09:28:29.683 DRIVER ███████╗ ██╗ ██╗ █████╗ ██╗ ██╗ ███████╗ ██╗ ███████╗ ╚══███╔╝ ██║ ██║ ██╔══██╗ ██║ ██║ ██╔════╝ ██║ ██╔════╝ ███╔╝ ██║ █╗ ██║ ███████║ ██║ ██║ █████╗ █████╗ ██║ ███████╗ ███╔╝ ██║███╗██║ ██╔══██║ ╚██╗ ██╔╝ ██╔══╝ ╚════╝ ██ ██║ ╚════██║ ███████╗ ╚███╔███╔╝ ██║ ██║ ╚████╔╝ ███████╗ ╚█████╔╝ ███████║ ╚══════╝ ╚══╝╚══╝ ╚═╝ ╚═╝ ╚═══╝ ╚══════╝ ╚════╝ ╚══════╝ 09:28:29.694 DRIVER version 5.3.1 09:28:29.695 DRIVER 09:28:29.696 DRIVER starting driver... 09:28:29.734 DRIVER opening serial port /dev/ttyACM1 09:28:29.821 DRIVER serial port opened 09:28:29.827 SERIAL » [NAK] (0x15) 09:28:29.843 SERIAL « 0x010c00040003063105042204fe1a (14 bytes) 09:28:29.849 DRIVER Dropping message because the driver is not ready to handle it yet. 09:28:29.850 SERIAL » [ACK] (0x06) 09:28:31.336 DRIVER loading configuration... 09:28:31.921 DRIVER beginning interview... 09:28:31.924 DRIVER added request handler for AddNodeToNetwork (0x4a)... 1 registered 09:28:31.925 DRIVER added request handler for RemoveNodeFromNetwork (0x4b)... 1 registered 09:28:31.927 CNTRLR beginning interview... 09:28:31.927 CNTRLR querying version info... 09:28:32.148 SERIAL » 0x01030015e9 (5 bytes) 09:28:32.149 DRIVER » [REQ] [GetControllerVersion] 09:28:32.153 SERIAL « [ACK] (0x06) 09:28:32.156 SERIAL « 0x011001155a2d5761766520342e3534000193 (18 bytes) 09:28:32.157 SERIAL » [ACK] (0x06) 09:28:32.159 DRIVER « [RES] [GetControllerVersion] payload: 0x5a2d5761766520342e35340001 09:28:32.168 CNTRLR received version info: controller type: Static Controller library version: Z-Wave 4.54 09:28:32.168 CNTRLR querying controller IDs... 09:28:32.176 SERIAL » 0x01030020dc (5 bytes) 09:28:32.177 DRIVER » [REQ] [GetControllerId] 09:28:32.179 SERIAL « [ACK] (0x06) 09:28:32.182 SERIAL « 0x01080120f314aee70179 (10 bytes) 09:28:32.183 SERIAL » [ACK] (0x06) 09:28:32.184 DRIVER « [RES] [GetControllerId] payload: 0xf314aee701 09:28:32.189 CNTRLR received controller IDs: home ID: 0xf314aee7 own node ID: 1 09:28:32.189 CNTRLR querying controller capabilities... 09:28:32.196 SERIAL » 0x01030005f9 (5 bytes) 09:28:32.197 DRIVER » [REQ] [GetControllerCapabilities] 09:28:32.199 SERIAL « [ACK] (0x06) 09:28:32.201 SERIAL « 0x0104010508f7 (6 bytes) 09:28:32.202 SERIAL » [ACK] (0x06) 09:28:32.203 DRIVER « [RES] [GetControllerCapabilities] payload: 0x08 09:28:32.208 CNTRLR received controller capabilities: controller role: primary is in other network: false is SIS present: false was real primary: true is a SUC: false 09:28:32.208 CNTRLR querying API capabilities... 09:28:32.215 SERIAL » 0x01030007fb (5 bytes) 09:28:32.215 DRIVER » [REQ] [GetSerialApiCapabilities] 09:28:32.217 SERIAL « [ACK] (0x06) 09:28:32.220 SERIAL « 0x012b0107010100860001005afe81ff884f1f0000fb9f7da067000080008086000 (45 bytes) 000e87300000e0000600000fa 09:28:32.221 SERIAL » [ACK] (0x06) 09:28:32.222 DRIVER « [RES] [GetSerialApiCapabilities] payload: 0x010100860001005afe81ff884f1f0000fb9f7da067000080008086000000e8730 0000e0000600000 09:28:32.228 CNTRLR received API capabilities: serial API version: 1.1 manufacturer ID: 0x86 product type: 0x01 product ID: 0x5a supported functions: · GetSerialApiInitData (0x02) · FUNC_ID_SERIAL_API_APPL_NODE_INFORMATION (0x03) · ApplicationCommand (0x04) · GetControllerCapabilities (0x05) · SetSerialApiTimeouts (0x06) · GetSerialApiCapabilities (0x07) · FUNC_ID_SERIAL_API_SOFT_RESET (0x08) · UNKNOWN_FUNC_UNKNOWN_0x09 (0x09) · UNKNOWN_FUNC_RF_RECEIVE_MODE (0x10) · UNKNOWN_FUNC_SET_SLEEP_MODE (0x11) · FUNC_ID_ZW_SEND_NODE_INFORMATION (0x12) · SendData (0x13) · SendDataMulticast (0x14) · GetControllerVersion (0x15) · SendDataAbort (0x16) · FUNC_ID_ZW_R_F_POWER_LEVEL_SET (0x17) · UNKNOWN_FUNC_SEND_DATA_META (0x18) · FUNC_ID_ZW_GET_RANDOM (0x1c) · GetControllerId (0x20) · UNKNOWN_FUNC_MEMORY_GET_BYTE (0x21) · UNKNOWN_FUNC_MEMORY_PUT_BYTE (0x22) · UNKNOWN_FUNC_MEMORY_GET_BUFFER (0x23) · UNKNOWN_FUNC_MEMORY_PUT_BUFFER (0x24) · UNKNOWN_FUNC_FlashAutoProgSet (0x27) · UNKNOWN_FUNC_NVMGetId (0x29) · UNKNOWN_FUNC_NVMExtReadLongBuffer (0x2a) · UNKNOWN_FUNC_NVMExtWriteLongBuffer (0x2b) · UNKNOWN_FUNC_NVMExtReadLongByte (0x2c) · UNKNOWN_FUNC_NVMExtWriteLongByte (0x2d) · GetNodeProtocolInfo (0x41) · HardReset (0x42) · FUNC_ID_ZW_REPLICATION_COMMAND_COMPLETE (0x44) · FUNC_ID_ZW_REPLICATION_SEND_DATA (0x45) · AssignReturnRoute (0x46) · DeleteReturnRoute (0x47) · RequestNodeNeighborUpdate (0x48) · ApplicationUpdateRequest (0x49) · AddNodeToNetwork (0x4a) · RemoveNodeFromNetwork (0x4b) · FUNC_ID_ZW_CREATE_NEW_PRIMARY (0x4c) · FUNC_ID_ZW_CONTROLLER_CHANGE (0x4d) · FUNC_ID_ZW_SET_LEARN_MODE (0x50) · FUNC_ID_ZW_ASSIGN_SUC_RETURN_ROUTE (0x51) · FUNC_ID_ZW_REQUEST_NETWORK_UPDATE (0x53) · FUNC_ID_ZW_SET_SUC_NODE_ID (0x54) · FUNC_ID_ZW_DELETE_SUC_RETURN_ROUTE (0x55) · GetSUCNodeId (0x56) · UNKNOWN_FUNC_SEND_SUC_ID (0x57) · FUNC_ID_ZW_EXPLORE_REQUEST_INCLUSION (0x5e) · RequestNodeInfo (0x60) · RemoveFailedNode (0x61) · IsFailedNode (0x62) · FUNC_ID_ZW_REPLACE_FAILED_NODE (0x63) · UNKNOWN_FUNC_UNKNOWN_0x66 (0x66) · UNKNOWN_FUNC_UNKNOWN_0x67 (0x67) · GetRoutingInfo (0x80) · UNKNOWN_FUNC_LOCK_ROUTE_RESPONSE (0x90) · UNKNOWN_FUNC_GET_PRIORITY_ROUTE (0x92) · UNKNOWN_FUNC_SET_PRIORITY_ROUTE (0x93) · UNKNOWN_FUNC_UNKNOWN_0x98 (0x98) · UNKNOWN_FUNC_UNKNOWN_0xB4 (0xb4) · UNKNOWN_FUNC_WATCH_DOG_ENABLE (0xb6) · UNKNOWN_FUNC_WATCH_DOG_DISABLE (0xb7) · UNKNOWN_FUNC_WATCH_DOG_KICK (0xb8) · UNKNOWN_FUNC_UNKNOWN_0xB9 (0xb9) · UNKNOWN_FUNC_RF_POWERLEVEL_GET (0xba) · UNKNOWN_FUNC_GET_LIBRARY_TYPE (0xbd) · UNKNOWN_FUNC_SEND_TEST_FRAME (0xbe) · UNKNOWN_FUNC_GET_PROTOCOL_STATUS (0xbf) · UNKNOWN_FUNC_UNKNOWN_0xD2 (0xd2) · UNKNOWN_FUNC_UNKNOWN_0xD3 (0xd3) · UNKNOWN_FUNC_UNKNOWN_0xD4 (0xd4) · undefined (0xee) · UNKNOWN_FUNC_UNKNOWN_0xEF (0xef) 09:28:32.229 CNTRLR finding SUC... 09:28:32.235 SERIAL » 0x01030056aa (5 bytes) 09:28:32.236 DRIVER » [REQ] [GetSUCNodeId] 09:28:32.238 SERIAL « [ACK] (0x06) 09:28:32.240 SERIAL « 0x0104015600ac (6 bytes) 09:28:32.240 SERIAL » [ACK] (0x06) 09:28:32.241 DRIVER « [RES] [GetSUCNodeId] payload: 0x00 09:28:32.246 CNTRLR no SUC present 09:28:32.760 CNTRLR querying node information... 09:28:32.773 SERIAL » 0x01030002fe (5 bytes) 09:28:32.774 DRIVER » [REQ] [GetSerialApiInitData] 09:28:32.776 SERIAL « [ACK] (0x06) 09:28:32.874 SERIAL « 0x0125010205001de7ffffff0700000000000000000000000000000000000000000 (39 bytes) 00000000500db 09:28:32.875 SERIAL » [ACK] (0x06) 09:28:32.876 DRIVER « [RES] [GetSerialApiInitData] payload: 0x05001de7ffffff070000000000000000000000000000000000000000000000000 500 09:28:32.880 CNTRLR received node information: controller role: primary controller is a SUC: false controller is a slave: false controller supports timers: false nodes in the network: 1, 2, 3, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35 09:28:32.972 DRIVER Cache file for homeId 0xf314aee7 found, attempting to restore the network from cache... 09:28:32.987 CNTRLR [Node 001] trying to load device config 09:28:33.001 CNTRLR [Node 001] device config loaded 09:28:33.003 CNTRLR [Node 002] trying to load device config 09:28:33.035 CNTRLR [Node 002] device config loaded 09:28:33.037 CNTRLR [Node 003] trying to load device config 09:28:33.050 CNTRLR [Node 003] device config loaded 09:28:33.054 CNTRLR [Node 006] trying to load device config 09:28:33.061 CNTRLR [Node 006] device config loaded 09:28:33.062 CNTRLR [Node 007] trying to load device config 09:28:33.079 CNTRLR [Node 007] device config loaded 09:28:33.080 CNTRLR [Node 008] trying to load device config 09:28:33.093 CNTRLR [Node 008] device config loaded 09:28:33.094 CNTRLR [Node 009] trying to load device config 09:28:33.111 CNTRLR [Node 009] device config loaded 09:28:33.113 CNTRLR [Node 010] trying to load device config 09:28:33.123 CNTRLR [Node 010] device config loaded 09:28:33.124 CNTRLR [Node 011] trying to load device config 09:28:33.128 CNTRLR [Node 011] device config loaded 09:28:33.129 CNTRLR [Node 012] trying to load device config 09:28:33.140 CNTRLR [Node 012] device config loaded 09:28:33.141 CNTRLR [Node 013] trying to load device config 09:28:33.158 CNTRLR [Node 013] device config loaded 09:28:33.160 CNTRLR [Node 014] trying to load device config 09:28:33.171 CNTRLR [Node 014] device config loaded 09:28:33.173 CNTRLR [Node 015] trying to load device config 09:28:33.186 CNTRLR [Node 015] device config loaded 09:28:33.187 CNTRLR [Node 016] trying to load device config 09:28:33.201 CNTRLR [Node 016] device config loaded 09:28:33.202 CNTRLR [Node 017] trying to load device config 09:28:33.215 CNTRLR [Node 017] device config loaded 09:28:33.218 CNTRLR [Node 018] trying to load device config 09:28:33.222 CNTRLR [Node 018] device config loaded 09:28:33.223 CNTRLR [Node 019] trying to load device config 09:28:33.235 CNTRLR [Node 019] device config loaded 09:28:33.236 CNTRLR [Node 020] trying to load device config 09:28:33.247 CNTRLR [Node 020] device config loaded 09:28:33.248 CNTRLR [Node 021] trying to load device config 09:28:33.262 CNTRLR [Node 021] device config loaded 09:28:33.264 CNTRLR [Node 022] trying to load device config 09:28:33.268 CNTRLR [Node 022] device config loaded 09:28:33.270 CNTRLR [Node 023] trying to load device config 09:28:33.286 CNTRLR [Node 023] device config loaded 09:28:33.288 CNTRLR [Node 024] trying to load device config 09:28:33.308 CNTRLR [Node 024] device config loaded 09:28:33.310 CNTRLR [Node 025] trying to load device config 09:28:33.323 CNTRLR [Node 025] device config loaded 09:28:33.324 CNTRLR [Node 026] trying to load device config 09:28:33.333 CNTRLR [Node 026] device config loaded 09:28:33.334 CNTRLR [Node 027] trying to load device config 09:28:33.346 CNTRLR [Node 027] device config loaded 09:28:33.348 CNTRLR [Node 028] trying to load device config 09:28:33.352 CNTRLR [Node 028] device config loaded 09:28:33.354 CNTRLR [Node 029] trying to load device config 09:28:33.358 CNTRLR [Node 029] device config loaded 09:28:33.359 CNTRLR [Node 030] trying to load device config 09:28:33.371 CNTRLR [Node 030] device config loaded 09:28:33.372 CNTRLR [Node 031] trying to load device config 09:28:33.384 CNTRLR [Node 031] device config loaded 09:28:33.385 CNTRLR [Node 032] trying to load device config 09:28:33.396 CNTRLR [Node 032] device config loaded 09:28:33.398 CNTRLR [Node 033] trying to load device config 09:28:33.407 CNTRLR [Node 033] device config loaded 09:28:33.408 CNTRLR [Node 034] trying to load device config 09:28:33.427 CNTRLR [Node 034] device config loaded 09:28:33.429 CNTRLR [Node 035] trying to load device config 09:28:33.433 CNTRLR [Node 035] device config loaded 09:28:33.434 DRIVER Restoring the network from cache was successful! 09:28:33.438 CNTRLR [Node 001] [Manufacturer Specific] manufacturerId: metadata updated 09:28:33.439 CNTRLR [Node 001] [Manufacturer Specific] productType: metadata updated 09:28:33.440 CNTRLR [Node 001] [Manufacturer Specific] productId: metadata updated 09:28:33.442 CNTRLR [Node 001] [~] [Manufacturer Specific] manufacturerId: 134 => 134 09:28:33.443 CNTRLR [Node 001] [~] [Manufacturer Specific] productType: 1 => 1 09:28:33.444 CNTRLR [Node 001] [~] [Manufacturer Specific] productId: 90 => 90 09:28:33.444 CNTRLR setting serial API timeouts: ack = 1000 ms, byte = 150 ms 09:28:33.451 SERIAL » 0x01050006640f97 (7 bytes) 09:28:33.451 DRIVER » [REQ] [SetSerialApiTimeouts] payload: 0x640f 09:28:33.454 SERIAL « [ACK] (0x06) 09:28:33.456 SERIAL « 0x01050106640f96 (7 bytes) 09:28:33.457 SERIAL » [ACK] (0x06) 09:28:33.458 DRIVER « [RES] [SetSerialApiTimeouts] payload: 0x640f 09:28:33.465 CNTRLR serial API timeouts overwritten. The old values were: ack = 1000 ms, byte = 15 0 ms 09:28:33.465 CNTRLR Interview completed 09:28:33.468 DRIVER driver ready 09:28:33.475 CNTRLR [Node 001] Beginning interview - last completed stage: RestartFromCache 09:28:33.477 CNTRLR [Node 001] not pinging the controller 09:28:33.547 CNTRLR [Node 001] Interview stage completed: CommandClasses 09:28:33.548 CNTRLR [Node 001] trying to load device config 09:28:33.552 CNTRLR [Node 001] device config loaded 09:28:33.553 CNTRLR [Node 001] Interview stage completed: OverwriteConfig 09:28:33.554 CNTRLR » [Node 001] requesting node neighbors... 09:28:33.627 SERIAL » 0x010700800100000079 (9 bytes) 09:28:33.628 DRIVER » [Node 001] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:28:33.636 SERIAL « [ACK] (0x06) 09:28:33.638 SERIAL « 0x01200180e4fffd6f0700000000000000000000000000000000000000000000000 (34 bytes) 0d0 09:28:33.639 SERIAL » [ACK] (0x06) 09:28:33.641 DRIVER « [RES] [GetRoutingInfo] node ids: 3, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 30, 31, 33, 34, 35 09:28:33.647 CNTRLR [Node 001] The node is alive. 09:28:33.648 CNTRLR [Node 001] The node is ready to be used 09:28:33.649 CNTRLR « [Node 001] node neighbors received: 3, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 1 6, 17, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 30, 31, 33, 34, 35 09:28:33.650 CNTRLR [Node 001] Interview stage completed: Neighbors 09:28:33.650 CNTRLR [Node 001] Interview completed 09:28:33.652 CNTRLR [Node 002] Beginning interview - last completed stage: RestartFromCache 09:28:33.653 CNTRLR » [Node 002] pinging the node... 09:28:33.668 SERIAL » 0x010800130201002501c3 (10 bytes) 09:28:33.669 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 1 └─[NoOperationCC] 09:28:33.670 CNTRLR [Node 003] Beginning interview - last completed stage: RestartFromCache 09:28:33.672 CNTRLR » [Node 003] pinging the node... 09:28:33.675 CNTRLR [Node 006] Beginning interview - last completed stage: RestartFromCache 09:28:33.676 CNTRLR » [Node 006] pinging the node... 09:28:33.680 CNTRLR [Node 007] Beginning interview - last completed stage: RestartFromCache 09:28:33.680 CNTRLR » [Node 007] pinging the node... 09:28:33.683 CNTRLR [Node 008] Beginning interview - last completed stage: RestartFromCache 09:28:33.684 CNTRLR » [Node 008] pinging the node... 09:28:33.687 CNTRLR [Node 009] Beginning interview - last completed stage: RestartFromCache 09:28:33.688 CNTRLR » [Node 009] pinging the node... 09:28:33.690 CNTRLR [Node 010] Beginning interview - last completed stage: RestartFromCache 09:28:33.691 CNTRLR » [Node 010] pinging the node... 09:28:33.694 CNTRLR [Node 011] Beginning interview - last completed stage: RestartFromCache 09:28:33.695 CNTRLR » [Node 011] pinging the node... 09:28:33.697 CNTRLR [Node 012] Beginning interview - last completed stage: RestartFromCache 09:28:33.698 CNTRLR » [Node 012] pinging the node... 09:28:33.701 CNTRLR [Node 013] Beginning interview - last completed stage: RestartFromCache 09:28:33.701 CNTRLR » [Node 013] pinging the node... 09:28:33.704 CNTRLR [Node 014] Beginning interview - last completed stage: RestartFromCache 09:28:33.705 CNTRLR » [Node 014] pinging the node... 09:28:33.707 CNTRLR [Node 015] Beginning interview - last completed stage: RestartFromCache 09:28:33.708 CNTRLR » [Node 015] pinging the node... 09:28:33.711 CNTRLR [Node 016] Beginning interview - last completed stage: RestartFromCache 09:28:33.711 CNTRLR » [Node 016] pinging the node... 09:28:33.714 CNTRLR [Node 017] Beginning interview - last completed stage: RestartFromCache 09:28:33.715 CNTRLR » [Node 017] pinging the node... 09:28:33.717 CNTRLR [Node 018] Beginning interview - last completed stage: RestartFromCache 09:28:33.718 CNTRLR » [Node 018] pinging the node... 09:28:33.720 CNTRLR [Node 019] Beginning interview - last completed stage: RestartFromCache 09:28:33.721 CNTRLR » [Node 019] pinging the node... 09:28:33.724 CNTRLR [Node 020] Beginning interview - last completed stage: RestartFromCache 09:28:33.725 CNTRLR » [Node 020] pinging the node... 09:28:33.727 CNTRLR [Node 021] Beginning interview - last completed stage: RestartFromCache 09:28:33.728 CNTRLR » [Node 021] pinging the node... 09:28:33.731 CNTRLR [Node 022] Beginning interview - last completed stage: RestartFromCache 09:28:33.732 CNTRLR » [Node 022] pinging the node... 09:28:33.734 CNTRLR [Node 023] Beginning interview - last completed stage: RestartFromCache 09:28:33.735 CNTRLR » [Node 023] pinging the node... 09:28:33.738 CNTRLR [Node 024] Beginning interview - last completed stage: RestartFromCache 09:28:33.738 CNTRLR » [Node 024] pinging the node... 09:28:33.741 CNTRLR [Node 025] Beginning interview - last completed stage: RestartFromCache 09:28:33.742 CNTRLR » [Node 025] pinging the node... 09:28:33.744 CNTRLR [Node 026] Beginning interview - last completed stage: RestartFromCache 09:28:33.745 CNTRLR » [Node 026] pinging the node... 09:28:33.748 CNTRLR [Node 027] Beginning interview - last completed stage: RestartFromCache 09:28:33.748 CNTRLR » [Node 027] pinging the node... 09:28:33.751 CNTRLR [Node 028] Beginning interview - last completed stage: RestartFromCache 09:28:33.752 CNTRLR » [Node 028] pinging the node... 09:28:33.754 CNTRLR [Node 029] Beginning interview - last completed stage: RestartFromCache 09:28:33.755 CNTRLR » [Node 029] pinging the node... 09:28:33.758 CNTRLR [Node 030] Beginning interview - last completed stage: RestartFromCache 09:28:33.759 CNTRLR » [Node 030] pinging the node... 09:28:33.761 CNTRLR [Node 031] Beginning interview - last completed stage: RestartFromCache 09:28:33.762 CNTRLR » [Node 031] pinging the node... 09:28:33.764 CNTRLR [Node 032] Beginning interview - last completed stage: RestartFromCache 09:28:33.765 CNTRLR » [Node 032] pinging the node... 09:28:33.768 CNTRLR [Node 033] Beginning interview - last completed stage: RestartFromCache 09:28:33.769 CNTRLR » [Node 033] pinging the node... 09:28:33.771 CNTRLR [Node 034] Beginning interview - last completed stage: RestartFromCache 09:28:33.772 CNTRLR » [Node 034] pinging the node... 09:28:33.774 CNTRLR [Node 035] Beginning interview - last completed stage: RestartFromCache 09:28:33.775 CNTRLR » [Node 035] pinging the node... 09:28:33.798 SERIAL « [ACK] (0x06) 09:28:33.801 SERIAL « 0x0104011301e8 (6 bytes) 09:28:33.802 SERIAL » [ACK] (0x06) 09:28:33.805 DRIVER « [RES] [SendData] was sent: true 09:28:37.918 SERIAL « 0x010700130101019d77 (9 bytes) 09:28:37.919 SERIAL » [ACK] (0x06) 09:28:37.922 DRIVER « [REQ] [SendData] callback id: 1 transmit status: NoAck 09:28:37.949 SERIAL » 0x010800130301002502c1 (10 bytes) 09:28:37.950 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 2 └─[NoOperationCC] 09:28:37.951 CNTRLR [Node 002] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 09:28:37.953 CNTRLR [Node 002] The node is asleep. 09:28:37.957 CNTRLR [Node 002] The node is ready to be used 09:28:37.959 CNTRLR [Node 002] ping failed: Failed to send the command after 1 attempts (Status No Ack) 09:28:37.972 CNTRLR [Node 002] ManufacturerSpecificCC: doing a partial interview... 09:28:37.974 CNTRLR [Node 002] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:28:38.042 SERIAL « [ACK] (0x06) 09:28:38.046 SERIAL « 0x0104011301e8 (6 bytes) 09:28:38.047 SERIAL » [ACK] (0x06) 09:28:38.051 DRIVER « [RES] [SendData] was sent: true 09:28:38.060 CNTRLR [Node 002] VersionCC: doing a partial interview... 09:28:38.061 CNTRLR [Node 002] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:28:38.061 CNTRLR [Node 002] trying to load device config 09:28:38.065 SERIAL « 0x0107001302000008e1 (9 bytes) 09:28:38.066 SERIAL » [ACK] (0x06) 09:28:38.068 DRIVER « [REQ] [SendData] callback id: 2 transmit status: OK 09:28:38.078 SERIAL » 0x010800130601002503c5 (10 bytes) 09:28:38.079 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 3 └─[NoOperationCC] 09:28:38.079 CNTRLR « [Node 003] ping successful 09:28:38.083 CNTRLR [Node 003] ManufacturerSpecificCC: doing a partial interview... 09:28:38.084 CNTRLR [Node 003] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:28:38.085 CNTRLR [Node 003] VersionCC: doing a partial interview... 09:28:38.086 CNTRLR [Node 003] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:28:38.086 CNTRLR [Node 003] trying to load device config 09:28:38.091 SERIAL « [ACK] (0x06) 09:28:38.092 SERIAL « 0x0104011301e8 (6 bytes) 09:28:38.093 SERIAL » [ACK] (0x06) 09:28:38.107 CNTRLR [Node 002] device config loaded 09:28:38.109 CNTRLR [Node 002] ZWavePlusCC: doing a partial interview... 09:28:38.110 CNTRLR [Node 002] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:28:38.111 CNTRLR [Node 002] BatteryCC: doing a partial interview... 09:28:38.112 CNTRLR » [Node 002] querying battery status... 09:28:38.127 DRIVER « [RES] [SendData] was sent: true 09:28:38.138 CNTRLR [Node 003] device config loaded 09:28:38.140 CNTRLR [Node 003] AssociationCC: doing a partial interview... 09:28:38.141 CNTRLR [Node 003] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 09:28:38.142 CNTRLR [Node 003] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:28:38.143 CNTRLR [Node 003] BinarySwitchCC: doing a partial interview... 09:28:38.143 CNTRLR » [Node 003] querying Binary Switch state... 09:28:39.474 SERIAL « 0x010700130300008b63 (9 bytes) 09:28:39.475 SERIAL » [ACK] (0x06) 09:28:39.476 DRIVER « [REQ] [SendData] callback id: 3 transmit status: OK 09:28:39.486 SERIAL » 0x010800130701002504c3 (10 bytes) 09:28:39.487 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 4 └─[NoOperationCC] 09:28:39.487 CNTRLR « [Node 006] ping successful 09:28:39.533 SERIAL « [ACK] (0x06) 09:28:39.538 SERIAL « 0x0104011301e8 (6 bytes) 09:28:39.539 SERIAL » [ACK] (0x06) 09:28:39.541 DRIVER « [RES] [SendData] was sent: true 09:28:39.548 CNTRLR [Node 006] ManufacturerSpecificCC: doing a partial interview... 09:28:39.549 CNTRLR [Node 006] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:28:39.550 CNTRLR [Node 006] VersionCC: doing a partial interview... 09:28:39.550 CNTRLR [Node 006] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:28:39.551 CNTRLR [Node 006] trying to load device config 09:28:39.552 SERIAL « 0x0107001304000003ec (9 bytes) 09:28:39.553 SERIAL » [ACK] (0x06) 09:28:39.554 DRIVER « [REQ] [SendData] callback id: 4 transmit status: OK 09:28:39.561 SERIAL » 0x01090013030225022505e3 (11 bytes) 09:28:39.561 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 5 └─[BinarySwitchCCGet] 09:28:39.562 CNTRLR « [Node 007] ping successful 09:28:39.564 CNTRLR [Node 007] ManufacturerSpecificCC: doing a partial interview... 09:28:39.565 CNTRLR [Node 007] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:28:39.565 CNTRLR [Node 007] VersionCC: doing a partial interview... 09:28:39.566 CNTRLR [Node 007] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:28:39.566 CNTRLR [Node 007] trying to load device config 09:28:39.569 SERIAL « [ACK] (0x06) 09:28:39.572 CNTRLR [Node 006] device config loaded 09:28:39.573 CNTRLR [Node 006] ZWavePlusCC: doing a partial interview... 09:28:39.573 CNTRLR [Node 006] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:28:39.575 CNTRLR » [Node 006] querying device endpoint information... 09:28:39.592 SERIAL « 0x0104011301e8 (6 bytes) 09:28:39.593 SERIAL » [ACK] (0x06) 09:28:39.593 DRIVER « [RES] [SendData] was sent: true 09:28:39.608 CNTRLR [Node 007] device config loaded 09:28:39.609 CNTRLR [Node 007] ZWavePlusCC: doing a partial interview... 09:28:39.610 CNTRLR [Node 007] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:28:39.610 CNTRLR [Node 007] BatteryCC: doing a partial interview... 09:28:39.611 CNTRLR » [Node 007] querying battery status... 09:28:39.648 SERIAL « 0x0107001305000008e6 (9 bytes) 09:28:39.648 SERIAL » [ACK] (0x06) 09:28:39.649 DRIVER « [REQ] [SendData] callback id: 5 transmit status: OK 09:28:39.728 SERIAL « 0x010900040003032503ff2b (11 bytes) 09:28:39.730 CNTRLR [Node 003] [~] [Binary Switch] currentValue: true => true [Endpoint 0] 09:28:39.731 SERIAL » [ACK] (0x06) 09:28:39.736 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: true 09:28:39.764 SERIAL » 0x0109001307028002250641 (11 bytes) 09:28:39.765 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 6 └─[BatteryCCGet] 09:28:39.769 CNTRLR [Node 003] The node is alive. 09:28:39.770 CNTRLR [Node 003] The node is ready to be used 09:28:39.773 CNTRLR « [Node 003] received Binary Switch state: current value: true 09:28:39.773 CNTRLR [Node 003] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 09:28:39.775 CNTRLR [Node 003] MultilevelSensorCC: doing a partial interview... 09:28:39.775 CNTRLR » [Node 003] querying current sensor reading... 09:28:39.790 SERIAL « [ACK] (0x06) 09:28:39.792 SERIAL « 0x0104011301e8 (6 bytes) 09:28:39.792 SERIAL » [ACK] (0x06) 09:28:39.796 DRIVER « [RES] [SendData] was sent: true 09:28:39.810 SERIAL « 0x0107001306000004e9 (9 bytes) 09:28:39.810 SERIAL » [ACK] (0x06) 09:28:39.811 DRIVER « [REQ] [SendData] callback id: 6 transmit status: OK 09:28:41.179 SERIAL « 0x0109000400070380036411 (11 bytes) 09:28:41.183 CNTRLR [Node 007] [~] [Battery] level: 100 => 100 [Endpoint 0] 09:28:41.185 CNTRLR [Node 007] [~] [Battery] isLow: false => false [Endpoint 0] 09:28:41.186 SERIAL » [ACK] (0x06) 09:28:41.190 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 09:28:41.262 SERIAL » 0x010900130602984025071b (11 bytes) 09:28:41.263 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 7 └─[SecurityCCNonceGet] 09:28:41.266 CNTRLR « [Node 007] received response for battery information: level: 100 09:28:41.267 CNTRLR [Node 007] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:28:41.303 SERIAL « [ACK] (0x06) 09:28:41.315 SERIAL « 0x0104011301e8 (6 bytes) 09:28:41.316 SERIAL » [ACK] (0x06) 09:28:41.319 DRIVER « [RES] [SendData] was sent: true 09:28:41.323 CNTRLR [Node 007] WakeUpCC: doing a partial interview... 09:28:41.323 CNTRLR » [Node 007] retrieving wakeup interval from the device... 09:28:41.332 SERIAL « 0x0107001307000007eb (9 bytes) 09:28:41.332 SERIAL » [ACK] (0x06) 09:28:41.333 DRIVER « [REQ] [SendData] callback id: 7 transmit status: OK 09:28:41.417 SERIAL « 0x0110000400060a9880d8dfcd23ad08a9a6bc (18 bytes) 09:28:41.418 SERIAL » [ACK] (0x06) 09:28:41.419 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xd8dfcd23ad08a9a6 09:28:41.421 CNTRLR [Node 006] The node is alive. 09:28:41.422 CNTRLR [Node 006] The node is ready to be used 09:28:41.430 SERIAL » 0x011d001306169881d381a80728b7a4e2a8c4dfd819ec00870f8e9eb4250843 (31 bytes) 09:28:41.431 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 8 └─[SecurityCCCommandEncapsulation] │ nonce id: 216 └─[MultiChannelCCEndPointGet] 09:28:41.437 SERIAL « [ACK] (0x06) 09:28:41.443 SERIAL « 0x0104011301e8 (6 bytes) 09:28:41.443 SERIAL » [ACK] (0x06) 09:28:41.444 DRIVER « [RES] [SendData] was sent: true 09:28:42.199 SERIAL « 0x010700130800000cef (9 bytes) 09:28:42.199 SERIAL » [ACK] (0x06) 09:28:42.201 DRIVER « [REQ] [SendData] callback id: 8 transmit status: OK 09:28:42.205 SERIAL « 0x0108000400060298402f (10 bytes) 09:28:42.206 SERIAL » [ACK] (0x06) 09:28:42.206 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:28:42.224 SERIAL » 0x01110013060a98808fc9304bd78369a5240068 (19 bytes) 09:28:42.224 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x8fc9304bd78369a5 09:28:42.228 SERIAL « [ACK] (0x06) 09:28:42.233 SERIAL « 0x0104011301e8 (6 bytes) 09:28:42.234 SERIAL » [ACK] (0x06) 09:28:42.235 DRIVER « [RES] [SendData] was sent: true 09:28:42.395 SERIAL « 0x011f0004000619988139c0e1dd0e95fc37f5efe1d747b18fab42e500577716485 (33 bytes) 0 09:28:42.397 SERIAL » [ACK] (0x06) 09:28:42.399 CNTRLR [Node 006] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:28:42.400 CNTRLR [Node 006] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 09:28:42.401 CNTRLR [Node 006] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:28:42.401 CNTRLR [Node 006] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 09:28:42.402 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:28:42.408 SERIAL » 0x010900130702840525094d (11 bytes) 09:28:42.408 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 9 └─[WakeUpCCIntervalGet] 09:28:42.409 CNTRLR « [Node 006] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:28:42.410 CNTRLR » [Node 006] querying all endpoints... 09:28:42.417 SERIAL « [ACK] (0x06) 09:28:42.419 SERIAL « 0x0104011301e8 (6 bytes) 09:28:42.419 SERIAL » [ACK] (0x06) 09:28:42.421 DRIVER « [RES] [SendData] was sent: true 09:28:42.490 SERIAL « 0x0107001309000007e5 (9 bytes) 09:28:42.490 SERIAL » [ACK] (0x06) 09:28:42.491 DRIVER « [REQ] [SendData] callback id: 9 transmit status: OK 09:28:42.504 SERIAL « 0x010c00040007068406000e10016b (14 bytes) 09:28:42.506 CNTRLR [Node 007] [~] [Wake Up] wakeUpInterval: 3600 => 3600 [Endpoint 0] 09:28:42.507 CNTRLR [Node 007] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 09:28:42.507 SERIAL » [ACK] (0x06) 09:28:42.509 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 3600 seconds controller node id: 1 09:28:42.515 SERIAL » 0x0109001303023104250afe (11 bytes) 09:28:42.515 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 10 └─[MultilevelSensorCCGet] 09:28:42.516 CNTRLR « [Node 007] received wakeup configuration: wakeup interval: 3600 seconds controller node: 1 09:28:42.517 CNTRLR [Node 007] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:28:42.552 SERIAL « [ACK] (0x06) 09:28:42.557 SERIAL « 0x0104011301e8 (6 bytes) 09:28:42.557 SERIAL » [ACK] (0x06) 09:28:42.560 DRIVER « [RES] [SendData] was sent: true 09:28:42.564 CNTRLR [Node 007] BasicCC: doing a partial interview... 09:28:42.564 CNTRLR » [Node 007] querying Basic CC state... 09:28:42.603 SERIAL « 0x010700130a000009e8 (9 bytes) 09:28:42.604 SERIAL » [ACK] (0x06) 09:28:42.604 DRIVER « [REQ] [SendData] callback id: 10 transmit status: OK 09:28:42.676 SERIAL « 0x010c00040003063105042204b450 (14 bytes) 09:28:42.677 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:28:42.678 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 213.6 => 120.4 [Endpoint 0] 09:28:42.679 SERIAL » [ACK] (0x06) 09:28:42.681 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 120.4 09:28:42.686 SERIAL » 0x0109001307022002250bec (11 bytes) 09:28:42.687 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 11 └─[BasicCCGet] 09:28:42.687 CNTRLR « [Node 003] received current sensor reading: sensor type: Power value: 120.4 W 09:28:42.688 CNTRLR [Node 003] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 09:28:42.689 CNTRLR [Node 003] MeterCC: doing a partial interview... 09:28:42.690 CNTRLR » [Node 003] querying default meter value... 09:28:42.706 SERIAL « [ACK] (0x06) 09:28:42.708 SERIAL « 0x0104011301e8 (6 bytes) 09:28:42.708 SERIAL » [ACK] (0x06) 09:28:42.709 DRIVER « [RES] [SendData] was sent: true 09:28:42.725 SERIAL « 0x010700130b000004e4 (9 bytes) 09:28:42.725 SERIAL » [ACK] (0x06) 09:28:42.726 DRIVER « [REQ] [SendData] callback id: 11 transmit status: OK 09:28:42.738 SERIAL « 0x01090004000703200300d5 (11 bytes) 09:28:42.739 SERIAL » [ACK] (0x06) 09:28:42.740 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BasicCCReport] current value: 0 09:28:42.751 SERIAL » 0x0109001306029840250c10 (11 bytes) 09:28:42.752 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 12 └─[SecurityCCNonceGet] 09:28:42.753 CNTRLR « [Node 007] received Basic CC state: current value: 0 09:28:42.754 CNTRLR [Node 007] [~] [Basic] interviewComplete: true => true [Endpoint 0] [internal] 09:28:42.787 SERIAL « [ACK] (0x06) 09:28:42.791 SERIAL « 0x0104011301e8 (6 bytes) 09:28:42.791 SERIAL » [ACK] (0x06) 09:28:42.792 DRIVER « [RES] [SendData] was sent: true 09:28:42.796 CNTRLR [Node 007] BinarySensorCC: doing a partial interview... 09:28:42.797 CNTRLR » [Node 007] querying current value... 09:28:44.166 SERIAL « 0x010700130c00008d6a (9 bytes) 09:28:44.167 SERIAL » [ACK] (0x06) 09:28:44.168 DRIVER « [REQ] [SendData] callback id: 12 transmit status: OK 09:28:44.254 SERIAL « 0x0110000400060a988059e64541c2ab505e23 (18 bytes) 09:28:44.255 SERIAL » [ACK] (0x06) 09:28:44.256 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x59e64541c2ab505e 09:28:44.264 SERIAL » 0x011f001306189881662e1f05013cffe9535ba8f29359e2a564517cd0c78d250da (33 bytes) 9 09:28:44.265 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 13 └─[SecurityCCCommandEncapsulation] │ nonce id: 89 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:28:44.269 SERIAL « [ACK] (0x06) 09:28:44.276 SERIAL « 0x0104011301e8 (6 bytes) 09:28:44.276 SERIAL » [ACK] (0x06) 09:28:44.277 DRIVER « [RES] [SendData] was sent: true 09:28:44.399 SERIAL « 0x010700130d00000cea (9 bytes) 09:28:44.399 SERIAL » [ACK] (0x06) 09:28:44.400 DRIVER « [REQ] [SendData] callback id: 13 transmit status: OK 09:28:44.480 SERIAL « 0x0108000400060298402f (10 bytes) 09:28:44.481 SERIAL » [ACK] (0x06) 09:28:44.482 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:28:44.495 SERIAL » 0x01110013060a9880bfc4866e28d5ad97240099 (19 bytes) 09:28:44.495 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xbfc4866e28d5ad97 09:28:44.499 SERIAL « [ACK] (0x06) 09:28:44.505 SERIAL « 0x0104011301e8 (6 bytes) 09:28:44.506 SERIAL » [ACK] (0x06) 09:28:44.507 DRIVER « [RES] [SendData] was sent: true 09:28:44.712 SERIAL « 0x0121000400061b98818e04933edea4fc244ed9884e46fd7093bfde48910506688 (35 bytes) 2181b 09:28:44.714 SERIAL » [ACK] (0x06) 09:28:44.716 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 09:28:44.729 SERIAL » 0x0109001307023002250ef9 (11 bytes) 09:28:44.730 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 14 └─[BinarySensorCCGet] type: Any 09:28:44.731 CNTRLR « [Node 006] received endpoints: 1, 2 09:28:44.731 CNTRLR » [Node 006] querying capabilities for endpoint #1... 09:28:44.736 SERIAL « [ACK] (0x06) 09:28:44.738 SERIAL « 0x0104011301e8 (6 bytes) 09:28:44.739 SERIAL » [ACK] (0x06) 09:28:44.740 DRIVER « [RES] [SendData] was sent: true 09:28:44.800 SERIAL « 0x010700130e000006e3 (9 bytes) 09:28:44.800 SERIAL » [ACK] (0x06) 09:28:44.801 DRIVER « [REQ] [SendData] callback id: 14 transmit status: OK 09:28:44.813 SERIAL « 0x01090004000703300300c5 (11 bytes) 09:28:44.815 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:28:44.816 CNTRLR [Node 007] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:28:44.817 SERIAL » [ACK] (0x06) 09:28:44.819 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:28:44.826 SERIAL » 0x0109001303023201250ffd (11 bytes) 09:28:44.827 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 15 └─[MeterCCGet] 09:28:44.828 CNTRLR « [Node 007] received current value: false 09:28:44.829 CNTRLR [Node 007] [~] [Binary Sensor] interviewComplete: true [Endpoint 0] [internal] => true 09:28:44.857 SERIAL « [ACK] (0x06) 09:28:44.862 SERIAL « 0x0104011301e8 (6 bytes) 09:28:44.862 SERIAL » [ACK] (0x06) 09:28:44.865 DRIVER « [RES] [SendData] was sent: true 09:28:44.868 CNTRLR [Node 007] MultilevelSensorCC: doing a partial interview... 09:28:44.868 CNTRLR » [Node 007] querying current sensor reading... 09:28:44.915 SERIAL « 0x010700130f000008ec (9 bytes) 09:28:44.915 SERIAL » [ACK] (0x06) 09:28:44.916 DRIVER « [REQ] [SendData] callback id: 15 transmit status: OK 09:28:44.990 SERIAL « 0x010e00040003083202014400001ef762 (16 bytes) 09:28:44.993 CNTRLR [Node 003] [~] [Meter] value[65536]: 79.11 => 79.27 [Endpoint 0] 09:28:44.994 CNTRLR [Node 003] [~] [Meter] deltaTime[65536]: 0 => 0 [Endpoint 0] 09:28:44.994 SERIAL » [ACK] (0x06) 09:28:44.996 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Unspecified value: 79.27 time delta: 0 seconds 09:28:45.002 SERIAL » 0x01090013070231042510e0 (11 bytes) 09:28:45.002 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[MultilevelSensorCCGet] 09:28:45.005 CNTRLR [Node 003] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 09:28:45.006 CNTRLR [Node 003] ConfigurationCC: Loading configuration parameters from device confi g 09:28:45.013 CNTRLR [Node 003] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:28:45.016 CNTRLR [Node 003] [Configuration] 1: metadata updated 09:28:45.018 CNTRLR [Node 003] [Configuration] 16: metadata updated 09:28:45.019 CNTRLR [Node 003] [Configuration] 34: metadata updated 09:28:45.021 CNTRLR [Node 003] [Configuration] 35: metadata updated 09:28:45.023 CNTRLR [Node 003] [Configuration] 39: metadata updated 09:28:45.024 CNTRLR [Node 003] [Configuration] 40: metadata updated 09:28:45.026 CNTRLR [Node 003] [Configuration] 42: metadata updated 09:28:45.028 CNTRLR [Node 003] [Configuration] 43: metadata updated 09:28:45.029 CNTRLR [Node 003] [Configuration] 45: metadata updated 09:28:45.030 CNTRLR [Node 003] [Configuration] 47: metadata updated 09:28:45.032 CNTRLR [Node 003] [Configuration] 49: metadata updated 09:28:45.033 CNTRLR [Node 003] [Configuration] 50: metadata updated 09:28:45.035 CNTRLR [Node 003] [Configuration] 51: metadata updated 09:28:45.036 CNTRLR [Node 003] [Configuration] 52: metadata updated 09:28:45.037 CNTRLR [Node 003] [Configuration] 60: metadata updated 09:28:45.039 CNTRLR [Node 003] [Configuration] 61: metadata updated 09:28:45.040 CNTRLR [Node 003] [Configuration] 62: metadata updated 09:28:45.042 CNTRLR [Node 003] [Configuration] 63: metadata updated 09:28:45.043 CNTRLR [Node 003] [Configuration] 70: metadata updated 09:28:45.044 CNTRLR [Node 003] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:28:45.045 CNTRLR » [Node 003] querying parameter #1 value... 09:28:45.075 SERIAL « [ACK] (0x06) 09:28:45.077 SERIAL « 0x0104011301e8 (6 bytes) 09:28:45.077 SERIAL » [ACK] (0x06) 09:28:45.081 DRIVER « [RES] [SendData] was sent: true 09:28:45.109 SERIAL « 0x0107001310000009f2 (9 bytes) 09:28:45.110 SERIAL » [ACK] (0x06) 09:28:45.113 DRIVER « [REQ] [SendData] callback id: 16 transmit status: OK 09:28:45.540 SERIAL « 0x010c00040007063105012200cb2a (14 bytes) 09:28:45.542 CNTRLR [Node 007] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 09:28:45.544 CNTRLR [Node 007] [~] [Multilevel Sensor] Air temperature: 20.6 => 20.3 [Endpoint 0] 09:28:45.545 SERIAL » [ACK] (0x06) 09:28:45.548 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 20.3 09:28:45.564 SERIAL » 0x010900130602984025110d (11 bytes) 09:28:45.565 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 17 └─[SecurityCCNonceGet] 09:28:45.567 CNTRLR « [Node 007] received current sensor reading: sensor type: Air temperature value: 20.3 °C 09:28:45.568 CNTRLR [Node 007] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 09:28:45.623 SERIAL « [ACK] (0x06) 09:28:45.630 SERIAL « 0x0104011301e8 (6 bytes) 09:28:45.630 SERIAL » [ACK] (0x06) 09:28:45.633 DRIVER « [RES] [SendData] was sent: true 09:28:45.639 CNTRLR [Node 007] ConfigurationCC: Loading configuration parameters from device confi g 09:28:45.651 CNTRLR [Node 007] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:28:45.652 CNTRLR [Node 007] [Configuration] 2: metadata updated 09:28:45.655 CNTRLR [Node 007] [Configuration] 3: metadata updated 09:28:45.657 CNTRLR [Node 007] [Configuration] 4: metadata updated 09:28:45.659 CNTRLR [Node 007] [Configuration] 5: metadata updated 09:28:45.661 CNTRLR [Node 007] [Configuration] 8: metadata updated 09:28:45.664 CNTRLR [Node 007] [Configuration] 9: metadata updated 09:28:45.666 CNTRLR [Node 007] [Configuration] 39: metadata updated 09:28:45.667 CNTRLR [Node 007] [Configuration] 40: metadata updated 09:28:45.669 CNTRLR [Node 007] [Configuration] 42: metadata updated 09:28:45.670 CNTRLR [Node 007] [Configuration] 43: metadata updated 09:28:45.671 CNTRLR [Node 007] [Configuration] 44: metadata updated 09:28:45.672 CNTRLR [Node 007] [Configuration] 45: metadata updated 09:28:45.674 CNTRLR [Node 007] [Configuration] 46: metadata updated 09:28:45.675 CNTRLR [Node 007] [Configuration] 81: metadata updated 09:28:45.676 CNTRLR [Node 007] [Configuration] 100: metadata updated 09:28:45.678 CNTRLR [Node 007] [Configuration] 110: metadata updated 09:28:45.679 CNTRLR [Node 007] [Configuration] 111: metadata updated 09:28:45.680 CNTRLR [Node 007] [Configuration] 112: metadata updated 09:28:45.682 CNTRLR [Node 007] [Configuration] 113: metadata updated 09:28:45.683 CNTRLR [Node 007] [Configuration] 201: metadata updated 09:28:45.684 CNTRLR [Node 007] [Configuration] 202: metadata updated 09:28:45.685 CNTRLR [Node 007] [Configuration] 203: metadata updated 09:28:45.687 CNTRLR [Node 007] [Configuration] 204: metadata updated 09:28:45.688 CNTRLR [Node 007] [Configuration] 252: metadata updated 09:28:45.689 CNTRLR [Node 007] [Configuration] 255: metadata updated 09:28:45.691 CNTRLR [Node 007] [Configuration] 101[1]: metadata updated 09:28:45.693 CNTRLR [Node 007] [Configuration] 101[16]: metadata updated 09:28:45.694 CNTRLR [Node 007] [Configuration] 101[32]: metadata updated 09:28:45.695 CNTRLR [Node 007] [Configuration] 101[64]: metadata updated 09:28:45.697 CNTRLR [Node 007] [Configuration] 101[128]: metadata updated 09:28:45.698 CNTRLR [Node 007] [Configuration] 102[1]: metadata updated 09:28:45.699 CNTRLR [Node 007] [Configuration] 102[16]: metadata updated 09:28:45.701 CNTRLR [Node 007] [Configuration] 102[32]: metadata updated 09:28:45.702 CNTRLR [Node 007] [Configuration] 102[64]: metadata updated 09:28:45.703 CNTRLR [Node 007] [Configuration] 102[128]: metadata updated 09:28:45.705 CNTRLR [Node 007] [Configuration] 103[1]: metadata updated 09:28:45.706 CNTRLR [Node 007] [Configuration] 103[16]: metadata updated 09:28:45.707 CNTRLR [Node 007] [Configuration] 103[32]: metadata updated 09:28:45.709 CNTRLR [Node 007] [Configuration] 103[64]: metadata updated 09:28:45.710 CNTRLR [Node 007] [Configuration] 103[128]: metadata updated 09:28:45.711 CNTRLR [Node 007] [Configuration] 41[15]: metadata updated 09:28:45.713 CNTRLR [Node 007] [Configuration] 41[16776960]: metadata updated 09:28:45.714 CNTRLR [Node 007] [Configuration] 201[255]: metadata updated 09:28:45.716 CNTRLR [Node 007] [Configuration] 201[65280]: metadata updated 09:28:45.717 CNTRLR [Node 007] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:28:45.717 CNTRLR » [Node 007] querying parameter #2 value... 09:28:46.914 SERIAL « 0x01070013110000877d (9 bytes) 09:28:46.915 SERIAL » [ACK] (0x06) 09:28:46.917 DRIVER « [REQ] [SendData] callback id: 17 transmit status: OK 09:28:47.004 SERIAL « 0x0110000400060a98809a81a362a8e37abaae (18 bytes) 09:28:47.005 SERIAL » [ACK] (0x06) 09:28:47.007 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x9a81a362a8e37aba 09:28:47.017 SERIAL » 0x011e001306179881a0fd333f9b72cb20ffa9a82a9aa1836e4bf6f8ebc62512f4 (32 bytes) 09:28:47.019 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 18 └─[SecurityCCCommandEncapsulation] │ nonce id: 154 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:28:47.030 SERIAL « [ACK] (0x06) 09:28:47.034 SERIAL « 0x0104011301e8 (6 bytes) 09:28:47.034 SERIAL » [ACK] (0x06) 09:28:47.036 DRIVER « [RES] [SendData] was sent: true 09:28:47.149 SERIAL « 0x010700131200000cf5 (9 bytes) 09:28:47.149 SERIAL » [ACK] (0x06) 09:28:47.150 DRIVER « [REQ] [SendData] callback id: 18 transmit status: OK 09:28:47.229 SERIAL « 0x0108000400060298402f (10 bytes) 09:28:47.230 SERIAL » [ACK] (0x06) 09:28:47.232 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:28:47.247 SERIAL » 0x01110013060a9880ae73343a59ce7dbb24004f (19 bytes) 09:28:47.248 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xae73343a59ce7dbb 09:28:47.251 SERIAL « [ACK] (0x06) 09:28:47.257 SERIAL « 0x0104011301e8 (6 bytes) 09:28:47.258 SERIAL » [ACK] (0x06) 09:28:47.259 DRIVER « [RES] [SendData] was sent: true 09:28:47.464 SERIAL « 0x0123000400061d98818cd732080c208f79e44911325787f3f84e7daec2dd052aa (37 bytes) 20e662271 09:28:47.466 SERIAL » [ACK] (0x06) 09:28:47.470 CNTRLR [Node 006] [~] [Multi Channel] commandClasses: 94,152, [Endpoint 1] [internal] 159,34 => 94,152,159,34 09:28:47.472 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 09:28:47.481 SERIAL » 0x010a001307037005022513a3 (12 bytes) 09:28:47.483 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 19 └─[ConfigurationCCGet] parameter #: 2 09:28:47.484 CNTRLR « [Node 006] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 09:28:47.484 CNTRLR » [Node 006] querying capabilities for endpoint #2... 09:28:47.491 SERIAL « [ACK] (0x06) 09:28:47.494 SERIAL « 0x0104011301e8 (6 bytes) 09:28:47.495 SERIAL » [ACK] (0x06) 09:28:47.496 DRIVER « [RES] [SendData] was sent: true 09:28:47.550 SERIAL « 0x0107001313000007ff (9 bytes) 09:28:47.551 SERIAL » [ACK] (0x06) 09:28:47.552 DRIVER « [REQ] [SendData] callback id: 19 transmit status: OK 09:28:47.564 SERIAL « 0x010b0004000705700602010087 (13 bytes) 09:28:47.578 CNTRLR [Node 007] [~] [Configuration] 2: 0 => 0 09:28:47.580 SERIAL » [ACK] (0x06) 09:28:47.582 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 0 09:28:47.589 SERIAL » 0x010a001303037005012514a3 (12 bytes) 09:28:47.590 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 20 └─[ConfigurationCCGet] parameter #: 1 09:28:47.591 CNTRLR « [Node 007] parameter #2 has value: 0 09:28:47.592 CNTRLR » [Node 007] querying parameter #3 value... 09:28:47.597 SERIAL « [ACK] (0x06) 09:28:47.600 SERIAL « 0x0104011301e8 (6 bytes) 09:28:47.601 SERIAL » [ACK] (0x06) 09:28:47.604 DRIVER « [RES] [SendData] was sent: true 09:28:47.686 SERIAL « 0x0107001314000008f7 (9 bytes) 09:28:47.687 SERIAL » [ACK] (0x06) 09:28:47.688 DRIVER « [REQ] [SendData] callback id: 20 transmit status: OK 09:28:47.750 SERIAL « 0x010b0004000305700601010181 (13 bytes) 09:28:47.759 CNTRLR [Node 003] [~] [Configuration] 1: 1 => 1 09:28:47.760 SERIAL » [ACK] (0x06) 09:28:47.761 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 1 09:28:47.768 SERIAL » 0x010a001307037005032515a4 (12 bytes) 09:28:47.769 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 21 └─[ConfigurationCCGet] parameter #: 3 09:28:47.770 CNTRLR « [Node 003] parameter #1 has value: 1 09:28:47.770 CNTRLR » [Node 003] querying parameter #16 value... 09:28:47.777 SERIAL « [ACK] (0x06) 09:28:47.783 SERIAL « 0x0104011301e8 (6 bytes) 09:28:47.783 SERIAL » [ACK] (0x06) 09:28:47.790 DRIVER « [RES] [SendData] was sent: true 09:28:47.840 SERIAL « 0x0107001315000007f9 (9 bytes) 09:28:47.841 SERIAL » [ACK] (0x06) 09:28:47.842 DRIVER « [REQ] [SendData] callback id: 21 transmit status: OK 09:28:47.855 SERIAL « 0x010c000400070670060302000a8b (14 bytes) 09:28:47.864 CNTRLR [Node 007] [~] [Configuration] 3: 10 => 10 09:28:47.865 SERIAL » [ACK] (0x06) 09:28:47.867 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 2 value: 10 09:28:47.878 SERIAL » 0x010900130602984025160a (11 bytes) 09:28:47.879 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 22 └─[SecurityCCNonceGet] 09:28:47.883 CNTRLR « [Node 007] parameter #3 has value: 10 09:28:47.884 CNTRLR » [Node 007] querying parameter #4 value... 09:28:47.889 SERIAL « [ACK] (0x06) 09:28:47.893 SERIAL « 0x0104011301e8 (6 bytes) 09:28:47.893 SERIAL » [ACK] (0x06) 09:28:47.895 DRIVER « [RES] [SendData] was sent: true 09:28:49.262 SERIAL « 0x010700131600008a77 (9 bytes) 09:28:49.262 SERIAL » [ACK] (0x06) 09:28:49.263 DRIVER « [REQ] [SendData] callback id: 22 transmit status: OK 09:28:49.350 SERIAL « 0x0110000400060a98808552eb0adfc5ade19f (18 bytes) 09:28:49.351 SERIAL » [ACK] (0x06) 09:28:49.352 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x8552eb0adfc5ade1 09:28:49.358 SERIAL » 0x011e0013061798814b4309d170cdaa961f8cfb52857cb6653720b004b425179e (32 bytes) 09:28:49.359 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 23 └─[SecurityCCCommandEncapsulation] │ nonce id: 133 └─[MultiChannelCCCapabilityGet] endpoint: 2 09:28:49.362 SERIAL « [ACK] (0x06) 09:28:49.370 SERIAL « 0x0104011301e8 (6 bytes) 09:28:49.370 SERIAL » [ACK] (0x06) 09:28:49.371 DRIVER « [RES] [SendData] was sent: true 09:28:49.499 SERIAL « 0x010700131700000df1 (9 bytes) 09:28:49.499 SERIAL » [ACK] (0x06) 09:28:49.500 DRIVER « [REQ] [SendData] callback id: 23 transmit status: OK 09:28:49.576 SERIAL « 0x0108000400060298402f (10 bytes) 09:28:49.577 SERIAL » [ACK] (0x06) 09:28:49.577 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:28:49.588 SERIAL » 0x01110013060a9880d22986fd57edf7b32400b3 (19 bytes) 09:28:49.589 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xd22986fd57edf7b3 09:28:49.591 SERIAL « [ACK] (0x06) 09:28:49.598 SERIAL « 0x0104011301e8 (6 bytes) 09:28:49.598 SERIAL » [ACK] (0x06) 09:28:49.599 DRIVER « [RES] [SendData] was sent: true 09:28:49.810 SERIAL « 0x0123000400061d9881297da5e86cdebcdee046b9f809ed1d439f06d21782319ff (37 bytes) a34c2dcee 09:28:49.812 SERIAL » [ACK] (0x06) 09:28:49.814 CNTRLR [Node 006] [~] [Multi Channel] commandClasses: 94,152, [Endpoint 2] [internal] 159,34 => 94,152,159,34 09:28:49.815 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 09:28:49.824 SERIAL » 0x010a001307037005042518ae (12 bytes) 09:28:49.825 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 24 └─[ConfigurationCCGet] parameter #: 4 09:28:49.825 CNTRLR « [Node 006] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 09:28:49.826 CNTRLR [Node 006] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:28:49.877 SERIAL « [ACK] (0x06) 09:28:49.882 SERIAL « 0x0104011301e8 (6 bytes) 09:28:49.883 SERIAL » [ACK] (0x06) 09:28:49.884 DRIVER « [RES] [SendData] was sent: true 09:28:49.888 CNTRLR [Node 006] BatteryCC: doing a partial interview... 09:28:49.888 CNTRLR » [Node 006] querying battery status... 09:28:49.900 SERIAL « 0x0107001318000008fb (9 bytes) 09:28:49.901 SERIAL » [ACK] (0x06) 09:28:49.902 DRIVER « [REQ] [SendData] callback id: 24 transmit status: OK 09:28:49.914 SERIAL « 0x010b0004000705700604010584 (13 bytes) 09:28:49.923 CNTRLR [Node 007] [~] [Configuration] 4: 5 => 5 09:28:49.925 SERIAL » [ACK] (0x06) 09:28:49.926 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 1 value: 5 09:28:49.933 SERIAL » 0x010a001303037005102519bf (12 bytes) 09:28:49.933 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 25 └─[ConfigurationCCGet] parameter #: 16 09:28:49.935 CNTRLR « [Node 007] parameter #4 has value: 5 09:28:49.935 CNTRLR » [Node 007] querying parameter #5 value... 09:28:49.941 SERIAL « [ACK] (0x06) 09:28:49.947 SERIAL « 0x0104011301e8 (6 bytes) 09:28:49.948 SERIAL » [ACK] (0x06) 09:28:49.950 DRIVER « [RES] [SendData] was sent: true 09:28:50.023 SERIAL « 0x0107001319000009fb (9 bytes) 09:28:50.024 SERIAL » [ACK] (0x06) 09:28:50.024 DRIVER « [REQ] [SendData] callback id: 25 transmit status: OK 09:28:50.162 SERIAL « 0x010b0004000305700610010190 (13 bytes) 09:28:50.168 CNTRLR [Node 003] [~] [Configuration] 16: 1 => 1 09:28:50.170 SERIAL » [ACK] (0x06) 09:28:50.171 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 1 09:28:50.203 SERIAL » 0x010a00130703700505251aad (12 bytes) 09:28:50.204 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 26 └─[ConfigurationCCGet] parameter #: 5 09:28:50.205 CNTRLR « [Node 003] parameter #16 has value: 1 09:28:50.205 CNTRLR » [Node 003] querying parameter #34 value... 09:28:50.210 SERIAL « [ACK] (0x06) 09:28:50.213 SERIAL « 0x0104011301e8 (6 bytes) 09:28:50.213 SERIAL » [ACK] (0x06) 09:28:50.214 DRIVER « [RES] [SendData] was sent: true 09:28:50.250 SERIAL « 0x010700131a000005f4 (9 bytes) 09:28:50.251 SERIAL » [ACK] (0x06) 09:28:50.253 DRIVER « [REQ] [SendData] callback id: 26 transmit status: OK 09:28:50.264 SERIAL « 0x010b0004000705700605010282 (13 bytes) 09:28:50.271 CNTRLR [Node 007] [~] [Configuration] 5: 2 => 2 09:28:50.273 SERIAL » [ACK] (0x06) 09:28:50.275 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 1 value: 2 09:28:50.297 SERIAL » 0x0109001306029840251b07 (11 bytes) 09:28:50.298 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 27 └─[SecurityCCNonceGet] 09:28:50.299 CNTRLR « [Node 007] parameter #5 has value: 2 09:28:50.299 CNTRLR » [Node 007] querying parameter #8 value... 09:28:50.304 SERIAL « [ACK] (0x06) 09:28:50.307 SERIAL « 0x0104011301e8 (6 bytes) 09:28:50.307 SERIAL » [ACK] (0x06) 09:28:50.308 DRIVER « [RES] [SendData] was sent: true 09:28:51.642 SERIAL « 0x010700131b00008676 (9 bytes) 09:28:51.643 SERIAL » [ACK] (0x06) 09:28:51.647 DRIVER « [REQ] [SendData] callback id: 27 transmit status: OK 09:28:51.728 SERIAL « 0x0110000400060a9880d07298c5db93477778 (18 bytes) 09:28:51.729 SERIAL » [ACK] (0x06) 09:28:51.733 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xd07298c5db934777 09:28:51.742 SERIAL » 0x011d00130616988118b6aff7ebbeb936be8266d0e16d5b2fb845c25f251cff (31 bytes) 09:28:51.743 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 28 └─[SecurityCCCommandEncapsulation] │ nonce id: 208 └─[BatteryCCGet] 09:28:51.747 SERIAL « [ACK] (0x06) 09:28:51.754 SERIAL « 0x0104011301e8 (6 bytes) 09:28:51.755 SERIAL » [ACK] (0x06) 09:28:51.756 DRIVER « [RES] [SendData] was sent: true 09:28:51.867 SERIAL « 0x010700131c00000cfb (9 bytes) 09:28:51.867 SERIAL » [ACK] (0x06) 09:28:51.869 DRIVER « [REQ] [SendData] callback id: 28 transmit status: OK 09:28:51.967 SERIAL « 0x0108000400060298402f (10 bytes) 09:28:51.968 SERIAL » [ACK] (0x06) 09:28:51.970 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:28:51.985 SERIAL » 0x01110013060a9880e3cd26663c37dc2a24005e (19 bytes) 09:28:51.986 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xe3cd26663c37dc2a 09:28:51.989 SERIAL « [ACK] (0x06) 09:28:51.995 SERIAL « 0x0104011301e8 (6 bytes) 09:28:51.996 SERIAL » [ACK] (0x06) 09:28:51.997 DRIVER « [RES] [SendData] was sent: true 09:28:52.194 SERIAL « 0x011d00040006179881df17a46e19c41a4de5e878e3e3944f3169dc900931e4 (31 bytes) 09:28:52.196 SERIAL » [ACK] (0x06) 09:28:52.200 CNTRLR [Node 006] [~] [Battery] level: 90 => 89 [Endpoint 0] 09:28:52.201 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 0] 09:28:52.203 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[BatteryCCReport] level: 89 is low: false 09:28:52.214 SERIAL » 0x010a00130703700508251da7 (12 bytes) 09:28:52.215 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 29 └─[ConfigurationCCGet] parameter #: 8 09:28:52.218 CNTRLR « [Node 006] received response for battery information: level: 89 09:28:52.220 CNTRLR [Node 006] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:28:52.307 SERIAL « [ACK] (0x06) 09:28:52.309 SERIAL « 0x0104011301e8 (6 bytes) 09:28:52.309 SERIAL » [ACK] (0x06) 09:28:52.314 DRIVER « [RES] [SendData] was sent: true 09:28:52.317 SERIAL « 0x010700131d000007f1 (9 bytes) 09:28:52.318 SERIAL » [ACK] (0x06) 09:28:52.322 CNTRLR [Node 006] ZWavePlusCC: doing a partial interview... [Endpoint 1] 09:28:52.322 CNTRLR [Node 006] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 09:28:52.324 CNTRLR [Node 006] ThermostatModeCC: doing a partial interview... [Endpoint 1] 09:28:52.324 CNTRLR » [Node 006] querying current thermostat mode... [Endpoint 1] 09:28:52.333 DRIVER « [REQ] [SendData] callback id: 29 transmit status: OK 09:28:52.336 SERIAL « 0x010b0004000705700608010f82 (13 bytes) 09:28:52.343 CNTRLR [Node 007] [~] [Configuration] 8: 15 => 15 09:28:52.346 SERIAL » [ACK] (0x06) 09:28:52.347 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 15 09:28:52.352 SERIAL » 0x010a00130303700522251e8a (12 bytes) 09:28:52.352 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 30 └─[ConfigurationCCGet] parameter #: 34 09:28:52.353 CNTRLR « [Node 007] parameter #8 has value: 15 09:28:52.353 CNTRLR » [Node 007] querying parameter #9 value... 09:28:52.358 SERIAL « [ACK] (0x06) 09:28:52.361 SERIAL « 0x0104011301e8 (6 bytes) 09:28:52.362 SERIAL » [ACK] (0x06) 09:28:52.363 DRIVER « [RES] [SendData] was sent: true 09:28:52.440 SERIAL « 0x010700131e000009fc (9 bytes) 09:28:52.441 SERIAL » [ACK] (0x06) 09:28:52.441 DRIVER « [REQ] [SendData] callback id: 30 transmit status: OK 09:28:52.512 SERIAL « 0x010b0004000305700622013f9c (13 bytes) 09:28:52.517 CNTRLR [Node 003] [~] [Configuration] 34: 63 => 63 09:28:52.518 SERIAL » [ACK] (0x06) 09:28:52.520 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 34 value size: 1 value: 63 09:28:52.524 SERIAL » 0x010a00130703700509251fa4 (12 bytes) 09:28:52.525 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 31 └─[ConfigurationCCGet] parameter #: 9 09:28:52.525 CNTRLR « [Node 003] parameter #34 has value: 63 09:28:52.526 CNTRLR » [Node 003] querying parameter #35 value... 09:28:52.540 SERIAL « [ACK] (0x06) 09:28:52.543 SERIAL « 0x0104011301e8 (6 bytes) 09:28:52.543 SERIAL » [ACK] (0x06) 09:28:52.544 DRIVER « [RES] [SendData] was sent: true 09:28:52.610 SERIAL « 0x010700131f000009fd (9 bytes) 09:28:52.611 SERIAL » [ACK] (0x06) 09:28:52.612 DRIVER « [REQ] [SendData] callback id: 31 transmit status: OK 09:28:52.624 SERIAL « 0x010c00040007067006090200008b (14 bytes) 09:28:52.629 CNTRLR [Node 007] [~] [Configuration] 9: 0 => 0 09:28:52.631 SERIAL » [ACK] (0x06) 09:28:52.632 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 2 value: 0 09:28:52.638 SERIAL » 0x010900130602984025203c (11 bytes) 09:28:52.639 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 32 └─[SecurityCCNonceGet] 09:28:52.640 CNTRLR « [Node 007] parameter #9 has value: 0 09:28:52.640 CNTRLR » [Node 007] querying parameter #39 value... 09:28:52.644 SERIAL « [ACK] (0x06) 09:28:52.647 SERIAL « 0x0104011301e8 (6 bytes) 09:28:52.648 SERIAL » [ACK] (0x06) 09:28:52.649 DRIVER « [RES] [SendData] was sent: true 09:28:52.705 SERIAL « 0x0107001320000006cd (9 bytes) 09:28:52.706 SERIAL » [ACK] (0x06) 09:28:52.706 DRIVER « [REQ] [SendData] callback id: 32 transmit status: OK 09:28:52.788 SERIAL « 0x0110000400060a988064f87b1243f1e77728 (18 bytes) 09:28:52.789 SERIAL » [ACK] (0x06) 09:28:52.789 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x64f87b1243f1e777 09:28:52.795 SERIAL » 0x01210013061a98816e1def1551e2f882c8afea842e1b9864d21237e981ea5e1b2 (35 bytes) 5217c 09:28:52.795 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 33 └─[SecurityCCCommandEncapsulation] │ nonce id: 100 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:28:52.799 SERIAL « [ACK] (0x06) 09:28:52.806 SERIAL « 0x0104011301e8 (6 bytes) 09:28:52.806 SERIAL » [ACK] (0x06) 09:28:52.807 DRIVER « [RES] [SendData] was sent: true 09:28:52.928 SERIAL « 0x010700132100000cc6 (9 bytes) 09:28:52.928 SERIAL » [ACK] (0x06) 09:28:52.929 DRIVER « [REQ] [SendData] callback id: 33 transmit status: OK 09:28:53.014 SERIAL « 0x0108000400060298402f (10 bytes) 09:28:53.015 SERIAL » [ACK] (0x06) 09:28:53.016 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:28:53.027 SERIAL » 0x01110013060a9880a5cdb3e7d9bde558240028 (19 bytes) 09:28:53.028 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xa5cdb3e7d9bde558 09:28:53.031 SERIAL « [ACK] (0x06) 09:28:53.038 SERIAL « 0x0104011301e8 (6 bytes) 09:28:53.039 SERIAL » [ACK] (0x06) 09:28:53.040 DRIVER « [RES] [SendData] was sent: true 09:28:53.247 SERIAL « 0x0121000400061b98819416c61c8da4f6d0de69d5c5e93ac06da561835384d6133 (35 bytes) 5d5e5 09:28:53.249 SERIAL » [ACK] (0x06) 09:28:53.254 CNTRLR [Node 006] [~] [Thermostat Mode] mode: 0 => 0 [Endpoint 1] 09:28:53.257 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Off 09:28:53.271 SERIAL » 0x010a001307037005272522b7 (12 bytes) 09:28:53.272 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 34 └─[ConfigurationCCGet] parameter #: 39 09:28:53.274 CNTRLR « [Node 006] received current thermostat mode: Off [Endpoint 1] 09:28:53.276 CNTRLR [Node 006] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 1] [internal] ue => true 09:28:53.336 SERIAL « [ACK] (0x06) 09:28:53.340 SERIAL « 0x0104011301e8 (6 bytes) 09:28:53.341 SERIAL » [ACK] (0x06) 09:28:53.342 DRIVER « [RES] [SendData] was sent: true 09:28:53.347 CNTRLR [Node 006] ThermostatSetpointCC: doing a partial interview... [Endpoint 1] 09:28:53.347 CNTRLR » [Node 006] querying current value of setpoint Heating... [Endpoint 1] 09:28:53.362 SERIAL « 0x0107001322000007ce (9 bytes) 09:28:53.363 SERIAL » [ACK] (0x06) 09:28:53.364 DRIVER « [REQ] [SendData] callback id: 34 transmit status: OK 09:28:53.367 SERIAL « 0x010b00040007057006270114b6 (13 bytes) 09:28:53.372 CNTRLR [Node 007] [~] [Configuration] 39: 20 => 20 09:28:53.373 SERIAL » [ACK] (0x06) 09:28:53.374 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 39 value size: 1 value: 20 09:28:53.379 SERIAL » 0x010a001303037005232523b6 (12 bytes) 09:28:53.379 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 35 └─[ConfigurationCCGet] parameter #: 35 09:28:53.380 CNTRLR « [Node 007] parameter #39 has value: 20 09:28:53.380 CNTRLR » [Node 007] querying parameter #40 value... 09:28:53.385 SERIAL « [ACK] (0x06) 09:28:53.389 SERIAL « 0x0104011301e8 (6 bytes) 09:28:53.389 SERIAL » [ACK] (0x06) 09:28:53.391 DRIVER « [RES] [SendData] was sent: true 09:28:53.468 SERIAL « 0x0107001323000008c0 (9 bytes) 09:28:53.468 SERIAL » [ACK] (0x06) 09:28:53.469 DRIVER « [REQ] [SendData] callback id: 35 transmit status: OK 09:28:53.540 SERIAL « 0x010b00040003057006230100a2 (13 bytes) 09:28:53.545 CNTRLR [Node 003] [~] [Configuration] 35: 0 => 0 09:28:53.546 SERIAL » [ACK] (0x06) 09:28:53.548 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 0 09:28:53.554 SERIAL » 0x010a001307037005282524be (12 bytes) 09:28:53.554 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 36 └─[ConfigurationCCGet] parameter #: 40 09:28:53.555 CNTRLR « [Node 003] parameter #35 has value: 0 09:28:53.555 CNTRLR » [Node 003] querying parameter #39 value... 09:28:53.559 SERIAL « [ACK] (0x06) 09:28:53.564 SERIAL « 0x0104011301e8 (6 bytes) 09:28:53.565 SERIAL » [ACK] (0x06) 09:28:53.566 DRIVER « [RES] [SendData] was sent: true 09:28:53.640 SERIAL « 0x0107001324000009c6 (9 bytes) 09:28:53.640 SERIAL » [ACK] (0x06) 09:28:53.641 DRIVER « [REQ] [SendData] callback id: 36 transmit status: OK 09:28:53.654 SERIAL « 0x010b00040007057006280100ad (13 bytes) 09:28:53.659 CNTRLR [Node 007] [~] [Configuration] 40: 0 => 0 09:28:53.660 SERIAL » [ACK] (0x06) 09:28:53.661 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 0 09:28:53.667 SERIAL » 0x0109001306029840252539 (11 bytes) 09:28:53.668 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 37 └─[SecurityCCNonceGet] 09:28:53.669 CNTRLR « [Node 007] parameter #40 has value: 0 09:28:53.669 CNTRLR » [Node 007] querying parameter #42 value... 09:28:53.674 SERIAL « [ACK] (0x06) 09:28:53.677 SERIAL « 0x0104011301e8 (6 bytes) 09:28:53.678 SERIAL » [ACK] (0x06) 09:28:53.680 DRIVER « [RES] [SendData] was sent: true 09:28:53.735 SERIAL « 0x0107001325000006c8 (9 bytes) 09:28:53.735 SERIAL » [ACK] (0x06) 09:28:53.736 DRIVER « [REQ] [SendData] callback id: 37 transmit status: OK 09:28:53.761 SERIAL « 0x01090004001b033003ff26 (11 bytes) 09:28:53.762 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:28:53.763 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:28:53.764 SERIAL » [ACK] (0x06) 09:28:53.770 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:28:53.787 SERIAL « 0x01090004001b032001ff34 (11 bytes) 09:28:53.790 SERIAL » [ACK] (0x06) 09:28:53.792 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:28:53.807 CNTRLR [Node 027] treating BasicCC Set as a report 09:28:53.808 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:28:53.820 SERIAL « 0x0110000400060a9880ea8070e1562b874cb2 (18 bytes) 09:28:53.821 SERIAL » [ACK] (0x06) 09:28:53.822 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xea8070e1562b874c 09:28:53.830 SERIAL » 0x01220013061b9881d0b3c558a65aab76128fcb3e5ea2fcbfea6e77c1dc2c0d825 (36 bytes) b2526d7 09:28:53.831 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 38 └─[SecurityCCCommandEncapsulation] │ nonce id: 234 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:28:53.835 SERIAL « [ACK] (0x06) 09:28:53.843 SERIAL « 0x0104011301e8 (6 bytes) 09:28:53.843 SERIAL » [ACK] (0x06) 09:28:53.844 DRIVER « [RES] [SendData] was sent: true 09:28:53.970 SERIAL « 0x010700132600000dc0 (9 bytes) 09:28:53.970 SERIAL » [ACK] (0x06) 09:28:53.971 DRIVER « [REQ] [SendData] callback id: 38 transmit status: OK 09:28:54.054 SERIAL « 0x0108000400060298402f (10 bytes) 09:28:54.055 SERIAL » [ACK] (0x06) 09:28:54.056 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:28:54.067 SERIAL » 0x01110013060a9880cc0d928c3ad88f0a240075 (19 bytes) 09:28:54.068 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xcc0d928c3ad88f0a 09:28:54.071 SERIAL « [ACK] (0x06) 09:28:54.079 SERIAL « 0x0104011301e8 (6 bytes) 09:28:54.079 SERIAL » [ACK] (0x06) 09:28:54.080 DRIVER « [RES] [SendData] was sent: true 09:28:54.288 SERIAL « 0x0124000400061e98816f0a9be9b3ada1bc43cd9c568c86616b803a29ccc0516ef (38 bytes) 2e7188cdf70 09:28:54.290 SERIAL » [ACK] (0x06) 09:28:54.295 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 1] 09:28:54.296 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 09:28:54.298 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 09:28:54.307 SERIAL » 0x010a0013070370052a2527bf (12 bytes) 09:28:54.307 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[ConfigurationCCGet] parameter #: 42 09:28:54.313 CNTRLR « [Node 006] received current value of setpoint Heating: 10 °C [Endpoint 1] 09:28:54.315 CNTRLR [Node 006] [~] [Thermostat Setpoint] interviewComplete [Endpoint 1] [internal] : true => true 09:28:54.375 SERIAL « [ACK] (0x06) 09:28:54.377 SERIAL « 0x0104011301e8 (6 bytes) 09:28:54.377 SERIAL » [ACK] (0x06) 09:28:54.381 DRIVER « [RES] [SendData] was sent: true 09:28:54.383 SERIAL « 0x0107001327000007cb (9 bytes) 09:28:54.384 SERIAL » [ACK] (0x06) 09:28:54.386 CNTRLR [Node 006] NotificationCC: doing a partial interview... [Endpoint 1] 09:28:54.387 CNTRLR » [Node 006] querying notification status for Power Management... [Endpoint 1] 09:28:54.405 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 09:28:54.409 SERIAL « 0x010b000400070570062a010aa5 (13 bytes) 09:28:54.415 CNTRLR [Node 007] [~] [Configuration] 42: 10 => 10 09:28:54.416 SERIAL » [ACK] (0x06) 09:28:54.418 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 10 09:28:54.424 SERIAL » 0x010a001303037005272528b9 (12 bytes) 09:28:54.425 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 40 └─[ConfigurationCCGet] parameter #: 39 09:28:54.426 CNTRLR « [Node 007] parameter #42 has value: 10 09:28:54.426 CNTRLR » [Node 007] querying parameter #43 value... 09:28:54.440 SERIAL « [ACK] (0x06) 09:28:54.441 SERIAL « 0x0104011301e8 (6 bytes) 09:28:54.442 SERIAL » [ACK] (0x06) 09:28:54.443 DRIVER « [RES] [SendData] was sent: true 09:28:54.514 SERIAL « 0x0107001328000009ca (9 bytes) 09:28:54.515 SERIAL » [ACK] (0x06) 09:28:54.516 DRIVER « [REQ] [SendData] callback id: 40 transmit status: OK 09:28:54.570 SERIAL « 0x010c0004000306700627020258fb (14 bytes) 09:28:54.575 CNTRLR [Node 003] [~] [Configuration] 39: 600 => 600 09:28:54.577 SERIAL » [ACK] (0x06) 09:28:54.580 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 39 value size: 2 value: 600 09:28:54.585 SERIAL » 0x010a0013070370052b2529b0 (12 bytes) 09:28:54.586 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 41 └─[ConfigurationCCGet] parameter #: 43 09:28:54.586 CNTRLR « [Node 003] parameter #39 has value: 600 09:28:54.586 CNTRLR » [Node 003] querying parameter #40 value... 09:28:54.597 SERIAL « [ACK] (0x06) 09:28:54.599 SERIAL « 0x0104011301e8 (6 bytes) 09:28:54.599 SERIAL » [ACK] (0x06) 09:28:54.601 DRIVER « [RES] [SendData] was sent: true 09:28:54.660 SERIAL « 0x0107001329000007c5 (9 bytes) 09:28:54.660 SERIAL » [ACK] (0x06) 09:28:54.662 DRIVER « [REQ] [SendData] callback id: 41 transmit status: OK 09:28:54.675 SERIAL « 0x010c000400070670062b020064cd (14 bytes) 09:28:54.680 CNTRLR [Node 007] [~] [Configuration] 43: 100 => 100 09:28:54.681 SERIAL » [ACK] (0x06) 09:28:54.685 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 2 value: 100 09:28:54.691 SERIAL » 0x0109001306029840252a36 (11 bytes) 09:28:54.691 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 42 └─[SecurityCCNonceGet] 09:28:54.692 CNTRLR « [Node 007] parameter #43 has value: 100 09:28:54.692 CNTRLR » [Node 007] querying parameter #44 value... 09:28:54.704 SERIAL « [ACK] (0x06) 09:28:54.707 SERIAL « 0x0104011301e8 (6 bytes) 09:28:54.707 SERIAL » [ACK] (0x06) 09:28:54.708 DRIVER « [RES] [SendData] was sent: true 09:28:54.758 SERIAL « 0x010700132a000006c7 (9 bytes) 09:28:54.758 SERIAL » [ACK] (0x06) 09:28:54.759 DRIVER « [REQ] [SendData] callback id: 42 transmit status: OK 09:28:54.848 SERIAL « 0x0110000400060a988069c0a03883a3ec989a (18 bytes) 09:28:54.848 SERIAL » [ACK] (0x06) 09:28:54.849 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x69c0a03883a3ec98 09:28:54.854 SERIAL » 0x01240013061d98816d50841e37a0851a1e958217c850ec1a984869d6f784eda92 (38 bytes) 05d4f252b71 09:28:54.855 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 43 └─[SecurityCCCommandEncapsulation] │ nonce id: 105 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: Power Management 09:28:54.858 SERIAL « [ACK] (0x06) 09:28:54.865 SERIAL « 0x0104011301e8 (6 bytes) 09:28:54.866 SERIAL » [ACK] (0x06) 09:28:54.866 DRIVER « [RES] [SendData] was sent: true 09:28:54.991 SERIAL « 0x010700132b00000ece (9 bytes) 09:28:54.992 SERIAL » [ACK] (0x06) 09:28:54.992 DRIVER « [REQ] [SendData] callback id: 43 transmit status: OK 09:28:55.074 SERIAL « 0x0108000400060298402f (10 bytes) 09:28:55.074 SERIAL » [ACK] (0x06) 09:28:55.075 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:28:55.081 SERIAL » 0x01110013060a98808650ab882e8c0596240009 (19 bytes) 09:28:55.081 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x8650ab882e8c0596 09:28:55.084 SERIAL « [ACK] (0x06) 09:28:55.090 SERIAL « 0x0104011301e8 (6 bytes) 09:28:55.091 SERIAL » [ACK] (0x06) 09:28:55.092 DRIVER « [RES] [SendData] was sent: true 09:28:55.309 SERIAL « 0x012700040006219881680fc649d8eec931d36108397eedb02a94ee67b6037f869 (41 bytes) f85c060687095153d 09:28:55.311 SERIAL » [ACK] (0x06) 09:28:55.316 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 09:28:55.324 SERIAL » 0x010a0013070370052c252cb2 (12 bytes) 09:28:55.324 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 44 └─[ConfigurationCCGet] parameter #: 44 09:28:55.327 CNTRLR [Node 006] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 1] 54 09:28:55.329 CNTRLR » [Node 006] querying notification status for System... [Endpoint 1] 09:28:55.336 SERIAL « [ACK] (0x06) 09:28:55.339 SERIAL « 0x0104011301e8 (6 bytes) 09:28:55.339 SERIAL » [ACK] (0x06) 09:28:55.340 DRIVER « [RES] [SendData] was sent: true 09:28:55.400 SERIAL « 0x010700132c000008cf (9 bytes) 09:28:55.401 SERIAL » [ACK] (0x06) 09:28:55.403 DRIVER « [REQ] [SendData] callback id: 44 transmit status: OK 09:28:55.414 SERIAL « 0x010b000400070570062c010aa3 (13 bytes) 09:28:55.422 CNTRLR [Node 007] [~] [Configuration] 44: 10 => 10 09:28:55.423 SERIAL » [ACK] (0x06) 09:28:55.425 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 44 value size: 1 value: 10 09:28:55.430 SERIAL » 0x010a00130303700528252db3 (12 bytes) 09:28:55.431 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 45 └─[ConfigurationCCGet] parameter #: 40 09:28:55.432 CNTRLR « [Node 007] parameter #44 has value: 10 09:28:55.433 CNTRLR » [Node 007] querying parameter #45 value... 09:28:55.442 SERIAL « [ACK] (0x06) 09:28:55.445 SERIAL « 0x0104011301e8 (6 bytes) 09:28:55.448 SERIAL » [ACK] (0x06) 09:28:55.450 DRIVER « [RES] [SendData] was sent: true 09:28:55.520 SERIAL « 0x010700132d000008ce (9 bytes) 09:28:55.520 SERIAL » [ACK] (0x06) 09:28:55.521 DRIVER « [REQ] [SendData] callback id: 45 transmit status: OK 09:28:55.590 SERIAL « 0x010b00040003057006280150f9 (13 bytes) 09:28:55.598 CNTRLR [Node 003] [~] [Configuration] 40: 80 => 80 09:28:55.600 SERIAL » [ACK] (0x06) 09:28:55.601 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 80 09:28:55.624 SERIAL » 0x010a0013070370052d252eb1 (12 bytes) 09:28:55.625 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 46 └─[ConfigurationCCGet] parameter #: 45 09:28:55.642 CNTRLR « [Node 003] parameter #40 has value: 80 09:28:55.643 CNTRLR » [Node 003] querying parameter #42 value... 09:28:55.651 SERIAL « [ACK] (0x06) 09:28:55.655 SERIAL « 0x0104011301e8 (6 bytes) 09:28:55.655 SERIAL » [ACK] (0x06) 09:28:55.657 DRIVER « [RES] [SendData] was sent: true 09:28:55.680 SERIAL « 0x010700132e000004c1 (9 bytes) 09:28:55.681 SERIAL » [ACK] (0x06) 09:28:55.682 DRIVER « [REQ] [SendData] callback id: 46 transmit status: OK 09:28:55.694 SERIAL « 0x010b000400070570062d0102aa (13 bytes) 09:28:55.702 CNTRLR [Node 007] [~] [Configuration] 45: 2 => 2 09:28:55.704 SERIAL » [ACK] (0x06) 09:28:55.705 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 45 value size: 1 value: 2 09:28:55.714 SERIAL » 0x0109001306029840252f33 (11 bytes) 09:28:55.715 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 47 └─[SecurityCCNonceGet] 09:28:55.717 CNTRLR « [Node 007] parameter #45 has value: 2 09:28:55.717 CNTRLR » [Node 007] querying parameter #46 value... 09:28:55.723 SERIAL « [ACK] (0x06) 09:28:55.725 SERIAL « 0x0104011301e8 (6 bytes) 09:28:55.725 SERIAL » [ACK] (0x06) 09:28:55.726 DRIVER « [RES] [SendData] was sent: true 09:28:55.782 SERIAL « 0x010700132f000007c3 (9 bytes) 09:28:55.783 SERIAL » [ACK] (0x06) 09:28:55.783 DRIVER « [REQ] [SendData] callback id: 47 transmit status: OK 09:28:55.868 SERIAL « 0x0110000400060a9880deaad8da62d5863981 (18 bytes) 09:28:55.869 SERIAL » [ACK] (0x06) 09:28:55.870 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xdeaad8da62d58639 09:28:55.875 SERIAL » 0x01240013061d988178c0a8302670dae17ba32cc68ef2e7eb2284de1f7c0707d4a (38 bytes) de8c9253093 09:28:55.876 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 48 └─[SecurityCCCommandEncapsulation] │ nonce id: 222 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: System 09:28:55.880 SERIAL « [ACK] (0x06) 09:28:55.887 SERIAL « 0x0104011301e8 (6 bytes) 09:28:55.887 SERIAL » [ACK] (0x06) 09:28:55.888 DRIVER « [RES] [SendData] was sent: true 09:28:56.012 SERIAL « 0x010700133000000dd6 (9 bytes) 09:28:56.012 SERIAL » [ACK] (0x06) 09:28:56.013 DRIVER « [REQ] [SendData] callback id: 48 transmit status: OK 09:28:56.094 SERIAL « 0x0108000400060298402f (10 bytes) 09:28:56.094 SERIAL » [ACK] (0x06) 09:28:56.096 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:28:56.102 SERIAL » 0x01110013060a988059330d5d7d835ce52400b0 (19 bytes) 09:28:56.103 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x59330d5d7d835ce5 09:28:56.105 SERIAL « [ACK] (0x06) 09:28:56.112 SERIAL « 0x0104011301e8 (6 bytes) 09:28:56.113 SERIAL » [ACK] (0x06) 09:28:56.114 DRIVER « [RES] [SendData] was sent: true 09:28:56.330 SERIAL « 0x01270004000621988113448fb664dde941cfc2df50ff222923db302794377b59d (41 bytes) 1ef7245d87246c3a3 09:28:56.331 SERIAL » [ACK] (0x06) 09:28:56.332 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: System notification status: 255 notification event: Unknown (0xfe) 09:28:56.336 SERIAL » 0x010a0013070370052e2531ad (12 bytes) 09:28:56.337 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 49 └─[ConfigurationCCGet] parameter #: 46 09:28:56.338 CNTRLR [Node 006] [~] [Notification] System[unknown]: 254 => 254 [Endpoint 1] 09:28:56.339 CNTRLR [Node 006] [~] [Notification] interviewComplete: true [Endpoint 1] [internal] => true 09:28:56.366 SERIAL « [ACK] (0x06) 09:28:56.371 SERIAL « 0x0104011301e8 (6 bytes) 09:28:56.371 SERIAL » [ACK] (0x06) 09:28:56.374 DRIVER « [RES] [SendData] was sent: true 09:28:56.377 CNTRLR [Node 006] ProtectionCC: doing a partial interview... 09:28:56.378 CNTRLR » [Node 006] querying protection status... 09:28:56.420 SERIAL « 0x0107001331000009d3 (9 bytes) 09:28:56.420 SERIAL » [ACK] (0x06) 09:28:56.421 DRIVER « [REQ] [SendData] callback id: 49 transmit status: OK 09:28:56.434 SERIAL « 0x010b000400070570062e0100ab (13 bytes) 09:28:56.439 CNTRLR [Node 007] [~] [Configuration] 46: 0 => 0 09:28:56.441 SERIAL » [ACK] (0x06) 09:28:56.441 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 46 value size: 1 value: 0 09:28:56.445 SERIAL » 0x010a0013030370052a2532ae (12 bytes) 09:28:56.446 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 50 └─[ConfigurationCCGet] parameter #: 42 09:28:56.447 CNTRLR « [Node 007] parameter #46 has value: 0 09:28:56.447 CNTRLR » [Node 007] querying parameter #81 value... 09:28:56.452 SERIAL « [ACK] (0x06) 09:28:56.457 SERIAL « 0x0104011301e8 (6 bytes) 09:28:56.458 SERIAL » [ACK] (0x06) 09:28:56.459 DRIVER « [RES] [SendData] was sent: true 09:28:56.535 SERIAL « 0x0107001332000009d0 (9 bytes) 09:28:56.535 SERIAL » [ACK] (0x06) 09:28:56.536 DRIVER « [REQ] [SendData] callback id: 50 transmit status: OK 09:28:56.606 SERIAL « 0x010b000400030570062a010fa4 (13 bytes) 09:28:56.611 CNTRLR [Node 003] [~] [Configuration] 42: 15 => 15 09:28:56.612 SERIAL » [ACK] (0x06) 09:28:56.613 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 15 09:28:56.617 SERIAL » 0x010a001307037005512533d0 (12 bytes) 09:28:56.618 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 51 └─[ConfigurationCCGet] parameter #: 81 09:28:56.618 CNTRLR « [Node 003] parameter #42 has value: 15 09:28:56.618 CNTRLR » [Node 003] querying parameter #43 value... 09:28:56.622 SERIAL « [ACK] (0x06) 09:28:56.627 SERIAL « 0x0104011301e8 (6 bytes) 09:28:56.628 SERIAL » [ACK] (0x06) 09:28:56.629 DRIVER « [RES] [SendData] was sent: true 09:28:56.700 SERIAL « 0x0107001333000008d0 (9 bytes) 09:28:56.700 SERIAL » [ACK] (0x06) 09:28:56.701 DRIVER « [REQ] [SendData] callback id: 51 transmit status: OK 09:28:56.715 SERIAL « 0x010b00040007057006510100d4 (13 bytes) 09:28:56.720 CNTRLR [Node 007] [~] [Configuration] 81: 0 => 0 09:28:56.721 SERIAL » [ACK] (0x06) 09:28:56.722 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 81 value size: 1 value: 0 09:28:56.731 SERIAL » 0x0109001306029840253428 (11 bytes) 09:28:56.731 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 52 └─[SecurityCCNonceGet] 09:28:56.732 CNTRLR « [Node 007] parameter #81 has value: 0 09:28:56.733 CNTRLR » [Node 007] querying parameter #111 value... 09:28:56.737 SERIAL « [ACK] (0x06) 09:28:56.741 SERIAL « 0x0104011301e8 (6 bytes) 09:28:56.741 SERIAL » [ACK] (0x06) 09:28:56.743 DRIVER « [RES] [SendData] was sent: true 09:28:56.804 SERIAL « 0x0107001334000007d8 (9 bytes) 09:28:56.804 SERIAL » [ACK] (0x06) 09:28:56.805 DRIVER « [REQ] [SendData] callback id: 52 transmit status: OK 09:28:56.888 SERIAL « 0x0110000400060a9880eedd804e3cf274eb53 (18 bytes) 09:28:56.888 SERIAL » [ACK] (0x06) 09:28:56.889 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xeedd804e3cf274eb 09:28:56.893 SERIAL » 0x01210013061a98817a57a7a14364ab30f546fde2a40865ee7b9cdb9461da51962 (35 bytes) 53510 09:28:56.894 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 53 └─[SecurityCCCommandEncapsulation] │ nonce id: 238 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 09:28:56.897 SERIAL « [ACK] (0x06) 09:28:56.904 SERIAL « 0x0104011301e8 (6 bytes) 09:28:56.905 SERIAL » [ACK] (0x06) 09:28:56.905 DRIVER « [RES] [SendData] was sent: true 09:28:57.028 SERIAL « 0x010700133500000dd3 (9 bytes) 09:28:57.028 SERIAL » [ACK] (0x06) 09:28:57.029 DRIVER « [REQ] [SendData] callback id: 53 transmit status: OK 09:28:57.113 SERIAL « 0x0108000400060298402f (10 bytes) 09:28:57.114 SERIAL » [ACK] (0x06) 09:28:57.114 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:28:57.120 SERIAL » 0x01110013060a9880cea93186eb2f0e5c24008b (19 bytes) 09:28:57.120 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xcea93186eb2f0e5c 09:28:57.122 SERIAL « [ACK] (0x06) 09:28:57.129 SERIAL « 0x0104011301e8 (6 bytes) 09:28:57.129 SERIAL » [ACK] (0x06) 09:28:57.130 DRIVER « [RES] [SendData] was sent: true 09:28:57.347 SERIAL « 0x0121000400061b9881b564f579aaabbb619c5f1e23302546c3ce385fb542102a6 (35 bytes) 23c0c 09:28:57.348 SERIAL » [ACK] (0x06) 09:28:57.352 CNTRLR [Node 006] [~] [Protection] local: 0 => 0 [Endpoint 1] 09:28:57.355 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ProtectionCCReport] local: Unprotected 09:28:57.378 SERIAL » 0x010a0013070370056f2536eb (12 bytes) 09:28:57.379 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 54 └─[ConfigurationCCGet] parameter #: 111 09:28:57.380 CNTRLR « [Node 006] received protection status: local: Unprotected 09:28:57.382 CNTRLR [Node 006] [~] [Protection] interviewComplete: true => [Endpoint 1] [internal] true 09:28:57.435 SERIAL « [ACK] (0x06) 09:28:57.440 SERIAL « 0x0104011301e8 (6 bytes) 09:28:57.441 SERIAL » [ACK] (0x06) 09:28:57.442 DRIVER « [RES] [SendData] was sent: true 09:28:57.446 SERIAL « 0x0107001336000006db (9 bytes) 09:28:57.447 SERIAL » [ACK] (0x06) 09:28:57.448 DRIVER « [REQ] [SendData] callback id: 54 transmit status: OK 09:28:57.455 SERIAL « 0x010e000400070870066f0400000e10f9 (16 bytes) 09:28:57.466 CNTRLR [Node 007] [~] [Configuration] 111: 3600 => 3600 09:28:57.467 SERIAL » [ACK] (0x06) 09:28:57.469 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 111 value size: 4 value: 3600 09:28:57.473 SERIAL » 0x010a0013030370052b2537aa (12 bytes) 09:28:57.474 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 55 └─[ConfigurationCCGet] parameter #: 43 09:28:57.475 CNTRLR « [Node 007] parameter #111 has value: 3600 09:28:57.475 CNTRLR » [Node 007] querying parameter #112 value... 09:28:57.481 SERIAL « [ACK] (0x06) 09:28:57.488 SERIAL « 0x0104011301e8 (6 bytes) 09:28:57.489 SERIAL » [ACK] (0x06) 09:28:57.490 DRIVER « [RES] [SendData] was sent: true 09:28:57.563 SERIAL « 0x0107001337000009d5 (9 bytes) 09:28:57.563 SERIAL » [ACK] (0x06) 09:28:57.564 DRIVER « [REQ] [SendData] callback id: 55 transmit status: OK 09:28:57.634 SERIAL « 0x010b000400030570062b011eb4 (13 bytes) 09:28:57.639 CNTRLR [Node 003] [~] [Configuration] 43: 30 => 30 09:28:57.640 SERIAL » [ACK] (0x06) 09:28:57.643 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 30 09:28:57.648 SERIAL » 0x010800130801002538f0 (10 bytes) 09:28:57.648 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 56 └─[NoOperationCC] 09:28:57.648 CNTRLR « [Node 003] parameter #43 has value: 30 09:28:57.649 CNTRLR » [Node 003] querying parameter #45 value... 09:28:57.665 CNTRLR [Node 006] BatteryCC: doing a partial interview... [Endpoint 1] 09:28:57.665 CNTRLR » [Node 006] querying battery status... [Endpoint 1] 09:28:57.669 SERIAL « [ACK] (0x06) 09:28:57.672 SERIAL « 0x0104011301e8 (6 bytes) 09:28:57.682 SERIAL » [ACK] (0x06) 09:28:57.684 DRIVER « [RES] [SendData] was sent: true 09:29:10.283 SERIAL « 0x010c00040003063105042208ff17 (14 bytes) 09:29:10.285 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:29:10.287 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 120.4 => 230.3 [Endpoint 0] 09:29:10.288 SERIAL » [ACK] (0x06) 09:29:10.290 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 230.3 09:29:11.282 SERIAL « 0x010c000400030631050422047b9f (14 bytes) 09:29:11.283 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:29:11.284 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 230.3 => 114.7 [Endpoint 0] 09:29:11.284 SERIAL » [ACK] (0x06) 09:29:11.286 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 114.7 09:29:12.282 SERIAL « 0x010c000400030631050422084ca4 (14 bytes) 09:29:12.284 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:29:12.285 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 114.7 => 212.4 [Endpoint 0] 09:29:12.286 SERIAL » [ACK] (0x06) 09:29:12.287 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 212.4 09:29:13.073 SERIAL « 0x0107001338010606d2 (9 bytes) 09:29:13.073 SERIAL » [ACK] (0x06) 09:29:13.074 DRIVER « [REQ] [SendData] callback id: 56 transmit status: NoAck 09:29:13.080 SERIAL » 0x010800130901002539f0 (10 bytes) 09:29:13.081 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 57 └─[NoOperationCC] 09:29:13.081 CNTRLR [Node 008] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 09:29:13.082 CNTRLR [Node 008] The node is asleep. 09:29:13.083 CNTRLR [Node 008] The node is ready to be used 09:29:13.085 CNTRLR [Node 008] ping failed: Failed to send the command after 1 attempts (Status No Ack) 09:29:13.088 CNTRLR [Node 008] ManufacturerSpecificCC: doing a partial interview... 09:29:13.089 CNTRLR [Node 008] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:29:13.118 SERIAL « [ACK] (0x06) 09:29:13.120 SERIAL « 0x0104011301e8 (6 bytes) 09:29:13.121 SERIAL » [ACK] (0x06) 09:29:13.122 DRIVER « [RES] [SendData] was sent: true 09:29:13.126 SERIAL « 0x0107001339000002d0 (9 bytes) 09:29:13.127 SERIAL » [ACK] (0x06) 09:29:13.128 DRIVER « [REQ] [SendData] callback id: 57 transmit status: OK 09:29:13.134 SERIAL » 0x010800130a0100253af0 (10 bytes) 09:29:13.134 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 58 └─[NoOperationCC] 09:29:13.134 CNTRLR « [Node 009] ping successful 09:29:13.136 CNTRLR [Node 009] ManufacturerSpecificCC: doing a partial interview... 09:29:13.136 CNTRLR [Node 009] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:29:13.137 CNTRLR [Node 009] VersionCC: doing a partial interview... 09:29:13.137 CNTRLR [Node 009] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:29:13.138 CNTRLR [Node 009] trying to load device config 09:29:13.141 SERIAL « [ACK] (0x06) 09:29:13.153 CNTRLR [Node 009] device config loaded 09:29:13.154 CNTRLR [Node 009] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:29:13.155 CNTRLR [Node 009] AssociationCC: doing a partial interview... 09:29:13.155 CNTRLR [Node 009] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 09:29:13.156 CNTRLR [Node 009] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:29:13.156 CNTRLR [Node 009] BinarySwitchCC: doing a partial interview... [Endpoint 1] 09:29:13.157 CNTRLR » [Node 009] querying Binary Switch state... [Endpoint 1] 09:29:13.161 SERIAL « 0x0104011301e8 (6 bytes) 09:29:13.162 SERIAL » [ACK] (0x06) 09:29:13.162 DRIVER « [RES] [SendData] was sent: true 09:29:15.621 CNTRLR [Node 008] VersionCC: doing a partial interview... 09:29:15.622 CNTRLR [Node 008] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:29:15.623 CNTRLR [Node 008] trying to load device config 09:29:15.652 CNTRLR [Node 008] device config loaded 09:29:15.653 CNTRLR [Node 008] BatteryCC: doing a partial interview... 09:29:15.654 CNTRLR » [Node 008] querying battery status... 09:29:20.609 SERIAL « 0x010700133a0102eb39 (9 bytes) 09:29:20.610 SERIAL » [ACK] (0x06) 09:29:20.611 DRIVER « [REQ] [SendData] callback id: 58 transmit status: NoAck 09:29:20.620 SERIAL » 0x010a0013030370052d253ba0 (12 bytes) 09:29:20.621 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 59 └─[ConfigurationCCGet] parameter #: 45 09:29:20.621 CNTRLR [Node 010] Node 10 did not respond after 1 attempts, it is presumed dead 09:29:20.622 CNTRLR [Node 010] The node is dead. 09:29:20.626 CNTRLR [Node 010] ping failed: Failed to send the command after 1 attempts (Status No Ack) 09:29:20.628 CNTRLR [Node 010] ManufacturerSpecificCC: doing a partial interview... 09:29:20.628 CNTRLR [Node 010] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:29:20.677 SERIAL « [ACK] (0x06) 09:29:20.682 SERIAL « 0x0104011301e8 (6 bytes) 09:29:20.683 SERIAL » [ACK] (0x06) 09:29:20.685 DRIVER « [RES] [SendData] was sent: true 09:29:20.688 CNTRLR [Node 010] VersionCC: doing a partial interview... 09:29:20.689 CNTRLR [Node 010] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:29:20.690 CNTRLR [Node 010] trying to load device config 09:29:20.704 CNTRLR [Node 010] device config loaded 09:29:20.705 CNTRLR [Node 010] AssociationCC: doing a partial interview... 09:29:20.706 CNTRLR [Node 010] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 09:29:20.706 CNTRLR [Node 010] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:29:20.707 CNTRLR [Node 010] BinarySwitchCC: doing a partial interview... 09:29:20.707 CNTRLR » [Node 010] querying Binary Switch state... 09:29:20.708 CNTRLR » [Node 010] pinging the node... 09:29:20.713 SERIAL « 0x010700133b000009d9 (9 bytes) 09:29:20.714 SERIAL » [ACK] (0x06) 09:29:20.714 DRIVER « [REQ] [SendData] callback id: 59 transmit status: OK 09:29:20.784 SERIAL « 0x010b000400030570062d010aa6 (13 bytes) 09:29:20.790 CNTRLR [Node 003] [~] [Configuration] 45: 10 => 10 09:29:20.791 SERIAL » [ACK] (0x06) 09:29:20.792 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 45 value size: 1 value: 10 09:29:20.796 SERIAL » 0x010800130a0100253cf6 (10 bytes) 09:29:20.797 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 60 └─[NoOperationCC] 09:29:20.797 CNTRLR « [Node 003] parameter #45 has value: 10 09:29:20.797 CNTRLR » [Node 003] querying parameter #47 value... 09:29:20.801 SERIAL « [ACK] (0x06) 09:29:20.808 SERIAL « 0x0104011301e8 (6 bytes) 09:29:20.809 SERIAL » [ACK] (0x06) 09:29:20.810 DRIVER « [RES] [SendData] was sent: true 09:29:24.943 SERIAL « 0x01090004001b03300300d9 (11 bytes) 09:29:24.944 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:29:24.946 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:29:24.946 SERIAL » [ACK] (0x06) 09:29:24.948 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:29:25.053 SERIAL « 0x01090004101b03300300c9 (11 bytes) 09:29:25.056 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:29:25.058 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:29:25.059 SERIAL » [ACK] (0x06) 09:29:25.063 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:29:25.104 SERIAL « 0x01090004101b03300300c9 (11 bytes) 09:29:25.105 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:29:25.107 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:29:25.108 SERIAL » [ACK] (0x06) 09:29:25.110 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:29:25.118 SERIAL « 0x01090004101b03300300c9 (11 bytes) 09:29:25.119 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:29:25.121 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:29:25.122 SERIAL » [ACK] (0x06) 09:29:25.125 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:29:25.134 SERIAL « 0x01090004101b03300300c9 (11 bytes) 09:29:25.136 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:29:25.137 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:29:25.139 SERIAL » [ACK] (0x06) 09:29:25.142 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:29:25.170 SERIAL « 0x01090004101b03300300c9 (11 bytes) 09:29:25.171 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:29:25.172 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:29:25.173 SERIAL » [ACK] (0x06) 09:29:25.174 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:29:25.377 SERIAL « 0x01090004001b03200100cb (11 bytes) 09:29:25.378 SERIAL » [ACK] (0x06) 09:29:25.379 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:29:25.381 CNTRLR [Node 027] treating BasicCC Set as a report 09:29:25.382 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:29:27.285 SERIAL « 0x010c0004000306310504220439dd (14 bytes) 09:29:27.288 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:29:27.290 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 212.4 => 108.1 [Endpoint 0] 09:29:27.292 SERIAL » [ACK] (0x06) 09:29:27.295 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 108.1 09:29:29.542 SERIAL « 0x010700133c01036bbe (9 bytes) 09:29:29.543 SERIAL » [ACK] (0x06) 09:29:29.547 DRIVER « [REQ] [SendData] callback id: 60 transmit status: NoAck 09:29:29.569 SERIAL » 0x0109001306029840253d21 (11 bytes) 09:29:29.570 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 61 └─[SecurityCCNonceGet] 09:29:29.571 CNTRLR [Node 010] Node 10 did not respond after 1 attempts, it is presumed dead 09:29:29.574 CNTRLR [Node 010] ping failed: Failed to send the command after 1 attempts (Status No Ack) 09:29:29.576 CNTRLR [Node 010] Interview attempt (1/5) failed, node is dead. 09:29:29.579 SERIAL « [ACK] (0x06) 09:29:29.583 SERIAL « 0x0104011301e8 (6 bytes) 09:29:29.584 SERIAL » [ACK] (0x06) 09:29:29.586 DRIVER « [RES] [SendData] was sent: true 09:29:30.493 SERIAL « 0x010c00040003063105042204eb0f (14 bytes) 09:29:30.494 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:29:30.495 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 108.1 => 125.9 [Endpoint 0] 09:29:30.496 SERIAL » [ACK] (0x06) 09:29:30.497 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 125.9 09:29:30.962 SERIAL « 0x010700133d00008b5d (9 bytes) 09:29:30.963 SERIAL » [ACK] (0x06) 09:29:30.965 DRIVER « [REQ] [SendData] callback id: 61 transmit status: OK 09:29:31.049 SERIAL « 0x0110000400060a9880b119de029ddc3ae414 (18 bytes) 09:29:31.051 SERIAL » [ACK] (0x06) 09:29:31.053 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xb119de029ddc3ae4 09:29:31.066 SERIAL » 0x01210013061a9881e93425089196a429e99f79a684da26b195396c4ea91230f22 (35 bytes) 53e3e 09:29:31.068 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 62 └─[SecurityCCCommandEncapsulation] │ nonce id: 177 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BatteryCCGet] 09:29:31.073 SERIAL « [ACK] (0x06) 09:29:31.080 SERIAL « 0x0104011301e8 (6 bytes) 09:29:31.081 SERIAL » [ACK] (0x06) 09:29:31.082 DRIVER « [RES] [SendData] was sent: true 09:29:31.198 SERIAL « 0x010700133e00000cd9 (9 bytes) 09:29:31.199 SERIAL » [ACK] (0x06) 09:29:31.200 DRIVER « [REQ] [SendData] callback id: 62 transmit status: OK 09:29:31.283 SERIAL « 0x010c0004000306310504220416f2 (14 bytes) 09:29:31.285 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:29:31.287 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 125.9 => 104.6 [Endpoint 0] 09:29:31.288 SERIAL » [ACK] (0x06) 09:29:31.292 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 104.6 09:29:31.341 SERIAL « 0x0108000400060298402f (10 bytes) 09:29:31.343 SERIAL » [ACK] (0x06) 09:29:31.344 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:29:31.356 SERIAL » 0x01110013060a98805383f4092d040a3c2400ff (19 bytes) 09:29:31.357 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x5383f4092d040a3c 09:29:31.360 SERIAL « [ACK] (0x06) 09:29:31.366 SERIAL « 0x0104011301e8 (6 bytes) 09:29:31.367 SERIAL » [ACK] (0x06) 09:29:31.369 DRIVER « [RES] [SendData] was sent: true 09:29:31.579 SERIAL « 0x0121000400061b9881a49255530a36bb3c00acb869904a32115328e39c42e6388 (35 bytes) b5597 09:29:31.581 SERIAL » [ACK] (0x06) 09:29:31.584 CNTRLR [Node 006] [~] [Battery] level: 89 => 89 [Endpoint 1] 09:29:31.585 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 1] 09:29:31.587 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BatteryCCReport] level: 89 is low: false 09:29:31.593 SERIAL » 0x010d00130906600d00012502253fbf (15 bytes) 09:29:31.594 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 63 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 09:29:31.596 CNTRLR « [Node 006] received response for battery information: [Endpoint 1] level: 89 09:29:31.597 CNTRLR [Node 006] [~] [Battery] interviewComplete: true => tr [Endpoint 1] [internal] ue 09:29:31.666 SERIAL « [ACK] (0x06) 09:29:31.672 SERIAL « 0x0104011301e8 (6 bytes) 09:29:31.673 SERIAL » [ACK] (0x06) 09:29:31.676 DRIVER « [RES] [SendData] was sent: true 09:29:31.695 CNTRLR [Node 006] ClockCC: doing a partial interview... 09:29:31.696 CNTRLR » [Node 006] requesting current clock setting... 09:29:31.719 SERIAL « 0x010700133f000007d3 (9 bytes) 09:29:31.719 SERIAL » [ACK] (0x06) 09:29:31.721 DRIVER « [REQ] [SendData] callback id: 63 transmit status: OK 09:29:31.725 SERIAL « 0x010d0004000907600d0100250300b2 (15 bytes) 09:29:31.727 CNTRLR [Node 009] [~] [Binary Switch] currentValue: false => false [Endpoint 1] 09:29:31.728 SERIAL » [ACK] (0x06) 09:29:31.730 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: false 09:29:31.737 SERIAL » 0x010a0013030370052f2540d9 (12 bytes) 09:29:31.738 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 64 └─[ConfigurationCCGet] parameter #: 47 09:29:31.739 CNTRLR [Node 009] The node is alive. 09:29:31.740 CNTRLR [Node 009] The node is ready to be used 09:29:31.743 CNTRLR « [Node 009] received Binary Switch state: [Endpoint 1] current value: false 09:29:31.744 CNTRLR [Node 009] [~] [Binary Switch] interviewComplete: true [Endpoint 1] [internal] => true 09:29:31.746 CNTRLR [Node 009] BinarySwitchCC: doing a partial interview... [Endpoint 2] 09:29:31.746 CNTRLR » [Node 009] querying Binary Switch state... [Endpoint 2] 09:29:31.754 SERIAL « [ACK] (0x06) 09:29:31.756 SERIAL « 0x0104011301e8 (6 bytes) 09:29:31.757 SERIAL » [ACK] (0x06) 09:29:31.758 DRIVER « [RES] [SendData] was sent: true 09:29:31.981 SERIAL « 0x0107001340000008a3 (9 bytes) 09:29:31.982 SERIAL » [ACK] (0x06) 09:29:32.025 DRIVER « [REQ] [SendData] callback id: 64 transmit status: OK 09:29:32.032 SERIAL « 0x010c000400030670062f020e10b7 (14 bytes) 09:29:32.037 CNTRLR [Node 003] [~] [Configuration] 47: 3600 => 3600 09:29:32.039 SERIAL » [ACK] (0x06) 09:29:32.040 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 47 value size: 2 value: 3600 09:29:32.046 SERIAL » 0x010900130602984025415d (11 bytes) 09:29:32.047 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 65 └─[SecurityCCNonceGet] 09:29:32.047 CNTRLR « [Node 003] parameter #47 has value: 3600 09:29:32.047 CNTRLR » [Node 003] querying parameter #49 value... 09:29:32.052 SERIAL « [ACK] (0x06) 09:29:32.056 SERIAL « 0x0104011301e8 (6 bytes) 09:29:32.056 SERIAL » [ACK] (0x06) 09:29:32.057 DRIVER « [RES] [SendData] was sent: true 09:29:32.112 SERIAL « 0x0107001341000007ad (9 bytes) 09:29:32.113 SERIAL » [ACK] (0x06) 09:29:32.114 DRIVER « [REQ] [SendData] callback id: 65 transmit status: OK 09:29:32.201 SERIAL « 0x0110000400060a9880c3b81a56a421dbca5c (18 bytes) 09:29:32.201 SERIAL » [ACK] (0x06) 09:29:32.203 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xc3b81a56a421dbca 09:29:32.208 SERIAL » 0x01210013061a988163f27c164724f69b58549273099a99c3eda1cb61b6951d252 (35 bytes) 54283 09:29:32.209 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 66 └─[SecurityCCCommandEncapsulation] │ nonce id: 195 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ClockCCGet] 09:29:32.213 SERIAL « [ACK] (0x06) 09:29:32.220 SERIAL « 0x0104011301e8 (6 bytes) 09:29:32.221 SERIAL » [ACK] (0x06) 09:29:32.222 DRIVER « [RES] [SendData] was sent: true 09:29:32.287 SERIAL « 0x010c0004000306310504220546a3 (14 bytes) 09:29:32.288 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:29:32.293 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 104.6 => 135 [Endpoint 0] 09:29:32.294 SERIAL » [ACK] (0x06) 09:29:32.296 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 135 09:29:32.428 SERIAL « 0x0107001342000015bc (9 bytes) 09:29:32.429 SERIAL » [ACK] (0x06) 09:29:32.430 DRIVER « [REQ] [SendData] callback id: 66 transmit status: OK 09:29:32.506 SERIAL « 0x0108000400060298402f (10 bytes) 09:29:32.507 SERIAL » [ACK] (0x06) 09:29:32.509 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:29:32.517 SERIAL » 0x01110013060a9880a2245f811b4724a4240049 (19 bytes) 09:29:32.518 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xa2245f811b4724a4 09:29:32.522 SERIAL « [ACK] (0x06) 09:29:32.529 SERIAL « 0x0104011301e8 (6 bytes) 09:29:32.529 SERIAL » [ACK] (0x06) 09:29:32.530 DRIVER « [RES] [SendData] was sent: true 09:29:32.750 SERIAL « 0x0122000400061c9881da91fdb5292ef53890c2c8c4b76ffebcfca2b295cd6909a (36 bytes) 274db0e 09:29:32.751 SERIAL » [ACK] (0x06) 09:29:32.753 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ClockCCReport] clock setting: Sunday, 09:23 09:29:32.757 SERIAL » 0x010d00130906600d000225022543c0 (15 bytes) 09:29:32.758 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 67 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[BinarySwitchCCGet] 09:29:32.758 CNTRLR « [Node 006] received current clock setting: Sunday, 09:23 09:29:32.759 CNTRLR [Node 006] [~] [Clock] interviewComplete: true => true [Endpoint 1] [internal] 09:29:32.793 SERIAL « [ACK] (0x06) 09:29:32.797 SERIAL « 0x0104011301e8 (6 bytes) 09:29:32.798 SERIAL » [ACK] (0x06) 09:29:32.799 DRIVER « [RES] [SendData] was sent: true 09:29:32.804 CNTRLR [Node 006] ZWavePlusCC: doing a partial interview... [Endpoint 2] 09:29:32.804 CNTRLR [Node 006] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 09:29:32.805 CNTRLR [Node 006] MultilevelSensorCC: doing a partial interview... [Endpoint 2] 09:29:32.806 CNTRLR » [Node 006] querying Air temperature sensor reading... [Endpoint 2] 09:29:32.839 SERIAL « 0x0107001343000007af (9 bytes) 09:29:32.840 SERIAL » [ACK] (0x06) 09:29:32.841 DRIVER « [REQ] [SendData] callback id: 67 transmit status: OK 09:29:32.849 SERIAL « 0x010d0004000907600d0200250300b1 (15 bytes) 09:29:32.850 CNTRLR [Node 009] [~] [Binary Switch] currentValue: false => false [Endpoint 2] 09:29:32.851 SERIAL » [ACK] (0x06) 09:29:32.853 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BinarySwitchCCReport] current value: false 09:29:32.858 SERIAL » 0x010a001303037005312544c3 (12 bytes) 09:29:32.859 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 68 └─[ConfigurationCCGet] parameter #: 49 09:29:32.860 CNTRLR « [Node 009] received Binary Switch state: [Endpoint 2] current value: false 09:29:32.860 CNTRLR [Node 009] [~] [Binary Switch] interviewComplete: true [Endpoint 2] [internal] => true 09:29:32.861 CNTRLR [Node 009] BinarySwitchCC: doing a partial interview... 09:29:32.861 CNTRLR » [Node 009] querying Binary Switch state... 09:29:32.884 SERIAL « [ACK] (0x06) 09:29:32.886 SERIAL « 0x0104011301e8 (6 bytes) 09:29:32.886 SERIAL » [ACK] (0x06) 09:29:32.887 DRIVER « [RES] [SendData] was sent: true 09:29:32.948 SERIAL « 0x0107001344000008a7 (9 bytes) 09:29:32.948 SERIAL » [ACK] (0x06) 09:29:32.949 DRIVER « [REQ] [SendData] callback id: 68 transmit status: OK 09:29:33.019 SERIAL « 0x010b00040003057006310100b0 (13 bytes) 09:29:33.024 CNTRLR [Node 003] [~] [Configuration] 49: 0 => 0 09:29:33.026 SERIAL » [ACK] (0x06) 09:29:33.027 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 49 value size: 1 value: 0 09:29:33.033 SERIAL » 0x0109001306029840254559 (11 bytes) 09:29:33.034 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 69 └─[SecurityCCNonceGet] 09:29:33.034 CNTRLR « [Node 003] parameter #49 has value: 0 09:29:33.034 CNTRLR » [Node 003] querying parameter #50 value... 09:29:33.042 SERIAL « [ACK] (0x06) 09:29:33.044 SERIAL « 0x0104011301e8 (6 bytes) 09:29:33.044 SERIAL » [ACK] (0x06) 09:29:33.047 DRIVER « [RES] [SendData] was sent: true 09:29:33.157 SERIAL « 0x010700134500000ca2 (9 bytes) 09:29:33.158 SERIAL » [ACK] (0x06) 09:29:33.159 DRIVER « [REQ] [SendData] callback id: 69 transmit status: OK 09:29:33.239 SERIAL « 0x0110000400060a98809602502d0a0d7e4629 (18 bytes) 09:29:33.240 SERIAL » [ACK] (0x06) 09:29:33.241 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x9602502d0a0d7e46 09:29:33.247 SERIAL » 0x01230013061c9881cab7d7ed7695e622654b72558490aa7d4e96e43ef1b9c729a (37 bytes) 48f25468a 09:29:33.248 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 70 └─[SecurityCCCommandEncapsulation] │ nonce id: 150 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:29:33.252 SERIAL « [ACK] (0x06) 09:29:33.259 SERIAL « 0x0104011301e8 (6 bytes) 09:29:33.260 SERIAL » [ACK] (0x06) 09:29:33.261 DRIVER « [RES] [SendData] was sent: true 09:29:33.394 SERIAL « 0x010c000400030631050422076e89 (14 bytes) 09:29:33.395 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:29:33.396 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 135 => 190.2 [Endpoint 0] 09:29:33.397 SERIAL » [ACK] (0x06) 09:29:33.398 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 190.2 09:29:33.629 SERIAL « 0x010700134600002588 (9 bytes) 09:29:33.633 SERIAL » [ACK] (0x06) 09:29:33.634 DRIVER « [REQ] [SendData] callback id: 70 transmit status: OK 09:29:33.707 SERIAL « 0x0108000400060298402f (10 bytes) 09:29:33.708 SERIAL » [ACK] (0x06) 09:29:33.709 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:29:33.714 SERIAL » 0x01110013060a98800dc74f8da974acf1240045 (19 bytes) 09:29:33.715 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x0dc74f8da974acf1 09:29:33.717 SERIAL « [ACK] (0x06) 09:29:33.724 SERIAL « 0x0104011301e8 (6 bytes) 09:29:33.724 SERIAL » [ACK] (0x06) 09:29:33.725 DRIVER « [RES] [SendData] was sent: true 09:29:33.941 SERIAL « 0x0124000400061e9881e18de4771839cfaa28581ae482f84ae269efda0d6287b00 (38 bytes) 054077f0f1e 09:29:33.942 SERIAL » [ACK] (0x06) 09:29:33.945 CNTRLR [Node 006] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:29:33.947 CNTRLR [Node 006] [~] [Multilevel Sensor] Air temperature: 20.9 => 20.8 [Endpoint 2] 09:29:33.948 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 20.8 09:29:33.956 SERIAL » 0x01090013090225022547ab (11 bytes) 09:29:33.957 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 71 └─[BinarySwitchCCGet] 09:29:33.958 CNTRLR « [Node 006] received current Air temperature sensor reading: 20.8 [Endpoint 2] °C 09:29:33.959 CNTRLR [Node 006] [~] [Multilevel Sensor] interviewComplete: [Endpoint 2] [internal] true => true 09:29:34.018 SERIAL « [ACK] (0x06) 09:29:34.025 SERIAL « 0x0104011301e8 (6 bytes) 09:29:34.026 SERIAL » [ACK] (0x06) 09:29:34.031 DRIVER « [RES] [SendData] was sent: true 09:29:34.036 CNTRLR [Node 006] NotificationCC: doing a partial interview... [Endpoint 2] 09:29:34.037 CNTRLR » [Node 006] querying notification status for Power Management... [Endpoint 2] 09:29:34.042 SERIAL « 0x0107001347000006aa (9 bytes) 09:29:34.042 SERIAL » [ACK] (0x06) 09:29:34.044 DRIVER « [REQ] [SendData] callback id: 71 transmit status: OK 09:29:34.049 SERIAL « 0x01090004000903250300de (11 bytes) 09:29:34.050 CNTRLR [Node 009] [~] [Binary Switch] currentValue: false => false [Endpoint 0] 09:29:34.052 SERIAL » [ACK] (0x06) 09:29:34.053 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 09:29:34.060 SERIAL » 0x010a001303037005322548cc (12 bytes) 09:29:34.061 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 72 └─[ConfigurationCCGet] parameter #: 50 09:29:34.061 CNTRLR « [Node 009] received Binary Switch state: current value: false 09:29:34.062 CNTRLR [Node 009] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 09:29:34.062 CNTRLR [Node 009] ConfigurationCC: Loading configuration parameters from device confi g 09:29:34.068 CNTRLR [Node 009] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:29:34.069 CNTRLR [Node 009] [Configuration] 1: metadata updated 09:29:34.071 CNTRLR [Node 009] [Configuration] 3: metadata updated 09:29:34.073 CNTRLR [Node 009] [Configuration] 4: metadata updated 09:29:34.074 CNTRLR [Node 009] [Configuration] 5: metadata updated 09:29:34.076 CNTRLR [Node 009] [Configuration] 6: metadata updated 09:29:34.077 CNTRLR [Node 009] [Configuration] 7: metadata updated 09:29:34.079 CNTRLR [Node 009] [Configuration] 13: metadata updated 09:29:34.080 CNTRLR [Node 009] [Configuration] 14: metadata updated 09:29:34.082 CNTRLR [Node 009] [Configuration] 15: metadata updated 09:29:34.083 CNTRLR [Node 009] [Configuration] 16: metadata updated 09:29:34.085 CNTRLR [Node 009] [Configuration] 30: metadata updated 09:29:34.094 CNTRLR [Node 009] [Configuration] 31: metadata updated 09:29:34.095 CNTRLR [Node 009] [Configuration] 32: metadata updated 09:29:34.097 CNTRLR [Node 009] [Configuration] 33: metadata updated 09:29:34.099 CNTRLR [Node 009] [Configuration] 39: metadata updated 09:29:34.101 CNTRLR [Node 009] [Configuration] 40: metadata updated 09:29:34.106 CNTRLR [Node 009] [Configuration] 41: metadata updated 09:29:34.108 CNTRLR [Node 009] [Configuration] 42: metadata updated 09:29:34.110 CNTRLR [Node 009] [Configuration] 43: metadata updated 09:29:34.111 CNTRLR [Node 009] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:29:34.112 CNTRLR » [Node 009] querying parameter #1 value... 09:29:34.123 SERIAL « [ACK] (0x06) 09:29:34.125 SERIAL « 0x0104011301e8 (6 bytes) 09:29:34.125 SERIAL » [ACK] (0x06) 09:29:34.147 DRIVER « [RES] [SendData] was sent: true 09:29:34.173 SERIAL « 0x0107001348000008ab (9 bytes) 09:29:34.174 SERIAL » [ACK] (0x06) 09:29:34.182 DRIVER « [REQ] [SendData] callback id: 72 transmit status: OK 09:29:34.226 SERIAL « 0x010c000400030670063202012c99 (14 bytes) 09:29:34.232 CNTRLR [Node 003] [~] [Configuration] 50: 300 => 300 09:29:34.233 SERIAL » [ACK] (0x06) 09:29:34.234 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 2 value: 300 09:29:34.241 SERIAL » 0x0109001306029840254955 (11 bytes) 09:29:34.242 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 73 └─[SecurityCCNonceGet] 09:29:34.242 CNTRLR « [Node 003] parameter #50 has value: 300 09:29:34.243 CNTRLR » [Node 003] querying parameter #51 value... 09:29:34.248 SERIAL « [ACK] (0x06) 09:29:34.251 SERIAL « 0x0104011301e8 (6 bytes) 09:29:34.251 SERIAL » [ACK] (0x06) 09:29:34.254 DRIVER « [RES] [SendData] was sent: true 09:29:34.349 SERIAL « 0x010700134900000aa8 (9 bytes) 09:29:34.350 SERIAL » [ACK] (0x06) 09:29:34.351 DRIVER « [REQ] [SendData] callback id: 73 transmit status: OK 09:29:34.430 SERIAL « 0x0110000400060a9880fcebc80bbd539d2870 (18 bytes) 09:29:34.431 SERIAL » [ACK] (0x06) 09:29:34.432 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xfcebc80bbd539d28 09:29:34.436 SERIAL » 0x01240013061d98819023a7182530e400def06d99d25a3dcbbf64fc59a29fb1ffe (38 bytes) 06dde254aa2 09:29:34.437 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 74 └─[SecurityCCCommandEncapsulation] │ nonce id: 252 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: Power Management 09:29:34.440 SERIAL « [ACK] (0x06) 09:29:34.448 SERIAL « 0x0104011301e8 (6 bytes) 09:29:34.448 SERIAL » [ACK] (0x06) 09:29:34.449 DRIVER « [RES] [SendData] was sent: true 09:29:34.571 SERIAL « 0x010700134a00000dac (9 bytes) 09:29:34.572 SERIAL » [ACK] (0x06) 09:29:34.573 DRIVER « [REQ] [SendData] callback id: 74 transmit status: OK 09:29:34.656 SERIAL « 0x0108000400060298402f (10 bytes) 09:29:34.657 SERIAL » [ACK] (0x06) 09:29:34.658 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:29:34.663 SERIAL » 0x01110013060a9880ed8e9d9fc88256c0240070 (19 bytes) 09:29:34.664 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xed8e9d9fc88256c0 09:29:34.666 SERIAL « [ACK] (0x06) 09:29:34.672 SERIAL « 0x0104011301e8 (6 bytes) 09:29:34.673 SERIAL » [ACK] (0x06) 09:29:34.673 DRIVER « [RES] [SendData] was sent: true 09:29:34.893 SERIAL « 0x012700040006219881e6fa27075a5cf7b946a355b8ad7ce9a96d81f2d9bd67edb (41 bytes) 703dfd6e8a8beb60a 09:29:34.895 SERIAL » [ACK] (0x06) 09:29:34.898 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 09:29:34.907 SERIAL » 0x010a00130903700501254bf6 (12 bytes) 09:29:34.908 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 75 └─[ConfigurationCCGet] parameter #: 1 09:29:34.911 CNTRLR [Node 006] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 2] 54 09:29:34.913 CNTRLR » [Node 006] querying notification status for System... [Endpoint 2] 09:29:34.923 SERIAL « [ACK] (0x06) 09:29:34.926 SERIAL « 0x0104011301e8 (6 bytes) 09:29:34.927 SERIAL » [ACK] (0x06) 09:29:34.929 DRIVER « [RES] [SendData] was sent: true 09:29:34.977 SERIAL « 0x010700134b000006a6 (9 bytes) 09:29:34.978 SERIAL » [ACK] (0x06) 09:29:34.980 DRIVER « [REQ] [SendData] callback id: 75 transmit status: OK 09:29:34.987 SERIAL « 0x010b000400090570060101ff75 (13 bytes) 09:29:34.998 CNTRLR [Node 009] [~] [Configuration] 1: 255 => 255 09:29:34.999 SERIAL » [ACK] (0x06) 09:29:35.000 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 255 09:29:35.007 SERIAL » 0x010a00130303700533254cc9 (12 bytes) 09:29:35.008 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 76 └─[ConfigurationCCGet] parameter #: 51 09:29:35.008 CNTRLR « [Node 009] parameter #1 has value: 255 09:29:35.008 CNTRLR » [Node 009] querying parameter #3 value... 09:29:35.023 SERIAL « [ACK] (0x06) 09:29:35.026 SERIAL « 0x0104011301e8 (6 bytes) 09:29:35.026 SERIAL » [ACK] (0x06) 09:29:35.027 DRIVER « [RES] [SendData] was sent: true 09:29:35.096 SERIAL « 0x010700134c000008af (9 bytes) 09:29:35.096 SERIAL » [ACK] (0x06) 09:29:35.097 DRIVER « [REQ] [SendData] callback id: 76 transmit status: OK 09:29:35.168 SERIAL « 0x010c00040003067006330201f440 (14 bytes) 09:29:35.173 CNTRLR [Node 003] [~] [Configuration] 51: 500 => 500 09:29:35.174 SERIAL » [ACK] (0x06) 09:29:35.175 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 51 value size: 2 value: 500 09:29:35.181 SERIAL » 0x0109001306029840254d51 (11 bytes) 09:29:35.181 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 77 └─[SecurityCCNonceGet] 09:29:35.182 CNTRLR « [Node 003] parameter #51 has value: 500 09:29:35.182 CNTRLR » [Node 003] querying parameter #52 value... 09:29:35.187 SERIAL « [ACK] (0x06) 09:29:35.190 SERIAL « 0x0104011301e8 (6 bytes) 09:29:35.190 SERIAL » [ACK] (0x06) 09:29:35.192 DRIVER « [RES] [SendData] was sent: true 09:29:35.308 SERIAL « 0x010700134d00000caa (9 bytes) 09:29:35.308 SERIAL » [ACK] (0x06) 09:29:35.309 DRIVER « [REQ] [SendData] callback id: 77 transmit status: OK 09:29:35.390 SERIAL « 0x0110000400060a98806344743e5369b6213f (18 bytes) 09:29:35.391 SERIAL » [ACK] (0x06) 09:29:35.392 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x6344743e5369b621 09:29:35.395 SERIAL » 0x01240013061d9881ddcf46735002de9d6f1cc1c18a758b783dca635f7bfd2fff6 (38 bytes) 76cfc254e82 09:29:35.396 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 78 └─[SecurityCCCommandEncapsulation] │ nonce id: 99 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:29:35.399 SERIAL « [ACK] (0x06) 09:29:35.407 SERIAL « 0x0104011301e8 (6 bytes) 09:29:35.407 SERIAL » [ACK] (0x06) 09:29:35.408 DRIVER « [RES] [SendData] was sent: true 09:29:35.529 SERIAL « 0x010700134e00000ca9 (9 bytes) 09:29:35.529 SERIAL » [ACK] (0x06) 09:29:35.530 DRIVER « [REQ] [SendData] callback id: 78 transmit status: OK 09:29:37.138 CNTRLR [Node 006] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:29:37.645 SERIAL » 0x0109001306029840254f53 (11 bytes) 09:29:37.646 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 79 └─[SecurityCCNonceGet] 09:29:37.647 SERIAL « [ACK] (0x06) 09:29:37.659 SERIAL « 0x0104011301e8 (6 bytes) 09:29:37.660 SERIAL » [ACK] (0x06) 09:29:37.660 DRIVER « [RES] [SendData] was sent: true 09:29:39.025 SERIAL « 0x010700134f00008a2e (9 bytes) 09:29:39.025 SERIAL » [ACK] (0x06) 09:29:39.026 DRIVER « [REQ] [SendData] callback id: 79 transmit status: OK 09:29:39.109 SERIAL « 0x0110000400060a9880919806049178c1c814 (18 bytes) 09:29:39.110 SERIAL » [ACK] (0x06) 09:29:39.112 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x919806049178c1c8 09:29:39.121 SERIAL » 0x01240013061d9881236453d93bee07696b0865c26b6fed76c15a91cbee8784b12 (38 bytes) edbb6254e52 09:29:39.122 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 78 └─[SecurityCCCommandEncapsulation] │ nonce id: 145 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:29:39.126 SERIAL « [ACK] (0x06) 09:29:39.135 SERIAL « 0x0104011301e8 (6 bytes) 09:29:39.135 SERIAL » [ACK] (0x06) 09:29:39.137 DRIVER « [RES] [SendData] was sent: true 09:29:39.249 SERIAL « 0x010700134e00000ca9 (9 bytes) 09:29:39.250 SERIAL » [ACK] (0x06) 09:29:39.253 DRIVER « [REQ] [SendData] callback id: 78 transmit status: OK 09:29:40.863 CNTRLR [Node 006] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:29:41.375 SERIAL » 0x010900130602984025504c (11 bytes) 09:29:41.376 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 80 └─[SecurityCCNonceGet] 09:29:41.378 SERIAL « [ACK] (0x06) 09:29:41.384 SERIAL « 0x0104011301e8 (6 bytes) 09:29:41.385 SERIAL » [ACK] (0x06) 09:29:41.386 DRIVER « [RES] [SendData] was sent: true 09:29:42.773 SERIAL « 0x010700135000008c37 (9 bytes) 09:29:42.774 SERIAL » [ACK] (0x06) 09:29:42.776 DRIVER « [REQ] [SendData] callback id: 80 transmit status: OK 09:29:42.856 SERIAL « 0x0110000400060a98806453b81cc5b1f6e50b (18 bytes) 09:29:42.856 SERIAL » [ACK] (0x06) 09:29:42.857 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x6453b81cc5b1f6e5 09:29:42.865 SERIAL » 0x01240013061d9881660195e60041c4dc525348ceb17d2ca72cf5640178b40346a (38 bytes) 0d9e2254e82 09:29:42.865 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 78 └─[SecurityCCCommandEncapsulation] │ nonce id: 100 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:29:42.869 SERIAL « [ACK] (0x06) 09:29:42.876 SERIAL « 0x0104011301e8 (6 bytes) 09:29:42.877 SERIAL » [ACK] (0x06) 09:29:42.878 DRIVER « [RES] [SendData] was sent: true 09:29:42.999 SERIAL « 0x010700134e00000ca9 (9 bytes) 09:29:42.999 SERIAL » [ACK] (0x06) 09:29:43.000 DRIVER « [REQ] [SendData] callback id: 78 transmit status: OK 09:29:44.610 SERIAL » 0x010a001309037005032551ee (12 bytes) 09:29:44.611 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 81 └─[ConfigurationCCGet] parameter #: 3 09:29:44.612 CNTRLR [Node 006] Interview attempt 1/5 failed, retrying in 5000 ms... 09:29:44.614 SERIAL « [ACK] (0x06) 09:29:44.620 SERIAL « 0x0104011301e8 (6 bytes) 09:29:44.620 SERIAL » [ACK] (0x06) 09:29:44.621 DRIVER « [RES] [SendData] was sent: true 09:29:44.637 SERIAL « 0x0107001351000002b8 (9 bytes) 09:29:44.638 SERIAL » [ACK] (0x06) 09:29:44.639 DRIVER « [REQ] [SendData] callback id: 81 transmit status: OK 09:29:44.648 SERIAL « 0x010b0004000905700603010088 (13 bytes) 09:29:44.658 CNTRLR [Node 009] [~] [Configuration] 3: 0 => 0 09:29:44.660 SERIAL » [ACK] (0x06) 09:29:44.663 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 09:29:44.670 SERIAL » 0x010a001303037005342552d0 (12 bytes) 09:29:44.671 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 82 └─[ConfigurationCCGet] parameter #: 52 09:29:44.671 CNTRLR « [Node 009] parameter #3 has value: 0 09:29:44.672 CNTRLR » [Node 009] querying parameter #4 value... 09:29:44.679 SERIAL « [ACK] (0x06) 09:29:44.682 SERIAL « 0x0104011301e8 (6 bytes) 09:29:44.683 SERIAL » [ACK] (0x06) 09:29:44.685 DRIVER « [RES] [SendData] was sent: true 09:29:44.759 SERIAL « 0x0107001352000008b1 (9 bytes) 09:29:44.759 SERIAL » [ACK] (0x06) 09:29:44.760 DRIVER « [REQ] [SendData] callback id: 82 transmit status: OK 09:29:44.830 SERIAL « 0x010b00040003057006340106b3 (13 bytes) 09:29:44.836 CNTRLR [Node 003] [~] [Configuration] 52: 6 => 6 09:29:44.837 SERIAL » [ACK] (0x06) 09:29:44.838 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 52 value size: 1 value: 6 09:29:44.842 SERIAL » 0x010a001309037005042553eb (12 bytes) 09:29:44.842 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 83 └─[ConfigurationCCGet] parameter #: 4 09:29:44.843 CNTRLR « [Node 003] parameter #52 has value: 6 09:29:44.843 CNTRLR » [Node 003] querying parameter #60 value... 09:29:44.852 SERIAL « [ACK] (0x06) 09:29:44.855 SERIAL « 0x0104011301e8 (6 bytes) 09:29:44.855 SERIAL » [ACK] (0x06) 09:29:44.856 DRIVER « [RES] [SendData] was sent: true 09:29:44.926 SERIAL « 0x0107001353000008b0 (9 bytes) 09:29:44.927 SERIAL » [ACK] (0x06) 09:29:44.927 DRIVER « [REQ] [SendData] callback id: 83 transmit status: OK 09:29:44.937 SERIAL « 0x010c000400090670060402000088 (14 bytes) 09:29:44.942 CNTRLR [Node 009] [~] [Configuration] 4: 0 => 0 09:29:44.944 SERIAL » [ACK] (0x06) 09:29:44.945 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 2 value: 0 09:29:44.948 SERIAL » 0x010a0013030370053c2554de (12 bytes) 09:29:44.949 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 84 └─[ConfigurationCCGet] parameter #: 60 09:29:44.949 CNTRLR « [Node 009] parameter #4 has value: 0 09:29:44.949 CNTRLR » [Node 009] querying parameter #5 value... 09:29:44.958 SERIAL « [ACK] (0x06) 09:29:44.961 SERIAL « 0x0104011301e8 (6 bytes) 09:29:44.961 SERIAL » [ACK] (0x06) 09:29:44.962 DRIVER « [RES] [SendData] was sent: true 09:29:45.038 SERIAL « 0x0107001354000008b7 (9 bytes) 09:29:45.038 SERIAL » [ACK] (0x06) 09:29:45.039 DRIVER « [REQ] [SendData] callback id: 84 transmit status: OK 09:29:45.110 SERIAL « 0x010c000400030670063c0261a873 (14 bytes) 09:29:45.116 CNTRLR [Node 003] [~] [Configuration] 60: 25000 => 25000 09:29:45.117 SERIAL » [ACK] (0x06) 09:29:45.118 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 2 value: 25000 09:29:45.122 SERIAL » 0x010a001309037005052555ec (12 bytes) 09:29:45.122 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 85 └─[ConfigurationCCGet] parameter #: 5 09:29:45.124 CNTRLR « [Node 003] parameter #60 has value: 25000 09:29:45.124 CNTRLR » [Node 003] querying parameter #61 value... 09:29:45.128 SERIAL « [ACK] (0x06) 09:29:45.133 SERIAL « 0x0104011301e8 (6 bytes) 09:29:45.133 SERIAL » [ACK] (0x06) 09:29:45.134 DRIVER « [RES] [SendData] was sent: true 09:29:45.206 SERIAL « 0x0107001355000008b6 (9 bytes) 09:29:45.207 SERIAL » [ACK] (0x06) 09:29:45.207 DRIVER « [REQ] [SendData] callback id: 85 transmit status: OK 09:29:45.219 SERIAL « 0x010c000400090670060502000089 (14 bytes) 09:29:45.224 CNTRLR [Node 009] [~] [Configuration] 5: 0 => 0 09:29:45.241 SERIAL » [ACK] (0x06) 09:29:45.242 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 2 value: 0 09:29:45.250 SERIAL » 0x010a0013030370053d2556dd (12 bytes) 09:29:45.251 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 86 └─[ConfigurationCCGet] parameter #: 61 09:29:45.251 CNTRLR « [Node 009] parameter #5 has value: 0 09:29:45.252 CNTRLR » [Node 009] querying parameter #6 value... 09:29:45.257 SERIAL « [ACK] (0x06) 09:29:45.260 SERIAL « 0x0104011301e8 (6 bytes) 09:29:45.260 SERIAL » [ACK] (0x06) 09:29:45.262 DRIVER « [RES] [SendData] was sent: true 09:29:45.338 SERIAL « 0x0107001356000008b5 (9 bytes) 09:29:45.339 SERIAL » [ACK] (0x06) 09:29:45.339 DRIVER « [REQ] [SendData] callback id: 86 transmit status: OK 09:29:45.410 SERIAL « 0x010b000400030570063d0101bd (13 bytes) 09:29:45.418 CNTRLR [Node 003] [~] [Configuration] 61: 1 => 1 09:29:45.419 SERIAL » [ACK] (0x06) 09:29:45.420 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 61 value size: 1 value: 1 09:29:45.424 SERIAL » 0x010a001309037005062557ed (12 bytes) 09:29:45.425 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 87 └─[ConfigurationCCGet] parameter #: 6 09:29:45.425 CNTRLR « [Node 003] parameter #61 has value: 1 09:29:45.425 CNTRLR » [Node 003] querying parameter #62 value... 09:29:45.431 SERIAL « [ACK] (0x06) 09:29:45.435 SERIAL « 0x0104011301e8 (6 bytes) 09:29:45.435 SERIAL » [ACK] (0x06) 09:29:45.436 DRIVER « [RES] [SendData] was sent: true 09:29:45.507 SERIAL « 0x0107001357000008b4 (9 bytes) 09:29:45.507 SERIAL » [ACK] (0x06) 09:29:45.508 DRIVER « [REQ] [SendData] callback id: 87 transmit status: OK 09:29:45.517 SERIAL « 0x010b000400090570060601008d (13 bytes) 09:29:45.525 CNTRLR [Node 009] [~] [Configuration] 6: 0 => 0 09:29:45.527 SERIAL » [ACK] (0x06) 09:29:45.529 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 1 value: 0 09:29:45.538 SERIAL » 0x010a0013030370053e2558d0 (12 bytes) 09:29:45.538 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 88 └─[ConfigurationCCGet] parameter #: 62 09:29:45.539 CNTRLR « [Node 009] parameter #6 has value: 0 09:29:45.539 CNTRLR » [Node 009] querying parameter #7 value... 09:29:45.547 SERIAL « [ACK] (0x06) 09:29:45.551 SERIAL « 0x0104011301e8 (6 bytes) 09:29:45.552 SERIAL » [ACK] (0x06) 09:29:45.554 DRIVER « [RES] [SendData] was sent: true 09:29:45.627 SERIAL « 0x0107001358000008bb (9 bytes) 09:29:45.627 SERIAL » [ACK] (0x06) 09:29:45.628 DRIVER « [REQ] [SendData] callback id: 88 transmit status: OK 09:29:45.698 SERIAL « 0x010b000400030570063e0108b7 (13 bytes) 09:29:45.708 CNTRLR [Node 003] [~] [Configuration] 62: 8 => 8 09:29:45.710 SERIAL » [ACK] (0x06) 09:29:45.712 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 62 value size: 1 value: 8 09:29:45.722 SERIAL » 0x010a001309037005072559e2 (12 bytes) 09:29:45.723 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 89 └─[ConfigurationCCGet] parameter #: 7 09:29:45.723 CNTRLR « [Node 003] parameter #62 has value: 8 09:29:45.724 CNTRLR » [Node 003] querying parameter #63 value... 09:29:45.735 SERIAL « [ACK] (0x06) 09:29:45.740 SERIAL « 0x0104011301e8 (6 bytes) 09:29:45.740 SERIAL » [ACK] (0x06) 09:29:45.742 DRIVER « [RES] [SendData] was sent: true 09:29:45.786 SERIAL « 0x0107001359000006b4 (9 bytes) 09:29:45.787 SERIAL » [ACK] (0x06) 09:29:45.787 DRIVER « [REQ] [SendData] callback id: 89 transmit status: OK 09:29:45.797 SERIAL « 0x010b000400090570060701008c (13 bytes) 09:29:45.803 CNTRLR [Node 009] [~] [Configuration] 7: 0 => 0 09:29:45.804 SERIAL » [ACK] (0x06) 09:29:45.805 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 7 value size: 1 value: 0 09:29:45.809 SERIAL » 0x010a0013030370053f255ad3 (12 bytes) 09:29:45.810 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 90 └─[ConfigurationCCGet] parameter #: 63 09:29:45.810 CNTRLR « [Node 009] parameter #7 has value: 0 09:29:45.810 CNTRLR » [Node 009] querying parameter #13 value... 09:29:45.815 SERIAL « [ACK] (0x06) 09:29:45.818 SERIAL « 0x0104011301e8 (6 bytes) 09:29:45.819 SERIAL » [ACK] (0x06) 09:29:45.821 DRIVER « [RES] [SendData] was sent: true 09:29:45.897 SERIAL « 0x010700135a000008b9 (9 bytes) 09:29:45.897 SERIAL » [ACK] (0x06) 09:29:45.898 DRIVER « [REQ] [SendData] callback id: 90 transmit status: OK 09:29:45.993 SERIAL « 0x010b000400030570063f0101bf (13 bytes) 09:29:45.999 CNTRLR [Node 003] [~] [Configuration] 63: 1 => 1 09:29:46.000 SERIAL » [ACK] (0x06) 09:29:46.001 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 63 value size: 1 value: 1 09:29:46.005 SERIAL » 0x010a0013090370050d255bea (12 bytes) 09:29:46.006 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 91 └─[ConfigurationCCGet] parameter #: 13 09:29:46.006 CNTRLR « [Node 003] parameter #63 has value: 1 09:29:46.006 CNTRLR » [Node 003] querying parameter #70 value... 09:29:46.010 SERIAL « [ACK] (0x06) 09:29:46.014 SERIAL « 0x0104011301e8 (6 bytes) 09:29:46.015 SERIAL » [ACK] (0x06) 09:29:46.016 DRIVER « [RES] [SendData] was sent: true 09:29:46.087 SERIAL « 0x010700135b000008b8 (9 bytes) 09:29:46.089 SERIAL » [ACK] (0x06) 09:29:46.090 DRIVER « [REQ] [SendData] callback id: 91 transmit status: OK 09:29:46.097 SERIAL « 0x010b000400090570060d010086 (13 bytes) 09:29:46.112 CNTRLR [Node 009] [~] [Configuration] 13: 0 => 0 09:29:46.113 SERIAL » [ACK] (0x06) 09:29:46.115 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 0 09:29:46.120 SERIAL » 0x010a00130303700546255cac (12 bytes) 09:29:46.121 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 92 └─[ConfigurationCCGet] parameter #: 70 09:29:46.121 CNTRLR « [Node 009] parameter #13 has value: 0 09:29:46.122 CNTRLR » [Node 009] querying parameter #14 value... 09:29:46.127 SERIAL « [ACK] (0x06) 09:29:46.129 SERIAL « 0x0104011301e8 (6 bytes) 09:29:46.130 SERIAL » [ACK] (0x06) 09:29:46.131 DRIVER « [RES] [SendData] was sent: true 09:29:46.208 SERIAL « 0x010700135c000008bf (9 bytes) 09:29:46.209 SERIAL » [ACK] (0x06) 09:29:46.209 DRIVER « [REQ] [SendData] callback id: 92 transmit status: OK 09:29:46.281 SERIAL « 0x010c000400030670064602ffffc0 (14 bytes) 09:29:46.286 CNTRLR [Node 003] [~] [Configuration] 70: 65535 => 65535 09:29:46.287 SERIAL » [ACK] (0x06) 09:29:46.288 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 70 value size: 2 value: 65535 09:29:46.294 SERIAL » 0x010a0013090370050e255def (12 bytes) 09:29:46.294 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 93 └─[ConfigurationCCGet] parameter #: 14 09:29:46.296 CNTRLR « [Node 003] parameter #70 has value: 65535 09:29:46.297 CNTRLR [Node 003] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 09:29:46.343 SERIAL « [ACK] (0x06) 09:29:46.349 SERIAL « 0x0104011301e8 (6 bytes) 09:29:46.349 SERIAL » [ACK] (0x06) 09:29:46.350 DRIVER « [RES] [SendData] was sent: true 09:29:46.355 CNTRLR [Node 003] MultiChannelAssociationCC: doing a partial interview... 09:29:46.355 CNTRLR » [Node 003] querying multi channel association group #1... 09:29:46.397 SERIAL « 0x010700135d000008be (9 bytes) 09:29:46.398 SERIAL » [ACK] (0x06) 09:29:46.398 DRIVER « [REQ] [SendData] callback id: 93 transmit status: OK 09:29:46.402 SERIAL « 0x010b000400090570060e010184 (13 bytes) 09:29:46.408 CNTRLR [Node 009] [~] [Configuration] 14: 1 => 1 09:29:46.409 SERIAL » [ACK] (0x06) 09:29:46.410 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 1 09:29:46.419 SERIAL » 0x010800130b0100255e95 (10 bytes) 09:29:46.419 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 94 └─[NoOperationCC] 09:29:46.420 CNTRLR « [Node 009] parameter #14 has value: 1 09:29:46.420 CNTRLR » [Node 009] querying parameter #15 value... 09:29:46.426 SERIAL « [ACK] (0x06) 09:29:46.428 SERIAL « 0x0104011301e8 (6 bytes) 09:29:46.428 SERIAL » [ACK] (0x06) 09:29:46.429 DRIVER « [RES] [SendData] was sent: true 09:29:49.613 CNTRLR [Node 006] Beginning interview - last completed stage: RestartFromCache 09:29:49.614 CNTRLR » [Node 006] pinging the node... 09:29:54.115 SERIAL « 0x010700135e010301b6 (9 bytes) 09:29:54.116 SERIAL » [ACK] (0x06) 09:29:54.118 DRIVER « [REQ] [SendData] callback id: 94 transmit status: NoAck 09:29:54.130 SERIAL » 0x010800130c0100255f93 (10 bytes) 09:29:54.131 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 95 └─[NoOperationCC] 09:29:54.131 CNTRLR [Node 011] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 09:29:54.133 CNTRLR [Node 011] The node is asleep. 09:29:54.136 CNTRLR [Node 011] The node is ready to be used 09:29:54.140 CNTRLR [Node 011] ping failed: Failed to send the command after 1 attempts (Status No Ack) 09:29:54.145 CNTRLR [Node 011] ManufacturerSpecificCC: doing a partial interview... 09:29:54.146 CNTRLR [Node 011] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:29:54.226 SERIAL « [ACK] (0x06) 09:29:54.233 SERIAL « 0x0104011301e8 (6 bytes) 09:29:54.233 SERIAL » [ACK] (0x06) 09:29:54.243 DRIVER « [RES] [SendData] was sent: true 09:29:54.247 SERIAL « 0x010700135f000006b2 (9 bytes) 09:29:54.248 SERIAL » [ACK] (0x06) 09:29:54.248 CNTRLR [Node 011] VersionCC: doing a partial interview... 09:29:54.249 CNTRLR [Node 011] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:29:54.249 CNTRLR [Node 011] trying to load device config 09:29:54.250 DRIVER « [REQ] [SendData] callback id: 95 transmit status: OK 09:29:54.256 SERIAL » 0x010800130d01002560ad (10 bytes) 09:29:54.256 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 96 └─[NoOperationCC] 09:29:54.257 CNTRLR « [Node 012] ping successful 09:29:54.260 CNTRLR [Node 012] ManufacturerSpecificCC: doing a partial interview... 09:29:54.261 CNTRLR [Node 012] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:29:54.262 CNTRLR [Node 012] VersionCC: doing a partial interview... 09:29:54.262 CNTRLR [Node 012] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:29:54.263 CNTRLR [Node 012] trying to load device config 09:29:54.267 SERIAL « [ACK] (0x06) 09:29:54.269 SERIAL « 0x0104011301e8 (6 bytes) 09:29:54.269 SERIAL » [ACK] (0x06) 09:29:54.270 DRIVER « [RES] [SendData] was sent: true 09:29:54.274 CNTRLR [Node 011] device config loaded 09:29:54.275 CNTRLR [Node 011] BatteryCC: doing a partial interview... 09:29:54.275 CNTRLR » [Node 011] querying battery status... 09:29:54.289 CNTRLR [Node 012] device config loaded 09:29:54.290 CNTRLR [Node 012] AssociationCC: doing a partial interview... 09:29:54.290 CNTRLR » [Node 012] querying association group #1... 09:29:54.353 SERIAL « 0x01070013600000058e (9 bytes) 09:29:54.353 SERIAL » [ACK] (0x06) 09:29:54.354 DRIVER « [REQ] [SendData] callback id: 96 transmit status: OK 09:29:54.364 SERIAL » 0x010800130e01002561af (10 bytes) 09:29:54.364 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 97 └─[NoOperationCC] 09:29:54.365 CNTRLR « [Node 013] ping successful 09:29:54.366 CNTRLR [Node 013] ManufacturerSpecificCC: doing a partial interview... 09:29:54.367 CNTRLR [Node 013] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:29:54.367 CNTRLR [Node 013] VersionCC: doing a partial interview... 09:29:54.367 CNTRLR [Node 013] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:29:54.368 CNTRLR [Node 013] trying to load device config 09:29:54.552 SERIAL « [ACK] (0x06) 09:29:54.553 SERIAL « 0x0104011301e8 (6 bytes) 09:29:54.553 SERIAL » [ACK] (0x06) 09:29:54.555 DRIVER « [RES] [SendData] was sent: true 09:29:54.623 CNTRLR [Node 013] device config loaded 09:29:54.624 CNTRLR [Node 013] AssociationCC: doing a partial interview... 09:29:54.625 CNTRLR [Node 013] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 09:29:54.625 CNTRLR [Node 013] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:29:54.626 CNTRLR [Node 013] BinarySwitchCC: doing a partial interview... 09:29:54.626 CNTRLR » [Node 013] querying Binary Switch state... 09:29:54.631 SERIAL « 0x010700136100000288 (9 bytes) 09:29:54.631 SERIAL » [ACK] (0x06) 09:29:54.632 DRIVER « [REQ] [SendData] callback id: 97 transmit status: OK 09:29:54.649 SERIAL » 0x010800130f01002562ad (10 bytes) 09:29:54.649 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 98 └─[NoOperationCC] 09:29:54.650 CNTRLR « [Node 014] ping successful 09:29:54.652 CNTRLR [Node 014] ManufacturerSpecificCC: doing a partial interview... 09:29:54.653 CNTRLR [Node 014] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:29:54.653 CNTRLR [Node 014] VersionCC: doing a partial interview... 09:29:54.654 CNTRLR [Node 014] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:29:54.655 CNTRLR [Node 014] trying to load device config 09:29:54.660 SERIAL « [ACK] (0x06) 09:29:54.662 SERIAL « 0x0104011301e8 (6 bytes) 09:29:54.662 SERIAL » [ACK] (0x06) 09:29:54.664 DRIVER « [RES] [SendData] was sent: true 09:29:54.690 CNTRLR [Node 014] device config loaded 09:29:54.691 CNTRLR [Node 014] AssociationCC: doing a partial interview... 09:29:54.692 CNTRLR [Node 014] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 09:29:54.692 CNTRLR [Node 014] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:29:54.693 CNTRLR [Node 014] BinarySwitchCC: doing a partial interview... 09:29:54.693 CNTRLR » [Node 014] querying Binary Switch state... 09:29:54.697 SERIAL « 0x01070013620000028b (9 bytes) 09:29:54.697 SERIAL » [ACK] (0x06) 09:29:54.703 DRIVER « [REQ] [SendData] callback id: 98 transmit status: OK 09:29:54.710 SERIAL » 0x010800131001002563b3 (10 bytes) 09:29:54.710 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 99 └─[NoOperationCC] 09:29:54.710 CNTRLR « [Node 015] ping successful 09:29:54.712 CNTRLR [Node 015] ManufacturerSpecificCC: doing a partial interview... 09:29:54.712 CNTRLR [Node 015] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:29:54.712 CNTRLR [Node 015] VersionCC: doing a partial interview... 09:29:54.713 CNTRLR [Node 015] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:29:54.713 CNTRLR [Node 015] trying to load device config 09:29:54.717 SERIAL « [ACK] (0x06) 09:29:54.718 SERIAL « 0x0104011301e8 (6 bytes) 09:29:54.719 SERIAL » [ACK] (0x06) 09:29:54.723 DRIVER « [RES] [SendData] was sent: true 09:29:54.740 CNTRLR [Node 015] device config loaded 09:29:54.740 CNTRLR [Node 015] AssociationCC: doing a partial interview... 09:29:54.741 CNTRLR [Node 015] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 09:29:54.741 CNTRLR [Node 015] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:29:54.742 CNTRLR [Node 015] BinarySwitchCC: doing a partial interview... 09:29:54.742 CNTRLR » [Node 015] querying Binary Switch state... 09:29:54.756 SERIAL « 0x01070013630000048c (9 bytes) 09:29:54.756 SERIAL » [ACK] (0x06) 09:29:54.757 DRIVER « [REQ] [SendData] callback id: 99 transmit status: OK 09:29:54.763 SERIAL » 0x010800130601002564a2 (10 bytes) 09:29:54.763 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 100 └─[NoOperationCC] 09:29:54.764 CNTRLR « [Node 016] ping successful 09:29:54.765 CNTRLR [Node 016] ManufacturerSpecificCC: doing a partial interview... 09:29:54.766 CNTRLR [Node 016] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:29:54.767 CNTRLR [Node 016] VersionCC: doing a partial interview... 09:29:54.767 CNTRLR [Node 016] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:29:54.768 CNTRLR [Node 016] trying to load device config 09:29:54.773 SERIAL « [ACK] (0x06) 09:29:54.775 SERIAL « 0x0104011301e8 (6 bytes) 09:29:54.775 SERIAL » [ACK] (0x06) 09:29:54.777 DRIVER « [RES] [SendData] was sent: true 09:29:54.788 CNTRLR [Node 016] device config loaded 09:29:54.789 CNTRLR [Node 016] AssociationCC: doing a partial interview... 09:29:54.790 CNTRLR » [Node 016] querying association group #1... 09:29:56.211 SERIAL « 0x01070013640000911e (9 bytes) 09:29:56.212 SERIAL » [ACK] (0x06) 09:29:56.213 DRIVER « [REQ] [SendData] callback id: 100 transmit status: OK 09:29:56.229 SERIAL » 0x010a0013090370050f2565d6 (12 bytes) 09:29:56.231 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 101 └─[ConfigurationCCGet] parameter #: 15 09:29:56.232 CNTRLR « [Node 006] ping successful 09:29:56.291 SERIAL « [ACK] (0x06) 09:29:56.295 SERIAL « 0x0104011301e8 (6 bytes) 09:29:56.295 SERIAL » [ACK] (0x06) 09:29:56.298 DRIVER « [RES] [SendData] was sent: true 09:29:56.303 CNTRLR [Node 006] ManufacturerSpecificCC: doing a partial interview... 09:29:56.303 CNTRLR [Node 006] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:29:56.304 CNTRLR [Node 006] VersionCC: doing a partial interview... 09:29:56.304 CNTRLR [Node 006] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:29:56.304 CNTRLR [Node 006] trying to load device config 09:29:56.306 SERIAL « 0x01070013650000028c (9 bytes) 09:29:56.307 SERIAL » [ACK] (0x06) 09:29:56.308 DRIVER « [REQ] [SendData] callback id: 101 transmit status: OK 09:29:56.310 SERIAL « 0x010b000400090570060f010084 (13 bytes) 09:29:56.316 CNTRLR [Node 009] [~] [Configuration] 15: 0 => 0 09:29:56.317 SERIAL » [ACK] (0x06) 09:29:56.319 CNTRLR [Node 006] device config loaded 09:29:56.320 CNTRLR [Node 006] ZWavePlusCC: doing a partial interview... 09:29:56.320 CNTRLR [Node 006] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:29:56.321 CNTRLR » [Node 006] querying device endpoint information... 09:29:56.323 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 15 value size: 1 value: 0 09:29:56.327 SERIAL » 0x010a00130c0385020125662c (12 bytes) 09:29:56.328 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 102 └─[AssociationCCGet] group id: 1 09:29:56.329 CNTRLR « [Node 009] parameter #15 has value: 0 09:29:56.329 CNTRLR » [Node 009] querying parameter #16 value... 09:29:56.333 SERIAL « [ACK] (0x06) 09:29:56.336 SERIAL « 0x0104011301e8 (6 bytes) 09:29:56.337 SERIAL » [ACK] (0x06) 09:29:56.338 DRIVER « [RES] [SendData] was sent: true 09:29:56.399 SERIAL « 0x01070013660000068b (9 bytes) 09:29:56.399 SERIAL » [ACK] (0x06) 09:29:56.400 DRIVER « [REQ] [SendData] callback id: 102 transmit status: OK 09:29:56.453 SERIAL « 0x010b0004000c0585030110006e (13 bytes) 09:29:56.454 SERIAL » [ACK] (0x06) 09:29:56.485 CNTRLR [Node 012] [~] [Association] maxNodes[1]: 16 => 16 [internal] 09:29:56.485 CNTRLR [Node 012] [~] [Association] nodeIds[1]: => [internal] 09:29:56.486 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 1 max # of nodes: 16 node IDs: reports to follow: 0 09:29:56.500 SERIAL » 0x010900130d02250225678f (11 bytes) 09:29:56.501 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 103 └─[BinarySwitchCCGet] 09:29:56.501 CNTRLR [Node 012] The node is alive. 09:29:56.503 CNTRLR [Node 012] The node is ready to be used 09:29:56.504 CNTRLR « [Node 012] received information for association group #1: maximum # of nodes: 16 currently assigned nodes: 09:29:56.505 CNTRLR » [Node 012] querying association group #2... 09:29:56.512 SERIAL « [ACK] (0x06) 09:29:56.513 SERIAL « 0x0104011301e8 (6 bytes) 09:29:56.513 SERIAL » [ACK] (0x06) 09:29:56.515 DRIVER « [RES] [SendData] was sent: true 09:29:56.557 SERIAL « 0x010700136700000589 (9 bytes) 09:29:56.558 SERIAL » [ACK] (0x06) 09:29:56.559 DRIVER « [REQ] [SendData] callback id: 103 transmit status: OK 09:29:56.802 SERIAL « 0x01090004000d032503fe24 (11 bytes) 09:29:56.803 CNTRLR [Node 013] [~] [Binary Switch] currentValue: "unknown" => "unknow [Endpoint 0] n" 09:29:56.803 SERIAL » [ACK] (0x06) 09:29:56.804 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: unknown 09:29:56.808 SERIAL » 0x010900130e022502256883 (11 bytes) 09:29:56.809 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 104 └─[BinarySwitchCCGet] 09:29:56.809 CNTRLR [Node 013] The node is alive. 09:29:56.810 CNTRLR [Node 013] The node is ready to be used 09:29:56.811 CNTRLR « [Node 013] received Binary Switch state: current value: unknown 09:29:56.812 CNTRLR [Node 013] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 09:29:56.843 SERIAL « [ACK] (0x06) 09:29:56.846 SERIAL « 0x0104011301e8 (6 bytes) 09:29:56.846 SERIAL » [ACK] (0x06) 09:29:56.849 DRIVER « [RES] [SendData] was sent: true 09:29:56.854 CNTRLR [Node 013] MultilevelSwitchCC: doing a partial interview... 09:29:56.854 CNTRLR » [Node 013] requesting current switch state... 09:29:56.923 SERIAL « 0x010700136800000281 (9 bytes) 09:29:56.924 SERIAL » [ACK] (0x06) 09:29:56.930 DRIVER « [REQ] [SendData] callback id: 104 transmit status: OK 09:29:56.941 SERIAL « 0x01090004000e032503fe27 (11 bytes) 09:29:56.943 CNTRLR [Node 014] [~] [Binary Switch] currentValue: "unknown" => "unknow [Endpoint 0] n" 09:29:56.944 SERIAL » [ACK] (0x06) 09:29:56.947 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: unknown 09:29:56.954 SERIAL » 0x010900130f022502256983 (11 bytes) 09:29:56.955 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 105 └─[BinarySwitchCCGet] 09:29:56.956 CNTRLR [Node 014] The node is alive. 09:29:56.957 CNTRLR [Node 014] The node is ready to be used 09:29:56.959 CNTRLR « [Node 014] received Binary Switch state: current value: unknown 09:29:56.960 CNTRLR [Node 014] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 09:29:56.961 CNTRLR [Node 014] MultilevelSwitchCC: doing a partial interview... 09:29:56.961 CNTRLR » [Node 014] requesting current switch state... 09:29:56.984 SERIAL « [ACK] (0x06) 09:29:56.986 SERIAL « 0x0104011301e8 (6 bytes) 09:29:56.987 SERIAL » [ACK] (0x06) 09:29:57.223 DRIVER « [RES] [SendData] was sent: true 09:29:57.265 SERIAL « 0x010700136900000280 (9 bytes) 09:29:57.266 SERIAL » [ACK] (0x06) 09:29:57.268 DRIVER « [REQ] [SendData] callback id: 105 transmit status: OK 09:29:57.272 SERIAL « 0x01090004000f03250300d8 (11 bytes) 09:29:57.273 CNTRLR [Node 015] [~] [Binary Switch] currentValue: false => false [Endpoint 0] 09:29:57.274 SERIAL » [ACK] (0x06) 09:29:57.276 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 09:29:57.280 SERIAL » 0x010a00131003850201256a3c (12 bytes) 09:29:57.281 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 106 └─[AssociationCCGet] group id: 1 09:29:57.281 CNTRLR [Node 015] The node is alive. 09:29:57.282 CNTRLR [Node 015] The node is ready to be used 09:29:57.284 CNTRLR « [Node 015] received Binary Switch state: current value: false 09:29:57.284 CNTRLR [Node 015] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 09:29:57.285 CNTRLR [Node 015] MultilevelSensorCC: doing a partial interview... 09:29:57.285 CNTRLR » [Node 015] querying current sensor reading... 09:29:57.538 SERIAL « [ACK] (0x06) 09:29:57.539 SERIAL « 0x0104011301e8 (6 bytes) 09:29:57.539 SERIAL » [ACK] (0x06) 09:29:57.550 DRIVER « [RES] [SendData] was sent: true 09:29:57.558 SERIAL « 0x010700136a00000485 (9 bytes) 09:29:57.559 SERIAL » [ACK] (0x06) 09:29:57.560 DRIVER « [REQ] [SendData] callback id: 106 transmit status: OK 09:29:57.563 SERIAL « 0x010b0004001005850301100072 (13 bytes) 09:29:57.564 SERIAL » [ACK] (0x06) 09:29:57.565 CNTRLR [Node 016] [~] [Association] maxNodes[1]: 16 => 16 [internal] 09:29:57.566 CNTRLR [Node 016] [~] [Association] nodeIds[1]: => [internal] 09:29:57.566 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 1 max # of nodes: 16 node IDs: reports to follow: 0 09:29:57.573 SERIAL » 0x0109001306029840256b77 (11 bytes) 09:29:57.573 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 107 └─[SecurityCCNonceGet] 09:29:57.574 CNTRLR [Node 016] The node is alive. 09:29:57.575 CNTRLR [Node 016] The node is ready to be used 09:29:57.577 CNTRLR « [Node 016] received information for association group #1: maximum # of nodes: 16 currently assigned nodes: 09:29:57.577 CNTRLR » [Node 016] querying association group #2... 09:29:57.585 SERIAL « [ACK] (0x06) 09:29:57.586 SERIAL « 0x0104011301e8 (6 bytes) 09:29:57.587 SERIAL » [ACK] (0x06) 09:29:57.589 DRIVER « [RES] [SendData] was sent: true 09:29:57.805 SERIAL « 0x010700136b00000787 (9 bytes) 09:29:57.805 SERIAL » [ACK] (0x06) 09:29:57.813 DRIVER « [REQ] [SendData] callback id: 107 transmit status: OK 09:29:57.817 SERIAL « 0x0110000400060a9880fad11d0030d0317f67 (18 bytes) 09:29:57.818 SERIAL » [ACK] (0x06) 09:29:57.819 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xfad11d0030d0317f 09:29:57.825 SERIAL » 0x011d001306169881bccadfff8ee75de33ddfeffa28337cbe5f70bdc6256c4a (31 bytes) 09:29:57.826 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 108 └─[SecurityCCCommandEncapsulation] │ nonce id: 250 └─[MultiChannelCCEndPointGet] 09:29:57.829 SERIAL « [ACK] (0x06) 09:29:57.840 SERIAL « 0x0104011301e8 (6 bytes) 09:29:57.840 SERIAL » [ACK] (0x06) 09:29:58.058 DRIVER « [RES] [SendData] was sent: true 09:29:58.062 SERIAL « 0x010700136c00000780 (9 bytes) 09:29:58.063 SERIAL » [ACK] (0x06) 09:29:58.064 DRIVER « [REQ] [SendData] callback id: 108 transmit status: OK 09:29:58.067 SERIAL « 0x0108000400060298402f (10 bytes) 09:29:58.067 SERIAL » [ACK] (0x06) 09:29:58.068 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:29:58.074 SERIAL » 0x01110013060a98804aeece28415d17b1240035 (19 bytes) 09:29:58.075 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x4aeece28415d17b1 09:29:58.081 SERIAL « [ACK] (0x06) 09:29:58.087 SERIAL « 0x0104011301e8 (6 bytes) 09:29:58.088 SERIAL » [ACK] (0x06) 09:29:58.089 DRIVER « [RES] [SendData] was sent: true 09:29:58.240 SERIAL « 0x011f0004000619988128915be22e59716d945ba48c86f14a1df61eb9268858ac4 (33 bytes) 5 09:29:58.242 SERIAL » [ACK] (0x06) 09:29:58.244 CNTRLR [Node 006] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:29:58.245 CNTRLR [Node 006] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 09:29:58.246 CNTRLR [Node 006] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:29:58.246 CNTRLR [Node 006] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 09:29:58.247 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:29:58.250 SERIAL » 0x010a00130903700510256dc1 (12 bytes) 09:29:58.251 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 109 └─[ConfigurationCCGet] parameter #: 16 09:29:58.251 CNTRLR « [Node 006] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:29:58.252 CNTRLR » [Node 006] querying all endpoints... 09:29:58.264 SERIAL « [ACK] (0x06) 09:29:58.265 SERIAL « 0x0104011301e8 (6 bytes) 09:29:58.266 SERIAL » [ACK] (0x06) 09:29:58.268 DRIVER « [RES] [SendData] was sent: true 09:29:58.337 SERIAL « 0x010700136d0000088e (9 bytes) 09:29:58.337 SERIAL » [ACK] (0x06) 09:29:58.338 DRIVER « [REQ] [SendData] callback id: 109 transmit status: OK 09:29:58.358 SERIAL « 0x010b000400090570061001019a (13 bytes) 09:29:58.364 CNTRLR [Node 009] [~] [Configuration] 16: 1 => 1 09:29:58.366 SERIAL » [ACK] (0x06) 09:29:58.368 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 1 09:29:58.372 SERIAL » 0x010a00130c03850202256e27 (12 bytes) 09:29:58.373 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 110 └─[AssociationCCGet] group id: 2 09:29:58.373 CNTRLR « [Node 009] parameter #16 has value: 1 09:29:58.374 CNTRLR » [Node 009] querying parameter #30 value... 09:29:58.382 SERIAL « [ACK] (0x06) 09:29:58.383 SERIAL « 0x0104011301e8 (6 bytes) 09:29:58.383 SERIAL » [ACK] (0x06) 09:29:58.387 DRIVER « [RES] [SendData] was sent: true 09:29:58.444 SERIAL « 0x010700136e00000782 (9 bytes) 09:29:58.445 SERIAL » [ACK] (0x06) 09:29:58.447 DRIVER « [REQ] [SendData] callback id: 110 transmit status: OK 09:29:58.498 SERIAL « 0x010b0004000c0585030210006d (13 bytes) 09:29:58.499 SERIAL » [ACK] (0x06) 09:29:58.501 CNTRLR [Node 012] [~] [Association] maxNodes[2]: 16 => 16 [internal] 09:29:58.502 CNTRLR [Node 012] [~] [Association] nodeIds[2]: => [internal] 09:29:58.502 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 2 max # of nodes: 16 node IDs: reports to follow: 0 09:29:58.506 SERIAL » 0x010900130d022602256f84 (11 bytes) 09:29:58.507 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 111 └─[MultilevelSwitchCCGet] 09:29:58.507 CNTRLR « [Node 012] received information for association group #2: maximum # of nodes: 16 currently assigned nodes: 09:29:58.508 CNTRLR » [Node 012] querying association group #3... 09:29:58.514 SERIAL « [ACK] (0x06) 09:29:58.517 SERIAL « 0x0104011301e8 (6 bytes) 09:29:58.517 SERIAL » [ACK] (0x06) 09:29:58.518 DRIVER « [RES] [SendData] was sent: true 09:29:58.608 SERIAL « 0x010700136f00000a8e (9 bytes) 09:29:58.609 SERIAL » [ACK] (0x06) 09:29:58.611 DRIVER « [REQ] [SendData] callback id: 111 transmit status: OK 09:29:58.655 SERIAL « 0x01090004000d03260301d8 (11 bytes) 09:29:58.656 CNTRLR [Node 013] [~] [Multilevel Switch] currentValue: 1 => 1 [Endpoint 0] 09:29:58.657 SERIAL » [ACK] (0x06) 09:29:58.659 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 1 09:29:58.673 SERIAL » 0x010900130e022602257098 (11 bytes) 09:29:58.674 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 112 └─[MultilevelSwitchCCGet] 09:29:58.675 CNTRLR [Node 013] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 09:29:58.708 SERIAL « [ACK] (0x06) 09:29:58.710 SERIAL « 0x0104011301e8 (6 bytes) 09:29:58.710 SERIAL » [ACK] (0x06) 09:29:58.716 DRIVER « [RES] [SendData] was sent: true 09:29:58.727 CNTRLR [Node 013] MultilevelSensorCC: doing a partial interview... 09:29:58.727 CNTRLR » [Node 013] querying current sensor reading... 09:29:58.744 SERIAL « 0x01070013700000069d (9 bytes) 09:29:58.745 SERIAL » [ACK] (0x06) 09:29:58.746 DRIVER « [REQ] [SendData] callback id: 112 transmit status: OK 09:29:58.752 SERIAL « 0x01090004000e03260301db (11 bytes) 09:29:58.753 CNTRLR [Node 014] [~] [Multilevel Switch] currentValue: 1 => 1 [Endpoint 0] 09:29:58.754 SERIAL » [ACK] (0x06) 09:29:58.757 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 1 09:29:58.761 SERIAL » 0x010900130f023104257189 (11 bytes) 09:29:58.761 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 113 └─[MultilevelSensorCCGet] 09:29:58.762 CNTRLR [Node 014] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 09:29:58.762 CNTRLR [Node 014] MultilevelSensorCC: doing a partial interview... 09:29:58.763 CNTRLR » [Node 014] querying current sensor reading... 09:29:58.769 SERIAL « [ACK] (0x06) 09:29:58.773 SERIAL « 0x0104011301e8 (6 bytes) 09:29:58.774 SERIAL » [ACK] (0x06) 09:29:58.776 DRIVER « [RES] [SendData] was sent: true 09:29:58.790 SERIAL « 0x010700137100000298 (9 bytes) 09:29:58.790 SERIAL » [ACK] (0x06) 09:29:58.791 DRIVER « [REQ] [SendData] callback id: 113 transmit status: OK 09:29:58.797 SERIAL « 0x010c0004000f06310504220000ec (14 bytes) 09:29:58.798 CNTRLR [Node 015] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:29:58.799 CNTRLR [Node 015] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 09:29:58.800 SERIAL » [ACK] (0x06) 09:29:58.801 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 09:29:58.809 SERIAL » 0x010a00131003850202257227 (12 bytes) 09:29:58.810 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 114 └─[AssociationCCGet] group id: 2 09:29:58.810 CNTRLR « [Node 015] received current sensor reading: sensor type: Power value: 0 W 09:29:58.811 CNTRLR [Node 015] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 09:29:58.811 CNTRLR [Node 015] MeterCC: doing a partial interview... 09:29:58.812 CNTRLR » [Node 015] querying meter value (type = Electric, scale = kWh)... 09:29:58.817 SERIAL « [ACK] (0x06) 09:29:58.819 SERIAL « 0x0104011301e8 (6 bytes) 09:29:58.819 SERIAL » [ACK] (0x06) 09:29:58.821 DRIVER « [RES] [SendData] was sent: true 09:29:58.858 SERIAL « 0x01070013720000049d (9 bytes) 09:29:58.859 SERIAL » [ACK] (0x06) 09:29:58.860 DRIVER « [REQ] [SendData] callback id: 114 transmit status: OK 09:29:58.906 SERIAL « 0x010b0004001005850302100071 (13 bytes) 09:29:58.907 SERIAL » [ACK] (0x06) 09:29:58.910 CNTRLR [Node 016] [~] [Association] maxNodes[2]: 16 => 16 [internal] 09:29:58.910 CNTRLR [Node 016] [~] [Association] nodeIds[2]: => [internal] 09:29:58.910 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 2 max # of nodes: 16 node IDs: reports to follow: 0 09:29:58.916 SERIAL » 0x010900130602984025736f (11 bytes) 09:29:58.916 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 115 └─[SecurityCCNonceGet] 09:29:58.917 CNTRLR « [Node 016] received information for association group #2: maximum # of nodes: 16 currently assigned nodes: 09:29:58.917 CNTRLR » [Node 016] querying association group #3... 09:29:58.948 SERIAL « [ACK] (0x06) 09:29:58.952 SERIAL « 0x0104011301e8 (6 bytes) 09:29:58.953 SERIAL » [ACK] (0x06) 09:29:58.956 DRIVER « [RES] [SendData] was sent: true 09:30:00.340 SERIAL « 0x010700137300008d15 (9 bytes) 09:30:00.340 SERIAL » [ACK] (0x06) 09:30:00.341 DRIVER « [REQ] [SendData] callback id: 115 transmit status: OK 09:30:00.421 SERIAL « 0x0110000400060a98804a26d3b633a8ebb93f (18 bytes) 09:30:00.421 SERIAL » [ACK] (0x06) 09:30:00.422 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x4a26d3b633a8ebb9 09:30:00.435 SERIAL » 0x011f001306189881d4dd79bea6a50a0af75dae17374afea791d5efb1507f25746 (33 bytes) a 09:30:00.438 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 116 └─[SecurityCCCommandEncapsulation] │ nonce id: 74 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:30:00.441 SERIAL « [ACK] (0x06) 09:30:00.448 SERIAL « 0x0104011301e8 (6 bytes) 09:30:00.448 SERIAL » [ACK] (0x06) 09:30:00.449 DRIVER « [RES] [SendData] was sent: true 09:30:00.558 SERIAL « 0x010700137400000b94 (9 bytes) 09:30:00.559 SERIAL » [ACK] (0x06) 09:30:00.559 DRIVER « [REQ] [SendData] callback id: 116 transmit status: OK 09:30:00.636 SERIAL « 0x0108000400060298402f (10 bytes) 09:30:00.637 SERIAL » [ACK] (0x06) 09:30:00.638 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:30:00.642 SERIAL » 0x01110013060a9880a7e33f6789e35a2c2400cd (19 bytes) 09:30:00.643 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xa7e33f6789e35a2c 09:30:00.645 SERIAL « [ACK] (0x06) 09:30:00.651 SERIAL « 0x0104011301e8 (6 bytes) 09:30:00.652 SERIAL » [ACK] (0x06) 09:30:00.652 DRIVER « [RES] [SendData] was sent: true 09:30:00.870 SERIAL « 0x0121000400061b98810f5f8750aaa71d44a9ad063347685751a7d3972137b7f83 (35 bytes) 6f76e 09:30:00.871 SERIAL » [ACK] (0x06) 09:30:00.873 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 09:30:00.876 SERIAL » 0x010a0013090370051e2575d7 (12 bytes) 09:30:00.877 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 117 └─[ConfigurationCCGet] parameter #: 30 09:30:00.877 CNTRLR « [Node 006] received endpoints: 1, 2 09:30:00.877 CNTRLR » [Node 006] querying capabilities for endpoint #1... 09:30:00.881 SERIAL « [ACK] (0x06) 09:30:00.885 SERIAL « 0x0104011301e8 (6 bytes) 09:30:00.885 SERIAL » [ACK] (0x06) 09:30:00.886 DRIVER « [RES] [SendData] was sent: true 09:30:00.956 SERIAL « 0x010700137500000896 (9 bytes) 09:30:00.957 SERIAL » [ACK] (0x06) 09:30:00.958 DRIVER « [REQ] [SendData] callback id: 117 transmit status: OK 09:30:00.967 SERIAL « 0x010b000400090570061e010396 (13 bytes) 09:30:00.973 CNTRLR [Node 009] [~] [Configuration] 30: 3 => 3 09:30:00.975 SERIAL » [ACK] (0x06) 09:30:00.976 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 3 09:30:00.980 SERIAL » 0x010a00130c0385020325763e (12 bytes) 09:30:00.980 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 118 └─[AssociationCCGet] group id: 3 09:30:00.981 CNTRLR « [Node 009] parameter #30 has value: 3 09:30:00.981 CNTRLR » [Node 009] querying parameter #31 value... 09:30:00.985 SERIAL « [ACK] (0x06) 09:30:00.990 SERIAL « 0x0104011301e8 (6 bytes) 09:30:00.991 SERIAL » [ACK] (0x06) 09:30:00.992 DRIVER « [RES] [SendData] was sent: true 09:30:01.052 SERIAL « 0x01070013760000079a (9 bytes) 09:30:01.052 SERIAL » [ACK] (0x06) 09:30:01.053 DRIVER « [REQ] [SendData] callback id: 118 transmit status: OK 09:30:01.106 SERIAL « 0x010c0004000c0685030301000178 (14 bytes) 09:30:01.107 SERIAL » [ACK] (0x06) 09:30:01.109 CNTRLR [Node 012] [~] [Association] maxNodes[3]: 1 => 1 [internal] 09:30:01.109 CNTRLR [Node 012] [~] [Association] nodeIds[3]: 1 => 1 [internal] 09:30:01.110 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 09:30:01.116 SERIAL » 0x010900130d02310425778d (11 bytes) 09:30:01.117 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 119 └─[MultilevelSensorCCGet] 09:30:01.117 CNTRLR « [Node 012] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 09:30:01.119 CNTRLR [Node 012] [~] [Association] hasLifeline: true => true [internal] 09:30:01.120 CNTRLR [Node 012] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:30:01.165 SERIAL « [ACK] (0x06) 09:30:01.170 SERIAL « 0x0104011301e8 (6 bytes) 09:30:01.170 SERIAL » [ACK] (0x06) 09:30:01.171 DRIVER « [RES] [SendData] was sent: true 09:30:01.175 CNTRLR [Node 012] BinarySwitchCC: doing a partial interview... 09:30:01.175 CNTRLR » [Node 012] querying Binary Switch state... 09:30:01.217 SERIAL « 0x010700137700000a96 (9 bytes) 09:30:01.218 SERIAL » [ACK] (0x06) 09:30:01.218 DRIVER « [REQ] [SendData] callback id: 119 transmit status: OK 09:30:01.266 SERIAL « 0x010c0004000d06310504220000ee (14 bytes) 09:30:01.267 CNTRLR [Node 013] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:30:01.272 CNTRLR [Node 013] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 09:30:01.273 SERIAL » [ACK] (0x06) 09:30:01.275 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 09:30:01.280 SERIAL » 0x010900130e023104257881 (11 bytes) 09:30:01.280 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 120 └─[MultilevelSensorCCGet] 09:30:01.281 CNTRLR « [Node 013] received current sensor reading: sensor type: Power value: 0 W 09:30:01.282 CNTRLR [Node 013] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 09:30:01.283 CNTRLR [Node 013] MeterCC: doing a partial interview... 09:30:01.283 CNTRLR » [Node 013] querying meter value (type = Electric, scale = kWh)... 09:30:01.289 SERIAL « [ACK] (0x06) 09:30:01.291 SERIAL « 0x0104011301e8 (6 bytes) 09:30:01.295 SERIAL » [ACK] (0x06) 09:30:01.296 DRIVER « [RES] [SendData] was sent: true 09:30:01.356 SERIAL « 0x010700137800000794 (9 bytes) 09:30:01.357 SERIAL » [ACK] (0x06) 09:30:01.358 DRIVER « [REQ] [SendData] callback id: 120 transmit status: OK 09:30:01.367 SERIAL « 0x010c0004000e06310504220000ed (14 bytes) 09:30:01.368 CNTRLR [Node 014] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:30:01.370 CNTRLR [Node 014] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 09:30:01.370 SERIAL » [ACK] (0x06) 09:30:01.372 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 09:30:01.378 SERIAL » 0x010a00130f03320100257985 (12 bytes) 09:30:01.379 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 121 └─[MeterCCGet] duration: kWh 09:30:01.379 CNTRLR « [Node 014] received current sensor reading: sensor type: Power value: 0 W 09:30:01.380 CNTRLR [Node 014] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 09:30:01.433 SERIAL « [ACK] (0x06) 09:30:01.434 SERIAL « 0x0104011301e8 (6 bytes) 09:30:01.435 SERIAL » [ACK] (0x06) 09:30:01.439 DRIVER « [RES] [SendData] was sent: true 09:30:01.443 CNTRLR [Node 014] MeterCC: doing a partial interview... 09:30:01.444 CNTRLR » [Node 014] querying meter value (type = Electric, scale = kWh)... 09:30:01.447 SERIAL « 0x010700137900000290 (9 bytes) 09:30:01.448 SERIAL » [ACK] (0x06) 09:30:01.448 DRIVER « [REQ] [SendData] callback id: 121 transmit status: OK 09:30:01.452 SERIAL « 0x01100004000f0a32022144000067a8000074 (18 bytes) 09:30:01.455 CNTRLR [Node 015] [~] [Meter] value[65537]: 265.36 => 265.36 [Endpoint 0] 09:30:01.457 CNTRLR [Node 015] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 09:30:01.458 SERIAL » [ACK] (0x06) 09:30:01.460 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 265.36 time delta: 0 seconds 09:30:01.464 SERIAL » 0x010a00131003850203257a2e (12 bytes) 09:30:01.464 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 122 └─[AssociationCCGet] group id: 3 09:30:01.465 CNTRLR » [Node 015] querying meter value (type = Electric, scale = W)... 09:30:01.469 SERIAL « [ACK] (0x06) 09:30:01.472 SERIAL « 0x0104011301e8 (6 bytes) 09:30:01.473 SERIAL » [ACK] (0x06) 09:30:01.473 DRIVER « [RES] [SendData] was sent: true 09:30:01.511 SERIAL « 0x010700137a00000594 (9 bytes) 09:30:01.512 SERIAL » [ACK] (0x06) 09:30:01.512 DRIVER « [REQ] [SendData] callback id: 122 transmit status: OK 09:30:01.560 SERIAL « 0x010c000400100685030301000164 (14 bytes) 09:30:01.561 SERIAL » [ACK] (0x06) 09:30:01.562 CNTRLR [Node 016] [~] [Association] maxNodes[3]: 1 => 1 [internal] 09:30:01.562 CNTRLR [Node 016] [~] [Association] nodeIds[3]: 1 => 1 [internal] 09:30:01.563 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 09:30:01.568 SERIAL » 0x0109001306029840257b67 (11 bytes) 09:30:01.568 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 123 └─[SecurityCCNonceGet] 09:30:01.569 CNTRLR « [Node 016] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 09:30:01.570 CNTRLR [Node 016] [~] [Association] hasLifeline: true => true [internal] 09:30:01.570 CNTRLR [Node 016] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:30:01.570 CNTRLR [Node 016] BinarySwitchCC: doing a partial interview... 09:30:01.571 CNTRLR » [Node 016] querying Binary Switch state... 09:30:01.574 SERIAL « [ACK] (0x06) 09:30:01.577 SERIAL « 0x0104011301e8 (6 bytes) 09:30:01.577 SERIAL » [ACK] (0x06) 09:30:01.578 DRIVER « [RES] [SendData] was sent: true 09:30:02.965 SERIAL « 0x010700137b00008b1b (9 bytes) 09:30:02.966 SERIAL » [ACK] (0x06) 09:30:02.967 DRIVER « [REQ] [SendData] callback id: 123 transmit status: OK 09:30:03.049 SERIAL « 0x0110000400060a988079c87245694e7a2c08 (18 bytes) 09:30:03.050 SERIAL » [ACK] (0x06) 09:30:03.052 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x79c87245694e7a2c 09:30:03.073 SERIAL » 0x011e001306179881b3b6ac83eee8a1ee67ecfb0d79906cfbfda91458a5257c7e (32 bytes) 09:30:03.075 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 124 └─[SecurityCCCommandEncapsulation] │ nonce id: 121 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:30:03.079 SERIAL « [ACK] (0x06) 09:30:03.086 SERIAL « 0x0104011301e8 (6 bytes) 09:30:03.087 SERIAL » [ACK] (0x06) 09:30:03.088 DRIVER « [RES] [SendData] was sent: true 09:30:03.188 SERIAL « 0x010700137c00000a9d (9 bytes) 09:30:03.189 SERIAL » [ACK] (0x06) 09:30:03.189 DRIVER « [REQ] [SendData] callback id: 124 transmit status: OK 09:30:03.275 SERIAL « 0x0108000400060298402f (10 bytes) 09:30:03.275 SERIAL » [ACK] (0x06) 09:30:03.277 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:30:03.287 SERIAL » 0x01110013060a9880ad46235baca0e3b4240005 (19 bytes) 09:30:03.288 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xad46235baca0e3b4 09:30:03.291 SERIAL « [ACK] (0x06) 09:30:03.297 SERIAL « 0x0104011301e8 (6 bytes) 09:30:03.298 SERIAL » [ACK] (0x06) 09:30:03.299 DRIVER « [RES] [SendData] was sent: true 09:30:03.518 SERIAL « 0x0123000400061d9881c6aad5a432cc064bbd5852ee80487a58be15adef237c7fd (37 bytes) 69ed771e0 09:30:03.520 SERIAL » [ACK] (0x06) 09:30:03.525 CNTRLR [Node 006] [~] [Multi Channel] commandClasses: 94,152, [Endpoint 1] [internal] 159,34 => 94,152,159,34 09:30:03.526 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 09:30:03.534 SERIAL » 0x010a0013090370051f257dde (12 bytes) 09:30:03.535 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 125 └─[ConfigurationCCGet] parameter #: 31 09:30:03.535 CNTRLR « [Node 006] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 09:30:03.536 CNTRLR » [Node 006] querying capabilities for endpoint #2... 09:30:03.542 SERIAL « [ACK] (0x06) 09:30:03.544 SERIAL « 0x0104011301e8 (6 bytes) 09:30:03.545 SERIAL » [ACK] (0x06) 09:30:03.546 DRIVER « [RES] [SendData] was sent: true 09:30:03.606 SERIAL « 0x010700137d00000791 (9 bytes) 09:30:03.607 SERIAL » [ACK] (0x06) 09:30:03.608 DRIVER « [REQ] [SendData] callback id: 125 transmit status: OK 09:30:03.617 SERIAL « 0x010b000400090570061f010296 (13 bytes) 09:30:03.627 CNTRLR [Node 009] [~] [Configuration] 31: 2 => 2 09:30:03.630 SERIAL » [ACK] (0x06) 09:30:03.631 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 2 09:30:03.637 SERIAL » 0x010900130c022502257e97 (11 bytes) 09:30:03.638 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 126 └─[BinarySwitchCCGet] 09:30:03.638 CNTRLR « [Node 009] parameter #31 has value: 2 09:30:03.639 CNTRLR » [Node 009] querying parameter #32 value... 09:30:03.650 SERIAL « [ACK] (0x06) 09:30:03.651 SERIAL « 0x0104011301e8 (6 bytes) 09:30:03.652 SERIAL » [ACK] (0x06) 09:30:03.654 DRIVER « [RES] [SendData] was sent: true 09:30:03.708 SERIAL « 0x010700137e00000693 (9 bytes) 09:30:03.733 SERIAL » [ACK] (0x06) 09:30:03.733 DRIVER « [REQ] [SendData] callback id: 126 transmit status: OK 09:30:03.761 SERIAL « 0x01090004000c032503ff24 (11 bytes) 09:30:03.762 CNTRLR [Node 012] [~] [Binary Switch] currentValue: "unknown" => true [Endpoint 0] 09:30:03.763 SERIAL » [ACK] (0x06) 09:30:03.764 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: true 09:30:03.769 SERIAL » 0x010a00130d03320100257f81 (12 bytes) 09:30:03.769 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 127 └─[MeterCCGet] duration: kWh 09:30:03.770 CNTRLR « [Node 012] received Binary Switch state: current value: true 09:30:03.771 CNTRLR [Node 012] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 09:30:03.815 SERIAL « [ACK] (0x06) 09:30:03.820 SERIAL « 0x0104011301e8 (6 bytes) 09:30:03.821 SERIAL » [ACK] (0x06) 09:30:03.822 DRIVER « [RES] [SendData] was sent: true 09:30:03.827 CNTRLR [Node 012] MultilevelSwitchCC: doing a partial interview... 09:30:03.827 CNTRLR » [Node 012] requesting current switch state... 09:30:03.868 SERIAL « 0x010700137f0000099d (9 bytes) 09:30:03.868 SERIAL » [ACK] (0x06) 09:30:03.869 DRIVER « [REQ] [SendData] callback id: 127 transmit status: OK 09:30:03.919 SERIAL « 0x01100004000d0a32022144000000cf000076 (18 bytes) 09:30:03.920 CNTRLR [Node 013] [~] [Meter] value[65537]: 2.07 => 2.07 [Endpoint 0] 09:30:03.921 CNTRLR [Node 013] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 09:30:03.921 SERIAL » [ACK] (0x06) 09:30:03.922 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 2.07 time delta: 0 seconds 09:30:03.928 SERIAL » 0x010a00130e0332010025807d (12 bytes) 09:30:03.929 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 128 └─[MeterCCGet] duration: kWh 09:30:03.929 CNTRLR » [Node 013] querying meter value (type = Electric, scale = W)... 09:30:03.934 SERIAL « [ACK] (0x06) 09:30:03.938 SERIAL « 0x0104011301e8 (6 bytes) 09:30:03.938 SERIAL » [ACK] (0x06) 09:30:03.939 DRIVER « [RES] [SendData] was sent: true 09:30:04.006 SERIAL « 0x01070013800000076c (9 bytes) 09:30:04.007 SERIAL » [ACK] (0x06) 09:30:04.008 DRIVER « [REQ] [SendData] callback id: 128 transmit status: OK 09:30:04.019 SERIAL « 0x01100004000e0a320221440000013000008b (18 bytes) 09:30:04.020 CNTRLR [Node 014] [~] [Meter] value[65537]: 3.04 => 3.04 [Endpoint 0] 09:30:04.023 CNTRLR [Node 014] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 09:30:04.024 SERIAL » [ACK] (0x06) 09:30:04.025 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 3.04 time delta: 0 seconds 09:30:04.030 SERIAL » 0x010a00130f0332011025816d (12 bytes) 09:30:04.030 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 129 └─[MeterCCGet] duration: W 09:30:04.031 CNTRLR » [Node 014] querying meter value (type = Electric, scale = W)... 09:30:04.035 SERIAL « [ACK] (0x06) 09:30:04.039 SERIAL « 0x0104011301e8 (6 bytes) 09:30:04.039 SERIAL » [ACK] (0x06) 09:30:04.040 DRIVER « [RES] [SendData] was sent: true 09:30:04.056 SERIAL « 0x010700138100000268 (9 bytes) 09:30:04.056 SERIAL » [ACK] (0x06) 09:30:04.056 DRIVER « [REQ] [SendData] callback id: 129 transmit status: OK 09:30:04.067 SERIAL « 0x010e0004000f083202213200000000d1 (16 bytes) 09:30:04.068 CNTRLR [Node 015] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 09:30:04.069 CNTRLR [Node 015] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 09:30:04.069 SERIAL » [ACK] (0x06) 09:30:04.071 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 09:30:04.074 SERIAL » 0x0109001310022502258277 (11 bytes) 09:30:04.074 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 130 └─[BinarySwitchCCGet] 09:30:04.075 CNTRLR [Node 015] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 09:30:04.103 SERIAL « [ACK] (0x06) 09:30:04.113 SERIAL « 0x0104011301e8 (6 bytes) 09:30:04.114 SERIAL » [ACK] (0x06) 09:30:04.115 DRIVER « [RES] [SendData] was sent: true 09:30:04.118 CNTRLR [Node 015] ConfigurationCC: Loading configuration parameters from device confi g 09:30:04.127 CNTRLR [Node 015] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:30:04.128 CNTRLR [Node 015] [Configuration] 1: metadata updated 09:30:04.130 CNTRLR [Node 015] [Configuration] 16: metadata updated 09:30:04.131 CNTRLR [Node 015] [Configuration] 34: metadata updated 09:30:04.133 CNTRLR [Node 015] [Configuration] 35: metadata updated 09:30:04.134 CNTRLR [Node 015] [Configuration] 39: metadata updated 09:30:04.136 CNTRLR [Node 015] [Configuration] 40: metadata updated 09:30:04.137 CNTRLR [Node 015] [Configuration] 42: metadata updated 09:30:04.139 CNTRLR [Node 015] [Configuration] 43: metadata updated 09:30:04.140 CNTRLR [Node 015] [Configuration] 45: metadata updated 09:30:04.142 CNTRLR [Node 015] [Configuration] 47: metadata updated 09:30:04.143 CNTRLR [Node 015] [Configuration] 49: metadata updated 09:30:04.145 CNTRLR [Node 015] [Configuration] 50: metadata updated 09:30:04.146 CNTRLR [Node 015] [Configuration] 51: metadata updated 09:30:04.148 CNTRLR [Node 015] [Configuration] 52: metadata updated 09:30:04.150 CNTRLR [Node 015] [Configuration] 60: metadata updated 09:30:04.151 CNTRLR [Node 015] [Configuration] 61: metadata updated 09:30:04.153 CNTRLR [Node 015] [Configuration] 62: metadata updated 09:30:04.155 CNTRLR [Node 015] [Configuration] 63: metadata updated 09:30:04.156 CNTRLR [Node 015] [Configuration] 70: metadata updated 09:30:04.158 CNTRLR [Node 015] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:30:04.158 CNTRLR » [Node 015] querying parameter #1 value... 09:30:04.165 SERIAL « 0x01070013820000056c (9 bytes) 09:30:04.165 SERIAL » [ACK] (0x06) 09:30:04.171 DRIVER « [REQ] [SendData] callback id: 130 transmit status: OK 09:30:04.226 SERIAL « 0x010900040010032503ff38 (11 bytes) 09:30:04.227 CNTRLR [Node 016] [~] [Binary Switch] currentValue: "unknown" => true [Endpoint 0] 09:30:04.229 SERIAL » [ACK] (0x06) 09:30:04.240 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: true 09:30:04.247 SERIAL » 0x010900130602984025839f (11 bytes) 09:30:04.247 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 131 └─[SecurityCCNonceGet] 09:30:04.248 CNTRLR « [Node 016] received Binary Switch state: current value: true 09:30:04.248 CNTRLR [Node 016] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 09:30:04.249 CNTRLR [Node 016] MultilevelSwitchCC: doing a partial interview... 09:30:04.249 CNTRLR » [Node 016] requesting current switch state... 09:30:04.255 SERIAL « [ACK] (0x06) 09:30:04.256 SERIAL « 0x0104011301e8 (6 bytes) 09:30:04.257 SERIAL » [ACK] (0x06) 09:30:04.258 DRIVER « [RES] [SendData] was sent: true 09:30:05.626 SERIAL « 0x010700138300008ae2 (9 bytes) 09:30:05.627 SERIAL » [ACK] (0x06) 09:30:05.628 DRIVER « [REQ] [SendData] callback id: 131 transmit status: OK 09:30:05.708 SERIAL « 0x0110000400060a988023c96a1119084e0736 (18 bytes) 09:30:05.709 SERIAL » [ACK] (0x06) 09:30:05.710 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x23c96a1119084e07 09:30:05.717 SERIAL » 0x011e0013061798816ffb93cfc158e9f3cb2db10523ef6387b8e7590769258402 (32 bytes) 09:30:05.718 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 132 └─[SecurityCCCommandEncapsulation] │ nonce id: 35 └─[MultiChannelCCCapabilityGet] endpoint: 2 09:30:05.721 SERIAL « [ACK] (0x06) 09:30:05.728 SERIAL « 0x0104011301e8 (6 bytes) 09:30:05.729 SERIAL » [ACK] (0x06) 09:30:05.730 DRIVER « [RES] [SendData] was sent: true 09:30:05.848 SERIAL « 0x010700138400000c63 (9 bytes) 09:30:05.848 SERIAL » [ACK] (0x06) 09:30:05.849 DRIVER « [REQ] [SendData] callback id: 132 transmit status: OK 09:30:05.934 SERIAL « 0x0108000400060298402f (10 bytes) 09:30:05.934 SERIAL » [ACK] (0x06) 09:30:05.936 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:30:05.946 SERIAL » 0x01110013060a98800187691743129fc3240038 (19 bytes) 09:30:05.947 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x0187691743129fc3 09:30:05.950 SERIAL « [ACK] (0x06) 09:30:05.958 SERIAL « 0x0104011301e8 (6 bytes) 09:30:05.958 SERIAL » [ACK] (0x06) 09:30:05.959 DRIVER « [RES] [SendData] was sent: true 09:30:06.167 SERIAL « 0x0123000400061d98819fc6a3c15ad040f2c1959d191b9e4096bc7801a97cb4695 (37 bytes) a38eae7f8 09:30:06.169 SERIAL » [ACK] (0x06) 09:30:06.173 CNTRLR [Node 006] [~] [Multi Channel] commandClasses: 94,152, [Endpoint 2] [internal] 159,34 => 94,152,159,34 09:30:06.174 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 09:30:06.182 SERIAL » 0x010a00130903700520258519 (12 bytes) 09:30:06.183 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 133 └─[ConfigurationCCGet] parameter #: 32 09:30:06.183 CNTRLR « [Node 006] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 09:30:06.185 CNTRLR [Node 006] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:30:06.238 SERIAL « [ACK] (0x06) 09:30:06.244 SERIAL « 0x0104011301e8 (6 bytes) 09:30:06.244 SERIAL » [ACK] (0x06) 09:30:06.252 DRIVER « [RES] [SendData] was sent: true 09:30:06.257 CNTRLR [Node 006] BatteryCC: doing a partial interview... 09:30:06.257 CNTRLR » [Node 006] querying battery status... 09:30:06.261 SERIAL « 0x010700138500000769 (9 bytes) 09:30:06.262 SERIAL » [ACK] (0x06) 09:30:06.264 DRIVER « [REQ] [SendData] callback id: 133 transmit status: OK 09:30:06.268 SERIAL « 0x010b00040009057006200103a8 (13 bytes) 09:30:06.276 CNTRLR [Node 009] [~] [Configuration] 32: 3 => 3 09:30:06.278 SERIAL » [ACK] (0x06) 09:30:06.294 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 1 value: 3 09:30:06.299 SERIAL » 0x010900130c02260225866c (11 bytes) 09:30:06.299 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 134 └─[MultilevelSwitchCCGet] 09:30:06.300 CNTRLR « [Node 009] parameter #32 has value: 3 09:30:06.300 CNTRLR » [Node 009] querying parameter #33 value... 09:30:06.305 SERIAL « [ACK] (0x06) 09:30:06.307 SERIAL « 0x0104011301e8 (6 bytes) 09:30:06.308 SERIAL » [ACK] (0x06) 09:30:06.309 DRIVER « [RES] [SendData] was sent: true 09:30:06.369 SERIAL « 0x01070013860000066b (9 bytes) 09:30:06.369 SERIAL » [ACK] (0x06) 09:30:06.370 DRIVER « [REQ] [SendData] callback id: 134 transmit status: OK 09:30:06.440 SERIAL « 0x01090004000c03260363bb (11 bytes) 09:30:06.441 CNTRLR [Node 012] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 0] 09:30:06.442 SERIAL » [ACK] (0x06) 09:30:06.444 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 99 09:30:06.447 SERIAL » 0x010a00130d03320110258769 (12 bytes) 09:30:06.447 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 135 └─[MeterCCGet] duration: W 09:30:06.448 CNTRLR [Node 012] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 09:30:06.449 CNTRLR [Node 012] MultilevelSensorCC: doing a partial interview... 09:30:06.449 CNTRLR » [Node 012] querying current sensor reading... 09:30:06.453 SERIAL « [ACK] (0x06) 09:30:06.456 SERIAL « 0x0104011301e8 (6 bytes) 09:30:06.456 SERIAL » [ACK] (0x06) 09:30:06.457 DRIVER « [RES] [SendData] was sent: true 09:30:06.528 SERIAL « 0x01070013870000076b (9 bytes) 09:30:06.528 SERIAL » [ACK] (0x06) 09:30:06.529 DRIVER « [REQ] [SendData] callback id: 135 transmit status: OK 09:30:06.578 SERIAL « 0x010e0004000d083202213200000000d3 (16 bytes) 09:30:06.579 CNTRLR [Node 013] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 09:30:06.580 CNTRLR [Node 013] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 09:30:06.583 SERIAL » [ACK] (0x06) 09:30:06.585 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 09:30:06.589 SERIAL » 0x010a00130e03320110258865 (12 bytes) 09:30:06.589 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 136 └─[MeterCCGet] duration: W 09:30:06.590 CNTRLR [Node 013] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 09:30:06.591 CNTRLR [Node 013] ConfigurationCC: Loading configuration parameters from device confi g 09:30:06.597 CNTRLR [Node 013] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:30:06.597 CNTRLR [Node 013] [Configuration] 3: metadata updated 09:30:06.599 CNTRLR [Node 013] [Configuration] 10: metadata updated 09:30:06.600 CNTRLR [Node 013] [Configuration] 12: metadata updated 09:30:06.601 CNTRLR [Node 013] [Configuration] 13: metadata updated 09:30:06.602 CNTRLR [Node 013] [Configuration] 14: metadata updated 09:30:06.603 CNTRLR [Node 013] [Configuration] 17: metadata updated 09:30:06.604 CNTRLR [Node 013] [Configuration] 18: metadata updated 09:30:06.606 CNTRLR [Node 013] [Configuration] 22: metadata updated 09:30:06.607 CNTRLR [Node 013] [Configuration] 29: metadata updated 09:30:06.608 CNTRLR [Node 013] [Configuration] 30: metadata updated 09:30:06.609 CNTRLR [Node 013] [Configuration] 31: metadata updated 09:30:06.610 CNTRLR [Node 013] [Configuration] 32: metadata updated 09:30:06.611 CNTRLR [Node 013] [Configuration] 33: metadata updated 09:30:06.613 CNTRLR [Node 013] [Configuration] 35: metadata updated 09:30:06.614 CNTRLR [Node 013] [Configuration] 40: metadata updated 09:30:06.615 CNTRLR [Node 013] [Configuration] 42: metadata updated 09:30:06.616 CNTRLR [Node 013] [Configuration] 43: metadata updated 09:30:06.617 CNTRLR [Node 013] [Configuration] 44: metadata updated 09:30:06.618 CNTRLR [Node 013] [Configuration] 50: metadata updated 09:30:06.619 CNTRLR [Node 013] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:30:06.620 CNTRLR » [Node 013] querying parameter #3 value... 09:30:06.651 SERIAL « [ACK] (0x06) 09:30:06.652 SERIAL « 0x0104011301e8 (6 bytes) 09:30:06.653 SERIAL » [ACK] (0x06) 09:30:06.656 DRIVER « [RES] [SendData] was sent: true 09:30:06.668 SERIAL « 0x010700138800000764 (9 bytes) 09:30:06.669 SERIAL » [ACK] (0x06) 09:30:06.670 DRIVER « [REQ] [SendData] callback id: 136 transmit status: OK 09:30:06.679 SERIAL « 0x010e0004000e083202213200000000d0 (16 bytes) 09:30:06.680 CNTRLR [Node 014] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 09:30:06.681 CNTRLR [Node 014] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 09:30:06.682 SERIAL » [ACK] (0x06) 09:30:06.684 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 09:30:06.692 SERIAL » 0x010a00130f03700501258932 (12 bytes) 09:30:06.693 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 137 └─[ConfigurationCCGet] parameter #: 1 09:30:06.694 CNTRLR [Node 014] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 09:30:06.695 CNTRLR [Node 014] ConfigurationCC: Loading configuration parameters from device confi g 09:30:06.702 CNTRLR [Node 014] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:30:06.703 CNTRLR [Node 014] [Configuration] 3: metadata updated 09:30:06.704 CNTRLR [Node 014] [Configuration] 10: metadata updated 09:30:06.706 CNTRLR [Node 014] [Configuration] 12: metadata updated 09:30:06.708 CNTRLR [Node 014] [Configuration] 13: metadata updated 09:30:06.710 CNTRLR [Node 014] [Configuration] 14: metadata updated 09:30:06.711 CNTRLR [Node 014] [Configuration] 17: metadata updated 09:30:06.713 CNTRLR [Node 014] [Configuration] 18: metadata updated 09:30:06.714 CNTRLR [Node 014] [Configuration] 22: metadata updated 09:30:06.716 CNTRLR [Node 014] [Configuration] 29: metadata updated 09:30:06.717 CNTRLR [Node 014] [Configuration] 30: metadata updated 09:30:06.719 CNTRLR [Node 014] [Configuration] 31: metadata updated 09:30:06.720 CNTRLR [Node 014] [Configuration] 32: metadata updated 09:30:06.722 CNTRLR [Node 014] [Configuration] 33: metadata updated 09:30:06.723 CNTRLR [Node 014] [Configuration] 35: metadata updated 09:30:06.725 CNTRLR [Node 014] [Configuration] 40: metadata updated 09:30:06.727 CNTRLR [Node 014] [Configuration] 42: metadata updated 09:30:06.728 CNTRLR [Node 014] [Configuration] 43: metadata updated 09:30:06.730 CNTRLR [Node 014] [Configuration] 44: metadata updated 09:30:06.732 CNTRLR [Node 014] [Configuration] 50: metadata updated 09:30:06.733 CNTRLR [Node 014] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:30:06.734 CNTRLR » [Node 014] querying parameter #3 value... 09:30:06.750 SERIAL « [ACK] (0x06) 09:30:06.751 SERIAL « 0x0104011301e8 (6 bytes) 09:30:06.752 SERIAL » [ACK] (0x06) 09:30:06.759 DRIVER « [RES] [SendData] was sent: true 09:30:06.766 SERIAL « 0x010700138900000260 (9 bytes) 09:30:06.767 SERIAL » [ACK] (0x06) 09:30:06.770 DRIVER « [REQ] [SendData] callback id: 137 transmit status: OK 09:30:06.779 SERIAL « 0x010b0004000f0570060101018d (13 bytes) 09:30:06.785 CNTRLR [Node 015] [~] [Configuration] 1: 1 => 1 09:30:06.786 SERIAL » [ACK] (0x06) 09:30:06.789 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 1 09:30:06.796 SERIAL » 0x0109001310022602258a7c (11 bytes) 09:30:06.796 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 138 └─[MultilevelSwitchCCGet] 09:30:06.797 CNTRLR « [Node 015] parameter #1 has value: 1 09:30:06.797 CNTRLR » [Node 015] querying parameter #16 value... 09:30:06.808 SERIAL « [ACK] (0x06) 09:30:06.809 SERIAL « 0x0104011301e8 (6 bytes) 09:30:06.810 SERIAL » [ACK] (0x06) 09:30:06.812 DRIVER « [RES] [SendData] was sent: true 09:30:06.842 SERIAL « 0x010700138a00000564 (9 bytes) 09:30:06.843 SERIAL » [ACK] (0x06) 09:30:06.843 DRIVER « [REQ] [SendData] callback id: 138 transmit status: OK 09:30:06.892 SERIAL « 0x01090004001003260363a7 (11 bytes) 09:30:06.893 CNTRLR [Node 016] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 0] 09:30:06.894 SERIAL » [ACK] (0x06) 09:30:06.895 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 99 09:30:06.900 SERIAL » 0x0109001306029840258b97 (11 bytes) 09:30:06.901 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 139 └─[SecurityCCNonceGet] 09:30:06.901 CNTRLR [Node 016] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 09:30:06.902 CNTRLR [Node 016] MultilevelSensorCC: doing a partial interview... 09:30:06.902 CNTRLR » [Node 016] querying current sensor reading... 09:30:06.907 SERIAL « [ACK] (0x06) 09:30:06.910 SERIAL « 0x0104011301e8 (6 bytes) 09:30:06.910 SERIAL » [ACK] (0x06) 09:30:06.911 DRIVER « [RES] [SendData] was sent: true 09:30:08.330 SERIAL « 0x010700138b00008eee (9 bytes) 09:30:08.331 SERIAL » [ACK] (0x06) 09:30:08.333 DRIVER « [REQ] [SendData] callback id: 139 transmit status: OK 09:30:08.415 SERIAL « 0x0110000400060a9880b161948c896e9e723c (18 bytes) 09:30:08.415 SERIAL » [ACK] (0x06) 09:30:08.416 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xb161948c896e9e72 09:30:08.420 SERIAL » 0x011d001306169881315b350a898db4dc5564e3b1980803325de27f19258c73 (31 bytes) 09:30:08.420 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 140 └─[SecurityCCCommandEncapsulation] │ nonce id: 177 └─[BatteryCCGet] 09:30:08.423 SERIAL « [ACK] (0x06) 09:30:08.430 SERIAL « 0x0104011301e8 (6 bytes) 09:30:08.430 SERIAL » [ACK] (0x06) 09:30:08.431 DRIVER « [RES] [SendData] was sent: true 09:30:08.556 SERIAL « 0x010700138c00000d6a (9 bytes) 09:30:08.556 SERIAL » [ACK] (0x06) 09:30:08.557 DRIVER « [REQ] [SendData] callback id: 140 transmit status: OK 09:30:08.657 SERIAL « 0x0108000400060298402f (10 bytes) 09:30:08.657 SERIAL » [ACK] (0x06) 09:30:08.658 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:30:08.664 SERIAL » 0x01110013060a988086ff3081a2faae8a240079 (19 bytes) 09:30:08.664 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x86ff3081a2faae8a 09:30:08.667 SERIAL « [ACK] (0x06) 09:30:08.673 SERIAL « 0x0104011301e8 (6 bytes) 09:30:08.674 SERIAL » [ACK] (0x06) 09:30:08.674 DRIVER « [RES] [SendData] was sent: true 09:30:08.882 SERIAL « 0x011d000400061798818887237dd78ee4d7c5af797c86cb4d840abfb95895ff (31 bytes) 09:30:08.883 SERIAL » [ACK] (0x06) 09:30:08.884 CNTRLR [Node 006] [~] [Battery] level: 89 => 89 [Endpoint 0] 09:30:08.885 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 0] 09:30:08.885 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[BatteryCCReport] level: 89 is low: false 09:30:08.889 SERIAL » 0x010a00130903700521258d10 (12 bytes) 09:30:08.889 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 141 └─[ConfigurationCCGet] parameter #: 33 09:30:08.890 CNTRLR « [Node 006] received response for battery information: level: 89 09:30:08.890 CNTRLR [Node 006] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:30:08.922 SERIAL « [ACK] (0x06) 09:30:08.923 SERIAL « 0x0104011301e8 (6 bytes) 09:30:08.923 SERIAL » [ACK] (0x06) 09:30:08.925 DRIVER « [RES] [SendData] was sent: true 09:30:08.931 CNTRLR [Node 006] ZWavePlusCC: doing a partial interview... [Endpoint 1] 09:30:08.931 CNTRLR [Node 006] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 09:30:08.932 CNTRLR [Node 006] ThermostatModeCC: doing a partial interview... [Endpoint 1] 09:30:08.932 CNTRLR » [Node 006] querying current thermostat mode... [Endpoint 1] 09:30:08.966 SERIAL « 0x010700138d00000761 (9 bytes) 09:30:08.967 SERIAL » [ACK] (0x06) 09:30:08.968 DRIVER « [REQ] [SendData] callback id: 141 transmit status: OK 09:30:08.977 SERIAL « 0x010b00040009057006210101ab (13 bytes) 09:30:08.983 CNTRLR [Node 009] [~] [Configuration] 33: 1 => 1 09:30:08.984 SERIAL » [ACK] (0x06) 09:30:08.985 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 1 value: 1 09:30:08.990 SERIAL » 0x010900130c023104258e75 (11 bytes) 09:30:08.990 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 142 └─[MultilevelSensorCCGet] 09:30:08.991 CNTRLR « [Node 009] parameter #33 has value: 1 09:30:08.991 CNTRLR » [Node 009] querying parameter #39 value... 09:30:08.995 SERIAL « [ACK] (0x06) 09:30:08.998 SERIAL « 0x0104011301e8 (6 bytes) 09:30:08.999 SERIAL » [ACK] (0x06) 09:30:08.999 DRIVER « [RES] [SendData] was sent: true 09:30:09.060 SERIAL « 0x010700138e00000663 (9 bytes) 09:30:09.061 SERIAL » [ACK] (0x06) 09:30:09.062 DRIVER « [REQ] [SendData] callback id: 142 transmit status: OK 09:30:09.123 SERIAL « 0x010c0004000c06310504220000ef (14 bytes) 09:30:09.125 CNTRLR [Node 012] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:30:09.126 CNTRLR [Node 012] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 09:30:09.127 SERIAL » [ACK] (0x06) 09:30:09.128 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 09:30:09.134 SERIAL » 0x010a00130d03700503258f34 (12 bytes) 09:30:09.134 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 143 └─[ConfigurationCCGet] parameter #: 3 09:30:09.135 CNTRLR « [Node 012] received current sensor reading: sensor type: Power value: 0 W 09:30:09.136 CNTRLR [Node 012] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 09:30:09.136 CNTRLR [Node 012] MeterCC: doing a partial interview... 09:30:09.137 CNTRLR » [Node 012] querying meter value (type = Electric, scale = kWh)... 09:30:09.142 SERIAL « [ACK] (0x06) 09:30:09.144 SERIAL « 0x0104011301e8 (6 bytes) 09:30:09.144 SERIAL » [ACK] (0x06) 09:30:09.145 DRIVER « [RES] [SendData] was sent: true 09:30:09.218 SERIAL « 0x010700138f0000086c (9 bytes) 09:30:09.218 SERIAL » [ACK] (0x06) 09:30:09.219 DRIVER « [REQ] [SendData] callback id: 143 transmit status: OK 09:30:09.265 SERIAL « 0x010b0004000d0570060301008c (13 bytes) 09:30:09.271 CNTRLR [Node 013] [~] [Configuration] 3: 0 => 0 09:30:09.272 SERIAL » [ACK] (0x06) 09:30:09.274 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 09:30:09.280 SERIAL » 0x010a00130e03700503259028 (12 bytes) 09:30:09.281 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 144 └─[ConfigurationCCGet] parameter #: 3 09:30:09.281 CNTRLR « [Node 013] parameter #3 has value: 0 09:30:09.282 CNTRLR » [Node 013] querying parameter #10 value... 09:30:09.287 SERIAL « [ACK] (0x06) 09:30:09.289 SERIAL « 0x0104011301e8 (6 bytes) 09:30:09.289 SERIAL » [ACK] (0x06) 09:30:09.290 DRIVER « [RES] [SendData] was sent: true 09:30:09.346 SERIAL « 0x01070013900000067d (9 bytes) 09:30:09.347 SERIAL » [ACK] (0x06) 09:30:09.347 DRIVER « [REQ] [SendData] callback id: 144 transmit status: OK 09:30:09.357 SERIAL « 0x010b0004000e0570060301008f (13 bytes) 09:30:09.363 CNTRLR [Node 014] [~] [Configuration] 3: 0 => 0 09:30:09.363 SERIAL » [ACK] (0x06) 09:30:09.364 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 09:30:09.368 SERIAL » 0x010a00130f0370051025913b (12 bytes) 09:30:09.368 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 145 └─[ConfigurationCCGet] parameter #: 16 09:30:09.368 CNTRLR « [Node 014] parameter #3 has value: 0 09:30:09.369 CNTRLR » [Node 014] querying parameter #10 value... 09:30:09.374 SERIAL « [ACK] (0x06) 09:30:09.377 SERIAL « 0x0104011301e8 (6 bytes) 09:30:09.378 SERIAL » [ACK] (0x06) 09:30:09.379 DRIVER « [RES] [SendData] was sent: true 09:30:09.393 SERIAL « 0x010700139100000278 (9 bytes) 09:30:09.393 SERIAL » [ACK] (0x06) 09:30:09.394 DRIVER « [REQ] [SendData] callback id: 145 transmit status: OK 09:30:09.404 SERIAL « 0x010b0004000f0570061001019c (13 bytes) 09:30:09.410 CNTRLR [Node 015] [~] [Configuration] 16: 1 => 1 09:30:09.411 SERIAL » [ACK] (0x06) 09:30:09.412 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 1 09:30:09.417 SERIAL » 0x0109001310023104259275 (11 bytes) 09:30:09.417 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 146 └─[MultilevelSensorCCGet] 09:30:09.418 CNTRLR « [Node 015] parameter #16 has value: 1 09:30:09.418 CNTRLR » [Node 015] querying parameter #34 value... 09:30:09.421 SERIAL « [ACK] (0x06) 09:30:09.425 SERIAL « 0x0104011301e8 (6 bytes) 09:30:09.426 SERIAL » [ACK] (0x06) 09:30:09.427 DRIVER « [RES] [SendData] was sent: true 09:30:09.464 SERIAL « 0x01070013920000047d (9 bytes) 09:30:09.464 SERIAL » [ACK] (0x06) 09:30:09.465 DRIVER « [REQ] [SendData] callback id: 146 transmit status: OK 09:30:09.513 SERIAL « 0x010c0004001006310504220000f3 (14 bytes) 09:30:09.514 CNTRLR [Node 016] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:30:09.514 CNTRLR [Node 016] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 09:30:09.515 SERIAL » [ACK] (0x06) 09:30:09.516 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 09:30:09.527 SERIAL » 0x010900130602984025938f (11 bytes) 09:30:09.527 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 147 └─[SecurityCCNonceGet] 09:30:09.528 CNTRLR « [Node 016] received current sensor reading: sensor type: Power value: 0 W 09:30:09.528 CNTRLR [Node 016] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 09:30:09.556 SERIAL « [ACK] (0x06) 09:30:09.558 SERIAL « 0x0104011301e8 (6 bytes) 09:30:09.558 SERIAL » [ACK] (0x06) 09:30:09.560 DRIVER « [RES] [SendData] was sent: true 09:30:09.637 SERIAL « 0x010700139300000a72 (9 bytes) 09:30:09.638 SERIAL » [ACK] (0x06) 09:30:09.638 DRIVER « [REQ] [SendData] callback id: 147 transmit status: OK 09:30:09.725 SERIAL « 0x0110000400060a98808ab51e458dc845b52e (18 bytes) 09:30:09.725 SERIAL » [ACK] (0x06) 09:30:09.726 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x8ab51e458dc845b5 09:30:09.730 SERIAL » 0x01210013061a988120c3929045efcd162a54dc69fd5b798a30dee60bc9f3f7d92 (35 bytes) 59460 09:30:09.730 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 148 └─[SecurityCCCommandEncapsulation] │ nonce id: 138 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:30:09.733 SERIAL « [ACK] (0x06) 09:30:09.740 SERIAL « 0x0104011301e8 (6 bytes) 09:30:09.741 SERIAL » [ACK] (0x06) 09:30:09.741 DRIVER « [RES] [SendData] was sent: true 09:30:09.907 SERIAL « 0x01070013940000116e (9 bytes) 09:30:09.907 SERIAL » [ACK] (0x06) 09:30:09.908 DRIVER « [REQ] [SendData] callback id: 148 transmit status: OK 09:30:09.991 SERIAL « 0x0108000400060298402f (10 bytes) 09:30:09.991 SERIAL » [ACK] (0x06) 09:30:09.993 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:30:10.004 SERIAL » 0x01110013060a9880439c09c3b6afdd28240034 (19 bytes) 09:30:10.005 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x439c09c3b6afdd28 09:30:10.008 SERIAL « [ACK] (0x06) 09:30:10.015 SERIAL « 0x0104011301e8 (6 bytes) 09:30:10.016 SERIAL » [ACK] (0x06) 09:30:10.017 DRIVER « [RES] [SendData] was sent: true 09:30:10.214 SERIAL « 0x0121000400061b988154469364ad3307a11e160c87f2533d15439408f6c6bf003 (35 bytes) 985e5 09:30:10.216 SERIAL » [ACK] (0x06) 09:30:10.220 CNTRLR [Node 006] [~] [Thermostat Mode] mode: 0 => 0 [Endpoint 1] 09:30:10.223 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Off 09:30:10.233 SERIAL » 0x010a0013090370052725950e (12 bytes) 09:30:10.234 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 149 └─[ConfigurationCCGet] parameter #: 39 09:30:10.236 CNTRLR « [Node 006] received current thermostat mode: Off [Endpoint 1] 09:30:10.237 CNTRLR [Node 006] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 1] [internal] ue => true 09:30:10.238 CNTRLR [Node 006] ThermostatSetpointCC: doing a partial interview... [Endpoint 1] 09:30:10.239 CNTRLR » [Node 006] querying current value of setpoint Heating... [Endpoint 1] 09:30:10.247 SERIAL « [ACK] (0x06) 09:30:10.251 SERIAL « 0x0104011301e8 (6 bytes) 09:30:10.252 SERIAL » [ACK] (0x06) 09:30:10.253 DRIVER « [RES] [SendData] was sent: true 09:30:10.296 SERIAL « 0x010700139500000678 (9 bytes) 09:30:10.297 SERIAL » [ACK] (0x06) 09:30:10.303 DRIVER « [REQ] [SendData] callback id: 149 transmit status: OK 09:30:10.307 SERIAL « 0x010c0004000906700627020258f1 (14 bytes) 09:30:10.315 CNTRLR [Node 009] [~] [Configuration] 39: 600 => 600 09:30:10.317 SERIAL » [ACK] (0x06) 09:30:10.318 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 39 value size: 2 value: 600 09:30:10.323 SERIAL » 0x010a00130c03320100259669 (12 bytes) 09:30:10.323 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 150 └─[MeterCCGet] duration: kWh 09:30:10.324 CNTRLR « [Node 009] parameter #39 has value: 600 09:30:10.324 CNTRLR » [Node 009] querying parameter #40 value... 09:30:10.329 SERIAL « [ACK] (0x06) 09:30:10.332 SERIAL « 0x0104011301e8 (6 bytes) 09:30:10.335 SERIAL » [ACK] (0x06) 09:30:10.336 DRIVER « [RES] [SendData] was sent: true 09:30:10.395 SERIAL « 0x01070013960000077a (9 bytes) 09:30:10.396 SERIAL » [ACK] (0x06) 09:30:10.397 DRIVER « [REQ] [SendData] callback id: 150 transmit status: OK 09:30:10.452 SERIAL « 0x01100004000c0a32022144000000c9000071 (18 bytes) 09:30:10.454 CNTRLR [Node 012] [~] [Meter] value[65537]: 2.01 => 2.01 [Endpoint 0] 09:30:10.455 CNTRLR [Node 012] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 09:30:10.455 SERIAL » [ACK] (0x06) 09:30:10.458 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 2.01 time delta: 0 seconds 09:30:10.463 SERIAL » 0x010a00130d0370050a259725 (12 bytes) 09:30:10.464 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 151 └─[ConfigurationCCGet] parameter #: 10 09:30:10.464 CNTRLR » [Node 012] querying meter value (type = Electric, scale = W)... 09:30:10.480 SERIAL « [ACK] (0x06) 09:30:10.482 SERIAL « 0x0104011301e8 (6 bytes) 09:30:10.482 SERIAL » [ACK] (0x06) 09:30:10.483 DRIVER « [RES] [SendData] was sent: true 09:30:10.558 SERIAL « 0x010700139700000975 (9 bytes) 09:30:10.558 SERIAL » [ACK] (0x06) 09:30:10.559 DRIVER « [REQ] [SendData] callback id: 151 transmit status: OK 09:30:10.603 SERIAL « 0x010b0004000d0570060a010184 (13 bytes) 09:30:10.614 CNTRLR [Node 013] [~] [Configuration] 10: 1 => 1 09:30:10.615 SERIAL » [ACK] (0x06) 09:30:10.617 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 1 09:30:10.630 SERIAL » 0x010a00130e0370050a259829 (12 bytes) 09:30:10.631 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 152 └─[ConfigurationCCGet] parameter #: 10 09:30:10.631 CNTRLR « [Node 013] parameter #10 has value: 1 09:30:10.632 CNTRLR » [Node 013] querying parameter #12 value... 09:30:10.637 SERIAL « [ACK] (0x06) 09:30:10.640 SERIAL « 0x0104011301e8 (6 bytes) 09:30:10.641 SERIAL » [ACK] (0x06) 09:30:10.642 DRIVER « [RES] [SendData] was sent: true 09:30:10.697 SERIAL « 0x010700139800000675 (9 bytes) 09:30:10.697 SERIAL » [ACK] (0x06) 09:30:10.698 DRIVER « [REQ] [SendData] callback id: 152 transmit status: OK 09:30:10.707 SERIAL « 0x010b0004000e0570060a010187 (13 bytes) 09:30:10.712 CNTRLR [Node 014] [~] [Configuration] 10: 1 => 1 09:30:10.713 SERIAL » [ACK] (0x06) 09:30:10.714 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 1 09:30:10.719 SERIAL » 0x010a00130f03700522259901 (12 bytes) 09:30:10.719 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 153 └─[ConfigurationCCGet] parameter #: 34 09:30:10.719 CNTRLR « [Node 014] parameter #10 has value: 1 09:30:10.720 CNTRLR » [Node 014] querying parameter #12 value... 09:30:10.724 SERIAL « [ACK] (0x06) 09:30:10.730 SERIAL « 0x0104011301e8 (6 bytes) 09:30:10.730 SERIAL » [ACK] (0x06) 09:30:10.732 DRIVER « [RES] [SendData] was sent: true 09:30:10.744 SERIAL « 0x010700139900000270 (9 bytes) 09:30:10.745 SERIAL » [ACK] (0x06) 09:30:10.745 DRIVER « [REQ] [SendData] callback id: 153 transmit status: OK 09:30:10.755 SERIAL « 0x010b0004000f05700622013f90 (13 bytes) 09:30:10.760 CNTRLR [Node 015] [~] [Configuration] 34: 63 => 63 09:30:10.761 SERIAL » [ACK] (0x06) 09:30:10.762 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 34 value size: 1 value: 63 09:30:10.767 SERIAL » 0x0109001306029840259a86 (11 bytes) 09:30:10.767 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 154 └─[SecurityCCNonceGet] 09:30:10.767 CNTRLR « [Node 015] parameter #34 has value: 63 09:30:10.768 CNTRLR » [Node 015] querying parameter #35 value... 