13:24:39.092 DRIVER ███████╗ ██╗ ██╗ █████╗ ██╗ ██╗ ███████╗ ██╗ ███████╗ ╚══███╔╝ ██║ ██║ ██╔══██╗ ██║ ██║ ██╔════╝ ██║ ██╔════╝ ███╔╝ ██║ █╗ ██║ ███████║ ██║ ██║ █████╗ █████╗ ██║ ███████╗ ███╔╝ ██║███╗██║ ██╔══██║ ╚██╗ ██╔╝ ██╔══╝ ╚════╝ ██ ██║ ╚════██║ ███████╗ ╚███╔███╔╝ ██║ ██║ ╚████╔╝ ███████╗ ╚█████╔╝ ███████║ ╚══════╝ ╚══╝╚══╝ ╚═╝ ╚═╝ ╚═══╝ ╚══════╝ ╚════╝ ╚══════╝ 13:24:39.101 DRIVER version 4.0.7 13:24:39.103 DRIVER 13:24:39.104 DRIVER starting driver... 13:24:39.104 DRIVER opening serial port /dev/ttyACM0 13:24:39.518 DRIVER serial port opened 13:24:39.527 SERIAL » [NAK] (0x15) 13:24:41.031 DRIVER loading configuration... 13:24:42.215 DRIVER beginning interview... 13:24:42.219 DRIVER added request handler for AddNodeToNetwork (0x4a)... 1 registered 13:24:42.220 DRIVER added request handler for RemoveNodeFromNetwork (0x4b)... 1 registered 13:24:42.226 CNTRLR beginning interview... 13:24:42.226 CNTRLR querying version info... 13:24:42.239 DRIVER » [REQ] [GetControllerVersion] [P: Controller] 13:24:42.241 SERIAL » 0x01030015e9 (5 bytes) 13:24:42.248 SERIAL « [ACK] (0x06) 13:24:42.250 DRIVER ACK received from controller for current transaction 13:24:42.251 SERIAL « 0x011001155a2d5761766520332e3935000199 (18 bytes) 13:24:42.254 SERIAL » [ACK] (0x06) 13:24:42.257 DRIVER « [RES] [GetControllerVersion] [final] payload: 0x5a2d5761766520332e39350001 13:24:42.258 DRIVER ACK already received, resolving transaction 13:24:42.259 DRIVER resuming send queue 13:24:42.261 CNTRLR received version info: controller type: Static Controller library version: Z-Wave 3.95 13:24:42.261 CNTRLR querying controller IDs... 13:24:42.265 DRIVER » [REQ] [GetControllerId] [P: Controller] 13:24:42.266 SERIAL » 0x01030020dc (5 bytes) 13:24:42.267 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:42.271 SERIAL « [ACK] (0x06) 13:24:42.272 DRIVER ACK received from controller for current transaction 13:24:42.274 SERIAL « 0x01080120dc3452b301de (10 bytes) 13:24:42.276 SERIAL » [ACK] (0x06) 13:24:42.276 DRIVER « [RES] [GetControllerId] [final] payload: 0xdc3452b301 13:24:42.277 DRIVER ACK already received, resolving transaction 13:24:42.278 DRIVER resuming send queue 13:24:42.279 CNTRLR received controller IDs: home ID: 0xdc3452b3 own node ID: 1 13:24:42.279 CNTRLR querying controller capabilities... 13:24:42.282 DRIVER » [REQ] [GetControllerCapabilities] [P: Controller] 13:24:42.283 SERIAL » 0x01030005f9 (5 bytes) 13:24:42.283 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:42.286 SERIAL « [ACK] (0x06) 13:24:42.287 DRIVER ACK received from controller for current transaction 13:24:42.288 SERIAL « 0x0104010508f7 (6 bytes) 13:24:42.289 SERIAL » [ACK] (0x06) 13:24:42.290 DRIVER « [RES] [GetControllerCapabilities] [final] payload: 0x08 13:24:42.290 DRIVER ACK already received, resolving transaction 13:24:42.291 DRIVER resuming send queue 13:24:42.292 CNTRLR received controller capabilities: controller role: primary is in other network: false is SIS present: false was real primary: true is a SUC: false 13:24:42.293 CNTRLR querying API capabilities... 13:24:42.296 DRIVER » [REQ] [GetSerialApiCapabilities] [P: Controller] 13:24:42.297 SERIAL » 0x01030007fb (5 bytes) 13:24:42.297 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:42.300 SERIAL « [ACK] (0x06) 13:24:42.301 DRIVER ACK received from controller for current transaction 13:24:42.303 SERIAL « 0x012b0107010000860001005afe81ff884f1f0000fb9f7da067000080008086000 (45 bytes) 000e87300000e0000600000fb 13:24:42.306 SERIAL » [ACK] (0x06) 13:24:42.307 DRIVER « [RES] [GetSerialApiCapabilities] [final] payload: 0x010000860001005afe81ff884f1f0000fb9f7da067000080008086000000e8730 0000e0000600000 13:24:42.308 DRIVER ACK already received, resolving transaction 13:24:42.308 DRIVER resuming send queue 13:24:42.310 CNTRLR received API capabilities: serial API version: 1.0 manufacturer ID: 0x86 product type: 0x01 product ID: 0x5a supported functions: · GetSerialApiInitData (0x02) · FUNC_ID_SERIAL_API_APPL_NODE_INFORMATION (0x03) · ApplicationCommand (0x04) · GetControllerCapabilities (0x05) · SetSerialApiTimeouts (0x06) · GetSerialApiCapabilities (0x07) · FUNC_ID_SERIAL_API_SOFT_RESET (0x08) · UNKNOWN_FUNC_UNKNOWN_0x09 (0x09) · UNKNOWN_FUNC_RF_RECEIVE_MODE (0x10) · UNKNOWN_FUNC_SET_SLEEP_MODE (0x11) · FUNC_ID_ZW_SEND_NODE_INFORMATION (0x12) · SendData (0x13) · SendDataMulticast (0x14) · GetControllerVersion (0x15) · SendDataAbort (0x16) · FUNC_ID_ZW_R_F_POWER_LEVEL_SET (0x17) · UNKNOWN_FUNC_SEND_DATA_META (0x18) · FUNC_ID_ZW_GET_RANDOM (0x1c) · GetControllerId (0x20) · UNKNOWN_FUNC_MEMORY_GET_BYTE (0x21) · UNKNOWN_FUNC_MEMORY_PUT_BYTE (0x22) · UNKNOWN_FUNC_MEMORY_GET_BUFFER (0x23) · UNKNOWN_FUNC_MEMORY_PUT_BUFFER (0x24) · UNKNOWN_FUNC_FlashAutoProgSet (0x27) · UNKNOWN_FUNC_NVMGetId (0x29) · UNKNOWN_FUNC_NVMExtReadLongBuffer (0x2a) · UNKNOWN_FUNC_NVMExtWriteLongBuffer (0x2b) · UNKNOWN_FUNC_NVMExtReadLongByte (0x2c) · UNKNOWN_FUNC_NVMExtWriteLongByte (0x2d) · GetNodeProtocolInfo (0x41) · HardReset (0x42) · FUNC_ID_ZW_REPLICATION_COMMAND_COMPLETE (0x44) · FUNC_ID_ZW_REPLICATION_SEND_DATA (0x45) · AssignReturnRoute (0x46) · DeleteReturnRoute (0x47) · RequestNodeNeighborUpdate (0x48) · ApplicationUpdateRequest (0x49) · AddNodeToNetwork (0x4a) · RemoveNodeFromNetwork (0x4b) · FUNC_ID_ZW_CREATE_NEW_PRIMARY (0x4c) · FUNC_ID_ZW_CONTROLLER_CHANGE (0x4d) · FUNC_ID_ZW_SET_LEARN_MODE (0x50) · FUNC_ID_ZW_ASSIGN_SUC_RETURN_ROUTE (0x51) · FUNC_ID_ZW_REQUEST_NETWORK_UPDATE (0x53) · FUNC_ID_ZW_SET_SUC_NODE_ID (0x54) · FUNC_ID_ZW_DELETE_SUC_RETURN_ROUTE (0x55) · GetSUCNodeId (0x56) · UNKNOWN_FUNC_SEND_SUC_ID (0x57) · FUNC_ID_ZW_EXPLORE_REQUEST_INCLUSION (0x5e) · RequestNodeInfo (0x60) · RemoveFailedNode (0x61) · IsFailedNode (0x62) · FUNC_ID_ZW_REPLACE_FAILED_NODE (0x63) · UNKNOWN_FUNC_UNKNOWN_0x66 (0x66) · UNKNOWN_FUNC_UNKNOWN_0x67 (0x67) · GetRoutingInfo (0x80) · UNKNOWN_FUNC_LOCK_ROUTE_RESPONSE (0x90) · UNKNOWN_FUNC_GET_PRIORITY_ROUTE (0x92) · UNKNOWN_FUNC_SET_PRIORITY_ROUTE (0x93) · UNKNOWN_FUNC_UNKNOWN_0x98 (0x98) · UNKNOWN_FUNC_UNKNOWN_0xB4 (0xb4) · UNKNOWN_FUNC_WATCH_DOG_ENABLE (0xb6) · UNKNOWN_FUNC_WATCH_DOG_DISABLE (0xb7) · UNKNOWN_FUNC_WATCH_DOG_KICK (0xb8) · UNKNOWN_FUNC_UNKNOWN_0xB9 (0xb9) · UNKNOWN_FUNC_RF_POWERLEVEL_GET (0xba) · UNKNOWN_FUNC_GET_LIBRARY_TYPE (0xbd) · UNKNOWN_FUNC_SEND_TEST_FRAME (0xbe) · UNKNOWN_FUNC_GET_PROTOCOL_STATUS (0xbf) · UNKNOWN_FUNC_UNKNOWN_0xD2 (0xd2) · UNKNOWN_FUNC_UNKNOWN_0xD3 (0xd3) · UNKNOWN_FUNC_UNKNOWN_0xD4 (0xd4) · undefined (0xee) · UNKNOWN_FUNC_UNKNOWN_0xEF (0xef) 13:24:42.312 CNTRLR finding SUC... 13:24:42.315 DRIVER » [REQ] [GetSUCNodeId] [P: Controller] 13:24:42.316 SERIAL » 0x01030056aa (5 bytes) 13:24:42.317 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:42.320 SERIAL « [ACK] (0x06) 13:24:42.321 DRIVER ACK received from controller for current transaction 13:24:42.322 SERIAL « 0x0104015600ac (6 bytes) 13:24:42.323 SERIAL » [ACK] (0x06) 13:24:42.324 DRIVER « [RES] [GetSUCNodeId] [final] payload: 0x00 13:24:42.325 DRIVER ACK already received, resolving transaction 13:24:42.325 DRIVER resuming send queue 13:24:42.326 CNTRLR no SUC present 13:24:42.333 DRIVER The send queue is empty 13:24:42.587 CNTRLR querying node information... 13:24:42.590 DRIVER » [REQ] [GetSerialApiInitData] [P: Controller] 13:24:42.591 SERIAL » 0x01030002fe (5 bytes) 13:24:42.595 SERIAL « [ACK] (0x06) 13:24:42.596 DRIVER ACK received from controller for current transaction 13:24:42.689 SERIAL « 0x0125010205001dff1f00000000000000000000000000000000000000000000000 (39 bytes) 0000000050024 13:24:42.692 SERIAL » [ACK] (0x06) 13:24:42.694 DRIVER « [RES] [GetSerialApiInitData] [final] payload: 0x05001dff1f0000000000000000000000000000000000000000000000000000000 500 13:24:42.695 DRIVER ACK already received, resolving transaction 13:24:42.695 DRIVER resuming send queue 13:24:42.697 CNTRLR received node information: controller role: primary controller is a SUC: false controller is a slave: false controller supports timers: false nodes in the network: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 13:24:42.705 DRIVER The send queue is empty 13:24:42.707 DRIVER Cache file for homeId 0xdc3452b3 found, attempting to restore the network from cache... 13:24:42.726 CNTRLR [Node 001] trying to load device config 13:24:42.754 CNTRLR [Node 001] device config loaded 13:24:42.757 CNTRLR [Node 002] trying to load device config 13:24:42.785 CNTRLR [Node 002] device config loaded 13:24:42.787 CNTRLR [Node 003] trying to load device config 13:24:42.807 CNTRLR [Node 003] device config loaded 13:24:42.809 CNTRLR [Node 004] trying to load device config 13:24:42.829 CNTRLR [Node 004] device config loaded 13:24:42.831 CNTRLR [Node 005] trying to load device config 13:24:42.853 CNTRLR [Node 005] device config loaded 13:24:42.855 CNTRLR [Node 006] trying to load device config 13:24:42.873 CNTRLR [Node 006] device config loaded 13:24:42.875 CNTRLR [Node 010] trying to load device config 13:24:42.903 CNTRLR [Node 010] device config loaded 13:24:42.905 CNTRLR [Node 011] trying to load device config 13:24:42.945 CNTRLR [Node 011] device config loaded 13:24:42.947 CNTRLR [Node 012] trying to load device config 13:24:42.971 CNTRLR [Node 012] device config loaded 13:24:42.973 CNTRLR [Node 013] trying to load device config 13:24:42.995 CNTRLR [Node 013] device config loaded 13:24:42.997 DRIVER Restoring the network from cache was successful! 13:24:43.010 CNTRLR [Node 001] [Manufacturer Specific] manufacturerId: metadata updated 13:24:43.027 CNTRLR [Node 001] [Manufacturer Specific] productType: metadata updated 13:24:43.039 CNTRLR [Node 001] [Manufacturer Specific] productId: metadata updated 13:24:43.054 CNTRLR [Node 001] [~] [Manufacturer Specific] manufacturerId: 134 => 134 13:24:43.062 CNTRLR [Node 001] [~] [Manufacturer Specific] productType: 1 => 1 13:24:43.069 CNTRLR [Node 001] [~] [Manufacturer Specific] productId: 90 => 90 13:24:43.076 CNTRLR setting serial API timeouts: ack = 1000 ms, byte = 150 ms 13:24:43.079 DRIVER » [REQ] [SetSerialApiTimeouts] [P: Controller] 13:24:43.080 SERIAL » 0x01050006640f97 (7 bytes) 13:24:43.083 SERIAL « [ACK] (0x06) 13:24:43.084 DRIVER ACK received from controller for current transaction 13:24:43.084 SERIAL « 0x01050106960f64 (7 bytes) 13:24:43.086 SERIAL » [ACK] (0x06) 13:24:43.086 DRIVER « [RES] [SetSerialApiTimeouts] [final] payload: 0x960f 13:24:43.087 DRIVER ACK already received, resolving transaction 13:24:43.087 DRIVER resuming send queue 13:24:43.088 CNTRLR serial API timeouts overwritten. The old values were: ack = 1500 ms, byte = 15 0 ms 13:24:43.088 CNTRLR Interview completed 13:24:43.092 DRIVER driver ready 13:24:43.104 CNTRLR [Node 001] Beginning interview - last completed stage: RestartFromCache 13:24:43.106 CNTRLR [Node 001] not pinging the controller 13:24:43.114 DRIVER The send queue is empty 13:24:43.144 CNTRLR [Node 001] Interview stage completed: CommandClasses 13:24:43.146 CNTRLR [Node 001] trying to load device config 13:24:43.156 CNTRLR [Node 001] device config loaded 13:24:43.157 CNTRLR [Node 001] Interview stage completed: OverwriteConfig 13:24:43.164 CNTRLR » [Node 001] requesting node neighbors... 13:24:43.169 DRIVER » [Node 001] [REQ] [GetRoutingInfo] [P: Controller] removeNonRepeaters: false removeBadLinks: false 13:24:43.171 SERIAL » 0x010700800100000079 (9 bytes) 13:24:43.174 SERIAL « [ACK] (0x06) 13:24:43.179 DRIVER ACK received from controller for current transaction 13:24:43.181 SERIAL « 0x01200180fe1700000000000000000000000000000000000000000000000000000 (34 bytes) 0b7 13:24:43.184 SERIAL » [ACK] (0x06) 13:24:43.186 DRIVER « [RES] [GetRoutingInfo] [final] node ids: 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 13 13:24:43.187 DRIVER ACK already received, resolving transaction 13:24:43.189 DRIVER resuming send queue 13:24:43.190 CNTRLR « [Node 001] node neighbors received: 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 13 13:24:43.192 CNTRLR [Node 001] Interview stage completed: Neighbors 13:24:43.193 CNTRLR [Node 001] Interview completed 13:24:43.194 CNTRLR [Node 001] The node is ready to be used 13:24:43.199 CNTRLR [Node 002] Beginning interview - last completed stage: RestartFromCache 13:24:43.200 CNTRLR » [Node 002] pinging the node... 13:24:43.206 CNTRLR [Node 003] Beginning interview - last completed stage: RestartFromCache 13:24:43.207 CNTRLR » [Node 003] pinging the node... 13:24:43.209 CNTRLR [Node 004] Beginning interview - last completed stage: RestartFromCache 13:24:43.209 CNTRLR » [Node 004] pinging the node... 13:24:43.210 CNTRLR [Node 005] Beginning interview - last completed stage: RestartFromCache 13:24:43.211 CNTRLR » [Node 005] pinging the node... 13:24:43.211 CNTRLR [Node 006] Beginning interview - last completed stage: RestartFromCache 13:24:43.212 CNTRLR » [Node 006] pinging the node... 13:24:43.213 CNTRLR [Node 007] Beginning interview - last completed stage: ProtocolInfo 13:24:43.213 CNTRLR » [Node 007] pinging the node... 13:24:43.215 CNTRLR [Node 008] Beginning interview - last completed stage: ProtocolInfo 13:24:43.215 CNTRLR » [Node 008] pinging the node... 13:24:43.216 CNTRLR [Node 009] Beginning interview - last completed stage: ProtocolInfo 13:24:43.217 CNTRLR » [Node 009] pinging the node... 13:24:43.218 CNTRLR [Node 010] Beginning interview - last completed stage: RestartFromCache 13:24:43.218 CNTRLR » [Node 010] pinging the node... 13:24:43.219 CNTRLR [Node 011] Beginning interview - last completed stage: RestartFromCache 13:24:43.219 CNTRLR » [Node 011] pinging the node... 13:24:43.220 CNTRLR [Node 012] Beginning interview - last completed stage: RestartFromCache 13:24:43.220 CNTRLR » [Node 012] pinging the node... 13:24:43.221 CNTRLR [Node 013] Beginning interview - last completed stage: RestartFromCache 13:24:43.221 CNTRLR » [Node 013] pinging the node... 13:24:43.226 DRIVER » [Node 002] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 1 └─[NoOperationCC] 13:24:43.228 SERIAL » 0x010800130201002501c3 (10 bytes) 13:24:43.229 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:43.229 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:43.229 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:43.230 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:43.230 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:43.230 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:43.231 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:43.231 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:43.231 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:43.231 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:43.232 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:43.232 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:43.238 SERIAL « [ACK] (0x06) 13:24:43.239 DRIVER ACK received from controller for current transaction 13:24:43.242 SERIAL « 0x0104011301e8 (6 bytes) 13:24:43.243 SERIAL » [ACK] (0x06) 13:24:43.246 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:44.506 SERIAL « 0x010700130100007f95 (9 bytes) 13:24:44.507 SERIAL » [ACK] (0x06) 13:24:44.509 DRIVER « [REQ] [SendData] [final] callbackId: 1 transmitStatus: OK 13:24:44.510 DRIVER ACK already received, resolving transaction 13:24:44.510 DRIVER resuming send queue 13:24:44.511 CNTRLR « [Node 002] ping successful 13:24:44.525 CNTRLR [Node 002] ManufacturerSpecificCC: doing a partial interview... 13:24:44.527 CNTRLR [Node 002] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 13:24:44.529 DRIVER » [Node 003] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 2 └─[NoOperationCC] 13:24:44.530 SERIAL » 0x010800130301002502c1 (10 bytes) 13:24:44.544 SERIAL « [ACK] (0x06) 13:24:44.545 DRIVER ACK received from controller for current transaction 13:24:44.545 SERIAL « 0x0104011301e8 (6 bytes) 13:24:44.546 SERIAL » [ACK] (0x06) 13:24:44.547 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:44.553 CNTRLR [Node 002] VersionCC: doing a partial interview... 13:24:44.554 CNTRLR [Node 002] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 13:24:44.555 CNTRLR [Node 002] trying to load device config 13:24:44.570 CNTRLR [Node 002] device config loaded 13:24:44.572 CNTRLR [Node 002] ZWavePlusCC: doing a partial interview... 13:24:44.573 CNTRLR [Node 002] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 13:24:44.576 CNTRLR [Node 002] BatteryCC: doing a partial interview... 13:24:44.577 CNTRLR » [Node 002] querying battery status... 13:24:44.580 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:45.819 SERIAL « 0x010700130200008168 (9 bytes) 13:24:45.820 SERIAL » [ACK] (0x06) 13:24:45.821 DRIVER « [REQ] [SendData] [final] callbackId: 2 transmitStatus: OK 13:24:45.821 DRIVER ACK already received, resolving transaction 13:24:45.822 DRIVER resuming send queue 13:24:45.822 CNTRLR « [Node 003] ping successful 13:24:45.827 CNTRLR [Node 003] ManufacturerSpecificCC: doing a partial interview... 13:24:45.829 CNTRLR [Node 003] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 13:24:45.831 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 3 └─[BatteryCCGet] 13:24:45.832 SERIAL » 0x0109001302028002250341 (11 bytes) 13:24:45.846 SERIAL « [ACK] (0x06) 13:24:45.847 DRIVER ACK received from controller for current transaction 13:24:45.848 SERIAL « 0x0104011301e8 (6 bytes) 13:24:45.848 SERIAL » [ACK] (0x06) 13:24:45.853 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:45.856 CNTRLR [Node 003] VersionCC: doing a partial interview... 13:24:45.857 CNTRLR [Node 003] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 13:24:45.858 CNTRLR [Node 003] trying to load device config 13:24:45.873 CNTRLR [Node 003] device config loaded 13:24:45.875 CNTRLR [Node 003] ZWavePlusCC: doing a partial interview... 13:24:45.875 CNTRLR [Node 003] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 13:24:45.876 CNTRLR [Node 003] BatteryCC: doing a partial interview... 13:24:45.877 CNTRLR » [Node 003] querying battery status... 13:24:45.878 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:45.879 SERIAL « 0x0107001303000002ea (9 bytes) 13:24:45.880 SERIAL » [ACK] (0x06) 13:24:45.881 DRIVER « [REQ] [SendData] [confirmation] callbackId: 3 transmitStatus: OK 13:24:45.882 DRIVER ACK received from node for current transaction. RTT = 51.47 ms 13:24:45.893 SERIAL « 0x0109000400020380033242 (11 bytes) 13:24:45.901 CNTRLR [Node 002] [~] [Battery] level: 50 => 50 [Endpoint 0] 13:24:45.913 CNTRLR [Node 002] [~] [Battery] isLow: false => false [Endpoint 0] 13:24:45.921 SERIAL » [ACK] (0x06) 13:24:45.923 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[BatteryCCReport] payload: 0x32 13:24:45.924 CNTRLR [Node 002] The node is now awake. 13:24:45.929 CNTRLR [Node 002] The node is ready to be used 13:24:45.931 DRIVER ACK already received, resolving transaction 13:24:45.932 DRIVER resuming send queue 13:24:45.939 CNTRLR « [Node 002] received response for battery information: level: 50 13:24:45.940 CNTRLR [Node 002] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 13:24:45.944 CNTRLR [Node 002] MultilevelSensorCC: doing a partial interview... 13:24:45.945 CNTRLR » [Node 002] querying Air temperature sensor reading... 13:24:45.950 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 4 └─[BatteryCCGet] 13:24:45.951 SERIAL » 0x0109001303028002250447 (11 bytes) 13:24:45.952 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:45.952 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:45.966 SERIAL « [ACK] (0x06) 13:24:45.967 DRIVER ACK received from controller for current transaction 13:24:45.968 SERIAL « 0x0104011301e8 (6 bytes) 13:24:45.969 SERIAL » [ACK] (0x06) 13:24:45.970 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:45.982 SERIAL « 0x0107001304000002ed (9 bytes) 13:24:45.983 SERIAL » [ACK] (0x06) 13:24:45.983 DRIVER « [REQ] [SendData] [confirmation] callbackId: 4 transmitStatus: OK 13:24:45.984 DRIVER ACK received from node for current transaction. RTT = 33.98 ms 13:24:46.013 SERIAL « 0x0109000400030380033c4d (11 bytes) 13:24:46.015 CNTRLR [Node 003] [~] [Battery] level: 60 => 60 [Endpoint 0] 13:24:46.024 CNTRLR [Node 003] [~] [Battery] isLow: false => false [Endpoint 0] 13:24:46.031 SERIAL » [ACK] (0x06) 13:24:46.032 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[BatteryCCReport] payload: 0x3c 13:24:46.033 CNTRLR [Node 003] The node is now awake. 13:24:46.035 CNTRLR [Node 003] The node is ready to be used 13:24:46.037 DRIVER ACK already received, resolving transaction 13:24:46.038 DRIVER resuming send queue 13:24:46.040 CNTRLR « [Node 003] received response for battery information: level: 60 13:24:46.041 CNTRLR [Node 003] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 13:24:46.044 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 5 └─[MultilevelSensorCCGet] 13:24:46.045 SERIAL » 0x010b00130204310401002505f5 (13 bytes) 13:24:46.046 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:46.235 SERIAL « [ACK] (0x06) 13:24:46.236 DRIVER ACK received from controller for current transaction 13:24:46.236 SERIAL « 0x0104011301e8 (6 bytes) 13:24:46.237 SERIAL » [ACK] (0x06) 13:24:46.237 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:46.254 CNTRLR [Node 003] MultilevelSensorCC: doing a partial interview... 13:24:46.256 CNTRLR » [Node 003] querying Air temperature sensor reading... 13:24:46.258 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:46.259 SERIAL « 0x0107001305000003ed (9 bytes) 13:24:46.259 SERIAL » [ACK] (0x06) 13:24:46.260 DRIVER « [REQ] [SendData] [confirmation] callbackId: 5 transmitStatus: OK 13:24:46.261 DRIVER ACK received from node for current transaction. RTT = 217.22 ms 13:24:46.266 SERIAL « 0x010c0004000206310501420920ad (14 bytes) 13:24:46.270 CNTRLR [Node 002] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 13:24:46.280 CNTRLR [Node 002] [~] [Multilevel Sensor] Air temperature: 23.36 => 23.3 [Endpoint 0] 6 13:24:46.287 SERIAL » [ACK] (0x06) 13:24:46.288 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[MultilevelSensorCCReport] payload: 0x01420920 13:24:46.289 DRIVER ACK already received, resolving transaction 13:24:46.289 DRIVER resuming send queue 13:24:46.290 CNTRLR « [Node 002] received current Air temperature sensor reading: 23.36 °C 13:24:46.292 CNTRLR [Node 002] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 13:24:46.296 CNTRLR [Node 002] ThermostatSetpointCC: doing a partial interview... 13:24:46.296 CNTRLR » [Node 002] querying current value of setpoint Heating... 13:24:46.300 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 6 └─[MultilevelSensorCCGet] 13:24:46.301 SERIAL » 0x010b00130304310401002506f7 (13 bytes) 13:24:46.302 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:46.307 SERIAL « [ACK] (0x06) 13:24:46.308 DRIVER ACK received from controller for current transaction 13:24:46.437 SERIAL « 0x0104011301e8 (6 bytes) 13:24:46.438 SERIAL » [ACK] (0x06) 13:24:46.439 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:46.442 SERIAL « 0x0107001306000002ef (9 bytes) 13:24:46.443 SERIAL » [ACK] (0x06) 13:24:46.444 DRIVER « [REQ] [SendData] [confirmation] callbackId: 6 transmitStatus: OK 13:24:46.445 DRIVER ACK received from node for current transaction. RTT = 144.68 ms 13:24:46.449 SERIAL « 0x010c00040003063105014207bd3f (14 bytes) 13:24:46.451 CNTRLR [Node 003] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 13:24:46.458 CNTRLR [Node 003] [~] [Multilevel Sensor] Air temperature: 19.63 => 19.8 [Endpoint 0] 1 13:24:46.465 SERIAL » [ACK] (0x06) 13:24:46.466 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[MultilevelSensorCCReport] payload: 0x014207bd 13:24:46.466 DRIVER ACK already received, resolving transaction 13:24:46.467 DRIVER resuming send queue 13:24:46.468 CNTRLR « [Node 003] received current Air temperature sensor reading: 19.81 °C 13:24:46.469 CNTRLR [Node 003] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 13:24:46.472 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 7 └─[ThermostatSetpointCCGet] 13:24:46.474 SERIAL » 0x010a00130203430201250785 (12 bytes) 13:24:46.492 SERIAL « [ACK] (0x06) 13:24:46.492 DRIVER ACK received from controller for current transaction 13:24:46.493 SERIAL « 0x0104011301e8 (6 bytes) 13:24:46.493 SERIAL » [ACK] (0x06) 13:24:46.493 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:46.501 CNTRLR [Node 003] ThermostatSetpointCC: doing a partial interview... 13:24:46.502 CNTRLR » [Node 003] querying current value of setpoint Heating... 13:24:46.507 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:46.509 SERIAL « 0x0107001307000002ee (9 bytes) 13:24:46.510 SERIAL » [ACK] (0x06) 13:24:46.511 DRIVER « [REQ] [SendData] [confirmation] callbackId: 7 transmitStatus: OK 13:24:46.512 DRIVER ACK received from node for current transaction. RTT = 39.91 ms 13:24:46.541 SERIAL « 0x010c00040002064303012200dc4c (14 bytes) 13:24:46.545 CNTRLR [Node 002] [~] [Thermostat Setpoint] setpoint[1]: 22 => 22 [Endpoint 0] 13:24:46.552 SERIAL » [ACK] (0x06) 13:24:46.553 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[ThermostatSetpointCCReport] payload: 0x012200dc 13:24:46.554 DRIVER ACK already received, resolving transaction 13:24:46.554 DRIVER resuming send queue 13:24:46.556 CNTRLR « [Node 002] received current value of setpoint Heating: 22 °C 13:24:46.556 CNTRLR » [Node 002] querying current value of setpoint Energy Save Heating... 