20:29:21.624 DRIVER ███████╗ ██╗ ██╗ █████╗ ██╗ ██╗ ███████╗ ██╗ ███████╗ ╚══███╔╝ ██║ ██║ ██╔══██╗ ██║ ██║ ██╔════╝ ██║ ██╔════╝ ███╔╝ ██║ █╗ ██║ ███████║ ██║ ██║ █████╗ █████╗ ██║ ███████╗ ███╔╝ ██║███╗██║ ██╔══██║ ╚██╗ ██╔╝ ██╔══╝ ╚════╝ ██ ██║ ╚════██║ ███████╗ ╚███╔███╔╝ ██║ ██║ ╚████╔╝ ███████╗ ╚█████╔╝ ███████║ ╚══════╝ ╚══╝╚══╝ ╚═╝ ╚═╝ ╚═══╝ ╚══════╝ ╚════╝ ╚══════╝ 20:29:21.626 DRIVER version 5.3.1 20:29:21.626 DRIVER 20:29:21.626 DRIVER starting driver... 20:29:21.635 DRIVER opening serial port /dev/ttyACM0 20:29:21.652 DRIVER serial port opened 20:29:21.653 SERIAL » [NAK] (0x15) 20:29:21.660 SERIAL « 0x010c0004001a063105042208dc2d (14 bytes) 20:29:21.662 DRIVER Dropping message because the driver is not ready to handle it yet. 20:29:21.662 SERIAL » [ACK] (0x06) 20:29:21.664 SERIAL « 0x010c0004001a06310504220c7f8a (14 bytes) 20:29:21.665 DRIVER Dropping message because the driver is not ready to handle it yet. 20:29:21.665 SERIAL » [ACK] (0x06) 20:29:21.962 SERIAL « 0x010c0004001a0631050422093fcf (14 bytes) 20:29:21.963 DRIVER Dropping message because the driver is not ready to handle it yet. 20:29:21.964 SERIAL » [ACK] (0x06) 20:29:23.157 DRIVER loading configuration... 20:29:23.333 DRIVER beginning interview... 20:29:23.334 DRIVER added request handler for AddNodeToNetwork (0x4a)... 1 registered 20:29:23.334 DRIVER added request handler for RemoveNodeFromNetwork (0x4b)... 1 registered 20:29:23.335 CNTRLR beginning interview... 20:29:23.335 CNTRLR querying version info... 20:29:23.416 SERIAL » 0x01030015e9 (5 bytes) 20:29:23.417 DRIVER » [REQ] [GetControllerVersion] 20:29:23.419 SERIAL « [ACK] (0x06) 20:29:23.420 SERIAL « 0x011001155a2d5761766520342e3534000193 (18 bytes) 20:29:23.420 SERIAL » [ACK] (0x06) 20:29:23.421 DRIVER « [RES] [GetControllerVersion] payload: 0x5a2d5761766520342e35340001 20:29:23.424 CNTRLR received version info: controller type: Static Controller library version: Z-Wave 4.54 20:29:23.424 CNTRLR querying controller IDs... 20:29:23.427 SERIAL » 0x01030020dc (5 bytes) 20:29:23.427 DRIVER » [REQ] [GetControllerId] 20:29:23.428 SERIAL « [ACK] (0x06) 20:29:23.429 SERIAL « 0x01080120e371976e01bc (10 bytes) 20:29:23.430 SERIAL » [ACK] (0x06) 20:29:23.430 DRIVER « [RES] [GetControllerId] payload: 0xe371976e01 20:29:23.432 CNTRLR received controller IDs: home ID: 0xe371976e own node ID: 1 20:29:23.432 CNTRLR querying controller capabilities... 20:29:23.435 SERIAL » 0x01030005f9 (5 bytes) 20:29:23.435 DRIVER » [REQ] [GetControllerCapabilities] 20:29:23.436 SERIAL « [ACK] (0x06) 20:29:23.437 SERIAL « 0x010401051ce3 (6 bytes) 20:29:23.437 SERIAL » [ACK] (0x06) 20:29:23.437 DRIVER « [RES] [GetControllerCapabilities] payload: 0x1c 20:29:23.439 CNTRLR received controller capabilities: controller role: primary is in other network: false is SIS present: true was real primary: true is a SUC: true 20:29:23.439 CNTRLR querying API capabilities... 20:29:23.442 SERIAL » 0x01030007fb (5 bytes) 20:29:23.442 DRIVER » [REQ] [GetSerialApiCapabilities] 20:29:23.443 SERIAL « [ACK] (0x06) 20:29:23.444 SERIAL « 0x012b0107010100860001005afe81ff884f1f0000fb9f7da067000080008086000 (45 bytes) 000e87300000e0000600000fa 20:29:23.445 SERIAL » [ACK] (0x06) 20:29:23.445 DRIVER « [RES] [GetSerialApiCapabilities] payload: 0x010100860001005afe81ff884f1f0000fb9f7da067000080008086000000e8730 0000e0000600000 20:29:23.447 CNTRLR received API capabilities: serial API version: 1.1 manufacturer ID: 0x86 product type: 0x01 product ID: 0x5a supported functions: · GetSerialApiInitData (0x02) · FUNC_ID_SERIAL_API_APPL_NODE_INFORMATION (0x03) · ApplicationCommand (0x04) · GetControllerCapabilities (0x05) · SetSerialApiTimeouts (0x06) · GetSerialApiCapabilities (0x07) · FUNC_ID_SERIAL_API_SOFT_RESET (0x08) · UNKNOWN_FUNC_UNKNOWN_0x09 (0x09) · UNKNOWN_FUNC_RF_RECEIVE_MODE (0x10) · UNKNOWN_FUNC_SET_SLEEP_MODE (0x11) · FUNC_ID_ZW_SEND_NODE_INFORMATION (0x12) · SendData (0x13) · SendDataMulticast (0x14) · GetControllerVersion (0x15) · SendDataAbort (0x16) · FUNC_ID_ZW_R_F_POWER_LEVEL_SET (0x17) · UNKNOWN_FUNC_SEND_DATA_META (0x18) · FUNC_ID_ZW_GET_RANDOM (0x1c) · GetControllerId (0x20) · UNKNOWN_FUNC_MEMORY_GET_BYTE (0x21) · UNKNOWN_FUNC_MEMORY_PUT_BYTE (0x22) · UNKNOWN_FUNC_MEMORY_GET_BUFFER (0x23) · UNKNOWN_FUNC_MEMORY_PUT_BUFFER (0x24) · UNKNOWN_FUNC_FlashAutoProgSet (0x27) · UNKNOWN_FUNC_NVMGetId (0x29) · UNKNOWN_FUNC_NVMExtReadLongBuffer (0x2a) · UNKNOWN_FUNC_NVMExtWriteLongBuffer (0x2b) · UNKNOWN_FUNC_NVMExtReadLongByte (0x2c) · UNKNOWN_FUNC_NVMExtWriteLongByte (0x2d) · GetNodeProtocolInfo (0x41) · HardReset (0x42) · FUNC_ID_ZW_REPLICATION_COMMAND_COMPLETE (0x44) · FUNC_ID_ZW_REPLICATION_SEND_DATA (0x45) · AssignReturnRoute (0x46) · DeleteReturnRoute (0x47) · RequestNodeNeighborUpdate (0x48) · ApplicationUpdateRequest (0x49) · AddNodeToNetwork (0x4a) · RemoveNodeFromNetwork (0x4b) · FUNC_ID_ZW_CREATE_NEW_PRIMARY (0x4c) · FUNC_ID_ZW_CONTROLLER_CHANGE (0x4d) · FUNC_ID_ZW_SET_LEARN_MODE (0x50) · FUNC_ID_ZW_ASSIGN_SUC_RETURN_ROUTE (0x51) · FUNC_ID_ZW_REQUEST_NETWORK_UPDATE (0x53) · FUNC_ID_ZW_SET_SUC_NODE_ID (0x54) · FUNC_ID_ZW_DELETE_SUC_RETURN_ROUTE (0x55) · GetSUCNodeId (0x56) · UNKNOWN_FUNC_SEND_SUC_ID (0x57) · FUNC_ID_ZW_EXPLORE_REQUEST_INCLUSION (0x5e) · RequestNodeInfo (0x60) · RemoveFailedNode (0x61) · IsFailedNode (0x62) · FUNC_ID_ZW_REPLACE_FAILED_NODE (0x63) · UNKNOWN_FUNC_UNKNOWN_0x66 (0x66) · UNKNOWN_FUNC_UNKNOWN_0x67 (0x67) · GetRoutingInfo (0x80) · UNKNOWN_FUNC_LOCK_ROUTE_RESPONSE (0x90) · UNKNOWN_FUNC_GET_PRIORITY_ROUTE (0x92) · UNKNOWN_FUNC_SET_PRIORITY_ROUTE (0x93) · UNKNOWN_FUNC_UNKNOWN_0x98 (0x98) · UNKNOWN_FUNC_UNKNOWN_0xB4 (0xb4) · UNKNOWN_FUNC_WATCH_DOG_ENABLE (0xb6) · UNKNOWN_FUNC_WATCH_DOG_DISABLE (0xb7) · UNKNOWN_FUNC_WATCH_DOG_KICK (0xb8) · UNKNOWN_FUNC_UNKNOWN_0xB9 (0xb9) · UNKNOWN_FUNC_RF_POWERLEVEL_GET (0xba) · UNKNOWN_FUNC_GET_LIBRARY_TYPE (0xbd) · UNKNOWN_FUNC_SEND_TEST_FRAME (0xbe) · UNKNOWN_FUNC_GET_PROTOCOL_STATUS (0xbf) · UNKNOWN_FUNC_UNKNOWN_0xD2 (0xd2) · UNKNOWN_FUNC_UNKNOWN_0xD3 (0xd3) · UNKNOWN_FUNC_UNKNOWN_0xD4 (0xd4) · undefined (0xee) · UNKNOWN_FUNC_UNKNOWN_0xEF (0xef) 20:29:23.447 CNTRLR finding SUC... 20:29:23.450 SERIAL » 0x01030056aa (5 bytes) 20:29:23.450 DRIVER » [REQ] [GetSUCNodeId] 20:29:23.451 SERIAL « [ACK] (0x06) 20:29:23.452 SERIAL « 0x0104015601ad (6 bytes) 20:29:23.452 SERIAL » [ACK] (0x06) 20:29:23.452 DRIVER « [RES] [GetSUCNodeId] payload: 0x01 20:29:23.454 CNTRLR SUC has node ID 1 20:29:23.463 CNTRLR querying node information... 20:29:23.468 SERIAL » 0x01030002fe (5 bytes) 20:29:23.468 DRIVER » [REQ] [GetSerialApiInitData] 20:29:23.469 SERIAL « [ACK] (0x06) 20:29:23.532 SERIAL « 0x0125010205081df7dfff8b0000000000000000000000000000000000000000000 (39 bytes) 0000000050090 20:29:23.533 SERIAL » [ACK] (0x06) 20:29:23.533 DRIVER « [RES] [GetSerialApiInitData] payload: 0x05081df7dfff8b000000000000000000000000000000000000000000000000000 500 20:29:23.536 CNTRLR received node information: controller role: primary controller is a SUC: true controller is a slave: false controller supports timers: false nodes in the network: 1, 2, 3, 5, 6, 7, 8, 9, 10, 11, 12, 13, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 28, 32 20:29:23.573 CNTRLR [Node 001] [Manufacturer Specific] manufacturerId: metadata updated 20:29:23.573 CNTRLR [Node 001] [Manufacturer Specific] productType: metadata updated 20:29:23.574 CNTRLR [Node 001] [Manufacturer Specific] productId: metadata updated 20:29:23.574 CNTRLR [Node 001] [+] [Manufacturer Specific] manufacturerId: 134 20:29:23.574 CNTRLR [Node 001] [+] [Manufacturer Specific] productType: 1 20:29:23.575 CNTRLR [Node 001] [+] [Manufacturer Specific] productId: 90 20:29:23.575 CNTRLR setting serial API timeouts: ack = 1000 ms, byte = 150 ms 20:29:23.577 SERIAL » 0x01050006640f97 (7 bytes) 20:29:23.577 DRIVER » [REQ] [SetSerialApiTimeouts] payload: 0x640f 20:29:23.578 SERIAL « [ACK] (0x06) 20:29:23.579 SERIAL « 0x01050106640f96 (7 bytes) 20:29:23.579 SERIAL » [ACK] (0x06) 20:29:23.579 DRIVER « [RES] [SetSerialApiTimeouts] payload: 0x640f 20:29:23.581 CNTRLR serial API timeouts overwritten. The old values were: ack = 1000 ms, byte = 15 0 ms 20:29:23.581 CNTRLR Interview completed 20:29:23.582 DRIVER driver ready 20:29:23.584 CNTRLR [Node 001] Beginning interview - last completed stage: None 20:29:23.584 CNTRLR [Node 001] new node, doing a full interview... 20:29:23.584 CNTRLR » [Node 001] querying protocol info... 20:29:23.609 SERIAL » 0x0104004101bb (6 bytes) 20:29:23.609 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x01 20:29:23.611 SERIAL « [ACK] (0x06) 20:29:23.613 SERIAL « 0x0109014193160102020133 (11 bytes) 20:29:23.613 SERIAL » [ACK] (0x06) 20:29:23.614 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0x931601020201 20:29:23.616 CNTRLR « [Node 001] received response for protocol info: basic device class: Routing Slave generic device class: Static Controller specific device class: PC Controller is a listening device: true is frequent listening: false is a routing device: false is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.619 CNTRLR [Node 001] Interview stage completed: ProtocolInfo 20:29:23.619 CNTRLR [Node 001] not pinging the controller 20:29:23.619 CNTRLR [Node 001] not querying node info from the controller 20:29:23.620 CNTRLR [Node 001] Interview stage completed: NodeInfo 20:29:23.620 CNTRLR [Node 001] Interview stage completed: CommandClasses 20:29:23.621 CNTRLR [Node 001] trying to load device config 20:29:23.624 CNTRLR [Node 001] device config loaded 20:29:23.624 CNTRLR [Node 001] Interview stage completed: OverwriteConfig 20:29:23.624 CNTRLR » [Node 001] requesting node neighbors... 20:29:23.627 SERIAL » 0x010700800100000079 (9 bytes) 20:29:23.627 DRIVER » [Node 001] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 20:29:23.628 SERIAL « [ACK] (0x06) 20:29:23.630 SERIAL « 0x01200180f6dfff8b0000000000000000000000000000000000000000000000000 (34 bytes) 003 20:29:23.630 SERIAL » [ACK] (0x06) 20:29:23.631 DRIVER « [RES] [GetRoutingInfo] node ids: 2, 3, 5, 6, 7, 8, 9, 10, 11, 12, 13, 15, 16, 17, 18, 19, 20, 21, 2 2, 23, 24, 25, 26, 28, 32 20:29:23.632 CNTRLR [Node 001] The node is alive. 20:29:23.633 CNTRLR « [Node 001] node neighbors received: 2, 3, 5, 6, 7, 8, 9, 10, 11, 12, 13, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 28, 32 20:29:23.633 CNTRLR [Node 001] Interview stage completed: Neighbors 20:29:23.633 CNTRLR [Node 001] Interview completed 20:29:23.633 CNTRLR [Node 001] The node is ready to be used 20:29:23.634 CNTRLR [Node 002] Beginning interview - last completed stage: None 20:29:23.634 CNTRLR [Node 002] new node, doing a full interview... 20:29:23.634 CNTRLR » [Node 002] querying protocol info... 20:29:23.636 SERIAL » 0x0104004102b8 (6 bytes) 20:29:23.636 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x02 20:29:23.636 CNTRLR [Node 003] Beginning interview - last completed stage: None 20:29:23.636 CNTRLR [Node 003] new node, doing a full interview... 20:29:23.636 CNTRLR » [Node 003] querying protocol info... 20:29:23.637 CNTRLR [Node 005] Beginning interview - last completed stage: None 20:29:23.637 CNTRLR [Node 005] new node, doing a full interview... 20:29:23.637 CNTRLR » [Node 005] querying protocol info... 20:29:23.638 CNTRLR [Node 006] Beginning interview - last completed stage: None 20:29:23.638 CNTRLR [Node 006] new node, doing a full interview... 20:29:23.638 CNTRLR » [Node 006] querying protocol info... 20:29:23.639 CNTRLR [Node 007] Beginning interview - last completed stage: None 20:29:23.639 CNTRLR [Node 007] new node, doing a full interview... 20:29:23.639 CNTRLR » [Node 007] querying protocol info... 20:29:23.640 CNTRLR [Node 008] Beginning interview - last completed stage: None 20:29:23.640 CNTRLR [Node 008] new node, doing a full interview... 20:29:23.640 CNTRLR » [Node 008] querying protocol info... 20:29:23.641 CNTRLR [Node 009] Beginning interview - last completed stage: None 20:29:23.641 CNTRLR [Node 009] new node, doing a full interview... 20:29:23.641 CNTRLR » [Node 009] querying protocol info... 20:29:23.642 CNTRLR [Node 010] Beginning interview - last completed stage: None 20:29:23.642 CNTRLR [Node 010] new node, doing a full interview... 20:29:23.642 CNTRLR » [Node 010] querying protocol info... 20:29:23.643 CNTRLR [Node 011] Beginning interview - last completed stage: None 20:29:23.643 CNTRLR [Node 011] new node, doing a full interview... 20:29:23.643 CNTRLR » [Node 011] querying protocol info... 20:29:23.644 CNTRLR [Node 012] Beginning interview - last completed stage: None 20:29:23.644 CNTRLR [Node 012] new node, doing a full interview... 20:29:23.644 CNTRLR » [Node 012] querying protocol info... 20:29:23.645 CNTRLR [Node 013] Beginning interview - last completed stage: None 20:29:23.645 CNTRLR [Node 013] new node, doing a full interview... 20:29:23.645 CNTRLR » [Node 013] querying protocol info... 20:29:23.645 CNTRLR [Node 015] Beginning interview - last completed stage: None 20:29:23.645 CNTRLR [Node 015] new node, doing a full interview... 20:29:23.646 CNTRLR » [Node 015] querying protocol info... 20:29:23.646 CNTRLR [Node 016] Beginning interview - last completed stage: None 20:29:23.646 CNTRLR [Node 016] new node, doing a full interview... 20:29:23.646 CNTRLR » [Node 016] querying protocol info... 20:29:23.647 CNTRLR [Node 017] Beginning interview - last completed stage: None 20:29:23.647 CNTRLR [Node 017] new node, doing a full interview... 20:29:23.647 CNTRLR » [Node 017] querying protocol info... 20:29:23.648 CNTRLR [Node 018] Beginning interview - last completed stage: None 20:29:23.648 CNTRLR [Node 018] new node, doing a full interview... 20:29:23.648 CNTRLR » [Node 018] querying protocol info... 20:29:23.649 CNTRLR [Node 019] Beginning interview - last completed stage: None 20:29:23.649 CNTRLR [Node 019] new node, doing a full interview... 20:29:23.649 CNTRLR » [Node 019] querying protocol info... 20:29:23.650 CNTRLR [Node 020] Beginning interview - last completed stage: None 20:29:23.650 CNTRLR [Node 020] new node, doing a full interview... 20:29:23.650 CNTRLR » [Node 020] querying protocol info... 20:29:23.651 CNTRLR [Node 021] Beginning interview - last completed stage: None 20:29:23.651 CNTRLR [Node 021] new node, doing a full interview... 20:29:23.651 CNTRLR » [Node 021] querying protocol info... 20:29:23.651 CNTRLR [Node 022] Beginning interview - last completed stage: None 20:29:23.652 CNTRLR [Node 022] new node, doing a full interview... 20:29:23.652 CNTRLR » [Node 022] querying protocol info... 20:29:23.652 CNTRLR [Node 023] Beginning interview - last completed stage: None 20:29:23.652 CNTRLR [Node 023] new node, doing a full interview... 20:29:23.653 CNTRLR » [Node 023] querying protocol info... 20:29:23.653 CNTRLR [Node 024] Beginning interview - last completed stage: None 20:29:23.653 CNTRLR [Node 024] new node, doing a full interview... 20:29:23.653 CNTRLR » [Node 024] querying protocol info... 20:29:23.654 CNTRLR [Node 025] Beginning interview - last completed stage: None 20:29:23.654 CNTRLR [Node 025] new node, doing a full interview... 20:29:23.654 CNTRLR » [Node 025] querying protocol info... 20:29:23.655 CNTRLR [Node 026] Beginning interview - last completed stage: None 20:29:23.655 CNTRLR [Node 026] new node, doing a full interview... 20:29:23.655 CNTRLR » [Node 026] querying protocol info... 20:29:23.656 CNTRLR [Node 028] Beginning interview - last completed stage: None 20:29:23.656 CNTRLR [Node 028] new node, doing a full interview... 20:29:23.656 CNTRLR » [Node 028] querying protocol info... 20:29:23.657 CNTRLR [Node 032] Beginning interview - last completed stage: None 20:29:23.657 CNTRLR [Node 032] new node, doing a full interview... 20:29:23.657 CNTRLR » [Node 032] querying protocol info... 20:29:23.659 SERIAL « [ACK] (0x06) 20:29:23.660 SERIAL « 0x01090141d39c01041001ed (11 bytes) 20:29:23.660 SERIAL » [ACK] (0x06) 20:29:23.661 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0xd39c01041001 20:29:23.663 SERIAL » 0x0104004103b9 (6 bytes) 20:29:23.663 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x03 20:29:23.663 CNTRLR « [Node 002] received response for protocol info: basic device class: Static Controller generic device class: Binary Switch specific device class: Binary Power Switch is a listening device: true is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.664 CNTRLR [Node 002] Interview stage completed: ProtocolInfo 20:29:23.664 CNTRLR » [Node 002] pinging the node... 20:29:23.667 SERIAL « [ACK] (0x06) 20:29:23.668 SERIAL « 0x01090141d39c01041001ed (11 bytes) 20:29:23.668 SERIAL » [ACK] (0x06) 20:29:23.668 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0xd39c01041001 20:29:23.676 SERIAL » 0x0104004105bf (6 bytes) 20:29:23.676 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x05 20:29:23.676 CNTRLR « [Node 003] received response for protocol info: basic device class: Static Controller generic device class: Binary Switch specific device class: Binary Power Switch is a listening device: true is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.676 CNTRLR [Node 003] Interview stage completed: ProtocolInfo 20:29:23.676 CNTRLR » [Node 003] pinging the node... 20:29:23.678 SERIAL « [ACK] (0x06) 20:29:23.679 SERIAL « 0x01090141d39c01041001ed (11 bytes) 20:29:23.679 SERIAL » [ACK] (0x06) 20:29:23.681 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0xd39c01041001 20:29:23.683 SERIAL » 0x0104004106bc (6 bytes) 20:29:23.684 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x06 20:29:23.684 CNTRLR « [Node 005] received response for protocol info: basic device class: Static Controller generic device class: Binary Switch specific device class: Binary Power Switch is a listening device: true is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.684 CNTRLR [Node 005] Interview stage completed: ProtocolInfo 20:29:23.684 CNTRLR » [Node 005] pinging the node... 20:29:23.686 SERIAL « [ACK] (0x06) 20:29:23.687 SERIAL « 0x01090141d39c01041001ed (11 bytes) 20:29:23.687 SERIAL » [ACK] (0x06) 20:29:23.687 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0xd39c01041001 20:29:23.693 SERIAL » 0x0104004107bd (6 bytes) 20:29:23.693 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x07 20:29:23.694 CNTRLR « [Node 006] received response for protocol info: basic device class: Static Controller generic device class: Binary Switch specific device class: Binary Power Switch is a listening device: true is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.694 CNTRLR [Node 006] Interview stage completed: ProtocolInfo 20:29:23.694 CNTRLR » [Node 006] pinging the node... 20:29:23.697 SERIAL « [ACK] (0x06) 20:29:23.698 SERIAL « 0x01090141539c010407017a (11 bytes) 20:29:23.698 SERIAL » [ACK] (0x06) 20:29:23.698 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0x539c01040701 20:29:23.702 SERIAL » 0x0104004108b2 (6 bytes) 20:29:23.702 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x08 20:29:23.702 CNTRLR « [Node 007] received response for protocol info: basic device class: Static Controller generic device class: Notification Sensor specific device class: Notification Sensor is a listening device: false is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.703 CNTRLR [Node 007] The node is awake. 20:29:23.703 CNTRLR [Node 007] Interview stage completed: ProtocolInfo 20:29:23.704 CNTRLR » [Node 007] pinging the node... 20:29:23.706 SERIAL « [ACK] (0x06) 20:29:23.707 SERIAL « 0x01090141539c010407017a (11 bytes) 20:29:23.707 SERIAL » [ACK] (0x06) 20:29:23.708 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0x539c01040701 20:29:23.710 SERIAL » 0x0104004109b3 (6 bytes) 20:29:23.710 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x09 20:29:23.710 CNTRLR « [Node 008] received response for protocol info: basic device class: Static Controller generic device class: Notification Sensor specific device class: Notification Sensor is a listening device: false is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.711 CNTRLR [Node 008] The node is awake. 20:29:23.711 CNTRLR [Node 008] Interview stage completed: ProtocolInfo 20:29:23.711 CNTRLR » [Node 008] pinging the node... 20:29:23.713 SERIAL « [ACK] (0x06) 20:29:23.714 SERIAL « 0x01090141539c010407017a (11 bytes) 20:29:23.714 SERIAL » [ACK] (0x06) 20:29:23.714 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0x539c01040701 20:29:23.718 SERIAL » 0x010400410ab0 (6 bytes) 20:29:23.718 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x0a 20:29:23.718 CNTRLR « [Node 009] received response for protocol info: basic device class: Static Controller generic device class: Notification Sensor specific device class: Notification Sensor is a listening device: false is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.719 CNTRLR [Node 009] The node is awake. 20:29:23.719 CNTRLR [Node 009] Interview stage completed: ProtocolInfo 20:29:23.719 CNTRLR » [Node 009] pinging the node... 20:29:23.722 SERIAL « [ACK] (0x06) 20:29:23.722 SERIAL « 0x01090141539c010407017a (11 bytes) 20:29:23.722 SERIAL » [ACK] (0x06) 20:29:23.723 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0x539c01040701 20:29:23.725 SERIAL » 0x010400410bb1 (6 bytes) 20:29:23.725 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x0b 20:29:23.725 CNTRLR « [Node 010] received response for protocol info: basic device class: Static Controller generic device class: Notification Sensor specific device class: Notification Sensor is a listening device: false is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.726 CNTRLR [Node 010] The node is awake. 20:29:23.726 CNTRLR [Node 010] Interview stage completed: ProtocolInfo 20:29:23.726 CNTRLR » [Node 010] pinging the node... 20:29:23.728 SERIAL « [ACK] (0x06) 20:29:23.729 SERIAL « 0x01090141539c010407017a (11 bytes) 20:29:23.729 SERIAL » [ACK] (0x06) 20:29:23.729 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0x539c01040701 20:29:23.732 SERIAL » 0x010400410cb6 (6 bytes) 20:29:23.733 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x0c 20:29:23.733 CNTRLR « [Node 011] received response for protocol info: basic device class: Static Controller generic device class: Notification Sensor specific device class: Notification Sensor is a listening device: false is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.733 CNTRLR [Node 011] The node is awake. 20:29:23.733 CNTRLR [Node 011] Interview stage completed: ProtocolInfo 20:29:23.734 CNTRLR » [Node 011] pinging the node... 20:29:23.735 SERIAL « [ACK] (0x06) 20:29:23.736 SERIAL « 0x01090141539c010407017a (11 bytes) 20:29:23.736 SERIAL » [ACK] (0x06) 20:29:23.736 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0x539c01040701 20:29:23.738 SERIAL » 0x010400410db7 (6 bytes) 20:29:23.739 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x0d 20:29:23.739 CNTRLR « [Node 012] received response for protocol info: basic device class: Static Controller generic device class: Notification Sensor specific device class: Notification Sensor is a listening device: false is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.739 CNTRLR [Node 012] The node is awake. 20:29:23.740 CNTRLR [Node 012] Interview stage completed: ProtocolInfo 20:29:23.740 CNTRLR » [Node 012] pinging the node... 20:29:23.741 SERIAL « [ACK] (0x06) 20:29:23.742 SERIAL « 0x01090141539c010407017a (11 bytes) 20:29:23.742 SERIAL » [ACK] (0x06) 20:29:23.742 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0x539c01040701 20:29:23.744 SERIAL » 0x010400410fb5 (6 bytes) 20:29:23.744 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x0f 20:29:23.745 CNTRLR « [Node 013] received response for protocol info: basic device class: Static Controller generic device class: Notification Sensor specific device class: Notification Sensor is a listening device: false is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.745 CNTRLR [Node 013] The node is awake. 20:29:23.745 CNTRLR [Node 013] Interview stage completed: ProtocolInfo 20:29:23.745 CNTRLR » [Node 013] pinging the node... 20:29:23.746 SERIAL « [ACK] (0x06) 20:29:23.747 SERIAL « 0x01090141539c010407017a (11 bytes) 20:29:23.747 SERIAL » [ACK] (0x06) 20:29:23.747 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0x539c01040701 20:29:23.749 SERIAL » 0x0104004110aa (6 bytes) 20:29:23.750 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x10 20:29:23.750 CNTRLR « [Node 015] received response for protocol info: basic device class: Static Controller generic device class: Notification Sensor specific device class: Notification Sensor is a listening device: false is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.750 CNTRLR [Node 015] The node is awake. 20:29:23.750 CNTRLR [Node 015] Interview stage completed: ProtocolInfo 20:29:23.750 CNTRLR » [Node 015] pinging the node... 20:29:23.752 SERIAL « [ACK] (0x06) 20:29:23.755 SERIAL « 0x01090141539c010421015c (11 bytes) 20:29:23.756 SERIAL » [ACK] (0x06) 20:29:23.756 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0x539c01042101 20:29:23.758 SERIAL » 0x0104004111ab (6 bytes) 20:29:23.758 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x11 20:29:23.759 CNTRLR « [Node 016] received response for protocol info: basic device class: Static Controller generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is a listening device: false is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.759 CNTRLR [Node 016] The node is awake. 20:29:23.759 CNTRLR [Node 016] Interview stage completed: ProtocolInfo 20:29:23.759 CNTRLR » [Node 016] pinging the node... 20:29:23.761 SERIAL « [ACK] (0x06) 20:29:23.761 SERIAL « 0x01090141539c0004080471 (11 bytes) 20:29:23.761 SERIAL » [ACK] (0x06) 20:29:23.762 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0x539c00040804 20:29:23.764 SERIAL » 0x0104004112a8 (6 bytes) 20:29:23.764 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x12 20:29:23.764 CNTRLR « [Node 017] received response for protocol info: basic device class: Static Controller generic device class: Thermostat specific device class: Setpoint Thermostat is a listening device: false is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.764 CNTRLR [Node 017] The node is awake. 20:29:23.765 CNTRLR [Node 017] Interview stage completed: ProtocolInfo 20:29:23.765 CNTRLR » [Node 017] pinging the node... 20:29:23.766 SERIAL « [ACK] (0x06) 20:29:23.767 SERIAL « 0x01090141d39c01041001ed (11 bytes) 20:29:23.767 SERIAL » [ACK] (0x06) 20:29:23.767 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0xd39c01041001 20:29:23.780 SERIAL » 0x0104004113a9 (6 bytes) 20:29:23.780 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x13 20:29:23.780 CNTRLR « [Node 018] received response for protocol info: basic device class: Static Controller generic device class: Binary Switch specific device class: Binary Power Switch is a listening device: true is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.783 SERIAL « [ACK] (0x06) 20:29:23.784 SERIAL « 0x01090141d39c01041001ed (11 bytes) 20:29:23.784 SERIAL » [ACK] (0x06) 20:29:23.785 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0xd39c01041001 20:29:23.787 SERIAL » 0x0104004114ae (6 bytes) 20:29:23.787 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x14 20:29:23.787 CNTRLR « [Node 019] received response for protocol info: basic device class: Static Controller generic device class: Binary Switch specific device class: Binary Power Switch is a listening device: true is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.787 CNTRLR [Node 019] Interview stage completed: ProtocolInfo 20:29:23.787 CNTRLR » [Node 019] pinging the node... 20:29:23.789 CNTRLR [Node 018] Interview stage completed: ProtocolInfo 20:29:23.789 CNTRLR » [Node 018] pinging the node... 20:29:23.790 SERIAL « [ACK] (0x06) 20:29:23.791 SERIAL « 0x01090141d39c01041001ed (11 bytes) 20:29:23.791 SERIAL » [ACK] (0x06) 20:29:23.792 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0xd39c01041001 20:29:23.794 SERIAL » 0x0104004115af (6 bytes) 20:29:23.795 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x15 20:29:23.795 CNTRLR « [Node 020] received response for protocol info: basic device class: Static Controller generic device class: Binary Switch specific device class: Binary Power Switch is a listening device: true is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.795 CNTRLR [Node 020] Interview stage completed: ProtocolInfo 20:29:23.795 CNTRLR » [Node 020] pinging the node... 20:29:23.797 SERIAL « [ACK] (0x06) 20:29:23.798 SERIAL « 0x0109014153dc0104080632 (11 bytes) 20:29:23.798 SERIAL » [ACK] (0x06) 20:29:23.798 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0x53dc01040806 20:29:23.801 SERIAL » 0x0104004116ac (6 bytes) 20:29:23.801 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x16 20:29:23.801 CNTRLR « [Node 021] received response for protocol info: basic device class: Static Controller generic device class: Thermostat specific device class: Thermostat General V2 is a listening device: false is frequent listening: true is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.801 CNTRLR [Node 021] Interview stage completed: ProtocolInfo 20:29:23.801 CNTRLR » [Node 021] pinging the node... 20:29:23.804 SERIAL « [ACK] (0x06) 20:29:23.804 SERIAL « 0x0109014153dc0104080632 (11 bytes) 20:29:23.804 SERIAL » [ACK] (0x06) 20:29:23.805 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0x53dc01040806 20:29:23.807 SERIAL » 0x0104004117ad (6 bytes) 20:29:23.807 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x17 20:29:23.807 CNTRLR « [Node 022] received response for protocol info: basic device class: Static Controller generic device class: Thermostat specific device class: Thermostat General V2 is a listening device: false is frequent listening: true is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.807 CNTRLR [Node 022] Interview stage completed: ProtocolInfo 20:29:23.808 CNTRLR » [Node 022] pinging the node... 20:29:23.810 SERIAL « [ACK] (0x06) 20:29:23.810 SERIAL « 0x0109014153dc0104080632 (11 bytes) 20:29:23.810 SERIAL » [ACK] (0x06) 20:29:23.811 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0x53dc01040806 20:29:23.814 SERIAL » 0x0104004118a2 (6 bytes) 20:29:23.814 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x18 20:29:23.814 CNTRLR « [Node 023] received response for protocol info: basic device class: Static Controller generic device class: Thermostat specific device class: Thermostat General V2 is a listening device: false is frequent listening: true is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.814 CNTRLR [Node 023] Interview stage completed: ProtocolInfo 20:29:23.814 CNTRLR » [Node 023] pinging the node... 20:29:23.816 SERIAL « [ACK] (0x06) 20:29:23.817 SERIAL « 0x0109014153dc0104080632 (11 bytes) 20:29:23.817 SERIAL » [ACK] (0x06) 20:29:23.817 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0x53dc01040806 20:29:23.820 SERIAL » 0x0104004119a3 (6 bytes) 20:29:23.820 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x19 20:29:23.820 CNTRLR « [Node 024] received response for protocol info: basic device class: Static Controller generic device class: Thermostat specific device class: Thermostat General V2 is a listening device: false is frequent listening: true is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.820 CNTRLR [Node 024] Interview stage completed: ProtocolInfo 20:29:23.820 CNTRLR » [Node 024] pinging the node... 20:29:23.822 SERIAL « [ACK] (0x06) 20:29:23.823 SERIAL « 0x01090141539c010407017a (11 bytes) 20:29:23.823 SERIAL » [ACK] (0x06) 20:29:23.824 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0x539c01040701 20:29:23.826 SERIAL » 0x010400411aa0 (6 bytes) 20:29:23.826 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x1a 20:29:23.826 CNTRLR « [Node 025] received response for protocol info: basic device class: Static Controller generic device class: Notification Sensor specific device class: Notification Sensor is a listening device: false is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.827 CNTRLR [Node 025] The node is awake. 20:29:23.827 CNTRLR [Node 025] Interview stage completed: ProtocolInfo 20:29:23.827 CNTRLR » [Node 025] pinging the node... 20:29:23.828 SERIAL « [ACK] (0x06) 20:29:23.829 SERIAL « 0x01090141d39c01041001ed (11 bytes) 20:29:23.829 SERIAL » [ACK] (0x06) 20:29:23.829 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0xd39c01041001 20:29:23.833 SERIAL » 0x010400411ca6 (6 bytes) 20:29:23.834 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x1c 20:29:23.834 CNTRLR « [Node 026] received response for protocol info: basic device class: Static Controller generic device class: Binary Switch specific device class: Binary Power Switch is a listening device: true is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.834 CNTRLR [Node 026] Interview stage completed: ProtocolInfo 20:29:23.834 CNTRLR » [Node 026] pinging the node... 20:29:23.837 SERIAL « [ACK] (0x06) 20:29:23.838 SERIAL « 0x01090141d39c01041001ed (11 bytes) 20:29:23.838 SERIAL » [ACK] (0x06) 20:29:23.839 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0xd39c01041001 20:29:23.842 SERIAL » 0x01040041209a (6 bytes) 20:29:23.842 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x20 20:29:23.843 CNTRLR « [Node 028] received response for protocol info: basic device class: Static Controller generic device class: Binary Switch specific device class: Binary Power Switch is a listening device: true is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.843 CNTRLR [Node 028] Interview stage completed: ProtocolInfo 20:29:23.843 CNTRLR » [Node 028] pinging the node... 20:29:23.845 SERIAL « [ACK] (0x06) 20:29:23.846 SERIAL « 0x01090141539c000421015d (11 bytes) 20:29:23.846 SERIAL » [ACK] (0x06) 20:29:23.846 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0x539c00042101 20:29:23.849 SERIAL » 0x010800130201002501c3 (10 bytes) 20:29:23.849 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 1 └─[NoOperationCC] 20:29:23.850 CNTRLR « [Node 032] received response for protocol info: basic device class: Static Controller generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is a listening device: false is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 20:29:23.850 CNTRLR [Node 032] The node is awake. 20:29:23.850 CNTRLR [Node 032] Interview stage completed: ProtocolInfo 20:29:23.850 CNTRLR » [Node 032] pinging the node... 20:29:23.854 SERIAL « [ACK] (0x06) 20:29:23.855 SERIAL « 0x0104011301e8 (6 bytes) 20:29:23.855 SERIAL » [ACK] (0x06) 20:29:23.856 DRIVER « [RES] [SendData] was sent: true 20:29:23.874 SERIAL « 0x0107001301000002e8 (9 bytes) 20:29:23.874 SERIAL » [ACK] (0x06) 20:29:23.874 DRIVER « [REQ] [SendData] callback id: 1 transmit status: OK 20:29:23.880 SERIAL » 0x010800130301002502c1 (10 bytes) 20:29:23.880 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 2 └─[NoOperationCC] 20:29:23.881 CNTRLR « [Node 002] ping successful 20:29:23.881 CNTRLR » [Node 002] querying node info... 20:29:23.884 SERIAL « [ACK] (0x06) 20:29:23.886 SERIAL « 0x0104011301e8 (6 bytes) 20:29:23.886 SERIAL » [ACK] (0x06) 20:29:23.887 DRIVER « [RES] [SendData] was sent: true 20:29:23.905 SERIAL « 0x0107001302000002eb (9 bytes) 20:29:23.905 SERIAL » [ACK] (0x06) 20:29:23.905 DRIVER « [REQ] [SendData] callback id: 2 transmit status: OK 20:29:23.913 SERIAL » 0x010800130501002503c6 (10 bytes) 20:29:23.913 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 3 └─[NoOperationCC] 20:29:23.913 CNTRLR « [Node 003] ping successful 20:29:23.913 CNTRLR » [Node 003] querying node info... 20:29:23.915 SERIAL « [ACK] (0x06) 20:29:23.918 SERIAL « 0x0104011301e8 (6 bytes) 20:29:23.918 SERIAL » [ACK] (0x06) 20:29:23.919 DRIVER « [RES] [SendData] was sent: true 20:29:24.366 SERIAL « 0x010700130300002dc5 (9 bytes) 20:29:24.366 SERIAL » [ACK] (0x06) 20:29:24.367 DRIVER « [REQ] [SendData] callback id: 3 transmit status: OK 20:29:24.372 SERIAL » 0x010800130601002504c2 (10 bytes) 20:29:24.372 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 4 └─[NoOperationCC] 20:29:24.372 CNTRLR « [Node 005] ping successful 20:29:24.372 CNTRLR » [Node 005] querying node info... 20:29:24.376 SERIAL « [ACK] (0x06) 20:29:24.377 SERIAL « 0x0104011301e8 (6 bytes) 20:29:24.377 SERIAL » [ACK] (0x06) 20:29:24.377 DRIVER « [RES] [SendData] was sent: true 20:29:24.406 SERIAL « 0x0107001304000003ec (9 bytes) 20:29:24.407 SERIAL » [ACK] (0x06) 20:29:24.408 DRIVER « [REQ] [SendData] callback id: 4 transmit status: OK 20:29:24.414 SERIAL » 0x010400600299 (6 bytes) 20:29:24.414 DRIVER » [Node 002] [REQ] [RequestNodeInfo] payload: 0x02 20:29:24.415 CNTRLR « [Node 006] ping successful 20:29:24.415 CNTRLR » [Node 006] querying node info... 20:29:24.418 SERIAL « [ACK] (0x06) 20:29:24.419 SERIAL « 0x01040160019b (6 bytes) 20:29:24.420 SERIAL » [ACK] (0x06) 20:29:24.421 DRIVER « [RES] [RequestNodeInfo] payload: 0x01 20:29:24.511 SERIAL « 0x011900498402130410015e8672985a855973252027327071757af6 (27 bytes) 20:29:24.512 SERIAL » [ACK] (0x06) 20:29:24.513 DRIVER « [Node 002] [REQ] [ApplicationUpdateRequest] payload: 0x8402130410015e8672985a855973252027327071757a 20:29:24.522 SERIAL » 0x010400600398 (6 bytes) 20:29:24.522 DRIVER » [Node 003] [REQ] [RequestNodeInfo] payload: 0x03 20:29:24.523 CNTRLR [Node 002] The node is alive. 20:29:24.524 CNTRLR « [Node 002] node info received supported CCs: · Z-Wave Plus Info · Version · Manufacturer Specific · Security · Device Reset Locally · Association · Association Group Information · Powerlevel · Binary Switch · Basic · All Switch · Meter · Configuration · Notification · Protection · Firmware Update Meta Data controlled CCs: 20:29:24.530 SERIAL « [ACK] (0x06) 20:29:24.532 SERIAL « 0x01040160019b (6 bytes) 20:29:24.533 SERIAL » [ACK] (0x06) 20:29:24.534 DRIVER « [RES] [RequestNodeInfo] payload: 0x01 20:29:24.539 CNTRLR [Node 002] Interview stage completed: NodeInfo 20:29:24.542 CNTRLR » [Node 002] querying securely supported commands... 20:29:24.567 SERIAL « 0x011a00498403140410015e22855970565a7a72328e7173983125864a (28 bytes) 20:29:24.567 SERIAL » [ACK] (0x06) 20:29:24.568 DRIVER « [Node 003] [REQ] [ApplicationUpdateRequest] payload: 0x8403140410015e22855970565a7a72328e717398312586 20:29:24.572 SERIAL » 0x01040060059e (6 bytes) 20:29:24.572 DRIVER » [Node 005] [REQ] [RequestNodeInfo] payload: 0x05 20:29:24.573 CNTRLR [Node 003] The node is alive. 20:29:24.573 CNTRLR « [Node 003] node info received supported CCs: · Z-Wave Plus Info · Application Status · Association · Association Group Information · Configuration · CRC-16 Encapsulation · Device Reset Locally · Firmware Update Meta Data · Manufacturer Specific · Meter · Multi Channel Association · Notification · Powerlevel · Security · Multilevel Sensor · Binary Switch · Version controlled CCs: 20:29:24.574 CNTRLR [Node 003] Interview stage completed: NodeInfo 20:29:24.574 CNTRLR » [Node 003] querying securely supported commands... 20:29:24.577 SERIAL « [ACK] (0x06) 20:29:24.578 SERIAL « 0x01040160019b (6 bytes) 20:29:24.578 SERIAL » [ACK] (0x06) 20:29:24.579 DRIVER « [RES] [RequestNodeInfo] payload: 0x01 20:29:24.873 SERIAL « 0x011900498405130410015e86725a7385592571703227752c2b7a4e (27 bytes) 20:29:24.873 SERIAL » [ACK] (0x06) 20:29:24.874 DRIVER « [Node 005] [REQ] [ApplicationUpdateRequest] payload: 0x8405130410015e86725a7385592571703227752c2b7a 20:29:24.878 SERIAL » 0x01040060069d (6 bytes) 20:29:24.878 DRIVER » [Node 006] [REQ] [RequestNodeInfo] payload: 0x06 20:29:24.878 CNTRLR [Node 005] The node is alive. 20:29:24.879 CNTRLR « [Node 005] node info received supported CCs: · Z-Wave Plus Info · Version · Manufacturer Specific · Device Reset Locally · Powerlevel · Association · Association Group Information · Binary Switch · Notification · Configuration · Meter · All Switch · Protection · Scene Actuator Configuration · Scene Activation · Firmware Update Meta Data controlled CCs: 20:29:24.882 SERIAL « [ACK] (0x06) 20:29:24.883 CNTRLR [Node 005] Interview stage completed: NodeInfo 20:29:24.886 CNTRLR [Node 005] ManufacturerSpecificCC: doing a complete interview... 20:29:24.886 CNTRLR » [Node 005] querying manufacturer information... 20:29:24.889 SERIAL « 0x01040160019b (6 bytes) 20:29:24.889 SERIAL » [ACK] (0x06) 20:29:24.890 DRIVER « [RES] [RequestNodeInfo] payload: 0x01 20:29:25.018 SERIAL « 0x011900498406130410015e86725a7385592571703227752c2b7a4d (27 bytes) 20:29:25.019 SERIAL » [ACK] (0x06) 20:29:25.019 DRIVER « [Node 006] [REQ] [ApplicationUpdateRequest] payload: 0x8406130410015e86725a7385592571703227752c2b7a 20:29:25.038 SERIAL » 0x010900130202984025051d (11 bytes) 20:29:25.039 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 5 └─[SecurityCCNonceGet] 20:29:25.039 CNTRLR [Node 006] The node is alive. 20:29:25.041 CNTRLR « [Node 006] node info received supported CCs: · Z-Wave Plus Info · Version · Manufacturer Specific · Device Reset Locally · Powerlevel · Association · Association Group Information · Binary Switch · Notification · Configuration · Meter · All Switch · Protection · Scene Actuator Configuration · Scene Activation · Firmware Update Meta Data controlled CCs: 20:29:25.046 SERIAL « [ACK] (0x06) 20:29:25.049 SERIAL « 0x0104011301e8 (6 bytes) 20:29:25.049 SERIAL » [ACK] (0x06) 20:29:25.050 DRIVER « [RES] [SendData] was sent: true 20:29:25.054 CNTRLR [Node 006] Interview stage completed: NodeInfo 20:29:25.057 CNTRLR [Node 006] ManufacturerSpecificCC: doing a complete interview... 20:29:25.057 CNTRLR » [Node 006] querying manufacturer information... 20:29:25.064 SERIAL « 0x0107001305000002ec (9 bytes) 20:29:25.065 SERIAL » [ACK] (0x06) 20:29:25.065 DRIVER « [REQ] [SendData] callback id: 5 transmit status: OK 20:29:26.669 CNTRLR [Node 002] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 20:29:27.174 SERIAL » 0x010900130202984025061e (11 bytes) 20:29:27.174 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 6 └─[SecurityCCNonceGet] 20:29:27.176 SERIAL « [ACK] (0x06) 20:29:27.180 SERIAL « 0x0104011301e8 (6 bytes) 20:29:27.180 SERIAL » [ACK] (0x06) 20:29:27.180 DRIVER « [RES] [SendData] was sent: true 20:29:27.199 SERIAL « 0x0107001306000002ef (9 bytes) 20:29:27.200 SERIAL » [ACK] (0x06) 20:29:27.200 DRIVER « [REQ] [SendData] callback id: 6 transmit status: OK 20:29:28.803 CNTRLR [Node 002] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 20:29:29.309 SERIAL » 0x010900130202984025071f (11 bytes) 20:29:29.309 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 7 └─[SecurityCCNonceGet] 20:29:29.311 SERIAL « [ACK] (0x06) 20:29:29.315 SERIAL « 0x0104011301e8 (6 bytes) 20:29:29.315 SERIAL » [ACK] (0x06) 20:29:29.316 DRIVER « [RES] [SendData] was sent: true 20:29:29.334 SERIAL « 0x0107001307000002ee (9 bytes) 20:29:29.335 SERIAL » [ACK] (0x06) 20:29:29.335 DRIVER « [REQ] [SendData] callback id: 7 transmit status: OK 20:29:30.947 SERIAL » 0x0109001303029840250811 (11 bytes) 20:29:30.947 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 8 └─[SecurityCCNonceGet] 20:29:30.947 CNTRLR [Node 002] The node is not included securely. Continuing interview non-securel y. 20:29:30.948 CNTRLR [Node 002] ManufacturerSpecificCC: doing a complete interview... 20:29:30.949 CNTRLR » [Node 002] querying manufacturer information... 20:29:30.950 SERIAL « [ACK] (0x06) 20:29:30.952 SERIAL « 0x0104011301e8 (6 bytes) 20:29:30.952 SERIAL » [ACK] (0x06) 20:29:30.953 DRIVER « [RES] [SendData] was sent: true 20:29:30.972 SERIAL « 0x0107001308000003e0 (9 bytes) 20:29:30.972 SERIAL » [ACK] (0x06) 20:29:30.972 DRIVER « [REQ] [SendData] callback id: 8 transmit status: OK 20:29:32.576 CNTRLR [Node 003] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 20:29:33.082 SERIAL » 0x0109001303029840250910 (11 bytes) 20:29:33.082 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 9 └─[SecurityCCNonceGet] 20:29:33.084 SERIAL « [ACK] (0x06) 20:29:33.088 SERIAL « 0x0104011301e8 (6 bytes) 20:29:33.088 SERIAL » [ACK] (0x06) 20:29:33.089 DRIVER « [RES] [SendData] was sent: true 20:29:33.107 SERIAL « 0x0107001309000002e0 (9 bytes) 20:29:33.107 SERIAL » [ACK] (0x06) 20:29:33.108 DRIVER « [REQ] [SendData] callback id: 9 transmit status: OK 20:29:33.704 DRIVER The awake timeout for node 7 has elapsed. Assuming it is asleep. 20:29:33.705 CNTRLR [Node 007] The node is now asleep. 20:29:33.708 CNTRLR [Node 007] ping failed: The node is asleep 20:29:33.708 CNTRLR » [Node 007] querying node info... 20:29:33.711 DRIVER The awake timeout for node 8 has elapsed. Assuming it is asleep. 20:29:33.711 CNTRLR [Node 008] The node is now asleep. 20:29:33.712 CNTRLR [Node 008] ping failed: The node is asleep 20:29:33.712 CNTRLR » [Node 008] querying node info... 20:29:33.720 DRIVER The awake timeout for node 9 has elapsed. Assuming it is asleep. 20:29:33.720 CNTRLR [Node 009] The node is now asleep. 20:29:33.721 CNTRLR [Node 009] ping failed: The node is asleep 20:29:33.721 CNTRLR » [Node 009] querying node info... 20:29:33.727 DRIVER The awake timeout for node 10 has elapsed. Assuming it is asleep. 20:29:33.727 CNTRLR [Node 010] The node is now asleep. 20:29:33.728 CNTRLR [Node 010] ping failed: The node is asleep 20:29:33.728 CNTRLR » [Node 010] querying node info... 20:29:33.733 DRIVER The awake timeout for node 11 has elapsed. Assuming it is asleep. 20:29:33.733 CNTRLR [Node 011] The node is now asleep. 20:29:33.734 CNTRLR [Node 011] ping failed: The node is asleep 20:29:33.734 CNTRLR » [Node 011] querying node info... 20:29:33.739 DRIVER The awake timeout for node 12 has elapsed. Assuming it is asleep. 20:29:33.740 CNTRLR [Node 012] The node is now asleep. 20:29:33.740 CNTRLR [Node 012] ping failed: The node is asleep 20:29:33.741 CNTRLR » [Node 012] querying node info... 20:29:33.745 DRIVER The awake timeout for node 13 has elapsed. Assuming it is asleep. 20:29:33.745 CNTRLR [Node 013] The node is now asleep. 20:29:33.747 CNTRLR [Node 013] ping failed: The node is asleep 20:29:33.747 CNTRLR » [Node 013] querying node info... 20:29:33.750 DRIVER The awake timeout for node 15 has elapsed. Assuming it is asleep. 20:29:33.750 CNTRLR [Node 015] The node is now asleep. 20:29:33.751 CNTRLR [Node 015] ping failed: The node is asleep 20:29:33.751 CNTRLR » [Node 015] querying node info... 20:29:33.760 DRIVER The awake timeout for node 16 has elapsed. Assuming it is asleep. 20:29:33.760 CNTRLR [Node 016] The node is now asleep. 20:29:33.761 CNTRLR [Node 016] ping failed: The node is asleep 20:29:33.761 CNTRLR » [Node 016] querying node info... 20:29:33.764 DRIVER The awake timeout for node 17 has elapsed. Assuming it is asleep. 20:29:33.764 CNTRLR [Node 017] The node is now asleep. 20:29:33.765 CNTRLR [Node 017] ping failed: The node is asleep 20:29:33.765 CNTRLR » [Node 017] querying node info... 20:29:33.828 DRIVER The awake timeout for node 25 has elapsed. Assuming it is asleep. 20:29:33.829 CNTRLR [Node 025] The node is now asleep. 20:29:33.830 CNTRLR [Node 025] ping failed: The node is asleep 20:29:33.831 CNTRLR » [Node 025] querying node info... 20:29:33.851 DRIVER The awake timeout for node 32 has elapsed. Assuming it is asleep. 20:29:33.852 CNTRLR [Node 032] The node is now asleep. 20:29:33.861 CNTRLR [Node 032] ping failed: The node is asleep 20:29:33.861 CNTRLR » [Node 032] querying node info... 20:29:34.710 CNTRLR [Node 003] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 20:29:35.217 SERIAL » 0x0109001303029840250a13 (11 bytes) 20:29:35.217 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 10 └─[SecurityCCNonceGet] 20:29:35.218 SERIAL « [ACK] (0x06) 20:29:35.222 SERIAL « 0x0104011301e8 (6 bytes) 20:29:35.223 SERIAL » [ACK] (0x06) 20:29:35.223 DRIVER « [RES] [SendData] was sent: true 20:29:35.242 SERIAL « 0x010700130a000003e2 (9 bytes) 20:29:35.242 SERIAL » [ACK] (0x06) 20:29:35.243 DRIVER « [REQ] [SendData] callback id: 10 transmit status: OK 20:29:36.849 SERIAL » 0x0109001305027204250bba (11 bytes) 20:29:36.850 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 11 └─[ManufacturerSpecificCCGet] 20:29:36.850 CNTRLR [Node 003] The node is not included securely. Continuing interview non-securel y. 20:29:36.853 CNTRLR [Node 003] ManufacturerSpecificCC: doing a complete interview... 20:29:36.853 CNTRLR » [Node 003] querying manufacturer information... 20:29:36.856 SERIAL « [ACK] (0x06) 20:29:36.858 SERIAL « 0x0104011301e8 (6 bytes) 20:29:36.858 SERIAL » [ACK] (0x06) 20:29:36.859 DRIVER « [RES] [SendData] was sent: true 20:29:36.992 SERIAL « 0x010700130b00000eee (9 bytes) 20:29:36.993 SERIAL » [ACK] (0x06) 20:29:36.993 DRIVER « [REQ] [SendData] callback id: 11 transmit status: OK 20:29:37.127 SERIAL « 0x010e00040005087205017500010012e8 (16 bytes) 20:29:37.129 CNTRLR [Node 005] [+] [Manufacturer Specific] manufacturerId: 373 [Endpoint 0] 20:29:37.132 CNTRLR [Node 005] [+] [Manufacturer Specific] productType: 1 [Endpoint 0] 20:29:37.133 CNTRLR [Node 005] [+] [Manufacturer Specific] productId: 18 [Endpoint 0] 20:29:37.134 SERIAL » [ACK] (0x06) 20:29:37.137 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[ManufacturerSpecificCCReport] manufacturer id: 0x0175 product type: 0x01 product id: 0x12 20:29:37.142 SERIAL » 0x0109001306027204250cbe (11 bytes) 20:29:37.142 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 12 └─[ManufacturerSpecificCCGet] 20:29:37.143 CNTRLR « [Node 005] received response for manufacturer information: manufacturer: Devolo (0x0175) product type: 0x01 product id: 0x12 20:29:37.144 CNTRLR [Node 005] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 20:29:37.151 SERIAL « [ACK] (0x06) 20:29:37.153 SERIAL « 0x0104011301e8 (6 bytes) 20:29:37.154 SERIAL » [ACK] (0x06) 20:29:37.155 DRIVER « [RES] [SendData] was sent: true 20:29:37.158 CNTRLR [Node 005] VersionCC: doing a complete interview... 20:29:37.158 CNTRLR » [Node 005] querying node versions... 20:29:37.255 SERIAL « 0x010700130c00000bec (9 bytes) 20:29:37.255 SERIAL » [ACK] (0x06) 20:29:37.256 DRIVER « [REQ] [SendData] callback id: 12 transmit status: OK 20:29:37.265 SERIAL « 0x010e00040006087205017500010012eb (16 bytes) 20:29:37.267 CNTRLR [Node 006] [+] [Manufacturer Specific] manufacturerId: 373 [Endpoint 0] 20:29:37.268 CNTRLR [Node 006] [+] [Manufacturer Specific] productType: 1 [Endpoint 0] 20:29:37.268 CNTRLR [Node 006] [+] [Manufacturer Specific] productId: 18 [Endpoint 0] 20:29:37.269 SERIAL » [ACK] (0x06) 20:29:37.271 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ManufacturerSpecificCCReport] manufacturer id: 0x0175 product type: 0x01 product id: 0x12 20:29:37.275 SERIAL » 0x0109001302027204250dbb (11 bytes) 20:29:37.275 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 13 └─[ManufacturerSpecificCCGet] 20:29:37.276 CNTRLR « [Node 006] received response for manufacturer information: manufacturer: Devolo (0x0175) product type: 0x01 product id: 0x12 20:29:37.276 CNTRLR [Node 006] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 20:29:37.277 CNTRLR [Node 006] VersionCC: doing a complete interview... 20:29:37.277 CNTRLR » [Node 006] querying node versions... 20:29:37.281 SERIAL « [ACK] (0x06) 20:29:37.283 SERIAL « 0x0104011301e8 (6 bytes) 20:29:37.283 SERIAL » [ACK] (0x06) 20:29:37.284 DRIVER « [RES] [SendData] was sent: true 20:29:37.300 SERIAL « 0x010700130d000003e5 (9 bytes) 20:29:37.301 SERIAL » [ACK] (0x06) 20:29:37.301 DRIVER « [REQ] [SendData] callback id: 13 transmit status: OK 20:29:37.328 SERIAL « 0x010e00040002087205017500010011ec (16 bytes) 20:29:37.330 CNTRLR [Node 002] [+] [Manufacturer Specific] manufacturerId: 373 [Endpoint 0] 20:29:37.331 CNTRLR [Node 002] [+] [Manufacturer Specific] productType: 1 [Endpoint 0] 20:29:37.331 CNTRLR [Node 002] [+] [Manufacturer Specific] productId: 17 [Endpoint 0] 20:29:37.332 SERIAL » [ACK] (0x06) 20:29:37.333 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[ManufacturerSpecificCCReport] manufacturer id: 0x0175 product type: 0x01 product id: 0x11 20:29:37.338 SERIAL » 0x01080013130100250edd (10 bytes) 20:29:37.338 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 14 └─[NoOperationCC] 20:29:37.339 CNTRLR « [Node 002] received response for manufacturer information: manufacturer: Devolo (0x0175) product type: 0x01 product id: 0x11 20:29:37.339 CNTRLR [Node 002] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 20:29:37.346 SERIAL « [ACK] (0x06) 20:29:37.348 SERIAL « 0x0104011301e8 (6 bytes) 20:29:37.349 SERIAL » [ACK] (0x06) 20:29:37.350 DRIVER « [RES] [SendData] was sent: true 20:29:37.352 CNTRLR [Node 002] VersionCC: doing a complete interview... 20:29:37.352 CNTRLR » [Node 002] querying node versions... 20:29:37.479 SERIAL « 0x010700130e00000de8 (9 bytes) 20:29:37.480 SERIAL » [ACK] (0x06) 20:29:37.480 DRIVER « [REQ] [SendData] callback id: 14 transmit status: OK 20:29:37.486 SERIAL » 0x01080013120100250fdd (10 bytes) 20:29:37.486 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 15 └─[NoOperationCC] 20:29:37.487 CNTRLR « [Node 019] ping successful 20:29:37.487 CNTRLR » [Node 019] querying node info... 20:29:37.490 SERIAL « [ACK] (0x06) 20:29:37.491 SERIAL « 0x0104011301e8 (6 bytes) 20:29:37.492 SERIAL » [ACK] (0x06) 20:29:37.492 DRIVER « [RES] [SendData] was sent: true 20:29:37.520 SERIAL « 0x010700130f000004e0 (9 bytes) 20:29:37.520 SERIAL » [ACK] (0x06) 20:29:37.521 DRIVER « [REQ] [SendData] callback id: 15 transmit status: OK 20:29:37.524 SERIAL » 0x010800131401002510c4 (10 bytes) 20:29:37.524 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[NoOperationCC] 20:29:37.525 CNTRLR « [Node 018] ping successful 20:29:37.525 CNTRLR » [Node 018] querying node info... 20:29:37.527 SERIAL « [ACK] (0x06) 20:29:37.530 SERIAL « 0x0104011301e8 (6 bytes) 20:29:37.530 SERIAL » [ACK] (0x06) 20:29:37.531 DRIVER « [RES] [SendData] was sent: true 20:29:37.549 SERIAL « 0x0107001310000002f9 (9 bytes) 20:29:37.550 SERIAL » [ACK] (0x06) 20:29:37.551 DRIVER « [REQ] [SendData] callback id: 16 transmit status: OK 20:29:37.565 SERIAL » 0x010800131501002511c4 (10 bytes) 20:29:37.565 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 17 └─[NoOperationCC] 20:29:37.566 CNTRLR « [Node 020] ping successful 20:29:37.566 CNTRLR » [Node 020] querying node info... 20:29:37.569 SERIAL « [ACK] (0x06) 20:29:37.570 SERIAL « 0x0104011301e8 (6 bytes) 20:29:37.571 SERIAL » [ACK] (0x06) 20:29:37.572 DRIVER « [RES] [SendData] was sent: true 20:29:41.561 SERIAL « 0x010c0004001a063105042212a74c (14 bytes) 20:29:41.563 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:29:41.565 CNTRLR [Node 026] [+] [Multilevel Sensor] Power: 477.5 [Endpoint 0] 20:29:41.565 SERIAL » [ACK] (0x06) 20:29:41.566 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 477.5 20:29:41.614 SERIAL « 0x01070013110001956e (9 bytes) 20:29:41.614 SERIAL » [ACK] (0x06) 20:29:41.615 DRIVER « [REQ] [SendData] callback id: 17 transmit status: OK 20:29:41.620 SERIAL » 0x010800131601002512c4 (10 bytes) 20:29:41.621 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 18 └─[NoOperationCC] 20:29:41.621 CNTRLR « [Node 021] ping successful 20:29:41.621 CNTRLR » [Node 021] querying node info... 20:29:41.624 SERIAL « [ACK] (0x06) 20:29:41.626 SERIAL « 0x0104011301e8 (6 bytes) 20:29:41.626 SERIAL » [ACK] (0x06) 20:29:41.627 DRIVER « [RES] [SendData] was sent: true 20:29:41.744 SERIAL « 0x010c0004001c0631050422029d60 (14 bytes) 20:29:41.745 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:29:41.746 CNTRLR [Node 028] [+] [Multilevel Sensor] Power: 66.9 [Endpoint 0] 20:29:41.747 SERIAL » [ACK] (0x06) 20:29:41.748 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 66.9 20:29:43.171 SERIAL « 0x010700131200009b62 (9 bytes) 20:29:43.171 SERIAL » [ACK] (0x06) 20:29:43.172 DRIVER « [REQ] [SendData] callback id: 18 transmit status: OK 20:29:43.176 SERIAL » 0x010800131701002513c4 (10 bytes) 20:29:43.177 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 19 └─[NoOperationCC] 20:29:43.177 CNTRLR « [Node 022] ping successful 20:29:43.177 CNTRLR » [Node 022] querying node info... 20:29:43.178 SERIAL « [ACK] (0x06) 20:29:43.182 SERIAL « 0x0104011301e8 (6 bytes) 20:29:43.182 SERIAL » [ACK] (0x06) 20:29:43.183 DRIVER « [RES] [SendData] was sent: true 20:29:44.456 SERIAL « 0x010700131300008078 (9 bytes) 20:29:44.457 SERIAL » [ACK] (0x06) 20:29:44.457 DRIVER « [REQ] [SendData] callback id: 19 transmit status: OK 20:29:44.462 SERIAL » 0x010800131801002514cc (10 bytes) 20:29:44.463 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 20 └─[NoOperationCC] 20:29:44.463 CNTRLR « [Node 023] ping successful 20:29:44.463 CNTRLR » [Node 023] querying node info... 20:29:44.464 SERIAL « [ACK] (0x06) 20:29:44.468 SERIAL « 0x0104011301e8 (6 bytes) 20:29:44.468 SERIAL » [ACK] (0x06) 20:29:44.469 DRIVER « [RES] [SendData] was sent: true 20:29:45.886 SERIAL « 0x010700131400008e71 (9 bytes) 20:29:45.886 SERIAL » [ACK] (0x06) 20:29:45.887 DRIVER « [REQ] [SendData] callback id: 20 transmit status: OK 20:29:45.894 SERIAL » 0x010800131a01002515cf (10 bytes) 20:29:45.895 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 21 └─[NoOperationCC] 20:29:45.895 CNTRLR « [Node 024] ping successful 20:29:45.895 CNTRLR » [Node 024] querying node info... 20:29:45.899 SERIAL « [ACK] (0x06) 20:29:45.901 SERIAL « 0x0104011301e8 (6 bytes) 20:29:45.901 SERIAL » [ACK] (0x06) 20:29:45.902 DRIVER « [RES] [SendData] was sent: true 20:29:46.036 SERIAL « 0x010700131500000ef0 (9 bytes) 20:29:46.036 SERIAL » [ACK] (0x06) 20:29:46.037 DRIVER « [REQ] [SendData] callback id: 21 transmit status: OK 20:29:46.043 SERIAL » 0x010800131c01002516ca (10 bytes) 20:29:46.044 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 22 └─[NoOperationCC] 20:29:46.044 CNTRLR « [Node 026] ping successful 20:29:46.045 CNTRLR » [Node 026] querying node info... 20:29:46.048 SERIAL « [ACK] (0x06) 20:29:46.050 SERIAL « 0x0104011301e8 (6 bytes) 20:29:46.050 SERIAL » [ACK] (0x06) 20:29:46.051 DRIVER « [RES] [SendData] was sent: true 20:29:46.975 SERIAL « 0x010700131600005da0 (9 bytes) 20:29:46.976 SERIAL » [ACK] (0x06) 20:29:46.976 DRIVER « [REQ] [SendData] callback id: 22 transmit status: OK 20:29:46.979 SERIAL » 0x01090013030272042517a0 (11 bytes) 20:29:46.979 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 23 └─[ManufacturerSpecificCCGet] 20:29:46.979 CNTRLR « [Node 028] ping successful 20:29:46.979 CNTRLR » [Node 028] querying node info... 20:29:46.981 SERIAL « [ACK] (0x06) 20:29:46.984 SERIAL « 0x0104011301e8 (6 bytes) 20:29:46.984 SERIAL » [ACK] (0x06) 20:29:46.985 DRIVER « [RES] [SendData] was sent: true 20:29:47.003 SERIAL « 0x0107001317000002fe (9 bytes) 20:29:47.004 SERIAL » [ACK] (0x06) 20:29:47.004 DRIVER « [REQ] [SendData] callback id: 23 transmit status: OK 20:29:47.017 SERIAL « 0x010e00040003087205010f0602100390 (16 bytes) 20:29:47.018 CNTRLR [Node 003] [+] [Manufacturer Specific] manufacturerId: 271 [Endpoint 0] 20:29:47.019 CNTRLR [Node 003] [+] [Manufacturer Specific] productType: 1538 [Endpoint 0] 20:29:47.019 CNTRLR [Node 003] [+] [Manufacturer Specific] productId: 4099 [Endpoint 0] 20:29:47.020 SERIAL » [ACK] (0x06) 20:29:47.021 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ManufacturerSpecificCCReport] manufacturer id: 0x010f product type: 0x0602 product id: 0x1003 20:29:47.024 SERIAL » 0x0109001305028611251848 (11 bytes) 20:29:47.024 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 24 └─[VersionCCGet] 20:29:47.025 CNTRLR « [Node 003] received response for manufacturer information: manufacturer: Fibargroup (0x010f) product type: 0x0602 product id: 0x1003 20:29:47.025 CNTRLR [Node 003] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 20:29:47.032 SERIAL « [ACK] (0x06) 20:29:47.033 SERIAL « 0x0104011301e8 (6 bytes) 20:29:47.033 SERIAL » [ACK] (0x06) 20:29:47.034 DRIVER « [RES] [SendData] was sent: true 20:29:47.035 CNTRLR [Node 003] VersionCC: doing a complete interview... 20:29:47.036 CNTRLR » [Node 003] querying node versions... 20:29:47.256 SERIAL « 0x010c0004001a063105042208ba4b (14 bytes) 20:29:47.259 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:29:47.260 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 477.5 => 223.4 [Endpoint 0] 20:29:47.262 SERIAL » [ACK] (0x06) 20:29:47.263 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 223.4 20:29:47.641 SERIAL « 0x010700131800003ecd (9 bytes) 20:29:47.642 SERIAL » [ACK] (0x06) 20:29:47.643 DRIVER « [REQ] [SendData] callback id: 24 transmit status: OK 20:29:48.172 SERIAL « 0x010c0004001a06310504220a39ca (14 bytes) 20:29:48.174 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:29:48.175 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 223.4 => 261.7 [Endpoint 0] 20:29:48.175 SERIAL » [ACK] (0x06) 20:29:48.177 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 261.7 20:29:48.502 SERIAL « 0x010f00040005098612030422010e010047 (17 bytes) 20:29:48.504 CNTRLR [Node 005] [+] [Version] libraryType: 3 [Endpoint 0] 20:29:48.505 CNTRLR [Node 005] [+] [Version] protocolVersion: "4.34" [Endpoint 0] 20:29:48.506 CNTRLR [Node 005] [+] [Version] firmwareVersions: 1.14 [Endpoint 0] 20:29:48.506 SERIAL » [ACK] (0x06) 20:29:48.509 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[VersionCCReport] library type: Enhanced Slave protocol version: 4.34 firmware versions: 1.14 20:29:48.514 SERIAL » 0x010900130602861125194a (11 bytes) 20:29:48.515 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 25 └─[VersionCCGet] 20:29:48.515 CNTRLR « [Node 005] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 4.34 firmware versions: 1.14 20:29:48.516 CNTRLR » [Node 005] querying CC versions... 20:29:48.516 CNTRLR » [Node 005] querying the CC version for Binary Switch (0x25)... 20:29:48.525 SERIAL « [ACK] (0x06) 20:29:48.526 SERIAL « 0x0104011301e8 (6 bytes) 20:29:48.526 SERIAL » [ACK] (0x06) 20:29:48.528 DRIVER « [RES] [SendData] was sent: true 20:29:48.543 SERIAL « 0x0107001319000003f1 (9 bytes) 20:29:48.544 SERIAL » [ACK] (0x06) 20:29:48.545 DRIVER « [REQ] [SendData] callback id: 25 transmit status: OK 20:29:48.554 SERIAL « 0x010f00040006098612030422010e010044 (17 bytes) 20:29:48.555 CNTRLR [Node 006] [+] [Version] libraryType: 3 [Endpoint 0] 20:29:48.556 CNTRLR [Node 006] [+] [Version] protocolVersion: "4.34" [Endpoint 0] 20:29:48.557 CNTRLR [Node 006] [+] [Version] firmwareVersions: 1.14 [Endpoint 0] 20:29:48.557 SERIAL » [ACK] (0x06) 20:29:48.559 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCReport] library type: Enhanced Slave protocol version: 4.34 firmware versions: 1.14 20:29:48.563 SERIAL » 0x0109001302028611251a4d (11 bytes) 20:29:48.564 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 26 └─[VersionCCGet] 20:29:48.564 CNTRLR « [Node 006] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 4.34 firmware versions: 1.14 20:29:48.565 CNTRLR » [Node 006] querying CC versions... 20:29:48.565 CNTRLR » [Node 006] querying the CC version for Binary Switch (0x25)... 20:29:48.571 SERIAL « [ACK] (0x06) 20:29:48.572 SERIAL « 0x0104011301e8 (6 bytes) 20:29:48.572 SERIAL » [ACK] (0x06) 20:29:48.573 DRIVER « [RES] [SendData] was sent: true 20:29:48.589 SERIAL « 0x010700131a000002f3 (9 bytes) 20:29:48.589 SERIAL » [ACK] (0x06) 20:29:48.589 DRIVER « [REQ] [SendData] callback id: 26 transmit status: OK 20:29:48.618 SERIAL « 0x0111000400020b8612030353010a0100010a25 (19 bytes) 20:29:48.619 CNTRLR [Node 002] [+] [Version] libraryType: 3 [Endpoint 0] 20:29:48.620 CNTRLR [Node 002] [+] [Version] protocolVersion: "3.83" [Endpoint 0] 20:29:48.620 CNTRLR [Node 002] [+] [Version] firmwareVersions: 1.10 [Endpoint 0] 20:29:48.621 SERIAL » [ACK] (0x06) 20:29:48.622 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[VersionCCReport] library type: Enhanced Slave protocol version: 3.83 firmware versions: 1.10 20:29:48.625 SERIAL » 0x010400601388 (6 bytes) 20:29:48.626 DRIVER » [Node 019] [REQ] [RequestNodeInfo] payload: 0x13 20:29:48.626 CNTRLR « [Node 002] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 3.83 firmware versions: 1.10 20:29:48.626 CNTRLR » [Node 002] querying CC versions... 20:29:48.627 CNTRLR » [Node 002] querying the CC version for Binary Switch (0x25)... 20:29:48.632 SERIAL « [ACK] (0x06) 20:29:48.634 SERIAL « 0x01040160019b (6 bytes) 20:29:48.634 SERIAL » [ACK] (0x06) 20:29:48.635 DRIVER « [RES] [RequestNodeInfo] payload: 0x01 20:29:48.930 SERIAL « 0x011a00498413140410015e22855970565a7a72328e7173983125865a (28 bytes) 20:29:48.931 SERIAL » [ACK] (0x06) 20:29:48.932 DRIVER « [Node 019] [REQ] [ApplicationUpdateRequest] payload: 0x8413140410015e22855970565a7a72328e717398312586 20:29:48.936 SERIAL » 0x010400601289 (6 bytes) 20:29:48.936 DRIVER » [Node 018] [REQ] [RequestNodeInfo] payload: 0x12 20:29:48.936 CNTRLR [Node 019] The node is alive. 20:29:48.937 CNTRLR « [Node 019] node info received supported CCs: · Z-Wave Plus Info · Application Status · Association · Association Group Information · Configuration · CRC-16 Encapsulation · Device Reset Locally · Firmware Update Meta Data · Manufacturer Specific · Meter · Multi Channel Association · Notification · Powerlevel · Security · Multilevel Sensor · Binary Switch · Version controlled CCs: 20:29:48.939 SERIAL « [ACK] (0x06) 20:29:48.940 CNTRLR [Node 019] Interview stage completed: NodeInfo 20:29:48.941 CNTRLR » [Node 019] querying securely supported commands... 20:29:48.943 SERIAL « 0x01040160019b (6 bytes) 20:29:48.943 SERIAL » [ACK] (0x06) 20:29:48.943 DRIVER « [RES] [RequestNodeInfo] payload: 0x01 20:29:49.068 SERIAL « 0x011900498412130410015e86725a7385592571703227752c2b7a59 (27 bytes) 20:29:49.068 SERIAL » [ACK] (0x06) 20:29:49.069 DRIVER « [Node 018] [REQ] [ApplicationUpdateRequest] payload: 0x8412130410015e86725a7385592571703227752c2b7a 20:29:49.081 SERIAL » 0x01040060148f (6 bytes) 20:29:49.082 DRIVER » [Node 020] [REQ] [RequestNodeInfo] payload: 0x14 20:29:49.082 CNTRLR [Node 018] The node is alive. 20:29:49.084 CNTRLR « [Node 018] node info received supported CCs: · Z-Wave Plus Info · Version · Manufacturer Specific · Device Reset Locally · Powerlevel · Association · Association Group Information · Binary Switch · Notification · Configuration · Meter · All Switch · Protection · Scene Actuator Configuration · Scene Activation · Firmware Update Meta Data controlled CCs: 20:29:49.084 CNTRLR [Node 018] Interview stage completed: NodeInfo 20:29:49.086 CNTRLR [Node 018] ManufacturerSpecificCC: doing a complete interview... 20:29:49.086 CNTRLR » [Node 018] querying manufacturer information... 20:29:49.088 SERIAL « [ACK] (0x06) 20:29:49.089 SERIAL « 0x01040160019b (6 bytes) 20:29:49.089 SERIAL » [ACK] (0x06) 20:29:49.089 DRIVER « [RES] [RequestNodeInfo] payload: 0x01 20:29:49.141 SERIAL « 0x011900498414130410015e8672985a855973252027327071757ae0 (27 bytes) 20:29:49.142 SERIAL » [ACK] (0x06) 20:29:49.142 DRIVER « [Node 020] [REQ] [ApplicationUpdateRequest] payload: 0x8414130410015e8672985a855973252027327071757a 20:29:49.147 SERIAL » 0x01040060158e (6 bytes) 20:29:49.148 DRIVER » [Node 021] [REQ] [RequestNodeInfo] payload: 0x15 20:29:49.149 CNTRLR [Node 020] The node is alive. 20:29:49.150 CNTRLR « [Node 020] node info received supported CCs: · Z-Wave Plus Info · Version · Manufacturer Specific · Security · Device Reset Locally · Association · Association Group Information · Powerlevel · Binary Switch · Basic · All Switch · Meter · Configuration · Notification · Protection · Firmware Update Meta Data controlled CCs: 20:29:49.163 SERIAL « [ACK] (0x06) 20:29:49.170 SERIAL « 0x01040160019b (6 bytes) 20:29:49.171 SERIAL » [ACK] (0x06) 20:29:49.172 DRIVER « [RES] [RequestNodeInfo] payload: 0x01 20:29:49.176 CNTRLR [Node 020] Interview stage completed: NodeInfo 20:29:49.177 CNTRLR » [Node 020] querying securely supported commands... 20:29:50.633 SERIAL « 0x011d00498415170408065e855986725a753126404380707173989f556c7adc (31 bytes) 20:29:50.634 SERIAL » [ACK] (0x06) 20:29:50.635 DRIVER « [Node 021] [REQ] [ApplicationUpdateRequest] payload: 0x8415170408065e855986725a753126404380707173989f556c7a 20:29:50.637 SERIAL » 0x01040060168d (6 bytes) 20:29:50.637 DRIVER » [Node 022] [REQ] [RequestNodeInfo] payload: 0x16 20:29:50.638 CNTRLR [Node 021] The node is alive. 20:29:50.638 CNTRLR « [Node 021] node info received supported CCs: · Z-Wave Plus Info · Association · Association Group Information · Version · Manufacturer Specific · Device Reset Locally · Protection · Multilevel Sensor · Multilevel Switch · Thermostat Mode · Thermostat Setpoint · Battery · Configuration · Notification · Powerlevel · Security · Security 2 · Transport Service · Supervision · Firmware Update Meta Data controlled CCs: 20:29:50.641 SERIAL « [ACK] (0x06) 20:29:50.643 CNTRLR [Node 021] Interview stage completed: NodeInfo 20:29:50.643 CNTRLR » [Node 021] querying securely supported commands... 20:29:50.644 SERIAL « 0x01040160019b (6 bytes) 20:29:50.644 SERIAL » [ACK] (0x06) 20:29:50.645 DRIVER « [RES] [RequestNodeInfo] payload: 0x01 20:29:52.210 SERIAL « 0x011d00498416170408065e855986725a753126404380707173989f556c7adf (31 bytes) 20:29:52.210 SERIAL » [ACK] (0x06) 20:29:52.211 DRIVER « [Node 022] [REQ] [ApplicationUpdateRequest] payload: 0x8416170408065e855986725a753126404380707173989f556c7a 20:29:52.217 SERIAL » 0x01040060178c (6 bytes) 20:29:52.218 DRIVER » [Node 023] [REQ] [RequestNodeInfo] payload: 0x17 20:29:52.219 CNTRLR [Node 022] The node is alive. 20:29:52.221 CNTRLR « [Node 022] node info received supported CCs: · Z-Wave Plus Info · Association · Association Group Information · Version · Manufacturer Specific · Device Reset Locally · Protection · Multilevel Sensor · Multilevel Switch · Thermostat Mode · Thermostat Setpoint · Battery · Configuration · Notification · Powerlevel · Security · Security 2 · Transport Service · Supervision · Firmware Update Meta Data controlled CCs: 20:29:52.229 SERIAL « [ACK] (0x06) 20:29:52.232 SERIAL « 0x01040160019b (6 bytes) 20:29:52.232 SERIAL » [ACK] (0x06) 20:29:52.233 DRIVER « [RES] [RequestNodeInfo] payload: 0x01 20:29:52.243 CNTRLR [Node 022] Interview stage completed: NodeInfo 20:29:52.244 CNTRLR » [Node 022] querying securely supported commands... 20:29:53.548 SERIAL « 0x011d00498417170408065e855986725a753126404380707173989f556c7ade (31 bytes) 20:29:53.549 SERIAL » [ACK] (0x06) 20:29:53.550 DRIVER « [Node 023] [REQ] [ApplicationUpdateRequest] payload: 0x8417170408065e855986725a753126404380707173989f556c7a 20:29:53.553 SERIAL » 0x010400601883 (6 bytes) 20:29:53.553 DRIVER » [Node 024] [REQ] [RequestNodeInfo] payload: 0x18 20:29:53.553 CNTRLR [Node 023] The node is alive. 20:29:53.554 CNTRLR « [Node 023] node info received supported CCs: · Z-Wave Plus Info · Association · Association Group Information · Version · Manufacturer Specific · Device Reset Locally · Protection · Multilevel Sensor · Multilevel Switch · Thermostat Mode · Thermostat Setpoint · Battery · Configuration · Notification · Powerlevel · Security · Security 2 · Transport Service · Supervision · Firmware Update Meta Data controlled CCs: 20:29:53.556 SERIAL « [ACK] (0x06) 20:29:53.558 SERIAL « 0x01040160019b (6 bytes) 20:29:53.558 SERIAL » [ACK] (0x06) 20:29:53.559 DRIVER « [RES] [RequestNodeInfo] payload: 0x01 20:29:53.560 CNTRLR [Node 023] Interview stage completed: NodeInfo 20:29:53.560 CNTRLR » [Node 023] querying securely supported commands... 20:29:55.036 SERIAL « 0x011d00498418170408065e855986725a753126404380707173989f556c7ad1 (31 bytes) 20:29:55.037 SERIAL » [ACK] (0x06) 20:29:55.038 DRIVER « [Node 024] [REQ] [ApplicationUpdateRequest] payload: 0x8418170408065e855986725a753126404380707173989f556c7a 20:29:55.041 SERIAL » 0x010400601a81 (6 bytes) 20:29:55.042 DRIVER » [Node 026] [REQ] [RequestNodeInfo] payload: 0x1a 20:29:55.042 CNTRLR [Node 024] The node is alive. 20:29:55.042 CNTRLR « [Node 024] node info received supported CCs: · Z-Wave Plus Info · Association · Association Group Information · Version · Manufacturer Specific · Device Reset Locally · Protection · Multilevel Sensor · Multilevel Switch · Thermostat Mode · Thermostat Setpoint · Battery · Configuration · Notification · Powerlevel · Security · Security 2 · Transport Service · Supervision · Firmware Update Meta Data controlled CCs: 20:29:55.046 SERIAL « [ACK] (0x06) 20:29:55.047 CNTRLR [Node 024] Interview stage completed: NodeInfo 20:29:55.047 CNTRLR » [Node 024] querying securely supported commands... 20:29:55.049 SERIAL « 0x01040160019b (6 bytes) 20:29:55.049 SERIAL » [ACK] (0x06) 20:29:55.049 DRIVER « [RES] [RequestNodeInfo] payload: 0x01 20:29:55.411 SERIAL « 0x011a0049841a140410015e22855970565a7a72328e71739831258653 (28 bytes) 20:29:55.411 SERIAL » [ACK] (0x06) 20:29:55.412 DRIVER « [Node 026] [REQ] [ApplicationUpdateRequest] payload: 0x841a140410015e22855970565a7a72328e717398312586 20:29:55.417 SERIAL » 0x010400601c87 (6 bytes) 20:29:55.417 DRIVER » [Node 028] [REQ] [RequestNodeInfo] payload: 0x1c 20:29:55.418 CNTRLR [Node 026] The node is alive. 20:29:55.419 CNTRLR « [Node 026] node info received supported CCs: · Z-Wave Plus Info · Application Status · Association · Association Group Information · Configuration · CRC-16 Encapsulation · Device Reset Locally · Firmware Update Meta Data · Manufacturer Specific · Meter · Multi Channel Association · Notification · Powerlevel · Security · Multilevel Sensor · Binary Switch · Version controlled CCs: 20:29:55.424 SERIAL « [ACK] (0x06) 20:29:55.427 SERIAL « 0x01040160019b (6 bytes) 20:29:55.428 SERIAL » [ACK] (0x06) 20:29:55.429 DRIVER « [RES] [RequestNodeInfo] payload: 0x01 20:29:55.433 CNTRLR [Node 026] Interview stage completed: NodeInfo 20:29:55.433 CNTRLR » [Node 026] querying securely supported commands... 20:29:55.558 SERIAL « 0x011a0049841c140410015e22855970565a7a72328e71739831258655 (28 bytes) 20:29:55.559 SERIAL » [ACK] (0x06) 20:29:55.559 DRIVER « [Node 028] [REQ] [ApplicationUpdateRequest] payload: 0x841c140410015e22855970565a7a72328e717398312586 20:29:55.568 SERIAL » 0x0109001303028611251b4d (11 bytes) 20:29:55.568 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 27 └─[VersionCCGet] 20:29:55.569 CNTRLR [Node 028] The node is alive. 20:29:55.570 CNTRLR « [Node 028] node info received supported CCs: · Z-Wave Plus Info · Application Status · Association · Association Group Information · Configuration · CRC-16 Encapsulation · Device Reset Locally · Firmware Update Meta Data · Manufacturer Specific · Meter · Multi Channel Association · Notification · Powerlevel · Security · Multilevel Sensor · Binary Switch · Version controlled CCs: 20:29:55.571 CNTRLR [Node 028] Interview stage completed: NodeInfo 20:29:55.574 CNTRLR » [Node 028] querying securely supported commands... 20:29:55.578 SERIAL « [ACK] (0x06) 20:29:55.579 SERIAL « 0x0104011301e8 (6 bytes) 20:29:55.580 SERIAL » [ACK] (0x06) 20:29:55.580 DRIVER « [RES] [SendData] was sent: true 20:29:55.594 SERIAL « 0x010700131b000002f2 (9 bytes) 20:29:55.594 SERIAL » [ACK] (0x06) 20:29:55.595 DRIVER « [REQ] [SendData] callback id: 27 transmit status: OK 20:29:55.608 SERIAL « 0x0111000400030b86120304180302020103026a (19 bytes) 20:29:55.609 CNTRLR [Node 003] [+] [Version] libraryType: 3 [Endpoint 0] 20:29:55.610 CNTRLR [Node 003] [+] [Version] protocolVersion: "4.24" [Endpoint 0] 20:29:55.611 CNTRLR [Node 003] [+] [Version] firmwareVersions: 3.2 [Endpoint 0] 20:29:55.611 SERIAL » [ACK] (0x06) 20:29:55.612 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[VersionCCReport] library type: Enhanced Slave protocol version: 4.24 firmware versions: 3.2 20:29:55.614 SERIAL » 0x010a00130503861325251c69 (12 bytes) 20:29:55.615 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 28 └─[VersionCCCommandClassGet] CC: Binary Switch 20:29:55.615 CNTRLR « [Node 003] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 4.24 firmware versions: 3.2 20:29:55.615 CNTRLR » [Node 003] querying CC versions... 20:29:55.615 CNTRLR » [Node 003] querying the CC version for Binary Switch (0x25)... 20:29:55.618 SERIAL « [ACK] (0x06) 20:29:55.622 SERIAL « 0x0104011301e8 (6 bytes) 20:29:55.622 SERIAL » [ACK] (0x06) 20:29:55.623 DRIVER « [RES] [SendData] was sent: true 20:29:55.638 SERIAL « 0x010700131c000002f5 (9 bytes) 20:29:55.638 SERIAL » [ACK] (0x06) 20:29:55.638 DRIVER « [REQ] [SendData] callback id: 28 transmit status: OK 20:29:55.647 SERIAL « 0x010a00040005048614250146 (12 bytes) 20:29:55.648 SERIAL » [ACK] (0x06) 20:29:55.649 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Binary Switch version: 1 20:29:55.650 SERIAL » 0x010a00130603861325251d6b (12 bytes) 20:29:55.651 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 29 └─[VersionCCCommandClassGet] CC: Binary Switch 20:29:55.651 CNTRLR [Node 005] supports CC Binary Switch (0x25) in version 1 20:29:55.651 CNTRLR [Node 005] skipping query for All Switch (0x27) because max implemented vers ion is 0 20:29:55.651 CNTRLR » [Node 005] querying the CC version for Z-Wave Plus Info (0x5e)... 20:29:55.653 SERIAL « [ACK] (0x06) 20:29:55.656 SERIAL « 0x0104011301e8 (6 bytes) 20:29:55.656 SERIAL » [ACK] (0x06) 20:29:55.657 DRIVER « [RES] [SendData] was sent: true 20:29:55.671 SERIAL « 0x010700131d000002f4 (9 bytes) 20:29:55.671 SERIAL » [ACK] (0x06) 20:29:55.672 DRIVER « [REQ] [SendData] callback id: 29 transmit status: OK 20:29:55.681 SERIAL « 0x010a00040006048614250145 (12 bytes) 20:29:55.681 SERIAL » [ACK] (0x06) 20:29:55.682 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Binary Switch version: 1 20:29:55.685 SERIAL » 0x010a00130203861325251e6c (12 bytes) 20:29:55.685 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 30 └─[VersionCCCommandClassGet] CC: Binary Switch 20:29:55.686 CNTRLR [Node 006] supports CC Binary Switch (0x25) in version 1 20:29:55.686 CNTRLR [Node 006] skipping query for All Switch (0x27) because max implemented vers ion is 0 20:29:55.686 CNTRLR » [Node 006] querying the CC version for Z-Wave Plus Info (0x5e)... 20:29:55.689 SERIAL « [ACK] (0x06) 20:29:55.691 SERIAL « 0x0104011301e8 (6 bytes) 20:29:55.691 SERIAL » [ACK] (0x06) 20:29:55.691 DRIVER « [RES] [SendData] was sent: true 20:29:55.710 SERIAL « 0x010700131e000003f6 (9 bytes) 20:29:55.711 SERIAL » [ACK] (0x06) 20:29:55.711 DRIVER « [REQ] [SendData] callback id: 30 transmit status: OK 20:29:55.738 SERIAL « 0x010a00040002048614250141 (12 bytes) 20:29:55.738 SERIAL » [ACK] (0x06) 20:29:55.739 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Binary Switch version: 1 20:29:55.742 SERIAL » 0x0109001313029840251f16 (11 bytes) 20:29:55.743 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 31 └─[SecurityCCNonceGet] 20:29:55.743 CNTRLR [Node 002] supports CC Binary Switch (0x25) in version 1 20:29:55.743 CNTRLR [Node 002] skipping query for All Switch (0x27) because max implemented vers ion is 0 20:29:55.743 CNTRLR » [Node 002] querying the CC version for Z-Wave Plus Info (0x5e)... 20:29:55.745 SERIAL « [ACK] (0x06) 20:29:55.748 SERIAL « 0x0104011301e8 (6 bytes) 20:29:55.748 SERIAL » [ACK] (0x06) 20:29:55.748 DRIVER « [RES] [SendData] was sent: true 20:29:55.885 SERIAL « 0x010700131f00000efa (9 bytes) 20:29:55.886 SERIAL » [ACK] (0x06) 20:29:55.887 DRIVER « [REQ] [SendData] callback id: 31 transmit status: OK 20:29:57.490 CNTRLR [Node 019] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 20:29:57.996 SERIAL » 0x0109001313029840252029 (11 bytes) 20:29:57.997 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 32 └─[SecurityCCNonceGet] 20:29:57.998 SERIAL « [ACK] (0x06) 20:29:58.002 SERIAL « 0x0104011301e8 (6 bytes) 20:29:58.003 SERIAL » [ACK] (0x06) 20:29:58.004 DRIVER « [RES] [SendData] was sent: true 20:29:58.140 SERIAL « 0x010700132000000ec5 (9 bytes) 20:29:58.140 SERIAL » [ACK] (0x06) 20:29:58.141 DRIVER « [REQ] [SendData] callback id: 32 transmit status: OK 20:29:59.744 CNTRLR [Node 019] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 20:30:00.251 SERIAL » 0x0109001313029840252128 (11 bytes) 20:30:00.251 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 33 └─[SecurityCCNonceGet] 20:30:00.255 SERIAL « [ACK] (0x06) 20:30:00.256 SERIAL « 0x0104011301e8 (6 bytes) 20:30:00.257 SERIAL » [ACK] (0x06) 20:30:00.257 DRIVER « [RES] [SendData] was sent: true 20:30:00.396 SERIAL « 0x010700132100000ec4 (9 bytes) 20:30:00.396 SERIAL » [ACK] (0x06) 20:30:00.397 DRIVER « [REQ] [SendData] callback id: 33 transmit status: OK 20:30:02.003 SERIAL » 0x0109001312027204252284 (11 bytes) 20:30:02.004 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 34 └─[ManufacturerSpecificCCGet] 20:30:02.004 CNTRLR [Node 019] The node is not included securely. Continuing interview non-securel y. 20:30:02.006 CNTRLR [Node 019] ManufacturerSpecificCC: doing a complete interview... 20:30:02.007 CNTRLR » [Node 019] querying manufacturer information... 20:30:02.010 SERIAL « [ACK] (0x06) 20:30:02.011 SERIAL « 0x0104011301e8 (6 bytes) 20:30:02.011 SERIAL » [ACK] (0x06) 20:30:02.012 DRIVER « [RES] [SendData] was sent: true 20:30:02.024 SERIAL « 0x0107001322000002cb (9 bytes) 20:30:02.025 SERIAL » [ACK] (0x06) 20:30:02.026 DRIVER « [REQ] [SendData] callback id: 34 transmit status: OK 20:30:02.035 SERIAL « 0x010e00040012087205017500010012ff (16 bytes) 20:30:02.036 CNTRLR [Node 018] [+] [Manufacturer Specific] manufacturerId: 373 [Endpoint 0] 20:30:02.037 CNTRLR [Node 018] [+] [Manufacturer Specific] productType: 1 [Endpoint 0] 20:30:02.037 CNTRLR [Node 018] [+] [Manufacturer Specific] productId: 18 [Endpoint 0] 20:30:02.038 SERIAL » [ACK] (0x06) 20:30:02.039 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[ManufacturerSpecificCCReport] manufacturer id: 0x0175 product type: 0x01 product id: 0x12 20:30:02.045 SERIAL » 0x010900131402984025232d (11 bytes) 20:30:02.046 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 35 └─[SecurityCCNonceGet] 20:30:02.046 CNTRLR « [Node 018] received response for manufacturer information: manufacturer: Devolo (0x0175) product type: 0x01 product id: 0x12 20:30:02.047 CNTRLR [Node 018] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 20:30:02.053 SERIAL « [ACK] (0x06) 20:30:02.059 SERIAL « 0x0104011301e8 (6 bytes) 20:30:02.059 SERIAL » [ACK] (0x06) 20:30:02.060 DRIVER « [RES] [SendData] was sent: true 20:30:02.062 CNTRLR [Node 018] VersionCC: doing a complete interview... 20:30:02.062 CNTRLR » [Node 018] querying node versions... 20:30:02.070 SERIAL « 0x0107001323000003cb (9 bytes) 20:30:02.070 SERIAL » [ACK] (0x06) 20:30:02.071 DRIVER « [REQ] [SendData] callback id: 35 transmit status: OK 20:30:02.963 SERIAL « 0x010c0004001a063105042211a149 (14 bytes) 20:30:02.964 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:30:02.965 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 261.7 => 451.3 [Endpoint 0] 20:30:02.965 SERIAL » [ACK] (0x06) 20:30:02.967 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 451.3 20:30:03.677 CNTRLR [Node 020] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 20:30:03.962 SERIAL « 0x010c0004001a06310504220955a5 (14 bytes) 20:30:03.964 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:30:03.965 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 451.3 => 238.9 [Endpoint 0] 20:30:03.965 SERIAL » [ACK] (0x06) 20:30:03.966 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 238.9 20:30:04.182 SERIAL » 0x010900131402984025242a (11 bytes) 20:30:04.182 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 36 └─[SecurityCCNonceGet] 20:30:04.184 SERIAL « [ACK] (0x06) 20:30:04.188 SERIAL « 0x0104011301e8 (6 bytes) 20:30:04.188 SERIAL » [ACK] (0x06) 20:30:04.189 DRIVER « [RES] [SendData] was sent: true 20:30:04.207 SERIAL « 0x0107001324000002cd (9 bytes) 20:30:04.208 SERIAL » [ACK] (0x06) 20:30:04.209 DRIVER « [REQ] [SendData] callback id: 36 transmit status: OK 20:30:05.812 CNTRLR [Node 020] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 20:30:06.317 SERIAL » 0x010900131402984025252b (11 bytes) 20:30:06.317 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 37 └─[SecurityCCNonceGet] 20:30:06.318 SERIAL « [ACK] (0x06) 20:30:06.322 SERIAL « 0x0104011301e8 (6 bytes) 20:30:06.322 SERIAL » [ACK] (0x06) 20:30:06.323 DRIVER « [RES] [SendData] was sent: true 20:30:06.341 SERIAL « 0x0107001325000003cd (9 bytes) 20:30:06.342 SERIAL » [ACK] (0x06) 20:30:06.343 DRIVER « [REQ] [SendData] callback id: 37 transmit status: OK 20:30:06.963 SERIAL « 0x010c0004001a063105042213ca20 (14 bytes) 20:30:06.964 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:30:06.965 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 238.9 => 506.6 [Endpoint 0] 20:30:06.965 SERIAL » [ACK] (0x06) 20:30:06.966 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 506.6 20:30:07.949 SERIAL » 0x0109001315029840252629 (11 bytes) 20:30:07.949 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 38 └─[SecurityCCNonceGet] 20:30:07.950 CNTRLR [Node 020] The node is not included securely. Continuing interview non-securel y. 20:30:07.950 CNTRLR [Node 020] ManufacturerSpecificCC: doing a complete interview... 20:30:07.950 CNTRLR » [Node 020] querying manufacturer information... 20:30:07.952 SERIAL « [ACK] (0x06) 20:30:07.955 SERIAL « 0x0104011301e8 (6 bytes) 20:30:07.955 SERIAL » [ACK] (0x06) 20:30:07.955 DRIVER « [RES] [SendData] was sent: true 20:30:09.338 SERIAL « 0x010700132600008a47 (9 bytes) 20:30:09.338 SERIAL » [ACK] (0x06) 20:30:09.339 DRIVER « [REQ] [SendData] callback id: 38 transmit status: OK 20:30:09.421 SERIAL « 0x0110000400150a9880a5b0499e1867740124 (18 bytes) 20:30:09.423 SERIAL » [ACK] (0x06) 20:30:09.424 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xa5b0499e18677401 20:30:09.427 SERIAL » 0x011d0013151698810f94750ddf886fee571153a5f2450b8576f2a730252746 (31 bytes) 20:30:09.428 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[SecurityCCCommandEncapsulation] │ nonce id: 165 └─[SecurityCCCommandsSupportedGet] 20:30:09.430 SERIAL « [ACK] (0x06) 20:30:09.434 SERIAL « 0x0104011301e8 (6 bytes) 20:30:09.434 SERIAL » [ACK] (0x06) 20:30:09.434 DRIVER « [RES] [SendData] was sent: true 20:30:09.551 SERIAL « 0x010700132700000cc0 (9 bytes) 20:30:09.552 SERIAL » [ACK] (0x06) 20:30:09.553 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 20:30:11.156 CNTRLR [Node 021] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 20:30:11.662 SERIAL » 0x0109001315029840252827 (11 bytes) 20:30:11.663 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 40 └─[SecurityCCNonceGet] 20:30:11.664 SERIAL « [ACK] (0x06) 20:30:11.668 SERIAL « 0x0104011301e8 (6 bytes) 20:30:11.668 SERIAL » [ACK] (0x06) 20:30:11.668 DRIVER « [RES] [SendData] was sent: true 20:30:14.240 SERIAL « 0x0107001328000101c3 (9 bytes) 20:30:14.240 SERIAL » [ACK] (0x06) 20:30:14.241 DRIVER « [REQ] [SendData] callback id: 40 transmit status: OK 20:30:14.321 SERIAL « 0x0110000400150a9880d7032ea5aa205e2641 (18 bytes) 20:30:14.322 SERIAL » [ACK] (0x06) 20:30:14.323 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xd7032ea5aa205e26 20:30:14.327 SERIAL » 0x011d0013151698815674f78ff2d51d4948f6fbd7cb1f7af61c4ad0df252753 (31 bytes) 20:30:14.327 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[SecurityCCCommandEncapsulation] │ nonce id: 215 └─[SecurityCCCommandsSupportedGet] 20:30:14.330 SERIAL « [ACK] (0x06) 20:30:14.334 SERIAL « 0x0104011301e8 (6 bytes) 20:30:14.335 SERIAL » [ACK] (0x06) 20:30:14.336 DRIVER « [RES] [SendData] was sent: true 20:30:14.460 SERIAL « 0x010700132700000cc0 (9 bytes) 20:30:14.460 SERIAL » [ACK] (0x06) 20:30:14.461 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 20:30:16.064 CNTRLR [Node 021] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 20:30:16.574 SERIAL » 0x0109001315029840252926 (11 bytes) 20:30:16.574 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 41 └─[SecurityCCNonceGet] 20:30:16.575 SERIAL « [ACK] (0x06) 20:30:16.579 SERIAL « 0x0104011301e8 (6 bytes) 20:30:16.580 SERIAL » [ACK] (0x06) 20:30:16.580 DRIVER « [RES] [SendData] was sent: true 20:30:18.051 SERIAL « 0x010c0004001a06310504220a6794 (14 bytes) 20:30:18.053 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:30:18.054 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 506.6 => 266.3 [Endpoint 0] 20:30:18.054 SERIAL » [ACK] (0x06) 20:30:18.055 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 266.3 20:30:19.216 SERIAL « 0x010c0004001a06310504220a6794 (14 bytes) 20:30:19.217 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:30:19.218 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 266.3 => 266.3 [Endpoint 0] 20:30:19.219 SERIAL » [ACK] (0x06) 20:30:19.220 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 266.3 20:30:20.383 SERIAL « 0x010c0004001a06310504220a6794 (14 bytes) 20:30:20.384 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:30:20.385 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 266.3 => 266.3 [Endpoint 0] 20:30:20.386 SERIAL » [ACK] (0x06) 20:30:20.387 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 266.3 20:30:20.711 SERIAL « 0x010c0004001a06310504220a6794 (14 bytes) 20:30:20.712 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:30:20.713 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 266.3 => 266.3 [Endpoint 0] 20:30:20.714 SERIAL » [ACK] (0x06) 20:30:20.715 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 266.3 20:30:21.062 SERIAL « 0x0110000410150a9880de3333725652730423 (18 bytes) 20:30:21.062 SERIAL » [ACK] (0x06) 20:30:21.063 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xde33337256527304 20:30:21.089 SERIAL « 0x01070013290001c300 (9 bytes) 20:30:21.089 SERIAL » [ACK] (0x06) 20:30:21.090 DRIVER « [REQ] [SendData] callback id: 41 transmit status: OK 20:30:21.219 SERIAL « 0x0110000410150a9880de3333725652730423 (18 bytes) 20:30:21.220 SERIAL » [ACK] (0x06) 20:30:21.221 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xde33337256527304 20:30:21.225 SERIAL » 0x011d001315169881ff270f81db914b1689d01ede5bce4c506664817e252745 (31 bytes) 20:30:21.226 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[SecurityCCCommandEncapsulation] │ nonce id: 222 └─[SecurityCCCommandsSupportedGet] 20:30:21.228 SERIAL « [ACK] (0x06) 20:30:21.234 SERIAL « 0x0104011301e8 (6 bytes) 20:30:21.234 SERIAL » [ACK] (0x06) 20:30:21.235 DRIVER « [RES] [SendData] was sent: true 20:30:23.872 SERIAL « 0x010c0004001a063105042208cf3e (14 bytes) 20:30:23.873 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:30:23.874 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 266.3 => 225.5 [Endpoint 0] 20:30:23.874 SERIAL » [ACK] (0x06) 20:30:23.876 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 225.5 20:30:25.194 SERIAL « 0x010c0004001a063105042210ad44 (14 bytes) 20:30:25.195 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:30:25.196 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 225.5 => 426.9 [Endpoint 0] 20:30:25.197 SERIAL » [ACK] (0x06) 20:30:25.198 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 426.9 20:30:25.579 SERIAL « 0x010c0004001a06310504220a887b (14 bytes) 20:30:25.580 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:30:25.581 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 426.9 => 269.6 [Endpoint 0] 20:30:25.581 SERIAL » [ACK] (0x06) 20:30:25.583 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 269.6 20:30:26.091 SERIAL « 0x010c0004001a06310504220a887b (14 bytes) 20:30:26.092 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:30:26.093 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 269.6 => 269.6 [Endpoint 0] 20:30:26.093 SERIAL » [ACK] (0x06) 20:30:26.095 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 269.6 20:30:26.991 SERIAL « 0x010c0004001a0631050422064cb3 (14 bytes) 20:30:26.992 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:30:26.993 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 269.6 => 161.2 [Endpoint 0] 20:30:26.994 SERIAL » [ACK] (0x06) 20:30:26.995 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 161.2 20:30:28.696 SERIAL « 0x010c0004001a063105042211af47 (14 bytes) 20:30:28.697 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:30:28.698 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 161.2 => 452.7 [Endpoint 0] 20:30:28.698 SERIAL » [ACK] (0x06) 20:30:28.700 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 452.7 20:30:33.863 SERIAL « 0x01070013270004f038 (9 bytes) 20:30:33.864 SERIAL » [ACK] (0x06) 20:30:33.867 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 20:30:35.477 SERIAL » 0x0109001316029840252a26 (11 bytes) 20:30:35.477 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 42 └─[SecurityCCNonceGet] 20:30:35.478 CNTRLR [Node 021] The node is not included securely. Continuing interview non-securel y. 20:30:35.480 CNTRLR [Node 021] ManufacturerSpecificCC: doing a complete interview... 20:30:35.480 CNTRLR » [Node 021] querying manufacturer information... 20:30:35.483 SERIAL « [ACK] (0x06) 20:30:35.484 SERIAL « 0x0104011301e8 (6 bytes) 20:30:35.484 SERIAL » [ACK] (0x06) 20:30:35.485 DRIVER « [RES] [SendData] was sent: true 20:30:36.847 SERIAL « 0x010c0004001c06310504220221dc (14 bytes) 20:30:36.848 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:30:36.849 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 66.9 => 54.5 [Endpoint 0] 20:30:36.850 SERIAL » [ACK] (0x06) 20:30:36.851 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 54.5 20:30:36.870 SERIAL « 0x010700132a00008b4a (9 bytes) 20:30:36.871 SERIAL » [ACK] (0x06) 20:30:36.872 DRIVER « [REQ] [SendData] callback id: 42 transmit status: OK 20:30:36.949 SERIAL « 0x0110000400160a9880ca3f0f833ac9927384 (18 bytes) 20:30:36.951 SERIAL » [ACK] (0x06) 20:30:36.952 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xca3f0f833ac99273 20:30:36.957 SERIAL » 0x011d0013161698817b65706a639877f885d477ca743b58ca3b527687252b3f (31 bytes) 20:30:36.957 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 43 └─[SecurityCCCommandEncapsulation] │ nonce id: 202 └─[SecurityCCCommandsSupportedGet] 20:30:36.960 SERIAL « [ACK] (0x06) 20:30:36.964 SERIAL « 0x0104011301e8 (6 bytes) 20:30:36.965 SERIAL » [ACK] (0x06) 20:30:36.966 DRIVER « [RES] [SendData] was sent: true 20:30:37.081 SERIAL « 0x010700132b00000ccc (9 bytes) 20:30:37.082 SERIAL » [ACK] (0x06) 20:30:37.083 DRIVER « [REQ] [SendData] callback id: 43 transmit status: OK 20:30:38.695 CNTRLR [Node 022] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 20:30:39.202 SERIAL » 0x0109001316029840252c20 (11 bytes) 20:30:39.203 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 44 └─[SecurityCCNonceGet] 20:30:39.204 SERIAL « [ACK] (0x06) 20:30:39.208 SERIAL « 0x0104011301e8 (6 bytes) 20:30:39.209 SERIAL » [ACK] (0x06) 20:30:39.210 DRIVER « [RES] [SendData] was sent: true 20:30:40.556 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:30:40.559 CNTRLR [Node 005] [Meter] value[66049]: metadata updated [Endpoint 0] 20:30:40.560 CNTRLR [Node 005] [+] [Meter] value[66049]: 0 [Endpoint 0] 20:30:40.560 CNTRLR [Node 005] [+] [Meter] deltaTime[66049]: 0 [Endpoint 0] 20:30:40.561 SERIAL » [ACK] (0x06) 20:30:40.562 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:30:40.579 SERIAL « 0x010700132c0000894e (9 bytes) 20:30:40.579 SERIAL » [ACK] (0x06) 20:30:40.579 DRIVER « [REQ] [SendData] callback id: 44 transmit status: OK 20:30:40.637 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:30:40.638 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:30:40.639 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:30:40.640 SERIAL » [ACK] (0x06) 20:30:40.641 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:30:40.668 SERIAL « 0x0110000400160a9880ea9410a9f008f6a284 (18 bytes) 20:30:40.669 SERIAL » [ACK] (0x06) 20:30:40.671 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xea9410a9f008f6a2 20:30:40.682 SERIAL » 0x011d001316169881788e2f88091d2e02f797e0ea86c27906946d150b252b39 (31 bytes) 20:30:40.683 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 43 └─[SecurityCCCommandEncapsulation] │ nonce id: 234 └─[SecurityCCCommandsSupportedGet] 20:30:40.685 SERIAL « [ACK] (0x06) 20:30:40.689 SERIAL « 0x0104011301e8 (6 bytes) 20:30:40.690 SERIAL » [ACK] (0x06) 20:30:40.691 DRIVER « [RES] [SendData] was sent: true 20:30:40.812 SERIAL « 0x010700132b00000dcd (9 bytes) 20:30:40.812 SERIAL » [ACK] (0x06) 20:30:40.813 DRIVER « [REQ] [SendData] callback id: 43 transmit status: OK 20:30:42.417 CNTRLR [Node 022] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 20:30:42.784 SERIAL « 0x0109000400110380035a39 (11 bytes) 20:30:42.785 CNTRLR [Node 017] [+] [Battery] level: 90 [Endpoint 0] 20:30:42.786 CNTRLR [Node 017] [+] [Battery] isLow: false [Endpoint 0] 20:30:42.787 SERIAL » [ACK] (0x06) 20:30:42.789 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 90 is low: false 20:30:42.819 SERIAL « 0x010c0004001c063105042202a05d (14 bytes) 20:30:42.820 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:30:42.821 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 54.5 => 67.2 [Endpoint 0] 20:30:42.822 SERIAL » [ACK] (0x06) 20:30:42.823 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 67.2 20:30:42.841 SERIAL « 0x010c000400110643030142076c88 (14 bytes) 20:30:42.847 CNTRLR [Node 017] [Thermostat Setpoint] setpoint[1]: metadata updated [Endpoint 0] 20:30:42.848 CNTRLR [Node 017] [+] [Thermostat Setpoint] setpoint[1]: 19 [Endpoint 0] 20:30:42.849 CNTRLR [Node 017] [+] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 20:30:42.849 SERIAL » [ACK] (0x06) 20:30:42.851 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 20:30:42.903 SERIAL « 0x010a00040011044608007fd5 (12 bytes) 20:30:42.905 CNTRLR [Node 017] [+] [Climate Control Schedule] overrideType: 0 [Endpoint 0] 20:30:42.906 CNTRLR [Node 017] [+] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] 20:30:42.906 SERIAL » [ACK] (0x06) 20:30:42.908 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ClimateControlScheduleCCOverrideReport] override type: None override state: Unused 20:30:42.924 SERIAL » 0x0109001316029840252d21 (11 bytes) 20:30:42.925 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 45 └─[SecurityCCNonceGet] 20:30:42.926 SERIAL « [ACK] (0x06) 20:30:42.931 SERIAL « 0x0104011301e8 (6 bytes) 20:30:42.932 SERIAL » [ACK] (0x06) 20:30:42.933 DRIVER « [RES] [SendData] was sent: true 20:30:44.385 SERIAL « 0x01080004001102840763 (10 bytes) 20:30:44.387 SERIAL » [ACK] (0x06) 20:30:44.387 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 20:30:44.389 CNTRLR « [Node 017] received wakeup notification 20:30:44.390 CNTRLR [Node 017] The node is now awake. 