10:57:41.966 DRIVER ███████╗ ██╗ ██╗ █████╗ ██╗ ██╗ ███████╗ ██╗ ███████╗ ╚══███╔╝ ██║ ██║ ██╔══██╗ ██║ ██║ ██╔════╝ ██║ ██╔════╝ ███╔╝ ██║ █╗ ██║ ███████║ ██║ ██║ █████╗ █████╗ ██║ ███████╗ ███╔╝ ██║███╗██║ ██╔══██║ ╚██╗ ██╔╝ ██╔══╝ ╚════╝ ██ ██║ ╚════██║ ███████╗ ╚███╔███╔╝ ██║ ██║ ╚████╔╝ ███████╗ ╚█████╔╝ ███████║ ╚══════╝ ╚══╝╚══╝ ╚═╝ ╚═╝ ╚═══╝ ╚══════╝ ╚════╝ ╚══════╝ 10:57:41.970 DRIVER version 5.3.1 10:57:41.971 DRIVER 10:57:41.971 DRIVER starting driver... 10:57:42.005 DRIVER opening serial port /dev/ttyACM0 10:57:42.076 DRIVER serial port opened 10:57:42.079 SERIAL » [NAK] (0x15) 10:57:43.586 DRIVER loading configuration... 10:57:44.117 DRIVER beginning interview... 10:57:44.118 DRIVER added request handler for AddNodeToNetwork (0x4a)... 1 registered 10:57:44.119 DRIVER added request handler for RemoveNodeFromNetwork (0x4b)... 1 registered 10:57:44.121 CNTRLR beginning interview... 10:57:44.122 CNTRLR querying version info... 10:57:44.347 SERIAL » 0x01030015e9 (5 bytes) 10:57:44.349 DRIVER » [REQ] [GetControllerVersion] 10:57:44.353 SERIAL « [ACK] (0x06) 10:57:44.357 SERIAL « 0x011001155a2d5761766520332e3939000195 (18 bytes) 10:57:44.358 SERIAL » [ACK] (0x06) 10:57:44.361 DRIVER « [RES] [GetControllerVersion] payload: 0x5a2d5761766520332e39390001 10:57:44.370 CNTRLR received version info: controller type: Static Controller library version: Z-Wave 3.99 10:57:44.371 CNTRLR querying controller IDs... 10:57:44.378 SERIAL » 0x01030020dc (5 bytes) 10:57:44.379 DRIVER » [REQ] [GetControllerId] 10:57:44.381 SERIAL « [ACK] (0x06) 10:57:44.384 SERIAL « 0x01080120dd454af501f0 (10 bytes) 10:57:44.385 SERIAL » [ACK] (0x06) 10:57:44.387 DRIVER « [RES] [GetControllerId] payload: 0xdd454af501 10:57:44.392 CNTRLR received controller IDs: home ID: 0xdd454af5 own node ID: 1 10:57:44.392 CNTRLR querying controller capabilities... 10:57:44.400 SERIAL » 0x01030005f9 (5 bytes) 10:57:44.400 DRIVER » [REQ] [GetControllerCapabilities] 10:57:44.403 SERIAL « [ACK] (0x06) 10:57:44.405 SERIAL « 0x010401051ce3 (6 bytes) 10:57:44.405 SERIAL » [ACK] (0x06) 10:57:44.407 DRIVER « [RES] [GetControllerCapabilities] payload: 0x1c 10:57:44.412 CNTRLR received controller capabilities: controller role: primary is in other network: false is SIS present: true was real primary: true is a SUC: true 10:57:44.413 CNTRLR querying API capabilities... 10:57:44.420 SERIAL » 0x01030007fb (5 bytes) 10:57:44.420 DRIVER » [REQ] [GetSerialApiCapabilities] 10:57:44.423 SERIAL « [ACK] (0x06) 10:57:44.425 SERIAL « 0x012b01070502011504000001fe83ff88cf1f0000fb9f7da067008080008086000 (45 bytes) 000e87300000e0000401a0009 10:57:44.427 SERIAL » [ACK] (0x06) 10:57:44.428 DRIVER « [RES] [GetSerialApiCapabilities] payload: 0x0502011504000001fe83ff88cf1f0000fb9f7da067008080008086000000e8730 0000e0000401a00 10:57:44.434 CNTRLR received API capabilities: serial API version: 5.2 manufacturer ID: 0x0115 product type: 0x0400 product ID: 0x01 supported functions: · GetSerialApiInitData (0x02) · FUNC_ID_SERIAL_API_APPL_NODE_INFORMATION (0x03) · ApplicationCommand (0x04) · GetControllerCapabilities (0x05) · SetSerialApiTimeouts (0x06) · GetSerialApiCapabilities (0x07) · FUNC_ID_SERIAL_API_SOFT_RESET (0x08) · UNKNOWN_FUNC_UNKNOWN_0x09 (0x09) · UNKNOWN_FUNC_UNKNOWN_0x0a (0x0a) · UNKNOWN_FUNC_RF_RECEIVE_MODE (0x10) · UNKNOWN_FUNC_SET_SLEEP_MODE (0x11) · FUNC_ID_ZW_SEND_NODE_INFORMATION (0x12) · SendData (0x13) · SendDataMulticast (0x14) · GetControllerVersion (0x15) · SendDataAbort (0x16) · FUNC_ID_ZW_R_F_POWER_LEVEL_SET (0x17) · UNKNOWN_FUNC_SEND_DATA_META (0x18) · FUNC_ID_ZW_GET_RANDOM (0x1c) · GetControllerId (0x20) · UNKNOWN_FUNC_MEMORY_GET_BYTE (0x21) · UNKNOWN_FUNC_MEMORY_PUT_BYTE (0x22) · UNKNOWN_FUNC_MEMORY_GET_BUFFER (0x23) · UNKNOWN_FUNC_MEMORY_PUT_BUFFER (0x24) · UNKNOWN_FUNC_FlashAutoProgSet (0x27) · UNKNOWN_FUNC_UNKNOWN_0x28 (0x28) · UNKNOWN_FUNC_NVMGetId (0x29) · UNKNOWN_FUNC_NVMExtReadLongBuffer (0x2a) · UNKNOWN_FUNC_NVMExtWriteLongBuffer (0x2b) · UNKNOWN_FUNC_NVMExtReadLongByte (0x2c) · UNKNOWN_FUNC_NVMExtWriteLongByte (0x2d) · GetNodeProtocolInfo (0x41) · HardReset (0x42) · FUNC_ID_ZW_REPLICATION_COMMAND_COMPLETE (0x44) · FUNC_ID_ZW_REPLICATION_SEND_DATA (0x45) · AssignReturnRoute (0x46) · DeleteReturnRoute (0x47) · RequestNodeNeighborUpdate (0x48) · ApplicationUpdateRequest (0x49) · AddNodeToNetwork (0x4a) · RemoveNodeFromNetwork (0x4b) · FUNC_ID_ZW_CREATE_NEW_PRIMARY (0x4c) · FUNC_ID_ZW_CONTROLLER_CHANGE (0x4d) · FUNC_ID_ZW_SET_LEARN_MODE (0x50) · FUNC_ID_ZW_ASSIGN_SUC_RETURN_ROUTE (0x51) · FUNC_ID_ZW_REQUEST_NETWORK_UPDATE (0x53) · FUNC_ID_ZW_SET_SUC_NODE_ID (0x54) · FUNC_ID_ZW_DELETE_SUC_RETURN_ROUTE (0x55) · GetSUCNodeId (0x56) · UNKNOWN_FUNC_SEND_SUC_ID (0x57) · FUNC_ID_ZW_EXPLORE_REQUEST_INCLUSION (0x5e) · RequestNodeInfo (0x60) · RemoveFailedNode (0x61) · IsFailedNode (0x62) · FUNC_ID_ZW_REPLACE_FAILED_NODE (0x63) · UNKNOWN_FUNC_UNKNOWN_0x66 (0x66) · UNKNOWN_FUNC_UNKNOWN_0x67 (0x67) · UNKNOWN_FUNC_UNKNOWN_0x78 (0x78) · GetRoutingInfo (0x80) · UNKNOWN_FUNC_LOCK_ROUTE_RESPONSE (0x90) · UNKNOWN_FUNC_GET_PRIORITY_ROUTE (0x92) · UNKNOWN_FUNC_SET_PRIORITY_ROUTE (0x93) · UNKNOWN_FUNC_UNKNOWN_0x98 (0x98) · UNKNOWN_FUNC_UNKNOWN_0xB4 (0xb4) · UNKNOWN_FUNC_WATCH_DOG_ENABLE (0xb6) · UNKNOWN_FUNC_WATCH_DOG_DISABLE (0xb7) · UNKNOWN_FUNC_WATCH_DOG_KICK (0xb8) · UNKNOWN_FUNC_UNKNOWN_0xB9 (0xb9) · UNKNOWN_FUNC_RF_POWERLEVEL_GET (0xba) · UNKNOWN_FUNC_GET_LIBRARY_TYPE (0xbd) · UNKNOWN_FUNC_SEND_TEST_FRAME (0xbe) · UNKNOWN_FUNC_GET_PROTOCOL_STATUS (0xbf) · UNKNOWN_FUNC_UNKNOWN_0xD2 (0xd2) · UNKNOWN_FUNC_UNKNOWN_0xD3 (0xd3) · UNKNOWN_FUNC_UNKNOWN_0xD4 (0xd4) · UNKNOWN_FUNC_UNKNOWN_0xEF (0xef) · UNKNOWN_FUNC_ZMEFreqChange (0xf2) · UNKNOWN_FUNC_ZMEBootloaderFlash (0xf4) · UNKNOWN_FUNC_ZMECapabilities (0xf5) 10:57:44.434 CNTRLR finding SUC... 10:57:44.441 SERIAL » 0x01030056aa (5 bytes) 10:57:44.442 DRIVER » [REQ] [GetSUCNodeId] 10:57:44.444 SERIAL « [ACK] (0x06) 10:57:44.446 SERIAL « 0x0104015601ad (6 bytes) 10:57:44.447 SERIAL » [ACK] (0x06) 10:57:44.448 DRIVER « [RES] [GetSUCNodeId] payload: 0x01 10:57:44.453 CNTRLR SUC has node ID 1 10:57:44.685 CNTRLR querying node information... 10:57:44.698 SERIAL » 0x01030002fe (5 bytes) 10:57:44.698 DRIVER » [REQ] [GetSerialApiInitData] 10:57:44.700 SERIAL « [ACK] (0x06) 10:57:44.793 SERIAL « 0x0125010205081d05e4dfe07f00a00000000000000000000000000000000000000 (39 bytes) 00000000500cd 10:57:44.794 SERIAL » [ACK] (0x06) 10:57:44.795 DRIVER « [RES] [GetSerialApiInitData] payload: 0x05081d05e4dfe07f00a0000000000000000000000000000000000000000000000 500 10:57:44.800 CNTRLR received node information: controller role: primary controller is a SUC: true controller is a slave: false controller supports timers: false nodes in the network: 1, 3, 11, 14, 15, 16, 17, 18, 19, 20, 21, 23, 24 , 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 54, 56 10:57:44.871 DRIVER Cache file for homeId 0xdd454af5 found, attempting to restore the network from cache... 10:57:44.882 CNTRLR [Node 001] trying to load device config 10:57:44.893 CNTRLR [Node 001] device config loaded 10:57:44.894 CNTRLR [Node 003] trying to load device config 10:57:44.903 CNTRLR [Node 003] device config loaded 10:57:44.904 CNTRLR [Node 014] trying to load device config 10:57:44.919 CNTRLR [Node 014] device config loaded 10:57:44.920 CNTRLR [Node 016] trying to load device config 10:57:44.945 CNTRLR [Node 016] device config loaded 10:57:44.946 CNTRLR [Node 017] trying to load device config 10:57:44.959 CNTRLR [Node 017] device config loaded 10:57:44.961 CNTRLR [Node 020] trying to load device config 10:57:44.977 CNTRLR [Node 020] device config loaded 10:57:44.978 CNTRLR [Node 021] trying to load device config 10:57:44.993 CNTRLR [Node 021] device config loaded 10:57:44.994 CNTRLR [Node 023] trying to load device config 10:57:45.000 CNTRLR [Node 023] device config loaded 10:57:45.002 CNTRLR [Node 031] trying to load device config 10:57:45.011 CNTRLR [Node 031] device config loaded 10:57:45.013 CNTRLR [Node 033] trying to load device config 10:57:45.015 CNTRLR [Node 033] no device config loaded 10:57:45.016 CNTRLR [Node 034] trying to load device config 10:57:45.019 CNTRLR [Node 034] no device config loaded 10:57:45.020 CNTRLR [Node 035] trying to load device config 10:57:45.022 CNTRLR [Node 035] no device config loaded 10:57:45.023 CNTRLR [Node 036] trying to load device config 10:57:45.026 CNTRLR [Node 036] no device config loaded 10:57:45.026 CNTRLR [Node 037] trying to load device config 10:57:45.029 CNTRLR [Node 037] no device config loaded 10:57:45.030 CNTRLR [Node 038] trying to load device config 10:57:45.034 CNTRLR [Node 038] no device config loaded 10:57:45.035 CNTRLR [Node 039] trying to load device config 10:57:45.038 CNTRLR [Node 039] no device config loaded 10:57:45.039 CNTRLR [Node 054] trying to load device config 10:57:45.060 CNTRLR [Node 054] device config loaded 10:57:45.064 CNTRLR [Node 056] trying to load device config 10:57:45.086 CNTRLR [Node 056] device config loaded 10:57:45.086 DRIVER Restoring the network from cache was successful! 10:57:45.091 CNTRLR [Node 001] [Manufacturer Specific] manufacturerId: metadata updated 10:57:45.092 CNTRLR [Node 001] [Manufacturer Specific] productType: metadata updated 10:57:45.093 CNTRLR [Node 001] [Manufacturer Specific] productId: metadata updated 10:57:45.094 CNTRLR [Node 001] [~] [Manufacturer Specific] manufacturerId: 277 => 277 10:57:45.095 CNTRLR [Node 001] [~] [Manufacturer Specific] productType: 1024 => 1024 10:57:45.096 CNTRLR [Node 001] [~] [Manufacturer Specific] productId: 1 => 1 10:57:45.096 CNTRLR setting serial API timeouts: ack = 1000 ms, byte = 150 ms 10:57:45.102 SERIAL » 0x01050006640f97 (7 bytes) 10:57:45.103 DRIVER » [REQ] [SetSerialApiTimeouts] payload: 0x640f 10:57:45.105 SERIAL « [ACK] (0x06) 10:57:45.107 SERIAL « 0x01050106640f96 (7 bytes) 10:57:45.108 SERIAL » [ACK] (0x06) 10:57:45.109 DRIVER « [RES] [SetSerialApiTimeouts] payload: 0x640f 10:57:45.113 CNTRLR serial API timeouts overwritten. The old values were: ack = 1000 ms, byte = 15 0 ms 10:57:45.113 CNTRLR Interview completed 10:57:45.116 DRIVER driver ready 10:57:45.122 CNTRLR [Node 001] Beginning interview - last completed stage: RestartFromCache 10:57:45.123 CNTRLR [Node 001] not pinging the controller 10:57:45.152 CNTRLR [Node 001] Interview stage completed: CommandClasses 10:57:45.154 CNTRLR [Node 001] trying to load device config 10:57:45.160 CNTRLR [Node 001] device config loaded 10:57:45.162 CNTRLR [Node 001] Interview stage completed: OverwriteConfig 10:57:45.163 CNTRLR » [Node 001] requesting node neighbors... 10:57:45.240 SERIAL » 0x010700800100000079 (9 bytes) 10:57:45.240 DRIVER » [Node 001] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 10:57:45.245 SERIAL « [ACK] (0x06) 10:57:45.250 SERIAL « 0x012001800060dea00300a00000000000000000000000000000000000000000000 (34 bytes) 0e3 10:57:45.251 SERIAL » [ACK] (0x06) 10:57:45.253 DRIVER « [RES] [GetRoutingInfo] node ids: 14, 15, 18, 19, 20, 21, 23, 24, 30, 32, 33, 34, 54, 56 10:57:45.259 CNTRLR [Node 001] The node is alive. 10:57:45.260 CNTRLR [Node 001] The node is ready to be used 10:57:45.261 CNTRLR « [Node 001] node neighbors received: 14, 15, 18, 19, 20, 21, 23, 24, 30, 32, 33, 34, 54, 56 10:57:45.262 CNTRLR [Node 001] Interview stage completed: Neighbors 10:57:45.262 CNTRLR [Node 001] Interview completed 10:57:45.264 CNTRLR [Node 003] Beginning interview - last completed stage: RestartFromCache 10:57:45.265 CNTRLR » [Node 003] pinging the node... 10:57:45.276 SERIAL » 0x010800130301002501c2 (10 bytes) 10:57:45.277 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 1 └─[NoOperationCC] 10:57:45.278 CNTRLR [Node 011] Beginning interview - last completed stage: ProtocolInfo 10:57:45.278 CNTRLR » [Node 011] pinging the node... 10:57:45.281 CNTRLR [Node 014] Beginning interview - last completed stage: RestartFromCache 10:57:45.282 CNTRLR » [Node 014] pinging the node... 10:57:45.286 CNTRLR [Node 015] Beginning interview - last completed stage: ProtocolInfo 10:57:45.286 CNTRLR » [Node 015] pinging the node... 10:57:45.289 CNTRLR [Node 016] Beginning interview - last completed stage: RestartFromCache 10:57:45.290 CNTRLR » [Node 016] pinging the node... 10:57:45.292 CNTRLR [Node 017] Beginning interview - last completed stage: RestartFromCache 10:57:45.293 CNTRLR » [Node 017] pinging the node... 10:57:45.296 CNTRLR [Node 018] Beginning interview - last completed stage: ProtocolInfo 10:57:45.296 CNTRLR » [Node 018] pinging the node... 10:57:45.299 CNTRLR [Node 019] Beginning interview - last completed stage: RestartFromCache 10:57:45.300 CNTRLR » [Node 019] pinging the node... 10:57:45.302 CNTRLR [Node 020] Beginning interview - last completed stage: RestartFromCache 10:57:45.303 CNTRLR » [Node 020] pinging the node... 10:57:45.306 CNTRLR [Node 021] Beginning interview - last completed stage: RestartFromCache 10:57:45.307 CNTRLR » [Node 021] pinging the node... 10:57:45.310 CNTRLR [Node 023] Beginning interview - last completed stage: NodeInfo 10:57:45.317 CNTRLR [Node 023] ManufacturerSpecificCC: doing a partial interview... 10:57:45.318 CNTRLR [Node 023] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 10:57:45.318 CNTRLR [Node 024] Beginning interview - last completed stage: ProtocolInfo 10:57:45.318 CNTRLR » [Node 024] pinging the node... 10:57:45.331 CNTRLR [Node 030] Beginning interview - last completed stage: ProtocolInfo 10:57:45.331 CNTRLR » [Node 030] pinging the node... 10:57:45.334 CNTRLR [Node 031] Beginning interview - last completed stage: RestartFromCache 10:57:45.334 CNTRLR » [Node 031] pinging the node... 10:57:45.337 CNTRLR [Node 032] Beginning interview - last completed stage: NodeInfo 10:57:45.341 CNTRLR [Node 032] ManufacturerSpecificCC: doing a complete interview... 10:57:45.341 CNTRLR » [Node 032] querying manufacturer information... 10:57:45.349 CNTRLR [Node 033] Beginning interview - last completed stage: RestartFromCache 10:57:45.350 CNTRLR » [Node 033] pinging the node... 10:57:45.353 CNTRLR [Node 034] Beginning interview - last completed stage: RestartFromCache 10:57:45.354 CNTRLR » [Node 034] pinging the node... 10:57:45.356 CNTRLR [Node 035] Beginning interview - last completed stage: RestartFromCache 10:57:45.357 CNTRLR » [Node 035] pinging the node... 10:57:45.360 CNTRLR [Node 036] Beginning interview - last completed stage: RestartFromCache 10:57:45.361 CNTRLR » [Node 036] pinging the node... 10:57:45.364 CNTRLR [Node 037] Beginning interview - last completed stage: RestartFromCache 10:57:45.364 CNTRLR » [Node 037] pinging the node... 10:57:45.367 CNTRLR [Node 038] Beginning interview - last completed stage: RestartFromCache 10:57:45.368 CNTRLR » [Node 038] pinging the node... 10:57:45.371 CNTRLR [Node 039] Beginning interview - last completed stage: RestartFromCache 10:57:45.371 CNTRLR » [Node 039] pinging the node... 10:57:45.374 CNTRLR [Node 054] Beginning interview - last completed stage: RestartFromCache 10:57:45.375 CNTRLR » [Node 054] pinging the node... 10:57:45.377 CNTRLR [Node 056] Beginning interview - last completed stage: RestartFromCache 10:57:45.378 CNTRLR » [Node 056] pinging the node... 10:57:45.401 SERIAL « [ACK] (0x06) 10:57:45.409 CNTRLR [Node 023] VersionCC: doing a partial interview... 10:57:45.410 CNTRLR [Node 023] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 10:57:45.411 CNTRLR [Node 023] trying to load device config 10:57:45.422 CNTRLR [Node 023] device config loaded 10:57:45.423 CNTRLR [Node 023] BatteryCC: doing a partial interview... 10:57:45.424 CNTRLR » [Node 023] querying battery status... 10:57:45.666 SERIAL « 0x0104011301e8 (6 bytes) 10:57:45.667 SERIAL » [ACK] (0x06) 10:57:45.668 DRIVER « [RES] [SendData] was sent: true 10:57:53.652 SERIAL « 0x010f00040036097105000000ff0708004f (17 bytes) 10:57:53.658 SERIAL » [ACK] (0x06) 10:57:53.663 DRIVER « [Node 054] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 10:57:53.675 CNTRLR [Node 054] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 10:57:53.959 SERIAL « 0x010f00041036097105000000ff0708005f (17 bytes) 10:57:53.961 SERIAL » [ACK] (0x06) 10:57:53.963 DRIVER « [Node 054] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 10:57:53.968 CNTRLR [Node 054] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 8 10:57:54.866 SERIAL « 0x010900040014033003ff29 (11 bytes) 10:57:54.869 CNTRLR [Node 020] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:57:54.871 CNTRLR [Node 020] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:57:54.872 SERIAL » [ACK] (0x06) 10:57:54.875 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:57:54.980 SERIAL « 0x010900040014032001ff3b (11 bytes) 10:57:54.982 SERIAL » [ACK] (0x06) 10:57:54.984 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:57:54.989 CNTRLR [Node 020] treating BasicCC Set as a report 10:57:54.990 CNTRLR [Node 020] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:57:57.821 SERIAL « 0x01070013010104dc33 (9 bytes) 10:57:57.822 SERIAL » [ACK] (0x06) 10:57:57.825 DRIVER « [REQ] [SendData] callback id: 1 transmit status: NoAck 10:57:57.853 SERIAL » 0x010800133801002502fa (10 bytes) 10:57:57.854 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 2 └─[NoOperationCC] 10:57:57.855 CNTRLR [Node 003] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 10:57:57.865 CNTRLR [Node 003] The node is asleep. 10:57:57.869 CNTRLR [Node 003] The node is ready to be used 10:57:57.871 CNTRLR [Node 003] ping failed: Failed to send the command after 1 attempts (Status No Ack) 10:57:57.875 CNTRLR [Node 003] ManufacturerSpecificCC: doing a partial interview... 10:57:57.876 CNTRLR [Node 003] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 10:57:57.892 SERIAL « [ACK] (0x06) 10:57:57.894 SERIAL « 0x0104011301e8 (6 bytes) 10:57:57.895 SERIAL » [ACK] (0x06) 10:57:57.897 DRIVER « [RES] [SendData] was sent: true 10:57:57.902 CNTRLR [Node 003] VersionCC: doing a partial interview... 10:57:57.903 CNTRLR [Node 003] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 10:57:57.903 CNTRLR [Node 003] trying to load device config 10:57:57.928 SERIAL « 0x0107001302000003ea (9 bytes) 10:57:57.929 SERIAL » [ACK] (0x06) 10:57:57.930 DRIVER « [REQ] [SendData] callback id: 2 transmit status: OK 10:57:57.947 SERIAL » 0x0109001320027204250397 (11 bytes) 10:57:57.948 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 3 └─[ManufacturerSpecificCCGet] 10:57:57.949 CNTRLR « [Node 056] ping successful 10:57:57.954 CNTRLR [Node 056] ManufacturerSpecificCC: doing a partial interview... 10:57:57.955 CNTRLR [Node 056] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 10:57:57.956 CNTRLR [Node 056] VersionCC: doing a partial interview... 10:57:57.957 CNTRLR [Node 056] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 10:57:57.957 CNTRLR [Node 056] trying to load device config 10:57:57.963 SERIAL « [ACK] (0x06) 10:57:57.976 SERIAL « 0x0104011301e8 (6 bytes) 10:57:57.976 SERIAL » [ACK] (0x06) 10:57:57.978 DRIVER « [RES] [SendData] was sent: true 10:57:57.993 CNTRLR [Node 003] device config loaded 10:57:57.996 CNTRLR [Node 003] ZWavePlusCC: doing a partial interview... 10:57:57.997 CNTRLR [Node 003] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 10:57:57.998 CNTRLR [Node 003] BatteryCC: doing a partial interview... 10:57:57.999 CNTRLR » [Node 003] querying battery status... 10:57:58.054 CNTRLR [Node 056] device config loaded 10:57:58.077 CNTRLR [Node 056] ZWavePlusCC: doing a partial interview... 10:57:58.078 CNTRLR [Node 056] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 10:57:58.081 CNTRLR » [Node 056] querying device endpoint information... 