resuming send queue 19:41:16.302 DRIVER » [Node 048] [REQ] [GetNodeProtocolInfo] [P: Controller] payload: 0x30 19:41:16.304 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:16.289 CNTRLR [Node 041] The node is now awake. 19:41:16.367 SERIAL « [ACK] (0x06) 19:41:16.369 DRIVER ACK received from controller for current transaction 19:41:16.378 CNTRLR « [Node 048] received response for protocol info: basic device class: Static Controller (0x04) generic device class: Multilevel Switch (0x11) specific device class: Motor Control Class B (0x06) is a listening device: true is frequent listening: false is a routing device: true is a secure device: false is a beaming device: true is a listening device: true maximum baud rate: 40000 kbps version: 4 19:41:16.371 SERIAL « 0x0601090141d39c01041106eb (12 bytes) 19:41:16.372 SERIAL Buffer := 0x01090141d39c01041106eb (11 bytes) 19:41:16.373 SERIAL » [ACK] (0x06) 19:41:16.380 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.389 SERIAL » 0x010900130e028611250d56 (11 bytes) 19:41:16.375 DRIVER « [RES] [GetNodeProtocolInfo] [final] payload: 0xd39c01041106 19:41:16.376 DRIVER ACK already received, resolving transaction 19:41:16.376 DRIVER resuming send queue 19:41:16.388 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 13 └─[VersionCCGet] 19:41:16.391 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:16.380 CNTRLR [Node 048] Interview stage completed: ProtocolInfo 19:41:16.381 CNTRLR » [Node 048] querying node info... 19:41:16.398 CNTRLR [Node 041] Interview stage completed: ProtocolInfo 19:41:16.399 CNTRLR » [Node 041] querying node info... 19:41:16.402 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:16.404 SERIAL « [ACK] (0x06) 19:41:16.405 DRIVER ACK received from controller for current transaction 19:41:16.406 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.412 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:16.409 SERIAL « 0x0104011301e8 (6 bytes) 19:41:16.410 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:16.411 SERIAL » [ACK] (0x06) 19:41:16.414 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.419 SERIAL « 0x010700130d000002e4 (9 bytes) 19:41:16.424 DRIVER « [REQ] [SendData] [confirmation] callbackId: 13 transmitStatus: OK 19:41:16.421 SERIAL Buffer := 0x010700130d000002e4 (9 bytes) 19:41:16.422 SERIAL » [ACK] (0x06) 19:41:16.427 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.425 DRIVER ACK received from node for current transaction. RTT = 37.50 ms 19:41:16.431 SERIAL « 0x010d0004000e07861203033419195f (15 bytes) 19:41:16.435 CNTRLR [Node 014] [+] [Version] libraryType: 3 [Endpoint 0] 19:41:16.452 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[VersionCCReport] payload: 0x0303341919 19:41:16.432 SERIAL Buffer := 0x010d0004000e07861203033419195f (15 bytes) 19:41:16.450 SERIAL » [ACK] (0x06) 19:41:16.457 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.471 SERIAL » 0x010a00131303700501250ea9 (12 bytes) 19:41:16.441 CNTRLR [Node 014] [+] [Version] protocolVersion: "3.52" [Endpoint 0] 19:41:16.446 CNTRLR [Node 014] [+] [Version] firmwareVersions: 25.25 [Endpoint 0] 19:41:16.459 CNTRLR « [Node 014] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 3.52 firmware versions: 25.25 19:41:16.461 CNTRLR » [Node 014] querying CC versions... 19:41:16.463 CNTRLR » [Node 014] querying the CC version for Manufacturer Specific (0x72)... 19:41:16.454 DRIVER ACK already received, resolving transaction 19:41:16.455 DRIVER resuming send queue 19:41:16.470 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 14 └─[ConfigurationCCGet] payload: 0x01 19:41:16.473 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:16.480 SERIAL « [ACK] (0x06) 19:41:16.482 DRIVER ACK received from controller for current transaction 19:41:16.483 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.493 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:16.487 SERIAL « 0x0104011301e8 (6 bytes) 19:41:16.488 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:16.491 SERIAL » [ACK] (0x06) 19:41:16.497 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.520 SERIAL « 0x010700130e000002e7 (9 bytes) 19:41:16.532 DRIVER « [REQ] [SendData] [confirmation] callbackId: 14 transmitStatus: OK 19:41:16.523 SERIAL Buffer := 0x010700130e000002e7 (9 bytes) 19:41:16.527 SERIAL » [ACK] (0x06) 19:41:16.539 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.536 DRIVER ACK received from node for current transaction. RTT = 68.42 ms 19:41:16.575 CNTRLR [Node 019] [+] [Configuration] 1: 1 19:41:16.546 SERIAL « 0x010b0004001305700601010191 (13 bytes) 19:41:16.548 SERIAL Buffer := 0x010b0004001305700601010191 (13 bytes) 19:41:16.586 SERIAL » [ACK] (0x06) 19:41:16.596 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.612 SERIAL » 0x0109001315028611250f4f (11 bytes) 19:41:16.589 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x010101 19:41:16.592 DRIVER ACK already received, resolving transaction 19:41:16.594 DRIVER resuming send queue 19:41:16.610 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 15 └─[VersionCCGet] 19:41:16.614 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:16.601 CNTRLR » [Node 019] querying parameter #16 value... 19:41:16.627 SERIAL « [ACK] (0x06) 19:41:16.629 DRIVER ACK received from controller for current transaction 19:41:16.630 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.648 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:16.640 SERIAL « 0x0104011301e8 (6 bytes) 19:41:16.643 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:16.645 SERIAL » [ACK] (0x06) 19:41:16.651 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.671 DRIVER « [REQ] [SendData] [confirmation] callbackId: 15 transmitStatus: OK 19:41:16.665 SERIAL « 0x010700130f000003e7 (9 bytes) 19:41:16.667 SERIAL Buffer := 0x010700130f000003e7 (9 bytes) 19:41:16.669 SERIAL » [ACK] (0x06) 19:41:16.676 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.674 DRIVER ACK received from node for current transaction. RTT = 64.26 ms 19:41:16.697 CNTRLR [Node 021] [+] [Version] libraryType: 3 [Endpoint 0] 19:41:16.690 SERIAL « 0x010f00040015098612030405010101007f (17 bytes) 19:41:16.691 SERIAL Buffer := 0x010f00040015098612030405010101007f (17 bytes) 19:41:16.716 SERIAL » [ACK] (0x06) 19:41:16.724 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.718 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[VersionCCReport] payload: 0x03040501010100 19:41:16.720 DRIVER ACK already received, resolving transaction 19:41:16.722 DRIVER resuming send queue 19:41:16.744 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 16 └─[VersionCCCommandClassGet] payload: 0x72 19:41:16.747 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:16.704 CNTRLR [Node 021] [+] [Version] protocolVersion: "4.5" [Endpoint 0] 19:41:16.711 CNTRLR [Node 021] [+] [Version] firmwareVersions: 1.1 [Endpoint 0] 19:41:16.725 CNTRLR « [Node 021] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 4.5 firmware versions: 1.1 19:41:16.727 CNTRLR » [Node 021] querying CC versions... 19:41:16.730 CNTRLR » [Node 021] querying the CC version for Z-Wave Plus Info (0x5e)... 19:41:16.745 SERIAL » 0x010a00130e03861372251039 (12 bytes) 19:41:16.757 SERIAL « [ACK] (0x06) 19:41:16.759 DRIVER ACK received from controller for current transaction 19:41:16.762 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.772 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:16.765 SERIAL « 0x0104011301e8 (6 bytes) 19:41:16.767 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:16.770 SERIAL » [ACK] (0x06) 19:41:16.775 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.784 DRIVER « [REQ] [SendData] [confirmation] callbackId: 16 transmitStatus: OK 19:41:16.779 SERIAL « 0x0107001310000003f8 (9 bytes) 19:41:16.780 SERIAL Buffer := 0x0107001310000003f8 (9 bytes) 19:41:16.782 SERIAL » [ACK] (0x06) 19:41:16.798 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.795 DRIVER ACK received from node for current transaction. RTT = 52.81 ms 19:41:16.813 CNTRLR [Node 014] supports CC Manufacturer Specific (0x72) in version 1 19:41:16.801 SERIAL « 0x010a0004000e04861472011a (12 bytes) 19:41:16.802 SERIAL Buffer := 0x010a0004000e04861472011a (12 bytes) 19:41:16.805 SERIAL » [ACK] (0x06) 19:41:16.812 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.834 SERIAL » 0x010a001313037005102511a7 (12 bytes) 19:41:16.807 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x7201 19:41:16.808 DRIVER ACK already received, resolving transaction 19:41:16.809 DRIVER resuming send queue 19:41:16.832 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 17 └─[ConfigurationCCGet] payload: 0x10 19:41:16.836 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:16.816 CNTRLR » [Node 014] querying the CC version for Version (0x86)... 19:41:16.849 SERIAL « [ACK] (0x06) 19:41:16.851 DRIVER ACK received from controller for current transaction 19:41:16.853 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.866 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:16.857 SERIAL « 0x0104011301e8 (6 bytes) 19:41:16.860 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:16.862 SERIAL » [ACK] (0x06) 19:41:16.872 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.893 SERIAL « 0x0107001311000003f9 (9 bytes) 19:41:16.900 DRIVER « [REQ] [SendData] [confirmation] callbackId: 17 transmitStatus: OK 19:41:16.895 SERIAL Buffer := 0x0107001311000003f9 (9 bytes) 19:41:16.897 SERIAL » [ACK] (0x06) 19:41:16.906 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.904 DRIVER ACK received from node for current transaction. RTT = 71.68 ms 19:41:16.934 CNTRLR [Node 019] [+] [Configuration] 16: 1 19:41:16.920 SERIAL « 0x010b0004001305700610010180 (13 bytes) 19:41:16.922 SERIAL Buffer := 0x010b0004001305700610010180 (13 bytes) 19:41:16.941 SERIAL » [ACK] (0x06) 19:41:16.951 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:16.975 SERIAL » 0x010a0013150386135e25120c (12 bytes) 19:41:16.944 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x100101 19:41:16.947 DRIVER ACK already received, resolving transaction 19:41:16.948 DRIVER resuming send queue 19:41:16.973 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 18 └─[VersionCCCommandClassGet] payload: 0x5e 19:41:16.978 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:16.953 CNTRLR » [Node 019] querying parameter #34 value... 19:41:17.003 SERIAL « [ACK] (0x06) 19:41:17.005 DRIVER ACK received from controller for current transaction 19:41:17.007 SERIAL « 0x060104011301e8 (7 bytes) 19:41:17.009 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:17.013 SERIAL » [ACK] (0x06) 19:41:17.019 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.016 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:17.032 SERIAL « 0x0107001312000003fa (9 bytes) 19:41:17.039 DRIVER « [REQ] [SendData] [confirmation] callbackId: 18 transmitStatus: OK 19:41:17.034 SERIAL Buffer := 0x0107001312000003fa (9 bytes) 19:41:17.036 SERIAL » [ACK] (0x06) 19:41:17.044 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.041 DRIVER ACK received from node for current transaction. RTT = 68.62 ms 19:41:17.064 CNTRLR [Node 021] supports CC Z-Wave Plus Info (0x5e) in version 2 19:41:17.047 SERIAL « 0x010a000400150486145e022e (12 bytes) 19:41:17.049 SERIAL Buffer := 0x010a000400150486145e022e (12 bytes) 19:41:17.053 SERIAL » [ACK] (0x06) 19:41:17.062 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.079 SERIAL » 0x010a00130e038613862513ce (12 bytes) 19:41:17.056 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x5e02 19:41:17.058 DRIVER ACK already received, resolving transaction 19:41:17.060 DRIVER resuming send queue 19:41:17.077 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 19 └─[VersionCCCommandClassGet] payload: 0x86 19:41:17.081 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:17.067 CNTRLR » [Node 021] querying the CC version for Version (0x86)... 19:41:17.101 SERIAL « [ACK] (0x06) 19:41:17.104 DRIVER ACK received from controller for current transaction 19:41:17.105 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.119 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:17.115 SERIAL « 0x0104011301e8 (6 bytes) 19:41:17.116 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:17.117 SERIAL » [ACK] (0x06) 19:41:17.121 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.126 SERIAL « 0x0107001313000002fa (9 bytes) 19:41:17.141 DRIVER « [REQ] [SendData] [confirmation] callbackId: 19 transmitStatus: OK 19:41:17.127 SERIAL Buffer := 0x0107001313000002fa (9 bytes) 19:41:17.138 SERIAL » [ACK] (0x06) 19:41:17.144 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.142 DRIVER ACK received from node for current transaction. RTT = 66.83 ms 19:41:17.159 CNTRLR [Node 014] supports CC Version (0x86) in version 1 19:41:17.147 SERIAL « 0x010a0004000e0486148601ee (12 bytes) 19:41:17.149 SERIAL Buffer := 0x010a0004000e0486148601ee (12 bytes) 19:41:17.151 SERIAL » [ACK] (0x06) 19:41:17.157 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.168 SERIAL » 0x010a00131303700522251490 (12 bytes) 19:41:17.153 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8601 19:41:17.154 DRIVER ACK already received, resolving transaction 19:41:17.156 DRIVER resuming send queue 19:41:17.166 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 20 └─[ConfigurationCCGet] payload: 0x22 19:41:17.170 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:17.161 CNTRLR » [Node 014] querying the CC version for Configuration (0x70)... 19:41:17.177 SERIAL « [ACK] (0x06) 19:41:17.179 DRIVER ACK received from controller for current transaction 19:41:17.181 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.189 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:17.185 SERIAL « 0x0104011301e8 (6 bytes) 19:41:17.186 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:17.187 SERIAL » [ACK] (0x06) 19:41:17.200 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.212 DRIVER « [REQ] [SendData] [confirmation] callbackId: 20 transmitStatus: OK 19:41:17.207 SERIAL « 0x0107001314000003fc (9 bytes) 19:41:17.208 SERIAL Buffer := 0x0107001314000003fc (9 bytes) 19:41:17.210 SERIAL » [ACK] (0x06) 19:41:17.216 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.214 DRIVER ACK received from node for current transaction. RTT = 48.68 ms 19:41:17.232 CNTRLR [Node 019] [+] [Configuration] 34: 63 19:41:17.219 SERIAL « 0x010b0004001305700622013f8c (13 bytes) 19:41:17.221 SERIAL Buffer := 0x010b0004001305700622013f8c (13 bytes) 19:41:17.238 SERIAL » [ACK] (0x06) 19:41:17.245 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.254 SERIAL » 0x010a001315038613862515d3 (12 bytes) 19:41:17.241 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x22013f 19:41:17.243 DRIVER ACK already received, resolving transaction 19:41:17.244 DRIVER resuming send queue 19:41:17.252 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 21 └─[VersionCCCommandClassGet] payload: 0x86 19:41:17.255 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:17.247 CNTRLR » [Node 019] querying parameter #35 value... 19:41:17.262 SERIAL « [ACK] (0x06) 19:41:17.264 DRIVER ACK received from controller for current transaction 19:41:17.267 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.275 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:17.271 SERIAL « 0x0104011301e8 (6 bytes) 19:41:17.272 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:17.274 SERIAL » [ACK] (0x06) 19:41:17.277 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.291 SERIAL « 0x0107001315000003fd (9 bytes) 19:41:17.298 DRIVER « [REQ] [SendData] [confirmation] callbackId: 21 transmitStatus: OK 19:41:17.293 SERIAL Buffer := 0x0107001315000003fd (9 bytes) 19:41:17.295 SERIAL » [ACK] (0x06) 19:41:17.303 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.301 DRIVER ACK received from node for current transaction. RTT = 49.04 ms 19:41:17.314 SERIAL « 0x010a000400150486148602f6 (12 bytes) 19:41:17.319 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8602 19:41:17.324 CNTRLR [Node 021] supports CC Version (0x86) in version 2 19:41:17.315 SERIAL Buffer := 0x010a000400150486148602f6 (12 bytes) 19:41:17.317 SERIAL » [ACK] (0x06) 19:41:17.323 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.341 SERIAL » 0x010a00130e0386137025163d (12 bytes) 19:41:17.321 DRIVER ACK already received, resolving transaction 19:41:17.322 DRIVER resuming send queue 19:41:17.339 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 22 └─[VersionCCCommandClassGet] payload: 0x70 19:41:17.343 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:17.333 CNTRLR » [Node 021] querying the CC version for Manufacturer Specific (0x72)... 19:41:17.348 SERIAL « [ACK] (0x06) 19:41:17.350 DRIVER ACK received from controller for current transaction 19:41:17.351 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.354 SERIAL « 0x0104011301e8 (6 bytes) 19:41:17.359 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:17.356 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:17.357 SERIAL » [ACK] (0x06) 19:41:17.361 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.375 SERIAL « 0x0107001316000002ff (9 bytes) 19:41:17.380 DRIVER « [REQ] [SendData] [confirmation] callbackId: 22 transmitStatus: OK 19:41:17.376 SERIAL Buffer := 0x0107001316000002ff (9 bytes) 19:41:17.378 SERIAL » [ACK] (0x06) 19:41:17.383 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.381 DRIVER ACK received from node for current transaction. RTT = 43.50 ms 19:41:17.396 CNTRLR [Node 014] supports CC Configuration (0x70) in version 1 19:41:17.386 SERIAL « 0x010a0004000e048614700118 (12 bytes) 19:41:17.387 SERIAL Buffer := 0x010a0004000e048614700118 (12 bytes) 19:41:17.390 SERIAL » [ACK] (0x06) 19:41:17.395 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.391 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x7001 19:41:17.393 DRIVER ACK already received, resolving transaction 19:41:17.394 DRIVER resuming send queue 19:41:17.398 CNTRLR » [Node 014] querying the CC version for Association (0x85)... 19:41:17.404 SERIAL » 0x010a00131303700523251792 (12 bytes) 19:41:17.403 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 23 └─[ConfigurationCCGet] payload: 0x23 19:41:17.406 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:17.410 SERIAL « [ACK] (0x06) 19:41:17.412 DRIVER ACK received from controller for current transaction 19:41:17.413 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.417 SERIAL « 0x0104011301e8 (6 bytes) 19:41:17.422 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:17.419 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:17.420 SERIAL » [ACK] (0x06) 19:41:17.424 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.434 SERIAL « 0x0107001317000002fe (9 bytes) 19:41:17.439 DRIVER « [REQ] [SendData] [confirmation] callbackId: 23 transmitStatus: OK 19:41:17.436 SERIAL Buffer := 0x0107001317000002fe (9 bytes) 19:41:17.437 SERIAL » [ACK] (0x06) 19:41:17.443 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.441 DRIVER ACK received from node for current transaction. RTT = 38.76 ms 19:41:17.452 CNTRLR [Node 019] [+] [Configuration] 35: 0 19:41:17.446 SERIAL « 0x010b00040013057006230100b2 (13 bytes) 19:41:17.447 SERIAL Buffer := 0x010b00040013057006230100b2 (13 bytes) 19:41:17.457 SERIAL » [ACK] (0x06) 19:41:17.464 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.472 SERIAL » 0x010a0013150386137225182a (12 bytes) 19:41:17.460 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x230100 19:41:17.461 DRIVER ACK already received, resolving transaction 19:41:17.462 DRIVER resuming send queue 19:41:17.471 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 24 └─[VersionCCCommandClassGet] payload: 0x72 19:41:17.474 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:17.465 CNTRLR » [Node 019] querying parameter #39 value... 19:41:17.482 SERIAL « [ACK] (0x06) 19:41:17.484 DRIVER ACK received from controller for current transaction 19:41:17.486 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.495 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:17.491 SERIAL « 0x0104011301e8 (6 bytes) 19:41:17.492 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:17.494 SERIAL » [ACK] (0x06) 19:41:17.497 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.509 SERIAL « 0x0107001318000003f0 (9 bytes) 19:41:17.516 DRIVER « [REQ] [SendData] [confirmation] callbackId: 24 transmitStatus: OK 19:41:17.511 SERIAL Buffer := 0x0107001318000003f0 (9 bytes) 19:41:17.514 SERIAL » [ACK] (0x06) 19:41:17.520 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.518 DRIVER ACK received from node for current transaction. RTT = 48.09 ms 19:41:17.532 CNTRLR [Node 021] supports CC Manufacturer Specific (0x72) in version 2 19:41:17.523 SERIAL « 0x010a00040015048614720202 (12 bytes) 19:41:17.524 SERIAL Buffer := 0x010a00040015048614720202 (12 bytes) 19:41:17.526 SERIAL » [ACK] (0x06) 19:41:17.531 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.546 SERIAL » 0x010a00130e038613852519c7 (12 bytes) 19:41:17.528 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x7202 19:41:17.529 DRIVER ACK already received, resolving transaction 19:41:17.530 DRIVER resuming send queue 19:41:17.544 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 25 └─[VersionCCCommandClassGet] payload: 0x85 19:41:17.547 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:17.534 CNTRLR [Node 021] skipping query for Device Reset Locally (0x5a) because max implem ented version is 1 19:41:17.535 CNTRLR [Node 021] skipping query for Powerlevel (0x73) because max implemented vers ion is 0 19:41:17.537 CNTRLR » [Node 021] querying the CC version for Basic (0x20)... 19:41:17.554 SERIAL « [ACK] (0x06) 19:41:17.555 DRIVER ACK received from controller for current transaction 19:41:17.556 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.567 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:17.559 SERIAL « 0x0104011301e8 (6 bytes) 19:41:17.560 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:17.565 SERIAL » [ACK] (0x06) 19:41:17.569 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.576 SERIAL « 0x0107001319000002f0 (9 bytes) 19:41:17.581 DRIVER « [REQ] [SendData] [confirmation] callbackId: 25 transmitStatus: OK 19:41:17.578 SERIAL Buffer := 0x0107001319000002f0 (9 bytes) 19:41:17.579 SERIAL » [ACK] (0x06) 19:41:17.584 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.582 DRIVER ACK received from node for current transaction. RTT = 39.16 ms 19:41:17.597 CNTRLR [Node 014] supports CC Association (0x85) in version 2 19:41:17.587 SERIAL « 0x010a0004000e0486148502ee (12 bytes) 19:41:17.588 SERIAL Buffer := 0x010a0004000e0486148502ee (12 bytes) 19:41:17.590 SERIAL » [ACK] (0x06) 19:41:17.595 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.604 SERIAL » 0x010a00131303700527251a9b (12 bytes) 19:41:17.592 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8502 19:41:17.593 DRIVER ACK already received, resolving transaction 19:41:17.594 DRIVER resuming send queue 19:41:17.603 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 26 └─[ConfigurationCCGet] payload: 0x27 19:41:17.606 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:17.598 CNTRLR » [Node 014] querying the CC version for Multi Channel Association (0x8e)... 19:41:17.612 SERIAL « [ACK] (0x06) 19:41:17.614 DRIVER ACK received from controller for current transaction 19:41:17.616 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.624 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:17.619 SERIAL « 0x0104011301e8 (6 bytes) 19:41:17.620 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:17.622 SERIAL » [ACK] (0x06) 19:41:17.626 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.639 SERIAL « 0x010700131a000002f3 (9 bytes) 19:41:17.644 DRIVER « [REQ] [SendData] [confirmation] callbackId: 26 transmitStatus: OK 19:41:17.640 SERIAL Buffer := 0x010700131a000002f3 (9 bytes) 19:41:17.642 SERIAL » [ACK] (0x06) 19:41:17.648 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.646 DRIVER ACK received from node for current transaction. RTT = 43.90 ms 19:41:17.662 CNTRLR [Node 019] [+] [Configuration] 39: 600 19:41:17.655 SERIAL « 0x010c0004001306700627020258eb (14 bytes) 19:41:17.656 SERIAL Buffer := 0x010c0004001306700627020258eb (14 bytes) 19:41:17.668 SERIAL » [ACK] (0x06) 19:41:17.679 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.690 SERIAL » 0x010a00131503861320251b7b (12 bytes) 19:41:17.671 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x27020258 19:41:17.674 DRIVER ACK already received, resolving transaction 19:41:17.676 DRIVER resuming send queue 19:41:17.688 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 27 └─[VersionCCCommandClassGet] payload: 0x20 19:41:17.692 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:17.681 CNTRLR » [Node 019] querying parameter #40 value... 19:41:17.702 SERIAL « [ACK] (0x06) 19:41:17.704 DRIVER ACK received from controller for current transaction 19:41:17.706 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.735 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:17.720 SERIAL « 0x0104011301e8 (6 bytes) 19:41:17.721 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:17.732 SERIAL » [ACK] (0x06) 19:41:17.736 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.744 DRIVER « [REQ] [SendData] [confirmation] callbackId: 27 transmitStatus: OK 19:41:17.739 SERIAL « 0x010700131b000002f2 (9 bytes) 19:41:17.741 SERIAL Buffer := 0x010700131b000002f2 (9 bytes) 19:41:17.742 SERIAL » [ACK] (0x06) 19:41:17.747 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.746 DRIVER ACK received from node for current transaction. RTT = 59.11 ms 19:41:17.767 CNTRLR [Node 021] supports CC Basic (0x20) in version 1 19:41:17.753 SERIAL « 0x010a00040015048614200153 (12 bytes) 19:41:17.754 SERIAL Buffer := 0x010a00040015048614200153 (12 bytes) 19:41:17.758 SERIAL » [ACK] (0x06) 19:41:17.766 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.782 SERIAL » 0x010a00130e0386138e251cc9 (12 bytes) 19:41:17.761 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x2001 19:41:17.763 DRIVER ACK already received, resolving transaction 19:41:17.764 DRIVER resuming send queue 19:41:17.776 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 28 └─[VersionCCCommandClassGet] payload: 0x8e 19:41:17.784 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:17.769 CNTRLR [Node 021] skipping query for All Switch (0x27) because max implemented vers ion is 0 19:41:17.770 CNTRLR » [Node 021] querying the CC version for Binary Switch (0x25)... 19:41:17.793 SERIAL « [ACK] (0x06) 19:41:17.794 DRIVER ACK received from controller for current transaction 19:41:17.796 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.803 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:17.798 SERIAL « 0x0104011301e8 (6 bytes) 19:41:17.800 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:17.801 SERIAL » [ACK] (0x06) 19:41:17.804 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.823 DRIVER « [REQ] [SendData] [confirmation] callbackId: 28 transmitStatus: OK 19:41:17.819 SERIAL « 0x010700131c000002f5 (9 bytes) 19:41:17.820 SERIAL Buffer := 0x010700131c000002f5 (9 bytes) 19:41:17.821 SERIAL » [ACK] (0x06) 19:41:17.826 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.824 DRIVER ACK received from node for current transaction. RTT = 48.89 ms 19:41:17.839 CNTRLR [Node 014] supports CC Multi Channel Association (0x8e) in version 2 19:41:17.829 SERIAL « 0x010a0004000e0486148e02e5 (12 bytes) 19:41:17.830 SERIAL Buffer := 0x010a0004000e0486148e02e5 (12 bytes) 19:41:17.832 SERIAL » [ACK] (0x06) 19:41:17.837 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.847 SERIAL » 0x010a00131303700528251d93 (12 bytes) 19:41:17.833 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8e02 19:41:17.835 DRIVER ACK already received, resolving transaction 19:41:17.836 DRIVER resuming send queue 19:41:17.846 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 29 └─[ConfigurationCCGet] payload: 0x28 19:41:17.849 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:17.841 CNTRLR » [Node 014] querying the CC version for Binary Switch (0x25)... 19:41:17.856 SERIAL « [ACK] (0x06) 19:41:17.858 DRIVER ACK received from controller for current transaction 19:41:17.859 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.869 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:17.865 SERIAL « 0x0104011301e8 (6 bytes) 19:41:17.866 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:17.868 SERIAL » [ACK] (0x06) 19:41:17.871 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.878 SERIAL « 0x010700131d000003f5 (9 bytes) 19:41:17.883 DRIVER « [REQ] [SendData] [confirmation] callbackId: 29 transmitStatus: OK 19:41:17.880 SERIAL Buffer := 0x010700131d000003f5 (9 bytes) 19:41:17.881 SERIAL » [ACK] (0x06) 19:41:17.887 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.885 DRIVER ACK received from node for current transaction. RTT = 39.62 ms 19:41:17.896 CNTRLR [Node 019] [+] [Configuration] 40: 80 19:41:17.890 SERIAL « 0x010b00040013057006280150e9 (13 bytes) 19:41:17.891 SERIAL Buffer := 0x010b00040013057006280150e9 (13 bytes) 19:41:17.901 SERIAL » [ACK] (0x06) 19:41:17.908 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.917 SERIAL » 0x010a00131503861325251e7b (12 bytes) 19:41:17.904 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x280150 19:41:17.906 DRIVER ACK already received, resolving transaction 19:41:17.907 DRIVER resuming send queue 19:41:17.914 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 30 └─[VersionCCCommandClassGet] payload: 0x25 19:41:17.919 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:17.910 CNTRLR » [Node 019] querying parameter #42 value... 19:41:17.927 SERIAL « [ACK] (0x06) 19:41:17.929 DRIVER ACK received from controller for current transaction 19:41:17.936 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.952 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:17.947 SERIAL « 0x0104011301e8 (6 bytes) 19:41:17.949 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:17.951 SERIAL » [ACK] (0x06) 19:41:17.955 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.968 DRIVER « [REQ] [SendData] [confirmation] callbackId: 30 transmitStatus: OK 19:41:17.961 SERIAL « 0x010700131e000003f6 (9 bytes) 19:41:17.964 SERIAL Buffer := 0x010700131e000003f6 (9 bytes) 19:41:17.966 SERIAL » [ACK] (0x06) 19:41:17.971 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.969 DRIVER ACK received from node for current transaction. RTT = 55.97 ms 19:41:17.989 CNTRLR [Node 021] supports CC Binary Switch (0x25) in version 1 19:41:17.977 SERIAL « 0x010a00040015048614250156 (12 bytes) 19:41:17.978 SERIAL Buffer := 0x010a00040015048614250156 (12 bytes) 19:41:17.981 SERIAL » [ACK] (0x06) 19:41:17.988 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:17.984 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x2501 19:41:17.986 DRIVER ACK already received, resolving transaction 19:41:17.987 DRIVER resuming send queue 19:41:17.996 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 31 └─[VersionCCCommandClassGet] payload: 0x25 19:41:17.999 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:17.990 CNTRLR » [Node 021] querying the CC version for Multilevel Switch (0x26)... 19:41:17.997 SERIAL » 0x010a00130e03861325251f61 (12 bytes) 19:41:18.008 SERIAL « [ACK] (0x06) 19:41:18.011 DRIVER ACK received from controller for current transaction 19:41:18.013 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.022 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:18.016 SERIAL « 0x0104011301e8 (6 bytes) 19:41:18.018 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:18.020 SERIAL » [ACK] (0x06) 19:41:18.024 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.028 SERIAL « 0x010700131f000003f7 (9 bytes) 19:41:18.033 DRIVER « [REQ] [SendData] [confirmation] callbackId: 31 transmitStatus: OK 19:41:18.029 SERIAL Buffer := 0x010700131f000003f7 (9 bytes) 19:41:18.031 SERIAL » [ACK] (0x06) 19:41:18.036 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.035 DRIVER ACK received from node for current transaction. RTT = 39.62 ms 19:41:18.047 CNTRLR [Node 014] supports CC Binary Switch (0x25) in version 1 19:41:18.039 SERIAL « 0x010a0004000e04861425014d (12 bytes) 19:41:18.040 SERIAL Buffer := 0x010a0004000e04861425014d (12 bytes) 19:41:18.042 SERIAL » [ACK] (0x06) 19:41:18.046 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.054 SERIAL » 0x010a0013130370052a2520ac (12 bytes) 19:41:18.043 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x2501 19:41:18.044 DRIVER ACK already received, resolving transaction 19:41:18.045 DRIVER resuming send queue 19:41:18.053 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 32 └─[ConfigurationCCGet] payload: 0x2a 19:41:18.055 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:18.048 CNTRLR [Node 014] skipping query for Powerlevel (0x73) because max implemented vers ion is 0 19:41:18.049 CNTRLR » [Node 014] querying the CC version for Meter (0x32)... 19:41:18.061 SERIAL « [ACK] (0x06) 19:41:18.062 DRIVER ACK received from controller for current transaction 19:41:18.064 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.071 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:18.066 SERIAL « 0x0104011301e8 (6 bytes) 19:41:18.068 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:18.069 SERIAL » [ACK] (0x06) 19:41:18.072 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.082 SERIAL « 0x0107001320000002c9 (9 bytes) 19:41:18.086 DRIVER « [REQ] [SendData] [confirmation] callbackId: 32 transmitStatus: OK 19:41:18.084 SERIAL Buffer := 0x0107001320000002c9 (9 bytes) 19:41:18.085 SERIAL » [ACK] (0x06) 19:41:18.089 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.087 DRIVER ACK received from node for current transaction. RTT = 35.06 ms 19:41:18.105 CNTRLR [Node 019] [+] [Configuration] 42: 15 19:41:18.099 SERIAL « 0x010b000400130570062a010fb4 (13 bytes) 19:41:18.101 SERIAL Buffer := 0x010b000400130570062a010fb4 (13 bytes) 19:41:18.111 SERIAL » [ACK] (0x06) 19:41:18.117 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.126 SERIAL » 0x010a00131503861326252147 (12 bytes) 19:41:18.113 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x2a010f 19:41:18.114 DRIVER ACK already received, resolving transaction 19:41:18.115 DRIVER resuming send queue 19:41:18.125 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 33 └─[VersionCCCommandClassGet] payload: 0x26 19:41:18.128 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:18.119 CNTRLR » [Node 019] querying parameter #43 value... 19:41:18.135 SERIAL « [ACK] (0x06) 19:41:18.141 DRIVER ACK received from controller for current transaction 19:41:18.142 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.148 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:18.144 SERIAL « 0x0104011301e8 (6 bytes) 19:41:18.145 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:18.146 SERIAL » [ACK] (0x06) 19:41:18.149 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.160 SERIAL « 0x0107001321000003c9 (9 bytes) 19:41:18.165 DRIVER « [REQ] [SendData] [confirmation] callbackId: 33 transmitStatus: OK 19:41:18.161 SERIAL Buffer := 0x0107001321000003c9 (9 bytes) 19:41:18.163 SERIAL » [ACK] (0x06) 19:41:18.168 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.166 DRIVER ACK received from node for current transaction. RTT = 42.54 ms 19:41:18.175 SERIAL « 0x010a00040015048614260357 (12 bytes) 19:41:18.180 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x2603 19:41:18.184 CNTRLR [Node 021] supports CC Multilevel Switch (0x26) in version 3 19:41:18.176 SERIAL Buffer := 0x010a00040015048614260357 (12 bytes) 19:41:18.178 SERIAL » [ACK] (0x06) 19:41:18.183 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.190 SERIAL » 0x010a00130e0386133225224b (12 bytes) 19:41:18.181 DRIVER ACK already received, resolving transaction 19:41:18.182 DRIVER resuming send queue 19:41:18.189 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 34 └─[VersionCCCommandClassGet] payload: 0x32 19:41:18.191 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:18.185 CNTRLR » [Node 021] querying the CC version for Meter (0x32)... 19:41:18.195 SERIAL « [ACK] (0x06) 19:41:18.196 DRIVER ACK received from controller for current transaction 19:41:18.197 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.201 SERIAL « 0x0104011301e8 (6 bytes) 19:41:18.205 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:18.203 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:18.203 SERIAL » [ACK] (0x06) 19:41:18.206 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.218 SERIAL « 0x0107001322000003ca (9 bytes) 19:41:18.222 DRIVER « [REQ] [SendData] [confirmation] callbackId: 34 transmitStatus: OK 19:41:18.219 SERIAL Buffer := 0x0107001322000003ca (9 bytes) 19:41:18.220 SERIAL » [ACK] (0x06) 19:41:18.224 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.223 DRIVER ACK received from node for current transaction. RTT = 35.16 ms 19:41:18.229 SERIAL « 0x010a0004000e048614320259 (12 bytes) 19:41:18.235 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x3202 19:41:18.240 CNTRLR [Node 014] supports CC Meter (0x32) in version 2 19:41:18.231 SERIAL Buffer := 0x010a0004000e048614320259 (12 bytes) 19:41:18.233 SERIAL » [ACK] (0x06) 19:41:18.239 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.246 SERIAL » 0x010a0013130370052b2523ae (12 bytes) 19:41:18.237 DRIVER ACK already received, resolving transaction 19:41:18.238 DRIVER resuming send queue 19:41:18.245 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 35 └─[ConfigurationCCGet] payload: 0x2b 19:41:18.251 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:18.241 CNTRLR » [Node 014] querying the CC version for Multilevel Sensor (0x31)... 