20:30:44.426 SERIAL « 0x010700132d00009650 (9 bytes) 20:30:44.426 SERIAL » [ACK] (0x06) 20:30:44.427 DRIVER « [REQ] [SendData] callback id: 45 transmit status: OK 20:30:44.516 SERIAL « 0x0110000400160a9880c1cb1c6a8516efe10e (18 bytes) 20:30:44.517 SERIAL » [ACK] (0x06) 20:30:44.520 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xc1cb1c6a8516efe1 20:30:44.525 SERIAL » 0x011d0013161698814aa7214f5526d26730490ec1d349e56de6cbfbe2252b33 (31 bytes) 20:30:44.525 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 43 └─[SecurityCCCommandEncapsulation] │ nonce id: 193 └─[SecurityCCCommandsSupportedGet] 20:30:44.527 SERIAL « [ACK] (0x06) 20:30:44.531 SERIAL « 0x0104011301e8 (6 bytes) 20:30:44.532 SERIAL » [ACK] (0x06) 20:30:44.533 DRIVER « [RES] [SendData] was sent: true 20:30:44.651 SERIAL « 0x010700132b00000dcd (9 bytes) 20:30:44.652 SERIAL » [ACK] (0x06) 20:30:44.652 DRIVER « [REQ] [SendData] callback id: 43 transmit status: OK 20:30:46.261 SERIAL » 0x0109001317029840252e23 (11 bytes) 20:30:46.261 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 46 └─[SecurityCCNonceGet] 20:30:46.262 CNTRLR [Node 022] The node is not included securely. Continuing interview non-securel y. 20:30:46.263 CNTRLR [Node 022] ManufacturerSpecificCC: doing a complete interview... 20:30:46.263 CNTRLR » [Node 022] querying manufacturer information... 20:30:46.265 SERIAL « [ACK] (0x06) 20:30:46.267 SERIAL « 0x0104011301e8 (6 bytes) 20:30:46.267 SERIAL » [ACK] (0x06) 20:30:46.267 DRIVER « [RES] [SendData] was sent: true 20:30:47.595 SERIAL « 0x010c0004001a06310504220b1ae8 (14 bytes) 20:30:47.597 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:30:47.597 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 452.7 => 284.2 [Endpoint 0] 20:30:47.598 SERIAL » [ACK] (0x06) 20:30:47.599 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 284.2 20:30:47.606 SERIAL « 0x0110000400170a98805ba0912f1fb591aa3a (18 bytes) 20:30:47.606 SERIAL » [ACK] (0x06) 20:30:47.607 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x5ba0912f1fb591aa 20:30:48.780 SERIAL « 0x010c0004001a06310504220b1ae8 (14 bytes) 20:30:48.781 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:30:48.782 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 284.2 => 284.2 [Endpoint 0] 20:30:48.783 SERIAL » [ACK] (0x06) 20:30:48.784 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 284.2 20:30:53.488 SERIAL « 0x0114000400050e320221440000019d00640000019dd5 (22 bytes) 20:30:53.489 CNTRLR [Node 005] [Meter] value[65537]: metadata updated [Endpoint 0] 20:30:53.490 CNTRLR [Node 005] [+] [Meter] value[65537]: 4.13 [Endpoint 0] 20:30:53.491 CNTRLR [Node 005] [+] [Meter] deltaTime[65537]: 0 [Endpoint 0] 20:30:53.492 SERIAL » [ACK] (0x06) 20:30:53.494 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 4.13 time delta: 0 seconds 20:30:53.742 SERIAL « 0x010c0004001a063105042207d12f (14 bytes) 20:30:53.743 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:30:53.744 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 284.2 => 200.1 [Endpoint 0] 20:30:53.745 SERIAL » [ACK] (0x06) 20:30:53.746 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 200.1 20:30:53.835 SERIAL « 0x010c0004001a063105042207d12f (14 bytes) 20:30:53.836 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:30:53.837 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 200.1 => 200.1 [Endpoint 0] 20:30:53.838 SERIAL » [ACK] (0x06) 20:30:53.839 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 200.1 20:30:54.012 SERIAL « 0x0114000400050e320221440000019d00640000019dd5 (22 bytes) 20:30:54.013 CNTRLR [Node 005] [~] [Meter] value[65537]: 4.13 => 4.13 [Endpoint 0] 20:30:54.014 CNTRLR [Node 005] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 20:30:54.015 SERIAL » [ACK] (0x06) 20:30:54.016 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 4.13 time delta: 0 seconds 20:30:54.392 DRIVER The awake timeout for node 17 has elapsed. Assuming it is asleep. 20:30:54.392 CNTRLR [Node 017] The node is now asleep. 20:30:56.837 SERIAL « 0x010c0004001a06310504220acd3e (14 bytes) 20:30:56.838 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:30:56.839 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 200.1 => 276.5 [Endpoint 0] 20:30:56.840 SERIAL » [ACK] (0x06) 20:30:56.841 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 276.5 20:30:59.490 SERIAL « 0x010700132e00052aea (9 bytes) 20:30:59.490 SERIAL » [ACK] (0x06) 20:30:59.491 DRIVER « [REQ] [SendData] callback id: 46 transmit status: OK 20:30:59.558 SERIAL « 0x0110000410170a9880e649fc9102f5f13a00 (18 bytes) 20:30:59.559 SERIAL » [ACK] (0x06) 20:30:59.559 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xe649fc9102f5f13a 20:30:59.564 SERIAL » 0x011d00131716988169be1dd0b250bcc17f6bede6618f317f6e8546aa252fde (31 bytes) 20:30:59.564 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 47 └─[SecurityCCCommandEncapsulation] │ nonce id: 230 └─[SecurityCCCommandsSupportedGet] 20:30:59.566 SERIAL « [ACK] (0x06) 20:30:59.568 SERIAL « 0x0104011300e9 (6 bytes) 20:30:59.568 SERIAL » [ACK] (0x06) 20:30:59.569 DRIVER « [RES] [SendData] was sent: false 20:30:59.573 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 20:30:59.674 SERIAL » 0x011d00131716988169be1dd0b250bcc17f6bede6618f317f6e8546aa252fde (31 bytes) 20:30:59.675 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 47 └─[SecurityCCCommandEncapsulation] │ nonce id: 230 └─[SecurityCCCommandsSupportedGet] 20:30:59.677 SERIAL « [ACK] (0x06) 20:30:59.682 SERIAL « 0x0104011301e8 (6 bytes) 20:30:59.683 SERIAL » [ACK] (0x06) 20:30:59.683 DRIVER « [RES] [SendData] was sent: true 20:30:59.737 SERIAL « 0x0110000410170a9880e649fc9102f5f13a00 (18 bytes) 20:30:59.738 SERIAL » [ACK] (0x06) 20:30:59.739 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xe649fc9102f5f13a 20:31:00.160 SERIAL « 0x0110000410170a9880e649fc9102f5f13a00 (18 bytes) 20:31:00.161 SERIAL » [ACK] (0x06) 20:31:00.162 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xe649fc9102f5f13a 20:31:01.370 SERIAL « 0x010c0004001a06310504220db743 (14 bytes) 20:31:01.371 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:01.372 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 276.5 => 351.1 [Endpoint 0] 20:31:01.372 SERIAL » [ACK] (0x06) 20:31:01.373 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 351.1 20:31:02.541 SERIAL « 0x010c0004001a06310504220db743 (14 bytes) 20:31:02.542 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:02.543 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 351.1 => 351.1 [Endpoint 0] 20:31:02.543 SERIAL » [ACK] (0x06) 20:31:02.544 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 351.1 20:31:03.712 SERIAL « 0x010c0004001a06310504220db743 (14 bytes) 20:31:03.713 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:03.714 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 351.1 => 351.1 [Endpoint 0] 20:31:03.714 SERIAL » [ACK] (0x06) 20:31:03.715 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 351.1 20:31:03.879 SERIAL « 0x010c0004001a06310504220db743 (14 bytes) 20:31:03.880 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:03.881 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 351.1 => 351.1 [Endpoint 0] 20:31:03.881 SERIAL » [ACK] (0x06) 20:31:03.882 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 351.1 20:31:03.986 SERIAL « 0x010700132f0001af6a (9 bytes) 20:31:03.986 SERIAL » [ACK] (0x06) 20:31:03.987 DRIVER « [REQ] [SendData] callback id: 47 transmit status: OK 20:31:04.332 SERIAL « 0x010c0004001a06310504220aa655 (14 bytes) 20:31:04.333 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:04.334 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 351.1 => 272.6 [Endpoint 0] 20:31:04.335 SERIAL » [ACK] (0x06) 20:31:04.336 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 272.6 20:31:05.592 CNTRLR [Node 023] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 20:31:06.098 SERIAL » 0x010900131702984025303d (11 bytes) 20:31:06.099 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 48 └─[SecurityCCNonceGet] 20:31:06.100 SERIAL « [ACK] (0x06) 20:31:06.105 SERIAL « 0x0104011301e8 (6 bytes) 20:31:06.105 SERIAL » [ACK] (0x06) 20:31:06.108 DRIVER « [RES] [SendData] was sent: true 20:31:07.523 SERIAL « 0x010700133000008e55 (9 bytes) 20:31:07.524 SERIAL » [ACK] (0x06) 20:31:07.524 DRIVER « [REQ] [SendData] callback id: 48 transmit status: OK 20:31:07.609 SERIAL « 0x0110000400170a988047dabba12dd8088a1e (18 bytes) 20:31:07.610 SERIAL » [ACK] (0x06) 20:31:07.611 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x47dabba12dd8088a 20:31:07.617 SERIAL » 0x011d001317169881ae44e21e7f433dec73c115475668ee9a22f1c7be252f18 (31 bytes) 20:31:07.617 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 47 └─[SecurityCCCommandEncapsulation] │ nonce id: 71 └─[SecurityCCCommandsSupportedGet] 20:31:07.619 SERIAL « [ACK] (0x06) 20:31:07.624 SERIAL « 0x0104011301e8 (6 bytes) 20:31:07.625 SERIAL » [ACK] (0x06) 20:31:07.625 DRIVER « [RES] [SendData] was sent: true 20:31:07.741 SERIAL « 0x010700132f00000cc8 (9 bytes) 20:31:07.742 SERIAL » [ACK] (0x06) 20:31:07.742 DRIVER « [REQ] [SendData] callback id: 47 transmit status: OK 20:31:09.346 CNTRLR [Node 023] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 20:31:09.855 SERIAL » 0x010900131702984025313c (11 bytes) 20:31:09.856 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 49 └─[SecurityCCNonceGet] 20:31:09.857 SERIAL « [ACK] (0x06) 20:31:09.861 SERIAL « 0x0104011301e8 (6 bytes) 20:31:09.862 SERIAL » [ACK] (0x06) 20:31:09.862 DRIVER « [RES] [SendData] was sent: true 20:31:11.262 SERIAL « 0x010700133100008d57 (9 bytes) 20:31:11.263 SERIAL » [ACK] (0x06) 20:31:11.263 DRIVER « [REQ] [SendData] callback id: 49 transmit status: OK 20:31:11.344 SERIAL « 0x0110000400170a9880530a2a5d36b9aebf5e (18 bytes) 20:31:11.344 SERIAL » [ACK] (0x06) 20:31:11.345 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x530a2a5d36b9aebf 20:31:11.348 SERIAL » 0x011d00131716988163de2f8751998a219c1db553e84f4ed5222ba89e252ff1 (31 bytes) 20:31:11.349 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 47 └─[SecurityCCCommandEncapsulation] │ nonce id: 83 └─[SecurityCCCommandsSupportedGet] 20:31:11.351 SERIAL « [ACK] (0x06) 20:31:11.356 SERIAL « 0x0104011301e8 (6 bytes) 20:31:11.356 SERIAL » [ACK] (0x06) 20:31:11.356 DRIVER « [RES] [SendData] was sent: true 20:31:11.480 SERIAL « 0x010700132f00000cc8 (9 bytes) 20:31:11.480 SERIAL » [ACK] (0x06) 20:31:11.481 DRIVER « [REQ] [SendData] callback id: 47 transmit status: OK 20:31:13.089 SERIAL » 0x0109001318029840253230 (11 bytes) 20:31:13.089 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 50 └─[SecurityCCNonceGet] 20:31:13.089 CNTRLR [Node 023] The node is not included securely. Continuing interview non-securel y. 20:31:13.090 CNTRLR [Node 023] ManufacturerSpecificCC: doing a complete interview... 20:31:13.092 CNTRLR » [Node 023] querying manufacturer information... 20:31:13.093 SERIAL « [ACK] (0x06) 20:31:13.094 SERIAL « 0x0104011301e8 (6 bytes) 20:31:13.094 SERIAL » [ACK] (0x06) 20:31:13.095 DRIVER « [RES] [SendData] was sent: true 20:31:14.496 SERIAL « 0x010700133200008c55 (9 bytes) 20:31:14.496 SERIAL » [ACK] (0x06) 20:31:14.497 DRIVER « [REQ] [SendData] callback id: 50 transmit status: OK 20:31:14.582 SERIAL « 0x0110000400180a988098fde543bed540f9f0 (18 bytes) 20:31:14.583 SERIAL » [ACK] (0x06) 20:31:14.584 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x98fde543bed540f9 20:31:14.587 SERIAL » 0x011d00131816988131935a24c6e30609ad6bb798d7da1756ba96aa07253322 (31 bytes) 20:31:14.587 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 51 └─[SecurityCCCommandEncapsulation] │ nonce id: 152 └─[SecurityCCCommandsSupportedGet] 20:31:14.589 SERIAL « 0x0109000400200380032f7d (11 bytes) 20:31:14.589 CNTRLR [Node 032] [+] [Battery] level: 47 [Endpoint 0] 20:31:14.590 CNTRLR [Node 032] [+] [Battery] isLow: false [Endpoint 0] 20:31:14.590 SERIAL » [ACK] (0x06) 20:31:14.590 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 47 is low: false 20:31:14.591 SERIAL « [CAN] (0x18) 20:31:14.593 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 20:31:14.637 SERIAL « 0x010c000400200631050142072c8d (14 bytes) 20:31:14.638 CNTRLR [Node 032] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 20:31:14.639 CNTRLR [Node 032] [+] [Multilevel Sensor] Air temperature: 18.36 [Endpoint 0] 20:31:14.640 SERIAL » [ACK] (0x06) 20:31:14.641 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.36 20:31:14.694 SERIAL » 0x011d00131816988131935a24c6e30609ad6bb798d7da1756ba96aa07253322 (31 bytes) 20:31:14.694 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 51 └─[SecurityCCCommandEncapsulation] │ nonce id: 152 └─[SecurityCCCommandsSupportedGet] 20:31:14.697 SERIAL « [ACK] (0x06) 20:31:14.701 SERIAL « 0x0104011301e8 (6 bytes) 20:31:14.702 SERIAL » [ACK] (0x06) 20:31:14.703 DRIVER « [RES] [SendData] was sent: true 20:31:14.763 SERIAL « 0x0107001333000007df (9 bytes) 20:31:14.763 SERIAL » [ACK] (0x06) 20:31:14.764 DRIVER « [REQ] [SendData] callback id: 51 transmit status: OK 20:31:14.800 SERIAL « 0x010c000400200631050142072c8d (14 bytes) 20:31:14.801 CNTRLR [Node 032] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 20:31:14.802 CNTRLR [Node 032] [~] [Multilevel Sensor] Air temperature: 18.36 => 18.3 [Endpoint 0] 6 20:31:14.802 SERIAL » [ACK] (0x06) 20:31:14.804 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.36 20:31:14.825 SERIAL « 0x01080004002002840752 (10 bytes) 20:31:14.826 SERIAL » [ACK] (0x06) 20:31:14.827 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 20:31:14.837 CNTRLR « [Node 032] received wakeup notification 20:31:14.837 CNTRLR [Node 032] The node is now awake. 20:31:16.370 CNTRLR [Node 024] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 20:31:16.878 SERIAL » 0x0109001318029840253436 (11 bytes) 20:31:16.878 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 52 └─[SecurityCCNonceGet] 20:31:16.880 SERIAL « [ACK] (0x06) 20:31:16.884 SERIAL « 0x0104011301e8 (6 bytes) 20:31:16.884 SERIAL » [ACK] (0x06) 20:31:16.885 DRIVER « [RES] [SendData] was sent: true 20:31:18.232 SERIAL « 0x010700133400008758 (9 bytes) 20:31:18.232 SERIAL » [ACK] (0x06) 20:31:18.233 DRIVER « [REQ] [SendData] callback id: 52 transmit status: OK 20:31:18.315 SERIAL « 0x0110000400180a9880a2ab4dfa25cabafaf0 (18 bytes) 20:31:18.316 SERIAL » [ACK] (0x06) 20:31:18.317 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xa2ab4dfa25cabafa 20:31:18.323 SERIAL » 0x011d00131816988184e787904884980a4b007fa29dc5ffaf29515ffe25339d (31 bytes) 20:31:18.323 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 51 └─[SecurityCCCommandEncapsulation] │ nonce id: 162 └─[SecurityCCCommandsSupportedGet] 20:31:18.325 SERIAL « [ACK] (0x06) 20:31:18.330 SERIAL « 0x0104011301e8 (6 bytes) 20:31:18.330 SERIAL » [ACK] (0x06) 20:31:18.331 DRIVER « [RES] [SendData] was sent: true 20:31:18.450 SERIAL « 0x010700133300000dd5 (9 bytes) 20:31:18.451 SERIAL » [ACK] (0x06) 20:31:18.452 DRIVER « [REQ] [SendData] callback id: 51 transmit status: OK 20:31:19.962 SERIAL « 0x010c0004001a063105042212907b (14 bytes) 20:31:19.963 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:19.964 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 272.6 => 475.2 [Endpoint 0] 20:31:19.965 SERIAL » [ACK] (0x06) 20:31:19.966 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 475.2 20:31:20.056 CNTRLR [Node 024] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 20:31:20.562 SERIAL » 0x0109001318029840253537 (11 bytes) 20:31:20.563 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 53 └─[SecurityCCNonceGet] 20:31:20.564 SERIAL « [ACK] (0x06) 20:31:20.568 SERIAL « 0x0104011301e8 (6 bytes) 20:31:20.568 SERIAL » [ACK] (0x06) 20:31:20.569 DRIVER « [RES] [SendData] was sent: true 20:31:24.409 SERIAL « 0x01070013350001805f (9 bytes) 20:31:24.410 SERIAL » [ACK] (0x06) 20:31:24.410 DRIVER « [REQ] [SendData] callback id: 53 transmit status: OK 20:31:24.550 SERIAL « 0x010c0004001a06310504220853a2 (14 bytes) 20:31:24.551 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:24.552 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 475.2 => 213.1 [Endpoint 0] 20:31:24.552 SERIAL » [ACK] (0x06) 20:31:24.554 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 213.1 20:31:24.660 SERIAL « 0x010c0004001a06310504220a3fcc (14 bytes) 20:31:24.661 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:24.662 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 213.1 => 262.3 [Endpoint 0] 20:31:24.662 SERIAL » [ACK] (0x06) 20:31:24.663 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 262.3 20:31:24.839 DRIVER The awake timeout for node 32 has elapsed. Assuming it is asleep. 20:31:24.840 CNTRLR [Node 032] The node is now asleep. 20:31:25.023 SERIAL « 0x0110000410180a988078578e0dcfd33f5729 (18 bytes) 20:31:25.024 SERIAL » [ACK] (0x06) 20:31:25.024 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x78578e0dcfd33f57 20:31:25.027 SERIAL » 0x011d0013181698813a13deb9c245c4cde3c32f78eb4d35d3056e3ec6253394 (31 bytes) 20:31:25.027 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 51 └─[SecurityCCCommandEncapsulation] │ nonce id: 120 └─[SecurityCCCommandsSupportedGet] 20:31:25.029 SERIAL « [ACK] (0x06) 20:31:25.034 SERIAL « 0x0104011301e8 (6 bytes) 20:31:25.035 SERIAL » [ACK] (0x06) 20:31:25.035 DRIVER « [RES] [SendData] was sent: true 20:31:25.039 SERIAL « 0x0110000410180a988078578e0dcfd33f5729 (18 bytes) 20:31:25.039 SERIAL » [ACK] (0x06) 20:31:25.039 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x78578e0dcfd33f57 20:31:26.241 SERIAL « 0x0110000410180a988078578e0dcfd33f5729 (18 bytes) 20:31:26.241 SERIAL » [ACK] (0x06) 20:31:26.242 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x78578e0dcfd33f57 20:31:26.264 SERIAL « 0x010700133300007ba3 (9 bytes) 20:31:26.265 SERIAL » [ACK] (0x06) 20:31:26.265 DRIVER « [REQ] [SendData] callback id: 51 transmit status: OK 20:31:27.874 SERIAL » 0x010900131a029840253636 (11 bytes) 20:31:27.875 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 54 └─[SecurityCCNonceGet] 20:31:27.876 CNTRLR [Node 024] The node is not included securely. Continuing interview non-securel y. 20:31:27.880 CNTRLR [Node 024] ManufacturerSpecificCC: doing a complete interview... 20:31:27.880 CNTRLR » [Node 024] querying manufacturer information... 20:31:27.884 SERIAL « [ACK] (0x06) 20:31:27.885 SERIAL « 0x0104011301e8 (6 bytes) 20:31:27.885 SERIAL » [ACK] (0x06) 20:31:27.886 DRIVER « [RES] [SendData] was sent: true 20:31:28.018 SERIAL « 0x010700133600000ed3 (9 bytes) 20:31:28.019 SERIAL » [ACK] (0x06) 20:31:28.019 DRIVER « [REQ] [SendData] callback id: 54 transmit status: OK 20:31:29.623 CNTRLR [Node 026] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 20:31:30.131 SERIAL » 0x010900131a029840253737 (11 bytes) 20:31:30.131 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 55 └─[SecurityCCNonceGet] 20:31:30.132 SERIAL « [ACK] (0x06) 20:31:30.136 SERIAL « 0x0104011301e8 (6 bytes) 20:31:30.137 SERIAL » [ACK] (0x06) 20:31:30.137 DRIVER « [RES] [SendData] was sent: true 20:31:30.286 SERIAL « 0x010700133700000fd3 (9 bytes) 20:31:30.286 SERIAL » [ACK] (0x06) 20:31:30.287 DRIVER « [REQ] [SendData] callback id: 55 transmit status: OK 20:31:30.963 SERIAL « 0x010c0004001a063105042211c028 (14 bytes) 20:31:30.966 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:30.967 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 262.3 => 454.4 [Endpoint 0] 20:31:30.967 SERIAL » [ACK] (0x06) 20:31:30.970 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 454.4 20:31:31.891 CNTRLR [Node 026] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 20:31:32.397 SERIAL » 0x010900131a029840253838 (11 bytes) 20:31:32.397 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 56 └─[SecurityCCNonceGet] 20:31:32.398 SERIAL « [ACK] (0x06) 20:31:32.402 SERIAL « 0x0104011301e8 (6 bytes) 20:31:32.403 SERIAL » [ACK] (0x06) 20:31:32.403 DRIVER « [RES] [SendData] was sent: true 20:31:32.539 SERIAL « 0x010700133800000edd (9 bytes) 20:31:32.540 SERIAL » [ACK] (0x06) 20:31:32.541 DRIVER « [REQ] [SendData] callback id: 56 transmit status: OK 20:31:32.963 SERIAL « 0x010c0004001a06310504220aaf5c (14 bytes) 20:31:32.964 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:32.965 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 454.4 => 273.5 [Endpoint 0] 20:31:32.966 SERIAL » [ACK] (0x06) 20:31:32.967 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 273.5 20:31:34.150 SERIAL » 0x010900131c02984025393f (11 bytes) 20:31:34.151 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 57 └─[SecurityCCNonceGet] 20:31:34.151 CNTRLR [Node 026] The node is not included securely. Continuing interview non-securel y. 20:31:34.152 CNTRLR [Node 026] ManufacturerSpecificCC: doing a complete interview... 20:31:34.152 CNTRLR » [Node 026] querying manufacturer information... 20:31:34.154 SERIAL « [ACK] (0x06) 20:31:34.156 SERIAL « 0x0104011301e8 (6 bytes) 20:31:34.156 SERIAL » [ACK] (0x06) 20:31:34.157 DRIVER « [RES] [SendData] was sent: true 20:31:34.171 SERIAL « 0x0107001339000002d0 (9 bytes) 20:31:34.171 SERIAL » [ACK] (0x06) 20:31:34.172 DRIVER « [REQ] [SendData] callback id: 57 transmit status: OK 20:31:35.774 CNTRLR [Node 028] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 20:31:36.281 SERIAL » 0x010900131c029840253a3c (11 bytes) 20:31:36.281 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 58 └─[SecurityCCNonceGet] 20:31:36.282 SERIAL « [ACK] (0x06) 20:31:36.286 SERIAL « 0x0104011301e8 (6 bytes) 20:31:36.287 SERIAL » [ACK] (0x06) 20:31:36.287 DRIVER « [RES] [SendData] was sent: true 20:31:36.301 SERIAL « 0x010700133a000002d3 (9 bytes) 20:31:36.302 SERIAL » [ACK] (0x06) 20:31:36.302 DRIVER « [REQ] [SendData] callback id: 58 transmit status: OK 20:31:37.905 CNTRLR [Node 028] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 20:31:38.413 SERIAL » 0x010900131c029840253b3d (11 bytes) 20:31:38.413 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 59 └─[SecurityCCNonceGet] 20:31:38.414 SERIAL « [ACK] (0x06) 20:31:38.418 SERIAL « 0x0104011301e8 (6 bytes) 20:31:38.419 SERIAL » [ACK] (0x06) 20:31:38.419 DRIVER « [RES] [SendData] was sent: true 20:31:38.433 SERIAL « 0x010700133b000002d2 (9 bytes) 20:31:38.434 SERIAL » [ACK] (0x06) 20:31:38.434 DRIVER « [REQ] [SendData] callback id: 59 transmit status: OK 20:31:40.040 SERIAL » 0x010a00130303861325253c4f (12 bytes) 20:31:40.041 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 60 └─[VersionCCCommandClassGet] CC: Binary Switch 20:31:40.041 CNTRLR [Node 028] The node is not included securely. Continuing interview non-securel y. 20:31:40.042 CNTRLR [Node 028] ManufacturerSpecificCC: doing a complete interview... 20:31:40.042 CNTRLR » [Node 028] querying manufacturer information... 20:31:40.043 SERIAL « [ACK] (0x06) 20:31:40.046 SERIAL « 0x0104011301e8 (6 bytes) 20:31:40.046 SERIAL » [ACK] (0x06) 20:31:40.046 DRIVER « [RES] [SendData] was sent: true 20:31:40.065 SERIAL « 0x010700133c000002d5 (9 bytes) 20:31:40.066 SERIAL » [ACK] (0x06) 20:31:40.067 DRIVER « [REQ] [SendData] callback id: 60 transmit status: OK 20:31:40.078 SERIAL « 0x010a00040003048614250140 (12 bytes) 20:31:40.079 SERIAL » [ACK] (0x06) 20:31:40.079 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Binary Switch version: 1 20:31:40.086 SERIAL » 0x010a0013050386135e253d33 (12 bytes) 20:31:40.087 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 61 └─[VersionCCCommandClassGet] CC: Z-Wave Plus Info 20:31:40.087 CNTRLR [Node 003] supports CC Binary Switch (0x25) in version 1 20:31:40.087 CNTRLR [Node 003] skipping query for All Switch (0x27) because max implemented vers ion is 0 20:31:40.088 CNTRLR » [Node 003] querying the CC version for Z-Wave Plus Info (0x5e)... 20:31:40.091 SERIAL « [ACK] (0x06) 20:31:40.092 SERIAL « 0x0104011301e8 (6 bytes) 20:31:40.093 SERIAL » [ACK] (0x06) 20:31:40.093 DRIVER « [RES] [SendData] was sent: true 20:31:40.108 SERIAL « 0x010700133d000002d4 (9 bytes) 20:31:40.108 SERIAL » [ACK] (0x06) 20:31:40.109 DRIVER « [REQ] [SendData] callback id: 61 transmit status: OK 20:31:40.117 SERIAL « 0x010a000400050486145e023e (12 bytes) 20:31:40.118 SERIAL » [ACK] (0x06) 20:31:40.119 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Z-Wave Plus Info version: 2 20:31:40.124 SERIAL » 0x010a0013060386135e253e33 (12 bytes) 20:31:40.125 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 62 └─[VersionCCCommandClassGet] CC: Z-Wave Plus Info 20:31:40.125 CNTRLR [Node 005] supports CC Z-Wave Plus Info (0x5e) in version 2 20:31:40.126 CNTRLR » [Node 005] querying the CC version for Version (0x86)... 20:31:40.129 SERIAL « [ACK] (0x06) 20:31:40.130 SERIAL « 0x0104011301e8 (6 bytes) 20:31:40.131 SERIAL » [ACK] (0x06) 20:31:40.131 DRIVER « [RES] [SendData] was sent: true 20:31:40.145 SERIAL « 0x010700133e000002d7 (9 bytes) 20:31:40.146 SERIAL » [ACK] (0x06) 20:31:40.148 DRIVER « [REQ] [SendData] callback id: 62 transmit status: OK 20:31:40.155 SERIAL « 0x010a000400060486145e023d (12 bytes) 20:31:40.156 SERIAL » [ACK] (0x06) 20:31:40.157 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Z-Wave Plus Info version: 2 20:31:40.160 SERIAL » 0x010a0013020386135e253f36 (12 bytes) 20:31:40.160 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 63 └─[VersionCCCommandClassGet] CC: Z-Wave Plus Info 20:31:40.161 CNTRLR [Node 006] supports CC Z-Wave Plus Info (0x5e) in version 2 20:31:40.161 CNTRLR » [Node 006] querying the CC version for Version (0x86)... 20:31:40.164 SERIAL « [ACK] (0x06) 20:31:40.166 SERIAL « 0x0104011301e8 (6 bytes) 20:31:40.166 SERIAL » [ACK] (0x06) 20:31:40.166 DRIVER « [RES] [SendData] was sent: true 20:31:40.186 SERIAL « 0x010700133f000002d6 (9 bytes) 20:31:40.186 SERIAL » [ACK] (0x06) 20:31:40.188 DRIVER « [REQ] [SendData] callback id: 63 transmit status: OK 20:31:40.213 SERIAL « 0x010a000400020486145e0239 (12 bytes) 20:31:40.214 SERIAL » [ACK] (0x06) 20:31:40.215 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Z-Wave Plus Info version: 2 20:31:40.218 SERIAL » 0x01090013130272042540e7 (11 bytes) 20:31:40.218 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 64 └─[ManufacturerSpecificCCGet] 20:31:40.219 CNTRLR [Node 002] supports CC Z-Wave Plus Info (0x5e) in version 2 20:31:40.219 CNTRLR » [Node 002] querying the CC version for Version (0x86)... 20:31:40.222 SERIAL « [ACK] (0x06) 20:31:40.225 SERIAL « 0x0104011301e8 (6 bytes) 20:31:40.228 SERIAL » [ACK] (0x06) 20:31:40.229 DRIVER « [RES] [SendData] was sent: true 20:31:40.364 SERIAL « 0x010700134000000ea5 (9 bytes) 20:31:40.364 SERIAL » [ACK] (0x06) 20:31:40.365 DRIVER « [REQ] [SendData] callback id: 64 transmit status: OK 20:31:40.501 SERIAL « 0x010e00040013087205010f0602100380 (16 bytes) 20:31:40.503 CNTRLR [Node 019] [+] [Manufacturer Specific] manufacturerId: 271 [Endpoint 0] 20:31:40.503 CNTRLR [Node 019] [+] [Manufacturer Specific] productType: 1538 [Endpoint 0] 20:31:40.504 CNTRLR [Node 019] [+] [Manufacturer Specific] productId: 4099 [Endpoint 0] 20:31:40.504 SERIAL » [ACK] (0x06) 20:31:40.506 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ManufacturerSpecificCCReport] manufacturer id: 0x010f product type: 0x0602 product id: 0x1003 20:31:40.509 SERIAL » 0x0109001312028611254106 (11 bytes) 20:31:40.510 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 65 └─[VersionCCGet] 20:31:40.510 CNTRLR « [Node 019] received response for manufacturer information: manufacturer: Fibargroup (0x010f) product type: 0x0602 product id: 0x1003 20:31:40.511 CNTRLR [Node 019] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 20:31:40.521 SERIAL « [ACK] (0x06) 20:31:40.524 SERIAL « 0x0104011301e8 (6 bytes) 20:31:40.524 SERIAL » [ACK] (0x06) 20:31:40.525 DRIVER « [RES] [SendData] was sent: true 20:31:40.529 CNTRLR [Node 019] VersionCC: doing a complete interview... 20:31:40.529 CNTRLR » [Node 019] querying node versions... 20:31:40.634 SERIAL « 0x010700134100000ca6 (9 bytes) 20:31:40.635 SERIAL » [ACK] (0x06) 20:31:40.636 DRIVER « [REQ] [SendData] callback id: 65 transmit status: OK 20:31:40.645 SERIAL « 0x010f00040012098612030422010e010050 (17 bytes) 20:31:40.646 CNTRLR [Node 018] [+] [Version] libraryType: 3 [Endpoint 0] 20:31:40.647 CNTRLR [Node 018] [+] [Version] protocolVersion: "4.34" [Endpoint 0] 20:31:40.647 CNTRLR [Node 018] [+] [Version] firmwareVersions: 1.14 [Endpoint 0] 20:31:40.648 SERIAL » [ACK] (0x06) 20:31:40.649 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[VersionCCReport] library type: Enhanced Slave protocol version: 4.34 firmware versions: 1.14 20:31:40.658 SERIAL » 0x01090013140272042542e2 (11 bytes) 20:31:40.659 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 66 └─[ManufacturerSpecificCCGet] 20:31:40.659 CNTRLR « [Node 018] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 4.34 firmware versions: 1.14 20:31:40.659 CNTRLR » [Node 018] querying CC versions... 20:31:40.660 CNTRLR » [Node 018] querying the CC version for Binary Switch (0x25)... 20:31:40.665 SERIAL « [ACK] (0x06) 20:31:40.667 SERIAL « 0x0104011301e8 (6 bytes) 20:31:40.667 SERIAL » [ACK] (0x06) 20:31:40.668 DRIVER « [RES] [SendData] was sent: true 20:31:40.704 SERIAL « 0x0107001342000004ad (9 bytes) 20:31:40.705 SERIAL » [ACK] (0x06) 20:31:40.705 DRIVER « [REQ] [SendData] callback id: 66 transmit status: OK 20:31:40.717 SERIAL « 0x010e00040014087205017500010011fa (16 bytes) 20:31:40.718 CNTRLR [Node 020] [+] [Manufacturer Specific] manufacturerId: 373 [Endpoint 0] 20:31:40.719 CNTRLR [Node 020] [+] [Manufacturer Specific] productType: 1 [Endpoint 0] 20:31:40.720 CNTRLR [Node 020] [+] [Manufacturer Specific] productId: 17 [Endpoint 0] 20:31:40.720 SERIAL » [ACK] (0x06) 20:31:40.722 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[ManufacturerSpecificCCReport] manufacturer id: 0x0175 product type: 0x01 product id: 0x11 20:31:40.725 SERIAL » 0x01090013150272042543e2 (11 bytes) 20:31:40.725 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 67 └─[ManufacturerSpecificCCGet] 20:31:40.725 CNTRLR « [Node 020] received response for manufacturer information: manufacturer: Devolo (0x0175) product type: 0x01 product id: 0x11 20:31:40.726 CNTRLR [Node 020] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 20:31:40.734 SERIAL « [ACK] (0x06) 20:31:40.736 SERIAL « 0x0104011301e8 (6 bytes) 20:31:40.737 SERIAL » [ACK] (0x06) 20:31:40.738 DRIVER « [RES] [SendData] was sent: true 20:31:40.739 CNTRLR [Node 020] VersionCC: doing a complete interview... 20:31:40.740 CNTRLR » [Node 020] querying node versions... 20:31:42.079 SERIAL « 0x01070013430000872f (9 bytes) 20:31:42.080 SERIAL » [ACK] (0x06) 20:31:42.081 DRIVER « [REQ] [SendData] callback id: 67 transmit status: OK 20:31:42.165 SERIAL « 0x010e00040015087205014800030001d4 (16 bytes) 20:31:42.166 CNTRLR [Node 021] [+] [Manufacturer Specific] manufacturerId: 328 [Endpoint 0] 20:31:42.167 CNTRLR [Node 021] [+] [Manufacturer Specific] productType: 3 [Endpoint 0] 20:31:42.169 CNTRLR [Node 021] [+] [Manufacturer Specific] productId: 1 [Endpoint 0] 20:31:42.170 SERIAL » [ACK] (0x06) 20:31:42.172 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ManufacturerSpecificCCReport] manufacturer id: 0x0148 product type: 0x03 product id: 0x01 20:31:42.176 SERIAL » 0x01090013160272042544e6 (11 bytes) 20:31:42.177 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 68 └─[ManufacturerSpecificCCGet] 20:31:42.177 CNTRLR « [Node 021] received response for manufacturer information: manufacturer: Eurotronics (0x0148) product type: 0x03 product id: 0x01 20:31:42.178 CNTRLR [Node 021] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 20:31:42.186 SERIAL « [ACK] (0x06) 20:31:42.188 SERIAL « 0x0104011301e8 (6 bytes) 20:31:42.189 SERIAL » [ACK] (0x06) 20:31:42.190 DRIVER « [RES] [SendData] was sent: true 20:31:42.192 CNTRLR [Node 021] VersionCC: doing a complete interview... 20:31:42.192 CNTRLR » [Node 021] querying node versions... 20:31:43.607 SERIAL « 0x010700134400008f20 (9 bytes) 20:31:43.607 SERIAL » [ACK] (0x06) 20:31:43.608 DRIVER « [REQ] [SendData] callback id: 68 transmit status: OK 20:31:43.638 SERIAL « 0x010c0004001a063105042213b359 (14 bytes) 20:31:43.639 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:43.639 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 273.5 => 504.3 [Endpoint 0] 20:31:43.640 SERIAL » [ACK] (0x06) 20:31:43.640 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 504.3 20:31:44.067 SERIAL « 0x010e00040016087205014800030001d7 (16 bytes) 20:31:44.068 CNTRLR [Node 022] [+] [Manufacturer Specific] manufacturerId: 328 [Endpoint 0] 20:31:44.069 CNTRLR [Node 022] [+] [Manufacturer Specific] productType: 3 [Endpoint 0] 20:31:44.069 CNTRLR [Node 022] [+] [Manufacturer Specific] productId: 1 [Endpoint 0] 20:31:44.070 SERIAL » [ACK] (0x06) 20:31:44.071 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ManufacturerSpecificCCReport] manufacturer id: 0x0148 product type: 0x03 product id: 0x01 20:31:44.072 SERIAL » 0x01090013170272042545e6 (11 bytes) 20:31:44.072 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 69 └─[ManufacturerSpecificCCGet] 20:31:44.072 CNTRLR « [Node 022] received response for manufacturer information: manufacturer: Eurotronics (0x0148) product type: 0x03 product id: 0x01 20:31:44.072 CNTRLR [Node 022] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 20:31:44.077 SERIAL « [ACK] (0x06) 20:31:44.077 SERIAL « 0x0104011301e8 (6 bytes) 20:31:44.077 SERIAL » [ACK] (0x06) 20:31:44.078 DRIVER « [RES] [SendData] was sent: true 20:31:44.078 CNTRLR [Node 022] VersionCC: doing a complete interview... 20:31:44.078 CNTRLR » [Node 022] querying node versions... 20:31:45.494 SERIAL « 0x010700134500008e20 (9 bytes) 20:31:45.494 SERIAL » [ACK] (0x06) 20:31:45.495 DRIVER « [REQ] [SendData] callback id: 69 transmit status: OK 20:31:45.578 SERIAL « 0x010e00040017087205014800030001d6 (16 bytes) 20:31:45.579 CNTRLR [Node 023] [+] [Manufacturer Specific] manufacturerId: 328 [Endpoint 0] 20:31:45.579 CNTRLR [Node 023] [+] [Manufacturer Specific] productType: 3 [Endpoint 0] 20:31:45.580 CNTRLR [Node 023] [+] [Manufacturer Specific] productId: 1 [Endpoint 0] 20:31:45.581 SERIAL » [ACK] (0x06) 20:31:45.582 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ManufacturerSpecificCCReport] manufacturer id: 0x0148 product type: 0x03 product id: 0x01 20:31:45.591 SERIAL » 0x01090013180272042546ea (11 bytes) 20:31:45.591 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 70 └─[ManufacturerSpecificCCGet] 20:31:45.592 CNTRLR « [Node 023] received response for manufacturer information: manufacturer: Eurotronics (0x0148) product type: 0x03 product id: 0x01 20:31:45.592 CNTRLR [Node 023] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 20:31:45.596 SERIAL « [ACK] (0x06) 20:31:45.597 SERIAL « 0x0104011301e8 (6 bytes) 20:31:45.597 SERIAL » [ACK] (0x06) 20:31:45.598 DRIVER « [RES] [SendData] was sent: true 20:31:45.599 CNTRLR [Node 023] VersionCC: doing a complete interview... 20:31:45.599 CNTRLR » [Node 023] querying node versions... 20:31:47.035 SERIAL « 0x01070013460000903d (9 bytes) 20:31:47.036 SERIAL » [ACK] (0x06) 20:31:47.037 DRIVER « [REQ] [SendData] callback id: 70 transmit status: OK 20:31:47.074 SERIAL « 0x010c0004001a06310504220a7e8d (14 bytes) 20:31:47.075 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:47.075 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 504.3 => 268.6 [Endpoint 0] 20:31:47.076 SERIAL » [ACK] (0x06) 20:31:47.077 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 268.6 20:31:47.151 SERIAL « 0x010e00040018087205014800030001d9 (16 bytes) 20:31:47.152 CNTRLR [Node 024] [+] [Manufacturer Specific] manufacturerId: 328 [Endpoint 0] 20:31:47.152 CNTRLR [Node 024] [+] [Manufacturer Specific] productType: 3 [Endpoint 0] 20:31:47.153 CNTRLR [Node 024] [+] [Manufacturer Specific] productId: 1 [Endpoint 0] 20:31:47.153 SERIAL » [ACK] (0x06) 20:31:47.155 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ManufacturerSpecificCCReport] manufacturer id: 0x0148 product type: 0x03 product id: 0x01 20:31:47.158 SERIAL » 0x010900131a0272042547e9 (11 bytes) 20:31:47.158 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 71 └─[ManufacturerSpecificCCGet] 20:31:47.159 CNTRLR « [Node 024] received response for manufacturer information: manufacturer: Eurotronics (0x0148) product type: 0x03 product id: 0x01 20:31:47.159 CNTRLR [Node 024] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 20:31:47.175 SERIAL « [ACK] (0x06) 20:31:47.178 SERIAL « 0x0104011301e8 (6 bytes) 20:31:47.179 SERIAL » [ACK] (0x06) 20:31:47.180 DRIVER « [RES] [SendData] was sent: true 20:31:47.182 CNTRLR [Node 024] VersionCC: doing a complete interview... 20:31:47.182 CNTRLR » [Node 024] querying node versions... 20:31:47.409 SERIAL « 0x0107001347000018b4 (9 bytes) 20:31:47.409 SERIAL » [ACK] (0x06) 20:31:47.410 DRIVER « [REQ] [SendData] callback id: 71 transmit status: OK 20:31:47.542 SERIAL « 0x010e0004001a087205010f0602100389 (16 bytes) 20:31:47.543 CNTRLR [Node 026] [+] [Manufacturer Specific] manufacturerId: 271 [Endpoint 0] 20:31:47.544 CNTRLR [Node 026] [+] [Manufacturer Specific] productType: 1538 [Endpoint 0] 20:31:47.544 CNTRLR [Node 026] [+] [Manufacturer Specific] productId: 4099 [Endpoint 0] 20:31:47.545 SERIAL » [ACK] (0x06) 20:31:47.545 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ManufacturerSpecificCCReport] manufacturer id: 0x010f product type: 0x0602 product id: 0x1003 20:31:47.547 SERIAL » 0x010900131c0272042548e0 (11 bytes) 20:31:47.548 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 72 └─[ManufacturerSpecificCCGet] 20:31:47.548 CNTRLR « [Node 026] received response for manufacturer information: manufacturer: Fibargroup (0x010f) product type: 0x0602 product id: 0x1003 20:31:47.548 CNTRLR [Node 026] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 20:31:47.552 SERIAL « [ACK] (0x06) 20:31:47.553 SERIAL « 0x0104011301e8 (6 bytes) 20:31:47.553 SERIAL » [ACK] (0x06) 20:31:47.554 DRIVER « [RES] [SendData] was sent: true 20:31:47.555 CNTRLR [Node 026] VersionCC: doing a complete interview... 20:31:47.555 CNTRLR » [Node 026] querying node versions... 20:31:47.674 SERIAL « 0x010700134800000dae (9 bytes) 20:31:47.675 SERIAL » [ACK] (0x06) 20:31:47.675 DRIVER « [REQ] [SendData] callback id: 72 transmit status: OK 20:31:47.685 SERIAL « 0x010e0004001c087205010f060210038f (16 bytes) 20:31:47.686 CNTRLR [Node 028] [+] [Manufacturer Specific] manufacturerId: 271 [Endpoint 0] 20:31:47.686 CNTRLR [Node 028] [+] [Manufacturer Specific] productType: 1538 [Endpoint 0] 20:31:47.687 CNTRLR [Node 028] [+] [Manufacturer Specific] productId: 4099 [Endpoint 0] 20:31:47.687 SERIAL » [ACK] (0x06) 20:31:47.689 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ManufacturerSpecificCCReport] manufacturer id: 0x010f product type: 0x0602 product id: 0x1003 20:31:47.696 SERIAL » 0x010a0013030386135e254941 (12 bytes) 20:31:47.697 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 73 └─[VersionCCCommandClassGet] CC: Z-Wave Plus Info 20:31:47.697 CNTRLR « [Node 028] received response for manufacturer information: manufacturer: Fibargroup (0x010f) product type: 0x0602 product id: 0x1003 20:31:47.697 CNTRLR [Node 028] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 20:31:47.698 CNTRLR [Node 028] VersionCC: doing a complete interview... 20:31:47.698 CNTRLR » [Node 028] querying node versions... 20:31:47.702 SERIAL « [ACK] (0x06) 20:31:47.703 SERIAL « 0x0104011301e8 (6 bytes) 20:31:47.704 SERIAL » [ACK] (0x06) 20:31:47.705 DRIVER « [RES] [SendData] was sent: true 20:31:47.722 SERIAL « 0x0107001349000003a1 (9 bytes) 20:31:47.722 SERIAL » [ACK] (0x06) 20:31:47.723 DRIVER « [REQ] [SendData] callback id: 73 transmit status: OK 20:31:47.734 SERIAL « 0x010a000400030486145e0238 (12 bytes) 20:31:47.735 SERIAL » [ACK] (0x06) 20:31:47.736 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Z-Wave Plus Info version: 2 20:31:47.740 SERIAL » 0x010a00130503861386254a9c (12 bytes) 20:31:47.740 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 74 └─[VersionCCCommandClassGet] CC: Version 20:31:47.741 CNTRLR [Node 003] supports CC Z-Wave Plus Info (0x5e) in version 2 20:31:47.741 CNTRLR [Node 003] skipping query for Application Status (0x22) because max implemen ted version is 0 20:31:47.741 CNTRLR » [Node 003] querying the CC version for Association (0x85)... 20:31:47.744 SERIAL « [ACK] (0x06) 20:31:47.746 SERIAL « 0x0104011301e8 (6 bytes) 20:31:47.746 SERIAL » [ACK] (0x06) 20:31:47.747 DRIVER « [RES] [SendData] was sent: true 20:31:47.761 SERIAL « 0x010700134a000002a3 (9 bytes) 20:31:47.761 SERIAL » [ACK] (0x06) 20:31:47.762 DRIVER « [REQ] [SendData] callback id: 74 transmit status: OK 20:31:47.771 SERIAL « 0x010a000400050486148602e6 (12 bytes) 20:31:47.771 SERIAL » [ACK] (0x06) 20:31:47.772 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 2 20:31:47.778 SERIAL » 0x010a00130603861386254b9e (12 bytes) 20:31:47.778 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 75 └─[VersionCCCommandClassGet] CC: Version 20:31:47.779 CNTRLR [Node 005] supports CC Version (0x86) in version 2 20:31:47.779 CNTRLR » [Node 005] querying the CC version for Manufacturer Specific (0x72)... 20:31:47.781 SERIAL « [ACK] (0x06) 20:31:47.783 SERIAL « 0x0104011301e8 (6 bytes) 20:31:47.784 SERIAL » [ACK] (0x06) 20:31:47.784 DRIVER « [RES] [SendData] was sent: true 20:31:47.799 SERIAL « 0x010700134b000001a1 (9 bytes) 20:31:47.799 SERIAL » [ACK] (0x06) 20:31:47.799 DRIVER « [REQ] [SendData] callback id: 75 transmit status: OK 20:31:47.808 SERIAL « 0x010a000400060486148602e5 (12 bytes) 20:31:47.809 SERIAL » [ACK] (0x06) 20:31:47.809 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 2 20:31:47.811 SERIAL » 0x010a00130203861386254c9d (12 bytes) 20:31:47.812 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 76 └─[VersionCCCommandClassGet] CC: Version 20:31:47.812 CNTRLR [Node 006] supports CC Version (0x86) in version 2 20:31:47.812 CNTRLR » [Node 006] querying the CC version for Manufacturer Specific (0x72)... 20:31:47.813 SERIAL « [ACK] (0x06) 20:31:47.817 SERIAL « 0x0104011301e8 (6 bytes) 20:31:47.817 SERIAL » [ACK] (0x06) 20:31:47.817 DRIVER « [RES] [SendData] was sent: true 20:31:47.837 SERIAL « 0x010700134c000002a5 (9 bytes) 20:31:47.837 SERIAL » [ACK] (0x06) 20:31:47.837 DRIVER « [REQ] [SendData] callback id: 76 transmit status: OK 20:31:47.864 SERIAL « 0x010a000400020486148602e1 (12 bytes) 20:31:47.865 SERIAL » [ACK] (0x06) 20:31:47.866 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 2 20:31:47.868 SERIAL » 0x0109001313028611254d0b (11 bytes) 20:31:47.868 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 77 └─[VersionCCGet] 20:31:47.869 CNTRLR [Node 002] supports CC Version (0x86) in version 2 20:31:47.869 CNTRLR » [Node 002] querying the CC version for Manufacturer Specific (0x72)... 20:31:47.871 SERIAL « [ACK] (0x06) 20:31:47.874 SERIAL « 0x0104011301e8 (6 bytes) 20:31:47.874 SERIAL » [ACK] (0x06) 20:31:47.874 DRIVER « [RES] [SendData] was sent: true 20:31:48.014 SERIAL « 0x010700134d00000ea8 (9 bytes) 20:31:48.014 SERIAL » [ACK] (0x06) 20:31:48.015 DRIVER « [REQ] [SendData] callback id: 77 transmit status: OK 20:31:48.156 SERIAL « 0x0111000400130b86120304180302020103027a (19 bytes) 20:31:48.157 CNTRLR [Node 019] [+] [Version] libraryType: 3 [Endpoint 0] 20:31:48.157 CNTRLR [Node 019] [+] [Version] protocolVersion: "4.24" [Endpoint 0] 20:31:48.158 CNTRLR [Node 019] [+] [Version] firmwareVersions: 3.2 [Endpoint 0] 20:31:48.158 SERIAL » [ACK] (0x06) 20:31:48.159 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[VersionCCReport] library type: Enhanced Slave protocol version: 4.24 firmware versions: 3.2 20:31:48.160 SERIAL » 0x010a00131203861325254e2c (12 bytes) 20:31:48.161 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 78 └─[VersionCCCommandClassGet] CC: Binary Switch 20:31:48.161 CNTRLR « [Node 019] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 4.24 firmware versions: 3.2 20:31:48.161 CNTRLR » [Node 019] querying CC versions... 20:31:48.161 CNTRLR » [Node 019] querying the CC version for Binary Switch (0x25)... 20:31:48.163 SERIAL « [ACK] (0x06) 20:31:48.166 SERIAL « 0x0104011301e8 (6 bytes) 20:31:48.166 SERIAL » [ACK] (0x06) 20:31:48.166 DRIVER « [RES] [SendData] was sent: true 20:31:48.284 SERIAL « 0x010700134e00000ca9 (9 bytes) 20:31:48.285 SERIAL » [ACK] (0x06) 20:31:48.285 DRIVER « [REQ] [SendData] callback id: 78 transmit status: OK 20:31:48.295 SERIAL « 0x010a00040012048614250151 (12 bytes) 20:31:48.295 SERIAL » [ACK] (0x06) 20:31:48.296 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Binary Switch version: 1 20:31:48.300 SERIAL » 0x0109001314028611254f0e (11 bytes) 20:31:48.300 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 79 └─[VersionCCGet] 20:31:48.301 CNTRLR [Node 018] supports CC Binary Switch (0x25) in version 1 20:31:48.301 CNTRLR [Node 018] skipping query for All Switch (0x27) because max implemented vers ion is 0 20:31:48.301 CNTRLR » [Node 018] querying the CC version for Z-Wave Plus Info (0x5e)... 20:31:48.303 SERIAL « [ACK] (0x06) 20:31:48.306 SERIAL « 0x0104011301e8 (6 bytes) 20:31:48.306 SERIAL » [ACK] (0x06) 20:31:48.306 DRIVER « [RES] [SendData] was sent: true 20:31:48.325 SERIAL « 0x010700134f000002a6 (9 bytes) 20:31:48.325 SERIAL » [ACK] (0x06) 20:31:48.326 DRIVER « [REQ] [SendData] callback id: 79 transmit status: OK 20:31:48.355 SERIAL « 0x0111000400140b8612030353010a0100010a33 (19 bytes) 20:31:48.356 CNTRLR [Node 020] [+] [Version] libraryType: 3 [Endpoint 0] 20:31:48.356 CNTRLR [Node 020] [+] [Version] protocolVersion: "3.83" [Endpoint 0] 20:31:48.357 CNTRLR [Node 020] [+] [Version] firmwareVersions: 1.10 [Endpoint 0] 20:31:48.357 SERIAL » [ACK] (0x06) 20:31:48.359 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[VersionCCReport] library type: Enhanced Slave protocol version: 3.83 firmware versions: 1.10 20:31:48.370 SERIAL » 0x0109001315028611255010 (11 bytes) 20:31:48.370 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 80 └─[VersionCCGet] 20:31:48.370 CNTRLR « [Node 020] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 3.83 firmware versions: 1.10 20:31:48.371 CNTRLR » [Node 020] querying CC versions... 20:31:48.371 CNTRLR » [Node 020] querying the CC version for Binary Switch (0x25)... 20:31:48.377 SERIAL « [ACK] (0x06) 20:31:48.379 SERIAL « 0x0104011301e8 (6 bytes) 20:31:48.379 SERIAL » [ACK] (0x06) 20:31:48.381 DRIVER « [RES] [SendData] was sent: true 20:31:50.891 SERIAL « 0x010c0004001c0631050422021be6 (14 bytes) 20:31:50.892 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:50.893 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 67.2 => 53.9 [Endpoint 0] 20:31:50.893 SERIAL » [ACK] (0x06) 20:31:50.895 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 53.9 20:31:50.918 SERIAL « 0x010c0004001a063105042206f00f (14 bytes) 20:31:50.919 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:50.920 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 268.6 => 177.6 [Endpoint 0] 20:31:50.921 SERIAL » [ACK] (0x06) 20:31:50.922 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 177.6 20:31:52.059 SERIAL « 0x010c0004001c0631050422021be6 (14 bytes) 20:31:52.060 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:52.060 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 53.9 => 53.9 [Endpoint 0] 20:31:52.061 SERIAL » [ACK] (0x06) 20:31:52.062 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 53.9 20:31:52.086 SERIAL « 0x010c0004001a063105042206f00f (14 bytes) 20:31:52.086 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:52.087 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 177.6 => 177.6 [Endpoint 0] 20:31:52.087 SERIAL » [ACK] (0x06) 20:31:52.088 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 177.6 20:31:52.143 SERIAL « 0x010c0004001c0631050422021be6 (14 bytes) 20:31:52.144 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:52.145 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 53.9 => 53.9 [Endpoint 0] 20:31:52.145 SERIAL » [ACK] (0x06) 20:31:52.147 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 53.9 20:31:52.166 SERIAL « 0x010c0004001c0631050422028a77 (14 bytes) 20:31:52.167 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:52.168 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 53.9 => 65 [Endpoint 0] 20:31:52.169 SERIAL » [ACK] (0x06) 20:31:52.170 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 65 20:31:52.563 SERIAL « 0x010c0004001a063105042206f00f (14 bytes) 20:31:52.564 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:52.565 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 177.6 => 177.6 [Endpoint 0] 20:31:52.566 SERIAL » [ACK] (0x06) 20:31:52.567 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 177.6 20:31:52.702 SERIAL « 0x0111000400150b861203043d00103101000a70 (19 bytes) 20:31:52.703 CNTRLR [Node 021] [+] [Version] libraryType: 3 [Endpoint 0] 20:31:52.704 CNTRLR [Node 021] [+] [Version] protocolVersion: "4.61" [Endpoint 0] 20:31:52.704 CNTRLR [Node 021] [+] [Version] firmwareVersions: 0.16 [Endpoint 0] 20:31:52.705 SERIAL » [ACK] (0x06) 20:31:52.706 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[VersionCCReport] library type: Enhanced Slave protocol version: 4.61 firmware versions: 0.16 20:31:52.755 SERIAL « 0x01070013500001b60c (9 bytes) 20:31:52.756 SERIAL » [ACK] (0x06) 20:31:52.757 DRIVER « [REQ] [SendData] callback id: 80 transmit status: OK 20:31:52.935 SERIAL « 0x010c0004001a06310504220a7586 (14 bytes) 20:31:52.936 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:52.937 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 177.6 => 267.7 [Endpoint 0] 20:31:52.937 SERIAL » [ACK] (0x06) 20:31:52.938 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 267.7 20:31:54.360 CNTRLR [Node 021] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 20:31:54.867 SERIAL » 0x0109001315028611255010 (11 bytes) 20:31:54.867 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 80 └─[VersionCCGet] 20:31:54.868 SERIAL « [ACK] (0x06) 20:31:54.872 SERIAL « 0x0104011301e8 (6 bytes) 20:31:54.873 SERIAL » [ACK] (0x06) 20:31:54.873 DRIVER « [RES] [SendData] was sent: true 20:31:56.292 SERIAL « 0x010c0004001a06310504220fb741 (14 bytes) 20:31:56.293 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:56.294 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 267.7 => 402.3 [Endpoint 0] 20:31:56.294 SERIAL » [ACK] (0x06) 20:31:56.295 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 402.3 20:31:58.709 SERIAL « 0x01070013500001803a (9 bytes) 20:31:58.710 SERIAL » [ACK] (0x06) 20:31:58.711 DRIVER « [REQ] [SendData] callback id: 80 transmit status: OK 20:31:58.907 SERIAL « 0x0111000400150b861203043d00103101000a70 (19 bytes) 20:31:58.908 CNTRLR [Node 021] [~] [Version] libraryType: 3 => 3 [Endpoint 0] 20:31:58.908 CNTRLR [Node 021] [~] [Version] protocolVersion: "4.61" => "4.61" [Endpoint 0] 20:31:58.909 CNTRLR [Node 021] [~] [Version] firmwareVersions: 0.16 => 0.16 [Endpoint 0] 20:31:58.910 SERIAL » [ACK] (0x06) 20:31:58.911 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[VersionCCReport] library type: Enhanced Slave protocol version: 4.61 firmware versions: 0.16 20:31:58.915 SERIAL » 0x0109001316028611255112 (11 bytes) 20:31:58.915 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 81 └─[VersionCCGet] 20:31:58.916 CNTRLR « [Node 021] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 4.61 firmware versions: 0.16 20:31:58.916 CNTRLR » [Node 021] querying CC versions... 20:31:58.916 CNTRLR » [Node 021] querying the CC version for Manufacturer Specific (0x72)... 20:31:58.923 SERIAL « [ACK] (0x06) 20:31:58.924 SERIAL « 0x0104011301e8 (6 bytes) 20:31:58.924 SERIAL » [ACK] (0x06) 20:31:58.925 DRIVER « [RES] [SendData] was sent: true 20:31:59.003 SERIAL « 0x010c0004001a06310504220fb741 (14 bytes) 20:31:59.004 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:59.005 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 402.3 => 402.3 [Endpoint 0] 20:31:59.005 SERIAL » [ACK] (0x06) 20:31:59.007 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 402.3 20:31:59.476 SERIAL « 0x010c0004001a063105042206ba45 (14 bytes) 20:31:59.477 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:31:59.478 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 402.3 => 172.2 [Endpoint 0] 20:31:59.479 SERIAL » [ACK] (0x06) 20:31:59.480 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 172.2 20:32:01.995 SERIAL « 0x010c0004001a063105042206ba45 (14 bytes) 20:32:01.996 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:32:01.999 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 172.2 => 172.2 [Endpoint 0] 20:32:01.999 SERIAL » [ACK] (0x06) 20:32:02.000 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 172.2 20:32:02.087 SERIAL « 0x010700135100013d86 (9 bytes) 20:32:02.088 SERIAL » [ACK] (0x06) 20:32:02.088 DRIVER « [REQ] [SendData] callback id: 81 transmit status: OK 20:32:02.186 SERIAL « 0x0111000400160b861203043d000f310100096f (19 bytes) 20:32:02.187 CNTRLR [Node 022] [+] [Version] libraryType: 3 [Endpoint 0] 20:32:02.187 CNTRLR [Node 022] [+] [Version] protocolVersion: "4.61" [Endpoint 0] 20:32:02.188 CNTRLR [Node 022] [+] [Version] firmwareVersions: 0.15 [Endpoint 0] 20:32:02.188 SERIAL » [ACK] (0x06) 20:32:02.190 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[VersionCCReport] library type: Enhanced Slave protocol version: 4.61 firmware versions: 0.15 20:32:02.193 SERIAL » 0x0109001317028611255210 (11 bytes) 20:32:02.194 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 82 └─[VersionCCGet] 20:32:02.196 CNTRLR « [Node 022] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 4.61 firmware versions: 0.15 20:32:02.196 CNTRLR » [Node 022] querying CC versions... 20:32:02.196 CNTRLR » [Node 022] querying the CC version for Manufacturer Specific (0x72)... 20:32:02.200 SERIAL « [ACK] (0x06) 20:32:02.205 SERIAL « 0x0104011301e8 (6 bytes) 20:32:02.205 SERIAL » [ACK] (0x06) 20:32:02.207 DRIVER « [RES] [SendData] was sent: true 20:32:03.651 SERIAL « 0x01070013520000922b (9 bytes) 20:32:03.651 SERIAL » [ACK] (0x06) 20:32:03.652 DRIVER « [REQ] [SendData] callback id: 82 transmit status: OK 20:32:03.738 SERIAL « 0x0111000400170b861203043d000f310100096e (19 bytes) 20:32:03.739 CNTRLR [Node 023] [+] [Version] libraryType: 3 [Endpoint 0] 20:32:03.739 CNTRLR [Node 023] [+] [Version] protocolVersion: "4.61" [Endpoint 0] 20:32:03.739 CNTRLR [Node 023] [+] [Version] firmwareVersions: 0.15 [Endpoint 0] 20:32:03.739 SERIAL » [ACK] (0x06) 20:32:03.740 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[VersionCCReport] library type: Enhanced Slave protocol version: 4.61 firmware versions: 0.15 20:32:03.743 SERIAL » 0x010900131802861125531e (11 bytes) 20:32:03.743 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 83 └─[VersionCCGet] 20:32:03.743 CNTRLR « [Node 023] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 4.61 firmware versions: 0.15 20:32:03.743 CNTRLR » [Node 023] querying CC versions... 20:32:03.743 CNTRLR » [Node 023] querying the CC version for Manufacturer Specific (0x72)... 20:32:03.745 SERIAL « [ACK] (0x06) 20:32:03.748 SERIAL « 0x0104011301e8 (6 bytes) 20:32:03.748 SERIAL » [ACK] (0x06) 20:32:03.749 DRIVER « [RES] [SendData] was sent: true 20:32:03.961 SERIAL « 0x010c0004001a06310504220cf207 (14 bytes) 20:32:03.962 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:32:03.963 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 172.2 => 331.4 [Endpoint 0] 20:32:03.964 SERIAL » [ACK] (0x06) 20:32:03.966 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 331.4 20:32:05.473 SERIAL « 0x01070013530000ad15 (9 bytes) 20:32:05.473 SERIAL » [ACK] (0x06) 20:32:05.474 DRIVER « [REQ] [SendData] callback id: 83 transmit status: OK 20:32:05.554 SERIAL « 0x0111000400180b861203043d000f3101000961 (19 bytes) 20:32:05.555 CNTRLR [Node 024] [+] [Version] libraryType: 3 [Endpoint 0] 20:32:05.556 CNTRLR [Node 024] [+] [Version] protocolVersion: "4.61" [Endpoint 0] 20:32:05.556 CNTRLR [Node 024] [+] [Version] firmwareVersions: 0.15 [Endpoint 0] 20:32:05.557 SERIAL » [ACK] (0x06) 20:32:05.560 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[VersionCCReport] library type: Enhanced Slave protocol version: 4.61 firmware versions: 0.15 20:32:05.561 SERIAL » 0x010900131a02861125541b (11 bytes) 20:32:05.563 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 84 └─[VersionCCGet] 20:32:05.563 CNTRLR « [Node 024] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 4.61 firmware versions: 0.15 20:32:05.563 CNTRLR » [Node 024] querying CC versions... 20:32:05.563 CNTRLR » [Node 024] querying the CC version for Manufacturer Specific (0x72)... 20:32:05.566 SERIAL « [ACK] (0x06) 20:32:05.568 SERIAL « 0x0104011301e8 (6 bytes) 20:32:05.568 SERIAL » [ACK] (0x06) 20:32:05.568 DRIVER « [RES] [SendData] was sent: true 20:32:05.769 SERIAL « 0x0107001354000014ab (9 bytes) 20:32:05.770 SERIAL » [ACK] (0x06) 20:32:05.771 DRIVER « [REQ] [SendData] callback id: 84 transmit status: OK 20:32:05.907 SERIAL « 0x01110004001a0b861203041803020201030273 (19 bytes) 20:32:05.908 CNTRLR [Node 026] [+] [Version] libraryType: 3 [Endpoint 0] 20:32:05.909 CNTRLR [Node 026] [+] [Version] protocolVersion: "4.24" [Endpoint 0] 20:32:05.910 CNTRLR [Node 026] [+] [Version] firmwareVersions: 3.2 [Endpoint 0] 20:32:05.910 SERIAL » [ACK] (0x06) 20:32:05.911 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[VersionCCReport] library type: Enhanced Slave protocol version: 4.24 firmware versions: 3.2 20:32:05.916 SERIAL » 0x010900131c02861125551c (11 bytes) 20:32:05.917 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 85 └─[VersionCCGet] 20:32:05.917 CNTRLR « [Node 026] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 4.24 firmware versions: 3.2 20:32:05.917 CNTRLR » [Node 026] querying CC versions... 20:32:05.918 CNTRLR » [Node 026] querying the CC version for Binary Switch (0x25)... 20:32:05.922 SERIAL « [ACK] (0x06) 20:32:05.924 SERIAL « 0x0104011301e8 (6 bytes) 20:32:05.924 SERIAL » [ACK] (0x06) 20:32:05.926 DRIVER « [RES] [SendData] was sent: true 20:32:06.035 SERIAL « 0x010700135500000cb2 (9 bytes) 20:32:06.035 SERIAL » [ACK] (0x06) 20:32:06.036 DRIVER « [REQ] [SendData] callback id: 85 transmit status: OK 20:32:06.046 SERIAL « 0x01110004001c0b861203041803020201030275 (19 bytes) 20:32:06.046 CNTRLR [Node 028] [+] [Version] libraryType: 3 [Endpoint 0] 20:32:06.047 CNTRLR [Node 028] [+] [Version] protocolVersion: "4.24" [Endpoint 0] 20:32:06.048 CNTRLR [Node 028] [+] [Version] firmwareVersions: 3.2 [Endpoint 0] 20:32:06.048 SERIAL » [ACK] (0x06) 20:32:06.050 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[VersionCCReport] library type: Enhanced Slave protocol version: 4.24 firmware versions: 3.2 20:32:06.053 SERIAL » 0x010a00130303861385255685 (12 bytes) 20:32:06.054 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 86 └─[VersionCCCommandClassGet] CC: Association 20:32:06.054 CNTRLR « [Node 028] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 4.24 firmware versions: 3.2 20:32:06.054 CNTRLR » [Node 028] querying CC versions... 20:32:06.055 CNTRLR » [Node 028] querying the CC version for Binary Switch (0x25)... 20:32:06.059 SERIAL « [ACK] (0x06) 20:32:06.062 SERIAL « 0x0104011301e8 (6 bytes) 20:32:06.062 SERIAL » [ACK] (0x06) 20:32:06.064 DRIVER « [RES] [SendData] was sent: true 20:32:06.079 SERIAL « 0x0107001356000002bf (9 bytes) 20:32:06.079 SERIAL » [ACK] (0x06) 20:32:06.080 DRIVER « [REQ] [SendData] callback id: 86 transmit status: OK 20:32:06.091 SERIAL « 0x010a000400030486148502e3 (12 bytes) 20:32:06.092 SERIAL » [ACK] (0x06) 20:32:06.093 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association version: 2 20:32:06.098 SERIAL » 0x010a00130503861372255775 (12 bytes) 20:32:06.098 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 87 └─[VersionCCCommandClassGet] CC: Manufacturer Specific 20:32:06.099 CNTRLR [Node 003] supports CC Association (0x85) in version 2 20:32:06.099 CNTRLR » [Node 003] querying the CC version for Association Group Information (0x59). .. 20:32:06.102 SERIAL « [ACK] (0x06) 20:32:06.103 SERIAL « 0x0104011301e8 (6 bytes) 20:32:06.104 SERIAL » [ACK] (0x06) 20:32:06.104 DRIVER « [RES] [SendData] was sent: true 20:32:06.119 SERIAL « 0x0107001357000001bd (9 bytes) 20:32:06.119 SERIAL » [ACK] (0x06) 20:32:06.120 DRIVER « [REQ] [SendData] callback id: 87 transmit status: OK 20:32:06.128 SERIAL « 0x010a00040005048614720212 (12 bytes) 20:32:06.129 SERIAL » [ACK] (0x06) 20:32:06.130 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 2 20:32:06.134 SERIAL » 0x010a00130603861372255879 (12 bytes) 20:32:06.135 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 88 └─[VersionCCCommandClassGet] CC: Manufacturer Specific 20:32:06.135 CNTRLR [Node 005] supports CC Manufacturer Specific (0x72) in version 2 20:32:06.135 CNTRLR [Node 005] skipping query for Device Reset Locally (0x5a) because max implem ented version is 1 20:32:06.136 CNTRLR [Node 005] skipping query for Powerlevel (0x73) because max implemented vers ion is 0 20:32:06.136 CNTRLR » [Node 005] querying the CC version for Association (0x85)... 20:32:06.139 SERIAL « [ACK] (0x06) 20:32:06.140 SERIAL « 0x0104011301e8 (6 bytes) 20:32:06.141 SERIAL » [ACK] (0x06) 20:32:06.141 DRIVER « [RES] [SendData] was sent: true 20:32:06.155 SERIAL « 0x0107001358000002b1 (9 bytes) 20:32:06.156 SERIAL » [ACK] (0x06) 20:32:06.156 DRIVER « [REQ] [SendData] callback id: 88 transmit status: OK 20:32:06.165 SERIAL « 0x010a00040006048614720211 (12 bytes) 20:32:06.166 SERIAL » [ACK] (0x06) 20:32:06.167 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 2 20:32:06.172 SERIAL » 0x010a0013020386137225597c (12 bytes) 20:32:06.173 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 89 └─[VersionCCCommandClassGet] CC: Manufacturer Specific 20:32:06.173 CNTRLR [Node 006] supports CC Manufacturer Specific (0x72) in version 2 20:32:06.174 CNTRLR [Node 006] skipping query for Device Reset Locally (0x5a) because max implem ented version is 1 20:32:06.174 CNTRLR [Node 006] skipping query for Powerlevel (0x73) because max implemented vers ion is 0 20:32:06.174 CNTRLR » [Node 006] querying the CC version for Association (0x85)... 20:32:06.178 SERIAL « [ACK] (0x06) 20:32:06.180 SERIAL « 0x0104011301e8 (6 bytes) 20:32:06.180 SERIAL » [ACK] (0x06) 20:32:06.181 DRIVER « [RES] [SendData] was sent: true 20:32:06.198 SERIAL « 0x0107001359000002b0 (9 bytes) 20:32:06.198 SERIAL » [ACK] (0x06) 20:32:06.199 DRIVER « [REQ] [SendData] callback id: 89 transmit status: OK 20:32:06.225 SERIAL « 0x010a00040002048614720215 (12 bytes) 20:32:06.225 SERIAL » [ACK] (0x06) 20:32:06.226 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 2 20:32:06.229 SERIAL » 0x010a00131303861325255a39 (12 bytes) 20:32:06.229 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 90 └─[VersionCCCommandClassGet] CC: Binary Switch 20:32:06.230 CNTRLR [Node 002] supports CC Manufacturer Specific (0x72) in version 2 20:32:06.230 CNTRLR [Node 002] skipping query for Security (0x98) because max implemented versio n is 1 20:32:06.230 CNTRLR [Node 002] skipping query for Device Reset Locally (0x5a) because max implem ented version is 1 20:32:06.230 CNTRLR » [Node 002] querying the CC version for Association (0x85)... 20:32:06.233 SERIAL « [ACK] (0x06) 20:32:06.235 SERIAL « 0x0104011301e8 (6 bytes) 20:32:06.235 SERIAL » [ACK] (0x06) 20:32:06.236 DRIVER « [RES] [SendData] was sent: true 20:32:06.376 SERIAL « 0x010700135a00000ebf (9 bytes) 20:32:06.377 SERIAL » [ACK] (0x06) 20:32:06.377 DRIVER « [REQ] [SendData] callback id: 90 transmit status: OK 20:32:06.505 SERIAL « 0x010a00040013048614250150 (12 bytes) 20:32:06.506 SERIAL » [ACK] (0x06) 20:32:06.506 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Binary Switch version: 1 20:32:06.509 SERIAL » 0x010a0013120386135e255b42 (12 bytes) 20:32:06.510 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 91 └─[VersionCCCommandClassGet] CC: Z-Wave Plus Info 20:32:06.510 CNTRLR [Node 019] supports CC Binary Switch (0x25) in version 1 20:32:06.510 CNTRLR [Node 019] skipping query for All Switch (0x27) because max implemented vers ion is 0 20:32:06.511 CNTRLR » [Node 019] querying the CC version for Z-Wave Plus Info (0x5e)... 20:32:06.514 SERIAL « [ACK] (0x06) 20:32:06.515 SERIAL « 0x0104011301e8 (6 bytes) 20:32:06.516 SERIAL » [ACK] (0x06) 20:32:06.516 DRIVER « [RES] [SendData] was sent: true 20:32:06.634 SERIAL « 0x010700135b00000cbc (9 bytes) 20:32:06.635 SERIAL » [ACK] (0x06) 20:32:06.635 DRIVER « [REQ] [SendData] callback id: 91 transmit status: OK 20:32:06.644 SERIAL « 0x010a000400120486145e0229 (12 bytes) 20:32:06.645 SERIAL » [ACK] (0x06) 20:32:06.646 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Z-Wave Plus Info version: 2 20:32:06.651 SERIAL » 0x010a00131403861325255c38 (12 bytes) 20:32:06.652 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 92 └─[VersionCCCommandClassGet] CC: Binary Switch 20:32:06.652 CNTRLR [Node 018] supports CC Z-Wave Plus Info (0x5e) in version 2 20:32:06.652 CNTRLR » [Node 018] querying the CC version for Version (0x86)... 20:32:06.655 SERIAL « [ACK] (0x06) 20:32:06.657 SERIAL « 0x0104011301e8 (6 bytes) 20:32:06.657 SERIAL » [ACK] (0x06) 20:32:06.658 DRIVER « [RES] [SendData] was sent: true 20:32:06.677 SERIAL « 0x010700135c000002b5 (9 bytes) 20:32:06.677 SERIAL » [ACK] (0x06) 20:32:06.678 DRIVER « [REQ] [SendData] callback id: 92 transmit status: OK 20:32:06.704 SERIAL « 0x010a00040014048614250157 (12 bytes) 20:32:06.705 SERIAL » [ACK] (0x06) 20:32:06.705 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Binary Switch version: 1 20:32:06.717 SERIAL » 0x010a00131503861372255d6f (12 bytes) 20:32:06.718 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 93 └─[VersionCCCommandClassGet] CC: Manufacturer Specific 20:32:06.718 CNTRLR [Node 020] supports CC Binary Switch (0x25) in version 1 20:32:06.719 CNTRLR [Node 020] skipping query for All Switch (0x27) because max implemented vers ion is 0 20:32:06.719 CNTRLR » [Node 020] querying the CC version for Z-Wave Plus Info (0x5e)... 20:32:06.723 SERIAL « [ACK] (0x06) 20:32:06.725 SERIAL « 0x0104011301e8 (6 bytes) 20:32:06.725 SERIAL » [ACK] (0x06) 20:32:06.725 DRIVER « [RES] [SendData] was sent: true 20:32:08.108 SERIAL « 0x010700135d00008a3c (9 bytes) 20:32:08.108 SERIAL » [ACK] (0x06) 20:32:08.109 DRIVER « [REQ] [SendData] callback id: 93 transmit status: OK 20:32:08.184 SERIAL « 0x010a00040015048614720101 (12 bytes) 20:32:08.185 SERIAL » [ACK] (0x06) 20:32:08.186 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 1 20:32:08.189 SERIAL » 0x010a00131603861372255e6f (12 bytes) 20:32:08.189 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 94 └─[VersionCCCommandClassGet] CC: Manufacturer Specific 20:32:08.189 CNTRLR [Node 021] supports CC Manufacturer Specific (0x72) in version 1 20:32:08.190 CNTRLR » [Node 021] querying the CC version for Thermostat Mode (0x40)... 20:32:08.191 SERIAL « [ACK] (0x06) 20:32:08.195 SERIAL « 0x0104011301e8 (6 bytes) 20:32:08.195 SERIAL » [ACK] (0x06) 20:32:08.196 DRIVER « [RES] [SendData] was sent: true 20:32:09.629 SERIAL « 0x010700135e00008f3a (9 bytes) 20:32:09.629 SERIAL » [ACK] (0x06) 20:32:09.630 DRIVER « [REQ] [SendData] callback id: 94 transmit status: OK 20:32:09.712 SERIAL « 0x010a00040016048614720102 (12 bytes) 20:32:09.713 SERIAL » [ACK] (0x06) 20:32:09.714 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 1 20:32:09.717 SERIAL » 0x010a00131703861372255f6f (12 bytes) 20:32:09.717 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 95 └─[VersionCCCommandClassGet] CC: Manufacturer Specific 20:32:09.717 CNTRLR [Node 022] supports CC Manufacturer Specific (0x72) in version 1 20:32:09.717 CNTRLR » [Node 022] querying the CC version for Thermostat Mode (0x40)... 20:32:09.719 SERIAL « [ACK] (0x06) 20:32:09.722 SERIAL « 0x0104011301e8 (6 bytes) 20:32:09.723 SERIAL » [ACK] (0x06) 20:32:09.723 DRIVER « [RES] [SendData] was sent: true 20:32:11.174 SERIAL « 0x010700135f00009226 (9 bytes) 20:32:11.175 SERIAL » [ACK] (0x06) 20:32:11.175 DRIVER « [REQ] [SendData] callback id: 95 transmit status: OK 20:32:11.252 SERIAL « 0x010a00040017048614720103 (12 bytes) 20:32:11.253 SERIAL » [ACK] (0x06) 20:32:11.253 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 1 20:32:11.256 SERIAL » 0x010a0013180386137225605f (12 bytes) 20:32:11.257 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 96 └─[VersionCCCommandClassGet] CC: Manufacturer Specific 20:32:11.257 CNTRLR [Node 023] supports CC Manufacturer Specific (0x72) in version 1 20:32:11.257 CNTRLR » [Node 023] querying the CC version for Thermostat Mode (0x40)... 20:32:11.260 SERIAL « [ACK] (0x06) 20:32:11.263 SERIAL « 0x0104011301e8 (6 bytes) 20:32:11.263 SERIAL » [ACK] (0x06) 20:32:11.264 DRIVER « [RES] [SendData] was sent: true 20:32:11.586 SERIAL « 0x010c0004001306310504220000f0 (14 bytes) 20:32:11.590 CNTRLR [Node 019] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:32:11.591 CNTRLR [Node 019] [+] [Multilevel Sensor] Power: 0 [Endpoint 0] 20:32:11.591 SERIAL » [ACK] (0x06) 20:32:11.592 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 20:32:16.714 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:32:16.715 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:32:16.716 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:32:16.717 SERIAL » [ACK] (0x06) 20:32:16.719 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:32:16.801 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:32:16.802 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:32:16.803 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:32:16.804 SERIAL » [ACK] (0x06) 20:32:16.805 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:32:16.831 SERIAL « 0x010a0004001804861472010c (12 bytes) 20:32:16.832 SERIAL » [ACK] (0x06) 20:32:16.832 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 1 20:32:16.892 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:32:16.893 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:32:16.893 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:32:16.894 SERIAL » [ACK] (0x06) 20:32:16.895 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:32:18.215 SERIAL « 0x010a0004001804861472010c (12 bytes) 20:32:18.216 SERIAL » [ACK] (0x06) 20:32:18.217 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 1 20:32:18.269 SERIAL « 0x01070013600002bd34 (9 bytes) 20:32:18.269 SERIAL » [ACK] (0x06) 20:32:18.270 DRIVER « [REQ] [SendData] callback id: 96 transmit status: OK 20:32:18.487 SERIAL « 0x010c0004001a06310504220749b7 (14 bytes) 20:32:18.488 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:32:18.488 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 331.4 => 186.5 [Endpoint 0] 20:32:18.489 SERIAL » [ACK] (0x06) 20:32:18.490 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 186.5 20:32:18.963 SERIAL « 0x010c0004001a063105042209d626 (14 bytes) 20:32:18.964 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:32:18.964 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 186.5 => 251.8 [Endpoint 0] 20:32:18.967 SERIAL » [ACK] (0x06) 20:32:18.968 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 251.8 20:32:19.873 CNTRLR [Node 024] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 20:32:20.376 SERIAL » 0x010a0013180386137225605f (12 bytes) 20:32:20.377 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 96 └─[VersionCCCommandClassGet] CC: Manufacturer Specific 20:32:20.378 SERIAL « [ACK] (0x06) 20:32:20.383 SERIAL « 0x0104011301e8 (6 bytes) 20:32:20.383 SERIAL » [ACK] (0x06) 20:32:20.383 DRIVER « [RES] [SendData] was sent: true 20:32:21.804 SERIAL « 0x010c0004001a06310504220f0bfd (14 bytes) 20:32:21.804 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:32:21.805 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 251.8 => 385.1 [Endpoint 0] 20:32:21.805 SERIAL » [ACK] (0x06) 20:32:21.806 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 385.1 20:32:21.828 SERIAL « 0x01070013600000911a (9 bytes) 20:32:21.828 SERIAL » [ACK] (0x06) 20:32:21.828 DRIVER « [REQ] [SendData] callback id: 96 transmit status: OK 20:32:22.008 SERIAL « 0x010c0004001a06310504220742bc (14 bytes) 20:32:22.009 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:32:22.010 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 385.1 => 185.8 [Endpoint 0] 20:32:22.010 SERIAL » [ACK] (0x06) 20:32:22.011 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 185.8 20:32:22.193 SERIAL « 0x010a0004001804861472010c (12 bytes) 20:32:22.194 SERIAL » [ACK] (0x06) 20:32:22.195 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 1 20:32:22.198 SERIAL » 0x010a00131a0386132525610b (12 bytes) 20:32:22.200 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 97 └─[VersionCCCommandClassGet] CC: Binary Switch 20:32:22.200 CNTRLR [Node 024] supports CC Manufacturer Specific (0x72) in version 1 20:32:22.201 CNTRLR » [Node 024] querying the CC version for Thermostat Mode (0x40)... 20:32:22.204 SERIAL « [ACK] (0x06) 20:32:22.205 SERIAL « 0x0104011301e8 (6 bytes) 20:32:22.206 SERIAL » [ACK] (0x06) 20:32:22.206 DRIVER « [RES] [SendData] was sent: true 20:32:22.621 SERIAL « 0x010700136100002aa0 (9 bytes) 20:32:22.622 SERIAL » [ACK] (0x06) 20:32:22.622 DRIVER « [REQ] [SendData] callback id: 97 transmit status: OK 20:32:22.940 SERIAL « 0x010a0004001a048614250159 (12 bytes) 20:32:22.940 SERIAL » [ACK] (0x06) 20:32:22.941 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Binary Switch version: 1 20:32:22.944 SERIAL » 0x010a00131c0386132525620e (12 bytes) 20:32:22.945 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 98 └─[VersionCCCommandClassGet] CC: Binary Switch 20:32:22.945 CNTRLR [Node 026] supports CC Binary Switch (0x25) in version 1 20:32:22.945 CNTRLR [Node 026] skipping query for All Switch (0x27) because max implemented vers ion is 0 20:32:22.945 CNTRLR » [Node 026] querying the CC version for Z-Wave Plus Info (0x5e)... 20:32:22.946 SERIAL « [ACK] (0x06) 20:32:22.950 SERIAL « 0x0104011301e8 (6 bytes) 20:32:22.950 SERIAL » [ACK] (0x06) 20:32:22.950 DRIVER « [RES] [SendData] was sent: true 20:32:23.114 SERIAL « 0x010c0004001a06310504220a45b6 (14 bytes) 20:32:23.115 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:32:23.116 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 185.8 => 262.9 [Endpoint 0] 20:32:23.116 SERIAL » [ACK] (0x06) 20:32:23.117 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 262.9 20:32:23.120 SERIAL « 0x010a0004001c04861425015f (12 bytes) 20:32:23.120 SERIAL » [ACK] (0x06) 20:32:23.121 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Binary Switch version: 1 20:32:23.255 SERIAL « 0x010700136200001f96 (9 bytes) 20:32:23.255 SERIAL » [ACK] (0x06) 20:32:23.256 DRIVER « [REQ] [SendData] callback id: 98 transmit status: OK 20:32:23.264 SERIAL « 0x010a0004001c04861425015f (12 bytes) 20:32:23.265 SERIAL » [ACK] (0x06) 20:32:23.266 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Binary Switch version: 1 20:32:23.269 SERIAL » 0x010a0013030386135925636c (12 bytes) 20:32:23.270 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 99 └─[VersionCCCommandClassGet] CC: Association Group Information 20:32:23.270 CNTRLR [Node 028] supports CC Binary Switch (0x25) in version 1 20:32:23.270 CNTRLR [Node 028] skipping query for All Switch (0x27) because max implemented vers ion is 0 20:32:23.270 CNTRLR » [Node 028] querying the CC version for Z-Wave Plus Info (0x5e)... 20:32:23.276 SERIAL « [ACK] (0x06) 20:32:23.277 SERIAL « 0x0104011301e8 (6 bytes) 20:32:23.277 SERIAL » [ACK] (0x06) 20:32:23.278 DRIVER « [RES] [SendData] was sent: true 20:32:23.294 SERIAL « 0x01070013630000028a (9 bytes) 20:32:23.295 SERIAL » [ACK] (0x06) 20:32:23.296 DRIVER « [REQ] [SendData] callback id: 99 transmit status: OK 20:32:23.307 SERIAL « 0x010a0004000304861459013c (12 bytes) 20:32:23.308 SERIAL » [ACK] (0x06) 20:32:23.308 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association Group Information version: 1 20:32:23.318 SERIAL » 0x010a001305038613852564b1 (12 bytes) 20:32:23.318 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 100 └─[VersionCCCommandClassGet] CC: Association 20:32:23.320 CNTRLR [Node 003] supports CC Association Group Information (0x59) in version 1 20:32:23.320 CNTRLR » [Node 003] querying the CC version for Configuration (0x70)... 20:32:23.322 SERIAL « [ACK] (0x06) 20:32:23.324 SERIAL « 0x0104011301e8 (6 bytes) 20:32:23.325 SERIAL » [ACK] (0x06) 20:32:23.325 DRIVER « [RES] [SendData] was sent: true 20:32:23.340 SERIAL « 0x01070013640000018e (9 bytes) 20:32:23.340 SERIAL » [ACK] (0x06) 20:32:23.340 DRIVER « [REQ] [SendData] callback id: 100 transmit status: OK 20:32:23.350 SERIAL « 0x010a000400050486148502e5 (12 bytes) 20:32:23.350 SERIAL » [ACK] (0x06) 20:32:23.350 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association version: 2 20:32:23.352 SERIAL » 0x010a001306038613852565b3 (12 bytes) 20:32:23.352 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 101 └─[VersionCCCommandClassGet] CC: Association 20:32:23.353 CNTRLR [Node 005] supports CC Association (0x85) in version 2 20:32:23.353 CNTRLR » [Node 005] querying the CC version for Association Group Information (0x59). .. 20:32:23.355 SERIAL « [ACK] (0x06) 20:32:23.358 SERIAL « 0x0104011301e8 (6 bytes) 20:32:23.358 SERIAL » [ACK] (0x06) 20:32:23.358 DRIVER « [RES] [SendData] was sent: true 20:32:23.373 SERIAL « 0x01070013650000028c (9 bytes) 20:32:23.373 SERIAL » [ACK] (0x06) 20:32:23.374 DRIVER « [REQ] [SendData] callback id: 101 transmit status: OK 20:32:23.383 SERIAL « 0x010a000400060486148502e6 (12 bytes) 20:32:23.383 SERIAL » [ACK] (0x06) 20:32:23.383 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association version: 2 20:32:23.385 SERIAL » 0x010a001302038613852566b4 (12 bytes) 20:32:23.385 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 102 └─[VersionCCCommandClassGet] CC: Association 20:32:23.386 CNTRLR [Node 006] supports CC Association (0x85) in version 2 20:32:23.386 CNTRLR » [Node 006] querying the CC version for Association Group Information (0x59). .. 20:32:23.399 SERIAL « [ACK] (0x06) 20:32:23.400 SERIAL « 0x0104011301e8 (6 bytes) 20:32:23.400 SERIAL » [ACK] (0x06) 20:32:23.401 DRIVER « [RES] [SendData] was sent: true 20:32:23.410 SERIAL « 0x01070013660000038e (9 bytes) 20:32:23.410 SERIAL » [ACK] (0x06) 20:32:23.410 DRIVER « [REQ] [SendData] callback id: 102 transmit status: OK 20:32:23.438 SERIAL « 0x010a000400020486148502e2 (12 bytes) 20:32:23.438 SERIAL » [ACK] (0x06) 20:32:23.438 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association version: 2 20:32:23.440 SERIAL » 0x010a0013130386135e25677f (12 bytes) 20:32:23.440 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 103 └─[VersionCCCommandClassGet] CC: Z-Wave Plus Info 20:32:23.440 CNTRLR [Node 002] supports CC Association (0x85) in version 2 20:32:23.440 CNTRLR » [Node 002] querying the CC version for Association Group Information (0x59). .. 20:32:23.442 SERIAL « [ACK] (0x06) 20:32:23.446 SERIAL « 0x0104011301e8 (6 bytes) 20:32:23.446 SERIAL » [ACK] (0x06) 20:32:23.446 DRIVER « [RES] [SendData] was sent: true 20:32:23.588 SERIAL « 0x010700136700000e82 (9 bytes) 20:32:23.589 SERIAL » [ACK] (0x06) 20:32:23.589 DRIVER « [REQ] [SendData] callback id: 103 transmit status: OK 20:32:23.715 SERIAL « 0x010a000400130486145e0228 (12 bytes) 20:32:23.715 SERIAL » [ACK] (0x06) 20:32:23.716 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Z-Wave Plus Info version: 2 20:32:23.721 SERIAL » 0x010a001312038613862568a9 (12 bytes) 20:32:23.722 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 104 └─[VersionCCCommandClassGet] CC: Version 20:32:23.722 CNTRLR [Node 019] supports CC Z-Wave Plus Info (0x5e) in version 2 20:32:23.722 CNTRLR [Node 019] skipping query for Application Status (0x22) because max implemen ted version is 0 20:32:23.722 CNTRLR » [Node 019] querying the CC version for Association (0x85)... 20:32:23.725 SERIAL « [ACK] (0x06) 20:32:23.727 SERIAL « 0x0104011301e8 (6 bytes) 20:32:23.727 SERIAL » [ACK] (0x06) 20:32:23.728 DRIVER « [RES] [SendData] was sent: true 20:32:23.944 SERIAL « 0x010700136800001695 (9 bytes) 20:32:23.944 SERIAL » [ACK] (0x06) 20:32:23.944 DRIVER « [REQ] [SendData] callback id: 104 transmit status: OK 20:32:23.954 SERIAL « 0x010a000400120486148602f1 (12 bytes) 20:32:23.955 SERIAL » [ACK] (0x06) 20:32:23.955 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 2 20:32:23.957 SERIAL » 0x010a0013140386135e256976 (12 bytes) 20:32:23.957 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 105 └─[VersionCCCommandClassGet] CC: Z-Wave Plus Info 20:32:23.957 CNTRLR [Node 018] supports CC Version (0x86) in version 2 20:32:23.957 CNTRLR » [Node 018] querying the CC version for Manufacturer Specific (0x72)... 20:32:23.959 SERIAL « [ACK] (0x06) 20:32:23.962 SERIAL « 0x0104011301e8 (6 bytes) 20:32:23.963 SERIAL » [ACK] (0x06) 20:32:23.963 DRIVER « [RES] [SendData] was sent: true 20:32:23.982 SERIAL « 0x010700136900000381 (9 bytes) 20:32:23.983 SERIAL » [ACK] (0x06) 20:32:23.983 DRIVER « [REQ] [SendData] callback id: 105 transmit status: OK 20:32:24.010 SERIAL « 0x010a000400140486145e022f (12 bytes) 20:32:24.010 SERIAL » [ACK] (0x06) 20:32:24.011 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Z-Wave Plus Info version: 2 20:32:24.014 SERIAL » 0x010a00131503861340256a6a (12 bytes) 20:32:24.015 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 106 └─[VersionCCCommandClassGet] CC: Thermostat Mode 20:32:24.015 CNTRLR [Node 020] supports CC Z-Wave Plus Info (0x5e) in version 2 20:32:24.015 CNTRLR » [Node 020] querying the CC version for Version (0x86)... 20:32:24.018 SERIAL « [ACK] (0x06) 20:32:24.020 SERIAL « 0x0104011301e8 (6 bytes) 20:32:24.020 SERIAL » [ACK] (0x06) 20:32:24.021 DRIVER « [RES] [SendData] was sent: true 20:32:25.387 SERIAL « 0x010700136a00008908 (9 bytes) 20:32:25.388 SERIAL » [ACK] (0x06) 20:32:25.389 DRIVER « [REQ] [SendData] callback id: 106 transmit status: OK 20:32:25.472 SERIAL « 0x010a00040015048614400331 (12 bytes) 20:32:25.473 SERIAL » [ACK] (0x06) 20:32:25.473 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Thermostat Mode version: 3 20:32:25.479 SERIAL » 0x010a00131603861340256b68 (12 bytes) 20:32:25.480 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 107 └─[VersionCCCommandClassGet] CC: Thermostat Mode 20:32:25.480 CNTRLR [Node 021] supports CC Thermostat Mode (0x40) in version 3 20:32:25.480 CNTRLR » [Node 021] querying the CC version for Thermostat Setpoint (0x43)... 20:32:25.482 SERIAL « [ACK] (0x06) 20:32:25.485 SERIAL « 0x0104011301e8 (6 bytes) 20:32:25.485 SERIAL » [ACK] (0x06) 20:32:25.485 DRIVER « [RES] [SendData] was sent: true 20:32:26.951 SERIAL « 0x010700136b00009313 (9 bytes) 20:32:26.952 SERIAL » [ACK] (0x06) 20:32:26.953 DRIVER « [REQ] [SendData] callback id: 107 transmit status: OK 20:32:27.036 SERIAL « 0x010a00040016048614400332 (12 bytes) 20:32:27.037 SERIAL » [ACK] (0x06) 20:32:27.038 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Thermostat Mode version: 3 20:32:27.041 SERIAL » 0x010a00131703861340256c6e (12 bytes) 20:32:27.041 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 108 └─[VersionCCCommandClassGet] CC: Thermostat Mode 20:32:27.041 CNTRLR [Node 022] supports CC Thermostat Mode (0x40) in version 3 20:32:27.042 CNTRLR » [Node 022] querying the CC version for Thermostat Setpoint (0x43)... 20:32:27.043 SERIAL « [ACK] (0x06) 20:32:27.047 SERIAL « 0x0104011301e8 (6 bytes) 20:32:27.047 SERIAL » [ACK] (0x06) 20:32:27.048 DRIVER « [RES] [SendData] was sent: true 20:32:28.511 SERIAL « 0x010700136c00009314 (9 bytes) 20:32:28.511 SERIAL » [ACK] (0x06) 20:32:28.512 DRIVER « [REQ] [SendData] callback id: 108 transmit status: OK 20:32:28.587 SERIAL « 0x010a00040017048614400333 (12 bytes) 20:32:28.588 SERIAL » [ACK] (0x06) 20:32:28.588 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Thermostat Mode version: 3 20:32:28.593 SERIAL » 0x010a00131803861340256d60 (12 bytes) 20:32:28.593 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 109 └─[VersionCCCommandClassGet] CC: Thermostat Mode 20:32:28.593 CNTRLR [Node 023] supports CC Thermostat Mode (0x40) in version 3 20:32:28.593 CNTRLR » [Node 023] querying the CC version for Thermostat Setpoint (0x43)... 20:32:28.594 SERIAL « [ACK] (0x06) 20:32:28.598 SERIAL « 0x0104011301e8 (6 bytes) 20:32:28.598 SERIAL » [ACK] (0x06) 20:32:28.599 DRIVER « [RES] [SendData] was sent: true 20:32:30.044 SERIAL « 0x010700136d00009117 (9 bytes) 20:32:30.044 SERIAL » [ACK] (0x06) 20:32:30.045 DRIVER « [REQ] [SendData] callback id: 109 transmit status: OK 20:32:30.124 SERIAL « 0x010a0004001804861440033c (12 bytes) 20:32:30.125 SERIAL » [ACK] (0x06) 20:32:30.126 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Thermostat Mode version: 3 20:32:30.129 SERIAL » 0x010a00131a0386135e256e7f (12 bytes) 20:32:30.129 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 110 └─[VersionCCCommandClassGet] CC: Z-Wave Plus Info 20:32:30.130 CNTRLR [Node 024] supports CC Thermostat Mode (0x40) in version 3 20:32:30.130 CNTRLR » [Node 024] querying the CC version for Thermostat Setpoint (0x43)... 20:32:30.131 SERIAL « [ACK] (0x06) 20:32:30.135 SERIAL « 0x0104011301e8 (6 bytes) 20:32:30.135 SERIAL » [ACK] (0x06) 20:32:30.136 DRIVER « [RES] [SendData] was sent: true 20:32:30.357 SERIAL « 0x010700136e00001693 (9 bytes) 20:32:30.357 SERIAL » [ACK] (0x06) 20:32:30.358 DRIVER « [REQ] [SendData] callback id: 110 transmit status: OK 20:32:30.485 SERIAL « 0x010a0004001a0486145e0221 (12 bytes) 20:32:30.486 SERIAL » [ACK] (0x06) 20:32:30.486 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Z-Wave Plus Info version: 2 20:32:30.490 SERIAL » 0x010a00131c0386135e256f78 (12 bytes) 20:32:30.490 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 111 └─[VersionCCCommandClassGet] CC: Z-Wave Plus Info 20:32:30.490 CNTRLR [Node 026] supports CC Z-Wave Plus Info (0x5e) in version 2 20:32:30.490 CNTRLR [Node 026] skipping query for Application Status (0x22) because max implemen ted version is 0 20:32:30.491 CNTRLR » [Node 026] querying the CC version for Association (0x85)... 20:32:30.493 SERIAL « [ACK] (0x06) 20:32:30.495 SERIAL « 0x0104011301e8 (6 bytes) 20:32:30.496 SERIAL » [ACK] (0x06) 20:32:30.496 DRIVER « [RES] [SendData] was sent: true 20:32:30.615 SERIAL « 0x010700136f00000c88 (9 bytes) 20:32:30.615 SERIAL » [ACK] (0x06) 20:32:30.616 DRIVER « [REQ] [SendData] callback id: 111 transmit status: OK 20:32:30.624 SERIAL « 0x010a0004001c0486145e0227 (12 bytes) 20:32:30.625 SERIAL » [ACK] (0x06) 20:32:30.626 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Z-Wave Plus Info version: 2 20:32:30.631 SERIAL » 0x010a00130303861370257056 (12 bytes) 20:32:30.631 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 112 └─[VersionCCCommandClassGet] CC: Configuration 20:32:30.632 CNTRLR [Node 028] supports CC Z-Wave Plus Info (0x5e) in version 2 20:32:30.632 CNTRLR [Node 028] skipping query for Application Status (0x22) because max implemen ted version is 0 20:32:30.632 CNTRLR » [Node 028] querying the CC version for Association (0x85)... 20:32:30.635 SERIAL « [ACK] (0x06) 20:32:30.637 SERIAL « 0x0104011301e8 (6 bytes) 20:32:30.637 SERIAL » [ACK] (0x06) 20:32:30.638 DRIVER « [RES] [SendData] was sent: true 20:32:30.656 SERIAL « 0x010700137000000299 (9 bytes) 20:32:30.659 SERIAL » [ACK] (0x06) 20:32:30.659 DRIVER « [REQ] [SendData] callback id: 112 transmit status: OK 20:32:30.669 SERIAL « 0x010a00040003048614700115 (12 bytes) 20:32:30.669 SERIAL » [ACK] (0x06) 20:32:30.669 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Configuration version: 1 20:32:30.670 SERIAL » 0x010a00130503861359257178 (12 bytes) 20:32:30.670 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 113 └─[VersionCCCommandClassGet] CC: Association Group Information 20:32:30.671 CNTRLR [Node 003] supports CC Configuration (0x70) in version 1 20:32:30.671 CNTRLR [Node 003] skipping query for CRC-16 Encapsulation (0x56) because max implem ented version is 1 20:32:30.671 CNTRLR [Node 003] skipping query for Device Reset Locally (0x5a) because max implem ented version is 1 20:32:30.671 CNTRLR » [Node 003] querying the CC version for Firmware Update Meta Data (0x7a)... 20:32:30.672 SERIAL « [ACK] (0x06) 20:32:30.676 SERIAL « 0x0104011301e8 (6 bytes) 20:32:30.676 SERIAL » [ACK] (0x06) 20:32:30.677 DRIVER « [RES] [SendData] was sent: true 20:32:30.692 SERIAL « 0x010700137100000298 (9 bytes) 20:32:30.692 SERIAL » [ACK] (0x06) 20:32:30.692 DRIVER « [REQ] [SendData] callback id: 113 transmit status: OK 20:32:30.700 SERIAL « 0x010a0004000504861459013a (12 bytes) 20:32:30.701 SERIAL » [ACK] (0x06) 20:32:30.701 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association Group Information version: 1 20:32:30.706 SERIAL » 0x010a00130603861359257278 (12 bytes) 20:32:30.707 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 114 └─[VersionCCCommandClassGet] CC: Association Group Information 20:32:30.707 CNTRLR [Node 005] supports CC Association Group Information (0x59) in version 1 20:32:30.707 CNTRLR » [Node 005] querying the CC version for Notification (0x71)... 20:32:30.709 SERIAL « [ACK] (0x06) 20:32:30.712 SERIAL « 0x0104011301e8 (6 bytes) 20:32:30.712 SERIAL » [ACK] (0x06) 20:32:30.712 DRIVER « [RES] [SendData] was sent: true 20:32:30.727 SERIAL « 0x01070013720000029b (9 bytes) 20:32:30.728 SERIAL » [ACK] (0x06) 20:32:30.728 DRIVER « [REQ] [SendData] callback id: 114 transmit status: OK 20:32:30.737 SERIAL « 0x010a00040006048614590139 (12 bytes) 20:32:30.737 SERIAL » [ACK] (0x06) 20:32:30.738 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association Group Information version: 1 20:32:30.740 SERIAL » 0x010a0013020386135925737d (12 bytes) 20:32:30.741 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 115 └─[VersionCCCommandClassGet] CC: Association Group Information 20:32:30.741 CNTRLR [Node 006] supports CC Association Group Information (0x59) in version 1 20:32:30.741 CNTRLR » [Node 006] querying the CC version for Notification (0x71)... 20:32:30.743 SERIAL « [ACK] (0x06) 20:32:30.746 SERIAL « 0x0104011301e8 (6 bytes) 20:32:30.747 SERIAL » [ACK] (0x06) 20:32:30.747 DRIVER « [RES] [SendData] was sent: true 20:32:30.947 SERIAL « 0x01070013730000148c (9 bytes) 20:32:30.949 SERIAL » [ACK] (0x06) 20:32:30.950 DRIVER « [REQ] [SendData] callback id: 115 transmit status: OK 20:32:30.974 SERIAL « 0x010a0004000204861459013d (12 bytes) 20:32:30.975 SERIAL » [ACK] (0x06) 20:32:30.976 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association Group Information version: 1 20:32:30.979 SERIAL » 0x010a001313038613852574b7 (12 bytes) 20:32:30.979 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 116 └─[VersionCCCommandClassGet] CC: Association 20:32:30.979 CNTRLR [Node 002] supports CC Association Group Information (0x59) in version 1 20:32:30.980 CNTRLR [Node 002] skipping query for Powerlevel (0x73) because max implemented vers ion is 0 20:32:30.980 CNTRLR » [Node 002] querying the CC version for Meter (0x32)... 20:32:30.982 SERIAL « [ACK] (0x06) 20:32:30.984 SERIAL « 0x0104011301e8 (6 bytes) 20:32:30.985 SERIAL » [ACK] (0x06) 20:32:30.985 DRIVER « [RES] [SendData] was sent: true 20:32:31.126 SERIAL « 0x010700137400000e91 (9 bytes) 20:32:31.126 SERIAL » [ACK] (0x06) 20:32:31.127 DRIVER « [REQ] [SendData] callback id: 116 transmit status: OK 20:32:31.255 SERIAL « 0x010a000400130486148502f3 (12 bytes) 20:32:31.255 SERIAL » [ACK] (0x06) 20:32:31.256 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association version: 2 20:32:31.258 SERIAL » 0x010a00131203861372257540 (12 bytes) 20:32:31.258 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 117 └─[VersionCCCommandClassGet] CC: Manufacturer Specific 20:32:31.258 CNTRLR [Node 019] supports CC Association (0x85) in version 2 20:32:31.258 CNTRLR » [Node 019] querying the CC version for Association Group Information (0x59). .. 20:32:31.260 SERIAL « [ACK] (0x06) 20:32:31.263 SERIAL « 0x0104011301e8 (6 bytes) 20:32:31.264 SERIAL » [ACK] (0x06) 20:32:31.264 DRIVER « [RES] [SendData] was sent: true 20:32:31.544 SERIAL « 0x010700137500001c82 (9 bytes) 20:32:31.545 SERIAL » [ACK] (0x06) 20:32:31.546 DRIVER « [REQ] [SendData] callback id: 117 transmit status: OK 20:32:31.554 SERIAL « 0x010a00040012048614720205 (12 bytes) 20:32:31.555 SERIAL » [ACK] (0x06) 20:32:31.556 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 2 20:32:31.559 SERIAL » 0x010a001314038613862576b1 (12 bytes) 20:32:31.560 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 118 └─[VersionCCCommandClassGet] CC: Version 20:32:31.560 CNTRLR [Node 018] supports CC Manufacturer Specific (0x72) in version 2 20:32:31.560 CNTRLR [Node 018] skipping query for Device Reset Locally (0x5a) because max implem ented version is 1 20:32:31.561 CNTRLR [Node 018] skipping query for Powerlevel (0x73) because max implemented vers ion is 0 20:32:31.561 CNTRLR » [Node 018] querying the CC version for Association (0x85)... 20:32:31.564 SERIAL « [ACK] (0x06) 20:32:31.565 SERIAL « 0x0104011301e8 (6 bytes) 20:32:31.565 SERIAL » [ACK] (0x06) 20:32:31.566 DRIVER « [RES] [SendData] was sent: true 20:32:31.585 SERIAL « 0x01070013760000029f (9 bytes) 20:32:31.585 SERIAL » [ACK] (0x06) 20:32:31.586 DRIVER « [REQ] [SendData] callback id: 118 transmit status: OK 20:32:31.611 SERIAL « 0x010a000400140486148602f7 (12 bytes) 20:32:31.614 SERIAL » [ACK] (0x06) 20:32:31.615 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 2 20:32:31.618 SERIAL » 0x010a00131503861343257774 (12 bytes) 20:32:31.619 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 119 └─[VersionCCCommandClassGet] CC: Thermostat Setpoint 20:32:31.619 CNTRLR [Node 020] supports CC Version (0x86) in version 2 20:32:31.619 CNTRLR » [Node 020] querying the CC version for Manufacturer Specific (0x72)... 