10:58:02.057 SERIAL « 0x010700130301019a72 (9 bytes) 10:58:02.058 SERIAL » [ACK] (0x06) 10:58:02.059 DRIVER « [REQ] [SendData] callback id: 3 transmit status: NoAck 10:58:02.065 CNTRLR [Node 032] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 10:58:02.571 SERIAL » 0x0109001320027204250397 (11 bytes) 10:58:02.572 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 3 └─[ManufacturerSpecificCCGet] 10:58:02.574 SERIAL « [ACK] (0x06) 10:58:02.583 SERIAL « 0x0104011301e8 (6 bytes) 10:58:02.584 SERIAL » [ACK] (0x06) 10:58:02.584 DRIVER « [RES] [SendData] was sent: true 10:58:06.713 SERIAL « 0x010700130301019e76 (9 bytes) 10:58:06.714 SERIAL » [ACK] (0x06) 10:58:06.715 DRIVER « [REQ] [SendData] callback id: 3 transmit status: NoAck 10:58:06.722 CNTRLR [Node 032] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 10:58:07.236 SERIAL » 0x0109001320027204250397 (11 bytes) 10:58:07.238 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 3 └─[ManufacturerSpecificCCGet] 10:58:07.241 SERIAL « [ACK] (0x06) 10:58:07.249 SERIAL « 0x0104011301e8 (6 bytes) 10:58:07.250 SERIAL » [ACK] (0x06) 10:58:07.251 DRIVER « [RES] [SendData] was sent: true 10:58:11.362 SERIAL « 0x010700130301019c74 (9 bytes) 10:58:11.363 SERIAL » [ACK] (0x06) 10:58:11.363 DRIVER « [REQ] [SendData] callback id: 3 transmit status: NoAck 10:58:11.370 SERIAL » 0x0109001338026007250499 (11 bytes) 10:58:11.371 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 4 └─[MultiChannelCCEndPointGet] 10:58:11.371 CNTRLR [Node 032] Node 32 did not respond after 3 attempts, it is presumed dead 10:58:11.372 CNTRLR [Node 032] The node is dead. 10:58:11.375 CNTRLR [Node 032] Error during node interview: Failed to send the command after 3 att empts (Status NoAck) 10:58:11.377 SERIAL « [ACK] (0x06) 10:58:11.383 SERIAL « 0x0104011301e8 (6 bytes) 10:58:11.384 SERIAL » [ACK] (0x06) 10:58:11.385 DRIVER « [RES] [SendData] was sent: true 10:58:11.403 SERIAL « 0x0107001304000003ec (9 bytes) 10:58:11.403 SERIAL » [ACK] (0x06) 10:58:11.404 DRIVER « [REQ] [SendData] callback id: 4 transmit status: OK 10:58:11.421 SERIAL « 0x010b00040038056008000200a7 (13 bytes) 10:58:11.423 CNTRLR [Node 056] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 10:58:11.424 CNTRLR [Node 056] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 10:58:11.424 CNTRLR [Node 056] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 10:58:11.425 CNTRLR [Node 056] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 10:58:11.425 SERIAL » [ACK] (0x06) 10:58:11.427 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 10:58:11.433 SERIAL » 0x010800130b01002505ce (10 bytes) 10:58:11.434 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 5 └─[NoOperationCC] 10:58:11.434 CNTRLR [Node 056] The node is alive. 10:58:11.436 CNTRLR [Node 056] The node is ready to be used 10:58:11.438 CNTRLR « [Node 056] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 10:58:11.438 CNTRLR » [Node 056] querying all endpoints... 10:58:11.446 SERIAL « [ACK] (0x06) 10:58:11.765 SERIAL « 0x0104011301e8 (6 bytes) 10:58:11.766 SERIAL » [ACK] (0x06) 10:58:11.767 DRIVER « [RES] [SendData] was sent: true 10:58:20.862 SERIAL « 0x0110000400360a7105000000ff0700010852 (18 bytes) 10:58:20.863 SERIAL » [ACK] (0x06) 10:58:20.864 DRIVER « [Node 054] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  10:58:20.868 CNTRLR [Node 054] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 10:58:24.955 SERIAL « 0x0107001305010547ad (9 bytes) 10:58:24.956 SERIAL » [ACK] (0x06) 10:58:24.958 DRIVER « [REQ] [SendData] callback id: 5 transmit status: NoAck 10:58:24.972 SERIAL » 0x010800130e01002506c8 (10 bytes) 10:58:24.972 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 6 └─[NoOperationCC] 10:58:24.973 CNTRLR [Node 011] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 10:58:24.974 CNTRLR [Node 011] The node is asleep. 10:58:24.976 CNTRLR [Node 011] ping failed: Failed to send the command after 1 attempts (Status No Ack) 10:58:24.977 CNTRLR » [Node 011] querying node info... 10:58:24.987 SERIAL « [ACK] (0x06) 10:58:24.990 SERIAL « 0x0104011301e8 (6 bytes) 10:58:24.990 SERIAL » [ACK] (0x06) 10:58:24.991 DRIVER « [RES] [SendData] was sent: true 10:58:25.001 SERIAL « 0x0107001306000002ef (9 bytes) 10:58:25.002 SERIAL » [ACK] (0x06) 10:58:25.003 DRIVER « [REQ] [SendData] callback id: 6 transmit status: OK 10:58:25.015 SERIAL » 0x010b00133804600bffff250792 (13 bytes) 10:58:25.017 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 7 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 10:58:25.018 CNTRLR « [Node 014] ping successful 10:58:25.021 CNTRLR [Node 014] ManufacturerSpecificCC: doing a partial interview... 10:58:25.022 CNTRLR [Node 014] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 10:58:25.048 SERIAL « [ACK] (0x06) 10:58:25.053 SERIAL « 0x0104011301e8 (6 bytes) 10:58:25.054 SERIAL » [ACK] (0x06) 10:58:25.057 DRIVER « [RES] [SendData] was sent: true 10:58:25.062 CNTRLR [Node 014] VersionCC: doing a partial interview... 10:58:25.063 CNTRLR [Node 014] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 10:58:25.063 CNTRLR [Node 014] trying to load device config 10:58:25.066 SERIAL « 0x0107001307000002ee (9 bytes) 10:58:25.067 SERIAL » [ACK] (0x06) 10:58:25.068 DRIVER « [REQ] [SendData] callback id: 7 transmit status: OK 10:58:25.072 SERIAL « 0x010d0004003807600c00ffff0102a6 (15 bytes) 10:58:25.074 SERIAL » [ACK] (0x06) 10:58:25.091 CNTRLR [Node 014] device config loaded 10:58:25.093 CNTRLR [Node 014] AssociationCC: doing a partial interview... 10:58:25.095 CNTRLR [Node 014] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 10:58:25.097 CNTRLR [Node 014] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 10:58:25.098 CNTRLR [Node 014] BinarySwitchCC: doing a partial interview... 10:58:25.099 CNTRLR » [Node 014] querying Binary Switch state... 10:58:25.109 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 10:58:25.119 SERIAL » 0x010900130e0225022508e3 (11 bytes) 10:58:25.120 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 8 └─[BinarySwitchCCGet] 10:58:25.120 CNTRLR « [Node 056] received endpoints: 1, 2 10:58:25.121 CNTRLR » [Node 056] querying capabilities for endpoint #1... 10:58:25.126 SERIAL « [ACK] (0x06) 10:58:25.128 SERIAL « 0x0104011301e8 (6 bytes) 10:58:25.129 SERIAL » [ACK] (0x06) 10:58:25.130 DRIVER « [RES] [SendData] was sent: true 10:58:25.145 SERIAL « 0x0107001308000002e1 (9 bytes) 10:58:25.145 SERIAL » [ACK] (0x06) 10:58:25.146 DRIVER « [REQ] [SendData] callback id: 8 transmit status: OK 10:58:25.155 SERIAL « 0x01090004000e03250300d9 (11 bytes) 10:58:25.157 CNTRLR [Node 014] [~] [Binary Switch] currentValue: false => false [Endpoint 0] 10:58:25.158 SERIAL » [ACK] (0x06) 10:58:25.159 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 10:58:25.168 SERIAL » 0x010a00133803600901250999 (12 bytes) 10:58:25.168 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 9 └─[MultiChannelCCCapabilityGet] endpoint: 1 10:58:25.169 CNTRLR [Node 014] The node is alive. 10:58:25.170 CNTRLR [Node 014] The node is ready to be used 10:58:25.172 CNTRLR « [Node 014] received Binary Switch state: current value: false 10:58:25.173 CNTRLR [Node 014] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 10:58:25.174 CNTRLR [Node 014] MultilevelSensorCC: doing a partial interview... 10:58:25.175 CNTRLR » [Node 014] querying current sensor reading... 10:58:25.190 SERIAL « [ACK] (0x06) 10:58:25.192 SERIAL « 0x0104011301e8 (6 bytes) 10:58:25.192 SERIAL » [ACK] (0x06) 10:58:25.193 DRIVER « [RES] [SendData] was sent: true 10:58:25.202 SERIAL « 0x0107001309000003e1 (9 bytes) 10:58:25.202 SERIAL » [ACK] (0x06) 10:58:25.207 DRIVER « [REQ] [SendData] callback id: 9 transmit status: OK 10:58:25.280 SERIAL « 0x01160004003810600a0111065e26858e59989f6c32712299 (24 bytes) 10:58:25.282 CNTRLR [Node 056] [~] [Multi Channel] commandClasses: 94,38,1 [Endpoint 1] [internal] 33,142,89,152,159,108,50,113,34 => 94,38,133,142,89,152,159,108,50,113,34 10:58:25.283 SERIAL » [ACK] (0x06) 10:58:25.297 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Multilevel Switch specific device class: Motor Control Class B is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multilevel Switch · Association · Multi Channel Association · Association Group Information · Security · Security 2 · Supervision · Meter · Notification · Application Status 10:58:25.303 SERIAL » 0x010900130e023104250af3 (11 bytes) 10:58:25.304 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 10 └─[MultilevelSensorCCGet] 10:58:25.305 CNTRLR « [Node 056] received response for endpoint capabilities (#1): generic device class: Multilevel Switch specific device class: Motor Control Class B is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multilevel Switch · Association · Multi Channel Association · Association Group Information · Security · Security 2 · Supervision · Meter · Notification · Application Status 10:58:25.305 CNTRLR » [Node 056] querying capabilities for endpoint #2... 10:58:25.310 SERIAL « [ACK] (0x06) 10:58:25.313 SERIAL « 0x0104011301e8 (6 bytes) 10:58:25.314 SERIAL » [ACK] (0x06) 10:58:25.315 DRIVER « [RES] [SendData] was sent: true 10:58:25.330 SERIAL « 0x010700130a000003e2 (9 bytes) 10:58:25.330 SERIAL » [ACK] (0x06) 10:58:25.331 DRIVER « [REQ] [SendData] callback id: 10 transmit status: OK 10:58:25.343 SERIAL « 0x010c0004000e06310504220000ed (14 bytes) 10:58:25.346 CNTRLR [Node 014] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:58:25.347 CNTRLR [Node 014] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 10:58:25.348 SERIAL » [ACK] (0x06) 10:58:25.349 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 10:58:25.355 SERIAL » 0x010a00133803600902250b98 (12 bytes) 10:58:25.356 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 11 └─[MultiChannelCCCapabilityGet] endpoint: 2 10:58:25.356 CNTRLR « [Node 014] received current sensor reading: sensor type: Power value: 0 W 10:58:25.357 CNTRLR [Node 014] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 10:58:25.359 CNTRLR [Node 014] MeterCC: doing a partial interview... 10:58:25.360 CNTRLR » [Node 014] querying meter value (type = Electric, scale = kWh)... 10:58:25.381 SERIAL « [ACK] (0x06) 10:58:25.383 SERIAL « 0x0104011301e8 (6 bytes) 10:58:25.383 SERIAL » [ACK] (0x06) 10:58:25.384 DRIVER « [RES] [SendData] was sent: true 10:58:25.389 SERIAL « 0x010700130b000002e2 (9 bytes) 10:58:25.390 SERIAL » [ACK] (0x06) 10:58:25.391 DRIVER « [REQ] [SendData] callback id: 11 transmit status: OK 10:58:25.406 SERIAL « 0x0114000400380e600a0211065e26858e59989f6c22c5 (22 bytes) 10:58:25.407 CNTRLR [Node 056] [~] [Multi Channel] commandClasses: 94,38,1 [Endpoint 2] [internal] 33,142,89,152,159,108,34 => 94,38,133,142,89,152,159,108,34 10:58:25.407 SERIAL » [ACK] (0x06) 10:58:25.409 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Switch specific device class: Motor Control Class B is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multilevel Switch · Association · Multi Channel Association · Association Group Information · Security · Security 2 · Supervision · Application Status 10:58:25.418 SERIAL » 0x010a00130e03320100250cf1 (12 bytes) 10:58:25.419 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 12 └─[MeterCCGet] duration: kWh 10:58:25.420 CNTRLR « [Node 056] received response for endpoint capabilities (#2): generic device class: Multilevel Switch specific device class: Motor Control Class B is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multilevel Switch · Association · Multi Channel Association · Association Group Information · Security · Security 2 · Supervision · Application Status 10:58:25.421 CNTRLR [Node 056] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 10:58:25.424 CNTRLR [Node 056] ZWavePlusCC: doing a partial interview... [Endpoint 1] 10:58:25.425 CNTRLR [Node 056] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 10:58:25.426 CNTRLR [Node 056] MultilevelSwitchCC: doing a partial interview... [Endpoint 1] 10:58:25.426 CNTRLR » [Node 056] requesting current switch state... [Endpoint 1] 10:58:25.440 SERIAL « [ACK] (0x06) 10:58:25.443 SERIAL « 0x0104011301e8 (6 bytes) 10:58:25.443 SERIAL » [ACK] (0x06) 10:58:25.444 DRIVER « [RES] [SendData] was sent: true 10:58:25.452 SERIAL « 0x010700130c000002e5 (9 bytes) 10:58:25.452 SERIAL » [ACK] (0x06) 10:58:25.454 DRIVER « [REQ] [SendData] callback id: 12 transmit status: OK 10:58:25.459 SERIAL « 0x01100004000e0a32022144000005500000ef (18 bytes) 10:58:25.462 CNTRLR [Node 014] [~] [Meter] value[65537]: 13.6 => 13.6 [Endpoint 0] 10:58:25.463 CNTRLR [Node 014] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 10:58:25.464 SERIAL » [ACK] (0x06) 10:58:25.466 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 13.6 time delta: 0 seconds 10:58:25.472 SERIAL » 0x010d00133806600d00012602250dbf (15 bytes) 10:58:25.473 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 13 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[MultilevelSwitchCCGet] 10:58:25.473 CNTRLR » [Node 014] querying meter value (type = Electric, scale = W)... 10:58:25.481 SERIAL « [ACK] (0x06) 10:58:25.484 SERIAL « 0x0104011301e8 (6 bytes) 10:58:25.484 SERIAL » [ACK] (0x06) 10:58:25.485 DRIVER « [RES] [SendData] was sent: true 10:58:25.502 SERIAL « 0x010700130d000003e5 (9 bytes) 10:58:25.502 SERIAL » [ACK] (0x06) 10:58:25.503 DRIVER « [REQ] [SendData] callback id: 13 transmit status: OK 10:58:25.681 SERIAL « 0x01090004001403300300d6 (11 bytes) 10:58:25.683 CNTRLR [Node 020] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:58:25.684 CNTRLR [Node 020] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:58:25.685 SERIAL » [ACK] (0x06) 10:58:25.688 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:58:25.728 SERIAL « 0x01090004001403200100c4 (11 bytes) 10:58:25.729 SERIAL » [ACK] (0x06) 10:58:25.730 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 10:58:25.732 CNTRLR [Node 020] treating BasicCC Set as a report 10:58:25.733 CNTRLR [Node 020] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:58:25.952 SERIAL « 0x010f0004003809600d010026036363fe72 (17 bytes) 10:58:25.956 CNTRLR [Node 056] [~] [Multilevel Switch] targetValue: 99 => 99 [Endpoint 1] 10:58:25.958 CNTRLR [Node 056] [~] [Multilevel Switch] duration: [Duration: unknown] [Endpoint 1] => [Duration: unknown] 10:58:25.959 CNTRLR [Node 056] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 1] 10:58:25.960 SERIAL » [ACK] (0x06) 10:58:25.964 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[MultilevelSwitchCCReport] current value: 99 target value: 99 duration: [Duration: unknown] 10:58:25.970 SERIAL » 0x010a00130e03320110250ee3 (12 bytes) 10:58:25.971 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 14 └─[MeterCCGet] duration: W 10:58:25.972 CNTRLR [Node 056] [~] [Multilevel Switch] interviewComplete: [Endpoint 1] [internal] true => true 10:58:25.995 SERIAL « [ACK] (0x06) 10:58:26.002 SERIAL « 0x0104011301e8 (6 bytes) 10:58:26.003 SERIAL » [ACK] (0x06) 10:58:26.008 DRIVER « [RES] [SendData] was sent: true 10:58:26.013 CNTRLR [Node 056] MeterCC: doing a partial interview... [Endpoint 1] 10:58:26.014 CNTRLR » [Node 056] querying meter value (type = Electric, scale = kWh)... [Endpoint 1] 10:58:26.026 SERIAL « 0x010700130e000002e7 (9 bytes) 10:58:26.027 SERIAL » [ACK] (0x06) 10:58:26.029 DRIVER « [REQ] [SendData] callback id: 14 transmit status: OK 10:58:26.035 SERIAL « 0x010e0004000e083202213200000000d0 (16 bytes) 10:58:26.037 CNTRLR [Node 014] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 10:58:26.038 CNTRLR [Node 014] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 10:58:26.039 SERIAL » [ACK] (0x06) 10:58:26.041 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 10:58:26.049 SERIAL » 0x010e00133807600d0001320100250fa8 (16 bytes) 10:58:26.049 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 15 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[MeterCCGet] duration: kWh 10:58:26.050 CNTRLR [Node 014] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 10:58:26.052 CNTRLR [Node 014] ConfigurationCC: Loading configuration parameters from device confi g 10:58:26.055 CNTRLR [Node 014] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 10:58:26.058 CNTRLR [Node 014] [Configuration] 1: metadata updated 10:58:26.060 CNTRLR [Node 014] [Configuration] 16: metadata updated 10:58:26.061 CNTRLR [Node 014] [Configuration] 34: metadata updated 10:58:26.063 CNTRLR [Node 014] [Configuration] 35: metadata updated 10:58:26.065 CNTRLR [Node 014] [Configuration] 39: metadata updated 10:58:26.066 CNTRLR [Node 014] [Configuration] 40: metadata updated 10:58:26.068 CNTRLR [Node 014] [Configuration] 42: metadata updated 10:58:26.071 CNTRLR [Node 014] [Configuration] 43: metadata updated 10:58:26.073 CNTRLR [Node 014] [Configuration] 45: metadata updated 10:58:26.077 CNTRLR [Node 014] [Configuration] 47: metadata updated 10:58:26.079 CNTRLR [Node 014] [Configuration] 49: metadata updated 10:58:26.083 CNTRLR [Node 014] [Configuration] 50: metadata updated 10:58:26.085 CNTRLR [Node 014] [Configuration] 51: metadata updated 10:58:26.089 CNTRLR [Node 014] [Configuration] 52: metadata updated 10:58:26.091 CNTRLR [Node 014] [Configuration] 60: metadata updated 10:58:26.094 CNTRLR [Node 014] [Configuration] 61: metadata updated 10:58:26.097 CNTRLR [Node 014] [Configuration] 62: metadata updated 10:58:26.100 CNTRLR [Node 014] [Configuration] 63: metadata updated 10:58:26.103 CNTRLR [Node 014] [Configuration] 70: metadata updated 10:58:26.105 CNTRLR [Node 014] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 10:58:26.107 CNTRLR » [Node 014] querying parameter #1 value... 10:58:26.150 SERIAL « [ACK] (0x06) 10:58:26.152 SERIAL « 0x0104011301e8 (6 bytes) 10:58:26.153 SERIAL » [ACK] (0x06) 10:58:26.158 DRIVER « [RES] [SendData] was sent: true 10:58:26.206 SERIAL « 0x010700130f000003e7 (9 bytes) 10:58:26.207 SERIAL » [ACK] (0x06) 10:58:26.214 DRIVER « [REQ] [SendData] callback id: 15 transmit status: OK 10:58:26.236 SERIAL « 0x01180004003812600d01003202214400000009000000000000f9 (26 bytes) 10:58:26.238 CNTRLR [Node 056] [~] [Meter] value[65537]: 0.09 => 0.09 [Endpoint 1] 10:58:26.239 CNTRLR [Node 056] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 1] 10:58:26.240 SERIAL » [ACK] (0x06) 10:58:26.245 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 0.09 time delta: 0 seconds 10:58:26.261 SERIAL » 0x010a00130e037005012510aa (12 bytes) 10:58:26.263 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[ConfigurationCCGet] parameter #: 1 10:58:26.263 CNTRLR » [Node 056] querying meter value (type = Electric, scale = W)... [Endpoint 1] 10:58:26.272 SERIAL « [ACK] (0x06) 10:58:26.274 SERIAL « 0x0104011301e8 (6 bytes) 10:58:26.275 SERIAL » [ACK] (0x06) 10:58:26.277 DRIVER « [RES] [SendData] was sent: true 10:58:26.288 SERIAL « 0x0107001310000003f8 (9 bytes) 10:58:26.288 SERIAL » [ACK] (0x06) 10:58:26.289 DRIVER « [REQ] [SendData] callback id: 16 transmit status: OK 10:58:26.299 SERIAL « 0x010b0004000e0570060101018c (13 bytes) 10:58:26.304 CNTRLR [Node 014] [~] [Configuration] 1: 1 => 1 10:58:26.306 SERIAL » [ACK] (0x06) 10:58:26.309 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 1 10:58:26.316 SERIAL » 0x010e00133807600d00013201102511a6 (16 bytes) 10:58:26.317 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 17 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[MeterCCGet] duration: W 10:58:26.318 CNTRLR « [Node 014] parameter #1 has value: 1 10:58:26.318 CNTRLR » [Node 014] querying parameter #16 value... 