17:00:52.217 CNTRLR [Node 007] [~] [Thermostat Setpoint] setpoint[1]: 12 => 28 [Endpoint 0] 17:00:52.229 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] payload: 0x01220118 17:01:06.010 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 244 └─[SupervisionCCGet] │ session id: 28 │ request updates: true └─[MultilevelSwitchCCSet] target value: 0 17:01:06.016 DRIVER ACK received from controller for current transaction 17:01:06.024 DRIVER « [RES] [SendData] [confirmation] wasSent: true 17:01:07.872 DRIVER « [REQ] [SendData] [confirmation] callbackId: 244 transmitStatus: OK 17:01:07.873 DRIVER ACK received from node for current transaction. RTT = 1863.84 ms 17:01:07.953 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[SupervisionCCReport] session id: 28 more updates follow: false status: Success duration: [Duration: 0seconds] 17:01:07.954 DRIVER ACK already received, resolving transaction 17:01:07.955 DRIVER resuming send queue 17:01:07.957 DRIVER » [Node 007] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 245 └─[MultilevelSwitchCCGet] 17:01:07.958 DRIVER workOffSendQueue > skipping because a transaction is pending 17:01:07.963 DRIVER ACK received from controller for current transaction 17:01:07.970 DRIVER « [RES] [SendData] [confirmation] wasSent: true 17:01:08.076 DRIVER « [REQ] [SendData] [confirmation] callbackId: 245 transmitStatus: OK 17:01:08.076 DRIVER ACK received from node for current transaction. RTT = 119.76 ms 17:01:09.197 CNTRLR [Node 007] The node did not respond to the current transaction, scheduling att empt (2/3) in 500 ms... 17:01:09.697 DRIVER » [Node 007] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 245 └─[MultilevelSwitchCCGet] 17:01:09.703 DRIVER ACK received from controller for current transaction 17:01:09.711 DRIVER « [RES] [SendData] [confirmation] wasSent: true 17:01:09.772 DRIVER « [REQ] [SendData] [confirmation] callbackId: 245 transmitStatus: OK 17:01:09.773 DRIVER ACK received from node for current transaction. RTT = 76.07 ms 17:01:09.852 CNTRLR [Node 007] [~] [Multilevel Switch] currentValue: 0 => 31 [Endpoint 0] 17:01:09.862 DRIVER « [Node 007] [REQ] [ApplicationCommand] [final] └─[MultilevelSwitchCCReport] current value: 31 17:01:09.863 DRIVER ACK already received, resolving transaction 17:01:09.863 DRIVER resuming send queue 17:01:09.866 DRIVER The remaining 2 messages are for sleeping nodes, not sending anything! 17:01:09.866 DRIVER Send queue: (2 messages) · [REQ] SendData (BinarySensorCCGet) [Node 4, asleep] · [REQ] SendData (NoOperationCC) [Node 6, asleep] 17:01:11.138 CNTRLR [Node 006] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 17:01:11.147 CNTRLR [Node 006] [~] [Multilevel Sensor] Air temperature: 64 => 64 [Endpoint 0] 17:01:11.156 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MultiCommandCCCommandEncapsulation] payload: 0x0106310501220280 17:01:11.157 CNTRLR « [Node 006] TODO: no handler for application command 17:01:11.218 CNTRLR [Node 006] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 17:01:11.223 CNTRLR [Node 006] [~] [Multilevel Sensor] Air temperature: 64 => 64 [Endpoint 0] 17:01:11.228 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MultiCommandCCCommandEncapsulation] payload: 0x0106310501220280 17:01:11.229 CNTRLR « [Node 006] TODO: no handler for application command