09:30:10.771 SERIAL « [ACK] (0x06) 09:30:10.777 SERIAL « 0x0104011301e8 (6 bytes) 09:30:10.777 SERIAL » [ACK] (0x06) 09:30:10.778 DRIVER « [RES] [SendData] was sent: true 09:30:10.833 SERIAL « 0x010700139a00000776 (9 bytes) 09:30:10.833 SERIAL » [ACK] (0x06) 09:30:10.834 DRIVER « [REQ] [SendData] callback id: 154 transmit status: OK 09:30:10.915 SERIAL « 0x0110000400060a98809848dabee4271c41d5 (18 bytes) 09:30:10.915 SERIAL » [ACK] (0x06) 09:30:10.916 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x9848dabee4271c41 09:30:10.923 SERIAL » 0x01220013061b98819ff230c664548e9cb9e8ba4e0833e15798b90830738b818ed (36 bytes) b259bd0 09:30:10.924 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 155 └─[SecurityCCCommandEncapsulation] │ nonce id: 152 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:30:10.927 SERIAL « [ACK] (0x06) 09:30:10.934 SERIAL « 0x0104011301e8 (6 bytes) 09:30:10.934 SERIAL » [ACK] (0x06) 09:30:10.935 DRIVER « [RES] [SendData] was sent: true 09:30:11.059 SERIAL « 0x010700139b00000d7d (9 bytes) 09:30:11.059 SERIAL » [ACK] (0x06) 09:30:11.059 DRIVER « [REQ] [SendData] callback id: 155 transmit status: OK 09:30:11.141 SERIAL « 0x0108000400060298402f (10 bytes) 09:30:11.141 SERIAL » [ACK] (0x06) 09:30:11.142 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:30:11.147 SERIAL » 0x01110013060a9880719a083e32a68e0c240006 (19 bytes) 09:30:11.147 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x719a083e32a68e0c 09:30:11.149 SERIAL « [ACK] (0x06) 09:30:11.156 SERIAL « 0x0104011301e8 (6 bytes) 09:30:11.156 SERIAL » [ACK] (0x06) 09:30:11.156 DRIVER « [RES] [SendData] was sent: true 09:30:11.265 CNTRLR [Node 016] MeterCC: doing a partial interview... 09:30:11.266 CNTRLR » [Node 016] querying meter value (type = Electric, scale = kWh)... 09:30:11.365 SERIAL « 0x0124000400061e9881c19df691f9cfae563db64db87069d9b12da4ab71e2d6220 (38 bytes) dc85035b372 09:30:11.366 SERIAL » [ACK] (0x06) 09:30:11.368 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 1] 09:30:11.369 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 09:30:11.370 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 09:30:11.373 SERIAL » 0x010a00130903700528259c08 (12 bytes) 09:30:11.373 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 156 └─[ConfigurationCCGet] parameter #: 40 09:30:11.374 CNTRLR « [Node 006] received current value of setpoint Heating: 10 °C [Endpoint 1] 09:30:11.375 CNTRLR [Node 006] [~] [Thermostat Setpoint] interviewComplete [Endpoint 1] [internal] : true => true 09:30:11.375 CNTRLR [Node 006] NotificationCC: doing a partial interview... [Endpoint 1] 09:30:11.376 CNTRLR » [Node 006] querying notification status for Power Management... [Endpoint 1] 09:30:11.381 SERIAL « [ACK] (0x06) 09:30:11.382 SERIAL « 0x0104011301e8 (6 bytes) 09:30:11.383 SERIAL » [ACK] (0x06) 09:30:11.384 DRIVER « [RES] [SendData] was sent: true 09:30:11.457 SERIAL « 0x010700139c0000087f (9 bytes) 09:30:11.457 SERIAL » [ACK] (0x06) 09:30:11.458 DRIVER « [REQ] [SendData] callback id: 156 transmit status: OK 09:30:11.467 SERIAL « 0x010b00040009057006280103a0 (13 bytes) 09:30:11.477 CNTRLR [Node 009] [~] [Configuration] 40: 3 => 3 09:30:11.479 SERIAL » [ACK] (0x06) 09:30:11.481 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 3 09:30:11.491 SERIAL » 0x010a00130c03320110259d72 (12 bytes) 09:30:11.492 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 157 └─[MeterCCGet] duration: W 09:30:11.493 CNTRLR « [Node 009] parameter #40 has value: 3 09:30:11.493 CNTRLR » [Node 009] querying parameter #41 value... 09:30:11.500 SERIAL « [ACK] (0x06) 09:30:11.502 SERIAL « 0x0104011301e8 (6 bytes) 09:30:11.504 SERIAL » [ACK] (0x06) 09:30:11.505 DRIVER « [RES] [SendData] was sent: true 09:30:11.563 SERIAL « 0x010700139d00000771 (9 bytes) 09:30:11.563 SERIAL » [ACK] (0x06) 09:30:11.564 DRIVER « [REQ] [SendData] callback id: 157 transmit status: OK 09:30:11.619 SERIAL « 0x010e0004000c083202213200000000d2 (16 bytes) 09:30:11.620 CNTRLR [Node 012] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 09:30:11.621 CNTRLR [Node 012] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 09:30:11.621 SERIAL » [ACK] (0x06) 09:30:11.623 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 09:30:11.626 SERIAL » 0x010a00130d0370050c259e2a (12 bytes) 09:30:11.626 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 158 └─[ConfigurationCCGet] parameter #: 12 09:30:11.627 CNTRLR [Node 012] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 09:30:11.655 SERIAL « [ACK] (0x06) 09:30:11.659 SERIAL « 0x0104011301e8 (6 bytes) 09:30:11.660 SERIAL » [ACK] (0x06) 09:30:11.662 DRIVER « [RES] [SendData] was sent: true 09:30:11.664 CNTRLR [Node 012] ConfigurationCC: Loading configuration parameters from device confi g 09:30:11.670 CNTRLR [Node 012] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:30:11.670 CNTRLR [Node 012] [Configuration] 1: metadata updated 09:30:11.671 CNTRLR [Node 012] [Configuration] 2: metadata updated 09:30:11.672 CNTRLR [Node 012] [Configuration] 3: metadata updated 09:30:11.674 CNTRLR [Node 012] [Configuration] 10: metadata updated 09:30:11.675 CNTRLR [Node 012] [Configuration] 12: metadata updated 09:30:11.676 CNTRLR [Node 012] [Configuration] 13: metadata updated 09:30:11.677 CNTRLR [Node 012] [Configuration] 14: metadata updated 09:30:11.678 CNTRLR [Node 012] [Configuration] 17: metadata updated 09:30:11.679 CNTRLR [Node 012] [Configuration] 18: metadata updated 09:30:11.680 CNTRLR [Node 012] [Configuration] 22: metadata updated 09:30:11.682 CNTRLR [Node 012] [Configuration] 29: metadata updated 09:30:11.683 CNTRLR [Node 012] [Configuration] 30: metadata updated 09:30:11.684 CNTRLR [Node 012] [Configuration] 31: metadata updated 09:30:11.685 CNTRLR [Node 012] [Configuration] 32: metadata updated 09:30:11.694 CNTRLR [Node 012] [Configuration] 33: metadata updated 09:30:11.696 CNTRLR [Node 012] [Configuration] 35: metadata updated 09:30:11.697 CNTRLR [Node 012] [Configuration] 40: metadata updated 09:30:11.698 CNTRLR [Node 012] [Configuration] 42: metadata updated 09:30:11.699 CNTRLR [Node 012] [Configuration] 43: metadata updated 09:30:11.700 CNTRLR [Node 012] [Configuration] 44: metadata updated 09:30:11.701 CNTRLR [Node 012] [Configuration] 50: metadata updated 09:30:11.702 CNTRLR [Node 012] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:30:11.705 CNTRLR » [Node 012] querying parameter #1 value... 09:30:11.728 SERIAL « 0x010700139e00000a7f (9 bytes) 09:30:11.728 SERIAL » [ACK] (0x06) 09:30:11.729 DRIVER « [REQ] [SendData] callback id: 158 transmit status: OK 09:30:11.776 SERIAL « 0x010c0004000d0670060c02009612 (14 bytes) 09:30:11.781 CNTRLR [Node 013] [~] [Configuration] 12: 150 => 150 09:30:11.783 SERIAL » [ACK] (0x06) 09:30:11.784 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 150 09:30:11.787 SERIAL » 0x010a00130e0370050c259f28 (12 bytes) 09:30:11.788 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 159 └─[ConfigurationCCGet] parameter #: 12 09:30:11.788 CNTRLR « [Node 013] parameter #12 has value: 150 09:30:11.788 CNTRLR » [Node 013] querying parameter #13 value... 09:30:11.792 SERIAL « [ACK] (0x06) 09:30:11.796 SERIAL « 0x0104011301e8 (6 bytes) 09:30:11.797 SERIAL » [ACK] (0x06) 09:30:11.797 DRIVER « [RES] [SendData] was sent: true 09:30:11.856 SERIAL « 0x010700139f00000672 (9 bytes) 09:30:11.856 SERIAL » [ACK] (0x06) 09:30:11.857 DRIVER « [REQ] [SendData] callback id: 159 transmit status: OK 09:30:11.867 SERIAL « 0x010c0004000e0670060c02009611 (14 bytes) 09:30:11.872 CNTRLR [Node 014] [~] [Configuration] 12: 150 => 150 09:30:11.874 SERIAL » [ACK] (0x06) 09:30:11.875 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 150 09:30:11.878 SERIAL » 0x010a00130f0370052325a039 (12 bytes) 09:30:11.878 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 160 └─[ConfigurationCCGet] parameter #: 35 09:30:11.879 CNTRLR « [Node 014] parameter #12 has value: 150 09:30:11.879 CNTRLR » [Node 014] querying parameter #13 value... 09:30:11.887 SERIAL « [ACK] (0x06) 09:30:11.889 SERIAL « 0x0104011301e8 (6 bytes) 09:30:11.889 SERIAL » [ACK] (0x06) 09:30:11.890 DRIVER « [RES] [SendData] was sent: true 09:30:11.904 SERIAL « 0x01070013a000000249 (9 bytes) 09:30:11.904 SERIAL » [ACK] (0x06) 09:30:11.904 DRIVER « [REQ] [SendData] callback id: 160 transmit status: OK 09:30:11.914 SERIAL « 0x010b0004000f057006230100ae (13 bytes) 09:30:11.919 CNTRLR [Node 015] [~] [Configuration] 35: 0 => 0 09:30:11.920 SERIAL » [ACK] (0x06) 09:30:11.921 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 0 09:30:11.924 SERIAL » 0x010a0013100332010025a142 (12 bytes) 09:30:11.925 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 161 └─[MeterCCGet] duration: kWh 09:30:11.925 CNTRLR « [Node 015] parameter #35 has value: 0 09:30:11.926 CNTRLR » [Node 015] querying parameter #39 value... 09:30:11.929 SERIAL « [ACK] (0x06) 09:30:11.936 SERIAL « 0x0104011301e8 (6 bytes) 09:30:11.936 SERIAL » [ACK] (0x06) 09:30:11.938 DRIVER « [RES] [SendData] was sent: true 09:30:11.971 SERIAL « 0x01070013a10000054f (9 bytes) 09:30:11.972 SERIAL » [ACK] (0x06) 09:30:11.972 DRIVER « [REQ] [SendData] callback id: 161 transmit status: OK 09:30:12.021 SERIAL « 0x0110000400100a320221440000014c0000e9 (18 bytes) 09:30:12.022 CNTRLR [Node 016] [~] [Meter] value[65537]: 3.32 => 3.32 [Endpoint 0] 09:30:12.023 CNTRLR [Node 016] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 09:30:12.023 SERIAL » [ACK] (0x06) 09:30:12.025 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 3.32 time delta: 0 seconds 09:30:12.044 SERIAL » 0x010900130602984025a2be (11 bytes) 09:30:12.045 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 162 └─[SecurityCCNonceGet] 09:30:12.045 CNTRLR » [Node 016] querying meter value (type = Electric, scale = W)... 09:30:12.049 SERIAL « [ACK] (0x06) 09:30:12.053 SERIAL « 0x0104011301e8 (6 bytes) 09:30:12.054 SERIAL » [ACK] (0x06) 09:30:12.054 DRIVER « [RES] [SendData] was sent: true 09:30:12.147 SERIAL « 0x01070013a200000a43 (9 bytes) 09:30:12.148 SERIAL » [ACK] (0x06) 09:30:12.148 DRIVER « [REQ] [SendData] callback id: 162 transmit status: OK 09:30:12.235 SERIAL « 0x0110000400060a98808bf7fc18e971cebb8a (18 bytes) 09:30:12.235 SERIAL » [ACK] (0x06) 09:30:12.237 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x8bf7fc18e971cebb 09:30:12.243 SERIAL » 0x01240013061d9881b42c3962e9695c669bad945c7a74067d762f8b833ce882546 (38 bytes) 9f27d25a30b 09:30:12.244 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 163 └─[SecurityCCCommandEncapsulation] │ nonce id: 139 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: Power Management 09:30:12.247 SERIAL « [ACK] (0x06) 09:30:12.255 SERIAL « 0x0104011301e8 (6 bytes) 09:30:12.255 SERIAL » [ACK] (0x06) 09:30:12.256 DRIVER « [RES] [SendData] was sent: true 09:30:12.372 SERIAL « 0x01070013a300000d45 (9 bytes) 09:30:12.372 SERIAL » [ACK] (0x06) 09:30:12.373 DRIVER « [REQ] [SendData] callback id: 163 transmit status: OK 09:30:12.451 SERIAL « 0x0108000400060298402f (10 bytes) 09:30:12.452 SERIAL » [ACK] (0x06) 09:30:12.453 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:30:12.463 SERIAL » 0x01110013060a9880766115bc3fd4da52240010 (19 bytes) 09:30:12.464 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x766115bc3fd4da52 09:30:12.467 SERIAL « [ACK] (0x06) 09:30:12.473 SERIAL « 0x0104011301e8 (6 bytes) 09:30:12.474 SERIAL » [ACK] (0x06) 09:30:12.475 DRIVER « [RES] [SendData] was sent: true 09:30:12.687 SERIAL « 0x012700040006219881fa40209ea4a16a26aa400651c033e34fceff981dd7ee764 (41 bytes) 379d8dc848c5a35ef 09:30:12.688 SERIAL » [ACK] (0x06) 09:30:12.692 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 09:30:12.699 SERIAL » 0x010a0013090370052925a431 (12 bytes) 09:30:12.700 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 164 └─[ConfigurationCCGet] parameter #: 41 09:30:12.701 CNTRLR [Node 006] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 1] 54 09:30:12.703 CNTRLR » [Node 006] querying notification status for System... [Endpoint 1] 09:30:12.711 SERIAL « [ACK] (0x06) 09:30:12.714 SERIAL « 0x0104011301e8 (6 bytes) 09:30:12.714 SERIAL » [ACK] (0x06) 09:30:12.716 DRIVER « [RES] [SendData] was sent: true 09:30:12.776 SERIAL « 0x01070013a400000748 (9 bytes) 09:30:12.778 SERIAL » [ACK] (0x06) 09:30:12.781 DRIVER « [REQ] [SendData] callback id: 164 transmit status: OK 09:30:12.788 SERIAL « 0x010b00040009057006290102a0 (13 bytes) 09:30:12.795 CNTRLR [Node 009] [~] [Configuration] 41: 2 => 2 09:30:12.797 SERIAL » [ACK] (0x06) 09:30:12.799 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 41 value size: 1 value: 2 09:30:12.805 SERIAL » 0x010a00130c0370050125a51d (12 bytes) 09:30:12.807 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 165 └─[ConfigurationCCGet] parameter #: 1 09:30:12.808 CNTRLR « [Node 009] parameter #41 has value: 2 09:30:12.808 CNTRLR » [Node 009] querying parameter #42 value... 09:30:12.812 SERIAL « [ACK] (0x06) 09:30:12.818 SERIAL « 0x0104011301e8 (6 bytes) 09:30:12.819 SERIAL » [ACK] (0x06) 09:30:12.819 DRIVER « [RES] [SendData] was sent: true 09:30:12.878 SERIAL « 0x01070013a500000648 (9 bytes) 09:30:12.879 SERIAL » [ACK] (0x06) 09:30:12.879 DRIVER « [REQ] [SendData] callback id: 165 transmit status: OK 09:30:14.483 CNTRLR [Node 012] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:30:14.986 SERIAL » 0x010a00130c0370050125a51d (12 bytes) 09:30:14.986 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 165 └─[ConfigurationCCGet] parameter #: 1 09:30:14.988 SERIAL « [ACK] (0x06) 09:30:14.994 SERIAL « 0x0104011301e8 (6 bytes) 09:30:14.995 SERIAL » [ACK] (0x06) 09:30:14.995 DRIVER « [RES] [SendData] was sent: true 09:30:15.057 SERIAL « 0x01070013a500000749 (9 bytes) 09:30:15.057 SERIAL » [ACK] (0x06) 09:30:15.058 DRIVER « [REQ] [SendData] callback id: 165 transmit status: OK 09:30:16.660 CNTRLR [Node 012] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:30:17.167 SERIAL » 0x010a00130c0370050125a51d (12 bytes) 09:30:17.168 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 165 └─[ConfigurationCCGet] parameter #: 1 09:30:17.170 SERIAL « [ACK] (0x06) 09:30:17.176 SERIAL « 0x0104011301e8 (6 bytes) 09:30:17.177 SERIAL » [ACK] (0x06) 09:30:17.178 DRIVER « [RES] [SendData] was sent: true 09:30:17.239 SERIAL « 0x01070013a500000648 (9 bytes) 09:30:17.239 SERIAL » [ACK] (0x06) 09:30:17.240 DRIVER « [REQ] [SendData] callback id: 165 transmit status: OK 09:30:18.851 SERIAL » 0x010a00130d0370050d25a613 (12 bytes) 09:30:18.852 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 166 └─[ConfigurationCCGet] parameter #: 13 09:30:18.853 CNTRLR « [Node 012] received no value for parameter #1 09:30:18.854 CNTRLR » [Node 012] querying parameter #2 value... 09:30:18.860 SERIAL « [ACK] (0x06) 09:30:18.862 SERIAL « 0x0104011301e8 (6 bytes) 09:30:18.863 SERIAL » [ACK] (0x06) 09:30:18.864 DRIVER « [RES] [SendData] was sent: true 09:30:18.899 SERIAL « 0x01070013a600000449 (9 bytes) 09:30:18.900 SERIAL » [ACK] (0x06) 09:30:18.901 DRIVER « [REQ] [SendData] callback id: 166 transmit status: OK 09:30:18.948 SERIAL « 0x010b0004000d0570060d010183 (13 bytes) 09:30:18.968 CNTRLR [Node 013] [~] [Configuration] 13: 1 => 1 09:30:18.970 SERIAL » [ACK] (0x06) 09:30:18.974 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 1 09:30:18.980 SERIAL » 0x010a00130e0370050d25a711 (12 bytes) 09:30:18.981 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 167 └─[ConfigurationCCGet] parameter #: 13 09:30:18.981 CNTRLR « [Node 013] parameter #13 has value: 1 09:30:18.982 CNTRLR » [Node 013] querying parameter #14 value... 09:30:18.988 SERIAL « [ACK] (0x06) 09:30:18.991 SERIAL « 0x0104011301e8 (6 bytes) 09:30:18.991 SERIAL » [ACK] (0x06) 09:30:18.995 DRIVER « [RES] [SendData] was sent: true 09:30:19.037 SERIAL « 0x01070013a700000549 (9 bytes) 09:30:19.037 SERIAL » [ACK] (0x06) 09:30:19.038 DRIVER « [REQ] [SendData] callback id: 167 transmit status: OK 09:30:19.047 SERIAL « 0x010b0004000e0570060d010180 (13 bytes) 09:30:19.052 CNTRLR [Node 014] [~] [Configuration] 13: 1 => 1 09:30:19.053 SERIAL » [ACK] (0x06) 09:30:19.054 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 1 09:30:19.057 SERIAL » 0x010a00130f0370052725a835 (12 bytes) 09:30:19.057 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 168 └─[ConfigurationCCGet] parameter #: 39 09:30:19.058 CNTRLR « [Node 014] parameter #13 has value: 1 09:30:19.058 CNTRLR » [Node 014] querying parameter #14 value... 09:30:19.062 SERIAL « [ACK] (0x06) 09:30:19.067 SERIAL « 0x0104011301e8 (6 bytes) 09:30:19.067 SERIAL » [ACK] (0x06) 09:30:19.068 DRIVER « [RES] [SendData] was sent: true 09:30:19.083 SERIAL « 0x01070013a800000241 (9 bytes) 09:30:19.083 SERIAL » [ACK] (0x06) 09:30:19.083 DRIVER « [REQ] [SendData] callback id: 168 transmit status: OK 09:30:19.094 SERIAL « 0x010c0004000f06700627020258f7 (14 bytes) 09:30:19.099 CNTRLR [Node 015] [~] [Configuration] 39: 600 => 600 09:30:19.100 SERIAL » [ACK] (0x06) 09:30:19.101 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 39 value size: 2 value: 600 09:30:19.104 SERIAL » 0x010a0013100332011025a95a (12 bytes) 09:30:19.104 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 169 └─[MeterCCGet] duration: W 09:30:19.105 CNTRLR « [Node 015] parameter #39 has value: 600 09:30:19.105 CNTRLR » [Node 015] querying parameter #40 value... 09:30:19.108 SERIAL « [ACK] (0x06) 09:30:19.113 SERIAL « 0x0104011301e8 (6 bytes) 09:30:19.114 SERIAL » [ACK] (0x06) 09:30:19.114 DRIVER « [RES] [SendData] was sent: true 09:30:19.151 SERIAL « 0x01070013a900000547 (9 bytes) 09:30:19.151 SERIAL » [ACK] (0x06) 09:30:19.152 DRIVER « [REQ] [SendData] callback id: 169 transmit status: OK 09:30:19.201 SERIAL « 0x010e00040010083202213200000000ce (16 bytes) 09:30:19.202 CNTRLR [Node 016] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 09:30:19.203 CNTRLR [Node 016] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 09:30:19.203 SERIAL » [ACK] (0x06) 09:30:19.204 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 09:30:19.209 SERIAL » 0x010900130602984025aab6 (11 bytes) 09:30:19.209 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 170 └─[SecurityCCNonceGet] 09:30:19.210 CNTRLR [Node 016] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 09:30:19.237 SERIAL « [ACK] (0x06) 09:30:19.240 SERIAL « 0x0104011301e8 (6 bytes) 09:30:19.241 SERIAL » [ACK] (0x06) 09:30:19.242 DRIVER « [RES] [SendData] was sent: true 09:30:19.244 CNTRLR [Node 016] ConfigurationCC: Loading configuration parameters from device confi g 09:30:19.250 CNTRLR [Node 016] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:30:19.250 CNTRLR [Node 016] [Configuration] 1: metadata updated 09:30:19.251 CNTRLR [Node 016] [Configuration] 2: metadata updated 09:30:19.253 CNTRLR [Node 016] [Configuration] 3: metadata updated 09:30:19.254 CNTRLR [Node 016] [Configuration] 10: metadata updated 09:30:19.255 CNTRLR [Node 016] [Configuration] 12: metadata updated 09:30:19.256 CNTRLR [Node 016] [Configuration] 13: metadata updated 09:30:19.257 CNTRLR [Node 016] [Configuration] 14: metadata updated 09:30:19.258 CNTRLR [Node 016] [Configuration] 17: metadata updated 09:30:19.260 CNTRLR [Node 016] [Configuration] 18: metadata updated 09:30:19.261 CNTRLR [Node 016] [Configuration] 22: metadata updated 09:30:19.262 CNTRLR [Node 016] [Configuration] 29: metadata updated 09:30:19.264 CNTRLR [Node 016] [Configuration] 30: metadata updated 09:30:19.265 CNTRLR [Node 016] [Configuration] 31: metadata updated 09:30:19.267 CNTRLR [Node 016] [Configuration] 32: metadata updated 09:30:19.269 CNTRLR [Node 016] [Configuration] 33: metadata updated 09:30:19.270 CNTRLR [Node 016] [Configuration] 35: metadata updated 09:30:19.271 CNTRLR [Node 016] [Configuration] 40: metadata updated 09:30:19.272 CNTRLR [Node 016] [Configuration] 42: metadata updated 09:30:19.273 CNTRLR [Node 016] [Configuration] 43: metadata updated 09:30:19.274 CNTRLR [Node 016] [Configuration] 44: metadata updated 09:30:19.275 CNTRLR [Node 016] [Configuration] 50: metadata updated 09:30:19.277 CNTRLR [Node 016] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:30:19.278 CNTRLR » [Node 016] querying parameter #1 value... 09:30:20.640 SERIAL « 0x01070013aa00008ecf (9 bytes) 09:30:20.641 SERIAL » [ACK] (0x06) 09:30:20.642 DRIVER « [REQ] [SendData] callback id: 170 transmit status: OK 09:30:20.727 SERIAL « 0x0110000400060a9880c2bd0cff030e3ca9eb (18 bytes) 09:30:20.728 SERIAL » [ACK] (0x06) 09:30:20.729 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xc2bd0cff030e3ca9 09:30:20.736 SERIAL » 0x01240013061d988104e9f6e3640c318aa57247b8afbecd2c09fbc2c0dc7d6b415 (38 bytes) 6370f25aba2 09:30:20.737 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 171 └─[SecurityCCCommandEncapsulation] │ nonce id: 194 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: System 09:30:20.741 SERIAL « [ACK] (0x06) 09:30:20.748 SERIAL « 0x0104011301e8 (6 bytes) 09:30:20.749 SERIAL » [ACK] (0x06) 09:30:20.750 DRIVER « [RES] [SendData] was sent: true 09:30:20.861 SERIAL « 0x01070013ab00000c4c (9 bytes) 09:30:20.861 SERIAL » [ACK] (0x06) 09:30:20.862 DRIVER « [REQ] [SendData] callback id: 171 transmit status: OK 09:30:20.947 SERIAL « 0x0108000400060298402f (10 bytes) 09:30:20.948 SERIAL » [ACK] (0x06) 09:30:20.948 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:30:20.953 SERIAL » 0x01110013060a98803dc8ab250c34544124009b (19 bytes) 09:30:20.953 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x3dc8ab250c345441 09:30:20.955 SERIAL « [ACK] (0x06) 09:30:20.962 SERIAL « 0x0104011301e8 (6 bytes) 09:30:20.962 SERIAL » [ACK] (0x06) 09:30:20.963 DRIVER « [RES] [SendData] was sent: true 09:30:21.183 SERIAL « 0x0127000400062198818e621832504862b301e2a2ff0b6e47bc2bc89a3b2a073d0 (41 bytes) b8fb993027dae8464 09:30:21.184 SERIAL » [ACK] (0x06) 09:30:21.186 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: System notification status: 255 notification event: Unknown (0xfe) 09:30:21.189 SERIAL » 0x010a0013090370052a25ac3a (12 bytes) 09:30:21.189 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 172 └─[ConfigurationCCGet] parameter #: 42 09:30:21.190 CNTRLR [Node 006] [~] [Notification] System[unknown]: 254 => 254 [Endpoint 1] 09:30:21.192 CNTRLR [Node 006] [~] [Notification] interviewComplete: true [Endpoint 1] [internal] => true 09:30:21.227 SERIAL « [ACK] (0x06) 09:30:21.230 SERIAL « 0x0104011301e8 (6 bytes) 09:30:21.231 SERIAL » [ACK] (0x06) 09:30:21.232 DRIVER « [RES] [SendData] was sent: true 09:30:21.234 CNTRLR [Node 006] ProtectionCC: doing a partial interview... 09:30:21.234 CNTRLR » [Node 006] querying protection status... 09:30:21.266 SERIAL « 0x01070013ac00000740 (9 bytes) 09:30:21.267 SERIAL » [ACK] (0x06) 09:30:21.268 DRIVER « [REQ] [SendData] callback id: 172 transmit status: OK 09:30:21.275 SERIAL « 0x010b000400090570062a0103a2 (13 bytes) 09:30:21.281 CNTRLR [Node 009] [~] [Configuration] 42: 3 => 3 09:30:21.282 SERIAL » [ACK] (0x06) 09:30:21.283 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 3 09:30:21.286 SERIAL » 0x010a00130c0370050225ad16 (12 bytes) 09:30:21.286 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 173 └─[ConfigurationCCGet] parameter #: 2 09:30:21.287 CNTRLR « [Node 009] parameter #42 has value: 3 09:30:21.287 CNTRLR » [Node 009] querying parameter #43 value... 09:30:21.290 SERIAL « [ACK] (0x06) 09:30:21.296 SERIAL « 0x0104011301e8 (6 bytes) 09:30:21.297 SERIAL » [ACK] (0x06) 09:30:21.297 DRIVER « [RES] [SendData] was sent: true 09:30:21.357 SERIAL « 0x01070013ad00000741 (9 bytes) 09:30:21.358 SERIAL » [ACK] (0x06) 09:30:21.358 DRIVER « [REQ] [SendData] callback id: 173 transmit status: OK 09:30:22.985 CNTRLR [Node 012] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:30:23.489 SERIAL » 0x010a00130c0370050225ad16 (12 bytes) 09:30:23.490 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 173 └─[ConfigurationCCGet] parameter #: 2 09:30:23.492 SERIAL « [ACK] (0x06) 09:30:23.498 SERIAL « 0x0104011301e8 (6 bytes) 09:30:23.499 SERIAL » [ACK] (0x06) 09:30:23.500 DRIVER « [RES] [SendData] was sent: true 09:30:23.561 SERIAL « 0x01070013ad00000741 (9 bytes) 09:30:23.561 SERIAL » [ACK] (0x06) 09:30:23.562 DRIVER « [REQ] [SendData] callback id: 173 transmit status: OK 09:30:25.166 CNTRLR [Node 012] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:30:25.672 SERIAL » 0x010a00130c0370050225ad16 (12 bytes) 09:30:25.673 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 173 └─[ConfigurationCCGet] parameter #: 2 09:30:25.675 SERIAL « [ACK] (0x06) 09:30:25.682 SERIAL « 0x0104011301e8 (6 bytes) 09:30:25.682 SERIAL » [ACK] (0x06) 09:30:25.683 DRIVER « [RES] [SendData] was sent: true 09:30:25.744 SERIAL « 0x01070013ad00000741 (9 bytes) 09:30:25.745 SERIAL » [ACK] (0x06) 09:30:25.746 DRIVER « [REQ] [SendData] callback id: 173 transmit status: OK 09:30:27.365 SERIAL » 0x010a00130d0370050e25ae18 (12 bytes) 09:30:27.366 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 174 └─[ConfigurationCCGet] parameter #: 14 09:30:27.367 CNTRLR « [Node 012] received no value for parameter #2 09:30:27.368 CNTRLR » [Node 012] querying parameter #3 value... 09:30:27.374 SERIAL « [ACK] (0x06) 09:30:27.377 SERIAL « 0x0104011301e8 (6 bytes) 09:30:27.377 SERIAL » [ACK] (0x06) 09:30:27.379 DRIVER « [RES] [SendData] was sent: true 09:30:27.413 SERIAL « 0x01070013ae00000540 (9 bytes) 09:30:27.414 SERIAL » [ACK] (0x06) 09:30:27.415 DRIVER « [REQ] [SendData] callback id: 174 transmit status: OK 09:30:27.461 SERIAL « 0x010b0004000d0570060e010081 (13 bytes) 09:30:27.469 CNTRLR [Node 013] [~] [Configuration] 14: 0 => 0 09:30:27.471 SERIAL » [ACK] (0x06) 09:30:27.485 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 0 09:30:27.489 SERIAL » 0x010a00130e0370050e25af1a (12 bytes) 09:30:27.490 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 175 └─[ConfigurationCCGet] parameter #: 14 09:30:27.490 CNTRLR « [Node 013] parameter #14 has value: 0 09:30:27.491 CNTRLR » [Node 013] querying parameter #17 value... 09:30:27.499 SERIAL « [ACK] (0x06) 09:30:27.501 SERIAL « 0x0104011301e8 (6 bytes) 09:30:27.502 SERIAL » [ACK] (0x06) 09:30:27.505 DRIVER « [RES] [SendData] was sent: true 09:30:27.546 SERIAL « 0x01070013af00000541 (9 bytes) 09:30:27.547 SERIAL » [ACK] (0x06) 09:30:27.547 DRIVER « [REQ] [SendData] callback id: 175 transmit status: OK 09:30:27.557 SERIAL « 0x010b0004000e0570060e010082 (13 bytes) 09:30:27.565 CNTRLR [Node 014] [~] [Configuration] 14: 0 => 0 09:30:27.566 SERIAL » [ACK] (0x06) 09:30:27.567 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 0 09:30:27.571 SERIAL » 0x010a00130f0370052825b022 (12 bytes) 09:30:27.572 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 176 └─[ConfigurationCCGet] parameter #: 40 09:30:27.576 CNTRLR « [Node 014] parameter #14 has value: 0 09:30:27.576 CNTRLR » [Node 014] querying parameter #17 value... 09:30:27.582 SERIAL « [ACK] (0x06) 09:30:27.589 SERIAL « 0x0104011301e8 (6 bytes) 09:30:27.589 SERIAL » [ACK] (0x06) 09:30:27.592 DRIVER « [RES] [SendData] was sent: true 09:30:27.604 SERIAL « 0x01070013b000000259 (9 bytes) 09:30:27.605 SERIAL » [ACK] (0x06) 09:30:27.606 DRIVER « [REQ] [SendData] callback id: 176 transmit status: OK 09:30:27.615 SERIAL « 0x010b0004000f057006280150f5 (13 bytes) 09:30:27.623 CNTRLR [Node 015] [~] [Configuration] 40: 80 => 80 09:30:27.624 SERIAL » [ACK] (0x06) 09:30:27.630 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 80 09:30:27.636 SERIAL » 0x010a0013100370050125b115 (12 bytes) 09:30:27.637 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 177 └─[ConfigurationCCGet] parameter #: 1 09:30:27.638 CNTRLR « [Node 015] parameter #40 has value: 80 09:30:27.638 CNTRLR » [Node 015] querying parameter #42 value... 09:30:27.643 SERIAL « [ACK] (0x06) 09:30:27.645 SERIAL « 0x0104011301e8 (6 bytes) 09:30:27.648 SERIAL » [ACK] (0x06) 09:30:27.649 DRIVER « [RES] [SendData] was sent: true 09:30:27.684 SERIAL « 0x01070013b10000045e (9 bytes) 09:30:27.684 SERIAL » [ACK] (0x06) 09:30:27.685 DRIVER « [REQ] [SendData] callback id: 177 transmit status: OK 09:30:29.289 CNTRLR [Node 016] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:30:29.800 SERIAL » 0x010a0013100370050125b115 (12 bytes) 09:30:29.802 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 177 └─[ConfigurationCCGet] parameter #: 1 09:30:29.805 SERIAL « [ACK] (0x06) 09:30:29.811 SERIAL « 0x0104011301e8 (6 bytes) 09:30:29.813 SERIAL » [ACK] (0x06) 09:30:29.814 DRIVER « [RES] [SendData] was sent: true 09:30:29.849 SERIAL « 0x01070013b10000045e (9 bytes) 09:30:29.850 SERIAL » [ACK] (0x06) 09:30:29.851 DRIVER « [REQ] [SendData] callback id: 177 transmit status: OK 09:30:31.456 CNTRLR [Node 016] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:30:31.959 SERIAL » 0x010a0013100370050125b115 (12 bytes) 09:30:31.959 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 177 └─[ConfigurationCCGet] parameter #: 1 09:30:31.961 SERIAL « [ACK] (0x06) 09:30:31.967 SERIAL « 0x0104011301e8 (6 bytes) 09:30:31.968 SERIAL » [ACK] (0x06) 09:30:31.968 DRIVER « [RES] [SendData] was sent: true 09:30:32.006 SERIAL « 0x01070013b10000045e (9 bytes) 09:30:32.006 SERIAL » [ACK] (0x06) 09:30:32.007 DRIVER « [REQ] [SendData] callback id: 177 transmit status: OK 09:30:33.614 SERIAL » 0x010900130602984025b2ae (11 bytes) 09:30:33.614 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 178 └─[SecurityCCNonceGet] 09:30:33.614 CNTRLR « [Node 016] received no value for parameter #1 09:30:33.615 CNTRLR » [Node 016] querying parameter #2 value... 09:30:33.617 SERIAL « [ACK] (0x06) 09:30:33.622 SERIAL « 0x0104011301e8 (6 bytes) 09:30:33.622 SERIAL » [ACK] (0x06) 09:30:33.623 DRIVER « [RES] [SendData] was sent: true 09:30:34.992 SERIAL « 0x01070013b200008ad3 (9 bytes) 09:30:34.993 SERIAL » [ACK] (0x06) 09:30:34.994 DRIVER « [REQ] [SendData] callback id: 178 transmit status: OK 09:30:35.081 SERIAL « 0x0110000400060a98808e5a9423fe34bfa54c (18 bytes) 09:30:35.082 SERIAL » [ACK] (0x06) 09:30:35.083 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x8e5a9423fe34bfa5 09:30:35.090 SERIAL » 0x01210013061a98814d5a46beba81c701e0f1e59d4d463e8e3fdda184e84e01372 (35 bytes) 5b3c9 09:30:35.091 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 179 └─[SecurityCCCommandEncapsulation] │ nonce id: 142 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 09:30:35.094 SERIAL « [ACK] (0x06) 09:30:35.102 SERIAL « 0x0104011301e8 (6 bytes) 09:30:35.102 SERIAL » [ACK] (0x06) 09:30:35.103 DRIVER « [RES] [SendData] was sent: true 09:30:35.228 SERIAL « 0x01070013b300000d55 (9 bytes) 09:30:35.229 SERIAL » [ACK] (0x06) 09:30:35.229 DRIVER « [REQ] [SendData] callback id: 179 transmit status: OK 09:30:35.329 SERIAL « 0x0108000400060298402f (10 bytes) 09:30:35.330 SERIAL » [ACK] (0x06) 09:30:35.331 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:30:35.340 SERIAL » 0x01110013060a9880b2bf45ebf84cdde32400e4 (19 bytes) 09:30:35.341 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xb2bf45ebf84cdde3 09:30:35.348 SERIAL « [ACK] (0x06) 09:30:35.349 SERIAL « 0x0104011301e8 (6 bytes) 09:30:35.350 SERIAL » [ACK] (0x06) 09:30:35.351 DRIVER « [RES] [SendData] was sent: true 09:30:35.520 SERIAL « 0x0121000400061b9881d80f4e362c6893e869bdb21aacf9fc3fb26bfcc38395e84 (35 bytes) 221df 09:30:35.521 SERIAL » [ACK] (0x06) 09:30:35.524 CNTRLR [Node 006] [~] [Protection] local: 0 => 0 [Endpoint 1] 09:30:35.527 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ProtectionCCReport] local: Unprotected 09:30:35.533 SERIAL » 0x010a0013090370052b25b423 (12 bytes) 09:30:35.534 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 180 └─[ConfigurationCCGet] parameter #: 43 09:30:35.535 CNTRLR « [Node 006] received protection status: local: Unprotected 09:30:35.536 CNTRLR [Node 006] [~] [Protection] interviewComplete: true => [Endpoint 1] [internal] true 09:30:35.608 SERIAL « [ACK] (0x06) 09:30:35.613 SERIAL « 0x0104011301e8 (6 bytes) 09:30:35.613 SERIAL » [ACK] (0x06) 09:30:35.615 DRIVER « [RES] [SendData] was sent: true 09:30:35.617 CNTRLR [Node 006] BatteryCC: doing a partial interview... [Endpoint 1] 09:30:35.617 CNTRLR » [Node 006] querying battery status... [Endpoint 1] 09:30:35.620 SERIAL « 0x01070013b400000758 (9 bytes) 09:30:35.620 SERIAL » [ACK] (0x06) 09:30:35.621 DRIVER « [REQ] [SendData] callback id: 180 transmit status: OK 09:30:35.623 SERIAL « 0x010b000400090570062b0101a1 (13 bytes) 09:30:35.629 CNTRLR [Node 009] [~] [Configuration] 43: 1 => 1 09:30:35.630 SERIAL » [ACK] (0x06) 09:30:35.631 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 1 09:30:35.634 SERIAL » 0x010a00130c0370050325b50f (12 bytes) 09:30:35.634 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 181 └─[ConfigurationCCGet] parameter #: 3 09:30:35.635 CNTRLR « [Node 009] parameter #43 has value: 1 09:30:35.635 CNTRLR [Node 009] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 09:30:35.635 CNTRLR [Node 009] MultiChannelAssociationCC: doing a partial interview... 09:30:35.636 CNTRLR » [Node 009] querying multi channel association group #1... 09:30:35.639 SERIAL « [ACK] (0x06) 09:30:35.643 SERIAL « 0x0104011301e8 (6 bytes) 09:30:35.643 SERIAL » [ACK] (0x06) 09:30:35.646 DRIVER « [RES] [SendData] was sent: true 09:30:35.711 SERIAL « 0x01070013b500000856 (9 bytes) 09:30:35.711 SERIAL » [ACK] (0x06) 09:30:35.712 DRIVER « [REQ] [SendData] callback id: 181 transmit status: OK 09:30:35.764 SERIAL « 0x010b0004000c0570060301008d (13 bytes) 09:30:35.769 CNTRLR [Node 012] [~] [Configuration] 3: 0 => 0 09:30:35.770 SERIAL » [ACK] (0x06) 09:30:35.771 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 09:30:35.774 SERIAL » 0x010a001309038e020125b6f2 (12 bytes) 09:30:35.775 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 182 └─[MultiChannelAssociationCCGet] group id: 1 09:30:35.775 CNTRLR « [Node 012] parameter #3 has value: 0 09:30:35.776 CNTRLR » [Node 012] querying parameter #10 value... 09:30:35.779 SERIAL « [ACK] (0x06) 09:30:35.784 SERIAL « 0x0104011301e8 (6 bytes) 09:30:35.784 SERIAL » [ACK] (0x06) 09:30:35.785 DRIVER « [RES] [SendData] was sent: true 09:30:35.856 SERIAL « 0x01070013b600000855 (9 bytes) 09:30:35.857 SERIAL » [ACK] (0x06) 09:30:35.857 DRIVER « [REQ] [SendData] callback id: 182 transmit status: OK 09:30:35.867 SERIAL « 0x010b00040009058e0301050075 (13 bytes) 09:30:35.868 SERIAL » [ACK] (0x06) 09:30:35.870 CNTRLR [Node 009] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 09:30:35.871 CNTRLR [Node 009] [~] [Multi Channel Association] nodeIds[1]: => 09:30:35.872 CNTRLR [Node 009] [~] [Multi Channel Association] endpoints[1]: => 09:30:35.874 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: endpoints: 09:30:35.877 SERIAL » 0x010a00130d0370051125b71e (12 bytes) 09:30:35.877 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 183 └─[ConfigurationCCGet] parameter #: 17 09:30:35.878 CNTRLR « [Node 009] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 09:30:35.878 CNTRLR » [Node 009] querying multi channel association group #2... 09:30:35.885 SERIAL « [ACK] (0x06) 09:30:35.887 SERIAL « 0x0104011301e8 (6 bytes) 09:30:35.887 SERIAL » [ACK] (0x06) 09:30:35.887 DRIVER « [RES] [SendData] was sent: true 09:30:35.924 SERIAL « 0x01070013b700000458 (9 bytes) 09:30:35.924 SERIAL » [ACK] (0x06) 09:30:35.925 DRIVER « [REQ] [SendData] callback id: 183 transmit status: OK 09:30:35.972 SERIAL « 0x010b0004000d05700611010a94 (13 bytes) 09:30:35.977 CNTRLR [Node 013] [~] [Configuration] 17: 10 => 10 09:30:35.978 SERIAL » [ACK] (0x06) 09:30:35.979 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 17 value size: 1 value: 10 09:30:35.982 SERIAL » 0x010a001309038e020225b8ff (12 bytes) 09:30:35.982 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 184 └─[MultiChannelAssociationCCGet] group id: 2 09:30:35.983 CNTRLR « [Node 013] parameter #17 has value: 10 09:30:35.983 CNTRLR » [Node 013] querying parameter #18 value... 09:30:35.986 SERIAL « [ACK] (0x06) 09:30:35.992 SERIAL « 0x0104011301e8 (6 bytes) 09:30:35.993 SERIAL » [ACK] (0x06) 09:30:35.993 DRIVER « [RES] [SendData] was sent: true 09:30:36.056 SERIAL « 0x01070013b800000754 (9 bytes) 09:30:36.057 SERIAL » [ACK] (0x06) 09:30:36.057 DRIVER « [REQ] [SendData] callback id: 184 transmit status: OK 09:30:36.067 SERIAL « 0x010b00040009058e0302050076 (13 bytes) 09:30:36.067 SERIAL » [ACK] (0x06) 09:30:36.068 CNTRLR [Node 009] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 09:30:36.069 CNTRLR [Node 009] [~] [Multi Channel Association] nodeIds[2]: => 09:30:36.070 CNTRLR [Node 009] [~] [Multi Channel Association] endpoints[2]: => 09:30:36.071 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 09:30:36.074 SERIAL » 0x010a00130e0370051125b913 (12 bytes) 09:30:36.075 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 185 └─[ConfigurationCCGet] parameter #: 17 09:30:36.075 CNTRLR « [Node 009] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 09:30:36.076 CNTRLR [Node 009] [~] [Association] hasLifeline: true => true [internal] 09:30:36.076 CNTRLR [Node 009] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 09:30:36.105 SERIAL « [ACK] (0x06) 09:30:36.108 SERIAL « 0x0104011301e8 (6 bytes) 09:30:36.108 SERIAL » [ACK] (0x06) 09:30:36.110 DRIVER « [RES] [SendData] was sent: true 09:30:36.115 CNTRLR [Node 009] Interview stage completed: CommandClasses 09:30:36.116 CNTRLR [Node 009] Interview stage completed: OverwriteConfig 09:30:36.116 CNTRLR » [Node 009] requesting node neighbors... 09:30:36.120 SERIAL « 0x01070013b900000250 (9 bytes) 09:30:36.121 SERIAL » [ACK] (0x06) 09:30:36.121 DRIVER « [REQ] [SendData] callback id: 185 transmit status: OK 09:30:36.126 SERIAL « 0x010b0004000e05700611010a97 (13 bytes) 09:30:36.132 CNTRLR [Node 014] [~] [Configuration] 17: 10 => 10 09:30:36.133 SERIAL » [ACK] (0x06) 09:30:36.134 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 17 value size: 1 value: 10 09:30:36.137 SERIAL » 0x010700800900000071 (9 bytes) 09:30:36.138 DRIVER » [Node 009] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:30:36.138 CNTRLR « [Node 014] parameter #17 has value: 10 09:30:36.139 CNTRLR » [Node 014] querying parameter #18 value... 09:30:36.142 SERIAL « [ACK] (0x06) 09:30:36.146 SERIAL « 0x0120018065ee886b0700000000000000000000000000000000000000000000000 (34 bytes) 031 09:30:36.147 SERIAL » [ACK] (0x06) 09:30:36.149 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 10, 11, 12, 14, 15, 16, 20, 24, 25, 26, 28, 30, 31, 33 , 34, 35 09:30:36.153 SERIAL » 0x010a00130f0370052a25ba2a (12 bytes) 09:30:36.153 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 186 └─[ConfigurationCCGet] parameter #: 42 09:30:36.154 CNTRLR « [Node 009] node neighbors received: 1, 3, 6, 7, 10, 11, 12, 14, 15, 16, 20, 24, 25, 26, 28, 30, 31, 33, 34, 35 09:30:36.154 CNTRLR [Node 009] Interview stage completed: Neighbors 09:30:36.154 CNTRLR [Node 009] Interview completed 09:30:36.158 SERIAL « [ACK] (0x06) 09:30:36.161 SERIAL « 0x0104011301e8 (6 bytes) 09:30:36.161 SERIAL » [ACK] (0x06) 09:30:36.162 DRIVER « [RES] [SendData] was sent: true 09:30:36.179 SERIAL « 0x01070013ba00000253 (9 bytes) 09:30:36.179 SERIAL » [ACK] (0x06) 09:30:36.180 DRIVER « [REQ] [SendData] callback id: 186 transmit status: OK 09:30:36.190 SERIAL « 0x010b0004000f0570062a010fa8 (13 bytes) 09:30:36.195 CNTRLR [Node 015] [~] [Configuration] 42: 15 => 15 09:30:36.196 SERIAL » [ACK] (0x06) 09:30:36.196 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 15 09:30:36.200 SERIAL » 0x010a0013100370050225bb1c (12 bytes) 09:30:36.200 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 187 └─[ConfigurationCCGet] parameter #: 2 09:30:36.200 CNTRLR « [Node 015] parameter #42 has value: 15 09:30:36.201 CNTRLR » [Node 015] querying parameter #43 value... 09:30:36.204 SERIAL « [ACK] (0x06) 09:30:36.209 SERIAL « 0x0104011301e8 (6 bytes) 09:30:36.210 SERIAL » [ACK] (0x06) 09:30:36.211 DRIVER « [RES] [SendData] was sent: true 09:30:36.246 SERIAL « 0x01070013bb00000454 (9 bytes) 09:30:36.247 SERIAL » [ACK] (0x06) 09:30:36.247 DRIVER « [REQ] [SendData] callback id: 187 transmit status: OK 09:30:37.850 CNTRLR [Node 016] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:30:38.358 SERIAL » 0x010a0013100370050225bb1c (12 bytes) 09:30:38.359 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 187 └─[ConfigurationCCGet] parameter #: 2 09:30:38.361 SERIAL « [ACK] (0x06) 09:30:38.367 SERIAL « 0x0104011301e8 (6 bytes) 09:30:38.367 SERIAL » [ACK] (0x06) 09:30:38.367 DRIVER « [RES] [SendData] was sent: true 09:30:38.405 SERIAL « 0x01070013bb00000454 (9 bytes) 09:30:38.405 SERIAL » [ACK] (0x06) 09:30:38.406 DRIVER « [REQ] [SendData] callback id: 187 transmit status: OK 09:30:40.009 CNTRLR [Node 016] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:30:40.519 SERIAL » 0x010a0013100370050225bb1c (12 bytes) 09:30:40.520 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 187 └─[ConfigurationCCGet] parameter #: 2 09:30:40.522 SERIAL « [ACK] (0x06) 09:30:40.528 SERIAL « 0x0104011301e8 (6 bytes) 09:30:40.529 SERIAL » [ACK] (0x06) 09:30:40.530 DRIVER « [RES] [SendData] was sent: true 09:30:40.567 SERIAL « 0x01070013bb00000454 (9 bytes) 09:30:40.567 SERIAL » [ACK] (0x06) 09:30:40.568 DRIVER « [REQ] [SendData] callback id: 187 transmit status: OK 09:30:42.177 SERIAL » 0x010900130602984025bca0 (11 bytes) 09:30:42.177 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 188 └─[SecurityCCNonceGet] 09:30:42.178 CNTRLR « [Node 016] received no value for parameter #2 09:30:42.178 CNTRLR » [Node 016] querying parameter #3 value... 09:30:42.181 SERIAL « [ACK] (0x06) 09:30:42.186 SERIAL « 0x0104011301e8 (6 bytes) 09:30:42.186 SERIAL » [ACK] (0x06) 09:30:42.187 DRIVER « [RES] [SendData] was sent: true 09:30:43.521 SERIAL « 0x01070013bc000086d1 (9 bytes) 09:30:43.522 SERIAL » [ACK] (0x06) 09:30:43.523 DRIVER « [REQ] [SendData] callback id: 188 transmit status: OK 09:30:43.610 SERIAL « 0x0110000400060a988021c59c7660eb2c0056 (18 bytes) 09:30:43.611 SERIAL » [ACK] (0x06) 09:30:43.612 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x21c59c7660eb2c00 09:30:43.617 SERIAL » 0x01210013061a9881b6664d5d9dd069e1ae0fe9de22d69e21d912fc4bdbc7f2b92 (35 bytes) 5bda3 09:30:43.617 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 189 └─[SecurityCCCommandEncapsulation] │ nonce id: 33 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BatteryCCGet] 09:30:43.620 SERIAL « [ACK] (0x06) 09:30:43.628 SERIAL « 0x0104011301e8 (6 bytes) 09:30:43.628 SERIAL » [ACK] (0x06) 09:30:43.629 DRIVER « [RES] [SendData] was sent: true 09:30:43.747 SERIAL « 0x01070013bd00000c5a (9 bytes) 09:30:43.747 SERIAL » [ACK] (0x06) 09:30:43.748 DRIVER « [REQ] [SendData] callback id: 189 transmit status: OK 09:30:43.848 SERIAL « 0x0108000400060298402f (10 bytes) 09:30:43.849 SERIAL » [ACK] (0x06) 09:30:43.850 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:30:43.860 SERIAL » 0x01110013060a9880089d16d3d7013d73240005 (19 bytes) 09:30:43.861 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x089d16d3d7013d73 09:30:43.863 SERIAL « [ACK] (0x06) 09:30:43.870 SERIAL « 0x0104011301e8 (6 bytes) 09:30:43.871 SERIAL » [ACK] (0x06) 09:30:43.872 DRIVER « [RES] [SendData] was sent: true 09:30:44.095 SERIAL « 0x0121000400061b9881c136b91c7d0ad2863ff5afc6ef784aa20883012a7db62d7 (35 bytes) 5d494 09:30:44.097 SERIAL » [ACK] (0x06) 09:30:44.099 CNTRLR [Node 006] [~] [Battery] level: 89 => 89 [Endpoint 1] 09:30:44.101 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 1] 09:30:44.102 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BatteryCCReport] level: 89 is low: false 09:30:44.109 SERIAL » 0x010a00130c0370050a25be0d (12 bytes) 09:30:44.110 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 190 └─[ConfigurationCCGet] parameter #: 10 09:30:44.111 CNTRLR « [Node 006] received response for battery information: [Endpoint 1] level: 89 09:30:44.112 CNTRLR [Node 006] [~] [Battery] interviewComplete: true => tr [Endpoint 1] [internal] ue 09:30:44.193 SERIAL « [ACK] (0x06) 09:30:44.197 SERIAL « 0x0104011301e8 (6 bytes) 09:30:44.197 SERIAL » [ACK] (0x06) 09:30:44.198 DRIVER « [RES] [SendData] was sent: true 09:30:44.201 CNTRLR [Node 006] ClockCC: doing a partial interview... 09:30:44.201 CNTRLR » [Node 006] requesting current clock setting... 09:30:44.222 SERIAL « 0x01070013be00000b5e (9 bytes) 09:30:44.222 SERIAL » [ACK] (0x06) 09:30:44.223 DRIVER « [REQ] [SendData] callback id: 190 transmit status: OK 09:30:44.276 SERIAL « 0x010b0004000c0570060a010185 (13 bytes) 09:30:44.281 CNTRLR [Node 012] [~] [Configuration] 10: 1 => 1 09:30:44.282 SERIAL » [ACK] (0x06) 09:30:44.283 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 1 09:30:44.286 SERIAL » 0x010a00130d0370051225bf15 (12 bytes) 09:30:44.287 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 191 └─[ConfigurationCCGet] parameter #: 18 09:30:44.287 CNTRLR « [Node 012] parameter #10 has value: 1 09:30:44.287 CNTRLR » [Node 012] querying parameter #12 value... 09:30:44.293 SERIAL « [ACK] (0x06) 09:30:44.296 SERIAL « 0x0104011301e8 (6 bytes) 09:30:44.297 SERIAL » [ACK] (0x06) 09:30:44.299 DRIVER « [RES] [SendData] was sent: true 09:30:44.388 SERIAL « 0x01070013bf0000095d (9 bytes) 09:30:44.388 SERIAL » [ACK] (0x06) 09:30:44.389 DRIVER « [REQ] [SendData] callback id: 191 transmit status: OK 09:30:44.436 SERIAL « 0x010b0004000d05700612010a97 (13 bytes) 09:30:44.442 CNTRLR [Node 013] [~] [Configuration] 18: 10 => 10 09:30:44.443 SERIAL » [ACK] (0x06) 09:30:44.444 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 18 value size: 1 value: 10 09:30:44.447 SERIAL » 0x010a00130e0370051225c069 (12 bytes) 09:30:44.448 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 192 └─[ConfigurationCCGet] parameter #: 18 09:30:44.448 CNTRLR « [Node 013] parameter #18 has value: 10 09:30:44.448 CNTRLR » [Node 013] querying parameter #22 value... 09:30:44.454 SERIAL « [ACK] (0x06) 09:30:44.460 SERIAL « 0x0104011301e8 (6 bytes) 09:30:44.460 SERIAL » [ACK] (0x06) 09:30:44.462 DRIVER « [RES] [SendData] was sent: true 09:30:44.526 SERIAL « 0x01070013c00000072c (9 bytes) 09:30:44.526 SERIAL » [ACK] (0x06) 09:30:44.527 DRIVER « [REQ] [SendData] callback id: 192 transmit status: OK 09:30:44.537 SERIAL « 0x010b0004000e05700612010a94 (13 bytes) 09:30:44.542 CNTRLR [Node 014] [~] [Configuration] 18: 10 => 10 09:30:44.543 SERIAL » [ACK] (0x06) 09:30:44.544 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 18 value size: 1 value: 10 09:30:44.547 SERIAL » 0x010a00130f0370052b25c150 (12 bytes) 09:30:44.547 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 193 └─[ConfigurationCCGet] parameter #: 43 09:30:44.548 CNTRLR « [Node 014] parameter #18 has value: 10 09:30:44.548 CNTRLR » [Node 014] querying parameter #22 value... 09:30:44.551 SERIAL « [ACK] (0x06) 09:30:44.560 SERIAL « 0x0104011301e8 (6 bytes) 09:30:44.560 SERIAL » [ACK] (0x06) 09:30:44.561 DRIVER « [RES] [SendData] was sent: true 09:30:44.573 SERIAL « 0x01070013c100000228 (9 bytes) 09:30:44.573 SERIAL » [ACK] (0x06) 09:30:44.574 DRIVER « [REQ] [SendData] callback id: 193 transmit status: OK 09:30:44.584 SERIAL « 0x010b0004000f0570062b011eb8 (13 bytes) 09:30:44.591 CNTRLR [Node 015] [~] [Configuration] 43: 30 => 30 09:30:44.592 SERIAL » [ACK] (0x06) 09:30:44.593 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 30 09:30:44.596 SERIAL » 0x010a0013100370050325c264 (12 bytes) 09:30:44.597 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 194 └─[ConfigurationCCGet] parameter #: 3 09:30:44.597 CNTRLR « [Node 015] parameter #43 has value: 30 09:30:44.597 CNTRLR » [Node 015] querying parameter #45 value... 09:30:44.601 SERIAL « [ACK] (0x06) 09:30:44.606 SERIAL « 0x0104011301e8 (6 bytes) 09:30:44.606 SERIAL » [ACK] (0x06) 09:30:44.607 DRIVER « [RES] [SendData] was sent: true 09:30:44.643 SERIAL « 0x01070013c20000052c (9 bytes) 09:30:44.644 SERIAL » [ACK] (0x06) 09:30:44.644 DRIVER « [REQ] [SendData] callback id: 194 transmit status: OK 09:30:44.692 SERIAL « 0x010b0004001005700603010091 (13 bytes) 09:30:44.697 CNTRLR [Node 016] [~] [Configuration] 3: 0 => 0 09:30:44.698 SERIAL » [ACK] (0x06) 09:30:44.699 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 09:30:44.706 SERIAL » 0x010900130602984025c3df (11 bytes) 09:30:44.706 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 195 └─[SecurityCCNonceGet] 09:30:44.707 CNTRLR « [Node 016] parameter #3 has value: 0 09:30:44.707 CNTRLR » [Node 016] querying parameter #10 value... 09:30:44.710 SERIAL « [ACK] (0x06) 09:30:44.714 SERIAL « 0x0104011301e8 (6 bytes) 09:30:44.715 SERIAL » [ACK] (0x06) 09:30:44.716 DRIVER « [RES] [SendData] was sent: true 09:30:44.818 SERIAL « 0x01070013c300000b23 (9 bytes) 09:30:44.818 SERIAL » [ACK] (0x06) 09:30:44.818 DRIVER « [REQ] [SendData] callback id: 195 transmit status: OK 09:30:44.900 SERIAL « 0x0110000400060a988030db9877670a69ae51 (18 bytes) 09:30:44.901 SERIAL » [ACK] (0x06) 09:30:44.902 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x30db9877670a69ae 09:30:44.908 SERIAL » 0x01210013061a98812ca16f0078e45c30fcbb8d446578733095f47f6fbc8461822 (35 bytes) 5c441 09:30:44.909 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 196 └─[SecurityCCCommandEncapsulation] │ nonce id: 48 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ClockCCGet] 09:30:44.912 SERIAL « [ACK] (0x06) 09:30:44.920 SERIAL « 0x0104011301e8 (6 bytes) 09:30:44.920 SERIAL » [ACK] (0x06) 09:30:44.921 DRIVER « [RES] [SendData] was sent: true 09:30:45.048 SERIAL « 0x01070013c400000d22 (9 bytes) 09:30:45.049 SERIAL » [ACK] (0x06) 09:30:45.050 DRIVER « [REQ] [SendData] callback id: 196 transmit status: OK 09:30:45.126 SERIAL « 0x0108000400060298402f (10 bytes) 09:30:45.127 SERIAL » [ACK] (0x06) 09:30:45.128 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:30:45.137 SERIAL » 0x01110013060a98807409b9a668a28abd240052 (19 bytes) 09:30:45.137 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x7409b9a668a28abd 09:30:45.140 SERIAL « [ACK] (0x06) 09:30:45.146 SERIAL « 0x0104011301e8 (6 bytes) 09:30:45.147 SERIAL » [ACK] (0x06) 09:30:45.148 DRIVER « [RES] [SendData] was sent: true 09:30:45.360 SERIAL « 0x0122000400061c9881da8fa3c4c60b7e0158be36351c016cb6b174c97df72aaa2 (36 bytes) 274e9c1 09:30:45.361 SERIAL » [ACK] (0x06) 09:30:45.364 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ClockCCReport] clock setting: Sunday, 09:24 09:30:45.370 SERIAL » 0x010a00130c0370050c25c570 (12 bytes) 09:30:45.370 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 197 └─[ConfigurationCCGet] parameter #: 12 09:30:45.371 CNTRLR « [Node 006] received current clock setting: Sunday, 09:24 09:30:45.372 CNTRLR [Node 006] [~] [Clock] interviewComplete: true => true [Endpoint 1] [internal] 09:30:45.433 SERIAL « [ACK] (0x06) 09:30:45.438 SERIAL « 0x0104011301e8 (6 bytes) 09:30:45.439 SERIAL » [ACK] (0x06) 09:30:45.440 DRIVER « [RES] [SendData] was sent: true 09:30:45.448 CNTRLR [Node 006] ZWavePlusCC: doing a partial interview... [Endpoint 2] 09:30:45.449 CNTRLR [Node 006] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 09:30:45.450 CNTRLR [Node 006] MultilevelSensorCC: doing a partial interview... [Endpoint 2] 09:30:45.450 CNTRLR » [Node 006] querying Air temperature sensor reading... [Endpoint 2] 09:30:45.501 SERIAL « 0x01070013c500000d23 (9 bytes) 09:30:45.502 SERIAL » [ACK] (0x06) 09:30:45.503 DRIVER « [REQ] [SendData] callback id: 197 transmit status: OK 09:30:45.555 SERIAL « 0x010c0004000c0670060c02009613 (14 bytes) 09:30:45.560 CNTRLR [Node 012] [~] [Configuration] 12: 150 => 150 09:30:45.561 SERIAL » [ACK] (0x06) 09:30:45.562 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 150 09:30:45.565 SERIAL » 0x010a00130d0370051625c668 (12 bytes) 09:30:45.566 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 198 └─[ConfigurationCCGet] parameter #: 22 09:30:45.566 CNTRLR « [Node 012] parameter #12 has value: 150 09:30:45.567 CNTRLR » [Node 012] querying parameter #13 value... 09:30:45.570 SERIAL « [ACK] (0x06) 09:30:45.575 SERIAL « 0x0104011301e8 (6 bytes) 09:30:45.576 SERIAL » [ACK] (0x06) 09:30:45.576 DRIVER « [RES] [SendData] was sent: true 09:30:45.626 SERIAL « 0x01070013c600000429 (9 bytes) 09:30:45.626 SERIAL » [ACK] (0x06) 09:30:45.628 DRIVER « [REQ] [SendData] callback id: 198 transmit status: OK 09:30:45.667 SERIAL « 0x010c0004000d067006160200f06e (14 bytes) 09:30:45.672 CNTRLR [Node 013] [~] [Configuration] 22: 240 => 240 09:30:45.674 SERIAL » [ACK] (0x06) 09:30:45.675 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 240 09:30:45.678 SERIAL » 0x010a00130e0370051625c76a (12 bytes) 09:30:45.679 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 199 └─[ConfigurationCCGet] parameter #: 22 09:30:45.679 CNTRLR « [Node 013] parameter #22 has value: 240 09:30:45.680 CNTRLR » [Node 013] querying parameter #29 value... 09:30:45.684 SERIAL « [ACK] (0x06) 09:30:45.688 SERIAL « 0x0104011301e8 (6 bytes) 09:30:45.688 SERIAL » [ACK] (0x06) 09:30:45.690 DRIVER « [RES] [SendData] was sent: true 09:30:45.757 SERIAL « 0x01070013c70000072b (9 bytes) 09:30:45.757 SERIAL » [ACK] (0x06) 09:30:45.758 DRIVER « [REQ] [SendData] callback id: 199 transmit status: OK 09:30:45.767 SERIAL « 0x010c0004000e067006160200f06d (14 bytes) 09:30:45.776 CNTRLR [Node 014] [~] [Configuration] 22: 240 => 240 09:30:45.777 SERIAL » [ACK] (0x06) 09:30:45.778 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 240 09:30:45.781 SERIAL » 0x010a00130f0370052d25c85f (12 bytes) 09:30:45.781 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 200 └─[ConfigurationCCGet] parameter #: 45 09:30:45.781 CNTRLR « [Node 014] parameter #22 has value: 240 09:30:45.782 CNTRLR » [Node 014] querying parameter #29 value... 09:30:45.785 SERIAL « [ACK] (0x06) 09:30:45.789 SERIAL « 0x0104011301e8 (6 bytes) 09:30:45.790 SERIAL » [ACK] (0x06) 09:30:45.790 DRIVER « [RES] [SendData] was sent: true 09:30:45.811 SERIAL « 0x01070013c800000221 (9 bytes) 09:30:45.811 SERIAL » [ACK] (0x06) 09:30:45.812 DRIVER « [REQ] [SendData] callback id: 200 transmit status: OK 09:30:45.817 SERIAL « 0x010b0004000f0570062d010aaa (13 bytes) 09:30:45.822 CNTRLR [Node 015] [~] [Configuration] 45: 10 => 10 09:30:45.823 SERIAL » [ACK] (0x06) 09:30:45.824 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 45 value size: 1 value: 10 09:30:45.827 SERIAL » 0x010a0013100370050a25c966 (12 bytes) 09:30:45.827 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 201 └─[ConfigurationCCGet] parameter #: 10 09:30:45.828 CNTRLR « [Node 015] parameter #45 has value: 10 09:30:45.828 CNTRLR » [Node 015] querying parameter #47 value... 09:30:45.832 SERIAL « [ACK] (0x06) 09:30:45.836 SERIAL « 0x0104011301e8 (6 bytes) 09:30:45.837 SERIAL » [ACK] (0x06) 09:30:45.837 DRIVER « [RES] [SendData] was sent: true 09:30:45.874 SERIAL « 0x01070013c900000426 (9 bytes) 09:30:45.874 SERIAL » [ACK] (0x06) 09:30:45.875 DRIVER « [REQ] [SendData] callback id: 201 transmit status: OK 09:30:45.922 SERIAL « 0x010b000400100570060a010199 (13 bytes) 09:30:45.927 CNTRLR [Node 016] [~] [Configuration] 10: 1 => 1 09:30:45.928 SERIAL » [ACK] (0x06) 09:30:45.929 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 1 09:30:45.933 SERIAL » 0x010900130602984025cad6 (11 bytes) 09:30:45.934 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 202 └─[SecurityCCNonceGet] 09:30:45.934 CNTRLR « [Node 016] parameter #10 has value: 1 09:30:45.934 CNTRLR » [Node 016] querying parameter #12 value... 09:30:45.938 SERIAL « [ACK] (0x06) 09:30:45.943 SERIAL « 0x0104011301e8 (6 bytes) 09:30:45.943 SERIAL » [ACK] (0x06) 09:30:45.944 DRIVER « [RES] [SendData] was sent: true 09:30:46.047 SERIAL « 0x01070013ca00000b2a (9 bytes) 09:30:46.047 SERIAL » [ACK] (0x06) 09:30:46.048 DRIVER « [REQ] [SendData] callback id: 202 transmit status: OK 09:30:46.142 SERIAL « 0x0110000400060a98803737765c6c8e1a3518 (18 bytes) 09:30:46.143 SERIAL » [ACK] (0x06) 09:30:46.143 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x3737765c6c8e1a35 09:30:46.147 SERIAL » 0x01230013061c9881331cc52104d60e972acf78e4f23c7bbd73370b9de800ef844 (37 bytes) fd425cb19 09:30:46.148 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 203 └─[SecurityCCCommandEncapsulation] │ nonce id: 55 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:30:46.151 SERIAL « [ACK] (0x06) 09:30:46.158 SERIAL « 0x0104011301e8 (6 bytes) 09:30:46.158 SERIAL » [ACK] (0x06) 09:30:46.159 DRIVER « [RES] [SendData] was sent: true 09:30:46.269 SERIAL « 0x01070013cb00000b2b (9 bytes) 09:30:46.270 SERIAL » [ACK] (0x06) 09:30:46.271 DRIVER « [REQ] [SendData] callback id: 203 transmit status: OK 09:30:46.348 SERIAL « 0x0108000400060298402f (10 bytes) 09:30:46.349 SERIAL » [ACK] (0x06) 09:30:46.350 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:30:46.360 SERIAL » 0x01110013060a9880a39862e62995c9a72400a0 (19 bytes) 09:30:46.361 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xa39862e62995c9a7 09:30:46.363 SERIAL « [ACK] (0x06) 09:30:46.370 SERIAL « 0x0104011301e8 (6 bytes) 09:30:46.371 SERIAL » [ACK] (0x06) 09:30:46.372 DRIVER « [RES] [SendData] was sent: true 09:30:46.591 SERIAL « 0x0124000400061e988112607f17f170bf1eb81267a7d41b3ea62b5de8a319fa606 (38 bytes) 6c7f926e1f8 09:30:46.593 SERIAL » [ACK] (0x06) 09:30:46.596 CNTRLR [Node 006] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:30:46.597 CNTRLR [Node 006] [~] [Multilevel Sensor] Air temperature: 20.8 => 21.4 [Endpoint 2] 09:30:46.599 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 21.4 09:30:46.606 SERIAL » 0x010a00130c0370050d25cc78 (12 bytes) 09:30:46.607 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 204 └─[ConfigurationCCGet] parameter #: 13 09:30:46.608 CNTRLR « [Node 006] received current Air temperature sensor reading: 21.4 [Endpoint 2] °C 09:30:46.609 CNTRLR [Node 006] [~] [Multilevel Sensor] interviewComplete: [Endpoint 2] [internal] true => true 09:30:46.681 SERIAL « [ACK] (0x06) 09:30:46.686 SERIAL « 0x0104011301e8 (6 bytes) 09:30:46.687 SERIAL » [ACK] (0x06) 09:30:46.688 DRIVER « [RES] [SendData] was sent: true 09:30:46.691 CNTRLR [Node 006] NotificationCC: doing a partial interview... [Endpoint 2] 09:30:46.691 CNTRLR » [Node 006] querying notification status for Power Management... [Endpoint 2] 09:30:46.721 SERIAL « 0x01070013cc00000b2c (9 bytes) 09:30:46.722 SERIAL » [ACK] (0x06) 09:30:46.722 DRIVER « [REQ] [SendData] callback id: 204 transmit status: OK 09:30:46.774 SERIAL « 0x010b0004000c0570060d010182 (13 bytes) 09:30:46.779 CNTRLR [Node 012] [~] [Configuration] 13: 1 => 1 09:30:46.780 SERIAL » [ACK] (0x06) 09:30:46.781 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 1 09:30:46.784 SERIAL » 0x010a00130d0370051d25cd68 (12 bytes) 09:30:46.791 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 205 └─[ConfigurationCCGet] parameter #: 29 09:30:46.791 CNTRLR « [Node 012] parameter #13 has value: 1 09:30:46.792 CNTRLR » [Node 012] querying parameter #14 value... 09:30:46.795 SERIAL « [ACK] (0x06) 09:30:46.800 SERIAL « 0x0104011301e8 (6 bytes) 09:30:46.800 SERIAL » [ACK] (0x06) 09:30:46.801 DRIVER « [RES] [SendData] was sent: true 09:30:46.877 SERIAL « 0x01070013cd0000082e (9 bytes) 09:30:46.878 SERIAL » [ACK] (0x06) 09:30:46.878 DRIVER « [REQ] [SendData] callback id: 205 transmit status: OK 09:30:46.925 SERIAL « 0x010b0004000d0570061d010092 (13 bytes) 09:30:46.931 CNTRLR [Node 013] [~] [Configuration] 29: 0 => 0 09:30:46.932 SERIAL » [ACK] (0x06) 09:30:46.933 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 29 value size: 1 value: 0 09:30:46.938 SERIAL » 0x010a00130e0370051d25ce68 (12 bytes) 09:30:46.938 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 206 └─[ConfigurationCCGet] parameter #: 29 09:30:46.939 CNTRLR « [Node 013] parameter #29 has value: 0 09:30:46.939 CNTRLR » [Node 013] querying parameter #30 value... 09:30:46.943 SERIAL « [ACK] (0x06) 09:30:46.948 SERIAL « 0x0104011301e8 (6 bytes) 09:30:46.948 SERIAL » [ACK] (0x06) 09:30:46.951 DRIVER « [RES] [SendData] was sent: true 09:30:47.006 SERIAL « 0x01070013ce00000623 (9 bytes) 09:30:47.006 SERIAL » [ACK] (0x06) 09:30:47.007 DRIVER « [REQ] [SendData] callback id: 206 transmit status: OK 09:30:47.017 SERIAL « 0x010b0004000e0570061d010091 (13 bytes) 09:30:47.022 CNTRLR [Node 014] [~] [Configuration] 29: 0 => 0 09:30:47.023 SERIAL » [ACK] (0x06) 09:30:47.024 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 29 value size: 1 value: 0 09:30:47.027 SERIAL » 0x010a00130f0370052f25cf5a (12 bytes) 09:30:47.027 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 207 └─[ConfigurationCCGet] parameter #: 47 09:30:47.027 CNTRLR « [Node 014] parameter #29 has value: 0 09:30:47.028 CNTRLR » [Node 014] querying parameter #30 value... 09:30:47.031 SERIAL « [ACK] (0x06) 09:30:47.035 SERIAL « 0x0104011301e8 (6 bytes) 09:30:47.035 SERIAL » [ACK] (0x06) 09:30:47.036 DRIVER « [RES] [SendData] was sent: true 09:30:47.052 SERIAL « 0x01070013cf00000226 (9 bytes) 09:30:47.053 SERIAL » [ACK] (0x06) 09:30:47.053 DRIVER « [REQ] [SendData] callback id: 207 transmit status: OK 09:30:47.063 SERIAL « 0x010c0004000f0670062f020e10bb (14 bytes) 09:30:47.068 CNTRLR [Node 015] [~] [Configuration] 47: 3600 => 3600 09:30:47.069 SERIAL » [ACK] (0x06) 09:30:47.070 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 47 value size: 2 value: 3600 09:30:47.073 SERIAL » 0x010a0013100370050c25d079 (12 bytes) 09:30:47.074 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 208 └─[ConfigurationCCGet] parameter #: 12 09:30:47.074 CNTRLR « [Node 015] parameter #47 has value: 3600 09:30:47.074 CNTRLR » [Node 015] querying parameter #49 value... 09:30:47.077 SERIAL « [ACK] (0x06) 09:30:47.083 SERIAL « 0x0104011301e8 (6 bytes) 09:30:47.084 SERIAL » [ACK] (0x06) 09:30:47.085 DRIVER « [RES] [SendData] was sent: true 09:30:47.123 SERIAL « 0x01070013d00000053e (9 bytes) 09:30:47.123 SERIAL » [ACK] (0x06) 09:30:47.124 DRIVER « [REQ] [SendData] callback id: 208 transmit status: OK 09:30:47.168 SERIAL « 0x010c000400100670060c0200960f (14 bytes) 09:30:47.174 CNTRLR [Node 016] [~] [Configuration] 12: 150 => 150 09:30:47.175 SERIAL » [ACK] (0x06) 09:30:47.175 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 150 09:30:47.180 SERIAL » 0x010900130602984025d1cd (11 bytes) 09:30:47.181 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 209 └─[SecurityCCNonceGet] 09:30:47.181 CNTRLR « [Node 016] parameter #12 has value: 150 09:30:47.181 CNTRLR » [Node 016] querying parameter #13 value... 09:30:47.185 SERIAL « [ACK] (0x06) 09:30:47.192 SERIAL « 0x0104011301e8 (6 bytes) 09:30:47.192 SERIAL » [ACK] (0x06) 09:30:47.193 DRIVER « [RES] [SendData] was sent: true 09:30:47.303 SERIAL « 0x01070013d100000c36 (9 bytes) 09:30:47.303 SERIAL » [ACK] (0x06) 09:30:47.303 DRIVER « [REQ] [SendData] callback id: 209 transmit status: OK 09:30:47.390 SERIAL « 0x0110000400060a9880330238a83bee059618 (18 bytes) 09:30:47.391 SERIAL » [ACK] (0x06) 09:30:47.392 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x330238a83bee0596 09:30:47.398 SERIAL » 0x01240013061d9881f83ef0b037652cf5876c0443f99bcd7d91bb3357b94ce6ccd (38 bytes) 5280a25d228 09:30:47.399 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 210 └─[SecurityCCCommandEncapsulation] │ nonce id: 51 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: Power Management 09:30:47.402 SERIAL « [ACK] (0x06) 09:30:47.410 SERIAL « 0x0104011301e8 (6 bytes) 09:30:47.410 SERIAL » [ACK] (0x06) 09:30:47.411 DRIVER « [RES] [SendData] was sent: true 09:30:47.541 SERIAL « 0x01070013d200000e37 (9 bytes) 09:30:47.542 SERIAL » [ACK] (0x06) 09:30:47.543 DRIVER « [REQ] [SendData] callback id: 210 transmit status: OK 09:30:47.626 SERIAL « 0x0108000400060298402f (10 bytes) 09:30:47.627 SERIAL » [ACK] (0x06) 09:30:47.628 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:30:47.638 SERIAL » 0x01110013060a9880a6bd69be0dd6c1e82400f3 (19 bytes) 09:30:47.639 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xa6bd69be0dd6c1e8 09:30:47.641 SERIAL « [ACK] (0x06) 09:30:47.648 SERIAL « 0x0104011301e8 (6 bytes) 09:30:47.648 SERIAL » [ACK] (0x06) 09:30:47.649 DRIVER « [RES] [SendData] was sent: true 09:30:47.862 SERIAL « 0x012700040006219881e8a045217d5136431bf82dc49e01536554d2e2b06de0a60 (41 bytes) 9277874cb9ba08990 09:30:47.864 SERIAL » [ACK] (0x06) 09:30:47.866 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 09:30:47.876 SERIAL » 0x010a00130c0370050e25d364 (12 bytes) 09:30:47.877 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 211 └─[ConfigurationCCGet] parameter #: 14 09:30:47.878 CNTRLR [Node 006] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 2] 54 09:30:47.880 CNTRLR » [Node 006] querying notification status for System... [Endpoint 2] 09:30:47.885 SERIAL « [ACK] (0x06) 09:30:47.888 SERIAL « 0x0104011301e8 (6 bytes) 09:30:47.889 SERIAL » [ACK] (0x06) 09:30:47.890 DRIVER « [RES] [SendData] was sent: true 09:30:47.992 SERIAL « 0x01070013d300000b33 (9 bytes) 09:30:47.992 SERIAL » [ACK] (0x06) 09:30:47.993 DRIVER « [REQ] [SendData] callback id: 211 transmit status: OK 09:30:48.044 SERIAL « 0x010b0004000c0570060e010080 (13 bytes) 09:30:48.057 CNTRLR [Node 012] [~] [Configuration] 14: 0 => 0 09:30:48.059 SERIAL » [ACK] (0x06) 09:30:48.060 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 0 09:30:48.067 SERIAL » 0x010a00130d0370051e25d472 (12 bytes) 09:30:48.068 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 212 └─[ConfigurationCCGet] parameter #: 30 09:30:48.068 CNTRLR « [Node 012] parameter #14 has value: 0 09:30:48.069 CNTRLR » [Node 012] querying parameter #17 value... 09:30:48.075 SERIAL « [ACK] (0x06) 09:30:48.078 SERIAL « 0x0104011301e8 (6 bytes) 09:30:48.079 SERIAL » [ACK] (0x06) 09:30:48.084 DRIVER « [RES] [SendData] was sent: true 09:30:48.148 SERIAL « 0x01070013d400000738 (9 bytes) 09:30:48.148 SERIAL » [ACK] (0x06) 09:30:48.149 DRIVER « [REQ] [SendData] callback id: 212 transmit status: OK 09:30:48.197 SERIAL « 0x010b0004000d0570061e010293 (13 bytes) 09:30:48.204 CNTRLR [Node 013] [~] [Configuration] 30: 2 => 2 09:30:48.206 SERIAL » [ACK] (0x06) 09:30:48.207 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 2 09:30:48.211 SERIAL » 0x010a00130e0370051e25d570 (12 bytes) 09:30:48.211 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 213 └─[ConfigurationCCGet] parameter #: 30 09:30:48.212 CNTRLR « [Node 013] parameter #30 has value: 2 09:30:48.212 CNTRLR » [Node 013] querying parameter #31 value... 09:30:48.217 SERIAL « [ACK] (0x06) 09:30:48.220 SERIAL « 0x0104011301e8 (6 bytes) 09:30:48.222 SERIAL » [ACK] (0x06) 09:30:48.224 DRIVER « [RES] [SendData] was sent: true 09:30:48.287 SERIAL « 0x01070013d500000739 (9 bytes) 09:30:48.287 SERIAL » [ACK] (0x06) 09:30:48.288 DRIVER « [REQ] [SendData] callback id: 213 transmit status: OK 09:30:48.297 SERIAL « 0x010b0004000e0570061e010290 (13 bytes) 09:30:48.307 CNTRLR [Node 014] [~] [Configuration] 30: 2 => 2 09:30:48.309 SERIAL » [ACK] (0x06) 09:30:48.311 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 2 09:30:48.316 SERIAL » 0x010a00130f0370053125d65d (12 bytes) 09:30:48.317 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 214 └─[ConfigurationCCGet] parameter #: 49 09:30:48.317 CNTRLR « [Node 014] parameter #30 has value: 2 09:30:48.318 CNTRLR » [Node 014] querying parameter #31 value... 09:30:48.328 SERIAL « [ACK] (0x06) 09:30:48.329 SERIAL « 0x0104011301e8 (6 bytes) 09:30:48.330 SERIAL » [ACK] (0x06) 09:30:48.332 DRIVER « [RES] [SendData] was sent: true 09:30:48.342 SERIAL « 0x01070013d60000033e (9 bytes) 09:30:48.343 SERIAL » [ACK] (0x06) 09:30:48.343 DRIVER « [REQ] [SendData] callback id: 214 transmit status: OK 09:30:48.353 SERIAL « 0x010b0004000f057006310100bc (13 bytes) 09:30:48.361 CNTRLR [Node 015] [~] [Configuration] 49: 0 => 0 09:30:48.362 SERIAL » [ACK] (0x06) 09:30:48.363 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 49 value size: 1 value: 0 09:30:48.373 SERIAL » 0x010a0013100370050d25d77f (12 bytes) 09:30:48.374 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 215 └─[ConfigurationCCGet] parameter #: 13 09:30:48.374 CNTRLR « [Node 015] parameter #49 has value: 0 09:30:48.374 CNTRLR » [Node 015] querying parameter #50 value... 09:30:48.386 SERIAL « [ACK] (0x06) 09:30:48.388 SERIAL « 0x0104011301e8 (6 bytes) 09:30:48.388 SERIAL » [ACK] (0x06) 09:30:48.389 DRIVER « [RES] [SendData] was sent: true 09:30:48.420 SERIAL « 0x01070013d700000539 (9 bytes) 09:30:48.421 SERIAL » [ACK] (0x06) 09:30:48.421 DRIVER « [REQ] [SendData] callback id: 215 transmit status: OK 09:30:48.468 SERIAL « 0x010b000400100570060d01019e (13 bytes) 09:30:48.476 CNTRLR [Node 016] [~] [Configuration] 13: 1 => 1 09:30:48.477 SERIAL » [ACK] (0x06) 09:30:48.478 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 1 09:30:48.485 SERIAL » 0x010900130602984025d8c4 (11 bytes) 09:30:48.486 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 216 └─[SecurityCCNonceGet] 09:30:48.486 CNTRLR « [Node 016] parameter #13 has value: 1 09:30:48.487 CNTRLR » [Node 016] querying parameter #14 value... 09:30:48.492 SERIAL « [ACK] (0x06) 09:30:48.495 SERIAL « 0x0104011301e8 (6 bytes) 09:30:48.495 SERIAL » [ACK] (0x06) 09:30:48.497 DRIVER « [RES] [SendData] was sent: true 09:30:48.598 SERIAL « 0x01070013d800000b38 (9 bytes) 09:30:48.598 SERIAL » [ACK] (0x06) 09:30:48.599 DRIVER « [REQ] [SendData] callback id: 216 transmit status: OK 09:30:48.681 SERIAL « 0x0110000400060a9880c35e6b39ceb33f4537 (18 bytes) 09:30:48.682 SERIAL » [ACK] (0x06) 09:30:48.683 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xc35e6b39ceb33f45 09:30:48.690 SERIAL » 0x01240013061d9881a44bba2fb1eb14667a6a836869bf8c07bcc4c3673d46d05df (38 bytes) 3a64225d9ff 09:30:48.691 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 217 └─[SecurityCCCommandEncapsulation] │ nonce id: 195 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:30:48.695 SERIAL « [ACK] (0x06) 09:30:48.702 SERIAL « 0x0104011301e8 (6 bytes) 09:30:48.703 SERIAL » [ACK] (0x06) 09:30:48.704 DRIVER « [RES] [SendData] was sent: true 09:30:48.830 SERIAL « 0x01070013d900000d3f (9 bytes) 09:30:48.830 SERIAL » [ACK] (0x06) 09:30:48.831 DRIVER « [REQ] [SendData] callback id: 217 transmit status: OK 09:30:50.436 CNTRLR [Node 006] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:30:50.946 SERIAL » 0x010900130602984025dac6 (11 bytes) 09:30:50.947 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 218 └─[SecurityCCNonceGet] 09:30:50.949 SERIAL « [ACK] (0x06) 09:30:50.955 SERIAL « 0x0104011301e8 (6 bytes) 09:30:50.956 SERIAL » [ACK] (0x06) 09:30:50.957 DRIVER « [RES] [SendData] was sent: true 09:30:52.361 SERIAL « 0x01070013da00008dbc (9 bytes) 09:30:52.362 SERIAL » [ACK] (0x06) 09:30:52.363 DRIVER « [REQ] [SendData] callback id: 218 transmit status: OK 09:30:52.448 SERIAL « 0x0110000400060a9880595674d94293493aff (18 bytes) 09:30:52.448 SERIAL » [ACK] (0x06) 09:30:52.450 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x595674d94293493a 09:30:52.455 SERIAL » 0x01240013061d988181f6bf34c184292efc6d788daff290af170d5948124782402 (38 bytes) 0bdc725d948 09:30:52.456 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 217 └─[SecurityCCCommandEncapsulation] │ nonce id: 89 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:30:52.460 SERIAL « [ACK] (0x06) 09:30:52.467 SERIAL « 0x0104011301e8 (6 bytes) 09:30:52.468 SERIAL » [ACK] (0x06) 09:30:52.469 DRIVER « [RES] [SendData] was sent: true 09:30:52.589 SERIAL « 0x01070013d900000c3e (9 bytes) 09:30:52.589 SERIAL » [ACK] (0x06) 09:30:52.590 DRIVER « [REQ] [SendData] callback id: 217 transmit status: OK 09:30:54.193 CNTRLR [Node 006] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:30:54.704 SERIAL » 0x010900130602984025dbc7 (11 bytes) 09:30:54.705 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 219 └─[SecurityCCNonceGet] 09:30:54.707 SERIAL « [ACK] (0x06) 09:30:54.713 SERIAL « 0x0104011301e8 (6 bytes) 09:30:54.714 SERIAL » [ACK] (0x06) 09:30:54.715 DRIVER « [RES] [SendData] was sent: true 09:30:56.119 SERIAL « 0x01070013db00008dbd (9 bytes) 09:30:56.120 SERIAL » [ACK] (0x06) 09:30:56.121 DRIVER « [REQ] [SendData] callback id: 219 transmit status: OK 09:30:56.203 SERIAL « 0x0110000400060a98807d6f250f43b55bbcd6 (18 bytes) 09:30:56.204 SERIAL » [ACK] (0x06) 09:30:56.206 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x7d6f250f43b55bbc 09:30:56.213 SERIAL » 0x01240013061d98818c0f9aa5a82196173bc79f6dff5d0e9c66c67d855556476b2 (38 bytes) 3444825d9e4 09:30:56.214 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 217 └─[SecurityCCCommandEncapsulation] │ nonce id: 125 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:30:56.218 SERIAL « [ACK] (0x06) 09:30:56.225 SERIAL « 0x0104011301e8 (6 bytes) 09:30:56.226 SERIAL » [ACK] (0x06) 09:30:56.227 DRIVER « [RES] [SendData] was sent: true 09:30:56.295 SERIAL « 0x010c00040003063105042204d531 (14 bytes) 09:30:56.296 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:30:56.298 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 190.2 => 123.7 [Endpoint 0] 09:30:56.298 SERIAL » [ACK] (0x06) 09:30:56.300 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 123.7 09:30:56.439 SERIAL « 0x01070013d900001624 (9 bytes) 09:30:56.440 SERIAL » [ACK] (0x06) 09:30:56.441 DRIVER « [REQ] [SendData] callback id: 217 transmit status: OK 09:30:57.294 SERIAL « 0x010c00040003063105042208e30b (14 bytes) 09:30:57.295 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:30:57.296 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 123.7 => 227.5 [Endpoint 0] 09:30:57.298 SERIAL » [ACK] (0x06) 09:30:57.300 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 227.5 09:30:58.048 SERIAL » 0x010a00130c0370051125dc74 (12 bytes) 09:30:58.049 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 220 └─[ConfigurationCCGet] parameter #: 17 09:30:58.049 CNTRLR [Node 006] Interview attempt 2/5 failed, retrying in 10000 ms... 09:30:58.050 SERIAL « [ACK] (0x06) 09:30:58.057 SERIAL « 0x0104011301e8 (6 bytes) 09:30:58.057 SERIAL » [ACK] (0x06) 09:30:58.057 DRIVER « [RES] [SendData] was sent: true 09:30:58.119 SERIAL « 0x01070013dc00000631 (9 bytes) 09:30:58.120 SERIAL » [ACK] (0x06) 09:30:58.120 DRIVER « [REQ] [SendData] callback id: 220 transmit status: OK 09:30:58.174 SERIAL « 0x010b0004000c05700611010a95 (13 bytes) 09:30:58.179 CNTRLR [Node 012] [~] [Configuration] 17: 10 => 10 09:30:58.180 SERIAL » [ACK] (0x06) 09:30:58.181 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 17 value size: 1 value: 10 09:30:58.184 SERIAL » 0x010a00130d0370051f25dd7a (12 bytes) 09:30:58.185 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 221 └─[ConfigurationCCGet] parameter #: 31 09:30:58.185 CNTRLR « [Node 012] parameter #17 has value: 10 09:30:58.185 CNTRLR » [Node 012] querying parameter #18 value... 09:30:58.189 SERIAL « [ACK] (0x06) 09:30:58.197 SERIAL « 0x0104011301e8 (6 bytes) 09:30:58.197 SERIAL » [ACK] (0x06) 09:30:58.198 DRIVER « [RES] [SendData] was sent: true 09:30:58.278 SERIAL « 0x01070013dd0000093f (9 bytes) 09:30:58.278 SERIAL » [ACK] (0x06) 09:30:58.279 DRIVER « [REQ] [SendData] callback id: 221 transmit status: OK 09:30:58.326 SERIAL « 0x010b0004000d0570061f010090 (13 bytes) 09:30:58.331 CNTRLR [Node 013] [~] [Configuration] 31: 0 => 0 09:30:58.333 SERIAL » [ACK] (0x06) 09:30:58.335 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 0 09:30:58.338 SERIAL » 0x010a00130e0370051f25de7a (12 bytes) 09:30:58.338 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 222 └─[ConfigurationCCGet] parameter #: 31 09:30:58.339 CNTRLR « [Node 013] parameter #31 has value: 0 09:30:58.339 CNTRLR » [Node 013] querying parameter #32 value... 09:30:58.349 SERIAL « [ACK] (0x06) 09:30:58.350 SERIAL « 0x0104011301e8 (6 bytes) 09:30:58.350 SERIAL » [ACK] (0x06) 09:30:58.352 DRIVER « [RES] [SendData] was sent: true 09:30:58.396 SERIAL « 0x01070013de00000530 (9 bytes) 09:30:58.397 SERIAL » [ACK] (0x06) 09:30:58.397 DRIVER « [REQ] [SendData] callback id: 222 transmit status: OK 09:30:58.407 SERIAL « 0x010b0004000e0570061f010093 (13 bytes) 09:30:58.412 CNTRLR [Node 014] [~] [Configuration] 31: 0 => 0 09:30:58.414 SERIAL » [ACK] (0x06) 09:30:58.415 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 0 09:30:58.418 SERIAL » 0x010a00130f0370053225df57 (12 bytes) 09:30:58.419 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 223 └─[ConfigurationCCGet] parameter #: 50 09:30:58.419 CNTRLR « [Node 014] parameter #31 has value: 0 09:30:58.419 CNTRLR » [Node 014] querying parameter #32 value... 09:30:58.425 SERIAL « [ACK] (0x06) 09:30:58.427 SERIAL « 0x0104011301e8 (6 bytes) 09:30:58.427 SERIAL » [ACK] (0x06) 09:30:58.429 DRIVER « [RES] [SendData] was sent: true 09:30:58.444 SERIAL « 0x01070013df00000236 (9 bytes) 09:30:58.444 SERIAL » [ACK] (0x06) 09:30:58.445 DRIVER « [REQ] [SendData] callback id: 223 transmit status: OK 09:30:58.455 SERIAL « 0x010c0004000f0670063202012c95 (14 bytes) 09:30:58.460 CNTRLR [Node 015] [~] [Configuration] 50: 300 => 300 09:30:58.461 SERIAL » [ACK] (0x06) 09:30:58.462 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 2 value: 300 09:30:58.469 SERIAL » 0x010a0013100370050e25e04b (12 bytes) 09:30:58.469 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 224 └─[ConfigurationCCGet] parameter #: 14 09:30:58.470 CNTRLR « [Node 015] parameter #50 has value: 300 09:30:58.470 CNTRLR » [Node 015] querying parameter #51 value... 09:30:58.475 SERIAL « [ACK] (0x06) 09:30:58.482 SERIAL « 0x0104011301e8 (6 bytes) 09:30:58.482 SERIAL » [ACK] (0x06) 09:30:58.484 DRIVER « [RES] [SendData] was sent: true 09:30:58.516 SERIAL « 0x01070013e00000040f (9 bytes) 09:30:58.516 SERIAL » [ACK] (0x06) 09:30:58.517 DRIVER « [REQ] [SendData] callback id: 224 transmit status: OK 09:30:58.565 SERIAL « 0x010b000400100570060e01009c (13 bytes) 09:30:58.576 CNTRLR [Node 016] [~] [Configuration] 14: 0 => 0 09:30:58.577 SERIAL » [ACK] (0x06) 09:30:58.578 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 0 09:30:58.583 SERIAL » 0x010a00130c0370051225e14a (12 bytes) 09:30:58.584 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 225 └─[ConfigurationCCGet] parameter #: 18 09:30:58.584 CNTRLR « [Node 016] parameter #14 has value: 0 09:30:58.585 CNTRLR » [Node 016] querying parameter #17 value... 09:30:58.589 SERIAL « [ACK] (0x06) 09:30:58.603 SERIAL « 0x0104011301e8 (6 bytes) 09:30:58.603 SERIAL » [ACK] (0x06) 09:30:58.604 DRIVER « [RES] [SendData] was sent: true 09:30:58.691 SERIAL « 0x01070013e100000b01 (9 bytes) 09:30:58.692 SERIAL » [ACK] (0x06) 09:30:58.692 DRIVER « [REQ] [SendData] callback id: 225 transmit status: OK 09:30:58.733 SERIAL « 0x01080004000202840770 (10 bytes) 09:30:58.734 SERIAL » [ACK] (0x06) 09:30:58.735 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:30:58.736 CNTRLR « [Node 002] received wakeup notification 09:30:58.737 CNTRLR [Node 002] The node is now awake. 09:30:58.839 SERIAL « 0x010b0004000c05700612010a96 (13 bytes) 09:30:58.845 CNTRLR [Node 012] [~] [Configuration] 18: 10 => 10 09:30:58.846 SERIAL » [ACK] (0x06) 09:30:58.847 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 18 value size: 1 value: 10 09:30:58.853 SERIAL » 0x010a00130d0370052025e27a (12 bytes) 09:30:58.854 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 226 └─[ConfigurationCCGet] parameter #: 32 09:30:58.854 CNTRLR « [Node 012] parameter #18 has value: 10 09:30:58.854 CNTRLR » [Node 012] querying parameter #22 value... 09:30:58.861 SERIAL « [ACK] (0x06) 09:30:58.863 SERIAL « 0x0104011301e8 (6 bytes) 09:30:58.863 SERIAL » [ACK] (0x06) 09:30:58.865 DRIVER « [RES] [SendData] was sent: true 09:30:58.948 SERIAL « 0x01070013e200000900 (9 bytes) 09:30:58.948 SERIAL » [ACK] (0x06) 09:30:58.948 DRIVER « [REQ] [SendData] callback id: 226 transmit status: OK 09:30:58.996 SERIAL « 0x010b0004000d057006200101ae (13 bytes) 09:30:59.001 CNTRLR [Node 013] [~] [Configuration] 32: 1 => 1 09:30:59.002 SERIAL » [ACK] (0x06) 09:30:59.003 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 1 value: 1 09:30:59.006 SERIAL » 0x010a00130e0370052025e378 (12 bytes) 09:30:59.007 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 227 └─[ConfigurationCCGet] parameter #: 32 09:30:59.007 CNTRLR « [Node 013] parameter #32 has value: 1 09:30:59.007 CNTRLR » [Node 013] querying parameter #33 value... 09:30:59.014 SERIAL « [ACK] (0x06) 09:30:59.017 SERIAL « 0x0104011301e8 (6 bytes) 09:30:59.017 SERIAL » [ACK] (0x06) 09:30:59.018 DRIVER « [RES] [SendData] was sent: true 09:30:59.086 SERIAL « 0x01070013e30000070f (9 bytes) 09:30:59.087 SERIAL » [ACK] (0x06) 09:30:59.087 DRIVER « [REQ] [SendData] callback id: 227 transmit status: OK 09:30:59.097 SERIAL « 0x010b0004000e057006200101ad (13 bytes) 09:30:59.102 CNTRLR [Node 014] [~] [Configuration] 32: 1 => 1 09:30:59.103 SERIAL » [ACK] (0x06) 09:30:59.104 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 1 value: 1 09:30:59.107 SERIAL » 0x010a00130f0370053325e46d (12 bytes) 09:30:59.108 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 228 └─[ConfigurationCCGet] parameter #: 51 09:30:59.108 CNTRLR « [Node 014] parameter #32 has value: 1 09:30:59.108 CNTRLR » [Node 014] querying parameter #33 value... 09:30:59.112 SERIAL « [ACK] (0x06) 09:30:59.116 SERIAL « 0x0104011301e8 (6 bytes) 09:30:59.116 SERIAL » [ACK] (0x06) 09:30:59.119 DRIVER « [RES] [SendData] was sent: true 09:30:59.133 SERIAL « 0x01070013e40000020d (9 bytes) 09:30:59.133 SERIAL » [ACK] (0x06) 09:30:59.136 DRIVER « [REQ] [SendData] callback id: 228 transmit status: OK 09:30:59.144 SERIAL « 0x010c0004000f067006330201f44c (14 bytes) 09:30:59.149 CNTRLR [Node 015] [~] [Configuration] 51: 500 => 500 09:30:59.150 SERIAL » [ACK] (0x06) 09:30:59.151 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 51 value size: 2 value: 500 09:30:59.154 SERIAL » 0x010a0013100370051125e551 (12 bytes) 09:30:59.155 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 229 └─[ConfigurationCCGet] parameter #: 17 09:30:59.155 CNTRLR « [Node 015] parameter #51 has value: 500 09:30:59.155 CNTRLR » [Node 015] querying parameter #52 value... 09:30:59.159 SERIAL « [ACK] (0x06) 09:30:59.163 SERIAL « 0x0104011301e8 (6 bytes) 09:30:59.163 SERIAL » [ACK] (0x06) 09:30:59.164 DRIVER « [RES] [SendData] was sent: true 09:30:59.201 SERIAL « 0x01070013e50000050b (9 bytes) 09:30:59.201 SERIAL » [ACK] (0x06) 09:30:59.202 DRIVER « [REQ] [SendData] callback id: 229 transmit status: OK 09:30:59.248 SERIAL « 0x010b0004001005700611010a89 (13 bytes) 09:30:59.255 CNTRLR [Node 016] [~] [Configuration] 17: 10 => 10 09:30:59.256 SERIAL » [ACK] (0x06) 09:30:59.257 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 17 value size: 1 value: 10 09:30:59.261 SERIAL » 0x010a00130c0370051625e649 (12 bytes) 09:30:59.263 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 230 └─[ConfigurationCCGet] parameter #: 22 09:30:59.264 CNTRLR « [Node 016] parameter #17 has value: 10 09:30:59.264 CNTRLR » [Node 016] querying parameter #18 value... 09:30:59.268 SERIAL « [ACK] (0x06) 09:30:59.271 SERIAL « 0x0104011301e8 (6 bytes) 09:30:59.272 SERIAL » [ACK] (0x06) 09:30:59.273 DRIVER « [RES] [SendData] was sent: true 09:30:59.392 SERIAL « 0x01070013e600000d00 (9 bytes) 09:30:59.392 SERIAL » [ACK] (0x06) 09:30:59.393 DRIVER « [REQ] [SendData] callback id: 230 transmit status: OK 09:30:59.445 SERIAL « 0x010c0004000c067006160200f06f (14 bytes) 09:30:59.455 CNTRLR [Node 012] [~] [Configuration] 22: 240 => 240 09:30:59.457 SERIAL » [ACK] (0x06) 09:30:59.458 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 240 09:30:59.464 SERIAL » 0x010a00130d0370052125e77e (12 bytes) 09:30:59.465 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 231 └─[ConfigurationCCGet] parameter #: 33 09:30:59.465 CNTRLR « [Node 012] parameter #22 has value: 240 09:30:59.466 CNTRLR » [Node 012] querying parameter #29 value... 09:30:59.475 SERIAL « [ACK] (0x06) 09:30:59.476 SERIAL « 0x0104011301e8 (6 bytes) 09:30:59.476 SERIAL » [ACK] (0x06) 09:30:59.478 DRIVER « [RES] [SendData] was sent: true 09:30:59.836 SERIAL « 0x010b0004000d057006210101af (13 bytes) 09:30:59.848 CNTRLR [Node 013] [~] [Configuration] 33: 1 => 1 09:30:59.850 SERIAL » [ACK] (0x06) 09:30:59.852 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 1 value: 1 09:30:59.879 SERIAL « 0x01070013e700002925 (9 bytes) 09:30:59.880 SERIAL » [ACK] (0x06) 09:30:59.881 DRIVER « [REQ] [SendData] callback id: 231 transmit status: OK 09:30:59.889 SERIAL « 0x010b0004000d057006210101af (13 bytes) 09:30:59.902 CNTRLR [Node 013] [~] [Configuration] 33: 1 => 1 09:30:59.904 SERIAL » [ACK] (0x06) 09:30:59.914 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 1 value: 1 09:30:59.921 SERIAL » 0x010a00130e0370052125e872 (12 bytes) 09:30:59.925 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 232 └─[ConfigurationCCGet] parameter #: 33 09:30:59.926 CNTRLR « [Node 013] parameter #33 has value: 1 09:30:59.926 CNTRLR » [Node 013] querying parameter #35 value... 09:30:59.932 SERIAL « 0x010c000400030631050422076a8d (14 bytes) 09:30:59.933 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:30:59.934 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 227.5 => 189.8 [Endpoint 0] 09:30:59.935 SERIAL » [ACK] (0x06) 09:30:59.935 SERIAL « [CAN] (0x18) 09:30:59.937 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 09:30:59.939 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 189.8 09:31:00.038 SERIAL » 0x010a00130e0370052125e872 (12 bytes) 09:31:00.039 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 232 └─[ConfigurationCCGet] parameter #: 33 09:31:00.040 SERIAL « [ACK] (0x06) 09:31:00.047 SERIAL « 0x0104011301e8 (6 bytes) 09:31:00.047 SERIAL » [ACK] (0x06) 09:31:00.048 DRIVER « [RES] [SendData] was sent: true 09:31:00.064 SERIAL « 0x01070013e800000201 (9 bytes) 09:31:00.064 SERIAL » [ACK] (0x06) 09:31:00.065 DRIVER « [REQ] [SendData] callback id: 232 transmit status: OK 09:31:00.075 SERIAL « 0x010b0004000e057006210101ac (13 bytes) 09:31:00.080 CNTRLR [Node 014] [~] [Configuration] 33: 1 => 1 09:31:00.081 SERIAL » [ACK] (0x06) 09:31:00.081 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 1 value: 1 09:31:00.085 SERIAL » 0x010a00130f0370053425e967 (12 bytes) 09:31:00.085 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 233 └─[ConfigurationCCGet] parameter #: 52 09:31:00.086 CNTRLR « [Node 014] parameter #33 has value: 1 09:31:00.086 CNTRLR » [Node 014] querying parameter #35 value... 09:31:00.091 SERIAL « [ACK] (0x06) 09:31:00.093 SERIAL « 0x0104011301e8 (6 bytes) 09:31:00.094 SERIAL » [ACK] (0x06) 09:31:00.095 DRIVER « [RES] [SendData] was sent: true 09:31:00.110 SERIAL « 0x01070013e900000301 (9 bytes) 09:31:00.111 SERIAL » [ACK] (0x06) 09:31:00.111 DRIVER « [REQ] [SendData] callback id: 233 transmit status: OK 09:31:00.121 SERIAL « 0x010b0004000f057006340106bf (13 bytes) 09:31:00.126 CNTRLR [Node 015] [~] [Configuration] 52: 6 => 6 09:31:00.127 SERIAL » [ACK] (0x06) 09:31:00.128 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 52 value size: 1 value: 6 09:31:00.131 SERIAL » 0x010a0013100370051225ea5d (12 bytes) 09:31:00.131 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 234 └─[ConfigurationCCGet] parameter #: 18 09:31:00.132 CNTRLR « [Node 015] parameter #52 has value: 6 09:31:00.132 CNTRLR » [Node 015] querying parameter #60 value... 09:31:00.136 SERIAL « [ACK] (0x06) 09:31:00.141 SERIAL « 0x0104011301e8 (6 bytes) 09:31:00.141 SERIAL » [ACK] (0x06) 09:31:00.142 DRIVER « [RES] [SendData] was sent: true 09:31:00.178 SERIAL « 0x01070013ea00000405 (9 bytes) 09:31:00.178 SERIAL » [ACK] (0x06) 09:31:00.179 DRIVER « [REQ] [SendData] callback id: 234 transmit status: OK 09:31:00.225 SERIAL « 0x010b0004001005700612010a8a (13 bytes) 09:31:00.230 CNTRLR [Node 016] [~] [Configuration] 18: 10 => 10 09:31:00.231 SERIAL » [ACK] (0x06) 09:31:00.232 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 18 value size: 1 value: 10 09:31:00.235 SERIAL » 0x010a00130c0370051d25eb4f (12 bytes) 09:31:00.236 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 235 └─[ConfigurationCCGet] parameter #: 29 09:31:00.236 CNTRLR « [Node 016] parameter #18 has value: 10 09:31:00.236 CNTRLR » [Node 016] querying parameter #22 value... 09:31:00.241 SERIAL « [ACK] (0x06) 09:31:00.247 SERIAL « 0x0104011301e8 (6 bytes) 09:31:00.247 SERIAL » [ACK] (0x06) 09:31:00.250 DRIVER « [RES] [SendData] was sent: true 09:31:00.352 SERIAL « 0x01070013eb00000c0c (9 bytes) 09:31:00.352 SERIAL » [ACK] (0x06) 09:31:00.353 DRIVER « [REQ] [SendData] callback id: 235 transmit status: OK 09:31:00.406 SERIAL « 0x010b0004000c0570061d010093 (13 bytes) 09:31:00.413 CNTRLR [Node 012] [~] [Configuration] 29: 0 => 0 09:31:00.414 SERIAL » [ACK] (0x06) 09:31:00.415 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 29 value size: 1 value: 0 09:31:00.433 SERIAL » 0x010a00130d0370052325ec77 (12 bytes) 09:31:00.433 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 236 └─[ConfigurationCCGet] parameter #: 35 09:31:00.434 CNTRLR « [Node 012] parameter #29 has value: 0 09:31:00.434 CNTRLR » [Node 012] querying parameter #30 value... 09:31:00.441 SERIAL « [ACK] (0x06) 09:31:00.443 SERIAL « 0x0104011301e8 (6 bytes) 09:31:00.443 SERIAL » [ACK] (0x06) 09:31:00.445 DRIVER « [RES] [SendData] was sent: true 09:31:00.497 SERIAL « 0x01070013ec00000601 (9 bytes) 09:31:00.497 SERIAL » [ACK] (0x06) 09:31:00.498 DRIVER « [REQ] [SendData] callback id: 236 transmit status: OK 09:31:00.507 SERIAL « 0x010b0004000d057006230101ad (13 bytes) 09:31:00.512 CNTRLR [Node 013] [~] [Configuration] 35: 1 => 1 09:31:00.513 SERIAL » [ACK] (0x06) 09:31:00.514 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 1 09:31:00.520 SERIAL » 0x010a00130e0370052325ed75 (12 bytes) 09:31:00.521 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 237 └─[ConfigurationCCGet] parameter #: 35 09:31:00.521 CNTRLR « [Node 013] parameter #35 has value: 1 09:31:00.521 CNTRLR » [Node 013] querying parameter #40 value... 09:31:00.524 SERIAL « [ACK] (0x06) 09:31:00.529 SERIAL « 0x0104011301e8 (6 bytes) 09:31:00.529 SERIAL » [ACK] (0x06) 09:31:00.530 DRIVER « [RES] [SendData] was sent: true 09:31:00.546 SERIAL « 0x01070013ed00000204 (9 bytes) 09:31:00.546 SERIAL » [ACK] (0x06) 09:31:00.547 DRIVER « [REQ] [SendData] callback id: 237 transmit status: OK 09:31:00.557 SERIAL « 0x010b0004000e057006230101ae (13 bytes) 09:31:00.562 CNTRLR [Node 014] [~] [Configuration] 35: 1 => 1 09:31:00.563 SERIAL » [ACK] (0x06) 09:31:00.578 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 1 09:31:00.581 SERIAL » 0x010a00130f0370053c25ee68 (12 bytes) 09:31:00.581 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 238 └─[ConfigurationCCGet] parameter #: 60 09:31:00.582 CNTRLR « [Node 014] parameter #35 has value: 1 09:31:00.582 CNTRLR » [Node 014] querying parameter #40 value... 09:31:00.585 SERIAL « [ACK] (0x06) 09:31:00.589 SERIAL « 0x0104011301e8 (6 bytes) 09:31:00.590 SERIAL » [ACK] (0x06) 09:31:00.591 DRIVER « [RES] [SendData] was sent: true 09:31:00.607 SERIAL « 0x01070013ee00000207 (9 bytes) 09:31:00.607 SERIAL » [ACK] (0x06) 09:31:00.608 DRIVER « [REQ] [SendData] callback id: 238 transmit status: OK 09:31:00.618 SERIAL « 0x010c0004000f0670063c0261a87f (14 bytes) 09:31:00.623 CNTRLR [Node 015] [~] [Configuration] 60: 25000 => 25000 09:31:00.624 SERIAL » [ACK] (0x06) 09:31:00.625 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 2 value: 25000 09:31:00.628 SERIAL » 0x010a0013100370051625ef5c (12 bytes) 09:31:00.629 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 239 └─[ConfigurationCCGet] parameter #: 22 09:31:00.629 CNTRLR « [Node 015] parameter #60 has value: 25000 09:31:00.629 CNTRLR » [Node 015] querying parameter #61 value... 09:31:00.635 SERIAL « [ACK] (0x06) 09:31:00.638 SERIAL « 0x0104011301e8 (6 bytes) 09:31:00.639 SERIAL » [ACK] (0x06) 09:31:00.640 DRIVER « [RES] [SendData] was sent: true 09:31:00.675 SERIAL « 0x01070013ef00000400 (9 bytes) 09:31:00.676 SERIAL » [ACK] (0x06) 09:31:00.677 DRIVER « [REQ] [SendData] callback id: 239 transmit status: OK 09:31:00.724 SERIAL « 0x010c00040010067006160200f073 (14 bytes) 09:31:00.732 CNTRLR [Node 016] [~] [Configuration] 22: 240 => 240 09:31:00.736 SERIAL » [ACK] (0x06) 09:31:00.737 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 240 09:31:00.741 SERIAL » 0x010a00130c0370051e25f057 (12 bytes) 09:31:00.742 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 240 └─[ConfigurationCCGet] parameter #: 30 09:31:00.742 CNTRLR « [Node 016] parameter #22 has value: 240 09:31:00.742 CNTRLR » [Node 016] querying parameter #29 value... 09:31:00.747 SERIAL « [ACK] (0x06) 09:31:00.751 SERIAL « 0x0104011301e8 (6 bytes) 09:31:00.751 SERIAL » [ACK] (0x06) 09:31:00.753 DRIVER « [RES] [SendData] was sent: true 09:31:00.852 SERIAL « 0x01070013f000000b10 (9 bytes) 09:31:00.852 SERIAL » [ACK] (0x06) 09:31:00.853 DRIVER « [REQ] [SendData] callback id: 240 transmit status: OK 09:31:00.906 SERIAL « 0x010b0004000c0570061e010292 (13 bytes) 09:31:00.913 CNTRLR [Node 012] [~] [Configuration] 30: 2 => 2 09:31:00.915 SERIAL » [ACK] (0x06) 09:31:00.916 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 2 09:31:00.921 SERIAL » 0x010a00130d0370052825f161 (12 bytes) 09:31:00.921 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 241 └─[ConfigurationCCGet] parameter #: 40 09:31:00.922 CNTRLR « [Node 012] parameter #30 has value: 2 09:31:00.922 CNTRLR » [Node 012] querying parameter #31 value... 09:31:00.931 SERIAL « [ACK] (0x06) 09:31:00.933 SERIAL « 0x0104011301e8 (6 bytes) 09:31:00.933 SERIAL » [ACK] (0x06) 09:31:00.935 DRIVER « [RES] [SendData] was sent: true 09:31:00.956 SERIAL « 0x01070013f100000319 (9 bytes) 09:31:00.957 SERIAL » [ACK] (0x06) 09:31:00.958 DRIVER « [REQ] [SendData] callback id: 241 transmit status: OK 09:31:00.967 SERIAL « 0x010b0004000d05700628010aad (13 bytes) 09:31:00.975 CNTRLR [Node 013] [~] [Configuration] 40: 10 => 10 09:31:00.976 SERIAL » [ACK] (0x06) 09:31:00.977 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 10 09:31:00.982 SERIAL » 0x010a00130e0370052825f261 (12 bytes) 09:31:00.982 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 242 └─[ConfigurationCCGet] parameter #: 40 09:31:00.983 CNTRLR « [Node 013] parameter #40 has value: 10 09:31:00.983 CNTRLR » [Node 013] querying parameter #42 value... 09:31:00.989 SERIAL « [ACK] (0x06) 09:31:00.993 SERIAL « 0x0104011301e8 (6 bytes) 09:31:00.993 SERIAL » [ACK] (0x06) 09:31:00.995 DRIVER « [RES] [SendData] was sent: true 09:31:01.008 SERIAL « 0x01070013f20000021b (9 bytes) 09:31:01.008 SERIAL » [ACK] (0x06) 09:31:01.009 DRIVER « [REQ] [SendData] callback id: 242 transmit status: OK 09:31:01.019 SERIAL « 0x010b0004000e05700628010aae (13 bytes) 09:31:01.026 CNTRLR [Node 014] [~] [Configuration] 40: 10 => 10 09:31:01.027 SERIAL » [ACK] (0x06) 09:31:01.028 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 10 09:31:01.033 SERIAL » 0x010a00130f0370053d25f374 (12 bytes) 09:31:01.033 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 243 └─[ConfigurationCCGet] parameter #: 61 09:31:01.034 CNTRLR « [Node 014] parameter #40 has value: 10 09:31:01.034 CNTRLR » [Node 014] querying parameter #42 value... 09:31:01.039 SERIAL « [ACK] (0x06) 09:31:01.043 SERIAL « 0x0104011301e8 (6 bytes) 09:31:01.043 SERIAL » [ACK] (0x06) 09:31:01.046 DRIVER « [RES] [SendData] was sent: true 09:31:01.059 SERIAL « 0x01070013f30000021a (9 bytes) 09:31:01.059 SERIAL » [ACK] (0x06) 09:31:01.060 DRIVER « [REQ] [SendData] callback id: 243 transmit status: OK 09:31:01.069 SERIAL « 0x010b0004000f0570063d0101b1 (13 bytes) 09:31:01.075 CNTRLR [Node 015] [~] [Configuration] 61: 1 => 1 09:31:01.075 SERIAL » [ACK] (0x06) 09:31:01.076 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 61 value size: 1 value: 1 09:31:01.079 SERIAL » 0x010a0013100370051d25f44c (12 bytes) 09:31:01.080 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 244 └─[ConfigurationCCGet] parameter #: 29 09:31:01.080 CNTRLR « [Node 015] parameter #61 has value: 1 09:31:01.081 CNTRLR » [Node 015] querying parameter #62 value... 09:31:01.084 SERIAL « [ACK] (0x06) 09:31:01.089 SERIAL « 0x0104011301e8 (6 bytes) 09:31:01.090 SERIAL » [ACK] (0x06) 09:31:01.091 DRIVER « [RES] [SendData] was sent: true 09:31:01.126 SERIAL « 0x01070013f40000041b (9 bytes) 09:31:01.127 SERIAL » [ACK] (0x06) 09:31:01.127 DRIVER « [REQ] [SendData] callback id: 244 transmit status: OK 09:31:01.175 SERIAL « 0x010b000400100570061d01008f (13 bytes) 09:31:01.181 CNTRLR [Node 016] [~] [Configuration] 29: 0 => 0 09:31:01.182 SERIAL » [ACK] (0x06) 09:31:01.183 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 29 value size: 1 value: 0 09:31:01.186 SERIAL » 0x010a00130c0370051f25f553 (12 bytes) 09:31:01.186 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 245 └─[ConfigurationCCGet] parameter #: 31 09:31:01.190 CNTRLR « [Node 016] parameter #29 has value: 0 09:31:01.190 CNTRLR » [Node 016] querying parameter #30 value... 09:31:01.193 SERIAL « [ACK] (0x06) 09:31:01.199 SERIAL « 0x0104011301e8 (6 bytes) 09:31:01.199 SERIAL » [ACK] (0x06) 09:31:01.200 DRIVER « [RES] [SendData] was sent: true 09:31:01.302 SERIAL « 0x01070013f500000b15 (9 bytes) 09:31:01.302 SERIAL » [ACK] (0x06) 09:31:01.303 DRIVER « [REQ] [SendData] callback id: 245 transmit status: OK 09:31:01.356 SERIAL « 0x010b0004000c0570061f010091 (13 bytes) 09:31:01.361 CNTRLR [Node 012] [~] [Configuration] 31: 0 => 0 09:31:01.362 SERIAL » [ACK] (0x06) 09:31:01.363 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 0 09:31:01.372 SERIAL » 0x010a00130d0370052a25f664 (12 bytes) 09:31:01.372 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 246 └─[ConfigurationCCGet] parameter #: 42 09:31:01.373 CNTRLR « [Node 012] parameter #31 has value: 0 09:31:01.373 CNTRLR » [Node 012] querying parameter #32 value... 09:31:01.376 SERIAL « [ACK] (0x06) 09:31:01.382 SERIAL « 0x0104011301e8 (6 bytes) 09:31:01.382 SERIAL » [ACK] (0x06) 09:31:01.383 DRIVER « [RES] [SendData] was sent: true 09:31:01.446 SERIAL « 0x01070013f60000071a (9 bytes) 09:31:01.446 SERIAL » [ACK] (0x06) 09:31:01.447 DRIVER « [REQ] [SendData] callback id: 246 transmit status: OK 09:31:01.457 SERIAL « 0x010c0004000d0670062a020e10bc (14 bytes) 09:31:01.462 CNTRLR [Node 013] [~] [Configuration] 42: 3600 => 3600 09:31:01.463 SERIAL » [ACK] (0x06) 09:31:01.464 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 3600 09:31:01.467 SERIAL » 0x010a00130e0370052a25f766 (12 bytes) 09:31:01.468 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 247 └─[ConfigurationCCGet] parameter #: 42 09:31:01.468 CNTRLR « [Node 013] parameter #42 has value: 3600 09:31:01.468 CNTRLR » [Node 013] querying parameter #43 value... 09:31:01.471 SERIAL « [ACK] (0x06) 09:31:01.477 SERIAL « 0x0104011301e8 (6 bytes) 09:31:01.477 SERIAL » [ACK] (0x06) 09:31:01.478 DRIVER « [RES] [SendData] was sent: true 09:31:01.493 SERIAL « 0x01070013f70000021e (9 bytes) 09:31:01.493 SERIAL » [ACK] (0x06) 09:31:01.494 DRIVER « [REQ] [SendData] callback id: 247 transmit status: OK 09:31:01.504 SERIAL « 0x010c0004000e0670062a020e10bf (14 bytes) 09:31:01.514 CNTRLR [Node 014] [~] [Configuration] 42: 3600 => 3600 09:31:01.515 SERIAL » [ACK] (0x06) 09:31:01.516 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 3600 09:31:01.519 SERIAL » 0x010a00130f0370053e25f87c (12 bytes) 09:31:01.519 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 248 └─[ConfigurationCCGet] parameter #: 62 09:31:01.520 CNTRLR « [Node 014] parameter #42 has value: 3600 09:31:01.520 CNTRLR » [Node 014] querying parameter #43 value... 09:31:01.524 SERIAL « [ACK] (0x06) 09:31:01.528 SERIAL « 0x0104011301e8 (6 bytes) 09:31:01.529 SERIAL » [ACK] (0x06) 09:31:01.530 DRIVER « [RES] [SendData] was sent: true 09:31:01.545 SERIAL « 0x01070013f800000211 (9 bytes) 09:31:01.545 SERIAL » [ACK] (0x06) 09:31:01.546 DRIVER « [REQ] [SendData] callback id: 248 transmit status: OK 09:31:01.555 SERIAL « 0x010b0004000f0570063e0108bb (13 bytes) 09:31:01.560 CNTRLR [Node 015] [~] [Configuration] 62: 8 => 8 09:31:01.561 SERIAL » [ACK] (0x06) 09:31:01.562 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 62 value size: 1 value: 8 09:31:01.565 SERIAL » 0x010a0013100370051e25f942 (12 bytes) 09:31:01.566 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 249 └─[ConfigurationCCGet] parameter #: 30 09:31:01.566 CNTRLR « [Node 015] parameter #62 has value: 8 09:31:01.566 CNTRLR » [Node 015] querying parameter #63 value... 09:31:01.569 SERIAL « [ACK] (0x06) 09:31:01.575 SERIAL « 0x0104011301e8 (6 bytes) 09:31:01.575 SERIAL » [ACK] (0x06) 09:31:01.576 DRIVER « [RES] [SendData] was sent: true 09:31:01.612 SERIAL « 0x01070013f900000517 (9 bytes) 09:31:01.612 SERIAL » [ACK] (0x06) 09:31:01.613 DRIVER « [REQ] [SendData] callback id: 249 transmit status: OK 09:31:01.659 SERIAL « 0x010b000400100570061e01028e (13 bytes) 09:31:01.665 CNTRLR [Node 016] [~] [Configuration] 30: 2 => 2 09:31:01.669 SERIAL » [ACK] (0x06) 09:31:01.671 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 2 09:31:01.674 SERIAL » 0x010a00130c0370052025fa63 (12 bytes) 09:31:01.675 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 250 └─[ConfigurationCCGet] parameter #: 32 09:31:01.675 CNTRLR « [Node 016] parameter #30 has value: 2 09:31:01.675 CNTRLR » [Node 016] querying parameter #31 value... 09:31:01.679 SERIAL « [ACK] (0x06) 09:31:01.683 SERIAL « 0x0104011301e8 (6 bytes) 09:31:01.683 SERIAL » [ACK] (0x06) 09:31:01.684 DRIVER « [RES] [SendData] was sent: true 09:31:01.792 SERIAL « 0x01070013fa00000c1d (9 bytes) 09:31:01.792 SERIAL » [ACK] (0x06) 09:31:01.793 DRIVER « [REQ] [SendData] callback id: 250 transmit status: OK 09:31:01.846 SERIAL « 0x010b0004000c057006200101af (13 bytes) 09:31:01.854 CNTRLR [Node 012] [~] [Configuration] 32: 1 => 1 09:31:01.856 SERIAL » [ACK] (0x06) 09:31:01.857 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 1 value: 1 09:31:01.863 SERIAL » 0x010a00130d0370052b25fb68 (12 bytes) 09:31:01.863 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 251 └─[ConfigurationCCGet] parameter #: 43 09:31:01.864 CNTRLR « [Node 012] parameter #32 has value: 1 09:31:01.864 CNTRLR » [Node 012] querying parameter #33 value... 09:31:01.870 SERIAL « [ACK] (0x06) 09:31:01.895 SERIAL « 0x0104011301e8 (6 bytes) 09:31:01.895 SERIAL » [ACK] (0x06) 09:31:01.899 DRIVER « [RES] [SendData] was sent: true 09:31:01.937 SERIAL « 0x01070013fb00000717 (9 bytes) 09:31:01.937 SERIAL » [ACK] (0x06) 09:31:01.938 DRIVER « [REQ] [SendData] callback id: 251 transmit status: OK 09:31:01.947 SERIAL « 0x010b0004000d0570062b010aae (13 bytes) 09:31:01.956 CNTRLR [Node 013] [~] [Configuration] 43: 10 => 10 09:31:01.957 SERIAL » [ACK] (0x06) 09:31:01.958 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 10 09:31:01.962 SERIAL » 0x010a00130e0370052b25fc6c (12 bytes) 09:31:01.962 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 252 └─[ConfigurationCCGet] parameter #: 43 09:31:01.962 CNTRLR « [Node 013] parameter #43 has value: 10 09:31:01.963 CNTRLR » [Node 013] querying parameter #44 value... 09:31:01.966 SERIAL « [ACK] (0x06) 09:31:01.971 SERIAL « 0x0104011301e8 (6 bytes) 09:31:01.972 SERIAL » [ACK] (0x06) 09:31:01.973 DRIVER « [RES] [SendData] was sent: true 09:31:01.987 SERIAL « 0x01070013fc00000215 (9 bytes) 09:31:01.987 SERIAL » [ACK] (0x06) 09:31:01.988 DRIVER « [REQ] [SendData] callback id: 252 transmit status: OK 09:31:01.998 SERIAL « 0x010b0004000e0570062b010aad (13 bytes) 09:31:02.003 CNTRLR [Node 014] [~] [Configuration] 43: 10 => 10 09:31:02.004 SERIAL » [ACK] (0x06) 09:31:02.005 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 10 09:31:02.010 SERIAL » 0x010a00130f0370053f25fd78 (12 bytes) 09:31:02.011 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 253 └─[ConfigurationCCGet] parameter #: 63 09:31:02.011 CNTRLR « [Node 014] parameter #43 has value: 10 09:31:02.011 CNTRLR » [Node 014] querying parameter #44 value... 09:31:02.015 SERIAL « [ACK] (0x06) 09:31:02.020 SERIAL « 0x0104011301e8 (6 bytes) 09:31:02.020 SERIAL » [ACK] (0x06) 09:31:02.021 DRIVER « [RES] [SendData] was sent: true 09:31:02.036 SERIAL « 0x01070013fd00000214 (9 bytes) 09:31:02.036 SERIAL » [ACK] (0x06) 09:31:02.037 DRIVER « [REQ] [SendData] callback id: 253 transmit status: OK 09:31:02.047 SERIAL « 0x010b0004000f0570063f0101b3 (13 bytes) 09:31:02.052 CNTRLR [Node 015] [~] [Configuration] 63: 1 => 1 09:31:02.053 SERIAL » [ACK] (0x06) 09:31:02.054 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 63 value size: 1 value: 1 09:31:02.057 SERIAL » 0x010a0013100370051f25fe44 (12 bytes) 09:31:02.057 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 254 └─[ConfigurationCCGet] parameter #: 31 09:31:02.057 CNTRLR « [Node 015] parameter #63 has value: 1 09:31:02.058 CNTRLR » [Node 015] querying parameter #70 value... 09:31:02.061 SERIAL « [ACK] (0x06) 09:31:02.083 SERIAL « 0x0104011301e8 (6 bytes) 09:31:02.083 SERIAL » [ACK] (0x06) 09:31:02.085 DRIVER « [RES] [SendData] was sent: true 09:31:02.104 SERIAL « 0x01070013fe00000411 (9 bytes) 09:31:02.104 SERIAL » [ACK] (0x06) 09:31:02.105 DRIVER « [REQ] [SendData] callback id: 254 transmit status: OK 09:31:02.152 SERIAL « 0x010b000400100570061f01008d (13 bytes) 09:31:02.157 CNTRLR [Node 016] [~] [Configuration] 31: 0 => 0 09:31:02.158 SERIAL » [ACK] (0x06) 09:31:02.159 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 0 09:31:02.162 SERIAL » 0x010a00130c0370052125ff67 (12 bytes) 09:31:02.163 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 255 └─[ConfigurationCCGet] parameter #: 33 09:31:02.163 CNTRLR « [Node 016] parameter #31 has value: 0 09:31:02.163 CNTRLR » [Node 016] querying parameter #32 value... 09:31:02.172 SERIAL « [ACK] (0x06) 09:31:02.175 SERIAL « 0x0104011301e8 (6 bytes) 09:31:02.175 SERIAL » [ACK] (0x06) 09:31:02.182 DRIVER « [RES] [SendData] was sent: true 09:31:02.282 SERIAL « 0x01070013ff00000c18 (9 bytes) 09:31:02.282 SERIAL » [ACK] (0x06) 09:31:02.283 DRIVER « [REQ] [SendData] callback id: 255 transmit status: OK 09:31:02.334 SERIAL « 0x010b0004000c057006210101ae (13 bytes) 09:31:02.342 CNTRLR [Node 012] [~] [Configuration] 33: 1 => 1 09:31:02.343 SERIAL » [ACK] (0x06) 09:31:02.344 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 1 value: 1 09:31:02.347 SERIAL » 0x010a00130d0370052c250195 (12 bytes) 09:31:02.347 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 1 └─[ConfigurationCCGet] parameter #: 44 09:31:02.348 CNTRLR « [Node 012] parameter #33 has value: 1 09:31:02.348 CNTRLR » [Node 012] querying parameter #35 value... 09:31:02.361 SERIAL « [ACK] (0x06) 09:31:02.362 SERIAL « 0x0104011301e8 (6 bytes) 09:31:02.363 SERIAL » [ACK] (0x06) 09:31:02.365 DRIVER « [RES] [SendData] was sent: true 09:31:02.416 SERIAL « 0x0107001301000006ec (9 bytes) 09:31:02.417 SERIAL » [ACK] (0x06) 09:31:02.417 DRIVER « [REQ] [SendData] callback id: 1 transmit status: OK 09:31:02.427 SERIAL « 0x010b0004000d0570062c0100a3 (13 bytes) 09:31:02.432 CNTRLR [Node 013] [~] [Configuration] 44: 0 => 0 09:31:02.434 SERIAL » [ACK] (0x06) 09:31:02.434 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 44 value size: 1 value: 0 09:31:02.437 SERIAL » 0x010a00130e0370052c250295 (12 bytes) 09:31:02.438 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 2 └─[ConfigurationCCGet] parameter #: 44 09:31:02.438 CNTRLR « [Node 013] parameter #44 has value: 0 09:31:02.438 CNTRLR » [Node 013] querying parameter #50 value... 09:31:02.447 SERIAL « [ACK] (0x06) 09:31:02.448 SERIAL « 0x0104011301e8 (6 bytes) 09:31:02.449 SERIAL » [ACK] (0x06) 09:31:02.449 DRIVER « [RES] [SendData] was sent: true 09:31:02.463 SERIAL « 0x0107001302000002eb (9 bytes) 09:31:02.463 SERIAL » [ACK] (0x06) 09:31:02.464 DRIVER « [REQ] [SendData] callback id: 2 transmit status: OK 09:31:02.474 SERIAL « 0x010b0004000e0570062c0100a0 (13 bytes) 09:31:02.479 CNTRLR [Node 014] [~] [Configuration] 44: 0 => 0 09:31:02.480 SERIAL » [ACK] (0x06) 09:31:02.480 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 44 value size: 1 value: 0 09:31:02.483 SERIAL » 0x010a00130f037005462503ff (12 bytes) 09:31:02.484 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 3 └─[ConfigurationCCGet] parameter #: 70 09:31:02.484 CNTRLR « [Node 014] parameter #44 has value: 0 09:31:02.484 CNTRLR » [Node 014] querying parameter #50 value... 09:31:02.488 SERIAL « [ACK] (0x06) 09:31:02.493 SERIAL « 0x0104011301e8 (6 bytes) 09:31:02.493 SERIAL » [ACK] (0x06) 09:31:02.494 DRIVER « [RES] [SendData] was sent: true 09:31:02.509 SERIAL « 0x0107001303000002ea (9 bytes) 09:31:02.509 SERIAL » [ACK] (0x06) 09:31:02.510 DRIVER « [REQ] [SendData] callback id: 3 transmit status: OK 09:31:02.520 SERIAL « 0x010c0004000f0670064602ffffcc (14 bytes) 09:31:02.525 CNTRLR [Node 015] [~] [Configuration] 70: 65535 => 65535 09:31:02.526 SERIAL » [ACK] (0x06) 09:31:02.527 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 70 value size: 2 value: 65535 09:31:02.530 SERIAL » 0x010a00131003700520250481 (12 bytes) 09:31:02.531 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 4 └─[ConfigurationCCGet] parameter #: 32 09:31:02.531 CNTRLR « [Node 015] parameter #70 has value: 65535 09:31:02.531 CNTRLR [Node 015] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 09:31:02.581 SERIAL « [ACK] (0x06) 09:31:02.586 SERIAL « 0x0104011301e8 (6 bytes) 09:31:02.586 SERIAL » [ACK] (0x06) 09:31:02.593 DRIVER « [RES] [SendData] was sent: true 09:31:02.612 CNTRLR [Node 015] MultiChannelAssociationCC: doing a partial interview... 09:31:02.612 CNTRLR » [Node 015] querying multi channel association group #1... 09:31:02.637 SERIAL « 0x0107001304000004eb (9 bytes) 09:31:02.638 SERIAL » [ACK] (0x06) 09:31:02.641 DRIVER « [REQ] [SendData] callback id: 4 transmit status: OK 09:31:02.657 SERIAL « 0x010b00040010057006200101b3 (13 bytes) 09:31:02.668 CNTRLR [Node 016] [~] [Configuration] 32: 1 => 1 09:31:02.670 SERIAL » [ACK] (0x06) 09:31:02.672 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 1 value: 1 09:31:02.677 SERIAL » 0x010a00130f038e0201250547 (12 bytes) 09:31:02.678 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 5 └─[MultiChannelAssociationCCGet] group id: 1 09:31:02.678 CNTRLR « [Node 016] parameter #32 has value: 1 09:31:02.678 CNTRLR » [Node 016] querying parameter #33 value... 09:31:02.691 SERIAL « [ACK] (0x06) 09:31:02.693 SERIAL « 0x0104011301e8 (6 bytes) 09:31:02.693 SERIAL » [ACK] (0x06) 09:31:02.695 DRIVER « [RES] [SendData] was sent: true 09:31:02.706 SERIAL « 0x0107001305000002ec (9 bytes) 09:31:02.707 SERIAL » [ACK] (0x06) 09:31:02.707 DRIVER « [REQ] [SendData] callback id: 5 transmit status: OK 09:31:02.717 SERIAL « 0x010b0004000f058e0301050073 (13 bytes) 09:31:02.718 SERIAL » [ACK] (0x06) 09:31:02.720 CNTRLR [Node 015] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 09:31:02.722 CNTRLR [Node 015] [~] [Multi Channel Association] nodeIds[1]: => 09:31:02.723 CNTRLR [Node 015] [~] [Multi Channel Association] endpoints[1]: => 09:31:02.725 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: endpoints: 09:31:02.730 SERIAL » 0x010a00130c0370052325069c (12 bytes) 09:31:02.731 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 6 └─[ConfigurationCCGet] parameter #: 35 09:31:02.732 CNTRLR « [Node 015] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 09:31:02.732 CNTRLR » [Node 015] querying multi channel association group #2... 09:31:02.743 SERIAL « [ACK] (0x06) 09:31:02.744 SERIAL « 0x0104011301e8 (6 bytes) 09:31:02.745 SERIAL » [ACK] (0x06) 09:31:02.746 DRIVER « [RES] [SendData] was sent: true 09:31:02.802 SERIAL « 0x0107001306000007ea (9 bytes) 09:31:02.802 SERIAL » [ACK] (0x06) 09:31:02.803 DRIVER « [REQ] [SendData] callback id: 6 transmit status: OK 09:31:02.856 SERIAL « 0x010b0004000c057006230101ac (13 bytes) 09:31:02.862 CNTRLR [Node 012] [~] [Configuration] 35: 1 => 1 09:31:02.863 SERIAL » [ACK] (0x06) 09:31:02.863 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 1 09:31:02.868 SERIAL » 0x010a00130f038e0202250746 (12 bytes) 09:31:02.868 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 7 └─[MultiChannelAssociationCCGet] group id: 2 09:31:02.868 CNTRLR « [Node 012] parameter #35 has value: 1 09:31:02.869 CNTRLR » [Node 012] querying parameter #40 value... 09:31:02.872 SERIAL « [ACK] (0x06) 09:31:02.879 SERIAL « 0x0104011301e8 (6 bytes) 09:31:02.880 SERIAL » [ACK] (0x06) 09:31:02.881 DRIVER « [RES] [SendData] was sent: true 09:31:02.946 SERIAL « 0x0107001307000007eb (9 bytes) 09:31:02.946 SERIAL » [ACK] (0x06) 09:31:02.947 DRIVER « [REQ] [SendData] callback id: 7 transmit status: OK 09:31:02.957 SERIAL « 0x010b0004000f058e0302050070 (13 bytes) 09:31:02.957 SERIAL » [ACK] (0x06) 09:31:02.958 CNTRLR [Node 015] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 09:31:02.959 CNTRLR [Node 015] [~] [Multi Channel Association] nodeIds[2]: => 09:31:02.960 CNTRLR [Node 015] [~] [Multi Channel Association] endpoints[2]: => 09:31:02.961 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 09:31:02.964 SERIAL » 0x010a00130d03700532250882 (12 bytes) 09:31:02.964 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 8 └─[ConfigurationCCGet] parameter #: 50 09:31:02.965 CNTRLR « [Node 015] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 09:31:02.965 CNTRLR » [Node 015] querying additional non-multi-channel association groups... 09:31:02.965 CNTRLR » [Node 015] querying association group #3... 09:31:02.968 SERIAL « [ACK] (0x06) 09:31:02.972 SERIAL « 0x0104011301e8 (6 bytes) 09:31:02.973 SERIAL » [ACK] (0x06) 09:31:02.973 DRIVER « [RES] [SendData] was sent: true 09:31:02.989 SERIAL « 0x0107001308000002e1 (9 bytes) 09:31:02.990 SERIAL » [ACK] (0x06) 09:31:02.991 DRIVER « [REQ] [SendData] callback id: 8 transmit status: OK 09:31:03.000 SERIAL « 0x010b0004000d057006320100bd (13 bytes) 09:31:03.005 CNTRLR [Node 013] [~] [Configuration] 50: 0 => 0 09:31:03.006 SERIAL » [ACK] (0x06) 09:31:03.007 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 0 09:31:03.010 SERIAL » 0x010a00130f03850203250942 (12 bytes) 09:31:03.011 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 9 └─[AssociationCCGet] group id: 3 09:31:03.011 CNTRLR « [Node 013] parameter #50 has value: 0 09:31:03.011 CNTRLR [Node 013] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 09:31:03.061 SERIAL « [ACK] (0x06) 09:31:03.064 SERIAL « 0x0104011301e8 (6 bytes) 09:31:03.064 SERIAL » [ACK] (0x06) 09:31:03.066 DRIVER « [RES] [SendData] was sent: true 09:31:03.068 SERIAL « 0x0107001309000002e0 (9 bytes) 09:31:03.068 SERIAL » [ACK] (0x06) 09:31:03.070 CNTRLR [Node 013] ProtectionCC: doing a partial interview... 09:31:03.070 CNTRLR » [Node 013] querying protection status... 09:31:03.074 DRIVER « [REQ] [SendData] callback id: 9 transmit status: OK 09:31:03.078 SERIAL « 0x010c0004000f068503030100017b (14 bytes) 09:31:03.079 SERIAL » [ACK] (0x06) 09:31:03.080 CNTRLR [Node 015] [~] [Association] maxNodes[3]: 1 => 1 [internal] 09:31:03.080 CNTRLR [Node 015] [~] [Association] nodeIds[3]: 1 => 1 [internal] 09:31:03.081 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 09:31:03.084 SERIAL » 0x010a00130e03700532250a83 (12 bytes) 09:31:03.084 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 10 └─[ConfigurationCCGet] parameter #: 50 09:31:03.085 CNTRLR « [Node 015] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 09:31:03.086 CNTRLR [Node 015] [~] [Association] hasLifeline: true => true [internal] 09:31:03.086 CNTRLR [Node 015] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 09:31:03.086 CNTRLR [Node 015] Interview stage completed: CommandClasses 09:31:03.087 CNTRLR [Node 015] Interview stage completed: OverwriteConfig 09:31:03.087 CNTRLR » [Node 015] requesting node neighbors... 09:31:03.091 SERIAL « [ACK] (0x06) 09:31:03.092 SERIAL « 0x0104011301e8 (6 bytes) 09:31:03.093 SERIAL » [ACK] (0x06) 09:31:03.094 DRIVER « [RES] [SendData] was sent: true 09:31:03.110 SERIAL « 0x010700130a000002e3 (9 bytes) 09:31:03.110 SERIAL » [ACK] (0x06) 09:31:03.111 DRIVER « [REQ] [SendData] callback id: 10 transmit status: OK 09:31:03.120 SERIAL « 0x010b0004000e057006320100be (13 bytes) 09:31:03.126 CNTRLR [Node 014] [~] [Configuration] 50: 0 => 0 09:31:03.127 SERIAL » [ACK] (0x06) 09:31:03.128 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 0 09:31:03.131 SERIAL » 0x010700800f00000077 (9 bytes) 09:31:03.131 DRIVER » [Node 015] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:31:03.132 CNTRLR « [Node 014] parameter #50 has value: 0 09:31:03.132 CNTRLR [Node 014] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 09:31:03.132 CNTRLR [Node 014] ProtectionCC: doing a partial interview... 09:31:03.133 CNTRLR » [Node 014] querying protection status... 09:31:03.136 SERIAL « [ACK] (0x06) 09:31:03.137 SERIAL « 0x0120018065b9fd6b0700000000000000000000000000000000000000000000000 (34 bytes) 013 09:31:03.137 SERIAL » [ACK] (0x06) 09:31:03.138 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 9, 12, 13, 14, 16, 17, 19, 20, 21, 22, 23, 24, 25, 26, 28, 30, 31, 33, 34, 35 09:31:03.144 SERIAL » 0x010a00131003700521250b8f (12 bytes) 09:31:03.144 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 11 └─[ConfigurationCCGet] parameter #: 33 09:31:03.145 CNTRLR « [Node 015] node neighbors received: 1, 3, 6, 7, 9, 12, 13, 14, 16, 17, 19, 2 0, 21, 22, 23, 24, 25, 26, 28, 30, 31, 33, 34, 35 09:31:03.145 CNTRLR [Node 015] Interview stage completed: Neighbors 09:31:03.145 CNTRLR [Node 015] Interview completed 09:31:03.148 SERIAL « [ACK] (0x06) 09:31:03.152 SERIAL « 0x0104011301e8 (6 bytes) 09:31:03.153 SERIAL » [ACK] (0x06) 09:31:03.153 DRIVER « [RES] [SendData] was sent: true 09:31:03.191 SERIAL « 0x010700130b000005e5 (9 bytes) 09:31:03.191 SERIAL » [ACK] (0x06) 09:31:03.191 DRIVER « [REQ] [SendData] callback id: 11 transmit status: OK 09:31:03.269 SERIAL « 0x010b00040010057006210101b2 (13 bytes) 09:31:03.274 CNTRLR [Node 016] [~] [Configuration] 33: 1 => 1 09:31:03.275 SERIAL » [ACK] (0x06) 09:31:03.279 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 1 value: 1 09:31:03.282 SERIAL » 0x010a00130c03700528250c9d (12 bytes) 09:31:03.283 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 12 └─[ConfigurationCCGet] parameter #: 40 09:31:03.283 CNTRLR « [Node 016] parameter #33 has value: 1 09:31:03.284 CNTRLR » [Node 016] querying parameter #35 value... 09:31:03.287 SERIAL « [ACK] (0x06) 09:31:03.291 SERIAL « 0x0104011301e8 (6 bytes) 09:31:03.291 SERIAL » [ACK] (0x06) 09:31:03.292 DRIVER « [RES] [SendData] was sent: true 09:31:03.371 SERIAL « 0x010700130c000009ee (9 bytes) 09:31:03.372 SERIAL » [ACK] (0x06) 09:31:03.372 DRIVER « [REQ] [SendData] callback id: 12 transmit status: OK 09:31:03.426 SERIAL « 0x010b0004000c05700628010aac (13 bytes) 09:31:03.431 CNTRLR [Node 012] [~] [Configuration] 40: 10 => 10 09:31:03.432 SERIAL » [ACK] (0x06) 09:31:03.433 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 10 09:31:03.437 SERIAL » 0x010900130d027502250db5 (11 bytes) 09:31:03.437 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 13 └─[ProtectionCCGet] 09:31:03.438 CNTRLR « [Node 012] parameter #40 has value: 10 09:31:03.438 CNTRLR » [Node 012] querying parameter #42 value... 09:31:03.441 SERIAL « [ACK] (0x06) 09:31:03.447 SERIAL « 0x0104011301e8 (6 bytes) 09:31:03.447 SERIAL » [ACK] (0x06) 09:31:03.448 DRIVER « [RES] [SendData] was sent: true 09:31:03.516 SERIAL « 0x010700130d000007e1 (9 bytes) 09:31:03.517 SERIAL » [ACK] (0x06) 09:31:03.518 DRIVER « [REQ] [SendData] callback id: 13 transmit status: OK 09:31:03.527 SERIAL « 0x010a0004000d04750300008e (12 bytes) 09:31:03.528 CNTRLR [Node 013] [~] [Protection] local: 0 => 0 [Endpoint 0] 09:31:03.529 CNTRLR [Node 013] [~] [Protection] rf: 0 => 0 [Endpoint 0] 09:31:03.530 SERIAL » [ACK] (0x06) 09:31:03.532 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 09:31:03.536 SERIAL » 0x010900130e027502250eb5 (11 bytes) 09:31:03.537 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 14 └─[ProtectionCCGet] 09:31:03.538 CNTRLR « [Node 013] received protection status: local: Unprotected rf Unprotected 09:31:03.555 CNTRLR [Node 013] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 09:31:03.590 SERIAL « [ACK] (0x06) 09:31:03.591 SERIAL « 0x0104011301e8 (6 bytes) 09:31:03.592 SERIAL » [ACK] (0x06) 09:31:03.593 DRIVER « [RES] [SendData] was sent: true 09:31:03.595 SERIAL « 0x010700130e000002e7 (9 bytes) 09:31:03.595 SERIAL » [ACK] (0x06) 09:31:03.596 DRIVER « [REQ] [SendData] callback id: 14 transmit status: OK 09:31:03.599 SERIAL « 0x010a0004000e04750300008d (12 bytes) 09:31:03.599 CNTRLR [Node 014] [~] [Protection] local: 0 => 0 [Endpoint 0] 09:31:03.600 CNTRLR [Node 014] [~] [Protection] rf: 0 => 0 [Endpoint 0] 09:31:03.601 SERIAL » [ACK] (0x06) 09:31:03.602 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 09:31:03.606 SERIAL » 0x010a00131003700523250f89 (12 bytes) 09:31:03.606 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 15 └─[ConfigurationCCGet] parameter #: 35 09:31:03.607 CNTRLR « [Node 014] received protection status: local: Unprotected rf Unprotected 09:31:03.607 CNTRLR [Node 014] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 09:31:03.620 CNTRLR [Node 014] FibaroVenetianBlindCC: doing a partial interview... 09:31:03.621 CNTRLR » [Node 014] Requesting venetian blind position and tilt... 09:31:03.638 SERIAL « [ACK] (0x06) 09:31:03.639 SERIAL « 0x0104011301e8 (6 bytes) 09:31:03.639 SERIAL » [ACK] (0x06) 09:31:03.640 DRIVER « [RES] [SendData] was sent: true 09:31:03.653 SERIAL « 0x010700130f000005e1 (9 bytes) 09:31:03.653 SERIAL » [ACK] (0x06) 09:31:03.654 DRIVER « [REQ] [SendData] callback id: 15 transmit status: OK 09:31:03.702 SERIAL « 0x010b00040010057006230101b0 (13 bytes) 09:31:03.707 CNTRLR [Node 016] [~] [Configuration] 35: 1 => 1 09:31:03.708 SERIAL » [ACK] (0x06) 09:31:03.709 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 1 09:31:03.713 SERIAL » 0x010c00130e0591010f2602251065 (14 bytes) 09:31:03.713 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[FibaroVenetianBlindCCGet] payload: 0x0f2602 09:31:03.714 CNTRLR « [Node 016] parameter #35 has value: 1 09:31:03.714 CNTRLR » [Node 016] querying parameter #40 value... 09:31:03.717 SERIAL « [ACK] (0x06) 09:31:03.722 SERIAL « 0x0104011301e8 (6 bytes) 09:31:03.723 SERIAL » [ACK] (0x06) 09:31:03.723 DRIVER « [RES] [SendData] was sent: true 09:31:03.787 SERIAL « 0x0107001310000007fc (9 bytes) 09:31:03.787 SERIAL » [ACK] (0x06) 09:31:03.789 DRIVER « [REQ] [SendData] callback id: 16 transmit status: OK 09:31:03.802 SERIAL « 0x010e0004000e0891010f26030201004a (16 bytes) 09:31:03.805 CNTRLR [Node 014] [Manufacturer Proprietary] fibaro[venetianBlindsPositi [Endpoint 0] on]: metadata updated 09:31:03.806 CNTRLR [Node 014] [~] [Manufacturer Proprietary] fibaro[venetianBlindsPo [Endpoint 0] sition]: 1 => 1 09:31:03.807 SERIAL » [ACK] (0x06) 09:31:03.809 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[FibaroVenetianBlindCCReport] position: 1 09:31:03.812 SERIAL » 0x010a00130c0370052a251182 (12 bytes) 09:31:03.813 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 17 └─[ConfigurationCCGet] parameter #: 42 09:31:03.813 CNTRLR « [Node 014] received venetian blind state: position: 1 tilt: undefined 09:31:03.814 CNTRLR [Node 014] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 09:31:03.814 CNTRLR [Node 014] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 09:31:03.814 CNTRLR [Node 014] MultiChannelAssociationCC: doing a partial interview... 09:31:03.815 CNTRLR » [Node 014] querying multi channel association group #1... 09:31:03.817 SERIAL « [ACK] (0x06) 09:31:03.821 SERIAL « 0x0104011301e8 (6 bytes) 09:31:03.821 SERIAL » [ACK] (0x06) 09:31:03.822 DRIVER « [RES] [SendData] was sent: true 09:31:03.884 SERIAL « 0x0107001311000007fd (9 bytes) 09:31:03.884 SERIAL » [ACK] (0x06) 09:31:03.885 DRIVER « [REQ] [SendData] callback id: 17 transmit status: OK 09:31:03.939 SERIAL « 0x010c0004000c0670062a020e10bd (14 bytes) 09:31:03.944 CNTRLR [Node 012] [~] [Configuration] 42: 3600 => 3600 09:31:03.945 SERIAL » [ACK] (0x06) 09:31:03.945 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 3600 09:31:03.949 SERIAL » 0x010a00130e038e0201251251 (12 bytes) 09:31:03.949 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 18 └─[MultiChannelAssociationCCGet] group id: 1 09:31:03.949 CNTRLR « [Node 012] parameter #42 has value: 3600 09:31:03.950 CNTRLR » [Node 012] querying parameter #43 value... 09:31:03.953 SERIAL « [ACK] (0x06) 09:31:03.957 SERIAL « 0x0104011301e8 (6 bytes) 09:31:03.957 SERIAL » [ACK] (0x06) 09:31:03.959 DRIVER « [RES] [SendData] was sent: true 09:31:04.026 SERIAL « 0x0107001312000007fe (9 bytes) 09:31:04.027 SERIAL » [ACK] (0x06) 09:31:04.027 DRIVER « [REQ] [SendData] callback id: 18 transmit status: OK 09:31:04.037 SERIAL « 0x010b0004000e058e0301070070 (13 bytes) 09:31:04.038 SERIAL » [ACK] (0x06) 09:31:04.038 CNTRLR [Node 014] [~] [Multi Channel Association] maxNodes[1]: 7 => 7 09:31:04.039 CNTRLR [Node 014] [~] [Multi Channel Association] nodeIds[1]: => 09:31:04.040 CNTRLR [Node 014] [~] [Multi Channel Association] endpoints[1]: => 09:31:04.041 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 7 node ids: endpoints: 09:31:04.048 SERIAL » 0x010a0013100370052825139e (12 bytes) 09:31:04.049 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 19 └─[ConfigurationCCGet] parameter #: 40 09:31:04.049 CNTRLR « [Node 014] received information for multi channel association group #1: maximum # of nodes: 7 currently assigned nodes: currently assigned endpoints: 09:31:04.049 CNTRLR » [Node 014] querying multi channel association group #2... 09:31:04.053 SERIAL « [ACK] (0x06) 09:31:04.057 SERIAL « 0x0104011301e8 (6 bytes) 09:31:04.057 SERIAL » [ACK] (0x06) 09:31:04.058 DRIVER « [RES] [SendData] was sent: true 09:31:04.095 SERIAL « 0x0107001313000004fc (9 bytes) 09:31:04.095 SERIAL » [ACK] (0x06) 09:31:04.096 DRIVER « [REQ] [SendData] callback id: 19 transmit status: OK 09:31:04.144 SERIAL « 0x010b0004001005700628010ab0 (13 bytes) 09:31:04.149 CNTRLR [Node 016] [~] [Configuration] 40: 10 => 10 09:31:04.150 SERIAL » [ACK] (0x06) 09:31:04.150 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 10 09:31:04.153 SERIAL » 0x010a00130e038e0202251454 (12 bytes) 09:31:04.154 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 20 └─[MultiChannelAssociationCCGet] group id: 2 09:31:04.154 CNTRLR « [Node 016] parameter #40 has value: 10 09:31:04.154 CNTRLR » [Node 016] querying parameter #42 value... 09:31:04.157 SERIAL « [ACK] (0x06) 09:31:04.163 SERIAL « 0x0104011301e8 (6 bytes) 09:31:04.164 SERIAL » [ACK] (0x06) 09:31:04.164 DRIVER « [RES] [SendData] was sent: true 09:31:04.236 SERIAL « 0x0107001314000008f7 (9 bytes) 09:31:04.236 SERIAL » [ACK] (0x06) 09:31:04.237 DRIVER « [REQ] [SendData] callback id: 20 transmit status: OK 09:31:04.247 SERIAL « 0x010b0004000e058e0302070073 (13 bytes) 09:31:04.247 SERIAL » [ACK] (0x06) 09:31:04.248 CNTRLR [Node 014] [~] [Multi Channel Association] maxNodes[2]: 7 => 7 09:31:04.249 CNTRLR [Node 014] [~] [Multi Channel Association] nodeIds[2]: => 09:31:04.250 CNTRLR [Node 014] [~] [Multi Channel Association] endpoints[2]: => 09:31:04.251 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 7 node ids: endpoints: 09:31:04.254 SERIAL » 0x010a00130c0370052b251587 (12 bytes) 09:31:04.254 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 21 └─[ConfigurationCCGet] parameter #: 43 09:31:04.255 CNTRLR « [Node 014] received information for multi channel association group #2: maximum # of nodes: 7 currently assigned nodes: currently assigned endpoints: 09:31:04.255 CNTRLR » [Node 014] querying additional non-multi-channel association groups... 09:31:04.255 CNTRLR » [Node 014] querying association group #3... 09:31:04.258 SERIAL « [ACK] (0x06) 09:31:04.262 SERIAL « 0x0104011301e8 (6 bytes) 09:31:04.263 SERIAL » [ACK] (0x06) 09:31:04.263 DRIVER « [RES] [SendData] was sent: true 09:31:04.326 SERIAL « 0x0107001315000007f9 (9 bytes) 09:31:04.326 SERIAL » [ACK] (0x06) 09:31:04.326 DRIVER « [REQ] [SendData] callback id: 21 transmit status: OK 09:31:04.378 SERIAL « 0x010b0004000c0570062b010aaf (13 bytes) 09:31:04.386 CNTRLR [Node 012] [~] [Configuration] 43: 10 => 10 09:31:04.388 SERIAL » [ACK] (0x06) 09:31:04.388 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 10 09:31:04.393 SERIAL » 0x010a00130e0385020325165c (12 bytes) 09:31:04.393 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 22 └─[AssociationCCGet] group id: 3 09:31:04.394 CNTRLR « [Node 012] parameter #43 has value: 10 09:31:04.394 CNTRLR » [Node 012] querying parameter #44 value... 09:31:04.399 SERIAL « [ACK] (0x06) 09:31:04.401 SERIAL « 0x0104011301e8 (6 bytes) 09:31:04.402 SERIAL » [ACK] (0x06) 09:31:04.403 DRIVER « [RES] [SendData] was sent: true 09:31:04.466 SERIAL « 0x0107001316000007fa (9 bytes) 09:31:04.467 SERIAL » [ACK] (0x06) 09:31:04.467 DRIVER « [REQ] [SendData] callback id: 22 transmit status: OK 09:31:04.477 SERIAL « 0x010c0004000e068503030100017a (14 bytes) 09:31:04.478 SERIAL » [ACK] (0x06) 09:31:04.480 CNTRLR [Node 014] [~] [Association] maxNodes[3]: 1 => 1 [internal] 09:31:04.480 CNTRLR [Node 014] [~] [Association] nodeIds[3]: 1 => 1 [internal] 09:31:04.481 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 09:31:04.486 SERIAL » 0x010a0013100370052a251798 (12 bytes) 09:31:04.487 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 23 └─[ConfigurationCCGet] parameter #: 42 09:31:04.487 CNTRLR « [Node 014] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 09:31:04.488 CNTRLR [Node 014] [~] [Association] hasLifeline: true => true [internal] 09:31:04.489 CNTRLR [Node 014] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 09:31:04.489 CNTRLR [Node 014] Interview stage completed: CommandClasses 09:31:04.489 CNTRLR [Node 014] Interview stage completed: OverwriteConfig 09:31:04.489 CNTRLR » [Node 014] requesting node neighbors... 09:31:04.493 SERIAL « [ACK] (0x06) 09:31:04.495 SERIAL « 0x0104011301e8 (6 bytes) 09:31:04.495 SERIAL » [ACK] (0x06) 09:31:04.496 DRIVER « [RES] [SendData] was sent: true 09:31:04.533 SERIAL « 0x0107001317000005f9 (9 bytes) 09:31:04.534 SERIAL » [ACK] (0x06) 09:31:04.535 DRIVER « [REQ] [SendData] callback id: 23 transmit status: OK 09:31:04.582 SERIAL « 0x010c000400100670062a020e10a1 (14 bytes) 09:31:04.593 CNTRLR [Node 016] [~] [Configuration] 42: 3600 => 3600 09:31:04.594 SERIAL » [ACK] (0x06) 09:31:04.599 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 3600 09:31:04.604 SERIAL » 0x010700800e00000076 (9 bytes) 09:31:04.605 DRIVER » [Node 014] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:31:04.606 CNTRLR « [Node 016] parameter #42 has value: 3600 09:31:04.606 CNTRLR » [Node 016] querying parameter #43 value... 09:31:04.619 CNTRLR [Node 013] FibaroVenetianBlindCC: doing a partial interview... 09:31:04.619 CNTRLR » [Node 013] Requesting venetian blind position and tilt... 09:31:04.623 SERIAL « [ACK] (0x06) 09:31:04.625 SERIAL « 0x0120018065d9fc7f0700000000000000000000000000000000000000000000000 (34 bytes) 066 09:31:04.626 SERIAL » [ACK] (0x06) 09:31:04.629 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 9, 12, 13, 15, 16, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 33, 34, 35 09:31:04.638 SERIAL » 0x010c00130d0591010f260225186e (14 bytes) 09:31:04.639 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 24 └─[FibaroVenetianBlindCCGet] payload: 0x0f2602 09:31:04.639 CNTRLR « [Node 014] node neighbors received: 1, 3, 6, 7, 9, 12, 13, 15, 16, 19, 20, 2 1, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 33, 34, 35 09:31:04.639 CNTRLR [Node 014] Interview stage completed: Neighbors 09:31:04.640 CNTRLR [Node 014] Interview completed 09:31:04.649 SERIAL « [ACK] (0x06) 09:31:04.651 SERIAL « 0x0104011301e8 (6 bytes) 09:31:04.651 SERIAL » [ACK] (0x06) 09:31:04.655 DRIVER « [RES] [SendData] was sent: true 09:31:04.667 SERIAL « 0x0107001318000002f1 (9 bytes) 09:31:04.667 SERIAL » [ACK] (0x06) 09:31:04.668 DRIVER « [REQ] [SendData] callback id: 24 transmit status: OK 09:31:04.678 SERIAL « 0x010e0004000d0891010f260302010049 (16 bytes) 09:31:04.680 CNTRLR [Node 013] [Manufacturer Proprietary] fibaro[venetianBlindsPositi [Endpoint 0] on]: metadata updated 09:31:04.681 CNTRLR [Node 013] [~] [Manufacturer Proprietary] fibaro[venetianBlindsPo [Endpoint 0] sition]: 1 => 1 09:31:04.682 SERIAL » [ACK] (0x06) 09:31:04.683 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[FibaroVenetianBlindCCReport] position: 1 09:31:04.690 SERIAL » 0x010a00130c0370052c25198c (12 bytes) 09:31:04.690 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 25 └─[ConfigurationCCGet] parameter #: 44 09:31:04.691 CNTRLR « [Node 013] received venetian blind state: position: 1 tilt: undefined 09:31:04.691 CNTRLR [Node 013] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 09:31:04.692 CNTRLR [Node 013] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 09:31:04.698 CNTRLR [Node 013] MultiChannelAssociationCC: doing a partial interview... 09:31:04.698 CNTRLR » [Node 013] querying multi channel association group #1... 09:31:04.704 SERIAL « [ACK] (0x06) 09:31:04.705 SERIAL « 0x0104011301e8 (6 bytes) 09:31:04.706 SERIAL » [ACK] (0x06) 09:31:04.710 DRIVER « [RES] [SendData] was sent: true 09:31:04.761 SERIAL « 0x0107001319000007f5 (9 bytes) 09:31:04.761 SERIAL » [ACK] (0x06) 09:31:04.762 DRIVER « [REQ] [SendData] callback id: 25 transmit status: OK 09:31:04.814 SERIAL « 0x010b0004000c0570062c0100a2 (13 bytes) 09:31:04.822 CNTRLR [Node 012] [~] [Configuration] 44: 0 => 0 09:31:04.823 SERIAL » [ACK] (0x06) 09:31:04.824 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 44 value size: 1 value: 0 09:31:04.829 SERIAL » 0x010a00130d038e0201251a5a (12 bytes) 09:31:04.829 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 26 └─[MultiChannelAssociationCCGet] group id: 1 09:31:04.833 CNTRLR « [Node 012] parameter #44 has value: 0 09:31:04.833 CNTRLR » [Node 012] querying parameter #50 value... 09:31:04.837 SERIAL « [ACK] (0x06) 09:31:04.839 SERIAL « 0x0104011301e8 (6 bytes) 09:31:04.839 SERIAL » [ACK] (0x06) 09:31:04.840 DRIVER « [RES] [SendData] was sent: true 09:31:04.897 SERIAL « 0x010700131a000006f7 (9 bytes) 09:31:04.897 SERIAL » [ACK] (0x06) 09:31:04.898 DRIVER « [REQ] [SendData] callback id: 26 transmit status: OK 09:31:04.907 SERIAL « 0x010b0004000d058e0301070073 (13 bytes) 09:31:04.908 SERIAL » [ACK] (0x06) 09:31:04.909 CNTRLR [Node 013] [~] [Multi Channel Association] maxNodes[1]: 7 => 7 09:31:04.910 CNTRLR [Node 013] [~] [Multi Channel Association] nodeIds[1]: => 09:31:04.912 CNTRLR [Node 013] [~] [Multi Channel Association] endpoints[1]: => 09:31:04.913 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 7 node ids: endpoints: 09:31:04.917 SERIAL » 0x010a0013100370052b251b95 (12 bytes) 09:31:04.918 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 27 └─[ConfigurationCCGet] parameter #: 43 09:31:04.918 CNTRLR « [Node 013] received information for multi channel association group #1: maximum # of nodes: 7 currently assigned nodes: currently assigned endpoints: 09:31:04.918 CNTRLR » [Node 013] querying multi channel association group #2... 09:31:04.923 SERIAL « [ACK] (0x06) 09:31:04.926 SERIAL « 0x0104011301e8 (6 bytes) 09:31:04.926 SERIAL » [ACK] (0x06) 09:31:04.927 DRIVER « [RES] [SendData] was sent: true 09:31:04.964 SERIAL « 0x010700131b000004f4 (9 bytes) 09:31:04.965 SERIAL » [ACK] (0x06) 09:31:04.965 DRIVER « [REQ] [SendData] callback id: 27 transmit status: OK 09:31:05.012 SERIAL « 0x010b000400100570062b010ab3 (13 bytes) 09:31:05.019 CNTRLR [Node 016] [~] [Configuration] 43: 10 => 10 09:31:05.021 SERIAL » [ACK] (0x06) 09:31:05.022 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 10 09:31:05.043 SERIAL » 0x010a00130d038e0202251c5f (12 bytes) 09:31:05.043 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 28 └─[MultiChannelAssociationCCGet] group id: 2 09:31:05.044 CNTRLR « [Node 016] parameter #43 has value: 10 09:31:05.044 CNTRLR » [Node 016] querying parameter #44 value... 09:31:05.057 SERIAL « [ACK] (0x06) 09:31:05.059 SERIAL « 0x0104011301e8 (6 bytes) 09:31:05.059 SERIAL » [ACK] (0x06) 09:31:05.061 DRIVER « [RES] [SendData] was sent: true 09:31:05.096 SERIAL « 0x010700131c000005f2 (9 bytes) 09:31:05.097 SERIAL » [ACK] (0x06) 09:31:05.097 DRIVER « [REQ] [SendData] callback id: 28 transmit status: OK 09:31:05.107 SERIAL « 0x010b0004000d058e0302070070 (13 bytes) 09:31:05.107 SERIAL » [ACK] (0x06) 09:31:05.108 CNTRLR [Node 013] [~] [Multi Channel Association] maxNodes[2]: 7 => 7 09:31:05.110 CNTRLR [Node 013] [~] [Multi Channel Association] nodeIds[2]: => 09:31:05.111 CNTRLR [Node 013] [~] [Multi Channel Association] endpoints[2]: => 09:31:05.113 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 7 node ids: endpoints: 09:31:05.120 SERIAL » 0x010a00130c03700532251d96 (12 bytes) 09:31:05.121 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 29 └─[ConfigurationCCGet] parameter #: 50 09:31:05.121 CNTRLR « [Node 013] received information for multi channel association group #2: maximum # of nodes: 7 currently assigned nodes: currently assigned endpoints: 09:31:05.121 CNTRLR » [Node 013] querying additional non-multi-channel association groups... 09:31:05.121 CNTRLR » [Node 013] querying association group #3... 09:31:05.136 SERIAL « [ACK] (0x06) 09:31:05.140 SERIAL « 0x0104011301e8 (6 bytes) 09:31:05.140 SERIAL » [ACK] (0x06) 09:31:05.141 DRIVER « [RES] [SendData] was sent: true 09:31:05.191 SERIAL « 0x010700131d000007f1 (9 bytes) 09:31:05.191 SERIAL » [ACK] (0x06) 09:31:05.192 DRIVER « [REQ] [SendData] callback id: 29 transmit status: OK 09:31:05.244 SERIAL « 0x010b0004000c057006320100bc (13 bytes) 09:31:05.249 CNTRLR [Node 012] [~] [Configuration] 50: 0 => 0 09:31:05.250 SERIAL » [ACK] (0x06) 09:31:05.251 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 0 09:31:05.254 SERIAL » 0x010a00130d03850203251e57 (12 bytes) 09:31:05.254 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 30 └─[AssociationCCGet] group id: 3 09:31:05.255 CNTRLR « [Node 012] parameter #50 has value: 0 09:31:05.255 CNTRLR [Node 012] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 09:31:05.290 SERIAL « [ACK] (0x06) 09:31:05.295 SERIAL « 0x0104011301e8 (6 bytes) 09:31:05.296 SERIAL » [ACK] (0x06) 09:31:05.296 DRIVER « [RES] [SendData] was sent: true 09:31:05.300 CNTRLR [Node 012] ProtectionCC: doing a partial interview... 09:31:05.301 CNTRLR » [Node 012] querying protection status... 09:31:05.336 SERIAL « 0x010700131e000008fd (9 bytes) 09:31:05.337 SERIAL » [ACK] (0x06) 09:31:05.337 DRIVER « [REQ] [SendData] callback id: 30 transmit status: OK 09:31:05.347 SERIAL « 0x010c0004000d0685030301000179 (14 bytes) 09:31:05.348 SERIAL » [ACK] (0x06) 09:31:05.348 CNTRLR [Node 013] [~] [Association] maxNodes[3]: 1 => 1 [internal] 09:31:05.349 CNTRLR [Node 013] [~] [Association] nodeIds[3]: 1 => 1 [internal] 09:31:05.349 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 09:31:05.352 SERIAL » 0x010a0013100370052c251f96 (12 bytes) 09:31:05.352 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 31 └─[ConfigurationCCGet] parameter #: 44 09:31:05.353 CNTRLR « [Node 013] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 09:31:05.353 CNTRLR [Node 013] [~] [Association] hasLifeline: true => true [internal] 09:31:05.354 CNTRLR [Node 013] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 09:31:05.354 CNTRLR [Node 013] Interview stage completed: CommandClasses 09:31:05.354 CNTRLR [Node 013] Interview stage completed: OverwriteConfig 09:31:05.354 CNTRLR » [Node 013] requesting node neighbors... 09:31:05.356 SERIAL « [ACK] (0x06) 09:31:05.360 SERIAL « 0x0104011301e8 (6 bytes) 09:31:05.361 SERIAL » [ACK] (0x06) 09:31:05.361 DRIVER « [RES] [SendData] was sent: true 09:31:05.399 SERIAL « 0x010700131f000004f0 (9 bytes) 09:31:05.399 SERIAL » [ACK] (0x06) 09:31:05.399 DRIVER « [REQ] [SendData] callback id: 31 transmit status: OK 09:31:05.446 SERIAL « 0x010b000400100570062c0100be (13 bytes) 09:31:05.451 CNTRLR [Node 016] [~] [Configuration] 44: 0 => 0 09:31:05.452 SERIAL » [ACK] (0x06) 09:31:05.453 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 44 value size: 1 value: 0 09:31:05.455 SERIAL » 0x010700800d00000075 (9 bytes) 09:31:05.456 DRIVER » [Node 013] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:31:05.456 CNTRLR « [Node 016] parameter #44 has value: 0 09:31:05.456 CNTRLR » [Node 016] querying parameter #50 value... 09:31:05.460 SERIAL « [ACK] (0x06) 09:31:05.461 SERIAL « 0x0120018005e8fc5f0700000000000000000000000000000000000000000000000 (34 bytes) 017 09:31:05.462 SERIAL » [ACK] (0x06) 09:31:05.462 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 12, 14, 15, 16, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 31, 33, 34, 35 09:31:05.466 SERIAL » 0x010900130c027502252099 (11 bytes) 09:31:05.467 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 32 └─[ProtectionCCGet] 09:31:05.467 CNTRLR « [Node 013] node neighbors received: 1, 3, 12, 14, 15, 16, 19, 20, 21, 22, 23 , 24, 25, 26, 27, 28, 29, 31, 33, 34, 35 09:31:05.467 CNTRLR [Node 013] Interview stage completed: Neighbors 09:31:05.499 SERIAL « [ACK] (0x06) 09:31:05.503 SERIAL « 0x0104011301e8 (6 bytes) 09:31:05.503 SERIAL » [ACK] (0x06) 09:31:05.505 DRIVER « [RES] [SendData] was sent: true 09:31:05.509 CNTRLR [Node 013] Interview completed 09:31:05.581 SERIAL « 0x010700132000000cc7 (9 bytes) 09:31:05.582 SERIAL » [ACK] (0x06) 09:31:05.583 DRIVER « [REQ] [SendData] callback id: 32 transmit status: OK 09:31:05.634 SERIAL « 0x010a0004000c04750300008f (12 bytes) 09:31:05.634 CNTRLR [Node 012] [~] [Protection] local: 0 => 0 [Endpoint 0] 09:31:05.635 CNTRLR [Node 012] [~] [Protection] rf: 0 => 0 [Endpoint 0] 09:31:05.636 SERIAL » [ACK] (0x06) 09:31:05.637 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 09:31:05.640 SERIAL » 0x010a001310037005322521b6 (12 bytes) 09:31:05.640 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 33 └─[ConfigurationCCGet] parameter #: 50 09:31:05.641 CNTRLR « [Node 012] received protection status: local: Unprotected rf Unprotected 09:31:05.641 CNTRLR [Node 012] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 09:31:05.642 CNTRLR [Node 012] FibaroVenetianBlindCC: doing a partial interview... 09:31:05.642 CNTRLR » [Node 012] Requesting venetian blind position and tilt... 09:31:05.645 SERIAL « [ACK] (0x06) 09:31:05.649 SERIAL « 0x0104011301e8 (6 bytes) 09:31:05.649 SERIAL » [ACK] (0x06) 09:31:05.650 DRIVER « [RES] [SendData] was sent: true 09:31:05.747 SERIAL « 0x010700132100000ac0 (9 bytes) 09:31:05.748 SERIAL » [ACK] (0x06) 09:31:05.748 DRIVER « [REQ] [SendData] callback id: 33 transmit status: OK 09:31:05.796 SERIAL « 0x010b00040010057006320100a0 (13 bytes) 09:31:05.801 CNTRLR [Node 016] [~] [Configuration] 50: 0 => 0 09:31:05.802 SERIAL » [ACK] (0x06) 09:31:05.803 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 0 09:31:05.809 SERIAL » 0x010800131101002522f3 (10 bytes) 09:31:05.809 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 34 └─[NoOperationCC] 09:31:05.810 CNTRLR « [Node 016] parameter #50 has value: 0 09:31:05.810 CNTRLR [Node 016] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 09:31:05.879 SERIAL « [ACK] (0x06) 09:31:05.887 SERIAL « 0x0104011301e8 (6 bytes) 09:31:05.887 SERIAL » [ACK] (0x06) 09:31:05.890 DRIVER « [RES] [SendData] was sent: true 09:31:05.894 CNTRLR [Node 016] ProtectionCC: doing a partial interview... 09:31:05.894 CNTRLR » [Node 016] querying protection status... 09:31:08.050 CNTRLR [Node 006] Beginning interview - last completed stage: RestartFromCache 09:31:08.051 CNTRLR » [Node 006] pinging the node... 09:31:08.738 DRIVER The awake timeout for node 2 has elapsed. Assuming it is asleep. 09:31:08.738 CNTRLR [Node 002] The node is now asleep. 09:31:15.777 SERIAL « 0x01070013220103e42f (9 bytes) 09:31:15.778 SERIAL » [ACK] (0x06) 09:31:15.779 DRIVER « [REQ] [SendData] callback id: 34 transmit status: NoAck 09:31:15.789 SERIAL » 0x010800131201002523f1 (10 bytes) 09:31:15.789 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 35 └─[NoOperationCC] 09:31:15.790 CNTRLR [Node 017] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 09:31:15.791 CNTRLR [Node 017] The node is asleep. 09:31:15.793 CNTRLR [Node 017] The node is ready to be used 09:31:15.795 CNTRLR [Node 017] ping failed: Failed to send the command after 1 attempts (Status No Ack) 09:31:15.800 CNTRLR [Node 017] ManufacturerSpecificCC: doing a partial interview... 09:31:15.801 CNTRLR [Node 017] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:31:15.861 SERIAL « [ACK] (0x06) 09:31:15.863 SERIAL « 0x0104011301e8 (6 bytes) 09:31:15.863 SERIAL » [ACK] (0x06) 09:31:15.865 DRIVER « [RES] [SendData] was sent: true 09:31:15.867 SERIAL « 0x0107001323000005cd (9 bytes) 09:31:15.868 SERIAL » [ACK] (0x06) 09:31:15.869 CNTRLR [Node 017] VersionCC: doing a partial interview... 09:31:15.869 CNTRLR [Node 017] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:31:15.870 CNTRLR [Node 017] trying to load device config 09:31:15.871 DRIVER « [REQ] [SendData] callback id: 35 transmit status: OK 09:31:15.875 SERIAL » 0x010800131301002524f7 (10 bytes) 09:31:15.875 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 36 └─[NoOperationCC] 09:31:15.876 CNTRLR « [Node 018] ping successful 09:31:15.878 CNTRLR [Node 018] ManufacturerSpecificCC: doing a partial interview... 09:31:15.879 CNTRLR [Node 018] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:31:15.879 CNTRLR [Node 018] VersionCC: doing a partial interview... 09:31:15.879 CNTRLR [Node 018] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:31:15.879 CNTRLR [Node 018] trying to load device config 09:31:15.884 SERIAL « [ACK] (0x06) 09:31:15.885 SERIAL « 0x0104011301e8 (6 bytes) 09:31:15.885 SERIAL » [ACK] (0x06) 09:31:15.886 DRIVER « [RES] [SendData] was sent: true 09:31:15.897 CNTRLR [Node 017] device config loaded 09:31:15.898 CNTRLR [Node 017] BatteryCC: doing a partial interview... 09:31:15.898 CNTRLR » [Node 017] querying battery status... 09:31:15.901 CNTRLR [Node 018] device config loaded 09:31:15.902 CNTRLR [Node 018] ZWavePlusCC: doing a partial interview... 09:31:15.902 CNTRLR [Node 018] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:31:15.903 CNTRLR » [Node 018] querying device endpoint information... 09:31:15.928 SERIAL « 0x0107001324000005ca (9 bytes) 09:31:15.929 SERIAL » [ACK] (0x06) 09:31:15.929 DRIVER « [REQ] [SendData] callback id: 36 transmit status: OK 09:31:15.933 SERIAL » 0x010800131401002525f1 (10 bytes) 09:31:15.934 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 37 └─[NoOperationCC] 09:31:15.934 CNTRLR « [Node 019] ping successful 09:31:15.936 CNTRLR [Node 019] ManufacturerSpecificCC: doing a partial interview... 09:31:15.936 CNTRLR [Node 019] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:31:15.936 CNTRLR [Node 019] VersionCC: doing a partial interview... 09:31:15.936 CNTRLR [Node 019] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:31:15.937 CNTRLR [Node 019] trying to load device config 09:31:15.939 SERIAL « [ACK] (0x06) 09:31:16.210 CNTRLR [Node 019] device config loaded 09:31:16.211 CNTRLR [Node 019] AssociationCC: doing a partial interview... 09:31:16.211 CNTRLR » [Node 019] querying association group #1... 09:31:16.213 SERIAL « 0x0104011301e8 (6 bytes) 09:31:16.213 SERIAL » [ACK] (0x06) 09:31:16.214 DRIVER « [RES] [SendData] was sent: true 09:31:16.248 SERIAL « 0x0107001325000002cc (9 bytes) 09:31:16.249 SERIAL » [ACK] (0x06) 09:31:16.252 DRIVER « [REQ] [SendData] callback id: 37 transmit status: OK 09:31:16.257 SERIAL » 0x010800130601002526e0 (10 bytes) 09:31:16.257 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 38 └─[NoOperationCC] 09:31:16.258 CNTRLR « [Node 020] ping successful 09:31:16.259 CNTRLR [Node 020] ManufacturerSpecificCC: doing a partial interview... 09:31:16.259 CNTRLR [Node 020] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:31:16.259 CNTRLR [Node 020] VersionCC: doing a partial interview... 09:31:16.260 CNTRLR [Node 020] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:31:16.260 CNTRLR [Node 020] trying to load device config 09:31:16.263 SERIAL « [ACK] (0x06) 09:31:16.273 CNTRLR [Node 020] device config loaded 09:31:16.274 CNTRLR [Node 020] WakeUpCC: doing a complete interview... 09:31:16.275 CNTRLR » [Node 020] retrieving wakeup interval from the device... 09:31:16.281 SERIAL « 0x0104011301e8 (6 bytes) 09:31:16.282 SERIAL » [ACK] (0x06) 09:31:16.282 DRIVER « [RES] [SendData] was sent: true 09:31:17.600 SERIAL « 0x010700132600008548 (9 bytes) 09:31:17.600 SERIAL » [ACK] (0x06) 09:31:17.601 DRIVER « [REQ] [SendData] callback id: 38 transmit status: OK 09:31:17.610 SERIAL » 0x0109001314028405252770 (11 bytes) 09:31:17.611 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[WakeUpCCIntervalGet] 09:31:17.612 CNTRLR « [Node 006] ping successful 09:31:17.665 SERIAL « [ACK] (0x06) 09:31:17.669 SERIAL « 0x0104011301e8 (6 bytes) 09:31:17.669 SERIAL » [ACK] (0x06) 09:31:17.670 DRIVER « [RES] [SendData] was sent: true 09:31:17.672 SERIAL « 0x0107001327000002ce (9 bytes) 09:31:17.673 SERIAL » [ACK] (0x06) 09:31:17.681 CNTRLR [Node 006] ManufacturerSpecificCC: doing a partial interview... 09:31:17.682 CNTRLR [Node 006] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:31:17.682 CNTRLR [Node 006] VersionCC: doing a partial interview... 09:31:17.683 CNTRLR [Node 006] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:31:17.683 CNTRLR [Node 006] trying to load device config 09:31:17.689 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 09:31:17.695 CNTRLR [Node 006] device config loaded 09:31:17.696 CNTRLR [Node 006] ZWavePlusCC: doing a partial interview... 09:31:17.696 CNTRLR [Node 006] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:31:17.697 CNTRLR » [Node 006] querying device endpoint information... 09:31:19.293 CNTRLR [Node 020] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:31:19.799 SERIAL » 0x0109001314028405252770 (11 bytes) 09:31:19.800 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[WakeUpCCIntervalGet] 09:31:19.802 SERIAL « [ACK] (0x06) 09:31:19.808 SERIAL « 0x0104011301e8 (6 bytes) 09:31:19.809 SERIAL » [ACK] (0x06) 09:31:19.810 DRIVER « [RES] [SendData] was sent: true 09:31:19.826 SERIAL « 0x0107001327000002ce (9 bytes) 09:31:19.826 SERIAL » [ACK] (0x06) 09:31:19.827 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 09:31:21.433 CNTRLR [Node 020] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:31:21.939 SERIAL » 0x0109001314028405252770 (11 bytes) 09:31:21.940 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[WakeUpCCIntervalGet] 09:31:21.942 SERIAL « [ACK] (0x06) 09:31:21.956 SERIAL « 0x0104011301e8 (6 bytes) 09:31:21.957 SERIAL » [ACK] (0x06) 09:31:21.958 DRIVER « [RES] [SendData] was sent: true 09:31:21.965 SERIAL « 0x0107001327000002ce (9 bytes) 09:31:21.966 SERIAL » [ACK] (0x06) 09:31:21.966 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 09:31:23.571 SERIAL » 0x010900131002750225288d (11 bytes) 09:31:23.572 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 40 └─[ProtectionCCGet] 09:31:23.572 CNTRLR [Node 020] Interview attempt 1/5 failed, retrying in 5000 ms... 09:31:23.573 SERIAL « [ACK] (0x06) 09:31:23.579 SERIAL « 0x0104011301e8 (6 bytes) 09:31:23.580 SERIAL » [ACK] (0x06) 09:31:23.580 DRIVER « [RES] [SendData] was sent: true 09:31:23.618 SERIAL « 0x0107001328000004c7 (9 bytes) 09:31:23.619 SERIAL » [ACK] (0x06) 09:31:23.619 DRIVER « [REQ] [SendData] callback id: 40 transmit status: OK 09:31:23.665 SERIAL « 0x010a00040010047503000093 (12 bytes) 09:31:23.682 CNTRLR [Node 016] [~] [Protection] local: 0 => 0 [Endpoint 0] 09:31:23.683 CNTRLR [Node 016] [~] [Protection] rf: 0 => 0 [Endpoint 0] 09:31:23.684 SERIAL » [ACK] (0x06) 09:31:23.685 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 09:31:23.691 SERIAL » 0x010900131202600725299e (11 bytes) 09:31:23.691 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 41 └─[MultiChannelCCEndPointGet] 09:31:23.692 CNTRLR « [Node 016] received protection status: local: Unprotected rf Unprotected 09:31:23.692 CNTRLR [Node 016] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 09:31:23.723 SERIAL « [ACK] (0x06) 09:31:23.727 SERIAL « 0x0104011301e8 (6 bytes) 09:31:23.727 SERIAL » [ACK] (0x06) 09:31:23.728 DRIVER « [RES] [SendData] was sent: true 09:31:23.731 CNTRLR [Node 016] FibaroVenetianBlindCC: doing a partial interview... 09:31:23.732 CNTRLR » [Node 016] Requesting venetian blind position and tilt... 09:31:23.778 SERIAL « 0x0107001329000008ca (9 bytes) 09:31:23.778 SERIAL » [ACK] (0x06) 09:31:23.779 DRIVER « [REQ] [SendData] callback id: 41 transmit status: OK 09:31:23.857 SERIAL « 0x010b000400120560080002008d (13 bytes) 09:31:23.858 CNTRLR [Node 018] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:31:23.858 CNTRLR [Node 018] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 09:31:23.859 CNTRLR [Node 018] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:31:23.859 CNTRLR [Node 018] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 09:31:23.859 SERIAL » [ACK] (0x06) 09:31:23.860 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:31:23.866 SERIAL » 0x010c0013100591010f2602252a41 (14 bytes) 09:31:23.866 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 42 └─[FibaroVenetianBlindCCGet] payload: 0x0f2602 09:31:23.867 CNTRLR [Node 018] The node is alive. 09:31:23.868 CNTRLR [Node 018] The node is ready to be used 09:31:23.870 CNTRLR « [Node 018] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:31:23.871 CNTRLR » [Node 018] querying all endpoints... 09:31:23.877 SERIAL « [ACK] (0x06) 09:31:23.879 SERIAL « 0x0104011301e8 (6 bytes) 09:31:23.880 SERIAL » [ACK] (0x06) 09:31:23.882 DRIVER « [RES] [SendData] was sent: true 09:31:24.693 SERIAL « 0x010700132a000009c8 (9 bytes) 09:31:24.693 SERIAL » [ACK] (0x06) 09:31:24.693 DRIVER « [REQ] [SendData] callback id: 42 transmit status: OK 09:31:24.696 SERIAL « 0x010e000400100891010f260302630036 (16 bytes) 09:31:24.697 CNTRLR [Node 016] [Manufacturer Proprietary] fibaro[venetianBlindsPositi [Endpoint 0] on]: metadata updated 09:31:24.698 CNTRLR [Node 016] [~] [Manufacturer Proprietary] fibaro[venetianBlindsPo [Endpoint 0] sition]: 1 => 99 09:31:24.699 SERIAL » [ACK] (0x06) 09:31:24.700 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[FibaroVenetianBlindCCReport] position: 99 09:31:24.703 SERIAL » 0x010a00131303850201252b7e (12 bytes) 09:31:24.704 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 43 └─[AssociationCCGet] group id: 1 09:31:24.704 CNTRLR « [Node 016] received venetian blind state: position: 99 tilt: undefined 09:31:24.705 CNTRLR [Node 016] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 09:31:24.705 CNTRLR [Node 016] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 09:31:24.735 SERIAL « [ACK] (0x06) 09:31:24.738 SERIAL « 0x0104011301e8 (6 bytes) 09:31:24.739 SERIAL » [ACK] (0x06) 09:31:24.741 DRIVER « [RES] [SendData] was sent: true 09:31:24.743 CNTRLR [Node 016] Interview stage completed: CommandClasses 09:31:24.743 CNTRLR [Node 016] Interview stage completed: OverwriteConfig 09:31:24.743 CNTRLR » [Node 016] requesting node neighbors... 09:31:24.758 SERIAL « 0x010700132b000005c5 (9 bytes) 09:31:24.758 SERIAL » [ACK] (0x06) 09:31:24.763 DRIVER « [REQ] [SendData] callback id: 43 transmit status: OK 09:31:24.811 SERIAL « 0x010b0004001305850301100071 (13 bytes) 09:31:24.812 SERIAL » [ACK] (0x06) 09:31:24.813 CNTRLR [Node 019] [~] [Association] maxNodes[1]: 16 => 16 [internal] 09:31:24.813 CNTRLR [Node 019] [~] [Association] nodeIds[1]: => [internal] 09:31:24.813 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 1 max # of nodes: 16 node IDs: reports to follow: 0 09:31:24.817 SERIAL » 0x010700801000000068 (9 bytes) 09:31:24.817 DRIVER » [Node 016] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:31:24.818 CNTRLR [Node 019] The node is alive. 09:31:24.819 CNTRLR [Node 019] The node is ready to be used 09:31:24.821 CNTRLR « [Node 019] received information for association group #1: maximum # of nodes: 16 currently assigned nodes: 09:31:24.821 CNTRLR » [Node 019] querying association group #2... 09:31:24.826 SERIAL « [ACK] (0x06) 09:31:24.827 SERIAL « 0x012001802579fd290700000000000000000000000000000000000000000000000 (34 bytes) 0d1 09:31:24.828 SERIAL » [ACK] (0x06) 09:31:24.829 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 9, 12, 13, 14, 15, 17, 19, 20, 21, 22, 23, 24, 25, 28, 30 , 33, 34, 35 09:31:24.836 SERIAL » 0x0109001306029840252c30 (11 bytes) 09:31:24.837 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 44 └─[SecurityCCNonceGet] 09:31:24.837 CNTRLR « [Node 016] node neighbors received: 1, 3, 6, 9, 12, 13, 14, 15, 17, 19, 20, 21, 22, 23, 24, 25, 28, 30, 33, 34, 35 09:31:24.837 CNTRLR [Node 016] Interview stage completed: Neighbors 09:31:24.837 CNTRLR [Node 016] Interview completed 09:31:24.840 SERIAL « [ACK] (0x06) 09:31:24.844 SERIAL « 0x0104011301e8 (6 bytes) 09:31:24.845 SERIAL » [ACK] (0x06) 09:31:24.845 DRIVER « [RES] [SendData] was sent: true 09:31:26.268 SERIAL « 0x010700132c00008f48 (9 bytes) 09:31:26.269 SERIAL » [ACK] (0x06) 09:31:26.270 DRIVER « [REQ] [SendData] callback id: 44 transmit status: OK 09:31:26.356 SERIAL « 0x0110000400060a9880d1ec97a0a2f8f4a0fb (18 bytes) 09:31:26.357 SERIAL » [ACK] (0x06) 09:31:26.359 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xd1ec97a0a2f8f4a0 09:31:26.366 SERIAL » 0x011d00130616988160c52cfa86d13f5b223bbad1ab877006a83eb062252ddc (31 bytes) 09:31:26.367 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 45 └─[SecurityCCCommandEncapsulation] │ nonce id: 209 └─[MultiChannelCCEndPointGet] 09:31:26.370 SERIAL « [ACK] (0x06) 09:31:26.377 SERIAL « 0x0104011301e8 (6 bytes) 09:31:26.378 SERIAL » [ACK] (0x06) 09:31:26.379 DRIVER « [RES] [SendData] was sent: true 09:31:26.497 SERIAL « 0x010700132d00000cca (9 bytes) 09:31:26.498 SERIAL » [ACK] (0x06) 09:31:26.499 DRIVER « [REQ] [SendData] callback id: 45 transmit status: OK 09:31:26.583 SERIAL « 0x0108000400060298402f (10 bytes) 09:31:26.583 SERIAL » [ACK] (0x06) 09:31:26.585 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:31:26.595 SERIAL » 0x01110013060a988067f61afdd6646448240025 (19 bytes) 09:31:26.595 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x67f61afdd6646448 09:31:26.598 SERIAL « [ACK] (0x06) 09:31:26.604 SERIAL « 0x0104011301e8 (6 bytes) 09:31:26.605 SERIAL » [ACK] (0x06) 09:31:26.606 DRIVER « [RES] [SendData] was sent: true 09:31:26.814 SERIAL « 0x011f000400061998819a581d2567958639ad7dca346ae367fe1f455955f5528b1 (33 bytes) 1 09:31:26.816 SERIAL » [ACK] (0x06) 09:31:26.818 CNTRLR [Node 006] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:31:26.819 CNTRLR [Node 006] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 09:31:26.820 CNTRLR [Node 006] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:31:26.820 CNTRLR [Node 006] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 09:31:26.821 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:31:26.828 SERIAL » 0x010b00131204600bffff252e91 (13 bytes) 09:31:26.829 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 46 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:31:26.830 CNTRLR « [Node 006] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:31:26.830 CNTRLR » [Node 006] querying all endpoints... 09:31:26.836 SERIAL « [ACK] (0x06) 09:31:26.839 SERIAL « 0x0104011301e8 (6 bytes) 09:31:26.839 SERIAL » [ACK] (0x06) 09:31:26.840 DRIVER « [RES] [SendData] was sent: true 09:31:26.929 SERIAL « 0x010700132e000009cc (9 bytes) 09:31:26.929 SERIAL » [ACK] (0x06) 09:31:26.930 DRIVER « [REQ] [SendData] callback id: 46 transmit status: OK 09:31:27.008 SERIAL « 0x010d0004001207600c00ffff01028c (15 bytes) 09:31:27.010 SERIAL » [ACK] (0x06) 09:31:27.012 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 09:31:27.018 SERIAL » 0x010a00131303850202252f79 (12 bytes) 09:31:27.019 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 47 └─[AssociationCCGet] group id: 2 09:31:27.020 CNTRLR « [Node 018] received endpoints: 1, 2 09:31:27.020 CNTRLR » [Node 018] querying capabilities for endpoint #1... 09:31:27.026 SERIAL « [ACK] (0x06) 09:31:27.033 SERIAL « 0x0104011301e8 (6 bytes) 09:31:27.034 SERIAL » [ACK] (0x06) 09:31:27.035 DRIVER « [RES] [SendData] was sent: true 09:31:27.126 SERIAL « 0x010700132f00000ace (9 bytes) 09:31:27.126 SERIAL » [ACK] (0x06) 09:31:27.127 DRIVER « [REQ] [SendData] callback id: 47 transmit status: OK 09:31:27.179 SERIAL « 0x010b0004001305850302100072 (13 bytes) 09:31:27.179 SERIAL » [ACK] (0x06) 09:31:27.181 CNTRLR [Node 019] [~] [Association] maxNodes[2]: 16 => 16 [internal] 09:31:27.182 CNTRLR [Node 019] [~] [Association] nodeIds[2]: => [internal] 09:31:27.183 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 2 max # of nodes: 16 node IDs: reports to follow: 0 09:31:27.193 SERIAL » 0x010900130602984025302c (11 bytes) 09:31:27.193 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 48 └─[SecurityCCNonceGet] 09:31:27.194 CNTRLR « [Node 019] received information for association group #2: maximum # of nodes: 16 currently assigned nodes: 09:31:27.194 CNTRLR » [Node 019] querying association group #3... 09:31:27.200 SERIAL « [ACK] (0x06) 09:31:27.203 SERIAL « 0x0104011301e8 (6 bytes) 09:31:27.204 SERIAL » [ACK] (0x06) 09:31:27.205 DRIVER « [RES] [SendData] was sent: true 09:31:27.261 SERIAL « 0x010c000400030631050422050aef (14 bytes) 09:31:27.264 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:31:27.265 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 189.8 => 129 [Endpoint 0] 09:31:27.266 SERIAL » [ACK] (0x06) 09:31:27.268 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 129 09:31:28.573 CNTRLR [Node 020] Beginning interview - last completed stage: RestartFromCache 09:31:28.573 CNTRLR » [Node 020] pinging the node... 09:31:28.707 SERIAL « 0x01070013300000974c (9 bytes) 09:31:28.708 SERIAL » [ACK] (0x06) 09:31:28.709 DRIVER « [REQ] [SendData] callback id: 48 transmit status: OK 09:31:28.766 SERIAL « 0x010c000410030631050422093ec7 (14 bytes) 09:31:28.768 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:31:28.769 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 129 => 236.6 [Endpoint 0] 09:31:28.770 SERIAL » [ACK] (0x06) 09:31:28.772 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 236.6 09:31:28.806 SERIAL « 0x0110000400060a9880adb703db7f44b462d0 (18 bytes) 09:31:28.807 SERIAL » [ACK] (0x06) 09:31:28.808 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xadb703db7f44b462 09:31:28.814 SERIAL » 0x011f0013061898811abf11caf2e08c3039150baaf6ad41efe0bc5e68414025312 (33 bytes) 3 09:31:28.815 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 49 └─[SecurityCCCommandEncapsulation] │ nonce id: 173 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:31:28.818 SERIAL « [ACK] (0x06) 09:31:28.825 SERIAL « 0x0104011301e8 (6 bytes) 09:31:28.826 SERIAL » [ACK] (0x06) 09:31:28.827 DRIVER « [RES] [SendData] was sent: true 09:31:28.948 SERIAL « 0x010700133100000dd7 (9 bytes) 09:31:28.948 SERIAL » [ACK] (0x06) 09:31:28.949 DRIVER « [REQ] [SendData] callback id: 49 transmit status: OK 09:31:28.978 SERIAL « 0x010c000410030631050422093ec7 (14 bytes) 09:31:28.979 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:31:28.980 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 236.6 => 236.6 [Endpoint 0] 09:31:28.981 SERIAL » [ACK] (0x06) 09:31:28.982 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 236.6 09:31:28.995 SERIAL « 0x010c000410030631050422093ec7 (14 bytes) 09:31:28.996 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:31:28.997 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 236.6 => 236.6 [Endpoint 0] 09:31:28.998 SERIAL » [ACK] (0x06) 09:31:28.999 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 236.6 09:31:29.031 SERIAL « 0x0108000400060298402f (10 bytes) 09:31:29.032 SERIAL » [ACK] (0x06) 09:31:29.033 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:31:29.041 SERIAL » 0x01110013060a988031506dd98f0c3d612400c7 (19 bytes) 09:31:29.041 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x31506dd98f0c3d61 09:31:29.044 SERIAL « [ACK] (0x06) 09:31:29.050 SERIAL « 0x0104011301e8 (6 bytes) 09:31:29.051 SERIAL » [ACK] (0x06) 09:31:29.052 DRIVER « [RES] [SendData] was sent: true 09:31:29.056 SERIAL « 0x010c000410030631050422093ec7 (14 bytes) 09:31:29.057 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:31:29.058 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 236.6 => 236.6 [Endpoint 0] 09:31:29.059 SERIAL » [ACK] (0x06) 09:31:29.060 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 236.6 09:31:29.096 SERIAL « 0x010c000410030631050422093ec7 (14 bytes) 09:31:29.097 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:31:29.098 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 236.6 => 236.6 [Endpoint 0] 09:31:29.099 SERIAL » [ACK] (0x06) 09:31:29.100 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 236.6 09:31:29.145 SERIAL « 0x010c000410030631050422093ec7 (14 bytes) 09:31:29.145 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:31:29.146 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 236.6 => 236.6 [Endpoint 0] 09:31:29.147 SERIAL » [ACK] (0x06) 09:31:29.148 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 236.6 09:31:29.171 SERIAL « 0x010c000410030631050422093ec7 (14 bytes) 09:31:29.172 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:31:29.173 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 236.6 => 236.6 [Endpoint 0] 09:31:29.174 SERIAL » [ACK] (0x06) 09:31:29.175 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 236.6 09:31:29.240 SERIAL « 0x010c000410030631050422093ec7 (14 bytes) 09:31:29.241 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:31:29.242 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 236.6 => 236.6 [Endpoint 0] 09:31:29.243 SERIAL » [ACK] (0x06) 09:31:29.244 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 236.6 09:31:29.349 SERIAL « 0x010c000400030631050422069274 (14 bytes) 09:31:29.350 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:31:29.351 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 236.6 => 168.2 [Endpoint 0] 09:31:29.352 SERIAL » [ACK] (0x06) 09:31:29.354 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 168.2 09:31:29.483 SERIAL « 0x010c000400030631050422069274 (14 bytes) 09:31:29.484 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:31:29.485 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 168.2 => 168.2 [Endpoint 0] 09:31:29.486 SERIAL » [ACK] (0x06) 09:31:29.487 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 168.2 09:31:29.530 SERIAL « 0x010c000400030631050422069274 (14 bytes) 09:31:29.532 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:31:29.533 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 168.2 => 168.2 [Endpoint 0] 09:31:29.534 SERIAL » [ACK] (0x06) 09:31:29.536 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 168.2 09:31:30.554 CNTRLR [Node 006] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:31:31.060 SERIAL » 0x010900130602984025322e (11 bytes) 09:31:31.061 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 50 └─[SecurityCCNonceGet] 09:31:31.063 SERIAL « [ACK] (0x06) 09:31:31.069 SERIAL « 0x0104011301e8 (6 bytes) 09:31:31.070 SERIAL » [ACK] (0x06) 09:31:31.070 DRIVER « [RES] [SendData] was sent: true 09:31:31.127 SERIAL « 0x0107001332000006df (9 bytes) 09:31:31.128 SERIAL » [ACK] (0x06) 09:31:31.129 DRIVER « [REQ] [SendData] callback id: 50 transmit status: OK 09:31:31.215 SERIAL « 0x0110000400060a9880b465a1c0576f827f8a (18 bytes) 09:31:31.216 SERIAL » [ACK] (0x06) 09:31:31.217 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xb465a1c0576f827f 09:31:31.223 SERIAL » 0x011f001306189881841a6d9b367ad7fb4a4d7c2f08b4acb81fdc488f44d325318 (33 bytes) 7 09:31:31.224 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 49 └─[SecurityCCCommandEncapsulation] │ nonce id: 180 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:31:31.227 SERIAL « [ACK] (0x06) 09:31:31.234 SERIAL « 0x0104011301e8 (6 bytes) 09:31:31.235 SERIAL » [ACK] (0x06) 09:31:31.236 DRIVER « [RES] [SendData] was sent: true 09:31:31.356 SERIAL « 0x010700133100000dd7 (9 bytes) 09:31:31.357 SERIAL » [ACK] (0x06) 09:31:31.358 DRIVER « [REQ] [SendData] callback id: 49 transmit status: OK 09:31:32.960 CNTRLR [Node 006] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:31:33.469 SERIAL » 0x010900130602984025332f (11 bytes) 09:31:33.469 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 51 └─[SecurityCCNonceGet] 09:31:33.471 SERIAL « [ACK] (0x06) 09:31:33.477 SERIAL « 0x0104011301e8 (6 bytes) 09:31:33.478 SERIAL » [ACK] (0x06) 09:31:33.479 DRIVER « [RES] [SendData] was sent: true 09:31:33.536 SERIAL « 0x0107001333000006de (9 bytes) 09:31:33.537 SERIAL » [ACK] (0x06) 09:31:33.537 DRIVER « [REQ] [SendData] callback id: 51 transmit status: OK 09:31:33.625 SERIAL « 0x0110000400060a988056011260d260bae436 (18 bytes) 09:31:33.626 SERIAL » [ACK] (0x06) 09:31:33.627 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x56011260d260bae4 09:31:33.632 SERIAL » 0x011f0013061898814849bd1b5acbdbda24b07ba4bc56f764ed5ebfde9a3225319 (33 bytes) f 09:31:33.633 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 49 └─[SecurityCCCommandEncapsulation] │ nonce id: 86 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:31:33.636 SERIAL « [ACK] (0x06) 09:31:33.644 SERIAL « 0x0104011301e8 (6 bytes) 09:31:33.644 SERIAL » [ACK] (0x06) 09:31:33.645 DRIVER « [RES] [SendData] was sent: true 09:31:33.766 SERIAL « 0x010700133100000dd7 (9 bytes) 09:31:33.767 SERIAL » [ACK] (0x06) 09:31:33.767 DRIVER « [REQ] [SendData] callback id: 49 transmit status: OK 09:31:34.262 SERIAL « 0x010c0004000306310504220840a8 (14 bytes) 09:31:34.263 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:31:34.263 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 168.2 => 211.2 [Endpoint 0] 09:31:34.264 SERIAL » [ACK] (0x06) 09:31:34.265 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 211.2 09:31:35.375 SERIAL » 0x010800131401002534e0 (10 bytes) 09:31:35.376 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 52 └─[NoOperationCC] 09:31:35.377 CNTRLR [Node 006] Did not respond to endpoint query, assuming that endpoints are sequ ential 09:31:35.377 CNTRLR » [Node 006] querying capabilities for endpoint #1... 09:31:35.382 SERIAL « [ACK] (0x06) 09:31:35.384 SERIAL « 0x0104011301e8 (6 bytes) 09:31:35.385 SERIAL » [ACK] (0x06) 09:31:35.386 DRIVER « [RES] [SendData] was sent: true 09:31:35.401 SERIAL « 0x0107001334000003dc (9 bytes) 09:31:35.402 SERIAL » [ACK] (0x06) 09:31:35.403 DRIVER « [REQ] [SendData] callback id: 52 transmit status: OK 09:31:35.409 SERIAL » 0x010a0013120360090125358f (12 bytes) 09:31:35.410 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 53 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:31:35.411 CNTRLR « [Node 020] ping successful 09:31:35.413 CNTRLR [Node 020] ManufacturerSpecificCC: doing a partial interview... 09:31:35.414 CNTRLR [Node 020] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:31:35.459 SERIAL « [ACK] (0x06) 09:31:35.463 SERIAL « 0x0104011301e8 (6 bytes) 09:31:35.463 SERIAL » [ACK] (0x06) 09:31:35.465 DRIVER « [RES] [SendData] was sent: true 09:31:35.466 CNTRLR [Node 020] VersionCC: doing a partial interview... 09:31:35.466 CNTRLR [Node 020] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:31:35.467 CNTRLR [Node 020] trying to load device config 09:31:35.468 SERIAL « 0x0107001335000005db (9 bytes) 09:31:35.468 SERIAL » [ACK] (0x06) 09:31:35.469 DRIVER « [REQ] [SendData] callback id: 53 transmit status: OK 09:31:35.478 CNTRLR [Node 020] device config loaded 09:31:35.479 CNTRLR [Node 020] WakeUpCC: doing a complete interview... 09:31:35.479 CNTRLR » [Node 020] retrieving wakeup interval from the device... 09:31:35.554 SERIAL « 0x011a0004001214600a0108065e8e404353989f596c71758081852292 (28 bytes) 09:31:35.555 CNTRLR [Node 018] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 1] [internal] 64,67,83,152,159,89,108,113,117,128,129,133,34 => 94,142,64,67,83,152,159,89,1 08,113,117,128,129,133,34 09:31:35.556 SERIAL » [ACK] (0x06) 09:31:35.556 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:31:35.560 SERIAL » 0x0109001314028405253661 (11 bytes) 09:31:35.560 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 54 └─[WakeUpCCIntervalGet] 09:31:35.560 CNTRLR « [Node 018] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:31:35.561 CNTRLR » [Node 018] querying capabilities for endpoint #2... 09:31:35.563 SERIAL « [ACK] (0x06) 09:31:35.568 SERIAL « 0x0104011301e8 (6 bytes) 09:31:35.568 SERIAL » [ACK] (0x06) 09:31:35.569 DRIVER « [RES] [SendData] was sent: true 09:31:35.656 SERIAL « 0x0107001336000007da (9 bytes) 09:31:35.656 SERIAL » [ACK] (0x06) 09:31:35.659 DRIVER « [REQ] [SendData] callback id: 54 transmit status: OK 09:31:36.263 SERIAL « 0x010c000400030631050422068660 (14 bytes) 09:31:36.264 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:31:36.265 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 211.2 => 167 [Endpoint 0] 09:31:36.266 SERIAL » [ACK] (0x06) 09:31:36.268 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 167 09:31:37.263 CNTRLR [Node 020] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:31:37.768 SERIAL » 0x0109001314028405253661 (11 bytes) 09:31:37.769 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 54 └─[WakeUpCCIntervalGet] 09:31:37.771 SERIAL « [ACK] (0x06) 09:31:37.777 SERIAL « 0x0104011301e8 (6 bytes) 09:31:37.778 SERIAL » [ACK] (0x06) 09:31:37.779 DRIVER « [RES] [SendData] was sent: true 09:31:37.795 SERIAL « 0x0107001336000002df (9 bytes) 09:31:37.795 SERIAL » [ACK] (0x06) 09:31:37.796 DRIVER « [REQ] [SendData] callback id: 54 transmit status: OK 09:31:39.402 CNTRLR [Node 020] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:31:39.907 SERIAL » 0x0109001314028405253661 (11 bytes) 09:31:39.908 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 54 └─[WakeUpCCIntervalGet] 09:31:39.910 SERIAL « [ACK] (0x06) 09:31:39.916 SERIAL « 0x0104011301e8 (6 bytes) 09:31:39.917 SERIAL » [ACK] (0x06) 09:31:39.917 DRIVER « [RES] [SendData] was sent: true 09:31:39.934 SERIAL « 0x0107001336000002df (9 bytes) 09:31:39.934 SERIAL » [ACK] (0x06) 09:31:39.941 DRIVER « [REQ] [SendData] callback id: 54 transmit status: OK 09:31:41.550 SERIAL » 0x010a00131303850203253760 (12 bytes) 09:31:41.551 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 55 └─[AssociationCCGet] group id: 3 09:31:41.552 CNTRLR [Node 020] Interview attempt 2/5 failed, retrying in 10000 ms... 09:31:41.554 SERIAL « [ACK] (0x06) 09:31:41.560 SERIAL « 0x0104011301e8 (6 bytes) 09:31:41.560 SERIAL » [ACK] (0x06) 09:31:41.561 DRIVER « [RES] [SendData] was sent: true 09:31:41.607 SERIAL « 0x0107001337000005d9 (9 bytes) 09:31:41.607 SERIAL » [ACK] (0x06) 09:31:41.608 DRIVER « [REQ] [SendData] callback id: 55 transmit status: OK 09:31:41.658 SERIAL « 0x010c000400130685030301000167 (14 bytes) 09:31:41.659 SERIAL » [ACK] (0x06) 09:31:41.660 CNTRLR [Node 019] [~] [Association] maxNodes[3]: 1 => 1 [internal] 09:31:41.661 CNTRLR [Node 019] [~] [Association] nodeIds[3]: 1 => 1 [internal] 09:31:41.662 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 09:31:41.670 SERIAL » 0x0109001306029840253824 (11 bytes) 09:31:41.670 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 56 └─[SecurityCCNonceGet] 09:31:41.671 CNTRLR « [Node 019] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 09:31:41.672 CNTRLR [Node 019] [~] [Association] hasLifeline: true => true [internal] 09:31:41.672 CNTRLR [Node 019] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:31:41.727 SERIAL « [ACK] (0x06) 09:31:41.733 SERIAL « 0x0104011301e8 (6 bytes) 09:31:41.733 SERIAL » [ACK] (0x06) 09:31:41.734 DRIVER « [RES] [SendData] was sent: true 09:31:41.739 CNTRLR [Node 019] BinarySwitchCC: doing a partial interview... 09:31:41.739 CNTRLR » [Node 019] querying Binary Switch state... 09:31:43.144 SERIAL « 0x010700133800009340 (9 bytes) 09:31:43.145 SERIAL » [ACK] (0x06) 09:31:43.145 DRIVER « [REQ] [SendData] callback id: 56 transmit status: OK 09:31:43.228 SERIAL « 0x0110000400060a9880a18c89b6671b30a908 (18 bytes) 09:31:43.229 SERIAL » [ACK] (0x06) 09:31:43.229 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xa18c89b6671b30a9 09:31:43.233 SERIAL » 0x011e001306179881b3899808526cd70819c38482a11627a1283f0ded142539a3 (32 bytes) 09:31:43.233 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 57 └─[SecurityCCCommandEncapsulation] │ nonce id: 161 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:31:43.236 SERIAL « [ACK] (0x06) 09:31:43.243 SERIAL « 0x0104011301e8 (6 bytes) 09:31:43.243 SERIAL » [ACK] (0x06) 09:31:43.244 DRIVER « [RES] [SendData] was sent: true 09:31:43.355 SERIAL « 0x010c00040002063105030a000bc5 (14 bytes) 09:31:43.356 CNTRLR [Node 002] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 09:31:43.357 CNTRLR [Node 002] [~] [Multilevel Sensor] Illuminance: 8 => 11 [Endpoint 0] 09:31:43.358 SERIAL » [ACK] (0x06) 09:31:43.359 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 11 09:31:43.429 SERIAL « 0x010c0004000306310504220550b5 (14 bytes) 09:31:43.430 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:31:43.430 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 167 => 136 [Endpoint 0] 09:31:43.431 SERIAL » [ACK] (0x06) 09:31:43.432 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 136 09:31:43.556 SERIAL « 0x0108000400060298402f (10 bytes) 09:31:43.556 SERIAL » [ACK] (0x06) 09:31:43.557 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:31:46.263 SERIAL « 0x010c00040003063105042209c32a (14 bytes) 09:31:46.264 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:31:46.266 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 136 => 249.9 [Endpoint 0] 09:31:46.267 SERIAL » [ACK] (0x06) 09:31:46.269 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 249.9 09:31:47.263 SERIAL « 0x010c00040003063105042206f117 (14 bytes) 09:31:47.265 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:31:47.266 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 249.9 => 177.7 [Endpoint 0] 09:31:47.267 SERIAL » [ACK] (0x06) 09:31:47.269 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 177.7 09:31:49.146 SERIAL « 0x010700133900024f9f (9 bytes) 09:31:49.146 SERIAL » [ACK] (0x06) 09:31:49.147 DRIVER « [REQ] [SendData] callback id: 57 transmit status: OK 09:31:49.151 SERIAL » 0x01110013060a9880d2547fda28106c0c2400b6 (19 bytes) 09:31:49.152 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xd2547fda28106c0c 09:31:49.154 SERIAL « [ACK] (0x06) 09:31:49.161 SERIAL « 0x0104011301e8 (6 bytes) 09:31:49.162 SERIAL » [ACK] (0x06) 09:31:49.162 DRIVER « [RES] [SendData] was sent: true 09:31:49.204 SERIAL « 0x0123000400061d9881e48b903b07f1949d77f26854809518b5dbafd202f56bda6 (37 bytes) e094a4469 09:31:49.206 DRIVER Message with invalid data received. Dropping it: 0x0123000400061d9881e48b903b07f1949d77f26854809518b5dbafd202f56bda6e094a4469 09:31:49.206 SERIAL » [ACK] (0x06) 09:31:50.754 CNTRLR [Node 006] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:31:51.264 SERIAL » 0x0109001306029840253a26 (11 bytes) 09:31:51.271 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 58 └─[SecurityCCNonceGet] 09:31:51.274 SERIAL « [ACK] (0x06) 09:31:51.280 SERIAL « 0x0104011301e8 (6 bytes) 09:31:51.281 SERIAL » [ACK] (0x06) 09:31:51.282 DRIVER « [RES] [SendData] was sent: true 09:31:51.553 CNTRLR [Node 020] Beginning interview - last completed stage: RestartFromCache 09:31:51.554 CNTRLR » [Node 020] pinging the node... 09:31:52.561 SERIAL « 0x010700133a00008150 (9 bytes) 09:31:52.561 SERIAL » [ACK] (0x06) 09:31:52.563 DRIVER « [REQ] [SendData] callback id: 58 transmit status: OK 09:31:52.583 SERIAL « 0x0110000400060a98804e54149b026c7e5c26 (18 bytes) 09:31:52.584 SERIAL » [ACK] (0x06) 09:31:52.585 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x4e54149b026c7e5c 09:31:52.592 SERIAL » 0x011e0013061798816ad998ecb85b687a0bcc81844ed057022162eef6cb253949 (32 bytes) 09:31:52.593 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 57 └─[SecurityCCCommandEncapsulation] │ nonce id: 78 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:31:52.596 SERIAL « [ACK] (0x06) 09:31:52.603 SERIAL « 0x0104011301e8 (6 bytes) 09:31:52.604 SERIAL » [ACK] (0x06) 09:31:52.605 DRIVER « [RES] [SendData] was sent: true 09:31:52.628 SERIAL « 0x0107001339000003d1 (9 bytes) 09:31:52.629 SERIAL » [ACK] (0x06) 09:31:52.631 DRIVER « [REQ] [SendData] callback id: 57 transmit status: OK 09:31:52.650 SERIAL « 0x0108000400060298402f (10 bytes) 09:31:52.651 SERIAL » [ACK] (0x06) 09:31:52.653 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:31:52.666 SERIAL » 0x01110013060a98802a595b8069edaefc2400b3 (19 bytes) 09:31:52.667 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x2a595b8069edaefc 09:31:52.669 SERIAL « [ACK] (0x06) 09:31:52.675 SERIAL « 0x0104011301e8 (6 bytes) 09:31:52.676 SERIAL » [ACK] (0x06) 09:31:52.676 DRIVER « [RES] [SendData] was sent: true 09:31:52.718 SERIAL « 0x0123000400061d98815d44366f27ac2a7b1687ab5027fd15d0e5c52ad7d7adbc5 (37 bytes) 0dbdf007a 09:31:52.719 SERIAL » [ACK] (0x06) 09:31:52.721 CNTRLR [Node 006] [~] [Multi Channel] commandClasses: 94,152, [Endpoint 1] [internal] 159,34 => 94,152,159,34 09:31:52.722 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 09:31:52.726 SERIAL » 0x01080013140100253bef (10 bytes) 09:31:52.727 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 59 └─[NoOperationCC] 09:31:52.727 CNTRLR « [Node 006] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 09:31:52.727 CNTRLR » [Node 006] querying capabilities for endpoint #2... 09:31:52.731 SERIAL « [ACK] (0x06) 09:31:52.734 SERIAL « 0x0104011301e8 (6 bytes) 09:31:52.735 SERIAL » [ACK] (0x06) 09:31:52.736 DRIVER « [RES] [SendData] was sent: true 09:31:52.752 SERIAL « 0x010700133b000003d3 (9 bytes) 09:31:52.752 SERIAL » [ACK] (0x06) 09:31:52.753 DRIVER « [REQ] [SendData] callback id: 59 transmit status: OK 09:31:52.763 SERIAL » 0x010a00131203600902253c85 (12 bytes) 09:31:52.764 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 60 └─[MultiChannelCCCapabilityGet] endpoint: 2 09:31:52.765 CNTRLR « [Node 020] ping successful 09:31:52.767 CNTRLR [Node 020] ManufacturerSpecificCC: doing a partial interview... 09:31:52.767 CNTRLR [Node 020] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:31:52.818 SERIAL « [ACK] (0x06) 09:31:52.823 SERIAL « 0x0104011301e8 (6 bytes) 09:31:52.823 SERIAL » [ACK] (0x06) 09:31:52.825 DRIVER « [RES] [SendData] was sent: true 09:31:52.830 CNTRLR [Node 020] VersionCC: doing a partial interview... 09:31:52.831 CNTRLR [Node 020] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:31:52.831 CNTRLR [Node 020] trying to load device config 09:31:52.833 SERIAL « 0x010700133c000006d1 (9 bytes) 09:31:52.834 SERIAL » [ACK] (0x06) 09:31:52.835 DRIVER « [REQ] [SendData] callback id: 60 transmit status: OK 09:31:52.848 CNTRLR [Node 020] device config loaded 09:31:52.850 CNTRLR [Node 020] WakeUpCC: doing a complete interview... 09:31:52.850 CNTRLR » [Node 020] retrieving wakeup interval from the device... 09:31:52.903 SERIAL « 0x01160004001210600a0221015e8e31989f596c7180852222 (24 bytes) 09:31:52.903 CNTRLR [Node 018] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 2] [internal] 49,152,159,89,108,113,128,133,34 => 94,142,49,152,159,89,108,113,128,133,34 09:31:52.904 SERIAL » [ACK] (0x06) 09:31:52.905 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:31:52.908 SERIAL » 0x0109001314028405253d6a (11 bytes) 09:31:52.908 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 61 └─[WakeUpCCIntervalGet] 09:31:52.909 CNTRLR « [Node 018] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:31:52.909 CNTRLR [Node 018] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:31:52.910 CNTRLR [Node 018] BatteryCC: doing a partial interview... 09:31:52.910 CNTRLR » [Node 018] querying battery status... 09:31:52.913 SERIAL « [ACK] (0x06) 09:31:52.916 SERIAL « 0x0104011301e8 (6 bytes) 09:31:52.917 SERIAL » [ACK] (0x06) 09:31:52.917 DRIVER « [RES] [SendData] was sent: true 09:31:52.986 SERIAL « 0x010700133d000007d1 (9 bytes) 09:31:52.987 SERIAL » [ACK] (0x06) 09:31:52.987 DRIVER « [REQ] [SendData] callback id: 61 transmit status: OK 09:31:54.594 CNTRLR [Node 020] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:31:55.100 SERIAL » 0x0109001314028405253d6a (11 bytes) 09:31:55.101 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 61 └─[WakeUpCCIntervalGet] 09:31:55.103 SERIAL « [ACK] (0x06) 09:31:55.109 SERIAL « 0x0104011301e8 (6 bytes) 09:31:55.110 SERIAL » [ACK] (0x06) 09:31:55.111 DRIVER « [RES] [SendData] was sent: true 09:31:55.126 SERIAL « 0x010700133d000002d4 (9 bytes) 09:31:55.127 SERIAL » [ACK] (0x06) 09:31:55.128 DRIVER « [REQ] [SendData] callback id: 61 transmit status: OK 09:31:56.733 CNTRLR [Node 020] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:31:57.238 SERIAL » 0x0109001314028405253d6a (11 bytes) 09:31:57.239 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 61 └─[WakeUpCCIntervalGet] 09:31:57.241 SERIAL « [ACK] (0x06) 09:31:57.247 SERIAL « 0x0104011301e8 (6 bytes) 09:31:57.248 SERIAL » [ACK] (0x06) 09:31:57.249 DRIVER « [RES] [SendData] was sent: true 09:31:57.265 SERIAL « 0x010700133d000002d4 (9 bytes) 09:31:57.266 SERIAL » [ACK] (0x06) 09:31:57.266 DRIVER « [REQ] [SendData] callback id: 61 transmit status: OK 09:31:58.876 SERIAL » 0x0109001313022502253ec8 (11 bytes) 09:31:58.877 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 62 └─[BinarySwitchCCGet] 09:31:58.878 CNTRLR [Node 020] Interview attempt 3/5 failed, retrying in 15000 ms... 09:31:58.879 SERIAL « [ACK] (0x06) 09:31:58.885 SERIAL « 0x0104011301e8 (6 bytes) 09:31:58.886 SERIAL » [ACK] (0x06) 09:31:58.887 DRIVER « [RES] [SendData] was sent: true 09:31:58.931 SERIAL « 0x010700133e000005d0 (9 bytes) 09:31:58.932 SERIAL » [ACK] (0x06) 09:31:58.933 DRIVER « [REQ] [SendData] callback id: 62 transmit status: OK 09:31:58.982 SERIAL « 0x010900040013032503fe3a (11 bytes) 09:31:58.984 CNTRLR [Node 019] [~] [Binary Switch] currentValue: "unknown" => "unknow [Endpoint 0] n" 09:31:58.985 SERIAL » [ACK] (0x06) 09:31:58.986 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: unknown 09:31:58.995 SERIAL » 0x0109001306029840253f23 (11 bytes) 09:31:58.996 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 63 └─[SecurityCCNonceGet] 09:31:58.997 CNTRLR « [Node 019] received Binary Switch state: current value: unknown 09:31:58.997 CNTRLR [Node 019] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 09:31:59.071 SERIAL « [ACK] (0x06) 09:31:59.076 SERIAL « 0x0104011301e8 (6 bytes) 09:31:59.076 SERIAL » [ACK] (0x06) 09:31:59.078 DRIVER « [RES] [SendData] was sent: true 09:31:59.080 CNTRLR [Node 019] MultilevelSwitchCC: doing a partial interview... 09:31:59.081 CNTRLR » [Node 019] requesting current switch state... 09:32:00.355 SERIAL « 0x010700133f0000885c (9 bytes) 09:32:00.355 SERIAL » [ACK] (0x06) 09:32:00.356 DRIVER « [REQ] [SendData] callback id: 63 transmit status: OK 09:32:00.377 SERIAL « 0x0110000400060a98805b679d4a6f9182bed6 (18 bytes) 09:32:00.377 SERIAL » [ACK] (0x06) 09:32:00.378 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x5b679d4a6f9182be 09:32:00.384 SERIAL » 0x011e001306179881e040e7bc9cc4ff240defd23c5b680a82fb166494f42540b9 (32 bytes) 09:32:00.385 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 64 └─[SecurityCCCommandEncapsulation] │ nonce id: 91 └─[MultiChannelCCCapabilityGet] endpoint: 2 09:32:00.388 SERIAL « [ACK] (0x06) 09:32:00.395 SERIAL « 0x0104011301e8 (6 bytes) 09:32:00.396 SERIAL » [ACK] (0x06) 09:32:00.396 DRIVER « [RES] [SendData] was sent: true 09:32:00.420 SERIAL « 0x0107001340000004af (9 bytes) 09:32:00.420 SERIAL » [ACK] (0x06) 09:32:00.424 DRIVER « [REQ] [SendData] callback id: 64 transmit status: OK 09:32:00.442 SERIAL « 0x0108000400060298402f (10 bytes) 09:32:00.442 SERIAL » [ACK] (0x06) 09:32:00.443 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:32:00.452 SERIAL » 0x01110013060a988098dff43a4d2707932400ba (19 bytes) 09:32:00.452 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x98dff43a4d270793 09:32:00.455 SERIAL « [ACK] (0x06) 09:32:00.461 SERIAL « 0x0104011301e8 (6 bytes) 09:32:00.461 SERIAL » [ACK] (0x06) 09:32:00.462 DRIVER « [RES] [SendData] was sent: true 09:32:00.504 SERIAL « 0x0123000400061d98811ca42ecb7c18fe88bb8e7f5606eba6028bff987a7488b3c (37 bytes) bbfafd012 09:32:00.505 SERIAL » [ACK] (0x06) 09:32:00.506 CNTRLR [Node 006] [~] [Multi Channel] commandClasses: 94,152, [Endpoint 2] [internal] 159,34 => 94,152,159,34 09:32:00.507 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 09:32:00.514 SERIAL » 0x0109001312028002254113 (11 bytes) 09:32:00.514 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 65 └─[BatteryCCGet] 09:32:00.515 CNTRLR « [Node 006] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 09:32:00.515 CNTRLR [Node 006] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:32:00.565 SERIAL « [ACK] (0x06) 09:32:00.568 SERIAL « 0x0104011301e8 (6 bytes) 09:32:00.568 SERIAL » [ACK] (0x06) 09:32:00.569 DRIVER « [RES] [SendData] was sent: true 09:32:00.571 SERIAL « 0x0107001341000005af (9 bytes) 09:32:00.571 SERIAL » [ACK] (0x06) 09:32:00.572 CNTRLR [Node 006] BatteryCC: doing a partial interview... 09:32:00.572 CNTRLR » [Node 006] querying battery status... 09:32:00.574 DRIVER « [REQ] [SendData] callback id: 65 transmit status: OK 09:32:02.177 CNTRLR [Node 018] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:32:02.265 SERIAL « 0x010c00040003063105042204a743 (14 bytes) 09:32:02.266 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:32:02.266 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 177.7 => 119.1 [Endpoint 0] 09:32:02.267 SERIAL » [ACK] (0x06) 09:32:02.268 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 119.1 09:32:02.667 SERIAL « 0x01090004001b033003ff26 (11 bytes) 09:32:02.668 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:32:02.670 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:32:02.671 SERIAL » [ACK] (0x06) 09:32:02.673 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:32:02.684 SERIAL » 0x0109001312028002254113 (11 bytes) 09:32:02.685 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 65 └─[BatteryCCGet] 09:32:02.688 SERIAL « [ACK] (0x06) 09:32:02.693 SERIAL « 0x0104011301e8 (6 bytes) 09:32:02.693 SERIAL » [ACK] (0x06) 09:32:02.694 DRIVER « [RES] [SendData] was sent: true 09:32:02.767 SERIAL « 0x0107001341000008a2 (9 bytes) 09:32:02.768 SERIAL » [ACK] (0x06) 09:32:02.769 DRIVER « [REQ] [SendData] callback id: 65 transmit status: OK 09:32:02.858 SERIAL « 0x01090004001b032001ff34 (11 bytes) 09:32:02.859 SERIAL » [ACK] (0x06) 09:32:02.860 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:32:02.862 CNTRLR [Node 027] treating BasicCC Set as a report 09:32:02.863 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:32:04.374 CNTRLR [Node 018] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:32:04.877 SERIAL » 0x0109001312028002254113 (11 bytes) 09:32:04.878 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 65 └─[BatteryCCGet] 09:32:04.879 SERIAL « [ACK] (0x06) 09:32:04.885 SERIAL « 0x0104011301e8 (6 bytes) 09:32:04.886 SERIAL » [ACK] (0x06) 09:32:04.886 DRIVER « [RES] [SendData] was sent: true 09:32:04.933 SERIAL « 0x0107001341000005af (9 bytes) 09:32:04.933 SERIAL » [ACK] (0x06) 09:32:04.933 DRIVER « [REQ] [SendData] callback id: 65 transmit status: OK 09:32:06.265 SERIAL « 0x010c0004000306310504220a6b81 (14 bytes) 09:32:06.267 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:32:06.268 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 119.1 => 266.7 [Endpoint 0] 09:32:06.269 SERIAL » [ACK] (0x06) 09:32:06.271 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 266.7 09:32:06.542 SERIAL » 0x01090013130226022542b7 (11 bytes) 09:32:06.543 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 66 └─[MultilevelSwitchCCGet] 09:32:06.544 CNTRLR [Node 018] Battery status query timed out - skipping because it is not critica l... 09:32:06.545 CNTRLR [Node 018] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:32:06.622 SERIAL « [ACK] (0x06) 09:32:06.629 SERIAL « 0x0104011301e8 (6 bytes) 09:32:06.629 SERIAL » [ACK] (0x06) 09:32:06.630 DRIVER « [RES] [SendData] was sent: true 09:32:06.634 SERIAL « 0x0107001342000005ac (9 bytes) 09:32:06.634 SERIAL » [ACK] (0x06) 09:32:06.640 CNTRLR [Node 018] ZWavePlusCC: doing a partial interview... [Endpoint 1] 09:32:06.640 CNTRLR [Node 018] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 09:32:06.641 CNTRLR [Node 018] ThermostatModeCC: doing a partial interview... [Endpoint 1] 09:32:06.641 CNTRLR » [Node 018] querying current thermostat mode... [Endpoint 1] 09:32:06.643 DRIVER « [REQ] [SendData] callback id: 66 transmit status: OK 09:32:06.649 SERIAL « 0x01090004001303260362a5 (11 bytes) 09:32:06.650 CNTRLR [Node 019] [~] [Multilevel Switch] currentValue: 98 => 98 [Endpoint 0] 09:32:06.651 SERIAL » [ACK] (0x06) 09:32:06.652 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 98 09:32:06.657 SERIAL » 0x010900130602984025435f (11 bytes) 09:32:06.657 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 67 └─[SecurityCCNonceGet] 09:32:06.658 CNTRLR [Node 019] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 09:32:06.658 CNTRLR [Node 019] MultilevelSensorCC: doing a partial interview... 09:32:06.658 CNTRLR » [Node 019] querying current sensor reading... 