20:32:31.623 SERIAL « [ACK] (0x06) 20:32:31.624 SERIAL « 0x0104011301e8 (6 bytes) 20:32:31.624 SERIAL » [ACK] (0x06) 20:32:31.625 DRIVER « [RES] [SendData] was sent: true 20:32:33.110 SERIAL « 0x010c0004001a063105042212c72c (14 bytes) 20:32:33.112 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:32:33.113 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 262.9 => 480.7 [Endpoint 0] 20:32:33.113 SERIAL » [ACK] (0x06) 20:32:33.114 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 480.7 20:32:34.274 SERIAL « 0x010c0004001a063105042212c72c (14 bytes) 20:32:34.275 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:32:34.276 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 480.7 => 480.7 [Endpoint 0] 20:32:34.277 SERIAL » [ACK] (0x06) 20:32:34.278 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 480.7 20:32:35.562 SERIAL « 0x010700137700018a17 (9 bytes) 20:32:35.562 SERIAL » [ACK] (0x06) 20:32:35.563 DRIVER « [REQ] [SendData] callback id: 119 transmit status: OK 20:32:35.708 SERIAL « 0x010c0004001a063105042212c72c (14 bytes) 20:32:35.708 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:32:35.709 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 480.7 => 480.7 [Endpoint 0] 20:32:35.710 SERIAL » [ACK] (0x06) 20:32:35.711 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 480.7 20:32:36.036 SERIAL « 0x010a00040015048614430332 (12 bytes) 20:32:36.036 SERIAL » [ACK] (0x06) 20:32:36.037 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Thermostat Setpoint version: 3 20:32:36.040 SERIAL » 0x010a00131603861343257878 (12 bytes) 20:32:36.041 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 120 └─[VersionCCCommandClassGet] CC: Thermostat Setpoint 20:32:36.041 CNTRLR [Node 021] supports CC Thermostat Setpoint (0x43) in version 3 20:32:36.041 CNTRLR » [Node 021] querying the CC version for Version (0x86)... 20:32:36.042 SERIAL « [ACK] (0x06) 20:32:36.046 SERIAL « 0x0104011301e8 (6 bytes) 20:32:36.046 SERIAL » [ACK] (0x06) 20:32:36.046 DRIVER « [RES] [SendData] was sent: true 20:32:37.553 SERIAL « 0x010700137800009704 (9 bytes) 20:32:37.553 SERIAL » [ACK] (0x06) 20:32:37.554 DRIVER « [REQ] [SendData] callback id: 120 transmit status: OK 20:32:37.635 SERIAL « 0x010a00040016048614430331 (12 bytes) 20:32:37.636 SERIAL » [ACK] (0x06) 20:32:37.636 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Thermostat Setpoint version: 3 20:32:37.639 SERIAL » 0x010a00131703861343257978 (12 bytes) 20:32:37.640 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 121 └─[VersionCCCommandClassGet] CC: Thermostat Setpoint 20:32:37.640 CNTRLR [Node 022] supports CC Thermostat Setpoint (0x43) in version 3 20:32:37.640 CNTRLR » [Node 022] querying the CC version for Version (0x86)... 20:32:37.643 SERIAL « [ACK] (0x06) 20:32:37.646 SERIAL « 0x0104011301e8 (6 bytes) 20:32:37.646 SERIAL » [ACK] (0x06) 20:32:37.650 DRIVER « [RES] [SendData] was sent: true 20:32:39.076 SERIAL « 0x010700137900008f1d (9 bytes) 20:32:39.077 SERIAL » [ACK] (0x06) 20:32:39.077 DRIVER « [REQ] [SendData] callback id: 121 transmit status: OK 20:32:39.159 SERIAL « 0x010a00040017048614430330 (12 bytes) 20:32:39.160 SERIAL » [ACK] (0x06) 20:32:39.160 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Thermostat Setpoint version: 3 20:32:39.167 SERIAL » 0x010a00131803861343257a74 (12 bytes) 20:32:39.167 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 122 └─[VersionCCCommandClassGet] CC: Thermostat Setpoint 20:32:39.167 CNTRLR [Node 023] supports CC Thermostat Setpoint (0x43) in version 3 20:32:39.168 CNTRLR » [Node 023] querying the CC version for Version (0x86)... 20:32:39.171 SERIAL « [ACK] (0x06) 20:32:39.172 SERIAL « 0x0104011301e8 (6 bytes) 20:32:39.173 SERIAL » [ACK] (0x06) 20:32:39.173 DRIVER « [RES] [SendData] was sent: true 20:32:40.631 SERIAL « 0x010700137a00009302 (9 bytes) 20:32:40.631 SERIAL » [ACK] (0x06) 20:32:40.632 DRIVER « [REQ] [SendData] callback id: 122 transmit status: OK 20:32:40.706 SERIAL « 0x010a0004001804861443033f (12 bytes) 20:32:40.707 SERIAL » [ACK] (0x06) 20:32:40.707 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Thermostat Setpoint version: 3 20:32:40.711 SERIAL » 0x010a00131a03861385257bb1 (12 bytes) 20:32:40.711 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 123 └─[VersionCCCommandClassGet] CC: Association 20:32:40.711 CNTRLR [Node 024] supports CC Thermostat Setpoint (0x43) in version 3 20:32:40.712 CNTRLR » [Node 024] querying the CC version for Version (0x86)... 20:32:40.713 SERIAL « [ACK] (0x06) 20:32:40.717 SERIAL « 0x0104011301e8 (6 bytes) 20:32:40.717 SERIAL » [ACK] (0x06) 20:32:40.717 DRIVER « [RES] [SendData] was sent: true 20:32:40.921 SERIAL « 0x010700137b00001585 (9 bytes) 20:32:40.922 SERIAL » [ACK] (0x06) 20:32:40.922 DRIVER « [REQ] [SendData] callback id: 123 transmit status: OK 20:32:41.150 SERIAL « 0x010a0004001a0486148502fa (12 bytes) 20:32:41.151 SERIAL » [ACK] (0x06) 20:32:41.152 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association version: 2 20:32:41.155 SERIAL » 0x010a00131c03861385257cb0 (12 bytes) 20:32:41.155 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 124 └─[VersionCCCommandClassGet] CC: Association 20:32:41.156 CNTRLR [Node 026] supports CC Association (0x85) in version 2 20:32:41.156 CNTRLR » [Node 026] querying the CC version for Association Group Information (0x59). .. 20:32:41.159 SERIAL « [ACK] (0x06) 20:32:41.161 SERIAL « 0x0104011301e8 (6 bytes) 20:32:41.161 SERIAL » [ACK] (0x06) 20:32:41.162 DRIVER « [RES] [SendData] was sent: true 20:32:41.284 SERIAL « 0x010700137c00000d9a (9 bytes) 20:32:41.285 SERIAL » [ACK] (0x06) 20:32:41.285 DRIVER « [REQ] [SendData] callback id: 124 transmit status: OK 20:32:41.295 SERIAL « 0x010a0004001c0486148502fc (12 bytes) 20:32:41.295 SERIAL » [ACK] (0x06) 20:32:41.296 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association version: 2 20:32:41.299 SERIAL » 0x010a0013030386137a257d51 (12 bytes) 20:32:41.300 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 125 └─[VersionCCCommandClassGet] CC: Firmware Update Meta Data 20:32:41.300 CNTRLR [Node 028] supports CC Association (0x85) in version 2 20:32:41.300 CNTRLR » [Node 028] querying the CC version for Association Group Information (0x59). .. 20:32:41.305 SERIAL « [ACK] (0x06) 20:32:41.308 SERIAL « 0x0104011301e8 (6 bytes) 20:32:41.308 SERIAL » [ACK] (0x06) 20:32:41.309 DRIVER « [RES] [SendData] was sent: true 20:32:41.328 SERIAL « 0x010700137d00000294 (9 bytes) 20:32:41.328 SERIAL » [ACK] (0x06) 20:32:41.329 DRIVER « [REQ] [SendData] callback id: 125 transmit status: OK 20:32:41.341 SERIAL « 0x010a000400030486147a031d (12 bytes) 20:32:41.341 SERIAL » [ACK] (0x06) 20:32:41.342 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Firmware Update Meta Data version: 3 20:32:41.345 SERIAL » 0x010a00130503861371257e5f (12 bytes) 20:32:41.346 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 126 └─[VersionCCCommandClassGet] CC: Notification 20:32:41.346 CNTRLR [Node 003] supports CC Firmware Update Meta Data (0x7a) in version 3 20:32:41.346 CNTRLR » [Node 003] querying the CC version for Manufacturer Specific (0x72)... 20:32:41.351 SERIAL « [ACK] (0x06) 20:32:41.352 SERIAL « 0x0104011301e8 (6 bytes) 20:32:41.353 SERIAL » [ACK] (0x06) 20:32:41.353 DRIVER « [RES] [SendData] was sent: true 20:32:41.367 SERIAL « 0x010700137e00000297 (9 bytes) 20:32:41.367 SERIAL » [ACK] (0x06) 20:32:41.368 DRIVER « [REQ] [SendData] callback id: 126 transmit status: OK 20:32:41.376 SERIAL « 0x010a00040005048614710112 (12 bytes) 20:32:41.377 SERIAL » [ACK] (0x06) 20:32:41.377 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Notification version: 1 20:32:41.381 SERIAL » 0x010a00130603861371257f5d (12 bytes) 20:32:41.381 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 127 └─[VersionCCCommandClassGet] CC: Notification 20:32:41.382 CNTRLR [Node 005] supports CC Notification (0x71) in version 1 20:32:41.382 CNTRLR » [Node 005] querying the CC version for Configuration (0x70)... 20:32:41.385 SERIAL « [ACK] (0x06) 20:32:41.387 SERIAL « 0x0104011301e8 (6 bytes) 20:32:41.387 SERIAL » [ACK] (0x06) 20:32:41.388 DRIVER « [RES] [SendData] was sent: true 20:32:41.402 SERIAL « 0x010700137f00000296 (9 bytes) 20:32:41.402 SERIAL » [ACK] (0x06) 20:32:41.403 DRIVER « [REQ] [SendData] callback id: 127 transmit status: OK 20:32:41.412 SERIAL « 0x010a00040006048614710111 (12 bytes) 20:32:41.412 SERIAL » [ACK] (0x06) 20:32:41.414 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Notification version: 1 20:32:41.423 SERIAL » 0x010a001302038613322580e5 (12 bytes) 20:32:41.424 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 128 └─[VersionCCCommandClassGet] CC: Meter 20:32:41.424 CNTRLR [Node 006] supports CC Notification (0x71) in version 1 20:32:41.424 CNTRLR » [Node 006] querying the CC version for Configuration (0x70)... 20:32:41.427 SERIAL « [ACK] (0x06) 20:32:41.429 SERIAL « 0x0104011301e8 (6 bytes) 20:32:41.429 SERIAL » [ACK] (0x06) 20:32:41.430 DRIVER « [RES] [SendData] was sent: true 20:32:41.449 SERIAL « 0x010700138000000269 (9 bytes) 20:32:41.449 SERIAL » [ACK] (0x06) 20:32:41.449 DRIVER « [REQ] [SendData] callback id: 128 transmit status: OK 20:32:41.476 SERIAL « 0x010a00040002048614320354 (12 bytes) 20:32:41.477 SERIAL » [ACK] (0x06) 20:32:41.477 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Meter version: 3 20:32:41.479 SERIAL » 0x010a0013130386135925819e (12 bytes) 20:32:41.479 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 129 └─[VersionCCCommandClassGet] CC: Association Group Information 20:32:41.479 CNTRLR [Node 002] supports CC Meter (0x32) in version 3 20:32:41.479 CNTRLR » [Node 002] querying the CC version for Configuration (0x70)... 20:32:41.480 SERIAL « [ACK] (0x06) 20:32:41.484 SERIAL « 0x0104011301e8 (6 bytes) 20:32:41.484 SERIAL » [ACK] (0x06) 20:32:41.485 DRIVER « [RES] [SendData] was sent: true 20:32:41.626 SERIAL « 0x010700138100000e64 (9 bytes) 20:32:41.627 SERIAL » [ACK] (0x06) 20:32:41.628 DRIVER « [REQ] [SendData] callback id: 129 transmit status: OK 20:32:41.755 SERIAL « 0x010a0004001304861459012c (12 bytes) 20:32:41.756 SERIAL » [ACK] (0x06) 20:32:41.756 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association Group Information version: 1 20:32:41.759 SERIAL » 0x010a00131203861385258240 (12 bytes) 20:32:41.759 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 130 └─[VersionCCCommandClassGet] CC: Association 20:32:41.760 CNTRLR [Node 019] supports CC Association Group Information (0x59) in version 1 20:32:41.760 CNTRLR » [Node 019] querying the CC version for Configuration (0x70)... 20:32:41.762 SERIAL « [ACK] (0x06) 20:32:41.765 SERIAL « 0x0104011301e8 (6 bytes) 20:32:41.766 SERIAL » [ACK] (0x06) 20:32:41.766 DRIVER « [RES] [SendData] was sent: true 20:32:41.884 SERIAL « 0x010700138200000c65 (9 bytes) 20:32:41.885 SERIAL » [ACK] (0x06) 20:32:41.885 DRIVER « [REQ] [SendData] callback id: 130 transmit status: OK 20:32:41.895 SERIAL « 0x010a000400120486148502f2 (12 bytes) 20:32:41.896 SERIAL » [ACK] (0x06) 20:32:41.896 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association version: 2 20:32:41.899 SERIAL » 0x010a001314038613722583b0 (12 bytes) 20:32:41.899 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 131 └─[VersionCCCommandClassGet] CC: Manufacturer Specific 20:32:41.900 CNTRLR [Node 018] supports CC Association (0x85) in version 2 20:32:41.900 CNTRLR » [Node 018] querying the CC version for Association Group Information (0x59). .. 20:32:41.904 SERIAL « [ACK] (0x06) 20:32:41.906 SERIAL « 0x0104011301e8 (6 bytes) 20:32:41.906 SERIAL » [ACK] (0x06) 20:32:41.906 DRIVER « [RES] [SendData] was sent: true 20:32:41.925 SERIAL « 0x01070013830000026a (9 bytes) 20:32:41.925 SERIAL » [ACK] (0x06) 20:32:41.926 DRIVER « [REQ] [SendData] callback id: 131 transmit status: OK 20:32:41.952 SERIAL « 0x010a00040014048614720203 (12 bytes) 20:32:41.953 SERIAL » [ACK] (0x06) 20:32:41.954 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 2 20:32:41.956 SERIAL » 0x010a00131503861386258442 (12 bytes) 20:32:41.957 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 132 └─[VersionCCCommandClassGet] CC: Version 20:32:41.957 CNTRLR [Node 020] supports CC Manufacturer Specific (0x72) in version 2 20:32:41.957 CNTRLR [Node 020] skipping query for Security (0x98) because max implemented versio n is 1 20:32:41.957 CNTRLR [Node 020] skipping query for Device Reset Locally (0x5a) because max implem ented version is 1 20:32:41.958 CNTRLR » [Node 020] querying the CC version for Association (0x85)... 20:32:41.960 SERIAL « [ACK] (0x06) 20:32:41.963 SERIAL « 0x0104011301e8 (6 bytes) 20:32:41.963 SERIAL » [ACK] (0x06) 20:32:41.964 DRIVER « [RES] [SendData] was sent: true 20:32:43.332 SERIAL « 0x010700138400008ae5 (9 bytes) 20:32:43.332 SERIAL » [ACK] (0x06) 20:32:43.333 DRIVER « [REQ] [SendData] callback id: 132 transmit status: OK 20:32:43.413 SERIAL « 0x010a000400150486148602f6 (12 bytes) 20:32:43.413 SERIAL » [ACK] (0x06) 20:32:43.414 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 2 20:32:43.418 SERIAL » 0x010a00131603861386258540 (12 bytes) 20:32:43.418 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 133 └─[VersionCCCommandClassGet] CC: Version 20:32:43.419 CNTRLR [Node 021] supports CC Version (0x86) in version 2 20:32:43.419 CNTRLR » [Node 021] querying the CC version for Z-Wave Plus Info (0x5e)... 20:32:43.421 SERIAL « [ACK] (0x06) 20:32:43.423 SERIAL « 0x0104011301e8 (6 bytes) 20:32:43.423 SERIAL » [ACK] (0x06) 20:32:43.424 DRIVER « [RES] [SendData] was sent: true 20:32:44.838 SERIAL « 0x010700138500008de3 (9 bytes) 20:32:44.839 SERIAL » [ACK] (0x06) 20:32:44.840 DRIVER « [REQ] [SendData] callback id: 133 transmit status: OK 20:32:44.914 SERIAL « 0x010a000400160486148602f5 (12 bytes) 20:32:44.914 SERIAL » [ACK] (0x06) 20:32:44.915 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 2 20:32:44.918 SERIAL » 0x010a00131703861386258642 (12 bytes) 20:32:44.918 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 134 └─[VersionCCCommandClassGet] CC: Version 20:32:44.918 CNTRLR [Node 022] supports CC Version (0x86) in version 2 20:32:44.919 CNTRLR » [Node 022] querying the CC version for Z-Wave Plus Info (0x5e)... 20:32:44.920 SERIAL « [ACK] (0x06) 20:32:44.924 SERIAL « 0x0104011301e8 (6 bytes) 20:32:44.924 SERIAL » [ACK] (0x06) 20:32:44.925 DRIVER « [RES] [SendData] was sent: true 20:32:46.412 SERIAL « 0x0107001386000095f8 (9 bytes) 20:32:46.412 SERIAL » [ACK] (0x06) 20:32:46.415 DRIVER « [REQ] [SendData] callback id: 134 transmit status: OK 20:32:46.491 SERIAL « 0x010a000400170486148602f4 (12 bytes) 20:32:46.492 SERIAL » [ACK] (0x06) 20:32:46.493 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 2 20:32:46.496 SERIAL » 0x010a0013180386138625874c (12 bytes) 20:32:46.496 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 135 └─[VersionCCCommandClassGet] CC: Version 20:32:46.496 CNTRLR [Node 023] supports CC Version (0x86) in version 2 20:32:46.497 CNTRLR » [Node 023] querying the CC version for Z-Wave Plus Info (0x5e)... 20:32:46.498 SERIAL « [ACK] (0x06) 20:32:46.502 SERIAL « 0x0104011301e8 (6 bytes) 20:32:46.503 SERIAL » [ACK] (0x06) 20:32:46.503 DRIVER « [RES] [SendData] was sent: true 20:32:47.942 SERIAL « 0x0110000400060a32022134000000000000c2 (18 bytes) 20:32:47.943 CNTRLR [Node 006] [Meter] value[66049]: metadata updated [Endpoint 0] 20:32:47.944 CNTRLR [Node 006] [+] [Meter] value[66049]: 0 [Endpoint 0] 20:32:47.945 CNTRLR [Node 006] [+] [Meter] deltaTime[66049]: 0 [Endpoint 0] 20:32:47.946 SERIAL » [ACK] (0x06) 20:32:47.947 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:32:48.015 SERIAL « 0x010c0004001a06310504220e6c9b (14 bytes) 20:32:48.016 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:32:48.016 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 480.7 => 369.2 [Endpoint 0] 20:32:48.017 SERIAL » [ACK] (0x06) 20:32:48.018 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 369.2 20:32:50.376 SERIAL « 0x010c0004001a06310504220e6c9b (14 bytes) 20:32:50.377 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:32:50.378 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 369.2 => 369.2 [Endpoint 0] 20:32:50.378 SERIAL » [ACK] (0x06) 20:32:50.383 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 369.2 20:32:50.500 SERIAL « 0x010c0004001a06310504220e6c9b (14 bytes) 20:32:50.501 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:32:50.501 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 369.2 => 369.2 [Endpoint 0] 20:32:50.502 SERIAL » [ACK] (0x06) 20:32:50.503 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 369.2 20:32:50.868 SERIAL « 0x010a000400180486148602fb (12 bytes) 20:32:50.869 SERIAL » [ACK] (0x06) 20:32:50.870 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 2 20:32:50.922 SERIAL « 0x01070013870001bbd6 (9 bytes) 20:32:50.922 SERIAL » [ACK] (0x06) 20:32:50.923 DRIVER « [REQ] [SendData] callback id: 135 transmit status: OK 20:32:51.812 SERIAL « 0x010c0004001c0631050422021ee3 (14 bytes) 20:32:51.813 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:32:51.813 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 65 => 54.2 [Endpoint 0] 20:32:51.814 SERIAL » [ACK] (0x06) 20:32:51.817 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 54.2 20:32:51.962 SERIAL « 0x010c0004001a06310504220e6c9b (14 bytes) 20:32:51.963 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:32:51.963 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 369.2 => 369.2 [Endpoint 0] 20:32:51.964 SERIAL » [ACK] (0x06) 20:32:51.965 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 369.2 20:32:52.057 SERIAL « 0x010c0004001a06310504220e6c9b (14 bytes) 20:32:52.058 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:32:52.059 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 369.2 => 369.2 [Endpoint 0] 20:32:52.060 SERIAL » [ACK] (0x06) 20:32:52.061 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 369.2 20:32:52.179 SERIAL « 0x010c0004001a0631050422065ca3 (14 bytes) 20:32:52.180 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:32:52.181 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 369.2 => 162.8 [Endpoint 0] 20:32:52.181 SERIAL » [ACK] (0x06) 20:32:52.182 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 162.8 20:32:52.223 SERIAL « 0x010c0004001a0631050422065ca3 (14 bytes) 20:32:52.224 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:32:52.224 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 162.8 => 162.8 [Endpoint 0] 20:32:52.225 SERIAL » [ACK] (0x06) 20:32:52.227 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 162.8 20:32:52.296 SERIAL « 0x010c0004001a0631050422065ca3 (14 bytes) 20:32:52.297 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:32:52.297 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 162.8 => 162.8 [Endpoint 0] 20:32:52.298 SERIAL » [ACK] (0x06) 20:32:52.299 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 162.8 20:32:52.526 CNTRLR [Node 024] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 20:32:53.030 SERIAL » 0x010a0013180386138625874c (12 bytes) 20:32:53.030 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 135 └─[VersionCCCommandClassGet] CC: Version 20:32:53.031 SERIAL « [ACK] (0x06) 20:32:53.035 SERIAL « 0x0104011301e8 (6 bytes) 20:32:53.036 SERIAL » [ACK] (0x06) 20:32:53.036 DRIVER « [RES] [SendData] was sent: true 20:32:54.471 SERIAL « 0x010c0004001a063105042208b140 (14 bytes) 20:32:54.472 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:32:54.473 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 162.8 => 222.5 [Endpoint 0] 20:32:54.473 SERIAL » [ACK] (0x06) 20:32:54.474 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 222.5 20:32:54.480 SERIAL « 0x0107001387000090fc (9 bytes) 20:32:54.480 SERIAL » [ACK] (0x06) 20:32:54.480 DRIVER « [REQ] [SendData] callback id: 135 transmit status: OK 20:32:54.558 SERIAL « 0x010a000400180486148602fb (12 bytes) 20:32:54.559 SERIAL » [ACK] (0x06) 20:32:54.560 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 2 20:32:54.563 SERIAL » 0x010a00131a0386135925889e (12 bytes) 20:32:54.564 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 136 └─[VersionCCCommandClassGet] CC: Association Group Information 20:32:54.564 CNTRLR [Node 024] supports CC Version (0x86) in version 2 20:32:54.564 CNTRLR » [Node 024] querying the CC version for Z-Wave Plus Info (0x5e)... 20:32:54.568 SERIAL « [ACK] (0x06) 20:32:54.573 SERIAL « 0x0104011301e8 (6 bytes) 20:32:54.573 SERIAL » [ACK] (0x06) 20:32:54.574 DRIVER « [RES] [SendData] was sent: true 20:32:54.680 SERIAL « 0x010700138800000c6f (9 bytes) 20:32:54.681 SERIAL » [ACK] (0x06) 20:32:54.681 DRIVER « [REQ] [SendData] callback id: 136 transmit status: OK 20:32:54.751 SERIAL « 0x010a0004001a048614590125 (12 bytes) 20:32:54.752 SERIAL » [ACK] (0x06) 20:32:54.752 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association Group Information version: 1 20:32:54.756 SERIAL » 0x010a00131c03861359258999 (12 bytes) 20:32:54.756 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 137 └─[VersionCCCommandClassGet] CC: Association Group Information 20:32:54.758 CNTRLR [Node 026] supports CC Association Group Information (0x59) in version 1 20:32:54.758 CNTRLR » [Node 026] querying the CC version for Configuration (0x70)... 20:32:54.761 SERIAL « [ACK] (0x06) 20:32:54.763 SERIAL « 0x0104011301e8 (6 bytes) 20:32:54.763 SERIAL » [ACK] (0x06) 20:32:54.764 DRIVER « [RES] [SendData] was sent: true 20:32:54.835 SERIAL « 0x01070013890000086a (9 bytes) 20:32:54.835 SERIAL » [ACK] (0x06) 20:32:54.836 DRIVER « [REQ] [SendData] callback id: 137 transmit status: OK 20:32:54.844 SERIAL « 0x010a0004001c048614590123 (12 bytes) 20:32:54.845 SERIAL » [ACK] (0x06) 20:32:54.846 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association Group Information version: 1 20:32:54.851 SERIAL » 0x010a00130303861372258aae (12 bytes) 20:32:54.851 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 138 └─[VersionCCCommandClassGet] CC: Manufacturer Specific 20:32:54.852 CNTRLR [Node 028] supports CC Association Group Information (0x59) in version 1 20:32:54.852 CNTRLR » [Node 028] querying the CC version for Configuration (0x70)... 20:32:54.855 SERIAL « [ACK] (0x06) 20:32:54.857 SERIAL « 0x0104011301e8 (6 bytes) 20:32:54.857 SERIAL » [ACK] (0x06) 20:32:54.858 DRIVER « [RES] [SendData] was sent: true 20:32:54.877 SERIAL « 0x010700138a00000263 (9 bytes) 20:32:54.877 SERIAL » [ACK] (0x06) 20:32:54.878 DRIVER « [REQ] [SendData] callback id: 138 transmit status: OK 20:32:54.889 SERIAL « 0x010a00040003048614720214 (12 bytes) 20:32:54.890 SERIAL » [ACK] (0x06) 20:32:54.890 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 2 20:32:54.897 SERIAL » 0x010a00130503861370258bab (12 bytes) 20:32:54.898 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 139 └─[VersionCCCommandClassGet] CC: Configuration 20:32:54.898 CNTRLR [Node 003] supports CC Manufacturer Specific (0x72) in version 2 20:32:54.899 CNTRLR » [Node 003] querying the CC version for Meter (0x32)... 20:32:54.901 SERIAL « [ACK] (0x06) 20:32:54.903 SERIAL « 0x0104011301e8 (6 bytes) 20:32:54.903 SERIAL » [ACK] (0x06) 20:32:54.904 DRIVER « [RES] [SendData] was sent: true 20:32:54.919 SERIAL « 0x010700138b00000161 (9 bytes) 20:32:54.919 SERIAL » [ACK] (0x06) 20:32:54.919 DRIVER « [REQ] [SendData] callback id: 139 transmit status: OK 20:32:54.928 SERIAL « 0x010a00040005048614700113 (12 bytes) 20:32:54.929 SERIAL » [ACK] (0x06) 20:32:54.929 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Configuration version: 1 20:32:54.930 SERIAL » 0x010a00130603861370258caf (12 bytes) 20:32:54.930 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 140 └─[VersionCCCommandClassGet] CC: Configuration 20:32:54.930 CNTRLR [Node 005] supports CC Configuration (0x70) in version 1 20:32:54.931 CNTRLR » [Node 005] querying the CC version for Meter (0x32)... 20:32:54.932 SERIAL « [ACK] (0x06) 20:32:54.936 SERIAL « 0x0104011301e8 (6 bytes) 20:32:54.936 SERIAL » [ACK] (0x06) 20:32:54.936 DRIVER « [RES] [SendData] was sent: true 20:32:54.951 SERIAL « 0x010700138c00000265 (9 bytes) 20:32:54.951 SERIAL » [ACK] (0x06) 20:32:54.952 DRIVER « [REQ] [SendData] callback id: 140 transmit status: OK 20:32:54.961 SERIAL « 0x010a00040006048614700110 (12 bytes) 20:32:54.961 SERIAL » [ACK] (0x06) 20:32:54.962 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Configuration version: 1 20:32:54.964 SERIAL » 0x010a00130203861370258daa (12 bytes) 20:32:54.964 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 141 └─[VersionCCCommandClassGet] CC: Configuration 20:32:54.964 CNTRLR [Node 006] supports CC Configuration (0x70) in version 1 20:32:54.965 CNTRLR » [Node 006] querying the CC version for Meter (0x32)... 20:32:54.966 SERIAL « [ACK] (0x06) 20:32:54.970 SERIAL « 0x0104011301e8 (6 bytes) 20:32:54.970 SERIAL » [ACK] (0x06) 20:32:54.970 DRIVER « [RES] [SendData] was sent: true 20:32:54.989 SERIAL « 0x010700138d00000264 (9 bytes) 20:32:54.990 SERIAL » [ACK] (0x06) 20:32:54.990 DRIVER « [REQ] [SendData] callback id: 141 transmit status: OK 20:32:55.017 SERIAL « 0x010a00040002048614700114 (12 bytes) 20:32:55.017 SERIAL » [ACK] (0x06) 20:32:55.018 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Configuration version: 1 20:32:55.021 SERIAL » 0x010a00131303861370258eb8 (12 bytes) 20:32:55.021 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 142 └─[VersionCCCommandClassGet] CC: Configuration 20:32:55.021 CNTRLR [Node 002] supports CC Configuration (0x70) in version 1 20:32:55.022 CNTRLR » [Node 002] querying the CC version for Notification (0x71)... 20:32:55.027 SERIAL « [ACK] (0x06) 20:32:55.029 SERIAL « 0x0104011301e8 (6 bytes) 20:32:55.029 SERIAL » [ACK] (0x06) 20:32:55.030 DRIVER « [RES] [SendData] was sent: true 20:32:55.168 SERIAL « 0x010700138e00000e6b (9 bytes) 20:32:55.169 SERIAL » [ACK] (0x06) 20:32:55.169 DRIVER « [REQ] [SendData] callback id: 142 transmit status: OK 20:32:55.295 SERIAL « 0x010a00040013048614700105 (12 bytes) 20:32:55.296 SERIAL » [ACK] (0x06) 20:32:55.296 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Configuration version: 1 20:32:55.299 SERIAL » 0x010a00131203861359258f91 (12 bytes) 20:32:55.300 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 143 └─[VersionCCCommandClassGet] CC: Association Group Information 20:32:55.300 CNTRLR [Node 019] supports CC Configuration (0x70) in version 1 20:32:55.300 CNTRLR [Node 019] skipping query for CRC-16 Encapsulation (0x56) because max implem ented version is 1 20:32:55.300 CNTRLR [Node 019] skipping query for Device Reset Locally (0x5a) because max implem ented version is 1 20:32:55.301 CNTRLR » [Node 019] querying the CC version for Firmware Update Meta Data (0x7a)... 20:32:55.303 SERIAL « [ACK] (0x06) 20:32:55.305 SERIAL « 0x0104011301e8 (6 bytes) 20:32:55.305 SERIAL » [ACK] (0x06) 20:32:55.306 DRIVER « [RES] [SendData] was sent: true 20:32:55.424 SERIAL « 0x010700138f00000c68 (9 bytes) 20:32:55.425 SERIAL » [ACK] (0x06) 20:32:55.426 DRIVER « [REQ] [SendData] callback id: 143 transmit status: OK 20:32:55.434 SERIAL « 0x010a0004001204861459012d (12 bytes) 20:32:55.435 SERIAL » [ACK] (0x06) 20:32:55.436 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association Group Information version: 1 20:32:55.440 SERIAL » 0x010a00131403861385259054 (12 bytes) 20:32:55.441 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 144 └─[VersionCCCommandClassGet] CC: Association 20:32:55.441 CNTRLR [Node 018] supports CC Association Group Information (0x59) in version 1 20:32:55.441 CNTRLR » [Node 018] querying the CC version for Notification (0x71)... 20:32:55.444 SERIAL « [ACK] (0x06) 20:32:55.446 SERIAL « 0x0104011301e8 (6 bytes) 20:32:55.447 SERIAL » [ACK] (0x06) 20:32:55.447 DRIVER « [RES] [SendData] was sent: true 20:32:55.466 SERIAL « 0x010700139000000279 (9 bytes) 20:32:55.466 SERIAL » [ACK] (0x06) 20:32:55.467 DRIVER « [REQ] [SendData] callback id: 144 transmit status: OK 20:32:55.494 SERIAL « 0x010a000400140486148502f4 (12 bytes) 20:32:55.494 SERIAL » [ACK] (0x06) 20:32:55.495 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association version: 2 20:32:55.498 SERIAL » 0x010a0013150386135e25918f (12 bytes) 20:32:55.499 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 145 └─[VersionCCCommandClassGet] CC: Z-Wave Plus Info 20:32:55.499 CNTRLR [Node 020] supports CC Association (0x85) in version 2 20:32:55.499 CNTRLR » [Node 020] querying the CC version for Association Group Information (0x59). .. 20:32:55.502 SERIAL « [ACK] (0x06) 20:32:55.504 SERIAL « 0x0104011301e8 (6 bytes) 20:32:55.505 SERIAL » [ACK] (0x06) 20:32:55.505 DRIVER « [RES] [SendData] was sent: true 20:32:56.941 SERIAL « 0x0107001391000090ea (9 bytes) 20:32:56.941 SERIAL » [ACK] (0x06) 20:32:56.942 DRIVER « [REQ] [SendData] callback id: 145 transmit status: OK 20:32:57.023 SERIAL « 0x010a000400150486145e022e (12 bytes) 20:32:57.024 SERIAL » [ACK] (0x06) 20:32:57.025 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Z-Wave Plus Info version: 2 20:32:57.027 SERIAL » 0x010a0013160386135e25928f (12 bytes) 20:32:57.028 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 146 └─[VersionCCCommandClassGet] CC: Z-Wave Plus Info 20:32:57.028 CNTRLR [Node 021] supports CC Z-Wave Plus Info (0x5e) in version 2 20:32:57.028 CNTRLR » [Node 021] querying the CC version for Association (0x85)... 20:32:57.029 SERIAL « [ACK] (0x06) 20:32:57.034 SERIAL « 0x0104011301e8 (6 bytes) 20:32:57.034 SERIAL » [ACK] (0x06) 20:32:57.034 DRIVER « [RES] [SendData] was sent: true 20:32:59.635 SERIAL « 0x01070013920001047c (9 bytes) 20:32:59.635 SERIAL » [ACK] (0x06) 20:32:59.636 DRIVER « [REQ] [SendData] callback id: 146 transmit status: OK 20:32:59.715 SERIAL « 0x010a000400160486145e022d (12 bytes) 20:32:59.716 SERIAL » [ACK] (0x06) 20:32:59.716 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Z-Wave Plus Info version: 2 20:32:59.719 SERIAL » 0x010a0013170386135e25938f (12 bytes) 20:32:59.720 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 147 └─[VersionCCCommandClassGet] CC: Z-Wave Plus Info 20:32:59.720 CNTRLR [Node 022] supports CC Z-Wave Plus Info (0x5e) in version 2 20:32:59.720 CNTRLR » [Node 022] querying the CC version for Association (0x85)... 20:32:59.723 SERIAL « [ACK] (0x06) 20:32:59.726 SERIAL « 0x0104011301e8 (6 bytes) 20:32:59.727 SERIAL » [ACK] (0x06) 20:32:59.727 DRIVER « [RES] [SendData] was sent: true 20:33:01.165 SERIAL « 0x0107001393000090e8 (9 bytes) 20:33:01.165 SERIAL » [ACK] (0x06) 20:33:01.166 DRIVER « [REQ] [SendData] callback id: 147 transmit status: OK 20:33:01.250 SERIAL « 0x010a000400170486145e022c (12 bytes) 20:33:01.251 SERIAL » [ACK] (0x06) 20:33:01.251 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Z-Wave Plus Info version: 2 20:33:01.254 SERIAL » 0x010a0013180386135e259487 (12 bytes) 20:33:01.254 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 148 └─[VersionCCCommandClassGet] CC: Z-Wave Plus Info 20:33:01.254 CNTRLR [Node 023] supports CC Z-Wave Plus Info (0x5e) in version 2 20:33:01.254 CNTRLR » [Node 023] querying the CC version for Association (0x85)... 20:33:01.256 SERIAL « [ACK] (0x06) 20:33:01.260 SERIAL « 0x0104011301e8 (6 bytes) 20:33:01.260 SERIAL » [ACK] (0x06) 20:33:01.261 DRIVER « [RES] [SendData] was sent: true 20:33:02.686 SERIAL « 0x010700139400008ff0 (9 bytes) 20:33:02.687 SERIAL » [ACK] (0x06) 20:33:02.688 DRIVER « [REQ] [SendData] callback id: 148 transmit status: OK 20:33:02.762 SERIAL « 0x010a000400180486145e0223 (12 bytes) 20:33:02.763 SERIAL » [ACK] (0x06) 20:33:02.763 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Z-Wave Plus Info version: 2 20:33:02.768 SERIAL » 0x010a00131a038613702595aa (12 bytes) 20:33:02.769 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 149 └─[VersionCCCommandClassGet] CC: Configuration 20:33:02.769 CNTRLR [Node 024] supports CC Z-Wave Plus Info (0x5e) in version 2 20:33:02.769 CNTRLR » [Node 024] querying the CC version for Association (0x85)... 20:33:02.772 SERIAL « [ACK] (0x06) 20:33:02.774 SERIAL « 0x0104011301e8 (6 bytes) 20:33:02.774 SERIAL » [ACK] (0x06) 20:33:02.775 DRIVER « [RES] [SendData] was sent: true 20:33:02.880 SERIAL « 0x010700139500000b75 (9 bytes) 20:33:02.881 SERIAL » [ACK] (0x06) 20:33:02.881 DRIVER « [REQ] [SendData] callback id: 149 transmit status: OK 20:33:02.951 SERIAL « 0x010a0004001a04861470010c (12 bytes) 20:33:02.952 SERIAL » [ACK] (0x06) 20:33:02.953 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Configuration version: 1 20:33:02.962 SERIAL » 0x010a00131c038613702596af (12 bytes) 20:33:02.963 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 150 └─[VersionCCCommandClassGet] CC: Configuration 20:33:02.964 CNTRLR [Node 026] supports CC Configuration (0x70) in version 1 20:33:02.964 CNTRLR [Node 026] skipping query for CRC-16 Encapsulation (0x56) because max implem ented version is 1 20:33:02.964 CNTRLR [Node 026] skipping query for Device Reset Locally (0x5a) because max implem ented version is 1 20:33:02.964 CNTRLR » [Node 026] querying the CC version for Firmware Update Meta Data (0x7a)... 20:33:02.967 SERIAL « [ACK] (0x06) 20:33:02.969 SERIAL « 0x0104011301e8 (6 bytes) 20:33:02.969 SERIAL » [ACK] (0x06) 20:33:02.969 DRIVER « [RES] [SendData] was sent: true 20:33:03.005 SERIAL « 0x010700139600000479 (9 bytes) 20:33:03.005 SERIAL » [ACK] (0x06) 20:33:03.006 DRIVER « [REQ] [SendData] callback id: 150 transmit status: OK 20:33:03.015 SERIAL « 0x010a0004001c04861470010a (12 bytes) 20:33:03.015 SERIAL » [ACK] (0x06) 20:33:03.016 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Configuration version: 1 20:33:03.019 SERIAL » 0x010a001303038613322597f3 (12 bytes) 20:33:03.020 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 151 └─[VersionCCCommandClassGet] CC: Meter 20:33:03.020 CNTRLR [Node 028] supports CC Configuration (0x70) in version 1 20:33:03.020 CNTRLR [Node 028] skipping query for CRC-16 Encapsulation (0x56) because max implem ented version is 1 20:33:03.020 CNTRLR [Node 028] skipping query for Device Reset Locally (0x5a) because max implem ented version is 1 20:33:03.020 CNTRLR » [Node 028] querying the CC version for Firmware Update Meta Data (0x7a)... 20:33:03.023 SERIAL « [ACK] (0x06) 20:33:03.025 SERIAL « 0x0104011301e8 (6 bytes) 20:33:03.025 SERIAL » [ACK] (0x06) 20:33:03.026 DRIVER « [RES] [SendData] was sent: true 20:33:03.045 SERIAL « 0x01070013970000027e (9 bytes) 20:33:03.045 SERIAL » [ACK] (0x06) 20:33:03.046 DRIVER « [REQ] [SendData] callback id: 151 transmit status: OK 20:33:03.056 SERIAL « 0x010a00040003048614320254 (12 bytes) 20:33:03.057 SERIAL » [ACK] (0x06) 20:33:03.058 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Meter version: 2 20:33:03.061 SERIAL » 0x010a001305038613322598fa (12 bytes) 20:33:03.061 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 152 └─[VersionCCCommandClassGet] CC: Meter 20:33:03.062 CNTRLR [Node 003] supports CC Meter (0x32) in version 2 20:33:03.062 CNTRLR » [Node 003] querying the CC version for Multi Channel Association (0x8e)... 20:33:03.064 SERIAL « [ACK] (0x06) 20:33:03.067 SERIAL « 0x0104011301e8 (6 bytes) 20:33:03.067 SERIAL » [ACK] (0x06) 20:33:03.068 DRIVER « [RES] [SendData] was sent: true 20:33:03.083 SERIAL « 0x010700139800000271 (9 bytes) 20:33:03.083 SERIAL » [ACK] (0x06) 20:33:03.084 DRIVER « [REQ] [SendData] callback id: 152 transmit status: OK 20:33:03.093 SERIAL « 0x010a00040005048614320454 (12 bytes) 20:33:03.093 SERIAL » [ACK] (0x06) 20:33:03.094 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Meter version: 4 20:33:03.097 SERIAL » 0x010a001306038613322599f8 (12 bytes) 20:33:03.097 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 153 └─[VersionCCCommandClassGet] CC: Meter 20:33:03.099 CNTRLR [Node 005] supports CC Meter (0x32) in version 4 20:33:03.099 CNTRLR » [Node 005] querying the CC version for Protection (0x75)... 20:33:03.102 SERIAL « [ACK] (0x06) 20:33:03.104 SERIAL « 0x0104011301e8 (6 bytes) 20:33:03.104 SERIAL » [ACK] (0x06) 20:33:03.105 DRIVER « [RES] [SendData] was sent: true 20:33:03.119 SERIAL « 0x010700139900000173 (9 bytes) 20:33:03.120 SERIAL » [ACK] (0x06) 20:33:03.120 DRIVER « [REQ] [SendData] callback id: 153 transmit status: OK 20:33:03.129 SERIAL « 0x010a00040006048614320457 (12 bytes) 20:33:03.130 SERIAL » [ACK] (0x06) 20:33:03.130 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Meter version: 4 20:33:03.135 SERIAL » 0x010a00130203861371259abc (12 bytes) 20:33:03.135 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 154 └─[VersionCCCommandClassGet] CC: Notification 20:33:03.135 CNTRLR [Node 006] supports CC Meter (0x32) in version 4 20:33:03.136 CNTRLR » [Node 006] querying the CC version for Protection (0x75)... 20:33:03.138 SERIAL « [ACK] (0x06) 20:33:03.141 SERIAL « 0x0104011301e8 (6 bytes) 20:33:03.141 SERIAL » [ACK] (0x06) 20:33:03.142 DRIVER « [RES] [SendData] was sent: true 20:33:03.160 SERIAL « 0x010700139a00000372 (9 bytes) 20:33:03.160 SERIAL » [ACK] (0x06) 20:33:03.161 DRIVER « [REQ] [SendData] callback id: 154 transmit status: OK 20:33:03.188 SERIAL « 0x010a00040002048614710115 (12 bytes) 20:33:03.188 SERIAL » [ACK] (0x06) 20:33:03.189 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Notification version: 1 20:33:03.192 SERIAL » 0x010a0013130386137a259ba7 (12 bytes) 20:33:03.192 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 155 └─[VersionCCCommandClassGet] CC: Firmware Update Meta Data 20:33:03.193 CNTRLR [Node 002] supports CC Notification (0x71) in version 1 20:33:03.193 CNTRLR » [Node 002] querying the CC version for Protection (0x75)... 20:33:03.196 SERIAL « [ACK] (0x06) 20:33:03.198 SERIAL « 0x0104011301e8 (6 bytes) 20:33:03.199 SERIAL » [ACK] (0x06) 20:33:03.199 DRIVER « [RES] [SendData] was sent: true 20:33:03.340 SERIAL « 0x010700139b00000e7e (9 bytes) 20:33:03.340 SERIAL » [ACK] (0x06) 20:33:03.342 DRIVER « [REQ] [SendData] callback id: 155 transmit status: OK 20:33:03.465 SERIAL « 0x010a000400130486147a030d (12 bytes) 20:33:03.465 SERIAL » [ACK] (0x06) 20:33:03.466 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Firmware Update Meta Data version: 3 20:33:03.471 SERIAL » 0x010a00131203861371259caa (12 bytes) 20:33:03.471 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 156 └─[VersionCCCommandClassGet] CC: Notification 20:33:03.472 CNTRLR [Node 019] supports CC Firmware Update Meta Data (0x7a) in version 3 20:33:03.472 CNTRLR » [Node 019] querying the CC version for Manufacturer Specific (0x72)... 20:33:03.474 SERIAL « [ACK] (0x06) 20:33:03.477 SERIAL « 0x0104011301e8 (6 bytes) 20:33:03.477 SERIAL » [ACK] (0x06) 20:33:03.478 DRIVER « [RES] [SendData] was sent: true 20:33:03.595 SERIAL « 0x010700139c00000c7b (9 bytes) 20:33:03.595 SERIAL » [ACK] (0x06) 20:33:03.596 DRIVER « [REQ] [SendData] callback id: 156 transmit status: OK 20:33:03.605 SERIAL « 0x010a00040012048614710105 (12 bytes) 20:33:03.605 SERIAL » [ACK] (0x06) 20:33:03.606 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Notification version: 1 20:33:03.609 SERIAL » 0x010a00131403861359259d85 (12 bytes) 20:33:03.610 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 157 └─[VersionCCCommandClassGet] CC: Association Group Information 20:33:03.610 CNTRLR [Node 018] supports CC Notification (0x71) in version 1 20:33:03.610 CNTRLR » [Node 018] querying the CC version for Configuration (0x70)... 20:33:03.613 SERIAL « [ACK] (0x06) 20:33:03.615 SERIAL « 0x0104011301e8 (6 bytes) 20:33:03.615 SERIAL » [ACK] (0x06) 20:33:03.616 DRIVER « [RES] [SendData] was sent: true 20:33:03.635 SERIAL « 0x010700139d00000274 (9 bytes) 20:33:03.635 SERIAL » [ACK] (0x06) 20:33:03.636 DRIVER « [REQ] [SendData] callback id: 157 transmit status: OK 20:33:03.662 SERIAL « 0x010a0004001404861459012b (12 bytes) 20:33:03.663 SERIAL » [ACK] (0x06) 20:33:03.664 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association Group Information version: 1 20:33:03.667 SERIAL » 0x010a00131503861385259e5b (12 bytes) 20:33:03.668 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 158 └─[VersionCCCommandClassGet] CC: Association 20:33:03.668 CNTRLR [Node 020] supports CC Association Group Information (0x59) in version 1 20:33:03.668 CNTRLR [Node 020] skipping query for Powerlevel (0x73) because max implemented vers ion is 0 20:33:03.668 CNTRLR » [Node 020] querying the CC version for Meter (0x32)... 20:33:03.671 SERIAL « [ACK] (0x06) 20:33:03.673 SERIAL « 0x0104011301e8 (6 bytes) 20:33:03.673 SERIAL » [ACK] (0x06) 20:33:03.674 DRIVER « [RES] [SendData] was sent: true 20:33:05.041 SERIAL « 0x010700139e000089fc (9 bytes) 20:33:05.041 SERIAL » [ACK] (0x06) 20:33:05.042 DRIVER « [REQ] [SendData] callback id: 158 transmit status: OK 20:33:05.122 SERIAL « 0x010a000400150486148502f5 (12 bytes) 20:33:05.122 SERIAL » [ACK] (0x06) 20:33:05.123 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association version: 2 20:33:05.131 SERIAL » 0x010a00131603861385259f59 (12 bytes) 20:33:05.132 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 159 └─[VersionCCCommandClassGet] CC: Association 20:33:05.132 CNTRLR [Node 021] supports CC Association (0x85) in version 2 20:33:05.132 CNTRLR » [Node 021] querying the CC version for Association Group Information (0x59). .. 20:33:05.134 SERIAL « [ACK] (0x06) 20:33:05.137 SERIAL « 0x0104011301e8 (6 bytes) 20:33:05.137 SERIAL » [ACK] (0x06) 20:33:05.137 DRIVER « [RES] [SendData] was sent: true 20:33:06.555 SERIAL « 0x010700139f00008efa (9 bytes) 20:33:06.556 SERIAL » [ACK] (0x06) 20:33:06.556 DRIVER « [REQ] [SendData] callback id: 159 transmit status: OK 20:33:06.637 SERIAL « 0x010a000400160486148502f6 (12 bytes) 20:33:06.637 SERIAL » [ACK] (0x06) 20:33:06.638 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association version: 2 20:33:06.640 SERIAL » 0x010a0013170386138525a067 (12 bytes) 20:33:06.641 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 160 └─[VersionCCCommandClassGet] CC: Association 20:33:06.641 CNTRLR [Node 022] supports CC Association (0x85) in version 2 20:33:06.641 CNTRLR » [Node 022] querying the CC version for Association Group Information (0x59). .. 20:33:06.644 SERIAL « [ACK] (0x06) 20:33:06.647 SERIAL « 0x0104011301e8 (6 bytes) 20:33:06.647 SERIAL » [ACK] (0x06) 20:33:06.648 DRIVER « [RES] [SendData] was sent: true 20:33:08.094 SERIAL « 0x01070013a0000091da (9 bytes) 20:33:08.094 SERIAL » [ACK] (0x06) 20:33:08.095 DRIVER « [REQ] [SendData] callback id: 160 transmit status: OK 20:33:08.172 SERIAL « 0x010a000400170486148502f7 (12 bytes) 20:33:08.173 SERIAL » [ACK] (0x06) 20:33:08.174 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association version: 2 20:33:08.176 SERIAL » 0x010a0013180386138525a169 (12 bytes) 20:33:08.177 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 161 └─[VersionCCCommandClassGet] CC: Association 20:33:08.177 CNTRLR [Node 023] supports CC Association (0x85) in version 2 20:33:08.177 CNTRLR » [Node 023] querying the CC version for Association Group Information (0x59). .. 20:33:08.180 SERIAL « [ACK] (0x06) 20:33:08.183 SERIAL « 0x0104011301e8 (6 bytes) 20:33:08.183 SERIAL » [ACK] (0x06) 20:33:08.183 DRIVER « [RES] [SendData] was sent: true 20:33:09.616 SERIAL « 0x01070013a1000090da (9 bytes) 20:33:09.616 SERIAL » [ACK] (0x06) 20:33:09.617 DRIVER « [REQ] [SendData] callback id: 161 transmit status: OK 20:33:09.698 SERIAL « 0x010a000400180486148502f8 (12 bytes) 20:33:09.699 SERIAL » [ACK] (0x06) 20:33:09.700 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association version: 2 20:33:09.703 SERIAL » 0x010a00131a0386137a25a297 (12 bytes) 20:33:09.703 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 162 └─[VersionCCCommandClassGet] CC: Firmware Update Meta Data 20:33:09.703 CNTRLR [Node 024] supports CC Association (0x85) in version 2 20:33:09.704 CNTRLR » [Node 024] querying the CC version for Association Group Information (0x59). .. 20:33:09.705 SERIAL « [ACK] (0x06) 20:33:09.720 SERIAL « 0x0104011301e8 (6 bytes) 20:33:09.720 SERIAL » [ACK] (0x06) 20:33:09.720 DRIVER « [RES] [SendData] was sent: true 20:33:09.810 SERIAL « 0x01070013a200000a43 (9 bytes) 20:33:09.811 SERIAL » [ACK] (0x06) 20:33:09.812 DRIVER « [REQ] [SendData] callback id: 162 transmit status: OK 20:33:09.881 SERIAL « 0x010a0004001a0486147a0304 (12 bytes) 20:33:09.881 SERIAL » [ACK] (0x06) 20:33:09.882 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Firmware Update Meta Data version: 3 20:33:09.886 SERIAL » 0x010a00131c0386137a25a390 (12 bytes) 20:33:09.886 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 163 └─[VersionCCCommandClassGet] CC: Firmware Update Meta Data 20:33:09.886 CNTRLR [Node 026] supports CC Firmware Update Meta Data (0x7a) in version 3 20:33:09.887 CNTRLR » [Node 026] querying the CC version for Manufacturer Specific (0x72)... 20:33:09.889 SERIAL « [ACK] (0x06) 20:33:09.891 SERIAL « 0x0104011301e8 (6 bytes) 20:33:09.892 SERIAL » [ACK] (0x06) 20:33:09.892 DRIVER « [RES] [SendData] was sent: true 20:33:09.964 SERIAL « 0x01070013a300000840 (9 bytes) 20:33:09.964 SERIAL » [ACK] (0x06) 20:33:09.965 DRIVER « [REQ] [SendData] callback id: 163 transmit status: OK 20:33:09.974 SERIAL « 0x010a0004001c0486147a0302 (12 bytes) 20:33:09.975 SERIAL » [ACK] (0x06) 20:33:09.975 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Firmware Update Meta Data version: 3 20:33:09.978 SERIAL » 0x010a0013030386138e25a47c (12 bytes) 20:33:09.979 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 164 └─[VersionCCCommandClassGet] CC: Multi Channel Association 20:33:09.979 CNTRLR [Node 028] supports CC Firmware Update Meta Data (0x7a) in version 3 20:33:09.979 CNTRLR » [Node 028] querying the CC version for Manufacturer Specific (0x72)... 20:33:09.982 SERIAL « [ACK] (0x06) 20:33:09.984 SERIAL « 0x0104011301e8 (6 bytes) 20:33:09.985 SERIAL » [ACK] (0x06) 20:33:09.985 DRIVER « [RES] [SendData] was sent: true 20:33:10.004 SERIAL « 0x01070013a40000024d (9 bytes) 20:33:10.004 SERIAL » [ACK] (0x06) 20:33:10.008 DRIVER « [REQ] [SendData] callback id: 164 transmit status: OK 20:33:10.016 SERIAL « 0x010a000400030486148e03e9 (12 bytes) 20:33:10.016 SERIAL » [ACK] (0x06) 20:33:10.017 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multi Channel Association version: 3 20:33:10.023 SERIAL » 0x010a0013050386137525a580 (12 bytes) 20:33:10.024 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 165 └─[VersionCCCommandClassGet] CC: Protection 20:33:10.024 CNTRLR [Node 003] supports CC Multi Channel Association (0x8e) in version 3 20:33:10.024 CNTRLR » [Node 003] querying the CC version for Notification (0x71)... 20:33:10.027 SERIAL « [ACK] (0x06) 20:33:10.029 SERIAL « 0x0104011301e8 (6 bytes) 20:33:10.029 SERIAL » [ACK] (0x06) 20:33:10.030 DRIVER « [RES] [SendData] was sent: true 20:33:10.045 SERIAL « 0x01070013a50000024c (9 bytes) 20:33:10.045 SERIAL » [ACK] (0x06) 20:33:10.046 DRIVER « [REQ] [SendData] callback id: 165 transmit status: OK 20:33:10.055 SERIAL « 0x010a00040005048614750215 (12 bytes) 20:33:10.055 SERIAL » [ACK] (0x06) 20:33:10.056 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Protection version: 2 20:33:10.059 SERIAL » 0x010a0013060386137525a680 (12 bytes) 20:33:10.060 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 166 └─[VersionCCCommandClassGet] CC: Protection 20:33:10.060 CNTRLR [Node 005] supports CC Protection (0x75) in version 2 20:33:10.060 CNTRLR [Node 005] skipping query for Scene Actuator Configuration (0x2c) because ma x implemented version is 0 20:33:10.060 CNTRLR [Node 005] skipping query for Scene Activation (0x2b) because max implemente d version is 1 20:33:10.061 CNTRLR » [Node 005] querying the CC version for Firmware Update Meta Data (0x7a)... 20:33:10.065 SERIAL « [ACK] (0x06) 20:33:10.066 SERIAL « 0x0104011301e8 (6 bytes) 20:33:10.067 SERIAL » [ACK] (0x06) 20:33:10.067 DRIVER « [RES] [SendData] was sent: true 20:33:10.080 SERIAL « 0x01070013a60000024f (9 bytes) 20:33:10.081 SERIAL » [ACK] (0x06) 20:33:10.081 DRIVER « [REQ] [SendData] callback id: 166 transmit status: OK 20:33:10.090 SERIAL « 0x010a00040006048614750216 (12 bytes) 20:33:10.091 SERIAL » [ACK] (0x06) 20:33:10.091 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Protection version: 2 20:33:10.094 SERIAL » 0x010a0013020386137525a785 (12 bytes) 20:33:10.095 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 167 └─[VersionCCCommandClassGet] CC: Protection 20:33:10.096 CNTRLR [Node 006] supports CC Protection (0x75) in version 2 20:33:10.096 CNTRLR [Node 006] skipping query for Scene Actuator Configuration (0x2c) because ma x implemented version is 0 20:33:10.096 CNTRLR [Node 006] skipping query for Scene Activation (0x2b) because max implemente d version is 1 20:33:10.096 CNTRLR » [Node 006] querying the CC version for Firmware Update Meta Data (0x7a)... 20:33:10.099 SERIAL « [ACK] (0x06) 20:33:10.101 SERIAL « 0x0104011301e8 (6 bytes) 20:33:10.101 SERIAL » [ACK] (0x06) 20:33:10.102 DRIVER « [RES] [SendData] was sent: true 20:33:10.121 SERIAL « 0x01070013a70000034f (9 bytes) 20:33:10.121 SERIAL » [ACK] (0x06) 20:33:10.122 DRIVER « [REQ] [SendData] callback id: 167 transmit status: OK 20:33:10.148 SERIAL « 0x010a00040002048614750212 (12 bytes) 20:33:10.149 SERIAL » [ACK] (0x06) 20:33:10.149 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Protection version: 2 20:33:10.153 SERIAL » 0x010a0013130386137225a89c (12 bytes) 20:33:10.154 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 168 └─[VersionCCCommandClassGet] CC: Manufacturer Specific 20:33:10.154 CNTRLR [Node 002] supports CC Protection (0x75) in version 2 20:33:10.155 CNTRLR » [Node 002] querying the CC version for Firmware Update Meta Data (0x7a)... 20:33:10.157 SERIAL « [ACK] (0x06) 20:33:10.159 SERIAL « 0x0104011301e8 (6 bytes) 20:33:10.160 SERIAL » [ACK] (0x06) 20:33:10.160 DRIVER « [RES] [SendData] was sent: true 20:33:10.301 SERIAL « 0x01070013a800000f4c (9 bytes) 20:33:10.302 SERIAL » [ACK] (0x06) 20:33:10.302 DRIVER « [REQ] [SendData] callback id: 168 transmit status: OK 20:33:10.425 SERIAL « 0x010a00040013048614720204 (12 bytes) 20:33:10.426 SERIAL » [ACK] (0x06) 20:33:10.426 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 2 20:33:10.430 SERIAL » 0x010a0013120386137025a99e (12 bytes) 20:33:10.430 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 169 └─[VersionCCCommandClassGet] CC: Configuration 20:33:10.430 CNTRLR [Node 019] supports CC Manufacturer Specific (0x72) in version 2 20:33:10.431 CNTRLR » [Node 019] querying the CC version for Meter (0x32)... 20:33:10.434 SERIAL « [ACK] (0x06) 20:33:10.435 SERIAL « 0x0104011301e8 (6 bytes) 20:33:10.436 SERIAL » [ACK] (0x06) 20:33:10.436 DRIVER « [RES] [SendData] was sent: true 20:33:10.554 SERIAL « 0x01070013a900000c4e (9 bytes) 20:33:10.555 SERIAL » [ACK] (0x06) 20:33:10.555 DRIVER « [REQ] [SendData] callback id: 169 transmit status: OK 20:33:10.564 SERIAL « 0x010a00040012048614700104 (12 bytes) 20:33:10.565 SERIAL » [ACK] (0x06) 20:33:10.565 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Configuration version: 1 20:33:10.569 SERIAL » 0x010a0013140386133225aad9 (12 bytes) 20:33:10.570 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 170 └─[VersionCCCommandClassGet] CC: Meter 20:33:10.570 CNTRLR [Node 018] supports CC Configuration (0x70) in version 1 20:33:10.570 CNTRLR » [Node 018] querying the CC version for Meter (0x32)... 20:33:10.573 SERIAL « [ACK] (0x06) 20:33:10.575 SERIAL « 0x0104011301e8 (6 bytes) 20:33:10.575 SERIAL » [ACK] (0x06) 20:33:10.576 DRIVER « [RES] [SendData] was sent: true 20:33:10.595 SERIAL « 0x01070013aa00000243 (9 bytes) 20:33:10.595 SERIAL » [ACK] (0x06) 20:33:10.596 DRIVER « [REQ] [SendData] callback id: 170 transmit status: OK 20:33:10.621 SERIAL « 0x010a00040014048614320342 (12 bytes) 20:33:10.622 SERIAL » [ACK] (0x06) 20:33:10.622 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Meter version: 3 20:33:10.625 SERIAL » 0x010a0013150386135925abb2 (12 bytes) 20:33:10.626 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 171 └─[VersionCCCommandClassGet] CC: Association Group Information 20:33:10.626 CNTRLR [Node 020] supports CC Meter (0x32) in version 3 20:33:10.626 CNTRLR » [Node 020] querying the CC version for Configuration (0x70)... 20:33:10.629 SERIAL « [ACK] (0x06) 20:33:10.631 SERIAL « 0x0104011301e8 (6 bytes) 20:33:10.632 SERIAL » [ACK] (0x06) 20:33:10.632 DRIVER « [RES] [SendData] was sent: true 20:33:11.963 SERIAL « 0x01070013ab000086c6 (9 bytes) 20:33:11.964 SERIAL » [ACK] (0x06) 20:33:11.964 DRIVER « [REQ] [SendData] callback id: 171 transmit status: OK 20:33:12.041 SERIAL « 0x010a0004001504861459012a (12 bytes) 20:33:12.041 SERIAL » [ACK] (0x06) 20:33:12.042 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association Group Information version: 1 20:33:12.045 SERIAL » 0x010a0013160386135925acb6 (12 bytes) 20:33:12.045 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 172 └─[VersionCCCommandClassGet] CC: Association Group Information 20:33:12.046 CNTRLR [Node 021] supports CC Association Group Information (0x59) in version 1 20:33:12.046 CNTRLR [Node 021] skipping query for Device Reset Locally (0x5a) because max implem ented version is 1 20:33:12.046 CNTRLR » [Node 021] querying the CC version for Protection (0x75)... 20:33:12.048 SERIAL « [ACK] (0x06) 20:33:12.051 SERIAL « 0x0104011301e8 (6 bytes) 20:33:12.051 SERIAL » [ACK] (0x06) 20:33:12.051 DRIVER « [RES] [SendData] was sent: true 20:33:13.491 SERIAL « 0x010c0004001c063105042202ee13 (14 bytes) 20:33:13.492 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:33:13.493 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 54.2 => 75 [Endpoint 0] 20:33:13.494 SERIAL » [ACK] (0x06) 20:33:13.494 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 75 20:33:13.514 SERIAL « 0x01070013ac000093d4 (9 bytes) 20:33:13.515 SERIAL » [ACK] (0x06) 20:33:13.515 DRIVER « [REQ] [SendData] callback id: 172 transmit status: OK 20:33:13.599 SERIAL « 0x010a00040016048614590129 (12 bytes) 20:33:13.600 SERIAL » [ACK] (0x06) 20:33:13.603 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association Group Information version: 1 20:33:13.606 SERIAL » 0x010a0013170386135925adb6 (12 bytes) 20:33:13.606 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 173 └─[VersionCCCommandClassGet] CC: Association Group Information 20:33:13.607 CNTRLR [Node 022] supports CC Association Group Information (0x59) in version 1 20:33:13.607 CNTRLR [Node 022] skipping query for Device Reset Locally (0x5a) because max implem ented version is 1 20:33:13.607 CNTRLR » [Node 022] querying the CC version for Protection (0x75)... 20:33:13.609 SERIAL « [ACK] (0x06) 20:33:13.611 SERIAL « 0x0104011301e8 (6 bytes) 20:33:13.612 SERIAL » [ACK] (0x06) 20:33:13.612 DRIVER « [RES] [SendData] was sent: true 20:33:13.812 SERIAL « 0x010c0004001c063105042203619d (14 bytes) 20:33:13.813 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:33:13.813 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 75 => 86.5 [Endpoint 0] 20:33:13.814 SERIAL » [ACK] (0x06) 20:33:13.815 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 86.5 20:33:13.843 SERIAL « 0x010c0004001c063105042203619d (14 bytes) 20:33:13.844 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:33:13.844 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 86.5 => 86.5 [Endpoint 0] 20:33:13.845 SERIAL » [ACK] (0x06) 20:33:13.846 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 86.5 20:33:15.229 SERIAL « 0x01070013ad0000a2e4 (9 bytes) 20:33:15.229 SERIAL » [ACK] (0x06) 20:33:15.230 DRIVER « [REQ] [SendData] callback id: 173 transmit status: OK 20:33:15.305 SERIAL « 0x010a00040017048614590128 (12 bytes) 20:33:15.306 SERIAL » [ACK] (0x06) 20:33:15.306 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association Group Information version: 1 20:33:15.309 SERIAL » 0x010a0013180386135925aeba (12 bytes) 20:33:15.309 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 174 └─[VersionCCCommandClassGet] CC: Association Group Information 20:33:15.310 CNTRLR [Node 023] supports CC Association Group Information (0x59) in version 1 20:33:15.310 CNTRLR [Node 023] skipping query for Device Reset Locally (0x5a) because max implem ented version is 1 20:33:15.310 CNTRLR » [Node 023] querying the CC version for Protection (0x75)... 20:33:15.311 SERIAL « [ACK] (0x06) 20:33:15.315 SERIAL « 0x0104011301e8 (6 bytes) 20:33:15.315 SERIAL » [ACK] (0x06) 20:33:15.316 DRIVER « [RES] [SendData] was sent: true 20:33:16.747 SERIAL « 0x01070013ae00008fca (9 bytes) 20:33:16.747 SERIAL » [ACK] (0x06) 20:33:16.748 DRIVER « [REQ] [SendData] callback id: 174 transmit status: OK 20:33:16.823 SERIAL « 0x010a00040018048614590127 (12 bytes) 20:33:16.824 SERIAL » [ACK] (0x06) 20:33:16.825 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association Group Information version: 1 20:33:16.828 SERIAL » 0x010a00131a0386137225af92 (12 bytes) 20:33:16.828 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 175 └─[VersionCCCommandClassGet] CC: Manufacturer Specific 20:33:16.828 CNTRLR [Node 024] supports CC Association Group Information (0x59) in version 1 20:33:16.828 CNTRLR [Node 024] skipping query for Device Reset Locally (0x5a) because max implem ented version is 1 20:33:16.829 CNTRLR » [Node 024] querying the CC version for Protection (0x75)... 20:33:16.831 SERIAL « [ACK] (0x06) 20:33:16.834 SERIAL « 0x0104011301e8 (6 bytes) 20:33:16.834 SERIAL » [ACK] (0x06) 20:33:16.835 DRIVER « [RES] [SendData] was sent: true 20:33:16.940 SERIAL « 0x01070013af00000a4e (9 bytes) 20:33:16.940 SERIAL » [ACK] (0x06) 20:33:16.941 DRIVER « [REQ] [SendData] callback id: 175 transmit status: OK 20:33:17.011 SERIAL « 0x010a0004001a04861472020d (12 bytes) 20:33:17.011 SERIAL » [ACK] (0x06) 20:33:17.015 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 2 20:33:17.021 SERIAL » 0x010a00131c0386137225b08b (12 bytes) 20:33:17.021 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 176 └─[VersionCCCommandClassGet] CC: Manufacturer Specific 20:33:17.022 CNTRLR [Node 026] supports CC Manufacturer Specific (0x72) in version 2 20:33:17.022 CNTRLR » [Node 026] querying the CC version for Meter (0x32)... 20:33:17.028 SERIAL « [ACK] (0x06) 20:33:17.029 SERIAL « 0x0104011301e8 (6 bytes) 20:33:17.029 SERIAL » [ACK] (0x06) 20:33:17.030 DRIVER « [RES] [SendData] was sent: true 20:33:17.094 SERIAL « 0x01070013b00000075c (9 bytes) 20:33:17.094 SERIAL » [ACK] (0x06) 20:33:17.095 DRIVER « [REQ] [SendData] callback id: 176 transmit status: OK 20:33:17.104 SERIAL « 0x010a0004001c04861472020b (12 bytes) 20:33:17.104 SERIAL » [ACK] (0x06) 20:33:17.105 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 2 20:33:17.107 SERIAL » 0x010a0013030386137125b196 (12 bytes) 20:33:17.107 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 177 └─[VersionCCCommandClassGet] CC: Notification 20:33:17.107 CNTRLR [Node 028] supports CC Manufacturer Specific (0x72) in version 2 20:33:17.107 CNTRLR » [Node 028] querying the CC version for Meter (0x32)... 20:33:17.109 SERIAL « [ACK] (0x06) 20:33:17.112 SERIAL « 0x0104011301e8 (6 bytes) 20:33:17.112 SERIAL » [ACK] (0x06) 20:33:17.113 DRIVER « [RES] [SendData] was sent: true 20:33:17.132 SERIAL « 0x01070013b100000359 (9 bytes) 20:33:17.132 SERIAL » [ACK] (0x06) 20:33:17.133 DRIVER « [REQ] [SendData] callback id: 177 transmit status: OK 20:33:17.144 SERIAL « 0x010a00040003048614710510 (12 bytes) 20:33:17.145 SERIAL » [ACK] (0x06) 20:33:17.145 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Notification version: 5 20:33:17.148 SERIAL » 0x010a0013050386137a25b298 (12 bytes) 20:33:17.148 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 178 └─[VersionCCCommandClassGet] CC: Firmware Update Meta Data 20:33:17.149 CNTRLR [Node 003] supports CC Notification (0x71) in version 5 20:33:17.149 CNTRLR [Node 003] skipping query for Powerlevel (0x73) because max implemented vers ion is 0 20:33:17.149 CNTRLR [Node 003] skipping query for Security (0x98) because max implemented versio n is 1 20:33:17.149 CNTRLR » [Node 003] querying the CC version for Multilevel Sensor (0x31)... 20:33:17.152 SERIAL « [ACK] (0x06) 20:33:17.154 SERIAL « 0x0104011301e8 (6 bytes) 20:33:17.154 SERIAL » [ACK] (0x06) 20:33:17.155 DRIVER « [RES] [SendData] was sent: true 20:33:17.169 SERIAL « 0x01070013b200000158 (9 bytes) 20:33:17.170 SERIAL » [ACK] (0x06) 20:33:17.170 DRIVER « [REQ] [SendData] callback id: 178 transmit status: OK 20:33:17.179 SERIAL « 0x010a000400050486147a021a (12 bytes) 20:33:17.180 SERIAL » [ACK] (0x06) 20:33:17.180 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Firmware Update Meta Data version: 2 20:33:17.185 SERIAL » 0x010a0013060386137a25b39a (12 bytes) 20:33:17.186 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 179 └─[VersionCCCommandClassGet] CC: Firmware Update Meta Data 20:33:17.186 CNTRLR [Node 005] supports CC Firmware Update Meta Data (0x7a) in version 2 20:33:17.187 CNTRLR [Node 005] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 20:33:17.187 CNTRLR [Node 005] trying to load device config 20:33:17.195 SERIAL « [ACK] (0x06) 20:33:17.196 SERIAL « 0x0104011301e8 (6 bytes) 20:33:17.196 SERIAL » [ACK] (0x06) 20:33:17.197 DRIVER « [RES] [SendData] was sent: true 20:33:17.206 CNTRLR [Node 005] device config loaded 20:33:17.208 SERIAL « 0x01070013b30000025a (9 bytes) 20:33:17.208 SERIAL » [ACK] (0x06) 20:33:17.209 DRIVER « [REQ] [SendData] callback id: 179 transmit status: OK 20:33:17.210 CNTRLR [Node 005] ZWavePlusCC: doing a complete interview... 20:33:17.211 CNTRLR » [Node 005] querying Z-Wave+ information... 20:33:17.217 SERIAL « 0x010a000400060486147a0219 (12 bytes) 20:33:17.217 SERIAL » [ACK] (0x06) 20:33:17.217 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Firmware Update Meta Data version: 2 20:33:17.218 SERIAL » 0x010a0013020386137a25b499 (12 bytes) 20:33:17.218 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 180 └─[VersionCCCommandClassGet] CC: Firmware Update Meta Data 20:33:17.219 CNTRLR [Node 006] supports CC Firmware Update Meta Data (0x7a) in version 2 20:33:17.219 CNTRLR [Node 006] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 20:33:17.219 CNTRLR [Node 006] trying to load device config 20:33:17.220 SERIAL « [ACK] (0x06) 20:33:17.222 CNTRLR [Node 006] device config loaded 20:33:17.222 CNTRLR [Node 006] ZWavePlusCC: doing a complete interview... 20:33:17.222 CNTRLR » [Node 006] querying Z-Wave+ information... 20:33:17.224 SERIAL « 0x0104011301e8 (6 bytes) 20:33:17.224 SERIAL » [ACK] (0x06) 20:33:17.224 DRIVER « [RES] [SendData] was sent: true 20:33:17.258 SERIAL « 0x01070013b40000035c (9 bytes) 20:33:17.259 SERIAL » [ACK] (0x06) 20:33:17.259 DRIVER « [REQ] [SendData] callback id: 180 transmit status: OK 20:33:17.287 SERIAL « 0x010a000400020486147a021d (12 bytes) 20:33:17.288 SERIAL » [ACK] (0x06) 20:33:17.291 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Firmware Update Meta Data version: 2 20:33:17.294 SERIAL » 0x010a0013130386133225b5c1 (12 bytes) 20:33:17.295 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 181 └─[VersionCCCommandClassGet] CC: Meter 20:33:17.295 CNTRLR [Node 002] supports CC Firmware Update Meta Data (0x7a) in version 2 20:33:17.295 CNTRLR [Node 002] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 20:33:17.296 CNTRLR [Node 002] trying to load device config 20:33:17.303 SERIAL « [ACK] (0x06) 20:33:17.304 SERIAL « 0x0104011301e8 (6 bytes) 20:33:17.305 SERIAL » [ACK] (0x06) 20:33:17.305 DRIVER « [RES] [SendData] was sent: true 20:33:17.311 CNTRLR [Node 002] device config loaded 20:33:17.311 CNTRLR [Node 002] ZWavePlusCC: doing a complete interview... 20:33:17.312 CNTRLR » [Node 002] querying Z-Wave+ information... 20:33:17.441 SERIAL « 0x01070013b500000f51 (9 bytes) 20:33:17.442 SERIAL » [ACK] (0x06) 20:33:17.442 DRIVER « [REQ] [SendData] callback id: 181 transmit status: OK 20:33:17.565 SERIAL « 0x010a00040013048614320244 (12 bytes) 20:33:17.565 SERIAL » [ACK] (0x06) 20:33:17.566 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Meter version: 2 20:33:17.569 SERIAL » 0x010a0013120386133225b6c3 (12 bytes) 20:33:17.569 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 182 └─[VersionCCCommandClassGet] CC: Meter 20:33:17.569 CNTRLR [Node 019] supports CC Meter (0x32) in version 2 20:33:17.570 CNTRLR » [Node 019] querying the CC version for Multi Channel Association (0x8e)... 20:33:17.571 SERIAL « [ACK] (0x06) 20:33:17.574 SERIAL « 0x0104011301e8 (6 bytes) 20:33:17.575 SERIAL » [ACK] (0x06) 20:33:17.575 DRIVER « [RES] [SendData] was sent: true 20:33:17.694 SERIAL « 0x01070013b600000c51 (9 bytes) 20:33:17.695 SERIAL » [ACK] (0x06) 20:33:17.695 DRIVER « [REQ] [SendData] callback id: 182 transmit status: OK 20:33:17.704 SERIAL « 0x010a00040012048614320443 (12 bytes) 20:33:17.705 SERIAL » [ACK] (0x06) 20:33:17.706 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Meter version: 4 20:33:17.709 SERIAL » 0x010a0013140386137025b786 (12 bytes) 20:33:17.709 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 183 └─[VersionCCCommandClassGet] CC: Configuration 20:33:17.709 CNTRLR [Node 018] supports CC Meter (0x32) in version 4 20:33:17.710 CNTRLR » [Node 018] querying the CC version for Protection (0x75)... 20:33:17.712 SERIAL « [ACK] (0x06) 20:33:17.714 SERIAL « 0x0104011301e8 (6 bytes) 20:33:17.715 SERIAL » [ACK] (0x06) 20:33:17.715 DRIVER « [RES] [SendData] was sent: true 20:33:17.734 SERIAL « 0x01070013b70000025e (9 bytes) 20:33:17.734 SERIAL » [ACK] (0x06) 20:33:17.735 DRIVER « [REQ] [SendData] callback id: 183 transmit status: OK 20:33:17.761 SERIAL « 0x010a00040014048614700102 (12 bytes) 20:33:17.762 SERIAL » [ACK] (0x06) 20:33:17.763 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Configuration version: 1 20:33:17.768 SERIAL » 0x010a0013150386137525b88d (12 bytes) 20:33:17.768 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 184 └─[VersionCCCommandClassGet] CC: Protection 20:33:17.769 CNTRLR [Node 020] supports CC Configuration (0x70) in version 1 20:33:17.769 CNTRLR » [Node 020] querying the CC version for Notification (0x71)... 20:33:17.771 SERIAL « [ACK] (0x06) 20:33:17.774 SERIAL « 0x0104011301e8 (6 bytes) 20:33:17.774 SERIAL » [ACK] (0x06) 20:33:17.775 DRIVER « [RES] [SendData] was sent: true 20:33:17.812 SERIAL « 0x010a00040014048614700102 (12 bytes) 20:33:17.812 SERIAL » [ACK] (0x06) 20:33:17.813 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Configuration version: 1 20:33:19.302 SERIAL « 0x01070013b8000099ca (9 bytes) 20:33:19.303 SERIAL » [ACK] (0x06) 20:33:19.303 DRIVER « [REQ] [SendData] callback id: 184 transmit status: OK 20:33:19.387 SERIAL « 0x010a00040015048614750106 (12 bytes) 20:33:19.387 SERIAL » [ACK] (0x06) 20:33:19.388 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Protection version: 1 20:33:19.391 SERIAL » 0x010a0013160386137525b98f (12 bytes) 20:33:19.391 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 185 └─[VersionCCCommandClassGet] CC: Protection 20:33:19.391 CNTRLR [Node 021] supports CC Protection (0x75) in version 1 20:33:19.392 CNTRLR » [Node 021] querying the CC version for Multilevel Sensor (0x31)... 20:33:19.393 SERIAL « [ACK] (0x06) 20:33:19.397 SERIAL « 0x0104011301e8 (6 bytes) 20:33:19.397 SERIAL » [ACK] (0x06) 20:33:19.398 DRIVER « [RES] [SendData] was sent: true 20:33:20.808 SERIAL « 0x01070013b900008ddf (9 bytes) 20:33:20.809 SERIAL » [ACK] (0x06) 20:33:20.809 DRIVER « [REQ] [SendData] callback id: 185 transmit status: OK 20:33:20.886 SERIAL « 0x010a00040016048614750105 (12 bytes) 20:33:20.886 SERIAL » [ACK] (0x06) 20:33:20.887 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Protection version: 1 20:33:20.890 SERIAL » 0x010a0013170386137525ba8d (12 bytes) 20:33:20.890 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 186 └─[VersionCCCommandClassGet] CC: Protection 20:33:20.891 CNTRLR [Node 022] supports CC Protection (0x75) in version 1 20:33:20.891 CNTRLR » [Node 022] querying the CC version for Multilevel Sensor (0x31)... 20:33:20.893 SERIAL « [ACK] (0x06) 20:33:20.897 SERIAL « 0x0104011301e8 (6 bytes) 20:33:20.897 SERIAL » [ACK] (0x06) 20:33:20.897 DRIVER « [RES] [SendData] was sent: true 20:33:22.333 SERIAL « 0x01070013ba000090c1 (9 bytes) 20:33:22.333 SERIAL » [ACK] (0x06) 20:33:22.334 DRIVER « [REQ] [SendData] callback id: 186 transmit status: OK 20:33:22.443 SERIAL « 0x010a00040017048614750104 (12 bytes) 20:33:22.443 SERIAL » [ACK] (0x06) 20:33:22.444 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Protection version: 1 20:33:22.447 SERIAL » 0x010a0013180386137525bb83 (12 bytes) 20:33:22.447 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 187 └─[VersionCCCommandClassGet] CC: Protection 20:33:22.448 CNTRLR [Node 023] supports CC Protection (0x75) in version 1 20:33:22.448 CNTRLR » [Node 023] querying the CC version for Multilevel Sensor (0x31)... 20:33:22.449 SERIAL « [ACK] (0x06) 20:33:22.453 SERIAL « 0x0104011301e8 (6 bytes) 20:33:22.454 SERIAL » [ACK] (0x06) 20:33:22.454 DRIVER « [RES] [SendData] was sent: true 20:33:23.956 SERIAL « 0x01070013bb000096c6 (9 bytes) 20:33:23.956 SERIAL » [ACK] (0x06) 20:33:23.957 DRIVER « [REQ] [SendData] callback id: 187 transmit status: OK 20:33:24.041 SERIAL « 0x010a0004001804861475010b (12 bytes) 20:33:24.042 SERIAL » [ACK] (0x06) 20:33:24.043 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Protection version: 1 20:33:24.046 SERIAL » 0x010a00131a0386133225bcc1 (12 bytes) 20:33:24.046 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 188 └─[VersionCCCommandClassGet] CC: Meter 20:33:24.046 CNTRLR [Node 024] supports CC Protection (0x75) in version 1 20:33:24.046 CNTRLR » [Node 024] querying the CC version for Multilevel Sensor (0x31)... 20:33:24.048 SERIAL « [ACK] (0x06) 20:33:24.052 SERIAL « 0x0104011301e8 (6 bytes) 20:33:24.052 SERIAL » [ACK] (0x06) 20:33:24.052 DRIVER « [RES] [SendData] was sent: true 20:33:24.150 SERIAL « 0x01070013bc00000a5d (9 bytes) 20:33:24.151 SERIAL » [ACK] (0x06) 20:33:24.151 DRIVER « [REQ] [SendData] callback id: 188 transmit status: OK 20:33:24.221 SERIAL « 0x010a0004001a04861432024d (12 bytes) 20:33:24.221 SERIAL » [ACK] (0x06) 20:33:24.222 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Meter version: 2 20:33:24.232 SERIAL » 0x010a00131c0386133225bdc6 (12 bytes) 20:33:24.232 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 189 └─[VersionCCCommandClassGet] CC: Meter 20:33:24.233 CNTRLR [Node 026] supports CC Meter (0x32) in version 2 20:33:24.233 CNTRLR » [Node 026] querying the CC version for Multi Channel Association (0x8e)... 20:33:24.235 SERIAL « [ACK] (0x06) 20:33:24.238 SERIAL « 0x0104011301e8 (6 bytes) 20:33:24.238 SERIAL » [ACK] (0x06) 20:33:24.238 DRIVER « [RES] [SendData] was sent: true 20:33:24.305 SERIAL « 0x01070013bd00000751 (9 bytes) 20:33:24.306 SERIAL » [ACK] (0x06) 20:33:24.306 DRIVER « [REQ] [SendData] callback id: 189 transmit status: OK 20:33:24.314 SERIAL « 0x010a0004001c04861432024b (12 bytes) 20:33:24.315 SERIAL » [ACK] (0x06) 20:33:24.316 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Meter version: 2 20:33:24.319 SERIAL » 0x010a0013030386133125bed9 (12 bytes) 20:33:24.319 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 190 └─[VersionCCCommandClassGet] CC: Multilevel Sensor 20:33:24.320 CNTRLR [Node 028] supports CC Meter (0x32) in version 2 20:33:24.320 CNTRLR » [Node 028] querying the CC version for Multi Channel Association (0x8e)... 20:33:24.322 SERIAL « [ACK] (0x06) 20:33:24.325 SERIAL « 0x0104011301e8 (6 bytes) 20:33:24.325 SERIAL » [ACK] (0x06) 20:33:24.325 DRIVER « [RES] [SendData] was sent: true 20:33:24.344 SERIAL « 0x01070013be00000257 (9 bytes) 20:33:24.345 SERIAL » [ACK] (0x06) 20:33:24.348 DRIVER « [REQ] [SendData] callback id: 190 transmit status: OK 20:33:24.356 SERIAL « 0x010a00040003048614310550 (12 bytes) 20:33:24.357 SERIAL » [ACK] (0x06) 20:33:24.358 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multilevel Sensor version: 5 20:33:24.362 SERIAL » 0x0109001305025e0125bf27 (11 bytes) 20:33:24.362 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 191 └─[ZWavePlusCCGet] 20:33:24.363 CNTRLR [Node 003] supports CC Multilevel Sensor (0x31) in version 5 20:33:24.363 CNTRLR » [Node 003] querying the CC version for Version (0x86)... 20:33:24.365 SERIAL « [ACK] (0x06) 20:33:24.367 SERIAL « 0x0104011301e8 (6 bytes) 20:33:24.368 SERIAL » [ACK] (0x06) 20:33:24.368 DRIVER « [RES] [SendData] was sent: true 20:33:24.383 SERIAL « 0x01070013bf00000256 (9 bytes) 20:33:24.383 SERIAL » [ACK] (0x06) 20:33:24.383 DRIVER « [REQ] [SendData] callback id: 191 transmit status: OK 20:33:24.393 SERIAL « 0x010f00040005095e0201050007000700a0 (17 bytes) 20:33:24.394 CNTRLR [Node 005] [+] [Z-Wave Plus Info] zwavePlusVersion: 1 [Endpoint 0] 20:33:24.395 CNTRLR [Node 005] [+] [Z-Wave Plus Info] nodeType: 0 [Endpoint 0] 20:33:24.395 CNTRLR [Node 005] [+] [Z-Wave Plus Info] roleType: 5 [Endpoint 0] 20:33:24.396 CNTRLR [Node 005] [+] [Z-Wave Plus Info] installerIcon: 1792 [Endpoint 0] 20:33:24.396 CNTRLR [Node 005] [+] [Z-Wave Plus Info] userIcon: 1792 [Endpoint 0] 20:33:24.397 SERIAL » [ACK] (0x06) 20:33:24.398 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[ZWavePlusCCReport] version: 1 node type: Node role type: AlwaysOnSlave icon (mgmt.): 0x0700 icon (user): 0x0700 20:33:24.400 SERIAL » 0x0109001306025e0125c05b (11 bytes) 20:33:24.400 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 192 └─[ZWavePlusCCGet] 20:33:24.400 CNTRLR « [Node 005] received response for Z-Wave+ information: Z-Wave+ version: 1 role type: AlwaysOnSlave node type: Node installer icon: 0x0700 user icon: 0x0700 20:33:24.401 CNTRLR [Node 005] [+] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue 20:33:24.406 SERIAL « [ACK] (0x06) 20:33:24.407 SERIAL « 0x0104011301e8 (6 bytes) 20:33:24.407 SERIAL » [ACK] (0x06) 20:33:24.408 DRIVER « [RES] [SendData] was sent: true 20:33:24.410 CNTRLR [Node 005] BinarySwitchCC: doing a complete interview... 20:33:24.410 CNTRLR » [Node 005] querying Binary Switch state... 20:33:24.420 SERIAL « 0x01070013c000000229 (9 bytes) 20:33:24.421 SERIAL » [ACK] (0x06) 20:33:24.421 DRIVER « [REQ] [SendData] callback id: 192 transmit status: OK 20:33:24.431 SERIAL « 0x010f00040006095e0201050007000700a3 (17 bytes) 20:33:24.431 CNTRLR [Node 006] [+] [Z-Wave Plus Info] zwavePlusVersion: 1 [Endpoint 0] 20:33:24.431 CNTRLR [Node 006] [+] [Z-Wave Plus Info] nodeType: 0 [Endpoint 0] 20:33:24.432 CNTRLR [Node 006] [+] [Z-Wave Plus Info] roleType: 5 [Endpoint 0] 20:33:24.432 CNTRLR [Node 006] [+] [Z-Wave Plus Info] installerIcon: 1792 [Endpoint 0] 20:33:24.432 CNTRLR [Node 006] [+] [Z-Wave Plus Info] userIcon: 1792 [Endpoint 0] 20:33:24.432 SERIAL » [ACK] (0x06) 20:33:24.433 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ZWavePlusCCReport] version: 1 node type: Node role type: AlwaysOnSlave icon (mgmt.): 0x0700 icon (user): 0x0700 20:33:24.435 SERIAL » 0x0109001302025e0125c15e (11 bytes) 20:33:24.435 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 193 └─[ZWavePlusCCGet] 20:33:24.435 CNTRLR « [Node 006] received response for Z-Wave+ information: Z-Wave+ version: 1 role type: AlwaysOnSlave node type: Node installer icon: 0x0700 user icon: 0x0700 20:33:24.436 CNTRLR [Node 006] [+] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue 20:33:24.436 CNTRLR [Node 006] BinarySwitchCC: doing a complete interview... 20:33:24.436 CNTRLR » [Node 006] querying Binary Switch state... 20:33:24.439 SERIAL « [ACK] (0x06) 20:33:24.440 SERIAL « 0x0104011301e8 (6 bytes) 20:33:24.440 SERIAL » [ACK] (0x06) 20:33:24.441 DRIVER « [RES] [SendData] was sent: true 20:33:24.459 SERIAL « 0x01070013c100000329 (9 bytes) 20:33:24.460 SERIAL » [ACK] (0x06) 20:33:24.460 DRIVER « [REQ] [SendData] callback id: 193 transmit status: OK 20:33:24.488 SERIAL « 0x010f00040002095e0201050007000700a7 (17 bytes) 20:33:24.489 CNTRLR [Node 002] [+] [Z-Wave Plus Info] zwavePlusVersion: 1 [Endpoint 0] 20:33:24.490 CNTRLR [Node 002] [+] [Z-Wave Plus Info] nodeType: 0 [Endpoint 0] 20:33:24.490 CNTRLR [Node 002] [+] [Z-Wave Plus Info] roleType: 5 [Endpoint 0] 20:33:24.491 CNTRLR [Node 002] [+] [Z-Wave Plus Info] installerIcon: 1792 [Endpoint 0] 20:33:24.491 CNTRLR [Node 002] [+] [Z-Wave Plus Info] userIcon: 1792 [Endpoint 0] 20:33:24.491 SERIAL » [ACK] (0x06) 20:33:24.493 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[ZWavePlusCCReport] version: 1 node type: Node role type: AlwaysOnSlave icon (mgmt.): 0x0700 icon (user): 0x0700 20:33:24.497 SERIAL » 0x010a0013130386138e25c20a (12 bytes) 20:33:24.497 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 194 └─[VersionCCCommandClassGet] CC: Multi Channel Association 20:33:24.497 CNTRLR « [Node 002] received response for Z-Wave+ information: Z-Wave+ version: 1 role type: AlwaysOnSlave node type: Node installer icon: 0x0700 user icon: 0x0700 20:33:24.498 CNTRLR [Node 002] [+] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue 20:33:24.498 CNTRLR [Node 002] BinarySwitchCC: doing a complete interview... 20:33:24.498 CNTRLR » [Node 002] querying Binary Switch state... 20:33:24.504 SERIAL « [ACK] (0x06) 20:33:24.505 SERIAL « 0x0104011301e8 (6 bytes) 20:33:24.505 SERIAL » [ACK] (0x06) 20:33:24.507 DRIVER « [RES] [SendData] was sent: true 20:33:24.644 SERIAL « 0x01070013c200000f26 (9 bytes) 20:33:24.644 SERIAL » [ACK] (0x06) 20:33:24.645 DRIVER « [REQ] [SendData] callback id: 194 transmit status: OK 20:33:24.775 SERIAL « 0x010a000400130486148e03f9 (12 bytes) 20:33:24.775 SERIAL » [ACK] (0x06) 20:33:24.776 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multi Channel Association version: 3 20:33:24.779 SERIAL » 0x010a0013120386137525c3f1 (12 bytes) 20:33:24.780 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 195 └─[VersionCCCommandClassGet] CC: Protection 20:33:24.780 CNTRLR [Node 019] supports CC Multi Channel Association (0x8e) in version 3 20:33:24.780 CNTRLR » [Node 019] querying the CC version for Notification (0x71)... 20:33:24.781 SERIAL « [ACK] (0x06) 20:33:24.785 SERIAL « 0x0104011301e8 (6 bytes) 20:33:24.787 SERIAL » [ACK] (0x06) 20:33:24.788 DRIVER « [RES] [SendData] was sent: true 20:33:24.905 SERIAL « 0x01070013c300000c24 (9 bytes) 20:33:24.905 SERIAL » [ACK] (0x06) 20:33:24.906 DRIVER « [REQ] [SendData] callback id: 195 transmit status: OK 20:33:24.914 SERIAL « 0x010a00040012048614750202 (12 bytes) 20:33:24.915 SERIAL » [ACK] (0x06) 20:33:24.916 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Protection version: 2 20:33:24.919 SERIAL » 0x010a0013140386137125c4f4 (12 bytes) 20:33:24.920 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 196 └─[VersionCCCommandClassGet] CC: Notification 20:33:24.920 CNTRLR [Node 018] supports CC Protection (0x75) in version 2 20:33:24.920 CNTRLR [Node 018] skipping query for Scene Actuator Configuration (0x2c) because ma x implemented version is 0 20:33:24.920 CNTRLR [Node 018] skipping query for Scene Activation (0x2b) because max implemente d version is 1 20:33:24.920 CNTRLR » [Node 018] querying the CC version for Firmware Update Meta Data (0x7a)... 20:33:24.923 SERIAL « [ACK] (0x06) 20:33:24.925 SERIAL « 0x0104011301e8 (6 bytes) 20:33:24.925 SERIAL » [ACK] (0x06) 20:33:24.926 DRIVER « [RES] [SendData] was sent: true 20:33:24.945 SERIAL « 0x01070013c40000022d (9 bytes) 20:33:24.945 SERIAL » [ACK] (0x06) 20:33:24.946 DRIVER « [REQ] [SendData] callback id: 196 transmit status: OK 20:33:24.971 SERIAL « 0x010a00040014048614710103 (12 bytes) 20:33:24.971 SERIAL » [ACK] (0x06) 20:33:24.972 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Notification version: 1 20:33:24.975 SERIAL » 0x010a0013150386133125c5b4 (12 bytes) 20:33:24.975 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 197 └─[VersionCCCommandClassGet] CC: Multilevel Sensor 20:33:24.976 CNTRLR [Node 020] supports CC Notification (0x71) in version 1 20:33:24.976 CNTRLR » [Node 020] querying the CC version for Protection (0x75)... 20:33:24.978 SERIAL « [ACK] (0x06) 20:33:24.981 SERIAL « 0x0104011301e8 (6 bytes) 20:33:24.982 SERIAL » [ACK] (0x06) 20:33:24.982 DRIVER « [RES] [SendData] was sent: true 20:33:26.382 SERIAL « 0x01070013c500008da3 (9 bytes) 20:33:26.383 SERIAL » [ACK] (0x06) 20:33:26.383 DRIVER « [REQ] [SendData] callback id: 197 transmit status: OK 20:33:26.512 SERIAL « 0x010a00040015048614310546 (12 bytes) 20:33:26.513 SERIAL » [ACK] (0x06) 20:33:26.513 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multilevel Sensor version: 5 20:33:26.516 SERIAL » 0x010a0013160386133125c6b4 (12 bytes) 20:33:26.517 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 198 └─[VersionCCCommandClassGet] CC: Multilevel Sensor 20:33:26.517 CNTRLR [Node 021] supports CC Multilevel Sensor (0x31) in version 5 20:33:26.517 CNTRLR » [Node 021] querying the CC version for Multilevel Switch (0x26)... 20:33:26.519 SERIAL « [ACK] (0x06) 20:33:26.523 SERIAL « 0x0104011301e8 (6 bytes) 20:33:26.523 SERIAL » [ACK] (0x06) 20:33:26.524 DRIVER « [RES] [SendData] was sent: true 20:33:27.938 SERIAL « 0x01070013c600008ea3 (9 bytes) 20:33:27.939 SERIAL » [ACK] (0x06) 20:33:27.939 DRIVER « [REQ] [SendData] callback id: 198 transmit status: OK 20:33:28.019 SERIAL « 0x010a00040016048614310545 (12 bytes) 20:33:28.020 SERIAL » [ACK] (0x06) 20:33:28.020 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multilevel Sensor version: 5 20:33:28.023 SERIAL » 0x010a0013170386133125c7b4 (12 bytes) 20:33:28.023 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 199 └─[VersionCCCommandClassGet] CC: Multilevel Sensor 20:33:28.024 CNTRLR [Node 022] supports CC Multilevel Sensor (0x31) in version 5 20:33:28.024 CNTRLR » [Node 022] querying the CC version for Multilevel Switch (0x26)... 20:33:28.025 SERIAL « [ACK] (0x06) 20:33:28.029 SERIAL « 0x0104011301e8 (6 bytes) 20:33:28.029 SERIAL » [ACK] (0x06) 20:33:28.030 DRIVER « [RES] [SendData] was sent: true 20:33:29.456 SERIAL « 0x01070013c700008fa3 (9 bytes) 20:33:29.457 SERIAL » [ACK] (0x06) 20:33:29.458 DRIVER « [REQ] [SendData] callback id: 199 transmit status: OK 20:33:29.532 SERIAL « 0x010a00040017048614310544 (12 bytes) 20:33:29.533 SERIAL » [ACK] (0x06) 20:33:29.534 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multilevel Sensor version: 5 20:33:29.536 SERIAL » 0x010a0013180386133125c8b4 (12 bytes) 20:33:29.537 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 200 └─[VersionCCCommandClassGet] CC: Multilevel Sensor 20:33:29.537 CNTRLR [Node 023] supports CC Multilevel Sensor (0x31) in version 5 20:33:29.537 CNTRLR » [Node 023] querying the CC version for Multilevel Switch (0x26)... 20:33:29.540 SERIAL « [ACK] (0x06) 20:33:29.542 SERIAL « 0x0104011301e8 (6 bytes) 20:33:29.543 SERIAL » [ACK] (0x06) 20:33:29.543 DRIVER « [RES] [SendData] was sent: true 20:33:31.011 SERIAL « 0x01070013c8000094b7 (9 bytes) 20:33:31.011 SERIAL » [ACK] (0x06) 20:33:31.012 DRIVER « [REQ] [SendData] callback id: 200 transmit status: OK 20:33:31.095 SERIAL « 0x010a0004001804861431054b (12 bytes) 20:33:31.095 SERIAL » [ACK] (0x06) 20:33:31.096 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multilevel Sensor version: 5 20:33:31.099 SERIAL » 0x010a00131a0386138e25c908 (12 bytes) 20:33:31.099 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 201 └─[VersionCCCommandClassGet] CC: Multi Channel Association 20:33:31.099 CNTRLR [Node 024] supports CC Multilevel Sensor (0x31) in version 5 20:33:31.099 CNTRLR » [Node 024] querying the CC version for Multilevel Switch (0x26)... 20:33:31.101 SERIAL « [ACK] (0x06) 20:33:31.105 SERIAL « 0x0104011301e8 (6 bytes) 20:33:31.105 SERIAL » [ACK] (0x06) 20:33:31.105 DRIVER « [RES] [SendData] was sent: true 20:33:31.190 SERIAL « 0x01070013c90000082a (9 bytes) 20:33:31.191 SERIAL » [ACK] (0x06) 20:33:31.191 DRIVER « [REQ] [SendData] callback id: 201 transmit status: OK 20:33:31.259 SERIAL « 0x010a0004001a0486148e03f0 (12 bytes) 20:33:31.260 SERIAL » [ACK] (0x06) 20:33:31.261 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multi Channel Association version: 3 20:33:31.263 SERIAL » 0x010a00131c0386138e25ca0d (12 bytes) 20:33:31.264 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 202 └─[VersionCCCommandClassGet] CC: Multi Channel Association 20:33:31.264 CNTRLR [Node 026] supports CC Multi Channel Association (0x8e) in version 3 20:33:31.264 CNTRLR » [Node 026] querying the CC version for Notification (0x71)... 20:33:31.267 SERIAL « [ACK] (0x06) 20:33:31.270 SERIAL « 0x0104011301e8 (6 bytes) 20:33:31.270 SERIAL » [ACK] (0x06) 20:33:31.271 DRIVER « [RES] [SendData] was sent: true 20:33:31.344 SERIAL « 0x01070013ca00000829 (9 bytes) 20:33:31.345 SERIAL » [ACK] (0x06) 20:33:31.345 DRIVER « [REQ] [SendData] callback id: 202 transmit status: OK 20:33:31.354 SERIAL « 0x010a0004001c0486148e03f6 (12 bytes) 20:33:31.355 SERIAL » [ACK] (0x06) 20:33:31.355 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multi Channel Association version: 3 20:33:31.358 SERIAL » 0x010a0013030386138625cb1b (12 bytes) 20:33:31.358 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 203 └─[VersionCCCommandClassGet] CC: Version 20:33:31.359 CNTRLR [Node 028] supports CC Multi Channel Association (0x8e) in version 3 20:33:31.359 CNTRLR » [Node 028] querying the CC version for Notification (0x71)... 20:33:31.364 SERIAL « [ACK] (0x06) 20:33:31.365 SERIAL « 0x0104011301e8 (6 bytes) 20:33:31.366 SERIAL » [ACK] (0x06) 20:33:31.366 DRIVER « [RES] [SendData] was sent: true 20:33:31.383 SERIAL « 0x01070013cb00000222 (9 bytes) 20:33:31.383 SERIAL » [ACK] (0x06) 20:33:31.384 DRIVER « [REQ] [SendData] callback id: 203 transmit status: OK 20:33:31.396 SERIAL « 0x010a000400030486148602e0 (12 bytes) 20:33:31.397 SERIAL » [ACK] (0x06) 20:33:31.397 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 2 20:33:31.400 SERIAL » 0x010900130502250225cc2c (11 bytes) 20:33:31.400 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 204 └─[BinarySwitchCCGet] 20:33:31.401 CNTRLR [Node 003] supports CC Version (0x86) in version 2 20:33:31.401 CNTRLR [Node 003] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 20:33:31.401 CNTRLR [Node 003] trying to load device config 20:33:31.404 SERIAL « [ACK] (0x06) 20:33:31.417 CNTRLR [Node 003] device config loaded 20:33:31.417 SERIAL « 0x0104011301e8 (6 bytes) 20:33:31.417 SERIAL » [ACK] (0x06) 20:33:31.418 DRIVER « [RES] [SendData] was sent: true 20:33:31.423 SERIAL « 0x01070013cc00000225 (9 bytes) 20:33:31.423 SERIAL » [ACK] (0x06) 20:33:31.424 DRIVER « [REQ] [SendData] callback id: 204 transmit status: OK 20:33:31.426 CNTRLR [Node 003] ZWavePlusCC: doing a complete interview... 20:33:31.426 CNTRLR » [Node 003] querying Z-Wave+ information... 20:33:31.430 SERIAL « 0x01090004000503250300d2 (11 bytes) 20:33:31.431 CNTRLR [Node 005] [+] [Binary Switch] currentValue: false [Endpoint 0] 20:33:31.432 SERIAL » [ACK] (0x06) 20:33:31.433 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 20:33:31.435 SERIAL » 0x010900130602250225cd2e (11 bytes) 20:33:31.435 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 205 └─[BinarySwitchCCGet] 20:33:31.436 CNTRLR « [Node 005] received Binary Switch state: current value: false 20:33:31.436 CNTRLR [Node 005] [+] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] 20:33:31.437 CNTRLR [Node 005] ConfigurationCC: Loading configuration parameters from device confi g 20:33:31.438 CNTRLR [Node 005] [+] [Configuration] isParamInformationFromConfig: false [internal] 20:33:31.439 CNTRLR [Node 005] [Configuration] 1: metadata updated 20:33:31.440 CNTRLR [Node 005] [Configuration] 2: metadata updated 20:33:31.440 CNTRLR [Node 005] [Configuration] 3: metadata updated 20:33:31.441 CNTRLR [Node 005] [Configuration] 4: metadata updated 20:33:31.442 CNTRLR [Node 005] [Configuration] 5: metadata updated 20:33:31.442 CNTRLR [Node 005] [Configuration] 6: metadata updated 20:33:31.443 CNTRLR [Node 005] [Configuration] 7: metadata updated 20:33:31.443 CNTRLR [Node 005] [Configuration] 8: metadata updated 20:33:31.444 CNTRLR [Node 005] [Configuration] 9: metadata updated 20:33:31.444 CNTRLR [Node 005] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 20:33:31.445 CNTRLR » [Node 005] querying parameter #1 value... 20:33:31.470 SERIAL « [ACK] (0x06) 20:33:31.470 SERIAL « 0x0104011301e8 (6 bytes) 20:33:31.471 SERIAL » [ACK] (0x06) 20:33:31.471 DRIVER « [RES] [SendData] was sent: true 20:33:31.479 SERIAL « 0x01070013cd00000224 (9 bytes) 20:33:31.479 SERIAL » [ACK] (0x06) 20:33:31.480 DRIVER « [REQ] [SendData] callback id: 205 transmit status: OK 20:33:31.482 SERIAL « 0x01090004000603250300d1 (11 bytes) 20:33:31.483 CNTRLR [Node 006] [+] [Binary Switch] currentValue: false [Endpoint 0] 20:33:31.483 SERIAL » [ACK] (0x06) 20:33:31.483 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 20:33:31.484 SERIAL » 0x010900130202250225ce29 (11 bytes) 20:33:31.485 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 206 └─[BinarySwitchCCGet] 20:33:31.485 CNTRLR « [Node 006] received Binary Switch state: current value: false 20:33:31.485 CNTRLR [Node 006] [+] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] 20:33:31.485 CNTRLR [Node 006] ConfigurationCC: Loading configuration parameters from device confi g 20:33:31.485 CNTRLR [Node 006] [+] [Configuration] isParamInformationFromConfig: false [internal] 20:33:31.486 CNTRLR [Node 006] [Configuration] 1: metadata updated 20:33:31.486 CNTRLR [Node 006] [Configuration] 2: metadata updated 20:33:31.486 CNTRLR [Node 006] [Configuration] 3: metadata updated 20:33:31.487 CNTRLR [Node 006] [Configuration] 4: metadata updated 20:33:31.487 CNTRLR [Node 006] [Configuration] 5: metadata updated 20:33:31.488 CNTRLR [Node 006] [Configuration] 6: metadata updated 20:33:31.488 CNTRLR [Node 006] [Configuration] 7: metadata updated 20:33:31.489 CNTRLR [Node 006] [Configuration] 8: metadata updated 20:33:31.489 CNTRLR [Node 006] [Configuration] 9: metadata updated 20:33:31.489 CNTRLR [Node 006] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 20:33:31.489 CNTRLR » [Node 006] querying parameter #1 value... 20:33:31.494 SERIAL « [ACK] (0x06) 20:33:31.494 SERIAL « 0x0104011301e8 (6 bytes) 20:33:31.494 SERIAL » [ACK] (0x06) 20:33:31.496 DRIVER « [RES] [SendData] was sent: true 20:33:31.509 SERIAL « 0x01070013ce00000227 (9 bytes) 20:33:31.509 SERIAL » [ACK] (0x06) 20:33:31.509 DRIVER « [REQ] [SendData] callback id: 206 transmit status: OK 20:33:31.536 SERIAL « 0x01090004000203250300d5 (11 bytes) 20:33:31.536 CNTRLR [Node 002] [+] [Binary Switch] currentValue: false [Endpoint 0] 20:33:31.537 SERIAL » [ACK] (0x06) 20:33:31.537 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 20:33:31.538 SERIAL » 0x010a0013130386137125cff8 (12 bytes) 20:33:31.538 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 207 └─[VersionCCCommandClassGet] CC: Notification 20:33:31.539 CNTRLR « [Node 002] received Binary Switch state: current value: false 20:33:31.539 CNTRLR [Node 002] [+] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] 20:33:31.539 CNTRLR [Node 002] MeterCC: doing a complete interview... 20:33:31.540 CNTRLR » [Node 002] querying meter support... 20:33:31.558 SERIAL « [ACK] (0x06) 20:33:31.558 SERIAL « 0x0104011301e8 (6 bytes) 20:33:31.558 SERIAL » [ACK] (0x06) 20:33:31.558 DRIVER « [RES] [SendData] was sent: true 20:33:31.686 SERIAL « 0x01070013cf00000e2a (9 bytes) 20:33:31.686 SERIAL » [ACK] (0x06) 20:33:31.687 DRIVER « [REQ] [SendData] callback id: 207 transmit status: OK 20:33:31.815 SERIAL « 0x010a00040013048614710500 (12 bytes) 20:33:31.815 SERIAL » [ACK] (0x06) 20:33:31.816 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Notification version: 5 20:33:31.819 SERIAL » 0x010a0013120386137a25d0ed (12 bytes) 20:33:31.819 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 208 └─[VersionCCCommandClassGet] CC: Firmware Update Meta Data 20:33:31.819 CNTRLR [Node 019] supports CC Notification (0x71) in version 5 20:33:31.820 CNTRLR [Node 019] skipping query for Powerlevel (0x73) because max implemented vers ion is 0 20:33:31.820 CNTRLR [Node 019] skipping query for Security (0x98) because max implemented versio n is 1 20:33:31.820 CNTRLR » [Node 019] querying the CC version for Multilevel Sensor (0x31)... 20:33:31.822 SERIAL « [ACK] (0x06) 20:33:31.825 SERIAL « 0x0104011301e8 (6 bytes) 20:33:31.825 SERIAL » [ACK] (0x06) 20:33:31.825 DRIVER « [RES] [SendData] was sent: true 20:33:31.944 SERIAL « 0x01070013d000000c37 (9 bytes) 20:33:31.945 SERIAL » [ACK] (0x06) 20:33:31.945 DRIVER « [REQ] [SendData] callback id: 208 transmit status: OK 20:33:31.954 SERIAL « 0x010a000400120486147a020d (12 bytes) 20:33:31.955 SERIAL » [ACK] (0x06) 20:33:31.956 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Firmware Update Meta Data version: 2 20:33:31.961 SERIAL » 0x010a0013140386137525d1e5 (12 bytes) 20:33:31.961 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 209 └─[VersionCCCommandClassGet] CC: Protection 20:33:31.961 CNTRLR [Node 018] supports CC Firmware Update Meta Data (0x7a) in version 2 20:33:31.962 CNTRLR [Node 018] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 20:33:31.962 CNTRLR [Node 018] trying to load device config 20:33:31.965 SERIAL « [ACK] (0x06) 20:33:31.970 CNTRLR [Node 018] device config loaded 20:33:31.976 SERIAL « 0x0104011301e8 (6 bytes) 20:33:31.977 SERIAL » [ACK] (0x06) 20:33:31.978 DRIVER « [RES] [SendData] was sent: true 20:33:31.979 CNTRLR [Node 018] ZWavePlusCC: doing a complete interview... 20:33:31.980 CNTRLR » [Node 018] querying Z-Wave+ information... 20:33:31.986 SERIAL « 0x01070013d100000238 (9 bytes) 20:33:31.986 SERIAL » [ACK] (0x06) 20:33:31.993 DRIVER « [REQ] [SendData] callback id: 209 transmit status: OK 20:33:32.014 SERIAL « 0x010a00040014048614750204 (12 bytes) 20:33:32.014 SERIAL » [ACK] (0x06) 20:33:32.015 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Protection version: 2 20:33:32.018 SERIAL » 0x010a0013150386132625d2b4 (12 bytes) 20:33:32.018 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 210 └─[VersionCCCommandClassGet] CC: Multilevel Switch 20:33:32.018 CNTRLR [Node 020] supports CC Protection (0x75) in version 2 20:33:32.019 CNTRLR » [Node 020] querying the CC version for Firmware Update Meta Data (0x7a)... 20:33:32.021 SERIAL « [ACK] (0x06) 20:33:32.024 SERIAL « 0x0104011301e8 (6 bytes) 20:33:32.024 SERIAL » [ACK] (0x06) 20:33:32.024 DRIVER « [RES] [SendData] was sent: true 20:33:33.461 SERIAL « 0x01070013d2000090a9 (9 bytes) 20:33:33.461 SERIAL » [ACK] (0x06) 20:33:33.462 DRIVER « [REQ] [SendData] callback id: 210 transmit status: OK 20:33:33.539 SERIAL « 0x010a00040015048614260155 (12 bytes) 20:33:33.540 SERIAL » [ACK] (0x06) 20:33:33.540 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multilevel Switch version: 1 20:33:33.543 SERIAL » 0x010a0013160386132625d3b6 (12 bytes) 20:33:33.543 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 211 └─[VersionCCCommandClassGet] CC: Multilevel Switch 20:33:33.544 CNTRLR [Node 021] supports CC Multilevel Switch (0x26) in version 1 20:33:33.544 CNTRLR » [Node 021] querying the CC version for Battery (0x80)... 20:33:33.545 SERIAL « [ACK] (0x06) 20:33:33.549 SERIAL « 0x0104011301e8 (6 bytes) 20:33:33.549 SERIAL » [ACK] (0x06) 20:33:33.550 DRIVER « [RES] [SendData] was sent: true 20:33:35.011 SERIAL « 0x01070013d3000093ab (9 bytes) 20:33:35.011 SERIAL » [ACK] (0x06) 20:33:35.012 DRIVER « [REQ] [SendData] callback id: 211 transmit status: OK 20:33:35.096 SERIAL « 0x010a00040016048614260156 (12 bytes) 20:33:35.096 SERIAL » [ACK] (0x06) 20:33:35.097 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multilevel Switch version: 1 20:33:35.101 SERIAL » 0x010a0013170386132625d4b0 (12 bytes) 20:33:35.101 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 212 └─[VersionCCCommandClassGet] CC: Multilevel Switch 20:33:35.101 CNTRLR [Node 022] supports CC Multilevel Switch (0x26) in version 1 20:33:35.101 CNTRLR » [Node 022] querying the CC version for Battery (0x80)... 