19:41:18.258 SERIAL « [ACK] (0x06) 19:41:18.259 DRIVER ACK received from controller for current transaction 19:41:18.260 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.265 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:18.262 SERIAL « 0x0104011301e8 (6 bytes) 19:41:18.263 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:18.264 SERIAL » [ACK] (0x06) 19:41:18.266 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.279 SERIAL « 0x0107001323000002ca (9 bytes) 19:41:18.283 DRIVER « [REQ] [SendData] [confirmation] callbackId: 35 transmitStatus: OK 19:41:18.281 SERIAL Buffer := 0x0107001323000002ca (9 bytes) 19:41:18.282 SERIAL » [ACK] (0x06) 19:41:18.285 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.284 DRIVER ACK received from node for current transaction. RTT = 39.44 ms 19:41:18.289 SERIAL « 0x010b000400130570062b011ea4 (13 bytes) 19:41:18.294 CNTRLR [Node 019] [+] [Configuration] 43: 30 19:41:18.300 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x2b011e 19:41:18.290 SERIAL Buffer := 0x010b000400130570062b011ea4 (13 bytes) 19:41:18.298 SERIAL » [ACK] (0x06) 19:41:18.303 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.310 SERIAL » 0x010a00131503861332252456 (12 bytes) 19:41:18.304 CNTRLR » [Node 019] querying parameter #45 value... 19:41:18.301 DRIVER ACK already received, resolving transaction 19:41:18.302 DRIVER resuming send queue 19:41:18.309 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 36 └─[VersionCCCommandClassGet] payload: 0x32 19:41:18.312 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:18.318 SERIAL « [ACK] (0x06) 19:41:18.323 DRIVER ACK received from controller for current transaction 19:41:18.324 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.331 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:18.327 SERIAL « 0x0104011301e8 (6 bytes) 19:41:18.328 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:18.330 SERIAL » [ACK] (0x06) 19:41:18.332 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.344 SERIAL « 0x0107001324000002cd (9 bytes) 19:41:18.350 DRIVER « [REQ] [SendData] [confirmation] callbackId: 36 transmitStatus: OK 19:41:18.346 SERIAL Buffer := 0x0107001324000002cd (9 bytes) 19:41:18.348 SERIAL » [ACK] (0x06) 19:41:18.355 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.353 DRIVER ACK received from node for current transaction. RTT = 44.16 ms 19:41:18.362 SERIAL « 0x010a00040015048614320444 (12 bytes) 19:41:18.367 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x3204 19:41:18.371 CNTRLR [Node 021] supports CC Meter (0x32) in version 4 19:41:18.363 SERIAL Buffer := 0x010a00040015048614320444 (12 bytes) 19:41:18.365 SERIAL » [ACK] (0x06) 19:41:18.370 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.377 SERIAL » 0x010a00130e0386133125254f (12 bytes) 19:41:18.368 DRIVER ACK already received, resolving transaction 19:41:18.369 DRIVER resuming send queue 19:41:18.376 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 37 └─[VersionCCCommandClassGet] payload: 0x31 19:41:18.378 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:18.372 CNTRLR » [Node 021] querying the CC version for Association (0x85)... 19:41:18.383 SERIAL « [ACK] (0x06) 19:41:18.384 DRIVER ACK received from controller for current transaction 19:41:18.385 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.388 SERIAL « 0x0104011301e8 (6 bytes) 19:41:18.392 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:18.389 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:18.390 SERIAL » [ACK] (0x06) 19:41:18.393 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.406 SERIAL « 0x0107001325000002cc (9 bytes) 19:41:18.410 DRIVER « [REQ] [SendData] [confirmation] callbackId: 37 transmitStatus: OK 19:41:18.407 SERIAL Buffer := 0x0107001325000002cc (9 bytes) 19:41:18.408 SERIAL » [ACK] (0x06) 19:41:18.413 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.411 DRIVER ACK received from node for current transaction. RTT = 36.13 ms 19:41:18.418 SERIAL « 0x010a0004000e04861431025a (12 bytes) 19:41:18.424 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x3102 19:41:18.429 CNTRLR [Node 014] supports CC Multilevel Sensor (0x31) in version 2 19:41:18.419 SERIAL Buffer := 0x010a0004000e04861431025a (12 bytes) 19:41:18.422 SERIAL » [ACK] (0x06) 19:41:18.428 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.456 SERIAL » 0x010a0013130370052d2526ad (12 bytes) 19:41:18.426 DRIVER ACK already received, resolving transaction 19:41:18.427 DRIVER resuming send queue 19:41:18.455 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 38 └─[ConfigurationCCGet] payload: 0x2d 19:41:18.430 CNTRLR [Node 014] skipping query for Firmware Update Meta Data (0x7a) because max i mplemented version is 0 19:41:18.433 CNTRLR [Node 014] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 19:41:18.434 CNTRLR [Node 014] trying to load device config 19:41:18.472 SERIAL « [ACK] (0x06) 19:41:18.473 DRIVER ACK received from controller for current transaction 19:41:18.475 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.483 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:18.478 SERIAL « 0x0104011301e8 (6 bytes) 19:41:18.480 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:18.481 SERIAL » [ACK] (0x06) 19:41:18.513 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.540 DRIVER « [REQ] [SendData] [confirmation] callbackId: 38 transmitStatus: OK 19:41:18.610 CNTRLR [Node 014] device config loaded 19:41:18.516 SERIAL « 0x0107001326000003ce (9 bytes) 19:41:18.517 SERIAL Buffer := 0x0107001326000003ce (9 bytes) 19:41:18.538 SERIAL » [ACK] (0x06) 19:41:18.544 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.542 DRIVER ACK received from node for current transaction. RTT = 88.28 ms 19:41:18.621 CNTRLR [Node 019] [+] [Configuration] 45: 10 19:41:18.631 CNTRLR » [Node 019] querying parameter #47 value... 19:41:18.617 SERIAL « 0x010b000400130570062d010ab6 (13 bytes) 19:41:18.618 SERIAL Buffer := 0x010b000400130570062d010ab6 (13 bytes) 19:41:18.625 SERIAL » [ACK] (0x06) 19:41:18.630 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.636 SERIAL » 0x010a001315038613852527e2 (12 bytes) 19:41:18.627 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x2d010a 19:41:18.628 DRIVER ACK already received, resolving transaction 19:41:18.629 DRIVER resuming send queue 19:41:18.635 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 39 └─[VersionCCCommandClassGet] payload: 0x85 19:41:18.637 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:18.702 SERIAL « [ACK] (0x06) 19:41:18.703 DRIVER ACK received from controller for current transaction 19:41:18.704 SERIAL « 0x060104011301e8 (7 bytes) 19:41:18.705 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:18.706 SERIAL » [ACK] (0x06) 19:41:18.709 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.708 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:18.726 CNTRLR [Node 014] ConfigurationCC: Loading configuration parameters from device confi g 19:41:18.716 SERIAL « 0x0107001327000003cf (9 bytes) 19:41:18.717 SERIAL Buffer := 0x0107001327000003cf (9 bytes) 19:41:18.719 SERIAL » [ACK] (0x06) 19:41:18.722 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.720 DRIVER « [REQ] [SendData] [confirmation] callbackId: 39 transmitStatus: OK 19:41:18.721 DRIVER ACK received from node for current transaction. RTT = 86.56 ms 19:41:18.730 CNTRLR [Node 014] [+] [Configuration] isParamInformationFromConfig: false [internal] 19:41:18.732 CNTRLR [Node 014] [Configuration] 1: metadata updated 19:41:18.738 CNTRLR [Node 014] [Configuration] 16: metadata updated 19:41:18.744 CNTRLR [Node 014] [Configuration] 34: metadata updated 19:41:18.749 CNTRLR [Node 014] [Configuration] 35: metadata updated 19:41:18.755 CNTRLR [Node 014] [Configuration] 39: metadata updated 19:41:18.760 CNTRLR [Node 014] [Configuration] 40: metadata updated 19:41:18.766 CNTRLR [Node 014] [Configuration] 42: metadata updated 19:41:18.771 CNTRLR [Node 014] [Configuration] 43: metadata updated 19:41:18.777 CNTRLR [Node 014] [Configuration] 45: metadata updated 19:41:18.788 CNTRLR [Node 014] [Configuration] 47: metadata updated 19:41:18.794 CNTRLR [Node 014] [Configuration] 49: metadata updated 19:41:18.800 CNTRLR [Node 014] [Configuration] 50: metadata updated 19:41:18.805 CNTRLR [Node 014] [Configuration] 51: metadata updated 19:41:18.811 CNTRLR [Node 014] [Configuration] 52: metadata updated 19:41:18.817 CNTRLR [Node 014] [Configuration] 60: metadata updated 19:41:18.822 CNTRLR [Node 014] [Configuration] 61: metadata updated 19:41:18.828 CNTRLR [Node 014] [Configuration] 62: metadata updated 19:41:18.834 CNTRLR [Node 014] [Configuration] 63: metadata updated 19:41:18.840 CNTRLR [Node 014] [Configuration] 70: metadata updated 19:41:18.846 CNTRLR [Node 014] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 19:41:18.848 CNTRLR » [Node 014] querying parameter #1 value... 19:41:18.861 CNTRLR [Node 021] supports CC Association (0x85) in version 2 19:41:18.862 CNTRLR » [Node 021] querying the CC version for Multi Channel Association (0x8e)... 19:41:18.853 SERIAL « 0x010a000400150486148502f5 (12 bytes) 19:41:18.854 SERIAL Buffer := 0x010a000400150486148502f5 (12 bytes) 19:41:18.856 SERIAL » [ACK] (0x06) 19:41:18.860 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.869 SERIAL » 0x010a0013130370052f2528a1 (12 bytes) 19:41:18.857 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8502 19:41:18.858 DRIVER ACK already received, resolving transaction 19:41:18.859 DRIVER resuming send queue 19:41:18.868 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 40 └─[ConfigurationCCGet] payload: 0x2f 19:41:18.871 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:18.875 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:18.927 SERIAL « [ACK] (0x06) 19:41:18.929 DRIVER ACK received from controller for current transaction 19:41:18.931 SERIAL « 0x060104011301e8 (7 bytes) 19:41:18.932 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:18.936 SERIAL » [ACK] (0x06) 19:41:18.940 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.938 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:18.954 SERIAL « 0x0107001328000002c1 (9 bytes) 19:41:18.956 SERIAL Buffer := 0x0107001328000002c1 (9 bytes) 19:41:18.958 SERIAL » [ACK] (0x06) 19:41:18.965 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:18.962 DRIVER « [REQ] [SendData] [confirmation] callbackId: 40 transmitStatus: OK 19:41:18.963 DRIVER ACK received from node for current transaction. RTT = 95.96 ms 19:41:18.984 CNTRLR [Node 019] [+] [Configuration] 47: 3600 19:41:18.977 SERIAL « 0x010c000400130670062f020e10a7 (14 bytes) 19:41:18.978 SERIAL Buffer := 0x010c000400130670062f020e10a7 (14 bytes) 19:41:18.990 SERIAL » [ACK] (0x06) 19:41:18.998 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.014 SERIAL » 0x010a00130e03700501252993 (12 bytes) 19:41:18.993 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x2f020e10 19:41:18.994 DRIVER ACK already received, resolving transaction 19:41:18.996 DRIVER resuming send queue 19:41:19.013 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 41 └─[ConfigurationCCGet] payload: 0x01 19:41:19.016 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:19.000 CNTRLR » [Node 019] querying parameter #49 value... 19:41:19.064 SERIAL « [ACK] (0x06) 19:41:19.066 DRIVER ACK received from controller for current transaction 19:41:19.068 SERIAL « 0x060104011301e8 (7 bytes) 19:41:19.102 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:19.105 SERIAL » [ACK] (0x06) 19:41:19.114 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.108 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:19.122 SERIAL « 0x0107001329000002c0 (9 bytes) 19:41:19.123 SERIAL Buffer := 0x0107001329000002c0 (9 bytes) 19:41:19.125 SERIAL » [ACK] (0x06) 19:41:19.131 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.127 DRIVER « [REQ] [SendData] [confirmation] callbackId: 41 transmitStatus: OK 19:41:19.129 DRIVER ACK received from node for current transaction. RTT = 116.72 ms 19:41:19.190 CNTRLR [Node 014] [+] [Configuration] 1: 1 19:41:19.176 SERIAL « 0x010b0004000e0570060101018c (13 bytes) 19:41:19.178 SERIAL Buffer := 0x010b0004000e0570060101018c (13 bytes) 19:41:19.200 SERIAL » [ACK] (0x06) 19:41:19.210 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.252 SERIAL » 0x010a0013150386138e252ae4 (12 bytes) 19:41:19.205 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x010101 19:41:19.206 DRIVER ACK already received, resolving transaction 19:41:19.208 DRIVER resuming send queue 19:41:19.251 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 42 └─[VersionCCCommandClassGet] payload: 0x8e 19:41:19.254 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:19.214 CNTRLR » [Node 014] querying parameter #16 value... 19:41:19.298 SERIAL « [ACK] (0x06) 19:41:19.300 DRIVER ACK received from controller for current transaction 19:41:19.302 SERIAL « 0x060104011301e8 (7 bytes) 19:41:19.303 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:19.305 SERIAL » [ACK] (0x06) 19:41:19.310 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.307 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:19.323 SERIAL « 0x010700132a000003c2 (9 bytes) 19:41:19.324 SERIAL Buffer := 0x010700132a000003c2 (9 bytes) 19:41:19.325 SERIAL » [ACK] (0x06) 19:41:19.329 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.326 DRIVER « [REQ] [SendData] [confirmation] callbackId: 42 transmitStatus: OK 19:41:19.327 DRIVER ACK received from node for current transaction. RTT = 77.53 ms 19:41:19.343 CNTRLR [Node 021] supports CC Multi Channel Association (0x8e) in version 3 19:41:19.335 SERIAL « 0x010a000400150486148e03ff (12 bytes) 19:41:19.336 SERIAL Buffer := 0x010a000400150486148e03ff (12 bytes) 19:41:19.338 SERIAL » [ACK] (0x06) 19:41:19.343 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.356 SERIAL » 0x010a00131303700531252bbc (12 bytes) 19:41:19.340 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8e03 19:41:19.341 DRIVER ACK already received, resolving transaction 19:41:19.341 DRIVER resuming send queue 19:41:19.354 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 43 └─[ConfigurationCCGet] payload: 0x31 19:41:19.376 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:19.344 CNTRLR » [Node 021] querying the CC version for Association Group Information (0x59). .. 19:41:19.396 SERIAL « [ACK] (0x06) 19:41:19.397 DRIVER ACK received from controller for current transaction 19:41:19.398 SERIAL « 0x060104011301e8 (7 bytes) 19:41:19.399 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:19.400 SERIAL » [ACK] (0x06) 19:41:19.403 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.401 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:19.412 SERIAL « 0x010700132b000002c2 (9 bytes) 19:41:19.419 DRIVER « [REQ] [SendData] [confirmation] callbackId: 43 transmitStatus: OK 19:41:19.415 SERIAL Buffer := 0x010700132b000002c2 (9 bytes) 19:41:19.416 SERIAL » [ACK] (0x06) 19:41:19.423 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.421 DRIVER ACK received from node for current transaction. RTT = 68.19 ms 19:41:19.433 CNTRLR [Node 019] [+] [Configuration] 49: 0 19:41:19.426 SERIAL « 0x010b00040013057006310100a0 (13 bytes) 19:41:19.427 SERIAL Buffer := 0x010b00040013057006310100a0 (13 bytes) 19:41:19.438 SERIAL » [ACK] (0x06) 19:41:19.448 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.458 SERIAL » 0x010a00130e03700510252c87 (12 bytes) 19:41:19.445 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x310100 19:41:19.446 DRIVER ACK already received, resolving transaction 19:41:19.447 DRIVER resuming send queue 19:41:19.457 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 44 └─[ConfigurationCCGet] payload: 0x10 19:41:19.460 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:19.450 CNTRLR » [Node 019] querying parameter #50 value... 19:41:19.472 SERIAL « [ACK] (0x06) 19:41:19.475 DRIVER ACK received from controller for current transaction 19:41:19.477 SERIAL « 0x060104011301e8 (7 bytes) 19:41:19.478 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:19.480 SERIAL » [ACK] (0x06) 19:41:19.483 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.481 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:19.494 SERIAL « 0x010700132c000002c5 (9 bytes) 19:41:19.499 DRIVER « [REQ] [SendData] [confirmation] callbackId: 44 transmitStatus: OK 19:41:19.496 SERIAL Buffer := 0x010700132c000002c5 (9 bytes) 19:41:19.497 SERIAL » [ACK] (0x06) 19:41:19.502 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.500 DRIVER ACK received from node for current transaction. RTT = 44.13 ms 19:41:19.506 SERIAL « 0x010b0004000e0570061001019d (13 bytes) 19:41:19.512 CNTRLR [Node 014] [+] [Configuration] 16: 1 19:41:19.517 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x100101 19:41:19.508 SERIAL Buffer := 0x010b0004000e0570061001019d (13 bytes) 19:41:19.516 SERIAL » [ACK] (0x06) 19:41:19.521 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.527 SERIAL » 0x010a00131503861359252d34 (12 bytes) 19:41:19.522 CNTRLR » [Node 014] querying parameter #34 value... 19:41:19.519 DRIVER ACK already received, resolving transaction 19:41:19.520 DRIVER resuming send queue 19:41:19.526 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 45 └─[VersionCCCommandClassGet] payload: 0x59 19:41:19.528 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:19.534 SERIAL « [ACK] (0x06) 19:41:19.536 DRIVER ACK received from controller for current transaction 19:41:19.537 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.545 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:19.542 SERIAL « 0x0104011301e8 (6 bytes) 19:41:19.543 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:19.544 SERIAL » [ACK] (0x06) 19:41:19.547 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.565 SERIAL « 0x010700132d000003c5 (9 bytes) 19:41:19.570 DRIVER « [REQ] [SendData] [confirmation] callbackId: 45 transmitStatus: OK 19:41:19.566 SERIAL Buffer := 0x010700132d000003c5 (9 bytes) 19:41:19.568 SERIAL » [ACK] (0x06) 19:41:19.574 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.572 DRIVER ACK received from node for current transaction. RTT = 46.74 ms 19:41:19.594 CNTRLR [Node 021] supports CC Association Group Information (0x59) in version 2 19:41:19.579 SERIAL « 0x010a00040015048614590229 (12 bytes) 19:41:19.580 SERIAL Buffer := 0x010a00040015048614590229 (12 bytes) 19:41:19.583 SERIAL » [ACK] (0x06) 19:41:19.593 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.601 SERIAL » 0x010a00131303700532252eba (12 bytes) 19:41:19.590 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x5902 19:41:19.591 DRIVER ACK already received, resolving transaction 19:41:19.592 DRIVER resuming send queue 19:41:19.600 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 46 └─[ConfigurationCCGet] payload: 0x32 19:41:19.602 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:19.595 CNTRLR » [Node 021] querying the CC version for Configuration (0x70)... 19:41:19.615 SERIAL « [ACK] (0x06) 19:41:19.617 DRIVER ACK received from controller for current transaction 19:41:19.619 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.625 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:19.622 SERIAL « 0x0104011301e8 (6 bytes) 19:41:19.623 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:19.624 SERIAL » [ACK] (0x06) 19:41:19.627 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.634 SERIAL « 0x010700132e000002c7 (9 bytes) 19:41:19.637 DRIVER « [REQ] [SendData] [confirmation] callbackId: 46 transmitStatus: OK 19:41:19.635 SERIAL Buffer := 0x010700132e000002c7 (9 bytes) 19:41:19.636 SERIAL » [ACK] (0x06) 19:41:19.640 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.639 DRIVER ACK received from node for current transaction. RTT = 39.25 ms 19:41:19.646 SERIAL « 0x010c000400130670063202012c89 (14 bytes) 19:41:19.651 CNTRLR [Node 019] [+] [Configuration] 50: 300 19:41:19.657 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x3202012c 19:41:19.647 SERIAL Buffer := 0x010c000400130670063202012c89 (14 bytes) 19:41:19.655 SERIAL » [ACK] (0x06) 19:41:19.660 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.667 SERIAL » 0x010a00130e03700522252fb6 (12 bytes) 19:41:19.661 CNTRLR » [Node 019] querying parameter #51 value... 19:41:19.658 DRIVER ACK already received, resolving transaction 19:41:19.659 DRIVER resuming send queue 19:41:19.666 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 47 └─[ConfigurationCCGet] payload: 0x22 19:41:19.668 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:19.676 SERIAL « [ACK] (0x06) 19:41:19.678 DRIVER ACK received from controller for current transaction 19:41:19.680 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.687 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:19.683 SERIAL « 0x0104011301e8 (6 bytes) 19:41:19.684 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:19.685 SERIAL » [ACK] (0x06) 19:41:19.688 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.698 SERIAL « 0x010700132f000003c7 (9 bytes) 19:41:19.704 DRIVER « [REQ] [SendData] [confirmation] callbackId: 47 transmitStatus: OK 19:41:19.700 SERIAL Buffer := 0x010700132f000003c7 (9 bytes) 19:41:19.702 SERIAL » [ACK] (0x06) 19:41:19.707 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.705 DRIVER ACK received from node for current transaction. RTT = 40.09 ms 19:41:19.713 CNTRLR [Node 014] [+] [Configuration] 34: 63 19:41:19.709 SERIAL « 0x010b0004000e05700622013f91 (13 bytes) 19:41:19.710 SERIAL Buffer := 0x010b0004000e05700622013f91 (13 bytes) 19:41:19.717 SERIAL » [ACK] (0x06) 19:41:19.722 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.731 SERIAL » 0x010a00131503861370253000 (12 bytes) 19:41:19.719 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x22013f 19:41:19.720 DRIVER ACK already received, resolving transaction 19:41:19.721 DRIVER resuming send queue 19:41:19.730 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 48 └─[VersionCCCommandClassGet] payload: 0x70 19:41:19.732 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:19.723 CNTRLR » [Node 014] querying parameter #35 value... 19:41:19.743 SERIAL « [ACK] (0x06) 19:41:19.744 DRIVER ACK received from controller for current transaction 19:41:19.746 SERIAL « 0x060104011301 (6 bytes) 19:41:19.748 SERIAL [incomplete] Buffer := 0x0104011301 (5 bytes) 19:41:19.754 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:19.751 SERIAL « 0xe8 (1 bytes) 19:41:19.752 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:19.753 SERIAL » [ACK] (0x06) 19:41:19.756 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.768 SERIAL « 0x0107001330000002d9 (9 bytes) 19:41:19.773 DRIVER « [REQ] [SendData] [confirmation] callbackId: 48 transmitStatus: OK 19:41:19.770 SERIAL Buffer := 0x0107001330000002d9 (9 bytes) 19:41:19.771 SERIAL » [ACK] (0x06) 19:41:19.778 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.775 DRIVER ACK received from node for current transaction. RTT = 46.16 ms 19:41:19.794 CNTRLR [Node 021] supports CC Configuration (0x70) in version 1 19:41:19.785 SERIAL « 0x010a00040015048614700103 (12 bytes) 19:41:19.786 SERIAL Buffer := 0x010a00040015048614700103 (12 bytes) 19:41:19.788 SERIAL » [ACK] (0x06) 19:41:19.793 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.823 SERIAL » 0x010a001313037005332531a4 (12 bytes) 19:41:19.790 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x7001 19:41:19.791 DRIVER ACK already received, resolving transaction 19:41:19.792 DRIVER resuming send queue 19:41:19.821 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 49 └─[ConfigurationCCGet] payload: 0x33 19:41:19.798 CNTRLR [Node 021] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 19:41:19.799 CNTRLR [Node 021] trying to load device config 19:41:19.839 SERIAL « [ACK] (0x06) 19:41:19.841 DRIVER ACK received from controller for current transaction 19:41:19.843 SERIAL « 0x060104011301e8 (7 bytes) 19:41:19.845 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:19.846 SERIAL » [ACK] (0x06) 19:41:19.851 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.848 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:19.915 CNTRLR [Node 021] device config loaded 19:41:19.917 SERIAL « 0x0107001331000002d8 (9 bytes) 19:41:19.921 DRIVER « [REQ] [SendData] [confirmation] callbackId: 49 transmitStatus: OK 19:41:19.918 SERIAL Buffer := 0x0107001331000002d8 (9 bytes) 19:41:19.920 SERIAL » [ACK] (0x06) 19:41:19.924 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.922 DRIVER ACK received from node for current transaction. RTT = 102.60 ms 19:41:19.931 CNTRLR [Node 019] [+] [Configuration] 51: 500 19:41:19.927 SERIAL « 0x010c00040013067006330201f450 (14 bytes) 19:41:19.927 SERIAL Buffer := 0x010c00040013067006330201f450 (14 bytes) 19:41:19.937 SERIAL » [ACK] (0x06) 19:41:19.942 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:19.949 SERIAL » 0x010a00130e037005232532aa (12 bytes) 19:41:19.939 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x330201f4 19:41:19.940 DRIVER ACK already received, resolving transaction 19:41:19.941 DRIVER resuming send queue 19:41:19.948 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 50 └─[ConfigurationCCGet] payload: 0x23 19:41:19.951 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:19.943 CNTRLR » [Node 019] querying parameter #52 value... 19:41:20.048 SERIAL « [ACK] (0x06) 19:41:20.056 DRIVER ACK received from controller for current transaction 19:41:20.072 CNTRLR [Node 021] ZWavePlusCC: doing a complete interview... 19:41:20.058 SERIAL « 0x060104011301e8 (7 bytes) 19:41:20.060 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:20.062 SERIAL » [ACK] (0x06) 19:41:20.066 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.064 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:20.073 CNTRLR » [Node 021] querying Z-Wave+ information... 19:41:20.083 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:20.090 SERIAL « 0x0107001332000002db (9 bytes) 19:41:20.098 DRIVER « [REQ] [SendData] [confirmation] callbackId: 50 transmitStatus: OK 19:41:20.095 SERIAL Buffer := 0x0107001332000002db (9 bytes) 19:41:20.096 SERIAL » [ACK] (0x06) 19:41:20.101 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.099 DRIVER ACK received from node for current transaction. RTT = 152.07 ms 19:41:20.108 CNTRLR [Node 014] [+] [Configuration] 35: 0 19:41:20.103 SERIAL « 0x010b0004000e057006230100af (13 bytes) 19:41:20.104 SERIAL Buffer := 0x010b0004000e057006230100af (13 bytes) 19:41:20.112 SERIAL » [ACK] (0x06) 19:41:20.117 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.126 SERIAL » 0x010a001313037005342533a1 (12 bytes) 19:41:20.114 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x230100 19:41:20.115 DRIVER ACK already received, resolving transaction 19:41:20.116 DRIVER resuming send queue 19:41:20.125 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 51 └─[ConfigurationCCGet] payload: 0x34 19:41:20.127 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:20.118 CNTRLR » [Node 014] querying parameter #39 value... 19:41:20.134 SERIAL « [ACK] (0x06) 19:41:20.139 DRIVER ACK received from controller for current transaction 19:41:20.140 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.154 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:20.147 SERIAL « 0x0104011301e8 (6 bytes) 19:41:20.148 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:20.153 SERIAL » [ACK] (0x06) 19:41:20.156 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.174 SERIAL « 0x0107001333000002da (9 bytes) 19:41:20.179 DRIVER « [REQ] [SendData] [confirmation] callbackId: 51 transmitStatus: OK 19:41:20.175 SERIAL Buffer := 0x0107001333000002da (9 bytes) 19:41:20.177 SERIAL » [ACK] (0x06) 19:41:20.183 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.193 CNTRLR [Node 019] [+] [Configuration] 52: 6 19:41:20.181 DRIVER ACK received from node for current transaction. RTT = 56.34 ms 19:41:20.201 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x340106 19:41:20.202 DRIVER ACK already received, resolving transaction 19:41:20.203 DRIVER resuming send queue 19:41:20.213 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 52 └─[ConfigurationCCGet] payload: 0x27 19:41:20.216 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:20.187 SERIAL « 0x010b00040013057006340106a3 (13 bytes) 19:41:20.188 SERIAL Buffer := 0x010b00040013057006340106a3 (13 bytes) 19:41:20.198 SERIAL » [ACK] (0x06) 19:41:20.205 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.215 SERIAL » 0x010a00130e037005272534a8 (12 bytes) 19:41:20.206 CNTRLR » [Node 019] querying parameter #60 value... 19:41:20.224 SERIAL « [ACK] (0x06) 19:41:20.225 DRIVER ACK received from controller for current transaction 19:41:20.231 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.237 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:20.234 SERIAL « 0x0104011301e8 (6 bytes) 19:41:20.235 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:20.236 SERIAL » [ACK] (0x06) 19:41:20.239 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.262 SERIAL « 0x0107001334000002dd (9 bytes) 19:41:20.269 DRIVER « [REQ] [SendData] [confirmation] callbackId: 52 transmitStatus: OK 19:41:20.265 SERIAL Buffer := 0x0107001334000002dd (9 bytes) 19:41:20.267 SERIAL » [ACK] (0x06) 19:41:20.273 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.271 DRIVER ACK received from node for current transaction. RTT = 58.25 ms 19:41:20.285 CNTRLR [Node 014] [+] [Configuration] 39: 600 19:41:20.276 SERIAL « 0x010c0004000e06700627020258f6 (14 bytes) 19:41:20.278 SERIAL Buffer := 0x010c0004000e06700627020258f6 (14 bytes) 19:41:20.292 SERIAL » [ACK] (0x06) 19:41:20.299 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.315 SERIAL » 0x010a0013130370053c2535af (12 bytes) 19:41:20.294 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x27020258 19:41:20.295 DRIVER ACK already received, resolving transaction 19:41:20.296 DRIVER resuming send queue 19:41:20.314 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 53 └─[ConfigurationCCGet] payload: 0x3c 19:41:20.316 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:20.301 CNTRLR » [Node 014] querying parameter #40 value... 19:41:20.324 SERIAL « [ACK] (0x06) 19:41:20.325 DRIVER ACK received from controller for current transaction 19:41:20.330 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.336 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:20.333 SERIAL « 0x0104011301e8 (6 bytes) 19:41:20.334 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:20.335 SERIAL » [ACK] (0x06) 19:41:20.337 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.350 SERIAL « 0x0107001335000002dc (9 bytes) 19:41:20.354 DRIVER « [REQ] [SendData] [confirmation] callbackId: 53 transmitStatus: OK 19:41:20.351 SERIAL Buffer := 0x0107001335000002dc (9 bytes) 19:41:20.353 SERIAL » [ACK] (0x06) 19:41:20.359 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.357 DRIVER ACK received from node for current transaction. RTT = 48.74 ms 19:41:20.370 SERIAL « 0x010c000400130670063c0261a863 (14 bytes) 19:41:20.374 CNTRLR [Node 019] [+] [Configuration] 60: 25000 19:41:20.380 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x3c0261a8 19:41:20.370 SERIAL Buffer := 0x010c000400130670063c0261a863 (14 bytes) 19:41:20.378 SERIAL » [ACK] (0x06) 19:41:20.383 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.389 SERIAL » 0x010a00130e037005282536a5 (12 bytes) 19:41:20.384 CNTRLR » [Node 019] querying parameter #61 value... 19:41:20.381 DRIVER ACK already received, resolving transaction 19:41:20.382 DRIVER resuming send queue 19:41:20.388 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 54 └─[ConfigurationCCGet] payload: 0x28 19:41:20.391 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:20.396 SERIAL « [ACK] (0x06) 19:41:20.398 DRIVER ACK received from controller for current transaction 19:41:20.402 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.409 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:20.405 SERIAL « 0x0104011301e8 (6 bytes) 19:41:20.406 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:20.407 SERIAL » [ACK] (0x06) 19:41:20.411 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.422 SERIAL « 0x0107001336000002df (9 bytes) 19:41:20.428 DRIVER « [REQ] [SendData] [confirmation] callbackId: 54 transmitStatus: OK 19:41:20.424 SERIAL Buffer := 0x0107001336000002df (9 bytes) 19:41:20.426 SERIAL » [ACK] (0x06) 19:41:20.432 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.430 DRIVER ACK received from node for current transaction. RTT = 41.63 ms 19:41:20.440 CNTRLR [Node 014] [+] [Configuration] 40: 80 19:41:20.435 SERIAL « 0x010b0004000e057006280150f4 (13 bytes) 19:41:20.436 SERIAL Buffer := 0x010b0004000e057006280150f4 (13 bytes) 19:41:20.444 SERIAL » [ACK] (0x06) 19:41:20.448 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.456 SERIAL » 0x010a0013130370053d2537ac (12 bytes) 19:41:20.446 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x280150 19:41:20.446 DRIVER ACK already received, resolving transaction 19:41:20.447 DRIVER resuming send queue 19:41:20.456 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 55 └─[ConfigurationCCGet] payload: 0x3d 19:41:20.457 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:20.449 CNTRLR » [Node 014] querying parameter #42 value... 19:41:20.469 SERIAL « [ACK] (0x06) 19:41:20.473 DRIVER ACK received from controller for current transaction 19:41:20.474 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.479 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:20.476 SERIAL « 0x0104011301e8 (6 bytes) 19:41:20.477 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:20.478 SERIAL » [ACK] (0x06) 19:41:20.480 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.493 SERIAL « 0x0107001337000003df (9 bytes) 19:41:20.498 DRIVER « [REQ] [SendData] [confirmation] callbackId: 55 transmitStatus: OK 19:41:20.495 SERIAL Buffer := 0x0107001337000003df (9 bytes) 19:41:20.496 SERIAL » [ACK] (0x06) 19:41:20.503 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.500 DRIVER ACK received from node for current transaction. RTT = 45.42 ms 19:41:20.510 CNTRLR [Node 019] [+] [Configuration] 61: 1 19:41:20.506 SERIAL « 0x010b000400130570063d0101ad (13 bytes) 19:41:20.507 SERIAL Buffer := 0x010b000400130570063d0101ad (13 bytes) 19:41:20.514 SERIAL » [ACK] (0x06) 19:41:20.519 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.527 SERIAL » 0x010a00130e0370052a2538a9 (12 bytes) 19:41:20.516 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x3d0101 19:41:20.517 DRIVER ACK already received, resolving transaction 19:41:20.518 DRIVER resuming send queue 19:41:20.526 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 56 └─[ConfigurationCCGet] payload: 0x2a 19:41:20.528 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:20.520 CNTRLR » [Node 019] querying parameter #62 value... 19:41:20.540 SERIAL « [ACK] (0x06) 19:41:20.544 DRIVER ACK received from controller for current transaction 19:41:20.545 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.551 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:20.548 SERIAL « 0x0104011301e8 (6 bytes) 19:41:20.549 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:20.550 SERIAL » [ACK] (0x06) 19:41:20.552 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.564 SERIAL « 0x0107001338000003d0 (9 bytes) 19:41:20.570 DRIVER « [REQ] [SendData] [confirmation] callbackId: 56 transmitStatus: OK 19:41:20.565 SERIAL Buffer := 0x0107001338000003d0 (9 bytes) 19:41:20.568 SERIAL » [ACK] (0x06) 19:41:20.575 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.572 DRIVER ACK received from node for current transaction. RTT = 46.86 ms 19:41:20.582 CNTRLR [Node 014] [+] [Configuration] 42: 15 19:41:20.578 SERIAL « 0x010b0004000e0570062a010fa9 (13 bytes) 19:41:20.578 SERIAL Buffer := 0x010b0004000e0570062a010fa9 (13 bytes) 19:41:20.586 SERIAL » [ACK] (0x06) 19:41:20.590 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.598 SERIAL » 0x010a0013130370053e2539a1 (12 bytes) 19:41:20.587 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x2a010f 19:41:20.588 DRIVER ACK already received, resolving transaction 19:41:20.589 DRIVER resuming send queue 19:41:20.597 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 57 └─[ConfigurationCCGet] payload: 0x3e 19:41:20.599 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:20.591 CNTRLR » [Node 014] querying parameter #43 value... 