10:58:26.335 SERIAL « [ACK] (0x06) 10:58:26.337 SERIAL « 0x0104011301e8 (6 bytes) 10:58:26.337 SERIAL » [ACK] (0x06) 10:58:26.338 DRIVER « [RES] [SendData] was sent: true 10:58:26.348 SERIAL « 0x0107001311000003f9 (9 bytes) 10:58:26.349 SERIAL » [ACK] (0x06) 10:58:26.350 DRIVER « [REQ] [SendData] callback id: 17 transmit status: OK 10:58:26.401 SERIAL « 0x0114000400380e600d01003202213200000000000096 (22 bytes) 10:58:26.402 CNTRLR [Node 056] [~] [Meter] value[66049]: 0 => 0 [Endpoint 1] 10:58:26.404 CNTRLR [Node 056] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 1] 10:58:26.404 SERIAL » [ACK] (0x06) 10:58:26.407 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 10:58:26.413 SERIAL » 0x010a00130e037005102512b9 (12 bytes) 10:58:26.414 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 18 └─[ConfigurationCCGet] parameter #: 16 10:58:26.415 CNTRLR [Node 056] [~] [Meter] interviewComplete: true => true [Endpoint 1] [internal] 10:58:26.431 SERIAL « [ACK] (0x06) 10:58:26.446 SERIAL « 0x0104011301e8 (6 bytes) 10:58:26.447 SERIAL » [ACK] (0x06) 10:58:26.452 DRIVER « [RES] [SendData] was sent: true 10:58:26.460 CNTRLR [Node 056] NotificationCC: doing a partial interview... [Endpoint 1] 10:58:26.461 CNTRLR » [Node 056] querying notification status for Power Management... [Endpoint 1] 10:58:26.481 SERIAL « 0x0107001312000002fb (9 bytes) 10:58:26.481 SERIAL » [ACK] (0x06) 10:58:26.483 DRIVER « [REQ] [SendData] callback id: 18 transmit status: OK 10:58:26.493 SERIAL « 0x010b0004000e0570061001019d (13 bytes) 10:58:26.496 CNTRLR [Node 014] [~] [Configuration] 16: 1 => 1 10:58:26.497 SERIAL » [ACK] (0x06) 10:58:26.498 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 1 10:58:26.506 SERIAL » 0x011000133809600d000171040008002513ea (18 bytes) 10:58:26.508 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 19 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: Power Management 10:58:26.508 CNTRLR « [Node 014] parameter #16 has value: 1 10:58:26.509 CNTRLR » [Node 014] querying parameter #34 value... 10:58:26.518 SERIAL « [ACK] (0x06) 10:58:26.520 SERIAL « 0x0104011301e8 (6 bytes) 10:58:26.521 SERIAL » [ACK] (0x06) 10:58:26.522 DRIVER « [RES] [SendData] was sent: true 10:58:26.538 SERIAL « 0x0107001313000003fb (9 bytes) 10:58:26.539 SERIAL » [ACK] (0x06) 10:58:26.540 DRIVER « [REQ] [SendData] callback id: 19 transmit status: OK 10:58:26.559 SERIAL « 0x0113000400380d600d01007105000000ff08fe00cc (21 bytes) 10:58:26.560 SERIAL » [ACK] (0x06) 10:58:26.562 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 10:58:26.567 SERIAL » 0x010a00130e0370052225148d (12 bytes) 10:58:26.568 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 20 └─[ConfigurationCCGet] parameter #: 34 10:58:26.569 CNTRLR [Node 056] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 1] 54 10:58:26.570 CNTRLR » [Node 056] querying notification status for System... [Endpoint 1] 10:58:26.582 SERIAL « [ACK] (0x06) 10:58:26.584 SERIAL « 0x0104011301e8 (6 bytes) 10:58:26.584 SERIAL » [ACK] (0x06) 10:58:26.586 DRIVER « [RES] [SendData] was sent: true 10:58:26.593 SERIAL « 0x0107001314000002fd (9 bytes) 10:58:26.594 SERIAL » [ACK] (0x06) 10:58:26.594 DRIVER « [REQ] [SendData] callback id: 20 transmit status: OK 10:58:26.604 SERIAL « 0x010b0004000e05700622013f91 (13 bytes) 10:58:26.607 CNTRLR [Node 014] [~] [Configuration] 34: 63 => 63 10:58:26.608 SERIAL » [ACK] (0x06) 10:58:26.610 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 34 value size: 1 value: 63 10:58:26.615 SERIAL » 0x011000133809600d000171040009002515ed (18 bytes) 10:58:26.615 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 21 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: System 10:58:26.616 CNTRLR « [Node 014] parameter #34 has value: 63 10:58:26.616 CNTRLR » [Node 014] querying parameter #35 value... 10:58:26.626 SERIAL « [ACK] (0x06) 10:58:26.628 SERIAL « 0x0104011301e8 (6 bytes) 10:58:26.628 SERIAL » [ACK] (0x06) 10:58:26.629 DRIVER « [RES] [SendData] was sent: true 10:58:26.646 SERIAL « 0x0107001315000002fc (9 bytes) 10:58:26.646 SERIAL » [ACK] (0x06) 10:58:26.647 DRIVER « [REQ] [SendData] callback id: 21 transmit status: OK 10:58:26.665 SERIAL « 0x0113000400380d600d01007105000000ff09fe00cd (21 bytes) 10:58:26.666 SERIAL » [ACK] (0x06) 10:58:26.667 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: System notification status: 255 notification event: Unknown (0xfe) 10:58:26.672 SERIAL » 0x010a00130e0370052325168e (12 bytes) 10:58:26.672 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 22 └─[ConfigurationCCGet] parameter #: 35 10:58:26.673 CNTRLR [Node 056] [~] [Notification] System[unknown]: 254 => 254 [Endpoint 1] 10:58:26.674 CNTRLR [Node 056] [~] [Notification] interviewComplete: true [Endpoint 1] [internal] => true 10:58:26.689 SERIAL « [ACK] (0x06) 10:58:26.693 SERIAL « 0x0104011301e8 (6 bytes) 10:58:26.693 SERIAL » [ACK] (0x06) 10:58:26.695 DRIVER « [RES] [SendData] was sent: true 10:58:26.699 CNTRLR [Node 056] ZWavePlusCC: doing a partial interview... [Endpoint 2] 10:58:26.700 CNTRLR [Node 056] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 10:58:26.701 CNTRLR [Node 056] MultilevelSwitchCC: doing a partial interview... [Endpoint 2] 10:58:26.701 CNTRLR » [Node 056] requesting current switch state... [Endpoint 2] 10:58:26.704 SERIAL « 0x0107001316000003fe (9 bytes) 10:58:26.704 SERIAL » [ACK] (0x06) 10:58:26.705 DRIVER « [REQ] [SendData] callback id: 22 transmit status: OK 10:58:26.711 SERIAL « 0x010b0004000e057006230100af (13 bytes) 10:58:26.714 CNTRLR [Node 014] [~] [Configuration] 35: 0 => 0 10:58:26.715 SERIAL » [ACK] (0x06) 10:58:26.717 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 0 10:58:26.722 SERIAL » 0x010d00133806600d000226022517a6 (15 bytes) 10:58:26.723 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 23 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MultilevelSwitchCCGet] 10:58:26.724 CNTRLR « [Node 014] parameter #35 has value: 0 10:58:26.724 CNTRLR » [Node 014] querying parameter #39 value... 10:58:26.732 SERIAL « [ACK] (0x06) 10:58:26.737 SERIAL « 0x0104011301e8 (6 bytes) 10:58:26.738 SERIAL » [ACK] (0x06) 10:58:26.739 DRIVER « [RES] [SendData] was sent: true 10:58:26.752 SERIAL « 0x0107001317000003ff (9 bytes) 10:58:26.753 SERIAL » [ACK] (0x06) 10:58:26.753 DRIVER « [REQ] [SendData] callback id: 23 transmit status: OK 10:58:26.800 SERIAL « 0x010f0004003809600d020026036363fe71 (17 bytes) 10:58:26.801 CNTRLR [Node 056] [~] [Multilevel Switch] targetValue: 99 => 99 [Endpoint 2] 10:58:26.802 CNTRLR [Node 056] [~] [Multilevel Switch] duration: [Duration: unknown] [Endpoint 2] => [Duration: unknown] 10:58:26.803 CNTRLR [Node 056] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 2] 10:58:26.803 SERIAL » [ACK] (0x06) 10:58:26.807 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSwitchCCReport] current value: 99 target value: 99 duration: [Duration: unknown] 10:58:26.821 SERIAL » 0x010a00130e03700527251884 (12 bytes) 10:58:26.822 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 24 └─[ConfigurationCCGet] parameter #: 39 10:58:26.823 CNTRLR [Node 056] [~] [Multilevel Switch] interviewComplete: [Endpoint 2] [internal] true => true 10:58:26.824 CNTRLR [Node 056] MultilevelSwitchCC: doing a partial interview... 10:58:26.824 CNTRLR » [Node 056] requesting current switch state... 10:58:26.830 SERIAL « [ACK] (0x06) 10:58:26.832 SERIAL « 0x0104011301e8 (6 bytes) 10:58:26.833 SERIAL » [ACK] (0x06) 10:58:26.834 DRIVER « [RES] [SendData] was sent: true 10:58:26.847 SERIAL « 0x0107001318000002f1 (9 bytes) 10:58:26.847 SERIAL » [ACK] (0x06) 10:58:26.848 DRIVER « [REQ] [SendData] callback id: 24 transmit status: OK 10:58:26.862 SERIAL « 0x010c0004000e06700627020258f6 (14 bytes) 10:58:26.865 CNTRLR [Node 014] [~] [Configuration] 39: 600 => 600 10:58:26.866 SERIAL » [ACK] (0x06) 10:58:26.868 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 39 value size: 2 value: 600 10:58:26.873 SERIAL » 0x01090013380226022519c7 (11 bytes) 10:58:26.874 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 25 └─[MultilevelSwitchCCGet] 10:58:26.875 CNTRLR « [Node 014] parameter #39 has value: 600 10:58:26.875 CNTRLR » [Node 014] querying parameter #40 value... 10:58:26.891 SERIAL « [ACK] (0x06) 10:58:26.893 SERIAL « 0x0104011301e8 (6 bytes) 10:58:26.896 SERIAL » [ACK] (0x06) 10:58:26.898 DRIVER « [RES] [SendData] was sent: true 10:58:26.907 SERIAL « 0x0107001319000003f1 (9 bytes) 10:58:26.912 SERIAL » [ACK] (0x06) 10:58:26.914 DRIVER « [REQ] [SendData] callback id: 25 transmit status: OK 10:58:26.948 SERIAL « 0x010b000400380526036363fe16 (13 bytes) 10:58:26.949 CNTRLR [Node 056] [~] [Multilevel Switch] targetValue: 0 => 99 [Endpoint 0] 10:58:26.950 CNTRLR [Node 056] [~] [Multilevel Switch] duration: [Duration: unknown] [Endpoint 0] => [Duration: unknown] 10:58:26.951 CNTRLR [Node 056] [~] [Multilevel Switch] currentValue: 0 => 99 [Endpoint 0] 10:58:26.951 SERIAL » [ACK] (0x06) 10:58:26.952 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 99 target value: 99 duration: [Duration: unknown] 10:58:26.963 SERIAL » 0x010a00130e03700528251a89 (12 bytes) 10:58:26.963 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 26 └─[ConfigurationCCGet] parameter #: 40 10:58:26.964 CNTRLR [Node 056] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 10:58:26.965 CNTRLR [Node 056] MeterCC: doing a partial interview... 10:58:26.966 CNTRLR » [Node 056] querying meter value (type = Electric, scale = kWh)... 10:58:26.970 SERIAL « [ACK] (0x06) 10:58:26.972 SERIAL « 0x0104011301e8 (6 bytes) 10:58:26.973 SERIAL » [ACK] (0x06) 10:58:26.973 DRIVER « [RES] [SendData] was sent: true 10:58:26.988 SERIAL « 0x010700131a000003f2 (9 bytes) 10:58:26.989 SERIAL » [ACK] (0x06) 10:58:26.989 DRIVER « [REQ] [SendData] callback id: 26 transmit status: OK 10:58:26.999 SERIAL « 0x010b0004000e057006280150f4 (13 bytes) 10:58:27.002 CNTRLR [Node 014] [~] [Configuration] 40: 80 => 80 10:58:27.003 SERIAL » [ACK] (0x06) 10:58:27.004 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 80 10:58:27.009 SERIAL » 0x010a00133803320100251bd0 (12 bytes) 10:58:27.009 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 27 └─[MeterCCGet] duration: kWh 10:58:27.010 CNTRLR « [Node 014] parameter #40 has value: 80 10:58:27.010 CNTRLR » [Node 014] querying parameter #42 value... 10:58:27.016 SERIAL « [ACK] (0x06) 10:58:27.020 SERIAL « 0x0104011301e8 (6 bytes) 10:58:27.020 SERIAL » [ACK] (0x06) 10:58:27.024 DRIVER « [RES] [SendData] was sent: true 10:58:27.038 SERIAL « 0x010700131b000003f3 (9 bytes) 10:58:27.038 SERIAL » [ACK] (0x06) 10:58:27.039 DRIVER « [REQ] [SendData] callback id: 27 transmit status: OK 10:58:27.093 SERIAL « 0x0114000400380e320221440000000900000000000085 (22 bytes) 10:58:27.094 CNTRLR [Node 056] [~] [Meter] value[65537]: 0.09 => 0.09 [Endpoint 0] 10:58:27.094 CNTRLR [Node 056] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 10:58:27.095 SERIAL » [ACK] (0x06) 10:58:27.096 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 0.09 time delta: 0 seconds 10:58:27.100 SERIAL » 0x010a00130e0370052a251c8d (12 bytes) 10:58:27.101 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 28 └─[ConfigurationCCGet] parameter #: 42 10:58:27.102 CNTRLR » [Node 056] querying meter value (type = Electric, scale = W)... 10:58:27.126 SERIAL « [ACK] (0x06) 10:58:27.129 SERIAL « 0x0104011301e8 (6 bytes) 10:58:27.130 SERIAL » [ACK] (0x06) 10:58:27.131 DRIVER « [RES] [SendData] was sent: true 10:58:27.137 SERIAL « 0x010700131c000002f5 (9 bytes) 10:58:27.138 SERIAL » [ACK] (0x06) 10:58:27.138 DRIVER « [REQ] [SendData] callback id: 28 transmit status: OK 10:58:27.157 SERIAL « 0x010b0004000e0570062a010fa9 (13 bytes) 10:58:27.166 CNTRLR [Node 014] [~] [Configuration] 42: 15 => 15 10:58:27.168 SERIAL » [ACK] (0x06) 10:58:27.170 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 15 10:58:27.179 SERIAL » 0x010a00133803320110251dc6 (12 bytes) 10:58:27.180 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 29 └─[MeterCCGet] duration: W 10:58:27.180 CNTRLR « [Node 014] parameter #42 has value: 15 10:58:27.181 CNTRLR » [Node 014] querying parameter #43 value... 10:58:27.193 SERIAL « [ACK] (0x06) 10:58:27.195 SERIAL « 0x0104011301e8 (6 bytes) 10:58:27.196 SERIAL » [ACK] (0x06) 10:58:27.198 DRIVER « [RES] [SendData] was sent: true 10:58:27.213 SERIAL « 0x010700131d000003f5 (9 bytes) 10:58:27.215 SERIAL » [ACK] (0x06) 10:58:27.219 DRIVER « [REQ] [SendData] callback id: 29 transmit status: OK 10:58:27.261 SERIAL « 0x0110000400380a32022132000000000000fa (18 bytes) 10:58:27.263 CNTRLR [Node 056] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 10:58:27.264 CNTRLR [Node 056] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 10:58:27.264 SERIAL » [ACK] (0x06) 10:58:27.265 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 10:58:27.272 SERIAL » 0x010a00130e0370052b251e8e (12 bytes) 10:58:27.273 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 30 └─[ConfigurationCCGet] parameter #: 43 10:58:27.274 CNTRLR [Node 056] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 10:58:27.275 CNTRLR [Node 056] ConfigurationCC: Loading configuration parameters from device confi g 10:58:27.279 CNTRLR [Node 056] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 10:58:27.281 CNTRLR [Node 056] [Configuration] 20: metadata updated 10:58:27.283 CNTRLR [Node 056] [Configuration] 24: metadata updated 10:58:27.284 CNTRLR [Node 056] [Configuration] 25: metadata updated 10:58:27.286 CNTRLR [Node 056] [Configuration] 60: metadata updated 10:58:27.288 CNTRLR [Node 056] [Configuration] 61: metadata updated 10:58:27.289 CNTRLR [Node 056] [Configuration] 62: metadata updated 10:58:27.291 CNTRLR [Node 056] [Configuration] 65: metadata updated 10:58:27.293 CNTRLR [Node 056] [Configuration] 66: metadata updated 10:58:27.294 CNTRLR [Node 056] [Configuration] 150: metadata updated 10:58:27.296 CNTRLR [Node 056] [Configuration] 151: metadata updated 10:58:27.297 CNTRLR [Node 056] [Configuration] 152: metadata updated 10:58:27.299 CNTRLR [Node 056] [Configuration] 153: metadata updated 10:58:27.301 CNTRLR [Node 056] [Configuration] 154: metadata updated 10:58:27.302 CNTRLR [Node 056] [Configuration] 155: metadata updated 10:58:27.304 CNTRLR [Node 056] [Configuration] 156: metadata updated 10:58:27.305 CNTRLR [Node 056] [Configuration] 157: metadata updated 10:58:27.307 CNTRLR [Node 056] [Configuration] 40[1]: metadata updated 10:58:27.309 CNTRLR [Node 056] [Configuration] 40[2]: metadata updated 10:58:27.310 CNTRLR [Node 056] [Configuration] 40[4]: metadata updated 10:58:27.312 CNTRLR [Node 056] [Configuration] 40[8]: metadata updated 10:58:27.313 CNTRLR [Node 056] [Configuration] 41[1]: metadata updated 10:58:27.315 CNTRLR [Node 056] [Configuration] 41[2]: metadata updated 10:58:27.316 CNTRLR [Node 056] [Configuration] 41[4]: metadata updated 10:58:27.318 CNTRLR [Node 056] [Configuration] 41[8]: metadata updated 10:58:27.319 CNTRLR [Node 056] [Configuration] 30[255]: metadata updated 10:58:27.321 CNTRLR [Node 056] [Configuration] 30[65280]: metadata updated 10:58:27.323 CNTRLR [Node 056] [Configuration] 30[16711680]: metadata updated 10:58:27.324 CNTRLR [Node 056] [Configuration] 30[4278190080]: metadata updated 10:58:27.326 CNTRLR [Node 056] [Configuration] 31[255]: metadata updated 10:58:27.327 CNTRLR [Node 056] [Configuration] 31[65280]: metadata updated 10:58:27.329 CNTRLR [Node 056] [Configuration] 31[16711680]: metadata updated 10:58:27.330 CNTRLR [Node 056] [Configuration] 31[4278190080]: metadata updated 10:58:27.332 CNTRLR [Node 056] [Configuration] 32[255]: metadata updated 10:58:27.335 CNTRLR [Node 056] [Configuration] 32[65280]: metadata updated 10:58:27.336 CNTRLR [Node 056] [Configuration] 32[16711680]: metadata updated 10:58:27.338 CNTRLR [Node 056] [Configuration] 32[4278190080]: metadata updated 10:58:27.340 CNTRLR [Node 056] [Configuration] 33[255]: metadata updated 10:58:27.344 CNTRLR [Node 056] [Configuration] 33[65280]: metadata updated 10:58:27.346 CNTRLR [Node 056] [Configuration] 33[16711680]: metadata updated 10:58:27.347 CNTRLR [Node 056] [Configuration] 33[4278190080]: metadata updated 10:58:27.349 CNTRLR [Node 056] [Configuration] 34[255]: metadata updated 10:58:27.350 CNTRLR [Node 056] [Configuration] 34[65280]: metadata updated 10:58:27.352 CNTRLR [Node 056] [Configuration] 34[16711680]: metadata updated 10:58:27.353 CNTRLR [Node 056] [Configuration] 34[4278190080]: metadata updated 10:58:27.355 CNTRLR [Node 056] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 10:58:27.355 CNTRLR » [Node 056] querying parameter #20 value... 10:58:27.372 SERIAL « [ACK] (0x06) 10:58:27.373 SERIAL « 0x0104011301e8 (6 bytes) 10:58:27.374 SERIAL » [ACK] (0x06) 10:58:27.378 DRIVER « [RES] [SendData] was sent: true 10:58:27.381 SERIAL « 0x010700131e000003f6 (9 bytes) 10:58:27.381 SERIAL » [ACK] (0x06) 10:58:27.383 DRIVER « [REQ] [SendData] callback id: 30 transmit status: OK 10:58:27.387 SERIAL « 0x010b0004000e0570062b011eb9 (13 bytes) 10:58:27.392 CNTRLR [Node 014] [~] [Configuration] 43: 30 => 30 10:58:27.393 SERIAL » [ACK] (0x06) 10:58:27.412 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 30 10:58:27.423 SERIAL » 0x010a00133803700514251f86 (12 bytes) 10:58:27.424 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 31 └─[ConfigurationCCGet] parameter #: 20 10:58:27.424 CNTRLR « [Node 014] parameter #43 has value: 30 10:58:27.425 CNTRLR » [Node 014] querying parameter #45 value... 10:58:27.459 SERIAL « [ACK] (0x06) 10:58:27.461 SERIAL « 0x0104011301e8 (6 bytes) 10:58:27.462 SERIAL » [ACK] (0x06) 10:58:27.486 DRIVER « [RES] [SendData] was sent: true 10:58:27.501 SERIAL « 0x010700131f000003f7 (9 bytes) 10:58:27.503 SERIAL » [ACK] (0x06) 10:58:27.521 DRIVER « [REQ] [SendData] callback id: 31 transmit status: OK 10:58:27.547 SERIAL « 0x010b00040038057006140100ae (13 bytes) 10:58:27.551 CNTRLR [Node 056] [~] [Configuration] 20: 0 => 0 10:58:27.552 SERIAL » [ACK] (0x06) 10:58:27.564 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 0 10:58:27.571 SERIAL » 0x010a00130e0370052d2520b6 (12 bytes) 10:58:27.571 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 32 └─[ConfigurationCCGet] parameter #: 45 10:58:27.572 CNTRLR « [Node 056] parameter #20 has value: 0 10:58:27.572 CNTRLR » [Node 056] querying parameter #24 value... 10:58:27.582 SERIAL « [ACK] (0x06) 10:58:27.584 SERIAL « 0x0104011301e8 (6 bytes) 10:58:27.584 SERIAL » [ACK] (0x06) 10:58:27.586 DRIVER « [RES] [SendData] was sent: true 10:58:27.597 SERIAL « 0x0107001320000002c9 (9 bytes) 10:58:27.597 SERIAL » [ACK] (0x06) 10:58:27.598 DRIVER « [REQ] [SendData] callback id: 32 transmit status: OK 10:58:27.608 SERIAL « 0x010b0004000e0570062d010aab (13 bytes) 10:58:27.610 CNTRLR [Node 014] [~] [Configuration] 45: 10 => 10 10:58:27.611 SERIAL » [ACK] (0x06) 10:58:27.612 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 45 value size: 1 value: 10 10:58:27.616 SERIAL » 0x010a001338037005182521b4 (12 bytes) 10:58:27.617 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 33 └─[ConfigurationCCGet] parameter #: 24 10:58:27.617 CNTRLR « [Node 014] parameter #45 has value: 10 10:58:27.618 CNTRLR » [Node 014] querying parameter #47 value... 