20:33:35.103 SERIAL « [ACK] (0x06) 20:33:35.107 SERIAL « 0x0104011301e8 (6 bytes) 20:33:35.107 SERIAL » [ACK] (0x06) 20:33:35.107 DRIVER « [RES] [SendData] was sent: true 20:33:36.553 SERIAL « 0x01070013d4000091ae (9 bytes) 20:33:36.554 SERIAL » [ACK] (0x06) 20:33:36.554 DRIVER « [REQ] [SendData] callback id: 212 transmit status: OK 20:33:36.632 SERIAL « 0x010a00040017048614260157 (12 bytes) 20:33:36.632 SERIAL » [ACK] (0x06) 20:33:36.633 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multilevel Switch version: 1 20:33:36.635 SERIAL » 0x010a0013180386132625d5be (12 bytes) 20:33:36.635 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 213 └─[VersionCCCommandClassGet] CC: Multilevel Switch 20:33:36.635 CNTRLR [Node 023] supports CC Multilevel Switch (0x26) in version 1 20:33:36.635 CNTRLR » [Node 023] querying the CC version for Battery (0x80)... 20:33:36.640 SERIAL « [ACK] (0x06) 20:33:36.641 SERIAL « 0x0104011301e8 (6 bytes) 20:33:36.641 SERIAL » [ACK] (0x06) 20:33:36.641 DRIVER « [RES] [SendData] was sent: true 20:33:38.058 SERIAL « 0x01070013d500008eb0 (9 bytes) 20:33:38.059 SERIAL » [ACK] (0x06) 20:33:38.060 DRIVER « [REQ] [SendData] callback id: 213 transmit status: OK 20:33:38.141 SERIAL « 0x010a00040018048614260158 (12 bytes) 20:33:38.141 SERIAL » [ACK] (0x06) 20:33:38.142 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multilevel Switch version: 1 20:33:38.144 SERIAL » 0x010a00131a0386137125d6e8 (12 bytes) 20:33:38.145 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 214 └─[VersionCCCommandClassGet] CC: Notification 20:33:38.145 CNTRLR [Node 024] supports CC Multilevel Switch (0x26) in version 1 20:33:38.145 CNTRLR » [Node 024] querying the CC version for Battery (0x80)... 20:33:38.146 SERIAL « [ACK] (0x06) 20:33:38.151 SERIAL « 0x0104011301e8 (6 bytes) 20:33:38.151 SERIAL » [ACK] (0x06) 20:33:38.151 DRIVER « [RES] [SendData] was sent: true 20:33:38.250 SERIAL « 0x01070013d600000b36 (9 bytes) 20:33:38.250 SERIAL » [ACK] (0x06) 20:33:38.251 DRIVER « [REQ] [SendData] callback id: 214 transmit status: OK 20:33:38.321 SERIAL « 0x010a0004001a048614710509 (12 bytes) 20:33:38.321 SERIAL » [ACK] (0x06) 20:33:38.322 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Notification version: 5 20:33:38.325 SERIAL » 0x010a00131c0386137125d7ef (12 bytes) 20:33:38.325 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 215 └─[VersionCCCommandClassGet] CC: Notification 20:33:38.325 CNTRLR [Node 026] supports CC Notification (0x71) in version 5 20:33:38.326 CNTRLR [Node 026] skipping query for Powerlevel (0x73) because max implemented vers ion is 0 20:33:38.326 CNTRLR [Node 026] skipping query for Security (0x98) because max implemented versio n is 1 20:33:38.326 CNTRLR » [Node 026] querying the CC version for Multilevel Sensor (0x31)... 20:33:38.328 SERIAL « [ACK] (0x06) 20:33:38.331 SERIAL « 0x0104011301e8 (6 bytes) 20:33:38.331 SERIAL » [ACK] (0x06) 20:33:38.332 DRIVER « [RES] [SendData] was sent: true 20:33:38.404 SERIAL « 0x01070013d700000834 (9 bytes) 20:33:38.405 SERIAL » [ACK] (0x06) 20:33:38.406 DRIVER « [REQ] [SendData] callback id: 215 transmit status: OK 20:33:38.414 SERIAL « 0x010a0004001c04861471050f (12 bytes) 20:33:38.415 SERIAL » [ACK] (0x06) 20:33:38.415 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Notification version: 5 20:33:38.418 SERIAL » 0x0109001303025e0125d846 (11 bytes) 20:33:38.418 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 216 └─[ZWavePlusCCGet] 20:33:38.419 CNTRLR [Node 028] supports CC Notification (0x71) in version 5 20:33:38.419 CNTRLR [Node 028] skipping query for Powerlevel (0x73) because max implemented vers ion is 0 20:33:38.419 CNTRLR [Node 028] skipping query for Security (0x98) because max implemented versio n is 1 20:33:38.424 CNTRLR » [Node 028] querying the CC version for Multilevel Sensor (0x31)... 20:33:38.428 SERIAL « [ACK] (0x06) 20:33:38.440 SERIAL « 0x0104011301e8 (6 bytes) 20:33:38.440 SERIAL » [ACK] (0x06) 20:33:38.440 DRIVER « [RES] [SendData] was sent: true 20:33:38.444 SERIAL « 0x01070013d800000231 (9 bytes) 20:33:38.444 SERIAL » [ACK] (0x06) 20:33:38.445 DRIVER « [REQ] [SendData] callback id: 216 transmit status: OK 20:33:38.457 SERIAL « 0x010f00040003095e0201050007000700a6 (17 bytes) 20:33:38.457 CNTRLR [Node 003] [+] [Z-Wave Plus Info] zwavePlusVersion: 1 [Endpoint 0] 20:33:38.458 CNTRLR [Node 003] [+] [Z-Wave Plus Info] nodeType: 0 [Endpoint 0] 20:33:38.458 CNTRLR [Node 003] [+] [Z-Wave Plus Info] roleType: 5 [Endpoint 0] 20:33:38.458 CNTRLR [Node 003] [+] [Z-Wave Plus Info] installerIcon: 1792 [Endpoint 0] 20:33:38.458 CNTRLR [Node 003] [+] [Z-Wave Plus Info] userIcon: 1792 [Endpoint 0] 20:33:38.458 SERIAL » [ACK] (0x06) 20:33:38.459 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ZWavePlusCCReport] version: 1 node type: Node role type: AlwaysOnSlave icon (mgmt.): 0x0700 icon (user): 0x0700 20:33:38.460 SERIAL » 0x010a0013050370050125d968 (12 bytes) 20:33:38.461 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 217 └─[ConfigurationCCGet] parameter #: 1 20:33:38.461 CNTRLR « [Node 003] received response for Z-Wave+ information: Z-Wave+ version: 1 role type: AlwaysOnSlave node type: Node installer icon: 0x0700 user icon: 0x0700 20:33:38.461 CNTRLR [Node 003] [+] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue 20:33:38.465 SERIAL « [ACK] (0x06) 20:33:38.467 CNTRLR [Node 003] BinarySwitchCC: doing a complete interview... 20:33:38.467 CNTRLR » [Node 003] querying Binary Switch state... 20:33:38.468 SERIAL « 0x0104011301e8 (6 bytes) 20:33:38.468 SERIAL » [ACK] (0x06) 20:33:38.468 DRIVER « [RES] [SendData] was sent: true 20:33:38.481 SERIAL « 0x01070013d900000230 (9 bytes) 20:33:38.482 SERIAL » [ACK] (0x06) 20:33:38.482 DRIVER « [REQ] [SendData] callback id: 217 transmit status: OK 20:33:38.492 SERIAL « 0x010c00040005067006010213881a (14 bytes) 20:33:38.495 CNTRLR [Node 005] [+] [Configuration] 1: 5000 20:33:38.497 SERIAL » [ACK] (0x06) 20:33:38.498 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 2 value: 5000 20:33:38.502 SERIAL » 0x010a0013060370050125da68 (12 bytes) 20:33:38.502 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 218 └─[ConfigurationCCGet] parameter #: 1 20:33:38.503 CNTRLR « [Node 005] parameter #1 has value: 5000 20:33:38.503 CNTRLR » [Node 005] querying parameter #2 value... 20:33:38.508 SERIAL « [ACK] (0x06) 20:33:38.509 SERIAL « 0x0104011301e8 (6 bytes) 20:33:38.509 SERIAL » [ACK] (0x06) 20:33:38.509 DRIVER « [RES] [SendData] was sent: true 20:33:38.526 SERIAL « 0x01070013da00000233 (9 bytes) 20:33:38.526 SERIAL » [ACK] (0x06) 20:33:38.527 DRIVER « [REQ] [SendData] callback id: 218 transmit status: OK 20:33:38.536 SERIAL « 0x010c00040006067006010202d050 (14 bytes) 20:33:38.537 CNTRLR [Node 006] [+] [Configuration] 1: 720 20:33:38.537 SERIAL » [ACK] (0x06) 20:33:38.537 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 2 value: 720 20:33:38.539 SERIAL » 0x010900130202320325db2a (11 bytes) 20:33:38.539 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 219 └─[MeterCCSupportedGet] 20:33:38.539 CNTRLR « [Node 006] parameter #1 has value: 720 20:33:38.539 CNTRLR » [Node 006] querying parameter #2 value... 20:33:38.540 SERIAL « [ACK] (0x06) 20:33:38.544 SERIAL « 0x0104011301e8 (6 bytes) 20:33:38.544 SERIAL » [ACK] (0x06) 20:33:38.544 DRIVER « [RES] [SendData] was sent: true 20:33:38.563 SERIAL « 0x01070013db00000232 (9 bytes) 20:33:38.563 SERIAL » [ACK] (0x06) 20:33:38.564 DRIVER « [REQ] [SendData] callback id: 219 transmit status: OK 20:33:38.588 SERIAL « 0x010a00040002043204817535 (12 bytes) 20:33:38.590 CNTRLR [Node 002] [+] [Meter] type: 1 [Endpoint 0] [internal] 20:33:38.590 CNTRLR [Node 002] [+] [Meter] supportsReset: true [Endpoint 0] [internal] 20:33:38.590 CNTRLR [Node 002] [+] [Meter] supportedScales: 0,2,4,5,6 [Endpoint 0] [internal] 20:33:38.591 CNTRLR [Node 002] [+] [Meter] supportedRateTypes: [Endpoint 0] [internal] 20:33:38.591 CNTRLR [Node 002] [Meter] reset: metadata updated [Endpoint 0] 20:33:38.592 SERIAL » [ACK] (0x06) 20:33:38.593 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[MeterCCSupportedReport] type: Electric supports reset: true supported scales: · kWh · W · V · A · Power Factor supported rate types: 20:33:38.596 SERIAL » 0x010a0013130386133125dcab (12 bytes) 20:33:38.596 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 220 └─[VersionCCCommandClassGet] CC: Multilevel Sensor 20:33:38.597 CNTRLR « [Node 002] received meter support: type: Electric supported scales: · kWh · W · V · A · Power Factor supported rate types: supports reset: true 20:33:38.597 CNTRLR » [Node 002] querying meter value (type = Electric, scale = kWh)... 20:33:38.600 SERIAL « [ACK] (0x06) 20:33:38.601 SERIAL « 0x0104011301e8 (6 bytes) 20:33:38.602 SERIAL » [ACK] (0x06) 20:33:38.602 DRIVER « [RES] [SendData] was sent: true 20:33:38.742 SERIAL « 0x01070013dc00000f38 (9 bytes) 20:33:38.743 SERIAL » [ACK] (0x06) 20:33:38.743 DRIVER « [REQ] [SendData] callback id: 220 transmit status: OK 20:33:38.875 SERIAL « 0x010a00040013048614310540 (12 bytes) 20:33:38.876 SERIAL » [ACK] (0x06) 20:33:38.876 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multilevel Sensor version: 5 20:33:38.879 SERIAL » 0x0109001312025e0125dd52 (11 bytes) 20:33:38.879 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 221 └─[ZWavePlusCCGet] 20:33:38.880 CNTRLR [Node 019] supports CC Multilevel Sensor (0x31) in version 5 20:33:38.880 CNTRLR » [Node 019] querying the CC version for Version (0x86)... 20:33:38.882 SERIAL « [ACK] (0x06) 20:33:38.885 SERIAL « 0x0104011301e8 (6 bytes) 20:33:38.885 SERIAL » [ACK] (0x06) 20:33:38.886 DRIVER « [RES] [SendData] was sent: true 20:33:39.004 SERIAL « 0x01070013dd00000c3a (9 bytes) 20:33:39.004 SERIAL » [ACK] (0x06) 20:33:39.005 DRIVER « [REQ] [SendData] callback id: 221 transmit status: OK 20:33:39.015 SERIAL « 0x010f00040012095e0201050007000700b7 (17 bytes) 20:33:39.016 CNTRLR [Node 018] [+] [Z-Wave Plus Info] zwavePlusVersion: 1 [Endpoint 0] 20:33:39.016 CNTRLR [Node 018] [+] [Z-Wave Plus Info] nodeType: 0 [Endpoint 0] 20:33:39.017 CNTRLR [Node 018] [+] [Z-Wave Plus Info] roleType: 5 [Endpoint 0] 20:33:39.017 CNTRLR [Node 018] [+] [Z-Wave Plus Info] installerIcon: 1792 [Endpoint 0] 20:33:39.018 CNTRLR [Node 018] [+] [Z-Wave Plus Info] userIcon: 1792 [Endpoint 0] 20:33:39.018 SERIAL » [ACK] (0x06) 20:33:39.020 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[ZWavePlusCCReport] version: 1 node type: Node role type: AlwaysOnSlave icon (mgmt.): 0x0700 icon (user): 0x0700 20:33:39.022 SERIAL » 0x010a0013140386137a25dee5 (12 bytes) 20:33:39.023 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 222 └─[VersionCCCommandClassGet] CC: Firmware Update Meta Data 20:33:39.023 CNTRLR « [Node 018] received response for Z-Wave+ information: Z-Wave+ version: 1 role type: AlwaysOnSlave node type: Node installer icon: 0x0700 user icon: 0x0700 20:33:39.024 CNTRLR [Node 018] [+] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue 20:33:39.034 SERIAL « [ACK] (0x06) 20:33:39.035 SERIAL « 0x0104011301e8 (6 bytes) 20:33:39.035 SERIAL » [ACK] (0x06) 20:33:39.036 DRIVER « [RES] [SendData] was sent: true 20:33:39.039 CNTRLR [Node 018] BinarySwitchCC: doing a complete interview... 20:33:39.039 CNTRLR » [Node 018] querying Binary Switch state... 20:33:39.048 SERIAL « 0x01070013de00000237 (9 bytes) 20:33:39.048 SERIAL » [ACK] (0x06) 20:33:39.049 DRIVER « [REQ] [SendData] callback id: 222 transmit status: OK 20:33:39.076 SERIAL « 0x010a000400140486147a020b (12 bytes) 20:33:39.076 SERIAL » [ACK] (0x06) 20:33:39.077 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Firmware Update Meta Data version: 2 20:33:39.080 SERIAL » 0x010a0013150386138025df1f (12 bytes) 20:33:39.081 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 223 └─[VersionCCCommandClassGet] CC: Battery 20:33:39.081 CNTRLR [Node 020] supports CC Firmware Update Meta Data (0x7a) in version 2 20:33:39.081 CNTRLR [Node 020] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 20:33:39.082 CNTRLR [Node 020] trying to load device config 20:33:39.084 SERIAL « [ACK] (0x06) 20:33:39.086 SERIAL « 0x0104011301e8 (6 bytes) 20:33:39.086 SERIAL » [ACK] (0x06) 20:33:39.091 CNTRLR [Node 020] device config loaded 20:33:39.092 CNTRLR [Node 020] ZWavePlusCC: doing a complete interview... 20:33:39.092 CNTRLR » [Node 020] querying Z-Wave+ information... 20:33:39.094 DRIVER « [RES] [SendData] was sent: true 20:33:40.435 SERIAL « 0x01070013df000087b3 (9 bytes) 20:33:40.436 SERIAL » [ACK] (0x06) 20:33:40.436 DRIVER « [REQ] [SendData] callback id: 223 transmit status: OK 20:33:40.514 SERIAL « 0x010a000400150486148001f3 (12 bytes) 20:33:40.514 SERIAL » [ACK] (0x06) 20:33:40.515 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Battery version: 1 20:33:40.518 SERIAL » 0x010a0013160386138025e023 (12 bytes) 20:33:40.519 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 224 └─[VersionCCCommandClassGet] CC: Battery 20:33:40.519 CNTRLR [Node 021] supports CC Battery (0x80) in version 1 20:33:40.519 CNTRLR » [Node 021] querying the CC version for Configuration (0x70)... 20:33:40.520 SERIAL « [ACK] (0x06) 20:33:40.525 SERIAL « 0x0104011301e8 (6 bytes) 20:33:40.525 SERIAL » [ACK] (0x06) 20:33:40.525 DRIVER « [RES] [SendData] was sent: true 20:33:42.000 SERIAL « 0x01070013e00000949f (9 bytes) 20:33:42.001 SERIAL » [ACK] (0x06) 20:33:42.001 DRIVER « [REQ] [SendData] callback id: 224 transmit status: OK 20:33:42.077 SERIAL « 0x010a000400160486148001f0 (12 bytes) 20:33:42.077 SERIAL » [ACK] (0x06) 20:33:42.078 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Battery version: 1 20:33:42.081 SERIAL » 0x010a0013170386138025e123 (12 bytes) 20:33:42.082 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 225 └─[VersionCCCommandClassGet] CC: Battery 20:33:42.082 CNTRLR [Node 022] supports CC Battery (0x80) in version 1 20:33:42.082 CNTRLR » [Node 022] querying the CC version for Configuration (0x70)... 20:33:42.083 SERIAL « [ACK] (0x06) 20:33:42.087 SERIAL « 0x0104011301e8 (6 bytes) 20:33:42.088 SERIAL » [ACK] (0x06) 20:33:42.088 DRIVER « [RES] [SendData] was sent: true 20:33:43.517 SERIAL « 0x01070013e100008f85 (9 bytes) 20:33:43.517 SERIAL » [ACK] (0x06) 20:33:43.517 DRIVER « [REQ] [SendData] callback id: 225 transmit status: OK 20:33:43.596 SERIAL « 0x010a000400170486148001f1 (12 bytes) 20:33:43.596 SERIAL » [ACK] (0x06) 20:33:43.597 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Battery version: 1 20:33:43.598 SERIAL » 0x010a0013180386138025e22f (12 bytes) 20:33:43.598 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 226 └─[VersionCCCommandClassGet] CC: Battery 20:33:43.598 CNTRLR [Node 023] supports CC Battery (0x80) in version 1 20:33:43.598 CNTRLR » [Node 023] querying the CC version for Configuration (0x70)... 20:33:43.599 SERIAL « [ACK] (0x06) 20:33:43.603 SERIAL « 0x0104011301e8 (6 bytes) 20:33:43.603 SERIAL » [ACK] (0x06) 20:33:43.604 DRIVER « [RES] [SendData] was sent: true 20:33:45.071 SERIAL « 0x0110000400120a32022134000000010000d7 (18 bytes) 20:33:45.073 CNTRLR [Node 018] [Meter] value[66049]: metadata updated [Endpoint 0] 20:33:45.073 CNTRLR [Node 018] [Meter] previousValue[66049]: metadata updated [Endpoint 0] 20:33:45.074 CNTRLR [Node 018] [Meter] deltaTime[66049]: metadata updated [Endpoint 0] 20:33:45.075 CNTRLR [Node 018] [+] [Meter] value[66049]: 0.1 [Endpoint 0] 20:33:45.076 CNTRLR [Node 018] [+] [Meter] deltaTime[66049]: 0 [Endpoint 0] 20:33:45.076 SERIAL » [ACK] (0x06) 20:33:45.077 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0.1 time delta: 0 seconds 20:33:45.094 SERIAL « 0x01070013e20000959c (9 bytes) 20:33:45.094 SERIAL » [ACK] (0x06) 20:33:45.095 DRIVER « [REQ] [SendData] callback id: 226 transmit status: OK 20:33:45.141 SERIAL « 0x0110000400120a32022134000000010000d7 (18 bytes) 20:33:45.143 CNTRLR [Node 018] [~] [Meter] value[66049]: 0.1 => 0.1 [Endpoint 0] 20:33:45.143 CNTRLR [Node 018] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:33:45.144 SERIAL » [ACK] (0x06) 20:33:45.145 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0.1 time delta: 0 seconds 20:33:45.176 SERIAL « 0x010a000400180486148001fe (12 bytes) 20:33:45.176 SERIAL » [ACK] (0x06) 20:33:45.177 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Battery version: 1 20:33:45.180 SERIAL » 0x010a00131a0386133125e39d (12 bytes) 20:33:45.181 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 227 └─[VersionCCCommandClassGet] CC: Multilevel Sensor 20:33:45.181 CNTRLR [Node 024] supports CC Battery (0x80) in version 1 20:33:45.181 CNTRLR » [Node 024] querying the CC version for Configuration (0x70)... 20:33:45.184 SERIAL « [ACK] (0x06) 20:33:45.187 SERIAL « 0x0104011301e8 (6 bytes) 20:33:45.187 SERIAL » [ACK] (0x06) 20:33:45.188 DRIVER « [RES] [SendData] was sent: true 20:33:45.290 SERIAL « 0x01070013e300000a02 (9 bytes) 20:33:45.290 SERIAL » [ACK] (0x06) 20:33:45.291 DRIVER « [REQ] [SendData] callback id: 227 transmit status: OK 20:33:45.361 SERIAL « 0x010a0004001a048614310549 (12 bytes) 20:33:45.361 SERIAL » [ACK] (0x06) 20:33:45.362 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multilevel Sensor version: 5 20:33:45.365 SERIAL » 0x010a00131c0386133125e49c (12 bytes) 20:33:45.366 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 228 └─[VersionCCCommandClassGet] CC: Multilevel Sensor 20:33:45.366 CNTRLR [Node 026] supports CC Multilevel Sensor (0x31) in version 5 20:33:45.366 CNTRLR » [Node 026] querying the CC version for Version (0x86)... 20:33:45.373 SERIAL « [ACK] (0x06) 20:33:45.374 SERIAL « 0x0104011301e8 (6 bytes) 20:33:45.374 SERIAL » [ACK] (0x06) 20:33:45.375 DRIVER « [RES] [SendData] was sent: true 20:33:45.444 SERIAL « 0x01070013e400000807 (9 bytes) 20:33:45.445 SERIAL » [ACK] (0x06) 20:33:45.446 DRIVER « [REQ] [SendData] callback id: 228 transmit status: OK 20:33:45.454 SERIAL « 0x010a0004001c04861431054f (12 bytes) 20:33:45.455 SERIAL » [ACK] (0x06) 20:33:45.455 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multilevel Sensor version: 5 20:33:45.458 SERIAL » 0x010900130302250225e503 (11 bytes) 20:33:45.458 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 229 └─[BinarySwitchCCGet] 20:33:45.459 CNTRLR [Node 028] supports CC Multilevel Sensor (0x31) in version 5 20:33:45.459 CNTRLR » [Node 028] querying the CC version for Version (0x86)... 20:33:45.462 SERIAL « [ACK] (0x06) 20:33:45.464 SERIAL « 0x0104011301e8 (6 bytes) 20:33:45.464 SERIAL » [ACK] (0x06) 20:33:45.464 DRIVER « [RES] [SendData] was sent: true 20:33:45.483 SERIAL « 0x01070013e50000020c (9 bytes) 20:33:45.484 SERIAL » [ACK] (0x06) 20:33:45.484 DRIVER « [REQ] [SendData] callback id: 229 transmit status: OK 20:33:45.495 SERIAL « 0x01090004000303250300d4 (11 bytes) 20:33:45.496 CNTRLR [Node 003] [+] [Binary Switch] currentValue: false [Endpoint 0] 20:33:45.497 SERIAL » [ACK] (0x06) 20:33:45.498 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 20:33:45.501 SERIAL » 0x010a0013050370050225e654 (12 bytes) 20:33:45.501 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 230 └─[ConfigurationCCGet] parameter #: 2 20:33:45.502 CNTRLR « [Node 003] received Binary Switch state: current value: false 20:33:45.502 CNTRLR [Node 003] [+] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] 20:33:45.507 SERIAL « [ACK] (0x06) 20:33:45.509 SERIAL « 0x0104011301e8 (6 bytes) 20:33:45.509 SERIAL » [ACK] (0x06) 20:33:45.510 DRIVER « [RES] [SendData] was sent: true 20:33:45.512 CNTRLR [Node 003] ConfigurationCC: Loading configuration parameters from device confi g 20:33:45.513 CNTRLR [Node 003] [+] [Configuration] isParamInformationFromConfig: false [internal] 20:33:45.513 CNTRLR [Node 003] [Configuration] 1: metadata updated 20:33:45.515 CNTRLR [Node 003] [Configuration] 2: metadata updated 20:33:45.516 CNTRLR [Node 003] [Configuration] 3: metadata updated 20:33:45.517 CNTRLR [Node 003] [Configuration] 10: metadata updated 20:33:45.518 CNTRLR [Node 003] [Configuration] 11: metadata updated 20:33:45.519 CNTRLR [Node 003] [Configuration] 12: metadata updated 20:33:45.520 CNTRLR [Node 003] [Configuration] 13: metadata updated 20:33:45.521 CNTRLR [Node 003] [Configuration] 14: metadata updated 20:33:45.521 CNTRLR [Node 003] [Configuration] 15: metadata updated 20:33:45.522 CNTRLR [Node 003] [Configuration] 20: metadata updated 20:33:45.523 CNTRLR [Node 003] [Configuration] 21: metadata updated 20:33:45.523 CNTRLR [Node 003] [Configuration] 22: metadata updated 20:33:45.524 CNTRLR [Node 003] [Configuration] 23: metadata updated 20:33:45.525 CNTRLR [Node 003] [Configuration] 24: metadata updated 20:33:45.525 CNTRLR [Node 003] [Configuration] 30: metadata updated 20:33:45.526 CNTRLR [Node 003] [Configuration] 31: metadata updated 20:33:45.526 CNTRLR [Node 003] [Configuration] 32: metadata updated 20:33:45.527 CNTRLR [Node 003] [Configuration] 40: metadata updated 20:33:45.527 CNTRLR [Node 003] [Configuration] 41: metadata updated 20:33:45.528 CNTRLR [Node 003] [Configuration] 42: metadata updated 20:33:45.528 CNTRLR [Node 003] [Configuration] 43: metadata updated 20:33:45.529 CNTRLR [Node 003] [Configuration] 50: metadata updated 20:33:45.529 CNTRLR [Node 003] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 20:33:45.529 CNTRLR » [Node 003] querying parameter #1 value... 20:33:45.533 SERIAL « 0x01070013e60000020f (9 bytes) 20:33:45.533 SERIAL » [ACK] (0x06) 20:33:45.538 DRIVER « [REQ] [SendData] callback id: 230 transmit status: OK 20:33:45.547 SERIAL « 0x010c000400050670060202000684 (14 bytes) 20:33:45.547 CNTRLR [Node 005] [+] [Configuration] 2: 6 20:33:45.548 SERIAL » [ACK] (0x06) 20:33:45.549 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 2 value: 6 20:33:45.550 SERIAL » 0x010a0013060370050225e756 (12 bytes) 20:33:45.551 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 231 └─[ConfigurationCCGet] parameter #: 2 20:33:45.551 CNTRLR « [Node 005] parameter #2 has value: 6 20:33:45.551 CNTRLR » [Node 005] querying parameter #3 value... 20:33:45.552 SERIAL « [ACK] (0x06) 20:33:45.555 SERIAL « 0x0104011301e8 (6 bytes) 20:33:45.556 SERIAL » [ACK] (0x06) 20:33:45.556 DRIVER « [RES] [SendData] was sent: true 20:33:45.571 SERIAL « 0x01070013e70000020e (9 bytes) 20:33:45.571 SERIAL » [ACK] (0x06) 20:33:45.571 DRIVER « [REQ] [SendData] callback id: 231 transmit status: OK 20:33:45.581 SERIAL « 0x010c000400060670060202000687 (14 bytes) 20:33:45.581 CNTRLR [Node 006] [+] [Configuration] 2: 6 20:33:45.582 SERIAL » [ACK] (0x06) 20:33:45.582 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 2 value: 6 20:33:45.583 SERIAL » 0x010a0013020332010025e819 (12 bytes) 20:33:45.584 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 232 └─[MeterCCGet] duration: kWh 20:33:45.584 CNTRLR « [Node 006] parameter #2 has value: 6 20:33:45.584 CNTRLR » [Node 006] querying parameter #3 value... 20:33:45.586 SERIAL « [ACK] (0x06) 20:33:45.589 SERIAL « 0x0104011301e8 (6 bytes) 20:33:45.589 SERIAL » [ACK] (0x06) 20:33:45.589 DRIVER « [RES] [SendData] was sent: true 20:33:45.608 SERIAL « 0x01070013e800000201 (9 bytes) 20:33:45.609 SERIAL » [ACK] (0x06) 20:33:45.609 DRIVER « [REQ] [SendData] callback id: 232 transmit status: OK 20:33:45.639 SERIAL « 0x0114000400020e3202214400000000011100000000a6 (22 bytes) 20:33:45.640 CNTRLR [Node 002] [Meter] value[65537]: metadata updated [Endpoint 0] 20:33:45.641 CNTRLR [Node 002] [Meter] previousValue[65537]: metadata updated [Endpoint 0] 20:33:45.642 CNTRLR [Node 002] [Meter] deltaTime[65537]: metadata updated [Endpoint 0] 20:33:45.642 CNTRLR [Node 002] [+] [Meter] value[65537]: 0 [Endpoint 0] 20:33:45.643 CNTRLR [Node 002] [+] [Meter] previousValue[65537]: 0 [Endpoint 0] 20:33:45.644 CNTRLR [Node 002] [+] [Meter] deltaTime[65537]: 273 [Endpoint 0] 20:33:45.644 SERIAL » [ACK] (0x06) 20:33:45.645 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 0 time delta: 273 seconds prev. value: 0 20:33:45.649 SERIAL » 0x010a0013130386138625e929 (12 bytes) 20:33:45.649 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 233 └─[VersionCCCommandClassGet] CC: Version 20:33:45.650 CNTRLR » [Node 002] querying meter value (type = Electric, scale = W)... 20:33:45.655 SERIAL « [ACK] (0x06) 20:33:45.657 SERIAL « 0x0104011301e8 (6 bytes) 20:33:45.657 SERIAL » [ACK] (0x06) 20:33:45.658 DRIVER « [RES] [SendData] was sent: true 20:33:45.796 SERIAL « 0x01070013e900000e0c (9 bytes) 20:33:45.797 SERIAL » [ACK] (0x06) 20:33:45.797 DRIVER « [REQ] [SendData] callback id: 233 transmit status: OK 20:33:45.832 SERIAL « 0x010c0004001c063105042202d72a (14 bytes) 20:33:45.833 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:33:45.834 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 86.5 => 72.7 [Endpoint 0] 20:33:45.835 SERIAL » [ACK] (0x06) 20:33:45.836 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 72.7 20:33:45.925 SERIAL « 0x010a000400130486148602f0 (12 bytes) 20:33:45.926 SERIAL » [ACK] (0x06) 20:33:45.927 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 2 20:33:45.930 SERIAL » 0x010900131202250225ea1d (11 bytes) 20:33:45.930 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 234 └─[BinarySwitchCCGet] 20:33:45.931 CNTRLR [Node 019] supports CC Version (0x86) in version 2 20:33:45.931 CNTRLR [Node 019] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 20:33:45.931 CNTRLR [Node 019] trying to load device config 20:33:45.932 SERIAL « [ACK] (0x06) 20:33:45.938 CNTRLR [Node 019] device config loaded 20:33:45.939 SERIAL « 0x0104011301e8 (6 bytes) 20:33:45.940 SERIAL » [ACK] (0x06) 20:33:45.940 DRIVER « [RES] [SendData] was sent: true 20:33:45.941 CNTRLR [Node 019] ZWavePlusCC: doing a complete interview... 20:33:45.941 CNTRLR » [Node 019] querying Z-Wave+ information... 20:33:46.054 SERIAL « 0x01070013ea00000c0d (9 bytes) 20:33:46.055 SERIAL » [ACK] (0x06) 20:33:46.055 DRIVER « [REQ] [SendData] callback id: 234 transmit status: OK 20:33:46.064 SERIAL « 0x010900040012032503ff3a (11 bytes) 20:33:46.065 CNTRLR [Node 018] [+] [Binary Switch] currentValue: true [Endpoint 0] 20:33:46.066 SERIAL » [ACK] (0x06) 20:33:46.068 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: true 20:33:46.071 SERIAL » 0x0109001314025e0125eb62 (11 bytes) 20:33:46.071 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 235 └─[ZWavePlusCCGet] 20:33:46.072 CNTRLR « [Node 018] received Binary Switch state: current value: true 20:33:46.072 CNTRLR [Node 018] [+] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] 20:33:46.073 CNTRLR [Node 018] ConfigurationCC: Loading configuration parameters from device confi g 20:33:46.074 CNTRLR [Node 018] [+] [Configuration] isParamInformationFromConfig: false [internal] 20:33:46.074 CNTRLR [Node 018] [Configuration] 1: metadata updated 20:33:46.075 CNTRLR [Node 018] [Configuration] 2: metadata updated 20:33:46.076 CNTRLR [Node 018] [Configuration] 3: metadata updated 20:33:46.077 CNTRLR [Node 018] [Configuration] 4: metadata updated 20:33:46.078 CNTRLR [Node 018] [Configuration] 5: metadata updated 20:33:46.079 CNTRLR [Node 018] [Configuration] 6: metadata updated 20:33:46.080 CNTRLR [Node 018] [Configuration] 7: metadata updated 20:33:46.081 CNTRLR [Node 018] [Configuration] 8: metadata updated 20:33:46.082 CNTRLR [Node 018] [Configuration] 9: metadata updated 20:33:46.082 CNTRLR [Node 018] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 20:33:46.083 CNTRLR » [Node 018] querying parameter #1 value... 20:33:46.088 SERIAL « [ACK] (0x06) 20:33:46.089 SERIAL « 0x0104011301e8 (6 bytes) 20:33:46.089 SERIAL » [ACK] (0x06) 20:33:46.090 DRIVER « [RES] [SendData] was sent: true 20:33:46.099 SERIAL « 0x01070013eb00000202 (9 bytes) 20:33:46.099 SERIAL » [ACK] (0x06) 20:33:46.101 DRIVER « [REQ] [SendData] callback id: 235 transmit status: OK 20:33:46.124 SERIAL « 0x010f00040014095e0201050007000700b1 (17 bytes) 20:33:46.125 CNTRLR [Node 020] [+] [Z-Wave Plus Info] zwavePlusVersion: 1 [Endpoint 0] 20:33:46.125 CNTRLR [Node 020] [+] [Z-Wave Plus Info] nodeType: 0 [Endpoint 0] 20:33:46.125 CNTRLR [Node 020] [+] [Z-Wave Plus Info] roleType: 5 [Endpoint 0] 20:33:46.126 CNTRLR [Node 020] [+] [Z-Wave Plus Info] installerIcon: 1792 [Endpoint 0] 20:33:46.126 CNTRLR [Node 020] [+] [Z-Wave Plus Info] userIcon: 1792 [Endpoint 0] 20:33:46.126 SERIAL » [ACK] (0x06) 20:33:46.127 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[ZWavePlusCCReport] version: 1 node type: Node role type: AlwaysOnSlave icon (mgmt.): 0x0700 icon (user): 0x0700 20:33:46.128 SERIAL » 0x010a0013150386137025ecdc (12 bytes) 20:33:46.129 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 236 └─[VersionCCCommandClassGet] CC: Configuration 20:33:46.129 CNTRLR « [Node 020] received response for Z-Wave+ information: Z-Wave+ version: 1 role type: AlwaysOnSlave node type: Node installer icon: 0x0700 user icon: 0x0700 20:33:46.129 CNTRLR [Node 020] [+] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue 20:33:46.133 SERIAL « [ACK] (0x06) 20:33:46.135 SERIAL « 0x0104011301e8 (6 bytes) 20:33:46.135 SERIAL » [ACK] (0x06) 20:33:46.135 DRIVER « [RES] [SendData] was sent: true 20:33:46.136 CNTRLR [Node 020] BinarySwitchCC: doing a complete interview... 20:33:46.136 CNTRLR » [Node 020] querying Binary Switch state... 20:33:47.553 SERIAL « 0x01070013ec00008e89 (9 bytes) 20:33:47.554 SERIAL » [ACK] (0x06) 20:33:47.554 DRIVER « [REQ] [SendData] callback id: 236 transmit status: OK 20:33:47.629 SERIAL « 0x010a00040015048614700103 (12 bytes) 20:33:47.630 SERIAL » [ACK] (0x06) 20:33:47.631 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Configuration version: 1 20:33:47.633 SERIAL » 0x010a0013160386137025edde (12 bytes) 20:33:47.634 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 237 └─[VersionCCCommandClassGet] CC: Configuration 20:33:47.634 CNTRLR [Node 021] supports CC Configuration (0x70) in version 1 20:33:47.634 CNTRLR » [Node 021] querying the CC version for Notification (0x71)... 20:33:47.637 SERIAL « [ACK] (0x06) 20:33:47.639 SERIAL « 0x0104011301e8 (6 bytes) 20:33:47.640 SERIAL » [ACK] (0x06) 20:33:47.640 DRIVER « [RES] [SendData] was sent: true 20:33:49.064 SERIAL « 0x01070013ed00008f89 (9 bytes) 20:33:49.064 SERIAL » [ACK] (0x06) 20:33:49.065 DRIVER « [REQ] [SendData] callback id: 237 transmit status: OK 20:33:49.141 SERIAL « 0x010a00040016048614700100 (12 bytes) 20:33:49.142 SERIAL » [ACK] (0x06) 20:33:49.143 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Configuration version: 1 20:33:49.145 SERIAL » 0x010a0013170386137025eedc (12 bytes) 20:33:49.146 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 238 └─[VersionCCCommandClassGet] CC: Configuration 20:33:49.146 CNTRLR [Node 022] supports CC Configuration (0x70) in version 1 20:33:49.146 CNTRLR » [Node 022] querying the CC version for Notification (0x71)... 20:33:49.147 SERIAL « [ACK] (0x06) 20:33:49.151 SERIAL « 0x0104011301e8 (6 bytes) 20:33:49.151 SERIAL » [ACK] (0x06) 20:33:49.152 DRIVER « [RES] [SendData] was sent: true 20:33:50.647 SERIAL « 0x01070013ee00009693 (9 bytes) 20:33:50.647 SERIAL » [ACK] (0x06) 20:33:50.648 DRIVER « [REQ] [SendData] callback id: 238 transmit status: OK 20:33:50.723 SERIAL « 0x010a00040017048614700101 (12 bytes) 20:33:50.723 SERIAL » [ACK] (0x06) 20:33:50.724 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Configuration version: 1 20:33:50.727 SERIAL » 0x010a0013180386137025efd2 (12 bytes) 20:33:50.727 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 239 └─[VersionCCCommandClassGet] CC: Configuration 20:33:50.727 CNTRLR [Node 023] supports CC Configuration (0x70) in version 1 20:33:50.727 CNTRLR » [Node 023] querying the CC version for Notification (0x71)... 20:33:50.730 SERIAL « [ACK] (0x06) 20:33:50.733 SERIAL « 0x0104011301e8 (6 bytes) 20:33:50.733 SERIAL » [ACK] (0x06) 20:33:50.734 DRIVER « [RES] [SendData] was sent: true 20:33:50.891 SERIAL « 0x010c0004001c0631050422035ba7 (14 bytes) 20:33:50.892 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:33:50.893 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 72.7 => 85.9 [Endpoint 0] 20:33:50.893 SERIAL » [ACK] (0x06) 20:33:50.894 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 85.9 20:33:52.344 SERIAL « 0x01070013ef0000a2a6 (9 bytes) 20:33:52.345 SERIAL » [ACK] (0x06) 20:33:52.345 DRIVER « [REQ] [SendData] callback id: 239 transmit status: OK 20:33:52.425 SERIAL « 0x010a0004001804861470010e (12 bytes) 20:33:52.425 SERIAL » [ACK] (0x06) 20:33:52.426 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Configuration version: 1 20:33:52.429 SERIAL » 0x010a00131a0386138625f039 (12 bytes) 20:33:52.429 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 240 └─[VersionCCCommandClassGet] CC: Version 20:33:52.430 CNTRLR [Node 024] supports CC Configuration (0x70) in version 1 20:33:52.430 CNTRLR » [Node 024] querying the CC version for Notification (0x71)... 20:33:52.432 SERIAL « [ACK] (0x06) 20:33:52.435 SERIAL « 0x0104011301e8 (6 bytes) 20:33:52.435 SERIAL » [ACK] (0x06) 20:33:52.436 DRIVER « [RES] [SendData] was sent: true 20:33:52.540 SERIAL « 0x01070013f000000b10 (9 bytes) 20:33:52.540 SERIAL » [ACK] (0x06) 20:33:52.541 DRIVER « [REQ] [SendData] callback id: 240 transmit status: OK 20:33:52.611 SERIAL « 0x010a0004001a0486148602f9 (12 bytes) 20:33:52.612 SERIAL » [ACK] (0x06) 20:33:52.612 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 2 20:33:52.615 SERIAL » 0x010a00131c0386138625f13e (12 bytes) 20:33:52.615 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 241 └─[VersionCCCommandClassGet] CC: Version 20:33:52.616 CNTRLR [Node 026] supports CC Version (0x86) in version 2 20:33:52.616 CNTRLR [Node 026] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 20:33:52.616 CNTRLR [Node 026] trying to load device config 20:33:52.618 SERIAL « [ACK] (0x06) 20:33:52.632 CNTRLR [Node 026] device config loaded 20:33:52.633 SERIAL « 0x0104011301e8 (6 bytes) 20:33:52.633 SERIAL » [ACK] (0x06) 20:33:52.637 DRIVER « [RES] [SendData] was sent: true 20:33:52.639 CNTRLR [Node 026] ZWavePlusCC: doing a complete interview... 20:33:52.640 CNTRLR » [Node 026] querying Z-Wave+ information... 20:33:52.699 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:33:52.700 CNTRLR [Node 005] [Meter] previousValue[66049]: metadata updated [Endpoint 0] 20:33:52.700 CNTRLR [Node 005] [Meter] deltaTime[66049]: metadata updated [Endpoint 0] 20:33:52.701 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:33:52.702 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:33:52.703 SERIAL » [ACK] (0x06) 20:33:52.704 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:33:52.731 SERIAL « 0x01070013f100000c16 (9 bytes) 20:33:52.731 SERIAL » [ACK] (0x06) 20:33:52.732 DRIVER « [REQ] [SendData] callback id: 241 transmit status: OK 20:33:52.741 SERIAL « 0x010a0004001c0486148602ff (12 bytes) 20:33:52.742 SERIAL » [ACK] (0x06) 20:33:52.742 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 2 20:33:52.745 SERIAL » 0x010a0013030370050125f245 (12 bytes) 20:33:52.746 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 242 └─[ConfigurationCCGet] parameter #: 1 20:33:52.746 CNTRLR [Node 028] supports CC Version (0x86) in version 2 20:33:52.746 CNTRLR [Node 028] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 20:33:52.746 CNTRLR [Node 028] trying to load device config 20:33:52.749 SERIAL « [ACK] (0x06) 20:33:52.762 CNTRLR [Node 028] device config loaded 20:33:52.763 CNTRLR [Node 028] ZWavePlusCC: doing a complete interview... 20:33:52.763 CNTRLR » [Node 028] querying Z-Wave+ information... 20:33:52.764 SERIAL « 0x0104011301e8 (6 bytes) 20:33:52.765 SERIAL » [ACK] (0x06) 20:33:52.765 DRIVER « [RES] [SendData] was sent: true 20:33:52.770 SERIAL « 0x01070013f20000031a (9 bytes) 20:33:52.770 SERIAL » [ACK] (0x06) 20:33:52.771 DRIVER « [REQ] [SendData] callback id: 242 transmit status: OK 20:33:52.783 SERIAL « 0x010b0004000305700601010080 (13 bytes) 20:33:52.784 CNTRLR [Node 003] [+] [Configuration] 1: 0 20:33:52.784 SERIAL » [ACK] (0x06) 20:33:52.785 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 0 20:33:52.786 SERIAL » 0x010a0013050370050325f340 (12 bytes) 20:33:52.787 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 243 └─[ConfigurationCCGet] parameter #: 3 20:33:52.787 CNTRLR « [Node 003] parameter #1 has value: 0 20:33:52.787 CNTRLR » [Node 003] querying parameter #2 value... 20:33:52.788 SERIAL « [ACK] (0x06) 20:33:52.792 SERIAL « 0x0104011301e8 (6 bytes) 20:33:52.792 SERIAL » [ACK] (0x06) 20:33:52.793 DRIVER « [RES] [SendData] was sent: true 20:33:52.807 SERIAL « 0x01070013f30000021a (9 bytes) 20:33:52.808 SERIAL » [ACK] (0x06) 20:33:52.808 DRIVER « [REQ] [SendData] callback id: 243 transmit status: OK 20:33:52.817 SERIAL « 0x010c000400050670060302051492 (14 bytes) 20:33:52.818 CNTRLR [Node 005] [+] [Configuration] 3: 1300 20:33:52.819 SERIAL » [ACK] (0x06) 20:33:52.819 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 2 value: 1300 20:33:52.821 SERIAL » 0x010a0013060370050325f444 (12 bytes) 20:33:52.821 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 244 └─[ConfigurationCCGet] parameter #: 3 20:33:52.821 CNTRLR « [Node 005] parameter #3 has value: 1300 20:33:52.821 CNTRLR » [Node 005] querying parameter #4 value... 20:33:52.823 SERIAL « [ACK] (0x06) 20:33:52.826 SERIAL « 0x0104011301e8 (6 bytes) 20:33:52.826 SERIAL » [ACK] (0x06) 20:33:52.827 DRIVER « [RES] [SendData] was sent: true 20:33:52.841 SERIAL « 0x01070013f40000021d (9 bytes) 20:33:52.842 SERIAL » [ACK] (0x06) 20:33:52.842 DRIVER « [REQ] [SendData] callback id: 244 transmit status: OK 20:33:52.851 SERIAL « 0x010c000400060670060302051491 (14 bytes) 20:33:52.853 CNTRLR [Node 006] [+] [Configuration] 3: 1300 20:33:52.854 SERIAL » [ACK] (0x06) 20:33:52.854 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 2 value: 1300 20:33:52.857 SERIAL » 0x010a0013020332011025f514 (12 bytes) 20:33:52.858 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 245 └─[MeterCCGet] duration: W 20:33:52.858 CNTRLR « [Node 006] parameter #3 has value: 1300 20:33:52.858 CNTRLR » [Node 006] querying parameter #4 value... 20:33:52.861 SERIAL « [ACK] (0x06) 20:33:52.863 SERIAL « 0x0104011301e8 (6 bytes) 20:33:52.863 SERIAL » [ACK] (0x06) 20:33:52.864 DRIVER « [RES] [SendData] was sent: true 20:33:52.883 SERIAL « 0x01070013f50000021c (9 bytes) 20:33:52.883 SERIAL » [ACK] (0x06) 20:33:52.884 DRIVER « [REQ] [SendData] callback id: 245 transmit status: OK 20:33:52.918 SERIAL « 0x0114000400020e3202213400000000000000000000c6 (22 bytes) 20:33:52.918 CNTRLR [Node 002] [Meter] value[66049]: metadata updated [Endpoint 0] 20:33:52.919 CNTRLR [Node 002] [Meter] previousValue[66049]: metadata updated [Endpoint 0] 20:33:52.920 CNTRLR [Node 002] [Meter] deltaTime[66049]: metadata updated [Endpoint 0] 20:33:52.920 CNTRLR [Node 002] [+] [Meter] value[66049]: 0 [Endpoint 0] 20:33:52.921 CNTRLR [Node 002] [+] [Meter] deltaTime[66049]: 0 [Endpoint 0] 20:33:52.921 SERIAL » [ACK] (0x06) 20:33:52.922 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:33:52.925 SERIAL » 0x0109001313025e0125f678 (11 bytes) 20:33:52.926 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 246 └─[ZWavePlusCCGet] 20:33:52.926 CNTRLR » [Node 002] querying meter value (type = Electric, scale = V)... 20:33:52.930 SERIAL « [ACK] (0x06) 20:33:52.931 SERIAL « 0x0104011301e8 (6 bytes) 20:33:52.931 SERIAL » [ACK] (0x06) 20:33:52.932 DRIVER « [RES] [SendData] was sent: true 20:33:53.071 SERIAL « 0x01070013f600000f12 (9 bytes) 20:33:53.072 SERIAL » [ACK] (0x06) 20:33:53.072 DRIVER « [REQ] [SendData] callback id: 246 transmit status: OK 20:33:53.203 SERIAL « 0x010f00040013095e0201050007000700b6 (17 bytes) 20:33:53.204 CNTRLR [Node 019] [+] [Z-Wave Plus Info] zwavePlusVersion: 1 [Endpoint 0] 20:33:53.205 CNTRLR [Node 019] [+] [Z-Wave Plus Info] nodeType: 0 [Endpoint 0] 20:33:53.205 CNTRLR [Node 019] [+] [Z-Wave Plus Info] roleType: 5 [Endpoint 0] 20:33:53.206 CNTRLR [Node 019] [+] [Z-Wave Plus Info] installerIcon: 1792 [Endpoint 0] 20:33:53.206 CNTRLR [Node 019] [+] [Z-Wave Plus Info] userIcon: 1792 [Endpoint 0] 20:33:53.207 SERIAL » [ACK] (0x06) 20:33:53.208 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ZWavePlusCCReport] version: 1 node type: Node role type: AlwaysOnSlave icon (mgmt.): 0x0700 icon (user): 0x0700 20:33:53.211 SERIAL » 0x010a0013120370050125f751 (12 bytes) 20:33:53.212 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 247 └─[ConfigurationCCGet] parameter #: 1 20:33:53.212 CNTRLR « [Node 019] received response for Z-Wave+ information: Z-Wave+ version: 1 role type: AlwaysOnSlave node type: Node installer icon: 0x0700 user icon: 0x0700 20:33:53.212 CNTRLR [Node 019] [+] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue 20:33:53.222 SERIAL « [ACK] (0x06) 20:33:53.227 SERIAL « 0x0104011301e8 (6 bytes) 20:33:53.227 SERIAL » [ACK] (0x06) 20:33:53.228 DRIVER « [RES] [SendData] was sent: true 20:33:53.229 CNTRLR [Node 019] BinarySwitchCC: doing a complete interview... 20:33:53.229 CNTRLR » [Node 019] querying Binary Switch state... 20:33:53.334 SERIAL « 0x01070013f700000c10 (9 bytes) 20:33:53.335 SERIAL » [ACK] (0x06) 20:33:53.335 DRIVER « [REQ] [SendData] callback id: 247 transmit status: OK 20:33:53.345 SERIAL « 0x010c00040012067006010202d044 (14 bytes) 20:33:53.346 CNTRLR [Node 018] [+] [Configuration] 1: 720 20:33:53.347 SERIAL » [ACK] (0x06) 20:33:53.348 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 2 value: 720 20:33:53.350 SERIAL » 0x010900131402250225f809 (11 bytes) 20:33:53.351 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 248 └─[BinarySwitchCCGet] 20:33:53.351 CNTRLR « [Node 018] parameter #1 has value: 720 20:33:53.351 CNTRLR » [Node 018] querying parameter #2 value... 20:33:53.354 SERIAL « [ACK] (0x06) 20:33:53.356 SERIAL « 0x0104011301e8 (6 bytes) 20:33:53.357 SERIAL » [ACK] (0x06) 20:33:53.358 DRIVER « [RES] [SendData] was sent: true 20:33:53.375 SERIAL « 0x01070013f800000211 (9 bytes) 20:33:53.376 SERIAL » [ACK] (0x06) 20:33:53.376 DRIVER « [REQ] [SendData] callback id: 248 transmit status: OK 20:33:53.405 SERIAL « 0x01090004001403250300c3 (11 bytes) 20:33:53.406 CNTRLR [Node 020] [+] [Binary Switch] currentValue: false [Endpoint 0] 20:33:53.406 SERIAL » [ACK] (0x06) 20:33:53.407 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 20:33:53.410 SERIAL » 0x010a0013150386137125f9c8 (12 bytes) 20:33:53.410 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 249 └─[VersionCCCommandClassGet] CC: Notification 20:33:53.411 CNTRLR « [Node 020] received Binary Switch state: current value: false 20:33:53.411 CNTRLR [Node 020] [+] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] 20:33:53.412 CNTRLR [Node 020] MeterCC: doing a complete interview... 20:33:53.412 CNTRLR » [Node 020] querying meter support... 20:33:53.416 SERIAL « [ACK] (0x06) 20:33:53.418 SERIAL « 0x0104011301e8 (6 bytes) 20:33:53.418 SERIAL » [ACK] (0x06) 20:33:53.419 DRIVER « [RES] [SendData] was sent: true 20:33:54.853 SERIAL « 0x01070013f900009082 (9 bytes) 20:33:54.853 SERIAL » [ACK] (0x06) 20:33:54.854 DRIVER « [REQ] [SendData] callback id: 249 transmit status: OK 20:33:54.938 SERIAL « 0x010a0004001504861471080b (12 bytes) 20:33:54.938 SERIAL » [ACK] (0x06) 20:33:54.939 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Notification version: 8 20:33:54.942 SERIAL » 0x010a0013160386137125fac8 (12 bytes) 20:33:54.942 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 250 └─[VersionCCCommandClassGet] CC: Notification 20:33:54.942 CNTRLR [Node 021] supports CC Notification (0x71) in version 8 20:33:54.942 CNTRLR [Node 021] skipping query for Powerlevel (0x73) because max implemented vers ion is 0 20:33:54.943 CNTRLR [Node 021] skipping query for Security (0x98) because max implemented versio n is 1 20:33:54.943 CNTRLR [Node 021] skipping query for Security 2 (0x9f) because max implemented vers ion is 0 20:33:54.943 CNTRLR [Node 021] skipping query for Transport Service (0x55) because max implement ed version is 0 20:33:54.943 CNTRLR [Node 021] skipping query for Supervision (0x6c) because max implemented ver sion is 1 20:33:54.943 CNTRLR » [Node 021] querying the CC version for Firmware Update Meta Data (0x7a)... 20:33:54.946 SERIAL « [ACK] (0x06) 20:33:54.948 SERIAL « 0x0104011301e8 (6 bytes) 20:33:54.948 SERIAL » [ACK] (0x06) 20:33:54.949 DRIVER « [RES] [SendData] was sent: true 20:33:56.346 SERIAL « 0x01070013fa00008c9d (9 bytes) 20:33:56.347 SERIAL » [ACK] (0x06) 20:33:56.347 DRIVER « [REQ] [SendData] callback id: 250 transmit status: OK 20:33:56.427 SERIAL « 0x010a00040016048614710808 (12 bytes) 20:33:56.427 SERIAL » [ACK] (0x06) 20:33:56.428 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Notification version: 8 20:33:56.431 SERIAL » 0x010a0013170386137125fbc8 (12 bytes) 20:33:56.431 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 251 └─[VersionCCCommandClassGet] CC: Notification 20:33:56.431 CNTRLR [Node 022] supports CC Notification (0x71) in version 8 20:33:56.431 CNTRLR [Node 022] skipping query for Powerlevel (0x73) because max implemented vers ion is 0 20:33:56.431 CNTRLR [Node 022] skipping query for Security (0x98) because max implemented versio n is 1 20:33:56.431 CNTRLR [Node 022] skipping query for Security 2 (0x9f) because max implemented vers ion is 0 20:33:56.431 CNTRLR [Node 022] skipping query for Transport Service (0x55) because max implement ed version is 0 20:33:56.431 CNTRLR [Node 022] skipping query for Supervision (0x6c) because max implemented ver sion is 1 20:33:56.431 CNTRLR » [Node 022] querying the CC version for Firmware Update Meta Data (0x7a)... 20:33:56.433 SERIAL « [ACK] (0x06) 20:33:56.437 SERIAL « 0x0104011301e8 (6 bytes) 20:33:56.437 SERIAL » [ACK] (0x06) 20:33:56.437 DRIVER « [RES] [SendData] was sent: true 20:33:56.501 SERIAL « 0x01100004001a0a32022144000035e2000079 (18 bytes) 20:33:56.502 CNTRLR [Node 026] [Meter] value[65537]: metadata updated [Endpoint 0] 20:33:56.503 CNTRLR [Node 026] [Meter] previousValue[65537]: metadata updated [Endpoint 0] 20:33:56.504 CNTRLR [Node 026] [Meter] deltaTime[65537]: metadata updated [Endpoint 0] 20:33:56.504 CNTRLR [Node 026] [+] [Meter] value[65537]: 137.94 [Endpoint 0] 20:33:56.505 CNTRLR [Node 026] [+] [Meter] deltaTime[65537]: 0 [Endpoint 0] 20:33:56.505 SERIAL » [ACK] (0x06) 20:33:56.506 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 137.94 time delta: 0 seconds 20:33:57.972 SERIAL « 0x01070013fb00009a8a (9 bytes) 20:33:57.972 SERIAL » [ACK] (0x06) 20:33:57.973 DRIVER « [REQ] [SendData] callback id: 251 transmit status: OK 20:33:58.051 SERIAL « 0x010a00040017048614710809 (12 bytes) 20:33:58.051 SERIAL » [ACK] (0x06) 20:33:58.052 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Notification version: 8 20:33:58.055 SERIAL » 0x010a0013180386137125fcc0 (12 bytes) 20:33:58.055 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 252 └─[VersionCCCommandClassGet] CC: Notification 20:33:58.055 CNTRLR [Node 023] supports CC Notification (0x71) in version 8 20:33:58.055 CNTRLR [Node 023] skipping query for Powerlevel (0x73) because max implemented vers ion is 0 20:33:58.055 CNTRLR [Node 023] skipping query for Security (0x98) because max implemented versio n is 1 20:33:58.056 CNTRLR [Node 023] skipping query for Security 2 (0x9f) because max implemented vers ion is 0 20:33:58.056 CNTRLR [Node 023] skipping query for Transport Service (0x55) because max implement ed version is 0 20:33:58.056 CNTRLR [Node 023] skipping query for Supervision (0x6c) because max implemented ver sion is 1 20:33:58.056 CNTRLR » [Node 023] querying the CC version for Firmware Update Meta Data (0x7a)... 20:33:58.057 SERIAL « [ACK] (0x06) 20:33:58.061 SERIAL « 0x0104011301e8 (6 bytes) 20:33:58.061 SERIAL » [ACK] (0x06) 20:33:58.061 DRIVER « [RES] [SendData] was sent: true 20:33:59.484 SERIAL « 0x01070013fc00008f98 (9 bytes) 20:33:59.485 SERIAL » [ACK] (0x06) 20:33:59.485 DRIVER « [REQ] [SendData] callback id: 252 transmit status: OK 20:33:59.568 SERIAL « 0x010a00040018048614710806 (12 bytes) 20:33:59.569 SERIAL » [ACK] (0x06) 20:33:59.570 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Notification version: 8 20:33:59.572 SERIAL » 0x010900131a025e0125fd7a (11 bytes) 20:33:59.572 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 253 └─[ZWavePlusCCGet] 20:33:59.572 CNTRLR [Node 024] supports CC Notification (0x71) in version 8 20:33:59.573 CNTRLR [Node 024] skipping query for Powerlevel (0x73) because max implemented vers ion is 0 20:33:59.573 CNTRLR [Node 024] skipping query for Security (0x98) because max implemented versio n is 1 20:33:59.573 CNTRLR [Node 024] skipping query for Security 2 (0x9f) because max implemented vers ion is 0 20:33:59.573 CNTRLR [Node 024] skipping query for Transport Service (0x55) because max implement ed version is 0 20:33:59.573 CNTRLR [Node 024] skipping query for Supervision (0x6c) because max implemented ver sion is 1 20:33:59.573 CNTRLR » [Node 024] querying the CC version for Firmware Update Meta Data (0x7a)... 20:33:59.575 SERIAL « [ACK] (0x06) 20:33:59.578 SERIAL « 0x0104011301e8 (6 bytes) 20:33:59.578 SERIAL » [ACK] (0x06) 20:33:59.578 DRIVER « [RES] [SendData] was sent: true 20:33:59.680 SERIAL « 0x01070013fd00000a1c (9 bytes) 20:33:59.680 SERIAL » [ACK] (0x06) 20:33:59.681 DRIVER « [REQ] [SendData] callback id: 253 transmit status: OK 20:33:59.752 SERIAL « 0x010f0004001a095e0201050007000700bf (17 bytes) 20:33:59.753 CNTRLR [Node 026] [+] [Z-Wave Plus Info] zwavePlusVersion: 1 [Endpoint 0] 20:33:59.753 CNTRLR [Node 026] [+] [Z-Wave Plus Info] nodeType: 0 [Endpoint 0] 20:33:59.754 CNTRLR [Node 026] [+] [Z-Wave Plus Info] roleType: 5 [Endpoint 0] 20:33:59.754 CNTRLR [Node 026] [+] [Z-Wave Plus Info] installerIcon: 1792 [Endpoint 0] 20:33:59.755 CNTRLR [Node 026] [+] [Z-Wave Plus Info] userIcon: 1792 [Endpoint 0] 20:33:59.755 SERIAL » [ACK] (0x06) 20:33:59.759 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ZWavePlusCCReport] version: 1 node type: Node role type: AlwaysOnSlave icon (mgmt.): 0x0700 icon (user): 0x0700 20:33:59.762 SERIAL » 0x010900131c025e0125fe7f (11 bytes) 20:33:59.762 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 254 └─[ZWavePlusCCGet] 20:33:59.762 CNTRLR « [Node 026] received response for Z-Wave+ information: Z-Wave+ version: 1 role type: AlwaysOnSlave node type: Node installer icon: 0x0700 user icon: 0x0700 20:33:59.763 CNTRLR [Node 026] [+] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue 20:33:59.769 SERIAL « [ACK] (0x06) 20:33:59.772 SERIAL « 0x0104011301e8 (6 bytes) 20:33:59.772 SERIAL » [ACK] (0x06) 20:33:59.773 DRIVER « [RES] [SendData] was sent: true 20:33:59.776 CNTRLR [Node 026] BinarySwitchCC: doing a complete interview... 20:33:59.776 CNTRLR » [Node 026] querying Binary Switch state... 20:33:59.810 SERIAL « 0x010c0004001c063105042202d528 (14 bytes) 20:33:59.811 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:33:59.811 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 85.9 => 72.5 [Endpoint 0] 20:33:59.812 SERIAL » [ACK] (0x06) 20:33:59.813 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 72.5 20:33:59.840 SERIAL « 0x01070013fe0000081d (9 bytes) 20:33:59.841 SERIAL » [ACK] (0x06) 20:33:59.841 DRIVER « [REQ] [SendData] callback id: 254 transmit status: OK 20:33:59.851 SERIAL « 0x010f0004001c095e0201050007000700b9 (17 bytes) 20:33:59.852 CNTRLR [Node 028] [+] [Z-Wave Plus Info] zwavePlusVersion: 1 [Endpoint 0] 20:33:59.852 CNTRLR [Node 028] [+] [Z-Wave Plus Info] nodeType: 0 [Endpoint 0] 20:33:59.853 CNTRLR [Node 028] [+] [Z-Wave Plus Info] roleType: 5 [Endpoint 0] 20:33:59.853 CNTRLR [Node 028] [+] [Z-Wave Plus Info] installerIcon: 1792 [Endpoint 0] 20:33:59.854 CNTRLR [Node 028] [+] [Z-Wave Plus Info] userIcon: 1792 [Endpoint 0] 20:33:59.854 SERIAL » [ACK] (0x06) 20:33:59.855 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ZWavePlusCCReport] version: 1 node type: Node role type: AlwaysOnSlave icon (mgmt.): 0x0700 icon (user): 0x0700 20:33:59.858 SERIAL » 0x010a0013030370050225ff4b (12 bytes) 20:33:59.858 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 255 └─[ConfigurationCCGet] parameter #: 2 20:33:59.859 CNTRLR « [Node 028] received response for Z-Wave+ information: Z-Wave+ version: 1 role type: AlwaysOnSlave node type: Node installer icon: 0x0700 user icon: 0x0700 20:33:59.859 CNTRLR [Node 028] [+] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue 20:33:59.860 CNTRLR [Node 028] BinarySwitchCC: doing a complete interview... 20:33:59.860 CNTRLR » [Node 028] querying Binary Switch state... 20:33:59.863 SERIAL « [ACK] (0x06) 20:33:59.865 SERIAL « 0x0104011301e8 (6 bytes) 20:33:59.865 SERIAL » [ACK] (0x06) 20:33:59.866 DRIVER « [RES] [SendData] was sent: true 20:33:59.883 SERIAL « 0x01070013ff00000216 (9 bytes) 20:33:59.884 SERIAL » [ACK] (0x06) 20:33:59.884 DRIVER « [REQ] [SendData] callback id: 255 transmit status: OK 20:33:59.951 SERIAL « 0x010b0004000305700602010182 (13 bytes) 20:33:59.955 CNTRLR [Node 003] [+] [Configuration] 2: 1 20:33:59.956 SERIAL » [ACK] (0x06) 20:33:59.957 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 1 20:33:59.960 SERIAL » 0x010a001305037005042501b5 (12 bytes) 20:33:59.960 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 1 └─[ConfigurationCCGet] parameter #: 4 20:33:59.960 CNTRLR « [Node 003] parameter #2 has value: 1 20:33:59.961 CNTRLR » [Node 003] querying parameter #3 value... 20:33:59.964 SERIAL « [ACK] (0x06) 20:33:59.965 SERIAL « 0x0104011301e8 (6 bytes) 20:33:59.966 SERIAL » [ACK] (0x06) 20:33:59.967 DRIVER « [RES] [SendData] was sent: true 20:33:59.980 SERIAL « 0x0107001301000002e8 (9 bytes) 20:33:59.981 SERIAL » [ACK] (0x06) 20:33:59.981 DRIVER « [REQ] [SendData] callback id: 1 transmit status: OK 20:33:59.991 SERIAL « 0x010c0004000506700604022710b3 (14 bytes) 20:33:59.992 CNTRLR [Node 005] [+] [Configuration] 4: 10000 20:33:59.993 SERIAL » [ACK] (0x06) 20:33:59.994 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 2 value: 10000 20:33:59.996 SERIAL » 0x010a001306037005042502b5 (12 bytes) 20:33:59.997 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 2 └─[ConfigurationCCGet] parameter #: 4 20:33:59.997 CNTRLR « [Node 005] parameter #4 has value: 10000 20:33:59.997 CNTRLR » [Node 005] querying parameter #5 value... 20:34:00.000 SERIAL « [ACK] (0x06) 20:34:00.003 SERIAL « 0x0104011301e8 (6 bytes) 20:34:00.003 SERIAL » [ACK] (0x06) 20:34:00.004 DRIVER « [RES] [SendData] was sent: true 20:34:00.017 SERIAL « 0x0107001302000002eb (9 bytes) 20:34:00.017 SERIAL » [ACK] (0x06) 20:34:00.018 DRIVER « [REQ] [SendData] callback id: 2 transmit status: OK 20:34:00.027 SERIAL « 0x010c0004000606700604022710b0 (14 bytes) 20:34:00.028 CNTRLR [Node 006] [+] [Configuration] 4: 10000 20:34:00.028 SERIAL » [ACK] (0x06) 20:34:00.029 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 2 value: 10000 20:34:00.030 SERIAL » 0x010a001302033201202503d2 (12 bytes) 20:34:00.030 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 3 └─[MeterCCGet] duration: V 20:34:00.030 CNTRLR « [Node 006] parameter #4 has value: 10000 20:34:00.031 CNTRLR » [Node 006] querying parameter #5 value... 20:34:00.032 SERIAL « [ACK] (0x06) 20:34:00.035 SERIAL « 0x0104011301e8 (6 bytes) 20:34:00.036 SERIAL » [ACK] (0x06) 20:34:00.036 DRIVER « [RES] [SendData] was sent: true 20:34:00.055 SERIAL « 0x0107001303000002ea (9 bytes) 20:34:00.055 SERIAL » [ACK] (0x06) 20:34:00.056 DRIVER « [REQ] [SendData] callback id: 3 transmit status: OK 20:34:00.085 SERIAL « 0x0110000400020a3202a1220913000000004a (18 bytes) 20:34:00.086 CNTRLR [Node 002] [Meter] value[66561]: metadata updated [Endpoint 0] 20:34:00.087 CNTRLR [Node 002] [Meter] previousValue[66561]: metadata updated [Endpoint 0] 20:34:00.088 CNTRLR [Node 002] [Meter] deltaTime[66561]: metadata updated [Endpoint 0] 20:34:00.088 CNTRLR [Node 002] [+] [Meter] value[66561]: 232.3 [Endpoint 0] 20:34:00.089 CNTRLR [Node 002] [+] [Meter] deltaTime[66561]: 0 [Endpoint 0] 20:34:00.089 SERIAL » [ACK] (0x06) 20:34:00.090 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: V rate type: Consumed value: 232.3 time delta: 0 seconds 20:34:00.093 SERIAL » 0x01090013130225022504f2 (11 bytes) 20:34:00.094 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 4 └─[BinarySwitchCCGet] 20:34:00.094 CNTRLR » [Node 002] querying meter value (type = Electric, scale = A)... 20:34:00.097 SERIAL « [ACK] (0x06) 20:34:00.099 SERIAL « 0x0104011301e8 (6 bytes) 20:34:00.100 SERIAL » [ACK] (0x06) 20:34:00.102 DRIVER « [RES] [SendData] was sent: true 20:34:00.239 SERIAL « 0x010700130400000ee1 (9 bytes) 20:34:00.240 SERIAL » [ACK] (0x06) 20:34:00.241 DRIVER « [REQ] [SendData] callback id: 4 transmit status: OK 20:34:00.363 SERIAL « 0x01090004001303250300c4 (11 bytes) 20:34:00.364 CNTRLR [Node 019] [+] [Binary Switch] currentValue: false [Endpoint 0] 20:34:00.365 SERIAL » [ACK] (0x06) 20:34:00.366 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 20:34:00.368 SERIAL » 0x010a001312037005022505a0 (12 bytes) 20:34:00.369 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 5 └─[ConfigurationCCGet] parameter #: 2 20:34:00.369 CNTRLR « [Node 019] received Binary Switch state: current value: false 20:34:00.369 CNTRLR [Node 019] [+] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] 20:34:00.374 SERIAL « [ACK] (0x06) 20:34:00.376 SERIAL « 0x0104011301e8 (6 bytes) 20:34:00.377 SERIAL » [ACK] (0x06) 20:34:00.377 DRIVER « [RES] [SendData] was sent: true 20:34:00.379 CNTRLR [Node 019] ConfigurationCC: Loading configuration parameters from device confi g 20:34:00.379 CNTRLR [Node 019] [+] [Configuration] isParamInformationFromConfig: false [internal] 20:34:00.380 CNTRLR [Node 019] [Configuration] 1: metadata updated 20:34:00.381 CNTRLR [Node 019] [Configuration] 2: metadata updated 20:34:00.382 CNTRLR [Node 019] [Configuration] 3: metadata updated 20:34:00.383 CNTRLR [Node 019] [Configuration] 10: metadata updated 20:34:00.383 CNTRLR [Node 019] [Configuration] 11: metadata updated 20:34:00.384 CNTRLR [Node 019] [Configuration] 12: metadata updated 20:34:00.385 CNTRLR [Node 019] [Configuration] 13: metadata updated 20:34:00.386 CNTRLR [Node 019] [Configuration] 14: metadata updated 20:34:00.387 CNTRLR [Node 019] [Configuration] 15: metadata updated 20:34:00.388 CNTRLR [Node 019] [Configuration] 20: metadata updated 20:34:00.388 CNTRLR [Node 019] [Configuration] 21: metadata updated 20:34:00.389 CNTRLR [Node 019] [Configuration] 22: metadata updated 20:34:00.390 CNTRLR [Node 019] [Configuration] 23: metadata updated 20:34:00.391 CNTRLR [Node 019] [Configuration] 24: metadata updated 20:34:00.392 CNTRLR [Node 019] [Configuration] 30: metadata updated 20:34:00.393 CNTRLR [Node 019] [Configuration] 31: metadata updated 20:34:00.394 CNTRLR [Node 019] [Configuration] 32: metadata updated 20:34:00.394 CNTRLR [Node 019] [Configuration] 40: metadata updated 20:34:00.395 CNTRLR [Node 019] [Configuration] 41: metadata updated 20:34:00.396 CNTRLR [Node 019] [Configuration] 42: metadata updated 20:34:00.397 CNTRLR [Node 019] [Configuration] 43: metadata updated 20:34:00.398 CNTRLR [Node 019] [Configuration] 50: metadata updated 20:34:00.398 CNTRLR [Node 019] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 20:34:00.399 CNTRLR » [Node 019] querying parameter #1 value... 20:34:00.494 SERIAL « 0x010700130500000ce2 (9 bytes) 20:34:00.495 SERIAL » [ACK] (0x06) 20:34:00.496 DRIVER « [REQ] [SendData] callback id: 5 transmit status: OK 20:34:00.504 SERIAL « 0x010c000400120670060202000693 (14 bytes) 20:34:00.506 CNTRLR [Node 018] [+] [Configuration] 2: 6 20:34:00.506 SERIAL » [ACK] (0x06) 20:34:00.507 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 2 value: 6 20:34:00.510 SERIAL » 0x01090013140232032506e1 (11 bytes) 20:34:00.510 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 6 └─[MeterCCSupportedGet] 20:34:00.510 CNTRLR « [Node 018] parameter #2 has value: 6 20:34:00.511 CNTRLR » [Node 018] querying parameter #3 value... 20:34:00.515 SERIAL « [ACK] (0x06) 20:34:00.516 SERIAL « 0x0104011301e8 (6 bytes) 20:34:00.516 SERIAL » [ACK] (0x06) 20:34:00.517 DRIVER « [RES] [SendData] was sent: true 20:34:00.535 SERIAL « 0x0107001306000002ef (9 bytes) 20:34:00.535 SERIAL » [ACK] (0x06) 20:34:00.536 DRIVER « [REQ] [SendData] callback id: 6 transmit status: OK 20:34:00.559 SERIAL « 0x010a00040014043204817523 (12 bytes) 20:34:00.560 CNTRLR [Node 020] [+] [Meter] type: 1 [Endpoint 0] [internal] 20:34:00.560 CNTRLR [Node 020] [+] [Meter] supportsReset: true [Endpoint 0] [internal] 20:34:00.560 CNTRLR [Node 020] [+] [Meter] supportedScales: 0,2,4,5,6 [Endpoint 0] [internal] 20:34:00.561 CNTRLR [Node 020] [+] [Meter] supportedRateTypes: [Endpoint 0] [internal] 20:34:00.561 CNTRLR [Node 020] [Meter] reset: metadata updated [Endpoint 0] 20:34:00.562 SERIAL » [ACK] (0x06) 20:34:00.562 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MeterCCSupportedReport] type: Electric supports reset: true supported scales: · kWh · W · V · A · Power Factor supported rate types: 20:34:00.566 SERIAL » 0x010a0013150386137a25073d (12 bytes) 20:34:00.566 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 7 └─[VersionCCCommandClassGet] CC: Firmware Update Meta Data 20:34:00.567 CNTRLR « [Node 020] received meter support: type: Electric supported scales: · kWh · W · V · A · Power Factor supported rate types: supports reset: true 20:34:00.567 CNTRLR » [Node 020] querying meter value (type = Electric, scale = kWh)... 20:34:00.570 SERIAL « [ACK] (0x06) 20:34:00.572 SERIAL « 0x0104011301e8 (6 bytes) 20:34:00.572 SERIAL » [ACK] (0x06) 20:34:00.573 DRIVER « [RES] [SendData] was sent: true 20:34:01.974 SERIAL « 0x010700130700008d61 (9 bytes) 20:34:01.974 SERIAL » [ACK] (0x06) 20:34:01.975 DRIVER « [REQ] [SendData] callback id: 7 transmit status: OK 20:34:02.058 SERIAL « 0x010a000400150486147a030b (12 bytes) 20:34:02.059 SERIAL » [ACK] (0x06) 20:34:02.060 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Firmware Update Meta Data version: 3 20:34:02.062 SERIAL » 0x010a0013160386137a250831 (12 bytes) 20:34:02.062 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 8 └─[VersionCCCommandClassGet] CC: Firmware Update Meta Data 20:34:02.062 CNTRLR [Node 021] supports CC Firmware Update Meta Data (0x7a) in version 3 20:34:02.062 CNTRLR [Node 021] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 20:34:02.062 CNTRLR [Node 021] trying to load device config 20:34:02.063 SERIAL « [ACK] (0x06) 20:34:02.065 CNTRLR [Node 021] device config loaded 20:34:02.067 CNTRLR [Node 021] ZWavePlusCC: doing a complete interview... 20:34:02.067 CNTRLR » [Node 021] querying Z-Wave+ information... 20:34:02.068 SERIAL « 0x0104011301e8 (6 bytes) 20:34:02.068 SERIAL » [ACK] (0x06) 20:34:02.068 DRIVER « [RES] [SendData] was sent: true 20:34:03.513 SERIAL « 0x010700130800009172 (9 bytes) 20:34:03.513 SERIAL » [ACK] (0x06) 20:34:03.514 DRIVER « [REQ] [SendData] callback id: 8 transmit status: OK 20:34:03.593 SERIAL « 0x010a000400160486147a0308 (12 bytes) 20:34:03.593 SERIAL » [ACK] (0x06) 20:34:03.594 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Firmware Update Meta Data version: 3 20:34:03.597 SERIAL » 0x010a0013170386137a250931 (12 bytes) 20:34:03.597 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 9 └─[VersionCCCommandClassGet] CC: Firmware Update Meta Data 20:34:03.598 CNTRLR [Node 022] supports CC Firmware Update Meta Data (0x7a) in version 3 20:34:03.598 CNTRLR [Node 022] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 20:34:03.598 CNTRLR [Node 022] trying to load device config 20:34:03.599 SERIAL « [ACK] (0x06) 20:34:03.601 CNTRLR [Node 022] device config loaded 20:34:03.603 CNTRLR [Node 022] ZWavePlusCC: doing a complete interview... 20:34:03.603 CNTRLR » [Node 022] querying Z-Wave+ information... 20:34:03.604 SERIAL « 0x0104011301e8 (6 bytes) 20:34:03.604 SERIAL » [ACK] (0x06) 20:34:03.604 DRIVER « [RES] [SendData] was sent: true 20:34:05.088 SERIAL « 0x010c0004001c0631050422023ec3 (14 bytes) 20:34:05.088 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:34:05.089 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 72.5 => 57.4 [Endpoint 0] 20:34:05.089 SERIAL » [ACK] (0x06) 20:34:05.089 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 57.4 20:34:05.110 SERIAL « 0x010700130900009775 (9 bytes) 20:34:05.110 SERIAL » [ACK] (0x06) 20:34:05.111 DRIVER « [REQ] [SendData] callback id: 9 transmit status: OK 20:34:05.163 SERIAL « 0x010c0004001c0631050422023ec3 (14 bytes) 20:34:05.164 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:34:05.165 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 57.4 => 57.4 [Endpoint 0] 20:34:05.165 SERIAL » [ACK] (0x06) 20:34:05.166 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 57.4 20:34:05.192 SERIAL « 0x010a000400170486147a0309 (12 bytes) 20:34:05.192 SERIAL » [ACK] (0x06) 20:34:05.193 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Firmware Update Meta Data version: 3 20:34:05.196 SERIAL » 0x010a0013180386137a250a3d (12 bytes) 20:34:05.196 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 10 └─[VersionCCCommandClassGet] CC: Firmware Update Meta Data 20:34:05.197 CNTRLR [Node 023] supports CC Firmware Update Meta Data (0x7a) in version 3 20:34:05.197 CNTRLR [Node 023] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 20:34:05.197 CNTRLR [Node 023] trying to load device config 20:34:05.199 SERIAL « [ACK] (0x06) 20:34:05.204 CNTRLR [Node 023] device config loaded 20:34:05.205 SERIAL « 0x0104011301e8 (6 bytes) 20:34:05.205 SERIAL » [ACK] (0x06) 20:34:05.209 DRIVER « [RES] [SendData] was sent: true 20:34:05.211 CNTRLR [Node 023] ZWavePlusCC: doing a complete interview... 20:34:05.212 CNTRLR » [Node 023] querying Z-Wave+ information... 20:34:06.591 SERIAL « 0x010700130a00008c6d (9 bytes) 20:34:06.591 SERIAL » [ACK] (0x06) 20:34:06.592 DRIVER « [REQ] [SendData] callback id: 10 transmit status: OK 20:34:06.673 SERIAL « 0x010a000400180486147a0306 (12 bytes) 20:34:06.673 SERIAL » [ACK] (0x06) 20:34:06.674 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Firmware Update Meta Data version: 3 20:34:06.677 SERIAL » 0x010900131a022502250bf4 (11 bytes) 20:34:06.677 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 11 └─[BinarySwitchCCGet] 20:34:06.677 CNTRLR [Node 024] supports CC Firmware Update Meta Data (0x7a) in version 3 20:34:06.678 CNTRLR [Node 024] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 20:34:06.678 CNTRLR [Node 024] trying to load device config 20:34:06.680 SERIAL « [ACK] (0x06) 20:34:06.685 CNTRLR [Node 024] device config loaded 20:34:06.686 SERIAL « 0x0104011301e8 (6 bytes) 20:34:06.686 SERIAL » [ACK] (0x06) 20:34:06.696 DRIVER « [RES] [SendData] was sent: true 20:34:06.698 CNTRLR [Node 024] ZWavePlusCC: doing a complete interview... 20:34:06.699 CNTRLR » [Node 024] querying Z-Wave+ information... 20:34:06.790 SERIAL « 0x010700130b00000beb (9 bytes) 20:34:06.790 SERIAL » [ACK] (0x06) 20:34:06.791 DRIVER « [REQ] [SendData] callback id: 11 transmit status: OK 20:34:06.861 SERIAL « 0x01090004001a032503ff32 (11 bytes) 20:34:06.862 CNTRLR [Node 026] [+] [Binary Switch] currentValue: true [Endpoint 0] 20:34:06.862 SERIAL » [ACK] (0x06) 20:34:06.863 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: true 20:34:06.866 SERIAL » 0x010900131c022502250cf5 (11 bytes) 20:34:06.866 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 12 └─[BinarySwitchCCGet] 20:34:06.867 CNTRLR « [Node 026] received Binary Switch state: current value: true 20:34:06.867 CNTRLR [Node 026] [+] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] 20:34:06.874 SERIAL « [ACK] (0x06) 20:34:06.879 SERIAL « 0x0104011301e8 (6 bytes) 20:34:06.880 SERIAL » [ACK] (0x06) 20:34:06.881 DRIVER « [RES] [SendData] was sent: true 20:34:06.883 CNTRLR [Node 026] ConfigurationCC: Loading configuration parameters from device confi g 20:34:06.885 CNTRLR [Node 026] [+] [Configuration] isParamInformationFromConfig: false [internal] 20:34:06.886 CNTRLR [Node 026] [Configuration] 1: metadata updated 20:34:06.888 CNTRLR [Node 026] [Configuration] 2: metadata updated 20:34:06.889 CNTRLR [Node 026] [Configuration] 3: metadata updated 20:34:06.891 CNTRLR [Node 026] [Configuration] 10: metadata updated 20:34:06.892 CNTRLR [Node 026] [Configuration] 11: metadata updated 20:34:06.893 CNTRLR [Node 026] [Configuration] 12: metadata updated 20:34:06.893 CNTRLR [Node 026] [Configuration] 13: metadata updated 20:34:06.894 CNTRLR [Node 026] [Configuration] 14: metadata updated 20:34:06.895 CNTRLR [Node 026] [Configuration] 15: metadata updated 20:34:06.895 CNTRLR [Node 026] [Configuration] 20: metadata updated 20:34:06.896 CNTRLR [Node 026] [Configuration] 21: metadata updated 20:34:06.897 CNTRLR [Node 026] [Configuration] 22: metadata updated 20:34:06.897 CNTRLR [Node 026] [Configuration] 23: metadata updated 20:34:06.898 CNTRLR [Node 026] [Configuration] 24: metadata updated 20:34:06.899 CNTRLR [Node 026] [Configuration] 30: metadata updated 20:34:06.899 CNTRLR [Node 026] [Configuration] 31: metadata updated 20:34:06.900 CNTRLR [Node 026] [Configuration] 32: metadata updated 20:34:06.900 CNTRLR [Node 026] [Configuration] 40: metadata updated 20:34:06.900 CNTRLR [Node 026] [Configuration] 41: metadata updated 20:34:06.901 CNTRLR [Node 026] [Configuration] 42: metadata updated 20:34:06.901 CNTRLR [Node 026] [Configuration] 43: metadata updated 20:34:06.902 CNTRLR [Node 026] [Configuration] 50: metadata updated 20:34:06.902 CNTRLR [Node 026] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 20:34:06.902 CNTRLR » [Node 026] querying parameter #1 value... 20:34:06.944 SERIAL « 0x010700130c000008ef (9 bytes) 20:34:06.944 SERIAL » [ACK] (0x06) 20:34:06.945 DRIVER « [REQ] [SendData] callback id: 12 transmit status: OK 20:34:06.954 SERIAL « 0x01090004001c032503ff34 (11 bytes) 20:34:06.954 CNTRLR [Node 028] [+] [Binary Switch] currentValue: true [Endpoint 0] 20:34:06.955 SERIAL » [ACK] (0x06) 20:34:06.955 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: true 20:34:06.956 SERIAL » 0x010a00130303700503250db8 (12 bytes) 20:34:06.956 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 13 └─[ConfigurationCCGet] parameter #: 3 20:34:06.956 CNTRLR « [Node 028] received Binary Switch state: current value: true 20:34:06.956 CNTRLR [Node 028] [+] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] 20:34:06.957 CNTRLR [Node 028] ConfigurationCC: Loading configuration parameters from device confi g 20:34:06.957 CNTRLR [Node 028] [+] [Configuration] isParamInformationFromConfig: false [internal] 20:34:06.957 CNTRLR [Node 028] [Configuration] 1: metadata updated 20:34:06.957 CNTRLR [Node 028] [Configuration] 2: metadata updated 20:34:06.958 CNTRLR [Node 028] [Configuration] 3: metadata updated 20:34:06.958 CNTRLR [Node 028] [Configuration] 10: metadata updated 20:34:06.958 CNTRLR [Node 028] [Configuration] 11: metadata updated 20:34:06.959 CNTRLR [Node 028] [Configuration] 12: metadata updated 20:34:06.959 CNTRLR [Node 028] [Configuration] 13: metadata updated 20:34:06.959 CNTRLR [Node 028] [Configuration] 14: metadata updated 20:34:06.960 CNTRLR [Node 028] [Configuration] 15: metadata updated 20:34:06.960 CNTRLR [Node 028] [Configuration] 20: metadata updated 20:34:06.961 CNTRLR [Node 028] [Configuration] 21: metadata updated 20:34:06.961 CNTRLR [Node 028] [Configuration] 22: metadata updated 20:34:06.961 CNTRLR [Node 028] [Configuration] 23: metadata updated 20:34:06.962 CNTRLR [Node 028] [Configuration] 24: metadata updated 20:34:06.962 CNTRLR [Node 028] [Configuration] 30: metadata updated 20:34:06.962 CNTRLR [Node 028] [Configuration] 31: metadata updated 20:34:06.962 CNTRLR [Node 028] [Configuration] 32: metadata updated 20:34:06.963 CNTRLR [Node 028] [Configuration] 40: metadata updated 20:34:06.963 CNTRLR [Node 028] [Configuration] 41: metadata updated 20:34:06.963 CNTRLR [Node 028] [Configuration] 42: metadata updated 20:34:06.964 CNTRLR [Node 028] [Configuration] 43: metadata updated 20:34:06.964 CNTRLR [Node 028] [Configuration] 50: metadata updated 20:34:06.964 CNTRLR [Node 028] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 20:34:06.964 CNTRLR » [Node 028] querying parameter #1 value... 20:34:06.970 SERIAL « [ACK] (0x06) 20:34:06.971 SERIAL « 0x0104011301e8 (6 bytes) 20:34:06.971 SERIAL » [ACK] (0x06) 20:34:06.976 DRIVER « [RES] [SendData] was sent: true 20:34:06.982 SERIAL « 0x010700130d000003e5 (9 bytes) 20:34:06.982 SERIAL » [ACK] (0x06) 20:34:06.982 DRIVER « [REQ] [SendData] callback id: 13 transmit status: OK 20:34:06.995 SERIAL « 0x010c000400030670060302000085 (14 bytes) 20:34:06.996 CNTRLR [Node 003] [+] [Configuration] 3: 0 20:34:06.997 SERIAL » [ACK] (0x06) 20:34:06.998 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 2 value: 0 20:34:07.001 SERIAL » 0x010a00130503700505250ebb (12 bytes) 20:34:07.001 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 14 └─[ConfigurationCCGet] parameter #: 5 20:34:07.001 CNTRLR « [Node 003] parameter #3 has value: 0 20:34:07.001 CNTRLR » [Node 003] querying parameter #10 value... 20:34:07.004 SERIAL « [ACK] (0x06) 20:34:07.006 SERIAL « 0x0104011301e8 (6 bytes) 20:34:07.006 SERIAL » [ACK] (0x06) 20:34:07.007 DRIVER « [RES] [SendData] was sent: true 20:34:07.021 SERIAL « 0x010700130e000002e7 (9 bytes) 20:34:07.021 SERIAL » [ACK] (0x06) 20:34:07.022 DRIVER « [REQ] [SendData] callback id: 14 transmit status: OK 20:34:07.031 SERIAL « 0x010b0004000505700605010183 (13 bytes) 20:34:07.033 CNTRLR [Node 005] [+] [Configuration] 5: 1 20:34:07.033 SERIAL » [ACK] (0x06) 20:34:07.034 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 1 value: 1 20:34:07.037 SERIAL » 0x010a00130603700505250fb9 (12 bytes) 20:34:07.037 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 15 └─[ConfigurationCCGet] parameter #: 5 20:34:07.037 CNTRLR « [Node 005] parameter #5 has value: 1 20:34:07.038 CNTRLR » [Node 005] querying parameter #6 value... 20:34:07.041 SERIAL « [ACK] (0x06) 20:34:07.043 SERIAL « 0x0104011301e8 (6 bytes) 20:34:07.043 SERIAL » [ACK] (0x06) 20:34:07.044 DRIVER « [RES] [SendData] was sent: true 20:34:07.057 SERIAL « 0x010700130f000002e6 (9 bytes) 20:34:07.058 SERIAL » [ACK] (0x06) 20:34:07.058 DRIVER « [REQ] [SendData] callback id: 15 transmit status: OK 20:34:07.067 SERIAL « 0x010b0004000605700605010180 (13 bytes) 20:34:07.068 CNTRLR [Node 006] [+] [Configuration] 5: 1 20:34:07.069 SERIAL » [ACK] (0x06) 20:34:07.069 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 1 value: 1 20:34:07.070 SERIAL » 0x010a001302033201282510c9 (12 bytes) 20:34:07.071 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[MeterCCGet] duration: A 20:34:07.071 CNTRLR « [Node 006] parameter #5 has value: 1 20:34:07.071 CNTRLR » [Node 006] querying parameter #6 value... 20:34:07.072 SERIAL « [ACK] (0x06) 20:34:07.076 SERIAL « 0x0104011301e8 (6 bytes) 20:34:07.076 SERIAL » [ACK] (0x06) 20:34:07.077 DRIVER « [RES] [SendData] was sent: true 20:34:07.095 SERIAL « 0x0107001310000002f9 (9 bytes) 20:34:07.096 SERIAL » [ACK] (0x06) 20:34:07.096 DRIVER « [REQ] [SendData] callback id: 16 transmit status: OK 20:34:07.126 SERIAL « 0x0110000400020a3202a14a00000000000038 (18 bytes) 20:34:07.127 CNTRLR [Node 002] [Meter] value[66817]: metadata updated [Endpoint 0] 20:34:07.128 CNTRLR [Node 002] [Meter] previousValue[66817]: metadata updated [Endpoint 0] 20:34:07.128 CNTRLR [Node 002] [Meter] deltaTime[66817]: metadata updated [Endpoint 0] 20:34:07.129 CNTRLR [Node 002] [+] [Meter] value[66817]: 0 [Endpoint 0] 20:34:07.130 CNTRLR [Node 002] [+] [Meter] deltaTime[66817]: 0 [Endpoint 0] 20:34:07.130 SERIAL » [ACK] (0x06) 20:34:07.131 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: A rate type: Consumed value: 0 time delta: 0 seconds 20:34:07.141 SERIAL » 0x010a001313037005012511b6 (12 bytes) 20:34:07.142 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 17 └─[ConfigurationCCGet] parameter #: 1 20:34:07.142 CNTRLR » [Node 002] querying meter value (type = Electric, scale = Power Factor)... 20:34:07.144 SERIAL « [ACK] (0x06) 20:34:07.147 SERIAL « 0x0104011301e8 (6 bytes) 20:34:07.147 SERIAL » [ACK] (0x06) 20:34:07.147 DRIVER « [RES] [SendData] was sent: true 20:34:07.289 SERIAL « 0x010700131100000ef4 (9 bytes) 20:34:07.290 SERIAL » [ACK] (0x06) 20:34:07.290 DRIVER « [REQ] [SendData] callback id: 17 transmit status: OK 20:34:07.419 SERIAL « 0x010b0004001305700601010090 (13 bytes) 20:34:07.420 CNTRLR [Node 019] [+] [Configuration] 1: 0 20:34:07.421 SERIAL » [ACK] (0x06) 20:34:07.422 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 0 20:34:07.425 SERIAL » 0x010a001312037005032512b6 (12 bytes) 20:34:07.425 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 18 └─[ConfigurationCCGet] parameter #: 3 20:34:07.426 CNTRLR « [Node 019] parameter #1 has value: 0 20:34:07.426 CNTRLR » [Node 019] querying parameter #2 value... 20:34:07.429 SERIAL « [ACK] (0x06) 20:34:07.431 SERIAL « 0x0104011301e8 (6 bytes) 20:34:07.431 SERIAL » [ACK] (0x06) 20:34:07.432 DRIVER « [RES] [SendData] was sent: true 20:34:07.544 SERIAL « 0x010700131200000cf5 (9 bytes) 20:34:07.545 SERIAL » [ACK] (0x06) 20:34:07.545 DRIVER « [REQ] [SendData] callback id: 18 transmit status: OK 20:34:07.555 SERIAL « 0x010c000400120670060302051485 (14 bytes) 20:34:07.556 CNTRLR [Node 018] [+] [Configuration] 3: 1300 20:34:07.557 SERIAL » [ACK] (0x06) 20:34:07.558 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 2 value: 1300 20:34:07.563 SERIAL » 0x010a001314033201002513f4 (12 bytes) 20:34:07.563 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 19 └─[MeterCCGet] duration: kWh 20:34:07.564 CNTRLR « [Node 018] parameter #3 has value: 1300 20:34:07.564 CNTRLR » [Node 018] querying parameter #4 value... 20:34:07.568 SERIAL « [ACK] (0x06) 20:34:07.570 SERIAL « 0x0104011301e8 (6 bytes) 20:34:07.571 SERIAL » [ACK] (0x06) 20:34:07.573 DRIVER « [RES] [SendData] was sent: true 20:34:07.588 SERIAL « 0x0107001313000002fa (9 bytes) 20:34:07.589 SERIAL » [ACK] (0x06) 20:34:07.589 DRIVER « [REQ] [SendData] callback id: 19 transmit status: OK 20:34:07.620 SERIAL « 0x0114000400140e320221440000017901fa000001795b (22 bytes) 20:34:07.621 CNTRLR [Node 020] [Meter] value[65537]: metadata updated [Endpoint 0] 20:34:07.622 CNTRLR [Node 020] [Meter] previousValue[65537]: metadata updated [Endpoint 0] 20:34:07.623 CNTRLR [Node 020] [Meter] deltaTime[65537]: metadata updated [Endpoint 0] 20:34:07.623 CNTRLR [Node 020] [+] [Meter] value[65537]: 3.77 [Endpoint 0] 20:34:07.624 CNTRLR [Node 020] [+] [Meter] previousValue[65537]: 3.77 [Endpoint 0] 20:34:07.624 CNTRLR [Node 020] [+] [Meter] deltaTime[65537]: 506 [Endpoint 0] 20:34:07.625 SERIAL » [ACK] (0x06) 20:34:07.626 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 3.77 time delta: 506 seconds prev. value: 3.77 20:34:07.629 SERIAL » 0x0109001315025e0125149c (11 bytes) 20:34:07.629 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 20 └─[ZWavePlusCCGet] 20:34:07.629 CNTRLR » [Node 020] querying meter value (type = Electric, scale = W)... 20:34:07.639 SERIAL « [ACK] (0x06) 20:34:07.640 SERIAL « 0x0104011301e8 (6 bytes) 20:34:07.640 SERIAL » [ACK] (0x06) 20:34:07.641 DRIVER « [RES] [SendData] was sent: true 20:34:09.000 SERIAL « 0x010700131400008877 (9 bytes) 20:34:09.000 SERIAL » [ACK] (0x06) 20:34:09.001 DRIVER « [REQ] [SendData] callback id: 20 transmit status: OK 20:34:09.086 SERIAL « 0x010f00040015095e0201070012001200b2 (17 bytes) 20:34:09.087 CNTRLR [Node 021] [+] [Z-Wave Plus Info] zwavePlusVersion: 1 [Endpoint 0] 20:34:09.088 CNTRLR [Node 021] [+] [Z-Wave Plus Info] nodeType: 0 [Endpoint 0] 20:34:09.088 CNTRLR [Node 021] [+] [Z-Wave Plus Info] roleType: 7 [Endpoint 0] 20:34:09.089 CNTRLR [Node 021] [+] [Z-Wave Plus Info] installerIcon: 4608 [Endpoint 0] 20:34:09.089 CNTRLR [Node 021] [+] [Z-Wave Plus Info] userIcon: 4608 [Endpoint 0] 20:34:09.089 SERIAL » [ACK] (0x06) 20:34:09.091 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ZWavePlusCCReport] version: 1 node type: Node role type: SleepingListeningSlave icon (mgmt.): 0x1200 icon (user): 0x1200 20:34:09.092 SERIAL » 0x0109001316025e0125159e (11 bytes) 20:34:09.092 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 21 └─[ZWavePlusCCGet] 20:34:09.093 CNTRLR « [Node 021] received response for Z-Wave+ information: Z-Wave+ version: 1 role type: SleepingListeningSlave node type: Node installer icon: 0x1200 user icon: 0x1200 20:34:09.093 CNTRLR [Node 021] [+] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue 20:34:09.096 SERIAL « [ACK] (0x06) 20:34:09.097 CNTRLR [Node 021] BatteryCC: doing a complete interview... 20:34:09.097 CNTRLR » [Node 021] querying battery status... 20:34:09.100 SERIAL « 0x0104011301e8 (6 bytes) 20:34:09.101 SERIAL » [ACK] (0x06) 20:34:09.101 DRIVER « [RES] [SendData] was sent: true 20:34:10.542 SERIAL « 0x01070013150000916f (9 bytes) 20:34:10.542 SERIAL » [ACK] (0x06) 20:34:10.543 DRIVER « [REQ] [SendData] callback id: 21 transmit status: OK 20:34:10.622 SERIAL « 0x010f00040016095e0201070012001200b1 (17 bytes) 20:34:10.623 CNTRLR [Node 022] [+] [Z-Wave Plus Info] zwavePlusVersion: 1 [Endpoint 0] 20:34:10.623 CNTRLR [Node 022] [+] [Z-Wave Plus Info] nodeType: 0 [Endpoint 0] 20:34:10.624 CNTRLR [Node 022] [+] [Z-Wave Plus Info] roleType: 7 [Endpoint 0] 20:34:10.624 CNTRLR [Node 022] [+] [Z-Wave Plus Info] installerIcon: 4608 [Endpoint 0] 20:34:10.625 CNTRLR [Node 022] [+] [Z-Wave Plus Info] userIcon: 4608 [Endpoint 0] 20:34:10.625 SERIAL » [ACK] (0x06) 20:34:10.626 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ZWavePlusCCReport] version: 1 node type: Node role type: SleepingListeningSlave icon (mgmt.): 0x1200 icon (user): 0x1200 20:34:10.628 SERIAL » 0x0109001317025e0125169c (11 bytes) 20:34:10.628 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 22 └─[ZWavePlusCCGet] 20:34:10.628 CNTRLR « [Node 022] received response for Z-Wave+ information: Z-Wave+ version: 1 role type: SleepingListeningSlave node type: Node installer icon: 0x1200 user icon: 0x1200 20:34:10.628 CNTRLR [Node 022] [+] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue 20:34:10.631 SERIAL « [ACK] (0x06) 20:34:10.632 CNTRLR [Node 022] BatteryCC: doing a complete interview... 20:34:10.632 CNTRLR » [Node 022] querying battery status... 20:34:10.633 SERIAL « 0x0104011301e8 (6 bytes) 20:34:10.633 SERIAL » [ACK] (0x06) 20:34:10.636 DRIVER « [RES] [SendData] was sent: true 20:34:13.287 SERIAL « 0x0107001316000109f5 (9 bytes) 20:34:13.287 SERIAL » [ACK] (0x06) 20:34:13.289 DRIVER « [REQ] [SendData] callback id: 22 transmit status: OK 20:34:13.370 SERIAL « 0x010f00040017095e0201070012001200b0 (17 bytes) 20:34:13.371 CNTRLR [Node 023] [+] [Z-Wave Plus Info] zwavePlusVersion: 1 [Endpoint 0] 20:34:13.372 CNTRLR [Node 023] [+] [Z-Wave Plus Info] nodeType: 0 [Endpoint 0] 20:34:13.372 CNTRLR [Node 023] [+] [Z-Wave Plus Info] roleType: 7 [Endpoint 0] 20:34:13.373 CNTRLR [Node 023] [+] [Z-Wave Plus Info] installerIcon: 4608 [Endpoint 0] 20:34:13.373 CNTRLR [Node 023] [+] [Z-Wave Plus Info] userIcon: 4608 [Endpoint 0] 20:34:13.373 SERIAL » [ACK] (0x06) 20:34:13.375 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ZWavePlusCCReport] version: 1 node type: Node role type: SleepingListeningSlave icon (mgmt.): 0x1200 icon (user): 0x1200 20:34:13.378 SERIAL » 0x0109001318025e01251792 (11 bytes) 20:34:13.379 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 23 └─[ZWavePlusCCGet] 20:34:13.379 CNTRLR « [Node 023] received response for Z-Wave+ information: Z-Wave+ version: 1 role type: SleepingListeningSlave node type: Node installer icon: 0x1200 user icon: 0x1200 20:34:13.379 CNTRLR [Node 023] [+] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue 20:34:13.385 SERIAL « [ACK] (0x06) 20:34:13.390 SERIAL « 0x0104011301e8 (6 bytes) 20:34:13.390 SERIAL » [ACK] (0x06) 20:34:13.392 DRIVER « [RES] [SendData] was sent: true 20:34:13.394 CNTRLR [Node 023] BatteryCC: doing a complete interview... 20:34:13.394 CNTRLR » [Node 023] querying battery status... 20:34:14.804 SERIAL « 0x010700131700008e72 (9 bytes) 20:34:14.805 SERIAL » [ACK] (0x06) 20:34:14.805 DRIVER « [REQ] [SendData] callback id: 23 transmit status: OK 20:34:14.885 SERIAL « 0x010f00040018095e0201070012001200bf (17 bytes) 20:34:14.885 CNTRLR [Node 024] [+] [Z-Wave Plus Info] zwavePlusVersion: 1 [Endpoint 0] 20:34:14.886 CNTRLR [Node 024] [+] [Z-Wave Plus Info] nodeType: 0 [Endpoint 0] 20:34:14.887 CNTRLR [Node 024] [+] [Z-Wave Plus Info] roleType: 7 [Endpoint 0] 20:34:14.887 CNTRLR [Node 024] [+] [Z-Wave Plus Info] installerIcon: 4608 [Endpoint 0] 20:34:14.887 CNTRLR [Node 024] [+] [Z-Wave Plus Info] userIcon: 4608 [Endpoint 0] 20:34:14.888 SERIAL » [ACK] (0x06) 20:34:14.889 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ZWavePlusCCReport] version: 1 node type: Node role type: SleepingListeningSlave icon (mgmt.): 0x1200 icon (user): 0x1200 20:34:14.892 SERIAL » 0x010a00131a037005012518b6 (12 bytes) 20:34:14.892 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 24 └─[ConfigurationCCGet] parameter #: 1 20:34:14.893 CNTRLR « [Node 024] received response for Z-Wave+ information: Z-Wave+ version: 1 role type: SleepingListeningSlave node type: Node installer icon: 0x1200 user icon: 0x1200 20:34:14.893 CNTRLR [Node 024] [+] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue 20:34:14.897 SERIAL « [ACK] (0x06) 20:34:14.899 SERIAL « 0x0104011301e8 (6 bytes) 20:34:14.899 SERIAL » [ACK] (0x06) 20:34:14.900 DRIVER « [RES] [SendData] was sent: true 20:34:14.901 CNTRLR [Node 024] BatteryCC: doing a complete interview... 20:34:14.901 CNTRLR » [Node 024] querying battery status... 20:34:15.000 SERIAL « 0x010700131800000bf8 (9 bytes) 20:34:15.001 SERIAL » [ACK] (0x06) 20:34:15.001 DRIVER « [REQ] [SendData] callback id: 24 transmit status: OK 20:34:15.071 SERIAL « 0x010b0004001a05700601010099 (13 bytes) 20:34:15.073 CNTRLR [Node 026] [+] [Configuration] 1: 0 20:34:15.074 SERIAL » [ACK] (0x06) 20:34:15.075 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 0 20:34:15.077 SERIAL » 0x010a00131c037005012519b1 (12 bytes) 20:34:15.078 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 25 └─[ConfigurationCCGet] parameter #: 1 20:34:15.078 CNTRLR « [Node 026] parameter #1 has value: 0 20:34:15.078 CNTRLR » [Node 026] querying parameter #2 value... 20:34:15.086 SERIAL « [ACK] (0x06) 20:34:15.087 SERIAL « 0x0104011301e8 (6 bytes) 20:34:15.087 SERIAL » [ACK] (0x06) 20:34:15.088 DRIVER « [RES] [SendData] was sent: true 20:34:15.154 SERIAL « 0x0107001319000007f5 (9 bytes) 20:34:15.155 SERIAL » [ACK] (0x06) 20:34:15.155 DRIVER « [REQ] [SendData] callback id: 25 transmit status: OK 20:34:15.164 SERIAL « 0x010b0004001c0570060101009f (13 bytes) 20:34:15.165 CNTRLR [Node 028] [+] [Configuration] 1: 0 20:34:15.166 SERIAL » [ACK] (0x06) 20:34:15.167 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 0 20:34:15.170 SERIAL » 0x010a0013030370050a251aa6 (12 bytes) 20:34:15.170 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 26 └─[ConfigurationCCGet] parameter #: 10 20:34:15.171 CNTRLR « [Node 028] parameter #1 has value: 0 20:34:15.171 CNTRLR » [Node 028] querying parameter #2 value... 20:34:15.174 SERIAL « [ACK] (0x06) 20:34:15.176 SERIAL « 0x0104011301e8 (6 bytes) 20:34:15.176 SERIAL » [ACK] (0x06) 20:34:15.177 DRIVER « [RES] [SendData] was sent: true 20:34:15.195 SERIAL « 0x010700131a000002f3 (9 bytes) 20:34:15.196 SERIAL » [ACK] (0x06) 20:34:15.196 DRIVER « [REQ] [SendData] callback id: 26 transmit status: OK 20:34:15.208 SERIAL « 0x010b000400030570060a0150db (13 bytes) 20:34:15.209 CNTRLR [Node 003] [+] [Configuration] 10: 80 20:34:15.210 SERIAL » [ACK] (0x06) 20:34:15.211 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 80 20:34:15.214 SERIAL » 0x010a00130503700506251bad (12 bytes) 20:34:15.214 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 27 └─[ConfigurationCCGet] parameter #: 6 20:34:15.214 CNTRLR « [Node 003] parameter #10 has value: 80 20:34:15.215 CNTRLR » [Node 003] querying parameter #11 value... 20:34:15.218 SERIAL « [ACK] (0x06) 20:34:15.220 SERIAL « 0x0104011301e8 (6 bytes) 20:34:15.221 SERIAL » [ACK] (0x06) 20:34:15.221 DRIVER « [RES] [SendData] was sent: true 20:34:15.234 SERIAL « 0x010700131b000002f2 (9 bytes) 20:34:15.235 SERIAL » [ACK] (0x06) 20:34:15.235 DRIVER « [REQ] [SendData] callback id: 27 transmit status: OK 20:34:15.245 SERIAL « 0x010b0004000505700606010180 (13 bytes) 20:34:15.246 CNTRLR [Node 005] [+] [Configuration] 6: 1 20:34:15.247 SERIAL » [ACK] (0x06) 20:34:15.248 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 1 value: 1 20:34:15.251 SERIAL » 0x010a00130603700506251ca9 (12 bytes) 20:34:15.251 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 28 └─[ConfigurationCCGet] parameter #: 6 20:34:15.251 CNTRLR « [Node 005] parameter #6 has value: 1 20:34:15.251 CNTRLR » [Node 005] querying parameter #7 value... 20:34:15.255 SERIAL « [ACK] (0x06) 20:34:15.257 SERIAL « 0x0104011301e8 (6 bytes) 20:34:15.258 SERIAL » [ACK] (0x06) 20:34:15.258 DRIVER « [RES] [SendData] was sent: true 20:34:15.271 SERIAL « 0x010700131c000002f5 (9 bytes) 20:34:15.272 SERIAL » [ACK] (0x06) 20:34:15.272 DRIVER « [REQ] [SendData] callback id: 28 transmit status: OK 20:34:15.281 SERIAL « 0x010b0004000605700606010183 (13 bytes) 20:34:15.283 CNTRLR [Node 006] [+] [Configuration] 6: 1 20:34:15.283 SERIAL » [ACK] (0x06) 20:34:15.284 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 1 value: 1 20:34:15.287 SERIAL » 0x010a00130203320130251ddc (12 bytes) 20:34:15.288 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 29 └─[MeterCCGet] duration: Power Factor 20:34:15.288 CNTRLR « [Node 006] parameter #6 has value: 1 20:34:15.288 CNTRLR » [Node 006] querying parameter #7 value... 20:34:15.291 SERIAL « [ACK] (0x06) 20:34:15.293 SERIAL « 0x0104011301e8 (6 bytes) 20:34:15.293 SERIAL » [ACK] (0x06) 20:34:15.294 DRIVER « [RES] [SendData] was sent: true 20:34:15.313 SERIAL « 0x010700131d000003f5 (9 bytes) 20:34:15.313 SERIAL » [ACK] (0x06) 20:34:15.314 DRIVER « [REQ] [SendData] callback id: 29 transmit status: OK 20:34:15.342 SERIAL « 0x010e00040002083202a151000000003f (16 bytes) 20:34:15.343 CNTRLR [Node 002] [Meter] value[67073]: metadata updated [Endpoint 0] 20:34:15.344 CNTRLR [Node 002] [Meter] previousValue[67073]: metadata updated [Endpoint 0] 20:34:15.345 CNTRLR [Node 002] [Meter] deltaTime[67073]: metadata updated [Endpoint 0] 20:34:15.345 CNTRLR [Node 002] [+] [Meter] value[67073]: 0 [Endpoint 0] 20:34:15.346 CNTRLR [Node 002] [+] [Meter] deltaTime[67073]: 0 [Endpoint 0] 20:34:15.346 SERIAL » [ACK] (0x06) 20:34:15.347 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: Power Factor rate type: Consumed value: 0 time delta: 0 seconds 20:34:15.350 SERIAL » 0x010a00131303700502251eba (12 bytes) 20:34:15.351 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 30 └─[ConfigurationCCGet] parameter #: 2 20:34:15.351 CNTRLR [Node 002] [+] [Meter] interviewComplete: true [Endpoint 0] [internal] 20:34:15.357 SERIAL « [ACK] (0x06) 20:34:15.359 SERIAL « 0x0104011301e8 (6 bytes) 20:34:15.359 SERIAL » [ACK] (0x06) 20:34:15.360 DRIVER « [RES] [SendData] was sent: true 20:34:15.361 CNTRLR [Node 002] ConfigurationCC: Loading configuration parameters from device confi g 20:34:15.362 CNTRLR [Node 002] [+] [Configuration] isParamInformationFromConfig: false [internal] 20:34:15.363 CNTRLR [Node 002] [Configuration] 1: metadata updated 20:34:15.364 CNTRLR [Node 002] [Configuration] 2: metadata updated 20:34:15.365 CNTRLR [Node 002] [Configuration] 3: metadata updated 20:34:15.365 CNTRLR [Node 002] [Configuration] 4: metadata updated 20:34:15.366 CNTRLR [Node 002] [Configuration] 5: metadata updated 20:34:15.367 CNTRLR [Node 002] [Configuration] 6: metadata updated 20:34:15.368 CNTRLR [Node 002] [Configuration] 7: metadata updated 20:34:15.369 CNTRLR [Node 002] [Configuration] 8: metadata updated 20:34:15.369 CNTRLR [Node 002] [Configuration] 9: metadata updated 20:34:15.370 CNTRLR [Node 002] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 20:34:15.370 CNTRLR » [Node 002] querying parameter #1 value... 20:34:15.497 SERIAL « 0x010700131e00000efb (9 bytes) 20:34:15.498 SERIAL » [ACK] (0x06) 20:34:15.498 DRIVER « [REQ] [SendData] callback id: 30 transmit status: OK 20:34:15.627 SERIAL « 0x010b0004001305700602010192 (13 bytes) 20:34:15.629 CNTRLR [Node 019] [+] [Configuration] 2: 1 20:34:15.630 SERIAL » [ACK] (0x06) 20:34:15.630 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 1 20:34:15.633 SERIAL » 0x010a00131203700504251fbc (12 bytes) 20:34:15.633 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 31 └─[ConfigurationCCGet] parameter #: 4 20:34:15.634 CNTRLR « [Node 019] parameter #2 has value: 1 20:34:15.634 CNTRLR » [Node 019] querying parameter #3 value... 20:34:15.637 SERIAL « [ACK] (0x06) 20:34:15.639 SERIAL « 0x0104011301e8 (6 bytes) 20:34:15.639 SERIAL » [ACK] (0x06) 20:34:15.640 DRIVER « [RES] [SendData] was sent: true 20:34:15.754 SERIAL « 0x010700131f00000cf8 (9 bytes) 20:34:15.755 SERIAL » [ACK] (0x06) 20:34:15.755 DRIVER « [REQ] [SendData] callback id: 31 transmit status: OK 20:34:15.764 SERIAL « 0x010c0004001206700604022710a4 (14 bytes) 20:34:15.766 CNTRLR [Node 018] [+] [Configuration] 4: 10000 20:34:15.767 SERIAL » [ACK] (0x06) 20:34:15.767 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 2 value: 10000 20:34:15.770 SERIAL » 0x010a001314033201102520d7 (12 bytes) 20:34:15.771 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 32 └─[MeterCCGet] duration: W 20:34:15.771 CNTRLR « [Node 018] parameter #4 has value: 10000 20:34:15.771 CNTRLR » [Node 018] querying parameter #5 value... 20:34:15.774 SERIAL « [ACK] (0x06) 20:34:15.777 SERIAL « 0x0104011301e8 (6 bytes) 20:34:15.777 SERIAL » [ACK] (0x06) 20:34:15.778 DRIVER « [RES] [SendData] was sent: true 20:34:15.796 SERIAL « 0x0107001320000002c9 (9 bytes) 20:34:15.796 SERIAL » [ACK] (0x06) 20:34:15.797 DRIVER « [REQ] [SendData] callback id: 32 transmit status: OK 20:34:15.826 SERIAL « 0x0114000400140e3202213400000001000000000000d1 (22 bytes) 20:34:15.827 CNTRLR [Node 020] [Meter] value[66049]: metadata updated [Endpoint 0] 20:34:15.828 CNTRLR [Node 020] [Meter] previousValue[66049]: metadata updated [Endpoint 0] 20:34:15.829 CNTRLR [Node 020] [Meter] deltaTime[66049]: metadata updated [Endpoint 0] 20:34:15.829 CNTRLR [Node 020] [+] [Meter] value[66049]: 0.1 [Endpoint 0] 20:34:15.830 CNTRLR [Node 020] [+] [Meter] deltaTime[66049]: 0 [Endpoint 0] 20:34:15.830 SERIAL » [ACK] (0x06) 20:34:15.831 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0.1 time delta: 0 seconds 20:34:15.834 SERIAL » 0x0109001315028002252174 (11 bytes) 20:34:15.835 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 33 └─[BatteryCCGet] 20:34:15.835 CNTRLR » [Node 020] querying meter value (type = Electric, scale = V)... 20:34:15.838 SERIAL « [ACK] (0x06) 20:34:15.840 SERIAL « 0x0104011301e8 (6 bytes) 20:34:15.841 SERIAL » [ACK] (0x06) 20:34:15.841 DRIVER « [RES] [SendData] was sent: true 20:34:15.938 SERIAL « 0x0114000400140e3202213400000001000000000000d1 (22 bytes) 20:34:15.939 CNTRLR [Node 020] [~] [Meter] value[66049]: 0.1 => 0.1 [Endpoint 0] 20:34:15.940 CNTRLR [Node 020] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:34:15.941 SERIAL » [ACK] (0x06) 20:34:15.942 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0.1 time delta: 0 seconds 20:34:17.323 SERIAL « 0x01070013210000955f (9 bytes) 20:34:17.324 SERIAL » [ACK] (0x06) 20:34:17.324 DRIVER « [REQ] [SendData] callback id: 33 transmit status: OK 20:34:17.400 SERIAL « 0x0109000400150380034126 (11 bytes) 20:34:17.401 CNTRLR [Node 021] [+] [Battery] level: 65 [Endpoint 0] 20:34:17.402 CNTRLR [Node 021] [+] [Battery] isLow: false [Endpoint 0] 20:34:17.402 SERIAL » [ACK] (0x06) 20:34:17.404 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 65 is low: false 20:34:17.405 SERIAL » 0x0109001316028002252274 (11 bytes) 20:34:17.406 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 34 └─[BatteryCCGet] 20:34:17.406 CNTRLR « [Node 021] received response for battery information: level: 65 20:34:17.406 CNTRLR [Node 021] [+] [Battery] interviewComplete: true [Endpoint 0] [internal] 20:34:17.409 SERIAL « [ACK] (0x06) 20:34:17.410 CNTRLR [Node 021] ThermostatModeCC: doing a complete interview... 20:34:17.410 CNTRLR » [Node 021] querying supported thermostat modes... 