19:41:20.610 SERIAL « [ACK] (0x06) 19:41:20.613 DRIVER ACK received from controller for current transaction 19:41:20.615 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.622 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:20.618 SERIAL « 0x0104011301e8 (6 bytes) 19:41:20.619 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:20.620 SERIAL » [ACK] (0x06) 19:41:20.623 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.641 SERIAL « 0x0107001339000003d1 (9 bytes) 19:41:20.648 DRIVER « [REQ] [SendData] [confirmation] callbackId: 57 transmitStatus: OK 19:41:20.645 SERIAL Buffer := 0x0107001339000003d1 (9 bytes) 19:41:20.647 SERIAL » [ACK] (0x06) 19:41:20.651 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.650 DRIVER ACK received from node for current transaction. RTT = 53.32 ms 19:41:20.661 CNTRLR [Node 019] [+] [Configuration] 62: 8 19:41:20.656 SERIAL « 0x010b000400130570063e0108a7 (13 bytes) 19:41:20.657 SERIAL Buffer := 0x010b000400130570063e0108a7 (13 bytes) 19:41:20.666 SERIAL » [ACK] (0x06) 19:41:20.671 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.681 SERIAL » 0x010a00130e0370052b253aaa (12 bytes) 19:41:20.668 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x3e0108 19:41:20.669 DRIVER ACK already received, resolving transaction 19:41:20.670 DRIVER resuming send queue 19:41:20.680 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 58 └─[ConfigurationCCGet] payload: 0x2b 19:41:20.682 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:20.673 CNTRLR » [Node 019] querying parameter #63 value... 19:41:20.690 SERIAL « [ACK] (0x06) 19:41:20.691 DRIVER ACK received from controller for current transaction 19:41:20.693 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.702 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:20.697 SERIAL « 0x0104011301e8 (6 bytes) 19:41:20.699 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:20.700 SERIAL » [ACK] (0x06) 19:41:20.704 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.718 SERIAL « 0x010700133a000002d3 (9 bytes) 19:41:20.726 DRIVER « [REQ] [SendData] [confirmation] callbackId: 58 transmitStatus: OK 19:41:20.720 SERIAL Buffer := 0x010700133a000002d3 (9 bytes) 19:41:20.723 SERIAL » [ACK] (0x06) 19:41:20.729 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.728 DRIVER ACK received from node for current transaction. RTT = 48.52 ms 19:41:20.739 SERIAL « 0x010b0004000e0570062b011eb9 (13 bytes) 19:41:20.743 CNTRLR [Node 014] [+] [Configuration] 43: 30 19:41:20.749 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x2b011e 19:41:20.740 SERIAL Buffer := 0x010b0004000e0570062b011eb9 (13 bytes) 19:41:20.747 SERIAL » [ACK] (0x06) 19:41:20.752 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.758 SERIAL » 0x010a0013130370053f253ba2 (12 bytes) 19:41:20.753 CNTRLR » [Node 014] querying parameter #45 value... 19:41:20.750 DRIVER ACK already received, resolving transaction 19:41:20.751 DRIVER resuming send queue 19:41:20.757 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 59 └─[ConfigurationCCGet] payload: 0x3f 19:41:20.759 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:20.764 SERIAL « [ACK] (0x06) 19:41:20.769 DRIVER ACK received from controller for current transaction 19:41:20.771 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.780 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:20.777 SERIAL « 0x0104011301e8 (6 bytes) 19:41:20.778 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:20.779 SERIAL » [ACK] (0x06) 19:41:20.781 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.790 SERIAL « 0x010700133b000003d3 (9 bytes) 19:41:20.798 DRIVER « [REQ] [SendData] [confirmation] callbackId: 59 transmitStatus: OK 19:41:20.792 SERIAL Buffer := 0x010700133b000003d3 (9 bytes) 19:41:20.794 SERIAL » [ACK] (0x06) 19:41:20.801 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.800 DRIVER ACK received from node for current transaction. RTT = 43.41 ms 19:41:20.809 CNTRLR [Node 019] [+] [Configuration] 63: 1 19:41:20.804 SERIAL « 0x010b000400130570063f0101af (13 bytes) 19:41:20.805 SERIAL Buffer := 0x010b000400130570063f0101af (13 bytes) 19:41:20.813 SERIAL » [ACK] (0x06) 19:41:20.818 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.827 SERIAL » 0x010a00130e0370052d253caa (12 bytes) 19:41:20.815 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x3f0101 19:41:20.816 DRIVER ACK already received, resolving transaction 19:41:20.817 DRIVER resuming send queue 19:41:20.825 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 60 └─[ConfigurationCCGet] payload: 0x2d 19:41:20.828 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:20.819 CNTRLR » [Node 019] querying parameter #70 value... 19:41:20.839 SERIAL « [ACK] (0x06) 19:41:20.847 DRIVER ACK received from controller for current transaction 19:41:20.849 SERIAL « 0x060104011301e8 (7 bytes) 19:41:20.849 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:20.850 SERIAL » [ACK] (0x06) 19:41:20.852 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.851 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:20.863 SERIAL « 0x010700133c000002d5 (9 bytes) 19:41:20.870 DRIVER « [REQ] [SendData] [confirmation] callbackId: 60 transmitStatus: OK 19:41:20.867 SERIAL Buffer := 0x010700133c000002d5 (9 bytes) 19:41:20.869 SERIAL » [ACK] (0x06) 19:41:20.873 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.871 DRIVER ACK received from node for current transaction. RTT = 46.84 ms 19:41:20.883 SERIAL « 0x010b0004000e0570062d010aab (13 bytes) 19:41:20.891 CNTRLR [Node 014] [+] [Configuration] 45: 10 19:41:20.896 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x2d010a 19:41:20.884 SERIAL Buffer := 0x010b0004000e0570062d010aab (13 bytes) 19:41:20.895 SERIAL » [ACK] (0x06) 19:41:20.899 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.905 SERIAL » 0x010a00131303700546253ddd (12 bytes) 19:41:20.901 CNTRLR » [Node 014] querying parameter #47 value... 19:41:20.897 DRIVER ACK already received, resolving transaction 19:41:20.898 DRIVER resuming send queue 19:41:20.904 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 61 └─[ConfigurationCCGet] payload: 0x46 19:41:20.906 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:20.920 SERIAL « [ACK] (0x06) 19:41:20.923 DRIVER ACK received from controller for current transaction 19:41:20.924 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.936 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:20.931 SERIAL « 0x0104011301e8 (6 bytes) 19:41:20.934 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:20.935 SERIAL » [ACK] (0x06) 19:41:20.938 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.948 SERIAL « 0x010700133d000002d4 (9 bytes) 19:41:20.954 DRIVER « [REQ] [SendData] [confirmation] callbackId: 61 transmitStatus: OK 19:41:20.951 SERIAL Buffer := 0x010700133d000002d4 (9 bytes) 19:41:20.952 SERIAL » [ACK] (0x06) 19:41:20.957 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.955 DRIVER ACK received from node for current transaction. RTT = 51.85 ms 19:41:20.969 SERIAL « 0x010c000400130670064602ffffd0 (14 bytes) 19:41:20.974 CNTRLR [Node 019] [+] [Configuration] 70: 65535 19:41:20.980 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x4602ffff 19:41:20.971 SERIAL Buffer := 0x010c000400130670064602ffffd0 (14 bytes) 19:41:20.978 SERIAL » [ACK] (0x06) 19:41:20.982 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:20.991 SERIAL » 0x010a00130e0370052f253eaa (12 bytes) 19:41:20.984 CNTRLR [Node 019] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 19:41:20.981 DRIVER ACK already received, resolving transaction 19:41:20.981 DRIVER resuming send queue 19:41:20.990 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 62 └─[ConfigurationCCGet] payload: 0x2f 19:41:21.059 SERIAL « [ACK] (0x06) 19:41:21.061 DRIVER ACK received from controller for current transaction 19:41:21.062 SERIAL « 0x060104011301e8 (7 bytes) 19:41:21.064 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:21.065 SERIAL » [ACK] (0x06) 19:41:21.068 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.066 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:21.075 SERIAL « 0x010700133e000002d7 (9 bytes) 19:41:21.076 SERIAL Buffer := 0x010700133e000002d7 (9 bytes) 19:41:21.077 SERIAL » [ACK] (0x06) 19:41:21.081 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.079 DRIVER « [REQ] [SendData] [confirmation] callbackId: 62 transmitStatus: OK 19:41:21.080 DRIVER ACK received from node for current transaction. RTT = 91.24 ms 19:41:21.092 CNTRLR [Node 014] [+] [Configuration] 47: 3600 19:41:21.087 SERIAL « 0x010c0004000e0670062f020e10ba (14 bytes) 19:41:21.088 SERIAL Buffer := 0x010c0004000e0670062f020e10ba (14 bytes) 19:41:21.095 SERIAL » [ACK] (0x06) 19:41:21.100 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.107 SERIAL » 0x010a00130e03700531253fb5 (12 bytes) 19:41:21.097 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x2f020e10 19:41:21.098 DRIVER ACK already received, resolving transaction 19:41:21.099 DRIVER resuming send queue 19:41:21.106 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 63 └─[ConfigurationCCGet] payload: 0x31 19:41:21.108 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:21.101 CNTRLR » [Node 014] querying parameter #49 value... 19:41:21.115 SERIAL « [ACK] (0x06) 19:41:21.116 DRIVER ACK received from controller for current transaction 19:41:21.120 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.126 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:21.123 SERIAL « 0x0104011301e8 (6 bytes) 19:41:21.124 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:21.125 SERIAL » [ACK] (0x06) 19:41:21.128 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.140 SERIAL « 0x010700133f000003d7 (9 bytes) 19:41:21.147 DRIVER « [REQ] [SendData] [confirmation] callbackId: 63 transmitStatus: OK 19:41:21.142 SERIAL Buffer := 0x010700133f000003d7 (9 bytes) 19:41:21.145 SERIAL » [ACK] (0x06) 19:41:21.153 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.150 DRIVER ACK received from node for current transaction. RTT = 43.53 ms 19:41:21.160 CNTRLR [Node 014] [+] [Configuration] 49: 0 19:41:21.155 SERIAL « 0x010b0004000e057006310100bd (13 bytes) 19:41:21.156 SERIAL Buffer := 0x010b0004000e057006310100bd (13 bytes) 19:41:21.164 SERIAL » [ACK] (0x06) 19:41:21.178 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.189 SERIAL » 0x010a00130e037005322540c9 (12 bytes) 19:41:21.166 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x310100 19:41:21.175 DRIVER ACK already received, resolving transaction 19:41:21.176 DRIVER resuming send queue 19:41:21.188 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 64 └─[ConfigurationCCGet] payload: 0x32 19:41:21.191 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:21.179 CNTRLR » [Node 014] querying parameter #50 value... 19:41:21.203 SERIAL « [ACK] (0x06) 19:41:21.209 DRIVER ACK received from controller for current transaction 19:41:21.211 SERIAL « 0x060104011301e8 (7 bytes) 19:41:21.212 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:21.213 SERIAL » [ACK] (0x06) 19:41:21.216 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.214 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:21.239 SERIAL « 0x0107001340000002a9 (9 bytes) 19:41:21.247 DRIVER « [REQ] [SendData] [confirmation] callbackId: 64 transmitStatus: OK 19:41:21.266 CNTRLR [Node 019] AssociationCC: skipping interview because Multi Channel Association is supported... 19:41:21.243 SERIAL Buffer := 0x0107001340000002a9 (9 bytes) 19:41:21.245 SERIAL » [ACK] (0x06) 19:41:21.252 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.248 DRIVER ACK received from node for current transaction. RTT = 60.94 ms 19:41:21.269 CNTRLR [Node 019] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 19:41:21.274 CNTRLR [Node 019] BinarySwitchCC: doing a complete interview... 19:41:21.276 CNTRLR » [Node 019] querying Binary Switch state... 19:41:21.289 CNTRLR [Node 014] [+] [Configuration] 50: 300 19:41:21.306 CNTRLR » [Node 014] querying parameter #51 value... 19:41:21.282 SERIAL « 0x010c0004000e0670063202012c94 (14 bytes) 19:41:21.284 SERIAL Buffer := 0x010c0004000e0670063202012c94 (14 bytes) 19:41:21.294 SERIAL » [ACK] (0x06) 19:41:21.305 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.323 SERIAL » 0x01090013130225022541b7 (11 bytes) 19:41:21.298 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x3202012c 19:41:21.300 DRIVER ACK already received, resolving transaction 19:41:21.301 DRIVER resuming send queue 19:41:21.322 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 65 └─[BinarySwitchCCGet] 19:41:21.328 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:21.331 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:21.342 SERIAL « [ACK] (0x06) 19:41:21.344 DRIVER ACK received from controller for current transaction 19:41:21.345 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.353 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:21.348 SERIAL « 0x0104011301e8 (6 bytes) 19:41:21.349 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:21.351 SERIAL » [ACK] (0x06) 19:41:21.355 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.367 SERIAL « 0x0107001341000002a8 (9 bytes) 19:41:21.374 DRIVER « [REQ] [SendData] [confirmation] callbackId: 65 transmitStatus: OK 19:41:21.370 SERIAL Buffer := 0x0107001341000002a8 (9 bytes) 19:41:21.372 SERIAL » [ACK] (0x06) 19:41:21.377 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.376 DRIVER ACK received from node for current transaction. RTT = 56.49 ms 19:41:21.393 CNTRLR [Node 019] [+] [Binary Switch] currentValue: true [Endpoint 0] 19:41:21.383 SERIAL « 0x010900040013032503ff3b (11 bytes) 19:41:21.384 SERIAL Buffer := 0x010900040013032503ff3b (11 bytes) 19:41:21.398 SERIAL » [ACK] (0x06) 19:41:21.406 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.426 SERIAL » 0x010a00130e037005332542ca (12 bytes) 19:41:21.409 CNTRLR « [Node 019] received Binary Switch state: current value: true 19:41:21.413 CNTRLR [Node 019] [+] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] 19:41:21.400 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[BinarySwitchCCReport] payload: 0xff 19:41:21.403 DRIVER ACK already received, resolving transaction 19:41:21.404 DRIVER resuming send queue 19:41:21.424 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 66 └─[ConfigurationCCGet] payload: 0x33 19:41:21.517 SERIAL « [ACK] (0x06) 19:41:21.519 DRIVER ACK received from controller for current transaction 19:41:21.520 SERIAL « 0x060104011301e8 (7 bytes) 19:41:21.523 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:21.524 SERIAL » [ACK] (0x06) 19:41:21.528 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.526 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:21.534 SERIAL « 0x0107001342000002ab (9 bytes) 19:41:21.535 SERIAL Buffer := 0x0107001342000002ab (9 bytes) 19:41:21.536 SERIAL » [ACK] (0x06) 19:41:21.540 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.537 DRIVER « [REQ] [SendData] [confirmation] callbackId: 66 transmitStatus: OK 19:41:21.538 DRIVER ACK received from node for current transaction. RTT = 116.75 ms 19:41:21.554 CNTRLR [Node 019] MeterCC: doing a complete interview... 19:41:21.563 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:21.556 CNTRLR » [Node 019] querying meter support... 19:41:21.568 SERIAL « 0x010c0004000e067006330201f44d (14 bytes) 19:41:21.573 CNTRLR [Node 014] [+] [Configuration] 51: 500 19:41:21.578 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x330201f4 19:41:21.569 SERIAL Buffer := 0x010c0004000e067006330201f44d (14 bytes) 19:41:21.576 SERIAL » [ACK] (0x06) 19:41:21.581 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.587 SERIAL » 0x01090013130232032543a3 (11 bytes) 19:41:21.582 CNTRLR » [Node 014] querying parameter #52 value... 19:41:21.579 DRIVER ACK already received, resolving transaction 19:41:21.580 DRIVER resuming send queue 19:41:21.586 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 67 └─[MeterCCSupportedGet] 19:41:21.589 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:21.595 SERIAL « [ACK] (0x06) 19:41:21.596 DRIVER ACK received from controller for current transaction 19:41:21.598 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.605 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:21.601 SERIAL « 0x0104011301e8 (6 bytes) 19:41:21.602 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:21.603 SERIAL » [ACK] (0x06) 19:41:21.607 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.618 SERIAL « 0x0107001343000003ab (9 bytes) 19:41:21.623 DRIVER « [REQ] [SendData] [confirmation] callbackId: 67 transmitStatus: OK 19:41:21.619 SERIAL Buffer := 0x0107001343000003ab (9 bytes) 19:41:21.621 SERIAL » [ACK] (0x06) 19:41:21.627 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.624 DRIVER ACK received from node for current transaction. RTT = 38.45 ms 19:41:21.662 CNTRLR « [Node 019] received meter support: type: Electric supported scales: · kWh, · W supported rate types: supports reset: true 19:41:21.642 SERIAL « 0x010a00040013043204810554 (12 bytes) 19:41:21.644 SERIAL Buffer := 0x010a00040013043204810554 (12 bytes) 19:41:21.651 SERIAL » [ACK] (0x06) 19:41:21.656 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.688 SERIAL » 0x010a00130e037005342544cb (12 bytes) 19:41:21.653 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[MeterCCSupportedReport] payload: 0x8105 19:41:21.654 DRIVER ACK already received, resolving transaction 19:41:21.654 DRIVER resuming send queue 19:41:21.686 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 68 └─[ConfigurationCCGet] payload: 0x34 19:41:21.689 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:21.664 CNTRLR » [Node 019] querying meter value (type = Electric, scale = kWh)... 19:41:21.696 SERIAL « [ACK] (0x06) 19:41:21.697 DRIVER ACK received from controller for current transaction 19:41:21.699 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.706 SERIAL « 0x0104011301e8 (6 bytes) 19:41:21.709 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:21.707 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:21.708 SERIAL » [ACK] (0x06) 19:41:21.710 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.718 SERIAL « 0x0107001344000002ad (9 bytes) 19:41:21.723 DRIVER « [REQ] [SendData] [confirmation] callbackId: 68 transmitStatus: OK 19:41:21.720 SERIAL Buffer := 0x0107001344000002ad (9 bytes) 19:41:21.721 SERIAL » [ACK] (0x06) 19:41:21.727 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.725 DRIVER ACK received from node for current transaction. RTT = 39.36 ms 19:41:21.735 CNTRLR [Node 014] [+] [Configuration] 52: 6 19:41:21.730 SERIAL « 0x010b0004000e057006340106be (13 bytes) 19:41:21.731 SERIAL Buffer := 0x010b0004000e057006340106be (13 bytes) 19:41:21.739 SERIAL » [ACK] (0x06) 19:41:21.743 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.753 SERIAL » 0x010a001313033201002545a5 (12 bytes) 19:41:21.741 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x340106 19:41:21.742 DRIVER ACK already received, resolving transaction 19:41:21.742 DRIVER resuming send queue 19:41:21.752 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 69 └─[MeterCCGet] payload: 0x00 19:41:21.754 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:21.745 CNTRLR » [Node 014] querying parameter #60 value... 19:41:21.759 SERIAL « [ACK] (0x06) 19:41:21.760 DRIVER ACK received from controller for current transaction 19:41:21.761 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.766 SERIAL « 0x0104011301e8 (6 bytes) 19:41:21.770 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:21.767 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:21.768 SERIAL » [ACK] (0x06) 19:41:21.772 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.783 SERIAL « 0x0107001345000002ac (9 bytes) 19:41:21.789 DRIVER « [REQ] [SendData] [confirmation] callbackId: 69 transmitStatus: OK 19:41:21.784 SERIAL Buffer := 0x0107001345000002ac (9 bytes) 19:41:21.786 SERIAL » [ACK] (0x06) 19:41:21.792 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.791 DRIVER ACK received from node for current transaction. RTT = 42.35 ms 19:41:21.811 CNTRLR [Node 019] [Meter] value[65537]: metadata updated [Endpoint 0] 19:41:21.795 SERIAL « 0x0110000400130a3202214400000e8500002c (18 bytes) 19:41:21.796 SERIAL Buffer := 0x0110000400130a3202214400000e8500002c (18 bytes) 19:41:21.833 SERIAL » [ACK] (0x06) 19:41:21.841 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.851 SERIAL » 0x010a00130e0370053c2546c1 (12 bytes) 19:41:21.836 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[MeterCCReport] payload: 0x214400000e850000 19:41:21.837 DRIVER ACK already received, resolving transaction 19:41:21.838 DRIVER resuming send queue 19:41:21.849 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 70 └─[ConfigurationCCGet] payload: 0x3c 19:41:21.852 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:21.818 CNTRLR [Node 019] [+] [Meter] value[65537]: 37.17 [Endpoint 0] 19:41:21.823 CNTRLR [Node 019] [Meter] deltaTime[65537]: metadata updated [Endpoint 0] 19:41:21.830 CNTRLR [Node 019] [+] [Meter] deltaTime[65537]: 0 [Endpoint 0] 19:41:21.844 CNTRLR » [Node 019] querying meter value (type = Electric, scale = W)... 19:41:21.856 SERIAL « [ACK] (0x06) 19:41:21.857 DRIVER ACK received from controller for current transaction 19:41:21.859 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.863 SERIAL « 0x0104011301e8 (6 bytes) 19:41:21.867 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:21.864 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:21.865 SERIAL » [ACK] (0x06) 19:41:21.870 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.880 SERIAL « 0x0107001346000002af (9 bytes) 19:41:21.885 DRIVER « [REQ] [SendData] [confirmation] callbackId: 70 transmitStatus: OK 19:41:21.881 SERIAL Buffer := 0x0107001346000002af (9 bytes) 19:41:21.883 SERIAL » [ACK] (0x06) 19:41:21.888 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.886 DRIVER ACK received from node for current transaction. RTT = 37.96 ms 19:41:21.895 CNTRLR [Node 014] [+] [Configuration] 60: 25000 19:41:21.891 SERIAL « 0x010c0004000e0670063c0261a87e (14 bytes) 19:41:21.892 SERIAL Buffer := 0x010c0004000e0670063c0261a87e (14 bytes) 19:41:21.899 SERIAL » [ACK] (0x06) 19:41:21.904 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.912 SERIAL » 0x010a001313033201102547b7 (12 bytes) 19:41:21.901 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x3c0261a8 19:41:21.902 DRIVER ACK already received, resolving transaction 19:41:21.903 DRIVER resuming send queue 19:41:21.911 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 71 └─[MeterCCGet] payload: 0x10 19:41:21.913 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:21.905 CNTRLR » [Node 014] querying parameter #61 value... 19:41:21.918 SERIAL « [ACK] (0x06) 19:41:21.920 DRIVER ACK received from controller for current transaction 19:41:21.921 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.925 SERIAL « 0x0104011301e8 (6 bytes) 19:41:21.929 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:21.926 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:21.927 SERIAL » [ACK] (0x06) 19:41:21.931 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.941 SERIAL « 0x0107001347000002ae (9 bytes) 19:41:21.944 DRIVER « [REQ] [SendData] [confirmation] callbackId: 71 transmitStatus: OK 19:41:21.942 SERIAL Buffer := 0x0107001347000002ae (9 bytes) 19:41:21.943 SERIAL » [ACK] (0x06) 19:41:21.947 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.946 DRIVER ACK received from node for current transaction. RTT = 35.77 ms 19:41:21.953 SERIAL « 0x010e00040013083202213200190000d4 (16 bytes) 19:41:21.959 CNTRLR [Node 019] [Meter] value[66049]: metadata updated [Endpoint 0] 19:41:21.978 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[MeterCCReport] payload: 0x213200190000 19:41:21.954 SERIAL Buffer := 0x010e00040013083202213200190000d4 (16 bytes) 19:41:21.976 SERIAL » [ACK] (0x06) 19:41:21.981 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:21.995 SERIAL » 0x010a00130e0370053d2548ce (12 bytes) 19:41:21.964 CNTRLR [Node 019] [+] [Meter] value[66049]: 2.5 [Endpoint 0] 19:41:21.969 CNTRLR [Node 019] [Meter] deltaTime[66049]: metadata updated [Endpoint 0] 19:41:21.973 CNTRLR [Node 019] [+] [Meter] deltaTime[66049]: 0 [Endpoint 0] 19:41:21.983 CNTRLR [Node 019] [+] [Meter] interviewComplete: true [Endpoint 0] [internal] 19:41:21.979 DRIVER ACK already received, resolving transaction 19:41:21.980 DRIVER resuming send queue 19:41:21.993 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 72 └─[ConfigurationCCGet] payload: 0x3d 19:41:22.075 SERIAL « [ACK] (0x06) 19:41:22.089 DRIVER ACK received from controller for current transaction 19:41:22.129 CNTRLR [Node 019] MultilevelSensorCC: doing a complete interview... 19:41:22.091 SERIAL « 0x060104011301e8 (7 bytes) 19:41:22.093 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:22.104 SERIAL » [ACK] (0x06) 19:41:22.108 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:22.106 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:22.131 CNTRLR » [Node 019] querying current sensor reading... 19:41:22.144 SERIAL « 0x0107001348000002a1 (9 bytes) 19:41:22.145 SERIAL Buffer := 0x0107001348000002a1 (9 bytes) 19:41:22.147 SERIAL » [ACK] (0x06) 19:41:22.152 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:22.148 DRIVER « [REQ] [SendData] [confirmation] callbackId: 72 transmitStatus: OK 19:41:22.150 DRIVER ACK received from node for current transaction. RTT = 158.15 ms 19:41:22.155 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:22.166 CNTRLR [Node 014] [+] [Configuration] 61: 1 19:41:22.180 CNTRLR » [Node 014] querying parameter #62 value... 19:41:22.158 SERIAL « 0x010b0004000e0570063d0101b0 (13 bytes) 19:41:22.161 SERIAL Buffer := 0x010b0004000e0570063d0101b0 (13 bytes) 19:41:22.171 SERIAL » [ACK] (0x06) 19:41:22.177 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:22.188 SERIAL » 0x01090013130231042549ad (11 bytes) 19:41:22.173 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x3d0101 19:41:22.175 DRIVER ACK already received, resolving transaction 19:41:22.176 DRIVER resuming send queue 19:41:22.187 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 73 └─[MultilevelSensorCCGet] 19:41:22.189 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:22.195 SERIAL « [ACK] (0x06) 19:41:22.197 DRIVER ACK received from controller for current transaction 19:41:22.198 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:22.204 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:22.200 SERIAL « 0x0104011301e8 (6 bytes) 19:41:22.201 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:22.202 SERIAL » [ACK] (0x06) 19:41:22.206 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:22.218 SERIAL « 0x0107001349000003a1 (9 bytes) 19:41:22.222 DRIVER « [REQ] [SendData] [confirmation] callbackId: 73 transmitStatus: OK 19:41:22.219 SERIAL Buffer := 0x0107001349000003a1 (9 bytes) 19:41:22.221 SERIAL » [ACK] (0x06) 19:41:22.226 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:22.224 DRIVER ACK received from node for current transaction. RTT = 38.86 ms 19:41:22.230 SERIAL « 0x010c0004001306310504220018e8 (14 bytes) 19:41:22.240 CNTRLR [Node 019] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 19:41:22.255 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[MultilevelSensorCCReport] payload: 0x04220018 19:41:22.231 SERIAL Buffer := 0x010c0004001306310504220018e8 (14 bytes) 19:41:22.251 SERIAL » [ACK] (0x06) 19:41:22.259 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:22.270 SERIAL » 0x010a00130e0370053e254acf (12 bytes) 19:41:22.246 CNTRLR [Node 019] [+] [Multilevel Sensor] Power: 2.4 [Endpoint 0] 19:41:22.262 CNTRLR « [Node 019] received current sensor reading: sensor type: Power value: 2.4 W 19:41:22.265 CNTRLR [Node 019] [+] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true 19:41:22.256 DRIVER ACK already received, resolving transaction 19:41:22.258 DRIVER resuming send queue 19:41:22.269 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 74 └─[ConfigurationCCGet] payload: 0x3e 19:41:22.356 SERIAL « [ACK] (0x06) 19:41:22.359 DRIVER ACK received from controller for current transaction 19:41:22.360 SERIAL « 0x060104011301e8 (7 bytes) 19:41:22.361 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:22.362 SERIAL » [ACK] (0x06) 19:41:22.364 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:22.363 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:22.366 SERIAL « 0x010700134a000002a3 (9 bytes) 19:41:22.367 SERIAL Buffer := 0x010700134a000002a3 (9 bytes) 19:41:22.369 SERIAL » [ACK] (0x06) 19:41:22.374 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:22.371 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 19:41:22.372 DRIVER ACK received from node for current transaction. RTT = 103.96 ms 19:41:22.384 CNTRLR [Node 014] [+] [Configuration] 62: 8 19:41:22.377 SERIAL « 0x010b0004000e0570063e0108ba (13 bytes) 19:41:22.379 SERIAL Buffer := 0x010b0004000e0570063e0108ba (13 bytes) 19:41:22.391 SERIAL » [ACK] (0x06) 19:41:22.403 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:22.411 SERIAL » 0x010a00130e0370053f254bcf (12 bytes) 19:41:22.393 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x3e0108 19:41:22.394 DRIVER ACK already received, resolving transaction 19:41:22.395 DRIVER resuming send queue 19:41:22.409 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 75 └─[ConfigurationCCGet] payload: 0x3f 19:41:22.412 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:22.405 CNTRLR » [Node 014] querying parameter #63 value... 19:41:22.492 CNTRLR [Node 019] MultiChannelAssociationCC: doing a complete interview... 19:41:22.505 SERIAL « [ACK] (0x06) 19:41:22.507 DRIVER ACK received from controller for current transaction 19:41:22.494 CNTRLR » [Node 019] querying number of association groups... 19:41:22.522 SERIAL « 0x060104011301e8 (7 bytes) 19:41:22.524 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:22.532 SERIAL » [ACK] (0x06) 19:41:22.536 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:22.534 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:22.557 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:22.582 SERIAL « 0x010700134b000002a2 (9 bytes) 19:41:22.583 SERIAL Buffer := 0x010700134b000002a2 (9 bytes) 19:41:22.585 SERIAL » [ACK] (0x06) 19:41:22.608 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:22.587 DRIVER « [REQ] [SendData] [confirmation] callbackId: 75 transmitStatus: OK 19:41:22.606 DRIVER ACK received from node for current transaction. RTT = 197.76 ms 19:41:22.654 CNTRLR [Node 014] [+] [Configuration] 63: 1 19:41:22.647 SERIAL « 0x010b0004000e0570063f0101b2 (13 bytes) 19:41:22.648 SERIAL Buffer := 0x010b0004000e0570063f0101b2 (13 bytes) 19:41:22.660 SERIAL » [ACK] (0x06) 19:41:22.667 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:22.689 SERIAL » 0x0109001313028e05254c16 (11 bytes) 19:41:22.662 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x3f0101 19:41:22.664 DRIVER ACK already received, resolving transaction 19:41:22.665 DRIVER resuming send queue 19:41:22.688 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 76 └─[MultiChannelAssociationCCSupportedGroupingsGet] 19:41:22.691 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:22.668 CNTRLR » [Node 014] querying parameter #70 value... 19:41:22.707 SERIAL « [ACK] (0x06) 19:41:22.708 DRIVER ACK received from controller for current transaction 19:41:22.709 SERIAL « 0x060104011301e8 (7 bytes) 19:41:22.710 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:22.711 SERIAL » [ACK] (0x06) 19:41:22.714 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:22.712 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:22.728 SERIAL « 0x010700134c000002a5 (9 bytes) 19:41:22.731 DRIVER « [REQ] [SendData] [confirmation] callbackId: 76 transmitStatus: OK 19:41:22.729 SERIAL Buffer := 0x010700134c000002a5 (9 bytes) 19:41:22.730 SERIAL » [ACK] (0x06) 19:41:22.735 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:22.733 DRIVER ACK received from node for current transaction. RTT = 45.61 ms 19:41:22.746 SERIAL « 0x010900040013038e060268 (11 bytes) 19:41:22.754 CNTRLR [Node 019] [+] [Multi Channel Association] groupCount: [Endpoint 0] [internal] 2 19:41:22.758 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCSupportedGroupingsReport] payload: 0x02 19:41:22.747 SERIAL Buffer := 0x010900040013038e060268 (11 bytes) 19:41:22.755 SERIAL » [ACK] (0x06) 19:41:22.762 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:22.774 SERIAL » 0x010a00130e03700546254db0 (12 bytes) 19:41:22.763 CNTRLR « [Node 019] supports 2 association groups 19:41:22.764 CNTRLR » [Node 019] querying association group #1... 19:41:22.759 DRIVER ACK already received, resolving transaction 19:41:22.760 DRIVER resuming send queue 19:41:22.773 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 77 └─[ConfigurationCCGet] payload: 0x46 19:41:22.775 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:22.800 SERIAL « [ACK] (0x06) 19:41:22.801 DRIVER ACK received from controller for current transaction 19:41:22.802 SERIAL « 0x060104011301e8 (7 bytes) 19:41:22.803 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:22.804 SERIAL » [ACK] (0x06) 19:41:22.806 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:22.804 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:22.824 SERIAL « 0x010700134d000002a4 (9 bytes) 19:41:22.828 DRIVER « [REQ] [SendData] [confirmation] callbackId: 77 transmitStatus: OK 19:41:22.825 SERIAL Buffer := 0x010700134d000002a4 (9 bytes) 19:41:22.826 SERIAL » [ACK] (0x06) 19:41:22.831 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:22.829 DRIVER ACK received from node for current transaction. RTT = 57.83 ms 19:41:22.840 CNTRLR [Node 014] [+] [Configuration] 70: 65535 19:41:22.834 SERIAL « 0x010c0004000e0670064602ffffcd (14 bytes) 19:41:22.835 SERIAL Buffer := 0x010c0004000e0670064602ffffcd (14 bytes) 19:41:22.844 SERIAL » [ACK] (0x06) 19:41:22.850 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:22.859 SERIAL » 0x010a001313038e0201254e10 (12 bytes) 19:41:22.846 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x4602ffff 19:41:22.848 DRIVER ACK already received, resolving transaction 19:41:22.849 DRIVER resuming send queue 19:41:22.859 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 78 └─[MultiChannelAssociationCCGet] payload: 0x01 19:41:22.852 CNTRLR [Node 014] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 19:41:22.937 SERIAL « [ACK] (0x06) 19:41:22.940 DRIVER ACK received from controller for current transaction 19:41:22.941 SERIAL « 0x060104011301e8 (7 bytes) 19:41:22.943 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:22.944 SERIAL » [ACK] (0x06) 19:41:22.948 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:22.946 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:22.964 CNTRLR [Node 014] AssociationCC: skipping interview because Multi Channel Association is supported... 19:41:22.952 SERIAL « 0x010700134e000002a7 (9 bytes) 19:41:22.953 SERIAL Buffer := 0x010700134e000002a7 (9 bytes) 19:41:22.954 SERIAL » [ACK] (0x06) 19:41:22.957 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:22.955 DRIVER « [REQ] [SendData] [confirmation] callbackId: 78 transmitStatus: OK 19:41:22.956 DRIVER ACK received from node for current transaction. RTT = 99.49 ms 19:41:22.966 CNTRLR [Node 014] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 19:41:22.969 CNTRLR [Node 014] BinarySwitchCC: doing a complete interview... 19:41:22.970 CNTRLR » [Node 014] querying Binary Switch state... 19:41:22.991 CNTRLR « [Node 019] received information for association group #1: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 19:41:22.992 CNTRLR » [Node 019] querying association group #2... 19:41:22.974 SERIAL « 0x010c00040013068e03010500016a (14 bytes) 19:41:22.976 SERIAL Buffer := 0x010c00040013068e03010500016a (14 bytes) 19:41:22.984 SERIAL » [ACK] (0x06) 19:41:22.989 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:23.001 SERIAL » 0x010900130e022502254fa4 (11 bytes) 19:41:22.986 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] payload: 0x01050001 19:41:22.987 DRIVER ACK already received, resolving transaction 19:41:22.988 DRIVER resuming send queue 19:41:22.998 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 79 └─[BinarySwitchCCGet] 19:41:23.003 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:23.004 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:23.013 SERIAL « [ACK] (0x06) 19:41:23.015 DRIVER ACK received from controller for current transaction 19:41:23.016 SERIAL « 0x060104011301e8 (7 bytes) 19:41:23.016 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:23.017 SERIAL » [ACK] (0x06) 19:41:23.019 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:23.018 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:23.031 SERIAL « 0x010700134f000002a6 (9 bytes) 19:41:23.034 DRIVER « [REQ] [SendData] [confirmation] callbackId: 79 transmitStatus: OK 19:41:23.032 SERIAL Buffer := 0x010700134f000002a6 (9 bytes) 19:41:23.033 SERIAL » [ACK] (0x06) 19:41:23.036 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:23.035 DRIVER ACK received from node for current transaction. RTT = 37.53 ms 19:41:23.041 SERIAL « 0x01090004000e032503ff26 (11 bytes) 19:41:23.045 CNTRLR [Node 014] [+] [Binary Switch] currentValue: true [Endpoint 0] 19:41:23.050 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[BinarySwitchCCReport] payload: 0xff 19:41:23.042 SERIAL Buffer := 0x01090004000e032503ff26 (11 bytes) 19:41:23.049 SERIAL » [ACK] (0x06) 19:41:23.053 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:23.064 SERIAL » 0x010a001313038e020225500d (12 bytes) 19:41:23.054 CNTRLR « [Node 014] received Binary Switch state: current value: true 19:41:23.056 CNTRLR [Node 014] [+] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] 19:41:23.057 CNTRLR [Node 014] MeterCC: doing a complete interview... 