13:24:46.559 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 8 └─[ThermostatSetpointCCGet] 13:24:46.559 SERIAL » 0x010a0013030343020125088b (12 bytes) 13:24:46.560 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:46.568 SERIAL « [ACK] (0x06) 13:24:46.569 DRIVER ACK received from controller for current transaction 13:24:46.572 SERIAL « 0x0104011301e8 (6 bytes) 13:24:46.573 SERIAL » [ACK] (0x06) 13:24:46.573 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:46.597 SERIAL « 0x0107001308000003e0 (9 bytes) 13:24:46.598 SERIAL » [ACK] (0x06) 13:24:46.599 DRIVER « [REQ] [SendData] [confirmation] callbackId: 8 transmitStatus: OK 13:24:46.600 DRIVER ACK received from node for current transaction. RTT = 41.51 ms 13:24:46.630 SERIAL « 0x010c0004000306430301220055c4 (14 bytes) 13:24:46.632 CNTRLR [Node 003] [~] [Thermostat Setpoint] setpoint[1]: 8.5 => 8.5 [Endpoint 0] 13:24:46.640 SERIAL » [ACK] (0x06) 13:24:46.641 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[ThermostatSetpointCCReport] payload: 0x01220055 13:24:46.641 DRIVER ACK already received, resolving transaction 13:24:46.641 DRIVER resuming send queue 13:24:46.643 CNTRLR « [Node 003] received current value of setpoint Heating: 8.5 °C 13:24:46.643 CNTRLR » [Node 003] querying current value of setpoint Energy Save Heating... 13:24:46.645 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 9 └─[ThermostatSetpointCCGet] 13:24:46.646 SERIAL » 0x010a0013020343020b250981 (12 bytes) 13:24:46.646 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:46.655 SERIAL « [ACK] (0x06) 13:24:46.656 DRIVER ACK received from controller for current transaction 13:24:46.659 SERIAL « 0x0104011301e8 (6 bytes) 13:24:46.660 SERIAL » [ACK] (0x06) 13:24:46.665 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:46.681 SERIAL « 0x0107001309000003e1 (9 bytes) 13:24:46.682 SERIAL » [ACK] (0x06) 13:24:46.684 DRIVER « [REQ] [SendData] [confirmation] callbackId: 9 transmitStatus: OK 13:24:46.684 DRIVER ACK received from node for current transaction. RTT = 39.30 ms 13:24:46.718 SERIAL « 0x010c000400020643030b2200b42e (14 bytes) 13:24:46.720 CNTRLR [Node 002] [~] [Thermostat Setpoint] setpoint[11]: 18 => 18 [Endpoint 0] 13:24:46.728 SERIAL » [ACK] (0x06) 13:24:46.729 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[ThermostatSetpointCCReport] payload: 0x0b2200b4 13:24:46.729 DRIVER ACK already received, resolving transaction 13:24:46.730 DRIVER resuming send queue 13:24:46.731 CNTRLR « [Node 002] received current value of setpoint Energy Save Heating: 18 °C 13:24:46.732 CNTRLR [Node 002] [~] [Thermostat Setpoint] interviewComplete [Endpoint 0] [internal] : true => true 13:24:46.735 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 10 └─[ThermostatSetpointCCGet] 13:24:46.736 SERIAL » 0x010a0013030343020b250a83 (12 bytes) 13:24:46.769 SERIAL « [ACK] (0x06) 13:24:46.770 DRIVER ACK received from controller for current transaction 13:24:46.771 SERIAL « 0x0104011301e8 (6 bytes) 13:24:46.771 SERIAL » [ACK] (0x06) 13:24:46.772 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:46.784 CNTRLR [Node 002] ConfigurationCC: Loading configuration parameters from device confi g 13:24:46.789 CNTRLR [Node 002] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 13:24:46.792 CNTRLR [Node 002] [Configuration] 1: metadata updated 13:24:46.801 CNTRLR [Node 002] [Configuration] 2: metadata updated 13:24:46.809 CNTRLR [Node 002] [Configuration] 3: metadata updated 13:24:46.817 CNTRLR [Node 002] [Configuration] 4: metadata updated 13:24:46.826 CNTRLR [Node 002] [Configuration] 5: metadata updated 13:24:46.834 CNTRLR [Node 002] [Configuration] 6: metadata updated 13:24:46.842 CNTRLR [Node 002] [Configuration] 7: metadata updated 13:24:46.851 CNTRLR [Node 002] [Configuration] 8: metadata updated 13:24:46.859 CNTRLR [Node 002] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 13:24:46.862 CNTRLR » [Node 002] querying parameter #1 value... 13:24:46.867 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:46.869 SERIAL « 0x010700130a000003e2 (9 bytes) 13:24:46.870 SERIAL » [ACK] (0x06) 13:24:46.871 DRIVER « [REQ] [SendData] [confirmation] callbackId: 10 transmitStatus: OK 13:24:46.872 DRIVER ACK received from node for current transaction. RTT = 136.64 ms 13:24:46.901 SERIAL « 0x010c000400030643030b2200b42f (14 bytes) 13:24:46.903 CNTRLR [Node 003] [~] [Thermostat Setpoint] setpoint[11]: 18 => 18 [Endpoint 0] 13:24:46.917 SERIAL » [ACK] (0x06) 13:24:46.918 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[ThermostatSetpointCCReport] payload: 0x0b2200b4 13:24:46.919 DRIVER ACK already received, resolving transaction 13:24:46.919 DRIVER resuming send queue 13:24:46.922 CNTRLR « [Node 003] received current value of setpoint Energy Save Heating: 18 °C 13:24:46.924 CNTRLR [Node 003] [~] [Thermostat Setpoint] interviewComplete [Endpoint 0] [internal] : true => true 13:24:46.926 CNTRLR [Node 003] ConfigurationCC: Loading configuration parameters from device confi g 13:24:46.929 CNTRLR [Node 003] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 13:24:46.931 CNTRLR [Node 003] [Configuration] 1: metadata updated 13:24:46.942 CNTRLR [Node 003] [Configuration] 2: metadata updated 13:24:46.952 CNTRLR [Node 003] [Configuration] 3: metadata updated 13:24:46.961 CNTRLR [Node 003] [Configuration] 4: metadata updated 13:24:46.970 CNTRLR [Node 003] [Configuration] 5: metadata updated 13:24:46.979 CNTRLR [Node 003] [Configuration] 6: metadata updated 13:24:46.988 CNTRLR [Node 003] [Configuration] 7: metadata updated 13:24:46.997 CNTRLR [Node 003] [Configuration] 8: metadata updated 13:24:47.005 CNTRLR [Node 003] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 13:24:47.007 CNTRLR » [Node 003] querying parameter #1 value... 13:24:47.021 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 11 └─[ConfigurationCCGet] 13:24:47.022 SERIAL » 0x010a00130203700501250bbd (12 bytes) 13:24:47.023 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:47.070 SERIAL « [ACK] (0x06) 13:24:47.071 DRIVER ACK received from controller for current transaction 13:24:47.072 SERIAL « 0x0104011301e8 (6 bytes) 13:24:47.073 SERIAL » [ACK] (0x06) 13:24:47.081 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:47.128 SERIAL « 0x010700130b000003e3 (9 bytes) 13:24:47.129 SERIAL » [ACK] (0x06) 13:24:47.130 DRIVER « [REQ] [SendData] [confirmation] callbackId: 11 transmitStatus: OK 13:24:47.131 DRIVER ACK received from node for current transaction. RTT = 110.37 ms 13:24:47.143 SERIAL « 0x010b0004000205700601010081 (13 bytes) 13:24:47.155 CNTRLR [Node 002] [~] [Configuration] 1: 0 => 0 13:24:47.165 SERIAL » [ACK] (0x06) 13:24:47.167 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x010100 13:24:47.167 DRIVER ACK already received, resolving transaction 13:24:47.167 DRIVER resuming send queue 13:24:47.168 CNTRLR « [Node 002] parameter #1 has value: 0 13:24:47.169 CNTRLR » [Node 002] querying parameter #2 value... 13:24:47.171 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 12 └─[ConfigurationCCGet] 13:24:47.171 SERIAL » 0x010a00130303700501250cbb (12 bytes) 13:24:47.172 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:47.196 SERIAL « [ACK] (0x06) 13:24:47.197 DRIVER ACK received from controller for current transaction 13:24:47.208 SERIAL « 0x0104011301e8 (6 bytes) 13:24:47.211 SERIAL » [ACK] (0x06) 13:24:47.214 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:47.219 SERIAL « 0x010700130c000003e4 (9 bytes) 13:24:47.220 SERIAL » [ACK] (0x06) 13:24:47.221 DRIVER « [REQ] [SendData] [confirmation] callbackId: 12 transmitStatus: OK 13:24:47.221 DRIVER ACK received from node for current transaction. RTT = 50.96 ms 13:24:47.240 SERIAL « 0x010b0004000305700601010080 (13 bytes) 13:24:47.245 CNTRLR [Node 003] [~] [Configuration] 1: 0 => 0 13:24:47.254 SERIAL » [ACK] (0x06) 13:24:47.255 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x010100 13:24:47.256 DRIVER ACK already received, resolving transaction 13:24:47.256 DRIVER resuming send queue 13:24:47.257 CNTRLR « [Node 003] parameter #1 has value: 0 13:24:47.257 CNTRLR » [Node 003] querying parameter #2 value... 13:24:47.259 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 13 └─[ConfigurationCCGet] 13:24:47.260 SERIAL » 0x010a00130203700502250db8 (12 bytes) 13:24:47.260 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:47.270 SERIAL « [ACK] (0x06) 13:24:47.271 DRIVER ACK received from controller for current transaction 13:24:47.280 SERIAL « 0x0104011301e8 (6 bytes) 13:24:47.281 SERIAL » [ACK] (0x06) 13:24:47.282 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:47.299 SERIAL « 0x010700130d000003e5 (9 bytes) 13:24:47.300 SERIAL » [ACK] (0x06) 13:24:47.301 DRIVER « [REQ] [SendData] [confirmation] callbackId: 13 transmitStatus: OK 13:24:47.301 DRIVER ACK received from node for current transaction. RTT = 42.28 ms 13:24:47.327 SERIAL « 0x010b0004000205700602010082 (13 bytes) 13:24:47.331 CNTRLR [Node 002] [~] [Configuration] 2: 0 => 0 13:24:47.343 SERIAL » [ACK] (0x06) 13:24:47.344 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x020100 13:24:47.345 DRIVER ACK already received, resolving transaction 13:24:47.345 DRIVER resuming send queue 13:24:47.346 CNTRLR « [Node 002] parameter #2 has value: 0 13:24:47.347 CNTRLR » [Node 002] querying parameter #3 value... 13:24:47.350 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 14 └─[ConfigurationCCGet] 13:24:47.351 SERIAL » 0x010a00130303700502250eba (12 bytes) 13:24:47.352 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:47.358 SERIAL « [ACK] (0x06) 13:24:47.359 DRIVER ACK received from controller for current transaction 13:24:47.369 SERIAL « 0x0104011301e8 (6 bytes) 13:24:47.370 SERIAL » [ACK] (0x06) 13:24:47.371 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:47.389 SERIAL « 0x010700130e000002e7 (9 bytes) 13:24:47.390 SERIAL » [ACK] (0x06) 13:24:47.391 DRIVER « [REQ] [SendData] [confirmation] callbackId: 14 transmitStatus: OK 13:24:47.392 DRIVER ACK received from node for current transaction. RTT = 41.68 ms 13:24:47.423 SERIAL « 0x010b0004000305700602010083 (13 bytes) 13:24:47.427 CNTRLR [Node 003] [~] [Configuration] 2: 0 => 0 13:24:47.435 SERIAL » [ACK] (0x06) 13:24:47.436 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x020100 13:24:47.436 DRIVER ACK already received, resolving transaction 13:24:47.436 DRIVER resuming send queue 13:24:47.437 CNTRLR « [Node 003] parameter #2 has value: 0 13:24:47.438 CNTRLR » [Node 003] querying parameter #3 value... 13:24:47.440 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 15 └─[ConfigurationCCGet] 13:24:47.440 SERIAL » 0x010a00130203700503250fbb (12 bytes) 13:24:47.441 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:47.447 SERIAL « [ACK] (0x06) 13:24:47.448 DRIVER ACK received from controller for current transaction 13:24:47.452 SERIAL « 0x0104011301e8 (6 bytes) 13:24:47.453 SERIAL » [ACK] (0x06) 13:24:47.454 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:47.476 SERIAL « 0x010700130f000003e7 (9 bytes) 13:24:47.477 SERIAL » [ACK] (0x06) 13:24:47.479 DRIVER « [REQ] [SendData] [confirmation] callbackId: 15 transmitStatus: OK 13:24:47.480 DRIVER ACK received from node for current transaction. RTT = 40.26 ms 13:24:47.520 SERIAL « 0x010b0004000205700603010182 (13 bytes) 13:24:47.524 CNTRLR [Node 002] [~] [Configuration] 3: 1 => 1 13:24:47.532 SERIAL » [ACK] (0x06) 13:24:47.534 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x030101 13:24:47.534 DRIVER ACK already received, resolving transaction 13:24:47.545 DRIVER resuming send queue 13:24:47.546 CNTRLR « [Node 002] parameter #3 has value: 1 13:24:47.550 CNTRLR » [Node 002] querying parameter #4 value... 13:24:47.552 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 16 └─[ConfigurationCCGet] 13:24:47.553 SERIAL » 0x010a001303037005032510a5 (12 bytes) 13:24:47.553 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:47.562 SERIAL « [ACK] (0x06) 13:24:47.563 DRIVER ACK received from controller for current transaction 13:24:47.575 SERIAL « 0x0104011301e8 (6 bytes) 13:24:47.576 SERIAL » [ACK] (0x06) 13:24:47.579 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:47.597 SERIAL « 0x0107001310000003f8 (9 bytes) 13:24:47.598 SERIAL » [ACK] (0x06) 13:24:47.599 DRIVER « [REQ] [SendData] [confirmation] callbackId: 16 transmitStatus: OK 13:24:47.600 DRIVER ACK received from node for current transaction. RTT = 48.03 ms 13:24:47.650 SERIAL « 0x010b0004000305700603010183 (13 bytes) 13:24:47.654 CNTRLR [Node 003] [~] [Configuration] 3: 1 => 1 13:24:47.663 SERIAL » [ACK] (0x06) 13:24:47.664 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x030101 13:24:47.665 DRIVER ACK already received, resolving transaction 13:24:47.665 DRIVER resuming send queue 13:24:47.666 CNTRLR « [Node 003] parameter #3 has value: 1 13:24:47.667 CNTRLR » [Node 003] querying parameter #4 value... 13:24:47.669 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 17 └─[ConfigurationCCGet] 13:24:47.670 SERIAL » 0x010a001302037005042511a2 (12 bytes) 13:24:47.670 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:47.677 SERIAL « [ACK] (0x06) 13:24:47.678 DRIVER ACK received from controller for current transaction 13:24:47.687 SERIAL « 0x0104011301e8 (6 bytes) 13:24:47.688 SERIAL » [ACK] (0x06) 13:24:47.689 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:47.704 SERIAL « 0x0107001311000003f9 (9 bytes) 13:24:47.705 SERIAL » [ACK] (0x06) 13:24:47.706 DRIVER « [REQ] [SendData] [confirmation] callbackId: 17 transmitStatus: OK 13:24:47.706 DRIVER ACK received from node for current transaction. RTT = 37.34 ms 13:24:47.735 SERIAL « 0x010b0004000205700604010185 (13 bytes) 13:24:47.738 CNTRLR [Node 002] [~] [Configuration] 4: 1 => 1 13:24:47.745 SERIAL » [ACK] (0x06) 13:24:47.746 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x040101 13:24:47.747 DRIVER ACK already received, resolving transaction 13:24:47.747 DRIVER resuming send queue 13:24:47.748 CNTRLR « [Node 002] parameter #4 has value: 1 13:24:47.748 CNTRLR » [Node 002] querying parameter #5 value... 13:24:47.750 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 18 └─[ConfigurationCCGet] 13:24:47.751 SERIAL » 0x010a001303037005042512a0 (12 bytes) 13:24:47.751 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:47.756 SERIAL « [ACK] (0x06) 13:24:47.757 DRIVER ACK received from controller for current transaction 13:24:47.764 SERIAL « 0x0104011301e8 (6 bytes) 13:24:47.765 SERIAL » [ACK] (0x06) 13:24:47.766 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:47.782 SERIAL « 0x0107001312000003fa (9 bytes) 13:24:47.783 SERIAL » [ACK] (0x06) 13:24:47.784 DRIVER « [REQ] [SendData] [confirmation] callbackId: 18 transmitStatus: OK 13:24:47.785 DRIVER ACK received from node for current transaction. RTT = 35.23 ms 13:24:47.818 SERIAL « 0x010b0004000305700604010184 (13 bytes) 13:24:47.821 CNTRLR [Node 003] [~] [Configuration] 4: 1 => 1 13:24:47.829 SERIAL » [ACK] (0x06) 13:24:47.830 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x040101 13:24:47.830 DRIVER ACK already received, resolving transaction 13:24:47.831 DRIVER resuming send queue 13:24:47.831 CNTRLR « [Node 003] parameter #4 has value: 1 13:24:47.832 CNTRLR » [Node 003] querying parameter #5 value... 13:24:47.833 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 19 └─[ConfigurationCCGet] 13:24:47.834 SERIAL » 0x010a001302037005052513a1 (12 bytes) 13:24:47.835 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:47.843 SERIAL « [ACK] (0x06) 13:24:47.844 DRIVER ACK received from controller for current transaction 13:24:47.847 SERIAL « 0x0104011301e8 (6 bytes) 13:24:47.849 SERIAL » [ACK] (0x06) 13:24:47.850 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:47.871 SERIAL « 0x0107001313000002fa (9 bytes) 13:24:47.872 SERIAL » [ACK] (0x06) 13:24:47.873 DRIVER « [REQ] [SendData] [confirmation] callbackId: 19 transmitStatus: OK 13:24:47.873 DRIVER ACK received from node for current transaction. RTT = 39.65 ms 13:24:47.899 SERIAL « 0x010b0004000205700605010580 (13 bytes) 13:24:47.902 CNTRLR [Node 002] [~] [Configuration] 5: 5 => 5 13:24:47.909 SERIAL » [ACK] (0x06) 13:24:47.910 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x050105 13:24:47.911 DRIVER ACK already received, resolving transaction 13:24:47.911 DRIVER resuming send queue 13:24:47.912 CNTRLR « [Node 002] parameter #5 has value: 5 13:24:47.912 CNTRLR » [Node 002] querying parameter #6 value... 13:24:47.914 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 20 └─[ConfigurationCCGet] 13:24:47.914 SERIAL » 0x010a001303037005052514a7 (12 bytes) 13:24:47.915 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:47.918 SERIAL « [ACK] (0x06) 13:24:47.919 DRIVER ACK received from controller for current transaction 13:24:47.927 SERIAL « 0x0104011301e8 (6 bytes) 13:24:47.928 SERIAL » [ACK] (0x06) 13:24:47.929 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:47.946 SERIAL « 0x0107001314000002fd (9 bytes) 13:24:47.946 SERIAL » [ACK] (0x06) 13:24:47.947 DRIVER « [REQ] [SendData] [confirmation] callbackId: 20 transmitStatus: OK 13:24:47.947 DRIVER ACK received from node for current transaction. RTT = 33.87 ms 13:24:47.980 SERIAL « 0x010b0004000305700605010581 (13 bytes) 13:24:47.983 CNTRLR [Node 003] [~] [Configuration] 5: 5 => 5 13:24:47.991 SERIAL » [ACK] (0x06) 13:24:47.991 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x050105 13:24:47.992 DRIVER ACK already received, resolving transaction 13:24:47.992 DRIVER resuming send queue 13:24:47.993 CNTRLR « [Node 003] parameter #5 has value: 5 13:24:47.993 CNTRLR » [Node 003] querying parameter #6 value... 13:24:47.995 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 21 └─[ConfigurationCCGet] 13:24:47.996 SERIAL » 0x010a001302037005062515a4 (12 bytes) 13:24:47.996 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:47.999 SERIAL « [ACK] (0x06) 13:24:48.000 DRIVER ACK received from controller for current transaction 13:24:48.006 SERIAL « 0x0104011301e8 (6 bytes) 13:24:48.007 SERIAL » [ACK] (0x06) 13:24:48.008 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:48.026 SERIAL « 0x0107001315000003fd (9 bytes) 13:24:48.027 SERIAL » [ACK] (0x06) 13:24:48.027 DRIVER « [REQ] [SendData] [confirmation] callbackId: 21 transmitStatus: OK 13:24:48.028 DRIVER ACK received from node for current transaction. RTT = 32.88 ms 13:24:48.060 SERIAL « 0x010b0004000205700606010086 (13 bytes) 13:24:48.063 CNTRLR [Node 002] [~] [Configuration] 6: 0 => 0 13:24:48.071 SERIAL » [ACK] (0x06) 13:24:48.072 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x060100 13:24:48.073 DRIVER ACK already received, resolving transaction 13:24:48.073 DRIVER resuming send queue 13:24:48.074 CNTRLR « [Node 002] parameter #6 has value: 0 13:24:48.074 CNTRLR » [Node 002] querying parameter #7 value... 13:24:48.076 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 22 └─[ConfigurationCCGet] 13:24:48.077 SERIAL » 0x010a001303037005062516a6 (12 bytes) 13:24:48.078 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:48.093 SERIAL « [ACK] (0x06) 13:24:48.094 DRIVER ACK received from controller for current transaction 13:24:48.097 SERIAL « 0x0104011301e8 (6 bytes) 13:24:48.098 SERIAL » [ACK] (0x06) 13:24:48.098 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:48.110 SERIAL « 0x0107001316000003fe (9 bytes) 13:24:48.111 SERIAL » [ACK] (0x06) 13:24:48.112 DRIVER « [REQ] [SendData] [confirmation] callbackId: 22 transmitStatus: OK 13:24:48.112 DRIVER ACK received from node for current transaction. RTT = 36.45 ms 13:24:48.147 SERIAL « 0x010b0004000305700606010087 (13 bytes) 13:24:48.150 CNTRLR [Node 003] [~] [Configuration] 6: 0 => 0 13:24:48.158 SERIAL » [ACK] (0x06) 13:24:48.159 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x060100 13:24:48.160 DRIVER ACK already received, resolving transaction 13:24:48.160 DRIVER resuming send queue 13:24:48.161 CNTRLR « [Node 003] parameter #6 has value: 0 13:24:48.161 CNTRLR » [Node 003] querying parameter #7 value... 13:24:48.163 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 23 └─[ConfigurationCCGet] 13:24:48.163 SERIAL » 0x010a001302037005072517a7 (12 bytes) 13:24:48.165 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:48.180 SERIAL « [ACK] (0x06) 13:24:48.180 DRIVER ACK received from controller for current transaction 13:24:48.181 SERIAL « 0x0104011301e8 (6 bytes) 13:24:48.181 SERIAL » [ACK] (0x06) 13:24:48.182 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:48.195 SERIAL « 0x0107001317000003ff (9 bytes) 13:24:48.196 SERIAL » [ACK] (0x06) 13:24:48.197 DRIVER « [REQ] [SendData] [confirmation] callbackId: 23 transmitStatus: OK 13:24:48.197 DRIVER ACK received from node for current transaction. RTT = 34.57 ms 13:24:48.230 SERIAL « 0x010b0004000205700607010285 (13 bytes) 13:24:48.233 CNTRLR [Node 002] [~] [Configuration] 7: 2 => 2 13:24:48.242 SERIAL » [ACK] (0x06) 13:24:48.243 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x070102 13:24:48.243 DRIVER ACK already received, resolving transaction 13:24:48.244 DRIVER resuming send queue 13:24:48.244 CNTRLR « [Node 002] parameter #7 has value: 2 13:24:48.245 CNTRLR » [Node 002] querying parameter #8 value... 13:24:48.246 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 24 └─[ConfigurationCCGet] 13:24:48.247 SERIAL » 0x010a001303037005072518a9 (12 bytes) 13:24:48.248 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:48.261 SERIAL « [ACK] (0x06) 13:24:48.261 DRIVER ACK received from controller for current transaction 13:24:48.263 SERIAL « 0x0104011301e8 (6 bytes) 13:24:48.263 SERIAL » [ACK] (0x06) 13:24:48.264 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:48.279 SERIAL « 0x0107001318000003f0 (9 bytes) 13:24:48.280 SERIAL » [ACK] (0x06) 13:24:48.281 DRIVER « [REQ] [SendData] [confirmation] callbackId: 24 transmitStatus: OK 13:24:48.281 DRIVER ACK received from node for current transaction. RTT = 34.95 ms 13:24:48.312 SERIAL « 0x010b0004000305700607010284 (13 bytes) 13:24:48.315 CNTRLR [Node 003] [~] [Configuration] 7: 2 => 2 13:24:48.323 SERIAL » [ACK] (0x06) 13:24:48.324 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x070102 13:24:48.324 DRIVER ACK already received, resolving transaction 13:24:48.325 DRIVER resuming send queue 13:24:48.325 CNTRLR « [Node 003] parameter #7 has value: 2 13:24:48.326 CNTRLR » [Node 003] querying parameter #8 value... 13:24:48.327 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 25 └─[ConfigurationCCGet] 13:24:48.328 SERIAL » 0x010a001302037005082519a6 (12 bytes) 13:24:48.328 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:48.331 SERIAL « [ACK] (0x06) 13:24:48.332 DRIVER ACK received from controller for current transaction 13:24:48.341 SERIAL « 0x0104011301e8 (6 bytes) 13:24:48.342 SERIAL » [ACK] (0x06) 13:24:48.342 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:48.359 SERIAL « 0x0107001319000003f1 (9 bytes) 13:24:48.360 SERIAL » [ACK] (0x06) 13:24:48.360 DRIVER « [REQ] [SendData] [confirmation] callbackId: 25 transmitStatus: OK 13:24:48.361 DRIVER ACK received from node for current transaction. RTT = 33.54 ms 13:24:48.391 SERIAL « 0x010b0004000205700608010088 (13 bytes) 13:24:48.394 CNTRLR [Node 002] [~] [Configuration] 8: 0 => 0 13:24:48.402 SERIAL » [ACK] (0x06) 13:24:48.403 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x080100 13:24:48.403 DRIVER ACK already received, resolving transaction 13:24:48.404 DRIVER resuming send queue 13:24:48.404 CNTRLR « [Node 002] parameter #8 has value: 0 13:24:48.405 CNTRLR [Node 002] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 13:24:48.407 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 26 └─[ConfigurationCCGet] 13:24:48.408 SERIAL » 0x010a00130303700508251aa4 (12 bytes) 13:24:48.418 SERIAL « [ACK] (0x06) 13:24:48.418 DRIVER ACK received from controller for current transaction 13:24:48.423 SERIAL « 0x0104011301e8 (6 bytes) 13:24:48.424 SERIAL » [ACK] (0x06) 13:24:48.425 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:48.433 CNTRLR [Node 002] ProtectionCC: doing a partial interview... 13:24:48.434 CNTRLR » [Node 002] querying protection status... 13:24:48.437 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:48.439 SERIAL « 0x010700131a000003f2 (9 bytes) 13:24:48.440 SERIAL » [ACK] (0x06) 13:24:48.441 DRIVER « [REQ] [SendData] [confirmation] callbackId: 26 transmitStatus: OK 13:24:48.441 DRIVER ACK received from node for current transaction. RTT = 34.68 ms 13:24:48.473 SERIAL « 0x010b0004000305700608010089 (13 bytes) 13:24:48.476 CNTRLR [Node 003] [~] [Configuration] 8: 0 => 0 13:24:48.484 SERIAL » [ACK] (0x06) 13:24:48.485 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x080100 13:24:48.486 DRIVER ACK already received, resolving transaction 13:24:48.486 DRIVER resuming send queue 13:24:48.486 CNTRLR « [Node 003] parameter #8 has value: 0 13:24:48.487 CNTRLR [Node 003] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 13:24:48.488 CNTRLR [Node 003] ProtectionCC: doing a partial interview... 13:24:48.489 CNTRLR » [Node 003] querying protection status... 13:24:48.491 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 27 └─[ProtectionCCGet] 13:24:48.491 SERIAL » 0x0109001302027502251bac (11 bytes) 13:24:48.492 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:48.494 SERIAL « [ACK] (0x06) 13:24:48.495 DRIVER ACK received from controller for current transaction 13:24:48.504 SERIAL « 0x0104011301e8 (6 bytes) 13:24:48.505 SERIAL » [ACK] (0x06) 13:24:48.506 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:48.521 SERIAL « 0x010700131b000002f2 (9 bytes) 13:24:48.522 SERIAL » [ACK] (0x06) 13:24:48.522 DRIVER « [REQ] [SendData] [confirmation] callbackId: 27 transmitStatus: OK 13:24:48.523 DRIVER ACK received from node for current transaction. RTT = 32.39 ms 13:24:48.554 SERIAL « 0x0109000400020375030085 (11 bytes) 13:24:48.557 CNTRLR [Node 002] [~] [Protection] local: 0 => 0 [Endpoint 0] 13:24:48.564 SERIAL » [ACK] (0x06) 13:24:48.565 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[ProtectionCCReport] payload: 0x00 13:24:48.565 DRIVER ACK already received, resolving transaction 13:24:48.565 DRIVER resuming send queue 13:24:48.567 CNTRLR « [Node 002] received protection status: local: Unprotected 13:24:48.569 CNTRLR [Node 002] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 13:24:48.571 CNTRLR [Node 002] ThermostatModeCC: doing a partial interview... 