20:34:17.413 SERIAL « 0x0104011301e8 (6 bytes) 20:34:17.413 SERIAL » [ACK] (0x06) 20:34:17.413 DRIVER « [RES] [SendData] was sent: true 20:34:18.800 SERIAL « 0x010700132200008b42 (9 bytes) 20:34:18.800 SERIAL » [ACK] (0x06) 20:34:18.801 DRIVER « [REQ] [SendData] callback id: 34 transmit status: OK 20:34:18.878 SERIAL « 0x0109000400160380036400 (11 bytes) 20:34:18.879 CNTRLR [Node 022] [+] [Battery] level: 100 [Endpoint 0] 20:34:18.880 CNTRLR [Node 022] [+] [Battery] isLow: false [Endpoint 0] 20:34:18.881 SERIAL » [ACK] (0x06) 20:34:18.882 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 20:34:18.887 SERIAL » 0x0109001317028002252374 (11 bytes) 20:34:18.887 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 35 └─[BatteryCCGet] 20:34:18.888 CNTRLR « [Node 022] received response for battery information: level: 100 20:34:18.888 CNTRLR [Node 022] [+] [Battery] interviewComplete: true [Endpoint 0] [internal] 20:34:18.897 SERIAL « [ACK] (0x06) 20:34:18.900 SERIAL « 0x0104011301e8 (6 bytes) 20:34:18.901 SERIAL » [ACK] (0x06) 20:34:18.902 DRIVER « [RES] [SendData] was sent: true 20:34:18.905 CNTRLR [Node 022] ThermostatModeCC: doing a complete interview... 20:34:18.905 CNTRLR » [Node 022] querying supported thermostat modes... 20:34:20.368 SERIAL « 0x01070013230000945c (9 bytes) 20:34:20.369 SERIAL » [ACK] (0x06) 20:34:20.369 DRIVER « [REQ] [SendData] callback id: 35 transmit status: OK 20:34:20.447 SERIAL « 0x0109000400170380033c59 (11 bytes) 20:34:20.449 CNTRLR [Node 023] [+] [Battery] level: 60 [Endpoint 0] 20:34:20.450 CNTRLR [Node 023] [+] [Battery] isLow: false [Endpoint 0] 20:34:20.450 SERIAL » [ACK] (0x06) 20:34:20.452 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 60 is low: false 20:34:20.454 SERIAL » 0x010900131802800225247c (11 bytes) 20:34:20.454 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 36 └─[BatteryCCGet] 20:34:20.454 CNTRLR « [Node 023] received response for battery information: level: 60 20:34:20.454 CNTRLR [Node 023] [+] [Battery] interviewComplete: true [Endpoint 0] [internal] 20:34:20.458 SERIAL « [ACK] (0x06) 20:34:20.459 SERIAL « 0x0104011301e8 (6 bytes) 20:34:20.460 SERIAL » [ACK] (0x06) 20:34:20.460 DRIVER « [RES] [SendData] was sent: true 20:34:20.461 CNTRLR [Node 023] ThermostatModeCC: doing a complete interview... 20:34:20.461 CNTRLR » [Node 023] querying supported thermostat modes... 20:34:21.936 SERIAL « 0x01070013240000945b (9 bytes) 20:34:21.936 SERIAL » [ACK] (0x06) 20:34:21.937 DRIVER « [REQ] [SendData] callback id: 36 transmit status: OK 20:34:22.045 SERIAL « 0x0109000400180380033c56 (11 bytes) 20:34:22.047 CNTRLR [Node 024] [+] [Battery] level: 60 [Endpoint 0] 20:34:22.048 CNTRLR [Node 024] [+] [Battery] isLow: false [Endpoint 0] 20:34:22.049 SERIAL » [ACK] (0x06) 20:34:22.050 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 60 is low: false 20:34:22.053 SERIAL » 0x010a00131a03700502252588 (12 bytes) 20:34:22.054 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 37 └─[ConfigurationCCGet] parameter #: 2 20:34:22.054 CNTRLR « [Node 024] received response for battery information: level: 60 20:34:22.054 CNTRLR [Node 024] [+] [Battery] interviewComplete: true [Endpoint 0] [internal] 20:34:22.060 SERIAL « [ACK] (0x06) 20:34:22.063 SERIAL « 0x0104011301e8 (6 bytes) 20:34:22.064 SERIAL » [ACK] (0x06) 20:34:22.065 DRIVER « [RES] [SendData] was sent: true 20:34:22.069 CNTRLR [Node 024] ThermostatModeCC: doing a complete interview... 20:34:22.069 CNTRLR » [Node 024] querying supported thermostat modes... 20:34:22.160 SERIAL « 0x010700132500000ac4 (9 bytes) 20:34:22.160 SERIAL » [ACK] (0x06) 20:34:22.161 DRIVER « [REQ] [SendData] callback id: 37 transmit status: OK 20:34:22.230 SERIAL « 0x010b0004001a0570060201019b (13 bytes) 20:34:22.232 CNTRLR [Node 026] [+] [Configuration] 2: 1 20:34:22.234 SERIAL » [ACK] (0x06) 20:34:22.235 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 1 20:34:22.239 SERIAL » 0x010a00131c0370050225268d (12 bytes) 20:34:22.239 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 38 └─[ConfigurationCCGet] parameter #: 2 20:34:22.240 CNTRLR « [Node 026] parameter #2 has value: 1 20:34:22.240 CNTRLR » [Node 026] querying parameter #3 value... 20:34:22.244 SERIAL « [ACK] (0x06) 20:34:22.246 SERIAL « 0x0104011301e8 (6 bytes) 20:34:22.246 SERIAL » [ACK] (0x06) 20:34:22.247 DRIVER « [RES] [SendData] was sent: true 20:34:22.314 SERIAL « 0x0107001326000007ca (9 bytes) 20:34:22.315 SERIAL » [ACK] (0x06) 20:34:22.315 DRIVER « [REQ] [SendData] callback id: 38 transmit status: OK 20:34:22.324 SERIAL « 0x010b0004001c0570060201019d (13 bytes) 20:34:22.326 CNTRLR [Node 028] [+] [Configuration] 2: 1 20:34:22.327 SERIAL » [ACK] (0x06) 20:34:22.328 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 1 20:34:22.333 SERIAL » 0x010a0013030370050b25279a (12 bytes) 20:34:22.333 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[ConfigurationCCGet] parameter #: 11 20:34:22.334 CNTRLR « [Node 028] parameter #2 has value: 1 20:34:22.334 CNTRLR » [Node 028] querying parameter #3 value... 20:34:22.338 SERIAL « [ACK] (0x06) 20:34:22.340 SERIAL « 0x0104011301e8 (6 bytes) 20:34:22.340 SERIAL » [ACK] (0x06) 20:34:22.341 DRIVER « [RES] [SendData] was sent: true 20:34:22.358 SERIAL « 0x0107001327000002ce (9 bytes) 20:34:22.359 SERIAL » [ACK] (0x06) 20:34:22.359 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 20:34:22.371 SERIAL « 0x010b000400030570060b010f85 (13 bytes) 20:34:22.373 CNTRLR [Node 003] [+] [Configuration] 11: 15 20:34:22.374 SERIAL » [ACK] (0x06) 20:34:22.374 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 11 value size: 1 value: 15 20:34:22.378 SERIAL » 0x010a0013050370050725289f (12 bytes) 20:34:22.379 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 40 └─[ConfigurationCCGet] parameter #: 7 20:34:22.379 CNTRLR « [Node 003] parameter #11 has value: 15 20:34:22.379 CNTRLR » [Node 003] querying parameter #12 value... 20:34:22.383 SERIAL « [ACK] (0x06) 20:34:22.386 SERIAL « 0x0104011301e8 (6 bytes) 20:34:22.387 SERIAL » [ACK] (0x06) 20:34:22.389 DRIVER « [RES] [SendData] was sent: true 20:34:22.399 SERIAL « 0x0107001328000001c2 (9 bytes) 20:34:22.400 SERIAL » [ACK] (0x06) 20:34:22.400 DRIVER « [REQ] [SendData] callback id: 40 transmit status: OK 20:34:22.409 SERIAL « 0x010b0004000505700607010181 (13 bytes) 20:34:22.410 CNTRLR [Node 005] [+] [Configuration] 7: 1 20:34:22.411 SERIAL » [ACK] (0x06) 20:34:22.413 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 7 value size: 1 value: 1 20:34:22.417 SERIAL » 0x010a0013060370050725299d (12 bytes) 20:34:22.417 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 41 └─[ConfigurationCCGet] parameter #: 7 20:34:22.418 CNTRLR « [Node 005] parameter #7 has value: 1 20:34:22.418 CNTRLR » [Node 005] querying parameter #8 value... 20:34:22.421 SERIAL « [ACK] (0x06) 20:34:22.424 SERIAL « 0x0104011301e8 (6 bytes) 20:34:22.424 SERIAL » [ACK] (0x06) 20:34:22.424 DRIVER « [RES] [SendData] was sent: true 20:34:22.438 SERIAL « 0x0107001329000002c0 (9 bytes) 20:34:22.438 SERIAL » [ACK] (0x06) 20:34:22.438 DRIVER « [REQ] [SendData] callback id: 41 transmit status: OK 20:34:22.447 SERIAL « 0x010b0004000605700607010182 (13 bytes) 20:34:22.448 CNTRLR [Node 006] [+] [Configuration] 7: 1 20:34:22.449 SERIAL » [ACK] (0x06) 20:34:22.449 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 7 value size: 1 value: 1 20:34:22.452 SERIAL » 0x010a00130203700501252a9c (12 bytes) 20:34:22.452 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 42 └─[ConfigurationCCGet] parameter #: 1 20:34:22.452 CNTRLR « [Node 006] parameter #7 has value: 1 20:34:22.452 CNTRLR » [Node 006] querying parameter #8 value... 20:34:22.454 SERIAL « [ACK] (0x06) 20:34:22.457 SERIAL « 0x0104011301e8 (6 bytes) 20:34:22.457 SERIAL » [ACK] (0x06) 20:34:22.457 DRIVER « [RES] [SendData] was sent: true 20:34:22.476 SERIAL « 0x010700132a000002c3 (9 bytes) 20:34:22.477 SERIAL » [ACK] (0x06) 20:34:22.477 DRIVER « [REQ] [SendData] callback id: 42 transmit status: OK 20:34:22.500 SERIAL « 0x010c00040002067006010202d054 (14 bytes) 20:34:22.501 CNTRLR [Node 002] [+] [Configuration] 1: 720 20:34:22.503 SERIAL » [ACK] (0x06) 20:34:22.503 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 2 value: 720 20:34:22.507 SERIAL » 0x010a00131303700503252b8e (12 bytes) 20:34:22.507 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 43 └─[ConfigurationCCGet] parameter #: 3 20:34:22.507 CNTRLR « [Node 002] parameter #1 has value: 720 20:34:22.507 CNTRLR » [Node 002] querying parameter #2 value... 20:34:22.511 SERIAL « [ACK] (0x06) 20:34:22.515 SERIAL « 0x0104011301e8 (6 bytes) 20:34:22.515 SERIAL » [ACK] (0x06) 20:34:22.517 DRIVER « [RES] [SendData] was sent: true 20:34:22.654 SERIAL « 0x010700132b00000fcf (9 bytes) 20:34:22.654 SERIAL » [ACK] (0x06) 20:34:22.655 DRIVER « [REQ] [SendData] callback id: 43 transmit status: OK 20:34:22.788 SERIAL « 0x010c000400130670060302000095 (14 bytes) 20:34:22.790 CNTRLR [Node 019] [+] [Configuration] 3: 0 20:34:22.791 SERIAL » [ACK] (0x06) 20:34:22.792 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 2 value: 0 20:34:22.795 SERIAL » 0x010a00131203700505252c8e (12 bytes) 20:34:22.795 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 44 └─[ConfigurationCCGet] parameter #: 5 20:34:22.795 CNTRLR « [Node 019] parameter #3 has value: 0 20:34:22.796 CNTRLR » [Node 019] querying parameter #10 value... 20:34:22.799 SERIAL « [ACK] (0x06) 20:34:22.802 SERIAL « 0x0104011301e8 (6 bytes) 20:34:22.803 SERIAL » [ACK] (0x06) 20:34:22.804 DRIVER « [RES] [SendData] was sent: true 20:34:22.914 SERIAL « 0x010700132c00000ccb (9 bytes) 20:34:22.915 SERIAL » [ACK] (0x06) 20:34:22.915 DRIVER « [REQ] [SendData] callback id: 44 transmit status: OK 20:34:22.924 SERIAL « 0x010b0004001205700605010194 (13 bytes) 20:34:22.928 CNTRLR [Node 018] [+] [Configuration] 5: 1 20:34:22.929 SERIAL » [ACK] (0x06) 20:34:22.929 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 1 value: 1 20:34:22.933 SERIAL » 0x010a00131403320120252dea (12 bytes) 20:34:22.933 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 45 └─[MeterCCGet] duration: V 20:34:22.934 CNTRLR « [Node 018] parameter #5 has value: 1 20:34:22.934 CNTRLR » [Node 018] querying parameter #6 value... 20:34:22.938 SERIAL « [ACK] (0x06) 20:34:22.941 SERIAL « 0x0104011301e8 (6 bytes) 20:34:22.941 SERIAL » [ACK] (0x06) 20:34:22.942 DRIVER « [RES] [SendData] was sent: true 20:34:22.983 SERIAL « 0x010700132d000005c3 (9 bytes) 20:34:22.983 SERIAL » [ACK] (0x06) 20:34:22.984 DRIVER « [REQ] [SendData] callback id: 45 transmit status: OK 20:34:23.019 SERIAL « 0x0110000400140a3202a12209170000000058 (18 bytes) 20:34:23.021 CNTRLR [Node 020] [Meter] value[66561]: metadata updated [Endpoint 0] 20:34:23.022 CNTRLR [Node 020] [Meter] previousValue[66561]: metadata updated [Endpoint 0] 20:34:23.022 CNTRLR [Node 020] [Meter] deltaTime[66561]: metadata updated [Endpoint 0] 20:34:23.023 CNTRLR [Node 020] [+] [Meter] value[66561]: 232.7 [Endpoint 0] 20:34:23.024 CNTRLR [Node 020] [+] [Meter] deltaTime[66561]: 0 [Endpoint 0] 20:34:23.024 SERIAL » [ACK] (0x06) 20:34:23.025 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: V rate type: Consumed value: 232.7 time delta: 0 seconds 20:34:23.029 SERIAL » 0x0109001315024004252ebd (11 bytes) 20:34:23.029 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 46 └─[ThermostatModeCCSupportedGet] 20:34:23.030 CNTRLR » [Node 020] querying meter value (type = Electric, scale = A)... 20:34:23.037 SERIAL « [ACK] (0x06) 20:34:23.038 SERIAL « 0x0104011301e8 (6 bytes) 20:34:23.038 SERIAL » [ACK] (0x06) 20:34:23.039 DRIVER « [RES] [SendData] was sent: true 20:34:24.471 SERIAL « 0x010700132e00009055 (9 bytes) 20:34:24.471 SERIAL » [ACK] (0x06) 20:34:24.472 DRIVER « [REQ] [SendData] callback id: 46 transmit status: OK 20:34:24.555 SERIAL « 0x010a0004001504400503882e (12 bytes) 20:34:24.556 CNTRLR [Node 021] [Thermostat Mode] mode: metadata updated [Endpoint 0] 20:34:24.557 CNTRLR [Node 021] [+] [Thermostat Mode] supportedModes: 0,1,1 [Endpoint 0] [internal] 1,15 20:34:24.558 SERIAL » [ACK] (0x06) 20:34:24.558 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ThermostatModeCCSupportedReport] supported modes: · Off · Heat · Energy heat · Full power 20:34:24.559 SERIAL » 0x0109001316024004252fbf (11 bytes) 20:34:24.560 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 47 └─[ThermostatModeCCSupportedGet] 20:34:24.560 CNTRLR « [Node 021] received supported thermostat modes: · Off · Heat · Energy heat · Full power 20:34:24.560 CNTRLR » [Node 021] querying current thermostat mode... 20:34:24.561 SERIAL « [ACK] (0x06) 20:34:24.565 SERIAL « 0x0104011301e8 (6 bytes) 20:34:24.565 SERIAL » [ACK] (0x06) 20:34:24.566 DRIVER « [RES] [SendData] was sent: true 20:34:25.994 SERIAL « 0x010700132f00008f4b (9 bytes) 20:34:25.995 SERIAL » [ACK] (0x06) 20:34:25.995 DRIVER « [REQ] [SendData] callback id: 47 transmit status: OK 20:34:26.072 SERIAL « 0x010a0004001604400503882d (12 bytes) 20:34:26.073 CNTRLR [Node 022] [Thermostat Mode] mode: metadata updated [Endpoint 0] 20:34:26.077 CNTRLR [Node 022] [+] [Thermostat Mode] supportedModes: 0,1,1 [Endpoint 0] [internal] 1,15 20:34:26.077 SERIAL » [ACK] (0x06) 20:34:26.079 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ThermostatModeCCSupportedReport] supported modes: · Off · Heat · Energy heat · Full power 20:34:26.084 SERIAL » 0x01090013170240042530a1 (11 bytes) 20:34:26.084 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 48 └─[ThermostatModeCCSupportedGet] 20:34:26.085 CNTRLR « [Node 022] received supported thermostat modes: · Off · Heat · Energy heat · Full power 20:34:26.085 CNTRLR » [Node 022] querying current thermostat mode... 20:34:26.090 SERIAL « [ACK] (0x06) 20:34:26.091 SERIAL « 0x0104011301e8 (6 bytes) 20:34:26.092 SERIAL » [ACK] (0x06) 20:34:26.092 DRIVER « [RES] [SendData] was sent: true 20:34:27.516 SERIAL « 0x010700133000008f54 (9 bytes) 20:34:27.516 SERIAL » [ACK] (0x06) 20:34:27.517 DRIVER « [REQ] [SendData] callback id: 48 transmit status: OK 20:34:27.592 SERIAL « 0x010a0004001704400503882c (12 bytes) 20:34:27.592 CNTRLR [Node 023] [Thermostat Mode] mode: metadata updated [Endpoint 0] 20:34:27.593 CNTRLR [Node 023] [+] [Thermostat Mode] supportedModes: 0,1,1 [Endpoint 0] [internal] 1,15 20:34:27.593 SERIAL » [ACK] (0x06) 20:34:27.594 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ThermostatModeCCSupportedReport] supported modes: · Off · Heat · Energy heat · Full power 20:34:27.596 SERIAL » 0x01090013180240042531af (11 bytes) 20:34:27.597 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 49 └─[ThermostatModeCCSupportedGet] 20:34:27.597 CNTRLR « [Node 023] received supported thermostat modes: · Off · Heat · Energy heat · Full power 20:34:27.597 CNTRLR » [Node 023] querying current thermostat mode... 20:34:27.601 SERIAL « [ACK] (0x06) 20:34:27.602 SERIAL « 0x0104011301e8 (6 bytes) 20:34:27.603 SERIAL » [ACK] (0x06) 20:34:27.603 DRIVER « [RES] [SendData] was sent: true 20:34:29.077 SERIAL « 0x01070013310000944e (9 bytes) 20:34:29.077 SERIAL » [ACK] (0x06) 20:34:29.078 DRIVER « [REQ] [SendData] callback id: 49 transmit status: OK 20:34:29.153 SERIAL « 0x010a00040018044005038823 (12 bytes) 20:34:29.154 CNTRLR [Node 024] [Thermostat Mode] mode: metadata updated [Endpoint 0] 20:34:29.155 CNTRLR [Node 024] [+] [Thermostat Mode] supportedModes: 0,1,1 [Endpoint 0] [internal] 1,15 20:34:29.155 SERIAL » [ACK] (0x06) 20:34:29.156 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ThermostatModeCCSupportedReport] supported modes: · Off · Heat · Energy heat · Full power 20:34:29.158 SERIAL » 0x010a00131a0370050325329e (12 bytes) 20:34:29.159 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 50 └─[ConfigurationCCGet] parameter #: 3 20:34:29.159 CNTRLR « [Node 024] received supported thermostat modes: · Off · Heat · Energy heat · Full power 20:34:29.159 CNTRLR » [Node 024] querying current thermostat mode... 20:34:29.161 SERIAL « [ACK] (0x06) 20:34:29.164 SERIAL « 0x0104011301e8 (6 bytes) 20:34:29.165 SERIAL » [ACK] (0x06) 20:34:29.165 DRIVER « [RES] [SendData] was sent: true 20:34:29.270 SERIAL « 0x010700133200000bd2 (9 bytes) 20:34:29.271 SERIAL » [ACK] (0x06) 20:34:29.271 DRIVER « [REQ] [SendData] callback id: 50 transmit status: OK 20:34:29.341 SERIAL « 0x010c0004001a067006030200009c (14 bytes) 20:34:29.343 CNTRLR [Node 026] [+] [Configuration] 3: 0 20:34:29.344 SERIAL » [ACK] (0x06) 20:34:29.345 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 2 value: 0 20:34:29.350 SERIAL » 0x010a00131c03700503253399 (12 bytes) 20:34:29.351 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 51 └─[ConfigurationCCGet] parameter #: 3 20:34:29.351 CNTRLR « [Node 026] parameter #3 has value: 0 20:34:29.351 CNTRLR » [Node 026] querying parameter #10 value... 20:34:29.355 SERIAL « [ACK] (0x06) 20:34:29.357 SERIAL « 0x0104011301e8 (6 bytes) 20:34:29.358 SERIAL » [ACK] (0x06) 20:34:29.359 DRIVER « [RES] [SendData] was sent: true 20:34:29.424 SERIAL « 0x0107001333000007df (9 bytes) 20:34:29.425 SERIAL » [ACK] (0x06) 20:34:29.425 DRIVER « [REQ] [SendData] callback id: 51 transmit status: OK 20:34:29.434 SERIAL « 0x010c0004001c067006030200009a (14 bytes) 20:34:29.436 CNTRLR [Node 028] [+] [Configuration] 3: 0 20:34:29.437 SERIAL » [ACK] (0x06) 20:34:29.438 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 2 value: 0 20:34:29.441 SERIAL » 0x010a0013030370050c25348e (12 bytes) 20:34:29.442 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 52 └─[ConfigurationCCGet] parameter #: 12 20:34:29.442 CNTRLR « [Node 028] parameter #3 has value: 0 20:34:29.442 CNTRLR » [Node 028] querying parameter #10 value... 20:34:29.446 SERIAL « [ACK] (0x06) 20:34:29.448 SERIAL « 0x0104011301e8 (6 bytes) 20:34:29.449 SERIAL » [ACK] (0x06) 20:34:29.450 DRIVER « [RES] [SendData] was sent: true 20:34:29.467 SERIAL « 0x0107001334000002dd (9 bytes) 20:34:29.467 SERIAL » [ACK] (0x06) 20:34:29.468 DRIVER « [REQ] [SendData] callback id: 52 transmit status: OK 20:34:29.480 SERIAL « 0x010c000400030670060c02001e94 (14 bytes) 20:34:29.482 CNTRLR [Node 003] [+] [Configuration] 12: 30 20:34:29.482 SERIAL » [ACK] (0x06) 20:34:29.483 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 30 20:34:29.486 SERIAL » 0x010a0013050370050825358d (12 bytes) 20:34:29.487 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 53 └─[ConfigurationCCGet] parameter #: 8 20:34:29.487 CNTRLR « [Node 003] parameter #12 has value: 30 20:34:29.487 CNTRLR » [Node 003] querying parameter #13 value... 20:34:29.491 SERIAL « [ACK] (0x06) 20:34:29.493 SERIAL « 0x0104011301e8 (6 bytes) 20:34:29.494 SERIAL » [ACK] (0x06) 20:34:29.495 DRIVER « [RES] [SendData] was sent: true 20:34:29.507 SERIAL « 0x0107001335000002dc (9 bytes) 20:34:29.508 SERIAL » [ACK] (0x06) 20:34:29.508 DRIVER « [REQ] [SendData] callback id: 53 transmit status: OK 20:34:29.517 SERIAL « 0x010c000400050670060802000088 (14 bytes) 20:34:29.518 CNTRLR [Node 005] [+] [Configuration] 8: 0 20:34:29.519 SERIAL » [ACK] (0x06) 20:34:29.520 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 2 value: 0 20:34:29.524 SERIAL » 0x010a0013060370050825368d (12 bytes) 20:34:29.524 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 54 └─[ConfigurationCCGet] parameter #: 8 20:34:29.524 CNTRLR « [Node 005] parameter #8 has value: 0 20:34:29.524 CNTRLR » [Node 005] querying parameter #9 value... 20:34:29.527 SERIAL « [ACK] (0x06) 20:34:29.530 SERIAL « 0x0104011301e8 (6 bytes) 20:34:29.530 SERIAL » [ACK] (0x06) 20:34:29.530 DRIVER « [RES] [SendData] was sent: true 20:34:29.544 SERIAL « 0x0107001336000002df (9 bytes) 20:34:29.544 SERIAL » [ACK] (0x06) 20:34:29.545 DRIVER « [REQ] [SendData] callback id: 54 transmit status: OK 20:34:29.555 SERIAL « 0x010c00040006067006080200008b (14 bytes) 20:34:29.556 CNTRLR [Node 006] [+] [Configuration] 8: 0 20:34:29.556 SERIAL » [ACK] (0x06) 20:34:29.557 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 2 value: 0 20:34:29.559 SERIAL » 0x010a00130203700502253782 (12 bytes) 20:34:29.560 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 55 └─[ConfigurationCCGet] parameter #: 2 20:34:29.560 CNTRLR « [Node 006] parameter #8 has value: 0 20:34:29.560 CNTRLR » [Node 006] querying parameter #9 value... 20:34:29.562 SERIAL « [ACK] (0x06) 20:34:29.571 SERIAL « 0x0104011301e8 (6 bytes) 20:34:29.571 SERIAL » [ACK] (0x06) 20:34:29.572 DRIVER « [RES] [SendData] was sent: true 20:34:29.584 SERIAL « 0x0107001337000002de (9 bytes) 20:34:29.584 SERIAL » [ACK] (0x06) 20:34:29.585 DRIVER « [REQ] [SendData] callback id: 55 transmit status: OK 20:34:29.608 SERIAL « 0x010c000400020670060202000683 (14 bytes) 20:34:29.609 CNTRLR [Node 002] [+] [Configuration] 2: 6 20:34:29.610 SERIAL » [ACK] (0x06) 20:34:29.610 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 2 value: 6 20:34:29.612 SERIAL » 0x010a0013130370050a253894 (12 bytes) 20:34:29.612 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 56 └─[ConfigurationCCGet] parameter #: 10 20:34:29.612 CNTRLR « [Node 002] parameter #2 has value: 6 20:34:29.612 CNTRLR » [Node 002] querying parameter #3 value... 20:34:29.614 SERIAL « [ACK] (0x06) 20:34:29.617 SERIAL « 0x0104011301e8 (6 bytes) 20:34:29.617 SERIAL » [ACK] (0x06) 20:34:29.618 DRIVER « [RES] [SendData] was sent: true 20:34:29.760 SERIAL « 0x010700133800000edd (9 bytes) 20:34:29.760 SERIAL » [ACK] (0x06) 20:34:29.761 DRIVER « [REQ] [SendData] callback id: 56 transmit status: OK 20:34:29.886 SERIAL « 0x010b000400130570060a0150cb (13 bytes) 20:34:29.888 CNTRLR [Node 019] [+] [Configuration] 10: 80 20:34:29.889 SERIAL » [ACK] (0x06) 20:34:29.890 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 80 20:34:29.895 SERIAL » 0x010a00131203700506253998 (12 bytes) 20:34:29.895 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 57 └─[ConfigurationCCGet] parameter #: 6 20:34:29.896 CNTRLR « [Node 019] parameter #10 has value: 80 20:34:29.896 CNTRLR » [Node 019] querying parameter #11 value... 20:34:29.899 SERIAL « [ACK] (0x06) 20:34:29.901 SERIAL « 0x0104011301e8 (6 bytes) 20:34:29.901 SERIAL » [ACK] (0x06) 20:34:29.902 DRIVER « [RES] [SendData] was sent: true 20:34:30.014 SERIAL « 0x010700133900000cde (9 bytes) 20:34:30.015 SERIAL » [ACK] (0x06) 20:34:30.015 DRIVER « [REQ] [SendData] callback id: 57 transmit status: OK 20:34:30.024 SERIAL « 0x010b0004001205700606010197 (13 bytes) 20:34:30.025 CNTRLR [Node 018] [+] [Configuration] 6: 1 20:34:30.026 SERIAL » [ACK] (0x06) 20:34:30.027 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 1 value: 1 20:34:30.030 SERIAL » 0x010a00131403320128253af5 (12 bytes) 20:34:30.031 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 58 └─[MeterCCGet] duration: A 20:34:30.031 CNTRLR « [Node 018] parameter #6 has value: 1 20:34:30.031 CNTRLR » [Node 018] querying parameter #7 value... 20:34:30.035 SERIAL « [ACK] (0x06) 20:34:30.036 SERIAL « 0x0104011301e8 (6 bytes) 20:34:30.037 SERIAL » [ACK] (0x06) 20:34:30.038 DRIVER « [RES] [SendData] was sent: true 20:34:30.056 SERIAL « 0x010700133a000002d3 (9 bytes) 20:34:30.056 SERIAL » [ACK] (0x06) 20:34:30.057 DRIVER « [REQ] [SendData] callback id: 58 transmit status: OK 20:34:30.085 SERIAL « 0x0110000400140a3202a14a0000000000002e (18 bytes) 20:34:30.086 CNTRLR [Node 020] [Meter] value[66817]: metadata updated [Endpoint 0] 20:34:30.087 CNTRLR [Node 020] [Meter] previousValue[66817]: metadata updated [Endpoint 0] 20:34:30.088 CNTRLR [Node 020] [Meter] deltaTime[66817]: metadata updated [Endpoint 0] 20:34:30.088 CNTRLR [Node 020] [+] [Meter] value[66817]: 0 [Endpoint 0] 20:34:30.089 CNTRLR [Node 020] [+] [Meter] deltaTime[66817]: 0 [Endpoint 0] 20:34:30.089 SERIAL » [ACK] (0x06) 20:34:30.091 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: A rate type: Consumed value: 0 time delta: 0 seconds 20:34:30.094 SERIAL » 0x0109001315024002253bae (11 bytes) 20:34:30.094 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 59 └─[ThermostatModeCCGet] 20:34:30.094 CNTRLR » [Node 020] querying meter value (type = Electric, scale = Power Factor)... 20:34:30.098 SERIAL « [ACK] (0x06) 20:34:30.100 SERIAL « 0x0104011301e8 (6 bytes) 20:34:30.101 SERIAL » [ACK] (0x06) 20:34:30.102 DRIVER « [RES] [SendData] was sent: true 20:34:31.500 SERIAL « 0x010700133b00008d5d (9 bytes) 20:34:31.501 SERIAL » [ACK] (0x06) 20:34:31.501 DRIVER « [REQ] [SendData] callback id: 59 transmit status: OK 20:34:31.579 SERIAL « 0x010a000400150440030000a3 (12 bytes) 20:34:31.581 CNTRLR [Node 021] [+] [Thermostat Mode] mode: 0 [Endpoint 0] 20:34:31.581 SERIAL » [ACK] (0x06) 20:34:31.582 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ThermostatModeCCReport] mode: Off 20:34:31.588 SERIAL » 0x0109001316024002253caa (11 bytes) 20:34:31.588 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 60 └─[ThermostatModeCCGet] 20:34:31.588 CNTRLR « [Node 021] received current thermostat mode: Off 20:34:31.589 CNTRLR [Node 021] [+] [Thermostat Mode] interviewComplete: tr [Endpoint 0] [internal] ue 20:34:31.594 SERIAL « [ACK] (0x06) 20:34:31.596 SERIAL « 0x0104011301e8 (6 bytes) 20:34:31.597 SERIAL » [ACK] (0x06) 20:34:31.597 DRIVER « [RES] [SendData] was sent: true 20:34:31.601 CNTRLR [Node 021] ThermostatSetpointCC: doing a complete interview... 20:34:31.601 CNTRLR » [Node 021] retrieving supported setpoint types... 20:34:33.067 SERIAL « 0x010700133c00009344 (9 bytes) 20:34:33.067 SERIAL » [ACK] (0x06) 20:34:33.068 DRIVER « [REQ] [SendData] callback id: 60 transmit status: OK 20:34:33.144 SERIAL « 0x010a000400160440030100a1 (12 bytes) 20:34:33.145 CNTRLR [Node 022] [+] [Thermostat Mode] mode: 1 [Endpoint 0] 20:34:33.145 SERIAL » [ACK] (0x06) 20:34:33.146 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ThermostatModeCCReport] mode: Heat 20:34:33.149 SERIAL » 0x0109001317024002253daa (11 bytes) 20:34:33.150 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 61 └─[ThermostatModeCCGet] 20:34:33.150 CNTRLR « [Node 022] received current thermostat mode: Heat 20:34:33.151 CNTRLR [Node 022] [+] [Thermostat Mode] interviewComplete: tr [Endpoint 0] [internal] ue 20:34:33.157 SERIAL « [ACK] (0x06) 20:34:33.160 SERIAL « 0x0104011301e8 (6 bytes) 20:34:33.160 SERIAL » [ACK] (0x06) 20:34:33.161 DRIVER « [RES] [SendData] was sent: true 20:34:33.163 CNTRLR [Node 022] ThermostatSetpointCC: doing a complete interview... 20:34:33.163 CNTRLR » [Node 022] retrieving supported setpoint types... 20:34:34.620 SERIAL « 0x010700133d00009345 (9 bytes) 20:34:34.620 SERIAL » [ACK] (0x06) 20:34:34.621 DRIVER « [REQ] [SendData] callback id: 61 transmit status: OK 20:34:34.697 SERIAL « 0x010a000400170440030100a0 (12 bytes) 20:34:34.698 CNTRLR [Node 023] [+] [Thermostat Mode] mode: 1 [Endpoint 0] 20:34:34.698 SERIAL » [ACK] (0x06) 20:34:34.699 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ThermostatModeCCReport] mode: Heat 20:34:34.701 SERIAL » 0x0109001318024002253ea6 (11 bytes) 20:34:34.701 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 62 └─[ThermostatModeCCGet] 20:34:34.701 CNTRLR « [Node 023] received current thermostat mode: Heat 20:34:34.702 CNTRLR [Node 023] [+] [Thermostat Mode] interviewComplete: tr [Endpoint 0] [internal] ue 20:34:34.704 SERIAL « [ACK] (0x06) 20:34:34.705 CNTRLR [Node 023] ThermostatSetpointCC: doing a complete interview... 20:34:34.706 CNTRLR » [Node 023] retrieving supported setpoint types... 20:34:34.708 SERIAL « 0x0104011301e8 (6 bytes) 20:34:34.708 SERIAL » [ACK] (0x06) 20:34:34.709 DRIVER « [RES] [SendData] was sent: true 20:34:36.168 SERIAL « 0x010c0004001a06310504220a19ea (14 bytes) 20:34:36.169 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:34:36.170 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 222.5 => 258.5 [Endpoint 0] 20:34:36.170 SERIAL » [ACK] (0x06) 20:34:36.172 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 258.5 20:34:36.177 SERIAL « 0x010700133e00009346 (9 bytes) 20:34:36.177 SERIAL » [ACK] (0x06) 20:34:36.178 DRIVER « [REQ] [SendData] callback id: 62 transmit status: OK 20:34:36.407 SERIAL « 0x010a000400180440030100af (12 bytes) 20:34:36.408 CNTRLR [Node 024] [+] [Thermostat Mode] mode: 1 [Endpoint 0] 20:34:36.409 SERIAL » [ACK] (0x06) 20:34:36.410 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ThermostatModeCCReport] mode: Heat 20:34:36.411 SERIAL » 0x010a00131a0370050a253f9a (12 bytes) 20:34:36.412 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 63 └─[ConfigurationCCGet] parameter #: 10 20:34:36.412 CNTRLR « [Node 024] received current thermostat mode: Heat 20:34:36.412 CNTRLR [Node 024] [+] [Thermostat Mode] interviewComplete: tr [Endpoint 0] [internal] ue 20:34:36.415 SERIAL « [ACK] (0x06) 20:34:36.416 CNTRLR [Node 024] ThermostatSetpointCC: doing a complete interview... 20:34:36.416 CNTRLR » [Node 024] retrieving supported setpoint types... 20:34:36.417 SERIAL « 0x0104011301e8 (6 bytes) 20:34:36.418 SERIAL » [ACK] (0x06) 20:34:36.418 DRIVER « [RES] [SendData] was sent: true 20:34:36.520 SERIAL « 0x010700133f00000ade (9 bytes) 20:34:36.520 SERIAL » [ACK] (0x06) 20:34:36.521 DRIVER « [REQ] [SendData] callback id: 63 transmit status: OK 20:34:36.591 SERIAL « 0x010b0004001a0570060a0150c2 (13 bytes) 20:34:36.593 CNTRLR [Node 026] [+] [Configuration] 10: 80 20:34:36.594 SERIAL » [ACK] (0x06) 20:34:36.595 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 80 20:34:36.598 SERIAL » 0x010a00131c0370050a2540e3 (12 bytes) 20:34:36.599 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 64 └─[ConfigurationCCGet] parameter #: 10 20:34:36.599 CNTRLR « [Node 026] parameter #10 has value: 80 20:34:36.599 CNTRLR » [Node 026] querying parameter #11 value... 20:34:36.603 SERIAL « [ACK] (0x06) 20:34:36.605 SERIAL « 0x0104011301e8 (6 bytes) 20:34:36.606 SERIAL » [ACK] (0x06) 20:34:36.612 DRIVER « [RES] [SendData] was sent: true 20:34:36.674 SERIAL « 0x0107001340000007ac (9 bytes) 20:34:36.675 SERIAL » [ACK] (0x06) 20:34:36.675 DRIVER « [REQ] [SendData] callback id: 64 transmit status: OK 20:34:36.686 SERIAL « 0x010b0004001c0570060a0150c4 (13 bytes) 20:34:36.691 CNTRLR [Node 028] [+] [Configuration] 10: 80 20:34:36.692 SERIAL » [ACK] (0x06) 20:34:36.693 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 80 20:34:36.700 SERIAL » 0x010a0013030370050d2541fa (12 bytes) 20:34:36.700 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 65 └─[ConfigurationCCGet] parameter #: 13 20:34:36.701 CNTRLR « [Node 028] parameter #10 has value: 80 20:34:36.701 CNTRLR » [Node 028] querying parameter #11 value... 20:34:36.705 SERIAL « [ACK] (0x06) 20:34:36.706 SERIAL « 0x0104011301e8 (6 bytes) 20:34:36.706 SERIAL » [ACK] (0x06) 20:34:36.707 DRIVER « [RES] [SendData] was sent: true 20:34:36.725 SERIAL « 0x0107001341000002a8 (9 bytes) 20:34:36.725 SERIAL » [ACK] (0x06) 20:34:36.725 DRIVER « [REQ] [SendData] callback id: 65 transmit status: OK 20:34:36.738 SERIAL « 0x010c000400030670060d02000a81 (14 bytes) 20:34:36.739 CNTRLR [Node 003] [+] [Configuration] 13: 10 20:34:36.739 SERIAL » [ACK] (0x06) 20:34:36.740 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 2 value: 10 20:34:36.741 SERIAL » 0x010a001305037005092542fb (12 bytes) 20:34:36.741 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 66 └─[ConfigurationCCGet] parameter #: 9 20:34:36.741 CNTRLR « [Node 003] parameter #13 has value: 10 20:34:36.741 CNTRLR » [Node 003] querying parameter #14 value... 20:34:36.742 SERIAL « [ACK] (0x06) 20:34:36.747 SERIAL « 0x0104011301e8 (6 bytes) 20:34:36.747 SERIAL » [ACK] (0x06) 20:34:36.747 DRIVER « [RES] [SendData] was sent: true 20:34:36.762 SERIAL « 0x0107001342000002ab (9 bytes) 20:34:36.762 SERIAL » [ACK] (0x06) 20:34:36.763 DRIVER « [REQ] [SendData] callback id: 66 transmit status: OK 20:34:36.772 SERIAL « 0x010b000400050570060901008e (13 bytes) 20:34:36.773 CNTRLR [Node 005] [+] [Configuration] 9: 0 20:34:36.773 SERIAL » [ACK] (0x06) 20:34:36.773 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 1 value: 0 20:34:36.774 SERIAL » 0x010a001306037005092543f9 (12 bytes) 20:34:36.775 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 67 └─[ConfigurationCCGet] parameter #: 9 20:34:36.775 CNTRLR « [Node 005] parameter #9 has value: 0 20:34:36.775 CNTRLR [Node 005] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 20:34:36.777 SERIAL « [ACK] (0x06) 20:34:36.780 CNTRLR [Node 005] MeterCC: doing a complete interview... 20:34:36.780 CNTRLR » [Node 005] querying meter support... 20:34:36.781 SERIAL « 0x0104011301e8 (6 bytes) 20:34:36.781 SERIAL » [ACK] (0x06) 20:34:36.781 DRIVER « [RES] [SendData] was sent: true 20:34:36.795 SERIAL « 0x0107001343000002aa (9 bytes) 20:34:36.795 SERIAL » [ACK] (0x06) 20:34:36.796 DRIVER « [REQ] [SendData] callback id: 67 transmit status: OK 20:34:36.805 SERIAL « 0x010b000400060570060901008d (13 bytes) 20:34:36.806 CNTRLR [Node 006] [+] [Configuration] 9: 0 20:34:36.807 SERIAL » [ACK] (0x06) 20:34:36.808 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 1 value: 0 20:34:36.811 SERIAL » 0x010a001302037005032544f0 (12 bytes) 20:34:36.811 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 68 └─[ConfigurationCCGet] parameter #: 3 20:34:36.812 CNTRLR « [Node 006] parameter #9 has value: 0 20:34:36.812 CNTRLR [Node 006] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 20:34:36.813 CNTRLR [Node 006] MeterCC: doing a complete interview... 20:34:36.813 CNTRLR » [Node 006] querying meter support... 20:34:36.817 SERIAL « [ACK] (0x06) 20:34:36.818 SERIAL « 0x0104011301e8 (6 bytes) 20:34:36.818 SERIAL » [ACK] (0x06) 20:34:36.819 DRIVER « [RES] [SendData] was sent: true 20:34:36.836 SERIAL « 0x0107001344000002ad (9 bytes) 20:34:36.837 SERIAL » [ACK] (0x06) 20:34:36.837 DRIVER « [REQ] [SendData] callback id: 68 transmit status: OK 20:34:36.861 SERIAL « 0x010c000400020670060302051495 (14 bytes) 20:34:36.861 CNTRLR [Node 002] [+] [Configuration] 3: 1300 20:34:36.862 SERIAL » [ACK] (0x06) 20:34:36.862 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 2 value: 1300 20:34:36.863 SERIAL » 0x010a0013130370050b2545e8 (12 bytes) 20:34:36.863 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 69 └─[ConfigurationCCGet] parameter #: 11 20:34:36.863 CNTRLR « [Node 002] parameter #3 has value: 1300 20:34:36.863 CNTRLR » [Node 002] querying parameter #4 value... 20:34:36.865 SERIAL « [ACK] (0x06) 20:34:36.877 SERIAL « 0x0104011301e8 (6 bytes) 20:34:36.877 SERIAL » [ACK] (0x06) 20:34:36.877 DRIVER « [RES] [SendData] was sent: true 20:34:37.011 SERIAL « 0x010700134500000fa1 (9 bytes) 20:34:37.011 SERIAL » [ACK] (0x06) 20:34:37.012 DRIVER « [REQ] [SendData] callback id: 69 transmit status: OK 20:34:37.136 SERIAL « 0x010b000400130570060b010f95 (13 bytes) 20:34:37.138 CNTRLR [Node 019] [+] [Configuration] 11: 15 20:34:37.139 SERIAL » [ACK] (0x06) 20:34:37.140 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 11 value size: 1 value: 15 20:34:37.143 SERIAL » 0x010a001312037005072546e6 (12 bytes) 20:34:37.143 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 70 └─[ConfigurationCCGet] parameter #: 7 20:34:37.143 CNTRLR « [Node 019] parameter #11 has value: 15 20:34:37.144 CNTRLR » [Node 019] querying parameter #12 value... 20:34:37.159 SERIAL « [ACK] (0x06) 20:34:37.161 SERIAL « 0x0104011301e8 (6 bytes) 20:34:37.162 SERIAL » [ACK] (0x06) 20:34:37.175 DRIVER « [RES] [SendData] was sent: true 20:34:37.264 SERIAL « 0x010700134600000ca1 (9 bytes) 20:34:37.265 SERIAL » [ACK] (0x06) 20:34:37.265 DRIVER « [REQ] [SendData] callback id: 70 transmit status: OK 20:34:37.274 SERIAL « 0x010b0004001205700607010196 (13 bytes) 20:34:37.276 CNTRLR [Node 018] [+] [Configuration] 7: 1 20:34:37.277 SERIAL » [ACK] (0x06) 20:34:37.279 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 7 value size: 1 value: 1 20:34:37.282 SERIAL » 0x010a00131403320130254790 (12 bytes) 20:34:37.283 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 71 └─[MeterCCGet] duration: Power Factor 20:34:37.283 CNTRLR « [Node 018] parameter #7 has value: 1 20:34:37.283 CNTRLR » [Node 018] querying parameter #8 value... 20:34:37.287 SERIAL « [ACK] (0x06) 20:34:37.289 SERIAL « 0x0104011301e8 (6 bytes) 20:34:37.289 SERIAL » [ACK] (0x06) 20:34:37.291 DRIVER « [RES] [SendData] was sent: true 20:34:37.308 SERIAL « 0x0107001347000002ae (9 bytes) 20:34:37.308 SERIAL » [ACK] (0x06) 20:34:37.309 DRIVER « [REQ] [SendData] callback id: 71 transmit status: OK 20:34:37.337 SERIAL « 0x010e00040014083202a1510000000029 (16 bytes) 20:34:37.338 CNTRLR [Node 020] [Meter] value[67073]: metadata updated [Endpoint 0] 20:34:37.339 CNTRLR [Node 020] [Meter] previousValue[67073]: metadata updated [Endpoint 0] 20:34:37.340 CNTRLR [Node 020] [Meter] deltaTime[67073]: metadata updated [Endpoint 0] 20:34:37.341 CNTRLR [Node 020] [+] [Meter] value[67073]: 0 [Endpoint 0] 20:34:37.341 CNTRLR [Node 020] [+] [Meter] deltaTime[67073]: 0 [Endpoint 0] 20:34:37.342 SERIAL » [ACK] (0x06) 20:34:37.343 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: Power Factor rate type: Consumed value: 0 time delta: 0 seconds 20:34:37.346 SERIAL » 0x01090013150243042548d8 (11 bytes) 20:34:37.346 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 72 └─[ThermostatSetpointCCSupportedGet] 20:34:37.347 CNTRLR [Node 020] [+] [Meter] interviewComplete: true [Endpoint 0] [internal] 20:34:37.354 SERIAL « [ACK] (0x06) 20:34:37.356 SERIAL « 0x0104011301e8 (6 bytes) 20:34:37.356 SERIAL » [ACK] (0x06) 20:34:37.357 DRIVER « [RES] [SendData] was sent: true 20:34:37.361 CNTRLR [Node 020] ConfigurationCC: Loading configuration parameters from device confi g 20:34:37.362 CNTRLR [Node 020] [+] [Configuration] isParamInformationFromConfig: false [internal] 20:34:37.363 CNTRLR [Node 020] [Configuration] 1: metadata updated 20:34:37.364 CNTRLR [Node 020] [Configuration] 2: metadata updated 20:34:37.365 CNTRLR [Node 020] [Configuration] 3: metadata updated 20:34:37.366 CNTRLR [Node 020] [Configuration] 4: metadata updated 20:34:37.367 CNTRLR [Node 020] [Configuration] 5: metadata updated 20:34:37.367 CNTRLR [Node 020] [Configuration] 6: metadata updated 20:34:37.368 CNTRLR [Node 020] [Configuration] 7: metadata updated 20:34:37.369 CNTRLR [Node 020] [Configuration] 8: metadata updated 20:34:37.370 CNTRLR [Node 020] [Configuration] 9: metadata updated 20:34:37.370 CNTRLR [Node 020] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 20:34:37.370 CNTRLR » [Node 020] querying parameter #1 value... 20:34:38.753 SERIAL « 0x010700134800008d2e (9 bytes) 20:34:38.753 SERIAL » [ACK] (0x06) 20:34:38.753 DRIVER « [REQ] [SendData] callback id: 72 transmit status: OK 20:34:38.834 SERIAL « 0x010a00040015044305820024 (12 bytes) 20:34:38.836 CNTRLR [Node 021] [+] [Thermostat Setpoint] supportedSetpoint [Endpoint 0] [internal] Types: 1,11 20:34:38.836 SERIAL » [ACK] (0x06) 20:34:38.837 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCSupportedReport] supported setpoint types: · Heating · Energy Save Heating 20:34:38.839 SERIAL » 0x01090013160243042549da (11 bytes) 20:34:38.839 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 73 └─[ThermostatSetpointCCSupportedGet] 20:34:38.839 CNTRLR « [Node 021] received supported setpoint types: · Heating · Energy Save Heating 20:34:38.839 CNTRLR » [Node 021] retrieving capabilities for setpoint Heating... 20:34:38.841 SERIAL « [ACK] (0x06) 20:34:38.845 SERIAL « 0x0104011301e8 (6 bytes) 20:34:38.845 SERIAL » [ACK] (0x06) 20:34:38.846 DRIVER « [RES] [SendData] was sent: true 20:34:40.326 SERIAL « 0x010700134900009436 (9 bytes) 20:34:40.327 SERIAL » [ACK] (0x06) 20:34:40.327 DRIVER « [REQ] [SendData] callback id: 73 transmit status: OK 20:34:40.407 SERIAL « 0x010a00040016044305820027 (12 bytes) 20:34:40.408 CNTRLR [Node 022] [+] [Thermostat Setpoint] supportedSetpoint [Endpoint 0] [internal] Types: 1,11 20:34:40.409 SERIAL » [ACK] (0x06) 20:34:40.409 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCSupportedReport] supported setpoint types: · Heating · Energy Save Heating 20:34:40.414 SERIAL » 0x0109001317024304254ad8 (11 bytes) 20:34:40.414 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 74 └─[ThermostatSetpointCCSupportedGet] 20:34:40.414 CNTRLR « [Node 022] received supported setpoint types: · Heating · Energy Save Heating 20:34:40.414 CNTRLR » [Node 022] retrieving capabilities for setpoint Heating... 20:34:40.415 SERIAL « [ACK] (0x06) 20:34:40.419 SERIAL « 0x0104011301e8 (6 bytes) 20:34:40.419 SERIAL » [ACK] (0x06) 20:34:40.419 DRIVER « [RES] [SendData] was sent: true 20:34:41.828 SERIAL « 0x010700134a00008d2c (9 bytes) 20:34:41.828 SERIAL » [ACK] (0x06) 20:34:41.829 DRIVER « [REQ] [SendData] callback id: 74 transmit status: OK 20:34:41.912 SERIAL « 0x010a00040017044305820026 (12 bytes) 20:34:41.913 CNTRLR [Node 023] [+] [Thermostat Setpoint] supportedSetpoint [Endpoint 0] [internal] Types: 1,11 20:34:41.914 SERIAL » [ACK] (0x06) 20:34:41.914 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCSupportedReport] supported setpoint types: · Heating · Energy Save Heating 20:34:41.917 SERIAL » 0x0109001318024304254bd6 (11 bytes) 20:34:41.917 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 75 └─[ThermostatSetpointCCSupportedGet] 20:34:41.918 CNTRLR « [Node 023] received supported setpoint types: · Heating · Energy Save Heating 20:34:41.918 CNTRLR » [Node 023] retrieving capabilities for setpoint Heating... 20:34:41.921 SERIAL « [ACK] (0x06) 20:34:41.924 SERIAL « 0x0104011301e8 (6 bytes) 20:34:41.924 SERIAL » [ACK] (0x06) 20:34:41.925 DRIVER « [RES] [SendData] was sent: true 20:34:43.320 SERIAL « 0x010700134b00008b2b (9 bytes) 20:34:43.320 SERIAL » [ACK] (0x06) 20:34:43.321 DRIVER « [REQ] [SendData] callback id: 75 transmit status: OK 20:34:43.402 SERIAL « 0x010a00040018044305820029 (12 bytes) 20:34:43.402 CNTRLR [Node 024] [+] [Thermostat Setpoint] supportedSetpoint [Endpoint 0] [internal] Types: 1,11 20:34:43.402 SERIAL » [ACK] (0x06) 20:34:43.402 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCSupportedReport] supported setpoint types: · Heating · Energy Save Heating 20:34:43.403 SERIAL » 0x010a00131a0370050b254ce8 (12 bytes) 20:34:43.404 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 76 └─[ConfigurationCCGet] parameter #: 11 20:34:43.404 CNTRLR « [Node 024] received supported setpoint types: · Heating · Energy Save Heating 20:34:43.404 CNTRLR » [Node 024] retrieving capabilities for setpoint Heating... 20:34:43.406 SERIAL « [ACK] (0x06) 20:34:43.409 SERIAL « 0x0104011301e8 (6 bytes) 20:34:43.409 SERIAL » [ACK] (0x06) 20:34:43.409 DRIVER « [RES] [SendData] was sent: true 20:34:43.510 SERIAL « 0x010700134c00000bac (9 bytes) 20:34:43.511 SERIAL » [ACK] (0x06) 20:34:43.511 DRIVER « [REQ] [SendData] callback id: 76 transmit status: OK 20:34:43.581 SERIAL « 0x010b0004001a0570060b010f9c (13 bytes) 20:34:43.583 CNTRLR [Node 026] [+] [Configuration] 11: 15 20:34:43.584 SERIAL » [ACK] (0x06) 20:34:43.584 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 11 value size: 1 value: 15 20:34:43.587 SERIAL » 0x010a00131c0370050b254def (12 bytes) 20:34:43.588 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 77 └─[ConfigurationCCGet] parameter #: 11 20:34:43.588 CNTRLR « [Node 026] parameter #11 has value: 15 20:34:43.588 CNTRLR » [Node 026] querying parameter #12 value... 20:34:43.592 SERIAL « [ACK] (0x06) 20:34:43.594 SERIAL « 0x0104011301e8 (6 bytes) 20:34:43.594 SERIAL » [ACK] (0x06) 20:34:43.595 DRIVER « [RES] [SendData] was sent: true 20:34:43.664 SERIAL « 0x010700134d000007a1 (9 bytes) 20:34:43.665 SERIAL » [ACK] (0x06) 20:34:43.665 DRIVER « [REQ] [SendData] callback id: 77 transmit status: OK 20:34:43.674 SERIAL « 0x010b0004001c0570060b010f9a (13 bytes) 20:34:43.676 CNTRLR [Node 028] [+] [Configuration] 11: 15 20:34:43.677 SERIAL » [ACK] (0x06) 20:34:43.677 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 11 value size: 1 value: 15 20:34:43.680 SERIAL » 0x010a0013030370050e254ef6 (12 bytes) 20:34:43.681 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 78 └─[ConfigurationCCGet] parameter #: 14 20:34:43.681 CNTRLR « [Node 028] parameter #11 has value: 15 20:34:43.681 CNTRLR » [Node 028] querying parameter #12 value... 20:34:43.685 SERIAL « [ACK] (0x06) 20:34:43.687 SERIAL « 0x0104011301e8 (6 bytes) 20:34:43.687 SERIAL » [ACK] (0x06) 20:34:43.688 DRIVER « [RES] [SendData] was sent: true 20:34:43.706 SERIAL « 0x010700134e000002a7 (9 bytes) 20:34:43.706 SERIAL » [ACK] (0x06) 20:34:43.707 DRIVER « [REQ] [SendData] callback id: 78 transmit status: OK 20:34:43.718 SERIAL « 0x010c000400030670060e020e1096 (14 bytes) 20:34:43.720 CNTRLR [Node 003] [+] [Configuration] 14: 3600 20:34:43.721 SERIAL » [ACK] (0x06) 20:34:43.722 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 2 value: 3600 20:34:43.724 SERIAL » 0x0109001305023203254fb9 (11 bytes) 20:34:43.725 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 79 └─[MeterCCSupportedGet] 20:34:43.725 CNTRLR « [Node 003] parameter #14 has value: 3600 20:34:43.725 CNTRLR » [Node 003] querying parameter #15 value... 20:34:43.729 SERIAL « [ACK] (0x06) 20:34:43.730 SERIAL « 0x0104011301e8 (6 bytes) 20:34:43.731 SERIAL » [ACK] (0x06) 20:34:43.732 DRIVER « [RES] [SendData] was sent: true 20:34:43.745 SERIAL « 0x010700134f000002a6 (9 bytes) 20:34:43.746 SERIAL » [ACK] (0x06) 20:34:43.746 DRIVER « [REQ] [SendData] callback id: 79 transmit status: OK 20:34:43.755 SERIAL « 0x010c00040005063204a1ff01039e (14 bytes) 20:34:43.757 CNTRLR [Node 005] [+] [Meter] type: 1 [Endpoint 0] [internal] 20:34:43.758 CNTRLR [Node 005] [+] [Meter] supportsReset: true [Endpoint 0] [internal] 20:34:43.758 CNTRLR [Node 005] [+] [Meter] supportedScales: 0,1,2,3,4,5,6, [Endpoint 0] [internal] 7,8 20:34:43.759 CNTRLR [Node 005] [+] [Meter] supportedRateTypes: 1 [Endpoint 0] [internal] 20:34:43.759 CNTRLR [Node 005] [Meter] reset: metadata updated [Endpoint 0] 20:34:43.760 SERIAL » [ACK] (0x06) 20:34:43.761 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCSupportedReport] type: Electric supports reset: true supported scales: · kWh · kVAh · W · Pulse count · V · A · Power Factor · kVar · kVarh supported rate types: Consumed 20:34:43.764 SERIAL » 0x01090013060232032550a5 (11 bytes) 20:34:43.765 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 80 └─[MeterCCSupportedGet] 20:34:43.769 CNTRLR « [Node 005] received meter support: type: Electric supported scales: · kWh · kVAh · W · Pulse count · V · A · Power Factor · kVar · kVarh supported rate types: · Consumed supports reset: true 20:34:43.769 CNTRLR » [Node 005] querying meter value (type = Electric, scale = kWh, rate type = Con sumed)... 20:34:43.772 SERIAL « [ACK] (0x06) 20:34:43.773 SERIAL « 0x0104011301e8 (6 bytes) 20:34:43.773 SERIAL » [ACK] (0x06) 20:34:43.774 DRIVER « [RES] [SendData] was sent: true 20:34:43.785 SERIAL « 0x0107001350000002b9 (9 bytes) 20:34:43.786 SERIAL » [ACK] (0x06) 20:34:43.786 DRIVER « [REQ] [SendData] callback id: 80 transmit status: OK 20:34:43.795 SERIAL « 0x010c00040006063204a1ff01039d (14 bytes) 20:34:43.796 CNTRLR [Node 006] [+] [Meter] type: 1 [Endpoint 0] [internal] 20:34:43.796 CNTRLR [Node 006] [+] [Meter] supportsReset: true [Endpoint 0] [internal] 20:34:43.796 CNTRLR [Node 006] [+] [Meter] supportedScales: 0,1,2,3,4,5,6, [Endpoint 0] [internal] 7,8 20:34:43.796 CNTRLR [Node 006] [+] [Meter] supportedRateTypes: 1 [Endpoint 0] [internal] 20:34:43.796 CNTRLR [Node 006] [Meter] reset: metadata updated [Endpoint 0] 20:34:43.797 SERIAL » [ACK] (0x06) 20:34:43.797 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCSupportedReport] type: Electric supports reset: true supported scales: · kWh · kVAh · W · Pulse count · V · A · Power Factor · kVar · kVarh supported rate types: Consumed 20:34:43.799 SERIAL » 0x010a001302037005042551e2 (12 bytes) 20:34:43.799 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 81 └─[ConfigurationCCGet] parameter #: 4 20:34:43.799 CNTRLR « [Node 006] received meter support: type: Electric supported scales: · kWh · kVAh · W · Pulse count · V · A · Power Factor · kVar · kVarh supported rate types: · Consumed supports reset: true 20:34:43.800 CNTRLR » [Node 006] querying meter value (type = Electric, scale = kWh, rate type = Con sumed)... 20:34:43.801 SERIAL « [ACK] (0x06) 20:34:43.804 SERIAL « 0x0104011301e8 (6 bytes) 20:34:43.805 SERIAL » [ACK] (0x06) 20:34:43.805 DRIVER « [RES] [SendData] was sent: true 20:34:43.824 SERIAL « 0x0107001351000002b8 (9 bytes) 20:34:43.824 SERIAL » [ACK] (0x06) 20:34:43.825 DRIVER « [REQ] [SendData] callback id: 81 transmit status: OK 20:34:43.848 SERIAL « 0x010c0004000206700604022710b4 (14 bytes) 20:34:43.850 CNTRLR [Node 002] [+] [Configuration] 4: 10000 20:34:43.851 SERIAL » [ACK] (0x06) 20:34:43.852 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 2 value: 10000 20:34:43.855 SERIAL » 0x010a0013130370050c2552f8 (12 bytes) 20:34:43.855 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 82 └─[ConfigurationCCGet] parameter #: 12 20:34:43.856 CNTRLR « [Node 002] parameter #4 has value: 10000 20:34:43.856 CNTRLR » [Node 002] querying parameter #5 value... 20:34:43.860 SERIAL « [ACK] (0x06) 20:34:43.862 SERIAL « 0x0104011301e8 (6 bytes) 20:34:43.862 SERIAL » [ACK] (0x06) 20:34:43.863 DRIVER « [RES] [SendData] was sent: true 20:34:44.002 SERIAL « 0x010700135200000fb6 (9 bytes) 20:34:44.003 SERIAL » [ACK] (0x06) 20:34:44.004 DRIVER « [REQ] [SendData] callback id: 82 transmit status: OK 20:34:44.138 SERIAL « 0x010c000400130670060c02001e84 (14 bytes) 20:34:44.140 CNTRLR [Node 019] [+] [Configuration] 12: 30 20:34:44.141 SERIAL » [ACK] (0x06) 20:34:44.141 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 30 20:34:44.143 SERIAL » 0x010a001312037005082553fc (12 bytes) 20:34:44.143 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 83 └─[ConfigurationCCGet] parameter #: 8 20:34:44.143 CNTRLR « [Node 019] parameter #12 has value: 30 20:34:44.143 CNTRLR » [Node 019] querying parameter #13 value... 20:34:44.145 SERIAL « [ACK] (0x06) 20:34:44.148 SERIAL « 0x0104011301e8 (6 bytes) 20:34:44.148 SERIAL » [ACK] (0x06) 20:34:44.149 DRIVER « [RES] [SendData] was sent: true 20:34:44.264 SERIAL « 0x010700135300000cb4 (9 bytes) 20:34:44.265 SERIAL » [ACK] (0x06) 20:34:44.265 DRIVER « [REQ] [SendData] callback id: 83 transmit status: OK 20:34:44.274 SERIAL « 0x010c00040012067006080200009f (14 bytes) 20:34:44.276 CNTRLR [Node 018] [+] [Configuration] 8: 0 20:34:44.276 SERIAL » [ACK] (0x06) 20:34:44.277 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 2 value: 0 20:34:44.280 SERIAL » 0x010a001314037005012554f4 (12 bytes) 20:34:44.280 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 84 └─[ConfigurationCCGet] parameter #: 1 20:34:44.281 CNTRLR « [Node 018] parameter #8 has value: 0 20:34:44.281 CNTRLR » [Node 018] querying parameter #9 value... 20:34:44.284 SERIAL « [ACK] (0x06) 20:34:44.286 SERIAL « 0x0104011301e8 (6 bytes) 20:34:44.286 SERIAL » [ACK] (0x06) 20:34:44.287 DRIVER « [RES] [SendData] was sent: true 20:34:44.305 SERIAL « 0x0107001354000002bd (9 bytes) 20:34:44.306 SERIAL » [ACK] (0x06) 20:34:44.306 DRIVER « [REQ] [SendData] callback id: 84 transmit status: OK 20:34:44.329 SERIAL « 0x010c00040014067006010202d042 (14 bytes) 20:34:44.331 CNTRLR [Node 020] [+] [Configuration] 1: 720 20:34:44.332 SERIAL » [ACK] (0x06) 20:34:44.332 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 2 value: 720 20:34:44.336 SERIAL » 0x010a001315034309012555cb (12 bytes) 20:34:44.336 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 85 └─[ThermostatSetpointCCCapabilitiesGet] setpoint type: Heating 20:34:44.336 CNTRLR « [Node 020] parameter #1 has value: 720 20:34:44.337 CNTRLR » [Node 020] querying parameter #2 value... 20:34:44.340 SERIAL « [ACK] (0x06) 20:34:44.342 SERIAL « 0x0104011301e8 (6 bytes) 20:34:44.343 SERIAL » [ACK] (0x06) 20:34:44.344 DRIVER « [RES] [SendData] was sent: true 20:34:45.726 SERIAL « 0x010700135500008b35 (9 bytes) 20:34:45.726 SERIAL » [ACK] (0x06) 20:34:45.727 DRIVER « [REQ] [SendData] callback id: 85 transmit status: OK 20:34:45.804 SERIAL « 0x010f0004001509430a01220050220118e9 (17 bytes) 20:34:45.806 CNTRLR [Node 021] [Thermostat Setpoint] setpoint[1]: metadata updated [Endpoint 0] 20:34:45.807 SERIAL » [ACK] (0x06) 20:34:45.808 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCCapabilitiesReport] setpoint type: Heating min value: 8 °C max value: 28 °C 20:34:45.810 SERIAL » 0x010a001316034309012556cb (12 bytes) 20:34:45.811 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 86 └─[ThermostatSetpointCCCapabilitiesGet] setpoint type: Heating 20:34:45.811 CNTRLR « [Node 021] received capabilities for setpoint Heating: minimum value: 8 °C maximum value: 28 °C 20:34:45.811 CNTRLR » [Node 021] querying current value of setpoint Heating... 20:34:45.812 SERIAL « [ACK] (0x06) 20:34:45.816 SERIAL « 0x0104011301e8 (6 bytes) 20:34:45.816 SERIAL » [ACK] (0x06) 20:34:45.816 DRIVER « [RES] [SendData] was sent: true 20:34:47.316 SERIAL « 0x01070013560000962b (9 bytes) 20:34:47.316 SERIAL » [ACK] (0x06) 20:34:47.317 DRIVER « [REQ] [SendData] callback id: 86 transmit status: OK 20:34:47.397 SERIAL « 0x010f0004001609430a01220050220118ea (17 bytes) 20:34:47.398 CNTRLR [Node 022] [Thermostat Setpoint] setpoint[1]: metadata updated [Endpoint 0] 20:34:47.398 SERIAL » [ACK] (0x06) 20:34:47.399 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCCapabilitiesReport] setpoint type: Heating min value: 8 °C max value: 28 °C 20:34:47.402 SERIAL » 0x010a001317034309012557cb (12 bytes) 20:34:47.403 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 87 └─[ThermostatSetpointCCCapabilitiesGet] setpoint type: Heating 20:34:47.403 CNTRLR « [Node 022] received capabilities for setpoint Heating: minimum value: 8 °C maximum value: 28 °C 20:34:47.403 CNTRLR » [Node 022] querying current value of setpoint Heating... 20:34:47.406 SERIAL « [ACK] (0x06) 20:34:47.408 SERIAL « 0x0104011301e8 (6 bytes) 20:34:47.409 SERIAL » [ACK] (0x06) 20:34:47.409 DRIVER « [RES] [SendData] was sent: true 20:34:48.872 SERIAL « 0x01070013570000932f (9 bytes) 20:34:48.872 SERIAL » [ACK] (0x06) 20:34:48.873 DRIVER « [REQ] [SendData] callback id: 87 transmit status: OK 20:34:48.955 SERIAL « 0x010f0004001709430a01220050220118eb (17 bytes) 20:34:48.956 CNTRLR [Node 023] [Thermostat Setpoint] setpoint[1]: metadata updated [Endpoint 0] 20:34:48.957 SERIAL » [ACK] (0x06) 20:34:48.958 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCCapabilitiesReport] setpoint type: Heating min value: 8 °C max value: 28 °C 20:34:48.961 SERIAL » 0x010a001318034309012558cb (12 bytes) 20:34:48.961 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 88 └─[ThermostatSetpointCCCapabilitiesGet] setpoint type: Heating 20:34:48.961 CNTRLR « [Node 023] received capabilities for setpoint Heating: minimum value: 8 °C maximum value: 28 °C 20:34:48.961 CNTRLR » [Node 023] querying current value of setpoint Heating... 20:34:48.963 SERIAL « [ACK] (0x06) 20:34:48.966 SERIAL « 0x0104011301e8 (6 bytes) 20:34:48.967 SERIAL » [ACK] (0x06) 20:34:48.967 DRIVER « [RES] [SendData] was sent: true 20:34:50.432 SERIAL « 0x010700135800009320 (9 bytes) 20:34:50.432 SERIAL » [ACK] (0x06) 20:34:50.433 DRIVER « [REQ] [SendData] callback id: 88 transmit status: OK 20:34:50.514 SERIAL « 0x010f0004001809430a01220050220118e4 (17 bytes) 20:34:50.515 CNTRLR [Node 024] [Thermostat Setpoint] setpoint[1]: metadata updated [Endpoint 0] 20:34:50.516 SERIAL » [ACK] (0x06) 20:34:50.516 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCCapabilitiesReport] setpoint type: Heating min value: 8 °C max value: 28 °C 20:34:50.521 SERIAL » 0x010a00131a0370050c2559fa (12 bytes) 20:34:50.521 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 89 └─[ConfigurationCCGet] parameter #: 12 20:34:50.521 CNTRLR « [Node 024] received capabilities for setpoint Heating: minimum value: 8 °C maximum value: 28 °C 20:34:50.522 CNTRLR » [Node 024] querying current value of setpoint Heating... 20:34:50.523 SERIAL « [ACK] (0x06) 20:34:50.526 SERIAL « 0x0104011301e8 (6 bytes) 20:34:50.526 SERIAL » [ACK] (0x06) 20:34:50.526 DRIVER « [RES] [SendData] was sent: true 20:34:50.630 SERIAL « 0x010700135900000bb9 (9 bytes) 20:34:50.630 SERIAL » [ACK] (0x06) 20:34:50.631 DRIVER « [REQ] [SendData] callback id: 89 transmit status: OK 20:34:50.702 SERIAL « 0x010c0004001a0670060c02001e8d (14 bytes) 20:34:50.703 CNTRLR [Node 026] [+] [Configuration] 12: 30 20:34:50.704 SERIAL » [ACK] (0x06) 20:34:50.705 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 30 20:34:50.708 SERIAL » 0x010a00131c0370050c255aff (12 bytes) 20:34:50.708 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 90 └─[ConfigurationCCGet] parameter #: 12 20:34:50.708 CNTRLR « [Node 026] parameter #12 has value: 30 20:34:50.709 CNTRLR » [Node 026] querying parameter #13 value... 20:34:50.712 SERIAL « [ACK] (0x06) 20:34:50.715 SERIAL « 0x0104011301e8 (6 bytes) 20:34:50.715 SERIAL » [ACK] (0x06) 20:34:50.715 DRIVER « [RES] [SendData] was sent: true 20:34:50.784 SERIAL « 0x010700135a000007b6 (9 bytes) 20:34:50.784 SERIAL » [ACK] (0x06) 20:34:50.785 DRIVER « [REQ] [SendData] callback id: 90 transmit status: OK 20:34:50.794 SERIAL « 0x010c0004001c0670060c02001e8b (14 bytes) 20:34:50.796 CNTRLR [Node 028] [+] [Configuration] 12: 30 20:34:50.796 SERIAL » [ACK] (0x06) 20:34:50.797 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 30 20:34:50.799 SERIAL » 0x010a0013030370050f255be2 (12 bytes) 20:34:50.800 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 91 └─[ConfigurationCCGet] parameter #: 15 20:34:50.800 CNTRLR « [Node 028] parameter #12 has value: 30 20:34:50.800 CNTRLR » [Node 028] querying parameter #13 value... 20:34:50.803 SERIAL « [ACK] (0x06) 20:34:50.806 SERIAL « 0x0104011301e8 (6 bytes) 20:34:50.806 SERIAL » [ACK] (0x06) 20:34:50.806 DRIVER « [RES] [SendData] was sent: true 20:34:50.825 SERIAL « 0x010700135b000002b2 (9 bytes) 20:34:50.825 SERIAL » [ACK] (0x06) 20:34:50.825 DRIVER « [REQ] [SendData] callback id: 91 transmit status: OK 20:34:50.837 SERIAL « 0x010b000400030570060f01008e (13 bytes) 20:34:50.838 CNTRLR [Node 003] [+] [Configuration] 15: 0 20:34:50.839 SERIAL » [ACK] (0x06) 20:34:50.839 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 15 value size: 1 value: 0 20:34:50.840 SERIAL » 0x010a00130503320140255cea (12 bytes) 20:34:50.841 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 92 └─[MeterCCGet] rate type: Consumed duration: kWh 20:34:50.841 CNTRLR « [Node 003] parameter #15 has value: 0 20:34:50.841 CNTRLR » [Node 003] querying parameter #20 value... 20:34:50.843 SERIAL « [ACK] (0x06) 20:34:50.846 SERIAL « 0x0104011301e8 (6 bytes) 20:34:50.846 SERIAL » [ACK] (0x06) 20:34:50.847 DRIVER « [RES] [SendData] was sent: true 20:34:50.862 SERIAL « 0x010700135c000002b5 (9 bytes) 20:34:50.862 SERIAL » [ACK] (0x06) 20:34:50.862 DRIVER « [REQ] [SendData] callback id: 92 transmit status: OK 20:34:50.873 SERIAL « 0x0114000400050e320221440000019d00ee0000019d5f (22 bytes) 20:34:50.874 CNTRLR [Node 005] [Meter] previousValue[65537]: metadata updated [Endpoint 0] 20:34:50.874 CNTRLR [Node 005] [Meter] deltaTime[65537]: metadata updated [Endpoint 0] 20:34:50.875 CNTRLR [Node 005] [~] [Meter] value[65537]: 4.13 => 4.13 [Endpoint 0] 20:34:50.875 CNTRLR [Node 005] [+] [Meter] previousValue[65537]: 4.13 [Endpoint 0] 20:34:50.875 CNTRLR [Node 005] [~] [Meter] deltaTime[65537]: 0 => 238 [Endpoint 0] 20:34:50.876 SERIAL » [ACK] (0x06) 20:34:50.877 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 4.13 time delta: 238 seconds prev. value: 4.13 20:34:50.878 SERIAL » 0x010a00130603320140255de8 (12 bytes) 20:34:50.879 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 93 └─[MeterCCGet] rate type: Consumed duration: kWh 20:34:50.879 CNTRLR » [Node 005] querying meter value (type = Electric, scale = kVAh, rate type = Co nsumed)... 20:34:50.882 SERIAL « [ACK] (0x06) 20:34:50.886 SERIAL « 0x0104011301e8 (6 bytes) 20:34:50.886 SERIAL » [ACK] (0x06) 20:34:50.886 DRIVER « [RES] [SendData] was sent: true 20:34:50.899 SERIAL « 0x010700135d000001b7 (9 bytes) 20:34:50.899 SERIAL » [ACK] (0x06) 20:34:50.900 DRIVER « [REQ] [SendData] callback id: 93 transmit status: OK 20:34:50.910 SERIAL « 0x0114000400060e3202214400000028015200000028e1 (22 bytes) 20:34:50.911 CNTRLR [Node 006] [Meter] value[65537]: metadata updated [Endpoint 0] 20:34:50.911 CNTRLR [Node 006] [Meter] previousValue[65537]: metadata updated [Endpoint 0] 20:34:50.912 CNTRLR [Node 006] [Meter] deltaTime[65537]: metadata updated [Endpoint 0] 20:34:50.912 CNTRLR [Node 006] [+] [Meter] value[65537]: 0.4 [Endpoint 0] 20:34:50.913 CNTRLR [Node 006] [+] [Meter] previousValue[65537]: 0.4 [Endpoint 0] 20:34:50.913 CNTRLR [Node 006] [+] [Meter] deltaTime[65537]: 338 [Endpoint 0] 20:34:50.913 SERIAL » [ACK] (0x06) 20:34:50.915 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 0.4 time delta: 338 seconds prev. value: 0.4 20:34:50.917 SERIAL » 0x010a00130203700505255eec (12 bytes) 20:34:50.918 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 94 └─[ConfigurationCCGet] parameter #: 5 20:34:50.918 CNTRLR » [Node 006] querying meter value (type = Electric, scale = kVAh, rate type = Co nsumed)... 20:34:50.922 SERIAL « [ACK] (0x06) 20:34:50.923 SERIAL « 0x0104011301e8 (6 bytes) 20:34:50.924 SERIAL » [ACK] (0x06) 20:34:50.925 DRIVER « [RES] [SendData] was sent: true 20:34:50.942 SERIAL « 0x010700135e000003b6 (9 bytes) 20:34:50.944 SERIAL » [ACK] (0x06) 20:34:50.944 DRIVER « [REQ] [SendData] callback id: 94 transmit status: OK 20:34:50.966 SERIAL « 0x010b0004000205700605010184 (13 bytes) 20:34:50.968 CNTRLR [Node 002] [+] [Configuration] 5: 1 20:34:50.969 SERIAL » [ACK] (0x06) 20:34:50.970 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 1 value: 1 20:34:50.977 SERIAL » 0x010a0013130370050d255ff4 (12 bytes) 20:34:50.978 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 95 └─[ConfigurationCCGet] parameter #: 13 20:34:50.978 CNTRLR « [Node 002] parameter #5 has value: 1 20:34:50.978 CNTRLR » [Node 002] querying parameter #6 value... 20:34:50.982 SERIAL « [ACK] (0x06) 20:34:50.984 SERIAL « 0x0104011301e8 (6 bytes) 20:34:50.985 SERIAL » [ACK] (0x06) 20:34:50.985 DRIVER « [RES] [SendData] was sent: true 20:34:51.124 SERIAL « 0x010700135f00000fbb (9 bytes) 20:34:51.124 SERIAL » [ACK] (0x06) 20:34:51.125 DRIVER « [REQ] [SendData] callback id: 95 transmit status: OK 20:34:51.258 SERIAL « 0x010c000400130670060d02000a91 (14 bytes) 20:34:51.260 CNTRLR [Node 019] [+] [Configuration] 13: 10 20:34:51.261 SERIAL » [ACK] (0x06) 20:34:51.262 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 2 value: 10 20:34:51.264 SERIAL » 0x010a001312037005092560ce (12 bytes) 20:34:51.265 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 96 └─[ConfigurationCCGet] parameter #: 9 20:34:51.265 CNTRLR « [Node 019] parameter #13 has value: 10 20:34:51.265 CNTRLR » [Node 019] querying parameter #14 value... 20:34:51.269 SERIAL « [ACK] (0x06) 20:34:51.271 SERIAL « 0x0104011301e8 (6 bytes) 20:34:51.271 SERIAL » [ACK] (0x06) 20:34:51.272 DRIVER « [RES] [SendData] was sent: true 20:34:51.384 SERIAL « 0x010700136000000c87 (9 bytes) 20:34:51.385 SERIAL » [ACK] (0x06) 20:34:51.385 DRIVER « [REQ] [SendData] callback id: 96 transmit status: OK 20:34:51.395 SERIAL « 0x010b0004001205700609010099 (13 bytes) 20:34:51.396 CNTRLR [Node 018] [+] [Configuration] 9: 0 20:34:51.397 SERIAL » [ACK] (0x06) 20:34:51.398 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 1 value: 0 20:34:51.401 SERIAL » 0x010a001314037005022561c2 (12 bytes) 20:34:51.401 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 97 └─[ConfigurationCCGet] parameter #: 2 20:34:51.401 CNTRLR « [Node 018] parameter #9 has value: 0 20:34:51.402 CNTRLR [Node 018] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 20:34:51.407 SERIAL « [ACK] (0x06) 20:34:51.409 SERIAL « 0x0104011301e8 (6 bytes) 20:34:51.409 SERIAL » [ACK] (0x06) 20:34:51.411 DRIVER « [RES] [SendData] was sent: true 20:34:51.413 CNTRLR [Node 018] MeterCC: doing a complete interview... 20:34:51.413 CNTRLR » [Node 018] querying meter support... 20:34:51.448 SERIAL « 0x01070013610000048e (9 bytes) 20:34:51.448 SERIAL » [ACK] (0x06) 20:34:51.449 DRIVER « [REQ] [SendData] callback id: 97 transmit status: OK 20:34:51.458 SERIAL « 0x010c000400140670060202000695 (14 bytes) 20:34:51.460 CNTRLR [Node 020] [+] [Configuration] 2: 6 20:34:51.461 SERIAL » [ACK] (0x06) 20:34:51.461 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 2 value: 6 20:34:51.464 SERIAL » 0x010a001315034302012562f7 (12 bytes) 20:34:51.465 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 98 └─[ThermostatSetpointCCGet] setpoint type: Heating 20:34:51.465 CNTRLR « [Node 020] parameter #2 has value: 6 20:34:51.466 CNTRLR » [Node 020] querying parameter #3 value... 20:34:51.469 SERIAL « [ACK] (0x06) 20:34:51.471 SERIAL « 0x0104011301e8 (6 bytes) 20:34:51.471 SERIAL » [ACK] (0x06) 20:34:51.472 DRIVER « [RES] [SendData] was sent: true 20:34:52.872 SERIAL « 0x010700136200008d04 (9 bytes) 20:34:52.873 SERIAL » [ACK] (0x06) 20:34:52.873 DRIVER « [REQ] [SendData] callback id: 98 transmit status: OK 20:34:52.955 SERIAL « 0x010c00040015064303012200be39 (14 bytes) 20:34:52.956 CNTRLR [Node 021] [+] [Thermostat Setpoint] setpoint[1]: 19 [Endpoint 0] 20:34:52.957 CNTRLR [Node 021] [+] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 20:34:52.957 SERIAL » [ACK] (0x06) 20:34:52.959 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 20:34:52.960 SERIAL » 0x010a001316034302012563f5 (12 bytes) 20:34:52.960 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 99 └─[ThermostatSetpointCCGet] setpoint type: Heating 20:34:52.960 CNTRLR « [Node 021] received current value of setpoint Heating: 19 °C 20:34:52.960 CNTRLR » [Node 021] retrieving capabilities for setpoint Energy Save Heating... 20:34:52.962 SERIAL « [ACK] (0x06) 20:34:52.965 SERIAL « 0x0104011301e8 (6 bytes) 20:34:52.966 SERIAL » [ACK] (0x06) 20:34:52.966 DRIVER « [RES] [SendData] was sent: true 20:34:54.431 SERIAL « 0x01070013630000931b (9 bytes) 20:34:54.431 SERIAL » [ACK] (0x06) 20:34:54.432 DRIVER « [REQ] [SendData] callback id: 99 transmit status: OK 20:34:54.512 SERIAL « 0x010c00040016064303012200be3a (14 bytes) 20:34:54.513 CNTRLR [Node 022] [+] [Thermostat Setpoint] setpoint[1]: 19 [Endpoint 0] 20:34:54.514 CNTRLR [Node 022] [+] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 20:34:54.514 SERIAL » [ACK] (0x06) 20:34:54.515 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 20:34:54.518 SERIAL » 0x010a001317034302012564f3 (12 bytes) 20:34:54.518 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 100 └─[ThermostatSetpointCCGet] setpoint type: Heating 20:34:54.518 CNTRLR « [Node 022] received current value of setpoint Heating: 19 °C 20:34:54.518 CNTRLR » [Node 022] retrieving capabilities for setpoint Energy Save Heating... 20:34:54.519 SERIAL « [ACK] (0x06) 20:34:54.523 SERIAL « 0x0104011301e8 (6 bytes) 20:34:54.524 SERIAL » [ACK] (0x06) 20:34:54.524 DRIVER « [RES] [SendData] was sent: true 20:34:55.974 SERIAL « 0x01070013640000911e (9 bytes) 20:34:55.974 SERIAL » [ACK] (0x06) 20:34:55.975 DRIVER « [REQ] [SendData] callback id: 100 transmit status: OK 20:34:56.059 SERIAL « 0x010c00040017064303012200be3b (14 bytes) 20:34:56.060 CNTRLR [Node 023] [+] [Thermostat Setpoint] setpoint[1]: 19 [Endpoint 0] 20:34:56.061 CNTRLR [Node 023] [+] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 20:34:56.061 SERIAL » [ACK] (0x06) 20:34:56.062 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 20:34:56.069 SERIAL » 0x010a001318034302012565fd (12 bytes) 20:34:56.070 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 101 └─[ThermostatSetpointCCGet] setpoint type: Heating 20:34:56.070 CNTRLR « [Node 023] received current value of setpoint Heating: 19 °C 20:34:56.070 CNTRLR » [Node 023] retrieving capabilities for setpoint Energy Save Heating... 20:34:56.073 SERIAL « [ACK] (0x06) 20:34:56.075 SERIAL « 0x0104011301e8 (6 bytes) 20:34:56.075 SERIAL » [ACK] (0x06) 20:34:56.076 DRIVER « [RES] [SendData] was sent: true 20:34:57.531 SERIAL « 0x01070013650000921c (9 bytes) 20:34:57.531 SERIAL » [ACK] (0x06) 20:34:57.532 DRIVER « [REQ] [SendData] callback id: 101 transmit status: OK 20:34:57.616 SERIAL « 0x010c00040018064303012200be34 (14 bytes) 20:34:57.617 CNTRLR [Node 024] [+] [Thermostat Setpoint] setpoint[1]: 19 [Endpoint 0] 20:34:57.618 CNTRLR [Node 024] [+] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 20:34:57.618 SERIAL » [ACK] (0x06) 20:34:57.619 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 20:34:57.621 SERIAL » 0x010a00131a0370050d2566c4 (12 bytes) 20:34:57.621 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 102 └─[ConfigurationCCGet] parameter #: 13 20:34:57.621 CNTRLR « [Node 024] received current value of setpoint Heating: 19 °C 20:34:57.621 CNTRLR » [Node 024] retrieving capabilities for setpoint Energy Save Heating... 20:34:57.622 SERIAL « [ACK] (0x06) 20:34:57.627 SERIAL « 0x0104011301e8 (6 bytes) 20:34:57.627 SERIAL » [ACK] (0x06) 20:34:57.627 DRIVER « [RES] [SendData] was sent: true 20:34:57.730 SERIAL « 0x010700136600000b86 (9 bytes) 20:34:57.730 SERIAL » [ACK] (0x06) 20:34:57.731 DRIVER « [REQ] [SendData] callback id: 102 transmit status: OK 20:34:57.802 SERIAL « 0x010c0004001a0670060d02000a98 (14 bytes) 20:34:57.803 CNTRLR [Node 026] [+] [Configuration] 13: 10 20:34:57.804 SERIAL » [ACK] (0x06) 20:34:57.805 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 2 value: 10 20:34:57.808 SERIAL » 0x010a00131c0370050d2567c3 (12 bytes) 20:34:57.808 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 103 └─[ConfigurationCCGet] parameter #: 13 20:34:57.809 CNTRLR « [Node 026] parameter #13 has value: 10 20:34:57.809 CNTRLR » [Node 026] querying parameter #14 value... 20:34:57.812 SERIAL « [ACK] (0x06) 20:34:57.814 SERIAL « 0x0104011301e8 (6 bytes) 20:34:57.815 SERIAL » [ACK] (0x06) 20:34:57.815 DRIVER « [RES] [SendData] was sent: true 20:34:57.884 SERIAL « 0x01070013670000078b (9 bytes) 20:34:57.884 SERIAL » [ACK] (0x06) 20:34:57.885 DRIVER « [REQ] [SendData] callback id: 103 transmit status: OK 20:34:57.894 SERIAL « 0x010c0004001c0670060d02000a9e (14 bytes) 20:34:57.896 CNTRLR [Node 028] [+] [Configuration] 13: 10 20:34:57.897 SERIAL » [ACK] (0x06) 20:34:57.898 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 2 value: 10 20:34:57.900 SERIAL » 0x010a001303037005142568ca (12 bytes) 20:34:57.901 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 104 └─[ConfigurationCCGet] parameter #: 20 20:34:57.901 CNTRLR « [Node 028] parameter #13 has value: 10 20:34:57.901 CNTRLR » [Node 028] querying parameter #14 value... 20:34:57.905 SERIAL « [ACK] (0x06) 20:34:57.906 SERIAL « 0x0104011301e8 (6 bytes) 20:34:57.907 SERIAL » [ACK] (0x06) 20:34:57.908 DRIVER « [RES] [SendData] was sent: true 20:34:57.931 SERIAL « 0x010700136800000281 (9 bytes) 20:34:57.931 SERIAL » [ACK] (0x06) 20:34:57.932 DRIVER « [REQ] [SendData] callback id: 104 transmit status: OK 20:34:57.938 SERIAL « 0x010b0004000305700614010095 (13 bytes) 20:34:57.941 CNTRLR [Node 003] [+] [Configuration] 20: 0 20:34:57.942 SERIAL » [ACK] (0x06) 20:34:57.943 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 0 20:34:57.946 SERIAL » 0x010a001305033201482569d7 (12 bytes) 20:34:57.947 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 105 └─[MeterCCGet] rate type: Consumed duration: kVAh 20:34:57.947 CNTRLR « [Node 003] parameter #20 has value: 0 20:34:57.947 CNTRLR » [Node 003] querying parameter #21 value... 20:34:57.951 SERIAL « [ACK] (0x06) 20:34:57.953 SERIAL « 0x0104011301e8 (6 bytes) 20:34:57.953 SERIAL » [ACK] (0x06) 20:34:57.954 DRIVER « [RES] [SendData] was sent: true 20:34:57.967 SERIAL « 0x010700136900000280 (9 bytes) 20:34:57.967 SERIAL » [ACK] (0x06) 20:34:57.968 DRIVER « [REQ] [SendData] callback id: 105 transmit status: OK 20:34:57.978 SERIAL « 0x0114000400050e3202214c00001f9d015900001f9de1 (22 bytes) 20:34:57.979 CNTRLR [Node 005] [Meter] value[65793]: metadata updated [Endpoint 0] 20:34:57.980 CNTRLR [Node 005] [Meter] previousValue[65793]: metadata updated [Endpoint 0] 20:34:57.981 CNTRLR [Node 005] [Meter] deltaTime[65793]: metadata updated [Endpoint 0] 20:34:57.981 CNTRLR [Node 005] [+] [Meter] value[65793]: 80.93 [Endpoint 0] 20:34:57.982 CNTRLR [Node 005] [+] [Meter] previousValue[65793]: 80.93 [Endpoint 0] 20:34:57.982 CNTRLR [Node 005] [+] [Meter] deltaTime[65793]: 345 [Endpoint 0] 20:34:57.983 SERIAL » [ACK] (0x06) 20:34:57.984 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kVAh rate type: Consumed value: 80.93 time delta: 345 seconds prev. value: 80.93 20:34:57.987 SERIAL » 0x010a00130603320148256ad7 (12 bytes) 20:34:57.987 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 106 └─[MeterCCGet] rate type: Consumed duration: kVAh 20:34:57.988 CNTRLR » [Node 005] querying meter value (type = Electric, scale = W, rate type = Consu med)... 20:34:57.993 SERIAL « [ACK] (0x06) 20:34:57.994 SERIAL « 0x0104011301e8 (6 bytes) 20:34:57.994 SERIAL » [ACK] (0x06) 20:34:57.995 DRIVER « [RES] [SendData] was sent: true 20:34:58.008 SERIAL « 0x010700136a00000283 (9 bytes) 20:34:58.008 SERIAL » [ACK] (0x06) 20:34:58.008 DRIVER « [REQ] [SendData] callback id: 106 transmit status: OK 20:34:58.019 SERIAL « 0x0114000400060e3202214c00000482015800000482e3 (22 bytes) 20:34:58.019 CNTRLR [Node 006] [Meter] value[65793]: metadata updated [Endpoint 0] 20:34:58.020 CNTRLR [Node 006] [Meter] previousValue[65793]: metadata updated [Endpoint 0] 20:34:58.020 CNTRLR [Node 006] [Meter] deltaTime[65793]: metadata updated [Endpoint 0] 20:34:58.020 CNTRLR [Node 006] [+] [Meter] value[65793]: 11.54 [Endpoint 0] 20:34:58.021 CNTRLR [Node 006] [+] [Meter] previousValue[65793]: 11.54 [Endpoint 0] 20:34:58.022 CNTRLR [Node 006] [+] [Meter] deltaTime[65793]: 344 [Endpoint 0] 20:34:58.022 SERIAL » [ACK] (0x06) 20:34:58.023 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kVAh rate type: Consumed value: 11.54 time delta: 344 seconds prev. value: 11.54 20:34:58.028 SERIAL » 0x010a00130203700506256bda (12 bytes) 20:34:58.028 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 107 └─[ConfigurationCCGet] parameter #: 6 20:34:58.028 CNTRLR » [Node 006] querying meter value (type = Electric, scale = W, rate type = Consu med)... 20:34:58.044 SERIAL « [ACK] (0x06) 20:34:58.046 SERIAL « 0x0104011301e8 (6 bytes) 20:34:58.046 SERIAL » [ACK] (0x06) 20:34:58.047 DRIVER « [RES] [SendData] was sent: true 20:34:58.053 SERIAL « 0x010700136b00000282 (9 bytes) 20:34:58.053 SERIAL » [ACK] (0x06) 20:34:58.055 DRIVER « [REQ] [SendData] callback id: 107 transmit status: OK 20:34:58.077 SERIAL « 0x010b0004000205700606010187 (13 bytes) 20:34:58.078 CNTRLR [Node 002] [+] [Configuration] 6: 1 20:34:58.079 SERIAL » [ACK] (0x06) 20:34:58.079 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 1 value: 1 20:34:58.080 SERIAL » 0x010a0013130370050e256cc4 (12 bytes) 20:34:58.080 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 108 └─[ConfigurationCCGet] parameter #: 14 20:34:58.080 CNTRLR « [Node 002] parameter #6 has value: 1 20:34:58.081 CNTRLR » [Node 002] querying parameter #7 value... 20:34:58.082 SERIAL « [ACK] (0x06) 20:34:58.086 SERIAL « 0x0104011301e8 (6 bytes) 20:34:58.086 SERIAL » [ACK] (0x06) 20:34:58.086 DRIVER « [RES] [SendData] was sent: true 20:34:58.227 SERIAL « 0x010700136c00000e89 (9 bytes) 20:34:58.227 SERIAL » [ACK] (0x06) 20:34:58.228 DRIVER « [REQ] [SendData] callback id: 108 transmit status: OK 20:34:58.358 SERIAL « 0x010c000400130670060e020e1086 (14 bytes) 20:34:58.360 CNTRLR [Node 019] [+] [Configuration] 14: 3600 20:34:58.360 SERIAL » [ACK] (0x06) 20:34:58.361 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 2 value: 3600 20:34:58.364 SERIAL » 0x0109001312023203256d8c (11 bytes) 20:34:58.364 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 109 └─[MeterCCSupportedGet] 20:34:58.365 CNTRLR « [Node 019] parameter #14 has value: 3600 20:34:58.365 CNTRLR » [Node 019] querying parameter #15 value... 20:34:58.368 SERIAL « [ACK] (0x06) 20:34:58.370 SERIAL « 0x0104011301e8 (6 bytes) 20:34:58.371 SERIAL » [ACK] (0x06) 20:34:58.372 DRIVER « [RES] [SendData] was sent: true 20:34:58.725 SERIAL « 0x010700136d000024a2 (9 bytes) 20:34:58.726 SERIAL » [ACK] (0x06) 20:34:58.726 DRIVER « [REQ] [SendData] callback id: 109 transmit status: OK 20:34:58.736 SERIAL « 0x010c00040012063204a1ff010389 (14 bytes) 20:34:58.737 CNTRLR [Node 018] [+] [Meter] type: 1 [Endpoint 0] [internal] 20:34:58.737 CNTRLR [Node 018] [+] [Meter] supportsReset: true [Endpoint 0] [internal] 20:34:58.737 CNTRLR [Node 018] [+] [Meter] supportedScales: 0,1,2,3,4,5,6, [Endpoint 0] [internal] 7,8 20:34:58.738 CNTRLR [Node 018] [+] [Meter] supportedRateTypes: 1 [Endpoint 0] [internal] 20:34:58.738 CNTRLR [Node 018] [Meter] reset: metadata updated [Endpoint 0] 20:34:58.739 SERIAL » [ACK] (0x06) 20:34:58.739 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MeterCCSupportedReport] type: Electric supports reset: true supported scales: · kWh · kVAh · W · Pulse count · V · A · Power Factor · kVar · kVarh supported rate types: Consumed 20:34:58.741 SERIAL » 0x010a00131403700503256ecc (12 bytes) 20:34:58.741 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 110 └─[ConfigurationCCGet] parameter #: 3 20:34:58.741 CNTRLR « [Node 018] received meter support: type: Electric supported scales: · kWh · kVAh · W · Pulse count · V · A · Power Factor · kVar · kVarh supported rate types: · Consumed supports reset: true 20:34:58.741 CNTRLR » [Node 018] querying meter value (type = Electric, scale = kWh, rate type = Con sumed)... 20:34:58.743 SERIAL « [ACK] (0x06) 20:34:58.746 SERIAL « 0x0104011301e8 (6 bytes) 20:34:58.747 SERIAL » [ACK] (0x06) 20:34:58.747 DRIVER « [RES] [SendData] was sent: true 20:34:58.766 SERIAL « 0x010700136e00000287 (9 bytes) 20:34:58.766 SERIAL » [ACK] (0x06) 20:34:58.767 DRIVER « [REQ] [SendData] callback id: 110 transmit status: OK 20:34:58.791 SERIAL « 0x010c000400140670060302051483 (14 bytes) 20:34:58.793 CNTRLR [Node 020] [+] [Configuration] 3: 1300 20:34:58.794 SERIAL » [ACK] (0x06) 20:34:58.794 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 2 value: 1300 20:34:58.797 SERIAL » 0x010a0013150343090b256ffb (12 bytes) 20:34:58.798 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 111 └─[ThermostatSetpointCCCapabilitiesGet] setpoint type: Energy Save Heating 20:34:58.798 CNTRLR « [Node 020] parameter #3 has value: 1300 20:34:58.798 CNTRLR » [Node 020] querying parameter #4 value... 20:34:58.802 SERIAL « [ACK] (0x06) 20:34:58.804 SERIAL « 0x0104011301e8 (6 bytes) 20:34:58.804 SERIAL » [ACK] (0x06) 20:34:58.805 DRIVER « [RES] [SendData] was sent: true 20:35:00.188 SERIAL « 0x010700136f00008a0e (9 bytes) 20:35:00.188 SERIAL » [ACK] (0x06) 20:35:00.189 DRIVER « [REQ] [SendData] callback id: 111 transmit status: OK 20:35:00.272 SERIAL « 0x010f0004001509430a0b220050220118e3 (17 bytes) 20:35:00.274 CNTRLR [Node 021] [Thermostat Setpoint] setpoint[11]: metadata updated [Endpoint 0] 20:35:00.274 SERIAL » [ACK] (0x06) 20:35:00.275 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCCapabilitiesReport] setpoint type: Energy Save Heating min value: 8 °C max value: 28 °C 20:35:00.278 SERIAL » 0x010a0013160343090b2570e7 (12 bytes) 20:35:00.278 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 112 └─[ThermostatSetpointCCCapabilitiesGet] setpoint type: Energy Save Heating 20:35:00.279 CNTRLR « [Node 021] received capabilities for setpoint Energy Save Heating: minimum value: 8 °C maximum value: 28 °C 20:35:00.279 CNTRLR » [Node 021] querying current value of setpoint Energy Save Heating... 20:35:00.282 SERIAL « [ACK] (0x06) 20:35:00.284 SERIAL « 0x0104011301e8 (6 bytes) 20:35:00.284 SERIAL » [ACK] (0x06) 20:35:00.284 DRIVER « [RES] [SendData] was sent: true 20:35:06.481 SERIAL « 0x010700137000026cf5 (9 bytes) 20:35:06.482 SERIAL » [ACK] (0x06) 20:35:06.482 DRIVER « [REQ] [SendData] callback id: 112 transmit status: OK 20:35:06.567 SERIAL « 0x010f0004001609430a0b220050220118e0 (17 bytes) 20:35:06.568 CNTRLR [Node 022] [Thermostat Setpoint] setpoint[11]: metadata updated [Endpoint 0] 20:35:06.569 SERIAL » [ACK] (0x06) 20:35:06.569 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCCapabilitiesReport] setpoint type: Energy Save Heating min value: 8 °C max value: 28 °C 20:35:06.572 SERIAL » 0x010a0013170343090b2571e7 (12 bytes) 20:35:06.572 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 113 └─[ThermostatSetpointCCCapabilitiesGet] setpoint type: Energy Save Heating 20:35:06.572 CNTRLR « [Node 022] received capabilities for setpoint Energy Save Heating: minimum value: 8 °C maximum value: 28 °C 20:35:06.572 CNTRLR » [Node 022] querying current value of setpoint Energy Save Heating... 20:35:06.574 SERIAL « [ACK] (0x06) 20:35:06.578 SERIAL « 0x0104011301e8 (6 bytes) 20:35:06.578 SERIAL » [ACK] (0x06) 20:35:06.579 DRIVER « [RES] [SendData] was sent: true 20:35:08.006 SERIAL « 0x010700137100008f15 (9 bytes) 20:35:08.007 SERIAL » [ACK] (0x06) 20:35:08.007 DRIVER « [REQ] [SendData] callback id: 113 transmit status: OK 20:35:08.087 SERIAL « 0x010f0004001709430a0b220050220118e1 (17 bytes) 20:35:08.088 CNTRLR [Node 023] [Thermostat Setpoint] setpoint[11]: metadata updated [Endpoint 0] 20:35:08.088 SERIAL » [ACK] (0x06) 20:35:08.089 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCCapabilitiesReport] setpoint type: Energy Save Heating min value: 8 °C max value: 28 °C 20:35:08.092 SERIAL » 0x010a0013180343090b2572eb (12 bytes) 20:35:08.092 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 114 └─[ThermostatSetpointCCCapabilitiesGet] setpoint type: Energy Save Heating 20:35:08.093 CNTRLR « [Node 023] received capabilities for setpoint Energy Save Heating: minimum value: 8 °C maximum value: 28 °C 20:35:08.093 CNTRLR » [Node 023] querying current value of setpoint Energy Save Heating... 20:35:08.094 SERIAL « [ACK] (0x06) 20:35:08.097 SERIAL « 0x0104011301e8 (6 bytes) 20:35:08.097 SERIAL » [ACK] (0x06) 20:35:08.098 DRIVER « [RES] [SendData] was sent: true 20:35:09.526 SERIAL « 0x010700137200008f16 (9 bytes) 20:35:09.526 SERIAL » [ACK] (0x06) 20:35:09.527 DRIVER « [REQ] [SendData] callback id: 114 transmit status: OK 20:35:09.604 SERIAL « 0x010f0004001809430a0b220050220118ee (17 bytes) 20:35:09.605 CNTRLR [Node 024] [Thermostat Setpoint] setpoint[11]: metadata updated [Endpoint 0] 20:35:09.606 SERIAL » [ACK] (0x06) 20:35:09.607 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCCapabilitiesReport] setpoint type: Energy Save Heating min value: 8 °C max value: 28 °C 20:35:09.609 SERIAL » 0x010a00131a0370050e2573d2 (12 bytes) 20:35:09.610 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 115 └─[ConfigurationCCGet] parameter #: 14 20:35:09.610 CNTRLR « [Node 024] received capabilities for setpoint Energy Save Heating: minimum value: 8 °C maximum value: 28 °C 20:35:09.610 CNTRLR » [Node 024] querying current value of setpoint Energy Save Heating... 20:35:09.611 SERIAL « [ACK] (0x06) 20:35:09.615 SERIAL « 0x0104011301e8 (6 bytes) 20:35:09.616 SERIAL » [ACK] (0x06) 20:35:09.616 DRIVER « [RES] [SendData] was sent: true 20:35:09.720 SERIAL « 0x010700137300000b93 (9 bytes) 20:35:09.720 SERIAL » [ACK] (0x06) 20:35:09.721 DRIVER « [REQ] [SendData] callback id: 115 transmit status: OK 20:35:09.791 SERIAL « 0x010c0004001a0670060e020e108f (14 bytes) 20:35:09.793 CNTRLR [Node 026] [+] [Configuration] 14: 3600 20:35:09.794 SERIAL » [ACK] (0x06) 20:35:09.795 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 2 value: 3600 20:35:09.798 SERIAL » 0x010a00131c0370050e2574d3 (12 bytes) 20:35:09.798 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 116 └─[ConfigurationCCGet] parameter #: 14 20:35:09.799 CNTRLR « [Node 026] parameter #14 has value: 3600 20:35:09.799 CNTRLR » [Node 026] querying parameter #15 value... 20:35:09.805 SERIAL « [ACK] (0x06) 20:35:09.806 SERIAL « 0x0104011301e8 (6 bytes) 20:35:09.807 SERIAL » [ACK] (0x06) 20:35:09.807 DRIVER « [RES] [SendData] was sent: true 20:35:09.875 SERIAL « 0x010700137400000798 (9 bytes) 20:35:09.875 SERIAL » [ACK] (0x06) 20:35:09.876 DRIVER « [REQ] [SendData] callback id: 116 transmit status: OK 20:35:09.885 SERIAL « 0x010c0004001c0670060e020e1089 (14 bytes) 20:35:09.886 CNTRLR [Node 028] [+] [Configuration] 14: 3600 20:35:09.887 SERIAL » [ACK] (0x06) 20:35:09.888 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 2 value: 3600 20:35:09.893 SERIAL » 0x010a001303037005152575d6 (12 bytes) 20:35:09.893 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 117 └─[ConfigurationCCGet] parameter #: 21 20:35:09.894 CNTRLR « [Node 028] parameter #14 has value: 3600 20:35:09.894 CNTRLR » [Node 028] querying parameter #15 value... 20:35:09.898 SERIAL « [ACK] (0x06) 20:35:09.899 SERIAL « 0x0104011301e8 (6 bytes) 20:35:09.900 SERIAL » [ACK] (0x06) 20:35:09.901 DRIVER « [RES] [SendData] was sent: true 20:35:09.919 SERIAL « 0x01070013750000029c (9 bytes) 20:35:09.919 SERIAL » [ACK] (0x06) 20:35:09.920 DRIVER « [REQ] [SendData] callback id: 117 transmit status: OK 20:35:09.931 SERIAL « 0x010c000400030670061502012cbe (14 bytes) 20:35:09.933 CNTRLR [Node 003] [+] [Configuration] 21: 300 20:35:09.934 SERIAL » [ACK] (0x06) 20:35:09.935 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 21 value size: 2 value: 300 20:35:09.938 SERIAL » 0x010a001305033201502576d0 (12 bytes) 20:35:09.939 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 118 └─[MeterCCGet] rate type: Consumed duration: W 20:35:09.939 CNTRLR « [Node 003] parameter #21 has value: 300 20:35:09.939 CNTRLR » [Node 003] querying parameter #22 value... 20:35:09.943 SERIAL « [ACK] (0x06) 20:35:09.945 SERIAL « 0x0104011301e8 (6 bytes) 20:35:09.945 SERIAL » [ACK] (0x06) 20:35:09.947 DRIVER « [RES] [SendData] was sent: true 20:35:09.959 SERIAL « 0x01070013760000019c (9 bytes) 20:35:09.959 SERIAL » [ACK] (0x06) 20:35:09.960 DRIVER « [REQ] [SendData] callback id: 118 transmit status: OK 20:35:09.970 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:35:09.970 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:35:09.971 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:35:09.971 SERIAL » [ACK] (0x06) 20:35:09.972 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:35:09.974 SERIAL » 0x010a001306033201502577d2 (12 bytes) 20:35:09.974 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 119 └─[MeterCCGet] rate type: Consumed duration: W 20:35:09.975 CNTRLR » [Node 005] querying meter value (type = Electric, scale = Pulse count, rate ty pe = Consumed)... 20:35:09.977 SERIAL « [ACK] (0x06) 20:35:09.980 SERIAL « 0x0104011301e8 (6 bytes) 20:35:09.980 SERIAL » [ACK] (0x06) 20:35:09.980 DRIVER « [RES] [SendData] was sent: true 20:35:09.995 SERIAL « 0x01070013770000029e (9 bytes) 20:35:09.995 SERIAL » [ACK] (0x06) 20:35:09.995 DRIVER « [REQ] [SendData] callback id: 119 transmit status: OK 20:35:10.005 SERIAL « 0x0110000400060a32022134000000000000c2 (18 bytes) 20:35:10.006 CNTRLR [Node 006] [Meter] previousValue[66049]: metadata updated [Endpoint 0] 20:35:10.007 CNTRLR [Node 006] [Meter] deltaTime[66049]: metadata updated [Endpoint 0] 20:35:10.007 CNTRLR [Node 006] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:35:10.008 CNTRLR [Node 006] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:35:10.008 SERIAL » [ACK] (0x06) 20:35:10.009 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:35:10.013 SERIAL » 0x010a001302037005072578c8 (12 bytes) 20:35:10.013 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 120 └─[ConfigurationCCGet] parameter #: 7 20:35:10.013 CNTRLR » [Node 006] querying meter value (type = Electric, scale = Pulse count, rate ty pe = Consumed)... 20:35:10.016 SERIAL « [ACK] (0x06) 20:35:10.018 SERIAL « 0x0104011301e8 (6 bytes) 20:35:10.019 SERIAL » [ACK] (0x06) 20:35:10.020 DRIVER « [RES] [SendData] was sent: true 20:35:10.038 SERIAL « 0x010700137800000291 (9 bytes) 20:35:10.038 SERIAL » [ACK] (0x06) 20:35:10.039 DRIVER « [REQ] [SendData] callback id: 120 transmit status: OK 20:35:10.063 SERIAL « 0x010b0004000205700607010186 (13 bytes) 20:35:10.065 CNTRLR [Node 002] [+] [Configuration] 7: 1 20:35:10.066 SERIAL » [ACK] (0x06) 20:35:10.066 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 7 value size: 1 value: 1 20:35:10.069 SERIAL » 0x010a0013130370050f2579d0 (12 bytes) 20:35:10.069 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 121 └─[ConfigurationCCGet] parameter #: 15 20:35:10.070 CNTRLR « [Node 002] parameter #7 has value: 1 20:35:10.070 CNTRLR » [Node 002] querying parameter #8 value... 20:35:10.073 SERIAL « [ACK] (0x06) 20:35:10.075 SERIAL « 0x0104011301e8 (6 bytes) 20:35:10.075 SERIAL » [ACK] (0x06) 20:35:10.076 DRIVER « [RES] [SendData] was sent: true 20:35:10.216 SERIAL « 0x010700137900000e9c (9 bytes) 20:35:10.217 SERIAL » [ACK] (0x06) 20:35:10.218 DRIVER « [REQ] [SendData] callback id: 121 transmit status: OK 20:35:10.346 SERIAL « 0x010b000400130570060f01009e (13 bytes) 20:35:10.348 CNTRLR [Node 019] [+] [Configuration] 15: 0 20:35:10.349 SERIAL » [ACK] (0x06) 20:35:10.350 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 15 value size: 1 value: 0 20:35:10.352 SERIAL » 0x010a00131203320140257adb (12 bytes) 20:35:10.353 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 122 └─[MeterCCGet] rate type: Consumed duration: kWh 20:35:10.353 CNTRLR « [Node 019] parameter #15 has value: 0 20:35:10.353 CNTRLR » [Node 019] querying parameter #20 value... 20:35:10.359 SERIAL « [ACK] (0x06) 20:35:10.360 SERIAL « 0x0104011301e8 (6 bytes) 20:35:10.360 SERIAL » [ACK] (0x06) 20:35:10.361 DRIVER « [RES] [SendData] was sent: true 20:35:10.475 SERIAL « 0x010700137a00000c9d (9 bytes) 20:35:10.475 SERIAL » [ACK] (0x06) 20:35:10.476 DRIVER « [REQ] [SendData] callback id: 122 transmit status: OK 20:35:10.486 SERIAL « 0x0114000400120e32022144000002b30890000002b33e (22 bytes) 20:35:10.487 CNTRLR [Node 018] [Meter] value[65537]: metadata updated [Endpoint 0] 20:35:10.487 CNTRLR [Node 018] [Meter] previousValue[65537]: metadata updated [Endpoint 0] 20:35:10.488 CNTRLR [Node 018] [Meter] deltaTime[65537]: metadata updated [Endpoint 0] 20:35:10.488 CNTRLR [Node 018] [+] [Meter] value[65537]: 6.91 [Endpoint 0] 20:35:10.489 CNTRLR [Node 018] [+] [Meter] previousValue[65537]: 6.91 [Endpoint 0] 20:35:10.489 CNTRLR [Node 018] [+] [Meter] deltaTime[65537]: 2192 [Endpoint 0] 20:35:10.490 SERIAL » [ACK] (0x06) 20:35:10.492 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 6.91 time delta: 2192 seconds prev. value: 6.91 20:35:10.497 SERIAL » 0x010a00131403700504257bde (12 bytes) 20:35:10.497 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 123 └─[ConfigurationCCGet] parameter #: 4 20:35:10.497 CNTRLR » [Node 018] querying meter value (type = Electric, scale = kVAh, rate type = Co nsumed)... 20:35:10.502 SERIAL « [ACK] (0x06) 20:35:10.504 SERIAL « 0x0104011301e8 (6 bytes) 20:35:10.504 SERIAL » [ACK] (0x06) 20:35:10.506 DRIVER « [RES] [SendData] was sent: true 20:35:10.522 SERIAL « 0x010700137b00000393 (9 bytes) 20:35:10.523 SERIAL » [ACK] (0x06) 20:35:10.523 DRIVER « [REQ] [SendData] callback id: 123 transmit status: OK 20:35:10.548 SERIAL « 0x010c0004001406700604022710a2 (14 bytes) 20:35:10.549 CNTRLR [Node 020] [+] [Configuration] 4: 10000 20:35:10.550 SERIAL » [ACK] (0x06) 20:35:10.551 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 2 value: 10000 20:35:10.554 SERIAL » 0x010a0013150343020b257ce3 (12 bytes) 20:35:10.554 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 124 └─[ThermostatSetpointCCGet] setpoint type: Energy Save Heating 20:35:10.555 CNTRLR « [Node 020] parameter #4 has value: 10000 20:35:10.555 CNTRLR » [Node 020] querying parameter #5 value... 20:35:10.559 SERIAL « [ACK] (0x06) 20:35:10.561 SERIAL « 0x0104011301e8 (6 bytes) 20:35:10.561 SERIAL » [ACK] (0x06) 20:35:10.563 DRIVER « [RES] [SendData] was sent: true 20:35:11.944 SERIAL « 0x010700137c00008b1c (9 bytes) 20:35:11.944 SERIAL » [ACK] (0x06) 20:35:11.945 DRIVER « [REQ] [SendData] callback id: 124 transmit status: OK 20:35:12.029 SERIAL « 0x010c000400150643030b2200b439 (14 bytes) 20:35:12.030 CNTRLR [Node 021] [+] [Thermostat Setpoint] setpoint[11]: 18 [Endpoint 0] 20:35:12.031 CNTRLR [Node 021] [+] [Thermostat Setpoint] setpointScale[11] [Endpoint 0] [internal] : 0 20:35:12.031 SERIAL » [ACK] (0x06) 20:35:12.032 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Energy Save Heating value: 18 °C 20:35:12.035 SERIAL » 0x010a0013160343020b257de1 (12 bytes) 20:35:12.035 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 125 └─[ThermostatSetpointCCGet] setpoint type: Energy Save Heating 20:35:12.036 CNTRLR « [Node 021] received current value of setpoint Energy Save Heating: 18 °C 20:35:12.036 CNTRLR [Node 021] [+] [Thermostat Setpoint] interviewComplete [Endpoint 0] [internal] : true 20:35:12.042 SERIAL « [ACK] (0x06) 20:35:12.045 SERIAL « 0x0104011301e8 (6 bytes) 20:35:12.045 SERIAL » [ACK] (0x06) 20:35:12.045 DRIVER « [RES] [SendData] was sent: true 20:35:12.048 CNTRLR [Node 021] ProtectionCC: doing a complete interview... 20:35:12.048 CNTRLR » [Node 021] querying protection status... 20:35:13.672 SERIAL « 0x010700137d0000a432 (9 bytes) 20:35:13.673 SERIAL » [ACK] (0x06) 20:35:13.673 DRIVER « [REQ] [SendData] callback id: 125 transmit status: OK 20:35:13.757 SERIAL « 0x010c000400160643030b2200b43a (14 bytes) 20:35:13.758 CNTRLR [Node 022] [+] [Thermostat Setpoint] setpoint[11]: 18 [Endpoint 0] 20:35:13.759 CNTRLR [Node 022] [+] [Thermostat Setpoint] setpointScale[11] [Endpoint 0] [internal] : 0 20:35:13.759 SERIAL » [ACK] (0x06) 20:35:13.760 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Energy Save Heating value: 18 °C 20:35:13.765 SERIAL » 0x010a0013170343020b257ee3 (12 bytes) 20:35:13.765 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 126 └─[ThermostatSetpointCCGet] setpoint type: Energy Save Heating 20:35:13.765 CNTRLR « [Node 022] received current value of setpoint Energy Save Heating: 18 °C 20:35:13.765 CNTRLR [Node 022] [+] [Thermostat Setpoint] interviewComplete [Endpoint 0] [internal] : true 20:35:13.769 SERIAL « [ACK] (0x06) 20:35:13.770 SERIAL « 0x0104011301e8 (6 bytes) 20:35:13.770 SERIAL » [ACK] (0x06) 20:35:13.770 CNTRLR [Node 022] ProtectionCC: doing a complete interview... 20:35:13.770 CNTRLR » [Node 022] querying protection status... 20:35:13.771 DRIVER « [RES] [SendData] was sent: true 20:35:15.329 SERIAL « 0x010700137e00009c09 (9 bytes) 20:35:15.329 SERIAL » [ACK] (0x06) 20:35:15.330 DRIVER « [REQ] [SendData] callback id: 126 transmit status: OK 20:35:15.411 SERIAL « 0x010c000400170643030b2200b43b (14 bytes) 20:35:15.412 CNTRLR [Node 023] [+] [Thermostat Setpoint] setpoint[11]: 18 [Endpoint 0] 20:35:15.413 CNTRLR [Node 023] [+] [Thermostat Setpoint] setpointScale[11] [Endpoint 0] [internal] : 0 20:35:15.413 SERIAL » [ACK] (0x06) 20:35:15.413 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Energy Save Heating value: 18 °C 20:35:15.415 SERIAL » 0x010a0013180343020b257fed (12 bytes) 20:35:15.416 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 127 └─[ThermostatSetpointCCGet] setpoint type: Energy Save Heating 20:35:15.416 CNTRLR « [Node 023] received current value of setpoint Energy Save Heating: 18 °C 20:35:15.416 CNTRLR [Node 023] [+] [Thermostat Setpoint] interviewComplete [Endpoint 0] [internal] : true 20:35:15.420 SERIAL « [ACK] (0x06) 20:35:15.422 SERIAL « 0x0104011301e8 (6 bytes) 20:35:15.422 SERIAL » [ACK] (0x06) 20:35:15.423 DRIVER « [RES] [SendData] was sent: true 20:35:15.424 CNTRLR [Node 023] ProtectionCC: doing a complete interview... 20:35:15.424 CNTRLR » [Node 023] querying protection status... 20:35:16.881 SERIAL « 0x010700137f00009307 (9 bytes) 20:35:16.881 SERIAL » [ACK] (0x06) 20:35:16.882 DRIVER « [REQ] [SendData] callback id: 127 transmit status: OK 20:35:16.964 SERIAL « 0x010c000400180643030b2200b434 (14 bytes) 20:35:16.965 CNTRLR [Node 024] [+] [Thermostat Setpoint] setpoint[11]: 18 [Endpoint 0] 20:35:16.966 CNTRLR [Node 024] [+] [Thermostat Setpoint] setpointScale[11] [Endpoint 0] [internal] : 0 20:35:16.966 SERIAL » [ACK] (0x06) 20:35:16.968 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Energy Save Heating value: 18 °C 20:35:16.971 SERIAL » 0x010a00131a0370050f258020 (12 bytes) 20:35:16.971 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 128 └─[ConfigurationCCGet] parameter #: 15 20:35:16.971 CNTRLR « [Node 024] received current value of setpoint Energy Save Heating: 18 °C 20:35:16.972 CNTRLR [Node 024] [+] [Thermostat Setpoint] interviewComplete [Endpoint 0] [internal] : true 20:35:16.978 SERIAL « [ACK] (0x06) 20:35:16.982 SERIAL « 0x0104011301e8 (6 bytes) 20:35:16.983 SERIAL » [ACK] (0x06) 20:35:16.983 DRIVER « [RES] [SendData] was sent: true 20:35:16.985 CNTRLR [Node 024] ProtectionCC: doing a complete interview... 