19:41:23.058 CNTRLR » [Node 014] querying meter support... 19:41:23.051 DRIVER ACK already received, resolving transaction 19:41:23.052 DRIVER resuming send queue 19:41:23.063 DRIVER » [Node 019] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 80 └─[MultiChannelAssociationCCGet] payload: 0x02 19:41:23.065 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:23.079 SERIAL « [ACK] (0x06) 19:41:23.085 DRIVER ACK received from controller for current transaction 19:41:23.086 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:23.095 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:23.092 SERIAL « 0x0104011301e8 (6 bytes) 19:41:23.093 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:23.094 SERIAL » [ACK] (0x06) 19:41:23.096 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:23.106 SERIAL « 0x0107001350000002b9 (9 bytes) 19:41:23.110 DRIVER « [REQ] [SendData] [confirmation] callbackId: 80 transmitStatus: OK 19:41:23.108 SERIAL Buffer := 0x0107001350000002b9 (9 bytes) 19:41:23.109 SERIAL » [ACK] (0x06) 19:41:23.112 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:23.111 DRIVER ACK received from node for current transaction. RTT = 49.14 ms 19:41:23.119 SERIAL « 0x010b00040013058e030205006c (13 bytes) 19:41:23.126 DRIVER « [Node 019] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] payload: 0x020500 19:41:23.134 CNTRLR « [Node 019] received information for association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 19:41:23.121 SERIAL Buffer := 0x010b00040013058e030205006c (13 bytes) 19:41:23.124 SERIAL » [ACK] (0x06) 19:41:23.132 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:23.156 SERIAL » 0x01070080130000006b (9 bytes) 19:41:23.127 DRIVER ACK already received, resolving transaction 19:41:23.130 DRIVER resuming send queue 19:41:23.154 DRIVER » [Node 019] [REQ] [GetRoutingInfo] [P: Controller] removeNonRepeaters: false removeBadLinks: false 19:41:23.159 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:23.139 CNTRLR [Node 019] [+] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true 19:41:23.143 CNTRLR [Node 019] Interview stage completed: CommandClasses 19:41:23.145 CNTRLR [Node 019] Interview stage completed: OverwriteConfig 19:41:23.147 CNTRLR » [Node 019] requesting node neighbors... 19:41:23.260 SERIAL « [ACK] (0x06) 19:41:23.263 DRIVER ACK received from controller for current transaction 19:41:23.271 CNTRLR « [Node 019] node neighbors received: 1, 14, 15, 16, 17, 18, 20, 21, 23, 30, 3 1, 33, 34, 35, 36, 37, 38, 41, 48 19:41:23.264 SERIAL « 0x060120018001e05b603f810000000000000000000000000000000000000000000 (35 bytes) 0003a 19:41:23.265 SERIAL Buffer := 0x0120018001e05b603f8100000000000000000000000000000000000 (34 bytes) 000000000003a 19:41:23.267 SERIAL » [ACK] (0x06) 19:41:23.272 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:23.288 SERIAL » 0x010900130e0232032551ac (11 bytes) 19:41:23.268 DRIVER « [RES] [GetRoutingInfo] [final] node ids: 1, 14, 15, 16, 17, 18, 20, 21, 23, 30, 31, 33, 34, 35, 36, 37, 38, 41, 48 19:41:23.269 DRIVER ACK already received, resolving transaction 19:41:23.270 DRIVER resuming send queue 19:41:23.287 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 81 └─[MeterCCSupportedGet] 19:41:23.273 CNTRLR [Node 019] Interview stage completed: Neighbors 19:41:23.273 CNTRLR [Node 019] Interview completed 19:41:23.274 CNTRLR [Node 019] The node is ready to be used 19:41:23.282 CNTRLR [Node 019] node is ready 19:41:23.301 SERIAL « [ACK] (0x06) 19:41:23.303 DRIVER ACK received from controller for current transaction 19:41:23.304 SERIAL « 0x060104011301e8 (7 bytes) 19:41:23.305 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:23.307 SERIAL » [ACK] (0x06) 19:41:23.310 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:23.309 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:23.322 SERIAL « 0x0107001351000003b9 (9 bytes) 19:41:23.323 SERIAL Buffer := 0x0107001351000003b9 (9 bytes) 19:41:23.324 SERIAL » [ACK] (0x06) 19:41:23.328 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:23.326 DRIVER « [REQ] [SendData] [confirmation] callbackId: 81 transmitStatus: OK 19:41:23.327 DRIVER ACK received from node for current transaction. RTT = 40.06 ms 19:41:23.346 CNTRLR « [Node 014] received meter support: type: Electric supported scales: · kWh, · W supported rate types: supports reset: true 19:41:23.336 SERIAL « 0x010a0004000e043204810549 (12 bytes) 19:41:23.337 SERIAL Buffer := 0x010a0004000e043204810549 (12 bytes) 19:41:23.340 SERIAL » [ACK] (0x06) 19:41:23.344 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:23.354 SERIAL » 0x010a00130e033201002552af (12 bytes) 19:41:23.341 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[MeterCCSupportedReport] payload: 0x8105 19:41:23.342 DRIVER ACK already received, resolving transaction 19:41:23.343 DRIVER resuming send queue 19:41:23.354 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 82 └─[MeterCCGet] payload: 0x00 19:41:23.356 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:23.347 CNTRLR » [Node 014] querying meter value (type = Electric, scale = kWh)... 19:41:23.360 SERIAL « [ACK] (0x06) 19:41:23.361 DRIVER ACK received from controller for current transaction 19:41:23.362 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:23.365 SERIAL « 0x0104011301e8 (6 bytes) 19:41:23.368 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:23.366 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:23.367 SERIAL » [ACK] (0x06) 19:41:23.369 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:23.383 SERIAL « 0x0107001352000002bb (9 bytes) 19:41:23.393 DRIVER « [REQ] [SendData] [confirmation] callbackId: 82 transmitStatus: OK 19:41:23.385 SERIAL Buffer := 0x0107001352000002bb (9 bytes) 19:41:23.391 SERIAL » [ACK] (0x06) 19:41:23.396 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:23.394 DRIVER ACK received from node for current transaction. RTT = 42.04 ms 19:41:23.398 SERIAL « 0x01100004000e0a32022144 (11 bytes) 19:41:23.399 SERIAL [incomplete] Buffer := 0x01100004000e0a32022144 (11 bytes) 19:41:23.456 CNTRLR [Node 014] [Meter] value[65537]: metadata updated [Endpoint 0] 19:41:23.481 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[MeterCCReport] payload: 0x21440000045a0000 19:41:23.450 SERIAL « 0x0000045a0000e4 (7 bytes) 19:41:23.451 SERIAL Buffer := 0x01100004000e0a320221440000045a0000e4 (18 bytes) 19:41:23.480 SERIAL » [ACK] (0x06) 19:41:23.484 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:23.491 SERIAL » 0x010a00130e033201102553be (12 bytes) 19:41:23.461 CNTRLR [Node 014] [+] [Meter] value[65537]: 11.14 [Endpoint 0] 19:41:23.471 CNTRLR [Node 014] [Meter] deltaTime[65537]: metadata updated [Endpoint 0] 19:41:23.476 CNTRLR [Node 014] [+] [Meter] deltaTime[65537]: 0 [Endpoint 0] 19:41:23.485 CNTRLR » [Node 014] querying meter value (type = Electric, scale = W)... 19:41:23.482 DRIVER ACK already received, resolving transaction 19:41:23.483 DRIVER resuming send queue 19:41:23.490 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 83 └─[MeterCCGet] payload: 0x10 19:41:23.492 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:23.503 SERIAL « [ACK] (0x06) 19:41:23.504 DRIVER ACK received from controller for current transaction 19:41:23.505 SERIAL « 0x060104011301e8 (7 bytes) 19:41:23.506 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:23.507 SERIAL » [ACK] (0x06) 19:41:23.510 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:23.509 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:23.524 SERIAL « 0x0107001353000002ba (9 bytes) 19:41:23.534 DRIVER « [REQ] [SendData] [confirmation] callbackId: 83 transmitStatus: OK 19:41:23.528 SERIAL Buffer := 0x0107001353000002ba (9 bytes) 19:41:23.530 SERIAL » [ACK] (0x06) 19:41:23.540 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:23.538 DRIVER ACK received from node for current transaction. RTT = 49.20 ms 19:41:23.549 CNTRLR [Node 014] [Meter] value[66049]: metadata updated [Endpoint 0] 19:41:23.544 SERIAL « 0x010e0004000e083202213200350000e5 (16 bytes) 19:41:23.545 SERIAL Buffer := 0x010e0004000e083202213200350000e5 (16 bytes) 19:41:23.567 SERIAL » [ACK] (0x06) 19:41:23.571 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:23.587 SERIAL » 0x0104006030ab (6 bytes) 19:41:23.568 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[MeterCCReport] payload: 0x213200350000 19:41:23.569 DRIVER ACK already received, resolving transaction 19:41:23.570 DRIVER resuming send queue 19:41:23.586 DRIVER » [Node 048] [REQ] [RequestNodeInfo] [P: NodeQuery] payload: 0x30 19:41:23.554 CNTRLR [Node 014] [+] [Meter] value[66049]: 5.3 [Endpoint 0] 19:41:23.559 CNTRLR [Node 014] [Meter] deltaTime[66049]: metadata updated [Endpoint 0] 19:41:23.563 CNTRLR [Node 014] [+] [Meter] deltaTime[66049]: 0 [Endpoint 0] 19:41:23.573 CNTRLR [Node 014] [+] [Meter] interviewComplete: true [Endpoint 0] [internal] 19:41:23.742 SERIAL « [ACK] (0x06) 19:41:23.746 DRIVER ACK received from controller for current transaction 19:41:23.747 SERIAL « 0x0601040160019b (7 bytes) 19:41:23.748 SERIAL Buffer := 0x01040160019b (6 bytes) 19:41:23.752 SERIAL » [ACK] (0x06) 19:41:23.758 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:23.754 DRIVER « [RES] [RequestNodeInfo] [confirmation] payload: 0x01 19:41:23.769 CNTRLR [Node 014] MultilevelSensorCC: doing a complete interview... 19:41:23.776 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:23.771 CNTRLR » [Node 014] querying current sensor reading... 19:41:23.903 SERIAL « 0x011700498430110411065e559f (13 bytes) 19:41:23.904 SERIAL [incomplete] Buffer := 0x011700498430110411065e559f (13 bytes) 19:41:23.909 DRIVER « [Node 048] [REQ] [ApplicationUpdateRequest] [final] payload: 0x8430110411065e559f7386858e59725a2625706c 19:41:23.910 CNTRLR [Node 048] The node is now awake. 19:41:23.906 SERIAL « 0x7386858e59725a2625706c13 (12 bytes) 19:41:23.907 SERIAL Buffer := 0x011700498430110411065e559f7386858e59725a2625706c13 (25 bytes) 19:41:23.908 SERIAL » [ACK] (0x06) 19:41:23.922 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:23.925 SERIAL » 0x010900130e0231042554ad (11 bytes) 19:41:23.918 DRIVER ACK already received, resolving transaction 19:41:23.919 DRIVER resuming send queue 19:41:23.924 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 84 └─[MultilevelSensorCCGet] 19:41:23.926 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:23.921 CNTRLR « [Node 048] node info received supported CCs: · Z-Wave Plus Info · Transport Service · Security 2 · Powerlevel · Version · Association · Multi Channel Association · Association Group Information · Manufacturer Specific · Device Reset Locally · Multilevel Switch · Binary Switch · Configuration · Supervision controlled CCs: 19:41:24.015 SERIAL « [ACK] (0x06) 19:41:24.017 DRIVER ACK received from controller for current transaction 19:41:24.018 SERIAL « 0x060104011301e8 (7 bytes) 19:41:24.018 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:24.019 SERIAL » [ACK] (0x06) 19:41:24.021 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:24.020 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:24.033 CNTRLR [Node 048] Interview stage completed: NodeInfo 19:41:24.027 SERIAL « 0x0107001354000002 (8 bytes) 19:41:24.028 SERIAL [incomplete] Buffer := 0x0107001354000002 (8 bytes) 19:41:24.044 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:24.041 CNTRLR [Node 048] ManufacturerSpecificCC: doing a complete interview... 19:41:24.042 CNTRLR » [Node 048] querying manufacturer information... 19:41:24.046 SERIAL « 0xbd (1 bytes) 19:41:24.047 SERIAL Buffer := 0x0107001354000002bd (9 bytes) 19:41:24.047 SERIAL » [ACK] (0x06) 19:41:24.051 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:24.049 DRIVER « [REQ] [SendData] [confirmation] callbackId: 84 transmitStatus: OK 19:41:24.049 DRIVER ACK received from node for current transaction. RTT = 125.91 ms 19:41:24.063 SERIAL « 0x010c0004000e06310504220035d8 (14 bytes) 19:41:24.070 CNTRLR [Node 014] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 19:41:24.081 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[MultilevelSensorCCReport] payload: 0x04220035 19:41:24.064 SERIAL Buffer := 0x010c0004000e06310504220035d8 (14 bytes) 19:41:24.079 SERIAL » [ACK] (0x06) 19:41:24.084 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:24.095 SERIAL » 0x010900130e028e05255512 (11 bytes) 19:41:24.076 CNTRLR [Node 014] [+] [Multilevel Sensor] Power: 5.3 [Endpoint 0] 19:41:24.085 CNTRLR « [Node 014] received current sensor reading: sensor type: Power value: 5.3 W 19:41:24.087 CNTRLR [Node 014] [+] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true 19:41:24.089 CNTRLR [Node 014] MultiChannelAssociationCC: doing a complete interview... 19:41:24.090 CNTRLR » [Node 014] querying number of association groups... 19:41:24.082 DRIVER ACK already received, resolving transaction 19:41:24.083 DRIVER resuming send queue 19:41:24.094 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 85 └─[MultiChannelAssociationCCSupportedGroupingsGet] 19:41:24.096 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:24.195 SERIAL « 0x011700498430110411065e559f7386858e59725a2625706c1318 (26 bytes) 19:41:24.202 CNTRLR « [Node 048] Received updated node info 19:41:24.208 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 19:41:24.198 SERIAL Buffer := 0x011700498430110411065e559f7386858e59725a2625706c1318 (26 bytes) 19:41:24.200 SERIAL » [ACK] (0x06) 19:41:24.205 SERIAL « [CAN] (0x18) 19:41:24.209 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:24.329 DRIVER » [Node 014] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 85 └─[MultiChannelAssociationCCSupportedGroupingsGet] 19:41:24.344 SERIAL » 0x010900130e028e05255512 (11 bytes) 19:41:24.360 SERIAL « [ACK] (0x06) 19:41:24.361 DRIVER ACK received from controller for current transaction 19:41:24.369 SERIAL « 0x060104011301e8 (7 bytes) 19:41:24.370 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:24.371 SERIAL » [ACK] (0x06) 19:41:24.374 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:24.372 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:24.383 SERIAL « 0x0107001355000002bc (9 bytes) 19:41:24.387 DRIVER « [REQ] [SendData] [confirmation] callbackId: 85 transmitStatus: OK 19:41:24.384 SERIAL Buffer := 0x0107001355000002bc (9 bytes) 19:41:24.385 SERIAL » [ACK] (0x06) 19:41:24.390 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:24.388 DRIVER ACK received from node for current transaction. RTT = 60.73 ms 19:41:24.400 CNTRLR [Node 014] [+] [Multi Channel Association] groupCount: [Endpoint 0] [internal] 2 19:41:24.394 SERIAL « 0x01090004000e038e060275 (11 bytes) 19:41:24.395 SERIAL Buffer := 0x01090004000e038e060275 (11 bytes) 19:41:24.402 SERIAL » [ACK] (0x06) 19:41:24.407 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:24.420 SERIAL » 0x010a00130e038e0201255615 (12 bytes) 19:41:24.404 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCSupportedGroupingsReport] payload: 0x02 19:41:24.405 DRIVER ACK already received, resolving transaction 19:41:24.406 DRIVER resuming send queue 19:41:24.419 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 86 └─[MultiChannelAssociationCCGet] payload: 0x01 19:41:24.422 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:24.409 CNTRLR « [Node 014] supports 2 association groups 19:41:24.410 CNTRLR » [Node 014] querying association group #1... 19:41:24.436 SERIAL « [ACK] (0x06) 19:41:24.441 DRIVER ACK received from controller for current transaction 19:41:24.443 SERIAL « 0x060104011301e8 (7 bytes) 19:41:24.443 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:24.444 SERIAL » [ACK] (0x06) 19:41:24.447 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:24.445 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:24.456 SERIAL « 0x0107001356000002bf (9 bytes) 19:41:24.461 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 19:41:24.457 SERIAL Buffer := 0x0107001356000002bf (9 bytes) 19:41:24.459 SERIAL » [ACK] (0x06) 19:41:24.464 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:24.462 DRIVER ACK received from node for current transaction. RTT = 48.97 ms 19:41:24.472 SERIAL « 0x01100004000e0a8e03010500010306071174 (18 bytes) 19:41:24.476 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] payload: 0x0105000103060711 19:41:24.479 CNTRLR « [Node 014] received information for association group #1: maximum # of nodes: 5 currently assigned nodes: 1, 3, 6, 7, 17 currently assigned endpoints: 19:41:24.473 SERIAL Buffer := 0x01100004000e0a8e03010500010306071174 (18 bytes) 19:41:24.475 SERIAL » [ACK] (0x06) 19:41:24.478 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:24.487 SERIAL » 0x010a00130e038e0202255717 (12 bytes) 19:41:24.477 DRIVER ACK already received, resolving transaction 19:41:24.477 DRIVER resuming send queue 19:41:24.485 DRIVER » [Node 014] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 87 └─[MultiChannelAssociationCCGet] payload: 0x02 19:41:24.490 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:24.480 CNTRLR » [Node 014] querying association group #2... 19:41:24.501 SERIAL « [ACK] (0x06) 19:41:24.502 DRIVER ACK received from controller for current transaction 19:41:24.503 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:24.510 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:24.506 SERIAL « 0x0104011301e8 (6 bytes) 19:41:24.507 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:24.508 SERIAL » [ACK] (0x06) 19:41:24.512 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:24.522 SERIAL « 0x0107001357000002be (9 bytes) 19:41:24.527 DRIVER « [REQ] [SendData] [confirmation] callbackId: 87 transmitStatus: OK 19:41:24.523 SERIAL Buffer := 0x0107001357000002be (9 bytes) 19:41:24.525 SERIAL » [ACK] (0x06) 19:41:24.531 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:24.529 DRIVER ACK received from node for current transaction. RTT = 44.02 ms 19:41:24.545 CNTRLR « [Node 014] received information for association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 19:41:24.535 SERIAL « 0x010b0004000e058e0302050071 (13 bytes) 19:41:24.536 SERIAL Buffer := 0x010b0004000e058e0302050071 (13 bytes) 19:41:24.538 SERIAL » [ACK] (0x06) 19:41:24.544 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:24.555 SERIAL » 0x0109001315025e012558d0 (11 bytes) 19:41:24.540 DRIVER « [Node 014] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] payload: 0x020500 19:41:24.541 DRIVER ACK already received, resolving transaction 19:41:24.542 DRIVER resuming send queue 19:41:24.553 DRIVER » [Node 021] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 88 └─[ZWavePlusCCGet] 19:41:24.548 CNTRLR [Node 014] [+] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true 19:41:24.654 SERIAL « [ACK] (0x06) 19:41:24.655 DRIVER ACK received from controller for current transaction 19:41:24.662 CNTRLR [Node 014] Interview stage completed: CommandClasses 19:41:24.656 SERIAL « 0x060104011301e8 (7 bytes) 19:41:24.656 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:24.657 SERIAL » [ACK] (0x06) 19:41:24.659 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:24.658 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:24.663 CNTRLR [Node 014] Interview stage completed: OverwriteConfig 19:41:24.664 CNTRLR » [Node 014] requesting node neighbors... 19:41:24.670 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:24.673 SERIAL « 0x0107001358000002b1 (9 bytes) 19:41:24.677 DRIVER « [REQ] [SendData] [confirmation] callbackId: 88 transmitStatus: OK 19:41:24.674 SERIAL Buffer := 0x0107001358000002b1 (9 bytes) 19:41:24.675 SERIAL » [ACK] (0x06) 19:41:24.681 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:24.679 DRIVER ACK received from node for current transaction. RTT = 126.42 ms 19:41:24.683 SERIAL « 0x010f00040015095e020105001c001c (15 bytes) 19:41:24.684 SERIAL [incomplete] Buffer := 0x010f00040015095e020105001c001c (15 bytes) 19:41:24.697 CNTRLR [Node 021] [+] [Z-Wave Plus Info] zwavePlusVersion: 1 [Endpoint 0] 19:41:24.723 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[ZWavePlusCCReport] payload: 0x0105001c001c00 19:41:24.691 SERIAL « 0x00b0 (2 bytes) 19:41:24.692 SERIAL Buffer := 0x010f00040015095e020105001c001c00b0 (17 bytes) 19:41:24.721 SERIAL » [ACK] (0x06) 19:41:24.726 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:24.753 SERIAL » 0x010700800e00000076 (9 bytes) 19:41:24.703 CNTRLR [Node 021] [+] [Z-Wave Plus Info] nodeType: 0 [Endpoint 0] 19:41:24.708 CNTRLR [Node 021] [+] [Z-Wave Plus Info] roleType: 5 [Endpoint 0] 19:41:24.714 CNTRLR [Node 021] [+] [Z-Wave Plus Info] installerIcon: 7168 [Endpoint 0] 19:41:24.718 CNTRLR [Node 021] [+] [Z-Wave Plus Info] userIcon: 7168 [Endpoint 0] 19:41:24.727 CNTRLR « [Node 021] received response for Z-Wave+ information: Z-Wave+ version: 1 role type: AlwaysOnSlave node type: Node installer icon: 0x1c00 user icon: 0x1c00 19:41:24.731 CNTRLR [Node 021] [+] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue 19:41:24.742 CNTRLR [Node 021] BasicCC: doing a complete interview... 19:41:24.743 CNTRLR » [Node 021] querying Basic CC state... 19:41:24.724 DRIVER ACK already received, resolving transaction 19:41:24.725 DRIVER resuming send queue 19:41:24.751 DRIVER » [Node 014] [REQ] [GetRoutingInfo] [P: Controller] removeNonRepeaters: false removeBadLinks: false 19:41:24.758 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:24.773 SERIAL « [ACK] (0x06) 19:41:24.776 DRIVER ACK received from controller for current transaction 19:41:24.786 CNTRLR « [Node 014] node neighbors received: 1, 3, 15, 16, 17, 18, 19, 20, 21, 24, 30 , 31, 33, 34, 35, 36, 37, 39 19:41:24.777 SERIAL « 0x060120018005c09f605f000000000000000000000000000000000000000000000 (35 bytes) 0003b 19:41:24.778 SERIAL Buffer := 0x0120018005c09f605f0000000000000000000000000000000000000 (34 bytes) 000000000003b 19:41:24.780 SERIAL » [ACK] (0x06) 19:41:24.787 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:24.806 SERIAL » 0x01090013150220022559ac (11 bytes) 19:41:24.782 DRIVER « [RES] [GetRoutingInfo] [final] node ids: 1, 3, 15, 16, 17, 18, 19, 20, 21, 24, 30, 31, 33, 34, 35, 36, 37, 39 19:41:24.783 DRIVER ACK already received, resolving transaction 19:41:24.784 DRIVER resuming send queue 19:41:24.804 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 89 └─[BasicCCGet] 19:41:24.789 CNTRLR [Node 014] Interview stage completed: Neighbors 19:41:24.790 CNTRLR [Node 014] Interview completed 19:41:24.791 CNTRLR [Node 014] The node is ready to be used 19:41:24.797 CNTRLR [Node 014] node is ready 19:41:24.936 SERIAL « [ACK] (0x06) 19:41:24.937 DRIVER ACK received from controller for current transaction 19:41:24.939 SERIAL « 0x060104011301e8 (7 bytes) 19:41:24.939 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:24.940 SERIAL » [ACK] (0x06) 19:41:24.942 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:24.941 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:24.946 SERIAL « 0x0107001359000003 (8 bytes) 19:41:24.947 SERIAL [incomplete] Buffer := 0x0107001359000003 (8 bytes) 19:41:24.966 DRIVER « [REQ] [SendData] [confirmation] callbackId: 89 transmitStatus: OK 19:41:24.963 SERIAL « 0xb1 (1 bytes) 19:41:24.964 SERIAL Buffer := 0x0107001359000003b1 (9 bytes) 19:41:24.965 SERIAL » [ACK] (0x06) 19:41:24.969 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:24.967 DRIVER ACK received from node for current transaction. RTT = 164.41 ms 19:41:24.999 SERIAL « 0x01090004001503200363a4 (11 bytes) 19:41:25.011 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[BasicCCReport] payload: 0x63 19:41:25.019 CNTRLR « [Node 021] received Basic CC state: current value: 99 19:41:25.001 SERIAL Buffer := 0x01090004001503200363a4 (11 bytes) 19:41:25.008 SERIAL » [ACK] (0x06) 19:41:25.017 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:25.036 SERIAL » 0x0109001315022502255aaa (11 bytes) 19:41:25.014 DRIVER ACK already received, resolving transaction 19:41:25.016 DRIVER resuming send queue 19:41:25.034 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 90 └─[BinarySwitchCCGet] 19:41:25.037 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:25.022 CNTRLR [Node 021] [+] [Basic] interviewComplete: true [Endpoint 0] [internal] 19:41:25.024 CNTRLR [Node 021] BinarySwitchCC: doing a complete interview... 19:41:25.025 CNTRLR » [Node 021] querying Binary Switch state... 19:41:25.051 SERIAL « [ACK] (0x06) 19:41:25.053 DRIVER ACK received from controller for current transaction 19:41:25.054 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:25.059 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:25.056 SERIAL « 0x0104011301e8 (6 bytes) 19:41:25.057 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:25.058 SERIAL » [ACK] (0x06) 19:41:25.060 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:25.071 SERIAL « 0x010700135a000003b2 (9 bytes) 19:41:25.074 DRIVER « [REQ] [SendData] [confirmation] callbackId: 90 transmitStatus: OK 19:41:25.072 SERIAL Buffer := 0x010700135a000003b2 (9 bytes) 19:41:25.073 SERIAL » [ACK] (0x06) 19:41:25.076 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:25.075 DRIVER ACK received from node for current transaction. RTT = 41.72 ms 19:41:25.105 SERIAL « 0x010900040015032503ff3d (11 bytes) 19:41:25.110 CNTRLR [Node 021] [+] [Binary Switch] currentValue: true [Endpoint 0] 19:41:25.115 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[BinarySwitchCCReport] payload: 0xff 19:41:25.107 SERIAL Buffer := 0x010900040015032503ff3d (11 bytes) 19:41:25.114 SERIAL » [ACK] (0x06) 19:41:25.119 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:25.140 SERIAL » 0x0109001315022606255bac (11 bytes) 19:41:25.120 CNTRLR « [Node 021] received Binary Switch state: current value: true 19:41:25.122 CNTRLR [Node 021] [+] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] 19:41:25.126 CNTRLR [Node 021] MultilevelSwitchCC: doing a complete interview... 19:41:25.128 CNTRLR » [Node 021] requesting switch type... 19:41:25.117 DRIVER ACK already received, resolving transaction 19:41:25.117 DRIVER resuming send queue 19:41:25.138 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 91 └─[MultilevelSwitchCCSupportedGet] 19:41:25.142 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:25.279 SERIAL « [ACK] (0x06) 19:41:25.280 DRIVER ACK received from controller for current transaction 19:41:25.281 SERIAL « 0x060104011301e8 (7 bytes) 19:41:25.282 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:25.283 SERIAL » [ACK] (0x06) 19:41:25.284 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:25.283 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:25.301 SERIAL « 0x010700135b000002b2 (9 bytes) 19:41:25.305 DRIVER « [REQ] [SendData] [confirmation] callbackId: 91 transmitStatus: OK 19:41:25.302 SERIAL Buffer := 0x010700135b000002b2 (9 bytes) 19:41:25.303 SERIAL » [ACK] (0x06) 19:41:25.310 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:25.306 DRIVER ACK received from node for current transaction. RTT = 172.24 ms 19:41:25.317 SERIAL « 0x010a000400150426070200c3 (12 bytes) 19:41:25.324 CNTRLR [Node 021] [+] [Multilevel Switch] switchType: 2 [Endpoint 0] [internal] 19:41:25.337 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[MultilevelSwitchCCSupportedReport] payload: 0x0200 19:41:25.318 SERIAL Buffer := 0x010a000400150426070200c3 (12 bytes) 19:41:25.335 SERIAL » [ACK] (0x06) 19:41:25.340 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:25.347 SERIAL » 0x0109001315022602255caf (11 bytes) 19:41:25.327 CNTRLR [Node 021] [Multilevel Switch] Down: metadata updated [Endpoint 0] 19:41:25.332 CNTRLR [Node 021] [Multilevel Switch] Up: metadata updated [Endpoint 0] 19:41:25.340 CNTRLR « [Node 021] has switch type Down/Up 19:41:25.341 CNTRLR » [Node 021] requesting current switch state... 19:41:25.338 DRIVER ACK already received, resolving transaction 19:41:25.339 DRIVER resuming send queue 19:41:25.346 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 92 └─[MultilevelSwitchCCGet] 19:41:25.348 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:25.376 SERIAL « [ACK] (0x06) 19:41:25.378 DRIVER ACK received from controller for current transaction 19:41:25.380 SERIAL « 0x060104011301e8 (7 bytes) 19:41:25.381 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:25.382 SERIAL » [ACK] (0x06) 19:41:25.385 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:25.383 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:25.389 SERIAL « 0x010700135c000003b4 (9 bytes) 19:41:25.391 SERIAL Buffer := 0x010700135c000003b4 (9 bytes) 19:41:25.392 SERIAL » [ACK] (0x06) 19:41:25.396 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:25.393 DRIVER « [REQ] [SendData] [confirmation] callbackId: 92 transmitStatus: OK 19:41:25.394 DRIVER ACK received from node for current transaction. RTT = 48.56 ms 19:41:25.412 SERIAL « 0x01090004001503260363a2 (11 bytes) 19:41:25.421 CNTRLR [Node 021] [+] [Multilevel Switch] currentValue: 99 [Endpoint 0] 19:41:25.427 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[MultilevelSwitchCCReport] payload: 0x63 19:41:25.414 SERIAL Buffer := 0x01090004001503260363a2 (11 bytes) 19:41:25.425 SERIAL » [ACK] (0x06) 19:41:25.431 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:25.440 SERIAL » 0x0109001315023203255dbb (11 bytes) 19:41:25.433 CNTRLR [Node 021] [+] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true 19:41:25.435 CNTRLR [Node 021] MeterCC: doing a complete interview... 19:41:25.435 CNTRLR » [Node 021] querying meter support... 19:41:25.428 DRIVER ACK already received, resolving transaction 19:41:25.429 DRIVER resuming send queue 19:41:25.439 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 93 └─[MeterCCSupportedGet] 19:41:25.441 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:25.462 SERIAL « [ACK] (0x06) 19:41:25.464 DRIVER ACK received from controller for current transaction 19:41:25.465 SERIAL « 0x060104011301e8 (7 bytes) 19:41:25.466 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:25.467 SERIAL » [ACK] (0x06) 19:41:25.469 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:25.468 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:25.475 SERIAL « 0x010700135d000002b4 (9 bytes) 19:41:25.481 DRIVER « [REQ] [SendData] [confirmation] callbackId: 93 transmitStatus: OK 19:41:25.477 SERIAL Buffer := 0x010700135d000002b4 (9 bytes) 19:41:25.479 SERIAL » [ACK] (0x06) 19:41:25.492 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:25.483 DRIVER ACK received from node for current transaction. RTT = 44.09 ms 19:41:25.517 SERIAL « 0x010a00040015043204810552 (12 bytes) 19:41:25.522 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[MeterCCSupportedReport] payload: 0x8105 19:41:25.526 CNTRLR « [Node 021] received meter support: type: Electric supported scales: · kWh, · W supported rate types: supports reset: true 19:41:25.519 SERIAL Buffer := 0x010a00040015043204810552 (12 bytes) 19:41:25.521 SERIAL » [ACK] (0x06) 19:41:25.525 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:25.536 SERIAL » 0x010a00131503320100255eb8 (12 bytes) 19:41:25.523 DRIVER ACK already received, resolving transaction 19:41:25.524 DRIVER resuming send queue 19:41:25.535 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 94 └─[MeterCCGet] payload: 0x00 19:41:25.537 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:25.528 CNTRLR » [Node 021] querying meter value (type = Electric, scale = kWh)... 19:41:25.550 SERIAL « [ACK] (0x06) 19:41:25.551 DRIVER ACK received from controller for current transaction 19:41:25.552 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:25.560 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:25.555 SERIAL « 0x0104011301e8 (6 bytes) 19:41:25.557 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:25.558 SERIAL » [ACK] (0x06) 19:41:25.562 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:25.572 SERIAL « 0x010700135e000003b6 (9 bytes) 19:41:25.576 DRIVER « [REQ] [SendData] [confirmation] callbackId: 94 transmitStatus: OK 19:41:25.573 SERIAL Buffer := 0x010700135e000003b6 (9 bytes) 19:41:25.575 SERIAL » [ACK] (0x06) 19:41:25.580 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:25.577 DRIVER ACK received from node for current transaction. RTT = 43.64 ms 19:41:25.589 CNTRLR [Node 033] The node is now asleep. 19:41:25.588 DRIVER The awake timeout for node 33 has elapsed. Assuming it is asleep. 19:41:25.601 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:25.733 CNTRLR [Node 034] The node is now asleep. 19:41:25.732 DRIVER The awake timeout for node 34 has elapsed. Assuming it is asleep. 19:41:25.755 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:25.761 SERIAL « 0x0114000400150e3202212480000000000180000000c0 (22 bytes) 19:41:25.768 CNTRLR [Node 021] [Meter] value[65537]: metadata updated [Endpoint 0] 19:41:25.801 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[MeterCCReport] payload: 0x212480000000000180000000 19:41:25.802 DRIVER ACK already received, resolving transaction 19:41:25.802 DRIVER resuming send queue 19:41:25.809 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 95 └─[MeterCCGet] payload: 0x10 19:41:25.811 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:25.762 SERIAL Buffer := 0x0114000400150e3202212480000000000180000000c0 (22 bytes) 19:41:25.799 SERIAL » [ACK] (0x06) 19:41:25.803 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:25.810 SERIAL » 0x010a00131503320110255fa9 (12 bytes) 19:41:25.775 CNTRLR [Node 021] [+] [Meter] value[65537]: -214748364.8 [Endpoint 0] 19:41:25.781 CNTRLR [Node 021] [Meter] previousValue[65537]: metadata updated [Endpoint 0] 19:41:25.786 CNTRLR [Node 021] [+] [Meter] previousValue[65537]: -214748364.8 [Endpoint 0] 19:41:25.791 CNTRLR [Node 021] [Meter] deltaTime[65537]: metadata updated [Endpoint 0] 19:41:25.795 CNTRLR [Node 021] [+] [Meter] deltaTime[65537]: 1 [Endpoint 0] 19:41:25.804 CNTRLR » [Node 021] querying meter value (type = Electric, scale = W)... 19:41:25.840 DRIVER The awake timeout for node 35 has elapsed. Assuming it is asleep. 19:41:25.841 CNTRLR [Node 035] The node is now asleep. 19:41:25.861 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:25.864 SERIAL « [ACK] (0x06) 19:41:25.865 DRIVER ACK received from controller for current transaction 19:41:25.870 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:25.866 SERIAL « 0x060104011301e8 (7 bytes) 19:41:25.867 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:25.869 SERIAL » [ACK] (0x06) 19:41:25.872 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:25.901 SERIAL « 0x010700135f000003b7 (9 bytes) 19:41:25.907 DRIVER « [REQ] [SendData] [confirmation] callbackId: 95 transmitStatus: OK 19:41:25.938 CNTRLR [Node 036] The node is now asleep. 19:41:25.903 SERIAL Buffer := 0x010700135f000003b7 (9 bytes) 19:41:25.905 SERIAL » [ACK] (0x06) 19:41:25.912 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:25.910 DRIVER ACK received from node for current transaction. RTT = 101.59 ms 19:41:25.937 DRIVER The awake timeout for node 36 has elapsed. Assuming it is asleep. 19:41:25.962 CNTRLR [Node 021] [Meter] value[66049]: metadata updated [Endpoint 0] 19:41:25.969 CNTRLR [Node 021] [+] [Meter] value[66049]: 4 [Endpoint 0] 19:41:25.976 CNTRLR [Node 021] [Meter] deltaTime[66049]: metadata updated [Endpoint 0] 19:41:25.985 CNTRLR [Node 021] [+] [Meter] deltaTime[66049]: 0 [Endpoint 0] 19:41:26.000 CNTRLR [Node 021] [+] [Meter] interviewComplete: true [Endpoint 0] [internal] 19:41:25.954 SERIAL « 0x0110000400150a32022134000000280000f9 (18 bytes) 19:41:25.956 SERIAL Buffer := 0x0110000400150a32022134000000280000f9 (18 bytes) 19:41:25.991 SERIAL » [ACK] (0x06) 19:41:25.997 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:26.028 SERIAL » 0x01090013300272042560e4 (11 bytes) 19:41:25.993 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[MeterCCReport] payload: 0x2134000000280000 19:41:25.995 DRIVER ACK already received, resolving transaction 19:41:25.996 DRIVER resuming send queue 19:41:26.027 DRIVER » [Node 048] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 96 └─[ManufacturerSpecificCCGet] 19:41:26.030 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:26.167 DRIVER The awake timeout for node 37 has elapsed. Assuming it is asleep. 19:41:26.168 CNTRLR [Node 037] The node is now asleep. 19:41:26.181 SERIAL « [ACK] (0x06) 19:41:26.183 DRIVER ACK received from controller for current transaction 19:41:26.186 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:26.213 CNTRLR [Node 038] The node is now asleep. 19:41:26.184 SERIAL « 0x060104011301e8 (7 bytes) 19:41:26.185 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:26.185 SERIAL » [ACK] (0x06) 19:41:26.187 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:26.207 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:26.208 DRIVER The awake timeout for node 38 has elapsed. Assuming it is asleep. 19:41:26.249 CNTRLR [Node 039] The node is now asleep. 19:41:26.244 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:26.248 DRIVER The awake timeout for node 39 has elapsed. Assuming it is asleep. 