13:24:48.572 CNTRLR » [Node 002] querying current thermostat mode... 13:24:48.575 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 28 └─[ProtectionCCGet] 13:24:48.575 SERIAL » 0x0109001303027502251caa (11 bytes) 13:24:48.576 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:48.579 SERIAL « [ACK] (0x06) 13:24:48.580 DRIVER ACK received from controller for current transaction 13:24:48.586 SERIAL « 0x0104011301e8 (6 bytes) 13:24:48.587 SERIAL » [ACK] (0x06) 13:24:48.587 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:48.608 SERIAL « 0x010700131c000002f5 (9 bytes) 13:24:48.608 SERIAL » [ACK] (0x06) 13:24:48.609 DRIVER « [REQ] [SendData] [confirmation] callbackId: 28 transmitStatus: OK 13:24:48.609 DRIVER ACK received from node for current transaction. RTT = 34.81 ms 13:24:48.636 SERIAL « 0x0109000400030375030084 (11 bytes) 13:24:48.638 CNTRLR [Node 003] [~] [Protection] local: 0 => 0 [Endpoint 0] 13:24:48.645 SERIAL » [ACK] (0x06) 13:24:48.645 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[ProtectionCCReport] payload: 0x00 13:24:48.646 DRIVER ACK already received, resolving transaction 13:24:48.646 DRIVER resuming send queue 13:24:48.647 CNTRLR « [Node 003] received protection status: local: Unprotected 13:24:48.648 CNTRLR [Node 003] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 13:24:48.650 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 29 └─[ThermostatModeCCGet] 13:24:48.651 SERIAL » 0x0109001302024002251d9f (11 bytes) 13:24:48.689 SERIAL « [ACK] (0x06) 13:24:48.690 DRIVER ACK received from controller for current transaction 13:24:48.691 SERIAL « 0x0104011301e8 (6 bytes) 13:24:48.691 SERIAL » [ACK] (0x06) 13:24:48.692 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:48.704 CNTRLR [Node 003] ThermostatModeCC: doing a partial interview... 13:24:48.704 CNTRLR » [Node 003] querying current thermostat mode... 13:24:48.706 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:48.707 SERIAL « 0x010700131d000003f5 (9 bytes) 13:24:48.708 SERIAL » [ACK] (0x06) 13:24:48.708 DRIVER « [REQ] [SendData] [confirmation] callbackId: 29 transmitStatus: OK 13:24:48.709 DRIVER ACK received from node for current transaction. RTT = 58.95 ms 13:24:48.713 SERIAL « 0x010a000400020440030100b5 (12 bytes) 13:24:48.716 CNTRLR [Node 002] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 0] 13:24:48.725 SERIAL » [ACK] (0x06) 13:24:48.727 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[ThermostatModeCCReport] payload: 0x0100 13:24:48.728 DRIVER ACK already received, resolving transaction 13:24:48.728 DRIVER resuming send queue 13:24:48.730 CNTRLR « [Node 002] received current thermostat mode: Heat 13:24:48.731 CNTRLR [Node 002] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 0] [internal] ue => true 13:24:48.734 CNTRLR [Node 002] MultilevelSwitchCC: doing a partial interview... 13:24:48.735 CNTRLR » [Node 002] requesting current switch state... 13:24:48.739 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 30 └─[ThermostatModeCCGet] 13:24:48.741 SERIAL » 0x0109001303024002251e9d (11 bytes) 13:24:48.742 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:48.753 SERIAL « [ACK] (0x06) 13:24:48.753 DRIVER ACK received from controller for current transaction 13:24:48.755 SERIAL « 0x0104011301e8 (6 bytes) 13:24:48.755 SERIAL » [ACK] (0x06) 13:24:48.756 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:48.772 SERIAL « 0x010700131e000002f7 (9 bytes) 13:24:48.772 SERIAL » [ACK] (0x06) 13:24:48.773 DRIVER « [REQ] [SendData] [confirmation] callbackId: 30 transmitStatus: OK 13:24:48.774 DRIVER ACK received from node for current transaction. RTT = 34.85 ms 13:24:48.802 SERIAL « 0x010a000400030440030100b4 (12 bytes) 13:24:48.804 CNTRLR [Node 003] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 0] 13:24:48.810 SERIAL » [ACK] (0x06) 13:24:48.811 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[ThermostatModeCCReport] payload: 0x0100 13:24:48.812 DRIVER ACK already received, resolving transaction 13:24:48.812 DRIVER resuming send queue 13:24:48.813 CNTRLR « [Node 003] received current thermostat mode: Heat 13:24:48.814 CNTRLR [Node 003] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 0] [internal] ue => true 13:24:48.815 CNTRLR [Node 003] MultilevelSwitchCC: doing a partial interview... 13:24:48.816 CNTRLR » [Node 003] requesting current switch state... 13:24:48.818 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 31 └─[MultilevelSwitchCCGet] 13:24:48.818 SERIAL » 0x0109001302022602251ffb (11 bytes) 13:24:48.819 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:48.821 SERIAL « [ACK] (0x06) 13:24:48.822 DRIVER ACK received from controller for current transaction 13:24:48.828 SERIAL « 0x0104011301e8 (6 bytes) 13:24:48.828 SERIAL » [ACK] (0x06) 13:24:48.829 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:48.848 SERIAL « 0x010700131f000003f7 (9 bytes) 13:24:48.849 SERIAL » [ACK] (0x06) 13:24:48.849 DRIVER « [REQ] [SendData] [confirmation] callbackId: 31 transmitStatus: OK 13:24:48.850 DRIVER ACK received from node for current transaction. RTT = 32.49 ms 13:24:48.880 SERIAL « 0x010900040002032603fe28 (11 bytes) 13:24:48.883 CNTRLR [Node 002] [~] [Multilevel Switch] currentValue: "unknown" => "un [Endpoint 0] known" 13:24:48.889 SERIAL » [ACK] (0x06) 13:24:48.891 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[MultilevelSwitchCCReport] current value: unknown 13:24:48.891 DRIVER ACK already received, resolving transaction 13:24:48.892 DRIVER resuming send queue 13:24:48.893 CNTRLR [Node 002] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 13:24:48.895 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 32 └─[MultilevelSwitchCCGet] 13:24:48.896 SERIAL » 0x01090013030226022520c5 (11 bytes) 13:24:48.908 SERIAL « [ACK] (0x06) 13:24:48.908 DRIVER ACK received from controller for current transaction 13:24:48.909 SERIAL « 0x0104011301e8 (6 bytes) 13:24:48.909 SERIAL » [ACK] (0x06) 13:24:48.909 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:48.913 CNTRLR [Node 002] AssociationCC: doing a partial interview... 13:24:48.915 CNTRLR » [Node 002] querying association group #1... 13:24:48.918 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:48.925 SERIAL « 0x0107001320000003c8 (9 bytes) 13:24:48.926 SERIAL » [ACK] (0x06) 13:24:48.927 DRIVER « [REQ] [SendData] [confirmation] callbackId: 32 transmitStatus: OK 13:24:48.927 DRIVER ACK received from node for current transaction. RTT = 32.07 ms 13:24:48.958 SERIAL « 0x01090004000303260300d7 (11 bytes) 13:24:48.960 CNTRLR [Node 003] [~] [Multilevel Switch] currentValue: 0 => 0 [Endpoint 0] 13:24:48.966 SERIAL » [ACK] (0x06) 13:24:48.967 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[MultilevelSwitchCCReport] current value: 0 13:24:48.968 DRIVER ACK already received, resolving transaction 13:24:48.968 DRIVER resuming send queue 13:24:48.970 CNTRLR [Node 003] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 13:24:48.971 CNTRLR [Node 003] AssociationCC: doing a partial interview... 13:24:48.972 CNTRLR » [Node 003] querying association group #1... 13:24:48.974 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 33 └─[AssociationCCGet] groupId: 1 13:24:48.975 SERIAL » 0x010a00130203850201252165 (12 bytes) 13:24:48.975 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:48.978 SERIAL « [ACK] (0x06) 13:24:48.979 DRIVER ACK received from controller for current transaction 13:24:48.985 SERIAL « 0x0104011301e8 (6 bytes) 13:24:48.985 SERIAL » [ACK] (0x06) 13:24:48.986 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:49.005 SERIAL « 0x0107001321000003c9 (9 bytes) 13:24:49.006 SERIAL » [ACK] (0x06) 13:24:49.006 DRIVER « [REQ] [SendData] [confirmation] callbackId: 33 transmitStatus: OK 13:24:49.007 DRIVER ACK received from node for current transaction. RTT = 33.59 ms 13:24:49.024 SERIAL « 0x010c000400020685030101000174 (14 bytes) 13:24:49.026 SERIAL » [ACK] (0x06) 13:24:49.028 CNTRLR [Node 002] [~] [Association] maxNodes[1]: 1 => 1 [internal] 13:24:49.030 CNTRLR [Node 002] [~] [Association] nodeIds[1]: 1 => 1 [internal] 13:24:49.032 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[AssociationCCReport] groupId: 1 maxNodes: 1 nodeIds: 1 reportsToFollow: 0 13:24:49.032 DRIVER ACK already received, resolving transaction 13:24:49.033 DRIVER resuming send queue 13:24:49.033 CNTRLR « [Node 002] received information for association group #1: maximum # of nodes: 1 currently assigned nodes: 1 13:24:49.035 CNTRLR [Node 002] [~] [Association] hasLifeline: true => true [internal] 13:24:49.036 CNTRLR [Node 002] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 13:24:49.038 CNTRLR [Node 002] AssociationGroupInfoCC: doing a partial interview... 13:24:49.040 CNTRLR [Node 002] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 13:24:49.043 CNTRLR [Node 002] NotificationCC: doing a partial interview... 13:24:49.044 CNTRLR » [Node 002] querying notification status for Power Management... 13:24:49.048 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 34 └─[AssociationCCGet] groupId: 1 13:24:49.048 SERIAL » 0x010a00130303850201252267 (12 bytes) 13:24:49.049 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:49.052 SERIAL « [ACK] (0x06) 13:24:49.052 DRIVER ACK received from controller for current transaction 13:24:49.058 SERIAL « 0x0104011301e8 (6 bytes) 13:24:49.059 SERIAL » [ACK] (0x06) 13:24:49.059 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:49.078 SERIAL « 0x0107001322000003ca (9 bytes) 13:24:49.079 SERIAL » [ACK] (0x06) 13:24:49.080 DRIVER « [REQ] [SendData] [confirmation] callbackId: 34 transmitStatus: OK 13:24:49.080 DRIVER ACK received from node for current transaction. RTT = 33.14 ms 13:24:49.096 SERIAL « 0x010c000400030685030101000175 (14 bytes) 13:24:49.097 SERIAL » [ACK] (0x06) 13:24:49.099 CNTRLR [Node 003] [~] [Association] maxNodes[1]: 1 => 1 [internal] 13:24:49.100 CNTRLR [Node 003] [~] [Association] nodeIds[1]: 1 => 1 [internal] 13:24:49.100 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[AssociationCCReport] groupId: 1 maxNodes: 1 nodeIds: 1 reportsToFollow: 0 13:24:49.101 DRIVER ACK already received, resolving transaction 13:24:49.101 DRIVER resuming send queue 13:24:49.102 CNTRLR « [Node 003] received information for association group #1: maximum # of nodes: 1 currently assigned nodes: 1 13:24:49.103 CNTRLR [Node 003] [~] [Association] hasLifeline: true => true [internal] 13:24:49.104 CNTRLR [Node 003] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 13:24:49.105 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 35 └─[NotificationCCGet] 13:24:49.107 SERIAL » 0x010c00130205710400080025239c (14 bytes) 13:24:49.116 SERIAL « [ACK] (0x06) 13:24:49.116 DRIVER ACK received from controller for current transaction 13:24:49.118 SERIAL « 0x0104011301e8 (6 bytes) 13:24:49.118 SERIAL » [ACK] (0x06) 13:24:49.119 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:49.121 CNTRLR [Node 003] AssociationGroupInfoCC: doing a partial interview... 13:24:49.122 CNTRLR [Node 003] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 13:24:49.123 CNTRLR [Node 003] NotificationCC: doing a partial interview... 13:24:49.123 CNTRLR » [Node 003] querying notification status for Power Management... 13:24:49.125 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:49.137 SERIAL « 0x0107001323000003cb (9 bytes) 13:24:49.138 SERIAL » [ACK] (0x06) 13:24:49.138 DRIVER « [REQ] [SendData] [confirmation] callbackId: 35 transmitStatus: OK 13:24:49.139 DRIVER ACK received from node for current transaction. RTT = 33.72 ms 13:24:49.158 SERIAL « 0x010f00040002097105000000ff0800007c (17 bytes) 13:24:49.160 SERIAL » [ACK] (0x06) 13:24:49.161 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[NotificationCCReport] payload: 0x000000ff080000 13:24:49.161 DRIVER ACK already received, resolving transaction 13:24:49.162 DRIVER resuming send queue 13:24:49.173 CNTRLR » [Node 002] querying notification status for System... 13:24:49.175 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 36 └─[NotificationCCGet] 13:24:49.176 SERIAL » 0x010c00130305710400080025249a (14 bytes) 13:24:49.176 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:49.179 SERIAL « [ACK] (0x06) 13:24:49.180 DRIVER ACK received from controller for current transaction 13:24:49.185 SERIAL « 0x0104011301e8 (6 bytes) 13:24:49.186 SERIAL » [ACK] (0x06) 13:24:49.187 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:49.207 SERIAL « 0x0107001324000003cc (9 bytes) 13:24:49.208 SERIAL » [ACK] (0x06) 13:24:49.208 DRIVER « [REQ] [SendData] [confirmation] callbackId: 36 transmitStatus: OK 13:24:49.209 DRIVER ACK received from node for current transaction. RTT = 33.41 ms 13:24:49.227 SERIAL « 0x010f00040003097105000000ff0800007d (17 bytes) 13:24:49.228 SERIAL » [ACK] (0x06) 13:24:49.229 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[NotificationCCReport] payload: 0x000000ff080000 13:24:49.229 DRIVER ACK already received, resolving transaction 13:24:49.229 DRIVER resuming send queue 13:24:49.236 CNTRLR » [Node 003] querying notification status for System... 13:24:49.238 DRIVER » [Node 002] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 37 └─[NotificationCCGet] 13:24:49.238 SERIAL » 0x010c00130205710400090025259b (14 bytes) 13:24:49.239 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:49.242 SERIAL « [ACK] (0x06) 13:24:49.243 DRIVER ACK received from controller for current transaction 13:24:49.248 SERIAL « 0x0104011301e8 (6 bytes) 13:24:49.249 SERIAL » [ACK] (0x06) 13:24:49.250 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:49.269 SERIAL « 0x0107001325000003cd (9 bytes) 13:24:49.270 SERIAL » [ACK] (0x06) 13:24:49.270 DRIVER « [REQ] [SendData] [confirmation] callbackId: 37 transmitStatus: OK 13:24:49.271 DRIVER ACK received from node for current transaction. RTT = 33.24 ms 13:24:49.289 SERIAL « 0x010f00040002097105000000ff0900007d (17 bytes) 13:24:49.290 SERIAL » [ACK] (0x06) 13:24:49.291 DRIVER « [Node 002] [REQ] [ApplicationCommand] [final] └─[NotificationCCReport] payload: 0x000000ff090000 13:24:49.291 DRIVER ACK already received, resolving transaction 13:24:49.292 DRIVER resuming send queue 13:24:49.298 CNTRLR [Node 002] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 13:24:49.299 CNTRLR [Node 002] Interview stage completed: CommandClasses 13:24:49.300 CNTRLR [Node 002] Interview stage completed: OverwriteConfig 13:24:49.300 CNTRLR » [Node 002] requesting node neighbors... 13:24:49.301 DRIVER » [Node 002] [REQ] [GetRoutingInfo] [P: Controller] removeNonRepeaters: false removeBadLinks: false 13:24:49.302 SERIAL » 0x01070080020000007a (9 bytes) 13:24:49.302 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:49.306 SERIAL « [ACK] (0x06) 13:24:49.306 DRIVER ACK received from controller for current transaction 13:24:49.308 SERIAL « 0x01200180311a00000000000000000000000000000000000000000000000000000 (34 bytes) 075 13:24:49.309 SERIAL » [ACK] (0x06) 13:24:49.309 DRIVER « [RES] [GetRoutingInfo] [final] node ids: 1, 5, 6, 10, 12, 13 13:24:49.310 DRIVER ACK already received, resolving transaction 13:24:49.310 DRIVER resuming send queue 13:24:49.311 CNTRLR « [Node 002] node neighbors received: 1, 5, 6, 10, 12, 13 13:24:49.311 CNTRLR [Node 002] Interview stage completed: Neighbors 13:24:49.311 CNTRLR [Node 002] Interview completed 13:24:49.314 DRIVER » [Node 003] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 38 └─[NotificationCCGet] 13:24:49.315 SERIAL » 0x010c001303057104000900252699 (14 bytes) 13:24:49.318 SERIAL « [ACK] (0x06) 13:24:49.319 DRIVER ACK received from controller for current transaction 13:24:49.324 SERIAL « 0x0104011301e8 (6 bytes) 13:24:49.325 SERIAL » [ACK] (0x06) 13:24:49.326 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:49.345 SERIAL « 0x0107001326000003ce (9 bytes) 13:24:49.346 SERIAL » [ACK] (0x06) 13:24:49.346 DRIVER « [REQ] [SendData] [confirmation] callbackId: 38 transmitStatus: OK 13:24:49.348 DRIVER ACK received from node for current transaction. RTT = 33.94 ms 13:24:49.365 SERIAL « 0x010f00040003097105000000ff0900007c (17 bytes) 13:24:49.366 SERIAL » [ACK] (0x06) 13:24:49.367 DRIVER « [Node 003] [REQ] [ApplicationCommand] [final] └─[NotificationCCReport] payload: 0x000000ff090000 13:24:49.367 DRIVER ACK already received, resolving transaction 13:24:49.368 DRIVER resuming send queue 13:24:49.374 CNTRLR [Node 003] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 13:24:49.375 CNTRLR [Node 003] Interview stage completed: CommandClasses 13:24:49.375 CNTRLR [Node 003] Interview stage completed: OverwriteConfig 13:24:49.375 CNTRLR » [Node 003] requesting node neighbors... 13:24:49.377 DRIVER » [Node 003] [REQ] [GetRoutingInfo] [P: Controller] removeNonRepeaters: false removeBadLinks: false 13:24:49.377 SERIAL » 0x01070080030000007b (9 bytes) 13:24:49.378 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:49.380 SERIAL « [ACK] (0x06) 13:24:49.381 DRIVER ACK received from controller for current transaction 13:24:49.383 SERIAL « 0x01200180011a00000000000000000000000000000000000000000000000000000 (34 bytes) 045 13:24:49.384 SERIAL » [ACK] (0x06) 13:24:49.386 DRIVER « [RES] [GetRoutingInfo] [final] node ids: 1, 10, 12, 13 13:24:49.386 DRIVER ACK already received, resolving transaction 13:24:49.387 DRIVER resuming send queue 13:24:49.388 CNTRLR « [Node 003] node neighbors received: 1, 10, 12, 13 13:24:49.388 CNTRLR [Node 003] Interview stage completed: Neighbors 13:24:49.388 CNTRLR [Node 003] Interview completed 13:24:49.391 DRIVER » [Node 004] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 39 └─[NoOperationCC] 13:24:49.392 SERIAL » 0x010800130401002527e3 (10 bytes) 13:24:49.395 SERIAL « [ACK] (0x06) 13:24:49.395 DRIVER ACK received from controller for current transaction 13:24:49.401 SERIAL « 0x0104011301e8 (6 bytes) 13:24:49.402 SERIAL » [ACK] (0x06) 13:24:49.402 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:50.665 SERIAL « 0x010700132700007fb3 (9 bytes) 13:24:50.666 SERIAL » [ACK] (0x06) 13:24:50.667 DRIVER « [REQ] [SendData] [final] callbackId: 39 transmitStatus: OK 13:24:50.667 DRIVER ACK already received, resolving transaction 13:24:50.667 DRIVER resuming send queue 13:24:50.668 CNTRLR « [Node 004] ping successful 13:24:50.672 CNTRLR [Node 004] ManufacturerSpecificCC: doing a partial interview... 13:24:50.672 CNTRLR [Node 004] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 13:24:50.674 DRIVER » [Node 005] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 40 └─[NoOperationCC] 13:24:50.675 SERIAL » 0x010800130501002528ed (10 bytes) 13:24:50.684 SERIAL « [ACK] (0x06) 13:24:50.685 DRIVER ACK received from controller for current transaction 13:24:50.686 SERIAL « 0x0104011301e8 (6 bytes) 13:24:50.687 SERIAL » [ACK] (0x06) 13:24:50.687 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:50.689 CNTRLR [Node 004] VersionCC: doing a partial interview... 13:24:50.690 CNTRLR [Node 004] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 13:24:50.691 CNTRLR [Node 004] trying to load device config 13:24:50.705 CNTRLR [Node 004] device config loaded 13:24:50.706 CNTRLR [Node 004] ZWavePlusCC: doing a partial interview... 13:24:50.707 CNTRLR [Node 004] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 13:24:50.707 CNTRLR [Node 004] BatteryCC: doing a partial interview... 13:24:50.708 CNTRLR » [Node 004] querying battery status... 13:24:50.709 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:51.964 SERIAL « 0x010700132800008043 (9 bytes) 13:24:51.965 SERIAL » [ACK] (0x06) 13:24:51.965 DRIVER « [REQ] [SendData] [final] callbackId: 40 transmitStatus: OK 13:24:51.966 DRIVER ACK already received, resolving transaction 13:24:51.966 DRIVER resuming send queue 13:24:51.967 CNTRLR « [Node 005] ping successful 13:24:51.970 CNTRLR [Node 005] ManufacturerSpecificCC: doing a partial interview... 13:24:51.971 CNTRLR [Node 005] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 13:24:51.973 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 41 └─[BatteryCCGet] 13:24:51.974 SERIAL » 0x010900130402800225296d (11 bytes) 13:24:51.984 SERIAL « [ACK] (0x06) 13:24:51.984 DRIVER ACK received from controller for current transaction 13:24:51.985 SERIAL « 0x0104011301e8 (6 bytes) 13:24:51.985 SERIAL » [ACK] (0x06) 13:24:51.986 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:51.993 CNTRLR [Node 005] VersionCC: doing a partial interview... 13:24:51.994 CNTRLR [Node 005] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 13:24:51.995 CNTRLR [Node 005] trying to load device config 13:24:52.010 CNTRLR [Node 005] device config loaded 13:24:52.011 CNTRLR [Node 005] ZWavePlusCC: doing a partial interview... 13:24:52.011 CNTRLR [Node 005] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 13:24:52.012 CNTRLR [Node 005] BatteryCC: doing a partial interview... 13:24:52.012 CNTRLR » [Node 005] querying battery status... 13:24:52.013 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:52.015 SERIAL « 0x0107001329000002c0 (9 bytes) 13:24:52.015 SERIAL » [ACK] (0x06) 13:24:52.016 DRIVER « [REQ] [SendData] [confirmation] callbackId: 41 transmitStatus: OK 13:24:52.016 DRIVER ACK received from node for current transaction. RTT = 43.38 ms 13:24:52.035 SERIAL « 0x0109000400040380035026 (11 bytes) 13:24:52.036 CNTRLR [Node 004] [~] [Battery] level: 80 => 80 [Endpoint 0] 13:24:52.043 CNTRLR [Node 004] [~] [Battery] isLow: false => false [Endpoint 0] 13:24:52.050 SERIAL » [ACK] (0x06) 13:24:52.051 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[BatteryCCReport] payload: 0x50 13:24:52.052 CNTRLR [Node 004] The node is now awake. 13:24:52.054 CNTRLR [Node 004] The node is ready to be used 13:24:52.056 DRIVER ACK already received, resolving transaction 13:24:52.056 DRIVER resuming send queue 13:24:52.058 CNTRLR « [Node 004] received response for battery information: level: 80 13:24:52.059 CNTRLR [Node 004] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 13:24:52.061 CNTRLR [Node 004] MultilevelSensorCC: doing a partial interview... 13:24:52.061 CNTRLR » [Node 004] querying Air temperature sensor reading... 13:24:52.063 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 42 └─[BatteryCCGet] 13:24:52.064 SERIAL » 0x0109001305028002252a6f (11 bytes) 13:24:52.065 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:52.065 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:52.069 SERIAL « [ACK] (0x06) 13:24:52.069 DRIVER ACK received from controller for current transaction 13:24:52.075 SERIAL « 0x0104011301e8 (6 bytes) 13:24:52.076 SERIAL » [ACK] (0x06) 13:24:52.076 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:52.095 SERIAL « 0x010700132a000002c3 (9 bytes) 13:24:52.096 SERIAL » [ACK] (0x06) 13:24:52.097 DRIVER « [REQ] [SendData] [confirmation] callbackId: 42 transmitStatus: OK 13:24:52.098 DRIVER ACK received from node for current transaction. RTT = 34.51 ms 13:24:52.125 SERIAL « 0x0109000400050380034b3c (11 bytes) 13:24:52.127 CNTRLR [Node 005] [~] [Battery] level: 75 => 75 [Endpoint 0] 13:24:52.136 CNTRLR [Node 005] [~] [Battery] isLow: false => false [Endpoint 0] 13:24:52.145 SERIAL » [ACK] (0x06) 13:24:52.146 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[BatteryCCReport] payload: 0x4b 13:24:52.146 CNTRLR [Node 005] The node is now awake. 13:24:52.148 CNTRLR [Node 005] The node is ready to be used 13:24:52.150 DRIVER ACK already received, resolving transaction 13:24:52.150 DRIVER resuming send queue 13:24:52.152 CNTRLR « [Node 005] received response for battery information: level: 75 13:24:52.153 CNTRLR [Node 005] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 13:24:52.155 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 43 └─[MultilevelSensorCCGet] 13:24:52.156 SERIAL » 0x010b0013040431040100252bdd (13 bytes) 13:24:52.157 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:52.166 SERIAL « [ACK] (0x06) 13:24:52.167 DRIVER ACK received from controller for current transaction 13:24:52.168 SERIAL « 0x0104011301e8 (6 bytes) 13:24:52.169 SERIAL » [ACK] (0x06) 13:24:52.170 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:52.171 CNTRLR [Node 005] MultilevelSensorCC: doing a partial interview... 13:24:52.172 CNTRLR » [Node 005] querying Air temperature sensor reading... 13:24:52.174 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:52.187 SERIAL « 0x010700132b000003c3 (9 bytes) 13:24:52.188 SERIAL » [ACK] (0x06) 13:24:52.189 DRIVER « [REQ] [SendData] [confirmation] callbackId: 43 transmitStatus: OK 13:24:52.189 DRIVER ACK received from node for current transaction. RTT = 34.06 ms 13:24:52.221 SERIAL « 0x010c000400040631050142079114 (14 bytes) 13:24:52.237 CNTRLR [Node 004] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 13:24:52.256 CNTRLR [Node 004] [~] [Multilevel Sensor] Air temperature: 19.28 => 19.3 [Endpoint 0] 7 13:24:52.264 SERIAL » [ACK] (0x06) 13:24:52.267 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[MultilevelSensorCCReport] payload: 0x01420791 13:24:52.267 DRIVER ACK already received, resolving transaction 13:24:52.268 DRIVER resuming send queue 13:24:52.269 CNTRLR « [Node 004] received current Air temperature sensor reading: 19.37 °C 13:24:52.270 CNTRLR [Node 004] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 13:24:52.271 CNTRLR [Node 004] ThermostatSetpointCC: doing a partial interview... 13:24:52.271 CNTRLR » [Node 004] querying current value of setpoint Heating... 