10:58:27.626 SERIAL « [ACK] (0x06) 10:58:27.628 SERIAL « 0x0104011301e8 (6 bytes) 10:58:27.628 SERIAL » [ACK] (0x06) 10:58:27.630 DRIVER « [RES] [SendData] was sent: true 10:58:27.646 SERIAL « 0x0107001321000002c8 (9 bytes) 10:58:27.646 SERIAL » [ACK] (0x06) 10:58:27.647 DRIVER « [REQ] [SendData] callback id: 33 transmit status: OK 10:58:27.664 SERIAL « 0x010b00040038057006180100a2 (13 bytes) 10:58:27.666 CNTRLR [Node 056] [~] [Configuration] 24: 0 => 0 10:58:27.667 SERIAL » [ACK] (0x06) 10:58:27.668 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 24 value size: 1 value: 0 10:58:27.673 SERIAL » 0x010a00130e0370052f2522b6 (12 bytes) 10:58:27.673 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 34 └─[ConfigurationCCGet] parameter #: 47 10:58:27.674 CNTRLR « [Node 056] parameter #24 has value: 0 10:58:27.674 CNTRLR » [Node 056] querying parameter #25 value... 10:58:27.678 SERIAL « [ACK] (0x06) 10:58:27.683 SERIAL « 0x0104011301e8 (6 bytes) 10:58:27.683 SERIAL » [ACK] (0x06) 10:58:27.685 DRIVER « [RES] [SendData] was sent: true 10:58:27.702 SERIAL « 0x0107001322000003ca (9 bytes) 10:58:27.702 SERIAL » [ACK] (0x06) 10:58:27.703 DRIVER « [REQ] [SendData] callback id: 34 transmit status: OK 10:58:27.709 SERIAL « 0x010c0004000e0670062f020e10ba (14 bytes) 10:58:27.712 CNTRLR [Node 014] [~] [Configuration] 47: 3600 => 3600 10:58:27.713 SERIAL » [ACK] (0x06) 10:58:27.714 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 47 value size: 2 value: 3600 10:58:27.719 SERIAL » 0x010a001338037005192523b7 (12 bytes) 10:58:27.720 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 35 └─[ConfigurationCCGet] parameter #: 25 10:58:27.720 CNTRLR « [Node 014] parameter #47 has value: 3600 10:58:27.724 CNTRLR » [Node 014] querying parameter #49 value... 10:58:27.728 SERIAL « [ACK] (0x06) 10:58:27.730 SERIAL « 0x0104011301e8 (6 bytes) 10:58:27.730 SERIAL » [ACK] (0x06) 10:58:27.731 DRIVER « [RES] [SendData] was sent: true 10:58:27.749 SERIAL « 0x0107001323000003cb (9 bytes) 10:58:27.749 SERIAL » [ACK] (0x06) 10:58:27.750 DRIVER « [REQ] [SendData] callback id: 35 transmit status: OK 10:58:27.767 SERIAL « 0x010b00040038057006190100a3 (13 bytes) 10:58:27.769 CNTRLR [Node 056] [~] [Configuration] 25: 0 => 0 10:58:27.770 SERIAL » [ACK] (0x06) 10:58:27.771 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 25 value size: 1 value: 0 10:58:27.776 SERIAL » 0x010a00130e037005312524ae (12 bytes) 10:58:27.776 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 36 └─[ConfigurationCCGet] parameter #: 49 10:58:27.777 CNTRLR « [Node 056] parameter #25 has value: 0 10:58:27.777 CNTRLR » [Node 056] querying parameter #60 value... 10:58:27.781 SERIAL « [ACK] (0x06) 10:58:27.791 SERIAL « 0x0104011301e8 (6 bytes) 10:58:27.791 SERIAL » [ACK] (0x06) 10:58:27.793 DRIVER « [RES] [SendData] was sent: true 10:58:27.802 SERIAL « 0x0107001324000002cd (9 bytes) 10:58:27.803 SERIAL » [ACK] (0x06) 10:58:27.804 DRIVER « [REQ] [SendData] callback id: 36 transmit status: OK 10:58:27.812 SERIAL « 0x010b0004000e057006310100bd (13 bytes) 10:58:27.815 CNTRLR [Node 014] [~] [Configuration] 49: 0 => 0 10:58:27.816 SERIAL » [ACK] (0x06) 10:58:27.817 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 49 value size: 1 value: 0 10:58:27.823 SERIAL » 0x010a0013380370053c252594 (12 bytes) 10:58:27.824 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 37 └─[ConfigurationCCGet] parameter #: 60 10:58:27.824 CNTRLR « [Node 014] parameter #49 has value: 0 10:58:27.824 CNTRLR » [Node 014] querying parameter #50 value... 10:58:27.828 SERIAL « [ACK] (0x06) 10:58:27.832 SERIAL « 0x0104011301e8 (6 bytes) 10:58:27.832 SERIAL » [ACK] (0x06) 10:58:27.834 DRIVER « [RES] [SendData] was sent: true 10:58:27.852 SERIAL « 0x0107001325000003cd (9 bytes) 10:58:27.852 SERIAL » [ACK] (0x06) 10:58:27.853 DRIVER « [REQ] [SendData] callback id: 37 transmit status: OK 10:58:27.871 SERIAL « 0x010b000400380570063c010086 (13 bytes) 10:58:27.873 CNTRLR [Node 056] [~] [Configuration] 60: 0 => 0 10:58:27.874 SERIAL » [ACK] (0x06) 10:58:27.875 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 1 value: 0 10:58:27.879 SERIAL » 0x010a00130e037005322526af (12 bytes) 10:58:27.880 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 38 └─[ConfigurationCCGet] parameter #: 50 10:58:27.880 CNTRLR « [Node 056] parameter #60 has value: 0 10:58:27.881 CNTRLR » [Node 056] querying parameter #61 value... 10:58:27.885 SERIAL « [ACK] (0x06) 10:58:27.888 SERIAL « 0x0104011301e8 (6 bytes) 10:58:27.889 SERIAL » [ACK] (0x06) 10:58:27.890 DRIVER « [RES] [SendData] was sent: true 10:58:27.905 SERIAL « 0x0107001326000002cf (9 bytes) 10:58:27.905 SERIAL » [ACK] (0x06) 10:58:27.906 DRIVER « [REQ] [SendData] callback id: 38 transmit status: OK 10:58:27.917 SERIAL « 0x010c0004000e0670063202012c94 (14 bytes) 10:58:27.922 CNTRLR [Node 014] [~] [Configuration] 50: 300 => 300 10:58:27.924 SERIAL » [ACK] (0x06) 10:58:27.925 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 2 value: 300 10:58:27.930 SERIAL » 0x010a0013380370053d252797 (12 bytes) 10:58:27.930 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[ConfigurationCCGet] parameter #: 61 10:58:27.931 CNTRLR « [Node 014] parameter #50 has value: 300 10:58:27.931 CNTRLR » [Node 014] querying parameter #51 value... 10:58:27.935 SERIAL « [ACK] (0x06) 10:58:27.938 SERIAL « 0x0104011301e8 (6 bytes) 10:58:27.939 SERIAL » [ACK] (0x06) 10:58:27.940 DRIVER « [RES] [SendData] was sent: true 10:58:27.959 SERIAL « 0x0107001327000003cf (9 bytes) 10:58:27.960 SERIAL » [ACK] (0x06) 10:58:27.961 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 10:58:27.978 SERIAL « 0x010c000400380670063d02000f8f (14 bytes) 10:58:27.980 CNTRLR [Node 056] [~] [Configuration] 61: 15 => 15 10:58:27.981 SERIAL » [ACK] (0x06) 10:58:27.982 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 61 value size: 2 value: 15 10:58:27.987 SERIAL » 0x010a00130e037005332528a0 (12 bytes) 10:58:27.987 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 40 └─[ConfigurationCCGet] parameter #: 51 10:58:27.988 CNTRLR « [Node 056] parameter #61 has value: 15 10:58:27.988 CNTRLR » [Node 056] querying parameter #62 value... 10:58:27.994 SERIAL « [ACK] (0x06) 10:58:27.996 SERIAL « 0x0104011301e8 (6 bytes) 10:58:27.997 SERIAL » [ACK] (0x06) 10:58:27.998 DRIVER « [RES] [SendData] was sent: true 10:58:28.012 SERIAL « 0x0107001328000002c1 (9 bytes) 10:58:28.013 SERIAL » [ACK] (0x06) 10:58:28.017 DRIVER « [REQ] [SendData] callback id: 40 transmit status: OK 10:58:28.023 SERIAL « 0x010c0004000e067006330201f44d (14 bytes) 10:58:28.026 CNTRLR [Node 014] [~] [Configuration] 51: 500 => 500 10:58:28.027 SERIAL » [ACK] (0x06) 10:58:28.028 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 51 value size: 2 value: 500 10:58:28.037 SERIAL » 0x010a0013380370053e25299a (12 bytes) 10:58:28.038 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 41 └─[ConfigurationCCGet] parameter #: 62 10:58:28.038 CNTRLR « [Node 014] parameter #51 has value: 500 10:58:28.038 CNTRLR » [Node 014] querying parameter #52 value... 10:58:28.043 SERIAL « [ACK] (0x06) 10:58:28.046 SERIAL « 0x0104011301e8 (6 bytes) 10:58:28.046 SERIAL » [ACK] (0x06) 10:58:28.047 DRIVER « [RES] [SendData] was sent: true 10:58:28.066 SERIAL « 0x0107001329000002c0 (9 bytes) 10:58:28.067 SERIAL » [ACK] (0x06) 10:58:28.068 DRIVER « [REQ] [SendData] callback id: 41 transmit status: OK 10:58:28.085 SERIAL « 0x010c000400380670063e020e109d (14 bytes) 10:58:28.088 CNTRLR [Node 056] [~] [Configuration] 62: 3600 => 3600 10:58:28.089 SERIAL » [ACK] (0x06) 10:58:28.090 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 62 value size: 2 value: 3600 10:58:28.095 SERIAL » 0x010a00130e03700534252aa5 (12 bytes) 10:58:28.096 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 42 └─[ConfigurationCCGet] parameter #: 52 10:58:28.096 CNTRLR « [Node 056] parameter #62 has value: 3600 10:58:28.096 CNTRLR » [Node 056] querying parameter #65 value... 10:58:28.101 SERIAL « [ACK] (0x06) 10:58:28.103 SERIAL « 0x0104011301e8 (6 bytes) 10:58:28.104 SERIAL » [ACK] (0x06) 10:58:28.107 DRIVER « [RES] [SendData] was sent: true 10:58:28.120 SERIAL « 0x010700132a000002c3 (9 bytes) 10:58:28.121 SERIAL » [ACK] (0x06) 10:58:28.122 DRIVER « [REQ] [SendData] callback id: 42 transmit status: OK 10:58:28.134 SERIAL « 0x010b0004000e057006340106be (13 bytes) 10:58:28.136 CNTRLR [Node 014] [~] [Configuration] 52: 6 => 6 10:58:28.138 SERIAL » [ACK] (0x06) 10:58:28.139 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 52 value size: 1 value: 6 10:58:28.145 SERIAL » 0x010a00133803700541252be7 (12 bytes) 10:58:28.146 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 43 └─[ConfigurationCCGet] parameter #: 65 10:58:28.146 CNTRLR « [Node 014] parameter #52 has value: 6 10:58:28.147 CNTRLR » [Node 014] querying parameter #60 value... 10:58:28.152 SERIAL « [ACK] (0x06) 10:58:28.161 SERIAL « 0x0104011301e8 (6 bytes) 10:58:28.162 SERIAL » [ACK] (0x06) 10:58:28.164 DRIVER « [RES] [SendData] was sent: true 10:58:28.175 SERIAL « 0x010700132b000002c2 (9 bytes) 10:58:28.176 SERIAL » [ACK] (0x06) 10:58:28.177 DRIVER « [REQ] [SendData] callback id: 43 transmit status: OK 10:58:28.197 SERIAL « 0x010c000400380670064102000af6 (14 bytes) 10:58:28.205 CNTRLR [Node 056] [~] [Configuration] 65: 10 => 10 10:58:28.211 SERIAL » [ACK] (0x06) 10:58:28.212 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 65 value size: 2 value: 10 10:58:28.218 SERIAL » 0x010a00130e0370053c252cab (12 bytes) 10:58:28.218 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 44 └─[ConfigurationCCGet] parameter #: 60 10:58:28.219 CNTRLR « [Node 056] parameter #65 has value: 10 10:58:28.219 CNTRLR » [Node 056] querying parameter #66 value... 10:58:28.226 SERIAL « [ACK] (0x06) 10:58:28.228 SERIAL « 0x0104011301e8 (6 bytes) 10:58:28.229 SERIAL » [ACK] (0x06) 10:58:28.231 DRIVER « [RES] [SendData] was sent: true 10:58:28.250 SERIAL « 0x010700132c000002c5 (9 bytes) 10:58:28.251 SERIAL » [ACK] (0x06) 10:58:28.252 DRIVER « [REQ] [SendData] callback id: 44 transmit status: OK 10:58:28.257 SERIAL « 0x010c0004000e0670063c0261a87e (14 bytes) 10:58:28.259 CNTRLR [Node 014] [~] [Configuration] 60: 25000 => 25000 10:58:28.260 SERIAL » [ACK] (0x06) 10:58:28.262 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 2 value: 25000 10:58:28.266 SERIAL » 0x010a00133803700542252de2 (12 bytes) 10:58:28.267 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 45 └─[ConfigurationCCGet] parameter #: 66 10:58:28.267 CNTRLR « [Node 014] parameter #60 has value: 25000 10:58:28.267 CNTRLR » [Node 014] querying parameter #61 value... 10:58:28.276 SERIAL « [ACK] (0x06) 10:58:28.279 SERIAL « 0x0104011301e8 (6 bytes) 10:58:28.280 SERIAL » [ACK] (0x06) 10:58:28.283 DRIVER « [RES] [SendData] was sent: true 10:58:28.295 SERIAL « 0x010700132d000002c4 (9 bytes) 10:58:28.296 SERIAL » [ACK] (0x06) 10:58:28.297 DRIVER « [REQ] [SendData] callback id: 45 transmit status: OK 10:58:28.314 SERIAL « 0x010c0004003806700642020e10e1 (14 bytes) 10:58:28.316 CNTRLR [Node 056] [~] [Configuration] 66: 3600 => 3600 10:58:28.321 SERIAL » [ACK] (0x06) 10:58:28.322 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 66 value size: 2 value: 3600 10:58:28.327 SERIAL » 0x010a00130e0370053d252ea8 (12 bytes) 10:58:28.327 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 46 └─[ConfigurationCCGet] parameter #: 61 10:58:28.328 CNTRLR « [Node 056] parameter #66 has value: 3600 10:58:28.328 CNTRLR » [Node 056] querying parameter #150 value... 10:58:28.333 SERIAL « [ACK] (0x06) 10:58:28.336 SERIAL « 0x0104011301e8 (6 bytes) 10:58:28.336 SERIAL » [ACK] (0x06) 10:58:28.338 DRIVER « [RES] [SendData] was sent: true 10:58:28.352 SERIAL « 0x010700132e000002c7 (9 bytes) 10:58:28.353 SERIAL » [ACK] (0x06) 10:58:28.354 DRIVER « [REQ] [SendData] callback id: 46 transmit status: OK 10:58:28.363 SERIAL « 0x010b0004000e0570063d0101b0 (13 bytes) 10:58:28.365 CNTRLR [Node 014] [~] [Configuration] 61: 1 => 1 10:58:28.367 SERIAL » [ACK] (0x06) 10:58:28.368 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 61 value size: 1 value: 1 10:58:28.374 SERIAL » 0x010a00133803700596252f34 (12 bytes) 10:58:28.374 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 47 └─[ConfigurationCCGet] parameter #: 150 10:58:28.375 CNTRLR « [Node 014] parameter #61 has value: 1 10:58:28.375 CNTRLR » [Node 014] querying parameter #62 value... 10:58:28.380 SERIAL « [ACK] (0x06) 10:58:28.383 SERIAL « 0x0104011301e8 (6 bytes) 10:58:28.383 SERIAL » [ACK] (0x06) 10:58:28.386 DRIVER « [RES] [SendData] was sent: true 10:58:28.403 SERIAL « 0x010700132f000003c7 (9 bytes) 10:58:28.404 SERIAL » [ACK] (0x06) 10:58:28.404 DRIVER « [REQ] [SendData] callback id: 47 transmit status: OK 10:58:28.421 SERIAL « 0x010b000400380570069601012d (13 bytes) 10:58:28.423 CNTRLR [Node 056] [~] [Configuration] 150: 1 => 1 10:58:28.425 SERIAL » [ACK] (0x06) 10:58:28.425 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 150 value size: 1 value: 1 10:58:28.429 SERIAL » 0x010a00130e0370053e2530b5 (12 bytes) 10:58:28.430 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 48 └─[ConfigurationCCGet] parameter #: 62 10:58:28.430 CNTRLR « [Node 056] parameter #150 has value: 1 10:58:28.431 CNTRLR » [Node 056] querying parameter #151 value... 10:58:28.437 SERIAL « [ACK] (0x06) 10:58:28.440 SERIAL « 0x0104011301e8 (6 bytes) 10:58:28.440 SERIAL » [ACK] (0x06) 10:58:28.441 DRIVER « [RES] [SendData] was sent: true 10:58:28.455 SERIAL « 0x0107001330000002d9 (9 bytes) 10:58:28.455 SERIAL » [ACK] (0x06) 10:58:28.456 DRIVER « [REQ] [SendData] callback id: 48 transmit status: OK 10:58:28.466 SERIAL « 0x010b0004000e0570063e0108ba (13 bytes) 10:58:28.468 CNTRLR [Node 014] [~] [Configuration] 62: 8 => 8 10:58:28.469 SERIAL » [ACK] (0x06) 10:58:28.470 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 62 value size: 1 value: 8 10:58:28.474 SERIAL » 0x010a0013380370059725312b (12 bytes) 10:58:28.474 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 49 └─[ConfigurationCCGet] parameter #: 151 10:58:28.474 CNTRLR « [Node 014] parameter #62 has value: 8 10:58:28.475 CNTRLR » [Node 014] querying parameter #63 value... 10:58:28.478 SERIAL « [ACK] (0x06) 10:58:28.483 SERIAL « 0x0104011301e8 (6 bytes) 10:58:28.484 SERIAL » [ACK] (0x06) 10:58:28.485 DRIVER « [RES] [SendData] was sent: true 10:58:28.503 SERIAL « 0x0107001331000003d9 (9 bytes) 10:58:28.503 SERIAL » [ACK] (0x06) 10:58:28.504 DRIVER « [REQ] [SendData] callback id: 49 transmit status: OK 10:58:28.521 SERIAL « 0x010b000400380570069701012c (13 bytes) 10:58:28.523 CNTRLR [Node 056] [~] [Configuration] 151: 1 => 1 10:58:28.524 SERIAL » [ACK] (0x06) 10:58:28.525 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 151 value size: 1 value: 1 10:58:28.529 SERIAL » 0x010a00130e0370053f2532b6 (12 bytes) 10:58:28.530 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 50 └─[ConfigurationCCGet] parameter #: 63 10:58:28.530 CNTRLR « [Node 056] parameter #151 has value: 1 10:58:28.530 CNTRLR » [Node 056] querying parameter #152 value... 10:58:28.534 SERIAL « [ACK] (0x06) 10:58:28.539 SERIAL « 0x0104011301e8 (6 bytes) 10:58:28.539 SERIAL » [ACK] (0x06) 10:58:28.541 DRIVER « [RES] [SendData] was sent: true 10:58:28.555 SERIAL « 0x0107001332000002db (9 bytes) 10:58:28.555 SERIAL » [ACK] (0x06) 10:58:28.556 DRIVER « [REQ] [SendData] callback id: 50 transmit status: OK 10:58:28.566 SERIAL « 0x010b0004000e0570063f0101b2 (13 bytes) 10:58:28.568 CNTRLR [Node 014] [~] [Configuration] 63: 1 => 1 10:58:28.569 SERIAL » [ACK] (0x06) 10:58:28.570 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 63 value size: 1 value: 1 10:58:28.574 SERIAL » 0x010a00133803700598253326 (12 bytes) 10:58:28.574 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 51 └─[ConfigurationCCGet] parameter #: 152 10:58:28.575 CNTRLR « [Node 014] parameter #63 has value: 1 10:58:28.575 CNTRLR » [Node 014] querying parameter #70 value... 10:58:28.588 SERIAL « [ACK] (0x06) 10:58:28.591 SERIAL « 0x0104011301e8 (6 bytes) 10:58:28.592 SERIAL » [ACK] (0x06) 10:58:28.608 DRIVER « [RES] [SendData] was sent: true 10:58:28.616 SERIAL « 0x0107001333000003db (9 bytes) 10:58:28.616 SERIAL » [ACK] (0x06) 10:58:28.618 DRIVER « [REQ] [SendData] callback id: 51 transmit status: OK 10:58:28.631 SERIAL « 0x010e00040038087006980400000096b9 (16 bytes) 10:58:28.634 CNTRLR [Node 056] [~] [Configuration] 152: 150 => 150 10:58:28.636 SERIAL » [ACK] (0x06) 10:58:28.638 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 152 value size: 4 value: 150 10:58:28.646 SERIAL » 0x010a00130e037005462534c9 (12 bytes) 10:58:28.646 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 52 └─[ConfigurationCCGet] parameter #: 70 10:58:28.647 CNTRLR « [Node 056] parameter #152 has value: 150 10:58:28.647 CNTRLR » [Node 056] querying parameter #153 value... 10:58:28.653 SERIAL « [ACK] (0x06) 10:58:28.655 SERIAL « 0x0104011301e8 (6 bytes) 10:58:28.656 SERIAL » [ACK] (0x06) 10:58:28.658 DRIVER « [RES] [SendData] was sent: true 10:58:28.671 SERIAL « 0x0107001334000002dd (9 bytes) 10:58:28.672 SERIAL » [ACK] (0x06) 10:58:28.673 DRIVER « [REQ] [SendData] callback id: 52 transmit status: OK 10:58:28.682 SERIAL « 0x010c0004000e0670064602ffffcd (14 bytes) 10:58:28.684 CNTRLR [Node 014] [~] [Configuration] 70: 65535 => 65535 10:58:28.688 SERIAL » [ACK] (0x06) 10:58:28.689 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 70 value size: 2 value: 65535 10:58:28.694 SERIAL » 0x010a00133803700599253521 (12 bytes) 10:58:28.694 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 53 └─[ConfigurationCCGet] parameter #: 153 10:58:28.695 CNTRLR « [Node 014] parameter #70 has value: 65535 10:58:28.695 CNTRLR [Node 014] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 10:58:28.706 SERIAL « [ACK] (0x06) 10:58:28.710 SERIAL « 0x0104011301e8 (6 bytes) 10:58:28.711 SERIAL » [ACK] (0x06) 10:58:28.712 DRIVER « [RES] [SendData] was sent: true 10:58:28.716 CNTRLR [Node 014] MultiChannelAssociationCC: doing a partial interview... 10:58:28.717 CNTRLR » [Node 014] querying multi channel association group #1... 10:58:28.734 SERIAL « 0x0107001335000003dd (9 bytes) 10:58:28.735 SERIAL » [ACK] (0x06) 10:58:28.736 DRIVER « [REQ] [SendData] callback id: 53 transmit status: OK 10:58:28.741 SERIAL « 0x010b0004003805700699010122 (13 bytes) 10:58:28.744 CNTRLR [Node 056] [~] [Configuration] 153: 1 => 1 10:58:28.745 SERIAL » [ACK] (0x06) 10:58:28.746 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 153 value size: 1 value: 1 10:58:28.750 SERIAL » 0x010800130f01002536f9 (10 bytes) 10:58:28.751 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 54 └─[NoOperationCC] 10:58:28.751 CNTRLR « [Node 056] parameter #153 has value: 1 10:58:28.751 CNTRLR » [Node 056] querying parameter #154 value... 10:58:28.757 SERIAL « [ACK] (0x06) 10:58:28.763 SERIAL « 0x0104011301e8 (6 bytes) 10:58:28.763 SERIAL » [ACK] (0x06) 10:58:28.765 DRIVER « [RES] [SendData] was sent: true 10:58:35.730 SERIAL « 0x01070013360102ba64 (9 bytes) 10:58:35.731 SERIAL » [ACK] (0x06) 10:58:35.731 DRIVER « [REQ] [SendData] callback id: 54 transmit status: NoAck 10:58:35.737 SERIAL » 0x010a0013380370059a253720 (12 bytes) 10:58:35.737 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 55 └─[ConfigurationCCGet] parameter #: 154 10:58:35.737 CNTRLR [Node 015] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 10:58:35.738 CNTRLR [Node 015] The node is asleep. 