09:32:06.662 SERIAL « [ACK] (0x06) 09:32:06.666 SERIAL « 0x0104011301e8 (6 bytes) 09:32:06.666 SERIAL » [ACK] (0x06) 09:32:06.667 DRIVER « [RES] [SendData] was sent: true 09:32:07.969 SERIAL « 0x01070013430000822a (9 bytes) 09:32:07.970 SERIAL » [ACK] (0x06) 09:32:07.970 DRIVER « [REQ] [SendData] callback id: 67 transmit status: OK 09:32:07.992 SERIAL « 0x0110000400060a9880bffc2ab258aeaee09c (18 bytes) 09:32:07.992 SERIAL » [ACK] (0x06) 09:32:07.993 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xbffc2ab258aeaee0 09:32:07.998 SERIAL » 0x011d00130616988112ed5bf4ebb5e10f29c86dbf52b862fee12745a6254419 (31 bytes) 09:32:07.998 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 68 └─[SecurityCCCommandEncapsulation] │ nonce id: 191 └─[BatteryCCGet] 09:32:08.001 SERIAL « [ACK] (0x06) 09:32:08.008 SERIAL « 0x0104011301e8 (6 bytes) 09:32:08.009 SERIAL » [ACK] (0x06) 09:32:08.009 DRIVER « [RES] [SendData] was sent: true 09:32:08.033 SERIAL « 0x0107001344000003ac (9 bytes) 09:32:08.034 SERIAL » [ACK] (0x06) 09:32:08.034 DRIVER « [REQ] [SendData] callback id: 68 transmit status: OK 09:32:08.121 SERIAL « 0x0108000400060298402f (10 bytes) 09:32:08.122 SERIAL » [ACK] (0x06) 09:32:08.123 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:32:08.133 SERIAL » 0x01110013060a98805bd0338d94e6c01a240050 (19 bytes) 09:32:08.134 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x5bd0338d94e6c01a 09:32:08.136 SERIAL « [ACK] (0x06) 09:32:08.143 SERIAL « 0x0104011301e8 (6 bytes) 09:32:08.143 SERIAL » [ACK] (0x06) 09:32:08.144 DRIVER « [RES] [SendData] was sent: true 09:32:08.184 SERIAL « 0x011d000400061798810212e5afa9424d7b7a7d5a915b3c15db9e64f44ddd92 (31 bytes) 09:32:08.185 SERIAL » [ACK] (0x06) 09:32:08.187 CNTRLR [Node 006] [~] [Battery] level: 89 => 89 [Endpoint 0] 09:32:08.188 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 0] 09:32:08.189 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[BatteryCCReport] level: 89 is low: false 09:32:08.206 SERIAL » 0x010d00131206600d000140022545bb (15 bytes) 09:32:08.207 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 69 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:32:08.208 CNTRLR « [Node 006] received response for battery information: level: 89 09:32:08.209 CNTRLR [Node 006] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:32:08.274 SERIAL « [ACK] (0x06) 09:32:08.282 SERIAL « 0x0104011301e8 (6 bytes) 09:32:08.283 SERIAL » [ACK] (0x06) 09:32:08.284 DRIVER « [RES] [SendData] was sent: true 09:32:08.297 CNTRLR [Node 006] ZWavePlusCC: doing a partial interview... [Endpoint 1] 09:32:08.298 CNTRLR [Node 006] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 09:32:08.299 CNTRLR [Node 006] ThermostatModeCC: doing a partial interview... [Endpoint 1] 09:32:08.299 CNTRLR » [Node 006] querying current thermostat mode... [Endpoint 1] 09:32:08.303 SERIAL « 0x0107001345000005ab (9 bytes) 09:32:08.303 SERIAL » [ACK] (0x06) 09:32:08.304 DRIVER « [REQ] [SendData] callback id: 69 transmit status: OK 09:32:08.400 SERIAL « 0x010c0004000306310504220548ad (14 bytes) 09:32:08.401 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:32:08.401 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 266.7 => 135.2 [Endpoint 0] 09:32:08.402 SERIAL » [ACK] (0x06) 09:32:08.403 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 135.2 09:32:09.908 CNTRLR [Node 018] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:32:10.266 SERIAL « 0x010c00040003063105042209947d (14 bytes) 09:32:10.267 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:32:10.269 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 135.2 => 245.2 [Endpoint 0] 09:32:10.270 SERIAL » [ACK] (0x06) 09:32:10.271 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 245.2 09:32:10.413 SERIAL » 0x010d00131206600d000140022545bb (15 bytes) 09:32:10.414 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 69 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:32:10.416 SERIAL « [ACK] (0x06) 09:32:10.423 SERIAL « 0x0104011301e8 (6 bytes) 09:32:10.423 SERIAL » [ACK] (0x06) 09:32:10.424 DRIVER « [RES] [SendData] was sent: true 09:32:10.472 SERIAL « 0x0107001345000006a8 (9 bytes) 09:32:10.472 SERIAL » [ACK] (0x06) 09:32:10.473 DRIVER « [REQ] [SendData] callback id: 69 transmit status: OK 09:32:12.081 CNTRLR [Node 018] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:32:12.587 SERIAL » 0x010d00131206600d000140022545bb (15 bytes) 09:32:12.588 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 69 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:32:12.590 SERIAL « [ACK] (0x06) 09:32:12.596 SERIAL « 0x0104011301e8 (6 bytes) 09:32:12.597 SERIAL » [ACK] (0x06) 09:32:12.598 DRIVER « [RES] [SendData] was sent: true 09:32:12.647 SERIAL « 0x0107001345000005ab (9 bytes) 09:32:12.647 SERIAL » [ACK] (0x06) 09:32:12.648 DRIVER « [REQ] [SendData] callback id: 69 transmit status: OK 09:32:13.879 CNTRLR [Node 020] Beginning interview - last completed stage: RestartFromCache 09:32:13.880 CNTRLR » [Node 020] pinging the node... 09:32:14.257 SERIAL » 0x01080013140100254692 (10 bytes) 09:32:14.258 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 70 └─[NoOperationCC] 09:32:14.259 CNTRLR [Node 018] Interview attempt 1/5 failed, retrying in 5000 ms... 09:32:14.261 SERIAL « [ACK] (0x06) 09:32:14.266 SERIAL « 0x0104011301e8 (6 bytes) 09:32:14.267 SERIAL » [ACK] (0x06) 09:32:14.268 DRIVER « [RES] [SendData] was sent: true 09:32:14.284 SERIAL « 0x0107001346000002af (9 bytes) 09:32:14.284 SERIAL » [ACK] (0x06) 09:32:14.285 DRIVER « [REQ] [SendData] callback id: 70 transmit status: OK 09:32:14.295 SERIAL » 0x01090013130231042547a3 (11 bytes) 09:32:14.295 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 71 └─[MultilevelSensorCCGet] 09:32:14.296 CNTRLR « [Node 020] ping successful 09:32:14.298 CNTRLR [Node 020] ManufacturerSpecificCC: doing a partial interview... 09:32:14.299 CNTRLR [Node 020] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:32:14.361 SERIAL « [ACK] (0x06) 09:32:14.367 SERIAL « 0x0104011301e8 (6 bytes) 09:32:14.368 SERIAL » [ACK] (0x06) 09:32:14.368 DRIVER « [RES] [SendData] was sent: true 09:32:14.371 CNTRLR [Node 020] VersionCC: doing a partial interview... 09:32:14.372 CNTRLR [Node 020] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:32:14.372 CNTRLR [Node 020] trying to load device config 09:32:14.373 SERIAL « 0x0107001347000005a9 (9 bytes) 09:32:14.373 SERIAL » [ACK] (0x06) 09:32:14.374 DRIVER « [REQ] [SendData] callback id: 71 transmit status: OK 09:32:14.384 CNTRLR [Node 020] device config loaded 09:32:14.384 CNTRLR [Node 020] WakeUpCC: doing a complete interview... 09:32:14.385 CNTRLR » [Node 020] retrieving wakeup interval from the device... 09:32:14.402 SERIAL « 0x010c0004001306310504220000f0 (14 bytes) 09:32:14.403 CNTRLR [Node 019] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:32:14.403 CNTRLR [Node 019] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 09:32:14.404 SERIAL » [ACK] (0x06) 09:32:14.405 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 09:32:14.410 SERIAL » 0x010900131402840525481f (11 bytes) 09:32:14.411 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 72 └─[WakeUpCCIntervalGet] 09:32:14.411 CNTRLR « [Node 019] received current sensor reading: sensor type: Power value: 0 W 09:32:14.411 CNTRLR [Node 019] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 09:32:14.412 CNTRLR [Node 019] MeterCC: doing a partial interview... 09:32:14.412 CNTRLR » [Node 019] querying meter value (type = Electric, scale = kWh)... 09:32:14.416 SERIAL « [ACK] (0x06) 09:32:14.419 SERIAL « 0x0104011301e8 (6 bytes) 09:32:14.419 SERIAL » [ACK] (0x06) 09:32:14.419 DRIVER « [RES] [SendData] was sent: true 09:32:14.496 SERIAL « 0x0107001348000008ab (9 bytes) 09:32:14.497 SERIAL » [ACK] (0x06) 09:32:14.497 DRIVER « [REQ] [SendData] callback id: 72 transmit status: OK 09:32:16.100 CNTRLR [Node 020] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:32:16.606 SERIAL » 0x010900131402840525481f (11 bytes) 09:32:16.607 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 72 └─[WakeUpCCIntervalGet] 09:32:16.609 SERIAL « [ACK] (0x06) 09:32:16.615 SERIAL « 0x0104011301e8 (6 bytes) 09:32:16.616 SERIAL » [ACK] (0x06) 09:32:16.617 DRIVER « [RES] [SendData] was sent: true 09:32:16.633 SERIAL « 0x0107001348000002a1 (9 bytes) 09:32:16.634 SERIAL » [ACK] (0x06) 09:32:16.634 DRIVER « [REQ] [SendData] callback id: 72 transmit status: OK 09:32:18.239 CNTRLR [Node 020] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:32:18.745 SERIAL » 0x010900131402840525481f (11 bytes) 09:32:18.746 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 72 └─[WakeUpCCIntervalGet] 09:32:18.748 SERIAL « [ACK] (0x06) 09:32:18.754 SERIAL « 0x0104011301e8 (6 bytes) 09:32:18.755 SERIAL » [ACK] (0x06) 09:32:18.756 DRIVER « [RES] [SendData] was sent: true 09:32:18.771 SERIAL « 0x0107001348000003a0 (9 bytes) 09:32:18.772 SERIAL » [ACK] (0x06) 09:32:18.773 DRIVER « [REQ] [SendData] callback id: 72 transmit status: OK 09:32:19.260 CNTRLR [Node 018] Beginning interview - last completed stage: RestartFromCache 09:32:19.261 CNTRLR » [Node 018] pinging the node... 09:32:20.381 SERIAL » 0x0108001312010025499b (10 bytes) 09:32:20.382 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 73 └─[NoOperationCC] 09:32:20.383 CNTRLR [Node 020] Interview attempt 4/5 failed, retrying in 20000 ms... 09:32:20.384 SERIAL « [ACK] (0x06) 09:32:20.390 SERIAL « 0x0104011301e8 (6 bytes) 09:32:20.391 SERIAL » [ACK] (0x06) 09:32:20.391 DRIVER « [RES] [SendData] was sent: true 09:32:20.436 SERIAL « 0x0107001349000005a7 (9 bytes) 09:32:20.436 SERIAL » [ACK] (0x06) 09:32:20.437 DRIVER « [REQ] [SendData] callback id: 73 transmit status: OK 09:32:20.463 SERIAL » 0x0109001306029840254a56 (11 bytes) 09:32:20.464 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 74 └─[SecurityCCNonceGet] 09:32:20.465 CNTRLR « [Node 018] ping successful 09:32:20.469 CNTRLR [Node 018] ManufacturerSpecificCC: doing a partial interview... 09:32:20.469 CNTRLR [Node 018] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:32:20.514 SERIAL « [ACK] (0x06) 09:32:20.517 SERIAL « 0x0104011301e8 (6 bytes) 09:32:20.521 SERIAL » [ACK] (0x06) 09:32:20.521 DRIVER « [RES] [SendData] was sent: true 09:32:20.523 CNTRLR [Node 018] VersionCC: doing a partial interview... 09:32:20.524 CNTRLR [Node 018] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:32:20.524 CNTRLR [Node 018] trying to load device config 09:32:20.529 CNTRLR [Node 018] device config loaded 09:32:20.530 CNTRLR [Node 018] ZWavePlusCC: doing a partial interview... 09:32:20.530 CNTRLR [Node 018] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:32:20.530 CNTRLR » [Node 018] querying device endpoint information... 09:32:21.723 SERIAL « 0x010700134a00007edf (9 bytes) 09:32:21.724 SERIAL » [ACK] (0x06) 09:32:21.725 DRIVER « [REQ] [SendData] callback id: 74 transmit status: OK 09:32:21.745 SERIAL « 0x0110000400060a98809195e2e109c7ed66bd (18 bytes) 09:32:21.746 SERIAL » [ACK] (0x06) 09:32:21.747 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x9195e2e109c7ed66 09:32:21.759 SERIAL » 0x01210013061a988127dd934c7b3ea8f8cf4cd4c651c02891163767583519b2e12 (35 bytes) 54b4e 09:32:21.760 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 75 └─[SecurityCCCommandEncapsulation] │ nonce id: 145 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:32:21.764 SERIAL « [ACK] (0x06) 09:32:21.771 SERIAL « 0x0104011301e8 (6 bytes) 09:32:21.772 SERIAL » [ACK] (0x06) 09:32:21.773 DRIVER « [RES] [SendData] was sent: true 09:32:21.797 SERIAL « 0x010700134b000003a3 (9 bytes) 09:32:21.797 SERIAL » [ACK] (0x06) 09:32:21.798 DRIVER « [REQ] [SendData] callback id: 75 transmit status: OK 09:32:21.916 SERIAL « 0x0108000400060298402f (10 bytes) 09:32:21.916 SERIAL » [ACK] (0x06) 09:32:21.917 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:32:21.924 SERIAL » 0x01110013060a98809fcb916f753b1b902400a2 (19 bytes) 09:32:21.924 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x9fcb916f753b1b90 09:32:21.926 SERIAL « [ACK] (0x06) 09:32:21.933 SERIAL « 0x0104011301e8 (6 bytes) 09:32:21.933 SERIAL » [ACK] (0x06) 09:32:21.934 DRIVER « [RES] [SendData] was sent: true 09:32:21.975 SERIAL « 0x0121000400061b988175c0e6f4596bbfa018215edf4a9afd979f6c7b664805600 (35 bytes) 0b326 09:32:21.977 SERIAL » [ACK] (0x06) 09:32:21.979 CNTRLR [Node 006] [~] [Thermostat Mode] mode: 0 => 0 [Endpoint 1] 09:32:21.981 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Off 09:32:21.987 SERIAL » 0x010a00131303320100254cac (12 bytes) 09:32:21.987 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 76 └─[MeterCCGet] duration: kWh 09:32:21.992 CNTRLR « [Node 006] received current thermostat mode: Off [Endpoint 1] 09:32:21.992 CNTRLR [Node 006] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 1] [internal] ue => true 09:32:22.044 SERIAL « [ACK] (0x06) 09:32:22.048 SERIAL « 0x0104011301e8 (6 bytes) 09:32:22.048 SERIAL » [ACK] (0x06) 09:32:22.050 DRIVER « [RES] [SendData] was sent: true 09:32:22.052 CNTRLR [Node 006] ThermostatSetpointCC: doing a partial interview... [Endpoint 1] 09:32:22.052 CNTRLR » [Node 006] querying current value of setpoint Heating... [Endpoint 1] 09:32:22.061 SERIAL « 0x010700134c000005a2 (9 bytes) 09:32:22.061 SERIAL » [ACK] (0x06) 09:32:22.072 DRIVER « [REQ] [SendData] callback id: 76 transmit status: OK 09:32:22.100 SERIAL « 0x0110000400130a320221440000010a0000ac (18 bytes) 09:32:22.101 CNTRLR [Node 019] [~] [Meter] value[65537]: 2.66 => 2.66 [Endpoint 0] 09:32:22.102 CNTRLR [Node 019] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 09:32:22.103 SERIAL » [ACK] (0x06) 09:32:22.105 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 2.66 time delta: 0 seconds 09:32:22.108 SERIAL » 0x0109001312026007254dfa (11 bytes) 09:32:22.108 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 77 └─[MultiChannelCCEndPointGet] 09:32:22.108 CNTRLR » [Node 019] querying meter value (type = Electric, scale = W)... 09:32:22.114 SERIAL « [ACK] (0x06) 09:32:22.116 SERIAL « 0x0104011301e8 (6 bytes) 09:32:22.117 SERIAL » [ACK] (0x06) 09:32:22.117 DRIVER « [RES] [SendData] was sent: true 09:32:22.217 SERIAL « 0x010700134d00000aac (9 bytes) 09:32:22.218 SERIAL » [ACK] (0x06) 09:32:22.218 DRIVER « [REQ] [SendData] callback id: 77 transmit status: OK 09:32:22.297 SERIAL « 0x010b000400120560080002008d (13 bytes) 09:32:22.298 CNTRLR [Node 018] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:32:22.298 CNTRLR [Node 018] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 09:32:22.298 CNTRLR [Node 018] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:32:22.298 CNTRLR [Node 018] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 09:32:22.299 SERIAL » [ACK] (0x06) 09:32:22.299 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:32:22.304 SERIAL » 0x0109001306029840254e52 (11 bytes) 09:32:22.304 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 78 └─[SecurityCCNonceGet] 09:32:22.305 CNTRLR « [Node 018] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:32:22.305 CNTRLR » [Node 018] querying all endpoints... 09:32:22.310 SERIAL « [ACK] (0x06) 09:32:22.312 SERIAL « 0x0104011301e8 (6 bytes) 09:32:22.312 SERIAL » [ACK] (0x06) 09:32:22.313 DRIVER « [RES] [SendData] was sent: true 09:32:22.389 SERIAL « 0x010700134e000008ad (9 bytes) 09:32:22.390 SERIAL » [ACK] (0x06) 09:32:22.390 DRIVER « [REQ] [SendData] callback id: 78 transmit status: OK 09:32:22.412 SERIAL « 0x0110000400060a98808236f22b8f13228aa6 (18 bytes) 09:32:22.412 SERIAL » [ACK] (0x06) 09:32:22.413 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x8236f22b8f13228a 09:32:22.416 SERIAL » 0x01220013061b98811d02e3915014f12599781120be139b4e82ced48329e24a053 (36 bytes) 8254f52 09:32:22.417 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 79 └─[SecurityCCCommandEncapsulation] │ nonce id: 130 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:32:22.420 SERIAL « [ACK] (0x06) 09:32:22.427 SERIAL « 0x0104011301e8 (6 bytes) 09:32:22.427 SERIAL » [ACK] (0x06) 09:32:22.427 DRIVER « [RES] [SendData] was sent: true 09:32:22.452 SERIAL « 0x010700134f000003a7 (9 bytes) 09:32:22.453 SERIAL » [ACK] (0x06) 09:32:22.453 DRIVER « [REQ] [SendData] callback id: 79 transmit status: OK 09:32:22.545 SERIAL « 0x0108000400060298402f (10 bytes) 09:32:22.545 SERIAL » [ACK] (0x06) 09:32:22.546 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:32:22.553 SERIAL » 0x01110013060a98809e183f6ce2db009d2400bc (19 bytes) 09:32:22.553 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x9e183f6ce2db009d 09:32:22.555 SERIAL « [ACK] (0x06) 09:32:22.562 SERIAL « 0x0104011301e8 (6 bytes) 09:32:22.562 SERIAL » [ACK] (0x06) 09:32:22.563 DRIVER « [RES] [SendData] was sent: true 09:32:22.605 SERIAL « 0x0124000400061e988187d64289cbfeb27d0c5d59f99bd492830d94319e4c26f85 (38 bytes) 837a70dbfcf 09:32:22.606 SERIAL » [ACK] (0x06) 09:32:22.611 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 1] 09:32:22.612 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 09:32:22.613 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 09:32:22.617 SERIAL » 0x010a001313033201102550a0 (12 bytes) 09:32:22.617 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 80 └─[MeterCCGet] duration: W 09:32:22.618 CNTRLR « [Node 006] received current value of setpoint Heating: 10 °C [Endpoint 1] 09:32:22.619 CNTRLR [Node 006] [~] [Thermostat Setpoint] interviewComplete [Endpoint 1] [internal] : true => true 09:32:22.653 SERIAL « [ACK] (0x06) 09:32:22.658 SERIAL « 0x0104011301e8 (6 bytes) 09:32:22.658 SERIAL » [ACK] (0x06) 09:32:22.659 DRIVER « [RES] [SendData] was sent: true 09:32:22.661 CNTRLR [Node 006] NotificationCC: doing a partial interview... [Endpoint 1] 09:32:22.662 CNTRLR » [Node 006] querying notification status for Power Management... [Endpoint 1] 09:32:22.672 SERIAL « 0x0107001350000005be (9 bytes) 09:32:22.672 SERIAL » [ACK] (0x06) 09:32:22.673 DRIVER « [REQ] [SendData] callback id: 80 transmit status: OK 09:32:22.726 SERIAL « 0x010e00040013083202213200000000cd (16 bytes) 09:32:22.726 CNTRLR [Node 019] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 09:32:22.727 CNTRLR [Node 019] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 09:32:22.727 SERIAL » [ACK] (0x06) 09:32:22.729 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 09:32:22.733 SERIAL » 0x010b00131204600bffff2551ee (13 bytes) 09:32:22.734 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 81 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:32:22.734 CNTRLR [Node 019] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 09:32:22.735 CNTRLR [Node 019] ConfigurationCC: Loading configuration parameters from device confi g 09:32:22.744 CNTRLR [Node 019] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:32:22.745 CNTRLR [Node 019] [Configuration] 1: metadata updated 09:32:22.747 CNTRLR [Node 019] [Configuration] 2: metadata updated 09:32:22.755 CNTRLR [Node 019] [Configuration] 3: metadata updated 09:32:22.757 CNTRLR [Node 019] [Configuration] 10: metadata updated 09:32:22.759 CNTRLR [Node 019] [Configuration] 12: metadata updated 09:32:22.761 CNTRLR [Node 019] [Configuration] 13: metadata updated 09:32:22.763 CNTRLR [Node 019] [Configuration] 14: metadata updated 09:32:22.765 CNTRLR [Node 019] [Configuration] 17: metadata updated 09:32:22.767 CNTRLR [Node 019] [Configuration] 18: metadata updated 09:32:22.769 CNTRLR [Node 019] [Configuration] 22: metadata updated 09:32:22.771 CNTRLR [Node 019] [Configuration] 29: metadata updated 09:32:22.773 CNTRLR [Node 019] [Configuration] 30: metadata updated 09:32:22.775 CNTRLR [Node 019] [Configuration] 31: metadata updated 09:32:22.778 CNTRLR [Node 019] [Configuration] 32: metadata updated 09:32:22.779 CNTRLR [Node 019] [Configuration] 33: metadata updated 09:32:22.781 CNTRLR [Node 019] [Configuration] 35: metadata updated 09:32:22.783 CNTRLR [Node 019] [Configuration] 40: metadata updated 09:32:22.785 CNTRLR [Node 019] [Configuration] 42: metadata updated 09:32:22.787 CNTRLR [Node 019] [Configuration] 43: metadata updated 09:32:22.788 CNTRLR [Node 019] [Configuration] 44: metadata updated 09:32:22.790 CNTRLR [Node 019] [Configuration] 50: metadata updated 09:32:22.792 CNTRLR [Node 019] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:32:22.792 CNTRLR » [Node 019] querying parameter #1 value... 09:32:22.883 SERIAL « [ACK] (0x06) 09:32:22.885 SERIAL « 0x0104011301e8 (6 bytes) 09:32:22.885 SERIAL » [ACK] (0x06) 09:32:22.899 DRIVER « [RES] [SendData] was sent: true 09:32:22.908 SERIAL « 0x010700135100000bb1 (9 bytes) 09:32:22.908 SERIAL » [ACK] (0x06) 09:32:22.910 DRIVER « [REQ] [SendData] callback id: 81 transmit status: OK 09:32:22.934 SERIAL « 0x010d0004001207600c00ffff01028c (15 bytes) 09:32:22.949 SERIAL » [ACK] (0x06) 09:32:22.953 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 09:32:22.965 SERIAL » 0x010900130602984025524e (11 bytes) 09:32:22.965 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 82 └─[SecurityCCNonceGet] 09:32:22.969 CNTRLR « [Node 018] received endpoints: 1, 2 09:32:22.969 CNTRLR » [Node 018] querying capabilities for endpoint #1... 09:32:22.977 SERIAL « [ACK] (0x06) 09:32:22.984 SERIAL « 0x0104011301e8 (6 bytes) 09:32:22.985 SERIAL » [ACK] (0x06) 09:32:22.987 DRIVER « [RES] [SendData] was sent: true 09:32:23.020 SERIAL « 0x0107001352000005bc (9 bytes) 09:32:23.020 SERIAL » [ACK] (0x06) 09:32:23.020 DRIVER « [REQ] [SendData] callback id: 82 transmit status: OK 09:32:23.042 SERIAL « 0x0110000400060a9880907f12ff0b165d57ea (18 bytes) 09:32:23.043 SERIAL » [ACK] (0x06) 09:32:23.046 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x907f12ff0b165d57 09:32:23.050 SERIAL » 0x01240013061d9881aec235d7ee3ab5a109dbd0edcdf7a629a756906cd490a35ea (38 bytes) 4e72225537d 09:32:23.051 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 83 └─[SecurityCCCommandEncapsulation] │ nonce id: 144 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: Power Management 09:32:23.054 SERIAL « [ACK] (0x06) 09:32:23.061 SERIAL « 0x0104011301e8 (6 bytes) 09:32:23.062 SERIAL » [ACK] (0x06) 09:32:23.062 DRIVER « [RES] [SendData] was sent: true 09:32:23.087 SERIAL « 0x0107001353000003bb (9 bytes) 09:32:23.087 SERIAL » [ACK] (0x06) 09:32:23.088 DRIVER « [REQ] [SendData] callback id: 83 transmit status: OK 09:32:23.110 SERIAL « 0x0108000400060298402f (10 bytes) 09:32:23.110 SERIAL » [ACK] (0x06) 09:32:23.111 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:32:23.115 SERIAL » 0x01110013060a988048bf521e6ff241022400a8 (19 bytes) 09:32:23.116 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x48bf521e6ff24102 09:32:23.118 SERIAL « [ACK] (0x06) 09:32:23.124 SERIAL « 0x0104011301e8 (6 bytes) 09:32:23.125 SERIAL » [ACK] (0x06) 09:32:23.125 DRIVER « [RES] [SendData] was sent: true 09:32:23.169 SERIAL « 0x012700040006219881ceb38a42fdcfac9eb82cf5b9dc8002595ecf544e1a8f482 (41 bytes) eeb0628e2cfde4086 09:32:23.170 SERIAL » [ACK] (0x06) 09:32:23.172 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 09:32:23.175 SERIAL » 0x010a001313037005012554f3 (12 bytes) 09:32:23.176 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 84 └─[ConfigurationCCGet] parameter #: 1 09:32:23.177 CNTRLR [Node 006] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 1] 54 09:32:23.178 CNTRLR » [Node 006] querying notification status for System... [Endpoint 1] 09:32:23.181 SERIAL « [ACK] (0x06) 09:32:23.184 SERIAL « 0x0104011301e8 (6 bytes) 09:32:23.184 SERIAL » [ACK] (0x06) 09:32:23.185 DRIVER « [RES] [SendData] was sent: true 09:32:23.230 SERIAL « 0x0107001354000006b9 (9 bytes) 09:32:23.230 SERIAL » [ACK] (0x06) 09:32:23.231 DRIVER « [REQ] [SendData] callback id: 84 transmit status: OK 09:32:24.834 CNTRLR [Node 019] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:32:25.337 SERIAL » 0x010a001313037005012554f3 (12 bytes) 09:32:25.337 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 84 └─[ConfigurationCCGet] parameter #: 1 09:32:25.339 SERIAL « [ACK] (0x06) 09:32:25.345 SERIAL « 0x0104011301e8 (6 bytes) 09:32:25.345 SERIAL » [ACK] (0x06) 09:32:25.346 DRIVER « [RES] [SendData] was sent: true 09:32:25.392 SERIAL « 0x0107001354000005ba (9 bytes) 09:32:25.392 SERIAL » [ACK] (0x06) 09:32:25.393 DRIVER « [REQ] [SendData] callback id: 84 transmit status: OK 09:32:26.996 CNTRLR [Node 019] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:32:27.503 SERIAL » 0x010a001313037005012554f3 (12 bytes) 09:32:27.504 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 84 └─[ConfigurationCCGet] parameter #: 1 09:32:27.506 SERIAL « [ACK] (0x06) 09:32:27.512 SERIAL « 0x0104011301e8 (6 bytes) 09:32:27.513 SERIAL » [ACK] (0x06) 09:32:27.514 DRIVER « [RES] [SendData] was sent: true 09:32:27.559 SERIAL « 0x0107001354000005ba (9 bytes) 09:32:27.559 SERIAL » [ACK] (0x06) 09:32:27.560 DRIVER « [REQ] [SendData] callback id: 84 transmit status: OK 09:32:29.167 SERIAL » 0x010a001312036009012555ef (12 bytes) 09:32:29.167 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 85 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:32:29.168 CNTRLR « [Node 019] received no value for parameter #1 09:32:29.168 CNTRLR » [Node 019] querying parameter #2 value... 09:32:29.171 SERIAL « [ACK] (0x06) 09:32:29.175 SERIAL « 0x0104011301e8 (6 bytes) 09:32:29.175 SERIAL » [ACK] (0x06) 09:32:29.176 DRIVER « [RES] [SendData] was sent: true 09:32:29.225 SERIAL « 0x0107001355000005bb (9 bytes) 09:32:29.225 SERIAL » [ACK] (0x06) 09:32:29.226 DRIVER « [REQ] [SendData] callback id: 85 transmit status: OK 09:32:29.315 SERIAL « 0x011a0004001214600a0108065e8e404353989f596c71758081852292 (28 bytes) 09:32:29.317 CNTRLR [Node 018] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 1] [internal] 64,67,83,152,159,89,108,113,117,128,129,133,34 => 94,142,64,67,83,152,159,89,1 08,113,117,128,129,133,34 09:32:29.317 SERIAL » [ACK] (0x06) 09:32:29.319 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:32:29.329 SERIAL » 0x010900130602984025564a (11 bytes) 09:32:29.330 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 86 └─[SecurityCCNonceGet] 09:32:29.331 CNTRLR « [Node 018] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:32:29.332 CNTRLR » [Node 018] querying capabilities for endpoint #2... 09:32:29.337 SERIAL « [ACK] (0x06) 09:32:29.339 SERIAL « 0x0104011301e8 (6 bytes) 09:32:29.339 SERIAL » [ACK] (0x06) 09:32:29.340 DRIVER « [RES] [SendData] was sent: true 09:32:30.600 SERIAL « 0x010700135600007fc2 (9 bytes) 09:32:30.600 SERIAL » [ACK] (0x06) 09:32:30.602 DRIVER « [REQ] [SendData] callback id: 86 transmit status: OK 09:32:30.622 SERIAL « 0x0110000400060a98803af3456dece268a5dd (18 bytes) 09:32:30.623 SERIAL » [ACK] (0x06) 09:32:30.624 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x3af3456dece268a5 09:32:30.631 SERIAL » 0x01240013061d98812e61d52f846080b3985cbfe2cb442c1ac1503aedc964d34da (38 bytes) 43cf12557e6 09:32:30.632 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 87 └─[SecurityCCCommandEncapsulation] │ nonce id: 58 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: System 09:32:30.636 SERIAL « [ACK] (0x06) 09:32:30.643 SERIAL « 0x0104011301e8 (6 bytes) 09:32:30.644 SERIAL » [ACK] (0x06) 09:32:30.645 DRIVER « [RES] [SendData] was sent: true 09:32:30.669 SERIAL « 0x0107001357000003bf (9 bytes) 09:32:30.669 SERIAL » [ACK] (0x06) 09:32:30.670 DRIVER « [REQ] [SendData] callback id: 87 transmit status: OK 09:32:30.691 SERIAL « 0x0108000400060298402f (10 bytes) 09:32:30.692 SERIAL » [ACK] (0x06) 09:32:30.693 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:32:30.701 SERIAL » 0x01110013060a9880692ca69c99779fef24002c (19 bytes) 09:32:30.702 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x692ca69c99779fef 09:32:30.704 SERIAL « [ACK] (0x06) 09:32:30.710 SERIAL « 0x0104011301e8 (6 bytes) 09:32:30.711 SERIAL » [ACK] (0x06) 09:32:30.712 DRIVER « [RES] [SendData] was sent: true 09:32:30.755 SERIAL « 0x012700040006219881fb02c6ff1401589afe2cd92fe98ee5c3c20b2f9d38b4697 (41 bytes) e9c75f24652c1823c 09:32:30.756 SERIAL » [ACK] (0x06) 09:32:30.758 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: System notification status: 255 notification event: Unknown (0xfe) 09:32:30.763 SERIAL » 0x010a001313037005022558fc (12 bytes) 09:32:30.764 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 88 └─[ConfigurationCCGet] parameter #: 2 09:32:30.765 CNTRLR [Node 006] [~] [Notification] System[unknown]: 254 => 254 [Endpoint 1] 09:32:30.766 CNTRLR [Node 006] [~] [Notification] interviewComplete: true [Endpoint 1] [internal] => true 09:32:30.816 SERIAL « [ACK] (0x06) 09:32:30.820 SERIAL « 0x0104011301e8 (6 bytes) 09:32:30.820 SERIAL » [ACK] (0x06) 09:32:30.822 DRIVER « [RES] [SendData] was sent: true 09:32:30.824 SERIAL « 0x0107001358000005b6 (9 bytes) 09:32:30.825 SERIAL » [ACK] (0x06) 09:32:30.826 CNTRLR [Node 006] ProtectionCC: doing a partial interview... 09:32:30.826 CNTRLR » [Node 006] querying protection status... 09:32:30.830 DRIVER « [REQ] [SendData] callback id: 88 transmit status: OK 09:32:32.434 CNTRLR [Node 019] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:32:32.853 SERIAL « 0x01090004001b03300300d9 (11 bytes) 09:32:32.854 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:32:32.854 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:32:32.855 SERIAL » [ACK] (0x06) 09:32:32.856 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:32:32.907 SERIAL « 0x01090004001b03200100cb (11 bytes) 09:32:32.907 SERIAL » [ACK] (0x06) 09:32:32.908 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:32:32.909 CNTRLR [Node 027] treating BasicCC Set as a report 09:32:32.910 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:32:32.936 SERIAL » 0x010a001313037005022558fc (12 bytes) 09:32:32.937 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 88 └─[ConfigurationCCGet] parameter #: 2 09:32:32.938 SERIAL « [ACK] (0x06) 09:32:32.945 SERIAL « 0x0104011301e8 (6 bytes) 09:32:32.945 SERIAL » [ACK] (0x06) 09:32:32.945 DRIVER « [RES] [SendData] was sent: true 09:32:32.991 SERIAL « 0x0107001358000006b5 (9 bytes) 09:32:32.991 SERIAL » [ACK] (0x06) 09:32:32.992 DRIVER « [REQ] [SendData] callback id: 88 transmit status: OK 09:32:33.268 SERIAL « 0x010c0004000306310504220430d4 (14 bytes) 09:32:33.269 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:32:33.270 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 245.2 => 107.2 [Endpoint 0] 09:32:33.270 SERIAL » [ACK] (0x06) 09:32:33.272 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 107.2 09:32:34.269 SERIAL « 0x010c00040003063105042205f613 (14 bytes) 09:32:34.274 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:32:34.275 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 107.2 => 152.6 [Endpoint 0] 09:32:34.276 SERIAL » [ACK] (0x06) 09:32:34.278 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 152.6 09:32:34.595 CNTRLR [Node 019] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:32:35.101 SERIAL » 0x010a001313037005022558fc (12 bytes) 09:32:35.102 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 88 └─[ConfigurationCCGet] parameter #: 2 09:32:35.104 SERIAL « [ACK] (0x06) 09:32:35.110 SERIAL « 0x0104011301e8 (6 bytes) 09:32:35.111 SERIAL » [ACK] (0x06) 09:32:35.112 DRIVER « [RES] [SendData] was sent: true 09:32:35.157 SERIAL « 0x0107001358000005b6 (9 bytes) 09:32:35.158 SERIAL » [ACK] (0x06) 09:32:35.159 DRIVER « [REQ] [SendData] callback id: 88 transmit status: OK 09:32:35.269 SERIAL « 0x010c00040003063105042208bc54 (14 bytes) 09:32:35.271 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:32:35.272 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 152.6 => 223.6 [Endpoint 0] 09:32:35.285 SERIAL » [ACK] (0x06) 09:32:35.288 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 223.6 09:32:36.269 SERIAL « 0x010c0004000306310504220a648e (14 bytes) 09:32:36.270 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:32:36.272 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 223.6 => 266 [Endpoint 0] 09:32:36.273 SERIAL » [ACK] (0x06) 09:32:36.275 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 266 09:32:36.766 SERIAL » 0x010a001312036009022559e0 (12 bytes) 09:32:36.767 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 89 └─[MultiChannelCCCapabilityGet] endpoint: 2 09:32:36.767 CNTRLR « [Node 019] received no value for parameter #2 09:32:36.767 CNTRLR » [Node 019] querying parameter #3 value... 09:32:36.772 SERIAL « [ACK] (0x06) 09:32:36.774 SERIAL « 0x0104011301e8 (6 bytes) 09:32:36.775 SERIAL » [ACK] (0x06) 09:32:36.775 DRIVER « [RES] [SendData] was sent: true 09:32:36.823 SERIAL « 0x0107001359000006b4 (9 bytes) 09:32:36.824 SERIAL » [ACK] (0x06) 09:32:36.824 DRIVER « [REQ] [SendData] callback id: 89 transmit status: OK 09:32:36.913 SERIAL « 0x01160004001210600a0221015e8e31989f596c7180852222 (24 bytes) 09:32:36.913 CNTRLR [Node 018] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 2] [internal] 49,152,159,89,108,113,128,133,34 => 94,142,49,152,159,89,108,113,128,133,34 09:32:36.914 SERIAL » [ACK] (0x06) 09:32:36.914 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:32:36.919 SERIAL » 0x0109001306029840255a46 (11 bytes) 09:32:36.919 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 90 └─[SecurityCCNonceGet] 09:32:36.921 CNTRLR « [Node 018] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:32:36.922 CNTRLR [Node 018] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:32:36.952 SERIAL « [ACK] (0x06) 09:32:36.955 SERIAL « 0x0104011301e8 (6 bytes) 09:32:36.956 SERIAL » [ACK] (0x06) 09:32:36.957 DRIVER « [RES] [SendData] was sent: true 09:32:36.959 CNTRLR [Node 018] BatteryCC: doing a partial interview... 09:32:36.960 CNTRLR » [Node 018] querying battery status... 09:32:38.269 SERIAL « 0x010700135a00008637 (9 bytes) 09:32:38.270 SERIAL » [ACK] (0x06) 09:32:38.272 DRIVER « [REQ] [SendData] callback id: 90 transmit status: OK 09:32:38.292 SERIAL « 0x0110000400060a9880091e53618de085083a (18 bytes) 09:32:38.293 SERIAL » [ACK] (0x06) 09:32:38.295 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x091e53618de08508 09:32:38.304 SERIAL » 0x01210013061a98812a649c3b1998748dc4748f088a131e098fb6a5a74d93ab8e2 (35 bytes) 55b5e 09:32:38.305 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 91 └─[SecurityCCCommandEncapsulation] │ nonce id: 9 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 09:32:38.308 SERIAL « [ACK] (0x06) 09:32:38.315 SERIAL « 0x0104011301e8 (6 bytes) 09:32:38.316 SERIAL » [ACK] (0x06) 09:32:38.317 DRIVER « [RES] [SendData] was sent: true 09:32:38.347 SERIAL « 0x010700135b000003b3 (9 bytes) 09:32:38.347 SERIAL » [ACK] (0x06) 09:32:38.349 DRIVER « [REQ] [SendData] callback id: 91 transmit status: OK 09:32:38.458 SERIAL « 0x0108000400060298402f (10 bytes) 09:32:38.459 SERIAL » [ACK] (0x06) 09:32:38.459 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:32:38.464 SERIAL » 0x01110013060a9880b4dafc217046c04c2400c4 (19 bytes) 09:32:38.465 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xb4dafc217046c04c 09:32:38.466 SERIAL « [ACK] (0x06) 09:32:38.473 SERIAL « 0x0104011301e8 (6 bytes) 09:32:38.473 SERIAL » [ACK] (0x06) 09:32:38.474 DRIVER « [RES] [SendData] was sent: true 09:32:38.515 SERIAL « 0x0121000400061b988124135c1a58a5e1edd106d44898aad4a3b488e99bffe7ca2 (35 bytes) 74aa1 09:32:38.516 SERIAL » [ACK] (0x06) 09:32:38.517 CNTRLR [Node 006] [~] [Protection] local: 0 => 0 [Endpoint 1] 09:32:38.518 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ProtectionCCReport] local: Unprotected 09:32:38.521 SERIAL » 0x010a00131303700503255cf9 (12 bytes) 09:32:38.522 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 92 └─[ConfigurationCCGet] parameter #: 3 09:32:38.522 CNTRLR « [Node 006] received protection status: local: Unprotected 09:32:38.523 CNTRLR [Node 006] [~] [Protection] interviewComplete: true => [Endpoint 1] [internal] true 09:32:38.553 SERIAL « [ACK] (0x06) 09:32:38.556 SERIAL « 0x0104011301e8 (6 bytes) 09:32:38.557 SERIAL » [ACK] (0x06) 09:32:38.558 DRIVER « [RES] [SendData] was sent: true 09:32:38.560 CNTRLR [Node 006] BatteryCC: doing a partial interview... [Endpoint 1] 09:32:38.561 CNTRLR » [Node 006] querying battery status... [Endpoint 1] 09:32:38.577 SERIAL « 0x010700135c000005b2 (9 bytes) 09:32:38.577 SERIAL » [ACK] (0x06) 09:32:38.577 DRIVER « [REQ] [SendData] callback id: 92 transmit status: OK 09:32:38.628 SERIAL « 0x010b0004001305700603010092 (13 bytes) 09:32:38.633 CNTRLR [Node 019] [~] [Configuration] 3: 0 => 0 09:32:38.634 SERIAL » [ACK] (0x06) 09:32:38.638 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 09:32:38.642 SERIAL » 0x0109001312028002255d0f (11 bytes) 09:32:38.642 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 93 └─[BatteryCCGet] 09:32:38.643 CNTRLR « [Node 019] parameter #3 has value: 0 09:32:38.643 CNTRLR » [Node 019] querying parameter #10 value... 09:32:38.647 SERIAL « [ACK] (0x06) 09:32:38.651 SERIAL « 0x0104011301e8 (6 bytes) 09:32:38.651 SERIAL » [ACK] (0x06) 09:32:38.652 DRIVER « [RES] [SendData] was sent: true 09:32:38.755 SERIAL « 0x010700135d00000bbd (9 bytes) 09:32:38.755 SERIAL » [ACK] (0x06) 09:32:38.755 DRIVER « [REQ] [SendData] callback id: 93 transmit status: OK 09:32:40.358 CNTRLR [Node 018] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:32:40.384 CNTRLR [Node 020] Beginning interview - last completed stage: RestartFromCache 09:32:40.385 CNTRLR » [Node 020] pinging the node... 09:32:40.863 SERIAL » 0x0109001312028002255d0f (11 bytes) 09:32:40.864 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 93 └─[BatteryCCGet] 09:32:40.866 SERIAL « [ACK] (0x06) 09:32:40.872 SERIAL « 0x0104011301e8 (6 bytes) 09:32:40.873 SERIAL » [ACK] (0x06) 09:32:40.874 DRIVER « [RES] [SendData] was sent: true 09:32:40.920 SERIAL « 0x010700135d000005b3 (9 bytes) 09:32:40.921 SERIAL » [ACK] (0x06) 09:32:40.922 DRIVER « [REQ] [SendData] callback id: 93 transmit status: OK 09:32:42.526 CNTRLR [Node 018] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:32:43.032 SERIAL » 0x0109001312028002255d0f (11 bytes) 09:32:43.033 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 93 └─[BatteryCCGet] 09:32:43.034 SERIAL « [ACK] (0x06) 09:32:43.040 SERIAL « 0x0104011301e8 (6 bytes) 09:32:43.041 SERIAL » [ACK] (0x06) 09:32:43.041 DRIVER « [RES] [SendData] was sent: true 09:32:43.088 SERIAL « 0x010700135d000005b3 (9 bytes) 09:32:43.088 SERIAL » [ACK] (0x06) 09:32:43.089 DRIVER « [REQ] [SendData] callback id: 93 transmit status: OK 09:32:44.693 SERIAL » 0x01080013140100255e8a (10 bytes) 09:32:44.694 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 94 └─[NoOperationCC] 09:32:44.694 CNTRLR [Node 018] Battery status query timed out - skipping because it is not critica l... 09:32:44.694 CNTRLR [Node 018] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:32:44.726 SERIAL « [ACK] (0x06) 09:32:44.730 SERIAL « 0x0104011301e8 (6 bytes) 09:32:44.730 SERIAL » [ACK] (0x06) 09:32:44.731 DRIVER « [RES] [SendData] was sent: true 09:32:44.735 CNTRLR [Node 018] ZWavePlusCC: doing a partial interview... [Endpoint 1] 09:32:44.736 CNTRLR [Node 018] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 09:32:44.736 CNTRLR [Node 018] ThermostatModeCC: doing a partial interview... [Endpoint 1] 09:32:44.736 CNTRLR » [Node 018] querying current thermostat mode... [Endpoint 1] 09:32:44.739 SERIAL « 0x010700135e000002b7 (9 bytes) 09:32:44.739 SERIAL » [ACK] (0x06) 09:32:44.740 DRIVER « [REQ] [SendData] callback id: 94 transmit status: OK 09:32:44.749 SERIAL » 0x0109001306029840255f43 (11 bytes) 09:32:44.749 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 95 └─[SecurityCCNonceGet] 09:32:44.749 CNTRLR « [Node 020] ping successful 09:32:44.751 CNTRLR [Node 020] ManufacturerSpecificCC: doing a partial interview... 09:32:44.752 CNTRLR [Node 020] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:32:44.752 CNTRLR [Node 020] VersionCC: doing a partial interview... 09:32:44.753 CNTRLR [Node 020] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:32:44.753 CNTRLR [Node 020] trying to load device config 09:32:44.755 SERIAL « [ACK] (0x06) 09:32:44.766 CNTRLR [Node 020] device config loaded 09:32:44.766 CNTRLR [Node 020] WakeUpCC: doing a complete interview... 09:32:44.766 CNTRLR » [Node 020] retrieving wakeup interval from the device... 09:32:44.769 SERIAL « 0x0104011301e8 (6 bytes) 09:32:44.769 SERIAL » [ACK] (0x06) 09:32:44.770 DRIVER « [RES] [SendData] was sent: true 09:32:45.992 SERIAL « 0x010700135f00007cc8 (9 bytes) 09:32:45.993 SERIAL » [ACK] (0x06) 09:32:45.993 DRIVER « [REQ] [SendData] callback id: 95 transmit status: OK 09:32:46.015 SERIAL « 0x0110000400060a98800608ad0ae200f7f4b7 (18 bytes) 09:32:46.015 SERIAL » [ACK] (0x06) 09:32:46.016 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x0608ad0ae200f7f4 09:32:46.019 SERIAL » 0x01210013061a9881c2e79db0d9e7b736637c4c2375c26b068887c70ceb6fc1a62 (35 bytes) 560b7 09:32:46.020 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 96 └─[SecurityCCCommandEncapsulation] │ nonce id: 6 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BatteryCCGet] 09:32:46.023 SERIAL « [ACK] (0x06) 09:32:46.030 SERIAL « 0x0104011301e8 (6 bytes) 09:32:46.030 SERIAL » [ACK] (0x06) 09:32:46.031 DRIVER « [RES] [SendData] was sent: true 09:32:46.055 SERIAL « 0x010700136000000388 (9 bytes) 09:32:46.055 SERIAL » [ACK] (0x06) 09:32:46.056 DRIVER « [REQ] [SendData] callback id: 96 transmit status: OK 09:32:46.172 SERIAL « 0x0108000400060298402f (10 bytes) 09:32:46.173 SERIAL » [ACK] (0x06) 09:32:46.173 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:32:46.180 SERIAL » 0x01110013060a9880f72fae653e4734fc24006f (19 bytes) 09:32:46.180 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xf72fae653e4734fc 09:32:46.182 SERIAL « [ACK] (0x06) 09:32:46.189 SERIAL « 0x0104011301e8 (6 bytes) 09:32:46.189 SERIAL » [ACK] (0x06) 09:32:46.190 DRIVER « [RES] [SendData] was sent: true 09:32:46.231 SERIAL « 0x0121000400061b98811d9d3c8e60cd73a840de59a5955dfd89f74597f7b44def5 (35 bytes) f0dd2 09:32:46.232 SERIAL » [ACK] (0x06) 09:32:46.233 CNTRLR [Node 006] [~] [Battery] level: 89 => 89 [Endpoint 1] 09:32:46.234 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 1] 09:32:46.235 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BatteryCCReport] level: 89 is low: false 09:32:46.238 SERIAL » 0x0109001314028405256136 (11 bytes) 09:32:46.238 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 97 └─[WakeUpCCIntervalGet] 09:32:46.239 CNTRLR « [Node 006] received response for battery information: [Endpoint 1] level: 89 09:32:46.240 CNTRLR [Node 006] [~] [Battery] interviewComplete: true => tr [Endpoint 1] [internal] ue 09:32:46.273 SERIAL « [ACK] (0x06) 09:32:46.274 SERIAL « 0x0104011301e8 (6 bytes) 09:32:46.274 SERIAL » [ACK] (0x06) 09:32:46.276 DRIVER « [RES] [SendData] was sent: true 09:32:46.278 SERIAL « 0x010700136100000288 (9 bytes) 09:32:46.278 SERIAL » [ACK] (0x06) 09:32:46.279 DRIVER « [REQ] [SendData] callback id: 97 transmit status: OK 09:32:46.427 CNTRLR [Node 006] ClockCC: doing a partial interview... 09:32:46.428 CNTRLR » [Node 006] requesting current clock setting... 09:32:47.881 CNTRLR [Node 020] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:32:48.386 SERIAL » 0x0109001314028405256136 (11 bytes) 09:32:48.387 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 97 └─[WakeUpCCIntervalGet] 09:32:48.390 SERIAL « [ACK] (0x06) 09:32:48.396 SERIAL « 0x0104011301e8 (6 bytes) 09:32:48.396 SERIAL » [ACK] (0x06) 09:32:48.397 DRIVER « [RES] [SendData] was sent: true 09:32:48.413 SERIAL « 0x010700136100000288 (9 bytes) 09:32:48.413 SERIAL » [ACK] (0x06) 09:32:48.415 DRIVER « [REQ] [SendData] callback id: 97 transmit status: OK 09:32:50.018 CNTRLR [Node 020] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:32:50.524 SERIAL » 0x0109001314028405256136 (11 bytes) 09:32:50.525 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 97 └─[WakeUpCCIntervalGet] 09:32:50.527 SERIAL « [ACK] (0x06) 09:32:50.533 SERIAL « 0x0104011301e8 (6 bytes) 09:32:50.534 SERIAL » [ACK] (0x06) 09:32:50.535 DRIVER « [RES] [SendData] was sent: true 09:32:50.551 SERIAL « 0x010700136100000389 (9 bytes) 09:32:50.551 SERIAL » [ACK] (0x06) 09:32:50.553 DRIVER « [REQ] [SendData] callback id: 97 transmit status: OK 09:32:52.162 SERIAL » 0x010a0013130370050a2562ce (12 bytes) 09:32:52.163 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 98 └─[ConfigurationCCGet] parameter #: 10 09:32:52.164 CNTRLR [Node 020] Failed all interview attempts, giving up. 09:32:52.166 SERIAL « [ACK] (0x06) 09:32:52.172 SERIAL « 0x0104011301e8 (6 bytes) 09:32:52.172 SERIAL » [ACK] (0x06) 09:32:52.173 DRIVER « [RES] [SendData] was sent: true 09:32:52.218 SERIAL « 0x01070013620000058c (9 bytes) 09:32:52.219 SERIAL » [ACK] (0x06) 09:32:52.220 DRIVER « [REQ] [SendData] callback id: 98 transmit status: OK 09:32:52.271 SERIAL « 0x010b000400130570060a01019a (13 bytes) 09:32:52.281 CNTRLR [Node 019] [~] [Configuration] 10: 1 => 1 09:32:52.283 SERIAL » [ACK] (0x06) 09:32:52.284 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 1 09:32:52.290 SERIAL » 0x010d00131206600d0001400225639d (15 bytes) 09:32:52.290 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 99 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:32:52.291 CNTRLR « [Node 019] parameter #10 has value: 1 09:32:52.291 CNTRLR » [Node 019] querying parameter #12 value... 09:32:52.297 SERIAL « [ACK] (0x06) 09:32:52.299 SERIAL « 0x0104011301e8 (6 bytes) 09:32:52.299 SERIAL » [ACK] (0x06) 09:32:52.301 DRIVER « [RES] [SendData] was sent: true 09:32:52.388 SERIAL « 0x010700136300000981 (9 bytes) 09:32:52.389 SERIAL » [ACK] (0x06) 09:32:52.390 DRIVER « [REQ] [SendData] callback id: 99 transmit status: OK 09:32:53.993 CNTRLR [Node 018] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:32:54.499 SERIAL » 0x010d00131206600d0001400225639d (15 bytes) 09:32:54.500 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 99 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:32:54.501 SERIAL « [ACK] (0x06) 09:32:54.508 SERIAL « 0x0104011301e8 (6 bytes) 09:32:54.508 SERIAL » [ACK] (0x06) 09:32:54.509 DRIVER « [RES] [SendData] was sent: true 09:32:54.557 SERIAL « 0x01070013630000058d (9 bytes) 09:32:54.557 SERIAL » [ACK] (0x06) 09:32:54.558 DRIVER « [REQ] [SendData] callback id: 99 transmit status: OK 09:32:56.160 CNTRLR [Node 018] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:32:56.663 SERIAL » 0x010d00131206600d0001400225639d (15 bytes) 09:32:56.664 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 99 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:32:56.666 SERIAL « [ACK] (0x06) 09:32:56.672 SERIAL « 0x0104011301e8 (6 bytes) 09:32:56.672 SERIAL » [ACK] (0x06) 09:32:56.673 DRIVER « [RES] [SendData] was sent: true 09:32:56.721 SERIAL « 0x01070013630000068e (9 bytes) 09:32:56.722 SERIAL » [ACK] (0x06) 09:32:56.722 DRIVER « [REQ] [SendData] callback id: 99 transmit status: OK 09:32:58.340 SERIAL » 0x0109001306029840256478 (11 bytes) 09:32:58.341 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 100 └─[SecurityCCNonceGet] 09:32:58.342 CNTRLR [Node 018] Interview attempt 2/5 failed, retrying in 10000 ms... 09:32:58.345 SERIAL « [ACK] (0x06) 09:32:58.349 SERIAL « 0x0104011301e8 (6 bytes) 09:32:58.349 SERIAL » [ACK] (0x06) 09:32:58.350 DRIVER « [RES] [SendData] was sent: true 09:32:59.645 SERIAL « 0x01070013640000820d (9 bytes) 09:32:59.645 SERIAL » [ACK] (0x06) 09:32:59.646 DRIVER « [REQ] [SendData] callback id: 100 transmit status: OK 09:32:59.667 SERIAL « 0x0110000400060a9880d5473d041f041486dd (18 bytes) 09:32:59.668 SERIAL » [ACK] (0x06) 09:32:59.670 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xd5473d041f041486 09:32:59.677 SERIAL » 0x01210013061a9881072d55aa1e53b9cffc8e577465e267d590a8265046e2b43d2 (35 bytes) 56561 09:32:59.679 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 101 └─[SecurityCCCommandEncapsulation] │ nonce id: 213 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ClockCCGet] 09:32:59.682 SERIAL « [ACK] (0x06) 09:32:59.689 SERIAL « 0x0104011301e8 (6 bytes) 09:32:59.690 SERIAL » [ACK] (0x06) 09:32:59.691 DRIVER « [RES] [SendData] was sent: true 09:32:59.714 SERIAL « 0x01070013650000038d (9 bytes) 09:32:59.715 SERIAL » [ACK] (0x06) 09:32:59.716 DRIVER « [REQ] [SendData] callback id: 101 transmit status: OK 09:32:59.832 SERIAL « 0x0108000400060298402f (10 bytes) 09:32:59.833 SERIAL » [ACK] (0x06) 09:32:59.834 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:32:59.848 SERIAL » 0x01110013060a98805dde804603f6dffe24005c (19 bytes) 09:32:59.849 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x5dde804603f6dffe 09:32:59.852 SERIAL « [ACK] (0x06) 09:32:59.858 SERIAL « 0x0104011301e8 (6 bytes) 09:32:59.859 SERIAL » [ACK] (0x06) 09:32:59.860 DRIVER « [RES] [SendData] was sent: true 09:32:59.901 SERIAL « 0x0122000400061c98818a1d0575a90184aa52e84b1d87ddbba8ba5dc791d8b8d9a (36 bytes) aee2371 09:32:59.902 SERIAL » [ACK] (0x06) 09:32:59.905 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ClockCCReport] clock setting: Sunday, 09:26 09:32:59.913 SERIAL » 0x010a0013130370050c2566cc (12 bytes) 09:32:59.914 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 102 └─[ConfigurationCCGet] parameter #: 12 09:32:59.915 CNTRLR « [Node 006] received current clock setting: Sunday, 09:26 09:32:59.916 CNTRLR [Node 006] [~] [Clock] interviewComplete: true => true [Endpoint 1] [internal] 09:32:59.961 SERIAL « [ACK] (0x06) 09:32:59.964 SERIAL « 0x0104011301e8 (6 bytes) 09:32:59.964 SERIAL » [ACK] (0x06) 09:32:59.965 DRIVER « [RES] [SendData] was sent: true 09:32:59.969 CNTRLR [Node 006] ZWavePlusCC: doing a partial interview... [Endpoint 2] 09:32:59.970 CNTRLR [Node 006] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 09:32:59.970 CNTRLR [Node 006] MultilevelSensorCC: doing a partial interview... [Endpoint 2] 09:32:59.970 CNTRLR » [Node 006] querying Air temperature sensor reading... [Endpoint 2] 09:32:59.973 SERIAL « 0x010700136600000588 (9 bytes) 09:32:59.974 SERIAL » [ACK] (0x06) 09:32:59.974 DRIVER « [REQ] [SendData] callback id: 102 transmit status: OK 09:33:00.022 SERIAL « 0x010c000400130670060c0200960c (14 bytes) 09:33:00.028 CNTRLR [Node 019] [~] [Configuration] 12: 150 => 150 09:33:00.029 SERIAL » [ACK] (0x06) 09:33:00.030 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 150 09:33:00.043 SERIAL » 0x010900130602984025677b (11 bytes) 09:33:00.044 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 103 └─[SecurityCCNonceGet] 09:33:00.044 CNTRLR « [Node 019] parameter #12 has value: 150 09:33:00.045 CNTRLR » [Node 019] querying parameter #13 value... 09:33:00.049 SERIAL « [ACK] (0x06) 09:33:00.055 SERIAL « 0x0104011301e8 (6 bytes) 09:33:00.056 SERIAL » [ACK] (0x06) 09:33:00.057 DRIVER « [RES] [SendData] was sent: true 09:33:00.148 SERIAL « 0x010700136700000884 (9 bytes) 09:33:00.149 SERIAL » [ACK] (0x06) 09:33:00.152 DRIVER « [REQ] [SendData] callback id: 103 transmit status: OK 09:33:00.155 SERIAL « 0x0110000400060a98801ed7ca912a0d2aa7c7 (18 bytes) 09:33:00.155 SERIAL » [ACK] (0x06) 09:33:00.156 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x1ed7ca912a0d2aa7 09:33:00.164 SERIAL » 0x01230013061c98814c4d73f16f6cb09b20e8d5a76d94f051451e92004d084c850 (37 bytes) 598256810 09:33:00.165 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 104 └─[SecurityCCCommandEncapsulation] │ nonce id: 30 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:33:00.168 SERIAL « [ACK] (0x06) 09:33:00.176 SERIAL « 0x0104011301e8 (6 bytes) 09:33:00.176 SERIAL » [ACK] (0x06) 09:33:00.177 DRIVER « [RES] [SendData] was sent: true 09:33:00.201 SERIAL « 0x010700136800000380 (9 bytes) 09:33:00.202 SERIAL » [ACK] (0x06) 09:33:00.202 DRIVER « [REQ] [SendData] callback id: 104 transmit status: OK 09:33:00.294 SERIAL « 0x0108000400060298402f (10 bytes) 09:33:00.295 SERIAL » [ACK] (0x06) 09:33:00.295 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:33:00.300 SERIAL » 0x01110013060a988095dbe0c3f93b84532400b5 (19 bytes) 09:33:00.300 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x95dbe0c3f93b8453 09:33:00.302 SERIAL « [ACK] (0x06) 09:33:00.309 SERIAL « 0x0104011301e8 (6 bytes) 09:33:00.309 SERIAL » [ACK] (0x06) 09:33:00.310 DRIVER « [RES] [SendData] was sent: true 09:33:00.352 SERIAL « 0x0124000400061e98812bb047ba4deae336358ee6f026b6b47c1f92e2952e0b6a6 (38 bytes) 4666f903e49 09:33:00.353 SERIAL » [ACK] (0x06) 09:33:00.354 CNTRLR [Node 006] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:33:00.355 CNTRLR [Node 006] [~] [Multilevel Sensor] Air temperature: 21.4 => 21.8 [Endpoint 2] 09:33:00.356 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 21.8 09:33:00.359 SERIAL » 0x010a0013130370050d2569c2 (12 bytes) 09:33:00.359 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 105 └─[ConfigurationCCGet] parameter #: 13 09:33:00.360 CNTRLR « [Node 006] received current Air temperature sensor reading: 21.8 [Endpoint 2] °C 09:33:00.360 CNTRLR [Node 006] [~] [Multilevel Sensor] interviewComplete: [Endpoint 2] [internal] true => true 09:33:00.396 SERIAL « [ACK] (0x06) 09:33:00.397 SERIAL « 0x0104011301e8 (6 bytes) 09:33:00.397 SERIAL » [ACK] (0x06) 09:33:00.398 DRIVER « [RES] [SendData] was sent: true 09:33:00.400 CNTRLR [Node 006] NotificationCC: doing a partial interview... [Endpoint 2] 09:33:00.401 CNTRLR » [Node 006] querying notification status for Power Management... [Endpoint 2] 09:33:00.413 SERIAL « 0x010700136900000587 (9 bytes) 09:33:00.414 SERIAL » [ACK] (0x06) 09:33:00.414 DRIVER « [REQ] [SendData] callback id: 105 transmit status: OK 09:33:00.466 SERIAL « 0x010b000400130570060d01019d (13 bytes) 09:33:00.471 CNTRLR [Node 019] [~] [Configuration] 13: 1 => 1 09:33:00.472 SERIAL » [ACK] (0x06) 09:33:00.473 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 1 09:33:00.477 SERIAL » 0x0109001306029840256a76 (11 bytes) 09:33:00.478 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 106 └─[SecurityCCNonceGet] 09:33:00.478 CNTRLR « [Node 019] parameter #13 has value: 1 09:33:00.478 CNTRLR » [Node 019] querying parameter #14 value... 09:33:00.482 SERIAL « [ACK] (0x06) 09:33:00.489 SERIAL « 0x0104011301e8 (6 bytes) 09:33:00.489 SERIAL » [ACK] (0x06) 09:33:00.489 DRIVER « [RES] [SendData] was sent: true 09:33:00.579 SERIAL « 0x010700136a00000889 (9 bytes) 09:33:00.580 SERIAL » [ACK] (0x06) 09:33:00.582 DRIVER « [REQ] [SendData] callback id: 106 transmit status: OK 09:33:00.584 SERIAL « 0x0110000400060a9880c6a07b2e2ba9445852 (18 bytes) 09:33:00.585 SERIAL » [ACK] (0x06) 09:33:00.586 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xc6a07b2e2ba94458 09:33:00.589 SERIAL » 0x01240013061d9881c7efd53725a166a9f1b6efaddb885cd00aa0c6d83cea66baf (38 bytes) 5e1e1256b94 09:33:00.589 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 107 └─[SecurityCCCommandEncapsulation] │ nonce id: 198 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: Power Management 09:33:00.592 SERIAL « [ACK] (0x06) 09:33:00.600 SERIAL « 0x0104011301e8 (6 bytes) 09:33:00.600 SERIAL » [ACK] (0x06) 09:33:00.600 DRIVER « [RES] [SendData] was sent: true 09:33:00.626 SERIAL « 0x010700136b00000383 (9 bytes) 09:33:00.626 SERIAL » [ACK] (0x06) 09:33:00.626 DRIVER « [REQ] [SendData] callback id: 107 transmit status: OK 09:33:00.648 SERIAL « 0x0108000400060298402f (10 bytes) 09:33:00.649 SERIAL » [ACK] (0x06) 09:33:00.650 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:33:00.658 SERIAL » 0x01110013060a9880960e2454d79e709c240080 (19 bytes) 09:33:00.658 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x960e2454d79e709c 09:33:00.661 SERIAL « [ACK] (0x06) 09:33:00.667 SERIAL « 0x0104011301e8 (6 bytes) 09:33:00.668 SERIAL » [ACK] (0x06) 09:33:00.669 DRIVER « [RES] [SendData] was sent: true 09:33:00.712 SERIAL « 0x012700040006219881ca52539e283a3015342c8273bc7af724f9586182810f961 (41 bytes) a67b83081238b30ca 09:33:00.713 SERIAL » [ACK] (0x06) 09:33:00.715 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 09:33:00.720 SERIAL » 0x010a0013130370050e256cc4 (12 bytes) 09:33:00.721 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 108 └─[ConfigurationCCGet] parameter #: 14 09:33:00.722 CNTRLR [Node 006] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 2] 54 09:33:00.723 CNTRLR » [Node 006] querying notification status for System... [Endpoint 2] 09:33:00.729 SERIAL « [ACK] (0x06) 09:33:00.731 SERIAL « 0x0104011301e8 (6 bytes) 09:33:00.731 SERIAL » [ACK] (0x06) 09:33:00.733 DRIVER « [RES] [SendData] was sent: true 09:33:00.776 SERIAL « 0x010700136c00000582 (9 bytes) 09:33:00.776 SERIAL » [ACK] (0x06) 09:33:00.777 DRIVER « [REQ] [SendData] callback id: 108 transmit status: OK 09:33:00.828 SERIAL « 0x010b000400130570060e01009f (13 bytes) 09:33:00.834 CNTRLR [Node 019] [~] [Configuration] 14: 0 => 0 09:33:00.835 SERIAL » [ACK] (0x06) 09:33:00.836 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 0 09:33:00.840 SERIAL » 0x0109001306029840256d71 (11 bytes) 09:33:00.841 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 109 └─[SecurityCCNonceGet] 09:33:00.841 CNTRLR « [Node 019] parameter #14 has value: 0 09:33:00.841 CNTRLR » [Node 019] querying parameter #17 value... 09:33:00.845 SERIAL « [ACK] (0x06) 09:33:00.850 SERIAL « 0x0104011301e8 (6 bytes) 09:33:00.850 SERIAL » [ACK] (0x06) 09:33:00.851 DRIVER « [RES] [SendData] was sent: true 09:33:00.929 SERIAL « 0x010700136d0000088e (9 bytes) 09:33:00.930 SERIAL » [ACK] (0x06) 09:33:00.930 DRIVER « [REQ] [SendData] callback id: 109 transmit status: OK 09:33:00.952 SERIAL « 0x0110000400060a9880178f5d39d0d1848006 (18 bytes) 09:33:00.952 SERIAL » [ACK] (0x06) 09:33:00.953 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x178f5d39d0d18480 09:33:00.956 SERIAL » 0x01240013061d988139e809374f9687ce34d625b1761efec2315c1705cdbc67893 (38 bytes) 84dc5256e8c 09:33:00.957 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 110 └─[SecurityCCCommandEncapsulation] │ nonce id: 23 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:33:00.960 SERIAL « [ACK] (0x06) 09:33:00.967 SERIAL « 0x0104011301e8 (6 bytes) 09:33:00.967 SERIAL » [ACK] (0x06) 09:33:00.968 DRIVER « [RES] [SendData] was sent: true 09:33:00.993 SERIAL « 0x010700136e00000386 (9 bytes) 09:33:00.994 SERIAL » [ACK] (0x06) 09:33:00.994 DRIVER « [REQ] [SendData] callback id: 110 transmit status: OK 09:33:02.596 CNTRLR [Node 006] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:33:03.115 SERIAL » 0x0109001306029840256f73 (11 bytes) 09:33:03.116 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 111 └─[SecurityCCNonceGet] 09:33:03.118 SERIAL « [ACK] (0x06) 09:33:03.125 SERIAL « 0x0104011301e8 (6 bytes) 09:33:03.125 SERIAL » [ACK] (0x06) 09:33:03.126 DRIVER « [RES] [SendData] was sent: true 09:33:04.405 SERIAL « 0x010700136f00008105 (9 bytes) 09:33:04.406 SERIAL » [ACK] (0x06) 09:33:04.407 DRIVER « [REQ] [SendData] callback id: 111 transmit status: OK 09:33:04.427 SERIAL « 0x0110000400060a9880dee555ee639e3501b6 (18 bytes) 09:33:04.428 SERIAL » [ACK] (0x06) 09:33:04.430 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xdee555ee639e3501 09:33:04.437 SERIAL » 0x01240013061d9881236ff0b399c0969932cafa56a877a6a73bd1de2f125f57008 (38 bytes) 300a0256e70 09:33:04.438 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 110 └─[SecurityCCCommandEncapsulation] │ nonce id: 222 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:33:04.441 SERIAL « [ACK] (0x06) 09:33:04.448 SERIAL « 0x0104011301e8 (6 bytes) 09:33:04.449 SERIAL » [ACK] (0x06) 09:33:04.450 DRIVER « [RES] [SendData] was sent: true 09:33:04.475 SERIAL « 0x010700136e00000386 (9 bytes) 09:33:04.475 SERIAL » [ACK] (0x06) 09:33:04.476 DRIVER « [REQ] [SendData] callback id: 110 transmit status: OK 09:33:06.081 CNTRLR [Node 006] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:33:06.272 SERIAL « 0x010c000400030631050422090de4 (14 bytes) 09:33:06.273 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:33:06.274 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 266 => 231.7 [Endpoint 0] 09:33:06.274 SERIAL » [ACK] (0x06) 09:33:06.276 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 231.7 09:33:06.586 SERIAL » 0x010900130602984025706c (11 bytes) 09:33:06.586 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 112 └─[SecurityCCNonceGet] 09:33:06.588 SERIAL « [ACK] (0x06) 09:33:06.594 SERIAL « 0x0104011301e8 (6 bytes) 09:33:06.595 SERIAL » [ACK] (0x06) 09:33:06.595 DRIVER « [RES] [SendData] was sent: true 09:33:07.860 SERIAL « 0x01070013700000801b (9 bytes) 09:33:07.861 SERIAL » [ACK] (0x06) 09:33:07.862 DRIVER « [REQ] [SendData] callback id: 112 transmit status: OK 09:33:07.883 SERIAL « 0x0110000400060a988000f08319bc0cf16bbf (18 bytes) 09:33:07.884 SERIAL » [ACK] (0x06) 09:33:07.886 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x00f08319bc0cf16b 09:33:07.894 SERIAL » 0x01240013061d9881de86fd7768c2a51ab64bf0dfa24d28132d74007ccb15fe812 (38 bytes) a0f19256ef8 09:33:07.895 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 110 └─[SecurityCCCommandEncapsulation] │ nonce id: 0 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:33:07.900 SERIAL « [ACK] (0x06) 09:33:07.906 SERIAL « 0x0104011301e8 (6 bytes) 09:33:07.906 SERIAL » [ACK] (0x06) 09:33:07.907 DRIVER « [RES] [SendData] was sent: true 09:33:07.933 SERIAL « 0x010700136e00000386 (9 bytes) 09:33:07.933 SERIAL » [ACK] (0x06) 09:33:07.935 DRIVER « [REQ] [SendData] callback id: 110 transmit status: OK 09:33:08.272 SERIAL « 0x010c0004000306310504220752b5 (14 bytes) 09:33:08.275 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:33:08.277 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 231.7 => 187.4 [Endpoint 0] 09:33:08.278 SERIAL » [ACK] (0x06) 09:33:08.282 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 187.4 09:33:08.343 CNTRLR [Node 018] Beginning interview - last completed stage: RestartFromCache 09:33:08.344 CNTRLR » [Node 018] pinging the node... 09:33:09.547 SERIAL » 0x010800131201002571a3 (10 bytes) 09:33:09.547 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 113 └─[NoOperationCC] 09:33:09.548 CNTRLR [Node 006] Interview attempt 3/5 failed, retrying in 15000 ms... 09:33:09.549 SERIAL « [ACK] (0x06) 09:33:09.555 SERIAL « 0x0104011301e8 (6 bytes) 09:33:09.556 SERIAL » [ACK] (0x06) 09:33:09.556 DRIVER « [RES] [SendData] was sent: true 09:33:09.601 SERIAL « 0x01070013710000059f (9 bytes) 09:33:09.601 SERIAL » [ACK] (0x06) 09:33:09.602 DRIVER « [REQ] [SendData] callback id: 113 transmit status: OK 09:33:09.608 SERIAL » 0x010a001313037005112572c5 (12 bytes) 09:33:09.609 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 114 └─[ConfigurationCCGet] parameter #: 17 09:33:09.609 CNTRLR « [Node 018] ping successful 09:33:09.612 CNTRLR [Node 018] ManufacturerSpecificCC: doing a partial interview... 09:33:09.612 CNTRLR [Node 018] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:33:09.643 SERIAL « [ACK] (0x06) 09:33:09.646 SERIAL « 0x0104011301e8 (6 bytes) 09:33:09.646 SERIAL » [ACK] (0x06) 09:33:09.647 DRIVER « [RES] [SendData] was sent: true 09:33:09.650 CNTRLR [Node 018] VersionCC: doing a partial interview... 09:33:09.650 CNTRLR [Node 018] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:33:09.650 CNTRLR [Node 018] trying to load device config 09:33:09.655 CNTRLR [Node 018] device config loaded 09:33:09.656 CNTRLR [Node 018] ZWavePlusCC: doing a partial interview... 09:33:09.656 CNTRLR [Node 018] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:33:09.657 CNTRLR » [Node 018] querying device endpoint information... 09:33:09.663 SERIAL « 0x01070013720000059c (9 bytes) 09:33:09.664 SERIAL » [ACK] (0x06) 09:33:09.664 DRIVER « [REQ] [SendData] callback id: 114 transmit status: OK 09:33:09.715 SERIAL « 0x010b0004001305700611010a8a (13 bytes) 09:33:09.720 CNTRLR [Node 019] [~] [Configuration] 17: 10 => 10 09:33:09.721 SERIAL » [ACK] (0x06) 09:33:09.722 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 17 value size: 1 value: 10 09:33:09.725 SERIAL » 0x01090013120260072573c4 (11 bytes) 09:33:09.726 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 115 └─[MultiChannelCCEndPointGet] 09:33:09.726 CNTRLR « [Node 019] parameter #17 has value: 10 09:33:09.726 CNTRLR » [Node 019] querying parameter #18 value... 09:33:09.732 SERIAL « [ACK] (0x06) 09:33:09.734 SERIAL « 0x0104011301e8 (6 bytes) 09:33:09.736 SERIAL » [ACK] (0x06) 09:33:09.737 DRIVER « [RES] [SendData] was sent: true 09:33:09.838 SERIAL « 0x010700137300000b93 (9 bytes) 09:33:09.838 SERIAL » [ACK] (0x06) 09:33:09.839 DRIVER « [REQ] [SendData] callback id: 115 transmit status: OK 09:33:09.917 SERIAL « 0x010b000400120560080002008d (13 bytes) 09:33:09.918 CNTRLR [Node 018] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:33:09.918 CNTRLR [Node 018] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 09:33:09.919 CNTRLR [Node 018] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:33:09.919 CNTRLR [Node 018] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 09:33:09.919 SERIAL » [ACK] (0x06) 09:33:09.920 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:33:09.923 SERIAL » 0x010a001313037005122574c0 (12 bytes) 09:33:09.924 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 116 └─[ConfigurationCCGet] parameter #: 18 09:33:09.924 CNTRLR « [Node 018] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:33:09.925 CNTRLR » [Node 018] querying all endpoints... 09:33:09.929 SERIAL « [ACK] (0x06) 09:33:09.933 SERIAL « 0x0104011301e8 (6 bytes) 09:33:09.933 SERIAL » [ACK] (0x06) 09:33:09.935 DRIVER « [RES] [SendData] was sent: true 09:33:10.036 SERIAL « 0x010700137400000b94 (9 bytes) 09:33:10.036 SERIAL » [ACK] (0x06) 09:33:10.036 DRIVER « [REQ] [SendData] callback id: 116 transmit status: OK 09:33:10.089 SERIAL « 0x010b0004001305700612010a89 (13 bytes) 09:33:10.094 CNTRLR [Node 019] [~] [Configuration] 18: 10 => 10 09:33:10.095 SERIAL » [ACK] (0x06) 09:33:10.096 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 18 value size: 1 value: 10 09:33:10.098 SERIAL » 0x010b00131204600bffff2575ca (13 bytes) 09:33:10.099 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 117 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:33:10.099 CNTRLR « [Node 019] parameter #18 has value: 10 09:33:10.100 CNTRLR » [Node 019] querying parameter #22 value... 09:33:10.103 SERIAL « [ACK] (0x06) 09:33:10.108 SERIAL « 0x0104011301e8 (6 bytes) 09:33:10.108 SERIAL » [ACK] (0x06) 09:33:10.109 DRIVER « [RES] [SendData] was sent: true 09:33:10.209 SERIAL « 0x010700137500000a94 (9 bytes) 09:33:10.209 SERIAL » [ACK] (0x06) 09:33:10.210 DRIVER « [REQ] [SendData] callback id: 117 transmit status: OK 09:33:10.288 SERIAL « 0x010d0004001207600c00ffff01028c (15 bytes) 09:33:10.291 SERIAL » [ACK] (0x06) 09:33:10.293 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 09:33:10.298 SERIAL » 0x010a001313037005162576c6 (12 bytes) 09:33:10.299 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 118 └─[ConfigurationCCGet] parameter #: 22 09:33:10.299 CNTRLR « [Node 018] received endpoints: 1, 2 09:33:10.299 CNTRLR » [Node 018] querying capabilities for endpoint #1... 09:33:10.304 SERIAL « [ACK] (0x06) 09:33:10.308 SERIAL « 0x0104011301e8 (6 bytes) 09:33:10.308 SERIAL » [ACK] (0x06) 09:33:10.309 DRIVER « [RES] [SendData] was sent: true 09:33:10.406 SERIAL « 0x010700137600000a97 (9 bytes) 09:33:10.407 SERIAL » [ACK] (0x06) 09:33:10.408 DRIVER « [REQ] [SendData] callback id: 118 transmit status: OK 09:33:10.459 SERIAL « 0x010c00040013067006160200f070 (14 bytes) 09:33:10.472 CNTRLR [Node 019] [~] [Configuration] 22: 240 => 240 09:33:10.473 SERIAL » [ACK] (0x06) 09:33:10.475 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 240 09:33:10.481 SERIAL » 0x010a001312036009012577cd (12 bytes) 09:33:10.482 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 119 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:33:10.483 CNTRLR « [Node 019] parameter #22 has value: 240 09:33:10.483 CNTRLR » [Node 019] querying parameter #29 value... 09:33:10.490 SERIAL « [ACK] (0x06) 09:33:10.494 SERIAL « 0x0104011301e8 (6 bytes) 09:33:10.495 SERIAL » [ACK] (0x06) 09:33:10.496 DRIVER « [RES] [SendData] was sent: true 09:33:10.578 SERIAL « 0x010700137700000995 (9 bytes) 09:33:10.579 SERIAL » [ACK] (0x06) 09:33:10.579 DRIVER « [REQ] [SendData] callback id: 119 transmit status: OK 09:33:10.665 SERIAL « 0x011a0004001214600a0108065e8e404353989f596c71758081852292 (28 bytes) 09:33:10.666 CNTRLR [Node 018] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 1] [internal] 64,67,83,152,159,89,108,113,117,128,129,133,34 => 94,142,64,67,83,152,159,89,1 08,113,117,128,129,133,34 09:33:10.667 SERIAL » [ACK] (0x06) 09:33:10.668 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:33:10.680 SERIAL » 0x010a0013130370051d2578c3 (12 bytes) 09:33:10.681 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 120 └─[ConfigurationCCGet] parameter #: 29 09:33:10.681 CNTRLR « [Node 018] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:33:10.682 CNTRLR » [Node 018] querying capabilities for endpoint #2... 09:33:10.690 SERIAL « [ACK] (0x06) 09:33:10.692 SERIAL « 0x0104011301e8 (6 bytes) 09:33:10.693 SERIAL » [ACK] (0x06) 09:33:10.694 DRIVER « [RES] [SendData] was sent: true 09:33:10.776 SERIAL « 0x01070013780000099a (9 bytes) 09:33:10.776 SERIAL » [ACK] (0x06) 09:33:10.777 DRIVER « [REQ] [SendData] callback id: 120 transmit status: OK 09:33:10.829 SERIAL « 0x010b000400130570061d01008c (13 bytes) 09:33:10.842 CNTRLR [Node 019] [~] [Configuration] 29: 0 => 0 09:33:10.843 SERIAL » [ACK] (0x06) 09:33:10.845 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 29 value size: 1 value: 0 09:33:10.856 SERIAL » 0x010a001312036009022579c0 (12 bytes) 09:33:10.857 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 121 └─[MultiChannelCCCapabilityGet] endpoint: 2 09:33:10.858 CNTRLR « [Node 019] parameter #29 has value: 0 09:33:10.858 CNTRLR » [Node 019] querying parameter #30 value... 09:33:10.866 SERIAL « [ACK] (0x06) 09:33:10.870 SERIAL « 0x0104011301e8 (6 bytes) 09:33:10.871 SERIAL » [ACK] (0x06) 09:33:10.875 DRIVER « [RES] [SendData] was sent: true 09:33:10.948 SERIAL « 0x01070013790000089a (9 bytes) 09:33:10.949 SERIAL » [ACK] (0x06) 09:33:10.949 DRIVER « [REQ] [SendData] callback id: 121 transmit status: OK 09:33:11.033 SERIAL « 0x01160004001210600a0221015e8e31989f596c7180852222 (24 bytes) 09:33:11.034 CNTRLR [Node 018] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 2] [internal] 49,152,159,89,108,113,128,133,34 => 94,142,49,152,159,89,108,113,128,133,34 09:33:11.035 SERIAL » [ACK] (0x06) 09:33:11.037 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:33:11.043 SERIAL » 0x010a0013130370051e257ac2 (12 bytes) 09:33:11.044 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 122 └─[ConfigurationCCGet] parameter #: 30 09:33:11.045 CNTRLR « [Node 018] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:33:11.046 CNTRLR [Node 018] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:33:11.117 SERIAL « [ACK] (0x06) 09:33:11.124 SERIAL « 0x0104011301e8 (6 bytes) 09:33:11.124 SERIAL » [ACK] (0x06) 09:33:11.125 DRIVER « [RES] [SendData] was sent: true 09:33:11.127 CNTRLR [Node 018] BatteryCC: doing a partial interview... 09:33:11.128 CNTRLR » [Node 018] querying battery status... 09:33:11.146 SERIAL « 0x010700137a00000a9b (9 bytes) 09:33:11.146 SERIAL » [ACK] (0x06) 09:33:11.147 DRIVER « [REQ] [SendData] callback id: 122 transmit status: OK 09:33:11.199 SERIAL « 0x010b000400130570061e01028d (13 bytes) 09:33:11.204 CNTRLR [Node 019] [~] [Configuration] 30: 2 => 2 09:33:11.205 SERIAL » [ACK] (0x06) 09:33:11.206 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 2 09:33:11.209 SERIAL » 0x0109001312028002257b29 (11 bytes) 09:33:11.209 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 123 └─[BatteryCCGet] 09:33:11.209 CNTRLR « [Node 019] parameter #30 has value: 2 09:33:11.210 CNTRLR » [Node 019] querying parameter #31 value... 09:33:11.217 SERIAL « [ACK] (0x06) 09:33:11.219 SERIAL « 0x0104011301e8 (6 bytes) 09:33:11.219 SERIAL » [ACK] (0x06) 09:33:11.220 DRIVER « [RES] [SendData] was sent: true 09:33:11.316 SERIAL « 0x010700137b00000a9a (9 bytes) 09:33:11.316 SERIAL » [ACK] (0x06) 09:33:11.317 DRIVER « [REQ] [SendData] callback id: 123 transmit status: OK 09:33:12.919 CNTRLR [Node 018] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:33:13.422 SERIAL » 0x0109001312028002257b29 (11 bytes) 09:33:13.422 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 123 └─[BatteryCCGet] 09:33:13.424 SERIAL « [ACK] (0x06) 09:33:13.430 SERIAL « 0x0104011301e8 (6 bytes) 09:33:13.430 SERIAL » [ACK] (0x06) 09:33:13.431 DRIVER « [RES] [SendData] was sent: true 09:33:13.479 SERIAL « 0x010700137b00000595 (9 bytes) 09:33:13.479 SERIAL » [ACK] (0x06) 09:33:13.480 DRIVER « [REQ] [SendData] callback id: 123 transmit status: OK 09:33:15.084 CNTRLR [Node 018] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:33:15.588 SERIAL » 0x0109001312028002257b29 (11 bytes) 09:33:15.589 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 123 └─[BatteryCCGet] 09:33:15.590 SERIAL « [ACK] (0x06) 09:33:15.599 SERIAL « 0x0104011301e8 (6 bytes) 09:33:15.599 SERIAL » [ACK] (0x06) 09:33:15.600 DRIVER « [RES] [SendData] was sent: true 09:33:15.645 SERIAL « 0x010700137b00000595 (9 bytes) 09:33:15.645 SERIAL » [ACK] (0x06) 09:33:15.646 DRIVER « [REQ] [SendData] callback id: 123 transmit status: OK 09:33:17.250 SERIAL » 0x010a0013130370051f257cc5 (12 bytes) 09:33:17.251 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 124 └─[ConfigurationCCGet] parameter #: 31 09:33:17.251 CNTRLR [Node 018] Battery status query timed out - skipping because it is not critica l... 09:33:17.252 CNTRLR [Node 018] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:33:17.278 SERIAL « [ACK] (0x06) 09:33:17.281 SERIAL « 0x0104011301e8 (6 bytes) 09:33:17.282 SERIAL » [ACK] (0x06) 09:33:17.288 DRIVER « [RES] [SendData] was sent: true 09:33:17.292 CNTRLR [Node 018] ZWavePlusCC: doing a partial interview... [Endpoint 1] 09:33:17.292 CNTRLR [Node 018] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 09:33:17.293 CNTRLR [Node 018] ThermostatModeCC: doing a partial interview... [Endpoint 1] 09:33:17.293 CNTRLR » [Node 018] querying current thermostat mode... [Endpoint 1] 09:33:17.306 SERIAL « 0x010700137c00000592 (9 bytes) 09:33:17.307 SERIAL » [ACK] (0x06) 09:33:17.307 DRIVER « [REQ] [SendData] callback id: 124 transmit status: OK 09:33:17.357 SERIAL « 0x010b000400130570061f01008e (13 bytes) 09:33:17.363 CNTRLR [Node 019] [~] [Configuration] 31: 0 => 0 09:33:17.364 SERIAL » [ACK] (0x06) 09:33:17.365 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 0 09:33:17.368 SERIAL » 0x010d00131206600d00014002257d83 (15 bytes) 09:33:17.368 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 125 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:33:17.369 CNTRLR « [Node 019] parameter #31 has value: 0 09:33:17.369 CNTRLR » [Node 019] querying parameter #32 value... 09:33:17.379 SERIAL « [ACK] (0x06) 09:33:17.381 SERIAL « 0x0104011301e8 (6 bytes) 09:33:17.382 SERIAL » [ACK] (0x06) 09:33:17.384 DRIVER « [RES] [SendData] was sent: true 09:33:17.493 SERIAL « 0x010700137d00000a9c (9 bytes) 09:33:17.494 SERIAL » [ACK] (0x06) 09:33:17.497 DRIVER « [REQ] [SendData] callback id: 125 transmit status: OK 09:33:17.557 SERIAL « 0x010a000400120422010102c7 (12 bytes) 09:33:17.557 DRIVER Dropping message because it could not be deserialized: The command class Appli cation Status is not implemented 09:33:17.558 SERIAL » [ACK] (0x06) 09:33:19.101 CNTRLR [Node 018] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:33:19.607 SERIAL » 0x010d00131206600d00014002257d83 (15 bytes) 09:33:19.608 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 125 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:33:19.610 SERIAL « [ACK] (0x06) 09:33:19.616 SERIAL « 0x0104011301e8 (6 bytes) 09:33:19.617 SERIAL » [ACK] (0x06) 09:33:19.618 DRIVER « [RES] [SendData] was sent: true 09:33:19.666 SERIAL « 0x010700137d00000593 (9 bytes) 09:33:19.667 SERIAL » [ACK] (0x06) 09:33:19.668 DRIVER « [REQ] [SendData] callback id: 125 transmit status: OK 09:33:20.274 SERIAL « 0x010c000400030631050422088860 (14 bytes) 09:33:20.275 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:33:20.278 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 187.4 => 218.4 [Endpoint 0] 09:33:20.279 SERIAL » [ACK] (0x06) 09:33:20.283 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 218.4 09:33:21.272 CNTRLR [Node 018] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:33:21.780 SERIAL » 0x010d00131206600d00014002257d83 (15 bytes) 09:33:21.781 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 125 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:33:21.783 SERIAL « [ACK] (0x06) 09:33:21.789 SERIAL « 0x0104011301e8 (6 bytes) 09:33:21.790 SERIAL » [ACK] (0x06) 09:33:21.791 DRIVER « [RES] [SendData] was sent: true 09:33:21.839 SERIAL « 0x010700137d00000593 (9 bytes) 09:33:21.839 SERIAL » [ACK] (0x06) 09:33:21.840 DRIVER « [REQ] [SendData] callback id: 125 transmit status: OK 09:33:23.274 SERIAL « 0x010c000400030631050422057491 (14 bytes) 09:33:23.274 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:33:23.275 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 218.4 => 139.6 [Endpoint 0] 09:33:23.276 SERIAL » [ACK] (0x06) 09:33:23.278 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 139.6 09:33:23.448 SERIAL » 0x010a00131303700520257ef8 (12 bytes) 09:33:23.448 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 126 └─[ConfigurationCCGet] parameter #: 32 09:33:23.449 CNTRLR [Node 018] Interview attempt 3/5 failed, retrying in 15000 ms... 09:33:23.450 SERIAL « [ACK] (0x06) 09:33:23.456 SERIAL « 0x0104011301e8 (6 bytes) 09:33:23.457 SERIAL » [ACK] (0x06) 09:33:23.457 DRIVER « [RES] [SendData] was sent: true 09:33:23.503 SERIAL « 0x010700137e00000590 (9 bytes) 09:33:23.503 SERIAL » [ACK] (0x06) 09:33:23.504 DRIVER « [REQ] [SendData] callback id: 126 transmit status: OK 09:33:23.556 SERIAL « 0x010b00040013057006200101b0 (13 bytes) 09:33:23.561 CNTRLR [Node 019] [~] [Configuration] 32: 1 => 1 09:33:23.562 SERIAL » [ACK] (0x06) 09:33:23.563 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 1 value: 1 09:33:23.566 SERIAL » 0x01080013150100257faa (10 bytes) 09:33:23.567 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 127 └─[NoOperationCC] 09:33:23.567 CNTRLR « [Node 019] parameter #32 has value: 1 09:33:23.567 CNTRLR » [Node 019] querying parameter #33 value... 09:33:23.571 SERIAL « [ACK] (0x06) 09:33:23.577 SERIAL « 0x0104011301e8 (6 bytes) 09:33:23.577 SERIAL » [ACK] (0x06) 09:33:23.578 DRIVER « [RES] [SendData] was sent: true 09:33:24.548 CNTRLR [Node 006] Beginning interview - last completed stage: RestartFromCache 09:33:24.549 CNTRLR » [Node 006] pinging the node... 09:33:24.776 SERIAL « 0x010c00040003063105042208ef07 (14 bytes) 09:33:24.777 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:33:24.778 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 139.6 => 228.7 [Endpoint 0] 09:33:24.778 SERIAL » [ACK] (0x06) 09:33:24.779 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 228.7 09:33:31.067 SERIAL « 0x010700137f0102ee79 (9 bytes) 09:33:31.067 SERIAL » [ACK] (0x06) 09:33:31.068 DRIVER « [REQ] [SendData] callback id: 127 transmit status: NoAck 09:33:31.078 SERIAL » 0x01080013160100258056 (10 bytes) 09:33:31.079 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 128 └─[NoOperationCC] 09:33:31.079 CNTRLR [Node 021] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 09:33:31.080 CNTRLR [Node 021] The node is asleep. 09:33:31.082 CNTRLR [Node 021] The node is ready to be used 09:33:31.085 CNTRLR [Node 021] ping failed: Failed to send the command after 1 attempts (Status No Ack) 09:33:31.089 CNTRLR [Node 021] ManufacturerSpecificCC: doing a partial interview... 09:33:31.090 CNTRLR [Node 021] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:33:31.158 SERIAL « [ACK] (0x06) 09:33:31.160 SERIAL « 0x0104011301e8 (6 bytes) 09:33:31.160 SERIAL » [ACK] (0x06) 09:33:31.161 DRIVER « [RES] [SendData] was sent: true 09:33:31.164 CNTRLR [Node 021] VersionCC: doing a partial interview... 09:33:31.165 CNTRLR [Node 021] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:33:31.165 CNTRLR [Node 021] trying to load device config 09:33:31.177 CNTRLR [Node 021] device config loaded 09:33:31.177 CNTRLR [Node 021] BatteryCC: doing a partial interview... 09:33:31.177 CNTRLR » [Node 021] querying battery status... 09:33:32.497 SERIAL « 0x010700138000008de6 (9 bytes) 09:33:32.497 SERIAL » [ACK] (0x06) 09:33:32.498 DRIVER « [REQ] [SendData] callback id: 128 transmit status: OK 09:33:32.504 SERIAL » 0x01080013170100258156 (10 bytes) 09:33:32.504 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 129 └─[NoOperationCC] 09:33:32.505 CNTRLR « [Node 022] ping successful 09:33:32.507 CNTRLR [Node 022] ManufacturerSpecificCC: doing a partial interview... 09:33:32.509 CNTRLR [Node 022] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:33:32.537 SERIAL « [ACK] (0x06) 09:33:32.540 SERIAL « 0x0104011301e8 (6 bytes) 09:33:32.540 SERIAL » [ACK] (0x06) 09:33:32.541 DRIVER « [RES] [SendData] was sent: true 09:33:32.544 CNTRLR [Node 022] VersionCC: doing a partial interview... 09:33:32.544 CNTRLR [Node 022] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:33:32.545 CNTRLR [Node 022] trying to load device config 09:33:32.550 CNTRLR [Node 022] device config loaded 09:33:32.550 CNTRLR [Node 022] ZWavePlusCC: doing a partial interview... 09:33:32.551 CNTRLR [Node 022] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:33:32.551 CNTRLR » [Node 022] querying device endpoint information... 09:33:32.608 SERIAL « 0x010700138100000a60 (9 bytes) 09:33:32.608 SERIAL » [ACK] (0x06) 09:33:32.609 DRIVER « [REQ] [SendData] callback id: 129 transmit status: OK 09:33:32.616 SERIAL » 0x0108001318010025825a (10 bytes) 09:33:32.617 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 130 └─[NoOperationCC] 09:33:32.617 CNTRLR « [Node 023] ping successful 09:33:32.619 CNTRLR [Node 023] ManufacturerSpecificCC: doing a partial interview... 09:33:32.620 CNTRLR [Node 023] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:33:32.620 CNTRLR [Node 023] VersionCC: doing a partial interview... 09:33:32.621 CNTRLR [Node 023] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:33:32.621 CNTRLR [Node 023] trying to load device config 09:33:32.627 SERIAL « [ACK] (0x06) 09:33:32.629 SERIAL « 0x0104011301e8 (6 bytes) 09:33:32.629 SERIAL » [ACK] (0x06) 09:33:32.631 DRIVER « [RES] [SendData] was sent: true 09:33:32.658 CNTRLR [Node 023] device config loaded 09:33:32.658 CNTRLR » [Node 023] querying device endpoint information... 09:33:32.661 SERIAL « 0x01070013820000026b (9 bytes) 09:33:32.662 SERIAL » [ACK] (0x06) 09:33:32.663 DRIVER « [REQ] [SendData] callback id: 130 transmit status: OK 09:33:32.668 SERIAL » 0x0108001319010025835a (10 bytes) 09:33:32.668 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 131 └─[NoOperationCC] 09:33:32.669 CNTRLR « [Node 024] ping successful 09:33:32.672 CNTRLR [Node 024] ManufacturerSpecificCC: doing a partial interview... 09:33:32.672 CNTRLR [Node 024] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:33:32.673 CNTRLR [Node 024] VersionCC: doing a partial interview... 09:33:32.673 CNTRLR [Node 024] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:33:32.673 CNTRLR [Node 024] trying to load device config 09:33:32.678 SERIAL « [ACK] (0x06) 09:33:32.679 SERIAL « 0x0104011301e8 (6 bytes) 09:33:32.679 SERIAL » [ACK] (0x06) 09:33:32.680 DRIVER « [RES] [SendData] was sent: true 09:33:32.710 CNTRLR [Node 024] device config loaded 09:33:32.750 SERIAL « 0x01070013830000026a (9 bytes) 09:33:32.750 SERIAL » [ACK] (0x06) 09:33:32.755 DRIVER « [REQ] [SendData] callback id: 131 transmit status: OK 09:33:32.762 SERIAL » 0x010800131a010025845e (10 bytes) 09:33:32.763 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 132 └─[NoOperationCC] 09:33:32.763 CNTRLR « [Node 025] ping successful 09:33:32.764 CNTRLR [Node 025] ManufacturerSpecificCC: doing a partial interview... 09:33:32.764 CNTRLR [Node 025] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:33:32.765 CNTRLR [Node 025] VersionCC: doing a partial interview... 09:33:32.765 CNTRLR [Node 025] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:33:32.765 CNTRLR [Node 025] trying to load device config 09:33:32.769 CNTRLR [Node 024] ZWavePlusCC: doing a partial interview... 09:33:32.769 CNTRLR [Node 024] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:33:32.770 CNTRLR » [Node 024] querying device endpoint information... 09:33:32.771 SERIAL « [ACK] (0x06) 09:33:32.773 SERIAL « 0x0104011301e8 (6 bytes) 09:33:32.773 SERIAL » [ACK] (0x06) 09:33:32.774 DRIVER « [RES] [SendData] was sent: true 09:33:32.787 CNTRLR [Node 025] device config loaded 09:33:32.787 CNTRLR » [Node 025] querying device endpoint information... 09:33:32.789 SERIAL « 0x01070013840000026d (9 bytes) 09:33:32.790 SERIAL » [ACK] (0x06) 09:33:32.790 DRIVER « [REQ] [SendData] callback id: 132 transmit status: OK 09:33:32.794 SERIAL » 0x01080013060100258543 (10 bytes) 09:33:32.795 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 133 └─[NoOperationCC] 09:33:32.795 CNTRLR « [Node 026] ping successful 09:33:32.796 CNTRLR [Node 026] ManufacturerSpecificCC: doing a partial interview... 09:33:32.797 CNTRLR [Node 026] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:33:32.797 CNTRLR [Node 026] VersionCC: doing a partial interview... 09:33:32.797 CNTRLR [Node 026] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:33:32.797 CNTRLR [Node 026] trying to load device config 09:33:32.803 SERIAL « [ACK] (0x06) 09:33:32.804 SERIAL « 0x0104011301e8 (6 bytes) 09:33:32.804 SERIAL » [ACK] (0x06) 09:33:32.805 DRIVER « [RES] [SendData] was sent: true 09:33:32.813 CNTRLR [Node 026] device config loaded 09:33:32.814 CNTRLR [Node 026] AssociationCC: doing a partial interview... 09:33:32.814 CNTRLR [Node 026] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 09:33:32.814 CNTRLR [Node 026] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:33:32.815 CNTRLR [Node 026] BinarySwitchCC: doing a partial interview... 09:33:32.815 CNTRLR » [Node 026] querying Binary Switch state... 09:33:34.037 SERIAL « 0x010700138500007c12 (9 bytes) 09:33:34.038 SERIAL » [ACK] (0x06) 09:33:34.040 DRIVER « [REQ] [SendData] callback id: 133 transmit status: OK 09:33:34.058 SERIAL » 0x0109001317026007258634 (11 bytes) 09:33:34.058 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 134 └─[MultiChannelCCEndPointGet] 09:33:34.059 CNTRLR « [Node 006] ping successful 09:33:34.116 SERIAL « [ACK] (0x06) 09:33:34.122 SERIAL « 0x0104011301e8 (6 bytes) 09:33:34.122 SERIAL » [ACK] (0x06) 09:33:34.123 DRIVER « [RES] [SendData] was sent: true 09:33:34.134 CNTRLR [Node 006] ManufacturerSpecificCC: doing a partial interview... 09:33:34.135 CNTRLR [Node 006] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:33:34.136 CNTRLR [Node 006] VersionCC: doing a partial interview... 09:33:34.136 CNTRLR [Node 006] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:33:34.136 CNTRLR [Node 006] trying to load device config 09:33:34.140 CNTRLR [Node 006] device config loaded 09:33:34.141 CNTRLR [Node 006] ZWavePlusCC: doing a partial interview... 09:33:34.141 CNTRLR [Node 006] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:33:34.141 CNTRLR » [Node 006] querying device endpoint information... 09:33:34.162 SERIAL « 0x010700138600000a67 (9 bytes) 09:33:34.162 SERIAL » [ACK] (0x06) 09:33:34.162 DRIVER « [REQ] [SendData] callback id: 134 transmit status: OK 09:33:34.336 SERIAL « 0x010a000400170460084002c8 (12 bytes) 09:33:34.337 CNTRLR [Node 023] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:33:34.337 CNTRLR [Node 023] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 09:33:34.337 CNTRLR [Node 023] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:33:34.338 SERIAL » [ACK] (0x06) 09:33:34.338 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:33:34.341 SERIAL » 0x010900131902600725873b (11 bytes) 09:33:34.342 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 135 └─[MultiChannelCCEndPointGet] 09:33:34.343 CNTRLR « [Node 023] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:33:34.343 CNTRLR [Node 023] does not support EndPointFind, assuming that endpoints are sequenti al 09:33:34.343 CNTRLR » [Node 023] querying capabilities for endpoint #1... 09:33:34.346 SERIAL « [ACK] (0x06) 09:33:34.350 SERIAL « 0x0104011301e8 (6 bytes) 09:33:34.350 SERIAL » [ACK] (0x06) 09:33:34.351 DRIVER « [RES] [SendData] was sent: true 09:33:34.426 SERIAL « 0x010700138700000864 (9 bytes) 09:33:34.426 SERIAL » [ACK] (0x06) 09:33:34.427 DRIVER « [REQ] [SendData] callback id: 135 transmit status: OK 09:33:34.436 SERIAL « 0x010a000400190460084002c6 (12 bytes) 09:33:34.441 CNTRLR [Node 025] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:33:34.441 CNTRLR [Node 025] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 09:33:34.442 CNTRLR [Node 025] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:33:34.442 SERIAL » [ACK] (0x06) 09:33:34.443 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:33:34.446 SERIAL » 0x010a00131703600901258837 (12 bytes) 09:33:34.447 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 136 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:33:34.447 CNTRLR « [Node 025] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:33:34.450 CNTRLR [Node 025] does not support EndPointFind, assuming that endpoints are sequenti al 09:33:34.450 CNTRLR » [Node 025] querying capabilities for endpoint #1... 09:33:34.453 SERIAL « [ACK] (0x06) 09:33:34.455 SERIAL « 0x0104011301e8 (6 bytes) 09:33:34.455 SERIAL » [ACK] (0x06) 09:33:34.456 DRIVER « [RES] [SendData] was sent: true 09:33:34.551 SERIAL « 0x010700138800000a69 (9 bytes) 09:33:34.552 SERIAL » [ACK] (0x06) 09:33:34.552 DRIVER « [REQ] [SendData] callback id: 136 transmit status: OK 09:33:35.275 SERIAL « 0x010c000400030631050422047591 (14 bytes) 09:33:35.279 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:33:35.281 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 228.7 => 114.1 [Endpoint 0] 09:33:35.283 SERIAL » [ACK] (0x06) 09:33:35.286 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 114.1 09:33:36.155 CNTRLR [Node 023] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:33:36.275 SERIAL « 0x010c00040003063105042205c520 (14 bytes) 09:33:36.277 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:33:36.278 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 114.1 => 147.7 [Endpoint 0] 09:33:36.279 SERIAL » [ACK] (0x06) 09:33:36.281 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 147.7 09:33:36.660 SERIAL » 0x010a00131703600901258837 (12 bytes) 09:33:36.661 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 136 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:33:36.663 SERIAL « [ACK] (0x06) 09:33:36.669 SERIAL « 0x0104011301e8 (6 bytes) 09:33:36.670 SERIAL » [ACK] (0x06) 09:33:36.671 DRIVER « [RES] [SendData] was sent: true 09:33:36.766 SERIAL « 0x010700138800000a69 (9 bytes) 09:33:36.766 SERIAL » [ACK] (0x06) 09:33:36.767 DRIVER « [REQ] [SendData] callback id: 136 transmit status: OK 09:33:37.012 SERIAL « 0x010c0004001706600a01100125b9 (14 bytes) 09:33:37.013 CNTRLR [Node 023] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 1] [internal] 7 09:33:37.014 SERIAL » [ACK] (0x06) 09:33:37.014 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:33:37.018 SERIAL » 0x010a00131903600901258938 (12 bytes) 09:33:37.018 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 137 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:33:37.019 CNTRLR « [Node 023] received response for endpoint capabilities (#1): generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:33:37.019 CNTRLR [Node 023] all endpoints idendical, skipping capability query for endpoint #2. .. 09:33:37.020 CNTRLR [Node 023] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 2] [internal] 7 09:33:37.020 CNTRLR [Node 023] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:33:37.050 SERIAL « [ACK] (0x06) 09:33:37.054 SERIAL « 0x0104011301e8 (6 bytes) 09:33:37.055 SERIAL » [ACK] (0x06) 09:33:37.056 DRIVER « [RES] [SendData] was sent: true 09:33:37.059 CNTRLR [Node 023] WakeUpCC: doing a complete interview... 09:33:37.059 CNTRLR » [Node 023] retrieving wakeup interval from the device... 09:33:37.106 SERIAL « 0x01070013890000086a (9 bytes) 09:33:37.107 SERIAL » [ACK] (0x06) 09:33:37.108 DRIVER « [REQ] [SendData] callback id: 137 transmit status: OK 09:33:37.117 SERIAL « 0x010c0004001906600a01100125b7 (14 bytes) 09:33:37.118 CNTRLR [Node 025] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 1] [internal] 7 09:33:37.118 SERIAL » [ACK] (0x06) 09:33:37.120 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:33:37.129 SERIAL » 0x0109001317028405258ade (11 bytes) 09:33:37.132 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 138 └─[WakeUpCCIntervalGet] 09:33:37.133 CNTRLR « [Node 025] received response for endpoint capabilities (#1): generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:33:37.133 CNTRLR [Node 025] all endpoints idendical, skipping capability query for endpoint #2. .. 09:33:37.134 CNTRLR [Node 025] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 2] [internal] 7 09:33:37.138 CNTRLR [Node 025] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:33:37.139 CNTRLR [Node 025] WakeUpCC: doing a complete interview... 09:33:37.139 CNTRLR » [Node 025] retrieving wakeup interval from the device... 09:33:37.145 SERIAL « [ACK] (0x06) 09:33:37.147 SERIAL « 0x0104011301e8 (6 bytes) 09:33:37.147 SERIAL » [ACK] (0x06) 09:33:37.149 DRIVER « [RES] [SendData] was sent: true 09:33:37.237 SERIAL « 0x010700138a00000a6b (9 bytes) 09:33:37.237 SERIAL » [ACK] (0x06) 09:33:37.238 DRIVER « [REQ] [SendData] callback id: 138 transmit status: OK 09:33:38.276 SERIAL « 0x010c0004000306310504220a4fa5 (14 bytes) 09:33:38.277 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:33:38.279 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 147.7 => 263.9 [Endpoint 0] 09:33:38.280 SERIAL » [ACK] (0x06) 09:33:38.283 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 263.9 09:33:38.449 CNTRLR [Node 018] Beginning interview - last completed stage: RestartFromCache 09:33:38.450 CNTRLR » [Node 018] pinging the node... 09:33:38.841 CNTRLR [Node 023] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:33:39.276 SERIAL « 0x010c0004000306310504220534d1 (14 bytes) 09:33:39.277 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:33:39.279 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 263.9 => 133.2 [Endpoint 0] 09:33:39.280 SERIAL » [ACK] (0x06) 09:33:39.284 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 133.2 09:33:39.346 SERIAL » 0x0109001317028405258ade (11 bytes) 09:33:39.347 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 138 └─[WakeUpCCIntervalGet] 09:33:39.348 SERIAL « [ACK] (0x06) 09:33:39.355 SERIAL « 0x0104011301e8 (6 bytes) 09:33:39.355 SERIAL » [ACK] (0x06) 09:33:39.356 DRIVER « [RES] [SendData] was sent: true 09:33:39.451 SERIAL « 0x010700138a00000b6a (9 bytes) 09:33:39.452 SERIAL » [ACK] (0x06) 09:33:39.453 DRIVER « [REQ] [SendData] callback id: 138 transmit status: OK 09:33:40.274 SERIAL « 0x010c00040003063105042205fd18 (14 bytes) 09:33:40.275 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:33:40.293 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 133.2 => 153.3 [Endpoint 0] 09:33:40.295 SERIAL » [ACK] (0x06) 09:33:40.297 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 153.3 09:33:40.586 SERIAL « 0x0108000400060298402f (10 bytes) 09:33:40.587 SERIAL » [ACK] (0x06) 09:33:40.587 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:33:41.057 CNTRLR [Node 023] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:33:41.563 SERIAL » 0x0109001317028405258ade (11 bytes) 09:33:41.564 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 138 └─[WakeUpCCIntervalGet] 09:33:41.566 SERIAL « [ACK] (0x06) 09:33:41.572 SERIAL « 0x0104011301e8 (6 bytes) 09:33:41.573 SERIAL » [ACK] (0x06) 09:33:41.574 DRIVER « [RES] [SendData] was sent: true 09:33:41.668 SERIAL « 0x010700138a00000a6b (9 bytes) 09:33:41.669 SERIAL » [ACK] (0x06) 09:33:41.670 DRIVER « [REQ] [SendData] callback id: 138 transmit status: OK 09:33:43.277 SERIAL » 0x01110013060a9880e6ef1b5b7218a0fd2400b3 (19 bytes) 09:33:43.277 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xe6ef1b5b7218a0fd 09:33:43.278 CNTRLR [Node 023] Interview attempt 1/5 failed, retrying in 5000 ms... 09:33:43.279 SERIAL « [ACK] (0x06) 09:33:43.286 SERIAL « 0x0104011301e8 (6 bytes) 09:33:43.286 SERIAL » [ACK] (0x06) 09:33:43.286 DRIVER « [RES] [SendData] was sent: true 09:33:43.291 SERIAL » 0x01080013120100258b59 (10 bytes) 09:33:43.291 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 139 └─[NoOperationCC] 09:33:43.292 SERIAL « [ACK] (0x06) 09:33:43.299 SERIAL « 0x0104011301e8 (6 bytes) 09:33:43.299 SERIAL » [ACK] (0x06) 09:33:43.300 DRIVER « [RES] [SendData] was sent: true 09:33:43.347 SERIAL « 0x010700138b00000565 (9 bytes) 09:33:43.347 SERIAL » [ACK] (0x06) 09:33:43.348 DRIVER « [REQ] [SendData] callback id: 139 transmit status: OK 09:33:43.352 SERIAL » 0x0109001319028405258cd6 (11 bytes) 09:33:43.352 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 140 └─[WakeUpCCIntervalGet] 09:33:43.352 CNTRLR « [Node 018] ping successful 09:33:43.354 CNTRLR [Node 018] ManufacturerSpecificCC: doing a partial interview... 09:33:43.354 CNTRLR [Node 018] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:33:43.390 SERIAL « [ACK] (0x06) 09:33:43.393 SERIAL « 0x0104011301e8 (6 bytes) 09:33:43.394 SERIAL » [ACK] (0x06) 09:33:43.394 DRIVER « [RES] [SendData] was sent: true 09:33:43.396 SERIAL « 0x010700138c00000265 (9 bytes) 09:33:43.397 SERIAL » [ACK] (0x06) 09:33:43.397 CNTRLR [Node 018] VersionCC: doing a partial interview... 09:33:43.398 CNTRLR [Node 018] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:33:43.398 CNTRLR [Node 018] trying to load device config 09:33:43.400 DRIVER « [REQ] [SendData] callback id: 140 transmit status: OK 09:33:43.404 CNTRLR [Node 018] device config loaded 09:33:43.405 CNTRLR [Node 018] ZWavePlusCC: doing a partial interview... 09:33:43.405 CNTRLR [Node 018] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:33:43.406 CNTRLR » [Node 018] querying device endpoint information... 09:33:43.408 SERIAL « 0x0124000400061e9881e2ff0f2301d52b3df5530df63572217940e658e6eb72393 (38 bytes) c7662b4400b 09:33:43.409 SERIAL » [ACK] (0x06) 09:33:43.410 CNTRLR [Node 006] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:33:43.411 CNTRLR [Node 006] [~] [Multilevel Sensor] Air temperature: 21.8 => 21.8 [Endpoint 2] 09:33:43.412 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 21.8 09:33:43.497 SERIAL « 0x0108000400060298402f (10 bytes) 09:33:43.498 SERIAL » [ACK] (0x06) 09:33:43.498 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:33:45.003 CNTRLR [Node 025] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:33:45.510 SERIAL » 0x0109001319028405258cd6 (11 bytes) 09:33:45.510 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 140 └─[WakeUpCCIntervalGet] 09:33:45.513 SERIAL « [ACK] (0x06) 09:33:45.519 SERIAL « 0x0104011301e8 (6 bytes) 09:33:45.519 SERIAL » [ACK] (0x06) 09:33:45.521 DRIVER « [RES] [SendData] was sent: true 09:33:45.536 SERIAL « 0x010700138c00000265 (9 bytes) 09:33:45.537 SERIAL » [ACK] (0x06) 09:33:45.538 DRIVER « [REQ] [SendData] callback id: 140 transmit status: OK 09:33:47.156 CNTRLR [Node 025] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:33:47.660 SERIAL » 0x0109001319028405258cd6 (11 bytes) 09:33:47.660 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 140 └─[WakeUpCCIntervalGet] 09:33:47.662 SERIAL « [ACK] (0x06) 09:33:47.668 SERIAL « 0x0104011301e8 (6 bytes) 09:33:47.668 SERIAL » [ACK] (0x06) 09:33:47.669 DRIVER « [RES] [SendData] was sent: true 09:33:47.686 SERIAL « 0x010700138c00000265 (9 bytes) 09:33:47.686 SERIAL » [ACK] (0x06) 09:33:47.686 DRIVER « [REQ] [SendData] callback id: 140 transmit status: OK 09:33:48.278 CNTRLR [Node 023] Beginning interview - last completed stage: RestartFromCache 09:33:48.278 CNTRLR » [Node 023] pinging the node... 09:33:49.297 SERIAL » 0x01110013060a98803696b1de80cb03e62400ac (19 bytes) 09:33:49.298 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x3696b1de80cb03e6 09:33:49.299 CNTRLR [Node 025] Interview attempt 1/5 failed, retrying in 5000 ms... 09:33:49.301 SERIAL « [ACK] (0x06) 09:33:49.307 SERIAL « 0x0104011301e8 (6 bytes) 09:33:49.307 SERIAL » [ACK] (0x06) 09:33:49.308 DRIVER « [RES] [SendData] was sent: true 09:33:49.315 SERIAL » 0x01080013170100258d5a (10 bytes) 09:33:49.316 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 141 └─[NoOperationCC] 09:33:49.318 SERIAL « [ACK] (0x06) 09:33:49.324 SERIAL « 0x0104011301e8 (6 bytes) 09:33:49.325 SERIAL » [ACK] (0x06) 09:33:49.326 DRIVER « [RES] [SendData] was sent: true 09:33:49.388 SERIAL « 0x0124000400061e9881d2d081278e9950669fe459cceab585b6373a8d36a6aa595 (38 bytes) a69d4642a93 09:33:49.389 DRIVER Message with invalid data received. Dropping it: 0x0124000400061e9881d2d081278e9950669fe459cceab585b6373a8d36a6aa595a69d4642a93 09:33:49.389 SERIAL » [ACK] (0x06) 09:33:49.488 SERIAL « 0x010700138d00001177 (9 bytes) 09:33:49.489 SERIAL » [ACK] (0x06) 09:33:49.490 DRIVER « [REQ] [SendData] callback id: 141 transmit status: OK 09:33:49.501 SERIAL » 0x010a00131303700521258e09 (12 bytes) 09:33:49.502 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 142 └─[ConfigurationCCGet] parameter #: 33 09:33:49.502 CNTRLR « [Node 023] ping successful 09:33:49.504 CNTRLR [Node 023] ManufacturerSpecificCC: doing a partial interview... 09:33:49.505 CNTRLR [Node 023] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:33:49.566 SERIAL « [ACK] (0x06) 09:33:49.574 SERIAL « 0x0104011301e8 (6 bytes) 09:33:49.574 SERIAL » [ACK] (0x06) 09:33:49.577 DRIVER « [RES] [SendData] was sent: true 09:33:49.583 CNTRLR [Node 023] VersionCC: doing a partial interview... 09:33:49.583 CNTRLR [Node 023] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:33:49.584 CNTRLR [Node 023] trying to load device config 09:33:49.587 SERIAL « 0x010700138e00000560 (9 bytes) 09:33:49.587 SERIAL » [ACK] (0x06) 09:33:49.588 DRIVER « [REQ] [SendData] callback id: 142 transmit status: OK 09:33:49.614 CNTRLR [Node 023] device config loaded 09:33:49.614 CNTRLR » [Node 023] querying device endpoint information... 09:33:49.617 SERIAL « 0x010b00040013057006210101b1 (13 bytes) 09:33:49.622 CNTRLR [Node 019] [~] [Configuration] 33: 1 => 1 09:33:49.623 SERIAL » [ACK] (0x06) 09:33:49.624 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 1 value: 1 09:33:49.627 SERIAL » 0x0109001317026007258f3d (11 bytes) 09:33:49.628 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 143 └─[MultiChannelCCEndPointGet] 09:33:49.628 CNTRLR « [Node 019] parameter #33 has value: 1 09:33:49.628 CNTRLR » [Node 019] querying parameter #35 value... 09:33:49.632 SERIAL « [ACK] (0x06) 09:33:49.636 SERIAL « 0x0104011301e8 (6 bytes) 09:33:49.636 SERIAL » [ACK] (0x06) 09:33:49.646 DRIVER « [RES] [SendData] was sent: true 09:33:49.841 SERIAL « 0x010700138f00001571 (9 bytes) 09:33:49.841 SERIAL » [ACK] (0x06) 09:33:49.842 DRIVER « [REQ] [SendData] callback id: 143 transmit status: OK 09:33:49.946 SERIAL « 0x010a000400170460084002c8 (12 bytes) 09:33:49.947 CNTRLR [Node 023] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:33:49.947 CNTRLR [Node 023] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 09:33:49.948 CNTRLR [Node 023] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:33:49.948 SERIAL » [ACK] (0x06) 09:33:49.949 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:33:49.952 SERIAL » 0x0109001316026007259023 (11 bytes) 09:33:49.952 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 144 └─[MultiChannelCCEndPointGet] 09:33:49.953 CNTRLR « [Node 023] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:33:49.953 CNTRLR [Node 023] does not support EndPointFind, assuming that endpoints are sequenti al 09:33:49.953 CNTRLR » [Node 023] querying capabilities for endpoint #1... 09:33:49.956 SERIAL « [ACK] (0x06) 09:33:49.960 SERIAL « 0x0104011301e8 (6 bytes) 09:33:49.960 SERIAL » [ACK] (0x06) 09:33:49.961 DRIVER « [RES] [SendData] was sent: true 09:33:51.425 SERIAL « 0x0107001390000093e8 (9 bytes) 09:33:51.425 SERIAL » [ACK] (0x06) 09:33:51.426 DRIVER « [REQ] [SendData] callback id: 144 transmit status: OK 09:33:51.508 SERIAL « 0x010b0004001605600800020089 (13 bytes) 09:33:51.509 CNTRLR [Node 022] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:33:51.510 CNTRLR [Node 022] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 09:33:51.510 CNTRLR [Node 022] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:33:51.511 CNTRLR [Node 022] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 09:33:51.511 SERIAL » [ACK] (0x06) 09:33:51.513 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:33:51.520 SERIAL » 0x010a0013170360090125912e (12 bytes) 09:33:51.521 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 145 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:33:51.522 CNTRLR [Node 022] The node is alive. 09:33:51.524 CNTRLR [Node 022] The node is ready to be used 09:33:51.529 CNTRLR « [Node 022] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:33:51.529 CNTRLR » [Node 022] querying all endpoints... 09:33:51.538 SERIAL « [ACK] (0x06) 09:33:51.540 SERIAL « 0x0104011301e8 (6 bytes) 09:33:51.541 SERIAL » [ACK] (0x06) 09:33:51.542 DRIVER « [RES] [SendData] was sent: true 09:33:52.358 SERIAL « 0x01070013910000166c (9 bytes) 09:33:52.359 SERIAL » [ACK] (0x06) 09:33:52.360 DRIVER « [REQ] [SendData] callback id: 145 transmit status: OK 09:33:52.363 SERIAL « 0x010c0004001706600a01100125b9 (14 bytes) 09:33:52.364 CNTRLR [Node 023] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 1] [internal] 7 09:33:52.365 SERIAL » [ACK] (0x06) 09:33:52.366 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:33:52.370 SERIAL » 0x010900131802600725922f (11 bytes) 09:33:52.370 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 146 └─[MultiChannelCCEndPointGet] 09:33:52.371 CNTRLR « [Node 023] received response for endpoint capabilities (#1): generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:33:52.371 CNTRLR [Node 023] all endpoints idendical, skipping capability query for endpoint #2. .. 09:33:52.371 CNTRLR [Node 023] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 2] [internal] 7 09:33:52.372 CNTRLR [Node 023] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:33:52.399 SERIAL « [ACK] (0x06) 09:33:52.402 SERIAL « 0x0104011301e8 (6 bytes) 09:33:52.403 SERIAL » [ACK] (0x06) 09:33:52.404 DRIVER « [RES] [SendData] was sent: true 09:33:52.407 CNTRLR [Node 023] WakeUpCC: doing a complete interview... 09:33:52.407 CNTRLR » [Node 023] retrieving wakeup interval from the device... 09:33:52.411 SERIAL « 0x01070013920000027b (9 bytes) 09:33:52.411 SERIAL » [ACK] (0x06) 09:33:52.412 DRIVER « [REQ] [SendData] callback id: 146 transmit status: OK 09:33:52.415 SERIAL « 0x010b00040018056008400200c7 (13 bytes) 09:33:52.416 CNTRLR [Node 024] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:33:52.416 CNTRLR [Node 024] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 09:33:52.417 CNTRLR [Node 024] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:33:52.417 CNTRLR [Node 024] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 09:33:52.417 SERIAL » [ACK] (0x06) 09:33:52.418 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: true endpoint count (aggregated): 0 09:33:52.421 SERIAL » 0x01090013170284052593c7 (11 bytes) 09:33:52.422 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 147 └─[WakeUpCCIntervalGet] 09:33:52.422 CNTRLR [Node 024] The node is alive. 09:33:52.423 CNTRLR [Node 024] The node is ready to be used 09:33:52.424 CNTRLR « [Node 024] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: true endpoint count (aggregated): 0 09:33:52.424 CNTRLR » [Node 024] querying all endpoints... 09:33:52.432 SERIAL « [ACK] (0x06) 09:33:52.433 SERIAL « 0x0104011301e8 (6 bytes) 09:33:52.433 SERIAL » [ACK] (0x06) 09:33:52.434 DRIVER « [RES] [SendData] was sent: true 09:33:53.087 SERIAL « 0x010700139300000a72 (9 bytes) 09:33:53.087 SERIAL » [ACK] (0x06) 09:33:53.115 DRIVER « [REQ] [SendData] callback id: 147 transmit status: OK 09:33:54.277 SERIAL « 0x010c0004000306310504220acb21 (14 bytes) 09:33:54.277 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:33:54.278 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 153.3 => 276.3 [Endpoint 0] 09:33:54.279 SERIAL » [ACK] (0x06) 09:33:54.280 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 276.3 09:33:54.300 CNTRLR [Node 025] Beginning interview - last completed stage: RestartFromCache 09:33:54.300 CNTRLR » [Node 025] pinging the node... 09:33:54.718 CNTRLR [Node 023] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:33:55.221 SERIAL » 0x01090013170284052593c7 (11 bytes) 09:33:55.222 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 147 └─[WakeUpCCIntervalGet] 09:33:55.223 SERIAL « [ACK] (0x06) 09:33:55.229 SERIAL « 0x0104011301e8 (6 bytes) 09:33:55.230 SERIAL » [ACK] (0x06) 09:33:55.230 DRIVER « [RES] [SendData] was sent: true 09:33:55.326 SERIAL « 0x010700139300000a72 (9 bytes) 09:33:55.327 SERIAL » [ACK] (0x06) 09:33:55.327 DRIVER « [REQ] [SendData] callback id: 147 transmit status: OK 09:33:56.932 CNTRLR [Node 023] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:33:57.438 SERIAL » 0x01090013170284052593c7 (11 bytes) 09:33:57.438 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 147 └─[WakeUpCCIntervalGet] 09:33:57.440 SERIAL « [ACK] (0x06) 09:33:57.447 SERIAL « 0x0104011301e8 (6 bytes) 09:33:57.447 SERIAL » [ACK] (0x06) 09:33:57.448 DRIVER « [RES] [SendData] was sent: true 09:33:57.543 SERIAL « 0x010700139300000a72 (9 bytes) 09:33:57.544 SERIAL » [ACK] (0x06) 09:33:57.545 DRIVER « [REQ] [SendData] callback id: 147 transmit status: OK 09:33:59.154 SERIAL » 0x0108001319010025944d (10 bytes) 09:33:59.155 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 148 └─[NoOperationCC] 09:33:59.156 CNTRLR [Node 023] Interview attempt 2/5 failed, retrying in 10000 ms... 09:33:59.158 SERIAL « [ACK] (0x06) 09:33:59.163 SERIAL « 0x0104011301e8 (6 bytes) 09:33:59.164 SERIAL » [ACK] (0x06) 09:33:59.165 DRIVER « [RES] [SendData] was sent: true 09:33:59.181 SERIAL « 0x01070013940000037c (9 bytes) 09:33:59.181 SERIAL » [ACK] (0x06) 09:33:59.182 DRIVER « [REQ] [SendData] callback id: 148 transmit status: OK 09:33:59.190 SERIAL » 0x010900131a02250225956a (11 bytes) 09:33:59.191 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 149 └─[BinarySwitchCCGet] 09:33:59.192 CNTRLR « [Node 025] ping successful 09:33:59.200 CNTRLR [Node 025] ManufacturerSpecificCC: doing a partial interview... 09:33:59.201 CNTRLR [Node 025] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:33:59.253 SERIAL « [ACK] (0x06) 09:33:59.254 SERIAL « 0x0104011301e8 (6 bytes) 09:33:59.254 SERIAL » [ACK] (0x06) 09:33:59.257 DRIVER « [RES] [SendData] was sent: true 09:33:59.259 CNTRLR [Node 025] VersionCC: doing a partial interview... 09:33:59.260 CNTRLR [Node 025] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:33:59.260 CNTRLR [Node 025] trying to load device config 09:33:59.262 SERIAL « 0x01070013950000027c (9 bytes) 09:33:59.262 SERIAL » [ACK] (0x06) 09:33:59.263 DRIVER « [REQ] [SendData] callback id: 149 transmit status: OK 09:33:59.265 SERIAL « 0x01090004001a032503ff32 (11 bytes) 09:33:59.266 CNTRLR [Node 026] [~] [Binary Switch] currentValue: "unknown" => true [Endpoint 0] 09:33:59.266 SERIAL » [ACK] (0x06) 09:33:59.267 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: true 09:33:59.273 SERIAL » 0x010900130602984025968a (11 bytes) 09:33:59.273 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 150 └─[SecurityCCNonceGet] 09:33:59.274 CNTRLR [Node 026] The node is alive. 09:33:59.274 CNTRLR [Node 026] The node is ready to be used 09:33:59.275 CNTRLR « [Node 026] received Binary Switch state: current value: true 09:33:59.276 CNTRLR [Node 026] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 09:33:59.276 CNTRLR [Node 026] MultilevelSwitchCC: doing a partial interview... 09:33:59.276 CNTRLR » [Node 026] requesting current switch state... 09:33:59.291 CNTRLR [Node 025] device config loaded 09:33:59.291 CNTRLR » [Node 025] querying device endpoint information... 09:33:59.295 SERIAL « [ACK] (0x06) 09:33:59.296 SERIAL « 0x0104011301e8 (6 bytes) 09:33:59.297 SERIAL » [ACK] (0x06) 09:33:59.297 DRIVER « [RES] [SendData] was sent: true 09:34:00.578 SERIAL « 0x0107001396000082ff (9 bytes) 09:34:00.579 SERIAL » [ACK] (0x06) 09:34:00.579 DRIVER « [REQ] [SendData] callback id: 150 transmit status: OK 09:34:00.601 SERIAL « 0x0110000400060a98805a9057370c9d8da1e8 (18 bytes) 09:34:00.601 SERIAL » [ACK] (0x06) 09:34:00.602 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x5a9057370c9d8da1 09:34:00.606 SERIAL » 0x011d001306169881c6521803ccf548d76b1f885a0b53aa31cc5f44ea25973b (31 bytes) 09:34:00.607 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 151 └─[SecurityCCCommandEncapsulation] │ nonce id: 90 └─[MultiChannelCCEndPointGet] 09:34:00.609 SERIAL « [ACK] (0x06) 09:34:00.617 SERIAL « 0x0104011301e8 (6 bytes) 09:34:00.617 SERIAL » [ACK] (0x06) 09:34:00.617 DRIVER « [RES] [SendData] was sent: true 09:34:00.641 SERIAL « 0x01070013970000037f (9 bytes) 09:34:00.642 SERIAL » [ACK] (0x06) 09:34:00.642 DRIVER « [REQ] [SendData] callback id: 151 transmit status: OK 09:34:00.663 SERIAL « 0x0108000400060298402f (10 bytes) 09:34:00.664 SERIAL » [ACK] (0x06) 09:34:00.665 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:34:00.680 SERIAL » 0x01110013060a988091c552669eedc449240053 (19 bytes) 09:34:00.681 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x91c552669eedc449 09:34:00.683 SERIAL « [ACK] (0x06) 09:34:00.690 SERIAL « 0x0104011301e8 (6 bytes) 09:34:00.690 SERIAL » [ACK] (0x06) 09:34:00.691 DRIVER « [RES] [SendData] was sent: true 09:34:00.731 SERIAL « 0x011f000400061998814254cceafda28e63b65333ebd5a291248a108cea287d645 (33 bytes) 2 09:34:00.733 SERIAL » [ACK] (0x06) 09:34:00.735 CNTRLR [Node 006] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:34:00.735 CNTRLR [Node 006] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 09:34:00.736 CNTRLR [Node 006] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:34:00.736 CNTRLR [Node 006] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 09:34:00.737 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:34:00.745 SERIAL » 0x0109001319026007259824 (11 bytes) 09:34:00.746 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 152 └─[MultiChannelCCEndPointGet] 09:34:00.746 CNTRLR « [Node 006] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:34:00.747 CNTRLR » [Node 006] querying all endpoints... 09:34:00.751 SERIAL « [ACK] (0x06) 09:34:00.763 SERIAL « 0x0104011301e8 (6 bytes) 09:34:00.764 SERIAL » [ACK] (0x06) 09:34:00.764 DRIVER « [RES] [SendData] was sent: true 09:34:00.771 SERIAL « 0x010700139800000370 (9 bytes) 09:34:00.772 SERIAL » [ACK] (0x06) 09:34:00.773 DRIVER « [REQ] [SendData] callback id: 152 transmit status: OK 09:34:00.781 SERIAL « 0x010a000400190460084002c6 (12 bytes) 09:34:00.803 CNTRLR [Node 025] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:34:00.803 CNTRLR [Node 025] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 09:34:00.804 CNTRLR [Node 025] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:34:00.804 SERIAL » [ACK] (0x06) 09:34:00.806 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:34:00.811 SERIAL » 0x010900131202600725992e (11 bytes) 09:34:00.812 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 153 └─[MultiChannelCCEndPointGet] 09:34:00.813 CNTRLR « [Node 025] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:34:00.813 CNTRLR [Node 025] does not support EndPointFind, assuming that endpoints are sequenti al 09:34:00.813 CNTRLR » [Node 025] querying capabilities for endpoint #1... 09:34:00.817 SERIAL « [ACK] (0x06) 09:34:00.820 SERIAL « 0x0104011301e8 (6 bytes) 09:34:00.821 SERIAL » [ACK] (0x06) 09:34:00.821 DRIVER « [RES] [SendData] was sent: true 09:34:00.869 SERIAL « 0x010700139900000577 (9 bytes) 09:34:00.870 SERIAL » [ACK] (0x06) 09:34:00.872 DRIVER « [REQ] [SendData] callback id: 153 transmit status: OK 09:34:00.948 SERIAL « 0x010b000400120560080002008d (13 bytes) 09:34:00.949 CNTRLR [Node 018] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:34:00.949 CNTRLR [Node 018] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 09:34:00.949 CNTRLR [Node 018] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:34:00.950 CNTRLR [Node 018] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 09:34:00.950 SERIAL » [ACK] (0x06) 09:34:00.951 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:34:00.956 SERIAL » 0x010a00131903600901259a2b (12 bytes) 09:34:00.956 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 154 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:34:00.957 CNTRLR « [Node 018] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:34:00.957 CNTRLR » [Node 018] querying all endpoints... 09:34:00.963 SERIAL « [ACK] (0x06) 09:34:00.965 SERIAL « 0x0104011301e8 (6 bytes) 09:34:00.966 SERIAL » [ACK] (0x06) 09:34:00.966 DRIVER « [RES] [SendData] was sent: true 09:34:01.036 SERIAL « 0x010700139a00000879 (9 bytes) 09:34:01.037 SERIAL » [ACK] (0x06) 09:34:01.038 DRIVER « [REQ] [SendData] callback id: 154 transmit status: OK 09:34:01.047 SERIAL « 0x010c0004001906600a01100125b7 (14 bytes) 09:34:01.048 CNTRLR [Node 025] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 1] [internal] 7 09:34:01.049 SERIAL » [ACK] (0x06) 09:34:01.050 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:34:01.059 SERIAL » 0x010a00131303700523259b1e (12 bytes) 09:34:01.059 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 155 └─[ConfigurationCCGet] parameter #: 35 09:34:01.061 CNTRLR « [Node 025] received response for endpoint capabilities (#1): generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:34:01.061 CNTRLR [Node 025] all endpoints idendical, skipping capability query for endpoint #2. .. 09:34:01.062 CNTRLR [Node 025] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 2] [internal] 7 09:34:01.062 CNTRLR [Node 025] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:34:01.115 SERIAL « [ACK] (0x06) 09:34:01.121 SERIAL « 0x0104011301e8 (6 bytes) 09:34:01.121 SERIAL » [ACK] (0x06) 09:34:01.123 DRIVER « [RES] [SendData] was sent: true 09:34:01.126 SERIAL « 0x010700139b00000575 (9 bytes) 09:34:01.126 SERIAL » [ACK] (0x06) 09:34:01.128 CNTRLR [Node 025] WakeUpCC: doing a complete interview... 09:34:01.128 CNTRLR » [Node 025] retrieving wakeup interval from the device... 09:34:01.132 DRIVER « [REQ] [SendData] callback id: 155 transmit status: OK 09:34:01.168 SERIAL « 0x010b00040013057006230101b3 (13 bytes) 09:34:01.173 CNTRLR [Node 019] [~] [Configuration] 35: 1 => 1 09:34:01.174 SERIAL » [ACK] (0x06) 09:34:01.175 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 1 09:34:01.178 SERIAL » 0x0109001319028405259cc6 (11 bytes) 09:34:01.178 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 156 └─[WakeUpCCIntervalGet] 09:34:01.179 CNTRLR « [Node 019] parameter #35 has value: 1 09:34:01.179 CNTRLR » [Node 019] querying parameter #40 value... 09:34:01.182 SERIAL « [ACK] (0x06) 09:34:01.187 SERIAL « 0x0104011301e8 (6 bytes) 09:34:01.187 SERIAL » [ACK] (0x06) 09:34:01.188 DRIVER « [RES] [SendData] was sent: true 09:34:01.256 SERIAL « 0x010700139c00000770 (9 bytes) 09:34:01.256 SERIAL » [ACK] (0x06) 09:34:01.257 DRIVER « [REQ] [SendData] callback id: 156 transmit status: OK 09:34:02.860 CNTRLR [Node 025] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:34:03.366 SERIAL » 0x0109001319028405259cc6 (11 bytes) 09:34:03.367 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 156 └─[WakeUpCCIntervalGet] 09:34:03.369 SERIAL « [ACK] (0x06) 09:34:03.375 SERIAL « 0x0104011301e8 (6 bytes) 09:34:03.375 SERIAL » [ACK] (0x06) 09:34:03.376 DRIVER « [RES] [SendData] was sent: true 09:34:03.392 SERIAL « 0x010700139c00000275 (9 bytes) 09:34:03.393 SERIAL » [ACK] (0x06) 09:34:03.394 DRIVER « [REQ] [SendData] callback id: 156 transmit status: OK 09:34:04.999 CNTRLR [Node 025] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:34:05.502 SERIAL » 0x0109001319028405259cc6 (11 bytes) 09:34:05.503 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 156 └─[WakeUpCCIntervalGet] 09:34:05.504 SERIAL « [ACK] (0x06) 09:34:05.511 SERIAL « 0x0104011301e8 (6 bytes) 09:34:05.511 SERIAL » [ACK] (0x06) 09:34:05.512 DRIVER « [RES] [SendData] was sent: true 09:34:05.528 SERIAL « 0x010700139c00000275 (9 bytes) 09:34:05.529 SERIAL » [ACK] (0x06) 09:34:05.529 DRIVER « [REQ] [SendData] callback id: 156 transmit status: OK 09:34:06.278 SERIAL « 0x010c000400030631050422045abe (14 bytes) 09:34:06.280 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:34:06.281 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 276.3 => 111.4 [Endpoint 0] 09:34:06.282 SERIAL » [ACK] (0x06) 09:34:06.284 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 111.4 09:34:07.139 SERIAL » 0x010b00131604600bffff259d26 (13 bytes) 09:34:07.140 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 157 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:34:07.141 CNTRLR [Node 025] Interview attempt 2/5 failed, retrying in 10000 ms... 09:34:07.143 SERIAL « [ACK] (0x06) 09:34:07.149 SERIAL « 0x0104011301e8 (6 bytes) 09:34:07.149 SERIAL » [ACK] (0x06) 09:34:07.150 DRIVER « [RES] [SendData] was sent: true 09:34:07.277 SERIAL « 0x010c000400030631050422054aaf (14 bytes) 09:34:07.278 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:34:07.279 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 111.4 => 135.4 [Endpoint 0] 09:34:07.279 SERIAL » [ACK] (0x06) 09:34:07.281 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 135.4 09:34:08.666 SERIAL « 0x010700139d000098ee (9 bytes) 09:34:08.666 SERIAL » [ACK] (0x06) 09:34:08.666 DRIVER « [REQ] [SendData] callback id: 157 transmit status: OK 09:34:08.752 SERIAL « 0x010d0004001607600c00ffff010288 (15 bytes) 09:34:08.753 SERIAL » [ACK] (0x06) 09:34:08.754 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 09:34:08.759 SERIAL » 0x010b00131804600bffff259e2b (13 bytes) 09:34:08.759 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 158 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:34:08.760 CNTRLR « [Node 022] received endpoints: 1, 2 09:34:08.760 CNTRLR » [Node 022] querying capabilities for endpoint #1... 09:34:08.763 SERIAL « [ACK] (0x06) 09:34:08.767 SERIAL « 0x0104011301e8 (6 bytes) 09:34:08.767 SERIAL » [ACK] (0x06) 09:34:08.768 DRIVER « [RES] [SendData] was sent: true 09:34:08.850 SERIAL « 0x010700139e0000097c (9 bytes) 09:34:08.850 SERIAL » [ACK] (0x06) 09:34:08.851 DRIVER « [REQ] [SendData] callback id: 158 transmit status: OK 09:34:08.864 SERIAL « 0x010d0004001807600c00ffff010286 (15 bytes) 09:34:08.865 SERIAL » [ACK] (0x06) 09:34:08.865 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 09:34:08.868 SERIAL » 0x010900131a022602259f63 (11 bytes) 09:34:08.869 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 159 └─[MultilevelSwitchCCGet] 09:34:08.869 CNTRLR « [Node 024] received endpoints: 1, 2 09:34:08.869 CNTRLR » [Node 024] querying capabilities for endpoint #1... 09:34:08.872 SERIAL « [ACK] (0x06) 09:34:08.876 SERIAL « 0x0104011301e8 (6 bytes) 09:34:08.877 SERIAL » [ACK] (0x06) 09:34:08.877 DRIVER « [RES] [SendData] was sent: true 09:34:08.894 SERIAL « 0x010700139f00000276 (9 bytes) 09:34:08.894 SERIAL » [ACK] (0x06) 09:34:08.895 DRIVER « [REQ] [SendData] callback id: 159 transmit status: OK 09:34:08.904 SERIAL « 0x01090004001a03260363ad (11 bytes) 09:34:08.905 CNTRLR [Node 026] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 0] 09:34:08.905 SERIAL » [ACK] (0x06) 09:34:08.907 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 99 09:34:08.912 SERIAL » 0x010900130602984025a0bc (11 bytes) 09:34:08.912 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 160 └─[SecurityCCNonceGet] 09:34:08.913 CNTRLR [Node 026] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 09:34:08.951 SERIAL « [ACK] (0x06) 09:34:08.958 SERIAL « 0x0104011301e8 (6 bytes) 09:34:08.959 SERIAL » [ACK] (0x06) 09:34:08.961 DRIVER « [RES] [SendData] was sent: true 09:34:08.967 CNTRLR [Node 026] MultilevelSensorCC: doing a partial interview... 09:34:08.967 CNTRLR » [Node 026] querying current sensor reading... 09:34:09.156 CNTRLR [Node 023] Beginning interview - last completed stage: RestartFromCache 09:34:09.157 CNTRLR » [Node 023] pinging the node... 09:34:10.170 SERIAL « 0x01070013a000007e35 (9 bytes) 09:34:10.171 SERIAL » [ACK] (0x06) 09:34:10.172 DRIVER « [REQ] [SendData] callback id: 160 transmit status: OK 09:34:10.205 SERIAL « 0x0110000400060a9880d6c85b973494618965 (18 bytes) 09:34:10.207 SERIAL » [ACK] (0x06) 09:34:10.208 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xd6c85b9734946189 09:34:10.218 SERIAL » 0x011f0013061898813c95f5398460e2fdbc3e9a2f59d6a996f2c24c3ee00525a1c (33 bytes) e 09:34:10.219 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 161 └─[SecurityCCCommandEncapsulation] │ nonce id: 214 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:34:10.222 SERIAL « [ACK] (0x06) 09:34:10.229 SERIAL « 0x0104011301e8 (6 bytes) 09:34:10.230 SERIAL » [ACK] (0x06) 09:34:10.231 DRIVER « [RES] [SendData] was sent: true 09:34:10.254 SERIAL « 0x01070013a100000349 (9 bytes) 09:34:10.255 SERIAL » [ACK] (0x06) 09:34:10.256 DRIVER « [REQ] [SendData] callback id: 161 transmit status: OK 09:34:10.276 SERIAL « 0x0108000400060298402f (10 bytes) 09:34:10.276 SERIAL » [ACK] (0x06) 09:34:10.277 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:34:10.286 SERIAL » 0x01110013060a9880e8180243394e24cb2400e4 (19 bytes) 09:34:10.287 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xe8180243394e24cb 09:34:10.289 SERIAL « [ACK] (0x06) 09:34:10.295 SERIAL « 0x0104011301e8 (6 bytes) 09:34:10.296 SERIAL » [ACK] (0x06) 09:34:10.297 DRIVER « [RES] [SendData] was sent: true 09:34:10.337 SERIAL « 0x0121000400061b9881c21fc594870ab6fc08116a2778215b5be8fcb917880665a (35 bytes) 6caa5 09:34:10.338 SERIAL » [ACK] (0x06) 09:34:10.339 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 09:34:10.343 SERIAL » 0x0108001317010025a275 (10 bytes) 09:34:10.343 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 162 └─[NoOperationCC] 09:34:10.343 CNTRLR « [Node 006] received endpoints: 1, 2 09:34:10.344 CNTRLR » [Node 006] querying capabilities for endpoint #1... 09:34:10.349 SERIAL « [ACK] (0x06) 09:34:10.351 SERIAL « 0x0104011301e8 (6 bytes) 09:34:10.352 SERIAL » [ACK] (0x06) 09:34:10.353 DRIVER « [RES] [SendData] was sent: true 09:34:10.447 SERIAL « 0x01070013a200000a43 (9 bytes) 09:34:10.447 SERIAL » [ACK] (0x06) 09:34:10.448 DRIVER « [REQ] [SendData] callback id: 162 transmit status: OK 09:34:10.452 SERIAL » 0x010b00131204600bffff25a31c (13 bytes) 09:34:10.452 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 163 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:34:10.453 CNTRLR « [Node 023] ping successful 09:34:10.454 CNTRLR [Node 023] ManufacturerSpecificCC: doing a partial interview... 09:34:10.454 CNTRLR [Node 023] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:34:10.486 SERIAL « [ACK] (0x06) 09:34:10.489 SERIAL « 0x0104011301e8 (6 bytes) 09:34:10.489 SERIAL » [ACK] (0x06) 09:34:10.490 DRIVER « [RES] [SendData] was sent: true 09:34:10.493 CNTRLR [Node 023] VersionCC: doing a partial interview... 09:34:10.510 CNTRLR [Node 023] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:34:10.510 CNTRLR [Node 023] trying to load device config 09:34:10.512 SERIAL « 0x01070013a30000054d (9 bytes) 09:34:10.512 SERIAL » [ACK] (0x06) 09:34:10.513 DRIVER « [REQ] [SendData] callback id: 163 transmit status: OK 09:34:10.526 CNTRLR [Node 023] device config loaded 09:34:10.527 CNTRLR » [Node 023] querying device endpoint information... 09:34:10.588 SERIAL « 0x010d0004001207600c00ffff01028c (15 bytes) 09:34:10.589 SERIAL » [ACK] (0x06) 09:34:10.590 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 09:34:10.594 SERIAL » 0x010900131702600725a416 (11 bytes) 09:34:10.595 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 164 └─[MultiChannelCCEndPointGet] 09:34:10.595 CNTRLR « [Node 018] received endpoints: 1, 2 09:34:10.595 CNTRLR » [Node 018] querying capabilities for endpoint #1... 09:34:10.598 SERIAL « [ACK] (0x06) 09:34:10.603 SERIAL « 0x0104011301e8 (6 bytes) 09:34:10.603 SERIAL » [ACK] (0x06) 09:34:10.603 DRIVER « [RES] [SendData] was sent: true 09:34:10.754 SERIAL « 0x01070013a40000105f (9 bytes) 09:34:10.755 SERIAL » [ACK] (0x06) 09:34:10.755 DRIVER « [REQ] [SendData] callback id: 164 transmit status: OK 09:34:11.000 SERIAL « 0x010a000400170460084002c8 (12 bytes) 09:34:11.000 CNTRLR [Node 023] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:34:11.001 CNTRLR [Node 023] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 09:34:11.001 CNTRLR [Node 023] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:34:11.001 SERIAL » [ACK] (0x06) 09:34:11.002 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:34:11.005 SERIAL » 0x010a0013130370052825a52b (12 bytes) 09:34:11.005 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 165 └─[ConfigurationCCGet] parameter #: 40 09:34:11.006 CNTRLR « [Node 023] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:34:11.006 CNTRLR [Node 023] does not support EndPointFind, assuming that endpoints are sequenti al 09:34:11.006 CNTRLR » [Node 023] querying capabilities for endpoint #1... 09:34:11.010 SERIAL « [ACK] (0x06) 09:34:11.013 SERIAL « 0x0104011301e8 (6 bytes) 09:34:11.014 SERIAL » [ACK] (0x06) 09:34:11.015 DRIVER « [RES] [SendData] was sent: true 09:34:11.116 SERIAL « 0x01070013a500000b45 (9 bytes) 09:34:11.116 SERIAL » [ACK] (0x06) 09:34:11.117 DRIVER « [REQ] [SendData] callback id: 165 transmit status: OK 09:34:11.169 SERIAL « 0x010b0004001305700628010ab3 (13 bytes) 09:34:11.179 CNTRLR [Node 019] [~] [Configuration] 40: 10 => 10 09:34:11.181 SERIAL » [ACK] (0x06) 09:34:11.182 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 10 09:34:11.188 SERIAL » 0x010a0013170360090125a619 (12 bytes) 09:34:11.189 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 166 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:34:11.189 CNTRLR « [Node 019] parameter #40 has value: 10 09:34:11.190 CNTRLR » [Node 019] querying parameter #42 value... 09:34:11.203 SERIAL « [ACK] (0x06) 09:34:11.205 SERIAL « 0x0104011301e8 (6 bytes) 09:34:11.205 SERIAL » [ACK] (0x06) 09:34:11.208 DRIVER « [RES] [SendData] was sent: true 09:34:11.335 SERIAL « 0x01070013a600000e43 (9 bytes) 09:34:11.336 SERIAL » [ACK] (0x06) 09:34:11.336 DRIVER « [REQ] [SendData] callback id: 166 transmit status: OK 09:34:11.526 SERIAL « 0x010c0004001706600a01100125b9 (14 bytes) 09:34:11.527 CNTRLR [Node 023] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 1] [internal] 7 09:34:11.527 SERIAL » [ACK] (0x06) 09:34:11.528 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:34:11.531 SERIAL » 0x010a0013160360090125a719 (12 bytes) 09:34:11.531 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 167 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:34:11.532 CNTRLR « [Node 023] received response for endpoint capabilities (#1): generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:34:11.532 CNTRLR [Node 023] all endpoints idendical, skipping capability query for endpoint #2. .. 09:34:11.532 CNTRLR [Node 023] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 2] [internal] 7 09:34:11.533 CNTRLR [Node 023] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:34:11.562 SERIAL « [ACK] (0x06) 09:34:11.563 SERIAL « 0x0104011301e8 (6 bytes) 09:34:11.563 SERIAL » [ACK] (0x06) 09:34:11.566 DRIVER « [RES] [SendData] was sent: true 09:34:11.568 CNTRLR [Node 023] WakeUpCC: doing a complete interview... 09:34:11.569 CNTRLR » [Node 023] retrieving wakeup interval from the device... 09:34:12.990 SERIAL « 0x01070013a7000092de (9 bytes) 09:34:12.991 SERIAL » [ACK] (0x06) 09:34:12.991 DRIVER « [REQ] [SendData] callback id: 167 transmit status: OK 09:34:13.083 SERIAL « 0x011a0004001614600a0108065e8e404353989f596c71758081852296 (28 bytes) 09:34:13.084 CNTRLR [Node 022] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 1] [internal] 64,67,83,152,159,89,108,113,117,128,129,133,34 => 94,142,64,67,83,152,159,89,1 08,113,117,128,129,133,34 09:34:13.084 SERIAL » [ACK] (0x06) 09:34:13.085 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:34:13.088 SERIAL » 0x010900131702840525a8fc (11 bytes) 09:34:13.088 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 168 └─[WakeUpCCIntervalGet] 09:34:13.089 CNTRLR « [Node 022] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:34:13.089 CNTRLR » [Node 022] querying capabilities for endpoint #2... 09:34:13.092 SERIAL « [ACK] (0x06) 09:34:13.096 SERIAL « 0x0104011301e8 (6 bytes) 09:34:13.096 SERIAL » [ACK] (0x06) 09:34:13.097 DRIVER « [RES] [SendData] was sent: true 09:34:13.303 SERIAL « 0x01070013a800001556 (9 bytes) 09:34:13.304 SERIAL » [ACK] (0x06) 09:34:13.304 DRIVER « [REQ] [SendData] callback id: 168 transmit status: OK 09:34:14.907 CNTRLR [Node 023] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:34:15.412 SERIAL » 0x010900131702840525a8fc (11 bytes) 09:34:15.412 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 168 └─[WakeUpCCIntervalGet] 09:34:15.414 SERIAL « [ACK] (0x06) 09:34:15.420 SERIAL « 0x0104011301e8 (6 bytes) 09:34:15.420 SERIAL » [ACK] (0x06) 09:34:15.421 DRIVER « [RES] [SendData] was sent: true 09:34:15.522 SERIAL « 0x01070013a800000b48 (9 bytes) 09:34:15.522 SERIAL » [ACK] (0x06) 09:34:15.523 DRIVER « [REQ] [SendData] callback id: 168 transmit status: OK 09:34:17.126 CNTRLR [Node 023] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:34:17.141 CNTRLR [Node 025] Beginning interview - last completed stage: RestartFromCache 09:34:17.142 CNTRLR » [Node 025] pinging the node... 09:34:17.628 SERIAL » 0x010900131702840525a8fc (11 bytes) 09:34:17.628 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 168 └─[WakeUpCCIntervalGet] 09:34:17.630 SERIAL « [ACK] (0x06) 09:34:17.636 SERIAL « 0x0104011301e8 (6 bytes) 09:34:17.636 SERIAL » [ACK] (0x06) 09:34:17.637 DRIVER « [RES] [SendData] was sent: true 09:34:17.733 SERIAL « 0x01070013a800000a49 (9 bytes) 09:34:17.733 SERIAL » [ACK] (0x06) 09:34:17.734 DRIVER « [REQ] [SendData] callback id: 168 transmit status: OK 09:34:18.279 SERIAL « 0x010c0004000306310504220a6e84 (14 bytes) 09:34:18.281 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:34:18.282 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 135.4 => 267 [Endpoint 0] 09:34:18.283 SERIAL » [ACK] (0x06) 09:34:18.285 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 267 09:34:19.279 SERIAL « 0x010c00040003063105042204e400 (14 bytes) 09:34:19.280 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:34:19.281 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 267 => 125.2 [Endpoint 0] 09:34:19.281 SERIAL » [ACK] (0x06) 09:34:19.282 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 125.2 09:34:19.342 SERIAL » 0x0108001319010025a970 (10 bytes) 09:34:19.343 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 169 └─[NoOperationCC] 09:34:19.344 CNTRLR [Node 023] Interview attempt 3/5 failed, retrying in 15000 ms... 09:34:19.345 SERIAL « [ACK] (0x06) 09:34:19.352 SERIAL « 0x0104011301e8 (6 bytes) 09:34:19.352 SERIAL » [ACK] (0x06) 09:34:19.353 DRIVER « [RES] [SendData] was sent: true 09:34:19.369 SERIAL « 0x01070013a900000240 (9 bytes) 09:34:19.369 SERIAL » [ACK] (0x06) 09:34:19.370 DRIVER « [REQ] [SendData] callback id: 169 transmit status: OK 09:34:19.377 SERIAL » 0x010a0013180360090125aa1a (12 bytes) 09:34:19.377 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 170 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:34:19.378 CNTRLR « [Node 025] ping successful 09:34:19.379 CNTRLR [Node 025] ManufacturerSpecificCC: doing a partial interview... 09:34:19.380 CNTRLR [Node 025] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:34:19.429 SERIAL « [ACK] (0x06) 09:34:19.433 SERIAL « 0x0104011301e8 (6 bytes) 09:34:19.434 SERIAL » [ACK] (0x06) 09:34:19.435 DRIVER « [RES] [SendData] was sent: true 09:34:19.437 CNTRLR [Node 025] VersionCC: doing a partial interview... 09:34:19.437 CNTRLR [Node 025] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:34:19.437 CNTRLR [Node 025] trying to load device config 09:34:19.439 SERIAL « 0x01070013aa00000243 (9 bytes) 09:34:19.439 SERIAL » [ACK] (0x06) 09:34:19.440 DRIVER « [REQ] [SendData] callback id: 170 transmit status: OK 09:34:19.443 SERIAL « 0x0114000400180e600a0110015e862585598e32ef26d7 (22 bytes) 09:34:19.443 CNTRLR [Node 024] [~] [Multi Channel] commandClasses: 94,134, [Endpoint 1] [internal] 37,133,89,142,50 => 94,134,37,133,89,142,50 09:34:19.443 SERIAL » [ACK] (0x06) 09:34:19.456 CNTRLR [Node 025] device config loaded 09:34:19.456 CNTRLR » [Node 025] querying device endpoint information... 09:34:19.458 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Z-Wave Plus Info · Version · Binary Switch · Association · Association Group Information · Multi Channel Association · Meter 09:34:19.462 SERIAL » 0x010900131902600725ab17 (11 bytes) 09:34:19.462 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 171 └─[MultiChannelCCEndPointGet] 09:34:19.462 CNTRLR « [Node 024] received response for endpoint capabilities (#1): generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Z-Wave Plus Info · Version · Binary Switch · Association · Association Group Information · Multi Channel Association · Meter 09:34:19.463 CNTRLR [Node 024] all endpoints idendical, skipping capability query for endpoint #2. .. 09:34:19.463 CNTRLR [Node 024] [~] [Multi Channel] commandClasses: 94,134, [Endpoint 2] [internal] 37,133,89,142,50 => 94,134,37,133,89,142,50 09:34:19.463 CNTRLR [Node 024] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:34:19.465 CNTRLR [Node 024] ZWavePlusCC: doing a partial interview... [Endpoint 1] 09:34:19.465 CNTRLR [Node 024] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 09:34:19.465 CNTRLR [Node 024] BinarySwitchCC: doing a partial interview... [Endpoint 1] 09:34:19.465 CNTRLR » [Node 024] querying Binary Switch state... [Endpoint 1] 09:34:19.468 SERIAL « [ACK] (0x06) 09:34:19.470 SERIAL « 0x0104011301e8 (6 bytes) 09:34:19.470 SERIAL » [ACK] (0x06) 09:34:19.471 DRIVER « [RES] [SendData] was sent: true 09:34:19.487 SERIAL « 0x01070013ab00000242 (9 bytes) 09:34:19.488 SERIAL » [ACK] (0x06) 09:34:19.488 DRIVER « [REQ] [SendData] callback id: 171 transmit status: OK 09:34:19.497 SERIAL « 0x010a000400190460084002c6 (12 bytes) 09:34:19.498 CNTRLR [Node 025] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:34:19.498 CNTRLR [Node 025] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 09:34:19.499 CNTRLR [Node 025] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:34:19.499 SERIAL » [ACK] (0x06) 09:34:19.499 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:34:19.505 SERIAL » 0x010900131a02310425ac41 (11 bytes) 09:34:19.505 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 172 └─[MultilevelSensorCCGet] 09:34:19.506 CNTRLR « [Node 025] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:34:19.506 CNTRLR [Node 025] does not support EndPointFind, assuming that endpoints are sequenti al 09:34:19.506 CNTRLR » [Node 025] querying capabilities for endpoint #1... 09:34:19.509 SERIAL « [ACK] (0x06) 09:34:19.513 SERIAL « 0x0104011301e8 (6 bytes) 09:34:19.514 SERIAL » [ACK] (0x06) 09:34:19.514 DRIVER « [RES] [SendData] was sent: true 09:34:19.531 SERIAL « 0x01070013ac00000344 (9 bytes) 09:34:19.531 SERIAL » [ACK] (0x06) 09:34:19.531 DRIVER « [REQ] [SendData] callback id: 172 transmit status: OK 09:34:19.541 SERIAL « 0x010c0004001a06310504220000f9 (14 bytes) 09:34:19.542 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:34:19.542 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 09:34:19.543 SERIAL » [ACK] (0x06) 09:34:19.544 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 09:34:19.547 SERIAL » 0x010a0013190360090125ad1c (12 bytes) 09:34:19.547 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 173 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:34:19.548 CNTRLR « [Node 026] received current sensor reading: sensor type: Power value: 0 W 09:34:19.548 CNTRLR [Node 026] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 09:34:19.549 CNTRLR [Node 026] MeterCC: doing a partial interview... 09:34:19.549 CNTRLR » [Node 026] querying meter value (type = Electric, scale = kWh)... 09:34:19.552 SERIAL « [ACK] (0x06) 09:34:19.555 SERIAL « 0x0104011301e8 (6 bytes) 09:34:19.556 SERIAL » [ACK] (0x06) 09:34:19.556 DRIVER « [RES] [SendData] was sent: true 09:34:19.573 SERIAL « 0x01070013ad00000244 (9 bytes) 09:34:19.573 SERIAL » [ACK] (0x06) 09:34:19.576 DRIVER « [REQ] [SendData] callback id: 173 transmit status: OK 09:34:19.583 SERIAL « 0x010c0004001906600a01100125b7 (14 bytes) 09:34:19.584 CNTRLR [Node 025] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 1] [internal] 7 09:34:19.584 SERIAL » [ACK] (0x06) 09:34:19.585 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:34:19.590 SERIAL » 0x010900130602984025aeb2 (11 bytes) 09:34:19.590 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 174 └─[SecurityCCNonceGet] 09:34:19.591 CNTRLR « [Node 025] received response for endpoint capabilities (#1): generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:34:19.591 CNTRLR [Node 025] all endpoints idendical, skipping capability query for endpoint #2. .. 09:34:19.592 CNTRLR [Node 025] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 2] [internal] 7 09:34:19.592 CNTRLR [Node 025] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:34:19.623 SERIAL « [ACK] (0x06) 09:34:19.626 SERIAL « 0x0104011301e8 (6 bytes) 09:34:19.626 SERIAL » [ACK] (0x06) 09:34:19.627 DRIVER « [RES] [SendData] was sent: true 09:34:19.629 CNTRLR [Node 025] WakeUpCC: doing a complete interview... 09:34:19.630 CNTRLR » [Node 025] retrieving wakeup interval from the device... 09:34:20.909 SERIAL « 0x01070013ae000083c6 (9 bytes) 09:34:20.910 SERIAL » [ACK] (0x06) 09:34:20.911 DRIVER « [REQ] [SendData] callback id: 174 transmit status: OK 09:34:20.931 SERIAL « 0x0110000400060a9880f95e7a06d8aee1a516 (18 bytes) 09:34:20.932 SERIAL » [ACK] (0x06) 09:34:20.933 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xf95e7a06d8aee1a5 09:34:20.939 SERIAL » 0x011e001306179881493ce3e921f33cfdef6790f9f9a1ba3297aaf787f125af91 (32 bytes) 09:34:20.940 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 175 └─[SecurityCCCommandEncapsulation] │ nonce id: 249 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:34:20.943 SERIAL « [ACK] (0x06) 09:34:20.950 SERIAL « 0x0104011301e8 (6 bytes) 09:34:20.950 SERIAL » [ACK] (0x06) 09:34:20.951 DRIVER « [RES] [SendData] was sent: true 09:34:20.977 SERIAL « 0x01070013af00000347 (9 bytes) 09:34:20.978 SERIAL » [ACK] (0x06) 09:34:20.979 DRIVER « [REQ] [SendData] callback id: 175 transmit status: OK 09:34:20.997 SERIAL « 0x0108000400060298402f (10 bytes) 09:34:20.997 SERIAL » [ACK] (0x06) 09:34:20.998 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:34:21.006 SERIAL » 0x01110013060a98803d2eee1412f881bf2400f0 (19 bytes) 09:34:21.007 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x3d2eee1412f881bf 09:34:21.009 SERIAL « [ACK] (0x06) 09:34:21.015 SERIAL « 0x0104011301e8 (6 bytes) 09:34:21.016 SERIAL » [ACK] (0x06) 09:34:21.017 DRIVER « [RES] [SendData] was sent: true 09:34:21.072 SERIAL « 0x0123000400061d98819f5b27d186dac7afd827c3160b0ff7564b2f3d166897a38 (37 bytes) 69bbefe1d 09:34:21.073 SERIAL » [ACK] (0x06) 09:34:21.075 CNTRLR [Node 006] [~] [Multi Channel] commandClasses: 94,152, [Endpoint 1] [internal] 159,34 => 94,152,159,34 09:34:21.076 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 09:34:21.082 SERIAL » 0x010900131902840525b0ea (11 bytes) 09:34:21.082 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 176 └─[WakeUpCCIntervalGet] 09:34:21.083 CNTRLR « [Node 006] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 09:34:21.083 CNTRLR » [Node 006] querying capabilities for endpoint #2... 09:34:21.089 SERIAL « 0x0108000400060298402f (10 bytes) 09:34:21.089 SERIAL » [ACK] (0x06) 09:34:21.090 SERIAL « [CAN] (0x18) 09:34:21.091 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 09:34:21.093 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:34:21.192 SERIAL » 0x010900131902840525b0ea (11 bytes) 09:34:21.192 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 176 └─[WakeUpCCIntervalGet] 09:34:21.194 SERIAL « [ACK] (0x06) 09:34:21.200 SERIAL « 0x0104011301e8 (6 bytes) 09:34:21.201 SERIAL » [ACK] (0x06) 09:34:21.201 DRIVER « [RES] [SendData] was sent: true 09:34:21.218 SERIAL « 0x01070013b000000259 (9 bytes) 09:34:21.218 SERIAL » [ACK] (0x06) 09:34:21.219 DRIVER « [REQ] [SendData] callback id: 176 transmit status: OK 09:34:22.823 CNTRLR [Node 025] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:34:23.331 SERIAL » 0x010900131902840525b0ea (11 bytes) 09:34:23.333 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 176 └─[WakeUpCCIntervalGet] 09:34:23.337 SERIAL « [ACK] (0x06) 09:34:23.342 SERIAL « 0x0104011301e8 (6 bytes) 09:34:23.344 SERIAL » [ACK] (0x06) 09:34:23.346 DRIVER « [RES] [SendData] was sent: true 09:34:23.359 SERIAL « 0x01070013b000000259 (9 bytes) 09:34:23.360 SERIAL » [ACK] (0x06) 09:34:23.361 DRIVER « [REQ] [SendData] callback id: 176 transmit status: OK 09:34:24.738 SERIAL « 0x0112000400180c600d02003202213202b2000001 (20 bytes) 09:34:24.739 CNTRLR [Node 024] [~] [Meter] value[66049]: 97.8 => 69 [Endpoint 2] 09:34:24.740 CNTRLR [Node 024] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 2] 09:34:24.740 SERIAL » [ACK] (0x06) 09:34:24.742 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 69 time delta: 0 seconds 09:34:24.967 CNTRLR [Node 025] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:34:25.473 SERIAL » 0x010900131902840525b0ea (11 bytes) 09:34:25.474 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 176 └─[WakeUpCCIntervalGet] 09:34:25.476 SERIAL « [ACK] (0x06) 09:34:25.482 SERIAL « 0x0104011301e8 (6 bytes) 09:34:25.483 SERIAL » [ACK] (0x06) 09:34:25.484 DRIVER « [RES] [SendData] was sent: true 09:34:25.500 SERIAL « 0x01070013b000000358 (9 bytes) 09:34:25.500 SERIAL » [ACK] (0x06) 09:34:25.502 DRIVER « [REQ] [SendData] callback id: 176 transmit status: OK 09:34:27.112 SERIAL » 0x01110013060a98808165e3005a6686922400e2 (19 bytes) 09:34:27.113 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x8165e3005a668692 09:34:27.114 CNTRLR [Node 025] Interview attempt 3/5 failed, retrying in 15000 ms... 09:34:27.116 SERIAL « [ACK] (0x06) 09:34:27.122 SERIAL « 0x0104011301e8 (6 bytes) 09:34:27.123 SERIAL » [ACK] (0x06) 09:34:27.124 DRIVER « [RES] [SendData] was sent: true 09:34:27.138 SERIAL » 0x010a0013120360090125b10b (12 bytes) 09:34:27.139 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 177 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:34:27.142 SERIAL « [ACK] (0x06) 09:34:27.147 SERIAL « 0x0104011301e8 (6 bytes) 09:34:27.148 SERIAL » [ACK] (0x06) 09:34:27.149 DRIVER « [RES] [SendData] was sent: true 09:34:27.197 SERIAL « 0x01070013b10000055f (9 bytes) 09:34:27.198 SERIAL » [ACK] (0x06) 09:34:27.198 DRIVER « [REQ] [SendData] callback id: 177 transmit status: OK 09:34:27.285 SERIAL « 0x011a0004001214600a0108065e8e404353989f596c71758081852292 (28 bytes) 09:34:27.287 CNTRLR [Node 018] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 1] [internal] 64,67,83,152,159,89,108,113,117,128,129,133,34 => 94,142,64,67,83,152,159,89,1 08,113,117,128,129,133,34 09:34:27.287 SERIAL » [ACK] (0x06) 09:34:27.288 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:34:27.294 SERIAL » 0x010a0013130370052a25b23e (12 bytes) 09:34:27.295 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 178 └─[ConfigurationCCGet] parameter #: 42 09:34:27.296 CNTRLR « [Node 018] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:34:27.296 CNTRLR » [Node 018] querying capabilities for endpoint #2... 09:34:27.301 SERIAL « [ACK] (0x06) 09:34:27.304 SERIAL « 0x0104011301e8 (6 bytes) 09:34:27.304 SERIAL » [ACK] (0x06) 09:34:27.305 DRIVER « [RES] [SendData] was sent: true 09:34:27.396 SERIAL « 0x01070013b200000a53 (9 bytes) 09:34:27.397 SERIAL » [ACK] (0x06) 09:34:27.398 DRIVER « [REQ] [SendData] callback id: 178 transmit status: OK 09:34:27.449 SERIAL « 0x010c000400130670062a020e10a2 (14 bytes) 09:34:27.459 CNTRLR [Node 019] [~] [Configuration] 42: 3600 => 3600 09:34:27.461 SERIAL » [ACK] (0x06) 09:34:27.462 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 3600 09:34:27.468 SERIAL » 0x010a0013160360090225b30e (12 bytes) 09:34:27.469 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 179 └─[MultiChannelCCCapabilityGet] endpoint: 2 09:34:27.469 CNTRLR « [Node 019] parameter #42 has value: 3600 09:34:27.469 CNTRLR » [Node 019] querying parameter #43 value... 09:34:27.475 SERIAL « [ACK] (0x06) 09:34:27.478 SERIAL « 0x0104011301e8 (6 bytes) 09:34:27.478 SERIAL » [ACK] (0x06) 09:34:27.482 DRIVER « [RES] [SendData] was sent: true 09:34:28.943 SERIAL « 0x01070013b3000093cb (9 bytes) 09:34:28.943 SERIAL » [ACK] (0x06) 09:34:28.944 DRIVER « [REQ] [SendData] callback id: 179 transmit status: OK 09:34:29.031 SERIAL « 0x01160004001610600a0221015e8e31989f596c7180852226 (24 bytes) 09:34:29.032 CNTRLR [Node 022] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 2] [internal] 49,152,159,89,108,113,128,133,34 => 94,142,49,152,159,89,108,113,128,133,34 09:34:29.032 SERIAL » [ACK] (0x06) 09:34:29.033 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:34:29.038 SERIAL » 0x010d00131806600d0001250225b425 (15 bytes) 09:34:29.039 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 180 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 09:34:29.039 CNTRLR « [Node 022] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:34:29.040 CNTRLR [Node 022] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:34:29.069 SERIAL « [ACK] (0x06) 09:34:29.074 SERIAL « 0x0104011301e8 (6 bytes) 09:34:29.074 SERIAL » [ACK] (0x06) 09:34:29.075 DRIVER « [RES] [SendData] was sent: true 09:34:29.077 CNTRLR [Node 022] BatteryCC: doing a partial interview... 09:34:29.077 CNTRLR » [Node 022] querying battery status... 09:34:29.122 SERIAL « 0x01070013b400000857 (9 bytes) 09:34:29.122 SERIAL » [ACK] (0x06) 09:34:29.123 DRIVER « [REQ] [SendData] callback id: 180 transmit status: OK 09:34:29.135 SERIAL « 0x010d0004001807600d0100250300a3 (15 bytes) 09:34:29.136 CNTRLR [Node 024] [~] [Binary Switch] currentValue: false => false [Endpoint 1] 09:34:29.136 SERIAL » [ACK] (0x06) 09:34:29.137 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: false 09:34:29.141 SERIAL » 0x010a00131a0332010025b55c (12 bytes) 09:34:29.141 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 181 └─[MeterCCGet] duration: kWh 09:34:29.141 CNTRLR « [Node 024] received Binary Switch state: [Endpoint 1] current value: false 09:34:29.142 CNTRLR [Node 024] [~] [Binary Switch] interviewComplete: true [Endpoint 1] [internal] => true 09:34:29.142 CNTRLR [Node 024] MeterCC: doing a partial interview... [Endpoint 1] 09:34:29.143 CNTRLR » [Node 024] querying default meter value... [Endpoint 1] 09:34:29.146 SERIAL « [ACK] (0x06) 09:34:29.150 SERIAL « 0x0104011301e8 (6 bytes) 09:34:29.150 SERIAL » [ACK] (0x06) 09:34:29.152 DRIVER « [RES] [SendData] was sent: true 09:34:29.167 SERIAL « 0x01070013b50000025c (9 bytes) 09:34:29.167 SERIAL » [ACK] (0x06) 09:34:29.168 DRIVER « [REQ] [SendData] callback id: 181 transmit status: OK 09:34:29.178 SERIAL « 0x01100004001a0a32022144000001d500007a (18 bytes) 09:34:29.180 CNTRLR [Node 026] [~] [Meter] value[65537]: 4.69 => 4.69 [Endpoint 0] 09:34:29.180 CNTRLR [Node 026] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 09:34:29.181 SERIAL » [ACK] (0x06) 09:34:29.182 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 4.69 time delta: 0 seconds 09:34:29.189 SERIAL » 0x010900130602984025b6aa (11 bytes) 09:34:29.189 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 182 └─[SecurityCCNonceGet] 09:34:29.190 CNTRLR » [Node 026] querying meter value (type = Electric, scale = W)... 09:34:29.193 SERIAL « [ACK] (0x06) 09:34:29.197 SERIAL « 0x0104011301e8 (6 bytes) 09:34:29.198 SERIAL » [ACK] (0x06) 09:34:29.200 DRIVER « [RES] [SendData] was sent: true 09:34:30.462 SERIAL « 0x01070013b600007f22 (9 bytes) 09:34:30.463 SERIAL » [ACK] (0x06) 09:34:30.464 DRIVER « [REQ] [SendData] callback id: 182 transmit status: OK 09:34:30.485 SERIAL « 0x0110000400060a98802c115e80b5c971e2f3 (18 bytes) 09:34:30.486 SERIAL » [ACK] (0x06) 09:34:30.487 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x2c115e80b5c971e2 09:34:30.494 SERIAL » 0x011e001306179881dab1b827575137e2cca820de2cfeed37fa8df4683a25b70c (32 bytes) 09:34:30.495 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 183 └─[SecurityCCCommandEncapsulation] │ nonce id: 44 └─[MultiChannelCCCapabilityGet] endpoint: 2 09:34:30.498 SERIAL « [ACK] (0x06) 09:34:30.505 SERIAL « 0x0104011301e8 (6 bytes) 09:34:30.506 SERIAL » [ACK] (0x06) 09:34:30.507 DRIVER « [RES] [SendData] was sent: true 09:34:30.530 SERIAL « 0x01070013b700000458 (9 bytes) 09:34:30.530 SERIAL » [ACK] (0x06) 09:34:30.531 DRIVER « [REQ] [SendData] callback id: 183 transmit status: OK 09:34:30.552 SERIAL « 0x0108000400060298402f (10 bytes) 09:34:30.553 SERIAL » [ACK] (0x06) 09:34:30.554 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:34:30.567 SERIAL » 0x01110013060a988049a6ce6ebf2ae17b24008d (19 bytes) 09:34:30.567 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x49a6ce6ebf2ae17b 09:34:30.570 SERIAL « [ACK] (0x06) 09:34:30.576 SERIAL « 0x0104011301e8 (6 bytes) 09:34:30.577 SERIAL » [ACK] (0x06) 09:34:30.577 DRIVER « [RES] [SendData] was sent: true 09:34:30.619 SERIAL « 0x0123000400061d9881ac432a567c2b961df604410a2ccff61b5be949e541a77d2 (37 bytes) db85cbcd2 09:34:30.620 SERIAL » [ACK] (0x06) 09:34:30.622 CNTRLR [Node 006] [~] [Multi Channel] commandClasses: 94,152, [Endpoint 2] [internal] 159,34 => 94,152,159,34 09:34:30.622 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 09:34:30.627 SERIAL » 0x010a0013120360090225b801 (12 bytes) 09:34:30.627 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 184 └─[MultiChannelCCCapabilityGet] endpoint: 2 09:34:30.628 CNTRLR « [Node 006] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 09:34:30.628 CNTRLR [Node 006] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:34:30.670 SERIAL « [ACK] (0x06) 09:34:30.674 SERIAL « 0x0104011301e8 (6 bytes) 09:34:30.675 SERIAL » [ACK] (0x06) 09:34:30.676 DRIVER « [RES] [SendData] was sent: true 09:34:30.678 CNTRLR [Node 006] BatteryCC: doing a partial interview... 09:34:30.679 CNTRLR » [Node 006] querying battery status... 09:34:30.685 SERIAL « 0x01070013b800000556 (9 bytes) 09:34:30.685 SERIAL » [ACK] (0x06) 09:34:30.686 DRIVER « [REQ] [SendData] callback id: 184 transmit status: OK 09:34:30.773 SERIAL « 0x01160004001210600a0221015e8e31989f596c7180852222 (24 bytes) 09:34:30.773 CNTRLR [Node 018] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 2] [internal] 49,152,159,89,108,113,128,133,34 => 94,142,49,152,159,89,108,113,128,133,34 09:34:30.774 SERIAL » [ACK] (0x06) 09:34:30.774 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:34:30.777 SERIAL » 0x010a0013130370052b25b934 (12 bytes) 09:34:30.778 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 185 └─[ConfigurationCCGet] parameter #: 43 09:34:30.778 CNTRLR « [Node 018] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:34:30.779 CNTRLR [Node 018] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:34:30.779 CNTRLR [Node 018] BatteryCC: doing a partial interview... 09:34:30.779 CNTRLR » [Node 018] querying battery status... 09:34:30.783 SERIAL « [ACK] (0x06) 09:34:30.786 SERIAL « 0x0104011301e8 (6 bytes) 09:34:30.786 SERIAL » [ACK] (0x06) 09:34:30.787 DRIVER « [RES] [SendData] was sent: true 09:34:30.886 SERIAL « 0x01070013b900000a58 (9 bytes) 09:34:30.886 SERIAL » [ACK] (0x06) 09:34:30.887 DRIVER « [REQ] [SendData] callback id: 185 transmit status: OK 09:34:30.939 SERIAL « 0x010b000400130570062b010ab0 (13 bytes) 09:34:30.946 CNTRLR [Node 019] [~] [Configuration] 43: 10 => 10 09:34:30.946 SERIAL » [ACK] (0x06) 09:34:30.947 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 10 09:34:30.950 SERIAL » 0x010900131602800225baec (11 bytes) 09:34:30.951 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 186 └─[BatteryCCGet] 09:34:30.951 CNTRLR « [Node 019] parameter #43 has value: 10 09:34:30.951 CNTRLR » [Node 019] querying parameter #44 value... 09:34:30.954 SERIAL « [ACK] (0x06) 09:34:30.960 SERIAL « 0x0104011301e8 (6 bytes) 09:34:30.960 SERIAL » [ACK] (0x06) 09:34:30.961 DRIVER « [RES] [SendData] was sent: true 09:34:32.459 SERIAL « 0x01070013ba000096c7 (9 bytes) 09:34:32.460 SERIAL » [ACK] (0x06) 09:34:32.461 DRIVER « [REQ] [SendData] callback id: 186 transmit status: OK 09:34:32.574 SERIAL « 0x0109000400160380036307 (11 bytes) 09:34:32.575 CNTRLR [Node 022] [~] [Battery] level: 99 => 99 [Endpoint 0] 09:34:32.576 CNTRLR [Node 022] [~] [Battery] isLow: false => false [Endpoint 0] 09:34:32.576 SERIAL » [ACK] (0x06) 09:34:32.578 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 99 is low: false 09:34:32.583 SERIAL » 0x010d00131806600d0001320125bb3e (15 bytes) 09:34:32.583 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 187 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[MeterCCGet] 09:34:32.584 CNTRLR « [Node 022] received response for battery information: level: 99 09:34:32.584 CNTRLR [Node 022] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:34:32.628 SERIAL « [ACK] (0x06) 09:34:32.632 SERIAL « 0x0104011301e8 (6 bytes) 09:34:32.632 SERIAL » [ACK] (0x06) 09:34:32.633 DRIVER « [RES] [SendData] was sent: true 09:34:32.638 CNTRLR [Node 022] ZWavePlusCC: doing a partial interview... [Endpoint 1] 09:34:32.638 CNTRLR [Node 022] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 09:34:32.639 CNTRLR [Node 022] ThermostatModeCC: doing a partial interview... [Endpoint 1] 09:34:32.640 CNTRLR » [Node 022] querying current thermostat mode... [Endpoint 1] 09:34:32.673 SERIAL « 0x01070013bb00000959 (9 bytes) 09:34:32.673 SERIAL » [ACK] (0x06) 09:34:32.674 DRIVER « [REQ] [SendData] callback id: 187 transmit status: OK 09:34:32.686 SERIAL « 0x0112000400180c600d010032020144000001bf5a (20 bytes) 09:34:32.688 CNTRLR [Node 024] [~] [Meter] value[65536]: 4.47 => 4.47 [Endpoint 1] 09:34:32.689 CNTRLR [Node 024] [~] [Meter] deltaTime[65536]: 0 => 0 [Endpoint 1] 09:34:32.689 SERIAL » [ACK] (0x06) 09:34:32.695 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[MeterCCReport] type: Electric scale: kWh rate type: Unspecified value: 4.47 time delta: 0 seconds 09:34:32.711 SERIAL » 0x010a00131a0332011025bc45 (12 bytes) 09:34:32.712 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 188 └─[MeterCCGet] duration: W 09:34:32.713 CNTRLR [Node 024] [~] [Meter] interviewComplete: true => true [Endpoint 1] [internal] 09:34:32.726 CNTRLR [Node 024] ZWavePlusCC: doing a partial interview... [Endpoint 2] 09:34:32.726 CNTRLR [Node 024] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 09:34:32.727 CNTRLR [Node 024] BinarySwitchCC: doing a partial interview... [Endpoint 2] 09:34:32.727 CNTRLR » [Node 024] querying Binary Switch state... [Endpoint 2] 09:34:32.733 SERIAL « [ACK] (0x06) 09:34:32.734 SERIAL « 0x0104011301e8 (6 bytes) 09:34:32.734 SERIAL » [ACK] (0x06) 09:34:32.735 DRIVER « [RES] [SendData] was sent: true 09:34:32.738 SERIAL « 0x01070013bc00000255 (9 bytes) 09:34:32.739 SERIAL » [ACK] (0x06) 09:34:32.740 DRIVER « [REQ] [SendData] callback id: 188 transmit status: OK 09:34:32.750 SERIAL « 0x010e0004001a083202213200000000c4 (16 bytes) 09:34:32.751 CNTRLR [Node 026] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 09:34:32.752 CNTRLR [Node 026] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 09:34:32.753 SERIAL » [ACK] (0x06) 09:34:32.754 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 09:34:32.761 SERIAL » 0x010900130602984025bda1 (11 bytes) 09:34:32.761 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 189 └─[SecurityCCNonceGet] 09:34:32.762 CNTRLR [Node 026] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 09:34:32.762 CNTRLR [Node 026] ConfigurationCC: Loading configuration parameters from device confi g 09:34:32.769 CNTRLR [Node 026] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:34:32.771 CNTRLR [Node 026] [Configuration] 3: metadata updated 09:34:32.772 CNTRLR [Node 026] [Configuration] 10: metadata updated 09:34:32.773 CNTRLR [Node 026] [Configuration] 12: metadata updated 09:34:32.774 CNTRLR [Node 026] [Configuration] 13: metadata updated 09:34:32.775 CNTRLR [Node 026] [Configuration] 14: metadata updated 09:34:32.776 CNTRLR [Node 026] [Configuration] 17: metadata updated 09:34:32.777 CNTRLR [Node 026] [Configuration] 18: metadata updated 09:34:32.778 CNTRLR [Node 026] [Configuration] 22: metadata updated 09:34:32.779 CNTRLR [Node 026] [Configuration] 29: metadata updated 09:34:32.780 CNTRLR [Node 026] [Configuration] 30: metadata updated 09:34:32.781 CNTRLR [Node 026] [Configuration] 31: metadata updated 09:34:32.782 CNTRLR [Node 026] [Configuration] 32: metadata updated 09:34:32.783 CNTRLR [Node 026] [Configuration] 33: metadata updated 09:34:32.784 CNTRLR [Node 026] [Configuration] 35: metadata updated 09:34:32.785 CNTRLR [Node 026] [Configuration] 40: metadata updated 09:34:32.786 CNTRLR [Node 026] [Configuration] 42: metadata updated 09:34:32.787 CNTRLR [Node 026] [Configuration] 43: metadata updated 09:34:32.788 CNTRLR [Node 026] [Configuration] 44: metadata updated 09:34:32.789 CNTRLR [Node 026] [Configuration] 50: metadata updated 09:34:32.790 CNTRLR [Node 026] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:34:32.790 CNTRLR » [Node 026] querying parameter #3 value... 09:34:32.826 SERIAL « [ACK] (0x06) 09:34:32.827 SERIAL « 0x0104011301e8 (6 bytes) 09:34:32.828 SERIAL » [ACK] (0x06) 09:34:32.829 DRIVER « [RES] [SendData] was sent: true 09:34:34.022 SERIAL « 0x01070013bd00007e28 (9 bytes) 09:34:34.022 SERIAL » [ACK] (0x06) 09:34:34.023 DRIVER « [REQ] [SendData] callback id: 189 transmit status: OK 09:34:34.043 SERIAL « 0x0110000400060a9880e9ac9c789888343b41 (18 bytes) 09:34:34.044 SERIAL » [ACK] (0x06) 09:34:34.045 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xe9ac9c789888343b 09:34:34.053 SERIAL » 0x011d0013061698818029f6fdc3b8507ed9c556e9380135798300c13f25be3f (31 bytes) 09:34:34.054 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 190 └─[SecurityCCCommandEncapsulation] │ nonce id: 233 └─[BatteryCCGet] 09:34:34.057 SERIAL « [ACK] (0x06) 09:34:34.064 SERIAL « 0x0104011301e8 (6 bytes) 09:34:34.064 SERIAL » [ACK] (0x06) 09:34:34.065 DRIVER « [RES] [SendData] was sent: true 09:34:34.088 SERIAL « 0x01070013be00000356 (9 bytes) 09:34:34.089 SERIAL » [ACK] (0x06) 09:34:34.090 DRIVER « [REQ] [SendData] callback id: 190 transmit status: OK 09:34:34.206 SERIAL « 0x0108000400060298402f (10 bytes) 09:34:34.207 SERIAL » [ACK] (0x06) 09:34:34.208 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:34:34.216 SERIAL » 0x01110013060a988009b2a843a0a9aa3124000f (19 bytes) 09:34:34.217 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x09b2a843a0a9aa31 09:34:34.219 SERIAL « [ACK] (0x06) 09:34:34.225 SERIAL « 0x0104011301e8 (6 bytes) 09:34:34.226 SERIAL » [ACK] (0x06) 09:34:34.227 DRIVER « [RES] [SendData] was sent: true 09:34:34.266 SERIAL « 0x011d00040006179881ca80da43c92fb1c44dcd1a8d099b99539a9e97b9e922 (31 bytes) 09:34:34.268 SERIAL » [ACK] (0x06) 09:34:34.270 CNTRLR [Node 006] [~] [Battery] level: 89 => 89 [Endpoint 0] 09:34:34.271 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 0] 09:34:34.273 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[BatteryCCReport] level: 89 is low: false 09:34:34.278 SERIAL » 0x010900131202800225bfed (11 bytes) 09:34:34.279 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 191 └─[BatteryCCGet] 09:34:34.280 CNTRLR « [Node 006] received response for battery information: level: 89 09:34:34.281 CNTRLR [Node 006] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:34:34.286 CNTRLR [Node 006] ZWavePlusCC: doing a partial interview... [Endpoint 1] 09:34:34.287 CNTRLR [Node 006] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 09:34:34.287 CNTRLR [Node 006] ThermostatModeCC: doing a partial interview... [Endpoint 1] 09:34:34.287 CNTRLR » [Node 006] querying current thermostat mode... [Endpoint 1] 09:34:34.303 SERIAL « [ACK] (0x06) 09:34:34.305 SERIAL « 0x0104011301e8 (6 bytes) 09:34:34.305 SERIAL » [ACK] (0x06) 09:34:34.307 DRIVER « [RES] [SendData] was sent: true 09:34:34.335 SERIAL « 0x01070013bf00000551 (9 bytes) 09:34:34.335 SERIAL » [ACK] (0x06) 09:34:34.336 DRIVER « [REQ] [SendData] callback id: 191 transmit status: OK 09:34:34.345 CNTRLR [Node 023] Beginning interview - last completed stage: RestartFromCache 09:34:34.346 CNTRLR » [Node 023] pinging the node... 09:34:34.738 SERIAL « 0x0112000400180c600d020032022132045c0000e9 (20 bytes) 09:34:34.740 CNTRLR [Node 024] [~] [Meter] value[66049]: 69 => 111.6 [Endpoint 2] 09:34:34.742 CNTRLR [Node 024] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 2] 09:34:34.743 SERIAL » [ACK] (0x06) 09:34:34.745 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 111.6 time delta: 0 seconds 09:34:35.940 CNTRLR [Node 018] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:34:36.324 SERIAL « 0x01080004001b02840769 (10 bytes) 09:34:36.325 SERIAL » [ACK] (0x06) 09:34:36.326 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:34:36.334 CNTRLR « [Node 027] received wakeup notification 09:34:36.336 CNTRLR [Node 027] The node is awake. 09:34:36.337 CNTRLR [Node 027] The node is ready to be used 09:34:36.675 SERIAL » 0x010900131202800225bfed (11 bytes) 09:34:36.675 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 191 └─[BatteryCCGet] 09:34:36.677 SERIAL « [ACK] (0x06) 09:34:36.683 SERIAL « 0x0104011301e8 (6 bytes) 09:34:36.683 SERIAL » [ACK] (0x06) 09:34:36.684 DRIVER « [RES] [SendData] was sent: true 09:34:36.735 SERIAL « 0x01070013bf00000652 (9 bytes) 09:34:36.736 SERIAL » [ACK] (0x06) 09:34:36.736 DRIVER « [REQ] [SendData] callback id: 191 transmit status: OK 09:34:38.282 SERIAL « 0x010c000400030631050422054bae (14 bytes) 09:34:38.283 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:34:38.287 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 125.2 => 135.5 [Endpoint 0] 09:34:38.287 SERIAL » [ACK] (0x06) 09:34:38.289 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 135.5 09:34:38.341 CNTRLR [Node 018] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:34:38.844 SERIAL » 0x010900131202800225bfed (11 bytes) 09:34:38.845 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 191 └─[BatteryCCGet] 09:34:38.846 SERIAL « [ACK] (0x06) 09:34:38.853 SERIAL « 0x0104011301e8 (6 bytes) 09:34:38.853 SERIAL » [ACK] (0x06) 09:34:38.854 DRIVER « [RES] [SendData] was sent: true 09:34:38.900 SERIAL « 0x01070013bf00000652 (9 bytes) 09:34:38.901 SERIAL » [ACK] (0x06) 09:34:38.902 DRIVER « [REQ] [SendData] callback id: 191 transmit status: OK 09:34:40.511 SERIAL » 0x0108001317010025c017 (10 bytes) 09:34:40.512 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 192 └─[NoOperationCC] 09:34:40.513 CNTRLR [Node 018] Battery status query timed out - skipping because it is not critica l... 09:34:40.514 CNTRLR [Node 018] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:34:40.575 SERIAL « [ACK] (0x06) 09:34:40.582 SERIAL « 0x0104011301e8 (6 bytes) 09:34:40.583 SERIAL » [ACK] (0x06) 09:34:40.585 DRIVER « [RES] [SendData] was sent: true 09:34:40.591 CNTRLR [Node 018] ZWavePlusCC: doing a partial interview... [Endpoint 1] 09:34:40.591 CNTRLR [Node 018] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 09:34:40.592 CNTRLR [Node 018] ThermostatModeCC: doing a partial interview... [Endpoint 1] 09:34:40.592 CNTRLR » [Node 018] querying current thermostat mode... [Endpoint 1] 09:34:40.615 SERIAL « 0x01070013c000000a21 (9 bytes) 09:34:40.616 SERIAL » [ACK] (0x06) 09:34:40.617 DRIVER « [REQ] [SendData] callback id: 192 transmit status: OK 09:34:40.624 SERIAL » 0x010a0013130370052c25c14b (12 bytes) 09:34:40.624 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 193 └─[ConfigurationCCGet] parameter #: 44 09:34:40.625 CNTRLR « [Node 023] ping successful 09:34:40.626 CNTRLR [Node 023] ManufacturerSpecificCC: doing a partial interview... 09:34:40.626 CNTRLR [Node 023] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:34:40.627 CNTRLR [Node 023] VersionCC: doing a partial interview... 09:34:40.627 CNTRLR [Node 023] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:34:40.627 CNTRLR [Node 023] trying to load device config 09:34:40.630 SERIAL « [ACK] (0x06) 09:34:40.641 CNTRLR [Node 023] device config loaded 09:34:40.642 CNTRLR » [Node 023] querying device endpoint information... 09:34:40.644 SERIAL « 0x0104011301e8 (6 bytes) 09:34:40.645 SERIAL » [ACK] (0x06) 09:34:40.645 DRIVER « [RES] [SendData] was sent: true 09:34:40.679 SERIAL « 0x01070013c10000052f (9 bytes) 09:34:40.679 SERIAL » [ACK] (0x06) 09:34:40.679 DRIVER « [REQ] [SendData] callback id: 193 transmit status: OK 09:34:40.730 SERIAL « 0x010b000400130570062c0100bd (13 bytes) 09:34:40.735 CNTRLR [Node 019] [~] [Configuration] 44: 0 => 0 09:34:40.736 SERIAL » [ACK] (0x06) 09:34:40.737 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 44 value size: 1 value: 0 09:34:40.740 SERIAL » 0x010900131702600725c270 (11 bytes) 09:34:40.741 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 194 └─[MultiChannelCCEndPointGet] 09:34:40.741 CNTRLR « [Node 019] parameter #44 has value: 0 09:34:40.741 CNTRLR » [Node 019] querying parameter #50 value... 09:34:40.770 SERIAL « [ACK] (0x06) 09:34:40.776 SERIAL « 0x0104011301e8 (6 bytes) 09:34:40.776 SERIAL » [ACK] (0x06) 09:34:40.777 DRIVER « [RES] [SendData] was sent: true 09:34:40.904 SERIAL « 0x01070013c200001039 (9 bytes) 09:34:40.904 SERIAL » [ACK] (0x06) 09:34:40.904 DRIVER « [REQ] [SendData] callback id: 194 transmit status: OK 09:34:41.083 SERIAL « 0x010a000400170460084002c8 (12 bytes) 09:34:41.084 CNTRLR [Node 023] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:34:41.084 CNTRLR [Node 023] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 09:34:41.085 CNTRLR [Node 023] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:34:41.085 SERIAL » [ACK] (0x06) 09:34:41.085 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:34:41.092 SERIAL » 0x010d00131606600d0001400225c339 (15 bytes) 09:34:41.093 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 195 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:34:41.093 CNTRLR « [Node 023] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:34:41.094 CNTRLR [Node 023] does not support EndPointFind, assuming that endpoints are sequenti al 09:34:41.094 CNTRLR » [Node 023] querying capabilities for endpoint #1... 09:34:41.097 SERIAL « [ACK] (0x06) 09:34:41.101 SERIAL « 0x0104011301e8 (6 bytes) 09:34:41.102 SERIAL » [ACK] (0x06) 09:34:41.102 DRIVER « [RES] [SendData] was sent: true 09:34:42.115 CNTRLR [Node 025] Beginning interview - last completed stage: RestartFromCache 09:34:42.116 CNTRLR » [Node 025] pinging the node... 09:34:42.620 SERIAL « 0x01070013c3000098b0 (9 bytes) 09:34:42.620 SERIAL » [ACK] (0x06) 09:34:42.621 DRIVER « [REQ] [SendData] callback id: 195 transmit status: OK 09:34:42.736 SERIAL « 0x010d0004001607600d0100400301c9 (15 bytes) 09:34:42.738 CNTRLR [Node 022] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 09:34:42.739 SERIAL » [ACK] (0x06) 09:34:42.742 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 09:34:42.748 SERIAL » 0x0108001319010025c41d (10 bytes) 09:34:42.749 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 196 └─[NoOperationCC] 09:34:42.750 CNTRLR « [Node 022] received current thermostat mode: Heat [Endpoint 1] 09:34:42.751 CNTRLR [Node 022] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 1] [internal] ue => true 09:34:42.834 SERIAL « [ACK] (0x06) 09:34:42.835 SERIAL « 0x0104011301e8 (6 bytes) 09:34:42.836 SERIAL » [ACK] (0x06) 09:34:42.844 DRIVER « [RES] [SendData] was sent: true 09:34:42.847 SERIAL « 0x01070013c400000728 (9 bytes) 09:34:42.847 SERIAL » [ACK] (0x06) 09:34:42.850 CNTRLR [Node 022] ThermostatSetpointCC: doing a partial interview... [Endpoint 1] 09:34:42.850 CNTRLR » [Node 022] querying current value of setpoint Heating... [Endpoint 1] 09:34:42.857 DRIVER « [REQ] [SendData] callback id: 196 transmit status: OK 09:34:42.867 SERIAL » 0x010a0013170360090125c57a (12 bytes) 09:34:42.868 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 197 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:34:42.869 CNTRLR « [Node 025] ping successful 09:34:42.872 CNTRLR [Node 025] ManufacturerSpecificCC: doing a partial interview... 09:34:42.873 CNTRLR [Node 025] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:34:42.874 CNTRLR [Node 025] VersionCC: doing a partial interview... 09:34:42.875 CNTRLR [Node 025] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:34:42.876 CNTRLR [Node 025] trying to load device config 09:34:42.882 SERIAL « [ACK] (0x06) 09:34:42.883 SERIAL « 0x0104011301e8 (6 bytes) 09:34:42.883 SERIAL » [ACK] (0x06) 09:34:42.884 DRIVER « [RES] [SendData] was sent: true 09:34:42.897 CNTRLR [Node 025] device config loaded 09:34:42.898 CNTRLR » [Node 025] querying device endpoint information... 09:34:43.081 SERIAL « 0x01070013c50000153b (9 bytes) 09:34:43.081 SERIAL » [ACK] (0x06) 09:34:43.082 DRIVER « [REQ] [SendData] callback id: 197 transmit status: OK 09:34:43.188 SERIAL « 0x010c0004001706600a01100125b9 (14 bytes) 09:34:43.188 CNTRLR [Node 023] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 1] [internal] 7 09:34:43.189 SERIAL » [ACK] (0x06) 09:34:43.190 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:34:43.193 SERIAL » 0x010900131902600725c67a (11 bytes) 09:34:43.193 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 198 └─[MultiChannelCCEndPointGet] 09:34:43.194 CNTRLR « [Node 023] received response for endpoint capabilities (#1): generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:34:43.194 CNTRLR [Node 023] all endpoints idendical, skipping capability query for endpoint #2. .. 09:34:43.194 CNTRLR [Node 023] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 2] [internal] 7 09:34:43.195 CNTRLR [Node 023] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:34:43.195 CNTRLR [Node 023] WakeUpCC: doing a complete interview... 09:34:43.195 CNTRLR » [Node 023] retrieving wakeup interval from the device... 09:34:43.198 SERIAL « [ACK] (0x06) 09:34:43.201 SERIAL « 0x0104011301e8 (6 bytes) 09:34:43.201 SERIAL » [ACK] (0x06) 09:34:43.202 DRIVER « [RES] [SendData] was sent: true 09:34:43.276 SERIAL « 0x01070013c600000825 (9 bytes) 09:34:43.276 SERIAL » [ACK] (0x06) 09:34:43.277 DRIVER « [REQ] [SendData] callback id: 198 transmit status: OK 09:34:43.286 SERIAL « 0x010a000400190460084002c6 (12 bytes) 09:34:43.287 CNTRLR [Node 025] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:34:43.287 CNTRLR [Node 025] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 09:34:43.287 CNTRLR [Node 025] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:34:43.287 SERIAL » [ACK] (0x06) 09:34:43.288 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:34:43.291 SERIAL » 0x010900131702840525c793 (11 bytes) 09:34:43.292 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 199 └─[WakeUpCCIntervalGet] 09:34:43.292 CNTRLR « [Node 025] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:34:43.293 CNTRLR [Node 025] does not support EndPointFind, assuming that endpoints are sequenti al 09:34:43.293 CNTRLR » [Node 025] querying capabilities for endpoint #1... 09:34:43.296 SERIAL « [ACK] (0x06) 09:34:43.300 SERIAL « 0x0104011301e8 (6 bytes) 09:34:43.300 SERIAL » [ACK] (0x06) 09:34:43.301 DRIVER « [RES] [SendData] was sent: true 09:34:43.480 SERIAL « 0x01070013c70000123e (9 bytes) 09:34:43.481 SERIAL » [ACK] (0x06) 09:34:43.483 DRIVER « [REQ] [SendData] callback id: 199 transmit status: OK 09:34:43.518 SERIAL « 0x010c00040003063105042204b155 (14 bytes) 09:34:43.519 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:34:43.520 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 135.5 => 120.1 [Endpoint 0] 09:34:43.520 SERIAL » [ACK] (0x06) 09:34:43.521 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 120.1 09:34:45.087 CNTRLR [Node 023] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:34:45.283 SERIAL « 0x010c0004000306310504220624c2 (14 bytes) 09:34:45.285 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:34:45.286 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 120.1 => 157.2 [Endpoint 0] 09:34:45.287 SERIAL » [ACK] (0x06) 09:34:45.290 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 157.2 09:34:45.594 SERIAL » 0x010900131702840525c793 (11 bytes) 09:34:45.595 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 199 └─[WakeUpCCIntervalGet] 09:34:45.597 SERIAL « [ACK] (0x06) 09:34:45.603 SERIAL « 0x0104011301e8 (6 bytes) 09:34:45.604 SERIAL » [ACK] (0x06) 09:34:45.605 DRIVER « [RES] [SendData] was sent: true 09:34:45.700 SERIAL « 0x01070013c700000a26 (9 bytes) 09:34:45.700 SERIAL » [ACK] (0x06) 09:34:45.701 DRIVER « [REQ] [SendData] callback id: 199 transmit status: OK 09:34:46.282 SERIAL « 0x010c000400030631050422048c68 (14 bytes) 09:34:46.283 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:34:46.284 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 157.2 => 116.4 [Endpoint 0] 09:34:46.284 SERIAL » [ACK] (0x06) 09:34:46.286 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 116.4 09:34:46.336 DRIVER The awake timeout for node 27 has elapsed. Assuming it is asleep. 09:34:46.337 CNTRLR [Node 027] The node is now asleep. 09:34:46.339 CNTRLR [Node 027] ping failed: The node is asleep 09:34:46.341 CNTRLR [Node 027] ManufacturerSpecificCC: doing a partial interview... 09:34:46.342 CNTRLR [Node 027] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:34:46.373 CNTRLR [Node 027] VersionCC: doing a partial interview... 09:34:46.374 CNTRLR [Node 027] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:34:46.374 CNTRLR [Node 027] trying to load device config 09:34:46.389 CNTRLR [Node 027] device config loaded 09:34:46.389 CNTRLR [Node 027] BatteryCC: doing a partial interview... 09:34:46.390 CNTRLR » [Node 027] querying battery status... 09:34:47.309 CNTRLR [Node 023] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:34:47.815 SERIAL » 0x010900131702840525c793 (11 bytes) 09:34:47.816 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 199 └─[WakeUpCCIntervalGet] 09:34:47.818 SERIAL « [ACK] (0x06) 09:34:47.824 SERIAL « 0x0104011301e8 (6 bytes) 09:34:47.825 SERIAL » [ACK] (0x06) 09:34:47.826 DRIVER « [RES] [SendData] was sent: true 09:34:47.921 SERIAL « 0x01070013c700000b27 (9 bytes) 09:34:47.921 SERIAL » [ACK] (0x06) 09:34:47.922 DRIVER « [REQ] [SendData] callback id: 199 transmit status: OK 09:34:49.529 SERIAL » 0x010a0013190360090125c879 (12 bytes) 09:34:49.529 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 200 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:34:49.530 CNTRLR [Node 023] Interview attempt 4/5 failed, retrying in 20000 ms... 09:34:49.531 SERIAL « [ACK] (0x06) 09:34:49.537 SERIAL « 0x0104011301e8 (6 bytes) 09:34:49.537 SERIAL » [ACK] (0x06) 09:34:49.538 DRIVER « [RES] [SendData] was sent: true 09:34:49.555 SERIAL « 0x01070013c800000221 (9 bytes) 09:34:49.555 SERIAL » [ACK] (0x06) 09:34:49.556 DRIVER « [REQ] [SendData] callback id: 200 transmit status: OK 09:34:49.566 SERIAL « 0x010c0004001906600a01100125b7 (14 bytes) 09:34:49.566 CNTRLR [Node 025] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 1] [internal] 7 09:34:49.566 SERIAL » [ACK] (0x06) 09:34:49.567 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:34:49.570 SERIAL » 0x010d00131806600d0002250225c95b (15 bytes) 09:34:49.570 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 201 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[BinarySwitchCCGet] 09:34:49.571 CNTRLR « [Node 025] received response for endpoint capabilities (#1): generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:34:49.571 CNTRLR [Node 025] all endpoints idendical, skipping capability query for endpoint #2. .. 09:34:49.572 CNTRLR [Node 025] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 2] [internal] 7 09:34:49.572 CNTRLR [Node 025] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:34:49.572 CNTRLR [Node 025] WakeUpCC: doing a complete interview... 09:34:49.572 CNTRLR » [Node 025] retrieving wakeup interval from the device... 09:34:49.575 SERIAL « [ACK] (0x06) 09:34:49.579 SERIAL « 0x0104011301e8 (6 bytes) 09:34:49.579 SERIAL » [ACK] (0x06) 09:34:49.580 DRIVER « [RES] [SendData] was sent: true 09:34:49.600 SERIAL « 0x01070013c900000321 (9 bytes) 09:34:49.601 SERIAL » [ACK] (0x06) 09:34:49.601 DRIVER « [REQ] [SendData] callback id: 201 transmit status: OK 09:34:49.615 SERIAL « 0x010d0004001807600d02002503ff5f (15 bytes) 09:34:49.616 CNTRLR [Node 024] [~] [Binary Switch] currentValue: true => true [Endpoint 2] 09:34:49.616 SERIAL » [ACK] (0x06) 09:34:49.617 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BinarySwitchCCReport] current value: true 09:34:49.620 SERIAL » 0x010900131902840525ca90 (11 bytes) 09:34:49.621 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 202 └─[WakeUpCCIntervalGet] 09:34:49.621 CNTRLR « [Node 024] received Binary Switch state: [Endpoint 2] current value: true 09:34:49.622 CNTRLR [Node 024] [~] [Binary Switch] interviewComplete: true [Endpoint 2] [internal] => true 09:34:49.622 CNTRLR [Node 024] MeterCC: doing a partial interview... [Endpoint 2] 09:34:49.622 CNTRLR » [Node 024] querying default meter value... [Endpoint 2] 09:34:49.626 SERIAL « [ACK] (0x06) 09:34:49.629 SERIAL « 0x0104011301e8 (6 bytes) 09:34:49.629 SERIAL » [ACK] (0x06) 09:34:49.631 DRIVER « [RES] [SendData] was sent: true 09:34:49.646 SERIAL « 0x01070013ca00000223 (9 bytes) 09:34:49.646 SERIAL » [ACK] (0x06) 09:34:49.647 DRIVER « [REQ] [SendData] callback id: 202 transmit status: OK 09:34:51.250 CNTRLR [Node 025] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:34:51.756 SERIAL » 0x010900131902840525ca90 (11 bytes) 09:34:51.757 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 202 └─[WakeUpCCIntervalGet] 09:34:51.760 SERIAL « [ACK] (0x06) 09:34:51.766 SERIAL « 0x0104011301e8 (6 bytes) 09:34:51.766 SERIAL » [ACK] (0x06) 09:34:51.767 DRIVER « [RES] [SendData] was sent: true 09:34:51.783 SERIAL « 0x01070013ca00000223 (9 bytes) 09:34:51.783 SERIAL » [ACK] (0x06) 09:34:51.785 DRIVER « [REQ] [SendData] callback id: 202 transmit status: OK 09:34:53.388 CNTRLR [Node 025] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:34:53.893 SERIAL » 0x010900131902840525ca90 (11 bytes) 09:34:53.894 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 202 └─[WakeUpCCIntervalGet] 09:34:53.896 SERIAL « [ACK] (0x06) 09:34:53.902 SERIAL « 0x0104011301e8 (6 bytes) 09:34:53.903 SERIAL » [ACK] (0x06) 09:34:53.904 DRIVER « [RES] [SendData] was sent: true 09:34:53.920 SERIAL « 0x01070013ca00000322 (9 bytes) 09:34:53.920 SERIAL » [ACK] (0x06) 09:34:53.922 DRIVER « [REQ] [SendData] callback id: 202 transmit status: OK 09:34:55.537 SERIAL » 0x010a00131a0370050325cb67 (12 bytes) 09:34:55.538 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 203 └─[ConfigurationCCGet] parameter #: 3 09:34:55.539 CNTRLR [Node 025] Interview attempt 4/5 failed, retrying in 20000 ms... 09:34:55.541 SERIAL « [ACK] (0x06) 09:34:55.547 SERIAL « 0x0104011301e8 (6 bytes) 09:34:55.547 SERIAL » [ACK] (0x06) 09:34:55.548 DRIVER « [RES] [SendData] was sent: true 09:34:55.564 SERIAL « 0x01070013cb00000222 (9 bytes) 09:34:55.565 SERIAL » [ACK] (0x06) 09:34:55.566 DRIVER « [REQ] [SendData] callback id: 203 transmit status: OK 09:34:55.575 SERIAL « 0x010b0004001a0570060301009b (13 bytes) 09:34:55.587 CNTRLR [Node 026] [~] [Configuration] 3: 0 => 0 09:34:55.590 SERIAL » [ACK] (0x06) 09:34:55.592 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 09:34:55.628 SERIAL » 0x010900130602984025ccd0 (11 bytes) 09:34:55.629 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 204 └─[SecurityCCNonceGet] 09:34:55.630 CNTRLR « [Node 026] parameter #3 has value: 0 09:34:55.630 CNTRLR » [Node 026] querying parameter #10 value... 09:34:55.640 SERIAL « [ACK] (0x06) 09:34:55.641 SERIAL « 0x0104011301e8 (6 bytes) 09:34:55.641 SERIAL » [ACK] (0x06) 09:34:55.643 DRIVER « [RES] [SendData] was sent: true 09:34:56.888 SERIAL « 0x01070013cc00007d5a (9 bytes) 09:34:56.889 SERIAL » [ACK] (0x06) 09:34:56.890 DRIVER « [REQ] [SendData] callback id: 204 transmit status: OK 09:34:56.910 SERIAL « 0x0110000400060a988040aa38a3c5deae546f (18 bytes) 09:34:56.911 SERIAL » [ACK] (0x06) 09:34:56.913 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x40aa38a3c5deae54 09:34:56.924 SERIAL » 0x01210013061a9881cec6309ab7a1e01238791c4efb2a45406df42fbf0bb9ca0d2 (35 bytes) 5cddd 09:34:56.925 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 205 └─[SecurityCCCommandEncapsulation] │ nonce id: 64 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:34:56.929 SERIAL « [ACK] (0x06) 09:34:56.936 SERIAL « 0x0104011301e8 (6 bytes) 09:34:56.937 SERIAL » [ACK] (0x06) 09:34:56.938 DRIVER « [RES] [SendData] was sent: true 09:34:56.961 SERIAL « 0x01070013cd00000325 (9 bytes) 09:34:56.962 SERIAL » [ACK] (0x06) 09:34:56.963 DRIVER « [REQ] [SendData] callback id: 205 transmit status: OK 09:34:57.079 SERIAL « 0x0108000400060298402f (10 bytes) 09:34:57.080 SERIAL » [ACK] (0x06) 09:34:57.081 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:34:57.089 SERIAL » 0x01110013060a9880c1de8d433d63360824007c (19 bytes) 09:34:57.090 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xc1de8d433d633608 09:34:57.092 SERIAL « [ACK] (0x06) 09:34:57.099 SERIAL « 0x0104011301e8 (6 bytes) 09:34:57.099 SERIAL » [ACK] (0x06) 09:34:57.100 DRIVER « [RES] [SendData] was sent: true 09:34:57.141 SERIAL « 0x0121000400061b98818938624ac4356b9ce4effeaf44108c46c13c3db993b2ad1 (35 bytes) c6b07 09:34:57.142 SERIAL » [ACK] (0x06) 09:34:57.144 CNTRLR [Node 006] [~] [Thermostat Mode] mode: 0 => 0 [Endpoint 1] 09:34:57.146 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Off 09:34:57.151 SERIAL » 0x010d00131206600d0001400225ce30 (15 bytes) 09:34:57.152 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 206 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:34:57.154 CNTRLR « [Node 006] received current thermostat mode: Off [Endpoint 1] 09:34:57.155 CNTRLR [Node 006] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 1] [internal] ue => true 09:34:57.221 SERIAL « [ACK] (0x06) 09:34:57.227 SERIAL « 0x0104011301e8 (6 bytes) 09:34:57.227 SERIAL » [ACK] (0x06) 09:34:57.230 DRIVER « [RES] [SendData] was sent: true 09:34:57.235 CNTRLR [Node 006] ThermostatSetpointCC: doing a partial interview... [Endpoint 1] 09:34:57.235 CNTRLR » [Node 006] querying current value of setpoint Heating... [Endpoint 1] 09:34:57.240 SERIAL « 0x01070013ce00000623 (9 bytes) 09:34:57.240 SERIAL » [ACK] (0x06) 09:34:57.241 DRIVER « [REQ] [SendData] callback id: 206 transmit status: OK 09:34:58.845 CNTRLR [Node 018] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:34:59.354 SERIAL » 0x010d00131206600d0001400225ce30 (15 bytes) 09:34:59.356 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 206 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:34:59.358 SERIAL « [ACK] (0x06) 09:34:59.364 SERIAL « 0x0104011301e8 (6 bytes) 09:34:59.365 SERIAL » [ACK] (0x06) 09:34:59.366 DRIVER « [RES] [SendData] was sent: true 09:34:59.414 SERIAL « 0x01070013ce00000623 (9 bytes) 09:34:59.414 SERIAL » [ACK] (0x06) 09:34:59.415 DRIVER « [REQ] [SendData] callback id: 206 transmit status: OK 09:35:00.283 SERIAL « 0x010c0004000306310504220ae208 (14 bytes) 09:35:00.284 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:35:00.285 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 116.4 => 278.6 [Endpoint 0] 09:35:00.285 SERIAL » [ACK] (0x06) 09:35:00.286 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 278.6 09:35:01.021 CNTRLR [Node 018] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:35:01.524 SERIAL » 0x010d00131206600d0001400225ce30 (15 bytes) 09:35:01.524 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 206 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:35:01.526 SERIAL « [ACK] (0x06) 09:35:01.532 SERIAL « 0x0104011301e8 (6 bytes) 09:35:01.533 SERIAL » [ACK] (0x06) 09:35:01.533 DRIVER « [RES] [SendData] was sent: true 09:35:01.581 SERIAL « 0x01070013ce00000623 (9 bytes) 09:35:01.582 SERIAL » [ACK] (0x06) 09:35:01.582 DRIVER « [REQ] [SendData] callback id: 206 transmit status: OK 09:35:03.194 SERIAL » 0x010a0013130370053225cf5b (12 bytes) 09:35:03.195 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 207 └─[ConfigurationCCGet] parameter #: 50 09:35:03.196 CNTRLR [Node 018] Interview attempt 4/5 failed, retrying in 20000 ms... 09:35:03.198 SERIAL « [ACK] (0x06) 09:35:03.204 SERIAL « 0x0104011301e8 (6 bytes) 09:35:03.204 SERIAL » [ACK] (0x06) 09:35:03.205 DRIVER « [RES] [SendData] was sent: true 09:35:03.251 SERIAL « 0x01070013cf00000622 (9 bytes) 09:35:03.251 SERIAL » [ACK] (0x06) 09:35:03.252 DRIVER « [REQ] [SendData] callback id: 207 transmit status: OK 09:35:03.302 SERIAL « 0x010b00040013057006320100a3 (13 bytes) 09:35:03.313 CNTRLR [Node 019] [~] [Configuration] 50: 0 => 0 09:35:03.315 SERIAL » [ACK] (0x06) 09:35:03.316 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 0 09:35:03.322 SERIAL » 0x010e00131607600d000143020125d02a (16 bytes) 09:35:03.323 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 208 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:35:03.323 CNTRLR « [Node 019] parameter #50 has value: 0 09:35:03.324 CNTRLR [Node 019] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 09:35:03.375 SERIAL « [ACK] (0x06) 09:35:03.382 SERIAL « 0x0104011301e8 (6 bytes) 09:35:03.382 SERIAL » [ACK] (0x06) 09:35:03.387 DRIVER « [RES] [SendData] was sent: true 09:35:03.389 CNTRLR [Node 019] ProtectionCC: doing a partial interview... 09:35:03.389 CNTRLR » [Node 019] querying protection status... 09:35:04.720 SERIAL « 0x01070013d000008cb7 (9 bytes) 09:35:04.721 SERIAL » [ACK] (0x06) 09:35:04.722 DRIVER « [REQ] [SendData] callback id: 208 transmit status: OK 09:35:04.842 SERIAL « 0x0110000400160a600d01004303012200d22a (18 bytes) 09:35:04.845 CNTRLR [Node 022] [~] [Thermostat Setpoint] setpoint[1]: 21 => 21 [Endpoint 1] 09:35:04.846 CNTRLR [Node 022] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 09:35:04.847 SERIAL » [ACK] (0x06) 09:35:04.849 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 21 °C 09:35:04.859 SERIAL » 0x010800131c010025d10d (10 bytes) 09:35:04.860 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 209 └─[NoOperationCC] 09:35:04.861 CNTRLR « [Node 022] received current value of setpoint Heating: 21 °C [Endpoint 1] 09:35:04.862 CNTRLR [Node 022] [~] [Thermostat Setpoint] interviewComplete [Endpoint 1] [internal] : true => true 09:35:04.939 SERIAL « [ACK] (0x06) 09:35:04.948 SERIAL « 0x0104011301e8 (6 bytes) 09:35:04.948 SERIAL » [ACK] (0x06) 09:35:04.948 DRIVER « [RES] [SendData] was sent: true 09:35:04.952 CNTRLR [Node 022] NotificationCC: doing a partial interview... [Endpoint 1] 09:35:04.953 CNTRLR [Node 022] [~] [Notification] interviewComplete: true [Endpoint 1] [internal] => true 09:35:04.953 CNTRLR [Node 022] ProtectionCC: doing a partial interview... 09:35:04.953 CNTRLR » [Node 022] querying protection status... 09:35:06.279 SERIAL « 0x01070013d100008db7 (9 bytes) 09:35:06.280 SERIAL » [ACK] (0x06) 09:35:06.281 DRIVER « [REQ] [SendData] callback id: 209 transmit status: OK 09:35:06.289 SERIAL » 0x010800131d010025d20f (10 bytes) 09:35:06.289 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 210 └─[NoOperationCC] 09:35:06.290 CNTRLR « [Node 028] ping successful 09:35:06.295 CNTRLR [Node 028] ManufacturerSpecificCC: doing a partial interview... 09:35:06.295 CNTRLR [Node 028] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:35:06.347 SERIAL « [ACK] (0x06) 09:35:06.420 CNTRLR [Node 028] VersionCC: doing a partial interview... 09:35:06.420 CNTRLR [Node 028] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:35:06.421 CNTRLR [Node 028] trying to load device config 09:35:06.425 CNTRLR [Node 028] device config loaded 09:35:06.426 CNTRLR [Node 028] ZWavePlusCC: doing a partial interview... 09:35:06.426 CNTRLR [Node 028] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:35:06.427 CNTRLR » [Node 028] querying device endpoint information... 09:35:06.791 SERIAL « 0x0104011301e8 (6 bytes) 09:35:06.791 SERIAL » [ACK] (0x06) 09:35:06.792 DRIVER « [RES] [SendData] was sent: true 09:35:08.285 SERIAL « 0x010c0004000306310504220610f6 (14 bytes) 09:35:08.286 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:35:08.287 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 278.6 => 155.2 [Endpoint 0] 09:35:08.288 SERIAL » [ACK] (0x06) 09:35:08.290 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 155.2 09:35:09.531 CNTRLR [Node 023] Beginning interview - last completed stage: RestartFromCache 09:35:09.531 CNTRLR » [Node 023] pinging the node... 09:35:10.285 SERIAL « 0x010c0004000306310504220941a8 (14 bytes) 09:35:10.286 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:35:10.286 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 155.2 => 236.9 [Endpoint 0] 09:35:10.287 SERIAL » [ACK] (0x06) 09:35:10.288 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 236.9 09:35:11.361 SERIAL « 0x010c00040003063105042206e006 (14 bytes) 09:35:11.363 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:35:11.364 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 236.9 => 176 [Endpoint 0] 09:35:11.365 SERIAL » [ACK] (0x06) 09:35:11.367 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 176 09:35:12.285 SERIAL « 0x010c000400030631050422086b83 (14 bytes) 09:35:12.287 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:35:12.288 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 176 => 215.5 [Endpoint 0] 09:35:12.289 SERIAL » [ACK] (0x06) 09:35:12.291 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 215.5 09:35:14.285 SERIAL « 0x010c0004000306310504220550b5 (14 bytes) 09:35:14.287 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:35:14.288 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 215.5 => 136 [Endpoint 0] 09:35:14.289 SERIAL » [ACK] (0x06) 09:35:14.291 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 136 09:35:15.540 CNTRLR [Node 025] Beginning interview - last completed stage: RestartFromCache 09:35:15.541 CNTRLR » [Node 025] pinging the node... 09:35:16.230 SERIAL « 0x01070013d20003e2d8 (9 bytes) 09:35:16.231 SERIAL » [ACK] (0x06) 09:35:16.232 DRIVER « [REQ] [SendData] callback id: 210 transmit status: OK 09:35:16.240 SERIAL » 0x0108001317010025d304 (10 bytes) 09:35:16.240 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 211 └─[NoOperationCC] 09:35:16.241 CNTRLR « [Node 029] ping successful 09:35:16.245 CNTRLR [Node 029] ManufacturerSpecificCC: doing a partial interview... 09:35:16.246 CNTRLR [Node 029] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:35:16.320 SERIAL « [ACK] (0x06) 09:35:16.326 SERIAL « 0x0104011301e8 (6 bytes) 09:35:16.326 SERIAL » [ACK] (0x06) 09:35:16.328 DRIVER « [RES] [SendData] was sent: true 09:35:16.329 CNTRLR [Node 029] VersionCC: doing a partial interview... 09:35:16.330 CNTRLR [Node 029] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:35:16.330 CNTRLR [Node 029] trying to load device config 09:35:16.333 CNTRLR [Node 029] device config loaded 09:35:16.334 CNTRLR [Node 029] ZWavePlusCC: doing a partial interview... 09:35:16.334 CNTRLR [Node 029] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:35:16.334 CNTRLR » [Node 029] querying device endpoint information... 09:35:16.344 SERIAL « 0x01070013d300000a32 (9 bytes) 09:35:16.344 SERIAL » [ACK] (0x06) 09:35:16.345 DRIVER « [REQ] [SendData] callback id: 211 transmit status: OK 09:35:16.349 SERIAL » 0x0108001319010025d40d (10 bytes) 09:35:16.349 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 212 └─[NoOperationCC] 09:35:16.350 CNTRLR « [Node 023] ping successful 09:35:16.351 CNTRLR [Node 023] ManufacturerSpecificCC: doing a partial interview... 09:35:16.351 CNTRLR [Node 023] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:35:16.351 CNTRLR [Node 023] VersionCC: doing a partial interview... 09:35:16.351 CNTRLR [Node 023] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:35:16.352 CNTRLR [Node 023] trying to load device config 09:35:16.356 SERIAL « [ACK] (0x06) 09:35:16.357 SERIAL « 0x0104011301e8 (6 bytes) 09:35:16.358 SERIAL » [ACK] (0x06) 09:35:16.358 DRIVER « [RES] [SendData] was sent: true 09:35:16.369 CNTRLR [Node 023] device config loaded 09:35:16.370 CNTRLR » [Node 023] querying device endpoint information... 09:35:16.374 SERIAL « 0x01070013d40000023d (9 bytes) 09:35:16.375 SERIAL » [ACK] (0x06) 09:35:16.375 DRIVER « [REQ] [SendData] callback id: 212 transmit status: OK 09:35:16.379 SERIAL » 0x010900131d02600725d56d (11 bytes) 09:35:16.379 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 213 └─[MultiChannelCCEndPointGet] 09:35:16.380 CNTRLR « [Node 025] ping successful 09:35:16.381 CNTRLR [Node 025] ManufacturerSpecificCC: doing a partial interview... 09:35:16.381 CNTRLR [Node 025] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:35:16.381 CNTRLR [Node 025] VersionCC: doing a partial interview... 09:35:16.382 CNTRLR [Node 025] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:35:16.382 CNTRLR [Node 025] trying to load device config 09:35:16.384 SERIAL « [ACK] (0x06) 09:35:16.398 CNTRLR [Node 025] device config loaded 09:35:16.399 CNTRLR » [Node 025] querying device endpoint information... 09:35:16.401 SERIAL « 0x0104011301e8 (6 bytes) 09:35:16.401 SERIAL » [ACK] (0x06) 09:35:16.402 DRIVER « [RES] [SendData] was sent: true 09:35:16.445 SERIAL « 0x01070013d500000638 (9 bytes) 09:35:16.445 SERIAL » [ACK] (0x06) 09:35:16.446 DRIVER « [REQ] [SendData] callback id: 213 transmit status: OK 09:35:16.532 SERIAL « 0x010b0004001d05600800020082 (13 bytes) 09:35:16.533 CNTRLR [Node 029] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:35:16.533 CNTRLR [Node 029] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 09:35:16.534 CNTRLR [Node 029] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:35:16.534 CNTRLR [Node 029] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 09:35:16.534 SERIAL » [ACK] (0x06) 09:35:16.535 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:35:16.538 SERIAL » 0x010900131702600725d664 (11 bytes) 09:35:16.538 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 214 └─[MultiChannelCCEndPointGet] 09:35:16.539 CNTRLR « [Node 029] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:35:16.539 CNTRLR » [Node 029] querying all endpoints... 