13:24:52.273 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 44 └─[MultilevelSensorCCGet] 13:24:52.274 SERIAL » 0x010b0013050431040100252cdb (13 bytes) 13:24:52.275 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:52.279 SERIAL « [ACK] (0x06) 13:24:52.280 DRIVER ACK received from controller for current transaction 13:24:52.285 SERIAL « 0x0104011301e8 (6 bytes) 13:24:52.286 SERIAL » [ACK] (0x06) 13:24:52.287 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:52.306 SERIAL « 0x010700132c000003c4 (9 bytes) 13:24:52.307 SERIAL » [ACK] (0x06) 13:24:52.308 DRIVER « [REQ] [SendData] [confirmation] callbackId: 44 transmitStatus: OK 13:24:52.308 DRIVER ACK received from node for current transaction. RTT = 34.94 ms 13:24:52.337 SERIAL « 0x010c00040005063105014206fb7e (14 bytes) 13:24:52.340 CNTRLR [Node 005] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 13:24:52.348 CNTRLR [Node 005] [~] [Multilevel Sensor] Air temperature: 17.79 => 17.8 [Endpoint 0] 7 13:24:52.355 SERIAL » [ACK] (0x06) 13:24:52.356 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[MultilevelSensorCCReport] payload: 0x014206fb 13:24:52.356 DRIVER ACK already received, resolving transaction 13:24:52.356 DRIVER resuming send queue 13:24:52.357 CNTRLR « [Node 005] received current Air temperature sensor reading: 17.87 °C 13:24:52.358 CNTRLR [Node 005] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 13:24:52.360 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 45 └─[ThermostatSetpointCCGet] 13:24:52.360 SERIAL » 0x010a00130403430201252da9 (12 bytes) 13:24:52.370 SERIAL « [ACK] (0x06) 13:24:52.371 DRIVER ACK received from controller for current transaction 13:24:52.371 SERIAL « 0x0104011301e8 (6 bytes) 13:24:52.372 SERIAL » [ACK] (0x06) 13:24:52.372 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:52.374 CNTRLR [Node 005] ThermostatSetpointCC: doing a partial interview... 13:24:52.375 CNTRLR » [Node 005] querying current value of setpoint Heating... 13:24:52.376 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:52.429 SERIAL « 0x010c000400040643030122005fc9 (14 bytes) 13:24:52.431 CNTRLR [Node 004] [~] [Thermostat Setpoint] setpoint[1]: 9.5 => 9.5 [Endpoint 0] 13:24:52.438 SERIAL » [ACK] (0x06) 13:24:52.439 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[ThermostatSetpointCCReport] payload: 0x0122005f 13:24:52.439 DRIVER ACK already received, resolving transaction 13:24:52.439 DRIVER resuming send queue 13:24:52.441 CNTRLR « [Node 004] received current value of setpoint Heating: 9.5 °C 13:24:52.441 CNTRLR » [Node 004] querying current value of setpoint Energy Save Heating... 13:24:52.443 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 46 └─[ThermostatSetpointCCGet] 13:24:52.443 SERIAL » 0x010a00130503430201252eab (12 bytes) 13:24:52.444 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:52.447 SERIAL « [ACK] (0x06) 13:24:52.448 DRIVER ACK received from controller for current transaction 13:24:52.454 SERIAL « 0x0104011301e8 (6 bytes) 13:24:52.455 SERIAL » [ACK] (0x06) 13:24:52.455 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:52.463 SERIAL « 0x010700132e000001c4 (9 bytes) 13:24:52.464 SERIAL » [ACK] (0x06) 13:24:52.465 DRIVER « [REQ] [SendData] [confirmation] callbackId: 46 transmitStatus: OK 13:24:52.465 DRIVER ACK received from node for current transaction. RTT = 22.59 ms 13:24:52.487 SERIAL « 0x010c000400040643030122005fc9 (14 bytes) 13:24:52.488 CNTRLR [Node 004] [~] [Thermostat Setpoint] setpoint[1]: 9.5 => 9.5 [Endpoint 0] 13:24:52.496 SERIAL » [ACK] (0x06) 13:24:52.497 DRIVER « [Node 004] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] payload: 0x0122005f 13:24:52.508 SERIAL « 0x010700132e000004c1 (9 bytes) 13:24:52.509 SERIAL » [ACK] (0x06) 13:24:52.510 DRIVER « [REQ] [SendData] [confirmation] callbackId: 46 transmitStatus: OK 13:24:52.510 DRIVER ACK received from node for current transaction. RTT = 67.72 ms 13:24:52.518 SERIAL « 0x010c0004000506430301220064f3 (14 bytes) 13:24:52.520 CNTRLR [Node 005] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 0] 13:24:52.527 SERIAL » [ACK] (0x06) 13:24:52.528 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[ThermostatSetpointCCReport] payload: 0x01220064 13:24:52.530 DRIVER ACK already received, resolving transaction 13:24:52.531 DRIVER resuming send queue 13:24:52.532 CNTRLR « [Node 005] received current value of setpoint Heating: 10 °C 13:24:52.533 CNTRLR » [Node 005] querying current value of setpoint Energy Save Heating... 13:24:52.535 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 47 └─[ThermostatSetpointCCGet] 13:24:52.535 SERIAL » 0x010a0013040343020b252fa1 (12 bytes) 13:24:52.536 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:52.549 SERIAL « [ACK] (0x06) 13:24:52.551 DRIVER ACK received from controller for current transaction 13:24:52.552 SERIAL « 0x0104011301e8 (6 bytes) 13:24:52.553 SERIAL » [ACK] (0x06) 13:24:52.553 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:52.580 SERIAL « 0x010700132f000003c7 (9 bytes) 13:24:52.581 SERIAL » [ACK] (0x06) 13:24:52.582 DRIVER « [REQ] [SendData] [confirmation] callbackId: 47 transmitStatus: OK 13:24:52.583 DRIVER ACK received from node for current transaction. RTT = 48.69 ms 13:24:52.604 SERIAL « 0x010c000400040643030b2200b428 (14 bytes) 13:24:52.607 CNTRLR [Node 004] [~] [Thermostat Setpoint] setpoint[11]: 18 => 18 [Endpoint 0] 13:24:52.616 SERIAL » [ACK] (0x06) 13:24:52.618 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[ThermostatSetpointCCReport] payload: 0x0b2200b4 13:24:52.618 DRIVER ACK already received, resolving transaction 13:24:52.620 DRIVER resuming send queue 13:24:52.621 CNTRLR « [Node 004] received current value of setpoint Energy Save Heating: 18 °C 13:24:52.623 CNTRLR [Node 004] [~] [Thermostat Setpoint] interviewComplete [Endpoint 0] [internal] : true => true 13:24:52.626 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 48 └─[ThermostatSetpointCCGet] 13:24:52.626 SERIAL » 0x010a0013050343020b2530bf (12 bytes) 13:24:52.885 SERIAL « [ACK] (0x06) 13:24:52.886 DRIVER ACK received from controller for current transaction 13:24:52.886 SERIAL « 0x0104011301e8 (6 bytes) 13:24:52.887 SERIAL » [ACK] (0x06) 13:24:52.888 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:52.892 CNTRLR [Node 004] ConfigurationCC: Loading configuration parameters from device confi g 13:24:52.894 CNTRLR [Node 004] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 13:24:52.896 CNTRLR [Node 004] [Configuration] 1: metadata updated 13:24:52.905 CNTRLR [Node 004] [Configuration] 2: metadata updated 13:24:52.916 CNTRLR [Node 004] [Configuration] 3: metadata updated 13:24:52.924 CNTRLR [Node 004] [Configuration] 4: metadata updated 13:24:52.932 CNTRLR [Node 004] [Configuration] 5: metadata updated 13:24:52.944 CNTRLR [Node 004] [Configuration] 6: metadata updated 13:24:52.952 CNTRLR [Node 004] [Configuration] 7: metadata updated 13:24:52.960 CNTRLR [Node 004] [Configuration] 8: metadata updated 13:24:52.968 CNTRLR [Node 004] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 13:24:52.969 CNTRLR » [Node 004] querying parameter #1 value... 13:24:52.971 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:52.981 SERIAL « 0x0107001330000003d8 (9 bytes) 13:24:52.982 SERIAL » [ACK] (0x06) 13:24:52.983 DRIVER « [REQ] [SendData] [confirmation] callbackId: 48 transmitStatus: OK 13:24:52.984 DRIVER ACK received from node for current transaction. RTT = 358.59 ms 13:24:52.993 SERIAL « 0x010c000400050643030b2200b429 (14 bytes) 13:24:52.995 CNTRLR [Node 005] [~] [Thermostat Setpoint] setpoint[11]: 18 => 18 [Endpoint 0] 13:24:53.013 SERIAL » [ACK] (0x06) 13:24:53.016 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[ThermostatSetpointCCReport] payload: 0x0b2200b4 13:24:53.017 DRIVER ACK already received, resolving transaction 13:24:53.017 DRIVER resuming send queue 13:24:53.019 CNTRLR « [Node 005] received current value of setpoint Energy Save Heating: 18 °C 13:24:53.021 CNTRLR [Node 005] [~] [Thermostat Setpoint] interviewComplete [Endpoint 0] [internal] : true => true 13:24:53.022 CNTRLR [Node 005] ConfigurationCC: Loading configuration parameters from device confi g 13:24:53.025 CNTRLR [Node 005] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 13:24:53.026 CNTRLR [Node 005] [Configuration] 1: metadata updated 13:24:53.035 CNTRLR [Node 005] [Configuration] 2: metadata updated 13:24:53.043 CNTRLR [Node 005] [Configuration] 3: metadata updated 13:24:53.052 CNTRLR [Node 005] [Configuration] 4: metadata updated 13:24:53.059 CNTRLR [Node 005] [Configuration] 5: metadata updated 13:24:53.068 CNTRLR [Node 005] [Configuration] 6: metadata updated 13:24:53.076 CNTRLR [Node 005] [Configuration] 7: metadata updated 13:24:53.084 CNTRLR [Node 005] [Configuration] 8: metadata updated 13:24:53.091 CNTRLR [Node 005] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 13:24:53.092 CNTRLR » [Node 005] querying parameter #1 value... 13:24:53.095 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 49 └─[ConfigurationCCGet] 13:24:53.096 SERIAL » 0x010a00130403700501253181 (12 bytes) 13:24:53.096 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:53.139 SERIAL « [ACK] (0x06) 13:24:53.140 DRIVER ACK received from controller for current transaction 13:24:53.140 SERIAL « 0x0104011301e8 (6 bytes) 13:24:53.141 SERIAL » [ACK] (0x06) 13:24:53.142 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:53.172 SERIAL « 0x0107001331000003d9 (9 bytes) 13:24:53.173 SERIAL » [ACK] (0x06) 13:24:53.175 DRIVER « [REQ] [SendData] [confirmation] callbackId: 49 transmitStatus: OK 13:24:53.175 DRIVER ACK received from node for current transaction. RTT = 81.09 ms 13:24:53.207 SERIAL « 0x010b0004000405700601010087 (13 bytes) 13:24:53.210 CNTRLR [Node 004] [~] [Configuration] 1: 0 => 0 13:24:53.218 SERIAL » [ACK] (0x06) 13:24:53.219 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x010100 13:24:53.219 DRIVER ACK already received, resolving transaction 13:24:53.219 DRIVER resuming send queue 13:24:53.220 CNTRLR « [Node 004] parameter #1 has value: 0 13:24:53.220 CNTRLR » [Node 004] querying parameter #2 value... 13:24:53.228 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 50 └─[ConfigurationCCGet] 13:24:53.229 SERIAL » 0x010a00130503700501253283 (12 bytes) 13:24:53.229 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:53.240 SERIAL « [ACK] (0x06) 13:24:53.241 DRIVER ACK received from controller for current transaction 13:24:53.241 SERIAL « 0x0104011301e8 (6 bytes) 13:24:53.242 SERIAL » [ACK] (0x06) 13:24:53.242 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:53.263 SERIAL « 0x0107001332000003da (9 bytes) 13:24:53.264 SERIAL » [ACK] (0x06) 13:24:53.266 DRIVER « [REQ] [SendData] [confirmation] callbackId: 50 transmitStatus: OK 13:24:53.266 DRIVER ACK received from node for current transaction. RTT = 38.40 ms 13:24:53.297 SERIAL « 0x010b0004000505700601010086 (13 bytes) 13:24:53.300 CNTRLR [Node 005] [~] [Configuration] 1: 0 => 0 13:24:53.307 SERIAL » [ACK] (0x06) 13:24:53.308 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x010100 13:24:53.308 DRIVER ACK already received, resolving transaction 13:24:53.309 DRIVER resuming send queue 13:24:53.309 CNTRLR « [Node 005] parameter #1 has value: 0 13:24:53.310 CNTRLR » [Node 005] querying parameter #2 value... 13:24:53.313 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 51 └─[ConfigurationCCGet] 13:24:53.314 SERIAL » 0x010a00130403700502253380 (12 bytes) 13:24:53.314 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:53.319 SERIAL « [ACK] (0x06) 13:24:53.320 DRIVER ACK received from controller for current transaction 13:24:53.328 SERIAL « 0x0104011301e8 (6 bytes) 13:24:53.328 SERIAL » [ACK] (0x06) 13:24:53.329 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:53.350 SERIAL « 0x0107001333000002da (9 bytes) 13:24:53.351 SERIAL » [ACK] (0x06) 13:24:53.352 DRIVER « [REQ] [SendData] [confirmation] callbackId: 51 transmitStatus: OK 13:24:53.352 DRIVER ACK received from node for current transaction. RTT = 39.44 ms 13:24:53.380 SERIAL « 0x010b0004000405700602010084 (13 bytes) 13:24:53.383 CNTRLR [Node 004] [~] [Configuration] 2: 0 => 0 13:24:53.395 SERIAL » [ACK] (0x06) 13:24:53.396 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x020100 13:24:53.397 DRIVER ACK already received, resolving transaction 13:24:53.397 DRIVER resuming send queue 13:24:53.398 CNTRLR « [Node 004] parameter #2 has value: 0 13:24:53.399 CNTRLR » [Node 004] querying parameter #3 value... 13:24:53.401 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 52 └─[ConfigurationCCGet] 13:24:53.401 SERIAL » 0x010a00130503700502253486 (12 bytes) 13:24:53.402 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:53.413 SERIAL « [ACK] (0x06) 13:24:53.421 DRIVER ACK received from controller for current transaction 13:24:53.422 SERIAL « 0x0104011301e8 (6 bytes) 13:24:53.422 SERIAL » [ACK] (0x06) 13:24:53.423 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:53.441 SERIAL « 0x0107001334000002dd (9 bytes) 13:24:53.442 SERIAL » [ACK] (0x06) 13:24:53.443 DRIVER « [REQ] [SendData] [confirmation] callbackId: 52 transmitStatus: OK 13:24:53.444 DRIVER ACK received from node for current transaction. RTT = 43.26 ms 13:24:53.471 SERIAL « 0x010b0004000505700602010085 (13 bytes) 13:24:53.474 CNTRLR [Node 005] [~] [Configuration] 2: 0 => 0 13:24:53.482 SERIAL » [ACK] (0x06) 13:24:53.483 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x020100 13:24:53.484 DRIVER ACK already received, resolving transaction 13:24:53.484 DRIVER resuming send queue 13:24:53.485 CNTRLR « [Node 005] parameter #2 has value: 0 13:24:53.485 CNTRLR » [Node 005] querying parameter #3 value... 13:24:53.487 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 53 └─[ConfigurationCCGet] 13:24:53.487 SERIAL » 0x010a00130403700503253587 (12 bytes) 13:24:53.488 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:53.493 SERIAL « [ACK] (0x06) 13:24:53.494 DRIVER ACK received from controller for current transaction 13:24:53.500 SERIAL « 0x0104011301e8 (6 bytes) 13:24:53.501 SERIAL » [ACK] (0x06) 13:24:53.502 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:53.522 SERIAL « 0x0107001335000003dd (9 bytes) 13:24:53.523 SERIAL » [ACK] (0x06) 13:24:53.524 DRIVER « [REQ] [SendData] [confirmation] callbackId: 53 transmitStatus: OK 13:24:53.525 DRIVER ACK received from node for current transaction. RTT = 38.05 ms 13:24:53.550 SERIAL « 0x010b0004000405700603010184 (13 bytes) 13:24:53.553 CNTRLR [Node 004] [~] [Configuration] 3: 1 => 1 13:24:53.562 SERIAL » [ACK] (0x06) 13:24:53.563 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x030101 13:24:53.563 DRIVER ACK already received, resolving transaction 13:24:53.563 DRIVER resuming send queue 13:24:53.564 CNTRLR « [Node 004] parameter #3 has value: 1 13:24:53.564 CNTRLR » [Node 004] querying parameter #4 value... 13:24:53.566 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 54 └─[ConfigurationCCGet] 13:24:53.567 SERIAL » 0x010a00130503700503253685 (12 bytes) 13:24:53.567 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:53.573 SERIAL « [ACK] (0x06) 13:24:53.575 DRIVER ACK received from controller for current transaction 13:24:53.576 SERIAL « 0x0104011301e8 (6 bytes) 13:24:53.577 SERIAL » [ACK] (0x06) 13:24:53.578 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:53.609 SERIAL « 0x0107001336000003de (9 bytes) 13:24:53.610 SERIAL » [ACK] (0x06) 13:24:53.611 DRIVER « [REQ] [SendData] [confirmation] callbackId: 54 transmitStatus: OK 13:24:53.612 DRIVER ACK received from node for current transaction. RTT = 45.86 ms 13:24:53.632 SERIAL « 0x010b0004000505700603010185 (13 bytes) 13:24:53.635 CNTRLR [Node 005] [~] [Configuration] 3: 1 => 1 13:24:53.643 SERIAL » [ACK] (0x06) 13:24:53.645 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x030101 13:24:53.646 DRIVER ACK already received, resolving transaction 13:24:53.646 DRIVER resuming send queue 13:24:53.647 CNTRLR « [Node 005] parameter #3 has value: 1 13:24:53.647 CNTRLR » [Node 005] querying parameter #4 value... 13:24:53.649 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 55 └─[ConfigurationCCGet] 13:24:53.649 SERIAL » 0x010a00130403700504253782 (12 bytes) 13:24:53.650 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:53.660 SERIAL « [ACK] (0x06) 13:24:53.661 DRIVER ACK received from controller for current transaction 13:24:53.661 SERIAL « 0x0104011301e8 (6 bytes) 13:24:53.661 SERIAL » [ACK] (0x06) 13:24:53.662 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:53.690 SERIAL « 0x0107001337000003df (9 bytes) 13:24:53.693 SERIAL » [ACK] (0x06) 13:24:53.694 DRIVER « [REQ] [SendData] [confirmation] callbackId: 55 transmitStatus: OK 13:24:53.695 DRIVER ACK received from node for current transaction. RTT = 46.27 ms 13:24:53.719 SERIAL « 0x010b0004000405700604010183 (13 bytes) 13:24:53.721 CNTRLR [Node 004] [~] [Configuration] 4: 1 => 1 13:24:53.729 SERIAL » [ACK] (0x06) 13:24:53.729 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x040101 13:24:53.730 DRIVER ACK already received, resolving transaction 13:24:53.730 DRIVER resuming send queue 13:24:53.731 CNTRLR « [Node 004] parameter #4 has value: 1 13:24:53.731 CNTRLR » [Node 004] querying parameter #5 value... 13:24:53.733 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 56 └─[ConfigurationCCGet] 13:24:53.733 SERIAL » 0x010a0013050370050425388c (12 bytes) 13:24:53.734 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:53.743 SERIAL « [ACK] (0x06) 13:24:53.744 DRIVER ACK received from controller for current transaction 13:24:53.751 SERIAL « 0x0104011301e8 (6 bytes) 13:24:53.752 SERIAL » [ACK] (0x06) 13:24:53.753 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:53.772 SERIAL « 0x0107001338000003d0 (9 bytes) 13:24:53.773 SERIAL » [ACK] (0x06) 13:24:53.774 DRIVER « [REQ] [SendData] [confirmation] callbackId: 56 transmitStatus: OK 13:24:53.775 DRIVER ACK received from node for current transaction. RTT = 42.25 ms 13:24:53.801 SERIAL « 0x010b0004000505700604010182 (13 bytes) 13:24:53.804 CNTRLR [Node 005] [~] [Configuration] 4: 1 => 1 13:24:53.811 SERIAL » [ACK] (0x06) 13:24:53.812 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x040101 13:24:53.812 DRIVER ACK already received, resolving transaction 13:24:53.813 DRIVER resuming send queue 13:24:53.813 CNTRLR « [Node 005] parameter #4 has value: 1 13:24:53.814 CNTRLR » [Node 005] querying parameter #5 value... 13:24:53.816 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 57 └─[ConfigurationCCGet] 13:24:53.816 SERIAL » 0x010a0013040370050525398d (12 bytes) 13:24:53.817 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:53.825 SERIAL « [ACK] (0x06) 13:24:53.826 DRIVER ACK received from controller for current transaction 13:24:53.827 SERIAL « 0x0104011301e8 (6 bytes) 13:24:53.828 SERIAL » [ACK] (0x06) 13:24:53.829 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:53.850 SERIAL « 0x0107001339000003d1 (9 bytes) 13:24:53.851 SERIAL » [ACK] (0x06) 13:24:53.852 DRIVER « [REQ] [SendData] [confirmation] callbackId: 57 transmitStatus: OK 13:24:53.852 DRIVER ACK received from node for current transaction. RTT = 37.11 ms 13:24:53.888 SERIAL « 0x010b0004000405700605010586 (13 bytes) 13:24:53.892 CNTRLR [Node 004] [~] [Configuration] 5: 5 => 5 13:24:53.900 SERIAL » [ACK] (0x06) 13:24:53.901 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x050105 13:24:53.901 DRIVER ACK already received, resolving transaction 13:24:53.901 DRIVER resuming send queue 13:24:53.902 CNTRLR « [Node 004] parameter #5 has value: 5 13:24:53.902 CNTRLR » [Node 004] querying parameter #6 value... 13:24:53.904 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 58 └─[ConfigurationCCGet] 13:24:53.905 SERIAL » 0x010a00130503700505253a8f (12 bytes) 13:24:53.905 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:53.916 SERIAL « [ACK] (0x06) 13:24:53.917 DRIVER ACK received from controller for current transaction 13:24:53.921 SERIAL « 0x0104011301e8 (6 bytes) 13:24:53.921 SERIAL » [ACK] (0x06) 13:24:53.922 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:53.949 SERIAL « 0x010700133a000003d2 (9 bytes) 13:24:53.950 SERIAL » [ACK] (0x06) 13:24:53.950 DRIVER « [REQ] [SendData] [confirmation] callbackId: 58 transmitStatus: OK 13:24:53.951 DRIVER ACK received from node for current transaction. RTT = 46.72 ms 13:24:53.971 SERIAL « 0x010b0004000505700605010587 (13 bytes) 13:24:53.974 CNTRLR [Node 005] [~] [Configuration] 5: 5 => 5 13:24:53.982 SERIAL » [ACK] (0x06) 13:24:53.983 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x050105 13:24:53.984 DRIVER ACK already received, resolving transaction 13:24:53.984 DRIVER resuming send queue 13:24:53.985 CNTRLR « [Node 005] parameter #5 has value: 5 13:24:53.985 CNTRLR » [Node 005] querying parameter #6 value... 13:24:53.987 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 59 └─[ConfigurationCCGet] 13:24:53.987 SERIAL » 0x010a00130403700506253b8c (12 bytes) 13:24:53.988 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:53.999 SERIAL « [ACK] (0x06) 13:24:54.000 DRIVER ACK received from controller for current transaction 13:24:54.000 SERIAL « 0x0104011301e8 (6 bytes) 13:24:54.001 SERIAL » [ACK] (0x06) 13:24:54.002 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:54.021 SERIAL « 0x010700133b000003d3 (9 bytes) 13:24:54.022 SERIAL » [ACK] (0x06) 13:24:54.023 DRIVER « [REQ] [SendData] [confirmation] callbackId: 59 transmitStatus: OK 13:24:54.023 DRIVER ACK received from node for current transaction. RTT = 36.21 ms 13:24:54.054 SERIAL « 0x010b0004000405700606010080 (13 bytes) 13:24:54.057 CNTRLR [Node 004] [~] [Configuration] 6: 0 => 0 13:24:54.075 SERIAL » [ACK] (0x06) 13:24:54.076 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x060100 13:24:54.076 DRIVER ACK already received, resolving transaction 13:24:54.077 DRIVER resuming send queue 13:24:54.078 CNTRLR « [Node 004] parameter #6 has value: 0 13:24:54.079 CNTRLR » [Node 004] querying parameter #7 value... 13:24:54.082 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 60 └─[ConfigurationCCGet] 13:24:54.083 SERIAL » 0x010a00130503700506253c8a (12 bytes) 13:24:54.084 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:54.089 SERIAL « [ACK] (0x06) 13:24:54.090 DRIVER ACK received from controller for current transaction 13:24:54.100 SERIAL « 0x0104011301e8 (6 bytes) 13:24:54.102 SERIAL » [ACK] (0x06) 13:24:54.102 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:54.124 SERIAL « 0x010700133c000003d4 (9 bytes) 13:24:54.125 SERIAL » [ACK] (0x06) 13:24:54.126 DRIVER « [REQ] [SendData] [confirmation] callbackId: 60 transmitStatus: OK 13:24:54.129 DRIVER ACK received from node for current transaction. RTT = 47.23 ms 13:24:54.152 SERIAL « 0x010b0004000505700606010081 (13 bytes) 13:24:54.156 CNTRLR [Node 005] [~] [Configuration] 6: 0 => 0 13:24:54.164 SERIAL » [ACK] (0x06) 13:24:54.165 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x060100 13:24:54.165 DRIVER ACK already received, resolving transaction 13:24:54.166 DRIVER resuming send queue 13:24:54.166 CNTRLR « [Node 005] parameter #6 has value: 0 13:24:54.166 CNTRLR » [Node 005] querying parameter #7 value... 13:24:54.168 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 61 └─[ConfigurationCCGet] 13:24:54.169 SERIAL » 0x010a00130403700507253d8b (12 bytes) 13:24:54.169 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:54.173 SERIAL « [ACK] (0x06) 13:24:54.174 DRIVER ACK received from controller for current transaction 13:24:54.184 SERIAL « 0x0104011301e8 (6 bytes) 13:24:54.184 SERIAL » [ACK] (0x06) 13:24:54.185 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:54.199 SERIAL « 0x010700133d000003d5 (9 bytes) 13:24:54.200 SERIAL » [ACK] (0x06) 13:24:54.200 DRIVER « [REQ] [SendData] [confirmation] callbackId: 61 transmitStatus: OK 13:24:54.201 DRIVER ACK received from node for current transaction. RTT = 32.76 ms 13:24:54.235 SERIAL « 0x010b0004000405700607010283 (13 bytes) 13:24:54.238 CNTRLR [Node 004] [~] [Configuration] 7: 2 => 2 13:24:54.245 SERIAL » [ACK] (0x06) 13:24:54.246 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x070102 13:24:54.246 DRIVER ACK already received, resolving transaction 13:24:54.247 DRIVER resuming send queue 13:24:54.247 CNTRLR « [Node 004] parameter #7 has value: 2 13:24:54.248 CNTRLR » [Node 004] querying parameter #8 value... 13:24:54.249 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 62 └─[ConfigurationCCGet] 13:24:54.250 SERIAL » 0x010a00130503700507253e89 (12 bytes) 13:24:54.250 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:54.258 SERIAL « [ACK] (0x06) 13:24:54.258 DRIVER ACK received from controller for current transaction 13:24:54.262 SERIAL « 0x0104011301e8 (6 bytes) 13:24:54.263 SERIAL » [ACK] (0x06) 13:24:54.264 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:54.280 SERIAL « 0x010700133e000003d6 (9 bytes) 13:24:54.281 SERIAL » [ACK] (0x06) 13:24:54.282 DRIVER « [REQ] [SendData] [confirmation] callbackId: 62 transmitStatus: OK 13:24:54.282 DRIVER ACK received from node for current transaction. RTT = 33.29 ms 13:24:54.313 SERIAL « 0x010b0004000505700607010282 (13 bytes) 13:24:54.316 CNTRLR [Node 005] [~] [Configuration] 7: 2 => 2 13:24:54.324 SERIAL » [ACK] (0x06) 13:24:54.325 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x070102 13:24:54.325 DRIVER ACK already received, resolving transaction 13:24:54.326 DRIVER resuming send queue 13:24:54.326 CNTRLR « [Node 005] parameter #7 has value: 2 13:24:54.327 CNTRLR » [Node 005] querying parameter #8 value... 