10:58:35.739 CNTRLR [Node 015] ping failed: Failed to send the command after 1 attempts (Status No Ack) 10:58:35.740 CNTRLR » [Node 015] querying node info... 10:58:35.743 SERIAL « [ACK] (0x06) 10:58:35.749 SERIAL « 0x0104011301e8 (6 bytes) 10:58:35.749 SERIAL » [ACK] (0x06) 10:58:35.750 DRIVER « [RES] [SendData] was sent: true 10:58:35.767 SERIAL « 0x0107001337000003df (9 bytes) 10:58:35.768 SERIAL » [ACK] (0x06) 10:58:35.768 DRIVER « [REQ] [SendData] callback id: 55 transmit status: OK 10:58:35.786 SERIAL « 0x010c000400380670069a02000a2d (14 bytes) 10:58:35.788 CNTRLR [Node 056] [~] [Configuration] 154: 10 => 10 10:58:35.789 SERIAL » [ACK] (0x06) 10:58:35.790 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 154 value size: 2 value: 10 10:58:35.794 SERIAL » 0x010800131001002538e8 (10 bytes) 10:58:35.794 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 56 └─[NoOperationCC] 10:58:35.795 CNTRLR « [Node 056] parameter #154 has value: 10 10:58:35.795 CNTRLR » [Node 056] querying parameter #155 value... 10:58:35.799 SERIAL « [ACK] (0x06) 10:58:35.804 SERIAL « 0x0104011301e8 (6 bytes) 10:58:35.804 SERIAL » [ACK] (0x06) 10:58:35.805 DRIVER « [RES] [SendData] was sent: true 10:58:43.019 SERIAL « 0x01070013380102d303 (9 bytes) 10:58:43.020 SERIAL » [ACK] (0x06) 10:58:43.021 DRIVER « [REQ] [SendData] callback id: 56 transmit status: NoAck 10:58:43.030 SERIAL » 0x010a0013380370059b25392f (12 bytes) 10:58:43.031 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 57 └─[ConfigurationCCGet] parameter #: 155 10:58:43.032 CNTRLR [Node 016] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 10:58:43.033 CNTRLR [Node 016] The node is asleep. 10:58:43.035 CNTRLR [Node 016] The node is ready to be used 10:58:43.037 CNTRLR [Node 016] ping failed: Failed to send the command after 1 attempts (Status No Ack) 10:58:43.042 CNTRLR [Node 016] ManufacturerSpecificCC: doing a partial interview... 10:58:43.043 CNTRLR [Node 016] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 10:58:43.067 SERIAL « [ACK] (0x06) 10:58:43.069 SERIAL « 0x0104011301e8 (6 bytes) 10:58:43.070 SERIAL » [ACK] (0x06) 10:58:43.072 DRIVER « [RES] [SendData] was sent: true 10:58:43.081 CNTRLR [Node 016] VersionCC: doing a partial interview... 10:58:43.081 CNTRLR [Node 016] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 10:58:43.082 CNTRLR [Node 016] trying to load device config 10:58:43.084 SERIAL « 0x0107001339000002d0 (9 bytes) 10:58:43.084 SERIAL » [ACK] (0x06) 10:58:43.086 DRIVER « [REQ] [SendData] callback id: 57 transmit status: OK 10:58:43.091 SERIAL « 0x010c000400380670069b02000a2c (14 bytes) 10:58:43.094 CNTRLR [Node 056] [~] [Configuration] 155: 10 => 10 10:58:43.095 SERIAL » [ACK] (0x06) 10:58:43.097 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 155 value size: 2 value: 10 10:58:43.108 SERIAL » 0x01080013110100253aeb (10 bytes) 10:58:43.108 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 58 └─[NoOperationCC] 10:58:43.109 CNTRLR « [Node 056] parameter #155 has value: 10 10:58:43.110 CNTRLR » [Node 056] querying parameter #156 value... 10:58:43.122 CNTRLR [Node 016] device config loaded 10:58:43.123 CNTRLR [Node 016] BatteryCC: doing a partial interview... 10:58:43.123 CNTRLR » [Node 016] querying battery status... 10:58:43.129 SERIAL « [ACK] (0x06) 10:58:43.131 SERIAL « 0x0104011301e8 (6 bytes) 10:58:43.132 SERIAL » [ACK] (0x06) 10:58:43.134 DRIVER « [RES] [SendData] was sent: true 10:58:50.683 SERIAL « 0x010700133a0102f527 (9 bytes) 10:58:50.683 SERIAL » [ACK] (0x06) 10:58:50.685 DRIVER « [REQ] [SendData] callback id: 58 transmit status: NoAck 10:58:50.698 SERIAL » 0x010a0013380370059c253b2a (12 bytes) 10:58:50.699 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 59 └─[ConfigurationCCGet] parameter #: 156 10:58:50.700 CNTRLR [Node 017] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 10:58:50.701 CNTRLR [Node 017] The node is asleep. 10:58:50.704 CNTRLR [Node 017] The node is ready to be used 10:58:50.708 CNTRLR [Node 017] ping failed: Failed to send the command after 1 attempts (Status No Ack) 10:58:50.711 CNTRLR [Node 017] ManufacturerSpecificCC: doing a partial interview... 10:58:50.712 CNTRLR [Node 017] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 10:58:50.740 SERIAL « [ACK] (0x06) 10:58:50.742 SERIAL « 0x0104011301e8 (6 bytes) 10:58:50.743 SERIAL » [ACK] (0x06) 10:58:50.748 DRIVER « [RES] [SendData] was sent: true 10:58:50.754 SERIAL « 0x010700133b000002d2 (9 bytes) 10:58:50.754 SERIAL » [ACK] (0x06) 10:58:50.756 CNTRLR [Node 017] VersionCC: doing a partial interview... 10:58:50.756 CNTRLR [Node 017] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 10:58:50.756 CNTRLR [Node 017] trying to load device config 10:58:50.758 DRIVER « [REQ] [SendData] callback id: 59 transmit status: OK 10:58:50.764 SERIAL « 0x010e000400380870069c04000006e0cd (16 bytes) 10:58:50.766 CNTRLR [Node 056] [~] [Configuration] 156: 1760 => 1760 10:58:50.767 SERIAL » [ACK] (0x06) 10:58:50.769 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 156 value size: 4 value: 1760 10:58:50.773 SERIAL » 0x01080013120100253cee (10 bytes) 10:58:50.774 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 60 └─[NoOperationCC] 10:58:50.774 CNTRLR « [Node 056] parameter #156 has value: 1760 10:58:50.775 CNTRLR » [Node 056] querying parameter #157 value... 10:58:50.868 CNTRLR [Node 017] device config loaded 10:58:50.869 CNTRLR [Node 017] BatteryCC: doing a partial interview... 10:58:50.869 CNTRLR » [Node 017] querying battery status... 10:58:50.872 SERIAL « [ACK] (0x06) 10:58:50.873 SERIAL « 0x0104011301e8 (6 bytes) 10:58:50.874 SERIAL » [ACK] (0x06) 10:58:50.876 DRIVER « [RES] [SendData] was sent: true 10:58:57.704 SERIAL « 0x010700133c0102b561 (9 bytes) 10:58:57.705 SERIAL » [ACK] (0x06) 10:58:57.708 DRIVER « [REQ] [SendData] callback id: 60 transmit status: NoAck 10:58:57.725 SERIAL » 0x01080013130100253dee (10 bytes) 10:58:57.726 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 61 └─[NoOperationCC] 10:58:57.727 CNTRLR [Node 018] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 10:58:57.729 CNTRLR [Node 018] The node is asleep. 10:58:57.732 CNTRLR [Node 018] ping failed: Failed to send the command after 1 attempts (Status No Ack) 10:58:57.733 CNTRLR » [Node 018] querying node info... 10:58:57.741 SERIAL « [ACK] (0x06) 10:58:57.744 SERIAL « 0x0104011301e8 (6 bytes) 10:58:57.755 SERIAL » [ACK] (0x06) 10:58:57.756 DRIVER « [RES] [SendData] was sent: true 10:58:57.778 SERIAL « 0x010700133d000005d3 (9 bytes) 10:58:57.779 SERIAL » [ACK] (0x06) 10:58:57.781 DRIVER « [REQ] [SendData] callback id: 61 transmit status: OK 10:58:57.796 SERIAL » 0x010a0013380370059d253e2e (12 bytes) 10:58:57.797 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 62 └─[ConfigurationCCGet] parameter #: 157 10:58:57.798 CNTRLR « [Node 019] ping successful 10:58:57.801 CNTRLR [Node 019] BinarySwitchCC: doing a partial interview... 10:58:57.801 CNTRLR » [Node 019] querying Binary Switch state... 10:58:57.812 SERIAL « [ACK] (0x06) 10:58:57.814 SERIAL « 0x0104011301e8 (6 bytes) 10:58:57.815 SERIAL » [ACK] (0x06) 10:58:57.816 DRIVER « [RES] [SendData] was sent: true 10:58:57.827 SERIAL « 0x010700133e000002d7 (9 bytes) 10:58:57.828 SERIAL » [ACK] (0x06) 10:58:57.829 DRIVER « [REQ] [SendData] callback id: 62 transmit status: OK 10:58:57.846 SERIAL « 0x010e000400380870069d040000065f73 (16 bytes) 10:58:57.849 CNTRLR [Node 056] [~] [Configuration] 157: 1631 => 1631 10:58:57.851 SERIAL » [ACK] (0x06) 10:58:57.852 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 157 value size: 4 value: 1631 10:58:57.858 SERIAL » 0x0109001313022502253fc9 (11 bytes) 10:58:57.858 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 63 └─[BinarySwitchCCGet] 10:58:57.859 CNTRLR « [Node 056] parameter #157 has value: 1631 10:58:57.859 CNTRLR » [Node 056] querying parameter #40 value... 10:58:57.865 SERIAL « [ACK] (0x06) 10:58:57.868 SERIAL « 0x0104011301e8 (6 bytes) 10:58:57.868 SERIAL » [ACK] (0x06) 10:58:57.869 DRIVER « [RES] [SendData] was sent: true 10:58:57.904 SERIAL « 0x010700133f000004d0 (9 bytes) 10:58:57.905 SERIAL » [ACK] (0x06) 10:58:57.905 DRIVER « [REQ] [SendData] callback id: 63 transmit status: OK 10:58:57.949 SERIAL « 0x01090004001303250300c4 (11 bytes) 10:58:57.950 CNTRLR [Node 019] [~] [Binary Switch] currentValue: false => false [Endpoint 0] 10:58:57.953 SERIAL » [ACK] (0x06) 10:58:57.955 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 10:58:57.959 SERIAL » 0x010a001338037005282540e5 (12 bytes) 10:58:57.960 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 64 └─[ConfigurationCCGet] parameter #: 40 10:58:57.961 CNTRLR [Node 019] The node is alive. 10:58:57.962 CNTRLR [Node 019] The node is ready to be used 10:58:57.964 CNTRLR « [Node 019] received Binary Switch state: current value: false 10:58:57.965 CNTRLR [Node 019] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 10:58:57.982 SERIAL « [ACK] (0x06) 10:58:57.988 SERIAL « 0x0104011301e8 (6 bytes) 10:58:57.988 SERIAL » [ACK] (0x06) 10:58:57.990 DRIVER « [RES] [SendData] was sent: true 10:58:57.993 CNTRLR [Node 019] Interview stage completed: CommandClasses 10:58:57.994 CNTRLR [Node 019] Interview stage completed: OverwriteConfig 10:58:57.994 CNTRLR » [Node 019] requesting node neighbors... 10:58:58.037 SERIAL « 0x0107001340000008a3 (9 bytes) 10:58:58.038 SERIAL » [ACK] (0x06) 10:58:58.038 DRIVER « [REQ] [SendData] callback id: 64 transmit status: OK 10:58:58.058 SERIAL « 0x010b0004003805700628010092 (13 bytes) 10:58:58.061 CNTRLR [Node 056] [~] [Configuration] 40[1]: 0 => 0 10:58:58.063 CNTRLR [Node 056] [~] [Configuration] 40[2]: 0 => 0 10:58:58.064 CNTRLR [Node 056] [~] [Configuration] 40[4]: 0 => 0 10:58:58.066 CNTRLR [Node 056] [~] [Configuration] 40[8]: 0 => 0 10:58:58.069 SERIAL » [ACK] (0x06) 10:58:58.070 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 0 10:58:58.074 SERIAL » 0x01070080130000006b (9 bytes) 10:58:58.075 DRIVER » [Node 019] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 10:58:58.075 CNTRLR « [Node 056] parameter #40 has value: 0 10:58:58.076 CNTRLR » [Node 056] querying parameter #41 value... 10:58:58.081 SERIAL « [ACK] (0x06) 10:58:58.083 SERIAL « 0x0120018001e05a203f00a00000000000000000000000000000000000000000000 (34 bytes) 05a 10:58:58.083 SERIAL » [ACK] (0x06) 10:58:58.084 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 14, 15, 16, 18, 20, 21, 23, 30, 33, 34, 35, 36, 37, 38, 54, 56 10:58:58.093 SERIAL » 0x010a001338037005292541e5 (12 bytes) 10:58:58.094 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 65 └─[ConfigurationCCGet] parameter #: 41 10:58:58.094 CNTRLR « [Node 019] node neighbors received: 1, 14, 15, 16, 18, 20, 21, 23, 30, 33, 3 4, 35, 36, 37, 38, 54, 56 10:58:58.094 CNTRLR [Node 019] Interview stage completed: Neighbors 10:58:58.095 CNTRLR [Node 019] Interview completed 10:58:58.104 SERIAL « [ACK] (0x06) 10:58:58.106 SERIAL « 0x0104011301e8 (6 bytes) 10:58:58.107 SERIAL » [ACK] (0x06) 10:58:58.111 DRIVER « [RES] [SendData] was sent: true 10:58:58.128 SERIAL « 0x0107001341000003a9 (9 bytes) 10:58:58.128 SERIAL » [ACK] (0x06) 10:58:58.130 DRIVER « [REQ] [SendData] callback id: 65 transmit status: OK 10:58:58.141 SERIAL « 0x010b0004003805700629010093 (13 bytes) 10:58:58.147 CNTRLR [Node 056] [~] [Configuration] 41[1]: 0 => 0 10:58:58.149 CNTRLR [Node 056] [~] [Configuration] 41[2]: 0 => 0 10:58:58.150 CNTRLR [Node 056] [~] [Configuration] 41[4]: 0 => 0 10:58:58.152 CNTRLR [Node 056] [~] [Configuration] 41[8]: 0 => 0 10:58:58.154 SERIAL » [ACK] (0x06) 10:58:58.155 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 41 value size: 1 value: 0 10:58:58.160 SERIAL » 0x01080013140100254296 (10 bytes) 10:58:58.161 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 66 └─[NoOperationCC] 10:58:58.161 CNTRLR « [Node 056] parameter #41 has value: 0 10:58:58.162 CNTRLR » [Node 056] querying parameter #30 value... 10:58:58.199 SERIAL « [ACK] (0x06) 10:58:58.205 SERIAL « 0x0104011301e8 (6 bytes) 10:58:58.205 SERIAL » [ACK] (0x06) 10:58:58.215 DRIVER « [RES] [SendData] was sent: true 10:59:10.339 SERIAL « 0x01070013420104c26e (9 bytes) 10:59:10.340 SERIAL » [ACK] (0x06) 10:59:10.341 DRIVER « [REQ] [SendData] callback id: 66 transmit status: NoAck 10:59:10.347 SERIAL » 0x01080013150100254396 (10 bytes) 10:59:10.348 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 67 └─[NoOperationCC] 10:59:10.348 CNTRLR [Node 020] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 10:59:10.349 CNTRLR [Node 020] The node is asleep. 10:59:10.351 CNTRLR [Node 020] The node is ready to be used 10:59:10.353 CNTRLR [Node 020] ping failed: Failed to send the command after 1 attempts (Status No Ack) 10:59:10.356 CNTRLR [Node 020] ManufacturerSpecificCC: doing a partial interview... 10:59:10.356 CNTRLR [Node 020] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 10:59:10.373 SERIAL « [ACK] (0x06) 10:59:10.379 SERIAL « 0x0104011301e8 (6 bytes) 10:59:10.380 SERIAL » [ACK] (0x06) 10:59:10.384 DRIVER « [RES] [SendData] was sent: true 10:59:10.387 CNTRLR [Node 020] VersionCC: doing a partial interview... 10:59:10.389 CNTRLR [Node 020] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 10:59:10.389 CNTRLR [Node 020] trying to load device config 10:59:10.406 CNTRLR [Node 020] device config loaded 10:59:10.407 CNTRLR [Node 020] BatteryCC: doing a partial interview... 10:59:10.408 CNTRLR » [Node 020] querying battery status... 10:59:10.523 SERIAL « 0x010700134300000da5 (9 bytes) 10:59:10.523 SERIAL » [ACK] (0x06) 10:59:10.525 DRIVER « [REQ] [SendData] callback id: 67 transmit status: OK 10:59:10.531 SERIAL » 0x010a0013380370051e2544d7 (12 bytes) 10:59:10.531 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 68 └─[ConfigurationCCGet] parameter #: 30 10:59:10.532 CNTRLR « [Node 021] ping successful 10:59:10.533 CNTRLR [Node 021] ManufacturerSpecificCC: doing a partial interview... 10:59:10.533 CNTRLR [Node 021] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 10:59:10.534 CNTRLR [Node 021] VersionCC: doing a partial interview... 10:59:10.534 CNTRLR [Node 021] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 10:59:10.534 CNTRLR [Node 021] trying to load device config 10:59:10.538 SERIAL « [ACK] (0x06) 10:59:10.540 SERIAL « 0x0104011301e8 (6 bytes) 10:59:10.541 SERIAL » [ACK] (0x06) 10:59:10.542 DRIVER « [RES] [SendData] was sent: true 10:59:10.552 CNTRLR [Node 021] device config loaded 10:59:10.575 SERIAL « 0x0107001344000003ac (9 bytes) 10:59:10.575 SERIAL » [ACK] (0x06) 10:59:10.577 DRIVER « [REQ] [SendData] callback id: 68 transmit status: OK 10:59:10.583 CNTRLR [Node 021] AssociationCC: doing a partial interview... 10:59:10.584 CNTRLR [Node 021] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 10:59:10.584 CNTRLR [Node 021] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 10:59:10.585 CNTRLR [Node 021] BinarySwitchCC: doing a partial interview... 10:59:10.585 CNTRLR » [Node 021] querying Binary Switch state... 10:59:10.590 SERIAL « 0x010e000400380870061e0400000000a9 (16 bytes) 10:59:10.593 CNTRLR [Node 056] [~] [Configuration] 30[255]: 0 => 0 10:59:10.595 CNTRLR [Node 056] [~] [Configuration] 30[65280]: 0 => 0 10:59:10.597 CNTRLR [Node 056] [~] [Configuration] 30[16711680]: 0 => 0 10:59:10.599 CNTRLR [Node 056] [~] [Configuration] 30[4278190080]: 0 => 0 10:59:10.600 SERIAL » [ACK] (0x06) 10:59:10.607 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 4 value: 0 10:59:10.611 SERIAL » 0x01090013150225022545b5 (11 bytes) 10:59:10.612 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 69 └─[BinarySwitchCCGet] 10:59:10.612 CNTRLR « [Node 056] parameter #30 has value: 0 10:59:10.613 CNTRLR » [Node 056] querying parameter #31 value... 10:59:10.619 SERIAL « [ACK] (0x06) 10:59:10.621 SERIAL « 0x0104011301e8 (6 bytes) 10:59:10.622 SERIAL » [ACK] (0x06) 10:59:10.626 DRIVER « [RES] [SendData] was sent: true 10:59:10.752 SERIAL « 0x010700134500000ea0 (9 bytes) 10:59:10.753 SERIAL » [ACK] (0x06) 10:59:10.754 DRIVER « [REQ] [SendData] callback id: 69 transmit status: OK 10:59:10.870 SERIAL « 0x01090004001503250300c2 (11 bytes) 10:59:10.871 CNTRLR [Node 021] [~] [Binary Switch] currentValue: true => false [Endpoint 0] 10:59:10.872 SERIAL » [ACK] (0x06) 10:59:10.873 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 10:59:10.888 SERIAL » 0x010a0013380370051f2546d4 (12 bytes) 10:59:10.888 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 70 └─[ConfigurationCCGet] parameter #: 31 10:59:10.889 CNTRLR [Node 021] The node is alive. 10:59:10.890 CNTRLR [Node 021] The node is ready to be used 10:59:10.892 CNTRLR « [Node 021] received Binary Switch state: current value: false 10:59:10.893 CNTRLR [Node 021] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 10:59:10.924 SERIAL « [ACK] (0x06) 10:59:10.927 SERIAL « 0x0104011301e8 (6 bytes) 10:59:10.927 SERIAL » [ACK] (0x06) 10:59:10.935 DRIVER « [RES] [SendData] was sent: true 10:59:10.944 CNTRLR [Node 021] MultilevelSwitchCC: doing a partial interview... 10:59:10.944 CNTRLR » [Node 021] requesting current switch state... 10:59:11.047 SERIAL « 0x010700134600000aa7 (9 bytes) 10:59:11.048 SERIAL » [ACK] (0x06) 10:59:11.051 DRIVER « [REQ] [SendData] callback id: 70 transmit status: OK 10:59:11.065 SERIAL « 0x010e000400380870061f0405ff000052 (16 bytes) 10:59:11.070 CNTRLR [Node 056] [~] [Configuration] 31[255]: 0 => 0 10:59:11.072 CNTRLR [Node 056] [~] [Configuration] 31[65280]: 0 => 0 10:59:11.074 CNTRLR [Node 056] [~] [Configuration] 31[16711680]: 255 => 255 10:59:11.076 CNTRLR [Node 056] [~] [Configuration] 31[4278190080]: 5 => 5 10:59:11.077 SERIAL » [ACK] (0x06) 10:59:11.080 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 4 value: 100597760 10:59:11.091 SERIAL » 0x01090013150226022547b4 (11 bytes) 10:59:11.092 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 71 └─[MultilevelSwitchCCGet] 10:59:11.092 CNTRLR « [Node 056] parameter #31 has value: 100597760 10:59:11.093 CNTRLR » [Node 056] querying parameter #32 value... 10:59:11.100 SERIAL « [ACK] (0x06) 10:59:11.102 SERIAL « 0x0104011301e8 (6 bytes) 10:59:11.103 SERIAL » [ACK] (0x06) 10:59:11.105 DRIVER « [RES] [SendData] was sent: true 10:59:11.231 SERIAL « 0x010700134700000ea2 (9 bytes) 10:59:11.231 SERIAL » [ACK] (0x06) 10:59:11.232 DRIVER « [REQ] [SendData] callback id: 71 transmit status: OK 10:59:11.349 SERIAL « 0x01090004001503260300c1 (11 bytes) 10:59:11.350 CNTRLR [Node 021] [~] [Multilevel Switch] currentValue: 0 => 0 [Endpoint 0] 10:59:11.351 SERIAL » [ACK] (0x06) 10:59:11.353 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 0 10:59:11.362 SERIAL » 0x010a001338037005202548e5 (12 bytes) 10:59:11.363 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 72 └─[ConfigurationCCGet] parameter #: 32 10:59:11.364 CNTRLR [Node 021] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 10:59:11.376 SERIAL « [ACK] (0x06) 10:59:11.386 SERIAL « 0x0104011301e8 (6 bytes) 10:59:11.386 SERIAL » [ACK] (0x06) 10:59:11.387 DRIVER « [RES] [SendData] was sent: true 10:59:11.391 CNTRLR [Node 021] MeterCC: doing a partial interview... 10:59:11.391 CNTRLR » [Node 021] querying meter value (type = Electric, scale = kWh)... 10:59:11.478 SERIAL « 0x010700134800000caf (9 bytes) 10:59:11.478 SERIAL » [ACK] (0x06) 10:59:11.479 DRIVER « [REQ] [SendData] callback id: 72 transmit status: OK 10:59:11.497 SERIAL « 0x010e00040038087006200401ff000069 (16 bytes) 10:59:11.502 CNTRLR [Node 056] [~] [Configuration] 32[255]: 0 => 0 10:59:11.503 CNTRLR [Node 056] [~] [Configuration] 32[65280]: 0 => 0 10:59:11.505 CNTRLR [Node 056] [~] [Configuration] 32[16711680]: 255 => 255 10:59:11.507 CNTRLR [Node 056] [~] [Configuration] 32[4278190080]: 1 => 1 10:59:11.508 SERIAL » [ACK] (0x06) 10:59:11.509 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 4 value: 33488896 10:59:11.514 SERIAL » 0x010a001315033201002549af (12 bytes) 10:59:11.515 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 73 └─[MeterCCGet] duration: kWh 10:59:11.516 CNTRLR « [Node 056] parameter #32 has value: 33488896 10:59:11.516 CNTRLR » [Node 056] querying parameter #33 value... 