09:35:16.542 SERIAL « [ACK] (0x06) 09:35:16.546 SERIAL « 0x0104011301e8 (6 bytes) 09:35:16.546 SERIAL » [ACK] (0x06) 09:35:16.547 DRIVER « [RES] [SendData] was sent: true 09:35:16.706 SERIAL « 0x01070013d60000102d (9 bytes) 09:35:16.707 SERIAL » [ACK] (0x06) 09:35:16.707 DRIVER « [REQ] [SendData] callback id: 214 transmit status: OK 09:35:16.741 SERIAL « 0x0112000400180c600d02003202213203610000d3 (20 bytes) 09:35:16.742 CNTRLR [Node 024] [~] [Meter] value[66049]: 111.6 => 86.5 [Endpoint 2] 09:35:16.743 CNTRLR [Node 024] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 2] 09:35:16.744 SERIAL » [ACK] (0x06) 09:35:16.747 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 86.5 time delta: 0 seconds 09:35:16.852 SERIAL « 0x010a000400170460084002c8 (12 bytes) 09:35:16.853 CNTRLR [Node 023] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:35:16.853 CNTRLR [Node 023] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 09:35:16.854 CNTRLR [Node 023] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:35:16.854 SERIAL » [ACK] (0x06) 09:35:16.855 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:35:16.859 SERIAL » 0x010900131902600725d76b (11 bytes) 09:35:16.860 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 215 └─[MultiChannelCCEndPointGet] 09:35:16.861 CNTRLR « [Node 023] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:35:16.862 CNTRLR [Node 023] does not support EndPointFind, assuming that endpoints are sequenti al 09:35:16.862 CNTRLR » [Node 023] querying capabilities for endpoint #1... 09:35:16.867 SERIAL « [ACK] (0x06) 09:35:16.869 SERIAL « 0x0104011301e8 (6 bytes) 09:35:16.869 SERIAL » [ACK] (0x06) 09:35:16.870 DRIVER « [RES] [SendData] was sent: true 09:35:16.946 SERIAL « 0x01070013d700000834 (9 bytes) 09:35:16.946 SERIAL » [ACK] (0x06) 09:35:16.947 DRIVER « [REQ] [SendData] callback id: 215 transmit status: OK 09:35:16.956 SERIAL « 0x010a000400190460084002c6 (12 bytes) 09:35:16.958 CNTRLR [Node 025] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:35:16.958 CNTRLR [Node 025] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 09:35:16.958 CNTRLR [Node 025] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:35:16.959 SERIAL » [ACK] (0x06) 09:35:16.960 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:35:16.965 SERIAL » 0x010b00131d04600bffff25d868 (13 bytes) 09:35:16.966 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 216 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:35:16.966 CNTRLR « [Node 025] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:35:16.967 CNTRLR [Node 025] does not support EndPointFind, assuming that endpoints are sequenti al 09:35:16.967 CNTRLR » [Node 025] querying capabilities for endpoint #1... 09:35:16.972 SERIAL « [ACK] (0x06) 09:35:16.974 SERIAL « 0x0104011301e8 (6 bytes) 09:35:16.974 SERIAL » [ACK] (0x06) 09:35:16.975 DRIVER « [RES] [SendData] was sent: true 09:35:18.366 SERIAL « 0x01070013d800008cbf (9 bytes) 09:35:18.366 SERIAL » [ACK] (0x06) 09:35:18.367 DRIVER « [REQ] [SendData] callback id: 216 transmit status: OK 09:35:18.448 SERIAL « 0x010d0004001d07600c00ffff010283 (15 bytes) 09:35:18.449 SERIAL » [ACK] (0x06) 09:35:18.451 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 09:35:18.458 SERIAL » 0x010a0013170360090125d966 (12 bytes) 09:35:18.459 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 217 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:35:18.460 CNTRLR « [Node 029] received endpoints: 1, 2 09:35:18.461 CNTRLR » [Node 029] querying capabilities for endpoint #1... 09:35:18.466 SERIAL « [ACK] (0x06) 09:35:18.469 SERIAL « 0x0104011301e8 (6 bytes) 09:35:18.469 SERIAL » [ACK] (0x06) 09:35:18.470 DRIVER « [RES] [SendData] was sent: true 09:35:18.626 SERIAL « 0x01070013d900001022 (9 bytes) 09:35:18.627 SERIAL » [ACK] (0x06) 09:35:18.628 DRIVER « [REQ] [SendData] callback id: 217 transmit status: OK 09:35:18.749 SERIAL « 0x010c0004001706600a01100125b9 (14 bytes) 09:35:18.751 CNTRLR [Node 023] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 1] [internal] 7 09:35:18.751 SERIAL » [ACK] (0x06) 09:35:18.759 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:35:18.766 SERIAL » 0x010a0013190360090125da6b (12 bytes) 09:35:18.767 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 218 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:35:18.768 CNTRLR « [Node 023] received response for endpoint capabilities (#1): generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:35:18.768 CNTRLR [Node 023] all endpoints idendical, skipping capability query for endpoint #2. .. 09:35:18.769 CNTRLR [Node 023] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 2] [internal] 7 09:35:18.770 CNTRLR [Node 023] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:35:18.837 SERIAL « [ACK] (0x06) 09:35:18.840 SERIAL « 0x0104011301e8 (6 bytes) 09:35:18.841 SERIAL » [ACK] (0x06) 09:35:18.841 DRIVER « [RES] [SendData] was sent: true 09:35:18.846 CNTRLR [Node 023] WakeUpCC: doing a complete interview... 09:35:18.846 CNTRLR » [Node 023] retrieving wakeup interval from the device... 09:35:18.848 SERIAL « 0x01070013da00000637 (9 bytes) 09:35:18.849 SERIAL » [ACK] (0x06) 09:35:18.849 DRIVER « [REQ] [SendData] callback id: 218 transmit status: OK 09:35:18.851 SERIAL « 0x010c0004001906600a01100125b7 (14 bytes) 09:35:18.852 CNTRLR [Node 025] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 1] [internal] 7 09:35:18.852 SERIAL » [ACK] (0x06) 09:35:18.853 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:35:18.856 SERIAL » 0x010a00131d0360090125db6e (12 bytes) 09:35:18.856 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 219 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:35:18.857 CNTRLR « [Node 025] received response for endpoint capabilities (#1): generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:35:18.857 CNTRLR [Node 025] all endpoints idendical, skipping capability query for endpoint #2. .. 09:35:18.857 CNTRLR [Node 025] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 2] [internal] 7 09:35:18.857 CNTRLR [Node 025] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:35:18.858 CNTRLR [Node 025] WakeUpCC: doing a complete interview... 09:35:18.858 CNTRLR » [Node 025] retrieving wakeup interval from the device... 09:35:18.862 SERIAL « [ACK] (0x06) 09:35:18.864 SERIAL « 0x0104011301e8 (6 bytes) 09:35:18.865 SERIAL » [ACK] (0x06) 09:35:18.865 DRIVER « [RES] [SendData] was sent: true 09:35:20.307 SERIAL « 0x01070013db000091a1 (9 bytes) 09:35:20.308 SERIAL » [ACK] (0x06) 09:35:20.309 DRIVER « [REQ] [SendData] callback id: 219 transmit status: OK 09:35:20.396 SERIAL « 0x011a0004001d14600a0108065e8e404353989f596c7175808185229d (28 bytes) 09:35:20.397 CNTRLR [Node 029] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 1] [internal] 64,67,83,152,159,89,108,113,117,128,129,133,34 => 94,142,64,67,83,152,159,89,1 08,113,117,128,129,133,34 09:35:20.397 SERIAL » [ACK] (0x06) 09:35:20.399 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:35:20.404 SERIAL » 0x010900131702840525dc88 (11 bytes) 09:35:20.405 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 220 └─[WakeUpCCIntervalGet] 09:35:20.407 CNTRLR « [Node 029] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:35:20.408 CNTRLR » [Node 029] querying capabilities for endpoint #2... 09:35:20.411 SERIAL « [ACK] (0x06) 09:35:20.417 SERIAL « 0x0104011301e8 (6 bytes) 09:35:20.418 SERIAL » [ACK] (0x06) 09:35:20.418 DRIVER « [RES] [SendData] was sent: true 09:35:20.565 SERIAL « 0x01070013dc00001027 (9 bytes) 09:35:20.566 SERIAL » [ACK] (0x06) 09:35:20.566 DRIVER « [REQ] [SendData] callback id: 220 transmit status: OK 09:35:21.286 SERIAL « 0x010c0004000306310504220af01a (14 bytes) 09:35:21.287 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:35:21.288 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 136 => 280 [Endpoint 0] 09:35:21.289 SERIAL » [ACK] (0x06) 09:35:21.290 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 280 09:35:22.170 CNTRLR [Node 023] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:35:22.676 SERIAL » 0x010900131702840525dc88 (11 bytes) 09:35:22.677 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 220 └─[WakeUpCCIntervalGet] 09:35:22.679 SERIAL « [ACK] (0x06) 09:35:22.685 SERIAL « 0x0104011301e8 (6 bytes) 09:35:22.685 SERIAL » [ACK] (0x06) 09:35:22.686 DRIVER « [RES] [SendData] was sent: true 09:35:22.782 SERIAL « 0x01070013dc00000a3d (9 bytes) 09:35:22.782 SERIAL » [ACK] (0x06) 09:35:22.783 DRIVER « [REQ] [SendData] callback id: 220 transmit status: OK 09:35:23.197 CNTRLR [Node 018] Beginning interview - last completed stage: RestartFromCache 09:35:23.198 CNTRLR » [Node 018] pinging the node... 09:35:24.387 CNTRLR [Node 023] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:35:24.893 SERIAL » 0x010900131702840525dc88 (11 bytes) 09:35:24.894 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 220 └─[WakeUpCCIntervalGet] 09:35:24.902 SERIAL « [ACK] (0x06) 09:35:24.904 SERIAL « 0x0104011301e8 (6 bytes) 09:35:24.905 SERIAL » [ACK] (0x06) 09:35:24.906 DRIVER « [RES] [SendData] was sent: true 09:35:24.998 SERIAL « 0x01070013dc00000a3d (9 bytes) 09:35:24.999 SERIAL » [ACK] (0x06) 09:35:24.999 DRIVER « [REQ] [SendData] callback id: 220 transmit status: OK 09:35:26.610 SERIAL » 0x0108001312010025dd0f (10 bytes) 09:35:26.611 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 221 └─[NoOperationCC] 09:35:26.611 CNTRLR [Node 023] Failed all interview attempts, giving up. 09:35:26.613 SERIAL « [ACK] (0x06) 09:35:26.619 SERIAL « 0x0104011301e8 (6 bytes) 09:35:26.620 SERIAL » [ACK] (0x06) 09:35:26.620 DRIVER « [RES] [SendData] was sent: true 09:35:26.663 SERIAL « 0x01070013dd00000533 (9 bytes) 09:35:26.664 SERIAL » [ACK] (0x06) 09:35:26.665 DRIVER « [REQ] [SendData] callback id: 221 transmit status: OK 09:35:26.673 SERIAL » 0x010900131902840525de84 (11 bytes) 09:35:26.673 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 222 └─[WakeUpCCIntervalGet] 09:35:26.674 CNTRLR « [Node 018] ping successful 09:35:26.679 CNTRLR [Node 018] ManufacturerSpecificCC: doing a partial interview... 09:35:26.679 CNTRLR [Node 018] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:35:26.742 SERIAL « [ACK] (0x06) 09:35:26.744 SERIAL « 0x0104011301e8 (6 bytes) 09:35:26.744 SERIAL » [ACK] (0x06) 09:35:26.750 DRIVER « [RES] [SendData] was sent: true 09:35:26.753 SERIAL « 0x01070013de00000237 (9 bytes) 09:35:26.754 SERIAL » [ACK] (0x06) 09:35:26.756 CNTRLR [Node 018] VersionCC: doing a partial interview... 09:35:26.756 CNTRLR [Node 018] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:35:26.757 CNTRLR [Node 018] trying to load device config 09:35:26.759 DRIVER « [REQ] [SendData] callback id: 222 transmit status: OK 09:35:26.764 SERIAL « 0x0112000400180c600d02003202213204460000f3 (20 bytes) 09:35:26.765 CNTRLR [Node 024] [~] [Meter] value[66049]: 86.5 => 109.4 [Endpoint 2] 09:35:26.766 CNTRLR [Node 024] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 2] 09:35:26.767 SERIAL » [ACK] (0x06) 09:35:26.769 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 109.4 time delta: 0 seconds 09:35:26.776 CNTRLR [Node 018] device config loaded 09:35:26.777 CNTRLR [Node 018] ZWavePlusCC: doing a partial interview... 09:35:26.778 CNTRLR [Node 018] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:35:26.778 CNTRLR » [Node 018] querying device endpoint information... 09:35:28.363 CNTRLR [Node 025] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:35:28.870 SERIAL » 0x010900131902840525de84 (11 bytes) 09:35:28.872 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 222 └─[WakeUpCCIntervalGet] 09:35:28.874 SERIAL « [ACK] (0x06) 09:35:28.881 SERIAL « 0x0104011301e8 (6 bytes) 09:35:28.881 SERIAL » [ACK] (0x06) 09:35:28.883 DRIVER « [RES] [SendData] was sent: true 09:35:28.899 SERIAL « 0x01070013de00000237 (9 bytes) 09:35:28.899 SERIAL » [ACK] (0x06) 09:35:28.901 DRIVER « [REQ] [SendData] callback id: 222 transmit status: OK 09:35:30.506 CNTRLR [Node 025] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:35:31.009 SERIAL » 0x010900131902840525de84 (11 bytes) 09:35:31.009 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 222 └─[WakeUpCCIntervalGet] 09:35:31.011 SERIAL « [ACK] (0x06) 09:35:31.017 SERIAL « 0x0104011301e8 (6 bytes) 09:35:31.017 SERIAL » [ACK] (0x06) 09:35:31.018 DRIVER « [RES] [SendData] was sent: true 09:35:31.034 SERIAL « 0x01070013de00000237 (9 bytes) 09:35:31.035 SERIAL » [ACK] (0x06) 09:35:31.035 DRIVER « [REQ] [SendData] callback id: 222 transmit status: OK 09:35:32.648 SERIAL » 0x010a00131d0360090225df69 (12 bytes) 09:35:32.649 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 223 └─[MultiChannelCCCapabilityGet] endpoint: 2 09:35:32.650 CNTRLR [Node 025] Failed all interview attempts, giving up. 09:35:32.653 SERIAL « [ACK] (0x06) 09:35:32.658 SERIAL « 0x0104011301e8 (6 bytes) 09:35:32.659 SERIAL » [ACK] (0x06) 09:35:32.660 DRIVER « [RES] [SendData] was sent: true 09:35:34.066 SERIAL « 0x01070013df00008db9 (9 bytes) 09:35:34.067 SERIAL » [ACK] (0x06) 09:35:34.068 DRIVER « [REQ] [SendData] callback id: 223 transmit status: OK 09:35:34.158 SERIAL « 0x01160004001d10600a0221015e8e31989f596c718085222d (24 bytes) 09:35:34.158 CNTRLR [Node 029] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 2] [internal] 49,152,159,89,108,113,128,133,34 => 94,142,49,152,159,89,108,113,128,133,34 09:35:34.159 SERIAL » [ACK] (0x06) 09:35:34.160 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:35:34.164 SERIAL » 0x010d00131806600d0002320125e066 (15 bytes) 09:35:34.166 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 224 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MeterCCGet] 09:35:34.167 CNTRLR « [Node 029] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:35:34.168 CNTRLR [Node 029] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:35:34.208 SERIAL « [ACK] (0x06) 09:35:34.214 SERIAL « 0x0104011301e8 (6 bytes) 09:35:34.215 SERIAL » [ACK] (0x06) 09:35:34.216 DRIVER « [RES] [SendData] was sent: true 09:35:34.219 CNTRLR [Node 029] BatteryCC: doing a partial interview... 09:35:34.219 CNTRLR » [Node 029] querying battery status... 09:35:34.250 SERIAL « 0x01070013e000000803 (9 bytes) 09:35:34.251 SERIAL » [ACK] (0x06) 09:35:34.251 DRIVER « [REQ] [SendData] callback id: 224 transmit status: OK 09:35:34.266 SERIAL « 0x0112000400180c600d02003202014400006a870a (20 bytes) 09:35:34.267 CNTRLR [Node 024] [~] [Meter] value[65536]: 272.68 => 272.71 [Endpoint 2] 09:35:34.268 CNTRLR [Node 024] [~] [Meter] deltaTime[65536]: 0 => 0 [Endpoint 2] 09:35:34.268 SERIAL » [ACK] (0x06) 09:35:34.269 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: kWh rate type: Unspecified value: 272.71 time delta: 0 seconds 09:35:34.272 SERIAL » 0x010900131d02800225e1bc (11 bytes) 09:35:34.272 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 225 └─[BatteryCCGet] 09:35:34.273 CNTRLR [Node 024] [~] [Meter] interviewComplete: true => true [Endpoint 2] [internal] 09:35:34.273 CNTRLR [Node 024] BinarySwitchCC: doing a partial interview... 09:35:34.274 CNTRLR » [Node 024] querying Binary Switch state... 09:35:34.277 SERIAL « [ACK] (0x06) 09:35:34.281 SERIAL « 0x0104011301e8 (6 bytes) 09:35:34.281 SERIAL » [ACK] (0x06) 09:35:34.282 DRIVER « [RES] [SendData] was sent: true 09:35:34.336 SERIAL « 0x01070013e10000060c (9 bytes) 09:35:34.336 SERIAL » [ACK] (0x06) 09:35:34.337 DRIVER « [REQ] [SendData] callback id: 225 transmit status: OK 09:35:34.437 SERIAL « 0x01090004001d038003630c (11 bytes) 09:35:34.438 CNTRLR [Node 029] [~] [Battery] level: 99 => 99 [Endpoint 0] 09:35:34.438 CNTRLR [Node 029] [~] [Battery] isLow: false => false [Endpoint 0] 09:35:34.438 SERIAL » [ACK] (0x06) 09:35:34.439 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 99 is low: false 09:35:34.444 SERIAL » 0x010a00131a0370050a25e247 (12 bytes) 09:35:34.444 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 226 └─[ConfigurationCCGet] parameter #: 10 09:35:34.445 CNTRLR « [Node 029] received response for battery information: level: 99 09:35:34.445 CNTRLR [Node 029] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:35:34.445 CNTRLR [Node 029] WakeUpCC: doing a complete interview... 09:35:34.446 CNTRLR [Node 029] skipping wakeup configuration for frequent listening device 09:35:34.446 CNTRLR [Node 029] [+] [Wake Up] interviewComplete: true [Endpoint 0] [internal] 09:35:34.448 CNTRLR [Node 029] ZWavePlusCC: doing a partial interview... [Endpoint 1] 09:35:34.448 CNTRLR [Node 029] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 09:35:34.448 CNTRLR [Node 029] ThermostatModeCC: doing a partial interview... [Endpoint 1] 09:35:34.448 CNTRLR » [Node 029] querying current thermostat mode... [Endpoint 1] 09:35:34.452 SERIAL « [ACK] (0x06) 09:35:34.453 SERIAL « 0x0104011301e8 (6 bytes) 09:35:34.453 SERIAL » [ACK] (0x06) 09:35:34.454 DRIVER « [RES] [SendData] was sent: true 09:35:34.526 SERIAL « 0x01070013e200000801 (9 bytes) 09:35:34.527 SERIAL » [ACK] (0x06) 09:35:34.527 DRIVER « [REQ] [SendData] callback id: 226 transmit status: OK 09:35:34.536 SERIAL « 0x010b0004001a0570060a010193 (13 bytes) 09:35:34.542 CNTRLR [Node 026] [~] [Configuration] 10: 1 => 1 09:35:34.542 SERIAL » [ACK] (0x06) 09:35:34.543 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 1 09:35:34.547 SERIAL » 0x010d00131d06600d0001400225e312 (15 bytes) 09:35:34.547 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 227 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:35:34.548 CNTRLR « [Node 026] parameter #10 has value: 1 09:35:34.548 CNTRLR » [Node 026] querying parameter #12 value... 09:35:34.551 SERIAL « [ACK] (0x06) 09:35:34.556 SERIAL « 0x0104011301e8 (6 bytes) 09:35:34.556 SERIAL » [ACK] (0x06) 09:35:34.557 DRIVER « [RES] [SendData] was sent: true 09:35:34.621 SERIAL « 0x01070013e30000060e (9 bytes) 09:35:34.622 SERIAL » [ACK] (0x06) 09:35:34.624 DRIVER « [REQ] [SendData] callback id: 227 transmit status: OK 09:35:34.693 SERIAL « 0x010d0004001d07600d0100400301c2 (15 bytes) 09:35:34.694 CNTRLR [Node 029] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 09:35:34.694 SERIAL » [ACK] (0x06) 09:35:34.696 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 09:35:34.705 SERIAL » 0x010900130602984025e4f8 (11 bytes) 09:35:34.705 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 228 └─[SecurityCCNonceGet] 09:35:34.706 CNTRLR « [Node 029] received current thermostat mode: Heat [Endpoint 1] 09:35:34.706 CNTRLR [Node 029] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 1] [internal] ue => true 09:35:34.707 CNTRLR [Node 029] ThermostatSetpointCC: doing a partial interview... [Endpoint 1] 09:35:34.707 CNTRLR » [Node 029] querying current value of setpoint Heating... [Endpoint 1] 09:35:34.710 SERIAL « [ACK] (0x06) 09:35:34.713 SERIAL « 0x0104011301e8 (6 bytes) 09:35:34.714 SERIAL » [ACK] (0x06) 09:35:34.714 DRIVER « [RES] [SendData] was sent: true 09:35:36.034 SERIAL « 0x01070013e40000858a (9 bytes) 09:35:36.035 SERIAL » [ACK] (0x06) 09:35:36.036 DRIVER « [REQ] [SendData] callback id: 228 transmit status: OK 09:35:36.056 SERIAL « 0x0110000400060a9880a42f06349ed730eed1 (18 bytes) 09:35:36.057 SERIAL » [ACK] (0x06) 09:35:36.058 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xa42f06349ed730ee 09:35:36.065 SERIAL » 0x01220013061b988106c407c3f60a2daa57f076fa93fc5c3fa4cb5974fcc07a678 (36 bytes) 025e5b3 09:35:36.066 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 229 └─[SecurityCCCommandEncapsulation] │ nonce id: 164 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:35:36.069 SERIAL « [ACK] (0x06) 09:35:36.077 SERIAL « 0x0104011301e8 (6 bytes) 09:35:36.077 SERIAL » [ACK] (0x06) 09:35:36.078 DRIVER « [RES] [SendData] was sent: true 09:35:36.102 SERIAL « 0x01070013e50000030d (9 bytes) 09:35:36.103 SERIAL » [ACK] (0x06) 09:35:36.103 DRIVER « [REQ] [SendData] callback id: 229 transmit status: OK 09:35:36.225 SERIAL « 0x0108000400060298402f (10 bytes) 09:35:36.225 SERIAL » [ACK] (0x06) 09:35:36.226 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:35:36.234 SERIAL » 0x01110013060a988052a5b6c9e5699971240021 (19 bytes) 09:35:36.235 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x52a5b6c9e5699971 09:35:36.237 SERIAL « [ACK] (0x06) 09:35:36.243 SERIAL « 0x0104011301e8 (6 bytes) 09:35:36.244 SERIAL » [ACK] (0x06) 09:35:36.245 DRIVER « [RES] [SendData] was sent: true 09:35:36.287 SERIAL « 0x0124000400061e988146b46313c57f4fa80209addae066c04b25daed52da5626f (38 bytes) 12e78fac304 09:35:36.288 SERIAL » [ACK] (0x06) 09:35:36.291 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 1] 09:35:36.292 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 09:35:36.293 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 09:35:36.305 SERIAL » 0x010e00131d07600d000143020125e617 (16 bytes) 09:35:36.306 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 230 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:35:36.307 CNTRLR « [Node 006] received current value of setpoint Heating: 10 °C [Endpoint 1] 09:35:36.308 CNTRLR [Node 006] [~] [Thermostat Setpoint] interviewComplete [Endpoint 1] [internal] : true => true 09:35:36.353 SERIAL « [ACK] (0x06) 09:35:36.356 SERIAL « 0x0104011301e8 (6 bytes) 09:35:36.356 SERIAL » [ACK] (0x06) 09:35:36.357 DRIVER « [RES] [SendData] was sent: true 09:35:36.360 CNTRLR [Node 006] NotificationCC: doing a partial interview... [Endpoint 1] 09:35:36.360 CNTRLR » [Node 006] querying notification status for Power Management... [Endpoint 1] 09:35:36.410 SERIAL « 0x01070013e600000a07 (9 bytes) 09:35:36.410 SERIAL » [ACK] (0x06) 09:35:36.411 DRIVER « [REQ] [SendData] callback id: 230 transmit status: OK 09:35:38.013 CNTRLR [Node 029] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:35:38.518 SERIAL » 0x010e00131d07600d000143020125e617 (16 bytes) 09:35:38.519 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 230 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:35:38.521 SERIAL « [ACK] (0x06) 09:35:38.528 SERIAL « 0x0104011301e8 (6 bytes) 09:35:38.528 SERIAL » [ACK] (0x06) 09:35:38.529 DRIVER « [RES] [SendData] was sent: true 09:35:38.583 SERIAL « 0x01070013e60000060b (9 bytes) 09:35:38.584 SERIAL » [ACK] (0x06) 09:35:38.585 DRIVER « [REQ] [SendData] callback id: 230 transmit status: OK 09:35:38.703 SERIAL « 0x01100004001d0a600d01004303012200a053 (18 bytes) 09:35:38.705 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpoint[1]: 16 => 16 [Endpoint 1] 09:35:38.706 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 09:35:38.707 SERIAL » [ACK] (0x06) 09:35:38.708 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 16 °C 09:35:38.715 SERIAL » 0x010900131302750225e741 (11 bytes) 09:35:38.715 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 231 └─[ProtectionCCGet] 09:35:38.717 CNTRLR « [Node 029] received current value of setpoint Heating: 16 °C [Endpoint 1] 09:35:38.717 CNTRLR [Node 029] [~] [Thermostat Setpoint] interviewComplete [Endpoint 1] [internal] : true => true 09:35:38.786 SERIAL « [ACK] (0x06) 09:35:38.795 SERIAL « 0x0104011301e8 (6 bytes) 09:35:38.795 SERIAL » [ACK] (0x06) 09:35:38.799 DRIVER « [RES] [SendData] was sent: true 09:35:38.803 CNTRLR [Node 029] NotificationCC: doing a partial interview... [Endpoint 1] 09:35:38.803 CNTRLR » [Node 029] querying notification status for Power Management... [Endpoint 1] 09:35:38.826 SERIAL « 0x01070013e700000b07 (9 bytes) 09:35:38.826 SERIAL » [ACK] (0x06) 09:35:38.826 DRIVER « [REQ] [SendData] callback id: 231 transmit status: OK 09:35:38.877 SERIAL « 0x010a00040013047503000090 (12 bytes) 09:35:38.878 CNTRLR [Node 019] [~] [Protection] local: 0 => 0 [Endpoint 0] 09:35:38.879 CNTRLR [Node 019] [~] [Protection] rf: 0 => 0 [Endpoint 0] 09:35:38.880 SERIAL » [ACK] (0x06) 09:35:38.881 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 09:35:38.886 SERIAL » 0x011000131d09600d0001710400080025e834 (18 bytes) 09:35:38.886 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 232 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: Power Management 09:35:38.887 CNTRLR « [Node 019] received protection status: local: Unprotected rf Unprotected 09:35:38.887 CNTRLR [Node 019] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 09:35:38.887 CNTRLR [Node 019] FibaroVenetianBlindCC: doing a partial interview... 09:35:38.887 CNTRLR » [Node 019] Requesting venetian blind position and tilt... 09:35:38.891 SERIAL « [ACK] (0x06) 09:35:38.895 SERIAL « 0x0104011301e8 (6 bytes) 09:35:38.895 SERIAL » [ACK] (0x06) 09:35:38.896 DRIVER « [RES] [SendData] was sent: true 09:35:39.009 SERIAL « 0x01070013e800000c0f (9 bytes) 09:35:39.009 SERIAL » [ACK] (0x06) 09:35:39.010 DRIVER « [REQ] [SendData] callback id: 232 transmit status: OK 09:35:39.096 SERIAL « 0x01130004001d0d600d01007105000000ff08fe00e9 (21 bytes) 09:35:39.097 SERIAL » [ACK] (0x06) 09:35:39.098 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 09:35:39.101 SERIAL » 0x010c0013130591010f260225e981 (14 bytes) 09:35:39.101 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 233 └─[FibaroVenetianBlindCCGet] payload: 0x0f2602 09:35:39.102 CNTRLR [Node 029] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 1] 54 09:35:39.103 CNTRLR » [Node 029] querying notification status for System... [Endpoint 1] 09:35:39.106 SERIAL « [ACK] (0x06) 09:35:39.110 SERIAL « 0x0104011301e8 (6 bytes) 09:35:39.110 SERIAL » [ACK] (0x06) 09:35:39.110 DRIVER « [RES] [SendData] was sent: true 09:35:39.216 SERIAL « 0x01070013e900000b09 (9 bytes) 09:35:39.217 SERIAL » [ACK] (0x06) 09:35:39.217 DRIVER « [REQ] [SendData] callback id: 233 transmit status: OK 09:35:39.269 SERIAL « 0x010e000400130891010f260302620034 (16 bytes) 09:35:39.274 CNTRLR [Node 019] [Manufacturer Proprietary] fibaro[venetianBlindsPositi [Endpoint 0] on]: metadata updated 09:35:39.275 CNTRLR [Node 019] [~] [Manufacturer Proprietary] fibaro[venetianBlindsPo [Endpoint 0] sition]: 99 => 98 09:35:39.276 SERIAL » [ACK] (0x06) 09:35:39.277 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[FibaroVenetianBlindCCReport] position: 98 09:35:39.281 SERIAL » 0x011000131d09600d0001710400090025ea37 (18 bytes) 09:35:39.281 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 234 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: System 09:35:39.282 CNTRLR « [Node 019] received venetian blind state: position: 98 tilt: undefined 09:35:39.282 CNTRLR [Node 019] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 09:35:39.283 CNTRLR [Node 019] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 09:35:39.313 SERIAL « [ACK] (0x06) 09:35:39.317 SERIAL « 0x0104011301e8 (6 bytes) 09:35:39.317 SERIAL » [ACK] (0x06) 09:35:39.317 DRIVER « [RES] [SendData] was sent: true 09:35:39.320 CNTRLR [Node 019] Interview stage completed: CommandClasses 09:35:39.320 CNTRLR [Node 019] Interview stage completed: OverwriteConfig 09:35:39.320 CNTRLR » [Node 019] requesting node neighbors... 09:35:39.390 SERIAL « 0x010c00040003063105042205896c (14 bytes) 09:35:39.391 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:35:39.391 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 280 => 141.7 [Endpoint 0] 09:35:39.392 SERIAL » [ACK] (0x06) 09:35:39.393 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 141.7 09:35:39.457 SERIAL « 0x01070013ea00001110 (9 bytes) 09:35:39.457 SERIAL » [ACK] (0x06) 09:35:39.458 DRIVER « [REQ] [SendData] callback id: 234 transmit status: OK 09:35:39.546 SERIAL « 0x01130004001d0d600d01007105000000ff09fe00e8 (21 bytes) 09:35:39.547 SERIAL » [ACK] (0x06) 09:35:39.548 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: System notification status: 255 notification event: Unknown (0xfe) 09:35:39.553 SERIAL » 0x01070080130000006b (9 bytes) 09:35:39.554 DRIVER » [Node 019] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:35:39.555 CNTRLR [Node 029] [~] [Notification] System[unknown]: 254 => 254 [Endpoint 1] 09:35:39.557 CNTRLR [Node 029] [~] [Notification] interviewComplete: true [Endpoint 1] [internal] => true 09:35:39.614 SERIAL « [ACK] (0x06) 09:35:39.619 SERIAL « 0x0120018065fafa670700000000000000000000000000000000000000000000000 (34 bytes) 05b 09:35:39.620 SERIAL » [ACK] (0x06) 09:35:39.621 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 10, 12, 13, 14, 15, 16, 18, 20, 21, 22, 23, 24, 25, 26 , 27, 30, 31, 33, 34, 35 09:35:39.628 SERIAL » 0x010d00131606600d0001750225eb24 (15 bytes) 09:35:39.629 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 235 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 09:35:39.629 CNTRLR « [Node 019] node neighbors received: 1, 3, 6, 7, 10, 12, 13, 14, 15, 16, 18, 20, 21, 22, 23, 24, 25, 26, 27, 30, 31, 33, 34, 35 09:35:39.629 CNTRLR [Node 019] Interview stage completed: Neighbors 09:35:39.630 CNTRLR [Node 019] Interview completed 09:35:39.657 SERIAL « 0x010c00040003063105042205896c (14 bytes) 09:35:39.658 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:35:39.659 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 141.7 => 141.7 [Endpoint 0] 09:35:39.662 SERIAL » [ACK] (0x06) 09:35:39.663 SERIAL « [CAN] (0x18) 09:35:39.665 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 09:35:39.667 CNTRLR [Node 029] ProtectionCC: doing a partial interview... 09:35:39.667 CNTRLR » [Node 029] querying protection status... 09:35:39.672 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 141.7 09:35:39.765 SERIAL » 0x010d00131606600d0001750225eb24 (15 bytes) 09:35:39.766 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 235 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 09:35:39.768 SERIAL « [ACK] (0x06) 09:35:39.775 SERIAL « 0x0104011301e8 (6 bytes) 09:35:39.775 SERIAL » [ACK] (0x06) 09:35:39.776 DRIVER « [RES] [SendData] was sent: true 09:35:41.188 SERIAL « 0x010c0004100306310504220a18e2 (14 bytes) 09:35:41.189 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:35:41.190 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 141.7 => 258.4 [Endpoint 0] 09:35:41.190 SERIAL » [ACK] (0x06) 09:35:41.191 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 258.4 09:35:41.408 SERIAL « 0x010c0004100306310504220a18e2 (14 bytes) 09:35:41.409 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:35:41.409 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 258.4 => 258.4 [Endpoint 0] 09:35:41.410 SERIAL » [ACK] (0x06) 09:35:41.411 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 258.4 09:35:42.337 SERIAL « 0x010c0004100306310504220a18e2 (14 bytes) 09:35:42.339 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:35:42.340 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 258.4 => 258.4 [Endpoint 0] 09:35:42.340 SERIAL » [ACK] (0x06) 09:35:42.342 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 258.4 09:35:42.408 SERIAL « 0x01080004000702840775 (10 bytes) 09:35:42.409 SERIAL » [ACK] (0x06) 09:35:42.411 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:35:42.413 CNTRLR « [Node 007] received wakeup notification 09:35:42.414 CNTRLR [Node 007] The node is awake. 09:35:42.415 CNTRLR [Node 007] The node is ready to be used 09:35:42.420 SERIAL « 0x010c0004000306310504220946af (14 bytes) 09:35:42.421 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:35:42.422 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 258.4 => 237.4 [Endpoint 0] 09:35:42.423 SERIAL » [ACK] (0x06) 09:35:42.425 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 237.4 09:35:42.455 SERIAL « 0x01080004000702840775 (10 bytes) 09:35:42.456 SERIAL » [ACK] (0x06) 09:35:42.457 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:35:42.458 CNTRLR « [Node 007] received wakeup notification 09:35:42.789 SERIAL « 0x01070013eb00011716 (9 bytes) 09:35:42.789 SERIAL » [ACK] (0x06) 09:35:42.790 DRIVER « [REQ] [SendData] callback id: 235 transmit status: OK 09:35:42.793 SERIAL « 0x010d0004001607600d0100750300fd (15 bytes) 09:35:42.795 CNTRLR [Node 022] [~] [Protection] local: 0 => 0 [Endpoint 1] 09:35:42.796 SERIAL » [ACK] (0x06) 09:35:42.797 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ProtectionCCReport] local: Unprotected 09:35:42.802 SERIAL » 0x010d00131d06600d0001750225ec28 (15 bytes) 09:35:42.802 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 236 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 09:35:42.803 CNTRLR « [Node 022] received protection status: local: Unprotected 09:35:42.803 CNTRLR [Node 022] [~] [Protection] interviewComplete: true => [Endpoint 1] [internal] true 09:35:42.848 SERIAL « 0x010c0004000306310504220946af (14 bytes) 09:35:42.849 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:35:42.850 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 237.4 => 237.4 [Endpoint 0] 09:35:42.850 SERIAL » [ACK] (0x06) 09:35:42.851 SERIAL « [CAN] (0x18) 09:35:42.851 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 09:35:42.860 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 237.4 09:35:42.865 CNTRLR [Node 022] BatteryCC: doing a partial interview... [Endpoint 1] 09:35:42.865 CNTRLR » [Node 022] querying battery status... [Endpoint 1] 09:35:42.962 SERIAL » 0x010d00131d06600d0001750225ec28 (15 bytes) 09:35:42.962 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 236 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 09:35:42.966 SERIAL « [ACK] (0x06) 09:35:42.971 SERIAL « 0x0104011301e8 (6 bytes) 09:35:42.971 SERIAL » [ACK] (0x06) 09:35:42.972 DRIVER « [RES] [SendData] was sent: true 09:35:44.365 SERIAL « 0x01070013ec00008c8b (9 bytes) 09:35:44.366 SERIAL » [ACK] (0x06) 09:35:44.367 DRIVER « [REQ] [SendData] callback id: 236 transmit status: OK 09:35:44.522 SERIAL « 0x010d0004001d07600d0100750300f6 (15 bytes) 09:35:44.524 CNTRLR [Node 029] [~] [Protection] local: 0 => 0 [Endpoint 1] 09:35:44.525 SERIAL » [ACK] (0x06) 09:35:44.527 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ProtectionCCReport] local: Unprotected 09:35:44.537 SERIAL » 0x010900131c02600725ed54 (11 bytes) 09:35:44.538 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 237 └─[MultiChannelCCEndPointGet] 09:35:44.539 CNTRLR « [Node 029] received protection status: local: Unprotected 09:35:44.540 CNTRLR [Node 029] [~] [Protection] interviewComplete: true => [Endpoint 1] [internal] true 09:35:44.607 SERIAL « [ACK] (0x06) 09:35:44.609 SERIAL « 0x0104011301e8 (6 bytes) 09:35:44.610 SERIAL » [ACK] (0x06) 09:35:44.611 DRIVER « [RES] [SendData] was sent: true 09:35:44.614 CNTRLR [Node 029] BatteryCC: doing a partial interview... [Endpoint 1] 09:35:44.614 CNTRLR » [Node 029] querying battery status... [Endpoint 1] 09:35:45.971 SERIAL « 0x01070013ed00008f89 (9 bytes) 09:35:45.971 SERIAL » [ACK] (0x06) 09:35:45.972 DRIVER « [REQ] [SendData] callback id: 237 transmit status: OK 09:35:46.055 SERIAL « 0x010b0004001c05600800020083 (13 bytes) 09:35:46.057 CNTRLR [Node 028] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:35:46.058 CNTRLR [Node 028] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 09:35:46.058 CNTRLR [Node 028] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:35:46.059 CNTRLR [Node 028] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 09:35:46.059 SERIAL » [ACK] (0x06) 09:35:46.060 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:35:46.067 SERIAL » 0x010d00131d06600d0001800225eedf (15 bytes) 09:35:46.068 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 238 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BatteryCCGet] 09:35:46.068 CNTRLR [Node 028] The node is alive. 09:35:46.070 CNTRLR [Node 028] The node is ready to be used 09:35:46.072 CNTRLR « [Node 028] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:35:46.073 CNTRLR » [Node 028] querying all endpoints... 09:35:46.080 SERIAL « [ACK] (0x06) 09:35:46.082 SERIAL « 0x0104011301e8 (6 bytes) 09:35:46.083 SERIAL » [ACK] (0x06) 09:35:46.087 DRIVER « [RES] [SendData] was sent: true 09:35:47.506 SERIAL « 0x01070013ee00008f8a (9 bytes) 09:35:47.506 SERIAL » [ACK] (0x06) 09:35:47.507 DRIVER « [REQ] [SendData] callback id: 238 transmit status: OK 09:35:47.622 SERIAL « 0x010d0004001d07600d010080036360 (15 bytes) 09:35:47.623 CNTRLR [Node 029] [~] [Battery] level: 99 => 99 [Endpoint 1] 09:35:47.624 CNTRLR [Node 029] [~] [Battery] isLow: false => false [Endpoint 1] 09:35:47.624 SERIAL » [ACK] (0x06) 09:35:47.626 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BatteryCCReport] level: 99 is low: false 09:35:47.629 SERIAL » 0x010900131202600725ef58 (11 bytes) 09:35:47.629 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 239 └─[MultiChannelCCEndPointGet] 09:35:47.630 CNTRLR « [Node 029] received response for battery information: [Endpoint 1] level: 99 09:35:47.630 CNTRLR [Node 029] [~] [Battery] interviewComplete: true => tr [Endpoint 1] [internal] ue 09:35:47.693 SERIAL « [ACK] (0x06) 09:35:47.699 SERIAL « 0x0104011301e8 (6 bytes) 09:35:47.700 SERIAL » [ACK] (0x06) 09:35:47.703 DRIVER « [RES] [SendData] was sent: true 09:35:47.709 CNTRLR [Node 029] ClockCC: doing a partial interview... 09:35:47.709 CNTRLR » [Node 029] requesting current clock setting... 09:35:47.715 SERIAL « 0x01070013ef00000703 (9 bytes) 09:35:47.716 SERIAL » [ACK] (0x06) 09:35:47.717 DRIVER « [REQ] [SendData] callback id: 239 transmit status: OK 09:35:47.788 SERIAL « 0x010b000400120560080002008d (13 bytes) 09:35:47.789 CNTRLR [Node 018] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:35:47.789 CNTRLR [Node 018] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 09:35:47.789 CNTRLR [Node 018] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:35:47.789 CNTRLR [Node 018] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 09:35:47.789 SERIAL » [ACK] (0x06) 09:35:47.790 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:35:47.793 SERIAL » 0x010d00131d06600d0001810525f0c7 (15 bytes) 09:35:47.794 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 240 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ClockCCGet] 09:35:47.794 CNTRLR « [Node 018] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:35:47.794 CNTRLR » [Node 018] querying all endpoints... 09:35:47.797 SERIAL « [ACK] (0x06) 09:35:47.802 SERIAL « 0x0104011301e8 (6 bytes) 09:35:47.802 SERIAL » [ACK] (0x06) 09:35:47.802 DRIVER « [RES] [SendData] was sent: true 09:35:47.916 SERIAL « 0x01070013f000000c17 (9 bytes) 09:35:47.917 SERIAL » [ACK] (0x06) 09:35:47.917 DRIVER « [REQ] [SendData] callback id: 240 transmit status: OK 09:35:48.003 SERIAL « 0x010e0004001d08600d01008106e924c6 (16 bytes) 09:35:48.004 SERIAL » [ACK] (0x06) 09:35:48.005 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ClockCCReport] clock setting: Sunday, 09:36 09:35:48.019 SERIAL » 0x010900131802250225f10c (11 bytes) 09:35:48.020 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 241 └─[BinarySwitchCCGet] 09:35:48.021 CNTRLR « [Node 029] received current clock setting: Sunday, 09:36 09:35:48.021 CNTRLR [Node 029] [~] [Clock] interviewComplete: true => true [Endpoint 1] [internal] 09:35:48.055 SERIAL « [ACK] (0x06) 09:35:48.060 SERIAL « 0x0104011301e8 (6 bytes) 09:35:48.061 SERIAL » [ACK] (0x06) 09:35:48.062 DRIVER « [RES] [SendData] was sent: true 09:35:48.066 CNTRLR [Node 029] ZWavePlusCC: doing a partial interview... [Endpoint 2] 09:35:48.066 CNTRLR [Node 029] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 09:35:48.067 CNTRLR [Node 029] MultilevelSensorCC: doing a partial interview... [Endpoint 2] 09:35:48.068 CNTRLR » [Node 029] querying Air temperature sensor reading... [Endpoint 2] 09:35:48.100 SERIAL « 0x01070013f100000812 (9 bytes) 09:35:48.100 SERIAL » [ACK] (0x06) 09:35:48.101 DRIVER « [REQ] [SendData] callback id: 241 transmit status: OK 09:35:48.113 SERIAL « 0x01090004001803250300cf (11 bytes) 09:35:48.114 CNTRLR [Node 024] [~] [Binary Switch] currentValue: false => false [Endpoint 0] 09:35:48.114 SERIAL » [ACK] (0x06) 09:35:48.115 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 09:35:48.119 SERIAL » 0x010f00131d08600d00023104010025f27a (17 bytes) 09:35:48.120 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 242 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:35:48.120 CNTRLR « [Node 024] received Binary Switch state: current value: false 09:35:48.121 CNTRLR [Node 024] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 09:35:48.122 CNTRLR [Node 024] MeterCC: doing a partial interview... 09:35:48.122 CNTRLR » [Node 024] querying meter value (type = Electric, scale = kWh)... 09:35:48.126 SERIAL « [ACK] (0x06) 09:35:48.128 SERIAL « 0x0104011301e8 (6 bytes) 09:35:48.129 SERIAL » [ACK] (0x06) 09:35:48.129 DRIVER « [RES] [SendData] was sent: true 09:35:48.187 SERIAL « 0x01070013f20000061f (9 bytes) 09:35:48.188 SERIAL » [ACK] (0x06) 09:35:48.188 DRIVER « [REQ] [SendData] callback id: 242 transmit status: OK 09:35:48.274 SERIAL « 0x01100004001d0a600d02003105012200b733 (18 bytes) 09:35:48.275 CNTRLR [Node 029] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:35:48.276 CNTRLR [Node 029] [~] [Multilevel Sensor] Air temperature: 18.2 => 18.3 [Endpoint 2] 09:35:48.276 SERIAL » [ACK] (0x06) 09:35:48.278 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.3 09:35:48.281 SERIAL » 0x010a00131a0370050c25f350 (12 bytes) 09:35:48.281 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 243 └─[ConfigurationCCGet] parameter #: 12 09:35:48.282 CNTRLR « [Node 029] received current Air temperature sensor reading: 18.3 [Endpoint 2] °C 09:35:48.282 CNTRLR [Node 029] [~] [Multilevel Sensor] interviewComplete: [Endpoint 2] [internal] true => true 09:35:48.283 CNTRLR [Node 029] NotificationCC: doing a partial interview... [Endpoint 2] 09:35:48.283 CNTRLR » [Node 029] querying notification status for Power Management... [Endpoint 2] 09:35:48.286 SERIAL « [ACK] (0x06) 09:35:48.289 SERIAL « 0x0104011301e8 (6 bytes) 09:35:48.290 SERIAL » [ACK] (0x06) 09:35:48.290 DRIVER « [RES] [SendData] was sent: true 09:35:48.367 SERIAL « 0x01070013f300000810 (9 bytes) 09:35:48.367 SERIAL » [ACK] (0x06) 09:35:48.368 DRIVER « [REQ] [SendData] callback id: 243 transmit status: OK 09:35:48.377 SERIAL « 0x010c0004001a0670060c02009605 (14 bytes) 09:35:48.383 CNTRLR [Node 026] [~] [Configuration] 12: 150 => 150 09:35:48.384 SERIAL » [ACK] (0x06) 09:35:48.385 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 150 09:35:48.388 SERIAL » 0x011000131d09600d0002710400080025f42b (18 bytes) 09:35:48.388 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 244 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: Power Management 09:35:48.389 CNTRLR « [Node 026] parameter #12 has value: 150 09:35:48.389 CNTRLR » [Node 026] querying parameter #13 value... 09:35:48.392 SERIAL « [ACK] (0x06) 09:35:48.397 SERIAL « 0x0104011301e8 (6 bytes) 09:35:48.398 SERIAL » [ACK] (0x06) 09:35:48.398 DRIVER « [RES] [SendData] was sent: true 09:35:48.459 SERIAL « 0x01070013f400000619 (9 bytes) 09:35:48.460 SERIAL » [ACK] (0x06) 09:35:48.460 DRIVER « [REQ] [SendData] callback id: 244 transmit status: OK 09:35:48.546 SERIAL « 0x01130004001d0d600d02007105000000ff08fe00ea (21 bytes) 09:35:48.547 SERIAL » [ACK] (0x06) 09:35:48.547 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 09:35:48.552 SERIAL » 0x010900130602984025f5e9 (11 bytes) 09:35:48.553 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 245 └─[SecurityCCNonceGet] 09:35:48.554 CNTRLR [Node 029] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 2] 54 09:35:48.555 CNTRLR » [Node 029] querying notification status for System... [Endpoint 2] 09:35:48.559 SERIAL « [ACK] (0x06) 09:35:48.561 SERIAL « 0x0104011301e8 (6 bytes) 09:35:48.561 SERIAL » [ACK] (0x06) 09:35:48.562 DRIVER « [RES] [SendData] was sent: true 09:35:49.884 SERIAL « 0x01070013f50000859b (9 bytes) 09:35:49.885 SERIAL » [ACK] (0x06) 09:35:49.886 DRIVER « [REQ] [SendData] callback id: 245 transmit status: OK 09:35:49.907 SERIAL « 0x0110000400060a9880224af802064aaa35be (18 bytes) 09:35:49.908 SERIAL » [ACK] (0x06) 09:35:49.909 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x224af802064aaa35 09:35:49.916 SERIAL » 0x01240013061d988140045f4d63539951a577eb6c6daae52c0fc222f23796c76ef (38 bytes) ade7c25f6a1 09:35:49.917 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 246 └─[SecurityCCCommandEncapsulation] │ nonce id: 34 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: Power Management 09:35:49.921 SERIAL « [ACK] (0x06) 09:35:49.928 SERIAL « 0x0104011301e8 (6 bytes) 09:35:49.929 SERIAL » [ACK] (0x06) 09:35:49.929 DRIVER « [RES] [SendData] was sent: true 09:35:49.953 SERIAL « 0x01070013f60000031e (9 bytes) 09:35:49.954 SERIAL » [ACK] (0x06) 09:35:49.955 DRIVER « [REQ] [SendData] callback id: 246 transmit status: OK 09:35:49.976 SERIAL « 0x0108000400060298402f (10 bytes) 09:35:49.977 SERIAL » [ACK] (0x06) 09:35:49.978 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:35:49.987 SERIAL » 0x01110013060a988095040ad5596389a2240092 (19 bytes) 09:35:49.988 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x95040ad5596389a2 09:35:49.990 SERIAL « [ACK] (0x06) 09:35:49.997 SERIAL « 0x0104011301e8 (6 bytes) 09:35:49.997 SERIAL » [ACK] (0x06) 09:35:49.998 DRIVER « [RES] [SendData] was sent: true 09:35:50.041 SERIAL « 0x012700040006219881571c30cd9dad1803a39a6c24a1b127cf694802a60e0a95e (41 bytes) 61f581487fbdfd521 09:35:50.043 SERIAL » [ACK] (0x06) 09:35:50.044 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 09:35:50.048 SERIAL » 0x011000131d09600d0002710400090025f729 (18 bytes) 09:35:50.049 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 247 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:35:50.050 CNTRLR [Node 006] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 1] 54 09:35:50.051 CNTRLR » [Node 006] querying notification status for System... [Endpoint 1] 09:35:50.055 SERIAL « [ACK] (0x06) 09:35:50.058 SERIAL « 0x0104011301e8 (6 bytes) 09:35:50.058 SERIAL » [ACK] (0x06) 09:35:50.060 DRIVER « [RES] [SendData] was sent: true 09:35:50.116 SERIAL « 0x01070013f70000061a (9 bytes) 09:35:50.117 SERIAL » [ACK] (0x06) 09:35:50.117 DRIVER « [REQ] [SendData] callback id: 247 transmit status: OK 09:35:50.289 SERIAL « 0x010c0004000306310504220406e2 (14 bytes) 09:35:50.292 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:35:50.293 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 237.4 => 103 [Endpoint 0] 09:35:50.295 SERIAL » [ACK] (0x06) 09:35:50.298 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 103 09:35:51.721 CNTRLR [Node 029] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:35:52.224 SERIAL » 0x011000131d09600d0002710400090025f729 (18 bytes) 09:35:52.225 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 247 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:35:52.226 SERIAL « [ACK] (0x06) 09:35:52.233 SERIAL « 0x0104011301e8 (6 bytes) 09:35:52.233 SERIAL » [ACK] (0x06) 09:35:52.234 DRIVER « [RES] [SendData] was sent: true 09:35:52.289 SERIAL « 0x010c0004000306310504220a769c (14 bytes) 09:35:52.291 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:35:52.292 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 103 => 267.8 [Endpoint 0] 09:35:52.293 SERIAL » [ACK] (0x06) 09:35:52.295 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 267.8 09:35:52.414 DRIVER The awake timeout for node 7 has elapsed. Assuming it is asleep. 09:35:52.415 CNTRLR [Node 007] The node is now asleep. 09:35:53.689 SERIAL « 0x01070013f70000928e (9 bytes) 09:35:53.689 SERIAL » [ACK] (0x06) 09:35:53.690 DRIVER « [REQ] [SendData] callback id: 247 transmit status: OK 09:35:55.292 CNTRLR [Node 029] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:35:55.795 SERIAL » 0x011000131d09600d0002710400090025f729 (18 bytes) 09:35:55.795 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 247 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:35:55.797 SERIAL « [ACK] (0x06) 09:35:55.804 SERIAL « 0x0104011301e8 (6 bytes) 09:35:55.804 SERIAL » [ACK] (0x06) 09:35:55.804 DRIVER « [RES] [SendData] was sent: true 09:35:57.219 SERIAL « 0x01070013f700008e92 (9 bytes) 09:35:57.219 SERIAL » [ACK] (0x06) 09:35:57.220 DRIVER « [REQ] [SendData] callback id: 247 transmit status: OK 09:35:58.829 SERIAL » 0x010d00131606600d0001800225f8c2 (15 bytes) 09:35:58.830 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 248 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BatteryCCGet] 09:35:58.831 CNTRLR [Node 029] Interview attempt 1/5 failed, retrying in 5000 ms... 09:35:58.833 SERIAL « [ACK] (0x06) 09:35:58.839 SERIAL « 0x0104011301e8 (6 bytes) 09:35:58.839 SERIAL » [ACK] (0x06) 09:35:58.840 DRIVER « [RES] [SendData] was sent: true 09:36:00.215 SERIAL « 0x01070013f800008a99 (9 bytes) 09:36:00.215 SERIAL » [ACK] (0x06) 09:36:00.216 DRIVER « [REQ] [SendData] callback id: 248 transmit status: OK 09:36:00.330 SERIAL « 0x010d0004001607600d01008003636b (15 bytes) 09:36:00.331 CNTRLR [Node 022] [~] [Battery] level: 99 => 99 [Endpoint 1] 09:36:00.332 CNTRLR [Node 022] [~] [Battery] isLow: false => false [Endpoint 1] 09:36:00.333 SERIAL » [ACK] (0x06) 09:36:00.334 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BatteryCCReport] level: 99 is low: false 09:36:00.338 SERIAL » 0x010b00131c04600bffff25f948 (13 bytes) 09:36:00.339 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 249 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:36:00.339 CNTRLR « [Node 022] received response for battery information: [Endpoint 1] level: 99 09:36:00.340 CNTRLR [Node 022] [~] [Battery] interviewComplete: true => tr [Endpoint 1] [internal] ue 09:36:00.382 SERIAL « [ACK] (0x06) 09:36:00.387 SERIAL « 0x0104011301e8 (6 bytes) 09:36:00.388 SERIAL » [ACK] (0x06) 09:36:00.389 DRIVER « [RES] [SendData] was sent: true 09:36:00.396 CNTRLR [Node 022] ClockCC: doing a partial interview... 09:36:00.396 CNTRLR » [Node 022] requesting current clock setting... 09:36:01.772 SERIAL « 0x01070013f900008f9d (9 bytes) 09:36:01.773 SERIAL » [ACK] (0x06) 09:36:01.773 DRIVER « [REQ] [SendData] callback id: 249 transmit status: OK 09:36:01.853 SERIAL « 0x010d0004001c07600c00ffff010282 (15 bytes) 09:36:01.853 SERIAL » [ACK] (0x06) 09:36:01.854 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 09:36:01.857 SERIAL » 0x010b00131204600bffff25fa45 (13 bytes) 09:36:01.858 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 250 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:36:01.858 CNTRLR « [Node 028] received endpoints: 1, 2 09:36:01.858 CNTRLR » [Node 028] querying capabilities for endpoint #1... 09:36:01.861 SERIAL « [ACK] (0x06) 09:36:01.866 SERIAL « 0x0104011301e8 (6 bytes) 09:36:01.866 SERIAL » [ACK] (0x06) 09:36:01.866 DRIVER « [RES] [SendData] was sent: true 09:36:01.978 SERIAL « 0x01070013fa00000b1a (9 bytes) 09:36:01.979 SERIAL » [ACK] (0x06) 09:36:01.979 DRIVER « [REQ] [SendData] callback id: 250 transmit status: OK 09:36:02.059 SERIAL « 0x010d0004001207600c00ffff01028c (15 bytes) 09:36:02.059 SERIAL » [ACK] (0x06) 09:36:02.060 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 09:36:02.063 SERIAL » 0x010a0013180332010025fb10 (12 bytes) 09:36:02.064 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 251 └─[MeterCCGet] duration: kWh 09:36:02.064 CNTRLR « [Node 018] received endpoints: 1, 2 09:36:02.064 CNTRLR » [Node 018] querying capabilities for endpoint #1... 09:36:02.067 SERIAL « [ACK] (0x06) 09:36:02.072 SERIAL « 0x0104011301e8 (6 bytes) 09:36:02.072 SERIAL » [ACK] (0x06) 09:36:02.072 DRIVER « [RES] [SendData] was sent: true 09:36:02.150 SERIAL « 0x01070013fb00000919 (9 bytes) 09:36:02.150 SERIAL » [ACK] (0x06) 09:36:02.151 DRIVER « [REQ] [SendData] callback id: 251 transmit status: OK 09:36:02.165 SERIAL « 0x0110000400180a32022144000001bf000012 (18 bytes) 09:36:02.166 CNTRLR [Node 024] [~] [Meter] value[65537]: 4.47 => 4.47 [Endpoint 0] 09:36:02.167 CNTRLR [Node 024] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 09:36:02.167 SERIAL » [ACK] (0x06) 09:36:02.168 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 4.47 time delta: 0 seconds 09:36:02.171 SERIAL » 0x010a00131a0370050d25fc5e (12 bytes) 09:36:02.171 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 252 └─[ConfigurationCCGet] parameter #: 13 09:36:02.171 CNTRLR » [Node 024] querying meter value (type = Electric, scale = W)... 09:36:02.177 SERIAL « [ACK] (0x06) 09:36:02.179 SERIAL « 0x0104011301e8 (6 bytes) 09:36:02.179 SERIAL » [ACK] (0x06) 09:36:02.180 DRIVER « [RES] [SendData] was sent: true 09:36:02.197 SERIAL « 0x01070013fc00000215 (9 bytes) 09:36:02.197 SERIAL » [ACK] (0x06) 09:36:02.197 DRIVER « [REQ] [SendData] callback id: 252 transmit status: OK 09:36:02.207 SERIAL « 0x010b0004001a0570060d010194 (13 bytes) 09:36:02.213 CNTRLR [Node 026] [~] [Configuration] 13: 1 => 1 09:36:02.214 SERIAL » [ACK] (0x06) 09:36:02.215 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 1 09:36:02.220 SERIAL » 0x010900130602984025fde1 (11 bytes) 09:36:02.220 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 253 └─[SecurityCCNonceGet] 09:36:02.220 CNTRLR « [Node 026] parameter #13 has value: 1 09:36:02.220 CNTRLR » [Node 026] querying parameter #14 value... 09:36:02.225 SERIAL « [ACK] (0x06) 09:36:02.228 SERIAL « 0x0104011301e8 (6 bytes) 09:36:02.229 SERIAL » [ACK] (0x06) 09:36:02.229 DRIVER « [RES] [SendData] was sent: true 09:36:03.479 SERIAL « 0x01070013fd00007d6b (9 bytes) 09:36:03.479 SERIAL » [ACK] (0x06) 09:36:03.481 DRIVER « [REQ] [SendData] callback id: 253 transmit status: OK 09:36:03.501 SERIAL « 0x0110000400060a988056ce801a34cc5192c6 (18 bytes) 09:36:03.502 SERIAL » [ACK] (0x06) 09:36:03.503 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x56ce801a34cc5192 09:36:03.510 SERIAL » 0x01240013061d98812a3bdc370f26ba090096cdba53830a1af30a56d1aad842b7c (38 bytes) 7e40025fe8a 09:36:03.511 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 254 └─[SecurityCCCommandEncapsulation] │ nonce id: 86 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: System 09:36:03.515 SERIAL « [ACK] (0x06) 09:36:03.522 SERIAL « 0x0104011301e8 (6 bytes) 09:36:03.522 SERIAL » [ACK] (0x06) 09:36:03.523 DRIVER « [RES] [SendData] was sent: true 09:36:03.548 SERIAL « 0x01070013fe00000316 (9 bytes) 09:36:03.548 SERIAL » [ACK] (0x06) 09:36:03.549 DRIVER « [REQ] [SendData] callback id: 254 transmit status: OK 09:36:03.570 SERIAL « 0x0108000400060298402f (10 bytes) 09:36:03.571 SERIAL » [ACK] (0x06) 09:36:03.572 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:36:03.580 SERIAL » 0x01110013060a9880c9fe88d8411715402400a9 (19 bytes) 09:36:03.581 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xc9fe88d841171540 09:36:03.583 SERIAL « [ACK] (0x06) 09:36:03.589 SERIAL « 0x0104011301e8 (6 bytes) 09:36:03.590 SERIAL » [ACK] (0x06) 09:36:03.591 DRIVER « [RES] [SendData] was sent: true 09:36:03.634 SERIAL « 0x012700040006219881fa35cd10f0d03c6912316ca14648c8b38a9b4b9fb087c9a (41 bytes) e078b8801fe4f3f00 09:36:03.635 SERIAL » [ACK] (0x06) 09:36:03.637 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: System notification status: 255 notification event: Unknown (0xfe) 09:36:03.643 SERIAL » 0x010d00131606600d0001810525ffc3 (15 bytes) 09:36:03.644 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 255 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ClockCCGet] 09:36:03.645 CNTRLR [Node 006] [~] [Notification] System[unknown]: 254 => 254 [Endpoint 1] 09:36:03.646 CNTRLR [Node 006] [~] [Notification] interviewComplete: true [Endpoint 1] [internal] => true 09:36:03.694 SERIAL « [ACK] (0x06) 09:36:03.699 SERIAL « 0x0104011301e8 (6 bytes) 09:36:03.700 SERIAL » [ACK] (0x06) 09:36:03.702 DRIVER « [RES] [SendData] was sent: true 09:36:03.705 CNTRLR [Node 006] ProtectionCC: doing a partial interview... 09:36:03.705 CNTRLR » [Node 006] querying protection status... 09:36:03.832 CNTRLR [Node 029] Beginning interview - last completed stage: RestartFromCache 09:36:03.832 CNTRLR » [Node 029] pinging the node... 09:36:05.046 SERIAL « 0x01070013ff00008c98 (9 bytes) 09:36:05.046 SERIAL » [ACK] (0x06) 09:36:05.046 DRIVER « [REQ] [SendData] callback id: 255 transmit status: OK 09:36:05.163 SERIAL « 0x010e0004001608600d01008106e91cf5 (16 bytes) 09:36:05.163 SERIAL » [ACK] (0x06) 09:36:05.164 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ClockCCReport] clock setting: Sunday, 09:28 09:36:05.167 SERIAL » 0x010800131d01002501dc (10 bytes) 09:36:05.168 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 1 └─[NoOperationCC] 09:36:05.168 CNTRLR « [Node 022] received current clock setting: Sunday, 09:28 09:36:05.170 CNTRLR [Node 022] [~] [Clock] interviewComplete: true => true [Endpoint 1] [internal] 09:36:05.200 SERIAL « [ACK] (0x06) 09:36:05.203 SERIAL « 0x0104011301e8 (6 bytes) 09:36:05.204 SERIAL » [ACK] (0x06) 09:36:05.204 DRIVER « [RES] [SendData] was sent: true 09:36:05.208 CNTRLR [Node 022] ZWavePlusCC: doing a partial interview... [Endpoint 2] 09:36:05.209 CNTRLR [Node 022] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 09:36:05.209 CNTRLR [Node 022] MultilevelSensorCC: doing a partial interview... [Endpoint 2] 09:36:05.209 CNTRLR » [Node 022] querying Air temperature sensor reading... [Endpoint 2] 09:36:06.627 SERIAL « 0x01070013010000917b (9 bytes) 09:36:06.628 SERIAL » [ACK] (0x06) 09:36:06.629 DRIVER « [REQ] [SendData] callback id: 1 transmit status: OK 09:36:06.637 SERIAL » 0x010a00131c036009012502b6 (12 bytes) 09:36:06.638 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 2 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:36:06.639 CNTRLR « [Node 029] ping successful 09:36:06.644 CNTRLR [Node 029] ManufacturerSpecificCC: doing a partial interview... 09:36:06.645 CNTRLR [Node 029] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:36:06.719 SERIAL « [ACK] (0x06) 09:36:06.721 SERIAL « 0x0104011301e8 (6 bytes) 09:36:06.721 SERIAL » [ACK] (0x06) 09:36:06.729 DRIVER « [RES] [SendData] was sent: true 09:36:06.733 CNTRLR [Node 029] VersionCC: doing a partial interview... 09:36:06.733 CNTRLR [Node 029] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:36:06.733 CNTRLR [Node 029] trying to load device config 09:36:06.737 CNTRLR [Node 029] device config loaded 09:36:06.737 CNTRLR [Node 029] ZWavePlusCC: doing a partial interview... 09:36:06.737 CNTRLR [Node 029] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:36:06.738 CNTRLR » [Node 029] querying device endpoint information... 09:36:08.001 SERIAL « 0x010700130200008861 (9 bytes) 09:36:08.002 SERIAL » [ACK] (0x06) 09:36:08.002 DRIVER « [REQ] [SendData] callback id: 2 transmit status: OK 09:36:08.092 SERIAL « 0x011a0004001c14600a0108065e8e404353989f596c7175808185229c (28 bytes) 09:36:08.093 CNTRLR [Node 028] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 1] [internal] 64,67,83,152,159,89,108,113,117,128,129,133,34 => 94,142,64,67,83,152,159,89,1 08,113,117,128,129,133,34 09:36:08.093 SERIAL » [ACK] (0x06) 09:36:08.094 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:36:08.097 SERIAL » 0x010900131d0260072503bb (11 bytes) 09:36:08.097 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 3 └─[MultiChannelCCEndPointGet] 09:36:08.098 CNTRLR « [Node 028] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:36:08.098 CNTRLR » [Node 028] querying capabilities for endpoint #2... 09:36:08.100 SERIAL « [ACK] (0x06) 09:36:08.105 SERIAL « 0x0104011301e8 (6 bytes) 09:36:08.105 SERIAL » [ACK] (0x06) 09:36:08.106 DRIVER « [RES] [SendData] was sent: true 09:36:09.545 SERIAL « 0x010700130300009078 (9 bytes) 09:36:09.546 SERIAL » [ACK] (0x06) 09:36:09.546 DRIVER « [REQ] [SendData] callback id: 3 transmit status: OK 09:36:09.633 SERIAL « 0x010b0004001d05600800020082 (13 bytes) 09:36:09.634 CNTRLR [Node 029] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:36:09.635 CNTRLR [Node 029] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 09:36:09.635 CNTRLR [Node 029] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:36:09.636 CNTRLR [Node 029] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 09:36:09.636 SERIAL » [ACK] (0x06) 09:36:09.637 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:36:09.643 SERIAL » 0x010a001312036009012504be (12 bytes) 09:36:09.644 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 4 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:36:09.645 CNTRLR « [Node 029] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:36:09.646 CNTRLR » [Node 029] querying all endpoints... 09:36:09.651 SERIAL « [ACK] (0x06) 09:36:09.653 SERIAL « 0x0104011301e8 (6 bytes) 09:36:09.654 SERIAL » [ACK] (0x06) 09:36:09.655 DRIVER « [RES] [SendData] was sent: true 09:36:09.759 SERIAL « 0x010700130400000be4 (9 bytes) 09:36:09.760 SERIAL » [ACK] (0x06) 09:36:09.760 DRIVER « [REQ] [SendData] callback id: 4 transmit status: OK 09:36:09.846 SERIAL « 0x011a0004001214600a0108065e8e404353989f596c71758081852292 (28 bytes) 09:36:09.847 CNTRLR [Node 018] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 1] [internal] 64,67,83,152,159,89,108,113,117,128,129,133,34 => 94,142,64,67,83,152,159,89,1 08,113,117,128,129,133,34 09:36:09.847 SERIAL » [ACK] (0x06) 09:36:09.849 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:36:09.855 SERIAL » 0x010b00131d04600bffff2505b5 (13 bytes) 09:36:09.856 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 5 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:36:09.857 CNTRLR « [Node 018] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:36:09.857 CNTRLR » [Node 018] querying capabilities for endpoint #2... 09:36:09.862 SERIAL « [ACK] (0x06) 09:36:09.865 SERIAL « 0x0104011301e8 (6 bytes) 09:36:09.865 SERIAL » [ACK] (0x06) 09:36:09.866 DRIVER « [RES] [SendData] was sent: true 09:36:11.248 SERIAL « 0x010700130500008b65 (9 bytes) 09:36:11.249 SERIAL » [ACK] (0x06) 09:36:11.250 DRIVER « [REQ] [SendData] callback id: 5 transmit status: OK 09:36:11.292 SERIAL « 0x010c000400030631050422057e9b (14 bytes) 09:36:11.293 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:11.295 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 267.8 => 140.6 [Endpoint 0] 09:36:11.296 SERIAL » [ACK] (0x06) 09:36:11.297 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 140.6 09:36:11.333 SERIAL « 0x010d0004001d07600c00ffff010283 (15 bytes) 09:36:11.334 SERIAL » [ACK] (0x06) 09:36:11.336 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 09:36:11.341 SERIAL » 0x010a001318033201102506fd (12 bytes) 09:36:11.342 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 6 └─[MeterCCGet] duration: W 09:36:11.343 CNTRLR « [Node 029] received endpoints: 1, 2 09:36:11.343 CNTRLR » [Node 029] querying capabilities for endpoint #1... 09:36:11.348 SERIAL « [ACK] (0x06) 09:36:11.350 SERIAL « 0x0104011301e8 (6 bytes) 09:36:11.351 SERIAL » [ACK] (0x06) 09:36:11.352 DRIVER « [RES] [SendData] was sent: true 09:36:11.430 SERIAL « 0x0107001306000009e4 (9 bytes) 09:36:11.431 SERIAL » [ACK] (0x06) 09:36:11.432 DRIVER « [REQ] [SendData] callback id: 6 transmit status: OK 09:36:11.445 SERIAL « 0x010e00040018083202213200000000c6 (16 bytes) 09:36:11.446 CNTRLR [Node 024] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 09:36:11.447 CNTRLR [Node 024] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 09:36:11.447 SERIAL » [ACK] (0x06) 09:36:11.448 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 09:36:11.459 SERIAL » 0x010a00131d036009012507b2 (12 bytes) 09:36:11.460 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 7 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:36:11.461 CNTRLR [Node 024] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 09:36:11.515 SERIAL « [ACK] (0x06) 09:36:11.519 SERIAL « 0x0104011301e8 (6 bytes) 09:36:11.519 SERIAL » [ACK] (0x06) 09:36:11.520 DRIVER « [RES] [SendData] was sent: true 09:36:11.525 CNTRLR [Node 024] ConfigurationCC: Loading configuration parameters from device confi g 09:36:11.531 CNTRLR [Node 024] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:36:11.532 CNTRLR [Node 024] [Configuration] 9: metadata updated 09:36:11.534 CNTRLR [Node 024] [Configuration] 10: metadata updated 09:36:11.535 CNTRLR [Node 024] [Configuration] 11: metadata updated 09:36:11.537 CNTRLR [Node 024] [Configuration] 12: metadata updated 09:36:11.539 CNTRLR [Node 024] [Configuration] 13: metadata updated 09:36:11.541 CNTRLR [Node 024] [Configuration] 15: metadata updated 09:36:11.543 CNTRLR [Node 024] [Configuration] 16: metadata updated 09:36:11.544 CNTRLR [Node 024] [Configuration] 17: metadata updated 09:36:11.546 CNTRLR [Node 024] [Configuration] 18: metadata updated 09:36:11.548 CNTRLR [Node 024] [Configuration] 20: metadata updated 09:36:11.550 CNTRLR [Node 024] [Configuration] 21: metadata updated 09:36:11.551 CNTRLR [Node 024] [Configuration] 27: metadata updated 09:36:11.553 CNTRLR [Node 024] [Configuration] 28: metadata updated 09:36:11.555 CNTRLR [Node 024] [Configuration] 29: metadata updated 09:36:11.557 CNTRLR [Node 024] [Configuration] 30: metadata updated 09:36:11.558 CNTRLR [Node 024] [Configuration] 31: metadata updated 09:36:11.560 CNTRLR [Node 024] [Configuration] 32: metadata updated 09:36:11.562 CNTRLR [Node 024] [Configuration] 33: metadata updated 09:36:11.563 CNTRLR [Node 024] [Configuration] 35: metadata updated 09:36:11.565 CNTRLR [Node 024] [Configuration] 36: metadata updated 09:36:11.567 CNTRLR [Node 024] [Configuration] 37: metadata updated 09:36:11.568 CNTRLR [Node 024] [Configuration] 38: metadata updated 09:36:11.570 CNTRLR [Node 024] [Configuration] 40: metadata updated 09:36:11.572 CNTRLR [Node 024] [Configuration] 41: metadata updated 09:36:11.574 CNTRLR [Node 024] [Configuration] 42: metadata updated 09:36:11.575 CNTRLR [Node 024] [Configuration] 43: metadata updated 09:36:11.577 CNTRLR [Node 024] [Configuration] 44: metadata updated 09:36:11.579 CNTRLR [Node 024] [Configuration] 50: metadata updated 09:36:11.580 CNTRLR [Node 024] [Configuration] 51: metadata updated 09:36:11.582 CNTRLR [Node 024] [Configuration] 53: metadata updated 09:36:11.584 CNTRLR [Node 024] [Configuration] 54: metadata updated 09:36:11.585 CNTRLR [Node 024] [Configuration] 55: metadata updated 09:36:11.587 CNTRLR [Node 024] [Configuration] 57: metadata updated 09:36:11.589 CNTRLR [Node 024] [Configuration] 58: metadata updated 09:36:11.591 CNTRLR [Node 024] [Configuration] 59: metadata updated 09:36:11.592 CNTRLR [Node 024] [Configuration] 60: metadata updated 09:36:11.597 CNTRLR [Node 024] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:36:11.598 CNTRLR » [Node 024] querying parameter #9 value... 09:36:11.604 SERIAL « 0x0107001307000006ea (9 bytes) 09:36:11.605 SERIAL » [ACK] (0x06) 09:36:11.606 DRIVER « [REQ] [SendData] callback id: 7 transmit status: OK 09:36:11.625 SERIAL « 0x011a0004001d14600a0108065e8e404353989f596c7175808185229d (28 bytes) 09:36:11.626 CNTRLR [Node 029] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 1] [internal] 64,67,83,152,159,89,108,113,117,128,129,133,34 => 94,142,64,67,83,152,159,89,1 08,113,117,128,129,133,34 09:36:11.626 SERIAL » [ACK] (0x06) 09:36:11.628 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:36:11.631 SERIAL » 0x010a00131a0370050e2508a9 (12 bytes) 09:36:11.632 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 8 └─[ConfigurationCCGet] parameter #: 14 09:36:11.632 CNTRLR « [Node 029] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:36:11.633 CNTRLR » [Node 029] querying capabilities for endpoint #2... 09:36:11.645 SERIAL « [ACK] (0x06) 09:36:11.646 SERIAL « 0x0104011301e8 (6 bytes) 09:36:11.647 SERIAL » [ACK] (0x06) 09:36:11.649 DRIVER « [RES] [SendData] was sent: true 09:36:11.718 SERIAL « 0x0107001308000008eb (9 bytes) 09:36:11.718 SERIAL » [ACK] (0x06) 09:36:11.720 DRIVER « [REQ] [SendData] callback id: 8 transmit status: OK 09:36:11.731 SERIAL « 0x010b0004001a0570060e010096 (13 bytes) 09:36:11.746 CNTRLR [Node 026] [~] [Configuration] 14: 0 => 0 09:36:11.749 SERIAL » [ACK] (0x06) 09:36:11.750 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 0 09:36:11.756 SERIAL » 0x010a00131d036009022509bf (12 bytes) 09:36:11.756 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 9 └─[MultiChannelCCCapabilityGet] endpoint: 2 09:36:11.757 CNTRLR « [Node 026] parameter #14 has value: 0 09:36:11.757 CNTRLR » [Node 026] querying parameter #17 value... 09:36:11.762 SERIAL « [ACK] (0x06) 09:36:11.765 SERIAL « 0x0104011301e8 (6 bytes) 09:36:11.765 SERIAL » [ACK] (0x06) 09:36:11.766 DRIVER « [RES] [SendData] was sent: true 09:36:11.822 SERIAL « 0x0107001309000007e5 (9 bytes) 09:36:11.822 SERIAL » [ACK] (0x06) 09:36:11.822 DRIVER « [REQ] [SendData] callback id: 9 transmit status: OK 09:36:11.908 SERIAL « 0x01160004001d10600a0221015e8e31989f596c718085222d (24 bytes) 09:36:11.909 CNTRLR [Node 029] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 2] [internal] 49,152,159,89,108,113,128,133,34 => 94,142,49,152,159,89,108,113,128,133,34 09:36:11.910 SERIAL » [ACK] (0x06) 09:36:11.911 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:36:11.918 SERIAL » 0x0109001306029840250a16 (11 bytes) 09:36:11.918 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 10 └─[SecurityCCNonceGet] 09:36:11.919 CNTRLR « [Node 029] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:36:11.919 CNTRLR [Node 029] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:36:11.956 SERIAL « [ACK] (0x06) 09:36:11.959 SERIAL « 0x0104011301e8 (6 bytes) 09:36:11.959 SERIAL » [ACK] (0x06) 09:36:11.960 DRIVER « [RES] [SendData] was sent: true 09:36:11.962 CNTRLR [Node 029] BatteryCC: doing a partial interview... 09:36:11.963 CNTRLR » [Node 029] querying battery status... 09:36:13.260 SERIAL « 0x010700130a00008564 (9 bytes) 09:36:13.260 SERIAL » [ACK] (0x06) 09:36:13.260 DRIVER « [REQ] [SendData] callback id: 10 transmit status: OK 09:36:13.282 SERIAL « 0x0110000400060a98808d6b3c0fa8d8df36b3 (18 bytes) 09:36:13.283 SERIAL » [ACK] (0x06) 09:36:13.283 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x8d6b3c0fa8d8df36 09:36:13.286 SERIAL » 0x01210013061a9881b5cacd1b67a03157f0dd0b6c6bff398d93bb2c9adbc337da2 (35 bytes) 50bef 09:36:13.287 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 11 └─[SecurityCCCommandEncapsulation] │ nonce id: 141 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 09:36:13.289 SERIAL « [ACK] (0x06) 09:36:13.297 SERIAL « 0x0104011301e8 (6 bytes) 09:36:13.297 SERIAL » [ACK] (0x06) 09:36:13.297 DRIVER « [RES] [SendData] was sent: true 09:36:13.322 SERIAL « 0x010700130b000003e3 (9 bytes) 09:36:13.323 SERIAL » [ACK] (0x06) 09:36:13.323 DRIVER « [REQ] [SendData] callback id: 11 transmit status: OK 09:36:13.374 SERIAL « 0x010c000400030631050422052fca (14 bytes) 09:36:13.375 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:13.376 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 140.6 => 132.7 [Endpoint 0] 09:36:13.376 SERIAL » [ACK] (0x06) 09:36:13.377 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 132.7 09:36:13.440 SERIAL « 0x0108000400060298402f (10 bytes) 09:36:13.440 SERIAL » [ACK] (0x06) 09:36:13.441 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:36:13.445 SERIAL » 0x01110013060a9880fb0cd6224a4c8b2924006a (19 bytes) 09:36:13.445 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xfb0cd6224a4c8b29 09:36:13.447 SERIAL « [ACK] (0x06) 09:36:13.454 SERIAL « 0x0104011301e8 (6 bytes) 09:36:13.454 SERIAL » [ACK] (0x06) 09:36:13.455 DRIVER « [RES] [SendData] was sent: true 09:36:13.501 SERIAL « 0x0121000400061b9881c8d0aff36685f743c5002f58a2b53fd5fbbed9190cab917 (35 bytes) 8bef7 09:36:13.502 SERIAL » [ACK] (0x06) 09:36:13.503 CNTRLR [Node 006] [~] [Protection] local: 0 => 0 [Endpoint 1] 09:36:13.504 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ProtectionCCReport] local: Unprotected 09:36:13.507 SERIAL » 0x010900131d028002250c51 (11 bytes) 09:36:13.507 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 12 └─[BatteryCCGet] 09:36:13.508 CNTRLR « [Node 006] received protection status: local: Unprotected 09:36:13.508 CNTRLR [Node 006] [~] [Protection] interviewComplete: true => [Endpoint 1] [internal] true 09:36:13.537 SERIAL « [ACK] (0x06) 09:36:13.541 SERIAL « 0x0104011301e8 (6 bytes) 09:36:13.542 SERIAL » [ACK] (0x06) 09:36:13.543 DRIVER « [RES] [SendData] was sent: true 09:36:13.545 CNTRLR [Node 006] BatteryCC: doing a partial interview... [Endpoint 1] 09:36:13.545 CNTRLR » [Node 006] querying battery status... [Endpoint 1] 09:36:14.922 SERIAL « 0x010700130c00008d6a (9 bytes) 09:36:14.922 SERIAL » [ACK] (0x06) 09:36:14.923 DRIVER « [REQ] [SendData] callback id: 12 transmit status: OK 09:36:15.001 SERIAL « 0x010c0004100306310504220aac56 (14 bytes) 09:36:15.003 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:15.004 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 132.7 => 273.2 [Endpoint 0] 09:36:15.005 SERIAL » [ACK] (0x06) 09:36:15.006 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 273.2 09:36:15.071 SERIAL « 0x01090004001d038003630c (11 bytes) 09:36:15.073 CNTRLR [Node 029] [~] [Battery] level: 99 => 99 [Endpoint 0] 09:36:15.074 CNTRLR [Node 029] [~] [Battery] isLow: false => false [Endpoint 0] 09:36:15.074 SERIAL » [ACK] (0x06) 09:36:15.076 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 99 is low: false 09:36:15.081 SERIAL » 0x010f00131608600d000231040100250d8e (17 bytes) 09:36:15.082 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 13 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:36:15.083 CNTRLR « [Node 029] received response for battery information: level: 99 09:36:15.084 CNTRLR [Node 029] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:36:15.135 SERIAL « [ACK] (0x06) 09:36:15.140 SERIAL « 0x0104011301e8 (6 bytes) 09:36:15.140 SERIAL » [ACK] (0x06) 09:36:15.142 DRIVER « [RES] [SendData] was sent: true 09:36:15.146 CNTRLR [Node 029] WakeUpCC: doing a partial interview... 09:36:15.146 CNTRLR [Node 029] skipping wakeup configuration for frequent listening device 09:36:15.146 CNTRLR [Node 029] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:36:15.150 CNTRLR [Node 029] ZWavePlusCC: doing a partial interview... [Endpoint 1] 09:36:15.150 CNTRLR [Node 029] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 09:36:15.151 CNTRLR [Node 029] ThermostatModeCC: doing a partial interview... [Endpoint 1] 09:36:15.151 CNTRLR » [Node 029] querying current thermostat mode... [Endpoint 1] 09:36:15.189 SERIAL « 0x010c0004100306310504220aac56 (14 bytes) 09:36:15.190 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:15.191 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 273.2 => 273.2 [Endpoint 0] 09:36:15.192 SERIAL » [ACK] (0x06) 09:36:15.193 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 273.2 09:36:15.212 SERIAL « 0x010c0004100306310504220aac56 (14 bytes) 09:36:15.213 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:15.214 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 273.2 => 273.2 [Endpoint 0] 09:36:15.214 SERIAL » [ACK] (0x06) 09:36:15.215 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 273.2 09:36:15.324 SERIAL « 0x010c000400030631050422050aef (14 bytes) 09:36:15.324 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:15.325 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 273.2 => 129 [Endpoint 0] 09:36:15.325 SERIAL » [ACK] (0x06) 09:36:15.328 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 129 09:36:15.364 SERIAL « 0x010c0004100306310504220aac56 (14 bytes) 09:36:15.365 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:15.365 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 129 => 273.2 [Endpoint 0] 09:36:15.366 SERIAL » [ACK] (0x06) 09:36:15.367 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 273.2 09:36:15.375 SERIAL « 0x010c0004100306310504220aac56 (14 bytes) 09:36:15.376 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:15.376 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 273.2 => 273.2 [Endpoint 0] 09:36:15.376 SERIAL » [ACK] (0x06) 09:36:15.377 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 273.2 09:36:15.437 SERIAL « 0x010c0004100306310504220aac56 (14 bytes) 09:36:15.438 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:15.439 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 273.2 => 273.2 [Endpoint 0] 09:36:15.439 SERIAL » [ACK] (0x06) 09:36:15.440 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 273.2 09:36:15.467 SERIAL « 0x010c000400030631050422050aef (14 bytes) 09:36:15.468 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:15.469 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 273.2 => 129 [Endpoint 0] 09:36:15.469 SERIAL » [ACK] (0x06) 09:36:15.470 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 129 09:36:15.487 SERIAL « 0x010c0004100306310504220aac56 (14 bytes) 09:36:15.488 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:15.488 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 129 => 273.2 [Endpoint 0] 09:36:15.489 SERIAL » [ACK] (0x06) 09:36:15.490 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 273.2 09:36:15.555 SERIAL « 0x010c000400030631050422050aef (14 bytes) 09:36:15.556 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:15.557 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 273.2 => 129 [Endpoint 0] 09:36:15.557 SERIAL » [ACK] (0x06) 09:36:15.558 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 129 09:36:16.825 SERIAL « 0x010c0004100306310504220aac56 (14 bytes) 09:36:16.826 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:16.827 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 129 => 273.2 [Endpoint 0] 09:36:16.828 SERIAL » [ACK] (0x06) 09:36:16.829 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 273.2 09:36:16.847 SERIAL « 0x010c0004100306310504220aac56 (14 bytes) 09:36:16.848 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:16.848 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 273.2 => 273.2 [Endpoint 0] 09:36:16.849 SERIAL » [ACK] (0x06) 09:36:16.850 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 273.2 09:36:16.860 SERIAL « 0x010700130d0000b254 (9 bytes) 09:36:16.861 SERIAL » [ACK] (0x06) 09:36:16.861 DRIVER « [REQ] [SendData] callback id: 13 transmit status: OK 09:36:16.954 SERIAL « 0x0110000400160a600d02003105012200af20 (18 bytes) 09:36:16.955 CNTRLR [Node 022] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:36:16.956 CNTRLR [Node 022] [~] [Multilevel Sensor] Air temperature: 17.5 => 17.5 [Endpoint 2] 09:36:16.956 SERIAL » [ACK] (0x06) 09:36:16.958 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 17.5 09:36:16.961 SERIAL » 0x010d00131d06600d00014002250eff (15 bytes) 09:36:16.962 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 14 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:36:16.962 CNTRLR « [Node 022] received current Air temperature sensor reading: 17.5 [Endpoint 2] °C 09:36:16.963 CNTRLR [Node 022] [~] [Multilevel Sensor] interviewComplete: [Endpoint 2] [internal] true => true 09:36:16.991 SERIAL « [ACK] (0x06) 09:36:16.992 SERIAL « 0x0104011301e8 (6 bytes) 09:36:16.992 SERIAL » [ACK] (0x06) 09:36:16.995 DRIVER « [RES] [SendData] was sent: true 09:36:16.998 CNTRLR [Node 022] NotificationCC: doing a partial interview... [Endpoint 2] 09:36:16.999 CNTRLR [Node 022] [~] [Notification] interviewComplete: true [Endpoint 2] [internal] => true 09:36:16.999 CNTRLR [Node 022] BatteryCC: doing a partial interview... [Endpoint 2] 09:36:17.000 CNTRLR » [Node 022] querying battery status... [Endpoint 2] 09:36:18.406 SERIAL « 0x010700130e00009075 (9 bytes) 09:36:18.407 SERIAL » [ACK] (0x06) 09:36:18.408 DRIVER « [REQ] [SendData] callback id: 14 transmit status: OK 09:36:18.523 SERIAL « 0x010d0004001d07600d0100400301c2 (15 bytes) 09:36:18.525 CNTRLR [Node 029] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 09:36:18.526 SERIAL » [ACK] (0x06) 09:36:18.528 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 09:36:18.535 SERIAL » 0x010a00131c03600902250fb8 (12 bytes) 09:36:18.536 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 15 └─[MultiChannelCCCapabilityGet] endpoint: 2 09:36:18.537 CNTRLR « [Node 029] received current thermostat mode: Heat [Endpoint 1] 09:36:18.538 CNTRLR [Node 029] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 1] [internal] ue => true 09:36:18.600 SERIAL « [ACK] (0x06) 09:36:18.604 SERIAL « 0x0104011301e8 (6 bytes) 09:36:18.605 SERIAL » [ACK] (0x06) 09:36:18.605 DRIVER « [RES] [SendData] was sent: true 09:36:18.615 CNTRLR [Node 029] ThermostatSetpointCC: doing a partial interview... [Endpoint 1] 09:36:18.616 CNTRLR » [Node 029] querying current value of setpoint Heating... [Endpoint 1] 09:36:19.993 SERIAL « 0x010700130f00009276 (9 bytes) 09:36:19.994 SERIAL » [ACK] (0x06) 09:36:19.995 DRIVER « [REQ] [SendData] callback id: 15 transmit status: OK 09:36:20.081 SERIAL « 0x01160004001c10600a0221015e8e31989f596c718085222c (24 bytes) 09:36:20.082 CNTRLR [Node 028] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 2] [internal] 49,152,159,89,108,113,128,133,34 => 94,142,49,152,159,89,108,113,128,133,34 09:36:20.083 SERIAL » [ACK] (0x06) 09:36:20.084 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:36:20.090 SERIAL » 0x010e00131d07600d00014302012510e1 (16 bytes) 09:36:20.091 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:36:20.092 CNTRLR « [Node 028] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:36:20.093 CNTRLR [Node 028] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:36:20.143 SERIAL « [ACK] (0x06) 09:36:20.147 SERIAL « 0x0104011300e9 (6 bytes) 09:36:20.148 SERIAL » [ACK] (0x06) 09:36:20.149 DRIVER « [RES] [SendData] was sent: false 09:36:20.150 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 09:36:20.152 SERIAL « 0x010c0004100306310504220ab64c (14 bytes) 09:36:20.153 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:20.154 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 273.2 => 274.2 [Endpoint 0] 09:36:20.154 SERIAL » [ACK] (0x06) 09:36:20.159 CNTRLR [Node 028] BatteryCC: doing a partial interview... 09:36:20.160 CNTRLR » [Node 028] querying battery status... 09:36:20.163 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 274.2 09:36:20.164 SERIAL « 0x010c0004100306310504220ab64c (14 bytes) 09:36:20.165 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:20.166 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 274.2 => 274.2 [Endpoint 0] 09:36:20.166 SERIAL » [ACK] (0x06) 09:36:20.171 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 274.2 09:36:20.200 SERIAL « 0x010c0004100306310504220ab64c (14 bytes) 09:36:20.201 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:20.202 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 274.2 => 274.2 [Endpoint 0] 09:36:20.202 SERIAL » [ACK] (0x06) 09:36:20.203 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 274.2 09:36:20.251 SERIAL » 0x010e00131d07600d00014302012510e1 (16 bytes) 09:36:20.251 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:36:20.253 SERIAL « [ACK] (0x06) 09:36:20.260 SERIAL « 0x0104011301e8 (6 bytes) 09:36:20.260 SERIAL » [ACK] (0x06) 09:36:20.261 DRIVER « [RES] [SendData] was sent: true 09:36:20.269 SERIAL « 0x010c0004100306310504220ab64c (14 bytes) 09:36:20.270 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:20.271 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 274.2 => 274.2 [Endpoint 0] 09:36:20.271 SERIAL » [ACK] (0x06) 09:36:20.273 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 274.2 09:36:20.348 SERIAL « 0x010c0004100306310504220ab64c (14 bytes) 09:36:20.349 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:20.349 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 274.2 => 274.2 [Endpoint 0] 09:36:20.350 SERIAL » [ACK] (0x06) 09:36:20.354 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 274.2 09:36:20.497 SERIAL « 0x010c0004100306310504220ab64c (14 bytes) 09:36:20.498 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:20.499 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 274.2 => 274.2 [Endpoint 0] 09:36:20.500 SERIAL » [ACK] (0x06) 09:36:20.501 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 274.2 09:36:20.517 SERIAL « 0x010c0004100306310504220ab64c (14 bytes) 09:36:20.518 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:20.518 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 274.2 => 274.2 [Endpoint 0] 09:36:20.519 SERIAL » [ACK] (0x06) 09:36:20.520 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 274.2 09:36:20.530 SERIAL « 0x010c0004100306310504220ab64c (14 bytes) 09:36:20.531 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:20.532 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 274.2 => 274.2 [Endpoint 0] 09:36:20.533 SERIAL » [ACK] (0x06) 09:36:20.534 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 274.2 09:36:20.562 SERIAL « 0x010c0004100306310504220ab64c (14 bytes) 09:36:20.564 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:20.564 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 274.2 => 274.2 [Endpoint 0] 09:36:20.565 SERIAL » [ACK] (0x06) 09:36:20.567 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 274.2 09:36:20.586 SERIAL « 0x010c0004100306310504220ab64c (14 bytes) 09:36:20.587 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:20.588 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 274.2 => 274.2 [Endpoint 0] 09:36:20.589 SERIAL » [ACK] (0x06) 09:36:20.591 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 274.2 09:36:20.609 SERIAL « 0x010c0004100306310504220ab64c (14 bytes) 09:36:20.610 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:20.611 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 274.2 => 274.2 [Endpoint 0] 09:36:20.612 SERIAL » [ACK] (0x06) 09:36:20.614 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 274.2 09:36:20.660 SERIAL « 0x010c0004100306310504220ab64c (14 bytes) 09:36:20.660 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:20.661 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 274.2 => 274.2 [Endpoint 0] 09:36:20.661 SERIAL » [ACK] (0x06) 09:36:20.662 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 274.2 09:36:26.632 SERIAL « 0x01100004001d0a600d01004303012200a053 (18 bytes) 09:36:26.634 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpoint[1]: 16 => 16 [Endpoint 1] 09:36:26.634 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 09:36:26.634 SERIAL » [ACK] (0x06) 09:36:26.635 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 16 °C 09:36:26.661 SERIAL « 0x01100004001d0a600d01004303012200a053 (18 bytes) 09:36:26.662 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpoint[1]: 16 => 16 [Endpoint 1] 09:36:26.663 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 09:36:26.663 SERIAL » [ACK] (0x06) 09:36:26.664 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 16 °C 09:36:26.690 SERIAL « 0x01100004001d0a600d01004303012200a053 (18 bytes) 09:36:26.691 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpoint[1]: 16 => 16 [Endpoint 1] 09:36:26.691 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 09:36:26.695 SERIAL » [ACK] (0x06) 09:36:26.696 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 16 °C 09:36:26.855 SERIAL « 0x01100004001d0a600d01004303012200a053 (18 bytes) 09:36:26.855 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpoint[1]: 16 => 16 [Endpoint 1] 09:36:26.856 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 09:36:26.856 SERIAL » [ACK] (0x06) 09:36:26.857 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 16 °C 09:36:26.923 SERIAL « 0x010700131000029b62 (9 bytes) 09:36:26.923 SERIAL » [ACK] (0x06) 09:36:26.923 DRIVER « [REQ] [SendData] callback id: 16 transmit status: OK 09:36:28.526 CNTRLR [Node 029] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:36:29.031 SERIAL » 0x010e00131d07600d00014302012510e1 (16 bytes) 09:36:29.032 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:36:29.034 SERIAL « [ACK] (0x06) 09:36:29.040 SERIAL « 0x0104011301e8 (6 bytes) 09:36:29.041 SERIAL » [ACK] (0x06) 09:36:29.041 DRIVER « [RES] [SendData] was sent: true 09:36:30.511 SERIAL « 0x01070013100000946f (9 bytes) 09:36:30.512 SERIAL » [ACK] (0x06) 09:36:30.512 DRIVER « [REQ] [SendData] callback id: 16 transmit status: OK 09:36:30.605 SERIAL « 0x01100004001d0a600d01004303012200a053 (18 bytes) 09:36:30.607 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpoint[1]: 16 => 16 [Endpoint 1] 09:36:30.608 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 09:36:30.608 SERIAL » [ACK] (0x06) 09:36:30.610 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 16 °C 09:36:30.617 SERIAL » 0x010a001312036009022511a8 (12 bytes) 09:36:30.618 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 17 └─[MultiChannelCCCapabilityGet] endpoint: 2 09:36:30.619 CNTRLR « [Node 029] received current value of setpoint Heating: 16 °C [Endpoint 1] 09:36:30.620 CNTRLR [Node 029] [~] [Thermostat Setpoint] interviewComplete [Endpoint 1] [internal] : true => true 09:36:30.694 SERIAL « [ACK] (0x06) 09:36:30.700 SERIAL « 0x0104011301e8 (6 bytes) 09:36:30.701 SERIAL » [ACK] (0x06) 09:36:30.703 DRIVER « [RES] [SendData] was sent: true 09:36:30.708 CNTRLR [Node 029] NotificationCC: doing a partial interview... [Endpoint 1] 09:36:30.709 CNTRLR » [Node 029] querying notification status for Power Management... [Endpoint 1] 09:36:30.729 SERIAL « 0x010700131100000af0 (9 bytes) 09:36:30.729 SERIAL » [ACK] (0x06) 09:36:30.730 DRIVER « [REQ] [SendData] callback id: 17 transmit status: OK 09:36:30.814 SERIAL « 0x01160004001210600a0221015e8e31989f596c7180852222 (24 bytes) 09:36:30.815 CNTRLR [Node 018] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 2] [internal] 49,152,159,89,108,113,128,133,34 => 94,142,49,152,159,89,108,113,128,133,34 09:36:30.815 SERIAL » [ACK] (0x06) 09:36:30.815 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:36:30.818 SERIAL » 0x011000131d09600d000171040008002512ce (18 bytes) 09:36:30.819 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 18 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: Power Management 09:36:30.819 CNTRLR « [Node 018] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:36:30.820 CNTRLR [Node 018] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:36:30.820 CNTRLR [Node 018] BatteryCC: doing a partial interview... 09:36:30.820 CNTRLR » [Node 018] querying battery status... 09:36:30.823 SERIAL « [ACK] (0x06) 09:36:30.827 SERIAL « 0x0104011301e8 (6 bytes) 09:36:30.828 SERIAL » [ACK] (0x06) 09:36:30.828 DRIVER « [RES] [SendData] was sent: true 09:36:30.967 SERIAL « 0x010700131200000ef7 (9 bytes) 09:36:30.967 SERIAL » [ACK] (0x06) 09:36:30.967 DRIVER « [REQ] [SendData] callback id: 18 transmit status: OK 09:36:31.054 SERIAL « 0x01130004001d0d600d01007105000000ff08fe00e9 (21 bytes) 09:36:31.055 SERIAL » [ACK] (0x06) 09:36:31.056 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 09:36:31.059 SERIAL » 0x010a001318037005092513b7 (12 bytes) 09:36:31.060 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 19 └─[ConfigurationCCGet] parameter #: 9 09:36:31.060 CNTRLR [Node 029] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 1] 54 09:36:31.061 CNTRLR » [Node 029] querying notification status for System... [Endpoint 1] 09:36:31.065 SERIAL « [ACK] (0x06) 09:36:31.068 SERIAL « 0x0104011301e8 (6 bytes) 09:36:31.068 SERIAL » [ACK] (0x06) 09:36:31.068 DRIVER « [RES] [SendData] was sent: true 09:36:31.150 SERIAL « 0x0107001313000009f1 (9 bytes) 09:36:31.151 SERIAL » [ACK] (0x06) 09:36:31.151 DRIVER « [REQ] [SendData] callback id: 19 transmit status: OK 09:36:31.164 SERIAL « 0x010b0004001805700609010192 (13 bytes) 09:36:31.170 CNTRLR [Node 024] [~] [Configuration] 9: 1 => 1 09:36:31.171 SERIAL » [ACK] (0x06) 09:36:31.171 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 1 value: 1 09:36:31.174 SERIAL » 0x011000131d09600d000171040009002514c9 (18 bytes) 09:36:31.175 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 20 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: System 09:36:31.175 CNTRLR « [Node 024] parameter #9 has value: 1 09:36:31.175 CNTRLR » [Node 024] querying parameter #10 value... 09:36:31.178 SERIAL « [ACK] (0x06) 09:36:31.184 SERIAL « 0x0104011301e8 (6 bytes) 09:36:31.185 SERIAL » [ACK] (0x06) 09:36:31.186 DRIVER « [RES] [SendData] was sent: true 09:36:31.271 SERIAL « 0x010700131400000af5 (9 bytes) 09:36:31.271 SERIAL » [ACK] (0x06) 09:36:31.272 DRIVER « [REQ] [SendData] callback id: 20 transmit status: OK 09:36:31.364 SERIAL « 0x01130004001d0d600d01007105000000ff09fe00e8 (21 bytes) 09:36:31.364 SERIAL » [ACK] (0x06) 09:36:31.365 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: System notification status: 255 notification event: Unknown (0xfe) 09:36:31.370 SERIAL » 0x010a00131a037005112515ab (12 bytes) 09:36:31.370 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 21 └─[ConfigurationCCGet] parameter #: 17 09:36:31.371 CNTRLR [Node 029] [~] [Notification] System[unknown]: 254 => 254 [Endpoint 1] 09:36:31.372 CNTRLR [Node 029] [~] [Notification] interviewComplete: true [Endpoint 1] [internal] => true 09:36:31.402 SERIAL « [ACK] (0x06) 09:36:31.406 SERIAL « 0x0104011301e8 (6 bytes) 09:36:31.406 SERIAL » [ACK] (0x06) 09:36:31.408 DRIVER « [RES] [SendData] was sent: true 09:36:31.410 CNTRLR [Node 029] ProtectionCC: doing a partial interview... 09:36:31.411 CNTRLR » [Node 029] querying protection status... 09:36:31.457 SERIAL « 0x0107001315000008f6 (9 bytes) 09:36:31.458 SERIAL » [ACK] (0x06) 09:36:31.462 DRIVER « [REQ] [SendData] callback id: 21 transmit status: OK 09:36:31.467 SERIAL « 0x010b0004001a05700611010a83 (13 bytes) 09:36:31.477 CNTRLR [Node 026] [~] [Configuration] 17: 10 => 10 09:36:31.479 SERIAL » [ACK] (0x06) 09:36:31.480 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 17 value size: 1 value: 10 09:36:31.485 SERIAL » 0x010d00131d06600d000175022516d2 (15 bytes) 09:36:31.486 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 22 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 09:36:31.486 CNTRLR « [Node 026] parameter #17 has value: 10 09:36:31.486 CNTRLR » [Node 026] querying parameter #18 value... 09:36:31.492 SERIAL « [ACK] (0x06) 09:36:31.495 SERIAL « 0x0104011301e8 (6 bytes) 09:36:31.495 SERIAL » [ACK] (0x06) 09:36:31.497 DRIVER « [RES] [SendData] was sent: true 09:36:31.578 SERIAL « 0x0107001316000009f4 (9 bytes) 09:36:31.578 SERIAL » [ACK] (0x06) 09:36:31.579 DRIVER « [REQ] [SendData] callback id: 22 transmit status: OK 09:36:31.659 SERIAL « 0x010d0004001d07600d0100750300f6 (15 bytes) 09:36:31.660 CNTRLR [Node 029] [~] [Protection] local: 0 => 0 [Endpoint 1] 09:36:31.661 SERIAL » [ACK] (0x06) 09:36:31.662 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ProtectionCCReport] local: Unprotected 09:36:31.667 SERIAL » 0x010900130602984025170b (11 bytes) 09:36:31.667 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 23 └─[SecurityCCNonceGet] 09:36:31.668 CNTRLR « [Node 029] received protection status: local: Unprotected 09:36:31.668 CNTRLR [Node 029] [~] [Protection] interviewComplete: true => [Endpoint 1] [internal] true 09:36:31.698 SERIAL « [ACK] (0x06) 09:36:31.701 SERIAL « 0x0104011301e8 (6 bytes) 09:36:31.702 SERIAL » [ACK] (0x06) 09:36:31.703 DRIVER « [RES] [SendData] was sent: true 09:36:31.706 CNTRLR [Node 029] BatteryCC: doing a partial interview... [Endpoint 1] 09:36:31.707 CNTRLR » [Node 029] querying battery status... [Endpoint 1] 09:36:33.024 SERIAL « 0x010700131700008874 (9 bytes) 09:36:33.025 SERIAL » [ACK] (0x06) 09:36:33.025 DRIVER « [REQ] [SendData] callback id: 23 transmit status: OK 09:36:33.047 SERIAL « 0x0110000400060a9880e69a399fec359b5334 (18 bytes) 09:36:33.047 SERIAL » [ACK] (0x06) 09:36:33.048 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xe69a399fec359b53 09:36:33.052 SERIAL » 0x01210013061a9881de3330baaa77b2a96f66702d0d0b58e658177403c4d6268e2 (35 bytes) 5183a 09:36:33.052 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 24 └─[SecurityCCCommandEncapsulation] │ nonce id: 230 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BatteryCCGet] 09:36:33.055 SERIAL « [ACK] (0x06) 09:36:33.063 SERIAL « 0x0104011301e8 (6 bytes) 09:36:33.063 SERIAL » [ACK] (0x06) 09:36:33.063 DRIVER « [RES] [SendData] was sent: true 09:36:33.088 SERIAL « 0x0107001318000003f0 (9 bytes) 09:36:33.088 SERIAL » [ACK] (0x06) 09:36:33.089 DRIVER « [REQ] [SendData] callback id: 24 transmit status: OK 09:36:33.205 SERIAL « 0x0108000400060298402f (10 bytes) 09:36:33.206 SERIAL » [ACK] (0x06) 09:36:33.206 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:36:33.214 SERIAL » 0x01110013060a988045c77f8bd1de38d724005b (19 bytes) 09:36:33.214 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x45c77f8bd1de38d7 09:36:33.216 SERIAL « [ACK] (0x06) 09:36:33.223 SERIAL « 0x0104011301e8 (6 bytes) 09:36:33.223 SERIAL » [ACK] (0x06) 09:36:33.224 DRIVER « [RES] [SendData] was sent: true 09:36:33.265 SERIAL « 0x0121000400061b9881c3649b9210d63b3663787206353d276f45fc999cbd8d91c (35 bytes) 1f5bd 09:36:33.266 SERIAL » [ACK] (0x06) 09:36:33.267 CNTRLR [Node 006] [~] [Battery] level: 89 => 89 [Endpoint 1] 09:36:33.268 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 1] 09:36:33.268 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BatteryCCReport] level: 89 is low: false 09:36:33.271 SERIAL » 0x010d00131d06600d00018002251928 (15 bytes) 09:36:33.271 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 25 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BatteryCCGet] 09:36:33.273 CNTRLR « [Node 006] received response for battery information: [Endpoint 1] level: 89 09:36:33.273 CNTRLR [Node 006] [~] [Battery] interviewComplete: true => tr [Endpoint 1] [internal] ue 09:36:33.306 SERIAL « [ACK] (0x06) 09:36:33.307 SERIAL « 0x0104011301e8 (6 bytes) 09:36:33.307 SERIAL » [ACK] (0x06) 09:36:33.309 DRIVER « [RES] [SendData] was sent: true 09:36:33.312 CNTRLR [Node 006] ClockCC: doing a partial interview... 09:36:33.312 CNTRLR » [Node 006] requesting current clock setting... 09:36:34.819 SERIAL « 0x010700131900009a68 (9 bytes) 09:36:34.820 SERIAL » [ACK] (0x06) 09:36:34.821 DRIVER « [REQ] [SendData] callback id: 25 transmit status: OK 09:36:34.935 SERIAL « 0x010d0004001d07600d010080036360 (15 bytes) 09:36:34.937 CNTRLR [Node 029] [~] [Battery] level: 99 => 99 [Endpoint 1] 09:36:34.938 CNTRLR [Node 029] [~] [Battery] isLow: false => false [Endpoint 1] 09:36:34.938 SERIAL » [ACK] (0x06) 09:36:34.940 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BatteryCCReport] level: 99 is low: false 09:36:34.945 SERIAL » 0x010d00131606600d00028002251a23 (15 bytes) 09:36:34.946 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 26 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[BatteryCCGet] 09:36:34.946 CNTRLR « [Node 029] received response for battery information: [Endpoint 1] level: 99 09:36:34.947 CNTRLR [Node 029] [~] [Battery] interviewComplete: true => tr [Endpoint 1] [internal] ue 09:36:35.004 SERIAL « [ACK] (0x06) 09:36:35.009 SERIAL « 0x0104011301e8 (6 bytes) 09:36:35.010 SERIAL » [ACK] (0x06) 09:36:35.012 DRIVER « [RES] [SendData] was sent: true 09:36:35.016 CNTRLR [Node 029] ClockCC: doing a partial interview... 09:36:35.016 CNTRLR » [Node 029] requesting current clock setting... 09:36:36.437 SERIAL « 0x010700131a00009564 (9 bytes) 09:36:36.438 SERIAL » [ACK] (0x06) 09:36:36.438 DRIVER « [REQ] [SendData] callback id: 26 transmit status: OK 09:36:36.551 SERIAL « 0x010d0004001607600d02008003515a (15 bytes) 09:36:36.552 CNTRLR [Node 022] [~] [Battery] level: 81 => 81 [Endpoint 2] 09:36:36.553 CNTRLR [Node 022] [~] [Battery] isLow: false => false [Endpoint 2] 09:36:36.554 SERIAL » [ACK] (0x06) 09:36:36.555 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BatteryCCReport] level: 81 is low: false 09:36:36.558 SERIAL » 0x010d00131d06600d00018105251b2c (15 bytes) 09:36:36.559 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 27 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ClockCCGet] 09:36:36.560 CNTRLR « [Node 022] received response for battery information: [Endpoint 2] level: 81 09:36:36.560 CNTRLR [Node 022] [~] [Battery] interviewComplete: true => tr [Endpoint 2] [internal] ue 09:36:36.589 SERIAL « [ACK] (0x06) 09:36:36.594 SERIAL « 0x0104011301e8 (6 bytes) 09:36:36.595 SERIAL » [ACK] (0x06) 09:36:36.597 DRIVER « [RES] [SendData] was sent: true 09:36:36.598 CNTRLR [Node 022] MultilevelSensorCC: doing a partial interview... 09:36:36.599 CNTRLR » [Node 022] querying Air temperature sensor reading... 09:36:38.142 SERIAL « 0x010700131b00009e6e (9 bytes) 09:36:38.143 SERIAL » [ACK] (0x06) 09:36:38.144 DRIVER « [REQ] [SendData] callback id: 27 transmit status: OK 09:36:38.260 SERIAL « 0x010e0004001d08600d01008106e924c6 (16 bytes) 09:36:38.261 SERIAL » [ACK] (0x06) 09:36:38.262 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ClockCCReport] clock setting: Sunday, 09:36 09:36:38.269 SERIAL » 0x010900131c028002251c40 (11 bytes) 09:36:38.270 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 28 └─[BatteryCCGet] 09:36:38.276 CNTRLR « [Node 029] received current clock setting: Sunday, 09:36 09:36:38.277 CNTRLR [Node 029] [~] [Clock] interviewComplete: true => true [Endpoint 1] [internal] 09:36:38.360 SERIAL « [ACK] (0x06) 09:36:38.362 SERIAL « 0x0104011301e8 (6 bytes) 09:36:38.362 SERIAL » [ACK] (0x06) 09:36:38.363 DRIVER « [RES] [SendData] was sent: true 09:36:38.756 CNTRLR [Node 029] ZWavePlusCC: doing a partial interview... [Endpoint 2] 09:36:38.756 CNTRLR [Node 029] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 09:36:38.757 CNTRLR [Node 029] MultilevelSensorCC: doing a partial interview... [Endpoint 2] 09:36:38.757 CNTRLR » [Node 029] querying Air temperature sensor reading... [Endpoint 2] 09:36:39.717 SERIAL « 0x010700131c00009067 (9 bytes) 09:36:39.717 SERIAL » [ACK] (0x06) 09:36:39.717 DRIVER « [REQ] [SendData] callback id: 28 transmit status: OK 09:36:39.801 SERIAL « 0x01090004001c038003640a (11 bytes) 09:36:39.802 CNTRLR [Node 028] [~] [Battery] level: 100 => 100 [Endpoint 0] 09:36:39.802 CNTRLR [Node 028] [~] [Battery] isLow: false => false [Endpoint 0] 09:36:39.802 SERIAL » [ACK] (0x06) 09:36:39.803 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 09:36:39.806 SERIAL » 0x010f00131d08600d000231040100251d95 (17 bytes) 09:36:39.807 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 29 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:36:39.807 CNTRLR « [Node 028] received response for battery information: level: 100 09:36:39.807 CNTRLR [Node 028] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:36:39.839 SERIAL « [ACK] (0x06) 09:36:39.840 SERIAL « 0x0104011301e8 (6 bytes) 09:36:39.840 SERIAL » [ACK] (0x06) 09:36:39.841 DRIVER « [RES] [SendData] was sent: true 09:36:39.844 CNTRLR [Node 028] ZWavePlusCC: doing a partial interview... [Endpoint 1] 09:36:39.845 CNTRLR [Node 028] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 09:36:39.845 CNTRLR [Node 028] ThermostatModeCC: doing a partial interview... [Endpoint 1] 09:36:39.845 CNTRLR » [Node 028] querying current thermostat mode... [Endpoint 1] 09:36:41.411 SERIAL « 0x010700131d0000a157 (9 bytes) 09:36:41.412 SERIAL » [ACK] (0x06) 09:36:41.413 DRIVER « [REQ] [SendData] callback id: 29 transmit status: OK 09:36:41.509 SERIAL « 0x010c000400030631050422055ebb (14 bytes) 09:36:41.511 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:41.512 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 274.2 => 137.4 [Endpoint 0] 09:36:41.513 SERIAL » [ACK] (0x06) 09:36:41.515 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 137.4 09:36:41.635 SERIAL « 0x01100004001d0a600d02003105012200b733 (18 bytes) 09:36:41.637 CNTRLR [Node 029] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:36:41.638 CNTRLR [Node 029] [~] [Multilevel Sensor] Air temperature: 18.3 => 18.3 [Endpoint 2] 09:36:41.639 SERIAL » [ACK] (0x06) 09:36:41.641 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.3 09:36:41.647 SERIAL » 0x0109001312028002251e4c (11 bytes) 09:36:41.648 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 30 └─[BatteryCCGet] 09:36:41.649 CNTRLR « [Node 029] received current Air temperature sensor reading: 18.3 [Endpoint 2] °C 09:36:41.649 CNTRLR [Node 029] [~] [Multilevel Sensor] interviewComplete: [Endpoint 2] [internal] true => true 09:36:41.709 SERIAL « [ACK] (0x06) 09:36:41.714 SERIAL « 0x0104011301e8 (6 bytes) 09:36:41.715 SERIAL » [ACK] (0x06) 09:36:41.717 DRIVER « [RES] [SendData] was sent: true 09:36:41.721 CNTRLR [Node 029] NotificationCC: doing a partial interview... [Endpoint 2] 09:36:41.722 CNTRLR » [Node 029] querying notification status for Power Management... [Endpoint 2] 09:36:41.787 SERIAL « 0x010700131e00000df8 (9 bytes) 09:36:41.787 SERIAL » [ACK] (0x06) 09:36:41.788 DRIVER « [REQ] [SendData] callback id: 30 transmit status: OK 09:36:43.317 SERIAL « 0x010c0004000306310504220b0fe4 (14 bytes) 09:36:43.318 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:43.319 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 137.4 => 283.1 [Endpoint 0] 09:36:43.319 SERIAL » [ACK] (0x06) 09:36:43.320 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 283.1 09:36:43.391 CNTRLR [Node 018] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:36:43.894 SERIAL » 0x0109001312028002251e4c (11 bytes) 09:36:43.895 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 30 └─[BatteryCCGet] 09:36:43.896 SERIAL « [ACK] (0x06) 09:36:43.902 SERIAL « 0x0104011301e8 (6 bytes) 09:36:43.903 SERIAL » [ACK] (0x06) 09:36:43.903 DRIVER « [RES] [SendData] was sent: true 09:36:43.950 SERIAL « 0x010700131e000005f0 (9 bytes) 09:36:43.950 SERIAL » [ACK] (0x06) 09:36:43.951 DRIVER « [REQ] [SendData] callback id: 30 transmit status: OK 09:36:44.317 SERIAL « 0x010c0004000306310504220800e8 (14 bytes) 09:36:44.318 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:44.319 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 283.1 => 204.8 [Endpoint 0] 09:36:44.320 SERIAL » [ACK] (0x06) 09:36:44.322 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 204.8 09:36:45.554 CNTRLR [Node 018] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:36:46.058 SERIAL » 0x0109001312028002251e4c (11 bytes) 09:36:46.059 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 30 └─[BatteryCCGet] 09:36:46.061 SERIAL « [ACK] (0x06) 09:36:46.067 SERIAL « 0x0104011301e8 (6 bytes) 09:36:46.068 SERIAL » [ACK] (0x06) 09:36:46.069 DRIVER « [RES] [SendData] was sent: true 09:36:46.114 SERIAL « 0x010700131e000005f0 (9 bytes) 09:36:46.115 SERIAL » [ACK] (0x06) 09:36:46.116 DRIVER « [REQ] [SendData] callback id: 30 transmit status: OK 09:36:47.317 SERIAL « 0x010c00040003063105042204fc18 (14 bytes) 09:36:47.318 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:47.319 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 204.8 => 127.6 [Endpoint 0] 09:36:47.320 SERIAL » [ACK] (0x06) 09:36:47.322 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 127.6 09:36:47.730 SERIAL » 0x011000131d09600d00027104000800251fc0 (18 bytes) 09:36:47.732 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 31 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: Power Management 09:36:47.733 CNTRLR [Node 018] Battery status query timed out - skipping because it is not critica l... 09:36:47.733 CNTRLR [Node 018] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:36:47.793 SERIAL « [ACK] (0x06) 09:36:47.799 SERIAL « 0x0104011301e8 (6 bytes) 09:36:47.799 SERIAL » [ACK] (0x06) 09:36:47.801 DRIVER « [RES] [SendData] was sent: true 09:36:47.804 CNTRLR [Node 018] ZWavePlusCC: doing a partial interview... [Endpoint 1] 09:36:47.804 CNTRLR [Node 018] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 09:36:47.805 CNTRLR [Node 018] ThermostatModeCC: doing a partial interview... [Endpoint 1] 09:36:47.805 CNTRLR » [Node 018] querying current thermostat mode... [Endpoint 1] 09:36:49.214 SERIAL « 0x010700131f00009460 (9 bytes) 09:36:49.214 SERIAL » [ACK] (0x06) 09:36:49.216 DRIVER « [REQ] [SendData] callback id: 31 transmit status: OK 09:36:49.303 SERIAL « 0x01100004001d0a600d02003105012200bb3f (18 bytes) 09:36:49.304 CNTRLR [Node 029] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:36:49.305 CNTRLR [Node 029] [~] [Multilevel Sensor] Air temperature: 18.3 => 18.7 [Endpoint 2] 09:36:49.306 SERIAL » [ACK] (0x06) 09:36:49.307 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.7 09:36:49.400 SERIAL « 0x01130004001d0d600d02007105000000ff08fe00ea (21 bytes) 09:36:49.401 SERIAL » [ACK] (0x06) 09:36:49.402 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 09:36:49.406 SERIAL » 0x010a0013180370050a252087 (12 bytes) 09:36:49.406 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 32 └─[ConfigurationCCGet] parameter #: 10 09:36:49.408 CNTRLR [Node 029] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 2] 54 09:36:49.409 CNTRLR » [Node 029] querying notification status for System... [Endpoint 2] 09:36:49.415 SERIAL « [ACK] (0x06) 09:36:49.416 SERIAL « 0x0104011301e8 (6 bytes) 09:36:49.417 SERIAL » [ACK] (0x06) 09:36:49.417 DRIVER « [RES] [SendData] was sent: true 09:36:49.490 SERIAL « 0x0107001320000009c2 (9 bytes) 09:36:49.491 SERIAL » [ACK] (0x06) 09:36:49.492 DRIVER « [REQ] [SendData] callback id: 32 transmit status: OK 09:36:49.504 SERIAL « 0x010b000400180570060a010090 (13 bytes) 09:36:49.513 CNTRLR [Node 024] [~] [Configuration] 10: 0 => 0 09:36:49.514 SERIAL » [ACK] (0x06) 09:36:49.515 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 0 09:36:49.519 SERIAL » 0x011000131d09600d000271040009002521ff (18 bytes) 09:36:49.519 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 33 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:36:49.520 CNTRLR « [Node 024] parameter #10 has value: 0 09:36:49.520 CNTRLR » [Node 024] querying parameter #11 value... 09:36:49.523 SERIAL « [ACK] (0x06) 09:36:49.528 SERIAL « 0x0104011301e8 (6 bytes) 09:36:49.528 SERIAL » [ACK] (0x06) 09:36:49.529 DRIVER « [RES] [SendData] was sent: true 09:36:49.547 SERIAL « 0x010c00040003063105042205d336 (14 bytes) 09:36:49.548 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:49.549 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 127.6 => 149.1 [Endpoint 0] 09:36:49.549 SERIAL » [ACK] (0x06) 09:36:49.550 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 149.1 09:36:49.629 SERIAL « 0x010700132100000ac0 (9 bytes) 09:36:49.630 SERIAL » [ACK] (0x06) 09:36:49.630 DRIVER « [REQ] [SendData] callback id: 33 transmit status: OK 09:36:49.725 SERIAL « 0x010c00040003063105042205d336 (14 bytes) 09:36:49.726 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:36:49.727 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 149.1 => 149.1 [Endpoint 0] 09:36:49.727 SERIAL » [ACK] (0x06) 09:36:49.729 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 149.1 09:36:51.233 CNTRLR [Node 029] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:36:51.738 SERIAL » 0x011000131d09600d000271040009002521ff (18 bytes) 09:36:51.739 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 33 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:36:51.742 SERIAL « [ACK] (0x06) 09:36:51.749 SERIAL « 0x0104011301e8 (6 bytes) 09:36:51.749 SERIAL » [ACK] (0x06) 09:36:51.750 DRIVER « [RES] [SendData] was sent: true 09:36:53.292 SERIAL « 0x010700132100009b51 (9 bytes) 09:36:53.293 SERIAL » [ACK] (0x06) 09:36:53.293 DRIVER « [REQ] [SendData] callback id: 33 transmit status: OK 09:36:54.901 CNTRLR [Node 029] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:36:55.405 SERIAL » 0x011000131d09600d000271040009002521ff (18 bytes) 09:36:55.406 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 33 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:36:55.407 SERIAL « [ACK] (0x06) 09:36:55.414 SERIAL « 0x0104011301e8 (6 bytes) 09:36:55.414 SERIAL » [ACK] (0x06) 09:36:55.415 DRIVER « [RES] [SendData] was sent: true 09:36:56.870 SERIAL « 0x010700132100009258 (9 bytes) 09:36:56.871 SERIAL » [ACK] (0x06) 09:36:56.872 DRIVER « [REQ] [SendData] callback id: 33 transmit status: OK 09:36:58.479 SERIAL » 0x010a00131a0370051225229f (12 bytes) 09:36:58.480 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 34 └─[ConfigurationCCGet] parameter #: 18 09:36:58.480 CNTRLR [Node 029] Interview attempt 2/5 failed, retrying in 10000 ms... 09:36:58.483 SERIAL « [ACK] (0x06) 09:36:58.489 SERIAL « 0x0104011301e8 (6 bytes) 09:36:58.490 SERIAL » [ACK] (0x06) 09:36:58.491 DRIVER « [RES] [SendData] was sent: true 09:36:58.505 SERIAL « 0x0107001322000002cb (9 bytes) 09:36:58.506 SERIAL » [ACK] (0x06) 09:36:58.506 DRIVER « [REQ] [SendData] callback id: 34 transmit status: OK 09:36:58.516 SERIAL « 0x010b0004001a05700612010a80 (13 bytes) 09:36:58.521 CNTRLR [Node 026] [~] [Configuration] 18: 10 => 10 09:36:58.521 SERIAL » [ACK] (0x06) 09:36:58.522 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 18 value size: 1 value: 10 09:36:58.527 SERIAL » 0x010900130602984025233f (11 bytes) 09:36:58.527 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 35 └─[SecurityCCNonceGet] 09:36:58.527 CNTRLR « [Node 026] parameter #18 has value: 10 09:36:58.527 CNTRLR » [Node 026] querying parameter #22 value... 09:36:58.530 SERIAL « [ACK] (0x06) 09:36:58.535 SERIAL « 0x0104011301e8 (6 bytes) 09:36:58.535 SERIAL » [ACK] (0x06) 09:36:58.536 DRIVER « [RES] [SendData] was sent: true 09:36:59.755 SERIAL « 0x010700132300007bb3 (9 bytes) 09:36:59.756 SERIAL » [ACK] (0x06) 09:36:59.757 DRIVER « [REQ] [SendData] callback id: 35 transmit status: OK 09:36:59.778 SERIAL « 0x0110000400060a98808d8d9371e49ede8138 (18 bytes) 09:36:59.778 SERIAL » [ACK] (0x06) 09:36:59.780 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x8d8d9371e49ede81 09:36:59.786 SERIAL » 0x01210013061a9881bf9a297f7d5cc3d9e393c2e0b0ee768d2a4ded79587810f42 (35 bytes) 52441 09:36:59.787 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 36 └─[SecurityCCCommandEncapsulation] │ nonce id: 141 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ClockCCGet] 09:36:59.791 SERIAL « [ACK] (0x06) 09:36:59.798 SERIAL « 0x0104011301e8 (6 bytes) 09:36:59.798 SERIAL » [ACK] (0x06) 09:36:59.799 DRIVER « [RES] [SendData] was sent: true 09:36:59.823 SERIAL « 0x0107001324000003cc (9 bytes) 09:36:59.824 SERIAL » [ACK] (0x06) 09:36:59.825 DRIVER « [REQ] [SendData] callback id: 36 transmit status: OK 09:36:59.940 SERIAL « 0x0108000400060298402f (10 bytes) 09:36:59.941 SERIAL » [ACK] (0x06) 09:36:59.942 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:36:59.950 SERIAL » 0x01110013060a988090f882b1d1335b0a240025 (19 bytes) 09:36:59.951 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x90f882b1d1335b0a 09:36:59.958 SERIAL « [ACK] (0x06) 09:36:59.965 SERIAL « 0x0104011301e8 (6 bytes) 09:36:59.965 SERIAL » [ACK] (0x06) 09:36:59.966 DRIVER « [RES] [SendData] was sent: true 09:37:00.008 SERIAL « 0x0122000400061c98819b5a8135edc12866d054d0d2aca0f5dc28900bb4fa81774 (36 bytes) f1f5366 09:37:00.009 SERIAL » [ACK] (0x06) 09:37:00.011 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ClockCCReport] clock setting: Sunday, 09:30 09:37:00.017 SERIAL » 0x010b00131604310401002525c1 (13 bytes) 09:37:00.018 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 37 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:37:00.018 CNTRLR « [Node 006] received current clock setting: Sunday, 09:30 09:37:00.019 CNTRLR [Node 006] [~] [Clock] interviewComplete: true => true [Endpoint 1] [internal] 09:37:00.087 SERIAL « [ACK] (0x06) 09:37:00.093 SERIAL « 0x0104011301e8 (6 bytes) 09:37:00.094 SERIAL » [ACK] (0x06) 09:37:00.095 DRIVER « [RES] [SendData] was sent: true 09:37:00.102 CNTRLR [Node 006] ZWavePlusCC: doing a partial interview... [Endpoint 2] 09:37:00.103 CNTRLR [Node 006] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 09:37:00.104 CNTRLR [Node 006] MultilevelSensorCC: doing a partial interview... [Endpoint 2] 09:37:00.104 CNTRLR » [Node 006] querying Air temperature sensor reading... [Endpoint 2] 09:37:01.406 SERIAL « 0x010700132500008a44 (9 bytes) 09:37:01.407 SERIAL » [ACK] (0x06) 09:37:01.408 DRIVER « [REQ] [SendData] callback id: 37 transmit status: OK 09:37:01.520 SERIAL « 0x010c00040016063105012200af5f (14 bytes) 09:37:01.521 CNTRLR [Node 022] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 09:37:01.521 CNTRLR [Node 022] [~] [Multilevel Sensor] Air temperature: 18.2 => 17.5 [Endpoint 0] 09:37:01.522 SERIAL » [ACK] (0x06) 09:37:01.522 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 17.5 09:37:01.527 SERIAL » 0x010d00131c06600d000140022526d6 (15 bytes) 09:37:01.527 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 38 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:37:01.528 CNTRLR « [Node 022] received current Air temperature sensor reading: 17.5 °C 09:37:01.528 CNTRLR [Node 022] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 09:37:01.573 SERIAL « [ACK] (0x06) 09:37:01.577 SERIAL « 0x0104011301e8 (6 bytes) 09:37:01.578 SERIAL » [ACK] (0x06) 09:37:01.579 DRIVER « [RES] [SendData] was sent: true 09:37:01.582 CNTRLR [Node 022] ThermostatModeCC: doing a partial interview... 09:37:01.583 CNTRLR » [Node 022] querying current thermostat mode... 09:37:03.001 SERIAL « 0x010700132600009459 (9 bytes) 09:37:03.002 SERIAL » [ACK] (0x06) 09:37:03.003 DRIVER « [REQ] [SendData] callback id: 38 transmit status: OK 09:37:03.117 SERIAL « 0x010d0004001c07600d0100400301c3 (15 bytes) 09:37:03.118 CNTRLR [Node 028] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 09:37:03.119 SERIAL » [ACK] (0x06) 09:37:03.121 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 09:37:03.128 SERIAL » 0x010d00131206600d000140022527d9 (15 bytes) 09:37:03.129 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:37:03.129 CNTRLR « [Node 028] received current thermostat mode: Heat [Endpoint 1] 09:37:03.130 CNTRLR [Node 028] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 1] [internal] ue => true 09:37:03.195 SERIAL « [ACK] (0x06) 09:37:03.200 SERIAL « 0x0104011301e8 (6 bytes) 09:37:03.201 SERIAL » [ACK] (0x06) 09:37:03.203 DRIVER « [RES] [SendData] was sent: true 09:37:03.207 CNTRLR [Node 028] ThermostatSetpointCC: doing a partial interview... [Endpoint 1] 09:37:03.208 CNTRLR » [Node 028] querying current value of setpoint Heating... [Endpoint 1] 09:37:03.239 SERIAL « 0x010700132700000ac6 (9 bytes) 09:37:03.240 SERIAL » [ACK] (0x06) 09:37:03.240 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 09:37:04.845 CNTRLR [Node 018] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:37:05.360 SERIAL » 0x010d00131206600d000140022527d9 (15 bytes) 09:37:05.362 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:37:05.364 SERIAL « [ACK] (0x06) 09:37:05.371 SERIAL « 0x0104011301e8 (6 bytes) 09:37:05.371 SERIAL » [ACK] (0x06) 09:37:05.372 DRIVER « [RES] [SendData] was sent: true 09:37:05.420 SERIAL « 0x0107001327000005c9 (9 bytes) 09:37:05.421 SERIAL » [ACK] (0x06) 09:37:05.422 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 09:37:07.024 CNTRLR [Node 018] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:37:07.529 SERIAL » 0x010d00131206600d000140022527d9 (15 bytes) 09:37:07.530 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:37:07.532 SERIAL « [ACK] (0x06) 09:37:07.538 SERIAL « 0x0104011301e8 (6 bytes) 09:37:07.539 SERIAL » [ACK] (0x06) 09:37:07.540 DRIVER « [RES] [SendData] was sent: true 09:37:07.587 SERIAL « 0x0107001327000005c9 (9 bytes) 09:37:07.588 SERIAL » [ACK] (0x06) 09:37:07.589 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 09:37:08.480 CNTRLR [Node 029] Beginning interview - last completed stage: RestartFromCache 09:37:08.481 CNTRLR » [Node 029] pinging the node... 09:37:09.203 SERIAL » 0x010800131d01002528f5 (10 bytes) 09:37:09.204 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 40 └─[NoOperationCC] 09:37:09.205 CNTRLR [Node 018] Failed all interview attempts, giving up. 09:37:09.207 SERIAL « [ACK] (0x06) 09:37:09.212 SERIAL « 0x0104011301e8 (6 bytes) 09:37:09.213 SERIAL » [ACK] (0x06) 09:37:09.214 DRIVER « [RES] [SendData] was sent: true 09:37:10.696 SERIAL « 0x010c0004100306310504220b4cb7 (14 bytes) 09:37:10.697 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:10.698 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 149.1 => 289.2 [Endpoint 0] 09:37:10.699 SERIAL » [ACK] (0x06) 09:37:10.701 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 289.2 09:37:10.707 SERIAL « 0x010700132800009655 (9 bytes) 09:37:10.708 SERIAL » [ACK] (0x06) 09:37:10.709 DRIVER « [REQ] [SendData] callback id: 40 transmit status: OK 09:37:10.717 SERIAL » 0x010a0013180370050b25298f (12 bytes) 09:37:10.718 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 41 └─[ConfigurationCCGet] parameter #: 11 09:37:10.719 CNTRLR « [Node 029] ping successful 09:37:10.724 CNTRLR [Node 029] ManufacturerSpecificCC: doing a partial interview... 09:37:10.725 CNTRLR [Node 029] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:37:10.801 SERIAL « [ACK] (0x06) 09:37:10.803 SERIAL « 0x0104011301e8 (6 bytes) 09:37:10.803 SERIAL » [ACK] (0x06) 09:37:10.806 DRIVER « [RES] [SendData] was sent: true 09:37:10.808 SERIAL « 0x0107001329000002c0 (9 bytes) 09:37:10.808 SERIAL » [ACK] (0x06) 09:37:10.809 CNTRLR [Node 029] VersionCC: doing a partial interview... 09:37:10.810 CNTRLR [Node 029] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:37:10.810 CNTRLR [Node 029] trying to load device config 09:37:10.812 DRIVER « [REQ] [SendData] callback id: 41 transmit status: OK 09:37:10.814 SERIAL « 0x010b000400180570060b010091 (13 bytes) 09:37:10.819 CNTRLR [Node 024] [~] [Configuration] 11: 0 => 0 09:37:10.820 SERIAL » [ACK] (0x06) 09:37:10.821 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 11 value size: 1 value: 0 09:37:10.824 SERIAL » 0x010a00131a03700516252a93 (12 bytes) 09:37:10.824 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 42 └─[ConfigurationCCGet] parameter #: 22 09:37:10.825 CNTRLR « [Node 024] parameter #11 has value: 0 09:37:10.825 CNTRLR » [Node 024] querying parameter #12 value... 09:37:10.831 CNTRLR [Node 029] device config loaded 09:37:10.832 CNTRLR [Node 029] ZWavePlusCC: doing a partial interview... 09:37:10.832 CNTRLR [Node 029] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:37:10.833 CNTRLR » [Node 029] querying device endpoint information... 09:37:10.835 SERIAL « 0x010c0004100306310504220b4cb7 (14 bytes) 09:37:10.836 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:10.837 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 289.2 => 289.2 [Endpoint 0] 09:37:10.838 SERIAL » [ACK] (0x06) 09:37:10.838 SERIAL « [CAN] (0x18) 09:37:10.839 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 09:37:10.841 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 289.2 09:37:10.845 SERIAL « 0x010c0004100306310504220b4cb7 (14 bytes) 09:37:10.845 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:10.846 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 289.2 => 289.2 [Endpoint 0] 09:37:10.847 SERIAL » [ACK] (0x06) 09:37:10.848 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 289.2 09:37:10.903 SERIAL « 0x010c0004100306310504220b4cb7 (14 bytes) 09:37:10.909 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:10.910 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 289.2 => 289.2 [Endpoint 0] 09:37:10.910 SERIAL » [ACK] (0x06) 09:37:10.911 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 289.2 09:37:10.941 SERIAL » 0x010a00131a03700516252a93 (12 bytes) 09:37:10.941 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 42 └─[ConfigurationCCGet] parameter #: 22 09:37:10.943 SERIAL « [ACK] (0x06) 09:37:10.949 SERIAL « 0x0104011301e8 (6 bytes) 09:37:10.950 SERIAL » [ACK] (0x06) 09:37:10.950 DRIVER « [RES] [SendData] was sent: true 09:37:10.967 SERIAL « 0x010700132a000002c3 (9 bytes) 09:37:10.967 SERIAL » [ACK] (0x06) 09:37:10.968 DRIVER « [REQ] [SendData] callback id: 42 transmit status: OK 09:37:10.978 SERIAL « 0x010c0004001a067006160200f079 (14 bytes) 09:37:10.985 CNTRLR [Node 026] [~] [Configuration] 22: 240 => 240 09:37:10.986 SERIAL » [ACK] (0x06) 09:37:10.987 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 240 09:37:10.990 SERIAL » 0x010900131d026007252b93 (11 bytes) 09:37:10.991 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 43 └─[MultiChannelCCEndPointGet] 09:37:10.991 CNTRLR « [Node 026] parameter #22 has value: 240 09:37:10.991 CNTRLR » [Node 026] querying parameter #29 value... 09:37:11.030 SERIAL « [ACK] (0x06) 09:37:11.031 SERIAL « 0x0104011301e8 (6 bytes) 09:37:11.032 SERIAL » [ACK] (0x06) 09:37:11.033 DRIVER « [RES] [SendData] was sent: true 09:37:11.049 SERIAL « 0x010c0004100306310504220b4cb7 (14 bytes) 09:37:11.050 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:11.050 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 289.2 => 289.2 [Endpoint 0] 09:37:11.051 SERIAL » [ACK] (0x06) 09:37:11.052 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 289.2 09:37:11.085 SERIAL « 0x010700132b000009c9 (9 bytes) 09:37:11.086 SERIAL » [ACK] (0x06) 09:37:11.086 DRIVER « [REQ] [SendData] callback id: 43 transmit status: OK 09:37:11.127 SERIAL « 0x010c0004100306310504220b4cb7 (14 bytes) 09:37:11.128 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:11.129 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 289.2 => 289.2 [Endpoint 0] 09:37:11.129 SERIAL » [ACK] (0x06) 09:37:11.130 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 289.2 09:37:11.174 SERIAL « 0x010b0004001d05600800020082 (13 bytes) 09:37:11.175 CNTRLR [Node 029] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:37:11.175 CNTRLR [Node 029] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 09:37:11.175 CNTRLR [Node 029] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:37:11.175 CNTRLR [Node 029] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 09:37:11.175 SERIAL » [ACK] (0x06) 09:37:11.176 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:37:11.182 SERIAL » 0x0109001306029840252c30 (11 bytes) 09:37:11.183 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 44 └─[SecurityCCNonceGet] 09:37:11.183 CNTRLR « [Node 029] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:37:11.184 CNTRLR » [Node 029] querying all endpoints... 09:37:11.186 SERIAL « 0x010c0004100306310504220b4cb7 (14 bytes) 09:37:11.187 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:11.187 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 289.2 => 289.2 [Endpoint 0] 09:37:11.188 SERIAL » [ACK] (0x06) 09:37:11.188 SERIAL « [CAN] (0x18) 09:37:11.189 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 09:37:11.190 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 289.2 09:37:11.289 SERIAL » 0x0109001306029840252c30 (11 bytes) 09:37:11.290 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 44 └─[SecurityCCNonceGet] 09:37:11.291 SERIAL « [ACK] (0x06) 09:37:11.297 SERIAL « 0x0104011301e8 (6 bytes) 09:37:11.298 SERIAL » [ACK] (0x06) 09:37:11.298 DRIVER « [RES] [SendData] was sent: true 09:37:11.368 SERIAL « 0x010c0004100306310504220b4cb7 (14 bytes) 09:37:11.369 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:11.369 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 289.2 => 289.2 [Endpoint 0] 09:37:11.370 SERIAL » [ACK] (0x06) 09:37:11.371 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 289.2 09:37:11.378 SERIAL « 0x010c0004100306310504220b4cb7 (14 bytes) 09:37:11.379 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:11.379 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 289.2 => 289.2 [Endpoint 0] 09:37:11.379 SERIAL » [ACK] (0x06) 09:37:11.380 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 289.2 09:37:12.553 SERIAL « 0x010c0004100306310504220b4cb7 (14 bytes) 09:37:12.553 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:12.554 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 289.2 => 289.2 [Endpoint 0] 09:37:12.554 SERIAL » [ACK] (0x06) 09:37:12.562 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 289.2 09:37:12.573 SERIAL « 0x0110000400060a9880edda4a01016e7176eb (18 bytes) 09:37:12.574 SERIAL » [ACK] (0x06) 09:37:12.574 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xedda4a01016e7176 09:37:13.731 SERIAL « 0x010700132c0000f433 (9 bytes) 09:37:13.732 SERIAL » [ACK] (0x06) 09:37:13.733 DRIVER « [REQ] [SendData] callback id: 44 transmit status: OK 09:37:13.761 SERIAL « 0x0110000400060a988017755229371318f12b (18 bytes) 09:37:13.762 SERIAL » [ACK] (0x06) 09:37:13.765 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x17755229371318f1 09:37:13.772 SERIAL » 0x01230013061c98811a8fcc4068aa6e84b0a9d6c5531160ad901751b80a3c92d39 (37 bytes) 1a2252d5a 09:37:13.773 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 45 └─[SecurityCCCommandEncapsulation] │ nonce id: 23 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:37:13.777 SERIAL « [ACK] (0x06) 09:37:13.784 SERIAL « 0x0104011301e8 (6 bytes) 09:37:13.785 SERIAL » [ACK] (0x06) 09:37:13.786 DRIVER « [RES] [SendData] was sent: true 09:37:13.810 SERIAL « 0x010700132d000003c5 (9 bytes) 09:37:13.810 SERIAL » [ACK] (0x06) 09:37:13.811 DRIVER « [REQ] [SendData] callback id: 45 transmit status: OK 09:37:13.935 SERIAL « 0x0108000400060298402f (10 bytes) 09:37:13.936 SERIAL » [ACK] (0x06) 09:37:13.937 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:37:13.950 SERIAL » 0x01110013060a9880cb91d8a196598a542400ff (19 bytes) 09:37:13.951 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xcb91d8a196598a54 09:37:13.953 SERIAL « [ACK] (0x06) 09:37:13.960 SERIAL « 0x0104011301e8 (6 bytes) 09:37:13.960 SERIAL » [ACK] (0x06) 09:37:13.961 DRIVER « [RES] [SendData] was sent: true 09:37:14.003 SERIAL « 0x0124000400061e9881549a88721a23068b93cbd2fff3809d3b1f8f92cbbb067c5 (38 bytes) df8cc91fcf2 09:37:14.004 SERIAL » [ACK] (0x06) 09:37:14.006 CNTRLR [Node 006] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:37:14.007 CNTRLR [Node 006] [~] [Multilevel Sensor] Air temperature: 21.8 => 21.5 [Endpoint 2] 09:37:14.008 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 21.5 09:37:14.013 SERIAL » 0x010b00131d04600bffff252e9e (13 bytes) 09:37:14.014 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 46 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:37:14.015 CNTRLR « [Node 006] received current Air temperature sensor reading: 21.5 [Endpoint 2] °C 09:37:14.016 CNTRLR [Node 006] [~] [Multilevel Sensor] interviewComplete: [Endpoint 2] [internal] true => true 09:37:14.071 SERIAL « [ACK] (0x06) 09:37:14.075 SERIAL « 0x0104011301e8 (6 bytes) 09:37:14.075 SERIAL » [ACK] (0x06) 09:37:14.077 DRIVER « [RES] [SendData] was sent: true 09:37:14.079 CNTRLR [Node 006] NotificationCC: doing a partial interview... [Endpoint 2] 09:37:14.079 CNTRLR » [Node 006] querying notification status for Power Management... [Endpoint 2] 09:37:15.543 SERIAL « 0x010700132e0000995c (9 bytes) 09:37:15.543 SERIAL » [ACK] (0x06) 09:37:15.544 DRIVER « [REQ] [SendData] callback id: 46 transmit status: OK 09:37:15.625 SERIAL « 0x010d0004001d07600c00ffff010283 (15 bytes) 09:37:15.626 SERIAL » [ACK] (0x06) 09:37:15.627 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 09:37:15.633 SERIAL » 0x0109001316024002252fb9 (11 bytes) 09:37:15.634 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 47 └─[ThermostatModeCCGet] 09:37:15.635 CNTRLR « [Node 029] received endpoints: 1, 2 09:37:15.635 CNTRLR » [Node 029] querying capabilities for endpoint #1... 09:37:15.641 SERIAL « [ACK] (0x06) 09:37:15.643 SERIAL « 0x0104011301e8 (6 bytes) 09:37:15.643 SERIAL » [ACK] (0x06) 09:37:15.645 DRIVER « [RES] [SendData] was sent: true 09:37:17.036 SERIAL « 0x010700132f00008c48 (9 bytes) 09:37:17.036 SERIAL » [ACK] (0x06) 09:37:17.037 DRIVER « [REQ] [SendData] callback id: 47 transmit status: OK 09:37:17.148 SERIAL « 0x01090004001603400301a5 (11 bytes) 09:37:17.149 CNTRLR [Node 022] [~] [Thermostat Mode] mode: 0 => 1 [Endpoint 0] 09:37:17.149 SERIAL » [ACK] (0x06) 09:37:17.150 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ThermostatModeCCReport] mode: Heat 09:37:17.153 SERIAL » 0x010a00131d03600901253085 (12 bytes) 09:37:17.153 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 48 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:37:17.156 CNTRLR « [Node 022] received current thermostat mode: Heat 09:37:17.157 CNTRLR [Node 022] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 0] [internal] ue => true 09:37:17.193 SERIAL « [ACK] (0x06) 09:37:17.197 SERIAL « 0x0104011301e8 (6 bytes) 09:37:17.197 SERIAL » [ACK] (0x06) 09:37:17.199 DRIVER « [RES] [SendData] was sent: true 09:37:17.200 CNTRLR [Node 022] ThermostatSetpointCC: doing a partial interview... 09:37:17.200 CNTRLR » [Node 022] querying current value of setpoint Heating... 09:37:18.735 SERIAL « 0x010700133000009e45 (9 bytes) 09:37:18.735 SERIAL » [ACK] (0x06) 09:37:18.736 DRIVER « [REQ] [SendData] callback id: 48 transmit status: OK 09:37:18.831 SERIAL « 0x011a0004001d14600a0108065e8e404353989f596c7175808185229d (28 bytes) 09:37:18.833 CNTRLR [Node 029] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 1] [internal] 64,67,83,152,159,89,108,113,117,128,129,133,34 => 94,142,64,67,83,152,159,89,1 08,113,117,128,129,133,34 09:37:18.833 SERIAL » [ACK] (0x06) 09:37:18.834 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:37:18.849 SERIAL » 0x010e00131c07600d00014302012531c1 (16 bytes) 09:37:18.850 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 49 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:37:18.851 CNTRLR « [Node 029] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:37:18.851 CNTRLR » [Node 029] querying capabilities for endpoint #2... 09:37:18.856 SERIAL « [ACK] (0x06) 09:37:18.859 SERIAL « 0x0104011301e8 (6 bytes) 09:37:18.859 SERIAL » [ACK] (0x06) 09:37:18.860 DRIVER « [RES] [SendData] was sent: true 09:37:20.261 SERIAL « 0x010700133100008c56 (9 bytes) 09:37:20.261 SERIAL » [ACK] (0x06) 09:37:20.262 DRIVER « [REQ] [SendData] callback id: 49 transmit status: OK 09:37:20.381 SERIAL « 0x01100004001c0a600d010043030122006496 (18 bytes) 09:37:20.382 CNTRLR [Node 028] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 1] 09:37:20.383 CNTRLR [Node 028] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 09:37:20.383 SERIAL » [ACK] (0x06) 09:37:20.384 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 09:37:20.388 SERIAL » 0x010a00131d03600902253284 (12 bytes) 09:37:20.389 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 50 └─[MultiChannelCCCapabilityGet] endpoint: 2 09:37:20.389 CNTRLR « [Node 028] received current value of setpoint Heating: 10 °C [Endpoint 1] 09:37:20.390 CNTRLR [Node 028] [~] [Thermostat Setpoint] interviewComplete [Endpoint 1] [internal] : true => true 09:37:20.435 SERIAL « [ACK] (0x06) 09:37:20.439 SERIAL « 0x0104011301e8 (6 bytes) 09:37:20.440 SERIAL » [ACK] (0x06) 09:37:20.442 DRIVER « [RES] [SendData] was sent: true 09:37:20.446 CNTRLR [Node 028] NotificationCC: doing a partial interview... [Endpoint 1] 09:37:20.446 CNTRLR [Node 028] [~] [Notification] interviewComplete: true [Endpoint 1] [internal] => true 09:37:20.447 CNTRLR [Node 028] ProtectionCC: doing a partial interview... 09:37:20.447 CNTRLR » [Node 028] querying protection status... 09:37:21.983 SERIAL « 0x010700133200009f46 (9 bytes) 09:37:21.983 SERIAL » [ACK] (0x06) 09:37:21.984 DRIVER « [REQ] [SendData] callback id: 50 transmit status: OK 09:37:22.072 SERIAL « 0x01160004001d10600a0221015e8e31989f596c718085222d (24 bytes) 09:37:22.073 CNTRLR [Node 029] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 2] [internal] 49,152,159,89,108,113,128,133,34 => 94,142,49,152,159,89,108,113,128,133,34 09:37:22.073 SERIAL » [ACK] (0x06) 09:37:22.074 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:37:22.082 SERIAL » 0x010a0013180370050c253392 (12 bytes) 09:37:22.083 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 51 └─[ConfigurationCCGet] parameter #: 12 09:37:22.084 CNTRLR « [Node 029] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:37:22.084 CNTRLR [Node 029] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:37:22.138 SERIAL « [ACK] (0x06) 09:37:22.142 SERIAL « 0x0104011301e8 (6 bytes) 09:37:22.142 SERIAL » [ACK] (0x06) 09:37:22.144 DRIVER « [RES] [SendData] was sent: true 09:37:22.146 CNTRLR [Node 029] BatteryCC: doing a partial interview... 09:37:22.146 CNTRLR » [Node 029] querying battery status... 09:37:22.171 SERIAL « 0x0107001333000009d1 (9 bytes) 09:37:22.171 SERIAL » [ACK] (0x06) 09:37:22.172 DRIVER « [REQ] [SendData] callback id: 51 transmit status: OK 09:37:22.185 SERIAL « 0x010c000400180670060c020032a3 (14 bytes) 09:37:22.190 CNTRLR [Node 024] [~] [Configuration] 12: 50 => 50 09:37:22.191 SERIAL » [ACK] (0x06) 09:37:22.192 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 50 09:37:22.195 SERIAL » 0x010900131d028002253469 (11 bytes) 09:37:22.195 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 52 └─[BatteryCCGet] 09:37:22.195 CNTRLR « [Node 024] parameter #12 has value: 50 09:37:22.197 CNTRLR » [Node 024] querying parameter #13 value... 09:37:22.214 SERIAL « [ACK] (0x06) 09:37:22.216 SERIAL « 0x0104011301e8 (6 bytes) 09:37:22.216 SERIAL » [ACK] (0x06) 09:37:22.218 DRIVER « [RES] [SendData] was sent: true 09:37:22.284 SERIAL « 0x0107001334000009d6 (9 bytes) 09:37:22.284 SERIAL » [ACK] (0x06) 09:37:22.285 DRIVER « [REQ] [SendData] callback id: 52 transmit status: OK 09:37:23.889 CNTRLR [Node 029] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:37:24.395 SERIAL » 0x010900131d028002253469 (11 bytes) 09:37:24.395 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 52 └─[BatteryCCGet] 09:37:24.397 SERIAL « [ACK] (0x06) 09:37:24.403 SERIAL « 0x0104011301e8 (6 bytes) 09:37:24.404 SERIAL » [ACK] (0x06) 09:37:24.410 DRIVER « [RES] [SendData] was sent: true 09:37:24.484 SERIAL « 0x0107001334000009d6 (9 bytes) 09:37:24.485 SERIAL » [ACK] (0x06) 09:37:24.486 DRIVER « [REQ] [SendData] callback id: 52 transmit status: OK 09:37:24.562 SERIAL « 0x01090004001d038003630c (11 bytes) 09:37:24.564 CNTRLR [Node 029] [~] [Battery] level: 99 => 99 [Endpoint 0] 09:37:24.565 CNTRLR [Node 029] [~] [Battery] isLow: false => false [Endpoint 0] 09:37:24.565 SERIAL » [ACK] (0x06) 09:37:24.567 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 99 is low: false 09:37:24.572 SERIAL » 0x010a00131a0370051d253587 (12 bytes) 09:37:24.573 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 53 └─[ConfigurationCCGet] parameter #: 29 09:37:24.574 CNTRLR « [Node 029] received response for battery information: level: 99 09:37:24.574 CNTRLR [Node 029] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:37:24.631 SERIAL « [ACK] (0x06) 09:37:24.635 SERIAL « 0x0104011301e8 (6 bytes) 09:37:24.635 SERIAL » [ACK] (0x06) 09:37:24.637 DRIVER « [RES] [SendData] was sent: true 09:37:24.642 CNTRLR [Node 029] WakeUpCC: doing a partial interview... 09:37:24.642 CNTRLR [Node 029] skipping wakeup configuration for frequent listening device 09:37:24.643 CNTRLR [Node 029] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:37:24.654 CNTRLR [Node 029] ZWavePlusCC: doing a partial interview... [Endpoint 1] 09:37:24.656 CNTRLR [Node 029] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 09:37:24.657 CNTRLR [Node 029] ThermostatModeCC: doing a partial interview... [Endpoint 1] 09:37:24.657 CNTRLR » [Node 029] querying current thermostat mode... [Endpoint 1] 09:37:24.666 SERIAL « 0x0107001335000008d6 (9 bytes) 09:37:24.667 SERIAL » [ACK] (0x06) 09:37:24.668 DRIVER « [REQ] [SendData] callback id: 53 transmit status: OK 09:37:24.674 SERIAL « 0x010b0004001a0570061d010085 (13 bytes) 09:37:24.687 CNTRLR [Node 026] [~] [Configuration] 29: 0 => 0 09:37:24.690 SERIAL » [ACK] (0x06) 09:37:24.691 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 29 value size: 1 value: 0 09:37:24.701 SERIAL » 0x010d00131d06600d000140022536c7 (15 bytes) 09:37:24.703 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 54 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:37:24.703 CNTRLR « [Node 026] parameter #29 has value: 0 09:37:24.704 CNTRLR » [Node 026] querying parameter #30 value... 09:37:24.707 SERIAL « [ACK] (0x06) 09:37:24.712 SERIAL « 0x0104011301e8 (6 bytes) 09:37:24.713 SERIAL » [ACK] (0x06) 09:37:24.714 DRIVER « [RES] [SendData] was sent: true 09:37:24.794 SERIAL « 0x0107001336000009d4 (9 bytes) 09:37:24.795 SERIAL » [ACK] (0x06) 09:37:24.822 DRIVER « [REQ] [SendData] callback id: 54 transmit status: OK 09:37:24.875 SERIAL « 0x010d0004001d07600d0100400301c2 (15 bytes) 09:37:24.876 CNTRLR [Node 029] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 09:37:24.876 SERIAL » [ACK] (0x06) 09:37:24.877 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 09:37:24.882 SERIAL » 0x010900130602984025372b (11 bytes) 09:37:24.882 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 55 └─[SecurityCCNonceGet] 09:37:24.883 CNTRLR « [Node 029] received current thermostat mode: Heat [Endpoint 1] 09:37:24.883 CNTRLR [Node 029] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 1] [internal] ue => true 09:37:24.884 CNTRLR [Node 029] ThermostatSetpointCC: doing a partial interview... [Endpoint 1] 09:37:24.884 CNTRLR » [Node 029] querying current value of setpoint Heating... [Endpoint 1] 09:37:24.887 SERIAL « [ACK] (0x06) 09:37:24.890 SERIAL « 0x0104011301e8 (6 bytes) 09:37:24.890 SERIAL » [ACK] (0x06) 09:37:24.891 DRIVER « [RES] [SendData] was sent: true 09:37:26.205 SERIAL « 0x010700133700008458 (9 bytes) 09:37:26.205 SERIAL » [ACK] (0x06) 09:37:26.206 DRIVER « [REQ] [SendData] callback id: 55 transmit status: OK 09:37:26.227 SERIAL « 0x0110000400060a9880ce1f36dbc551c372e6 (18 bytes) 09:37:26.228 SERIAL » [ACK] (0x06) 09:37:26.228 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xce1f36dbc551c372 09:37:26.231 SERIAL » 0x01240013061d9881098c46fdf4094e3c191f663ce335fb3aec38ce97f0bfaaa45 (38 bytes) 4f030253875 09:37:26.232 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 56 └─[SecurityCCCommandEncapsulation] │ nonce id: 206 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: Power Management 09:37:26.235 SERIAL « [ACK] (0x06) 09:37:26.242 SERIAL « 0x0104011301e8 (6 bytes) 09:37:26.243 SERIAL » [ACK] (0x06) 09:37:26.243 DRIVER « [RES] [SendData] was sent: true 09:37:26.269 SERIAL « 0x0107001338000003d0 (9 bytes) 09:37:26.269 SERIAL » [ACK] (0x06) 09:37:26.269 DRIVER « [REQ] [SendData] callback id: 56 transmit status: OK 09:37:26.291 SERIAL « 0x0108000400060298402f (10 bytes) 09:37:26.292 SERIAL » [ACK] (0x06) 09:37:26.292 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:37:26.299 SERIAL » 0x01110013060a9880e559eda1e4a400c32400be (19 bytes) 09:37:26.299 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xe559eda1e4a400c3 09:37:26.301 SERIAL « [ACK] (0x06) 09:37:26.307 SERIAL « 0x0104011301e8 (6 bytes) 09:37:26.308 SERIAL » [ACK] (0x06) 09:37:26.308 DRIVER « [RES] [SendData] was sent: true 09:37:26.329 SERIAL « 0x010c000400030631050422087890 (14 bytes) 09:37:26.330 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:26.331 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 289.2 => 216.8 [Endpoint 0] 09:37:26.331 SERIAL » [ACK] (0x06) 09:37:26.332 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 216.8 09:37:26.374 SERIAL « 0x0127000400062198811865eeca2e4cfe71b2997dc33bf496f0624d2ba567d3e54 (41 bytes) 8d399ea1a1c99f815 09:37:26.374 SERIAL » [ACK] (0x06) 09:37:26.376 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 09:37:26.379 SERIAL » 0x010e00131d07600d00014302012539c8 (16 bytes) 09:37:26.379 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 57 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:37:26.380 CNTRLR [Node 006] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 2] 54 09:37:26.381 CNTRLR » [Node 006] querying notification status for System... [Endpoint 2] 09:37:26.384 SERIAL « [ACK] (0x06) 09:37:26.387 SERIAL « 0x0104011301e8 (6 bytes) 09:37:26.388 SERIAL » [ACK] (0x06) 09:37:26.388 DRIVER « [RES] [SendData] was sent: true 09:37:26.503 SERIAL « 0x010700133900000cde (9 bytes) 09:37:26.504 SERIAL » [ACK] (0x06) 09:37:26.504 DRIVER « [REQ] [SendData] callback id: 57 transmit status: OK 09:37:27.314 SERIAL « 0x010c00040003063105042204ba5e (14 bytes) 09:37:27.315 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:27.316 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 216.8 => 121 [Endpoint 0] 09:37:27.317 SERIAL » [ACK] (0x06) 09:37:27.318 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 121 09:37:28.107 CNTRLR [Node 029] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:37:28.609 SERIAL » 0x010e00131d07600d00014302012539c8 (16 bytes) 09:37:28.610 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 57 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:37:28.612 SERIAL « [ACK] (0x06) 09:37:28.618 SERIAL « 0x0104011301e8 (6 bytes) 09:37:28.619 SERIAL » [ACK] (0x06) 09:37:28.619 DRIVER « [RES] [SendData] was sent: true 09:37:28.703 SERIAL « 0x0107001339000009db (9 bytes) 09:37:28.703 SERIAL » [ACK] (0x06) 09:37:28.704 DRIVER « [REQ] [SendData] callback id: 57 transmit status: OK 09:37:28.787 SERIAL « 0x01100004001d0a600d01004303012200a053 (18 bytes) 09:37:28.789 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpoint[1]: 16 => 16 [Endpoint 1] 09:37:28.791 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 09:37:28.791 SERIAL » [ACK] (0x06) 09:37:28.793 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 16 °C 09:37:28.799 SERIAL » 0x010a00131603430201253aac (12 bytes) 09:37:28.800 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 58 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:37:28.801 CNTRLR « [Node 029] received current value of setpoint Heating: 16 °C [Endpoint 1] 09:37:28.801 CNTRLR [Node 029] [~] [Thermostat Setpoint] interviewComplete [Endpoint 1] [internal] : true => true 09:37:28.868 SERIAL « [ACK] (0x06) 09:37:28.871 SERIAL « 0x0104011301e8 (6 bytes) 09:37:28.872 SERIAL » [ACK] (0x06) 09:37:28.873 DRIVER « [RES] [SendData] was sent: true 09:37:28.875 CNTRLR [Node 029] NotificationCC: doing a partial interview... [Endpoint 1] 09:37:28.876 CNTRLR » [Node 029] querying notification status for Power Management... [Endpoint 1] 09:37:30.215 SERIAL « 0x010700133a00008d5c (9 bytes) 09:37:30.215 SERIAL » [ACK] (0x06) 09:37:30.216 DRIVER « [REQ] [SendData] callback id: 58 transmit status: OK 09:37:30.333 SERIAL « 0x010c00040016064303012200d256 (14 bytes) 09:37:30.334 CNTRLR [Node 022] [~] [Thermostat Setpoint] setpoint[1]: 21 => 21 [Endpoint 0] 09:37:30.335 CNTRLR [Node 022] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 09:37:30.336 SERIAL » [ACK] (0x06) 09:37:30.337 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 21 °C 09:37:30.343 SERIAL » 0x011000131d09600d00017104000800253be7 (18 bytes) 09:37:30.344 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 59 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: Power Management 09:37:30.345 CNTRLR « [Node 022] received current value of setpoint Heating: 21 °C 09:37:30.345 CNTRLR [Node 022] [~] [Thermostat Setpoint] interviewComplete [Endpoint 0] [internal] : true => true 09:37:30.391 SERIAL « [ACK] (0x06) 09:37:30.395 SERIAL « 0x0104011301e8 (6 bytes) 09:37:30.395 SERIAL » [ACK] (0x06) 09:37:30.396 DRIVER « [RES] [SendData] was sent: true 09:37:30.399 CNTRLR [Node 022] ConfigurationCC: Loading configuration parameters from device confi g 09:37:30.408 CNTRLR [Node 022] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:37:30.409 CNTRLR [Node 022] [Configuration] 1: metadata updated 09:37:30.410 CNTRLR [Node 022] [Configuration] 2: metadata updated 09:37:30.412 CNTRLR [Node 022] [Configuration] 3: metadata updated 09:37:30.413 CNTRLR [Node 022] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:37:30.413 CNTRLR » [Node 022] querying parameter #1 value... 09:37:31.882 SERIAL « 0x010700133b00009a4a (9 bytes) 09:37:31.883 SERIAL » [ACK] (0x06) 09:37:31.884 DRIVER « [REQ] [SendData] callback id: 59 transmit status: OK 09:37:31.969 SERIAL « 0x01130004001d0d600d01007105000000ff08fe00e9 (21 bytes) 09:37:31.971 SERIAL » [ACK] (0x06) 09:37:31.972 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 09:37:31.978 SERIAL » 0x010d00131c06600d00017502253cf9 (15 bytes) 09:37:31.979 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 60 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 09:37:31.980 CNTRLR [Node 029] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 1] 54 09:37:31.981 CNTRLR » [Node 029] querying notification status for System... [Endpoint 1] 09:37:31.985 SERIAL « [ACK] (0x06) 09:37:31.987 SERIAL « 0x0104011301e8 (6 bytes) 09:37:31.988 SERIAL » [ACK] (0x06) 09:37:31.989 DRIVER « [RES] [SendData] was sent: true 09:37:33.381 SERIAL « 0x010700133c00008c5b (9 bytes) 09:37:33.381 SERIAL » [ACK] (0x06) 09:37:33.382 DRIVER « [REQ] [SendData] callback id: 60 transmit status: OK 09:37:33.497 SERIAL « 0x010d0004001c07600d0100750300f7 (15 bytes) 09:37:33.498 CNTRLR [Node 028] [~] [Protection] local: 0 => 0 [Endpoint 1] 09:37:33.499 SERIAL » [ACK] (0x06) 09:37:33.500 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ProtectionCCReport] local: Unprotected 09:37:33.504 SERIAL » 0x011000131d09600d00017104000900253de0 (18 bytes) 09:37:33.505 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 61 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: System 09:37:33.506 CNTRLR « [Node 028] received protection status: local: Unprotected 09:37:33.506 CNTRLR [Node 028] [~] [Protection] interviewComplete: true => [Endpoint 1] [internal] true 09:37:33.553 SERIAL « [ACK] (0x06) 09:37:33.555 SERIAL « 0x0104011301e8 (6 bytes) 09:37:33.555 SERIAL » [ACK] (0x06) 09:37:33.556 DRIVER « [RES] [SendData] was sent: true 09:37:33.559 CNTRLR [Node 028] BatteryCC: doing a partial interview... [Endpoint 1] 09:37:33.559 CNTRLR » [Node 028] querying battery status... [Endpoint 1] 09:37:35.028 SERIAL « 0x010c0004100306310504220a3bc1 (14 bytes) 09:37:35.029 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:35.030 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 121 => 261.9 [Endpoint 0] 09:37:35.031 SERIAL » [ACK] (0x06) 09:37:35.032 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 261.9 09:37:35.052 SERIAL « 0x010700133d00009b4d (9 bytes) 09:37:35.053 SERIAL » [ACK] (0x06) 09:37:35.053 DRIVER « [REQ] [SendData] callback id: 61 transmit status: OK 09:37:35.094 SERIAL « 0x010c0004100306310504220a3bc1 (14 bytes) 09:37:35.095 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:35.095 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 261.9 => 261.9 [Endpoint 0] 09:37:35.096 SERIAL » [ACK] (0x06) 09:37:35.097 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 261.9 09:37:35.141 SERIAL « 0x01130004001d0d600d01007105000000ff09fe00e8 (21 bytes) 09:37:35.142 SERIAL » [ACK] (0x06) 09:37:35.143 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: System notification status: 255 notification event: Unknown (0xfe) 09:37:35.145 SERIAL » 0x010a0013180370050d253e9e (12 bytes) 09:37:35.146 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 62 └─[ConfigurationCCGet] parameter #: 13 09:37:35.147 CNTRLR [Node 029] [~] [Notification] System[unknown]: 254 => 254 [Endpoint 1] 09:37:35.147 CNTRLR [Node 029] [~] [Notification] interviewComplete: true [Endpoint 1] [internal] => true 09:37:35.175 SERIAL « 0x010c0004100306310504220a3bc1 (14 bytes) 09:37:35.176 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:35.176 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 261.9 => 261.9 [Endpoint 0] 09:37:35.177 SERIAL » [ACK] (0x06) 09:37:35.177 SERIAL « [CAN] (0x18) 09:37:35.178 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 09:37:35.182 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 261.9 09:37:35.185 SERIAL « 0x010c0004100306310504220a3bc1 (14 bytes) 09:37:35.186 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:35.186 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 261.9 => 261.9 [Endpoint 0] 09:37:35.186 SERIAL » [ACK] (0x06) 09:37:35.187 CNTRLR [Node 029] ProtectionCC: doing a partial interview... 09:37:35.188 CNTRLR » [Node 029] querying protection status... 09:37:35.190 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 261.9 09:37:35.279 SERIAL » 0x010a0013180370050d253e9e (12 bytes) 09:37:35.294 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 62 └─[ConfigurationCCGet] parameter #: 13 09:37:35.295 SERIAL « 0x010c0004100306310504220a3bc1 (14 bytes) 09:37:35.296 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:35.297 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 261.9 => 261.9 [Endpoint 0] 09:37:35.298 SERIAL » [ACK] (0x06) 09:37:35.300 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 261.9 09:37:35.301 SERIAL « [CAN] (0x18) 09:37:35.302 CNTRLR No response from controller after 2/3 attempts. Scheduling next try in 1100 ms . 09:37:35.434 SERIAL « 0x010c0004100306310504220a3bc1 (14 bytes) 09:37:35.435 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:35.435 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 261.9 => 261.9 [Endpoint 0] 09:37:35.436 SERIAL » [ACK] (0x06) 09:37:35.437 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 261.9 09:37:35.591 SERIAL « 0x010c0004100306310504220a3bc1 (14 bytes) 09:37:35.592 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:35.593 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 261.9 => 261.9 [Endpoint 0] 09:37:35.593 SERIAL » [ACK] (0x06) 09:37:35.594 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 261.9 09:37:35.828 SERIAL « 0x010c0004100306310504220a3bc1 (14 bytes) 09:37:35.829 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:35.829 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 261.9 => 261.9 [Endpoint 0] 09:37:35.830 SERIAL » [ACK] (0x06) 09:37:35.831 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 261.9 09:37:36.403 SERIAL » 0x010a0013180370050d253e9e (12 bytes) 09:37:36.404 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 62 └─[ConfigurationCCGet] parameter #: 13 09:37:36.405 SERIAL « [ACK] (0x06) 09:37:36.412 SERIAL « 0x0104011301e8 (6 bytes) 09:37:36.412 SERIAL » [ACK] (0x06) 09:37:36.413 DRIVER « [RES] [SendData] was sent: true 09:37:36.433 SERIAL « 0x010700133e000003d6 (9 bytes) 09:37:36.433 SERIAL » [ACK] (0x06) 09:37:36.433 DRIVER « [REQ] [SendData] callback id: 62 transmit status: OK 09:37:36.447 SERIAL « 0x010c000400180670060d02000595 (14 bytes) 09:37:36.455 CNTRLR [Node 024] [~] [Configuration] 13: 5 => 5 09:37:36.457 SERIAL » [ACK] (0x06) 09:37:36.458 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 2 value: 5 09:37:36.463 SERIAL » 0x010d00131d06600d00017502253ffb (15 bytes) 09:37:36.464 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 63 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 09:37:36.464 CNTRLR « [Node 024] parameter #13 has value: 5 09:37:36.465 CNTRLR » [Node 024] querying parameter #15 value... 09:37:36.470 SERIAL « [ACK] (0x06) 09:37:36.472 SERIAL « 0x0104011301e8 (6 bytes) 09:37:36.473 SERIAL » [ACK] (0x06) 09:37:36.474 DRIVER « [RES] [SendData] was sent: true 09:37:36.556 SERIAL « 0x010700133f000009dd (9 bytes) 09:37:36.556 SERIAL » [ACK] (0x06) 09:37:36.557 DRIVER « [REQ] [SendData] callback id: 63 transmit status: OK 09:37:38.159 CNTRLR [Node 029] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:37:38.662 SERIAL » 0x010d00131d06600d00017502253ffb (15 bytes) 09:37:38.662 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 63 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 09:37:38.664 SERIAL « [ACK] (0x06) 09:37:38.670 SERIAL « 0x0104011301e8 (6 bytes) 09:37:38.671 SERIAL » [ACK] (0x06) 09:37:38.671 DRIVER « [RES] [SendData] was sent: true 09:37:38.754 SERIAL « 0x010700133f000009dd (9 bytes) 09:37:38.755 SERIAL » [ACK] (0x06) 09:37:38.755 DRIVER « [REQ] [SendData] callback id: 63 transmit status: OK 09:37:38.839 SERIAL « 0x010d0004001d07600d0100750300f6 (15 bytes) 09:37:38.840 CNTRLR [Node 029] [~] [Protection] local: 0 => 0 [Endpoint 1] 09:37:38.840 SERIAL » [ACK] (0x06) 09:37:38.841 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ProtectionCCReport] local: Unprotected 09:37:38.844 SERIAL » 0x010a00131a0370051e2540f1 (12 bytes) 09:37:38.844 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 64 └─[ConfigurationCCGet] parameter #: 30 09:37:38.845 CNTRLR « [Node 029] received protection status: local: Unprotected 09:37:38.845 CNTRLR [Node 029] [~] [Protection] interviewComplete: true => [Endpoint 1] [internal] true 09:37:38.871 SERIAL « [ACK] (0x06) 09:37:38.872 SERIAL « 0x0104011301e8 (6 bytes) 09:37:38.873 SERIAL » [ACK] (0x06) 09:37:38.875 DRIVER « [RES] [SendData] was sent: true 09:37:38.878 CNTRLR [Node 029] BatteryCC: doing a partial interview... [Endpoint 1] 09:37:38.878 CNTRLR » [Node 029] querying battery status... [Endpoint 1] 09:37:38.927 SERIAL « 0x0107001340000008a3 (9 bytes) 09:37:38.928 SERIAL » [ACK] (0x06) 09:37:38.928 DRIVER « [REQ] [SendData] callback id: 64 transmit status: OK 09:37:38.938 SERIAL « 0x010b0004001a0570061e010284 (13 bytes) 09:37:38.943 CNTRLR [Node 026] [~] [Configuration] 30: 2 => 2 09:37:38.944 SERIAL » [ACK] (0x06) 09:37:38.944 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 2 09:37:38.947 SERIAL » 0x010d00131d06600d00018002254170 (15 bytes) 09:37:38.948 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 65 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BatteryCCGet] 09:37:38.948 CNTRLR « [Node 026] parameter #30 has value: 2 09:37:38.948 CNTRLR » [Node 026] querying parameter #31 value... 09:37:38.951 SERIAL « [ACK] (0x06) 09:37:38.956 SERIAL « 0x0104011301e8 (6 bytes) 09:37:38.956 SERIAL » [ACK] (0x06) 09:37:38.957 DRIVER « [RES] [SendData] was sent: true 09:37:39.040 SERIAL « 0x0107001341000009a3 (9 bytes) 09:37:39.040 SERIAL » [ACK] (0x06) 09:37:39.041 DRIVER « [REQ] [SendData] callback id: 65 transmit status: OK 09:37:39.129 SERIAL « 0x010d0004001d07600d010080036360 (15 bytes) 09:37:39.131 CNTRLR [Node 029] [~] [Battery] level: 99 => 99 [Endpoint 1] 09:37:39.132 CNTRLR [Node 029] [~] [Battery] isLow: false => false [Endpoint 1] 09:37:39.132 SERIAL » [ACK] (0x06) 09:37:39.134 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BatteryCCReport] level: 99 is low: false 09:37:39.154 SERIAL » 0x010900130602984025425e (11 bytes) 09:37:39.154 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 66 └─[SecurityCCNonceGet] 09:37:39.155 CNTRLR « [Node 029] received response for battery information: [Endpoint 1] level: 99 09:37:39.156 CNTRLR [Node 029] [~] [Battery] interviewComplete: true => tr [Endpoint 1] [internal] ue 09:37:39.203 SERIAL « [ACK] (0x06) 09:37:39.208 SERIAL « 0x0104011301e8 (6 bytes) 09:37:39.208 SERIAL » [ACK] (0x06) 09:37:39.209 DRIVER « [RES] [SendData] was sent: true 09:37:39.213 CNTRLR [Node 029] ClockCC: doing a partial interview... 09:37:39.213 CNTRLR » [Node 029] requesting current clock setting... 09:37:40.496 SERIAL « 0x01070013420000862f (9 bytes) 09:37:40.496 SERIAL » [ACK] (0x06) 09:37:40.497 DRIVER « [REQ] [SendData] callback id: 66 transmit status: OK 09:37:40.518 SERIAL « 0x0110000400060a9880355870b9835bce7835 (18 bytes) 09:37:40.519 SERIAL » [ACK] (0x06) 09:37:40.520 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x355870b9835bce78 09:37:40.527 SERIAL » 0x01240013061d988126fe8bb428e602ee303dcd959cd8ba19545f35ba8bb507ea5 (38 bytes) 254f725437d 09:37:40.528 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 67 └─[SecurityCCCommandEncapsulation] │ nonce id: 53 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:37:40.531 SERIAL « [ACK] (0x06) 09:37:40.538 SERIAL « 0x0104011301e8 (6 bytes) 09:37:40.539 SERIAL » [ACK] (0x06) 09:37:40.540 DRIVER « [RES] [SendData] was sent: true 09:37:40.564 SERIAL « 0x0107001343000003ab (9 bytes) 09:37:40.565 SERIAL » [ACK] (0x06) 09:37:40.566 DRIVER « [REQ] [SendData] callback id: 67 transmit status: OK 09:37:42.169 CNTRLR [Node 006] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:37:42.674 SERIAL » 0x0109001306029840254458 (11 bytes) 09:37:42.674 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 68 └─[SecurityCCNonceGet] 09:37:42.676 SERIAL « [ACK] (0x06) 09:37:42.682 SERIAL « 0x0104011301e8 (6 bytes) 09:37:42.682 SERIAL » [ACK] (0x06) 09:37:42.683 DRIVER « [RES] [SendData] was sent: true 09:37:43.902 SERIAL « 0x010700134400007bd4 (9 bytes) 09:37:43.903 SERIAL » [ACK] (0x06) 09:37:43.904 DRIVER « [REQ] [SendData] callback id: 68 transmit status: OK 09:37:43.925 SERIAL « 0x0110000400060a9880ae186044c7506d9e09 (18 bytes) 09:37:43.926 SERIAL » [ACK] (0x06) 09:37:43.927 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xae186044c7506d9e 09:37:43.933 SERIAL » 0x01240013061d9881ccb55431c812f1ebed821e3623b5171b1d2aae6f8b111a48e (38 bytes) eef2b2543b9 09:37:43.934 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 67 └─[SecurityCCCommandEncapsulation] │ nonce id: 174 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:37:43.938 SERIAL « [ACK] (0x06) 09:37:43.945 SERIAL « 0x0104011301e8 (6 bytes) 09:37:43.945 SERIAL » [ACK] (0x06) 09:37:43.946 DRIVER « [RES] [SendData] was sent: true 09:37:43.971 SERIAL « 0x0107001343000003ab (9 bytes) 09:37:43.971 SERIAL » [ACK] (0x06) 09:37:43.973 DRIVER « [REQ] [SendData] callback id: 67 transmit status: OK 09:37:44.325 SERIAL « 0x010c00040003063105042209779e (14 bytes) 09:37:44.326 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:44.327 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 261.9 => 242.3 [Endpoint 0] 09:37:44.328 SERIAL » [ACK] (0x06) 09:37:44.330 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 242.3 09:37:45.316 SERIAL « 0x010c00040003063105042206e503 (14 bytes) 09:37:45.317 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:45.317 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 242.3 => 176.5 [Endpoint 0] 09:37:45.318 SERIAL » [ACK] (0x06) 09:37:45.319 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 176.5 09:37:45.577 CNTRLR [Node 006] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:37:46.086 SERIAL » 0x0109001306029840254559 (11 bytes) 09:37:46.086 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 69 └─[SecurityCCNonceGet] 09:37:46.088 SERIAL « [ACK] (0x06) 09:37:46.094 SERIAL « 0x0104011301e8 (6 bytes) 09:37:46.095 SERIAL » [ACK] (0x06) 09:37:46.096 DRIVER « [RES] [SendData] was sent: true 09:37:47.357 SERIAL « 0x010c00040003063105042207ee09 (14 bytes) 09:37:47.358 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:47.359 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 176.5 => 203 [Endpoint 0] 09:37:47.360 SERIAL » [ACK] (0x06) 09:37:47.362 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 203 09:37:47.366 SERIAL « 0x010700134500007fd1 (9 bytes) 09:37:47.366 SERIAL » [ACK] (0x06) 09:37:47.367 DRIVER « [REQ] [SendData] callback id: 69 transmit status: OK 09:37:47.446 SERIAL « 0x0110000400060a98807c9711896773176ee1 (18 bytes) 09:37:47.447 SERIAL » [ACK] (0x06) 09:37:47.448 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x7c9711896773176e 09:37:47.461 SERIAL » 0x01240013061d988180784327e0842b56bf19a45c0bdf2b2e844b7c70db423e27f (38 bytes) cd9632543a3 09:37:47.483 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 67 └─[SecurityCCCommandEncapsulation] │ nonce id: 124 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:37:47.486 SERIAL « [ACK] (0x06) 09:37:47.494 SERIAL « 0x0104011301e8 (6 bytes) 09:37:47.494 SERIAL » [ACK] (0x06) 09:37:47.495 DRIVER « [RES] [SendData] was sent: true 09:37:47.519 SERIAL « 0x0107001343000003ab (9 bytes) 09:37:47.520 SERIAL » [ACK] (0x06) 09:37:47.521 DRIVER « [REQ] [SendData] callback id: 67 transmit status: OK 09:37:48.316 SERIAL « 0x010c0004000306310504220556b3 (14 bytes) 09:37:48.317 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:37:48.318 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 203 => 136.6 [Endpoint 0] 09:37:48.319 SERIAL » [ACK] (0x06) 09:37:48.321 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 136.6 09:37:49.128 SERIAL » 0x010d00131d06600d00018105254671 (15 bytes) 09:37:49.129 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 70 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ClockCCGet] 09:37:49.130 CNTRLR [Node 006] Interview attempt 4/5 failed, retrying in 20000 ms... 09:37:49.131 SERIAL « [ACK] (0x06) 09:37:49.138 SERIAL « 0x0104011301e8 (6 bytes) 09:37:49.138 SERIAL » [ACK] (0x06) 09:37:49.139 DRIVER « [RES] [SendData] was sent: true 09:37:50.625 SERIAL « 0x010700134600009538 (9 bytes) 09:37:50.625 SERIAL » [ACK] (0x06) 09:37:50.626 DRIVER « [REQ] [SendData] callback id: 70 transmit status: OK 09:37:50.742 SERIAL « 0x010e0004001d08600d01008106e926c4 (16 bytes) 09:37:50.743 SERIAL » [ACK] (0x06) 09:37:50.744 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ClockCCReport] clock setting: Sunday, 09:38 09:37:50.749 SERIAL » 0x010a001316037005012547e5 (12 bytes) 09:37:50.750 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 71 └─[ConfigurationCCGet] parameter #: 1 09:37:50.751 CNTRLR « [Node 029] received current clock setting: Sunday, 09:38 09:37:50.751 CNTRLR [Node 029] [~] [Clock] interviewComplete: true => true [Endpoint 1] [internal] 09:37:50.807 SERIAL « [ACK] (0x06) 09:37:50.812 SERIAL « 0x0104011301e8 (6 bytes) 09:37:50.813 SERIAL » [ACK] (0x06) 09:37:50.814 DRIVER « [RES] [SendData] was sent: true 09:37:50.820 CNTRLR [Node 029] ZWavePlusCC: doing a partial interview... [Endpoint 2] 09:37:50.821 CNTRLR [Node 029] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 09:37:50.822 CNTRLR [Node 029] MultilevelSensorCC: doing a partial interview... [Endpoint 2] 09:37:50.822 CNTRLR » [Node 029] querying Air temperature sensor reading... [Endpoint 2] 09:37:52.165 SERIAL « 0x010700134700008d21 (9 bytes) 09:37:52.166 SERIAL » [ACK] (0x06) 09:37:52.167 DRIVER « [REQ] [SendData] callback id: 71 transmit status: OK 09:37:52.286 SERIAL « 0x010e000400160870060104000000f068 (16 bytes) 09:37:52.299 CNTRLR [Node 022] [~] [Configuration] 1: 240 => 240 09:37:52.301 SERIAL » [ACK] (0x06) 09:37:52.302 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 4 value: 240 09:37:52.308 SERIAL » 0x010f00131d08600d0002310401002548c0 (17 bytes) 09:37:52.309 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 72 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:37:52.309 CNTRLR « [Node 022] parameter #1 has value: 240 09:37:52.310 CNTRLR » [Node 022] querying parameter #2 value... 09:37:52.315 SERIAL « [ACK] (0x06) 09:37:52.318 SERIAL « 0x0104011301e8 (6 bytes) 09:37:52.319 SERIAL » [ACK] (0x06) 09:37:52.319 DRIVER « [RES] [SendData] was sent: true 09:37:53.849 SERIAL « 0x01070013480000993a (9 bytes) 09:37:53.849 SERIAL » [ACK] (0x06) 09:37:53.850 DRIVER « [REQ] [SendData] callback id: 72 transmit status: OK 09:37:53.972 SERIAL « 0x01100004001d0a600d02003105012200c044 (18 bytes) 09:37:53.974 CNTRLR [Node 029] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:37:53.976 CNTRLR [Node 029] [~] [Multilevel Sensor] Air temperature: 18.7 => 19.2 [Endpoint 2] 09:37:53.977 SERIAL » [ACK] (0x06) 09:37:53.981 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 19.2 09:37:53.988 SERIAL » 0x010d00131c06600d00018002254979 (15 bytes) 09:37:53.988 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 73 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BatteryCCGet] 09:37:53.989 CNTRLR « [Node 029] received current Air temperature sensor reading: 19.2 [Endpoint 2] °C 09:37:53.990 CNTRLR [Node 029] [~] [Multilevel Sensor] interviewComplete: [Endpoint 2] [internal] true => true 09:37:54.062 SERIAL « [ACK] (0x06) 09:37:54.063 SERIAL « 0x0104011301e8 (6 bytes) 09:37:54.063 SERIAL » [ACK] (0x06) 09:37:54.064 DRIVER « [RES] [SendData] was sent: true 09:37:54.199 CNTRLR [Node 029] NotificationCC: doing a partial interview... [Endpoint 2] 09:37:54.200 CNTRLR » [Node 029] querying notification status for Power Management... [Endpoint 2] 09:37:55.452 SERIAL « 0x010700134900009230 (9 bytes) 09:37:55.452 SERIAL » [ACK] (0x06) 09:37:55.454 DRIVER « [REQ] [SendData] callback id: 73 transmit status: OK 09:37:55.538 SERIAL « 0x010d0004001c07600d010080036466 (15 bytes) 09:37:55.539 CNTRLR [Node 028] [~] [Battery] level: 100 => 100 [Endpoint 1] 09:37:55.540 CNTRLR [Node 028] [~] [Battery] isLow: false => false [Endpoint 1] 09:37:55.541 SERIAL » [ACK] (0x06) 09:37:55.542 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BatteryCCReport] level: 100 is low: false 09:37:55.548 SERIAL » 0x011000131d09600d00027104000800254a95 (18 bytes) 09:37:55.548 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 74 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: Power Management 09:37:55.549 CNTRLR « [Node 028] received response for battery information: [Endpoint 1] level: 100 09:37:55.550 CNTRLR [Node 028] [~] [Battery] interviewComplete: true => tr [Endpoint 1] [internal] ue 09:37:55.600 SERIAL « [ACK] (0x06) 09:37:55.601 SERIAL « 0x0104011301e8 (6 bytes) 09:37:55.601 SERIAL » [ACK] (0x06) 09:37:55.605 DRIVER « [RES] [SendData] was sent: true 09:37:55.608 CNTRLR [Node 028] ClockCC: doing a partial interview... 09:37:55.609 CNTRLR » [Node 028] requesting current clock setting... 09:37:57.118 SERIAL « 0x010700134a00009c3d (9 bytes) 09:37:57.118 SERIAL » [ACK] (0x06) 09:37:57.119 DRIVER « [REQ] [SendData] callback id: 74 transmit status: OK 09:37:57.209 SERIAL « 0x01130004001d0d600d02007105000000ff08fe00ea (21 bytes) 09:37:57.210 SERIAL » [ACK] (0x06) 09:37:57.211 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 09:37:57.217 SERIAL » 0x010a0013180370050f254be9 (12 bytes) 09:37:57.218 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 75 └─[ConfigurationCCGet] parameter #: 15 09:37:57.219 CNTRLR [Node 029] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 2] 54 09:37:57.221 CNTRLR » [Node 029] querying notification status for System... [Endpoint 2] 09:37:57.226 SERIAL « [ACK] (0x06) 09:37:57.228 SERIAL « 0x0104011301e8 (6 bytes) 09:37:57.229 SERIAL » [ACK] (0x06) 09:37:57.230 DRIVER « [RES] [SendData] was sent: true 09:37:57.301 SERIAL « 0x010700134b000008a8 (9 bytes) 09:37:57.302 SERIAL » [ACK] (0x06) 09:37:57.302 DRIVER « [REQ] [SendData] callback id: 75 transmit status: OK 09:37:57.315 SERIAL « 0x010b000400180570060f010095 (13 bytes) 09:37:57.325 CNTRLR [Node 024] [~] [Configuration] 15: 0 => 0 09:37:57.327 SERIAL » [ACK] (0x06) 09:37:57.328 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 15 value size: 1 value: 0 09:37:57.334 SERIAL » 0x011000131d09600d00027104000900254c92 (18 bytes) 09:37:57.335 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 76 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:37:57.335 CNTRLR « [Node 024] parameter #15 has value: 0 09:37:57.336 CNTRLR » [Node 024] querying parameter #16 value... 09:37:57.340 SERIAL « [ACK] (0x06) 09:37:57.343 SERIAL « 0x0104011301e8 (6 bytes) 09:37:57.344 SERIAL » [ACK] (0x06) 09:37:57.345 DRIVER « [RES] [SendData] was sent: true 09:37:57.429 SERIAL « 0x010700134c000009ae (9 bytes) 09:37:57.429 SERIAL » [ACK] (0x06) 09:37:57.430 DRIVER « [REQ] [SendData] callback id: 76 transmit status: OK 09:37:59.037 CNTRLR [Node 029] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:37:59.542 SERIAL » 0x011000131d09600d00027104000900254c92 (18 bytes) 09:37:59.543 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 76 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:37:59.546 SERIAL « [ACK] (0x06) 09:37:59.553 SERIAL « 0x0104011301e8 (6 bytes) 09:37:59.553 SERIAL » [ACK] (0x06) 09:37:59.554 DRIVER « [RES] [SendData] was sent: true 09:38:01.043 SERIAL « 0x010700134c00009631 (9 bytes) 09:38:01.044 SERIAL » [ACK] (0x06) 09:38:01.045 DRIVER « [REQ] [SendData] callback id: 76 transmit status: OK 09:38:02.650 CNTRLR [Node 029] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:38:03.153 SERIAL » 0x011000131d09600d00027104000900254c92 (18 bytes) 09:38:03.154 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 76 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:38:03.157 SERIAL « [ACK] (0x06) 09:38:03.162 SERIAL « 0x0104011301e8 (6 bytes) 09:38:03.163 SERIAL » [ACK] (0x06) 09:38:03.163 DRIVER « [RES] [SendData] was sent: true 09:38:04.670 SERIAL « 0x010700134c00009730 (9 bytes) 09:38:04.671 SERIAL » [ACK] (0x06) 09:38:04.672 DRIVER « [REQ] [SendData] callback id: 76 transmit status: OK 09:38:06.278 SERIAL » 0x010a00131a0370051f254dfd (12 bytes) 09:38:06.279 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 77 └─[ConfigurationCCGet] parameter #: 31 09:38:06.279 CNTRLR [Node 029] Interview attempt 3/5 failed, retrying in 15000 ms... 09:38:06.280 SERIAL « [ACK] (0x06) 09:38:06.287 SERIAL « 0x0104011301e8 (6 bytes) 09:38:06.287 SERIAL » [ACK] (0x06) 09:38:06.288 DRIVER « [RES] [SendData] was sent: true 09:38:06.305 SERIAL « 0x010700134d000002a4 (9 bytes) 09:38:06.305 SERIAL » [ACK] (0x06) 09:38:06.305 DRIVER « [REQ] [SendData] callback id: 77 transmit status: OK 09:38:06.316 SERIAL « 0x010b0004001a0570061f010087 (13 bytes) 09:38:06.321 CNTRLR [Node 026] [~] [Configuration] 31: 0 => 0 09:38:06.322 SERIAL » [ACK] (0x06) 09:38:06.322 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 0 09:38:06.325 SERIAL » 0x010a00131603700502254eef (12 bytes) 09:38:06.325 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 78 └─[ConfigurationCCGet] parameter #: 2 09:38:06.326 CNTRLR « [Node 026] parameter #31 has value: 0 09:38:06.326 CNTRLR » [Node 026] querying parameter #32 value... 09:38:06.343 SERIAL « [ACK] (0x06) 09:38:06.344 SERIAL « 0x0104011301e8 (6 bytes) 09:38:06.344 SERIAL » [ACK] (0x06) 09:38:06.345 DRIVER « [RES] [SendData] was sent: true 09:38:07.694 SERIAL « 0x010700134e0000892c (9 bytes) 09:38:07.694 SERIAL » [ACK] (0x06) 09:38:07.695 DRIVER « [REQ] [SendData] callback id: 78 transmit status: OK 09:38:07.877 SERIAL « 0x010900040008032001ff27 (11 bytes) 09:38:07.879 SERIAL » [ACK] (0x06) 09:38:07.880 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:38:07.883 CNTRLR [Node 008] treating BasicCC Set as a report 09:38:07.885 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:38:09.131 CNTRLR [Node 006] Beginning interview - last completed stage: RestartFromCache 09:38:09.132 CNTRLR » [Node 006] pinging the node... 09:38:09.300 CNTRLR [Node 022] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:38:09.805 SERIAL » 0x010a00131603700502254eef (12 bytes) 09:38:09.806 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 78 └─[ConfigurationCCGet] parameter #: 2 09:38:09.808 SERIAL « [ACK] (0x06) 09:38:09.815 SERIAL « 0x0104011301e8 (6 bytes) 09:38:09.815 SERIAL » [ACK] (0x06) 09:38:09.816 DRIVER « [RES] [SendData] was sent: true 09:38:09.871 SERIAL « 0x010700134e000006a3 (9 bytes) 09:38:09.871 SERIAL » [ACK] (0x06) 09:38:09.872 DRIVER « [REQ] [SendData] callback id: 78 transmit status: OK 09:38:09.953 SERIAL « 0x010e000400160870060204000000019a (16 bytes) 09:38:09.970 CNTRLR [Node 022] [~] [Configuration] 2: 1 => 1 09:38:09.972 SERIAL » [ACK] (0x06) 09:38:09.974 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 4 value: 1 09:38:09.982 SERIAL » 0x01080013060100254f89 (10 bytes) 09:38:09.984 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 79 └─[NoOperationCC] 09:38:09.985 CNTRLR « [Node 022] parameter #2 has value: 1 09:38:09.985 CNTRLR » [Node 022] querying parameter #3 value... 09:38:09.994 SERIAL « [ACK] (0x06) 09:38:09.996 SERIAL « 0x0104011301e8 (6 bytes) 09:38:09.997 SERIAL » [ACK] (0x06) 09:38:09.998 DRIVER « [RES] [SendData] was sent: true 09:38:11.300 SERIAL « 0x010700134f00008327 (9 bytes) 09:38:11.301 SERIAL » [ACK] (0x06) 09:38:11.301 DRIVER « [REQ] [SendData] callback id: 79 transmit status: OK 09:38:11.323 SERIAL » 0x010d00131c06600d00018105255066 (15 bytes) 09:38:11.324 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 80 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ClockCCGet] 09:38:11.325 CNTRLR « [Node 006] ping successful 09:38:11.398 SERIAL « [ACK] (0x06) 09:38:11.403 SERIAL « 0x0104011301e8 (6 bytes) 09:38:11.404 SERIAL » [ACK] (0x06) 09:38:11.405 DRIVER « [RES] [SendData] was sent: true 09:38:11.413 CNTRLR [Node 006] ManufacturerSpecificCC: doing a partial interview... 09:38:11.414 CNTRLR [Node 006] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:38:11.415 CNTRLR [Node 006] VersionCC: doing a partial interview... 09:38:11.415 CNTRLR [Node 006] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:38:11.415 CNTRLR [Node 006] trying to load device config 09:38:11.419 CNTRLR [Node 006] device config loaded 09:38:11.419 CNTRLR [Node 006] ZWavePlusCC: doing a partial interview... 09:38:11.420 CNTRLR [Node 006] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:38:11.420 CNTRLR » [Node 006] querying device endpoint information... 09:38:12.711 SERIAL « 0x010700135000008a31 (9 bytes) 09:38:12.711 SERIAL » [ACK] (0x06) 09:38:12.711 DRIVER « [REQ] [SendData] callback id: 80 transmit status: OK 09:38:12.826 SERIAL « 0x010e0004001c08600d01008106e920c3 (16 bytes) 09:38:12.827 SERIAL » [ACK] (0x06) 09:38:12.827 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ClockCCReport] clock setting: Sunday, 09:32 09:38:12.830 SERIAL » 0x010a001318037005102551ec (12 bytes) 09:38:12.831 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 81 └─[ConfigurationCCGet] parameter #: 16 09:38:12.831 CNTRLR « [Node 028] received current clock setting: Sunday, 09:32 09:38:12.833 CNTRLR [Node 028] [~] [Clock] interviewComplete: true => true [Endpoint 1] [internal] 09:38:12.912 SERIAL « [ACK] (0x06) 09:38:12.919 SERIAL « 0x0104011301e8 (6 bytes) 09:38:12.920 SERIAL » [ACK] (0x06) 09:38:12.923 DRIVER « [RES] [SendData] was sent: true 09:38:12.930 CNTRLR [Node 028] ZWavePlusCC: doing a partial interview... [Endpoint 2] 09:38:12.931 CNTRLR [Node 028] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 09:38:12.932 CNTRLR [Node 028] MultilevelSensorCC: doing a partial interview... [Endpoint 2] 09:38:12.933 CNTRLR » [Node 028] querying Air temperature sensor reading... [Endpoint 2] 09:38:12.939 SERIAL « 0x0107001351000009b3 (9 bytes) 09:38:12.939 SERIAL » [ACK] (0x06) 09:38:12.940 DRIVER « [REQ] [SendData] callback id: 81 transmit status: OK 09:38:12.942 SERIAL « 0x010b000400180570061001008a (13 bytes) 09:38:12.948 CNTRLR [Node 024] [~] [Configuration] 16: 0 => 0 09:38:12.949 SERIAL » [ACK] (0x06) 09:38:12.950 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 0 09:38:12.955 SERIAL » 0x010a00131a037005202552dd (12 bytes) 09:38:12.955 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 82 └─[ConfigurationCCGet] parameter #: 32 09:38:12.956 CNTRLR « [Node 024] parameter #16 has value: 0 09:38:12.956 CNTRLR » [Node 024] querying parameter #17 value... 09:38:12.962 SERIAL « [ACK] (0x06) 09:38:12.964 SERIAL « 0x0104011301e8 (6 bytes) 09:38:12.964 SERIAL » [ACK] (0x06) 09:38:12.965 DRIVER « [RES] [SendData] was sent: true 09:38:12.981 SERIAL « 0x0107001352000003ba (9 bytes) 09:38:12.981 SERIAL » [ACK] (0x06) 09:38:12.982 DRIVER « [REQ] [SendData] callback id: 82 transmit status: OK 09:38:12.991 SERIAL « 0x010b0004001a057006200101b9 (13 bytes) 09:38:12.996 CNTRLR [Node 026] [~] [Configuration] 32: 1 => 1 09:38:12.997 SERIAL » [ACK] (0x06) 09:38:12.998 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 1 value: 1 09:38:13.000 SERIAL » 0x010a001316037005032553f3 (12 bytes) 09:38:13.001 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 83 └─[ConfigurationCCGet] parameter #: 3 09:38:13.001 CNTRLR « [Node 026] parameter #32 has value: 1 09:38:13.001 CNTRLR » [Node 026] querying parameter #33 value... 09:38:13.006 SERIAL « [ACK] (0x06) 09:38:13.010 SERIAL « 0x0104011301e8 (6 bytes) 09:38:13.010 SERIAL » [ACK] (0x06) 09:38:13.011 DRIVER « [RES] [SendData] was sent: true 09:38:14.398 SERIAL « 0x010700135300008b33 (9 bytes) 09:38:14.399 SERIAL » [ACK] (0x06) 09:38:14.399 DRIVER « [REQ] [SendData] callback id: 83 transmit status: OK 09:38:14.522 SERIAL « 0x010e000400160870060304000000019b (16 bytes) 09:38:14.534 CNTRLR [Node 022] [~] [Configuration] 3: 1 => 1 09:38:14.537 SERIAL » [ACK] (0x06) 09:38:14.538 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 4 value: 1 09:38:14.547 SERIAL » 0x0109001306029840255448 (11 bytes) 09:38:14.548 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 84 └─[SecurityCCNonceGet] 09:38:14.549 CNTRLR « [Node 022] parameter #3 has value: 1 09:38:14.549 CNTRLR [Node 022] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 09:38:14.616 SERIAL « [ACK] (0x06) 09:38:14.617 SERIAL « 0x0104011301e8 (6 bytes) 09:38:14.617 SERIAL » [ACK] (0x06) 09:38:14.620 DRIVER « [RES] [SendData] was sent: true 09:38:14.623 CNTRLR [Node 022] ProtectionCC: doing a partial interview... 09:38:14.623 CNTRLR » [Node 022] querying protection status... 09:38:15.826 SERIAL « 0x01070013540000803f (9 bytes) 09:38:15.827 SERIAL » [ACK] (0x06) 09:38:15.828 DRIVER « [REQ] [SendData] callback id: 84 transmit status: OK 09:38:15.848 SERIAL « 0x0110000400060a98807a2af128dd069ce5d4 (18 bytes) 09:38:15.849 SERIAL » [ACK] (0x06) 09:38:15.851 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x7a2af128dd069ce5 09:38:15.857 SERIAL » 0x011d001306169881fa7748c96962448a0c72857a1fc270af86c6305b2555e9 (31 bytes) 09:38:15.858 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 85 └─[SecurityCCCommandEncapsulation] │ nonce id: 122 └─[MultiChannelCCEndPointGet] 09:38:15.861 SERIAL « [ACK] (0x06) 09:38:15.868 SERIAL « 0x0104011301e8 (6 bytes) 09:38:15.868 SERIAL » [ACK] (0x06) 09:38:15.869 DRIVER « [RES] [SendData] was sent: true 09:38:15.892 SERIAL « 0x0107001355000003bd (9 bytes) 09:38:15.893 SERIAL » [ACK] (0x06) 09:38:15.894 DRIVER « [REQ] [SendData] callback id: 85 transmit status: OK 09:38:15.914 SERIAL « 0x0108000400060298402f (10 bytes) 09:38:15.914 SERIAL » [ACK] (0x06) 09:38:15.916 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:38:15.923 SERIAL » 0x01110013060a988041306b7a0dce121124006d (19 bytes) 09:38:15.924 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x41306b7a0dce1211 09:38:15.926 SERIAL « [ACK] (0x06) 09:38:15.933 SERIAL « 0x0104011301e8 (6 bytes) 09:38:15.933 SERIAL » [ACK] (0x06) 09:38:15.934 DRIVER « [RES] [SendData] was sent: true 09:38:15.975 SERIAL « 0x011f00040006199881b97eaf4b3a2e33a332b121ce2cd14120f1597b76a74e6b9 (33 bytes) 2 09:38:15.977 SERIAL » [ACK] (0x06) 09:38:15.979 CNTRLR [Node 006] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:38:15.980 CNTRLR [Node 006] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 09:38:15.980 CNTRLR [Node 006] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:38:15.981 CNTRLR [Node 006] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 09:38:15.982 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:38:15.988 SERIAL » 0x010f00131c08600d0002310401002556df (17 bytes) 09:38:15.989 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 86 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:38:15.990 CNTRLR « [Node 006] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:38:15.990 CNTRLR » [Node 006] querying all endpoints... 09:38:15.996 SERIAL « [ACK] (0x06) 09:38:15.998 SERIAL « 0x0104011301e8 (6 bytes) 09:38:15.998 SERIAL » [ACK] (0x06) 09:38:16.002 DRIVER « [RES] [SendData] was sent: true 09:38:17.360 SERIAL « 0x010700135600008835 (9 bytes) 09:38:17.360 SERIAL » [ACK] (0x06) 09:38:17.361 DRIVER « [REQ] [SendData] callback id: 86 transmit status: OK 09:38:17.403 SERIAL « 0x010c0004000306310504220516f3 (14 bytes) 09:38:17.404 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:38:17.405 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 136.6 => 130.2 [Endpoint 0] 09:38:17.406 SERIAL » [ACK] (0x06) 09:38:17.408 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 130.2 09:38:17.480 SERIAL « 0x01100004001c0a600d02003105012200c84d (18 bytes) 09:38:17.481 CNTRLR [Node 028] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:38:17.483 CNTRLR [Node 028] [~] [Multilevel Sensor] Air temperature: 19.9 => 20 [Endpoint 2] 09:38:17.483 SERIAL » [ACK] (0x06) 09:38:17.485 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 20 09:38:17.490 SERIAL » 0x010a001318037005112557eb (12 bytes) 09:38:17.490 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 87 └─[ConfigurationCCGet] parameter #: 17 09:38:17.491 CNTRLR « [Node 028] received current Air temperature sensor reading: 20 °C [Endpoint 2] 09:38:17.491 CNTRLR [Node 028] [~] [Multilevel Sensor] interviewComplete: [Endpoint 2] [internal] true => true 09:38:17.547 SERIAL « [ACK] (0x06) 09:38:17.554 SERIAL « 0x0104011301e8 (6 bytes) 09:38:17.554 SERIAL » [ACK] (0x06) 09:38:17.558 DRIVER « [RES] [SendData] was sent: true 09:38:17.560 CNTRLR [Node 028] NotificationCC: doing a partial interview... [Endpoint 2] 09:38:17.561 CNTRLR [Node 028] [~] [Notification] interviewComplete: true [Endpoint 2] [internal] => true 09:38:17.562 CNTRLR [Node 028] BatteryCC: doing a partial interview... [Endpoint 2] 09:38:17.562 CNTRLR » [Node 028] querying battery status... [Endpoint 2] 09:38:17.581 SERIAL « 0x0107001357000009b5 (9 bytes) 09:38:17.582 SERIAL » [ACK] (0x06) 09:38:17.582 DRIVER « [REQ] [SendData] callback id: 87 transmit status: OK 09:38:17.595 SERIAL « 0x010c0004001806700611020032be (14 bytes) 09:38:17.600 CNTRLR [Node 024] [~] [Configuration] 17: 50 => 50 09:38:17.601 SERIAL » [ACK] (0x06) 09:38:17.602 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 17 value size: 2 value: 50 09:38:17.605 SERIAL » 0x010a00131a037005212558d6 (12 bytes) 09:38:17.605 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 88 └─[ConfigurationCCGet] parameter #: 33 09:38:17.605 CNTRLR « [Node 024] parameter #17 has value: 50 09:38:17.606 CNTRLR » [Node 024] querying parameter #18 value... 09:38:17.609 SERIAL « [ACK] (0x06) 09:38:17.614 SERIAL « 0x0104011301e8 (6 bytes) 09:38:17.614 SERIAL » [ACK] (0x06) 09:38:17.615 DRIVER « [RES] [SendData] was sent: true 09:38:17.631 SERIAL « 0x0107001358000002b1 (9 bytes) 09:38:17.631 SERIAL » [ACK] (0x06) 09:38:17.631 DRIVER « [REQ] [SendData] callback id: 88 transmit status: OK 09:38:17.641 SERIAL « 0x010b0004001a057006210101b8 (13 bytes) 09:38:17.646 CNTRLR [Node 026] [~] [Configuration] 33: 1 => 1 09:38:17.647 SERIAL » [ACK] (0x06) 09:38:17.647 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 1 value: 1 09:38:17.650 SERIAL » 0x01090013160275022559fa (11 bytes) 09:38:17.651 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 89 └─[ProtectionCCGet] 09:38:17.651 CNTRLR « [Node 026] parameter #33 has value: 1 09:38:17.651 CNTRLR » [Node 026] querying parameter #35 value... 09:38:17.654 SERIAL « [ACK] (0x06) 09:38:17.659 SERIAL « 0x0104011301e8 (6 bytes) 09:38:17.659 SERIAL » [ACK] (0x06) 09:38:17.659 DRIVER « [RES] [SendData] was sent: true 09:38:19.066 SERIAL « 0x0112000400180c600d020032022132056d0000d9 (20 bytes) 09:38:19.068 CNTRLR [Node 024] [~] [Meter] value[66049]: 109.4 => 138.9 [Endpoint 2] 09:38:19.069 CNTRLR [Node 024] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 2] 09:38:19.070 SERIAL » [ACK] (0x06) 09:38:19.071 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 138.9 time delta: 0 seconds 09:38:20.211 SERIAL « 0x01090004101b033003ff36 (11 bytes) 09:38:20.214 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:38:20.215 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:38:20.216 SERIAL » [ACK] (0x06) 09:38:20.218 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:38:20.236 SERIAL « 0x0107001359000102b1 (9 bytes) 09:38:20.236 SERIAL » [ACK] (0x06) 09:38:20.245 DRIVER « [REQ] [SendData] callback id: 89 transmit status: OK 09:38:20.329 SERIAL « 0x0109000400160375030091 (11 bytes) 09:38:20.330 CNTRLR [Node 022] [~] [Protection] local: 0 => 0 [Endpoint 0] 09:38:20.331 SERIAL » [ACK] (0x06) 09:38:20.331 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected 09:38:20.339 SERIAL » 0x0109001306029840255a46 (11 bytes) 09:38:20.340 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 90 └─[SecurityCCNonceGet] 09:38:20.340 CNTRLR « [Node 022] received protection status: local: Unprotected 09:38:20.341 CNTRLR [Node 022] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 09:38:20.392 SERIAL « [ACK] (0x06) 09:38:20.394 SERIAL « 0x0104011301e8 (6 bytes) 09:38:20.394 SERIAL » [ACK] (0x06) 09:38:20.395 DRIVER « [RES] [SendData] was sent: true 09:38:20.416 SERIAL « 0x01090004001b032001ff34 (11 bytes) 09:38:20.417 SERIAL » [ACK] (0x06) 09:38:20.418 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:38:20.419 CNTRLR [Node 027] treating BasicCC Set as a report 09:38:20.420 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:38:20.467 SERIAL « 0x0109000400160375030091 (11 bytes) 09:38:20.468 CNTRLR [Node 022] [~] [Protection] local: 0 => 0 [Endpoint 0] 09:38:20.468 SERIAL » [ACK] (0x06) 09:38:20.468 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected 09:38:20.501 SERIAL « 0x010c0004000306310504220728cf (14 bytes) 09:38:20.501 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:38:20.502 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 130.2 => 183.2 [Endpoint 0] 09:38:20.502 SERIAL » [ACK] (0x06) 09:38:20.503 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 183.2 09:38:20.612 SERIAL « 0x01090004101b033003ff36 (11 bytes) 09:38:20.613 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:38:20.613 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:38:20.613 SERIAL » [ACK] (0x06) 09:38:20.614 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:38:20.675 SERIAL « 0x0109000400160375030091 (11 bytes) 09:38:20.676 CNTRLR [Node 022] [~] [Protection] local: 0 => 0 [Endpoint 0] 09:38:20.676 SERIAL » [ACK] (0x06) 09:38:20.677 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected 09:38:21.280 CNTRLR [Node 029] Beginning interview - last completed stage: RestartFromCache 09:38:21.281 CNTRLR » [Node 029] pinging the node... 09:38:21.770 CNTRLR [Node 022] ClockCC: doing a partial interview... 09:38:21.770 CNTRLR » [Node 022] requesting current clock setting... 09:38:21.943 SERIAL « 0x01090004101b033003ff36 (11 bytes) 09:38:21.944 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:38:21.945 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:38:21.945 SERIAL » [ACK] (0x06) 09:38:21.946 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:38:23.135 SERIAL « 0x0109000400160375030091 (11 bytes) 09:38:23.137 CNTRLR [Node 022] [~] [Protection] local: 0 => 0 [Endpoint 0] 09:38:23.137 SERIAL » [ACK] (0x06) 09:38:23.138 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected 09:38:24.319 SERIAL « 0x010700135a00018d3d (9 bytes) 09:38:24.320 SERIAL » [ACK] (0x06) 09:38:24.320 DRIVER « [REQ] [SendData] callback id: 90 transmit status: OK 09:38:24.335 SERIAL « 0x0110000400060a9880355b3aac2b905a42a4 (18 bytes) 09:38:24.349 SERIAL » [ACK] (0x06) 09:38:24.351 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x355b3aac2b905a42 09:38:24.358 SERIAL » 0x011f00130618988162d626249d1c10e6bd0fbddb0235afe48bbe61ab0764255b7 (33 bytes) f 09:38:24.359 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 91 └─[SecurityCCCommandEncapsulation] │ nonce id: 53 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:38:24.361 SERIAL « 0x0110000400060a9880f527674c228f655896 (18 bytes) 09:38:24.362 SERIAL » [ACK] (0x06) 09:38:24.363 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xf527674c228f6558 09:38:24.365 SERIAL « [CAN] (0x18) 09:38:24.366 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 09:38:24.444 SERIAL « 0x0110000400060a988026b8d33f4f409c3d23 (18 bytes) 09:38:24.445 SERIAL » [ACK] (0x06) 09:38:24.445 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x26b8d33f4f409c3d 09:38:24.467 SERIAL » 0x011f00130618988162d626249d1c10e6bd0fbddb0235afe48bbe61ab0764255b7 (33 bytes) f 09:38:24.467 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 91 └─[SecurityCCCommandEncapsulation] │ nonce id: 53 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:38:24.468 SERIAL « 0x010c00040003063105042208e008 (14 bytes) 09:38:24.469 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:38:24.470 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 183.2 => 227.2 [Endpoint 0] 09:38:24.470 SERIAL » [ACK] (0x06) 09:38:24.471 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 227.2 09:38:24.473 SERIAL « [CAN] (0x18) 09:38:24.477 CNTRLR No response from controller after 2/3 attempts. Scheduling next try in 1100 ms . 09:38:25.579 SERIAL » 0x011f00130618988162d626249d1c10e6bd0fbddb0235afe48bbe61ab0764255b7 (33 bytes) f 09:38:25.580 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 91 └─[SecurityCCCommandEncapsulation] │ nonce id: 53 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:38:25.583 SERIAL « [ACK] (0x06) 09:38:25.590 SERIAL « 0x0104011301e8 (6 bytes) 09:38:25.591 SERIAL » [ACK] (0x06) 09:38:25.592 DRIVER « [RES] [SendData] was sent: true 09:38:25.615 SERIAL « 0x010700135b000003b3 (9 bytes) 09:38:25.616 SERIAL » [ACK] (0x06) 09:38:25.617 DRIVER « [REQ] [SendData] callback id: 91 transmit status: OK 09:38:25.637 SERIAL « 0x0108000400060298402f (10 bytes) 09:38:25.638 SERIAL » [ACK] (0x06) 09:38:25.639 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:38:25.646 SERIAL » 0x01110013060a98802c3f0048009287de24005d (19 bytes) 09:38:25.646 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x2c3f0048009287de 09:38:25.648 SERIAL « [ACK] (0x06) 09:38:25.655 SERIAL « 0x0104011301e8 (6 bytes) 09:38:25.656 SERIAL » [ACK] (0x06) 09:38:25.656 DRIVER « [RES] [SendData] was sent: true 09:38:25.697 SERIAL « 0x0121000400061b98818923c42bf6d833e9c38f00d1541ada9b2cb3f02fa9ed27a (35 bytes) f0d7c 09:38:25.698 SERIAL » [ACK] (0x06) 09:38:25.700 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 09:38:25.710 SERIAL » 0x010800131d0100255c81 (10 bytes) 09:38:25.710 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 92 └─[NoOperationCC] 09:38:25.711 CNTRLR « [Node 006] received endpoints: 1, 2 09:38:25.711 CNTRLR » [Node 006] querying capabilities for endpoint #1... 09:38:25.716 SERIAL « [ACK] (0x06) 09:38:25.718 SERIAL « 0x0104011301e8 (6 bytes) 09:38:25.719 SERIAL » [ACK] (0x06) 09:38:25.719 DRIVER « [RES] [SendData] was sent: true 09:38:27.213 SERIAL « 0x010700135c00009621 (9 bytes) 09:38:27.214 SERIAL » [ACK] (0x06) 09:38:27.214 DRIVER « [REQ] [SendData] callback id: 92 transmit status: OK 09:38:27.223 SERIAL » 0x010d00131c06600d00028002255d6e (15 bytes) 09:38:27.223 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 93 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[BatteryCCGet] 09:38:27.224 CNTRLR « [Node 029] ping successful 09:38:27.228 CNTRLR [Node 029] ManufacturerSpecificCC: doing a partial interview... 09:38:27.229 CNTRLR [Node 029] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:38:27.299 SERIAL « [ACK] (0x06) 09:38:27.314 SERIAL « 0x0104011301e8 (6 bytes) 09:38:27.314 SERIAL » [ACK] (0x06) 09:38:27.315 DRIVER « [RES] [SendData] was sent: true 09:38:27.318 CNTRLR [Node 029] VersionCC: doing a partial interview... 09:38:27.319 CNTRLR [Node 029] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:38:27.322 CNTRLR [Node 029] trying to load device config 09:38:27.328 CNTRLR [Node 029] device config loaded 09:38:27.329 CNTRLR [Node 029] ZWavePlusCC: doing a partial interview... 09:38:27.330 CNTRLR [Node 029] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:38:27.330 CNTRLR » [Node 029] querying device endpoint information... 09:38:28.609 SERIAL « 0x010700135d00008a3c (9 bytes) 09:38:28.610 SERIAL » [ACK] (0x06) 09:38:28.611 DRIVER « [REQ] [SendData] callback id: 93 transmit status: OK 09:38:28.724 SERIAL « 0x010d0004001c07600d020080036465 (15 bytes) 09:38:28.726 CNTRLR [Node 028] [~] [Battery] level: 100 => 100 [Endpoint 2] 09:38:28.727 CNTRLR [Node 028] [~] [Battery] isLow: false => false [Endpoint 2] 09:38:28.728 SERIAL » [ACK] (0x06) 09:38:28.730 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BatteryCCReport] level: 100 is low: false 09:38:28.737 SERIAL » 0x010900131d026007255ee6 (11 bytes) 09:38:28.737 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 94 └─[MultiChannelCCEndPointGet] 09:38:28.738 CNTRLR « [Node 028] received response for battery information: [Endpoint 2] level: 100 09:38:28.739 CNTRLR [Node 028] [~] [Battery] interviewComplete: true => tr [Endpoint 2] [internal] ue 09:38:28.814 SERIAL « [ACK] (0x06) 09:38:28.818 SERIAL « 0x0104011301e8 (6 bytes) 09:38:28.819 SERIAL » [ACK] (0x06) 09:38:28.821 DRIVER « [RES] [SendData] was sent: true 09:38:28.823 CNTRLR [Node 028] MultilevelSensorCC: doing a partial interview... 09:38:28.823 CNTRLR » [Node 028] querying Air temperature sensor reading... 