13:24:54.328 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 63 └─[ConfigurationCCGet] 13:24:54.329 SERIAL » 0x010a00130403700508253f86 (12 bytes) 13:24:54.329 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:54.336 SERIAL « [ACK] (0x06) 13:24:54.337 DRIVER ACK received from controller for current transaction 13:24:54.342 SERIAL « 0x0104011301e8 (6 bytes) 13:24:54.343 SERIAL » [ACK] (0x06) 13:24:54.345 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:54.360 SERIAL « 0x010700133f000003d7 (9 bytes) 13:24:54.360 SERIAL » [ACK] (0x06) 13:24:54.361 DRIVER « [REQ] [SendData] [confirmation] callbackId: 63 transmitStatus: OK 13:24:54.361 DRIVER ACK received from node for current transaction. RTT = 33.23 ms 13:24:54.391 SERIAL « 0x010b000400040570060801008e (13 bytes) 13:24:54.393 CNTRLR [Node 004] [~] [Configuration] 8: 0 => 0 13:24:54.402 SERIAL » [ACK] (0x06) 13:24:54.403 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x080100 13:24:54.403 DRIVER ACK already received, resolving transaction 13:24:54.403 DRIVER resuming send queue 13:24:54.404 CNTRLR « [Node 004] parameter #8 has value: 0 13:24:54.405 CNTRLR [Node 004] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 13:24:54.406 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 64 └─[ConfigurationCCGet] 13:24:54.407 SERIAL » 0x010a001305037005082540f8 (12 bytes) 13:24:54.444 SERIAL « [ACK] (0x06) 13:24:54.445 DRIVER ACK received from controller for current transaction 13:24:54.446 SERIAL « 0x0104011301e8 (6 bytes) 13:24:54.446 SERIAL » [ACK] (0x06) 13:24:54.447 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:54.452 CNTRLR [Node 004] ProtectionCC: doing a partial interview... 13:24:54.452 CNTRLR » [Node 004] querying protection status... 13:24:54.455 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:54.456 SERIAL « 0x0107001340000003a8 (9 bytes) 13:24:54.457 SERIAL » [ACK] (0x06) 13:24:54.458 DRIVER « [REQ] [SendData] [confirmation] callbackId: 64 transmitStatus: OK 13:24:54.458 DRIVER ACK received from node for current transaction. RTT = 51.92 ms 13:24:54.472 SERIAL « 0x010b000400050570060801008f (13 bytes) 13:24:54.474 CNTRLR [Node 005] [~] [Configuration] 8: 0 => 0 13:24:54.481 SERIAL » [ACK] (0x06) 13:24:54.482 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x080100 13:24:54.483 DRIVER ACK already received, resolving transaction 13:24:54.483 DRIVER resuming send queue 13:24:54.484 CNTRLR « [Node 005] parameter #8 has value: 0 13:24:54.485 CNTRLR [Node 005] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 13:24:54.486 CNTRLR [Node 005] ProtectionCC: doing a partial interview... 13:24:54.486 CNTRLR » [Node 005] querying protection status... 13:24:54.487 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 65 └─[ProtectionCCGet] 13:24:54.488 SERIAL » 0x01090013040275022541f0 (11 bytes) 13:24:54.488 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:54.492 SERIAL « [ACK] (0x06) 13:24:54.493 DRIVER ACK received from controller for current transaction 13:24:54.500 SERIAL « 0x0104011301e8 (6 bytes) 13:24:54.501 SERIAL » [ACK] (0x06) 13:24:54.501 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:54.518 SERIAL « 0x0107001341000003a9 (9 bytes) 13:24:54.518 SERIAL » [ACK] (0x06) 13:24:54.519 DRIVER « [REQ] [SendData] [confirmation] callbackId: 65 transmitStatus: OK 13:24:54.519 DRIVER ACK received from node for current transaction. RTT = 32.02 ms 13:24:54.552 SERIAL « 0x0109000400040375030083 (11 bytes) 13:24:54.554 CNTRLR [Node 004] [~] [Protection] local: 0 => 0 [Endpoint 0] 13:24:54.561 SERIAL » [ACK] (0x06) 13:24:54.562 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[ProtectionCCReport] payload: 0x00 13:24:54.562 DRIVER ACK already received, resolving transaction 13:24:54.562 DRIVER resuming send queue 13:24:54.563 CNTRLR « [Node 004] received protection status: local: Unprotected 13:24:54.564 CNTRLR [Node 004] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 13:24:54.565 CNTRLR [Node 004] ThermostatModeCC: doing a partial interview... 13:24:54.565 CNTRLR » [Node 004] querying current thermostat mode... 13:24:54.567 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 66 └─[ProtectionCCGet] 13:24:54.567 SERIAL » 0x01090013050275022542f2 (11 bytes) 13:24:54.568 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:54.570 SERIAL « [ACK] (0x06) 13:24:54.571 DRIVER ACK received from controller for current transaction 13:24:54.577 SERIAL « 0x0104011301e8 (6 bytes) 13:24:54.577 SERIAL » [ACK] (0x06) 13:24:54.578 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:54.597 SERIAL « 0x0107001342000003aa (9 bytes) 13:24:54.598 SERIAL » [ACK] (0x06) 13:24:54.598 DRIVER « [REQ] [SendData] [confirmation] callbackId: 66 transmitStatus: OK 13:24:54.598 DRIVER ACK received from node for current transaction. RTT = 31.88 ms 13:24:54.628 SERIAL « 0x0109000400050375030082 (11 bytes) 13:24:54.630 CNTRLR [Node 005] [~] [Protection] local: 0 => 0 [Endpoint 0] 13:24:54.636 SERIAL » [ACK] (0x06) 13:24:54.637 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[ProtectionCCReport] payload: 0x00 13:24:54.637 DRIVER ACK already received, resolving transaction 13:24:54.638 DRIVER resuming send queue 13:24:54.639 CNTRLR « [Node 005] received protection status: local: Unprotected 13:24:54.640 CNTRLR [Node 005] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 13:24:54.641 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 67 └─[ThermostatModeCCGet] 13:24:54.642 SERIAL » 0x01090013040240022543c7 (11 bytes) 13:24:54.653 SERIAL « [ACK] (0x06) 13:24:54.654 DRIVER ACK received from controller for current transaction 13:24:54.654 SERIAL « 0x0104011301e8 (6 bytes) 13:24:54.654 SERIAL » [ACK] (0x06) 13:24:54.655 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:54.661 CNTRLR [Node 005] ThermostatModeCC: doing a partial interview... 13:24:54.662 CNTRLR » [Node 005] querying current thermostat mode... 13:24:54.663 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:54.671 SERIAL « 0x0107001343000002aa (9 bytes) 13:24:54.672 SERIAL » [ACK] (0x06) 13:24:54.672 DRIVER « [REQ] [SendData] [confirmation] callbackId: 67 transmitStatus: OK 13:24:54.673 DRIVER ACK received from node for current transaction. RTT = 31.78 ms 13:24:54.703 SERIAL « 0x010a000400040440030100b3 (12 bytes) 13:24:54.704 CNTRLR [Node 004] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 0] 13:24:54.711 SERIAL » [ACK] (0x06) 13:24:54.711 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[ThermostatModeCCReport] payload: 0x0100 13:24:54.712 DRIVER ACK already received, resolving transaction 13:24:54.712 DRIVER resuming send queue 13:24:54.713 CNTRLR « [Node 004] received current thermostat mode: Heat 13:24:54.714 CNTRLR [Node 004] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 0] [internal] ue => true 13:24:54.715 CNTRLR [Node 004] MultilevelSwitchCC: doing a partial interview... 13:24:54.715 CNTRLR » [Node 004] requesting current switch state... 13:24:54.717 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 68 └─[ThermostatModeCCGet] 13:24:54.717 SERIAL » 0x01090013050240022544c1 (11 bytes) 13:24:54.717 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:54.720 SERIAL « [ACK] (0x06) 13:24:54.721 DRIVER ACK received from controller for current transaction 13:24:54.727 SERIAL « 0x0104011301e8 (6 bytes) 13:24:54.727 SERIAL » [ACK] (0x06) 13:24:54.728 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:54.747 SERIAL « 0x0107001344000003ac (9 bytes) 13:24:54.747 SERIAL » [ACK] (0x06) 13:24:54.748 DRIVER « [REQ] [SendData] [confirmation] callbackId: 68 transmitStatus: OK 13:24:54.748 DRIVER ACK received from node for current transaction. RTT = 31.90 ms 13:24:54.777 SERIAL « 0x010a000400050440030100b2 (12 bytes) 13:24:54.779 CNTRLR [Node 005] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 0] 13:24:54.785 SERIAL » [ACK] (0x06) 13:24:54.786 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[ThermostatModeCCReport] payload: 0x0100 13:24:54.786 DRIVER ACK already received, resolving transaction 13:24:54.787 DRIVER resuming send queue 13:24:54.788 CNTRLR « [Node 005] received current thermostat mode: Heat 13:24:54.789 CNTRLR [Node 005] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 0] [internal] ue => true 13:24:54.790 CNTRLR [Node 005] MultilevelSwitchCC: doing a partial interview... 13:24:54.790 CNTRLR » [Node 005] requesting current switch state... 13:24:54.791 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 69 └─[MultilevelSwitchCCGet] 13:24:54.792 SERIAL » 0x01090013040226022545a7 (11 bytes) 13:24:54.792 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:54.795 SERIAL « [ACK] (0x06) 13:24:54.796 DRIVER ACK received from controller for current transaction 13:24:54.801 SERIAL « 0x0104011301e8 (6 bytes) 13:24:54.802 SERIAL » [ACK] (0x06) 13:24:54.802 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:54.823 SERIAL « 0x0107001345000002ac (9 bytes) 13:24:54.824 SERIAL » [ACK] (0x06) 13:24:54.825 DRIVER « [REQ] [SendData] [confirmation] callbackId: 69 transmitStatus: OK 13:24:54.825 DRIVER ACK received from node for current transaction. RTT = 34.08 ms 13:24:54.854 SERIAL « 0x01090004000403260300d0 (11 bytes) 13:24:54.855 CNTRLR [Node 004] [~] [Multilevel Switch] currentValue: 0 => 0 [Endpoint 0] 13:24:54.862 SERIAL » [ACK] (0x06) 13:24:54.863 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[MultilevelSwitchCCReport] current value: 0 13:24:54.863 DRIVER ACK already received, resolving transaction 13:24:54.863 DRIVER resuming send queue 13:24:54.865 CNTRLR [Node 004] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 13:24:54.867 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 70 └─[MultilevelSwitchCCGet] 13:24:54.867 SERIAL » 0x01090013050226022546a5 (11 bytes) 13:24:54.877 SERIAL « [ACK] (0x06) 13:24:54.878 DRIVER ACK received from controller for current transaction 13:24:54.880 SERIAL « 0x0104011301e8 (6 bytes) 13:24:54.880 SERIAL » [ACK] (0x06) 13:24:54.881 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:54.883 CNTRLR [Node 004] AssociationCC: doing a partial interview... 13:24:54.884 CNTRLR » [Node 004] querying association group #1... 13:24:54.885 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:54.896 SERIAL « 0x0107001346000003ae (9 bytes) 13:24:54.897 SERIAL » [ACK] (0x06) 13:24:54.898 DRIVER « [REQ] [SendData] [confirmation] callbackId: 70 transmitStatus: OK 13:24:54.898 DRIVER ACK received from node for current transaction. RTT = 31.69 ms 13:24:54.929 SERIAL « 0x01090004000503260300d1 (11 bytes) 13:24:54.931 CNTRLR [Node 005] [~] [Multilevel Switch] currentValue: 0 => 0 [Endpoint 0] 13:24:54.937 SERIAL » [ACK] (0x06) 13:24:54.938 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[MultilevelSwitchCCReport] current value: 0 13:24:54.938 DRIVER ACK already received, resolving transaction 13:24:54.938 DRIVER resuming send queue 13:24:54.940 CNTRLR [Node 005] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 13:24:54.941 CNTRLR [Node 005] AssociationCC: doing a partial interview... 13:24:54.941 CNTRLR » [Node 005] querying association group #1... 13:24:54.942 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 71 └─[AssociationCCGet] groupId: 1 13:24:54.943 SERIAL » 0x010a00130403850201254705 (12 bytes) 13:24:54.943 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:54.947 SERIAL « [ACK] (0x06) 13:24:54.948 DRIVER ACK received from controller for current transaction 13:24:54.953 SERIAL « 0x0104011301e8 (6 bytes) 13:24:54.954 SERIAL » [ACK] (0x06) 13:24:54.954 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:54.973 SERIAL « 0x0107001347000002ae (9 bytes) 13:24:54.974 SERIAL » [ACK] (0x06) 13:24:54.975 DRIVER « [REQ] [SendData] [confirmation] callbackId: 71 transmitStatus: OK 13:24:54.975 DRIVER ACK received from node for current transaction. RTT = 32.69 ms 13:24:54.992 SERIAL « 0x010c000400040685030101000172 (14 bytes) 13:24:54.993 SERIAL » [ACK] (0x06) 13:24:54.994 CNTRLR [Node 004] [~] [Association] maxNodes[1]: 1 => 1 [internal] 13:24:54.995 CNTRLR [Node 004] [~] [Association] nodeIds[1]: 1 => 1 [internal] 13:24:54.996 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[AssociationCCReport] groupId: 1 maxNodes: 1 nodeIds: 1 reportsToFollow: 0 13:24:54.996 DRIVER ACK already received, resolving transaction 13:24:54.996 DRIVER resuming send queue 13:24:54.997 CNTRLR « [Node 004] received information for association group #1: maximum # of nodes: 1 currently assigned nodes: 1 13:24:54.998 CNTRLR [Node 004] [~] [Association] hasLifeline: true => true [internal] 13:24:54.998 CNTRLR [Node 004] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 13:24:54.999 CNTRLR [Node 004] AssociationGroupInfoCC: doing a partial interview... 13:24:54.999 CNTRLR [Node 004] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 13:24:55.000 CNTRLR [Node 004] NotificationCC: doing a partial interview... 13:24:55.000 CNTRLR » [Node 004] querying notification status for Power Management... 13:24:55.002 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 72 └─[AssociationCCGet] groupId: 1 13:24:55.002 SERIAL » 0x010a0013050385020125480b (12 bytes) 13:24:55.003 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:55.006 SERIAL « [ACK] (0x06) 13:24:55.007 DRIVER ACK received from controller for current transaction 13:24:55.011 SERIAL « 0x0104011301e8 (6 bytes) 13:24:55.012 SERIAL » [ACK] (0x06) 13:24:55.013 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:55.033 SERIAL « 0x0107001348000002a1 (9 bytes) 13:24:55.034 SERIAL » [ACK] (0x06) 13:24:55.034 DRIVER « [REQ] [SendData] [confirmation] callbackId: 72 transmitStatus: OK 13:24:55.035 DRIVER ACK received from node for current transaction. RTT = 32.99 ms 13:24:55.052 SERIAL « 0x010c000400050685030101000173 (14 bytes) 13:24:55.053 SERIAL » [ACK] (0x06) 13:24:55.054 CNTRLR [Node 005] [~] [Association] maxNodes[1]: 1 => 1 [internal] 13:24:55.054 CNTRLR [Node 005] [~] [Association] nodeIds[1]: 1 => 1 [internal] 13:24:55.055 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[AssociationCCReport] groupId: 1 maxNodes: 1 nodeIds: 1 reportsToFollow: 0 13:24:55.055 DRIVER ACK already received, resolving transaction 13:24:55.055 DRIVER resuming send queue 13:24:55.056 CNTRLR « [Node 005] received information for association group #1: maximum # of nodes: 1 currently assigned nodes: 1 13:24:55.057 CNTRLR [Node 005] [~] [Association] hasLifeline: true => true [internal] 13:24:55.057 CNTRLR [Node 005] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 13:24:55.058 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 73 └─[NotificationCCGet] 13:24:55.059 SERIAL » 0x010c0013040571040008002549f0 (14 bytes) 13:24:55.068 SERIAL « [ACK] (0x06) 13:24:55.069 DRIVER ACK received from controller for current transaction 13:24:55.069 SERIAL « 0x0104011301e8 (6 bytes) 13:24:55.070 SERIAL » [ACK] (0x06) 13:24:55.070 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:55.071 CNTRLR [Node 005] AssociationGroupInfoCC: doing a partial interview... 13:24:55.072 CNTRLR [Node 005] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 13:24:55.073 CNTRLR [Node 005] NotificationCC: doing a partial interview... 13:24:55.073 CNTRLR » [Node 005] querying notification status for Power Management... 13:24:55.075 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:55.090 SERIAL « 0x0107001349000003a1 (9 bytes) 13:24:55.090 SERIAL » [ACK] (0x06) 13:24:55.091 DRIVER « [REQ] [SendData] [confirmation] callbackId: 73 transmitStatus: OK 13:24:55.091 DRIVER ACK received from node for current transaction. RTT = 32.86 ms 13:24:55.110 SERIAL « 0x010f00040004097105000000ff0800007a (17 bytes) 13:24:55.111 SERIAL » [ACK] (0x06) 13:24:55.111 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[NotificationCCReport] payload: 0x000000ff080000 13:24:55.112 DRIVER ACK already received, resolving transaction 13:24:55.112 DRIVER resuming send queue 13:24:55.118 CNTRLR » [Node 004] querying notification status for System... 13:24:55.126 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 74 └─[NotificationCCGet] 13:24:55.126 SERIAL » 0x010c001305057104000800254af2 (14 bytes) 13:24:55.127 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:55.130 SERIAL « [ACK] (0x06) 13:24:55.130 DRIVER ACK received from controller for current transaction 13:24:55.136 SERIAL « 0x0104011301e8 (6 bytes) 13:24:55.137 SERIAL » [ACK] (0x06) 13:24:55.137 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:55.158 SERIAL « 0x010700134a000003a2 (9 bytes) 13:24:55.158 SERIAL » [ACK] (0x06) 13:24:55.159 DRIVER « [REQ] [SendData] [confirmation] callbackId: 74 transmitStatus: OK 13:24:55.159 DRIVER ACK received from node for current transaction. RTT = 33.58 ms 13:24:55.177 SERIAL « 0x010f00040005097105000000ff0800007b (17 bytes) 13:24:55.178 SERIAL » [ACK] (0x06) 13:24:55.179 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[NotificationCCReport] payload: 0x000000ff080000 13:24:55.179 DRIVER ACK already received, resolving transaction 13:24:55.179 DRIVER resuming send queue 13:24:55.185 CNTRLR » [Node 005] querying notification status for System... 13:24:55.187 DRIVER » [Node 004] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 75 └─[NotificationCCGet] 13:24:55.188 SERIAL » 0x010c001304057104000900254bf3 (14 bytes) 13:24:55.188 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:55.191 SERIAL « [ACK] (0x06) 13:24:55.192 DRIVER ACK received from controller for current transaction 13:24:55.197 SERIAL « 0x0104011301e8 (6 bytes) 13:24:55.198 SERIAL » [ACK] (0x06) 13:24:55.199 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:55.218 SERIAL « 0x010700134b000003a3 (9 bytes) 13:24:55.219 SERIAL » [ACK] (0x06) 13:24:55.219 DRIVER « [REQ] [SendData] [confirmation] callbackId: 75 transmitStatus: OK 13:24:55.219 DRIVER ACK received from node for current transaction. RTT = 32.67 ms 13:24:55.239 SERIAL « 0x010f00040004097105000000ff0900007b (17 bytes) 13:24:55.240 SERIAL » [ACK] (0x06) 13:24:55.241 DRIVER « [Node 004] [REQ] [ApplicationCommand] [final] └─[NotificationCCReport] payload: 0x000000ff090000 13:24:55.241 DRIVER ACK already received, resolving transaction 13:24:55.241 DRIVER resuming send queue 13:24:55.248 CNTRLR [Node 004] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 13:24:55.248 CNTRLR [Node 004] Interview stage completed: CommandClasses 13:24:55.249 CNTRLR [Node 004] Interview stage completed: OverwriteConfig 13:24:55.249 CNTRLR » [Node 004] requesting node neighbors... 13:24:55.250 DRIVER » [Node 004] [REQ] [GetRoutingInfo] [P: Controller] removeNonRepeaters: false removeBadLinks: false 13:24:55.251 SERIAL » 0x01070080040000007c (9 bytes) 13:24:55.251 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:55.254 SERIAL « [ACK] (0x06) 13:24:55.255 DRIVER ACK received from controller for current transaction 13:24:55.256 SERIAL « 0x01200180311e00000000000000000000000000000000000000000000000000000 (34 bytes) 071 13:24:55.257 SERIAL » [ACK] (0x06) 13:24:55.258 DRIVER « [RES] [GetRoutingInfo] [final] node ids: 1, 5, 6, 10, 11, 12, 13 13:24:55.266 DRIVER ACK already received, resolving transaction 13:24:55.266 DRIVER resuming send queue 13:24:55.267 CNTRLR « [Node 004] node neighbors received: 1, 5, 6, 10, 11, 12, 13 13:24:55.267 CNTRLR [Node 004] Interview stage completed: Neighbors 13:24:55.268 CNTRLR [Node 004] Interview completed 13:24:55.270 DRIVER » [Node 005] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 76 └─[NotificationCCGet] 13:24:55.270 SERIAL » 0x010c001305057104000900254cf5 (14 bytes) 13:24:55.274 SERIAL « [ACK] (0x06) 13:24:55.275 DRIVER ACK received from controller for current transaction 13:24:55.280 SERIAL « 0x0104011301e8 (6 bytes) 13:24:55.281 SERIAL » [ACK] (0x06) 13:24:55.282 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:55.301 SERIAL « 0x010700134c000003a4 (9 bytes) 13:24:55.302 SERIAL » [ACK] (0x06) 13:24:55.303 DRIVER « [REQ] [SendData] [confirmation] callbackId: 76 transmitStatus: OK 13:24:55.303 DRIVER ACK received from node for current transaction. RTT = 33.75 ms 13:24:55.322 SERIAL « 0x010f00040005097105000000ff0900007a (17 bytes) 13:24:55.322 SERIAL » [ACK] (0x06) 13:24:55.323 DRIVER « [Node 005] [REQ] [ApplicationCommand] [final] └─[NotificationCCReport] payload: 0x000000ff090000 13:24:55.323 DRIVER ACK already received, resolving transaction 13:24:55.324 DRIVER resuming send queue 13:24:55.330 CNTRLR [Node 005] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 13:24:55.331 CNTRLR [Node 005] Interview stage completed: CommandClasses 13:24:55.331 CNTRLR [Node 005] Interview stage completed: OverwriteConfig 13:24:55.331 CNTRLR » [Node 005] requesting node neighbors... 13:24:55.332 DRIVER » [Node 005] [REQ] [GetRoutingInfo] [P: Controller] removeNonRepeaters: false removeBadLinks: false 13:24:55.333 SERIAL » 0x01070080050000007d (9 bytes) 13:24:55.333 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:55.336 SERIAL « [ACK] (0x06) 13:24:55.336 DRIVER ACK received from controller for current transaction 13:24:55.338 SERIAL « 0x012001802b1c00000000000000000000000000000000000000000000000000000 (34 bytes) 069 13:24:55.339 SERIAL » [ACK] (0x06) 13:24:55.340 DRIVER « [RES] [GetRoutingInfo] [final] node ids: 1, 2, 4, 6, 11, 12, 13 13:24:55.340 DRIVER ACK already received, resolving transaction 13:24:55.340 DRIVER resuming send queue 13:24:55.340 CNTRLR « [Node 005] node neighbors received: 1, 2, 4, 6, 11, 12, 13 13:24:55.341 CNTRLR [Node 005] Interview stage completed: Neighbors 13:24:55.341 CNTRLR [Node 005] Interview completed 13:24:55.342 DRIVER » [Node 006] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 77 └─[NoOperationCC] 13:24:55.343 SERIAL » 0x01080013060100254d8b (10 bytes) 13:24:55.346 SERIAL « [ACK] (0x06) 13:24:55.346 DRIVER ACK received from controller for current transaction 13:24:55.352 SERIAL « 0x0104011301e8 (6 bytes) 13:24:55.353 SERIAL » [ACK] (0x06) 13:24:55.353 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:56.647 SERIAL « 0x010700134d00008224 (9 bytes) 13:24:56.647 SERIAL » [ACK] (0x06) 13:24:56.648 DRIVER « [REQ] [SendData] [final] callbackId: 77 transmitStatus: OK 13:24:56.648 DRIVER ACK already received, resolving transaction 13:24:56.648 DRIVER resuming send queue 13:24:56.649 CNTRLR « [Node 006] ping successful 13:24:56.652 CNTRLR [Node 006] ManufacturerSpecificCC: doing a partial interview... 13:24:56.652 CNTRLR [Node 006] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 13:24:56.654 DRIVER » [Node 010] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 78 └─[NoOperationCC] 13:24:56.654 SERIAL » 0x010800130a0100254e84 (10 bytes) 13:24:56.662 SERIAL « [ACK] (0x06) 13:24:56.662 DRIVER ACK received from controller for current transaction 13:24:56.664 SERIAL « 0x0104011301e8 (6 bytes) 13:24:56.665 SERIAL » [ACK] (0x06) 13:24:56.665 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:56.667 CNTRLR [Node 006] VersionCC: doing a partial interview... 13:24:56.668 CNTRLR [Node 006] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 13:24:56.668 CNTRLR [Node 006] trying to load device config 13:24:56.682 CNTRLR [Node 006] device config loaded 13:24:56.683 CNTRLR [Node 006] ZWavePlusCC: doing a partial interview... 13:24:56.684 CNTRLR [Node 006] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 13:24:56.685 CNTRLR [Node 006] BatteryCC: doing a partial interview... 13:24:56.685 CNTRLR » [Node 006] querying battery status... 13:24:56.686 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:56.687 SERIAL « 0x010700134e000002a7 (9 bytes) 13:24:56.687 SERIAL » [ACK] (0x06) 13:24:56.688 DRIVER « [REQ] [SendData] [final] callbackId: 78 transmitStatus: OK 13:24:56.688 DRIVER ACK already received, resolving transaction 13:24:56.688 DRIVER resuming send queue 13:24:56.689 CNTRLR « [Node 010] ping successful 13:24:56.692 CNTRLR [Node 010] ManufacturerSpecificCC: doing a partial interview... 13:24:56.692 CNTRLR [Node 010] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 13:24:56.693 CNTRLR [Node 010] VersionCC: doing a partial interview... 13:24:56.693 CNTRLR [Node 010] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 13:24:56.694 CNTRLR [Node 010] trying to load device config 13:24:56.698 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 79 └─[BatteryCCGet] 13:24:56.699 SERIAL » 0x0109001306028002254f09 (11 bytes) 13:24:56.710 CNTRLR [Node 010] device config loaded 13:24:56.711 CNTRLR [Node 010] ZWavePlusCC: doing a partial interview... 13:24:56.712 CNTRLR [Node 010] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 13:24:56.715 CNTRLR [Node 010] BinarySwitchCC: doing a partial interview... 13:24:56.715 CNTRLR » [Node 010] querying Binary Switch state... 13:24:56.718 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:56.719 SERIAL « [ACK] (0x06) 13:24:56.719 DRIVER ACK received from controller for current transaction 13:24:56.719 SERIAL « 0x0104011301e8 (6 bytes) 13:24:56.720 SERIAL » [ACK] (0x06) 13:24:56.720 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:56.728 SERIAL « 0x010700134f000003a7 (9 bytes) 13:24:56.728 SERIAL » [ACK] (0x06) 13:24:56.729 DRIVER « [REQ] [SendData] [confirmation] callbackId: 79 transmitStatus: OK 13:24:56.729 DRIVER ACK received from node for current transaction. RTT = 31.59 ms 13:24:56.759 SERIAL « 0x0109000400060380035521 (11 bytes) 13:24:56.761 CNTRLR [Node 006] [~] [Battery] level: 85 => 85 [Endpoint 0] 13:24:56.768 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 0] 13:24:56.774 SERIAL » [ACK] (0x06) 13:24:56.775 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[BatteryCCReport] payload: 0x55 13:24:56.775 CNTRLR [Node 006] The node is now awake. 13:24:56.776 CNTRLR [Node 006] The node is ready to be used 13:24:56.778 DRIVER ACK already received, resolving transaction 13:24:56.780 DRIVER resuming send queue 13:24:56.782 CNTRLR « [Node 006] received response for battery information: level: 85 13:24:56.784 CNTRLR [Node 006] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 13:24:56.785 CNTRLR [Node 006] MultilevelSensorCC: doing a partial interview... 