10:59:11.525 SERIAL « [ACK] (0x06) 10:59:11.526 SERIAL « 0x0104011301e8 (6 bytes) 10:59:11.527 SERIAL » [ACK] (0x06) 10:59:11.528 DRIVER « [RES] [SendData] was sent: true 10:59:11.661 SERIAL « 0x010700134900000eac (9 bytes) 10:59:11.661 SERIAL » [ACK] (0x06) 10:59:11.662 DRIVER « [REQ] [SendData] callback id: 73 transmit status: OK 10:59:11.798 SERIAL « 0x0114000400150e3202212480000000000180000000c0 (22 bytes) 10:59:11.801 CNTRLR [Node 021] [~] [Meter] value[65537]: -214748364.8 => -214748364.8 [Endpoint 0] 10:59:11.802 CNTRLR [Node 021] [~] [Meter] previousValue[65537]: -214748364.8 => -214 [Endpoint 0] 748364.8 10:59:11.803 CNTRLR [Node 021] [~] [Meter] deltaTime[65537]: 1 => 1 [Endpoint 0] 10:59:11.803 SERIAL » [ACK] (0x06) 10:59:11.807 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: -214748364.8 time delta: 1 seconds prev. value: -214748364.8 10:59:11.811 SERIAL » 0x010a00133803700521254ae6 (12 bytes) 10:59:11.812 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 74 └─[ConfigurationCCGet] parameter #: 33 10:59:11.812 CNTRLR » [Node 021] querying meter value (type = Electric, scale = W)... 10:59:11.819 SERIAL « [ACK] (0x06) 10:59:11.823 SERIAL « 0x0104011301e8 (6 bytes) 10:59:11.824 SERIAL » [ACK] (0x06) 10:59:11.825 DRIVER « [RES] [SendData] was sent: true 10:59:11.927 SERIAL « 0x010700134a00000cad (9 bytes) 10:59:11.928 SERIAL » [ACK] (0x06) 10:59:11.928 DRIVER « [REQ] [SendData] callback id: 74 transmit status: OK 10:59:11.947 SERIAL « 0x010e00040038087006210402ff00006b (16 bytes) 10:59:11.949 CNTRLR [Node 056] [~] [Configuration] 33[255]: 0 => 0 10:59:11.951 CNTRLR [Node 056] [~] [Configuration] 33[65280]: 0 => 0 10:59:11.952 CNTRLR [Node 056] [~] [Configuration] 33[16711680]: 255 => 255 10:59:11.953 CNTRLR [Node 056] [~] [Configuration] 33[4278190080]: 2 => 2 10:59:11.954 SERIAL » [ACK] (0x06) 10:59:11.956 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 4 value: 50266112 10:59:11.962 SERIAL » 0x010a00131503320110254bbd (12 bytes) 10:59:11.963 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 75 └─[MeterCCGet] duration: W 10:59:11.963 CNTRLR « [Node 056] parameter #33 has value: 50266112 10:59:11.964 CNTRLR » [Node 056] querying parameter #34 value... 10:59:11.970 SERIAL « [ACK] (0x06) 10:59:11.979 SERIAL « 0x0104011301e8 (6 bytes) 10:59:11.980 SERIAL » [ACK] (0x06) 10:59:11.985 DRIVER « [RES] [SendData] was sent: true 10:59:12.105 SERIAL « 0x010700134b00000eae (9 bytes) 10:59:12.106 SERIAL » [ACK] (0x06) 10:59:12.107 DRIVER « [REQ] [SendData] callback id: 75 transmit status: OK 10:59:12.231 SERIAL « 0x0110000400150a32022134000000000000d1 (18 bytes) 10:59:12.232 CNTRLR [Node 021] [~] [Meter] value[66049]: 0.1 => 0 [Endpoint 0] 10:59:12.233 CNTRLR [Node 021] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 10:59:12.233 SERIAL » [ACK] (0x06) 10:59:12.237 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 10:59:12.241 SERIAL » 0x010a00133803700522254ce3 (12 bytes) 10:59:12.241 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 76 └─[ConfigurationCCGet] parameter #: 34 10:59:12.242 CNTRLR [Node 021] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 10:59:12.253 SERIAL « [ACK] (0x06) 10:59:12.255 SERIAL « 0x0104011301e8 (6 bytes) 10:59:12.256 SERIAL » [ACK] (0x06) 10:59:12.257 DRIVER « [RES] [SendData] was sent: true 10:59:12.259 CNTRLR [Node 021] ConfigurationCC: Loading configuration parameters from device confi g 10:59:12.262 CNTRLR [Node 021] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 10:59:12.265 CNTRLR [Node 021] [Configuration] 1: metadata updated 10:59:12.267 CNTRLR [Node 021] [Configuration] 5: metadata updated 10:59:12.268 CNTRLR [Node 021] [Configuration] 10: metadata updated 10:59:12.270 CNTRLR [Node 021] [Configuration] 11: metadata updated 10:59:12.271 CNTRLR [Node 021] [Configuration] 12: metadata updated 10:59:12.272 CNTRLR [Node 021] [Configuration] 21: metadata updated 10:59:12.274 CNTRLR [Node 021] [Configuration] 30: metadata updated 10:59:12.275 CNTRLR [Node 021] [Configuration] 40: metadata updated 10:59:12.276 CNTRLR [Node 021] [Configuration] 42: metadata updated 10:59:12.278 CNTRLR [Node 021] [Configuration] 60: metadata updated 10:59:12.279 CNTRLR [Node 021] [Configuration] 61: metadata updated 10:59:12.280 CNTRLR [Node 021] [Configuration] 65: metadata updated 10:59:12.282 CNTRLR [Node 021] [Configuration] 66: metadata updated 10:59:12.283 CNTRLR [Node 021] [Configuration] 67: metadata updated 10:59:12.284 CNTRLR [Node 021] [Configuration] 68: metadata updated 10:59:12.285 CNTRLR [Node 021] [Configuration] 110: metadata updated 10:59:12.286 CNTRLR [Node 021] [Configuration] 120: metadata updated 10:59:12.288 CNTRLR [Node 021] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 10:59:12.288 CNTRLR » [Node 021] querying parameter #1 value... 10:59:12.357 SERIAL « 0x010700134c00000cab (9 bytes) 10:59:12.358 SERIAL » [ACK] (0x06) 10:59:12.359 DRIVER « [REQ] [SendData] callback id: 76 transmit status: OK 10:59:12.377 SERIAL « 0x010e00040038087006220404ff00006e (16 bytes) 10:59:12.380 CNTRLR [Node 056] [~] [Configuration] 34[255]: 0 => 0 10:59:12.382 CNTRLR [Node 056] [~] [Configuration] 34[65280]: 0 => 0 10:59:12.383 CNTRLR [Node 056] [~] [Configuration] 34[16711680]: 255 => 255 10:59:12.385 CNTRLR [Node 056] [~] [Configuration] 34[4278190080]: 4 => 4 10:59:12.387 SERIAL » [ACK] (0x06) 10:59:12.388 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 34 value size: 4 value: 83820544 10:59:12.397 SERIAL » 0x010a00131503700501254dec (12 bytes) 10:59:12.398 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 77 └─[ConfigurationCCGet] parameter #: 1 10:59:12.400 CNTRLR « [Node 056] parameter #34 has value: 83820544 10:59:12.401 CNTRLR [Node 056] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 10:59:12.403 CNTRLR [Node 056] ProtectionCC: doing a partial interview... 10:59:12.403 CNTRLR » [Node 056] querying protection status... 10:59:12.473 SERIAL « [ACK] (0x06) 10:59:12.475 SERIAL « 0x0104011301e8 (6 bytes) 10:59:12.475 SERIAL » [ACK] (0x06) 10:59:12.476 DRIVER « [RES] [SendData] was sent: true 10:59:12.558 SERIAL « 0x010700134d00000ea8 (9 bytes) 10:59:12.558 SERIAL » [ACK] (0x06) 10:59:12.559 DRIVER « [REQ] [SendData] callback id: 77 transmit status: OK 10:59:12.671 SERIAL « 0x010b0004001505700601010096 (13 bytes) 10:59:12.674 CNTRLR [Node 021] [~] [Configuration] 1: 0 => 0 10:59:12.676 SERIAL » [ACK] (0x06) 10:59:12.679 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 0 10:59:12.685 SERIAL » 0x0109001338027502254ec3 (11 bytes) 10:59:12.686 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 78 └─[ProtectionCCGet] 10:59:12.686 CNTRLR « [Node 021] parameter #1 has value: 0 10:59:12.687 CNTRLR » [Node 021] querying parameter #5 value... 10:59:12.693 SERIAL « [ACK] (0x06) 10:59:12.696 SERIAL « 0x0104011301e8 (6 bytes) 10:59:12.697 SERIAL » [ACK] (0x06) 10:59:12.698 DRIVER « [RES] [SendData] was sent: true 10:59:12.787 SERIAL « 0x010700134e000009ac (9 bytes) 10:59:12.788 SERIAL » [ACK] (0x06) 10:59:12.788 DRIVER « [REQ] [SendData] callback id: 78 transmit status: OK 10:59:12.805 SERIAL « 0x010a000400380475030000bb (12 bytes) 10:59:12.806 CNTRLR [Node 056] [~] [Protection] local: 0 => 0 [Endpoint 0] 10:59:12.808 CNTRLR [Node 056] [~] [Protection] rf: 0 => 0 [Endpoint 0] 10:59:12.809 SERIAL » [ACK] (0x06) 10:59:12.810 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 10:59:12.814 SERIAL » 0x010a00131503700505254fea (12 bytes) 10:59:12.815 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 79 └─[ConfigurationCCGet] parameter #: 5 10:59:12.815 CNTRLR « [Node 056] received protection status: local: Unprotected rf Unprotected 10:59:12.816 CNTRLR [Node 056] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 10:59:12.833 SERIAL « [ACK] (0x06) 10:59:12.842 SERIAL « 0x0104011301e8 (6 bytes) 10:59:12.843 SERIAL » [ACK] (0x06) 10:59:12.846 DRIVER « [RES] [SendData] was sent: true 10:59:12.848 CNTRLR [Node 056] AssociationCC: doing a partial interview... 10:59:12.849 CNTRLR [Node 056] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 10:59:12.849 CNTRLR [Node 056] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 10:59:12.849 CNTRLR [Node 056] MultiChannelAssociationCC: doing a partial interview... 10:59:12.850 CNTRLR » [Node 056] querying multi channel association group #1... 10:59:12.958 SERIAL « 0x010700134f00000eaa (9 bytes) 10:59:12.958 SERIAL » [ACK] (0x06) 10:59:12.959 DRIVER « [REQ] [SendData] callback id: 79 transmit status: OK 10:59:13.082 SERIAL « 0x010b0004001505700605010092 (13 bytes) 10:59:13.085 CNTRLR [Node 021] [~] [Configuration] 5: 0 => 0 10:59:13.086 SERIAL » [ACK] (0x06) 10:59:13.087 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 1 value: 0 10:59:13.092 SERIAL » 0x01080013180100255088 (10 bytes) 10:59:13.092 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 80 └─[NoOperationCC] 10:59:13.093 CNTRLR « [Node 021] parameter #5 has value: 0 10:59:13.093 CNTRLR » [Node 021] querying parameter #10 value... 10:59:13.100 SERIAL « [ACK] (0x06) 10:59:13.102 SERIAL « 0x0104011301e8 (6 bytes) 10:59:13.102 SERIAL » [ACK] (0x06) 10:59:13.105 DRIVER « [RES] [SendData] was sent: true 10:59:20.337 SERIAL « 0x01070013500102d46c (9 bytes) 10:59:20.338 SERIAL » [ACK] (0x06) 10:59:20.339 DRIVER « [REQ] [SendData] callback id: 80 transmit status: NoAck 10:59:20.357 SERIAL » 0x010a0013150370050a2551fb (12 bytes) 10:59:20.358 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 81 └─[ConfigurationCCGet] parameter #: 10 10:59:20.358 CNTRLR [Node 024] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 10:59:20.359 CNTRLR [Node 024] The node is asleep. 10:59:20.362 CNTRLR [Node 024] ping failed: Failed to send the command after 1 attempts (Status No Ack) 10:59:20.363 CNTRLR » [Node 024] querying node info... 10:59:20.370 SERIAL « [ACK] (0x06) 10:59:20.373 SERIAL « 0x0104011301e8 (6 bytes) 10:59:20.380 SERIAL » [ACK] (0x06) 10:59:20.381 DRIVER « [RES] [SendData] was sent: true 10:59:20.505 SERIAL « 0x010700135100000eb4 (9 bytes) 10:59:20.505 SERIAL » [ACK] (0x06) 10:59:20.506 DRIVER « [REQ] [SendData] callback id: 81 transmit status: OK 10:59:20.624 SERIAL « 0x010c000400150670060a0200ff65 (14 bytes) 10:59:20.630 CNTRLR [Node 021] [~] [Configuration] 10: 255 => 255 10:59:20.632 SERIAL » [ACK] (0x06) 10:59:20.633 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 2 value: 255 10:59:20.642 SERIAL » 0x010800131e010025528c (10 bytes) 10:59:20.648 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 82 └─[NoOperationCC] 10:59:20.649 CNTRLR « [Node 021] parameter #10 has value: 255 10:59:20.649 CNTRLR » [Node 021] querying parameter #11 value... 10:59:20.657 SERIAL « [ACK] (0x06) 10:59:20.662 SERIAL « 0x0104011301e8 (6 bytes) 10:59:20.662 SERIAL » [ACK] (0x06) 10:59:20.664 DRIVER « [RES] [SendData] was sent: true 10:59:27.653 SERIAL « 0x01070013520102bc06 (9 bytes) 10:59:27.653 SERIAL » [ACK] (0x06) 10:59:27.654 DRIVER « [REQ] [SendData] callback id: 82 transmit status: NoAck 10:59:27.670 SERIAL » 0x010a0013150370050b2553f8 (12 bytes) 10:59:27.671 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 83 └─[ConfigurationCCGet] parameter #: 11 10:59:27.671 CNTRLR [Node 030] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 10:59:27.672 CNTRLR [Node 030] The node is asleep. 10:59:27.674 CNTRLR [Node 030] ping failed: Failed to send the command after 1 attempts (Status No Ack) 10:59:27.674 CNTRLR » [Node 030] querying node info... 10:59:27.678 SERIAL « [ACK] (0x06) 10:59:27.682 SERIAL « 0x0104011301e8 (6 bytes) 10:59:27.683 SERIAL » [ACK] (0x06) 10:59:27.684 DRIVER « [RES] [SendData] was sent: true 10:59:27.816 SERIAL « 0x010700135300000eb6 (9 bytes) 10:59:27.816 SERIAL » [ACK] (0x06) 10:59:27.817 DRIVER « [REQ] [SendData] callback id: 83 transmit status: OK 10:59:27.935 SERIAL « 0x010c000400150670060b0200009b (14 bytes) 10:59:27.938 CNTRLR [Node 021] [~] [Configuration] 11: 0 => 0 10:59:27.939 SERIAL » [ACK] (0x06) 10:59:27.940 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 11 value size: 2 value: 0 10:59:27.943 SERIAL » 0x010800131f010025548b (10 bytes) 10:59:27.944 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 84 └─[NoOperationCC] 10:59:27.944 CNTRLR « [Node 021] parameter #11 has value: 0 10:59:27.945 CNTRLR » [Node 021] querying parameter #12 value... 10:59:27.949 SERIAL « [ACK] (0x06) 10:59:27.952 SERIAL « 0x0104011301e8 (6 bytes) 10:59:27.952 SERIAL » [ACK] (0x06) 10:59:27.954 DRIVER « [RES] [SendData] was sent: true 10:59:36.320 SERIAL « 0x010900040014033003ff29 (11 bytes) 10:59:36.321 CNTRLR [Node 020] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:59:36.322 CNTRLR [Node 020] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:59:36.323 SERIAL » [ACK] (0x06) 10:59:36.324 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:59:36.533 SERIAL « 0x010900040014033003ff29 (11 bytes) 10:59:36.534 CNTRLR [Node 020] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:59:36.535 CNTRLR [Node 020] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:59:36.535 SERIAL » [ACK] (0x06) 10:59:36.536 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:59:36.621 SERIAL « 0x010900040014032001ff3b (11 bytes) 10:59:36.622 SERIAL » [ACK] (0x06) 10:59:36.623 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:59:36.624 CNTRLR [Node 020] treating BasicCC Set as a report 10:59:36.624 CNTRLR [Node 020] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:59:37.971 SERIAL « 0x01070013540103eb56 (9 bytes) 10:59:37.971 SERIAL » [ACK] (0x06) 10:59:37.972 DRIVER « [REQ] [SendData] callback id: 84 transmit status: NoAck 10:59:37.977 SERIAL » 0x010a0013150370050c2555f9 (12 bytes) 10:59:37.978 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 85 └─[ConfigurationCCGet] parameter #: 12 10:59:37.978 CNTRLR [Node 031] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 10:59:37.979 CNTRLR [Node 031] The node is asleep. 10:59:37.980 CNTRLR [Node 031] The node is ready to be used 10:59:37.981 CNTRLR [Node 031] ping failed: Failed to send the command after 1 attempts (Status No Ack) 10:59:37.983 CNTRLR [Node 031] ManufacturerSpecificCC: doing a partial interview... 10:59:37.984 CNTRLR [Node 031] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 10:59:37.998 SERIAL « [ACK] (0x06) 10:59:38.000 SERIAL « 0x0104011301e8 (6 bytes) 10:59:38.001 SERIAL » [ACK] (0x06) 10:59:38.002 DRIVER « [RES] [SendData] was sent: true 10:59:38.005 CNTRLR [Node 031] VersionCC: doing a partial interview... 10:59:38.006 CNTRLR [Node 031] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 10:59:38.006 CNTRLR [Node 031] trying to load device config 10:59:38.018 CNTRLR [Node 031] device config loaded 10:59:38.019 CNTRLR [Node 031] BatteryCC: doing a partial interview... 10:59:38.019 CNTRLR » [Node 031] querying battery status... 10:59:38.137 SERIAL « 0x010700135500000eb0 (9 bytes) 10:59:38.138 SERIAL » [ACK] (0x06) 10:59:38.139 DRIVER « [REQ] [SendData] callback id: 85 transmit status: OK 10:59:38.244 SERIAL « 0x010c000400150670060c0200009c (14 bytes) 10:59:38.247 CNTRLR [Node 021] [~] [Configuration] 12: 0 => 0 10:59:38.248 SERIAL » [ACK] (0x06) 10:59:38.251 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 0 10:59:38.257 SERIAL » 0x010800132101002556b7 (10 bytes) 10:59:38.257 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 86 └─[NoOperationCC] 10:59:38.258 CNTRLR « [Node 021] parameter #12 has value: 0 10:59:38.258 CNTRLR » [Node 021] querying parameter #21 value... 10:59:38.263 SERIAL « [ACK] (0x06) 10:59:38.269 SERIAL « 0x0104011301e8 (6 bytes) 10:59:38.269 SERIAL » [ACK] (0x06) 10:59:38.271 DRIVER « [RES] [SendData] was sent: true 10:59:43.846 SERIAL « 0x010f00040036097105000000ff0708004f (17 bytes) 10:59:43.846 SERIAL » [ACK] (0x06) 10:59:43.847 DRIVER « [Node 054] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 10:59:43.856 CNTRLR [Node 054] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 10:59:45.621 SERIAL « 0x01070013560102e05e (9 bytes) 10:59:45.622 SERIAL » [ACK] (0x06) 10:59:45.624 DRIVER « [REQ] [SendData] callback id: 86 transmit status: NoAck 10:59:45.637 SERIAL » 0x010a001315037005152557e2 (12 bytes) 10:59:45.638 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 87 └─[ConfigurationCCGet] parameter #: 21 10:59:45.638 CNTRLR [Node 033] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 10:59:45.650 CNTRLR [Node 033] The node is asleep. 10:59:45.652 CNTRLR [Node 033] The node is ready to be used 10:59:45.656 CNTRLR [Node 033] ping failed: Failed to send the command after 1 attempts (Status No Ack) 10:59:45.661 CNTRLR [Node 033] ManufacturerSpecificCC: doing a partial interview... 10:59:45.662 CNTRLR [Node 033] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 10:59:45.695 SERIAL « [ACK] (0x06) 10:59:45.696 SERIAL « 0x0104011301e8 (6 bytes) 10:59:45.696 SERIAL » [ACK] (0x06) 10:59:45.698 DRIVER « [RES] [SendData] was sent: true 10:59:45.703 CNTRLR [Node 033] VersionCC: doing a partial interview... 10:59:45.704 CNTRLR [Node 033] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 10:59:45.704 CNTRLR [Node 033] trying to load device config 10:59:45.706 CNTRLR [Node 033] no device config loaded 10:59:45.707 CNTRLR [Node 033] ZWavePlusCC: doing a partial interview... 10:59:45.707 CNTRLR [Node 033] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 10:59:45.708 CNTRLR [Node 033] BatteryCC: doing a partial interview... 10:59:45.708 CNTRLR » [Node 033] querying battery status... 10:59:45.859 SERIAL « 0x010700135700000eb2 (9 bytes) 10:59:45.859 SERIAL » [ACK] (0x06) 10:59:45.871 DRIVER « [REQ] [SendData] callback id: 87 transmit status: OK 10:59:45.922 SERIAL « 0x010b0004001505700615010082 (13 bytes) 10:59:45.925 CNTRLR [Node 021] [~] [Configuration] 21: 0 => 0 10:59:45.926 SERIAL » [ACK] (0x06) 10:59:45.927 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 21 value size: 1 value: 0 10:59:45.931 SERIAL » 0x010800132201002558ba (10 bytes) 10:59:45.931 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 88 └─[NoOperationCC] 10:59:45.931 CNTRLR « [Node 021] parameter #21 has value: 0 10:59:45.932 CNTRLR » [Node 021] querying parameter #30 value... 10:59:45.937 SERIAL « [ACK] (0x06) 10:59:45.941 SERIAL « 0x0104011301e8 (6 bytes) 10:59:45.941 SERIAL » [ACK] (0x06) 10:59:45.942 DRIVER « [RES] [SendData] was sent: true 10:59:54.279 SERIAL « 0x0107001358010343f2 (9 bytes) 10:59:54.280 SERIAL » [ACK] (0x06) 10:59:54.281 DRIVER « [REQ] [SendData] callback id: 88 transmit status: NoAck 10:59:54.288 SERIAL » 0x010a0013150370051e2559e7 (12 bytes) 10:59:54.288 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 89 └─[ConfigurationCCGet] parameter #: 30 10:59:54.289 CNTRLR [Node 034] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 10:59:54.289 CNTRLR [Node 034] The node is asleep. 10:59:54.294 CNTRLR [Node 034] The node is ready to be used 10:59:54.296 CNTRLR [Node 034] ping failed: Failed to send the command after 1 attempts (Status No Ack) 10:59:54.298 CNTRLR [Node 034] ManufacturerSpecificCC: doing a partial interview... 10:59:54.299 CNTRLR [Node 034] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 10:59:54.324 SERIAL « [ACK] (0x06) 10:59:54.325 SERIAL « 0x0104011301e8 (6 bytes) 10:59:54.325 SERIAL » [ACK] (0x06) 10:59:54.329 DRIVER « [RES] [SendData] was sent: true 10:59:54.333 CNTRLR [Node 034] VersionCC: doing a partial interview... 10:59:54.333 CNTRLR [Node 034] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 10:59:54.334 CNTRLR [Node 034] trying to load device config 10:59:54.338 CNTRLR [Node 034] no device config loaded 10:59:54.339 CNTRLR [Node 034] ZWavePlusCC: doing a partial interview... 