09:38:30.263 SERIAL « 0x010700135e0000992c (9 bytes) 09:38:30.263 SERIAL » [ACK] (0x06) 09:38:30.264 DRIVER « [REQ] [SendData] callback id: 94 transmit status: OK 09:38:30.343 SERIAL « 0x010b0004001d05600800020082 (13 bytes) 09:38:30.343 CNTRLR [Node 029] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:38:30.344 CNTRLR [Node 029] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 09:38:30.344 CNTRLR [Node 029] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:38:30.344 CNTRLR [Node 029] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 09:38:30.344 SERIAL » [ACK] (0x06) 09:38:30.345 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:38:30.348 SERIAL » 0x010a00131803700512255fe0 (12 bytes) 09:38:30.348 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 95 └─[ConfigurationCCGet] parameter #: 18 09:38:30.349 CNTRLR « [Node 029] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:38:30.349 CNTRLR » [Node 029] querying all endpoints... 09:38:30.354 SERIAL « [ACK] (0x06) 09:38:30.356 SERIAL « 0x0104011301e8 (6 bytes) 09:38:30.356 SERIAL » [ACK] (0x06) 09:38:30.357 DRIVER « [RES] [SendData] was sent: true 09:38:30.441 SERIAL « 0x010700135f000009bd (9 bytes) 09:38:30.441 SERIAL » [ACK] (0x06) 09:38:30.442 DRIVER « [REQ] [SendData] callback id: 95 transmit status: OK 09:38:30.455 SERIAL « 0x010c00040018067006120200058a (14 bytes) 09:38:30.461 CNTRLR [Node 024] [~] [Configuration] 18: 5 => 5 09:38:30.462 SERIAL » [ACK] (0x06) 09:38:30.463 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 18 value size: 2 value: 5 09:38:30.466 SERIAL » 0x010b00131d04600bffff2560d0 (13 bytes) 09:38:30.466 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 96 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:38:30.466 CNTRLR « [Node 024] parameter #18 has value: 5 09:38:30.467 CNTRLR » [Node 024] querying parameter #20 value... 09:38:30.475 SERIAL « [ACK] (0x06) 09:38:30.477 SERIAL « 0x0104011301e8 (6 bytes) 09:38:30.478 SERIAL » [ACK] (0x06) 09:38:30.480 DRIVER « [RES] [SendData] was sent: true 09:38:30.556 SERIAL « 0x010700136000000982 (9 bytes) 09:38:30.557 SERIAL » [ACK] (0x06) 09:38:30.557 DRIVER « [REQ] [SendData] callback id: 96 transmit status: OK 09:38:30.645 SERIAL « 0x010d0004001d07600c00ffff010283 (15 bytes) 09:38:30.645 SERIAL » [ACK] (0x06) 09:38:30.646 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 09:38:30.649 SERIAL » 0x010a00131a037005232561ed (12 bytes) 09:38:30.649 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 97 └─[ConfigurationCCGet] parameter #: 35 09:38:30.650 CNTRLR « [Node 029] received endpoints: 1, 2 09:38:30.650 CNTRLR » [Node 029] querying capabilities for endpoint #1... 09:38:30.653 SERIAL « [ACK] (0x06) 09:38:30.658 SERIAL « 0x0104011301e8 (6 bytes) 09:38:30.658 SERIAL » [ACK] (0x06) 09:38:30.658 DRIVER « [RES] [SendData] was sent: true 09:38:30.738 SERIAL « 0x010700136100000882 (9 bytes) 09:38:30.738 SERIAL » [ACK] (0x06) 09:38:30.739 DRIVER « [REQ] [SendData] callback id: 97 transmit status: OK 09:38:30.748 SERIAL « 0x010b0004001a057006230101ba (13 bytes) 09:38:30.753 CNTRLR [Node 026] [~] [Configuration] 35: 1 => 1 09:38:30.754 SERIAL » [ACK] (0x06) 09:38:30.755 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 1 09:38:30.758 SERIAL » 0x010a00131d036009012562d7 (12 bytes) 09:38:30.758 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 98 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:38:30.758 CNTRLR « [Node 026] parameter #35 has value: 1 09:38:30.759 CNTRLR » [Node 026] querying parameter #40 value... 09:38:30.762 SERIAL « [ACK] (0x06) 09:38:30.767 SERIAL « 0x0104011301e8 (6 bytes) 09:38:30.768 SERIAL » [ACK] (0x06) 09:38:30.768 DRIVER « [RES] [SendData] was sent: true 09:38:30.849 SERIAL « 0x010700136200000980 (9 bytes) 09:38:30.849 SERIAL » [ACK] (0x06) 09:38:30.850 DRIVER « [REQ] [SendData] callback id: 98 transmit status: OK 09:38:30.944 SERIAL « 0x011a0004001d14600a0108065e8e404353989f596c7175808185229d (28 bytes) 09:38:30.946 CNTRLR [Node 029] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 1] [internal] 64,67,83,152,159,89,108,113,117,128,129,133,34 => 94,142,64,67,83,152,159,89,1 08,113,117,128,129,133,34 09:38:30.946 SERIAL » [ACK] (0x06) 09:38:30.948 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:38:30.954 SERIAL » 0x0109001316028105256333 (11 bytes) 09:38:30.955 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 99 └─[ClockCCGet] 09:38:30.956 CNTRLR « [Node 029] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:38:30.956 CNTRLR » [Node 029] querying capabilities for endpoint #2... 09:38:30.962 SERIAL « [ACK] (0x06) 09:38:30.964 SERIAL « 0x0104011301e8 (6 bytes) 09:38:30.964 SERIAL » [ACK] (0x06) 09:38:30.965 DRIVER « [RES] [SendData] was sent: true 09:38:32.408 SERIAL « 0x010700136300009018 (9 bytes) 09:38:32.409 SERIAL » [ACK] (0x06) 09:38:32.409 DRIVER « [REQ] [SendData] callback id: 99 transmit status: OK 09:38:32.432 SERIAL « 0x01080004001e0284076c (10 bytes) 09:38:32.432 SERIAL » [ACK] (0x06) 09:38:32.433 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:38:32.433 CNTRLR « [Node 030] received wakeup notification 09:38:32.434 CNTRLR [Node 030] The node is awake. 09:38:32.435 CNTRLR [Node 030] The node is ready to be used 09:38:32.739 SERIAL « 0x010a00040016048106e91e93 (12 bytes) 09:38:32.740 SERIAL » [ACK] (0x06) 09:38:32.742 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ClockCCReport] clock setting: Sunday, 09:30 09:38:32.746 SERIAL » 0x010a00131d036009022564d2 (12 bytes) 09:38:32.747 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 100 └─[MultiChannelCCCapabilityGet] endpoint: 2 09:38:32.747 CNTRLR « [Node 022] received current clock setting: Sunday, 09:30 09:38:32.748 CNTRLR [Node 022] [~] [Clock] interviewComplete: true => true [Endpoint 0] [internal] 09:38:32.789 SERIAL « [ACK] (0x06) 09:38:32.793 SERIAL « 0x0104011301e8 (6 bytes) 09:38:32.793 SERIAL » [ACK] (0x06) 09:38:32.796 DRIVER « [RES] [SendData] was sent: true 09:38:32.798 CNTRLR [Node 022] AssociationCC: doing a partial interview... 09:38:32.799 CNTRLR [Node 022] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 09:38:32.800 CNTRLR [Node 022] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:38:32.800 CNTRLR [Node 022] MultiChannelAssociationCC: doing a partial interview... 09:38:32.800 CNTRLR » [Node 022] querying multi channel association group #1... 09:38:34.217 SERIAL « 0x01070013640000931c (9 bytes) 09:38:34.217 SERIAL » [ACK] (0x06) 09:38:34.218 DRIVER « [REQ] [SendData] callback id: 100 transmit status: OK 09:38:34.307 SERIAL « 0x01160004001d10600a0221015e8e31989f596c718085222d (24 bytes) 09:38:34.308 CNTRLR [Node 029] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 2] [internal] 49,152,159,89,108,113,128,133,34 => 94,142,49,152,159,89,108,113,128,133,34 09:38:34.308 SERIAL » [ACK] (0x06) 09:38:34.309 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:38:34.315 SERIAL » 0x010a001316038e020125653e (12 bytes) 09:38:34.316 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 101 └─[MultiChannelAssociationCCGet] group id: 1 09:38:34.317 CNTRLR « [Node 029] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:38:34.317 CNTRLR [Node 029] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:38:34.366 SERIAL « [ACK] (0x06) 09:38:34.371 SERIAL « 0x0104011301e8 (6 bytes) 09:38:34.371 SERIAL » [ACK] (0x06) 09:38:34.372 DRIVER « [RES] [SendData] was sent: true 09:38:34.375 CNTRLR [Node 029] BatteryCC: doing a partial interview... 09:38:34.376 CNTRLR » [Node 029] querying battery status... 09:38:35.755 SERIAL « 0x01070013650000901e (9 bytes) 09:38:35.755 SERIAL » [ACK] (0x06) 09:38:35.756 DRIVER « [REQ] [SendData] callback id: 101 transmit status: OK 09:38:35.840 SERIAL « 0x010e00040016088e0301010000010067 (16 bytes) 09:38:35.841 SERIAL » [ACK] (0x06) 09:38:35.843 CNTRLR [Node 022] [~] [Multi Channel Association] maxNodes[1]: 1 => 1 09:38:35.844 CNTRLR [Node 022] [~] [Multi Channel Association] nodeIds[1]: => 09:38:35.845 CNTRLR [Node 022] [~] [Multi Channel Association] endpoints[1]: [object Object] => [o bject Object] 09:38:35.846 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 1 node ids: endpoints: 1:0 09:38:35.849 SERIAL » 0x010900131d02800225663b (11 bytes) 09:38:35.849 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 102 └─[BatteryCCGet] 09:38:35.850 CNTRLR « [Node 022] received information for multi channel association group #1: maximum # of nodes: 1 currently assigned nodes: currently assigned endpoints: 1:0 09:38:35.851 CNTRLR [Node 022] [~] [Association] hasLifeline: true => true [internal] 09:38:35.851 CNTRLR [Node 022] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 09:38:35.880 SERIAL « [ACK] (0x06) 09:38:35.881 SERIAL « 0x0104011301e8 (6 bytes) 09:38:35.881 SERIAL » [ACK] (0x06) 09:38:35.881 DRIVER « [RES] [SendData] was sent: true 09:38:35.960 SERIAL « 0x0108000410080284076a (10 bytes) 09:38:35.961 SERIAL » [ACK] (0x06) 09:38:35.961 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:38:35.962 CNTRLR « [Node 008] received wakeup notification 09:38:35.963 CNTRLR [Node 008] The node is now awake. 09:38:36.021 SERIAL « 0x0108000410080284076a (10 bytes) 09:38:36.022 SERIAL » [ACK] (0x06) 09:38:36.022 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:38:36.023 CNTRLR « [Node 008] received wakeup notification 09:38:36.045 SERIAL « 0x0108000410080284076a (10 bytes) 09:38:36.045 SERIAL » [ACK] (0x06) 09:38:36.046 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:38:36.047 CNTRLR « [Node 008] received wakeup notification 09:38:36.092 SERIAL « 0x0108000410080284076a (10 bytes) 09:38:36.092 SERIAL » [ACK] (0x06) 09:38:36.093 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:38:36.094 CNTRLR « [Node 008] received wakeup notification 09:38:36.142 SERIAL « 0x0108000410080284076a (10 bytes) 09:38:36.143 SERIAL » [ACK] (0x06) 09:38:36.143 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:38:36.144 CNTRLR « [Node 008] received wakeup notification 09:38:36.221 SERIAL « 0x0108000410080284076a (10 bytes) 09:38:36.221 SERIAL » [ACK] (0x06) 09:38:36.222 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:38:36.223 CNTRLR « [Node 008] received wakeup notification 09:38:36.244 CNTRLR [Node 022] AssociationGroupInfoCC: doing a partial interview... 09:38:36.245 CNTRLR [Node 022] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 09:38:36.246 CNTRLR [Node 022] NotificationCC: doing a partial interview... 09:38:36.247 CNTRLR [Node 022] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 09:38:36.247 CNTRLR [Node 022] Interview stage completed: CommandClasses 09:38:36.247 CNTRLR [Node 022] Interview stage completed: OverwriteConfig 09:38:36.247 CNTRLR » [Node 022] requesting node neighbors... 09:38:36.250 SERIAL « 0x0108000410080284076a (10 bytes) 09:38:36.250 SERIAL » [ACK] (0x06) 09:38:36.251 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:38:36.252 CNTRLR « [Node 008] received wakeup notification 09:38:36.270 SERIAL « 0x0108000410080284076a (10 bytes) 09:38:36.271 SERIAL » [ACK] (0x06) 09:38:36.272 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:38:36.273 CNTRLR « [Node 008] received wakeup notification 09:38:37.472 SERIAL « 0x0108000410080284076a (10 bytes) 09:38:37.472 SERIAL » [ACK] (0x06) 09:38:37.473 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:38:37.475 CNTRLR « [Node 008] received wakeup notification 09:38:37.480 SERIAL « 0x0108000410080284076a (10 bytes) 09:38:37.480 SERIAL » [ACK] (0x06) 09:38:37.481 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:38:37.483 CNTRLR « [Node 008] received wakeup notification 09:38:37.506 SERIAL « 0x01070013660000a528 (9 bytes) 09:38:37.506 SERIAL » [ACK] (0x06) 09:38:37.507 DRIVER « [REQ] [SendData] callback id: 102 transmit status: OK 09:38:39.111 CNTRLR [Node 029] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:38:39.615 SERIAL » 0x010900131d02800225663b (11 bytes) 09:38:39.616 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 102 └─[BatteryCCGet] 09:38:39.618 SERIAL « [ACK] (0x06) 09:38:39.624 SERIAL « 0x0104011301e8 (6 bytes) 09:38:39.625 SERIAL » [ACK] (0x06) 09:38:39.626 DRIVER « [RES] [SendData] was sent: true 09:38:39.705 SERIAL « 0x010700136600000984 (9 bytes) 09:38:39.706 SERIAL » [ACK] (0x06) 09:38:39.713 DRIVER « [REQ] [SendData] callback id: 102 transmit status: OK 09:38:39.784 SERIAL « 0x01090004001d038003630c (11 bytes) 09:38:39.785 CNTRLR [Node 029] [~] [Battery] level: 99 => 99 [Endpoint 0] 09:38:39.786 CNTRLR [Node 029] [~] [Battery] isLow: false => false [Endpoint 0] 09:38:39.786 SERIAL » [ACK] (0x06) 09:38:39.788 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 99 is low: false 09:38:39.793 SERIAL » 0x01070080160000006e (9 bytes) 09:38:39.793 DRIVER » [Node 022] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:38:39.794 CNTRLR « [Node 029] received response for battery information: level: 99 09:38:39.795 CNTRLR [Node 029] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:38:39.847 SERIAL « [ACK] (0x06) 09:38:39.848 SERIAL « 0x0120018065f8ce530700000000000000000000000000000000000000000000000 (34 bytes) 059 09:38:39.849 SERIAL » [ACK] (0x06) 09:38:39.852 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 12, 13, 14, 15, 16, 18, 19, 20, 23, 24, 25, 26, 29, 31 , 33, 34, 35 09:38:39.859 SERIAL » 0x010900130602984025677b (11 bytes) 09:38:39.860 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 103 └─[SecurityCCNonceGet] 09:38:39.860 CNTRLR « [Node 022] node neighbors received: 1, 3, 6, 7, 12, 13, 14, 15, 16, 18, 19, 20, 23, 24, 25, 26, 29, 31, 33, 34, 35 09:38:39.861 CNTRLR [Node 022] Interview stage completed: Neighbors 09:38:39.861 CNTRLR [Node 022] Interview completed 09:38:39.864 SERIAL « [ACK] (0x06) 09:38:39.866 CNTRLR [Node 029] WakeUpCC: doing a partial interview... 09:38:39.866 CNTRLR [Node 029] skipping wakeup configuration for frequent listening device 09:38:39.866 CNTRLR [Node 029] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:38:39.869 CNTRLR [Node 029] ZWavePlusCC: doing a partial interview... [Endpoint 1] 09:38:39.869 CNTRLR [Node 029] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 09:38:39.870 CNTRLR [Node 029] ThermostatModeCC: doing a partial interview... [Endpoint 1] 09:38:39.870 CNTRLR » [Node 029] querying current thermostat mode... [Endpoint 1] 09:38:39.873 SERIAL « 0x0104011301e8 (6 bytes) 09:38:39.873 SERIAL » [ACK] (0x06) 09:38:39.874 DRIVER « [RES] [SendData] was sent: true 09:38:41.133 SERIAL « 0x010700136700007ff3 (9 bytes) 09:38:41.134 SERIAL » [ACK] (0x06) 09:38:41.135 DRIVER « [REQ] [SendData] callback id: 103 transmit status: OK 09:38:41.156 SERIAL « 0x0110000400060a98805a14800203a2a46056 (18 bytes) 09:38:41.157 SERIAL » [ACK] (0x06) 09:38:41.158 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x5a14800203a2a460 09:38:41.164 SERIAL » 0x011e00130617988177d84ad00d8aa91ca910d72f5af434cb01eda8aefc2568b6 (32 bytes) 09:38:41.165 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 104 └─[SecurityCCCommandEncapsulation] │ nonce id: 90 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:38:41.168 SERIAL « [ACK] (0x06) 09:38:41.175 SERIAL « 0x0104011301e8 (6 bytes) 09:38:41.176 SERIAL » [ACK] (0x06) 09:38:41.177 DRIVER « [RES] [SendData] was sent: true 09:38:41.200 SERIAL « 0x010700136800000380 (9 bytes) 09:38:41.201 SERIAL » [ACK] (0x06) 09:38:41.202 DRIVER « [REQ] [SendData] callback id: 104 transmit status: OK 09:38:41.222 SERIAL « 0x0108000400060298402f (10 bytes) 09:38:41.223 SERIAL » [ACK] (0x06) 09:38:41.224 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:38:41.231 SERIAL » 0x01110013060a988040e48e77cc4f740d24006a (19 bytes) 09:38:41.231 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x40e48e77cc4f740d 09:38:41.233 SERIAL « [ACK] (0x06) 09:38:41.240 SERIAL « 0x0104011301e8 (6 bytes) 09:38:41.240 SERIAL » [ACK] (0x06) 09:38:41.241 DRIVER « [RES] [SendData] was sent: true 09:38:41.283 SERIAL « 0x0123000400061d988173ef19473f361b27a0778083c147e913848c40d38210845 (37 bytes) fae789617 09:38:41.285 SERIAL » [ACK] (0x06) 09:38:41.287 CNTRLR [Node 006] [~] [Multi Channel] commandClasses: 94,152, [Endpoint 1] [internal] 159,34 => 94,152,159,34 09:38:41.288 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 09:38:41.296 SERIAL » 0x010d00131d06600d00014002256998 (15 bytes) 09:38:41.296 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 105 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:38:41.297 CNTRLR « [Node 006] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 09:38:41.297 CNTRLR » [Node 006] querying capabilities for endpoint #2... 09:38:41.304 SERIAL « [ACK] (0x06) 09:38:41.306 SERIAL « 0x0104011301e8 (6 bytes) 09:38:41.307 SERIAL » [ACK] (0x06) 09:38:41.308 DRIVER « [RES] [SendData] was sent: true 09:38:41.388 SERIAL « 0x01070013690000098b (9 bytes) 09:38:41.388 SERIAL » [ACK] (0x06) 09:38:41.389 DRIVER « [REQ] [SendData] callback id: 105 transmit status: OK 09:38:41.493 SERIAL « 0x010d0004001d07600d0100400301c2 (15 bytes) 09:38:41.494 CNTRLR [Node 029] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 09:38:41.495 SERIAL » [ACK] (0x06) 09:38:41.496 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 09:38:41.500 SERIAL » 0x010b00131c0431040100256a84 (13 bytes) 09:38:41.501 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 106 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:38:41.501 CNTRLR « [Node 029] received current thermostat mode: Heat [Endpoint 1] 09:38:41.502 CNTRLR [Node 029] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 1] [internal] ue => true 09:38:41.531 SERIAL « [ACK] (0x06) 09:38:41.534 SERIAL « 0x0104011301e8 (6 bytes) 09:38:41.535 SERIAL » [ACK] (0x06) 09:38:41.536 DRIVER « [RES] [SendData] was sent: true 09:38:41.538 CNTRLR [Node 029] ThermostatSetpointCC: doing a partial interview... [Endpoint 1] 09:38:41.538 CNTRLR » [Node 029] querying current value of setpoint Heating... [Endpoint 1] 09:38:42.435 DRIVER The awake timeout for node 30 has elapsed. Assuming it is asleep. 09:38:42.436 CNTRLR [Node 030] The node is now asleep. 09:38:42.437 CNTRLR [Node 030] ping failed: The node is asleep 09:38:42.439 CNTRLR [Node 030] ManufacturerSpecificCC: doing a partial interview... 09:38:42.440 CNTRLR [Node 030] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:38:42.473 CNTRLR [Node 030] VersionCC: doing a partial interview... 09:38:42.473 CNTRLR [Node 030] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:38:42.473 CNTRLR [Node 030] trying to load device config 09:38:42.486 CNTRLR [Node 030] device config loaded 09:38:42.487 CNTRLR [Node 030] BatteryCC: doing a partial interview... 09:38:42.487 CNTRLR » [Node 030] querying battery status... 09:38:42.952 SERIAL « 0x010700136a00009110 (9 bytes) 09:38:42.952 SERIAL » [ACK] (0x06) 09:38:42.953 DRIVER « [REQ] [SendData] callback id: 106 transmit status: OK 09:38:43.070 SERIAL « 0x010c0004001c063105012200c832 (14 bytes) 09:38:43.071 CNTRLR [Node 028] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 09:38:43.072 CNTRLR [Node 028] [~] [Multilevel Sensor] Air temperature: 19.8 => 20 [Endpoint 0] 09:38:43.072 SERIAL » [ACK] (0x06) 09:38:43.073 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 20 09:38:43.076 SERIAL » 0x010e00131d07600d0001430201256b9a (16 bytes) 09:38:43.076 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 107 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:38:43.077 CNTRLR « [Node 028] received current Air temperature sensor reading: 20 °C 09:38:43.077 CNTRLR [Node 028] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 09:38:43.077 CNTRLR [Node 028] ThermostatModeCC: doing a partial interview... 09:38:43.077 CNTRLR » [Node 028] querying current thermostat mode... 09:38:43.080 SERIAL « [ACK] (0x06) 09:38:43.085 SERIAL « 0x0104011301e8 (6 bytes) 09:38:43.085 SERIAL » [ACK] (0x06) 09:38:43.085 DRIVER « [RES] [SendData] was sent: true 09:38:44.611 SERIAL « 0x010700136b00009919 (9 bytes) 09:38:44.611 SERIAL » [ACK] (0x06) 09:38:44.612 DRIVER « [REQ] [SendData] callback id: 107 transmit status: OK 09:38:44.732 SERIAL « 0x01100004001d0a600d01004303012200a053 (18 bytes) 09:38:44.734 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpoint[1]: 16 => 16 [Endpoint 1] 09:38:44.736 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 09:38:44.736 SERIAL » [ACK] (0x06) 09:38:44.738 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 16 °C 09:38:44.744 SERIAL » 0x010a00131803700514256cd5 (12 bytes) 09:38:44.745 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 108 └─[ConfigurationCCGet] parameter #: 20 09:38:44.746 CNTRLR « [Node 029] received current value of setpoint Heating: 16 °C [Endpoint 1] 09:38:44.747 CNTRLR [Node 029] [~] [Thermostat Setpoint] interviewComplete [Endpoint 1] [internal] : true => true 09:38:44.820 SERIAL « [ACK] (0x06) 09:38:44.826 SERIAL « 0x0104011301e8 (6 bytes) 09:38:44.827 SERIAL » [ACK] (0x06) 09:38:44.829 DRIVER « [RES] [SendData] was sent: true 09:38:44.833 CNTRLR [Node 029] NotificationCC: doing a partial interview... [Endpoint 1] 09:38:44.834 CNTRLR » [Node 029] querying notification status for Power Management... [Endpoint 1] 09:38:44.837 SERIAL « 0x010700136c0000098e (9 bytes) 09:38:44.837 SERIAL » [ACK] (0x06) 09:38:44.838 DRIVER « [REQ] [SendData] callback id: 108 transmit status: OK 09:38:44.845 SERIAL « 0x010b000400180570061401028c (13 bytes) 09:38:44.850 CNTRLR [Node 024] [~] [Configuration] 20: 2 => 2 09:38:44.851 SERIAL » [ACK] (0x06) 09:38:44.852 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 2 09:38:44.855 SERIAL » 0x011000131d09600d00017104000800256db1 (18 bytes) 09:38:44.855 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 109 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: Power Management 09:38:44.856 CNTRLR « [Node 024] parameter #20 has value: 2 09:38:44.856 CNTRLR » [Node 024] querying parameter #21 value... 09:38:44.859 SERIAL « [ACK] (0x06) 09:38:44.865 SERIAL « 0x0104011301e8 (6 bytes) 09:38:44.865 SERIAL » [ACK] (0x06) 09:38:44.866 DRIVER « [RES] [SendData] was sent: true 09:38:44.951 SERIAL « 0x010700136d0000098f (9 bytes) 09:38:44.951 SERIAL » [ACK] (0x06) 09:38:44.951 DRIVER « [REQ] [SendData] callback id: 109 transmit status: OK 09:38:45.043 SERIAL « 0x01130004001d0d600d01007105000000ff08fe00e9 (21 bytes) 09:38:45.044 SERIAL » [ACK] (0x06) 09:38:45.045 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 09:38:45.048 SERIAL » 0x010a00131a03700528256ee9 (12 bytes) 09:38:45.049 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 110 └─[ConfigurationCCGet] parameter #: 40 09:38:45.050 CNTRLR [Node 029] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 1] 54 09:38:45.051 CNTRLR » [Node 029] querying notification status for System... [Endpoint 1] 09:38:45.055 SERIAL « [ACK] (0x06) 09:38:45.057 SERIAL « 0x0104011301e8 (6 bytes) 09:38:45.057 SERIAL » [ACK] (0x06) 09:38:45.058 DRIVER « [RES] [SendData] was sent: true 09:38:45.128 SERIAL « 0x010700136e00000782 (9 bytes) 09:38:45.128 SERIAL » [ACK] (0x06) 09:38:45.129 DRIVER « [REQ] [SendData] callback id: 110 transmit status: OK 09:38:45.138 SERIAL « 0x010b0004001a05700628010aba (13 bytes) 09:38:45.146 CNTRLR [Node 026] [~] [Configuration] 40: 10 => 10 09:38:45.147 SERIAL » [ACK] (0x06) 09:38:45.147 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 10 09:38:45.150 SERIAL » 0x011000131d09600d00017104000900256fb2 (18 bytes) 09:38:45.151 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 111 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: System 09:38:45.151 CNTRLR « [Node 026] parameter #40 has value: 10 09:38:45.151 CNTRLR » [Node 026] querying parameter #42 value... 09:38:45.154 SERIAL « [ACK] (0x06) 09:38:45.159 SERIAL « 0x0104011301e8 (6 bytes) 09:38:45.159 SERIAL » [ACK] (0x06) 09:38:45.160 DRIVER « [RES] [SendData] was sent: true 09:38:45.247 SERIAL « 0x010700136f0000098d (9 bytes) 09:38:45.247 SERIAL » [ACK] (0x06) 09:38:45.247 DRIVER « [REQ] [SendData] callback id: 111 transmit status: OK 09:38:45.333 SERIAL « 0x01130004001d0d600d01007105000000ff09fe00e8 (21 bytes) 09:38:45.338 SERIAL » [ACK] (0x06) 09:38:45.339 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: System notification status: 255 notification event: Unknown (0xfe) 09:38:45.344 SERIAL » 0x010900130602984025706c (11 bytes) 09:38:45.344 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 112 └─[SecurityCCNonceGet] 09:38:45.345 CNTRLR [Node 029] [~] [Notification] System[unknown]: 254 => 254 [Endpoint 1] 09:38:45.346 CNTRLR [Node 029] [~] [Notification] interviewComplete: true [Endpoint 1] [internal] => true 09:38:45.374 SERIAL « [ACK] (0x06) 09:38:45.377 SERIAL « 0x0104011301e8 (6 bytes) 09:38:45.378 SERIAL » [ACK] (0x06) 09:38:45.378 DRIVER « [RES] [SendData] was sent: true 09:38:45.380 CNTRLR [Node 029] ProtectionCC: doing a partial interview... 09:38:45.381 CNTRLR » [Node 029] querying protection status... 09:38:45.964 DRIVER The awake timeout for node 8 has elapsed. Assuming it is asleep. 09:38:45.964 CNTRLR [Node 008] The node is now asleep. 09:38:46.691 SERIAL « 0x01070013700000861d (9 bytes) 09:38:46.692 SERIAL » [ACK] (0x06) 09:38:46.693 DRIVER « [REQ] [SendData] callback id: 112 transmit status: OK 09:38:46.713 SERIAL « 0x0110000400060a9880226b55c7f2a750af8e (18 bytes) 09:38:46.715 SERIAL » [ACK] (0x06) 09:38:46.716 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x226b55c7f2a750af 09:38:46.724 SERIAL » 0x011e001306179881cb6352afe1d8fec4fbd16fe6224d2d2fe993d36bd6257122 (32 bytes) 09:38:46.725 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 113 └─[SecurityCCCommandEncapsulation] │ nonce id: 34 └─[MultiChannelCCCapabilityGet] endpoint: 2 09:38:46.728 SERIAL « [ACK] (0x06) 09:38:46.735 SERIAL « 0x0104011301e8 (6 bytes) 09:38:46.736 SERIAL » [ACK] (0x06) 09:38:46.736 DRIVER « [RES] [SendData] was sent: true 09:38:46.742 SERIAL « 0x01090004000b0380034b32 (11 bytes) 09:38:46.744 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 09:38:46.745 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 09:38:46.746 SERIAL » [ACK] (0x06) 09:38:46.748 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 09:38:46.812 SERIAL « 0x0110000400060a9880226b55c7f2a750af8e (18 bytes) 09:38:46.813 SERIAL » [ACK] (0x06) 09:38:46.814 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x226b55c7f2a750af 09:38:46.845 SERIAL « 0x010700137100000c96 (9 bytes) 09:38:46.846 SERIAL » [ACK] (0x06) 09:38:46.846 DRIVER « [REQ] [SendData] callback id: 113 transmit status: OK 09:38:46.867 SERIAL « 0x0108000400060298402f (10 bytes) 09:38:46.868 SERIAL » [ACK] (0x06) 09:38:46.869 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:38:46.881 SERIAL » 0x01110013060a9880b87f343c07a551562400a7 (19 bytes) 09:38:46.881 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xb87f343c07a55156 09:38:46.883 SERIAL « [ACK] (0x06) 09:38:46.890 SERIAL « 0x0104011301e8 (6 bytes) 09:38:46.891 SERIAL » [ACK] (0x06) 09:38:46.891 DRIVER « [RES] [SendData] was sent: true 09:38:46.935 SERIAL « 0x0123000400061d988131fb7824b24eeb1c9819b046b1e43c8c88ecb824e9be083 (37 bytes) 8a6f0ecf0 09:38:46.936 SERIAL » [ACK] (0x06) 09:38:46.938 CNTRLR [Node 006] [~] [Multi Channel] commandClasses: 94,152, [Endpoint 2] [internal] 159,34 => 94,152,159,34 09:38:46.939 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 09:38:46.946 SERIAL » 0x010800131f01002572ad (10 bytes) 09:38:46.947 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 114 └─[NoOperationCC] 09:38:46.947 CNTRLR « [Node 006] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 09:38:46.948 CNTRLR [Node 006] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:38:46.983 SERIAL « [ACK] (0x06) 09:38:46.987 SERIAL « 0x0104011301e8 (6 bytes) 09:38:46.987 SERIAL » [ACK] (0x06) 09:38:46.988 DRIVER « [RES] [SendData] was sent: true 09:38:46.990 CNTRLR [Node 006] BatteryCC: doing a partial interview... 09:38:46.990 CNTRLR » [Node 006] querying battery status... 09:38:46.993 SERIAL « 0x01070013720000039a (9 bytes) 09:38:46.993 SERIAL » [ACK] (0x06) 09:38:46.994 DRIVER « [REQ] [SendData] callback id: 114 transmit status: OK 09:38:46.999 SERIAL » 0x010d00131d06600d000175022573b7 (15 bytes) 09:38:46.999 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 115 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 09:38:47.000 CNTRLR « [Node 031] ping successful 09:38:47.001 CNTRLR [Node 031] ManufacturerSpecificCC: doing a partial interview... 09:38:47.001 CNTRLR [Node 031] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:38:47.002 CNTRLR [Node 031] VersionCC: doing a partial interview... 09:38:47.002 CNTRLR [Node 031] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:38:47.003 CNTRLR [Node 031] trying to load device config 09:38:47.005 SERIAL « [ACK] (0x06) 09:38:47.017 CNTRLR [Node 031] device config loaded 09:38:47.017 CNTRLR » [Node 031] querying device endpoint information... 09:38:47.021 SERIAL « 0x0104011301e8 (6 bytes) 09:38:47.021 SERIAL » [ACK] (0x06) 09:38:47.021 DRIVER « [RES] [SendData] was sent: true 09:38:47.274 SERIAL « 0x010c0004000b0643030142019068 (14 bytes) 09:38:47.275 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpoint[1]: 4 => 4 [Endpoint 0] 09:38:47.276 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 09:38:47.276 SERIAL » [ACK] (0x06) 09:38:47.277 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 4 °C 09:38:47.359 SERIAL « 0x010c0004000306310504220953ba (14 bytes) 09:38:47.359 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:38:47.360 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 227.2 => 238.7 [Endpoint 0] 09:38:47.360 SERIAL » [ACK] (0x06) 09:38:47.361 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 238.7 09:38:48.573 SERIAL « 0x010a0004000b044608007fcf (12 bytes) 09:38:48.576 CNTRLR [Node 011] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 09:38:48.577 CNTRLR [Node 011] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 09:38:48.578 SERIAL » [ACK] (0x06) 09:38:48.581 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ClimateControlScheduleCCOverrideReport] override type: None override state: Unused 09:38:48.626 SERIAL « 0x01080004000b02840779 (10 bytes) 09:38:48.627 SERIAL » [ACK] (0x06) 09:38:48.629 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:38:48.630 CNTRLR « [Node 011] received wakeup notification 09:38:48.631 CNTRLR [Node 011] The node is now awake. 09:38:48.633 CNTRLR [Node 011] expects some queries after wake up, so it shall receive 09:38:48.634 CNTRLR [Node 011] compat query "Battery"::get() 09:38:49.802 SERIAL « 0x010700137300011881 (9 bytes) 09:38:49.802 SERIAL » [ACK] (0x06) 09:38:49.803 DRIVER « [REQ] [SendData] callback id: 115 transmit status: OK 09:38:49.817 SERIAL « 0x01080004000b02840779 (10 bytes) 09:38:49.818 SERIAL » [ACK] (0x06) 09:38:49.819 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:38:49.821 CNTRLR « [Node 011] received wakeup notification 09:38:49.821 CNTRLR [Node 011] expects some queries after wake up, so it shall receive 09:38:49.822 CNTRLR [Node 011] compat query "Battery"::get() 09:38:50.026 SERIAL « 0x010d0004001d07600d0100750300f6 (15 bytes) 09:38:50.027 CNTRLR [Node 029] [~] [Protection] local: 0 => 0 [Endpoint 1] 09:38:50.027 SERIAL » [ACK] (0x06) 09:38:50.028 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ProtectionCCReport] local: Unprotected 09:38:50.031 SERIAL » 0x010900131c0240022574e8 (11 bytes) 09:38:50.032 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 116 └─[ThermostatModeCCGet] 09:38:50.032 CNTRLR « [Node 029] received protection status: local: Unprotected 09:38:50.033 CNTRLR [Node 029] [~] [Protection] interviewComplete: true => [Endpoint 1] [internal] true 09:38:50.061 SERIAL « [ACK] (0x06) 09:38:50.065 SERIAL « 0x0104011301e8 (6 bytes) 09:38:50.065 SERIAL » [ACK] (0x06) 09:38:50.067 DRIVER « [RES] [SendData] was sent: true 09:38:50.068 CNTRLR [Node 029] BatteryCC: doing a partial interview... [Endpoint 1] 09:38:50.068 CNTRLR » [Node 029] querying battery status... [Endpoint 1] 09:38:51.518 SERIAL « 0x01070013740000940b (9 bytes) 09:38:51.519 SERIAL » [ACK] (0x06) 09:38:51.520 DRIVER « [REQ] [SendData] callback id: 116 transmit status: OK 09:38:51.597 SERIAL « 0x010c000400030631050422039271 (14 bytes) 09:38:51.598 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:38:51.599 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 238.7 => 91.4 [Endpoint 0] 09:38:51.600 SERIAL » [ACK] (0x06) 09:38:51.601 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 91.4 09:38:51.634 SERIAL « 0x01090004001c03400301af (11 bytes) 09:38:51.636 CNTRLR [Node 028] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 0] 09:38:51.636 SERIAL » [ACK] (0x06) 09:38:51.637 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ThermostatModeCCReport] mode: Heat 09:38:51.642 SERIAL » 0x010d00131d06600d00018002257544 (15 bytes) 09:38:51.642 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 117 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BatteryCCGet] 09:38:51.643 CNTRLR « [Node 028] received current thermostat mode: Heat 09:38:51.644 CNTRLR [Node 028] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 0] [internal] ue => true 09:38:51.690 SERIAL « [ACK] (0x06) 09:38:51.694 SERIAL « 0x0104011301e8 (6 bytes) 09:38:51.694 SERIAL » [ACK] (0x06) 09:38:51.695 DRIVER « [RES] [SendData] was sent: true 09:38:51.698 CNTRLR [Node 028] ThermostatSetpointCC: doing a partial interview... 09:38:51.699 CNTRLR » [Node 028] querying current value of setpoint Heating... 09:38:53.145 SERIAL « 0x010700137500009608 (9 bytes) 09:38:53.146 SERIAL » [ACK] (0x06) 09:38:53.147 DRIVER « [REQ] [SendData] callback id: 117 transmit status: OK 09:38:53.261 SERIAL « 0x010d0004001d07600d010080036360 (15 bytes) 09:38:53.263 CNTRLR [Node 029] [~] [Battery] level: 99 => 99 [Endpoint 1] 09:38:53.264 CNTRLR [Node 029] [~] [Battery] isLow: false => false [Endpoint 1] 09:38:53.265 SERIAL » [ACK] (0x06) 09:38:53.267 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BatteryCCReport] level: 99 is low: false 09:38:53.276 SERIAL » 0x010a001318037005152576ce (12 bytes) 09:38:53.277 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 118 └─[ConfigurationCCGet] parameter #: 21 09:38:53.279 CNTRLR « [Node 029] received response for battery information: [Endpoint 1] level: 99 09:38:53.281 CNTRLR [Node 029] [~] [Battery] interviewComplete: true => tr [Endpoint 1] [internal] ue 09:38:53.360 SERIAL « [ACK] (0x06) 09:38:53.367 SERIAL « 0x0104011301e8 (6 bytes) 09:38:53.367 SERIAL » [ACK] (0x06) 09:38:53.368 DRIVER « [RES] [SendData] was sent: true 09:38:53.369 SERIAL « 0x010700137600000895 (9 bytes) 09:38:53.370 SERIAL » [ACK] (0x06) 09:38:53.371 CNTRLR [Node 029] ClockCC: doing a partial interview... 09:38:53.371 CNTRLR » [Node 029] requesting current clock setting... 09:38:53.373 DRIVER « [REQ] [SendData] callback id: 118 transmit status: OK 09:38:53.375 SERIAL « 0x010b000400180570061501008f (13 bytes) 09:38:53.380 CNTRLR [Node 024] [~] [Configuration] 21: 0 => 0 09:38:53.381 SERIAL » [ACK] (0x06) 09:38:53.382 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 21 value size: 1 value: 0 09:38:53.385 SERIAL » 0x010d00131d06600d00018105257740 (15 bytes) 09:38:53.385 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 119 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ClockCCGet] 09:38:53.386 CNTRLR « [Node 024] parameter #21 has value: 0 09:38:53.386 CNTRLR » [Node 024] querying parameter #27 value... 09:38:53.390 SERIAL « [ACK] (0x06) 09:38:53.394 SERIAL « 0x0104011301e8 (6 bytes) 09:38:53.395 SERIAL » [ACK] (0x06) 09:38:53.395 DRIVER « [RES] [SendData] was sent: true 09:38:53.477 SERIAL « 0x010700137700000995 (9 bytes) 09:38:53.477 SERIAL » [ACK] (0x06) 09:38:53.477 DRIVER « [REQ] [SendData] callback id: 119 transmit status: OK 09:38:53.563 SERIAL « 0x010e0004001d08600d01008106e927c5 (16 bytes) 09:38:53.564 SERIAL » [ACK] (0x06) 09:38:53.564 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ClockCCReport] clock setting: Sunday, 09:39 09:38:53.567 SERIAL » 0x010a00131a0370052a2578fd (12 bytes) 09:38:53.568 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 120 └─[ConfigurationCCGet] parameter #: 42 09:38:53.568 CNTRLR « [Node 029] received current clock setting: Sunday, 09:39 09:38:53.569 CNTRLR [Node 029] [~] [Clock] interviewComplete: true => true [Endpoint 1] [internal] 09:38:53.595 SERIAL « [ACK] (0x06) 09:38:53.598 SERIAL « 0x0104011301e8 (6 bytes) 09:38:53.598 SERIAL » [ACK] (0x06) 09:38:53.599 DRIVER « [RES] [SendData] was sent: true 09:38:53.602 CNTRLR [Node 029] ZWavePlusCC: doing a partial interview... [Endpoint 2] 09:38:53.603 CNTRLR [Node 029] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 09:38:53.603 CNTRLR [Node 029] MultilevelSensorCC: doing a partial interview... [Endpoint 2] 09:38:53.603 CNTRLR » [Node 029] querying Air temperature sensor reading... [Endpoint 2] 09:38:53.638 SERIAL « 0x01100004001c0a600d02003105012200c94c (18 bytes) 09:38:53.639 CNTRLR [Node 028] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:38:53.640 CNTRLR [Node 028] [~] [Multilevel Sensor] Air temperature: 20 => 20.1 [Endpoint 2] 09:38:53.640 SERIAL » [ACK] (0x06) 09:38:53.641 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 20.1 09:38:53.728 SERIAL « 0x010700137800001083 (9 bytes) 09:38:53.728 SERIAL » [ACK] (0x06) 09:38:53.729 DRIVER « [REQ] [SendData] callback id: 120 transmit status: OK 09:38:53.739 SERIAL « 0x010c0004001a0670062a020e10ab (14 bytes) 09:38:53.744 CNTRLR [Node 026] [~] [Configuration] 42: 3600 => 3600 09:38:53.745 SERIAL » [ACK] (0x06) 09:38:53.745 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 3600 09:38:53.753 SERIAL » 0x010f00131d08600d0002310401002579f1 (17 bytes) 09:38:53.754 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 121 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:38:53.754 CNTRLR « [Node 026] parameter #42 has value: 3600 09:38:53.754 CNTRLR » [Node 026] querying parameter #43 value... 09:38:53.784 SERIAL « [ACK] (0x06) 09:38:53.787 SERIAL « 0x0104011301e8 (6 bytes) 09:38:53.788 SERIAL » [ACK] (0x06) 09:38:53.789 DRIVER « [RES] [SendData] was sent: true 09:38:53.847 SERIAL « 0x01070013790000099b (9 bytes) 09:38:53.847 SERIAL » [ACK] (0x06) 09:38:53.848 DRIVER « [REQ] [SendData] callback id: 121 transmit status: OK 09:38:53.935 SERIAL « 0x01100004001d0a600d02003105012200c246 (18 bytes) 09:38:53.936 CNTRLR [Node 029] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:38:53.936 CNTRLR [Node 029] [~] [Multilevel Sensor] Air temperature: 19.2 => 19.4 [Endpoint 2] 09:38:53.937 SERIAL » [ACK] (0x06) 09:38:53.938 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 19.4 09:38:53.943 SERIAL » 0x0109001306029840257a66 (11 bytes) 09:38:53.943 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 122 └─[SecurityCCNonceGet] 09:38:53.943 CNTRLR « [Node 029] received current Air temperature sensor reading: 19.4 [Endpoint 2] °C 09:38:53.944 CNTRLR [Node 029] [~] [Multilevel Sensor] interviewComplete: [Endpoint 2] [internal] true => true 09:38:53.973 SERIAL « [ACK] (0x06) 09:38:53.983 SERIAL « 0x0104011301e8 (6 bytes) 09:38:53.983 SERIAL » [ACK] (0x06) 09:38:53.984 DRIVER « [RES] [SendData] was sent: true 09:38:53.986 CNTRLR [Node 029] NotificationCC: doing a partial interview... [Endpoint 2] 09:38:53.987 CNTRLR » [Node 029] querying notification status for Power Management... [Endpoint 2] 09:38:55.261 SERIAL « 0x010700137a00008312 (9 bytes) 09:38:55.262 SERIAL » [ACK] (0x06) 09:38:55.262 DRIVER « [REQ] [SendData] callback id: 122 transmit status: OK 09:38:55.283 SERIAL « 0x0110000400060a98805043cb9a67dfa42180 (18 bytes) 09:38:55.284 SERIAL » [ACK] (0x06) 09:38:55.285 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x5043cb9a67dfa421 09:38:55.304 SERIAL » 0x011d001306169881d2509c6a88bb3b09a3fceb506035d8f2b75b7796257b45 (31 bytes) 09:38:55.305 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 123 └─[SecurityCCCommandEncapsulation] │ nonce id: 80 └─[BatteryCCGet] 09:38:55.308 SERIAL « [ACK] (0x06) 09:38:55.315 SERIAL « 0x0104011301e8 (6 bytes) 09:38:55.316 SERIAL » [ACK] (0x06) 09:38:55.317 DRIVER « [RES] [SendData] was sent: true 09:38:55.340 SERIAL « 0x010700137b00000393 (9 bytes) 09:38:55.340 SERIAL » [ACK] (0x06) 09:38:55.341 DRIVER « [REQ] [SendData] callback id: 123 transmit status: OK 09:38:55.457 SERIAL « 0x0108000400060298402f (10 bytes) 09:38:55.457 SERIAL » [ACK] (0x06) 09:38:55.458 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:38:55.467 SERIAL » 0x01110013060a9880a87bf361e7dd1e072400af (19 bytes) 09:38:55.468 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xa87bf361e7dd1e07 09:38:55.470 SERIAL « [ACK] (0x06) 09:38:55.477 SERIAL « 0x0104011301e8 (6 bytes) 09:38:55.477 SERIAL » [ACK] (0x06) 09:38:55.478 DRIVER « [RES] [SendData] was sent: true 09:38:55.518 SERIAL « 0x011d00040006179881b5390a85fb6ef29beb868785a8071f6d4acf1b972983 (31 bytes) 09:38:55.519 SERIAL » [ACK] (0x06) 09:38:55.521 CNTRLR [Node 006] [~] [Battery] level: 89 => 89 [Endpoint 0] 09:38:55.522 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 0] 09:38:55.523 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[BatteryCCReport] level: 89 is low: false 09:38:55.528 SERIAL » 0x011000131d09600d00027104000800257ca3 (18 bytes) 09:38:55.529 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 124 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: Power Management 09:38:55.530 CNTRLR « [Node 006] received response for battery information: level: 89 09:38:55.531 CNTRLR [Node 006] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:38:55.585 SERIAL « [ACK] (0x06) 09:38:55.593 SERIAL « 0x0104011301e8 (6 bytes) 09:38:55.593 SERIAL » [ACK] (0x06) 09:38:55.595 DRIVER « [RES] [SendData] was sent: true 09:38:55.603 CNTRLR [Node 006] ZWavePlusCC: doing a partial interview... [Endpoint 1] 09:38:55.603 CNTRLR [Node 006] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 09:38:55.604 CNTRLR [Node 006] ThermostatModeCC: doing a partial interview... [Endpoint 1] 09:38:55.604 CNTRLR » [Node 006] querying current thermostat mode... [Endpoint 1] 09:38:55.656 SERIAL « 0x01090004001b033003ff26 (11 bytes) 09:38:55.657 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:38:55.657 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:38:55.658 SERIAL » [ACK] (0x06) 09:38:55.659 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:38:55.672 SERIAL « 0x01090004001b032001ff34 (11 bytes) 09:38:55.673 SERIAL » [ACK] (0x06) 09:38:55.674 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:38:55.675 CNTRLR [Node 027] treating BasicCC Set as a report 09:38:55.675 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:38:57.259 SERIAL « 0x010700137c0000ac3b (9 bytes) 09:38:57.260 SERIAL » [ACK] (0x06) 09:38:57.261 DRIVER « [REQ] [SendData] callback id: 124 transmit status: OK 09:38:57.350 SERIAL « 0x01130004001d0d600d02007105000000ff08fe00ea (21 bytes) 09:38:57.351 SERIAL » [ACK] (0x06) 09:38:57.352 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 09:38:57.358 SERIAL » 0x010900131f026007257dc7 (11 bytes) 09:38:57.358 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 125 └─[MultiChannelCCEndPointGet] 09:38:57.360 CNTRLR [Node 029] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 2] 54 09:38:57.361 CNTRLR » [Node 029] querying notification status for System... [Endpoint 2] 09:38:57.365 SERIAL « [ACK] (0x06) 09:38:57.367 SERIAL « 0x0104011301e8 (6 bytes) 09:38:57.367 SERIAL » [ACK] (0x06) 09:38:57.368 DRIVER « [RES] [SendData] was sent: true 09:38:57.438 SERIAL « 0x010700137d00000791 (9 bytes) 09:38:57.438 SERIAL » [ACK] (0x06) 09:38:57.439 DRIVER « [REQ] [SendData] callback id: 125 transmit status: OK 09:38:57.448 SERIAL « 0x010a0004001f0460084002c0 (12 bytes) 09:38:57.449 CNTRLR [Node 031] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:38:57.450 CNTRLR [Node 031] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 09:38:57.450 CNTRLR [Node 031] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:38:57.450 SERIAL » [ACK] (0x06) 09:38:57.451 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:38:57.454 SERIAL » 0x011000131d09600d00027104000900257ea0 (18 bytes) 09:38:57.454 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 126 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:38:57.455 CNTRLR [Node 031] The node is alive. 09:38:57.455 CNTRLR [Node 031] The node is ready to be used 09:38:57.457 CNTRLR « [Node 031] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: true 09:38:57.457 CNTRLR [Node 031] does not support EndPointFind, assuming that endpoints are sequenti al 09:38:57.457 CNTRLR » [Node 031] querying capabilities for endpoint #1... 09:38:57.461 SERIAL « [ACK] (0x06) 09:38:57.465 SERIAL « 0x0104011301e8 (6 bytes) 09:38:57.466 SERIAL » [ACK] (0x06) 09:38:57.467 DRIVER « [RES] [SendData] was sent: true 09:38:57.711 SERIAL « 0x010700137e0000099c (9 bytes) 09:38:57.711 SERIAL » [ACK] (0x06) 09:38:57.712 DRIVER « [REQ] [SendData] callback id: 126 transmit status: OK 09:38:57.742 SERIAL « 0x0112000400180c600d02003202213203440000f6 (20 bytes) 09:38:57.744 CNTRLR [Node 024] [~] [Meter] value[66049]: 138.9 => 83.6 [Endpoint 2] 09:38:57.745 CNTRLR [Node 024] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 2] 09:38:57.745 SERIAL » [ACK] (0x06) 09:38:57.747 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 83.6 time delta: 0 seconds 09:38:58.632 DRIVER The awake timeout for node 11 has elapsed. Assuming it is asleep. 09:38:58.633 CNTRLR [Node 011] The node is now asleep. 09:38:58.635 CNTRLR [Node 011] error during API call: ZWaveError: The node is asleep 09:38:58.635 CNTRLR [Node 011] compat query "Thermostat Setpoint"::get(1) 09:38:58.637 CNTRLR [Node 011] error during API call: ZWaveError: The node is asleep 09:38:58.638 CNTRLR [Node 011] compat query "Thermostat Setpoint"::get(1) 09:38:59.314 CNTRLR [Node 029] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:38:59.821 SERIAL » 0x011000131d09600d00027104000900257ea0 (18 bytes) 09:38:59.822 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 126 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:38:59.824 SERIAL « [ACK] (0x06) 09:38:59.830 SERIAL « 0x0104011301e8 (6 bytes) 09:38:59.831 SERIAL » [ACK] (0x06) 09:38:59.832 DRIVER « [RES] [SendData] was sent: true 09:39:01.303 SERIAL « 0x010700137e00009401 (9 bytes) 09:39:01.304 SERIAL » [ACK] (0x06) 09:39:01.305 DRIVER « [REQ] [SendData] callback id: 126 transmit status: OK 09:39:02.858 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 09:39:02.859 SERIAL » [ACK] (0x06) 09:39:02.861 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 09:39:02.863 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 09:39:02.909 CNTRLR [Node 029] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:39:03.295 SERIAL « 0x01090004001e033003ff23 (11 bytes) 09:39:03.297 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:39:03.298 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:39:03.299 SERIAL » [ACK] (0x06) 09:39:03.301 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:39:03.349 SERIAL « 0x01090004001e032001ff31 (11 bytes) 09:39:03.350 SERIAL » [ACK] (0x06) 09:39:03.351 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:39:03.353 CNTRLR [Node 030] treating BasicCC Set as a report 09:39:03.354 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:39:03.415 SERIAL » 0x011000131d09600d00027104000900257ea0 (18 bytes) 09:39:03.416 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 126 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:39:03.418 SERIAL « [ACK] (0x06) 09:39:03.424 SERIAL « 0x0104011301e8 (6 bytes) 09:39:03.425 SERIAL » [ACK] (0x06) 09:39:03.425 DRIVER « [RES] [SendData] was sent: true 09:39:04.915 SERIAL « 0x010700137e00009603 (9 bytes) 09:39:04.915 SERIAL » [ACK] (0x06) 09:39:04.916 DRIVER « [REQ] [SendData] callback id: 126 transmit status: OK 09:39:05.232 SERIAL « 0x01090004000803200100d8 (11 bytes) 09:39:05.232 SERIAL » [ACK] (0x06) 09:39:05.233 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:39:05.235 CNTRLR [Node 008] treating BasicCC Set as a report 09:39:05.236 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:39:06.526 SERIAL » 0x010a00131c03430201257fe3 (12 bytes) 09:39:06.526 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 127 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:39:06.527 CNTRLR [Node 029] Interview attempt 4/5 failed, retrying in 20000 ms... 09:39:06.529 SERIAL « [ACK] (0x06) 09:39:06.535 SERIAL « 0x0104011301e8 (6 bytes) 09:39:06.536 SERIAL » [ACK] (0x06) 09:39:06.537 DRIVER « [RES] [SendData] was sent: true 09:39:07.900 SERIAL « 0x0112000400180c600d02003202213204cc000079 (20 bytes) 09:39:07.902 CNTRLR [Node 024] [~] [Meter] value[66049]: 83.6 => 122.8 [Endpoint 2] 09:39:07.904 CNTRLR [Node 024] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 2] 09:39:07.905 SERIAL » [ACK] (0x06) 09:39:07.907 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 122.8 time delta: 0 seconds 09:39:07.942 SERIAL « 0x010700137f00008d19 (9 bytes) 09:39:07.942 SERIAL » [ACK] (0x06) 09:39:07.944 DRIVER « [REQ] [SendData] callback id: 127 transmit status: OK 09:39:08.024 SERIAL « 0x010c0004001c06430301220064ea (14 bytes) 09:39:08.025 CNTRLR [Node 028] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 0] 09:39:08.027 CNTRLR [Node 028] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 09:39:08.027 SERIAL » [ACK] (0x06) 09:39:08.028 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 09:39:08.030 SERIAL » 0x010a0013180370051b258036 (12 bytes) 09:39:08.031 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 128 └─[ConfigurationCCGet] parameter #: 27 09:39:08.031 CNTRLR « [Node 028] received current value of setpoint Heating: 10 °C 09:39:08.031 CNTRLR [Node 028] [~] [Thermostat Setpoint] interviewComplete [Endpoint 0] [internal] : true => true 09:39:08.063 SERIAL « [ACK] (0x06) 09:39:08.067 SERIAL « 0x0104011301e8 (6 bytes) 09:39:08.068 SERIAL » [ACK] (0x06) 09:39:08.069 DRIVER « [RES] [SendData] was sent: true 09:39:08.070 CNTRLR [Node 028] ConfigurationCC: Loading configuration parameters from device confi g 09:39:08.076 CNTRLR [Node 028] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:39:08.076 CNTRLR [Node 028] [Configuration] 1: metadata updated 09:39:08.078 CNTRLR [Node 028] [Configuration] 2: metadata updated 09:39:08.079 CNTRLR [Node 028] [Configuration] 3: metadata updated 09:39:08.080 CNTRLR [Node 028] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:39:08.080 CNTRLR » [Node 028] querying parameter #1 value... 09:39:08.112 SERIAL « 0x010700138000000863 (9 bytes) 09:39:08.112 SERIAL » [ACK] (0x06) 09:39:08.113 DRIVER « [REQ] [SendData] callback id: 128 transmit status: OK 09:39:08.126 SERIAL « 0x010b000400180570061b010f8e (13 bytes) 09:39:08.131 CNTRLR [Node 024] [~] [Configuration] 27: 15 => 15 09:39:08.133 SERIAL » [ACK] (0x06) 09:39:08.133 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 27 value size: 1 value: 15 09:39:08.138 SERIAL » 0x010a00131a0370052b258105 (12 bytes) 09:39:08.138 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 129 └─[ConfigurationCCGet] parameter #: 43 09:39:08.138 CNTRLR « [Node 024] parameter #27 has value: 15 09:39:08.139 CNTRLR » [Node 024] querying parameter #28 value... 09:39:08.141 SERIAL « [ACK] (0x06) 09:39:08.146 SERIAL « 0x0104011301e8 (6 bytes) 09:39:08.146 SERIAL » [ACK] (0x06) 09:39:08.146 DRIVER « [RES] [SendData] was sent: true 09:39:08.163 SERIAL « 0x010700138100000369 (9 bytes) 09:39:08.164 SERIAL » [ACK] (0x06) 09:39:08.164 DRIVER « [REQ] [SendData] callback id: 129 transmit status: OK 09:39:08.174 SERIAL « 0x010b0004001a0570062b010ab9 (13 bytes) 09:39:08.179 CNTRLR [Node 026] [~] [Configuration] 43: 10 => 10 09:39:08.181 SERIAL » [ACK] (0x06) 09:39:08.181 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 10 09:39:08.186 SERIAL » 0x010900130602984025829e (11 bytes) 09:39:08.186 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 130 └─[SecurityCCNonceGet] 09:39:08.187 CNTRLR « [Node 026] parameter #43 has value: 10 09:39:08.187 CNTRLR » [Node 026] querying parameter #44 value... 09:39:08.196 SERIAL « [ACK] (0x06) 09:39:08.198 SERIAL « 0x0104011301e8 (6 bytes) 09:39:08.199 SERIAL » [ACK] (0x06) 09:39:08.201 DRIVER « [RES] [SendData] was sent: true 09:39:09.505 SERIAL « 0x0107001382000084ed (9 bytes) 09:39:09.505 SERIAL » [ACK] (0x06) 09:39:09.506 DRIVER « [REQ] [SendData] callback id: 130 transmit status: OK 09:39:09.527 SERIAL « 0x0110000400060a98805dba5613b8cfd4e31d (18 bytes) 09:39:09.528 SERIAL » [ACK] (0x06) 09:39:09.529 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x5dba5613b8cfd4e3 09:39:09.533 SERIAL » 0x01210013061a98819fababb358cb9abc96aa85bac7e0085d0c2ca474afab97d72 (35 bytes) 58332 09:39:09.534 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 131 └─[SecurityCCCommandEncapsulation] │ nonce id: 93 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:39:09.537 SERIAL « [ACK] (0x06) 09:39:09.544 SERIAL « 0x0104011301e8 (6 bytes) 09:39:09.544 SERIAL » [ACK] (0x06) 09:39:09.545 DRIVER « [RES] [SendData] was sent: true 09:39:09.569 SERIAL « 0x01070013830000036b (9 bytes) 09:39:09.569 SERIAL » [ACK] (0x06) 09:39:09.570 DRIVER « [REQ] [SendData] callback id: 131 transmit status: OK 09:39:09.686 SERIAL « 0x0108000400060298402f (10 bytes) 09:39:09.686 SERIAL » [ACK] (0x06) 09:39:09.687 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:39:09.700 SERIAL » 0x01110013060a9880954cf0889702e89d24008c (19 bytes) 09:39:09.700 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x954cf0889702e89d 09:39:09.703 SERIAL « [ACK] (0x06) 09:39:09.709 SERIAL « 0x0104011301e8 (6 bytes) 09:39:09.710 SERIAL » [ACK] (0x06) 09:39:09.710 DRIVER « [RES] [SendData] was sent: true 09:39:09.752 SERIAL « 0x0121000400061b98819539833af87b8560611f1c82dabdc156950c2f95ccb0dd2 (35 bytes) 80116 09:39:09.753 SERIAL » [ACK] (0x06) 09:39:09.755 CNTRLR [Node 006] [~] [Thermostat Mode] mode: 0 => 0 [Endpoint 1] 09:39:09.756 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Off 09:39:09.761 SERIAL » 0x010a00131f03600901258433 (12 bytes) 09:39:09.762 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 132 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:39:09.763 CNTRLR « [Node 006] received current thermostat mode: Off [Endpoint 1] 09:39:09.764 CNTRLR [Node 006] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 1] [internal] ue => true 09:39:09.823 SERIAL « [ACK] (0x06) 09:39:09.824 SERIAL « 0x0104011301e8 (6 bytes) 09:39:09.824 SERIAL » [ACK] (0x06) 09:39:09.827 DRIVER « [RES] [SendData] was sent: true 09:39:09.829 SERIAL « 0x01070013840000026d (9 bytes) 09:39:09.830 SERIAL » [ACK] (0x06) 09:39:09.831 DRIVER « [REQ] [SendData] callback id: 132 transmit status: OK 09:39:09.833 CNTRLR [Node 006] ThermostatSetpointCC: doing a partial interview... [Endpoint 1] 09:39:09.834 CNTRLR » [Node 006] querying current value of setpoint Heating... [Endpoint 1] 09:39:09.837 SERIAL « 0x010c0004001f06600a01100125b1 (14 bytes) 09:39:09.838 CNTRLR [Node 031] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 1] [internal] 7 09:39:09.838 SERIAL » [ACK] (0x06) 09:39:09.839 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:39:09.842 SERIAL » 0x010a00131c0370050125852d (12 bytes) 09:39:09.843 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 133 └─[ConfigurationCCGet] parameter #: 1 09:39:09.843 CNTRLR « [Node 031] received response for endpoint capabilities (#1): generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 09:39:09.843 CNTRLR [Node 031] all endpoints idendical, skipping capability query for endpoint #2. .. 09:39:09.844 CNTRLR [Node 031] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 2] [internal] 7 09:39:09.844 CNTRLR [Node 031] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:39:09.845 CNTRLR [Node 031] AssociationCC: doing a partial interview... 09:39:09.845 CNTRLR [Node 031] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 09:39:09.845 CNTRLR [Node 031] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:39:09.846 CNTRLR [Node 031] BinarySwitchCC: doing a partial interview... [Endpoint 1] 09:39:09.846 CNTRLR » [Node 031] querying Binary Switch state... [Endpoint 1] 09:39:09.850 SERIAL « [ACK] (0x06) 09:39:09.851 SERIAL « 0x0104011301e8 (6 bytes) 09:39:09.852 SERIAL » [ACK] (0x06) 09:39:09.852 DRIVER « [RES] [SendData] was sent: true 09:39:11.206 SERIAL « 0x0107001385000088e6 (9 bytes) 09:39:11.207 SERIAL » [ACK] (0x06) 09:39:11.208 DRIVER « [REQ] [SendData] callback id: 133 transmit status: OK 09:39:11.329 SERIAL « 0x010e0004001c0870060104000000f062 (16 bytes) 09:39:11.341 CNTRLR [Node 028] [~] [Configuration] 1: 240 => 240 09:39:11.343 SERIAL » [ACK] (0x06) 09:39:11.344 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 4 value: 240 09:39:11.351 SERIAL » 0x010a0013180370051c258637 (12 bytes) 09:39:11.352 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 134 └─[ConfigurationCCGet] parameter #: 28 09:39:11.352 CNTRLR « [Node 028] parameter #1 has value: 240 09:39:11.353 CNTRLR » [Node 028] querying parameter #2 value... 09:39:11.359 SERIAL « [ACK] (0x06) 09:39:11.361 SERIAL « 0x0104011301e8 (6 bytes) 09:39:11.362 SERIAL » [ACK] (0x06) 09:39:11.363 DRIVER « [RES] [SendData] was sent: true 09:39:11.422 SERIAL « 0x01070013860000076a (9 bytes) 09:39:11.423 SERIAL » [ACK] (0x06) 09:39:11.424 DRIVER « [REQ] [SendData] callback id: 134 transmit status: OK 09:39:11.436 SERIAL « 0x010b000400180570061c010086 (13 bytes) 09:39:11.441 CNTRLR [Node 024] [~] [Configuration] 28: 0 => 0 09:39:11.442 SERIAL » [ACK] (0x06) 09:39:11.442 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 28 value size: 1 value: 0 09:39:11.445 SERIAL » 0x010a00131a0370052c258704 (12 bytes) 09:39:11.446 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 135 └─[ConfigurationCCGet] parameter #: 44 09:39:11.446 CNTRLR « [Node 024] parameter #28 has value: 0 09:39:11.446 CNTRLR » [Node 024] querying parameter #29 value... 09:39:11.451 SERIAL « [ACK] (0x06) 09:39:11.455 SERIAL « 0x0104011301e8 (6 bytes) 09:39:11.455 SERIAL » [ACK] (0x06) 09:39:11.456 DRIVER « [RES] [SendData] was sent: true 09:39:11.471 SERIAL « 0x01070013870000026e (9 bytes) 09:39:11.471 SERIAL » [ACK] (0x06) 09:39:11.472 DRIVER « [REQ] [SendData] callback id: 135 transmit status: OK 09:39:11.482 SERIAL « 0x010b0004001a0570062c0100b4 (13 bytes) 09:39:11.487 CNTRLR [Node 026] [~] [Configuration] 44: 0 => 0 09:39:11.487 SERIAL » [ACK] (0x06) 09:39:11.488 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 44 value size: 1 value: 0 09:39:11.493 SERIAL » 0x0109001306029840258894 (11 bytes) 09:39:11.493 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 136 └─[SecurityCCNonceGet] 09:39:11.493 CNTRLR « [Node 026] parameter #44 has value: 0 09:39:11.494 CNTRLR » [Node 026] querying parameter #50 value... 09:39:11.497 SERIAL « [ACK] (0x06) 09:39:11.501 SERIAL « 0x0104011301e8 (6 bytes) 09:39:11.502 SERIAL » [ACK] (0x06) 09:39:11.502 DRIVER « [RES] [SendData] was sent: true 09:39:11.583 SERIAL « 0x010c00041003063105042208ec14 (14 bytes) 09:39:11.584 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:39:11.584 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 91.4 => 228.4 [Endpoint 0] 09:39:11.585 SERIAL » [ACK] (0x06) 09:39:11.586 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 228.4 09:39:11.591 SERIAL « 0x010c00041003063105042208ec14 (14 bytes) 09:39:11.592 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:39:11.592 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 228.4 => 228.4 [Endpoint 0] 09:39:11.593 SERIAL » [ACK] (0x06) 09:39:11.594 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 228.4 09:39:11.629 SERIAL « 0x010c00041003063105042208ec14 (14 bytes) 09:39:11.629 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:39:11.630 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 228.4 => 228.4 [Endpoint 0] 09:39:11.630 SERIAL » [ACK] (0x06) 09:39:11.631 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 228.4 09:39:12.779 SERIAL « 0x010c00041003063105042208ec14 (14 bytes) 09:39:12.780 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:39:12.782 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 228.4 => 228.4 [Endpoint 0] 09:39:12.783 SERIAL » [ACK] (0x06) 09:39:12.785 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 228.4 09:39:13.972 SERIAL « 0x01070013880000f89b (9 bytes) 09:39:13.973 SERIAL » [ACK] (0x06) 09:39:13.973 DRIVER « [REQ] [SendData] callback id: 136 transmit status: OK 09:39:14.002 SERIAL « 0x0110000400060a98808086c664e043f7d8d7 (18 bytes) 09:39:14.002 SERIAL » [ACK] (0x06) 09:39:14.003 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x8086c664e043f7d8 09:39:14.006 SERIAL » 0x01220013061b9881da1e5af2422ed2672235b56b54330d3f80cdc9137996ca028 (36 bytes) 425897b 09:39:14.007 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 137 └─[SecurityCCCommandEncapsulation] │ nonce id: 128 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:39:14.010 SERIAL « [ACK] (0x06) 09:39:14.017 SERIAL « 0x0104011301e8 (6 bytes) 09:39:14.017 SERIAL » [ACK] (0x06) 09:39:14.018 DRIVER « [RES] [SendData] was sent: true 09:39:14.032 SERIAL « 0x0110000400060a98802c34ae824aef6fc4c5 (18 bytes) 09:39:14.032 SERIAL » [ACK] (0x06) 09:39:14.033 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x2c34ae824aef6fc4 09:39:14.061 SERIAL « 0x010700138900000567 (9 bytes) 09:39:14.061 SERIAL » [ACK] (0x06) 09:39:14.062 DRIVER « [REQ] [SendData] callback id: 137 transmit status: OK 09:39:14.185 SERIAL « 0x0108000400060298402f (10 bytes) 09:39:14.185 SERIAL » [ACK] (0x06) 09:39:14.186 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:39:14.190 SERIAL » 0x01110013060a9880cd953279430e15542400d2 (19 bytes) 09:39:14.190 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xcd953279430e1554 09:39:14.192 SERIAL « [ACK] (0x06) 09:39:14.199 SERIAL « 0x0104011301e8 (6 bytes) 09:39:14.199 SERIAL » [ACK] (0x06) 09:39:14.199 DRIVER « [RES] [SendData] was sent: true 09:39:14.242 SERIAL « 0x0124000400061e9881021e156d044719d5e7e921edb717a79b068bc5cdbf3fe06 (38 bytes) ec3626f406e 09:39:14.243 SERIAL » [ACK] (0x06) 09:39:14.244 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 1] 09:39:14.245 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 09:39:14.245 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 09:39:14.248 SERIAL » 0x010d00131f06600d00012502258a1c (15 bytes) 09:39:14.248 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 138 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 09:39:14.249 CNTRLR « [Node 006] received current value of setpoint Heating: 10 °C [Endpoint 1] 09:39:14.249 CNTRLR [Node 006] [~] [Thermostat Setpoint] interviewComplete [Endpoint 1] [internal] : true => true 09:39:14.280 SERIAL « [ACK] (0x06) 09:39:14.281 SERIAL « 0x0104011301e8 (6 bytes) 09:39:14.281 SERIAL » [ACK] (0x06) 09:39:14.283 DRIVER « [RES] [SendData] was sent: true 09:39:14.285 CNTRLR [Node 006] NotificationCC: doing a partial interview... [Endpoint 1] 09:39:14.285 CNTRLR » [Node 006] querying notification status for Power Management... [Endpoint 1] 09:39:14.289 SERIAL « 0x010700138a00000362 (9 bytes) 09:39:14.290 SERIAL » [ACK] (0x06) 09:39:14.291 DRIVER « [REQ] [SendData] callback id: 138 transmit status: OK 09:39:14.294 SERIAL « 0x010d0004001f07600d0100250300a4 (15 bytes) 09:39:14.296 CNTRLR [Node 031] [~] [Binary Switch] currentValue: false => false [Endpoint 1] 09:39:14.297 SERIAL » [ACK] (0x06) 09:39:14.298 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: false 09:39:14.303 SERIAL » 0x010a00131c03700502258b20 (12 bytes) 09:39:14.304 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 139 └─[ConfigurationCCGet] parameter #: 2 09:39:14.305 CNTRLR « [Node 031] received Binary Switch state: [Endpoint 1] current value: false 09:39:14.305 CNTRLR [Node 031] [~] [Binary Switch] interviewComplete: true [Endpoint 1] [internal] => true 09:39:14.306 CNTRLR [Node 031] BinarySwitchCC: doing a partial interview... [Endpoint 2] 09:39:14.307 CNTRLR » [Node 031] querying Binary Switch state... [Endpoint 2] 09:39:14.311 SERIAL « [ACK] (0x06) 09:39:14.314 SERIAL « 0x0104011301e8 (6 bytes) 09:39:14.314 SERIAL » [ACK] (0x06) 09:39:14.315 DRIVER « [RES] [SendData] was sent: true 09:39:15.702 SERIAL « 0x010700138b00008cec (9 bytes) 09:39:15.703 SERIAL » [ACK] (0x06) 09:39:15.703 DRIVER « [REQ] [SendData] callback id: 139 transmit status: OK 09:39:15.823 SERIAL « 0x010e0004001c08700602040000000190 (16 bytes) 09:39:15.835 CNTRLR [Node 028] [~] [Configuration] 2: 1 => 1 09:39:15.838 SERIAL » [ACK] (0x06) 09:39:15.839 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 4 value: 1 09:39:15.845 SERIAL » 0x010a0013180370051d258c3c (12 bytes) 09:39:15.846 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 140 └─[ConfigurationCCGet] parameter #: 29 09:39:15.846 CNTRLR « [Node 028] parameter #2 has value: 1 09:39:15.847 CNTRLR » [Node 028] querying parameter #3 value... 09:39:15.854 SERIAL « [ACK] (0x06) 09:39:15.859 SERIAL « 0x0104011301e8 (6 bytes) 09:39:15.859 SERIAL » [ACK] (0x06) 09:39:15.860 DRIVER « [RES] [SendData] was sent: true 09:39:15.912 SERIAL « 0x010700138c00000760 (9 bytes) 09:39:15.912 SERIAL » [ACK] (0x06) 09:39:15.913 DRIVER « [REQ] [SendData] callback id: 140 transmit status: OK 09:39:15.926 SERIAL « 0x010b000400180570061d010087 (13 bytes) 09:39:15.936 CNTRLR [Node 024] [~] [Configuration] 29: 0 => 0 09:39:15.937 SERIAL » [ACK] (0x06) 09:39:15.938 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 29 value size: 1 value: 0 09:39:15.942 SERIAL » 0x010a00131a03700532258d10 (12 bytes) 09:39:15.942 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 141 └─[ConfigurationCCGet] parameter #: 50 09:39:15.943 CNTRLR « [Node 024] parameter #29 has value: 0 09:39:15.943 CNTRLR » [Node 024] querying parameter #30 value... 09:39:15.947 SERIAL « [ACK] (0x06) 09:39:15.952 SERIAL « 0x0104011301e8 (6 bytes) 09:39:15.952 SERIAL » [ACK] (0x06) 09:39:15.953 DRIVER « [RES] [SendData] was sent: true 09:39:15.967 SERIAL « 0x010700138d00000264 (9 bytes) 09:39:15.968 SERIAL » [ACK] (0x06) 09:39:15.968 DRIVER « [REQ] [SendData] callback id: 141 transmit status: OK 09:39:15.978 SERIAL « 0x010b0004001a057006320100aa (13 bytes) 09:39:15.985 CNTRLR [Node 026] [~] [Configuration] 50: 0 => 0 09:39:15.986 SERIAL » [ACK] (0x06) 09:39:15.987 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 0 09:39:15.991 SERIAL » 0x01240013061d98812815bab921f18eb026a0d8151d0d1bde049e2c3c095422e0c (38 bytes) a6581258e14 09:39:15.992 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 142 └─[SecurityCCCommandEncapsulation] │ nonce id: 44 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: Power Management 09:39:15.993 CNTRLR « [Node 026] parameter #50 has value: 0 09:39:15.993 CNTRLR [Node 026] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 09:39:16.032 SERIAL « [ACK] (0x06) 09:39:16.033 SERIAL « 0x0104011301e8 (6 bytes) 09:39:16.034 SERIAL » [ACK] (0x06) 09:39:16.035 DRIVER « [RES] [SendData] was sent: true 09:39:16.037 CNTRLR [Node 026] ProtectionCC: doing a partial interview... 09:39:16.037 CNTRLR » [Node 026] querying protection status... 09:39:17.320 SERIAL « 0x010700138e000084e1 (9 bytes) 09:39:17.321 SERIAL » [ACK] (0x06) 09:39:17.321 DRIVER « [REQ] [SendData] callback id: 142 transmit status: OK 09:39:18.926 CNTRLR [Node 006] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:39:19.430 SERIAL » 0x0109001306029840258f93 (11 bytes) 09:39:19.430 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 143 └─[SecurityCCNonceGet] 09:39:19.432 SERIAL « [ACK] (0x06) 09:39:19.438 SERIAL « 0x0104011301e8 (6 bytes) 09:39:19.438 SERIAL » [ACK] (0x06) 09:39:19.439 DRIVER « [RES] [SendData] was sent: true 09:39:20.659 SERIAL « 0x010700138f00007a1e (9 bytes) 09:39:20.659 SERIAL » [ACK] (0x06) 09:39:20.660 DRIVER « [REQ] [SendData] callback id: 143 transmit status: OK 09:39:20.681 SERIAL « 0x0110000400060a9880813e9e5130d547210c (18 bytes) 09:39:20.682 SERIAL » [ACK] (0x06) 09:39:20.682 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x813e9e5130d54721 09:39:20.685 SERIAL » 0x01240013061d988139faf6939df6cb74da62ed1360b85e90a55d81c91c1f467da (38 bytes) 7f9d2258e47 09:39:20.686 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 142 └─[SecurityCCCommandEncapsulation] │ nonce id: 129 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: Power Management 09:39:20.689 SERIAL « [ACK] (0x06) 09:39:20.696 SERIAL « 0x0104011301e8 (6 bytes) 09:39:20.696 SERIAL » [ACK] (0x06) 09:39:20.697 DRIVER « [RES] [SendData] was sent: true 09:39:20.722 SERIAL « 0x010700138e00000461 (9 bytes) 09:39:20.723 SERIAL » [ACK] (0x06) 09:39:20.723 DRIVER « [REQ] [SendData] callback id: 142 transmit status: OK 09:39:20.745 SERIAL « 0x0108000400060298402f (10 bytes) 09:39:20.745 SERIAL » [ACK] (0x06) 09:39:20.745 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:39:20.754 SERIAL » 0x01110013060a98805bbf3c494e9c4f102400d1 (19 bytes) 09:39:20.754 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x5bbf3c494e9c4f10 09:39:20.756 SERIAL « [ACK] (0x06) 09:39:20.762 SERIAL « 0x0104011301e8 (6 bytes) 09:39:20.763 SERIAL » [ACK] (0x06) 09:39:20.763 DRIVER « [RES] [SendData] was sent: true 09:39:20.807 SERIAL « 0x012700040006219881d950f73f027940b26ea31f99a8dba64fce611995e9045bc (41 bytes) 3e25ff075e8e6c65d 09:39:20.808 SERIAL » [ACK] (0x06) 09:39:20.809 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 09:39:20.811 SERIAL » 0x010d00131f06600d00022502259005 (15 bytes) 09:39:20.812 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 144 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[BinarySwitchCCGet] 09:39:20.812 CNTRLR [Node 006] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 1] 54 09:39:20.813 CNTRLR » [Node 006] querying notification status for System... [Endpoint 1] 09:39:20.816 SERIAL « [ACK] (0x06) 09:39:20.820 SERIAL « 0x0104011301e8 (6 bytes) 09:39:20.820 SERIAL » [ACK] (0x06) 09:39:20.821 DRIVER « [RES] [SendData] was sent: true 09:39:20.838 SERIAL « 0x010700139000000279 (9 bytes) 09:39:20.838 SERIAL » [ACK] (0x06) 09:39:20.839 DRIVER « [REQ] [SendData] callback id: 144 transmit status: OK 09:39:20.849 SERIAL « 0x010d0004001f07600d0200250300a7 (15 bytes) 09:39:20.850 CNTRLR [Node 031] [~] [Binary Switch] currentValue: false => false [Endpoint 2] 09:39:20.850 SERIAL » [ACK] (0x06) 09:39:20.851 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BinarySwitchCCReport] current value: false 09:39:20.854 SERIAL » 0x010a00131c0370050325913b (12 bytes) 09:39:20.855 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 145 └─[ConfigurationCCGet] parameter #: 3 09:39:20.855 CNTRLR « [Node 031] received Binary Switch state: [Endpoint 2] current value: false 09:39:20.856 CNTRLR [Node 031] [~] [Binary Switch] interviewComplete: true [Endpoint 2] [internal] => true 09:39:20.888 SERIAL « [ACK] (0x06) 09:39:20.889 SERIAL « 0x0104011301e8 (6 bytes) 09:39:20.889 SERIAL » [ACK] (0x06) 09:39:20.891 DRIVER « [RES] [SendData] was sent: true 09:39:20.894 CNTRLR [Node 031] BinarySwitchCC: doing a partial interview... 09:39:20.894 CNTRLR » [Node 031] querying Binary Switch state... 09:39:22.252 SERIAL « 0x010700139100008cf6 (9 bytes) 09:39:22.253 SERIAL » [ACK] (0x06) 09:39:22.254 DRIVER « [REQ] [SendData] callback id: 145 transmit status: OK 09:39:22.372 SERIAL « 0x010e0004001c08700603040000000090 (16 bytes) 09:39:22.384 CNTRLR [Node 028] [~] [Configuration] 3: 0 => 0 09:39:22.387 SERIAL » [ACK] (0x06) 09:39:22.388 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 4 value: 0 09:39:22.394 SERIAL » 0x010a0013180370051e259221 (12 bytes) 09:39:22.395 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 146 └─[ConfigurationCCGet] parameter #: 30 09:39:22.395 CNTRLR « [Node 028] parameter #3 has value: 0 09:39:22.396 CNTRLR [Node 028] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 09:39:22.460 SERIAL « [ACK] (0x06) 09:39:22.466 SERIAL « 0x0104011301e8 (6 bytes) 09:39:22.466 SERIAL » [ACK] (0x06) 09:39:22.468 DRIVER « [RES] [SendData] was sent: true 09:39:22.472 CNTRLR [Node 028] ProtectionCC: doing a partial interview... 09:39:22.472 CNTRLR » [Node 028] querying protection status... 09:39:22.476 SERIAL « 0x010700139200000871 (9 bytes) 09:39:22.477 SERIAL » [ACK] (0x06) 09:39:22.478 DRIVER « [REQ] [SendData] callback id: 146 transmit status: OK 09:39:22.486 SERIAL « 0x010b000400180570061e010084 (13 bytes) 09:39:22.495 CNTRLR [Node 024] [~] [Configuration] 30: 0 => 0 09:39:22.496 SERIAL » [ACK] (0x06) 09:39:22.497 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 0 09:39:22.500 SERIAL » 0x010900131a02750225933c (11 bytes) 09:39:22.500 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 147 └─[ProtectionCCGet] 09:39:22.500 CNTRLR « [Node 024] parameter #30 has value: 0 09:39:22.500 CNTRLR » [Node 024] querying parameter #31 value... 09:39:22.503 SERIAL « [ACK] (0x06) 09:39:22.508 SERIAL « 0x0104011301e8 (6 bytes) 09:39:22.509 SERIAL » [ACK] (0x06) 09:39:22.510 DRIVER « [RES] [SendData] was sent: true 09:39:22.525 SERIAL « 0x01070013930000027a (9 bytes) 09:39:22.525 SERIAL » [ACK] (0x06) 09:39:22.526 DRIVER « [REQ] [SendData] callback id: 147 transmit status: OK 09:39:22.538 SERIAL « 0x010a0004001a047503000099 (12 bytes) 09:39:22.539 CNTRLR [Node 026] [~] [Protection] local: 0 => 0 [Endpoint 0] 09:39:22.539 CNTRLR [Node 026] [~] [Protection] rf: 0 => 0 [Endpoint 0] 09:39:22.540 SERIAL » [ACK] (0x06) 09:39:22.541 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 09:39:22.546 SERIAL » 0x0109001306029840259488 (11 bytes) 09:39:22.546 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 148 └─[SecurityCCNonceGet] 09:39:22.547 CNTRLR « [Node 026] received protection status: local: Unprotected rf Unprotected 09:39:22.547 CNTRLR [Node 026] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 09:39:22.548 CNTRLR [Node 026] FibaroVenetianBlindCC: doing a partial interview... 09:39:22.548 CNTRLR » [Node 026] Requesting venetian blind position and tilt... 09:39:22.555 SERIAL « [ACK] (0x06) 09:39:22.556 SERIAL « 0x0104011301e8 (6 bytes) 09:39:22.556 SERIAL » [ACK] (0x06) 09:39:22.557 DRIVER « [RES] [SendData] was sent: true 09:39:23.804 SERIAL « 0x010700139400007e01 (9 bytes) 09:39:23.805 SERIAL » [ACK] (0x06) 09:39:23.806 DRIVER « [REQ] [SendData] callback id: 148 transmit status: OK 09:39:23.827 SERIAL « 0x0110000400060a9880803a990b0fb9082940 (18 bytes) 09:39:23.827 SERIAL » [ACK] (0x06) 09:39:23.828 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x803a990b0fb90829 09:39:23.835 SERIAL » 0x01240013061d98817c8468cc842ae765ccedbd735243401cd83780bdfb3269a5c (38 bytes) 2fc37259576 09:39:23.835 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 149 └─[SecurityCCCommandEncapsulation] │ nonce id: 128 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: System 09:39:23.839 SERIAL « [ACK] (0x06) 09:39:23.846 SERIAL « 0x0104011301e8 (6 bytes) 09:39:23.847 SERIAL » [ACK] (0x06) 09:39:23.847 DRIVER « [RES] [SendData] was sent: true 09:39:23.872 SERIAL « 0x01070013950000047a (9 bytes) 09:39:23.873 SERIAL » [ACK] (0x06) 09:39:23.874 DRIVER « [REQ] [SendData] callback id: 149 transmit status: OK 09:39:23.895 SERIAL « 0x0108000400060298402f (10 bytes) 09:39:23.895 SERIAL » [ACK] (0x06) 09:39:23.896 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:39:23.904 SERIAL » 0x01110013060a98805dba132babbce8372400da (19 bytes) 09:39:23.904 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x5dba132babbce837 09:39:23.906 SERIAL « [ACK] (0x06) 09:39:23.913 SERIAL « 0x0104011301e8 (6 bytes) 09:39:23.913 SERIAL » [ACK] (0x06) 09:39:23.914 DRIVER « [RES] [SendData] was sent: true 09:39:23.957 SERIAL « 0x012700040006219881a082dff7b6aeebff6fbf03deaca06638785e1fdc3b4d5d1 (41 bytes) cfd0b62860da7c617 09:39:23.958 SERIAL » [ACK] (0x06) 09:39:23.960 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: System notification status: 255 notification event: Unknown (0xfe) 09:39:23.965 SERIAL » 0x010c00131a0591010f26022596f7 (14 bytes) 09:39:23.966 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 150 └─[FibaroVenetianBlindCCGet] payload: 0x0f2602 09:39:23.966 CNTRLR [Node 006] [~] [Notification] System[unknown]: 254 => 254 [Endpoint 1] 09:39:23.968 CNTRLR [Node 006] [~] [Notification] interviewComplete: true [Endpoint 1] [internal] => true 09:39:24.012 SERIAL « [ACK] (0x06) 09:39:24.016 SERIAL « 0x0104011301e8 (6 bytes) 09:39:24.016 SERIAL » [ACK] (0x06) 09:39:24.018 DRIVER « [RES] [SendData] was sent: true 09:39:24.020 SERIAL « 0x01070013960000037e (9 bytes) 09:39:24.021 SERIAL » [ACK] (0x06) 09:39:24.022 CNTRLR [Node 006] ProtectionCC: doing a partial interview... 09:39:24.022 CNTRLR » [Node 006] querying protection status... 09:39:24.026 DRIVER « [REQ] [SendData] callback id: 150 transmit status: OK 09:39:24.029 SERIAL « 0x010e0004001a0891010f26030263003c (16 bytes) 09:39:24.031 CNTRLR [Node 026] [Manufacturer Proprietary] fibaro[venetianBlindsPositi [Endpoint 0] on]: metadata updated 09:39:24.032 CNTRLR [Node 026] [~] [Manufacturer Proprietary] fibaro[venetianBlindsPo [Endpoint 0] sition]: 99 => 99 09:39:24.033 SERIAL » [ACK] (0x06) 09:39:24.034 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[FibaroVenetianBlindCCReport] position: 99 09:39:24.038 SERIAL » 0x010900131f02250225976d (11 bytes) 09:39:24.038 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 151 └─[BinarySwitchCCGet] 09:39:24.039 CNTRLR « [Node 026] received venetian blind state: position: 99 tilt: undefined 09:39:24.039 CNTRLR [Node 026] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 09:39:24.040 CNTRLR [Node 026] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 09:39:24.040 CNTRLR [Node 026] MultiChannelAssociationCC: doing a partial interview... 09:39:24.040 CNTRLR » [Node 026] querying multi channel association group #1... 09:39:24.044 SERIAL « [ACK] (0x06) 09:39:24.047 SERIAL « 0x0104011301e8 (6 bytes) 09:39:24.047 SERIAL » [ACK] (0x06) 09:39:24.048 DRIVER « [RES] [SendData] was sent: true 09:39:24.063 SERIAL « 0x01070013970000037f (9 bytes) 09:39:24.064 SERIAL » [ACK] (0x06) 09:39:24.064 DRIVER « [REQ] [SendData] callback id: 151 transmit status: OK 09:39:24.074 SERIAL « 0x01090004001f03250300c8 (11 bytes) 09:39:24.075 CNTRLR [Node 031] [~] [Binary Switch] currentValue: false => false [Endpoint 0] 09:39:24.075 SERIAL » [ACK] (0x06) 09:39:24.076 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 09:39:24.079 SERIAL » 0x010a00131a038e02012598cf (12 bytes) 09:39:24.079 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 152 └─[MultiChannelAssociationCCGet] group id: 1 09:39:24.080 CNTRLR « [Node 031] received Binary Switch state: current value: false 09:39:24.084 CNTRLR [Node 031] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 09:39:24.084 CNTRLR [Node 031] ConfigurationCC: Loading configuration parameters from device confi g 09:39:24.099 CNTRLR [Node 031] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:39:24.100 CNTRLR [Node 031] [Configuration] 1: metadata updated 09:39:24.101 CNTRLR [Node 031] [Configuration] 3: metadata updated 09:39:24.102 CNTRLR [Node 031] [Configuration] 4: metadata updated 09:39:24.104 CNTRLR [Node 031] [Configuration] 5: metadata updated 09:39:24.105 CNTRLR [Node 031] [Configuration] 6: metadata updated 09:39:24.107 CNTRLR [Node 031] [Configuration] 7: metadata updated 09:39:24.108 CNTRLR [Node 031] [Configuration] 13: metadata updated 09:39:24.109 CNTRLR [Node 031] [Configuration] 14: metadata updated 09:39:24.111 CNTRLR [Node 031] [Configuration] 15: metadata updated 09:39:24.112 CNTRLR [Node 031] [Configuration] 16: metadata updated 09:39:24.113 CNTRLR [Node 031] [Configuration] 30: metadata updated 09:39:24.114 CNTRLR [Node 031] [Configuration] 31: metadata updated 09:39:24.115 CNTRLR [Node 031] [Configuration] 32: metadata updated 09:39:24.116 CNTRLR [Node 031] [Configuration] 33: metadata updated 09:39:24.117 CNTRLR [Node 031] [Configuration] 39: metadata updated 09:39:24.119 CNTRLR [Node 031] [Configuration] 40: metadata updated 09:39:24.120 CNTRLR [Node 031] [Configuration] 41: metadata updated 09:39:24.121 CNTRLR [Node 031] [Configuration] 42: metadata updated 09:39:24.122 CNTRLR [Node 031] [Configuration] 43: metadata updated 09:39:24.123 CNTRLR [Node 031] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:39:24.123 CNTRLR » [Node 031] querying parameter #1 value... 09:39:24.129 SERIAL « [ACK] (0x06) 09:39:24.130 SERIAL « 0x0104011301e8 (6 bytes) 09:39:24.130 SERIAL » [ACK] (0x06) 09:39:24.138 DRIVER « [RES] [SendData] was sent: true 09:39:24.164 SERIAL « 0x010700139800000271 (9 bytes) 09:39:24.164 SERIAL » [ACK] (0x06) 09:39:24.170 DRIVER « [REQ] [SendData] callback id: 152 transmit status: OK 09:39:24.178 SERIAL « 0x010b0004001a058e0301070064 (13 bytes) 09:39:24.179 SERIAL » [ACK] (0x06) 09:39:24.180 CNTRLR [Node 026] [~] [Multi Channel Association] maxNodes[1]: 7 => 7 09:39:24.182 CNTRLR [Node 026] [~] [Multi Channel Association] nodeIds[1]: => 09:39:24.183 CNTRLR [Node 026] [~] [Multi Channel Association] endpoints[1]: => 09:39:24.184 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 7 node ids: endpoints: 09:39:24.187 SERIAL » 0x010900131c027502259930 (11 bytes) 09:39:24.188 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 153 └─[ProtectionCCGet] 09:39:24.188 CNTRLR « [Node 026] received information for multi channel association group #1: maximum # of nodes: 7 currently assigned nodes: currently assigned endpoints: 09:39:24.188 CNTRLR » [Node 026] querying multi channel association group #2... 09:39:24.220 SERIAL « [ACK] (0x06) 09:39:24.224 SERIAL « 0x0104011301e8 (6 bytes) 09:39:24.225 SERIAL » [ACK] (0x06) 09:39:24.227 DRIVER « [RES] [SendData] was sent: true 09:39:24.354 SERIAL « 0x010c000400030631050422048763 (14 bytes) 09:39:24.354 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:39:24.355 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 228.4 => 115.9 [Endpoint 0] 09:39:24.355 SERIAL » [ACK] (0x06) 09:39:24.356 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 115.9 09:39:25.546 SERIAL « 0x0107001399000088fa (9 bytes) 09:39:25.547 SERIAL » [ACK] (0x06) 09:39:25.547 DRIVER « [REQ] [SendData] callback id: 153 transmit status: OK 09:39:25.659 SERIAL « 0x01090004001c037503009b (11 bytes) 09:39:25.661 CNTRLR [Node 028] [~] [Protection] local: 0 => 0 [Endpoint 0] 09:39:25.661 SERIAL » [ACK] (0x06) 09:39:25.662 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected 09:39:25.675 SERIAL » 0x010a00131a038e0202259ace (12 bytes) 09:39:25.676 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 154 └─[MultiChannelAssociationCCGet] group id: 2 09:39:25.677 CNTRLR « [Node 028] received protection status: local: Unprotected 09:39:25.677 CNTRLR [Node 028] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 09:39:25.740 SERIAL « [ACK] (0x06) 09:39:25.747 SERIAL « 0x0104011301e8 (6 bytes) 09:39:25.747 SERIAL » [ACK] (0x06) 09:39:25.748 DRIVER « [RES] [SendData] was sent: true 09:39:25.751 SERIAL « 0x010700139a00000776 (9 bytes) 09:39:25.751 SERIAL » [ACK] (0x06) 09:39:25.752 CNTRLR [Node 028] ClockCC: doing a partial interview... 09:39:25.752 CNTRLR » [Node 028] requesting current clock setting... 09:39:25.754 DRIVER « [REQ] [SendData] callback id: 154 transmit status: OK 09:39:25.759 SERIAL « 0x010b0004001a058e0302070067 (13 bytes) 09:39:25.759 SERIAL » [ACK] (0x06) 09:39:25.760 CNTRLR [Node 026] [~] [Multi Channel Association] maxNodes[2]: 7 => 7 09:39:25.761 CNTRLR [Node 026] [~] [Multi Channel Association] nodeIds[2]: => 09:39:25.762 CNTRLR [Node 026] [~] [Multi Channel Association] endpoints[2]: => 09:39:25.763 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 7 node ids: endpoints: 09:39:25.766 SERIAL » 0x010a0013180370051f259b29 (12 bytes) 09:39:25.766 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 155 └─[ConfigurationCCGet] parameter #: 31 09:39:25.767 CNTRLR « [Node 026] received information for multi channel association group #2: maximum # of nodes: 7 currently assigned nodes: currently assigned endpoints: 09:39:25.767 CNTRLR » [Node 026] querying additional non-multi-channel association groups... 09:39:25.767 CNTRLR » [Node 026] querying association group #3... 09:39:25.770 SERIAL « [ACK] (0x06) 09:39:25.775 SERIAL « 0x0104011301e8 (6 bytes) 09:39:25.775 SERIAL » [ACK] (0x06) 09:39:25.777 DRIVER « [RES] [SendData] was sent: true 09:39:25.795 SERIAL « 0x010700139b00000373 (9 bytes) 09:39:25.795 SERIAL » [ACK] (0x06) 09:39:25.796 DRIVER « [REQ] [SendData] callback id: 155 transmit status: OK 09:39:25.809 SERIAL « 0x010c000400180670061f0200ff7d (14 bytes) 09:39:25.815 CNTRLR [Node 024] [~] [Configuration] 31: 255 => 255 09:39:25.815 SERIAL » [ACK] (0x06) 09:39:25.816 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 2 value: 255 09:39:25.819 SERIAL » 0x010a00131a03850203259cc2 (12 bytes) 09:39:25.820 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 156 └─[AssociationCCGet] group id: 3 09:39:25.820 CNTRLR « [Node 024] parameter #31 has value: 255 09:39:25.820 CNTRLR » [Node 024] querying parameter #32 value... 09:39:25.823 SERIAL « [ACK] (0x06) 09:39:25.828 SERIAL « 0x0104011301e8 (6 bytes) 09:39:25.828 SERIAL » [ACK] (0x06) 09:39:25.829 DRIVER « [RES] [SendData] was sent: true 09:39:25.846 SERIAL « 0x010700139c00000275 (9 bytes) 09:39:25.846 SERIAL » [ACK] (0x06) 09:39:25.847 DRIVER « [REQ] [SendData] callback id: 156 transmit status: OK 09:39:25.857 SERIAL « 0x010c0004001a068503030100016e (14 bytes) 09:39:25.857 SERIAL » [ACK] (0x06) 09:39:25.859 CNTRLR [Node 026] [~] [Association] maxNodes[3]: 1 => 1 [internal] 09:39:25.859 CNTRLR [Node 026] [~] [Association] nodeIds[3]: 1 => 1 [internal] 09:39:25.860 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 09:39:25.865 SERIAL » 0x0109001306029840259d81 (11 bytes) 09:39:25.865 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 157 └─[SecurityCCNonceGet] 09:39:25.865 CNTRLR « [Node 026] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 09:39:25.866 CNTRLR [Node 026] [~] [Association] hasLifeline: true => true [internal] 09:39:25.866 CNTRLR [Node 026] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 09:39:25.866 CNTRLR [Node 026] Interview stage completed: CommandClasses 09:39:25.867 CNTRLR [Node 026] Interview stage completed: OverwriteConfig 09:39:25.867 CNTRLR » [Node 026] requesting node neighbors... 09:39:25.869 SERIAL « [ACK] (0x06) 09:39:25.873 SERIAL « 0x0104011301e8 (6 bytes) 09:39:25.873 SERIAL » [ACK] (0x06) 09:39:25.874 DRIVER « [RES] [SendData] was sent: true 09:39:26.528 CNTRLR [Node 029] Beginning interview - last completed stage: RestartFromCache 09:39:26.528 CNTRLR » [Node 029] pinging the node... 09:39:27.124 SERIAL « 0x010700139d00007e08 (9 bytes) 09:39:27.124 SERIAL » [ACK] (0x06) 09:39:27.125 DRIVER « [REQ] [SendData] callback id: 157 transmit status: OK 09:39:27.146 SERIAL « 0x0110000400060a9880dd1b8aa11782189e01 (18 bytes) 09:39:27.147 SERIAL » [ACK] (0x06) 09:39:27.148 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xdd1b8aa11782189e 09:39:27.154 SERIAL » 0x01210013061a98816ef5a09ec0e68726a960a930167443dd6aceb546ccd6cc622 (35 bytes) 59e1e 09:39:27.155 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 158 └─[SecurityCCCommandEncapsulation] │ nonce id: 221 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 09:39:27.159 SERIAL « [ACK] (0x06) 09:39:27.166 SERIAL « 0x0104011301e8 (6 bytes) 09:39:27.166 SERIAL » [ACK] (0x06) 09:39:27.167 DRIVER « [RES] [SendData] was sent: true 09:39:27.191 SERIAL « 0x010700139e00000376 (9 bytes) 09:39:27.191 SERIAL » [ACK] (0x06) 09:39:27.192 DRIVER « [REQ] [SendData] callback id: 158 transmit status: OK 09:39:27.309 SERIAL « 0x0108000400060298402f (10 bytes) 09:39:27.310 SERIAL » [ACK] (0x06) 09:39:27.311 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:39:27.319 SERIAL » 0x01110013060a9880a4a11b5a8602fd412400b1 (19 bytes) 09:39:27.319 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xa4a11b5a8602fd41 09:39:27.321 SERIAL « [ACK] (0x06) 09:39:27.328 SERIAL « 0x0104011301e8 (6 bytes) 09:39:27.329 SERIAL » [ACK] (0x06) 09:39:27.329 DRIVER « [RES] [SendData] was sent: true 09:39:27.370 SERIAL « 0x0121000400061b988156b2875dd7d374206e2f5f887e5e1994a44daac0f10b4a0 (35 bytes) 83585 09:39:27.371 SERIAL » [ACK] (0x06) 09:39:27.373 CNTRLR [Node 006] [~] [Protection] local: 0 => 0 [Endpoint 1] 09:39:27.374 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ProtectionCCReport] local: Unprotected 09:39:27.379 SERIAL » 0x010700801a00000062 (9 bytes) 09:39:27.380 DRIVER » [Node 026] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:39:27.381 CNTRLR « [Node 006] received protection status: local: Unprotected 09:39:27.382 CNTRLR [Node 006] [~] [Protection] interviewComplete: true => [Endpoint 1] [internal] true 09:39:27.432 SERIAL « [ACK] (0x06) 09:39:27.437 SERIAL « 0x012001806579ec7d0300000000000000000000000000000000000000000000000 (34 bytes) 0d0 09:39:27.437 SERIAL » [ACK] (0x06) 09:39:27.439 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 9, 12, 13, 14, 15, 19, 20, 22, 23, 24, 25, 27, 28, 29, 30, 31, 33, 34 09:39:27.445 SERIAL » 0x010800131d0100259f42 (10 bytes) 09:39:27.445 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 159 └─[NoOperationCC] 09:39:27.446 CNTRLR « [Node 026] node neighbors received: 1, 3, 6, 7, 9, 12, 13, 14, 15, 19, 20, 2 2, 23, 24, 25, 27, 28, 29, 30, 31, 33, 34 09:39:27.446 CNTRLR [Node 026] Interview stage completed: Neighbors 09:39:27.446 CNTRLR [Node 026] Interview completed 09:39:27.448 SERIAL « [ACK] (0x06) 09:39:27.450 CNTRLR [Node 006] BatteryCC: doing a partial interview... [Endpoint 1] 09:39:27.451 CNTRLR » [Node 006] querying battery status... [Endpoint 1] 09:39:27.454 SERIAL « 0x0104011301e8 (6 bytes) 09:39:27.455 SERIAL » [ACK] (0x06) 09:39:27.455 DRIVER « [RES] [SendData] was sent: true 09:39:28.914 SERIAL « 0x010700139f000093e7 (9 bytes) 09:39:28.914 SERIAL » [ACK] (0x06) 09:39:28.914 DRIVER « [REQ] [SendData] callback id: 159 transmit status: OK 09:39:28.921 SERIAL » 0x010a00131f0370050125a00b (12 bytes) 09:39:28.921 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 160 └─[ConfigurationCCGet] parameter #: 1 09:39:28.922 CNTRLR « [Node 029] ping successful 09:39:28.925 CNTRLR [Node 029] ManufacturerSpecificCC: doing a partial interview... 09:39:28.926 CNTRLR [Node 029] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:39:28.977 SERIAL « [ACK] (0x06) 09:39:28.978 SERIAL « 0x0104011301e8 (6 bytes) 09:39:28.979 SERIAL » [ACK] (0x06) 09:39:28.979 DRIVER « [RES] [SendData] was sent: true 09:39:28.982 SERIAL « 0x01070013a000000249 (9 bytes) 09:39:28.982 SERIAL » [ACK] (0x06) 09:39:28.983 DRIVER « [REQ] [SendData] callback id: 160 transmit status: OK 09:39:28.986 SERIAL « 0x010b0004001f0570060101ff63 (13 bytes) 09:39:28.996 CNTRLR [Node 031] [~] [Configuration] 1: 255 => 255 09:39:28.997 SERIAL » [ACK] (0x06) 09:39:28.998 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 255 09:39:29.003 SERIAL » 0x010900131c02810525a1fb (11 bytes) 09:39:29.004 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 161 └─[ClockCCGet] 09:39:29.004 CNTRLR « [Node 031] parameter #1 has value: 255 09:39:29.004 CNTRLR » [Node 031] querying parameter #3 value... 09:39:29.009 SERIAL « [ACK] (0x06) 09:39:29.012 SERIAL « 0x0104011301e8 (6 bytes) 09:39:29.012 SERIAL » [ACK] (0x06) 09:39:29.013 DRIVER « [RES] [SendData] was sent: true 09:39:29.025 CNTRLR [Node 029] VersionCC: doing a partial interview... 09:39:29.026 CNTRLR [Node 029] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:39:29.026 CNTRLR [Node 029] trying to load device config 09:39:29.029 CNTRLR [Node 029] device config loaded 09:39:29.030 CNTRLR [Node 029] ZWavePlusCC: doing a partial interview... 09:39:29.030 CNTRLR [Node 029] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:39:29.030 CNTRLR » [Node 029] querying device endpoint information... 09:39:30.349 SERIAL « 0x01070013a1000086cc (9 bytes) 09:39:30.349 SERIAL » [ACK] (0x06) 09:39:30.350 DRIVER « [REQ] [SendData] callback id: 161 transmit status: OK 09:39:30.462 SERIAL « 0x010a0004001c048106e921a6 (12 bytes) 09:39:30.463 SERIAL » [ACK] (0x06) 09:39:30.464 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ClockCCReport] clock setting: Sunday, 09:33 09:39:30.469 SERIAL » 0x010900131d02600725a21a (11 bytes) 09:39:30.469 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 162 └─[MultiChannelCCEndPointGet] 09:39:30.470 CNTRLR « [Node 028] received current clock setting: Sunday, 09:33 09:39:30.470 CNTRLR [Node 028] [~] [Clock] interviewComplete: true => true [Endpoint 0] [internal] 09:39:30.530 SERIAL « [ACK] (0x06) 09:39:30.535 SERIAL « 0x0104011301e8 (6 bytes) 09:39:30.535 SERIAL » [ACK] (0x06) 09:39:30.536 DRIVER « [RES] [SendData] was sent: true 09:39:30.540 CNTRLR [Node 028] AssociationCC: doing a partial interview... 09:39:30.541 CNTRLR [Node 028] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 09:39:30.541 CNTRLR [Node 028] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:39:30.542 CNTRLR [Node 028] MultiChannelAssociationCC: doing a partial interview... 09:39:30.542 CNTRLR » [Node 028] querying multi channel association group #1... 09:39:30.613 SERIAL « 0x01070013a200000e47 (9 bytes) 09:39:30.614 SERIAL » [ACK] (0x06) 09:39:30.614 DRIVER « [REQ] [SendData] callback id: 162 transmit status: OK 09:39:30.719 SERIAL « 0x010b0004001d05600800020082 (13 bytes) 09:39:30.720 CNTRLR [Node 029] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:39:30.720 CNTRLR [Node 029] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 09:39:30.721 CNTRLR [Node 029] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:39:30.721 CNTRLR [Node 029] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 09:39:30.721 SERIAL » [ACK] (0x06) 09:39:30.722 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:39:30.725 SERIAL » 0x010a00131c038e020125a3f2 (12 bytes) 09:39:30.725 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 163 └─[MultiChannelAssociationCCGet] group id: 1 09:39:30.726 CNTRLR « [Node 029] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:39:30.726 CNTRLR » [Node 029] querying all endpoints... 09:39:30.728 SERIAL « [ACK] (0x06) 09:39:30.733 SERIAL « 0x0104011301e8 (6 bytes) 09:39:30.733 SERIAL » [ACK] (0x06) 09:39:30.733 DRIVER « [RES] [SendData] was sent: true 09:39:30.828 SERIAL « 0x01070013a300000a42 (9 bytes) 09:39:30.828 SERIAL » [ACK] (0x06) 09:39:30.828 DRIVER « [REQ] [SendData] callback id: 163 transmit status: OK 09:39:30.910 SERIAL « 0x010e0004001c088e030101000001006d (16 bytes) 09:39:30.910 SERIAL » [ACK] (0x06) 09:39:30.911 CNTRLR [Node 028] [~] [Multi Channel Association] maxNodes[1]: 1 => 1 09:39:30.912 CNTRLR [Node 028] [~] [Multi Channel Association] nodeIds[1]: => 09:39:30.913 CNTRLR [Node 028] [~] [Multi Channel Association] endpoints[1]: [object Object] => [o bject Object] 09:39:30.913 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 1 node ids: endpoints: 1:0 09:39:30.916 SERIAL » 0x010b00131d04600bffff25a414 (13 bytes) 09:39:30.917 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 164 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:39:30.917 CNTRLR « [Node 028] received information for multi channel association group #1: maximum # of nodes: 1 currently assigned nodes: currently assigned endpoints: 1:0 09:39:30.917 CNTRLR [Node 028] [~] [Association] hasLifeline: true => true [internal] 09:39:30.918 CNTRLR [Node 028] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 09:39:30.950 SERIAL « [ACK] (0x06) 09:39:30.956 SERIAL « 0x0104011301e8 (6 bytes) 09:39:30.957 SERIAL » [ACK] (0x06) 09:39:30.961 DRIVER « [RES] [SendData] was sent: true 09:39:30.964 CNTRLR [Node 028] AssociationGroupInfoCC: doing a partial interview... 09:39:30.964 CNTRLR [Node 028] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 09:39:30.964 CNTRLR [Node 028] NotificationCC: doing a partial interview... 09:39:30.965 CNTRLR [Node 028] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 09:39:30.965 CNTRLR [Node 028] Interview stage completed: CommandClasses 09:39:30.965 CNTRLR [Node 028] Interview stage completed: OverwriteConfig 09:39:30.965 CNTRLR » [Node 028] requesting node neighbors... 09:39:32.464 SERIAL « 0x01070013a400009bd4 (9 bytes) 09:39:32.465 SERIAL » [ACK] (0x06) 09:39:32.466 DRIVER « [REQ] [SendData] callback id: 164 transmit status: OK 09:39:32.550 SERIAL « 0x010d0004001d07600c00ffff010283 (15 bytes) 09:39:32.552 SERIAL » [ACK] (0x06) 09:39:32.553 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 09:39:32.559 SERIAL » 0x010700801c00000064 (9 bytes) 09:39:32.560 DRIVER » [Node 028] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:39:32.561 CNTRLR « [Node 029] received endpoints: 1, 2 09:39:32.561 CNTRLR » [Node 029] querying capabilities for endpoint #1... 09:39:32.566 SERIAL « [ACK] (0x06) 09:39:32.568 SERIAL « 0x0120018065f988530700000000000000000000000000000000000000000000000 (34 bytes) 01e 09:39:32.568 SERIAL » [ACK] (0x06) 09:39:32.569 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 9, 12, 13, 14, 15, 16, 20, 24, 25, 26, 29, 31, 33, 34, 35 09:39:32.577 SERIAL » 0x010a00131d0360090125a510 (12 bytes) 09:39:32.578 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 165 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:39:32.578 CNTRLR « [Node 028] node neighbors received: 1, 3, 6, 7, 9, 12, 13, 14, 15, 16, 20, 2 4, 25, 26, 29, 31, 33, 34, 35 09:39:32.578 CNTRLR [Node 028] Interview stage completed: Neighbors 09:39:32.656 SERIAL « [ACK] (0x06) 09:39:32.658 SERIAL « 0x0104011301e8 (6 bytes) 09:39:32.658 SERIAL » [ACK] (0x06) 09:39:32.661 DRIVER « [RES] [SendData] was sent: true 09:39:32.665 CNTRLR [Node 028] Interview completed 09:39:32.705 SERIAL « 0x01070013a500000d43 (9 bytes) 09:39:32.705 SERIAL » [ACK] (0x06) 09:39:32.706 DRIVER « [REQ] [SendData] callback id: 165 transmit status: OK 09:39:32.799 SERIAL « 0x011a0004001d14600a0108065e8e404353989f596c7175808185229d (28 bytes) 09:39:32.800 CNTRLR [Node 029] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 1] [internal] 64,67,83,152,159,89,108,113,117,128,129,133,34 => 94,142,64,67,83,152,159,89,1 08,113,117,128,129,133,34 09:39:32.800 SERIAL » [ACK] (0x06) 09:39:32.801 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:39:32.805 SERIAL » 0x010a0013180370052025a62b (12 bytes) 09:39:32.805 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 166 └─[ConfigurationCCGet] parameter #: 32 09:39:32.806 CNTRLR « [Node 029] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:39:32.806 CNTRLR » [Node 029] querying capabilities for endpoint #2... 09:39:32.809 SERIAL « [ACK] (0x06) 09:39:32.814 SERIAL « 0x0104011301e8 (6 bytes) 09:39:32.814 SERIAL » [ACK] (0x06) 09:39:32.815 DRIVER « [RES] [SendData] was sent: true 09:39:32.892 SERIAL « 0x01070013a600000944 (9 bytes) 09:39:32.892 SERIAL » [ACK] (0x06) 09:39:32.893 DRIVER « [REQ] [SendData] callback id: 166 transmit status: OK 09:39:32.906 SERIAL « 0x010c0004001806700620020000bd (14 bytes) 09:39:32.911 CNTRLR [Node 024] [~] [Configuration] 32: 0 => 0 09:39:32.913 SERIAL » [ACK] (0x06) 09:39:32.914 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 2 value: 0 09:39:32.916 SERIAL » 0x010a00131d0360090225a711 (12 bytes) 09:39:32.917 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 167 └─[MultiChannelCCCapabilityGet] endpoint: 2 09:39:32.917 CNTRLR « [Node 024] parameter #32 has value: 0 09:39:32.917 CNTRLR » [Node 024] querying parameter #33 value... 09:39:32.921 SERIAL « [ACK] (0x06) 09:39:32.927 SERIAL « 0x0104011301e8 (6 bytes) 09:39:32.927 SERIAL » [ACK] (0x06) 09:39:32.928 DRIVER « [RES] [SendData] was sent: true 09:39:33.008 SERIAL « 0x01070013a700000945 (9 bytes) 09:39:33.008 SERIAL » [ACK] (0x06) 09:39:33.008 DRIVER « [REQ] [SendData] callback id: 167 transmit status: OK 09:39:33.097 SERIAL « 0x01160004001d10600a0221015e8e31989f596c718085222d (24 bytes) 09:39:33.098 CNTRLR [Node 029] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 2] [internal] 49,152,159,89,108,113,128,133,34 => 94,142,49,152,159,89,108,113,128,133,34 09:39:33.098 SERIAL » [ACK] (0x06) 09:39:33.099 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:39:33.103 SERIAL » 0x010900130602984025a8b4 (11 bytes) 09:39:33.104 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 168 └─[SecurityCCNonceGet] 09:39:33.104 CNTRLR « [Node 029] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:39:33.105 CNTRLR [Node 029] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:39:33.132 SERIAL « [ACK] (0x06) 09:39:33.135 SERIAL « 0x0104011301e8 (6 bytes) 09:39:33.135 SERIAL » [ACK] (0x06) 09:39:33.136 DRIVER « [RES] [SendData] was sent: true 09:39:33.139 CNTRLR [Node 029] BatteryCC: doing a partial interview... 09:39:33.139 CNTRLR » [Node 029] querying battery status... 09:39:33.194 SERIAL « 0x01090004001e03300300dc (11 bytes) 09:39:33.195 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:39:33.196 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:39:33.196 SERIAL » [ACK] (0x06) 09:39:33.197 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:39:33.278 SERIAL « 0x01090004001e03200100ce (11 bytes) 09:39:33.279 SERIAL » [ACK] (0x06) 09:39:33.280 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:39:33.281 CNTRLR [Node 030] treating BasicCC Set as a report 09:39:33.281 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:39:34.485 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 09:39:34.485 SERIAL » [ACK] (0x06) 09:39:34.486 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  09:39:34.488 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 09:39:34.491 SERIAL « 0x01070013a800008ac9 (9 bytes) 09:39:34.491 SERIAL » [ACK] (0x06) 09:39:34.492 DRIVER « [REQ] [SendData] callback id: 168 transmit status: OK 09:39:34.591 SERIAL « 0x0110000400060a988000e5dacf9a222d40da (18 bytes) 09:39:34.592 SERIAL » [ACK] (0x06) 09:39:34.592 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x00e5dacf9a222d40 09:39:34.597 SERIAL » 0x01210013061a988193918e10deec71cc9f2964b75c9f6600bb9b4c2f7acce68b2 (35 bytes) 5a90f 09:39:34.597 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 169 └─[SecurityCCCommandEncapsulation] │ nonce id: 0 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BatteryCCGet] 09:39:34.600 SERIAL « [ACK] (0x06) 09:39:34.607 SERIAL « 0x0104011301e8 (6 bytes) 09:39:34.608 SERIAL » [ACK] (0x06) 09:39:34.608 DRIVER « [RES] [SendData] was sent: true 09:39:34.633 SERIAL « 0x01070013a900000341 (9 bytes) 09:39:34.633 SERIAL » [ACK] (0x06) 09:39:34.634 DRIVER « [REQ] [SendData] callback id: 169 transmit status: OK 09:39:34.750 SERIAL « 0x0108000400060298402f (10 bytes) 09:39:34.751 SERIAL » [ACK] (0x06) 09:39:34.751 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:39:34.756 SERIAL » 0x01110013060a9880be901123d959196a240022 (19 bytes) 09:39:34.756 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xbe901123d959196a 09:39:34.760 SERIAL « [ACK] (0x06) 09:39:34.765 SERIAL « 0x0104011301e8 (6 bytes) 09:39:34.765 SERIAL » [ACK] (0x06) 09:39:34.766 DRIVER « [RES] [SendData] was sent: true 09:39:34.807 SERIAL « 0x0121000400061b98812c8b4a157b427f9a0e8dbb3157ab2d7abe96ae32b84c9e1 (35 bytes) c1389 09:39:34.808 SERIAL » [ACK] (0x06) 09:39:34.809 CNTRLR [Node 006] [~] [Battery] level: 89 => 89 [Endpoint 1] 09:39:34.810 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 1] 09:39:34.811 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BatteryCCReport] level: 89 is low: false 09:39:34.814 SERIAL » 0x010900131d02800225aaf7 (11 bytes) 09:39:34.814 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 170 └─[BatteryCCGet] 09:39:34.815 CNTRLR « [Node 006] received response for battery information: [Endpoint 1] level: 89 09:39:34.816 CNTRLR [Node 006] [~] [Battery] interviewComplete: true => tr [Endpoint 1] [internal] ue 09:39:34.846 SERIAL « [ACK] (0x06) 09:39:34.851 SERIAL « 0x0104011301e8 (6 bytes) 09:39:34.851 SERIAL » [ACK] (0x06) 09:39:34.853 DRIVER « [RES] [SendData] was sent: true 09:39:34.855 CNTRLR [Node 006] ClockCC: doing a partial interview... 09:39:34.855 CNTRLR » [Node 006] requesting current clock setting... 09:39:36.302 SERIAL « 0x01070013aa000094d5 (9 bytes) 09:39:36.302 SERIAL » [ACK] (0x06) 09:39:36.303 DRIVER « [REQ] [SendData] callback id: 170 transmit status: OK 09:39:36.414 SERIAL « 0x01090004001d038003630c (11 bytes) 09:39:36.415 CNTRLR [Node 029] [~] [Battery] level: 99 => 99 [Endpoint 0] 09:39:36.416 CNTRLR [Node 029] [~] [Battery] isLow: false => false [Endpoint 0] 09:39:36.417 SERIAL » [ACK] (0x06) 09:39:36.419 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 99 is low: false 09:39:36.426 SERIAL » 0x010a00131f0370050325ab02 (12 bytes) 09:39:36.427 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 171 └─[ConfigurationCCGet] parameter #: 3 09:39:36.428 CNTRLR « [Node 029] received response for battery information: level: 99 09:39:36.429 CNTRLR [Node 029] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:39:36.507 SERIAL « [ACK] (0x06) 09:39:36.515 SERIAL « 0x0104011301e8 (6 bytes) 09:39:36.515 SERIAL » [ACK] (0x06) 09:39:36.518 DRIVER « [RES] [SendData] was sent: true 09:39:36.519 SERIAL « 0x01070013ab00000848 (9 bytes) 09:39:36.520 SERIAL » [ACK] (0x06) 09:39:36.521 CNTRLR [Node 029] WakeUpCC: doing a partial interview... 09:39:36.521 CNTRLR [Node 029] skipping wakeup configuration for frequent listening device 09:39:36.521 CNTRLR [Node 029] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:39:36.524 CNTRLR [Node 029] ZWavePlusCC: doing a partial interview... [Endpoint 1] 09:39:36.524 CNTRLR [Node 029] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 09:39:36.524 CNTRLR [Node 029] ThermostatModeCC: doing a partial interview... [Endpoint 1] 09:39:36.524 CNTRLR » [Node 029] querying current thermostat mode... [Endpoint 1] 09:39:36.527 DRIVER « [REQ] [SendData] callback id: 171 transmit status: OK 09:39:36.529 SERIAL « 0x010b0004001f0570060301009e (13 bytes) 09:39:36.534 CNTRLR [Node 031] [~] [Configuration] 3: 0 => 0 09:39:36.535 SERIAL » [ACK] (0x06) 09:39:36.536 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 09:39:36.538 SERIAL » 0x010d00131d06600d0001400225ac5d (15 bytes) 09:39:36.539 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 172 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:39:36.539 CNTRLR « [Node 031] parameter #3 has value: 0 09:39:36.539 CNTRLR » [Node 031] querying parameter #4 value... 09:39:36.543 SERIAL « [ACK] (0x06) 09:39:36.548 SERIAL « 0x0104011301e8 (6 bytes) 09:39:36.548 SERIAL » [ACK] (0x06) 09:39:36.548 DRIVER « [RES] [SendData] was sent: true 09:39:36.631 SERIAL « 0x01070013ac0000084f (9 bytes) 09:39:36.631 SERIAL » [ACK] (0x06) 09:39:36.631 DRIVER « [REQ] [SendData] callback id: 172 transmit status: OK 09:39:36.710 SERIAL « 0x010d0004001d07600d0100400301c2 (15 bytes) 09:39:36.711 CNTRLR [Node 029] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 09:39:36.712 SERIAL » [ACK] (0x06) 09:39:36.713 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 09:39:36.716 SERIAL » 0x010a0013180370052125ad21 (12 bytes) 09:39:36.716 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 173 └─[ConfigurationCCGet] parameter #: 33 09:39:36.717 CNTRLR « [Node 029] received current thermostat mode: Heat [Endpoint 1] 09:39:36.717 CNTRLR [Node 029] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 1] [internal] ue => true 09:39:36.718 CNTRLR [Node 029] ThermostatSetpointCC: doing a partial interview... [Endpoint 1] 09:39:36.718 CNTRLR » [Node 029] querying current value of setpoint Heating... [Endpoint 1] 09:39:36.721 SERIAL « [ACK] (0x06) 09:39:36.725 SERIAL « 0x0104011301e8 (6 bytes) 09:39:36.725 SERIAL » [ACK] (0x06) 09:39:36.725 DRIVER « [RES] [SendData] was sent: true 09:39:36.802 SERIAL « 0x01070013ad0000094f (9 bytes) 09:39:36.802 SERIAL » [ACK] (0x06) 09:39:36.803 DRIVER « [REQ] [SendData] callback id: 173 transmit status: OK 09:39:36.816 SERIAL « 0x010c0004001806700621020063df (14 bytes) 09:39:36.821 CNTRLR [Node 024] [~] [Configuration] 33: 99 => 99 09:39:36.822 SERIAL » [ACK] (0x06) 09:39:36.823 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 2 value: 99 09:39:36.826 SERIAL » 0x010e00131d07600d000143020125ae5f (16 bytes) 09:39:36.826 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 174 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:39:36.827 CNTRLR « [Node 024] parameter #33 has value: 99 09:39:36.827 CNTRLR » [Node 024] querying parameter #35 value... 09:39:36.830 SERIAL « [ACK] (0x06) 09:39:36.835 SERIAL « 0x0104011301e8 (6 bytes) 09:39:36.835 SERIAL » [ACK] (0x06) 09:39:36.836 DRIVER « [RES] [SendData] was sent: true 09:39:36.918 SERIAL « 0x01070013ae0000094c (9 bytes) 09:39:36.919 SERIAL » [ACK] (0x06) 09:39:36.919 DRIVER « [REQ] [SendData] callback id: 174 transmit status: OK 09:39:37.003 SERIAL « 0x01100004001d0a600d01004303012200a053 (18 bytes) 09:39:37.004 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpoint[1]: 16 => 16 [Endpoint 1] 09:39:37.004 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 09:39:37.005 SERIAL » [ACK] (0x06) 09:39:37.006 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 16 °C 09:39:37.010 SERIAL » 0x010900130602984025afb3 (11 bytes) 09:39:37.011 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 175 └─[SecurityCCNonceGet] 09:39:37.011 CNTRLR « [Node 029] received current value of setpoint Heating: 16 °C [Endpoint 1] 09:39:37.012 CNTRLR [Node 029] [~] [Thermostat Setpoint] interviewComplete [Endpoint 1] [internal] : true => true 09:39:37.012 CNTRLR [Node 029] NotificationCC: doing a partial interview... [Endpoint 1] 09:39:37.013 CNTRLR » [Node 029] querying notification status for Power Management... [Endpoint 1] 09:39:37.016 SERIAL « [ACK] (0x06) 09:39:37.019 SERIAL « 0x0104011301e8 (6 bytes) 09:39:37.019 SERIAL » [ACK] (0x06) 09:39:37.020 DRIVER « [RES] [SendData] was sent: true 09:39:38.310 SERIAL « 0x01070013af000081c5 (9 bytes) 09:39:38.311 SERIAL » [ACK] (0x06) 09:39:38.312 DRIVER « [REQ] [SendData] callback id: 175 transmit status: OK 09:39:38.331 SERIAL « 0x0110000400060a98800f2e6fc3e8e8631706 (18 bytes) 09:39:38.332 SERIAL » [ACK] (0x06) 09:39:38.334 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x0f2e6fc3e8e86317 09:39:38.341 SERIAL » 0x01210013061a9881c61b56cc5416b4a9789606ecde821e0fe1c6f211d50e74902 (35 bytes) 5b0f7 09:39:38.342 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 176 └─[SecurityCCCommandEncapsulation] │ nonce id: 15 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ClockCCGet] 09:39:38.345 SERIAL « [ACK] (0x06) 09:39:38.352 SERIAL « 0x0104011301e8 (6 bytes) 09:39:38.353 SERIAL » [ACK] (0x06) 09:39:38.354 DRIVER « [RES] [SendData] was sent: true 09:39:38.378 SERIAL « 0x01070013b000000358 (9 bytes) 09:39:38.378 SERIAL » [ACK] (0x06) 09:39:38.379 DRIVER « [REQ] [SendData] callback id: 176 transmit status: OK 09:39:38.497 SERIAL « 0x0108000400060298402f (10 bytes) 09:39:38.497 SERIAL » [ACK] (0x06) 09:39:38.498 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:39:38.505 SERIAL » 0x01110013060a98800aaee82a99a7b54c24006c (19 bytes) 09:39:38.505 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x0aaee82a99a7b54c 09:39:38.507 SERIAL « [ACK] (0x06) 09:39:38.514 SERIAL « 0x0104011301e8 (6 bytes) 09:39:38.514 SERIAL » [ACK] (0x06) 09:39:38.515 DRIVER « [RES] [SendData] was sent: true 09:39:38.556 SERIAL « 0x0122000400061c98818b2c85236d10c7aa8df6c2c71c30a666d80a82ca14c86ee (36 bytes) d4cd303 09:39:38.557 SERIAL » [ACK] (0x06) 09:39:38.558 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ClockCCReport] clock setting: Sunday, 09:33 09:39:38.562 SERIAL » 0x011000131d09600d0001710400080025b16d (18 bytes) 09:39:38.563 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 177 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: Power Management 09:39:38.563 CNTRLR « [Node 006] received current clock setting: Sunday, 09:33 09:39:38.564 CNTRLR [Node 006] [~] [Clock] interviewComplete: true => true [Endpoint 1] [internal] 09:39:38.594 SERIAL « [ACK] (0x06) 09:39:38.595 SERIAL « 0x0104011301e8 (6 bytes) 09:39:38.595 SERIAL » [ACK] (0x06) 09:39:38.598 DRIVER « [RES] [SendData] was sent: true 09:39:38.602 CNTRLR [Node 006] ZWavePlusCC: doing a partial interview... [Endpoint 2] 09:39:38.603 CNTRLR [Node 006] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 09:39:38.603 CNTRLR [Node 006] MultilevelSensorCC: doing a partial interview... [Endpoint 2] 09:39:38.603 CNTRLR » [Node 006] querying Air temperature sensor reading... [Endpoint 2] 09:39:38.659 SERIAL « 0x01070013b100000953 (9 bytes) 09:39:38.659 SERIAL » [ACK] (0x06) 09:39:38.659 DRIVER « [REQ] [SendData] callback id: 177 transmit status: OK 09:39:38.745 SERIAL « 0x01130004001d0d600d01007105000000ff08fe00e9 (21 bytes) 09:39:38.746 SERIAL » [ACK] (0x06) 09:39:38.746 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 09:39:38.749 SERIAL » 0x010a00131f0370050425b21c (12 bytes) 09:39:38.750 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 178 └─[ConfigurationCCGet] parameter #: 4 09:39:38.750 CNTRLR [Node 029] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 1] 54 09:39:38.751 CNTRLR » [Node 029] querying notification status for System... [Endpoint 1] 09:39:38.780 SERIAL « [ACK] (0x06) 09:39:38.784 SERIAL « 0x0104011301e8 (6 bytes) 09:39:38.784 SERIAL » [ACK] (0x06) 09:39:38.785 DRIVER « [RES] [SendData] was sent: true 09:39:38.838 SERIAL « 0x01070013b200000851 (9 bytes) 09:39:38.839 SERIAL » [ACK] (0x06) 09:39:38.839 DRIVER « [REQ] [SendData] callback id: 178 transmit status: OK 09:39:38.849 SERIAL « 0x010c0004001f067006040200009e (14 bytes) 09:39:38.855 CNTRLR [Node 031] [~] [Configuration] 4: 0 => 0 09:39:38.856 SERIAL » [ACK] (0x06) 09:39:38.856 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 2 value: 0 09:39:38.859 SERIAL » 0x011000131d09600d0001710400090025b36e (18 bytes) 09:39:38.860 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 179 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: System 09:39:38.860 CNTRLR « [Node 031] parameter #4 has value: 0 09:39:38.860 CNTRLR » [Node 031] querying parameter #5 value... 09:39:38.864 SERIAL « [ACK] (0x06) 09:39:38.871 SERIAL « 0x0104011301e8 (6 bytes) 09:39:38.872 SERIAL » [ACK] (0x06) 09:39:38.882 DRIVER « [RES] [SendData] was sent: true 09:39:38.956 SERIAL « 0x01070013b300000951 (9 bytes) 09:39:38.957 SERIAL » [ACK] (0x06) 09:39:38.957 DRIVER « [REQ] [SendData] callback id: 179 transmit status: OK 09:39:39.045 SERIAL « 0x01130004001d0d600d01007105000000ff09fe00e8 (21 bytes) 09:39:39.046 SERIAL » [ACK] (0x06) 09:39:39.046 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: System notification status: 255 notification event: Unknown (0xfe) 09:39:39.049 SERIAL » 0x010a0013180370052325b43a (12 bytes) 09:39:39.049 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 180 └─[ConfigurationCCGet] parameter #: 35 09:39:39.050 CNTRLR [Node 029] [~] [Notification] System[unknown]: 254 => 254 [Endpoint 1] 09:39:39.051 CNTRLR [Node 029] [~] [Notification] interviewComplete: true [Endpoint 1] [internal] => true 09:39:39.084 SERIAL « [ACK] (0x06) 09:39:39.085 SERIAL « 0x0104011301e8 (6 bytes) 09:39:39.086 SERIAL » [ACK] (0x06) 09:39:39.087 DRIVER « [RES] [SendData] was sent: true 09:39:39.089 CNTRLR [Node 029] ProtectionCC: doing a partial interview... 09:39:39.089 CNTRLR » [Node 029] querying protection status... 09:39:39.142 SERIAL « 0x01070013b400000956 (9 bytes) 09:39:39.143 SERIAL » [ACK] (0x06) 09:39:39.144 DRIVER « [REQ] [SendData] callback id: 180 transmit status: OK 09:39:39.156 SERIAL « 0x010b00040018057006230100b9 (13 bytes) 09:39:39.166 CNTRLR [Node 024] [~] [Configuration] 35: 0 => 0 09:39:39.168 SERIAL » [ACK] (0x06) 09:39:39.169 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 0 09:39:39.174 SERIAL » 0x010d00131d06600d0001750225b571 (15 bytes) 09:39:39.175 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 181 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 09:39:39.175 CNTRLR « [Node 024] parameter #35 has value: 0 09:39:39.176 CNTRLR » [Node 024] querying parameter #36 value... 09:39:39.181 SERIAL « [ACK] (0x06) 09:39:39.184 SERIAL « 0x0104011301e8 (6 bytes) 09:39:39.184 SERIAL » [ACK] (0x06) 09:39:39.187 DRIVER « [RES] [SendData] was sent: true 09:39:39.267 SERIAL « 0x01070013b500000957 (9 bytes) 09:39:39.267 SERIAL » [ACK] (0x06) 09:39:39.268 DRIVER « [REQ] [SendData] callback id: 181 transmit status: OK 09:39:40.871 CNTRLR [Node 029] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:39:41.377 SERIAL » 0x010d00131d06600d0001750225b571 (15 bytes) 09:39:41.378 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 181 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 09:39:41.380 SERIAL « [ACK] (0x06) 09:39:41.386 SERIAL « 0x0104011301e8 (6 bytes) 09:39:41.387 SERIAL » [ACK] (0x06) 09:39:41.388 DRIVER « [RES] [SendData] was sent: true 09:39:41.470 SERIAL « 0x01070013b500000957 (9 bytes) 09:39:41.471 SERIAL » [ACK] (0x06) 09:39:41.472 DRIVER « [REQ] [SendData] callback id: 181 transmit status: OK 09:39:41.551 SERIAL « 0x010d0004001d07600d0100750300f6 (15 bytes) 09:39:41.553 CNTRLR [Node 029] [~] [Protection] local: 0 => 0 [Endpoint 1] 09:39:41.553 SERIAL » [ACK] (0x06) 09:39:41.555 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ProtectionCCReport] local: Unprotected 09:39:41.564 SERIAL » 0x010900130602984025b6aa (11 bytes) 09:39:41.564 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 182 └─[SecurityCCNonceGet] 09:39:41.565 CNTRLR « [Node 029] received protection status: local: Unprotected 09:39:41.566 CNTRLR [Node 029] [~] [Protection] interviewComplete: true => [Endpoint 1] [internal] true 09:39:41.619 SERIAL « [ACK] (0x06) 09:39:41.625 SERIAL « 0x0104011301e8 (6 bytes) 09:39:41.626 SERIAL » [ACK] (0x06) 09:39:41.626 DRIVER « [RES] [SendData] was sent: true 09:39:41.631 CNTRLR [Node 029] BatteryCC: doing a partial interview... [Endpoint 1] 09:39:41.631 CNTRLR » [Node 029] querying battery status... [Endpoint 1] 09:39:42.897 SERIAL « 0x01070013b6000085d8 (9 bytes) 09:39:42.897 SERIAL » [ACK] (0x06) 09:39:42.897 DRIVER « [REQ] [SendData] callback id: 182 transmit status: OK 09:39:42.919 SERIAL « 0x0110000400060a9880309c4a5f4c19292b11 (18 bytes) 09:39:42.919 SERIAL » [ACK] (0x06) 09:39:42.920 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x309c4a5f4c19292b 09:39:42.931 SERIAL » 0x01230013061c98811513338cd2acef3c7b0249c7c75b1d1e8b30b25b11e92b8b5 (37 bytes) 1a125b7d8 09:39:42.932 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 183 └─[SecurityCCCommandEncapsulation] │ nonce id: 48 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:39:42.935 SERIAL « [ACK] (0x06) 09:39:42.943 SERIAL « 0x0104011301e8 (6 bytes) 09:39:42.943 SERIAL » [ACK] (0x06) 09:39:42.944 DRIVER « [RES] [SendData] was sent: true 09:39:42.968 SERIAL « 0x01070013b70000035f (9 bytes) 09:39:42.969 SERIAL » [ACK] (0x06) 09:39:42.969 DRIVER « [REQ] [SendData] callback id: 183 transmit status: OK 09:39:43.090 SERIAL « 0x0108000400060298402f (10 bytes) 09:39:43.091 SERIAL » [ACK] (0x06) 09:39:43.091 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:39:43.099 SERIAL » 0x01110013060a98803a84700dfcab03cf240095 (19 bytes) 09:39:43.099 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x3a84700dfcab03cf 09:39:43.101 SERIAL « [ACK] (0x06) 09:39:43.108 SERIAL « 0x0104011301e8 (6 bytes) 09:39:43.108 SERIAL » [ACK] (0x06) 09:39:43.109 DRIVER « [RES] [SendData] was sent: true 09:39:43.151 SERIAL « 0x0124000400061e9881a1a6fe95799fb61c51514a1269d52652c802c03a575b11c (38 bytes) 35d1c34d421 09:39:43.152 SERIAL » [ACK] (0x06) 09:39:43.154 CNTRLR [Node 006] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:39:43.155 CNTRLR [Node 006] [~] [Multilevel Sensor] Air temperature: 21.5 => 21.7 [Endpoint 2] 09:39:43.156 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 21.7 09:39:43.161 SERIAL » 0x010d00131d06600d0001800225b889 (15 bytes) 09:39:43.162 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 184 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BatteryCCGet] 09:39:43.163 CNTRLR « [Node 006] received current Air temperature sensor reading: 21.7 [Endpoint 2] °C 09:39:43.164 CNTRLR [Node 006] [~] [Multilevel Sensor] interviewComplete: [Endpoint 2] [internal] true => true 09:39:43.212 SERIAL « [ACK] (0x06) 09:39:43.214 SERIAL « 0x0104011301e8 (6 bytes) 09:39:43.215 SERIAL » [ACK] (0x06) 09:39:43.216 DRIVER « [RES] [SendData] was sent: true 09:39:43.218 CNTRLR [Node 006] NotificationCC: doing a partial interview... [Endpoint 2] 09:39:43.219 CNTRLR » [Node 006] querying notification status for Power Management... [Endpoint 2] 09:39:44.674 SERIAL « 0x01070013b8000097c4 (9 bytes) 09:39:44.675 SERIAL » [ACK] (0x06) 09:39:44.676 DRIVER « [REQ] [SendData] callback id: 184 transmit status: OK 09:39:44.790 SERIAL « 0x010d0004001d07600d010080036360 (15 bytes) 09:39:44.792 CNTRLR [Node 029] [~] [Battery] level: 99 => 99 [Endpoint 1] 09:39:44.793 CNTRLR [Node 029] [~] [Battery] isLow: false => false [Endpoint 1] 09:39:44.794 SERIAL » [ACK] (0x06) 09:39:44.796 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BatteryCCReport] level: 99 is low: false 09:39:44.802 SERIAL » 0x010a00131f0370050525b916 (12 bytes) 09:39:44.803 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 185 └─[ConfigurationCCGet] parameter #: 5 09:39:44.804 CNTRLR « [Node 029] received response for battery information: [Endpoint 1] level: 99 09:39:44.805 CNTRLR [Node 029] [~] [Battery] interviewComplete: true => tr [Endpoint 1] [internal] ue 09:39:44.872 SERIAL « [ACK] (0x06) 09:39:44.883 SERIAL « 0x0104011301e8 (6 bytes) 09:39:44.884 SERIAL » [ACK] (0x06) 09:39:44.886 DRIVER « [RES] [SendData] was sent: true 09:39:44.887 CNTRLR [Node 029] ClockCC: doing a partial interview... 09:39:44.887 CNTRLR » [Node 029] requesting current clock setting... 09:39:44.890 SERIAL « 0x01070013b90000085a (9 bytes) 09:39:44.890 SERIAL » [ACK] (0x06) 09:39:44.890 DRIVER « [REQ] [SendData] callback id: 185 transmit status: OK 09:39:44.899 SERIAL « 0x010c0004001f067006050200009f (14 bytes) 09:39:44.904 CNTRLR [Node 031] [~] [Configuration] 5: 0 => 0 09:39:44.905 SERIAL » [ACK] (0x06) 09:39:44.906 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 2 value: 0 09:39:44.909 SERIAL » 0x010d00131d06600d0001810525ba8d (15 bytes) 09:39:44.909 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 186 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ClockCCGet] 09:39:44.910 CNTRLR « [Node 031] parameter #5 has value: 0 09:39:44.910 CNTRLR » [Node 031] querying parameter #6 value... 09:39:44.913 SERIAL « [ACK] (0x06) 09:39:44.918 SERIAL « 0x0104011301e8 (6 bytes) 09:39:44.919 SERIAL » [ACK] (0x06) 09:39:44.919 DRIVER « [RES] [SendData] was sent: true 09:39:45.001 SERIAL « 0x01070013ba00000859 (9 bytes) 09:39:45.001 SERIAL » [ACK] (0x06) 09:39:45.002 DRIVER « [REQ] [SendData] callback id: 186 transmit status: OK 09:39:45.082 SERIAL « 0x010e0004001d08600d01008106e927c5 (16 bytes) 09:39:45.083 SERIAL » [ACK] (0x06) 09:39:45.084 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ClockCCReport] clock setting: Sunday, 09:39 09:39:45.086 SERIAL » 0x010a0013180370052425bb32 (12 bytes) 09:39:45.087 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 187 └─[ConfigurationCCGet] parameter #: 36 09:39:45.087 CNTRLR « [Node 029] received current clock setting: Sunday, 09:39 09:39:45.088 CNTRLR [Node 029] [~] [Clock] interviewComplete: true => true [Endpoint 1] [internal] 09:39:45.116 SERIAL « [ACK] (0x06) 09:39:45.117 SERIAL « 0x0104011301e8 (6 bytes) 09:39:45.117 SERIAL » [ACK] (0x06) 09:39:45.118 DRIVER « [RES] [SendData] was sent: true 09:39:45.121 CNTRLR [Node 029] ZWavePlusCC: doing a partial interview... [Endpoint 2] 09:39:45.121 CNTRLR [Node 029] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 09:39:45.121 CNTRLR [Node 029] MultilevelSensorCC: doing a partial interview... [Endpoint 2] 09:39:45.122 CNTRLR » [Node 029] querying Air temperature sensor reading... [Endpoint 2] 09:39:45.172 SERIAL « 0x01070013bb00000959 (9 bytes) 09:39:45.172 SERIAL » [ACK] (0x06) 09:39:45.172 DRIVER « [REQ] [SendData] callback id: 187 transmit status: OK 09:39:45.186 SERIAL « 0x010c00040018067006240200ff46 (14 bytes) 09:39:45.191 CNTRLR [Node 024] [~] [Configuration] 36: 255 => 255 09:39:45.192 SERIAL » [ACK] (0x06) 09:39:45.193 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 36 value size: 2 value: 255 09:39:45.195 SERIAL » 0x010f00131d08600d00023104010025bc34 (17 bytes) 09:39:45.196 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 188 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:39:45.196 CNTRLR « [Node 024] parameter #36 has value: 255 09:39:45.196 CNTRLR » [Node 024] querying parameter #37 value... 09:39:45.199 SERIAL « [ACK] (0x06) 09:39:45.211 SERIAL « 0x0104011301e8 (6 bytes) 09:39:45.211 SERIAL » [ACK] (0x06) 09:39:45.212 DRIVER « [RES] [SendData] was sent: true 09:39:45.298 SERIAL « 0x01070013bc0000095e (9 bytes) 09:39:45.298 SERIAL » [ACK] (0x06) 09:39:45.301 DRIVER « [REQ] [SendData] callback id: 188 transmit status: OK 09:39:45.374 SERIAL « 0x01100004001d0a600d02003105012200c246 (18 bytes) 09:39:45.375 CNTRLR [Node 029] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:39:45.376 CNTRLR [Node 029] [~] [Multilevel Sensor] Air temperature: 19.4 => 19.4 [Endpoint 2] 09:39:45.376 SERIAL » [ACK] (0x06) 09:39:45.377 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 19.4 09:39:45.381 SERIAL » 0x010900130602984025bda1 (11 bytes) 09:39:45.382 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 189 └─[SecurityCCNonceGet] 09:39:45.382 CNTRLR « [Node 029] received current Air temperature sensor reading: 19.4 [Endpoint 2] °C 09:39:45.383 CNTRLR [Node 029] [~] [Multilevel Sensor] interviewComplete: [Endpoint 2] [internal] true => true 09:39:45.383 CNTRLR [Node 029] NotificationCC: doing a partial interview... [Endpoint 2] 09:39:45.383 CNTRLR » [Node 029] querying notification status for Power Management... [Endpoint 2] 09:39:45.386 SERIAL « [ACK] (0x06) 09:39:45.390 SERIAL « 0x0104011301e8 (6 bytes) 09:39:45.390 SERIAL » [ACK] (0x06) 09:39:45.390 DRIVER « [RES] [SendData] was sent: true 09:39:46.687 SERIAL « 0x01070013bd000082d4 (9 bytes) 09:39:46.687 SERIAL » [ACK] (0x06) 09:39:46.688 DRIVER « [REQ] [SendData] callback id: 189 transmit status: OK 09:39:46.709 SERIAL « 0x0110000400060a9880e809ae2809eaf73cb0 (18 bytes) 09:39:46.710 SERIAL » [ACK] (0x06) 09:39:46.712 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xe809ae2809eaf73c 09:39:46.719 SERIAL » 0x01240013061d9881061ae416a1075de7c90fe231da91ef49868be8aad5bfd6177 (38 bytes) d862925be6d 09:39:46.721 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 190 └─[SecurityCCCommandEncapsulation] │ nonce id: 232 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: Power Management 09:39:46.725 SERIAL « [ACK] (0x06) 09:39:46.732 SERIAL « 0x0104011301e8 (6 bytes) 09:39:46.732 SERIAL » [ACK] (0x06) 09:39:46.734 DRIVER « [RES] [SendData] was sent: true 09:39:46.758 SERIAL « 0x01070013be00000356 (9 bytes) 09:39:46.758 SERIAL » [ACK] (0x06) 09:39:46.759 DRIVER « [REQ] [SendData] callback id: 190 transmit status: OK 09:39:46.786 SERIAL « 0x0108000400060298402f (10 bytes) 09:39:46.786 SERIAL » [ACK] (0x06) 09:39:46.787 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:39:46.795 SERIAL » 0x01110013060a9880e6ea22409cfa0df424003c (19 bytes) 09:39:46.796 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0xe6ea22409cfa0df4 09:39:46.798 SERIAL « [ACK] (0x06) 09:39:46.805 SERIAL « 0x0104011301e8 (6 bytes) 09:39:46.805 SERIAL » [ACK] (0x06) 09:39:46.806 DRIVER « [RES] [SendData] was sent: true 09:39:46.849 SERIAL « 0x01270004000621988156d37803afd7b2ddd1ecf82dbecee011dfd3c147e994e68 (41 bytes) 212727288b96c318f 09:39:46.850 SERIAL » [ACK] (0x06) 09:39:46.851 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 09:39:46.856 SERIAL » 0x011000131d09600d0002710400080025bf60 (18 bytes) 09:39:46.856 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 191 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: Power Management 09:39:46.857 CNTRLR [Node 006] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 2] 54 09:39:46.872 CNTRLR » [Node 006] querying notification status for System... [Endpoint 2] 09:39:46.878 SERIAL « [ACK] (0x06) 09:39:46.879 SERIAL « 0x0104011301e8 (6 bytes) 09:39:46.880 SERIAL » [ACK] (0x06) 09:39:46.881 DRIVER « [RES] [SendData] was sent: true 09:39:46.955 SERIAL « 0x01070013bf0000095d (9 bytes) 09:39:46.956 SERIAL » [ACK] (0x06) 09:39:46.956 DRIVER « [REQ] [SendData] callback id: 191 transmit status: OK 09:39:47.047 SERIAL « 0x01130004001d0d600d02007105000000ff08fe00ea (21 bytes) 09:39:47.048 SERIAL » [ACK] (0x06) 09:39:47.048 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 09:39:47.051 SERIAL » 0x010a00131f0370050625c06c (12 bytes) 09:39:47.051 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 192 └─[ConfigurationCCGet] parameter #: 6 09:39:47.052 CNTRLR [Node 029] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 2] 54 09:39:47.053 CNTRLR » [Node 029] querying notification status for System... [Endpoint 2] 09:39:47.057 SERIAL « [ACK] (0x06) 09:39:47.060 SERIAL « 0x0104011301e8 (6 bytes) 09:39:47.060 SERIAL » [ACK] (0x06) 09:39:47.061 DRIVER « [RES] [SendData] was sent: true 09:39:47.138 SERIAL « 0x01070013c000000823 (9 bytes) 09:39:47.139 SERIAL » [ACK] (0x06) 09:39:47.139 DRIVER « [REQ] [SendData] callback id: 192 transmit status: OK 09:39:47.149 SERIAL « 0x010b0004001f0570060601009b (13 bytes) 09:39:47.154 CNTRLR [Node 031] [~] [Configuration] 6: 0 => 0 09:39:47.155 SERIAL » [ACK] (0x06) 09:39:47.156 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 1 value: 0 09:39:47.159 SERIAL » 0x011000131d09600d0002710400090025c11f (18 bytes) 09:39:47.159 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 193 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:39:47.159 CNTRLR « [Node 031] parameter #6 has value: 0 09:39:47.160 CNTRLR » [Node 031] querying parameter #7 value... 09:39:47.163 SERIAL « [ACK] (0x06) 09:39:47.169 SERIAL « 0x0104011301e8 (6 bytes) 09:39:47.169 SERIAL » [ACK] (0x06) 09:39:47.169 DRIVER « [RES] [SendData] was sent: true 09:39:47.253 SERIAL « 0x01070013c100000923 (9 bytes) 09:39:47.253 SERIAL » [ACK] (0x06) 09:39:47.253 DRIVER « [REQ] [SendData] callback id: 193 transmit status: OK 09:39:47.580 SERIAL « 0x01080004101502840777 (10 bytes) 09:39:47.581 SERIAL » [ACK] (0x06) 09:39:47.581 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:39:47.582 CNTRLR « [Node 021] received wakeup notification 09:39:47.582 CNTRLR [Node 021] The node is now awake. 09:39:47.591 SERIAL « 0x01080004101502840777 (10 bytes) 09:39:47.591 SERIAL » [ACK] (0x06) 09:39:47.592 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:39:47.593 CNTRLR « [Node 021] received wakeup notification 09:39:47.665 SERIAL « 0x01080004101502840777 (10 bytes) 09:39:47.666 SERIAL » [ACK] (0x06) 09:39:47.666 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:39:47.668 CNTRLR « [Node 021] received wakeup notification 09:39:47.704 SERIAL « 0x01080004101502840777 (10 bytes) 09:39:47.705 SERIAL » [ACK] (0x06) 09:39:47.706 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:39:47.707 CNTRLR « [Node 021] received wakeup notification 09:39:47.715 SERIAL « 0x01080004101502840777 (10 bytes) 09:39:47.715 SERIAL » [ACK] (0x06) 09:39:47.716 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:39:47.718 CNTRLR « [Node 021] received wakeup notification 09:39:47.802 SERIAL « 0x01080004101502840777 (10 bytes) 09:39:47.803 SERIAL » [ACK] (0x06) 09:39:47.804 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:39:47.805 CNTRLR « [Node 021] received wakeup notification 09:39:47.813 SERIAL « 0x01080004101502840777 (10 bytes) 09:39:47.814 SERIAL » [ACK] (0x06) 09:39:47.815 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:39:47.816 CNTRLR « [Node 021] received wakeup notification 09:39:47.823 SERIAL « 0x01080004101502840777 (10 bytes) 09:39:47.823 SERIAL » [ACK] (0x06) 09:39:47.824 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:39:47.825 CNTRLR « [Node 021] received wakeup notification 09:39:47.872 SERIAL « 0x01080004101502840777 (10 bytes) 09:39:47.872 SERIAL » [ACK] (0x06) 09:39:47.873 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:39:47.875 CNTRLR « [Node 021] received wakeup notification 09:39:48.074 SERIAL « 0x01080004101502840777 (10 bytes) 09:39:48.074 SERIAL » [ACK] (0x06) 09:39:48.076 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:39:48.077 CNTRLR « [Node 021] received wakeup notification 09:39:48.117 SERIAL « 0x01080004101502840777 (10 bytes) 09:39:48.117 SERIAL » [ACK] (0x06) 09:39:48.118 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:39:48.119 CNTRLR « [Node 021] received wakeup notification 09:39:48.856 CNTRLR [Node 029] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:39:49.359 SERIAL » 0x011000131d09600d0002710400090025c11f (18 bytes) 09:39:49.362 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 193 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:39:49.373 SERIAL « [ACK] (0x06) 09:39:49.374 SERIAL « 0x0104011301e8 (6 bytes) 09:39:49.375 SERIAL » [ACK] (0x06) 09:39:49.375 DRIVER « [RES] [SendData] was sent: true 09:39:50.827 SERIAL « 0x01070013c1000092b8 (9 bytes) 09:39:50.828 SERIAL » [ACK] (0x06) 09:39:50.828 DRIVER « [REQ] [SendData] callback id: 193 transmit status: OK 09:39:52.430 CNTRLR [Node 029] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:39:52.933 SERIAL » 0x011000131d09600d0002710400090025c11f (18 bytes) 09:39:52.933 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 193 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:39:52.935 SERIAL « [ACK] (0x06) 09:39:52.942 SERIAL « 0x0104011301e8 (6 bytes) 09:39:52.942 SERIAL » [ACK] (0x06) 09:39:52.943 DRIVER « [RES] [SendData] was sent: true 09:39:54.432 SERIAL « 0x01070013c1000095bf (9 bytes) 09:39:54.432 SERIAL » [ACK] (0x06) 09:39:54.433 DRIVER « [REQ] [SendData] callback id: 193 transmit status: OK 09:39:56.044 SERIAL » 0x010a0013180370052525c24a (12 bytes) 09:39:56.045 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 194 └─[ConfigurationCCGet] parameter #: 37 09:39:56.046 CNTRLR [Node 029] Failed all interview attempts, giving up. 09:39:56.047 SERIAL « [ACK] (0x06) 09:39:56.053 SERIAL « 0x0104011301e8 (6 bytes) 09:39:56.054 SERIAL » [ACK] (0x06) 09:39:56.056 DRIVER « [RES] [SendData] was sent: true 09:39:56.075 SERIAL « 0x01070013c20000032a (9 bytes) 09:39:56.075 SERIAL » [ACK] (0x06) 09:39:56.076 DRIVER « [REQ] [SendData] callback id: 194 transmit status: OK 09:39:56.088 SERIAL « 0x010c0004001806700625020000b8 (14 bytes) 09:39:56.101 CNTRLR [Node 024] [~] [Configuration] 37: 0 => 0 09:39:56.103 SERIAL » [ACK] (0x06) 09:39:56.104 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 37 value size: 2 value: 0 09:39:56.114 SERIAL » 0x010900130602984025c3df (11 bytes) 09:39:56.114 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 195 └─[SecurityCCNonceGet] 09:39:56.115 CNTRLR « [Node 024] parameter #37 has value: 0 09:39:56.116 CNTRLR » [Node 024] querying parameter #38 value... 09:39:56.122 SERIAL « [ACK] (0x06) 09:39:56.125 SERIAL « 0x0104011301e8 (6 bytes) 09:39:56.125 SERIAL » [ACK] (0x06) 09:39:56.127 DRIVER « [RES] [SendData] was sent: true 09:39:57.434 SERIAL « 0x01070013c3000084ac (9 bytes) 09:39:57.434 SERIAL » [ACK] (0x06) 09:39:57.435 DRIVER « [REQ] [SendData] callback id: 195 transmit status: OK 09:39:57.456 SERIAL « 0x0110000400060a98804f3212740cd1205841 (18 bytes) 09:39:57.457 SERIAL » [ACK] (0x06) 09:39:57.458 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x4f3212740cd12058 09:39:57.464 SERIAL » 0x01240013061d988140598d9adaab02daf4103bec910e2a379d9b4f2539ce3c1a4 (38 bytes) e0e6b25c4ab 09:39:57.465 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 196 └─[SecurityCCCommandEncapsulation] │ nonce id: 79 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:39:57.469 SERIAL « [ACK] (0x06) 09:39:57.476 SERIAL « 0x0104011301e8 (6 bytes) 09:39:57.476 SERIAL » [ACK] (0x06) 09:39:57.477 DRIVER « [RES] [SendData] was sent: true 09:39:57.502 SERIAL « 0x01070013c40000032c (9 bytes) 09:39:57.502 SERIAL » [ACK] (0x06) 09:39:57.503 DRIVER « [REQ] [SendData] callback id: 196 transmit status: OK 09:39:57.583 DRIVER The awake timeout for node 21 has elapsed. Assuming it is asleep. 09:39:57.583 CNTRLR [Node 021] The node is now asleep. 09:39:59.106 CNTRLR [Node 006] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:39:59.615 SERIAL » 0x010900130602984025c5d9 (11 bytes) 09:39:59.616 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 197 └─[SecurityCCNonceGet] 09:39:59.618 SERIAL « [ACK] (0x06) 09:39:59.624 SERIAL « 0x0104011301e8 (6 bytes) 09:39:59.624 SERIAL » [ACK] (0x06) 09:39:59.625 DRIVER « [RES] [SendData] was sent: true 09:40:00.890 SERIAL « 0x01070013c500007f51 (9 bytes) 09:40:00.890 SERIAL » [ACK] (0x06) 09:40:00.891 DRIVER « [REQ] [SendData] callback id: 197 transmit status: OK 09:40:00.912 SERIAL « 0x0110000400060a988034aca7191bb118563d (18 bytes) 09:40:00.913 SERIAL » [ACK] (0x06) 09:40:00.914 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x34aca7191bb11856 09:40:00.920 SERIAL » 0x01240013061d9881facb92e6eeb4b7869fb11c86f9f1202ed8b5348f11df99df0 (38 bytes) 7910c25c473 09:40:00.921 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 196 └─[SecurityCCCommandEncapsulation] │ nonce id: 52 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:40:00.925 SERIAL « [ACK] (0x06) 09:40:00.932 SERIAL « 0x0104011301e8 (6 bytes) 09:40:00.932 SERIAL » [ACK] (0x06) 09:40:00.933 DRIVER « [RES] [SendData] was sent: true 09:40:00.964 SERIAL « 0x01070013c40000042b (9 bytes) 09:40:00.964 SERIAL » [ACK] (0x06) 09:40:00.965 DRIVER « [REQ] [SendData] callback id: 196 transmit status: OK 09:40:02.568 CNTRLR [Node 006] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:40:03.077 SERIAL » 0x010900130602984025c6da (11 bytes) 09:40:03.078 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 198 └─[SecurityCCNonceGet] 09:40:03.080 SERIAL « [ACK] (0x06) 09:40:03.086 SERIAL « 0x0104011301e8 (6 bytes) 09:40:03.087 SERIAL » [ACK] (0x06) 09:40:03.088 DRIVER « [RES] [SendData] was sent: true 09:40:04.352 SERIAL « 0x01070013c6000080ad (9 bytes) 09:40:04.353 SERIAL » [ACK] (0x06) 09:40:04.354 DRIVER « [REQ] [SendData] callback id: 198 transmit status: OK 09:40:04.374 SERIAL « 0x0110000400060a98800018ef3506fc24ee0d (18 bytes) 09:40:04.387 SERIAL » [ACK] (0x06) 09:40:04.388 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x0018ef3506fc24ee 09:40:04.395 SERIAL » 0x01240013061d9881bdae504ed9cc949bd53b8d20b73a2a9fb4600071b34fd5116 (38 bytes) 27f2925c4ee 09:40:04.395 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 196 └─[SecurityCCCommandEncapsulation] │ nonce id: 0 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 09:40:04.399 SERIAL « [ACK] (0x06) 09:40:04.406 SERIAL « 0x0104011301e8 (6 bytes) 09:40:04.407 SERIAL » [ACK] (0x06) 09:40:04.408 DRIVER « [RES] [SendData] was sent: true 09:40:04.433 SERIAL « 0x01070013c40000042b (9 bytes) 09:40:04.433 SERIAL » [ACK] (0x06) 09:40:04.434 DRIVER « [REQ] [SendData] callback id: 196 transmit status: OK 09:40:06.043 SERIAL » 0x010a00131f0370050725c76a (12 bytes) 09:40:06.044 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 199 └─[ConfigurationCCGet] parameter #: 7 09:40:06.044 CNTRLR [Node 006] Failed all interview attempts, giving up. 09:40:06.046 SERIAL « [ACK] (0x06) 09:40:06.052 SERIAL « 0x0104011301e8 (6 bytes) 09:40:06.053 SERIAL » [ACK] (0x06) 09:40:06.054 DRIVER « [RES] [SendData] was sent: true 09:40:06.069 SERIAL « 0x01070013c70000022e (9 bytes) 09:40:06.070 SERIAL » [ACK] (0x06) 09:40:06.071 DRIVER « [REQ] [SendData] callback id: 199 transmit status: OK 09:40:06.080 SERIAL « 0x010b0004001f0570060701009a (13 bytes) 09:40:06.093 CNTRLR [Node 031] [~] [Configuration] 7: 0 => 0 09:40:06.094 SERIAL » [ACK] (0x06) 09:40:06.096 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 7 value size: 1 value: 0 09:40:06.102 SERIAL » 0x010a0013180370052625c843 (12 bytes) 09:40:06.103 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 200 └─[ConfigurationCCGet] parameter #: 38 09:40:06.103 CNTRLR « [Node 031] parameter #7 has value: 0 09:40:06.104 CNTRLR » [Node 031] querying parameter #13 value... 09:40:06.110 SERIAL « [ACK] (0x06) 09:40:06.113 SERIAL « 0x0104011301e8 (6 bytes) 09:40:06.114 SERIAL » [ACK] (0x06) 09:40:06.117 DRIVER « [RES] [SendData] was sent: true 09:40:06.132 SERIAL « 0x01070013c800000320 (9 bytes) 09:40:06.133 SERIAL » [ACK] (0x06) 09:40:06.134 DRIVER « [REQ] [SendData] callback id: 200 transmit status: OK 09:40:06.146 SERIAL « 0x010c0004001806700626020063d8 (14 bytes) 09:40:06.151 CNTRLR [Node 024] [~] [Configuration] 38: 99 => 99 09:40:06.152 SERIAL » [ACK] (0x06) 09:40:06.153 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 38 value size: 2 value: 99 09:40:06.156 SERIAL » 0x010a00131f0370050d25c96e (12 bytes) 09:40:06.156 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 201 └─[ConfigurationCCGet] parameter #: 13 09:40:06.156 CNTRLR « [Node 024] parameter #38 has value: 99 09:40:06.157 CNTRLR » [Node 024] querying parameter #40 value... 09:40:06.160 SERIAL « [ACK] (0x06) 09:40:06.165 SERIAL « 0x0104011301e8 (6 bytes) 09:40:06.166 SERIAL » [ACK] (0x06) 09:40:06.166 DRIVER « [RES] [SendData] was sent: true 09:40:06.181 SERIAL « 0x01070013c900000220 (9 bytes) 09:40:06.181 SERIAL » [ACK] (0x06) 09:40:06.182 DRIVER « [REQ] [SendData] callback id: 201 transmit status: OK 09:40:06.192 SERIAL « 0x010b0004001f0570060d010090 (13 bytes) 09:40:06.197 CNTRLR [Node 031] [~] [Configuration] 13: 0 => 0 09:40:06.198 SERIAL » [ACK] (0x06) 09:40:06.199 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 0 09:40:06.201 SERIAL » 0x010a0013180370052825ca4f (12 bytes) 09:40:06.202 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 202 └─[ConfigurationCCGet] parameter #: 40 09:40:06.202 CNTRLR « [Node 031] parameter #13 has value: 0 09:40:06.202 CNTRLR » [Node 031] querying parameter #14 value... 09:40:06.206 SERIAL « [ACK] (0x06) 09:40:06.210 SERIAL « 0x0104011301e8 (6 bytes) 09:40:06.210 SERIAL » [ACK] (0x06) 09:40:06.211 DRIVER « [RES] [SendData] was sent: true 09:40:06.231 SERIAL « 0x01070013ca00000223 (9 bytes) 09:40:06.231 SERIAL » [ACK] (0x06) 09:40:06.231 DRIVER « [REQ] [SendData] callback id: 202 transmit status: OK 09:40:06.244 SERIAL « 0x010b00040018057006280103b1 (13 bytes) 09:40:06.249 CNTRLR [Node 024] [~] [Configuration] 40: 3 => 3 09:40:06.250 SERIAL » [ACK] (0x06) 09:40:06.251 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 3 09:40:06.254 SERIAL » 0x010a00131f0370050e25cb6f (12 bytes) 09:40:06.254 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 203 └─[ConfigurationCCGet] parameter #: 14 09:40:06.255 CNTRLR « [Node 024] parameter #40 has value: 3 09:40:06.255 CNTRLR » [Node 024] querying parameter #41 value... 09:40:06.258 SERIAL « [ACK] (0x06) 09:40:06.263 SERIAL « 0x0104011301e8 (6 bytes) 09:40:06.263 SERIAL » [ACK] (0x06) 09:40:06.263 DRIVER « [RES] [SendData] was sent: true 09:40:06.280 SERIAL « 0x01070013cb00000222 (9 bytes) 09:40:06.280 SERIAL » [ACK] (0x06) 09:40:06.280 DRIVER « [REQ] [SendData] callback id: 203 transmit status: OK 09:40:06.290 SERIAL « 0x010b0004001f0570060e010192 (13 bytes) 09:40:06.301 CNTRLR [Node 031] [~] [Configuration] 14: 1 => 1 09:40:06.302 SERIAL » [ACK] (0x06) 09:40:06.303 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 1 09:40:06.306 SERIAL » 0x010a0013180370052925cc48 (12 bytes) 09:40:06.306 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 204 └─[ConfigurationCCGet] parameter #: 41 09:40:06.306 CNTRLR « [Node 031] parameter #14 has value: 1 09:40:06.307 CNTRLR » [Node 031] querying parameter #15 value... 09:40:06.310 SERIAL « [ACK] (0x06) 09:40:06.315 SERIAL « 0x0104011301e8 (6 bytes) 09:40:06.315 SERIAL » [ACK] (0x06) 09:40:06.316 DRIVER « [RES] [SendData] was sent: true 09:40:06.336 SERIAL « 0x01070013cc00000324 (9 bytes) 09:40:06.336 SERIAL » [ACK] (0x06) 09:40:06.336 DRIVER « [REQ] [SendData] callback id: 204 transmit status: OK 09:40:06.350 SERIAL « 0x010b00040018057006290102b1 (13 bytes) 09:40:06.355 CNTRLR [Node 024] [~] [Configuration] 41: 2 => 2 09:40:06.356 SERIAL » [ACK] (0x06) 09:40:06.357 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 41 value size: 1 value: 2 09:40:06.359 SERIAL » 0x010a00131f0370050f25cd68 (12 bytes) 09:40:06.360 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 205 └─[ConfigurationCCGet] parameter #: 15 09:40:06.360 CNTRLR « [Node 024] parameter #41 has value: 2 09:40:06.360 CNTRLR » [Node 024] querying parameter #42 value... 09:40:06.369 SERIAL « [ACK] (0x06) 09:40:06.371 SERIAL « 0x0104011301e8 (6 bytes) 09:40:06.372 SERIAL » [ACK] (0x06) 09:40:06.372 DRIVER « [RES] [SendData] was sent: true 09:40:06.385 SERIAL « 0x01070013cd00000224 (9 bytes) 09:40:06.385 SERIAL » [ACK] (0x06) 09:40:06.385 DRIVER « [REQ] [SendData] callback id: 205 transmit status: OK 09:40:06.395 SERIAL « 0x010b0004001f0570060f010092 (13 bytes) 09:40:06.401 CNTRLR [Node 031] [~] [Configuration] 15: 0 => 0 09:40:06.401 SERIAL » [ACK] (0x06) 09:40:06.402 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 15 value size: 1 value: 0 09:40:06.405 SERIAL » 0x010a0013180370052a25ce49 (12 bytes) 09:40:06.406 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 206 └─[ConfigurationCCGet] parameter #: 42 09:40:06.406 CNTRLR « [Node 031] parameter #15 has value: 0 09:40:06.406 CNTRLR » [Node 031] querying parameter #16 value... 09:40:06.409 SERIAL « [ACK] (0x06) 09:40:06.415 SERIAL « 0x0104011301e8 (6 bytes) 09:40:06.415 SERIAL » [ACK] (0x06) 09:40:06.415 DRIVER « [RES] [SendData] was sent: true 09:40:06.434 SERIAL « 0x01070013ce00000326 (9 bytes) 09:40:06.435 SERIAL » [ACK] (0x06) 09:40:06.435 DRIVER « [REQ] [SendData] callback id: 206 transmit status: OK 09:40:06.448 SERIAL « 0x010b000400180570062a0103b3 (13 bytes) 09:40:06.453 CNTRLR [Node 024] [~] [Configuration] 42: 3 => 3 09:40:06.454 SERIAL » [ACK] (0x06) 09:40:06.455 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 3 09:40:06.458 SERIAL » 0x010a00131f0370051025cf75 (12 bytes) 09:40:06.460 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 207 └─[ConfigurationCCGet] parameter #: 16 09:40:06.460 CNTRLR « [Node 024] parameter #42 has value: 3 09:40:06.460 CNTRLR » [Node 024] querying parameter #43 value... 09:40:06.463 SERIAL « [ACK] (0x06) 09:40:06.469 SERIAL « 0x0104011301e8 (6 bytes) 09:40:06.469 SERIAL » [ACK] (0x06) 09:40:06.469 DRIVER « [RES] [SendData] was sent: true 09:40:06.485 SERIAL « 0x01070013cf00000226 (9 bytes) 09:40:06.485 SERIAL » [ACK] (0x06) 09:40:06.486 DRIVER « [REQ] [SendData] callback id: 207 transmit status: OK 09:40:06.495 SERIAL « 0x010b0004001f0570061001018c (13 bytes) 09:40:06.503 CNTRLR [Node 031] [~] [Configuration] 16: 1 => 1 09:40:06.504 SERIAL » [ACK] (0x06) 09:40:06.505 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 1 09:40:06.508 SERIAL » 0x010a0013180370052b25d056 (12 bytes) 09:40:06.508 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 208 └─[ConfigurationCCGet] parameter #: 43 09:40:06.509 CNTRLR « [Node 031] parameter #16 has value: 1 09:40:06.509 CNTRLR » [Node 031] querying parameter #30 value... 09:40:06.512 SERIAL « [ACK] (0x06) 09:40:06.517 SERIAL « 0x0104011301e8 (6 bytes) 09:40:06.517 SERIAL » [ACK] (0x06) 09:40:06.518 DRIVER « [RES] [SendData] was sent: true 09:40:06.537 SERIAL « 0x01070013d000000338 (9 bytes) 09:40:06.538 SERIAL » [ACK] (0x06) 09:40:06.538 DRIVER « [REQ] [SendData] callback id: 208 transmit status: OK 09:40:06.551 SERIAL « 0x010b000400180570062b0101b0 (13 bytes) 09:40:06.556 CNTRLR [Node 024] [~] [Configuration] 43: 1 => 1 09:40:06.557 SERIAL » [ACK] (0x06) 09:40:06.558 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 1 09:40:06.564 SERIAL » 0x010a00131f0370051e25d165 (12 bytes) 09:40:06.564 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 209 └─[ConfigurationCCGet] parameter #: 30 09:40:06.564 CNTRLR « [Node 024] parameter #43 has value: 1 09:40:06.565 CNTRLR » [Node 024] querying parameter #44 value... 09:40:06.568 SERIAL « [ACK] (0x06) 09:40:06.573 SERIAL « 0x0104011301e8 (6 bytes) 09:40:06.573 SERIAL » [ACK] (0x06) 09:40:06.574 DRIVER « [RES] [SendData] was sent: true 09:40:06.589 SERIAL « 0x01070013d100000238 (9 bytes) 09:40:06.590 SERIAL » [ACK] (0x06) 09:40:06.590 DRIVER « [REQ] [SendData] callback id: 209 transmit status: OK 09:40:06.600 SERIAL « 0x010b0004001f0570061e010380 (13 bytes) 09:40:06.605 CNTRLR [Node 031] [~] [Configuration] 30: 3 => 3 09:40:06.606 SERIAL » [ACK] (0x06) 09:40:06.607 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 3 09:40:06.610 SERIAL » 0x010a0013180370052c25d253 (12 bytes) 09:40:06.610 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 210 └─[ConfigurationCCGet] parameter #: 44 09:40:06.610 CNTRLR « [Node 031] parameter #30 has value: 3 09:40:06.611 CNTRLR » [Node 031] querying parameter #31 value... 09:40:06.614 SERIAL « [ACK] (0x06) 09:40:06.620 SERIAL « 0x0104011301e8 (6 bytes) 09:40:06.620 SERIAL » [ACK] (0x06) 09:40:06.622 DRIVER « [RES] [SendData] was sent: true 09:40:06.662 SERIAL « 0x01070013d20000023b (9 bytes) 09:40:06.663 SERIAL » [ACK] (0x06) 09:40:06.663 DRIVER « [REQ] [SendData] callback id: 210 transmit status: OK 09:40:06.672 SERIAL « 0x010c000400180670062c020258eb (14 bytes) 09:40:06.678 CNTRLR [Node 024] [~] [Configuration] 44: 600 => 600 09:40:06.679 SERIAL » [ACK] (0x06) 09:40:06.683 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 44 value size: 2 value: 600 09:40:06.686 SERIAL » 0x010a00131f0370051f25d366 (12 bytes) 09:40:06.687 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 211 └─[ConfigurationCCGet] parameter #: 31 09:40:06.687 CNTRLR « [Node 024] parameter #44 has value: 600 09:40:06.687 CNTRLR » [Node 024] querying parameter #50 value... 09:40:06.691 SERIAL « [ACK] (0x06) 09:40:06.695 SERIAL « 0x0104011301e8 (6 bytes) 09:40:06.696 SERIAL » [ACK] (0x06) 09:40:06.696 DRIVER « [RES] [SendData] was sent: true 09:40:06.712 SERIAL « 0x01070013d30000033b (9 bytes) 09:40:06.712 SERIAL » [ACK] (0x06) 09:40:06.713 DRIVER « [REQ] [SendData] callback id: 211 transmit status: OK 09:40:06.724 SERIAL « 0x010b0004001f0570061f010280 (13 bytes) 09:40:06.729 CNTRLR [Node 031] [~] [Configuration] 31: 2 => 2 09:40:06.730 SERIAL » [ACK] (0x06) 09:40:06.731 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 2 09:40:06.734 SERIAL » 0x010a0013180370053225d44b (12 bytes) 09:40:06.734 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 212 └─[ConfigurationCCGet] parameter #: 50 09:40:06.734 CNTRLR « [Node 031] parameter #31 has value: 2 09:40:06.734 CNTRLR » [Node 031] querying parameter #32 value... 09:40:06.738 SERIAL « [ACK] (0x06) 09:40:06.743 SERIAL « 0x0104011301e8 (6 bytes) 09:40:06.743 SERIAL » [ACK] (0x06) 09:40:06.744 DRIVER « [RES] [SendData] was sent: true 09:40:06.763 SERIAL « 0x01070013d40000033c (9 bytes) 09:40:06.763 SERIAL » [ACK] (0x06) 09:40:06.764 DRIVER « [REQ] [SendData] callback id: 212 transmit status: OK 09:40:06.777 SERIAL « 0x010b00040018057006320114bc (13 bytes) 09:40:06.782 CNTRLR [Node 024] [~] [Configuration] 50: 20 => 20 09:40:06.783 SERIAL » [ACK] (0x06) 09:40:06.784 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 20 09:40:06.789 SERIAL » 0x010a00131f0370052025d55f (12 bytes) 09:40:06.789 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 213 └─[ConfigurationCCGet] parameter #: 32 09:40:06.789 CNTRLR « [Node 024] parameter #50 has value: 20 09:40:06.790 CNTRLR » [Node 024] querying parameter #51 value... 09:40:06.793 SERIAL « [ACK] (0x06) 09:40:06.798 SERIAL « 0x0104011301e8 (6 bytes) 09:40:06.798 SERIAL » [ACK] (0x06) 09:40:06.798 DRIVER « [RES] [SendData] was sent: true 09:40:06.814 SERIAL « 0x01070013d50000023c (9 bytes) 09:40:06.815 SERIAL » [ACK] (0x06) 09:40:06.815 DRIVER « [REQ] [SendData] callback id: 213 transmit status: OK 09:40:06.826 SERIAL « 0x010b0004001f057006200103be (13 bytes) 09:40:06.831 CNTRLR [Node 031] [~] [Configuration] 32: 3 => 3 09:40:06.832 SERIAL » [ACK] (0x06) 09:40:06.833 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 1 value: 3 09:40:06.836 SERIAL » 0x010a0013180370053325d648 (12 bytes) 09:40:06.836 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 214 └─[ConfigurationCCGet] parameter #: 51 09:40:06.836 CNTRLR « [Node 031] parameter #32 has value: 3 09:40:06.836 CNTRLR » [Node 031] querying parameter #33 value... 09:40:06.839 SERIAL « [ACK] (0x06) 09:40:06.848 SERIAL « 0x0104011301e8 (6 bytes) 09:40:06.849 SERIAL » [ACK] (0x06) 09:40:06.849 DRIVER « [RES] [SendData] was sent: true 09:40:06.857 SERIAL « 0x01090004001b033003ff26 (11 bytes) 09:40:06.858 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:40:06.858 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:40:06.859 SERIAL » [ACK] (0x06) 09:40:06.860 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:40:06.908 SERIAL « 0x01070013d60000073a (9 bytes) 09:40:06.908 SERIAL » [ACK] (0x06) 09:40:06.909 DRIVER « [REQ] [SendData] callback id: 214 transmit status: OK 09:40:06.922 SERIAL « 0x010b0004001805700633010aa3 (13 bytes) 09:40:06.930 CNTRLR [Node 024] [~] [Configuration] 51: 10 => 10 09:40:06.931 SERIAL » [ACK] (0x06) 09:40:06.932 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 51 value size: 1 value: 10 09:40:06.936 SERIAL » 0x010a00131f0370052125d75c (12 bytes) 09:40:06.937 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 215 └─[ConfigurationCCGet] parameter #: 33 09:40:06.937 CNTRLR « [Node 024] parameter #51 has value: 10 09:40:06.937 CNTRLR » [Node 024] querying parameter #53 value... 09:40:06.941 SERIAL « [ACK] (0x06) 09:40:06.945 SERIAL « 0x0104011301e8 (6 bytes) 09:40:06.945 SERIAL » [ACK] (0x06) 09:40:06.946 DRIVER « [RES] [SendData] was sent: true 09:40:06.962 SERIAL « 0x01070013d70000033f (9 bytes) 09:40:06.962 SERIAL » [ACK] (0x06) 09:40:06.963 DRIVER « [REQ] [SendData] callback id: 215 transmit status: OK 09:40:06.973 SERIAL « 0x010b0004001f057006210101bd (13 bytes) 09:40:06.980 CNTRLR [Node 031] [~] [Configuration] 33: 1 => 1 09:40:06.981 SERIAL » [ACK] (0x06) 09:40:06.983 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 1 value: 1 09:40:06.986 SERIAL » 0x010a0013180370053525d840 (12 bytes) 09:40:06.987 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 216 └─[ConfigurationCCGet] parameter #: 53 09:40:06.987 CNTRLR « [Node 031] parameter #33 has value: 1 09:40:06.988 CNTRLR » [Node 031] querying parameter #39 value... 09:40:06.991 SERIAL « [ACK] (0x06) 09:40:06.995 SERIAL « 0x0104011301e8 (6 bytes) 09:40:06.995 SERIAL » [ACK] (0x06) 09:40:06.996 DRIVER « [RES] [SendData] was sent: true 09:40:07.016 SERIAL « 0x01070013d800000330 (9 bytes) 09:40:07.016 SERIAL » [ACK] (0x06) 09:40:07.017 DRIVER « [REQ] [SendData] callback id: 216 transmit status: OK 09:40:07.030 SERIAL « 0x010c0004001806700635020064cc (14 bytes) 09:40:07.038 CNTRLR [Node 024] [~] [Configuration] 53: 100 => 100 09:40:07.039 SERIAL » [ACK] (0x06) 09:40:07.042 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 53 value size: 2 value: 100 09:40:07.046 SERIAL » 0x010a00131f0370052725d954 (12 bytes) 09:40:07.046 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 217 └─[ConfigurationCCGet] parameter #: 39 09:40:07.047 CNTRLR « [Node 024] parameter #53 has value: 100 09:40:07.047 CNTRLR » [Node 024] querying parameter #54 value... 09:40:07.050 SERIAL « [ACK] (0x06) 09:40:07.054 SERIAL « 0x0104011301e8 (6 bytes) 09:40:07.055 SERIAL » [ACK] (0x06) 09:40:07.055 DRIVER « [RES] [SendData] was sent: true 09:40:07.071 SERIAL « 0x01070013d900000230 (9 bytes) 09:40:07.072 SERIAL » [ACK] (0x06) 09:40:07.072 DRIVER « [REQ] [SendData] callback id: 217 transmit status: OK 09:40:07.083 SERIAL « 0x010c0004001f06700627020258e7 (14 bytes) 09:40:07.088 CNTRLR [Node 031] [~] [Configuration] 39: 600 => 600 09:40:07.089 SERIAL » [ACK] (0x06) 09:40:07.089 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 39 value size: 2 value: 600 09:40:07.092 SERIAL » 0x010a0013180370053625da41 (12 bytes) 09:40:07.093 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 218 └─[ConfigurationCCGet] parameter #: 54 09:40:07.093 CNTRLR « [Node 031] parameter #39 has value: 600 09:40:07.093 CNTRLR » [Node 031] querying parameter #40 value... 09:40:07.099 SERIAL « [ACK] (0x06) 09:40:07.101 SERIAL « 0x0104011301e8 (6 bytes) 09:40:07.101 SERIAL » [ACK] (0x06) 09:40:07.102 DRIVER « [RES] [SendData] was sent: true 09:40:07.122 SERIAL « 0x01070013da00000233 (9 bytes) 09:40:07.122 SERIAL » [ACK] (0x06) 09:40:07.123 DRIVER « [REQ] [SendData] callback id: 218 transmit status: OK 09:40:07.135 SERIAL « 0x010b00040018057006360114b8 (13 bytes) 09:40:07.140 CNTRLR [Node 024] [~] [Configuration] 54: 20 => 20 09:40:07.142 SERIAL » [ACK] (0x06) 09:40:07.143 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 54 value size: 1 value: 20 09:40:07.145 SERIAL » 0x010a00131f0370052825db59 (12 bytes) 09:40:07.146 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 219 └─[ConfigurationCCGet] parameter #: 40 09:40:07.146 CNTRLR « [Node 024] parameter #54 has value: 20 09:40:07.146 CNTRLR » [Node 024] querying parameter #55 value... 09:40:07.152 SERIAL « [ACK] (0x06) 09:40:07.156 SERIAL « 0x0104011301e8 (6 bytes) 09:40:07.156 SERIAL » [ACK] (0x06) 09:40:07.158 DRIVER « [RES] [SendData] was sent: true 09:40:07.171 SERIAL « 0x01070013db00000232 (9 bytes) 09:40:07.171 SERIAL » [ACK] (0x06) 09:40:07.171 DRIVER « [REQ] [SendData] callback id: 219 transmit status: OK 09:40:07.182 SERIAL « 0x010b0004001f057006280103b6 (13 bytes) 09:40:07.187 CNTRLR [Node 031] [~] [Configuration] 40: 3 => 3 09:40:07.188 SERIAL » [ACK] (0x06) 09:40:07.189 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 3 09:40:07.192 SERIAL » 0x010a0013180370053725dc46 (12 bytes) 09:40:07.193 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 220 └─[ConfigurationCCGet] parameter #: 55 09:40:07.193 CNTRLR « [Node 031] parameter #40 has value: 3 09:40:07.193 CNTRLR » [Node 031] querying parameter #41 value... 09:40:07.196 SERIAL « [ACK] (0x06) 09:40:07.203 SERIAL « 0x0104011301e8 (6 bytes) 09:40:07.204 SERIAL » [ACK] (0x06) 09:40:07.204 DRIVER « [RES] [SendData] was sent: true 09:40:07.222 SERIAL « 0x01070013dc00000334 (9 bytes) 09:40:07.222 SERIAL » [ACK] (0x06) 09:40:07.223 DRIVER « [REQ] [SendData] callback id: 220 transmit status: OK 09:40:07.235 SERIAL « 0x010b0004001805700637010aa7 (13 bytes) 09:40:07.241 CNTRLR [Node 024] [~] [Configuration] 55: 10 => 10 09:40:07.241 SERIAL » [ACK] (0x06) 09:40:07.242 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 55 value size: 1 value: 10 09:40:07.249 SERIAL » 0x010a00131f0370052925dd5e (12 bytes) 09:40:07.249 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 221 └─[ConfigurationCCGet] parameter #: 41 09:40:07.249 CNTRLR « [Node 024] parameter #55 has value: 10 09:40:07.249 CNTRLR » [Node 024] querying parameter #57 value... 09:40:07.253 SERIAL « [ACK] (0x06) 09:40:07.257 SERIAL « 0x0104011301e8 (6 bytes) 09:40:07.257 SERIAL » [ACK] (0x06) 09:40:07.258 DRIVER « [RES] [SendData] was sent: true 09:40:07.274 SERIAL « 0x01070013dd00000234 (9 bytes) 09:40:07.275 SERIAL » [ACK] (0x06) 09:40:07.275 DRIVER « [REQ] [SendData] callback id: 221 transmit status: OK 09:40:07.285 SERIAL « 0x010b0004001f057006290102b6 (13 bytes) 09:40:07.290 CNTRLR [Node 031] [~] [Configuration] 41: 2 => 2 09:40:07.291 SERIAL » [ACK] (0x06) 09:40:07.292 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 41 value size: 1 value: 2 09:40:07.294 SERIAL » 0x010a0013180370053925de4a (12 bytes) 09:40:07.295 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 222 └─[ConfigurationCCGet] parameter #: 57 09:40:07.295 CNTRLR « [Node 031] parameter #41 has value: 2 09:40:07.295 CNTRLR » [Node 031] querying parameter #42 value... 09:40:07.298 SERIAL « [ACK] (0x06) 09:40:07.304 SERIAL « 0x0104011301e8 (6 bytes) 09:40:07.304 SERIAL » [ACK] (0x06) 09:40:07.305 DRIVER « [RES] [SendData] was sent: true 09:40:07.324 SERIAL « 0x01070013de00000336 (9 bytes) 09:40:07.325 SERIAL » [ACK] (0x06) 09:40:07.325 DRIVER « [REQ] [SendData] callback id: 222 transmit status: OK 09:40:07.338 SERIAL « 0x010c0004001806700639020064c0 (14 bytes) 09:40:07.344 CNTRLR [Node 024] [~] [Configuration] 57: 100 => 100 09:40:07.345 SERIAL » [ACK] (0x06) 09:40:07.347 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 57 value size: 2 value: 100 09:40:07.351 SERIAL » 0x010a00131f0370052a25df5f (12 bytes) 09:40:07.351 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 223 └─[ConfigurationCCGet] parameter #: 42 09:40:07.352 CNTRLR « [Node 024] parameter #57 has value: 100 09:40:07.352 CNTRLR » [Node 024] querying parameter #58 value... 09:40:07.360 SERIAL « [ACK] (0x06) 09:40:07.362 SERIAL « 0x0104011301e8 (6 bytes) 09:40:07.362 SERIAL » [ACK] (0x06) 09:40:07.362 DRIVER « [RES] [SendData] was sent: true 09:40:07.376 SERIAL « 0x01070013df00000236 (9 bytes) 09:40:07.377 SERIAL » [ACK] (0x06) 09:40:07.377 DRIVER « [REQ] [SendData] callback id: 223 transmit status: OK 09:40:07.388 SERIAL « 0x010b0004001f0570062a0103b4 (13 bytes) 09:40:07.398 CNTRLR [Node 031] [~] [Configuration] 42: 3 => 3 09:40:07.399 SERIAL » [ACK] (0x06) 09:40:07.400 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 3 09:40:07.402 SERIAL » 0x010a0013180370053a25e077 (12 bytes) 09:40:07.403 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 224 └─[ConfigurationCCGet] parameter #: 58 09:40:07.403 CNTRLR « [Node 031] parameter #42 has value: 3 09:40:07.403 CNTRLR » [Node 031] querying parameter #43 value... 09:40:07.407 SERIAL « [ACK] (0x06) 09:40:07.411 SERIAL « 0x0104011301e8 (6 bytes) 09:40:07.412 SERIAL » [ACK] (0x06) 09:40:07.412 DRIVER « [RES] [SendData] was sent: true 09:40:07.432 SERIAL « 0x01070013e000000209 (9 bytes) 09:40:07.432 SERIAL » [ACK] (0x06) 09:40:07.432 DRIVER « [REQ] [SendData] callback id: 224 transmit status: OK 09:40:07.446 SERIAL « 0x010c000400180670063a020e10b9 (14 bytes) 09:40:07.451 CNTRLR [Node 024] [~] [Configuration] 58: 3600 => 3600 09:40:07.452 SERIAL » [ACK] (0x06) 09:40:07.452 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 58 value size: 2 value: 3600 09:40:07.455 SERIAL » 0x010a00131f0370052b25e160 (12 bytes) 09:40:07.456 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 225 └─[ConfigurationCCGet] parameter #: 43 09:40:07.456 CNTRLR « [Node 024] parameter #58 has value: 3600 09:40:07.456 CNTRLR » [Node 024] querying parameter #59 value... 09:40:07.459 SERIAL « [ACK] (0x06) 09:40:07.465 SERIAL « 0x0104011301e8 (6 bytes) 09:40:07.465 SERIAL » [ACK] (0x06) 09:40:07.466 DRIVER « [RES] [SendData] was sent: true 09:40:07.481 SERIAL « 0x01070013e100000208 (9 bytes) 09:40:07.481 SERIAL » [ACK] (0x06) 09:40:07.481 DRIVER « [REQ] [SendData] callback id: 225 transmit status: OK 09:40:07.491 SERIAL « 0x010b0004001f0570062b0101b7 (13 bytes) 09:40:07.497 CNTRLR [Node 031] [~] [Configuration] 43: 1 => 1 09:40:07.497 SERIAL » [ACK] (0x06) 09:40:07.498 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 1 09:40:07.501 SERIAL » 0x010a0013180370053b25e274 (12 bytes) 09:40:07.501 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 226 └─[ConfigurationCCGet] parameter #: 59 09:40:07.501 CNTRLR « [Node 031] parameter #43 has value: 1 09:40:07.502 CNTRLR [Node 031] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 09:40:07.537 SERIAL « [ACK] (0x06) 09:40:07.538 SERIAL « 0x0104011301e8 (6 bytes) 09:40:07.538 SERIAL » [ACK] (0x06) 09:40:07.538 DRIVER « [RES] [SendData] was sent: true 09:40:07.541 CNTRLR [Node 031] MultiChannelAssociationCC: doing a partial interview... 09:40:07.541 CNTRLR » [Node 031] querying multi channel association group #1... 09:40:07.545 SERIAL « 0x01070013e20000020b (9 bytes) 09:40:07.545 SERIAL » [ACK] (0x06) 09:40:07.546 DRIVER « [REQ] [SendData] callback id: 226 transmit status: OK 09:40:07.548 SERIAL « 0x010c000400180670063b020e10b8 (14 bytes) 09:40:07.556 CNTRLR [Node 024] [~] [Configuration] 59: 3600 => 3600 09:40:07.557 SERIAL » [ACK] (0x06) 09:40:07.557 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 59 value size: 2 value: 3600 09:40:07.560 SERIAL » 0x0108001320010025e303 (10 bytes) 09:40:07.560 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 227 └─[NoOperationCC] 09:40:07.561 CNTRLR « [Node 024] parameter #59 has value: 3600 09:40:07.561 CNTRLR » [Node 024] querying parameter #60 value... 09:40:07.564 SERIAL « [ACK] (0x06) 09:40:07.568 SERIAL « 0x0104011301e8 (6 bytes) 09:40:07.568 SERIAL » [ACK] (0x06) 09:40:07.569 DRIVER « [RES] [SendData] was sent: true 09:40:07.683 SERIAL « 0x01090004001b032001ff34 (11 bytes) 09:40:07.683 SERIAL » [ACK] (0x06) 09:40:07.684 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:40:07.685 CNTRLR [Node 027] treating BasicCC Set as a report 09:40:07.685 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:40:07.787 SERIAL « 0x01090004001b032001ff34 (11 bytes) 09:40:07.787 SERIAL » [ACK] (0x06) 09:40:07.788 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:40:07.789 CNTRLR [Node 027] treating BasicCC Set as a report 09:40:07.790 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:40:10.353 SERIAL « 0x010c00040003063105042208c52d (14 bytes) 09:40:10.354 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:40:10.355 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 115.9 => 224.5 [Endpoint 0] 09:40:10.355 SERIAL » [ACK] (0x06) 09:40:10.356 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 224.5 09:40:10.406 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 09:40:10.407 SERIAL » [ACK] (0x06) 09:40:10.407 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 09:40:10.409 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 09:40:11.353 SERIAL « 0x010c0004000306310504220447a3 (14 bytes) 09:40:11.354 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:40:11.355 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 224.5 => 109.5 [Endpoint 0] 09:40:11.355 SERIAL » [ACK] (0x06) 09:40:11.356 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 109.5 09:40:12.227 SERIAL « 0x01070013e30101d2da (9 bytes) 09:40:12.227 SERIAL » [ACK] (0x06) 09:40:12.228 DRIVER « [REQ] [SendData] callback id: 227 transmit status: NoAck 09:40:12.232 SERIAL » 0x0108001321010025e405 (10 bytes) 09:40:12.232 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 228 └─[NoOperationCC] 09:40:12.233 CNTRLR [Node 032] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 09:40:12.233 CNTRLR [Node 032] The node is asleep. 09:40:12.234 CNTRLR [Node 032] The node is ready to be used 09:40:12.235 CNTRLR [Node 032] ping failed: Failed to send the command after 1 attempts (Status No Ack) 09:40:12.237 CNTRLR [Node 032] ManufacturerSpecificCC: doing a partial interview... 09:40:12.237 CNTRLR [Node 032] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:40:12.268 SERIAL « [ACK] (0x06) 09:40:12.269 SERIAL « 0x0104011301e8 (6 bytes) 09:40:12.270 SERIAL » [ACK] (0x06) 09:40:12.272 DRIVER « [RES] [SendData] was sent: true 09:40:12.275 SERIAL « 0x01070013e40000020d (9 bytes) 09:40:12.276 SERIAL » [ACK] (0x06) 09:40:12.276 CNTRLR [Node 032] VersionCC: doing a partial interview... 09:40:12.277 CNTRLR [Node 032] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:40:12.277 CNTRLR [Node 032] trying to load device config 09:40:12.278 DRIVER « [REQ] [SendData] callback id: 228 transmit status: OK 09:40:12.282 SERIAL » 0x0108001322010025e507 (10 bytes) 09:40:12.282 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 229 └─[NoOperationCC] 09:40:12.282 CNTRLR « [Node 033] ping successful 09:40:12.284 CNTRLR [Node 033] ManufacturerSpecificCC: doing a partial interview... 09:40:12.284 CNTRLR [Node 033] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:40:12.284 CNTRLR [Node 033] VersionCC: doing a partial interview... 09:40:12.285 CNTRLR [Node 033] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:40:12.285 CNTRLR [Node 033] trying to load device config 09:40:12.287 SERIAL « [ACK] (0x06) 09:40:12.301 CNTRLR [Node 032] device config loaded 09:40:12.301 CNTRLR [Node 032] BatteryCC: doing a partial interview... 09:40:12.301 CNTRLR » [Node 032] querying battery status... 09:40:12.310 CNTRLR [Node 033] device config loaded 09:40:12.310 CNTRLR » [Node 033] querying device endpoint information... 09:40:12.312 SERIAL « 0x0104011301e8 (6 bytes) 09:40:12.312 SERIAL » [ACK] (0x06) 09:40:12.316 DRIVER « [RES] [SendData] was sent: true 09:40:12.318 SERIAL « 0x01070013e50000020c (9 bytes) 09:40:12.318 SERIAL » [ACK] (0x06) 09:40:12.318 DRIVER « [REQ] [SendData] callback id: 229 transmit status: OK 09:40:12.326 SERIAL » 0x0108001323010025e605 (10 bytes) 09:40:12.326 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 230 └─[NoOperationCC] 09:40:12.326 CNTRLR « [Node 034] ping successful 09:40:12.329 CNTRLR [Node 034] ManufacturerSpecificCC: doing a partial interview... 09:40:12.329 CNTRLR [Node 034] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:40:12.329 CNTRLR [Node 034] VersionCC: doing a partial interview... 09:40:12.330 CNTRLR [Node 034] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:40:12.330 CNTRLR [Node 034] trying to load device config 09:40:12.333 SERIAL « [ACK] (0x06) 09:40:12.334 SERIAL « 0x0104011301e8 (6 bytes) 09:40:12.335 SERIAL » [ACK] (0x06) 09:40:12.336 DRIVER « [RES] [SendData] was sent: true 09:40:12.352 CNTRLR [Node 034] device config loaded 09:40:12.353 CNTRLR [Node 034] ZWavePlusCC: doing a partial interview... 09:40:12.353 CNTRLR [Node 034] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:40:12.353 CNTRLR » [Node 034] querying device endpoint information... 09:40:12.647 SERIAL « 0x010c000400030631050422083ad2 (14 bytes) 09:40:12.648 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:40:12.649 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 109.5 => 210.6 [Endpoint 0] 09:40:12.649 SERIAL » [ACK] (0x06) 09:40:12.651 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 210.6 09:40:13.907 SERIAL « 0x01070013e600007f72 (9 bytes) 09:40:13.908 SERIAL » [ACK] (0x06) 09:40:13.914 DRIVER « [REQ] [SendData] callback id: 230 transmit status: OK 09:40:13.923 SERIAL » 0x010900132102600725e763 (11 bytes) 09:40:13.923 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 231 └─[MultiChannelCCEndPointGet] 09:40:13.924 CNTRLR « [Node 035] ping successful 09:40:13.928 CNTRLR [Node 035] ManufacturerSpecificCC: doing a partial interview... 09:40:13.929 CNTRLR [Node 035] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:40:13.929 CNTRLR [Node 035] VersionCC: doing a partial interview... 09:40:13.930 CNTRLR [Node 035] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:40:13.930 CNTRLR [Node 035] trying to load device config 09:40:13.936 SERIAL « 0x010c00040003063105042203fb18 (14 bytes) 09:40:13.937 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:40:13.939 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 210.6 => 101.9 [Endpoint 0] 09:40:13.940 SERIAL » [ACK] (0x06) 09:40:13.940 SERIAL « [CAN] (0x18) 09:40:13.942 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 09:40:13.945 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 101.9 09:40:13.953 CNTRLR [Node 035] device config loaded 09:40:13.953 CNTRLR [Node 035] ZWavePlusCC: doing a partial interview... 09:40:13.954 CNTRLR [Node 035] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 09:40:13.955 CNTRLR » [Node 035] querying device endpoint information... 09:40:14.043 SERIAL » 0x010900132102600725e763 (11 bytes) 09:40:14.043 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 231 └─[MultiChannelCCEndPointGet] 09:40:14.044 SERIAL « [ACK] (0x06) 09:40:14.051 SERIAL « 0x0104011301e8 (6 bytes) 09:40:14.051 SERIAL » [ACK] (0x06) 09:40:14.052 DRIVER « [RES] [SendData] was sent: true 09:40:14.068 SERIAL « 0x01070013e70000020e (9 bytes) 09:40:14.069 SERIAL » [ACK] (0x06) 09:40:14.069 DRIVER « [REQ] [SendData] callback id: 231 transmit status: OK 09:40:14.079 SERIAL « 0x010a000400210460084005f9 (12 bytes) 09:40:14.079 CNTRLR [Node 033] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:40:14.080 CNTRLR [Node 033] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 09:40:14.080 CNTRLR [Node 033] [~] [Multi Channel] individualCount: 5 => 5 [Endpoint 0] [internal] 09:40:14.080 SERIAL » [ACK] (0x06) 09:40:14.081 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 5 count is dynamic: false identical capabilities: true 09:40:14.084 SERIAL » 0x010a001303038e020125e8a6 (12 bytes) 09:40:14.084 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 232 └─[MultiChannelAssociationCCGet] group id: 1 09:40:14.085 CNTRLR « [Node 033] received response for device endpoints: endpoint count (individual): 5 count is dynamic: false identical capabilities: true 09:40:14.085 CNTRLR » [Node 033] querying all endpoints... 09:40:14.088 SERIAL « [ACK] (0x06) 09:40:14.092 SERIAL « 0x0104011301e8 (6 bytes) 09:40:14.093 SERIAL » [ACK] (0x06) 09:40:14.093 DRIVER « [RES] [SendData] was sent: true 09:40:14.133 SERIAL « 0x01090004001e033003ff23 (11 bytes) 09:40:14.133 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:40:14.134 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:40:14.134 SERIAL » [ACK] (0x06) 09:40:14.135 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:40:14.175 SERIAL « 0x01090004001e032001ff31 (11 bytes) 09:40:14.175 SERIAL » [ACK] (0x06) 09:40:14.176 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:40:14.177 CNTRLR [Node 030] treating BasicCC Set as a report 09:40:14.177 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:40:14.180 SERIAL « 0x01070013e80000090a (9 bytes) 09:40:14.180 SERIAL » [ACK] (0x06) 09:40:14.181 DRIVER « [REQ] [SendData] callback id: 232 transmit status: OK 09:40:14.190 SERIAL « 0x010b00040003058e030105007f (13 bytes) 09:40:14.190 SERIAL » [ACK] (0x06) 09:40:14.191 CNTRLR [Node 003] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 09:40:14.192 CNTRLR [Node 003] [~] [Multi Channel Association] nodeIds[1]: => 09:40:14.193 CNTRLR [Node 003] [~] [Multi Channel Association] endpoints[1]: => 09:40:14.194 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: endpoints: 09:40:14.197 SERIAL » 0x010b00132104600bffff25e965 (13 bytes) 09:40:14.197 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 233 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:40:14.198 CNTRLR « [Node 003] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 09:40:14.198 CNTRLR » [Node 003] querying multi channel association group #2... 09:40:14.201 SERIAL « [ACK] (0x06) 09:40:14.207 SERIAL « 0x0104011301e8 (6 bytes) 09:40:14.207 SERIAL » [ACK] (0x06) 09:40:14.209 DRIVER « [RES] [SendData] was sent: true 09:40:14.223 SERIAL « 0x01070013e900000301 (9 bytes) 09:40:14.224 SERIAL » [ACK] (0x06) 09:40:14.224 DRIVER « [REQ] [SendData] callback id: 233 transmit status: OK 09:40:14.234 SERIAL « 0x010c0004002106600c00ffff00bc (14 bytes) 09:40:14.235 SERIAL » [ACK] (0x06) 09:40:14.236 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: # of reports to follow: 0 09:40:14.238 SERIAL » 0x010c00130c0591010f260225ea9d (14 bytes) 09:40:14.239 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 234 └─[FibaroVenetianBlindCCGet] payload: 0x0f2602 09:40:14.239 CNTRLR « [Node 033] Endpoint query returned no results, assuming that endpoints are seq uential 09:40:14.239 CNTRLR » [Node 033] querying capabilities for endpoint #1... 09:40:14.242 SERIAL « [ACK] (0x06) 09:40:14.247 SERIAL « 0x0104011301e8 (6 bytes) 09:40:14.247 SERIAL » [ACK] (0x06) 09:40:14.248 DRIVER « [RES] [SendData] was sent: true 09:40:14.311 SERIAL « 0x01070013ea00000607 (9 bytes) 09:40:14.311 SERIAL » [ACK] (0x06) 09:40:14.312 DRIVER « [REQ] [SendData] callback id: 234 transmit status: OK 09:40:14.367 SERIAL « 0x010e0004000c0891010f26030263002a (16 bytes) 09:40:14.369 CNTRLR [Node 012] [Manufacturer Proprietary] fibaro[venetianBlindsPositi [Endpoint 0] on]: metadata updated 09:40:14.369 CNTRLR [Node 012] [~] [Manufacturer Proprietary] fibaro[venetianBlindsPo [Endpoint 0] sition]: 99 => 99 09:40:14.370 SERIAL » [ACK] (0x06) 09:40:14.371 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[FibaroVenetianBlindCCReport] position: 99 09:40:14.374 SERIAL » 0x010a0013210360090125eb62 (12 bytes) 09:40:14.374 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 235 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:40:14.375 CNTRLR « [Node 012] received venetian blind state: position: 99 tilt: undefined 09:40:14.375 CNTRLR [Node 012] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 09:40:14.375 CNTRLR [Node 012] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 09:40:14.407 SERIAL « [ACK] (0x06) 09:40:14.411 SERIAL « 0x0104011301e8 (6 bytes) 09:40:14.411 SERIAL » [ACK] (0x06) 09:40:14.413 DRIVER « [RES] [SendData] was sent: true 09:40:14.415 CNTRLR [Node 012] Interview stage completed: CommandClasses 09:40:14.416 CNTRLR [Node 012] Interview stage completed: OverwriteConfig 09:40:14.416 CNTRLR » [Node 012] requesting node neighbors... 09:40:14.424 SERIAL « 0x010c0004000306310504220549ac (14 bytes) 09:40:14.425 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:40:14.425 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 101.9 => 135.3 [Endpoint 0] 09:40:14.425 SERIAL » [ACK] (0x06) 09:40:14.426 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 135.3 09:40:14.453 SERIAL « 0x010c0004000306310504220549ac (14 bytes) 09:40:14.454 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:40:14.454 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 135.3 => 135.3 [Endpoint 0] 09:40:14.455 SERIAL » [ACK] (0x06) 09:40:14.456 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 135.3 09:40:14.483 SERIAL « 0x01070013eb00000b0b (9 bytes) 09:40:14.484 SERIAL » [ACK] (0x06) 09:40:14.484 DRIVER « [REQ] [SendData] callback id: 235 transmit status: OK 09:40:14.494 SERIAL « 0x010c0004002106600a011101268d (14 bytes) 09:40:14.495 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 1] [internal] 8 09:40:14.495 SERIAL » [ACK] (0x06) 09:40:14.496 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Multilevel Switch specific device class: Multilevel Power Switch is dynamic end point: false supported CCs: · Multilevel Switch 09:40:14.498 SERIAL » 0x010700800c00000074 (9 bytes) 09:40:14.499 DRIVER » [Node 012] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:40:14.499 CNTRLR « [Node 033] received response for endpoint capabilities (#1): generic device class: Multilevel Switch specific device class: Multilevel Power Switch is dynamic end point: false supported CCs: · Multilevel Switch 09:40:14.499 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #2. .. 09:40:14.500 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 2] [internal] 8 09:40:14.500 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #3. .. 09:40:14.500 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 3] [internal] 8 09:40:14.500 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #4. .. 09:40:14.500 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 4] [internal] 8 09:40:14.501 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #5. .. 09:40:14.501 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 5] [internal] 8 09:40:14.501 CNTRLR [Node 033] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:40:14.501 CNTRLR [Node 033] WakeUpCC: doing a complete interview... 09:40:14.502 CNTRLR » [Node 033] retrieving wakeup interval from the device... 09:40:14.505 SERIAL « [ACK] (0x06) 09:40:14.506 SERIAL « 0x0120018065f3bc6b0300000000000000000000000000000000000000000000000 (34 bytes) 01c 09:40:14.506 SERIAL » [ACK] (0x06) 09:40:14.507 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 9, 10, 13, 14, 15, 16, 19, 20, 21, 22, 24, 25, 26, 28, 30, 31, 33, 34 09:40:14.510 SERIAL » 0x010900132102840525ec8e (11 bytes) 09:40:14.510 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 236 └─[WakeUpCCIntervalGet] 09:40:14.511 CNTRLR « [Node 012] node neighbors received: 1, 3, 6, 7, 9, 10, 13, 14, 15, 16, 19, 2 0, 21, 22, 24, 25, 26, 28, 30, 31, 33, 34 09:40:14.511 CNTRLR [Node 012] Interview stage completed: Neighbors 09:40:14.511 CNTRLR [Node 012] Interview completed 09:40:14.513 SERIAL « [ACK] (0x06) 09:40:14.518 SERIAL « 0x0104011301e8 (6 bytes) 09:40:14.518 SERIAL » [ACK] (0x06) 09:40:14.519 DRIVER « [RES] [SendData] was sent: true 09:40:14.535 SERIAL « 0x01070013ec00000205 (9 bytes) 09:40:14.536 SERIAL » [ACK] (0x06) 09:40:14.536 DRIVER « [REQ] [SendData] callback id: 236 transmit status: OK 09:40:16.141 CNTRLR [Node 033] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:40:16.648 SERIAL » 0x010900132102840525ec8e (11 bytes) 09:40:16.649 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 236 └─[WakeUpCCIntervalGet] 09:40:16.652 SERIAL « [ACK] (0x06) 09:40:16.657 SERIAL « 0x0104011301e8 (6 bytes) 09:40:16.658 SERIAL » [ACK] (0x06) 09:40:16.659 DRIVER « [RES] [SendData] was sent: true 09:40:16.675 SERIAL « 0x01070013ec00000205 (9 bytes) 09:40:16.675 SERIAL » [ACK] (0x06) 09:40:16.676 DRIVER « [REQ] [SendData] callback id: 236 transmit status: OK 09:40:18.283 CNTRLR [Node 033] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:40:18.321 SERIAL « 0x010c000400030631050422086b83 (14 bytes) 09:40:18.323 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:40:18.324 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 135.3 => 215.5 [Endpoint 0] 09:40:18.325 SERIAL » [ACK] (0x06) 09:40:18.326 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 215.5 09:40:18.698 SERIAL « 0x010c0004001406310504220000f7 (14 bytes) 09:40:18.699 CNTRLR [Node 020] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:40:18.699 CNTRLR [Node 020] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 09:40:18.700 SERIAL » [ACK] (0x06) 09:40:18.701 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 09:40:18.785 SERIAL » 0x010900132102840525ec8e (11 bytes) 09:40:18.785 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 236 └─[WakeUpCCIntervalGet] 09:40:18.787 SERIAL « [ACK] (0x06) 09:40:18.793 SERIAL « 0x0104011301e8 (6 bytes) 09:40:18.793 SERIAL » [ACK] (0x06) 09:40:18.794 DRIVER « [RES] [SendData] was sent: true 09:40:18.810 SERIAL « 0x01070013ec00000205 (9 bytes) 09:40:18.811 SERIAL » [ACK] (0x06) 09:40:18.811 DRIVER « [REQ] [SendData] callback id: 236 transmit status: OK 09:40:19.322 SERIAL « 0x010c0004000306310504220626c0 (14 bytes) 09:40:19.323 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:40:19.324 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 215.5 => 157.4 [Endpoint 0] 09:40:19.325 SERIAL » [ACK] (0x06) 09:40:19.326 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 157.4 09:40:20.416 SERIAL » 0x010a00131f038e020125edbf (12 bytes) 09:40:20.416 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 237 └─[MultiChannelAssociationCCGet] group id: 1 09:40:20.417 CNTRLR [Node 033] Interview attempt 1/5 failed, retrying in 5000 ms... 09:40:20.418 SERIAL « [ACK] (0x06) 09:40:20.424 SERIAL « 0x0104011301e8 (6 bytes) 09:40:20.425 SERIAL » [ACK] (0x06) 09:40:20.425 DRIVER « [RES] [SendData] was sent: true 09:40:20.442 SERIAL « 0x01070013ed00000204 (9 bytes) 09:40:20.442 SERIAL » [ACK] (0x06) 09:40:20.444 DRIVER « [REQ] [SendData] callback id: 237 transmit status: OK 09:40:20.452 SERIAL « 0x010b0004001f058e0301050063 (13 bytes) 09:40:20.454 SERIAL » [ACK] (0x06) 09:40:20.456 CNTRLR [Node 031] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 09:40:20.458 CNTRLR [Node 031] [~] [Multi Channel Association] nodeIds[1]: => 09:40:20.459 CNTRLR [Node 031] [~] [Multi Channel Association] endpoints[1]: => 09:40:20.461 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: endpoints: 09:40:20.468 SERIAL » 0x010e00131f07600d00012501ff25ee86 (16 bytes) 09:40:20.469 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 238 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCSet] target value: true 09:40:20.470 CNTRLR « [Node 031] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 09:40:20.470 CNTRLR » [Node 031] querying multi channel association group #2... 09:40:20.479 SERIAL « [ACK] (0x06) 09:40:20.481 SERIAL « 0x0104011301e8 (6 bytes) 09:40:20.481 SERIAL » [ACK] (0x06) 09:40:20.482 DRIVER « [RES] [SendData] was sent: true 09:40:20.498 SERIAL « 0x01070013ee00000207 (9 bytes) 09:40:20.498 SERIAL » [ACK] (0x06) 09:40:20.500 DRIVER « [REQ] [SendData] callback id: 238 transmit status: OK 09:40:20.509 SERIAL » 0x010a001303038e020225efa2 (12 bytes) 09:40:20.510 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 239 └─[MultiChannelAssociationCCGet] group id: 2 09:40:20.517 SERIAL « [ACK] (0x06) 09:40:20.520 SERIAL « 0x0104011301e8 (6 bytes) 09:40:20.521 SERIAL » [ACK] (0x06) 09:40:20.524 DRIVER « [RES] [SendData] was sent: true 09:40:20.535 SERIAL « 0x01070013ef00000206 (9 bytes) 09:40:20.535 SERIAL » [ACK] (0x06) 09:40:20.552 DRIVER « [REQ] [SendData] callback id: 239 transmit status: OK 09:40:20.555 SERIAL « 0x010b00040003058e030205007c (13 bytes) 09:40:20.555 SERIAL » [ACK] (0x06) 09:40:20.556 CNTRLR [Node 003] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 09:40:20.557 CNTRLR [Node 003] [~] [Multi Channel Association] nodeIds[2]: => 09:40:20.558 CNTRLR [Node 003] [~] [Multi Channel Association] endpoints[2]: => 09:40:20.559 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 09:40:20.562 SERIAL » 0x010a00131f038e020225f0a1 (12 bytes) 09:40:20.562 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 240 └─[MultiChannelAssociationCCGet] group id: 2 09:40:20.562 CNTRLR « [Node 003] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 09:40:20.563 CNTRLR [Node 003] [~] [Association] hasLifeline: true => true [internal] 09:40:20.563 CNTRLR [Node 003] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 09:40:20.595 SERIAL « [ACK] (0x06) 09:40:20.600 SERIAL « 0x0104011301e8 (6 bytes) 09:40:20.601 SERIAL » [ACK] (0x06) 09:40:20.607 DRIVER « [RES] [SendData] was sent: true 09:40:20.609 SERIAL « 0x01070013f000000219 (9 bytes) 09:40:20.609 SERIAL » [ACK] (0x06) 09:40:20.610 CNTRLR [Node 003] Interview stage completed: CommandClasses 09:40:20.610 CNTRLR [Node 003] Interview stage completed: OverwriteConfig 09:40:20.611 CNTRLR » [Node 003] requesting node neighbors... 09:40:20.613 DRIVER « [REQ] [SendData] callback id: 240 transmit status: OK 09:40:20.619 SERIAL « 0x010b0004001f058e0302050060 (13 bytes) 09:40:20.620 SERIAL » [ACK] (0x06) 09:40:20.622 CNTRLR [Node 031] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 09:40:20.623 CNTRLR [Node 031] [~] [Multi Channel Association] nodeIds[2]: => 09:40:20.624 CNTRLR [Node 031] [~] [Multi Channel Association] endpoints[2]: => 09:40:20.625 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 09:40:20.629 SERIAL » 0x01070080030000007b (9 bytes) 09:40:20.629 DRIVER » [Node 003] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:40:20.629 CNTRLR « [Node 031] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 09:40:20.630 CNTRLR » [Node 031] querying additional non-multi-channel association groups... 09:40:20.630 CNTRLR » [Node 031] querying association group #3... 09:40:20.635 SERIAL « [ACK] (0x06) 09:40:20.636 SERIAL « 0x01200180c1fffd6f0700000000000000000000000000000000000000000000000 (34 bytes) 0f5 09:40:20.637 SERIAL » [ACK] (0x06) 09:40:20.639 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 19, 20, 21, 22, 23, 24 , 25, 26, 27, 28, 30, 31, 33, 34, 35 09:40:20.649 SERIAL » 0x010d00131f06600d0001250225f167 (15 bytes) 09:40:20.649 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 241 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 09:40:20.649 CNTRLR « [Node 003] node neighbors received: 1, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 30, 31, 33, 34, 35 09:40:20.650 CNTRLR [Node 003] Interview stage completed: Neighbors 09:40:20.650 CNTRLR [Node 003] Interview completed 09:40:20.655 SERIAL « [ACK] (0x06) 09:40:20.659 SERIAL « 0x0104011301e8 (6 bytes) 09:40:20.659 SERIAL » [ACK] (0x06) 09:40:20.660 DRIVER « [RES] [SendData] was sent: true 09:40:20.675 SERIAL « 0x01070013f100000218 (9 bytes) 09:40:20.675 SERIAL » [ACK] (0x06) 09:40:20.676 DRIVER « [REQ] [SendData] callback id: 241 transmit status: OK 09:40:20.686 SERIAL « 0x010d0004001f07600d01002503ff5b (15 bytes) 09:40:20.688 CNTRLR [Node 031] [~] [Binary Switch] currentValue: false => true [Endpoint 1] 09:40:20.688 SERIAL » [ACK] (0x06) 09:40:20.689 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: true 09:40:20.692 SERIAL » 0x010a00131f0385020325f2a9 (12 bytes) 09:40:20.693 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 242 └─[AssociationCCGet] group id: 3 09:40:20.695 SERIAL « [ACK] (0x06) 09:40:20.701 SERIAL « 0x0104011301e8 (6 bytes) 09:40:20.701 SERIAL » [ACK] (0x06) 09:40:20.701 DRIVER « [RES] [SendData] was sent: true 09:40:20.718 SERIAL « 0x01070013f20000021b (9 bytes) 09:40:20.718 SERIAL » [ACK] (0x06) 09:40:20.718 DRIVER « [REQ] [SendData] callback id: 242 transmit status: OK 09:40:20.729 SERIAL « 0x010c0004001f068503030100016b (14 bytes) 09:40:20.729 SERIAL » [ACK] (0x06) 09:40:20.730 CNTRLR [Node 031] [~] [Association] maxNodes[3]: 1 => 1 [internal] 09:40:20.730 CNTRLR [Node 031] [~] [Association] nodeIds[3]: 1 => 1 [internal] 09:40:20.731 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 09:40:20.733 SERIAL » 0x010a0013180370053c25f362 (12 bytes) 09:40:20.734 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 243 └─[ConfigurationCCGet] parameter #: 60 09:40:20.734 CNTRLR « [Node 031] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 09:40:20.735 CNTRLR [Node 031] [~] [Association] hasLifeline: true => true [internal] 09:40:20.735 CNTRLR [Node 031] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 09:40:20.735 CNTRLR [Node 031] Interview stage completed: CommandClasses 09:40:20.735 CNTRLR [Node 031] Interview stage completed: OverwriteConfig 09:40:20.735 CNTRLR » [Node 031] requesting node neighbors... 09:40:20.738 SERIAL « [ACK] (0x06) 09:40:20.742 SERIAL « 0x0104011301e8 (6 bytes) 09:40:20.742 SERIAL » [ACK] (0x06) 09:40:20.742 DRIVER « [RES] [SendData] was sent: true 09:40:20.790 SERIAL « 0x01070013f30000031b (9 bytes) 09:40:20.790 SERIAL » [ACK] (0x06) 09:40:20.793 DRIVER « [REQ] [SendData] callback id: 243 transmit status: OK 09:40:20.795 SERIAL « 0x010b000400180570063c0100a6 (13 bytes) 09:40:20.800 CNTRLR [Node 024] [~] [Configuration] 60: 0 => 0 09:40:20.801 SERIAL » [ACK] (0x06) 09:40:20.802 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 1 value: 0 09:40:20.805 SERIAL » 0x010700801f00000067 (9 bytes) 09:40:20.805 DRIVER » [Node 031] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:40:20.806 CNTRLR « [Node 024] parameter #60 has value: 0 09:40:20.806 CNTRLR [Node 024] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 09:40:20.807 CNTRLR [Node 024] ProtectionCC: doing a partial interview... 09:40:20.807 CNTRLR » [Node 024] querying protection status... 09:40:20.811 SERIAL « [ACK] (0x06) 09:40:20.813 SERIAL « 0x012001806579ec0b0700000000000000000000000000000000000000000000000 (34 bytes) 0a2 09:40:20.814 SERIAL » [ACK] (0x06) 09:40:20.814 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 9, 12, 13, 14, 15, 19, 20, 22, 23, 24, 25, 26, 28, 33, 34, 35 09:40:20.819 SERIAL » 0x010900132202600725f473 (11 bytes) 09:40:20.819 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 244 └─[MultiChannelCCEndPointGet] 09:40:20.819 CNTRLR « [Node 031] node neighbors received: 1, 3, 6, 7, 9, 12, 13, 14, 15, 19, 20, 2 2, 23, 24, 25, 26, 28, 33, 34, 35 09:40:20.820 CNTRLR [Node 031] Interview stage completed: Neighbors 09:40:20.820 CNTRLR [Node 031] Interview completed 09:40:20.824 SERIAL « [ACK] (0x06) 09:40:20.827 SERIAL « 0x0104011301e8 (6 bytes) 09:40:20.827 SERIAL » [ACK] (0x06) 09:40:20.828 DRIVER « [RES] [SendData] was sent: true 09:40:20.848 SERIAL « 0x01070013f40000031c (9 bytes) 09:40:20.848 SERIAL » [ACK] (0x06) 09:40:20.849 DRIVER « [REQ] [SendData] callback id: 244 transmit status: OK 09:40:20.862 SERIAL « 0x010b00040022056008400200fd (13 bytes) 09:40:20.863 CNTRLR [Node 034] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:40:20.863 CNTRLR [Node 034] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 09:40:20.863 CNTRLR [Node 034] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:40:20.864 CNTRLR [Node 034] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 09:40:20.864 SERIAL » [ACK] (0x06) 09:40:20.864 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: true endpoint count (aggregated): 0 09:40:20.867 SERIAL » 0x010900132302600725f573 (11 bytes) 09:40:20.868 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 245 └─[MultiChannelCCEndPointGet] 09:40:20.868 CNTRLR [Node 034] The node is alive. 09:40:20.869 CNTRLR [Node 034] The node is ready to be used 09:40:20.870 CNTRLR « [Node 034] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: true endpoint count (aggregated): 0 09:40:20.870 CNTRLR » [Node 034] querying all endpoints... 09:40:20.874 SERIAL « [ACK] (0x06) 09:40:20.879 SERIAL « 0x0104011301e8 (6 bytes) 09:40:20.879 SERIAL » [ACK] (0x06) 09:40:20.880 DRIVER « [RES] [SendData] was sent: true 09:40:22.146 SERIAL « 0x01070013f500007f61 (9 bytes) 09:40:22.147 SERIAL » [ACK] (0x06) 09:40:22.148 DRIVER « [REQ] [SendData] callback id: 245 transmit status: OK 09:40:22.171 SERIAL « 0x010b00040023056008000200bc (13 bytes) 09:40:22.172 CNTRLR [Node 035] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:40:22.173 CNTRLR [Node 035] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 09:40:22.173 CNTRLR [Node 035] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 09:40:22.173 CNTRLR [Node 035] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 09:40:22.173 SERIAL » [ACK] (0x06) 09:40:22.174 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:40:22.178 SERIAL » 0x010900131802750225f65b (11 bytes) 09:40:22.178 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 246 └─[ProtectionCCGet] 09:40:22.179 CNTRLR [Node 035] The node is alive. 09:40:22.179 CNTRLR [Node 035] The node is ready to be used 09:40:22.180 CNTRLR « [Node 035] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 09:40:22.181 CNTRLR » [Node 035] querying all endpoints... 09:40:22.187 SERIAL « [ACK] (0x06) 09:40:22.190 SERIAL « 0x0104011301e8 (6 bytes) 09:40:22.190 SERIAL » [ACK] (0x06) 09:40:22.192 DRIVER « [RES] [SendData] was sent: true 09:40:22.208 SERIAL « 0x01070013f60000021f (9 bytes) 09:40:22.209 SERIAL » [ACK] (0x06) 09:40:22.209 DRIVER « [REQ] [SendData] callback id: 246 transmit status: OK 09:40:22.222 SERIAL « 0x010a0004001804750300009b (12 bytes) 09:40:22.223 CNTRLR [Node 024] [~] [Protection] local: 0 => 0 [Endpoint 0] 09:40:22.223 CNTRLR [Node 024] [~] [Protection] rf: 0 => 0 [Endpoint 0] 09:40:22.224 SERIAL » [ACK] (0x06) 09:40:22.225 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 09:40:22.228 SERIAL » 0x010b00132204600bffff25f778 (13 bytes) 09:40:22.228 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 247 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:40:22.229 CNTRLR « [Node 024] received protection status: local: Unprotected rf Unprotected 09:40:22.229 CNTRLR [Node 024] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 09:40:22.258 SERIAL « [ACK] (0x06) 09:40:22.262 SERIAL « 0x0104011301e8 (6 bytes) 09:40:22.263 SERIAL » [ACK] (0x06) 09:40:22.264 DRIVER « [RES] [SendData] was sent: true 09:40:22.266 SERIAL « 0x01070013f70000031f (9 bytes) 09:40:22.266 SERIAL » [ACK] (0x06) 09:40:22.267 CNTRLR [Node 024] AssociationCC: doing a partial interview... 09:40:22.267 CNTRLR [Node 024] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 09:40:22.267 CNTRLR [Node 024] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:40:22.268 CNTRLR [Node 024] MultiChannelAssociationCC: doing a partial interview... 09:40:22.268 CNTRLR » [Node 024] querying multi channel association group #1... 09:40:22.270 DRIVER « [REQ] [SendData] callback id: 247 transmit status: OK 09:40:22.272 SERIAL « 0x010d0004002207600c00ffff0102bc (15 bytes) 09:40:22.273 SERIAL » [ACK] (0x06) 09:40:22.274 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 09:40:22.276 SERIAL » 0x010a001318038e020125f8ad (12 bytes) 09:40:22.277 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 248 └─[MultiChannelAssociationCCGet] group id: 1 09:40:22.277 CNTRLR « [Node 034] received endpoints: 1, 2 09:40:22.277 CNTRLR » [Node 034] querying capabilities for endpoint #1... 