20:35:16.985 CNTRLR » [Node 024] querying protection status... 20:35:17.080 SERIAL « 0x010700138000000a61 (9 bytes) 20:35:17.080 SERIAL » [ACK] (0x06) 20:35:17.081 DRIVER « [REQ] [SendData] callback id: 128 transmit status: OK 20:35:17.151 SERIAL « 0x010b0004001a0570060f010097 (13 bytes) 20:35:17.153 CNTRLR [Node 026] [+] [Configuration] 15: 0 20:35:17.154 SERIAL » [ACK] (0x06) 20:35:17.154 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 15 value size: 1 value: 0 20:35:17.157 SERIAL » 0x010a00131c0370050f258127 (12 bytes) 20:35:17.157 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 129 └─[ConfigurationCCGet] parameter #: 15 20:35:17.158 CNTRLR « [Node 026] parameter #15 has value: 0 20:35:17.158 CNTRLR » [Node 026] querying parameter #20 value... 20:35:17.161 SERIAL « [ACK] (0x06) 20:35:17.164 SERIAL « 0x0104011301e8 (6 bytes) 20:35:17.164 SERIAL » [ACK] (0x06) 20:35:17.165 DRIVER « [RES] [SendData] was sent: true 20:35:17.235 SERIAL « 0x010700138100000862 (9 bytes) 20:35:17.235 SERIAL » [ACK] (0x06) 20:35:17.236 DRIVER « [REQ] [SendData] callback id: 129 transmit status: OK 20:35:17.244 SERIAL « 0x010b0004001c0570060f010091 (13 bytes) 20:35:17.246 CNTRLR [Node 028] [+] [Configuration] 15: 0 20:35:17.247 SERIAL » [ACK] (0x06) 20:35:17.248 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 15 value size: 1 value: 0 20:35:17.251 SERIAL » 0x010a00130303700516258222 (12 bytes) 20:35:17.252 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 130 └─[ConfigurationCCGet] parameter #: 22 20:35:17.252 CNTRLR « [Node 028] parameter #15 has value: 0 20:35:17.252 CNTRLR » [Node 028] querying parameter #20 value... 20:35:17.257 SERIAL « [ACK] (0x06) 20:35:17.260 SERIAL « 0x0104011301e8 (6 bytes) 20:35:17.260 SERIAL » [ACK] (0x06) 20:35:17.261 DRIVER « [RES] [SendData] was sent: true 20:35:17.277 SERIAL « 0x01070013820000026b (9 bytes) 20:35:17.277 SERIAL » [ACK] (0x06) 20:35:17.278 DRIVER « [REQ] [SendData] callback id: 130 transmit status: OK 20:35:17.289 SERIAL « 0x010c00040003067006160201f465 (14 bytes) 20:35:17.291 CNTRLR [Node 003] [+] [Configuration] 22: 500 20:35:17.292 SERIAL » [ACK] (0x06) 20:35:17.293 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 500 20:35:17.298 SERIAL » 0x010a0013050332015825832d (12 bytes) 20:35:17.298 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 131 └─[MeterCCGet] rate type: Consumed duration: Pulse count 20:35:17.299 CNTRLR « [Node 003] parameter #22 has value: 500 20:35:17.299 CNTRLR » [Node 003] querying parameter #23 value... 20:35:17.303 SERIAL « [ACK] (0x06) 20:35:17.304 SERIAL « 0x0104011301e8 (6 bytes) 20:35:17.304 SERIAL » [ACK] (0x06) 20:35:17.305 DRIVER « [RES] [SendData] was sent: true 20:35:17.319 SERIAL « 0x010700138300000169 (9 bytes) 20:35:17.319 SERIAL » [ACK] (0x06) 20:35:17.320 DRIVER « [REQ] [SendData] callback id: 131 transmit status: OK 20:35:17.330 SERIAL « 0x0110000400050a3202211c000204b400005b (18 bytes) 20:35:17.330 CNTRLR [Node 005] [Meter] value[66305]: metadata updated [Endpoint 0] 20:35:17.331 CNTRLR [Node 005] [Meter] previousValue[66305]: metadata updated [Endpoint 0] 20:35:17.332 CNTRLR [Node 005] [Meter] deltaTime[66305]: metadata updated [Endpoint 0] 20:35:17.332 CNTRLR [Node 005] [+] [Meter] value[66305]: 132276 [Endpoint 0] 20:35:17.333 CNTRLR [Node 005] [+] [Meter] deltaTime[66305]: 0 [Endpoint 0] 20:35:17.333 SERIAL » [ACK] (0x06) 20:35:17.335 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: Pulse count rate type: Consumed value: 132276 time delta: 0 seconds 20:35:17.338 SERIAL » 0x010a00130603320158258429 (12 bytes) 20:35:17.338 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 132 └─[MeterCCGet] rate type: Consumed duration: Pulse count 20:35:17.338 CNTRLR » [Node 005] querying meter value (type = Electric, scale = V, rate type = Consu med)... 20:35:17.342 SERIAL « [ACK] (0x06) 20:35:17.343 SERIAL « 0x0104011301e8 (6 bytes) 20:35:17.344 SERIAL » [ACK] (0x06) 20:35:17.345 DRIVER « [RES] [SendData] was sent: true 20:35:17.358 SERIAL « 0x01070013840000016e (9 bytes) 20:35:17.358 SERIAL » [ACK] (0x06) 20:35:17.359 DRIVER « [REQ] [SendData] callback id: 132 transmit status: OK 20:35:17.369 SERIAL « 0x0110000400060a3202211c000032aa000072 (18 bytes) 20:35:17.369 CNTRLR [Node 006] [Meter] value[66305]: metadata updated [Endpoint 0] 20:35:17.370 CNTRLR [Node 006] [Meter] previousValue[66305]: metadata updated [Endpoint 0] 20:35:17.370 CNTRLR [Node 006] [Meter] deltaTime[66305]: metadata updated [Endpoint 0] 20:35:17.371 CNTRLR [Node 006] [+] [Meter] value[66305]: 12970 [Endpoint 0] 20:35:17.371 CNTRLR [Node 006] [+] [Meter] deltaTime[66305]: 0 [Endpoint 0] 20:35:17.374 SERIAL » [ACK] (0x06) 20:35:17.375 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: Pulse count rate type: Consumed value: 12970 time delta: 0 seconds 20:35:17.377 SERIAL » 0x010a0013020370050825853a (12 bytes) 20:35:17.377 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 133 └─[ConfigurationCCGet] parameter #: 8 20:35:17.377 CNTRLR » [Node 006] querying meter value (type = Electric, scale = V, rate type = Consu med)... 20:35:17.380 SERIAL « [ACK] (0x06) 20:35:17.382 SERIAL « 0x0104011301e8 (6 bytes) 20:35:17.383 SERIAL » [ACK] (0x06) 20:35:17.383 DRIVER « [RES] [SendData] was sent: true 20:35:17.402 SERIAL « 0x01070013850000036d (9 bytes) 20:35:17.402 SERIAL » [ACK] (0x06) 20:35:17.403 DRIVER « [REQ] [SendData] callback id: 133 transmit status: OK 20:35:17.426 SERIAL « 0x010c00040002067006080200008f (14 bytes) 20:35:17.428 CNTRLR [Node 002] [+] [Configuration] 8: 0 20:35:17.429 SERIAL » [ACK] (0x06) 20:35:17.430 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 2 value: 0 20:35:17.435 SERIAL » 0x010a00131303700514258634 (12 bytes) 20:35:17.436 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 134 └─[ConfigurationCCGet] parameter #: 20 20:35:17.436 CNTRLR « [Node 002] parameter #8 has value: 0 20:35:17.436 CNTRLR » [Node 002] querying parameter #9 value... 20:35:17.440 SERIAL « [ACK] (0x06) 20:35:17.442 SERIAL « 0x0104011301e8 (6 bytes) 20:35:17.442 SERIAL » [ACK] (0x06) 20:35:17.444 DRIVER « [RES] [SendData] was sent: true 20:35:17.583 SERIAL « 0x010700138600000f62 (9 bytes) 20:35:17.583 SERIAL » [ACK] (0x06) 20:35:17.584 DRIVER « [REQ] [SendData] callback id: 134 transmit status: OK 20:35:17.716 SERIAL « 0x010b0004001305700614010085 (13 bytes) 20:35:17.718 CNTRLR [Node 019] [+] [Configuration] 20: 0 20:35:17.719 SERIAL » [ACK] (0x06) 20:35:17.720 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 0 20:35:17.721 SERIAL » 0x010a0013120332014825872e (12 bytes) 20:35:17.721 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 135 └─[MeterCCGet] rate type: Consumed duration: kVAh 20:35:17.721 CNTRLR « [Node 019] parameter #20 has value: 0 20:35:17.721 CNTRLR » [Node 019] querying parameter #21 value... 20:35:17.724 SERIAL « [ACK] (0x06) 20:35:17.726 SERIAL « 0x0104011301e8 (6 bytes) 20:35:17.726 SERIAL » [ACK] (0x06) 20:35:17.726 DRIVER « [RES] [SendData] was sent: true 20:35:17.844 SERIAL « 0x010700138700000c60 (9 bytes) 20:35:17.845 SERIAL » [ACK] (0x06) 20:35:17.845 DRIVER « [REQ] [SendData] callback id: 135 transmit status: OK 20:35:17.856 SERIAL « 0x0114000400120e3202214c000003654c2100000361c7 (22 bytes) 20:35:17.856 CNTRLR [Node 018] [Meter] value[65793]: metadata updated [Endpoint 0] 20:35:17.857 CNTRLR [Node 018] [Meter] previousValue[65793]: metadata updated [Endpoint 0] 20:35:17.858 CNTRLR [Node 018] [Meter] deltaTime[65793]: metadata updated [Endpoint 0] 20:35:17.858 CNTRLR [Node 018] [+] [Meter] value[65793]: 8.69 [Endpoint 0] 20:35:17.859 CNTRLR [Node 018] [+] [Meter] previousValue[65793]: 8.65 [Endpoint 0] 20:35:17.859 CNTRLR [Node 018] [+] [Meter] deltaTime[65793]: 19489 [Endpoint 0] 20:35:17.860 SERIAL » [ACK] (0x06) 20:35:17.861 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kVAh rate type: Consumed value: 8.69 time delta: 19489 seconds prev. value: 8.65 20:35:17.864 SERIAL » 0x010a0013140370050525882c (12 bytes) 20:35:17.864 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 136 └─[ConfigurationCCGet] parameter #: 5 20:35:17.865 CNTRLR » [Node 018] querying meter value (type = Electric, scale = W, rate type = Consu med)... 20:35:17.869 SERIAL « [ACK] (0x06) 20:35:17.870 SERIAL « 0x0104011301e8 (6 bytes) 20:35:17.870 SERIAL » [ACK] (0x06) 20:35:17.870 DRIVER « [RES] [SendData] was sent: true 20:35:17.889 SERIAL « 0x010700138800000360 (9 bytes) 20:35:17.890 SERIAL » [ACK] (0x06) 20:35:17.890 DRIVER « [REQ] [SendData] callback id: 136 transmit status: OK 20:35:17.914 SERIAL « 0x010b0004001405700605010192 (13 bytes) 20:35:17.916 CNTRLR [Node 020] [+] [Configuration] 5: 1 20:35:17.917 SERIAL » [ACK] (0x06) 20:35:17.918 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 1 value: 1 20:35:17.931 SERIAL » 0x0109001315027502258929 (11 bytes) 20:35:17.931 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 137 └─[ProtectionCCGet] 20:35:17.932 CNTRLR « [Node 020] parameter #5 has value: 1 20:35:17.932 CNTRLR » [Node 020] querying parameter #6 value... 20:35:17.936 SERIAL « [ACK] (0x06) 20:35:17.937 SERIAL « 0x0104011301e8 (6 bytes) 20:35:17.937 SERIAL » [ACK] (0x06) 20:35:17.938 DRIVER « [RES] [SendData] was sent: true 20:35:19.302 SERIAL « 0x0107001389000089eb (9 bytes) 20:35:19.303 SERIAL » [ACK] (0x06) 20:35:19.303 DRIVER « [REQ] [SendData] callback id: 137 transmit status: OK 20:35:19.377 SERIAL « 0x0109000400150375030092 (11 bytes) 20:35:19.379 CNTRLR [Node 021] [+] [Protection] local: 0 [Endpoint 0] 20:35:19.379 SERIAL » [ACK] (0x06) 20:35:19.380 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected 20:35:19.382 SERIAL » 0x0109001316027502258a29 (11 bytes) 20:35:19.382 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 138 └─[ProtectionCCGet] 20:35:19.382 CNTRLR « [Node 021] received protection status: local: Unprotected 20:35:19.382 CNTRLR [Node 021] [+] [Protection] interviewComplete: true [Endpoint 0] [internal] 20:35:19.384 SERIAL « [ACK] (0x06) 20:35:19.386 CNTRLR [Node 021] MultilevelSensorCC: doing a complete interview... 20:35:19.386 CNTRLR » [Node 021] retrieving supported sensor types... 20:35:19.401 SERIAL « 0x0104011301e8 (6 bytes) 20:35:19.401 SERIAL » [ACK] (0x06) 20:35:19.402 DRIVER « [RES] [SendData] was sent: true 20:35:21.134 SERIAL « 0x010700138a0000afce (9 bytes) 20:35:21.135 SERIAL » [ACK] (0x06) 20:35:21.135 DRIVER « [REQ] [SendData] callback id: 138 transmit status: OK 20:35:21.217 SERIAL « 0x0109000400160375030091 (11 bytes) 20:35:21.218 CNTRLR [Node 022] [+] [Protection] local: 0 [Endpoint 0] 20:35:21.219 SERIAL » [ACK] (0x06) 20:35:21.220 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected 20:35:21.223 SERIAL » 0x0109001317027502258b29 (11 bytes) 20:35:21.223 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 139 └─[ProtectionCCGet] 20:35:21.223 CNTRLR « [Node 022] received protection status: local: Unprotected 20:35:21.224 CNTRLR [Node 022] [+] [Protection] interviewComplete: true [Endpoint 0] [internal] 20:35:21.232 SERIAL « [ACK] (0x06) 20:35:21.234 SERIAL « 0x0104011301e8 (6 bytes) 20:35:21.234 SERIAL » [ACK] (0x06) 20:35:21.235 DRIVER « [RES] [SendData] was sent: true 20:35:21.237 CNTRLR [Node 022] MultilevelSensorCC: doing a complete interview... 20:35:21.237 CNTRLR » [Node 022] retrieving supported sensor types... 20:35:22.708 SERIAL « 0x010700138b000094f4 (9 bytes) 20:35:22.708 SERIAL » [ACK] (0x06) 20:35:22.709 DRIVER « [REQ] [SendData] callback id: 139 transmit status: OK 20:35:22.786 SERIAL « 0x0109000400170375030090 (11 bytes) 20:35:22.787 CNTRLR [Node 023] [+] [Protection] local: 0 [Endpoint 0] 20:35:22.787 SERIAL » [ACK] (0x06) 20:35:22.788 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected 20:35:22.791 SERIAL » 0x0109001318027502258c21 (11 bytes) 20:35:22.791 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 140 └─[ProtectionCCGet] 20:35:22.791 CNTRLR « [Node 023] received protection status: local: Unprotected 20:35:22.791 CNTRLR [Node 023] [+] [Protection] interviewComplete: true [Endpoint 0] [internal] 20:35:22.794 SERIAL « [ACK] (0x06) 20:35:22.795 CNTRLR [Node 023] MultilevelSensorCC: doing a complete interview... 20:35:22.795 CNTRLR » [Node 023] retrieving supported sensor types... 20:35:22.798 SERIAL « 0x0104011301e8 (6 bytes) 20:35:22.798 SERIAL » [ACK] (0x06) 20:35:22.798 DRIVER « [RES] [SendData] was sent: true 20:35:24.208 SERIAL « 0x010700138c00008dea (9 bytes) 20:35:24.208 SERIAL » [ACK] (0x06) 20:35:24.209 DRIVER « [REQ] [SendData] callback id: 140 transmit status: OK 20:35:24.287 SERIAL « 0x010900040018037503009f (11 bytes) 20:35:24.288 CNTRLR [Node 024] [+] [Protection] local: 0 [Endpoint 0] 20:35:24.289 SERIAL » [ACK] (0x06) 20:35:24.290 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected 20:35:24.293 SERIAL » 0x010a00131a03700514258d36 (12 bytes) 20:35:24.294 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 141 └─[ConfigurationCCGet] parameter #: 20 20:35:24.294 CNTRLR « [Node 024] received protection status: local: Unprotected 20:35:24.295 CNTRLR [Node 024] [+] [Protection] interviewComplete: true [Endpoint 0] [internal] 20:35:24.302 SERIAL « [ACK] (0x06) 20:35:24.303 SERIAL « 0x0104011301e8 (6 bytes) 20:35:24.303 SERIAL » [ACK] (0x06) 20:35:24.304 DRIVER « [RES] [SendData] was sent: true 20:35:24.306 CNTRLR [Node 024] MultilevelSensorCC: doing a complete interview... 20:35:24.306 CNTRLR » [Node 024] retrieving supported sensor types... 20:35:24.400 SERIAL « 0x010700138d00000b6d (9 bytes) 20:35:24.401 SERIAL » [ACK] (0x06) 20:35:24.401 DRIVER « [REQ] [SendData] callback id: 141 transmit status: OK 20:35:24.471 SERIAL « 0x010b0004001a0570061401008c (13 bytes) 20:35:24.473 CNTRLR [Node 026] [+] [Configuration] 20: 0 20:35:24.474 SERIAL » [ACK] (0x06) 20:35:24.475 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 0 20:35:24.478 SERIAL » 0x010a00131c03700514258e33 (12 bytes) 20:35:24.478 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 142 └─[ConfigurationCCGet] parameter #: 20 20:35:24.479 CNTRLR « [Node 026] parameter #20 has value: 0 20:35:24.479 CNTRLR » [Node 026] querying parameter #21 value... 20:35:24.483 SERIAL « [ACK] (0x06) 20:35:24.484 SERIAL « 0x0104011301e8 (6 bytes) 20:35:24.485 SERIAL » [ACK] (0x06) 20:35:24.485 DRIVER « [RES] [SendData] was sent: true 20:35:24.554 SERIAL « 0x010700138e00000762 (9 bytes) 20:35:24.555 SERIAL » [ACK] (0x06) 20:35:24.556 DRIVER « [REQ] [SendData] callback id: 142 transmit status: OK 20:35:24.564 SERIAL « 0x010b0004001c0570061401008a (13 bytes) 20:35:24.566 CNTRLR [Node 028] [+] [Configuration] 20: 0 20:35:24.567 SERIAL » [ACK] (0x06) 20:35:24.568 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 0 20:35:24.576 SERIAL » 0x010a00130303700517258f2e (12 bytes) 20:35:24.576 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 143 └─[ConfigurationCCGet] parameter #: 23 20:35:24.577 CNTRLR « [Node 028] parameter #20 has value: 0 20:35:24.577 CNTRLR » [Node 028] querying parameter #21 value... 20:35:24.582 SERIAL « [ACK] (0x06) 20:35:24.584 SERIAL « 0x0104011301e8 (6 bytes) 20:35:24.584 SERIAL » [ACK] (0x06) 20:35:24.585 DRIVER « [RES] [SendData] was sent: true 20:35:24.601 SERIAL « 0x010700138f00000367 (9 bytes) 20:35:24.602 SERIAL » [ACK] (0x06) 20:35:24.602 DRIVER « [REQ] [SendData] callback id: 143 transmit status: OK 20:35:24.614 SERIAL « 0x010b0004000305700617010690 (13 bytes) 20:35:24.615 CNTRLR [Node 003] [+] [Configuration] 23: 6 20:35:24.616 SERIAL » [ACK] (0x06) 20:35:24.616 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 23 value size: 1 value: 6 20:35:24.619 SERIAL » 0x010a00130503320160259006 (12 bytes) 20:35:24.619 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 144 └─[MeterCCGet] rate type: Consumed duration: V 20:35:24.619 CNTRLR « [Node 003] parameter #23 has value: 6 20:35:24.620 CNTRLR » [Node 003] querying parameter #24 value... 20:35:24.622 SERIAL « [ACK] (0x06) 20:35:24.625 SERIAL « 0x0104011301e8 (6 bytes) 20:35:24.625 SERIAL » [ACK] (0x06) 20:35:24.626 DRIVER « [RES] [SendData] was sent: true 20:35:24.639 SERIAL « 0x01070013900000017a (9 bytes) 20:35:24.640 SERIAL » [ACK] (0x06) 20:35:24.640 DRIVER « [REQ] [SendData] callback id: 144 transmit status: OK 20:35:24.650 SERIAL « 0x010e00040005083202a122090d00004f (16 bytes) 20:35:24.651 CNTRLR [Node 005] [Meter] value[66561]: metadata updated [Endpoint 0] 20:35:24.652 CNTRLR [Node 005] [Meter] previousValue[66561]: metadata updated [Endpoint 0] 20:35:24.652 CNTRLR [Node 005] [Meter] deltaTime[66561]: metadata updated [Endpoint 0] 20:35:24.653 CNTRLR [Node 005] [+] [Meter] value[66561]: 231.7 [Endpoint 0] 20:35:24.653 CNTRLR [Node 005] [+] [Meter] deltaTime[66561]: 0 [Endpoint 0] 20:35:24.654 SERIAL » [ACK] (0x06) 20:35:24.655 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: V rate type: Consumed value: 231.7 time delta: 0 seconds 20:35:24.658 SERIAL » 0x010a00130603320160259104 (12 bytes) 20:35:24.658 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 145 └─[MeterCCGet] rate type: Consumed duration: V 20:35:24.659 CNTRLR » [Node 005] querying meter value (type = Electric, scale = A, rate type = Consu med)... 20:35:24.662 SERIAL « [ACK] (0x06) 20:35:24.664 SERIAL « 0x0104011301e8 (6 bytes) 20:35:24.664 SERIAL » [ACK] (0x06) 20:35:24.666 DRIVER « [RES] [SendData] was sent: true 20:35:24.679 SERIAL « 0x01070013910000017b (9 bytes) 20:35:24.679 SERIAL » [ACK] (0x06) 20:35:24.680 DRIVER « [REQ] [SendData] callback id: 145 transmit status: OK 20:35:24.689 SERIAL « 0x010e00040006083202a122093a00007b (16 bytes) 20:35:24.690 CNTRLR [Node 006] [Meter] value[66561]: metadata updated [Endpoint 0] 20:35:24.691 CNTRLR [Node 006] [Meter] previousValue[66561]: metadata updated [Endpoint 0] 20:35:24.691 CNTRLR [Node 006] [Meter] deltaTime[66561]: metadata updated [Endpoint 0] 20:35:24.692 CNTRLR [Node 006] [+] [Meter] value[66561]: 236.2 [Endpoint 0] 20:35:24.692 CNTRLR [Node 006] [+] [Meter] deltaTime[66561]: 0 [Endpoint 0] 20:35:24.692 SERIAL » [ACK] (0x06) 20:35:24.696 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: V rate type: Consumed value: 236.2 time delta: 0 seconds 20:35:24.698 SERIAL » 0x010a0013020370050925922c (12 bytes) 20:35:24.699 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 146 └─[ConfigurationCCGet] parameter #: 9 20:35:24.699 CNTRLR » [Node 006] querying meter value (type = Electric, scale = A, rate type = Consu med)... 20:35:24.702 SERIAL « [ACK] (0x06) 20:35:24.705 SERIAL « 0x0104011301e8 (6 bytes) 20:35:24.705 SERIAL » [ACK] (0x06) 20:35:24.706 DRIVER « [RES] [SendData] was sent: true 20:35:24.748 SERIAL « 0x01070013920000047d (9 bytes) 20:35:24.748 SERIAL » [ACK] (0x06) 20:35:24.749 DRIVER « [REQ] [SendData] callback id: 146 transmit status: OK 20:35:24.779 SERIAL « 0x010b0004000205700609010089 (13 bytes) 20:35:24.781 CNTRLR [Node 002] [+] [Configuration] 9: 0 20:35:24.782 SERIAL » [ACK] (0x06) 20:35:24.783 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 1 value: 0 20:35:24.785 SERIAL » 0x010a00131303700515259320 (12 bytes) 20:35:24.786 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 147 └─[ConfigurationCCGet] parameter #: 21 20:35:24.786 CNTRLR « [Node 002] parameter #9 has value: 0 20:35:24.786 CNTRLR [Node 002] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 20:35:24.791 SERIAL « [ACK] (0x06) 20:35:24.793 SERIAL « 0x0104011301e8 (6 bytes) 20:35:24.794 SERIAL » [ACK] (0x06) 20:35:24.794 DRIVER « [RES] [SendData] was sent: true 20:35:24.796 CNTRLR [Node 002] ProtectionCC: doing a complete interview... 20:35:24.796 CNTRLR » [Node 002] querying protection capabilities... 20:35:24.835 SERIAL « 0x010c0004001c063105042202c23f (14 bytes) 20:35:24.836 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:35:24.837 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 57.4 => 70.6 [Endpoint 0] 20:35:24.837 SERIAL » [ACK] (0x06) 20:35:24.838 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 70.6 20:35:24.874 SERIAL « 0x010c0004001c063105042202c23f (14 bytes) 20:35:24.874 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:35:24.875 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 70.6 => 70.6 [Endpoint 0] 20:35:24.876 SERIAL » [ACK] (0x06) 20:35:24.877 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 70.6 20:35:24.941 SERIAL « 0x010700139300001068 (9 bytes) 20:35:24.941 SERIAL » [ACK] (0x06) 20:35:24.942 DRIVER « [REQ] [SendData] callback id: 147 transmit status: OK 20:35:25.068 SERIAL « 0x010c000400130670061502012cae (14 bytes) 20:35:25.070 CNTRLR [Node 019] [+] [Configuration] 21: 300 20:35:25.071 SERIAL » [ACK] (0x06) 20:35:25.072 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 21 value size: 2 value: 300 20:35:25.075 SERIAL » 0x010a00131203320150259425 (12 bytes) 20:35:25.075 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 148 └─[MeterCCGet] rate type: Consumed duration: W 20:35:25.076 CNTRLR « [Node 019] parameter #21 has value: 300 20:35:25.076 CNTRLR » [Node 019] querying parameter #22 value... 20:35:25.080 SERIAL « [ACK] (0x06) 20:35:25.081 SERIAL « 0x0104011301e8 (6 bytes) 20:35:25.082 SERIAL » [ACK] (0x06) 20:35:25.083 DRIVER « [RES] [SendData] was sent: true 20:35:25.194 SERIAL « 0x010700139400000c73 (9 bytes) 20:35:25.195 SERIAL » [ACK] (0x06) 20:35:25.195 DRIVER « [REQ] [SendData] callback id: 148 transmit status: OK 20:35:25.205 SERIAL « 0x0110000400120a32022134000000010000d7 (18 bytes) 20:35:25.206 CNTRLR [Node 018] [~] [Meter] value[66049]: 0.1 => 0.1 [Endpoint 0] 20:35:25.207 CNTRLR [Node 018] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:35:25.207 SERIAL » [ACK] (0x06) 20:35:25.209 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0.1 time delta: 0 seconds 20:35:25.212 SERIAL » 0x010a00131403700506259532 (12 bytes) 20:35:25.212 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 149 └─[ConfigurationCCGet] parameter #: 6 20:35:25.213 CNTRLR » [Node 018] querying meter value (type = Electric, scale = Pulse count, rate ty pe = Consumed)... 20:35:25.216 SERIAL « [ACK] (0x06) 20:35:25.219 SERIAL « 0x0104011301e8 (6 bytes) 20:35:25.219 SERIAL » [ACK] (0x06) 20:35:25.220 DRIVER « [RES] [SendData] was sent: true 20:35:25.237 SERIAL « 0x01070013950000027c (9 bytes) 20:35:25.238 SERIAL » [ACK] (0x06) 20:35:25.238 DRIVER « [REQ] [SendData] callback id: 149 transmit status: OK 20:35:25.261 SERIAL « 0x010b0004001405700606010191 (13 bytes) 20:35:25.263 CNTRLR [Node 020] [+] [Configuration] 6: 1 20:35:25.264 SERIAL » [ACK] (0x06) 20:35:25.264 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 1 value: 1 20:35:25.268 SERIAL » 0x0109001315023101259671 (11 bytes) 20:35:25.268 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 150 └─[MultilevelSensorCCGetSupportedSensor] 20:35:25.268 CNTRLR « [Node 020] parameter #6 has value: 1 20:35:25.269 CNTRLR » [Node 020] querying parameter #7 value... 20:35:25.272 SERIAL « [ACK] (0x06) 20:35:25.274 SERIAL « 0x0104011301e8 (6 bytes) 20:35:25.274 SERIAL » [ACK] (0x06) 20:35:25.276 DRIVER « [RES] [SendData] was sent: true 20:35:26.675 SERIAL « 0x010700139600008cf1 (9 bytes) 20:35:26.675 SERIAL » [ACK] (0x06) 20:35:26.676 DRIVER « [REQ] [SendData] callback id: 150 transmit status: OK 20:35:26.754 SERIAL « 0x01090004001503310201d6 (11 bytes) 20:35:26.756 CNTRLR [Node 021] [+] [Multilevel Sensor] supportedSensorType [Endpoint 0] [internal] s: 1 20:35:26.756 SERIAL » [ACK] (0x06) 20:35:26.757 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedSensorReport] supported sensor types: · Air temperature 20:35:26.760 SERIAL » 0x0109001316023101259773 (11 bytes) 20:35:26.760 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 151 └─[MultilevelSensorCCGetSupportedSensor] 20:35:26.760 CNTRLR « [Node 021] received supported sensor types: · Air temperature 20:35:26.760 CNTRLR » [Node 021] querying supported scales for Air temperature sensor 20:35:26.761 SERIAL « [ACK] (0x06) 20:35:26.765 SERIAL « 0x0104011301e8 (6 bytes) 20:35:26.765 SERIAL » [ACK] (0x06) 20:35:26.765 DRIVER « [RES] [SendData] was sent: true 20:35:28.418 SERIAL « 0x01070013970000a5d9 (9 bytes) 20:35:28.418 SERIAL » [ACK] (0x06) 20:35:28.419 DRIVER « [REQ] [SendData] callback id: 151 transmit status: OK 20:35:28.500 SERIAL « 0x01090004001603310201d5 (11 bytes) 20:35:28.501 CNTRLR [Node 022] [+] [Multilevel Sensor] supportedSensorType [Endpoint 0] [internal] s: 1 20:35:28.501 SERIAL » [ACK] (0x06) 20:35:28.502 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedSensorReport] supported sensor types: · Air temperature 20:35:28.504 SERIAL » 0x010900131702310125987d (11 bytes) 20:35:28.505 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 152 └─[MultilevelSensorCCGetSupportedSensor] 20:35:28.505 CNTRLR « [Node 022] received supported sensor types: · Air temperature 20:35:28.505 CNTRLR » [Node 022] querying supported scales for Air temperature sensor 20:35:28.506 SERIAL « [ACK] (0x06) 20:35:28.510 SERIAL « 0x0104011301e8 (6 bytes) 20:35:28.510 SERIAL » [ACK] (0x06) 20:35:28.511 DRIVER « [RES] [SendData] was sent: true 20:35:29.952 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:35:29.952 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:35:29.953 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:35:29.954 SERIAL » [ACK] (0x06) 20:35:29.955 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:35:29.975 SERIAL « 0x0107001398000093e0 (9 bytes) 20:35:29.975 SERIAL » [ACK] (0x06) 20:35:29.975 DRIVER « [REQ] [SendData] callback id: 152 transmit status: OK 20:35:30.005 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:35:30.005 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:35:30.006 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:35:30.007 SERIAL » [ACK] (0x06) 20:35:30.008 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:35:30.052 SERIAL « 0x01090004001703310201d4 (11 bytes) 20:35:30.053 CNTRLR [Node 023] [+] [Multilevel Sensor] supportedSensorType [Endpoint 0] [internal] s: 1 20:35:30.053 SERIAL » [ACK] (0x06) 20:35:30.054 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedSensorReport] supported sensor types: · Air temperature 20:35:30.056 SERIAL » 0x0109001318023101259973 (11 bytes) 20:35:30.057 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 153 └─[MultilevelSensorCCGetSupportedSensor] 20:35:30.057 CNTRLR « [Node 023] received supported sensor types: · Air temperature 20:35:30.057 CNTRLR » [Node 023] querying supported scales for Air temperature sensor 20:35:30.060 SERIAL « [ACK] (0x06) 20:35:30.063 SERIAL « 0x0104011301e8 (6 bytes) 20:35:30.063 SERIAL » [ACK] (0x06) 20:35:30.064 DRIVER « [RES] [SendData] was sent: true 20:35:31.530 SERIAL « 0x0107001399000094e6 (9 bytes) 20:35:31.531 SERIAL » [ACK] (0x06) 20:35:31.531 DRIVER « [REQ] [SendData] callback id: 153 transmit status: OK 20:35:31.612 SERIAL « 0x01090004001803310201db (11 bytes) 20:35:31.613 CNTRLR [Node 024] [+] [Multilevel Sensor] supportedSensorType [Endpoint 0] [internal] s: 1 20:35:31.613 SERIAL » [ACK] (0x06) 20:35:31.613 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedSensorReport] supported sensor types: · Air temperature 20:35:31.616 SERIAL » 0x010a00131a03700515259a20 (12 bytes) 20:35:31.616 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 154 └─[ConfigurationCCGet] parameter #: 21 20:35:31.616 CNTRLR « [Node 024] received supported sensor types: · Air temperature 20:35:31.616 CNTRLR » [Node 024] querying supported scales for Air temperature sensor 20:35:31.617 SERIAL « [ACK] (0x06) 20:35:31.622 SERIAL « 0x0104011301e8 (6 bytes) 20:35:31.622 SERIAL » [ACK] (0x06) 20:35:31.622 DRIVER « [RES] [SendData] was sent: true 20:35:31.730 SERIAL « 0x010700139a00000c7d (9 bytes) 20:35:31.730 SERIAL » [ACK] (0x06) 20:35:31.731 DRIVER « [REQ] [SendData] callback id: 154 transmit status: OK 20:35:31.802 SERIAL « 0x010c0004001a0670061502012ca7 (14 bytes) 20:35:31.803 CNTRLR [Node 026] [+] [Configuration] 21: 300 20:35:31.804 SERIAL » [ACK] (0x06) 20:35:31.805 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 21 value size: 2 value: 300 20:35:31.808 SERIAL » 0x010a00131c03700515259b27 (12 bytes) 20:35:31.808 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 155 └─[ConfigurationCCGet] parameter #: 21 20:35:31.808 CNTRLR « [Node 026] parameter #21 has value: 300 20:35:31.809 CNTRLR » [Node 026] querying parameter #22 value... 20:35:31.811 SERIAL « [ACK] (0x06) 20:35:31.813 SERIAL « 0x0104011301e8 (6 bytes) 20:35:31.814 SERIAL » [ACK] (0x06) 20:35:31.814 DRIVER « [RES] [SendData] was sent: true 20:35:31.884 SERIAL « 0x010700139b00000777 (9 bytes) 20:35:31.885 SERIAL » [ACK] (0x06) 20:35:31.885 DRIVER « [REQ] [SendData] callback id: 155 transmit status: OK 20:35:31.895 SERIAL « 0x010c0004001c0670061502012ca1 (14 bytes) 20:35:31.896 CNTRLR [Node 028] [+] [Configuration] 21: 300 20:35:31.898 SERIAL » [ACK] (0x06) 20:35:31.899 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 21 value size: 2 value: 300 20:35:31.904 SERIAL » 0x010a00130303700518259c32 (12 bytes) 20:35:31.905 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 156 └─[ConfigurationCCGet] parameter #: 24 20:35:31.905 CNTRLR « [Node 028] parameter #21 has value: 300 20:35:31.905 CNTRLR » [Node 028] querying parameter #22 value... 20:35:31.909 SERIAL « [ACK] (0x06) 20:35:31.912 SERIAL « 0x0104011301e8 (6 bytes) 20:35:31.912 SERIAL » [ACK] (0x06) 20:35:31.913 DRIVER « [RES] [SendData] was sent: true 20:35:31.930 SERIAL « 0x010700139c00000374 (9 bytes) 20:35:31.930 SERIAL » [ACK] (0x06) 20:35:31.931 DRIVER « [REQ] [SendData] callback id: 156 transmit status: OK 20:35:31.943 SERIAL « 0x010c00040003067006180200ff61 (14 bytes) 20:35:31.944 CNTRLR [Node 003] [+] [Configuration] 24: 255 20:35:31.945 SERIAL » [ACK] (0x06) 20:35:31.946 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 24 value size: 2 value: 255 20:35:31.949 SERIAL » 0x010a00130503320168259d03 (12 bytes) 20:35:31.949 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 157 └─[MeterCCGet] rate type: Consumed duration: A 20:35:31.950 CNTRLR « [Node 003] parameter #24 has value: 255 20:35:31.950 CNTRLR » [Node 003] querying parameter #30 value... 20:35:31.955 SERIAL « [ACK] (0x06) 20:35:31.961 SERIAL « 0x0104011301e8 (6 bytes) 20:35:31.961 SERIAL » [ACK] (0x06) 20:35:31.962 DRIVER « [RES] [SendData] was sent: true 20:35:31.970 SERIAL « 0x010700139d00000274 (9 bytes) 20:35:31.970 SERIAL » [ACK] (0x06) 20:35:31.970 DRIVER « [REQ] [SendData] callback id: 157 transmit status: OK 20:35:31.980 SERIAL « 0x010e00040005083202a14a0000000023 (16 bytes) 20:35:31.981 CNTRLR [Node 005] [Meter] value[66817]: metadata updated [Endpoint 0] 20:35:31.981 CNTRLR [Node 005] [Meter] previousValue[66817]: metadata updated [Endpoint 0] 20:35:31.981 CNTRLR [Node 005] [Meter] deltaTime[66817]: metadata updated [Endpoint 0] 20:35:31.982 CNTRLR [Node 005] [+] [Meter] value[66817]: 0 [Endpoint 0] 20:35:31.982 CNTRLR [Node 005] [+] [Meter] deltaTime[66817]: 0 [Endpoint 0] 20:35:31.982 SERIAL » [ACK] (0x06) 20:35:31.983 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: A rate type: Consumed value: 0 time delta: 0 seconds 20:35:31.984 SERIAL » 0x010a00130603320168259e03 (12 bytes) 20:35:31.984 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 158 └─[MeterCCGet] rate type: Consumed duration: A 20:35:31.985 CNTRLR » [Node 005] querying meter value (type = Electric, scale = Power Factor, rate t ype = Consumed)... 20:35:31.987 SERIAL « [ACK] (0x06) 20:35:31.990 SERIAL « 0x0104011301e8 (6 bytes) 20:35:31.990 SERIAL » [ACK] (0x06) 20:35:31.990 DRIVER « [RES] [SendData] was sent: true 20:35:32.005 SERIAL « 0x010700139e00000277 (9 bytes) 20:35:32.005 SERIAL » [ACK] (0x06) 20:35:32.005 DRIVER « [REQ] [SendData] callback id: 158 transmit status: OK 20:35:32.015 SERIAL « 0x010e00040006083202a14a0000000020 (16 bytes) 20:35:32.015 CNTRLR [Node 006] [Meter] value[66817]: metadata updated [Endpoint 0] 20:35:32.016 CNTRLR [Node 006] [Meter] previousValue[66817]: metadata updated [Endpoint 0] 20:35:32.016 CNTRLR [Node 006] [Meter] deltaTime[66817]: metadata updated [Endpoint 0] 20:35:32.016 CNTRLR [Node 006] [+] [Meter] value[66817]: 0 [Endpoint 0] 20:35:32.017 CNTRLR [Node 006] [+] [Meter] deltaTime[66817]: 0 [Endpoint 0] 20:35:32.017 SERIAL » [ACK] (0x06) 20:35:32.018 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: A rate type: Consumed value: 0 time delta: 0 seconds 20:35:32.020 SERIAL » 0x0109001302027504259f2e (11 bytes) 20:35:32.020 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 159 └─[ProtectionCCSupportedGet] 20:35:32.020 CNTRLR » [Node 006] querying meter value (type = Electric, scale = Power Factor, rate t ype = Consumed)... 20:35:32.022 SERIAL « [ACK] (0x06) 20:35:32.025 SERIAL « 0x0104011301e8 (6 bytes) 20:35:32.026 SERIAL » [ACK] (0x06) 20:35:32.027 DRIVER « [RES] [SendData] was sent: true 20:35:32.045 SERIAL « 0x010700139f00000276 (9 bytes) 20:35:32.045 SERIAL » [ACK] (0x06) 20:35:32.045 DRIVER « [REQ] [SendData] callback id: 159 transmit status: OK 20:35:32.070 SERIAL « 0x010d00040002077505030700070080 (15 bytes) 20:35:32.071 CNTRLR [Node 002] [+] [Protection] supportsExclusiveControl: [Endpoint 0] [internal] true 20:35:32.072 CNTRLR [Node 002] [+] [Protection] supportsTimeout: true [Endpoint 0] [internal] 20:35:32.072 CNTRLR [Node 002] [+] [Protection] supportedLocalStates: 0,1, [Endpoint 0] [internal] 2 20:35:32.072 CNTRLR [Node 002] [+] [Protection] supportedRFStates: 0,1,2 [Endpoint 0] [internal] 20:35:32.073 CNTRLR [Node 002] [Protection] local: metadata updated [Endpoint 0] 20:35:32.074 CNTRLR [Node 002] [Protection] rf: metadata updated [Endpoint 0] 20:35:32.074 SERIAL » [ACK] (0x06) 20:35:32.076 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[ProtectionCCSupportedReport] supports exclusive control: true supports timeout: true local protection states: · Unprotected · ProtectedBySequence · NoOperationPossible RF protection states: · Unprotected · NoControl · NoResponse 20:35:32.079 SERIAL » 0x010a0013130370051625a010 (12 bytes) 20:35:32.079 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 160 └─[ConfigurationCCGet] parameter #: 22 20:35:32.080 CNTRLR « [Node 002] received protection capabilities: exclusive control: true timeout: true local protection states: · Unprotected · ProtectedBySequence · NoOperationPossible RF protection states: · Unprotected · NoControl · NoResponse 20:35:32.080 CNTRLR » [Node 002] querying protection status... 20:35:32.084 SERIAL « [ACK] (0x06) 20:35:32.086 SERIAL « 0x0104011301e8 (6 bytes) 20:35:32.086 SERIAL » [ACK] (0x06) 20:35:32.088 DRIVER « [RES] [SendData] was sent: true 20:35:32.226 SERIAL « 0x01070013a000000e45 (9 bytes) 20:35:32.226 SERIAL » [ACK] (0x06) 20:35:32.227 DRIVER « [REQ] [SendData] callback id: 160 transmit status: OK 20:35:32.358 SERIAL « 0x010c00040013067006160201f475 (14 bytes) 20:35:32.360 CNTRLR [Node 019] [+] [Configuration] 22: 500 20:35:32.361 SERIAL » [ACK] (0x06) 20:35:32.362 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 500 20:35:32.367 SERIAL » 0x010a0013120332015825a118 (12 bytes) 20:35:32.368 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 161 └─[MeterCCGet] rate type: Consumed duration: Pulse count 20:35:32.368 CNTRLR « [Node 019] parameter #22 has value: 500 20:35:32.369 CNTRLR » [Node 019] querying parameter #23 value... 20:35:32.371 SERIAL « [ACK] (0x06) 20:35:32.373 SERIAL « 0x0104011301e8 (6 bytes) 20:35:32.374 SERIAL » [ACK] (0x06) 20:35:32.374 DRIVER « [RES] [SendData] was sent: true 20:35:32.484 SERIAL « 0x01070013a100000b41 (9 bytes) 20:35:32.484 SERIAL » [ACK] (0x06) 20:35:32.485 DRIVER « [REQ] [SendData] callback id: 161 transmit status: OK 20:35:32.495 SERIAL « 0x0110000400120a3202211c000341430000ff (18 bytes) 20:35:32.496 CNTRLR [Node 018] [Meter] value[66305]: metadata updated [Endpoint 0] 20:35:32.496 CNTRLR [Node 018] [Meter] previousValue[66305]: metadata updated [Endpoint 0] 20:35:32.497 CNTRLR [Node 018] [Meter] deltaTime[66305]: metadata updated [Endpoint 0] 20:35:32.497 CNTRLR [Node 018] [+] [Meter] value[66305]: 213315 [Endpoint 0] 20:35:32.498 CNTRLR [Node 018] [+] [Meter] deltaTime[66305]: 0 [Endpoint 0] 20:35:32.498 SERIAL » [ACK] (0x06) 20:35:32.500 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: Pulse count rate type: Consumed value: 213315 time delta: 0 seconds 20:35:32.502 SERIAL » 0x010a0013140370050725a204 (12 bytes) 20:35:32.503 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 162 └─[ConfigurationCCGet] parameter #: 7 20:35:32.503 CNTRLR » [Node 018] querying meter value (type = Electric, scale = V, rate type = Consu med)... 20:35:32.506 SERIAL « [ACK] (0x06) 20:35:32.509 SERIAL « 0x0104011301e8 (6 bytes) 20:35:32.509 SERIAL » [ACK] (0x06) 20:35:32.510 DRIVER « [RES] [SendData] was sent: true 20:35:32.528 SERIAL « 0x01070013a20000024b (9 bytes) 20:35:32.528 SERIAL » [ACK] (0x06) 20:35:32.528 DRIVER « [REQ] [SendData] callback id: 162 transmit status: OK 20:35:32.551 SERIAL « 0x010b0004001405700607010293 (13 bytes) 20:35:32.553 CNTRLR [Node 020] [+] [Configuration] 7: 2 20:35:32.554 SERIAL » [ACK] (0x06) 20:35:32.555 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 7 value size: 1 value: 2 20:35:32.558 SERIAL » 0x010a0013150331030125a345 (12 bytes) 20:35:32.558 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 163 └─[MultilevelSensorCCGetSupportedScale] sensor type: Air temperature 20:35:32.558 CNTRLR « [Node 020] parameter #7 has value: 2 20:35:32.559 CNTRLR » [Node 020] querying parameter #8 value... 20:35:32.562 SERIAL « [ACK] (0x06) 20:35:32.567 SERIAL « 0x0104011301e8 (6 bytes) 20:35:32.567 SERIAL » [ACK] (0x06) 20:35:32.568 DRIVER « [RES] [SendData] was sent: true 20:35:32.810 SERIAL « 0x010c0004001c06310504220239c4 (14 bytes) 20:35:32.811 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:35:32.812 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 70.6 => 56.9 [Endpoint 0] 20:35:32.812 SERIAL » [ACK] (0x06) 20:35:32.813 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 56.9 20:35:34.001 SERIAL « 0x01070013a3000090d8 (9 bytes) 20:35:34.001 SERIAL » [ACK] (0x06) 20:35:34.001 DRIVER « [REQ] [SendData] callback id: 163 transmit status: OK 20:35:34.077 SERIAL « 0x010a000400150431060101d7 (12 bytes) 20:35:34.079 CNTRLR [Node 021] [+] [Multilevel Sensor] supportedScales[1]: [Endpoint 0] [internal] 0 20:35:34.079 SERIAL » [ACK] (0x06) 20:35:34.080 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedScaleReport] sensor type: Air temperature supported scales: · Celsius 20:35:34.082 SERIAL » 0x010a0013160331030125a441 (12 bytes) 20:35:34.082 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 164 └─[MultilevelSensorCCGetSupportedScale] sensor type: Air temperature 20:35:34.082 CNTRLR « [Node 021] received supported scales: · Celsius 20:35:34.082 CNTRLR » [Node 021] querying Air temperature sensor reading... 20:35:34.084 SERIAL « [ACK] (0x06) 20:35:34.087 SERIAL « 0x0104011301e8 (6 bytes) 20:35:34.088 SERIAL » [ACK] (0x06) 20:35:34.088 DRIVER « [RES] [SendData] was sent: true 20:35:35.793 SERIAL « 0x01070013a40000abe4 (9 bytes) 20:35:35.793 SERIAL » [ACK] (0x06) 20:35:35.794 DRIVER « [REQ] [SendData] callback id: 164 transmit status: OK 20:35:35.873 SERIAL « 0x010a000400160431060101d4 (12 bytes) 20:35:35.874 CNTRLR [Node 022] [+] [Multilevel Sensor] supportedScales[1]: [Endpoint 0] [internal] 0 20:35:35.874 SERIAL » [ACK] (0x06) 20:35:35.874 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedScaleReport] sensor type: Air temperature supported scales: · Celsius 20:35:35.877 SERIAL » 0x010a0013170331030125a541 (12 bytes) 20:35:35.878 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 165 └─[MultilevelSensorCCGetSupportedScale] sensor type: Air temperature 20:35:35.878 CNTRLR « [Node 022] received supported scales: · Celsius 20:35:35.878 CNTRLR » [Node 022] querying Air temperature sensor reading... 20:35:35.881 SERIAL « [ACK] (0x06) 20:35:35.883 SERIAL « 0x0104011301e8 (6 bytes) 20:35:35.884 SERIAL » [ACK] (0x06) 20:35:35.884 DRIVER « [RES] [SendData] was sent: true 20:35:37.316 SERIAL « 0x01070013a500008fc1 (9 bytes) 20:35:37.317 SERIAL » [ACK] (0x06) 20:35:37.317 DRIVER « [REQ] [SendData] callback id: 165 transmit status: OK 20:35:37.394 SERIAL « 0x010a000400170431060101d5 (12 bytes) 20:35:37.395 CNTRLR [Node 023] [+] [Multilevel Sensor] supportedScales[1]: [Endpoint 0] [internal] 0 20:35:37.395 SERIAL » [ACK] (0x06) 20:35:37.396 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedScaleReport] sensor type: Air temperature supported scales: · Celsius 20:35:37.398 SERIAL » 0x010a0013180331030125a64d (12 bytes) 20:35:37.399 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 166 └─[MultilevelSensorCCGetSupportedScale] sensor type: Air temperature 20:35:37.399 CNTRLR « [Node 023] received supported scales: · Celsius 20:35:37.399 CNTRLR » [Node 023] querying Air temperature sensor reading... 20:35:37.400 SERIAL « [ACK] (0x06) 20:35:37.404 SERIAL « 0x0104011301e8 (6 bytes) 20:35:37.404 SERIAL » [ACK] (0x06) 20:35:37.405 DRIVER « [RES] [SendData] was sent: true 20:35:37.601 SERIAL « 0x0109000400110380035a39 (11 bytes) 20:35:37.603 CNTRLR [Node 017] [~] [Battery] level: 90 => 90 [Endpoint 0] 20:35:37.603 CNTRLR [Node 017] [~] [Battery] isLow: false => false [Endpoint 0] 20:35:37.604 SERIAL » [ACK] (0x06) 20:35:37.605 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 90 is low: false 20:35:38.000 SERIAL « 0x010c000400110643030142076c88 (14 bytes) 20:35:38.001 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpoint[1]: 19 => 19 [Endpoint 0] 20:35:38.002 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 20:35:38.002 SERIAL » [ACK] (0x06) 20:35:38.003 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 20:35:38.055 SERIAL « 0x010a00040011044608007fd5 (12 bytes) 20:35:38.057 CNTRLR [Node 017] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 20:35:38.058 CNTRLR [Node 017] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 20:35:38.058 SERIAL » [ACK] (0x06) 20:35:38.059 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ClimateControlScheduleCCOverrideReport] override type: None override state: Unused 20:35:38.109 SERIAL « 0x01080004001102840763 (10 bytes) 20:35:38.110 SERIAL » [ACK] (0x06) 20:35:38.111 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 20:35:38.112 CNTRLR « [Node 017] received wakeup notification 20:35:38.113 CNTRLR [Node 017] The node is now awake. 20:35:48.114 DRIVER The awake timeout for node 17 has elapsed. Assuming it is asleep. 20:35:48.115 CNTRLR [Node 017] The node is now asleep. 20:35:48.944 SERIAL « 0x010c0004001c063105042202a15c (14 bytes) 20:35:48.945 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:35:48.946 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 56.9 => 67.3 [Endpoint 0] 20:35:48.946 SERIAL » [ACK] (0x06) 20:35:48.947 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 67.3 20:35:48.994 SERIAL « 0x01070013a6000487ce (9 bytes) 20:35:48.994 SERIAL » [ACK] (0x06) 20:35:48.995 DRIVER « [REQ] [SendData] callback id: 166 transmit status: OK 20:35:49.072 SERIAL « 0x010a000400180431060101da (12 bytes) 20:35:49.073 CNTRLR [Node 024] [+] [Multilevel Sensor] supportedScales[1]: [Endpoint 0] [internal] 0 20:35:49.074 SERIAL » [ACK] (0x06) 20:35:49.074 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedScaleReport] sensor type: Air temperature supported scales: · Celsius 20:35:49.077 SERIAL » 0x010a00131a0370051625a71e (12 bytes) 20:35:49.077 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 167 └─[ConfigurationCCGet] parameter #: 22 20:35:49.078 CNTRLR « [Node 024] received supported scales: · Celsius 20:35:49.078 CNTRLR » [Node 024] querying Air temperature sensor reading... 20:35:49.080 SERIAL « [ACK] (0x06) 20:35:49.084 SERIAL « 0x0104011301e8 (6 bytes) 20:35:49.084 SERIAL » [ACK] (0x06) 20:35:49.084 DRIVER « [RES] [SendData] was sent: true 20:35:49.190 SERIAL « 0x01070013a700000b47 (9 bytes) 20:35:49.190 SERIAL » [ACK] (0x06) 20:35:49.191 DRIVER « [REQ] [SendData] callback id: 167 transmit status: OK 20:35:49.261 SERIAL « 0x010c0004001a067006160201f47c (14 bytes) 20:35:49.263 CNTRLR [Node 026] [+] [Configuration] 22: 500 20:35:49.264 SERIAL » [ACK] (0x06) 20:35:49.265 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 500 20:35:49.273 SERIAL » 0x010a00131c0370051625a817 (12 bytes) 20:35:49.274 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 168 └─[ConfigurationCCGet] parameter #: 22 20:35:49.274 CNTRLR « [Node 026] parameter #22 has value: 500 20:35:49.274 CNTRLR » [Node 026] querying parameter #23 value... 20:35:49.277 SERIAL « [ACK] (0x06) 20:35:49.279 SERIAL « 0x0104011301e8 (6 bytes) 20:35:49.279 SERIAL » [ACK] (0x06) 20:35:49.279 DRIVER « [RES] [SendData] was sent: true 20:35:49.344 SERIAL « 0x01070013a800000744 (9 bytes) 20:35:49.345 SERIAL » [ACK] (0x06) 20:35:49.345 DRIVER « [REQ] [SendData] callback id: 168 transmit status: OK 20:35:49.354 SERIAL « 0x010c0004001c067006160201f47a (14 bytes) 20:35:49.360 CNTRLR [Node 028] [+] [Configuration] 22: 500 20:35:49.361 SERIAL » [ACK] (0x06) 20:35:49.361 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 500 20:35:49.365 SERIAL » 0x010a0013030370051e25a901 (12 bytes) 20:35:49.365 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 169 └─[ConfigurationCCGet] parameter #: 30 20:35:49.365 CNTRLR « [Node 028] parameter #22 has value: 500 20:35:49.366 CNTRLR » [Node 028] querying parameter #23 value... 20:35:49.370 SERIAL « [ACK] (0x06) 20:35:49.372 SERIAL « 0x0104011301e8 (6 bytes) 20:35:49.372 SERIAL » [ACK] (0x06) 20:35:49.372 DRIVER « [RES] [SendData] was sent: true 20:35:49.390 SERIAL « 0x01070013a900000341 (9 bytes) 20:35:49.390 SERIAL » [ACK] (0x06) 20:35:49.391 DRIVER « [REQ] [SendData] callback id: 169 transmit status: OK 20:35:49.403 SERIAL « 0x010b000400030570061e013fa0 (13 bytes) 20:35:49.404 CNTRLR [Node 003] [+] [Configuration] 30: 63 20:35:49.405 SERIAL » [ACK] (0x06) 20:35:49.406 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 63 20:35:49.409 SERIAL » 0x010a0013050332017025aa2c (12 bytes) 20:35:49.410 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 170 └─[MeterCCGet] rate type: Consumed duration: Power Factor 20:35:49.410 CNTRLR « [Node 003] parameter #30 has value: 63 20:35:49.410 CNTRLR » [Node 003] querying parameter #31 value... 20:35:49.416 SERIAL « [ACK] (0x06) 20:35:49.417 SERIAL « 0x0104011301e8 (6 bytes) 20:35:49.417 SERIAL » [ACK] (0x06) 20:35:49.418 DRIVER « [RES] [SendData] was sent: true 20:35:49.430 SERIAL « 0x01070013aa00000243 (9 bytes) 20:35:49.431 SERIAL » [ACK] (0x06) 20:35:49.431 DRIVER « [REQ] [SendData] callback id: 170 transmit status: OK 20:35:49.440 SERIAL « 0x010d00040005073202a1511c000028 (15 bytes) 20:35:49.441 CNTRLR [Node 005] [Meter] value[67073]: metadata updated [Endpoint 0] 20:35:49.442 CNTRLR [Node 005] [Meter] previousValue[67073]: metadata updated [Endpoint 0] 20:35:49.442 CNTRLR [Node 005] [Meter] deltaTime[67073]: metadata updated [Endpoint 0] 20:35:49.443 CNTRLR [Node 005] [+] [Meter] value[67073]: 0.28 [Endpoint 0] 20:35:49.443 CNTRLR [Node 005] [+] [Meter] deltaTime[67073]: 0 [Endpoint 0] 20:35:49.443 SERIAL » [ACK] (0x06) 20:35:49.444 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: Power Factor rate type: Consumed value: 0.28 time delta: 0 seconds 20:35:49.448 SERIAL » 0x010a0013060332017025ab2e (12 bytes) 20:35:49.448 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 171 └─[MeterCCGet] rate type: Consumed duration: Power Factor 20:35:49.448 CNTRLR » [Node 005] querying meter value (type = Electric, scale = kVar, rate type = Co nsumed)... 20:35:49.451 SERIAL « [ACK] (0x06) 20:35:49.453 SERIAL « 0x0104011301e8 (6 bytes) 20:35:49.453 SERIAL » [ACK] (0x06) 20:35:49.454 DRIVER « [RES] [SendData] was sent: true 20:35:49.468 SERIAL « 0x01070013ab00000141 (9 bytes) 20:35:49.468 SERIAL » [ACK] (0x06) 20:35:49.469 DRIVER « [REQ] [SendData] callback id: 171 transmit status: OK 20:35:49.479 SERIAL « 0x010d00040006073202a1511a00002d (15 bytes) 20:35:49.479 CNTRLR [Node 006] [Meter] value[67073]: metadata updated [Endpoint 0] 20:35:49.480 CNTRLR [Node 006] [Meter] previousValue[67073]: metadata updated [Endpoint 0] 20:35:49.480 CNTRLR [Node 006] [Meter] deltaTime[67073]: metadata updated [Endpoint 0] 20:35:49.481 CNTRLR [Node 006] [+] [Meter] value[67073]: 0.26 [Endpoint 0] 20:35:49.481 CNTRLR [Node 006] [+] [Meter] deltaTime[67073]: 0 [Endpoint 0] 20:35:49.481 SERIAL » [ACK] (0x06) 20:35:49.482 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: Power Factor rate type: Consumed value: 0.26 time delta: 0 seconds 20:35:49.484 SERIAL » 0x010900130202750225ac1b (11 bytes) 20:35:49.485 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 172 └─[ProtectionCCGet] 20:35:49.485 CNTRLR » [Node 006] querying meter value (type = Electric, scale = kVar, rate type = Co nsumed)... 20:35:49.488 SERIAL « [ACK] (0x06) 20:35:49.490 SERIAL « 0x0104011301e8 (6 bytes) 20:35:49.490 SERIAL » [ACK] (0x06) 20:35:49.491 DRIVER « [RES] [SendData] was sent: true 20:35:49.510 SERIAL « 0x01070013ac00000245 (9 bytes) 20:35:49.510 SERIAL » [ACK] (0x06) 20:35:49.511 DRIVER « [REQ] [SendData] callback id: 172 transmit status: OK 20:35:49.534 SERIAL « 0x010a00040002047503000081 (12 bytes) 20:35:49.534 CNTRLR [Node 002] [+] [Protection] local: 0 [Endpoint 0] 20:35:49.535 CNTRLR [Node 002] [+] [Protection] rf: 0 [Endpoint 0] 20:35:49.536 SERIAL » [ACK] (0x06) 20:35:49.537 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 20:35:49.539 SERIAL » 0x010a0013130370051725ad1c (12 bytes) 20:35:49.539 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 173 └─[ConfigurationCCGet] parameter #: 23 20:35:49.539 CNTRLR « [Node 002] received protection status: local: Unprotected rf Unprotected 20:35:49.540 CNTRLR » [Node 002] querying protection timeout... 20:35:49.544 SERIAL « [ACK] (0x06) 20:35:49.545 SERIAL « 0x0104011301e8 (6 bytes) 20:35:49.545 SERIAL » [ACK] (0x06) 20:35:49.546 DRIVER « [RES] [SendData] was sent: true 20:35:49.686 SERIAL « 0x01070013ad00000e48 (9 bytes) 20:35:49.686 SERIAL » [ACK] (0x06) 20:35:49.687 DRIVER « [REQ] [SendData] callback id: 173 transmit status: OK 20:35:49.816 SERIAL « 0x010b0004001305700617010680 (13 bytes) 20:35:49.818 CNTRLR [Node 019] [+] [Configuration] 23: 6 20:35:49.819 SERIAL » [ACK] (0x06) 20:35:49.820 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 23 value size: 1 value: 6 20:35:49.825 SERIAL » 0x010a0013120332016025ae2f (12 bytes) 20:35:49.825 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 174 └─[MeterCCGet] rate type: Consumed duration: V 20:35:49.825 CNTRLR « [Node 019] parameter #23 has value: 6 20:35:49.826 CNTRLR » [Node 019] querying parameter #24 value... 20:35:49.829 SERIAL « [ACK] (0x06) 20:35:49.831 SERIAL « 0x0104011301e8 (6 bytes) 20:35:49.831 SERIAL » [ACK] (0x06) 20:35:49.833 DRIVER « [RES] [SendData] was sent: true 20:35:49.944 SERIAL « 0x01070013ae00000c49 (9 bytes) 20:35:49.944 SERIAL » [ACK] (0x06) 20:35:49.945 DRIVER « [REQ] [SendData] callback id: 174 transmit status: OK 20:35:49.954 SERIAL « 0x010e00040012083202a122092800007d (16 bytes) 20:35:49.955 CNTRLR [Node 018] [Meter] value[66561]: metadata updated [Endpoint 0] 20:35:49.956 CNTRLR [Node 018] [Meter] previousValue[66561]: metadata updated [Endpoint 0] 20:35:49.957 CNTRLR [Node 018] [Meter] deltaTime[66561]: metadata updated [Endpoint 0] 20:35:49.957 CNTRLR [Node 018] [+] [Meter] value[66561]: 234.4 [Endpoint 0] 20:35:49.958 CNTRLR [Node 018] [+] [Meter] deltaTime[66561]: 0 [Endpoint 0] 20:35:49.958 SERIAL » [ACK] (0x06) 20:35:49.959 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: V rate type: Consumed value: 234.4 time delta: 0 seconds 20:35:49.962 SERIAL » 0x010a0013140370050825af06 (12 bytes) 20:35:49.962 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 175 └─[ConfigurationCCGet] parameter #: 8 20:35:49.963 CNTRLR » [Node 018] querying meter value (type = Electric, scale = A, rate type = Consu med)... 20:35:49.966 SERIAL « [ACK] (0x06) 20:35:49.967 SERIAL « 0x0104011301e8 (6 bytes) 20:35:49.968 SERIAL » [ACK] (0x06) 20:35:49.969 DRIVER « [RES] [SendData] was sent: true 20:35:49.987 SERIAL « 0x01070013af00000246 (9 bytes) 20:35:49.988 SERIAL » [ACK] (0x06) 20:35:49.989 DRIVER « [REQ] [SendData] callback id: 175 transmit status: OK 20:35:50.012 SERIAL « 0x010c000400140670060802000099 (14 bytes) 20:35:50.013 CNTRLR [Node 020] [+] [Configuration] 8: 0 20:35:50.014 SERIAL » [ACK] (0x06) 20:35:50.015 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 2 value: 0 20:35:50.019 SERIAL » 0x010b001315043104010025b057 (13 bytes) 20:35:50.019 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 176 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 20:35:50.020 CNTRLR « [Node 020] parameter #8 has value: 0 20:35:50.020 CNTRLR » [Node 020] querying parameter #9 value... 20:35:50.025 SERIAL « [ACK] (0x06) 20:35:50.027 SERIAL « 0x0104011301e8 (6 bytes) 20:35:50.027 SERIAL » [ACK] (0x06) 20:35:50.027 DRIVER « [RES] [SendData] was sent: true 20:35:51.427 SERIAL « 0x010c0004001c06310504220232cf (14 bytes) 20:35:51.428 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:35:51.429 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 67.3 => 56.2 [Endpoint 0] 20:35:51.429 SERIAL » [ACK] (0x06) 20:35:51.430 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 56.2 20:35:51.451 SERIAL « 0x01070013b000008fd4 (9 bytes) 20:35:51.451 SERIAL » [ACK] (0x06) 20:35:51.452 DRIVER « [REQ] [SendData] callback id: 176 transmit status: OK 20:35:51.505 SERIAL « 0x010c0004001c06310504220232cf (14 bytes) 20:35:51.506 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:35:51.506 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 56.2 => 56.2 [Endpoint 0] 20:35:51.507 SERIAL » [ACK] (0x06) 20:35:51.508 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 56.2 20:35:51.530 SERIAL « 0x010c000400150631050142066ffa (14 bytes) 20:35:51.531 CNTRLR [Node 021] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 20:35:51.532 CNTRLR [Node 021] [+] [Multilevel Sensor] Air temperature: 16.47 [Endpoint 0] 20:35:51.532 SERIAL » [ACK] (0x06) 20:35:51.533 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 16.47 20:35:51.537 SERIAL » 0x010b001316043104010025b155 (13 bytes) 20:35:51.537 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 177 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 20:35:51.537 CNTRLR « [Node 021] received current Air temperature sensor reading: 16.47 °C 20:35:51.538 CNTRLR [Node 021] [+] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true 20:35:51.549 SERIAL « [ACK] (0x06) 20:35:51.550 SERIAL « 0x0104011301e8 (6 bytes) 20:35:51.550 SERIAL » [ACK] (0x06) 20:35:51.551 DRIVER « [RES] [SendData] was sent: true 20:35:51.553 CNTRLR [Node 021] MultilevelSwitchCC: doing a complete interview... 20:35:51.553 CNTRLR [Node 021] [Multilevel Switch] Up: metadata updated [Endpoint 0] 20:35:51.557 CNTRLR [Node 021] [Multilevel Switch] Down: metadata updated [Endpoint 0] 20:35:51.557 CNTRLR » [Node 021] requesting current switch state... 20:35:51.562 SERIAL « 0x010c0004001c06310504220232cf (14 bytes) 20:35:51.562 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:35:51.562 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 56.2 => 56.2 [Endpoint 0] 20:35:51.563 SERIAL » [ACK] (0x06) 20:35:51.563 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 56.2 20:35:51.610 SERIAL « 0x010c0004001c06310504220232cf (14 bytes) 20:35:51.611 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:35:51.612 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 56.2 => 56.2 [Endpoint 0] 20:35:51.612 SERIAL » [ACK] (0x06) 20:35:51.613 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 56.2 20:35:53.305 SERIAL « 0x01070013b10000b1eb (9 bytes) 20:35:53.305 SERIAL » [ACK] (0x06) 20:35:53.306 DRIVER « [REQ] [SendData] callback id: 177 transmit status: OK 20:35:53.384 SERIAL « 0x010c0004001606310501420727b0 (14 bytes) 20:35:53.385 CNTRLR [Node 022] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 20:35:53.385 CNTRLR [Node 022] [+] [Multilevel Sensor] Air temperature: 18.31 [Endpoint 0] 20:35:53.386 SERIAL » [ACK] (0x06) 20:35:53.387 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.31 20:35:53.389 SERIAL » 0x010b001317043104010025b257 (13 bytes) 20:35:53.389 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 178 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 20:35:53.389 CNTRLR « [Node 022] received current Air temperature sensor reading: 18.31 °C 20:35:53.389 CNTRLR [Node 022] [+] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true 20:35:53.392 SERIAL « [ACK] (0x06) 20:35:53.392 CNTRLR [Node 022] MultilevelSwitchCC: doing a complete interview... 20:35:53.393 CNTRLR [Node 022] [Multilevel Switch] Up: metadata updated [Endpoint 0] 20:35:53.394 CNTRLR [Node 022] [Multilevel Switch] Down: metadata updated [Endpoint 0] 20:35:53.394 CNTRLR » [Node 022] requesting current switch state... 20:35:53.396 SERIAL « 0x0104011301e8 (6 bytes) 20:35:53.396 SERIAL » [ACK] (0x06) 20:35:53.397 DRIVER « [RES] [SendData] was sent: true 20:35:54.845 SERIAL « 0x01070013b2000091c8 (9 bytes) 20:35:54.846 SERIAL » [ACK] (0x06) 20:35:54.846 DRIVER « [REQ] [SendData] callback id: 178 transmit status: OK 20:35:54.926 SERIAL « 0x010c000400170631050142074adc (14 bytes) 20:35:54.927 CNTRLR [Node 023] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 20:35:54.928 CNTRLR [Node 023] [+] [Multilevel Sensor] Air temperature: 18.66 [Endpoint 0] 20:35:54.929 SERIAL » [ACK] (0x06) 20:35:54.930 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.66 20:35:54.931 SERIAL » 0x010b001318043104010025b359 (13 bytes) 20:35:54.931 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 179 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 20:35:54.932 CNTRLR « [Node 023] received current Air temperature sensor reading: 18.66 °C 20:35:54.932 CNTRLR [Node 023] [+] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true 20:35:54.935 SERIAL « [ACK] (0x06) 20:35:54.935 CNTRLR [Node 023] MultilevelSwitchCC: doing a complete interview... 20:35:54.936 CNTRLR [Node 023] [Multilevel Switch] Up: metadata updated [Endpoint 0] 20:35:54.936 CNTRLR [Node 023] [Multilevel Switch] Down: metadata updated [Endpoint 0] 20:35:54.936 CNTRLR » [Node 023] requesting current switch state... 20:35:54.937 SERIAL « 0x0104011301e8 (6 bytes) 20:35:54.937 SERIAL » [ACK] (0x06) 20:35:54.938 DRIVER « [RES] [SendData] was sent: true 20:35:56.476 SERIAL « 0x01070013b300009ac2 (9 bytes) 20:35:56.476 SERIAL » [ACK] (0x06) 20:35:56.477 DRIVER « [REQ] [SendData] callback id: 179 transmit status: OK 20:35:56.555 SERIAL « 0x010c0004001806310501420742db (14 bytes) 20:35:56.556 CNTRLR [Node 024] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 20:35:56.556 CNTRLR [Node 024] [+] [Multilevel Sensor] Air temperature: 18.58 [Endpoint 0] 20:35:56.557 SERIAL » [ACK] (0x06) 20:35:56.558 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.58 20:35:56.560 SERIAL » 0x010a00131a0370051725b40c (12 bytes) 20:35:56.560 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 180 └─[ConfigurationCCGet] parameter #: 23 20:35:56.560 CNTRLR « [Node 024] received current Air temperature sensor reading: 18.58 °C 20:35:56.560 CNTRLR [Node 024] [+] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true 20:35:56.563 SERIAL « [ACK] (0x06) 20:35:56.564 CNTRLR [Node 024] MultilevelSwitchCC: doing a complete interview... 20:35:56.565 CNTRLR [Node 024] [Multilevel Switch] Up: metadata updated [Endpoint 0] 20:35:56.565 CNTRLR [Node 024] [Multilevel Switch] Down: metadata updated [Endpoint 0] 20:35:56.565 CNTRLR » [Node 024] requesting current switch state... 20:35:56.566 SERIAL « 0x0104011301e8 (6 bytes) 20:35:56.567 SERIAL » [ACK] (0x06) 20:35:56.567 DRIVER « [RES] [SendData] was sent: true 20:35:56.672 SERIAL « 0x01070013b400000b54 (9 bytes) 20:35:56.672 SERIAL » [ACK] (0x06) 20:35:56.673 DRIVER « [REQ] [SendData] callback id: 180 transmit status: OK 20:35:56.741 SERIAL « 0x010b0004001a05700617010689 (13 bytes) 20:35:56.743 CNTRLR [Node 026] [+] [Configuration] 23: 6 20:35:56.744 SERIAL » [ACK] (0x06) 20:35:56.744 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 23 value size: 1 value: 6 20:35:56.747 SERIAL » 0x010a00131c0370051725b50b (12 bytes) 20:35:56.748 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 181 └─[ConfigurationCCGet] parameter #: 23 20:35:56.748 CNTRLR « [Node 026] parameter #23 has value: 6 20:35:56.748 CNTRLR » [Node 026] querying parameter #24 value... 20:35:56.751 SERIAL « [ACK] (0x06) 20:35:56.753 SERIAL « 0x0104011301e8 (6 bytes) 20:35:56.753 SERIAL » [ACK] (0x06) 20:35:56.754 DRIVER « [RES] [SendData] was sent: true 20:35:56.824 SERIAL « 0x01070013b500000856 (9 bytes) 20:35:56.825 SERIAL » [ACK] (0x06) 20:35:56.825 DRIVER « [REQ] [SendData] callback id: 181 transmit status: OK 20:35:56.834 SERIAL « 0x010b0004001c0570061701068f (13 bytes) 20:35:56.835 CNTRLR [Node 028] [+] [Configuration] 23: 6 20:35:56.835 SERIAL » [ACK] (0x06) 20:35:56.835 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 23 value size: 1 value: 6 20:35:56.836 SERIAL » 0x010a0013030370051f25b61f (12 bytes) 20:35:56.836 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 182 └─[ConfigurationCCGet] parameter #: 31 20:35:56.837 CNTRLR « [Node 028] parameter #23 has value: 6 20:35:56.837 CNTRLR » [Node 028] querying parameter #24 value... 20:35:56.838 SERIAL « [ACK] (0x06) 20:35:56.842 SERIAL « 0x0104011301e8 (6 bytes) 20:35:56.842 SERIAL » [ACK] (0x06) 20:35:56.842 DRIVER « [RES] [SendData] was sent: true 20:35:56.861 SERIAL « 0x01070013b60000035e (9 bytes) 20:35:56.862 SERIAL » [ACK] (0x06) 20:35:56.862 DRIVER « [REQ] [SendData] callback id: 182 transmit status: OK 20:35:56.874 SERIAL « 0x010b000400030570061f01009e (13 bytes) 20:35:56.876 CNTRLR [Node 003] [+] [Configuration] 31: 0 20:35:56.877 SERIAL » [ACK] (0x06) 20:35:56.878 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 0 20:35:56.881 SERIAL » 0x010b001305043201780025b73f (13 bytes) 20:35:56.881 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 183 └─[MeterCCGet] rate type: Consumed duration: kVar 20:35:56.882 CNTRLR « [Node 003] parameter #31 has value: 0 20:35:56.882 CNTRLR » [Node 003] querying parameter #32 value... 20:35:56.886 SERIAL « [ACK] (0x06) 20:35:56.887 SERIAL « 0x0104011301e8 (6 bytes) 20:35:56.888 SERIAL » [ACK] (0x06) 20:35:56.889 DRIVER « [RES] [SendData] was sent: true 20:35:56.902 SERIAL « 0x01070013b70000025e (9 bytes) 20:35:56.902 SERIAL » [ACK] (0x06) 20:35:56.903 DRIVER « [REQ] [SendData] callback id: 183 transmit status: OK 20:35:56.913 SERIAL « 0x0111000400050b3202a17c0000000000000009 (19 bytes) 20:35:56.914 CNTRLR [Node 005] [Meter] value[67329]: metadata updated [Endpoint 0] 20:35:56.915 CNTRLR [Node 005] [Meter] previousValue[67329]: metadata updated [Endpoint 0] 20:35:56.915 CNTRLR [Node 005] [Meter] deltaTime[67329]: metadata updated [Endpoint 0] 20:35:56.916 CNTRLR [Node 005] [+] [Meter] value[67329]: 0 [Endpoint 0] 20:35:56.919 CNTRLR [Node 005] [+] [Meter] deltaTime[67329]: 0 [Endpoint 0] 20:35:56.920 SERIAL » [ACK] (0x06) 20:35:56.921 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kVar rate type: Consumed value: 0 time delta: 0 seconds 20:35:56.924 SERIAL » 0x010b001306043201780025b833 (13 bytes) 20:35:56.924 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 184 └─[MeterCCGet] rate type: Consumed duration: kVar 20:35:56.924 CNTRLR » [Node 005] querying meter value (type = Electric, scale = kVarh, rate type = C onsumed)... 20:35:56.927 SERIAL « [ACK] (0x06) 20:35:56.930 SERIAL « 0x0104011301e8 (6 bytes) 20:35:56.930 SERIAL » [ACK] (0x06) 20:35:56.930 DRIVER « [RES] [SendData] was sent: true 20:35:56.945 SERIAL « 0x01070013b800000251 (9 bytes) 20:35:56.945 SERIAL » [ACK] (0x06) 20:35:56.945 DRIVER « [REQ] [SendData] callback id: 184 transmit status: OK 20:35:56.955 SERIAL « 0x0111000400060b3202a17c000000000000000a (19 bytes) 20:35:56.956 CNTRLR [Node 006] [Meter] value[67329]: metadata updated [Endpoint 0] 20:35:56.957 CNTRLR [Node 006] [Meter] previousValue[67329]: metadata updated [Endpoint 0] 20:35:56.957 CNTRLR [Node 006] [Meter] deltaTime[67329]: metadata updated [Endpoint 0] 20:35:56.958 CNTRLR [Node 006] [+] [Meter] value[67329]: 0 [Endpoint 0] 20:35:56.958 CNTRLR [Node 006] [+] [Meter] deltaTime[67329]: 0 [Endpoint 0] 20:35:56.959 SERIAL » [ACK] (0x06) 20:35:56.960 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kVar rate type: Consumed value: 0 time delta: 0 seconds 20:35:56.964 SERIAL » 0x010900130202750a25b906 (11 bytes) 20:35:56.964 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 185 └─[ProtectionCCTimeoutGet] 20:35:56.965 CNTRLR » [Node 006] querying meter value (type = Electric, scale = kVarh, rate type = C onsumed)... 20:35:56.969 SERIAL « [ACK] (0x06) 20:35:56.970 SERIAL « 0x0104011301e8 (6 bytes) 20:35:56.970 SERIAL » [ACK] (0x06) 20:35:56.972 DRIVER « [RES] [SendData] was sent: true 20:35:56.989 SERIAL « 0x01070013b900000250 (9 bytes) 20:35:56.990 SERIAL » [ACK] (0x06) 20:35:56.990 DRIVER « [REQ] [SendData] callback id: 185 transmit status: OK 20:35:57.013 SERIAL « 0x01090004000203750b008d (11 bytes) 20:35:57.015 CNTRLR [Node 002] [+] [Protection] timeout: [Timeout: none] [Endpoint 0] 20:35:57.016 SERIAL » [ACK] (0x06) 20:35:57.017 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[ProtectionCCTimeoutReport] timeout: [Timeout: none] 20:35:57.020 SERIAL » 0x010a0013130370051825ba04 (12 bytes) 20:35:57.021 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 186 └─[ConfigurationCCGet] parameter #: 24 20:35:57.021 CNTRLR « [Node 002] received timeout: [Timeout: none] 20:35:57.021 CNTRLR » [Node 002] querying exclusive control node... 20:35:57.025 SERIAL « [ACK] (0x06) 20:35:57.026 SERIAL « 0x0104011301e8 (6 bytes) 20:35:57.026 SERIAL » [ACK] (0x06) 20:35:57.027 DRIVER « [RES] [SendData] was sent: true 20:35:57.167 SERIAL « 0x01070013ba00000e5f (9 bytes) 20:35:57.168 SERIAL » [ACK] (0x06) 20:35:57.168 DRIVER « [REQ] [SendData] callback id: 186 transmit status: OK 20:35:57.298 SERIAL « 0x010c00040013067006180200ff71 (14 bytes) 20:35:57.300 CNTRLR [Node 019] [+] [Configuration] 24: 255 20:35:57.301 SERIAL » [ACK] (0x06) 20:35:57.302 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 24 value size: 2 value: 255 20:35:57.309 SERIAL » 0x010a0013120332016825bb32 (12 bytes) 20:35:57.310 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 187 └─[MeterCCGet] rate type: Consumed duration: A 20:35:57.310 CNTRLR « [Node 019] parameter #24 has value: 255 20:35:57.310 CNTRLR » [Node 019] querying parameter #30 value... 20:35:57.313 SERIAL « [ACK] (0x06) 20:35:57.315 SERIAL « 0x0104011301e8 (6 bytes) 20:35:57.315 SERIAL » [ACK] (0x06) 20:35:57.317 DRIVER « [RES] [SendData] was sent: true 20:35:57.424 SERIAL « 0x01070013bb00000b5b (9 bytes) 20:35:57.425 SERIAL » [ACK] (0x06) 20:35:57.425 DRIVER « [REQ] [SendData] callback id: 187 transmit status: OK 20:35:57.434 SERIAL « 0x010e00040012083202a14a0000000034 (16 bytes) 20:35:57.435 CNTRLR [Node 018] [Meter] value[66817]: metadata updated [Endpoint 0] 20:35:57.436 CNTRLR [Node 018] [Meter] previousValue[66817]: metadata updated [Endpoint 0] 20:35:57.437 CNTRLR [Node 018] [Meter] deltaTime[66817]: metadata updated [Endpoint 0] 20:35:57.437 CNTRLR [Node 018] [+] [Meter] value[66817]: 0 [Endpoint 0] 20:35:57.438 CNTRLR [Node 018] [+] [Meter] deltaTime[66817]: 0 [Endpoint 0] 20:35:57.438 SERIAL » [ACK] (0x06) 20:35:57.439 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: A rate type: Consumed value: 0 time delta: 0 seconds 20:35:57.442 SERIAL » 0x010a0013140370050925bc14 (12 bytes) 20:35:57.443 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 188 └─[ConfigurationCCGet] parameter #: 9 20:35:57.443 CNTRLR » [Node 018] querying meter value (type = Electric, scale = Power Factor, rate t ype = Consumed)... 20:35:57.446 SERIAL « [ACK] (0x06) 20:35:57.449 SERIAL « 0x0104011301e8 (6 bytes) 20:35:57.454 SERIAL » [ACK] (0x06) 20:35:57.454 DRIVER « [RES] [SendData] was sent: true 20:35:57.467 SERIAL « 0x01070013bc00000255 (9 bytes) 20:35:57.468 SERIAL » [ACK] (0x06) 20:35:57.468 DRIVER « [REQ] [SendData] callback id: 188 transmit status: OK 20:35:57.492 SERIAL « 0x010b000400140570060901009f (13 bytes) 20:35:57.493 CNTRLR [Node 020] [+] [Configuration] 9: 0 20:35:57.494 SERIAL » [ACK] (0x06) 20:35:57.495 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 1 value: 0 20:35:57.498 SERIAL » 0x010900131502260225bd4e (11 bytes) 20:35:57.498 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 189 └─[MultilevelSwitchCCGet] 20:35:57.498 CNTRLR « [Node 020] parameter #9 has value: 0 20:35:57.499 CNTRLR [Node 020] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 20:35:57.504 SERIAL « [ACK] (0x06) 20:35:57.506 SERIAL « 0x0104011301e8 (6 bytes) 20:35:57.507 SERIAL » [ACK] (0x06) 20:35:57.508 DRIVER « [RES] [SendData] was sent: true 20:35:57.510 CNTRLR [Node 020] ProtectionCC: doing a complete interview... 20:35:57.510 CNTRLR » [Node 020] querying protection capabilities... 20:35:58.925 SERIAL « 0x01070013bd00008ed8 (9 bytes) 20:35:58.925 SERIAL » [ACK] (0x06) 20:35:58.926 DRIVER « [REQ] [SendData] callback id: 189 transmit status: OK 20:35:59.000 SERIAL « 0x01090004001503260300c1 (11 bytes) 20:35:59.002 CNTRLR [Node 021] [+] [Multilevel Switch] currentValue: 0 [Endpoint 0] 20:35:59.003 SERIAL » [ACK] (0x06) 20:35:59.004 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 0 20:35:59.005 SERIAL » 0x010900131602260225be4e (11 bytes) 20:35:59.005 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 190 └─[MultilevelSwitchCCGet] 20:35:59.006 CNTRLR [Node 021] [+] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true 20:35:59.010 SERIAL « [ACK] (0x06) 20:35:59.011 SERIAL « 0x0104011301e8 (6 bytes) 20:35:59.011 SERIAL » [ACK] (0x06) 20:35:59.011 CNTRLR [Node 021] ConfigurationCC: Loading configuration parameters from device confi g 20:35:59.012 CNTRLR [Node 021] [+] [Configuration] isParamInformationFromConfig: false [internal] 20:35:59.012 CNTRLR [Node 021] [Configuration] 1: metadata updated 20:35:59.013 CNTRLR [Node 021] [Configuration] 2: metadata updated 20:35:59.013 CNTRLR [Node 021] [Configuration] 3: metadata updated 20:35:59.013 CNTRLR [Node 021] [Configuration] 4: metadata updated 20:35:59.014 CNTRLR [Node 021] [Configuration] 5: metadata updated 20:35:59.015 CNTRLR [Node 021] [Configuration] 6: metadata updated 20:35:59.016 CNTRLR [Node 021] [Configuration] 7: metadata updated 20:35:59.016 CNTRLR [Node 021] [Configuration] 8: metadata updated 20:35:59.017 CNTRLR [Node 021] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 20:35:59.017 CNTRLR » [Node 021] querying parameter #1 value... 20:35:59.018 DRIVER « [RES] [SendData] was sent: true 20:36:00.711 SERIAL « 0x01070013be0000abfe (9 bytes) 20:36:00.711 SERIAL » [ACK] (0x06) 20:36:00.712 DRIVER « [REQ] [SendData] callback id: 190 transmit status: OK 20:36:00.793 SERIAL « 0x0109000400160326031edc (11 bytes) 20:36:00.794 CNTRLR [Node 022] [+] [Multilevel Switch] currentValue: 30 [Endpoint 0] 20:36:00.795 SERIAL » [ACK] (0x06) 20:36:00.796 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 30 20:36:00.798 SERIAL » 0x010900131702260225bf4e (11 bytes) 20:36:00.798 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 191 └─[MultilevelSwitchCCGet] 20:36:00.798 CNTRLR [Node 022] [+] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true 20:36:00.800 SERIAL « [ACK] (0x06) 20:36:00.803 CNTRLR [Node 022] ConfigurationCC: Loading configuration parameters from device confi g 20:36:00.803 CNTRLR [Node 022] [+] [Configuration] isParamInformationFromConfig: false [internal] 20:36:00.803 CNTRLR [Node 022] [Configuration] 1: metadata updated 20:36:00.804 CNTRLR [Node 022] [Configuration] 2: metadata updated 20:36:00.804 CNTRLR [Node 022] [Configuration] 3: metadata updated 20:36:00.805 CNTRLR [Node 022] [Configuration] 4: metadata updated 20:36:00.805 CNTRLR [Node 022] [Configuration] 5: metadata updated 20:36:00.805 CNTRLR [Node 022] [Configuration] 6: metadata updated 20:36:00.806 CNTRLR [Node 022] [Configuration] 7: metadata updated 20:36:00.806 CNTRLR [Node 022] [Configuration] 8: metadata updated 20:36:00.806 CNTRLR [Node 022] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 20:36:00.807 CNTRLR » [Node 022] querying parameter #1 value... 20:36:00.808 SERIAL « 0x0104011301e8 (6 bytes) 20:36:00.808 SERIAL » [ACK] (0x06) 20:36:00.809 DRIVER « [RES] [SendData] was sent: true 20:36:02.235 SERIAL « 0x01070013bf00008fdb (9 bytes) 20:36:02.236 SERIAL » [ACK] (0x06) 20:36:02.236 DRIVER « [REQ] [SendData] callback id: 191 transmit status: OK 20:36:02.317 SERIAL « 0x01090004001703260312d1 (11 bytes) 20:36:02.318 CNTRLR [Node 023] [+] [Multilevel Switch] currentValue: 18 [Endpoint 0] 20:36:02.319 SERIAL » [ACK] (0x06) 20:36:02.320 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 18 20:36:02.322 SERIAL » 0x010900131802260225c03e (11 bytes) 20:36:02.323 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 192 └─[MultilevelSwitchCCGet] 20:36:02.323 CNTRLR [Node 023] [+] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true 20:36:02.325 SERIAL « [ACK] (0x06) 20:36:02.326 CNTRLR [Node 023] ConfigurationCC: Loading configuration parameters from device confi g 20:36:02.327 CNTRLR [Node 023] [+] [Configuration] isParamInformationFromConfig: false [internal] 20:36:02.327 CNTRLR [Node 023] [Configuration] 1: metadata updated 20:36:02.328 CNTRLR [Node 023] [Configuration] 2: metadata updated 20:36:02.328 CNTRLR [Node 023] [Configuration] 3: metadata updated 20:36:02.328 CNTRLR [Node 023] [Configuration] 4: metadata updated 20:36:02.329 CNTRLR [Node 023] [Configuration] 5: metadata updated 20:36:02.329 CNTRLR [Node 023] [Configuration] 6: metadata updated 20:36:02.330 CNTRLR [Node 023] [Configuration] 7: metadata updated 20:36:02.330 CNTRLR [Node 023] [Configuration] 8: metadata updated 20:36:02.331 CNTRLR [Node 023] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 20:36:02.331 CNTRLR » [Node 023] querying parameter #1 value... 20:36:02.332 SERIAL « 0x0104011301e8 (6 bytes) 20:36:02.333 SERIAL » [ACK] (0x06) 20:36:02.333 DRIVER « [RES] [SendData] was sent: true 20:36:03.844 SERIAL « 0x01070013c0000098b3 (9 bytes) 20:36:03.845 SERIAL » [ACK] (0x06) 20:36:03.845 DRIVER « [REQ] [SendData] callback id: 192 transmit status: OK 20:36:03.925 SERIAL « 0x0109000400180326031ad6 (11 bytes) 20:36:03.926 CNTRLR [Node 024] [+] [Multilevel Switch] currentValue: 26 [Endpoint 0] 20:36:03.926 SERIAL » [ACK] (0x06) 20:36:03.929 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 26 20:36:03.931 SERIAL » 0x010a00131a0370051825c176 (12 bytes) 20:36:03.931 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 193 └─[ConfigurationCCGet] parameter #: 24 20:36:03.931 CNTRLR [Node 024] [+] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true 20:36:03.933 SERIAL « [ACK] (0x06) 20:36:03.934 CNTRLR [Node 024] ConfigurationCC: Loading configuration parameters from device confi g 20:36:03.935 CNTRLR [Node 024] [+] [Configuration] isParamInformationFromConfig: false [internal] 20:36:03.935 CNTRLR [Node 024] [Configuration] 1: metadata updated 20:36:03.935 CNTRLR [Node 024] [Configuration] 2: metadata updated 20:36:03.936 CNTRLR [Node 024] [Configuration] 3: metadata updated 20:36:03.936 CNTRLR [Node 024] [Configuration] 4: metadata updated 20:36:03.936 CNTRLR [Node 024] [Configuration] 5: metadata updated 20:36:03.937 CNTRLR [Node 024] [Configuration] 6: metadata updated 20:36:03.937 CNTRLR [Node 024] [Configuration] 7: metadata updated 20:36:03.937 CNTRLR [Node 024] [Configuration] 8: metadata updated 20:36:03.938 CNTRLR [Node 024] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 20:36:03.938 CNTRLR » [Node 024] querying parameter #1 value... 20:36:03.940 SERIAL « 0x0104011301e8 (6 bytes) 20:36:03.940 SERIAL » [ACK] (0x06) 20:36:03.940 DRIVER « [RES] [SendData] was sent: true 20:36:04.040 SERIAL « 0x01070013c100000b21 (9 bytes) 20:36:04.040 SERIAL » [ACK] (0x06) 20:36:04.041 DRIVER « [REQ] [SendData] callback id: 193 transmit status: OK 20:36:04.101 SERIAL « 0x010c0004001a067006180200ff78 (14 bytes) 20:36:04.103 CNTRLR [Node 026] [+] [Configuration] 24: 255 20:36:04.104 SERIAL » [ACK] (0x06) 20:36:04.106 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 24 value size: 2 value: 255 20:36:04.109 SERIAL » 0x010a00131c0370051825c273 (12 bytes) 20:36:04.109 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 194 └─[ConfigurationCCGet] parameter #: 24 20:36:04.110 CNTRLR « [Node 026] parameter #24 has value: 255 20:36:04.110 CNTRLR » [Node 026] querying parameter #30 value... 20:36:04.113 SERIAL « [ACK] (0x06) 20:36:04.115 SERIAL « 0x0104011301e8 (6 bytes) 20:36:04.115 SERIAL » [ACK] (0x06) 20:36:04.116 DRIVER « [RES] [SendData] was sent: true 20:36:04.184 SERIAL « 0x01070013c20000072e (9 bytes) 20:36:04.185 SERIAL » [ACK] (0x06) 20:36:04.185 DRIVER « [REQ] [SendData] callback id: 194 transmit status: OK 20:36:04.194 SERIAL « 0x010c0004001c067006180200ff7e (14 bytes) 20:36:04.196 CNTRLR [Node 028] [+] [Configuration] 24: 255 20:36:04.197 SERIAL » [ACK] (0x06) 20:36:04.198 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 24 value size: 2 value: 255 20:36:04.203 SERIAL » 0x010a0013030370052025c355 (12 bytes) 20:36:04.203 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 195 └─[ConfigurationCCGet] parameter #: 32 20:36:04.204 CNTRLR « [Node 028] parameter #24 has value: 255 20:36:04.204 CNTRLR » [Node 028] querying parameter #30 value... 20:36:04.207 SERIAL « [ACK] (0x06) 20:36:04.209 SERIAL « 0x0104011301e8 (6 bytes) 20:36:04.209 SERIAL » [ACK] (0x06) 20:36:04.210 DRIVER « [RES] [SendData] was sent: true 20:36:04.228 SERIAL « 0x01070013c30000022a (9 bytes) 20:36:04.229 SERIAL » [ACK] (0x06) 20:36:04.229 DRIVER « [REQ] [SendData] callback id: 195 transmit status: OK 20:36:04.241 SERIAL « 0x010c0004000306700620020258fc (14 bytes) 20:36:04.243 CNTRLR [Node 003] [+] [Configuration] 32: 600 20:36:04.244 SERIAL » [ACK] (0x06) 20:36:04.245 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 2 value: 600 20:36:04.249 SERIAL » 0x010b001305043201780125c44d (13 bytes) 20:36:04.250 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 196 └─[MeterCCGet] rate type: Consumed duration: kVarh 20:36:04.250 CNTRLR « [Node 003] parameter #32 has value: 600 20:36:04.250 CNTRLR » [Node 003] querying parameter #40 value... 20:36:04.254 SERIAL « [ACK] (0x06) 20:36:04.256 SERIAL « 0x0104011301e8 (6 bytes) 20:36:04.256 SERIAL » [ACK] (0x06) 20:36:04.258 DRIVER « [RES] [SendData] was sent: true 20:36:04.271 SERIAL « 0x01070013c40000022d (9 bytes) 20:36:04.271 SERIAL » [ACK] (0x06) 20:36:04.272 DRIVER « [REQ] [SendData] callback id: 196 transmit status: OK 20:36:04.282 SERIAL « 0x0115000400050f3202a15c0000000001c50000000001ec (23 bytes) 20:36:04.283 CNTRLR [Node 005] [Meter] value[67585]: metadata updated [Endpoint 0] 20:36:04.283 CNTRLR [Node 005] [Meter] previousValue[67585]: metadata updated [Endpoint 0] 20:36:04.284 CNTRLR [Node 005] [Meter] deltaTime[67585]: metadata updated [Endpoint 0] 20:36:04.284 CNTRLR [Node 005] [+] [Meter] value[67585]: 0 [Endpoint 0] 20:36:04.285 CNTRLR [Node 005] [+] [Meter] previousValue[67585]: 0 [Endpoint 0] 20:36:04.285 CNTRLR [Node 005] [+] [Meter] deltaTime[67585]: 453 [Endpoint 0] 20:36:04.286 SERIAL » [ACK] (0x06) 20:36:04.287 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kVarh rate type: Consumed value: 0 time delta: 453 seconds prev. value: 0 20:36:04.290 SERIAL » 0x010b001306043201780125c54f (13 bytes) 20:36:04.290 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 197 └─[MeterCCGet] rate type: Consumed duration: kVarh 20:36:04.291 CNTRLR [Node 005] [+] [Meter] interviewComplete: true [Endpoint 0] [internal] 20:36:04.298 SERIAL « [ACK] (0x06) 20:36:04.299 SERIAL « 0x0104011301e8 (6 bytes) 20:36:04.299 SERIAL » [ACK] (0x06) 20:36:04.300 DRIVER « [RES] [SendData] was sent: true 20:36:04.301 CNTRLR [Node 005] ProtectionCC: doing a complete interview... 20:36:04.301 CNTRLR » [Node 005] querying protection capabilities... 20:36:04.311 SERIAL « 0x01070013c50000022c (9 bytes) 20:36:04.311 SERIAL » [ACK] (0x06) 20:36:04.311 DRIVER « [REQ] [SendData] callback id: 197 transmit status: OK 20:36:04.324 SERIAL « 0x0115000400060f3202a15c0000000001c60000000001ec (23 bytes) 20:36:04.324 CNTRLR [Node 006] [Meter] value[67585]: metadata updated [Endpoint 0] 20:36:04.325 CNTRLR [Node 006] [Meter] previousValue[67585]: metadata updated [Endpoint 0] 20:36:04.325 CNTRLR [Node 006] [Meter] deltaTime[67585]: metadata updated [Endpoint 0] 20:36:04.325 CNTRLR [Node 006] [+] [Meter] value[67585]: 0 [Endpoint 0] 20:36:04.326 CNTRLR [Node 006] [+] [Meter] previousValue[67585]: 0 [Endpoint 0] 20:36:04.326 CNTRLR [Node 006] [+] [Meter] deltaTime[67585]: 454 [Endpoint 0] 20:36:04.326 SERIAL » [ACK] (0x06) 20:36:04.327 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kVarh rate type: Consumed value: 0 time delta: 454 seconds prev. value: 0 20:36:04.329 SERIAL » 0x010900130202750725c674 (11 bytes) 20:36:04.329 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 198 └─[ProtectionCCExclusiveControlGet] 20:36:04.329 CNTRLR [Node 006] [+] [Meter] interviewComplete: true [Endpoint 0] [internal] 20:36:04.330 CNTRLR [Node 006] ProtectionCC: doing a complete interview... 20:36:04.330 CNTRLR » [Node 006] querying protection capabilities... 20:36:04.332 SERIAL « [ACK] (0x06) 20:36:04.334 SERIAL « 0x0104011301e8 (6 bytes) 20:36:04.334 SERIAL » [ACK] (0x06) 20:36:04.335 DRIVER « [RES] [SendData] was sent: true 20:36:04.354 SERIAL « 0x01070013c60000022f (9 bytes) 20:36:04.354 SERIAL » [ACK] (0x06) 20:36:04.355 DRIVER « [REQ] [SendData] callback id: 198 transmit status: OK 20:36:04.378 SERIAL « 0x010900040002037508008e (11 bytes) 20:36:04.379 CNTRLR [Node 002] [+] [Protection] exclusiveControlNodeId: 0 [Endpoint 0] 20:36:04.379 SERIAL » [ACK] (0x06) 20:36:04.381 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[ProtectionCCExclusiveControlReport] exclusive control node id: 0 20:36:04.383 SERIAL » 0x010a0013130370051e25c77f (12 bytes) 20:36:04.384 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 199 └─[ConfigurationCCGet] parameter #: 30 20:36:04.384 CNTRLR « [Node 002] no node has exclusive control 20:36:04.384 CNTRLR [Node 002] [+] [Protection] interviewComplete: true [Endpoint 0] [internal] 20:36:04.386 CNTRLR [Node 002] AssociationCC: doing a complete interview... 20:36:04.386 CNTRLR » [Node 002] querying number of association groups... 20:36:04.397 SERIAL « [ACK] (0x06) 20:36:04.398 SERIAL « 0x0104011301e8 (6 bytes) 20:36:04.398 SERIAL » [ACK] (0x06) 20:36:04.400 DRIVER « [RES] [SendData] was sent: true 20:36:04.531 SERIAL « 0x01070013c700000f23 (9 bytes) 20:36:04.531 SERIAL » [ACK] (0x06) 20:36:04.532 DRIVER « [REQ] [SendData] callback id: 199 transmit status: OK 20:36:04.657 SERIAL « 0x010b000400130570061e013fb0 (13 bytes) 20:36:04.662 CNTRLR [Node 019] [+] [Configuration] 30: 63 20:36:04.663 SERIAL » [ACK] (0x06) 20:36:04.664 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 63 20:36:04.671 SERIAL » 0x010a0013120332017025c859 (12 bytes) 20:36:04.678 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 200 └─[MeterCCGet] rate type: Consumed duration: Power Factor 20:36:04.678 CNTRLR « [Node 019] parameter #30 has value: 63 20:36:04.678 CNTRLR » [Node 019] querying parameter #31 value... 20:36:04.684 SERIAL « [ACK] (0x06) 20:36:04.685 SERIAL « 0x0104011301e8 (6 bytes) 20:36:04.686 SERIAL » [ACK] (0x06) 20:36:04.689 DRIVER « [RES] [SendData] was sent: true 20:36:04.765 SERIAL « 0x01070013c80000082b (9 bytes) 20:36:04.765 SERIAL » [ACK] (0x06) 20:36:04.765 DRIVER « [REQ] [SendData] callback id: 200 transmit status: OK 20:36:04.775 SERIAL « 0x010d00040012073202a1511c00003f (15 bytes) 20:36:04.776 CNTRLR [Node 018] [Meter] value[67073]: metadata updated [Endpoint 0] 20:36:04.777 CNTRLR [Node 018] [Meter] previousValue[67073]: metadata updated [Endpoint 0] 20:36:04.777 CNTRLR [Node 018] [Meter] deltaTime[67073]: metadata updated [Endpoint 0] 20:36:04.778 CNTRLR [Node 018] [+] [Meter] value[67073]: 0.28 [Endpoint 0] 20:36:04.779 CNTRLR [Node 018] [+] [Meter] deltaTime[67073]: 0 [Endpoint 0] 20:36:04.779 SERIAL » [ACK] (0x06) 20:36:04.780 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: Power Factor rate type: Consumed value: 0.28 time delta: 0 seconds 20:36:04.783 SERIAL » 0x010900131402750425c96e (11 bytes) 20:36:04.784 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 201 └─[ProtectionCCSupportedGet] 20:36:04.784 CNTRLR » [Node 018] querying meter value (type = Electric, scale = kVar, rate type = Co nsumed)... 20:36:04.787 SERIAL « [ACK] (0x06) 20:36:04.790 SERIAL « 0x0104011301e8 (6 bytes) 20:36:04.790 SERIAL » [ACK] (0x06) 20:36:04.790 DRIVER « [RES] [SendData] was sent: true 20:36:04.808 SERIAL « 0x01070013c900000220 (9 bytes) 20:36:04.809 SERIAL » [ACK] (0x06) 20:36:04.809 DRIVER « [REQ] [SendData] callback id: 201 transmit status: OK 20:36:04.853 SERIAL « 0x010d00040014077505030700070096 (15 bytes) 20:36:04.854 CNTRLR [Node 020] [+] [Protection] supportsExclusiveControl: [Endpoint 0] [internal] true 20:36:04.855 CNTRLR [Node 020] [+] [Protection] supportsTimeout: true [Endpoint 0] [internal] 20:36:04.855 CNTRLR [Node 020] [+] [Protection] supportedLocalStates: 0,1, [Endpoint 0] [internal] 2 20:36:04.855 CNTRLR [Node 020] [+] [Protection] supportedRFStates: 0,1,2 [Endpoint 0] [internal] 20:36:04.856 CNTRLR [Node 020] [Protection] local: metadata updated [Endpoint 0] 20:36:04.857 CNTRLR [Node 020] [Protection] rf: metadata updated [Endpoint 0] 20:36:04.857 SERIAL » [ACK] (0x06) 20:36:04.858 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[ProtectionCCSupportedReport] supports exclusive control: true supports timeout: true local protection states: · Unprotected · ProtectedBySequence · NoOperationPossible RF protection states: · Unprotected · NoControl · NoResponse 20:36:04.861 SERIAL » 0x010a0013150370050125ca6b (12 bytes) 20:36:04.861 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 202 └─[ConfigurationCCGet] parameter #: 1 20:36:04.861 CNTRLR « [Node 020] received protection capabilities: exclusive control: true timeout: true local protection states: · Unprotected · ProtectedBySequence · NoOperationPossible RF protection states: · Unprotected · NoControl · NoResponse 20:36:04.862 CNTRLR » [Node 020] querying protection status... 20:36:04.865 SERIAL « [ACK] (0x06) 20:36:04.868 SERIAL « 0x0104011301e8 (6 bytes) 20:36:04.868 SERIAL » [ACK] (0x06) 20:36:04.869 DRIVER « [RES] [SendData] was sent: true 20:36:06.268 SERIAL « 0x01070013ca00008cad (9 bytes) 20:36:06.268 SERIAL » [ACK] (0x06) 20:36:06.269 DRIVER « [REQ] [SendData] callback id: 202 transmit status: OK 20:36:06.352 SERIAL « 0x010b0004001505700601010197 (13 bytes) 20:36:06.354 CNTRLR [Node 021] [+] [Configuration] 1: 1 20:36:06.355 SERIAL » [ACK] (0x06) 20:36:06.356 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 1 20:36:06.359 SERIAL » 0x010a0013160370050125cb69 (12 bytes) 20:36:06.359 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 203 └─[ConfigurationCCGet] parameter #: 1 20:36:06.359 CNTRLR « [Node 021] parameter #1 has value: 1 20:36:06.359 CNTRLR » [Node 021] querying parameter #2 value... 20:36:06.363 SERIAL « [ACK] (0x06) 20:36:06.366 SERIAL « 0x0104011301e8 (6 bytes) 20:36:06.366 SERIAL » [ACK] (0x06) 20:36:06.367 DRIVER « [RES] [SendData] was sent: true 20:36:08.002 SERIAL « 0x01070013cb0000a484 (9 bytes) 20:36:08.002 SERIAL » [ACK] (0x06) 20:36:08.002 DRIVER « [REQ] [SendData] callback id: 203 transmit status: OK 20:36:08.087 SERIAL « 0x010b0004001605700601010095 (13 bytes) 20:36:08.089 CNTRLR [Node 022] [+] [Configuration] 1: 0 20:36:08.090 SERIAL » [ACK] (0x06) 20:36:08.091 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 0 20:36:08.092 SERIAL » 0x010a0013170370050125cc6f (12 bytes) 20:36:08.092 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 204 └─[ConfigurationCCGet] parameter #: 1 20:36:08.093 CNTRLR « [Node 022] parameter #1 has value: 0 20:36:08.093 CNTRLR » [Node 022] querying parameter #2 value... 20:36:08.095 SERIAL « [ACK] (0x06) 20:36:08.097 SERIAL « 0x0104011301e8 (6 bytes) 20:36:08.098 SERIAL » [ACK] (0x06) 20:36:08.098 DRIVER « [RES] [SendData] was sent: true 20:36:09.526 SERIAL « 0x01070013cc00008fa8 (9 bytes) 20:36:09.526 SERIAL » [ACK] (0x06) 20:36:09.527 DRIVER « [REQ] [SendData] callback id: 204 transmit status: OK 20:36:09.609 SERIAL « 0x010b0004001705700601010094 (13 bytes) 20:36:09.612 CNTRLR [Node 023] [+] [Configuration] 1: 0 20:36:09.612 SERIAL » [ACK] (0x06) 20:36:09.613 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 0 20:36:09.616 SERIAL » 0x010a0013180370050125cd61 (12 bytes) 20:36:09.617 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 205 └─[ConfigurationCCGet] parameter #: 1 20:36:09.617 CNTRLR « [Node 023] parameter #1 has value: 0 20:36:09.617 CNTRLR » [Node 023] querying parameter #2 value... 20:36:09.620 SERIAL « [ACK] (0x06) 20:36:09.622 SERIAL « 0x0104011301e8 (6 bytes) 20:36:09.622 SERIAL » [ACK] (0x06) 20:36:09.623 DRIVER « [RES] [SendData] was sent: true 20:36:09.810 SERIAL « 0x010c0004001c063105042202a75a (14 bytes) 20:36:09.811 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:36:09.812 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 56.2 => 67.9 [Endpoint 0] 20:36:09.812 SERIAL » [ACK] (0x06) 20:36:09.813 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 67.9 20:36:11.360 SERIAL « 0x010c0004001c0631050422023bc6 (14 bytes) 20:36:11.361 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:36:11.362 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 67.9 => 57.1 [Endpoint 0] 20:36:11.362 SERIAL » [ACK] (0x06) 20:36:11.363 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 57.1 20:36:11.392 SERIAL « 0x010c0004001c0631050422023bc6 (14 bytes) 20:36:11.393 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:36:11.393 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 57.1 => 57.1 [Endpoint 0] 20:36:11.393 SERIAL » [ACK] (0x06) 20:36:11.394 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 57.1 20:36:11.420 SERIAL « 0x01070013cd0000b492 (9 bytes) 20:36:11.420 SERIAL » [ACK] (0x06) 20:36:11.421 DRIVER « [REQ] [SendData] callback id: 205 transmit status: OK 20:36:11.472 SERIAL « 0x010b000400180570060101009b (13 bytes) 20:36:11.473 CNTRLR [Node 024] [+] [Configuration] 1: 0 20:36:11.474 SERIAL » [ACK] (0x06) 20:36:11.474 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 0 20:36:11.475 SERIAL » 0x010a00131a0370051e25ce7f (12 bytes) 20:36:11.475 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 206 └─[ConfigurationCCGet] parameter #: 30 20:36:11.476 CNTRLR « [Node 024] parameter #1 has value: 0 20:36:11.476 CNTRLR » [Node 024] querying parameter #2 value... 20:36:11.477 SERIAL « [ACK] (0x06) 20:36:11.481 SERIAL « 0x0104011301e8 (6 bytes) 20:36:11.481 SERIAL » [ACK] (0x06) 20:36:11.481 DRIVER « [RES] [SendData] was sent: true 20:36:11.589 SERIAL « 0x01070013ce00000b2e (9 bytes) 20:36:11.589 SERIAL » [ACK] (0x06) 20:36:11.590 DRIVER « [REQ] [SendData] callback id: 206 transmit status: OK 20:36:11.661 SERIAL « 0x010b0004001a0570061e013fb9 (13 bytes) 20:36:11.663 CNTRLR [Node 026] [+] [Configuration] 30: 63 20:36:11.664 SERIAL » [ACK] (0x06) 20:36:11.664 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 63 20:36:11.667 SERIAL » 0x010a00131c0370051e25cf78 (12 bytes) 20:36:11.667 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 207 └─[ConfigurationCCGet] parameter #: 30 20:36:11.668 CNTRLR « [Node 026] parameter #30 has value: 63 20:36:11.668 CNTRLR » [Node 026] querying parameter #31 value... 20:36:11.671 SERIAL « [ACK] (0x06) 20:36:11.673 SERIAL « 0x0104011301e8 (6 bytes) 20:36:11.673 SERIAL » [ACK] (0x06) 20:36:11.674 DRIVER « [RES] [SendData] was sent: true 20:36:11.744 SERIAL « 0x01070013cf0000082c (9 bytes) 20:36:11.744 SERIAL » [ACK] (0x06) 20:36:11.745 DRIVER « [REQ] [SendData] callback id: 207 transmit status: OK 20:36:11.754 SERIAL « 0x010b0004001c0570061e013fbf (13 bytes) 20:36:11.756 CNTRLR [Node 028] [+] [Configuration] 30: 63 20:36:11.757 SERIAL » [ACK] (0x06) 20:36:11.757 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 63 20:36:11.760 SERIAL » 0x010a0013030370052825d04e (12 bytes) 20:36:11.760 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 208 └─[ConfigurationCCGet] parameter #: 40 20:36:11.761 CNTRLR « [Node 028] parameter #30 has value: 63 20:36:11.761 CNTRLR » [Node 028] querying parameter #31 value... 20:36:11.764 SERIAL « [ACK] (0x06) 20:36:11.766 SERIAL « 0x0104011301e8 (6 bytes) 20:36:11.766 SERIAL » [ACK] (0x06) 20:36:11.767 DRIVER « [RES] [SendData] was sent: true 20:36:11.785 SERIAL « 0x01070013d000000239 (9 bytes) 20:36:11.786 SERIAL » [ACK] (0x06) 20:36:11.786 DRIVER « [REQ] [SendData] callback id: 208 transmit status: OK 20:36:11.798 SERIAL « 0x010c00040003067006280261a867 (14 bytes) 20:36:11.800 CNTRLR [Node 003] [+] [Configuration] 40: 25000 20:36:11.801 SERIAL » [ACK] (0x06) 20:36:11.802 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 2 value: 25000 20:36:11.806 SERIAL » 0x010900130502750425d167 (11 bytes) 20:36:11.807 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 209 └─[ProtectionCCSupportedGet] 20:36:11.807 CNTRLR « [Node 003] parameter #40 has value: 25000 20:36:11.807 CNTRLR » [Node 003] querying parameter #41 value... 20:36:11.811 SERIAL « [ACK] (0x06) 20:36:11.813 SERIAL « 0x0104011301e8 (6 bytes) 20:36:11.813 SERIAL » [ACK] (0x06) 20:36:11.814 DRIVER « [RES] [SendData] was sent: true 20:36:11.827 SERIAL « 0x01070013d100000238 (9 bytes) 20:36:11.827 SERIAL » [ACK] (0x06) 20:36:11.827 DRIVER « [REQ] [SendData] callback id: 209 transmit status: OK 20:36:11.838 SERIAL « 0x010d00040005077505020700070086 (15 bytes) 20:36:11.838 CNTRLR [Node 005] [+] [Protection] supportsExclusiveControl: [Endpoint 0] [internal] true 20:36:11.838 CNTRLR [Node 005] [+] [Protection] supportsTimeout: false [Endpoint 0] [internal] 20:36:11.838 CNTRLR [Node 005] [+] [Protection] supportedLocalStates: 0,1, [Endpoint 0] [internal] 2 20:36:11.839 CNTRLR [Node 005] [+] [Protection] supportedRFStates: 0,1,2 [Endpoint 0] [internal] 20:36:11.839 CNTRLR [Node 005] [Protection] local: metadata updated [Endpoint 0] 20:36:11.839 CNTRLR [Node 005] [Protection] rf: metadata updated [Endpoint 0] 20:36:11.840 SERIAL » [ACK] (0x06) 20:36:11.840 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[ProtectionCCSupportedReport] supports exclusive control: true supports timeout: false local protection states: · Unprotected · ProtectedBySequence · NoOperationPossible RF protection states: · Unprotected · NoControl · NoResponse 20:36:11.842 SERIAL » 0x010900130602750425d267 (11 bytes) 20:36:11.842 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 210 └─[ProtectionCCSupportedGet] 20:36:11.842 CNTRLR « [Node 005] received protection capabilities: exclusive control: true timeout: false local protection states: · Unprotected · ProtectedBySequence · NoOperationPossible RF protection states: · Unprotected · NoControl · NoResponse 20:36:11.842 CNTRLR » [Node 005] querying protection status... 