19:41:26.268 CNTRLR [Node 021] ConfigurationCC: Loading configuration parameters from device confi g 19:41:26.273 CNTRLR [Node 021] [+] [Configuration] isParamInformationFromConfig: false [internal] 19:41:26.279 CNTRLR [Node 021] [Configuration] 1: metadata updated 19:41:26.285 CNTRLR [Node 021] [Configuration] 5: metadata updated 19:41:26.292 CNTRLR [Node 021] [Configuration] 10: metadata updated 19:41:26.298 CNTRLR [Node 021] [Configuration] 11: metadata updated 19:41:26.304 CNTRLR [Node 021] [Configuration] 12: metadata updated 19:41:26.311 CNTRLR [Node 021] [Configuration] 21: metadata updated 19:41:26.318 CNTRLR [Node 021] [Configuration] 30: metadata updated 19:41:26.325 CNTRLR [Node 021] [Configuration] 40: metadata updated 19:41:26.333 CNTRLR [Node 021] [Configuration] 42: metadata updated 19:41:26.339 CNTRLR [Node 021] [Configuration] 60: metadata updated 19:41:26.345 CNTRLR [Node 021] [Configuration] 61: metadata updated 19:41:26.353 CNTRLR [Node 021] [Configuration] 65: metadata updated 19:41:26.359 CNTRLR [Node 021] [Configuration] 66: metadata updated 19:41:26.365 CNTRLR [Node 021] [Configuration] 67: metadata updated 19:41:26.372 CNTRLR [Node 021] [Configuration] 68: metadata updated 19:41:26.379 CNTRLR [Node 021] [Configuration] 110: metadata updated 19:41:26.386 CNTRLR [Node 021] [Configuration] 120: metadata updated 19:41:26.392 CNTRLR [Node 021] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 19:41:26.394 CNTRLR » [Node 021] querying parameter #1 value... 19:41:26.440 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:26.443 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:26.449 DRIVER The awake timeout for node 41 has elapsed. Assuming it is asleep. 19:41:26.450 CNTRLR [Node 041] The node is now asleep. 19:41:26.490 SERIAL « 0x010700136000000289 (9 bytes) 19:41:26.510 DRIVER « [REQ] [SendData] [confirmation] callbackId: 96 transmitStatus: OK 19:41:26.512 DRIVER ACK received from node for current transaction. RTT = 485.74 ms 19:41:26.548 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:26.492 SERIAL Buffer := 0x010700136000000289 (9 bytes) 19:41:26.494 SERIAL » [ACK] (0x06) 19:41:26.529 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:26.577 CNTRLR [Node 048] [+] [Manufacturer Specific] manufacturerId: 600 [Endpoint 0] 19:41:26.605 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[ManufacturerSpecificCCReport] payload: 0x02580200102c 19:41:26.606 DRIVER ACK already received, resolving transaction 19:41:26.607 DRIVER resuming send queue 19:41:26.629 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 97 └─[ConfigurationCCGet] payload: 0x01 19:41:26.570 SERIAL « 0x010e0004003008720502580200102cde (16 bytes) 19:41:26.572 SERIAL Buffer := 0x010e0004003008720502580200102cde (16 bytes) 19:41:26.603 SERIAL » [ACK] (0x06) 19:41:26.609 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:26.630 SERIAL » 0x010a001315037005012561c0 (12 bytes) 19:41:26.589 CNTRLR [Node 048] [+] [Manufacturer Specific] productType: 512 [Endpoint 0] 19:41:26.596 CNTRLR [Node 048] [+] [Manufacturer Specific] productId: 4140 [Endpoint 0] 19:41:26.610 CNTRLR « [Node 048] received response for manufacturer information: manufacturer: Shenzhen Neo Electronics Co., Ltd. (0x0258) product type: 0x0200 product id: 0x102c 19:41:26.612 CNTRLR [Node 048] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 19:41:26.782 SERIAL « [ACK] (0x06) 19:41:26.784 DRIVER ACK received from controller for current transaction 19:41:26.784 SERIAL « 0x060104011301e8 (7 bytes) 19:41:26.785 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:26.786 SERIAL » [ACK] (0x06) 19:41:26.788 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:26.787 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:26.976 CNTRLR [Node 048] VersionCC: doing a complete interview... 19:41:26.982 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:26.977 CNTRLR » [Node 048] querying node versions... 19:41:26.985 SERIAL « 0x010700136100000288 (9 bytes) 19:41:26.990 DRIVER « [REQ] [SendData] [confirmation] callbackId: 97 transmitStatus: OK 19:41:26.992 DRIVER ACK received from node for current transaction. RTT = 364.13 ms 19:41:26.987 SERIAL Buffer := 0x010700136100000288 (9 bytes) 19:41:26.988 SERIAL » [ACK] (0x06) 19:41:26.994 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.016 CNTRLR [Node 021] [+] [Configuration] 1: 0 19:41:27.024 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x010100 19:41:27.025 DRIVER ACK already received, resolving transaction 19:41:27.026 DRIVER resuming send queue 19:41:27.005 SERIAL « 0x010b0004001505700601010096 (13 bytes) 19:41:27.006 SERIAL Buffer := 0x010b0004001505700601010096 (13 bytes) 19:41:27.022 SERIAL » [ACK] (0x06) 19:41:27.027 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.050 SERIAL » 0x0109001330028611256207 (11 bytes) 19:41:27.028 CNTRLR » [Node 021] querying parameter #5 value... 19:41:27.049 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 98 └─[VersionCCGet] 19:41:27.052 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:27.072 SERIAL « [ACK] (0x06) 19:41:27.073 DRIVER ACK received from controller for current transaction 19:41:27.075 SERIAL « 0x060104011301e8 (7 bytes) 19:41:27.076 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:27.078 SERIAL » [ACK] (0x06) 19:41:27.081 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.080 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:27.134 SERIAL « 0x010f00040030098612060601020110004b (17 bytes) 19:41:27.143 CNTRLR [Node 048] [+] [Version] libraryType: 6 [Endpoint 0] 19:41:27.169 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[VersionCCReport] payload: 0x06060102011000 19:41:27.136 SERIAL Buffer := 0x010f00040030098612060601020110004b (17 bytes) 19:41:27.167 SERIAL » [ACK] (0x06) 19:41:27.173 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.181 SERIAL » 0x010a001315037005052563c6 (12 bytes) 19:41:27.150 CNTRLR [Node 048] [+] [Version] protocolVersion: "6.1" [Endpoint 0] 19:41:27.163 CNTRLR [Node 048] [+] [Version] firmwareVersions: 2.1 [Endpoint 0] 19:41:27.174 CNTRLR « [Node 048] received response for node versions: library type: Routing Slave (0x06) protocol version: 6.1 firmware versions: 2.1 19:41:27.175 CNTRLR » [Node 048] querying CC versions... 19:41:27.175 CNTRLR » [Node 048] querying the CC version for Z-Wave Plus Info (0x5e)... 19:41:27.170 DRIVER ACK already received, resolving transaction 19:41:27.171 DRIVER resuming send queue 19:41:27.180 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 99 └─[ConfigurationCCGet] payload: 0x05 19:41:27.182 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:27.190 SERIAL « 0x010700136200000a83 (9 bytes) 19:41:27.191 SERIAL Buffer := 0x010700136200000a83 (9 bytes) 19:41:27.193 SERIAL » [ACK] (0x06) 19:41:27.196 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.194 DRIVER handling request SendData (19) 19:41:27.195 DRIVER no handlers registered! 19:41:27.214 SERIAL « [CAN] (0x18) 19:41:27.217 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.216 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 19:41:27.242 CNTRLR [Node 048] [~] [Version] libraryType: 6 => 6 [Endpoint 0] 19:41:27.234 SERIAL « 0x010f00040030098612060601020110004b (17 bytes) 19:41:27.235 SERIAL Buffer := 0x010f00040030098612060601020110004b (17 bytes) 19:41:27.258 SERIAL » [ACK] (0x06) 19:41:27.262 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.250 CNTRLR [Node 048] [~] [Version] protocolVersion: "6.1" => "6.1" [Endpoint 0] 19:41:27.255 CNTRLR [Node 048] [~] [Version] firmwareVersions: 2.1 => 2.1 [Endpoint 0] 19:41:27.322 DRIVER » [Node 021] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 99 └─[ConfigurationCCGet] payload: 0x05 19:41:27.323 SERIAL » 0x010a001315037005052563c6 (12 bytes) 19:41:27.360 SERIAL « [ACK] (0x06) 19:41:27.362 DRIVER ACK received from controller for current transaction 19:41:27.364 SERIAL « 0x060104011301e8 (7 bytes) 19:41:27.366 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:27.368 SERIAL » [ACK] (0x06) 19:41:27.373 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.370 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:27.400 SERIAL « 0x01070013630000028a (9 bytes) 19:41:27.406 DRIVER « [REQ] [SendData] [confirmation] callbackId: 99 transmitStatus: OK 19:41:27.402 SERIAL Buffer := 0x01070013630000028a (9 bytes) 19:41:27.403 SERIAL » [ACK] (0x06) 19:41:27.410 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.408 DRIVER ACK received from node for current transaction. RTT = 86.99 ms 19:41:27.419 CNTRLR [Node 021] [+] [Configuration] 5: 0 19:41:27.415 SERIAL « 0x010b0004001505700605010092 (13 bytes) 19:41:27.416 SERIAL Buffer := 0x010b0004001505700605010092 (13 bytes) 19:41:27.423 SERIAL » [ACK] (0x06) 19:41:27.428 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.457 SERIAL » 0x010a0013300386135e25645f (12 bytes) 19:41:27.425 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x050100 19:41:27.426 DRIVER ACK already received, resolving transaction 19:41:27.427 DRIVER resuming send queue 19:41:27.434 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 100 └─[VersionCCCommandClassGet] payload: 0x5e 19:41:27.459 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:27.429 CNTRLR » [Node 021] querying parameter #10 value... 19:41:27.480 SERIAL « [ACK] (0x06) 19:41:27.482 DRIVER ACK received from controller for current transaction 19:41:27.483 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.491 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:27.486 SERIAL « 0x0104011301e8 (6 bytes) 19:41:27.487 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:27.489 SERIAL » [ACK] (0x06) 19:41:27.493 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.498 SERIAL « 0x01070013640000028d (9 bytes) 19:41:27.503 DRIVER « [REQ] [SendData] [confirmation] callbackId: 100 transmitStatus: OK 19:41:27.500 SERIAL Buffer := 0x01070013640000028d (9 bytes) 19:41:27.501 SERIAL » [ACK] (0x06) 19:41:27.511 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.509 DRIVER ACK received from node for current transaction. RTT = 75.97 ms 19:41:27.516 SERIAL « 0x010a000400300486145e020b (12 bytes) 19:41:27.521 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x5e02 19:41:27.525 CNTRLR [Node 048] supports CC Z-Wave Plus Info (0x5e) in version 2 19:41:27.517 SERIAL Buffer := 0x010a000400300486145e020b (12 bytes) 19:41:27.519 SERIAL » [ACK] (0x06) 19:41:27.524 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.535 SERIAL » 0x010a0013150370050a2565cf (12 bytes) 19:41:27.522 DRIVER ACK already received, resolving transaction 19:41:27.523 DRIVER resuming send queue 19:41:27.534 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 101 └─[ConfigurationCCGet] payload: 0x0a 19:41:27.536 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:27.527 CNTRLR [Node 048] skipping query for Transport Service (0x55) because max implement ed version is 0 19:41:27.528 CNTRLR [Node 048] skipping query for Security 2 (0x9f) because max implemented vers ion is 0 19:41:27.529 CNTRLR [Node 048] skipping query for Powerlevel (0x73) because max implemented vers ion is 0 19:41:27.530 CNTRLR » [Node 048] querying the CC version for Version (0x86)... 19:41:27.541 SERIAL « [ACK] (0x06) 19:41:27.542 DRIVER ACK received from controller for current transaction 19:41:27.542 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.547 SERIAL « 0x0104011301e8 (6 bytes) 19:41:27.551 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:27.548 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:27.549 SERIAL » [ACK] (0x06) 19:41:27.552 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.567 SERIAL « 0x01070013650000038d (9 bytes) 19:41:27.571 DRIVER « [REQ] [SendData] [confirmation] callbackId: 101 transmitStatus: OK 19:41:27.569 SERIAL Buffer := 0x01070013650000038d (9 bytes) 19:41:27.570 SERIAL » [ACK] (0x06) 19:41:27.574 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.572 DRIVER ACK received from node for current transaction. RTT = 39.01 ms 19:41:27.610 SERIAL « 0x010c000400150670060a0200ff65 (14 bytes) 19:41:27.619 CNTRLR [Node 021] [+] [Configuration] 10: 255 19:41:27.629 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x0a0200ff 19:41:27.611 SERIAL Buffer := 0x010c000400150670060a0200ff65 (14 bytes) 19:41:27.627 SERIAL » [ACK] (0x06) 19:41:27.632 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.639 SERIAL » 0x010a00133003861386256685 (12 bytes) 19:41:27.634 CNTRLR » [Node 021] querying parameter #11 value... 19:41:27.630 DRIVER ACK already received, resolving transaction 19:41:27.631 DRIVER resuming send queue 19:41:27.638 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 102 └─[VersionCCCommandClassGet] payload: 0x86 19:41:27.640 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:27.645 SERIAL « [ACK] (0x06) 19:41:27.646 DRIVER ACK received from controller for current transaction 19:41:27.647 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.651 SERIAL « 0x0104011301e8 (6 bytes) 19:41:27.655 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:27.653 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:27.654 SERIAL » [ACK] (0x06) 19:41:27.656 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.730 SERIAL « 0x010700136600000984 (9 bytes) 19:41:27.734 DRIVER « [REQ] [SendData] [confirmation] callbackId: 102 transmitStatus: OK 19:41:27.732 SERIAL Buffer := 0x010700136600000984 (9 bytes) 19:41:27.733 SERIAL » [ACK] (0x06) 19:41:27.736 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.735 DRIVER ACK received from node for current transaction. RTT = 98.01 ms 19:41:27.748 SERIAL « 0x010a000400300486148603d2 (12 bytes) 19:41:27.753 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8603 19:41:27.757 CNTRLR [Node 048] supports CC Version (0x86) in version 3 19:41:27.750 SERIAL Buffer := 0x010a000400300486148603d2 (12 bytes) 19:41:27.751 SERIAL » [ACK] (0x06) 19:41:27.756 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.763 SERIAL » 0x010a0013150370050b2567cc (12 bytes) 19:41:27.754 DRIVER ACK already received, resolving transaction 19:41:27.755 DRIVER resuming send queue 19:41:27.762 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 103 └─[ConfigurationCCGet] payload: 0x0b 19:41:27.765 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:27.758 CNTRLR » [Node 048] querying the CC version for Association (0x85)... 19:41:27.770 SERIAL « [ACK] (0x06) 19:41:27.771 DRIVER ACK received from controller for current transaction 19:41:27.772 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.775 SERIAL « 0x0104011301e8 (6 bytes) 19:41:27.779 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:27.776 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:27.777 SERIAL » [ACK] (0x06) 19:41:27.781 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.797 SERIAL « 0x01070013670000038f (9 bytes) 19:41:27.801 DRIVER « [REQ] [SendData] [confirmation] callbackId: 103 transmitStatus: OK 19:41:27.798 SERIAL Buffer := 0x01070013670000038f (9 bytes) 19:41:27.799 SERIAL » [ACK] (0x06) 19:41:27.804 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.802 DRIVER ACK received from node for current transaction. RTT = 40.31 ms 19:41:27.840 SERIAL « 0x010c000400150670060b0200009b (14 bytes) 19:41:27.846 CNTRLR [Node 021] [+] [Configuration] 11: 0 19:41:27.853 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x0b020000 19:41:27.841 SERIAL Buffer := 0x010c000400150670060b0200009b (14 bytes) 19:41:27.851 SERIAL » [ACK] (0x06) 19:41:27.856 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.864 SERIAL » 0x010a00133003861385256888 (12 bytes) 19:41:27.858 CNTRLR » [Node 021] querying parameter #12 value... 19:41:27.854 DRIVER ACK already received, resolving transaction 19:41:27.855 DRIVER resuming send queue 19:41:27.863 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 104 └─[VersionCCCommandClassGet] payload: 0x85 19:41:27.865 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:27.871 SERIAL « [ACK] (0x06) 19:41:27.872 DRIVER ACK received from controller for current transaction 19:41:27.873 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.877 SERIAL « 0x0104011301e8 (6 bytes) 19:41:27.881 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:27.878 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:27.880 SERIAL » [ACK] (0x06) 19:41:27.883 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.971 SERIAL « 0x010700136800000a89 (9 bytes) 19:41:27.975 DRIVER « [REQ] [SendData] [confirmation] callbackId: 104 transmitStatus: OK 19:41:27.972 SERIAL Buffer := 0x010700136800000a89 (9 bytes) 19:41:27.974 SERIAL » [ACK] (0x06) 19:41:27.978 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:27.977 DRIVER ACK received from node for current transaction. RTT = 114.59 ms 19:41:27.988 SERIAL « 0x010a000400300486148502d0 (12 bytes) 19:41:27.993 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8502 19:41:27.998 CNTRLR [Node 048] supports CC Association (0x85) in version 2 19:41:27.989 SERIAL Buffer := 0x010a000400300486148502d0 (12 bytes) 19:41:27.991 SERIAL » [ACK] (0x06) 19:41:27.997 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.006 SERIAL » 0x010a0013150370050c2569c5 (12 bytes) 19:41:27.994 DRIVER ACK already received, resolving transaction 19:41:27.995 DRIVER resuming send queue 19:41:28.005 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 105 └─[ConfigurationCCGet] payload: 0x0c 19:41:28.007 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:28.000 CNTRLR » [Node 048] querying the CC version for Multi Channel Association (0x8e)... 19:41:28.013 SERIAL « [ACK] (0x06) 19:41:28.014 DRIVER ACK received from controller for current transaction 19:41:28.015 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.019 SERIAL « 0x0104011301e8 (6 bytes) 19:41:28.024 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:28.021 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:28.022 SERIAL » [ACK] (0x06) 19:41:28.025 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.040 SERIAL « 0x010700136900000381 (9 bytes) 19:41:28.044 DRIVER « [REQ] [SendData] [confirmation] callbackId: 105 transmitStatus: OK 19:41:28.041 SERIAL Buffer := 0x010700136900000381 (9 bytes) 19:41:28.042 SERIAL » [ACK] (0x06) 19:41:28.048 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.046 DRIVER ACK received from node for current transaction. RTT = 41.90 ms 19:41:28.085 SERIAL « 0x010c000400150670060c0200009c (14 bytes) 19:41:28.095 CNTRLR [Node 021] [+] [Configuration] 12: 0 19:41:28.104 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x0c020000 19:41:28.088 SERIAL Buffer := 0x010c000400150670060c0200009c (14 bytes) 19:41:28.101 SERIAL » [ACK] (0x06) 19:41:28.108 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.121 SERIAL » 0x010a0013300386138e256a81 (12 bytes) 19:41:28.110 CNTRLR » [Node 021] querying parameter #21 value... 19:41:28.105 DRIVER ACK already received, resolving transaction 19:41:28.106 DRIVER resuming send queue 19:41:28.120 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 106 └─[VersionCCCommandClassGet] payload: 0x8e 19:41:28.124 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:28.138 SERIAL « [ACK] (0x06) 19:41:28.140 DRIVER ACK received from controller for current transaction 19:41:28.141 SERIAL « 0x060104011301e8 (7 bytes) 19:41:28.143 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:28.144 SERIAL » [ACK] (0x06) 19:41:28.148 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.146 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:28.283 SERIAL « 0x010a000400300486148e03da (12 bytes) 19:41:28.291 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x8e03 19:41:28.297 CNTRLR [Node 048] supports CC Multi Channel Association (0x8e) in version 3 19:41:28.285 SERIAL Buffer := 0x010a000400300486148e03da (12 bytes) 19:41:28.287 SERIAL » [ACK] (0x06) 19:41:28.296 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.303 SERIAL » 0x010a00131503700515256bde (12 bytes) 19:41:28.293 DRIVER ACK already received, resolving transaction 19:41:28.294 DRIVER resuming send queue 19:41:28.303 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 107 └─[ConfigurationCCGet] payload: 0x15 19:41:28.304 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:28.299 CNTRLR » [Node 048] querying the CC version for Association Group Information (0x59). .. 19:41:28.326 SERIAL « 0x010700136a0000129318 (10 bytes) 19:41:28.331 DRIVER handling request SendData (19) 19:41:28.327 SERIAL Buffer := 0x010700136a0000129318 (10 bytes) 19:41:28.329 SERIAL » [ACK] (0x06) 19:41:28.335 SERIAL « [CAN] (0x18) 19:41:28.339 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.333 DRIVER no handlers registered! 19:41:28.338 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 19:41:28.348 SERIAL « 0x010a000400300486148e03da (12 bytes) 19:41:28.349 SERIAL Buffer := 0x010a000400300486148e03da (12 bytes) 19:41:28.352 SERIAL » [ACK] (0x06) 19:41:28.355 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.438 DRIVER » [Node 021] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 107 └─[ConfigurationCCGet] payload: 0x15 19:41:28.439 SERIAL » 0x010a00131503700515256bde (12 bytes) 19:41:28.444 SERIAL « [ACK] (0x06) 19:41:28.445 DRIVER ACK received from controller for current transaction 19:41:28.445 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.450 SERIAL « 0x0104011301e8 (6 bytes) 19:41:28.452 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:28.451 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:28.452 SERIAL » [ACK] (0x06) 19:41:28.454 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.474 SERIAL « 0x010700136b00000383 (9 bytes) 19:41:28.477 DRIVER « [REQ] [SendData] [confirmation] callbackId: 107 transmitStatus: OK 19:41:28.475 SERIAL Buffer := 0x010700136b00000383 (9 bytes) 19:41:28.476 SERIAL » [ACK] (0x06) 19:41:28.480 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.478 DRIVER ACK received from node for current transaction. RTT = 41.17 ms 19:41:28.540 SERIAL « 0x010b0004001505700615010082 (13 bytes) 19:41:28.547 CNTRLR [Node 021] [+] [Configuration] 21: 0 19:41:28.554 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x150100 19:41:28.541 SERIAL Buffer := 0x010b0004001505700615010082 (13 bytes) 19:41:28.552 SERIAL » [ACK] (0x06) 19:41:28.559 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.567 SERIAL » 0x010a00133003861359256c50 (12 bytes) 19:41:28.560 CNTRLR » [Node 021] querying parameter #30 value... 19:41:28.556 DRIVER ACK already received, resolving transaction 19:41:28.557 DRIVER resuming send queue 19:41:28.566 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 108 └─[VersionCCCommandClassGet] payload: 0x59 19:41:28.568 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:28.594 SERIAL « [ACK] (0x06) 19:41:28.595 DRIVER ACK received from controller for current transaction 19:41:28.597 SERIAL « 0x060104011301e8 (7 bytes) 19:41:28.599 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:28.600 SERIAL » [ACK] (0x06) 19:41:28.603 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.601 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:28.700 SERIAL « 0x010700136c00000c8b (9 bytes) 19:41:28.703 DRIVER « [REQ] [SendData] [confirmation] callbackId: 108 transmitStatus: OK 19:41:28.701 SERIAL Buffer := 0x010700136c00000c8b (9 bytes) 19:41:28.702 SERIAL » [ACK] (0x06) 19:41:28.705 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.704 DRIVER ACK received from node for current transaction. RTT = 139.36 ms 19:41:28.722 SERIAL « 0x010a0004003004861459010f (12 bytes) 19:41:28.727 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x5901 19:41:28.731 CNTRLR [Node 048] supports CC Association Group Information (0x59) in version 1 19:41:28.723 SERIAL Buffer := 0x010a0004003004861459010f (12 bytes) 19:41:28.725 SERIAL » [ACK] (0x06) 19:41:28.730 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.736 SERIAL » 0x010a0013150370051e256dd3 (12 bytes) 19:41:28.728 DRIVER ACK already received, resolving transaction 19:41:28.729 DRIVER resuming send queue 19:41:28.735 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 109 └─[ConfigurationCCGet] payload: 0x1e 19:41:28.737 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:28.732 CNTRLR » [Node 048] querying the CC version for Manufacturer Specific (0x72)... 19:41:28.743 SERIAL « [ACK] (0x06) 19:41:28.744 DRIVER ACK received from controller for current transaction 19:41:28.745 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.752 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:28.748 SERIAL « 0x0104011301e8 (6 bytes) 19:41:28.749 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:28.751 SERIAL » [ACK] (0x06) 19:41:28.753 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.775 SERIAL « 0x010700136d00000385 (9 bytes) 19:41:28.782 DRIVER « [REQ] [SendData] [confirmation] callbackId: 109 transmitStatus: OK 19:41:28.779 SERIAL Buffer := 0x010700136d00000385 (9 bytes) 19:41:28.780 SERIAL » [ACK] (0x06) 19:41:28.788 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.787 DRIVER ACK received from node for current transaction. RTT = 52.31 ms 19:41:28.812 SERIAL « 0x010b000400150570061e010089 (13 bytes) 19:41:28.817 CNTRLR [Node 021] [+] [Configuration] 30: 0 19:41:28.822 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x1e0100 19:41:28.813 SERIAL Buffer := 0x010b000400150570061e010089 (13 bytes) 19:41:28.821 SERIAL » [ACK] (0x06) 19:41:28.824 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.830 SERIAL » 0x010a00133003861372256e79 (12 bytes) 19:41:28.825 CNTRLR » [Node 021] querying parameter #40 value... 19:41:28.823 DRIVER ACK already received, resolving transaction 19:41:28.824 DRIVER resuming send queue 19:41:28.829 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 110 └─[VersionCCCommandClassGet] payload: 0x72 19:41:28.831 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:28.845 SERIAL « [ACK] (0x06) 19:41:28.847 DRIVER ACK received from controller for current transaction 19:41:28.848 SERIAL « 0x060104011301e8 (7 bytes) 19:41:28.849 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:28.850 SERIAL » [ACK] (0x06) 19:41:28.853 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.851 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:28.886 SERIAL « 0x010700136e00000481 (9 bytes) 19:41:28.889 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 19:41:28.887 SERIAL Buffer := 0x010700136e00000481 (9 bytes) 19:41:28.888 SERIAL » [ACK] (0x06) 19:41:28.891 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.890 DRIVER ACK received from node for current transaction. RTT = 62.17 ms 19:41:28.970 SERIAL « 0x010a00040030048614720227 (12 bytes) 19:41:28.975 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x7202 19:41:28.978 CNTRLR [Node 048] supports CC Manufacturer Specific (0x72) in version 2 19:41:28.972 SERIAL Buffer := 0x010a00040030048614720227 (12 bytes) 19:41:28.973 SERIAL » [ACK] (0x06) 19:41:28.977 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:28.983 SERIAL » 0x010a00131503700528256fe7 (12 bytes) 19:41:28.976 DRIVER ACK already received, resolving transaction 19:41:28.976 DRIVER resuming send queue 19:41:28.982 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 111 └─[ConfigurationCCGet] payload: 0x28 19:41:28.984 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:28.979 CNTRLR [Node 048] skipping query for Device Reset Locally (0x5a) because max implem ented version is 1 19:41:28.979 CNTRLR » [Node 048] querying the CC version for Multilevel Switch (0x26)... 19:41:28.994 SERIAL « [ACK] (0x06) 19:41:28.995 DRIVER ACK received from controller for current transaction 19:41:28.996 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.004 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:29.001 SERIAL « 0x0104011301e8 (6 bytes) 19:41:29.002 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:29.003 SERIAL » [ACK] (0x06) 19:41:29.006 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.021 SERIAL « 0x010700136f00000286 (9 bytes) 19:41:29.025 DRIVER « [REQ] [SendData] [confirmation] callbackId: 111 transmitStatus: OK 19:41:29.022 SERIAL Buffer := 0x010700136f00000286 (9 bytes) 19:41:29.023 SERIAL » [ACK] (0x06) 19:41:29.028 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.026 DRIVER ACK received from node for current transaction. RTT = 44.23 ms 19:41:29.056 SERIAL « 0x010b00040015057006280105ba (13 bytes) 19:41:29.062 CNTRLR [Node 021] [+] [Configuration] 40: 5 19:41:29.066 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x280105 19:41:29.057 SERIAL Buffer := 0x010b00040015057006280105ba (13 bytes) 19:41:29.065 SERIAL » [ACK] (0x06) 19:41:29.069 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.074 SERIAL » 0x010a00133003861326257033 (12 bytes) 19:41:29.070 CNTRLR » [Node 021] querying parameter #42 value... 19:41:29.067 DRIVER ACK already received, resolving transaction 19:41:29.068 DRIVER resuming send queue 19:41:29.073 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 112 └─[VersionCCCommandClassGet] payload: 0x26 19:41:29.075 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:29.088 SERIAL « [ACK] (0x06) 19:41:29.090 DRIVER ACK received from controller for current transaction 19:41:29.091 SERIAL « 0x060104011301e8 (7 bytes) 19:41:29.092 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:29.093 SERIAL » [ACK] (0x06) 19:41:29.096 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.095 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:29.119 SERIAL « 0x010a00040030048614260475 (12 bytes) 19:41:29.124 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x2604 19:41:29.128 CNTRLR [Node 048] supports CC Multilevel Switch (0x26) in version 4 19:41:29.120 SERIAL Buffer := 0x010a00040030048614260475 (12 bytes) 19:41:29.122 SERIAL » [ACK] (0x06) 19:41:29.127 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.135 SERIAL » 0x010a0013150370052a2571fb (12 bytes) 19:41:29.125 DRIVER ACK already received, resolving transaction 19:41:29.126 DRIVER resuming send queue 19:41:29.134 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 113 └─[ConfigurationCCGet] payload: 0x2a 19:41:29.137 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:29.130 CNTRLR » [Node 048] querying the CC version for Binary Switch (0x25)... 19:41:29.148 SERIAL « [ACK] (0x06) 19:41:29.149 DRIVER ACK received from controller for current transaction 19:41:29.150 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.158 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:29.154 SERIAL « 0x0104011301e8 (6 bytes) 19:41:29.155 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:29.156 SERIAL » [ACK] (0x06) 19:41:29.162 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.250 SERIAL « 0x010a00040030048614260475 (12 bytes) 19:41:29.252 SERIAL Buffer := 0x010a00040030048614260475 (12 bytes) 19:41:29.254 SERIAL » [ACK] (0x06) 19:41:29.256 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.373 SERIAL « 0x01070013710000168c (9 bytes) 19:41:29.379 DRIVER « [REQ] [SendData] [confirmation] callbackId: 113 transmitStatus: OK 19:41:29.375 SERIAL Buffer := 0x01070013710000168c (9 bytes) 19:41:29.376 SERIAL » [ACK] (0x06) 19:41:29.387 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.385 DRIVER ACK received from node for current transaction. RTT = 251.35 ms 19:41:29.394 SERIAL « 0x010700137100001882 (9 bytes) 19:41:29.396 SERIAL Buffer := 0x010700137100001882 (9 bytes) 19:41:29.397 SERIAL » [ACK] (0x06) 19:41:29.403 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.399 DRIVER « [REQ] [SendData] [confirmation] callbackId: 113 transmitStatus: OK 19:41:29.401 DRIVER ACK received from node for current transaction. RTT = 266.88 ms 19:41:29.429 SERIAL « 0x010c000400150670062a020000ba (14 bytes) 19:41:29.435 CNTRLR [Node 021] [+] [Configuration] 42: 0 19:41:29.441 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x2a020000 19:41:29.430 SERIAL Buffer := 0x010c000400150670062a020000ba (14 bytes) 19:41:29.439 SERIAL » [ACK] (0x06) 19:41:29.444 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.449 SERIAL » 0x010a00133003861325257232 (12 bytes) 19:41:29.445 CNTRLR » [Node 021] querying parameter #60 value... 19:41:29.442 DRIVER ACK already received, resolving transaction 19:41:29.443 DRIVER resuming send queue 19:41:29.448 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 114 └─[VersionCCCommandClassGet] payload: 0x25 19:41:29.450 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:29.464 SERIAL « [ACK] (0x06) 19:41:29.467 DRIVER ACK received from controller for current transaction 19:41:29.469 SERIAL « 0x060104011301e8 (7 bytes) 19:41:29.470 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:29.471 SERIAL » [ACK] (0x06) 19:41:29.473 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.472 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:29.489 CNTRLR [Node 048] supports CC Binary Switch (0x25) in version 4 19:41:29.476 SERIAL « 0x010a00040030048614260475 (12 bytes) 19:41:29.477 SERIAL Buffer := 0x010a00040030048614260475 (12 bytes) 19:41:29.479 SERIAL » [ACK] (0x06) 19:41:29.488 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.497 SERIAL » 0x010a0013150370053c2573ef (12 bytes) 19:41:29.482 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x2604 19:41:29.484 DRIVER ACK already received, resolving transaction 19:41:29.487 DRIVER resuming send queue 19:41:29.496 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 115 └─[ConfigurationCCGet] payload: 0x3c 19:41:29.498 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:29.490 CNTRLR » [Node 048] querying the CC version for Configuration (0x70)... 19:41:29.515 SERIAL « [ACK] (0x06) 19:41:29.517 DRIVER ACK received from controller for current transaction 19:41:29.518 SERIAL « 0x060104011301e8 (7 bytes) 19:41:29.519 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:29.520 SERIAL » [ACK] (0x06) 19:41:29.524 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.522 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:29.600 SERIAL « 0x010700137300000a92 (9 bytes) 19:41:29.610 DRIVER « [REQ] [SendData] [confirmation] callbackId: 115 transmitStatus: OK 19:41:29.604 SERIAL Buffer := 0x010700137300000a92 (9 bytes) 19:41:29.606 SERIAL » [ACK] (0x06) 19:41:29.612 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.611 DRIVER ACK received from node for current transaction. RTT = 115.73 ms 19:41:29.626 SERIAL « 0x010700137300000c94 (9 bytes) 19:41:29.633 DRIVER « [REQ] [SendData] [confirmation] callbackId: 115 transmitStatus: OK 19:41:29.627 SERIAL Buffer := 0x010700137300000c94 (9 bytes) 19:41:29.631 SERIAL » [ACK] (0x06) 19:41:29.635 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.634 DRIVER ACK received from node for current transaction. RTT = 138.29 ms 19:41:29.664 SERIAL « 0x010b000400150570063c0101aa (13 bytes) 19:41:29.668 CNTRLR [Node 021] [+] [Configuration] 60: 1 19:41:29.673 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x3c0101 19:41:29.665 SERIAL Buffer := 0x010b000400150570063c0101aa (13 bytes) 19:41:29.671 SERIAL » [ACK] (0x06) 19:41:29.675 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.680 SERIAL » 0x010a00133003861370257461 (12 bytes) 19:41:29.676 CNTRLR » [Node 021] querying parameter #61 value... 19:41:29.674 DRIVER ACK already received, resolving transaction 19:41:29.674 DRIVER resuming send queue 19:41:29.680 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 116 └─[VersionCCCommandClassGet] payload: 0x70 19:41:29.681 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:29.686 SERIAL « 0x010a0004003004861425 (10 bytes) 19:41:29.687 SERIAL [incomplete] Buffer := 0x010a0004003004861425 (10 bytes) 19:41:29.705 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x2501 19:41:29.694 SERIAL « 0x017318 (3 bytes) 19:41:29.697 SERIAL Buffer := 0x010a0004003004861425017318 (13 bytes) 19:41:29.700 SERIAL » [ACK] (0x06) 19:41:29.708 SERIAL « [CAN] (0x18) 19:41:29.710 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.707 DRIVER no ACK received yet, remembering response 19:41:29.709 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 19:41:29.737 SERIAL « 0x010a00040030048614250173 (12 bytes) 19:41:29.744 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[VersionCCCommandClassReport] payload: 0x2501 19:41:29.739 SERIAL Buffer := 0x010a00040030048614250173 (12 bytes) 19:41:29.741 SERIAL » [ACK] (0x06) 19:41:29.749 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.747 DRIVER no ACK received yet, remembering response 19:41:29.810 DRIVER » [Node 048] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 116 └─[VersionCCCommandClassGet] payload: 0x70 19:41:29.811 SERIAL » 0x010a00133003861370257461 (12 bytes) 19:41:29.815 SERIAL « [ACK] (0x06) 19:41:29.816 DRIVER ACK received from controller for current transaction 19:41:29.818 CNTRLR [Node 048] supports CC Configuration (0x70) in version 1 19:41:29.817 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.826 SERIAL » 0x010a0013150370053d2575e8 (12 bytes) 19:41:29.817 DRIVER transaction finished, resolving... 19:41:29.825 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 117 └─[ConfigurationCCGet] payload: 0x3d 19:41:29.819 CNTRLR [Node 048] skipping query for Supervision (0x6c) because max implemented ver sion is 1 19:41:29.820 CNTRLR » [Node 048] querying if Z-Wave Software Get is supported... 