09:40:22.280 SERIAL « [ACK] (0x06) 09:40:22.284 SERIAL « 0x0104011301e8 (6 bytes) 09:40:22.285 SERIAL » [ACK] (0x06) 09:40:22.285 DRIVER « [RES] [SendData] was sent: true 09:40:22.306 SERIAL « 0x01070013f800000310 (9 bytes) 09:40:22.307 SERIAL » [ACK] (0x06) 09:40:22.308 DRIVER « [REQ] [SendData] callback id: 248 transmit status: OK 09:40:23.071 SERIAL « 0x010e00040018088e0301010000010069 (16 bytes) 09:40:23.071 SERIAL » [ACK] (0x06) 09:40:23.074 CNTRLR [Node 024] [~] [Multi Channel Association] maxNodes[1]: 1 => 1 09:40:23.075 CNTRLR [Node 024] [~] [Multi Channel Association] nodeIds[1]: => 09:40:23.076 CNTRLR [Node 024] [~] [Multi Channel Association] endpoints[1]: [object Object] => [o bject Object] 09:40:23.077 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 1 node ids: endpoints: 1:0 09:40:23.080 SERIAL » 0x010b00132304600bffff25f977 (13 bytes) 09:40:23.080 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 249 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:40:23.080 CNTRLR « [Node 024] received information for multi channel association group #1: maximum # of nodes: 1 currently assigned nodes: currently assigned endpoints: 1:0 09:40:23.081 CNTRLR » [Node 024] querying multi channel association group #2... 09:40:23.087 SERIAL « 0x010c00040003063105042203d93a (14 bytes) 09:40:23.088 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:40:23.089 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 157.4 => 98.5 [Endpoint 0] 09:40:23.089 SERIAL » [ACK] (0x06) 09:40:23.089 SERIAL « [CAN] (0x18) 09:40:23.090 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 09:40:23.092 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 98.5 09:40:23.191 SERIAL » 0x010b00132304600bffff25f977 (13 bytes) 09:40:23.191 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 249 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:40:23.194 SERIAL « [ACK] (0x06) 09:40:23.200 SERIAL « 0x0104011301e8 (6 bytes) 09:40:23.201 SERIAL » [ACK] (0x06) 09:40:23.202 DRIVER « [RES] [SendData] was sent: true 09:40:23.322 SERIAL « 0x010c00040003063105042204e400 (14 bytes) 09:40:23.323 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:40:23.324 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 98.5 => 125.2 [Endpoint 0] 09:40:23.324 SERIAL » [ACK] (0x06) 09:40:23.326 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 125.2 09:40:24.511 SERIAL « 0x01070013f900008391 (9 bytes) 09:40:24.511 SERIAL » [ACK] (0x06) 09:40:24.512 DRIVER « [REQ] [SendData] callback id: 249 transmit status: OK 09:40:24.531 SERIAL « 0x010d0004002307600c00ffff0102bd (15 bytes) 09:40:24.531 SERIAL » [ACK] (0x06) 09:40:24.532 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 09:40:24.537 SERIAL » 0x010a001318038e020225faac (12 bytes) 09:40:24.538 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 250 └─[MultiChannelAssociationCCGet] group id: 2 09:40:24.538 CNTRLR « [Node 035] received endpoints: 1, 2 09:40:24.539 CNTRLR » [Node 035] querying capabilities for endpoint #1... 09:40:24.543 SERIAL « [ACK] (0x06) 09:40:24.546 SERIAL « 0x0104011301e8 (6 bytes) 09:40:24.546 SERIAL » [ACK] (0x06) 09:40:24.547 DRIVER « [RES] [SendData] was sent: true 09:40:24.567 SERIAL « 0x01070013fa00000312 (9 bytes) 09:40:24.568 SERIAL » [ACK] (0x06) 09:40:24.568 DRIVER « [REQ] [SendData] callback id: 250 transmit status: OK 09:40:24.581 SERIAL « 0x010b00040018058e0302050067 (13 bytes) 09:40:24.582 SERIAL » [ACK] (0x06) 09:40:24.583 CNTRLR [Node 024] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 09:40:24.584 CNTRLR [Node 024] [~] [Multi Channel Association] nodeIds[2]: => 09:40:24.586 CNTRLR [Node 024] [~] [Multi Channel Association] endpoints[2]: => 09:40:24.587 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 09:40:24.592 SERIAL » 0x010a0013220360090125fb71 (12 bytes) 09:40:24.593 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 251 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:40:24.595 CNTRLR « [Node 024] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 09:40:24.595 CNTRLR » [Node 024] querying multi channel association group #3... 09:40:24.601 SERIAL « [ACK] (0x06) 09:40:24.603 SERIAL « 0x0104011301e8 (6 bytes) 09:40:24.604 SERIAL » [ACK] (0x06) 09:40:24.609 DRIVER « [RES] [SendData] was sent: true 09:40:24.624 SERIAL « 0x01070013fb00000313 (9 bytes) 09:40:24.624 SERIAL » [ACK] (0x06) 09:40:24.625 DRIVER « [REQ] [SendData] callback id: 251 transmit status: OK 09:40:24.640 SERIAL « 0x0114000400220e600a0110015e862585598e32ef26ed (22 bytes) 09:40:24.640 CNTRLR [Node 034] [~] [Multi Channel] commandClasses: 94,134, [Endpoint 1] [internal] 37,133,89,142,50 => 94,134,37,133,89,142,50 09:40:24.641 SERIAL » [ACK] (0x06) 09:40:24.641 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Z-Wave Plus Info · Version · Binary Switch · Association · Association Group Information · Multi Channel Association · Meter 09:40:24.644 SERIAL » 0x010a001318038e020325fcab (12 bytes) 09:40:24.644 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 252 └─[MultiChannelAssociationCCGet] group id: 3 09:40:24.645 CNTRLR « [Node 034] received response for endpoint capabilities (#1): generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Z-Wave Plus Info · Version · Binary Switch · Association · Association Group Information · Multi Channel Association · Meter 09:40:24.645 CNTRLR [Node 034] all endpoints idendical, skipping capability query for endpoint #2. .. 09:40:24.645 CNTRLR [Node 034] [~] [Multi Channel] commandClasses: 94,134, [Endpoint 2] [internal] 37,133,89,142,50 => 94,134,37,133,89,142,50 09:40:24.645 CNTRLR [Node 034] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:40:24.674 SERIAL « [ACK] (0x06) 09:40:24.677 SERIAL « 0x0104011301e8 (6 bytes) 09:40:24.678 SERIAL » [ACK] (0x06) 09:40:24.678 DRIVER « [RES] [SendData] was sent: true 09:40:24.682 CNTRLR [Node 034] ZWavePlusCC: doing a partial interview... [Endpoint 1] 09:40:24.682 CNTRLR [Node 034] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 09:40:24.683 CNTRLR [Node 034] BinarySwitchCC: doing a partial interview... [Endpoint 1] 09:40:24.683 CNTRLR » [Node 034] querying Binary Switch state... [Endpoint 1] 09:40:24.685 SERIAL « 0x01070013fc00000314 (9 bytes) 09:40:24.685 SERIAL » [ACK] (0x06) 09:40:24.686 DRIVER « [REQ] [SendData] callback id: 252 transmit status: OK 09:40:24.688 SERIAL « 0x010b00040018058e0303050066 (13 bytes) 09:40:24.688 SERIAL » [ACK] (0x06) 09:40:24.689 CNTRLR [Node 024] [~] [Multi Channel Association] maxNodes[3]: 5 => 5 09:40:24.690 CNTRLR [Node 024] [~] [Multi Channel Association] nodeIds[3]: => 09:40:24.690 CNTRLR [Node 024] [~] [Multi Channel Association] endpoints[3]: => 09:40:24.691 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 3 maximum # of nodes: 5 node ids: endpoints: 09:40:24.694 SERIAL » 0x010a0013230360090125fd76 (12 bytes) 09:40:24.694 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 253 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:40:24.695 CNTRLR « [Node 024] received information for multi channel association group #3: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 09:40:24.695 CNTRLR » [Node 024] querying multi channel association group #4... 09:40:24.698 SERIAL « [ACK] (0x06) 09:40:24.703 SERIAL « 0x0104011301e8 (6 bytes) 09:40:24.704 SERIAL » [ACK] (0x06) 09:40:24.705 DRIVER « [RES] [SendData] was sent: true 09:40:24.723 SERIAL « 0x01070013fd00000315 (9 bytes) 09:40:24.723 SERIAL » [ACK] (0x06) 09:40:24.724 DRIVER « [REQ] [SendData] callback id: 253 transmit status: OK 09:40:24.747 SERIAL « 0x011a0004002314600a0108065e8e404353989f596c717580818522a3 (28 bytes) 09:40:24.748 CNTRLR [Node 035] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 1] [internal] 64,67,83,152,159,89,108,113,117,128,129,133,34 => 94,142,64,67,83,152,159,89,1 08,113,117,128,129,133,34 09:40:24.748 SERIAL » [ACK] (0x06) 09:40:24.748 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:40:24.751 SERIAL » 0x010a001318038e020425feae (12 bytes) 09:40:24.752 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 254 └─[MultiChannelAssociationCCGet] group id: 4 09:40:24.752 CNTRLR « [Node 035] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 09:40:24.752 CNTRLR » [Node 035] querying capabilities for endpoint #2... 09:40:24.755 SERIAL « [ACK] (0x06) 09:40:24.759 SERIAL « 0x0104011301e8 (6 bytes) 09:40:24.760 SERIAL » [ACK] (0x06) 09:40:24.760 DRIVER « [RES] [SendData] was sent: true 09:40:24.781 SERIAL « 0x01070013fe00000217 (9 bytes) 09:40:24.781 SERIAL » [ACK] (0x06) 09:40:24.781 DRIVER « [REQ] [SendData] callback id: 254 transmit status: OK 09:40:24.794 SERIAL « 0x010b00040018058e0304050061 (13 bytes) 09:40:24.795 SERIAL » [ACK] (0x06) 09:40:24.795 CNTRLR [Node 024] [~] [Multi Channel Association] maxNodes[4]: 5 => 5 09:40:24.799 CNTRLR [Node 024] [~] [Multi Channel Association] nodeIds[4]: => 09:40:24.801 CNTRLR [Node 024] [~] [Multi Channel Association] endpoints[4]: => 09:40:24.802 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 4 maximum # of nodes: 5 node ids: endpoints: 09:40:24.805 SERIAL » 0x010d00132206600d0001250225ff54 (15 bytes) 09:40:24.806 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 255 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 09:40:24.806 CNTRLR « [Node 024] received information for multi channel association group #4: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 09:40:24.806 CNTRLR » [Node 024] querying multi channel association group #5... 09:40:24.818 SERIAL « [ACK] (0x06) 09:40:24.819 SERIAL « 0x0104011301e8 (6 bytes) 09:40:24.820 SERIAL » [ACK] (0x06) 09:40:24.824 DRIVER « [RES] [SendData] was sent: true 09:40:24.863 SERIAL « 0x01070013ff00000317 (9 bytes) 09:40:24.863 SERIAL » [ACK] (0x06) 09:40:24.865 DRIVER « [REQ] [SendData] callback id: 255 transmit status: OK 09:40:24.868 SERIAL « 0x010d0004002207600d010025030099 (15 bytes) 09:40:24.868 CNTRLR [Node 034] [~] [Binary Switch] currentValue: false => false [Endpoint 1] 09:40:24.869 SERIAL » [ACK] (0x06) 09:40:24.870 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: false 09:40:24.874 SERIAL » 0x010a001318038e0205250150 (12 bytes) 09:40:24.874 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 1 └─[MultiChannelAssociationCCGet] group id: 5 09:40:24.875 CNTRLR « [Node 034] received Binary Switch state: [Endpoint 1] current value: false 09:40:24.875 CNTRLR [Node 034] [~] [Binary Switch] interviewComplete: true [Endpoint 1] [internal] => true 09:40:24.876 CNTRLR [Node 034] MeterCC: doing a partial interview... [Endpoint 1] 09:40:24.876 CNTRLR » [Node 034] querying default meter value... [Endpoint 1] 09:40:24.882 SERIAL « [ACK] (0x06) 09:40:24.884 SERIAL « 0x0104011301e8 (6 bytes) 09:40:24.884 SERIAL » [ACK] (0x06) 09:40:24.885 DRIVER « [RES] [SendData] was sent: true 09:40:24.904 SERIAL « 0x0107001301000003e9 (9 bytes) 09:40:24.904 SERIAL » [ACK] (0x06) 09:40:24.904 DRIVER « [REQ] [SendData] callback id: 1 transmit status: OK 09:40:24.917 SERIAL « 0x010b00040018058e0305050060 (13 bytes) 09:40:24.918 SERIAL » [ACK] (0x06) 09:40:24.919 CNTRLR [Node 024] [~] [Multi Channel Association] maxNodes[5]: 5 => 5 09:40:24.919 CNTRLR [Node 024] [~] [Multi Channel Association] nodeIds[5]: => 09:40:24.920 CNTRLR [Node 024] [~] [Multi Channel Association] endpoints[5]: => 09:40:24.921 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 5 maximum # of nodes: 5 node ids: endpoints: 09:40:24.924 SERIAL » 0x010a0013230360090225028a (12 bytes) 09:40:24.924 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 2 └─[MultiChannelCCCapabilityGet] endpoint: 2 09:40:24.925 CNTRLR « [Node 024] received information for multi channel association group #5: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 09:40:24.925 CNTRLR [Node 024] [~] [Association] hasLifeline: true => true [internal] 09:40:24.925 CNTRLR [Node 024] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 09:40:24.926 CNTRLR [Node 024] AssociationGroupInfoCC: doing a partial interview... 09:40:24.926 CNTRLR [Node 024] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 09:40:24.927 CNTRLR [Node 024] CentralSceneCC: doing a partial interview... 09:40:24.928 CNTRLR [Node 024] [~] [Central Scene] interviewComplete: true [Endpoint 0] [internal] => true 09:40:24.928 CNTRLR [Node 024] NotificationCC: doing a partial interview... 09:40:24.928 CNTRLR [Node 024] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 09:40:24.929 CNTRLR [Node 024] Interview stage completed: CommandClasses 09:40:24.929 CNTRLR [Node 024] Interview stage completed: OverwriteConfig 09:40:24.929 CNTRLR » [Node 024] requesting node neighbors... 09:40:24.932 SERIAL « [ACK] (0x06) 09:40:24.934 SERIAL « 0x0104011301e8 (6 bytes) 09:40:24.934 SERIAL » [ACK] (0x06) 09:40:24.936 DRIVER « [RES] [SendData] was sent: true 09:40:24.953 SERIAL « 0x0107001302000003ea (9 bytes) 09:40:24.953 SERIAL » [ACK] (0x06) 09:40:24.954 DRIVER « [REQ] [SendData] callback id: 2 transmit status: OK 09:40:24.976 SERIAL « 0x01160004002310600a0221015e8e31989f596c7180852213 (24 bytes) 09:40:24.976 CNTRLR [Node 035] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 2] [internal] 49,152,159,89,108,113,128,133,34 => 94,142,49,152,159,89,108,113,128,133,34 09:40:24.977 SERIAL » [ACK] (0x06) 09:40:24.977 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:40:24.980 SERIAL » 0x010700801800000060 (9 bytes) 09:40:24.981 DRIVER » [Node 024] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:40:24.981 CNTRLR « [Node 035] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 09:40:24.981 CNTRLR [Node 035] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:40:24.982 CNTRLR [Node 035] BatteryCC: doing a partial interview... 09:40:24.982 CNTRLR » [Node 035] querying battery status... 09:40:24.986 SERIAL « [ACK] (0x06) 09:40:24.990 SERIAL « 0x0120018065f96c6f0700000000000000000000000000000000000000000000000 (34 bytes) 0c6 09:40:24.990 SERIAL » [ACK] (0x06) 09:40:24.991 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 9, 12, 13, 14, 15, 16, 19, 20, 22, 23, 25, 26, 27, 28, 30, 31, 33, 34, 35 09:40:24.995 SERIAL » 0x010d00132206600d000132012503bc (15 bytes) 09:40:24.996 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 3 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[MeterCCGet] 09:40:24.996 CNTRLR « [Node 024] node neighbors received: 1, 3, 6, 7, 9, 12, 13, 14, 15, 16, 19, 2 0, 22, 23, 25, 26, 27, 28, 30, 31, 33, 34, 35 09:40:24.996 CNTRLR [Node 024] Interview stage completed: Neighbors 09:40:24.996 CNTRLR [Node 024] Interview completed 09:40:24.998 SERIAL « [ACK] (0x06) 09:40:25.004 SERIAL « 0x0104011301e8 (6 bytes) 09:40:25.004 SERIAL » [ACK] (0x06) 09:40:25.004 DRIVER « [RES] [SendData] was sent: true 09:40:25.025 SERIAL « 0x0107001303000003eb (9 bytes) 09:40:25.026 SERIAL » [ACK] (0x06) 09:40:25.052 DRIVER « [REQ] [SendData] callback id: 3 transmit status: OK 09:40:25.057 SERIAL « 0x0112000400220c600d010032020144000002419d (20 bytes) 09:40:25.058 CNTRLR [Node 034] [~] [Meter] value[65536]: 5.77 => 5.77 [Endpoint 1] 09:40:25.059 CNTRLR [Node 034] [~] [Meter] deltaTime[65536]: 0 => 0 [Endpoint 1] 09:40:25.059 SERIAL » [ACK] (0x06) 09:40:25.061 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[MeterCCReport] type: Electric scale: kWh rate type: Unspecified value: 5.77 time delta: 0 seconds 09:40:25.064 SERIAL » 0x0109001323028002250467 (11 bytes) 09:40:25.064 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 4 └─[BatteryCCGet] 09:40:25.065 CNTRLR [Node 034] [~] [Meter] interviewComplete: true => true [Endpoint 1] [internal] 09:40:25.066 CNTRLR [Node 034] ZWavePlusCC: doing a partial interview... [Endpoint 2] 09:40:25.067 CNTRLR [Node 034] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 09:40:25.067 CNTRLR [Node 034] BinarySwitchCC: doing a partial interview... [Endpoint 2] 09:40:25.067 CNTRLR » [Node 034] querying Binary Switch state... [Endpoint 2] 09:40:25.071 SERIAL « [ACK] (0x06) 09:40:25.073 SERIAL « 0x0104011301e8 (6 bytes) 09:40:25.073 SERIAL » [ACK] (0x06) 09:40:25.075 DRIVER « [RES] [SendData] was sent: true 09:40:25.093 SERIAL « 0x0107001304000003ec (9 bytes) 09:40:25.093 SERIAL » [ACK] (0x06) 09:40:25.093 DRIVER « [REQ] [SendData] callback id: 4 transmit status: OK 09:40:25.208 SERIAL « 0x0109000400230380036332 (11 bytes) 09:40:25.209 CNTRLR [Node 035] [~] [Battery] level: 99 => 99 [Endpoint 0] 09:40:25.209 CNTRLR [Node 035] [~] [Battery] isLow: false => false [Endpoint 0] 09:40:25.210 SERIAL » [ACK] (0x06) 09:40:25.211 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 99 is low: false 09:40:25.214 SERIAL » 0x010d00132206600d000225022505ad (15 bytes) 09:40:25.214 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 5 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[BinarySwitchCCGet] 09:40:25.215 CNTRLR « [Node 035] received response for battery information: level: 99 09:40:25.215 CNTRLR [Node 035] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:40:25.252 SERIAL « [ACK] (0x06) 09:40:25.253 SERIAL « 0x0104011301e8 (6 bytes) 09:40:25.253 SERIAL » [ACK] (0x06) 09:40:25.254 DRIVER « [RES] [SendData] was sent: true 09:40:25.258 CNTRLR [Node 035] ZWavePlusCC: doing a partial interview... [Endpoint 1] 09:40:25.258 CNTRLR [Node 035] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 09:40:25.259 CNTRLR [Node 035] ThermostatModeCC: doing a partial interview... [Endpoint 1] 09:40:25.259 CNTRLR » [Node 035] querying current thermostat mode... [Endpoint 1] 09:40:25.261 SERIAL « 0x0107001305000003ed (9 bytes) 09:40:25.261 SERIAL » [ACK] (0x06) 09:40:25.262 DRIVER « [REQ] [SendData] callback id: 5 transmit status: OK 09:40:25.264 SERIAL « 0x010d0004002207600d02002503009a (15 bytes) 09:40:25.265 CNTRLR [Node 034] [~] [Binary Switch] currentValue: false => false [Endpoint 2] 09:40:25.265 SERIAL » [ACK] (0x06) 09:40:25.266 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BinarySwitchCCReport] current value: false 09:40:25.269 SERIAL » 0x010d00132306600d000140022506c9 (15 bytes) 09:40:25.270 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 6 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 09:40:25.270 CNTRLR « [Node 034] received Binary Switch state: [Endpoint 2] current value: false 09:40:25.270 CNTRLR [Node 034] [~] [Binary Switch] interviewComplete: true [Endpoint 2] [internal] => true 09:40:25.271 CNTRLR [Node 034] MeterCC: doing a partial interview... [Endpoint 2] 09:40:25.271 CNTRLR » [Node 034] querying default meter value... [Endpoint 2] 09:40:25.274 SERIAL « [ACK] (0x06) 09:40:25.278 SERIAL « 0x0104011301e8 (6 bytes) 09:40:25.278 SERIAL » [ACK] (0x06) 09:40:25.278 DRIVER « [RES] [SendData] was sent: true 09:40:25.301 SERIAL « 0x0107001306000002ef (9 bytes) 09:40:25.301 SERIAL » [ACK] (0x06) 09:40:25.302 DRIVER « [REQ] [SendData] callback id: 6 transmit status: OK 09:40:25.386 SERIAL « 0x010d0004002307600d0100400301fc (15 bytes) 09:40:25.387 CNTRLR [Node 035] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 09:40:25.388 SERIAL » [ACK] (0x06) 09:40:25.389 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 09:40:25.393 SERIAL » 0x010d00132206600d000232012507bb (15 bytes) 09:40:25.394 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 7 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MeterCCGet] 09:40:25.394 CNTRLR « [Node 035] received current thermostat mode: Heat [Endpoint 1] 09:40:25.395 CNTRLR [Node 035] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 1] [internal] ue => true 09:40:25.395 CNTRLR [Node 035] ThermostatSetpointCC: doing a partial interview... [Endpoint 1] 09:40:25.395 CNTRLR » [Node 035] querying current value of setpoint Heating... [Endpoint 1] 09:40:25.400 SERIAL « [ACK] (0x06) 09:40:25.403 SERIAL « 0x0104011301e8 (6 bytes) 09:40:25.403 SERIAL » [ACK] (0x06) 09:40:25.404 DRIVER « [RES] [SendData] was sent: true 09:40:25.417 CNTRLR [Node 033] Beginning interview - last completed stage: RestartFromCache 09:40:25.417 CNTRLR » [Node 033] pinging the node... 09:40:25.424 SERIAL « 0x0107001307000003ef (9 bytes) 09:40:25.424 SERIAL » [ACK] (0x06) 09:40:25.425 DRIVER « [REQ] [SendData] callback id: 7 transmit status: OK 09:40:25.439 SERIAL « 0x0112000400220c600d020032020144000000934e (20 bytes) 09:40:25.441 CNTRLR [Node 034] [~] [Meter] value[65536]: 1.47 => 1.47 [Endpoint 2] 09:40:25.442 CNTRLR [Node 034] [~] [Meter] deltaTime[65536]: 0 => 0 [Endpoint 2] 09:40:25.442 SERIAL » [ACK] (0x06) 09:40:25.444 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: kWh rate type: Unspecified value: 1.47 time delta: 0 seconds 09:40:25.449 SERIAL » 0x010800132101002508e9 (10 bytes) 09:40:25.450 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 8 └─[NoOperationCC] 09:40:25.451 CNTRLR [Node 034] [~] [Meter] interviewComplete: true => true [Endpoint 2] [internal] 09:40:25.510 SERIAL « [ACK] (0x06) 09:40:25.515 SERIAL « 0x0104011301e8 (6 bytes) 09:40:25.516 SERIAL » [ACK] (0x06) 09:40:25.518 DRIVER « [RES] [SendData] was sent: true 09:40:25.522 CNTRLR [Node 034] BinarySwitchCC: doing a partial interview... 09:40:25.522 CNTRLR » [Node 034] querying Binary Switch state... 09:40:25.524 SERIAL « 0x0107001308000002e1 (9 bytes) 09:40:25.525 SERIAL » [ACK] (0x06) 09:40:25.525 DRIVER « [REQ] [SendData] callback id: 8 transmit status: OK 09:40:25.529 SERIAL » 0x010e00132307600d00014302012509c6 (16 bytes) 09:40:25.530 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 9 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:40:25.530 CNTRLR « [Node 033] ping successful 09:40:25.531 CNTRLR [Node 033] ManufacturerSpecificCC: doing a partial interview... 09:40:25.532 CNTRLR [Node 033] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:40:25.532 CNTRLR [Node 033] VersionCC: doing a partial interview... 09:40:25.533 CNTRLR [Node 033] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:40:25.533 CNTRLR [Node 033] trying to load device config 09:40:25.536 SERIAL « [ACK] (0x06) 09:40:25.545 CNTRLR [Node 033] device config loaded 09:40:25.546 CNTRLR » [Node 033] querying device endpoint information... 09:40:25.549 SERIAL « 0x0104011301e8 (6 bytes) 09:40:25.549 SERIAL » [ACK] (0x06) 09:40:25.549 DRIVER « [RES] [SendData] was sent: true 09:40:25.560 SERIAL « 0x0107001309000002e0 (9 bytes) 09:40:25.560 SERIAL » [ACK] (0x06) 09:40:25.560 DRIVER « [REQ] [SendData] callback id: 9 transmit status: OK 09:40:25.651 SERIAL « 0x0110000400230a600d0100430301220118d4 (18 bytes) 09:40:25.652 CNTRLR [Node 035] [~] [Thermostat Setpoint] setpoint[1]: 28 => 28 [Endpoint 1] 09:40:25.653 CNTRLR [Node 035] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 09:40:25.653 SERIAL » [ACK] (0x06) 09:40:25.654 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 28 °C 09:40:25.659 SERIAL » 0x0109001321026007250a8e (11 bytes) 09:40:25.660 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 10 └─[MultiChannelCCEndPointGet] 09:40:25.660 CNTRLR « [Node 035] received current value of setpoint Heating: 28 °C [Endpoint 1] 09:40:25.661 CNTRLR [Node 035] [~] [Thermostat Setpoint] interviewComplete [Endpoint 1] [internal] : true => true 09:40:25.662 CNTRLR [Node 035] NotificationCC: doing a partial interview... [Endpoint 1] 09:40:25.662 CNTRLR [Node 035] [~] [Notification] interviewComplete: true [Endpoint 1] [internal] => true 09:40:25.663 CNTRLR [Node 035] ProtectionCC: doing a partial interview... 09:40:25.663 CNTRLR » [Node 035] querying protection status... 09:40:25.667 SERIAL « [ACK] (0x06) 09:40:25.668 SERIAL « 0x0104011301e8 (6 bytes) 09:40:25.668 SERIAL » [ACK] (0x06) 09:40:25.669 DRIVER « [RES] [SendData] was sent: true 09:40:25.712 SERIAL « 0x010700130a000002e3 (9 bytes) 09:40:25.713 SERIAL » [ACK] (0x06) 09:40:25.717 DRIVER « [REQ] [SendData] callback id: 10 transmit status: OK 09:40:25.720 SERIAL « 0x010a000400210460084005f9 (12 bytes) 09:40:25.721 CNTRLR [Node 033] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:40:25.721 CNTRLR [Node 033] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 09:40:25.721 CNTRLR [Node 033] [~] [Multi Channel] individualCount: 5 => 5 [Endpoint 0] [internal] 09:40:25.722 SERIAL » [ACK] (0x06) 09:40:25.723 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 5 count is dynamic: false identical capabilities: true 09:40:25.732 SERIAL » 0x0109001322022502250bcc (11 bytes) 09:40:25.732 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 11 └─[BinarySwitchCCGet] 09:40:25.733 CNTRLR « [Node 033] received response for device endpoints: endpoint count (individual): 5 count is dynamic: false identical capabilities: true 09:40:25.733 CNTRLR » [Node 033] querying all endpoints... 09:40:25.736 SERIAL « [ACK] (0x06) 09:40:25.740 SERIAL « 0x0104011301e8 (6 bytes) 09:40:25.741 SERIAL » [ACK] (0x06) 09:40:25.741 DRIVER « [RES] [SendData] was sent: true 09:40:25.761 SERIAL « 0x010700130b000002e2 (9 bytes) 09:40:25.762 SERIAL » [ACK] (0x06) 09:40:25.762 DRIVER « [REQ] [SendData] callback id: 11 transmit status: OK 09:40:25.775 SERIAL « 0x01090004002203250300f5 (11 bytes) 09:40:25.775 CNTRLR [Node 034] [~] [Binary Switch] currentValue: false => false [Endpoint 0] 09:40:25.776 SERIAL » [ACK] (0x06) 09:40:25.777 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 09:40:25.780 SERIAL » 0x010b00132104600bffff250c80 (13 bytes) 09:40:25.780 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 12 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:40:25.780 CNTRLR « [Node 034] received Binary Switch state: current value: false 09:40:25.781 CNTRLR [Node 034] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 09:40:25.781 CNTRLR [Node 034] MeterCC: doing a partial interview... 09:40:25.782 CNTRLR » [Node 034] querying meter value (type = Electric, scale = kWh)... 09:40:25.785 SERIAL « [ACK] (0x06) 09:40:25.788 SERIAL « 0x0104011301e8 (6 bytes) 09:40:25.788 SERIAL » [ACK] (0x06) 09:40:25.789 DRIVER « [RES] [SendData] was sent: true 09:40:25.805 SERIAL « 0x010700130c000002e5 (9 bytes) 09:40:25.806 SERIAL » [ACK] (0x06) 09:40:25.807 DRIVER « [REQ] [SendData] callback id: 12 transmit status: OK 09:40:25.816 SERIAL « 0x010c0004002106600c00ffff00bc (14 bytes) 09:40:25.817 SERIAL » [ACK] (0x06) 09:40:25.818 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: # of reports to follow: 0 09:40:25.822 SERIAL » 0x010d00132306600d00017502250df7 (15 bytes) 09:40:25.822 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 13 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 09:40:25.823 CNTRLR « [Node 033] Endpoint query returned no results, assuming that endpoints are seq uential 09:40:25.823 CNTRLR » [Node 033] querying capabilities for endpoint #1... 09:40:25.827 SERIAL « [ACK] (0x06) 09:40:25.831 SERIAL « 0x0104011301e8 (6 bytes) 09:40:25.831 SERIAL » [ACK] (0x06) 09:40:25.831 DRIVER « [RES] [SendData] was sent: true 09:40:25.852 SERIAL « 0x010700130d000003e5 (9 bytes) 09:40:25.853 SERIAL » [ACK] (0x06) 09:40:25.853 DRIVER « [REQ] [SendData] callback id: 13 transmit status: OK 09:40:25.959 SERIAL « 0x010d0004002307600d0100750300c8 (15 bytes) 09:40:25.960 CNTRLR [Node 035] [~] [Protection] local: 0 => 0 [Endpoint 1] 09:40:25.961 SERIAL » [ACK] (0x06) 09:40:25.962 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ProtectionCCReport] local: Unprotected 09:40:25.966 SERIAL » 0x010a00132103600901250e87 (12 bytes) 09:40:25.968 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 14 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:40:25.968 CNTRLR « [Node 035] received protection status: local: Unprotected 09:40:25.968 CNTRLR [Node 035] [~] [Protection] interviewComplete: true => [Endpoint 1] [internal] true 09:40:25.969 CNTRLR [Node 035] BatteryCC: doing a partial interview... [Endpoint 1] 09:40:25.969 CNTRLR » [Node 035] querying battery status... [Endpoint 1] 09:40:25.974 SERIAL « [ACK] (0x06) 09:40:25.980 SERIAL « 0x0104011301e8 (6 bytes) 09:40:25.980 SERIAL » [ACK] (0x06) 09:40:25.980 DRIVER « [RES] [SendData] was sent: true 09:40:25.997 SERIAL « 0x010700130e000002e7 (9 bytes) 09:40:25.997 SERIAL » [ACK] (0x06) 09:40:25.998 DRIVER « [REQ] [SendData] callback id: 14 transmit status: OK 09:40:26.008 SERIAL « 0x010c0004002106600a011101268d (14 bytes) 09:40:26.009 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 1] [internal] 8 09:40:26.009 SERIAL » [ACK] (0x06) 09:40:26.010 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Multilevel Switch specific device class: Multilevel Power Switch is dynamic end point: false supported CCs: · Multilevel Switch 09:40:26.022 SERIAL » 0x010a00132203320100250fde (12 bytes) 09:40:26.023 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 15 └─[MeterCCGet] duration: kWh 09:40:26.023 CNTRLR « [Node 033] received response for endpoint capabilities (#1): generic device class: Multilevel Switch specific device class: Multilevel Power Switch is dynamic end point: false supported CCs: · Multilevel Switch 09:40:26.024 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #2. .. 09:40:26.024 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 2] [internal] 8 09:40:26.024 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #3. .. 09:40:26.025 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 3] [internal] 8 09:40:26.025 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #4. .. 09:40:26.025 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 4] [internal] 8 09:40:26.025 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #5. .. 09:40:26.025 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 5] [internal] 8 09:40:26.026 CNTRLR [Node 033] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:40:26.026 CNTRLR [Node 033] WakeUpCC: doing a complete interview... 09:40:26.026 CNTRLR » [Node 033] retrieving wakeup interval from the device... 09:40:26.031 SERIAL « [ACK] (0x06) 09:40:26.032 SERIAL « 0x0104011301e8 (6 bytes) 09:40:26.033 SERIAL » [ACK] (0x06) 09:40:26.034 DRIVER « [RES] [SendData] was sent: true 09:40:26.052 SERIAL « 0x010700130f000003e7 (9 bytes) 09:40:26.052 SERIAL » [ACK] (0x06) 09:40:26.053 DRIVER « [REQ] [SendData] callback id: 15 transmit status: OK 09:40:26.067 SERIAL « 0x0110000400220a32022144000002410000d5 (18 bytes) 09:40:26.068 CNTRLR [Node 034] [~] [Meter] value[65537]: 5.77 => 5.77 [Endpoint 0] 09:40:26.068 CNTRLR [Node 034] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 09:40:26.069 SERIAL » [ACK] (0x06) 09:40:26.069 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 5.77 time delta: 0 seconds 09:40:26.072 SERIAL » 0x0109001321028405251072 (11 bytes) 09:40:26.073 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[WakeUpCCIntervalGet] 09:40:26.073 CNTRLR » [Node 034] querying meter value (type = Electric, scale = W)... 09:40:26.076 SERIAL « [ACK] (0x06) 09:40:26.080 SERIAL « 0x0104011301e8 (6 bytes) 09:40:26.080 SERIAL » [ACK] (0x06) 09:40:26.081 DRIVER « [RES] [SendData] was sent: true 09:40:26.097 SERIAL « 0x0107001310000002f9 (9 bytes) 09:40:26.097 SERIAL » [ACK] (0x06) 09:40:26.098 DRIVER « [REQ] [SendData] callback id: 16 transmit status: OK 09:40:27.701 CNTRLR [Node 033] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:40:28.181 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:40:28.183 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:40:28.184 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:40:28.185 SERIAL » [ACK] (0x06) 09:40:28.186 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:40:28.207 SERIAL » 0x0109001321028405251072 (11 bytes) 09:40:28.207 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[WakeUpCCIntervalGet] 09:40:28.209 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:40:28.210 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:40:28.211 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:40:28.212 SERIAL » [ACK] (0x06) 09:40:28.215 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:40:28.217 SERIAL « [CAN] (0x18) 09:40:28.218 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 09:40:28.247 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:40:28.248 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:40:28.249 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:40:28.250 SERIAL » [ACK] (0x06) 09:40:28.251 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:40:28.284 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:40:28.285 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:40:28.285 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:40:28.286 SERIAL » [ACK] (0x06) 09:40:28.288 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:40:28.320 SERIAL » 0x0109001321028405251072 (11 bytes) 09:40:28.321 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[WakeUpCCIntervalGet] 09:40:28.324 SERIAL « [ACK] (0x06) 09:40:28.330 SERIAL « 0x0104011301e8 (6 bytes) 09:40:28.331 SERIAL » [ACK] (0x06) 09:40:28.331 DRIVER « [RES] [SendData] was sent: true 09:40:28.347 SERIAL « 0x0107001310000002f9 (9 bytes) 09:40:28.348 SERIAL » [ACK] (0x06) 09:40:28.348 DRIVER « [REQ] [SendData] callback id: 16 transmit status: OK 09:40:28.362 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:40:28.363 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:40:28.364 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:40:28.364 SERIAL » [ACK] (0x06) 09:40:28.366 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:40:28.413 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:40:28.414 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:40:28.415 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:40:28.416 SERIAL » [ACK] (0x06) 09:40:28.417 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:40:28.522 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:40:28.523 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:40:28.524 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:40:28.524 SERIAL » [ACK] (0x06) 09:40:28.525 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:40:28.560 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:40:28.561 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:40:28.562 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:40:28.562 SERIAL » [ACK] (0x06) 09:40:28.563 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:40:28.620 SERIAL « 0x010900040020032001ff0f (11 bytes) 09:40:28.620 SERIAL » [ACK] (0x06) 09:40:28.621 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:40:28.623 CNTRLR [Node 032] treating BasicCC Set as a report 09:40:28.623 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:40:28.628 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:40:28.629 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:40:28.630 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:40:28.630 SERIAL » [ACK] (0x06) 09:40:28.631 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:40:28.687 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:40:28.688 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:40:28.688 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:40:28.688 SERIAL » [ACK] (0x06) 09:40:28.689 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:40:28.763 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:40:28.764 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:40:28.764 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:40:28.765 SERIAL » [ACK] (0x06) 09:40:28.766 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:40:29.323 SERIAL « 0x010c00040003063105042209fa13 (14 bytes) 09:40:29.324 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:40:29.325 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 125.2 => 255.4 [Endpoint 0] 09:40:29.326 SERIAL » [ACK] (0x06) 09:40:29.327 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 255.4 09:40:29.951 CNTRLR [Node 033] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:40:30.455 SERIAL » 0x0109001321028405251072 (11 bytes) 09:40:30.456 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[WakeUpCCIntervalGet] 09:40:30.457 SERIAL « [ACK] (0x06) 09:40:30.464 SERIAL « 0x0104011301e8 (6 bytes) 09:40:30.464 SERIAL » [ACK] (0x06) 09:40:30.465 DRIVER « [RES] [SendData] was sent: true 09:40:30.481 SERIAL « 0x0107001310000002f9 (9 bytes) 09:40:30.481 SERIAL » [ACK] (0x06) 09:40:30.482 DRIVER « [REQ] [SendData] callback id: 16 transmit status: OK 09:40:32.101 SERIAL » 0x010d00132306600d0001800225111e (15 bytes) 09:40:32.102 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 17 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BatteryCCGet] 09:40:32.103 CNTRLR [Node 033] Interview attempt 2/5 failed, retrying in 10000 ms... 09:40:32.104 SERIAL « [ACK] (0x06) 09:40:32.111 SERIAL « 0x0104011301e8 (6 bytes) 09:40:32.111 SERIAL » [ACK] (0x06) 09:40:32.112 DRIVER « [RES] [SendData] was sent: true 09:40:33.426 SERIAL « 0x0112000400180c600d02003202213203c6000074 (20 bytes) 09:40:33.427 CNTRLR [Node 024] [~] [Meter] value[66049]: 122.8 => 96.6 [Endpoint 2] 09:40:33.427 CNTRLR [Node 024] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 2] 09:40:33.428 SERIAL » [ACK] (0x06) 09:40:33.429 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 96.6 time delta: 0 seconds 09:40:33.432 SERIAL « 0x01070013110000847e (9 bytes) 09:40:33.433 SERIAL » [ACK] (0x06) 09:40:33.433 DRIVER « [REQ] [SendData] callback id: 17 transmit status: OK 09:40:33.501 SERIAL « 0x010d0004002307600d01008003635e (15 bytes) 09:40:33.502 CNTRLR [Node 035] [~] [Battery] level: 99 => 99 [Endpoint 1] 09:40:33.503 CNTRLR [Node 035] [~] [Battery] isLow: false => false [Endpoint 1] 09:40:33.503 SERIAL » [ACK] (0x06) 09:40:33.504 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BatteryCCReport] level: 99 is low: false 09:40:33.507 SERIAL » 0x010a001322033201102512d3 (12 bytes) 09:40:33.508 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 18 └─[MeterCCGet] duration: W 09:40:33.508 CNTRLR « [Node 035] received response for battery information: [Endpoint 1] level: 99 09:40:33.508 CNTRLR [Node 035] [~] [Battery] interviewComplete: true => tr [Endpoint 1] [internal] ue 09:40:33.559 SERIAL « [ACK] (0x06) 09:40:33.561 SERIAL « 0x0104011301e8 (6 bytes) 09:40:33.561 SERIAL » [ACK] (0x06) 09:40:33.564 DRIVER « [RES] [SendData] was sent: true 09:40:33.567 CNTRLR [Node 035] ClockCC: doing a partial interview... 09:40:33.568 CNTRLR » [Node 035] requesting current clock setting... 09:40:33.572 SERIAL « 0x0107001312000003fa (9 bytes) 09:40:33.572 SERIAL » [ACK] (0x06) 09:40:33.573 DRIVER « [REQ] [SendData] callback id: 18 transmit status: OK 09:40:33.576 SERIAL « 0x010e00040022083202213200000000fc (16 bytes) 09:40:33.577 CNTRLR [Node 034] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 09:40:33.578 CNTRLR [Node 034] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 09:40:33.578 SERIAL » [ACK] (0x06) 09:40:33.579 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 09:40:33.585 SERIAL » 0x010d00132306600d0001810525131a (15 bytes) 09:40:33.585 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 19 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ClockCCGet] 09:40:33.586 CNTRLR [Node 034] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 09:40:33.587 CNTRLR [Node 034] ConfigurationCC: Loading configuration parameters from device confi g 09:40:33.598 CNTRLR [Node 034] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:40:33.599 CNTRLR [Node 034] [Configuration] 9: metadata updated 09:40:33.601 CNTRLR [Node 034] [Configuration] 10: metadata updated 09:40:33.603 CNTRLR [Node 034] [Configuration] 11: metadata updated 09:40:33.605 CNTRLR [Node 034] [Configuration] 12: metadata updated 09:40:33.606 CNTRLR [Node 034] [Configuration] 13: metadata updated 09:40:33.608 CNTRLR [Node 034] [Configuration] 15: metadata updated 09:40:33.610 CNTRLR [Node 034] [Configuration] 16: metadata updated 09:40:33.611 CNTRLR [Node 034] [Configuration] 17: metadata updated 09:40:33.613 CNTRLR [Node 034] [Configuration] 18: metadata updated 09:40:33.615 CNTRLR [Node 034] [Configuration] 20: metadata updated 09:40:33.617 CNTRLR [Node 034] [Configuration] 21: metadata updated 09:40:33.618 CNTRLR [Node 034] [Configuration] 27: metadata updated 09:40:33.620 CNTRLR [Node 034] [Configuration] 28: metadata updated 09:40:33.622 CNTRLR [Node 034] [Configuration] 29: metadata updated 09:40:33.624 CNTRLR [Node 034] [Configuration] 30: metadata updated 09:40:33.625 CNTRLR [Node 034] [Configuration] 31: metadata updated 09:40:33.626 CNTRLR [Node 034] [Configuration] 32: metadata updated 09:40:33.627 CNTRLR [Node 034] [Configuration] 33: metadata updated 09:40:33.628 CNTRLR [Node 034] [Configuration] 35: metadata updated 09:40:33.629 CNTRLR [Node 034] [Configuration] 36: metadata updated 09:40:33.630 CNTRLR [Node 034] [Configuration] 37: metadata updated 09:40:33.631 CNTRLR [Node 034] [Configuration] 38: metadata updated 09:40:33.632 CNTRLR [Node 034] [Configuration] 40: metadata updated 09:40:33.634 CNTRLR [Node 034] [Configuration] 41: metadata updated 09:40:33.636 CNTRLR [Node 034] [Configuration] 42: metadata updated 09:40:33.637 CNTRLR [Node 034] [Configuration] 43: metadata updated 09:40:33.638 CNTRLR [Node 034] [Configuration] 44: metadata updated 09:40:33.639 CNTRLR [Node 034] [Configuration] 50: metadata updated 09:40:33.640 CNTRLR [Node 034] [Configuration] 51: metadata updated 09:40:33.641 CNTRLR [Node 034] [Configuration] 53: metadata updated 09:40:33.642 CNTRLR [Node 034] [Configuration] 54: metadata updated 09:40:33.643 CNTRLR [Node 034] [Configuration] 55: metadata updated 09:40:33.644 CNTRLR [Node 034] [Configuration] 57: metadata updated 09:40:33.645 CNTRLR [Node 034] [Configuration] 58: metadata updated 09:40:33.646 CNTRLR [Node 034] [Configuration] 59: metadata updated 09:40:33.647 CNTRLR [Node 034] [Configuration] 60: metadata updated 09:40:33.648 CNTRLR [Node 034] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:40:33.648 CNTRLR » [Node 034] querying parameter #9 value... 09:40:33.655 SERIAL « [ACK] (0x06) 09:40:33.656 SERIAL « 0x0104011301e8 (6 bytes) 09:40:33.656 SERIAL » [ACK] (0x06) 09:40:33.668 DRIVER « [RES] [SendData] was sent: true 09:40:33.680 SERIAL « 0x0107001313000003fb (9 bytes) 09:40:33.680 SERIAL » [ACK] (0x06) 09:40:33.682 DRIVER « [REQ] [SendData] callback id: 19 transmit status: OK 09:40:33.702 SERIAL « 0x010e0004002308600d01008106e924f8 (16 bytes) 09:40:33.703 SERIAL » [ACK] (0x06) 09:40:33.704 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ClockCCReport] clock setting: Sunday, 09:36 09:40:33.709 SERIAL » 0x010a0013220370050925148a (12 bytes) 09:40:33.709 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 20 └─[ConfigurationCCGet] parameter #: 9 09:40:33.710 CNTRLR « [Node 035] received current clock setting: Sunday, 09:36 09:40:33.710 CNTRLR [Node 035] [~] [Clock] interviewComplete: true => true [Endpoint 1] [internal] 09:40:33.712 CNTRLR [Node 035] ZWavePlusCC: doing a partial interview... [Endpoint 2] 09:40:33.713 CNTRLR [Node 035] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 09:40:33.713 CNTRLR [Node 035] MultilevelSensorCC: doing a partial interview... [Endpoint 2] 09:40:33.714 CNTRLR » [Node 035] querying Air temperature sensor reading... [Endpoint 2] 09:40:33.721 SERIAL « [ACK] (0x06) 09:40:33.722 SERIAL « 0x0104011301e8 (6 bytes) 09:40:33.722 SERIAL » [ACK] (0x06) 09:40:33.723 DRIVER « [RES] [SendData] was sent: true 09:40:33.768 SERIAL « 0x0107001314000002fd (9 bytes) 09:40:33.768 SERIAL » [ACK] (0x06) 09:40:33.771 DRIVER « [REQ] [SendData] callback id: 20 transmit status: OK 09:40:33.774 SERIAL « 0x010b00040022057006090101a8 (13 bytes) 09:40:33.779 CNTRLR [Node 034] [~] [Configuration] 9: 1 => 1 09:40:33.780 SERIAL » [ACK] (0x06) 09:40:33.780 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 1 value: 1 09:40:33.784 SERIAL » 0x010f00132308600d0002310401002515a3 (17 bytes) 09:40:33.784 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 21 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:40:33.784 CNTRLR « [Node 034] parameter #9 has value: 1 09:40:33.784 CNTRLR » [Node 034] querying parameter #10 value... 09:40:33.788 SERIAL « [ACK] (0x06) 09:40:33.792 SERIAL « 0x0104011301e8 (6 bytes) 09:40:33.793 SERIAL » [ACK] (0x06) 09:40:33.793 DRIVER « [RES] [SendData] was sent: true 09:40:33.814 SERIAL « 0x0107001315000003fd (9 bytes) 09:40:33.814 SERIAL » [ACK] (0x06) 09:40:33.815 DRIVER « [REQ] [SendData] callback id: 21 transmit status: OK 09:40:33.907 SERIAL « 0x0110000400230a600d02003105012200bd07 (18 bytes) 09:40:33.908 CNTRLR [Node 035] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:40:33.908 CNTRLR [Node 035] [~] [Multilevel Sensor] Air temperature: 18.8 => 18.9 [Endpoint 2] 09:40:33.908 SERIAL » [ACK] (0x06) 09:40:33.909 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.9 09:40:33.912 SERIAL » 0x010a0013220370050a25168b (12 bytes) 09:40:33.913 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 22 └─[ConfigurationCCGet] parameter #: 10 09:40:33.913 CNTRLR « [Node 035] received current Air temperature sensor reading: 18.9 [Endpoint 2] °C 09:40:33.913 CNTRLR [Node 035] [~] [Multilevel Sensor] interviewComplete: [Endpoint 2] [internal] true => true 09:40:33.914 CNTRLR [Node 035] NotificationCC: doing a partial interview... [Endpoint 2] 09:40:33.914 CNTRLR [Node 035] [~] [Notification] interviewComplete: true [Endpoint 2] [internal] => true 09:40:33.914 CNTRLR [Node 035] BatteryCC: doing a partial interview... [Endpoint 2] 09:40:33.915 CNTRLR » [Node 035] querying battery status... [Endpoint 2] 09:40:33.918 SERIAL « [ACK] (0x06) 09:40:33.921 SERIAL « 0x0104011301e8 (6 bytes) 09:40:33.921 SERIAL » [ACK] (0x06) 09:40:33.922 DRIVER « [RES] [SendData] was sent: true 09:40:33.941 SERIAL « 0x0107001316000002ff (9 bytes) 09:40:33.942 SERIAL » [ACK] (0x06) 09:40:33.942 DRIVER « [REQ] [SendData] callback id: 22 transmit status: OK 09:40:33.955 SERIAL « 0x010b000400220570060a0100aa (13 bytes) 09:40:33.960 CNTRLR [Node 034] [~] [Configuration] 10: 0 => 0 09:40:33.961 SERIAL » [ACK] (0x06) 09:40:33.962 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 0 09:40:33.965 SERIAL » 0x010d00132306600d0002800225171b (15 bytes) 09:40:33.965 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 23 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[BatteryCCGet] 09:40:33.965 CNTRLR « [Node 034] parameter #10 has value: 0 09:40:33.966 CNTRLR » [Node 034] querying parameter #11 value... 09:40:33.969 SERIAL « [ACK] (0x06) 09:40:33.974 SERIAL « 0x0104011301e8 (6 bytes) 09:40:33.974 SERIAL » [ACK] (0x06) 09:40:33.976 DRIVER « [RES] [SendData] was sent: true 09:40:33.994 SERIAL « 0x0107001317000003ff (9 bytes) 09:40:33.995 SERIAL » [ACK] (0x06) 09:40:33.995 DRIVER « [REQ] [SendData] callback id: 23 transmit status: OK 09:40:34.098 SERIAL « 0x01090004000803300300ca (11 bytes) 09:40:34.099 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:40:34.099 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:40:34.100 SERIAL » [ACK] (0x06) 09:40:34.101 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:40:34.126 SERIAL « 0x010d0004002307600d02008003546a (15 bytes) 09:40:34.127 CNTRLR [Node 035] [~] [Battery] level: 84 => 84 [Endpoint 2] 09:40:34.128 CNTRLR [Node 035] [~] [Battery] isLow: false => false [Endpoint 2] 09:40:34.129 SERIAL » [ACK] (0x06) 09:40:34.133 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BatteryCCReport] level: 84 is low: false 09:40:34.138 SERIAL » 0x010a0013220370050b251884 (12 bytes) 09:40:34.139 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 24 └─[ConfigurationCCGet] parameter #: 11 09:40:34.139 CNTRLR « [Node 035] received response for battery information: [Endpoint 2] level: 84 09:40:34.139 CNTRLR [Node 035] [~] [Battery] interviewComplete: true => tr [Endpoint 2] [internal] ue 09:40:34.140 CNTRLR [Node 035] MultilevelSensorCC: doing a partial interview... 09:40:34.140 CNTRLR » [Node 035] querying Air temperature sensor reading... 09:40:34.153 SERIAL « [ACK] (0x06) 09:40:34.155 SERIAL « 0x0104011301e8 (6 bytes) 09:40:34.155 SERIAL » [ACK] (0x06) 09:40:34.156 DRIVER « [RES] [SendData] was sent: true 09:40:34.158 SERIAL « 0x010d0004002307600d02008003546a (15 bytes) 09:40:34.159 CNTRLR [Node 035] [~] [Battery] level: 84 => 84 [Endpoint 2] 09:40:34.159 CNTRLR [Node 035] [~] [Battery] isLow: false => false [Endpoint 2] 09:40:34.159 SERIAL » [ACK] (0x06) 09:40:34.161 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BatteryCCReport] level: 84 is low: false 09:40:34.182 SERIAL « 0x0107001318000003f0 (9 bytes) 09:40:34.182 SERIAL » [ACK] (0x06) 09:40:34.183 DRIVER « [REQ] [SendData] callback id: 24 transmit status: OK 09:40:34.190 SERIAL « 0x010b000400220570060b0100ab (13 bytes) 09:40:34.196 CNTRLR [Node 034] [~] [Configuration] 11: 0 => 0 09:40:34.197 SERIAL » [ACK] (0x06) 09:40:34.197 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 11 value size: 1 value: 0 09:40:34.201 SERIAL » 0x010b00132304310401002519c8 (13 bytes) 09:40:34.201 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 25 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:40:34.201 CNTRLR « [Node 034] parameter #11 has value: 0 09:40:34.202 CNTRLR » [Node 034] querying parameter #12 value... 09:40:34.205 SERIAL « [ACK] (0x06) 09:40:34.211 SERIAL « 0x0104011301e8 (6 bytes) 09:40:34.212 SERIAL » [ACK] (0x06) 09:40:34.212 DRIVER « [RES] [SendData] was sent: true 09:40:34.230 SERIAL « 0x0107001319000002f0 (9 bytes) 09:40:34.230 SERIAL » [ACK] (0x06) 09:40:34.230 DRIVER « [REQ] [SendData] callback id: 25 transmit status: OK 09:40:34.320 SERIAL « 0x010c00040023063105012200bd78 (14 bytes) 09:40:34.321 CNTRLR [Node 035] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 09:40:34.321 CNTRLR [Node 035] [~] [Multilevel Sensor] Air temperature: 17.4 => 18.9 [Endpoint 0] 09:40:34.321 SERIAL » [ACK] (0x06) 09:40:34.322 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.9 09:40:34.325 SERIAL » 0x010a0013220370050c251a81 (12 bytes) 09:40:34.325 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 26 └─[ConfigurationCCGet] parameter #: 12 09:40:34.326 CNTRLR « [Node 035] received current Air temperature sensor reading: 18.9 °C 09:40:34.326 CNTRLR [Node 035] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 09:40:34.326 CNTRLR [Node 035] ThermostatModeCC: doing a partial interview... 09:40:34.326 CNTRLR » [Node 035] querying current thermostat mode... 09:40:34.329 SERIAL « [ACK] (0x06) 09:40:34.333 SERIAL « 0x0104011301e8 (6 bytes) 09:40:34.333 SERIAL » [ACK] (0x06) 09:40:34.334 DRIVER « [RES] [SendData] was sent: true 09:40:34.354 SERIAL « 0x010700131a000003f2 (9 bytes) 09:40:34.355 SERIAL » [ACK] (0x06) 09:40:34.355 DRIVER « [REQ] [SendData] callback id: 26 transmit status: OK 09:40:34.368 SERIAL « 0x010c000400220670060c02003299 (14 bytes) 09:40:34.376 CNTRLR [Node 034] [~] [Configuration] 12: 50 => 50 09:40:34.377 SERIAL » [ACK] (0x06) 09:40:34.378 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 50 09:40:34.382 SERIAL » 0x0109001323024002251bb8 (11 bytes) 09:40:34.382 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 27 └─[ThermostatModeCCGet] 09:40:34.382 CNTRLR « [Node 034] parameter #12 has value: 50 09:40:34.383 CNTRLR » [Node 034] querying parameter #13 value... 09:40:34.387 SERIAL « [ACK] (0x06) 09:40:34.390 SERIAL « 0x0104011301e8 (6 bytes) 09:40:34.390 SERIAL » [ACK] (0x06) 09:40:34.392 DRIVER « [RES] [SendData] was sent: true 09:40:34.411 SERIAL « 0x010700131b000002f2 (9 bytes) 09:40:34.411 SERIAL » [ACK] (0x06) 09:40:34.412 DRIVER « [REQ] [SendData] callback id: 27 transmit status: OK 09:40:34.517 SERIAL « 0x01090004000803200100d8 (11 bytes) 09:40:34.518 SERIAL » [ACK] (0x06) 09:40:34.522 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:40:34.524 CNTRLR [Node 008] treating BasicCC Set as a report 09:40:34.524 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:40:34.551 SERIAL « 0x0109000400230340030190 (11 bytes) 09:40:34.552 CNTRLR [Node 035] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 0] 09:40:34.552 SERIAL » [ACK] (0x06) 09:40:34.553 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[ThermostatModeCCReport] mode: Heat 09:40:34.556 SERIAL » 0x010a0013220370050d251c86 (12 bytes) 09:40:34.556 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 28 └─[ConfigurationCCGet] parameter #: 13 09:40:34.557 CNTRLR « [Node 035] received current thermostat mode: Heat 09:40:34.557 CNTRLR [Node 035] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 0] [internal] ue => true 09:40:34.557 CNTRLR [Node 035] ThermostatSetpointCC: doing a partial interview... 09:40:34.558 CNTRLR » [Node 035] querying current value of setpoint Heating... 09:40:34.560 SERIAL « [ACK] (0x06) 09:40:34.564 SERIAL « 0x0104011301e8 (6 bytes) 09:40:34.564 SERIAL » [ACK] (0x06) 09:40:34.565 DRIVER « [RES] [SendData] was sent: true 09:40:34.585 SERIAL « 0x010700131c000003f4 (9 bytes) 09:40:34.585 SERIAL » [ACK] (0x06) 09:40:34.586 DRIVER « [REQ] [SendData] callback id: 28 transmit status: OK 09:40:34.599 SERIAL « 0x010c000400220670060d020005af (14 bytes) 09:40:34.604 CNTRLR [Node 034] [~] [Configuration] 13: 5 => 5 09:40:34.605 SERIAL » [ACK] (0x06) 09:40:34.606 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 2 value: 5 09:40:34.609 SERIAL » 0x010a00132303430201251dbe (12 bytes) 09:40:34.610 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 29 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:40:34.610 CNTRLR « [Node 034] parameter #13 has value: 5 09:40:34.610 CNTRLR » [Node 034] querying parameter #15 value... 09:40:34.613 SERIAL « [ACK] (0x06) 09:40:34.618 SERIAL « 0x0104011301e8 (6 bytes) 09:40:34.619 SERIAL » [ACK] (0x06) 09:40:34.620 DRIVER « [RES] [SendData] was sent: true 09:40:34.638 SERIAL « 0x010700131d000002f4 (9 bytes) 09:40:34.638 SERIAL » [ACK] (0x06) 09:40:34.639 DRIVER « [REQ] [SendData] callback id: 29 transmit status: OK 09:40:34.739 SERIAL « 0x010c0004002306430301220118a8 (14 bytes) 09:40:34.740 CNTRLR [Node 035] [~] [Thermostat Setpoint] setpoint[1]: 28 => 28 [Endpoint 0] 09:40:34.740 CNTRLR [Node 035] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 09:40:34.741 SERIAL » [ACK] (0x06) 09:40:34.744 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 28 °C 09:40:34.746 SERIAL » 0x010a0013220370050f251e86 (12 bytes) 09:40:34.747 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 30 └─[ConfigurationCCGet] parameter #: 15 09:40:34.747 CNTRLR « [Node 035] received current value of setpoint Heating: 28 °C 09:40:34.747 CNTRLR [Node 035] [~] [Thermostat Setpoint] interviewComplete [Endpoint 0] [internal] : true => true 09:40:34.748 CNTRLR [Node 035] ConfigurationCC: Loading configuration parameters from device confi g 09:40:34.753 CNTRLR [Node 035] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:40:34.754 CNTRLR [Node 035] [Configuration] 1: metadata updated 09:40:34.755 CNTRLR [Node 035] [Configuration] 2: metadata updated 09:40:34.756 CNTRLR [Node 035] [Configuration] 3: metadata updated 09:40:34.757 CNTRLR [Node 035] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:40:34.757 CNTRLR » [Node 035] querying parameter #1 value... 09:40:34.765 SERIAL « [ACK] (0x06) 09:40:34.766 SERIAL « 0x0104011301e8 (6 bytes) 09:40:34.766 SERIAL » [ACK] (0x06) 09:40:34.766 DRIVER « [RES] [SendData] was sent: true 09:40:34.776 SERIAL « 0x010700131e000003f6 (9 bytes) 09:40:34.776 SERIAL » [ACK] (0x06) 09:40:34.782 DRIVER « [REQ] [SendData] callback id: 30 transmit status: OK 09:40:34.790 SERIAL « 0x010b000400220570060f0100af (13 bytes) 09:40:34.795 CNTRLR [Node 034] [~] [Configuration] 15: 0 => 0 09:40:34.797 SERIAL » [ACK] (0x06) 09:40:34.798 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 15 value size: 1 value: 0 09:40:34.800 SERIAL » 0x010a00132303700501251f88 (12 bytes) 09:40:34.801 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 31 └─[ConfigurationCCGet] parameter #: 1 09:40:34.801 CNTRLR « [Node 034] parameter #15 has value: 0 09:40:34.801 CNTRLR » [Node 034] querying parameter #16 value... 09:40:34.804 SERIAL « [ACK] (0x06) 09:40:34.808 SERIAL « 0x0104011301e8 (6 bytes) 09:40:34.809 SERIAL » [ACK] (0x06) 09:40:34.809 DRIVER « [RES] [SendData] was sent: true 09:40:34.830 SERIAL « 0x010700131f000002f6 (9 bytes) 09:40:34.830 SERIAL » [ACK] (0x06) 09:40:34.830 DRIVER « [REQ] [SendData] callback id: 31 transmit status: OK 09:40:34.923 SERIAL « 0x010e000400230870060104000000f05d (16 bytes) 09:40:34.928 CNTRLR [Node 035] [~] [Configuration] 1: 240 => 240 09:40:34.929 SERIAL » [ACK] (0x06) 09:40:34.930 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 4 value: 240 09:40:34.932 SERIAL » 0x010a001322037005102520a7 (12 bytes) 09:40:34.933 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 32 └─[ConfigurationCCGet] parameter #: 16 09:40:34.933 CNTRLR « [Node 035] parameter #1 has value: 240 09:40:34.933 CNTRLR » [Node 035] querying parameter #2 value... 09:40:34.936 SERIAL « [ACK] (0x06) 09:40:34.941 SERIAL « 0x0104011301e8 (6 bytes) 09:40:34.942 SERIAL » [ACK] (0x06) 09:40:34.942 DRIVER « [RES] [SendData] was sent: true 09:40:34.962 SERIAL « 0x0107001320000002c9 (9 bytes) 09:40:34.962 SERIAL » [ACK] (0x06) 09:40:34.963 DRIVER « [REQ] [SendData] callback id: 32 transmit status: OK 09:40:34.975 SERIAL « 0x010b00040022057006100100b0 (13 bytes) 09:40:34.980 CNTRLR [Node 034] [~] [Configuration] 16: 0 => 0 09:40:34.982 SERIAL » [ACK] (0x06) 09:40:34.982 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 0 09:40:34.985 SERIAL » 0x010a001323037005022521b5 (12 bytes) 09:40:34.985 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 33 └─[ConfigurationCCGet] parameter #: 2 09:40:34.986 CNTRLR « [Node 034] parameter #16 has value: 0 09:40:34.986 CNTRLR » [Node 034] querying parameter #17 value... 09:40:34.993 SERIAL « [ACK] (0x06) 09:40:34.997 SERIAL « 0x0104011301e8 (6 bytes) 09:40:34.997 SERIAL » [ACK] (0x06) 09:40:34.999 DRIVER « [RES] [SendData] was sent: true 09:40:35.014 SERIAL « 0x0107001321000003c9 (9 bytes) 09:40:35.014 SERIAL » [ACK] (0x06) 09:40:35.015 DRIVER « [REQ] [SendData] callback id: 33 transmit status: OK 09:40:35.107 SERIAL « 0x010e00040023087006020400000001af (16 bytes) 09:40:35.112 CNTRLR [Node 035] [~] [Configuration] 2: 1 => 1 09:40:35.113 SERIAL » [ACK] (0x06) 09:40:35.114 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 4 value: 1 09:40:35.116 SERIAL » 0x010a001322037005112522a4 (12 bytes) 09:40:35.117 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 34 └─[ConfigurationCCGet] parameter #: 17 09:40:35.117 CNTRLR « [Node 035] parameter #2 has value: 1 09:40:35.117 CNTRLR » [Node 035] querying parameter #3 value... 09:40:35.120 SERIAL « [ACK] (0x06) 09:40:35.128 SERIAL « 0x0104011301e8 (6 bytes) 09:40:35.128 SERIAL » [ACK] (0x06) 09:40:35.129 DRIVER « [RES] [SendData] was sent: true 09:40:35.146 SERIAL « 0x0107001322000003ca (9 bytes) 09:40:35.146 SERIAL » [ACK] (0x06) 09:40:35.147 DRIVER « [REQ] [SendData] callback id: 34 transmit status: OK 09:40:35.160 SERIAL « 0x010c000400220670061102003284 (14 bytes) 09:40:35.165 CNTRLR [Node 034] [~] [Configuration] 17: 50 => 50 09:40:35.166 SERIAL » [ACK] (0x06) 09:40:35.167 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 17 value size: 2 value: 50 09:40:35.170 SERIAL » 0x010a001323037005032523b6 (12 bytes) 09:40:35.170 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 35 └─[ConfigurationCCGet] parameter #: 3 09:40:35.171 CNTRLR « [Node 034] parameter #17 has value: 50 09:40:35.171 CNTRLR » [Node 034] querying parameter #18 value... 09:40:35.176 SERIAL « [ACK] (0x06) 09:40:35.178 SERIAL « 0x0104011301e8 (6 bytes) 09:40:35.180 SERIAL » [ACK] (0x06) 09:40:35.180 DRIVER « [RES] [SendData] was sent: true 09:40:35.199 SERIAL « 0x0107001323000002ca (9 bytes) 09:40:35.199 SERIAL » [ACK] (0x06) 09:40:35.200 DRIVER « [REQ] [SendData] callback id: 35 transmit status: OK 09:40:35.292 SERIAL « 0x010e00040023087006030400000001ae (16 bytes) 09:40:35.300 CNTRLR [Node 035] [~] [Configuration] 3: 1 => 1 09:40:35.301 SERIAL » [ACK] (0x06) 09:40:35.302 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 4 value: 1 09:40:35.307 SERIAL » 0x010a001322037005122524a1 (12 bytes) 09:40:35.308 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 36 └─[ConfigurationCCGet] parameter #: 18 09:40:35.308 CNTRLR « [Node 035] parameter #3 has value: 1 09:40:35.309 CNTRLR [Node 035] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 09:40:35.351 SERIAL « [ACK] (0x06) 09:40:35.358 SERIAL « 0x0104011301e8 (6 bytes) 09:40:35.358 SERIAL » [ACK] (0x06) 09:40:35.360 DRIVER « [RES] [SendData] was sent: true 09:40:35.363 CNTRLR [Node 035] ProtectionCC: doing a partial interview... 09:40:35.363 CNTRLR » [Node 035] querying protection status... 09:40:35.367 SERIAL « 0x0107001324000003cc (9 bytes) 09:40:35.367 SERIAL » [ACK] (0x06) 09:40:35.372 DRIVER « [REQ] [SendData] callback id: 36 transmit status: OK 09:40:35.375 SERIAL « 0x010c0004002206700612020005b0 (14 bytes) 09:40:35.383 CNTRLR [Node 034] [~] [Configuration] 18: 5 => 5 09:40:35.384 SERIAL » [ACK] (0x06) 09:40:35.386 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 18 value size: 2 value: 5 09:40:35.390 SERIAL » 0x01090013230275022525b3 (11 bytes) 09:40:35.391 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 37 └─[ProtectionCCGet] 09:40:35.391 CNTRLR « [Node 034] parameter #18 has value: 5 09:40:35.392 CNTRLR » [Node 034] querying parameter #20 value... 09:40:35.398 SERIAL « [ACK] (0x06) 09:40:35.401 SERIAL « 0x0104011301e8 (6 bytes) 09:40:35.401 SERIAL » [ACK] (0x06) 09:40:35.403 DRIVER « [RES] [SendData] was sent: true 09:40:35.419 SERIAL « 0x0107001325000002cc (9 bytes) 09:40:35.420 SERIAL » [ACK] (0x06) 09:40:35.420 DRIVER « [REQ] [SendData] callback id: 37 transmit status: OK 09:40:35.504 SERIAL « 0x01090004002303750300a4 (11 bytes) 09:40:35.505 CNTRLR [Node 035] [~] [Protection] local: 0 => 0 [Endpoint 0] 09:40:35.505 SERIAL » [ACK] (0x06) 09:40:35.506 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected 09:40:35.519 SERIAL » 0x010a001322037005142526a5 (12 bytes) 09:40:35.520 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 38 └─[ConfigurationCCGet] parameter #: 20 09:40:35.520 CNTRLR « [Node 035] received protection status: local: Unprotected 09:40:35.521 CNTRLR [Node 035] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 09:40:35.559 SERIAL « [ACK] (0x06) 09:40:35.563 SERIAL « 0x0104011301e8 (6 bytes) 09:40:35.564 SERIAL » [ACK] (0x06) 09:40:35.565 DRIVER « [RES] [SendData] was sent: true 09:40:35.568 CNTRLR [Node 035] ClockCC: doing a partial interview... 09:40:35.568 CNTRLR » [Node 035] requesting current clock setting... 09:40:35.571 SERIAL « 0x0107001326000002cf (9 bytes) 09:40:35.571 SERIAL » [ACK] (0x06) 09:40:35.572 DRIVER « [REQ] [SendData] callback id: 38 transmit status: OK 09:40:35.575 SERIAL « 0x010b00040022057006140102b6 (13 bytes) 09:40:35.582 CNTRLR [Node 034] [~] [Configuration] 20: 2 => 2 09:40:35.584 SERIAL » [ACK] (0x06) 09:40:35.585 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 2 09:40:35.589 SERIAL » 0x0109001323028105252742 (11 bytes) 09:40:35.589 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[ClockCCGet] 09:40:35.590 CNTRLR « [Node 034] parameter #20 has value: 2 09:40:35.590 CNTRLR » [Node 034] querying parameter #21 value... 09:40:35.599 SERIAL « [ACK] (0x06) 09:40:35.601 SERIAL « 0x0104011301e8 (6 bytes) 09:40:35.601 SERIAL » [ACK] (0x06) 09:40:35.603 DRIVER « [RES] [SendData] was sent: true 09:40:35.618 SERIAL « 0x0107001327000002ce (9 bytes) 09:40:35.618 SERIAL » [ACK] (0x06) 09:40:35.619 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 09:40:35.704 SERIAL « 0x010a00040023048106e9249c (12 bytes) 09:40:35.704 SERIAL » [ACK] (0x06) 09:40:35.705 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[ClockCCReport] clock setting: Sunday, 09:36 09:40:35.710 SERIAL » 0x010a001322037005152528aa (12 bytes) 09:40:35.710 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 40 └─[ConfigurationCCGet] parameter #: 21 09:40:35.711 CNTRLR « [Node 035] received current clock setting: Sunday, 09:36 09:40:35.711 CNTRLR [Node 035] [~] [Clock] interviewComplete: true => true [Endpoint 0] [internal] 09:40:35.712 CNTRLR [Node 035] AssociationCC: doing a partial interview... 09:40:35.712 CNTRLR [Node 035] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 09:40:35.712 CNTRLR [Node 035] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:40:35.713 CNTRLR [Node 035] MultiChannelAssociationCC: doing a partial interview... 09:40:35.713 CNTRLR » [Node 035] querying multi channel association group #1... 09:40:35.716 SERIAL « [ACK] (0x06) 09:40:35.718 SERIAL « 0x0104011301e8 (6 bytes) 09:40:35.719 SERIAL » [ACK] (0x06) 09:40:35.719 DRIVER « [RES] [SendData] was sent: true 09:40:35.739 SERIAL « 0x0107001328000002c1 (9 bytes) 09:40:35.740 SERIAL » [ACK] (0x06) 09:40:35.740 DRIVER « [REQ] [SendData] callback id: 40 transmit status: OK 09:40:35.753 SERIAL « 0x010b00040022057006150100b5 (13 bytes) 09:40:35.758 CNTRLR [Node 034] [~] [Configuration] 21: 0 => 0 09:40:35.759 SERIAL » [ACK] (0x06) 09:40:35.760 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 21 value size: 1 value: 0 09:40:35.763 SERIAL » 0x010a001323038e0201252947 (12 bytes) 09:40:35.763 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 41 └─[MultiChannelAssociationCCGet] group id: 1 09:40:35.763 CNTRLR « [Node 034] parameter #21 has value: 0 09:40:35.764 CNTRLR » [Node 034] querying parameter #27 value... 09:40:35.766 SERIAL « [ACK] (0x06) 09:40:35.771 SERIAL « 0x0104011301e8 (6 bytes) 09:40:35.771 SERIAL » [ACK] (0x06) 09:40:35.772 DRIVER « [RES] [SendData] was sent: true 09:40:35.791 SERIAL « 0x0107001329000002c0 (9 bytes) 09:40:35.792 SERIAL » [ACK] (0x06) 09:40:35.792 DRIVER « [REQ] [SendData] callback id: 41 transmit status: OK 09:40:35.812 SERIAL « 0x010e00040023088e0301010000010052 (16 bytes) 09:40:35.812 SERIAL » [ACK] (0x06) 09:40:35.813 CNTRLR [Node 035] [~] [Multi Channel Association] maxNodes[1]: 1 => 1 09:40:35.814 CNTRLR [Node 035] [~] [Multi Channel Association] nodeIds[1]: => 09:40:35.815 CNTRLR [Node 035] [~] [Multi Channel Association] endpoints[1]: [object Object] => [o bject Object] 09:40:35.816 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 1 node ids: endpoints: 1:0 09:40:35.819 SERIAL » 0x010a0013220370051b252aa6 (12 bytes) 09:40:35.819 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 42 └─[ConfigurationCCGet] parameter #: 27 09:40:35.819 CNTRLR « [Node 035] received information for multi channel association group #1: maximum # of nodes: 1 currently assigned nodes: currently assigned endpoints: 1:0 09:40:35.820 CNTRLR [Node 035] [~] [Association] hasLifeline: true => true [internal] 09:40:35.820 CNTRLR [Node 035] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 09:40:35.847 SERIAL « [ACK] (0x06) 09:40:35.850 SERIAL « 0x0104011301e8 (6 bytes) 09:40:35.851 SERIAL » [ACK] (0x06) 09:40:35.852 DRIVER « [RES] [SendData] was sent: true 09:40:35.856 CNTRLR [Node 035] AssociationGroupInfoCC: doing a partial interview... 09:40:35.857 CNTRLR [Node 035] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 09:40:35.857 CNTRLR [Node 035] NotificationCC: doing a partial interview... 09:40:35.858 CNTRLR [Node 035] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 09:40:35.858 CNTRLR [Node 035] Interview stage completed: CommandClasses 09:40:35.859 CNTRLR [Node 035] Interview stage completed: OverwriteConfig 09:40:35.859 CNTRLR » [Node 035] requesting node neighbors... 09:40:35.862 SERIAL « 0x010700132a000002c3 (9 bytes) 09:40:35.862 SERIAL » [ACK] (0x06) 09:40:35.864 DRIVER « [REQ] [SendData] callback id: 42 transmit status: OK 09:40:35.868 SERIAL « 0x010b000400220570061b010fb4 (13 bytes) 09:40:35.873 CNTRLR [Node 034] [~] [Configuration] 27: 15 => 15 09:40:35.874 SERIAL » [ACK] (0x06) 09:40:35.875 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 27 value size: 1 value: 15 09:40:35.878 SERIAL » 0x01070080230000005b (9 bytes) 09:40:35.879 DRIVER » [Node 035] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:40:35.879 CNTRLR « [Node 034] parameter #27 has value: 15 09:40:35.880 CNTRLR » [Node 034] querying parameter #28 value... 09:40:35.883 SERIAL « [ACK] (0x06) 09:40:35.884 SERIAL « 0x0120018005f1ec590300000000000000000000000000000000000000000000000 (34 bytes) 01c 09:40:35.885 SERIAL » [ACK] (0x06) 09:40:35.885 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 9, 13, 14, 15, 16, 19, 20, 22, 23, 24, 25, 28, 29, 31, 33, 3 4 09:40:35.889 SERIAL » 0x010a0013220370051c252ba0 (12 bytes) 09:40:35.889 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 43 └─[ConfigurationCCGet] parameter #: 28 09:40:35.890 CNTRLR « [Node 035] node neighbors received: 1, 3, 9, 13, 14, 15, 16, 19, 20, 22, 23, 24, 25, 28, 29, 31, 33, 34 09:40:35.890 CNTRLR [Node 035] Interview stage completed: Neighbors 09:40:35.890 CNTRLR [Node 035] Interview completed 09:40:35.892 SERIAL « [ACK] (0x06) 09:40:35.897 SERIAL « 0x0104011301e8 (6 bytes) 09:40:35.898 SERIAL » [ACK] (0x06) 09:40:35.898 DRIVER « [RES] [SendData] was sent: true 09:40:35.918 SERIAL « 0x010700132b000002c2 (9 bytes) 09:40:35.919 SERIAL » [ACK] (0x06) 09:40:35.919 DRIVER « [REQ] [SendData] callback id: 43 transmit status: OK 09:40:35.932 SERIAL « 0x010b000400220570061c0100bc (13 bytes) 09:40:35.937 CNTRLR [Node 034] [~] [Configuration] 28: 0 => 0 09:40:35.938 SERIAL » [ACK] (0x06) 09:40:35.939 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 28 value size: 1 value: 0 09:40:35.940 CNTRLR « [Node 034] parameter #28 has value: 0 09:40:35.940 CNTRLR » [Node 034] querying parameter #29 value... 09:40:35.944 SERIAL » 0x010a0013220370051d252ca6 (12 bytes) 09:40:35.944 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 44 └─[ConfigurationCCGet] parameter #: 29 09:40:35.946 SERIAL « [ACK] (0x06) 09:40:35.954 SERIAL « 0x0104011301e8 (6 bytes) 09:40:35.955 SERIAL » [ACK] (0x06) 09:40:35.956 DRIVER « [RES] [SendData] was sent: true 09:40:35.973 SERIAL « 0x010700132c000003c4 (9 bytes) 09:40:35.973 SERIAL » [ACK] (0x06) 09:40:35.974 DRIVER « [REQ] [SendData] callback id: 44 transmit status: OK 09:40:36.002 SERIAL « 0x010b000400220570061d0100bd (13 bytes) 09:40:36.010 CNTRLR [Node 034] [~] [Configuration] 29: 0 => 0 09:40:36.011 SERIAL » [ACK] (0x06) 09:40:36.023 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 29 value size: 1 value: 0 09:40:36.024 CNTRLR « [Node 034] parameter #29 has value: 0 09:40:36.024 CNTRLR » [Node 034] querying parameter #30 value... 09:40:36.028 SERIAL » 0x010a0013220370051e252da4 (12 bytes) 09:40:36.029 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 45 └─[ConfigurationCCGet] parameter #: 30 09:40:36.061 SERIAL « [ACK] (0x06) 09:40:36.063 SERIAL « 0x0104011301e8 (6 bytes) 09:40:36.063 SERIAL » [ACK] (0x06) 09:40:36.064 DRIVER « [RES] [SendData] was sent: true 09:40:36.065 SERIAL « 0x010700132d000003c5 (9 bytes) 09:40:36.066 SERIAL » [ACK] (0x06) 09:40:36.066 DRIVER « [REQ] [SendData] callback id: 45 transmit status: OK 09:40:36.072 SERIAL « 0x010b000400220570061e0100be (13 bytes) 09:40:36.077 CNTRLR [Node 034] [~] [Configuration] 30: 0 => 0 09:40:36.078 SERIAL » [ACK] (0x06) 09:40:36.079 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 0 09:40:36.080 CNTRLR « [Node 034] parameter #30 has value: 0 09:40:36.080 CNTRLR » [Node 034] querying parameter #31 value... 09:40:36.084 SERIAL » 0x010a0013220370051f252ea6 (12 bytes) 09:40:36.084 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 46 └─[ConfigurationCCGet] parameter #: 31 09:40:36.087 SERIAL « [ACK] (0x06) 09:40:36.092 SERIAL « 0x0104011301e8 (6 bytes) 09:40:36.092 SERIAL » [ACK] (0x06) 09:40:36.093 DRIVER « [RES] [SendData] was sent: true 09:40:36.113 SERIAL « 0x010700132e000003c6 (9 bytes) 09:40:36.114 SERIAL » [ACK] (0x06) 09:40:36.114 DRIVER « [REQ] [SendData] callback id: 46 transmit status: OK 09:40:36.127 SERIAL « 0x010c000400220670061f0200ff47 (14 bytes) 09:40:36.132 CNTRLR [Node 034] [~] [Configuration] 31: 255 => 255 09:40:36.133 SERIAL » [ACK] (0x06) 09:40:36.134 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 2 value: 255 09:40:36.135 CNTRLR « [Node 034] parameter #31 has value: 255 09:40:36.135 CNTRLR » [Node 034] querying parameter #32 value... 09:40:36.139 SERIAL » 0x010a00132203700520252f98 (12 bytes) 09:40:36.139 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 47 └─[ConfigurationCCGet] parameter #: 32 09:40:36.140 SERIAL « [ACK] (0x06) 09:40:36.147 SERIAL « 0x0104011301e8 (6 bytes) 09:40:36.147 SERIAL » [ACK] (0x06) 09:40:36.148 DRIVER « [RES] [SendData] was sent: true 09:40:36.168 SERIAL « 0x010700132f000003c7 (9 bytes) 09:40:36.168 SERIAL » [ACK] (0x06) 09:40:36.169 DRIVER « [REQ] [SendData] callback id: 47 transmit status: OK 09:40:36.182 SERIAL « 0x010c000400220670062002000087 (14 bytes) 09:40:36.187 CNTRLR [Node 034] [~] [Configuration] 32: 0 => 0 09:40:36.188 SERIAL » [ACK] (0x06) 09:40:36.189 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 2 value: 0 09:40:36.189 CNTRLR « [Node 034] parameter #32 has value: 0 09:40:36.190 CNTRLR » [Node 034] querying parameter #33 value... 09:40:36.195 SERIAL » 0x010a00132203700521253086 (12 bytes) 09:40:36.195 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 48 └─[ConfigurationCCGet] parameter #: 33 09:40:36.197 SERIAL « [ACK] (0x06) 09:40:36.204 SERIAL « 0x0104011301e8 (6 bytes) 09:40:36.204 SERIAL » [ACK] (0x06) 09:40:36.204 DRIVER « [RES] [SendData] was sent: true 09:40:36.225 SERIAL « 0x0107001330000003d8 (9 bytes) 09:40:36.225 SERIAL » [ACK] (0x06) 09:40:36.225 DRIVER « [REQ] [SendData] callback id: 48 transmit status: OK 09:40:36.239 SERIAL « 0x010c0004002206700621020063e5 (14 bytes) 09:40:36.244 CNTRLR [Node 034] [~] [Configuration] 33: 99 => 99 09:40:36.245 SERIAL » [ACK] (0x06) 09:40:36.245 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 2 value: 99 09:40:36.246 CNTRLR « [Node 034] parameter #33 has value: 99 09:40:36.247 CNTRLR » [Node 034] querying parameter #35 value... 09:40:36.250 SERIAL » 0x010a00132203700523253185 (12 bytes) 09:40:36.250 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 49 └─[ConfigurationCCGet] parameter #: 35 09:40:36.252 SERIAL « [ACK] (0x06) 09:40:36.258 SERIAL « 0x0104011301e8 (6 bytes) 09:40:36.258 SERIAL » [ACK] (0x06) 09:40:36.259 DRIVER « [RES] [SendData] was sent: true 09:40:36.279 SERIAL « 0x0107001331000002d8 (9 bytes) 09:40:36.280 SERIAL » [ACK] (0x06) 09:40:36.280 DRIVER « [REQ] [SendData] callback id: 49 transmit status: OK 09:40:36.293 SERIAL « 0x010b0004002205700623010083 (13 bytes) 09:40:36.298 CNTRLR [Node 034] [~] [Configuration] 35: 0 => 0 09:40:36.299 SERIAL » [ACK] (0x06) 09:40:36.300 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 0 09:40:36.301 CNTRLR « [Node 034] parameter #35 has value: 0 09:40:36.301 CNTRLR » [Node 034] querying parameter #36 value... 09:40:36.305 SERIAL » 0x010a00132203700524253281 (12 bytes) 09:40:36.305 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 50 └─[ConfigurationCCGet] parameter #: 36 09:40:36.306 SERIAL « [ACK] (0x06) 09:40:36.314 SERIAL « 0x0104011301e8 (6 bytes) 09:40:36.314 SERIAL » [ACK] (0x06) 09:40:36.315 DRIVER « [RES] [SendData] was sent: true 09:40:36.334 SERIAL « 0x0107001332000003da (9 bytes) 09:40:36.334 SERIAL » [ACK] (0x06) 09:40:36.335 DRIVER « [REQ] [SendData] callback id: 50 transmit status: OK 09:40:36.348 SERIAL « 0x010c00040022067006240200ff7c (14 bytes) 09:40:36.355 CNTRLR [Node 034] [~] [Configuration] 36: 255 => 255 09:40:36.356 SERIAL » [ACK] (0x06) 09:40:36.357 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 36 value size: 2 value: 255 09:40:36.359 CNTRLR « [Node 034] parameter #36 has value: 255 09:40:36.359 CNTRLR » [Node 034] querying parameter #37 value... 09:40:36.364 SERIAL » 0x010a00132203700525253381 (12 bytes) 09:40:36.364 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 51 └─[ConfigurationCCGet] parameter #: 37 09:40:36.366 SERIAL « [ACK] (0x06) 09:40:36.374 SERIAL « 0x0104011301e8 (6 bytes) 09:40:36.374 SERIAL » [ACK] (0x06) 09:40:36.375 DRIVER « [RES] [SendData] was sent: true 09:40:36.393 SERIAL « 0x0107001333000003db (9 bytes) 09:40:36.393 SERIAL » [ACK] (0x06) 09:40:36.394 DRIVER « [REQ] [SendData] callback id: 51 transmit status: OK 09:40:36.407 SERIAL « 0x010c000400220670062502000082 (14 bytes) 09:40:36.415 CNTRLR [Node 034] [~] [Configuration] 37: 0 => 0 09:40:36.416 SERIAL » [ACK] (0x06) 09:40:36.417 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 37 value size: 2 value: 0 09:40:36.418 CNTRLR « [Node 034] parameter #37 has value: 0 09:40:36.418 CNTRLR » [Node 034] querying parameter #38 value... 09:40:36.423 SERIAL » 0x010a00132203700526253485 (12 bytes) 09:40:36.424 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 52 └─[ConfigurationCCGet] parameter #: 38 09:40:36.426 SERIAL « [ACK] (0x06) 09:40:36.432 SERIAL « 0x0104011301e8 (6 bytes) 09:40:36.433 SERIAL » [ACK] (0x06) 09:40:36.433 DRIVER « [RES] [SendData] was sent: true 09:40:36.453 SERIAL « 0x0107001334000003dc (9 bytes) 09:40:36.453 SERIAL » [ACK] (0x06) 09:40:36.453 DRIVER « [REQ] [SendData] callback id: 52 transmit status: OK 09:40:36.466 SERIAL « 0x010c0004002206700626020063e2 (14 bytes) 09:40:36.481 CNTRLR [Node 034] [~] [Configuration] 38: 99 => 99 09:40:36.482 SERIAL » [ACK] (0x06) 09:40:36.482 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 38 value size: 2 value: 99 09:40:36.483 CNTRLR « [Node 034] parameter #38 has value: 99 09:40:36.483 CNTRLR » [Node 034] querying parameter #40 value... 09:40:36.487 SERIAL » 0x010a0013220370052825358a (12 bytes) 09:40:36.487 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 53 └─[ConfigurationCCGet] parameter #: 40 09:40:36.489 SERIAL « [ACK] (0x06) 09:40:36.495 SERIAL « 0x0104011301e8 (6 bytes) 09:40:36.495 SERIAL » [ACK] (0x06) 09:40:36.496 DRIVER « [RES] [SendData] was sent: true 09:40:36.516 SERIAL « 0x0107001335000003dd (9 bytes) 09:40:36.516 SERIAL » [ACK] (0x06) 09:40:36.517 DRIVER « [REQ] [SendData] callback id: 53 transmit status: OK 09:40:36.530 SERIAL « 0x010b000400220570062801038b (13 bytes) 09:40:36.535 CNTRLR [Node 034] [~] [Configuration] 40: 3 => 3 09:40:36.536 SERIAL » [ACK] (0x06) 09:40:36.537 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 3 09:40:36.538 CNTRLR « [Node 034] parameter #40 has value: 3 09:40:36.538 CNTRLR » [Node 034] querying parameter #41 value... 09:40:36.541 SERIAL » 0x010a00132203700529253688 (12 bytes) 09:40:36.542 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 54 └─[ConfigurationCCGet] parameter #: 41 09:40:36.543 SERIAL « [ACK] (0x06) 09:40:36.549 SERIAL « 0x0104011301e8 (6 bytes) 09:40:36.550 SERIAL » [ACK] (0x06) 09:40:36.550 DRIVER « [RES] [SendData] was sent: true 09:40:36.570 SERIAL « 0x0107001336000002df (9 bytes) 09:40:36.571 SERIAL » [ACK] (0x06) 09:40:36.571 DRIVER « [REQ] [SendData] callback id: 54 transmit status: OK 09:40:36.584 SERIAL « 0x010b000400220570062901028b (13 bytes) 09:40:36.589 CNTRLR [Node 034] [~] [Configuration] 41: 2 => 2 09:40:36.590 SERIAL » [ACK] (0x06) 09:40:36.591 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 41 value size: 1 value: 2 09:40:36.592 CNTRLR « [Node 034] parameter #41 has value: 2 09:40:36.592 CNTRLR » [Node 034] querying parameter #42 value... 09:40:36.596 SERIAL » 0x010a0013220370052a25378a (12 bytes) 09:40:36.596 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 55 └─[ConfigurationCCGet] parameter #: 42 09:40:36.597 SERIAL « [ACK] (0x06) 09:40:36.604 SERIAL « 0x0104011301e8 (6 bytes) 09:40:36.604 SERIAL » [ACK] (0x06) 09:40:36.605 DRIVER « [RES] [SendData] was sent: true 09:40:36.625 SERIAL « 0x0107001337000003df (9 bytes) 09:40:36.625 SERIAL » [ACK] (0x06) 09:40:36.626 DRIVER « [REQ] [SendData] callback id: 55 transmit status: OK 09:40:36.639 SERIAL « 0x010b000400220570062a010389 (13 bytes) 09:40:36.644 CNTRLR [Node 034] [~] [Configuration] 42: 3 => 3 09:40:36.645 SERIAL » [ACK] (0x06) 09:40:36.645 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 3 09:40:36.646 CNTRLR « [Node 034] parameter #42 has value: 3 09:40:36.647 CNTRLR » [Node 034] querying parameter #43 value... 09:40:36.650 SERIAL » 0x010a0013220370052b253884 (12 bytes) 09:40:36.650 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 56 └─[ConfigurationCCGet] parameter #: 43 09:40:36.652 SERIAL « [ACK] (0x06) 09:40:36.658 SERIAL « 0x0104011301e8 (6 bytes) 09:40:36.658 SERIAL » [ACK] (0x06) 09:40:36.659 DRIVER « [RES] [SendData] was sent: true 09:40:36.692 SERIAL « 0x0107001338000002d1 (9 bytes) 09:40:36.692 SERIAL » [ACK] (0x06) 09:40:36.693 DRIVER « [REQ] [SendData] callback id: 56 transmit status: OK 09:40:36.695 SERIAL « 0x010b000400220570062b01018a (13 bytes) 09:40:36.701 CNTRLR [Node 034] [~] [Configuration] 43: 1 => 1 09:40:36.702 SERIAL » [ACK] (0x06) 09:40:36.710 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 1 09:40:36.711 CNTRLR « [Node 034] parameter #43 has value: 1 09:40:36.711 CNTRLR » [Node 034] querying parameter #44 value... 09:40:36.715 SERIAL » 0x010a0013220370052c253982 (12 bytes) 09:40:36.715 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 57 └─[ConfigurationCCGet] parameter #: 44 09:40:36.717 SERIAL « [ACK] (0x06) 09:40:36.723 SERIAL « 0x0104011301e8 (6 bytes) 09:40:36.723 SERIAL » [ACK] (0x06) 09:40:36.724 DRIVER « [RES] [SendData] was sent: true 09:40:36.744 SERIAL « 0x0107001339000003d1 (9 bytes) 09:40:36.744 SERIAL » [ACK] (0x06) 09:40:36.745 DRIVER « [REQ] [SendData] callback id: 57 transmit status: OK 09:40:36.758 SERIAL « 0x010c000400220670062c020258d1 (14 bytes) 09:40:36.764 CNTRLR [Node 034] [~] [Configuration] 44: 600 => 600 09:40:36.765 SERIAL » [ACK] (0x06) 09:40:36.766 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 44 value size: 2 value: 600 09:40:36.768 CNTRLR « [Node 034] parameter #44 has value: 600 09:40:36.768 CNTRLR » [Node 034] querying parameter #50 value... 09:40:36.772 SERIAL » 0x010a00132203700532253a9f (12 bytes) 09:40:36.772 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 58 └─[ConfigurationCCGet] parameter #: 50 09:40:36.774 SERIAL « [ACK] (0x06) 09:40:36.780 SERIAL « 0x0104011301e8 (6 bytes) 09:40:36.780 SERIAL » [ACK] (0x06) 09:40:36.780 DRIVER « [RES] [SendData] was sent: true 09:40:36.801 SERIAL « 0x010700133a000002d3 (9 bytes) 09:40:36.801 SERIAL » [ACK] (0x06) 09:40:36.801 DRIVER « [REQ] [SendData] callback id: 58 transmit status: OK 09:40:36.814 SERIAL « 0x010b0004002205700632011486 (13 bytes) 09:40:36.819 CNTRLR [Node 034] [~] [Configuration] 50: 20 => 20 09:40:36.820 SERIAL » [ACK] (0x06) 09:40:36.821 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 20 09:40:36.822 CNTRLR « [Node 034] parameter #50 has value: 20 09:40:36.822 CNTRLR » [Node 034] querying parameter #51 value... 09:40:36.826 SERIAL » 0x010a00132203700533253b9f (12 bytes) 09:40:36.826 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 59 └─[ConfigurationCCGet] parameter #: 51 09:40:36.830 SERIAL « [ACK] (0x06) 09:40:36.835 SERIAL « 0x0104011301e8 (6 bytes) 09:40:36.835 SERIAL » [ACK] (0x06) 09:40:36.836 DRIVER « [RES] [SendData] was sent: true 09:40:36.855 SERIAL « 0x010700133b000003d3 (9 bytes) 09:40:36.855 SERIAL » [ACK] (0x06) 09:40:36.855 DRIVER « [REQ] [SendData] callback id: 59 transmit status: OK 09:40:36.868 SERIAL « 0x010b0004002205700633010a99 (13 bytes) 09:40:36.873 CNTRLR [Node 034] [~] [Configuration] 51: 10 => 10 09:40:36.874 SERIAL » [ACK] (0x06) 09:40:36.875 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 51 value size: 1 value: 10 09:40:36.876 CNTRLR « [Node 034] parameter #51 has value: 10 09:40:36.876 CNTRLR » [Node 034] querying parameter #53 value... 09:40:36.880 SERIAL » 0x010a00132203700535253c9e (12 bytes) 09:40:36.880 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 60 └─[ConfigurationCCGet] parameter #: 53 09:40:36.882 SERIAL « [ACK] (0x06) 09:40:36.888 SERIAL « 0x0104011301e8 (6 bytes) 09:40:36.888 SERIAL » [ACK] (0x06) 09:40:36.888 DRIVER « [RES] [SendData] was sent: true 09:40:36.909 SERIAL « 0x010700133c000002d5 (9 bytes) 09:40:36.912 SERIAL » [ACK] (0x06) 09:40:36.912 DRIVER « [REQ] [SendData] callback id: 60 transmit status: OK 09:40:36.923 SERIAL « 0x010c0004002206700635020064f6 (14 bytes) 09:40:36.932 CNTRLR [Node 034] [~] [Configuration] 53: 100 => 100 09:40:36.933 SERIAL » [ACK] (0x06) 09:40:36.934 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 53 value size: 2 value: 100 09:40:36.935 CNTRLR « [Node 034] parameter #53 has value: 100 09:40:36.935 CNTRLR » [Node 034] querying parameter #54 value... 09:40:36.939 SERIAL » 0x010a00132203700536253d9c (12 bytes) 09:40:36.940 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 61 └─[ConfigurationCCGet] parameter #: 54 09:40:36.942 SERIAL « [ACK] (0x06) 09:40:36.947 SERIAL « 0x0104011301e8 (6 bytes) 09:40:36.948 SERIAL » [ACK] (0x06) 09:40:36.948 DRIVER « [RES] [SendData] was sent: true 09:40:36.969 SERIAL « 0x010700133d000002d4 (9 bytes) 09:40:36.969 SERIAL » [ACK] (0x06) 09:40:36.969 DRIVER « [REQ] [SendData] callback id: 61 transmit status: OK 09:40:36.983 SERIAL « 0x010b0004002205700636011482 (13 bytes) 09:40:36.989 CNTRLR [Node 034] [~] [Configuration] 54: 20 => 20 09:40:36.990 SERIAL » [ACK] (0x06) 09:40:36.991 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 54 value size: 1 value: 20 09:40:36.992 CNTRLR « [Node 034] parameter #54 has value: 20 09:40:36.992 CNTRLR » [Node 034] querying parameter #55 value... 09:40:36.996 SERIAL » 0x010a00132203700537253e9e (12 bytes) 09:40:36.996 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 62 └─[ConfigurationCCGet] parameter #: 55 09:40:36.998 SERIAL « [ACK] (0x06) 09:40:37.004 SERIAL « 0x0104011301e8 (6 bytes) 09:40:37.004 SERIAL » [ACK] (0x06) 09:40:37.004 DRIVER « [RES] [SendData] was sent: true 09:40:37.025 SERIAL « 0x010700133e000003d6 (9 bytes) 09:40:37.025 SERIAL » [ACK] (0x06) 09:40:37.025 DRIVER « [REQ] [SendData] callback id: 62 transmit status: OK 09:40:37.039 SERIAL « 0x010b0004002205700637010a9d (13 bytes) 09:40:37.044 CNTRLR [Node 034] [~] [Configuration] 55: 10 => 10 09:40:37.044 SERIAL » [ACK] (0x06) 09:40:37.045 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 55 value size: 1 value: 10 09:40:37.046 CNTRLR « [Node 034] parameter #55 has value: 10 09:40:37.046 CNTRLR » [Node 034] querying parameter #57 value... 09:40:37.050 SERIAL » 0x010a00132203700539253f91 (12 bytes) 09:40:37.050 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 63 └─[ConfigurationCCGet] parameter #: 57 09:40:37.052 SERIAL « [ACK] (0x06) 09:40:37.059 SERIAL « 0x0104011301e8 (6 bytes) 09:40:37.059 SERIAL » [ACK] (0x06) 09:40:37.060 DRIVER « [RES] [SendData] was sent: true 09:40:37.079 SERIAL « 0x010700133f000002d6 (9 bytes) 09:40:37.079 SERIAL » [ACK] (0x06) 09:40:37.079 DRIVER « [REQ] [SendData] callback id: 63 transmit status: OK 09:40:37.093 SERIAL « 0x010c0004002206700639020064fa (14 bytes) 09:40:37.098 CNTRLR [Node 034] [~] [Configuration] 57: 100 => 100 09:40:37.099 SERIAL » [ACK] (0x06) 09:40:37.099 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 57 value size: 2 value: 100 09:40:37.100 CNTRLR « [Node 034] parameter #57 has value: 100 09:40:37.101 CNTRLR » [Node 034] querying parameter #58 value... 09:40:37.104 SERIAL » 0x010a0013220370053a2540ed (12 bytes) 09:40:37.104 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 64 └─[ConfigurationCCGet] parameter #: 58 09:40:37.107 SERIAL « [ACK] (0x06) 09:40:37.112 SERIAL « 0x0104011301e8 (6 bytes) 09:40:37.113 SERIAL » [ACK] (0x06) 09:40:37.113 DRIVER « [RES] [SendData] was sent: true 09:40:37.133 SERIAL « 0x0107001340000003a8 (9 bytes) 09:40:37.134 SERIAL » [ACK] (0x06) 09:40:37.134 DRIVER « [REQ] [SendData] callback id: 64 transmit status: OK 09:40:37.148 SERIAL « 0x010c000400220670063a020e1083 (14 bytes) 09:40:37.153 CNTRLR [Node 034] [~] [Configuration] 58: 3600 => 3600 09:40:37.153 SERIAL » [ACK] (0x06) 09:40:37.154 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 58 value size: 2 value: 3600 09:40:37.155 CNTRLR « [Node 034] parameter #58 has value: 3600 09:40:37.155 CNTRLR » [Node 034] querying parameter #59 value... 09:40:37.159 SERIAL » 0x010a0013220370053b2541ed (12 bytes) 09:40:37.159 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 65 └─[ConfigurationCCGet] parameter #: 59 09:40:37.162 SERIAL « [ACK] (0x06) 09:40:37.168 SERIAL « 0x0104011301e8 (6 bytes) 09:40:37.169 SERIAL » [ACK] (0x06) 09:40:37.170 DRIVER « [RES] [SendData] was sent: true 09:40:37.188 SERIAL « 0x0107001341000002a8 (9 bytes) 09:40:37.189 SERIAL » [ACK] (0x06) 09:40:37.189 DRIVER « [REQ] [SendData] callback id: 65 transmit status: OK 09:40:37.202 SERIAL « 0x010c000400220670063b020e1082 (14 bytes) 09:40:37.210 CNTRLR [Node 034] [~] [Configuration] 59: 3600 => 3600 09:40:37.211 SERIAL » [ACK] (0x06) 09:40:37.212 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 59 value size: 2 value: 3600 09:40:37.213 CNTRLR « [Node 034] parameter #59 has value: 3600 09:40:37.213 CNTRLR » [Node 034] querying parameter #60 value... 09:40:37.221 SERIAL » 0x010a0013220370053c2542e9 (12 bytes) 09:40:37.222 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 66 └─[ConfigurationCCGet] parameter #: 60 09:40:37.225 SERIAL « [ACK] (0x06) 09:40:37.231 SERIAL « 0x0104011301e8 (6 bytes) 09:40:37.231 SERIAL » [ACK] (0x06) 09:40:37.232 DRIVER « [RES] [SendData] was sent: true 09:40:37.252 SERIAL « 0x0107001342000002ab (9 bytes) 09:40:37.253 SERIAL » [ACK] (0x06) 09:40:37.253 DRIVER « [REQ] [SendData] callback id: 66 transmit status: OK 09:40:37.266 SERIAL « 0x010b000400220570063c01009c (13 bytes) 09:40:37.273 CNTRLR [Node 034] [~] [Configuration] 60: 0 => 0 09:40:37.274 SERIAL » [ACK] (0x06) 09:40:37.275 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 1 value: 0 09:40:37.276 CNTRLR « [Node 034] parameter #60 has value: 0 09:40:37.277 CNTRLR [Node 034] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 09:40:37.326 CNTRLR [Node 034] ProtectionCC: doing a partial interview... 09:40:37.326 CNTRLR » [Node 034] querying protection status... 09:40:37.335 SERIAL » 0x01090013220275022543d4 (11 bytes) 09:40:37.336 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 67 └─[ProtectionCCGet] 09:40:37.338 SERIAL « [ACK] (0x06) 09:40:37.343 SERIAL « 0x0104011301e8 (6 bytes) 09:40:37.344 SERIAL » [ACK] (0x06) 09:40:37.344 DRIVER « [RES] [SendData] was sent: true 09:40:37.365 SERIAL « 0x0107001343000003ab (9 bytes) 09:40:37.365 SERIAL » [ACK] (0x06) 09:40:37.366 DRIVER « [REQ] [SendData] callback id: 67 transmit status: OK 09:40:37.378 SERIAL « 0x010a000400220475030000a1 (12 bytes) 09:40:37.379 CNTRLR [Node 034] [~] [Protection] local: 0 => 0 [Endpoint 0] 09:40:37.380 CNTRLR [Node 034] [~] [Protection] rf: 0 => 0 [Endpoint 0] 09:40:37.380 SERIAL » [ACK] (0x06) 09:40:37.381 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 09:40:37.383 CNTRLR « [Node 034] received protection status: local: Unprotected rf Unprotected 09:40:37.383 CNTRLR [Node 034] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 09:40:37.384 CNTRLR [Node 034] AssociationCC: doing a partial interview... 09:40:37.384 CNTRLR [Node 034] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 09:40:37.384 CNTRLR [Node 034] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:40:37.385 CNTRLR [Node 034] MultiChannelAssociationCC: doing a partial interview... 09:40:37.385 CNTRLR » [Node 034] querying multi channel association group #1... 09:40:37.390 SERIAL » 0x010a001322038e020125442b (12 bytes) 09:40:37.390 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 68 └─[MultiChannelAssociationCCGet] group id: 1 09:40:37.393 SERIAL « [ACK] (0x06) 09:40:37.398 SERIAL « 0x0104011301e8 (6 bytes) 09:40:37.399 SERIAL » [ACK] (0x06) 09:40:37.399 DRIVER « [RES] [SendData] was sent: true 09:40:37.419 SERIAL « 0x0107001344000002ad (9 bytes) 09:40:37.420 SERIAL » [ACK] (0x06) 09:40:37.420 DRIVER « [REQ] [SendData] callback id: 68 transmit status: OK 09:40:37.434 SERIAL « 0x010e00040022088e0301010000010053 (16 bytes) 09:40:37.435 SERIAL » [ACK] (0x06) 09:40:37.436 CNTRLR [Node 034] [~] [Multi Channel Association] maxNodes[1]: 1 => 1 09:40:37.437 CNTRLR [Node 034] [~] [Multi Channel Association] nodeIds[1]: => 09:40:37.438 CNTRLR [Node 034] [~] [Multi Channel Association] endpoints[1]: [object Object] => [o bject Object] 09:40:37.439 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 1 node ids: endpoints: 1:0 09:40:37.440 CNTRLR « [Node 034] received information for multi channel association group #1: maximum # of nodes: 1 currently assigned nodes: currently assigned endpoints: 1:0 09:40:37.441 CNTRLR » [Node 034] querying multi channel association group #2... 09:40:37.446 SERIAL » 0x010a001322038e0202254529 (12 bytes) 09:40:37.446 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 69 └─[MultiChannelAssociationCCGet] group id: 2 09:40:37.448 SERIAL « [ACK] (0x06) 09:40:37.459 SERIAL « 0x0104011301e8 (6 bytes) 09:40:37.460 SERIAL » [ACK] (0x06) 09:40:37.462 DRIVER « [RES] [SendData] was sent: true 09:40:37.475 SERIAL « 0x0107001345000003ad (9 bytes) 09:40:37.475 SERIAL » [ACK] (0x06) 09:40:37.476 DRIVER « [REQ] [SendData] callback id: 69 transmit status: OK 09:40:37.489 SERIAL « 0x010b00040022058e030205005d (13 bytes) 09:40:37.489 SERIAL » [ACK] (0x06) 09:40:37.490 CNTRLR [Node 034] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 09:40:37.491 CNTRLR [Node 034] [~] [Multi Channel Association] nodeIds[2]: => 09:40:37.491 CNTRLR [Node 034] [~] [Multi Channel Association] endpoints[2]: => 09:40:37.492 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 09:40:37.493 CNTRLR « [Node 034] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 09:40:37.493 CNTRLR » [Node 034] querying multi channel association group #3... 09:40:37.497 SERIAL » 0x010a001322038e020325462b (12 bytes) 09:40:37.497 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 70 └─[MultiChannelAssociationCCGet] group id: 3 09:40:37.499 SERIAL « [ACK] (0x06) 09:40:37.506 SERIAL « 0x0104011301e8 (6 bytes) 09:40:37.506 SERIAL » [ACK] (0x06) 09:40:37.507 DRIVER « [RES] [SendData] was sent: true 09:40:37.526 SERIAL « 0x0107001346000003ae (9 bytes) 09:40:37.526 SERIAL » [ACK] (0x06) 09:40:37.527 DRIVER « [REQ] [SendData] callback id: 70 transmit status: OK 09:40:37.564 SERIAL « 0x010b00040022058e030305005c (13 bytes) 09:40:37.565 SERIAL » [ACK] (0x06) 09:40:37.567 CNTRLR [Node 034] [~] [Multi Channel Association] maxNodes[3]: 5 => 5 09:40:37.568 CNTRLR [Node 034] [~] [Multi Channel Association] nodeIds[3]: => 09:40:37.569 CNTRLR [Node 034] [~] [Multi Channel Association] endpoints[3]: => 09:40:37.570 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 3 maximum # of nodes: 5 node ids: endpoints: 09:40:37.571 CNTRLR « [Node 034] received information for multi channel association group #3: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 09:40:37.571 CNTRLR » [Node 034] querying multi channel association group #4... 09:40:37.574 SERIAL » 0x010a001322038e020425472d (12 bytes) 09:40:37.575 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 71 └─[MultiChannelAssociationCCGet] group id: 4 09:40:37.577 SERIAL « [ACK] (0x06) 09:40:37.583 SERIAL « 0x0104011301e8 (6 bytes) 09:40:37.583 SERIAL » [ACK] (0x06) 09:40:37.584 DRIVER « [RES] [SendData] was sent: true 09:40:37.605 SERIAL « 0x0107001347000003af (9 bytes) 09:40:37.605 SERIAL » [ACK] (0x06) 09:40:37.605 DRIVER « [REQ] [SendData] callback id: 71 transmit status: OK 09:40:37.618 SERIAL « 0x010b00040022058e030405005b (13 bytes) 09:40:37.619 SERIAL » [ACK] (0x06) 09:40:37.619 CNTRLR [Node 034] [~] [Multi Channel Association] maxNodes[4]: 5 => 5 09:40:37.620 CNTRLR [Node 034] [~] [Multi Channel Association] nodeIds[4]: => 09:40:37.621 CNTRLR [Node 034] [~] [Multi Channel Association] endpoints[4]: => 09:40:37.622 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 4 maximum # of nodes: 5 node ids: endpoints: 09:40:37.623 CNTRLR « [Node 034] received information for multi channel association group #4: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 09:40:37.623 CNTRLR » [Node 034] querying multi channel association group #5... 09:40:37.627 SERIAL » 0x010a001322038e0205254823 (12 bytes) 09:40:37.627 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 72 └─[MultiChannelAssociationCCGet] group id: 5 09:40:37.629 SERIAL « [ACK] (0x06) 09:40:37.636 SERIAL « 0x0104011301e8 (6 bytes) 09:40:37.637 SERIAL » [ACK] (0x06) 09:40:37.639 DRIVER « [RES] [SendData] was sent: true 09:40:37.656 SERIAL « 0x0107001348000003a0 (9 bytes) 09:40:37.656 SERIAL » [ACK] (0x06) 09:40:37.657 DRIVER « [REQ] [SendData] callback id: 72 transmit status: OK 09:40:37.670 SERIAL « 0x010b00040022058e030505005a (13 bytes) 09:40:37.670 SERIAL » [ACK] (0x06) 09:40:37.671 CNTRLR [Node 034] [~] [Multi Channel Association] maxNodes[5]: 5 => 5 09:40:37.672 CNTRLR [Node 034] [~] [Multi Channel Association] nodeIds[5]: => 09:40:37.674 CNTRLR [Node 034] [~] [Multi Channel Association] endpoints[5]: => 09:40:37.675 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 5 maximum # of nodes: 5 node ids: endpoints: 09:40:37.676 CNTRLR « [Node 034] received information for multi channel association group #5: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 09:40:37.677 CNTRLR [Node 034] [~] [Association] hasLifeline: true => true [internal] 09:40:37.677 CNTRLR [Node 034] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 09:40:37.677 CNTRLR [Node 034] AssociationGroupInfoCC: doing a partial interview... 09:40:37.678 CNTRLR [Node 034] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 09:40:37.678 CNTRLR [Node 034] CentralSceneCC: doing a partial interview... 09:40:37.678 CNTRLR [Node 034] [~] [Central Scene] interviewComplete: true [Endpoint 0] [internal] => true 09:40:37.679 CNTRLR [Node 034] NotificationCC: doing a partial interview... 09:40:37.679 CNTRLR [Node 034] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 09:40:37.679 CNTRLR [Node 034] Interview stage completed: CommandClasses 09:40:37.679 CNTRLR [Node 034] Interview stage completed: OverwriteConfig 09:40:37.679 CNTRLR » [Node 034] requesting node neighbors... 09:40:37.682 SERIAL » 0x01070080220000005a (9 bytes) 09:40:37.683 DRIVER » [Node 034] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:40:37.686 SERIAL « [ACK] (0x06) 09:40:37.687 SERIAL « 0x0120018065f9ac5b0500000000000000000000000000000000000000000000000 (34 bytes) 030 09:40:37.687 SERIAL » [ACK] (0x06) 09:40:37.688 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 9, 12, 13, 14, 15, 16, 19, 20, 22, 24, 25, 26, 28, 29, 31, 33, 35 09:40:37.690 CNTRLR « [Node 034] node neighbors received: 1, 3, 6, 7, 9, 12, 13, 14, 15, 16, 19, 2 0, 22, 24, 25, 26, 28, 29, 31, 33, 35 09:40:37.691 CNTRLR [Node 034] Interview stage completed: Neighbors 09:40:37.691 CNTRLR [Node 034] Interview completed 09:40:37.883 SERIAL « 0x010900040008033003ff35 (11 bytes) 09:40:37.884 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:40:37.884 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:40:37.885 SERIAL » [ACK] (0x06) 09:40:37.886 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:40:37.938 SERIAL « 0x010900040008032001ff27 (11 bytes) 09:40:37.938 SERIAL » [ACK] (0x06) 09:40:37.939 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:40:37.940 CNTRLR [Node 008] treating BasicCC Set as a report 09:40:37.940 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:40:41.866 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 09:40:41.867 SERIAL » [ACK] (0x06) 09:40:41.868 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  09:40:41.870 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 09:40:42.104 CNTRLR [Node 033] Beginning interview - last completed stage: RestartFromCache 09:40:42.105 CNTRLR » [Node 033] pinging the node... 09:40:42.113 SERIAL » 0x010800132101002549a8 (10 bytes) 09:40:42.114 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 73 └─[NoOperationCC] 09:40:42.116 SERIAL « [ACK] (0x06) 09:40:42.122 SERIAL « 0x0104011301e8 (6 bytes) 09:40:42.122 SERIAL » [ACK] (0x06) 09:40:42.123 DRIVER « [RES] [SendData] was sent: true 09:40:42.139 SERIAL « 0x0107001349000002a0 (9 bytes) 09:40:42.139 SERIAL » [ACK] (0x06) 09:40:42.140 DRIVER « [REQ] [SendData] callback id: 73 transmit status: OK 09:40:42.144 CNTRLR « [Node 033] ping successful 09:40:42.147 CNTRLR [Node 033] ManufacturerSpecificCC: doing a partial interview... 09:40:42.148 CNTRLR [Node 033] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:40:42.207 CNTRLR [Node 033] VersionCC: doing a partial interview... 09:40:42.207 CNTRLR [Node 033] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:40:42.208 CNTRLR [Node 033] trying to load device config 09:40:42.216 CNTRLR [Node 033] device config loaded 09:40:42.216 CNTRLR » [Node 033] querying device endpoint information... 09:40:42.220 SERIAL » 0x0109001321026007254ace (11 bytes) 09:40:42.220 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 74 └─[MultiChannelCCEndPointGet] 09:40:42.222 SERIAL « [ACK] (0x06) 09:40:42.228 SERIAL « 0x0104011301e8 (6 bytes) 09:40:42.229 SERIAL » [ACK] (0x06) 09:40:42.229 DRIVER « [RES] [SendData] was sent: true 09:40:42.246 SERIAL « 0x010700134a000002a3 (9 bytes) 09:40:42.246 SERIAL » [ACK] (0x06) 09:40:42.246 DRIVER « [REQ] [SendData] callback id: 74 transmit status: OK 09:40:42.256 SERIAL « 0x010a000400210460084005f9 (12 bytes) 09:40:42.257 CNTRLR [Node 033] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:40:42.257 CNTRLR [Node 033] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 09:40:42.257 CNTRLR [Node 033] [~] [Multi Channel] individualCount: 5 => 5 [Endpoint 0] [internal] 09:40:42.258 SERIAL » [ACK] (0x06) 09:40:42.258 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 5 count is dynamic: false identical capabilities: true 09:40:42.259 CNTRLR « [Node 033] received response for device endpoints: endpoint count (individual): 5 count is dynamic: false identical capabilities: true 09:40:42.259 CNTRLR » [Node 033] querying all endpoints... 09:40:42.274 SERIAL » 0x010b00132104600bffff254bc7 (13 bytes) 09:40:42.274 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 75 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:40:42.276 SERIAL « [ACK] (0x06) 09:40:42.282 SERIAL « 0x0104011301e8 (6 bytes) 09:40:42.283 SERIAL » [ACK] (0x06) 09:40:42.283 DRIVER « [RES] [SendData] was sent: true 09:40:42.300 SERIAL « 0x010700134b000002a2 (9 bytes) 09:40:42.300 SERIAL » [ACK] (0x06) 09:40:42.300 DRIVER « [REQ] [SendData] callback id: 75 transmit status: OK 09:40:42.311 SERIAL « 0x010c0004002106600c00ffff00bc (14 bytes) 09:40:42.311 SERIAL » [ACK] (0x06) 09:40:42.312 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: # of reports to follow: 0 09:40:42.313 CNTRLR « [Node 033] Endpoint query returned no results, assuming that endpoints are seq uential 09:40:42.314 CNTRLR » [Node 033] querying capabilities for endpoint #1... 09:40:42.317 SERIAL » 0x010a00132103600901254cc5 (12 bytes) 09:40:42.318 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 76 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:40:42.319 SERIAL « [ACK] (0x06) 09:40:42.325 SERIAL « 0x0104011301e8 (6 bytes) 09:40:42.326 SERIAL » [ACK] (0x06) 09:40:42.326 DRIVER « [RES] [SendData] was sent: true 09:40:42.343 SERIAL « 0x010700134c000003a4 (9 bytes) 09:40:42.343 SERIAL » [ACK] (0x06) 09:40:42.343 DRIVER « [REQ] [SendData] callback id: 76 transmit status: OK 09:40:42.354 SERIAL « 0x010c0004002106600a011101268d (14 bytes) 09:40:42.355 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 1] [internal] 8 09:40:42.355 SERIAL » [ACK] (0x06) 09:40:42.355 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Multilevel Switch specific device class: Multilevel Power Switch is dynamic end point: false supported CCs: · Multilevel Switch 09:40:42.356 CNTRLR « [Node 033] received response for endpoint capabilities (#1): generic device class: Multilevel Switch specific device class: Multilevel Power Switch is dynamic end point: false supported CCs: · Multilevel Switch 09:40:42.357 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #2. .. 09:40:42.357 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 2] [internal] 8 09:40:42.357 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #3. .. 09:40:42.357 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 3] [internal] 8 09:40:42.357 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #4. .. 09:40:42.357 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 4] [internal] 8 09:40:42.358 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #5. .. 09:40:42.358 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 5] [internal] 8 09:40:42.358 CNTRLR [Node 033] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:40:42.388 CNTRLR [Node 033] WakeUpCC: doing a complete interview... 09:40:42.388 CNTRLR » [Node 033] retrieving wakeup interval from the device... 09:40:42.392 SERIAL » 0x0109001321028405254d2f (11 bytes) 09:40:42.392 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 77 └─[WakeUpCCIntervalGet] 09:40:42.393 SERIAL « [ACK] (0x06) 09:40:42.400 SERIAL « 0x0104011301e8 (6 bytes) 09:40:42.400 SERIAL » [ACK] (0x06) 09:40:42.400 DRIVER « [RES] [SendData] was sent: true 09:40:42.417 SERIAL « 0x010700134d000002a4 (9 bytes) 09:40:42.417 SERIAL » [ACK] (0x06) 09:40:42.418 DRIVER « [REQ] [SendData] callback id: 77 transmit status: OK 09:40:44.021 CNTRLR [Node 033] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:40:44.526 SERIAL » 0x0109001321028405254d2f (11 bytes) 09:40:44.527 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 77 └─[WakeUpCCIntervalGet] 09:40:44.529 SERIAL « [ACK] (0x06) 09:40:44.535 SERIAL « 0x0104011301e8 (6 bytes) 09:40:44.536 SERIAL » [ACK] (0x06) 09:40:44.536 DRIVER « [RES] [SendData] was sent: true 09:40:44.552 SERIAL « 0x010700134d000003a5 (9 bytes) 09:40:44.553 SERIAL » [ACK] (0x06) 09:40:44.554 DRIVER « [REQ] [SendData] callback id: 77 transmit status: OK 09:40:44.965 SERIAL « 0x01090004001e03300300dc (11 bytes) 09:40:44.966 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:40:44.967 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:40:44.968 SERIAL » [ACK] (0x06) 09:40:44.970 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:40:45.019 SERIAL « 0x01090004001e03200100ce (11 bytes) 09:40:45.020 SERIAL » [ACK] (0x06) 09:40:45.021 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:40:45.023 CNTRLR [Node 030] treating BasicCC Set as a report 09:40:45.024 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:40:46.157 CNTRLR [Node 033] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:40:46.662 SERIAL » 0x0109001321028405254d2f (11 bytes) 09:40:46.663 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 77 └─[WakeUpCCIntervalGet] 09:40:46.665 SERIAL « [ACK] (0x06) 09:40:46.671 SERIAL « 0x0104011301e8 (6 bytes) 09:40:46.671 SERIAL » [ACK] (0x06) 09:40:46.672 DRIVER « [RES] [SendData] was sent: true 09:40:46.688 SERIAL « 0x010700134d000002a4 (9 bytes) 09:40:46.688 SERIAL » [ACK] (0x06) 09:40:46.689 DRIVER « [REQ] [SendData] callback id: 77 transmit status: OK 09:40:47.632 SERIAL « 0x01090004001b03300300d9 (11 bytes) 09:40:47.632 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:40:47.633 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:40:47.633 SERIAL » [ACK] (0x06) 09:40:47.634 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:40:47.686 SERIAL « 0x01090004001b03200100cb (11 bytes) 09:40:47.687 SERIAL » [ACK] (0x06) 09:40:47.687 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:40:47.688 CNTRLR [Node 027] treating BasicCC Set as a report 09:40:47.688 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:40:48.298 CNTRLR [Node 033] Interview attempt 3/5 failed, retrying in 15000 ms... 09:40:49.326 SERIAL « 0x010c00040003063105042204db3f (14 bytes) 09:40:49.327 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:40:49.328 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 255.4 => 124.3 [Endpoint 0] 09:40:49.329 SERIAL » [ACK] (0x06) 09:40:49.331 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 124.3 09:40:53.326 SERIAL « 0x010c00040003063105042208d830 (14 bytes) 09:40:53.326 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:40:53.327 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 124.3 => 226.4 [Endpoint 0] 09:40:53.327 SERIAL » [ACK] (0x06) 09:40:53.328 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 226.4 09:40:54.326 SERIAL « 0x010c0004000306310504220437d3 (14 bytes) 09:40:54.327 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:40:54.328 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 226.4 => 107.9 [Endpoint 0] 09:40:54.329 SERIAL » [ACK] (0x06) 09:40:54.331 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 107.9 09:40:56.326 SERIAL « 0x010c0004000306310504220508ed (14 bytes) 09:40:56.327 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:40:56.328 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 107.9 => 128.8 [Endpoint 0] 09:40:56.329 SERIAL » [ACK] (0x06) 09:40:56.331 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 128.8 09:40:59.326 SERIAL « 0x010c000400030631050422043dd9 (14 bytes) 09:40:59.327 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:40:59.327 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 128.8 => 108.5 [Endpoint 0] 09:40:59.328 SERIAL » [ACK] (0x06) 09:40:59.329 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 108.5 09:41:03.299 CNTRLR [Node 033] Beginning interview - last completed stage: RestartFromCache 09:41:03.299 CNTRLR » [Node 033] pinging the node... 09:41:03.307 SERIAL » 0x01080013210100254eaf (10 bytes) 09:41:03.308 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 78 └─[NoOperationCC] 09:41:03.310 SERIAL « [ACK] (0x06) 09:41:03.316 SERIAL « 0x0104011301e8 (6 bytes) 09:41:03.317 SERIAL » [ACK] (0x06) 09:41:03.317 DRIVER « [RES] [SendData] was sent: true 09:41:03.333 SERIAL « 0x010700134e000003a6 (9 bytes) 09:41:03.334 SERIAL » [ACK] (0x06) 09:41:03.335 DRIVER « [REQ] [SendData] callback id: 78 transmit status: OK 09:41:03.338 CNTRLR « [Node 033] ping successful 09:41:03.340 CNTRLR [Node 033] ManufacturerSpecificCC: doing a partial interview... 09:41:03.350 CNTRLR [Node 033] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:41:03.401 CNTRLR [Node 033] VersionCC: doing a partial interview... 09:41:03.401 CNTRLR [Node 033] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:41:03.402 CNTRLR [Node 033] trying to load device config 09:41:03.413 CNTRLR [Node 033] device config loaded 09:41:03.414 CNTRLR » [Node 033] querying device endpoint information... 09:41:03.419 SERIAL » 0x0109001321026007254fcb (11 bytes) 09:41:03.419 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 79 └─[MultiChannelCCEndPointGet] 09:41:03.421 SERIAL « [ACK] (0x06) 09:41:03.427 SERIAL « 0x0104011301e8 (6 bytes) 09:41:03.427 SERIAL » [ACK] (0x06) 09:41:03.428 DRIVER « [RES] [SendData] was sent: true 09:41:03.444 SERIAL « 0x010700134f000003a7 (9 bytes) 09:41:03.445 SERIAL » [ACK] (0x06) 09:41:03.445 DRIVER « [REQ] [SendData] callback id: 79 transmit status: OK 09:41:03.454 SERIAL « 0x010a000400210460084005f9 (12 bytes) 09:41:03.455 CNTRLR [Node 033] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:41:03.461 CNTRLR [Node 033] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 09:41:03.461 CNTRLR [Node 033] [~] [Multi Channel] individualCount: 5 => 5 [Endpoint 0] [internal] 09:41:03.462 SERIAL » [ACK] (0x06) 09:41:03.462 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 5 count is dynamic: false identical capabilities: true 09:41:03.464 CNTRLR « [Node 033] received response for device endpoints: endpoint count (individual): 5 count is dynamic: false identical capabilities: true 09:41:03.464 CNTRLR » [Node 033] querying all endpoints... 09:41:03.468 SERIAL » 0x010b00132104600bffff2550dc (13 bytes) 09:41:03.469 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 80 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:41:03.470 SERIAL « [ACK] (0x06) 09:41:03.477 SERIAL « 0x0104011301e8 (6 bytes) 09:41:03.477 SERIAL » [ACK] (0x06) 09:41:03.478 DRIVER « [RES] [SendData] was sent: true 09:41:03.494 SERIAL « 0x0107001350000003b8 (9 bytes) 09:41:03.494 SERIAL » [ACK] (0x06) 09:41:03.495 DRIVER « [REQ] [SendData] callback id: 80 transmit status: OK 09:41:03.505 SERIAL « 0x010c0004002106600c00ffff00bc (14 bytes) 09:41:03.506 SERIAL » [ACK] (0x06) 09:41:03.506 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: # of reports to follow: 0 09:41:03.507 CNTRLR « [Node 033] Endpoint query returned no results, assuming that endpoints are seq uential 09:41:03.508 CNTRLR » [Node 033] querying capabilities for endpoint #1... 09:41:03.511 SERIAL » 0x010a001321036009012551d8 (12 bytes) 09:41:03.512 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 81 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:41:03.513 SERIAL « [ACK] (0x06) 09:41:03.520 SERIAL « 0x0104011301e8 (6 bytes) 09:41:03.520 SERIAL » [ACK] (0x06) 09:41:03.520 DRIVER « [RES] [SendData] was sent: true 09:41:03.537 SERIAL « 0x0107001351000002b8 (9 bytes) 09:41:03.537 SERIAL » [ACK] (0x06) 09:41:03.538 DRIVER « [REQ] [SendData] callback id: 81 transmit status: OK 09:41:03.548 SERIAL « 0x010c0004002106600a011101268d (14 bytes) 09:41:03.549 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 1] [internal] 8 09:41:03.549 SERIAL » [ACK] (0x06) 09:41:03.549 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Multilevel Switch specific device class: Multilevel Power Switch is dynamic end point: false supported CCs: · Multilevel Switch 09:41:03.550 CNTRLR « [Node 033] received response for endpoint capabilities (#1): generic device class: Multilevel Switch specific device class: Multilevel Power Switch is dynamic end point: false supported CCs: · Multilevel Switch 09:41:03.551 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #2. .. 09:41:03.551 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 2] [internal] 8 09:41:03.551 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #3. .. 09:41:03.551 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 3] [internal] 8 09:41:03.551 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #4. .. 09:41:03.552 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 4] [internal] 8 09:41:03.552 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #5. .. 09:41:03.552 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 5] [internal] 8 09:41:03.552 CNTRLR [Node 033] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:41:03.680 CNTRLR [Node 033] WakeUpCC: doing a complete interview... 09:41:03.681 CNTRLR » [Node 033] retrieving wakeup interval from the device... 09:41:03.684 SERIAL » 0x0109001321028405255230 (11 bytes) 09:41:03.685 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 82 └─[WakeUpCCIntervalGet] 09:41:03.686 SERIAL « [ACK] (0x06) 09:41:03.692 SERIAL « 0x0104011301e8 (6 bytes) 09:41:03.692 SERIAL » [ACK] (0x06) 09:41:03.693 DRIVER « [RES] [SendData] was sent: true 09:41:03.709 SERIAL « 0x0107001352000002bb (9 bytes) 09:41:03.710 SERIAL » [ACK] (0x06) 09:41:03.710 DRIVER « [REQ] [SendData] callback id: 82 transmit status: OK 09:41:04.327 SERIAL « 0x010c00040003063105042209bb52 (14 bytes) 09:41:04.328 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:41:04.329 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 108.5 => 249.1 [Endpoint 0] 09:41:04.334 SERIAL » [ACK] (0x06) 09:41:04.335 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 249.1 09:41:05.313 CNTRLR [Node 033] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:41:05.818 SERIAL » 0x0109001321028405255230 (11 bytes) 09:41:05.819 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 82 └─[WakeUpCCIntervalGet] 09:41:05.821 SERIAL « [ACK] (0x06) 09:41:05.827 SERIAL « 0x0104011301e8 (6 bytes) 09:41:05.828 SERIAL » [ACK] (0x06) 09:41:05.828 DRIVER « [RES] [SendData] was sent: true 09:41:05.844 SERIAL « 0x0107001352000003ba (9 bytes) 09:41:05.845 SERIAL » [ACK] (0x06) 09:41:05.845 DRIVER « [REQ] [SendData] callback id: 82 transmit status: OK 09:41:06.164 SERIAL « 0x01090004001b033003ff26 (11 bytes) 09:41:06.165 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:41:06.166 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:41:06.167 SERIAL » [ACK] (0x06) 09:41:06.168 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:41:06.218 SERIAL « 0x01090004001b032001ff34 (11 bytes) 09:41:06.219 SERIAL » [ACK] (0x06) 09:41:06.220 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:41:06.221 CNTRLR [Node 027] treating BasicCC Set as a report 09:41:06.222 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:41:07.449 CNTRLR [Node 033] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:41:07.954 SERIAL » 0x0109001321028405255230 (11 bytes) 09:41:07.955 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 82 └─[WakeUpCCIntervalGet] 09:41:07.956 SERIAL « [ACK] (0x06) 09:41:07.964 SERIAL « 0x0104011301e8 (6 bytes) 09:41:07.968 SERIAL » [ACK] (0x06) 09:41:07.969 DRIVER « [RES] [SendData] was sent: true 09:41:07.980 SERIAL « 0x0107001352000002bb (9 bytes) 09:41:07.980 SERIAL » [ACK] (0x06) 09:41:07.981 DRIVER « [REQ] [SendData] callback id: 82 transmit status: OK 09:41:09.586 CNTRLR [Node 033] Interview attempt 4/5 failed, retrying in 20000 ms... 09:41:20.329 SERIAL « 0x010c000400030631050422042bcf (14 bytes) 09:41:20.330 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:41:20.332 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 249.1 => 106.7 [Endpoint 0] 09:41:20.333 SERIAL » [ACK] (0x06) 09:41:20.335 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 106.7 09:41:21.329 SERIAL « 0x010c000400030631050422054aaf (14 bytes) 09:41:21.330 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:41:21.331 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 106.7 => 135.4 [Endpoint 0] 09:41:21.332 SERIAL » [ACK] (0x06) 09:41:21.334 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 135.4 09:41:22.329 SERIAL « 0x010c000400030631050422046286 (14 bytes) 09:41:22.330 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:41:22.331 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 135.4 => 112.2 [Endpoint 0] 09:41:22.332 SERIAL » [ACK] (0x06) 09:41:22.334 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 112.2 09:41:23.329 SERIAL « 0x010c00040003063105042208db33 (14 bytes) 09:41:23.330 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:41:23.332 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 112.2 => 226.7 [Endpoint 0] 09:41:23.333 SERIAL » [ACK] (0x06) 09:41:23.335 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 226.7 09:41:24.329 SERIAL « 0x010c00040003063105042203b152 (14 bytes) 09:41:24.330 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:41:24.331 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 226.7 => 94.5 [Endpoint 0] 09:41:24.331 SERIAL » [ACK] (0x06) 09:41:24.333 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 94.5 09:41:29.383 SERIAL « 0x01090004102003300300f2 (11 bytes) 09:41:29.388 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:41:29.396 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:41:29.397 SERIAL » [ACK] (0x06) 09:41:29.405 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:41:29.428 SERIAL « 0x01090004002003200100f0 (11 bytes) 09:41:29.429 SERIAL » [ACK] (0x06) 09:41:29.431 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:41:29.434 CNTRLR [Node 032] treating BasicCC Set as a report 09:41:29.435 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:41:29.488 SERIAL « 0x01090004102003300300f2 (11 bytes) 09:41:29.489 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:41:29.491 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:41:29.492 SERIAL » [ACK] (0x06) 09:41:29.494 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:41:29.587 CNTRLR [Node 033] Beginning interview - last completed stage: RestartFromCache 09:41:29.588 CNTRLR » [Node 033] pinging the node... 09:41:29.601 SERIAL » 0x010800132101002553b2 (10 bytes) 09:41:29.602 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 83 └─[NoOperationCC] 09:41:29.606 SERIAL « 0x01090004102003300300f2 (11 bytes) 09:41:29.607 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:41:29.608 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:41:29.609 SERIAL » [ACK] (0x06) 09:41:29.611 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:41:29.615 SERIAL « [CAN] (0x18) 09:41:29.618 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 09:41:29.641 SERIAL « 0x01090004102003300300f2 (11 bytes) 09:41:29.642 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:41:29.644 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:41:29.645 SERIAL » [ACK] (0x06) 09:41:29.647 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:41:29.703 SERIAL « 0x01090004102003300300f2 (11 bytes) 09:41:29.704 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:41:29.705 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:41:29.705 SERIAL » [ACK] (0x06) 09:41:29.707 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:41:29.722 SERIAL » 0x010800132101002553b2 (10 bytes) 09:41:29.723 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 83 └─[NoOperationCC] 09:41:29.725 SERIAL « [ACK] (0x06) 09:41:29.732 SERIAL « 0x0104011301e8 (6 bytes) 09:41:29.732 SERIAL » [ACK] (0x06) 09:41:29.733 DRIVER « [RES] [SendData] was sent: true 09:41:29.750 SERIAL « 0x0107001353000002ba (9 bytes) 09:41:29.750 SERIAL » [ACK] (0x06) 09:41:29.751 DRIVER « [REQ] [SendData] callback id: 83 transmit status: OK 09:41:29.755 CNTRLR « [Node 033] ping successful 09:41:29.758 CNTRLR [Node 033] ManufacturerSpecificCC: doing a partial interview... 09:41:29.759 CNTRLR [Node 033] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 09:41:29.818 SERIAL « 0x01090004102003300300f2 (11 bytes) 09:41:29.818 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:41:29.819 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:41:29.820 SERIAL » [ACK] (0x06) 09:41:29.823 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:41:29.826 CNTRLR [Node 033] VersionCC: doing a partial interview... 09:41:29.827 CNTRLR [Node 033] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:41:29.828 CNTRLR [Node 033] trying to load device config 09:41:29.840 CNTRLR [Node 033] device config loaded 09:41:29.840 CNTRLR » [Node 033] querying device endpoint information... 09:41:29.847 SERIAL » 0x01090013210260072554d0 (11 bytes) 09:41:29.847 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 84 └─[MultiChannelCCEndPointGet] 09:41:29.850 SERIAL « [ACK] (0x06) 09:41:29.856 SERIAL « 0x0104011301e8 (6 bytes) 09:41:29.856 SERIAL » [ACK] (0x06) 09:41:29.857 DRIVER « [RES] [SendData] was sent: true 09:41:29.873 SERIAL « 0x0107001354000003bc (9 bytes) 09:41:29.873 SERIAL » [ACK] (0x06) 09:41:29.874 DRIVER « [REQ] [SendData] callback id: 84 transmit status: OK 09:41:29.883 SERIAL « 0x010a000400210460084005f9 (12 bytes) 09:41:29.884 CNTRLR [Node 033] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 09:41:29.884 CNTRLR [Node 033] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 09:41:29.885 CNTRLR [Node 033] [~] [Multi Channel] individualCount: 5 => 5 [Endpoint 0] [internal] 09:41:29.885 SERIAL » [ACK] (0x06) 09:41:29.886 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 5 count is dynamic: false identical capabilities: true 09:41:29.887 CNTRLR « [Node 033] received response for device endpoints: endpoint count (individual): 5 count is dynamic: false identical capabilities: true 09:41:29.888 CNTRLR » [Node 033] querying all endpoints... 09:41:29.896 SERIAL » 0x010b00132104600bffff2555d9 (13 bytes) 09:41:29.897 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 85 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 09:41:29.898 SERIAL « [ACK] (0x06) 09:41:29.905 SERIAL « 0x0104011301e8 (6 bytes) 09:41:29.905 SERIAL » [ACK] (0x06) 09:41:29.906 DRIVER « [RES] [SendData] was sent: true 09:41:29.923 SERIAL « 0x0107001355000003bd (9 bytes) 09:41:29.923 SERIAL » [ACK] (0x06) 09:41:29.924 DRIVER « [REQ] [SendData] callback id: 85 transmit status: OK 09:41:29.934 SERIAL « 0x010c0004002106600c00ffff00bc (14 bytes) 09:41:29.935 SERIAL » [ACK] (0x06) 09:41:29.936 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: # of reports to follow: 0 09:41:29.938 CNTRLR « [Node 033] Endpoint query returned no results, assuming that endpoints are seq uential 09:41:29.938 CNTRLR » [Node 033] querying capabilities for endpoint #1... 09:41:29.945 SERIAL » 0x010a001321036009012556df (12 bytes) 09:41:29.945 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 86 └─[MultiChannelCCCapabilityGet] endpoint: 1 09:41:29.947 SERIAL « [ACK] (0x06) 09:41:29.953 SERIAL « 0x0104011301e8 (6 bytes) 09:41:29.953 SERIAL » [ACK] (0x06) 09:41:29.954 DRIVER « [RES] [SendData] was sent: true 09:41:29.971 SERIAL « 0x0107001356000002bf (9 bytes) 09:41:29.971 SERIAL » [ACK] (0x06) 09:41:29.972 DRIVER « [REQ] [SendData] callback id: 86 transmit status: OK 09:41:29.983 SERIAL « 0x010c0004002106600a011101268d (14 bytes) 09:41:29.984 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 1] [internal] 8 09:41:29.984 SERIAL » [ACK] (0x06) 09:41:29.985 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Multilevel Switch specific device class: Multilevel Power Switch is dynamic end point: false supported CCs: · Multilevel Switch 09:41:29.987 CNTRLR « [Node 033] received response for endpoint capabilities (#1): generic device class: Multilevel Switch specific device class: Multilevel Power Switch is dynamic end point: false supported CCs: · Multilevel Switch 09:41:29.987 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #2. .. 09:41:29.987 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 2] [internal] 8 09:41:29.987 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #3. .. 09:41:29.988 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 3] [internal] 8 09:41:29.988 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #4. .. 09:41:29.988 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 4] [internal] 8 09:41:29.988 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #5. .. 09:41:29.989 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 5] [internal] 8 09:41:29.989 CNTRLR [Node 033] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 09:41:30.035 SERIAL « 0x01090004102003300300f2 (11 bytes) 09:41:30.036 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:41:30.037 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:41:30.038 SERIAL » [ACK] (0x06) 09:41:30.039 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:41:30.041 CNTRLR [Node 033] WakeUpCC: doing a complete interview... 09:41:30.041 CNTRLR » [Node 033] retrieving wakeup interval from the device... 09:41:30.050 SERIAL » 0x0109001321028405255735 (11 bytes) 09:41:30.051 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 87 └─[WakeUpCCIntervalGet] 09:41:30.054 SERIAL « [ACK] (0x06) 09:41:30.059 SERIAL « 0x0104011301e8 (6 bytes) 09:41:30.060 SERIAL » [ACK] (0x06) 09:41:30.061 DRIVER « [RES] [SendData] was sent: true 09:41:30.076 SERIAL « 0x0107001357000002be (9 bytes) 09:41:30.077 SERIAL » [ACK] (0x06) 09:41:30.077 DRIVER « [REQ] [SendData] callback id: 87 transmit status: OK 09:41:31.330 SERIAL « 0x010c00040003063105042209739a (14 bytes) 09:41:31.332 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:41:31.333 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 94.5 => 241.9 [Endpoint 0] 09:41:31.334 SERIAL » [ACK] (0x06) 09:41:31.337 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 241.9 09:41:31.684 CNTRLR [Node 033] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:41:32.188 SERIAL » 0x0109001321028405255735 (11 bytes) 09:41:32.189 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 87 └─[WakeUpCCIntervalGet] 09:41:32.190 SERIAL « [ACK] (0x06) 09:41:32.197 SERIAL « 0x0104011301e8 (6 bytes) 09:41:32.197 SERIAL » [ACK] (0x06) 09:41:32.198 DRIVER « [RES] [SendData] was sent: true 09:41:32.214 SERIAL « 0x0107001357000003bf (9 bytes) 09:41:32.214 SERIAL » [ACK] (0x06) 09:41:32.215 DRIVER « [REQ] [SendData] callback id: 87 transmit status: OK 09:41:33.819 CNTRLR [Node 033] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 09:41:34.070 SERIAL « 0x01090004000803300300ca (11 bytes) 09:41:34.071 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:41:34.073 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:41:34.074 SERIAL » [ACK] (0x06) 09:41:34.076 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:41:34.124 SERIAL « 0x01090004000803200100d8 (11 bytes) 09:41:34.125 SERIAL » [ACK] (0x06) 09:41:34.126 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:41:34.127 CNTRLR [Node 008] treating BasicCC Set as a report 09:41:34.128 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:41:34.326 SERIAL » 0x0109001321028405255735 (11 bytes) 09:41:34.327 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 87 └─[WakeUpCCIntervalGet] 09:41:34.329 SERIAL « [ACK] (0x06) 09:41:34.335 SERIAL « 0x0104011301e8 (6 bytes) 09:41:34.335 SERIAL » [ACK] (0x06) 09:41:34.337 DRIVER « [RES] [SendData] was sent: true 09:41:34.352 SERIAL « 0x0107001357000002be (9 bytes) 09:41:34.353 SERIAL » [ACK] (0x06) 09:41:34.356 DRIVER « [REQ] [SendData] callback id: 87 transmit status: OK 09:41:35.964 CNTRLR [Node 033] Failed all interview attempts, giving up. 09:41:45.002 SERIAL » 0x010e00131f07600d00012501002558cf (16 bytes) 09:41:45.004 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 88 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCSet] target value: false 09:41:45.006 SERIAL « [ACK] (0x06) 09:41:45.013 SERIAL « 0x0104011301e8 (6 bytes) 09:41:45.013 SERIAL » [ACK] (0x06) 09:41:45.014 DRIVER « [RES] [SendData] was sent: true 09:41:45.032 SERIAL « 0x0107001358000002b1 (9 bytes) 09:41:45.032 SERIAL » [ACK] (0x06) 09:41:45.033 DRIVER « [REQ] [SendData] callback id: 88 transmit status: OK 09:41:45.047 SERIAL » 0x010d00131f06600d000125022559cf (15 bytes) 09:41:45.048 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 89 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 09:41:45.052 SERIAL « [ACK] (0x06) 09:41:45.058 SERIAL « 0x0104011301e8 (6 bytes) 09:41:45.059 SERIAL » [ACK] (0x06) 09:41:45.060 DRIVER « [RES] [SendData] was sent: true 09:41:45.075 SERIAL « 0x0107001359000003b1 (9 bytes) 09:41:45.076 SERIAL » [ACK] (0x06) 09:41:45.077 DRIVER « [REQ] [SendData] callback id: 89 transmit status: OK 09:41:45.086 SERIAL « 0x010d0004001f07600d0100250300a4 (15 bytes) 09:41:45.089 CNTRLR [Node 031] [~] [Binary Switch] currentValue: true => false [Endpoint 1] 09:41:45.090 SERIAL » [ACK] (0x06) 09:41:45.093 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: false 09:41:49.337 SERIAL « 0x01080004102002840742 (10 bytes) 09:41:49.338 SERIAL » [ACK] (0x06) 09:41:49.340 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:41:49.344 CNTRLR « [Node 032] received wakeup notification 09:41:49.346 CNTRLR [Node 032] The node is now awake. 09:41:49.360 SERIAL » 0x0109001320028002255a3a (11 bytes) 09:41:49.361 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 90 └─[BatteryCCGet] 09:41:49.369 SERIAL « [ACK] (0x06) 09:41:49.373 SERIAL « 0x0104011301e8 (6 bytes) 09:41:49.374 SERIAL » [ACK] (0x06) 09:41:49.380 DRIVER « [RES] [SendData] was sent: true 09:41:49.388 SERIAL « 0x01080004102002840742 (10 bytes) 09:41:49.388 SERIAL » [ACK] (0x06) 09:41:49.389 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:41:49.391 CNTRLR « [Node 032] received wakeup notification 09:41:49.393 SERIAL « 0x01080004102002840742 (10 bytes) 09:41:49.394 SERIAL » [ACK] (0x06) 09:41:49.395 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:41:49.397 CNTRLR « [Node 032] received wakeup notification 09:41:49.426 SERIAL « 0x010700135a000006b7 (9 bytes) 09:41:49.427 SERIAL » [ACK] (0x06) 09:41:49.428 DRIVER « [REQ] [SendData] callback id: 90 transmit status: OK 09:41:49.487 SERIAL « 0x01080004102002840742 (10 bytes) 09:41:49.488 SERIAL » [ACK] (0x06) 09:41:49.489 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:41:49.491 CNTRLR « [Node 032] received wakeup notification 09:41:49.603 SERIAL « 0x01080004102002840742 (10 bytes) 09:41:49.604 SERIAL » [ACK] (0x06) 09:41:49.605 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:41:49.612 CNTRLR « [Node 032] received wakeup notification 09:41:49.713 SERIAL « 0x0109000400200380036436 (11 bytes) 09:41:49.715 CNTRLR [Node 032] [~] [Battery] level: 100 => 100 [Endpoint 0] 09:41:49.721 CNTRLR [Node 032] [~] [Battery] isLow: false => false [Endpoint 0] 09:41:49.722 SERIAL » [ACK] (0x06) 09:41:49.725 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 09:41:49.728 CNTRLR « [Node 032] received response for battery information: level: 100 09:41:49.729 CNTRLR [Node 032] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:41:49.731 SERIAL « 0x01080004102002840742 (10 bytes) 09:41:49.732 SERIAL » [ACK] (0x06) 09:41:49.815 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:41:49.818 CNTRLR « [Node 032] received wakeup notification 09:41:49.824 SERIAL « 0x01080004102002840742 (10 bytes) 09:41:49.824 SERIAL » [ACK] (0x06) 09:41:49.826 CNTRLR [Node 032] WakeUpCC: doing a partial interview... 09:41:49.826 CNTRLR » [Node 032] retrieving wakeup interval from the device... 09:41:49.832 SERIAL » 0x0109001320028405255b38 (11 bytes) 09:41:49.832 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 91 └─[WakeUpCCIntervalGet] 09:41:49.833 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:41:49.834 CNTRLR « [Node 032] received wakeup notification 09:41:49.836 SERIAL « 0x01080004102002840742 (10 bytes) 09:41:49.836 SERIAL » [ACK] (0x06) 09:41:49.837 SERIAL « [CAN] (0x18) 09:41:49.838 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 09:41:49.840 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:41:49.841 CNTRLR « [Node 032] received wakeup notification 09:41:49.842 SERIAL « 0x01080004102002840742 (10 bytes) 09:41:49.843 SERIAL » [ACK] (0x06) 09:41:49.843 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:41:49.845 CNTRLR « [Node 032] received wakeup notification 09:41:49.859 SERIAL « 0x01080004102002840742 (10 bytes) 09:41:49.859 SERIAL » [ACK] (0x06) 09:41:49.860 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:41:49.862 CNTRLR « [Node 032] received wakeup notification 09:41:49.939 SERIAL » 0x0109001320028405255b38 (11 bytes) 09:41:49.940 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 91 └─[WakeUpCCIntervalGet] 09:41:49.942 SERIAL « [ACK] (0x06) 09:41:49.948 SERIAL « 0x0104011301e8 (6 bytes) 09:41:49.948 SERIAL » [ACK] (0x06) 09:41:49.948 DRIVER « [RES] [SendData] was sent: true 09:41:49.994 SERIAL « 0x01080004102002840742 (10 bytes) 09:41:49.994 SERIAL » [ACK] (0x06) 09:41:49.995 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:41:49.996 CNTRLR « [Node 032] received wakeup notification 09:41:50.049 SERIAL « 0x010700135b00000bbb (9 bytes) 09:41:50.049 SERIAL » [ACK] (0x06) 09:41:50.050 DRIVER « [REQ] [SendData] callback id: 91 transmit status: OK 09:41:50.185 SERIAL « 0x010c0004002006840600038401d5 (14 bytes) 09:41:50.186 CNTRLR [Node 032] [~] [Wake Up] wakeUpInterval: 900 => 900 [Endpoint 0] 09:41:50.187 CNTRLR [Node 032] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 09:41:50.187 SERIAL » [ACK] (0x06) 09:41:50.189 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 900 seconds controller node id: 1 09:41:50.190 CNTRLR « [Node 032] received wakeup configuration: wakeup interval: 900 seconds controller node: 1 09:41:50.191 CNTRLR [Node 032] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:41:50.230 CNTRLR [Node 032] AssociationCC: doing a partial interview... 09:41:50.231 CNTRLR [Node 032] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 09:41:50.231 CNTRLR [Node 032] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:41:50.232 CNTRLR [Node 032] BasicCC: doing a partial interview... 09:41:50.232 CNTRLR » [Node 032] querying Basic CC state... 09:41:50.237 SERIAL » 0x0109001320022002255c9c (11 bytes) 09:41:50.238 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 92 └─[BasicCCGet] 09:41:50.239 SERIAL « [ACK] (0x06) 09:41:50.245 SERIAL « 0x0104011301e8 (6 bytes) 09:41:50.245 SERIAL » [ACK] (0x06) 09:41:50.246 DRIVER « [RES] [SendData] was sent: true 09:41:50.306 SERIAL « 0x010700135c000007b0 (9 bytes) 09:41:50.306 SERIAL » [ACK] (0x06) 09:41:50.307 DRIVER « [REQ] [SendData] callback id: 92 transmit status: OK 09:41:50.354 SERIAL « 0x01090004002003200300f2 (11 bytes) 09:41:50.355 SERIAL » [ACK] (0x06) 09:41:50.356 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCReport] current value: 0 09:41:50.358 CNTRLR « [Node 032] received Basic CC state: current value: 0 09:41:50.359 CNTRLR [Node 032] [~] [Basic] interviewComplete: true => true [Endpoint 0] [internal] 09:41:50.359 CNTRLR [Node 032] BinarySensorCC: doing a partial interview... 09:41:50.359 CNTRLR » [Node 032] querying current value... 09:41:50.368 SERIAL » 0x0109001320023002255d8d (11 bytes) 09:41:50.369 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 93 └─[BinarySensorCCGet] type: Any 09:41:50.370 SERIAL « [ACK] (0x06) 09:41:50.377 SERIAL « 0x0104011301e8 (6 bytes) 09:41:50.377 SERIAL » [ACK] (0x06) 09:41:50.377 DRIVER « [RES] [SendData] was sent: true 09:41:50.476 SERIAL « 0x010700135d00000bbd (9 bytes) 09:41:50.476 SERIAL » [ACK] (0x06) 09:41:50.476 DRIVER « [REQ] [SendData] callback id: 93 transmit status: OK 09:41:50.525 SERIAL « 0x01090004002003300300e2 (11 bytes) 09:41:50.526 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:41:50.527 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:41:50.528 SERIAL » [ACK] (0x06) 09:41:50.529 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:41:50.533 CNTRLR « [Node 032] received current value: false 09:41:50.533 CNTRLR [Node 032] [~] [Binary Sensor] interviewComplete: true [Endpoint 0] [internal] => true 09:41:50.534 CNTRLR [Node 032] MultilevelSensorCC: doing a partial interview... 09:41:50.534 CNTRLR » [Node 032] querying Air temperature sensor reading... 09:41:50.543 SERIAL » 0x010b0013200431040100255e8c (13 bytes) 09:41:50.543 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 94 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:41:50.546 SERIAL « [ACK] (0x06) 09:41:50.552 SERIAL « 0x0104011301e8 (6 bytes) 09:41:50.553 SERIAL » [ACK] (0x06) 09:41:50.554 DRIVER « [RES] [SendData] was sent: true 09:41:50.647 SERIAL « 0x010700135e00000abf (9 bytes) 09:41:50.647 SERIAL » [ACK] (0x06) 09:41:50.648 DRIVER « [REQ] [SendData] callback id: 94 transmit status: OK 09:41:50.674 SERIAL « 0x01080004001102840763 (10 bytes) 09:41:50.674 SERIAL » [ACK] (0x06) 09:41:50.675 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:41:50.677 CNTRLR « [Node 017] received wakeup notification 09:41:50.677 CNTRLR [Node 017] The node is now awake. 09:41:50.850 SERIAL « 0x010c00040020063105012200bd7b (14 bytes) 09:41:50.851 CNTRLR [Node 032] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 09:41:50.853 CNTRLR [Node 032] [~] [Multilevel Sensor] Air temperature: 19 => 18.9 [Endpoint 0] 09:41:50.854 SERIAL » [ACK] (0x06) 09:41:50.855 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.9 09:41:50.861 SERIAL » 0x0109001311028002255f0e (11 bytes) 09:41:50.862 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 95 └─[BatteryCCGet] 09:41:50.863 CNTRLR « [Node 032] received current Air temperature sensor reading: 18.9 °C 09:41:50.864 CNTRLR » [Node 032] querying Illuminance sensor reading... 09:41:50.870 SERIAL « [ACK] (0x06) 09:41:50.875 SERIAL « 0x0104011301e8 (6 bytes) 09:41:50.876 SERIAL » [ACK] (0x06) 09:41:50.877 DRIVER « [RES] [SendData] was sent: true 09:41:50.939 SERIAL « 0x010700135f000007b3 (9 bytes) 09:41:50.940 SERIAL » [ACK] (0x06) 09:41:50.941 DRIVER « [REQ] [SendData] callback id: 95 transmit status: OK 09:41:50.951 SERIAL « 0x0109000400110380036407 (11 bytes) 09:41:50.952 CNTRLR [Node 017] [~] [Battery] level: 100 => 100 [Endpoint 0] 09:41:50.953 CNTRLR [Node 017] [~] [Battery] isLow: false => false [Endpoint 0] 09:41:50.954 SERIAL » [ACK] (0x06) 09:41:50.956 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 09:41:50.962 SERIAL » 0x010b00132004310403082560b8 (13 bytes) 09:41:50.963 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 96 └─[MultilevelSensorCCGet] sensor type: Illuminance scale: Lux 09:41:50.964 CNTRLR « [Node 017] received response for battery information: level: 100 09:41:50.965 CNTRLR [Node 017] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:41:51.025 SERIAL « [ACK] (0x06) 09:41:51.036 SERIAL « 0x0104011301e8 (6 bytes) 09:41:51.036 SERIAL » [ACK] (0x06) 09:41:51.037 DRIVER « [RES] [SendData] was sent: true 09:41:51.040 CNTRLR [Node 017] WakeUpCC: doing a partial interview... 09:41:51.040 CNTRLR » [Node 017] retrieving wakeup interval from the device... 09:41:51.043 SERIAL « 0x01070013600000068d (9 bytes) 09:41:51.043 SERIAL » [ACK] (0x06) 09:41:51.043 DRIVER « [REQ] [SendData] callback id: 96 transmit status: OK 09:41:51.104 SERIAL « 0x010c00040020063105030a003fd3 (14 bytes) 09:41:51.105 CNTRLR [Node 032] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 09:41:51.105 CNTRLR [Node 032] [~] [Multilevel Sensor] Illuminance: 46 => 63 [Endpoint 0] 09:41:51.106 SERIAL » [ACK] (0x06) 09:41:51.107 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 63 09:41:51.110 SERIAL » 0x0109001311028405256133 (11 bytes) 09:41:51.110 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 97 └─[WakeUpCCIntervalGet] 09:41:51.111 CNTRLR « [Node 032] received current Illuminance sensor reading: 63 Lux 09:41:51.111 CNTRLR [Node 032] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 09:41:51.112 CNTRLR [Node 032] ConfigurationCC: Loading configuration parameters from device confi g 09:41:51.121 CNTRLR [Node 032] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:41:51.122 CNTRLR [Node 032] [Configuration] 1: metadata updated 09:41:51.123 CNTRLR [Node 032] [Configuration] 2: metadata updated 09:41:51.124 CNTRLR [Node 032] [Configuration] 3: metadata updated 09:41:51.125 CNTRLR [Node 032] [Configuration] 4: metadata updated 09:41:51.126 CNTRLR [Node 032] [Configuration] 6: metadata updated 09:41:51.128 CNTRLR [Node 032] [Configuration] 8: metadata updated 09:41:51.129 CNTRLR [Node 032] [Configuration] 9: metadata updated 09:41:51.130 CNTRLR [Node 032] [Configuration] 12: metadata updated 09:41:51.131 CNTRLR [Node 032] [Configuration] 14: metadata updated 09:41:51.132 CNTRLR [Node 032] [Configuration] 16: metadata updated 09:41:51.133 CNTRLR [Node 032] [Configuration] 20: metadata updated 09:41:51.135 CNTRLR [Node 032] [Configuration] 22: metadata updated 09:41:51.136 CNTRLR [Node 032] [Configuration] 24: metadata updated 09:41:51.137 CNTRLR [Node 032] [Configuration] 26: metadata updated 09:41:51.138 CNTRLR [Node 032] [Configuration] 40: metadata updated 09:41:51.139 CNTRLR [Node 032] [Configuration] 42: metadata updated 09:41:51.140 CNTRLR [Node 032] [Configuration] 60: metadata updated 09:41:51.141 CNTRLR [Node 032] [Configuration] 62: metadata updated 09:41:51.142 CNTRLR [Node 032] [Configuration] 64: metadata updated 09:41:51.143 CNTRLR [Node 032] [Configuration] 66: metadata updated 09:41:51.145 CNTRLR [Node 032] [Configuration] 80: metadata updated 09:41:51.150 CNTRLR [Node 032] [Configuration] 81: metadata updated 09:41:51.152 CNTRLR [Node 032] [Configuration] 82: metadata updated 09:41:51.153 CNTRLR [Node 032] [Configuration] 83: metadata updated 09:41:51.154 CNTRLR [Node 032] [Configuration] 86: metadata updated 09:41:51.155 CNTRLR [Node 032] [Configuration] 87: metadata updated 09:41:51.156 CNTRLR [Node 032] [Configuration] 89: metadata updated 09:41:51.157 CNTRLR [Node 032] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:41:51.158 CNTRLR » [Node 032] querying parameter #1 value... 09:41:51.180 SERIAL « [ACK] (0x06) 09:41:51.181 SERIAL « 0x0104011301e8 (6 bytes) 09:41:51.182 SERIAL » [ACK] (0x06) 09:41:51.184 DRIVER « [RES] [SendData] was sent: true 09:41:51.213 SERIAL « 0x010700136100000983 (9 bytes) 09:41:51.213 SERIAL » [ACK] (0x06) 09:41:51.214 DRIVER « [REQ] [SendData] callback id: 97 transmit status: OK 09:41:51.224 SERIAL « 0x010c0004001106840600038401e4 (14 bytes) 09:41:51.225 CNTRLR [Node 017] [~] [Wake Up] wakeUpInterval: 900 => 900 [Endpoint 0] 09:41:51.226 CNTRLR [Node 017] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 09:41:51.226 SERIAL » [ACK] (0x06) 09:41:51.228 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 900 seconds controller node id: 1 09:41:51.234 SERIAL » 0x010a001320037005012562f6 (12 bytes) 09:41:51.235 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 98 └─[ConfigurationCCGet] parameter #: 1 09:41:51.242 CNTRLR « [Node 017] received wakeup configuration: wakeup interval: 900 seconds controller node: 1 09:41:51.242 CNTRLR [Node 017] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:41:51.292 SERIAL « [ACK] (0x06) 09:41:51.312 SERIAL « 0x0104011301e8 (6 bytes) 09:41:51.312 SERIAL » [ACK] (0x06) 09:41:51.320 DRIVER « [RES] [SendData] was sent: true 09:41:51.336 CNTRLR [Node 017] AssociationCC: doing a partial interview... 09:41:51.337 CNTRLR [Node 017] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 09:41:51.338 CNTRLR [Node 017] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:41:51.339 CNTRLR [Node 017] BasicCC: doing a partial interview... 09:41:51.339 CNTRLR » [Node 017] querying Basic CC state... 09:41:51.349 SERIAL « 0x010c000400030631050422048d69 (14 bytes) 09:41:51.349 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:41:51.350 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 241.9 => 116.5 [Endpoint 0] 09:41:51.351 SERIAL » [ACK] (0x06) 09:41:51.353 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 116.5 09:41:51.820 SERIAL « 0x0107001362000039b0 (9 bytes) 09:41:51.821 SERIAL » [ACK] (0x06) 09:41:51.826 DRIVER « [REQ] [SendData] callback id: 98 transmit status: OK 09:41:51.950 SERIAL « 0x010b0004002005700601010aa9 (13 bytes) 09:41:51.960 CNTRLR [Node 032] [~] [Configuration] 1: 10 => 10 09:41:51.962 SERIAL » [ACK] (0x06) 09:41:51.963 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 10 09:41:51.969 SERIAL » 0x0109001311022002256392 (11 bytes) 09:41:51.970 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 99 └─[BasicCCGet] 09:41:51.971 CNTRLR « [Node 032] parameter #1 has value: 10 09:41:51.971 CNTRLR » [Node 032] querying parameter #2 value... 09:41:51.978 SERIAL « [ACK] (0x06) 09:41:51.982 SERIAL « 0x0104011301e8 (6 bytes) 09:41:51.983 SERIAL » [ACK] (0x06) 09:41:51.985 DRIVER « [RES] [SendData] was sent: true 09:41:52.039 SERIAL « 0x01070013630000068e (9 bytes) 09:41:52.040 SERIAL » [ACK] (0x06) 09:41:52.040 DRIVER « [REQ] [SendData] callback id: 99 transmit status: OK 09:41:52.049 SERIAL « 0x01090004001103200300c3 (11 bytes) 09:41:52.050 SERIAL » [ACK] (0x06) 09:41:52.051 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BasicCCReport] current value: 0 09:41:52.057 SERIAL » 0x010a001320037005022564f3 (12 bytes) 09:41:52.058 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 100 └─[ConfigurationCCGet] parameter #: 2 09:41:52.059 CNTRLR « [Node 017] received Basic CC state: current value: 0 09:41:52.060 CNTRLR [Node 017] [~] [Basic] interviewComplete: true => true [Endpoint 0] [internal] 09:41:52.104 SERIAL « [ACK] (0x06) 09:41:52.108 SERIAL « 0x0104011301e8 (6 bytes) 09:41:52.109 SERIAL » [ACK] (0x06) 09:41:52.109 DRIVER « [RES] [SendData] was sent: true 09:41:52.112 SERIAL « 0x01070013640000058a (9 bytes) 09:41:52.112 SERIAL » [ACK] (0x06) 09:41:52.113 DRIVER « [REQ] [SendData] callback id: 100 transmit status: OK 09:41:52.116 CNTRLR [Node 017] BinarySensorCC: doing a partial interview... 09:41:52.117 CNTRLR » [Node 017] querying current value... 09:41:52.153 SERIAL « 0x010b0004002005700602010faf (13 bytes) 09:41:52.160 CNTRLR [Node 032] [~] [Configuration] 2: 15 => 15 09:41:52.161 SERIAL » [ACK] (0x06) 09:41:52.162 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 15 09:41:52.166 SERIAL » 0x0109001311023002256584 (11 bytes) 09:41:52.167 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 101 └─[BinarySensorCCGet] type: Any 09:41:52.167 CNTRLR « [Node 032] parameter #2 has value: 15 09:41:52.167 CNTRLR » [Node 032] querying parameter #3 value... 09:41:52.172 SERIAL « [ACK] (0x06) 09:41:52.177 SERIAL « 0x0104011301e8 (6 bytes) 09:41:52.177 SERIAL » [ACK] (0x06) 09:41:52.178 DRIVER « [RES] [SendData] was sent: true 09:41:52.239 SERIAL « 0x010700136500000789 (9 bytes) 09:41:52.239 SERIAL » [ACK] (0x06) 09:41:52.240 DRIVER « [REQ] [SendData] callback id: 101 transmit status: OK 09:41:52.249 SERIAL « 0x01090004001103300300d3 (11 bytes) 09:41:52.250 CNTRLR [Node 017] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:41:52.251 CNTRLR [Node 017] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:41:52.251 SERIAL » [ACK] (0x06) 09:41:52.252 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:41:52.256 SERIAL » 0x010a001320037005032566f0 (12 bytes) 09:41:52.256 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 102 └─[ConfigurationCCGet] parameter #: 3 09:41:52.257 CNTRLR « [Node 017] received current value: false 09:41:52.257 CNTRLR [Node 017] [~] [Binary Sensor] interviewComplete: true [Endpoint 0] [internal] => true 09:41:52.257 CNTRLR [Node 017] MultilevelSensorCC: doing a partial interview... 09:41:52.257 CNTRLR » [Node 017] querying Air temperature sensor reading... 09:41:52.263 SERIAL « [ACK] (0x06) 09:41:52.265 SERIAL « 0x0104011301e8 (6 bytes) 09:41:52.265 SERIAL » [ACK] (0x06) 09:41:52.266 DRIVER « [RES] [SendData] was sent: true 09:41:52.302 SERIAL « 0x010700136600000489 (9 bytes) 09:41:52.303 SERIAL » [ACK] (0x06) 09:41:52.303 DRIVER « [REQ] [SendData] callback id: 102 transmit status: OK 09:41:52.351 SERIAL « 0x010b00040020057006030101a0 (13 bytes) 09:41:52.356 CNTRLR [Node 032] [~] [Configuration] 3: 1 => 1 09:41:52.357 SERIAL » [ACK] (0x06) 09:41:52.359 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 1 09:41:52.363 SERIAL » 0x010b0013110431040100256784 (13 bytes) 09:41:52.364 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 103 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:41:52.365 CNTRLR « [Node 032] parameter #3 has value: 1 09:41:52.365 CNTRLR » [Node 032] querying parameter #4 value... 09:41:52.370 SERIAL « [ACK] (0x06) 09:41:52.375 SERIAL « 0x0104011301e8 (6 bytes) 09:41:52.375 SERIAL » [ACK] (0x06) 09:41:52.377 DRIVER « [RES] [SendData] was sent: true 09:41:52.440 SERIAL « 0x01070013670000078b (9 bytes) 09:41:52.440 SERIAL » [ACK] (0x06) 09:41:52.441 DRIVER « [REQ] [SendData] callback id: 103 transmit status: OK 09:41:52.451 SERIAL « 0x010c00040011063105012200de29 (14 bytes) 09:41:52.451 CNTRLR [Node 017] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 09:41:52.452 CNTRLR [Node 017] [~] [Multilevel Sensor] Air temperature: 22.5 => 22.2 [Endpoint 0] 09:41:52.452 SERIAL » [ACK] (0x06) 09:41:52.453 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 22.2 09:41:52.457 SERIAL » 0x010a001320037005042568f9 (12 bytes) 09:41:52.457 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 104 └─[ConfigurationCCGet] parameter #: 4 09:41:52.458 CNTRLR « [Node 017] received current Air temperature sensor reading: 22.2 °C 09:41:52.458 CNTRLR » [Node 017] querying Illuminance sensor reading... 09:41:52.462 SERIAL « [ACK] (0x06) 09:41:52.465 SERIAL « 0x0104011301e8 (6 bytes) 09:41:52.466 SERIAL » [ACK] (0x06) 09:41:52.466 DRIVER « [RES] [SendData] was sent: true 09:41:52.504 SERIAL « 0x010700136800000586 (9 bytes) 09:41:52.504 SERIAL » [ACK] (0x06) 09:41:52.505 DRIVER « [REQ] [SendData] callback id: 104 transmit status: OK 09:41:52.553 SERIAL « 0x010b00040020057006040102a4 (13 bytes) 09:41:52.558 CNTRLR [Node 032] [~] [Configuration] 4: 2 => 2 09:41:52.561 SERIAL » [ACK] (0x06) 09:41:52.562 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 1 value: 2 09:41:52.566 SERIAL » 0x010b0013110431040308256980 (13 bytes) 09:41:52.566 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 105 └─[MultilevelSensorCCGet] sensor type: Illuminance scale: Lux 09:41:52.567 CNTRLR « [Node 032] parameter #4 has value: 2 09:41:52.567 CNTRLR » [Node 032] querying parameter #6 value... 09:41:52.571 SERIAL « [ACK] (0x06) 09:41:52.577 SERIAL « 0x0104011301e8 (6 bytes) 09:41:52.577 SERIAL » [ACK] (0x06) 09:41:52.578 DRIVER « [RES] [SendData] was sent: true 09:41:52.639 SERIAL « 0x010700136900000785 (9 bytes) 09:41:52.640 SERIAL » [ACK] (0x06) 09:41:52.640 DRIVER « [REQ] [SendData] callback id: 105 transmit status: OK 09:41:52.650 SERIAL « 0x010c00040011063105030a001fc2 (14 bytes) 09:41:52.651 CNTRLR [Node 017] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 09:41:52.651 CNTRLR [Node 017] [~] [Multilevel Sensor] Illuminance: 12 => 31 [Endpoint 0] 09:41:52.652 SERIAL » [ACK] (0x06) 09:41:52.653 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 31 09:41:52.663 SERIAL » 0x010a00132003700506256af9 (12 bytes) 09:41:52.663 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 106 └─[ConfigurationCCGet] parameter #: 6 09:41:52.664 CNTRLR « [Node 017] received current Illuminance sensor reading: 31 Lux 09:41:52.664 CNTRLR [Node 017] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 09:41:52.693 SERIAL « [ACK] (0x06) 09:41:52.697 SERIAL « 0x0104011301e8 (6 bytes) 09:41:52.697 SERIAL » [ACK] (0x06) 09:41:52.701 DRIVER « [RES] [SendData] was sent: true 09:41:52.704 CNTRLR [Node 017] ConfigurationCC: Loading configuration parameters from device confi g 09:41:52.711 CNTRLR [Node 017] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:41:52.712 CNTRLR [Node 017] [Configuration] 1: metadata updated 09:41:52.714 CNTRLR [Node 017] [Configuration] 2: metadata updated 09:41:52.715 CNTRLR [Node 017] [Configuration] 3: metadata updated 09:41:52.716 CNTRLR [Node 017] [Configuration] 4: metadata updated 09:41:52.717 CNTRLR [Node 017] [Configuration] 6: metadata updated 09:41:52.719 CNTRLR [Node 017] [Configuration] 8: metadata updated 09:41:52.720 CNTRLR [Node 017] [Configuration] 9: metadata updated 09:41:52.722 CNTRLR [Node 017] [Configuration] 12: metadata updated 09:41:52.723 CNTRLR [Node 017] [Configuration] 14: metadata updated 09:41:52.725 CNTRLR [Node 017] [Configuration] 16: metadata updated 09:41:52.726 CNTRLR [Node 017] [Configuration] 20: metadata updated 09:41:52.727 CNTRLR [Node 017] [Configuration] 22: metadata updated 09:41:52.728 CNTRLR [Node 017] [Configuration] 24: metadata updated 09:41:52.729 CNTRLR [Node 017] [Configuration] 26: metadata updated 09:41:52.731 CNTRLR [Node 017] [Configuration] 40: metadata updated 09:41:52.732 CNTRLR [Node 017] [Configuration] 42: metadata updated 09:41:52.733 CNTRLR [Node 017] [Configuration] 60: metadata updated 09:41:52.734 CNTRLR [Node 017] [Configuration] 62: metadata updated 09:41:52.736 CNTRLR [Node 017] [Configuration] 64: metadata updated 09:41:52.737 CNTRLR [Node 017] [Configuration] 66: metadata updated 09:41:52.739 CNTRLR [Node 017] [Configuration] 80: metadata updated 09:41:52.740 CNTRLR [Node 017] [Configuration] 81: metadata updated 09:41:52.741 CNTRLR [Node 017] [Configuration] 82: metadata updated 09:41:52.742 CNTRLR [Node 017] [Configuration] 83: metadata updated 09:41:52.743 CNTRLR [Node 017] [Configuration] 86: metadata updated 09:41:52.745 CNTRLR [Node 017] [Configuration] 87: metadata updated 09:41:52.746 CNTRLR [Node 017] [Configuration] 89: metadata updated 09:41:52.747 CNTRLR [Node 017] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:41:52.747 CNTRLR » [Node 017] querying parameter #1 value... 09:41:52.754 SERIAL « 0x010700136a00000485 (9 bytes) 09:41:52.755 SERIAL » [ACK] (0x06) 09:41:52.766 DRIVER « [REQ] [SendData] callback id: 106 transmit status: OK 09:41:52.799 SERIAL « 0x010c000400200670060602001ebd (14 bytes) 09:41:52.805 CNTRLR [Node 032] [~] [Configuration] 6: 30 => 30 09:41:52.806 SERIAL » [ACK] (0x06) 09:41:52.823 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 2 value: 30 09:41:52.826 SERIAL » 0x010a00131103700501256bce (12 bytes) 09:41:52.827 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 107 └─[ConfigurationCCGet] parameter #: 1 09:41:52.828 CNTRLR « [Node 032] parameter #6 has value: 30 09:41:52.828 CNTRLR » [Node 032] querying parameter #8 value... 09:41:52.842 SERIAL « [ACK] (0x06) 09:41:52.846 SERIAL « 0x0104011301e8 (6 bytes) 09:41:52.847 SERIAL » [ACK] (0x06) 09:41:52.848 DRIVER « [RES] [SendData] was sent: true 09:41:52.853 SERIAL « 0x010700136b00000383 (9 bytes) 09:41:52.854 SERIAL » [ACK] (0x06) 09:41:52.854 DRIVER « [REQ] [SendData] callback id: 107 transmit status: OK 09:41:52.864 SERIAL « 0x010b0004001105700601010a98 (13 bytes) 09:41:52.869 CNTRLR [Node 017] [~] [Configuration] 1: 10 => 10 09:41:52.870 SERIAL » [ACK] (0x06) 09:41:52.871 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 10 09:41:52.877 SERIAL » 0x010a00132003700508256cf1 (12 bytes) 09:41:52.877 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 108 └─[ConfigurationCCGet] parameter #: 8 09:41:52.878 CNTRLR « [Node 017] parameter #1 has value: 10 09:41:52.878 CNTRLR » [Node 017] querying parameter #2 value... 09:41:52.885 SERIAL « [ACK] (0x06) 09:41:52.888 SERIAL « 0x0104011301e8 (6 bytes) 09:41:52.888 SERIAL » [ACK] (0x06) 09:41:52.890 DRIVER « [RES] [SendData] was sent: true 09:41:52.924 SERIAL « 0x010700136c00000582 (9 bytes) 09:41:52.925 SERIAL » [ACK] (0x06) 09:41:52.925 DRIVER « [REQ] [SendData] callback id: 108 transmit status: OK 09:41:52.971 SERIAL « 0x010b00040020057006080100aa (13 bytes) 09:41:52.979 CNTRLR [Node 032] [~] [Configuration] 8: 0 => 0 09:41:52.980 SERIAL » [ACK] (0x06) 09:41:52.981 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 0 09:41:52.986 SERIAL » 0x010a00131103700502256dcb (12 bytes) 09:41:52.987 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 109 └─[ConfigurationCCGet] parameter #: 2 09:41:52.988 CNTRLR « [Node 032] parameter #8 has value: 0 09:41:52.988 CNTRLR » [Node 032] querying parameter #9 value... 09:41:52.993 SERIAL « [ACK] (0x06) 09:41:52.996 SERIAL « 0x0104011301e8 (6 bytes) 09:41:52.996 SERIAL » [ACK] (0x06) 09:41:52.997 DRIVER « [RES] [SendData] was sent: true 09:41:53.059 SERIAL « 0x010700136d00000781 (9 bytes) 09:41:53.059 SERIAL » [ACK] (0x06) 09:41:53.060 DRIVER « [REQ] [SendData] callback id: 109 transmit status: OK 09:41:53.069 SERIAL « 0x010b0004001105700602010f9e (13 bytes) 09:41:53.077 CNTRLR [Node 017] [~] [Configuration] 2: 15 => 15 09:41:53.078 SERIAL » [ACK] (0x06) 09:41:53.079 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 15 09:41:53.090 SERIAL » 0x010a00132003700509256ef2 (12 bytes) 09:41:53.090 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 110 └─[ConfigurationCCGet] parameter #: 9 09:41:53.092 CNTRLR « [Node 017] parameter #2 has value: 15 09:41:53.092 CNTRLR » [Node 017] querying parameter #3 value... 09:41:53.098 SERIAL « [ACK] (0x06) 09:41:53.101 SERIAL « 0x0104011301e8 (6 bytes) 09:41:53.101 SERIAL » [ACK] (0x06) 09:41:53.103 DRIVER « [RES] [SendData] was sent: true 09:41:53.137 SERIAL « 0x010700136e00000481 (9 bytes) 09:41:53.138 SERIAL » [ACK] (0x06) 09:41:53.139 DRIVER « [REQ] [SendData] callback id: 110 transmit status: OK 09:41:53.186 SERIAL « 0x010c000400200670060902002884 (14 bytes) 09:41:53.196 CNTRLR [Node 032] [~] [Configuration] 9: 40 => 40 09:41:53.197 SERIAL » [ACK] (0x06) 09:41:53.199 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 2 value: 40 09:41:53.205 SERIAL » 0x010a00131103700503256fc8 (12 bytes) 09:41:53.205 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 111 └─[ConfigurationCCGet] parameter #: 3 09:41:53.207 CNTRLR « [Node 032] parameter #9 has value: 40 09:41:53.207 CNTRLR » [Node 032] querying parameter #12 value... 09:41:53.215 SERIAL « [ACK] (0x06) 09:41:53.217 SERIAL « 0x0104011301e8 (6 bytes) 09:41:53.218 SERIAL » [ACK] (0x06) 09:41:53.220 DRIVER « [RES] [SendData] was sent: true 09:41:53.269 SERIAL « 0x010700136f00000682 (9 bytes) 09:41:53.269 SERIAL » [ACK] (0x06) 09:41:53.271 DRIVER « [REQ] [SendData] callback id: 111 transmit status: OK 09:41:53.284 SERIAL « 0x010b0004001105700603010191 (13 bytes) 09:41:53.289 CNTRLR [Node 017] [~] [Configuration] 3: 1 => 1 09:41:53.290 SERIAL » [ACK] (0x06) 09:41:53.292 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 1 09:41:53.297 SERIAL » 0x010a0013200370050c2570e9 (12 bytes) 09:41:53.297 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 112 └─[ConfigurationCCGet] parameter #: 12 09:41:53.298 CNTRLR « [Node 017] parameter #3 has value: 1 09:41:53.298 CNTRLR » [Node 017] querying parameter #4 value... 09:41:53.301 SERIAL « [ACK] (0x06) 09:41:53.307 SERIAL « 0x0104011301e8 (6 bytes) 09:41:53.307 SERIAL » [ACK] (0x06) 09:41:53.308 DRIVER « [RES] [SendData] was sent: true 09:41:53.344 SERIAL « 0x01070013700000059e (9 bytes) 09:41:53.344 SERIAL » [ACK] (0x06) 09:41:53.345 DRIVER « [REQ] [SendData] callback id: 112 transmit status: OK 09:41:53.391 SERIAL « 0x010b000400200570060c0100ae (13 bytes) 09:41:53.396 CNTRLR [Node 032] [~] [Configuration] 12: 0 => 0 09:41:53.397 SERIAL » [ACK] (0x06) 09:41:53.398 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 1 value: 0 09:41:53.401 SERIAL » 0x010a001311037005042571d1 (12 bytes) 09:41:53.401 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 113 └─[ConfigurationCCGet] parameter #: 4 09:41:53.402 CNTRLR « [Node 032] parameter #12 has value: 0 09:41:53.402 CNTRLR » [Node 032] querying parameter #14 value... 09:41:53.406 SERIAL « [ACK] (0x06) 09:41:53.411 SERIAL « 0x0104011301e8 (6 bytes) 09:41:53.411 SERIAL » [ACK] (0x06) 09:41:53.412 DRIVER « [RES] [SendData] was sent: true 09:41:53.479 SERIAL « 0x01070013710000079d (9 bytes) 09:41:53.479 SERIAL » [ACK] (0x06) 09:41:53.480 DRIVER « [REQ] [SendData] callback id: 113 transmit status: OK 09:41:53.490 SERIAL « 0x010b0004001105700604010295 (13 bytes) 09:41:53.495 CNTRLR [Node 017] [~] [Configuration] 4: 2 => 2 09:41:53.495 SERIAL » [ACK] (0x06) 09:41:53.496 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 1 value: 2 09:41:53.499 SERIAL » 0x010a0013200370050e2572e9 (12 bytes) 09:41:53.500 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 114 └─[ConfigurationCCGet] parameter #: 14 09:41:53.501 CNTRLR « [Node 017] parameter #4 has value: 2 09:41:53.501 CNTRLR » [Node 017] querying parameter #6 value... 09:41:53.504 SERIAL « [ACK] (0x06) 09:41:53.509 SERIAL « 0x0104011301e8 (6 bytes) 09:41:53.510 SERIAL » [ACK] (0x06) 09:41:53.511 DRIVER « [RES] [SendData] was sent: true 09:41:53.546 SERIAL « 0x01070013720000049d (9 bytes) 09:41:53.547 SERIAL » [ACK] (0x06) 09:41:53.547 DRIVER « [REQ] [SendData] callback id: 114 transmit status: OK 09:41:53.595 SERIAL « 0x010b000400200570060e01ff53 (13 bytes) 09:41:53.600 CNTRLR [Node 032] [~] [Configuration] 14: 255 => 255 09:41:53.601 SERIAL » [ACK] (0x06) 09:41:53.602 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 255 09:41:53.605 SERIAL » 0x010a001311037005062573d1 (12 bytes) 09:41:53.605 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 115 └─[ConfigurationCCGet] parameter #: 6 09:41:53.606 CNTRLR « [Node 032] parameter #14 has value: 255 09:41:53.606 CNTRLR » [Node 032] querying parameter #16 value... 09:41:53.610 SERIAL « [ACK] (0x06) 09:41:53.615 SERIAL « 0x0104011301e8 (6 bytes) 09:41:53.615 SERIAL » [ACK] (0x06) 09:41:53.616 DRIVER « [RES] [SendData] was sent: true 09:41:53.679 SERIAL « 0x01070013730000079f (9 bytes) 09:41:53.679 SERIAL » [ACK] (0x06) 09:41:53.680 DRIVER « [REQ] [SendData] callback id: 115 transmit status: OK 09:41:53.777 SERIAL « 0x010c000400110670060602001e8c (14 bytes) 09:41:53.782 CNTRLR [Node 017] [~] [Configuration] 6: 30 => 30 09:41:53.783 SERIAL » [ACK] (0x06) 09:41:53.784 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 2 value: 30 09:41:53.787 SERIAL » 0x010a001320037005102574f1 (12 bytes) 09:41:53.787 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 116 └─[ConfigurationCCGet] parameter #: 16 09:41:53.788 CNTRLR « [Node 017] parameter #6 has value: 30 09:41:53.788 CNTRLR » [Node 017] querying parameter #8 value... 09:41:53.792 SERIAL « [ACK] (0x06) 09:41:53.797 SERIAL « 0x0104011301e8 (6 bytes) 09:41:53.797 SERIAL » [ACK] (0x06) 09:41:53.798 DRIVER « [RES] [SendData] was sent: true 09:41:53.834 SERIAL « 0x01070013740000059a (9 bytes) 09:41:53.834 SERIAL » [ACK] (0x06) 09:41:53.835 DRIVER « [REQ] [SendData] callback id: 116 transmit status: OK 09:41:53.881 SERIAL « 0x010b00040020057006100100b2 (13 bytes) 09:41:53.890 CNTRLR [Node 032] [~] [Configuration] 16: 0 => 0 09:41:53.891 SERIAL » [ACK] (0x06) 09:41:53.892 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 0 09:41:53.904 SERIAL » 0x010a001311037005082575d9 (12 bytes) 09:41:53.904 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 117 └─[ConfigurationCCGet] parameter #: 8 09:41:53.905 CNTRLR « [Node 032] parameter #16 has value: 0 09:41:53.906 CNTRLR » [Node 032] querying parameter #20 value... 09:41:53.910 SERIAL « [ACK] (0x06) 09:41:53.913 SERIAL « 0x0104011301e8 (6 bytes) 09:41:53.913 SERIAL » [ACK] (0x06) 09:41:53.914 DRIVER « [RES] [SendData] was sent: true 09:41:53.969 SERIAL « 0x010700137500000698 (9 bytes) 09:41:53.970 SERIAL » [ACK] (0x06) 09:41:53.970 DRIVER « [REQ] [SendData] callback id: 117 transmit status: OK 09:41:53.980 SERIAL « 0x010b000400110570060801009b (13 bytes) 09:41:53.985 CNTRLR [Node 017] [~] [Configuration] 8: 0 => 0 09:41:53.986 SERIAL » [ACK] (0x06) 09:41:53.987 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 0 09:41:53.991 SERIAL » 0x010a001320037005142576f7 (12 bytes) 09:41:53.991 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 118 └─[ConfigurationCCGet] parameter #: 20 09:41:53.992 CNTRLR « [Node 017] parameter #8 has value: 0 09:41:53.993 CNTRLR » [Node 017] querying parameter #9 value... 09:41:54.000 SERIAL « [ACK] (0x06) 09:41:54.003 SERIAL « 0x0104011301e8 (6 bytes) 09:41:54.004 SERIAL » [ACK] (0x06) 09:41:54.005 DRIVER « [RES] [SendData] was sent: true 09:41:54.040 SERIAL « 0x010700137600000499 (9 bytes) 09:41:54.040 SERIAL » [ACK] (0x06) 09:41:54.041 DRIVER « [REQ] [SendData] callback id: 118 transmit status: OK 09:41:54.087 SERIAL « 0x010b0004002005700614010fb9 (13 bytes) 09:41:54.096 CNTRLR [Node 032] [~] [Configuration] 20: 15 => 15 09:41:54.097 SERIAL » [ACK] (0x06) 09:41:54.099 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 15 09:41:54.103 SERIAL » 0x010a001311037005092577da (12 bytes) 09:41:54.103 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 119 └─[ConfigurationCCGet] parameter #: 9 09:41:54.104 CNTRLR « [Node 032] parameter #20 has value: 15 09:41:54.104 CNTRLR » [Node 032] querying parameter #22 value... 09:41:54.109 SERIAL « [ACK] (0x06) 09:41:54.112 SERIAL « 0x0104011301e8 (6 bytes) 09:41:54.112 SERIAL » [ACK] (0x06) 09:41:54.114 DRIVER « [RES] [SendData] was sent: true 09:41:54.169 SERIAL « 0x01070013770000069a (9 bytes) 09:41:54.169 SERIAL » [ACK] (0x06) 09:41:54.170 DRIVER « [REQ] [SendData] callback id: 119 transmit status: OK 09:41:54.180 SERIAL « 0x010c0004001106700609020028b5 (14 bytes) 09:41:54.187 CNTRLR [Node 017] [~] [Configuration] 9: 40 => 40 09:41:54.188 SERIAL » [ACK] (0x06) 09:41:54.189 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 2 value: 40 09:41:54.194 SERIAL » 0x010a001320037005162578fb (12 bytes) 09:41:54.194 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 120 └─[ConfigurationCCGet] parameter #: 22 09:41:54.196 CNTRLR « [Node 017] parameter #9 has value: 40 09:41:54.196 CNTRLR » [Node 017] querying parameter #12 value... 09:41:54.203 SERIAL « [ACK] (0x06) 09:41:54.206 SERIAL « 0x0104011301e8 (6 bytes) 09:41:54.206 SERIAL » [ACK] (0x06) 09:41:54.209 DRIVER « [RES] [SendData] was sent: true 09:41:54.242 SERIAL « 0x010700137800000497 (9 bytes) 09:41:54.242 SERIAL » [ACK] (0x06) 09:41:54.243 DRIVER « [REQ] [SendData] callback id: 120 transmit status: OK 09:41:54.290 SERIAL « 0x010c000400200670061602001ead (14 bytes) 09:41:54.300 CNTRLR [Node 032] [~] [Configuration] 22: 30 => 30 09:41:54.301 SERIAL » [ACK] (0x06) 09:41:54.302 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 30 09:41:54.308 SERIAL » 0x010a0013110370050c2579d1 (12 bytes) 09:41:54.308 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 121 └─[ConfigurationCCGet] parameter #: 12 09:41:54.309 CNTRLR « [Node 032] parameter #22 has value: 30 09:41:54.310 CNTRLR » [Node 032] querying parameter #24 value... 09:41:54.315 SERIAL « [ACK] (0x06) 09:41:54.318 SERIAL « 0x0104011301e8 (6 bytes) 09:41:54.318 SERIAL » [ACK] (0x06) 09:41:54.319 DRIVER « [RES] [SendData] was sent: true 09:41:54.379 SERIAL « 0x010700137900000795 (9 bytes) 09:41:54.379 SERIAL » [ACK] (0x06) 09:41:54.380 DRIVER « [REQ] [SendData] callback id: 121 transmit status: OK 09:41:54.390 SERIAL « 0x010b000400110570060c01009f (13 bytes) 09:41:54.397 CNTRLR [Node 017] [~] [Configuration] 12: 0 => 0 09:41:54.398 SERIAL » [ACK] (0x06) 09:41:54.399 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 1 value: 0 09:41:54.437 SERIAL » 0x010a00132003700518257af7 (12 bytes) 09:41:54.438 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 122 └─[ConfigurationCCGet] parameter #: 24 09:41:54.439 CNTRLR « [Node 017] parameter #12 has value: 0 09:41:54.440 CNTRLR » [Node 017] querying parameter #14 value... 09:41:54.446 SERIAL « [ACK] (0x06) 09:41:54.448 SERIAL « 0x0104011301e8 (6 bytes) 09:41:54.449 SERIAL » [ACK] (0x06) 09:41:54.450 DRIVER « [RES] [SendData] was sent: true 09:41:54.485 SERIAL « 0x010700137a00000594 (9 bytes) 09:41:54.486 SERIAL » [ACK] (0x06) 09:41:54.487 DRIVER « [REQ] [SendData] callback id: 122 transmit status: OK 09:41:54.534 SERIAL « 0x010b00040020057006180100ba (13 bytes) 09:41:54.539 CNTRLR [Node 032] [~] [Configuration] 24: 0 => 0 09:41:54.539 SERIAL » [ACK] (0x06) 09:41:54.540 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 24 value size: 1 value: 0 09:41:54.543 SERIAL » 0x010a0013110370050e257bd1 (12 bytes) 09:41:54.544 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 123 └─[ConfigurationCCGet] parameter #: 14 09:41:54.544 CNTRLR « [Node 032] parameter #24 has value: 0 09:41:54.545 CNTRLR » [Node 032] querying parameter #26 value... 09:41:54.548 SERIAL « [ACK] (0x06) 09:41:54.554 SERIAL « 0x0104011301e8 (6 bytes) 09:41:54.555 SERIAL » [ACK] (0x06) 09:41:54.555 DRIVER « [RES] [SendData] was sent: true 09:41:54.619 SERIAL « 0x010700137b00000797 (9 bytes) 09:41:54.619 SERIAL » [ACK] (0x06) 09:41:54.620 DRIVER « [REQ] [SendData] callback id: 123 transmit status: OK 09:41:54.630 SERIAL « 0x010b000400110570060e01ff62 (13 bytes) 09:41:54.635 CNTRLR [Node 017] [~] [Configuration] 14: 255 => 255 09:41:54.636 SERIAL » [ACK] (0x06) 09:41:54.637 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 255 09:41:54.640 SERIAL » 0x010a0013200370051a257cf3 (12 bytes) 09:41:54.640 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 124 └─[ConfigurationCCGet] parameter #: 26 09:41:54.641 CNTRLR « [Node 017] parameter #14 has value: 255 09:41:54.641 CNTRLR » [Node 017] querying parameter #16 value... 09:41:54.644 SERIAL « [ACK] (0x06) 09:41:54.650 SERIAL « 0x0104011301e8 (6 bytes) 09:41:54.650 SERIAL » [ACK] (0x06) 09:41:54.651 DRIVER « [RES] [SendData] was sent: true 09:41:54.687 SERIAL « 0x010700137c00000493 (9 bytes) 09:41:54.687 SERIAL » [ACK] (0x06) 09:41:54.687 DRIVER « [REQ] [SendData] callback id: 124 transmit status: OK 09:41:54.735 SERIAL « 0x010b000400200570061a0100b8 (13 bytes) 09:41:54.740 CNTRLR [Node 032] [~] [Configuration] 26: 0 => 0 09:41:54.741 SERIAL » [ACK] (0x06) 09:41:54.742 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 26 value size: 1 value: 0 09:41:54.745 SERIAL » 0x010a00131103700510257dc9 (12 bytes) 09:41:54.745 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 125 └─[ConfigurationCCGet] parameter #: 16 09:41:54.746 CNTRLR « [Node 032] parameter #26 has value: 0 09:41:54.746 CNTRLR » [Node 032] querying parameter #40 value... 09:41:54.749 SERIAL « [ACK] (0x06) 09:41:54.755 SERIAL « 0x0104011301e8 (6 bytes) 09:41:54.755 SERIAL » [ACK] (0x06) 09:41:54.756 DRIVER « [RES] [SendData] was sent: true 09:41:54.829 SERIAL « 0x010700137d0000089e (9 bytes) 09:41:54.829 SERIAL » [ACK] (0x06) 09:41:54.829 DRIVER « [REQ] [SendData] callback id: 125 transmit status: OK 09:41:54.840 SERIAL « 0x010b0004001105700610010083 (13 bytes) 09:41:54.845 CNTRLR [Node 017] [~] [Configuration] 16: 0 => 0 09:41:54.845 SERIAL » [ACK] (0x06) 09:41:54.846 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 0 09:41:54.849 SERIAL » 0x010a00132003700528257ec3 (12 bytes) 09:41:54.849 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 126 └─[ConfigurationCCGet] parameter #: 40 09:41:54.850 CNTRLR « [Node 017] parameter #16 has value: 0 09:41:54.850 CNTRLR » [Node 017] querying parameter #20 value... 09:41:54.854 SERIAL « [ACK] (0x06) 09:41:54.863 SERIAL « 0x0104011301e8 (6 bytes) 09:41:54.864 SERIAL » [ACK] (0x06) 09:41:54.864 DRIVER « [RES] [SendData] was sent: true 09:41:54.896 SERIAL « 0x010700137e00000491 (9 bytes) 09:41:54.896 SERIAL » [ACK] (0x06) 09:41:54.897 DRIVER « [REQ] [SendData] callback id: 126 transmit status: OK 09:41:54.944 SERIAL « 0x010c00040020067006280200c845 (14 bytes) 09:41:54.949 CNTRLR [Node 032] [~] [Configuration] 40: 200 => 200 09:41:54.949 SERIAL » [ACK] (0x06) 09:41:54.950 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 2 value: 200 09:41:54.953 SERIAL » 0x010a00131103700514257fcf (12 bytes) 09:41:54.953 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 127 └─[ConfigurationCCGet] parameter #: 20 09:41:54.959 CNTRLR « [Node 032] parameter #40 has value: 200 09:41:54.959 CNTRLR » [Node 032] querying parameter #42 value... 09:41:54.963 SERIAL « [ACK] (0x06) 09:41:54.966 SERIAL « 0x0104011301e8 (6 bytes) 09:41:54.967 SERIAL » [ACK] (0x06) 09:41:54.967 DRIVER « [RES] [SendData] was sent: true 09:41:55.029 SERIAL « 0x010700137f00000793 (9 bytes) 09:41:55.029 SERIAL » [ACK] (0x06) 09:41:55.029 DRIVER « [REQ] [SendData] callback id: 127 transmit status: OK 09:41:55.040 SERIAL « 0x010b0004001105700614010f88 (13 bytes) 09:41:55.044 CNTRLR [Node 017] [~] [Configuration] 20: 15 => 15 09:41:55.045 SERIAL » [ACK] (0x06) 09:41:55.046 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 15 09:41:55.049 SERIAL » 0x010a0013200370052a25803f (12 bytes) 09:41:55.049 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 128 └─[ConfigurationCCGet] parameter #: 42 09:41:55.050 CNTRLR « [Node 017] parameter #20 has value: 15 09:41:55.050 CNTRLR » [Node 017] querying parameter #22 value... 09:41:55.054 SERIAL « [ACK] (0x06) 09:41:55.059 SERIAL « 0x0104011301e8 (6 bytes) 09:41:55.060 SERIAL » [ACK] (0x06) 09:41:55.061 DRIVER « [RES] [SendData] was sent: true 09:41:55.096 SERIAL « 0x01070013800000046f (9 bytes) 09:41:55.096 SERIAL » [ACK] (0x06) 09:41:55.097 DRIVER « [REQ] [SendData] callback id: 128 transmit status: OK 09:41:55.144 SERIAL « 0x010c000400200670062a0200008f (14 bytes) 09:41:55.149 CNTRLR [Node 032] [~] [Configuration] 42: 0 => 0 09:41:55.150 SERIAL » [ACK] (0x06) 09:41:55.150 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 0 09:41:55.153 SERIAL » 0x010a00131103700516258133 (12 bytes) 09:41:55.154 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 129 └─[ConfigurationCCGet] parameter #: 22 09:41:55.154 CNTRLR « [Node 032] parameter #42 has value: 0 09:41:55.155 CNTRLR » [Node 032] querying parameter #60 value... 09:41:55.165 SERIAL « [ACK] (0x06) 09:41:55.167 SERIAL « 0x0104011301e8 (6 bytes) 09:41:55.167 SERIAL » [ACK] (0x06) 09:41:55.169 DRIVER « [RES] [SendData] was sent: true 09:41:55.229 SERIAL « 0x01070013810000076d (9 bytes) 09:41:55.230 SERIAL » [ACK] (0x06) 09:41:55.232 DRIVER « [REQ] [SendData] callback id: 129 transmit status: OK 09:41:55.240 SERIAL « 0x010c000400110670061602001e9c (14 bytes) 09:41:55.252 CNTRLR [Node 017] [~] [Configuration] 22: 30 => 30 09:41:55.262 SERIAL » [ACK] (0x06) 09:41:55.264 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 30 09:41:55.269 SERIAL » 0x010a0013200370053c25822b (12 bytes) 09:41:55.270 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 130 └─[ConfigurationCCGet] parameter #: 60 09:41:55.271 CNTRLR « [Node 017] parameter #22 has value: 30 09:41:55.271 CNTRLR » [Node 017] querying parameter #24 value... 09:41:55.278 SERIAL « [ACK] (0x06) 09:41:55.282 SERIAL « 0x0104011301e8 (6 bytes) 09:41:55.282 SERIAL » [ACK] (0x06) 09:41:55.288 DRIVER « [RES] [SendData] was sent: true 09:41:55.317 SERIAL « 0x01070013820000046d (9 bytes) 09:41:55.318 SERIAL » [ACK] (0x06) 09:41:55.318 DRIVER « [REQ] [SendData] callback id: 130 transmit status: OK 09:41:55.365 SERIAL « 0x010b000400200570063c010a94 (13 bytes) 09:41:55.370 CNTRLR [Node 032] [~] [Configuration] 60: 10 => 10 09:41:55.371 SERIAL » [ACK] (0x06) 09:41:55.372 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 1 value: 10 09:41:55.375 SERIAL » 0x010a0013110370051825833f (12 bytes) 09:41:55.375 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 131 └─[ConfigurationCCGet] parameter #: 24 09:41:55.376 CNTRLR « [Node 032] parameter #60 has value: 10 09:41:55.376 CNTRLR » [Node 032] querying parameter #62 value... 09:41:55.379 SERIAL « [ACK] (0x06) 09:41:55.385 SERIAL « 0x0104011301e8 (6 bytes) 09:41:55.386 SERIAL » [ACK] (0x06) 09:41:55.386 DRIVER « [RES] [SendData] was sent: true 09:41:55.449 SERIAL « 0x01070013830000076f (9 bytes) 09:41:55.449 SERIAL » [ACK] (0x06) 09:41:55.450 DRIVER « [REQ] [SendData] callback id: 131 transmit status: OK 09:41:55.460 SERIAL « 0x010b000400110570061801008b (13 bytes) 09:41:55.465 CNTRLR [Node 017] [~] [Configuration] 24: 0 => 0 09:41:55.466 SERIAL » [ACK] (0x06) 09:41:55.466 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 24 value size: 1 value: 0 09:41:55.469 SERIAL » 0x010a0013200370053e25842f (12 bytes) 09:41:55.470 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 132 └─[ConfigurationCCGet] parameter #: 62 09:41:55.470 CNTRLR « [Node 017] parameter #24 has value: 0 09:41:55.471 CNTRLR » [Node 017] querying parameter #26 value... 09:41:55.474 SERIAL « [ACK] (0x06) 09:41:55.483 SERIAL « 0x0104011301e8 (6 bytes) 09:41:55.484 SERIAL » [ACK] (0x06) 09:41:55.485 DRIVER « [RES] [SendData] was sent: true 09:41:55.520 SERIAL « 0x01070013840000046b (9 bytes) 09:41:55.520 SERIAL » [ACK] (0x06) 09:41:55.521 DRIVER « [REQ] [SendData] callback id: 132 transmit status: OK 09:41:55.568 SERIAL « 0x010c000400200670063e0203841c (14 bytes) 09:41:55.573 CNTRLR [Node 032] [~] [Configuration] 62: 900 => 900 09:41:55.574 SERIAL » [ACK] (0x06) 09:41:55.574 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 62 value size: 2 value: 900 09:41:55.577 SERIAL » 0x010a0013110370051a25853b (12 bytes) 09:41:55.578 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 133 └─[ConfigurationCCGet] parameter #: 26 09:41:55.578 CNTRLR « [Node 032] parameter #62 has value: 900 09:41:55.579 CNTRLR » [Node 032] querying parameter #64 value... 09:41:55.582 SERIAL « [ACK] (0x06) 09:41:55.589 SERIAL « 0x0104011301e8 (6 bytes) 09:41:55.589 SERIAL » [ACK] (0x06) 09:41:55.590 DRIVER « [RES] [SendData] was sent: true 09:41:55.649 SERIAL « 0x010700138500000769 (9 bytes) 09:41:55.649 SERIAL » [ACK] (0x06) 09:41:55.650 DRIVER « [REQ] [SendData] callback id: 133 transmit status: OK 09:41:55.661 SERIAL « 0x010b000400110570061a010089 (13 bytes) 09:41:55.666 CNTRLR [Node 017] [~] [Configuration] 26: 0 => 0 09:41:55.667 SERIAL » [ACK] (0x06) 09:41:55.668 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 26 value size: 1 value: 0 09:41:55.671 SERIAL » 0x010a00132003700540258653 (12 bytes) 09:41:55.672 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 134 └─[ConfigurationCCGet] parameter #: 64 09:41:55.673 CNTRLR « [Node 017] parameter #26 has value: 0 09:41:55.673 CNTRLR » [Node 017] querying parameter #40 value... 09:41:55.676 SERIAL « [ACK] (0x06) 09:41:55.692 SERIAL « 0x0104011301e8 (6 bytes) 09:41:55.693 SERIAL » [ACK] (0x06) 09:41:55.694 DRIVER « [RES] [SendData] was sent: true 09:41:55.719 SERIAL « 0x010700138600000469 (9 bytes) 09:41:55.719 SERIAL » [ACK] (0x06) 09:41:55.719 DRIVER « [REQ] [SendData] callback id: 134 transmit status: OK 09:41:55.768 SERIAL « 0x010c0004002006700640020000e5 (14 bytes) 09:41:55.773 CNTRLR [Node 032] [~] [Configuration] 64: 0 => 0 09:41:55.774 SERIAL » [ACK] (0x06) 09:41:55.775 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 64 value size: 2 value: 0 09:41:55.778 SERIAL » 0x010a0013110370052825870b (12 bytes) 09:41:55.778 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 135 └─[ConfigurationCCGet] parameter #: 40 09:41:55.779 CNTRLR « [Node 032] parameter #64 has value: 0 09:41:55.779 CNTRLR » [Node 032] querying parameter #66 value... 09:41:55.783 SERIAL « [ACK] (0x06) 09:41:55.788 SERIAL « 0x0104011301e8 (6 bytes) 09:41:55.788 SERIAL » [ACK] (0x06) 09:41:55.790 DRIVER « [RES] [SendData] was sent: true 09:41:55.859 SERIAL « 0x010c00040011067006280200c874 (14 bytes) 09:41:55.864 CNTRLR [Node 017] [~] [Configuration] 40: 200 => 200 09:41:55.864 SERIAL » [ACK] (0x06) 09:41:55.865 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 2 value: 200 09:41:55.918 SERIAL « 0x010700138700000d61 (9 bytes) 09:41:55.919 SERIAL » [ACK] (0x06) 09:41:55.919 DRIVER « [REQ] [SendData] callback id: 135 transmit status: OK 09:41:55.929 SERIAL « 0x010c00040011067006280200c874 (14 bytes) 09:41:55.934 CNTRLR [Node 017] [~] [Configuration] 40: 200 => 200 09:41:55.935 SERIAL » [ACK] (0x06) 09:41:55.936 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 2 value: 200 09:41:55.939 SERIAL » 0x010a0013200370054225885f (12 bytes) 09:41:55.939 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 136 └─[ConfigurationCCGet] parameter #: 66 09:41:55.940 CNTRLR « [Node 017] parameter #40 has value: 200 09:41:55.940 CNTRLR » [Node 017] querying parameter #42 value... 09:41:55.943 SERIAL « [ACK] (0x06) 09:41:55.948 SERIAL « 0x0104011301e8 (6 bytes) 09:41:55.949 SERIAL » [ACK] (0x06) 09:41:55.949 DRIVER « [RES] [SendData] was sent: true 09:41:55.986 SERIAL « 0x010700138800000566 (9 bytes) 09:41:55.986 SERIAL » [ACK] (0x06) 09:41:55.986 DRIVER « [REQ] [SendData] callback id: 136 transmit status: OK 09:41:56.034 SERIAL « 0x010c0004002006700642020000e7 (14 bytes) 09:41:56.044 CNTRLR [Node 032] [~] [Configuration] 66: 0 => 0 09:41:56.045 SERIAL » [ACK] (0x06) 09:41:56.046 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 66 value size: 2 value: 0 09:41:56.051 SERIAL » 0x010a0013110370052a258907 (12 bytes) 09:41:56.052 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 137 └─[ConfigurationCCGet] parameter #: 42 09:41:56.059 CNTRLR « [Node 032] parameter #66 has value: 0 09:41:56.059 CNTRLR » [Node 032] querying parameter #80 value... 09:41:56.075 SERIAL « [ACK] (0x06) 09:41:56.095 SERIAL « 0x0104011301e8 (6 bytes) 09:41:56.095 SERIAL » [ACK] (0x06) 09:41:56.098 DRIVER « [RES] [SendData] was sent: true 09:41:56.125 SERIAL « 0x010700138900000664 (9 bytes) 09:41:56.125 SERIAL » [ACK] (0x06) 09:41:56.126 DRIVER « [REQ] [SendData] callback id: 137 transmit status: OK 09:41:56.130 SERIAL « 0x010c000400110670062a020000be (14 bytes) 09:41:56.136 CNTRLR [Node 017] [~] [Configuration] 42: 0 => 0 09:41:56.137 SERIAL » [ACK] (0x06) 09:41:56.139 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 0 09:41:56.153 SERIAL » 0x010a00132003700550258a4f (12 bytes) 09:41:56.153 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 138 └─[ConfigurationCCGet] parameter #: 80 09:41:56.160 CNTRLR « [Node 017] parameter #42 has value: 0 09:41:56.161 CNTRLR » [Node 017] querying parameter #60 value... 09:41:56.167 SERIAL « [ACK] (0x06) 09:41:56.170 SERIAL « 0x0104011301e8 (6 bytes) 09:41:56.170 SERIAL » [ACK] (0x06) 09:41:56.172 DRIVER « [RES] [SendData] was sent: true 09:41:56.207 SERIAL « 0x010700138a00000465 (9 bytes) 09:41:56.207 SERIAL » [ACK] (0x06) 09:41:56.208 DRIVER « [REQ] [SendData] callback id: 138 transmit status: OK 09:41:56.254 SERIAL « 0x010b00040020057006500100f2 (13 bytes) 09:41:56.259 CNTRLR [Node 032] [~] [Configuration] 80: 0 => 0 09:41:56.260 SERIAL » [ACK] (0x06) 09:41:56.261 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 80 value size: 1 value: 0 09:41:56.266 SERIAL » 0x010a0013110370053c258b13 (12 bytes) 09:41:56.266 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 139 └─[ConfigurationCCGet] parameter #: 60 09:41:56.267 CNTRLR « [Node 032] parameter #80 has value: 0 09:41:56.267 CNTRLR » [Node 032] querying parameter #81 value... 09:41:56.273 SERIAL « [ACK] (0x06) 09:41:56.275 SERIAL « 0x0104011301e8 (6 bytes) 09:41:56.275 SERIAL » [ACK] (0x06) 09:41:56.276 DRIVER « [RES] [SendData] was sent: true 09:41:56.319 SERIAL « 0x010700138b00000565 (9 bytes) 09:41:56.319 SERIAL » [ACK] (0x06) 09:41:56.320 DRIVER « [REQ] [SendData] callback id: 139 transmit status: OK 09:41:56.412 SERIAL « 0x010c0004000306310504220942ab (14 bytes) 09:41:56.414 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:41:56.415 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 116.5 => 237 [Endpoint 0] 09:41:56.415 SERIAL » [ACK] (0x06) 09:41:56.417 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 237 09:41:56.439 SERIAL « 0x010b000400110570063c010aa5 (13 bytes) 09:41:56.445 CNTRLR [Node 017] [~] [Configuration] 60: 10 => 10 09:41:56.446 SERIAL » [ACK] (0x06) 09:41:56.447 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 1 value: 10 09:41:56.451 SERIAL » 0x010a00132003700551258c48 (12 bytes) 09:41:56.451 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 140 └─[ConfigurationCCGet] parameter #: 81 09:41:56.453 CNTRLR « [Node 017] parameter #60 has value: 10 09:41:56.453 CNTRLR » [Node 017] querying parameter #62 value... 09:41:56.456 SERIAL « [ACK] (0x06) 09:41:56.460 SERIAL « 0x0104011301e8 (6 bytes) 09:41:56.461 SERIAL » [ACK] (0x06) 09:41:56.461 DRIVER « [RES] [SendData] was sent: true 09:41:56.499 SERIAL « 0x010700138c00000463 (9 bytes) 09:41:56.499 SERIAL » [ACK] (0x06) 09:41:56.500 DRIVER « [REQ] [SendData] callback id: 140 transmit status: OK 09:41:56.548 SERIAL « 0x010b00040020057006510132c1 (13 bytes) 09:41:56.553 CNTRLR [Node 032] [~] [Configuration] 81: 50 => 50 09:41:56.554 SERIAL » [ACK] (0x06) 09:41:56.555 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 81 value size: 1 value: 50 09:41:56.559 SERIAL » 0x010a0013110370053e258d17 (12 bytes) 09:41:56.559 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 141 └─[ConfigurationCCGet] parameter #: 62 09:41:56.560 CNTRLR « [Node 032] parameter #81 has value: 50 09:41:56.561 CNTRLR » [Node 032] querying parameter #82 value... 09:41:56.564 SERIAL « [ACK] (0x06) 09:41:56.568 SERIAL « 0x0104011301e8 (6 bytes) 09:41:56.569 SERIAL » [ACK] (0x06) 09:41:56.569 DRIVER « [RES] [SendData] was sent: true 09:41:56.629 SERIAL « 0x010700138d00000660 (9 bytes) 09:41:56.629 SERIAL » [ACK] (0x06) 09:41:56.630 DRIVER « [REQ] [SendData] callback id: 141 transmit status: OK 09:41:56.640 SERIAL « 0x010c000400110670063e0203842d (14 bytes) 09:41:56.645 CNTRLR [Node 017] [~] [Configuration] 62: 900 => 900 09:41:56.646 SERIAL » [ACK] (0x06) 09:41:56.647 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 62 value size: 2 value: 900 09:41:56.650 SERIAL » 0x010a00132003700552258e49 (12 bytes) 09:41:56.651 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 142 └─[ConfigurationCCGet] parameter #: 82 09:41:56.652 CNTRLR « [Node 017] parameter #62 has value: 900 09:41:56.652 CNTRLR » [Node 017] querying parameter #64 value... 09:41:56.655 SERIAL « [ACK] (0x06) 09:41:56.659 SERIAL « 0x0104011301e8 (6 bytes) 09:41:56.659 SERIAL » [ACK] (0x06) 09:41:56.660 DRIVER « [RES] [SendData] was sent: true 09:41:56.698 SERIAL « 0x010700138e00000461 (9 bytes) 09:41:56.698 SERIAL » [ACK] (0x06) 09:41:56.698 DRIVER « [REQ] [SendData] callback id: 142 transmit status: OK 09:41:56.746 SERIAL « 0x010c000400200670065202006493 (14 bytes) 09:41:56.751 CNTRLR [Node 032] [~] [Configuration] 82: 100 => 100 09:41:56.752 SERIAL » [ACK] (0x06) 09:41:56.752 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 82 value size: 2 value: 100 09:41:56.756 SERIAL » 0x010a00131103700540258f6b (12 bytes) 09:41:56.756 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 143 └─[ConfigurationCCGet] parameter #: 64 09:41:56.757 CNTRLR « [Node 032] parameter #82 has value: 100 09:41:56.757 CNTRLR » [Node 032] querying parameter #83 value... 09:41:56.760 SERIAL « [ACK] (0x06) 09:41:56.766 SERIAL « 0x0104011301e8 (6 bytes) 09:41:56.766 SERIAL » [ACK] (0x06) 09:41:56.767 DRIVER « [RES] [SendData] was sent: true 09:41:56.829 SERIAL « 0x010700138f00000763 (9 bytes) 09:41:56.829 SERIAL » [ACK] (0x06) 09:41:56.830 DRIVER « [REQ] [SendData] callback id: 143 transmit status: OK 09:41:56.840 SERIAL « 0x010c0004001106700640020000d4 (14 bytes) 09:41:56.845 CNTRLR [Node 017] [~] [Configuration] 64: 0 => 0 09:41:56.846 SERIAL » [ACK] (0x06) 09:41:56.847 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 64 value size: 2 value: 0 09:41:56.851 SERIAL » 0x010a00132003700553259056 (12 bytes) 09:41:56.851 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 144 └─[ConfigurationCCGet] parameter #: 83 09:41:56.852 CNTRLR « [Node 017] parameter #64 has value: 0 09:41:56.852 CNTRLR » [Node 017] querying parameter #66 value... 09:41:56.856 SERIAL « [ACK] (0x06) 09:41:56.860 SERIAL « 0x0104011301e8 (6 bytes) 09:41:56.861 SERIAL » [ACK] (0x06) 09:41:56.862 DRIVER « [RES] [SendData] was sent: true 09:41:56.898 SERIAL « 0x01070013900000047f (9 bytes) 09:41:56.898 SERIAL » [ACK] (0x06) 09:41:56.899 DRIVER « [REQ] [SendData] callback id: 144 transmit status: OK 09:41:56.946 SERIAL « 0x010c00040020067006530203e81d (14 bytes) 09:41:56.951 CNTRLR [Node 032] [~] [Configuration] 83: 1000 => 1000 09:41:56.952 SERIAL » [ACK] (0x06) 09:41:56.953 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 83 value size: 2 value: 1000 09:41:56.956 SERIAL » 0x010a00131103700542259177 (12 bytes) 09:41:56.956 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 145 └─[ConfigurationCCGet] parameter #: 66 09:41:56.957 CNTRLR « [Node 032] parameter #83 has value: 1000 09:41:56.957 CNTRLR » [Node 032] querying parameter #86 value... 09:41:56.961 SERIAL « [ACK] (0x06) 09:41:56.967 SERIAL « 0x0104011301e8 (6 bytes) 09:41:56.967 SERIAL » [ACK] (0x06) 09:41:56.969 DRIVER « [RES] [SendData] was sent: true 09:41:57.029 SERIAL « 0x01070013910000077d (9 bytes) 09:41:57.029 SERIAL » [ACK] (0x06) 09:41:57.030 DRIVER « [REQ] [SendData] callback id: 145 transmit status: OK 09:41:57.040 SERIAL « 0x010c0004001106700642020000d6 (14 bytes) 09:41:57.045 CNTRLR [Node 017] [~] [Configuration] 66: 0 => 0 09:41:57.046 SERIAL » [ACK] (0x06) 09:41:57.047 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 66 value size: 2 value: 0 09:41:57.050 SERIAL » 0x010a00132003700556259251 (12 bytes) 09:41:57.050 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 146 └─[ConfigurationCCGet] parameter #: 86 09:41:57.051 CNTRLR « [Node 017] parameter #66 has value: 0 09:41:57.051 CNTRLR » [Node 017] querying parameter #80 value... 09:41:57.056 SERIAL « [ACK] (0x06) 09:41:57.060 SERIAL « 0x0104011301e8 (6 bytes) 09:41:57.060 SERIAL » [ACK] (0x06) 09:41:57.061 DRIVER « [RES] [SendData] was sent: true 09:41:57.097 SERIAL « 0x01070013920000047d (9 bytes) 09:41:57.097 SERIAL » [ACK] (0x06) 09:41:57.098 DRIVER « [REQ] [SendData] callback id: 146 transmit status: OK 09:41:57.146 SERIAL « 0x010b00040020057006560112e6 (13 bytes) 09:41:57.154 CNTRLR [Node 032] [~] [Configuration] 86: 18 => 18 09:41:57.155 SERIAL » [ACK] (0x06) 09:41:57.161 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 86 value size: 1 value: 18 09:41:57.165 SERIAL » 0x010a00131103700550259367 (12 bytes) 09:41:57.166 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 147 └─[ConfigurationCCGet] parameter #: 80 09:41:57.166 CNTRLR « [Node 032] parameter #86 has value: 18 09:41:57.167 CNTRLR » [Node 032] querying parameter #87 value... 09:41:57.170 SERIAL « [ACK] (0x06) 09:41:57.174 SERIAL « 0x0104011301e8 (6 bytes) 09:41:57.174 SERIAL » [ACK] (0x06) 09:41:57.175 DRIVER « [RES] [SendData] was sent: true 09:41:57.229 SERIAL « 0x01070013930000067e (9 bytes) 09:41:57.229 SERIAL » [ACK] (0x06) 09:41:57.230 DRIVER « [REQ] [SendData] callback id: 147 transmit status: OK 09:41:57.240 SERIAL « 0x010b00040011057006500100c3 (13 bytes) 09:41:57.245 CNTRLR [Node 017] [~] [Configuration] 80: 0 => 0 09:41:57.246 SERIAL » [ACK] (0x06) 09:41:57.246 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 80 value size: 1 value: 0 09:41:57.250 SERIAL » 0x010a00132003700557259456 (12 bytes) 09:41:57.250 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 148 └─[ConfigurationCCGet] parameter #: 87 09:41:57.251 CNTRLR « [Node 017] parameter #80 has value: 0 09:41:57.251 CNTRLR » [Node 017] querying parameter #81 value... 09:41:57.255 SERIAL « [ACK] (0x06) 09:41:57.260 SERIAL « 0x0104011301e8 (6 bytes) 09:41:57.260 SERIAL » [ACK] (0x06) 09:41:57.262 DRIVER « [RES] [SendData] was sent: true 09:41:57.297 SERIAL « 0x01070013940000047b (9 bytes) 09:41:57.297 SERIAL » [ACK] (0x06) 09:41:57.298 DRIVER « [REQ] [SendData] callback id: 148 transmit status: OK 09:41:57.344 SERIAL « 0x010b0004002005700657011ce9 (13 bytes) 09:41:57.349 CNTRLR [Node 032] [~] [Configuration] 87: 28 => 28 09:41:57.354 SERIAL » [ACK] (0x06) 09:41:57.355 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 87 value size: 1 value: 28 09:41:57.360 SERIAL » 0x010a00131103700551259560 (12 bytes) 09:41:57.361 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 149 └─[ConfigurationCCGet] parameter #: 81 09:41:57.362 CNTRLR « [Node 032] parameter #87 has value: 28 09:41:57.362 CNTRLR » [Node 032] querying parameter #89 value... 09:41:57.366 SERIAL « [ACK] (0x06) 09:41:57.370 SERIAL « 0x0104011301e8 (6 bytes) 09:41:57.370 SERIAL » [ACK] (0x06) 09:41:57.372 DRIVER « [RES] [SendData] was sent: true 09:41:57.429 SERIAL « 0x010700139500000678 (9 bytes) 09:41:57.429 SERIAL » [ACK] (0x06) 09:41:57.430 DRIVER « [REQ] [SendData] callback id: 149 transmit status: OK 09:41:57.440 SERIAL « 0x010b00040011057006510132f0 (13 bytes) 09:41:57.445 CNTRLR [Node 017] [~] [Configuration] 81: 50 => 50 09:41:57.446 SERIAL » [ACK] (0x06) 09:41:57.446 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 81 value size: 1 value: 50 09:41:57.449 SERIAL » 0x010a0013200370055925965a (12 bytes) 09:41:57.450 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 150 └─[ConfigurationCCGet] parameter #: 89 09:41:57.450 CNTRLR « [Node 017] parameter #81 has value: 50 09:41:57.451 CNTRLR » [Node 017] querying parameter #82 value... 09:41:57.455 SERIAL « [ACK] (0x06) 09:41:57.458 SERIAL « 0x0104011301e8 (6 bytes) 09:41:57.459 SERIAL » [ACK] (0x06) 09:41:57.460 DRIVER « [RES] [SendData] was sent: true 09:41:57.496 SERIAL « 0x010700139600000479 (9 bytes) 09:41:57.497 SERIAL » [ACK] (0x06) 09:41:57.497 DRIVER « [REQ] [SendData] callback id: 150 transmit status: OK 09:41:57.544 SERIAL « 0x010b00040020057006590101fa (13 bytes) 09:41:57.553 CNTRLR [Node 032] [~] [Configuration] 89: 1 => 1 09:41:57.555 SERIAL » [ACK] (0x06) 09:41:57.556 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 89 value size: 1 value: 1 09:41:57.562 SERIAL » 0x010a00131103700552259761 (12 bytes) 09:41:57.563 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 151 └─[ConfigurationCCGet] parameter #: 82 09:41:57.564 CNTRLR « [Node 032] parameter #89 has value: 1 09:41:57.565 CNTRLR [Node 032] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 09:41:57.644 SERIAL « [ACK] (0x06) 09:41:57.650 SERIAL « 0x0104011301e8 (6 bytes) 09:41:57.651 SERIAL » [ACK] (0x06) 09:41:57.652 DRIVER « [RES] [SendData] was sent: true 09:41:57.655 CNTRLR [Node 032] AlarmSensorCC: doing a partial interview... 09:41:57.656 CNTRLR » [Node 032] querying current value for General Purpose... 09:41:57.682 SERIAL « 0x01070013970000067a (9 bytes) 09:41:57.682 SERIAL » [ACK] (0x06) 09:41:57.684 DRIVER « [REQ] [SendData] callback id: 151 transmit status: OK 09:41:57.690 SERIAL « 0x010c0004001106700652020064a2 (14 bytes) 09:41:57.698 CNTRLR [Node 017] [~] [Configuration] 82: 100 => 100 09:41:57.700 SERIAL » [ACK] (0x06) 09:41:57.701 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 82 value size: 2 value: 100 09:41:57.705 SERIAL » 0x010a001320039c01002598e5 (12 bytes) 09:41:57.706 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 152 └─[AlarmSensorCCGet] sensor type: General Purpose 09:41:57.707 CNTRLR « [Node 017] parameter #82 has value: 100 09:41:57.707 CNTRLR » [Node 017] querying parameter #83 value... 