20:36:11.844 SERIAL « [ACK] (0x06) 20:36:11.847 SERIAL « 0x0104011301e8 (6 bytes) 20:36:11.847 SERIAL » [ACK] (0x06) 20:36:11.847 DRIVER « [RES] [SendData] was sent: true 20:36:11.862 SERIAL « 0x01070013d20000023b (9 bytes) 20:36:11.862 SERIAL » [ACK] (0x06) 20:36:11.863 DRIVER « [REQ] [SendData] callback id: 210 transmit status: OK 20:36:11.872 SERIAL « 0x010d00040006077505020700070085 (15 bytes) 20:36:11.873 CNTRLR [Node 006] [+] [Protection] supportsExclusiveControl: [Endpoint 0] [internal] true 20:36:11.873 CNTRLR [Node 006] [+] [Protection] supportsTimeout: false [Endpoint 0] [internal] 20:36:11.873 CNTRLR [Node 006] [+] [Protection] supportedLocalStates: 0,1, [Endpoint 0] [internal] 2 20:36:11.873 CNTRLR [Node 006] [+] [Protection] supportedRFStates: 0,1,2 [Endpoint 0] [internal] 20:36:11.873 CNTRLR [Node 006] [Protection] local: metadata updated [Endpoint 0] 20:36:11.874 CNTRLR [Node 006] [Protection] rf: metadata updated [Endpoint 0] 20:36:11.874 SERIAL » [ACK] (0x06) 20:36:11.874 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ProtectionCCSupportedReport] supports exclusive control: true supports timeout: false local protection states: · Unprotected · ProtectedBySequence · NoOperationPossible RF protection states: · Unprotected · NoControl · NoResponse 20:36:11.875 SERIAL » 0x010900130202850525d393 (11 bytes) 20:36:11.876 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 211 └─[AssociationCCSupportedGroupingsGet] 20:36:11.876 CNTRLR « [Node 006] received protection capabilities: exclusive control: true timeout: false local protection states: · Unprotected · ProtectedBySequence · NoOperationPossible RF protection states: · Unprotected · NoControl · NoResponse 20:36:11.876 CNTRLR » [Node 006] querying protection status... 20:36:11.878 SERIAL « [ACK] (0x06) 20:36:11.880 SERIAL « 0x0104011301e8 (6 bytes) 20:36:11.881 SERIAL » [ACK] (0x06) 20:36:11.881 DRIVER « [RES] [SendData] was sent: true 20:36:11.900 SERIAL « 0x01070013d30000033b (9 bytes) 20:36:11.900 SERIAL » [ACK] (0x06) 20:36:11.901 DRIVER « [REQ] [SendData] callback id: 211 transmit status: OK 20:36:11.926 SERIAL « 0x0109000400020385060171 (11 bytes) 20:36:11.928 CNTRLR [Node 002] [+] [Association] groupCount: 1 [Endpoint 0] [internal] 20:36:11.928 SERIAL » [ACK] (0x06) 20:36:11.929 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[AssociationCCSupportedGroupingsReport] group count: 1 20:36:11.932 SERIAL » 0x010a0013130370051f25d46d (12 bytes) 20:36:11.932 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 212 └─[ConfigurationCCGet] parameter #: 31 20:36:11.933 CNTRLR « [Node 002] supports 1 association groups 20:36:11.933 CNTRLR » [Node 002] querying association group #1... 20:36:11.936 SERIAL « [ACK] (0x06) 20:36:11.938 SERIAL « 0x0104011301e8 (6 bytes) 20:36:11.938 SERIAL » [ACK] (0x06) 20:36:11.938 DRIVER « [RES] [SendData] was sent: true 20:36:12.080 SERIAL « 0x01070013d400000e31 (9 bytes) 20:36:12.080 SERIAL » [ACK] (0x06) 20:36:12.081 DRIVER « [REQ] [SendData] callback id: 212 transmit status: OK 20:36:12.206 SERIAL « 0x010b000400130570061f01008e (13 bytes) 20:36:12.208 CNTRLR [Node 019] [+] [Configuration] 31: 0 20:36:12.209 SERIAL » [ACK] (0x06) 20:36:12.210 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 0 20:36:12.212 SERIAL » 0x010b001312043201780025d54a (13 bytes) 20:36:12.213 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 213 └─[MeterCCGet] rate type: Consumed duration: kVar 20:36:12.213 CNTRLR « [Node 019] parameter #31 has value: 0 20:36:12.213 CNTRLR » [Node 019] querying parameter #32 value... 20:36:12.216 SERIAL « [ACK] (0x06) 20:36:12.220 SERIAL « 0x0104011301e8 (6 bytes) 20:36:12.220 SERIAL » [ACK] (0x06) 20:36:12.220 DRIVER « [RES] [SendData] was sent: true 20:36:12.334 SERIAL « 0x01070013d500000c32 (9 bytes) 20:36:12.335 SERIAL » [ACK] (0x06) 20:36:12.335 DRIVER « [REQ] [SendData] callback id: 213 transmit status: OK 20:36:12.345 SERIAL « 0x0111000400120b3202a17c000000000000001e (19 bytes) 20:36:12.346 CNTRLR [Node 018] [Meter] value[67329]: metadata updated [Endpoint 0] 20:36:12.347 CNTRLR [Node 018] [Meter] previousValue[67329]: metadata updated [Endpoint 0] 20:36:12.348 CNTRLR [Node 018] [Meter] deltaTime[67329]: metadata updated [Endpoint 0] 20:36:12.348 CNTRLR [Node 018] [+] [Meter] value[67329]: 0 [Endpoint 0] 20:36:12.349 CNTRLR [Node 018] [+] [Meter] deltaTime[67329]: 0 [Endpoint 0] 20:36:12.349 SERIAL » [ACK] (0x06) 20:36:12.350 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kVar rate type: Consumed value: 0 time delta: 0 seconds 20:36:12.353 SERIAL » 0x010900131402750225d677 (11 bytes) 20:36:12.353 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 214 └─[ProtectionCCGet] 20:36:12.353 CNTRLR » [Node 018] querying meter value (type = Electric, scale = kVarh, rate type = C onsumed)... 20:36:12.356 SERIAL « [ACK] (0x06) 20:36:12.362 SERIAL « 0x0104011301e8 (6 bytes) 20:36:12.362 SERIAL » [ACK] (0x06) 20:36:12.363 DRIVER « [RES] [SendData] was sent: true 20:36:12.378 SERIAL « 0x01070013d60000023f (9 bytes) 20:36:12.378 SERIAL » [ACK] (0x06) 20:36:12.379 DRIVER « [REQ] [SendData] callback id: 214 transmit status: OK 20:36:12.401 SERIAL « 0x010a00040014047503000097 (12 bytes) 20:36:12.402 CNTRLR [Node 020] [+] [Protection] local: 0 [Endpoint 0] 20:36:12.403 CNTRLR [Node 020] [+] [Protection] rf: 0 [Endpoint 0] 20:36:12.404 SERIAL » [ACK] (0x06) 20:36:12.405 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 20:36:12.407 SERIAL » 0x010a0013150370050225d775 (12 bytes) 20:36:12.408 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 215 └─[ConfigurationCCGet] parameter #: 2 20:36:12.408 CNTRLR « [Node 020] received protection status: local: Unprotected rf Unprotected 20:36:12.408 CNTRLR » [Node 020] querying protection timeout... 20:36:12.412 SERIAL « [ACK] (0x06) 20:36:12.414 SERIAL « 0x0104011301e8 (6 bytes) 20:36:12.414 SERIAL » [ACK] (0x06) 20:36:12.416 DRIVER « [RES] [SendData] was sent: true 20:36:13.797 SERIAL « 0x01070013d700008ab6 (9 bytes) 20:36:13.798 SERIAL » [ACK] (0x06) 20:36:13.798 DRIVER « [REQ] [SendData] callback id: 215 transmit status: OK 20:36:13.875 SERIAL « 0x010b0004001505700602011e8b (13 bytes) 20:36:13.877 CNTRLR [Node 021] [+] [Configuration] 2: 30 20:36:13.877 SERIAL » [ACK] (0x06) 20:36:13.878 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 30 20:36:13.879 SERIAL » 0x010a0013160370050225d879 (12 bytes) 20:36:13.880 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 216 └─[ConfigurationCCGet] parameter #: 2 20:36:13.880 CNTRLR « [Node 021] parameter #2 has value: 30 20:36:13.880 CNTRLR » [Node 021] querying parameter #3 value... 20:36:13.881 SERIAL « [ACK] (0x06) 20:36:13.885 SERIAL « 0x0104011301e8 (6 bytes) 20:36:13.885 SERIAL » [ACK] (0x06) 20:36:13.885 DRIVER « [RES] [SendData] was sent: true 20:36:15.487 SERIAL « 0x01070013d80000a093 (9 bytes) 20:36:15.487 SERIAL » [ACK] (0x06) 20:36:15.488 DRIVER « [REQ] [SendData] callback id: 216 transmit status: OK 20:36:15.567 SERIAL « 0x010b0004001605700602011e88 (13 bytes) 20:36:15.569 CNTRLR [Node 022] [+] [Configuration] 2: 30 20:36:15.570 SERIAL » [ACK] (0x06) 20:36:15.570 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 30 20:36:15.572 SERIAL » 0x010a0013170370050225d979 (12 bytes) 20:36:15.572 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 217 └─[ConfigurationCCGet] parameter #: 2 20:36:15.572 CNTRLR « [Node 022] parameter #2 has value: 30 20:36:15.572 CNTRLR » [Node 022] querying parameter #3 value... 20:36:15.573 SERIAL « [ACK] (0x06) 20:36:15.577 SERIAL « 0x0104011301e8 (6 bytes) 20:36:15.578 SERIAL » [ACK] (0x06) 20:36:15.578 DRIVER « [RES] [SendData] was sent: true 20:36:17.068 SERIAL « 0x01070013d9000095a7 (9 bytes) 20:36:17.069 SERIAL » [ACK] (0x06) 20:36:17.069 DRIVER « [REQ] [SendData] callback id: 217 transmit status: OK 20:36:17.147 SERIAL « 0x010b0004001705700602011e89 (13 bytes) 20:36:17.149 CNTRLR [Node 023] [+] [Configuration] 2: 30 20:36:17.150 SERIAL » [ACK] (0x06) 20:36:17.150 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 30 20:36:17.153 SERIAL » 0x010a0013180370050225da75 (12 bytes) 20:36:17.153 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 218 └─[ConfigurationCCGet] parameter #: 2 20:36:17.154 CNTRLR « [Node 023] parameter #2 has value: 30 20:36:17.154 CNTRLR » [Node 023] querying parameter #3 value... 20:36:17.157 SERIAL « [ACK] (0x06) 20:36:17.160 SERIAL « 0x0104011301e8 (6 bytes) 20:36:17.160 SERIAL » [ACK] (0x06) 20:36:17.160 DRIVER « [RES] [SendData] was sent: true 20:36:18.712 SERIAL « 0x01070013da00009cad (9 bytes) 20:36:18.712 SERIAL » [ACK] (0x06) 20:36:18.713 DRIVER « [REQ] [SendData] callback id: 218 transmit status: OK 20:36:18.788 SERIAL « 0x010b0004001805700602011e86 (13 bytes) 20:36:18.790 CNTRLR [Node 024] [+] [Configuration] 2: 30 20:36:18.791 SERIAL » [ACK] (0x06) 20:36:18.792 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 30 20:36:18.795 SERIAL » 0x010a00131a0370051f25db6b (12 bytes) 20:36:18.795 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 219 └─[ConfigurationCCGet] parameter #: 31 20:36:18.795 CNTRLR « [Node 024] parameter #2 has value: 30 20:36:18.795 CNTRLR » [Node 024] querying parameter #3 value... 20:36:18.799 SERIAL « [ACK] (0x06) 20:36:18.801 SERIAL « 0x0104011301e8 (6 bytes) 20:36:18.801 SERIAL » [ACK] (0x06) 20:36:18.802 DRIVER « [RES] [SendData] was sent: true 20:36:18.900 SERIAL « 0x01070013db00000b3b (9 bytes) 20:36:18.900 SERIAL » [ACK] (0x06) 20:36:18.901 DRIVER « [REQ] [SendData] callback id: 219 transmit status: OK 20:36:18.971 SERIAL « 0x010b0004001a0570061f010087 (13 bytes) 20:36:18.973 CNTRLR [Node 026] [+] [Configuration] 31: 0 20:36:18.974 SERIAL » [ACK] (0x06) 20:36:18.974 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 0 20:36:18.976 SERIAL » 0x010a00131c0370051f25dc6a (12 bytes) 20:36:18.976 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 220 └─[ConfigurationCCGet] parameter #: 31 20:36:18.976 CNTRLR « [Node 026] parameter #31 has value: 0 20:36:18.976 CNTRLR » [Node 026] querying parameter #32 value... 20:36:18.977 SERIAL « [ACK] (0x06) 20:36:18.981 SERIAL « 0x0104011301e8 (6 bytes) 20:36:18.981 SERIAL » [ACK] (0x06) 20:36:18.982 DRIVER « [RES] [SendData] was sent: true 20:36:19.054 SERIAL « 0x01070013dc0000083f (9 bytes) 20:36:19.055 SERIAL » [ACK] (0x06) 20:36:19.055 DRIVER « [REQ] [SendData] callback id: 220 transmit status: OK 20:36:19.064 SERIAL « 0x010b0004001c0570061f010081 (13 bytes) 20:36:19.066 CNTRLR [Node 028] [+] [Configuration] 31: 0 20:36:19.067 SERIAL » [ACK] (0x06) 20:36:19.068 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 0 20:36:19.070 SERIAL » 0x010a0013030370052925dd42 (12 bytes) 20:36:19.070 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 221 └─[ConfigurationCCGet] parameter #: 41 20:36:19.071 CNTRLR « [Node 028] parameter #31 has value: 0 20:36:19.071 CNTRLR » [Node 028] querying parameter #32 value... 20:36:19.074 SERIAL « [ACK] (0x06) 20:36:19.076 SERIAL « 0x0104011301e8 (6 bytes) 20:36:19.076 SERIAL » [ACK] (0x06) 20:36:19.077 DRIVER « [RES] [SendData] was sent: true 20:36:19.096 SERIAL « 0x01070013dd00000234 (9 bytes) 20:36:19.096 SERIAL » [ACK] (0x06) 20:36:19.096 DRIVER « [REQ] [SendData] callback id: 221 transmit status: OK 20:36:19.108 SERIAL « 0x010b00040003057006290101a9 (13 bytes) 20:36:19.110 CNTRLR [Node 003] [+] [Configuration] 41: 1 20:36:19.111 SERIAL » [ACK] (0x06) 20:36:19.111 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 41 value size: 1 value: 1 20:36:19.114 SERIAL » 0x010900130502750225de6e (11 bytes) 20:36:19.114 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 222 └─[ProtectionCCGet] 20:36:19.115 CNTRLR « [Node 003] parameter #41 has value: 1 20:36:19.115 CNTRLR » [Node 003] querying parameter #42 value... 20:36:19.117 SERIAL « [ACK] (0x06) 20:36:19.120 SERIAL « 0x0104011301e8 (6 bytes) 20:36:19.120 SERIAL » [ACK] (0x06) 20:36:19.121 DRIVER « [RES] [SendData] was sent: true 20:36:19.135 SERIAL « 0x01070013de00000237 (9 bytes) 20:36:19.135 SERIAL » [ACK] (0x06) 20:36:19.136 DRIVER « [REQ] [SendData] callback id: 222 transmit status: OK 20:36:19.144 SERIAL « 0x010a00040005047503000086 (12 bytes) 20:36:19.145 CNTRLR [Node 005] [+] [Protection] local: 0 [Endpoint 0] 20:36:19.146 CNTRLR [Node 005] [+] [Protection] rf: 0 [Endpoint 0] 20:36:19.146 SERIAL » [ACK] (0x06) 20:36:19.147 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 20:36:19.150 SERIAL » 0x010900130602750225df6c (11 bytes) 20:36:19.150 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 223 └─[ProtectionCCGet] 20:36:19.150 CNTRLR « [Node 005] received protection status: local: Unprotected rf Unprotected 20:36:19.150 CNTRLR » [Node 005] querying exclusive control node... 20:36:19.155 SERIAL « [ACK] (0x06) 20:36:19.157 SERIAL « 0x0104011301e8 (6 bytes) 20:36:19.157 SERIAL » [ACK] (0x06) 20:36:19.159 DRIVER « [RES] [SendData] was sent: true 20:36:19.170 SERIAL « 0x01070013df00000236 (9 bytes) 20:36:19.171 SERIAL » [ACK] (0x06) 20:36:19.171 DRIVER « [REQ] [SendData] callback id: 223 transmit status: OK 20:36:19.180 SERIAL « 0x010a00040006047503000085 (12 bytes) 20:36:19.181 CNTRLR [Node 006] [+] [Protection] local: 0 [Endpoint 0] 20:36:19.182 CNTRLR [Node 006] [+] [Protection] rf: 0 [Endpoint 0] 20:36:19.182 SERIAL » [ACK] (0x06) 20:36:19.183 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 20:36:19.186 SERIAL » 0x010a0013020385020125e0a4 (12 bytes) 20:36:19.186 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 224 └─[AssociationCCGet] group id: 1 20:36:19.187 CNTRLR « [Node 006] received protection status: local: Unprotected rf Unprotected 20:36:19.187 CNTRLR » [Node 006] querying exclusive control node... 20:36:19.191 SERIAL « [ACK] (0x06) 20:36:19.193 SERIAL « 0x0104011301e8 (6 bytes) 20:36:19.193 SERIAL » [ACK] (0x06) 20:36:19.194 DRIVER « [RES] [SendData] was sent: true 20:36:19.211 SERIAL « 0x01070013e000000308 (9 bytes) 20:36:19.211 SERIAL » [ACK] (0x06) 20:36:19.212 DRIVER « [REQ] [SendData] callback id: 224 transmit status: OK 20:36:19.237 SERIAL « 0x010c000400020685030101000174 (14 bytes) 20:36:19.237 SERIAL » [ACK] (0x06) 20:36:19.238 CNTRLR [Node 002] [+] [Association] maxNodes[1]: 1 [internal] 20:36:19.238 CNTRLR [Node 002] [+] [Association] nodeIds[1]: 1 [internal] 20:36:19.239 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 1 max # of nodes: 1 node IDs: 1 reports to follow: 0 20:36:19.244 SERIAL » 0x010a0013130370052025e167 (12 bytes) 20:36:19.244 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 225 └─[ConfigurationCCGet] parameter #: 32 20:36:19.245 CNTRLR « [Node 002] received information for association group #1: maximum # of nodes: 1 currently assigned nodes: 1 20:36:19.245 CNTRLR [Node 002] [+] [Association] hasLifeline: true [internal] 20:36:19.246 CNTRLR [Node 002] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 20:36:19.250 SERIAL « [ACK] (0x06) 20:36:19.251 SERIAL « 0x0104011301e8 (6 bytes) 20:36:19.251 SERIAL » [ACK] (0x06) 20:36:19.251 DRIVER « [RES] [SendData] was sent: true 20:36:19.253 CNTRLR [Node 002] AssociationGroupInfoCC: doing a complete interview... 20:36:19.254 CNTRLR » [Node 002] Association group #1: Querying name... 20:36:19.391 SERIAL « 0x01070013e100000f05 (9 bytes) 20:36:19.392 SERIAL » [ACK] (0x06) 20:36:19.392 DRIVER « [REQ] [SendData] callback id: 225 transmit status: OK 20:36:19.518 SERIAL « 0x010c0004001306700620020258ec (14 bytes) 20:36:19.520 CNTRLR [Node 019] [+] [Configuration] 32: 600 20:36:19.521 SERIAL » [ACK] (0x06) 20:36:19.522 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 2 value: 600 20:36:19.524 SERIAL » 0x010b001312043201780125e27c (13 bytes) 20:36:19.525 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 226 └─[MeterCCGet] rate type: Consumed duration: kVarh 20:36:19.525 CNTRLR « [Node 019] parameter #32 has value: 600 20:36:19.525 CNTRLR » [Node 019] querying parameter #40 value... 20:36:19.528 SERIAL « [ACK] (0x06) 20:36:19.530 SERIAL « 0x0104011301e8 (6 bytes) 20:36:19.530 SERIAL » [ACK] (0x06) 20:36:19.531 DRIVER « [RES] [SendData] was sent: true 20:36:19.644 SERIAL « 0x01070013e200000c05 (9 bytes) 20:36:19.645 SERIAL » [ACK] (0x06) 20:36:19.645 DRIVER « [REQ] [SendData] callback id: 226 transmit status: OK 20:36:19.656 SERIAL « 0x0115000400120f3202a15c000000114c1f00000011016c (23 bytes) 20:36:19.657 CNTRLR [Node 018] [Meter] value[67585]: metadata updated [Endpoint 0] 20:36:19.657 CNTRLR [Node 018] [Meter] previousValue[67585]: metadata updated [Endpoint 0] 20:36:19.658 CNTRLR [Node 018] [Meter] deltaTime[67585]: metadata updated [Endpoint 0] 20:36:19.658 CNTRLR [Node 018] [+] [Meter] value[67585]: 0.17 [Endpoint 0] 20:36:19.659 CNTRLR [Node 018] [+] [Meter] previousValue[67585]: 0.17 [Endpoint 0] 20:36:19.659 CNTRLR [Node 018] [+] [Meter] deltaTime[67585]: 19487 [Endpoint 0] 20:36:19.660 SERIAL » [ACK] (0x06) 20:36:19.661 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kVarh rate type: Consumed value: 0.17 time delta: 19487 seconds prev. value: 0.17 20:36:19.665 SERIAL » 0x010900131402750a25e34a (11 bytes) 20:36:19.665 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 227 └─[ProtectionCCTimeoutGet] 20:36:19.666 CNTRLR [Node 018] [+] [Meter] interviewComplete: true [Endpoint 0] [internal] 20:36:19.670 SERIAL « [ACK] (0x06) 20:36:19.671 SERIAL « 0x0104011301e8 (6 bytes) 20:36:19.671 SERIAL » [ACK] (0x06) 20:36:19.671 DRIVER « [RES] [SendData] was sent: true 20:36:19.672 CNTRLR [Node 018] ProtectionCC: doing a complete interview... 20:36:19.672 CNTRLR » [Node 018] querying protection capabilities... 20:36:19.690 SERIAL « 0x01070013e30000030b (9 bytes) 20:36:19.690 SERIAL » [ACK] (0x06) 20:36:19.690 DRIVER « [REQ] [SendData] callback id: 227 transmit status: OK 20:36:19.713 SERIAL « 0x01090004001403750b009b (11 bytes) 20:36:19.714 CNTRLR [Node 020] [+] [Protection] timeout: [Timeout: none] [Endpoint 0] 20:36:19.714 SERIAL » [ACK] (0x06) 20:36:19.715 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[ProtectionCCTimeoutReport] timeout: [Timeout: none] 20:36:19.718 SERIAL » 0x010a0013150370050325e447 (12 bytes) 20:36:19.718 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 228 └─[ConfigurationCCGet] parameter #: 3 20:36:19.718 CNTRLR « [Node 020] received timeout: [Timeout: none] 20:36:19.718 CNTRLR » [Node 020] querying exclusive control node... 20:36:19.721 SERIAL « [ACK] (0x06) 20:36:19.723 SERIAL « 0x0104011301e8 (6 bytes) 20:36:19.724 SERIAL » [ACK] (0x06) 20:36:19.724 DRIVER « [RES] [SendData] was sent: true 20:36:21.072 SERIAL « 0x010c0004001c0631050422029b66 (14 bytes) 20:36:21.074 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:36:21.075 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 57.1 => 66.7 [Endpoint 0] 20:36:21.076 SERIAL » [ACK] (0x06) 20:36:21.077 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 66.7 20:36:21.095 SERIAL « 0x01070013e400008986 (9 bytes) 20:36:21.096 SERIAL » [ACK] (0x06) 20:36:21.096 DRIVER « [REQ] [SendData] callback id: 228 transmit status: OK 20:36:21.120 SERIAL « 0x010c0004001c0631050422029b66 (14 bytes) 20:36:21.121 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:36:21.124 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 66.7 => 66.7 [Endpoint 0] 20:36:21.124 SERIAL » [ACK] (0x06) 20:36:21.126 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 66.7 20:36:21.179 SERIAL « 0x010b0004001505700603010094 (13 bytes) 20:36:21.181 CNTRLR [Node 021] [+] [Configuration] 3: 0 20:36:21.182 SERIAL » [ACK] (0x06) 20:36:21.183 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 20:36:21.187 SERIAL » 0x010a0013160370050325e545 (12 bytes) 20:36:21.188 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 229 └─[ConfigurationCCGet] parameter #: 3 20:36:21.188 CNTRLR « [Node 021] parameter #3 has value: 0 20:36:21.188 CNTRLR » [Node 021] querying parameter #4 value... 20:36:21.193 SERIAL « [ACK] (0x06) 20:36:21.195 SERIAL « 0x0104011301e8 (6 bytes) 20:36:21.195 SERIAL » [ACK] (0x06) 20:36:21.196 DRIVER « [RES] [SendData] was sent: true 20:36:22.840 SERIAL « 0x01070013e50000a4aa (9 bytes) 20:36:22.840 SERIAL » [ACK] (0x06) 20:36:22.841 DRIVER « [REQ] [SendData] callback id: 229 transmit status: OK 20:36:22.969 SERIAL « 0x010b0004001605700603010097 (13 bytes) 20:36:22.971 CNTRLR [Node 022] [+] [Configuration] 3: 0 20:36:22.972 SERIAL » [ACK] (0x06) 20:36:22.973 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 20:36:22.976 SERIAL » 0x010a0013170370050325e647 (12 bytes) 20:36:22.976 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 230 └─[ConfigurationCCGet] parameter #: 3 20:36:22.976 CNTRLR « [Node 022] parameter #3 has value: 0 20:36:22.976 CNTRLR » [Node 022] querying parameter #4 value... 20:36:22.978 SERIAL « [ACK] (0x06) 20:36:22.981 SERIAL « 0x0104011301e8 (6 bytes) 20:36:22.981 SERIAL » [ACK] (0x06) 20:36:22.981 DRIVER « [RES] [SendData] was sent: true 20:36:24.441 SERIAL « 0x01070013e60000939e (9 bytes) 20:36:24.441 SERIAL » [ACK] (0x06) 20:36:24.442 DRIVER « [REQ] [SendData] callback id: 230 transmit status: OK 20:36:24.521 SERIAL « 0x010b0004001705700603010096 (13 bytes) 20:36:24.523 CNTRLR [Node 023] [+] [Configuration] 3: 0 20:36:24.523 SERIAL » [ACK] (0x06) 20:36:24.524 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 20:36:24.527 SERIAL » 0x010a0013180370050325e749 (12 bytes) 20:36:24.528 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 231 └─[ConfigurationCCGet] parameter #: 3 20:36:24.528 CNTRLR « [Node 023] parameter #3 has value: 0 20:36:24.528 CNTRLR » [Node 023] querying parameter #4 value... 20:36:24.532 SERIAL « [ACK] (0x06) 20:36:24.535 SERIAL « 0x0104011301e8 (6 bytes) 20:36:24.535 SERIAL » [ACK] (0x06) 20:36:24.536 DRIVER « [RES] [SendData] was sent: true 20:36:26.116 SERIAL « 0x01070013e700009e92 (9 bytes) 20:36:26.117 SERIAL » [ACK] (0x06) 20:36:26.118 DRIVER « [REQ] [SendData] callback id: 231 transmit status: OK 20:36:26.267 SERIAL « 0x010b0004001805700603010099 (13 bytes) 20:36:26.269 CNTRLR [Node 024] [+] [Configuration] 3: 0 20:36:26.270 SERIAL » [ACK] (0x06) 20:36:26.271 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 20:36:26.272 SERIAL » 0x010a00131a0370052025e867 (12 bytes) 20:36:26.272 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 232 └─[ConfigurationCCGet] parameter #: 32 20:36:26.272 CNTRLR « [Node 024] parameter #3 has value: 0 20:36:26.272 CNTRLR » [Node 024] querying parameter #4 value... 20:36:26.274 SERIAL « [ACK] (0x06) 20:36:26.278 SERIAL « 0x0104011301e8 (6 bytes) 20:36:26.278 SERIAL » [ACK] (0x06) 20:36:26.278 DRIVER « [RES] [SendData] was sent: true 20:36:26.380 SERIAL « 0x01070013e800000b08 (9 bytes) 20:36:26.380 SERIAL » [ACK] (0x06) 20:36:26.381 DRIVER « [REQ] [SendData] callback id: 232 transmit status: OK 20:36:26.451 SERIAL « 0x010c0004001a06700620020258e5 (14 bytes) 20:36:26.453 CNTRLR [Node 026] [+] [Configuration] 32: 600 20:36:26.454 SERIAL » [ACK] (0x06) 20:36:26.455 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 2 value: 600 20:36:26.458 SERIAL » 0x010a00131c0370052025e960 (12 bytes) 20:36:26.458 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 233 └─[ConfigurationCCGet] parameter #: 32 20:36:26.459 CNTRLR « [Node 026] parameter #32 has value: 600 20:36:26.459 CNTRLR » [Node 026] querying parameter #40 value... 20:36:26.462 SERIAL « [ACK] (0x06) 20:36:26.465 SERIAL « 0x0104011301e8 (6 bytes) 20:36:26.465 SERIAL » [ACK] (0x06) 20:36:26.467 DRIVER « [RES] [SendData] was sent: true 20:36:26.534 SERIAL « 0x01070013e900000705 (9 bytes) 20:36:26.535 SERIAL » [ACK] (0x06) 20:36:26.535 DRIVER « [REQ] [SendData] callback id: 233 transmit status: OK 20:36:26.544 SERIAL « 0x010c0004001c06700620020258e3 (14 bytes) 20:36:26.549 CNTRLR [Node 028] [+] [Configuration] 32: 600 20:36:26.549 SERIAL » [ACK] (0x06) 20:36:26.550 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 2 value: 600 20:36:26.553 SERIAL » 0x010a0013030370052a25ea76 (12 bytes) 20:36:26.554 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 234 └─[ConfigurationCCGet] parameter #: 42 20:36:26.554 CNTRLR « [Node 028] parameter #32 has value: 600 20:36:26.554 CNTRLR » [Node 028] querying parameter #40 value... 20:36:26.558 SERIAL « [ACK] (0x06) 20:36:26.560 SERIAL « 0x0104011301e8 (6 bytes) 20:36:26.560 SERIAL » [ACK] (0x06) 20:36:26.561 DRIVER « [RES] [SendData] was sent: true 20:36:26.579 SERIAL « 0x01070013ea00000203 (9 bytes) 20:36:26.579 SERIAL » [ACK] (0x06) 20:36:26.580 DRIVER « [REQ] [SendData] callback id: 234 transmit status: OK 20:36:26.591 SERIAL « 0x010b000400030570062a0100ab (13 bytes) 20:36:26.593 CNTRLR [Node 003] [+] [Configuration] 42: 0 20:36:26.594 SERIAL » [ACK] (0x06) 20:36:26.595 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 0 20:36:26.598 SERIAL » 0x010900130502750725eb5e (11 bytes) 20:36:26.599 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 235 └─[ProtectionCCExclusiveControlGet] 20:36:26.599 CNTRLR « [Node 003] parameter #42 has value: 0 20:36:26.599 CNTRLR » [Node 003] querying parameter #43 value... 20:36:26.604 SERIAL « [ACK] (0x06) 20:36:26.606 SERIAL « 0x0104011301e8 (6 bytes) 20:36:26.606 SERIAL » [ACK] (0x06) 20:36:26.607 DRIVER « [RES] [SendData] was sent: true 20:36:26.619 SERIAL « 0x01070013eb00000101 (9 bytes) 20:36:26.619 SERIAL » [ACK] (0x06) 20:36:26.620 DRIVER « [REQ] [SendData] callback id: 235 transmit status: OK 20:36:26.629 SERIAL « 0x0109000400050375080089 (11 bytes) 20:36:26.630 CNTRLR [Node 005] [+] [Protection] exclusiveControlNodeId: 0 [Endpoint 0] 20:36:26.631 SERIAL » [ACK] (0x06) 20:36:26.632 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[ProtectionCCExclusiveControlReport] exclusive control node id: 0 20:36:26.635 SERIAL » 0x010900130602750725ec5a (11 bytes) 20:36:26.635 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 236 └─[ProtectionCCExclusiveControlGet] 20:36:26.636 CNTRLR « [Node 005] no node has exclusive control 20:36:26.636 CNTRLR [Node 005] [+] [Protection] interviewComplete: true [Endpoint 0] [internal] 20:36:26.642 SERIAL « [ACK] (0x06) 20:36:26.645 SERIAL « 0x0104011301e8 (6 bytes) 20:36:26.645 SERIAL » [ACK] (0x06) 20:36:26.646 DRIVER « [RES] [SendData] was sent: true 20:36:26.650 CNTRLR [Node 005] AssociationCC: doing a complete interview... 20:36:26.651 CNTRLR » [Node 005] querying number of association groups... 20:36:26.656 SERIAL « 0x01070013ec00000205 (9 bytes) 20:36:26.656 SERIAL » [ACK] (0x06) 20:36:26.656 DRIVER « [REQ] [SendData] callback id: 236 transmit status: OK 20:36:26.665 SERIAL « 0x010900040006037508008a (11 bytes) 20:36:26.666 CNTRLR [Node 006] [+] [Protection] exclusiveControlNodeId: 0 [Endpoint 0] 20:36:26.666 SERIAL » [ACK] (0x06) 20:36:26.667 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ProtectionCCExclusiveControlReport] exclusive control node id: 0 20:36:26.670 SERIAL » 0x010a0013020359010125ed76 (12 bytes) 20:36:26.670 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 237 └─[AssociationGroupInfoCCNameGet] group id: 1 20:36:26.670 CNTRLR « [Node 006] no node has exclusive control 20:36:26.671 CNTRLR [Node 006] [+] [Protection] interviewComplete: true [Endpoint 0] [internal] 20:36:26.671 CNTRLR [Node 006] AssociationCC: doing a complete interview... 20:36:26.671 CNTRLR » [Node 006] querying number of association groups... 20:36:26.673 SERIAL « [ACK] (0x06) 20:36:26.675 SERIAL « 0x0104011301e8 (6 bytes) 20:36:26.675 SERIAL » [ACK] (0x06) 20:36:26.676 DRIVER « [RES] [SendData] was sent: true 20:36:26.695 SERIAL « 0x01070013ed00000204 (9 bytes) 20:36:26.695 SERIAL » [ACK] (0x06) 20:36:26.696 DRIVER « [REQ] [SendData] callback id: 237 transmit status: OK 20:36:26.725 SERIAL « 0x0112000400020c590201084c6966656c696e659d (20 bytes) 20:36:26.726 CNTRLR [Node 002] [+] [Association Group Information] name[1]: "Lifeline" [internal] 20:36:26.727 SERIAL » [ACK] (0x06) 20:36:26.728 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 1 name: Lifeline 20:36:26.731 SERIAL » 0x010a0013130370052825ee60 (12 bytes) 20:36:26.732 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 238 └─[ConfigurationCCGet] parameter #: 40 20:36:26.732 CNTRLR « [Node 002] Association group #1 has name "Lifeline" 20:36:26.732 CNTRLR » [Node 002] Association group #1: Querying info... 20:36:26.736 SERIAL « [ACK] (0x06) 20:36:26.737 SERIAL « 0x0104011301e8 (6 bytes) 20:36:26.738 SERIAL » [ACK] (0x06) 20:36:26.738 DRIVER « [RES] [SendData] was sent: true 20:36:26.879 SERIAL « 0x01070013ee00000e0b (9 bytes) 20:36:26.880 SERIAL » [ACK] (0x06) 20:36:26.880 DRIVER « [REQ] [SendData] callback id: 238 transmit status: OK 20:36:27.008 SERIAL « 0x010c00040013067006280261a877 (14 bytes) 20:36:27.010 CNTRLR [Node 019] [+] [Configuration] 40: 25000 20:36:27.011 SERIAL » [ACK] (0x06) 20:36:27.012 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 2 value: 25000 20:36:27.018 SERIAL » 0x010900131202750425ef4e (11 bytes) 20:36:27.018 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 239 └─[ProtectionCCSupportedGet] 20:36:27.019 CNTRLR « [Node 019] parameter #40 has value: 25000 20:36:27.019 CNTRLR » [Node 019] querying parameter #41 value... 20:36:27.023 SERIAL « [ACK] (0x06) 20:36:27.025 SERIAL « 0x0104011301e8 (6 bytes) 20:36:27.025 SERIAL » [ACK] (0x06) 20:36:27.030 DRIVER « [RES] [SendData] was sent: true 20:36:27.134 SERIAL « 0x01070013ef00000b0f (9 bytes) 20:36:27.135 SERIAL » [ACK] (0x06) 20:36:27.136 DRIVER « [REQ] [SendData] callback id: 239 transmit status: OK 20:36:27.144 SERIAL « 0x010d00040012077505020700070091 (15 bytes) 20:36:27.145 CNTRLR [Node 018] [+] [Protection] supportsExclusiveControl: [Endpoint 0] [internal] true 20:36:27.146 CNTRLR [Node 018] [+] [Protection] supportsTimeout: false [Endpoint 0] [internal] 20:36:27.146 CNTRLR [Node 018] [+] [Protection] supportedLocalStates: 0,1, [Endpoint 0] [internal] 2 20:36:27.146 CNTRLR [Node 018] [+] [Protection] supportedRFStates: 0,1,2 [Endpoint 0] [internal] 20:36:27.147 CNTRLR [Node 018] [Protection] local: metadata updated [Endpoint 0] 20:36:27.148 CNTRLR [Node 018] [Protection] rf: metadata updated [Endpoint 0] 20:36:27.148 SERIAL » [ACK] (0x06) 20:36:27.149 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[ProtectionCCSupportedReport] supports exclusive control: true supports timeout: false local protection states: · Unprotected · ProtectedBySequence · NoOperationPossible RF protection states: · Unprotected · NoControl · NoResponse 20:36:27.153 SERIAL » 0x010900131402750725f054 (11 bytes) 20:36:27.153 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 240 └─[ProtectionCCExclusiveControlGet] 20:36:27.153 CNTRLR « [Node 018] received protection capabilities: exclusive control: true timeout: false local protection states: · Unprotected · ProtectedBySequence · NoOperationPossible RF protection states: · Unprotected · NoControl · NoResponse 20:36:27.154 CNTRLR » [Node 018] querying protection status... 20:36:27.158 SERIAL « [ACK] (0x06) 20:36:27.160 SERIAL « 0x0104011301e8 (6 bytes) 20:36:27.161 SERIAL » [ACK] (0x06) 20:36:27.163 DRIVER « [RES] [SendData] was sent: true 20:36:27.178 SERIAL « 0x01070013f000000219 (9 bytes) 20:36:27.178 SERIAL » [ACK] (0x06) 20:36:27.179 DRIVER « [REQ] [SendData] callback id: 240 transmit status: OK 20:36:27.201 SERIAL « 0x0109000400140375080098 (11 bytes) 20:36:27.202 CNTRLR [Node 020] [+] [Protection] exclusiveControlNodeId: 0 [Endpoint 0] 20:36:27.203 SERIAL » [ACK] (0x06) 20:36:27.204 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[ProtectionCCExclusiveControlReport] exclusive control node id: 0 20:36:27.207 SERIAL » 0x010a0013150370050425f155 (12 bytes) 20:36:27.208 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 241 └─[ConfigurationCCGet] parameter #: 4 20:36:27.208 CNTRLR « [Node 020] no node has exclusive control 20:36:27.208 CNTRLR [Node 020] [+] [Protection] interviewComplete: true [Endpoint 0] [internal] 20:36:27.215 SERIAL « [ACK] (0x06) 20:36:27.217 SERIAL « 0x0104011301e8 (6 bytes) 20:36:27.218 SERIAL » [ACK] (0x06) 20:36:27.218 DRIVER « [RES] [SendData] was sent: true 20:36:27.220 CNTRLR [Node 020] AssociationCC: doing a complete interview... 20:36:27.221 CNTRLR » [Node 020] querying number of association groups... 20:36:28.581 SERIAL « 0x01070013f100008993 (9 bytes) 20:36:28.581 SERIAL » [ACK] (0x06) 20:36:28.582 DRIVER « [REQ] [SendData] callback id: 241 transmit status: OK 20:36:28.664 SERIAL « 0x010b0004001505700604010192 (13 bytes) 20:36:28.667 CNTRLR [Node 021] [+] [Configuration] 4: 1 20:36:28.667 SERIAL » [ACK] (0x06) 20:36:28.668 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 1 value: 1 20:36:28.670 SERIAL » 0x010a0013160370050425f255 (12 bytes) 20:36:28.670 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 242 └─[ConfigurationCCGet] parameter #: 4 20:36:28.670 CNTRLR « [Node 021] parameter #4 has value: 1 20:36:28.671 CNTRLR » [Node 021] querying parameter #5 value... 20:36:28.672 SERIAL « [ACK] (0x06) 20:36:28.675 SERIAL « 0x0104011301e8 (6 bytes) 20:36:28.675 SERIAL » [ACK] (0x06) 20:36:28.676 DRIVER « [RES] [SendData] was sent: true 20:36:30.513 SERIAL « 0x01070013f20000b8a1 (9 bytes) 20:36:30.514 SERIAL » [ACK] (0x06) 20:36:30.514 DRIVER « [REQ] [SendData] callback id: 242 transmit status: OK 20:36:30.581 SERIAL « 0x010b0004001605700604010191 (13 bytes) 20:36:30.583 CNTRLR [Node 022] [+] [Configuration] 4: 1 20:36:30.584 SERIAL » [ACK] (0x06) 20:36:30.585 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 1 value: 1 20:36:30.588 SERIAL » 0x010a0013170370050425f355 (12 bytes) 20:36:30.588 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 243 └─[ConfigurationCCGet] parameter #: 4 20:36:30.589 CNTRLR « [Node 022] parameter #4 has value: 1 20:36:30.589 CNTRLR » [Node 022] querying parameter #5 value... 20:36:30.592 SERIAL « [ACK] (0x06) 20:36:30.594 SERIAL « 0x0104011301e8 (6 bytes) 20:36:30.594 SERIAL » [ACK] (0x06) 20:36:30.596 DRIVER « [RES] [SendData] was sent: true 20:36:31.999 SERIAL « 0x01070013f300008c94 (9 bytes) 20:36:31.999 SERIAL » [ACK] (0x06) 20:36:32.000 DRIVER « [REQ] [SendData] callback id: 243 transmit status: OK 20:36:32.084 SERIAL « 0x010b0004001705700604010190 (13 bytes) 20:36:32.086 CNTRLR [Node 023] [+] [Configuration] 4: 1 20:36:32.086 SERIAL » [ACK] (0x06) 20:36:32.087 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 1 value: 1 20:36:32.090 SERIAL » 0x010a0013180370050425f45d (12 bytes) 20:36:32.091 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 244 └─[ConfigurationCCGet] parameter #: 4 20:36:32.091 CNTRLR « [Node 023] parameter #4 has value: 1 20:36:32.091 CNTRLR » [Node 023] querying parameter #5 value... 20:36:32.095 SERIAL « [ACK] (0x06) 20:36:32.096 SERIAL « 0x0104011301e8 (6 bytes) 20:36:32.096 SERIAL » [ACK] (0x06) 20:36:32.098 DRIVER « [RES] [SendData] was sent: true 20:36:33.599 SERIAL « 0x01070013f400009689 (9 bytes) 20:36:33.599 SERIAL » [ACK] (0x06) 20:36:33.600 DRIVER « [REQ] [SendData] callback id: 244 transmit status: OK 20:36:33.682 SERIAL « 0x010b000400180570060401019f (13 bytes) 20:36:33.683 CNTRLR [Node 024] [+] [Configuration] 4: 1 20:36:33.684 SERIAL » [ACK] (0x06) 20:36:33.685 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 1 value: 1 20:36:33.688 SERIAL » 0x010a00131a0370052825f572 (12 bytes) 20:36:33.689 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 245 └─[ConfigurationCCGet] parameter #: 40 20:36:33.689 CNTRLR « [Node 024] parameter #4 has value: 1 20:36:33.689 CNTRLR » [Node 024] querying parameter #5 value... 20:36:33.690 SERIAL « [ACK] (0x06) 20:36:33.693 SERIAL « 0x0104011301e8 (6 bytes) 20:36:33.694 SERIAL » [ACK] (0x06) 20:36:33.694 DRIVER « [RES] [SendData] was sent: true 20:36:33.800 SERIAL « 0x01070013f500000b15 (9 bytes) 20:36:33.800 SERIAL » [ACK] (0x06) 20:36:33.801 DRIVER « [REQ] [SendData] callback id: 245 transmit status: OK 20:36:33.871 SERIAL « 0x010c0004001a067006280261a87e (14 bytes) 20:36:33.873 CNTRLR [Node 026] [+] [Configuration] 40: 25000 20:36:33.876 SERIAL » [ACK] (0x06) 20:36:33.877 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 2 value: 25000 20:36:33.880 SERIAL » 0x010a00131c0370052825f677 (12 bytes) 20:36:33.881 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 246 └─[ConfigurationCCGet] parameter #: 40 20:36:33.881 CNTRLR « [Node 026] parameter #40 has value: 25000 20:36:33.881 CNTRLR » [Node 026] querying parameter #41 value... 20:36:33.885 SERIAL « [ACK] (0x06) 20:36:33.887 SERIAL « 0x0104011301e8 (6 bytes) 20:36:33.888 SERIAL » [ACK] (0x06) 20:36:33.888 DRIVER « [RES] [SendData] was sent: true 20:36:33.954 SERIAL « 0x01070013f60000071a (9 bytes) 20:36:33.955 SERIAL » [ACK] (0x06) 20:36:33.957 DRIVER « [REQ] [SendData] callback id: 246 transmit status: OK 20:36:33.964 SERIAL « 0x010c0004001c067006280261a878 (14 bytes) 20:36:33.966 CNTRLR [Node 028] [+] [Configuration] 40: 25000 20:36:33.967 SERIAL » [ACK] (0x06) 20:36:33.968 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 2 value: 25000 20:36:33.973 SERIAL » 0x010a0013030370052b25f76a (12 bytes) 20:36:33.974 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 247 └─[ConfigurationCCGet] parameter #: 43 20:36:33.974 CNTRLR « [Node 028] parameter #40 has value: 25000 20:36:33.974 CNTRLR » [Node 028] querying parameter #41 value... 20:36:33.979 SERIAL « [ACK] (0x06) 20:36:33.980 SERIAL « 0x0104011301e8 (6 bytes) 20:36:33.980 SERIAL » [ACK] (0x06) 20:36:33.981 DRIVER « [RES] [SendData] was sent: true 20:36:33.999 SERIAL « 0x01070013f70000021e (9 bytes) 20:36:33.999 SERIAL » [ACK] (0x06) 20:36:34.000 DRIVER « [REQ] [SendData] callback id: 247 transmit status: OK 20:36:34.011 SERIAL « 0x010b000400030570062b0102a8 (13 bytes) 20:36:34.014 CNTRLR [Node 003] [+] [Configuration] 43: 2 20:36:34.016 SERIAL » [ACK] (0x06) 20:36:34.017 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 2 20:36:34.022 SERIAL » 0x010900130502850525f8bf (11 bytes) 20:36:34.023 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 248 └─[AssociationCCSupportedGroupingsGet] 20:36:34.023 CNTRLR « [Node 003] parameter #43 has value: 2 20:36:34.023 CNTRLR » [Node 003] querying parameter #50 value... 20:36:34.038 SERIAL « [ACK] (0x06) 20:36:34.038 SERIAL « 0x0104011301e8 (6 bytes) 20:36:34.039 SERIAL » [ACK] (0x06) 20:36:34.039 DRIVER « [RES] [SendData] was sent: true 20:36:34.043 SERIAL « 0x01070013f800000211 (9 bytes) 20:36:34.043 SERIAL » [ACK] (0x06) 20:36:34.043 DRIVER « [REQ] [SendData] callback id: 248 transmit status: OK 20:36:34.053 SERIAL « 0x0109000400050385060176 (11 bytes) 20:36:34.053 CNTRLR [Node 005] [+] [Association] groupCount: 1 [Endpoint 0] [internal] 20:36:34.053 SERIAL » [ACK] (0x06) 20:36:34.054 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[AssociationCCSupportedGroupingsReport] group count: 1 20:36:34.056 SERIAL » 0x010900130602850525f9bd (11 bytes) 20:36:34.056 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 249 └─[AssociationCCSupportedGroupingsGet] 20:36:34.056 CNTRLR « [Node 005] supports 1 association groups 20:36:34.057 CNTRLR » [Node 005] querying association group #1... 20:36:34.058 SERIAL « [ACK] (0x06) 20:36:34.061 SERIAL « 0x0104011301e8 (6 bytes) 20:36:34.061 SERIAL » [ACK] (0x06) 20:36:34.062 DRIVER « [RES] [SendData] was sent: true 20:36:34.077 SERIAL « 0x01070013f900000210 (9 bytes) 20:36:34.077 SERIAL » [ACK] (0x06) 20:36:34.077 DRIVER « [REQ] [SendData] callback id: 249 transmit status: OK 20:36:34.086 SERIAL « 0x0109000400060385060175 (11 bytes) 20:36:34.086 CNTRLR [Node 006] [+] [Association] groupCount: 1 [Endpoint 0] [internal] 20:36:34.086 SERIAL » [ACK] (0x06) 20:36:34.087 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationCCSupportedGroupingsReport] group count: 1 20:36:34.088 SERIAL » 0x010b001302045903000125fa65 (13 bytes) 20:36:34.089 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 250 └─[AssociationGroupInfoCCInfoGet] group id: 1 refresh cache: false 20:36:34.089 CNTRLR « [Node 006] supports 1 association groups 20:36:34.089 CNTRLR » [Node 006] querying association group #1... 20:36:34.090 SERIAL « [ACK] (0x06) 20:36:34.094 SERIAL « 0x0104011301e8 (6 bytes) 20:36:34.094 SERIAL » [ACK] (0x06) 20:36:34.095 DRIVER « [RES] [SendData] was sent: true 20:36:34.114 SERIAL « 0x01070013fa00000213 (9 bytes) 20:36:34.115 SERIAL » [ACK] (0x06) 20:36:34.115 DRIVER « [REQ] [SendData] callback id: 250 transmit status: OK 20:36:34.143 SERIAL « 0x0110000400020a59040101000000000000be (18 bytes) 20:36:34.144 CNTRLR [Node 002] [+] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false 20:36:34.144 CNTRLR [Node 002] [+] [Association Group Information] info[1]: [object Obj [internal] ect] 20:36:34.145 SERIAL » [ACK] (0x06) 20:36:34.145 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #1 mode: 0 profile: 0 event code: 0 20:36:34.147 SERIAL » 0x010a0013130370052925fb74 (12 bytes) 20:36:34.148 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 251 └─[ConfigurationCCGet] parameter #: 41 20:36:34.148 CNTRLR « [Node 002] Received info for association group #1: info is dynamic: false profile: General: N/A 20:36:34.148 CNTRLR » [Node 002] Association group #1: Querying command list... 20:36:34.151 SERIAL « [ACK] (0x06) 20:36:34.153 SERIAL « 0x0104011301e8 (6 bytes) 20:36:34.153 SERIAL » [ACK] (0x06) 20:36:34.154 DRIVER « [RES] [SendData] was sent: true 20:36:34.294 SERIAL « 0x01070013fb00000e1e (9 bytes) 20:36:34.295 SERIAL » [ACK] (0x06) 20:36:34.295 DRIVER « [REQ] [SendData] callback id: 251 transmit status: OK 20:36:34.427 SERIAL « 0x010b00040013057006290101b9 (13 bytes) 20:36:34.429 CNTRLR [Node 019] [+] [Configuration] 41: 1 20:36:34.430 SERIAL » [ACK] (0x06) 20:36:34.431 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 41 value size: 1 value: 1 20:36:34.436 SERIAL » 0x010900131202750225fc5b (11 bytes) 20:36:34.436 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 252 └─[ProtectionCCGet] 20:36:34.437 CNTRLR « [Node 019] parameter #41 has value: 1 20:36:34.437 CNTRLR » [Node 019] querying parameter #42 value... 20:36:34.440 SERIAL « [ACK] (0x06) 20:36:34.442 SERIAL « 0x0104011301e8 (6 bytes) 20:36:34.442 SERIAL » [ACK] (0x06) 20:36:34.444 DRIVER « [RES] [SendData] was sent: true 20:36:34.554 SERIAL « 0x01070013fc00000c1b (9 bytes) 20:36:34.555 SERIAL » [ACK] (0x06) 20:36:34.555 DRIVER « [REQ] [SendData] callback id: 252 transmit status: OK 20:36:34.564 SERIAL « 0x010a00040012047503000091 (12 bytes) 20:36:34.565 CNTRLR [Node 018] [+] [Protection] local: 0 [Endpoint 0] 20:36:34.566 CNTRLR [Node 018] [+] [Protection] rf: 0 [Endpoint 0] 20:36:34.566 SERIAL » [ACK] (0x06) 20:36:34.567 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 20:36:34.570 SERIAL » 0x010900131402850525fdab (11 bytes) 20:36:34.570 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 253 └─[AssociationCCSupportedGroupingsGet] 20:36:34.571 CNTRLR « [Node 018] received protection status: local: Unprotected rf Unprotected 20:36:34.571 CNTRLR » [Node 018] querying exclusive control node... 20:36:34.575 SERIAL « [ACK] (0x06) 20:36:34.577 SERIAL « 0x0104011301e8 (6 bytes) 20:36:34.577 SERIAL » [ACK] (0x06) 20:36:34.579 DRIVER « [RES] [SendData] was sent: true 20:36:34.595 SERIAL « 0x01070013fd00000214 (9 bytes) 20:36:34.595 SERIAL » [ACK] (0x06) 20:36:34.596 DRIVER « [REQ] [SendData] callback id: 253 transmit status: OK 20:36:34.621 SERIAL « 0x0109000400140385060167 (11 bytes) 20:36:34.622 CNTRLR [Node 020] [+] [Association] groupCount: 1 [Endpoint 0] [internal] 20:36:34.622 SERIAL » [ACK] (0x06) 20:36:34.623 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[AssociationCCSupportedGroupingsReport] group count: 1 20:36:34.626 SERIAL » 0x010a0013150370050525fe5b (12 bytes) 20:36:34.627 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 254 └─[ConfigurationCCGet] parameter #: 5 20:36:34.627 CNTRLR « [Node 020] supports 1 association groups 20:36:34.627 CNTRLR » [Node 020] querying association group #1... 20:36:34.630 SERIAL « [ACK] (0x06) 20:36:34.632 SERIAL « 0x0104011301e8 (6 bytes) 20:36:34.633 SERIAL » [ACK] (0x06) 20:36:34.633 DRIVER « [RES] [SendData] was sent: true 20:36:35.999 SERIAL « 0x01070013fe0000899c (9 bytes) 20:36:35.999 SERIAL » [ACK] (0x06) 20:36:36.000 DRIVER « [REQ] [SendData] callback id: 254 transmit status: OK 20:36:36.077 SERIAL « 0x010b0004001505700605010597 (13 bytes) 20:36:36.079 CNTRLR [Node 021] [+] [Configuration] 5: 5 20:36:36.080 SERIAL » [ACK] (0x06) 20:36:36.081 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 1 value: 5 20:36:36.085 SERIAL » 0x010a0013160370050525ff59 (12 bytes) 20:36:36.086 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 255 └─[ConfigurationCCGet] parameter #: 5 20:36:36.086 CNTRLR « [Node 021] parameter #5 has value: 5 20:36:36.086 CNTRLR » [Node 021] querying parameter #6 value... 20:36:36.091 SERIAL « [ACK] (0x06) 20:36:36.092 SERIAL « 0x0104011301e8 (6 bytes) 20:36:36.092 SERIAL » [ACK] (0x06) 20:36:36.093 DRIVER « [RES] [SendData] was sent: true 20:36:37.774 SERIAL « 0x01070013ff0000a9bd (9 bytes) 20:36:37.774 SERIAL » [ACK] (0x06) 20:36:37.775 DRIVER « [REQ] [SendData] callback id: 255 transmit status: OK 20:36:37.870 SERIAL « 0x010b0004001605700605010293 (13 bytes) 20:36:37.872 CNTRLR [Node 022] [+] [Configuration] 5: 2 20:36:37.873 SERIAL » [ACK] (0x06) 20:36:37.873 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 1 value: 2 20:36:37.875 SERIAL » 0x010a001317037005052501a6 (12 bytes) 20:36:37.875 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 1 └─[ConfigurationCCGet] parameter #: 5 20:36:37.875 CNTRLR « [Node 022] parameter #5 has value: 2 20:36:37.875 CNTRLR » [Node 022] querying parameter #6 value... 20:36:37.877 SERIAL « [ACK] (0x06) 20:36:37.881 SERIAL « 0x0104011301e8 (6 bytes) 20:36:37.881 SERIAL » [ACK] (0x06) 20:36:37.881 DRIVER « [RES] [SendData] was sent: true 20:36:39.271 SERIAL « 0x010700130100008c66 (9 bytes) 20:36:39.271 SERIAL » [ACK] (0x06) 20:36:39.272 DRIVER « [REQ] [SendData] callback id: 1 transmit status: OK 20:36:39.356 SERIAL « 0x010b0004001705700605010292 (13 bytes) 20:36:39.356 CNTRLR [Node 023] [+] [Configuration] 5: 2 20:36:39.357 SERIAL » [ACK] (0x06) 20:36:39.357 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 1 value: 2 20:36:39.361 SERIAL » 0x010a001318037005052502aa (12 bytes) 20:36:39.361 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 2 └─[ConfigurationCCGet] parameter #: 5 20:36:39.362 CNTRLR « [Node 023] parameter #5 has value: 2 20:36:39.362 CNTRLR » [Node 023] querying parameter #6 value... 20:36:39.364 SERIAL « [ACK] (0x06) 20:36:39.367 SERIAL « 0x0104011301e8 (6 bytes) 20:36:39.367 SERIAL » [ACK] (0x06) 20:36:39.368 DRIVER « [RES] [SendData] was sent: true 20:36:40.869 SERIAL « 0x01070013020000967f (9 bytes) 20:36:40.870 SERIAL » [ACK] (0x06) 20:36:40.870 DRIVER « [REQ] [SendData] callback id: 2 transmit status: OK 20:36:40.954 SERIAL « 0x010b000400180570060501029d (13 bytes) 20:36:40.956 CNTRLR [Node 024] [+] [Configuration] 5: 2 20:36:40.957 SERIAL » [ACK] (0x06) 20:36:40.958 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 1 value: 2 20:36:40.960 SERIAL » 0x010a00131a03700529250385 (12 bytes) 20:36:40.960 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 3 └─[ConfigurationCCGet] parameter #: 41 20:36:40.960 CNTRLR « [Node 024] parameter #5 has value: 2 20:36:40.960 CNTRLR » [Node 024] querying parameter #6 value... 20:36:40.962 SERIAL « [ACK] (0x06) 20:36:40.965 SERIAL « 0x0104011301e8 (6 bytes) 20:36:40.965 SERIAL » [ACK] (0x06) 20:36:40.966 DRIVER « [RES] [SendData] was sent: true 20:36:41.070 SERIAL « 0x010700130300000be3 (9 bytes) 20:36:41.070 SERIAL » [ACK] (0x06) 20:36:41.071 DRIVER « [REQ] [SendData] callback id: 3 transmit status: OK 20:36:41.141 SERIAL « 0x010b0004001a057006290101b0 (13 bytes) 20:36:41.143 CNTRLR [Node 026] [+] [Configuration] 41: 1 20:36:41.144 SERIAL » [ACK] (0x06) 20:36:41.145 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 41 value size: 1 value: 1 20:36:41.148 SERIAL » 0x010a00131c03700529250484 (12 bytes) 20:36:41.148 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 4 └─[ConfigurationCCGet] parameter #: 41 20:36:41.149 CNTRLR « [Node 026] parameter #41 has value: 1 20:36:41.149 CNTRLR » [Node 026] querying parameter #42 value... 20:36:41.152 SERIAL « [ACK] (0x06) 20:36:41.155 SERIAL « 0x0104011301e8 (6 bytes) 20:36:41.156 SERIAL » [ACK] (0x06) 20:36:41.156 DRIVER « [RES] [SendData] was sent: true 20:36:41.224 SERIAL « 0x0107001304000007e8 (9 bytes) 20:36:41.225 SERIAL » [ACK] (0x06) 20:36:41.225 DRIVER « [REQ] [SendData] callback id: 4 transmit status: OK 20:36:41.234 SERIAL « 0x010b0004001c057006290101b6 (13 bytes) 20:36:41.236 CNTRLR [Node 028] [+] [Configuration] 41: 1 20:36:41.237 SERIAL » [ACK] (0x06) 20:36:41.238 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 41 value size: 1 value: 1 20:36:41.245 SERIAL » 0x010a00130303700532250581 (12 bytes) 20:36:41.246 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 5 └─[ConfigurationCCGet] parameter #: 50 20:36:41.246 CNTRLR « [Node 028] parameter #41 has value: 1 20:36:41.246 CNTRLR » [Node 028] querying parameter #42 value... 20:36:41.251 SERIAL « [ACK] (0x06) 20:36:41.255 SERIAL « 0x0104011301e8 (6 bytes) 20:36:41.255 SERIAL » [ACK] (0x06) 20:36:41.256 DRIVER « [RES] [SendData] was sent: true 20:36:41.271 SERIAL « 0x0107001305000003ed (9 bytes) 20:36:41.271 SERIAL » [ACK] (0x06) 20:36:41.271 DRIVER « [REQ] [SendData] callback id: 5 transmit status: OK 20:36:41.283 SERIAL « 0x010b00040003057006320103b0 (13 bytes) 20:36:41.284 CNTRLR [Node 003] [+] [Configuration] 50: 3 20:36:41.285 SERIAL » [ACK] (0x06) 20:36:41.286 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 3 20:36:41.287 SERIAL » 0x010a00130503850201250645 (12 bytes) 20:36:41.287 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 6 └─[AssociationCCGet] group id: 1 20:36:41.287 CNTRLR « [Node 003] parameter #50 has value: 3 20:36:41.288 CNTRLR [Node 003] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 20:36:41.291 SERIAL « [ACK] (0x06) 20:36:41.292 CNTRLR [Node 003] MeterCC: doing a complete interview... 20:36:41.292 CNTRLR » [Node 003] querying meter support... 20:36:41.295 SERIAL « 0x0104011301e8 (6 bytes) 20:36:41.295 SERIAL » [ACK] (0x06) 20:36:41.295 DRIVER « [RES] [SendData] was sent: true 20:36:41.308 SERIAL « 0x0107001306000001ec (9 bytes) 20:36:41.308 SERIAL » [ACK] (0x06) 20:36:41.308 DRIVER « [REQ] [SendData] callback id: 6 transmit status: OK 20:36:41.318 SERIAL « 0x010c000400050685030101000173 (14 bytes) 20:36:41.318 SERIAL » [ACK] (0x06) 20:36:41.319 CNTRLR [Node 005] [+] [Association] maxNodes[1]: 1 [internal] 20:36:41.319 CNTRLR [Node 005] [+] [Association] nodeIds[1]: 1 [internal] 20:36:41.319 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 1 max # of nodes: 1 node IDs: 1 reports to follow: 0 20:36:41.320 SERIAL » 0x010a00130603850201250747 (12 bytes) 20:36:41.321 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 7 └─[AssociationCCGet] group id: 1 20:36:41.321 CNTRLR « [Node 005] received information for association group #1: maximum # of nodes: 1 currently assigned nodes: 1 20:36:41.321 CNTRLR [Node 005] [+] [Association] hasLifeline: true [internal] 20:36:41.321 CNTRLR [Node 005] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 20:36:41.321 CNTRLR [Node 005] AssociationGroupInfoCC: doing a complete interview... 20:36:41.321 CNTRLR » [Node 005] Association group #1: Querying name... 20:36:41.323 SERIAL « [ACK] (0x06) 20:36:41.326 SERIAL « 0x0104011301e8 (6 bytes) 20:36:41.326 SERIAL » [ACK] (0x06) 20:36:41.326 DRIVER « [RES] [SendData] was sent: true 20:36:41.341 SERIAL « 0x0107001307000002ee (9 bytes) 20:36:41.341 SERIAL » [ACK] (0x06) 20:36:41.341 DRIVER « [REQ] [SendData] callback id: 7 transmit status: OK 20:36:41.351 SERIAL « 0x010c000400060685030101000170 (14 bytes) 20:36:41.352 SERIAL » [ACK] (0x06) 20:36:41.352 CNTRLR [Node 006] [+] [Association] maxNodes[1]: 1 [internal] 20:36:41.352 CNTRLR [Node 006] [+] [Association] nodeIds[1]: 1 [internal] 20:36:41.353 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 1 max # of nodes: 1 node IDs: 1 reports to follow: 0 20:36:41.357 SERIAL » 0x010b0013020459058001250811 (13 bytes) 20:36:41.358 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 8 └─[AssociationGroupInfoCCCommandListGet] group id: 1 allow cache: true 20:36:41.358 CNTRLR « [Node 006] received information for association group #1: maximum # of nodes: 1 currently assigned nodes: 1 20:36:41.359 CNTRLR [Node 006] [+] [Association] hasLifeline: true [internal] 20:36:41.359 CNTRLR [Node 006] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 20:36:41.359 CNTRLR [Node 006] AssociationGroupInfoCC: doing a complete interview... 20:36:41.360 CNTRLR » [Node 006] Association group #1: Querying name... 20:36:41.362 SERIAL « [ACK] (0x06) 20:36:41.364 SERIAL « 0x0104011301e8 (6 bytes) 20:36:41.364 SERIAL » [ACK] (0x06) 20:36:41.364 DRIVER « [RES] [SendData] was sent: true 20:36:41.383 SERIAL « 0x0107001308000002e1 (9 bytes) 20:36:41.383 SERIAL » [ACK] (0x06) 20:36:41.384 DRIVER « [REQ] [SendData] callback id: 8 transmit status: OK 20:36:41.412 SERIAL « 0x0112000400020c590601087105320225035a0188 (20 bytes) 20:36:41.414 CNTRLR [Node 002] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[1]: [object Map] 20:36:41.414 SERIAL » [ACK] (0x06) 20:36:41.415 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 1 commands: · Notification: 0x05 · Meter: 0x02 · Binary Switch: 0x03 · Device Reset Locally: 0x01 20:36:41.418 SERIAL » 0x010a0013130370052a250985 (12 bytes) 20:36:41.419 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 9 └─[ConfigurationCCGet] parameter #: 42 20:36:41.419 CNTRLR [Node 002] [+] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true 20:36:41.421 CNTRLR [Node 002] NotificationCC: doing a complete interview... 20:36:41.422 CNTRLR [Node 002] [+] [Notification] interviewComplete: true [Endpoint 0] [internal] 20:36:41.422 CNTRLR [Node 002] Interview stage completed: CommandClasses 20:36:41.422 CNTRLR [Node 002] Interview stage completed: OverwriteConfig 20:36:41.423 CNTRLR » [Node 002] requesting node neighbors... 20:36:41.426 SERIAL « [ACK] (0x06) 20:36:41.426 SERIAL « 0x0104011301e8 (6 bytes) 20:36:41.427 SERIAL » [ACK] (0x06) 20:36:41.427 DRIVER « [RES] [SendData] was sent: true 20:36:41.565 SERIAL « 0x010700130900000eec (9 bytes) 20:36:41.566 SERIAL » [ACK] (0x06) 20:36:41.566 DRIVER « [REQ] [SendData] callback id: 9 transmit status: OK 20:36:41.696 SERIAL « 0x010b000400130570062a0100bb (13 bytes) 20:36:41.698 CNTRLR [Node 019] [+] [Configuration] 42: 0 20:36:41.699 SERIAL » [ACK] (0x06) 20:36:41.700 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 0 20:36:41.703 SERIAL » 0x01070080020000007a (9 bytes) 20:36:41.704 DRIVER » [Node 002] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 20:36:41.704 CNTRLR « [Node 019] parameter #42 has value: 0 20:36:41.704 CNTRLR » [Node 019] querying parameter #43 value... 20:36:41.708 SERIAL « [ACK] (0x06) 20:36:41.709 SERIAL « 0x0120018055cd178b0000000000000000000000000000000000000000000000000 (34 bytes) 05a 20:36:41.710 SERIAL » [ACK] (0x06) 20:36:41.711 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 5, 7, 9, 11, 12, 15, 16, 17, 18, 19, 21, 25, 26, 28, 32 20:36:41.717 SERIAL » 0x0109001312027507250aa8 (11 bytes) 20:36:41.717 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 10 └─[ProtectionCCExclusiveControlGet] 20:36:41.718 CNTRLR « [Node 002] node neighbors received: 1, 3, 5, 7, 9, 11, 12, 15, 16, 17, 18, 1 9, 21, 25, 26, 28, 32 20:36:41.718 CNTRLR [Node 002] Interview stage completed: Neighbors 20:36:41.724 SERIAL « [ACK] (0x06) 20:36:41.725 SERIAL « 0x0104011301e8 (6 bytes) 20:36:41.725 SERIAL » [ACK] (0x06) 20:36:41.726 DRIVER « [RES] [SendData] was sent: true 20:36:41.728 CNTRLR [Node 002] Interview completed 20:36:41.729 CNTRLR [Node 002] The node is ready to be used 20:36:41.824 SERIAL « 0x010700130a00000bea (9 bytes) 20:36:41.824 SERIAL » [ACK] (0x06) 20:36:41.825 DRIVER « [REQ] [SendData] callback id: 10 transmit status: OK 20:36:41.834 SERIAL « 0x010900040012037508009e (11 bytes) 20:36:41.834 CNTRLR [Node 018] [+] [Protection] exclusiveControlNodeId: 0 [Endpoint 0] 20:36:41.834 SERIAL » [ACK] (0x06) 20:36:41.835 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[ProtectionCCExclusiveControlReport] exclusive control node id: 0 20:36:41.836 SERIAL » 0x010a00131403850201250b59 (12 bytes) 20:36:41.836 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 11 └─[AssociationCCGet] group id: 1 20:36:41.836 CNTRLR « [Node 018] no node has exclusive control 20:36:41.836 CNTRLR [Node 018] [+] [Protection] interviewComplete: true [Endpoint 0] [internal] 20:36:41.837 CNTRLR [Node 018] AssociationCC: doing a complete interview... 20:36:41.837 CNTRLR » [Node 018] querying number of association groups... 20:36:41.838 SERIAL « [ACK] (0x06) 20:36:41.842 SERIAL « 0x0104011301e8 (6 bytes) 20:36:41.842 SERIAL » [ACK] (0x06) 20:36:41.842 DRIVER « [RES] [SendData] was sent: true 20:36:41.861 SERIAL « 0x010700130b000003e3 (9 bytes) 20:36:41.861 SERIAL » [ACK] (0x06) 20:36:41.862 DRIVER « [REQ] [SendData] callback id: 11 transmit status: OK 20:36:41.886 SERIAL « 0x010c000400140685030101000162 (14 bytes) 20:36:41.886 SERIAL » [ACK] (0x06) 20:36:41.886 CNTRLR [Node 020] [+] [Association] maxNodes[1]: 1 [internal] 20:36:41.886 CNTRLR [Node 020] [+] [Association] nodeIds[1]: 1 [internal] 20:36:41.887 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 1 max # of nodes: 1 node IDs: 1 reports to follow: 0 20:36:41.888 SERIAL » 0x010a00131503700506250caa (12 bytes) 20:36:41.888 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 12 └─[ConfigurationCCGet] parameter #: 6 20:36:41.889 CNTRLR « [Node 020] received information for association group #1: maximum # of nodes: 1 currently assigned nodes: 1 20:36:41.889 CNTRLR [Node 020] [+] [Association] hasLifeline: true [internal] 20:36:41.889 CNTRLR [Node 020] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 20:36:41.892 SERIAL « [ACK] (0x06) 20:36:41.894 CNTRLR [Node 020] AssociationGroupInfoCC: doing a complete interview... 20:36:41.894 CNTRLR » [Node 020] Association group #1: Querying name... 20:36:41.895 SERIAL « 0x0104011301e8 (6 bytes) 20:36:41.895 SERIAL » [ACK] (0x06) 20:36:41.896 DRIVER « [RES] [SendData] was sent: true 20:36:43.331 SERIAL « 0x010700130c00009077 (9 bytes) 20:36:43.331 SERIAL » [ACK] (0x06) 20:36:43.332 DRIVER « [REQ] [SendData] callback id: 12 transmit status: OK 20:36:43.413 SERIAL « 0x010b0004001505700606010091 (13 bytes) 20:36:43.415 CNTRLR [Node 021] [+] [Configuration] 6: 0 20:36:43.416 SERIAL » [ACK] (0x06) 20:36:43.417 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 1 value: 0 20:36:43.418 SERIAL » 0x010a00131603700506250da8 (12 bytes) 20:36:43.418 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 13 └─[ConfigurationCCGet] parameter #: 6 20:36:43.419 CNTRLR « [Node 021] parameter #6 has value: 0 20:36:43.419 CNTRLR » [Node 021] querying parameter #7 value... 20:36:43.420 SERIAL « [ACK] (0x06) 20:36:43.424 SERIAL « 0x0104011301e8 (6 bytes) 20:36:43.424 SERIAL » [ACK] (0x06) 20:36:43.424 DRIVER « [RES] [SendData] was sent: true 20:36:45.131 SERIAL « 0x010700130d0000ab4d (9 bytes) 20:36:45.132 SERIAL » [ACK] (0x06) 20:36:45.132 DRIVER « [REQ] [SendData] callback id: 13 transmit status: OK 20:36:45.216 SERIAL « 0x010b0004001605700606010092 (13 bytes) 20:36:45.218 CNTRLR [Node 022] [+] [Configuration] 6: 0 20:36:45.219 SERIAL » [ACK] (0x06) 20:36:45.220 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 1 value: 0 20:36:45.222 SERIAL » 0x010a00131703700506250eaa (12 bytes) 20:36:45.222 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 14 └─[ConfigurationCCGet] parameter #: 6 20:36:45.222 CNTRLR « [Node 022] parameter #6 has value: 0 20:36:45.222 CNTRLR » [Node 022] querying parameter #7 value... 20:36:45.224 SERIAL « [ACK] (0x06) 20:36:45.227 SERIAL « 0x0104011301e8 (6 bytes) 20:36:45.227 SERIAL » [ACK] (0x06) 20:36:45.228 DRIVER « [RES] [SendData] was sent: true 20:36:46.656 SERIAL « 0x010700130e00008f6a (9 bytes) 20:36:46.657 SERIAL » [ACK] (0x06) 20:36:46.657 DRIVER « [REQ] [SendData] callback id: 14 transmit status: OK 20:36:46.739 SERIAL « 0x010b0004001705700606010093 (13 bytes) 20:36:46.745 CNTRLR [Node 023] [+] [Configuration] 6: 0 20:36:46.746 SERIAL » [ACK] (0x06) 20:36:46.747 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 1 value: 0 20:36:46.748 SERIAL » 0x010a00131803700506250fa4 (12 bytes) 20:36:46.748 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 15 └─[ConfigurationCCGet] parameter #: 6 20:36:46.748 CNTRLR « [Node 023] parameter #6 has value: 0 20:36:46.748 CNTRLR » [Node 023] querying parameter #7 value... 20:36:46.750 SERIAL « [ACK] (0x06) 20:36:46.753 SERIAL « 0x0104011301e8 (6 bytes) 20:36:46.753 SERIAL » [ACK] (0x06) 20:36:46.753 DRIVER « [RES] [SendData] was sent: true 20:36:52.051 SERIAL « 0x010700130f010212f5 (9 bytes) 20:36:52.052 SERIAL » [ACK] (0x06) 20:36:52.052 DRIVER « [REQ] [SendData] callback id: 15 transmit status: NoAck 20:36:52.055 CNTRLR [Node 024] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 20:36:52.560 SERIAL » 0x010a00131803700506250fa4 (12 bytes) 20:36:52.561 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 15 └─[ConfigurationCCGet] parameter #: 6 20:36:52.562 SERIAL « [ACK] (0x06) 20:36:52.568 SERIAL « 0x0104011301e8 (6 bytes) 20:36:52.568 SERIAL » [ACK] (0x06) 20:36:52.569 DRIVER « [RES] [SendData] was sent: true 20:36:57.392 SERIAL « 0x010700130f0001e306 (9 bytes) 20:36:57.393 SERIAL » [ACK] (0x06) 20:36:57.393 DRIVER « [REQ] [SendData] callback id: 15 transmit status: OK 20:36:57.444 SERIAL « 0x010c0004001c06310504220232cf (14 bytes) 20:36:57.445 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:36:57.445 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 66.7 => 56.2 [Endpoint 0] 20:36:57.445 SERIAL » [ACK] (0x06) 20:36:57.446 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 56.2 20:36:57.478 SERIAL « 0x010b000400180570060601009c (13 bytes) 20:36:57.481 CNTRLR [Node 024] [+] [Configuration] 6: 0 20:36:57.482 SERIAL » [ACK] (0x06) 20:36:57.483 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 1 value: 0 20:36:57.484 SERIAL » 0x010a00131a0370052a251095 (12 bytes) 20:36:57.484 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[ConfigurationCCGet] parameter #: 42 20:36:57.485 CNTRLR « [Node 024] parameter #6 has value: 0 20:36:57.485 CNTRLR » [Node 024] querying parameter #7 value... 20:36:57.486 SERIAL « [ACK] (0x06) 20:36:57.489 SERIAL « 0x0104011301e8 (6 bytes) 20:36:57.489 SERIAL » [ACK] (0x06) 20:36:57.490 DRIVER « [RES] [SendData] was sent: true 20:36:57.531 SERIAL « 0x010b000400180570060601009c (13 bytes) 20:36:57.533 CNTRLR [Node 024] [~] [Configuration] 6: 0 => 0 20:36:57.534 SERIAL » [ACK] (0x06) 20:36:57.535 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 1 value: 0 20:36:57.888 SERIAL « 0x010b0004001a0570062a0100b2 (13 bytes) 20:36:57.890 CNTRLR [Node 026] [+] [Configuration] 42: 0 20:36:57.891 SERIAL » [ACK] (0x06) 20:36:57.892 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 0 20:36:58.063 SERIAL « 0x010b0004001a0570062a0100b2 (13 bytes) 20:36:58.065 CNTRLR [Node 026] [~] [Configuration] 42: 0 => 0 20:36:58.066 SERIAL » [ACK] (0x06) 20:36:58.067 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 0 20:36:58.154 SERIAL « 0x0107001310000043b8 (9 bytes) 20:36:58.155 SERIAL » [ACK] (0x06) 20:36:58.156 DRIVER « [REQ] [SendData] callback id: 16 transmit status: OK 20:36:58.164 SERIAL « 0x010b0004001a0570062a0100b2 (13 bytes) 20:36:58.166 CNTRLR [Node 026] [~] [Configuration] 42: 0 => 0 20:36:58.167 SERIAL » [ACK] (0x06) 20:36:58.168 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 0 20:36:58.171 SERIAL » 0x010a00131c0370052a251192 (12 bytes) 20:36:58.172 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 17 └─[ConfigurationCCGet] parameter #: 42 20:36:58.172 CNTRLR « [Node 026] parameter #42 has value: 0 20:36:58.172 CNTRLR » [Node 026] querying parameter #43 value... 20:36:58.178 SERIAL « [ACK] (0x06) 20:36:58.179 SERIAL « 0x0104011301e8 (6 bytes) 20:36:58.179 SERIAL » [ACK] (0x06) 20:36:58.180 DRIVER « [RES] [SendData] was sent: true 20:36:58.236 SERIAL « 0x0107001311000006fc (9 bytes) 20:36:58.237 SERIAL » [ACK] (0x06) 20:36:58.240 DRIVER « [REQ] [SendData] callback id: 17 transmit status: OK 20:36:58.308 SERIAL « 0x010b0004001c0570062a0100b4 (13 bytes) 20:36:58.310 CNTRLR [Node 028] [+] [Configuration] 42: 0 20:36:58.311 SERIAL » [ACK] (0x06) 20:36:58.312 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 0 20:36:58.317 SERIAL » 0x01090013030232032512e2 (11 bytes) 20:36:58.317 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 18 └─[MeterCCSupportedGet] 20:36:58.317 CNTRLR « [Node 028] parameter #42 has value: 0 20:36:58.318 CNTRLR » [Node 028] querying parameter #43 value... 20:36:58.321 SERIAL « [ACK] (0x06) 20:36:58.323 SERIAL « 0x0104011301e8 (6 bytes) 20:36:58.324 SERIAL » [ACK] (0x06) 20:36:58.325 DRIVER « [RES] [SendData] was sent: true 20:36:58.399 SERIAL « 0x0107001312000008f1 (9 bytes) 20:36:58.399 SERIAL » [ACK] (0x06) 20:36:58.400 DRIVER « [REQ] [SendData] callback id: 18 transmit status: OK 20:36:58.411 SERIAL « 0x010a00040003043204810544 (12 bytes) 20:36:58.413 CNTRLR [Node 003] [+] [Meter] type: 1 [Endpoint 0] [internal] 20:36:58.414 CNTRLR [Node 003] [+] [Meter] supportsReset: true [Endpoint 0] [internal] 20:36:58.414 CNTRLR [Node 003] [+] [Meter] supportedScales: 0,2 [Endpoint 0] [internal] 20:36:58.414 CNTRLR [Node 003] [+] [Meter] supportedRateTypes: [Endpoint 0] [internal] 20:36:58.415 CNTRLR [Node 003] [Meter] reset: metadata updated [Endpoint 0] 20:36:58.415 SERIAL » [ACK] (0x06) 20:36:58.417 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MeterCCSupportedReport] type: Electric supports reset: true supported scales: · kWh · W supported rate types: 20:36:58.420 SERIAL » 0x010a0013050359010125138f (12 bytes) 20:36:58.421 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 19 └─[AssociationGroupInfoCCNameGet] group id: 1 20:36:58.421 CNTRLR « [Node 003] received meter support: type: Electric supported scales: · kWh · W supported rate types: supports reset: true 20:36:58.421 CNTRLR » [Node 003] querying meter value (type = Electric, scale = kWh)... 20:36:58.425 SERIAL « [ACK] (0x06) 20:36:58.426 SERIAL « 0x0104011301e8 (6 bytes) 20:36:58.426 SERIAL » [ACK] (0x06) 20:36:58.427 DRIVER « [RES] [SendData] was sent: true 20:36:58.441 SERIAL « 0x0107001313000002fa (9 bytes) 20:36:58.442 SERIAL » [ACK] (0x06) 20:36:58.442 DRIVER « [REQ] [SendData] callback id: 19 transmit status: OK 20:36:58.452 SERIAL « 0x0112000400050c590201084c6966656c696e659a (20 bytes) 20:36:58.453 CNTRLR [Node 005] [+] [Association Group Information] name[1]: "Lifeline" [internal] 20:36:58.454 SERIAL » [ACK] (0x06) 20:36:58.454 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 1 name: Lifeline 20:36:58.458 SERIAL » 0x010a0013060359010125148b (12 bytes) 20:36:58.458 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 20 └─[AssociationGroupInfoCCNameGet] group id: 1 20:36:58.458 CNTRLR « [Node 005] Association group #1 has name "Lifeline" 20:36:58.459 CNTRLR » [Node 005] Association group #1: Querying info... 20:36:58.462 SERIAL « [ACK] (0x06) 20:36:58.465 SERIAL « 0x0104011301e8 (6 bytes) 20:36:58.465 SERIAL » [ACK] (0x06) 20:36:58.465 DRIVER « [RES] [SendData] was sent: true 20:36:58.479 SERIAL « 0x0107001314000001fe (9 bytes) 20:36:58.479 SERIAL » [ACK] (0x06) 20:36:58.480 DRIVER « [REQ] [SendData] callback id: 20 transmit status: OK 20:36:58.489 SERIAL « 0x0112000400060c590201084c6966656c696e6599 (20 bytes) 20:36:58.490 CNTRLR [Node 006] [+] [Association Group Information] name[1]: "Lifeline" [internal] 20:36:58.490 SERIAL » [ACK] (0x06) 20:36:58.491 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 1 name: Lifeline 20:36:58.494 SERIAL » 0x010a0013130370052b251598 (12 bytes) 20:36:58.494 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 21 └─[ConfigurationCCGet] parameter #: 43 20:36:58.494 CNTRLR « [Node 006] Association group #1 has name "Lifeline" 20:36:58.495 CNTRLR » [Node 006] Association group #1: Querying info... 20:36:58.497 SERIAL « [ACK] (0x06) 20:36:58.499 SERIAL « 0x0104011301e8 (6 bytes) 20:36:58.500 SERIAL » [ACK] (0x06) 20:36:58.500 DRIVER « [RES] [SendData] was sent: true 20:36:58.641 SERIAL « 0x010700131500000ff1 (9 bytes) 20:36:58.642 SERIAL » [ACK] (0x06) 20:36:58.642 DRIVER « [REQ] [SendData] callback id: 21 transmit status: OK 20:36:58.766 SERIAL « 0x010b000400130570062b0102b8 (13 bytes) 20:36:58.769 CNTRLR [Node 019] [+] [Configuration] 43: 2 20:36:58.770 SERIAL » [ACK] (0x06) 20:36:58.771 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 2 20:36:58.777 SERIAL » 0x0109001312028505251646 (11 bytes) 20:36:58.778 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 22 └─[AssociationCCSupportedGroupingsGet] 20:36:58.778 CNTRLR « [Node 019] parameter #43 has value: 2 20:36:58.778 CNTRLR » [Node 019] querying parameter #50 value... 20:36:58.782 SERIAL « [ACK] (0x06) 20:36:58.784 SERIAL « 0x0104011301e8 (6 bytes) 20:36:58.784 SERIAL » [ACK] (0x06) 20:36:58.786 DRIVER « [RES] [SendData] was sent: true 20:36:58.894 SERIAL « 0x010700131600000bf6 (9 bytes) 20:36:58.895 SERIAL » [ACK] (0x06) 20:36:58.895 DRIVER « [REQ] [SendData] callback id: 22 transmit status: OK 20:36:58.904 SERIAL « 0x0109000400120385060161 (11 bytes) 20:36:58.905 CNTRLR [Node 018] [+] [Association] groupCount: 1 [Endpoint 0] [internal] 20:36:58.905 SERIAL » [ACK] (0x06) 20:36:58.906 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[AssociationCCSupportedGroupingsReport] group count: 1 20:36:58.909 SERIAL » 0x010a0013140359010125179a (12 bytes) 20:36:58.910 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 23 └─[AssociationGroupInfoCCNameGet] group id: 1 20:36:58.910 CNTRLR « [Node 018] supports 1 association groups 20:36:58.910 CNTRLR » [Node 018] querying association group #1... 20:36:58.913 SERIAL « [ACK] (0x06) 20:36:58.918 SERIAL « 0x0104011301e8 (6 bytes) 20:36:58.918 SERIAL » [ACK] (0x06) 20:36:58.918 DRIVER « [RES] [SendData] was sent: true 20:36:58.935 SERIAL « 0x0107001317000002fe (9 bytes) 20:36:58.936 SERIAL » [ACK] (0x06) 20:36:58.936 DRIVER « [REQ] [SendData] callback id: 23 transmit status: OK 20:36:58.963 SERIAL « 0x0112000400140c590201084c6966656c696e658b (20 bytes) 20:36:58.964 CNTRLR [Node 020] [+] [Association Group Information] name[1]: "Lifeline" [internal] 20:36:58.964 SERIAL » [ACK] (0x06) 20:36:58.965 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 1 name: Lifeline 20:36:58.968 SERIAL » 0x010a001315037005072518bf (12 bytes) 20:36:58.968 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 24 └─[ConfigurationCCGet] parameter #: 7 20:36:58.969 CNTRLR « [Node 020] Association group #1 has name "Lifeline" 20:36:58.969 CNTRLR » [Node 020] Association group #1: Querying info... 20:36:58.971 SERIAL « [ACK] (0x06) 20:36:58.974 SERIAL « 0x0104011301e8 (6 bytes) 20:36:58.974 SERIAL » [ACK] (0x06) 20:36:58.974 DRIVER « [RES] [SendData] was sent: true 20:37:00.375 SERIAL « 0x010700131800008c7f (9 bytes) 20:37:00.376 SERIAL » [ACK] (0x06) 20:37:00.377 DRIVER « [REQ] [SendData] callback id: 24 transmit status: OK 20:37:00.453 SERIAL « 0x010b0004001505700607010090 (13 bytes) 20:37:00.454 CNTRLR [Node 021] [+] [Configuration] 7: 0 20:37:00.455 SERIAL » [ACK] (0x06) 20:37:00.456 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 7 value size: 1 value: 0 20:37:00.458 SERIAL » 0x010a001316037005072519bd (12 bytes) 20:37:00.458 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 25 └─[ConfigurationCCGet] parameter #: 7 20:37:00.458 CNTRLR « [Node 021] parameter #7 has value: 0 20:37:00.458 CNTRLR » [Node 021] querying parameter #8 value... 20:37:00.461 SERIAL « [ACK] (0x06) 20:37:00.463 SERIAL « 0x0104011301e8 (6 bytes) 20:37:00.464 SERIAL » [ACK] (0x06) 20:37:00.464 DRIVER « [RES] [SendData] was sent: true 20:37:02.085 SERIAL « 0x01070013190000a250 (9 bytes) 20:37:02.085 SERIAL » [ACK] (0x06) 20:37:02.086 DRIVER « [REQ] [SendData] callback id: 25 transmit status: OK 20:37:02.163 SERIAL « 0x010b0004001605700607010093 (13 bytes) 20:37:02.165 CNTRLR [Node 022] [+] [Configuration] 7: 0 20:37:02.166 SERIAL » [ACK] (0x06) 20:37:02.167 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 7 value size: 1 value: 0 20:37:02.169 SERIAL » 0x010a00131703700507251abf (12 bytes) 20:37:02.169 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 26 └─[ConfigurationCCGet] parameter #: 7 20:37:02.169 CNTRLR « [Node 022] parameter #7 has value: 0 20:37:02.170 CNTRLR » [Node 022] querying parameter #8 value... 20:37:02.171 SERIAL « [ACK] (0x06) 20:37:02.174 SERIAL « 0x0104011301e8 (6 bytes) 20:37:02.175 SERIAL » [ACK] (0x06) 20:37:02.175 DRIVER « [RES] [SendData] was sent: true 20:37:03.623 SERIAL « 0x010700131a00009160 (9 bytes) 20:37:03.623 SERIAL » [ACK] (0x06) 20:37:03.624 DRIVER « [REQ] [SendData] callback id: 26 transmit status: OK 20:37:03.702 SERIAL « 0x010b0004001705700607010092 (13 bytes) 20:37:03.704 CNTRLR [Node 023] [+] [Configuration] 7: 0 20:37:03.705 SERIAL » [ACK] (0x06) 20:37:03.706 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 7 value size: 1 value: 0 20:37:03.709 SERIAL » 0x010a00131803700507251bb1 (12 bytes) 20:37:03.709 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 27 └─[ConfigurationCCGet] parameter #: 7 20:37:03.709 CNTRLR « [Node 023] parameter #7 has value: 0 20:37:03.710 CNTRLR » [Node 023] querying parameter #8 value... 20:37:03.713 SERIAL « [ACK] (0x06) 20:37:03.715 SERIAL « 0x0104011301e8 (6 bytes) 20:37:03.715 SERIAL » [ACK] (0x06) 20:37:03.716 DRIVER « [RES] [SendData] was sent: true 20:37:05.458 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:37:05.459 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:37:05.460 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:37:05.460 SERIAL » [ACK] (0x06) 20:37:05.462 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:37:05.476 SERIAL « 0x010700131b0000b040 (9 bytes) 20:37:05.476 SERIAL » [ACK] (0x06) 20:37:05.477 DRIVER « [REQ] [SendData] callback id: 27 transmit status: OK 20:37:05.627 SERIAL « 0x010b000400180570060701009d (13 bytes) 20:37:05.629 CNTRLR [Node 024] [+] [Configuration] 7: 0 20:37:05.630 SERIAL » [ACK] (0x06) 20:37:05.630 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 7 value size: 1 value: 0 20:37:05.636 SERIAL » 0x010a00131a0370052b251c98 (12 bytes) 20:37:05.636 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 28 └─[ConfigurationCCGet] parameter #: 43 20:37:05.636 CNTRLR « [Node 024] parameter #7 has value: 0 20:37:05.637 CNTRLR » [Node 024] querying parameter #8 value... 20:37:05.640 SERIAL « [ACK] (0x06) 20:37:05.642 SERIAL « 0x0104011301e8 (6 bytes) 20:37:05.642 SERIAL » [ACK] (0x06) 20:37:05.643 DRIVER « [RES] [SendData] was sent: true 20:37:05.714 SERIAL « 0x010700131c000008ff (9 bytes) 20:37:05.715 SERIAL » [ACK] (0x06) 20:37:05.715 DRIVER « [REQ] [SendData] callback id: 28 transmit status: OK 20:37:05.724 SERIAL « 0x010b0004001a0570062b0102b1 (13 bytes) 20:37:05.726 CNTRLR [Node 026] [+] [Configuration] 43: 2 20:37:05.727 SERIAL » [ACK] (0x06) 20:37:05.728 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 2 20:37:05.731 SERIAL » 0x010a00131c0370052b251d9f (12 bytes) 20:37:05.732 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 29 └─[ConfigurationCCGet] parameter #: 43 20:37:05.732 CNTRLR « [Node 026] parameter #43 has value: 2 20:37:05.732 CNTRLR » [Node 026] querying parameter #50 value... 20:37:05.736 SERIAL « [ACK] (0x06) 20:37:05.743 SERIAL « 0x0104011301e8 (6 bytes) 20:37:05.743 SERIAL » [ACK] (0x06) 20:37:05.744 DRIVER « [RES] [SendData] was sent: true 20:37:05.796 SERIAL « 0x010700131d000006f0 (9 bytes) 20:37:05.796 SERIAL » [ACK] (0x06) 20:37:05.797 DRIVER « [REQ] [SendData] callback id: 29 transmit status: OK 20:37:05.867 SERIAL « 0x010b0004001c0570062b0102b7 (13 bytes) 20:37:05.869 CNTRLR [Node 028] [+] [Configuration] 43: 2 20:37:05.870 SERIAL » [ACK] (0x06) 20:37:05.871 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 2 20:37:05.876 SERIAL » 0x010a00130303320100251eee (12 bytes) 20:37:05.877 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 30 └─[MeterCCGet] duration: kWh 20:37:05.877 CNTRLR « [Node 028] parameter #43 has value: 2 20:37:05.877 CNTRLR » [Node 028] querying parameter #50 value... 20:37:05.881 SERIAL « [ACK] (0x06) 20:37:05.882 SERIAL « 0x0104011301e8 (6 bytes) 20:37:05.883 SERIAL » [ACK] (0x06) 20:37:05.884 DRIVER « [RES] [SendData] was sent: true 20:37:05.959 SERIAL « 0x010700131e000008fd (9 bytes) 20:37:05.959 SERIAL » [ACK] (0x06) 20:37:05.960 DRIVER « [REQ] [SendData] callback id: 30 transmit status: OK 20:37:05.972 SERIAL « 0x0110000400030a3202214400000cfb000040 (18 bytes) 20:37:05.973 CNTRLR [Node 003] [Meter] value[65537]: metadata updated [Endpoint 0] 20:37:05.974 CNTRLR [Node 003] [Meter] previousValue[65537]: metadata updated [Endpoint 0] 20:37:05.975 CNTRLR [Node 003] [Meter] deltaTime[65537]: metadata updated [Endpoint 0] 20:37:05.975 CNTRLR [Node 003] [+] [Meter] value[65537]: 33.23 [Endpoint 0] 20:37:05.976 CNTRLR [Node 003] [+] [Meter] deltaTime[65537]: 0 [Endpoint 0] 20:37:05.976 SERIAL » [ACK] (0x06) 20:37:05.979 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 33.23 time delta: 0 seconds 20:37:05.982 SERIAL » 0x010b0013050459030001251f87 (13 bytes) 20:37:05.982 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 31 └─[AssociationGroupInfoCCInfoGet] group id: 1 refresh cache: false 20:37:05.983 CNTRLR » [Node 003] querying meter value (type = Electric, scale = W)... 20:37:05.987 SERIAL « [ACK] (0x06) 20:37:05.989 SERIAL « 0x0104011301e8 (6 bytes) 20:37:05.989 SERIAL » [ACK] (0x06) 20:37:05.990 DRIVER « [RES] [SendData] was sent: true 20:37:06.003 SERIAL « 0x010700131f000002f6 (9 bytes) 20:37:06.004 SERIAL » [ACK] (0x06) 20:37:06.004 DRIVER « [REQ] [SendData] callback id: 31 transmit status: OK 20:37:06.014 SERIAL « 0x0110000400050a59040101000001000000b8 (18 bytes) 20:37:06.015 CNTRLR [Node 005] [+] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false 20:37:06.015 CNTRLR [Node 005] [+] [Association Group Information] info[1]: [object Obj [internal] ect] 20:37:06.016 SERIAL » [ACK] (0x06) 20:37:06.016 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #1 mode: 0 profile: 1 event code: 0 20:37:06.019 SERIAL » 0x010b00130604590300012520bb (13 bytes) 20:37:06.020 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 32 └─[AssociationGroupInfoCCInfoGet] group id: 1 refresh cache: false 20:37:06.020 CNTRLR « [Node 005] Received info for association group #1: info is dynamic: false profile: General: Lifeline 20:37:06.020 CNTRLR » [Node 005] Association group #1: Querying command list... 20:37:06.023 SERIAL « [ACK] (0x06) 20:37:06.025 SERIAL « 0x0104011301e8 (6 bytes) 20:37:06.025 SERIAL » [ACK] (0x06) 20:37:06.027 DRIVER « [RES] [SendData] was sent: true 20:37:06.040 SERIAL « 0x0107001320000002c9 (9 bytes) 20:37:06.040 SERIAL » [ACK] (0x06) 20:37:06.041 DRIVER « [REQ] [SendData] callback id: 32 transmit status: OK 20:37:06.051 SERIAL « 0x0110000400060a59040101000001000000bb (18 bytes) 20:37:06.052 CNTRLR [Node 006] [+] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false 20:37:06.052 CNTRLR [Node 006] [+] [Association Group Information] info[1]: [object Obj [internal] ect] 20:37:06.052 SERIAL » [ACK] (0x06) 20:37:06.053 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #1 mode: 0 profile: 1 event code: 0 20:37:06.056 SERIAL » 0x010a001313037005322521b5 (12 bytes) 20:37:06.056 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 33 └─[ConfigurationCCGet] parameter #: 50 20:37:06.057 CNTRLR « [Node 006] Received info for association group #1: info is dynamic: false profile: General: Lifeline 20:37:06.057 CNTRLR » [Node 006] Association group #1: Querying command list... 20:37:06.061 SERIAL « [ACK] (0x06) 20:37:06.062 SERIAL « 0x0104011301e8 (6 bytes) 20:37:06.063 SERIAL » [ACK] (0x06) 20:37:06.063 DRIVER « [RES] [SendData] was sent: true 20:37:06.203 SERIAL « 0x010700132100000ec4 (9 bytes) 20:37:06.203 SERIAL » [ACK] (0x06) 20:37:06.204 DRIVER « [REQ] [SendData] callback id: 33 transmit status: OK 20:37:06.336 SERIAL « 0x010b00040013057006320103a0 (13 bytes) 20:37:06.338 CNTRLR [Node 019] [+] [Configuration] 50: 3 20:37:06.341 SERIAL » [ACK] (0x06) 20:37:06.342 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 3 20:37:06.346 SERIAL » 0x010a00131203850201252276 (12 bytes) 20:37:06.346 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 34 └─[AssociationCCGet] group id: 1 20:37:06.347 CNTRLR « [Node 019] parameter #50 has value: 3 20:37:06.347 CNTRLR [Node 019] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 20:37:06.356 SERIAL « [ACK] (0x06) 20:37:06.358 SERIAL « 0x0104011301e8 (6 bytes) 20:37:06.358 SERIAL » [ACK] (0x06) 20:37:06.359 DRIVER « [RES] [SendData] was sent: true 20:37:06.361 CNTRLR [Node 019] MeterCC: doing a complete interview... 20:37:06.362 CNTRLR » [Node 019] querying meter support... 20:37:06.464 SERIAL « 0x010700132200000cc5 (9 bytes) 20:37:06.464 SERIAL » [ACK] (0x06) 20:37:06.465 DRIVER « [REQ] [SendData] callback id: 34 transmit status: OK 20:37:06.474 SERIAL « 0x010c000400120685030101000164 (14 bytes) 20:37:06.475 SERIAL » [ACK] (0x06) 20:37:06.476 CNTRLR [Node 018] [+] [Association] maxNodes[1]: 1 [internal] 20:37:06.476 CNTRLR [Node 018] [+] [Association] nodeIds[1]: 1 [internal] 20:37:06.476 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 1 max # of nodes: 1 node IDs: 1 reports to follow: 0 20:37:06.480 SERIAL » 0x010b00131404590300012523aa (13 bytes) 20:37:06.480 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 35 └─[AssociationGroupInfoCCInfoGet] group id: 1 refresh cache: false 20:37:06.480 CNTRLR « [Node 018] received information for association group #1: maximum # of nodes: 1 currently assigned nodes: 1 20:37:06.481 CNTRLR [Node 018] [+] [Association] hasLifeline: true [internal] 20:37:06.481 CNTRLR [Node 018] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 20:37:06.482 CNTRLR [Node 018] AssociationGroupInfoCC: doing a complete interview... 20:37:06.482 CNTRLR » [Node 018] Association group #1: Querying name... 20:37:06.485 SERIAL « [ACK] (0x06) 20:37:06.486 SERIAL « 0x0104011301e8 (6 bytes) 20:37:06.486 SERIAL » [ACK] (0x06) 20:37:06.487 DRIVER « [RES] [SendData] was sent: true 20:37:06.505 SERIAL « 0x0107001323000002ca (9 bytes) 20:37:06.506 SERIAL » [ACK] (0x06) 20:37:06.506 DRIVER « [REQ] [SendData] callback id: 35 transmit status: OK 20:37:06.534 SERIAL « 0x0110000400140a59040101000000000000a8 (18 bytes) 20:37:06.535 CNTRLR [Node 020] [+] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false 20:37:06.535 CNTRLR [Node 020] [+] [Association Group Information] info[1]: [object Obj [internal] ect] 20:37:06.536 SERIAL » [ACK] (0x06) 20:37:06.536 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #1 mode: 0 profile: 0 event code: 0 20:37:06.541 SERIAL » 0x010a0013150370050825248c (12 bytes) 20:37:06.541 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 36 └─[ConfigurationCCGet] parameter #: 8 20:37:06.542 CNTRLR « [Node 020] Received info for association group #1: info is dynamic: false profile: General: N/A 20:37:06.542 CNTRLR » [Node 020] Association group #1: Querying command list... 20:37:06.544 SERIAL « [ACK] (0x06) 20:37:06.547 SERIAL « 0x0104011301e8 (6 bytes) 20:37:06.547 SERIAL » [ACK] (0x06) 20:37:06.547 DRIVER « [RES] [SendData] was sent: true 20:37:07.914 SERIAL « 0x010700132400008946 (9 bytes) 20:37:07.914 SERIAL » [ACK] (0x06) 20:37:07.915 DRIVER « [REQ] [SendData] callback id: 36 transmit status: OK 20:37:07.992 SERIAL « 0x010b000400150570060801009f (13 bytes) 20:37:07.994 CNTRLR [Node 021] [+] [Configuration] 8: 0 20:37:07.995 SERIAL » [ACK] (0x06) 20:37:07.996 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 0 20:37:07.999 SERIAL » 0x010a0013160370050825258e (12 bytes) 20:37:07.999 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 37 └─[ConfigurationCCGet] parameter #: 8 20:37:07.999 CNTRLR « [Node 021] parameter #8 has value: 0 20:37:08.000 CNTRLR [Node 021] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 20:37:08.002 SERIAL « [ACK] (0x06) 20:37:08.003 CNTRLR [Node 021] AssociationCC: doing a complete interview... 20:37:08.003 CNTRLR » [Node 021] querying number of association groups... 20:37:08.004 SERIAL « 0x0104011301e8 (6 bytes) 20:37:08.005 SERIAL » [ACK] (0x06) 20:37:08.005 DRIVER « [RES] [SendData] was sent: true 20:37:09.642 SERIAL « 0x01070013250000a46a (9 bytes) 20:37:09.643 SERIAL » [ACK] (0x06) 20:37:09.644 DRIVER « [REQ] [SendData] callback id: 37 transmit status: OK 20:37:09.724 SERIAL « 0x010b000400160570060801009c (13 bytes) 20:37:09.726 CNTRLR [Node 022] [+] [Configuration] 8: 0 20:37:09.726 SERIAL » [ACK] (0x06) 20:37:09.727 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 0 20:37:09.732 SERIAL » 0x010a0013170370050825268c (12 bytes) 20:37:09.732 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 38 └─[ConfigurationCCGet] parameter #: 8 20:37:09.733 CNTRLR « [Node 022] parameter #8 has value: 0 20:37:09.733 CNTRLR [Node 022] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 20:37:09.738 SERIAL « [ACK] (0x06) 20:37:09.740 SERIAL « 0x0104011301e8 (6 bytes) 20:37:09.741 SERIAL » [ACK] (0x06) 20:37:09.742 DRIVER « [RES] [SendData] was sent: true 20:37:09.743 CNTRLR [Node 022] AssociationCC: doing a complete interview... 20:37:09.743 CNTRLR » [Node 022] querying number of association groups... 20:37:11.183 SERIAL « 0x01070013260000915c (9 bytes) 20:37:11.184 SERIAL » [ACK] (0x06) 20:37:11.184 DRIVER « [REQ] [SendData] callback id: 38 transmit status: OK 20:37:11.262 SERIAL « 0x010b000400170570060801009d (13 bytes) 20:37:11.264 CNTRLR [Node 023] [+] [Configuration] 8: 0 20:37:11.264 SERIAL » [ACK] (0x06) 20:37:11.265 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 0 20:37:11.268 SERIAL » 0x010a00131803700508252782 (12 bytes) 20:37:11.270 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[ConfigurationCCGet] parameter #: 8 20:37:11.271 CNTRLR « [Node 023] parameter #8 has value: 0 20:37:11.271 CNTRLR [Node 023] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 20:37:11.279 SERIAL « [ACK] (0x06) 20:37:11.280 SERIAL « 0x0104011301e8 (6 bytes) 20:37:11.281 SERIAL » [ACK] (0x06) 20:37:11.283 DRIVER « [RES] [SendData] was sent: true 20:37:11.284 CNTRLR [Node 023] AssociationCC: doing a complete interview... 20:37:11.284 CNTRLR » [Node 023] querying number of association groups... 20:37:12.711 SERIAL « 0x01070013270000905c (9 bytes) 20:37:12.712 SERIAL » [ACK] (0x06) 20:37:12.712 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 20:37:12.793 SERIAL « 0x010b0004001805700608010092 (13 bytes) 20:37:12.795 CNTRLR [Node 024] [+] [Configuration] 8: 0 20:37:12.796 SERIAL » [ACK] (0x06) 20:37:12.796 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 0 20:37:12.799 SERIAL » 0x010a00131a037005322528b5 (12 bytes) 20:37:12.800 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 40 └─[ConfigurationCCGet] parameter #: 50 20:37:12.800 CNTRLR « [Node 024] parameter #8 has value: 0 20:37:12.800 CNTRLR [Node 024] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 20:37:12.807 SERIAL « [ACK] (0x06) 20:37:12.809 SERIAL « 0x0104011301e8 (6 bytes) 20:37:12.809 SERIAL » [ACK] (0x06) 20:37:12.810 DRIVER « [RES] [SendData] was sent: true 20:37:12.813 CNTRLR [Node 024] AssociationCC: doing a complete interview... 20:37:12.813 CNTRLR » [Node 024] querying number of association groups... 20:37:12.884 SERIAL « 0x0107001328000008cb (9 bytes) 20:37:12.884 SERIAL » [ACK] (0x06) 20:37:12.885 DRIVER « [REQ] [SendData] callback id: 40 transmit status: OK 20:37:12.894 SERIAL « 0x010b0004001a057006320103a9 (13 bytes) 20:37:12.896 CNTRLR [Node 026] [+] [Configuration] 50: 3 20:37:12.897 SERIAL » [ACK] (0x06) 20:37:12.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 3 20:37:12.901 SERIAL » 0x010a00131c037005322529b2 (12 bytes) 20:37:12.901 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 41 └─[ConfigurationCCGet] parameter #: 50 20:37:12.901 CNTRLR « [Node 026] parameter #50 has value: 3 20:37:12.902 CNTRLR [Node 026] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 20:37:12.902 CNTRLR [Node 026] MeterCC: doing a complete interview... 20:37:12.902 CNTRLR » [Node 026] querying meter support... 20:37:12.907 SERIAL « [ACK] (0x06) 20:37:12.911 SERIAL « 0x0104011301e8 (6 bytes) 20:37:12.911 SERIAL » [ACK] (0x06) 20:37:12.911 DRIVER « [RES] [SendData] was sent: true 20:37:12.965 SERIAL « 0x0107001329000006c4 (9 bytes) 20:37:12.965 SERIAL » [ACK] (0x06) 20:37:12.966 DRIVER « [REQ] [SendData] callback id: 41 transmit status: OK 20:37:13.037 SERIAL « 0x010b0004001c057006320103af (13 bytes) 20:37:13.039 CNTRLR [Node 028] [+] [Configuration] 50: 3 20:37:13.040 SERIAL » [ACK] (0x06) 20:37:13.041 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 3 20:37:13.044 SERIAL » 0x010a00130303320110252aca (12 bytes) 20:37:13.044 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 42 └─[MeterCCGet] duration: W 20:37:13.044 CNTRLR « [Node 028] parameter #50 has value: 3 20:37:13.045 CNTRLR [Node 028] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 20:37:13.051 SERIAL « [ACK] (0x06) 20:37:13.053 SERIAL « 0x0104011301e8 (6 bytes) 20:37:13.053 SERIAL » [ACK] (0x06) 20:37:13.054 DRIVER « [RES] [SendData] was sent: true 20:37:13.061 CNTRLR [Node 028] MeterCC: doing a complete interview... 20:37:13.061 CNTRLR » [Node 028] querying meter support... 20:37:13.129 SERIAL « 0x010700132a000008c9 (9 bytes) 20:37:13.129 SERIAL » [ACK] (0x06) 20:37:13.130 DRIVER « [REQ] [SendData] callback id: 42 transmit status: OK 20:37:13.142 SERIAL « 0x010e00040003083202213200000000dd (16 bytes) 20:37:13.143 CNTRLR [Node 003] [Meter] value[66049]: metadata updated [Endpoint 0] 20:37:13.144 CNTRLR [Node 003] [Meter] previousValue[66049]: metadata updated [Endpoint 0] 20:37:13.144 CNTRLR [Node 003] [Meter] deltaTime[66049]: metadata updated [Endpoint 0] 20:37:13.145 CNTRLR [Node 003] [+] [Meter] value[66049]: 0 [Endpoint 0] 20:37:13.146 CNTRLR [Node 003] [+] [Meter] deltaTime[66049]: 0 [Endpoint 0] 20:37:13.146 SERIAL » [ACK] (0x06) 20:37:13.148 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:37:13.152 SERIAL » 0x010b0013050459058001252b35 (13 bytes) 20:37:13.152 DRIVER » [Node 005] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 43 └─[AssociationGroupInfoCCCommandListGet] group id: 1 allow cache: true 20:37:13.153 CNTRLR [Node 003] [+] [Meter] interviewComplete: true [Endpoint 0] [internal] 20:37:13.154 CNTRLR [Node 003] MultilevelSensorCC: doing a complete interview... 20:37:13.154 CNTRLR » [Node 003] retrieving supported sensor types... 20:37:13.158 SERIAL « [ACK] (0x06) 20:37:13.160 SERIAL « 0x0104011301e8 (6 bytes) 20:37:13.160 SERIAL » [ACK] (0x06) 20:37:13.161 DRIVER « [RES] [SendData] was sent: true 20:37:13.173 SERIAL « 0x010700132b000002c2 (9 bytes) 20:37:13.174 SERIAL » [ACK] (0x06) 20:37:13.174 DRIVER « [REQ] [SendData] callback id: 43 transmit status: OK 20:37:13.184 SERIAL « 0x0112000400050c590601087105320225035a018f (20 bytes) 20:37:13.185 CNTRLR [Node 005] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[1]: [object Map] 20:37:13.186 SERIAL » [ACK] (0x06) 20:37:13.187 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 1 commands: · Notification: 0x05 · Meter: 0x02 · Binary Switch: 0x03 · Device Reset Locally: 0x01 20:37:13.193 SERIAL » 0x010b0013060459058001252c31 (13 bytes) 20:37:13.194 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 44 └─[AssociationGroupInfoCCCommandListGet] group id: 1 allow cache: true 20:37:13.194 CNTRLR [Node 005] [+] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true 20:37:13.195 CNTRLR [Node 005] NotificationCC: doing a complete interview... 20:37:13.195 CNTRLR [Node 005] [+] [Notification] interviewComplete: true [Endpoint 0] [internal] 20:37:13.195 CNTRLR [Node 005] Interview stage completed: CommandClasses 20:37:13.195 CNTRLR [Node 005] Interview stage completed: OverwriteConfig 20:37:13.196 CNTRLR » [Node 005] requesting node neighbors... 20:37:13.197 SERIAL « [ACK] (0x06) 20:37:13.199 SERIAL « 0x0104011301e8 (6 bytes) 20:37:13.199 SERIAL » [ACK] (0x06) 20:37:13.199 DRIVER « [RES] [SendData] was sent: true 20:37:13.214 SERIAL « 0x010700132c000002c5 (9 bytes) 20:37:13.214 SERIAL » [ACK] (0x06) 20:37:13.214 DRIVER « [REQ] [SendData] callback id: 44 transmit status: OK 20:37:13.225 SERIAL « 0x0112000400060c590601087105320225035a018c (20 bytes) 20:37:13.226 CNTRLR [Node 006] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[1]: [object Map] 20:37:13.226 SERIAL » [ACK] (0x06) 20:37:13.226 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 1 commands: · Notification: 0x05 · Meter: 0x02 · Binary Switch: 0x03 · Device Reset Locally: 0x01 20:37:13.227 SERIAL » 0x01070080050000007d (9 bytes) 20:37:13.227 DRIVER » [Node 005] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 20:37:13.228 CNTRLR [Node 006] [+] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true 20:37:13.230 SERIAL « [ACK] (0x06) 20:37:13.230 CNTRLR [Node 006] NotificationCC: doing a complete interview... 20:37:13.231 CNTRLR [Node 006] [+] [Notification] interviewComplete: true [Endpoint 0] [internal] 20:37:13.231 CNTRLR [Node 006] Interview stage completed: CommandClasses 20:37:13.231 CNTRLR [Node 006] Interview stage completed: OverwriteConfig 20:37:13.231 CNTRLR » [Node 006] requesting node neighbors... 20:37:13.232 SERIAL « 0x0120018067dd9f8b0000000000000000000000000000000000000000000000000 (34 bytes) 0f0 20:37:13.232 SERIAL » [ACK] (0x06) 20:37:13.232 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 2, 3, 6, 7, 9, 11, 12, 13, 15, 16, 17, 18, 19, 20, 21, 24, 25, 26, 28, 32 20:37:13.234 SERIAL » 0x01070080060000007e (9 bytes) 20:37:13.234 DRIVER » [Node 006] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 20:37:13.234 CNTRLR « [Node 005] node neighbors received: 1, 2, 3, 6, 7, 9, 11, 12, 13, 15, 16, 17 , 18, 19, 20, 21, 24, 25, 26, 28, 32 20:37:13.234 CNTRLR [Node 005] Interview stage completed: Neighbors 20:37:13.234 CNTRLR [Node 005] Interview completed 20:37:13.235 CNTRLR [Node 005] The node is ready to be used 20:37:13.236 SERIAL « [ACK] (0x06) 20:37:13.237 SERIAL « 0x01200180d55fff890000000000000000000000000000000000000000000000000 (34 bytes) 0a2 20:37:13.237 SERIAL » [ACK] (0x06) 20:37:13.237 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 5, 7, 8, 9, 10, 11, 12, 13, 15, 17, 18, 19, 20, 21, 22, 23, 24, 25, 28, 32 20:37:13.239 SERIAL » 0x0109001313023203252dcd (11 bytes) 20:37:13.239 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 45 └─[MeterCCSupportedGet] 20:37:13.239 CNTRLR « [Node 006] node neighbors received: 1, 3, 5, 7, 8, 9, 10, 11, 12, 13, 15, 17 , 18, 19, 20, 21, 22, 23, 24, 25, 28, 32 20:37:13.239 CNTRLR [Node 006] Interview stage completed: Neighbors 20:37:13.239 CNTRLR [Node 006] Interview completed 20:37:13.239 CNTRLR [Node 006] The node is ready to be used 20:37:13.241 SERIAL « [ACK] (0x06) 20:37:13.265 SERIAL « 0x0104011301e8 (6 bytes) 20:37:13.266 SERIAL » [ACK] (0x06) 20:37:13.266 DRIVER « [RES] [SendData] was sent: true 20:37:13.477 SERIAL « 0x010700132d000017d1 (9 bytes) 20:37:13.477 SERIAL » [ACK] (0x06) 20:37:13.477 DRIVER « [REQ] [SendData] callback id: 45 transmit status: OK 20:37:13.605 SERIAL « 0x010a00040013043204810554 (12 bytes) 20:37:13.606 CNTRLR [Node 019] [+] [Meter] type: 1 [Endpoint 0] [internal] 20:37:13.606 CNTRLR [Node 019] [+] [Meter] supportsReset: true [Endpoint 0] [internal] 20:37:13.606 CNTRLR [Node 019] [+] [Meter] supportedScales: 0,2 [Endpoint 0] [internal] 20:37:13.607 CNTRLR [Node 019] [+] [Meter] supportedRateTypes: [Endpoint 0] [internal] 20:37:13.607 CNTRLR [Node 019] [Meter] reset: metadata updated [Endpoint 0] 20:37:13.608 SERIAL » [ACK] (0x06) 20:37:13.608 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MeterCCSupportedReport] type: Electric supports reset: true supported scales: · kWh · W supported rate types: 20:37:13.611 SERIAL » 0x010a00131203590101252ea5 (12 bytes) 20:37:13.612 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 46 └─[AssociationGroupInfoCCNameGet] group id: 1 20:37:13.612 CNTRLR « [Node 019] received meter support: type: Electric supported scales: · kWh · W supported rate types: supports reset: true 20:37:13.612 CNTRLR » [Node 019] querying meter value (type = Electric, scale = kWh)... 