19:41:29.828 SERIAL « 0x0104011301e8 (6 bytes) 19:41:29.829 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:29.830 SERIAL » [ACK] (0x06) 19:41:29.831 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.830 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:29.835 SERIAL « [CAN] (0x18) 19:41:29.837 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.836 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 19:41:29.854 SERIAL « 0x010a00040030048614700126 (12 bytes) 19:41:29.856 SERIAL Buffer := 0x010a00040030048614700126 (12 bytes) 19:41:29.858 SERIAL » [ACK] (0x06) 19:41:29.860 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.937 DRIVER » [Node 021] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 117 └─[ConfigurationCCGet] payload: 0x3d 19:41:29.939 SERIAL » 0x010a0013150370053d2575e8 (12 bytes) 19:41:29.949 SERIAL « [ACK] (0x06) 19:41:29.951 DRIVER ACK received from controller for current transaction 19:41:29.952 SERIAL « 0x060104011301e8 (7 bytes) 19:41:29.953 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:29.955 SERIAL » [ACK] (0x06) 19:41:29.957 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.956 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:29.975 SERIAL « 0x01070013750000019f (9 bytes) 19:41:29.980 DRIVER « [REQ] [SendData] [confirmation] callbackId: 117 transmitStatus: OK 19:41:29.977 SERIAL Buffer := 0x01070013750000019f (9 bytes) 19:41:29.978 SERIAL » [ACK] (0x06) 19:41:29.982 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:29.981 DRIVER ACK received from node for current transaction. RTT = 44.17 ms 19:41:29.992 SERIAL « 0x010a00040030048614700126 (12 bytes) 19:41:29.994 SERIAL Buffer := 0x010a00040030048614700126 (12 bytes) 19:41:29.995 SERIAL » [ACK] (0x06) 19:41:29.997 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:30.003 SERIAL « 0x01070013750000059b (9 bytes) 19:41:30.006 DRIVER « [REQ] [SendData] [confirmation] callbackId: 117 transmitStatus: OK 19:41:30.004 SERIAL Buffer := 0x01070013750000059b (9 bytes) 19:41:30.005 SERIAL » [ACK] (0x06) 19:41:30.008 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:30.007 DRIVER ACK received from node for current transaction. RTT = 70.35 ms 19:41:30.028 SERIAL « 0x010b000400150570063d0163c9 (13 bytes) 19:41:30.032 CNTRLR [Node 021] [+] [Configuration] 61: 99 19:41:30.037 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x3d0163 19:41:30.029 SERIAL Buffer := 0x010b000400150570063d0163c9 (13 bytes) 19:41:30.035 SERIAL » [ACK] (0x06) 19:41:30.044 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:30.050 SERIAL » 0x0109001330028615257617 (11 bytes) 19:41:30.045 CNTRLR » [Node 021] querying parameter #65 value... 19:41:30.043 DRIVER ACK already received, resolving transaction 19:41:30.043 DRIVER resuming send queue 19:41:30.049 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 118 └─[VersionCCCapabilitiesGet] 19:41:30.050 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:30.067 SERIAL « [ACK] (0x06) 19:41:30.069 DRIVER ACK received from controller for current transaction 19:41:30.070 SERIAL « 0x060104011301e8 (7 bytes) 19:41:30.071 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:30.072 SERIAL » [ACK] (0x06) 19:41:30.076 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:30.074 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:30.201 SERIAL « 0x010700137600000f92 (9 bytes) 19:41:30.206 DRIVER « [REQ] [SendData] [confirmation] callbackId: 118 transmitStatus: OK 19:41:30.202 SERIAL Buffer := 0x010700137600000f92 (9 bytes) 19:41:30.204 SERIAL » [ACK] (0x06) 19:41:30.209 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:30.208 DRIVER ACK received from node for current transaction. RTT = 159.47 ms 19:41:30.242 SERIAL « 0x0109000400300386160756 (11 bytes) 19:41:30.248 CNTRLR [Node 048] [+] [Version] supportsZWaveSoftwareGet: tru [Endpoint 0] [internal] e 19:41:30.251 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[VersionCCCapabilitiesReport] payload: 0x07 19:41:30.243 SERIAL Buffer := 0x0109000400300386160756 (11 bytes) 19:41:30.249 SERIAL » [ACK] (0x06) 19:41:30.253 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:30.263 SERIAL » 0x010a00131503700541257796 (12 bytes) 19:41:30.254 CNTRLR « [Node 048] Z-Wave Software Get is supported 19:41:30.255 CNTRLR » [Node 048] querying Z-Wave software versions... 19:41:30.252 DRIVER ACK already received, resolving transaction 19:41:30.252 DRIVER resuming send queue 19:41:30.262 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 119 └─[ConfigurationCCGet] payload: 0x41 19:41:30.264 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:30.268 SERIAL « [ACK] (0x06) 19:41:30.269 DRIVER ACK received from controller for current transaction 19:41:30.270 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:30.274 SERIAL « 0x0104011301e8 (6 bytes) 19:41:30.277 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:30.275 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:30.276 SERIAL » [ACK] (0x06) 19:41:30.278 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:30.299 DRIVER « [REQ] [SendData] [confirmation] callbackId: 119 transmitStatus: OK 19:41:30.295 SERIAL « 0x01070013770000029e (9 bytes) 19:41:30.296 SERIAL Buffer := 0x01070013770000029e (9 bytes) 19:41:30.297 SERIAL » [ACK] (0x06) 19:41:30.301 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:30.300 DRIVER ACK received from node for current transaction. RTT = 38.57 ms 19:41:30.337 SERIAL « 0x010c0004001506700641020064b5 (14 bytes) 19:41:30.342 CNTRLR [Node 021] [+] [Configuration] 65: 100 19:41:30.347 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x41020064 19:41:30.338 SERIAL Buffer := 0x010c0004001506700641020064b5 (14 bytes) 19:41:30.346 SERIAL » [ACK] (0x06) 19:41:30.350 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:30.356 SERIAL » 0x010900133002861725781b (11 bytes) 19:41:30.351 CNTRLR » [Node 021] querying parameter #66 value... 19:41:30.348 DRIVER ACK already received, resolving transaction 19:41:30.349 DRIVER resuming send queue 19:41:30.355 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 120 └─[VersionCCZWaveSoftwareGet] 19:41:30.357 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:30.362 SERIAL « [ACK] (0x06) 19:41:30.363 DRIVER ACK received from controller for current transaction 19:41:30.365 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:30.372 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:30.368 SERIAL « 0x0104011301e8 (6 bytes) 19:41:30.369 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:30.371 SERIAL » [ACK] (0x06) 19:41:30.373 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:30.404 SERIAL « 0x011f00040030198618065100040100ccdd0000000000060100003a040100ccdd3 (33 bytes) 9 19:41:30.414 CNTRLR [Node 048] [+] [Version] sdkVersion: "6.81.0" [Endpoint 0] 19:41:30.472 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[VersionCCZWaveSoftwareReport] payload: 0x065100040100ccdd0000000000060100003a040100ccdd 19:41:30.406 SERIAL Buffer := 0x011f00040030198618065100040100ccdd0000000000060100003a0 (33 bytes) 40100ccdd39 19:41:30.470 SERIAL » [ACK] (0x06) 19:41:30.476 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:30.495 SERIAL » 0x010a0013150370054225799b (12 bytes) 19:41:30.421 CNTRLR [Node 048] [+] [Version] applicationFrameworkAPIVersion: "4.1.0" [Endpoint 0] 19:41:30.428 CNTRLR [Node 048] [+] [Version] applicationFrameworkBuildNumber: 52445 [Endpoint 0] 19:41:30.434 CNTRLR [Node 048] [+] [Version] hostInterfaceVersion: "unused" [Endpoint 0] 19:41:30.443 CNTRLR [Node 048] [+] [Version] hostInterfaceBuildNumber: 0 [Endpoint 0] 19:41:30.449 CNTRLR [Node 048] [+] [Version] zWaveProtocolVersion: "6.1.0" [Endpoint 0] 19:41:30.454 CNTRLR [Node 048] [+] [Version] zWaveProtocolBuildNumber: 58 [Endpoint 0] 19:41:30.460 CNTRLR [Node 048] [+] [Version] applicationVersion: "4.1.0" [Endpoint 0] 19:41:30.466 CNTRLR [Node 048] [+] [Version] applicationBuildNumber: 52445 [Endpoint 0] 19:41:30.478 CNTRLR « [Node 048] received Z-Wave software versions.. 19:41:30.480 CNTRLR [Node 048] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 19:41:30.481 CNTRLR [Node 048] trying to load device config 19:41:30.473 DRIVER ACK already received, resolving transaction 19:41:30.474 DRIVER resuming send queue 19:41:30.494 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 121 └─[ConfigurationCCGet] payload: 0x42 19:41:30.500 SERIAL « 0x010700137800000794 (9 bytes) 19:41:30.501 SERIAL Buffer := 0x010700137800000794 (9 bytes) 19:41:30.502 SERIAL » [ACK] (0x06) 19:41:30.507 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:30.504 DRIVER handling request SendData (19) 19:41:30.505 DRIVER no handlers registered! 19:41:30.534 SERIAL « [CAN] (0x18) 19:41:30.540 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:30.538 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 19:41:30.597 CNTRLR [Node 048] device config loaded 19:41:30.742 SERIAL « 0x011f00040030198618065100040100ccdd0000000000060100003a040100ccdd3 (33 bytes) 9 19:41:30.748 CNTRLR [Node 048] [~] [Version] sdkVersion: "6.81.0" => "6.81.0" [Endpoint 0] 19:41:30.833 DRIVER » [Node 021] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 121 └─[ConfigurationCCGet] payload: 0x42 19:41:30.744 SERIAL Buffer := 0x011f00040030198618065100040100ccdd0000000000060100003a0 (33 bytes) 40100ccdd39 19:41:30.794 SERIAL » [ACK] (0x06) 19:41:30.796 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:30.835 SERIAL » 0x010a0013150370054225799b (12 bytes) 19:41:30.753 CNTRLR [Node 048] [~] [Version] applicationFrameworkAPIVersion: "4.1.0" [Endpoint 0] => "4.1.0" 19:41:30.758 CNTRLR [Node 048] [~] [Version] applicationFrameworkBuildNumber: 52445 = [Endpoint 0] > 52445 19:41:30.763 CNTRLR [Node 048] [~] [Version] hostInterfaceVersion: "unused" => "unuse [Endpoint 0] d" 19:41:30.769 CNTRLR [Node 048] [~] [Version] hostInterfaceBuildNumber: 0 => 0 [Endpoint 0] 19:41:30.774 CNTRLR [Node 048] [~] [Version] zWaveProtocolVersion: "6.1.0" => "6.1.0" [Endpoint 0] 19:41:30.779 CNTRLR [Node 048] [~] [Version] zWaveProtocolBuildNumber: 58 => 58 [Endpoint 0] 19:41:30.785 CNTRLR [Node 048] [~] [Version] applicationVersion: "4.1.0" => "4.1.0" [Endpoint 0] 19:41:30.790 CNTRLR [Node 048] [~] [Version] applicationBuildNumber: 52445 => 52445 [Endpoint 0] 19:41:30.870 CNTRLR [Node 048] ZWavePlusCC: doing a complete interview... 19:41:30.880 SERIAL « [ACK] (0x06) 19:41:30.882 DRIVER ACK received from controller for current transaction 19:41:30.872 CNTRLR » [Node 048] querying Z-Wave+ information... 19:41:30.884 SERIAL « 0x060104011301e8 (7 bytes) 19:41:30.885 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:30.886 SERIAL » [ACK] (0x06) 19:41:30.891 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:30.889 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:30.902 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:30.907 SERIAL « 0x010700137900000290 (9 bytes) 19:41:30.908 SERIAL Buffer := 0x010700137900000290 (9 bytes) 19:41:30.910 SERIAL » [ACK] (0x06) 19:41:30.917 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:30.913 DRIVER « [REQ] [SendData] [confirmation] callbackId: 121 transmitStatus: OK 19:41:30.915 DRIVER ACK received from node for current transaction. RTT = 82.73 ms 19:41:30.939 CNTRLR [Node 021] [+] [Configuration] 66: 3 19:41:30.934 SERIAL « 0x010c0004001506700642020003d1 (14 bytes) 19:41:30.935 SERIAL Buffer := 0x010c0004001506700642020003d1 (14 bytes) 19:41:30.942 SERIAL » [ACK] (0x06) 19:41:30.947 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:30.981 SERIAL » 0x010a00131503700543257a99 (12 bytes) 19:41:30.944 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x42020003 19:41:30.945 DRIVER ACK already received, resolving transaction 19:41:30.946 DRIVER resuming send queue 19:41:30.979 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 122 └─[ConfigurationCCGet] payload: 0x43 19:41:30.982 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:30.948 CNTRLR » [Node 021] querying parameter #67 value... 19:41:31.007 SERIAL « [ACK] (0x06) 19:41:31.009 DRIVER ACK received from controller for current transaction 19:41:31.010 SERIAL « 0x060104011301e8 (7 bytes) 19:41:31.012 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:31.014 SERIAL » [ACK] (0x06) 19:41:31.018 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:31.015 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:31.021 SERIAL « 0x010700137a00000293 (9 bytes) 19:41:31.022 SERIAL Buffer := 0x010700137a00000293 (9 bytes) 19:41:31.024 SERIAL » [ACK] (0x06) 19:41:31.030 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:31.026 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 19:41:31.027 DRIVER ACK received from node for current transaction. RTT = 49.33 ms 19:41:31.058 SERIAL « 0x010b00040015057006430100d4 (13 bytes) 19:41:31.065 CNTRLR [Node 021] [+] [Configuration] 67: 0 19:41:31.074 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x430100 19:41:31.059 SERIAL Buffer := 0x010b00040015057006430100d4 (13 bytes) 19:41:31.071 SERIAL » [ACK] (0x06) 19:41:31.079 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:31.088 SERIAL » 0x010a00131503700544257b9f (12 bytes) 19:41:31.080 CNTRLR » [Node 021] querying parameter #68 value... 19:41:31.076 DRIVER ACK already received, resolving transaction 19:41:31.077 DRIVER resuming send queue 19:41:31.086 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 123 └─[ConfigurationCCGet] payload: 0x44 19:41:31.089 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:31.110 SERIAL « [ACK] (0x06) 19:41:31.112 DRIVER ACK received from controller for current transaction 19:41:31.114 SERIAL « 0x060104011301e8 (7 bytes) 19:41:31.115 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:31.116 SERIAL » [ACK] (0x06) 19:41:31.118 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:31.117 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:31.132 SERIAL « 0x010700137b00000393 (9 bytes) 19:41:31.137 DRIVER « [REQ] [SendData] [confirmation] callbackId: 123 transmitStatus: OK 19:41:31.133 SERIAL Buffer := 0x010700137b00000393 (9 bytes) 19:41:31.135 SERIAL » [ACK] (0x06) 19:41:31.140 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:31.138 DRIVER ACK received from node for current transaction. RTT = 53.70 ms 19:41:31.161 SERIAL « 0x010b00040015057006440100d3 (13 bytes) 19:41:31.166 CNTRLR [Node 021] [+] [Configuration] 68: 0 19:41:31.172 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x440100 19:41:31.162 SERIAL Buffer := 0x010b00040015057006440100d3 (13 bytes) 19:41:31.170 SERIAL » [ACK] (0x06) 19:41:31.175 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:31.180 SERIAL » 0x010a0013150370056e257cb2 (12 bytes) 19:41:31.176 CNTRLR » [Node 021] querying parameter #110 value... 19:41:31.173 DRIVER ACK already received, resolving transaction 19:41:31.173 DRIVER resuming send queue 19:41:31.179 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 124 └─[ConfigurationCCGet] payload: 0x6e 19:41:31.182 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:31.196 SERIAL « [ACK] (0x06) 19:41:31.197 DRIVER ACK received from controller for current transaction 19:41:31.199 SERIAL « 0x060104011301e8 (7 bytes) 19:41:31.200 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:31.202 SERIAL » [ACK] (0x06) 19:41:31.205 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:31.203 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:31.219 SERIAL « 0x010700137c00000295 (9 bytes) 19:41:31.225 DRIVER « [REQ] [SendData] [confirmation] callbackId: 124 transmitStatus: OK 19:41:31.221 SERIAL Buffer := 0x010700137c00000295 (9 bytes) 19:41:31.223 SERIAL » [ACK] (0x06) 19:41:31.229 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:31.227 DRIVER ACK received from node for current transaction. RTT = 47.77 ms 19:41:31.255 SERIAL « 0x010c000400150670066e027f1899 (14 bytes) 19:41:31.260 CNTRLR [Node 021] [+] [Configuration] 110: 32536 19:41:31.266 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x6e027f18 19:41:31.256 SERIAL Buffer := 0x010c000400150670066e027f1899 (14 bytes) 19:41:31.264 SERIAL » [ACK] (0x06) 19:41:31.269 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:31.274 SERIAL » 0x010a00131503700578257da5 (12 bytes) 19:41:31.270 CNTRLR » [Node 021] querying parameter #120 value... 19:41:31.267 DRIVER ACK already received, resolving transaction 19:41:31.267 DRIVER resuming send queue 19:41:31.273 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 125 └─[ConfigurationCCGet] payload: 0x78 19:41:31.275 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:31.284 SERIAL « [ACK] (0x06) 19:41:31.286 DRIVER ACK received from controller for current transaction 19:41:31.288 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:31.293 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:31.291 SERIAL « 0x0104011301e8 (6 bytes) 19:41:31.292 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:31.293 SERIAL » [ACK] (0x06) 19:41:31.295 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:31.307 SERIAL « 0x010700137d00000395 (9 bytes) 19:41:31.312 DRIVER « [REQ] [SendData] [confirmation] callbackId: 125 transmitStatus: OK 19:41:31.309 SERIAL Buffer := 0x010700137d00000395 (9 bytes) 19:41:31.310 SERIAL » [ACK] (0x06) 19:41:31.316 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:31.314 DRIVER ACK received from node for current transaction. RTT = 40.89 ms 19:41:31.347 SERIAL « 0x010b00040015057006780105ea (13 bytes) 19:41:31.354 CNTRLR [Node 021] [+] [Configuration] 120: 5 19:41:31.362 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x780105 19:41:31.349 SERIAL Buffer := 0x010b00040015057006780105ea (13 bytes) 19:41:31.360 SERIAL » [ACK] (0x06) 19:41:31.365 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:31.371 SERIAL » 0x0109001330025e01257ed3 (11 bytes) 19:41:31.367 CNTRLR [Node 021] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 19:41:31.363 DRIVER ACK already received, resolving transaction 19:41:31.364 DRIVER resuming send queue 19:41:31.370 DRIVER » [Node 048] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 126 └─[ZWavePlusCCGet] 19:41:31.538 SERIAL « [ACK] (0x06) 19:41:31.540 DRIVER ACK received from controller for current transaction 19:41:31.541 SERIAL « 0x060104011301e8 (7 bytes) 19:41:31.542 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:31.543 SERIAL » [ACK] (0x06) 19:41:31.547 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:31.545 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:31.560 SERIAL « 0x010700137e00000590 (9 bytes) 19:41:31.562 SERIAL Buffer := 0x010700137e00000590 (9 bytes) 19:41:31.564 SERIAL » [ACK] (0x06) 19:41:31.572 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:31.567 DRIVER « [REQ] [SendData] [confirmation] callbackId: 126 transmitStatus: OK 19:41:31.569 DRIVER ACK received from node for current transaction. RTT = 199.70 ms 19:41:31.579 CNTRLR [Node 021] AssociationCC: skipping interview because Multi Channel Association is supported... 19:41:31.592 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:31.583 CNTRLR [Node 021] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 19:41:31.586 CNTRLR [Node 021] MultiChannelAssociationCC: doing a complete interview... 19:41:31.587 CNTRLR » [Node 021] querying number of association groups... 19:41:31.615 SERIAL « 0x010f00040030095e020105001900190095 (17 bytes) 19:41:31.622 CNTRLR [Node 048] [+] [Z-Wave Plus Info] zwavePlusVersion: 1 [Endpoint 0] 19:41:31.655 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[ZWavePlusCCReport] payload: 0x01050019001900 19:41:31.616 SERIAL Buffer := 0x010f00040030095e020105001900190095 (17 bytes) 19:41:31.653 SERIAL » [ACK] (0x06) 19:41:31.659 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:31.696 SERIAL » 0x0109001315028e05257f23 (11 bytes) 19:41:31.627 CNTRLR [Node 048] [+] [Z-Wave Plus Info] nodeType: 0 [Endpoint 0] 19:41:31.633 CNTRLR [Node 048] [+] [Z-Wave Plus Info] roleType: 5 [Endpoint 0] 19:41:31.641 CNTRLR [Node 048] [+] [Z-Wave Plus Info] installerIcon: 6400 [Endpoint 0] 19:41:31.648 CNTRLR [Node 048] [+] [Z-Wave Plus Info] userIcon: 6400 [Endpoint 0] 19:41:31.670 CNTRLR « [Node 048] received response for Z-Wave+ information: Z-Wave+ version: 1 role type: AlwaysOnSlave node type: Node installer icon: 0x1900 user icon: 0x1900 19:41:31.673 CNTRLR [Node 048] [+] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue 19:41:31.677 CNTRLR [Node 048] MultilevelSwitchCC: doing a complete interview... 19:41:31.679 CNTRLR » [Node 048] requesting switch type... 19:41:31.656 DRIVER ACK already received, resolving transaction 19:41:31.657 DRIVER resuming send queue 19:41:31.695 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 127 └─[MultiChannelAssociationCCSupportedGroupingsGet] 19:41:31.698 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:31.704 SERIAL « [ACK] (0x06) 19:41:31.709 DRIVER ACK received from controller for current transaction 19:41:31.710 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:31.717 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:31.713 SERIAL « 0x0104011301e8 (6 bytes) 19:41:31.714 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:31.715 SERIAL » [ACK] (0x06) 19:41:31.718 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:31.730 SERIAL « 0x010700137f00000397 (9 bytes) 19:41:31.734 DRIVER « [REQ] [SendData] [confirmation] callbackId: 127 transmitStatus: OK 19:41:31.731 SERIAL Buffer := 0x010700137f00000397 (9 bytes) 19:41:31.732 SERIAL » [ACK] (0x06) 19:41:31.737 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:31.735 DRIVER ACK received from node for current transaction. RTT = 41.29 ms 19:41:31.892 SERIAL « 0x010900040015038e060569 (11 bytes) 19:41:31.896 CNTRLR [Node 021] [+] [Multi Channel Association] groupCount: [Endpoint 0] [internal] 5 19:41:31.898 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCSupportedGroupingsReport] payload: 0x05 19:41:31.893 SERIAL Buffer := 0x010900040015038e060569 (11 bytes) 19:41:31.897 SERIAL » [ACK] (0x06) 19:41:31.901 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:31.916 SERIAL » 0x0109001330022606258052 (11 bytes) 19:41:31.901 CNTRLR « [Node 021] supports 5 association groups 19:41:31.902 CNTRLR » [Node 021] querying association group #1... 19:41:31.899 DRIVER ACK already received, resolving transaction 19:41:31.900 DRIVER resuming send queue 19:41:31.915 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 128 └─[MultilevelSwitchCCSupportedGet] 19:41:31.917 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:31.923 SERIAL « [ACK] (0x06) 19:41:31.924 DRIVER ACK received from controller for current transaction 19:41:31.924 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:31.927 SERIAL « 0x0104011301e8 (6 bytes) 19:41:31.931 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:31.929 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:31.930 SERIAL » [ACK] (0x06) 19:41:31.932 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.062 SERIAL « 0x010a000400300426070500e1 (12 bytes) 19:41:32.069 CNTRLR [Node 048] [+] [Multilevel Switch] switchType: 5 [Endpoint 0] [internal] 19:41:32.082 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[MultilevelSwitchCCSupportedReport] payload: 0x0500 19:41:32.063 SERIAL Buffer := 0x010a000400300426070500e1 (12 bytes) 19:41:32.081 SERIAL » [ACK] (0x06) 19:41:32.085 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.094 SERIAL » 0x010a001315038e02012581d9 (12 bytes) 19:41:32.072 CNTRLR [Node 048] [Multilevel Switch] Left: metadata updated [Endpoint 0] 19:41:32.077 CNTRLR [Node 048] [Multilevel Switch] Right: metadata updated [Endpoint 0] 19:41:32.086 CNTRLR « [Node 048] has switch type Left/Right 19:41:32.087 CNTRLR » [Node 048] requesting current switch state... 19:41:32.084 DRIVER ACK already received, resolving transaction 19:41:32.084 DRIVER resuming send queue 19:41:32.093 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 129 └─[MultiChannelAssociationCCGet] payload: 0x01 19:41:32.095 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:32.098 SERIAL « 0x010a000400300426070500e1 (12 bytes) 19:41:32.099 SERIAL Buffer := 0x010a000400300426070500e1 (12 bytes) 19:41:32.119 SERIAL » [ACK] (0x06) 19:41:32.121 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.104 CNTRLR [Node 048] [~] [Multilevel Switch] switchType: 5 => 5 [Endpoint 0] [internal] 19:41:32.108 CNTRLR [Node 048] [Multilevel Switch] Left: metadata updated [Endpoint 0] 19:41:32.115 CNTRLR [Node 048] [Multilevel Switch] Right: metadata updated [Endpoint 0] 19:41:32.139 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 19:41:32.137 SERIAL « [CAN] (0x18) 19:41:32.140 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.208 SERIAL « 0x010700138000001c77 (9 bytes) 19:41:32.212 DRIVER handling request SendData (19) 19:41:32.210 SERIAL Buffer := 0x010700138000001c77 (9 bytes) 19:41:32.211 SERIAL » [ACK] (0x06) 19:41:32.217 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.215 DRIVER no handlers registered! 19:41:32.239 DRIVER » [Node 021] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 129 └─[MultiChannelAssociationCCGet] payload: 0x01 19:41:32.240 SERIAL » 0x010a001315038e02012581d9 (12 bytes) 19:41:32.245 SERIAL « [ACK] (0x06) 19:41:32.247 DRIVER ACK received from controller for current transaction 19:41:32.248 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.254 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:32.251 SERIAL « 0x0104011301e8 (6 bytes) 19:41:32.252 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:32.253 SERIAL » [ACK] (0x06) 19:41:32.255 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.273 SERIAL « 0x010700138100000369 (9 bytes) 19:41:32.276 DRIVER « [REQ] [SendData] [confirmation] callbackId: 129 transmitStatus: OK 19:41:32.274 SERIAL Buffer := 0x010700138100000369 (9 bytes) 19:41:32.275 SERIAL » [ACK] (0x06) 19:41:32.279 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.277 DRIVER ACK received from node for current transaction. RTT = 39.81 ms 19:41:32.286 SERIAL « 0x010d00040015078e03010100010068 (15 bytes) 19:41:32.292 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] payload: 0x0101000100 19:41:32.295 CNTRLR « [Node 021] received information for association group #1: maximum # of nodes: 1 currently assigned nodes: 1 currently assigned endpoints: 19:41:32.287 SERIAL Buffer := 0x010d00040015078e03010100010068 (15 bytes) 19:41:32.290 SERIAL » [ACK] (0x06) 19:41:32.295 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.300 SERIAL » 0x0109001330022602258254 (11 bytes) 19:41:32.293 DRIVER ACK already received, resolving transaction 19:41:32.294 DRIVER resuming send queue 19:41:32.300 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 130 └─[MultilevelSwitchCCGet] 19:41:32.301 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:32.296 CNTRLR » [Node 021] querying association group #2... 19:41:32.307 SERIAL « 0x010a000400300426070500e118 (13 bytes) 19:41:32.311 CNTRLR [Node 048] [~] [Multilevel Switch] switchType: 5 => 5 [Endpoint 0] [internal] 19:41:32.322 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 19:41:32.308 SERIAL Buffer := 0x010a000400300426070500e118 (13 bytes) 19:41:32.320 SERIAL » [ACK] (0x06) 19:41:32.321 SERIAL « [CAN] (0x18) 19:41:32.323 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.313 CNTRLR [Node 048] [Multilevel Switch] Left: metadata updated [Endpoint 0] 19:41:32.317 CNTRLR [Node 048] [Multilevel Switch] Right: metadata updated [Endpoint 0] 19:41:32.423 DRIVER » [Node 048] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 130 └─[MultilevelSwitchCCGet] 19:41:32.424 SERIAL » 0x0109001330022602258254 (11 bytes) 19:41:32.427 SERIAL « [ACK] (0x06) 19:41:32.429 DRIVER ACK received from controller for current transaction 19:41:32.430 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.434 SERIAL « 0x0104011301e8 (6 bytes) 19:41:32.436 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:32.435 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:32.435 SERIAL » [ACK] (0x06) 19:41:32.437 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.498 SERIAL « 0x01070013820000076e (9 bytes) 19:41:32.500 DRIVER « [REQ] [SendData] [confirmation] callbackId: 130 transmitStatus: OK 19:41:32.499 SERIAL Buffer := 0x01070013820000076e (9 bytes) 19:41:32.500 SERIAL » [ACK] (0x06) 19:41:32.503 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.501 DRIVER ACK received from node for current transaction. RTT = 79.26 ms 19:41:32.518 SERIAL « 0x010b00040030052603000000 (12 bytes) 19:41:32.519 SERIAL [incomplete] Buffer := 0x010b00040030052603000000 (12 bytes) 19:41:32.526 CNTRLR [Node 048] [+] [Multilevel Switch] targetValue: 0 [Endpoint 0] 19:41:32.541 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[MultilevelSwitchCCReport] payload: 0x000000 19:41:32.520 SERIAL « 0xe0 (1 bytes) 19:41:32.521 SERIAL Buffer := 0x010b00040030052603000000e0 (13 bytes) 19:41:32.540 SERIAL » [ACK] (0x06) 19:41:32.544 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.555 SERIAL » 0x010a001315038e02022583d8 (12 bytes) 19:41:32.532 CNTRLR [Node 048] [+] [Multilevel Switch] duration: [Duration: 0seconds] [Endpoint 0] 19:41:32.537 CNTRLR [Node 048] [+] [Multilevel Switch] currentValue: 0 [Endpoint 0] 19:41:32.546 CNTRLR [Node 048] [+] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true 19:41:32.543 DRIVER ACK already received, resolving transaction 19:41:32.543 DRIVER resuming send queue 19:41:32.549 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 131 └─[MultiChannelAssociationCCGet] payload: 0x02 19:41:32.686 SERIAL « [ACK] (0x06) 19:41:32.688 DRIVER ACK received from controller for current transaction 19:41:32.690 SERIAL « 0x060104011301e8 (7 bytes) 19:41:32.691 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:32.692 SERIAL » [ACK] (0x06) 19:41:32.695 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.693 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:32.725 CNTRLR [Node 048] BinarySwitchCC: doing a complete interview... 19:41:32.735 SERIAL « 0x010700138300000961 (9 bytes) 19:41:32.739 DRIVER « [REQ] [SendData] [confirmation] callbackId: 131 transmitStatus: OK 19:41:32.727 CNTRLR » [Node 048] querying Binary Switch state... 19:41:32.736 SERIAL Buffer := 0x010700138300000961 (9 bytes) 19:41:32.737 SERIAL » [ACK] (0x06) 19:41:32.743 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.740 DRIVER ACK received from node for current transaction. RTT = 192.13 ms 19:41:32.745 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:32.756 CNTRLR « [Node 021] received information for association group #2: maximum # of nodes: 16 currently assigned nodes: currently assigned endpoints: 19:41:32.757 CNTRLR » [Node 021] querying association group #3... 19:41:32.747 SERIAL « 0x010b00040015058e030210007f (13 bytes) 19:41:32.749 SERIAL Buffer := 0x010b00040015058e030210007f (13 bytes) 19:41:32.750 SERIAL » [ACK] (0x06) 19:41:32.755 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.767 SERIAL » 0x0109001330022502258451 (11 bytes) 19:41:32.752 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] payload: 0x021000 19:41:32.753 DRIVER ACK already received, resolving transaction 19:41:32.754 DRIVER resuming send queue 19:41:32.766 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 132 └─[BinarySwitchCCGet] 19:41:32.769 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:32.773 SERIAL « 0x010b00040015058e030210007f (13 bytes) 19:41:32.774 SERIAL Buffer := 0x010b00040015058e030210007f (13 bytes) 19:41:32.776 SERIAL » [ACK] (0x06) 19:41:32.778 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.784 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 19:41:32.783 SERIAL « [CAN] (0x18) 19:41:32.785 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.884 DRIVER » [Node 048] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 132 └─[BinarySwitchCCGet] 19:41:32.885 SERIAL » 0x0109001330022502258451 (11 bytes) 19:41:32.890 SERIAL « [ACK] (0x06) 19:41:32.891 DRIVER ACK received from controller for current transaction 19:41:32.892 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.895 SERIAL « 0x0104011301e8 (6 bytes) 19:41:32.897 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:32.896 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:32.897 SERIAL » [ACK] (0x06) 19:41:32.898 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.950 SERIAL « 0x01090004003003250300e7 (11 bytes) 19:41:32.954 CNTRLR [Node 048] [+] [Binary Switch] currentValue: false [Endpoint 0] 19:41:32.959 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[BinarySwitchCCReport] payload: 0x00 19:41:32.951 SERIAL Buffer := 0x01090004003003250300e7 (11 bytes) 19:41:32.957 SERIAL » [ACK] (0x06) 19:41:32.961 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:32.967 SERIAL » 0x010a001315038e02032585df (12 bytes) 19:41:32.962 CNTRLR « [Node 048] received Binary Switch state: current value: false 19:41:32.963 CNTRLR [Node 048] [+] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] 19:41:32.960 DRIVER ACK already received, resolving transaction 19:41:32.960 DRIVER resuming send queue 19:41:32.966 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 133 └─[MultiChannelAssociationCCGet] payload: 0x03 19:41:33.069 SERIAL « [ACK] (0x06) 19:41:33.070 DRIVER ACK received from controller for current transaction 19:41:33.072 SERIAL « 0x060104011301e8 (7 bytes) 19:41:33.073 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:33.075 SERIAL » [ACK] (0x06) 19:41:33.080 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.077 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:33.103 CNTRLR « [Node 041] received unsupported notification { "nodeId": 41, "ccId": "Notification", "ccCommand": "0x05", "alarmType": 0, "alarmLevel": 0 } 19:41:33.085 SERIAL « 0x0110000400290a7105000000ff070001084d (18 bytes) 19:41:33.087 SERIAL Buffer := 0x0110000400290a7105000000ff070001084d (18 bytes) 19:41:33.091 SERIAL » [ACK] (0x06) 19:41:33.105 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.110 CNTRLR [Node 048] ConfigurationCC: Loading configuration parameters from device confi g 19:41:33.113 CNTRLR [Node 048] [+] [Configuration] isParamInformationFromConfig: false [internal] 19:41:33.116 CNTRLR [Node 048] [Configuration] 1: metadata updated 19:41:33.123 CNTRLR [Node 048] [Configuration] 2: metadata updated 19:41:33.130 CNTRLR [Node 048] [Configuration] 3: metadata updated 19:41:33.137 CNTRLR [Node 048] [Configuration] 4: metadata updated 19:41:33.143 CNTRLR [Node 048] [Configuration] 5: metadata updated 19:41:33.148 CNTRLR [Node 048] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 19:41:33.150 CNTRLR » [Node 048] querying parameter #1 value... 19:41:33.158 DRIVER « [REQ] [SendData] [confirmation] callbackId: 133 transmitStatus: OK 19:41:33.154 SERIAL « 0x01070013850000056b (9 bytes) 19:41:33.155 SERIAL Buffer := 0x01070013850000056b (9 bytes) 19:41:33.156 SERIAL » [ACK] (0x06) 19:41:33.161 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.159 DRIVER ACK received from node for current transaction. RTT = 193.85 ms 19:41:33.163 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:33.174 CNTRLR « [Node 021] received information for association group #3: maximum # of nodes: 16 currently assigned nodes: currently assigned endpoints: 19:41:33.165 SERIAL « 0x010b00040015058e030310007e (13 bytes) 19:41:33.166 SERIAL Buffer := 0x010b00040015058e030310007e (13 bytes) 19:41:33.168 SERIAL » [ACK] (0x06) 19:41:33.173 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.181 SERIAL » 0x010a00133003700501258602 (12 bytes) 19:41:33.170 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] payload: 0x031000 19:41:33.171 DRIVER ACK already received, resolving transaction 19:41:33.171 DRIVER resuming send queue 19:41:33.179 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 134 └─[ConfigurationCCGet] payload: 0x01 19:41:33.182 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:33.175 CNTRLR » [Node 021] querying association group #4... 19:41:33.185 SERIAL « 0x010700138500000f61 (9 bytes) 19:41:33.186 SERIAL Buffer := 0x010700138500000f61 (9 bytes) 19:41:33.187 SERIAL » [ACK] (0x06) 19:41:33.190 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.188 DRIVER handling request SendData (19) 19:41:33.189 DRIVER no handlers registered! 19:41:33.193 SERIAL « [CAN] (0x18) 19:41:33.195 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.194 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 19:41:33.295 DRIVER » [Node 048] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 134 └─[ConfigurationCCGet] payload: 0x01 19:41:33.296 SERIAL » 0x010a00133003700501258602 (12 bytes) 19:41:33.301 SERIAL « [ACK] (0x06) 19:41:33.302 DRIVER ACK received from controller for current transaction 19:41:33.303 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.306 SERIAL « 0x0104011301e8 (6 bytes) 19:41:33.310 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:33.308 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:33.309 SERIAL » [ACK] (0x06) 19:41:33.311 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.323 SERIAL « 0x0110000400290a7105000000ff070001084d (18 bytes) 19:41:33.328 CNTRLR « [Node 041] received unsupported notification { "nodeId": 41, "ccId": "Notification", "ccCommand": "0x05", "alarmType": 0, "alarmLevel": 0 } 19:41:33.324 SERIAL Buffer := 0x0110000400290a7105000000ff070001084d (18 bytes) 19:41:33.326 SERIAL » [ACK] (0x06) 19:41:33.330 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.337 SERIAL « 0x010700138600000469 (9 bytes) 19:41:33.341 DRIVER « [REQ] [SendData] [confirmation] callbackId: 134 transmitStatus: OK 19:41:33.338 SERIAL Buffer := 0x010700138600000469 (9 bytes) 19:41:33.339 SERIAL » [ACK] (0x06) 19:41:33.343 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.342 DRIVER ACK received from node for current transaction. RTT = 47.91 ms 19:41:33.504 SERIAL « 0x010b00040030057006010100b3 (13 bytes) 19:41:33.509 CNTRLR [Node 048] [+] [Configuration] 1: 0 19:41:33.516 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x010100 19:41:33.505 SERIAL Buffer := 0x010b00040030057006010100b3 (13 bytes) 19:41:33.514 SERIAL » [ACK] (0x06) 19:41:33.521 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.528 SERIAL » 0x010a001315038e02042587da (12 bytes) 19:41:33.522 CNTRLR » [Node 048] querying parameter #2 value... 