09:41:57.712 SERIAL « [ACK] (0x06) 09:41:57.714 SERIAL « 0x0104011301e8 (6 bytes) 09:41:57.715 SERIAL » [ACK] (0x06) 09:41:57.717 DRIVER « [RES] [SendData] was sent: true 09:41:57.753 SERIAL « 0x010700139800000576 (9 bytes) 09:41:57.753 SERIAL » [ACK] (0x06) 09:41:57.754 DRIVER « [REQ] [SendData] callback id: 152 transmit status: OK 09:41:57.803 SERIAL « 0x010d00040020079c0220000000006f (15 bytes) 09:41:57.805 CNTRLR [Node 032] [~] [Alarm Sensor] state[0]: false => false [Endpoint 0] 09:41:57.805 CNTRLR [Node 032] [+] [Alarm Sensor] severity[0]: undefined [Endpoint 0] 09:41:57.806 CNTRLR [Node 032] [+] [Alarm Sensor] duration[0]: undefined [Endpoint 0] 09:41:57.807 SERIAL » [ACK] (0x06) 09:41:57.808 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: false 09:41:57.812 SERIAL » 0x010a0013110370055325996e (12 bytes) 09:41:57.812 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 153 └─[ConfigurationCCGet] parameter #: 83 09:41:57.814 CNTRLR « [Node 032] received current value for General Purpose: state: false 09:41:57.814 CNTRLR [Node 032] [~] [Alarm Sensor] interviewComplete: true [Endpoint 0] [internal] => true 09:41:57.865 SERIAL « [ACK] (0x06) 09:41:57.872 SERIAL « 0x0104011301e8 (6 bytes) 09:41:57.872 SERIAL » [ACK] (0x06) 09:41:57.875 DRIVER « [RES] [SendData] was sent: true 09:41:57.877 CNTRLR [Node 032] MultiChannelAssociationCC: doing a partial interview... 09:41:57.877 CNTRLR » [Node 032] querying multi channel association group #1... 09:41:57.889 SERIAL « 0x010700139900000775 (9 bytes) 09:41:57.889 SERIAL » [ACK] (0x06) 09:41:57.890 DRIVER « [REQ] [SendData] callback id: 153 transmit status: OK 09:41:57.900 SERIAL « 0x010c00040011067006530203e82c (14 bytes) 09:41:57.906 CNTRLR [Node 017] [~] [Configuration] 83: 1000 => 1000 09:41:57.907 SERIAL » [ACK] (0x06) 09:41:57.908 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 83 value size: 2 value: 1000 09:41:57.913 SERIAL » 0x010a001320038e0201259af7 (12 bytes) 09:41:57.914 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 154 └─[MultiChannelAssociationCCGet] group id: 1 09:41:57.915 CNTRLR « [Node 017] parameter #83 has value: 1000 09:41:57.917 CNTRLR » [Node 017] querying parameter #86 value... 09:41:57.923 SERIAL « [ACK] (0x06) 09:41:57.931 SERIAL « 0x0104011301e8 (6 bytes) 09:41:57.932 SERIAL » [ACK] (0x06) 09:41:57.933 DRIVER « [RES] [SendData] was sent: true 09:41:57.961 SERIAL « 0x010700139a00000475 (9 bytes) 09:41:57.962 SERIAL » [ACK] (0x06) 09:41:57.962 DRIVER « [REQ] [SendData] callback id: 154 transmit status: OK 09:41:58.010 SERIAL « 0x010c00040020068e030105000159 (14 bytes) 09:41:58.011 SERIAL » [ACK] (0x06) 09:41:58.013 CNTRLR [Node 032] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 09:41:58.014 CNTRLR [Node 032] [~] [Multi Channel Association] nodeIds[1]: 1 => 1 09:41:58.015 CNTRLR [Node 032] [~] [Multi Channel Association] endpoints[1]: => 09:41:58.017 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: 1 endpoints: 09:41:58.020 SERIAL » 0x010a00131103700556259b69 (12 bytes) 09:41:58.020 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 155 └─[ConfigurationCCGet] parameter #: 86 09:41:58.021 CNTRLR « [Node 032] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 09:41:58.021 CNTRLR » [Node 032] querying multi channel association group #2... 09:41:58.025 SERIAL « [ACK] (0x06) 09:41:58.032 SERIAL « 0x0104011301e8 (6 bytes) 09:41:58.032 SERIAL » [ACK] (0x06) 09:41:58.033 DRIVER « [RES] [SendData] was sent: true 09:41:58.099 SERIAL « 0x010700139b00000777 (9 bytes) 09:41:58.099 SERIAL » [ACK] (0x06) 09:41:58.100 DRIVER « [REQ] [SendData] callback id: 155 transmit status: OK 09:41:58.110 SERIAL « 0x010b00040011057006560112d7 (13 bytes) 09:41:58.115 CNTRLR [Node 017] [~] [Configuration] 86: 18 => 18 09:41:58.116 SERIAL » [ACK] (0x06) 09:41:58.116 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 86 value size: 1 value: 18 09:41:58.120 SERIAL » 0x010a001320038e0202259cf2 (12 bytes) 09:41:58.120 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 156 └─[MultiChannelAssociationCCGet] group id: 2 09:41:58.121 CNTRLR « [Node 017] parameter #86 has value: 18 09:41:58.121 CNTRLR » [Node 017] querying parameter #87 value... 09:41:58.124 SERIAL « [ACK] (0x06) 09:41:58.129 SERIAL « 0x0104011301e8 (6 bytes) 09:41:58.129 SERIAL » [ACK] (0x06) 09:41:58.130 DRIVER « [RES] [SendData] was sent: true 09:41:58.167 SERIAL « 0x010700139c00000473 (9 bytes) 09:41:58.167 SERIAL » [ACK] (0x06) 09:41:58.168 DRIVER « [REQ] [SendData] callback id: 156 transmit status: OK 09:41:58.216 SERIAL « 0x010c00040020068e03020500015a (14 bytes) 09:41:58.217 SERIAL » [ACK] (0x06) 09:41:58.218 CNTRLR [Node 032] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 09:41:58.219 CNTRLR [Node 032] [~] [Multi Channel Association] nodeIds[2]: 1 => 1 09:41:58.220 CNTRLR [Node 032] [~] [Multi Channel Association] endpoints[2]: => 09:41:58.222 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: 1 endpoints: 09:41:58.225 SERIAL » 0x010a00131103700557259d6e (12 bytes) 09:41:58.226 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 157 └─[ConfigurationCCGet] parameter #: 87 09:41:58.227 CNTRLR « [Node 032] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 09:41:58.227 CNTRLR » [Node 032] querying additional non-multi-channel association groups... 09:41:58.227 CNTRLR » [Node 032] querying association group #3... 09:41:58.232 SERIAL « [ACK] (0x06) 09:41:58.236 SERIAL « 0x0104011301e8 (6 bytes) 09:41:58.237 SERIAL » [ACK] (0x06) 09:41:58.238 DRIVER « [RES] [SendData] was sent: true 09:41:58.310 SERIAL « 0x010700139d0000087e (9 bytes) 09:41:58.311 SERIAL » [ACK] (0x06) 09:41:58.311 DRIVER « [REQ] [SendData] callback id: 157 transmit status: OK 09:41:58.320 SERIAL « 0x010b0004001105700657011cd8 (13 bytes) 09:41:58.325 CNTRLR [Node 017] [~] [Configuration] 87: 28 => 28 09:41:58.326 SERIAL » [ACK] (0x06) 09:41:58.327 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 87 value size: 1 value: 28 09:41:58.331 SERIAL » 0x010a00132003850203259efa (12 bytes) 09:41:58.332 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 158 └─[AssociationCCGet] group id: 3 09:41:58.333 CNTRLR « [Node 017] parameter #87 has value: 28 09:41:58.333 CNTRLR » [Node 017] querying parameter #89 value... 09:41:58.336 SERIAL « [ACK] (0x06) 09:41:58.342 SERIAL « 0x0104011301e8 (6 bytes) 09:41:58.343 SERIAL » [ACK] (0x06) 09:41:58.345 DRIVER « [RES] [SendData] was sent: true 09:41:58.379 SERIAL « 0x010700139e00000471 (9 bytes) 09:41:58.379 SERIAL » [ACK] (0x06) 09:41:58.380 DRIVER « [REQ] [SendData] callback id: 158 transmit status: OK 09:41:58.415 SERIAL « 0x010c000400030631050422047b9f (14 bytes) 09:41:58.416 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:41:58.417 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 237 => 114.7 [Endpoint 0] 09:41:58.418 SERIAL » [ACK] (0x06) 09:41:58.419 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 114.7 09:41:58.429 SERIAL « 0x010c000400200685030301000154 (14 bytes) 09:41:58.430 SERIAL » [ACK] (0x06) 09:41:58.432 CNTRLR [Node 032] [~] [Association] maxNodes[3]: 1 => 1 [internal] 09:41:58.432 CNTRLR [Node 032] [~] [Association] nodeIds[3]: 1 => 1 [internal] 09:41:58.433 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 09:41:58.437 SERIAL » 0x010a00131103700559259f62 (12 bytes) 09:41:58.438 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 159 └─[ConfigurationCCGet] parameter #: 89 09:41:58.439 CNTRLR « [Node 032] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 09:41:58.440 CNTRLR [Node 032] [~] [Association] hasLifeline: true => true [internal] 09:41:58.440 CNTRLR [Node 032] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 09:41:58.479 SERIAL « [ACK] (0x06) 09:41:58.483 SERIAL « 0x0104011301e8 (6 bytes) 09:41:58.484 SERIAL » [ACK] (0x06) 09:41:58.485 DRIVER « [RES] [SendData] was sent: true 09:41:58.493 CNTRLR [Node 032] Interview stage completed: CommandClasses 09:41:58.493 CNTRLR [Node 032] Interview stage completed: OverwriteConfig 09:41:58.494 CNTRLR » [Node 032] requesting node neighbors... 09:41:58.534 SERIAL « 0x010700139f00000a7e (9 bytes) 09:41:58.535 SERIAL » [ACK] (0x06) 09:41:58.535 DRIVER « [REQ] [SendData] callback id: 159 transmit status: OK 09:42:00.139 CNTRLR [Node 017] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:42:00.645 SERIAL » 0x010a00131103700559259f62 (12 bytes) 09:42:00.646 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 159 └─[ConfigurationCCGet] parameter #: 89 09:42:00.648 SERIAL « [ACK] (0x06) 09:42:00.654 SERIAL « 0x0104011301e8 (6 bytes) 09:42:00.655 SERIAL » [ACK] (0x06) 09:42:00.656 DRIVER « [RES] [SendData] was sent: true 09:42:00.672 SERIAL « 0x010700139f00000276 (9 bytes) 09:42:00.672 SERIAL » [ACK] (0x06) 09:42:00.673 DRIVER « [REQ] [SendData] callback id: 159 transmit status: OK 09:42:00.682 SERIAL « 0x010b00040011057006590101cb (13 bytes) 09:42:00.694 CNTRLR [Node 017] [~] [Configuration] 89: 1 => 1 09:42:00.696 SERIAL » [ACK] (0x06) 09:42:00.697 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 89 value size: 1 value: 1 09:42:00.715 SERIAL » 0x010700802000000058 (9 bytes) 09:42:00.716 DRIVER » [Node 032] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:42:00.718 CNTRLR « [Node 017] parameter #89 has value: 1 09:42:00.718 CNTRLR [Node 017] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 09:42:00.764 SERIAL « [ACK] (0x06) 09:42:00.765 SERIAL « 0x01200180000000000000000000000000000000000000000000000000000000000 (34 bytes) 05e 09:42:00.766 SERIAL » [ACK] (0x06) 09:42:00.770 DRIVER « [RES] [GetRoutingInfo] node ids: 09:42:00.773 CNTRLR « [Node 032] node neighbors received: 09:42:00.773 CNTRLR [Node 032] Interview stage completed: Neighbors 09:42:00.773 CNTRLR [Node 032] Interview completed 09:42:00.778 CNTRLR [Node 017] AlarmSensorCC: doing a partial interview... 09:42:00.779 CNTRLR » [Node 017] querying current value for General Purpose... 09:42:00.783 SERIAL » 0x010a001311039c010025a0ec (12 bytes) 09:42:00.783 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 160 └─[AlarmSensorCCGet] sensor type: General Purpose 09:42:00.785 SERIAL « [ACK] (0x06) 09:42:00.791 SERIAL « 0x0104011301e8 (6 bytes) 09:42:00.791 SERIAL » [ACK] (0x06) 09:42:00.792 DRIVER « [RES] [SendData] was sent: true 09:42:00.808 SERIAL « 0x01070013a000000249 (9 bytes) 09:42:00.809 SERIAL » [ACK] (0x06) 09:42:00.809 DRIVER « [REQ] [SendData] callback id: 160 transmit status: OK 09:42:00.820 SERIAL « 0x010d00040011079c0211000000006f (15 bytes) 09:42:00.820 CNTRLR [Node 017] [~] [Alarm Sensor] state[0]: false => false [Endpoint 0] 09:42:00.821 CNTRLR [Node 017] [+] [Alarm Sensor] severity[0]: undefined [Endpoint 0] 09:42:00.821 CNTRLR [Node 017] [+] [Alarm Sensor] duration[0]: undefined [Endpoint 0] 09:42:00.822 SERIAL » [ACK] (0x06) 09:42:00.823 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: false 09:42:00.825 CNTRLR « [Node 017] received current value for General Purpose: state: false 09:42:00.825 CNTRLR [Node 017] [~] [Alarm Sensor] interviewComplete: true [Endpoint 0] [internal] => true 09:42:00.825 CNTRLR [Node 017] MultiChannelAssociationCC: doing a partial interview... 09:42:00.826 CNTRLR » [Node 017] querying multi channel association group #1... 09:42:00.829 SERIAL » 0x010a001311038e020125a1fd (12 bytes) 09:42:00.830 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 161 └─[MultiChannelAssociationCCGet] group id: 1 09:42:00.834 SERIAL « [ACK] (0x06) 09:42:00.848 SERIAL « 0x0104011301e8 (6 bytes) 09:42:00.848 SERIAL » [ACK] (0x06) 09:42:00.849 DRIVER « [RES] [SendData] was sent: true 09:42:00.855 SERIAL « 0x01070013a100000248 (9 bytes) 09:42:00.856 SERIAL » [ACK] (0x06) 09:42:00.856 DRIVER « [REQ] [SendData] callback id: 161 transmit status: OK 09:42:00.866 SERIAL « 0x010c00040011068e030105000168 (14 bytes) 09:42:00.867 SERIAL » [ACK] (0x06) 09:42:00.868 CNTRLR [Node 017] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 09:42:00.869 CNTRLR [Node 017] [~] [Multi Channel Association] nodeIds[1]: 1 => 1 09:42:00.870 CNTRLR [Node 017] [~] [Multi Channel Association] endpoints[1]: => 09:42:00.871 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: 1 endpoints: 09:42:00.872 CNTRLR « [Node 017] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 09:42:00.872 CNTRLR » [Node 017] querying multi channel association group #2... 09:42:00.876 SERIAL » 0x010a001311038e020225a2fd (12 bytes) 09:42:00.876 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 162 └─[MultiChannelAssociationCCGet] group id: 2 09:42:00.879 SERIAL « [ACK] (0x06) 09:42:00.888 SERIAL « 0x0104011301e8 (6 bytes) 09:42:00.888 SERIAL » [ACK] (0x06) 09:42:00.890 DRIVER « [RES] [SendData] was sent: true 09:42:00.902 SERIAL « 0x01070013a20000024b (9 bytes) 09:42:00.902 SERIAL » [ACK] (0x06) 09:42:00.903 DRIVER « [REQ] [SendData] callback id: 162 transmit status: OK 09:42:00.912 SERIAL « 0x010c00040011068e03020500016b (14 bytes) 09:42:00.913 SERIAL » [ACK] (0x06) 09:42:00.914 CNTRLR [Node 017] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 09:42:00.915 CNTRLR [Node 017] [~] [Multi Channel Association] nodeIds[2]: 1 => 1 09:42:00.916 CNTRLR [Node 017] [~] [Multi Channel Association] endpoints[2]: => 09:42:00.917 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: 1 endpoints: 09:42:00.918 CNTRLR « [Node 017] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 09:42:00.918 CNTRLR » [Node 017] querying additional non-multi-channel association groups... 09:42:00.919 CNTRLR » [Node 017] querying association group #3... 09:42:00.922 SERIAL » 0x010a0013110385020325a3f6 (12 bytes) 09:42:00.923 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 163 └─[AssociationCCGet] group id: 3 09:42:00.925 SERIAL « [ACK] (0x06) 09:42:00.937 SERIAL « 0x0104011301e8 (6 bytes) 09:42:00.937 SERIAL » [ACK] (0x06) 09:42:00.938 DRIVER « [RES] [SendData] was sent: true 09:42:01.017 SERIAL « 0x01070013a300000941 (9 bytes) 09:42:01.017 SERIAL » [ACK] (0x06) 09:42:01.018 DRIVER « [REQ] [SendData] callback id: 163 transmit status: OK 09:42:01.029 SERIAL « 0x010c000400110685030301000165 (14 bytes) 09:42:01.029 SERIAL » [ACK] (0x06) 09:42:01.030 CNTRLR [Node 017] [~] [Association] maxNodes[3]: 1 => 1 [internal] 09:42:01.030 CNTRLR [Node 017] [~] [Association] nodeIds[3]: 1 => 1 [internal] 09:42:01.030 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 09:42:01.032 CNTRLR « [Node 017] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 09:42:01.032 CNTRLR [Node 017] [~] [Association] hasLifeline: true => true [internal] 09:42:01.033 CNTRLR [Node 017] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 09:42:01.058 SERIAL « 0x0110000400230a600d02003105012200bd07 (18 bytes) 09:42:01.059 CNTRLR [Node 035] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:42:01.060 CNTRLR [Node 035] [~] [Multilevel Sensor] Air temperature: 18.9 => 18.9 [Endpoint 2] 09:42:01.060 SERIAL » [ACK] (0x06) 09:42:01.063 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.9 09:42:01.066 CNTRLR [Node 017] Interview stage completed: CommandClasses 09:42:01.066 CNTRLR [Node 017] Interview stage completed: OverwriteConfig 09:42:01.067 CNTRLR » [Node 017] requesting node neighbors... 09:42:01.075 SERIAL » 0x010700801100000069 (9 bytes) 09:42:01.076 DRIVER » [Node 017] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:42:01.078 SERIAL « [ACK] (0x06) 09:42:01.085 SERIAL « 0x0120018005c000000000000000000000000000000000000000000000000000000 (34 bytes) 09b 09:42:01.086 SERIAL » [ACK] (0x06) 09:42:01.087 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 15, 16 09:42:01.105 CNTRLR « [Node 017] node neighbors received: 1, 3, 15, 16 09:42:01.106 CNTRLR [Node 017] Interview stage completed: Neighbors 09:42:01.106 CNTRLR [Node 017] Interview completed 09:42:01.775 CNTRLR » [Node 032] Sending node back to sleep... 09:42:01.780 SERIAL » 0x010900132002840825a4ca (11 bytes) 09:42:01.780 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 164 └─[WakeUpCCNoMoreInformation] 09:42:01.782 SERIAL « [ACK] (0x06) 09:42:01.788 SERIAL « 0x0104011301e8 (6 bytes) 09:42:01.789 SERIAL » [ACK] (0x06) 09:42:01.789 DRIVER « [RES] [SendData] was sent: true 09:42:01.827 SERIAL « 0x01070013a40000044b (9 bytes) 09:42:01.827 SERIAL » [ACK] (0x06) 09:42:01.828 DRIVER « [REQ] [SendData] callback id: 164 transmit status: OK 09:42:01.831 CNTRLR [Node 032] The node is now asleep. 09:42:01.833 CNTRLR [Node 032] Node asleep 09:42:02.107 CNTRLR » [Node 017] Sending node back to sleep... 09:42:02.111 SERIAL » 0x010900131102840825a5fa (11 bytes) 09:42:02.111 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 165 └─[WakeUpCCNoMoreInformation] 09:42:02.113 SERIAL « [ACK] (0x06) 09:42:02.119 SERIAL « 0x0104011301e8 (6 bytes) 09:42:02.120 SERIAL » [ACK] (0x06) 09:42:02.120 DRIVER « [RES] [SendData] was sent: true 09:42:02.136 SERIAL « 0x01070013a50000024c (9 bytes) 09:42:02.137 SERIAL » [ACK] (0x06) 09:42:02.137 DRIVER « [REQ] [SendData] callback id: 165 transmit status: OK 09:42:02.140 CNTRLR [Node 017] The node is now asleep. 09:42:02.141 CNTRLR [Node 017] Node asleep 09:42:02.918 SERIAL « 0x01090004001b03300300d9 (11 bytes) 09:42:02.919 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:42:02.919 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:42:02.920 SERIAL » [ACK] (0x06) 09:42:02.921 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:42:02.972 SERIAL « 0x01090004001b03200100cb (11 bytes) 09:42:02.973 SERIAL » [ACK] (0x06) 09:42:02.974 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:42:02.976 CNTRLR [Node 027] treating BasicCC Set as a report 09:42:02.976 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:42:04.333 SERIAL « 0x010c0004000306310504220bb65d (14 bytes) 09:42:04.334 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:42:04.336 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 114.7 => 299.8 [Endpoint 0] 09:42:04.336 SERIAL » [ACK] (0x06) 09:42:04.338 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 299.8 09:42:05.333 SERIAL « 0x010c000400030631050422087c94 (14 bytes) 09:42:05.334 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:42:05.336 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 299.8 => 217.2 [Endpoint 0] 09:42:05.337 SERIAL » [ACK] (0x06) 09:42:05.338 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 217.2 09:42:24.335 SERIAL « 0x010c0004000306310504220516f3 (14 bytes) 09:42:24.336 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:42:24.337 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 217.2 => 130.2 [Endpoint 0] 09:42:24.338 SERIAL » [ACK] (0x06) 09:42:24.340 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 130.2 09:42:28.337 SERIAL « 0x010c00040003063105042207ed0a (14 bytes) 09:42:28.338 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:42:28.339 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 130.2 => 202.9 [Endpoint 0] 09:42:28.341 SERIAL » [ACK] (0x06) 09:42:28.343 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 202.9 09:42:30.336 SERIAL « 0x010c00040003063105042204bf5b (14 bytes) 09:42:30.337 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:42:30.337 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 202.9 => 121.5 [Endpoint 0] 09:42:30.338 SERIAL » [ACK] (0x06) 09:42:30.338 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 121.5 09:42:37.337 SERIAL « 0x010c0004000306310504220406e2 (14 bytes) 09:42:37.338 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:42:37.339 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 121.5 => 103 [Endpoint 0] 09:42:37.340 SERIAL » [ACK] (0x06) 09:42:37.342 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 103 09:42:38.337 SERIAL « 0x010c00040003063105042209ec05 (14 bytes) 09:42:38.338 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:42:38.339 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 103 => 254 [Endpoint 0] 09:42:38.340 SERIAL » [ACK] (0x06) 09:42:38.342 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 254 09:42:53.338 SERIAL « 0x010c0004000306310504220419fd (14 bytes) 09:42:53.339 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:42:53.340 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 254 => 104.9 [Endpoint 0] 09:42:53.341 SERIAL » [ACK] (0x06) 09:42:53.343 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 104.9 09:42:54.338 SERIAL « 0x010c0004000306310504220a13f9 (14 bytes) 09:42:54.339 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:42:54.339 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 104.9 => 257.9 [Endpoint 0] 09:42:54.340 SERIAL » [ACK] (0x06) 09:42:54.342 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 257.9 09:42:55.339 SERIAL « 0x010c000400030631050422084ea6 (14 bytes) 09:42:55.341 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:42:55.341 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 257.9 => 212.6 [Endpoint 0] 09:42:55.342 SERIAL » [ACK] (0x06) 09:42:55.344 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 212.6 09:42:56.339 SERIAL « 0x010c000400030631050422048367 (14 bytes) 09:42:56.340 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:42:56.341 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 212.6 => 115.5 [Endpoint 0] 09:42:56.342 SERIAL » [ACK] (0x06) 09:42:56.344 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 115.5 09:42:59.339 SERIAL « 0x010c0004000306310504220846ae (14 bytes) 09:42:59.340 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:42:59.342 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 115.5 => 211.8 [Endpoint 0] 09:42:59.343 SERIAL » [ACK] (0x06) 09:42:59.345 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 211.8 09:43:24.342 SERIAL « 0x010c000400030631050422047c98 (14 bytes) 09:43:24.343 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:43:24.344 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 211.8 => 114.8 [Endpoint 0] 09:43:24.345 SERIAL » [ACK] (0x06) 09:43:24.347 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 114.8 09:43:25.342 SERIAL « 0x010c000400030631050422060fe9 (14 bytes) 09:43:25.342 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:43:25.343 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 114.8 => 155.1 [Endpoint 0] 09:43:25.343 SERIAL » [ACK] (0x06) 09:43:25.344 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 155.1 09:43:27.342 SERIAL « 0x010c000400030631050422049c78 (14 bytes) 09:43:27.344 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:43:27.345 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 155.1 => 118 [Endpoint 0] 09:43:27.346 SERIAL » [ACK] (0x06) 09:43:27.348 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 118 09:43:32.343 SERIAL « 0x010c00040003063105042208cc24 (14 bytes) 09:43:32.344 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:43:32.345 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 118 => 225.2 [Endpoint 0] 09:43:32.346 SERIAL » [ACK] (0x06) 09:43:32.348 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 225.2 09:43:33.343 SERIAL « 0x010c00040003063105042204de3a (14 bytes) 09:43:33.343 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:43:33.344 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 225.2 => 124.6 [Endpoint 0] 09:43:33.344 SERIAL » [ACK] (0x06) 09:43:33.346 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 124.6 09:43:38.634 SERIAL « 0x010900040008033003ff35 (11 bytes) 09:43:38.635 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:43:38.636 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:43:38.636 SERIAL » [ACK] (0x06) 09:43:38.637 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:43:38.689 SERIAL « 0x010900040008032001ff27 (11 bytes) 09:43:38.689 SERIAL » [ACK] (0x06) 09:43:38.690 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:43:38.691 CNTRLR [Node 008] treating BasicCC Set as a report 09:43:38.691 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:43:40.611 SERIAL « 0x0108000400060298402f (10 bytes) 09:43:40.613 SERIAL » [ACK] (0x06) 09:43:40.614 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:43:40.629 SERIAL » 0x01110013060a988037ec2bfc92b0e932240038 (19 bytes) 09:43:40.630 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x37ec2bfc92b0e932 09:43:40.632 SERIAL « [ACK] (0x06) 09:43:40.639 SERIAL « 0x0104011301e8 (6 bytes) 09:43:40.639 SERIAL » [ACK] (0x06) 09:43:40.640 DRIVER « [RES] [SendData] was sent: true 09:43:40.682 SERIAL « 0x0124000400061e9881f9dd5a6fd0aa07fa991c07ee8a6bc06611cb133759b4623 (38 bytes) c5a7f5d4610 09:43:40.688 SERIAL » [ACK] (0x06) 09:43:40.690 CNTRLR [Node 006] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:43:40.691 CNTRLR [Node 006] [~] [Multilevel Sensor] Air temperature: 21.7 => 21.1 [Endpoint 2] 09:43:40.698 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 21.1 09:43:43.344 SERIAL « 0x010c0004000306310504220959b0 (14 bytes) 09:43:43.345 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:43:43.347 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 124.6 => 239.3 [Endpoint 0] 09:43:43.348 SERIAL » [ACK] (0x06) 09:43:43.351 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 239.3 09:43:55.345 SERIAL « 0x010c0004000306310504220558bd (14 bytes) 09:43:55.346 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:43:55.347 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 239.3 => 136.8 [Endpoint 0] 09:43:55.348 SERIAL » [ACK] (0x06) 09:43:55.350 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 136.8 09:43:56.345 SERIAL « 0x010c000400030631050422088b63 (14 bytes) 09:43:56.346 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:43:56.346 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 136.8 => 218.7 [Endpoint 0] 09:43:56.347 SERIAL » [ACK] (0x06) 09:43:56.348 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 218.7 09:43:57.345 SERIAL « 0x010c00040003063105042203e300 (14 bytes) 09:43:57.347 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:43:57.348 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 218.7 => 99.5 [Endpoint 0] 09:43:57.349 SERIAL » [ACK] (0x06) 09:43:57.351 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 99.5 09:43:58.345 SERIAL « 0x010c00040003063105042204b256 (14 bytes) 09:43:58.346 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:43:58.346 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 99.5 => 120.2 [Endpoint 0] 09:43:58.347 SERIAL » [ACK] (0x06) 09:43:58.348 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 120.2 09:44:02.743 SERIAL « 0x0112000400180c600d02003202213202cb000078 (20 bytes) 09:44:02.748 CNTRLR [Node 024] [~] [Meter] value[66049]: 96.6 => 71.5 [Endpoint 2] 09:44:02.750 CNTRLR [Node 024] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 2] 09:44:02.751 SERIAL » [ACK] (0x06) 09:44:02.759 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 71.5 time delta: 0 seconds 09:44:07.347 SERIAL « 0x010c0004000306310504220751b6 (14 bytes) 09:44:07.348 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:44:07.349 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 120.2 => 187.3 [Endpoint 0] 09:44:07.350 SERIAL » [ACK] (0x06) 09:44:07.353 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 187.3 09:44:09.385 SERIAL « 0x01090004000803300300ca (11 bytes) 09:44:09.387 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:44:09.388 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:44:09.389 SERIAL » [ACK] (0x06) 09:44:09.391 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:44:09.439 SERIAL « 0x01090004000803200100d8 (11 bytes) 09:44:09.440 SERIAL » [ACK] (0x06) 09:44:09.441 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:44:09.443 CNTRLR [Node 008] treating BasicCC Set as a report 09:44:09.443 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:44:12.743 SERIAL « 0x0112000400180c600d02003202213204450000f0 (20 bytes) 09:44:12.744 CNTRLR [Node 024] [~] [Meter] value[66049]: 71.5 => 109.3 [Endpoint 2] 09:44:12.746 CNTRLR [Node 024] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 2] 09:44:12.747 SERIAL » [ACK] (0x06) 09:44:12.750 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 109.3 time delta: 0 seconds 09:44:13.231 SERIAL « 0x01090004001b033003ff26 (11 bytes) 09:44:13.233 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:44:13.234 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:44:13.235 SERIAL » [ACK] (0x06) 09:44:13.237 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:44:13.285 SERIAL « 0x01090004001b032001ff34 (11 bytes) 09:44:13.286 SERIAL » [ACK] (0x06) 09:44:13.287 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:44:13.290 CNTRLR [Node 027] treating BasicCC Set as a report 09:44:13.290 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:44:13.529 SERIAL « 0x010900040008033003ff35 (11 bytes) 09:44:13.530 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:44:13.531 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:44:13.532 SERIAL » [ACK] (0x06) 09:44:13.535 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:44:13.583 SERIAL « 0x010900040008032001ff27 (11 bytes) 09:44:13.584 SERIAL » [ACK] (0x06) 09:44:13.585 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:44:13.591 CNTRLR [Node 008] treating BasicCC Set as a report 09:44:13.592 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:44:20.766 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 09:44:20.770 SERIAL » [ACK] (0x06) 09:44:20.773 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 09:44:20.778 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 09:44:25.170 SERIAL « 0x01090004001e033003ff23 (11 bytes) 09:44:25.171 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:44:25.173 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:44:25.174 SERIAL » [ACK] (0x06) 09:44:25.176 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:44:25.205 SERIAL » 0x010e00131f07600d00012501ff25a6ce (16 bytes) 09:44:25.206 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 166 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCSet] target value: true 09:44:25.208 SERIAL « [ACK] (0x06) 09:44:25.214 SERIAL « 0x0104011301e8 (6 bytes) 09:44:25.215 SERIAL » [ACK] (0x06) 09:44:25.216 DRIVER « [RES] [SendData] was sent: true 09:44:25.224 SERIAL « 0x01090004001e032001ff31 (11 bytes) 09:44:25.225 SERIAL » [ACK] (0x06) 09:44:25.226 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:44:25.234 CNTRLR [Node 030] treating BasicCC Set as a report 09:44:25.235 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:44:25.269 SERIAL « 0x01070013a60000064b (9 bytes) 09:44:25.269 SERIAL » [ACK] (0x06) 09:44:25.271 DRIVER « [REQ] [SendData] callback id: 166 transmit status: OK 09:44:25.280 SERIAL » 0x010d00131f06600d0001250225a731 (15 bytes) 09:44:25.280 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 167 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 09:44:25.282 SERIAL « [ACK] (0x06) 09:44:25.289 SERIAL « 0x0104011301e8 (6 bytes) 09:44:25.289 SERIAL » [ACK] (0x06) 09:44:25.290 DRIVER « [RES] [SendData] was sent: true 09:44:25.307 SERIAL « 0x01070013a70000024e (9 bytes) 09:44:25.307 SERIAL » [ACK] (0x06) 09:44:25.307 DRIVER « [REQ] [SendData] callback id: 167 transmit status: OK 09:44:25.318 SERIAL « 0x010d0004001f07600d01002503ff5b (15 bytes) 09:44:25.319 CNTRLR [Node 031] [~] [Binary Switch] currentValue: false => true [Endpoint 1] 09:44:25.319 SERIAL » [ACK] (0x06) 09:44:25.321 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: true 09:44:26.349 SERIAL « 0x010c000400030631050422049571 (14 bytes) 09:44:26.350 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:44:26.352 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 187.3 => 117.3 [Endpoint 0] 09:44:26.353 SERIAL » [ACK] (0x06) 09:44:26.355 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 117.3 09:44:44.244 SERIAL « 0x01090004000803300300ca (11 bytes) 09:44:44.245 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:44:44.246 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:44:44.247 SERIAL » [ACK] (0x06) 09:44:44.249 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:44:44.298 SERIAL « 0x01090004000803200100d8 (11 bytes) 09:44:44.299 SERIAL » [ACK] (0x06) 09:44:44.300 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:44:44.302 CNTRLR [Node 008] treating BasicCC Set as a report 09:44:44.303 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:44:49.743 SERIAL « 0x0112000400180c600d01003202213200000000b2 (20 bytes) 09:44:49.745 CNTRLR [Node 024] [~] [Meter] value[66049]: 0 => 0 [Endpoint 1] 09:44:49.746 CNTRLR [Node 024] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 1] 09:44:49.747 SERIAL » [ACK] (0x06) 09:44:49.750 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 09:44:51.535 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 09:44:51.536 SERIAL » [ACK] (0x06) 09:44:51.538 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  09:44:51.541 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 09:44:54.611 SERIAL « 0x01090004001b03300300d9 (11 bytes) 09:44:54.612 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:44:54.613 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:44:54.614 SERIAL » [ACK] (0x06) 09:44:54.615 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:44:54.666 SERIAL « 0x01090004001b03200100cb (11 bytes) 09:44:54.666 SERIAL » [ACK] (0x06) 09:44:54.667 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:44:54.670 CNTRLR [Node 027] treating BasicCC Set as a report 09:44:54.670 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:44:56.027 SERIAL « 0x01090004001e03300300dc (11 bytes) 09:44:56.028 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:44:56.029 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:44:56.030 SERIAL » [ACK] (0x06) 09:44:56.031 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:44:56.080 SERIAL « 0x01090004001e03200100ce (11 bytes) 09:44:56.081 SERIAL » [ACK] (0x06) 09:44:56.082 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:44:56.084 CNTRLR [Node 030] treating BasicCC Set as a report 09:44:56.084 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:45:56.055 SERIAL » 0x010e00131f07600d000125010025a83f (16 bytes) 09:45:56.056 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 168 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCSet] target value: false 09:45:56.058 SERIAL « [ACK] (0x06) 09:45:56.064 SERIAL « 0x0104011301e8 (6 bytes) 09:45:56.065 SERIAL » [ACK] (0x06) 09:45:56.066 DRIVER « [RES] [SendData] was sent: true 09:45:56.083 SERIAL « 0x01070013a800000241 (9 bytes) 09:45:56.083 SERIAL » [ACK] (0x06) 09:45:56.084 DRIVER « [REQ] [SendData] callback id: 168 transmit status: OK 09:45:56.094 SERIAL » 0x010d00131f06600d0001250225a93f (15 bytes) 09:45:56.095 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 169 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 09:45:56.097 SERIAL « [ACK] (0x06) 09:45:56.103 SERIAL « 0x0104011301e8 (6 bytes) 09:45:56.104 SERIAL » [ACK] (0x06) 09:45:56.105 DRIVER « [RES] [SendData] was sent: true 09:45:56.121 SERIAL « 0x01070013a900000240 (9 bytes) 09:45:56.122 SERIAL » [ACK] (0x06) 09:45:56.123 DRIVER « [REQ] [SendData] callback id: 169 transmit status: OK 09:45:56.133 SERIAL « 0x010d0004001f07600d0100250300a4 (15 bytes) 09:45:56.134 CNTRLR [Node 031] [~] [Binary Switch] currentValue: true => false [Endpoint 1] 09:45:56.135 SERIAL » [ACK] (0x06) 09:45:56.136 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: false 09:46:56.386 SERIAL « 0x010c00040002063105030a000cc2 (14 bytes) 09:46:56.387 CNTRLR [Node 002] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 09:46:56.388 CNTRLR [Node 002] [~] [Multilevel Sensor] Illuminance: 11 => 12 [Endpoint 0] 09:46:56.389 SERIAL » [ACK] (0x06) 09:46:56.390 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 12 09:48:12.372 SERIAL « 0x010c00040003063105042208a34b (14 bytes) 09:48:12.373 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:48:12.375 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 117.3 => 221.1 [Endpoint 0] 09:48:12.376 SERIAL » [ACK] (0x06) 09:48:12.377 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 221.1 09:48:13.372 SERIAL « 0x010c00040003063105042203c320 (14 bytes) 09:48:13.373 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:48:13.373 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 221.1 => 96.3 [Endpoint 0] 09:48:13.374 SERIAL » [ACK] (0x06) 09:48:13.375 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 96.3 09:48:14.373 SERIAL « 0x010c000400030631050422049d79 (14 bytes) 09:48:14.374 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:48:14.375 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 96.3 => 118.1 [Endpoint 0] 09:48:14.376 SERIAL » [ACK] (0x06) 09:48:14.378 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 118.1 09:48:22.373 SERIAL « 0x010c00040003063105042208b75f (14 bytes) 09:48:22.374 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:48:22.375 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 118.1 => 223.1 [Endpoint 0] 09:48:22.376 SERIAL » [ACK] (0x06) 09:48:22.378 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 223.1 09:48:24.374 SERIAL « 0x010c000400030631050422044fab (14 bytes) 09:48:24.375 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:48:24.376 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 223.1 => 110.3 [Endpoint 0] 09:48:24.377 SERIAL » [ACK] (0x06) 09:48:24.379 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 110.3 09:48:25.373 SERIAL « 0x010c0004000306310504220859b1 (14 bytes) 09:48:25.374 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:48:25.376 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 110.3 => 213.7 [Endpoint 0] 09:48:25.377 SERIAL » [ACK] (0x06) 09:48:25.379 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 213.7 09:48:34.375 SERIAL « 0x010c000400030631050422047591 (14 bytes) 09:48:34.376 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:48:34.377 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 213.7 => 114.1 [Endpoint 0] 09:48:34.378 SERIAL » [ACK] (0x06) 09:48:34.381 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 114.1 09:48:53.610 SERIAL « 0x01100004001c0a600d02003105012200c742 (18 bytes) 09:48:53.611 CNTRLR [Node 028] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:48:53.614 CNTRLR [Node 028] [~] [Multilevel Sensor] Air temperature: 20.1 => 19.9 [Endpoint 2] 09:48:53.616 SERIAL » [ACK] (0x06) 09:48:53.618 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 19.9 09:49:19.379 SERIAL « 0x010c000400030631050422090de4 (14 bytes) 09:49:19.380 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:49:19.381 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 114.1 => 231.7 [Endpoint 0] 09:49:19.382 SERIAL » [ACK] (0x06) 09:49:19.384 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 231.7 09:49:20.379 SERIAL « 0x010c000400030631050422044baf (14 bytes) 09:49:20.380 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:49:20.381 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 231.7 => 109.9 [Endpoint 0] 09:49:20.383 SERIAL » [ACK] (0x06) 09:49:20.384 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 109.9 09:49:39.833 SERIAL « 0x01080004001b02840769 (10 bytes) 09:49:39.834 SERIAL » [ACK] (0x06) 09:49:39.835 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:49:39.837 CNTRLR « [Node 027] received wakeup notification 09:49:39.838 CNTRLR [Node 027] The node is now awake. 09:49:39.846 SERIAL » 0x010900131b02800225aaf1 (11 bytes) 09:49:39.847 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 170 └─[BatteryCCGet] 09:49:39.852 SERIAL « [ACK] (0x06) 09:49:39.855 SERIAL « 0x0104011301e8 (6 bytes) 09:49:39.855 SERIAL » [ACK] (0x06) 09:49:39.856 DRIVER « [RES] [SendData] was sent: true 09:49:39.876 SERIAL « 0x01070013aa00000342 (9 bytes) 09:49:39.876 SERIAL » [ACK] (0x06) 09:49:39.877 DRIVER « [REQ] [SendData] callback id: 170 transmit status: OK 09:49:39.886 SERIAL « 0x01090004001b038003640d (11 bytes) 09:49:39.892 CNTRLR [Node 027] [~] [Battery] level: 100 => 100 [Endpoint 0] 09:49:39.894 CNTRLR [Node 027] [~] [Battery] isLow: false => false [Endpoint 0] 09:49:39.894 SERIAL » [ACK] (0x06) 09:49:39.896 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 09:49:39.899 CNTRLR « [Node 027] received response for battery information: level: 100 09:49:39.899 CNTRLR [Node 027] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:49:39.967 CNTRLR [Node 027] WakeUpCC: doing a partial interview... 09:49:39.967 CNTRLR » [Node 027] retrieving wakeup interval from the device... 09:49:39.972 SERIAL » 0x010900131b02840525abf3 (11 bytes) 09:49:39.972 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 171 └─[WakeUpCCIntervalGet] 09:49:39.973 SERIAL « [ACK] (0x06) 09:49:39.980 SERIAL « 0x0104011301e8 (6 bytes) 09:49:39.980 SERIAL » [ACK] (0x06) 09:49:39.980 DRIVER « [RES] [SendData] was sent: true 09:49:39.997 SERIAL « 0x01070013ab00000242 (9 bytes) 09:49:39.997 SERIAL » [ACK] (0x06) 09:49:39.998 DRIVER « [REQ] [SendData] callback id: 171 transmit status: OK 09:49:40.008 SERIAL « 0x010c0004001b06840600038401ee (14 bytes) 09:49:40.009 CNTRLR [Node 027] [~] [Wake Up] wakeUpInterval: 900 => 900 [Endpoint 0] 09:49:40.009 CNTRLR [Node 027] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 09:49:40.010 SERIAL » [ACK] (0x06) 09:49:40.011 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 900 seconds controller node id: 1 09:49:40.012 CNTRLR « [Node 027] received wakeup configuration: wakeup interval: 900 seconds controller node: 1 09:49:40.012 CNTRLR [Node 027] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:49:40.013 CNTRLR [Node 027] AssociationCC: doing a partial interview... 09:49:40.013 CNTRLR [Node 027] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 09:49:40.013 CNTRLR [Node 027] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:49:40.014 CNTRLR [Node 027] BasicCC: doing a partial interview... 09:49:40.014 CNTRLR » [Node 027] querying Basic CC state... 09:49:40.020 SERIAL » 0x010900131b02200225ac57 (11 bytes) 09:49:40.020 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 172 └─[BasicCCGet] 09:49:40.023 SERIAL « [ACK] (0x06) 09:49:40.028 SERIAL « 0x0104011301e8 (6 bytes) 09:49:40.028 SERIAL » [ACK] (0x06) 09:49:40.029 DRIVER « [RES] [SendData] was sent: true 09:49:40.045 SERIAL « 0x01070013ac00000344 (9 bytes) 09:49:40.046 SERIAL » [ACK] (0x06) 09:49:40.046 DRIVER « [REQ] [SendData] callback id: 172 transmit status: OK 09:49:40.055 SERIAL « 0x01090004001b03200300c9 (11 bytes) 09:49:40.056 SERIAL » [ACK] (0x06) 09:49:40.056 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCReport] current value: 0 09:49:40.058 CNTRLR « [Node 027] received Basic CC state: current value: 0 09:49:40.058 CNTRLR [Node 027] [~] [Basic] interviewComplete: true => true [Endpoint 0] [internal] 09:49:40.059 CNTRLR [Node 027] BinarySensorCC: doing a partial interview... 09:49:40.059 CNTRLR » [Node 027] querying current value... 09:49:40.064 SERIAL » 0x010900131b02300225ad46 (11 bytes) 09:49:40.064 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 173 └─[BinarySensorCCGet] type: Any 09:49:40.065 SERIAL « [ACK] (0x06) 09:49:40.072 SERIAL « 0x0104011301e8 (6 bytes) 09:49:40.072 SERIAL » [ACK] (0x06) 09:49:40.072 DRIVER « [RES] [SendData] was sent: true 09:49:40.089 SERIAL « 0x01070013ad00000244 (9 bytes) 09:49:40.089 SERIAL » [ACK] (0x06) 09:49:40.089 DRIVER « [REQ] [SendData] callback id: 173 transmit status: OK 09:49:40.099 SERIAL « 0x01090004001b03300300d9 (11 bytes) 09:49:40.100 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:49:40.100 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:49:40.101 SERIAL » [ACK] (0x06) 09:49:40.102 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:49:40.103 CNTRLR « [Node 027] received current value: false 09:49:40.103 CNTRLR [Node 027] [~] [Binary Sensor] interviewComplete: true [Endpoint 0] [internal] => true 09:49:40.104 CNTRLR [Node 027] MultilevelSensorCC: doing a partial interview... 09:49:40.104 CNTRLR » [Node 027] querying Air temperature sensor reading... 09:49:40.108 SERIAL » 0x010b00131b043104010025ae47 (13 bytes) 09:49:40.109 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 174 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:49:40.110 SERIAL « [ACK] (0x06) 09:49:40.117 SERIAL « 0x0104011301e8 (6 bytes) 09:49:40.117 SERIAL » [ACK] (0x06) 09:49:40.117 DRIVER « [RES] [SendData] was sent: true 09:49:40.134 SERIAL « 0x01070013ae00000346 (9 bytes) 09:49:40.134 SERIAL » [ACK] (0x06) 09:49:40.135 DRIVER « [REQ] [SendData] callback id: 174 transmit status: OK 09:49:40.145 SERIAL « 0x010c0004001b063105012200d22f (14 bytes) 09:49:40.146 CNTRLR [Node 027] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 09:49:40.147 CNTRLR [Node 027] [~] [Multilevel Sensor] Air temperature: 21 => 21 [Endpoint 0] 09:49:40.147 SERIAL » [ACK] (0x06) 09:49:40.148 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 21 09:49:40.150 CNTRLR « [Node 027] received current Air temperature sensor reading: 21 °C 09:49:40.150 CNTRLR » [Node 027] querying Illuminance sensor reading... 09:49:40.156 SERIAL » 0x010b00131b043104030825af4c (13 bytes) 09:49:40.157 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 175 └─[MultilevelSensorCCGet] sensor type: Illuminance scale: Lux 09:49:40.159 SERIAL « [ACK] (0x06) 09:49:40.209 SERIAL « 0x0104011301e8 (6 bytes) 09:49:40.209 SERIAL » [ACK] (0x06) 09:49:40.210 DRIVER « [RES] [SendData] was sent: true 09:49:40.212 SERIAL « 0x01070013af00000246 (9 bytes) 09:49:40.212 SERIAL » [ACK] (0x06) 09:49:40.213 DRIVER « [REQ] [SendData] callback id: 175 transmit status: OK 09:49:40.215 SERIAL « 0x010c0004001b063105030a002afd (14 bytes) 09:49:40.216 CNTRLR [Node 027] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 09:49:40.216 CNTRLR [Node 027] [~] [Multilevel Sensor] Illuminance: 19 => 42 [Endpoint 0] 09:49:40.217 SERIAL » [ACK] (0x06) 09:49:40.218 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 42 09:49:40.219 CNTRLR « [Node 027] received current Illuminance sensor reading: 42 Lux 09:49:40.219 CNTRLR [Node 027] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 09:49:40.220 CNTRLR [Node 027] ConfigurationCC: Loading configuration parameters from device confi g 09:49:40.226 CNTRLR [Node 027] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:49:40.227 CNTRLR [Node 027] [Configuration] 1: metadata updated 09:49:40.228 CNTRLR [Node 027] [Configuration] 2: metadata updated 09:49:40.229 CNTRLR [Node 027] [Configuration] 3: metadata updated 09:49:40.230 CNTRLR [Node 027] [Configuration] 4: metadata updated 09:49:40.231 CNTRLR [Node 027] [Configuration] 6: metadata updated 09:49:40.232 CNTRLR [Node 027] [Configuration] 8: metadata updated 09:49:40.233 CNTRLR [Node 027] [Configuration] 9: metadata updated 09:49:40.235 CNTRLR [Node 027] [Configuration] 12: metadata updated 09:49:40.236 CNTRLR [Node 027] [Configuration] 14: metadata updated 09:49:40.237 CNTRLR [Node 027] [Configuration] 16: metadata updated 09:49:40.238 CNTRLR [Node 027] [Configuration] 20: metadata updated 09:49:40.239 CNTRLR [Node 027] [Configuration] 22: metadata updated 09:49:40.241 CNTRLR [Node 027] [Configuration] 24: metadata updated 09:49:40.242 CNTRLR [Node 027] [Configuration] 26: metadata updated 09:49:40.244 CNTRLR [Node 027] [Configuration] 40: metadata updated 09:49:40.245 CNTRLR [Node 027] [Configuration] 42: metadata updated 09:49:40.249 CNTRLR [Node 027] [Configuration] 60: metadata updated 09:49:40.250 CNTRLR [Node 027] [Configuration] 62: metadata updated 09:49:40.251 CNTRLR [Node 027] [Configuration] 64: metadata updated 09:49:40.253 CNTRLR [Node 027] [Configuration] 66: metadata updated 09:49:40.254 CNTRLR [Node 027] [Configuration] 80: metadata updated 09:49:40.255 CNTRLR [Node 027] [Configuration] 81: metadata updated 09:49:40.256 CNTRLR [Node 027] [Configuration] 82: metadata updated 09:49:40.258 CNTRLR [Node 027] [Configuration] 83: metadata updated 09:49:40.259 CNTRLR [Node 027] [Configuration] 86: metadata updated 09:49:40.260 CNTRLR [Node 027] [Configuration] 87: metadata updated 09:49:40.261 CNTRLR [Node 027] [Configuration] 89: metadata updated 09:49:40.262 CNTRLR [Node 027] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:49:40.263 CNTRLR » [Node 027] querying parameter #1 value... 09:49:40.267 SERIAL » 0x010a00131b0370050125b01f (12 bytes) 09:49:40.267 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 176 └─[ConfigurationCCGet] parameter #: 1 09:49:40.274 SERIAL « [ACK] (0x06) 09:49:40.277 SERIAL « 0x0104011301e8 (6 bytes) 09:49:40.278 SERIAL » [ACK] (0x06) 09:49:40.284 DRIVER « [RES] [SendData] was sent: true 09:49:40.298 SERIAL « 0x01070013b000000259 (9 bytes) 09:49:40.298 SERIAL » [ACK] (0x06) 09:49:40.301 DRIVER « [REQ] [SendData] callback id: 176 transmit status: OK 09:49:40.309 SERIAL « 0x010b0004001b05700601010a92 (13 bytes) 09:49:40.315 CNTRLR [Node 027] [~] [Configuration] 1: 10 => 10 09:49:40.316 SERIAL » [ACK] (0x06) 09:49:40.319 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 10 09:49:40.321 CNTRLR « [Node 027] parameter #1 has value: 10 09:49:40.321 CNTRLR » [Node 027] querying parameter #2 value... 09:49:40.326 SERIAL » 0x010a00131b0370050225b11d (12 bytes) 09:49:40.327 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 177 └─[ConfigurationCCGet] parameter #: 2 09:49:40.335 SERIAL « [ACK] (0x06) 09:49:40.337 SERIAL « 0x0104011301e8 (6 bytes) 09:49:40.337 SERIAL » [ACK] (0x06) 09:49:40.338 DRIVER « [RES] [SendData] was sent: true 09:49:40.352 SERIAL « 0x01070013b100000258 (9 bytes) 09:49:40.352 SERIAL » [ACK] (0x06) 09:49:40.353 DRIVER « [REQ] [SendData] callback id: 177 transmit status: OK 09:49:40.363 SERIAL « 0x010b0004001b05700602010f94 (13 bytes) 09:49:40.368 CNTRLR [Node 027] [~] [Configuration] 2: 15 => 15 09:49:40.369 SERIAL » [ACK] (0x06) 09:49:40.370 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 15 09:49:40.371 CNTRLR « [Node 027] parameter #2 has value: 15 09:49:40.372 CNTRLR » [Node 027] querying parameter #3 value... 09:49:40.376 SERIAL » 0x010a00131b0370050325b21f (12 bytes) 09:49:40.376 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 178 └─[ConfigurationCCGet] parameter #: 3 09:49:40.433 SERIAL « [ACK] (0x06) 09:49:40.435 SERIAL « 0x0104011301e8 (6 bytes) 09:49:40.435 SERIAL » [ACK] (0x06) 09:49:40.437 DRIVER « [RES] [SendData] was sent: true 09:49:40.440 SERIAL « 0x01070013b20000025b (9 bytes) 09:49:40.441 SERIAL » [ACK] (0x06) 09:49:40.442 DRIVER « [REQ] [SendData] callback id: 178 transmit status: OK 09:49:40.445 SERIAL « 0x010b0004001b0570060301019b (13 bytes) 09:49:40.450 CNTRLR [Node 027] [~] [Configuration] 3: 1 => 1 09:49:40.451 SERIAL » [ACK] (0x06) 09:49:40.452 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 1 09:49:40.459 CNTRLR « [Node 027] parameter #3 has value: 1 09:49:40.459 CNTRLR » [Node 027] querying parameter #4 value... 09:49:40.468 SERIAL » 0x010a00131b0370050425b319 (12 bytes) 09:49:40.469 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 179 └─[ConfigurationCCGet] parameter #: 4 09:49:40.472 SERIAL « [ACK] (0x06) 09:49:40.477 SERIAL « 0x0104011301e8 (6 bytes) 09:49:40.478 SERIAL » [ACK] (0x06) 09:49:40.479 DRIVER « [RES] [SendData] was sent: true 09:49:40.494 SERIAL « 0x01070013b30000025a (9 bytes) 09:49:40.494 SERIAL » [ACK] (0x06) 09:49:40.495 DRIVER « [REQ] [SendData] callback id: 179 transmit status: OK 09:49:40.505 SERIAL « 0x010b0004001b0570060401029f (13 bytes) 09:49:40.509 CNTRLR [Node 027] [~] [Configuration] 4: 2 => 2 09:49:40.510 SERIAL » [ACK] (0x06) 09:49:40.511 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 1 value: 2 09:49:40.512 CNTRLR « [Node 027] parameter #4 has value: 2 09:49:40.512 CNTRLR » [Node 027] querying parameter #6 value... 09:49:40.516 SERIAL » 0x010a00131b0370050625b41c (12 bytes) 09:49:40.516 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 180 └─[ConfigurationCCGet] parameter #: 6 09:49:40.521 SERIAL « [ACK] (0x06) 09:49:40.524 SERIAL « 0x0104011301e8 (6 bytes) 09:49:40.525 SERIAL » [ACK] (0x06) 09:49:40.525 DRIVER « [RES] [SendData] was sent: true 09:49:40.542 SERIAL « 0x01070013b40000025d (9 bytes) 09:49:40.542 SERIAL » [ACK] (0x06) 09:49:40.542 DRIVER « [REQ] [SendData] callback id: 180 transmit status: OK 09:49:40.553 SERIAL « 0x010c0004001b0670060602001e86 (14 bytes) 09:49:40.558 CNTRLR [Node 027] [~] [Configuration] 6: 30 => 30 09:49:40.558 SERIAL » [ACK] (0x06) 09:49:40.559 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 2 value: 30 09:49:40.561 CNTRLR « [Node 027] parameter #6 has value: 30 09:49:40.561 CNTRLR » [Node 027] querying parameter #8 value... 09:49:40.565 SERIAL » 0x010a00131b0370050825b513 (12 bytes) 09:49:40.566 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 181 └─[ConfigurationCCGet] parameter #: 8 09:49:40.570 SERIAL « [ACK] (0x06) 09:49:40.574 SERIAL « 0x0104011301e8 (6 bytes) 09:49:40.574 SERIAL » [ACK] (0x06) 09:49:40.575 DRIVER « [RES] [SendData] was sent: true 09:49:40.591 SERIAL « 0x01070013b50000025c (9 bytes) 09:49:40.591 SERIAL » [ACK] (0x06) 09:49:40.592 DRIVER « [REQ] [SendData] callback id: 181 transmit status: OK 09:49:40.602 SERIAL « 0x010b0004001b05700608010091 (13 bytes) 09:49:40.607 CNTRLR [Node 027] [~] [Configuration] 8: 0 => 0 09:49:40.608 SERIAL » [ACK] (0x06) 09:49:40.608 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 0 09:49:40.610 CNTRLR « [Node 027] parameter #8 has value: 0 09:49:40.610 CNTRLR » [Node 027] querying parameter #9 value... 09:49:40.613 SERIAL » 0x010a00131b0370050925b611 (12 bytes) 09:49:40.614 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 182 └─[ConfigurationCCGet] parameter #: 9 09:49:40.616 SERIAL « [ACK] (0x06) 09:49:40.621 SERIAL « 0x0104011301e8 (6 bytes) 09:49:40.622 SERIAL » [ACK] (0x06) 09:49:40.622 DRIVER « [RES] [SendData] was sent: true 09:49:40.639 SERIAL « 0x01070013b60000025f (9 bytes) 09:49:40.639 SERIAL » [ACK] (0x06) 09:49:40.639 DRIVER « [REQ] [SendData] callback id: 182 transmit status: OK 09:49:40.651 SERIAL « 0x010c0004001b06700609020028bf (14 bytes) 09:49:40.656 CNTRLR [Node 027] [~] [Configuration] 9: 40 => 40 09:49:40.657 SERIAL » [ACK] (0x06) 09:49:40.658 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 2 value: 40 09:49:40.661 CNTRLR « [Node 027] parameter #9 has value: 40 09:49:40.661 CNTRLR » [Node 027] querying parameter #12 value... 09:49:40.665 SERIAL » 0x010a00131b0370050c25b715 (12 bytes) 09:49:40.666 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 183 └─[ConfigurationCCGet] parameter #: 12 09:49:40.669 SERIAL « [ACK] (0x06) 09:49:40.675 SERIAL « 0x0104011301e8 (6 bytes) 09:49:40.675 SERIAL » [ACK] (0x06) 09:49:40.676 DRIVER « [RES] [SendData] was sent: true 09:49:40.691 SERIAL « 0x01070013b70000025e (9 bytes) 09:49:40.691 SERIAL » [ACK] (0x06) 09:49:40.691 DRIVER « [REQ] [SendData] callback id: 183 transmit status: OK 09:49:40.701 SERIAL « 0x010b0004001b0570060c010095 (13 bytes) 09:49:40.706 CNTRLR [Node 027] [~] [Configuration] 12: 0 => 0 09:49:40.707 SERIAL » [ACK] (0x06) 09:49:40.708 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 1 value: 0 09:49:40.709 CNTRLR « [Node 027] parameter #12 has value: 0 09:49:40.709 CNTRLR » [Node 027] querying parameter #14 value... 09:49:40.715 SERIAL » 0x010a00131b0370050e25b818 (12 bytes) 09:49:40.716 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 184 └─[ConfigurationCCGet] parameter #: 14 09:49:40.718 SERIAL « [ACK] (0x06) 09:49:40.723 SERIAL « 0x0104011301e8 (6 bytes) 09:49:40.724 SERIAL » [ACK] (0x06) 09:49:40.724 DRIVER « [RES] [SendData] was sent: true 09:49:40.740 SERIAL « 0x01070013b800000251 (9 bytes) 09:49:40.741 SERIAL » [ACK] (0x06) 09:49:40.741 DRIVER « [REQ] [SendData] callback id: 184 transmit status: OK 09:49:40.751 SERIAL « 0x010b0004001b0570060e01ff68 (13 bytes) 09:49:40.756 CNTRLR [Node 027] [~] [Configuration] 14: 255 => 255 09:49:40.757 SERIAL » [ACK] (0x06) 09:49:40.758 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 255 09:49:40.759 CNTRLR « [Node 027] parameter #14 has value: 255 09:49:40.759 CNTRLR » [Node 027] querying parameter #16 value... 09:49:40.763 SERIAL » 0x010a00131b0370051025b907 (12 bytes) 09:49:40.763 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 185 └─[ConfigurationCCGet] parameter #: 16 09:49:40.766 SERIAL « [ACK] (0x06) 09:49:40.772 SERIAL « 0x0104011301e8 (6 bytes) 09:49:40.772 SERIAL » [ACK] (0x06) 09:49:40.776 DRIVER « [RES] [SendData] was sent: true 09:49:40.788 SERIAL « 0x01070013b900000250 (9 bytes) 09:49:40.789 SERIAL » [ACK] (0x06) 09:49:40.789 DRIVER « [REQ] [SendData] callback id: 185 transmit status: OK 09:49:40.799 SERIAL « 0x010b0004001b05700610010089 (13 bytes) 09:49:40.804 CNTRLR [Node 027] [~] [Configuration] 16: 0 => 0 09:49:40.806 SERIAL » [ACK] (0x06) 09:49:40.806 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 0 09:49:40.808 CNTRLR « [Node 027] parameter #16 has value: 0 09:49:40.808 CNTRLR » [Node 027] querying parameter #20 value... 09:49:40.818 SERIAL » 0x010a00131b0370051425ba00 (12 bytes) 09:49:40.819 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 186 └─[ConfigurationCCGet] parameter #: 20 09:49:40.825 SERIAL « [ACK] (0x06) 09:49:40.827 SERIAL « 0x0104011301e8 (6 bytes) 09:49:40.828 SERIAL » [ACK] (0x06) 09:49:40.828 DRIVER « [RES] [SendData] was sent: true 09:49:40.844 SERIAL « 0x01070013ba00000253 (9 bytes) 09:49:40.844 SERIAL » [ACK] (0x06) 09:49:40.845 DRIVER « [REQ] [SendData] callback id: 186 transmit status: OK 09:49:40.854 SERIAL « 0x010b0004001b05700614010f82 (13 bytes) 09:49:40.860 CNTRLR [Node 027] [~] [Configuration] 20: 15 => 15 09:49:40.861 SERIAL » [ACK] (0x06) 09:49:40.861 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 15 09:49:40.865 CNTRLR « [Node 027] parameter #20 has value: 15 09:49:40.866 CNTRLR » [Node 027] querying parameter #22 value... 09:49:40.870 SERIAL » 0x010a00131b0370051625bb03 (12 bytes) 09:49:40.870 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 187 └─[ConfigurationCCGet] parameter #: 22 09:49:40.875 SERIAL « [ACK] (0x06) 09:49:40.880 SERIAL « 0x0104011301e8 (6 bytes) 09:49:40.880 SERIAL » [ACK] (0x06) 09:49:40.881 DRIVER « [RES] [SendData] was sent: true 09:49:40.896 SERIAL « 0x01070013bb00000353 (9 bytes) 09:49:40.896 SERIAL » [ACK] (0x06) 09:49:40.896 DRIVER « [REQ] [SendData] callback id: 187 transmit status: OK 09:49:40.906 SERIAL « 0x010c0004001b0670061602001e96 (14 bytes) 09:49:40.911 CNTRLR [Node 027] [~] [Configuration] 22: 30 => 30 09:49:40.912 SERIAL » [ACK] (0x06) 09:49:40.913 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 30 09:49:40.914 CNTRLR « [Node 027] parameter #22 has value: 30 09:49:40.914 CNTRLR » [Node 027] querying parameter #24 value... 09:49:40.918 SERIAL » 0x010a00131b0370051825bc0a (12 bytes) 09:49:40.919 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 188 └─[ConfigurationCCGet] parameter #: 24 09:49:40.921 SERIAL « [ACK] (0x06) 09:49:40.927 SERIAL « 0x0104011301e8 (6 bytes) 09:49:40.928 SERIAL » [ACK] (0x06) 09:49:40.928 DRIVER « [RES] [SendData] was sent: true 09:49:40.944 SERIAL « 0x01070013bc00000255 (9 bytes) 09:49:40.944 SERIAL » [ACK] (0x06) 09:49:40.945 DRIVER « [REQ] [SendData] callback id: 188 transmit status: OK 09:49:40.955 SERIAL « 0x010b0004001b05700618010081 (13 bytes) 09:49:40.960 CNTRLR [Node 027] [~] [Configuration] 24: 0 => 0 09:49:40.961 SERIAL » [ACK] (0x06) 09:49:40.962 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 24 value size: 1 value: 0 09:49:40.963 CNTRLR « [Node 027] parameter #24 has value: 0 09:49:40.963 CNTRLR » [Node 027] querying parameter #26 value... 09:49:40.967 SERIAL » 0x010a00131b0370051a25bd09 (12 bytes) 09:49:40.968 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 189 └─[ConfigurationCCGet] parameter #: 26 09:49:40.973 SERIAL « [ACK] (0x06) 09:49:40.976 SERIAL « 0x0104011301e8 (6 bytes) 09:49:40.976 SERIAL » [ACK] (0x06) 09:49:40.976 DRIVER « [RES] [SendData] was sent: true 09:49:40.993 SERIAL « 0x01070013bd00000254 (9 bytes) 09:49:40.993 SERIAL » [ACK] (0x06) 09:49:40.994 DRIVER « [REQ] [SendData] callback id: 189 transmit status: OK 09:49:41.004 SERIAL « 0x010b0004001b0570061a010083 (13 bytes) 09:49:41.008 CNTRLR [Node 027] [~] [Configuration] 26: 0 => 0 09:49:41.009 SERIAL » [ACK] (0x06) 09:49:41.010 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 26 value size: 1 value: 0 09:49:41.011 CNTRLR « [Node 027] parameter #26 has value: 0 09:49:41.011 CNTRLR » [Node 027] querying parameter #40 value... 09:49:41.016 SERIAL » 0x010a00131b0370052825be38 (12 bytes) 09:49:41.017 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 190 └─[ConfigurationCCGet] parameter #: 40 09:49:41.021 SERIAL « [ACK] (0x06) 09:49:41.025 SERIAL « 0x0104011301e8 (6 bytes) 09:49:41.025 SERIAL » [ACK] (0x06) 09:49:41.026 DRIVER « [RES] [SendData] was sent: true 09:49:41.042 SERIAL « 0x01070013be00000257 (9 bytes) 09:49:41.042 SERIAL » [ACK] (0x06) 09:49:41.043 DRIVER « [REQ] [SendData] callback id: 190 transmit status: OK 09:49:41.053 SERIAL « 0x010c0004001b067006280200c87e (14 bytes) 09:49:41.058 CNTRLR [Node 027] [~] [Configuration] 40: 200 => 200 09:49:41.059 SERIAL » [ACK] (0x06) 09:49:41.059 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 2 value: 200 09:49:41.061 CNTRLR « [Node 027] parameter #40 has value: 200 09:49:41.061 CNTRLR » [Node 027] querying parameter #42 value... 09:49:41.065 SERIAL » 0x010a00131b0370052a25bf3b (12 bytes) 09:49:41.065 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 191 └─[ConfigurationCCGet] parameter #: 42 09:49:41.071 SERIAL « [ACK] (0x06) 09:49:41.074 SERIAL « 0x0104011301e8 (6 bytes) 09:49:41.075 SERIAL » [ACK] (0x06) 09:49:41.076 DRIVER « [RES] [SendData] was sent: true 09:49:41.090 SERIAL « 0x01070013bf00000256 (9 bytes) 09:49:41.090 SERIAL » [ACK] (0x06) 09:49:41.091 DRIVER « [REQ] [SendData] callback id: 191 transmit status: OK 09:49:41.101 SERIAL « 0x010c0004001b0670062a020000b4 (14 bytes) 09:49:41.106 CNTRLR [Node 027] [~] [Configuration] 42: 0 => 0 09:49:41.106 SERIAL » [ACK] (0x06) 09:49:41.107 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 0 09:49:41.111 CNTRLR « [Node 027] parameter #42 has value: 0 09:49:41.111 CNTRLR » [Node 027] querying parameter #60 value... 09:49:41.118 SERIAL » 0x010a00131b0370053c25c052 (12 bytes) 09:49:41.119 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 192 └─[ConfigurationCCGet] parameter #: 60 09:49:41.121 SERIAL « [ACK] (0x06) 09:49:41.127 SERIAL « 0x0104011301e8 (6 bytes) 09:49:41.127 SERIAL » [ACK] (0x06) 09:49:41.128 DRIVER « [RES] [SendData] was sent: true 09:49:41.144 SERIAL « 0x01070013c000000229 (9 bytes) 09:49:41.144 SERIAL » [ACK] (0x06) 09:49:41.145 DRIVER « [REQ] [SendData] callback id: 192 transmit status: OK 09:49:41.155 SERIAL « 0x010b0004001b0570063c010aaf (13 bytes) 09:49:41.159 CNTRLR [Node 027] [~] [Configuration] 60: 10 => 10 09:49:41.160 SERIAL » [ACK] (0x06) 09:49:41.161 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 1 value: 10 09:49:41.162 CNTRLR « [Node 027] parameter #60 has value: 10 09:49:41.162 CNTRLR » [Node 027] querying parameter #62 value... 09:49:41.166 SERIAL » 0x010a00131b0370053e25c151 (12 bytes) 09:49:41.166 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 193 └─[ConfigurationCCGet] parameter #: 62 09:49:41.170 SERIAL « [ACK] (0x06) 09:49:41.175 SERIAL « 0x0104011301e8 (6 bytes) 09:49:41.175 SERIAL » [ACK] (0x06) 09:49:41.176 DRIVER « [RES] [SendData] was sent: true 09:49:41.191 SERIAL « 0x01070013c100000228 (9 bytes) 09:49:41.192 SERIAL » [ACK] (0x06) 09:49:41.192 DRIVER « [REQ] [SendData] callback id: 193 transmit status: OK 09:49:41.203 SERIAL « 0x010c0004001b0670063e02038427 (14 bytes) 09:49:41.207 CNTRLR [Node 027] [~] [Configuration] 62: 900 => 900 09:49:41.208 SERIAL » [ACK] (0x06) 09:49:41.209 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 62 value size: 2 value: 900 09:49:41.210 CNTRLR « [Node 027] parameter #62 has value: 900 09:49:41.210 CNTRLR » [Node 027] querying parameter #64 value... 09:49:41.214 SERIAL » 0x010a00131b0370054025c22c (12 bytes) 09:49:41.214 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 194 └─[ConfigurationCCGet] parameter #: 64 09:49:41.217 SERIAL « [ACK] (0x06) 09:49:41.222 SERIAL « 0x0104011301e8 (6 bytes) 09:49:41.222 SERIAL » [ACK] (0x06) 09:49:41.223 DRIVER « [RES] [SendData] was sent: true 09:49:41.239 SERIAL « 0x01070013c20000022b (9 bytes) 09:49:41.240 SERIAL » [ACK] (0x06) 09:49:41.240 DRIVER « [REQ] [SendData] callback id: 194 transmit status: OK 09:49:41.250 SERIAL « 0x010c0004001b06700640020000de (14 bytes) 09:49:41.255 CNTRLR [Node 027] [~] [Configuration] 64: 0 => 0 09:49:41.257 SERIAL » [ACK] (0x06) 09:49:41.258 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 64 value size: 2 value: 0 09:49:41.259 CNTRLR « [Node 027] parameter #64 has value: 0 09:49:41.259 CNTRLR » [Node 027] querying parameter #66 value... 09:49:41.264 SERIAL » 0x010a00131b0370054225c32f (12 bytes) 09:49:41.265 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 195 └─[ConfigurationCCGet] parameter #: 66 09:49:41.271 SERIAL « [ACK] (0x06) 09:49:41.276 SERIAL « 0x0104011301e8 (6 bytes) 09:49:41.276 SERIAL » [ACK] (0x06) 09:49:41.277 DRIVER « [RES] [SendData] was sent: true 09:49:41.290 SERIAL « 0x01070013c30000022a (9 bytes) 09:49:41.290 SERIAL » [ACK] (0x06) 09:49:41.291 DRIVER « [REQ] [SendData] callback id: 195 transmit status: OK 09:49:41.301 SERIAL « 0x010c0004001b06700642020000dc (14 bytes) 09:49:41.306 CNTRLR [Node 027] [~] [Configuration] 66: 0 => 0 09:49:41.306 SERIAL » [ACK] (0x06) 09:49:41.307 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 66 value size: 2 value: 0 09:49:41.308 CNTRLR « [Node 027] parameter #66 has value: 0 09:49:41.308 CNTRLR » [Node 027] querying parameter #80 value... 09:49:41.312 SERIAL » 0x010a00131b0370055025c43a (12 bytes) 09:49:41.313 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 196 └─[ConfigurationCCGet] parameter #: 80 09:49:41.315 SERIAL « [ACK] (0x06) 09:49:41.321 SERIAL « 0x0104011301e8 (6 bytes) 09:49:41.321 SERIAL » [ACK] (0x06) 09:49:41.321 DRIVER « [RES] [SendData] was sent: true 09:49:41.338 SERIAL « 0x01070013c40000022d (9 bytes) 09:49:41.338 SERIAL » [ACK] (0x06) 09:49:41.338 DRIVER « [REQ] [SendData] callback id: 196 transmit status: OK 09:49:41.348 SERIAL « 0x010b0004001b057006500100c9 (13 bytes) 09:49:41.353 CNTRLR [Node 027] [~] [Configuration] 80: 0 => 0 09:49:41.354 SERIAL » [ACK] (0x06) 09:49:41.355 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 80 value size: 1 value: 0 09:49:41.356 CNTRLR « [Node 027] parameter #80 has value: 0 09:49:41.357 CNTRLR » [Node 027] querying parameter #81 value... 09:49:41.366 SERIAL » 0x010a00131b0370055125c53a (12 bytes) 09:49:41.366 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 197 └─[ConfigurationCCGet] parameter #: 81 09:49:41.371 SERIAL « [ACK] (0x06) 09:49:41.376 SERIAL « 0x0104011301e8 (6 bytes) 09:49:41.378 SERIAL » [ACK] (0x06) 09:49:41.379 DRIVER « [RES] [SendData] was sent: true 09:49:41.391 SERIAL « 0x01070013c50000022c (9 bytes) 09:49:41.391 SERIAL » [ACK] (0x06) 09:49:41.392 DRIVER « [REQ] [SendData] callback id: 197 transmit status: OK 09:49:41.402 SERIAL « 0x010b0004001b057006510132fa (13 bytes) 09:49:41.409 CNTRLR [Node 027] [~] [Configuration] 81: 50 => 50 09:49:41.410 SERIAL » [ACK] (0x06) 09:49:41.411 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 81 value size: 1 value: 50 09:49:41.412 CNTRLR « [Node 027] parameter #81 has value: 50 09:49:41.413 CNTRLR » [Node 027] querying parameter #82 value... 09:49:41.418 SERIAL » 0x010a00131b0370055225c63a (12 bytes) 09:49:41.418 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 198 └─[ConfigurationCCGet] parameter #: 82 09:49:41.421 SERIAL « [ACK] (0x06) 09:49:41.426 SERIAL « 0x0104011301e8 (6 bytes) 09:49:41.427 SERIAL » [ACK] (0x06) 09:49:41.427 DRIVER « [RES] [SendData] was sent: true 09:49:41.443 SERIAL « 0x01070013c60000022f (9 bytes) 09:49:41.444 SERIAL » [ACK] (0x06) 09:49:41.444 DRIVER « [REQ] [SendData] callback id: 198 transmit status: OK 09:49:41.454 SERIAL « 0x010c0004001b06700652020064a8 (14 bytes) 09:49:41.461 CNTRLR [Node 027] [~] [Configuration] 82: 100 => 100 09:49:41.462 SERIAL » [ACK] (0x06) 09:49:41.463 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 82 value size: 2 value: 100 09:49:41.465 CNTRLR « [Node 027] parameter #82 has value: 100 09:49:41.465 CNTRLR » [Node 027] querying parameter #83 value... 09:49:41.468 SERIAL » 0x010a00131b0370055325c73a (12 bytes) 09:49:41.469 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 199 └─[ConfigurationCCGet] parameter #: 83 09:49:41.472 SERIAL « [ACK] (0x06) 09:49:41.477 SERIAL « 0x0104011301e8 (6 bytes) 09:49:41.477 SERIAL » [ACK] (0x06) 09:49:41.478 DRIVER « [RES] [SendData] was sent: true 09:49:41.494 SERIAL « 0x01070013c70000022e (9 bytes) 09:49:41.494 SERIAL » [ACK] (0x06) 09:49:41.495 DRIVER « [REQ] [SendData] callback id: 199 transmit status: OK 09:49:41.505 SERIAL « 0x010c0004001b067006530203e826 (14 bytes) 09:49:41.512 CNTRLR [Node 027] [~] [Configuration] 83: 1000 => 1000 09:49:41.513 SERIAL » [ACK] (0x06) 09:49:41.514 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 83 value size: 2 value: 1000 09:49:41.515 CNTRLR « [Node 027] parameter #83 has value: 1000 09:49:41.515 CNTRLR » [Node 027] querying parameter #86 value... 09:49:41.519 SERIAL » 0x010a00131b0370055625c830 (12 bytes) 09:49:41.519 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 200 └─[ConfigurationCCGet] parameter #: 86 09:49:41.522 SERIAL « [ACK] (0x06) 09:49:41.527 SERIAL « 0x0104011301e8 (6 bytes) 09:49:41.527 SERIAL » [ACK] (0x06) 09:49:41.528 DRIVER « [RES] [SendData] was sent: true 09:49:41.544 SERIAL « 0x01070013c800000320 (9 bytes) 09:49:41.544 SERIAL » [ACK] (0x06) 09:49:41.545 DRIVER « [REQ] [SendData] callback id: 200 transmit status: OK 09:49:41.555 SERIAL « 0x010b0004001b057006560112dd (13 bytes) 09:49:41.560 CNTRLR [Node 027] [~] [Configuration] 86: 18 => 18 09:49:41.561 SERIAL » [ACK] (0x06) 09:49:41.561 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 86 value size: 1 value: 18 09:49:41.563 CNTRLR « [Node 027] parameter #86 has value: 18 09:49:41.563 CNTRLR » [Node 027] querying parameter #87 value... 09:49:41.566 SERIAL » 0x010a00131b0370055725c930 (12 bytes) 09:49:41.567 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 201 └─[ConfigurationCCGet] parameter #: 87 09:49:41.571 SERIAL « [ACK] (0x06) 09:49:41.576 SERIAL « 0x0104011301e8 (6 bytes) 09:49:41.576 SERIAL » [ACK] (0x06) 09:49:41.577 DRIVER « [RES] [SendData] was sent: true 09:49:41.592 SERIAL « 0x01070013c900000220 (9 bytes) 09:49:41.592 SERIAL » [ACK] (0x06) 09:49:41.592 DRIVER « [REQ] [SendData] callback id: 201 transmit status: OK 09:49:41.602 SERIAL « 0x010b0004001b05700657011cd2 (13 bytes) 09:49:41.607 CNTRLR [Node 027] [~] [Configuration] 87: 28 => 28 09:49:41.608 SERIAL » [ACK] (0x06) 09:49:41.609 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 87 value size: 1 value: 28 09:49:41.610 CNTRLR « [Node 027] parameter #87 has value: 28 09:49:41.610 CNTRLR » [Node 027] querying parameter #89 value... 09:49:41.614 SERIAL » 0x010a00131b0370055925ca3d (12 bytes) 09:49:41.614 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 202 └─[ConfigurationCCGet] parameter #: 89 09:49:41.616 SERIAL « [ACK] (0x06) 09:49:41.622 SERIAL « 0x0104011301e8 (6 bytes) 09:49:41.622 SERIAL » [ACK] (0x06) 09:49:41.623 DRIVER « [RES] [SendData] was sent: true 09:49:41.639 SERIAL « 0x01070013ca00000223 (9 bytes) 09:49:41.639 SERIAL » [ACK] (0x06) 09:49:41.640 DRIVER « [REQ] [SendData] callback id: 202 transmit status: OK 09:49:41.650 SERIAL « 0x010b0004001b057006590101c1 (13 bytes) 09:49:41.655 CNTRLR [Node 027] [~] [Configuration] 89: 1 => 1 09:49:41.655 SERIAL » [ACK] (0x06) 09:49:41.656 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 89 value size: 1 value: 1 09:49:41.657 CNTRLR « [Node 027] parameter #89 has value: 1 09:49:41.658 CNTRLR [Node 027] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 09:49:41.702 CNTRLR [Node 027] AlarmSensorCC: doing a partial interview... 09:49:41.703 CNTRLR » [Node 027] querying current value for General Purpose... 09:49:41.707 SERIAL » 0x010a00131b039c010025cb8d (12 bytes) 09:49:41.707 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 203 └─[AlarmSensorCCGet] sensor type: General Purpose 09:49:41.709 SERIAL « [ACK] (0x06) 09:49:41.715 SERIAL « 0x0104011301e8 (6 bytes) 09:49:41.715 SERIAL » [ACK] (0x06) 09:49:41.715 DRIVER « [RES] [SendData] was sent: true 09:49:41.732 SERIAL « 0x01070013cb00000222 (9 bytes) 09:49:41.732 SERIAL » [ACK] (0x06) 09:49:41.733 DRIVER « [REQ] [SendData] callback id: 203 transmit status: OK 09:49:41.744 SERIAL « 0x010d0004001b079c021b000000006f (15 bytes) 09:49:41.745 CNTRLR [Node 027] [~] [Alarm Sensor] state[0]: false => false [Endpoint 0] 09:49:41.746 CNTRLR [Node 027] [+] [Alarm Sensor] severity[0]: undefined [Endpoint 0] 09:49:41.746 CNTRLR [Node 027] [+] [Alarm Sensor] duration[0]: undefined [Endpoint 0] 09:49:41.747 SERIAL » [ACK] (0x06) 09:49:41.748 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: false 09:49:41.749 CNTRLR « [Node 027] received current value for General Purpose: state: false 09:49:41.749 CNTRLR [Node 027] [~] [Alarm Sensor] interviewComplete: true [Endpoint 0] [internal] => true 09:49:41.750 CNTRLR [Node 027] MultiChannelAssociationCC: doing a partial interview... 09:49:41.750 CNTRLR » [Node 027] querying multi channel association group #1... 09:49:41.754 SERIAL » 0x010a00131b038e020125cc9a (12 bytes) 09:49:41.754 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 204 └─[MultiChannelAssociationCCGet] group id: 1 09:49:41.757 SERIAL « [ACK] (0x06) 09:49:41.762 SERIAL « 0x0104011301e8 (6 bytes) 09:49:41.762 SERIAL » [ACK] (0x06) 09:49:41.763 DRIVER « [RES] [SendData] was sent: true 09:49:41.779 SERIAL « 0x01070013cc00000225 (9 bytes) 09:49:41.779 SERIAL » [ACK] (0x06) 09:49:41.780 DRIVER « [REQ] [SendData] callback id: 204 transmit status: OK 09:49:41.790 SERIAL « 0x010c0004001b068e030105000162 (14 bytes) 09:49:41.791 SERIAL » [ACK] (0x06) 09:49:41.792 CNTRLR [Node 027] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 09:49:41.793 CNTRLR [Node 027] [~] [Multi Channel Association] nodeIds[1]: 1 => 1 09:49:41.794 CNTRLR [Node 027] [~] [Multi Channel Association] endpoints[1]: => 09:49:41.794 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: 1 endpoints: 09:49:41.796 CNTRLR « [Node 027] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 09:49:41.796 CNTRLR » [Node 027] querying multi channel association group #2... 09:49:41.800 SERIAL » 0x010a00131b038e020225cd98 (12 bytes) 09:49:41.800 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 205 └─[MultiChannelAssociationCCGet] group id: 2 09:49:41.802 SERIAL « [ACK] (0x06) 09:49:41.810 SERIAL « 0x0104011301e8 (6 bytes) 09:49:41.811 SERIAL » [ACK] (0x06) 09:49:41.812 DRIVER « [RES] [SendData] was sent: true 09:49:41.825 SERIAL « 0x01070013cd00000325 (9 bytes) 09:49:41.825 SERIAL » [ACK] (0x06) 09:49:41.826 DRIVER « [REQ] [SendData] callback id: 205 transmit status: OK 09:49:41.836 SERIAL « 0x010c0004001b068e030205000161 (14 bytes) 09:49:41.837 SERIAL » [ACK] (0x06) 09:49:41.837 CNTRLR [Node 027] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 09:49:41.838 CNTRLR [Node 027] [~] [Multi Channel Association] nodeIds[2]: 1 => 1 09:49:41.839 CNTRLR [Node 027] [~] [Multi Channel Association] endpoints[2]: => 09:49:41.840 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: 1 endpoints: 09:49:41.842 CNTRLR « [Node 027] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 09:49:41.842 CNTRLR » [Node 027] querying additional non-multi-channel association groups... 09:49:41.842 CNTRLR » [Node 027] querying association group #3... 09:49:41.846 SERIAL » 0x010a00131b0385020325ce91 (12 bytes) 09:49:41.846 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 206 └─[AssociationCCGet] group id: 3 09:49:41.850 SERIAL « [ACK] (0x06) 09:49:41.858 SERIAL « 0x0104011301e8 (6 bytes) 09:49:41.858 SERIAL » [ACK] (0x06) 09:49:41.860 DRIVER « [RES] [SendData] was sent: true 09:49:41.871 SERIAL « 0x01070013ce00000227 (9 bytes) 09:49:41.872 SERIAL » [ACK] (0x06) 09:49:41.872 DRIVER « [REQ] [SendData] callback id: 206 transmit status: OK 09:49:41.883 SERIAL « 0x010c0004001b068503030100016f (14 bytes) 09:49:41.883 SERIAL » [ACK] (0x06) 09:49:41.884 CNTRLR [Node 027] [~] [Association] maxNodes[3]: 1 => 1 [internal] 09:49:41.884 CNTRLR [Node 027] [~] [Association] nodeIds[3]: 1 => 1 [internal] 09:49:41.884 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 09:49:41.886 CNTRLR « [Node 027] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 09:49:41.886 CNTRLR [Node 027] [~] [Association] hasLifeline: true => true [internal] 09:49:41.886 CNTRLR [Node 027] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 09:49:41.923 CNTRLR [Node 027] Interview stage completed: CommandClasses 09:49:41.923 CNTRLR [Node 027] Interview stage completed: OverwriteConfig 09:49:41.924 CNTRLR » [Node 027] requesting node neighbors... 09:49:41.927 SERIAL » 0x010700801b00000063 (9 bytes) 09:49:41.927 DRIVER » [Node 027] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:49:41.928 SERIAL « [ACK] (0x06) 09:49:41.932 SERIAL « 0x012001800530c4030000000000000000000000000000000000000000000000000 (34 bytes) 0ac 09:49:41.932 SERIAL » [ACK] (0x06) 09:49:41.933 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 13, 14, 19, 23, 24, 25, 26 09:49:41.935 CNTRLR « [Node 027] node neighbors received: 1, 3, 13, 14, 19, 23, 24, 25, 26 09:49:41.935 CNTRLR [Node 027] Interview stage completed: Neighbors 09:49:41.935 CNTRLR [Node 027] Interview completed 09:49:42.936 CNTRLR » [Node 027] Sending node back to sleep... 09:49:42.945 SERIAL » 0x010900131b02840825cf9a (11 bytes) 09:49:42.946 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 207 └─[WakeUpCCNoMoreInformation] 09:49:42.948 SERIAL « [ACK] (0x06) 09:49:42.954 SERIAL « 0x0104011301e8 (6 bytes) 09:49:42.954 SERIAL » [ACK] (0x06) 09:49:42.955 DRIVER « [RES] [SendData] was sent: true 09:49:42.972 SERIAL « 0x01070013cf00000226 (9 bytes) 09:49:42.972 SERIAL » [ACK] (0x06) 09:49:42.973 DRIVER « [REQ] [SendData] callback id: 207 transmit status: OK 09:49:42.976 CNTRLR [Node 027] The node is now asleep. 09:49:42.977 CNTRLR [Node 027] Node asleep 09:49:49.394 SERIAL « 0x01100004001d0a600d02003105012200b93d (18 bytes) 09:49:49.396 CNTRLR [Node 029] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:49:49.397 CNTRLR [Node 029] [~] [Multilevel Sensor] Air temperature: 19.4 => 18.5 [Endpoint 2] 09:49:49.398 SERIAL » [ACK] (0x06) 09:49:49.400 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.5 09:49:51.632 SERIAL « 0x01090004001b033003ff26 (11 bytes) 09:49:51.633 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:49:51.634 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:49:51.635 SERIAL » [ACK] (0x06) 09:49:51.637 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:49:51.686 SERIAL « 0x01090004001b032001ff34 (11 bytes) 09:49:51.687 SERIAL » [ACK] (0x06) 09:49:51.688 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:49:51.690 CNTRLR [Node 027] treating BasicCC Set as a report 09:49:51.691 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:50:17.057 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:50:17.058 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:50:17.059 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:50:17.059 SERIAL » [ACK] (0x06) 09:50:17.061 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:50:17.104 SERIAL « 0x010900040020032001ff0f (11 bytes) 09:50:17.104 SERIAL » [ACK] (0x06) 09:50:17.105 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:50:17.107 CNTRLR [Node 032] treating BasicCC Set as a report 09:50:17.107 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:50:17.114 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:50:17.115 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:50:17.116 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:50:17.116 SERIAL » [ACK] (0x06) 09:50:17.118 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:50:17.156 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:50:17.157 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:50:17.158 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:50:17.159 SERIAL » [ACK] (0x06) 09:50:17.160 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:50:17.233 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:50:17.234 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:50:17.235 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:50:17.235 SERIAL » [ACK] (0x06) 09:50:17.237 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:50:17.269 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:50:17.270 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:50:17.271 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:50:17.272 SERIAL » [ACK] (0x06) 09:50:17.273 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:50:17.312 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:50:17.313 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:50:17.314 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:50:17.315 SERIAL » [ACK] (0x06) 09:50:17.316 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:50:17.329 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:50:17.330 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:50:17.331 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:50:17.332 SERIAL » [ACK] (0x06) 09:50:17.334 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:50:17.389 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:50:17.390 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:50:17.391 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:50:17.392 SERIAL » [ACK] (0x06) 09:50:17.394 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:50:17.489 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:50:17.490 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:50:17.491 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:50:17.492 SERIAL » [ACK] (0x06) 09:50:17.493 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:50:17.737 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:50:17.738 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:50:17.739 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:50:17.740 SERIAL » [ACK] (0x06) 09:50:17.741 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:50:17.802 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:50:17.803 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:50:17.805 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:50:17.806 SERIAL » [ACK] (0x06) 09:50:17.807 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:50:17.820 SERIAL « 0x010900041020033003ff0d (11 bytes) 09:50:17.821 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:50:17.822 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:50:17.823 SERIAL » [ACK] (0x06) 09:50:17.825 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:50:51.091 SERIAL « 0x01090004001b03300300d9 (11 bytes) 09:50:51.092 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:50:51.093 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:50:51.094 SERIAL » [ACK] (0x06) 09:50:51.097 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:50:51.145 SERIAL « 0x01090004001b03200100cb (11 bytes) 09:50:51.159 SERIAL » [ACK] (0x06) 09:50:51.160 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:50:51.162 CNTRLR [Node 027] treating BasicCC Set as a report 09:50:51.162 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:50:53.402 SERIAL « 0x0110000400160a600d02003105012200b33c (18 bytes) 09:50:53.403 CNTRLR [Node 022] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:50:53.404 CNTRLR [Node 022] [~] [Multilevel Sensor] Air temperature: 17.5 => 17.9 [Endpoint 2] 09:50:53.404 SERIAL » [ACK] (0x06) 09:50:53.405 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 17.9 09:51:03.092 SERIAL « 0x01090004001b033003ff26 (11 bytes) 09:51:03.094 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:51:03.095 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:51:03.096 SERIAL » [ACK] (0x06) 09:51:03.098 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:51:03.141 SERIAL « 0x01090004001b032001ff34 (11 bytes) 09:51:03.141 SERIAL » [ACK] (0x06) 09:51:03.143 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:51:03.145 CNTRLR [Node 027] treating BasicCC Set as a report 09:51:03.145 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:51:20.273 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 09:51:20.274 SERIAL » [ACK] (0x06) 09:51:20.276 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 09:51:20.278 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 09:51:20.477 SERIAL « 0x01090004001e033003ff23 (11 bytes) 09:51:20.478 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:51:20.479 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:51:20.480 SERIAL » [ACK] (0x06) 09:51:20.482 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:51:20.506 SERIAL » 0x010e00131f07600d00012501ff25d0b8 (16 bytes) 09:51:20.519 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 208 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCSet] target value: true 09:51:20.522 SERIAL « [ACK] (0x06) 09:51:20.529 SERIAL « 0x0104011301e8 (6 bytes) 09:51:20.529 SERIAL » [ACK] (0x06) 09:51:20.530 DRIVER « [RES] [SendData] was sent: true 09:51:20.536 SERIAL « 0x01090004001e032001ff31 (11 bytes) 09:51:20.537 SERIAL » [ACK] (0x06) 09:51:20.538 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:51:20.540 CNTRLR [Node 030] treating BasicCC Set as a report 09:51:20.541 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:51:20.579 SERIAL « 0x01070013d00000063d (9 bytes) 09:51:20.579 SERIAL » [ACK] (0x06) 09:51:20.580 DRIVER « [REQ] [SendData] callback id: 208 transmit status: OK 09:51:20.589 SERIAL » 0x010d00131f06600d0001250225d147 (15 bytes) 09:51:20.589 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 209 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 09:51:20.591 SERIAL « [ACK] (0x06) 09:51:20.597 SERIAL « 0x0104011301e8 (6 bytes) 09:51:20.597 SERIAL » [ACK] (0x06) 09:51:20.598 DRIVER « [RES] [SendData] was sent: true 09:51:20.616 SERIAL « 0x01070013d100000339 (9 bytes) 09:51:20.617 SERIAL » [ACK] (0x06) 09:51:20.617 DRIVER « [REQ] [SendData] callback id: 209 transmit status: OK 09:51:20.628 SERIAL « 0x010d0004001f07600d01002503ff5b (15 bytes) 09:51:20.629 CNTRLR [Node 031] [~] [Binary Switch] currentValue: false => true [Endpoint 1] 09:51:20.629 SERIAL » [ACK] (0x06) 09:51:20.630 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: true 09:51:27.456 SERIAL « 0x010900040008033003ff35 (11 bytes) 09:51:27.457 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:51:27.458 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:51:27.459 SERIAL » [ACK] (0x06) 09:51:27.461 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:51:27.510 SERIAL « 0x010900040008032001ff27 (11 bytes) 09:51:27.511 SERIAL » [ACK] (0x06) 09:51:27.512 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:51:27.514 CNTRLR [Node 008] treating BasicCC Set as a report 09:51:27.514 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:51:39.394 SERIAL « 0x010c000400030631050422097f96 (14 bytes) 09:51:39.395 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:51:39.396 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 109.9 => 243.1 [Endpoint 0] 09:51:39.397 SERIAL » [ACK] (0x06) 09:51:39.400 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 243.1 09:51:40.394 SERIAL « 0x010c0004000306310504220403e7 (14 bytes) 09:51:40.394 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:51:40.395 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 243.1 => 102.7 [Endpoint 0] 09:51:40.396 SERIAL » [ACK] (0x06) 09:51:40.397 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 102.7 09:51:41.394 SERIAL « 0x010c00040003063105042204bd59 (14 bytes) 09:51:41.395 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:51:41.398 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 102.7 => 121.3 [Endpoint 0] 09:51:41.399 SERIAL » [ACK] (0x06) 09:51:41.401 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 121.3 09:51:42.394 SERIAL « 0x010c000400030631050422071dfa (14 bytes) 09:51:42.395 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:51:42.396 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 121.3 => 182.1 [Endpoint 0] 09:51:42.397 SERIAL » [ACK] (0x06) 09:51:42.399 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 182.1 09:51:44.394 SERIAL « 0x010c00040003063105042203f211 (14 bytes) 09:51:44.396 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:51:44.397 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 182.1 => 101 [Endpoint 0] 09:51:44.398 SERIAL » [ACK] (0x06) 09:51:44.399 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 101 09:51:45.745 SERIAL « 0x0112000400180c600d02003202213205460000f2 (20 bytes) 09:51:45.747 CNTRLR [Node 024] [~] [Meter] value[66049]: 109.3 => 135 [Endpoint 2] 09:51:45.748 CNTRLR [Node 024] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 2] 09:51:45.749 SERIAL » [ACK] (0x06) 09:51:45.751 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 135 time delta: 0 seconds 09:51:46.401 SERIAL « 0x010c00040003063105042205c227 (14 bytes) 09:51:46.403 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:51:46.404 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 101 => 147.4 [Endpoint 0] 09:51:46.405 SERIAL » [ACK] (0x06) 09:51:46.407 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 147.4 09:51:50.581 SERIAL « 0x01090004001e03300300dc (11 bytes) 09:51:50.583 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:51:50.584 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:51:50.585 SERIAL » [ACK] (0x06) 09:51:50.587 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:51:50.636 SERIAL « 0x01090004001e03200100ce (11 bytes) 09:51:50.637 SERIAL » [ACK] (0x06) 09:51:50.641 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:51:50.647 CNTRLR [Node 030] treating BasicCC Set as a report 09:51:50.647 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:51:50.889 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 09:51:50.889 SERIAL » [ACK] (0x06) 09:51:50.890 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  09:51:50.891 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 09:51:51.122 SERIAL « 0x01090004001e033003ff23 (11 bytes) 09:51:51.122 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:51:51.123 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:51:51.123 SERIAL » [ACK] (0x06) 09:51:51.124 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:51:51.176 SERIAL « 0x01090004001e032001ff31 (11 bytes) 09:51:51.176 SERIAL » [ACK] (0x06) 09:51:51.177 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:51:51.178 CNTRLR [Node 030] treating BasicCC Set as a report 09:51:51.178 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:51:51.332 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 09:51:51.333 SERIAL » [ACK] (0x06) 09:51:51.333 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 09:51:51.335 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 09:51:52.642 SERIAL « 0x010900040007033003ff3a (11 bytes) 09:51:52.643 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:51:52.644 CNTRLR [Node 007] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:51:52.646 SERIAL » [ACK] (0x06) 09:51:52.648 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:51:52.864 SERIAL « 0x0110000400070a7105000000ff0708000062 (18 bytes) 09:51:52.864 SERIAL » [ACK] (0x06) 09:51:52.865 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 09:51:52.866 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 09:51:55.745 SERIAL « 0x0112000400180c600d020032022132015b0000eb (20 bytes) 09:51:55.747 CNTRLR [Node 024] [~] [Meter] value[66049]: 135 => 34.7 [Endpoint 2] 09:51:55.748 CNTRLR [Node 024] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 2] 09:51:55.749 SERIAL » [ACK] (0x06) 09:51:55.751 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 34.7 time delta: 0 seconds 09:52:06.197 SERIAL « 0x01090004000803300300ca (11 bytes) 09:52:06.198 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:52:06.199 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:52:06.200 SERIAL » [ACK] (0x06) 09:52:06.201 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:52:06.252 SERIAL « 0x01090004000803200100d8 (11 bytes) 09:52:06.252 SERIAL » [ACK] (0x06) 09:52:06.253 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:52:06.255 CNTRLR [Node 008] treating BasicCC Set as a report 09:52:06.256 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:52:06.745 SERIAL « 0x0112000400180c600d02003202213201040000b4 (20 bytes) 09:52:06.746 CNTRLR [Node 024] [~] [Meter] value[66049]: 34.7 => 26 [Endpoint 2] 09:52:06.748 CNTRLR [Node 024] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 2] 09:52:06.748 SERIAL » [ACK] (0x06) 09:52:06.750 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 26 time delta: 0 seconds 09:52:07.028 SERIAL » 0x010e00131807600d000225010025d241 (16 bytes) 09:52:07.030 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 210 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[BinarySwitchCCSet] target value: false 09:52:07.032 SERIAL « [ACK] (0x06) 09:52:07.038 SERIAL « 0x0104011301e8 (6 bytes) 09:52:07.039 SERIAL » [ACK] (0x06) 09:52:07.040 DRIVER « [RES] [SendData] was sent: true 09:52:07.060 SERIAL « 0x01070013d20000033a (9 bytes) 09:52:07.061 SERIAL » [ACK] (0x06) 09:52:07.062 DRIVER « [REQ] [SendData] callback id: 210 transmit status: OK 09:52:07.078 SERIAL » 0x010d00131806600d0002250225d341 (15 bytes) 09:52:07.078 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 211 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[BinarySwitchCCGet] 09:52:07.080 SERIAL « [ACK] (0x06) 09:52:07.087 SERIAL « 0x0104011301e8 (6 bytes) 09:52:07.087 SERIAL » [ACK] (0x06) 09:52:07.088 DRIVER « [RES] [SendData] was sent: true 09:52:07.108 SERIAL « 0x01070013d30000033b (9 bytes) 09:52:07.109 SERIAL » [ACK] (0x06) 09:52:07.109 DRIVER « [REQ] [SendData] callback id: 211 transmit status: OK 09:52:07.123 SERIAL « 0x010d0004001807600d02002503ff5f (15 bytes) 09:52:07.123 CNTRLR [Node 024] [~] [Binary Switch] currentValue: true => true [Endpoint 2] 09:52:07.124 SERIAL » [ACK] (0x06) 09:52:07.125 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BinarySwitchCCReport] current value: true 09:52:07.147 SERIAL « 0x010d0004001807600d0200250300a0 (15 bytes) 09:52:07.148 CNTRLR [Node 024] [~] [Binary Switch] currentValue: true => false [Endpoint 2] 09:52:07.148 SERIAL » [ACK] (0x06) 09:52:07.150 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BinarySwitchCCReport] current value: false 09:52:07.719 SERIAL « 0x0112000400180c600d02003202213200000000b1 (20 bytes) 09:52:07.720 CNTRLR [Node 024] [~] [Meter] value[66049]: 26 => 0 [Endpoint 2] 09:52:07.722 CNTRLR [Node 024] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 2] 09:52:07.723 SERIAL » [ACK] (0x06) 09:52:07.725 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 09:52:11.397 SERIAL « 0x010c00040003063105042204a246 (14 bytes) 09:52:11.398 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:52:11.400 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 147.4 => 118.6 [Endpoint 0] 09:52:11.401 SERIAL » [ACK] (0x06) 09:52:11.403 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 118.6 09:52:18.398 SERIAL « 0x010c000400030631050422099a73 (14 bytes) 09:52:18.399 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:52:18.404 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 118.6 => 245.8 [Endpoint 0] 09:52:18.405 SERIAL » [ACK] (0x06) 09:52:18.407 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 245.8 09:52:19.242 SERIAL « 0x01090004000703300300c5 (11 bytes) 09:52:19.243 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:52:19.244 CNTRLR [Node 007] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:52:19.245 SERIAL » [ACK] (0x06) 09:52:19.246 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:52:19.398 SERIAL « 0x010c0004000306310504220517f2 (14 bytes) 09:52:19.399 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:52:19.400 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 245.8 => 130.3 [Endpoint 0] 09:52:19.401 SERIAL » [ACK] (0x06) 09:52:19.403 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 130.3 09:52:19.464 SERIAL « 0x0110000400070a7105000000ff070000006a (18 bytes) 09:52:19.465 SERIAL » [ACK] (0x06) 09:52:19.466 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) 09:52:19.500 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 09:52:20.398 SERIAL « 0x010c00040003063105042208947c (14 bytes) 09:52:20.399 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:52:20.400 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 130.3 => 219.6 [Endpoint 0] 09:52:20.401 SERIAL » [ACK] (0x06) 09:52:20.402 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 219.6 09:52:21.398 SERIAL « 0x010c00040003063105042204f014 (14 bytes) 09:52:21.399 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:52:21.400 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 219.6 => 126.4 [Endpoint 0] 09:52:21.401 SERIAL » [ACK] (0x06) 09:52:21.403 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 126.4 09:52:21.467 SERIAL « 0x01090004001e03300300dc (11 bytes) 09:52:21.472 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:52:21.474 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:52:21.475 SERIAL » [ACK] (0x06) 09:52:21.476 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:52:21.486 SERIAL « 0x01090004001e03200100ce (11 bytes) 09:52:21.486 SERIAL » [ACK] (0x06) 09:52:21.489 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:52:21.491 CNTRLR [Node 030] treating BasicCC Set as a report 09:52:21.492 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:52:22.362 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 09:52:22.363 SERIAL » [ACK] (0x06) 09:52:22.365 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  09:52:22.368 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 09:52:30.509 SERIAL « 0x01090004001b03300300d9 (11 bytes) 09:52:30.509 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:52:30.510 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:52:30.510 SERIAL » [ACK] (0x06) 09:52:30.511 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:52:30.563 SERIAL « 0x01090004001b03200100cb (11 bytes) 09:52:30.563 SERIAL » [ACK] (0x06) 09:52:30.564 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:52:30.565 CNTRLR [Node 027] treating BasicCC Set as a report 09:52:30.565 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:52:42.400 SERIAL « 0x010c0004000306310504220937de (14 bytes) 09:52:42.401 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:52:42.402 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 126.4 => 235.9 [Endpoint 0] 09:52:42.403 SERIAL » [ACK] (0x06) 09:52:42.405 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 235.9 09:52:43.400 SERIAL « 0x010c000400030631050422035ebd (14 bytes) 09:52:43.401 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:52:43.401 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 235.9 => 86.2 [Endpoint 0] 09:52:43.402 SERIAL » [ACK] (0x06) 09:52:43.403 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 86.2 09:52:44.400 SERIAL « 0x010c00040003063105042204dc38 (14 bytes) 09:52:44.401 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:52:44.403 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 86.2 => 124.4 [Endpoint 0] 09:52:44.404 SERIAL » [ACK] (0x06) 09:52:44.405 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 124.4 09:52:45.401 SERIAL « 0x010c00040003063105042207f91e (14 bytes) 09:52:45.402 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:52:45.403 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 124.4 => 204.1 [Endpoint 0] 09:52:45.404 SERIAL » [ACK] (0x06) 09:52:45.405 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 204.1 09:52:46.401 SERIAL « 0x010c000400030631050422048662 (14 bytes) 09:52:46.402 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:52:46.403 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 204.1 => 115.8 [Endpoint 0] 09:52:46.404 SERIAL » [ACK] (0x06) 09:52:46.405 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 115.8 09:52:51.401 SERIAL « 0x010c0004000306310504220936df (14 bytes) 09:52:51.402 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:52:51.404 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 115.8 => 235.8 [Endpoint 0] 09:52:51.404 SERIAL » [ACK] (0x06) 09:52:51.406 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 235.8 09:52:57.142 SERIAL « 0x010900040007033003ff3a (11 bytes) 09:52:57.144 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:52:57.145 CNTRLR [Node 007] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:52:57.146 SERIAL » [ACK] (0x06) 09:52:57.147 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:52:57.364 SERIAL « 0x0110000400070a7105000000ff0708000062 (18 bytes) 09:52:57.365 SERIAL » [ACK] (0x06) 09:52:57.366 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 09:52:57.369 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 09:53:13.403 SERIAL « 0x010c000400030631050422041df9 (14 bytes) 09:53:13.404 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:53:13.404 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 235.8 => 105.3 [Endpoint 0] 09:53:13.405 SERIAL » [ACK] (0x06) 09:53:13.405 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 105.3 09:53:14.404 SERIAL « 0x010c0004000306310504220554b1 (14 bytes) 09:53:14.405 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:53:14.406 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 105.3 => 136.4 [Endpoint 0] 09:53:14.407 SERIAL » [ACK] (0x06) 09:53:14.408 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 136.4 09:53:15.404 SERIAL « 0x010c000400030631050422077592 (14 bytes) 09:53:15.405 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:53:15.406 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 136.4 => 190.9 [Endpoint 0] 09:53:15.407 SERIAL » [ACK] (0x06) 09:53:15.408 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 190.9 09:53:16.404 SERIAL « 0x010c0004000306310504220420c4 (14 bytes) 09:53:16.405 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:53:16.406 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 190.9 => 105.6 [Endpoint 0] 09:53:16.407 SERIAL » [ACK] (0x06) 09:53:16.408 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 105.6 09:53:18.404 SERIAL « 0x010c0004000306310504220527c2 (14 bytes) 09:53:18.405 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:53:18.406 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 105.6 => 131.9 [Endpoint 0] 09:53:18.407 SERIAL » [ACK] (0x06) 09:53:18.408 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 131.9 09:53:19.404 SERIAL « 0x010c00040003063105042209a34a (14 bytes) 09:53:19.405 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:53:19.406 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 131.9 => 246.7 [Endpoint 0] 09:53:19.407 SERIAL » [ACK] (0x06) 09:53:19.409 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 246.7 09:53:21.490 SERIAL » 0x010e00131f07600d000125010025d443 (16 bytes) 09:53:21.491 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 212 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCSet] target value: false 09:53:21.493 SERIAL « [ACK] (0x06) 09:53:21.499 SERIAL « 0x0104011301e8 (6 bytes) 09:53:21.500 SERIAL » [ACK] (0x06) 09:53:21.500 DRIVER « [RES] [SendData] was sent: true 09:53:21.518 SERIAL « 0x01070013d40000033c (9 bytes) 09:53:21.518 SERIAL » [ACK] (0x06) 09:53:21.518 DRIVER « [REQ] [SendData] callback id: 212 transmit status: OK 09:53:21.526 SERIAL » 0x010d00131f06600d0001250225d543 (15 bytes) 09:53:21.526 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 213 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 09:53:21.528 SERIAL « [ACK] (0x06) 09:53:21.535 SERIAL « 0x0104011301e8 (6 bytes) 09:53:21.535 SERIAL » [ACK] (0x06) 09:53:21.535 DRIVER « [RES] [SendData] was sent: true 09:53:21.552 SERIAL « 0x01070013d50000023c (9 bytes) 09:53:21.553 SERIAL » [ACK] (0x06) 09:53:21.553 DRIVER « [REQ] [SendData] callback id: 213 transmit status: OK 09:53:21.564 SERIAL « 0x010d0004001f07600d0100250300a4 (15 bytes) 09:53:21.565 CNTRLR [Node 031] [~] [Binary Switch] currentValue: true => false [Endpoint 1] 09:53:21.565 SERIAL » [ACK] (0x06) 09:53:21.566 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: false 09:53:24.341 SERIAL « 0x01090004000b0380034b32 (11 bytes) 09:53:24.343 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 09:53:24.344 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 09:53:24.344 SERIAL » [ACK] (0x06) 09:53:24.346 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 09:53:24.400 SERIAL « 0x010c0004000b0643030142019068 (14 bytes) 09:53:24.404 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpoint[1]: 4 => 4 [Endpoint 0] 09:53:24.405 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 09:53:24.406 SERIAL » [ACK] (0x06) 09:53:24.408 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 4 °C 09:53:24.457 SERIAL « 0x010a0004000b044608007fcf (12 bytes) 09:53:24.459 CNTRLR [Node 011] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 09:53:24.461 CNTRLR [Node 011] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 09:53:24.461 SERIAL » [ACK] (0x06) 09:53:24.464 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ClimateControlScheduleCCOverrideReport] override type: None override state: Unused 09:53:24.512 SERIAL « 0x01080004000b02840779 (10 bytes) 09:53:24.513 SERIAL » [ACK] (0x06) 09:53:24.513 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:53:24.515 CNTRLR « [Node 011] received wakeup notification 09:53:24.515 CNTRLR [Node 011] The node is now awake. 09:53:24.516 CNTRLR [Node 011] expects some queries after wake up, so it shall receive 09:53:24.516 CNTRLR [Node 011] compat query "Battery"::get() 09:53:24.523 SERIAL » 0x010900130b02800225d69d (11 bytes) 09:53:24.524 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 214 └─[BatteryCCGet] 09:53:24.526 SERIAL « [ACK] (0x06) 09:53:24.535 SERIAL « 0x0104011301e8 (6 bytes) 09:53:24.536 SERIAL » [ACK] (0x06) 09:53:24.536 DRIVER « [RES] [SendData] was sent: true 09:53:24.556 SERIAL « 0x01070013d60000033e (9 bytes) 09:53:24.556 SERIAL » [ACK] (0x06) 09:53:24.557 DRIVER « [REQ] [SendData] callback id: 214 transmit status: OK 09:53:24.569 SERIAL « 0x01090004000b0380034b32 (11 bytes) 09:53:24.569 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 09:53:24.570 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 09:53:24.571 SERIAL » [ACK] (0x06) 09:53:24.572 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 09:53:24.577 SERIAL » 0x010a00130b0343020125d75c (12 bytes) 09:53:24.577 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 215 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:53:24.578 CNTRLR « [Node 011] received response for battery information: level: 75 09:53:24.582 CNTRLR [Node 011] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:53:24.623 SERIAL « [ACK] (0x06) 09:53:24.624 SERIAL « 0x0104011301e8 (6 bytes) 09:53:24.625 SERIAL » [ACK] (0x06) 09:53:24.628 DRIVER « [RES] [SendData] was sent: true 09:53:24.632 SERIAL « 0x01070013d70000023e (9 bytes) 09:53:24.632 SERIAL » [ACK] (0x06) 09:53:24.633 CNTRLR [Node 011] WakeUpCC: doing a partial interview... 09:53:24.633 CNTRLR » [Node 011] retrieving wakeup interval from the device... 09:53:24.635 DRIVER « [REQ] [SendData] callback id: 215 transmit status: OK 09:53:24.639 SERIAL « 0x010c0004000b0643030142019068 (14 bytes) 09:53:24.640 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpoint[1]: 4 => 4 [Endpoint 0] 09:53:24.641 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 09:53:24.641 SERIAL » [ACK] (0x06) 09:53:24.642 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 4 °C 09:53:24.645 SERIAL » 0x010a00130b0343020125d853 (12 bytes) 09:53:24.646 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 216 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:53:24.647 CNTRLR [Node 011] API call successful 09:53:24.648 SERIAL « [ACK] (0x06) 09:53:24.654 SERIAL « 0x0104011301e8 (6 bytes) 09:53:24.654 SERIAL » [ACK] (0x06) 09:53:24.655 DRIVER « [RES] [SendData] was sent: true 09:53:24.671 SERIAL « 0x01070013d800000231 (9 bytes) 09:53:24.672 SERIAL » [ACK] (0x06) 09:53:24.673 DRIVER « [REQ] [SendData] callback id: 216 transmit status: OK 09:53:24.682 SERIAL « 0x010c0004000b0643030142019068 (14 bytes) 09:53:24.683 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpoint[1]: 4 => 4 [Endpoint 0] 09:53:24.683 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 09:53:24.684 SERIAL » [ACK] (0x06) 09:53:24.685 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 4 °C 09:53:24.689 SERIAL » 0x010900130b02800225d992 (11 bytes) 09:53:24.689 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 217 └─[BatteryCCGet] 09:53:24.690 CNTRLR [Node 011] API call successful 09:53:24.693 SERIAL « [ACK] (0x06) 09:53:24.697 SERIAL « 0x0104011301e8 (6 bytes) 09:53:24.697 SERIAL » [ACK] (0x06) 09:53:24.698 DRIVER « [RES] [SendData] was sent: true 09:53:24.714 SERIAL « 0x01070013d900000230 (9 bytes) 09:53:24.717 SERIAL » [ACK] (0x06) 09:53:24.717 DRIVER « [REQ] [SendData] callback id: 217 transmit status: OK 09:53:24.725 SERIAL « 0x01090004000b0380034b32 (11 bytes) 09:53:24.725 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 09:53:24.726 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 09:53:24.726 SERIAL » [ACK] (0x06) 09:53:24.727 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 09:53:24.731 SERIAL » 0x010900130b02840525da92 (11 bytes) 09:53:24.731 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 218 └─[WakeUpCCIntervalGet] 09:53:24.732 CNTRLR [Node 011] API call successful 09:53:24.733 CNTRLR [Node 011] compat query "Thermostat Setpoint"::get(1) 09:53:24.737 SERIAL « [ACK] (0x06) 09:53:24.740 SERIAL « 0x0104011301e8 (6 bytes) 09:53:24.741 SERIAL » [ACK] (0x06) 09:53:24.742 DRIVER « [RES] [SendData] was sent: true 09:53:24.757 SERIAL « 0x01070013da00000332 (9 bytes) 09:53:24.757 SERIAL » [ACK] (0x06) 09:53:24.757 DRIVER « [REQ] [SendData] callback id: 218 transmit status: OK 09:53:24.768 SERIAL « 0x010c0004000b06840600038401fe (14 bytes) 09:53:24.769 CNTRLR [Node 011] [~] [Wake Up] wakeUpInterval: 900 => 900 [Endpoint 0] 09:53:24.769 CNTRLR [Node 011] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 09:53:24.770 SERIAL » [ACK] (0x06) 09:53:24.771 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 900 seconds controller node id: 1 09:53:24.774 SERIAL » 0x010a00130b0343020125db50 (12 bytes) 09:53:24.774 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 219 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:53:24.778 CNTRLR « [Node 011] received wakeup configuration: wakeup interval: 900 seconds controller node: 1 09:53:24.778 CNTRLR [Node 011] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:53:24.779 CNTRLR [Node 011] ThermostatSetpointCC: doing a partial interview... 09:53:24.779 CNTRLR » [Node 011] querying current value of setpoint Heating... 09:53:24.784 SERIAL « [ACK] (0x06) 09:53:24.786 SERIAL « 0x0104011301e8 (6 bytes) 09:53:24.786 SERIAL » [ACK] (0x06) 09:53:24.787 DRIVER « [RES] [SendData] was sent: true 09:53:24.803 SERIAL « 0x01070013db00000232 (9 bytes) 09:53:24.803 SERIAL » [ACK] (0x06) 09:53:24.803 DRIVER « [REQ] [SendData] callback id: 219 transmit status: OK 09:53:24.814 SERIAL « 0x010c0004000b0643030142019068 (14 bytes) 09:53:24.814 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpoint[1]: 4 => 4 [Endpoint 0] 09:53:24.815 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 09:53:24.815 SERIAL » [ACK] (0x06) 09:53:24.816 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 4 °C 09:53:24.819 SERIAL » 0x010a00130b0343020125dc57 (12 bytes) 09:53:24.820 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 220 └─[ThermostatSetpointCCGet] setpoint type: Heating 09:53:24.820 CNTRLR [Node 011] API call successful 09:53:24.821 SERIAL « [ACK] (0x06) 09:53:24.828 SERIAL « 0x0104011301e8 (6 bytes) 09:53:24.828 SERIAL » [ACK] (0x06) 09:53:24.829 DRIVER « [RES] [SendData] was sent: true 09:53:24.845 SERIAL « 0x01070013dc00000334 (9 bytes) 09:53:24.845 SERIAL » [ACK] (0x06) 09:53:24.846 DRIVER « [REQ] [SendData] callback id: 220 transmit status: OK 09:53:24.856 SERIAL « 0x010c0004000b0643030142019068 (14 bytes) 09:53:24.857 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpoint[1]: 4 => 4 [Endpoint 0] 09:53:24.860 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 09:53:24.860 SERIAL » [ACK] (0x06) 09:53:24.861 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 4 °C 09:53:24.862 CNTRLR « [Node 011] received current value of setpoint Heating: 4 °C 09:53:24.863 CNTRLR [Node 011] [~] [Thermostat Setpoint] interviewComplete [Endpoint 0] [internal] : true => true 09:53:24.900 CNTRLR [Node 011] ProtectionCC: doing a partial interview... 09:53:24.901 CNTRLR » [Node 011] querying protection status... 09:53:24.907 SERIAL » 0x010900130b02750225dd63 (11 bytes) 09:53:24.907 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 221 └─[ProtectionCCGet] 09:53:24.909 SERIAL « [ACK] (0x06) 09:53:24.915 SERIAL « 0x0104011301e8 (6 bytes) 09:53:24.915 SERIAL » [ACK] (0x06) 09:53:24.916 DRIVER « [RES] [SendData] was sent: true 09:53:24.932 SERIAL « 0x01070013dd00000234 (9 bytes) 09:53:24.932 SERIAL » [ACK] (0x06) 09:53:24.933 DRIVER « [REQ] [SendData] callback id: 221 transmit status: OK 09:53:24.942 SERIAL « 0x010a0004000b047503000088 (12 bytes) 09:53:24.943 CNTRLR [Node 011] [~] [Protection] local: 0 => 0 [Endpoint 0] 09:53:24.944 SERIAL » [ACK] (0x06) 09:53:24.945 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 09:53:24.946 CNTRLR « [Node 011] received protection status: local: Unprotected rf Unprotected 09:53:24.947 CNTRLR [Node 011] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 09:53:24.947 CNTRLR [Node 011] ClockCC: doing a partial interview... 09:53:24.948 CNTRLR » [Node 011] requesting current clock setting... 09:53:24.955 SERIAL » 0x010900130b02810525de93 (11 bytes) 09:53:24.956 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 222 └─[ClockCCGet] 09:53:24.959 SERIAL « [ACK] (0x06) 09:53:24.963 SERIAL « 0x0104011301e8 (6 bytes) 09:53:24.964 SERIAL » [ACK] (0x06) 09:53:24.964 DRIVER « [RES] [SendData] was sent: true 09:53:24.981 SERIAL « 0x01070013de00000237 (9 bytes) 09:53:24.981 SERIAL » [ACK] (0x06) 09:53:24.981 DRIVER « [REQ] [SendData] callback id: 222 transmit status: OK 09:53:24.991 SERIAL « 0x010a0004000b04810661332b (12 bytes) 09:53:24.992 SERIAL » [ACK] (0x06) 09:53:24.993 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ClockCCReport] clock setting: Wednesday, 01:51 09:53:24.997 CNTRLR « [Node 011] received current clock setting: Wednesday, 01:51 09:53:24.997 CNTRLR [Node 011] [~] [Clock] interviewComplete: true => true [Endpoint 0] [internal] 09:53:24.997 CNTRLR [Node 011] Interview stage completed: CommandClasses 09:53:24.997 CNTRLR [Node 011] Interview stage completed: OverwriteConfig 09:53:24.997 CNTRLR » [Node 011] requesting node neighbors... 09:53:25.001 SERIAL » 0x010700800b00000073 (9 bytes) 09:53:25.001 DRIVER » [Node 011] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:53:25.002 SERIAL « [ACK] (0x06) 09:53:25.006 SERIAL « 0x01200180450300000000000000000000000000000000000000000000000000000 (34 bytes) 018 09:53:25.006 SERIAL » [ACK] (0x06) 09:53:25.006 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 7, 9, 10 09:53:25.009 CNTRLR « [Node 011] node neighbors received: 1, 3, 7, 9, 10 09:53:25.009 CNTRLR [Node 011] Interview stage completed: Neighbors 09:53:25.009 CNTRLR [Node 011] Interview completed 09:53:26.009 CNTRLR » [Node 011] Sending node back to sleep... 09:53:26.018 SERIAL » 0x010900130b02840825df9a (11 bytes) 09:53:26.019 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 223 └─[WakeUpCCNoMoreInformation] 09:53:26.021 SERIAL « [ACK] (0x06) 09:53:26.027 SERIAL « 0x0104011301e8 (6 bytes) 09:53:26.028 SERIAL » [ACK] (0x06) 09:53:26.028 DRIVER « [RES] [SendData] was sent: true 09:53:26.044 SERIAL « 0x01070013df00000236 (9 bytes) 09:53:26.044 SERIAL » [ACK] (0x06) 09:53:26.045 DRIVER « [REQ] [SendData] callback id: 223 transmit status: OK 09:53:26.050 CNTRLR [Node 011] The node is now asleep. 09:53:26.052 CNTRLR [Node 011] Node asleep 09:53:27.827 SERIAL « 0x01090004001e033003ff23 (11 bytes) 09:53:27.829 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:53:27.830 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:53:27.831 SERIAL » [ACK] (0x06) 09:53:27.833 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:53:27.864 SERIAL » 0x010e00131f07600d00012501ff25e088 (16 bytes) 09:53:27.865 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 224 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCSet] target value: true 09:53:27.867 SERIAL « [ACK] (0x06) 09:53:27.873 SERIAL « 0x0104011301e8 (6 bytes) 09:53:27.874 SERIAL » [ACK] (0x06) 09:53:27.875 DRIVER « [RES] [SendData] was sent: true 09:53:27.882 SERIAL « 0x01090004001e032001ff31 (11 bytes) 09:53:27.883 SERIAL » [ACK] (0x06) 09:53:27.884 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:53:27.892 CNTRLR [Node 030] treating BasicCC Set as a report 09:53:27.893 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:53:27.926 SERIAL « 0x01070013e00000060d (9 bytes) 09:53:27.927 SERIAL » [ACK] (0x06) 09:53:27.927 DRIVER « [REQ] [SendData] callback id: 224 transmit status: OK 09:53:27.937 SERIAL » 0x010d00131f06600d0001250225e177 (15 bytes) 09:53:27.938 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 225 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 09:53:27.940 SERIAL « [ACK] (0x06) 09:53:27.946 SERIAL « 0x0104011301e8 (6 bytes) 09:53:27.946 SERIAL » [ACK] (0x06) 09:53:27.947 DRIVER « [RES] [SendData] was sent: true 09:53:27.964 SERIAL « 0x01070013e100000208 (9 bytes) 09:53:27.964 SERIAL » [ACK] (0x06) 09:53:27.965 DRIVER « [REQ] [SendData] callback id: 225 transmit status: OK 09:53:27.975 SERIAL « 0x010d0004001f07600d01002503ff5b (15 bytes) 09:53:27.976 CNTRLR [Node 031] [~] [Binary Switch] currentValue: false => true [Endpoint 1] 09:53:27.977 SERIAL » [ACK] (0x06) 09:53:27.978 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: true 09:53:28.098 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 09:53:28.098 SERIAL » [ACK] (0x06) 09:53:28.099 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 09:53:28.100 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 09:53:29.281 SERIAL « 0x01080004001e0284076c (10 bytes) 09:53:29.282 SERIAL » [ACK] (0x06) 09:53:29.283 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:53:29.285 CNTRLR « [Node 030] received wakeup notification 09:53:29.286 CNTRLR [Node 030] The node is now awake. 09:53:29.293 SERIAL » 0x010900131e02800225e2bc (11 bytes) 09:53:29.293 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 226 └─[BatteryCCGet] 09:53:29.296 SERIAL « [ACK] (0x06) 09:53:29.302 SERIAL « 0x0104011301e8 (6 bytes) 09:53:29.303 SERIAL » [ACK] (0x06) 09:53:29.304 DRIVER « [RES] [SendData] was sent: true 09:53:29.343 SERIAL « 0x01070013e20000020b (9 bytes) 09:53:29.344 SERIAL » [ACK] (0x06) 09:53:29.345 DRIVER « [REQ] [SendData] callback id: 226 transmit status: OK 09:53:29.351 SERIAL « 0x01090004001e038003600c (11 bytes) 09:53:29.364 CNTRLR [Node 030] [~] [Battery] level: 96 => 96 [Endpoint 0] 09:53:29.366 CNTRLR [Node 030] [~] [Battery] isLow: false => false [Endpoint 0] 09:53:29.366 SERIAL » [ACK] (0x06) 09:53:29.369 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 96 is low: false 09:53:29.383 CNTRLR « [Node 030] received response for battery information: level: 96 09:53:29.384 CNTRLR [Node 030] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:53:29.449 CNTRLR [Node 030] WakeUpCC: doing a partial interview... 09:53:29.449 CNTRLR » [Node 030] retrieving wakeup interval from the device... 09:53:29.456 SERIAL » 0x010900131e02840525e3be (11 bytes) 09:53:29.457 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 227 └─[WakeUpCCIntervalGet] 09:53:29.458 SERIAL « [ACK] (0x06) 09:53:29.464 SERIAL « 0x0104011301e8 (6 bytes) 09:53:29.465 SERIAL » [ACK] (0x06) 09:53:29.465 DRIVER « [RES] [SendData] was sent: true 09:53:29.482 SERIAL « 0x01070013e30000020a (9 bytes) 09:53:29.483 SERIAL » [ACK] (0x06) 09:53:29.483 DRIVER « [REQ] [SendData] callback id: 227 transmit status: OK 09:53:29.493 SERIAL « 0x010c0004001e06840600038401eb (14 bytes) 09:53:29.494 CNTRLR [Node 030] [~] [Wake Up] wakeUpInterval: 900 => 900 [Endpoint 0] 09:53:29.495 CNTRLR [Node 030] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 09:53:29.495 SERIAL » [ACK] (0x06) 09:53:29.496 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 900 seconds controller node id: 1 09:53:29.497 CNTRLR « [Node 030] received wakeup configuration: wakeup interval: 900 seconds controller node: 1 09:53:29.503 CNTRLR [Node 030] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:53:29.504 CNTRLR [Node 030] AssociationCC: doing a partial interview... 09:53:29.504 CNTRLR [Node 030] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 09:53:29.504 CNTRLR [Node 030] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:53:29.505 CNTRLR [Node 030] BasicCC: doing a partial interview... 09:53:29.505 CNTRLR » [Node 030] querying Basic CC state... 09:53:29.509 SERIAL » 0x010900131e02200225e41a (11 bytes) 09:53:29.510 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 228 └─[BasicCCGet] 09:53:29.512 SERIAL « [ACK] (0x06) 09:53:29.518 SERIAL « 0x0104011301e8 (6 bytes) 09:53:29.518 SERIAL » [ACK] (0x06) 09:53:29.518 DRIVER « [RES] [SendData] was sent: true 09:53:29.535 SERIAL « 0x01070013e40000030c (9 bytes) 09:53:29.535 SERIAL » [ACK] (0x06) 09:53:29.536 DRIVER « [REQ] [SendData] callback id: 228 transmit status: OK 09:53:29.545 SERIAL « 0x01090004001e032003ff33 (11 bytes) 09:53:29.545 SERIAL » [ACK] (0x06) 09:53:29.546 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCReport] current value: 99 09:53:29.547 CNTRLR « [Node 030] received Basic CC state: current value: 99 09:53:29.547 CNTRLR [Node 030] [~] [Basic] interviewComplete: true => true [Endpoint 0] [internal] 09:53:29.548 CNTRLR [Node 030] BinarySensorCC: doing a partial interview... 09:53:29.548 CNTRLR » [Node 030] querying current value... 09:53:29.552 SERIAL » 0x010900131e02300225e50b (11 bytes) 09:53:29.552 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 229 └─[BinarySensorCCGet] type: Any 09:53:29.555 SERIAL « [ACK] (0x06) 09:53:29.560 SERIAL « 0x0104011301e8 (6 bytes) 09:53:29.561 SERIAL » [ACK] (0x06) 09:53:29.561 DRIVER « [RES] [SendData] was sent: true 09:53:29.577 SERIAL « 0x01070013e50000020c (9 bytes) 09:53:29.577 SERIAL » [ACK] (0x06) 09:53:29.578 DRIVER « [REQ] [SendData] callback id: 229 transmit status: OK 09:53:29.586 SERIAL « 0x01090004001e033003ff23 (11 bytes) 09:53:29.587 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:53:29.587 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:53:29.588 SERIAL » [ACK] (0x06) 09:53:29.589 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:53:29.590 CNTRLR « [Node 030] received current value: true 09:53:29.590 CNTRLR [Node 030] [~] [Binary Sensor] interviewComplete: true [Endpoint 0] [internal] => true 09:53:29.591 CNTRLR [Node 030] MultilevelSensorCC: doing a partial interview... 09:53:29.591 CNTRLR » [Node 030] querying Air temperature sensor reading... 09:53:29.595 SERIAL » 0x010b00131e043104010025e60a (13 bytes) 09:53:29.595 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 230 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:53:29.597 SERIAL « [ACK] (0x06) 09:53:29.603 SERIAL « 0x0104011301e8 (6 bytes) 09:53:29.604 SERIAL » [ACK] (0x06) 09:53:29.604 DRIVER « [RES] [SendData] was sent: true 09:53:29.621 SERIAL « 0x01070013e60000020f (9 bytes) 09:53:29.621 SERIAL » [ACK] (0x06) 09:53:29.621 DRIVER « [REQ] [SendData] callback id: 230 transmit status: OK 09:53:29.632 SERIAL « 0x010c0004001e063105012200d32b (14 bytes) 09:53:29.633 CNTRLR [Node 030] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 09:53:29.634 CNTRLR [Node 030] [~] [Multilevel Sensor] Air temperature: 21 => 21.1 [Endpoint 0] 09:53:29.634 SERIAL » [ACK] (0x06) 09:53:29.635 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 21.1 09:53:29.638 CNTRLR « [Node 030] received current Air temperature sensor reading: 21.1 °C 09:53:29.639 CNTRLR » [Node 030] querying Illuminance sensor reading... 09:53:29.642 SERIAL » 0x010b00131e043104030825e701 (13 bytes) 09:53:29.643 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 231 └─[MultilevelSensorCCGet] sensor type: Illuminance scale: Lux 09:53:29.651 SERIAL « [ACK] (0x06) 09:53:29.653 SERIAL « 0x0104011301e8 (6 bytes) 09:53:29.653 SERIAL » [ACK] (0x06) 09:53:29.654 DRIVER « [RES] [SendData] was sent: true 09:53:29.686 SERIAL « 0x01070013e70000020e (9 bytes) 09:53:29.687 SERIAL » [ACK] (0x06) 09:53:29.687 DRIVER « [REQ] [SendData] callback id: 231 transmit status: OK 09:53:29.690 SERIAL « 0x010c0004001e063105030a0001d3 (14 bytes) 09:53:29.690 CNTRLR [Node 030] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 09:53:29.691 CNTRLR [Node 030] [~] [Multilevel Sensor] Illuminance: 0 => 1 [Endpoint 0] 09:53:29.691 SERIAL » [ACK] (0x06) 09:53:29.692 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 1 09:53:29.695 CNTRLR « [Node 030] received current Illuminance sensor reading: 1 Lux 09:53:29.695 CNTRLR [Node 030] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 09:53:29.695 CNTRLR [Node 030] ConfigurationCC: Loading configuration parameters from device confi g 09:53:29.702 CNTRLR [Node 030] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:53:29.703 CNTRLR [Node 030] [Configuration] 1: metadata updated 09:53:29.704 CNTRLR [Node 030] [Configuration] 2: metadata updated 09:53:29.705 CNTRLR [Node 030] [Configuration] 3: metadata updated 09:53:29.706 CNTRLR [Node 030] [Configuration] 4: metadata updated 09:53:29.707 CNTRLR [Node 030] [Configuration] 6: metadata updated 09:53:29.708 CNTRLR [Node 030] [Configuration] 8: metadata updated 09:53:29.709 CNTRLR [Node 030] [Configuration] 9: metadata updated 09:53:29.710 CNTRLR [Node 030] [Configuration] 12: metadata updated 09:53:29.711 CNTRLR [Node 030] [Configuration] 14: metadata updated 09:53:29.712 CNTRLR [Node 030] [Configuration] 16: metadata updated 09:53:29.713 CNTRLR [Node 030] [Configuration] 20: metadata updated 09:53:29.714 CNTRLR [Node 030] [Configuration] 22: metadata updated 09:53:29.715 CNTRLR [Node 030] [Configuration] 24: metadata updated 09:53:29.716 CNTRLR [Node 030] [Configuration] 26: metadata updated 09:53:29.717 CNTRLR [Node 030] [Configuration] 40: metadata updated 09:53:29.719 CNTRLR [Node 030] [Configuration] 42: metadata updated 09:53:29.720 CNTRLR [Node 030] [Configuration] 60: metadata updated 09:53:29.721 CNTRLR [Node 030] [Configuration] 62: metadata updated 09:53:29.721 CNTRLR [Node 030] [Configuration] 64: metadata updated 09:53:29.722 CNTRLR [Node 030] [Configuration] 66: metadata updated 09:53:29.724 CNTRLR [Node 030] [Configuration] 80: metadata updated 09:53:29.725 CNTRLR [Node 030] [Configuration] 81: metadata updated 09:53:29.726 CNTRLR [Node 030] [Configuration] 82: metadata updated 09:53:29.726 CNTRLR [Node 030] [Configuration] 83: metadata updated 09:53:29.727 CNTRLR [Node 030] [Configuration] 86: metadata updated 09:53:29.728 CNTRLR [Node 030] [Configuration] 87: metadata updated 09:53:29.729 CNTRLR [Node 030] [Configuration] 89: metadata updated 09:53:29.730 CNTRLR [Node 030] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:53:29.731 CNTRLR » [Node 030] querying parameter #1 value... 09:53:29.734 SERIAL » 0x010a00131e0370050125e842 (12 bytes) 09:53:29.735 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 232 └─[ConfigurationCCGet] parameter #: 1 09:53:29.741 SERIAL « [ACK] (0x06) 09:53:29.766 SERIAL « 0x0104011301e8 (6 bytes) 09:53:29.767 SERIAL » [ACK] (0x06) 09:53:29.772 DRIVER « [RES] [SendData] was sent: true 09:53:29.788 SERIAL « 0x01070013e800000201 (9 bytes) 09:53:29.789 SERIAL » [ACK] (0x06) 09:53:29.792 DRIVER « [REQ] [SendData] callback id: 232 transmit status: OK 09:53:29.799 SERIAL « 0x010b0004001e05700601010a97 (13 bytes) 09:53:29.805 CNTRLR [Node 030] [~] [Configuration] 1: 10 => 10 09:53:29.806 SERIAL » [ACK] (0x06) 09:53:29.808 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 10 09:53:29.809 CNTRLR « [Node 030] parameter #1 has value: 10 09:53:29.809 CNTRLR » [Node 030] querying parameter #2 value... 09:53:29.813 SERIAL » 0x010a00131e0370050225e940 (12 bytes) 09:53:29.813 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 233 └─[ConfigurationCCGet] parameter #: 2 09:53:29.816 SERIAL « [ACK] (0x06) 09:53:29.821 SERIAL « 0x0104011301e8 (6 bytes) 09:53:29.821 SERIAL » [ACK] (0x06) 09:53:29.822 DRIVER « [RES] [SendData] was sent: true 09:53:29.838 SERIAL « 0x01070013e900000200 (9 bytes) 09:53:29.839 SERIAL » [ACK] (0x06) 09:53:29.840 DRIVER « [REQ] [SendData] callback id: 233 transmit status: OK 09:53:29.879 SERIAL « 0x010b0004001e05700602010f91 (13 bytes) 09:53:29.885 CNTRLR [Node 030] [~] [Configuration] 2: 15 => 15 09:53:29.886 SERIAL » [ACK] (0x06) 09:53:29.889 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 15 09:53:29.891 CNTRLR « [Node 030] parameter #2 has value: 15 09:53:29.891 CNTRLR » [Node 030] querying parameter #3 value... 09:53:29.895 SERIAL » 0x010a00131e0370050325ea42 (12 bytes) 09:53:29.895 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 234 └─[ConfigurationCCGet] parameter #: 3 09:53:29.902 SERIAL « [ACK] (0x06) 09:53:29.904 SERIAL « 0x0104011301e8 (6 bytes) 09:53:29.905 SERIAL » [ACK] (0x06) 09:53:29.905 DRIVER « [RES] [SendData] was sent: true 09:53:29.920 SERIAL « 0x01070013ea00000203 (9 bytes) 09:53:29.920 SERIAL » [ACK] (0x06) 09:53:29.920 DRIVER « [REQ] [SendData] callback id: 234 transmit status: OK 09:53:29.931 SERIAL « 0x010b0004001e0570060301019e (13 bytes) 09:53:29.936 CNTRLR [Node 030] [~] [Configuration] 3: 1 => 1 09:53:29.937 SERIAL » [ACK] (0x06) 09:53:29.937 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 1 09:53:29.939 CNTRLR « [Node 030] parameter #3 has value: 1 09:53:29.939 CNTRLR » [Node 030] querying parameter #4 value... 09:53:29.944 SERIAL » 0x010a00131e0370050425eb44 (12 bytes) 09:53:29.944 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 235 └─[ConfigurationCCGet] parameter #: 4 09:53:29.946 SERIAL « [ACK] (0x06) 09:53:29.952 SERIAL « 0x0104011301e8 (6 bytes) 09:53:29.953 SERIAL » [ACK] (0x06) 09:53:29.953 DRIVER « [RES] [SendData] was sent: true 09:53:29.970 SERIAL « 0x01070013eb00000202 (9 bytes) 09:53:29.970 SERIAL » [ACK] (0x06) 09:53:29.970 DRIVER « [REQ] [SendData] callback id: 235 transmit status: OK 09:53:29.980 SERIAL « 0x010b0004001e0570060401029a (13 bytes) 09:53:29.985 CNTRLR [Node 030] [~] [Configuration] 4: 2 => 2 09:53:29.986 SERIAL » [ACK] (0x06) 09:53:29.987 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 1 value: 2 09:53:29.988 CNTRLR « [Node 030] parameter #4 has value: 2 09:53:29.988 CNTRLR » [Node 030] querying parameter #6 value... 09:53:29.993 SERIAL » 0x010a00131e0370050625ec41 (12 bytes) 09:53:29.994 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 236 └─[ConfigurationCCGet] parameter #: 6 09:53:29.996 SERIAL « [ACK] (0x06) 09:53:30.001 SERIAL « 0x0104011301e8 (6 bytes) 09:53:30.002 SERIAL » [ACK] (0x06) 09:53:30.002 DRIVER « [RES] [SendData] was sent: true 09:53:30.019 SERIAL « 0x01070013ec00000205 (9 bytes) 09:53:30.019 SERIAL » [ACK] (0x06) 09:53:30.019 DRIVER « [REQ] [SendData] callback id: 236 transmit status: OK 09:53:30.030 SERIAL « 0x010c0004001e0670060602001e83 (14 bytes) 09:53:30.035 CNTRLR [Node 030] [~] [Configuration] 6: 30 => 30 09:53:30.036 SERIAL » [ACK] (0x06) 09:53:30.037 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 2 value: 30 09:53:30.038 CNTRLR « [Node 030] parameter #6 has value: 30 09:53:30.038 CNTRLR » [Node 030] querying parameter #8 value... 09:53:30.041 SERIAL » 0x010a00131e0370050825ed4e (12 bytes) 09:53:30.042 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 237 └─[ConfigurationCCGet] parameter #: 8 09:53:30.044 SERIAL « [ACK] (0x06) 09:53:30.050 SERIAL « 0x0104011301e8 (6 bytes) 09:53:30.050 SERIAL » [ACK] (0x06) 09:53:30.051 DRIVER « [RES] [SendData] was sent: true 09:53:30.067 SERIAL « 0x01070013ed00000305 (9 bytes) 09:53:30.067 SERIAL » [ACK] (0x06) 09:53:30.068 DRIVER « [REQ] [SendData] callback id: 237 transmit status: OK 09:53:30.078 SERIAL « 0x010b0004001e05700608010094 (13 bytes) 09:53:30.086 CNTRLR [Node 030] [~] [Configuration] 8: 0 => 0 09:53:30.087 SERIAL » [ACK] (0x06) 09:53:30.088 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 0 09:53:30.089 CNTRLR « [Node 030] parameter #8 has value: 0 09:53:30.089 CNTRLR » [Node 030] querying parameter #9 value... 09:53:30.094 SERIAL » 0x010a00131e0370050925ee4c (12 bytes) 09:53:30.094 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 238 └─[ConfigurationCCGet] parameter #: 9 09:53:30.097 SERIAL « [ACK] (0x06) 09:53:30.102 SERIAL « 0x0104011301e8 (6 bytes) 09:53:30.103 SERIAL » [ACK] (0x06) 09:53:30.104 DRIVER « [RES] [SendData] was sent: true 09:53:30.119 SERIAL « 0x01070013ee00000207 (9 bytes) 09:53:30.120 SERIAL » [ACK] (0x06) 09:53:30.120 DRIVER « [REQ] [SendData] callback id: 238 transmit status: OK 09:53:30.131 SERIAL « 0x010c0004001e06700609020028ba (14 bytes) 09:53:30.136 CNTRLR [Node 030] [~] [Configuration] 9: 40 => 40 09:53:30.136 SERIAL » [ACK] (0x06) 09:53:30.137 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 2 value: 40 09:53:30.138 CNTRLR « [Node 030] parameter #9 has value: 40 09:53:30.138 CNTRLR » [Node 030] querying parameter #12 value... 09:53:30.142 SERIAL » 0x010a00131e0370050c25ef48 (12 bytes) 09:53:30.142 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 239 └─[ConfigurationCCGet] parameter #: 12 09:53:30.144 SERIAL « [ACK] (0x06) 09:53:30.151 SERIAL « 0x0104011301e8 (6 bytes) 09:53:30.151 SERIAL » [ACK] (0x06) 09:53:30.152 DRIVER « [RES] [SendData] was sent: true 09:53:30.167 SERIAL « 0x01070013ef00000206 (9 bytes) 09:53:30.168 SERIAL » [ACK] (0x06) 09:53:30.168 DRIVER « [REQ] [SendData] callback id: 239 transmit status: OK 09:53:30.178 SERIAL « 0x010b0004001e0570060c010090 (13 bytes) 09:53:30.183 CNTRLR [Node 030] [~] [Configuration] 12: 0 => 0 09:53:30.184 SERIAL » [ACK] (0x06) 09:53:30.184 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 1 value: 0 09:53:30.186 CNTRLR « [Node 030] parameter #12 has value: 0 09:53:30.186 CNTRLR » [Node 030] querying parameter #14 value... 09:53:30.189 SERIAL » 0x010a00131e0370050e25f055 (12 bytes) 09:53:30.190 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 240 └─[ConfigurationCCGet] parameter #: 14 09:53:30.196 SERIAL « [ACK] (0x06) 09:53:30.198 SERIAL « 0x0104011301e8 (6 bytes) 09:53:30.198 SERIAL » [ACK] (0x06) 09:53:30.204 DRIVER « [RES] [SendData] was sent: true 09:53:30.215 SERIAL « 0x01070013f000000318 (9 bytes) 09:53:30.215 SERIAL » [ACK] (0x06) 09:53:30.216 DRIVER « [REQ] [SendData] callback id: 240 transmit status: OK 09:53:30.226 SERIAL « 0x010b0004001e0570060e01ff6d (13 bytes) 09:53:30.231 CNTRLR [Node 030] [~] [Configuration] 14: 255 => 255 09:53:30.232 SERIAL » [ACK] (0x06) 09:53:30.235 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 255 09:53:30.237 CNTRLR « [Node 030] parameter #14 has value: 255 09:53:30.238 CNTRLR » [Node 030] querying parameter #16 value... 09:53:30.242 SERIAL » 0x010a00131e0370051025f14a (12 bytes) 09:53:30.242 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 241 └─[ConfigurationCCGet] parameter #: 16 09:53:30.244 SERIAL « [ACK] (0x06) 09:53:30.251 SERIAL « 0x0104011301e8 (6 bytes) 09:53:30.251 SERIAL » [ACK] (0x06) 09:53:30.252 DRIVER « [RES] [SendData] was sent: true 09:53:30.268 SERIAL « 0x01070013f100000218 (9 bytes) 09:53:30.268 SERIAL » [ACK] (0x06) 09:53:30.268 DRIVER « [REQ] [SendData] callback id: 241 transmit status: OK 09:53:30.278 SERIAL « 0x010b0004001e0570061001008c (13 bytes) 09:53:30.283 CNTRLR [Node 030] [~] [Configuration] 16: 0 => 0 09:53:30.284 SERIAL » [ACK] (0x06) 09:53:30.285 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 0 09:53:30.286 CNTRLR « [Node 030] parameter #16 has value: 0 09:53:30.286 CNTRLR » [Node 030] querying parameter #20 value... 09:53:30.289 SERIAL » 0x010a00131e0370051425f24d (12 bytes) 09:53:30.290 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 242 └─[ConfigurationCCGet] parameter #: 20 09:53:30.291 SERIAL « [ACK] (0x06) 09:53:30.299 SERIAL « 0x0104011301e8 (6 bytes) 09:53:30.299 SERIAL » [ACK] (0x06) 09:53:30.299 DRIVER « [RES] [SendData] was sent: true 09:53:30.315 SERIAL « 0x01070013f20000031a (9 bytes) 09:53:30.315 SERIAL » [ACK] (0x06) 09:53:30.316 DRIVER « [REQ] [SendData] callback id: 242 transmit status: OK 09:53:30.325 SERIAL « 0x010b0004001e05700614010f87 (13 bytes) 09:53:30.330 CNTRLR [Node 030] [~] [Configuration] 20: 15 => 15 09:53:30.331 SERIAL » [ACK] (0x06) 09:53:30.331 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 15 09:53:30.333 CNTRLR « [Node 030] parameter #20 has value: 15 09:53:30.333 CNTRLR » [Node 030] querying parameter #22 value... 09:53:30.337 SERIAL » 0x010a00131e0370051625f34e (12 bytes) 09:53:30.337 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 243 └─[ConfigurationCCGet] parameter #: 22 09:53:30.339 SERIAL « [ACK] (0x06) 09:53:30.345 SERIAL « 0x0104011301e8 (6 bytes) 09:53:30.345 SERIAL » [ACK] (0x06) 09:53:30.346 DRIVER « [RES] [SendData] was sent: true 09:53:30.362 SERIAL « 0x01070013f30000021a (9 bytes) 09:53:30.362 SERIAL » [ACK] (0x06) 09:53:30.363 DRIVER « [REQ] [SendData] callback id: 243 transmit status: OK 09:53:30.373 SERIAL « 0x010c0004001e0670061602001e93 (14 bytes) 09:53:30.378 CNTRLR [Node 030] [~] [Configuration] 22: 30 => 30 09:53:30.379 SERIAL » [ACK] (0x06) 09:53:30.380 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 30 09:53:30.381 CNTRLR « [Node 030] parameter #22 has value: 30 09:53:30.381 CNTRLR » [Node 030] querying parameter #24 value... 09:53:30.385 SERIAL » 0x010a00131e0370051825f447 (12 bytes) 09:53:30.385 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 244 └─[ConfigurationCCGet] parameter #: 24 09:53:30.387 SERIAL « [ACK] (0x06) 09:53:30.393 SERIAL « 0x0104011301e8 (6 bytes) 09:53:30.394 SERIAL » [ACK] (0x06) 09:53:30.394 DRIVER « [RES] [SendData] was sent: true 09:53:30.410 SERIAL « 0x01070013f40000021d (9 bytes) 09:53:30.411 SERIAL » [ACK] (0x06) 09:53:30.411 DRIVER « [REQ] [SendData] callback id: 244 transmit status: OK 09:53:30.421 SERIAL « 0x010b0004001e05700618010084 (13 bytes) 09:53:30.426 CNTRLR [Node 030] [~] [Configuration] 24: 0 => 0 09:53:30.427 SERIAL » [ACK] (0x06) 09:53:30.428 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 24 value size: 1 value: 0 09:53:30.429 CNTRLR « [Node 030] parameter #24 has value: 0 09:53:30.429 CNTRLR » [Node 030] querying parameter #26 value... 09:53:30.433 SERIAL » 0x010a00131e0370051a25f544 (12 bytes) 09:53:30.434 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 245 └─[ConfigurationCCGet] parameter #: 26 09:53:30.435 SERIAL « [ACK] (0x06) 09:53:30.441 SERIAL « 0x0104011301e8 (6 bytes) 09:53:30.442 SERIAL » [ACK] (0x06) 09:53:30.442 DRIVER « [RES] [SendData] was sent: true 09:53:30.459 SERIAL « 0x01070013f50000021c (9 bytes) 09:53:30.459 SERIAL » [ACK] (0x06) 09:53:30.459 DRIVER « [REQ] [SendData] callback id: 245 transmit status: OK 09:53:30.469 SERIAL « 0x010b0004001e0570061a010086 (13 bytes) 09:53:30.480 CNTRLR [Node 030] [~] [Configuration] 26: 0 => 0 09:53:30.481 SERIAL » [ACK] (0x06) 09:53:30.482 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 26 value size: 1 value: 0 09:53:30.483 CNTRLR « [Node 030] parameter #26 has value: 0 09:53:30.483 CNTRLR » [Node 030] querying parameter #40 value... 09:53:30.487 SERIAL » 0x010a00131e0370052825f675 (12 bytes) 09:53:30.487 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 246 └─[ConfigurationCCGet] parameter #: 40 09:53:30.488 SERIAL « [ACK] (0x06) 09:53:30.496 SERIAL « 0x0104011301e8 (6 bytes) 09:53:30.496 SERIAL » [ACK] (0x06) 09:53:30.497 DRIVER « [RES] [SendData] was sent: true 09:53:30.512 SERIAL « 0x01070013f60000021f (9 bytes) 09:53:30.512 SERIAL » [ACK] (0x06) 09:53:30.513 DRIVER « [REQ] [SendData] callback id: 246 transmit status: OK 09:53:30.523 SERIAL « 0x010c0004001e067006280200c87b (14 bytes) 09:53:30.528 CNTRLR [Node 030] [~] [Configuration] 40: 200 => 200 09:53:30.529 SERIAL » [ACK] (0x06) 09:53:30.529 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 2 value: 200 09:53:30.531 CNTRLR « [Node 030] parameter #40 has value: 200 09:53:30.531 CNTRLR » [Node 030] querying parameter #42 value... 09:53:30.534 SERIAL » 0x010a00131e0370052a25f776 (12 bytes) 09:53:30.535 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 247 └─[ConfigurationCCGet] parameter #: 42 09:53:30.536 SERIAL « [ACK] (0x06) 09:53:30.543 SERIAL « 0x0104011301e8 (6 bytes) 09:53:30.543 SERIAL » [ACK] (0x06) 09:53:30.543 DRIVER « [RES] [SendData] was sent: true 09:53:30.560 SERIAL « 0x01070013f70000021e (9 bytes) 09:53:30.560 SERIAL » [ACK] (0x06) 09:53:30.560 DRIVER « [REQ] [SendData] callback id: 247 transmit status: OK 09:53:30.571 SERIAL « 0x010c0004001e0670062a020000b1 (14 bytes) 09:53:30.576 CNTRLR [Node 030] [~] [Configuration] 42: 0 => 0 09:53:30.577 SERIAL » [ACK] (0x06) 09:53:30.577 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 0 09:53:30.579 CNTRLR « [Node 030] parameter #42 has value: 0 09:53:30.579 CNTRLR » [Node 030] querying parameter #60 value... 09:53:30.584 SERIAL » 0x010a00131e0370053c25f86f (12 bytes) 09:53:30.585 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 248 └─[ConfigurationCCGet] parameter #: 60 09:53:30.586 SERIAL « [ACK] (0x06) 09:53:30.594 SERIAL « 0x0104011301e8 (6 bytes) 09:53:30.594 SERIAL » [ACK] (0x06) 09:53:30.595 DRIVER « [RES] [SendData] was sent: true 09:53:30.610 SERIAL « 0x01070013f800000211 (9 bytes) 09:53:30.610 SERIAL » [ACK] (0x06) 09:53:30.611 DRIVER « [REQ] [SendData] callback id: 248 transmit status: OK 09:53:30.621 SERIAL « 0x010b0004001e0570063c010aaa (13 bytes) 09:53:30.626 CNTRLR [Node 030] [~] [Configuration] 60: 10 => 10 09:53:30.626 SERIAL » [ACK] (0x06) 09:53:30.627 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 1 value: 10 09:53:30.628 CNTRLR « [Node 030] parameter #60 has value: 10 09:53:30.629 CNTRLR » [Node 030] querying parameter #62 value... 09:53:30.632 SERIAL » 0x010a00131e0370053e25f96c (12 bytes) 09:53:30.633 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 249 └─[ConfigurationCCGet] parameter #: 62 09:53:30.635 SERIAL « [ACK] (0x06) 09:53:30.641 SERIAL « 0x0104011301e8 (6 bytes) 09:53:30.641 SERIAL » [ACK] (0x06) 09:53:30.642 DRIVER « [RES] [SendData] was sent: true 09:53:30.658 SERIAL « 0x01070013f900000210 (9 bytes) 09:53:30.658 SERIAL » [ACK] (0x06) 09:53:30.659 DRIVER « [REQ] [SendData] callback id: 249 transmit status: OK 09:53:30.669 SERIAL « 0x010c0004001e0670063e02038422 (14 bytes) 09:53:30.675 CNTRLR [Node 030] [~] [Configuration] 62: 900 => 900 09:53:30.677 SERIAL » [ACK] (0x06) 09:53:30.678 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 62 value size: 2 value: 900 09:53:30.679 CNTRLR « [Node 030] parameter #62 has value: 900 09:53:30.679 CNTRLR » [Node 030] querying parameter #64 value... 09:53:30.683 SERIAL » 0x010a00131e0370054025fa11 (12 bytes) 09:53:30.684 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 250 └─[ConfigurationCCGet] parameter #: 64 09:53:30.685 SERIAL « [ACK] (0x06) 09:53:30.701 SERIAL « 0x0104011301e8 (6 bytes) 09:53:30.701 SERIAL » [ACK] (0x06) 09:53:30.702 DRIVER « [RES] [SendData] was sent: true 09:53:30.709 SERIAL « 0x01070013fa00000213 (9 bytes) 09:53:30.709 SERIAL » [ACK] (0x06) 09:53:30.709 DRIVER « [REQ] [SendData] callback id: 250 transmit status: OK 09:53:30.720 SERIAL « 0x010c0004001e06700640020000db (14 bytes) 09:53:30.725 CNTRLR [Node 030] [~] [Configuration] 64: 0 => 0 09:53:30.726 SERIAL » [ACK] (0x06) 09:53:30.727 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 64 value size: 2 value: 0 09:53:30.728 CNTRLR « [Node 030] parameter #64 has value: 0 09:53:30.728 CNTRLR » [Node 030] querying parameter #66 value... 09:53:30.737 SERIAL » 0x010a00131e0370054225fb12 (12 bytes) 09:53:30.737 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 251 └─[ConfigurationCCGet] parameter #: 66 09:53:30.745 SERIAL « [ACK] (0x06) 09:53:30.747 SERIAL « 0x0104011301e8 (6 bytes) 09:53:30.747 SERIAL » [ACK] (0x06) 09:53:30.749 DRIVER « [RES] [SendData] was sent: true 09:53:30.762 SERIAL « 0x01070013fb00000212 (9 bytes) 09:53:30.763 SERIAL » [ACK] (0x06) 09:53:30.763 DRIVER « [REQ] [SendData] callback id: 251 transmit status: OK 09:53:30.774 SERIAL « 0x010c0004001e06700642020000d9 (14 bytes) 09:53:30.779 CNTRLR [Node 030] [~] [Configuration] 66: 0 => 0 09:53:30.779 SERIAL » [ACK] (0x06) 09:53:30.780 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 66 value size: 2 value: 0 09:53:30.781 CNTRLR « [Node 030] parameter #66 has value: 0 09:53:30.781 CNTRLR » [Node 030] querying parameter #80 value... 09:53:30.785 SERIAL » 0x010a00131e0370055025fc07 (12 bytes) 09:53:30.785 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 252 └─[ConfigurationCCGet] parameter #: 80 09:53:30.787 SERIAL « [ACK] (0x06) 09:53:30.793 SERIAL « 0x0104011301e8 (6 bytes) 09:53:30.793 SERIAL » [ACK] (0x06) 09:53:30.794 DRIVER « [RES] [SendData] was sent: true 09:53:30.810 SERIAL « 0x01070013fc00000215 (9 bytes) 09:53:30.811 SERIAL » [ACK] (0x06) 09:53:30.811 DRIVER « [REQ] [SendData] callback id: 252 transmit status: OK 09:53:30.821 SERIAL « 0x010b0004001e057006500100cc (13 bytes) 09:53:30.831 CNTRLR [Node 030] [~] [Configuration] 80: 0 => 0 09:53:30.832 SERIAL » [ACK] (0x06) 09:53:30.833 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 80 value size: 1 value: 0 09:53:30.835 CNTRLR « [Node 030] parameter #80 has value: 0 09:53:30.836 CNTRLR » [Node 030] querying parameter #81 value... 09:53:30.842 SERIAL » 0x010a00131e0370055125fd07 (12 bytes) 09:53:30.843 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 253 └─[ConfigurationCCGet] parameter #: 81 09:53:30.845 SERIAL « [ACK] (0x06) 09:53:30.851 SERIAL « 0x0104011301e8 (6 bytes) 09:53:30.851 SERIAL » [ACK] (0x06) 09:53:30.853 DRIVER « [RES] [SendData] was sent: true 09:53:30.868 SERIAL « 0x01070013fd00000214 (9 bytes) 09:53:30.869 SERIAL » [ACK] (0x06) 09:53:30.869 DRIVER « [REQ] [SendData] callback id: 253 transmit status: OK 09:53:30.879 SERIAL « 0x010b0004001e057006510132ff (13 bytes) 09:53:30.889 CNTRLR [Node 030] [~] [Configuration] 81: 50 => 50 09:53:30.890 SERIAL » [ACK] (0x06) 09:53:30.891 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 81 value size: 1 value: 50 09:53:30.893 CNTRLR « [Node 030] parameter #81 has value: 50 09:53:30.894 CNTRLR » [Node 030] querying parameter #82 value... 09:53:30.900 SERIAL » 0x010a00131e0370055225fe07 (12 bytes) 09:53:30.900 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 254 └─[ConfigurationCCGet] parameter #: 82 09:53:30.903 SERIAL « [ACK] (0x06) 09:53:30.911 SERIAL « 0x0104011301e8 (6 bytes) 09:53:30.911 SERIAL » [ACK] (0x06) 09:53:30.912 DRIVER « [RES] [SendData] was sent: true 09:53:30.926 SERIAL « 0x01070013fe00000316 (9 bytes) 09:53:30.926 SERIAL » [ACK] (0x06) 09:53:30.926 DRIVER « [REQ] [SendData] callback id: 254 transmit status: OK 09:53:30.937 SERIAL « 0x010c0004001e06700652020064ad (14 bytes) 09:53:30.942 CNTRLR [Node 030] [~] [Configuration] 82: 100 => 100 09:53:30.942 SERIAL » [ACK] (0x06) 09:53:30.943 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 82 value size: 2 value: 100 09:53:30.944 CNTRLR « [Node 030] parameter #82 has value: 100 09:53:30.944 CNTRLR » [Node 030] querying parameter #83 value... 09:53:30.948 SERIAL » 0x010a00131e0370055325ff07 (12 bytes) 09:53:30.948 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 255 └─[ConfigurationCCGet] parameter #: 83 09:53:30.950 SERIAL « [ACK] (0x06) 09:53:30.956 SERIAL « 0x0104011301e8 (6 bytes) 09:53:30.956 SERIAL » [ACK] (0x06) 09:53:30.957 DRIVER « [RES] [SendData] was sent: true 09:53:30.973 SERIAL « 0x01070013ff00000216 (9 bytes) 09:53:30.974 SERIAL » [ACK] (0x06) 09:53:30.974 DRIVER « [REQ] [SendData] callback id: 255 transmit status: OK 09:53:30.984 SERIAL « 0x010c0004001e067006530203e823 (14 bytes) 09:53:30.989 CNTRLR [Node 030] [~] [Configuration] 83: 1000 => 1000 09:53:30.990 SERIAL » [ACK] (0x06) 09:53:30.991 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 83 value size: 2 value: 1000 09:53:30.992 CNTRLR « [Node 030] parameter #83 has value: 1000 09:53:30.992 CNTRLR » [Node 030] querying parameter #86 value... 09:53:30.999 SERIAL » 0x010a00131e037005562501fc (12 bytes) 09:53:30.999 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 1 └─[ConfigurationCCGet] parameter #: 86 09:53:31.001 SERIAL « [ACK] (0x06) 09:53:31.007 SERIAL « 0x0104011301e8 (6 bytes) 09:53:31.008 SERIAL » [ACK] (0x06) 09:53:31.008 DRIVER « [RES] [SendData] was sent: true 09:53:31.025 SERIAL « 0x0107001301000003e9 (9 bytes) 09:53:31.025 SERIAL » [ACK] (0x06) 09:53:31.025 DRIVER « [REQ] [SendData] callback id: 1 transmit status: OK 09:53:31.035 SERIAL « 0x010b0004001e057006560112d8 (13 bytes) 09:53:31.040 CNTRLR [Node 030] [~] [Configuration] 86: 18 => 18 09:53:31.041 SERIAL » [ACK] (0x06) 09:53:31.041 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 86 value size: 1 value: 18 09:53:31.043 CNTRLR « [Node 030] parameter #86 has value: 18 09:53:31.043 CNTRLR » [Node 030] querying parameter #87 value... 09:53:31.046 SERIAL » 0x010a00131e037005572502fe (12 bytes) 09:53:31.047 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 2 └─[ConfigurationCCGet] parameter #: 87 09:53:31.048 SERIAL « [ACK] (0x06) 09:53:31.054 SERIAL « 0x0104011301e8 (6 bytes) 09:53:31.055 SERIAL » [ACK] (0x06) 09:53:31.055 DRIVER « [RES] [SendData] was sent: true 09:53:31.072 SERIAL « 0x0107001302000002eb (9 bytes) 09:53:31.072 SERIAL » [ACK] (0x06) 09:53:31.072 DRIVER « [REQ] [SendData] callback id: 2 transmit status: OK 09:53:31.082 SERIAL « 0x010b0004001e05700657011cd7 (13 bytes) 09:53:31.087 CNTRLR [Node 030] [~] [Configuration] 87: 28 => 28 09:53:31.088 SERIAL » [ACK] (0x06) 09:53:31.089 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 87 value size: 1 value: 28 09:53:31.090 CNTRLR « [Node 030] parameter #87 has value: 28 09:53:31.090 CNTRLR » [Node 030] querying parameter #89 value... 09:53:31.093 SERIAL » 0x010a00131e037005592503f1 (12 bytes) 09:53:31.094 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 3 └─[ConfigurationCCGet] parameter #: 89 09:53:31.095 SERIAL « [ACK] (0x06) 09:53:31.102 SERIAL « 0x0104011301e8 (6 bytes) 09:53:31.102 SERIAL » [ACK] (0x06) 09:53:31.103 DRIVER « [RES] [SendData] was sent: true 09:53:31.119 SERIAL « 0x0107001303000002ea (9 bytes) 09:53:31.119 SERIAL » [ACK] (0x06) 09:53:31.119 DRIVER « [REQ] [SendData] callback id: 3 transmit status: OK 09:53:31.128 SERIAL « 0x010b0004001e057006590101c4 (13 bytes) 09:53:31.133 CNTRLR [Node 030] [~] [Configuration] 89: 1 => 1 09:53:31.134 SERIAL » [ACK] (0x06) 09:53:31.134 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 89 value size: 1 value: 1 09:53:31.135 CNTRLR « [Node 030] parameter #89 has value: 1 09:53:31.136 CNTRLR [Node 030] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 09:53:31.165 SERIAL « 0x01090004001b033003ff26 (11 bytes) 09:53:31.166 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:53:31.167 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:53:31.167 SERIAL » [ACK] (0x06) 09:53:31.169 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:53:31.171 CNTRLR [Node 030] AlarmSensorCC: doing a partial interview... 09:53:31.172 CNTRLR » [Node 030] querying current value for General Purpose... 09:53:31.179 SERIAL » 0x010a00131e039c0100250447 (12 bytes) 09:53:31.179 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 4 └─[AlarmSensorCCGet] sensor type: General Purpose 09:53:31.181 SERIAL « [ACK] (0x06) 09:53:31.187 SERIAL « 0x0104011301e8 (6 bytes) 09:53:31.188 SERIAL » [ACK] (0x06) 09:53:31.188 DRIVER « [RES] [SendData] was sent: true 09:53:31.208 SERIAL « 0x01090004001b032001ff34 (11 bytes) 09:53:31.209 SERIAL » [ACK] (0x06) 09:53:31.209 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:53:31.210 CNTRLR [Node 027] treating BasicCC Set as a report 09:53:31.210 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:53:31.252 SERIAL « 0x0107001304000007e8 (9 bytes) 09:53:31.252 SERIAL » [ACK] (0x06) 09:53:31.252 DRIVER « [REQ] [SendData] callback id: 4 transmit status: OK 09:53:31.263 SERIAL « 0x010d0004001e079c021e000000006f (15 bytes) 09:53:31.264 CNTRLR [Node 030] [~] [Alarm Sensor] state[0]: false => false [Endpoint 0] 09:53:31.265 CNTRLR [Node 030] [+] [Alarm Sensor] severity[0]: undefined [Endpoint 0] 09:53:31.265 CNTRLR [Node 030] [+] [Alarm Sensor] duration[0]: undefined [Endpoint 0] 09:53:31.265 SERIAL » [ACK] (0x06) 09:53:31.266 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: false 09:53:31.268 CNTRLR « [Node 030] received current value for General Purpose: state: false 09:53:31.268 CNTRLR [Node 030] [~] [Alarm Sensor] interviewComplete: true [Endpoint 0] [internal] => true 09:53:31.269 CNTRLR [Node 030] MultiChannelAssociationCC: doing a partial interview... 09:53:31.269 CNTRLR » [Node 030] querying multi channel association group #1... 09:53:31.273 SERIAL » 0x010a00131e038e0201250556 (12 bytes) 09:53:31.273 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 5 └─[MultiChannelAssociationCCGet] group id: 1 09:53:31.275 SERIAL « [ACK] (0x06) 09:53:31.281 SERIAL « 0x0104011301e8 (6 bytes) 09:53:31.281 SERIAL » [ACK] (0x06) 09:53:31.281 DRIVER « [RES] [SendData] was sent: true 09:53:31.298 SERIAL « 0x0107001305000002ec (9 bytes) 09:53:31.298 SERIAL » [ACK] (0x06) 09:53:31.298 DRIVER « [REQ] [SendData] callback id: 5 transmit status: OK 09:53:31.310 SERIAL « 0x010c0004001e068e030105000167 (14 bytes) 09:53:31.310 SERIAL » [ACK] (0x06) 09:53:31.311 CNTRLR [Node 030] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 09:53:31.312 CNTRLR [Node 030] [~] [Multi Channel Association] nodeIds[1]: 1 => 1 09:53:31.313 CNTRLR [Node 030] [~] [Multi Channel Association] endpoints[1]: => 09:53:31.314 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: 1 endpoints: 09:53:31.315 CNTRLR « [Node 030] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 09:53:31.316 CNTRLR » [Node 030] querying multi channel association group #2... 09:53:31.319 SERIAL » 0x010a00131e038e0202250656 (12 bytes) 09:53:31.319 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 6 └─[MultiChannelAssociationCCGet] group id: 2 09:53:31.321 SERIAL « [ACK] (0x06) 09:53:31.330 SERIAL « 0x0104011301e8 (6 bytes) 09:53:31.330 SERIAL » [ACK] (0x06) 09:53:31.333 DRIVER « [RES] [SendData] was sent: true 09:53:31.345 SERIAL « 0x0107001306000003ee (9 bytes) 09:53:31.345 SERIAL » [ACK] (0x06) 09:53:31.345 DRIVER « [REQ] [SendData] callback id: 6 transmit status: OK 09:53:31.356 SERIAL « 0x010c0004001e068e030205000164 (14 bytes) 09:53:31.357 SERIAL » [ACK] (0x06) 09:53:31.361 CNTRLR [Node 030] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 09:53:31.364 CNTRLR [Node 030] [~] [Multi Channel Association] nodeIds[2]: 1 => 1 09:53:31.365 CNTRLR [Node 030] [~] [Multi Channel Association] endpoints[2]: => 09:53:31.365 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: 1 endpoints: 09:53:31.367 CNTRLR « [Node 030] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 09:53:31.367 CNTRLR » [Node 030] querying additional non-multi-channel association groups... 09:53:31.367 CNTRLR » [Node 030] querying association group #3... 09:53:31.372 SERIAL » 0x010a00131e0385020325075d (12 bytes) 09:53:31.372 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 7 └─[AssociationCCGet] group id: 3 09:53:31.375 SERIAL « [ACK] (0x06) 09:53:31.381 SERIAL « 0x0104011301e8 (6 bytes) 09:53:31.382 SERIAL » [ACK] (0x06) 09:53:31.383 DRIVER « [RES] [SendData] was sent: true 09:53:31.392 SERIAL « 0x0108000410080284076a (10 bytes) 09:53:31.392 SERIAL » [ACK] (0x06) 09:53:31.393 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:53:31.394 CNTRLR « [Node 008] received wakeup notification 09:53:31.395 CNTRLR [Node 008] The node is now awake. 09:53:31.409 SERIAL « 0x0107001307000003ef (9 bytes) 09:53:31.410 SERIAL » [ACK] (0x06) 09:53:31.410 DRIVER « [REQ] [SendData] callback id: 7 transmit status: OK 09:53:31.419 SERIAL « 0x010c0004001e068503030100016a (14 bytes) 09:53:31.419 SERIAL » [ACK] (0x06) 09:53:31.453 CNTRLR [Node 030] [~] [Association] maxNodes[3]: 1 => 1 [internal] 09:53:31.454 CNTRLR [Node 030] [~] [Association] nodeIds[3]: 1 => 1 [internal] 09:53:31.454 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 09:53:31.458 SERIAL » 0x0109001308028002250840 (11 bytes) 09:53:31.458 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 8 └─[BatteryCCGet] 09:53:31.459 CNTRLR « [Node 030] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 09:53:31.459 CNTRLR [Node 030] [~] [Association] hasLifeline: true => true [internal] 09:53:31.460 CNTRLR [Node 030] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 09:53:31.460 CNTRLR [Node 030] Interview stage completed: CommandClasses 09:53:31.460 CNTRLR [Node 030] Interview stage completed: OverwriteConfig 09:53:31.461 CNTRLR » [Node 030] requesting node neighbors... 09:53:31.468 SERIAL « 0x0108000410080284076a (10 bytes) 09:53:31.469 SERIAL » [ACK] (0x06) 09:53:31.469 SERIAL « [CAN] (0x18) 09:53:31.470 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 09:53:31.472 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:53:31.473 CNTRLR « [Node 008] received wakeup notification 09:53:31.556 SERIAL « 0x0108000410080284076a (10 bytes) 09:53:31.557 SERIAL » [ACK] (0x06) 09:53:31.557 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:53:31.558 CNTRLR « [Node 008] received wakeup notification 09:53:31.571 SERIAL » 0x0109001308028002250840 (11 bytes) 09:53:31.572 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 8 └─[BatteryCCGet] 09:53:31.573 SERIAL « [ACK] (0x06) 09:53:31.580 SERIAL « 0x0104011301e8 (6 bytes) 09:53:31.580 SERIAL » [ACK] (0x06) 09:53:31.581 DRIVER « [RES] [SendData] was sent: true 09:53:31.621 SERIAL « 0x0108000410080284076a (10 bytes) 09:53:31.621 SERIAL » [ACK] (0x06) 09:53:31.622 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:53:31.623 CNTRLR « [Node 008] received wakeup notification 09:53:31.635 SERIAL « 0x0108000410080284076a (10 bytes) 09:53:31.636 SERIAL » [ACK] (0x06) 09:53:31.637 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:53:31.638 CNTRLR « [Node 008] received wakeup notification 09:53:31.706 SERIAL « 0x010700130800000eed (9 bytes) 09:53:31.706 SERIAL » [ACK] (0x06) 09:53:31.707 DRIVER « [REQ] [SendData] callback id: 8 transmit status: OK 09:53:31.775 SERIAL « 0x0108000410080284076a (10 bytes) 09:53:31.775 SERIAL » [ACK] (0x06) 09:53:31.776 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:53:31.778 CNTRLR « [Node 008] received wakeup notification 09:53:31.850 SERIAL « 0x010900040008038003641e (11 bytes) 09:53:31.852 CNTRLR [Node 008] [~] [Battery] level: 100 => 100 [Endpoint 0] 09:53:31.853 CNTRLR [Node 008] [~] [Battery] isLow: false => false [Endpoint 0] 09:53:31.853 SERIAL » [ACK] (0x06) 09:53:31.855 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 09:53:31.861 SERIAL » 0x010700801e00000066 (9 bytes) 09:53:31.861 DRIVER » [Node 030] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:53:31.862 CNTRLR « [Node 008] received response for battery information: level: 100 09:53:31.863 CNTRLR [Node 008] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:53:31.916 SERIAL « 0x0108000410080284076a (10 bytes) 09:53:31.917 SERIAL » [ACK] (0x06) 09:53:31.917 SERIAL « [CAN] (0x18) 09:53:31.918 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 09:53:31.926 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:53:31.927 CNTRLR « [Node 008] received wakeup notification 09:53:31.930 CNTRLR [Node 008] WakeUpCC: doing a partial interview... 09:53:31.930 CNTRLR » [Node 008] retrieving wakeup interval from the device... 09:53:31.984 SERIAL « 0x0108000410080284076a (10 bytes) 09:53:31.984 SERIAL » [ACK] (0x06) 09:53:31.985 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:53:31.985 CNTRLR « [Node 008] received wakeup notification 09:53:32.018 SERIAL » 0x010700801e00000066 (9 bytes) 09:53:32.019 DRIVER » [Node 030] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:53:32.020 SERIAL « [ACK] (0x06) 09:53:32.023 SERIAL « 0x0120018065e984030000000000000000000000000000000000000000000000000 (34 bytes) 055 09:53:32.024 SERIAL » [ACK] (0x06) 09:53:32.024 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 9, 12, 14, 15, 16, 19, 24, 25, 26 09:53:32.032 SERIAL » 0x0109001308028405250942 (11 bytes) 09:53:32.032 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 9 └─[WakeUpCCIntervalGet] 09:53:32.033 CNTRLR « [Node 030] node neighbors received: 1, 3, 6, 7, 9, 12, 14, 15, 16, 19, 24, 2 5, 26 09:53:32.033 CNTRLR [Node 030] Interview stage completed: Neighbors 09:53:32.033 CNTRLR [Node 030] Interview completed 09:53:32.035 SERIAL « [ACK] (0x06) 09:53:32.041 SERIAL « 0x0104011301e8 (6 bytes) 09:53:32.041 SERIAL » [ACK] (0x06) 09:53:32.042 DRIVER « [RES] [SendData] was sent: true 09:53:32.068 SERIAL « 0x0108000410080284076a (10 bytes) 09:53:32.068 SERIAL » [ACK] (0x06) 09:53:32.069 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:53:32.069 CNTRLR « [Node 008] received wakeup notification 09:53:32.077 SERIAL « 0x0108000410080284076a (10 bytes) 09:53:32.078 SERIAL » [ACK] (0x06) 09:53:32.080 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:53:32.081 CNTRLR « [Node 008] received wakeup notification 09:53:32.127 SERIAL « 0x0108000410080284076a (10 bytes) 09:53:32.127 SERIAL » [ACK] (0x06) 09:53:32.128 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:53:32.128 CNTRLR « [Node 008] received wakeup notification 09:53:32.151 SERIAL « 0x0108000410080284076a (10 bytes) 09:53:32.152 SERIAL » [ACK] (0x06) 09:53:32.152 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:53:32.153 CNTRLR « [Node 008] received wakeup notification 09:53:32.291 SERIAL « 0x0107001309000019fb (9 bytes) 09:53:32.291 SERIAL » [ACK] (0x06) 09:53:32.291 DRIVER « [REQ] [SendData] callback id: 9 transmit status: OK 09:53:32.418 SERIAL « 0x010c0004000806840600038401fd (14 bytes) 09:53:32.418 CNTRLR [Node 008] [~] [Wake Up] wakeUpInterval: 900 => 900 [Endpoint 0] 09:53:32.419 CNTRLR [Node 008] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 09:53:32.419 SERIAL » [ACK] (0x06) 09:53:32.420 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 900 seconds controller node id: 1 09:53:32.422 CNTRLR « [Node 008] received wakeup configuration: wakeup interval: 900 seconds controller node: 1 09:53:32.422 CNTRLR [Node 008] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:53:32.458 CNTRLR [Node 008] AssociationCC: doing a partial interview... 09:53:32.458 CNTRLR [Node 008] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 09:53:32.458 CNTRLR [Node 008] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:53:32.459 CNTRLR [Node 008] BasicCC: doing a partial interview... 09:53:32.459 CNTRLR » [Node 008] querying Basic CC state... 09:53:32.463 SERIAL » 0x0109001308022002250ae2 (11 bytes) 09:53:32.463 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 10 └─[BasicCCGet] 09:53:32.464 SERIAL « [ACK] (0x06) 09:53:32.471 SERIAL « 0x0104011301e8 (6 bytes) 09:53:32.471 SERIAL » [ACK] (0x06) 09:53:32.472 DRIVER « [RES] [SendData] was sent: true 09:53:32.879 SERIAL « 0x010700130a000029c8 (9 bytes) 09:53:32.879 SERIAL » [ACK] (0x06) 09:53:32.880 DRIVER « [REQ] [SendData] callback id: 10 transmit status: OK 09:53:33.033 CNTRLR » [Node 030] Sending node back to sleep... 09:53:34.486 CNTRLR [Node 008] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 09:53:34.989 SERIAL » 0x0109001308022002250ae2 (11 bytes) 09:53:34.990 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 10 └─[BasicCCGet] 09:53:34.991 SERIAL « [ACK] (0x06) 09:53:34.998 SERIAL « 0x0104011301e8 (6 bytes) 09:53:34.999 SERIAL » [ACK] (0x06) 09:53:34.999 DRIVER « [RES] [SendData] was sent: true 09:53:35.015 SERIAL « 0x010700130a000003e2 (9 bytes) 09:53:35.015 SERIAL » [ACK] (0x06) 09:53:35.016 DRIVER « [REQ] [SendData] callback id: 10 transmit status: OK 09:53:35.025 SERIAL « 0x01090004000803200300da (11 bytes) 09:53:35.026 SERIAL » [ACK] (0x06) 09:53:35.027 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCReport] current value: 0 09:53:35.030 SERIAL » 0x010900131e028408250b5b (11 bytes) 09:53:35.030 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 11 └─[WakeUpCCNoMoreInformation] 09:53:35.031 CNTRLR « [Node 008] received Basic CC state: current value: 0 09:53:35.032 CNTRLR [Node 008] [~] [Basic] interviewComplete: true => true [Endpoint 0] [internal] 09:53:35.062 SERIAL « [ACK] (0x06) 09:53:35.067 SERIAL « 0x0104011301e8 (6 bytes) 09:53:35.067 SERIAL » [ACK] (0x06) 09:53:35.069 DRIVER « [RES] [SendData] was sent: true 09:53:35.071 CNTRLR [Node 008] BinarySensorCC: doing a partial interview... 09:53:35.071 CNTRLR » [Node 008] querying current value... 09:53:35.074 SERIAL « 0x010700130b000003e3 (9 bytes) 09:53:35.075 SERIAL » [ACK] (0x06) 09:53:35.076 DRIVER « [REQ] [SendData] callback id: 11 transmit status: OK 09:53:35.080 SERIAL » 0x0109001308023002250cf4 (11 bytes) 09:53:35.081 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 12 └─[BinarySensorCCGet] type: Any 09:53:35.082 CNTRLR [Node 030] The node is now asleep. 09:53:35.083 CNTRLR [Node 030] Node asleep 09:53:35.084 SERIAL « [ACK] (0x06) 09:53:35.089 SERIAL « 0x0104011301e8 (6 bytes) 09:53:35.089 SERIAL » [ACK] (0x06) 09:53:35.090 DRIVER « [RES] [SendData] was sent: true 09:53:35.106 SERIAL « 0x010700130c000003e4 (9 bytes) 09:53:35.106 SERIAL » [ACK] (0x06) 09:53:35.107 DRIVER « [REQ] [SendData] callback id: 12 transmit status: OK 09:53:35.116 SERIAL « 0x01090004000803300300ca (11 bytes) 09:53:35.117 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:53:35.118 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:53:35.119 SERIAL » [ACK] (0x06) 09:53:35.120 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:53:35.121 CNTRLR « [Node 008] received current value: false 09:53:35.122 CNTRLR [Node 008] [~] [Binary Sensor] interviewComplete: true [Endpoint 0] [internal] => true 09:53:35.122 CNTRLR [Node 008] MultilevelSensorCC: doing a partial interview... 09:53:35.122 CNTRLR » [Node 008] querying Air temperature sensor reading... 09:53:35.127 SERIAL » 0x010b0013080431040100250df7 (13 bytes) 09:53:35.127 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 13 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:53:35.129 SERIAL « [ACK] (0x06) 09:53:35.135 SERIAL « 0x0104011301e8 (6 bytes) 09:53:35.136 SERIAL » [ACK] (0x06) 09:53:35.136 DRIVER « [RES] [SendData] was sent: true 09:53:35.153 SERIAL « 0x010700130d000002e4 (9 bytes) 09:53:35.153 SERIAL » [ACK] (0x06) 09:53:35.154 DRIVER « [REQ] [SendData] callback id: 13 transmit status: OK 09:53:35.164 SERIAL « 0x010c00040008063105012200c927 (14 bytes) 09:53:35.165 CNTRLR [Node 008] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 09:53:35.165 CNTRLR [Node 008] [~] [Multilevel Sensor] Air temperature: 19.5 => 20.1 [Endpoint 0] 09:53:35.166 SERIAL » [ACK] (0x06) 09:53:35.167 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 20.1 09:53:35.169 CNTRLR « [Node 008] received current Air temperature sensor reading: 20.1 °C 09:53:35.169 CNTRLR » [Node 008] querying Illuminance sensor reading... 09:53:35.174 SERIAL » 0x010b0013080431040308250efe (13 bytes) 09:53:35.175 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 14 └─[MultilevelSensorCCGet] sensor type: Illuminance scale: Lux 09:53:35.176 SERIAL « [ACK] (0x06) 09:53:35.183 SERIAL « 0x0104011301e8 (6 bytes) 09:53:35.183 SERIAL » [ACK] (0x06) 09:53:35.184 DRIVER « [RES] [SendData] was sent: true 09:53:35.201 SERIAL « 0x010700130e000002e7 (9 bytes) 09:53:35.201 SERIAL » [ACK] (0x06) 09:53:35.202 DRIVER « [REQ] [SendData] callback id: 14 transmit status: OK 09:53:35.212 SERIAL « 0x010c00040008063105030a000fcb (14 bytes) 09:53:35.213 CNTRLR [Node 008] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 09:53:35.213 CNTRLR [Node 008] [~] [Multilevel Sensor] Illuminance: 12 => 15 [Endpoint 0] 09:53:35.214 SERIAL » [ACK] (0x06) 09:53:35.215 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 15 09:53:35.217 CNTRLR « [Node 008] received current Illuminance sensor reading: 15 Lux 09:53:35.217 CNTRLR [Node 008] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 09:53:35.217 CNTRLR [Node 008] ConfigurationCC: Loading configuration parameters from device confi g 09:53:35.224 CNTRLR [Node 008] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:53:35.225 CNTRLR [Node 008] [Configuration] 1: metadata updated 09:53:35.226 CNTRLR [Node 008] [Configuration] 2: metadata updated 09:53:35.227 CNTRLR [Node 008] [Configuration] 3: metadata updated 09:53:35.228 CNTRLR [Node 008] [Configuration] 4: metadata updated 09:53:35.229 CNTRLR [Node 008] [Configuration] 6: metadata updated 09:53:35.230 CNTRLR [Node 008] [Configuration] 8: metadata updated 09:53:35.232 CNTRLR [Node 008] [Configuration] 9: metadata updated 09:53:35.233 CNTRLR [Node 008] [Configuration] 12: metadata updated 09:53:35.234 CNTRLR [Node 008] [Configuration] 14: metadata updated 09:53:35.235 CNTRLR [Node 008] [Configuration] 16: metadata updated 09:53:35.236 CNTRLR [Node 008] [Configuration] 20: metadata updated 09:53:35.237 CNTRLR [Node 008] [Configuration] 22: metadata updated 09:53:35.238 CNTRLR [Node 008] [Configuration] 24: metadata updated 09:53:35.239 CNTRLR [Node 008] [Configuration] 26: metadata updated 09:53:35.240 CNTRLR [Node 008] [Configuration] 40: metadata updated 09:53:35.241 CNTRLR [Node 008] [Configuration] 42: metadata updated 09:53:35.242 CNTRLR [Node 008] [Configuration] 60: metadata updated 09:53:35.243 CNTRLR [Node 008] [Configuration] 62: metadata updated 09:53:35.244 CNTRLR [Node 008] [Configuration] 64: metadata updated 09:53:35.245 CNTRLR [Node 008] [Configuration] 66: metadata updated 09:53:35.247 CNTRLR [Node 008] [Configuration] 80: metadata updated 09:53:35.248 CNTRLR [Node 008] [Configuration] 81: metadata updated 09:53:35.249 CNTRLR [Node 008] [Configuration] 82: metadata updated 09:53:35.250 CNTRLR [Node 008] [Configuration] 83: metadata updated 09:53:35.251 CNTRLR [Node 008] [Configuration] 86: metadata updated 09:53:35.252 CNTRLR [Node 008] [Configuration] 87: metadata updated 09:53:35.253 CNTRLR [Node 008] [Configuration] 89: metadata updated 09:53:35.254 CNTRLR [Node 008] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:53:35.254 CNTRLR » [Node 008] querying parameter #1 value... 09:53:35.258 SERIAL » 0x010a00130803700501250fb3 (12 bytes) 09:53:35.259 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 15 └─[ConfigurationCCGet] parameter #: 1 09:53:35.261 SERIAL « [ACK] (0x06) 09:53:35.267 SERIAL « 0x0104011301e8 (6 bytes) 09:53:35.268 SERIAL » [ACK] (0x06) 09:53:35.269 DRIVER « [RES] [SendData] was sent: true 09:53:35.301 SERIAL « 0x010700130f000002e6 (9 bytes) 09:53:35.301 SERIAL » [ACK] (0x06) 09:53:35.302 DRIVER « [REQ] [SendData] callback id: 15 transmit status: OK 09:53:35.306 SERIAL « 0x010b0004000805700601010a81 (13 bytes) 09:53:35.312 CNTRLR [Node 008] [~] [Configuration] 1: 10 => 10 09:53:35.313 SERIAL » [ACK] (0x06) 09:53:35.333 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 10 09:53:35.335 CNTRLR « [Node 008] parameter #1 has value: 10 09:53:35.336 CNTRLR » [Node 008] querying parameter #2 value... 09:53:35.342 SERIAL » 0x010a001308037005022510af (12 bytes) 09:53:35.343 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[ConfigurationCCGet] parameter #: 2 09:53:35.362 SERIAL « [ACK] (0x06) 09:53:35.364 SERIAL « 0x0104011301e8 (6 bytes) 09:53:35.364 SERIAL » [ACK] (0x06) 09:53:35.365 DRIVER « [RES] [SendData] was sent: true 09:53:35.386 SERIAL « 0x0107001310000002f9 (9 bytes) 09:53:35.386 SERIAL » [ACK] (0x06) 09:53:35.387 DRIVER « [REQ] [SendData] callback id: 16 transmit status: OK 09:53:35.391 SERIAL « 0x010b0004000805700602010f87 (13 bytes) 09:53:35.396 CNTRLR [Node 008] [~] [Configuration] 2: 15 => 15 09:53:35.397 SERIAL » [ACK] (0x06) 09:53:35.397 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 15 09:53:35.399 CNTRLR « [Node 008] parameter #2 has value: 15 09:53:35.399 CNTRLR » [Node 008] querying parameter #3 value... 09:53:35.403 SERIAL » 0x010a001308037005032511af (12 bytes) 09:53:35.403 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 17 └─[ConfigurationCCGet] parameter #: 3 09:53:35.405 SERIAL « [ACK] (0x06) 09:53:35.411 SERIAL « 0x0104011301e8 (6 bytes) 09:53:35.412 SERIAL » [ACK] (0x06) 09:53:35.412 DRIVER « [RES] [SendData] was sent: true 09:53:35.429 SERIAL « 0x0107001311000002f8 (9 bytes) 09:53:35.430 SERIAL » [ACK] (0x06) 09:53:35.430 DRIVER « [REQ] [SendData] callback id: 17 transmit status: OK 09:53:35.442 SERIAL « 0x010b0004000805700603010188 (13 bytes) 09:53:35.455 CNTRLR [Node 008] [~] [Configuration] 3: 1 => 1 09:53:35.457 SERIAL » [ACK] (0x06) 09:53:35.465 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 1 09:53:35.468 CNTRLR « [Node 008] parameter #3 has value: 1 09:53:35.469 CNTRLR » [Node 008] querying parameter #4 value... 09:53:35.476 SERIAL » 0x010a001308037005042512ab (12 bytes) 09:53:35.477 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 18 └─[ConfigurationCCGet] parameter #: 4 09:53:35.486 SERIAL « [ACK] (0x06) 09:53:35.492 SERIAL « 0x0104011301e8 (6 bytes) 09:53:35.492 SERIAL » [ACK] (0x06) 09:53:35.497 DRIVER « [RES] [SendData] was sent: true 09:53:35.503 SERIAL « 0x0107001312000002fb (9 bytes) 09:53:35.503 SERIAL » [ACK] (0x06) 09:53:35.504 DRIVER « [REQ] [SendData] callback id: 18 transmit status: OK 09:53:35.513 SERIAL « 0x010b000400080570060401028c (13 bytes) 09:53:35.517 CNTRLR [Node 008] [~] [Configuration] 4: 2 => 2 09:53:35.518 SERIAL » [ACK] (0x06) 09:53:35.519 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 1 value: 2 09:53:35.520 CNTRLR « [Node 008] parameter #4 has value: 2 09:53:35.520 CNTRLR » [Node 008] querying parameter #6 value... 09:53:35.525 SERIAL » 0x010a001308037005062513a8 (12 bytes) 09:53:35.525 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 19 └─[ConfigurationCCGet] parameter #: 6 09:53:35.535 SERIAL « [ACK] (0x06) 09:53:35.536 SERIAL « 0x0104011301e8 (6 bytes) 09:53:35.536 SERIAL » [ACK] (0x06) 09:53:35.537 DRIVER « [RES] [SendData] was sent: true 09:53:35.551 SERIAL « 0x0107001313000002fa (9 bytes) 09:53:35.551 SERIAL » [ACK] (0x06) 09:53:35.552 DRIVER « [REQ] [SendData] callback id: 19 transmit status: OK 09:53:35.563 SERIAL « 0x010c000400080670060602001e95 (14 bytes) 09:53:35.567 CNTRLR [Node 008] [~] [Configuration] 6: 30 => 30 09:53:35.568 SERIAL » [ACK] (0x06) 09:53:35.569 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 2 value: 30 09:53:35.570 CNTRLR « [Node 008] parameter #6 has value: 30 09:53:35.572 CNTRLR » [Node 008] querying parameter #8 value... 09:53:35.575 SERIAL » 0x010a001308037005082514a1 (12 bytes) 09:53:35.576 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 20 └─[ConfigurationCCGet] parameter #: 8 09:53:35.578 SERIAL « [ACK] (0x06) 09:53:35.587 SERIAL « 0x0104011301e8 (6 bytes) 09:53:35.587 SERIAL » [ACK] (0x06) 09:53:35.588 DRIVER « [RES] [SendData] was sent: true 09:53:35.601 SERIAL « 0x0107001314000002fd (9 bytes) 09:53:35.601 SERIAL » [ACK] (0x06) 09:53:35.601 DRIVER « [REQ] [SendData] callback id: 20 transmit status: OK 09:53:35.611 SERIAL « 0x010b0004000805700608010082 (13 bytes) 09:53:35.616 CNTRLR [Node 008] [~] [Configuration] 8: 0 => 0 09:53:35.620 SERIAL » [ACK] (0x06) 09:53:35.621 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 0 09:53:35.623 CNTRLR « [Node 008] parameter #8 has value: 0 09:53:35.623 CNTRLR » [Node 008] querying parameter #9 value... 09:53:35.629 SERIAL » 0x010a001308037005092515a1 (12 bytes) 09:53:35.630 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 21 └─[ConfigurationCCGet] parameter #: 9 09:53:35.632 SERIAL « [ACK] (0x06) 09:53:35.638 SERIAL « 0x0104011301e8 (6 bytes) 09:53:35.638 SERIAL » [ACK] (0x06) 09:53:35.639 DRIVER « [RES] [SendData] was sent: true 09:53:35.655 SERIAL « 0x0107001315000003fd (9 bytes) 09:53:35.655 SERIAL » [ACK] (0x06) 09:53:35.656 DRIVER « [REQ] [SendData] callback id: 21 transmit status: OK 09:53:35.666 SERIAL « 0x010c0004000806700609020028ac (14 bytes) 09:53:35.671 CNTRLR [Node 008] [~] [Configuration] 9: 40 => 40 09:53:35.672 SERIAL » [ACK] (0x06) 09:53:35.673 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 2 value: 40 09:53:35.674 CNTRLR « [Node 008] parameter #9 has value: 40 09:53:35.674 CNTRLR » [Node 008] querying parameter #12 value... 09:53:35.678 SERIAL » 0x010a0013080370050c2516a7 (12 bytes) 09:53:35.678 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 22 └─[ConfigurationCCGet] parameter #: 12 09:53:35.681 SERIAL « [ACK] (0x06) 09:53:35.691 SERIAL « 0x0104011301e8 (6 bytes) 09:53:35.691 SERIAL » [ACK] (0x06) 09:53:35.692 DRIVER « [RES] [SendData] was sent: true 09:53:35.704 SERIAL « 0x0107001316000002ff (9 bytes) 09:53:35.704 SERIAL » [ACK] (0x06) 09:53:35.705 DRIVER « [REQ] [SendData] callback id: 22 transmit status: OK 09:53:35.714 SERIAL « 0x010b000400080570060c010086 (13 bytes) 09:53:35.720 CNTRLR [Node 008] [~] [Configuration] 12: 0 => 0 09:53:35.721 SERIAL » [ACK] (0x06) 09:53:35.723 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 1 value: 0 09:53:35.725 CNTRLR « [Node 008] parameter #12 has value: 0 09:53:35.725 CNTRLR » [Node 008] querying parameter #14 value... 09:53:35.729 SERIAL » 0x010a0013080370050e2517a4 (12 bytes) 09:53:35.730 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 23 └─[ConfigurationCCGet] parameter #: 14 09:53:35.733 SERIAL « [ACK] (0x06) 09:53:35.737 SERIAL « 0x0104011301e8 (6 bytes) 09:53:35.738 SERIAL » [ACK] (0x06) 09:53:35.738 DRIVER « [RES] [SendData] was sent: true 09:53:35.755 SERIAL « 0x0107001317000003ff (9 bytes) 09:53:35.755 SERIAL » [ACK] (0x06) 09:53:35.755 DRIVER « [REQ] [SendData] callback id: 23 transmit status: OK 09:53:35.766 SERIAL « 0x010b000400080570060e01ff7b (13 bytes) 09:53:35.771 CNTRLR [Node 008] [~] [Configuration] 14: 255 => 255 09:53:35.772 SERIAL » [ACK] (0x06) 09:53:35.772 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 255 09:53:35.774 CNTRLR « [Node 008] parameter #14 has value: 255 09:53:35.774 CNTRLR » [Node 008] querying parameter #16 value... 09:53:35.778 SERIAL » 0x010a001308037005102518b5 (12 bytes) 09:53:35.778 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 24 └─[ConfigurationCCGet] parameter #: 16 09:53:35.780 SERIAL « [ACK] (0x06) 09:53:35.786 SERIAL « 0x0104011301e8 (6 bytes) 09:53:35.787 SERIAL » [ACK] (0x06) 09:53:35.787 DRIVER « [RES] [SendData] was sent: true 09:53:35.803 SERIAL « 0x0107001318000002f1 (9 bytes) 09:53:35.804 SERIAL » [ACK] (0x06) 09:53:35.804 DRIVER « [REQ] [SendData] callback id: 24 transmit status: OK 09:53:35.814 SERIAL « 0x010b000400080570061001009a (13 bytes) 09:53:35.819 CNTRLR [Node 008] [~] [Configuration] 16: 0 => 0 09:53:35.820 SERIAL » [ACK] (0x06) 09:53:35.821 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 0 09:53:35.822 CNTRLR « [Node 008] parameter #16 has value: 0 09:53:35.822 CNTRLR » [Node 008] querying parameter #20 value... 09:53:35.826 SERIAL » 0x010a001308037005142519b0 (12 bytes) 09:53:35.826 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 25 └─[ConfigurationCCGet] parameter #: 20 09:53:35.829 SERIAL « [ACK] (0x06) 09:53:35.834 SERIAL « 0x0104011301e8 (6 bytes) 09:53:35.835 SERIAL » [ACK] (0x06) 09:53:35.835 DRIVER « [RES] [SendData] was sent: true 09:53:35.852 SERIAL « 0x0107001319000002f0 (9 bytes) 09:53:35.852 SERIAL » [ACK] (0x06) 09:53:35.852 DRIVER « [REQ] [SendData] callback id: 25 transmit status: OK 09:53:35.863 SERIAL « 0x010b0004000805700614010f91 (13 bytes) 09:53:35.868 CNTRLR [Node 008] [~] [Configuration] 20: 15 => 15 09:53:35.868 SERIAL » [ACK] (0x06) 09:53:35.874 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 15 09:53:35.875 CNTRLR « [Node 008] parameter #20 has value: 15 09:53:35.875 CNTRLR » [Node 008] querying parameter #22 value... 09:53:35.879 SERIAL » 0x010a00130803700516251ab1 (12 bytes) 09:53:35.879 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 26 └─[ConfigurationCCGet] parameter #: 22 09:53:35.881 SERIAL « [ACK] (0x06) 09:53:35.887 SERIAL « 0x0104011301e8 (6 bytes) 09:53:35.888 SERIAL » [ACK] (0x06) 09:53:35.888 DRIVER « [RES] [SendData] was sent: true 09:53:35.904 SERIAL « 0x010700131a000002f3 (9 bytes) 09:53:35.905 SERIAL » [ACK] (0x06) 09:53:35.905 DRIVER « [REQ] [SendData] callback id: 26 transmit status: OK 09:53:35.916 SERIAL « 0x010c000400080670061602001e85 (14 bytes) 09:53:35.920 CNTRLR [Node 008] [~] [Configuration] 22: 30 => 30 09:53:35.921 SERIAL » [ACK] (0x06) 09:53:35.922 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 30 09:53:35.923 CNTRLR « [Node 008] parameter #22 has value: 30 09:53:35.924 CNTRLR » [Node 008] querying parameter #24 value... 09:53:35.928 SERIAL » 0x010a00130803700518251bbe (12 bytes) 09:53:35.928 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 27 └─[ConfigurationCCGet] parameter #: 24 09:53:35.930 SERIAL « [ACK] (0x06) 09:53:35.936 SERIAL « 0x0104011301e8 (6 bytes) 09:53:35.936 SERIAL » [ACK] (0x06) 09:53:35.936 DRIVER « [RES] [SendData] was sent: true 09:53:35.953 SERIAL « 0x010700131b000002f2 (9 bytes) 09:53:35.953 SERIAL » [ACK] (0x06) 09:53:35.954 DRIVER « [REQ] [SendData] callback id: 27 transmit status: OK 09:53:35.964 SERIAL « 0x010b0004000805700618010092 (13 bytes) 09:53:35.969 CNTRLR [Node 008] [~] [Configuration] 24: 0 => 0 09:53:35.969 SERIAL » [ACK] (0x06) 09:53:35.970 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 24 value size: 1 value: 0 09:53:35.971 CNTRLR « [Node 008] parameter #24 has value: 0 09:53:35.972 CNTRLR » [Node 008] querying parameter #26 value... 09:53:35.975 SERIAL » 0x010a0013080370051a251cbb (12 bytes) 09:53:35.975 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 28 └─[ConfigurationCCGet] parameter #: 26 09:53:35.978 SERIAL « [ACK] (0x06) 09:53:35.983 SERIAL « 0x0104011301e8 (6 bytes) 09:53:35.984 SERIAL » [ACK] (0x06) 09:53:35.985 DRIVER « [RES] [SendData] was sent: true 09:53:36.001 SERIAL « 0x010700131c000002f5 (9 bytes) 09:53:36.001 SERIAL » [ACK] (0x06) 09:53:36.001 DRIVER « [REQ] [SendData] callback id: 28 transmit status: OK 09:53:36.011 SERIAL « 0x010b000400080570061a010090 (13 bytes) 09:53:36.016 CNTRLR [Node 008] [~] [Configuration] 26: 0 => 0 09:53:36.017 SERIAL » [ACK] (0x06) 09:53:36.018 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 26 value size: 1 value: 0 09:53:36.019 CNTRLR « [Node 008] parameter #26 has value: 0 09:53:36.019 CNTRLR » [Node 008] querying parameter #40 value... 09:53:36.023 SERIAL » 0x010a00130803700528251d88 (12 bytes) 09:53:36.023 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 29 └─[ConfigurationCCGet] parameter #: 40 09:53:36.027 SERIAL « [ACK] (0x06) 09:53:36.031 SERIAL « 0x0104011301e8 (6 bytes) 09:53:36.031 SERIAL » [ACK] (0x06) 09:53:36.032 DRIVER « [RES] [SendData] was sent: true 09:53:36.048 SERIAL « 0x010700131d000002f4 (9 bytes) 09:53:36.049 SERIAL » [ACK] (0x06) 09:53:36.049 DRIVER « [REQ] [SendData] callback id: 29 transmit status: OK 09:53:36.059 SERIAL « 0x010c00040008067006280200c86d (14 bytes) 09:53:36.064 CNTRLR [Node 008] [~] [Configuration] 40: 200 => 200 09:53:36.065 SERIAL » [ACK] (0x06) 09:53:36.065 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 2 value: 200 09:53:36.067 CNTRLR « [Node 008] parameter #40 has value: 200 09:53:36.067 CNTRLR » [Node 008] querying parameter #42 value... 09:53:36.070 SERIAL » 0x010a0013080370052a251e89 (12 bytes) 09:53:36.071 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 30 └─[ConfigurationCCGet] parameter #: 42 09:53:36.075 SERIAL « [ACK] (0x06) 09:53:36.079 SERIAL « 0x0104011301e8 (6 bytes) 09:53:36.079 SERIAL » [ACK] (0x06) 09:53:36.080 DRIVER « [RES] [SendData] was sent: true 09:53:36.096 SERIAL « 0x010700131e000003f6 (9 bytes) 09:53:36.096 SERIAL » [ACK] (0x06) 09:53:36.097 DRIVER « [REQ] [SendData] callback id: 30 transmit status: OK 09:53:36.107 SERIAL « 0x010c000400080670062a020000a7 (14 bytes) 09:53:36.112 CNTRLR [Node 008] [~] [Configuration] 42: 0 => 0 09:53:36.112 SERIAL » [ACK] (0x06) 09:53:36.113 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 0 09:53:36.114 CNTRLR « [Node 008] parameter #42 has value: 0 09:53:36.115 CNTRLR » [Node 008] querying parameter #60 value... 09:53:36.118 SERIAL » 0x010a0013080370053c251f9e (12 bytes) 09:53:36.118 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 31 └─[ConfigurationCCGet] parameter #: 60 09:53:36.121 SERIAL « [ACK] (0x06) 09:53:36.126 SERIAL « 0x0104011301e8 (6 bytes) 09:53:36.127 SERIAL » [ACK] (0x06) 09:53:36.127 DRIVER « [RES] [SendData] was sent: true 09:53:36.144 SERIAL « 0x010700131f000002f6 (9 bytes) 09:53:36.144 SERIAL » [ACK] (0x06) 09:53:36.145 DRIVER « [REQ] [SendData] callback id: 31 transmit status: OK 09:53:36.154 SERIAL « 0x010b000400080570063c010abc (13 bytes) 09:53:36.159 CNTRLR [Node 008] [~] [Configuration] 60: 10 => 10 09:53:36.160 SERIAL » [ACK] (0x06) 09:53:36.161 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 1 value: 10 09:53:36.162 CNTRLR « [Node 008] parameter #60 has value: 10 09:53:36.162 CNTRLR » [Node 008] querying parameter #62 value... 09:53:36.166 SERIAL » 0x010a0013080370053e2520a3 (12 bytes) 09:53:36.166 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 32 └─[ConfigurationCCGet] parameter #: 62 09:53:36.168 SERIAL « [ACK] (0x06) 09:53:36.174 SERIAL « 0x0104011301e8 (6 bytes) 09:53:36.175 SERIAL » [ACK] (0x06) 09:53:36.175 DRIVER « [RES] [SendData] was sent: true 09:53:36.192 SERIAL « 0x0107001320000002c9 (9 bytes) 09:53:36.192 SERIAL » [ACK] (0x06) 09:53:36.192 DRIVER « [REQ] [SendData] callback id: 32 transmit status: OK 09:53:36.203 SERIAL « 0x010c000400080670063e02038434 (14 bytes) 09:53:36.207 CNTRLR [Node 008] [~] [Configuration] 62: 900 => 900 09:53:36.209 SERIAL » [ACK] (0x06) 09:53:36.209 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 62 value size: 2 value: 900 09:53:36.210 CNTRLR « [Node 008] parameter #62 has value: 900 09:53:36.211 CNTRLR » [Node 008] querying parameter #64 value... 09:53:36.214 SERIAL » 0x010a001308037005402521dc (12 bytes) 09:53:36.215 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 33 └─[ConfigurationCCGet] parameter #: 64 09:53:36.218 SERIAL « [ACK] (0x06) 09:53:36.222 SERIAL « 0x0104011301e8 (6 bytes) 09:53:36.223 SERIAL » [ACK] (0x06) 09:53:36.223 DRIVER « [RES] [SendData] was sent: true 09:53:36.240 SERIAL « 0x0107001321000002c8 (9 bytes) 09:53:36.240 SERIAL » [ACK] (0x06) 09:53:36.241 DRIVER « [REQ] [SendData] callback id: 33 transmit status: OK 09:53:36.251 SERIAL « 0x010c0004000806700640020000cd (14 bytes) 09:53:36.258 CNTRLR [Node 008] [~] [Configuration] 64: 0 => 0 09:53:36.259 SERIAL » [ACK] (0x06) 09:53:36.260 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 64 value size: 2 value: 0 09:53:36.262 CNTRLR « [Node 008] parameter #64 has value: 0 09:53:36.262 CNTRLR » [Node 008] querying parameter #66 value... 09:53:36.267 SERIAL » 0x010a001308037005422522dd (12 bytes) 09:53:36.268 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 34 └─[ConfigurationCCGet] parameter #: 66 09:53:36.272 SERIAL « [ACK] (0x06) 09:53:36.285 SERIAL « 0x0104011301e8 (6 bytes) 09:53:36.286 SERIAL » [ACK] (0x06) 09:53:36.287 DRIVER « [RES] [SendData] was sent: true 09:53:36.293 SERIAL « 0x0107001322000002cb (9 bytes) 09:53:36.293 SERIAL » [ACK] (0x06) 09:53:36.294 DRIVER « [REQ] [SendData] callback id: 34 transmit status: OK 09:53:36.304 SERIAL « 0x010c0004000806700642020000cf (14 bytes) 09:53:36.311 CNTRLR [Node 008] [~] [Configuration] 66: 0 => 0 09:53:36.312 SERIAL » [ACK] (0x06) 09:53:36.313 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 66 value size: 2 value: 0 09:53:36.314 CNTRLR « [Node 008] parameter #66 has value: 0 09:53:36.315 CNTRLR » [Node 008] querying parameter #80 value... 09:53:36.320 SERIAL » 0x010a001308037005502523ce (12 bytes) 09:53:36.320 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 35 └─[ConfigurationCCGet] parameter #: 80 09:53:36.323 SERIAL « [ACK] (0x06) 09:53:36.328 SERIAL « 0x0104011301e8 (6 bytes) 09:53:36.329 SERIAL » [ACK] (0x06) 09:53:36.329 DRIVER « [RES] [SendData] was sent: true 09:53:36.345 SERIAL « 0x0107001323000003cb (9 bytes) 09:53:36.346 SERIAL » [ACK] (0x06) 09:53:36.346 DRIVER « [REQ] [SendData] callback id: 35 transmit status: OK 09:53:36.356 SERIAL « 0x010b00040008057006500100da (13 bytes) 09:53:36.363 CNTRLR [Node 008] [~] [Configuration] 80: 0 => 0 09:53:36.365 SERIAL » [ACK] (0x06) 09:53:36.365 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 80 value size: 1 value: 0 09:53:36.367 CNTRLR « [Node 008] parameter #80 has value: 0 09:53:36.367 CNTRLR » [Node 008] querying parameter #81 value... 09:53:36.393 SERIAL » 0x010a001308037005512524c8 (12 bytes) 09:53:36.394 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 36 └─[ConfigurationCCGet] parameter #: 81 09:53:36.399 SERIAL « [ACK] (0x06) 09:53:36.409 SERIAL « 0x0104011301e8 (6 bytes) 09:53:36.409 SERIAL » [ACK] (0x06) 09:53:36.413 DRIVER « [RES] [SendData] was sent: true 09:53:36.419 SERIAL « 0x0107001324000002cd (9 bytes) 09:53:36.420 SERIAL » [ACK] (0x06) 09:53:36.420 DRIVER « [REQ] [SendData] callback id: 36 transmit status: OK 09:53:36.430 SERIAL « 0x010b00040008057006510132e9 (13 bytes) 09:53:36.438 CNTRLR [Node 008] [~] [Configuration] 81: 50 => 50 09:53:36.439 SERIAL » [ACK] (0x06) 09:53:36.440 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 81 value size: 1 value: 50 09:53:36.441 CNTRLR « [Node 008] parameter #81 has value: 50 09:53:36.442 CNTRLR » [Node 008] querying parameter #82 value... 09:53:36.446 SERIAL » 0x010a001308037005522525ca (12 bytes) 09:53:36.447 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 37 └─[ConfigurationCCGet] parameter #: 82 09:53:36.449 SERIAL « [ACK] (0x06) 09:53:36.454 SERIAL « 0x0104011301e8 (6 bytes) 09:53:36.455 SERIAL » [ACK] (0x06) 09:53:36.455 DRIVER « [RES] [SendData] was sent: true 09:53:36.472 SERIAL « 0x0107001325000002cc (9 bytes) 09:53:36.472 SERIAL » [ACK] (0x06) 09:53:36.472 DRIVER « [REQ] [SendData] callback id: 37 transmit status: OK 09:53:36.483 SERIAL « 0x010c0004000806700652020064bb (14 bytes) 09:53:36.488 CNTRLR [Node 008] [~] [Configuration] 82: 100 => 100 09:53:36.502 SERIAL » [ACK] (0x06) 09:53:36.503 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 82 value size: 2 value: 100 09:53:36.505 CNTRLR « [Node 008] parameter #82 has value: 100 09:53:36.505 CNTRLR » [Node 008] querying parameter #83 value... 09:53:36.509 SERIAL » 0x010a001308037005532526c8 (12 bytes) 09:53:36.509 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 38 └─[ConfigurationCCGet] parameter #: 83 09:53:36.511 SERIAL « [ACK] (0x06) 09:53:36.518 SERIAL « 0x0104011301e8 (6 bytes) 09:53:36.518 SERIAL » [ACK] (0x06) 09:53:36.519 DRIVER « [RES] [SendData] was sent: true 09:53:36.534 SERIAL « 0x0107001326000002cf (9 bytes) 09:53:36.534 SERIAL » [ACK] (0x06) 09:53:36.535 DRIVER « [REQ] [SendData] callback id: 38 transmit status: OK 09:53:36.545 SERIAL « 0x010c00040008067006530203e835 (14 bytes) 09:53:36.550 CNTRLR [Node 008] [~] [Configuration] 83: 1000 => 1000 09:53:36.551 SERIAL » [ACK] (0x06) 09:53:36.551 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 83 value size: 2 value: 1000 09:53:36.553 CNTRLR « [Node 008] parameter #83 has value: 1000 09:53:36.553 CNTRLR » [Node 008] querying parameter #86 value... 09:53:36.556 SERIAL » 0x010a001308037005562527cc (12 bytes) 09:53:36.557 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[ConfigurationCCGet] parameter #: 86 09:53:36.559 SERIAL « [ACK] (0x06) 09:53:36.565 SERIAL « 0x0104011301e8 (6 bytes) 09:53:36.565 SERIAL » [ACK] (0x06) 09:53:36.565 DRIVER « [RES] [SendData] was sent: true 09:53:36.582 SERIAL « 0x0107001327000002ce (9 bytes) 09:53:36.582 SERIAL » [ACK] (0x06) 09:53:36.582 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 09:53:36.593 SERIAL « 0x010b00040008057006560112ce (13 bytes) 09:53:36.598 CNTRLR [Node 008] [~] [Configuration] 86: 18 => 18 09:53:36.598 SERIAL » [ACK] (0x06) 09:53:36.599 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 86 value size: 1 value: 18 09:53:36.600 CNTRLR « [Node 008] parameter #86 has value: 18 09:53:36.601 CNTRLR » [Node 008] querying parameter #87 value... 09:53:36.604 SERIAL » 0x010a001308037005572528c2 (12 bytes) 09:53:36.604 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 40 └─[ConfigurationCCGet] parameter #: 87 09:53:36.608 SERIAL « [ACK] (0x06) 09:53:36.613 SERIAL « 0x0104011301e8 (6 bytes) 09:53:36.615 SERIAL » [ACK] (0x06) 09:53:36.616 DRIVER « [RES] [SendData] was sent: true 09:53:36.630 SERIAL « 0x0107001328000002c1 (9 bytes) 09:53:36.630 SERIAL » [ACK] (0x06) 09:53:36.630 DRIVER « [REQ] [SendData] callback id: 40 transmit status: OK 09:53:36.640 SERIAL « 0x010b0004000805700657011cc1 (13 bytes) 09:53:36.645 CNTRLR [Node 008] [~] [Configuration] 87: 28 => 28 09:53:36.646 SERIAL » [ACK] (0x06) 09:53:36.647 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 87 value size: 1 value: 28 09:53:36.648 CNTRLR « [Node 008] parameter #87 has value: 28 09:53:36.648 CNTRLR » [Node 008] querying parameter #89 value... 09:53:36.652 SERIAL » 0x010a001308037005592529cd (12 bytes) 09:53:36.652 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 41 └─[ConfigurationCCGet] parameter #: 89 09:53:36.655 SERIAL « [ACK] (0x06) 09:53:36.660 SERIAL « 0x0104011301e8 (6 bytes) 09:53:36.661 SERIAL » [ACK] (0x06) 09:53:36.661 DRIVER « [RES] [SendData] was sent: true 09:53:36.677 SERIAL « 0x0107001329000002c0 (9 bytes) 09:53:36.678 SERIAL » [ACK] (0x06) 09:53:36.678 DRIVER « [REQ] [SendData] callback id: 41 transmit status: OK 09:53:36.688 SERIAL « 0x010b00040008057006590101d2 (13 bytes) 09:53:36.693 CNTRLR [Node 008] [~] [Configuration] 89: 1 => 1 09:53:36.694 SERIAL » [ACK] (0x06) 09:53:36.694 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 89 value size: 1 value: 1 09:53:36.696 CNTRLR « [Node 008] parameter #89 has value: 1 09:53:36.696 CNTRLR [Node 008] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 09:53:36.731 CNTRLR [Node 008] AlarmSensorCC: doing a partial interview... 09:53:36.731 CNTRLR » [Node 008] querying current value for General Purpose... 09:53:36.736 SERIAL » 0x010a001308039c0100252a7f (12 bytes) 09:53:36.736 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 42 └─[AlarmSensorCCGet] sensor type: General Purpose 09:53:36.738 SERIAL « [ACK] (0x06) 09:53:36.744 SERIAL « 0x0104011301e8 (6 bytes) 09:53:36.744 SERIAL » [ACK] (0x06) 09:53:36.744 DRIVER « [RES] [SendData] was sent: true 09:53:36.761 SERIAL « 0x010700132a000002c3 (9 bytes) 09:53:36.761 SERIAL » [ACK] (0x06) 09:53:36.761 DRIVER « [REQ] [SendData] callback id: 42 transmit status: OK 09:53:36.773 SERIAL « 0x010d00040008079c0208000000006f (15 bytes) 09:53:36.774 CNTRLR [Node 008] [~] [Alarm Sensor] state[0]: false => false [Endpoint 0] 09:53:36.774 CNTRLR [Node 008] [+] [Alarm Sensor] severity[0]: undefined [Endpoint 0] 09:53:36.775 CNTRLR [Node 008] [+] [Alarm Sensor] duration[0]: undefined [Endpoint 0] 09:53:36.775 SERIAL » [ACK] (0x06) 09:53:36.776 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: false 09:53:36.778 CNTRLR « [Node 008] received current value for General Purpose: state: false 09:53:36.778 CNTRLR [Node 008] [~] [Alarm Sensor] interviewComplete: true [Endpoint 0] [internal] => true 09:53:36.778 CNTRLR [Node 008] MultiChannelAssociationCC: doing a partial interview... 09:53:36.779 CNTRLR » [Node 008] querying multi channel association group #1... 