10:59:54.340 CNTRLR [Node 034] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 10:59:54.340 CNTRLR [Node 034] BatteryCC: doing a partial interview... 10:59:54.340 CNTRLR » [Node 034] querying battery status... 10:59:54.440 SERIAL « 0x010700135900000ebc (9 bytes) 10:59:54.440 SERIAL » [ACK] (0x06) 10:59:54.442 DRIVER « [REQ] [SendData] callback id: 89 transmit status: OK 10:59:54.563 SERIAL « 0x010b000400150570061e010089 (13 bytes) 10:59:54.565 CNTRLR [Node 021] [~] [Configuration] 30: 0 => 0 10:59:54.566 SERIAL » [ACK] (0x06) 10:59:54.568 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 0 10:59:54.572 SERIAL » 0x01080013230100255ab9 (10 bytes) 10:59:54.573 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 90 └─[NoOperationCC] 10:59:54.573 CNTRLR « [Node 021] parameter #30 has value: 0 10:59:54.573 CNTRLR » [Node 021] querying parameter #40 value... 10:59:54.578 SERIAL « [ACK] (0x06) 10:59:54.858 SERIAL « 0x0104011301e8 (6 bytes) 10:59:54.859 SERIAL » [ACK] (0x06) 10:59:54.859 DRIVER « [RES] [SendData] was sent: true 11:00:02.210 SERIAL « 0x010700135a0102fc4e (9 bytes) 11:00:02.210 SERIAL » [ACK] (0x06) 11:00:02.212 DRIVER « [REQ] [SendData] callback id: 90 transmit status: NoAck 11:00:02.224 SERIAL » 0x010a00131503700528255bd3 (12 bytes) 11:00:02.225 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 91 └─[ConfigurationCCGet] parameter #: 40 11:00:02.225 CNTRLR [Node 035] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 11:00:02.226 CNTRLR [Node 035] The node is asleep. 11:00:02.229 CNTRLR [Node 035] The node is ready to be used 11:00:02.232 CNTRLR [Node 035] ping failed: Failed to send the command after 1 attempts (Status No Ack) 11:00:02.235 CNTRLR [Node 035] ManufacturerSpecificCC: doing a partial interview... 11:00:02.236 CNTRLR [Node 035] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 11:00:02.273 SERIAL « [ACK] (0x06) 11:00:02.275 SERIAL « 0x0104011301e8 (6 bytes) 11:00:02.275 SERIAL » [ACK] (0x06) 11:00:02.280 DRIVER « [RES] [SendData] was sent: true 11:00:02.284 CNTRLR [Node 035] VersionCC: doing a partial interview... 11:00:02.285 CNTRLR [Node 035] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 11:00:02.286 CNTRLR [Node 035] trying to load device config 11:00:02.288 CNTRLR [Node 035] no device config loaded 11:00:02.288 CNTRLR [Node 035] ZWavePlusCC: doing a partial interview... 11:00:02.289 CNTRLR [Node 035] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 11:00:02.290 CNTRLR [Node 035] BatteryCC: doing a partial interview... 11:00:02.290 CNTRLR » [Node 035] querying battery status... 11:00:02.434 SERIAL « 0x010700135b00000ebe (9 bytes) 11:00:02.434 SERIAL » [ACK] (0x06) 11:00:02.435 DRIVER « [REQ] [SendData] callback id: 91 transmit status: OK 11:00:02.493 SERIAL « 0x010b00040015057006280105ba (13 bytes) 11:00:02.496 CNTRLR [Node 021] [~] [Configuration] 40: 5 => 5 11:00:02.497 SERIAL » [ACK] (0x06) 11:00:02.499 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 5 11:00:02.503 SERIAL » 0x01080013240100255cb8 (10 bytes) 11:00:02.503 DRIVER » [Node 036] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 92 └─[NoOperationCC] 11:00:02.504 CNTRLR « [Node 021] parameter #40 has value: 5 11:00:02.504 CNTRLR » [Node 021] querying parameter #42 value... 11:00:02.509 SERIAL « [ACK] (0x06) 11:00:02.514 SERIAL « 0x0104011301e8 (6 bytes) 11:00:02.514 SERIAL » [ACK] (0x06) 11:00:02.516 DRIVER « [RES] [SendData] was sent: true 11:00:07.131 SERIAL « 0x01090004001403300300d6 (11 bytes) 11:00:07.132 CNTRLR [Node 020] [Binary Sensor] Any: metadata updated [Endpoint 0] 11:00:07.133 CNTRLR [Node 020] [~] [Binary Sensor] Any: true => false [Endpoint 0] 11:00:07.133 SERIAL » [ACK] (0x06) 11:00:07.135 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 11:00:07.259 SERIAL « 0x01090004001403200100c4 (11 bytes) 11:00:07.260 SERIAL » [ACK] (0x06) 11:00:07.261 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 11:00:07.262 CNTRLR [Node 020] treating BasicCC Set as a report 11:00:07.263 CNTRLR [Node 020] [~] [Binary Sensor] Any: false => false [Endpoint 0] 11:00:10.137 SERIAL « 0x010700135c0102fb4f (9 bytes) 11:00:10.138 SERIAL » [ACK] (0x06) 11:00:10.139 DRIVER « [REQ] [SendData] callback id: 92 transmit status: NoAck 11:00:10.150 SERIAL » 0x010a0013150370052a255dd7 (12 bytes) 11:00:10.151 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 93 └─[ConfigurationCCGet] parameter #: 42 11:00:10.152 CNTRLR [Node 036] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 11:00:10.153 CNTRLR [Node 036] The node is asleep. 11:00:10.155 CNTRLR [Node 036] The node is ready to be used 11:00:10.157 CNTRLR [Node 036] ping failed: Failed to send the command after 1 attempts (Status No Ack) 11:00:10.160 CNTRLR [Node 036] ManufacturerSpecificCC: doing a partial interview... 11:00:10.161 CNTRLR [Node 036] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 11:00:10.183 SERIAL « [ACK] (0x06) 11:00:10.185 SERIAL « 0x0104011301e8 (6 bytes) 11:00:10.185 SERIAL » [ACK] (0x06) 11:00:10.190 DRIVER « [RES] [SendData] was sent: true 11:00:10.198 CNTRLR [Node 036] VersionCC: doing a partial interview... 11:00:10.199 CNTRLR [Node 036] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 11:00:10.199 CNTRLR [Node 036] trying to load device config 11:00:10.203 CNTRLR [Node 036] no device config loaded 11:00:10.204 CNTRLR [Node 036] ZWavePlusCC: doing a partial interview... 11:00:10.204 CNTRLR [Node 036] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 11:00:10.205 CNTRLR [Node 036] BatteryCC: doing a partial interview... 11:00:10.205 CNTRLR » [Node 036] querying battery status... 11:00:10.320 SERIAL « 0x010700135d00000eb8 (9 bytes) 11:00:10.321 SERIAL » [ACK] (0x06) 11:00:10.322 DRIVER « [REQ] [SendData] callback id: 93 transmit status: OK 11:00:10.424 SERIAL « 0x010c000400150670062a020000ba (14 bytes) 11:00:10.427 CNTRLR [Node 021] [~] [Configuration] 42: 0 => 0 11:00:10.428 SERIAL » [ACK] (0x06) 11:00:10.429 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 0 11:00:10.433 SERIAL » 0x01080013250100255ebb (10 bytes) 11:00:10.433 DRIVER » [Node 037] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 94 └─[NoOperationCC] 11:00:10.434 CNTRLR « [Node 021] parameter #42 has value: 0 11:00:10.434 CNTRLR » [Node 021] querying parameter #60 value... 11:00:10.441 SERIAL « [ACK] (0x06) 11:00:10.444 SERIAL « 0x0104011301e8 (6 bytes) 11:00:10.444 SERIAL » [ACK] (0x06) 11:00:10.445 DRIVER « [RES] [SendData] was sent: true 11:00:14.768 SERIAL « 0x0110000400360a7105000000ff0700010852 (18 bytes) 11:00:14.769 SERIAL » [ACK] (0x06) 11:00:14.771 DRIVER « [Node 054] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  11:00:14.773 CNTRLR [Node 054] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 11:00:19.054 SERIAL « 0x010700135e01035ee9 (9 bytes) 11:00:19.060 SERIAL » [ACK] (0x06) 11:00:19.061 DRIVER « [REQ] [SendData] callback id: 94 transmit status: NoAck 11:00:19.073 SERIAL » 0x010a0013150370053c255fc3 (12 bytes) 11:00:19.079 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 95 └─[ConfigurationCCGet] parameter #: 60 11:00:19.080 CNTRLR [Node 037] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 11:00:19.081 CNTRLR [Node 037] The node is asleep. 11:00:19.083 CNTRLR [Node 037] The node is ready to be used 11:00:19.086 CNTRLR [Node 037] ping failed: Failed to send the command after 1 attempts (Status No Ack) 11:00:19.090 CNTRLR [Node 037] ManufacturerSpecificCC: doing a partial interview... 11:00:19.091 CNTRLR [Node 037] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 11:00:19.113 SERIAL « [ACK] (0x06) 11:00:19.115 SERIAL « 0x0104011301e8 (6 bytes) 11:00:19.116 SERIAL » [ACK] (0x06) 11:00:19.121 DRIVER « [RES] [SendData] was sent: true 11:00:19.131 CNTRLR [Node 037] VersionCC: doing a partial interview... 11:00:19.132 CNTRLR [Node 037] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 11:00:19.132 CNTRLR [Node 037] trying to load device config 11:00:19.140 CNTRLR [Node 037] no device config loaded 11:00:19.141 CNTRLR [Node 037] ZWavePlusCC: doing a partial interview... 11:00:19.142 CNTRLR [Node 037] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 11:00:19.144 CNTRLR [Node 037] BatteryCC: doing a partial interview... 11:00:19.144 CNTRLR » [Node 037] querying battery status... 11:00:19.246 SERIAL « 0x010700135f00000eba (9 bytes) 11:00:19.246 SERIAL » [ACK] (0x06) 11:00:19.247 DRIVER « [REQ] [SendData] callback id: 95 transmit status: OK 11:00:19.352 SERIAL « 0x010b000400150570063c0101aa (13 bytes) 11:00:19.355 CNTRLR [Node 021] [~] [Configuration] 60: 1 => 1 11:00:19.356 SERIAL » [ACK] (0x06) 11:00:19.357 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 1 value: 1 11:00:19.361 SERIAL » 0x01080013260100256086 (10 bytes) 11:00:19.361 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 96 └─[NoOperationCC] 11:00:19.362 CNTRLR « [Node 021] parameter #60 has value: 1 11:00:19.362 CNTRLR » [Node 021] querying parameter #61 value... 11:00:19.367 SERIAL « [ACK] (0x06) 11:00:20.162 SERIAL « 0x0104011301e8 (6 bytes) 11:00:20.163 SERIAL » [ACK] (0x06) 11:00:20.164 DRIVER « [RES] [SendData] was sent: true 11:00:31.047 SERIAL « 0x010f00040036097105000000ff0708004f (17 bytes) 11:00:31.048 SERIAL » [ACK] (0x06) 11:00:31.049 DRIVER « [Node 054] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 11:00:31.053 CNTRLR [Node 054] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 11:00:31.787 SERIAL « 0x01070013600104d957 (9 bytes) 11:00:31.788 SERIAL » [ACK] (0x06) 11:00:31.788 DRIVER « [REQ] [SendData] callback id: 96 transmit status: NoAck 11:00:31.793 SERIAL » 0x010a0013150370053d2561fc (12 bytes) 11:00:31.794 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 97 └─[ConfigurationCCGet] parameter #: 61 11:00:31.794 CNTRLR [Node 038] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 11:00:31.795 CNTRLR [Node 038] The node is asleep. 11:00:31.796 CNTRLR [Node 038] The node is ready to be used 11:00:31.797 CNTRLR [Node 038] ping failed: Failed to send the command after 1 attempts (Status No Ack) 11:00:31.799 CNTRLR [Node 038] ManufacturerSpecificCC: doing a partial interview... 11:00:31.800 CNTRLR [Node 038] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 11:00:31.810 SERIAL « [ACK] (0x06) 11:00:31.816 SERIAL « 0x0104011301e8 (6 bytes) 11:00:31.816 SERIAL » [ACK] (0x06) 11:00:31.818 DRIVER « [RES] [SendData] was sent: true 11:00:31.821 CNTRLR [Node 038] VersionCC: doing a partial interview... 11:00:31.821 CNTRLR [Node 038] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 11:00:31.822 CNTRLR [Node 038] trying to load device config 11:00:31.824 CNTRLR [Node 038] no device config loaded 11:00:31.824 CNTRLR [Node 038] ZWavePlusCC: doing a partial interview... 11:00:31.825 CNTRLR [Node 038] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 11:00:31.825 CNTRLR [Node 038] BatteryCC: doing a partial interview... 11:00:31.825 CNTRLR » [Node 038] querying battery status... 11:00:31.941 SERIAL « 0x010700136100000e84 (9 bytes) 11:00:31.941 SERIAL » [ACK] (0x06) 11:00:31.942 DRIVER « [REQ] [SendData] callback id: 97 transmit status: OK 11:00:32.062 SERIAL « 0x010b000400150570063d0163c9 (13 bytes) 11:00:32.065 CNTRLR [Node 021] [~] [Configuration] 61: 99 => 99 11:00:32.066 SERIAL » [ACK] (0x06) 11:00:32.067 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 61 value size: 1 value: 99 11:00:32.071 SERIAL » 0x01080013270100256285 (10 bytes) 11:00:32.071 DRIVER » [Node 039] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 98 └─[NoOperationCC] 11:00:32.072 CNTRLR « [Node 021] parameter #61 has value: 99 11:00:32.072 CNTRLR » [Node 021] querying parameter #65 value... 11:00:32.076 SERIAL « [ACK] (0x06) 11:00:32.080 SERIAL « 0x0104011301e8 (6 bytes) 11:00:32.081 SERIAL » [ACK] (0x06) 11:00:32.082 DRIVER « [RES] [SendData] was sent: true 11:00:41.170 SERIAL « 0x0113000400240d600d00017105000000ff01020025 (21 bytes) 11:00:41.172 SERIAL » [ACK] (0x06) 11:00:41.174 DRIVER « [Node 036] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCReport] notification type: Smoke Alarm notification status: 255 notification event: Unknown (0x02) 11:00:41.178 CNTRLR [Node 036] [+] [Notification] Smoke Alarm[Sensor status]: 2 [Endpoint 0] 11:00:41.256 SERIAL « 0x0113000400240d600d00017105000000ff01020025 (21 bytes) 11:00:41.257 SERIAL » [ACK] (0x06) 11:00:41.259 DRIVER « [Node 036] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCReport] notification type: Smoke Alarm notification status: 255 notification event: Unknown (0x02) 11:00:41.261 CNTRLR [Node 036] [~] [Notification] Smoke Alarm[Sensor status]: 2 => 2 [Endpoint 0] 11:00:41.341 SERIAL « 0x010f00040024097105000000ff01020051 (17 bytes) 11:00:41.342 SERIAL » [ACK] (0x06) 11:00:41.343 DRIVER « [Node 036] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Smoke Alarm notification status: 255 notification event: Unknown (0x02) 11:00:41.347 CNTRLR [Node 036] [~] [Notification] Smoke Alarm[Sensor status]: 2 => 2 [Endpoint 0] 11:00:41.401 SERIAL « 0x010f00040024097105000000ff01020051 (17 bytes) 11:00:41.413 SERIAL » [ACK] (0x06) 11:00:41.416 DRIVER « [Node 036] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Smoke Alarm notification status: 255 notification event: Unknown (0x02) 11:00:41.420 CNTRLR [Node 036] [~] [Notification] Smoke Alarm[Sensor status]: 2 => 2 [Endpoint 0] 11:00:41.751 SERIAL « 0x010d0004002407600d00018003556f (15 bytes) 11:00:41.753 CNTRLR [Node 036] [~] [Battery] level: 85 => 85 [Endpoint 0] 11:00:41.754 CNTRLR [Node 036] [~] [Battery] isLow: false => false [Endpoint 0] 11:00:41.754 SERIAL » [ACK] (0x06) 11:00:41.759 DRIVER « [Node 036] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BatteryCCReport] level: 85 is low: false 11:00:41.830 SERIAL « 0x0109000400240380035503 (11 bytes) 11:00:41.831 CNTRLR [Node 036] [~] [Battery] level: 85 => 85 [Endpoint 0] 11:00:41.832 CNTRLR [Node 036] [~] [Battery] isLow: false => false [Endpoint 0] 11:00:41.832 SERIAL » [ACK] (0x06) 11:00:41.834 DRIVER « [Node 036] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 85 is low: false 11:00:43.099 SERIAL « 0x0114000400240e600d00017105000000ff0100010220 (22 bytes) 11:00:43.100 SERIAL » [ACK] (0x06) 11:00:43.101 DRIVER « [Node 036] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCReport] notification type: Smoke Alarm notification status: 255 notification event: Unknown (0x00) event parameters:  11:00:43.102 CNTRLR [Node 036] [~] [Notification] Smoke Alarm[Sensor status]: 2 => 0 [Endpoint 0] 11:00:43.183 SERIAL « 0x0110000400240a7105000000ff010001024c (18 bytes) 11:00:43.184 SERIAL » [ACK] (0x06) 11:00:43.185 DRIVER « [Node 036] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Smoke Alarm notification status: 255 notification event: Unknown (0x00) event parameters:  11:00:43.186 CNTRLR [Node 036] [~] [Notification] Smoke Alarm[Sensor status]: 0 => 0 [Endpoint 0] 11:00:44.625 SERIAL « 0x01070013620104e76b (9 bytes) 11:00:44.626 SERIAL » [ACK] (0x06) 11:00:44.626 DRIVER « [REQ] [SendData] callback id: 98 transmit status: NoAck 11:00:44.631 SERIAL » 0x010a00131503700541256382 (12 bytes) 11:00:44.632 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 99 └─[ConfigurationCCGet] parameter #: 65 11:00:44.632 CNTRLR [Node 039] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 11:00:44.633 CNTRLR [Node 039] The node is asleep. 11:00:44.634 CNTRLR [Node 039] The node is ready to be used 11:00:44.635 CNTRLR [Node 039] ping failed: Failed to send the command after 1 attempts (Status No Ack) 11:00:44.637 CNTRLR [Node 039] ManufacturerSpecificCC: doing a partial interview... 11:00:44.637 CNTRLR [Node 039] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 11:00:44.654 SERIAL « [ACK] (0x06) 11:00:44.656 SERIAL « 0x0104011301e8 (6 bytes) 11:00:44.657 SERIAL » [ACK] (0x06) 11:00:44.659 DRIVER « [RES] [SendData] was sent: true 11:00:44.662 CNTRLR [Node 039] VersionCC: doing a partial interview... 11:00:44.663 CNTRLR [Node 039] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 11:00:44.663 CNTRLR [Node 039] trying to load device config 11:00:44.667 CNTRLR [Node 039] no device config loaded 11:00:44.668 CNTRLR [Node 039] ZWavePlusCC: doing a partial interview... 11:00:44.668 CNTRLR [Node 039] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 11:00:44.669 CNTRLR [Node 039] BatteryCC: doing a partial interview... 11:00:44.670 CNTRLR » [Node 039] querying battery status... 11:00:44.828 SERIAL « 0x010700136300000e86 (9 bytes) 11:00:44.828 SERIAL » [ACK] (0x06) 11:00:44.830 DRIVER « [REQ] [SendData] callback id: 99 transmit status: OK 11:00:44.904 SERIAL « 0x010c0004001506700641020064b5 (14 bytes) 11:00:44.910 CNTRLR [Node 021] [~] [Configuration] 65: 100 => 100 11:00:44.912 SERIAL » [ACK] (0x06) 11:00:44.914 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 65 value size: 2 value: 100 11:00:44.925 SERIAL » 0x01080013360100256492 (10 bytes) 11:00:44.926 DRIVER » [Node 054] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 100 └─[NoOperationCC] 11:00:44.927 CNTRLR « [Node 021] parameter #65 has value: 100 11:00:44.927 CNTRLR » [Node 021] querying parameter #66 value... 11:00:44.938 SERIAL « [ACK] (0x06) 11:00:44.940 SERIAL « 0x0104011301e8 (6 bytes) 11:00:44.940 SERIAL » [ACK] (0x06) 11:00:44.942 DRIVER « [RES] [SendData] was sent: true 11:00:45.767 SERIAL « 0x0113000400240d600d00017105000000ff01020025 (21 bytes) 11:00:45.768 SERIAL » [ACK] (0x06) 11:00:45.770 DRIVER « [Node 036] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCReport] notification type: Smoke Alarm notification status: 255 notification event: Unknown (0x02) 11:00:45.773 CNTRLR [Node 036] [~] [Notification] Smoke Alarm[Sensor status]: 0 => 2 [Endpoint 0] 11:00:45.858 SERIAL « 0x0113000400240d600d00017105000000ff01020025 (21 bytes) 11:00:45.859 SERIAL » [ACK] (0x06) 11:00:45.860 DRIVER « [Node 036] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCReport] notification type: Smoke Alarm notification status: 255 notification event: Unknown (0x02) 11:00:45.863 CNTRLR [Node 036] [~] [Notification] Smoke Alarm[Sensor status]: 2 => 2 [Endpoint 0] 11:00:46.101 SERIAL « 0x0113000400240d600d00017105000000ff01020025 (21 bytes) 11:00:46.102 SERIAL » [ACK] (0x06) 11:00:46.102 DRIVER « [Node 036] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCReport] notification type: Smoke Alarm notification status: 255 notification event: Unknown (0x02) 11:00:46.104 CNTRLR [Node 036] [~] [Notification] Smoke Alarm[Sensor status]: 2 => 2 [Endpoint 0] 11:00:46.689 SERIAL « 0x0113000410240d600d00017105000000ff01020035 (21 bytes) 11:00:46.690 SERIAL » [ACK] (0x06) 11:00:46.691 DRIVER « [Node 036] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCReport] notification type: Smoke Alarm notification status: 255 notification event: Unknown (0x02) 11:00:46.694 CNTRLR [Node 036] [~] [Notification] Smoke Alarm[Sensor status]: 2 => 2 [Endpoint 0] 11:00:46.758 SERIAL « 0x010f00040024097105000000ff01020051 (17 bytes) 11:00:46.758 SERIAL » [ACK] (0x06) 11:00:46.759 DRIVER « [Node 036] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Smoke Alarm notification status: 255 notification event: Unknown (0x02) 11:00:46.761 CNTRLR [Node 036] [~] [Notification] Smoke Alarm[Sensor status]: 2 => 2 [Endpoint 0] 11:00:46.865 SERIAL « 0x010f00040024097105000000ff01020051 (17 bytes) 11:00:46.866 SERIAL » [ACK] (0x06) 11:00:46.867 DRIVER « [Node 036] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Smoke Alarm notification status: 255 notification event: Unknown (0x02) 11:00:46.869 CNTRLR [Node 036] [~] [Notification] Smoke Alarm[Sensor status]: 2 => 2 [Endpoint 0] 11:00:47.821 SERIAL « 0x0113000410240d600d00017105000000ff01020035 (21 bytes) 11:00:47.822 SERIAL » [ACK] (0x06) 11:00:47.824 DRIVER « [Node 036] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCReport] notification type: Smoke Alarm notification status: 255 notification event: Unknown (0x02) 11:00:47.827 CNTRLR [Node 036] [~] [Notification] Smoke Alarm[Sensor status]: 2 => 2 [Endpoint 0] 11:00:48.027 SERIAL « 0x0114000400240e600d00017105000000ff0100010220 (22 bytes) 11:00:48.028 SERIAL » [ACK] (0x06) 11:00:48.030 DRIVER « [Node 036] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCReport] notification type: Smoke Alarm notification status: 255 notification event: Unknown (0x00) event parameters:  11:00:48.034 CNTRLR [Node 036] [~] [Notification] Smoke Alarm[Sensor status]: 2 => 0 [Endpoint 0] 11:00:48.179 SERIAL « 0x0110000400240a7105000000ff010001024c (18 bytes) 11:00:48.180 SERIAL » [ACK] (0x06) 11:00:48.181 DRIVER « [Node 036] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Smoke Alarm notification status: 255 notification event: Unknown (0x00) event parameters:  11:00:48.184 CNTRLR [Node 036] [~] [Notification] Smoke Alarm[Sensor status]: 0 => 0 [Endpoint 0] 11:00:53.544 SERIAL « 0x010700136401035dd0 (9 bytes) 11:00:53.544 SERIAL » [ACK] (0x06) 11:00:53.545 DRIVER « [REQ] [SendData] callback id: 100 transmit status: NoAck 11:00:53.556 SERIAL » 0x010a00131503700542256587 (12 bytes) 11:00:53.557 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 101 └─[ConfigurationCCGet] parameter #: 66 11:00:53.558 CNTRLR [Node 054] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 11:00:53.558 CNTRLR [Node 054] The node is asleep. 