19:41:33.518 DRIVER ACK already received, resolving transaction 19:41:33.519 DRIVER resuming send queue 19:41:33.526 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 135 └─[MultiChannelAssociationCCGet] payload: 0x04 19:41:33.529 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:33.534 SERIAL « [ACK] (0x06) 19:41:33.535 DRIVER ACK received from controller for current transaction 19:41:33.537 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.541 SERIAL « 0x0104011301e8 (6 bytes) 19:41:33.544 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:33.542 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:33.543 SERIAL » [ACK] (0x06) 19:41:33.546 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.562 SERIAL « 0x01070013870000036f (9 bytes) 19:41:33.566 DRIVER « [REQ] [SendData] [confirmation] callbackId: 135 transmitStatus: OK 19:41:33.564 SERIAL Buffer := 0x01070013870000036f (9 bytes) 19:41:33.565 SERIAL » [ACK] (0x06) 19:41:33.570 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.568 DRIVER ACK received from node for current transaction. RTT = 42.61 ms 19:41:33.576 SERIAL « 0x010b00040015058e0304100079 (13 bytes) 19:41:33.581 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] payload: 0x041000 19:41:33.586 CNTRLR « [Node 021] received information for association group #4: maximum # of nodes: 16 currently assigned nodes: currently assigned endpoints: 19:41:33.577 SERIAL Buffer := 0x010b00040015058e0304100079 (13 bytes) 19:41:33.579 SERIAL » [ACK] (0x06) 19:41:33.585 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.594 SERIAL » 0x010a0013300370050225880f (12 bytes) 19:41:33.582 DRIVER ACK already received, resolving transaction 19:41:33.583 DRIVER resuming send queue 19:41:33.593 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 136 └─[ConfigurationCCGet] payload: 0x02 19:41:33.595 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:33.588 CNTRLR » [Node 021] querying association group #5... 19:41:33.601 SERIAL « [ACK] (0x06) 19:41:33.602 DRIVER ACK received from controller for current transaction 19:41:33.604 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.607 SERIAL « 0x0104011301e8 (6 bytes) 19:41:33.611 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:33.608 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:33.610 SERIAL » [ACK] (0x06) 19:41:33.613 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.701 SERIAL « 0x010700138800000a69 (9 bytes) 19:41:33.709 DRIVER « [REQ] [SendData] [confirmation] callbackId: 136 transmitStatus: OK 19:41:33.703 SERIAL Buffer := 0x010700138800000a69 (9 bytes) 19:41:33.704 SERIAL » [ACK] (0x06) 19:41:33.731 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.729 DRIVER ACK received from node for current transaction. RTT = 137.18 ms 19:41:33.771 SERIAL « 0x010b00040030057006020100b0 (13 bytes) 19:41:33.777 CNTRLR [Node 048] [+] [Configuration] 2: 0 19:41:33.784 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x020100 19:41:33.772 SERIAL Buffer := 0x010b00040030057006020100b0 (13 bytes) 19:41:33.782 SERIAL » [ACK] (0x06) 19:41:33.787 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.796 SERIAL » 0x010a001315038e02052589d5 (12 bytes) 19:41:33.789 CNTRLR » [Node 048] querying parameter #3 value... 19:41:33.785 DRIVER ACK already received, resolving transaction 19:41:33.786 DRIVER resuming send queue 19:41:33.795 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 137 └─[MultiChannelAssociationCCGet] payload: 0x05 19:41:33.798 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:33.805 SERIAL « [ACK] (0x06) 19:41:33.806 DRIVER ACK received from controller for current transaction 19:41:33.808 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.827 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:33.811 SERIAL « 0x0104011301e8 (6 bytes) 19:41:33.812 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:33.825 SERIAL » [ACK] (0x06) 19:41:33.831 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.840 DRIVER « [REQ] [SendData] [confirmation] callbackId: 137 transmitStatus: OK 19:41:33.835 SERIAL « 0x010700138900000361 (9 bytes) 19:41:33.836 SERIAL Buffer := 0x010700138900000361 (9 bytes) 19:41:33.838 SERIAL » [ACK] (0x06) 19:41:33.845 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.842 DRIVER ACK received from node for current transaction. RTT = 48.49 ms 19:41:33.872 CNTRLR « [Node 021] received information for association group #5: maximum # of nodes: 16 currently assigned nodes: currently assigned endpoints: 19:41:33.856 SERIAL « 0x010b00040015058e0305100078 (13 bytes) 19:41:33.857 SERIAL Buffer := 0x010b00040015058e0305100078 (13 bytes) 19:41:33.861 SERIAL » [ACK] (0x06) 19:41:33.869 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.900 SERIAL » 0x010a00133003700503258a0c (12 bytes) 19:41:33.864 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] payload: 0x051000 19:41:33.865 DRIVER ACK already received, resolving transaction 19:41:33.867 DRIVER resuming send queue 19:41:33.898 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 138 └─[ConfigurationCCGet] payload: 0x03 19:41:33.901 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:33.876 CNTRLR » [Node 021] supports Z-Wave+, assigning ourselves to the Lifeline group... 19:41:33.924 SERIAL « [ACK] (0x06) 19:41:33.925 DRIVER ACK received from controller for current transaction 19:41:33.926 SERIAL « 0x060104011301e8 (7 bytes) 19:41:33.927 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:33.928 SERIAL » [ACK] (0x06) 19:41:33.932 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:33.930 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:33.975 SERIAL « 0x010b00040030057006030101b0 (13 bytes) 19:41:33.980 CNTRLR [Node 048] [+] [Configuration] 3: 1 19:41:33.985 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x030101 19:41:33.976 SERIAL Buffer := 0x010b00040030057006030101b0 (13 bytes) 19:41:33.983 SERIAL » [ACK] (0x06) 19:41:33.989 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.001 SERIAL » 0x010d001315068e0101000100258bd3 (15 bytes) 19:41:33.991 CNTRLR » [Node 048] querying parameter #4 value... 19:41:33.987 DRIVER ACK already received, resolving transaction 19:41:33.988 DRIVER resuming send queue 19:41:33.999 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 139 └─[MultiChannelAssociationCCSet] payload: 0x01000100 19:41:34.002 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:34.027 SERIAL « [ACK] (0x06) 19:41:34.029 DRIVER ACK received from controller for current transaction 19:41:34.031 SERIAL « 0x060104011301e8 (7 bytes) 19:41:34.031 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:34.032 SERIAL » [ACK] (0x06) 19:41:34.038 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.037 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:34.051 SERIAL « 0x010700138b00000262 (9 bytes) 19:41:34.058 DRIVER « [REQ] [SendData] [final] callbackId: 139 transmitStatus: OK 19:41:34.070 CNTRLR [Node 021] [+] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true 19:41:34.053 SERIAL Buffer := 0x010700138b00000262 (9 bytes) 19:41:34.056 SERIAL » [ACK] (0x06) 19:41:34.065 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.077 SERIAL » 0x010a00133003700504258c0d (12 bytes) 19:41:34.061 DRIVER ACK already received, resolving transaction 19:41:34.063 DRIVER resuming send queue 19:41:34.076 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 140 └─[ConfigurationCCGet] payload: 0x04 19:41:34.080 SERIAL « 0x010700138b00000464 (9 bytes) 19:41:34.081 SERIAL Buffer := 0x010700138b00000464 (9 bytes) 19:41:34.082 SERIAL » [ACK] (0x06) 19:41:34.084 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.083 DRIVER handling request SendData (19) 19:41:34.084 DRIVER no handlers registered! 19:41:34.202 SERIAL « [CAN] (0x18) 19:41:34.204 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.203 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 19:41:34.214 CNTRLR [Node 048] [~] [Configuration] 3: 1 => 1 19:41:34.210 SERIAL « 0x010b00040030057006030101b0 (13 bytes) 19:41:34.211 SERIAL Buffer := 0x010b00040030057006030101b0 (13 bytes) 19:41:34.218 SERIAL » [ACK] (0x06) 19:41:34.221 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.220 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x030101 19:41:34.221 DRIVER no ACK received yet, remembering response 19:41:34.237 CNTRLR [Node 021] AssociationGroupInfoCC: doing a complete interview... 19:41:34.247 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:34.241 CNTRLR » [Node 021] Association group #1: Querying name... 19:41:34.303 DRIVER » [Node 048] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 140 └─[ConfigurationCCGet] payload: 0x04 19:41:34.304 SERIAL » 0x010a00133003700504258c0d (12 bytes) 19:41:34.310 SERIAL « [ACK] (0x06) 19:41:34.311 DRIVER ACK received from controller for current transaction 19:41:34.314 CNTRLR « [Node 048] Received unexpected ConfigurationReport (param = 3, value = 1) 19:41:34.313 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.324 SERIAL » 0x010a00131503590101258d01 (12 bytes) 19:41:34.312 DRIVER transaction finished, resolving... 19:41:34.323 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 141 └─[AssociationGroupInfoCCNameGet] payload: 0x01 19:41:34.317 CNTRLR » [Node 048] querying parameter #5 value... 19:41:34.326 SERIAL « 0x0104011301e8 (6 bytes) 19:41:34.326 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:34.327 SERIAL » [ACK] (0x06) 19:41:34.329 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.328 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:34.332 SERIAL « [CAN] (0x18) 19:41:34.334 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.333 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 19:41:34.336 SERIAL « 0x010700138c00000265 (9 bytes) 19:41:34.336 SERIAL Buffer := 0x010700138c00000265 (9 bytes) 19:41:34.337 SERIAL » [ACK] (0x06) 19:41:34.339 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.338 DRIVER handling request SendData (19) 19:41:34.338 DRIVER no handlers registered! 19:41:34.435 DRIVER » [Node 021] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 141 └─[AssociationGroupInfoCCNameGet] payload: 0x01 19:41:34.436 SERIAL » 0x010a00131503590101258d01 (12 bytes) 19:41:34.440 SERIAL « [ACK] (0x06) 19:41:34.441 DRIVER ACK received from controller for current transaction 19:41:34.441 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.445 SERIAL « 0x0104011301e8 (6 bytes) 19:41:34.447 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:34.446 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:34.447 SERIAL » [ACK] (0x06) 19:41:34.449 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.472 SERIAL « 0x010b00040030057006040101b7 (13 bytes) 19:41:34.478 CNTRLR [Node 048] [+] [Configuration] 4: 1 19:41:34.474 SERIAL Buffer := 0x010b00040030057006040101b7 (13 bytes) 19:41:34.482 SERIAL » [ACK] (0x06) 19:41:34.483 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.488 SERIAL « 0x010700138d00000462 (9 bytes) 19:41:34.492 DRIVER « [REQ] [SendData] [confirmation] callbackId: 141 transmitStatus: OK 19:41:34.490 SERIAL Buffer := 0x010700138d00000462 (9 bytes) 19:41:34.491 SERIAL » [ACK] (0x06) 19:41:34.500 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.494 DRIVER ACK received from node for current transaction. RTT = 59.62 ms 19:41:34.511 SERIAL « 0x0112000400150c590201086c6966656c696e65aa (20 bytes) 19:41:34.521 CNTRLR [Node 021] [+] [Association Group Information] name[1]: "lifeline" [internal] 19:41:34.524 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCNameReport] payload: 0x01086c6966656c696e65 19:41:34.513 SERIAL Buffer := 0x0112000400150c590201086c6966656c696e65aa (20 bytes) 19:41:34.522 SERIAL » [ACK] (0x06) 19:41:34.527 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.537 SERIAL » 0x010a00133003700505258e0e (12 bytes) 19:41:34.528 CNTRLR « [Node 021] Association group #1 has name "lifeline" 19:41:34.529 CNTRLR » [Node 021] Association group #1: Querying info... 19:41:34.525 DRIVER ACK already received, resolving transaction 19:41:34.526 DRIVER resuming send queue 19:41:34.536 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 142 └─[ConfigurationCCGet] payload: 0x05 19:41:34.538 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:34.545 SERIAL « [ACK] (0x06) 19:41:34.546 DRIVER ACK received from controller for current transaction 19:41:34.546 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.551 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:34.548 SERIAL « 0x0104011301e8 (6 bytes) 19:41:34.549 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:34.550 SERIAL » [ACK] (0x06) 19:41:34.552 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.564 SERIAL « 0x010700138e00000267 (9 bytes) 19:41:34.567 DRIVER « [REQ] [SendData] [confirmation] callbackId: 142 transmitStatus: OK 19:41:34.565 SERIAL Buffer := 0x010700138e00000267 (9 bytes) 19:41:34.566 SERIAL » [ACK] (0x06) 19:41:34.570 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.569 DRIVER ACK received from node for current transaction. RTT = 33.48 ms 19:41:34.581 SERIAL « 0x010b00040030057006050100b7 (13 bytes) 19:41:34.585 CNTRLR [Node 048] [+] [Configuration] 5: 0 19:41:34.590 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x050100 19:41:34.581 SERIAL Buffer := 0x010b00040030057006050100b7 (13 bytes) 19:41:34.588 SERIAL » [ACK] (0x06) 19:41:34.593 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.600 SERIAL » 0x010b0013150459030001258f07 (13 bytes) 19:41:34.595 CNTRLR [Node 048] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 19:41:34.591 DRIVER ACK already received, resolving transaction 19:41:34.592 DRIVER resuming send queue 19:41:34.599 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 143 └─[AssociationGroupInfoCCInfoGet] payload: 0x0001 19:41:34.698 SERIAL « [ACK] (0x06) 19:41:34.699 DRIVER ACK received from controller for current transaction 19:41:34.700 SERIAL « 0x060104011301e8 (7 bytes) 19:41:34.700 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:34.701 SERIAL » [ACK] (0x06) 19:41:34.703 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.702 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:34.713 SERIAL « 0x010700138f00000367 (9 bytes) 19:41:34.717 DRIVER « [REQ] [SendData] [confirmation] callbackId: 143 transmitStatus: OK 19:41:34.715 SERIAL Buffer := 0x010700138f00000367 (9 bytes) 19:41:34.716 SERIAL » [ACK] (0x06) 19:41:34.720 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.719 DRIVER ACK received from node for current transaction. RTT = 121.53 ms 19:41:34.726 SERIAL « 0x0110000400150a59040101000001000000a8 (18 bytes) 19:41:34.732 CNTRLR [Node 021] [+] [Association Group Information] info[1]: [object Obj [internal] ect] 19:41:34.735 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCInfoReport] payload: 0x0101000001000000 19:41:34.727 SERIAL Buffer := 0x0110000400150a59040101000001000000a8 (18 bytes) 19:41:34.733 SERIAL » [ACK] (0x06) 19:41:34.737 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.747 SERIAL » 0x010b001315045905800125909e (13 bytes) 19:41:34.740 CNTRLR « [Node 021] Received info for association group #1: info is dynamic: false profile: General: Lifeline 19:41:34.740 CNTRLR » [Node 021] Association group #1: Querying command list... 19:41:34.736 DRIVER ACK already received, resolving transaction 19:41:34.736 DRIVER resuming send queue 19:41:34.747 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 144 └─[AssociationGroupInfoCCCommandListGet] payload: 0x8001 19:41:34.748 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:34.752 SERIAL « [ACK] (0x06) 19:41:34.753 DRIVER ACK received from controller for current transaction 19:41:34.754 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.759 SERIAL « 0x0104011301e8 (6 bytes) 19:41:34.761 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:34.760 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:34.760 SERIAL » [ACK] (0x06) 19:41:34.762 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.781 SERIAL « 0x010700139000000378 (9 bytes) 19:41:34.785 DRIVER « [REQ] [SendData] [confirmation] callbackId: 144 transmitStatus: OK 19:41:34.783 SERIAL Buffer := 0x010700139000000378 (9 bytes) 19:41:34.784 SERIAL » [ACK] (0x06) 19:41:34.787 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.786 DRIVER ACK received from node for current transaction. RTT = 40.41 ms 19:41:34.795 SERIAL « 0x0112000400150c590601085a01260331 (16 bytes) 19:41:34.797 SERIAL [incomplete] Buffer := 0x0112000400150c590601085a01260331 (16 bytes) 19:41:34.812 CNTRLR [Node 021] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[1]: [object Map] 19:41:34.816 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCCommandListReport] payload: 0x01085a01260331053202 19:41:34.799 SERIAL « 0x053202dc (4 bytes) 19:41:34.801 SERIAL Buffer := 0x0112000400150c590601085a01260331053202dc (20 bytes) 19:41:34.814 SERIAL » [ACK] (0x06) 19:41:34.820 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.828 SERIAL » 0x010a0013150359010225911e (12 bytes) 19:41:34.822 CNTRLR » [Node 021] Association group #2: Querying name... 19:41:34.817 DRIVER ACK already received, resolving transaction 19:41:34.819 DRIVER resuming send queue 19:41:34.827 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 145 └─[AssociationGroupInfoCCNameGet] payload: 0x02 19:41:34.830 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:34.837 SERIAL « [ACK] (0x06) 19:41:34.838 DRIVER ACK received from controller for current transaction 19:41:34.839 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.846 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:34.842 SERIAL « 0x0104011301e8 (6 bytes) 19:41:34.843 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:34.844 SERIAL » [ACK] (0x06) 19:41:34.849 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.864 SERIAL « 0x010700139100000278 (9 bytes) 19:41:34.870 DRIVER « [REQ] [SendData] [confirmation] callbackId: 145 transmitStatus: OK 19:41:34.867 SERIAL Buffer := 0x010700139100000278 (9 bytes) 19:41:34.868 SERIAL » [ACK] (0x06) 19:41:34.873 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.871 DRIVER ACK received from node for current transaction. RTT = 45.27 ms 19:41:34.881 SERIAL « 0x011600040015105902020c42617369635365744b657931c3 (24 bytes) 19:41:34.888 CNTRLR [Node 021] [+] [Association Group Information] name[2]: "BasicSetKe [internal] y1" 19:41:34.890 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCNameReport] payload: 0x020c42617369635365744b657931 19:41:34.883 SERIAL Buffer := 0x011600040015105902020c42617369635365744b657931c3 (24 bytes) 19:41:34.889 SERIAL » [ACK] (0x06) 19:41:34.893 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.899 SERIAL » 0x010b0013150459030002259219 (13 bytes) 19:41:34.894 CNTRLR « [Node 021] Association group #2 has name "BasicSetKey1" 19:41:34.894 CNTRLR » [Node 021] Association group #2: Querying info... 19:41:34.891 DRIVER ACK already received, resolving transaction 19:41:34.892 DRIVER resuming send queue 19:41:34.898 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 146 └─[AssociationGroupInfoCCInfoGet] payload: 0x0002 19:41:34.900 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:34.905 SERIAL « [ACK] (0x06) 19:41:34.906 DRIVER ACK received from controller for current transaction 19:41:34.906 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.910 SERIAL « 0x0104011301e8 (6 bytes) 19:41:34.912 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:34.911 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:34.912 SERIAL » [ACK] (0x06) 19:41:34.913 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.932 SERIAL « 0x01070013920000037a (9 bytes) 19:41:34.936 DRIVER « [REQ] [SendData] [confirmation] callbackId: 146 transmitStatus: OK 19:41:34.934 SERIAL Buffer := 0x01070013920000037a (9 bytes) 19:41:34.935 SERIAL » [ACK] (0x06) 19:41:34.939 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.937 DRIVER ACK received from node for current transaction. RTT = 39.92 ms 19:41:34.947 SERIAL « 0x0110000400150a590401020020010000008b (18 bytes) 19:41:34.951 CNTRLR [Node 021] [+] [Association Group Information] info[2]: [object Obj [internal] ect] 19:41:34.954 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCInfoReport] payload: 0x0102002001000000 19:41:34.948 SERIAL Buffer := 0x0110000400150a590401020020010000008b (18 bytes) 19:41:34.952 SERIAL » [ACK] (0x06) 19:41:34.957 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.965 SERIAL » 0x010b001315045905800225939e (13 bytes) 19:41:34.958 CNTRLR « [Node 021] Received info for association group #2: info is dynamic: false profile: Control: Key 01 19:41:34.959 CNTRLR » [Node 021] Association group #2: Querying command list... 19:41:34.955 DRIVER ACK already received, resolving transaction 19:41:34.956 DRIVER resuming send queue 19:41:34.964 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 147 └─[AssociationGroupInfoCCCommandListGet] payload: 0x8002 19:41:34.966 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:34.971 SERIAL « [ACK] (0x06) 19:41:34.972 DRIVER ACK received from controller for current transaction 19:41:34.973 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:34.977 SERIAL « 0x0104011301e8 (6 bytes) 19:41:34.980 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:34.978 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:34.979 SERIAL » [ACK] (0x06) 19:41:34.986 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:35.044 SERIAL « 0x01070013930000037b (9 bytes) 19:41:35.050 DRIVER « [REQ] [SendData] [confirmation] callbackId: 147 transmitStatus: OK 19:41:35.045 SERIAL Buffer := 0x01070013930000037b (9 bytes) 19:41:35.047 SERIAL » [ACK] (0x06) 19:41:35.054 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:35.052 DRIVER ACK received from node for current transaction. RTT = 88.40 ms 19:41:35.077 CNTRLR [Node 021] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[2]: [object Map] 19:41:35.059 SERIAL « 0x010c00040015065906020220019a (14 bytes) 19:41:35.061 SERIAL Buffer := 0x010c00040015065906020220019a (14 bytes) 19:41:35.078 SERIAL » [ACK] (0x06) 19:41:35.086 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:35.097 SERIAL » 0x010a0013150359010325941a (12 bytes) 19:41:35.080 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCCommandListReport] payload: 0x02022001 19:41:35.083 DRIVER ACK already received, resolving transaction 19:41:35.084 DRIVER resuming send queue 19:41:35.096 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 148 └─[AssociationGroupInfoCCNameGet] payload: 0x03 19:41:35.099 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:35.089 CNTRLR » [Node 021] Association group #3: Querying name... 19:41:35.104 SERIAL « [ACK] (0x06) 19:41:35.105 DRIVER ACK received from controller for current transaction 19:41:35.106 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:35.110 SERIAL « 0x0104011301e8 (6 bytes) 19:41:35.113 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:35.111 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:35.112 SERIAL » [ACK] (0x06) 19:41:35.114 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:35.131 SERIAL « 0x01070013940000037c (9 bytes) 19:41:35.135 DRIVER « [REQ] [SendData] [confirmation] callbackId: 148 transmitStatus: OK 19:41:35.133 SERIAL Buffer := 0x01070013940000037c (9 bytes) 19:41:35.134 SERIAL » [ACK] (0x06) 19:41:35.138 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:35.137 DRIVER ACK received from node for current transaction. RTT = 41.84 ms 19:41:35.149 SERIAL « 0x011c00040015165902031244696d6d65725374617274 (22 bytes) 19:41:35.150 SERIAL [incomplete] Buffer := 0x011c00040015165902031244696d6d657253746172 (22 bytes) 74 19:41:35.163 CNTRLR [Node 021] [+] [Association Group Information] name[3]: "DimmerStar [internal] tSopKey1" 19:41:35.165 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCNameReport] payload: 0x031244696d6d65725374617274536f704b657931 19:41:35.160 SERIAL « 0x536f704b657931fe (8 bytes) 19:41:35.160 SERIAL Buffer := 0x011c00040015165902031244696d6d65725374617274536f704b657 (30 bytes) 931fe 19:41:35.164 SERIAL » [ACK] (0x06) 19:41:35.169 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:35.175 SERIAL » 0x010b001315045903000325951f (13 bytes) 19:41:35.170 CNTRLR « [Node 021] Association group #3 has name "DimmerStartSopKey1" 19:41:35.170 CNTRLR » [Node 021] Association group #3: Querying info... 19:41:35.167 DRIVER ACK already received, resolving transaction 19:41:35.167 DRIVER resuming send queue 19:41:35.174 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 149 └─[AssociationGroupInfoCCInfoGet] payload: 0x0003 19:41:35.176 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:35.181 SERIAL « [ACK] (0x06) 19:41:35.182 DRIVER ACK received from controller for current transaction 19:41:35.183 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:35.187 SERIAL « 0x0104011301e8 (6 bytes) 19:41:35.190 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:35.188 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:35.189 SERIAL » [ACK] (0x06) 19:41:35.192 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:35.207 SERIAL « 0x01070013950000037d (9 bytes) 19:41:35.213 DRIVER « [REQ] [SendData] [confirmation] callbackId: 149 transmitStatus: OK 19:41:35.211 SERIAL Buffer := 0x01070013950000037d (9 bytes) 19:41:35.212 SERIAL » [ACK] (0x06) 19:41:35.215 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:35.214 DRIVER ACK received from node for current transaction. RTT = 40.97 ms 19:41:35.223 SERIAL « 0x0110000400150a59040103002001 (14 bytes) 19:41:35.224 SERIAL [incomplete] Buffer := 0x0110000400150a59040103002001 (14 bytes) 19:41:35.229 CNTRLR [Node 021] [+] [Association Group Information] info[3]: [object Obj [internal] ect] 19:41:35.231 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCInfoReport] payload: 0x0103002001000000 19:41:35.226 SERIAL « 0x0000008a (4 bytes) 19:41:35.227 SERIAL Buffer := 0x0110000400150a590401030020010000008a (18 bytes) 19:41:35.230 SERIAL » [ACK] (0x06) 19:41:35.234 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:35.234 CNTRLR « [Node 021] Received info for association group #3: info is dynamic: false profile: Control: Key 01 19:41:35.235 CNTRLR » [Node 021] Association group #3: Querying command list... 19:41:35.232 DRIVER ACK already received, resolving transaction 19:41:35.233 DRIVER resuming send queue 19:41:35.238 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 150 └─[AssociationGroupInfoCCCommandListGet] payload: 0x8003 19:41:35.240 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:35.239 SERIAL » 0x010b001315045905800325969a (13 bytes) 19:41:35.243 SERIAL « [ACK] (0x06) 19:41:35.244 DRIVER ACK received from controller for current transaction 19:41:35.245 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:35.250 SERIAL « 0x0104011301e8 (6 bytes) 19:41:35.253 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:35.251 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:35.252 SERIAL » [ACK] (0x06) 19:41:35.254 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:35.271 SERIAL « 0x01070013960000037e (9 bytes) 19:41:35.274 DRIVER « [REQ] [SendData] [confirmation] callbackId: 150 transmitStatus: OK 19:41:35.272 SERIAL Buffer := 0x01070013960000037e (9 bytes) 19:41:35.273 SERIAL » [ACK] (0x06) 19:41:35.277 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:35.275 DRIVER ACK received from node for current transaction. RTT = 37.87 ms 19:41:35.285 SERIAL « 0x010e00040015085906030426 (12 bytes) 19:41:35.291 CNTRLR [Node 021] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[3]: [object Map] 19:41:35.286 SERIAL [incomplete] Buffer := 0x010e00040015085906030426 (12 bytes) 19:41:35.287 SERIAL « 0x042605b1 (4 bytes) 19:41:35.288 SERIAL Buffer := 0x010e00040015085906030426042605b1 (16 bytes) 19:41:35.292 SERIAL » [ACK] (0x06) 19:41:35.295 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:35.300 SERIAL » 0x010a0013150359010425971e (12 bytes) 19:41:35.293 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCCommandListReport] payload: 0x030426042605 19:41:35.296 CNTRLR » [Node 021] Association group #4: Querying name... 19:41:35.294 DRIVER ACK already received, resolving transaction 19:41:35.295 DRIVER resuming send queue 19:41:35.299 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 151 └─[AssociationGroupInfoCCNameGet] payload: 0x04 19:41:35.301 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:36.197 SERIAL « [ACK] (0x06) 19:41:36.199 DRIVER ACK received from controller for current transaction 19:41:36.216 CNTRLR [Node 048] AssociationCC: skipping interview because Multi Channel Association is supported... 19:41:36.201 SERIAL « 0x060104011301e8 (7 bytes) 19:41:36.202 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:36.203 SERIAL » [ACK] (0x06) 19:41:36.209 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.207 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:36.218 CNTRLR [Node 048] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 19:41:36.220 CNTRLR [Node 048] MultiChannelAssociationCC: doing a complete interview... 19:41:36.221 CNTRLR » [Node 048] querying number of association groups... 19:41:36.225 SERIAL « 0x01070013970000037f (9 bytes) 19:41:36.225 SERIAL Buffer := 0x01070013970000037f (9 bytes) 19:41:36.226 SERIAL » [ACK] (0x06) 19:41:36.230 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.224 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:36.228 DRIVER « [REQ] [SendData] [confirmation] callbackId: 151 transmitStatus: OK 19:41:36.229 DRIVER ACK received from node for current transaction. RTT = 930.07 ms 19:41:36.234 SERIAL « 0x011700040015115902040d44696d6d65725365744b657931a4 (25 bytes) 19:41:36.237 CNTRLR [Node 021] [+] [Association Group Information] name[4]: "DimmerSetK [internal] ey1" 19:41:36.240 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCNameReport] payload: 0x040d44696d6d65725365744b657931 19:41:36.235 SERIAL Buffer := 0x011700040015115902040d44696d6d65725365744b657931a4 (25 bytes) 19:41:36.238 SERIAL » [ACK] (0x06) 19:41:36.243 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.249 SERIAL » 0x0109001330028e052598e1 (11 bytes) 19:41:36.243 CNTRLR « [Node 021] Association group #4 has name "DimmerSetKey1" 19:41:36.244 CNTRLR » [Node 021] Association group #4: Querying info... 19:41:36.241 DRIVER ACK already received, resolving transaction 19:41:36.242 DRIVER resuming send queue 19:41:36.248 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 152 └─[MultiChannelAssociationCCSupportedGroupingsGet] 19:41:36.250 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:36.254 SERIAL « [ACK] (0x06) 19:41:36.255 DRIVER ACK received from controller for current transaction 19:41:36.256 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.261 SERIAL « 0x0104011301e8 (6 bytes) 19:41:36.265 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:36.262 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:36.263 SERIAL » [ACK] (0x06) 19:41:36.267 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.276 SERIAL « 0x010700139800000271 (9 bytes) 19:41:36.279 DRIVER « [REQ] [SendData] [confirmation] callbackId: 152 transmitStatus: OK 19:41:36.277 SERIAL Buffer := 0x010700139800000271 (9 bytes) 19:41:36.277 SERIAL » [ACK] (0x06) 19:41:36.283 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.280 DRIVER ACK received from node for current transaction. RTT = 33.36 ms 19:41:36.359 SERIAL « 0x010900040030038e06024b (11 bytes) 19:41:36.363 CNTRLR [Node 048] [+] [Multi Channel Association] groupCount: [Endpoint 0] [internal] 2 19:41:36.365 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCSupportedGroupingsReport] payload: 0x02 19:41:36.360 SERIAL Buffer := 0x010900040030038e06024b (11 bytes) 19:41:36.364 SERIAL » [ACK] (0x06) 19:41:36.368 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.374 SERIAL » 0x010b0013150459030004259914 (13 bytes) 19:41:36.368 CNTRLR « [Node 048] supports 2 association groups 19:41:36.369 CNTRLR » [Node 048] querying association group #1... 19:41:36.366 DRIVER ACK already received, resolving transaction 19:41:36.367 DRIVER resuming send queue 19:41:36.373 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 153 └─[AssociationGroupInfoCCInfoGet] payload: 0x0004 19:41:36.375 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:36.477 SERIAL « [ACK] (0x06) 19:41:36.478 DRIVER ACK received from controller for current transaction 19:41:36.479 SERIAL « 0x060104011301e8 (7 bytes) 19:41:36.479 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:36.480 SERIAL » [ACK] (0x06) 19:41:36.483 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.481 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:36.498 CNTRLR [Node 048] [~] [Multi Channel Association] groupCount: [Endpoint 0] [internal] 2 => 2 19:41:36.493 SERIAL « 0x010900040030038e06024b (11 bytes) 19:41:36.494 SERIAL Buffer := 0x010900040030038e06024b (11 bytes) 19:41:36.499 SERIAL » [ACK] (0x06) 19:41:36.501 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.508 DRIVER « [REQ] [SendData] [confirmation] callbackId: 153 transmitStatus: OK 19:41:36.504 SERIAL « 0x010700139900000476 (9 bytes) 19:41:36.505 SERIAL Buffer := 0x010700139900000476 (9 bytes) 19:41:36.506 SERIAL » [ACK] (0x06) 19:41:36.511 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.509 DRIVER ACK received from node for current transaction. RTT = 137.02 ms 19:41:36.515 SERIAL « 0x0110000400150a590401040020010000008d (18 bytes) 19:41:36.519 CNTRLR [Node 021] [+] [Association Group Information] info[4]: [object Obj [internal] ect] 19:41:36.524 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCInfoReport] payload: 0x0104002001000000 19:41:36.516 SERIAL Buffer := 0x0110000400150a590401040020010000008d (18 bytes) 19:41:36.521 SERIAL » [ACK] (0x06) 19:41:36.530 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.540 SERIAL » 0x010a001330038e0201259ae7 (12 bytes) 19:41:36.531 CNTRLR « [Node 021] Received info for association group #4: info is dynamic: false profile: Control: Key 01 19:41:36.533 CNTRLR » [Node 021] Association group #4: Querying command list... 19:41:36.526 DRIVER ACK already received, resolving transaction 19:41:36.527 DRIVER resuming send queue 19:41:36.539 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 154 └─[MultiChannelAssociationCCGet] payload: 0x01 19:41:36.542 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:36.546 SERIAL « [ACK] (0x06) 19:41:36.547 DRIVER ACK received from controller for current transaction 19:41:36.548 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.552 SERIAL « 0x0104011301e8 (6 bytes) 19:41:36.555 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:36.553 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:36.554 SERIAL » [ACK] (0x06) 19:41:36.556 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.569 SERIAL « 0x010700139a00000273 (9 bytes) 19:41:36.572 DRIVER « [REQ] [SendData] [confirmation] callbackId: 154 transmitStatus: OK 19:41:36.570 SERIAL Buffer := 0x010700139a00000273 (9 bytes) 19:41:36.571 SERIAL » [ACK] (0x06) 19:41:36.574 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.573 DRIVER ACK received from node for current transaction. RTT = 35.79 ms 19:41:36.664 SERIAL « 0x010e00040030088e0301050000010045 (16 bytes) 19:41:36.672 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] payload: 0x010500000100 19:41:36.682 CNTRLR « [Node 048] received information for association group #1: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 1:0 19:41:36.666 SERIAL Buffer := 0x010e00040030088e0301050000010045 (16 bytes) 19:41:36.669 SERIAL » [ACK] (0x06) 19:41:36.679 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.692 SERIAL » 0x010b0013150459058004259b90 (13 bytes) 19:41:36.673 DRIVER ACK already received, resolving transaction 19:41:36.676 DRIVER resuming send queue 19:41:36.690 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 155 └─[AssociationGroupInfoCCCommandListGet] payload: 0x8004 19:41:36.693 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:36.684 CNTRLR » [Node 048] querying association group #2... 