13:24:56.786 CNTRLR » [Node 006] querying Air temperature sensor reading... 13:24:56.788 DRIVER » [Node 010] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 80 └─[BinarySwitchCCGet] 13:24:56.788 SERIAL » 0x010900130a0225022550bf (11 bytes) 13:24:56.789 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:56.789 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:56.795 SERIAL « [ACK] (0x06) 13:24:56.797 DRIVER ACK received from controller for current transaction 13:24:56.802 SERIAL « 0x0104011301e8 (6 bytes) 13:24:56.802 SERIAL » [ACK] (0x06) 13:24:56.803 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:56.815 SERIAL « 0x0107001350000002b9 (9 bytes) 13:24:56.816 SERIAL » [ACK] (0x06) 13:24:56.816 DRIVER « [REQ] [SendData] [confirmation] callbackId: 80 transmitStatus: OK 13:24:56.817 DRIVER ACK received from node for current transaction. RTT = 29.40 ms 13:24:56.830 SERIAL « 0x01090004000a032503ff22 (11 bytes) 13:24:56.833 CNTRLR [Node 010] [~] [Binary Switch] currentValue: true => true [Endpoint 0] 13:24:56.840 SERIAL » [ACK] (0x06) 13:24:56.840 DRIVER « [Node 010] [REQ] [ApplicationCommand] [final] └─[BinarySwitchCCReport] payload: 0xff 13:24:56.841 CNTRLR [Node 010] The node is now awake. 13:24:56.842 CNTRLR [Node 010] The node is ready to be used 13:24:56.844 DRIVER ACK already received, resolving transaction 13:24:56.844 DRIVER resuming send queue 13:24:56.846 CNTRLR « [Node 010] received Binary Switch state: current value: true 13:24:56.854 CNTRLR [Node 010] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 13:24:56.856 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 81 └─[MultilevelSensorCCGet] 13:24:56.856 SERIAL » 0x010b00130604310401002551a5 (13 bytes) 13:24:56.857 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:56.988 SERIAL « [ACK] (0x06) 13:24:56.988 DRIVER ACK received from controller for current transaction 13:24:56.989 SERIAL « 0x0104011301e8 (6 bytes) 13:24:56.989 SERIAL » [ACK] (0x06) 13:24:56.989 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:56.997 CNTRLR [Node 010] MultilevelSwitchCC: doing a partial interview... 13:24:56.998 CNTRLR » [Node 010] requesting current switch state... 13:24:56.999 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:57.000 SERIAL « 0x0107001351000003b9 (9 bytes) 13:24:57.001 SERIAL » [ACK] (0x06) 13:24:57.001 DRIVER « [REQ] [SendData] [confirmation] callbackId: 81 transmitStatus: OK 13:24:57.002 DRIVER ACK received from node for current transaction. RTT = 146.30 ms 13:24:57.005 SERIAL « 0x010c00040006063105014207cf48 (14 bytes) 13:24:57.007 CNTRLR [Node 006] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 13:24:57.013 CNTRLR [Node 006] [~] [Multilevel Sensor] Air temperature: 19.99 => 19.9 [Endpoint 0] 9 13:24:57.020 SERIAL » [ACK] (0x06) 13:24:57.021 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[MultilevelSensorCCReport] payload: 0x014207cf 13:24:57.021 DRIVER ACK already received, resolving transaction 13:24:57.021 DRIVER resuming send queue 13:24:57.022 CNTRLR « [Node 006] received current Air temperature sensor reading: 19.99 °C 13:24:57.023 CNTRLR [Node 006] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 13:24:57.024 CNTRLR [Node 006] ThermostatSetpointCC: doing a partial interview... 13:24:57.024 CNTRLR » [Node 006] querying current value of setpoint Heating... 13:24:57.026 DRIVER » [Node 010] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 82 └─[MultilevelSwitchCCGet] 13:24:57.026 SERIAL » 0x010900130a0226022552be (11 bytes) 13:24:57.027 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:57.030 SERIAL « [ACK] (0x06) 13:24:57.031 DRIVER ACK received from controller for current transaction 13:24:57.036 SERIAL « 0x0104011301e8 (6 bytes) 13:24:57.037 SERIAL » [ACK] (0x06) 13:24:57.038 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:57.127 SERIAL « 0x0107001352000002bb (9 bytes) 13:24:57.128 SERIAL » [ACK] (0x06) 13:24:57.128 DRIVER « [REQ] [SendData] [confirmation] callbackId: 82 transmitStatus: OK 13:24:57.129 DRIVER ACK received from node for current transaction. RTT = 103.13 ms 13:24:57.131 SERIAL « 0x010b0004000a052603ffff00da (13 bytes) 13:24:57.133 CNTRLR [Node 010] [~] [Multilevel Switch] targetValue: 99 => 99 [Endpoint 0] 13:24:57.141 CNTRLR [Node 010] [~] [Multilevel Switch] duration: [Duration: 0seconds] [Endpoint 0] => [Duration: 0seconds] 13:24:57.148 CNTRLR [Node 010] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 0] 13:24:57.155 SERIAL » [ACK] (0x06) 13:24:57.155 DRIVER « [Node 010] [REQ] [ApplicationCommand] [final] └─[MultilevelSwitchCCReport] current value: 99 target value: 99 duration: [Duration: 0seconds] 13:24:57.156 DRIVER ACK already received, resolving transaction 13:24:57.156 DRIVER resuming send queue 13:24:57.158 CNTRLR [Node 010] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 13:24:57.160 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 83 └─[ThermostatSetpointCCGet] 13:24:57.160 SERIAL » 0x010a001306034302012553d5 (12 bytes) 13:24:57.178 SERIAL « [ACK] (0x06) 13:24:57.179 DRIVER ACK received from controller for current transaction 13:24:57.180 SERIAL « 0x0104011301e8 (6 bytes) 13:24:57.180 SERIAL » [ACK] (0x06) 13:24:57.180 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:57.184 CNTRLR [Node 010] ConfigurationCC: Loading configuration parameters from device confi g 13:24:57.186 CNTRLR [Node 010] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 13:24:57.187 CNTRLR [Node 010] [Configuration] 1: metadata updated 13:24:57.196 CNTRLR [Node 010] [Configuration] 2: metadata updated 13:24:57.204 CNTRLR [Node 010] [Configuration] 3: metadata updated 13:24:57.211 CNTRLR [Node 010] [Configuration] 4: metadata updated 13:24:57.219 CNTRLR [Node 010] [Configuration] 5: metadata updated 13:24:57.227 CNTRLR [Node 010] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 13:24:57.228 CNTRLR » [Node 010] querying parameter #1 value... 13:24:57.229 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:57.255 SERIAL « 0x0107001353000003bb (9 bytes) 13:24:57.256 SERIAL » [ACK] (0x06) 13:24:57.257 DRIVER « [REQ] [SendData] [confirmation] callbackId: 83 transmitStatus: OK 13:24:57.258 DRIVER ACK received from node for current transaction. RTT = 98.22 ms 13:24:57.261 SERIAL « 0x010c0004000606430301220069fd (14 bytes) 13:24:57.264 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpoint[1]: 10.5 => 10.5 [Endpoint 0] 13:24:57.272 SERIAL » [ACK] (0x06) 13:24:57.273 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[ThermostatSetpointCCReport] payload: 0x01220069 13:24:57.274 DRIVER ACK already received, resolving transaction 13:24:57.275 DRIVER resuming send queue 13:24:57.276 CNTRLR « [Node 006] received current value of setpoint Heating: 10.5 °C 13:24:57.277 CNTRLR » [Node 006] querying current value of setpoint Energy Save Heating... 13:24:57.279 DRIVER » [Node 010] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 84 └─[ConfigurationCCGet] 13:24:57.280 SERIAL » 0x010a00130a037005012554ea (12 bytes) 13:24:57.281 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:57.302 SERIAL « [ACK] (0x06) 13:24:57.302 DRIVER ACK received from controller for current transaction 13:24:57.303 SERIAL « 0x0104011301e8 (6 bytes) 13:24:57.303 SERIAL » [ACK] (0x06) 13:24:57.303 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:57.314 SERIAL « 0x0107001354000002bd (9 bytes) 13:24:57.315 SERIAL » [ACK] (0x06) 13:24:57.316 DRIVER « [REQ] [SendData] [confirmation] callbackId: 84 transmitStatus: OK 13:24:57.316 DRIVER ACK received from node for current transaction. RTT = 37.08 ms 13:24:57.323 SERIAL « 0x010b0004000a05700601010188 (13 bytes) 13:24:57.326 CNTRLR [Node 010] [~] [Configuration] 1: 1 => 1 13:24:57.333 SERIAL » [ACK] (0x06) 13:24:57.334 DRIVER « [Node 010] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x010101 13:24:57.335 DRIVER ACK already received, resolving transaction 13:24:57.335 DRIVER resuming send queue 13:24:57.335 CNTRLR « [Node 010] parameter #1 has value: 1 13:24:57.336 CNTRLR » [Node 010] querying parameter #2 value... 13:24:57.337 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 85 └─[ThermostatSetpointCCGet] 13:24:57.338 SERIAL » 0x010a0013060343020b2555d9 (12 bytes) 13:24:57.338 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:57.346 SERIAL « [ACK] (0x06) 13:24:57.347 DRIVER ACK received from controller for current transaction 13:24:57.349 SERIAL « 0x0104011301e8 (6 bytes) 13:24:57.350 SERIAL » [ACK] (0x06) 13:24:57.351 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:57.373 SERIAL « 0x0107001355000003bd (9 bytes) 13:24:57.374 SERIAL » [ACK] (0x06) 13:24:57.375 DRIVER « [REQ] [SendData] [confirmation] callbackId: 85 transmitStatus: OK 13:24:57.375 DRIVER ACK received from node for current transaction. RTT = 38.21 ms 13:24:57.409 SERIAL « 0x010c000400060643030b2200b42a (14 bytes) 13:24:57.410 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpoint[11]: 18 => 18 [Endpoint 0] 13:24:57.417 SERIAL » [ACK] (0x06) 13:24:57.417 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[ThermostatSetpointCCReport] payload: 0x0b2200b4 13:24:57.418 DRIVER ACK already received, resolving transaction 13:24:57.418 DRIVER resuming send queue 13:24:57.419 CNTRLR « [Node 006] received current value of setpoint Energy Save Heating: 18 °C 13:24:57.420 CNTRLR [Node 006] [~] [Thermostat Setpoint] interviewComplete [Endpoint 0] [internal] : true => true 13:24:57.421 DRIVER » [Node 010] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 86 └─[ConfigurationCCGet] 13:24:57.422 SERIAL » 0x010a00130a037005022556eb (12 bytes) 13:24:57.440 SERIAL « [ACK] (0x06) 13:24:57.440 DRIVER ACK received from controller for current transaction 13:24:57.441 SERIAL « 0x0104011301e8 (6 bytes) 13:24:57.441 SERIAL » [ACK] (0x06) 13:24:57.441 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:57.445 CNTRLR [Node 006] ConfigurationCC: Loading configuration parameters from device confi g 13:24:57.448 CNTRLR [Node 006] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 13:24:57.450 CNTRLR [Node 006] [Configuration] 1: metadata updated 13:24:57.457 CNTRLR [Node 006] [Configuration] 2: metadata updated 13:24:57.465 CNTRLR [Node 006] [Configuration] 3: metadata updated 13:24:57.473 CNTRLR [Node 006] [Configuration] 4: metadata updated 13:24:57.481 CNTRLR [Node 006] [Configuration] 5: metadata updated 13:24:57.489 CNTRLR [Node 006] [Configuration] 6: metadata updated 13:24:57.497 CNTRLR [Node 006] [Configuration] 7: metadata updated 13:24:57.505 CNTRLR [Node 006] [Configuration] 8: metadata updated 13:24:57.512 CNTRLR [Node 006] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 13:24:57.513 CNTRLR » [Node 006] querying parameter #1 value... 13:24:57.514 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:57.523 SERIAL « 0x0107001356000002bf (9 bytes) 13:24:57.525 SERIAL » [ACK] (0x06) 13:24:57.525 DRIVER « [REQ] [SendData] [confirmation] callbackId: 86 transmitStatus: OK 13:24:57.526 DRIVER ACK received from node for current transaction. RTT = 104.55 ms 13:24:57.562 SERIAL « 0x010b0004000a0570060201008a (13 bytes) 13:24:57.566 CNTRLR [Node 010] [~] [Configuration] 2: 0 => 0 13:24:57.574 SERIAL » [ACK] (0x06) 13:24:57.575 DRIVER « [Node 010] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x020100 13:24:57.576 DRIVER ACK already received, resolving transaction 13:24:57.577 DRIVER resuming send queue 13:24:57.577 CNTRLR « [Node 010] parameter #2 has value: 0 13:24:57.578 CNTRLR » [Node 010] querying parameter #3 value... 13:24:57.585 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 87 └─[ConfigurationCCGet] 13:24:57.586 SERIAL » 0x010a001306037005012557e5 (12 bytes) 13:24:57.586 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:57.614 SERIAL « [ACK] (0x06) 13:24:57.618 DRIVER ACK received from controller for current transaction 13:24:57.618 SERIAL « 0x0104011301e8 (6 bytes) 13:24:57.619 SERIAL » [ACK] (0x06) 13:24:57.619 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:57.630 SERIAL « 0x0107001357000002be (9 bytes) 13:24:57.631 SERIAL » [ACK] (0x06) 13:24:57.632 DRIVER « [REQ] [SendData] [confirmation] callbackId: 87 transmitStatus: OK 13:24:57.633 DRIVER ACK received from node for current transaction. RTT = 47.88 ms 13:24:57.678 SERIAL « 0x010b0004000605700601010085 (13 bytes) 13:24:57.681 CNTRLR [Node 006] [~] [Configuration] 1: 0 => 0 13:24:57.688 SERIAL » [ACK] (0x06) 13:24:57.689 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x010100 13:24:57.690 DRIVER ACK already received, resolving transaction 13:24:57.690 DRIVER resuming send queue 13:24:57.691 CNTRLR « [Node 006] parameter #1 has value: 0 13:24:57.691 CNTRLR » [Node 006] querying parameter #2 value... 13:24:57.693 DRIVER » [Node 010] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 88 └─[ConfigurationCCGet] 13:24:57.694 SERIAL » 0x010a00130a037005032558e4 (12 bytes) 13:24:57.694 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:57.702 SERIAL « [ACK] (0x06) 13:24:57.703 DRIVER ACK received from controller for current transaction 13:24:57.712 SERIAL « 0x0104011301e8 (6 bytes) 13:24:57.713 SERIAL » [ACK] (0x06) 13:24:57.713 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:57.813 SERIAL « 0x010700135800000bb8 (9 bytes) 13:24:57.814 SERIAL » [ACK] (0x06) 13:24:57.815 DRIVER « [REQ] [SendData] [confirmation] callbackId: 88 transmitStatus: OK 13:24:57.815 DRIVER ACK received from node for current transaction. RTT = 122.35 ms 13:24:57.858 SERIAL « 0x010b0004000a0570060301008b (13 bytes) 13:24:57.861 CNTRLR [Node 010] [~] [Configuration] 3: 0 => 0 13:24:57.869 SERIAL » [ACK] (0x06) 13:24:57.870 DRIVER « [Node 010] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x030100 13:24:57.871 DRIVER ACK already received, resolving transaction 13:24:57.871 DRIVER resuming send queue 13:24:57.871 CNTRLR « [Node 010] parameter #3 has value: 0 13:24:57.872 CNTRLR » [Node 010] querying parameter #4 value... 13:24:57.874 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 89 └─[ConfigurationCCGet] 13:24:57.875 SERIAL » 0x010a001306037005022559e8 (12 bytes) 13:24:57.875 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:57.881 SERIAL « [ACK] (0x06) 13:24:57.882 DRIVER ACK received from controller for current transaction 13:24:57.891 SERIAL « 0x0104011301e8 (6 bytes) 13:24:57.892 SERIAL » [ACK] (0x06) 13:24:57.893 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:57.910 SERIAL « 0x0107001359000003b1 (9 bytes) 13:24:57.911 SERIAL » [ACK] (0x06) 13:24:57.912 DRIVER « [REQ] [SendData] [confirmation] callbackId: 89 transmitStatus: OK 13:24:57.912 DRIVER ACK received from node for current transaction. RTT = 38.54 ms 13:24:57.940 SERIAL « 0x010b0004000605700602010086 (13 bytes) 13:24:57.942 CNTRLR [Node 006] [~] [Configuration] 2: 0 => 0 13:24:57.950 SERIAL » [ACK] (0x06) 13:24:57.951 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x020100 13:24:57.951 DRIVER ACK already received, resolving transaction 13:24:57.951 DRIVER resuming send queue 13:24:57.952 CNTRLR « [Node 006] parameter #2 has value: 0 13:24:57.952 CNTRLR » [Node 006] querying parameter #3 value... 13:24:57.954 DRIVER » [Node 010] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 90 └─[ConfigurationCCGet] 13:24:57.954 SERIAL » 0x010a00130a03700504255ae1 (12 bytes) 13:24:57.955 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:57.979 SERIAL « [ACK] (0x06) 13:24:57.979 DRIVER ACK received from controller for current transaction 13:24:57.980 SERIAL « 0x0104011301e8 (6 bytes) 13:24:57.981 SERIAL » [ACK] (0x06) 13:24:57.981 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:58.002 SERIAL « 0x010700135a000002b3 (9 bytes) 13:24:58.003 SERIAL » [ACK] (0x06) 13:24:58.005 DRIVER « [REQ] [SendData] [confirmation] callbackId: 90 transmitStatus: OK 13:24:58.006 DRIVER ACK received from node for current transaction. RTT = 52.33 ms 13:24:58.011 SERIAL « 0x010b0004000a0570060401018d (13 bytes) 13:24:58.014 CNTRLR [Node 010] [~] [Configuration] 4: 1 => 1 13:24:58.026 SERIAL » [ACK] (0x06) 13:24:58.028 DRIVER « [Node 010] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x040101 13:24:58.028 DRIVER ACK already received, resolving transaction 13:24:58.029 DRIVER resuming send queue 13:24:58.030 CNTRLR « [Node 010] parameter #4 has value: 1 13:24:58.031 CNTRLR » [Node 010] querying parameter #5 value... 13:24:58.033 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 91 └─[ConfigurationCCGet] 13:24:58.034 SERIAL » 0x010a00130603700503255beb (12 bytes) 13:24:58.037 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:58.041 SERIAL « [ACK] (0x06) 13:24:58.042 DRIVER ACK received from controller for current transaction 13:24:58.047 SERIAL « 0x0104011301e8 (6 bytes) 13:24:58.048 SERIAL » [ACK] (0x06) 13:24:58.048 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:58.067 SERIAL « 0x010700135b000003b3 (9 bytes) 13:24:58.068 SERIAL » [ACK] (0x06) 13:24:58.069 DRIVER « [REQ] [SendData] [confirmation] callbackId: 91 transmitStatus: OK 13:24:58.069 DRIVER ACK received from node for current transaction. RTT = 35.82 ms 13:24:58.102 SERIAL « 0x010b0004000605700603010186 (13 bytes) 13:24:58.104 CNTRLR [Node 006] [~] [Configuration] 3: 1 => 1 13:24:58.111 SERIAL » [ACK] (0x06) 13:24:58.112 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x030101 13:24:58.113 DRIVER ACK already received, resolving transaction 13:24:58.113 DRIVER resuming send queue 13:24:58.113 CNTRLR « [Node 006] parameter #3 has value: 1 13:24:58.114 CNTRLR » [Node 006] querying parameter #4 value... 13:24:58.115 DRIVER » [Node 010] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 92 └─[ConfigurationCCGet] 13:24:58.116 SERIAL » 0x010a00130a03700505255ce6 (12 bytes) 13:24:58.116 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:58.119 SERIAL « [ACK] (0x06) 13:24:58.120 DRIVER ACK received from controller for current transaction 13:24:58.126 SERIAL « 0x0104011301e8 (6 bytes) 13:24:58.126 SERIAL » [ACK] (0x06) 13:24:58.127 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:58.142 SERIAL « 0x010700135c000002b5 (9 bytes) 13:24:58.143 SERIAL » [ACK] (0x06) 13:24:58.143 DRIVER « [REQ] [SendData] [confirmation] callbackId: 92 transmitStatus: OK 13:24:58.144 DRIVER ACK received from node for current transaction. RTT = 28.66 ms 13:24:58.156 SERIAL « 0x010b0004000a0570060501018c (13 bytes) 13:24:58.159 CNTRLR [Node 010] [~] [Configuration] 5: 1 => 1 13:24:58.166 SERIAL » [ACK] (0x06) 13:24:58.167 DRIVER « [Node 010] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x050101 13:24:58.167 DRIVER ACK already received, resolving transaction 13:24:58.167 DRIVER resuming send queue 13:24:58.168 CNTRLR « [Node 010] parameter #5 has value: 1 13:24:58.168 CNTRLR [Node 010] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 13:24:58.170 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 93 └─[ConfigurationCCGet] 13:24:58.170 SERIAL » 0x010a00130603700504255dea (12 bytes) 13:24:58.178 SERIAL « [ACK] (0x06) 13:24:58.179 DRIVER ACK received from controller for current transaction 13:24:58.181 SERIAL « 0x0104011301e8 (6 bytes) 13:24:58.182 SERIAL » [ACK] (0x06) 13:24:58.183 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:58.189 CNTRLR [Node 010] AssociationCC: doing a partial interview... 13:24:58.189 CNTRLR [Node 010] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 13:24:58.190 CNTRLR [Node 010] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 13:24:58.196 CNTRLR [Node 010] MultiChannelAssociationCC: doing a partial interview... 13:24:58.197 CNTRLR » [Node 010] querying multi channel association group #1... 13:24:58.200 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:58.201 SERIAL « 0x010700135d000003b5 (9 bytes) 13:24:58.202 SERIAL » [ACK] (0x06) 13:24:58.203 DRIVER « [REQ] [SendData] [confirmation] callbackId: 93 transmitStatus: OK 13:24:58.203 DRIVER ACK received from node for current transaction. RTT = 33.27 ms 13:24:58.234 SERIAL « 0x010b0004000605700604010181 (13 bytes) 13:24:58.237 CNTRLR [Node 006] [~] [Configuration] 4: 1 => 1 13:24:58.244 SERIAL » [ACK] (0x06) 13:24:58.245 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x040101 13:24:58.245 DRIVER ACK already received, resolving transaction 13:24:58.265 DRIVER resuming send queue 13:24:58.266 CNTRLR « [Node 006] parameter #4 has value: 1 13:24:58.266 CNTRLR » [Node 006] querying parameter #5 value... 13:24:58.269 DRIVER » [Node 010] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 94 └─[MultiChannelAssociationCCGet] group id: 1 13:24:58.270 SERIAL » 0x010a00130a038e0201255e19 (12 bytes) 13:24:58.271 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:58.274 SERIAL « [ACK] (0x06) 13:24:58.275 DRIVER ACK received from controller for current transaction 13:24:58.281 SERIAL « 0x0104011301e8 (6 bytes) 13:24:58.282 SERIAL » [ACK] (0x06) 13:24:58.283 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:58.296 SERIAL « 0x010700135e000003b6 (9 bytes) 13:24:58.297 SERIAL » [ACK] (0x06) 13:24:58.298 DRIVER « [REQ] [SendData] [confirmation] callbackId: 94 transmitStatus: OK 13:24:58.298 DRIVER ACK received from node for current transaction. RTT = 29.79 ms 13:24:58.313 SERIAL « 0x010e0004000a088e030105000001007f (16 bytes) 13:24:58.316 SERIAL » [ACK] (0x06) 13:24:58.318 CNTRLR [Node 010] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 13:24:58.326 CNTRLR [Node 010] [~] [Multi Channel Association] nodeIds[1]: => 13:24:58.337 CNTRLR [Node 010] [~] [Multi Channel Association] endpoints[1]: [object Object] => [o bject Object] 13:24:58.347 DRIVER « [Node 010] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: endpoints: 1:0 13:24:58.348 DRIVER ACK already received, resolving transaction 13:24:58.348 DRIVER resuming send queue 13:24:58.349 CNTRLR « [Node 010] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 1:0 13:24:58.350 CNTRLR » [Node 010] querying multi channel association group #2... 13:24:58.352 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 95 └─[ConfigurationCCGet] 13:24:58.353 SERIAL » 0x010a00130603700505255fe9 (12 bytes) 13:24:58.353 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:58.365 SERIAL « [ACK] (0x06) 13:24:58.366 DRIVER ACK received from controller for current transaction 13:24:58.366 SERIAL « 0x0104011301e8 (6 bytes) 13:24:58.367 SERIAL » [ACK] (0x06) 13:24:58.367 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:58.385 SERIAL « 0x010700135f000002b6 (9 bytes) 13:24:58.386 SERIAL » [ACK] (0x06) 13:24:58.386 DRIVER « [REQ] [SendData] [confirmation] callbackId: 95 transmitStatus: OK 13:24:58.387 DRIVER ACK received from node for current transaction. RTT = 35.24 ms 13:24:58.418 SERIAL « 0x010b0004000605700605010584 (13 bytes) 13:24:58.420 CNTRLR [Node 006] [~] [Configuration] 5: 5 => 5 13:24:58.428 SERIAL » [ACK] (0x06) 13:24:58.429 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x050105 13:24:58.430 DRIVER ACK already received, resolving transaction 13:24:58.430 DRIVER resuming send queue 13:24:58.431 CNTRLR « [Node 006] parameter #5 has value: 5 13:24:58.431 CNTRLR » [Node 006] querying parameter #6 value... 13:24:58.433 DRIVER » [Node 010] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 96 └─[MultiChannelAssociationCCGet] group id: 2 13:24:58.434 SERIAL » 0x010a00130a038e0202256024 (12 bytes) 13:24:58.435 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:58.440 SERIAL « [ACK] (0x06) 13:24:58.440 DRIVER ACK received from controller for current transaction 13:24:58.446 SERIAL « 0x0104011301e8 (6 bytes) 13:24:58.447 SERIAL » [ACK] (0x06) 13:24:58.447 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:58.460 SERIAL « 0x010700136000000289 (9 bytes) 13:24:58.461 SERIAL » [ACK] (0x06) 13:24:58.462 DRIVER « [REQ] [SendData] [confirmation] callbackId: 96 transmitStatus: OK 13:24:58.462 DRIVER ACK received from node for current transaction. RTT = 29.17 ms 13:24:58.477 SERIAL « 0x010b0004000a058e0302050075 (13 bytes) 13:24:58.478 SERIAL » [ACK] (0x06) 13:24:58.479 CNTRLR [Node 010] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 13:24:58.487 CNTRLR [Node 010] [~] [Multi Channel Association] nodeIds[2]: => 13:24:58.494 CNTRLR [Node 010] [~] [Multi Channel Association] endpoints[2]: => 13:24:58.502 DRIVER « [Node 010] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 13:24:58.502 DRIVER ACK already received, resolving transaction 13:24:58.503 DRIVER resuming send queue 13:24:58.503 CNTRLR « [Node 010] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 13:24:58.505 CNTRLR [Node 010] [~] [Association] hasLifeline: true => true [internal] 13:24:58.505 CNTRLR [Node 010] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 13:24:58.506 CNTRLR [Node 010] AssociationGroupInfoCC: doing a partial interview... 13:24:58.507 CNTRLR [Node 010] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 13:24:58.508 CNTRLR [Node 010] Interview stage completed: CommandClasses 13:24:58.508 CNTRLR [Node 010] Interview stage completed: OverwriteConfig 13:24:58.508 CNTRLR » [Node 010] requesting node neighbors... 