09:53:36.782 SERIAL » 0x010a001308038e0201252b6e (12 bytes) 09:53:36.783 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 43 └─[MultiChannelAssociationCCGet] group id: 1 09:53:36.785 SERIAL « [ACK] (0x06) 09:53:36.791 SERIAL « 0x0104011301e8 (6 bytes) 09:53:36.791 SERIAL » [ACK] (0x06) 09:53:36.791 DRIVER « [RES] [SendData] was sent: true 09:53:36.808 SERIAL « 0x010700132b000002c2 (9 bytes) 09:53:36.808 SERIAL » [ACK] (0x06) 09:53:36.809 DRIVER « [REQ] [SendData] callback id: 43 transmit status: OK 09:53:36.819 SERIAL « 0x010c00040008068e030105000171 (14 bytes) 09:53:36.820 SERIAL » [ACK] (0x06) 09:53:36.820 CNTRLR [Node 008] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 09:53:36.821 CNTRLR [Node 008] [~] [Multi Channel Association] nodeIds[1]: 1 => 1 09:53:36.822 CNTRLR [Node 008] [~] [Multi Channel Association] endpoints[1]: => 09:53:36.823 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: 1 endpoints: 09:53:36.825 CNTRLR « [Node 008] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 09:53:36.825 CNTRLR » [Node 008] querying multi channel association group #2... 09:53:36.828 SERIAL » 0x010a001308038e0202252c6a (12 bytes) 09:53:36.829 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 44 └─[MultiChannelAssociationCCGet] group id: 2 09:53:36.830 SERIAL « [ACK] (0x06) 09:53:36.839 SERIAL « 0x0104011301e8 (6 bytes) 09:53:36.839 SERIAL » [ACK] (0x06) 09:53:36.840 DRIVER « [RES] [SendData] was sent: true 09:53:36.854 SERIAL « 0x010700132c000002c5 (9 bytes) 09:53:36.854 SERIAL » [ACK] (0x06) 09:53:36.867 DRIVER « [REQ] [SendData] callback id: 44 transmit status: OK 09:53:36.869 SERIAL « 0x010c00040008068e030205000172 (14 bytes) 09:53:36.869 SERIAL » [ACK] (0x06) 09:53:36.870 CNTRLR [Node 008] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 09:53:36.871 CNTRLR [Node 008] [~] [Multi Channel Association] nodeIds[2]: 1 => 1 09:53:36.872 CNTRLR [Node 008] [~] [Multi Channel Association] endpoints[2]: => 09:53:36.873 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: 1 endpoints: 09:53:36.874 CNTRLR « [Node 008] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 09:53:36.874 CNTRLR » [Node 008] querying additional non-multi-channel association groups... 09:53:36.874 CNTRLR » [Node 008] querying association group #3... 09:53:36.878 SERIAL » 0x010a00130803850203252d61 (12 bytes) 09:53:36.879 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 45 └─[AssociationCCGet] group id: 3 09:53:36.883 SERIAL « [ACK] (0x06) 09:53:36.891 SERIAL « 0x0104011301e8 (6 bytes) 09:53:36.891 SERIAL » [ACK] (0x06) 09:53:36.892 DRIVER « [RES] [SendData] was sent: true 09:53:36.904 SERIAL « 0x010700132d000002c4 (9 bytes) 09:53:36.904 SERIAL » [ACK] (0x06) 09:53:36.904 DRIVER « [REQ] [SendData] callback id: 45 transmit status: OK 09:53:36.915 SERIAL « 0x010c00040008068503030100017c (14 bytes) 09:53:36.916 SERIAL » [ACK] (0x06) 09:53:36.916 CNTRLR [Node 008] [~] [Association] maxNodes[3]: 1 => 1 [internal] 09:53:36.917 CNTRLR [Node 008] [~] [Association] nodeIds[3]: 1 => 1 [internal] 09:53:36.917 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 09:53:36.918 CNTRLR « [Node 008] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 09:53:36.919 CNTRLR [Node 008] [~] [Association] hasLifeline: true => true [internal] 09:53:36.919 CNTRLR [Node 008] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 09:53:36.948 CNTRLR [Node 008] Interview stage completed: CommandClasses 09:53:36.949 CNTRLR [Node 008] Interview stage completed: OverwriteConfig 09:53:36.949 CNTRLR » [Node 008] requesting node neighbors... 09:53:36.953 SERIAL » 0x010700800800000070 (9 bytes) 09:53:36.953 DRIVER » [Node 008] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:53:36.954 SERIAL « [ACK] (0x06) 09:53:36.958 SERIAL « 0x01200180050000000000000000000000000000000000000000000000000000000 (34 bytes) 05b 09:53:36.959 SERIAL » [ACK] (0x06) 09:53:36.960 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3 09:53:36.962 CNTRLR « [Node 008] node neighbors received: 1, 3 09:53:36.962 CNTRLR [Node 008] Interview stage completed: Neighbors 09:53:36.963 CNTRLR [Node 008] Interview completed 09:53:37.964 CNTRLR » [Node 008] Sending node back to sleep... 09:53:37.971 SERIAL » 0x0109001308028408252e68 (11 bytes) 09:53:37.972 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 46 └─[WakeUpCCNoMoreInformation] 09:53:37.974 SERIAL « [ACK] (0x06) 09:53:37.980 SERIAL « 0x0104011301e8 (6 bytes) 09:53:37.980 SERIAL » [ACK] (0x06) 09:53:37.981 DRIVER « [RES] [SendData] was sent: true 09:53:37.997 SERIAL « 0x010700132e000002c7 (9 bytes) 09:53:37.997 SERIAL » [ACK] (0x06) 09:53:37.998 DRIVER « [REQ] [SendData] callback id: 46 transmit status: OK 09:53:38.002 CNTRLR [Node 008] The node is now asleep. 09:53:38.004 CNTRLR [Node 008] Node asleep 09:53:40.633 SERIAL « 0x0108000400060298402f (10 bytes) 09:53:40.633 SERIAL » [ACK] (0x06) 09:53:40.634 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 09:53:40.639 SERIAL » 0x01110013060a98806bd7cc375cfc239b240092 (19 bytes) 09:53:40.639 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x6bd7cc375cfc239b 09:53:40.641 SERIAL « [ACK] (0x06) 09:53:40.648 SERIAL « 0x0104011301e8 (6 bytes) 09:53:40.648 SERIAL » [ACK] (0x06) 09:53:40.649 DRIVER « [RES] [SendData] was sent: true 09:53:40.691 SERIAL « 0x0124000400061e9881bc30945921fef877c79d7e416f75977b2130f76b74ac59d (38 bytes) 21019c4135c 09:53:40.692 SERIAL » [ACK] (0x06) 09:53:40.696 CNTRLR [Node 006] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:53:40.696 CNTRLR [Node 006] [~] [Multilevel Sensor] Air temperature: 21.1 => 20.5 [Endpoint 2] 09:53:40.697 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 20.5 09:53:44.222 SERIAL « 0x01090004000703300300c5 (11 bytes) 09:53:44.223 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:53:44.224 CNTRLR [Node 007] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:53:44.225 SERIAL » [ACK] (0x06) 09:53:44.227 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:53:44.407 SERIAL « 0x010c0004000306310504220519fc (14 bytes) 09:53:44.408 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:53:44.409 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 246.7 => 130.5 [Endpoint 0] 09:53:44.410 SERIAL » [ACK] (0x06) 09:53:44.412 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 130.5 09:53:44.444 SERIAL « 0x0110000400070a7105000000ff070000006a (18 bytes) 09:53:44.445 SERIAL » [ACK] (0x06) 09:53:44.447 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) 09:53:44.485 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 09:53:47.407 SERIAL « 0x010c0004000306310504220430d4 (14 bytes) 09:53:47.408 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:53:47.410 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 130.5 => 107.2 [Endpoint 0] 09:53:47.410 SERIAL » [ACK] (0x06) 09:53:47.412 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 107.2 09:53:49.407 SERIAL « 0x010c0004000306310504220512f7 (14 bytes) 09:53:49.408 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:53:49.410 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 107.2 => 129.8 [Endpoint 0] 09:53:49.411 SERIAL » [ACK] (0x06) 09:53:49.412 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 129.8 09:53:51.407 SERIAL « 0x010c0004000306310504220a9872 (14 bytes) 09:53:51.409 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:53:51.410 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 129.8 => 271.2 [Endpoint 0] 09:53:51.411 SERIAL » [ACK] (0x06) 09:53:51.412 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 271.2 09:53:52.407 SERIAL « 0x010c000400030631050422046387 (14 bytes) 09:53:52.408 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:53:52.409 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 271.2 => 112.3 [Endpoint 0] 09:53:52.410 SERIAL » [ACK] (0x06) 09:53:52.412 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 112.3 09:53:58.146 SERIAL « 0x01090004001e03300300dc (11 bytes) 09:53:58.147 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:53:58.147 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:53:58.148 SERIAL » [ACK] (0x06) 09:53:58.148 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:53:58.212 SERIAL « 0x01090004001e03200100ce (11 bytes) 09:53:58.213 SERIAL » [ACK] (0x06) 09:53:58.214 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:53:58.215 CNTRLR [Node 030] treating BasicCC Set as a report 09:53:58.215 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:53:58.786 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 09:53:58.787 SERIAL » [ACK] (0x06) 09:53:58.788 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  09:53:58.790 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 09:54:03.409 SERIAL « 0x010c0004000306310504220958b1 (14 bytes) 09:54:03.410 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:54:03.411 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 112.3 => 239.2 [Endpoint 0] 09:54:03.412 SERIAL » [ACK] (0x06) 09:54:03.414 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 239.2 09:54:09.917 SERIAL « 0x01090004001b03300300d9 (11 bytes) 09:54:09.918 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:54:09.919 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:54:09.920 SERIAL » [ACK] (0x06) 09:54:09.921 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:54:09.972 SERIAL « 0x01090004001b03200100cb (11 bytes) 09:54:09.973 SERIAL » [ACK] (0x06) 09:54:09.974 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:54:09.975 CNTRLR [Node 027] treating BasicCC Set as a report 09:54:09.976 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:54:15.410 SERIAL « 0x010c0004000306310504220506e3 (14 bytes) 09:54:15.412 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:54:15.413 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 239.2 => 128.6 [Endpoint 0] 09:54:15.414 SERIAL » [ACK] (0x06) 09:54:15.415 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 128.6 09:54:23.411 SERIAL « 0x010c0004000306310504220a5bb1 (14 bytes) 09:54:23.411 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:54:23.412 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 128.6 => 265.1 [Endpoint 0] 09:54:23.412 SERIAL » [ACK] (0x06) 09:54:23.413 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 265.1 09:54:24.411 SERIAL « 0x010c000400030631050422044aae (14 bytes) 09:54:24.411 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:54:24.412 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 265.1 => 109.8 [Endpoint 0] 09:54:24.413 SERIAL » [ACK] (0x06) 09:54:24.414 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 109.8 09:54:29.411 SERIAL « 0x010c0004000306310504220541a4 (14 bytes) 09:54:29.413 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:54:29.414 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 109.8 => 134.5 [Endpoint 0] 09:54:29.415 SERIAL » [ACK] (0x06) 09:54:29.416 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 134.5 09:54:30.411 SERIAL « 0x010c00040003063105042208866e (14 bytes) 09:54:30.412 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:54:30.413 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 134.5 => 218.2 [Endpoint 0] 09:54:30.417 SERIAL » [ACK] (0x06) 09:54:30.418 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 218.2 09:54:40.994 SERIAL « 0x01080004001502840767 (10 bytes) 09:54:40.995 SERIAL » [ACK] (0x06) 09:54:40.996 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:54:40.999 CNTRLR « [Node 021] received wakeup notification 09:54:41.000 CNTRLR [Node 021] The node is now awake. 09:54:41.010 SERIAL » 0x0109001315028002252f7a (11 bytes) 09:54:41.010 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 47 └─[BatteryCCGet] 09:54:41.013 SERIAL « [ACK] (0x06) 09:54:41.018 SERIAL « 0x0104011301e8 (6 bytes) 09:54:41.019 SERIAL » [ACK] (0x06) 09:54:41.020 DRIVER « [RES] [SendData] was sent: true 09:54:41.075 SERIAL « 0x010700132f000006c2 (9 bytes) 09:54:41.075 SERIAL » [ACK] (0x06) 09:54:41.076 DRIVER « [REQ] [SendData] callback id: 47 transmit status: OK 09:54:41.123 SERIAL « 0x0109000400150380036403 (11 bytes) 09:54:41.125 CNTRLR [Node 021] [~] [Battery] level: 100 => 100 [Endpoint 0] 09:54:41.126 CNTRLR [Node 021] [~] [Battery] isLow: false => false [Endpoint 0] 09:54:41.126 SERIAL » [ACK] (0x06) 09:54:41.128 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 09:54:41.130 CNTRLR « [Node 021] received response for battery information: level: 100 09:54:41.134 CNTRLR [Node 021] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:54:41.200 CNTRLR [Node 021] WakeUpCC: doing a partial interview... 09:54:41.201 CNTRLR » [Node 021] retrieving wakeup interval from the device... 09:54:41.208 SERIAL » 0x0109001315028405253066 (11 bytes) 09:54:41.209 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 48 └─[WakeUpCCIntervalGet] 09:54:41.210 SERIAL « [ACK] (0x06) 09:54:41.217 SERIAL « 0x0104011301e8 (6 bytes) 09:54:41.217 SERIAL » [ACK] (0x06) 09:54:41.217 DRIVER « [RES] [SendData] was sent: true 09:54:41.270 SERIAL « 0x0107001330000006dd (9 bytes) 09:54:41.271 SERIAL » [ACK] (0x06) 09:54:41.271 DRIVER « [REQ] [SendData] callback id: 48 transmit status: OK 09:54:41.321 SERIAL « 0x010c0004001506840600038401e0 (14 bytes) 09:54:41.322 CNTRLR [Node 021] [~] [Wake Up] wakeUpInterval: 900 => 900 [Endpoint 0] 09:54:41.323 CNTRLR [Node 021] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 09:54:41.323 SERIAL » [ACK] (0x06) 09:54:41.324 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 900 seconds controller node id: 1 09:54:41.325 CNTRLR « [Node 021] received wakeup configuration: wakeup interval: 900 seconds controller node: 1 09:54:41.326 CNTRLR [Node 021] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 09:54:41.326 CNTRLR [Node 021] AssociationCC: doing a partial interview... 09:54:41.326 CNTRLR [Node 021] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 09:54:41.327 CNTRLR [Node 021] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 09:54:41.327 CNTRLR [Node 021] BasicCC: doing a partial interview... 09:54:41.327 CNTRLR » [Node 021] querying Basic CC state... 09:54:41.331 SERIAL » 0x01090013150220022531c4 (11 bytes) 09:54:41.332 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 49 └─[BasicCCGet] 09:54:41.334 SERIAL « [ACK] (0x06) 09:54:41.339 SERIAL « 0x0104011301e8 (6 bytes) 09:54:41.340 SERIAL » [ACK] (0x06) 09:54:41.340 DRIVER « [RES] [SendData] was sent: true 09:54:41.448 SERIAL « 0x010700133100000cd6 (9 bytes) 09:54:41.448 SERIAL » [ACK] (0x06) 09:54:41.449 DRIVER « [REQ] [SendData] callback id: 49 transmit status: OK 09:54:41.509 SERIAL « 0x01090004001503200300c7 (11 bytes) 09:54:41.510 SERIAL » [ACK] (0x06) 09:54:41.512 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BasicCCReport] current value: 0 09:54:41.514 CNTRLR « [Node 021] received Basic CC state: current value: 0 09:54:41.514 CNTRLR [Node 021] [~] [Basic] interviewComplete: true => true [Endpoint 0] [internal] 09:54:41.514 CNTRLR [Node 021] BinarySensorCC: doing a partial interview... 09:54:41.514 CNTRLR » [Node 021] querying current value... 09:54:41.519 SERIAL » 0x01090013150230022532d7 (11 bytes) 09:54:41.519 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 50 └─[BinarySensorCCGet] type: Any 09:54:41.520 SERIAL « [ACK] (0x06) 09:54:41.527 SERIAL « 0x0104011301e8 (6 bytes) 09:54:41.527 SERIAL » [ACK] (0x06) 09:54:41.528 DRIVER « [RES] [SendData] was sent: true 09:54:41.621 SERIAL « 0x010700133200000ad3 (9 bytes) 09:54:41.621 SERIAL » [ACK] (0x06) 09:54:41.621 DRIVER « [REQ] [SendData] callback id: 50 transmit status: OK 09:54:41.667 SERIAL « 0x01090004001503300300d7 (11 bytes) 09:54:41.668 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:54:41.668 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:54:41.669 SERIAL » [ACK] (0x06) 09:54:41.670 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:54:41.671 CNTRLR « [Node 021] received current value: false 09:54:41.671 CNTRLR [Node 021] [~] [Binary Sensor] interviewComplete: true [Endpoint 0] [internal] => true 09:54:41.672 CNTRLR [Node 021] MultilevelSensorCC: doing a partial interview... 09:54:41.672 CNTRLR » [Node 021] querying Air temperature sensor reading... 09:54:41.676 SERIAL » 0x010b00131504310401002533d4 (13 bytes) 09:54:41.676 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 51 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 09:54:41.678 SERIAL « [ACK] (0x06) 09:54:41.684 SERIAL « 0x0104011301e8 (6 bytes) 09:54:41.685 SERIAL » [ACK] (0x06) 09:54:41.685 DRIVER « [RES] [SendData] was sent: true 09:54:41.800 SERIAL « 0x010700133300000cd4 (9 bytes) 09:54:41.800 SERIAL » [ACK] (0x06) 09:54:41.800 DRIVER « [REQ] [SendData] callback id: 51 transmit status: OK 09:54:41.850 SERIAL « 0x010c00040015063105012200bb48 (14 bytes) 09:54:41.850 CNTRLR [Node 021] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 09:54:41.851 CNTRLR [Node 021] [~] [Multilevel Sensor] Air temperature: 17.3 => 18.7 [Endpoint 0] 09:54:41.851 SERIAL » [ACK] (0x06) 09:54:41.852 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.7 09:54:41.854 CNTRLR « [Node 021] received current Air temperature sensor reading: 18.7 °C 09:54:41.854 CNTRLR » [Node 021] querying Illuminance sensor reading... 09:54:41.860 SERIAL » 0x010b00131504310403082534d9 (13 bytes) 09:54:41.860 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 52 └─[MultilevelSensorCCGet] sensor type: Illuminance scale: Lux 09:54:41.862 SERIAL « [ACK] (0x06) 09:54:41.869 SERIAL « 0x0104011301e8 (6 bytes) 09:54:41.869 SERIAL » [ACK] (0x06) 09:54:41.869 DRIVER « [RES] [SendData] was sent: true 09:54:41.979 SERIAL « 0x010700133400000cd3 (9 bytes) 09:54:41.980 SERIAL » [ACK] (0x06) 09:54:41.981 DRIVER « [REQ] [SendData] callback id: 52 transmit status: OK 09:54:42.030 SERIAL « 0x010c00040015063105030a0012cb (14 bytes) 09:54:42.031 CNTRLR [Node 021] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 09:54:42.032 CNTRLR [Node 021] [~] [Multilevel Sensor] Illuminance: 0 => 18 [Endpoint 0] 09:54:42.032 SERIAL » [ACK] (0x06) 09:54:42.034 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 18 09:54:42.036 CNTRLR « [Node 021] received current Illuminance sensor reading: 18 Lux 09:54:42.037 CNTRLR [Node 021] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 09:54:42.106 CNTRLR [Node 021] ConfigurationCC: Loading configuration parameters from device confi g 09:54:42.119 CNTRLR [Node 021] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 09:54:42.120 CNTRLR [Node 021] [Configuration] 1: metadata updated 09:54:42.122 CNTRLR [Node 021] [Configuration] 2: metadata updated 09:54:42.124 CNTRLR [Node 021] [Configuration] 3: metadata updated 09:54:42.125 CNTRLR [Node 021] [Configuration] 4: metadata updated 09:54:42.127 CNTRLR [Node 021] [Configuration] 6: metadata updated 09:54:42.129 CNTRLR [Node 021] [Configuration] 8: metadata updated 09:54:42.130 CNTRLR [Node 021] [Configuration] 9: metadata updated 09:54:42.132 CNTRLR [Node 021] [Configuration] 12: metadata updated 09:54:42.134 CNTRLR [Node 021] [Configuration] 14: metadata updated 09:54:42.135 CNTRLR [Node 021] [Configuration] 16: metadata updated 09:54:42.136 CNTRLR [Node 021] [Configuration] 20: metadata updated 09:54:42.137 CNTRLR [Node 021] [Configuration] 22: metadata updated 09:54:42.138 CNTRLR [Node 021] [Configuration] 24: metadata updated 09:54:42.139 CNTRLR [Node 021] [Configuration] 26: metadata updated 09:54:42.140 CNTRLR [Node 021] [Configuration] 40: metadata updated 09:54:42.141 CNTRLR [Node 021] [Configuration] 42: metadata updated 09:54:42.142 CNTRLR [Node 021] [Configuration] 60: metadata updated 09:54:42.143 CNTRLR [Node 021] [Configuration] 62: metadata updated 09:54:42.144 CNTRLR [Node 021] [Configuration] 64: metadata updated 09:54:42.145 CNTRLR [Node 021] [Configuration] 66: metadata updated 09:54:42.146 CNTRLR [Node 021] [Configuration] 80: metadata updated 09:54:42.147 CNTRLR [Node 021] [Configuration] 81: metadata updated 09:54:42.148 CNTRLR [Node 021] [Configuration] 82: metadata updated 09:54:42.149 CNTRLR [Node 021] [Configuration] 83: metadata updated 09:54:42.150 CNTRLR [Node 021] [Configuration] 86: metadata updated 09:54:42.151 CNTRLR [Node 021] [Configuration] 87: metadata updated 09:54:42.152 CNTRLR [Node 021] [Configuration] 89: metadata updated 09:54:42.153 CNTRLR [Node 021] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 09:54:42.153 CNTRLR » [Node 021] querying parameter #1 value... 09:54:42.160 SERIAL » 0x010a00131503700501253594 (12 bytes) 09:54:42.160 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 53 └─[ConfigurationCCGet] parameter #: 1 09:54:42.168 SERIAL « [ACK] (0x06) 09:54:42.188 SERIAL « 0x0104011301e8 (6 bytes) 09:54:42.189 SERIAL » [ACK] (0x06) 09:54:42.200 DRIVER « [RES] [SendData] was sent: true 09:54:42.223 SERIAL « 0x0107001335000006d8 (9 bytes) 09:54:42.223 SERIAL » [ACK] (0x06) 09:54:42.224 DRIVER « [REQ] [SendData] callback id: 53 transmit status: OK 09:54:42.273 SERIAL « 0x010b0004001505700601010a9c (13 bytes) 09:54:42.278 CNTRLR [Node 021] [~] [Configuration] 1: 10 => 10 09:54:42.279 SERIAL » [ACK] (0x06) 09:54:42.280 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 10 09:54:42.281 CNTRLR « [Node 021] parameter #1 has value: 10 09:54:42.281 CNTRLR » [Node 021] querying parameter #2 value... 09:54:42.285 SERIAL » 0x010a00131503700502253694 (12 bytes) 09:54:42.285 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 54 └─[ConfigurationCCGet] parameter #: 2 09:54:42.287 SERIAL « [ACK] (0x06) 09:54:42.294 SERIAL « 0x0104011301e8 (6 bytes) 09:54:42.294 SERIAL » [ACK] (0x06) 09:54:42.294 DRIVER « [RES] [SendData] was sent: true 09:54:42.399 SERIAL « 0x010700133600000bd6 (9 bytes) 09:54:42.399 SERIAL » [ACK] (0x06) 09:54:42.400 DRIVER « [REQ] [SendData] callback id: 54 transmit status: OK 09:54:42.449 SERIAL « 0x010b0004001505700602010f9a (13 bytes) 09:54:42.454 CNTRLR [Node 021] [~] [Configuration] 2: 15 => 15 09:54:42.455 SERIAL » [ACK] (0x06) 09:54:42.455 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 15 09:54:42.457 CNTRLR « [Node 021] parameter #2 has value: 15 09:54:42.457 CNTRLR » [Node 021] querying parameter #3 value... 09:54:42.461 SERIAL » 0x010a00131503700503253794 (12 bytes) 09:54:42.461 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 55 └─[ConfigurationCCGet] parameter #: 3 09:54:42.464 SERIAL « [ACK] (0x06) 09:54:42.470 SERIAL « 0x0104011301e8 (6 bytes) 09:54:42.471 SERIAL » [ACK] (0x06) 09:54:42.471 DRIVER « [RES] [SendData] was sent: true 09:54:42.569 SERIAL « 0x010700133700000bd7 (9 bytes) 09:54:42.569 SERIAL » [ACK] (0x06) 09:54:42.569 DRIVER « [REQ] [SendData] callback id: 55 transmit status: OK 09:54:42.619 SERIAL « 0x010b0004001505700603010195 (13 bytes) 09:54:42.624 CNTRLR [Node 021] [~] [Configuration] 3: 1 => 1 09:54:42.625 SERIAL » [ACK] (0x06) 09:54:42.626 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 1 09:54:42.629 CNTRLR « [Node 021] parameter #3 has value: 1 09:54:42.630 CNTRLR » [Node 021] querying parameter #4 value... 09:54:42.633 SERIAL » 0x010a0013150370050425389c (12 bytes) 09:54:42.634 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 56 └─[ConfigurationCCGet] parameter #: 4 09:54:42.635 SERIAL « [ACK] (0x06) 09:54:42.641 SERIAL « 0x0104011301e8 (6 bytes) 09:54:42.642 SERIAL » [ACK] (0x06) 09:54:42.642 DRIVER « [RES] [SendData] was sent: true 09:54:42.739 SERIAL « 0x010700133800000ad9 (9 bytes) 09:54:42.739 SERIAL » [ACK] (0x06) 09:54:42.739 DRIVER « [REQ] [SendData] callback id: 56 transmit status: OK 09:54:42.789 SERIAL « 0x010b0004001505700604010291 (13 bytes) 09:54:42.794 CNTRLR [Node 021] [~] [Configuration] 4: 2 => 2 09:54:42.795 SERIAL » [ACK] (0x06) 09:54:42.795 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 1 value: 2 09:54:42.797 CNTRLR « [Node 021] parameter #4 has value: 2 09:54:42.797 CNTRLR » [Node 021] querying parameter #6 value... 09:54:42.801 SERIAL » 0x010a0013150370050625399f (12 bytes) 09:54:42.801 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 57 └─[ConfigurationCCGet] parameter #: 6 09:54:42.803 SERIAL « [ACK] (0x06) 09:54:42.810 SERIAL « 0x0104011301e8 (6 bytes) 09:54:42.810 SERIAL » [ACK] (0x06) 09:54:42.811 DRIVER « [RES] [SendData] was sent: true 09:54:42.909 SERIAL « 0x010700133900000bd9 (9 bytes) 09:54:42.909 SERIAL » [ACK] (0x06) 09:54:42.911 DRIVER « [REQ] [SendData] callback id: 57 transmit status: OK 09:54:42.960 SERIAL « 0x010c000400150670060602001e88 (14 bytes) 09:54:42.968 CNTRLR [Node 021] [~] [Configuration] 6: 30 => 30 09:54:42.970 SERIAL » [ACK] (0x06) 09:54:42.971 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 2 value: 30 09:54:42.973 CNTRLR « [Node 021] parameter #6 has value: 30 09:54:42.973 CNTRLR » [Node 021] querying parameter #8 value... 09:54:42.979 SERIAL » 0x010a00131503700508253a92 (12 bytes) 09:54:42.979 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 58 └─[ConfigurationCCGet] parameter #: 8 09:54:42.981 SERIAL « [ACK] (0x06) 09:54:42.989 SERIAL « 0x0104011301e8 (6 bytes) 09:54:42.990 SERIAL » [ACK] (0x06) 09:54:42.992 DRIVER « [RES] [SendData] was sent: true 09:54:43.079 SERIAL « 0x010700133a00000adb (9 bytes) 09:54:43.083 SERIAL » [ACK] (0x06) 09:54:43.084 DRIVER « [REQ] [SendData] callback id: 58 transmit status: OK 09:54:43.129 SERIAL « 0x010b000400150570060801009f (13 bytes) 09:54:43.136 CNTRLR [Node 021] [~] [Configuration] 8: 0 => 0 09:54:43.137 SERIAL » [ACK] (0x06) 09:54:43.138 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 0 09:54:43.140 CNTRLR « [Node 021] parameter #8 has value: 0 09:54:43.140 CNTRLR » [Node 021] querying parameter #9 value... 09:54:43.146 SERIAL » 0x010a00131503700509253b92 (12 bytes) 09:54:43.147 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 59 └─[ConfigurationCCGet] parameter #: 9 09:54:43.150 SERIAL « [ACK] (0x06) 09:54:43.157 SERIAL « 0x0104011301e8 (6 bytes) 09:54:43.157 SERIAL » [ACK] (0x06) 09:54:43.158 DRIVER « [RES] [SendData] was sent: true 09:54:43.249 SERIAL « 0x010700133b00000ada (9 bytes) 09:54:43.250 SERIAL » [ACK] (0x06) 09:54:43.250 DRIVER « [REQ] [SendData] callback id: 59 transmit status: OK 09:54:43.300 SERIAL « 0x010c0004001506700609020028b1 (14 bytes) 09:54:43.310 CNTRLR [Node 021] [~] [Configuration] 9: 40 => 40 09:54:43.311 SERIAL » [ACK] (0x06) 09:54:43.312 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 2 value: 40 09:54:43.314 CNTRLR « [Node 021] parameter #9 has value: 40 09:54:43.315 CNTRLR » [Node 021] querying parameter #12 value... 09:54:43.338 SERIAL » 0x010a0013150370050c253c90 (12 bytes) 09:54:43.338 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 60 └─[ConfigurationCCGet] parameter #: 12 09:54:43.342 SERIAL « [ACK] (0x06) 09:54:43.347 SERIAL « 0x0104011301e8 (6 bytes) 09:54:43.348 SERIAL » [ACK] (0x06) 09:54:43.349 DRIVER « [RES] [SendData] was sent: true 09:54:43.420 SERIAL « 0x010700133c000008df (9 bytes) 09:54:43.420 SERIAL » [ACK] (0x06) 09:54:43.420 DRIVER « [REQ] [SendData] callback id: 60 transmit status: OK 09:54:43.469 SERIAL « 0x010b000400150570060c01009b (13 bytes) 09:54:43.474 CNTRLR [Node 021] [~] [Configuration] 12: 0 => 0 09:54:43.475 SERIAL » [ACK] (0x06) 09:54:43.476 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 1 value: 0 09:54:43.478 CNTRLR « [Node 021] parameter #12 has value: 0 09:54:43.478 CNTRLR » [Node 021] querying parameter #14 value... 09:54:43.501 SERIAL » 0x010a0013150370050e253d93 (12 bytes) 09:54:43.501 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 61 └─[ConfigurationCCGet] parameter #: 14 09:54:43.506 SERIAL « [ACK] (0x06) 09:54:43.511 SERIAL « 0x0104011301e8 (6 bytes) 09:54:43.511 SERIAL » [ACK] (0x06) 09:54:43.512 DRIVER « [RES] [SendData] was sent: true 09:54:43.589 SERIAL « 0x010700133d000009df (9 bytes) 09:54:43.590 SERIAL » [ACK] (0x06) 09:54:43.590 DRIVER « [REQ] [SendData] callback id: 61 transmit status: OK 09:54:43.639 SERIAL « 0x010b000400150570060e01ff66 (13 bytes) 09:54:43.644 CNTRLR [Node 021] [~] [Configuration] 14: 255 => 255 09:54:43.645 SERIAL » [ACK] (0x06) 09:54:43.646 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 255 09:54:43.647 CNTRLR « [Node 021] parameter #14 has value: 255 09:54:43.647 CNTRLR » [Node 021] querying parameter #16 value... 09:54:43.651 SERIAL » 0x010a00131503700510253e8e (12 bytes) 09:54:43.651 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 62 └─[ConfigurationCCGet] parameter #: 16 09:54:43.653 SERIAL « [ACK] (0x06) 09:54:43.660 SERIAL « 0x0104011301e8 (6 bytes) 09:54:43.660 SERIAL » [ACK] (0x06) 09:54:43.661 DRIVER « [RES] [SendData] was sent: true 09:54:43.759 SERIAL « 0x010700133e00000bde (9 bytes) 09:54:43.759 SERIAL » [ACK] (0x06) 09:54:43.759 DRIVER « [REQ] [SendData] callback id: 62 transmit status: OK 09:54:43.809 SERIAL « 0x010b0004001505700610010087 (13 bytes) 09:54:43.814 CNTRLR [Node 021] [~] [Configuration] 16: 0 => 0 09:54:43.815 SERIAL » [ACK] (0x06) 09:54:43.815 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 0 09:54:43.817 CNTRLR « [Node 021] parameter #16 has value: 0 09:54:43.817 CNTRLR » [Node 021] querying parameter #20 value... 09:54:43.820 SERIAL » 0x010a00131503700514253f8b (12 bytes) 09:54:43.821 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 63 └─[ConfigurationCCGet] parameter #: 20 09:54:43.823 SERIAL « [ACK] (0x06) 09:54:43.830 SERIAL « 0x0104011301e8 (6 bytes) 09:54:43.830 SERIAL » [ACK] (0x06) 09:54:43.830 DRIVER « [RES] [SendData] was sent: true 09:54:43.929 SERIAL « 0x010700133f00000bdf (9 bytes) 09:54:43.929 SERIAL » [ACK] (0x06) 09:54:43.934 DRIVER « [REQ] [SendData] callback id: 63 transmit status: OK 09:54:43.979 SERIAL « 0x010b0004001505700614010f8c (13 bytes) 09:54:43.984 CNTRLR [Node 021] [~] [Configuration] 20: 15 => 15 09:54:43.985 SERIAL » [ACK] (0x06) 09:54:43.986 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 15 09:54:43.987 CNTRLR « [Node 021] parameter #20 has value: 15 09:54:43.987 CNTRLR » [Node 021] querying parameter #22 value... 09:54:43.991 SERIAL » 0x010a001315037005162540f6 (12 bytes) 09:54:43.991 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 64 └─[ConfigurationCCGet] parameter #: 22 09:54:43.993 SERIAL « [ACK] (0x06) 09:54:44.000 SERIAL « 0x0104011301e8 (6 bytes) 09:54:44.000 SERIAL » [ACK] (0x06) 09:54:44.000 DRIVER « [RES] [SendData] was sent: true 09:54:44.099 SERIAL « 0x010700134000000ba0 (9 bytes) 09:54:44.100 SERIAL » [ACK] (0x06) 09:54:44.100 DRIVER « [REQ] [SendData] callback id: 64 transmit status: OK 09:54:44.150 SERIAL « 0x010c000400150670061602001e98 (14 bytes) 09:54:44.159 CNTRLR [Node 021] [~] [Configuration] 22: 30 => 30 09:54:44.161 SERIAL » [ACK] (0x06) 09:54:44.162 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 30 09:54:44.164 CNTRLR « [Node 021] parameter #22 has value: 30 09:54:44.164 CNTRLR » [Node 021] querying parameter #24 value... 09:54:44.170 SERIAL » 0x010a001315037005182541f9 (12 bytes) 09:54:44.171 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 65 └─[ConfigurationCCGet] parameter #: 24 09:54:44.173 SERIAL « [ACK] (0x06) 09:54:44.181 SERIAL « 0x0104011301e8 (6 bytes) 09:54:44.181 SERIAL » [ACK] (0x06) 09:54:44.182 DRIVER « [RES] [SendData] was sent: true 09:54:44.269 SERIAL « 0x010700134100000aa0 (9 bytes) 09:54:44.269 SERIAL » [ACK] (0x06) 09:54:44.270 DRIVER « [REQ] [SendData] callback id: 65 transmit status: OK 09:54:44.319 SERIAL « 0x010b000400150570061801008f (13 bytes) 09:54:44.329 CNTRLR [Node 021] [~] [Configuration] 24: 0 => 0 09:54:44.330 SERIAL » [ACK] (0x06) 09:54:44.331 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 24 value size: 1 value: 0 09:54:44.333 CNTRLR « [Node 021] parameter #24 has value: 0 09:54:44.333 CNTRLR » [Node 021] querying parameter #26 value... 09:54:44.344 SERIAL » 0x010a0013150370051a2542f8 (12 bytes) 09:54:44.345 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 66 └─[ConfigurationCCGet] parameter #: 26 09:54:44.347 SERIAL « [ACK] (0x06) 09:54:44.354 SERIAL « 0x0104011301e8 (6 bytes) 09:54:44.355 SERIAL » [ACK] (0x06) 09:54:44.356 DRIVER « [RES] [SendData] was sent: true 09:54:44.439 SERIAL « 0x0107001342000009a0 (9 bytes) 09:54:44.439 SERIAL » [ACK] (0x06) 09:54:44.439 DRIVER « [REQ] [SendData] callback id: 66 transmit status: OK 09:54:44.489 SERIAL « 0x010b000400150570061a01008d (13 bytes) 09:54:44.501 CNTRLR [Node 021] [~] [Configuration] 26: 0 => 0 09:54:44.503 SERIAL » [ACK] (0x06) 09:54:44.504 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 26 value size: 1 value: 0 09:54:44.506 CNTRLR « [Node 021] parameter #26 has value: 0 09:54:44.507 CNTRLR » [Node 021] querying parameter #40 value... 09:54:44.514 SERIAL » 0x010a001315037005282543cb (12 bytes) 09:54:44.515 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 67 └─[ConfigurationCCGet] parameter #: 40 09:54:44.518 SERIAL « [ACK] (0x06) 09:54:44.524 SERIAL « 0x0104011301e8 (6 bytes) 09:54:44.525 SERIAL » [ACK] (0x06) 09:54:44.526 DRIVER « [RES] [SendData] was sent: true 09:54:44.609 SERIAL « 0x0107001343000009a1 (9 bytes) 09:54:44.609 SERIAL » [ACK] (0x06) 09:54:44.610 DRIVER « [REQ] [SendData] callback id: 67 transmit status: OK 09:54:44.660 SERIAL « 0x010c00040015067006280200c870 (14 bytes) 09:54:44.667 CNTRLR [Node 021] [~] [Configuration] 40: 200 => 200 09:54:44.668 SERIAL » [ACK] (0x06) 09:54:44.669 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 2 value: 200 09:54:44.670 CNTRLR « [Node 021] parameter #40 has value: 200 09:54:44.671 CNTRLR » [Node 021] querying parameter #42 value... 09:54:44.684 SERIAL » 0x010a0013150370052a2544ce (12 bytes) 09:54:44.685 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 68 └─[ConfigurationCCGet] parameter #: 42 09:54:44.687 SERIAL « [ACK] (0x06) 09:54:44.695 SERIAL « 0x0104011301e8 (6 bytes) 09:54:44.695 SERIAL » [ACK] (0x06) 09:54:44.696 DRIVER « [RES] [SendData] was sent: true 09:54:44.779 SERIAL « 0x0107001344000009a6 (9 bytes) 09:54:44.779 SERIAL » [ACK] (0x06) 09:54:44.780 DRIVER « [REQ] [SendData] callback id: 68 transmit status: OK 09:54:44.830 SERIAL « 0x010c000400150670062a020000ba (14 bytes) 09:54:44.840 CNTRLR [Node 021] [~] [Configuration] 42: 0 => 0 09:54:44.841 SERIAL » [ACK] (0x06) 09:54:44.845 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 0 09:54:44.847 CNTRLR « [Node 021] parameter #42 has value: 0 09:54:44.848 CNTRLR » [Node 021] querying parameter #60 value... 09:54:44.854 SERIAL » 0x010a0013150370053c2545d9 (12 bytes) 09:54:44.854 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 69 └─[ConfigurationCCGet] parameter #: 60 09:54:44.857 SERIAL « [ACK] (0x06) 09:54:44.864 SERIAL « 0x0104011301e8 (6 bytes) 09:54:44.864 SERIAL » [ACK] (0x06) 09:54:44.865 DRIVER « [RES] [SendData] was sent: true 09:54:44.948 SERIAL « 0x0107001345000009a7 (9 bytes) 09:54:44.949 SERIAL » [ACK] (0x06) 09:54:44.949 DRIVER « [REQ] [SendData] callback id: 69 transmit status: OK 09:54:44.997 SERIAL « 0x010b000400150570063c010aa1 (13 bytes) 09:54:45.009 CNTRLR [Node 021] [~] [Configuration] 60: 10 => 10 09:54:45.011 SERIAL » [ACK] (0x06) 09:54:45.012 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 1 value: 10 09:54:45.015 CNTRLR « [Node 021] parameter #60 has value: 10 09:54:45.016 CNTRLR » [Node 021] querying parameter #62 value... 09:54:45.024 SERIAL » 0x010a0013150370053e2546d8 (12 bytes) 09:54:45.024 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 70 └─[ConfigurationCCGet] parameter #: 62 09:54:45.027 SERIAL « [ACK] (0x06) 09:54:45.034 SERIAL « 0x0104011301e8 (6 bytes) 09:54:45.034 SERIAL » [ACK] (0x06) 09:54:45.035 DRIVER « [RES] [SendData] was sent: true 09:54:45.119 SERIAL « 0x0107001346000009a4 (9 bytes) 09:54:45.119 SERIAL » [ACK] (0x06) 09:54:45.120 DRIVER « [REQ] [SendData] callback id: 70 transmit status: OK 09:54:45.170 SERIAL « 0x010c000400150670063e02038429 (14 bytes) 09:54:45.177 CNTRLR [Node 021] [~] [Configuration] 62: 900 => 900 09:54:45.178 SERIAL » [ACK] (0x06) 09:54:45.179 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 62 value size: 2 value: 900 09:54:45.181 CNTRLR « [Node 021] parameter #62 has value: 900 09:54:45.181 CNTRLR » [Node 021] querying parameter #64 value... 09:54:45.186 SERIAL » 0x010a001315037005402547a7 (12 bytes) 09:54:45.186 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 71 └─[ConfigurationCCGet] parameter #: 64 09:54:45.188 SERIAL « [ACK] (0x06) 09:54:45.196 SERIAL « 0x0104011301e8 (6 bytes) 09:54:45.196 SERIAL » [ACK] (0x06) 09:54:45.197 DRIVER « [RES] [SendData] was sent: true 09:54:45.289 SERIAL « 0x010700134700000aa6 (9 bytes) 09:54:45.289 SERIAL » [ACK] (0x06) 09:54:45.290 DRIVER « [REQ] [SendData] callback id: 71 transmit status: OK 09:54:45.340 SERIAL « 0x010c0004001506700640020000d0 (14 bytes) 09:54:45.349 CNTRLR [Node 021] [~] [Configuration] 64: 0 => 0 09:54:45.351 SERIAL » [ACK] (0x06) 09:54:45.352 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 64 value size: 2 value: 0 09:54:45.354 CNTRLR « [Node 021] parameter #64 has value: 0 09:54:45.354 CNTRLR » [Node 021] querying parameter #66 value... 09:54:45.367 SERIAL » 0x010a001315037005422548aa (12 bytes) 09:54:45.368 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 72 └─[ConfigurationCCGet] parameter #: 66 09:54:45.370 SERIAL « [ACK] (0x06) 09:54:45.377 SERIAL « 0x0104011301e8 (6 bytes) 09:54:45.377 SERIAL » [ACK] (0x06) 09:54:45.378 DRIVER « [RES] [SendData] was sent: true 09:54:45.459 SERIAL « 0x0107001348000009aa (9 bytes) 09:54:45.459 SERIAL » [ACK] (0x06) 09:54:45.459 DRIVER « [REQ] [SendData] callback id: 72 transmit status: OK 09:54:45.510 SERIAL « 0x010c0004001506700642020000d2 (14 bytes) 09:54:45.515 CNTRLR [Node 021] [~] [Configuration] 66: 0 => 0 09:54:45.516 SERIAL » [ACK] (0x06) 09:54:45.516 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 66 value size: 2 value: 0 09:54:45.517 CNTRLR « [Node 021] parameter #66 has value: 0 09:54:45.518 CNTRLR » [Node 021] querying parameter #80 value... 09:54:45.521 SERIAL » 0x010a001315037005502549b9 (12 bytes) 09:54:45.522 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 73 └─[ConfigurationCCGet] parameter #: 80 09:54:45.523 SERIAL « [ACK] (0x06) 09:54:45.531 SERIAL « 0x0104011301e8 (6 bytes) 09:54:45.531 SERIAL » [ACK] (0x06) 09:54:45.531 DRIVER « [RES] [SendData] was sent: true 09:54:45.629 SERIAL « 0x010700134900000aa8 (9 bytes) 09:54:45.629 SERIAL » [ACK] (0x06) 09:54:45.630 DRIVER « [REQ] [SendData] callback id: 73 transmit status: OK 09:54:45.679 SERIAL « 0x010b00040015057006500100c7 (13 bytes) 09:54:45.684 CNTRLR [Node 021] [~] [Configuration] 80: 0 => 0 09:54:45.685 SERIAL » [ACK] (0x06) 09:54:45.686 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 80 value size: 1 value: 0 09:54:45.687 CNTRLR « [Node 021] parameter #80 has value: 0 09:54:45.687 CNTRLR » [Node 021] querying parameter #81 value... 09:54:45.693 SERIAL » 0x010a00131503700551254abb (12 bytes) 09:54:45.693 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 74 └─[ConfigurationCCGet] parameter #: 81 09:54:45.695 SERIAL « [ACK] (0x06) 09:54:45.701 SERIAL « 0x0104011301e8 (6 bytes) 09:54:45.702 SERIAL » [ACK] (0x06) 09:54:45.702 DRIVER « [RES] [SendData] was sent: true 09:54:45.799 SERIAL « 0x010700134a00000aab (9 bytes) 09:54:45.799 SERIAL » [ACK] (0x06) 09:54:45.799 DRIVER « [REQ] [SendData] callback id: 74 transmit status: OK 09:54:45.849 SERIAL « 0x010b00040015057006510132f4 (13 bytes) 09:54:45.854 CNTRLR [Node 021] [~] [Configuration] 81: 50 => 50 09:54:45.855 SERIAL » [ACK] (0x06) 09:54:45.856 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 81 value size: 1 value: 50 09:54:45.857 CNTRLR « [Node 021] parameter #81 has value: 50 09:54:45.857 CNTRLR » [Node 021] querying parameter #82 value... 09:54:45.861 SERIAL » 0x010a00131503700552254bb9 (12 bytes) 09:54:45.861 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 75 └─[ConfigurationCCGet] parameter #: 82 09:54:45.863 SERIAL « [ACK] (0x06) 09:54:45.870 SERIAL « 0x0104011301e8 (6 bytes) 09:54:45.871 SERIAL » [ACK] (0x06) 09:54:45.871 DRIVER « [RES] [SendData] was sent: true 09:54:45.968 SERIAL « 0x010700134b00000aaa (9 bytes) 09:54:45.969 SERIAL » [ACK] (0x06) 09:54:45.969 DRIVER « [REQ] [SendData] callback id: 75 transmit status: OK 09:54:46.018 SERIAL « 0x010c0004001506700652020064a6 (14 bytes) 09:54:46.023 CNTRLR [Node 021] [~] [Configuration] 82: 100 => 100 09:54:46.023 SERIAL » [ACK] (0x06) 09:54:46.024 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 82 value size: 2 value: 100 09:54:46.025 CNTRLR « [Node 021] parameter #82 has value: 100 09:54:46.026 CNTRLR » [Node 021] querying parameter #83 value... 09:54:46.031 SERIAL » 0x010a00131503700553254cbf (12 bytes) 09:54:46.031 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 76 └─[ConfigurationCCGet] parameter #: 83 09:54:46.033 SERIAL « [ACK] (0x06) 09:54:46.040 SERIAL « 0x0104011301e8 (6 bytes) 09:54:46.040 SERIAL » [ACK] (0x06) 09:54:46.041 DRIVER « [RES] [SendData] was sent: true 09:54:46.139 SERIAL « 0x010700134c00000bac (9 bytes) 09:54:46.139 SERIAL » [ACK] (0x06) 09:54:46.140 DRIVER « [REQ] [SendData] callback id: 76 transmit status: OK 09:54:46.190 SERIAL « 0x010c00040015067006530203e828 (14 bytes) 09:54:46.200 CNTRLR [Node 021] [~] [Configuration] 83: 1000 => 1000 09:54:46.201 SERIAL » [ACK] (0x06) 09:54:46.202 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 83 value size: 2 value: 1000 09:54:46.204 CNTRLR « [Node 021] parameter #83 has value: 1000 09:54:46.205 CNTRLR » [Node 021] querying parameter #86 value... 09:54:46.211 SERIAL » 0x010a00131503700556254dbb (12 bytes) 09:54:46.212 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 77 └─[ConfigurationCCGet] parameter #: 86 09:54:46.215 SERIAL « [ACK] (0x06) 09:54:46.223 SERIAL « 0x0104011301e8 (6 bytes) 09:54:46.223 SERIAL » [ACK] (0x06) 09:54:46.225 DRIVER « [RES] [SendData] was sent: true 09:54:46.309 SERIAL « 0x010700134d00000aac (9 bytes) 09:54:46.309 SERIAL » [ACK] (0x06) 09:54:46.310 DRIVER « [REQ] [SendData] callback id: 77 transmit status: OK 09:54:46.359 SERIAL « 0x010b00040015057006560112d3 (13 bytes) 09:54:46.369 CNTRLR [Node 021] [~] [Configuration] 86: 18 => 18 09:54:46.370 SERIAL » [ACK] (0x06) 09:54:46.371 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 86 value size: 1 value: 18 09:54:46.374 CNTRLR « [Node 021] parameter #86 has value: 18 09:54:46.374 CNTRLR » [Node 021] querying parameter #87 value... 09:54:46.381 SERIAL » 0x010a00131503700557254eb9 (12 bytes) 09:54:46.381 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 78 └─[ConfigurationCCGet] parameter #: 87 09:54:46.384 SERIAL « [ACK] (0x06) 09:54:46.391 SERIAL « 0x0104011301e8 (6 bytes) 09:54:46.392 SERIAL » [ACK] (0x06) 09:54:46.393 DRIVER « [RES] [SendData] was sent: true 09:54:46.412 SERIAL « 0x010c00040003063105042204a743 (14 bytes) 09:54:46.413 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:54:46.414 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 218.2 => 119.1 [Endpoint 0] 09:54:46.415 SERIAL » [ACK] (0x06) 09:54:46.416 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 119.1 09:54:46.488 SERIAL « 0x010700134e00000bae (9 bytes) 09:54:46.488 SERIAL » [ACK] (0x06) 09:54:46.489 DRIVER « [REQ] [SendData] callback id: 78 transmit status: OK 09:54:46.538 SERIAL « 0x010b0004001505700657011cdc (13 bytes) 09:54:46.547 CNTRLR [Node 021] [~] [Configuration] 87: 28 => 28 09:54:46.548 SERIAL » [ACK] (0x06) 09:54:46.550 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 87 value size: 1 value: 28 09:54:46.552 CNTRLR « [Node 021] parameter #87 has value: 28 09:54:46.552 CNTRLR » [Node 021] querying parameter #89 value... 09:54:46.559 SERIAL » 0x010a00131503700559254fb6 (12 bytes) 09:54:46.560 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 79 └─[ConfigurationCCGet] parameter #: 89 09:54:46.563 SERIAL « [ACK] (0x06) 09:54:46.570 SERIAL « 0x0104011301e8 (6 bytes) 09:54:46.571 SERIAL » [ACK] (0x06) 09:54:46.572 DRIVER « [RES] [SendData] was sent: true 09:54:46.659 SERIAL « 0x010700134f00000aae (9 bytes) 09:54:46.659 SERIAL » [ACK] (0x06) 09:54:46.660 DRIVER « [REQ] [SendData] callback id: 79 transmit status: OK 09:54:46.710 SERIAL « 0x010b00040015057006590101cf (13 bytes) 09:54:46.719 CNTRLR [Node 021] [~] [Configuration] 89: 1 => 1 09:54:46.720 SERIAL » [ACK] (0x06) 09:54:46.722 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 89 value size: 1 value: 1 09:54:46.724 CNTRLR « [Node 021] parameter #89 has value: 1 09:54:46.725 CNTRLR [Node 021] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 09:54:46.804 CNTRLR [Node 021] AlarmSensorCC: doing a partial interview... 09:54:46.805 CNTRLR » [Node 021] querying current value for General Purpose... 09:54:46.814 SERIAL » 0x010a001315039c0100255018 (12 bytes) 09:54:46.815 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 80 └─[AlarmSensorCCGet] sensor type: General Purpose 09:54:46.817 SERIAL « [ACK] (0x06) 09:54:46.823 SERIAL « 0x0104011301e8 (6 bytes) 09:54:46.823 SERIAL » [ACK] (0x06) 09:54:46.824 DRIVER « [RES] [SendData] was sent: true 09:54:46.878 SERIAL « 0x0107001350000006bd (9 bytes) 09:54:46.878 SERIAL » [ACK] (0x06) 09:54:46.878 DRIVER « [REQ] [SendData] callback id: 80 transmit status: OK 09:54:46.929 SERIAL « 0x010d00040015079c0215000000006f (15 bytes) 09:54:46.930 CNTRLR [Node 021] [~] [Alarm Sensor] state[0]: false => false [Endpoint 0] 09:54:46.931 CNTRLR [Node 021] [+] [Alarm Sensor] severity[0]: undefined [Endpoint 0] 09:54:46.931 CNTRLR [Node 021] [+] [Alarm Sensor] duration[0]: undefined [Endpoint 0] 09:54:46.932 SERIAL » [ACK] (0x06) 09:54:46.933 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: false 09:54:46.934 CNTRLR « [Node 021] received current value for General Purpose: state: false 09:54:46.934 CNTRLR [Node 021] [~] [Alarm Sensor] interviewComplete: true [Endpoint 0] [internal] => true 09:54:46.935 CNTRLR [Node 021] MultiChannelAssociationCC: doing a partial interview... 09:54:46.935 CNTRLR » [Node 021] querying multi channel association group #1... 09:54:46.939 SERIAL » 0x010a001315038e0201255109 (12 bytes) 09:54:46.939 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 81 └─[MultiChannelAssociationCCGet] group id: 1 09:54:46.941 SERIAL « [ACK] (0x06) 09:54:46.947 SERIAL « 0x0104011301e8 (6 bytes) 09:54:46.948 SERIAL » [ACK] (0x06) 09:54:46.948 DRIVER « [RES] [SendData] was sent: true 09:54:47.059 SERIAL « 0x010700135100000cb6 (9 bytes) 09:54:47.059 SERIAL » [ACK] (0x06) 09:54:47.060 DRIVER « [REQ] [SendData] callback id: 81 transmit status: OK 09:54:47.114 SERIAL « 0x010c00040015068e03010500016c (14 bytes) 09:54:47.114 SERIAL » [ACK] (0x06) 09:54:47.117 CNTRLR [Node 021] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 09:54:47.118 CNTRLR [Node 021] [~] [Multi Channel Association] nodeIds[1]: 1 => 1 09:54:47.120 CNTRLR [Node 021] [~] [Multi Channel Association] endpoints[1]: => 09:54:47.121 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: 1 endpoints: 09:54:47.122 CNTRLR « [Node 021] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 09:54:47.122 CNTRLR » [Node 021] querying multi channel association group #2... 09:54:47.126 SERIAL » 0x010a001315038e0202255209 (12 bytes) 09:54:47.126 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 82 └─[MultiChannelAssociationCCGet] group id: 2 09:54:47.132 SERIAL « [ACK] (0x06) 09:54:47.138 SERIAL « 0x0104011301e8 (6 bytes) 09:54:47.138 SERIAL » [ACK] (0x06) 09:54:47.140 DRIVER « [RES] [SendData] was sent: true 09:54:47.229 SERIAL « 0x010700135200000ab3 (9 bytes) 09:54:47.229 SERIAL » [ACK] (0x06) 09:54:47.230 DRIVER « [REQ] [SendData] callback id: 82 transmit status: OK 09:54:47.286 SERIAL « 0x010c00040015068e03020500016f (14 bytes) 09:54:47.286 SERIAL » [ACK] (0x06) 09:54:47.287 CNTRLR [Node 021] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 09:54:47.288 CNTRLR [Node 021] [~] [Multi Channel Association] nodeIds[2]: 1 => 1 09:54:47.289 CNTRLR [Node 021] [~] [Multi Channel Association] endpoints[2]: => 09:54:47.290 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: 1 endpoints: 09:54:47.292 CNTRLR « [Node 021] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 09:54:47.292 CNTRLR » [Node 021] querying additional non-multi-channel association groups... 09:54:47.292 CNTRLR » [Node 021] querying association group #3... 09:54:47.297 SERIAL » 0x010a00131503850203255302 (12 bytes) 09:54:47.297 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 83 └─[AssociationCCGet] group id: 3 09:54:47.312 SERIAL « [ACK] (0x06) 09:54:47.313 SERIAL « 0x0104011301e8 (6 bytes) 09:54:47.314 SERIAL » [ACK] (0x06) 09:54:47.314 DRIVER « [RES] [SendData] was sent: true 09:54:47.399 SERIAL « 0x010700135300000ab2 (9 bytes) 09:54:47.399 SERIAL » [ACK] (0x06) 09:54:47.399 DRIVER « [REQ] [SendData] callback id: 83 transmit status: OK 09:54:47.448 SERIAL « 0x010c000400150685030301000161 (14 bytes) 09:54:47.449 SERIAL » [ACK] (0x06) 09:54:47.450 CNTRLR [Node 021] [~] [Association] maxNodes[3]: 1 => 1 [internal] 09:54:47.450 CNTRLR [Node 021] [~] [Association] nodeIds[3]: 1 => 1 [internal] 09:54:47.450 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 09:54:47.451 CNTRLR « [Node 021] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 09:54:47.452 CNTRLR [Node 021] [~] [Association] hasLifeline: true => true [internal] 09:54:47.452 CNTRLR [Node 021] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 09:54:47.487 CNTRLR [Node 021] Interview stage completed: CommandClasses 09:54:47.488 CNTRLR [Node 021] Interview stage completed: OverwriteConfig 09:54:47.488 CNTRLR » [Node 021] requesting node neighbors... 09:54:47.492 SERIAL » 0x01070080150000006d (9 bytes) 09:54:47.492 DRIVER » [Node 021] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 09:54:47.494 SERIAL « [ACK] (0x06) 09:54:47.497 SERIAL « 0x0120018005f80c000000000000000000000000000000000000000000000000000 (34 bytes) 0af 09:54:47.497 SERIAL » [ACK] (0x06) 09:54:47.498 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 12, 13, 14, 15, 16, 19, 20 09:54:47.501 CNTRLR « [Node 021] node neighbors received: 1, 3, 12, 13, 14, 15, 16, 19, 20 09:54:47.501 CNTRLR [Node 021] Interview stage completed: Neighbors 09:54:47.501 CNTRLR [Node 021] Interview completed 09:54:47.570 SERIAL « 0x010c000400030631050422089971 (14 bytes) 09:54:47.570 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:54:47.571 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 119.1 => 220.1 [Endpoint 0] 09:54:47.572 SERIAL » [ACK] (0x06) 09:54:47.573 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 220.1 09:54:48.413 SERIAL « 0x010c00040003063105042204a743 (14 bytes) 09:54:48.414 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:54:48.415 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 220.1 => 119.1 [Endpoint 0] 09:54:48.416 SERIAL » [ACK] (0x06) 09:54:48.417 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 119.1 09:54:48.502 CNTRLR » [Node 021] Sending node back to sleep... 09:54:48.509 SERIAL » 0x010900131502840825540f (11 bytes) 09:54:48.509 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 84 └─[WakeUpCCNoMoreInformation] 09:54:48.511 SERIAL « [ACK] (0x06) 09:54:48.517 SERIAL « 0x0104011301e8 (6 bytes) 09:54:48.518 SERIAL » [ACK] (0x06) 09:54:48.519 DRIVER « [RES] [SendData] was sent: true 09:54:48.571 SERIAL « 0x0107001354000006b9 (9 bytes) 09:54:48.571 SERIAL » [ACK] (0x06) 09:54:48.572 DRIVER « [REQ] [SendData] callback id: 84 transmit status: OK 09:54:48.576 CNTRLR [Node 021] The node is now asleep. 09:54:48.578 CNTRLR [Node 021] Node asleep 09:54:49.095 SERIAL « 0x010c00040015063105012200bb48 (14 bytes) 09:54:49.096 CNTRLR [Node 021] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 09:54:49.097 CNTRLR [Node 021] [~] [Multilevel Sensor] Air temperature: 18.7 => 18.7 [Endpoint 0] 09:54:49.098 SERIAL » [ACK] (0x06) 09:54:49.100 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.7 09:54:51.414 SERIAL « 0x010c0004000306310504220a16fc (14 bytes) 09:54:51.415 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:54:51.416 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 119.1 => 258.2 [Endpoint 0] 09:54:51.417 SERIAL » [ACK] (0x06) 09:54:51.418 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 258.2 09:54:52.414 SERIAL « 0x010c00040003063105042207f116 (14 bytes) 09:54:52.415 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:54:52.416 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 258.2 => 203.3 [Endpoint 0] 09:54:52.416 SERIAL » [ACK] (0x06) 09:54:52.418 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 203.3 09:54:58.173 SERIAL » 0x010e00131f07600d00012501002555c2 (16 bytes) 09:54:58.175 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 85 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCSet] target value: false 09:54:58.177 SERIAL « [ACK] (0x06) 09:54:58.186 SERIAL « 0x0104011301e8 (6 bytes) 09:54:58.187 SERIAL » [ACK] (0x06) 09:54:58.191 DRIVER « [RES] [SendData] was sent: true 09:54:58.202 SERIAL « 0x0107001355000002bc (9 bytes) 09:54:58.202 SERIAL » [ACK] (0x06) 09:54:58.203 DRIVER « [REQ] [SendData] callback id: 85 transmit status: OK 09:54:58.215 SERIAL » 0x010d00131f06600d000125022556c0 (15 bytes) 09:54:58.215 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 86 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 09:54:58.218 SERIAL « [ACK] (0x06) 09:54:58.224 SERIAL « 0x0104011301e8 (6 bytes) 09:54:58.224 SERIAL » [ACK] (0x06) 09:54:58.225 DRIVER « [RES] [SendData] was sent: true 09:54:58.242 SERIAL « 0x0107001356000002bf (9 bytes) 09:54:58.242 SERIAL » [ACK] (0x06) 09:54:58.243 DRIVER « [REQ] [SendData] callback id: 86 transmit status: OK 09:54:58.253 SERIAL « 0x010d0004001f07600d0100250300a4 (15 bytes) 09:54:58.255 CNTRLR [Node 031] [~] [Binary Switch] currentValue: true => false [Endpoint 1] 09:54:58.255 SERIAL » [ACK] (0x06) 09:54:58.260 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: false 09:55:17.416 SERIAL « 0x010c0004000306310504220440a4 (14 bytes) 09:55:17.417 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:55:17.418 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 203.3 => 108.8 [Endpoint 0] 09:55:17.418 SERIAL » [ACK] (0x06) 09:55:17.419 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 108.8 09:55:21.417 SERIAL « 0x010c000400030631050422050ce9 (14 bytes) 09:55:21.418 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:55:21.419 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 108.8 => 129.2 [Endpoint 0] 09:55:21.420 SERIAL » [ACK] (0x06) 09:55:21.422 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 129.2 09:55:26.417 SERIAL « 0x010c00040003063105042203ed0e (14 bytes) 09:55:26.418 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:55:26.418 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 129.2 => 100.5 [Endpoint 0] 09:55:26.419 SERIAL » [ACK] (0x06) 09:55:26.420 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 100.5 09:55:30.416 SERIAL « 0x010c00040003063105042204c521 (14 bytes) 09:55:30.417 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:55:30.418 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 100.5 => 122.1 [Endpoint 0] 09:55:30.418 SERIAL » [ACK] (0x06) 09:55:30.420 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 122.1 09:55:53.420 SERIAL « 0x010c00040003063105042205a045 (14 bytes) 09:55:53.421 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:55:53.421 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 122.1 => 144 [Endpoint 0] 09:55:53.422 SERIAL » [ACK] (0x06) 09:55:53.422 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 144 09:55:55.405 SERIAL « 0x0110000400230a600d02003105012200c07a (18 bytes) 09:55:55.406 CNTRLR [Node 035] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:55:55.407 CNTRLR [Node 035] [~] [Multilevel Sensor] Air temperature: 18.9 => 19.2 [Endpoint 2] 09:55:55.408 SERIAL » [ACK] (0x06) 09:55:55.409 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 19.2 09:55:58.421 SERIAL « 0x010c00040003063105042204a347 (14 bytes) 09:55:58.422 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:55:58.422 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 144 => 118.7 [Endpoint 0] 09:55:58.423 SERIAL » [ACK] (0x06) 09:55:58.424 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 118.7 09:56:00.421 SERIAL « 0x010c00040003063105042205688d (14 bytes) 09:56:00.422 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:56:00.423 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 118.7 => 138.4 [Endpoint 0] 09:56:00.424 SERIAL » [ACK] (0x06) 09:56:00.425 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 138.4 09:56:05.748 SERIAL « 0x0114000400180e600d010032022144000001bf00007e (22 bytes) 09:56:05.751 CNTRLR [Node 024] [~] [Meter] value[65537]: 4.47 => 4.47 [Endpoint 1] 09:56:05.752 CNTRLR [Node 024] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 1] 09:56:05.753 SERIAL » [ACK] (0x06) 09:56:05.755 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 4.47 time delta: 0 seconds 09:56:05.822 SERIAL « 0x0114000400180e600d02003202214400006a8a000023 (22 bytes) 09:56:05.823 CNTRLR [Node 024] [~] [Meter] value[65537]: 272.68 => 272.74 [Endpoint 2] 09:56:05.824 CNTRLR [Node 024] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 2] 09:56:05.825 SERIAL » [ACK] (0x06) 09:56:05.827 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 272.74 time delta: 0 seconds 09:56:08.422 SERIAL « 0x010c000400030631050422048a6e (14 bytes) 09:56:08.423 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:56:08.424 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 138.4 => 116.2 [Endpoint 0] 09:56:08.424 SERIAL » [ACK] (0x06) 09:56:08.426 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 116.2 09:56:18.423 SERIAL « 0x010c000400030631050422056c89 (14 bytes) 09:56:18.424 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:56:18.425 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 116.2 => 138.8 [Endpoint 0] 09:56:18.426 SERIAL » [ACK] (0x06) 09:56:18.428 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 138.8 09:56:20.423 SERIAL « 0x010c000400030631050422048165 (14 bytes) 09:56:20.425 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:56:20.426 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 138.8 => 115.3 [Endpoint 0] 09:56:20.427 SERIAL » [ACK] (0x06) 09:56:20.428 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 115.3 09:56:21.423 SERIAL « 0x010c0004000306310504220908e1 (14 bytes) 09:56:21.424 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:56:21.425 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 115.3 => 231.2 [Endpoint 0] 09:56:21.426 SERIAL » [ACK] (0x06) 09:56:21.428 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 231.2 09:56:23.423 SERIAL « 0x010c00040003063105042204a246 (14 bytes) 09:56:23.424 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:56:23.424 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 231.2 => 118.6 [Endpoint 0] 09:56:23.425 SERIAL » [ACK] (0x06) 09:56:23.426 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 118.6 09:56:40.250 SERIAL « 0x01080004001102840763 (10 bytes) 09:56:40.250 SERIAL » [ACK] (0x06) 09:56:40.251 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:56:40.254 CNTRLR « [Node 017] received wakeup notification 09:56:40.255 CNTRLR [Node 017] The node is now awake. 09:56:41.257 CNTRLR » [Node 017] Sending node back to sleep... 09:56:41.262 SERIAL » 0x0109001311028408255708 (11 bytes) 09:56:41.262 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 87 └─[WakeUpCCNoMoreInformation] 09:56:41.263 SERIAL « [ACK] (0x06) 09:56:41.270 SERIAL « 0x0104011301e8 (6 bytes) 09:56:41.270 SERIAL » [ACK] (0x06) 09:56:41.270 DRIVER « [RES] [SendData] was sent: true 09:56:41.395 SERIAL « 0x010700135700000eb2 (9 bytes) 09:56:41.395 SERIAL » [ACK] (0x06) 09:56:41.396 DRIVER « [REQ] [SendData] callback id: 87 transmit status: OK 09:56:41.398 CNTRLR [Node 017] The node is now asleep. 09:56:41.399 CNTRLR [Node 017] Node asleep 09:56:43.425 SERIAL « 0x010c00040003063105042203ec0f (14 bytes) 09:56:43.426 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:56:43.427 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 118.6 => 100.4 [Endpoint 0] 09:56:43.427 SERIAL » [ACK] (0x06) 09:56:43.428 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 100.4 09:56:44.425 SERIAL « 0x010c00040003063105042204c420 (14 bytes) 09:56:44.427 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:56:44.428 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 100.4 => 122 [Endpoint 0] 09:56:44.429 SERIAL » [ACK] (0x06) 09:56:44.431 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 122 09:56:54.852 SERIAL « 0x01080004102002840742 (10 bytes) 09:56:54.853 SERIAL » [ACK] (0x06) 09:56:54.854 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:56:54.856 CNTRLR « [Node 032] received wakeup notification 09:56:54.857 CNTRLR [Node 032] The node is now awake. 09:56:54.900 SERIAL « 0x01080004102002840742 (10 bytes) 09:56:54.900 SERIAL » [ACK] (0x06) 09:56:54.901 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:56:54.904 CNTRLR « [Node 032] received wakeup notification 09:56:54.972 SERIAL « 0x01080004102002840742 (10 bytes) 09:56:54.973 SERIAL » [ACK] (0x06) 09:56:54.974 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:56:54.976 CNTRLR « [Node 032] received wakeup notification 09:56:55.066 SERIAL « 0x01080004102002840742 (10 bytes) 09:56:55.067 SERIAL » [ACK] (0x06) 09:56:55.067 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:56:55.069 CNTRLR « [Node 032] received wakeup notification 09:56:55.119 SERIAL « 0x01080004102002840742 (10 bytes) 09:56:55.120 SERIAL » [ACK] (0x06) 09:56:55.121 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:56:55.123 CNTRLR « [Node 032] received wakeup notification 09:56:55.190 SERIAL « 0x01080004102002840742 (10 bytes) 09:56:55.191 SERIAL » [ACK] (0x06) 09:56:55.192 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:56:55.193 CNTRLR « [Node 032] received wakeup notification 09:56:55.254 SERIAL « 0x01080004102002840742 (10 bytes) 09:56:55.255 SERIAL » [ACK] (0x06) 09:56:55.256 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:56:55.259 CNTRLR « [Node 032] received wakeup notification 09:56:55.311 SERIAL « 0x01080004102002840742 (10 bytes) 09:56:55.311 SERIAL » [ACK] (0x06) 09:56:55.312 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:56:55.314 CNTRLR « [Node 032] received wakeup notification 09:56:55.325 SERIAL « 0x01080004102002840742 (10 bytes) 09:56:55.326 SERIAL » [ACK] (0x06) 09:56:55.327 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:56:55.328 CNTRLR « [Node 032] received wakeup notification 09:56:55.389 SERIAL « 0x01080004102002840742 (10 bytes) 09:56:55.390 SERIAL » [ACK] (0x06) 09:56:55.390 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:56:55.392 CNTRLR « [Node 032] received wakeup notification 09:56:55.527 SERIAL « 0x01080004102002840742 (10 bytes) 09:56:55.528 SERIAL » [ACK] (0x06) 09:56:55.529 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:56:55.531 CNTRLR « [Node 032] received wakeup notification 09:56:55.587 SERIAL « 0x01080004102002840742 (10 bytes) 09:56:55.588 SERIAL » [ACK] (0x06) 09:56:55.589 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 09:56:55.591 CNTRLR « [Node 032] received wakeup notification 09:56:56.591 CNTRLR » [Node 032] Sending node back to sleep... 09:56:56.595 SERIAL » 0x0109001320028408255836 (11 bytes) 09:56:56.595 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 88 └─[WakeUpCCNoMoreInformation] 09:56:56.597 SERIAL « [ACK] (0x06) 09:56:56.603 SERIAL « 0x0104011301e8 (6 bytes) 09:56:56.606 SERIAL » [ACK] (0x06) 09:56:56.607 DRIVER « [RES] [SendData] was sent: true 09:56:56.665 SERIAL « 0x0107001358000006b5 (9 bytes) 09:56:56.666 SERIAL » [ACK] (0x06) 09:56:56.667 DRIVER « [REQ] [SendData] callback id: 88 transmit status: OK 09:56:56.672 CNTRLR [Node 032] The node is now asleep. 09:56:56.674 CNTRLR [Node 032] Node asleep 09:57:00.427 SERIAL « 0x010c00040003063105042207ea0d (14 bytes) 09:57:00.428 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:57:00.429 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 122 => 202.6 [Endpoint 0] 09:57:00.429 SERIAL » [ACK] (0x06) 09:57:00.430 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 202.6 09:57:01.427 SERIAL « 0x010c00040003063105042204688c (14 bytes) 09:57:01.428 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:57:01.430 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 202.6 => 112.8 [Endpoint 0] 09:57:01.430 SERIAL » [ACK] (0x06) 09:57:01.432 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 112.8 09:57:02.105 SERIAL « 0x010900040008033003ff35 (11 bytes) 09:57:02.106 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:57:02.107 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:57:02.108 SERIAL » [ACK] (0x06) 09:57:02.109 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:57:02.160 SERIAL « 0x010900040008032001ff27 (11 bytes) 09:57:02.160 SERIAL » [ACK] (0x06) 09:57:02.161 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:57:02.163 CNTRLR [Node 008] treating BasicCC Set as a report 09:57:02.163 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:57:03.428 SERIAL « 0x010c00040003063105042209769f (14 bytes) 09:57:03.429 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:57:03.430 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 112.8 => 242.2 [Endpoint 0] 09:57:03.431 SERIAL » [ACK] (0x06) 09:57:03.433 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 242.2 09:57:05.428 SERIAL « 0x010c00040003063105042206f81e (14 bytes) 09:57:05.429 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:57:05.430 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 242.2 => 178.4 [Endpoint 0] 09:57:05.431 SERIAL » [ACK] (0x06) 09:57:05.433 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 178.4 09:57:08.428 SERIAL « 0x010c00040003063105042204ac48 (14 bytes) 09:57:08.429 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:57:08.430 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 178.4 => 119.6 [Endpoint 0] 09:57:08.430 SERIAL » [ACK] (0x06) 09:57:08.432 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 119.6 09:57:19.429 SERIAL « 0x010c000400030631050422096c85 (14 bytes) 09:57:19.431 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:57:19.432 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 119.6 => 241.2 [Endpoint 0] 09:57:19.433 SERIAL » [ACK] (0x06) 09:57:19.435 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 241.2 09:57:20.240 SERIAL « 0x01090004001b033003ff26 (11 bytes) 09:57:20.241 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:57:20.243 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:57:20.243 SERIAL » [ACK] (0x06) 09:57:20.245 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:57:20.295 SERIAL « 0x01090004001b032001ff34 (11 bytes) 09:57:20.295 SERIAL » [ACK] (0x06) 09:57:20.297 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:57:20.299 CNTRLR [Node 027] treating BasicCC Set as a report 09:57:20.299 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:57:21.430 SERIAL « 0x010c00040003063105042203d132 (14 bytes) 09:57:21.431 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:57:21.432 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 241.2 => 97.7 [Endpoint 0] 09:57:21.433 SERIAL » [ACK] (0x06) 09:57:21.435 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 97.7 09:57:22.430 SERIAL « 0x010c00040003063105042204a145 (14 bytes) 09:57:22.432 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:57:22.433 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 97.7 => 118.5 [Endpoint 0] 09:57:22.434 SERIAL » [ACK] (0x06) 09:57:22.436 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 118.5 09:57:25.508 SERIAL « 0x01090004001e033003ff23 (11 bytes) 09:57:25.509 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:57:25.510 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:57:25.511 SERIAL » [ACK] (0x06) 09:57:25.513 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:57:25.538 SERIAL » 0x010e00131f07600d00012501ff255931 (16 bytes) 09:57:25.539 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 89 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCSet] target value: true 09:57:25.541 SERIAL « [ACK] (0x06) 09:57:25.548 SERIAL « 0x0104011301e8 (6 bytes) 09:57:25.548 SERIAL » [ACK] (0x06) 09:57:25.549 DRIVER « [RES] [SendData] was sent: true 09:57:25.562 SERIAL « 0x01090004001e032001ff31 (11 bytes) 09:57:25.563 SERIAL » [ACK] (0x06) 09:57:25.564 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:57:25.566 CNTRLR [Node 030] treating BasicCC Set as a report 09:57:25.566 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:57:25.607 SERIAL « 0x0107001359000007b5 (9 bytes) 09:57:25.607 SERIAL » [ACK] (0x06) 09:57:25.608 DRIVER « [REQ] [SendData] callback id: 89 transmit status: OK 09:57:25.618 SERIAL » 0x010d00131f06600d00012502255acc (15 bytes) 09:57:25.619 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 90 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 09:57:25.621 SERIAL « [ACK] (0x06) 09:57:25.627 SERIAL « 0x0104011301e8 (6 bytes) 09:57:25.627 SERIAL » [ACK] (0x06) 09:57:25.628 DRIVER « [RES] [SendData] was sent: true 09:57:25.645 SERIAL « 0x010700135a000002b3 (9 bytes) 09:57:25.645 SERIAL » [ACK] (0x06) 09:57:25.646 DRIVER « [REQ] [SendData] callback id: 90 transmit status: OK 09:57:25.656 SERIAL « 0x010d0004001f07600d01002503ff5b (15 bytes) 09:57:25.657 CNTRLR [Node 031] [~] [Binary Switch] currentValue: false => true [Endpoint 1] 09:57:25.658 SERIAL » [ACK] (0x06) 09:57:25.659 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: true 09:57:25.821 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 09:57:25.822 SERIAL » [ACK] (0x06) 09:57:25.823 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 09:57:25.825 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 09:57:28.430 SERIAL « 0x010c00040003063105042209ff16 (14 bytes) 09:57:28.431 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:57:28.433 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 118.5 => 255.9 [Endpoint 0] 09:57:28.434 SERIAL » [ACK] (0x06) 09:57:28.436 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 255.9 09:57:29.431 SERIAL « 0x010c00040003063105042204a84c (14 bytes) 09:57:29.432 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:57:29.433 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 255.9 => 119.2 [Endpoint 0] 09:57:29.434 SERIAL » [ACK] (0x06) 09:57:29.436 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 119.2 09:57:32.959 SERIAL « 0x01090004000803300300ca (11 bytes) 09:57:32.960 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:57:32.960 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:57:32.961 SERIAL » [ACK] (0x06) 09:57:32.962 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:57:33.013 SERIAL « 0x01090004000803200100d8 (11 bytes) 09:57:33.014 SERIAL » [ACK] (0x06) 09:57:33.014 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:57:33.015 CNTRLR [Node 008] treating BasicCC Set as a report 09:57:33.016 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:57:34.095 SERIAL « 0x010900040008033003ff35 (11 bytes) 09:57:34.098 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:57:34.100 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => true [Endpoint 0] 09:57:34.101 SERIAL » [ACK] (0x06) 09:57:34.103 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 09:57:34.149 SERIAL « 0x010900040008032001ff27 (11 bytes) 09:57:34.150 SERIAL » [ACK] (0x06) 09:57:34.151 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 09:57:34.152 CNTRLR [Node 008] treating BasicCC Set as a report 09:57:34.153 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => true [Endpoint 0] 09:57:41.432 SERIAL « 0x010c00040003063105042207cd2a (14 bytes) 09:57:41.433 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:57:41.434 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 119.2 => 199.7 [Endpoint 0] 09:57:41.435 SERIAL » [ACK] (0x06) 09:57:41.437 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 199.7 09:57:52.433 SERIAL « 0x010c00040003063105042209846d (14 bytes) 09:57:52.434 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:57:52.435 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 199.7 => 243.6 [Endpoint 0] 09:57:52.436 SERIAL » [ACK] (0x06) 09:57:52.438 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 243.6 09:57:53.433 SERIAL « 0x010c00040003063105042204698d (14 bytes) 09:57:53.434 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:57:53.435 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 243.6 => 112.9 [Endpoint 0] 09:57:53.435 SERIAL » [ACK] (0x06) 09:57:53.436 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 112.9 09:58:05.219 SERIAL « 0x01090004100803300300da (11 bytes) 09:58:05.220 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:58:05.221 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:58:05.222 SERIAL » [ACK] (0x06) 09:58:05.224 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:58:05.274 SERIAL « 0x01090004100803300300da (11 bytes) 09:58:05.276 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:58:05.277 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:05.278 SERIAL » [ACK] (0x06) 09:58:05.280 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:58:05.316 SERIAL « 0x01090004100803300300da (11 bytes) 09:58:05.317 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:58:05.318 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:05.318 SERIAL » [ACK] (0x06) 09:58:05.320 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:58:05.353 SERIAL « 0x01090004100803300300da (11 bytes) 09:58:05.355 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:58:05.356 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:05.357 SERIAL » [ACK] (0x06) 09:58:05.359 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:58:05.392 SERIAL « 0x01090004100803300300da (11 bytes) 09:58:05.393 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:58:05.394 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:05.395 SERIAL » [ACK] (0x06) 09:58:05.396 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:58:05.433 SERIAL « 0x01090004100803300300da (11 bytes) 09:58:05.433 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:58:05.434 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:05.435 SERIAL » [ACK] (0x06) 09:58:05.436 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:58:05.489 SERIAL « 0x01090004000803200100d8 (11 bytes) 09:58:05.490 SERIAL » [ACK] (0x06) 09:58:05.491 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:58:05.492 CNTRLR [Node 008] treating BasicCC Set as a report 09:58:05.493 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:05.498 SERIAL « 0x01090004100803300300da (11 bytes) 09:58:05.499 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:58:05.500 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:05.501 SERIAL » [ACK] (0x06) 09:58:05.503 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:58:05.616 SERIAL « 0x01090004100803300300da (11 bytes) 09:58:05.617 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:58:05.618 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:05.618 SERIAL » [ACK] (0x06) 09:58:05.620 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:58:05.654 SERIAL « 0x01090004100803300300da (11 bytes) 09:58:05.655 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:58:05.656 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:05.657 SERIAL » [ACK] (0x06) 09:58:05.658 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:58:05.908 SERIAL « 0x01090004100803300300da (11 bytes) 09:58:05.909 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:58:05.910 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:05.911 SERIAL » [ACK] (0x06) 09:58:05.913 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:58:05.956 SERIAL « 0x01090004100803300300da (11 bytes) 09:58:05.957 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:58:05.958 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:05.962 SERIAL » [ACK] (0x06) 09:58:05.964 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:58:06.031 SERIAL « 0x01090004100803200100c8 (11 bytes) 09:58:06.031 SERIAL » [ACK] (0x06) 09:58:06.032 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:58:06.034 CNTRLR [Node 008] treating BasicCC Set as a report 09:58:06.035 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:06.082 SERIAL « 0x01090004100803200100c8 (11 bytes) 09:58:06.082 SERIAL » [ACK] (0x06) 09:58:06.083 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:58:06.085 CNTRLR [Node 008] treating BasicCC Set as a report 09:58:06.086 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:06.093 SERIAL « 0x01090004100803200100c8 (11 bytes) 09:58:06.094 SERIAL » [ACK] (0x06) 09:58:06.095 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:58:06.097 CNTRLR [Node 008] treating BasicCC Set as a report 09:58:06.097 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:06.103 SERIAL « 0x01090004100803200100c8 (11 bytes) 09:58:06.104 SERIAL » [ACK] (0x06) 09:58:06.105 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:58:06.107 CNTRLR [Node 008] treating BasicCC Set as a report 09:58:06.107 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:06.219 SERIAL « 0x01090004100803200100c8 (11 bytes) 09:58:06.220 SERIAL » [ACK] (0x06) 09:58:06.221 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:58:06.223 CNTRLR [Node 008] treating BasicCC Set as a report 09:58:06.223 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:06.266 SERIAL « 0x01090004100803200100c8 (11 bytes) 09:58:06.266 SERIAL » [ACK] (0x06) 09:58:06.268 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:58:06.270 CNTRLR [Node 008] treating BasicCC Set as a report 09:58:06.271 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:06.361 SERIAL « 0x01090004100803200100c8 (11 bytes) 09:58:06.361 SERIAL » [ACK] (0x06) 09:58:06.363 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:58:06.365 CNTRLR [Node 008] treating BasicCC Set as a report 09:58:06.366 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:06.435 SERIAL « 0x01090004100803200100c8 (11 bytes) 09:58:06.436 SERIAL » [ACK] (0x06) 09:58:06.437 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:58:06.439 CNTRLR [Node 008] treating BasicCC Set as a report 09:58:06.439 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:06.534 SERIAL « 0x01090004100803200100c8 (11 bytes) 09:58:06.535 SERIAL » [ACK] (0x06) 09:58:06.536 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:58:06.541 CNTRLR [Node 008] treating BasicCC Set as a report 09:58:06.541 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:06.549 SERIAL « 0x01090004100803200100c8 (11 bytes) 09:58:06.550 SERIAL » [ACK] (0x06) 09:58:06.551 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:58:06.553 CNTRLR [Node 008] treating BasicCC Set as a report 09:58:06.553 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:06.608 SERIAL « 0x01090004100803200100c8 (11 bytes) 09:58:06.609 SERIAL » [ACK] (0x06) 09:58:06.610 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:58:06.612 CNTRLR [Node 008] treating BasicCC Set as a report 09:58:06.612 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:08.414 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 09:58:08.414 SERIAL » [ACK] (0x06) 09:58:08.415 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  09:58:08.416 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 09:58:09.267 SERIAL « 0x01090004001e03300300dc (11 bytes) 09:58:09.268 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:58:09.269 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:58:09.269 SERIAL » [ACK] (0x06) 09:58:09.271 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:58:09.321 SERIAL « 0x01090004001e03200100ce (11 bytes) 09:58:09.322 SERIAL » [ACK] (0x06) 09:58:09.323 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:58:09.324 CNTRLR [Node 030] treating BasicCC Set as a report 09:58:09.325 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:58:11.921 SERIAL « 0x01090004001b03300300d9 (11 bytes) 09:58:11.922 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 09:58:11.923 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 09:58:11.925 SERIAL » [ACK] (0x06) 09:58:11.927 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 09:58:11.975 SERIAL « 0x01090004001b03200100cb (11 bytes) 09:58:11.975 SERIAL » [ACK] (0x06) 09:58:11.976 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 09:58:11.977 CNTRLR [Node 027] treating BasicCC Set as a report 09:58:11.977 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 09:59:09.294 SERIAL » 0x010e00131f07600d0001250100255bcc (16 bytes) 09:59:09.294 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 91 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCSet] target value: false 09:59:09.297 SERIAL « [ACK] (0x06) 09:59:09.303 SERIAL « 0x0104011301e8 (6 bytes) 09:59:09.304 SERIAL » [ACK] (0x06) 09:59:09.305 DRIVER « [RES] [SendData] was sent: true 09:59:09.322 SERIAL « 0x010700135b000002b2 (9 bytes) 09:59:09.322 SERIAL » [ACK] (0x06) 09:59:09.323 DRIVER « [REQ] [SendData] callback id: 91 transmit status: OK 09:59:09.338 SERIAL » 0x010d00131f06600d00012502255cca (15 bytes) 09:59:09.339 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 92 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 09:59:09.342 SERIAL « [ACK] (0x06) 09:59:09.348 SERIAL « 0x0104011301e8 (6 bytes) 09:59:09.349 SERIAL » [ACK] (0x06) 09:59:09.350 DRIVER « [RES] [SendData] was sent: true 09:59:09.366 SERIAL « 0x010700135c000003b4 (9 bytes) 09:59:09.366 SERIAL » [ACK] (0x06) 09:59:09.366 DRIVER « [REQ] [SendData] callback id: 92 transmit status: OK 09:59:09.375 SERIAL « 0x010d0004001f07600d0100250300a4 (15 bytes) 09:59:09.376 CNTRLR [Node 031] [~] [Binary Switch] currentValue: true => false [Endpoint 1] 09:59:09.376 SERIAL » [ACK] (0x06) 09:59:09.377 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: false 09:59:12.440 SERIAL « 0x010c00040003063105042205c82d (14 bytes) 09:59:12.441 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:59:12.442 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 112.9 => 148 [Endpoint 0] 09:59:12.443 SERIAL » [ACK] (0x06) 09:59:12.444 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 148 09:59:25.442 SERIAL « 0x010c000400030631050422076483 (14 bytes) 09:59:25.443 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:59:25.444 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 148 => 189.2 [Endpoint 0] 09:59:25.445 SERIAL » [ACK] (0x06) 09:59:25.446 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 189.2 09:59:49.402 SERIAL « 0x01100004001d0a600d02003105012200bb3f (18 bytes) 09:59:49.403 CNTRLR [Node 029] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 09:59:49.404 CNTRLR [Node 029] [~] [Multilevel Sensor] Air temperature: 18.5 => 18.7 [Endpoint 2] 09:59:49.405 SERIAL » [ACK] (0x06) 09:59:49.407 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.7 09:59:50.445 SERIAL « 0x010c00040003063105042208f911 (14 bytes) 09:59:50.446 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:59:50.447 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 189.2 => 229.7 [Endpoint 0] 09:59:50.447 SERIAL » [ACK] (0x06) 09:59:50.449 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 229.7 09:59:53.445 SERIAL « 0x010c000400030631050422066c8a (14 bytes) 09:59:53.446 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:59:53.446 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 229.7 => 164.4 [Endpoint 0] 09:59:53.447 SERIAL » [ACK] (0x06) 09:59:53.448 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 164.4 09:59:54.445 SERIAL « 0x010c000400030631050422046c88 (14 bytes) 09:59:54.446 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:59:54.447 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 164.4 => 113.2 [Endpoint 0] 09:59:54.448 SERIAL » [ACK] (0x06) 09:59:54.450 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 113.2 09:59:56.445 SERIAL « 0x010c000400030631050422085eb6 (14 bytes) 09:59:56.446 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:59:56.447 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 113.2 => 214.2 [Endpoint 0] 09:59:56.448 SERIAL » [ACK] (0x06) 09:59:56.450 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 214.2 09:59:57.446 SERIAL « 0x010c0004000306310504220426c2 (14 bytes) 09:59:57.447 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:59:57.448 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 214.2 => 106.2 [Endpoint 0] 09:59:57.449 SERIAL » [ACK] (0x06) 09:59:57.451 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 106.2 09:59:59.446 SERIAL « 0x010c00040003063105042205dc39 (14 bytes) 09:59:59.448 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 09:59:59.449 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 106.2 => 150 [Endpoint 0] 09:59:59.450 SERIAL » [ACK] (0x06) 09:59:59.451 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 150 10:00:00.034 CNTRLR » [Node 010] pinging the node... 10:00:00.042 SERIAL » 0x010800130a0100255d97 (10 bytes) 10:00:00.043 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 93 └─[NoOperationCC] 10:00:00.044 SERIAL « [ACK] (0x06) 10:00:00.054 SERIAL « 0x0104011301e8 (6 bytes) 10:00:00.054 SERIAL » [ACK] (0x06) 10:00:00.055 DRIVER « [RES] [SendData] was sent: true 10:00:00.446 SERIAL « 0x010c00040003063105042204b652 (14 bytes) 10:00:00.447 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:00:00.448 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 150 => 120.6 [Endpoint 0] 10:00:00.449 SERIAL » [ACK] (0x06) 10:00:00.450 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 120.6 10:00:02.473 SERIAL « 0x010c00040003063105042208fc14 (14 bytes) 10:00:02.474 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:00:02.474 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 120.6 => 230 [Endpoint 0] 10:00:02.475 SERIAL » [ACK] (0x06) 10:00:02.475 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 230 10:00:08.049 SERIAL « 0x010700135d01032094 (9 bytes) 10:00:08.049 SERIAL » [ACK] (0x06) 10:00:08.049 DRIVER « [REQ] [SendData] callback id: 93 transmit status: NoAck 10:00:08.054 CNTRLR [Node 010] Node 10 did not respond after 1 attempts, it is presumed dead 10:00:08.056 CNTRLR [Node 010] ping failed: Failed to send the command after 1 attempts (Status No Ack) 10:00:27.448 SERIAL « 0x010c000400030631050422051df8 (14 bytes) 10:00:27.450 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:00:27.451 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 230 => 130.9 [Endpoint 0] 10:00:27.452 SERIAL » [ACK] (0x06) 10:00:27.453 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 130.9 10:00:38.449 SERIAL « 0x010c000400030631050422091cf5 (14 bytes) 10:00:38.450 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:00:38.451 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 130.9 => 233.2 [Endpoint 0] 10:00:38.452 SERIAL » [ACK] (0x06) 10:00:38.453 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 233.2 10:00:39.450 SERIAL « 0x010c00040003063105042204b753 (14 bytes) 10:00:39.451 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:00:39.452 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 233.2 => 120.7 [Endpoint 0] 10:00:39.452 SERIAL » [ACK] (0x06) 10:00:39.454 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 120.7 10:00:43.936 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:00:43.937 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:00:43.937 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:00:43.937 SERIAL » [ACK] (0x06) 10:00:43.938 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:00:43.985 SERIAL « 0x01090004002003200100f0 (11 bytes) 10:00:43.985 SERIAL » [ACK] (0x06) 10:00:43.986 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 10:00:43.987 CNTRLR [Node 032] treating BasicCC Set as a report 10:00:43.987 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:00:44.027 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:00:44.028 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:00:44.028 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:00:44.029 SERIAL » [ACK] (0x06) 10:00:44.030 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:00:44.057 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:00:44.058 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:00:44.059 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:00:44.059 SERIAL » [ACK] (0x06) 10:00:44.060 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:00:44.069 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:00:44.069 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:00:44.070 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:00:44.070 SERIAL » [ACK] (0x06) 10:00:44.071 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:00:44.147 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:00:44.148 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:00:44.148 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:00:44.149 SERIAL » [ACK] (0x06) 10:00:44.149 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:00:44.190 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:00:44.191 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:00:44.192 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:00:44.192 SERIAL » [ACK] (0x06) 10:00:44.193 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:00:44.208 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:00:44.208 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:00:44.213 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:00:44.213 SERIAL » [ACK] (0x06) 10:00:44.214 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:00:44.339 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:00:44.340 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:00:44.340 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:00:44.341 SERIAL » [ACK] (0x06) 10:00:44.341 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:00:44.401 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:00:44.401 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:00:44.402 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:00:44.402 SERIAL » [ACK] (0x06) 10:00:44.403 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:00:44.437 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:00:44.437 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:00:44.438 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:00:44.439 SERIAL » [ACK] (0x06) 10:00:44.440 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:00:44.494 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:00:44.495 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:00:44.496 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:00:44.497 SERIAL » [ACK] (0x06) 10:00:44.498 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:00:44.592 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:00:44.593 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:00:44.594 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:00:44.594 SERIAL » [ACK] (0x06) 10:00:44.595 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:00:53.887 SERIAL « 0x010900040008033003ff35 (11 bytes) 10:00:53.888 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:00:53.888 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:00:53.889 SERIAL » [ACK] (0x06) 10:00:53.889 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:00:54.345 SERIAL « 0x010900040008032001ff27 (11 bytes) 10:00:54.346 SERIAL » [ACK] (0x06) 10:00:54.347 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:00:54.349 CNTRLR [Node 008] treating BasicCC Set as a report 10:00:54.350 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:01:05.528 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 10:01:05.529 SERIAL » [ACK] (0x06) 10:01:05.530 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 10:01:05.533 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 10:01:09.390 SERIAL « 0x01090004001e033003ff23 (11 bytes) 10:01:09.391 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:01:09.393 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:01:09.393 SERIAL » [ACK] (0x06) 10:01:09.395 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:01:09.418 SERIAL » 0x010e00131f07600d00012501ff255e36 (16 bytes) 10:01:09.419 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 94 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCSet] target value: true 10:01:09.421 SERIAL « [ACK] (0x06) 10:01:09.428 SERIAL « 0x0104011301e8 (6 bytes) 10:01:09.428 SERIAL » [ACK] (0x06) 10:01:09.429 DRIVER « [RES] [SendData] was sent: true 10:01:09.445 SERIAL « 0x01090004001e032001ff31 (11 bytes) 10:01:09.445 SERIAL » [ACK] (0x06) 10:01:09.447 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:01:09.449 CNTRLR [Node 030] treating BasicCC Set as a report 10:01:09.450 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:01:09.489 SERIAL « 0x010700135e000007b2 (9 bytes) 10:01:09.489 SERIAL » [ACK] (0x06) 10:01:09.489 DRIVER « [REQ] [SendData] callback id: 94 transmit status: OK 10:01:09.497 SERIAL » 0x010d00131f06600d00012502255fc9 (15 bytes) 10:01:09.498 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 95 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 10:01:09.499 SERIAL « [ACK] (0x06) 10:01:09.506 SERIAL « 0x0104011301e8 (6 bytes) 10:01:09.506 SERIAL » [ACK] (0x06) 10:01:09.506 DRIVER « [RES] [SendData] was sent: true 10:01:09.524 SERIAL « 0x010700135f000002b6 (9 bytes) 10:01:09.524 SERIAL » [ACK] (0x06) 10:01:09.524 DRIVER « [REQ] [SendData] callback id: 95 transmit status: OK 10:01:09.535 SERIAL « 0x010d0004001f07600d01002503ff5b (15 bytes) 10:01:09.536 CNTRLR [Node 031] [~] [Binary Switch] currentValue: false => true [Endpoint 1] 10:01:09.536 SERIAL » [ACK] (0x06) 10:01:09.537 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: true 10:01:10.937 SERIAL « 0x01090004001b033003ff26 (11 bytes) 10:01:10.938 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:01:10.939 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:01:10.939 SERIAL » [ACK] (0x06) 10:01:10.941 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:01:10.991 SERIAL « 0x01090004001b032001ff34 (11 bytes) 10:01:10.992 SERIAL » [ACK] (0x06) 10:01:10.993 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:01:10.995 CNTRLR [Node 027] treating BasicCC Set as a report 10:01:10.995 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:01:24.584 SERIAL « 0x01090004000803300300ca (11 bytes) 10:01:24.585 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:01:24.586 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:01:24.587 SERIAL » [ACK] (0x06) 10:01:24.588 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:01:24.639 SERIAL « 0x01090004000803200100d8 (11 bytes) 10:01:24.640 SERIAL » [ACK] (0x06) 10:01:24.641 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 10:01:24.644 CNTRLR [Node 008] treating BasicCC Set as a report 10:01:24.644 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:01:36.627 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 10:01:36.628 SERIAL » [ACK] (0x06) 10:01:36.629 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  10:01:36.632 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 10:01:39.541 SERIAL « 0x01090004001e03300300dc (11 bytes) 10:01:39.542 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:01:39.543 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:01:39.543 SERIAL » [ACK] (0x06) 10:01:39.545 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:01:39.595 SERIAL « 0x01090004001e03200100ce (11 bytes) 10:01:39.596 SERIAL » [ACK] (0x06) 10:01:39.597 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 10:01:39.599 CNTRLR [Node 030] treating BasicCC Set as a report 10:01:39.599 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:01:41.794 SERIAL « 0x01090004001b03300300d9 (11 bytes) 10:01:41.795 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:01:41.797 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:01:41.797 SERIAL » [ACK] (0x06) 10:01:41.799 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:01:41.849 SERIAL « 0x01090004001b03200100cb (11 bytes) 10:01:41.849 SERIAL » [ACK] (0x06) 10:01:41.850 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 10:01:41.852 CNTRLR [Node 027] treating BasicCC Set as a report 10:01:41.853 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:01:42.566 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:01:42.567 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:01:42.568 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:01:42.569 SERIAL » [ACK] (0x06) 10:01:42.570 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:01:42.611 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:01:42.612 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:01:42.613 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:01:42.613 SERIAL » [ACK] (0x06) 10:01:42.615 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:01:42.682 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:01:42.683 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:01:42.684 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:01:42.685 SERIAL » [ACK] (0x06) 10:01:42.686 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:01:42.724 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:01:42.725 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:01:42.726 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:01:42.727 SERIAL » [ACK] (0x06) 10:01:42.729 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:01:42.811 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:01:42.811 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:01:42.812 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:01:42.814 SERIAL » [ACK] (0x06) 10:01:42.815 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:01:42.930 SERIAL « 0x010900040020032001ff0f (11 bytes) 10:01:42.930 SERIAL » [ACK] (0x06) 10:01:42.931 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:01:42.932 CNTRLR [Node 032] treating BasicCC Set as a report 10:01:42.932 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:01:42.960 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:01:42.960 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:01:42.961 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:01:42.962 SERIAL » [ACK] (0x06) 10:01:42.963 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:01:43.066 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:01:43.066 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:01:43.067 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:01:43.067 SERIAL » [ACK] (0x06) 10:01:43.068 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:01:43.083 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:01:43.083 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:01:43.084 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:01:43.084 SERIAL » [ACK] (0x06) 10:01:43.085 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:01:43.276 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:01:43.276 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:01:43.277 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:01:43.277 SERIAL » [ACK] (0x06) 10:01:43.278 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:02:09.951 SERIAL « 0x01090004001b033003ff26 (11 bytes) 10:02:09.952 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:02:09.953 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:02:09.954 SERIAL » [ACK] (0x06) 10:02:09.956 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:02:10.005 SERIAL « 0x01090004001b032001ff34 (11 bytes) 10:02:10.006 SERIAL » [ACK] (0x06) 10:02:10.007 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:02:10.009 CNTRLR [Node 027] treating BasicCC Set as a report 10:02:10.010 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:02:10.123 SERIAL « 0x010c00040002063105030a000bc5 (14 bytes) 10:02:10.123 CNTRLR [Node 002] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 10:02:10.124 CNTRLR [Node 002] [~] [Multilevel Sensor] Illuminance: 12 => 11 [Endpoint 0] 10:02:10.125 SERIAL » [ACK] (0x06) 10:02:10.126 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 11 10:02:39.564 SERIAL » 0x010e00131f07600d00012501002560f7 (16 bytes) 10:02:39.565 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 96 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCSet] target value: false 10:02:39.567 SERIAL « [ACK] (0x06) 10:02:39.574 SERIAL « 0x0104011301e8 (6 bytes) 10:02:39.574 SERIAL » [ACK] (0x06) 10:02:39.575 DRIVER « [RES] [SendData] was sent: true 10:02:39.592 SERIAL « 0x010700136000000289 (9 bytes) 10:02:39.592 SERIAL » [ACK] (0x06) 10:02:39.593 DRIVER « [REQ] [SendData] callback id: 96 transmit status: OK 10:02:39.606 SERIAL » 0x010d00131f06600d000125022561f7 (15 bytes) 10:02:39.607 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 97 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 10:02:39.608 SERIAL « [ACK] (0x06) 10:02:39.615 SERIAL « 0x0104011301e8 (6 bytes) 10:02:39.615 SERIAL » [ACK] (0x06) 10:02:39.616 DRIVER « [RES] [SendData] was sent: true 10:02:39.633 SERIAL « 0x010700136100000288 (9 bytes) 10:02:39.633 SERIAL » [ACK] (0x06) 10:02:39.634 DRIVER « [REQ] [SendData] callback id: 97 transmit status: OK 10:02:39.644 SERIAL « 0x010d0004001f07600d0100250300a4 (15 bytes) 10:02:39.645 CNTRLR [Node 031] [~] [Binary Switch] currentValue: true => false [Endpoint 1] 10:02:39.646 SERIAL » [ACK] (0x06) 10:02:39.647 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: false 10:02:48.085 SERIAL « 0x01090004001b03300300d9 (11 bytes) 10:02:48.086 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:02:48.087 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:02:48.088 SERIAL » [ACK] (0x06) 10:02:48.090 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:02:48.139 SERIAL « 0x01090004001b03200100cb (11 bytes) 10:02:48.140 SERIAL » [ACK] (0x06) 10:02:48.141 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 10:02:48.144 CNTRLR [Node 027] treating BasicCC Set as a report 10:02:48.144 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:03:40.657 SERIAL « 0x0108000400060298402f (10 bytes) 10:03:40.658 SERIAL » [ACK] (0x06) 10:03:40.660 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 10:03:40.671 SERIAL » 0x01110013060a988048fa1d1e70aa9554240067 (19 bytes) 10:03:40.672 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x48fa1d1e70aa9554 10:03:40.675 SERIAL « [ACK] (0x06) 10:03:40.681 SERIAL « 0x0104011301e8 (6 bytes) 10:03:40.682 SERIAL » [ACK] (0x06) 10:03:40.683 DRIVER « [RES] [SendData] was sent: true 10:03:40.724 SERIAL « 0x0124000400061e9881e08dcf5a5cdd8f8e24d48f695ee569beafda924831fc1fb (38 bytes) f93471f74a1 10:03:40.726 SERIAL » [ACK] (0x06) 10:03:40.728 CNTRLR [Node 006] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 10:03:40.729 CNTRLR [Node 006] [~] [Multilevel Sensor] Air temperature: 20.5 => 20.2 [Endpoint 2] 10:03:40.730 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 20.2 10:04:43.612 SERIAL « 0x01080004001b02840769 (10 bytes) 10:04:43.612 SERIAL » [ACK] (0x06) 10:04:43.613 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:04:43.615 CNTRLR « [Node 027] received wakeup notification 10:04:43.616 CNTRLR [Node 027] The node is now awake. 10:04:44.618 CNTRLR » [Node 027] Sending node back to sleep... 10:04:44.627 SERIAL » 0x010900131b028408256237 (11 bytes) 10:04:44.628 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 98 └─[WakeUpCCNoMoreInformation] 10:04:44.630 SERIAL « [ACK] (0x06) 10:04:44.636 SERIAL « 0x0104011301e8 (6 bytes) 10:04:44.636 SERIAL » [ACK] (0x06) 10:04:44.637 DRIVER « [RES] [SendData] was sent: true 10:04:44.653 SERIAL « 0x01070013620000028b (9 bytes) 10:04:44.654 SERIAL » [ACK] (0x06) 10:04:44.655 DRIVER « [REQ] [SendData] callback id: 98 transmit status: OK 10:04:44.660 CNTRLR [Node 027] The node is now asleep. 10:04:44.667 CNTRLR [Node 027] Node asleep 10:04:50.524 SERIAL « 0x010c00040003063105042203ef0c (14 bytes) 10:04:50.524 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:04:50.525 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 120.7 => 100.7 [Endpoint 0] 10:04:50.525 SERIAL » [ACK] (0x06) 10:04:50.526 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 100.7 10:04:51.475 SERIAL « 0x010c0004000306310504220954bd (14 bytes) 10:04:51.477 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:04:51.478 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 100.7 => 238.8 [Endpoint 0] 10:04:51.478 SERIAL » [ACK] (0x06) 10:04:51.480 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 238.8 10:04:52.476 SERIAL « 0x010c00040003063105042203fe1d (14 bytes) 10:04:52.477 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:04:52.478 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 238.8 => 102.2 [Endpoint 0] 10:04:52.479 SERIAL » [ACK] (0x06) 10:04:52.481 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 102.2 10:04:53.476 SERIAL « 0x010c00040003063105042204ad49 (14 bytes) 10:04:53.477 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:04:53.478 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 102.2 => 119.7 [Endpoint 0] 10:04:53.478 SERIAL » [ACK] (0x06) 10:04:53.480 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 119.7 10:04:54.476 SERIAL « 0x010c000400030631050422090ae3 (14 bytes) 10:04:54.477 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:04:54.478 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 119.7 => 231.4 [Endpoint 0] 10:04:54.478 SERIAL » [ACK] (0x06) 10:04:54.480 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 231.4 10:05:06.477 SERIAL « 0x010c00040003063105042204789c (14 bytes) 10:05:06.478 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:05:06.479 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 231.4 => 114.4 [Endpoint 0] 10:05:06.480 SERIAL » [ACK] (0x06) 10:05:06.482 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 114.4 10:05:25.479 SERIAL « 0x010c00040003063105042205ea0f (14 bytes) 10:05:25.480 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:05:25.481 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 114.4 => 151.4 [Endpoint 0] 10:05:25.482 SERIAL » [ACK] (0x06) 10:05:25.484 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 151.4 10:05:26.479 SERIAL « 0x010c00040003063105042204fb1f (14 bytes) 10:05:26.480 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:05:26.482 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 151.4 => 127.5 [Endpoint 0] 10:05:26.482 SERIAL » [ACK] (0x06) 10:05:26.484 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 127.5 10:06:48.675 SERIAL « 0x0110000400140a32022144000000fb00005b (18 bytes) 10:06:48.677 CNTRLR [Node 020] [~] [Meter] value[65537]: 2.51 => 2.51 [Endpoint 0] 10:06:48.678 CNTRLR [Node 020] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 10:06:48.679 SERIAL » [ACK] (0x06) 10:06:48.681 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 2.51 time delta: 0 seconds 10:08:02.613 SERIAL « 0x01090004000b0380034b32 (11 bytes) 10:08:02.615 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 10:08:02.616 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 10:08:02.617 SERIAL » [ACK] (0x06) 10:08:02.619 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 10:08:02.673 SERIAL « 0x010c0004000b0643030142019068 (14 bytes) 10:08:02.674 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpoint[1]: 4 => 4 [Endpoint 0] 10:08:02.675 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 10:08:02.676 SERIAL » [ACK] (0x06) 10:08:02.677 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 4 °C 10:08:02.729 SERIAL « 0x010a0004000b044608007fcf (12 bytes) 10:08:02.731 CNTRLR [Node 011] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 10:08:02.732 CNTRLR [Node 011] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 10:08:02.733 SERIAL » [ACK] (0x06) 10:08:02.734 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ClimateControlScheduleCCOverrideReport] override type: None override state: Unused 10:08:02.784 SERIAL « 0x01080004000b02840779 (10 bytes) 10:08:02.785 SERIAL » [ACK] (0x06) 10:08:02.786 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:08:02.788 CNTRLR « [Node 011] received wakeup notification 10:08:02.789 CNTRLR [Node 011] The node is now awake. 10:08:02.790 CNTRLR [Node 011] expects some queries after wake up, so it shall receive 10:08:02.790 CNTRLR [Node 011] compat query "Battery"::get() 10:08:02.799 SERIAL » 0x010900130b028002256328 (11 bytes) 10:08:02.800 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 99 └─[BatteryCCGet] 10:08:02.802 SERIAL « [ACK] (0x06) 10:08:02.809 SERIAL « 0x0104011301e8 (6 bytes) 10:08:02.810 SERIAL » [ACK] (0x06) 10:08:02.810 DRIVER « [RES] [SendData] was sent: true 10:08:02.828 SERIAL « 0x01070013630000038b (9 bytes) 10:08:02.828 SERIAL » [ACK] (0x06) 10:08:02.832 DRIVER « [REQ] [SendData] callback id: 99 transmit status: OK 10:08:02.838 SERIAL « 0x01090004000b0380034b32 (11 bytes) 10:08:02.839 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 10:08:02.840 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 10:08:02.840 SERIAL » [ACK] (0x06) 10:08:02.841 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 10:08:02.848 CNTRLR [Node 011] API call successful 10:08:02.849 CNTRLR [Node 011] compat query "Thermostat Setpoint"::get(1) 10:08:02.854 SERIAL » 0x010a00130b034302012564ef (12 bytes) 10:08:02.855 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 100 └─[ThermostatSetpointCCGet] setpoint type: Heating 10:08:02.857 SERIAL « [ACK] (0x06) 10:08:02.863 SERIAL « 0x0104011301e8 (6 bytes) 10:08:02.864 SERIAL » [ACK] (0x06) 10:08:02.865 DRIVER « [RES] [SendData] was sent: true 10:08:02.880 SERIAL « 0x01070013640000028d (9 bytes) 10:08:02.881 SERIAL » [ACK] (0x06) 10:08:02.881 DRIVER « [REQ] [SendData] callback id: 100 transmit status: OK 10:08:02.892 SERIAL « 0x010c0004000b0643030142019068 (14 bytes) 10:08:02.892 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpoint[1]: 4 => 4 [Endpoint 0] 10:08:02.893 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 10:08:02.894 SERIAL » [ACK] (0x06) 10:08:02.895 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 4 °C 10:08:02.897 CNTRLR [Node 011] API call successful 10:08:03.898 CNTRLR » [Node 011] Sending node back to sleep... 10:08:03.911 SERIAL » 0x010900130b028408256520 (11 bytes) 10:08:03.912 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 101 └─[WakeUpCCNoMoreInformation] 10:08:03.914 SERIAL « [ACK] (0x06) 10:08:03.920 SERIAL « 0x0104011301e8 (6 bytes) 10:08:03.921 SERIAL » [ACK] (0x06) 10:08:03.922 DRIVER « [RES] [SendData] was sent: true 10:08:03.937 SERIAL « 0x01070013650000038d (9 bytes) 10:08:03.938 SERIAL » [ACK] (0x06) 10:08:03.939 DRIVER « [REQ] [SendData] callback id: 101 transmit status: OK 10:08:03.944 CNTRLR [Node 011] The node is now asleep. 10:08:03.946 CNTRLR [Node 011] Node asleep 10:08:16.496 SERIAL « 0x010c000400030631050422098f66 (14 bytes) 10:08:16.497 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:08:16.498 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 127.5 => 244.7 [Endpoint 0] 10:08:16.498 SERIAL » [ACK] (0x06) 10:08:16.499 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 244.7 10:08:17.496 SERIAL « 0x010c000400030631050422045abe (14 bytes) 10:08:17.497 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:08:17.499 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 244.7 => 111.4 [Endpoint 0] 10:08:17.499 SERIAL » [ACK] (0x06) 10:08:17.501 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 111.4 10:08:26.118 SERIAL « 0x01080004001e0284076c (10 bytes) 10:08:26.119 SERIAL » [ACK] (0x06) 10:08:26.120 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:08:26.123 CNTRLR « [Node 030] received wakeup notification 10:08:26.124 CNTRLR [Node 030] The node is now awake. 10:08:26.378 SERIAL « 0x0108000400080284077a (10 bytes) 10:08:26.378 SERIAL » [ACK] (0x06) 10:08:26.380 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:08:26.382 CNTRLR « [Node 008] received wakeup notification 10:08:26.382 CNTRLR [Node 008] The node is now awake. 10:08:27.126 CNTRLR » [Node 030] Sending node back to sleep... 10:08:27.138 SERIAL » 0x010900131e028408256636 (11 bytes) 10:08:27.139 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 102 └─[WakeUpCCNoMoreInformation] 10:08:27.141 SERIAL « [ACK] (0x06) 10:08:27.147 SERIAL « 0x0104011301e8 (6 bytes) 10:08:27.148 SERIAL » [ACK] (0x06) 10:08:27.156 DRIVER « [RES] [SendData] was sent: true 10:08:27.164 SERIAL « 0x01070013660000028f (9 bytes) 10:08:27.165 SERIAL » [ACK] (0x06) 10:08:27.166 DRIVER « [REQ] [SendData] callback id: 102 transmit status: OK 10:08:27.172 CNTRLR [Node 030] The node is now asleep. 10:08:27.175 CNTRLR [Node 030] Node asleep 10:08:27.383 CNTRLR » [Node 008] Sending node back to sleep... 10:08:27.392 SERIAL » 0x0109001308028408256721 (11 bytes) 10:08:27.393 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 103 └─[WakeUpCCNoMoreInformation] 10:08:27.395 SERIAL « [ACK] (0x06) 10:08:27.401 SERIAL « 0x0104011301e8 (6 bytes) 10:08:27.402 SERIAL » [ACK] (0x06) 10:08:27.403 DRIVER « [RES] [SendData] was sent: true 10:08:27.480 SERIAL « 0x010700136700000985 (9 bytes) 10:08:27.480 SERIAL » [ACK] (0x06) 10:08:27.481 DRIVER « [REQ] [SendData] callback id: 103 transmit status: OK 10:08:27.486 CNTRLR [Node 008] The node is now asleep. 10:08:27.487 CNTRLR [Node 008] Node asleep 10:09:35.107 SERIAL « 0x01080004001502840767 (10 bytes) 10:09:35.108 SERIAL » [ACK] (0x06) 10:09:35.109 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:09:35.111 CNTRLR « [Node 021] received wakeup notification 10:09:35.111 CNTRLR [Node 021] The node is now awake. 10:09:36.113 CNTRLR » [Node 021] Sending node back to sleep... 10:09:36.124 SERIAL » 0x0109001315028408256833 (11 bytes) 10:09:36.125 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 104 └─[WakeUpCCNoMoreInformation] 10:09:36.127 SERIAL « [ACK] (0x06) 10:09:36.133 SERIAL « 0x0104011301e8 (6 bytes) 10:09:36.134 SERIAL » [ACK] (0x06) 10:09:36.134 DRIVER « [RES] [SendData] was sent: true 10:09:36.187 SERIAL « 0x010700136800000685 (9 bytes) 10:09:36.187 SERIAL » [ACK] (0x06) 10:09:36.189 DRIVER « [REQ] [SendData] callback id: 104 transmit status: OK 10:09:36.194 CNTRLR [Node 021] The node is now asleep. 10:09:36.196 CNTRLR [Node 021] Node asleep 10:10:17.015 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:10:17.016 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:10:17.018 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:10:17.019 SERIAL » [ACK] (0x06) 10:10:17.021 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:10:17.063 SERIAL « 0x01090004002003200100f0 (11 bytes) 10:10:17.064 SERIAL » [ACK] (0x06) 10:10:17.065 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 10:10:17.067 CNTRLR [Node 032] treating BasicCC Set as a report 10:10:17.067 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:10:17.135 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:10:17.136 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:10:17.137 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:10:17.137 SERIAL » [ACK] (0x06) 10:10:17.138 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:10:17.194 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:10:17.195 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:10:17.196 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:10:17.197 SERIAL » [ACK] (0x06) 10:10:17.198 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:10:17.290 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:10:17.291 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:10:17.292 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:10:17.293 SERIAL » [ACK] (0x06) 10:10:17.295 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:10:17.345 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:10:17.346 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:10:17.347 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:10:17.348 SERIAL » [ACK] (0x06) 10:10:17.349 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:10:17.395 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:10:17.396 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:10:17.397 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:10:17.398 SERIAL » [ACK] (0x06) 10:10:17.399 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:10:17.413 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:10:17.414 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:10:17.415 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:10:17.416 SERIAL » [ACK] (0x06) 10:10:17.417 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:10:17.463 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:10:17.464 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:10:17.464 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:10:17.465 SERIAL » [ACK] (0x06) 10:10:17.466 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:10:17.522 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:10:17.523 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:10:17.524 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:10:17.524 SERIAL » [ACK] (0x06) 10:10:17.525 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:10:17.643 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:10:17.644 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:10:17.645 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:10:17.645 SERIAL » [ACK] (0x06) 10:10:17.647 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:11:30.020 SERIAL « 0x01080004001102840763 (10 bytes) 10:11:30.021 SERIAL » [ACK] (0x06) 10:11:30.022 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:11:30.024 CNTRLR « [Node 017] received wakeup notification 10:11:30.025 CNTRLR [Node 017] The node is now awake. 10:11:31.027 CNTRLR » [Node 017] Sending node back to sleep... 10:11:31.036 SERIAL » 0x0109001311028408256936 (11 bytes) 10:11:31.036 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 105 └─[WakeUpCCNoMoreInformation] 10:11:31.039 SERIAL « [ACK] (0x06) 10:11:31.045 SERIAL « 0x0104011301e8 (6 bytes) 10:11:31.045 SERIAL » [ACK] (0x06) 10:11:31.046 DRIVER « [RES] [SendData] was sent: true 10:11:31.062 SERIAL « 0x010700136900000280 (9 bytes) 10:11:31.063 SERIAL » [ACK] (0x06) 10:11:31.064 DRIVER « [REQ] [SendData] callback id: 105 transmit status: OK 10:11:31.073 CNTRLR [Node 017] The node is now asleep. 10:11:31.090 CNTRLR [Node 017] Node asleep 10:11:59.494 SERIAL « 0x01080004102002840742 (10 bytes) 10:11:59.495 SERIAL » [ACK] (0x06) 10:11:59.496 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:11:59.498 CNTRLR « [Node 032] received wakeup notification 10:11:59.499 CNTRLR [Node 032] The node is now awake. 10:11:59.557 SERIAL « 0x01080004102002840742 (10 bytes) 10:11:59.558 SERIAL » [ACK] (0x06) 10:11:59.559 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:11:59.561 CNTRLR « [Node 032] received wakeup notification 10:11:59.660 SERIAL « 0x01080004102002840742 (10 bytes) 10:11:59.661 SERIAL » [ACK] (0x06) 10:11:59.662 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:11:59.664 CNTRLR « [Node 032] received wakeup notification 10:11:59.759 SERIAL « 0x01080004102002840742 (10 bytes) 10:11:59.760 SERIAL » [ACK] (0x06) 10:11:59.761 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:11:59.763 CNTRLR « [Node 032] received wakeup notification 10:11:59.773 SERIAL « 0x01080004102002840742 (10 bytes) 10:11:59.774 SERIAL » [ACK] (0x06) 10:11:59.775 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:11:59.777 CNTRLR « [Node 032] received wakeup notification 10:11:59.875 SERIAL « 0x01080004102002840742 (10 bytes) 10:11:59.876 SERIAL » [ACK] (0x06) 10:11:59.877 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:11:59.878 CNTRLR « [Node 032] received wakeup notification 10:11:59.935 SERIAL « 0x01080004102002840742 (10 bytes) 10:11:59.936 SERIAL » [ACK] (0x06) 10:11:59.937 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:11:59.940 CNTRLR « [Node 032] received wakeup notification 10:11:59.997 SERIAL « 0x01080004102002840742 (10 bytes) 10:11:59.998 SERIAL » [ACK] (0x06) 10:11:59.999 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:12:00.001 CNTRLR « [Node 032] received wakeup notification 10:12:00.079 SERIAL « 0x01080004102002840742 (10 bytes) 10:12:00.080 SERIAL » [ACK] (0x06) 10:12:00.081 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:12:00.082 CNTRLR « [Node 032] received wakeup notification 10:12:01.083 CNTRLR » [Node 032] Sending node back to sleep... 10:12:01.094 SERIAL » 0x0109001320028408256a04 (11 bytes) 10:12:01.094 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 106 └─[WakeUpCCNoMoreInformation] 10:12:01.097 SERIAL « [ACK] (0x06) 10:12:01.103 SERIAL « 0x0104011301e8 (6 bytes) 10:12:01.104 SERIAL » [ACK] (0x06) 10:12:01.105 DRIVER « [RES] [SendData] was sent: true 10:12:01.165 SERIAL « 0x010700136a00000687 (9 bytes) 10:12:01.165 SERIAL » [ACK] (0x06) 10:12:01.166 DRIVER « [REQ] [SendData] callback id: 106 transmit status: OK 10:12:01.170 CNTRLR [Node 032] The node is now asleep. 10:12:01.172 CNTRLR [Node 032] Node asleep 10:12:14.521 SERIAL « 0x010c0004000306310504220913fa (14 bytes) 10:12:14.522 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:12:14.523 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 111.4 => 232.3 [Endpoint 0] 10:12:14.524 SERIAL » [ACK] (0x06) 10:12:14.526 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 232.3 10:12:15.521 SERIAL « 0x010c00040003063105042203bd5e (14 bytes) 10:12:15.522 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:12:15.523 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 232.3 => 95.7 [Endpoint 0] 10:12:15.527 SERIAL » [ACK] (0x06) 10:12:15.529 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 95.7 10:12:16.521 SERIAL « 0x010c000400030631050422048c68 (14 bytes) 10:12:16.523 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:12:16.525 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 95.7 => 116.4 [Endpoint 0] 10:12:16.527 SERIAL » [ACK] (0x06) 10:12:16.529 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 116.4 10:12:47.035 SERIAL « 0x0110000400030a3202214400001f010000a9 (18 bytes) 10:12:47.037 CNTRLR [Node 003] [~] [Meter] value[65537]: 79.25 => 79.37 [Endpoint 0] 10:12:47.038 CNTRLR [Node 003] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 10:12:47.039 SERIAL » [ACK] (0x06) 10:12:47.041 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 79.37 time delta: 0 seconds 10:13:28.341 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:13:28.342 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:13:28.344 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:13:28.345 SERIAL » [ACK] (0x06) 10:13:28.346 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:13:28.462 SERIAL « 0x010900040020032001ff0f (11 bytes) 10:13:28.463 SERIAL » [ACK] (0x06) 10:13:28.464 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:13:28.465 CNTRLR [Node 032] treating BasicCC Set as a report 10:13:28.465 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:13:28.612 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:13:28.613 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:13:28.614 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:13:28.615 SERIAL » [ACK] (0x06) 10:13:28.619 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:13:28.692 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:13:28.693 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:13:28.694 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:13:28.695 SERIAL » [ACK] (0x06) 10:13:28.696 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:13:28.739 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:13:28.740 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:13:28.741 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:13:28.741 SERIAL » [ACK] (0x06) 10:13:28.743 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:13:28.792 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:13:28.793 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:13:28.794 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:13:28.794 SERIAL » [ACK] (0x06) 10:13:28.796 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:13:28.858 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:13:28.859 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:13:28.859 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:13:28.860 SERIAL » [ACK] (0x06) 10:13:28.861 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:13:28.975 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:13:28.976 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:13:28.977 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:13:28.978 SERIAL » [ACK] (0x06) 10:13:28.979 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:13:28.990 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:13:28.991 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:13:28.992 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:13:28.992 SERIAL » [ACK] (0x06) 10:13:28.994 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:14:05.937 SERIAL « 0x01090004001b033003ff26 (11 bytes) 10:14:05.940 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:14:05.942 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:14:05.942 SERIAL » [ACK] (0x06) 10:14:05.944 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:14:05.993 SERIAL « 0x01090004001b032001ff34 (11 bytes) 10:14:05.994 SERIAL » [ACK] (0x06) 10:14:05.995 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:14:05.998 CNTRLR [Node 027] treating BasicCC Set as a report 10:14:05.998 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:14:35.536 SERIAL « 0x010c000400030631050422063fd9 (14 bytes) 10:14:35.537 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:14:35.539 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 116.4 => 159.9 [Endpoint 0] 10:14:35.540 SERIAL » [ACK] (0x06) 10:14:35.541 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 159.9 10:14:36.535 SERIAL « 0x010c000400030631050422047692 (14 bytes) 10:14:36.536 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:14:36.537 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 159.9 => 114.2 [Endpoint 0] 10:14:36.537 SERIAL » [ACK] (0x06) 10:14:36.538 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 114.2 10:14:37.053 SERIAL « 0x01090004001b03300300d9 (11 bytes) 10:14:37.054 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:14:37.056 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:14:37.057 SERIAL » [ACK] (0x06) 10:14:37.059 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:14:37.106 SERIAL « 0x01090004001b03200100cb (11 bytes) 10:14:37.106 SERIAL » [ACK] (0x06) 10:14:37.108 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 10:14:37.111 CNTRLR [Node 027] treating BasicCC Set as a report 10:14:37.111 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:14:41.536 SERIAL « 0x010c000400030631050422053adf (14 bytes) 10:14:41.538 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:14:41.539 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 114.2 => 133.8 [Endpoint 0] 10:14:41.540 SERIAL » [ACK] (0x06) 10:14:41.542 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 133.8 10:15:42.386 SERIAL « 0x010c00040007063105012200c627 (14 bytes) 10:15:42.388 CNTRLR [Node 007] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 10:15:42.389 CNTRLR [Node 007] [~] [Multilevel Sensor] Air temperature: 20.3 => 19.8 [Endpoint 0] 10:15:42.390 SERIAL » [ACK] (0x06) 10:15:42.393 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 19.8 10:15:42.540 SERIAL « 0x010b0004000705310505014381 (13 bytes) 10:15:42.541 CNTRLR [Node 007] [Multilevel Sensor] Humidity: metadata updated [Endpoint 0] 10:15:42.542 CNTRLR [Node 007] [~] [Multilevel Sensor] Humidity: 65 => 67 [Endpoint 0] 10:15:42.545 SERIAL » [ACK] (0x06) 10:15:42.547 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Humidity scale: Percentage value value: 67 10:15:43.340 SERIAL « 0x0109000400070380036411 (11 bytes) 10:15:43.342 CNTRLR [Node 007] [~] [Battery] level: 100 => 100 [Endpoint 0] 10:15:43.343 CNTRLR [Node 007] [~] [Battery] isLow: false => false [Endpoint 0] 10:15:43.344 SERIAL » [ACK] (0x06) 10:15:43.346 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 10:15:43.420 SERIAL « 0x010c00040007063105030a0009c2 (14 bytes) 10:15:43.422 CNTRLR [Node 007] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 10:15:43.423 CNTRLR [Node 007] [~] [Multilevel Sensor] Illuminance: 5 => 9 [Endpoint 0] 10:15:43.424 SERIAL » [ACK] (0x06) 10:15:43.426 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 9 10:15:43.542 SERIAL « 0x010b000400070531051b0100dc (13 bytes) 10:15:43.543 CNTRLR [Node 007] [Multilevel Sensor] Ultraviolet: metadata updated [Endpoint 0] 10:15:43.545 CNTRLR [Node 007] [~] [Multilevel Sensor] Ultraviolet: 0 => 0 [Endpoint 0] 10:15:43.546 SERIAL » [ACK] (0x06) 10:15:43.551 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Ultraviolet scale: UV index value: 0 10:15:46.659 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:15:46.660 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:15:46.661 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:15:46.662 SERIAL » [ACK] (0x06) 10:15:46.664 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:15:46.754 SERIAL « 0x01090004002003200100f0 (11 bytes) 10:15:46.755 SERIAL » [ACK] (0x06) 10:15:46.756 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 10:15:46.758 CNTRLR [Node 032] treating BasicCC Set as a report 10:15:46.759 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:15:46.784 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:15:46.795 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:15:46.796 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:15:46.798 SERIAL » [ACK] (0x06) 10:15:46.800 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:15:46.805 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:15:46.806 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:15:46.808 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:15:46.809 SERIAL » [ACK] (0x06) 10:15:46.811 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:15:46.816 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:15:46.817 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:15:46.821 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:15:46.823 SERIAL » [ACK] (0x06) 10:15:46.825 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:15:46.919 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:15:46.920 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:15:46.921 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:15:46.921 SERIAL » [ACK] (0x06) 10:15:46.922 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:15:46.994 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:15:46.995 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:15:46.995 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:15:46.996 SERIAL » [ACK] (0x06) 10:15:46.997 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:15:47.057 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:15:47.058 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:15:47.059 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:15:47.060 SERIAL » [ACK] (0x06) 10:15:47.061 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:15:47.115 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:15:47.116 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:15:47.117 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:15:47.117 SERIAL » [ACK] (0x06) 10:15:47.118 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:15:47.172 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:15:47.173 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:15:47.173 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:15:47.174 SERIAL » [ACK] (0x06) 10:15:47.175 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:15:47.342 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:15:47.343 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:15:47.344 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:15:47.344 SERIAL » [ACK] (0x06) 10:15:47.345 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:15:47.384 SERIAL « 0x01090004102003300300f2 (11 bytes) 10:15:47.385 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:15:47.386 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:15:47.386 SERIAL » [ACK] (0x06) 10:15:47.387 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:15:55.671 SERIAL « 0x0110000400230a600d02003105012200c379 (18 bytes) 10:15:55.673 CNTRLR [Node 035] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 10:15:55.679 CNTRLR [Node 035] [~] [Multilevel Sensor] Air temperature: 19.2 => 19.5 [Endpoint 2] 10:15:55.681 SERIAL » [ACK] (0x06) 10:15:55.683 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 19.5 10:17:06.551 SERIAL « 0x010c000400030631050422047195 (14 bytes) 10:17:06.552 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:17:06.554 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 133.8 => 113.7 [Endpoint 0] 10:17:06.555 SERIAL » [ACK] (0x06) 10:17:06.557 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 113.7 10:17:22.763 SERIAL « 0x010c00040002063105030a000ec0 (14 bytes) 10:17:22.765 CNTRLR [Node 002] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 10:17:22.766 CNTRLR [Node 002] [~] [Multilevel Sensor] Illuminance: 11 => 14 [Endpoint 0] 10:17:22.767 SERIAL » [ACK] (0x06) 10:17:22.769 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 14 10:17:49.438 SERIAL « 0x01100004001d0a600d02003105012200bd39 (18 bytes) 10:17:49.440 CNTRLR [Node 029] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 10:17:49.441 CNTRLR [Node 029] [~] [Multilevel Sensor] Air temperature: 18.7 => 18.9 [Endpoint 2] 10:17:49.442 SERIAL » [ACK] (0x06) 10:17:49.444 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.9 10:19:47.301 SERIAL « 0x01080004001b02840769 (10 bytes) 10:19:47.303 SERIAL » [ACK] (0x06) 10:19:47.304 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:19:47.307 CNTRLR « [Node 027] received wakeup notification 10:19:47.309 CNTRLR [Node 027] The node is now awake. 10:19:48.311 CNTRLR » [Node 027] Sending node back to sleep... 10:19:48.325 SERIAL » 0x010900131b028408256b3e (11 bytes) 10:19:48.326 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 107 └─[WakeUpCCNoMoreInformation] 10:19:48.329 SERIAL « [ACK] (0x06) 10:19:48.335 SERIAL « 0x0104011301e8 (6 bytes) 10:19:48.335 SERIAL » [ACK] (0x06) 10:19:48.336 DRIVER « [RES] [SendData] was sent: true 10:19:48.351 SERIAL « 0x010700136b00000282 (9 bytes) 10:19:48.352 SERIAL » [ACK] (0x06) 10:19:48.353 DRIVER « [REQ] [SendData] callback id: 107 transmit status: OK 10:19:48.360 CNTRLR [Node 027] The node is now asleep. 10:19:48.362 CNTRLR [Node 027] Node asleep 10:20:27.572 SERIAL « 0x010c000400030631050422058f6a (14 bytes) 10:20:27.573 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:20:27.574 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 113.7 => 142.3 [Endpoint 0] 10:20:27.575 SERIAL » [ACK] (0x06) 10:20:27.578 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 142.3 10:20:28.571 SERIAL « 0x010c000400030631050422048165 (14 bytes) 10:20:28.572 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:20:28.573 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 142.3 => 115.3 [Endpoint 0] 10:20:28.573 SERIAL » [ACK] (0x06) 10:20:28.574 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 115.3 10:20:43.592 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:20:43.593 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:20:43.593 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:20:43.594 SERIAL » [ACK] (0x06) 10:20:43.595 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:20:43.640 SERIAL « 0x010900040020032001ff0f (11 bytes) 10:20:43.641 SERIAL » [ACK] (0x06) 10:20:43.641 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:20:43.643 CNTRLR [Node 032] treating BasicCC Set as a report 10:20:43.643 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:20:43.687 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:20:43.687 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:20:43.688 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:20:43.688 SERIAL » [ACK] (0x06) 10:20:43.689 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:20:43.856 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:20:43.857 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:20:43.858 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:20:43.859 SERIAL » [ACK] (0x06) 10:20:43.861 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:20:43.909 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:20:43.910 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:20:43.911 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:20:43.912 SERIAL » [ACK] (0x06) 10:20:43.914 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:20:44.004 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:20:44.005 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:20:44.006 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:20:44.007 SERIAL » [ACK] (0x06) 10:20:44.008 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:20:44.059 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:20:44.059 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:20:44.060 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:20:44.061 SERIAL » [ACK] (0x06) 10:20:44.063 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:20:44.117 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:20:44.118 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:20:44.119 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:20:44.120 SERIAL » [ACK] (0x06) 10:20:44.121 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:20:44.131 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:20:44.132 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:20:44.133 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:20:44.134 SERIAL » [ACK] (0x06) 10:20:44.135 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:20:44.212 SERIAL « 0x010900041020033003ff0d (11 bytes) 10:20:44.213 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:20:44.214 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:20:44.214 SERIAL » [ACK] (0x06) 10:20:44.216 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:20:52.400 SERIAL « 0x01090004001b033003ff26 (11 bytes) 10:20:52.401 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:20:52.403 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:20:52.404 SERIAL » [ACK] (0x06) 10:20:52.406 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:20:52.455 SERIAL « 0x01090004001b032001ff34 (11 bytes) 10:20:52.456 SERIAL » [ACK] (0x06) 10:20:52.457 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:20:52.460 CNTRLR [Node 027] treating BasicCC Set as a report 10:20:52.460 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:21:40.689 SERIAL « 0x0108000400060298402f (10 bytes) 10:21:40.690 SERIAL » [ACK] (0x06) 10:21:40.691 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 10:21:40.705 SERIAL » 0x01110013060a988026b11b0994ea2c8c240096 (19 bytes) 10:21:40.706 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x24 │ callback id: 0 └─[SecurityCCNonceReport] nonce: 0x26b11b0994ea2c8c 10:21:40.708 SERIAL « [ACK] (0x06) 10:21:40.715 SERIAL « 0x0104011301e8 (6 bytes) 10:21:40.715 SERIAL » [ACK] (0x06) 10:21:40.716 DRIVER « [RES] [SendData] was sent: true 10:21:40.758 SERIAL « 0x0124000400061e988127b9d001300424f5669bd5247d24694554b8e826c79d247 (38 bytes) 9de80f78d0c 10:21:40.761 SERIAL » [ACK] (0x06) 10:21:40.763 CNTRLR [Node 006] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 10:21:40.765 CNTRLR [Node 006] [~] [Multilevel Sensor] Air temperature: 20.2 => 20 [Endpoint 2] 10:21:40.766 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 20 10:21:52.715 SERIAL « 0x01090004001b03300300d9 (11 bytes) 10:21:52.717 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:21:52.718 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:21:52.721 SERIAL » [ACK] (0x06) 10:21:52.724 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:21:52.769 SERIAL « 0x01090004001b03200100cb (11 bytes) 10:21:52.770 SERIAL » [ACK] (0x06) 10:21:52.773 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 10:21:52.775 CNTRLR [Node 027] treating BasicCC Set as a report 10:21:52.775 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:21:54.473 SERIAL « 0x01090004001b033003ff26 (11 bytes) 10:21:54.474 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:21:54.475 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:21:54.476 SERIAL » [ACK] (0x06) 10:21:54.477 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:21:54.528 SERIAL « 0x01090004001b032001ff34 (11 bytes) 10:21:54.528 SERIAL » [ACK] (0x06) 10:21:54.529 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:21:54.531 CNTRLR [Node 027] treating BasicCC Set as a report 10:21:54.531 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:21:58.580 SERIAL « 0x010c000400030631050422056287 (14 bytes) 10:21:58.581 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:21:58.582 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 115.3 => 137.8 [Endpoint 0] 10:21:58.582 SERIAL » [ACK] (0x06) 10:21:58.583 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 137.8 10:22:00.399 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 10:22:00.401 SERIAL » [ACK] (0x06) 10:22:00.403 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 10:22:00.407 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 10:22:00.711 SERIAL « 0x01090004001e033003ff23 (11 bytes) 10:22:00.712 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:22:00.713 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:22:00.714 SERIAL » [ACK] (0x06) 10:22:00.716 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:22:00.744 SERIAL » 0x010e00131f07600d00012501ff256c04 (16 bytes) 10:22:00.745 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 108 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCSet] target value: true 10:22:00.752 SERIAL « [ACK] (0x06) 10:22:00.758 SERIAL « 0x0104011301e8 (6 bytes) 10:22:00.759 SERIAL » [ACK] (0x06) 10:22:00.760 DRIVER « [RES] [SendData] was sent: true 10:22:00.766 SERIAL « 0x01090004001e032001ff31 (11 bytes) 10:22:00.766 SERIAL » [ACK] (0x06) 10:22:00.768 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:22:00.771 CNTRLR [Node 030] treating BasicCC Set as a report 10:22:00.771 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:22:00.810 SERIAL « 0x010700136c00000681 (9 bytes) 10:22:00.811 SERIAL » [ACK] (0x06) 10:22:00.812 DRIVER « [REQ] [SendData] callback id: 108 transmit status: OK 10:22:00.820 SERIAL » 0x010d00131f06600d00012502256dfb (15 bytes) 10:22:00.821 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 109 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 10:22:00.822 SERIAL « [ACK] (0x06) 10:22:00.829 SERIAL « 0x0104011301e8 (6 bytes) 10:22:00.829 SERIAL » [ACK] (0x06) 10:22:00.829 DRIVER « [RES] [SendData] was sent: true 10:22:00.846 SERIAL « 0x010700136d00000385 (9 bytes) 10:22:00.847 SERIAL » [ACK] (0x06) 10:22:00.847 DRIVER « [REQ] [SendData] callback id: 109 transmit status: OK 10:22:00.858 SERIAL « 0x010d0004001f07600d01002503ff5b (15 bytes) 10:22:00.859 CNTRLR [Node 031] [~] [Binary Switch] currentValue: false => true [Endpoint 1] 10:22:00.860 SERIAL » [ACK] (0x06) 10:22:00.861 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: true 10:22:05.581 SERIAL « 0x010c000400030631050422048d69 (14 bytes) 10:22:05.582 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:22:05.582 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 137.8 => 116.5 [Endpoint 0] 10:22:05.583 SERIAL » [ACK] (0x06) 10:22:05.584 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 116.5 10:22:23.598 SERIAL « 0x010900040007033003ff3a (11 bytes) 10:22:23.600 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:22:23.600 CNTRLR [Node 007] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:22:23.601 SERIAL » [ACK] (0x06) 10:22:23.603 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:22:23.820 SERIAL « 0x0110000400070a7105000000ff0708000062 (18 bytes) 10:22:23.821 SERIAL » [ACK] (0x06) 10:22:23.822 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 10:22:23.825 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 10:22:41.293 SERIAL « 0x01090004100b0380034b22 (11 bytes) 10:22:41.294 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 10:22:41.294 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 10:22:41.295 SERIAL » [ACK] (0x06) 10:22:41.297 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 10:22:41.373 SERIAL « 0x01090004100b0380034b22 (11 bytes) 10:22:41.374 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 10:22:41.374 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 10:22:41.375 SERIAL » [ACK] (0x06) 10:22:41.377 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 10:22:41.387 SERIAL « 0x01090004100b0380034b22 (11 bytes) 10:22:41.388 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 10:22:41.389 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 10:22:41.389 SERIAL » [ACK] (0x06) 10:22:41.392 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 10:22:41.424 SERIAL « 0x01090004100b0380034b22 (11 bytes) 10:22:41.424 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 10:22:41.425 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 10:22:41.426 SERIAL » [ACK] (0x06) 10:22:41.428 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 10:22:41.468 SERIAL « 0x01090004100b0380034b22 (11 bytes) 10:22:41.469 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 10:22:41.469 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 10:22:41.470 SERIAL » [ACK] (0x06) 10:22:41.472 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 10:22:41.530 SERIAL « 0x01090004100b0380034b22 (11 bytes) 10:22:41.531 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 10:22:41.531 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 10:22:41.532 SERIAL » [ACK] (0x06) 10:22:41.533 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 10:22:41.576 SERIAL « 0x01090004100b0380034b22 (11 bytes) 10:22:41.577 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 10:22:41.577 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 10:22:41.578 SERIAL » [ACK] (0x06) 10:22:41.579 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 10:22:41.640 SERIAL « 0x010c0004000b0643030142019068 (14 bytes) 10:22:41.642 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpoint[1]: 4 => 4 [Endpoint 0] 10:22:41.643 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 10:22:41.643 SERIAL » [ACK] (0x06) 10:22:41.644 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 4 °C 10:22:41.657 SERIAL « 0x01090004100b0380034b22 (11 bytes) 10:22:41.657 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 10:22:41.658 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 10:22:41.658 SERIAL » [ACK] (0x06) 10:22:41.659 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 10:22:41.750 SERIAL « 0x01090004100b0380034b22 (11 bytes) 10:22:41.751 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 10:22:41.751 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 10:22:41.752 SERIAL » [ACK] (0x06) 10:22:41.753 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 10:22:41.805 SERIAL « 0x010a0004000b044608007fcf (12 bytes) 10:22:41.806 CNTRLR [Node 011] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 10:22:41.807 CNTRLR [Node 011] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 10:22:41.807 SERIAL » [ACK] (0x06) 10:22:41.810 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ClimateControlScheduleCCOverrideReport] override type: None override state: Unused 10:22:41.824 SERIAL « 0x01080004000b02840779 (10 bytes) 10:22:41.825 SERIAL » [ACK] (0x06) 10:22:41.825 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:22:41.826 CNTRLR « [Node 011] received wakeup notification 10:22:41.827 CNTRLR [Node 011] The node is now awake. 10:22:41.828 CNTRLR [Node 011] expects some queries after wake up, so it shall receive 10:22:41.828 CNTRLR [Node 011] compat query "Battery"::get() 10:22:41.833 SERIAL » 0x010900130b028002256e25 (11 bytes) 10:22:41.834 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 110 └─[BatteryCCGet] 10:22:41.835 SERIAL « [ACK] (0x06) 10:22:41.841 SERIAL « 0x0104011301e8 (6 bytes) 10:22:41.842 SERIAL » [ACK] (0x06) 10:22:41.842 DRIVER « [RES] [SendData] was sent: true 10:22:41.869 SERIAL « 0x01090004000b0380034b32 (11 bytes) 10:22:41.870 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 10:22:41.870 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 10:22:41.871 SERIAL » [ACK] (0x06) 10:22:41.872 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 10:22:41.913 SERIAL « 0x010700136e0000088d (9 bytes) 10:22:41.913 SERIAL » [ACK] (0x06) 10:22:41.913 DRIVER « [REQ] [SendData] callback id: 110 transmit status: OK 10:22:41.970 SERIAL « 0x01090004000b0380034b32 (11 bytes) 10:22:41.971 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 10:22:41.971 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 10:22:41.972 SERIAL » [ACK] (0x06) 10:22:41.973 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 10:22:41.977 CNTRLR [Node 011] API call successful 10:22:41.977 CNTRLR [Node 011] compat query "Thermostat Setpoint"::get(1) 10:22:41.981 SERIAL » 0x010a00130b03430201256fe4 (12 bytes) 10:22:41.982 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 111 └─[ThermostatSetpointCCGet] setpoint type: Heating 10:22:41.984 SERIAL « [ACK] (0x06) 10:22:41.989 SERIAL « 0x0104011301e8 (6 bytes) 10:22:41.990 SERIAL » [ACK] (0x06) 10:22:41.990 DRIVER « [RES] [SendData] was sent: true 10:22:42.007 SERIAL « 0x010700136f00000387 (9 bytes) 10:22:42.008 SERIAL » [ACK] (0x06) 10:22:42.008 DRIVER « [REQ] [SendData] callback id: 111 transmit status: OK 10:22:42.019 SERIAL « 0x010c0004000b0643030142019068 (14 bytes) 10:22:42.019 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpoint[1]: 4 => 4 [Endpoint 0] 10:22:42.020 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 10:22:42.020 SERIAL » [ACK] (0x06) 10:22:42.021 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 4 °C 10:22:42.023 CNTRLR [Node 011] API call successful 10:22:43.026 CNTRLR » [Node 011] Sending node back to sleep... 10:22:43.035 SERIAL » 0x010900130b028408257035 (11 bytes) 10:22:43.036 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 112 └─[WakeUpCCNoMoreInformation] 10:22:43.042 SERIAL « [ACK] (0x06) 10:22:43.048 SERIAL « 0x0104011301e8 (6 bytes) 10:22:43.049 SERIAL » [ACK] (0x06) 10:22:43.049 DRIVER « [RES] [SendData] was sent: true 10:22:43.144 SERIAL « 0x010700137000000a91 (9 bytes) 10:22:43.144 SERIAL » [ACK] (0x06) 10:22:43.145 DRIVER « [REQ] [SendData] callback id: 112 transmit status: OK 10:22:43.151 CNTRLR [Node 011] The node is now asleep. 10:22:43.153 CNTRLR [Node 011] Node asleep 10:23:21.521 SERIAL « 0x0108000400080284077a (10 bytes) 10:23:21.522 SERIAL » [ACK] (0x06) 10:23:21.523 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:23:21.525 CNTRLR « [Node 008] received wakeup notification 10:23:21.526 CNTRLR [Node 008] The node is now awake. 10:23:21.738 SERIAL « 0x01090004000703300300c5 (11 bytes) 10:23:21.739 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:23:21.741 CNTRLR [Node 007] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:23:21.742 SERIAL » [ACK] (0x06) 10:23:21.743 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:23:21.964 SERIAL « 0x01080004001e0284076c (10 bytes) 10:23:21.965 SERIAL » [ACK] (0x06) 10:23:21.966 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:23:21.969 CNTRLR « [Node 030] received wakeup notification 10:23:21.970 CNTRLR [Node 030] The node is now awake. 10:23:21.979 SERIAL « 0x0110000400070a7105000000ff070000006a (18 bytes) 10:23:21.980 SERIAL » [ACK] (0x06) 10:23:21.981 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) 10:23:22.020 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 10:23:22.527 CNTRLR » [Node 008] Sending node back to sleep... 10:23:22.532 SERIAL » 0x0109001308028408257137 (11 bytes) 10:23:22.532 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 113 └─[WakeUpCCNoMoreInformation] 10:23:22.534 SERIAL « [ACK] (0x06) 10:23:22.540 SERIAL « 0x0104011301e8 (6 bytes) 10:23:22.540 SERIAL » [ACK] (0x06) 10:23:22.541 DRIVER « [RES] [SendData] was sent: true 10:23:22.619 SERIAL « 0x010700137100000993 (9 bytes) 10:23:22.619 SERIAL » [ACK] (0x06) 10:23:22.619 DRIVER « [REQ] [SendData] callback id: 113 transmit status: OK 10:23:22.624 CNTRLR [Node 008] The node is now asleep. 10:23:22.626 CNTRLR [Node 008] Node asleep 10:23:22.977 CNTRLR » [Node 030] Sending node back to sleep... 10:23:22.986 SERIAL » 0x010900131e028408257222 (11 bytes) 10:23:22.987 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 114 └─[WakeUpCCNoMoreInformation] 10:23:22.989 SERIAL « [ACK] (0x06) 10:23:22.995 SERIAL « 0x0104011301e8 (6 bytes) 10:23:22.995 SERIAL » [ACK] (0x06) 10:23:22.996 DRIVER « [RES] [SendData] was sent: true 10:23:23.013 SERIAL « 0x01070013720000029b (9 bytes) 10:23:23.014 SERIAL » [ACK] (0x06) 10:23:23.015 DRIVER « [REQ] [SendData] callback id: 114 transmit status: OK 10:23:23.025 CNTRLR [Node 030] The node is now asleep. 10:23:23.028 CNTRLR [Node 030] Node asleep 10:23:23.143 SERIAL « 0x010c00040008063105012200ce20 (14 bytes) 10:23:23.144 CNTRLR [Node 008] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 10:23:23.146 CNTRLR [Node 008] [~] [Multilevel Sensor] Air temperature: 20.1 => 20.6 [Endpoint 0] 10:23:23.147 SERIAL » [ACK] (0x06) 10:23:23.149 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 20.6 10:23:31.101 SERIAL « 0x01090004001b03300300d9 (11 bytes) 10:23:31.102 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:23:31.102 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:23:31.103 SERIAL » [ACK] (0x06) 10:23:31.104 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:23:31.156 SERIAL « 0x01090004001b03200100cb (11 bytes) 10:23:31.156 SERIAL » [ACK] (0x06) 10:23:31.157 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 10:23:31.158 CNTRLR [Node 027] treating BasicCC Set as a report 10:23:31.158 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:23:34.869 SERIAL « 0x01090004001e03300300dc (11 bytes) 10:23:34.869 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:23:34.870 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:23:34.870 SERIAL » [ACK] (0x06) 10:23:34.871 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:23:34.923 SERIAL « 0x01090004001e03200100ce (11 bytes) 10:23:34.923 SERIAL » [ACK] (0x06) 10:23:34.924 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 10:23:34.925 CNTRLR [Node 030] treating BasicCC Set as a report 10:23:34.925 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:23:35.868 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 10:23:35.869 SERIAL » [ACK] (0x06) 10:23:35.870 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  10:23:35.873 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 10:24:21.881 SERIAL « 0x0114000400220e600d010032022144000002410000b9 (22 bytes) 10:24:21.883 CNTRLR [Node 034] [~] [Meter] value[65537]: 5.77 => 5.77 [Endpoint 1] 10:24:21.885 CNTRLR [Node 034] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 1] 10:24:21.886 SERIAL » [ACK] (0x06) 10:24:21.888 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 5.77 time delta: 0 seconds 10:24:21.954 SERIAL « 0x0114000400220e600d0200320221440000009300006a (22 bytes) 10:24:21.956 CNTRLR [Node 034] [~] [Meter] value[65537]: 1.47 => 1.47 [Endpoint 2] 10:24:21.957 CNTRLR [Node 034] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 2] 10:24:21.957 SERIAL » [ACK] (0x06) 10:24:21.959 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 1.47 time delta: 0 seconds 10:24:25.878 SERIAL « 0x0112000400220c600d0100320221320000000088 (20 bytes) 10:24:25.880 CNTRLR [Node 034] [~] [Meter] value[66049]: 0 => 0 [Endpoint 1] 10:24:25.881 CNTRLR [Node 034] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 1] 10:24:25.882 SERIAL » [ACK] (0x06) 10:24:25.887 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 10:24:25.951 SERIAL « 0x0112000400220c600d020032022132000000008b (20 bytes) 10:24:25.952 CNTRLR [Node 034] [~] [Meter] value[66049]: 0 => 0 [Endpoint 2] 10:24:25.954 CNTRLR [Node 034] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 2] 10:24:25.955 SERIAL » [ACK] (0x06) 10:24:25.957 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 10:24:28.798 SERIAL « 0x01080004001502840767 (10 bytes) 10:24:28.799 SERIAL » [ACK] (0x06) 10:24:28.800 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:24:28.804 CNTRLR « [Node 021] received wakeup notification 10:24:28.805 CNTRLR [Node 021] The node is now awake. 10:24:29.807 CNTRLR » [Node 021] Sending node back to sleep... 10:24:29.817 SERIAL » 0x0109001315028408257328 (11 bytes) 10:24:29.817 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 115 └─[WakeUpCCNoMoreInformation] 10:24:29.820 SERIAL « [ACK] (0x06) 10:24:29.826 SERIAL « 0x0104011301e8 (6 bytes) 10:24:29.827 SERIAL » [ACK] (0x06) 10:24:29.828 DRIVER « [RES] [SendData] was sent: true 10:24:29.880 SERIAL « 0x01070013730000069e (9 bytes) 10:24:29.881 SERIAL » [ACK] (0x06) 10:24:29.882 DRIVER « [REQ] [SendData] callback id: 115 transmit status: OK 10:24:29.887 CNTRLR [Node 021] The node is now asleep. 10:24:29.891 CNTRLR [Node 021] Node asleep 10:24:30.402 SERIAL « 0x010c00040015063105012200c635 (14 bytes) 10:24:30.404 CNTRLR [Node 021] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 10:24:30.405 CNTRLR [Node 021] [~] [Multilevel Sensor] Air temperature: 18.7 => 19.8 [Endpoint 0] 10:24:30.406 SERIAL » [ACK] (0x06) 10:24:30.408 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 19.8 10:24:34.893 SERIAL » 0x010e00131f07600d00012501002574e3 (16 bytes) 10:24:34.894 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 116 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCSet] target value: false 10:24:34.896 SERIAL « [ACK] (0x06) 10:24:34.903 SERIAL « 0x0104011301e8 (6 bytes) 10:24:34.903 SERIAL » [ACK] (0x06) 10:24:34.904 DRIVER « [RES] [SendData] was sent: true 10:24:34.921 SERIAL « 0x01070013740000029d (9 bytes) 10:24:34.921 SERIAL » [ACK] (0x06) 10:24:34.922 DRIVER « [REQ] [SendData] callback id: 116 transmit status: OK 10:24:34.933 SERIAL » 0x010d00131f06600d000125022575e3 (15 bytes) 10:24:34.934 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 117 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 10:24:34.936 SERIAL « [ACK] (0x06) 10:24:34.942 SERIAL « 0x0104011301e8 (6 bytes) 10:24:34.943 SERIAL » [ACK] (0x06) 10:24:34.944 DRIVER « [RES] [SendData] was sent: true 10:24:34.960 SERIAL « 0x01070013750000029c (9 bytes) 10:24:34.961 SERIAL » [ACK] (0x06) 10:24:34.966 DRIVER « [REQ] [SendData] callback id: 117 transmit status: OK 10:24:34.973 SERIAL « 0x010d0004001f07600d0100250300a4 (15 bytes) 10:24:34.974 CNTRLR [Node 031] [~] [Binary Switch] currentValue: true => false [Endpoint 1] 10:24:34.975 SERIAL » [ACK] (0x06) 10:24:34.977 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: false 10:25:55.696 SERIAL « 0x0110000400230a600d02003105012200c47e (18 bytes) 10:25:55.697 CNTRLR [Node 035] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 10:25:55.699 CNTRLR [Node 035] [~] [Multilevel Sensor] Air temperature: 19.5 => 19.6 [Endpoint 2] 10:25:55.700 SERIAL » [ACK] (0x06) 10:25:55.702 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 19.6 10:26:19.656 SERIAL « 0x01080004001102840763 (10 bytes) 10:26:19.657 SERIAL » [ACK] (0x06) 10:26:19.658 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:26:19.664 CNTRLR « [Node 017] received wakeup notification 10:26:19.665 CNTRLR [Node 017] The node is now awake. 10:26:20.681 CNTRLR » [Node 017] Sending node back to sleep... 10:26:20.690 SERIAL » 0x0109001311028408257629 (11 bytes) 10:26:20.691 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 118 └─[WakeUpCCNoMoreInformation] 10:26:20.693 SERIAL « [ACK] (0x06) 10:26:20.699 SERIAL « 0x0104011301e8 (6 bytes) 10:26:20.699 SERIAL » [ACK] (0x06) 10:26:20.700 DRIVER « [RES] [SendData] was sent: true 10:26:20.717 SERIAL « 0x01070013760000029f (9 bytes) 10:26:20.717 SERIAL » [ACK] (0x06) 10:26:20.720 DRIVER « [REQ] [SendData] callback id: 118 transmit status: OK 10:26:20.733 CNTRLR [Node 017] The node is now asleep. 10:26:20.735 CNTRLR [Node 017] Node asleep 10:27:02.982 SERIAL « 0x01090004001b033003ff26 (11 bytes) 10:27:02.983 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:27:02.984 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:27:02.985 SERIAL » [ACK] (0x06) 10:27:02.987 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:27:03.036 SERIAL « 0x01090004001b032001ff34 (11 bytes) 10:27:03.036 SERIAL » [ACK] (0x06) 10:27:03.037 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:27:03.039 CNTRLR [Node 027] treating BasicCC Set as a report 10:27:03.040 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:27:04.215 SERIAL « 0x01080004102002840742 (10 bytes) 10:27:04.216 SERIAL » [ACK] (0x06) 10:27:04.217 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:27:04.220 CNTRLR « [Node 032] received wakeup notification 10:27:04.221 CNTRLR [Node 032] The node is now awake. 10:27:04.231 SERIAL « 0x01080004102002840742 (10 bytes) 10:27:04.232 SERIAL » [ACK] (0x06) 10:27:04.233 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:27:04.236 CNTRLR « [Node 032] received wakeup notification 10:27:04.243 SERIAL « 0x01080004102002840742 (10 bytes) 10:27:04.244 SERIAL » [ACK] (0x06) 10:27:04.245 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:27:04.247 CNTRLR « [Node 032] received wakeup notification 10:27:04.294 SERIAL « 0x01080004102002840742 (10 bytes) 10:27:04.294 SERIAL » [ACK] (0x06) 10:27:04.295 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:27:04.296 CNTRLR « [Node 032] received wakeup notification 10:27:04.355 SERIAL « 0x01080004102002840742 (10 bytes) 10:27:04.355 SERIAL » [ACK] (0x06) 10:27:04.356 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:27:04.357 CNTRLR « [Node 032] received wakeup notification 10:27:04.577 SERIAL « 0x01080004102002840742 (10 bytes) 10:27:04.577 SERIAL » [ACK] (0x06) 10:27:04.578 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:27:04.580 CNTRLR « [Node 032] received wakeup notification 10:27:04.590 SERIAL « 0x01080004102002840742 (10 bytes) 10:27:04.591 SERIAL » [ACK] (0x06) 10:27:04.592 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:27:04.594 CNTRLR « [Node 032] received wakeup notification 10:27:04.604 SERIAL « 0x01080004102002840742 (10 bytes) 10:27:04.605 SERIAL » [ACK] (0x06) 10:27:04.606 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:27:04.607 CNTRLR « [Node 032] received wakeup notification 10:27:04.662 SERIAL « 0x01080004102002840742 (10 bytes) 10:27:04.663 SERIAL » [ACK] (0x06) 10:27:04.664 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:27:04.666 CNTRLR « [Node 032] received wakeup notification 10:27:04.677 SERIAL « 0x01080004102002840742 (10 bytes) 10:27:04.678 SERIAL » [ACK] (0x06) 10:27:04.679 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:27:04.681 CNTRLR « [Node 032] received wakeup notification 10:27:04.767 SERIAL « 0x01080004102002840742 (10 bytes) 10:27:04.768 SERIAL » [ACK] (0x06) 10:27:04.769 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 10:27:04.772 CNTRLR « [Node 032] received wakeup notification 10:27:05.773 CNTRLR » [Node 032] Sending node back to sleep... 10:27:05.782 SERIAL » 0x0109001320028408257719 (11 bytes) 10:27:05.783 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 119 └─[WakeUpCCNoMoreInformation] 10:27:05.785 SERIAL « [ACK] (0x06) 10:27:05.791 SERIAL « 0x0104011301e8 (6 bytes) 10:27:05.792 SERIAL » [ACK] (0x06) 10:27:05.793 DRIVER « [RES] [SendData] was sent: true 10:27:05.854 SERIAL « 0x01070013770000079b (9 bytes) 10:27:05.854 SERIAL » [ACK] (0x06) 10:27:05.855 DRIVER « [REQ] [SendData] callback id: 119 transmit status: OK 10:27:05.859 CNTRLR [Node 032] The node is now asleep. 10:27:05.860 CNTRLR [Node 032] Node asleep 10:28:07.175 SERIAL « 0x01090004001b03300300d9 (11 bytes) 10:28:07.183 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:28:07.184 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:28:07.185 SERIAL » [ACK] (0x06) 10:28:07.190 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:28:07.227 SERIAL « 0x01090004001b03200100cb (11 bytes) 10:28:07.228 SERIAL » [ACK] (0x06) 10:28:07.229 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 10:28:07.232 CNTRLR [Node 027] treating BasicCC Set as a report 10:28:07.232 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:28:14.807 SERIAL « 0x01090004001b033003ff26 (11 bytes) 10:28:14.808 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:28:14.809 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:28:14.810 SERIAL » [ACK] (0x06) 10:28:14.812 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:28:14.861 SERIAL « 0x01090004001b032001ff34 (11 bytes) 10:28:14.862 SERIAL » [ACK] (0x06) 10:28:14.864 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:28:14.866 CNTRLR [Node 027] treating BasicCC Set as a report 10:28:14.867 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:28:40.399 SERIAL « 0x01090004001e033003ff23 (11 bytes) 10:28:40.399 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:28:40.400 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:28:40.400 SERIAL » [ACK] (0x06) 10:28:40.401 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:28:40.415 SERIAL » 0x010e00131f07600d00012501ff257810 (16 bytes) 10:28:40.415 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 120 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCSet] target value: true 10:28:40.417 SERIAL « [ACK] (0x06) 10:28:40.423 SERIAL « 0x0104011301e8 (6 bytes) 10:28:40.424 SERIAL » [ACK] (0x06) 10:28:40.424 DRIVER « [RES] [SendData] was sent: true 10:28:40.483 SERIAL « 0x010700137800000695 (9 bytes) 10:28:40.484 SERIAL » [ACK] (0x06) 10:28:40.484 DRIVER « [REQ] [SendData] callback id: 120 transmit status: OK 10:28:40.491 SERIAL » 0x010d00131f06600d000125022579ef (15 bytes) 10:28:40.491 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 121 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 10:28:40.493 SERIAL « [ACK] (0x06) 10:28:40.500 SERIAL « 0x0104011301e8 (6 bytes) 10:28:40.500 SERIAL » [ACK] (0x06) 10:28:40.500 DRIVER « [RES] [SendData] was sent: true 10:28:40.518 SERIAL « 0x010700137900000391 (9 bytes) 10:28:40.518 SERIAL » [ACK] (0x06) 10:28:40.518 DRIVER « [REQ] [SendData] callback id: 121 transmit status: OK 10:28:40.529 SERIAL « 0x010d0004001f07600d01002503ff5b (15 bytes) 10:28:40.530 CNTRLR [Node 031] [~] [Binary Switch] currentValue: false => true [Endpoint 1] 10:28:40.530 SERIAL » [ACK] (0x06) 10:28:40.531 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: true 10:28:40.738 SERIAL « 0x01090004001e032001ff31 (11 bytes) 10:28:40.739 SERIAL » [ACK] (0x06) 10:28:40.741 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:28:40.742 CNTRLR [Node 030] treating BasicCC Set as a report 10:28:40.743 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:28:41.337 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 10:28:41.337 SERIAL » [ACK] (0x06) 10:28:41.339 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 10:28:41.341 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 10:28:49.346 SERIAL « 0x010900040015033003ff28 (11 bytes) 10:28:49.347 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:28:49.348 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:28:49.348 SERIAL » [ACK] (0x06) 10:28:49.350 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:28:49.400 SERIAL « 0x010900040015032001ff3a (11 bytes) 10:28:49.401 SERIAL » [ACK] (0x06) 10:28:49.402 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:28:49.404 CNTRLR [Node 021] treating BasicCC Set as a report 10:28:49.404 CNTRLR [Node 021] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:29:05.400 SERIAL « 0x01090004001b03300300d9 (11 bytes) 10:29:05.401 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:29:05.402 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:29:05.403 SERIAL » [ACK] (0x06) 10:29:05.405 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:29:05.454 SERIAL « 0x01090004001b03200100cb (11 bytes) 10:29:05.455 SERIAL » [ACK] (0x06) 10:29:05.456 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 10:29:05.459 CNTRLR [Node 027] treating BasicCC Set as a report 10:29:05.459 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:29:10.326 SERIAL « 0x01090004001e03300300dc (11 bytes) 10:29:10.328 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:29:10.329 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:29:10.330 SERIAL » [ACK] (0x06) 10:29:10.332 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:29:10.381 SERIAL « 0x01090004001e03200100ce (11 bytes) 10:29:10.382 SERIAL » [ACK] (0x06) 10:29:10.383 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 10:29:10.407 CNTRLR [Node 030] treating BasicCC Set as a report 10:29:10.407 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:29:12.429 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 10:29:12.429 SERIAL » [ACK] (0x06) 10:29:12.431 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  10:29:12.434 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 10:29:13.994 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 10:29:13.994 SERIAL » [ACK] (0x06) 10:29:13.995 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 10:29:13.996 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 10:29:17.248 SERIAL « 0x01090004001e033003ff23 (11 bytes) 10:29:17.250 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:29:17.251 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:29:17.252 SERIAL » [ACK] (0x06) 10:29:17.254 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:29:17.303 SERIAL « 0x01090004001e032001ff31 (11 bytes) 10:29:17.303 SERIAL » [ACK] (0x06) 10:29:17.304 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:29:17.312 CNTRLR [Node 030] treating BasicCC Set as a report 10:29:17.313 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:29:19.997 SERIAL « 0x01090004001b033003ff26 (11 bytes) 10:29:19.998 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:29:19.999 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:29:20.000 SERIAL » [ACK] (0x06) 10:29:20.001 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:29:20.054 SERIAL « 0x01090004001b032001ff34 (11 bytes) 10:29:20.054 SERIAL » [ACK] (0x06) 10:29:20.055 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:29:20.057 CNTRLR [Node 027] treating BasicCC Set as a report 10:29:20.058 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:29:28.397 SERIAL « 0x010900040007033003ff3a (11 bytes) 10:29:28.397 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:29:28.398 CNTRLR [Node 007] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:29:28.398 SERIAL » [ACK] (0x06) 10:29:28.399 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:29:28.619 SERIAL « 0x0110000400070a7105000000ff0708000062 (18 bytes) 10:29:28.619 SERIAL » [ACK] (0x06) 10:29:28.620 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 10:29:28.621 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 10:29:35.478 SERIAL « 0x01090004001503300300d7 (11 bytes) 10:29:35.479 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:29:35.480 CNTRLR [Node 021] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:29:35.481 SERIAL » [ACK] (0x06) 10:29:35.482 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:29:35.533 SERIAL « 0x01090004001503200100c5 (11 bytes) 10:29:35.533 SERIAL » [ACK] (0x06) 10:29:35.534 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 10:29:35.536 CNTRLR [Node 021] treating BasicCC Set as a report 10:29:35.536 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:29:50.579 SERIAL « 0x01090004001b03300300d9 (11 bytes) 10:29:50.579 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:29:50.580 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:29:50.580 SERIAL » [ACK] (0x06) 10:29:50.581 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:29:50.636 SERIAL « 0x01090004001b03200100cb (11 bytes) 10:29:50.636 SERIAL » [ACK] (0x06) 10:29:50.637 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 10:29:50.638 CNTRLR [Node 027] treating BasicCC Set as a report 10:29:50.638 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:29:50.776 SERIAL « 0x010900040015033003ff28 (11 bytes) 10:29:50.777 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:29:50.777 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:29:50.778 SERIAL » [ACK] (0x06) 10:29:50.780 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:29:50.830 SERIAL « 0x010900040015032001ff3a (11 bytes) 10:29:50.830 SERIAL » [ACK] (0x06) 10:29:50.831 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:29:50.832 CNTRLR [Node 021] treating BasicCC Set as a report 10:29:50.833 CNTRLR [Node 021] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:29:56.373 SERIAL » 0x011000131609600d0001430101010a257a98 (18 bytes) 10:29:56.377 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 122 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCSet] setpoint type: Heating value: 10 °C 10:29:56.379 SERIAL « [ACK] (0x06) 10:29:56.386 SERIAL « 0x0104011301e8 (6 bytes) 10:29:56.386 SERIAL » [ACK] (0x06) 10:29:56.387 DRIVER « [RES] [SendData] was sent: true 10:29:57.765 SERIAL « 0x010700137a00008a1b (9 bytes) 10:29:57.766 SERIAL » [ACK] (0x06) 10:29:57.766 DRIVER « [REQ] [SendData] callback id: 122 transmit status: OK 10:29:57.777 SERIAL » 0x010e00131607600d0001430201257b81 (16 bytes) 10:29:57.778 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 123 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 10:29:57.780 SERIAL « [ACK] (0x06) 10:29:57.786 SERIAL « 0x0104011301e8 (6 bytes) 10:29:57.787 SERIAL » [ACK] (0x06) 10:29:57.787 DRIVER « [RES] [SendData] was sent: true 10:29:57.846 SERIAL « 0x010700137b00000696 (9 bytes) 10:29:57.847 SERIAL » [ACK] (0x06) 10:29:57.847 DRIVER « [REQ] [SendData] callback id: 123 transmit status: OK 10:29:57.933 SERIAL « 0x010a000400160422010102c3 (12 bytes) 10:29:57.935 DRIVER Dropping message because it could not be deserialized: The command class Appli cation Status is not implemented 10:29:57.936 SERIAL » [ACK] (0x06) 10:29:58.637 SERIAL « 0x01090004000703300300c5 (11 bytes) 10:29:58.637 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:29:58.638 CNTRLR [Node 007] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:29:58.638 SERIAL » [ACK] (0x06) 10:29:58.639 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:29:58.859 SERIAL « 0x0110000400070a7105000000ff070000006a (18 bytes) 10:29:58.860 SERIAL » [ACK] (0x06) 10:29:58.861 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) 10:29:58.899 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 10:29:59.452 CNTRLR [Node 022] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 10:29:59.958 SERIAL » 0x010e00131607600d0001430201257b81 (16 bytes) 10:29:59.959 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 123 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 10:29:59.961 SERIAL « [ACK] (0x06) 10:29:59.968 SERIAL « 0x0104011301e8 (6 bytes) 10:29:59.968 SERIAL » [ACK] (0x06) 10:29:59.969 DRIVER « [RES] [SendData] was sent: true 10:30:01.327 SERIAL « 0x010c0004100d06310504220000fe (14 bytes) 10:30:01.329 CNTRLR [Node 013] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:30:01.330 CNTRLR [Node 013] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 10:30:01.331 SERIAL » [ACK] (0x06) 10:30:01.333 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 10:30:01.863 SERIAL « 0x010c0004100e06310504220000fd (14 bytes) 10:30:01.864 CNTRLR [Node 014] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:30:01.866 CNTRLR [Node 014] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 10:30:01.867 SERIAL » [ACK] (0x06) 10:30:01.869 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 10:30:02.515 SERIAL « 0x010c0004100d06310504220000fe (14 bytes) 10:30:02.516 CNTRLR [Node 013] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:30:02.516 CNTRLR [Node 013] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 10:30:02.517 SERIAL » [ACK] (0x06) 10:30:02.518 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 10:30:02.527 SERIAL « 0x010c0004100d06310504220000fe (14 bytes) 10:30:02.527 CNTRLR [Node 013] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:30:02.528 CNTRLR [Node 013] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 10:30:02.529 SERIAL » [ACK] (0x06) 10:30:02.530 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 10:30:02.549 SERIAL « 0x010700137b00010392 (9 bytes) 10:30:02.549 SERIAL » [ACK] (0x06) 10:30:02.550 DRIVER « [REQ] [SendData] callback id: 123 transmit status: OK 10:30:02.644 SERIAL « 0x0110000400160a600d01004303012200649c (18 bytes) 10:30:02.645 CNTRLR [Node 022] [~] [Thermostat Setpoint] setpoint[1]: 21 => 10 [Endpoint 1] 10:30:02.646 CNTRLR [Node 022] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 10:30:02.646 SERIAL » [ACK] (0x06) 10:30:02.647 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 10:30:03.626 SERIAL « 0x010c0004000f06310504220000ec (14 bytes) 10:30:03.628 CNTRLR [Node 015] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:30:03.629 CNTRLR [Node 015] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 10:30:03.630 SERIAL » [ACK] (0x06) 10:30:03.632 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 10:30:05.530 SERIAL « 0x01100004000d0a32022144000000cf000076 (18 bytes) 10:30:05.531 CNTRLR [Node 013] [~] [Meter] value[65537]: 2.07 => 2.07 [Endpoint 0] 10:30:05.532 CNTRLR [Node 013] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 10:30:05.533 SERIAL » [ACK] (0x06) 10:30:05.534 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 2.07 time delta: 0 seconds 10:30:05.691 SERIAL « 0x01100004000d0a32022144000000cf000076 (18 bytes) 10:30:05.693 CNTRLR [Node 013] [~] [Meter] value[65537]: 2.07 => 2.07 [Endpoint 0] 10:30:05.694 CNTRLR [Node 013] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 10:30:05.694 SERIAL » [ACK] (0x06) 10:30:05.696 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 2.07 time delta: 0 seconds 10:30:06.319 SERIAL « 0x01100004000e0a320221440000013000008b (18 bytes) 10:30:06.320 CNTRLR [Node 014] [~] [Meter] value[65537]: 3.04 => 3.04 [Endpoint 0] 10:30:06.321 CNTRLR [Node 014] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 10:30:06.322 SERIAL » [ACK] (0x06) 10:30:06.324 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 3.04 time delta: 0 seconds 10:30:08.464 SERIAL « 0x010c0004001006310504220000f3 (14 bytes) 10:30:08.464 CNTRLR [Node 016] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:30:08.465 CNTRLR [Node 016] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 10:30:08.466 SERIAL » [ACK] (0x06) 10:30:08.467 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 10:30:08.822 SERIAL « 0x010c0004000c06310504220000ef (14 bytes) 10:30:08.822 CNTRLR [Node 012] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:30:08.823 CNTRLR [Node 012] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 10:30:08.823 SERIAL » [ACK] (0x06) 10:30:08.825 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 10:30:10.825 SERIAL « 0x01100004000c0a32022144000000c9000071 (18 bytes) 10:30:10.827 CNTRLR [Node 012] [~] [Meter] value[65537]: 2.01 => 2.01 [Endpoint 0] 10:30:10.828 CNTRLR [Node 012] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 10:30:10.829 SERIAL » [ACK] (0x06) 10:30:10.831 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 2.01 time delta: 0 seconds 10:30:12.055 SERIAL « 0x01090004001e03300300dc (11 bytes) 10:30:12.056 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:30:12.057 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:30:12.058 SERIAL » [ACK] (0x06) 10:30:12.060 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:30:12.110 SERIAL « 0x01090004001e03200100ce (11 bytes) 10:30:12.111 SERIAL » [ACK] (0x06) 10:30:12.112 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 10:30:12.124 CNTRLR [Node 030] treating BasicCC Set as a report 10:30:12.124 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:30:13.264 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 10:30:13.265 SERIAL » [ACK] (0x06) 10:30:13.267 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  10:30:13.269 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 10:30:18.466 SERIAL « 0x0110000400100a320221440000014c0000e9 (18 bytes) 10:30:18.467 CNTRLR [Node 016] [~] [Meter] value[65537]: 3.32 => 3.32 [Endpoint 0] 10:30:18.468 CNTRLR [Node 016] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 10:30:18.469 SERIAL » [ACK] (0x06) 10:30:18.471 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 3.32 time delta: 0 seconds 10:30:21.952 SERIAL « 0x010900040008033003ff35 (11 bytes) 10:30:21.953 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:30:21.954 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:30:21.954 SERIAL » [ACK] (0x06) 10:30:21.959 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:30:22.006 SERIAL « 0x010900040008032001ff27 (11 bytes) 10:30:22.006 SERIAL » [ACK] (0x06) 10:30:22.007 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:30:22.008 CNTRLR [Node 008] treating BasicCC Set as a report 10:30:22.008 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:30:38.013 SERIAL « 0x01090004001503300300d7 (11 bytes) 10:30:38.014 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:30:38.026 CNTRLR [Node 021] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:30:38.027 SERIAL » [ACK] (0x06) 10:30:38.029 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:30:38.067 SERIAL « 0x01090004001503200100c5 (11 bytes) 10:30:38.068 SERIAL » [ACK] (0x06) 10:30:38.069 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 10:30:38.071 CNTRLR [Node 021] treating BasicCC Set as a report 10:30:38.072 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:30:38.634 SERIAL « 0x010c000400030631050422085cb4 (14 bytes) 10:30:38.635 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:30:38.636 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 116.5 => 214 [Endpoint 0] 10:30:38.636 SERIAL » [ACK] (0x06) 10:30:38.637 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 214 10:30:39.634 SERIAL « 0x010c00040003063105042206ed0b (14 bytes) 10:30:39.634 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:30:39.635 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 214 => 177.3 [Endpoint 0] 10:30:39.635 SERIAL » [ACK] (0x06) 10:30:39.636 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 177.3 10:30:40.634 SERIAL « 0x010c00040003063105042203fa19 (14 bytes) 10:30:40.635 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:30:40.636 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 177.3 => 101.8 [Endpoint 0] 10:30:40.637 SERIAL » [ACK] (0x06) 10:30:40.639 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 101.8 10:30:42.634 SERIAL « 0x010c000400030631050422049470 (14 bytes) 10:30:42.636 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:30:42.637 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 101.8 => 117.2 [Endpoint 0] 10:30:42.638 SERIAL » [ACK] (0x06) 10:30:42.639 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 117.2 10:30:46.635 SERIAL « 0x010c000400030631050422090be2 (14 bytes) 10:30:46.635 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:30:46.636 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 117.2 => 231.5 [Endpoint 0] 10:30:46.637 SERIAL » [ACK] (0x06) 10:30:46.639 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 231.5 10:30:53.569 SERIAL « 0x0110000400160a600d02003105012200c44b (18 bytes) 10:30:53.571 CNTRLR [Node 022] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 10:30:53.572 CNTRLR [Node 022] [~] [Multilevel Sensor] Air temperature: 17.9 => 19.6 [Endpoint 2] 10:30:53.573 SERIAL » [ACK] (0x06) 10:30:53.574 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 19.6 10:30:56.636 SERIAL « 0x010c00040003063105042204f511 (14 bytes) 10:30:56.637 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:30:56.638 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 231.5 => 126.9 [Endpoint 0] 10:30:56.639 SERIAL » [ACK] (0x06) 10:30:56.641 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 126.9 10:30:57.883 SERIAL « 0x0110000400160a600d02003105012200ba35 (18 bytes) 10:30:57.884 CNTRLR [Node 022] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 10:30:57.885 CNTRLR [Node 022] [~] [Multilevel Sensor] Air temperature: 19.6 => 18.6 [Endpoint 2] 10:30:57.886 SERIAL » [ACK] (0x06) 10:30:57.888 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.6 10:31:01.635 SERIAL « 0x01090004000803300300ca (11 bytes) 10:31:01.636 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:31:01.637 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:31:01.637 SERIAL » [ACK] (0x06) 10:31:01.638 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:31:01.690 SERIAL « 0x01090004000803200100d8 (11 bytes) 10:31:01.690 SERIAL » [ACK] (0x06) 10:31:01.691 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 10:31:01.693 CNTRLR [Node 008] treating BasicCC Set as a report 10:31:01.693 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:31:03.637 SERIAL « 0x010c000400030631050422086a82 (14 bytes) 10:31:03.638 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:31:03.639 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 126.9 => 215.4 [Endpoint 0] 10:31:03.640 SERIAL » [ACK] (0x06) 10:31:03.642 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 215.4 10:31:04.636 SERIAL « 0x010c000400030631050422049c78 (14 bytes) 10:31:04.637 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:31:04.638 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 215.4 => 118 [Endpoint 0] 10:31:04.638 SERIAL » [ACK] (0x06) 10:31:04.639 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 118 10:31:12.089 SERIAL » 0x010e00131f07600d0001250100257ceb (16 bytes) 10:31:12.090 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 124 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCSet] target value: false 10:31:12.093 SERIAL « [ACK] (0x06) 10:31:12.099 SERIAL « 0x0104011301e8 (6 bytes) 10:31:12.100 SERIAL » [ACK] (0x06) 10:31:12.101 DRIVER « [RES] [SendData] was sent: true 10:31:12.117 SERIAL « 0x010700137c00000394 (9 bytes) 10:31:12.118 SERIAL » [ACK] (0x06) 10:31:12.119 DRIVER « [REQ] [SendData] callback id: 124 transmit status: OK 10:31:12.132 SERIAL » 0x010d00131f06600d00012502257deb (15 bytes) 10:31:12.133 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 125 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 10:31:12.135 SERIAL « [ACK] (0x06) 10:31:12.141 SERIAL « 0x0104011301e8 (6 bytes) 10:31:12.142 SERIAL » [ACK] (0x06) 10:31:12.143 DRIVER « [RES] [SendData] was sent: true 10:31:12.159 SERIAL « 0x010700137d00000395 (9 bytes) 10:31:12.160 SERIAL » [ACK] (0x06) 10:31:12.161 DRIVER « [REQ] [SendData] callback id: 125 transmit status: OK 10:31:12.171 SERIAL « 0x010d0004001f07600d0100250300a4 (15 bytes) 10:31:12.173 CNTRLR [Node 031] [~] [Binary Switch] currentValue: true => false [Endpoint 1] 10:31:12.173 SERIAL » [ACK] (0x06) 10:31:12.175 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: false 10:31:12.637 SERIAL « 0x010c000400030631050422085fb7 (14 bytes) 10:31:12.638 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:31:12.639 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 118 => 214.3 [Endpoint 0] 10:31:12.639 SERIAL » [ACK] (0x06) 10:31:12.640 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 214.3 10:31:15.638 SERIAL « 0x010c0004000306310504220429cd (14 bytes) 10:31:15.639 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:31:15.640 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 214.3 => 106.5 [Endpoint 0] 10:31:15.641 SERIAL » [ACK] (0x06) 10:31:15.643 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 106.5 10:31:29.639 SERIAL « 0x010c00040003063105042208e901 (14 bytes) 10:31:29.641 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:31:29.642 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 106.5 => 228.1 [Endpoint 0] 10:31:29.643 SERIAL » [ACK] (0x06) 10:31:29.645 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 228.1 10:31:31.640 SERIAL « 0x010c0004000306310504220421c5 (14 bytes) 10:31:31.641 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:31:31.641 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 228.1 => 105.7 [Endpoint 0] 10:31:31.642 SERIAL » [ACK] (0x06) 10:31:31.644 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 105.7 10:31:33.639 SERIAL « 0x010c00040003063105042204f216 (14 bytes) 10:31:33.640 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:31:33.641 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 105.7 => 126.6 [Endpoint 0] 10:31:33.642 SERIAL » [ACK] (0x06) 10:31:33.644 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 126.6 10:31:34.277 SERIAL » 0x011000131209600d0001430101011c257e8e (18 bytes) 10:31:34.278 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 126 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCSet] setpoint type: Heating value: 28 °C 10:31:34.280 SERIAL « [ACK] (0x06) 10:31:34.291 SERIAL « 0x0104011301e8 (6 bytes) 10:31:34.292 SERIAL » [ACK] (0x06) 10:31:34.293 DRIVER « [RES] [SendData] was sent: true 10:31:34.337 SERIAL « 0x010700137e00000590 (9 bytes) 10:31:34.338 SERIAL » [ACK] (0x06) 10:31:34.339 DRIVER « [REQ] [SendData] callback id: 126 transmit status: OK 10:31:34.347 SERIAL » 0x010e00131207600d0001430201257f81 (16 bytes) 10:31:34.347 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 127 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 10:31:34.349 SERIAL « [ACK] (0x06) 10:31:34.355 SERIAL « 0x0104011301e8 (6 bytes) 10:31:34.356 SERIAL » [ACK] (0x06) 10:31:34.357 DRIVER « [RES] [SendData] was sent: true 10:31:34.414 SERIAL « 0x010700137f00000692 (9 bytes) 10:31:34.414 SERIAL » [ACK] (0x06) 10:31:34.415 DRIVER « [REQ] [SendData] callback id: 127 transmit status: OK 10:31:34.488 SERIAL « 0x010a000400120422010102c7 (12 bytes) 10:31:34.488 DRIVER Dropping message because it could not be deserialized: The command class Appli cation Status is not implemented 10:31:34.489 SERIAL » [ACK] (0x06) 10:31:34.639 SERIAL « 0x010c000400030631050422091ff6 (14 bytes) 10:31:34.641 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:31:34.642 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 126.6 => 233.5 [Endpoint 0] 10:31:34.643 SERIAL » [ACK] (0x06) 10:31:34.646 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 233.5 10:31:35.639 SERIAL « 0x010c00040003063105042204e206 (14 bytes) 10:31:35.640 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:31:35.640 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 233.5 => 125 [Endpoint 0] 10:31:35.641 SERIAL » [ACK] (0x06) 10:31:35.642 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 125 10:31:36.019 CNTRLR [Node 018] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 10:31:36.524 SERIAL » 0x010e00131207600d0001430201257f81 (16 bytes) 10:31:36.525 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 127 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 10:31:36.527 SERIAL « [ACK] (0x06) 10:31:36.534 SERIAL « 0x0104011301e8 (6 bytes) 10:31:36.534 SERIAL » [ACK] (0x06) 10:31:36.535 DRIVER « [RES] [SendData] was sent: true 10:31:36.584 SERIAL « 0x010700137f00000591 (9 bytes) 10:31:36.584 SERIAL » [ACK] (0x06) 10:31:36.585 DRIVER « [REQ] [SendData] callback id: 127 transmit status: OK 10:31:38.190 CNTRLR [Node 018] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 10:31:38.696 SERIAL » 0x010e00131207600d0001430201257f81 (16 bytes) 10:31:38.697 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 127 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 10:31:38.699 SERIAL « [ACK] (0x06) 10:31:38.706 SERIAL « 0x0104011301e8 (6 bytes) 10:31:38.706 SERIAL » [ACK] (0x06) 10:31:38.707 DRIVER « [RES] [SendData] was sent: true 10:31:38.756 SERIAL « 0x010700137f00000591 (9 bytes) 10:31:38.756 SERIAL » [ACK] (0x06) 10:31:38.757 DRIVER « [REQ] [SendData] callback id: 127 transmit status: OK 10:31:41.537 SERIAL « 0x010900040008033003ff35 (11 bytes) 10:31:41.538 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:31:41.540 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => true [Endpoint 0] 10:31:41.540 SERIAL » [ACK] (0x06) 10:31:41.542 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 10:31:41.592 SERIAL « 0x010900040008032001ff27 (11 bytes) 10:31:41.592 SERIAL » [ACK] (0x06) 10:31:41.593 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 10:31:41.596 CNTRLR [Node 008] treating BasicCC Set as a report 10:31:41.596 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => true [Endpoint 0] 10:31:42.640 SERIAL « 0x010c00040003063105042208ff17 (14 bytes) 10:31:42.642 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:31:42.643 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 125 => 230.3 [Endpoint 0] 10:31:42.644 SERIAL » [ACK] (0x06) 10:31:42.645 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 230.3 10:32:02.643 SERIAL « 0x010c000400030631050422046f8b (14 bytes) 10:32:02.644 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:32:02.645 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 230.3 => 113.5 [Endpoint 0] 10:32:02.646 SERIAL » [ACK] (0x06) 10:32:02.648 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 113.5 10:32:03.643 SERIAL « 0x010c000400030631050422076d8a (14 bytes) 10:32:03.644 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:32:03.645 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 113.5 => 190.1 [Endpoint 0] 10:32:03.646 SERIAL » [ACK] (0x06) 10:32:03.648 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 190.1 10:32:05.643 SERIAL « 0x010c00040003063105042203a744 (14 bytes) 10:32:05.644 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:32:05.645 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 190.1 => 93.5 [Endpoint 0] 10:32:05.646 SERIAL » [ACK] (0x06) 10:32:05.648 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 93.5 10:32:06.643 SERIAL « 0x010c00040003063105042204a347 (14 bytes) 10:32:06.643 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:32:06.644 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 93.5 => 118.7 [Endpoint 0] 10:32:06.644 SERIAL » [ACK] (0x06) 10:32:06.645 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 118.7 10:32:12.205 SERIAL « 0x01090004000803300300ca (11 bytes) 10:32:12.206 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 10:32:12.208 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => false [Endpoint 0] 10:32:12.208 SERIAL » [ACK] (0x06) 10:32:12.210 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 10:32:12.259 SERIAL « 0x01090004000803200100d8 (11 bytes) 10:32:12.260 SERIAL » [ACK] (0x06) 10:32:12.261 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 10:32:12.263 CNTRLR [Node 008] treating BasicCC Set as a report 10:32:12.263 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 10:32:12.643 SERIAL « 0x010c00040003063105042208d931 (14 bytes) 10:32:12.644 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:32:12.645 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 118.7 => 226.5 [Endpoint 0] 10:32:12.646 SERIAL » [ACK] (0x06) 10:32:12.647 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 226.5 10:32:14.220 SERIAL « 0x010c0004001306310504220000f0 (14 bytes) 10:32:14.221 CNTRLR [Node 019] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 10:32:14.223 CNTRLR [Node 019] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 10:32:14.224 SERIAL » [ACK] (0x06) 10:32:14.225 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 10:32:22.222 SERIAL « 0x0110000400130a320221440000010a0000ac (18 bytes) 10:32:22.224 CNTRLR [Node 019] [~] [Meter] value[65537]: 2.66 => 2.66 [Endpoint 0] 10:32:22.225 CNTRLR [Node 019] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 10:32:22.226 SERIAL » [ACK] (0x06) 10:32:22.228 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 2.66 time delta: 0 seconds