19:41:36.699 SERIAL « [ACK] (0x06) 19:41:36.701 DRIVER ACK received from controller for current transaction 19:41:36.702 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.713 SERIAL « 0x0104011301e8 (6 bytes) 19:41:36.718 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:36.715 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:36.716 SERIAL » [ACK] (0x06) 19:41:36.719 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.728 SERIAL « 0x010700139b00000272 (9 bytes) 19:41:36.734 DRIVER « [REQ] [SendData] [confirmation] callbackId: 155 transmitStatus: OK 19:41:36.730 SERIAL Buffer := 0x010700139b00000272 (9 bytes) 19:41:36.732 SERIAL » [ACK] (0x06) 19:41:36.739 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.736 DRIVER ACK received from node for current transaction. RTT = 46.91 ms 19:41:36.751 CNTRLR [Node 021] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[4]: [object Map] 19:41:36.744 SERIAL « 0x010c00040015065906040226019a (14 bytes) 19:41:36.746 SERIAL Buffer := 0x010c00040015065906040226019a (14 bytes) 19:41:36.753 SERIAL » [ACK] (0x06) 19:41:36.757 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.754 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCCommandListReport] payload: 0x04022601 19:41:36.755 DRIVER ACK already received, resolving transaction 19:41:36.756 DRIVER resuming send queue 19:41:36.758 CNTRLR » [Node 021] Association group #5: Querying name... 19:41:36.764 SERIAL » 0x010a001330038e0202259ce2 (12 bytes) 19:41:36.763 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 156 └─[MultiChannelAssociationCCGet] payload: 0x02 19:41:36.765 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:36.772 SERIAL « [ACK] (0x06) 19:41:36.773 DRIVER ACK received from controller for current transaction 19:41:36.774 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.779 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:36.776 SERIAL « 0x0104011301e8 (6 bytes) 19:41:36.777 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:36.778 SERIAL » [ACK] (0x06) 19:41:36.781 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.860 SERIAL « 0x010700139c0000097e (9 bytes) 19:41:36.864 DRIVER « [REQ] [SendData] [confirmation] callbackId: 156 transmitStatus: OK 19:41:36.861 SERIAL Buffer := 0x010700139c0000097e (9 bytes) 19:41:36.862 SERIAL » [ACK] (0x06) 19:41:36.868 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.866 DRIVER ACK received from node for current transaction. RTT = 104.20 ms 19:41:36.885 SERIAL « 0x010b00040030058e030205004f (13 bytes) 19:41:36.889 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] payload: 0x020500 19:41:36.894 CNTRLR « [Node 048] received information for association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 19:41:36.886 SERIAL Buffer := 0x010b00040030058e030205004f (13 bytes) 19:41:36.887 SERIAL » [ACK] (0x06) 19:41:36.893 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.903 SERIAL » 0x010a00131503590105259d15 (12 bytes) 19:41:36.891 DRIVER ACK already received, resolving transaction 19:41:36.892 DRIVER resuming send queue 19:41:36.902 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 157 └─[AssociationGroupInfoCCNameGet] payload: 0x05 19:41:36.905 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:36.896 CNTRLR » [Node 048] supports Z-Wave+, assigning ourselves to the Lifeline group... 19:41:36.910 SERIAL « [ACK] (0x06) 19:41:36.911 DRIVER ACK received from controller for current transaction 19:41:36.913 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.919 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:36.915 SERIAL « 0x0104011301e8 (6 bytes) 19:41:36.917 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:36.918 SERIAL » [ACK] (0x06) 19:41:36.921 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.937 SERIAL « 0x010700139d00000274 (9 bytes) 19:41:36.941 DRIVER « [REQ] [SendData] [confirmation] callbackId: 157 transmitStatus: OK 19:41:36.938 SERIAL Buffer := 0x010700139d00000274 (9 bytes) 19:41:36.939 SERIAL » [ACK] (0x06) 19:41:36.943 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.942 DRIVER ACK received from node for current transaction. RTT = 40.46 ms 19:41:36.952 SERIAL « 0x0114000400150e5902050a54656d70 (15 bytes) 19:41:36.953 SERIAL [incomplete] Buffer := 0x0114000400150e5902050a54656d70 (15 bytes) 19:41:36.959 CNTRLR [Node 021] [+] [Association Group Information] name[5]: "TempReport [internal] " 19:41:36.962 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCNameReport] payload: 0x050a54656d705265706f7274 19:41:36.955 SERIAL « 0x5265706f7274a2 (7 bytes) 19:41:36.956 SERIAL Buffer := 0x0114000400150e5902050a54656d705265706f7274a2 (22 bytes) 19:41:36.960 SERIAL » [ACK] (0x06) 19:41:36.966 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.974 SERIAL » 0x010d001330068e0101000100259ee3 (15 bytes) 19:41:36.967 CNTRLR « [Node 021] Association group #5 has name "TempReport" 19:41:36.968 CNTRLR » [Node 021] Association group #5: Querying info... 19:41:36.963 DRIVER ACK already received, resolving transaction 19:41:36.964 DRIVER resuming send queue 19:41:36.973 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 158 └─[MultiChannelAssociationCCSet] payload: 0x01000100 19:41:36.975 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:36.980 SERIAL « [ACK] (0x06) 19:41:36.981 DRIVER ACK received from controller for current transaction 19:41:36.982 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:36.986 SERIAL « 0x0104011301e8 (6 bytes) 19:41:36.989 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:36.987 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:36.988 SERIAL » [ACK] (0x06) 19:41:36.990 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.080 SERIAL « 0x010700139e0000 (7 bytes) 19:41:37.081 SERIAL [incomplete] Buffer := 0x010700139e0000 (7 bytes) 19:41:37.085 DRIVER « [REQ] [SendData] [final] callbackId: 158 transmitStatus: OK 19:41:37.089 CNTRLR [Node 048] [+] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true 19:41:37.083 SERIAL « 0x0a7f (2 bytes) 19:41:37.083 SERIAL Buffer := 0x010700139e00000a7f (9 bytes) 19:41:37.084 SERIAL » [ACK] (0x06) 19:41:37.087 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.092 SERIAL » 0x010b0013150459030005259f13 (13 bytes) 19:41:37.086 DRIVER ACK already received, resolving transaction 19:41:37.086 DRIVER resuming send queue 19:41:37.091 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 159 └─[AssociationGroupInfoCCInfoGet] payload: 0x0005 19:41:37.190 SERIAL « [ACK] (0x06) 19:41:37.191 DRIVER ACK received from controller for current transaction 19:41:37.192 SERIAL « 0x060104011301e8 (7 bytes) 19:41:37.192 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:37.193 SERIAL » [ACK] (0x06) 19:41:37.195 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.194 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:37.197 SERIAL « 0x010700139f0000 (7 bytes) 19:41:37.197 SERIAL [incomplete] Buffer := 0x010700139f0000 (7 bytes) 19:41:37.200 CNTRLR [Node 048] AssociationGroupInfoCC: doing a complete interview... 19:41:37.206 DRIVER « [REQ] [SendData] [confirmation] callbackId: 159 transmitStatus: OK 19:41:37.204 SERIAL « 0x0276 (2 bytes) 19:41:37.204 SERIAL Buffer := 0x010700139f00000276 (9 bytes) 19:41:37.205 SERIAL » [ACK] (0x06) 19:41:37.208 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.202 CNTRLR » [Node 048] Association group #1: Querying name... 19:41:37.207 DRIVER ACK received from node for current transaction. RTT = 116.16 ms 19:41:37.209 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:37.211 SERIAL « 0x0110000400150a590401050031010000009d (18 bytes) 19:41:37.214 CNTRLR [Node 021] [+] [Association Group Information] info[5]: [object Obj [internal] ect] 19:41:37.219 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCInfoReport] payload: 0x0105003101000000 19:41:37.212 SERIAL Buffer := 0x0110000400150a590401050031010000009d (18 bytes) 19:41:37.215 SERIAL » [ACK] (0x06) 19:41:37.222 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.229 SERIAL » 0x010a0013300359010125a009 (12 bytes) 19:41:37.223 CNTRLR « [Node 021] Received info for association group #5: info is dynamic: false profile: Sensor: Air temperature 19:41:37.224 CNTRLR » [Node 021] Association group #5: Querying command list... 19:41:37.220 DRIVER ACK already received, resolving transaction 19:41:37.221 DRIVER resuming send queue 19:41:37.228 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 160 └─[AssociationGroupInfoCCNameGet] payload: 0x01 19:41:37.231 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:37.235 SERIAL « [ACK] (0x06) 19:41:37.237 DRIVER ACK received from controller for current transaction 19:41:37.238 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.242 SERIAL « 0x0104011301e8 (6 bytes) 19:41:37.245 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:37.243 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:37.244 SERIAL » [ACK] (0x06) 19:41:37.246 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.275 SERIAL « 0x0112000400300c590201084c6966656c696e65af (20 bytes) 19:41:37.280 CNTRLR [Node 048] [+] [Association Group Information] name[1]: "Lifeline" [internal] 19:41:37.284 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCNameReport] payload: 0x01084c6966656c696e65 19:41:37.277 SERIAL Buffer := 0x0112000400300c590201084c6966656c696e65af (20 bytes) 19:41:37.282 SERIAL » [ACK] (0x06) 19:41:37.290 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.299 SERIAL » 0x010b001315045905800525a1ab (13 bytes) 19:41:37.291 CNTRLR « [Node 048] Association group #1 has name "Lifeline" 19:41:37.292 CNTRLR » [Node 048] Association group #1: Querying info... 19:41:37.286 DRIVER ACK already received, resolving transaction 19:41:37.287 DRIVER resuming send queue 19:41:37.298 DRIVER » [Node 021] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 161 └─[AssociationGroupInfoCCCommandListGet] payload: 0x8005 19:41:37.301 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:37.306 SERIAL « [ACK] (0x06) 19:41:37.307 DRIVER ACK received from controller for current transaction 19:41:37.308 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.312 SERIAL « 0x0104011301e8 (6 bytes) 19:41:37.316 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:37.313 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:37.314 SERIAL » [ACK] (0x06) 19:41:37.318 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.328 SERIAL « 0x01070013a100000248 (9 bytes) 19:41:37.332 DRIVER « [REQ] [SendData] [confirmation] callbackId: 161 transmitStatus: OK 19:41:37.329 SERIAL Buffer := 0x01070013a100000248 (9 bytes) 19:41:37.330 SERIAL » [ACK] (0x06) 19:41:37.335 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.333 DRIVER ACK received from node for current transaction. RTT = 36.39 ms 19:41:37.363 SERIAL « 0x010c000400150659060502310588 (14 bytes) 19:41:37.368 CNTRLR [Node 021] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[5]: [object Map] 19:41:37.373 DRIVER « [Node 021] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCCommandListReport] payload: 0x05023105 19:41:37.364 SERIAL Buffer := 0x010c000400150659060502310588 (14 bytes) 19:41:37.370 SERIAL » [ACK] (0x06) 19:41:37.376 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.383 SERIAL » 0x010b001330045903000125a20f (13 bytes) 19:41:37.378 CNTRLR [Node 021] [+] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true 19:41:37.374 DRIVER ACK already received, resolving transaction 19:41:37.375 DRIVER resuming send queue 19:41:37.381 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 162 └─[AssociationGroupInfoCCInfoGet] payload: 0x0001 19:41:37.480 SERIAL « 0x01070013a10000084218 (10 bytes) 19:41:37.482 DRIVER handling request SendData (19) 19:41:37.481 SERIAL Buffer := 0x01070013a10000084218 (10 bytes) 19:41:37.481 SERIAL » [ACK] (0x06) 19:41:37.484 SERIAL « [CAN] (0x18) 19:41:37.485 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.483 DRIVER no handlers registered! 19:41:37.485 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 19:41:37.497 CNTRLR [Node 021] [~] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[5]: [object Map] => [object Map] 19:41:37.492 SERIAL « 0x010c000400150659060502310588 (14 bytes) 19:41:37.493 SERIAL Buffer := 0x010c000400150659060502310588 (14 bytes) 19:41:37.498 SERIAL » [ACK] (0x06) 19:41:37.500 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.504 CNTRLR [Node 021] Interview stage completed: CommandClasses 19:41:37.508 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:37.505 CNTRLR [Node 021] Interview stage completed: OverwriteConfig 19:41:37.506 CNTRLR » [Node 021] requesting node neighbors... 19:41:37.515 SERIAL « 0x011200040030 (6 bytes) 19:41:37.516 SERIAL [incomplete] Buffer := 0x011200040030 (6 bytes) 19:41:37.521 CNTRLR [Node 048] [~] [Association Group Information] name[1]: "Lifeline" [internal] => "Lifeline" 19:41:37.517 SERIAL « 0x0c590201084c6966656c696e65af (14 bytes) 19:41:37.518 SERIAL Buffer := 0x0112000400300c590201084c6966656c696e65af (20 bytes) 19:41:37.522 SERIAL » [ACK] (0x06) 19:41:37.523 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.585 DRIVER » [Node 048] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 162 └─[AssociationGroupInfoCCInfoGet] payload: 0x0001 19:41:37.586 SERIAL » 0x010b001330045903000125a20f (13 bytes) 19:41:37.590 SERIAL « [ACK] (0x06) 19:41:37.591 DRIVER ACK received from controller for current transaction 19:41:37.591 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.596 SERIAL « 0x0104011301e8 (6 bytes) 19:41:37.599 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:37.597 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:37.597 SERIAL » [ACK] (0x06) 19:41:37.600 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.613 SERIAL « 0x01070013a20000024b (9 bytes) 19:41:37.615 DRIVER « [REQ] [SendData] [confirmation] callbackId: 162 transmitStatus: OK 19:41:37.614 SERIAL Buffer := 0x01070013a20000024b (9 bytes) 19:41:37.614 SERIAL » [ACK] (0x06) 19:41:37.617 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.616 DRIVER ACK received from node for current transaction. RTT = 31.75 ms 19:41:37.756 SERIAL « 0x0110000400300a590401010000010000008d (18 bytes) 19:41:37.760 CNTRLR [Node 048] [+] [Association Group Information] info[1]: [object Obj [internal] ect] 19:41:37.762 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCInfoReport] payload: 0x0101000001000000 19:41:37.757 SERIAL Buffer := 0x0110000400300a590401010000010000008d (18 bytes) 19:41:37.761 SERIAL » [ACK] (0x06) 19:41:37.764 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.771 SERIAL » 0x01070080150000006d (9 bytes) 19:41:37.765 CNTRLR « [Node 048] Received info for association group #1: info is dynamic: false profile: General: Lifeline 19:41:37.766 CNTRLR » [Node 048] Association group #1: Querying command list... 19:41:37.763 DRIVER ACK already received, resolving transaction 19:41:37.764 DRIVER resuming send queue 19:41:37.770 DRIVER » [Node 021] [REQ] [GetRoutingInfo] [P: Controller] removeNonRepeaters: false removeBadLinks: false 19:41:37.772 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:37.777 SERIAL « [ACK] (0x06) 19:41:37.778 DRIVER ACK received from controller for current transaction 19:41:37.779 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.783 DRIVER « [RES] [GetRoutingInfo] [final] node ids: 1, 11, 14, 17, 18, 19, 23, 24, 30, 34, 48 19:41:37.786 CNTRLR « [Node 021] node neighbors received: 1, 11, 14, 17, 18, 19, 23, 24, 30, 34, 4 8 19:41:37.780 SERIAL « 0x012001800124c7200280000000000000000000000000000000000000000000000 (34 bytes) 01e 19:41:37.781 SERIAL Buffer := 0x012001800124c720028000000000000000000000000000000000000 (34 bytes) 000000000001e 19:41:37.782 SERIAL » [ACK] (0x06) 19:41:37.787 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.798 SERIAL » 0x010b001330045905800125a388 (13 bytes) 19:41:37.784 DRIVER ACK already received, resolving transaction 19:41:37.785 DRIVER resuming send queue 19:41:37.797 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 163 └─[AssociationGroupInfoCCCommandListGet] payload: 0x8001 19:41:37.787 CNTRLR [Node 021] Interview stage completed: Neighbors 19:41:37.788 CNTRLR [Node 021] Interview completed 19:41:37.789 CNTRLR [Node 021] The node is ready to be used 19:41:37.794 CNTRLR [Node 021] node is ready 19:41:37.810 SERIAL « [ACK] (0x06) 19:41:37.812 DRIVER ACK received from controller for current transaction 19:41:37.814 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.819 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:37.816 SERIAL « 0x0104011301e8 (6 bytes) 19:41:37.817 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:37.818 SERIAL » [ACK] (0x06) 19:41:37.821 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.930 SERIAL « 0x01070013a300000b43 (9 bytes) 19:41:37.934 DRIVER « [REQ] [SendData] [confirmation] callbackId: 163 transmitStatus: OK 19:41:37.931 SERIAL Buffer := 0x01070013a300000b43 (9 bytes) 19:41:37.932 SERIAL » [ACK] (0x06) 19:41:37.936 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:37.935 DRIVER ACK received from node for current transaction. RTT = 137.95 ms 19:41:38.054 SERIAL « 0x010e00040030085906010426035a01e9 (16 bytes) 19:41:38.058 CNTRLR [Node 048] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[1]: [object Map] 19:41:38.060 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCCommandListReport] payload: 0x010426035a01 19:41:38.055 SERIAL Buffer := 0x010e00040030085906010426035a01e9 (16 bytes) 19:41:38.059 SERIAL » [ACK] (0x06) 19:41:38.063 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:38.069 SERIAL » 0x010a0013300359010225a40e (12 bytes) 19:41:38.063 CNTRLR » [Node 048] Association group #2: Querying name... 19:41:38.061 DRIVER ACK already received, resolving transaction 19:41:38.062 DRIVER resuming send queue 19:41:38.068 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 164 └─[AssociationGroupInfoCCNameGet] payload: 0x02 19:41:38.069 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:38.074 SERIAL « [ACK] (0x06) 19:41:38.076 DRIVER ACK received from controller for current transaction 19:41:38.077 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:38.079 SERIAL « 0x0104011301e8 (6 bytes) 19:41:38.094 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:38.081 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:38.081 SERIAL » [ACK] (0x06) 19:41:38.095 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:38.109 SERIAL « 0x01070013a40000024d (9 bytes) 19:41:38.113 DRIVER « [REQ] [SendData] [confirmation] callbackId: 164 transmitStatus: OK 19:41:38.110 SERIAL Buffer := 0x01070013a40000024d (9 bytes) 19:41:38.111 SERIAL » [ACK] (0x06) 19:41:38.115 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:38.114 DRIVER ACK received from node for current transaction. RTT = 46.84 ms 19:41:38.136 SERIAL « 0x010a0004003004590202009c (12 bytes) 19:41:38.139 CNTRLR [Node 048] [+] [Association Group Information] name[2]: "" [internal] 19:41:38.142 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCNameReport] payload: 0x0200 19:41:38.137 SERIAL Buffer := 0x010a0004003004590202009c (12 bytes) 19:41:38.140 SERIAL » [ACK] (0x06) 19:41:38.145 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:38.154 SERIAL » 0x010b001330045903000225a50b (13 bytes) 19:41:38.146 CNTRLR « [Node 048] Association group #2 has name "" 19:41:38.147 CNTRLR » [Node 048] Association group #2: Querying info... 19:41:38.143 DRIVER ACK already received, resolving transaction 19:41:38.144 DRIVER resuming send queue 19:41:38.152 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 165 └─[AssociationGroupInfoCCInfoGet] payload: 0x0002 19:41:38.155 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:38.166 SERIAL « 0x010a0004003004590202009c18 (13 bytes) 19:41:38.171 CNTRLR [Node 048] [~] [Association Group Information] name[2]: "" => "" [internal] 19:41:38.177 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 19:41:38.167 SERIAL Buffer := 0x010a0004003004590202009c18 (13 bytes) 19:41:38.173 SERIAL » [ACK] (0x06) 19:41:38.176 SERIAL « [CAN] (0x18) 19:41:38.178 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:38.277 DRIVER » [Node 048] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 165 └─[AssociationGroupInfoCCInfoGet] payload: 0x0002 19:41:38.278 SERIAL » 0x010b001330045903000225a50b (13 bytes) 19:41:38.283 SERIAL « [ACK] (0x06) 19:41:38.284 DRIVER ACK received from controller for current transaction 19:41:38.284 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:38.288 SERIAL « 0x0104011301e8 (6 bytes) 19:41:38.290 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:38.289 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:38.290 SERIAL » [ACK] (0x06) 19:41:38.291 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:38.321 SERIAL « 0x0110000400300a590401 (10 bytes) 19:41:38.322 SERIAL [incomplete] Buffer := 0x0110000400300a590401 (10 bytes) 19:41:38.328 CNTRLR [Node 048] [+] [Association Group Information] info[2]: [object Obj [internal] ect] 19:41:38.331 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCInfoReport] payload: 0x0102000000000000 19:41:38.324 SERIAL « 0x020000000000008f (8 bytes) 19:41:38.325 SERIAL Buffer := 0x0110000400300a590401020000000000008f (18 bytes) 19:41:38.330 SERIAL » [ACK] (0x06) 19:41:38.335 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:38.342 SERIAL » 0x010b001330045905800225a68e (13 bytes) 19:41:38.336 CNTRLR « [Node 048] Received info for association group #2: info is dynamic: false profile: General: N/A 19:41:38.337 CNTRLR » [Node 048] Association group #2: Querying command list... 19:41:38.333 DRIVER ACK already received, resolving transaction 19:41:38.334 DRIVER resuming send queue 19:41:38.341 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 166 └─[AssociationGroupInfoCCCommandListGet] payload: 0x8002 19:41:38.343 DRIVER workOffSendQueue > skipping because a transaction is pending 19:41:38.348 SERIAL « [ACK] (0x06) 19:41:38.349 DRIVER ACK received from controller for current transaction 19:41:38.350 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:38.355 SERIAL « 0x0104011301e8 (6 bytes) 19:41:38.358 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:38.356 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:38.357 SERIAL » [ACK] (0x06) 19:41:38.360 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:38.396 SERIAL « 0x01070013a600000548 (9 bytes) 19:41:38.400 DRIVER « [REQ] [SendData] [confirmation] callbackId: 166 transmitStatus: OK 19:41:38.397 SERIAL Buffer := 0x01070013a600000548 (9 bytes) 19:41:38.399 SERIAL » [ACK] (0x06) 19:41:38.403 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:38.402 DRIVER ACK received from node for current transaction. RTT = 61.51 ms 19:41:38.430 SERIAL « 0x0110000400300a590401020000000000008f (18 bytes) 19:41:38.434 CNTRLR [Node 048] [~] [Association Group Information] info[2]: [object Obj [internal] ect] => [object Object] 19:41:38.431 SERIAL Buffer := 0x0110000400300a590401020000000000008f (18 bytes) 19:41:38.435 SERIAL » [ACK] (0x06) 19:41:38.436 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:38.451 SERIAL « 0x01070013a600000a47 (9 bytes) 19:41:38.456 DRIVER « [REQ] [SendData] [confirmation] callbackId: 166 transmitStatus: OK 19:41:38.452 SERIAL Buffer := 0x01070013a600000a47 (9 bytes) 19:41:38.454 SERIAL » [ACK] (0x06) 19:41:38.460 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:38.457 DRIVER ACK received from node for current transaction. RTT = 116.96 ms 19:41:38.605 SERIAL « 0x010c00040030065906020200009e (14 bytes) 19:41:38.618 CNTRLR [Node 048] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[2]: [object Map] 19:41:38.621 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[AssociationGroupInfoCCCommandListReport] payload: 0x02020000 19:41:38.606 SERIAL Buffer := 0x010c00040030065906020200009e (14 bytes) 19:41:38.619 SERIAL » [ACK] (0x06) 19:41:38.623 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:38.625 CNTRLR [Node 048] [+] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true 19:41:38.621 DRIVER ACK already received, resolving transaction 19:41:38.622 DRIVER resuming send queue 19:41:38.627 DRIVER The remaining 19 messages are for sleeping nodes, not sending anything! 19:41:38.631 DRIVER Send queue: (19 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 11, asleep] · [REQ] RequestNodeInfo [Node 15, asleep] · [REQ] RequestNodeInfo [Node 16, asleep] · [REQ] RequestNodeInfo [Node 17, asleep] · [REQ] RequestNodeInfo [Node 18, asleep] · [REQ] RequestNodeInfo [Node 20, asleep] · [REQ] RequestNodeInfo [Node 23, asleep] · [REQ] RequestNodeInfo [Node 30, asleep] · [REQ] RequestNodeInfo [Node 24, asleep] · [REQ] RequestNodeInfo [Node 31, asleep] · [REQ] RequestNodeInfo [Node 34, asleep] · [REQ] RequestNodeInfo [Node 33, asleep] · [REQ] RequestNodeInfo [Node 35, asleep] · [REQ] RequestNodeInfo [Node 37, asleep] · [REQ] RequestNodeInfo [Node 36, asleep] · [REQ] RequestNodeInfo [Node 38, asleep] · [REQ] RequestNodeInfo [Node 39, asleep] · [REQ] RequestNodeInfo [Node 41, asleep] 19:41:38.771 CNTRLR [Node 048] Interview stage completed: CommandClasses 19:41:38.778 DRIVER » [Node 048] [REQ] [GetRoutingInfo] [P: Controller] removeNonRepeaters: false removeBadLinks: false 19:41:38.780 SERIAL » 0x010700803000000048 (9 bytes) 19:41:38.772 CNTRLR [Node 048] Interview stage completed: OverwriteConfig 19:41:38.774 CNTRLR » [Node 048] requesting node neighbors... 19:41:38.785 SERIAL « [ACK] (0x06) 19:41:38.786 DRIVER ACK received from controller for current transaction 19:41:38.787 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:38.794 DRIVER « [RES] [GetRoutingInfo] [final] node ids: 1, 19, 21 19:41:38.797 CNTRLR « [Node 048] node neighbors received: 1, 19, 21 19:41:38.790 SERIAL « 0x01200180010014000000000000000000000000000000000000000000000000000 (34 bytes) 04b 19:41:38.791 SERIAL Buffer := 0x0120018001001400000000000000000000000000000000000000000 (34 bytes) 000000000004b 19:41:38.793 SERIAL » [ACK] (0x06) 19:41:38.798 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:38.795 DRIVER ACK already received, resolving transaction 19:41:38.796 DRIVER resuming send queue 19:41:38.809 DRIVER The remaining 19 messages are for sleeping nodes, not sending anything! 19:41:38.811 DRIVER Send queue: (19 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 11, asleep] · [REQ] RequestNodeInfo [Node 15, asleep] · [REQ] RequestNodeInfo [Node 16, asleep] · [REQ] RequestNodeInfo [Node 17, asleep] · [REQ] RequestNodeInfo [Node 18, asleep] · [REQ] RequestNodeInfo [Node 20, asleep] · [REQ] RequestNodeInfo [Node 23, asleep] · [REQ] RequestNodeInfo [Node 30, asleep] · [REQ] RequestNodeInfo [Node 24, asleep] · [REQ] RequestNodeInfo [Node 31, asleep] · [REQ] RequestNodeInfo [Node 34, asleep] · [REQ] RequestNodeInfo [Node 33, asleep] · [REQ] RequestNodeInfo [Node 35, asleep] · [REQ] RequestNodeInfo [Node 37, asleep] · [REQ] RequestNodeInfo [Node 36, asleep] · [REQ] RequestNodeInfo [Node 38, asleep] · [REQ] RequestNodeInfo [Node 39, asleep] · [REQ] RequestNodeInfo [Node 41, asleep] 19:41:38.799 CNTRLR [Node 048] Interview stage completed: Neighbors 19:41:38.800 CNTRLR [Node 048] Interview completed 19:41:38.800 CNTRLR [Node 048] The node is ready to be used 19:41:38.805 CNTRLR [Node 048] node is ready 19:41:51.582 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 167 └─[SupervisionCCGet] │ payload: 0x010426042000 └─[MultilevelSwitchCCStartLevelChange] payload: 0x2000 19:41:51.584 SERIAL » 0x010f001330086c0101042604200025a733 (17 bytes) 19:41:51.589 SERIAL « [ACK] (0x06) 19:41:51.590 DRIVER ACK received from controller for current transaction 19:41:51.591 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:51.595 SERIAL « 0x0104011301e8 (6 bytes) 19:41:51.599 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:51.597 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:51.598 SERIAL » [ACK] (0x06) 19:41:51.601 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:51.611 SERIAL « 0x01070013a70000024e (9 bytes) 19:41:51.615 DRIVER « [REQ] [SendData] [confirmation] callbackId: 167 transmitStatus: OK 19:41:51.612 SERIAL Buffer := 0x01070013a70000024e (9 bytes) 19:41:51.613 SERIAL » [ACK] (0x06) 19:41:51.617 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:51.616 DRIVER ACK received from node for current transaction. RTT = 38.30 ms 19:41:51.675 SERIAL « 0x010b00040030056c0201ff0055 (13 bytes) 19:41:51.684 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[SupervisionCCReport] payload: 0x01ff00 19:41:51.677 SERIAL Buffer := 0x010b00040030056c0201ff0055 (13 bytes) 19:41:51.682 SERIAL » [ACK] (0x06) 19:41:51.687 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:51.686 DRIVER ACK already received, resolving transaction 19:41:51.686 DRIVER resuming send queue 19:41:51.690 DRIVER The remaining 19 messages are for sleeping nodes, not sending anything! 19:41:51.691 DRIVER Send queue: (19 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 11, asleep] · [REQ] RequestNodeInfo [Node 15, asleep] · [REQ] RequestNodeInfo [Node 16, asleep] · [REQ] RequestNodeInfo [Node 17, asleep] · [REQ] RequestNodeInfo [Node 18, asleep] · [REQ] RequestNodeInfo [Node 20, asleep] · [REQ] RequestNodeInfo [Node 23, asleep] · [REQ] RequestNodeInfo [Node 30, asleep] · [REQ] RequestNodeInfo [Node 24, asleep] · [REQ] RequestNodeInfo [Node 31, asleep] · [REQ] RequestNodeInfo [Node 34, asleep] · [REQ] RequestNodeInfo [Node 33, asleep] · [REQ] RequestNodeInfo [Node 35, asleep] · [REQ] RequestNodeInfo [Node 37, asleep] · [REQ] RequestNodeInfo [Node 36, asleep] · [REQ] RequestNodeInfo [Node 38, asleep] · [REQ] RequestNodeInfo [Node 39, asleep] · [REQ] RequestNodeInfo [Node 41, asleep] 19:41:55.721 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 168 └─[SupervisionCCGet] │ payload: 0x02022605 └─[MultilevelSwitchCCStopLevelChange] 19:41:55.722 SERIAL » 0x010d001330066c010202260525a814 (15 bytes) 19:41:55.727 SERIAL « [ACK] (0x06) 19:41:55.728 DRIVER ACK received from controller for current transaction 19:41:55.729 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:55.733 SERIAL « 0x0104011301e8 (6 bytes) 19:41:55.736 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:55.734 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:55.735 SERIAL » [ACK] (0x06) 19:41:55.737 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:55.843 SERIAL « 0x01070013a800000b48 (9 bytes) 19:41:55.846 DRIVER « [REQ] [SendData] [confirmation] callbackId: 168 transmitStatus: OK 19:41:55.844 SERIAL Buffer := 0x01070013a800000b48 (9 bytes) 19:41:55.845 SERIAL » [ACK] (0x06) 19:41:55.848 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:55.847 DRIVER ACK received from node for current transaction. RTT = 127.38 ms 19:41:55.918 SERIAL « 0x010b00040030052603000000e0 (13 bytes) 19:41:55.923 CNTRLR [Node 048] [~] [Multilevel Switch] targetValue: 0 => 0 [Endpoint 0] 19:41:55.919 SERIAL Buffer := 0x010b00040030052603000000e0 (13 bytes) 19:41:55.934 SERIAL » [ACK] (0x06) 19:41:55.936 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:55.927 CNTRLR [Node 048] [~] [Multilevel Switch] duration: [Duration: 0seconds] [Endpoint 0] => [Duration: 0seconds] 19:41:55.931 CNTRLR [Node 048] [~] [Multilevel Switch] currentValue: 0 => 0 [Endpoint 0] 19:41:55.942 SERIAL « 0x010b00040030056c0202ff0056 (13 bytes) 19:41:55.950 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[SupervisionCCReport] payload: 0x02ff00 19:41:55.944 SERIAL Buffer := 0x010b00040030056c0202ff0056 (13 bytes) 19:41:55.946 SERIAL » [ACK] (0x06) 19:41:55.954 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:55.951 DRIVER ACK already received, resolving transaction 19:41:55.952 DRIVER resuming send queue 19:41:55.956 DRIVER The remaining 19 messages are for sleeping nodes, not sending anything! 19:41:55.958 DRIVER Send queue: (19 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 11, asleep] · [REQ] RequestNodeInfo [Node 15, asleep] · [REQ] RequestNodeInfo [Node 16, asleep] · [REQ] RequestNodeInfo [Node 17, asleep] · [REQ] RequestNodeInfo [Node 18, asleep] · [REQ] RequestNodeInfo [Node 20, asleep] · [REQ] RequestNodeInfo [Node 23, asleep] · [REQ] RequestNodeInfo [Node 30, asleep] · [REQ] RequestNodeInfo [Node 24, asleep] · [REQ] RequestNodeInfo [Node 31, asleep] · [REQ] RequestNodeInfo [Node 34, asleep] · [REQ] RequestNodeInfo [Node 33, asleep] · [REQ] RequestNodeInfo [Node 35, asleep] · [REQ] RequestNodeInfo [Node 37, asleep] · [REQ] RequestNodeInfo [Node 36, asleep] · [REQ] RequestNodeInfo [Node 38, asleep] · [REQ] RequestNodeInfo [Node 39, asleep] · [REQ] RequestNodeInfo [Node 41, asleep] 19:41:58.425 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 169 └─[SupervisionCCGet] │ payload: 0x030426046000 └─[MultilevelSwitchCCStartLevelChange] payload: 0x6000 19:41:58.426 SERIAL » 0x010f001330086c0103042604600025a97f (17 bytes) 19:41:58.432 SERIAL « [ACK] (0x06) 19:41:58.433 DRIVER ACK received from controller for current transaction 19:41:58.434 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:58.438 SERIAL « 0x0104011301e8 (6 bytes) 19:41:58.441 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:41:58.439 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:41:58.440 SERIAL » [ACK] (0x06) 19:41:58.443 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:58.491 SERIAL « 0x01070013a900000644 (9 bytes) 19:41:58.494 DRIVER « [REQ] [SendData] [confirmation] callbackId: 169 transmitStatus: OK 19:41:58.492 SERIAL Buffer := 0x01070013a900000644 (9 bytes) 19:41:58.493 SERIAL » [ACK] (0x06) 19:41:58.496 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:58.495 DRIVER ACK received from node for current transaction. RTT = 71.83 ms 19:41:58.601 SERIAL « 0x010b00040030056c0203ff0057 (13 bytes) 19:41:58.609 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[SupervisionCCReport] payload: 0x03ff00 19:41:58.602 SERIAL Buffer := 0x010b00040030056c0203ff0057 (13 bytes) 19:41:58.605 SERIAL » [ACK] (0x06) 19:41:58.615 SERIAL The receive buffer is empty, waiting for the next chunk... 19:41:58.611 DRIVER ACK already received, resolving transaction 19:41:58.613 DRIVER resuming send queue 19:41:58.620 DRIVER The remaining 19 messages are for sleeping nodes, not sending anything! 19:41:58.621 DRIVER Send queue: (19 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 11, asleep] · [REQ] RequestNodeInfo [Node 15, asleep] · [REQ] RequestNodeInfo [Node 16, asleep] · [REQ] RequestNodeInfo [Node 17, asleep] · [REQ] RequestNodeInfo [Node 18, asleep] · [REQ] RequestNodeInfo [Node 20, asleep] · [REQ] RequestNodeInfo [Node 23, asleep] · [REQ] RequestNodeInfo [Node 30, asleep] · [REQ] RequestNodeInfo [Node 24, asleep] · [REQ] RequestNodeInfo [Node 31, asleep] · [REQ] RequestNodeInfo [Node 34, asleep] · [REQ] RequestNodeInfo [Node 33, asleep] · [REQ] RequestNodeInfo [Node 35, asleep] · [REQ] RequestNodeInfo [Node 37, asleep] · [REQ] RequestNodeInfo [Node 36, asleep] · [REQ] RequestNodeInfo [Node 38, asleep] · [REQ] RequestNodeInfo [Node 39, asleep] · [REQ] RequestNodeInfo [Node 41, asleep] 19:42:02.631 DRIVER » [Node 048] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 170 └─[SupervisionCCGet] │ payload: 0x04022605 └─[MultilevelSwitchCCStopLevelChange] 19:42:02.633 SERIAL » 0x010d001330066c010402260525aa10 (15 bytes) 19:42:02.639 DRIVER ACK received from controller for current transaction 19:42:02.646 DRIVER « [RES] [SendData] [confirmation] wasSent: true 19:42:02.745 DRIVER « [Node 048] [REQ] [ApplicationCommand] [final] └─[SupervisionCCReport] payload: 0x04ff00 19:42:02.746 DRIVER ACK already received, resolving transaction 19:42:02.746 DRIVER resuming send queue 19:42:02.750 DRIVER The remaining 19 messages are for sleeping nodes, not sending anything! 19:42:02.751 DRIVER Send queue: (19 messages) · [REQ] RequestNodeInfo [Node 3, asleep] · [REQ] RequestNodeInfo [Node 11, asleep] · [REQ] RequestNodeInfo [Node 15, asleep] · [REQ] RequestNodeInfo [Node 16, asleep] · [REQ] RequestNodeInfo [Node 17, asleep] · [REQ] RequestNodeInfo [Node 18, asleep] · [REQ] RequestNodeInfo [Node 20, asleep] · [REQ] RequestNodeInfo [Node 23, asleep] · [REQ] RequestNodeInfo [Node 30, asleep] · [REQ] RequestNodeInfo [Node 24, asleep] · [REQ] RequestNodeInfo [Node 31, asleep] · [REQ] RequestNodeInfo [Node 34, asleep] · [REQ] RequestNodeInfo [Node 33, asleep] · [REQ] RequestNodeInfo [Node 35, asleep] · [REQ] RequestNodeInfo [Node 37, asleep] · [REQ] RequestNodeInfo [Node 36, asleep] · [REQ] RequestNodeInfo [Node 38, asleep] · [REQ] RequestNodeInfo [Node 39, asleep] · [REQ] RequestNodeInfo [Node 41, asleep] 19:42:02.801 DRIVER handling request SendData (19) 19:42:02.801 DRIVER no handlers registered! 19:42:02.638 SERIAL « [ACK] (0x06) 19:42:02.640 SERIAL The receive buffer is empty, waiting for the next chunk... 19:42:02.644 SERIAL « 0x0104011301e8 (6 bytes) 19:42:02.645 SERIAL Buffer := 0x0104011301e8 (6 bytes) 19:42:02.645 SERIAL » [ACK] (0x06) 19:42:02.647 SERIAL The receive buffer is empty, waiting for the next chunk... 19:42:02.742 SERIAL « 0x010b00040030056c0204ff0050 (13 bytes) 19:42:02.743 SERIAL Buffer := 0x010b00040030056c0204ff0050 (13 bytes) 19:42:02.744 SERIAL » [ACK] (0x06) 19:42:02.747 SERIAL The receive buffer is empty, waiting for the next chunk... 19:42:02.798 SERIAL « 0x01070013aa00001051 (9 bytes) 19:42:02.799 SERIAL Buffer := 0x01070013aa00001051 (9 bytes) 19:42:02.800 SERIAL » [ACK] (0x06) 19:42:02.802 SERIAL The receive buffer is empty, waiting for the next chunk... 19:42:07.305 DRIVER destroying driver instance...