13:24:58.509 DRIVER » [Node 010] [REQ] [GetRoutingInfo] [P: Controller] removeNonRepeaters: false removeBadLinks: false 13:24:58.510 SERIAL » 0x010700800a00000072 (9 bytes) 13:24:58.510 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:58.513 SERIAL « [ACK] (0x06) 13:24:58.514 DRIVER ACK received from controller for current transaction 13:24:58.515 SERIAL « 0x012001800f1000000000000000000000000000000000000000000000000000000 (34 bytes) 041 13:24:58.516 SERIAL » [ACK] (0x06) 13:24:58.517 DRIVER « [RES] [GetRoutingInfo] [final] node ids: 1, 2, 3, 4, 13 13:24:58.517 DRIVER ACK already received, resolving transaction 13:24:58.517 DRIVER resuming send queue 13:24:58.518 CNTRLR « [Node 010] node neighbors received: 1, 2, 3, 4, 13 13:24:58.518 CNTRLR [Node 010] Interview stage completed: Neighbors 13:24:58.518 CNTRLR [Node 010] Interview completed 13:24:58.521 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 97 └─[ConfigurationCCGet] 13:24:58.522 SERIAL » 0x010a001306037005062561d4 (12 bytes) 13:24:58.526 SERIAL « [ACK] (0x06) 13:24:58.526 DRIVER ACK received from controller for current transaction 13:24:58.531 SERIAL « 0x0104011301e8 (6 bytes) 13:24:58.531 SERIAL » [ACK] (0x06) 13:24:58.532 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:58.552 SERIAL « 0x010700136100000288 (9 bytes) 13:24:58.553 SERIAL » [ACK] (0x06) 13:24:58.553 DRIVER « [REQ] [SendData] [confirmation] callbackId: 97 transmitStatus: OK 13:24:58.554 DRIVER ACK received from node for current transaction. RTT = 34.12 ms 13:24:58.586 SERIAL « 0x010b0004000605700606010082 (13 bytes) 13:24:58.589 CNTRLR [Node 006] [~] [Configuration] 6: 0 => 0 13:24:58.596 SERIAL » [ACK] (0x06) 13:24:58.597 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x060100 13:24:58.597 DRIVER ACK already received, resolving transaction 13:24:58.597 DRIVER resuming send queue 13:24:58.598 CNTRLR « [Node 006] parameter #6 has value: 0 13:24:58.598 CNTRLR » [Node 006] querying parameter #7 value... 13:24:58.600 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 98 └─[ConfigurationCCGet] 13:24:58.600 SERIAL » 0x010a001306037005072562d6 (12 bytes) 13:24:58.600 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:58.604 SERIAL « [ACK] (0x06) 13:24:58.604 DRIVER ACK received from controller for current transaction 13:24:58.632 SERIAL « 0x0104011301e8 (6 bytes) 13:24:58.633 SERIAL » [ACK] (0x06) 13:24:58.634 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:58.641 SERIAL « 0x01070013620000038a (9 bytes) 13:24:58.642 SERIAL » [ACK] (0x06) 13:24:58.643 DRIVER « [REQ] [SendData] [confirmation] callbackId: 98 transmitStatus: OK 13:24:58.644 DRIVER ACK received from node for current transaction. RTT = 44.38 ms 13:24:58.685 SERIAL « 0x010b0004000605700607010281 (13 bytes) 13:24:58.688 CNTRLR [Node 006] [~] [Configuration] 7: 2 => 2 13:24:58.696 SERIAL » [ACK] (0x06) 13:24:58.697 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x070102 13:24:58.698 DRIVER ACK already received, resolving transaction 13:24:58.698 DRIVER resuming send queue 13:24:58.699 CNTRLR « [Node 006] parameter #7 has value: 2 13:24:58.699 CNTRLR » [Node 006] querying parameter #8 value... 13:24:58.706 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 99 └─[ConfigurationCCGet] 13:24:58.707 SERIAL » 0x010a001306037005082563d8 (12 bytes) 13:24:58.707 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:58.743 SERIAL « [ACK] (0x06) 13:24:58.744 DRIVER ACK received from controller for current transaction 13:24:58.745 SERIAL « 0x0104011301e8 (6 bytes) 13:24:58.746 SERIAL » [ACK] (0x06) 13:24:58.747 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:58.762 SERIAL « 0x01070013630000038b (9 bytes) 13:24:58.763 SERIAL » [ACK] (0x06) 13:24:58.765 DRIVER « [REQ] [SendData] [confirmation] callbackId: 99 transmitStatus: OK 13:24:58.765 DRIVER ACK received from node for current transaction. RTT = 59.10 ms 13:24:58.776 SERIAL « 0x010b000400060570060801008c (13 bytes) 13:24:58.780 CNTRLR [Node 006] [~] [Configuration] 8: 0 => 0 13:24:58.790 SERIAL » [ACK] (0x06) 13:24:58.791 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x080100 13:24:58.792 DRIVER ACK already received, resolving transaction 13:24:58.792 DRIVER resuming send queue 13:24:58.792 CNTRLR « [Node 006] parameter #8 has value: 0 13:24:58.793 CNTRLR [Node 006] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 13:24:58.794 CNTRLR [Node 006] ProtectionCC: doing a partial interview... 13:24:58.795 CNTRLR » [Node 006] querying protection status... 13:24:58.796 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 100 └─[ProtectionCCGet] 13:24:58.797 SERIAL » 0x01090013060275022564d7 (11 bytes) 13:24:58.798 DRIVER workOffSendQueue > skipping because a transaction is pending 13:24:58.809 SERIAL « [ACK] (0x06) 13:24:58.810 DRIVER ACK received from controller for current transaction 13:24:58.813 SERIAL « 0x0104011301e8 (6 bytes) 13:24:58.813 SERIAL » [ACK] (0x06) 13:24:58.815 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:58.859 SERIAL « 0x01070013640000038c (9 bytes) 13:24:58.860 SERIAL » [ACK] (0x06) 13:24:58.861 DRIVER « [REQ] [SendData] [confirmation] callbackId: 100 transmitStatus: OK 13:24:58.862 DRIVER ACK received from node for current transaction. RTT = 65.87 ms 13:24:58.875 SERIAL « 0x0109000400060375030081 (11 bytes) 13:24:58.876 CNTRLR [Node 006] [~] [Protection] local: 0 => 0 [Endpoint 0] 13:24:58.886 SERIAL » [ACK] (0x06) 13:24:58.887 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[ProtectionCCReport] payload: 0x00 13:24:58.887 DRIVER ACK already received, resolving transaction 13:24:58.888 DRIVER resuming send queue 13:24:58.889 CNTRLR « [Node 006] received protection status: local: Unprotected 13:24:58.890 CNTRLR [Node 006] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 13:24:58.894 DRIVER » [Node 011] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 101 └─[NoOperationCC] 13:24:58.895 SERIAL » 0x010800130b01002565ae (10 bytes) 13:24:58.913 SERIAL « [ACK] (0x06) 13:24:58.913 DRIVER ACK received from controller for current transaction 13:24:58.913 SERIAL « 0x0104011301e8 (6 bytes) 13:24:58.914 SERIAL » [ACK] (0x06) 13:24:58.914 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:24:58.920 CNTRLR [Node 006] ThermostatModeCC: doing a partial interview... 13:24:58.921 CNTRLR » [Node 006] querying current thermostat mode... 13:24:58.924 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:06.311 SERIAL « 0x01070013650102e568 (9 bytes) 13:25:06.311 SERIAL » [ACK] (0x06) 13:25:06.312 DRIVER « [REQ] [SendData] [fatal_node] callbackId: 101 transmitStatus: NoAck 13:25:06.314 CNTRLR [Node 011] Node 11 did not respond to the current transaction after 1 attempts , it is presumed dead (Status NoAck) 13:25:06.315 CNTRLR [Node 011] The node is now dead. 13:25:06.318 DRIVER resuming send queue 13:25:06.319 CNTRLR [Node 011] ping failed: Node 11 did not respond to the current transaction aft er 1 attempts, it is presumed dead (Status NoAck) 13:25:06.322 CNTRLR [Node 011] ManufacturerSpecificCC: doing a partial interview... 13:25:06.322 CNTRLR [Node 011] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 13:25:06.324 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 102 └─[ThermostatModeCCGet] 13:25:06.324 SERIAL » 0x01090013060240022566e0 (11 bytes) 13:25:06.325 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:06.336 SERIAL « [ACK] (0x06) 13:25:06.337 DRIVER ACK received from controller for current transaction 13:25:06.337 SERIAL « 0x0104011301e8 (6 bytes) 13:25:06.338 SERIAL » [ACK] (0x06) 13:25:06.339 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:06.340 CNTRLR [Node 011] VersionCC: doing a partial interview... 13:25:06.341 CNTRLR [Node 011] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 13:25:06.341 CNTRLR [Node 011] trying to load device config 13:25:06.356 CNTRLR [Node 011] device config loaded 13:25:06.358 CNTRLR [Node 011] ZWavePlusCC: doing a partial interview... 13:25:06.358 CNTRLR [Node 011] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 13:25:06.359 CNTRLR [Node 011] BinarySwitchCC: doing a partial interview... 13:25:06.359 CNTRLR » [Node 011] querying Binary Switch state... 13:25:06.361 CNTRLR [Node 011] Interview attempt (1/5) failed, node is dead. 13:25:07.645 SERIAL « 0x01070013660000830e (9 bytes) 13:25:07.646 SERIAL » [ACK] (0x06) 13:25:07.646 DRIVER « [REQ] [SendData] [confirmation] callbackId: 102 transmitStatus: OK 13:25:07.646 DRIVER ACK received from node for current transaction. RTT = 1322.84 ms 13:25:07.675 SERIAL « 0x010a000400060440030100b1 (12 bytes) 13:25:07.676 CNTRLR [Node 006] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 0] 13:25:07.683 SERIAL » [ACK] (0x06) 13:25:07.683 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[ThermostatModeCCReport] payload: 0x0100 13:25:07.684 DRIVER ACK already received, resolving transaction 13:25:07.684 DRIVER resuming send queue 13:25:07.685 CNTRLR « [Node 006] received current thermostat mode: Heat 13:25:07.686 CNTRLR [Node 006] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 0] [internal] ue => true 13:25:07.687 DRIVER » [Node 012] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 103 └─[NoOperationCC] 13:25:07.688 SERIAL » 0x010800130c01002567ab (10 bytes) 13:25:07.700 SERIAL « [ACK] (0x06) 13:25:07.701 DRIVER ACK received from controller for current transaction 13:25:07.701 SERIAL « 0x0104011301e8 (6 bytes) 13:25:07.702 SERIAL » [ACK] (0x06) 13:25:07.702 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:07.704 CNTRLR [Node 006] MultilevelSwitchCC: doing a partial interview... 13:25:07.704 CNTRLR » [Node 006] requesting current switch state... 13:25:07.706 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:11.669 SERIAL « 0x010700136700018e03 (9 bytes) 13:25:11.669 SERIAL » [ACK] (0x06) 13:25:11.670 DRIVER « [REQ] [SendData] [final] callbackId: 103 transmitStatus: OK 13:25:11.670 DRIVER ACK already received, resolving transaction 13:25:11.670 DRIVER resuming send queue 13:25:11.671 CNTRLR « [Node 012] ping successful 13:25:11.673 CNTRLR [Node 012] ManufacturerSpecificCC: doing a partial interview... 13:25:11.673 CNTRLR [Node 012] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 13:25:11.675 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 104 └─[MultilevelSwitchCCGet] 13:25:11.675 SERIAL » 0x0109001306022602256888 (11 bytes) 13:25:11.684 SERIAL « [ACK] (0x06) 13:25:11.685 DRIVER ACK received from controller for current transaction 13:25:11.686 SERIAL « 0x0104011301e8 (6 bytes) 13:25:11.687 SERIAL » [ACK] (0x06) 13:25:11.687 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:11.688 CNTRLR [Node 012] VersionCC: doing a partial interview... 13:25:11.689 CNTRLR [Node 012] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 13:25:11.690 CNTRLR [Node 012] trying to load device config 13:25:11.701 CNTRLR [Node 012] device config loaded 13:25:11.702 CNTRLR [Node 012] ZWavePlusCC: doing a partial interview... 13:25:11.702 CNTRLR [Node 012] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 13:25:11.703 CNTRLR [Node 012] BinarySwitchCC: doing a partial interview... 13:25:11.703 CNTRLR » [Node 012] querying Binary Switch state... 13:25:11.704 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:12.980 SERIAL « 0x010700136800008201 (9 bytes) 13:25:12.981 SERIAL » [ACK] (0x06) 13:25:12.981 DRIVER « [REQ] [SendData] [confirmation] callbackId: 104 transmitStatus: OK 13:25:12.982 DRIVER ACK received from node for current transaction. RTT = 1306.91 ms 13:25:13.010 SERIAL « 0x01090004000603260300d2 (11 bytes) 13:25:13.012 CNTRLR [Node 006] [~] [Multilevel Switch] currentValue: 0 => 0 [Endpoint 0] 13:25:13.018 SERIAL » [ACK] (0x06) 13:25:13.019 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[MultilevelSwitchCCReport] current value: 0 13:25:13.019 DRIVER ACK already received, resolving transaction 13:25:13.019 DRIVER resuming send queue 13:25:13.022 CNTRLR [Node 006] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 13:25:13.023 DRIVER » [Node 012] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 105 └─[BinarySwitchCCGet] 13:25:13.024 SERIAL » 0x010900130c022502256980 (11 bytes) 13:25:13.036 SERIAL « [ACK] (0x06) 13:25:13.037 DRIVER ACK received from controller for current transaction 13:25:13.037 SERIAL « 0x0104011301e8 (6 bytes) 13:25:13.037 SERIAL » [ACK] (0x06) 13:25:13.038 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:13.039 CNTRLR [Node 006] AssociationCC: doing a partial interview... 13:25:13.040 CNTRLR » [Node 006] querying association group #1... 13:25:13.041 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:13.065 SERIAL « 0x01090004000c032503ff24 (11 bytes) 13:25:13.066 CNTRLR [Node 012] [~] [Binary Switch] currentValue: true => true [Endpoint 0] 13:25:13.073 SERIAL » [ACK] (0x06) 13:25:13.073 DRIVER « [Node 012] [REQ] [ApplicationCommand] [final] └─[BinarySwitchCCReport] payload: 0xff 13:25:13.073 CNTRLR [Node 012] The node is now awake. 13:25:13.075 CNTRLR [Node 012] The node is ready to be used 13:25:13.076 DRIVER ACK already received, resolving transaction 13:25:13.076 DRIVER resuming send queue 13:25:13.078 CNTRLR « [Node 012] received Binary Switch state: current value: true 13:25:13.079 CNTRLR [Node 012] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 13:25:13.079 CNTRLR [Node 012] MultilevelSwitchCC: doing a partial interview... 13:25:13.080 CNTRLR » [Node 012] requesting current switch state... 13:25:13.081 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 106 └─[AssociationCCGet] groupId: 1 13:25:13.081 SERIAL » 0x010a00130603850201256a2a (12 bytes) 13:25:13.082 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:13.082 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:13.086 SERIAL « [ACK] (0x06) 13:25:13.087 DRIVER ACK received from controller for current transaction 13:25:13.092 SERIAL « 0x0104011301e8 (6 bytes) 13:25:13.092 SERIAL » [ACK] (0x06) 13:25:13.093 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:13.116 SERIAL « 0x010700136a00000382 (9 bytes) 13:25:13.117 SERIAL » [ACK] (0x06) 13:25:13.118 DRIVER « [REQ] [SendData] [confirmation] callbackId: 106 transmitStatus: OK 13:25:13.118 DRIVER ACK received from node for current transaction. RTT = 37.08 ms 13:25:13.136 SERIAL « 0x010700136a00000584 (9 bytes) 13:25:13.137 SERIAL » [ACK] (0x06) 13:25:13.137 DRIVER « [REQ] [SendData] [confirmation] callbackId: 106 transmitStatus: OK 13:25:13.138 DRIVER ACK received from node for current transaction. RTT = 57.02 ms 13:25:13.245 SERIAL « 0x010c000400060685030101000170 (14 bytes) 13:25:13.246 SERIAL » [ACK] (0x06) 13:25:13.247 CNTRLR [Node 006] [~] [Association] maxNodes[1]: 1 => 1 [internal] 13:25:13.247 CNTRLR [Node 006] [~] [Association] nodeIds[1]: 1 => 1 [internal] 13:25:13.248 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[AssociationCCReport] groupId: 1 maxNodes: 1 nodeIds: 1 reportsToFollow: 0 13:25:13.248 DRIVER ACK already received, resolving transaction 13:25:13.248 DRIVER resuming send queue 13:25:13.249 CNTRLR « [Node 006] received information for association group #1: maximum # of nodes: 1 currently assigned nodes: 1 13:25:13.250 CNTRLR [Node 006] [~] [Association] hasLifeline: true => true [internal] 13:25:13.250 CNTRLR [Node 006] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 13:25:13.251 CNTRLR [Node 006] AssociationGroupInfoCC: doing a partial interview... 13:25:13.251 CNTRLR [Node 006] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 13:25:13.252 CNTRLR [Node 006] NotificationCC: doing a partial interview... 13:25:13.252 CNTRLR » [Node 006] querying notification status for Power Management... 13:25:13.257 DRIVER » [Node 012] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 107 └─[MultilevelSwitchCCGet] 13:25:13.257 SERIAL » 0x010900130c022602256b81 (11 bytes) 13:25:13.258 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:13.267 SERIAL « 0x01090004000c032503ff24 (11 bytes) 13:25:13.268 CNTRLR [Node 012] [~] [Binary Switch] currentValue: true => true [Endpoint 0] 13:25:13.275 SERIAL » [ACK] (0x06) 13:25:13.276 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] payload: 0xff 13:25:13.277 SERIAL « [CAN] (0x18) 13:25:13.279 DRIVER CAN received - scheduling transmission attempt (2/3) in 100 ms... 13:25:13.382 DRIVER » [Node 012] [REQ] [SendData] [attempt 2/3] │ transmitOptions: 0x25 │ callbackId: 107 └─[MultilevelSwitchCCGet] 13:25:13.383 SERIAL » 0x010900130c022602256b81 (11 bytes) 13:25:13.387 SERIAL « [ACK] (0x06) 13:25:13.388 DRIVER ACK received from controller for current transaction 13:25:13.408 SERIAL « 0x0104011301e8 (6 bytes) 13:25:13.409 SERIAL » [ACK] (0x06) 13:25:13.409 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:13.414 SERIAL « 0x010700136b00000282 (9 bytes) 13:25:13.416 SERIAL » [ACK] (0x06) 13:25:13.416 DRIVER « [REQ] [SendData] [confirmation] callbackId: 107 transmitStatus: OK 13:25:13.417 DRIVER ACK received from node for current transaction. RTT = 35.62 ms 13:25:13.494 SERIAL « 0x010b0004000c052603ffff00dc (13 bytes) 13:25:13.496 CNTRLR [Node 012] [~] [Multilevel Switch] targetValue: 99 => 99 [Endpoint 0] 13:25:13.504 CNTRLR [Node 012] [~] [Multilevel Switch] duration: [Duration: 0seconds] [Endpoint 0] => [Duration: 0seconds] 13:25:13.511 CNTRLR [Node 012] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 0] 13:25:13.518 SERIAL » [ACK] (0x06) 13:25:13.519 DRIVER « [Node 012] [REQ] [ApplicationCommand] [final] └─[MultilevelSwitchCCReport] current value: 99 target value: 99 duration: [Duration: 0seconds] 13:25:13.520 DRIVER ACK already received, resolving transaction 13:25:13.520 DRIVER resuming send queue 13:25:13.522 CNTRLR [Node 012] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 13:25:13.525 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 108 └─[NotificationCCGet] 13:25:13.526 SERIAL » 0x010c001306057104000800256cd7 (14 bytes) 13:25:13.543 SERIAL « [ACK] (0x06) 13:25:13.543 DRIVER ACK received from controller for current transaction 13:25:13.544 SERIAL « 0x0104011301e8 (6 bytes) 13:25:13.544 SERIAL » [ACK] (0x06) 13:25:13.545 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:13.547 CNTRLR [Node 012] ConfigurationCC: Loading configuration parameters from device confi g 13:25:13.550 CNTRLR [Node 012] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 13:25:13.551 CNTRLR [Node 012] [Configuration] 1: metadata updated 13:25:13.560 CNTRLR [Node 012] [Configuration] 2: metadata updated 13:25:13.569 CNTRLR [Node 012] [Configuration] 3: metadata updated 13:25:13.577 CNTRLR [Node 012] [Configuration] 4: metadata updated 13:25:13.585 CNTRLR [Node 012] [Configuration] 5: metadata updated 13:25:13.593 CNTRLR [Node 012] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 13:25:13.594 CNTRLR » [Node 012] querying parameter #1 value... 13:25:13.596 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:13.604 SERIAL « 0x010700136c00000384 (9 bytes) 13:25:13.605 SERIAL » [ACK] (0x06) 13:25:13.606 DRIVER « [REQ] [SendData] [confirmation] callbackId: 108 transmitStatus: OK 13:25:13.606 DRIVER ACK received from node for current transaction. RTT = 81.45 ms 13:25:13.622 SERIAL « 0x010f00040006097105000000ff08000078 (17 bytes) 13:25:13.623 SERIAL » [ACK] (0x06) 13:25:13.625 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[NotificationCCReport] payload: 0x000000ff080000 13:25:13.625 DRIVER ACK already received, resolving transaction 13:25:13.626 DRIVER resuming send queue 13:25:13.640 CNTRLR » [Node 006] querying notification status for System... 13:25:13.643 DRIVER » [Node 012] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 109 └─[ConfigurationCCGet] 13:25:13.644 SERIAL » 0x010a00130c03700501256dd5 (12 bytes) 13:25:13.645 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:13.673 SERIAL « [ACK] (0x06) 13:25:13.673 DRIVER ACK received from controller for current transaction 13:25:13.673 SERIAL « 0x0104011301e8 (6 bytes) 13:25:13.674 SERIAL » [ACK] (0x06) 13:25:13.674 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:13.681 SERIAL « 0x010700136d00000284 (9 bytes) 13:25:13.682 SERIAL » [ACK] (0x06) 13:25:13.683 DRIVER « [REQ] [SendData] [confirmation] callbackId: 109 transmitStatus: OK 13:25:13.684 DRIVER ACK received from node for current transaction. RTT = 41.16 ms 13:25:13.697 SERIAL « 0x010b0004000c0570060101018e (13 bytes) 13:25:13.700 CNTRLR [Node 012] [~] [Configuration] 1: 1 => 1 13:25:13.708 SERIAL » [ACK] (0x06) 13:25:13.708 DRIVER « [Node 012] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x010101 13:25:13.709 DRIVER ACK already received, resolving transaction 13:25:13.709 DRIVER resuming send queue 13:25:13.709 CNTRLR « [Node 012] parameter #1 has value: 1 13:25:13.710 CNTRLR » [Node 012] querying parameter #2 value... 13:25:13.711 DRIVER » [Node 006] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 110 └─[NotificationCCGet] 13:25:13.712 SERIAL » 0x010c001306057104000900256ed4 (14 bytes) 13:25:13.712 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:13.716 SERIAL « [ACK] (0x06) 13:25:13.716 DRIVER ACK received from controller for current transaction 13:25:13.721 SERIAL « 0x0104011301e8 (6 bytes) 13:25:13.722 SERIAL » [ACK] (0x06) 13:25:13.722 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:13.741 SERIAL « 0x010700136e00000287 (9 bytes) 13:25:13.742 SERIAL » [ACK] (0x06) 13:25:13.742 DRIVER « [REQ] [SendData] [confirmation] callbackId: 110 transmitStatus: OK 13:25:13.743 DRIVER ACK received from node for current transaction. RTT = 31.87 ms 13:25:13.762 SERIAL « 0x010f00040006097105000000ff09000079 (17 bytes) 13:25:13.763 SERIAL » [ACK] (0x06) 13:25:13.764 DRIVER « [Node 006] [REQ] [ApplicationCommand] [final] └─[NotificationCCReport] payload: 0x000000ff090000 13:25:13.765 DRIVER ACK already received, resolving transaction 13:25:13.765 DRIVER resuming send queue 13:25:13.772 CNTRLR [Node 006] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 13:25:13.773 DRIVER » [Node 012] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 111 └─[ConfigurationCCGet] 13:25:13.774 SERIAL » 0x010a00130c03700502256fd4 (12 bytes) 13:25:13.790 SERIAL « [ACK] (0x06) 13:25:13.791 DRIVER ACK received from controller for current transaction 13:25:13.791 SERIAL « 0x0104011301e8 (6 bytes) 13:25:13.792 SERIAL » [ACK] (0x06) 13:25:13.792 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:13.801 CNTRLR [Node 006] Interview stage completed: CommandClasses 13:25:13.801 CNTRLR [Node 006] Interview stage completed: OverwriteConfig 13:25:13.801 CNTRLR » [Node 006] requesting node neighbors... 13:25:13.803 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:13.804 SERIAL « 0x010700136f00000286 (9 bytes) 13:25:13.806 SERIAL » [ACK] (0x06) 13:25:13.807 DRIVER « [REQ] [SendData] [confirmation] callbackId: 111 transmitStatus: OK 13:25:13.807 DRIVER ACK received from node for current transaction. RTT = 34.41 ms 13:25:13.815 SERIAL « 0x010b0004000c0570060201008c (13 bytes) 13:25:13.818 CNTRLR [Node 012] [~] [Configuration] 2: 0 => 0 13:25:13.827 SERIAL » [ACK] (0x06) 13:25:13.828 DRIVER « [Node 012] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x020100 13:25:13.829 DRIVER ACK already received, resolving transaction 13:25:13.829 DRIVER resuming send queue 13:25:13.830 CNTRLR « [Node 012] parameter #2 has value: 0 13:25:13.830 CNTRLR » [Node 012] querying parameter #3 value... 13:25:13.832 DRIVER » [Node 006] [REQ] [GetRoutingInfo] [P: Controller] removeNonRepeaters: false removeBadLinks: false 13:25:13.833 SERIAL » 0x01070080060000007e (9 bytes) 13:25:13.833 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:13.838 SERIAL « [ACK] (0x06) 13:25:13.839 DRIVER ACK received from controller for current transaction 13:25:13.840 SERIAL « 0x012001801b0c00000000000000000000000000000000000000000000000000000 (34 bytes) 049 13:25:13.841 SERIAL » [ACK] (0x06) 13:25:13.842 DRIVER « [RES] [GetRoutingInfo] [final] node ids: 1, 2, 4, 5, 11, 12 13:25:13.843 DRIVER ACK already received, resolving transaction 13:25:13.843 DRIVER resuming send queue 13:25:13.844 CNTRLR « [Node 006] node neighbors received: 1, 2, 4, 5, 11, 12 13:25:13.845 CNTRLR [Node 006] Interview stage completed: Neighbors 13:25:13.845 CNTRLR [Node 006] Interview completed 13:25:13.854 DRIVER » [Node 012] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 112 └─[ConfigurationCCGet] 13:25:13.854 SERIAL » 0x010a00130c037005032570ca (12 bytes) 13:25:13.861 SERIAL « [ACK] (0x06) 13:25:13.862 DRIVER ACK received from controller for current transaction 13:25:13.868 SERIAL « 0x0104011301e8 (6 bytes) 13:25:13.869 SERIAL » [ACK] (0x06) 13:25:13.870 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:13.881 SERIAL « 0x010700137000000299 (9 bytes) 13:25:13.881 SERIAL » [ACK] (0x06) 13:25:13.882 DRIVER « [REQ] [SendData] [confirmation] callbackId: 112 transmitStatus: OK 13:25:13.883 DRIVER ACK received from node for current transaction. RTT = 29.19 ms 13:25:13.896 SERIAL « 0x010b0004000c0570060301018c (13 bytes) 13:25:13.898 CNTRLR [Node 012] [~] [Configuration] 3: 1 => 1 13:25:13.906 SERIAL » [ACK] (0x06) 13:25:13.907 DRIVER « [Node 012] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x030101 13:25:13.907 DRIVER ACK already received, resolving transaction 13:25:13.907 DRIVER resuming send queue 13:25:13.908 CNTRLR « [Node 012] parameter #3 has value: 1 13:25:13.908 CNTRLR » [Node 012] querying parameter #4 value... 13:25:13.909 DRIVER » [Node 012] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 113 └─[ConfigurationCCGet] 13:25:13.910 SERIAL » 0x010a00130c037005042571cc (12 bytes) 13:25:13.910 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:13.914 SERIAL « [ACK] (0x06) 13:25:13.914 DRIVER ACK received from controller for current transaction 13:25:13.919 SERIAL « 0x0104011301e8 (6 bytes) 13:25:13.920 SERIAL » [ACK] (0x06) 13:25:13.920 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:13.938 SERIAL « 0x010700137100000399 (9 bytes) 13:25:13.939 SERIAL » [ACK] (0x06) 13:25:13.940 DRIVER « [REQ] [SendData] [confirmation] callbackId: 113 transmitStatus: OK 13:25:13.941 DRIVER ACK received from node for current transaction. RTT = 31.71 ms 13:25:13.952 SERIAL « 0x010b0004000c0570060401018b (13 bytes) 13:25:13.955 CNTRLR [Node 012] [~] [Configuration] 4: 1 => 1 13:25:13.962 SERIAL » [ACK] (0x06) 13:25:13.963 DRIVER « [Node 012] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x040101 13:25:13.964 DRIVER ACK already received, resolving transaction 13:25:13.964 DRIVER resuming send queue 13:25:13.964 CNTRLR « [Node 012] parameter #4 has value: 1 13:25:13.965 CNTRLR » [Node 012] querying parameter #5 value... 