11:00:53.561 CNTRLR [Node 054] The node is ready to be used 11:00:53.563 CNTRLR [Node 054] ping failed: Failed to send the command after 1 attempts (Status No Ack) 11:00:53.566 CNTRLR [Node 054] ManufacturerSpecificCC: doing a partial interview... 11:00:53.566 CNTRLR [Node 054] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 11:00:53.587 SERIAL « [ACK] (0x06) 11:00:53.589 SERIAL « 0x0104011301e8 (6 bytes) 11:00:53.589 SERIAL » [ACK] (0x06) 11:00:53.594 DRIVER « [RES] [SendData] was sent: true 11:00:53.600 CNTRLR [Node 054] VersionCC: doing a partial interview... 11:00:53.601 CNTRLR [Node 054] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 11:00:53.601 CNTRLR [Node 054] trying to load device config 11:00:53.771 CNTRLR [Node 054] device config loaded 11:00:53.772 SERIAL « 0x010700136500000e80 (9 bytes) 11:00:53.772 SERIAL » [ACK] (0x06) 11:00:53.773 DRIVER « [REQ] [SendData] callback id: 101 transmit status: OK 11:00:53.786 CNTRLR [Node 054] ZWavePlusCC: doing a partial interview... 11:00:53.787 CNTRLR [Node 054] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 11:00:53.787 CNTRLR [Node 054] BatteryCC: doing a partial interview... 11:00:53.787 CNTRLR » [Node 054] querying battery status... 11:00:53.824 SERIAL « 0x010c0004001506700642020003d1 (14 bytes) 11:00:53.827 CNTRLR [Node 021] [~] [Configuration] 66: 3 => 3 11:00:53.828 SERIAL » [ACK] (0x06) 11:00:53.829 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 66 value size: 2 value: 3 11:00:53.833 SERIAL » 0x0109001317028002256631 (11 bytes) 11:00:53.833 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 102 └─[BatteryCCGet] 11:00:53.833 CNTRLR « [Node 021] parameter #66 has value: 3 11:00:53.834 CNTRLR » [Node 021] querying parameter #67 value... 11:00:53.838 SERIAL « [ACK] (0x06) 11:00:53.841 SERIAL « 0x0104011301e8 (6 bytes) 11:00:53.841 SERIAL » [ACK] (0x06) 11:00:53.844 DRIVER « [RES] [SendData] was sent: true 11:01:01.879 SERIAL « 0x0107001366010325aa (9 bytes) 11:01:01.880 SERIAL » [ACK] (0x06) 11:01:01.880 DRIVER « [REQ] [SendData] callback id: 102 transmit status: NoAck 11:01:01.882 CNTRLR [Node 023] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 11:01:02.386 SERIAL » 0x0109001317028002256631 (11 bytes) 11:01:02.386 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 102 └─[BatteryCCGet] 11:01:02.388 SERIAL « [ACK] (0x06) 11:01:02.397 SERIAL « 0x0104011301e8 (6 bytes) 11:01:02.397 SERIAL » [ACK] (0x06) 11:01:02.398 DRIVER « [RES] [SendData] was sent: true 11:01:09.865 SERIAL « 0x01070013660102eb65 (9 bytes) 11:01:09.866 SERIAL » [ACK] (0x06) 11:01:09.866 DRIVER « [REQ] [SendData] callback id: 102 transmit status: NoAck 11:01:09.868 CNTRLR [Node 023] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 11:01:10.374 SERIAL » 0x0109001317028002256631 (11 bytes) 11:01:10.375 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 102 └─[BatteryCCGet] 11:01:10.377 SERIAL « [ACK] (0x06) 11:01:10.386 SERIAL « 0x0104011301e8 (6 bytes) 11:01:10.386 SERIAL » [ACK] (0x06) 11:01:10.387 DRIVER « [RES] [SendData] was sent: true 11:01:17.649 SERIAL « 0x01070013660102d759 (9 bytes) 11:01:17.650 SERIAL » [ACK] (0x06) 11:01:17.652 DRIVER « [REQ] [SendData] callback id: 102 transmit status: NoAck 11:01:17.672 SERIAL » 0x010a00130e038e0201256724 (12 bytes) 11:01:17.673 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 103 └─[MultiChannelAssociationCCGet] group id: 1 11:01:17.675 CNTRLR [Node 023] The node did not respond after 3 attempts. It is probably asleep, moving its messages to the wakeup queue. 11:01:17.677 CNTRLR [Node 023] The node is asleep. 11:01:17.680 CNTRLR [Node 023] Error during node interview: Failed to send the command after 3 att empts (Status NoAck) 11:01:17.683 SERIAL « [ACK] (0x06) 11:01:17.688 SERIAL « 0x0104011301e8 (6 bytes) 11:01:17.688 SERIAL » [ACK] (0x06) 11:01:17.690 DRIVER « [RES] [SendData] was sent: true 11:01:17.705 SERIAL « 0x01070013670000028e (9 bytes) 11:01:17.706 SERIAL » [ACK] (0x06) 11:01:17.706 DRIVER « [REQ] [SendData] callback id: 103 transmit status: OK 11:01:17.717 SERIAL « 0x01100004000e0a8e03010500010306071174 (18 bytes) 11:01:17.719 SERIAL » [ACK] (0x06) 11:01:17.720 CNTRLR [Node 014] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 11:01:17.722 CNTRLR [Node 014] [~] [Multi Channel Association] nodeIds[1]: 1,3,6,7,17 => 1,3,6,7,1 7 11:01:17.723 CNTRLR [Node 014] [~] [Multi Channel Association] endpoints[1]: => 11:01:17.725 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: 1, 3, 6, 7, 17 endpoints: 11:01:17.731 SERIAL » 0x010a001338038e020125681d (12 bytes) 11:01:17.732 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 104 └─[MultiChannelAssociationCCGet] group id: 1 11:01:17.732 CNTRLR « [Node 014] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: 1, 3, 6, 7, 17 currently assigned endpoints: 11:01:17.732 CNTRLR » [Node 014] querying multi channel association group #2... 11:01:17.738 SERIAL « [ACK] (0x06) 11:01:17.741 SERIAL « 0x0104011301e8 (6 bytes) 11:01:17.741 SERIAL » [ACK] (0x06) 11:01:17.742 DRIVER « [RES] [SendData] was sent: true 11:01:17.761 SERIAL « 0x010700136800000380 (9 bytes) 11:01:17.761 SERIAL » [ACK] (0x06) 11:01:17.762 DRIVER « [REQ] [SendData] callback id: 104 transmit status: OK 11:01:17.780 SERIAL « 0x010e00040038088e0301010000010049 (16 bytes) 11:01:17.780 SERIAL » [ACK] (0x06) 11:01:17.781 CNTRLR [Node 056] [~] [Multi Channel Association] maxNodes[1]: 1 => 1 11:01:17.783 CNTRLR [Node 056] [~] [Multi Channel Association] nodeIds[1]: => 11:01:17.784 CNTRLR [Node 056] [~] [Multi Channel Association] endpoints[1]: [object Object] => [o bject Object] 11:01:17.785 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 1 node ids: endpoints: 1:0 11:01:17.790 SERIAL » 0x010a00130e038e0202256929 (12 bytes) 11:01:17.790 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 105 └─[MultiChannelAssociationCCGet] group id: 2 11:01:17.791 CNTRLR « [Node 056] received information for multi channel association group #1: maximum # of nodes: 1 currently assigned nodes: currently assigned endpoints: 1:0 11:01:17.791 CNTRLR » [Node 056] querying multi channel association group #2... 11:01:17.798 SERIAL « [ACK] (0x06) 11:01:17.800 SERIAL « 0x0104011301e8 (6 bytes) 11:01:17.800 SERIAL » [ACK] (0x06) 11:01:17.801 DRIVER « [RES] [SendData] was sent: true 11:01:17.817 SERIAL « 0x010700136900000280 (9 bytes) 11:01:17.818 SERIAL » [ACK] (0x06) 11:01:17.819 DRIVER « [REQ] [SendData] callback id: 105 transmit status: OK 11:01:17.826 SERIAL « 0x010b0004000e058e0302050071 (13 bytes) 11:01:17.827 SERIAL » [ACK] (0x06) 11:01:17.828 CNTRLR [Node 014] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 11:01:17.830 CNTRLR [Node 014] [~] [Multi Channel Association] nodeIds[2]: => 11:01:17.831 CNTRLR [Node 014] [~] [Multi Channel Association] endpoints[2]: => 11:01:17.832 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 11:01:17.836 SERIAL » 0x010a001338038e0202256a1c (12 bytes) 11:01:17.837 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 106 └─[MultiChannelAssociationCCGet] group id: 2 11:01:17.837 CNTRLR « [Node 014] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 11:01:17.837 CNTRLR » [Node 014] querying additional non-multi-channel association groups... 11:01:17.838 CNTRLR » [Node 014] querying association group #3... 11:01:17.889 SERIAL « [ACK] (0x06) 11:01:17.892 SERIAL « 0x0104011301e8 (6 bytes) 11:01:17.892 SERIAL » [ACK] (0x06) 11:01:17.894 DRIVER « [RES] [SendData] was sent: true 11:01:17.902 SERIAL « 0x010700136a00000283 (9 bytes) 11:01:17.903 SERIAL » [ACK] (0x06) 11:01:17.906 DRIVER « [REQ] [SendData] callback id: 106 transmit status: OK 11:01:17.912 SERIAL « 0x010b00040038058e0302050047 (13 bytes) 11:01:17.912 SERIAL » [ACK] (0x06) 11:01:17.914 CNTRLR [Node 056] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 11:01:17.915 CNTRLR [Node 056] [~] [Multi Channel Association] nodeIds[2]: => 11:01:17.916 CNTRLR [Node 056] [~] [Multi Channel Association] endpoints[2]: => 11:01:17.918 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 11:01:17.930 SERIAL » 0x010a00130e03850203256b21 (12 bytes) 11:01:17.931 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 107 └─[AssociationCCGet] group id: 3 11:01:17.932 CNTRLR « [Node 056] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 11:01:17.932 CNTRLR » [Node 056] querying multi channel association group #3... 11:01:17.937 SERIAL « [ACK] (0x06) 11:01:17.940 SERIAL « 0x0104011301e8 (6 bytes) 11:01:17.941 SERIAL » [ACK] (0x06) 11:01:17.945 DRIVER « [RES] [SendData] was sent: true 11:01:17.956 SERIAL « 0x010700136b00000282 (9 bytes) 11:01:17.957 SERIAL » [ACK] (0x06) 11:01:17.958 DRIVER « [REQ] [SendData] callback id: 107 transmit status: OK 11:01:17.968 SERIAL « 0x010c0004000e068503030100017a (14 bytes) 11:01:17.969 SERIAL » [ACK] (0x06) 11:01:17.971 CNTRLR [Node 014] [~] [Association] maxNodes[3]: 1 => 1 [internal] 11:01:17.971 CNTRLR [Node 014] [~] [Association] nodeIds[3]: 1 => 1 [internal] 11:01:17.972 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 11:01:17.976 SERIAL » 0x010a001338038e0203256c1b (12 bytes) 11:01:17.976 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 108 └─[MultiChannelAssociationCCGet] group id: 3 11:01:17.977 CNTRLR « [Node 014] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 11:01:17.978 CNTRLR [Node 014] [~] [Association] hasLifeline: true => true [internal] 11:01:17.979 CNTRLR [Node 014] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 11:01:17.990 SERIAL « [ACK] (0x06) 11:01:17.993 SERIAL « 0x0104011301e8 (6 bytes) 11:01:17.993 SERIAL » [ACK] (0x06) 11:01:17.994 DRIVER « [RES] [SendData] was sent: true 11:01:17.996 CNTRLR [Node 014] Interview stage completed: CommandClasses 11:01:17.997 CNTRLR [Node 014] Interview stage completed: OverwriteConfig 11:01:17.997 CNTRLR » [Node 014] requesting node neighbors... 11:01:18.005 SERIAL « 0x010700136c00000285 (9 bytes) 11:01:18.005 SERIAL » [ACK] (0x06) 11:01:18.006 DRIVER « [REQ] [SendData] callback id: 108 transmit status: OK 11:01:18.023 SERIAL « 0x010b00040038058e0303050046 (13 bytes) 11:01:18.024 SERIAL » [ACK] (0x06) 11:01:18.025 CNTRLR [Node 056] [~] [Multi Channel Association] maxNodes[3]: 5 => 5 11:01:18.026 CNTRLR [Node 056] [~] [Multi Channel Association] nodeIds[3]: => 11:01:18.027 CNTRLR [Node 056] [~] [Multi Channel Association] endpoints[3]: => 11:01:18.031 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 3 maximum # of nodes: 5 node ids: endpoints: 11:01:18.041 SERIAL » 0x010700800e00000076 (9 bytes) 11:01:18.041 DRIVER » [Node 014] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 11:01:18.042 CNTRLR « [Node 056] received information for multi channel association group #3: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 11:01:18.043 CNTRLR [Node 056] [~] [Association] hasLifeline: true => true [internal] 11:01:18.043 CNTRLR [Node 056] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 11:01:18.044 CNTRLR [Node 056] AssociationGroupInfoCC: doing a partial interview... 11:01:18.045 CNTRLR [Node 056] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 11:01:18.047 CNTRLR [Node 056] CentralSceneCC: doing a partial interview... 11:01:18.047 CNTRLR [Node 056] [~] [Central Scene] interviewComplete: true [Endpoint 0] [internal] => true 11:01:18.048 CNTRLR [Node 056] NotificationCC: doing a partial interview... 11:01:18.048 CNTRLR » [Node 056] querying notification status for Power Management... 11:01:18.055 SERIAL « [ACK] (0x06) 11:01:18.056 SERIAL « 0x0120018005c0d7604f00a00000000000000000000000000000000000000000000 (34 bytes) 0c3 11:01:18.057 SERIAL » [ACK] (0x06) 11:01:18.059 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 15, 16, 17, 18, 19, 21, 23, 24, 30, 31, 33, 34, 35, 36, 39, 54, 56 11:01:18.069 SERIAL » 0x010a00131503700543256d8e (12 bytes) 11:01:18.070 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 109 └─[ConfigurationCCGet] parameter #: 67 11:01:18.071 CNTRLR « [Node 014] node neighbors received: 1, 3, 15, 16, 17, 18, 19, 21, 23, 24, 30 , 31, 33, 34, 35, 36, 39, 54, 56 11:01:18.071 CNTRLR [Node 014] Interview stage completed: Neighbors 11:01:18.072 CNTRLR [Node 014] Interview completed 11:01:18.078 SERIAL « [ACK] (0x06) 11:01:18.081 SERIAL « 0x0104011301e8 (6 bytes) 11:01:18.082 SERIAL » [ACK] (0x06) 11:01:18.083 DRIVER « [RES] [SendData] was sent: true 11:01:18.214 SERIAL « 0x010700136d00000e88 (9 bytes) 11:01:18.214 SERIAL » [ACK] (0x06) 11:01:18.216 DRIVER « [REQ] [SendData] callback id: 109 transmit status: OK 11:01:18.333 SERIAL « 0x010b00040015057006430100d4 (13 bytes) 11:01:18.337 CNTRLR [Node 021] [~] [Configuration] 67: 0 => 0 11:01:18.338 SERIAL » [ACK] (0x06) 11:01:18.340 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 67 value size: 1 value: 0 11:01:18.351 SERIAL » 0x010c001338057104000800256eeb (14 bytes) 11:01:18.351 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 110 └─[NotificationCCGet] notification type: Power Management 11:01:18.352 CNTRLR « [Node 021] parameter #67 has value: 0 11:01:18.352 CNTRLR » [Node 021] querying parameter #68 value... 11:01:18.356 SERIAL « [ACK] (0x06) 11:01:18.360 SERIAL « 0x0104011301e8 (6 bytes) 11:01:18.360 SERIAL » [ACK] (0x06) 11:01:18.363 DRIVER « [RES] [SendData] was sent: true 11:01:18.458 SERIAL « 0x010700136e00000b8e (9 bytes) 11:01:18.459 SERIAL » [ACK] (0x06) 11:01:18.459 DRIVER « [REQ] [SendData] callback id: 110 transmit status: OK 11:01:18.478 SERIAL « 0x010f00040038097105000000ff08fe00b8 (17 bytes) 11:01:18.479 SERIAL » [ACK] (0x06) 11:01:18.479 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 11:01:18.483 SERIAL » 0x010a00131503700544256f8b (12 bytes) 11:01:18.483 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 111 └─[ConfigurationCCGet] parameter #: 68 11:01:18.484 CNTRLR [Node 056] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 0] 54 11:01:18.484 CNTRLR » [Node 056] querying notification status for System... 11:01:18.487 SERIAL « [ACK] (0x06) 11:01:18.491 SERIAL « 0x0104011301e8 (6 bytes) 11:01:18.491 SERIAL » [ACK] (0x06) 11:01:18.492 DRIVER « [RES] [SendData] was sent: true 11:01:18.626 SERIAL « 0x010700136f00000e8a (9 bytes) 11:01:18.626 SERIAL » [ACK] (0x06) 11:01:18.627 DRIVER « [REQ] [SendData] callback id: 111 transmit status: OK 11:01:18.742 SERIAL « 0x010b00040015057006440100d3 (13 bytes) 11:01:18.744 CNTRLR [Node 021] [~] [Configuration] 68: 0 => 0 11:01:18.745 SERIAL » [ACK] (0x06) 11:01:18.746 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 68 value size: 1 value: 0 11:01:18.754 SERIAL » 0x010c0013380571040009002570f4 (14 bytes) 11:01:18.754 DRIVER » [Node 056] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 112 └─[NotificationCCGet] notification type: System 11:01:18.754 CNTRLR « [Node 021] parameter #68 has value: 0 11:01:18.755 CNTRLR » [Node 021] querying parameter #110 value... 11:01:18.759 SERIAL « [ACK] (0x06) 11:01:18.764 SERIAL « 0x0104011301e8 (6 bytes) 11:01:18.765 SERIAL » [ACK] (0x06) 11:01:18.765 DRIVER « [RES] [SendData] was sent: true 11:01:18.879 SERIAL « 0x0110000400360a7105000000ff0700010852 (18 bytes) 11:01:18.880 SERIAL » [ACK] (0x06) 11:01:18.881 DRIVER « [Node 054] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  11:01:18.882 CNTRLR [Node 054] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 11:01:18.927 SERIAL « 0x01070013700000108b (9 bytes) 11:01:18.927 SERIAL » [ACK] (0x06) 11:01:18.928 DRIVER « [REQ] [SendData] callback id: 112 transmit status: OK 11:01:18.946 SERIAL « 0x010f00040038097105000000ff09fe00b9 (17 bytes) 11:01:18.947 SERIAL » [ACK] (0x06) 11:01:18.948 DRIVER « [Node 056] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: System notification status: 255 notification event: Unknown (0xfe) 11:01:18.955 SERIAL » 0x010a0013150370056e2571bf (12 bytes) 11:01:18.955 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 113 └─[ConfigurationCCGet] parameter #: 110 11:01:18.956 CNTRLR [Node 056] [~] [Notification] System[unknown]: 254 => 254 [Endpoint 0] 11:01:18.956 CNTRLR [Node 056] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 11:01:18.964 SERIAL « [ACK] (0x06) 11:01:18.966 SERIAL « 0x0104011301e8 (6 bytes) 11:01:18.967 SERIAL » [ACK] (0x06) 11:01:18.968 DRIVER « [RES] [SendData] was sent: true 11:01:18.969 CNTRLR [Node 056] Interview stage completed: CommandClasses 11:01:18.970 CNTRLR [Node 056] Interview stage completed: OverwriteConfig 11:01:18.970 CNTRLR » [Node 056] requesting node neighbors... 11:01:19.098 SERIAL « 0x010700137100000e94 (9 bytes) 11:01:19.099 SERIAL » [ACK] (0x06) 11:01:19.122 DRIVER « [REQ] [SendData] callback id: 113 transmit status: OK 11:01:19.225 SERIAL « 0x010c000400150670066e027f1899 (14 bytes) 11:01:19.228 CNTRLR [Node 021] [~] [Configuration] 110: 32536 => 32536 11:01:19.229 SERIAL » [ACK] (0x06) 11:01:19.234 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 110 value size: 2 value: 32536 11:01:19.241 SERIAL » 0x010700803800000040 (9 bytes) 11:01:19.242 DRIVER » [Node 056] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 11:01:19.243 CNTRLR « [Node 021] parameter #110 has value: 32536 11:01:19.243 CNTRLR » [Node 021] querying parameter #120 value... 11:01:19.249 SERIAL « [ACK] (0x06) 11:01:19.251 SERIAL « 0x01200180012014000000000000000000000000000000000000000000000000000 (34 bytes) 06b 11:01:19.251 SERIAL » [ACK] (0x06) 11:01:19.252 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 14, 19, 21 11:01:19.257 SERIAL » 0x010a001315037005782572aa (12 bytes) 11:01:19.257 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 114 └─[ConfigurationCCGet] parameter #: 120 11:01:19.258 CNTRLR « [Node 056] node neighbors received: 1, 14, 19, 21 11:01:19.258 CNTRLR [Node 056] Interview stage completed: Neighbors 11:01:19.258 CNTRLR [Node 056] Interview completed 11:01:19.261 SERIAL « [ACK] (0x06) 11:01:19.266 DRIVER destroying driver instance...