13:25:13.967 DRIVER » [Node 012] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 114 └─[ConfigurationCCGet] 13:25:13.975 SERIAL » 0x010a00130c037005052572ce (12 bytes) 13:25:13.976 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:13.987 SERIAL « [ACK] (0x06) 13:25:13.988 DRIVER ACK received from controller for current transaction 13:25:13.999 SERIAL « 0x0104011301e8 (6 bytes) 13:25:14.000 SERIAL » [ACK] (0x06) 13:25:14.000 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:14.006 SERIAL « 0x01070013720000029b (9 bytes) 13:25:14.007 SERIAL » [ACK] (0x06) 13:25:14.008 DRIVER « [REQ] [SendData] [confirmation] callbackId: 114 transmitStatus: OK 13:25:14.008 DRIVER ACK received from node for current transaction. RTT = 41.97 ms 13:25:14.023 SERIAL « 0x010b0004000c0570060501018a (13 bytes) 13:25:14.025 CNTRLR [Node 012] [~] [Configuration] 5: 1 => 1 13:25:14.032 SERIAL » [ACK] (0x06) 13:25:14.033 DRIVER « [Node 012] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x050101 13:25:14.034 DRIVER ACK already received, resolving transaction 13:25:14.034 DRIVER resuming send queue 13:25:14.034 CNTRLR « [Node 012] parameter #5 has value: 1 13:25:14.035 CNTRLR [Node 012] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 13:25:14.036 CNTRLR [Node 012] AssociationCC: doing a partial interview... 13:25:14.036 CNTRLR [Node 012] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 13:25:14.037 CNTRLR [Node 012] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 13:25:14.038 CNTRLR [Node 012] MultiChannelAssociationCC: doing a partial interview... 13:25:14.038 CNTRLR » [Node 012] querying multi channel association group #1... 13:25:14.040 DRIVER » [Node 012] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 115 └─[MultiChannelAssociationCCGet] group id: 1 13:25:14.040 SERIAL » 0x010a00130c038e0201257332 (12 bytes) 13:25:14.041 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:14.044 SERIAL « [ACK] (0x06) 13:25:14.045 DRIVER ACK received from controller for current transaction 13:25:14.051 SERIAL « 0x0104011301e8 (6 bytes) 13:25:14.051 SERIAL » [ACK] (0x06) 13:25:14.052 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:14.068 SERIAL « 0x01070013730000039b (9 bytes) 13:25:14.069 SERIAL » [ACK] (0x06) 13:25:14.069 DRIVER « [REQ] [SendData] [confirmation] callbackId: 115 transmitStatus: OK 13:25:14.069 DRIVER ACK received from node for current transaction. RTT = 29.99 ms 13:25:14.083 SERIAL « 0x010e0004000c088e0301050000010079 (16 bytes) 13:25:14.084 SERIAL » [ACK] (0x06) 13:25:14.085 CNTRLR [Node 012] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 13:25:14.092 CNTRLR [Node 012] [~] [Multi Channel Association] nodeIds[1]: => 13:25:14.100 CNTRLR [Node 012] [~] [Multi Channel Association] endpoints[1]: [object Object] => [o bject Object] 13:25:14.108 DRIVER « [Node 012] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: endpoints: 1:0 13:25:14.108 DRIVER ACK already received, resolving transaction 13:25:14.109 DRIVER resuming send queue 13:25:14.109 CNTRLR « [Node 012] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 1:0 13:25:14.109 CNTRLR » [Node 012] querying multi channel association group #2... 13:25:14.111 DRIVER » [Node 012] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 116 └─[MultiChannelAssociationCCGet] group id: 2 13:25:14.111 SERIAL » 0x010a00130c038e0202257436 (12 bytes) 13:25:14.112 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:14.115 SERIAL « [ACK] (0x06) 13:25:14.115 DRIVER ACK received from controller for current transaction 13:25:14.135 SERIAL « 0x0104011301e8 (6 bytes) 13:25:14.136 SERIAL » [ACK] (0x06) 13:25:14.136 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:14.147 SERIAL « 0x01070013740000029d (9 bytes) 13:25:14.148 SERIAL » [ACK] (0x06) 13:25:14.149 DRIVER « [REQ] [SendData] [confirmation] callbackId: 116 transmitStatus: OK 13:25:14.149 DRIVER ACK received from node for current transaction. RTT = 38.92 ms 13:25:14.156 SERIAL « 0x010b0004000c058e0302050073 (13 bytes) 13:25:14.157 SERIAL » [ACK] (0x06) 13:25:14.158 CNTRLR [Node 012] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 13:25:14.166 CNTRLR [Node 012] [~] [Multi Channel Association] nodeIds[2]: => 13:25:14.174 CNTRLR [Node 012] [~] [Multi Channel Association] endpoints[2]: => 13:25:14.184 DRIVER « [Node 012] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 13:25:14.184 DRIVER ACK already received, resolving transaction 13:25:14.184 DRIVER resuming send queue 13:25:14.185 CNTRLR « [Node 012] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 13:25:14.186 CNTRLR [Node 012] [~] [Association] hasLifeline: true => true [internal] 13:25:14.186 CNTRLR [Node 012] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 13:25:14.188 DRIVER » [Node 013] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 117 └─[NoOperationCC] 13:25:14.188 SERIAL » 0x010800130d01002575b8 (10 bytes) 13:25:14.204 SERIAL « [ACK] (0x06) 13:25:14.205 DRIVER ACK received from controller for current transaction 13:25:14.205 SERIAL « 0x0104011301e8 (6 bytes) 13:25:14.206 SERIAL » [ACK] (0x06) 13:25:14.206 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:14.220 CNTRLR [Node 012] AssociationGroupInfoCC: doing a partial interview... 13:25:14.222 CNTRLR [Node 012] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 13:25:14.223 CNTRLR [Node 012] Interview stage completed: CommandClasses 13:25:14.223 CNTRLR [Node 012] Interview stage completed: OverwriteConfig 13:25:14.224 CNTRLR » [Node 012] requesting node neighbors... 13:25:14.227 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:14.228 SERIAL « 0x01070013750000029c (9 bytes) 13:25:14.229 SERIAL » [ACK] (0x06) 13:25:14.229 DRIVER « [REQ] [SendData] [final] callbackId: 117 transmitStatus: OK 13:25:14.230 DRIVER ACK already received, resolving transaction 13:25:14.230 DRIVER resuming send queue 13:25:14.231 CNTRLR « [Node 013] ping successful 13:25:14.234 CNTRLR [Node 013] ManufacturerSpecificCC: doing a partial interview... 13:25:14.235 CNTRLR [Node 013] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 13:25:14.235 CNTRLR [Node 013] VersionCC: doing a partial interview... 13:25:14.236 CNTRLR [Node 013] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 13:25:14.237 CNTRLR [Node 013] trying to load device config 13:25:14.244 DRIVER » [Node 012] [REQ] [GetRoutingInfo] [P: Controller] removeNonRepeaters: false removeBadLinks: false 13:25:14.245 SERIAL » 0x010700800c00000074 (9 bytes) 13:25:14.251 SERIAL « [ACK] (0x06) 13:25:14.252 DRIVER ACK received from controller for current transaction 13:25:14.262 CNTRLR [Node 013] device config loaded 13:25:14.264 CNTRLR [Node 013] ZWavePlusCC: doing a partial interview... 13:25:14.265 CNTRLR [Node 013] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 13:25:14.266 CNTRLR [Node 013] BinarySwitchCC: doing a partial interview... 13:25:14.266 CNTRLR » [Node 013] querying Binary Switch state... 13:25:14.268 SERIAL « 0x012001803e0400000000000000000000000000000000000000000000000000000 (34 bytes) 064 13:25:14.269 SERIAL » [ACK] (0x06) 13:25:14.269 DRIVER « [RES] [GetRoutingInfo] [final] node ids: 2, 3, 4, 5, 6, 11 13:25:14.269 DRIVER ACK already received, resolving transaction 13:25:14.270 DRIVER resuming send queue 13:25:14.270 CNTRLR « [Node 012] node neighbors received: 2, 3, 4, 5, 6, 11 13:25:14.270 CNTRLR [Node 012] Interview stage completed: Neighbors 13:25:14.271 CNTRLR [Node 012] Interview completed 13:25:14.273 DRIVER » [Node 013] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 118 └─[BinarySwitchCCGet] 13:25:14.274 SERIAL » 0x010900130d02250225769e (11 bytes) 13:25:14.275 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:14.280 SERIAL « [ACK] (0x06) 13:25:14.281 DRIVER ACK received from controller for current transaction 13:25:14.285 SERIAL « 0x0104011301e8 (6 bytes) 13:25:14.286 SERIAL » [ACK] (0x06) 13:25:14.286 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:14.301 SERIAL « 0x01070013760000029f (9 bytes) 13:25:14.302 SERIAL » [ACK] (0x06) 13:25:14.303 DRIVER « [REQ] [SendData] [confirmation] callbackId: 118 transmitStatus: OK 13:25:14.303 DRIVER ACK received from node for current transaction. RTT = 30.18 ms 13:25:14.317 SERIAL « 0x01090004000d032503ff25 (11 bytes) 13:25:14.319 CNTRLR [Node 013] [~] [Binary Switch] currentValue: true => true [Endpoint 0] 13:25:14.326 SERIAL » [ACK] (0x06) 13:25:14.326 DRIVER « [Node 013] [REQ] [ApplicationCommand] [final] └─[BinarySwitchCCReport] payload: 0xff 13:25:14.329 CNTRLR [Node 013] The node is now awake. 13:25:14.330 CNTRLR [Node 013] The node is ready to be used 13:25:14.332 DRIVER ACK already received, resolving transaction 13:25:14.332 DRIVER resuming send queue 13:25:14.334 CNTRLR « [Node 013] received Binary Switch state: current value: true 13:25:14.335 CNTRLR [Node 013] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 13:25:14.335 CNTRLR [Node 013] MultilevelSwitchCC: doing a partial interview... 13:25:14.335 CNTRLR » [Node 013] requesting current switch state... 13:25:14.337 DRIVER » [Node 013] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 119 └─[MultilevelSwitchCCGet] 13:25:14.338 SERIAL » 0x010900130d02260225779c (11 bytes) 13:25:14.338 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:14.338 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:14.344 SERIAL « [ACK] (0x06) 13:25:14.345 DRIVER ACK received from controller for current transaction 13:25:14.350 SERIAL « 0x0104011301e8 (6 bytes) 13:25:14.351 SERIAL » [ACK] (0x06) 13:25:14.352 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:14.366 SERIAL « 0x01070013770000029e (9 bytes) 13:25:14.367 SERIAL » [ACK] (0x06) 13:25:14.368 DRIVER « [REQ] [SendData] [confirmation] callbackId: 119 transmitStatus: OK 13:25:14.368 DRIVER ACK received from node for current transaction. RTT = 31.26 ms 13:25:14.459 SERIAL « 0x010b0004000d052603ffff00dd (13 bytes) 13:25:14.460 CNTRLR [Node 013] [~] [Multilevel Switch] targetValue: 99 => 99 [Endpoint 0] 13:25:14.470 CNTRLR [Node 013] [~] [Multilevel Switch] duration: [Duration: 0seconds] [Endpoint 0] => [Duration: 0seconds] 13:25:14.476 CNTRLR [Node 013] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 0] 13:25:14.483 SERIAL » [ACK] (0x06) 13:25:14.484 DRIVER « [Node 013] [REQ] [ApplicationCommand] [final] └─[MultilevelSwitchCCReport] current value: 99 target value: 99 duration: [Duration: 0seconds] 13:25:14.484 DRIVER ACK already received, resolving transaction 13:25:14.484 DRIVER resuming send queue 13:25:14.488 CNTRLR [Node 013] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 13:25:14.490 DRIVER » [Node 007] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 120 └─[NoOperationCC] 13:25:14.490 SERIAL » 0x010800130701002578bf (10 bytes) 13:25:14.516 SERIAL « [ACK] (0x06) 13:25:14.517 DRIVER ACK received from controller for current transaction 13:25:14.517 SERIAL « 0x0104011301e8 (6 bytes) 13:25:14.518 SERIAL » [ACK] (0x06) 13:25:14.518 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:14.523 CNTRLR [Node 013] ConfigurationCC: Loading configuration parameters from device confi g 13:25:14.526 CNTRLR [Node 013] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 13:25:14.527 CNTRLR [Node 013] [Configuration] 1: metadata updated 13:25:14.535 CNTRLR [Node 013] [Configuration] 2: metadata updated 13:25:14.543 CNTRLR [Node 013] [Configuration] 3: metadata updated 13:25:14.552 CNTRLR [Node 013] [Configuration] 4: metadata updated 13:25:14.563 CNTRLR [Node 013] [Configuration] 5: metadata updated 13:25:14.571 CNTRLR [Node 013] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 13:25:14.572 CNTRLR » [Node 013] querying parameter #1 value... 13:25:14.574 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:18.592 SERIAL « 0x01070013780101990a (9 bytes) 13:25:18.593 SERIAL » [ACK] (0x06) 13:25:18.594 DRIVER « [REQ] [SendData] [fatal_node] callbackId: 120 transmitStatus: NoAck 13:25:18.595 CNTRLR [Node 007] The node did not respond to the current transaction after 1 attempt s. It is probably asleep, moving its messages to the wakeup queue. 13:25:18.596 CNTRLR [Node 007] The node is now asleep. 13:25:18.598 CNTRLR [Node 007] ping failed: The node is asleep 13:25:18.600 CNTRLR » [Node 007] querying node info... 13:25:18.604 DRIVER » [Node 013] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 121 └─[ConfigurationCCGet] 13:25:18.604 SERIAL » 0x010a00130d037005012579c0 (12 bytes) 13:25:18.605 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:18.626 SERIAL « [ACK] (0x06) 13:25:18.627 DRIVER ACK received from controller for current transaction 13:25:18.632 SERIAL « 0x0104011301e8 (6 bytes) 13:25:18.632 SERIAL » [ACK] (0x06) 13:25:18.633 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:18.649 SERIAL « 0x010700137900000290 (9 bytes) 13:25:18.651 SERIAL » [ACK] (0x06) 13:25:18.652 DRIVER « [REQ] [SendData] [confirmation] callbackId: 121 transmitStatus: OK 13:25:18.653 DRIVER ACK received from node for current transaction. RTT = 49.33 ms 13:25:18.665 SERIAL « 0x010b0004000d0570060101018f (13 bytes) 13:25:18.667 CNTRLR [Node 013] [~] [Configuration] 1: 1 => 1 13:25:18.675 SERIAL » [ACK] (0x06) 13:25:18.676 DRIVER « [Node 013] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x010101 13:25:18.676 DRIVER ACK already received, resolving transaction 13:25:18.676 DRIVER resuming send queue 13:25:18.676 CNTRLR « [Node 013] parameter #1 has value: 1 13:25:18.677 CNTRLR » [Node 013] querying parameter #2 value... 13:25:18.678 DRIVER » [Node 013] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 122 └─[ConfigurationCCGet] 13:25:18.679 SERIAL » 0x010a00130d03700502257ac0 (12 bytes) 13:25:18.679 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:18.700 SERIAL « [ACK] (0x06) 13:25:18.700 DRIVER ACK received from controller for current transaction 13:25:18.706 SERIAL « 0x0104011301e8 (6 bytes) 13:25:18.707 SERIAL » [ACK] (0x06) 13:25:18.707 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:18.722 SERIAL « 0x010700137a00000293 (9 bytes) 13:25:18.723 SERIAL » [ACK] (0x06) 13:25:18.724 DRIVER « [REQ] [SendData] [confirmation] callbackId: 122 transmitStatus: OK 13:25:18.724 DRIVER ACK received from node for current transaction. RTT = 46.00 ms 13:25:18.738 SERIAL « 0x010b0004000d0570060201008d (13 bytes) 13:25:18.744 CNTRLR [Node 013] [~] [Configuration] 2: 0 => 0 13:25:18.752 SERIAL » [ACK] (0x06) 13:25:18.753 DRIVER « [Node 013] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x020100 13:25:18.753 DRIVER ACK already received, resolving transaction 13:25:18.753 DRIVER resuming send queue 13:25:18.754 CNTRLR « [Node 013] parameter #2 has value: 0 13:25:18.754 CNTRLR » [Node 013] querying parameter #3 value... 13:25:18.756 DRIVER » [Node 013] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 123 └─[ConfigurationCCGet] 13:25:18.756 SERIAL » 0x010a00130d03700503257bc0 (12 bytes) 13:25:18.757 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:18.759 SERIAL « [ACK] (0x06) 13:25:18.760 DRIVER ACK received from controller for current transaction 13:25:18.766 SERIAL « 0x0104011301e8 (6 bytes) 13:25:18.768 SERIAL » [ACK] (0x06) 13:25:18.769 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:18.782 SERIAL « 0x010700137b00000292 (9 bytes) 13:25:18.783 SERIAL » [ACK] (0x06) 13:25:18.784 DRIVER « [REQ] [SendData] [confirmation] callbackId: 123 transmitStatus: OK 13:25:18.784 DRIVER ACK received from node for current transaction. RTT = 28.96 ms 13:25:18.798 SERIAL « 0x010b0004000d0570060301018d (13 bytes) 13:25:18.800 CNTRLR [Node 013] [~] [Configuration] 3: 1 => 1 13:25:18.808 SERIAL » [ACK] (0x06) 13:25:18.809 DRIVER « [Node 013] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x030101 13:25:18.809 DRIVER ACK already received, resolving transaction 13:25:18.809 DRIVER resuming send queue 13:25:18.809 CNTRLR « [Node 013] parameter #3 has value: 1 13:25:18.810 CNTRLR » [Node 013] querying parameter #4 value... 13:25:18.812 DRIVER » [Node 013] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 124 └─[ConfigurationCCGet] 13:25:18.812 SERIAL » 0x010a00130d03700504257cc0 (12 bytes) 13:25:18.813 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:18.819 SERIAL « [ACK] (0x06) 13:25:18.820 DRIVER ACK received from controller for current transaction 13:25:18.826 SERIAL « 0x0104011301e8 (6 bytes) 13:25:18.826 SERIAL » [ACK] (0x06) 13:25:18.827 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:18.841 SERIAL « 0x010700137c00000295 (9 bytes) 13:25:18.842 SERIAL » [ACK] (0x06) 13:25:18.843 DRIVER « [REQ] [SendData] [confirmation] callbackId: 124 transmitStatus: OK 13:25:18.844 DRIVER ACK received from node for current transaction. RTT = 32.16 ms 13:25:18.857 SERIAL « 0x010b0004000d0570060401018a (13 bytes) 13:25:18.860 CNTRLR [Node 013] [~] [Configuration] 4: 1 => 1 13:25:18.868 SERIAL » [ACK] (0x06) 13:25:18.869 DRIVER « [Node 013] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x040101 13:25:18.870 DRIVER ACK already received, resolving transaction 13:25:18.870 DRIVER resuming send queue 13:25:18.871 CNTRLR « [Node 013] parameter #4 has value: 1 13:25:18.872 CNTRLR » [Node 013] querying parameter #5 value... 13:25:18.874 DRIVER » [Node 013] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 125 └─[ConfigurationCCGet] 13:25:18.875 SERIAL » 0x010a00130d03700505257dc0 (12 bytes) 13:25:18.875 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:18.879 SERIAL « [ACK] (0x06) 13:25:18.880 DRIVER ACK received from controller for current transaction 13:25:18.885 SERIAL « 0x0104011301e8 (6 bytes) 13:25:18.886 SERIAL » [ACK] (0x06) 13:25:18.886 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:18.901 SERIAL « 0x010700137d00000294 (9 bytes) 13:25:18.902 SERIAL » [ACK] (0x06) 13:25:18.902 DRIVER « [REQ] [SendData] [confirmation] callbackId: 125 transmitStatus: OK 13:25:18.903 DRIVER ACK received from node for current transaction. RTT = 28.95 ms 13:25:18.918 SERIAL « 0x010b0004000d0570060501018b (13 bytes) 13:25:18.920 CNTRLR [Node 013] [~] [Configuration] 5: 1 => 1 13:25:18.928 SERIAL » [ACK] (0x06) 13:25:18.928 DRIVER « [Node 013] [REQ] [ApplicationCommand] [final] └─[ConfigurationCCReport] payload: 0x050101 13:25:18.928 DRIVER ACK already received, resolving transaction 13:25:18.929 DRIVER resuming send queue 13:25:18.929 CNTRLR « [Node 013] parameter #5 has value: 1 13:25:18.930 CNTRLR [Node 013] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 13:25:18.931 DRIVER » [Node 008] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 126 └─[NoOperationCC] 13:25:18.932 SERIAL » 0x01080013080100257eb6 (10 bytes) 13:25:18.941 SERIAL « [ACK] (0x06) 13:25:18.941 DRIVER ACK received from controller for current transaction 13:25:18.944 SERIAL « 0x0104011301e8 (6 bytes) 13:25:18.945 SERIAL » [ACK] (0x06) 13:25:18.945 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:18.950 CNTRLR [Node 013] AssociationCC: doing a partial interview... 13:25:18.951 CNTRLR [Node 013] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 13:25:18.951 CNTRLR [Node 013] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 13:25:18.952 CNTRLR [Node 013] MultiChannelAssociationCC: doing a partial interview... 13:25:18.954 CNTRLR » [Node 013] querying multi channel association group #1... 13:25:18.955 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:23.012 SERIAL « 0x010700137e01019702 (9 bytes) 13:25:23.013 SERIAL » [ACK] (0x06) 13:25:23.013 DRIVER « [REQ] [SendData] [fatal_node] callbackId: 126 transmitStatus: NoAck 13:25:23.013 CNTRLR [Node 008] The node did not respond to the current transaction after 1 attempt s. It is probably asleep, moving its messages to the wakeup queue. 13:25:23.014 CNTRLR [Node 008] The node is now asleep. 13:25:23.016 CNTRLR [Node 008] ping failed: The node is asleep 13:25:23.016 CNTRLR » [Node 008] querying node info... 13:25:23.018 DRIVER » [Node 013] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 127 └─[MultiChannelAssociationCCGet] group id: 1 13:25:23.018 SERIAL » 0x010a00130d038e0201257f3f (12 bytes) 13:25:23.019 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:23.022 SERIAL « [ACK] (0x06) 13:25:23.024 DRIVER ACK received from controller for current transaction 13:25:23.048 SERIAL « 0x0104011301e8 (6 bytes) 13:25:23.049 SERIAL » [ACK] (0x06) 13:25:23.049 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:23.051 SERIAL « 0x010700137f00000296 (9 bytes) 13:25:23.052 SERIAL » [ACK] (0x06) 13:25:23.053 DRIVER « [REQ] [SendData] [confirmation] callbackId: 127 transmitStatus: OK 13:25:23.053 DRIVER ACK received from node for current transaction. RTT = 35.21 ms 13:25:23.063 SERIAL « 0x010e0004000d088e0301050000010078 (16 bytes) 13:25:23.064 SERIAL » [ACK] (0x06) 13:25:23.066 CNTRLR [Node 013] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 13:25:23.077 CNTRLR [Node 013] [~] [Multi Channel Association] nodeIds[1]: => 13:25:23.088 CNTRLR [Node 013] [~] [Multi Channel Association] endpoints[1]: [object Object] => [o bject Object] 13:25:23.097 DRIVER « [Node 013] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: endpoints: 1:0 13:25:23.097 DRIVER ACK already received, resolving transaction 13:25:23.097 DRIVER resuming send queue 13:25:23.098 CNTRLR « [Node 013] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 1:0 13:25:23.098 CNTRLR » [Node 013] querying multi channel association group #2... 13:25:23.102 DRIVER » [Node 013] [REQ] [SendData] [P: Normal] │ transmitOptions: 0x25 │ callbackId: 128 └─[MultiChannelAssociationCCGet] group id: 2 13:25:23.103 SERIAL » 0x010a00130d038e02022580c3 (12 bytes) 13:25:23.103 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:23.109 SERIAL « [ACK] (0x06) 13:25:23.110 DRIVER ACK received from controller for current transaction 13:25:23.117 SERIAL « 0x0104011301e8 (6 bytes) 13:25:23.118 SERIAL » [ACK] (0x06) 13:25:23.119 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:23.130 SERIAL « 0x010700138000000269 (9 bytes) 13:25:23.131 SERIAL » [ACK] (0x06) 13:25:23.132 DRIVER « [REQ] [SendData] [confirmation] callbackId: 128 transmitStatus: OK 13:25:23.132 DRIVER ACK received from node for current transaction. RTT = 30.42 ms 13:25:23.145 SERIAL « 0x010b0004000d058e0302050072 (13 bytes) 13:25:23.145 SERIAL » [ACK] (0x06) 13:25:23.146 CNTRLR [Node 013] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 13:25:23.153 CNTRLR [Node 013] [~] [Multi Channel Association] nodeIds[2]: => 13:25:23.161 CNTRLR [Node 013] [~] [Multi Channel Association] endpoints[2]: => 13:25:23.168 DRIVER « [Node 013] [REQ] [ApplicationCommand] [final] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 13:25:23.169 DRIVER ACK already received, resolving transaction 13:25:23.169 DRIVER resuming send queue 13:25:23.170 CNTRLR « [Node 013] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 13:25:23.170 CNTRLR [Node 013] [~] [Association] hasLifeline: true => true [internal] 13:25:23.171 CNTRLR [Node 013] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 13:25:23.172 DRIVER » [Node 009] [REQ] [SendData] [P: NodeQuery] │ transmitOptions: 0x25 │ callbackId: 129 └─[NoOperationCC] 13:25:23.173 SERIAL » 0x01080013090100258148 (10 bytes) 13:25:23.191 SERIAL « [ACK] (0x06) 13:25:23.191 DRIVER ACK received from controller for current transaction 13:25:23.192 SERIAL « 0x0104011301e8 (6 bytes) 13:25:23.192 SERIAL » [ACK] (0x06) 13:25:23.193 DRIVER « [RES] [SendData] [confirmation] wasSent: true 13:25:23.195 CNTRLR [Node 013] AssociationGroupInfoCC: doing a partial interview... 13:25:23.196 CNTRLR [Node 013] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 13:25:23.197 CNTRLR [Node 013] Interview stage completed: CommandClasses 13:25:23.198 CNTRLR [Node 013] Interview stage completed: OverwriteConfig 13:25:23.198 CNTRLR » [Node 013] requesting node neighbors... 13:25:23.200 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:27.342 SERIAL « 0x01070013810101a0ca (9 bytes) 13:25:27.343 SERIAL » [ACK] (0x06) 13:25:27.343 DRIVER « [REQ] [SendData] [fatal_node] callbackId: 129 transmitStatus: NoAck 13:25:27.344 CNTRLR [Node 009] The node did not respond to the current transaction after 1 attempt s. It is probably asleep, moving its messages to the wakeup queue. 13:25:27.344 CNTRLR [Node 009] The node is now asleep. 13:25:27.346 CNTRLR [Node 009] ping failed: The node is asleep 13:25:27.346 CNTRLR » [Node 009] querying node info... 13:25:27.347 DRIVER » [Node 013] [REQ] [GetRoutingInfo] [P: Controller] removeNonRepeaters: false removeBadLinks: false 13:25:27.348 SERIAL » 0x010700800d00000075 (9 bytes) 13:25:27.348 DRIVER workOffSendQueue > skipping because a transaction is pending 13:25:27.351 SERIAL « [ACK] (0x06) 13:25:27.352 DRIVER ACK received from controller for current transaction 13:25:27.353 SERIAL « 0x012001801f0200000000000000000000000000000000000000000000000000000 (34 bytes) 043 13:25:27.354 SERIAL » [ACK] (0x06) 13:25:27.354 DRIVER « [RES] [GetRoutingInfo] [final] node ids: 1, 2, 3, 4, 5, 10 13:25:27.355 DRIVER ACK already received, resolving transaction 13:25:27.355 DRIVER resuming send queue 13:25:27.355 CNTRLR « [Node 013] node neighbors received: 1, 2, 3, 4, 5, 10 13:25:27.356 CNTRLR [Node 013] Interview stage completed: Neighbors 13:25:27.357 DRIVER The remaining 3 messages are for sleeping nodes, not sending anything! 13:25:27.358 DRIVER Send queue: (3 messages) · [REQ] RequestNodeInfo [Node 7, asleep] · [REQ] RequestNodeInfo [Node 8, asleep] · [REQ] RequestNodeInfo [Node 9, asleep] 13:25:28.552 CNTRLR [Node 013] Interview completed 13:42:01.019 DRIVER destroying driver instance...