20:37:13.615 SERIAL « [ACK] (0x06) 20:37:13.617 SERIAL « 0x0104011301e8 (6 bytes) 20:37:13.617 SERIAL » [ACK] (0x06) 20:37:13.619 DRIVER « [RES] [SendData] was sent: true 20:37:13.734 SERIAL « 0x010700132e00000cc9 (9 bytes) 20:37:13.735 SERIAL » [ACK] (0x06) 20:37:13.735 DRIVER « [REQ] [SendData] callback id: 46 transmit status: OK 20:37:13.745 SERIAL « 0x0112000400120c590201084c6966656c696e658d (20 bytes) 20:37:13.746 CNTRLR [Node 018] [+] [Association Group Information] name[1]: "Lifeline" [internal] 20:37:13.746 SERIAL » [ACK] (0x06) 20:37:13.747 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 1 name: Lifeline 20:37:13.750 SERIAL » 0x010b0013140459058001252f20 (13 bytes) 20:37:13.750 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 47 └─[AssociationGroupInfoCCCommandListGet] group id: 1 allow cache: true 20:37:13.750 CNTRLR « [Node 018] Association group #1 has name "Lifeline" 20:37:13.750 CNTRLR » [Node 018] Association group #1: Querying info... 20:37:13.753 SERIAL « [ACK] (0x06) 20:37:13.755 SERIAL « 0x0104011301e8 (6 bytes) 20:37:13.756 SERIAL » [ACK] (0x06) 20:37:13.756 DRIVER « [RES] [SendData] was sent: true 20:37:13.775 SERIAL « 0x010700132f000002c6 (9 bytes) 20:37:13.776 SERIAL » [ACK] (0x06) 20:37:13.776 DRIVER « [REQ] [SendData] callback id: 47 transmit status: OK 20:37:13.804 SERIAL « 0x0112000400140c590601087105320225035a019e (20 bytes) 20:37:13.805 CNTRLR [Node 020] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[1]: [object Map] 20:37:13.806 SERIAL » [ACK] (0x06) 20:37:13.806 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 1 commands: · Notification: 0x05 · Meter: 0x02 · Binary Switch: 0x03 · Device Reset Locally: 0x01 20:37:13.809 SERIAL » 0x0109001315028505253067 (11 bytes) 20:37:13.809 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 48 └─[AssociationCCSupportedGroupingsGet] 20:37:13.810 CNTRLR [Node 020] [+] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true 20:37:13.814 SERIAL « [ACK] (0x06) 20:37:13.816 SERIAL « 0x0104011301e8 (6 bytes) 20:37:13.817 SERIAL » [ACK] (0x06) 20:37:13.817 DRIVER « [RES] [SendData] was sent: true 20:37:13.819 CNTRLR [Node 020] NotificationCC: doing a complete interview... 20:37:13.820 CNTRLR [Node 020] [+] [Notification] interviewComplete: true [Endpoint 0] [internal] 20:37:13.820 CNTRLR [Node 020] Interview stage completed: CommandClasses 20:37:13.820 CNTRLR [Node 020] Interview stage completed: OverwriteConfig 20:37:13.820 CNTRLR » [Node 020] requesting node neighbors... 20:37:15.180 SERIAL « 0x010700133000008952 (9 bytes) 20:37:15.181 SERIAL » [ACK] (0x06) 20:37:15.181 DRIVER « [REQ] [SendData] callback id: 48 transmit status: OK 20:37:15.262 SERIAL « 0x0109000400150385060166 (11 bytes) 20:37:15.263 CNTRLR [Node 021] [+] [Association] groupCount: 1 [Endpoint 0] [internal] 20:37:15.263 SERIAL » [ACK] (0x06) 20:37:15.264 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[AssociationCCSupportedGroupingsReport] group count: 1 20:37:15.266 SERIAL » 0x01070080140000006c (9 bytes) 20:37:15.267 DRIVER » [Node 020] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 20:37:15.268 CNTRLR « [Node 021] supports 1 association groups 20:37:15.268 CNTRLR » [Node 021] querying association group #1... 20:37:15.269 SERIAL « [ACK] (0x06) 20:37:15.271 SERIAL « 0x012001803500f68b0000000000000000000000000000000000000000000000000 (34 bytes) 016 20:37:15.271 SERIAL » [ACK] (0x06) 20:37:15.271 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 5, 6, 18, 19, 21, 22, 23, 24, 25, 26, 28, 32 20:37:15.272 SERIAL » 0x0109001316028505253165 (11 bytes) 20:37:15.272 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 49 └─[AssociationCCSupportedGroupingsGet] 20:37:15.272 CNTRLR « [Node 020] node neighbors received: 1, 3, 5, 6, 18, 19, 21, 22, 23, 24, 25, 26, 28, 32 20:37:15.272 CNTRLR [Node 020] Interview stage completed: Neighbors 20:37:15.274 SERIAL « [ACK] (0x06) 20:37:15.275 CNTRLR [Node 020] Interview completed 20:37:15.275 CNTRLR [Node 020] The node is ready to be used 20:37:15.277 SERIAL « 0x0104011301e8 (6 bytes) 20:37:15.277 SERIAL » [ACK] (0x06) 20:37:15.277 DRIVER « [RES] [SendData] was sent: true 20:37:16.892 SERIAL « 0x01070013310000a278 (9 bytes) 20:37:16.893 SERIAL » [ACK] (0x06) 20:37:16.893 DRIVER « [REQ] [SendData] callback id: 49 transmit status: OK 20:37:17.039 SERIAL « 0x0109000400160385060165 (11 bytes) 20:37:17.040 CNTRLR [Node 022] [+] [Association] groupCount: 1 [Endpoint 0] [internal] 20:37:17.040 SERIAL » [ACK] (0x06) 20:37:17.041 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[AssociationCCSupportedGroupingsReport] group count: 1 20:37:17.044 SERIAL » 0x0109001317028505253267 (11 bytes) 20:37:17.044 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 50 └─[AssociationCCSupportedGroupingsGet] 20:37:17.044 CNTRLR « [Node 022] supports 1 association groups 20:37:17.044 CNTRLR » [Node 022] querying association group #1... 20:37:17.045 SERIAL « [ACK] (0x06) 20:37:17.049 SERIAL « 0x0104011301e8 (6 bytes) 20:37:17.050 SERIAL » [ACK] (0x06) 20:37:17.050 DRIVER « [RES] [SendData] was sent: true 20:37:18.475 SERIAL « 0x010700133200008f56 (9 bytes) 20:37:18.475 SERIAL » [ACK] (0x06) 20:37:18.476 DRIVER « [REQ] [SendData] callback id: 50 transmit status: OK 20:37:18.554 SERIAL « 0x0109000400170385060164 (11 bytes) 20:37:18.555 CNTRLR [Node 023] [+] [Association] groupCount: 1 [Endpoint 0] [internal] 20:37:18.555 SERIAL » [ACK] (0x06) 20:37:18.556 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[AssociationCCSupportedGroupingsReport] group count: 1 20:37:18.560 SERIAL » 0x0109001318028505253369 (11 bytes) 20:37:18.561 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 51 └─[AssociationCCSupportedGroupingsGet] 20:37:18.561 CNTRLR « [Node 023] supports 1 association groups 20:37:18.561 CNTRLR » [Node 023] querying association group #1... 20:37:18.567 SERIAL « [ACK] (0x06) 20:37:18.573 SERIAL « 0x0104011301e8 (6 bytes) 20:37:18.573 SERIAL » [ACK] (0x06) 20:37:18.574 DRIVER « [RES] [SendData] was sent: true 20:37:21.174 SERIAL « 0x0107001333000105dc (9 bytes) 20:37:21.175 SERIAL » [ACK] (0x06) 20:37:21.175 DRIVER « [REQ] [SendData] callback id: 51 transmit status: OK 20:37:21.315 SERIAL « 0x010c0004001c063105042202b34e (14 bytes) 20:37:21.317 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:37:21.317 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 56.2 => 69.1 [Endpoint 0] 20:37:21.318 SERIAL » [ACK] (0x06) 20:37:21.319 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 69.1 20:37:21.343 SERIAL « 0x010900040018038506016b (11 bytes) 20:37:21.344 CNTRLR [Node 024] [+] [Association] groupCount: 1 [Endpoint 0] [internal] 20:37:21.344 SERIAL » [ACK] (0x06) 20:37:21.345 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[AssociationCCSupportedGroupingsReport] group count: 1 20:37:21.347 SERIAL » 0x010900131a0232032534dd (11 bytes) 20:37:21.348 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 52 └─[MeterCCSupportedGet] 20:37:21.348 CNTRLR « [Node 024] supports 1 association groups 20:37:21.348 CNTRLR » [Node 024] querying association group #1... 20:37:21.351 SERIAL « [ACK] (0x06) 20:37:21.353 SERIAL « 0x0104011301e8 (6 bytes) 20:37:21.354 SERIAL » [ACK] (0x06) 20:37:21.355 DRIVER « [RES] [SendData] was sent: true 20:37:21.482 SERIAL « 0x010700133400000dd2 (9 bytes) 20:37:21.482 SERIAL » [ACK] (0x06) 20:37:21.483 DRIVER « [REQ] [SendData] callback id: 52 transmit status: OK 20:37:21.492 SERIAL « 0x010a0004001a04320481055d (12 bytes) 20:37:21.493 CNTRLR [Node 026] [+] [Meter] type: 1 [Endpoint 0] [internal] 20:37:21.493 CNTRLR [Node 026] [+] [Meter] supportsReset: true [Endpoint 0] [internal] 20:37:21.494 CNTRLR [Node 026] [+] [Meter] supportedScales: 0,2 [Endpoint 0] [internal] 20:37:21.494 CNTRLR [Node 026] [+] [Meter] supportedRateTypes: [Endpoint 0] [internal] 20:37:21.494 CNTRLR [Node 026] [Meter] reset: metadata updated [Endpoint 0] 20:37:21.495 SERIAL » [ACK] (0x06) 20:37:21.496 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MeterCCSupportedReport] type: Electric supports reset: true supported scales: · kWh · W supported rate types: 20:37:21.498 SERIAL » 0x010900131c0232032535da (11 bytes) 20:37:21.499 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 53 └─[MeterCCSupportedGet] 20:37:21.499 CNTRLR « [Node 026] received meter support: type: Electric supported scales: · kWh · W supported rate types: supports reset: true 20:37:21.499 CNTRLR » [Node 026] querying meter value (type = Electric, scale = kWh)... 20:37:21.502 SERIAL « [ACK] (0x06) 20:37:21.504 SERIAL « 0x0104011301e8 (6 bytes) 20:37:21.505 SERIAL » [ACK] (0x06) 20:37:21.505 DRIVER « [RES] [SendData] was sent: true 20:37:21.563 SERIAL « 0x0107001335000006d8 (9 bytes) 20:37:21.563 SERIAL » [ACK] (0x06) 20:37:21.564 DRIVER « [REQ] [SendData] callback id: 53 transmit status: OK 20:37:21.636 SERIAL « 0x010a0004001c04320481055b (12 bytes) 20:37:21.636 CNTRLR [Node 028] [+] [Meter] type: 1 [Endpoint 0] [internal] 20:37:21.637 CNTRLR [Node 028] [+] [Meter] supportsReset: true [Endpoint 0] [internal] 20:37:21.637 CNTRLR [Node 028] [+] [Meter] supportedScales: 0,2 [Endpoint 0] [internal] 20:37:21.637 CNTRLR [Node 028] [+] [Meter] supportedRateTypes: [Endpoint 0] [internal] 20:37:21.637 CNTRLR [Node 028] [Meter] reset: metadata updated [Endpoint 0] 20:37:21.637 SERIAL » [ACK] (0x06) 20:37:21.637 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MeterCCSupportedReport] type: Electric supports reset: true supported scales: · kWh · W supported rate types: 20:37:21.638 SERIAL » 0x01090013030231012536c7 (11 bytes) 20:37:21.639 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 54 └─[MultilevelSensorCCGetSupportedSensor] 20:37:21.639 CNTRLR « [Node 028] received meter support: type: Electric supported scales: · kWh · W supported rate types: supports reset: true 20:37:21.639 CNTRLR » [Node 028] querying meter value (type = Electric, scale = kWh)... 20:37:21.640 SERIAL « [ACK] (0x06) 20:37:21.644 SERIAL « 0x0104011301e8 (6 bytes) 20:37:21.644 SERIAL » [ACK] (0x06) 20:37:21.645 DRIVER « [RES] [SendData] was sent: true 20:37:21.728 SERIAL « 0x0107001336000008d5 (9 bytes) 20:37:21.729 SERIAL » [ACK] (0x06) 20:37:21.729 DRIVER « [REQ] [SendData] callback id: 54 transmit status: OK 20:37:21.740 SERIAL « 0x01090004000303310208c9 (11 bytes) 20:37:21.742 CNTRLR [Node 003] [+] [Multilevel Sensor] supportedSensorType [Endpoint 0] [internal] s: 4 20:37:21.742 SERIAL » [ACK] (0x06) 20:37:21.743 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedSensorReport] supported sensor types: · Power 20:37:21.746 SERIAL » 0x010a001313033201002537d7 (12 bytes) 20:37:21.746 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 55 └─[MeterCCGet] duration: kWh 20:37:21.747 CNTRLR « [Node 003] received supported sensor types: · Power 20:37:21.747 CNTRLR » [Node 003] querying supported scales for Power sensor 20:37:21.751 SERIAL « [ACK] (0x06) 20:37:21.752 SERIAL « 0x0104011301e8 (6 bytes) 20:37:21.752 SERIAL » [ACK] (0x06) 20:37:21.753 DRIVER « [RES] [SendData] was sent: true 20:37:21.898 SERIAL « 0x010700133700000fd3 (9 bytes) 20:37:21.898 SERIAL » [ACK] (0x06) 20:37:21.899 DRIVER « [REQ] [SendData] callback id: 55 transmit status: OK 20:37:21.943 SERIAL « 0x010c0004001c06310504220323df (14 bytes) 20:37:21.944 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:37:21.944 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 69.1 => 80.3 [Endpoint 0] 20:37:21.945 SERIAL » [ACK] (0x06) 20:37:21.946 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 80.3 20:37:22.038 SERIAL « 0x0110000400130a3202214400000425000086 (18 bytes) 20:37:22.039 CNTRLR [Node 019] [Meter] value[65537]: metadata updated [Endpoint 0] 20:37:22.040 CNTRLR [Node 019] [Meter] previousValue[65537]: metadata updated [Endpoint 0] 20:37:22.041 CNTRLR [Node 019] [Meter] deltaTime[65537]: metadata updated [Endpoint 0] 20:37:22.041 CNTRLR [Node 019] [+] [Meter] value[65537]: 10.61 [Endpoint 0] 20:37:22.042 CNTRLR [Node 019] [+] [Meter] deltaTime[65537]: 0 [Endpoint 0] 20:37:22.042 SERIAL » [ACK] (0x06) 20:37:22.043 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 10.61 time delta: 0 seconds 20:37:22.046 SERIAL » 0x010b00131204590300012538b7 (13 bytes) 20:37:22.046 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 56 └─[AssociationGroupInfoCCInfoGet] group id: 1 refresh cache: false 20:37:22.047 CNTRLR » [Node 019] querying meter value (type = Electric, scale = W)... 20:37:22.050 SERIAL « [ACK] (0x06) 20:37:22.052 SERIAL « 0x0104011301e8 (6 bytes) 20:37:22.053 SERIAL » [ACK] (0x06) 20:37:22.053 DRIVER « [RES] [SendData] was sent: true 20:37:22.174 SERIAL « 0x010700133800000dde (9 bytes) 20:37:22.174 SERIAL » [ACK] (0x06) 20:37:22.175 DRIVER « [REQ] [SendData] callback id: 56 transmit status: OK 20:37:22.185 SERIAL « 0x0110000400120a59040101000001000000af (18 bytes) 20:37:22.186 CNTRLR [Node 018] [+] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false 20:37:22.187 CNTRLR [Node 018] [+] [Association Group Information] info[1]: [object Obj [internal] ect] 20:37:22.187 SERIAL » [ACK] (0x06) 20:37:22.188 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #1 mode: 0 profile: 1 event code: 0 20:37:22.190 SERIAL » 0x010a0013150385020125396a (12 bytes) 20:37:22.191 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 57 └─[AssociationCCGet] group id: 1 20:37:22.191 CNTRLR « [Node 018] Received info for association group #1: info is dynamic: false profile: General: Lifeline 20:37:22.191 CNTRLR » [Node 018] Association group #1: Querying command list... 20:37:22.194 SERIAL « [ACK] (0x06) 20:37:22.196 SERIAL « 0x0104011301e8 (6 bytes) 20:37:22.196 SERIAL » [ACK] (0x06) 20:37:22.197 DRIVER « [RES] [SendData] was sent: true 20:37:23.564 SERIAL « 0x01070013390000895b (9 bytes) 20:37:23.564 SERIAL » [ACK] (0x06) 20:37:23.565 DRIVER « [REQ] [SendData] callback id: 57 transmit status: OK 20:37:23.649 SERIAL « 0x010c000400150685030101000163 (14 bytes) 20:37:23.649 SERIAL » [ACK] (0x06) 20:37:23.650 CNTRLR [Node 021] [+] [Association] maxNodes[1]: 1 [internal] 20:37:23.651 CNTRLR [Node 021] [+] [Association] nodeIds[1]: 1 [internal] 20:37:23.651 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 1 max # of nodes: 1 node IDs: 1 reports to follow: 0 20:37:23.656 SERIAL » 0x010a00131603850201253a6a (12 bytes) 20:37:23.656 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 58 └─[AssociationCCGet] group id: 1 20:37:23.657 CNTRLR « [Node 021] received information for association group #1: maximum # of nodes: 1 currently assigned nodes: 1 20:37:23.657 CNTRLR [Node 021] [+] [Association] hasLifeline: true [internal] 20:37:23.658 CNTRLR [Node 021] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 20:37:23.662 SERIAL « [ACK] (0x06) 20:37:23.664 SERIAL « 0x0104011301e8 (6 bytes) 20:37:23.664 SERIAL » [ACK] (0x06) 20:37:23.665 DRIVER « [RES] [SendData] was sent: true 20:37:23.666 CNTRLR [Node 021] AssociationGroupInfoCC: doing a complete interview... 20:37:23.666 CNTRLR » [Node 021] Association group #1: Querying name... 20:37:25.270 SERIAL « 0x010700133a0000a273 (9 bytes) 20:37:25.270 SERIAL » [ACK] (0x06) 20:37:25.271 DRIVER « [REQ] [SendData] callback id: 58 transmit status: OK 20:37:25.348 SERIAL « 0x010c000400160685030101000160 (14 bytes) 20:37:25.348 SERIAL » [ACK] (0x06) 20:37:25.349 CNTRLR [Node 022] [+] [Association] maxNodes[1]: 1 [internal] 20:37:25.349 CNTRLR [Node 022] [+] [Association] nodeIds[1]: 1 [internal] 20:37:25.350 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 1 max # of nodes: 1 node IDs: 1 reports to follow: 0 20:37:25.352 SERIAL » 0x010a00131703850201253b6a (12 bytes) 20:37:25.352 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 59 └─[AssociationCCGet] group id: 1 20:37:25.353 CNTRLR « [Node 022] received information for association group #1: maximum # of nodes: 1 currently assigned nodes: 1 20:37:25.353 CNTRLR [Node 022] [+] [Association] hasLifeline: true [internal] 20:37:25.353 CNTRLR [Node 022] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 20:37:25.355 SERIAL « [ACK] (0x06) 20:37:25.356 CNTRLR [Node 022] AssociationGroupInfoCC: doing a complete interview... 20:37:25.356 CNTRLR » [Node 022] Association group #1: Querying name... 20:37:25.358 SERIAL « 0x0104011301e8 (6 bytes) 20:37:25.358 SERIAL » [ACK] (0x06) 20:37:25.358 DRIVER « [RES] [SendData] was sent: true 20:37:26.821 SERIAL « 0x010700133b00009343 (9 bytes) 20:37:26.822 SERIAL » [ACK] (0x06) 20:37:26.822 DRIVER « [REQ] [SendData] callback id: 59 transmit status: OK 20:37:26.899 SERIAL « 0x010c000400170685030101000161 (14 bytes) 20:37:26.900 SERIAL » [ACK] (0x06) 20:37:26.901 CNTRLR [Node 023] [+] [Association] maxNodes[1]: 1 [internal] 20:37:26.901 CNTRLR [Node 023] [+] [Association] nodeIds[1]: 1 [internal] 20:37:26.902 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 1 max # of nodes: 1 node IDs: 1 reports to follow: 0 20:37:26.904 SERIAL » 0x010a00131803850201253c62 (12 bytes) 20:37:26.904 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 60 └─[AssociationCCGet] group id: 1 20:37:26.904 CNTRLR « [Node 023] received information for association group #1: maximum # of nodes: 1 currently assigned nodes: 1 20:37:26.904 CNTRLR [Node 023] [+] [Association] hasLifeline: true [internal] 20:37:26.905 CNTRLR [Node 023] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 20:37:26.906 SERIAL « [ACK] (0x06) 20:37:26.907 CNTRLR [Node 023] AssociationGroupInfoCC: doing a complete interview... 20:37:26.907 CNTRLR » [Node 023] Association group #1: Querying name... 20:37:26.910 SERIAL « 0x0104011301e8 (6 bytes) 20:37:26.910 SERIAL » [ACK] (0x06) 20:37:26.910 DRIVER « [RES] [SendData] was sent: true 20:37:28.354 SERIAL « 0x010700133c00009146 (9 bytes) 20:37:28.354 SERIAL » [ACK] (0x06) 20:37:28.355 DRIVER « [REQ] [SendData] callback id: 60 transmit status: OK 20:37:28.432 SERIAL « 0x010c00040018068503010100016e (14 bytes) 20:37:28.433 SERIAL » [ACK] (0x06) 20:37:28.434 CNTRLR [Node 024] [+] [Association] maxNodes[1]: 1 [internal] 20:37:28.434 CNTRLR [Node 024] [+] [Association] nodeIds[1]: 1 [internal] 20:37:28.434 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 1 max # of nodes: 1 node IDs: 1 reports to follow: 0 20:37:28.436 SERIAL » 0x010a00131a03320100253dd4 (12 bytes) 20:37:28.436 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 61 └─[MeterCCGet] duration: kWh 20:37:28.437 CNTRLR « [Node 024] received information for association group #1: maximum # of nodes: 1 currently assigned nodes: 1 20:37:28.437 CNTRLR [Node 024] [+] [Association] hasLifeline: true [internal] 20:37:28.437 CNTRLR [Node 024] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 20:37:28.439 SERIAL « [ACK] (0x06) 20:37:28.440 CNTRLR [Node 024] AssociationGroupInfoCC: doing a complete interview... 20:37:28.440 CNTRLR » [Node 024] Association group #1: Querying name... 20:37:28.442 SERIAL « 0x0104011301e8 (6 bytes) 20:37:28.442 SERIAL » [ACK] (0x06) 20:37:28.442 DRIVER « [RES] [SendData] was sent: true 20:37:28.524 SERIAL « 0x010700133d000009df (9 bytes) 20:37:28.524 SERIAL » [ACK] (0x06) 20:37:28.525 DRIVER « [REQ] [SendData] callback id: 61 transmit status: OK 20:37:28.535 SERIAL « 0x01100004001a0a32022144000035e3000078 (18 bytes) 20:37:28.536 CNTRLR [Node 026] [~] [Meter] value[65537]: 137.94 => 137.95 [Endpoint 0] 20:37:28.536 CNTRLR [Node 026] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 20:37:28.537 SERIAL » [ACK] (0x06) 20:37:28.540 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 137.95 time delta: 0 seconds 20:37:28.544 SERIAL » 0x010a00131c03320100253ed1 (12 bytes) 20:37:28.544 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 62 └─[MeterCCGet] duration: kWh 20:37:28.544 CNTRLR » [Node 026] querying meter value (type = Electric, scale = W)... 20:37:28.546 SERIAL « [ACK] (0x06) 20:37:28.549 SERIAL « 0x0104011301e8 (6 bytes) 20:37:28.550 SERIAL » [ACK] (0x06) 20:37:28.550 DRIVER « [RES] [SendData] was sent: true 20:37:28.609 SERIAL « 0x010700133e000006d3 (9 bytes) 20:37:28.609 SERIAL » [ACK] (0x06) 20:37:28.610 DRIVER « [REQ] [SendData] callback id: 62 transmit status: OK 20:37:28.688 SERIAL « 0x01100004001c0a32022144000013d9000062 (18 bytes) 20:37:28.689 CNTRLR [Node 028] [Meter] value[65537]: metadata updated [Endpoint 0] 20:37:28.690 CNTRLR [Node 028] [Meter] previousValue[65537]: metadata updated [Endpoint 0] 20:37:28.690 CNTRLR [Node 028] [Meter] deltaTime[65537]: metadata updated [Endpoint 0] 20:37:28.691 CNTRLR [Node 028] [+] [Meter] value[65537]: 50.81 [Endpoint 0] 20:37:28.691 CNTRLR [Node 028] [+] [Meter] deltaTime[65537]: 0 [Endpoint 0] 20:37:28.692 SERIAL » [ACK] (0x06) 20:37:28.693 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 50.81 time delta: 0 seconds 20:37:28.701 SERIAL » 0x010a00130303310304253fca (12 bytes) 20:37:28.702 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 63 └─[MultilevelSensorCCGetSupportedScale] sensor type: Power 20:37:28.702 CNTRLR » [Node 028] querying meter value (type = Electric, scale = W)... 20:37:28.706 SERIAL « [ACK] (0x06) 20:37:28.712 SERIAL « 0x0104011301e8 (6 bytes) 20:37:28.712 SERIAL » [ACK] (0x06) 20:37:28.713 DRIVER « [RES] [SendData] was sent: true 20:37:28.779 SERIAL « 0x010700133f000007d3 (9 bytes) 20:37:28.779 SERIAL » [ACK] (0x06) 20:37:28.779 DRIVER « [REQ] [SendData] callback id: 63 transmit status: OK 20:37:28.791 SERIAL « 0x010a000400030431060401c4 (12 bytes) 20:37:28.792 CNTRLR [Node 003] [+] [Multilevel Sensor] supportedScales[4]: [Endpoint 0] [internal] 0 20:37:28.792 SERIAL » [ACK] (0x06) 20:37:28.793 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedScaleReport] sensor type: Power supported scales: · Watt 20:37:28.794 SERIAL » 0x010a001313033201102540b0 (12 bytes) 20:37:28.795 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 64 └─[MeterCCGet] duration: W 20:37:28.795 CNTRLR « [Node 003] received supported scales: · Watt 20:37:28.795 CNTRLR » [Node 003] querying Power sensor reading... 20:37:28.797 SERIAL « [ACK] (0x06) 20:37:28.800 SERIAL « 0x0104011301e8 (6 bytes) 20:37:28.801 SERIAL » [ACK] (0x06) 20:37:28.801 DRIVER « [RES] [SendData] was sent: true 20:37:28.942 SERIAL « 0x010700134000000fa4 (9 bytes) 20:37:28.942 SERIAL » [ACK] (0x06) 20:37:28.942 DRIVER « [REQ] [SendData] callback id: 64 transmit status: OK 20:37:29.071 SERIAL « 0x010e00040013083202213200000000cd (16 bytes) 20:37:29.072 CNTRLR [Node 019] [Meter] value[66049]: metadata updated [Endpoint 0] 20:37:29.073 CNTRLR [Node 019] [Meter] previousValue[66049]: metadata updated [Endpoint 0] 20:37:29.073 CNTRLR [Node 019] [Meter] deltaTime[66049]: metadata updated [Endpoint 0] 20:37:29.074 CNTRLR [Node 019] [+] [Meter] value[66049]: 0 [Endpoint 0] 20:37:29.074 CNTRLR [Node 019] [+] [Meter] deltaTime[66049]: 0 [Endpoint 0] 20:37:29.075 SERIAL » [ACK] (0x06) 20:37:29.076 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:37:29.078 SERIAL » 0x010b0013120459058001254148 (13 bytes) 20:37:29.079 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 65 └─[AssociationGroupInfoCCCommandListGet] group id: 1 allow cache: true 20:37:29.079 CNTRLR [Node 019] [+] [Meter] interviewComplete: true [Endpoint 0] [internal] 20:37:29.085 SERIAL « [ACK] (0x06) 20:37:29.086 SERIAL « 0x0104011301e8 (6 bytes) 20:37:29.086 SERIAL » [ACK] (0x06) 20:37:29.087 DRIVER « [RES] [SendData] was sent: true 20:37:29.089 CNTRLR [Node 019] MultilevelSensorCC: doing a complete interview... 20:37:29.089 CNTRLR » [Node 019] retrieving supported sensor types... 20:37:29.204 SERIAL « 0x010700134100000ca6 (9 bytes) 20:37:29.205 SERIAL » [ACK] (0x06) 20:37:29.205 DRIVER « [REQ] [SendData] callback id: 65 transmit status: OK 20:37:29.215 SERIAL « 0x0112000400120c590601087105320225035a0198 (20 bytes) 20:37:29.216 CNTRLR [Node 018] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[1]: [object Map] 20:37:29.217 SERIAL » [ACK] (0x06) 20:37:29.217 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 1 commands: · Notification: 0x05 · Meter: 0x02 · Binary Switch: 0x03 · Device Reset Locally: 0x01 20:37:29.221 SERIAL » 0x010a001315035901012542ce (12 bytes) 20:37:29.221 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 66 └─[AssociationGroupInfoCCNameGet] group id: 1 20:37:29.222 CNTRLR [Node 018] [+] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true 20:37:29.222 CNTRLR [Node 018] NotificationCC: doing a complete interview... 20:37:29.222 CNTRLR [Node 018] [+] [Notification] interviewComplete: true [Endpoint 0] [internal] 20:37:29.223 CNTRLR [Node 018] Interview stage completed: CommandClasses 20:37:29.223 CNTRLR [Node 018] Interview stage completed: OverwriteConfig 20:37:29.223 CNTRLR » [Node 018] requesting node neighbors... 20:37:29.225 SERIAL « [ACK] (0x06) 20:37:29.227 SERIAL « 0x0104011301e8 (6 bytes) 20:37:29.227 SERIAL » [ACK] (0x06) 20:37:29.228 DRIVER « [RES] [SendData] was sent: true 20:37:30.628 SERIAL « 0x010700134200008c25 (9 bytes) 20:37:30.629 SERIAL » [ACK] (0x06) 20:37:30.629 DRIVER « [REQ] [SendData] callback id: 66 transmit status: OK 20:37:30.714 SERIAL « 0x0112000400150c590201084c6966656c696e658a (20 bytes) 20:37:30.715 CNTRLR [Node 021] [+] [Association Group Information] name[1]: "Lifeline" [internal] 20:37:30.716 SERIAL » [ACK] (0x06) 20:37:30.716 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 1 name: Lifeline 20:37:30.719 SERIAL » 0x01070080120000006a (9 bytes) 20:37:30.720 DRIVER » [Node 018] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 20:37:30.720 CNTRLR « [Node 021] Association group #1 has name "Lifeline" 20:37:30.720 CNTRLR » [Node 021] Association group #1: Querying info... 20:37:30.723 SERIAL « [ACK] (0x06) 20:37:30.724 SERIAL « 0x012001803700fc8b0000000000000000000000000000000000000000000000000 (34 bytes) 01e 20:37:30.724 SERIAL » [ACK] (0x06) 20:37:30.725 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 2, 3, 5, 6, 19, 20, 21, 22, 23, 24, 25, 26, 28, 32 20:37:30.729 SERIAL » 0x010a001316035901012543cc (12 bytes) 20:37:30.730 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 67 └─[AssociationGroupInfoCCNameGet] group id: 1 20:37:30.730 CNTRLR « [Node 018] node neighbors received: 1, 2, 3, 5, 6, 19, 20, 21, 22, 23, 24, 2 5, 26, 28, 32 20:37:30.730 CNTRLR [Node 018] Interview stage completed: Neighbors 20:37:30.735 SERIAL « [ACK] (0x06) 20:37:30.736 SERIAL « 0x0104011301e8 (6 bytes) 20:37:30.737 SERIAL » [ACK] (0x06) 20:37:30.737 DRIVER « [RES] [SendData] was sent: true 20:37:30.739 CNTRLR [Node 018] Interview completed 20:37:30.739 CNTRLR [Node 018] The node is ready to be used 20:37:32.376 SERIAL « 0x01070013430000a40c (9 bytes) 20:37:32.376 SERIAL » [ACK] (0x06) 20:37:32.377 DRIVER « [REQ] [SendData] callback id: 67 transmit status: OK 20:37:32.460 SERIAL « 0x0112000400160c590201084c6966656c696e6589 (20 bytes) 20:37:32.461 CNTRLR [Node 022] [+] [Association Group Information] name[1]: "Lifeline" [internal] 20:37:32.461 SERIAL » [ACK] (0x06) 20:37:32.461 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 1 name: Lifeline 20:37:32.464 SERIAL » 0x010a001317035901012544ca (12 bytes) 20:37:32.465 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 68 └─[AssociationGroupInfoCCNameGet] group id: 1 20:37:32.465 CNTRLR « [Node 022] Association group #1 has name "Lifeline" 20:37:32.465 CNTRLR » [Node 022] Association group #1: Querying info... 20:37:32.467 SERIAL « [ACK] (0x06) 20:37:32.471 SERIAL « 0x0104011301e8 (6 bytes) 20:37:32.471 SERIAL » [ACK] (0x06) 20:37:32.472 DRIVER « [RES] [SendData] was sent: true 20:37:33.913 SERIAL « 0x01070013440000913e (9 bytes) 20:37:33.914 SERIAL » [ACK] (0x06) 20:37:33.914 DRIVER « [REQ] [SendData] callback id: 68 transmit status: OK 20:37:33.998 SERIAL « 0x0112000400170c590201084c6966656c696e6588 (20 bytes) 20:37:33.999 CNTRLR [Node 023] [+] [Association Group Information] name[1]: "Lifeline" [internal] 20:37:33.999 SERIAL » [ACK] (0x06) 20:37:34.000 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 1 name: Lifeline 20:37:34.003 SERIAL » 0x010a001318035901012545c4 (12 bytes) 20:37:34.003 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 69 └─[AssociationGroupInfoCCNameGet] group id: 1 20:37:34.003 CNTRLR « [Node 023] Association group #1 has name "Lifeline" 20:37:34.003 CNTRLR » [Node 023] Association group #1: Querying info... 20:37:34.005 SERIAL « [ACK] (0x06) 20:37:34.009 SERIAL « 0x0104011301e8 (6 bytes) 20:37:34.009 SERIAL » [ACK] (0x06) 20:37:34.010 DRIVER « [RES] [SendData] was sent: true 20:37:35.436 SERIAL « 0x010700134500008f21 (9 bytes) 20:37:35.436 SERIAL » [ACK] (0x06) 20:37:35.437 DRIVER « [REQ] [SendData] callback id: 69 transmit status: OK 20:37:35.523 SERIAL « 0x0112000400180c590201084c6966656c696e6587 (20 bytes) 20:37:35.524 CNTRLR [Node 024] [+] [Association Group Information] name[1]: "Lifeline" [internal] 20:37:35.524 SERIAL » [ACK] (0x06) 20:37:35.524 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 1 name: Lifeline 20:37:35.527 SERIAL » 0x010a00131a033201102546bf (12 bytes) 20:37:35.527 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 70 └─[MeterCCGet] duration: W 20:37:35.528 CNTRLR « [Node 024] Association group #1 has name "Lifeline" 20:37:35.528 CNTRLR » [Node 024] Association group #1: Querying info... 20:37:35.530 SERIAL « [ACK] (0x06) 20:37:35.533 SERIAL « 0x0104011301e8 (6 bytes) 20:37:35.534 SERIAL » [ACK] (0x06) 20:37:35.534 DRIVER « [RES] [SendData] was sent: true 20:37:35.614 SERIAL « 0x0107001346000008a5 (9 bytes) 20:37:35.614 SERIAL » [ACK] (0x06) 20:37:35.615 DRIVER « [REQ] [SendData] callback id: 70 transmit status: OK 20:37:35.624 SERIAL « 0x010e0004001a0832022132099700005a (16 bytes) 20:37:35.625 CNTRLR [Node 026] [Meter] value[66049]: metadata updated [Endpoint 0] 20:37:35.626 CNTRLR [Node 026] [Meter] previousValue[66049]: metadata updated [Endpoint 0] 20:37:35.627 CNTRLR [Node 026] [Meter] deltaTime[66049]: metadata updated [Endpoint 0] 20:37:35.627 CNTRLR [Node 026] [+] [Meter] value[66049]: 245.5 [Endpoint 0] 20:37:35.628 CNTRLR [Node 026] [+] [Meter] deltaTime[66049]: 0 [Endpoint 0] 20:37:35.628 SERIAL » [ACK] (0x06) 20:37:35.629 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 245.5 time delta: 0 seconds 20:37:35.630 SERIAL » 0x010a00131c033201102547b8 (12 bytes) 20:37:35.630 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 71 └─[MeterCCGet] duration: W 20:37:35.631 CNTRLR [Node 026] [+] [Meter] interviewComplete: true [Endpoint 0] [internal] 20:37:35.633 SERIAL « [ACK] (0x06) 20:37:35.634 CNTRLR [Node 026] MultilevelSensorCC: doing a complete interview... 20:37:35.634 CNTRLR » [Node 026] retrieving supported sensor types... 20:37:35.635 SERIAL « 0x0104011301e8 (6 bytes) 20:37:35.635 SERIAL » [ACK] (0x06) 20:37:35.635 DRIVER « [RES] [SendData] was sent: true 20:37:35.694 SERIAL « 0x0107001347000006aa (9 bytes) 20:37:35.695 SERIAL » [ACK] (0x06) 20:37:35.695 DRIVER « [REQ] [SendData] callback id: 71 transmit status: OK 20:37:35.768 SERIAL « 0x010e0004001c083202213203140000d5 (16 bytes) 20:37:35.769 CNTRLR [Node 028] [Meter] value[66049]: metadata updated [Endpoint 0] 20:37:35.770 CNTRLR [Node 028] [Meter] previousValue[66049]: metadata updated [Endpoint 0] 20:37:35.770 CNTRLR [Node 028] [Meter] deltaTime[66049]: metadata updated [Endpoint 0] 20:37:35.774 CNTRLR [Node 028] [+] [Meter] value[66049]: 78.8 [Endpoint 0] 20:37:35.776 CNTRLR [Node 028] [+] [Meter] deltaTime[66049]: 0 [Endpoint 0] 20:37:35.776 SERIAL » [ACK] (0x06) 20:37:35.778 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 78.8 time delta: 0 seconds 20:37:35.782 SERIAL » 0x010b00130304310404002548bc (13 bytes) 20:37:35.783 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 72 └─[MultilevelSensorCCGet] sensor type: Power scale: Watt 20:37:35.784 CNTRLR [Node 028] [+] [Meter] interviewComplete: true [Endpoint 0] [internal] 20:37:35.791 SERIAL « [ACK] (0x06) 20:37:35.793 SERIAL « 0x0104011301e8 (6 bytes) 20:37:35.794 SERIAL » [ACK] (0x06) 20:37:35.794 DRIVER « [RES] [SendData] was sent: true 20:37:35.796 CNTRLR [Node 028] MultilevelSensorCC: doing a complete interview... 20:37:35.796 CNTRLR » [Node 028] retrieving supported sensor types... 20:37:35.860 SERIAL « 0x0107001348000007a4 (9 bytes) 20:37:35.860 SERIAL » [ACK] (0x06) 20:37:35.861 DRIVER « [REQ] [SendData] callback id: 72 transmit status: OK 20:37:35.872 SERIAL « 0x010c0004000306310504220000e0 (14 bytes) 20:37:35.872 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:37:35.872 CNTRLR [Node 003] [+] [Multilevel Sensor] Power: 0 [Endpoint 0] 20:37:35.872 SERIAL » [ACK] (0x06) 20:37:35.873 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 20:37:35.874 SERIAL » 0x01090013130231012549a8 (11 bytes) 20:37:35.874 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 73 └─[MultilevelSensorCCGetSupportedSensor] 20:37:35.874 CNTRLR « [Node 003] received current Power sensor reading: 0 W 20:37:35.874 CNTRLR [Node 003] [+] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true 20:37:35.875 CNTRLR [Node 003] AssociationCC: doing a complete interview... 20:37:35.875 CNTRLR » [Node 003] querying number of association groups... 20:37:35.876 SERIAL « [ACK] (0x06) 20:37:35.879 SERIAL « 0x0104011301e8 (6 bytes) 20:37:35.880 SERIAL » [ACK] (0x06) 20:37:35.880 DRIVER « [RES] [SendData] was sent: true 20:37:36.021 SERIAL « 0x010700134900000fad (9 bytes) 20:37:36.021 SERIAL » [ACK] (0x06) 20:37:36.022 DRIVER « [REQ] [SendData] callback id: 73 transmit status: OK 20:37:36.143 SERIAL « 0x01090004001303310208d9 (11 bytes) 20:37:36.144 CNTRLR [Node 019] [+] [Multilevel Sensor] supportedSensorType [Endpoint 0] [internal] s: 4 20:37:36.144 SERIAL » [ACK] (0x06) 20:37:36.145 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedSensorReport] supported sensor types: · Power 20:37:36.148 SERIAL » 0x010b0013150459030001254ac2 (13 bytes) 20:37:36.148 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 74 └─[AssociationGroupInfoCCInfoGet] group id: 1 refresh cache: false 20:37:36.148 CNTRLR « [Node 019] received supported sensor types: · Power 20:37:36.148 CNTRLR » [Node 019] querying supported scales for Power sensor 20:37:36.151 SERIAL « [ACK] (0x06) 20:37:36.153 SERIAL « 0x0104011301e8 (6 bytes) 20:37:36.154 SERIAL » [ACK] (0x06) 20:37:36.154 DRIVER « [RES] [SendData] was sent: true 20:37:37.644 SERIAL « 0x010700134a00009534 (9 bytes) 20:37:37.645 SERIAL » [ACK] (0x06) 20:37:37.645 DRIVER « [REQ] [SendData] callback id: 74 transmit status: OK 20:37:37.725 SERIAL « 0x0110000400150a59040101000001000000a8 (18 bytes) 20:37:37.726 CNTRLR [Node 021] [+] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false 20:37:37.727 CNTRLR [Node 021] [+] [Association Group Information] info[1]: [object Obj [internal] ect] 20:37:37.727 SERIAL » [ACK] (0x06) 20:37:37.728 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #1 mode: 0 profile: 1 event code: 0 20:37:37.730 SERIAL » 0x010b0013160459030001254bc0 (13 bytes) 20:37:37.730 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 75 └─[AssociationGroupInfoCCInfoGet] group id: 1 refresh cache: false 20:37:37.730 CNTRLR « [Node 021] Received info for association group #1: info is dynamic: false profile: General: Lifeline 20:37:37.730 CNTRLR » [Node 021] Association group #1: Querying command list... 20:37:37.731 SERIAL « [ACK] (0x06) 20:37:37.736 SERIAL « 0x0104011301e8 (6 bytes) 20:37:37.736 SERIAL » [ACK] (0x06) 20:37:37.737 DRIVER « [RES] [SendData] was sent: true 20:37:39.408 SERIAL « 0x010700134b0000a707 (9 bytes) 20:37:39.408 SERIAL » [ACK] (0x06) 20:37:39.409 DRIVER « [REQ] [SendData] callback id: 75 transmit status: OK 20:37:39.493 SERIAL « 0x0110000400160a59040101000001000000ab (18 bytes) 20:37:39.494 CNTRLR [Node 022] [+] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false 20:37:39.495 CNTRLR [Node 022] [+] [Association Group Information] info[1]: [object Obj [internal] ect] 20:37:39.495 SERIAL » [ACK] (0x06) 20:37:39.496 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #1 mode: 0 profile: 1 event code: 0 20:37:39.498 SERIAL » 0x010b0013170459030001254cc6 (13 bytes) 20:37:39.498 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 76 └─[AssociationGroupInfoCCInfoGet] group id: 1 refresh cache: false 20:37:39.498 CNTRLR « [Node 022] Received info for association group #1: info is dynamic: false profile: General: Lifeline 20:37:39.498 CNTRLR » [Node 022] Association group #1: Querying command list... 20:37:39.499 SERIAL « [ACK] (0x06) 20:37:39.503 SERIAL « 0x0104011301e8 (6 bytes) 20:37:39.504 SERIAL » [ACK] (0x06) 20:37:39.504 DRIVER « [RES] [SendData] was sent: true 20:37:40.940 SERIAL « 0x010700134c00009037 (9 bytes) 20:37:40.941 SERIAL » [ACK] (0x06) 20:37:40.941 DRIVER « [REQ] [SendData] callback id: 76 transmit status: OK 20:37:41.024 SERIAL « 0x010c0004001c063105042202a558 (14 bytes) 20:37:41.024 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:37:41.025 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 80.3 => 67.7 [Endpoint 0] 20:37:41.025 SERIAL » [ACK] (0x06) 20:37:41.026 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 67.7 20:37:41.150 SERIAL « 0x010c0004001c063105042202a558 (14 bytes) 20:37:41.151 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:37:41.152 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 67.7 => 67.7 [Endpoint 0] 20:37:41.152 SERIAL » [ACK] (0x06) 20:37:41.153 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 67.7 20:37:41.196 SERIAL « 0x0110000400170a59040101000001000000aa (18 bytes) 20:37:41.197 CNTRLR [Node 023] [+] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false 20:37:41.197 CNTRLR [Node 023] [+] [Association Group Information] info[1]: [object Obj [internal] ect] 20:37:41.198 SERIAL » [ACK] (0x06) 20:37:41.198 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #1 mode: 0 profile: 1 event code: 0 20:37:41.201 SERIAL » 0x010b0013180459030001254dc8 (13 bytes) 20:37:41.201 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 77 └─[AssociationGroupInfoCCInfoGet] group id: 1 refresh cache: false 20:37:41.202 CNTRLR « [Node 023] Received info for association group #1: info is dynamic: false profile: General: Lifeline 20:37:41.202 CNTRLR » [Node 023] Association group #1: Querying command list... 20:37:41.204 SERIAL « [ACK] (0x06) 20:37:41.207 SERIAL « 0x0104011301e8 (6 bytes) 20:37:41.208 SERIAL » [ACK] (0x06) 20:37:41.208 DRIVER « [RES] [SendData] was sent: true 20:37:42.668 SERIAL « 0x010700134d00009234 (9 bytes) 20:37:42.669 SERIAL » [ACK] (0x06) 20:37:42.669 DRIVER « [REQ] [SendData] callback id: 77 transmit status: OK 20:37:42.751 SERIAL « 0x0110000400180a59040101000001000000a5 (18 bytes) 20:37:42.753 CNTRLR [Node 024] [+] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false 20:37:42.753 CNTRLR [Node 024] [+] [Association Group Information] info[1]: [object Obj [internal] ect] 20:37:42.753 SERIAL » [ACK] (0x06) 20:37:42.754 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #1 mode: 0 profile: 1 event code: 0 20:37:42.758 SERIAL » 0x010900131a023101254ea6 (11 bytes) 20:37:42.758 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 78 └─[MultilevelSensorCCGetSupportedSensor] 20:37:42.759 CNTRLR « [Node 024] Received info for association group #1: info is dynamic: false profile: General: Lifeline 20:37:42.759 CNTRLR » [Node 024] Association group #1: Querying command list... 20:37:42.766 SERIAL « [ACK] (0x06) 20:37:42.770 SERIAL « 0x0104011301e8 (6 bytes) 20:37:42.771 SERIAL » [ACK] (0x06) 20:37:42.772 DRIVER « [RES] [SendData] was sent: true 20:37:42.834 SERIAL « 0x010700134e000007a2 (9 bytes) 20:37:42.835 SERIAL » [ACK] (0x06) 20:37:42.835 DRIVER « [REQ] [SendData] callback id: 78 transmit status: OK 20:37:42.844 SERIAL « 0x01090004001a03310208d0 (11 bytes) 20:37:42.845 CNTRLR [Node 026] [+] [Multilevel Sensor] supportedSensorType [Endpoint 0] [internal] s: 4 20:37:42.845 SERIAL » [ACK] (0x06) 20:37:42.846 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedSensorReport] supported sensor types: · Power 20:37:42.850 SERIAL » 0x010900131c023101254fa1 (11 bytes) 20:37:42.850 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 79 └─[MultilevelSensorCCGetSupportedSensor] 20:37:42.850 CNTRLR « [Node 026] received supported sensor types: · Power 20:37:42.851 CNTRLR » [Node 026] querying supported scales for Power sensor 20:37:42.856 SERIAL « [ACK] (0x06) 20:37:42.857 SERIAL « 0x0104011301e8 (6 bytes) 20:37:42.857 SERIAL » [ACK] (0x06) 20:37:42.858 DRIVER « [RES] [SendData] was sent: true 20:37:42.914 SERIAL « 0x010700134f000006a2 (9 bytes) 20:37:42.915 SERIAL » [ACK] (0x06) 20:37:42.915 DRIVER « [REQ] [SendData] callback id: 79 transmit status: OK 20:37:42.986 SERIAL « 0x01090004001c03310208d6 (11 bytes) 20:37:42.987 CNTRLR [Node 028] [+] [Multilevel Sensor] supportedSensorType [Endpoint 0] [internal] s: 4 20:37:42.987 SERIAL » [ACK] (0x06) 20:37:42.988 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedSensorReport] supported sensor types: · Power 20:37:42.993 SERIAL » 0x0109001303028505255011 (11 bytes) 20:37:42.994 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 80 └─[AssociationCCSupportedGroupingsGet] 20:37:42.994 CNTRLR « [Node 028] received supported sensor types: · Power 20:37:42.994 CNTRLR » [Node 028] querying supported scales for Power sensor 20:37:42.997 SERIAL « [ACK] (0x06) 20:37:42.999 SERIAL « 0x0104011301e8 (6 bytes) 20:37:42.999 SERIAL » [ACK] (0x06) 20:37:43.000 DRIVER « [RES] [SendData] was sent: true 20:37:43.078 SERIAL « 0x0107001350000008b3 (9 bytes) 20:37:43.079 SERIAL » [ACK] (0x06) 20:37:43.080 DRIVER « [REQ] [SendData] callback id: 80 transmit status: OK 20:37:43.090 SERIAL « 0x0109000400030385060372 (11 bytes) 20:37:43.092 CNTRLR [Node 003] [+] [Association] groupCount: 3 [Endpoint 0] [internal] 20:37:43.093 SERIAL » [ACK] (0x06) 20:37:43.094 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[AssociationCCSupportedGroupingsReport] group count: 3 20:37:43.098 SERIAL » 0x010a001313033103042551b4 (12 bytes) 20:37:43.099 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 81 └─[MultilevelSensorCCGetSupportedScale] sensor type: Power 20:37:43.099 CNTRLR « [Node 003] supports 3 association groups 20:37:43.099 CNTRLR [Node 003] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 20:37:43.100 CNTRLR [Node 003] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 20:37:43.105 SERIAL « [ACK] (0x06) 20:37:43.108 SERIAL « 0x0104011301e8 (6 bytes) 20:37:43.108 SERIAL » [ACK] (0x06) 20:37:43.109 DRIVER « [RES] [SendData] was sent: true 20:37:43.112 CNTRLR [Node 003] MultiChannelAssociationCC: doing a complete interview... 20:37:43.112 CNTRLR » [Node 003] querying number of multi channel association groups... 20:37:43.246 SERIAL « 0x010700135100000eb4 (9 bytes) 20:37:43.247 SERIAL » [ACK] (0x06) 20:37:43.248 DRIVER « [REQ] [SendData] callback id: 81 transmit status: OK 20:37:43.348 SERIAL « 0x010a000400130431060401d4 (12 bytes) 20:37:43.349 CNTRLR [Node 019] [+] [Multilevel Sensor] supportedScales[4]: [Endpoint 0] [internal] 0 20:37:43.353 SERIAL » [ACK] (0x06) 20:37:43.354 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedScaleReport] sensor type: Power supported scales: · Watt 20:37:43.358 SERIAL » 0x0109001303028e05255218 (11 bytes) 20:37:43.358 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 82 └─[MultiChannelAssociationCCSupportedGroupingsGet] 20:37:43.359 CNTRLR « [Node 019] received supported scales: · Watt 20:37:43.359 CNTRLR » [Node 019] querying Power sensor reading... 20:37:43.364 SERIAL « [ACK] (0x06) 20:37:43.365 SERIAL « 0x0104011301e8 (6 bytes) 20:37:43.366 SERIAL » [ACK] (0x06) 20:37:43.366 DRIVER « [RES] [SendData] was sent: true 20:37:43.478 SERIAL « 0x010700135200000bb2 (9 bytes) 20:37:43.479 SERIAL » [ACK] (0x06) 20:37:43.480 DRIVER « [REQ] [SendData] callback id: 82 transmit status: OK 20:37:43.490 SERIAL « 0x010900040003038e060379 (11 bytes) 20:37:43.492 CNTRLR [Node 003] [+] [Multi Channel Association] groupCount: [Endpoint 0] [internal] 3 20:37:43.492 SERIAL » [ACK] (0x06) 20:37:43.493 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCSupportedGroupingsReport] group count: 3 20:37:43.498 SERIAL » 0x010b001315045905800125535d (13 bytes) 20:37:43.498 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 83 └─[AssociationGroupInfoCCCommandListGet] group id: 1 allow cache: true 20:37:43.499 CNTRLR « [Node 003] supports 3 multi channel association groups 20:37:43.499 CNTRLR » [Node 003] querying multi channel association group #1... 20:37:43.503 SERIAL « [ACK] (0x06) 20:37:43.505 SERIAL « 0x0104011301e8 (6 bytes) 20:37:43.505 SERIAL » [ACK] (0x06) 20:37:43.506 DRIVER « [RES] [SendData] was sent: true 20:37:44.942 SERIAL « 0x010700135300009028 (9 bytes) 20:37:44.942 SERIAL » [ACK] (0x06) 20:37:44.943 DRIVER « [REQ] [SendData] callback id: 83 transmit status: OK 20:37:45.033 SERIAL « 0x011a00040015145906011080035a0140034303710575032603310566 (28 bytes) 20:37:45.034 CNTRLR [Node 021] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[1]: [object Map] 20:37:45.034 SERIAL » [ACK] (0x06) 20:37:45.035 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 1 commands: · Battery: 0x03 · Device Reset Locally: 0x01 · Thermostat Mode: 0x03 · Thermostat Setpoint: 0x03 · Notification: 0x05 · Protection: 0x03 · Multilevel Switch: 0x03 · Multilevel Sensor: 0x05 20:37:45.038 SERIAL » 0x010a001303038e020125541a (12 bytes) 20:37:45.038 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 84 └─[MultiChannelAssociationCCGet] group id: 1 20:37:45.039 CNTRLR [Node 021] [+] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true 20:37:45.041 SERIAL « [ACK] (0x06) 20:37:45.043 CNTRLR [Node 021] NotificationCC: doing a complete interview... 20:37:45.043 CNTRLR » [Node 021] querying supported notification types... 20:37:45.065 SERIAL « 0x0104011301e8 (6 bytes) 20:37:45.065 SERIAL » [ACK] (0x06) 20:37:45.066 DRIVER « [RES] [SendData] was sent: true 20:37:45.129 SERIAL « 0x0107001354000008b7 (9 bytes) 20:37:45.129 SERIAL » [ACK] (0x06) 20:37:45.130 DRIVER « [REQ] [SendData] callback id: 84 transmit status: OK 20:37:45.142 SERIAL « 0x010e00040003088e0301010000010072 (16 bytes) 20:37:45.143 SERIAL » [ACK] (0x06) 20:37:45.145 CNTRLR [Node 003] [+] [Multi Channel Association] maxNodes[1]: 1 20:37:45.149 CNTRLR [Node 003] [+] [Multi Channel Association] nodeIds[1]: 20:37:45.150 CNTRLR [Node 003] [+] [Multi Channel Association] endpoints[1]: [object Object] 20:37:45.151 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 1 node ids: endpoints: 1:0 20:37:45.155 SERIAL » 0x010b0013160459058001255558 (13 bytes) 20:37:45.155 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 85 └─[AssociationGroupInfoCCCommandListGet] group id: 1 allow cache: true 20:37:45.156 CNTRLR « [Node 003] received information for multi channel association group #1: maximum # of nodes: 1 currently assigned nodes: currently assigned endpoints: 1:0 20:37:45.156 CNTRLR » [Node 003] querying multi channel association group #2... 20:37:45.159 SERIAL « [ACK] (0x06) 20:37:45.161 SERIAL « 0x0104011301e8 (6 bytes) 20:37:45.162 SERIAL » [ACK] (0x06) 20:37:45.163 DRIVER « [RES] [SendData] was sent: true 20:37:46.753 SERIAL « 0x01070013550000a01e (9 bytes) 20:37:46.754 SERIAL » [ACK] (0x06) 20:37:46.754 DRIVER « [REQ] [SendData] callback id: 85 transmit status: OK 20:37:46.922 SERIAL « 0x011a00040016145906011080035a0140034303710575032603310565 (28 bytes) 20:37:46.922 CNTRLR [Node 022] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[1]: [object Map] 20:37:46.923 SERIAL » [ACK] (0x06) 20:37:46.923 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 1 commands: · Battery: 0x03 · Device Reset Locally: 0x01 · Thermostat Mode: 0x03 · Thermostat Setpoint: 0x03 · Notification: 0x05 · Protection: 0x03 · Multilevel Switch: 0x03 · Multilevel Sensor: 0x05 20:37:46.926 SERIAL » 0x010a001303038e020225561b (12 bytes) 20:37:46.927 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 86 └─[MultiChannelAssociationCCGet] group id: 2 20:37:46.927 CNTRLR [Node 022] [+] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true 20:37:46.932 SERIAL « [ACK] (0x06) 20:37:46.933 SERIAL « 0x0104011301e8 (6 bytes) 20:37:46.934 SERIAL » [ACK] (0x06) 20:37:46.934 DRIVER « [RES] [SendData] was sent: true 20:37:46.936 CNTRLR [Node 022] NotificationCC: doing a complete interview... 20:37:46.936 CNTRLR » [Node 022] querying supported notification types... 20:37:47.008 SERIAL « 0x0107001356000008b5 (9 bytes) 20:37:47.009 SERIAL » [ACK] (0x06) 20:37:47.009 DRIVER « [REQ] [SendData] callback id: 86 transmit status: OK 20:37:47.021 SERIAL « 0x010b00040003058e03020a0073 (13 bytes) 20:37:47.022 SERIAL » [ACK] (0x06) 20:37:47.022 CNTRLR [Node 003] [+] [Multi Channel Association] maxNodes[2]: 10 20:37:47.023 CNTRLR [Node 003] [+] [Multi Channel Association] nodeIds[2]: 20:37:47.024 CNTRLR [Node 003] [+] [Multi Channel Association] endpoints[2]: 20:37:47.027 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 10 node ids: endpoints: 20:37:47.030 SERIAL » 0x010b001317045905800125575b (13 bytes) 20:37:47.030 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 87 └─[AssociationGroupInfoCCCommandListGet] group id: 1 allow cache: true 20:37:47.031 CNTRLR « [Node 003] received information for multi channel association group #2: maximum # of nodes: 10 currently assigned nodes: currently assigned endpoints: 20:37:47.031 CNTRLR » [Node 003] querying multi channel association group #3... 20:37:47.034 SERIAL « [ACK] (0x06) 20:37:47.036 SERIAL « 0x0104011301e8 (6 bytes) 20:37:47.036 SERIAL » [ACK] (0x06) 20:37:47.037 DRIVER « [RES] [SendData] was sent: true 20:37:48.439 SERIAL « 0x010700135700008c30 (9 bytes) 20:37:48.440 SERIAL » [ACK] (0x06) 20:37:48.440 DRIVER « [REQ] [SendData] callback id: 87 transmit status: OK 20:37:48.527 SERIAL « 0x011a00040017145906011080035a0140034303710575032603310564 (28 bytes) 20:37:48.527 CNTRLR [Node 023] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[1]: [object Map] 20:37:48.528 SERIAL » [ACK] (0x06) 20:37:48.529 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 1 commands: · Battery: 0x03 · Device Reset Locally: 0x01 · Thermostat Mode: 0x03 · Thermostat Setpoint: 0x03 · Notification: 0x05 · Protection: 0x03 · Multilevel Switch: 0x03 · Multilevel Sensor: 0x05 20:37:48.530 SERIAL » 0x010a001303038e0203255814 (12 bytes) 20:37:48.530 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 88 └─[MultiChannelAssociationCCGet] group id: 3 20:37:48.531 CNTRLR [Node 023] [+] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true 20:37:48.534 SERIAL « [ACK] (0x06) 20:37:48.535 CNTRLR [Node 023] NotificationCC: doing a complete interview... 20:37:48.535 CNTRLR » [Node 023] querying supported notification types... 20:37:48.536 SERIAL « 0x0104011301e8 (6 bytes) 20:37:48.536 SERIAL » [ACK] (0x06) 20:37:48.536 DRIVER « [RES] [SendData] was sent: true 20:37:48.618 SERIAL « 0x0107001358000008bb (9 bytes) 20:37:48.619 SERIAL » [ACK] (0x06) 20:37:48.619 DRIVER « [REQ] [SendData] callback id: 88 transmit status: OK 20:37:48.631 SERIAL « 0x010b00040003058e03030a0072 (13 bytes) 20:37:48.632 SERIAL » [ACK] (0x06) 20:37:48.633 CNTRLR [Node 003] [+] [Multi Channel Association] maxNodes[3]: 10 20:37:48.634 CNTRLR [Node 003] [+] [Multi Channel Association] nodeIds[3]: 20:37:48.635 CNTRLR [Node 003] [+] [Multi Channel Association] endpoints[3]: 20:37:48.636 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 3 maximum # of nodes: 10 node ids: endpoints: 20:37:48.641 SERIAL » 0x010b001318045905800125595a (13 bytes) 20:37:48.641 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 89 └─[AssociationGroupInfoCCCommandListGet] group id: 1 allow cache: true 20:37:48.642 CNTRLR « [Node 003] received information for multi channel association group #3: maximum # of nodes: 10 currently assigned nodes: currently assigned endpoints: 20:37:48.643 CNTRLR [Node 003] [+] [Association] hasLifeline: true [internal] 20:37:48.643 CNTRLR [Node 003] [+] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true 20:37:48.644 CNTRLR [Node 003] AssociationGroupInfoCC: doing a complete interview... 20:37:48.644 CNTRLR » [Node 003] Association group #1: Querying name... 20:37:48.648 SERIAL « [ACK] (0x06) 20:37:48.649 SERIAL « 0x0104011301e8 (6 bytes) 20:37:48.649 SERIAL » [ACK] (0x06) 20:37:48.650 DRIVER « [RES] [SendData] was sent: true 20:37:50.032 SERIAL « 0x010700135900008b39 (9 bytes) 20:37:50.033 SERIAL » [ACK] (0x06) 20:37:50.034 DRIVER « [REQ] [SendData] callback id: 89 transmit status: OK 20:37:50.117 SERIAL « 0x011a00040018145906011080035a014003430371057503260331056b (28 bytes) 20:37:50.118 CNTRLR [Node 024] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[1]: [object Map] 20:37:50.118 SERIAL » [ACK] (0x06) 20:37:50.118 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 1 commands: · Battery: 0x03 · Device Reset Locally: 0x01 · Thermostat Mode: 0x03 · Thermostat Setpoint: 0x03 · Notification: 0x05 · Protection: 0x03 · Multilevel Switch: 0x03 · Multilevel Sensor: 0x05 20:37:50.122 SERIAL » 0x010a00131a03310304255ab6 (12 bytes) 20:37:50.123 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 90 └─[MultilevelSensorCCGetSupportedScale] sensor type: Power 20:37:50.123 CNTRLR [Node 024] [+] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true 20:37:50.128 SERIAL « [ACK] (0x06) 20:37:50.132 SERIAL « 0x0104011301e8 (6 bytes) 20:37:50.132 SERIAL » [ACK] (0x06) 20:37:50.133 DRIVER « [RES] [SendData] was sent: true 20:37:50.135 CNTRLR [Node 024] NotificationCC: doing a complete interview... 20:37:50.135 CNTRLR » [Node 024] querying supported notification types... 20:37:50.204 SERIAL « 0x010700135a000008b9 (9 bytes) 20:37:50.204 SERIAL » [ACK] (0x06) 20:37:50.204 DRIVER « [REQ] [SendData] callback id: 90 transmit status: OK 20:37:50.214 SERIAL « 0x010a0004001a0431060401dd (12 bytes) 20:37:50.214 CNTRLR [Node 026] [+] [Multilevel Sensor] supportedScales[4]: [Endpoint 0] [internal] 0 20:37:50.214 SERIAL » [ACK] (0x06) 20:37:50.214 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedScaleReport] sensor type: Power supported scales: · Watt 20:37:50.216 SERIAL » 0x010a00131c03310304255bb1 (12 bytes) 20:37:50.216 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 91 └─[MultilevelSensorCCGetSupportedScale] sensor type: Power 20:37:50.216 CNTRLR « [Node 026] received supported scales: · Watt 20:37:50.216 CNTRLR » [Node 026] querying Power sensor reading... 20:37:50.217 SERIAL « [ACK] (0x06) 20:37:50.221 SERIAL « 0x0104011301e8 (6 bytes) 20:37:50.221 SERIAL » [ACK] (0x06) 20:37:50.221 DRIVER « [RES] [SendData] was sent: true 20:37:50.280 SERIAL « 0x010700135b000007b7 (9 bytes) 20:37:50.280 SERIAL » [ACK] (0x06) 20:37:50.281 DRIVER « [REQ] [SendData] callback id: 91 transmit status: OK 20:37:50.356 SERIAL « 0x010a0004001c0431060401db (12 bytes) 20:37:50.357 CNTRLR [Node 028] [+] [Multilevel Sensor] supportedScales[4]: [Endpoint 0] [internal] 0 20:37:50.357 SERIAL » [ACK] (0x06) 20:37:50.358 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedScaleReport] sensor type: Power supported scales: · Watt 20:37:50.362 SERIAL » 0x010b0013130431040400255cb8 (13 bytes) 20:37:50.362 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 92 └─[MultilevelSensorCCGet] sensor type: Power scale: Watt 20:37:50.362 CNTRLR « [Node 028] received supported scales: · Watt 20:37:50.363 CNTRLR » [Node 028] querying Power sensor reading... 20:37:50.366 SERIAL « [ACK] (0x06) 20:37:50.367 SERIAL « 0x0104011301e8 (6 bytes) 20:37:50.368 SERIAL » [ACK] (0x06) 20:37:50.371 DRIVER « [RES] [SendData] was sent: true 20:37:50.563 SERIAL « 0x010700135c000014a3 (9 bytes) 20:37:50.563 SERIAL » [ACK] (0x06) 20:37:50.564 DRIVER « [REQ] [SendData] callback id: 92 transmit status: OK 20:37:50.698 SERIAL « 0x010c0004001306310504220000f0 (14 bytes) 20:37:50.699 CNTRLR [Node 019] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:37:50.700 CNTRLR [Node 019] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 20:37:50.701 SERIAL » [ACK] (0x06) 20:37:50.702 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 20:37:50.705 SERIAL » 0x0109001315027107255dfc (11 bytes) 20:37:50.706 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 93 └─[NotificationCCSupportedGet] 20:37:50.706 CNTRLR « [Node 019] received current Power sensor reading: 0 W 20:37:50.706 CNTRLR [Node 019] [+] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true 20:37:50.716 SERIAL « [ACK] (0x06) 20:37:50.718 SERIAL « 0x0104011301e8 (6 bytes) 20:37:50.719 SERIAL » [ACK] (0x06) 20:37:50.719 DRIVER « [RES] [SendData] was sent: true 20:37:50.721 CNTRLR [Node 019] AssociationCC: doing a complete interview... 20:37:50.721 CNTRLR » [Node 019] querying number of association groups... 20:37:52.175 SERIAL « 0x010700135d00009325 (9 bytes) 20:37:52.175 SERIAL » [ACK] (0x06) 20:37:52.176 DRIVER « [REQ] [SendData] callback id: 93 transmit status: OK 20:37:52.260 SERIAL « 0x010b0004001505710802000398 (13 bytes) 20:37:52.261 CNTRLR [Node 021] [+] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" 20:37:52.262 CNTRLR [Node 021] [+] [Notification] supportedNotificationTyp [Endpoint 0] [internal] es: 8,9 20:37:52.262 CNTRLR [Node 021] [+] [Notification] supportsV1Alarm: false [Endpoint 0] [internal] 20:37:52.262 CNTRLR [Node 021] [~] [Notification] supportedNotificationTyp [Endpoint 0] [internal] es: 8,9 => 8,9 20:37:52.263 SERIAL » [ACK] (0x06) 20:37:52.264 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[NotificationCCSupportedReport] supports V1 alarm: false supported notification types: · Power Management · System 20:37:52.267 SERIAL » 0x0109001316027107255efc (11 bytes) 20:37:52.267 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 94 └─[NotificationCCSupportedGet] 20:37:52.268 CNTRLR « [Node 021] received supported notification types: · Power Management · System 20:37:52.268 CNTRLR » [Node 021] querying supported notification events for Power Management... 20:37:52.272 SERIAL « [ACK] (0x06) 20:37:52.273 SERIAL « 0x0104011301e8 (6 bytes) 20:37:52.273 SERIAL » [ACK] (0x06) 20:37:52.274 DRIVER « [RES] [SendData] was sent: true 20:37:53.930 SERIAL « 0x010700135e0000a712 (9 bytes) 20:37:53.930 SERIAL » [ACK] (0x06) 20:37:53.931 DRIVER « [REQ] [SendData] callback id: 94 transmit status: OK 20:37:54.008 SERIAL « 0x010b000400160571080200039b (13 bytes) 20:37:54.009 CNTRLR [Node 022] [+] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" 20:37:54.009 CNTRLR [Node 022] [+] [Notification] supportedNotificationTyp [Endpoint 0] [internal] es: 8,9 20:37:54.012 CNTRLR [Node 022] [+] [Notification] supportsV1Alarm: false [Endpoint 0] [internal] 20:37:54.012 CNTRLR [Node 022] [~] [Notification] supportedNotificationTyp [Endpoint 0] [internal] es: 8,9 => 8,9 20:37:54.012 SERIAL » [ACK] (0x06) 20:37:54.013 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[NotificationCCSupportedReport] supports V1 alarm: false supported notification types: · Power Management · System 20:37:54.014 SERIAL » 0x0109001317027107255ffc (11 bytes) 20:37:54.014 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 95 └─[NotificationCCSupportedGet] 20:37:54.014 CNTRLR « [Node 022] received supported notification types: · Power Management · System 20:37:54.014 CNTRLR » [Node 022] querying supported notification events for Power Management... 20:37:54.015 SERIAL « [ACK] (0x06) 20:37:54.019 SERIAL « 0x0104011301e8 (6 bytes) 20:37:54.019 SERIAL » [ACK] (0x06) 20:37:54.020 DRIVER « [RES] [SendData] was sent: true 20:37:55.442 SERIAL « 0x010c0004001a0631050422088e7f (14 bytes) 20:37:55.443 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:37:55.443 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 258.5 => 219 [Endpoint 0] 20:37:55.444 SERIAL » [ACK] (0x06) 20:37:55.446 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 219 20:37:55.466 SERIAL « 0x010700135f00009125 (9 bytes) 20:37:55.466 SERIAL » [ACK] (0x06) 20:37:55.466 DRIVER « [REQ] [SendData] callback id: 95 transmit status: OK 20:37:55.548 SERIAL « 0x010b000400170571080200039a (13 bytes) 20:37:55.549 CNTRLR [Node 023] [+] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" 20:37:55.549 CNTRLR [Node 023] [+] [Notification] supportedNotificationTyp [Endpoint 0] [internal] es: 8,9 20:37:55.550 CNTRLR [Node 023] [+] [Notification] supportsV1Alarm: false [Endpoint 0] [internal] 20:37:55.550 CNTRLR [Node 023] [~] [Notification] supportedNotificationTyp [Endpoint 0] [internal] es: 8,9 => 8,9 20:37:55.550 SERIAL » [ACK] (0x06) 20:37:55.551 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[NotificationCCSupportedReport] supports V1 alarm: false supported notification types: · Power Management · System 20:37:55.553 SERIAL » 0x010a001303035901012560fa (12 bytes) 20:37:55.553 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 96 └─[AssociationGroupInfoCCNameGet] group id: 1 20:37:55.553 CNTRLR « [Node 023] received supported notification types: · Power Management · System 20:37:55.553 CNTRLR » [Node 023] querying supported notification events for Power Management... 20:37:55.554 SERIAL « [ACK] (0x06) 20:37:55.559 SERIAL « 0x0104011301e8 (6 bytes) 20:37:55.559 SERIAL » [ACK] (0x06) 20:37:55.560 DRIVER « [RES] [SendData] was sent: true 20:37:55.639 SERIAL « 0x010700136000000883 (9 bytes) 20:37:55.639 SERIAL » [ACK] (0x06) 20:37:55.640 DRIVER « [REQ] [SendData] callback id: 96 transmit status: OK 20:37:55.653 SERIAL « 0x0112000400030c590201084c6966656c696e659c (20 bytes) 20:37:55.654 CNTRLR [Node 003] [+] [Association Group Information] name[1]: "Lifeline" [internal] 20:37:55.654 SERIAL » [ACK] (0x06) 20:37:55.655 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 1 name: Lifeline 20:37:55.658 SERIAL » 0x01090013180271072561cd (11 bytes) 20:37:55.658 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 97 └─[NotificationCCSupportedGet] 20:37:55.659 CNTRLR « [Node 003] Association group #1 has name "Lifeline" 20:37:55.659 CNTRLR » [Node 003] Association group #1: Querying info... 20:37:55.661 SERIAL « [ACK] (0x06) 20:37:55.663 SERIAL « 0x0104011301e8 (6 bytes) 20:37:55.664 SERIAL » [ACK] (0x06) 20:37:55.664 DRIVER « [RES] [SendData] was sent: true 20:37:57.065 SERIAL « 0x010700136100008c06 (9 bytes) 20:37:57.065 SERIAL » [ACK] (0x06) 20:37:57.066 DRIVER « [REQ] [SendData] callback id: 97 transmit status: OK 20:37:57.141 SERIAL « 0x010b0004001805710802000395 (13 bytes) 20:37:57.142 CNTRLR [Node 024] [+] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" 20:37:57.142 CNTRLR [Node 024] [+] [Notification] supportedNotificationTyp [Endpoint 0] [internal] es: 8,9 20:37:57.142 CNTRLR [Node 024] [+] [Notification] supportsV1Alarm: false [Endpoint 0] [internal] 20:37:57.142 CNTRLR [Node 024] [~] [Notification] supportedNotificationTyp [Endpoint 0] [internal] es: 8,9 => 8,9 20:37:57.142 SERIAL » [ACK] (0x06) 20:37:57.143 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[NotificationCCSupportedReport] supports V1 alarm: false supported notification types: · Power Management · System 20:37:57.146 SERIAL » 0x010b00131a043104040025628f (13 bytes) 20:37:57.146 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 98 └─[MultilevelSensorCCGet] sensor type: Power scale: Watt 20:37:57.146 CNTRLR « [Node 024] received supported notification types: · Power Management · System 20:37:57.146 CNTRLR » [Node 024] querying supported notification events for Power Management... 20:37:57.147 SERIAL « [ACK] (0x06) 20:37:57.152 SERIAL « 0x0104011301e8 (6 bytes) 20:37:57.152 SERIAL » [ACK] (0x06) 20:37:57.152 DRIVER « [RES] [SendData] was sent: true 20:37:57.224 SERIAL « 0x010700136200000881 (9 bytes) 20:37:57.224 SERIAL » [ACK] (0x06) 20:37:57.225 DRIVER « [REQ] [SendData] callback id: 98 transmit status: OK 20:37:57.234 SERIAL « 0x010c0004001a063105042208d726 (14 bytes) 20:37:57.235 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:37:57.236 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 219 => 226.3 [Endpoint 0] 20:37:57.236 SERIAL » [ACK] (0x06) 20:37:57.237 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 226.3 20:37:57.243 SERIAL » 0x010b00131c0431040400256388 (13 bytes) 20:37:57.243 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 99 └─[MultilevelSensorCCGet] sensor type: Power scale: Watt 20:37:57.244 CNTRLR « [Node 026] received current Power sensor reading: 226.3 W 20:37:57.244 CNTRLR [Node 026] [+] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true 20:37:57.249 SERIAL « [ACK] (0x06) 20:37:57.251 SERIAL « 0x0104011301e8 (6 bytes) 20:37:57.251 SERIAL » [ACK] (0x06) 20:37:57.252 DRIVER « [RES] [SendData] was sent: true 20:37:57.254 CNTRLR [Node 026] AssociationCC: doing a complete interview... 20:37:57.254 CNTRLR » [Node 026] querying number of association groups... 20:37:57.308 SERIAL « 0x01070013630000068e (9 bytes) 20:37:57.308 SERIAL » [ACK] (0x06) 20:37:57.309 DRIVER « [REQ] [SendData] callback id: 99 transmit status: OK 20:37:57.387 SERIAL « 0x010c0004001c063105042202926f (14 bytes) 20:37:57.388 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:37:57.388 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 67.7 => 65.8 [Endpoint 0] 20:37:57.389 SERIAL » [ACK] (0x06) 20:37:57.389 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 65.8 20:37:57.393 SERIAL » 0x0109001313028505256435 (11 bytes) 20:37:57.393 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 100 └─[AssociationCCSupportedGroupingsGet] 20:37:57.393 CNTRLR « [Node 028] received current Power sensor reading: 65.8 W 20:37:57.393 CNTRLR [Node 028] [+] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true 20:37:57.394 CNTRLR [Node 028] AssociationCC: doing a complete interview... 20:37:57.394 CNTRLR » [Node 028] querying number of association groups... 20:37:57.401 SERIAL « [ACK] (0x06) 20:37:57.403 SERIAL « 0x0104011301e8 (6 bytes) 20:37:57.403 SERIAL » [ACK] (0x06) 20:37:57.404 DRIVER « [RES] [SendData] was sent: true 20:37:57.549 SERIAL « 0x010700136400000f80 (9 bytes) 20:37:57.549 SERIAL » [ACK] (0x06) 20:37:57.549 DRIVER « [REQ] [SendData] callback id: 100 transmit status: OK 20:37:57.673 SERIAL « 0x0109000400130385060362 (11 bytes) 20:37:57.674 CNTRLR [Node 019] [+] [Association] groupCount: 3 [Endpoint 0] [internal] 20:37:57.674 SERIAL » [ACK] (0x06) 20:37:57.675 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[AssociationCCSupportedGroupingsReport] group count: 3 20:37:57.678 SERIAL » 0x010a001315037101082565c8 (12 bytes) 20:37:57.679 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 101 └─[NotificationCCEventSupportedGet] notification type: Power Management 20:37:57.679 CNTRLR « [Node 019] supports 3 association groups 20:37:57.679 CNTRLR [Node 019] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 20:37:57.679 CNTRLR [Node 019] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 20:37:57.680 CNTRLR [Node 019] MultiChannelAssociationCC: doing a complete interview... 20:37:57.680 CNTRLR » [Node 019] querying number of multi channel association groups... 20:37:57.682 SERIAL « [ACK] (0x06) 20:37:57.694 SERIAL « 0x0104011301e8 (6 bytes) 20:37:57.695 SERIAL » [ACK] (0x06) 20:37:57.695 DRIVER « [RES] [SendData] was sent: true 20:37:59.191 SERIAL « 0x010700136500009719 (9 bytes) 20:37:59.191 SERIAL » [ACK] (0x06) 20:37:59.192 DRIVER « [REQ] [SendData] callback id: 101 transmit status: OK 20:37:59.275 SERIAL « 0x010c000400150671020802000c91 (14 bytes) 20:37:59.276 CNTRLR [Node 021] [~] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" => "unknown" 20:37:59.277 CNTRLR [Node 021] [+] [Notification] supportedNotificationEvents[8]: 10,11 [internal] 20:37:59.278 CNTRLR [Node 021] [Notification] Power Management[Battery maintenance st [Endpoint 0] atus]: metadata updated 20:37:59.278 SERIAL » [ACK] (0x06) 20:37:59.280 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[NotificationCCEventSupportedReport] notification type: Power Management supported events: · Unknown (0x0a) · Unknown (0x0b) 20:37:59.282 SERIAL » 0x0109001313028e0525663c (11 bytes) 20:37:59.283 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 102 └─[MultiChannelAssociationCCSupportedGroupingsGet] 20:37:59.283 CNTRLR « [Node 021] received supported notification events for Power Management: 10, 11 20:37:59.283 CNTRLR » [Node 021] querying supported notification events for System... 20:37:59.286 SERIAL « [ACK] (0x06) 20:37:59.288 SERIAL « 0x0104011301e8 (6 bytes) 20:37:59.288 SERIAL » [ACK] (0x06) 20:37:59.289 DRIVER « [RES] [SendData] was sent: true 20:37:59.489 SERIAL « 0x010700136600001499 (9 bytes) 20:37:59.489 SERIAL » [ACK] (0x06) 20:37:59.490 DRIVER « [REQ] [SendData] callback id: 102 transmit status: OK 20:37:59.613 SERIAL « 0x010900040013038e060369 (11 bytes) 20:37:59.614 CNTRLR [Node 019] [+] [Multi Channel Association] groupCount: [Endpoint 0] [internal] 3 20:37:59.614 SERIAL » [ACK] (0x06) 20:37:59.615 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCSupportedGroupingsReport] group count: 3 20:37:59.617 SERIAL » 0x010a001316037101082567c9 (12 bytes) 20:37:59.618 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 103 └─[NotificationCCEventSupportedGet] notification type: Power Management 20:37:59.618 CNTRLR « [Node 019] supports 3 multi channel association groups 20:37:59.618 CNTRLR » [Node 019] querying multi channel association group #1... 20:37:59.621 SERIAL « [ACK] (0x06) 20:37:59.623 SERIAL « 0x0104011301e8 (6 bytes) 20:37:59.623 SERIAL » [ACK] (0x06) 20:37:59.624 DRIVER « [RES] [SendData] was sent: true 20:38:01.324 SERIAL « 0x01070013670000aa26 (9 bytes) 20:38:01.324 SERIAL » [ACK] (0x06) 20:38:01.325 DRIVER « [REQ] [SendData] callback id: 103 transmit status: OK 20:38:01.407 SERIAL « 0x010c000400160671020802000c92 (14 bytes) 20:38:01.407 CNTRLR [Node 022] [~] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" => "unknown" 20:38:01.408 CNTRLR [Node 022] [+] [Notification] supportedNotificationEvents[8]: 10,11 [internal] 20:38:01.408 CNTRLR [Node 022] [Notification] Power Management[Battery maintenance st [Endpoint 0] atus]: metadata updated 20:38:01.409 SERIAL » [ACK] (0x06) 20:38:01.410 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[NotificationCCEventSupportedReport] notification type: Power Management supported events: · Unknown (0x0a) · Unknown (0x0b) 20:38:01.412 SERIAL » 0x010a001313038e0201256836 (12 bytes) 20:38:01.412 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 104 └─[MultiChannelAssociationCCGet] group id: 1 20:38:01.412 CNTRLR « [Node 022] received supported notification events for Power Management: 10, 11 20:38:01.412 CNTRLR » [Node 022] querying supported notification events for System... 20:38:01.414 SERIAL « [ACK] (0x06) 20:38:01.418 SERIAL « 0x0104011301e8 (6 bytes) 20:38:01.418 SERIAL » [ACK] (0x06) 20:38:01.418 DRIVER « [RES] [SendData] was sent: true 20:38:01.621 SERIAL « 0x010700136800001596 (9 bytes) 20:38:01.622 SERIAL » [ACK] (0x06) 20:38:01.622 DRIVER « [REQ] [SendData] callback id: 104 transmit status: OK 20:38:01.751 SERIAL « 0x010e00040013088e0301010000010062 (16 bytes) 20:38:01.752 SERIAL » [ACK] (0x06) 20:38:01.752 CNTRLR [Node 019] [+] [Multi Channel Association] maxNodes[1]: 1 20:38:01.753 CNTRLR [Node 019] [+] [Multi Channel Association] nodeIds[1]: 20:38:01.753 CNTRLR [Node 019] [+] [Multi Channel Association] endpoints[1]: [object Object] 20:38:01.753 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 1 node ids: endpoints: 1:0 20:38:01.756 SERIAL » 0x010a001317037101082569c6 (12 bytes) 20:38:01.756 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 105 └─[NotificationCCEventSupportedGet] notification type: Power Management 20:38:01.756 CNTRLR « [Node 019] received information for multi channel association group #1: maximum # of nodes: 1 currently assigned nodes: currently assigned endpoints: 1:0 20:38:01.756 CNTRLR » [Node 019] querying multi channel association group #2... 20:38:01.758 SERIAL « [ACK] (0x06) 20:38:01.762 SERIAL « 0x0104011301e8 (6 bytes) 20:38:01.762 SERIAL » [ACK] (0x06) 20:38:01.762 DRIVER « [RES] [SendData] was sent: true 20:38:01.901 SERIAL « 0x010c0004001a063105042210b950 (14 bytes) 20:38:01.902 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:38:01.903 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 226.3 => 428.1 [Endpoint 0] 20:38:01.903 SERIAL » [ACK] (0x06) 20:38:01.904 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 428.1 20:38:03.373 SERIAL « 0x010c0004001a0631050422086c9d (14 bytes) 20:38:03.374 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:38:03.375 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 428.1 => 215.6 [Endpoint 0] 20:38:03.375 SERIAL » [ACK] (0x06) 20:38:03.376 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 215.6 20:38:03.397 SERIAL « 0x01070013690000a426 (9 bytes) 20:38:03.397 SERIAL » [ACK] (0x06) 20:38:03.398 DRIVER « [REQ] [SendData] callback id: 105 transmit status: OK 20:38:03.509 SERIAL « 0x010c000400170671020802000c93 (14 bytes) 20:38:03.510 CNTRLR [Node 023] [~] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" => "unknown" 20:38:03.510 CNTRLR [Node 023] [+] [Notification] supportedNotificationEvents[8]: 10,11 [internal] 20:38:03.511 CNTRLR [Node 023] [Notification] Power Management[Battery maintenance st [Endpoint 0] atus]: metadata updated 20:38:03.511 SERIAL » [ACK] (0x06) 20:38:03.512 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[NotificationCCEventSupportedReport] notification type: Power Management supported events: · Unknown (0x0a) · Unknown (0x0b) 20:38:03.515 SERIAL » 0x010a001313038e0202256a37 (12 bytes) 20:38:03.515 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 106 └─[MultiChannelAssociationCCGet] group id: 2 20:38:03.516 CNTRLR « [Node 023] received supported notification events for Power Management: 10, 11 20:38:03.516 CNTRLR » [Node 023] querying supported notification events for System... 20:38:03.518 SERIAL « [ACK] (0x06) 20:38:03.521 SERIAL « 0x0104011301e8 (6 bytes) 20:38:03.521 SERIAL » [ACK] (0x06) 20:38:03.521 DRIVER « [RES] [SendData] was sent: true 20:38:03.721 SERIAL « 0x010700136a00001594 (9 bytes) 20:38:03.722 SERIAL » [ACK] (0x06) 20:38:03.722 DRIVER « [REQ] [SendData] callback id: 106 transmit status: OK 20:38:03.826 SERIAL « 0x010b00040013058e03020a0063 (13 bytes) 20:38:03.827 SERIAL » [ACK] (0x06) 20:38:03.827 CNTRLR [Node 019] [+] [Multi Channel Association] maxNodes[2]: 10 20:38:03.828 CNTRLR [Node 019] [+] [Multi Channel Association] nodeIds[2]: 20:38:03.829 CNTRLR [Node 019] [+] [Multi Channel Association] endpoints[2]: 20:38:03.830 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 10 node ids: endpoints: 20:38:03.836 SERIAL » 0x010b0013030459030001256bf5 (13 bytes) 20:38:03.837 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 107 └─[AssociationGroupInfoCCInfoGet] group id: 1 refresh cache: false 20:38:03.837 CNTRLR « [Node 019] received information for multi channel association group #2: maximum # of nodes: 10 currently assigned nodes: currently assigned endpoints: 20:38:03.837 CNTRLR » [Node 019] querying multi channel association group #3... 20:38:03.842 SERIAL « [ACK] (0x06) 20:38:03.847 SERIAL « 0x0104011301e8 (6 bytes) 20:38:03.848 SERIAL » [ACK] (0x06) 20:38:03.848 DRIVER « [RES] [SendData] was sent: true 20:38:03.959 SERIAL « 0x010700136b00000c8c (9 bytes) 20:38:03.960 SERIAL » [ACK] (0x06) 20:38:03.960 DRIVER « [REQ] [SendData] callback id: 107 transmit status: OK 20:38:03.973 SERIAL « 0x0110000400030a59040101000001000000be (18 bytes) 20:38:03.974 CNTRLR [Node 003] [+] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false 20:38:03.974 CNTRLR [Node 003] [+] [Association Group Information] info[1]: [object Obj [internal] ect] 20:38:03.975 SERIAL » [ACK] (0x06) 20:38:03.975 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #1 mode: 0 profile: 1 event code: 0 20:38:03.982 SERIAL » 0x010a001313038e0203256c30 (12 bytes) 20:38:03.982 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 108 └─[MultiChannelAssociationCCGet] group id: 3 20:38:03.983 CNTRLR « [Node 003] Received info for association group #1: info is dynamic: false profile: General: Lifeline 20:38:03.983 CNTRLR » [Node 003] Association group #1: Querying command list... 20:38:03.987 SERIAL « [ACK] (0x06) 20:38:03.988 SERIAL « 0x0104011301e8 (6 bytes) 20:38:03.988 SERIAL » [ACK] (0x06) 20:38:03.989 DRIVER « [RES] [SendData] was sent: true 20:38:04.130 SERIAL « 0x010700136c00000f88 (9 bytes) 20:38:04.130 SERIAL » [ACK] (0x06) 20:38:04.131 DRIVER « [REQ] [SendData] callback id: 108 transmit status: OK 20:38:04.256 SERIAL « 0x010b00040013058e03030a0062 (13 bytes) 20:38:04.257 SERIAL » [ACK] (0x06) 20:38:04.258 CNTRLR [Node 019] [+] [Multi Channel Association] maxNodes[3]: 10 20:38:04.259 CNTRLR [Node 019] [+] [Multi Channel Association] nodeIds[3]: 20:38:04.260 CNTRLR [Node 019] [+] [Multi Channel Association] endpoints[3]: 20:38:04.261 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 3 maximum # of nodes: 10 node ids: endpoints: 20:38:04.263 SERIAL » 0x010a00131803710108256dcd (12 bytes) 20:38:04.264 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 109 └─[NotificationCCEventSupportedGet] notification type: Power Management 20:38:04.264 CNTRLR « [Node 019] received information for multi channel association group #3: maximum # of nodes: 10 currently assigned nodes: currently assigned endpoints: 20:38:04.265 CNTRLR [Node 019] [+] [Association] hasLifeline: true [internal] 20:38:04.265 CNTRLR [Node 019] [+] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true 20:38:04.271 SERIAL « [ACK] (0x06) 20:38:04.273 SERIAL « 0x0104011301e8 (6 bytes) 20:38:04.273 SERIAL » [ACK] (0x06) 20:38:04.274 DRIVER « [RES] [SendData] was sent: true 20:38:04.276 CNTRLR [Node 019] AssociationGroupInfoCC: doing a complete interview... 20:38:04.276 CNTRLR » [Node 019] Association group #1: Querying name... 20:38:05.833 SERIAL « 0x010700136d00009d1b (9 bytes) 20:38:05.833 SERIAL » [ACK] (0x06) 20:38:05.834 DRIVER « [REQ] [SendData] callback id: 109 transmit status: OK 20:38:05.909 SERIAL « 0x010c000400180671020802000c9c (14 bytes) 20:38:05.910 CNTRLR [Node 024] [~] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" => "unknown" 20:38:05.911 CNTRLR [Node 024] [+] [Notification] supportedNotificationEvents[8]: 10,11 [internal] 20:38:05.912 CNTRLR [Node 024] [Notification] Power Management[Battery maintenance st [Endpoint 0] atus]: metadata updated 20:38:05.912 SERIAL » [ACK] (0x06) 20:38:05.913 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[NotificationCCEventSupportedReport] notification type: Power Management supported events: · Unknown (0x0a) · Unknown (0x0b) 20:38:05.915 SERIAL » 0x010900131a028505256e36 (11 bytes) 20:38:05.915 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 110 └─[AssociationCCSupportedGroupingsGet] 20:38:05.915 CNTRLR « [Node 024] received supported notification events for Power Management: 10, 11 20:38:05.915 CNTRLR » [Node 024] querying supported notification events for System... 20:38:05.916 SERIAL « [ACK] (0x06) 20:38:05.920 SERIAL « 0x0104011301e8 (6 bytes) 20:38:05.920 SERIAL » [ACK] (0x06) 20:38:05.921 DRIVER « [RES] [SendData] was sent: true 20:38:05.994 SERIAL « 0x010700136e0000088d (9 bytes) 20:38:05.994 SERIAL » [ACK] (0x06) 20:38:05.995 DRIVER « [REQ] [SendData] callback id: 110 transmit status: OK 20:38:06.004 SERIAL « 0x01090004001a038506036b (11 bytes) 20:38:06.005 CNTRLR [Node 026] [+] [Association] groupCount: 3 [Endpoint 0] [internal] 20:38:06.005 SERIAL » [ACK] (0x06) 20:38:06.006 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[AssociationCCSupportedGroupingsReport] group count: 3 20:38:06.009 SERIAL » 0x010900131c028505256f31 (11 bytes) 20:38:06.009 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 111 └─[AssociationCCSupportedGroupingsGet] 20:38:06.009 CNTRLR « [Node 026] supports 3 association groups 20:38:06.010 CNTRLR [Node 026] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 20:38:06.010 CNTRLR [Node 026] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 20:38:06.015 SERIAL « [ACK] (0x06) 20:38:06.016 SERIAL « 0x0104011301e8 (6 bytes) 20:38:06.017 SERIAL » [ACK] (0x06) 20:38:06.017 DRIVER « [RES] [SendData] was sent: true 20:38:06.019 CNTRLR [Node 026] MultiChannelAssociationCC: doing a complete interview... 20:38:06.019 CNTRLR » [Node 026] querying number of multi channel association groups... 20:38:06.073 SERIAL « 0x010700136f00000682 (9 bytes) 20:38:06.073 SERIAL » [ACK] (0x06) 20:38:06.074 DRIVER « [REQ] [SendData] callback id: 111 transmit status: OK 20:38:06.146 SERIAL « 0x01090004001c038506036d (11 bytes) 20:38:06.146 CNTRLR [Node 028] [+] [Association] groupCount: 3 [Endpoint 0] [internal] 20:38:06.147 SERIAL » [ACK] (0x06) 20:38:06.147 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[AssociationCCSupportedGroupingsReport] group count: 3 20:38:06.152 SERIAL » 0x010900131a028e05257023 (11 bytes) 20:38:06.152 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 112 └─[MultiChannelAssociationCCSupportedGroupingsGet] 20:38:06.153 CNTRLR « [Node 028] supports 3 association groups 20:38:06.153 CNTRLR [Node 028] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 20:38:06.153 CNTRLR [Node 028] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 20:38:06.153 CNTRLR [Node 028] MultiChannelAssociationCC: doing a complete interview... 20:38:06.154 CNTRLR » [Node 028] querying number of multi channel association groups... 20:38:06.156 SERIAL « [ACK] (0x06) 20:38:06.158 SERIAL « 0x0104011301e8 (6 bytes) 20:38:06.158 SERIAL » [ACK] (0x06) 20:38:06.158 DRIVER « [RES] [SendData] was sent: true 20:38:06.224 SERIAL « 0x01070013700000079c (9 bytes) 20:38:06.224 SERIAL » [ACK] (0x06) 20:38:06.225 DRIVER « [REQ] [SendData] callback id: 112 transmit status: OK 20:38:06.234 SERIAL « 0x01090004001a038e060360 (11 bytes) 20:38:06.234 CNTRLR [Node 026] [+] [Multi Channel Association] groupCount: [Endpoint 0] [internal] 3 20:38:06.235 SERIAL » [ACK] (0x06) 20:38:06.235 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCSupportedGroupingsReport] group count: 3 20:38:06.238 SERIAL » 0x010900131c028e05257124 (11 bytes) 20:38:06.239 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 113 └─[MultiChannelAssociationCCSupportedGroupingsGet] 20:38:06.239 CNTRLR « [Node 026] supports 3 multi channel association groups 20:38:06.239 CNTRLR » [Node 026] querying multi channel association group #1... 20:38:06.242 SERIAL « [ACK] (0x06) 20:38:06.244 SERIAL « 0x0104011301e8 (6 bytes) 20:38:06.244 SERIAL » [ACK] (0x06) 20:38:06.245 DRIVER « [RES] [SendData] was sent: true 20:38:06.303 SERIAL « 0x01070013710000069c (9 bytes) 20:38:06.304 SERIAL » [ACK] (0x06) 20:38:06.307 DRIVER « [REQ] [SendData] callback id: 113 transmit status: OK 20:38:06.376 SERIAL « 0x01090004001c038e060366 (11 bytes) 20:38:06.376 CNTRLR [Node 028] [+] [Multi Channel Association] groupCount: [Endpoint 0] [internal] 3 20:38:06.377 SERIAL » [ACK] (0x06) 20:38:06.377 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCSupportedGroupingsReport] group count: 3 20:38:06.380 SERIAL » 0x010a00131a038e0201257225 (12 bytes) 20:38:06.380 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 114 └─[MultiChannelAssociationCCGet] group id: 1 20:38:06.380 CNTRLR « [Node 028] supports 3 multi channel association groups 20:38:06.381 CNTRLR » [Node 028] querying multi channel association group #1... 20:38:06.383 SERIAL « [ACK] (0x06) 20:38:06.385 SERIAL « 0x0104011301e8 (6 bytes) 20:38:06.386 SERIAL » [ACK] (0x06) 20:38:06.386 DRIVER « [RES] [SendData] was sent: true 20:38:06.464 SERIAL « 0x010700137200000891 (9 bytes) 20:38:06.464 SERIAL » [ACK] (0x06) 20:38:06.465 DRIVER « [REQ] [SendData] callback id: 114 transmit status: OK 20:38:06.475 SERIAL « 0x010e0004001a088e030101000001006b (16 bytes) 20:38:06.475 SERIAL » [ACK] (0x06) 20:38:06.476 CNTRLR [Node 026] [+] [Multi Channel Association] maxNodes[1]: 1 20:38:06.477 CNTRLR [Node 026] [+] [Multi Channel Association] nodeIds[1]: 20:38:06.478 CNTRLR [Node 026] [+] [Multi Channel Association] endpoints[1]: [object Object] 20:38:06.479 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 1 node ids: endpoints: 1:0 20:38:06.481 SERIAL » 0x010a00131c038e0201257322 (12 bytes) 20:38:06.482 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 115 └─[MultiChannelAssociationCCGet] group id: 1 20:38:06.482 CNTRLR « [Node 026] received information for multi channel association group #1: maximum # of nodes: 1 currently assigned nodes: currently assigned endpoints: 1:0 20:38:06.482 CNTRLR » [Node 026] querying multi channel association group #2... 20:38:06.485 SERIAL « [ACK] (0x06) 20:38:06.487 SERIAL « 0x0104011301e8 (6 bytes) 20:38:06.488 SERIAL » [ACK] (0x06) 20:38:06.488 DRIVER « [RES] [SendData] was sent: true 20:38:06.546 SERIAL « 0x01070013730000069e (9 bytes) 20:38:06.547 SERIAL » [ACK] (0x06) 20:38:06.547 DRIVER « [REQ] [SendData] callback id: 115 transmit status: OK 20:38:06.617 SERIAL « 0x010e0004001c088e030101000001006d (16 bytes) 20:38:06.618 SERIAL » [ACK] (0x06) 20:38:06.619 CNTRLR [Node 028] [+] [Multi Channel Association] maxNodes[1]: 1 20:38:06.620 CNTRLR [Node 028] [+] [Multi Channel Association] nodeIds[1]: 20:38:06.621 CNTRLR [Node 028] [+] [Multi Channel Association] endpoints[1]: [object Object] 20:38:06.621 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 1 node ids: endpoints: 1:0 20:38:06.625 SERIAL » 0x010a00131a038e0202257420 (12 bytes) 20:38:06.625 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 116 └─[MultiChannelAssociationCCGet] group id: 2 20:38:06.625 CNTRLR « [Node 028] received information for multi channel association group #1: maximum # of nodes: 1 currently assigned nodes: currently assigned endpoints: 1:0 20:38:06.625 CNTRLR » [Node 028] querying multi channel association group #2... 20:38:06.632 SERIAL « [ACK] (0x06) 20:38:06.634 SERIAL « 0x0104011301e8 (6 bytes) 20:38:06.634 SERIAL » [ACK] (0x06) 20:38:06.636 DRIVER « [RES] [SendData] was sent: true 20:38:06.704 SERIAL « 0x010700137400000897 (9 bytes) 20:38:06.704 SERIAL » [ACK] (0x06) 20:38:06.705 DRIVER « [REQ] [SendData] callback id: 116 transmit status: OK 20:38:06.714 SERIAL « 0x010b0004001a058e03020a006a (13 bytes) 20:38:06.714 SERIAL » [ACK] (0x06) 20:38:06.715 CNTRLR [Node 026] [+] [Multi Channel Association] maxNodes[2]: 10 20:38:06.716 CNTRLR [Node 026] [+] [Multi Channel Association] nodeIds[2]: 20:38:06.717 CNTRLR [Node 026] [+] [Multi Channel Association] endpoints[2]: 20:38:06.718 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 10 node ids: endpoints: 20:38:06.721 SERIAL » 0x010a00131c038e0202257527 (12 bytes) 20:38:06.722 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 117 └─[MultiChannelAssociationCCGet] group id: 2 20:38:06.722 CNTRLR « [Node 026] received information for multi channel association group #2: maximum # of nodes: 10 currently assigned nodes: currently assigned endpoints: 20:38:06.722 CNTRLR » [Node 026] querying multi channel association group #3... 20:38:06.725 SERIAL « [ACK] (0x06) 20:38:06.727 SERIAL « 0x0104011301e8 (6 bytes) 20:38:06.727 SERIAL » [ACK] (0x06) 20:38:06.728 DRIVER « [RES] [SendData] was sent: true 20:38:06.786 SERIAL « 0x010700137500000698 (9 bytes) 20:38:06.786 SERIAL » [ACK] (0x06) 20:38:06.786 DRIVER « [REQ] [SendData] callback id: 117 transmit status: OK 20:38:06.856 SERIAL « 0x010b0004001c058e03020a006c (13 bytes) 20:38:06.856 SERIAL » [ACK] (0x06) 20:38:06.857 CNTRLR [Node 028] [+] [Multi Channel Association] maxNodes[2]: 10 20:38:06.857 CNTRLR [Node 028] [+] [Multi Channel Association] nodeIds[2]: 20:38:06.857 CNTRLR [Node 028] [+] [Multi Channel Association] endpoints[2]: 20:38:06.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 10 node ids: endpoints: 20:38:06.859 SERIAL » 0x010a00131a038e0203257623 (12 bytes) 20:38:06.859 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 118 └─[MultiChannelAssociationCCGet] group id: 3 20:38:06.859 CNTRLR « [Node 028] received information for multi channel association group #2: maximum # of nodes: 10 currently assigned nodes: currently assigned endpoints: 20:38:06.859 CNTRLR » [Node 028] querying multi channel association group #3... 20:38:06.861 SERIAL « [ACK] (0x06) 20:38:06.865 SERIAL « 0x0104011301e8 (6 bytes) 20:38:06.865 SERIAL » [ACK] (0x06) 20:38:06.865 DRIVER « [RES] [SendData] was sent: true 20:38:06.944 SERIAL « 0x010700137600000895 (9 bytes) 20:38:06.944 SERIAL » [ACK] (0x06) 20:38:06.945 DRIVER « [REQ] [SendData] callback id: 118 transmit status: OK 20:38:06.954 SERIAL « 0x010b0004001a058e03030a006b (13 bytes) 20:38:06.954 SERIAL » [ACK] (0x06) 20:38:06.955 CNTRLR [Node 026] [+] [Multi Channel Association] maxNodes[3]: 10 20:38:06.956 CNTRLR [Node 026] [+] [Multi Channel Association] nodeIds[3]: 20:38:06.957 CNTRLR [Node 026] [+] [Multi Channel Association] endpoints[3]: 20:38:06.958 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 3 maximum # of nodes: 10 node ids: endpoints: 20:38:06.965 SERIAL » 0x010a00131c038e0203257724 (12 bytes) 20:38:06.965 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 119 └─[MultiChannelAssociationCCGet] group id: 3 20:38:06.965 CNTRLR « [Node 026] received information for multi channel association group #3: maximum # of nodes: 10 currently assigned nodes: currently assigned endpoints: 20:38:06.966 CNTRLR [Node 026] [+] [Association] hasLifeline: true [internal] 20:38:06.968 CNTRLR [Node 026] [+] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true 20:38:06.974 SERIAL « [ACK] (0x06) 20:38:06.975 SERIAL « 0x0104011301e8 (6 bytes) 20:38:06.975 SERIAL » [ACK] (0x06) 20:38:06.977 DRIVER « [RES] [SendData] was sent: true 20:38:06.980 CNTRLR [Node 026] AssociationGroupInfoCC: doing a complete interview... 20:38:06.981 CNTRLR » [Node 026] Association group #1: Querying name... 20:38:07.030 SERIAL « 0x01070013770000079b (9 bytes) 20:38:07.030 SERIAL » [ACK] (0x06) 20:38:07.031 DRIVER « [REQ] [SendData] callback id: 119 transmit status: OK 20:38:07.107 SERIAL « 0x010b0004001c058e03030a006d (13 bytes) 20:38:07.107 SERIAL » [ACK] (0x06) 20:38:07.108 CNTRLR [Node 028] [+] [Multi Channel Association] maxNodes[3]: 10 20:38:07.109 CNTRLR [Node 028] [+] [Multi Channel Association] nodeIds[3]: 20:38:07.110 CNTRLR [Node 028] [+] [Multi Channel Association] endpoints[3]: 20:38:07.111 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 3 maximum # of nodes: 10 node ids: endpoints: 20:38:07.115 SERIAL » 0x010a001315037101092578d4 (12 bytes) 20:38:07.116 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 120 └─[NotificationCCEventSupportedGet] notification type: System 20:38:07.116 CNTRLR « [Node 028] received information for multi channel association group #3: maximum # of nodes: 10 currently assigned nodes: currently assigned endpoints: 20:38:07.117 CNTRLR [Node 028] [+] [Association] hasLifeline: true [internal] 20:38:07.117 CNTRLR [Node 028] [+] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true 20:38:07.117 CNTRLR [Node 028] AssociationGroupInfoCC: doing a complete interview... 20:38:07.118 CNTRLR » [Node 028] Association group #1: Querying name... 20:38:07.122 SERIAL « [ACK] (0x06) 20:38:07.123 SERIAL « 0x0104011301e8 (6 bytes) 20:38:07.123 SERIAL » [ACK] (0x06) 20:38:07.124 DRIVER « [RES] [SendData] was sent: true 20:38:08.565 SERIAL « 0x010c0004000306310504220000e0 (14 bytes) 20:38:08.566 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:38:08.567 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 20:38:08.567 SERIAL » [ACK] (0x06) 20:38:08.568 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 20:38:09.760 SERIAL « 0x01070013780001099b (9 bytes) 20:38:09.760 SERIAL » [ACK] (0x06) 20:38:09.761 DRIVER « [REQ] [SendData] callback id: 120 transmit status: OK 20:38:09.839 SERIAL « 0x010b0004001505710209010893 (13 bytes) 20:38:09.840 CNTRLR [Node 021] [~] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" => "unknown" 20:38:09.840 CNTRLR [Node 021] [+] [Notification] supportedNotificationEvents[9]: 3 [internal] 20:38:09.840 CNTRLR [Node 021] [Notification] System[Hardware status]: metadata updat [Endpoint 0] ed 20:38:09.841 SERIAL » [ACK] (0x06) 20:38:09.842 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[NotificationCCEventSupportedReport] notification type: System supported events: · Unknown (0x03) 20:38:09.844 SERIAL » 0x010a001316037101092579d6 (12 bytes) 20:38:09.845 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 121 └─[NotificationCCEventSupportedGet] notification type: System 20:38:09.845 CNTRLR « [Node 021] received supported notification events for System: 3 20:38:09.845 CNTRLR [Node 021] [+] [Notification] interviewComplete: true [Endpoint 0] [internal] 20:38:09.850 SERIAL « [ACK] (0x06) 20:38:09.851 SERIAL « 0x0104011301e8 (6 bytes) 20:38:09.851 SERIAL » [ACK] (0x06) 20:38:09.852 DRIVER « [RES] [SendData] was sent: true 20:38:09.853 CNTRLR [Node 021] Interview stage completed: CommandClasses 20:38:09.853 CNTRLR [Node 021] Interview stage completed: OverwriteConfig 20:38:09.853 CNTRLR » [Node 021] requesting node neighbors... 20:38:11.459 SERIAL « 0x0110000400060a32022134000000000000c2 (18 bytes) 20:38:11.461 CNTRLR [Node 006] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:38:11.461 CNTRLR [Node 006] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:38:11.462 SERIAL » [ACK] (0x06) 20:38:11.463 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:38:11.495 SERIAL « 0x01070013790000a537 (9 bytes) 20:38:11.495 SERIAL » [ACK] (0x06) 20:38:11.496 DRIVER « [REQ] [SendData] callback id: 121 transmit status: OK 20:38:11.513 SERIAL « 0x0110000400060a32022134000000000000c2 (18 bytes) 20:38:11.514 CNTRLR [Node 006] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:38:11.514 CNTRLR [Node 006] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:38:11.515 SERIAL » [ACK] (0x06) 20:38:11.516 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:38:11.577 SERIAL « 0x010b0004001605710209010890 (13 bytes) 20:38:11.577 CNTRLR [Node 022] [~] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" => "unknown" 20:38:11.578 CNTRLR [Node 022] [+] [Notification] supportedNotificationEvents[9]: 3 [internal] 20:38:11.578 CNTRLR [Node 022] [Notification] System[Hardware status]: metadata updat [Endpoint 0] ed 20:38:11.579 SERIAL » [ACK] (0x06) 20:38:11.579 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[NotificationCCEventSupportedReport] notification type: System supported events: · Unknown (0x03) 20:38:11.582 SERIAL » 0x01070080150000006d (9 bytes) 20:38:11.582 DRIVER » [Node 021] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 20:38:11.583 CNTRLR « [Node 022] received supported notification events for System: 3 20:38:11.583 CNTRLR [Node 022] [+] [Notification] interviewComplete: true [Endpoint 0] [internal] 20:38:11.587 SERIAL « [ACK] (0x06) 20:38:11.589 SERIAL « 0x0120018037000a0a0000000000000000000000000000000000000000000000000 (34 bytes) 069 20:38:11.589 SERIAL » [ACK] (0x06) 20:38:11.590 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 2, 3, 5, 6, 18, 20, 26, 28 20:38:11.596 SERIAL » 0x010a00131703710109257ad4 (12 bytes) 20:38:11.597 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 122 └─[NotificationCCEventSupportedGet] notification type: System 20:38:11.597 CNTRLR « [Node 021] node neighbors received: 1, 2, 3, 5, 6, 18, 20, 26, 28 20:38:11.597 CNTRLR [Node 021] Interview stage completed: Neighbors 20:38:11.597 CNTRLR [Node 021] Interview completed 20:38:11.598 CNTRLR [Node 021] The node is ready to be used 20:38:11.600 CNTRLR [Node 022] Interview stage completed: CommandClasses 20:38:11.600 CNTRLR [Node 022] Interview stage completed: OverwriteConfig 20:38:11.601 CNTRLR » [Node 022] requesting node neighbors... 20:38:11.604 SERIAL « [ACK] (0x06) 20:38:11.604 SERIAL « 0x0104011301e8 (6 bytes) 20:38:11.605 SERIAL » [ACK] (0x06) 20:38:11.605 DRIVER « [RES] [SendData] was sent: true 20:38:13.033 SERIAL « 0x010700137a00009001 (9 bytes) 20:38:13.033 SERIAL » [ACK] (0x06) 20:38:13.034 DRIVER « [REQ] [SendData] callback id: 122 transmit status: OK 20:38:13.114 SERIAL « 0x010b0004001705710209010891 (13 bytes) 20:38:13.115 CNTRLR [Node 023] [~] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" => "unknown" 20:38:13.115 CNTRLR [Node 023] [+] [Notification] supportedNotificationEvents[9]: 3 [internal] 20:38:13.116 CNTRLR [Node 023] [Notification] System[Hardware status]: metadata updat [Endpoint 0] ed 20:38:13.116 SERIAL » [ACK] (0x06) 20:38:13.117 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[NotificationCCEventSupportedReport] notification type: System supported events: · Unknown (0x03) 20:38:13.119 SERIAL » 0x01070080160000006e (9 bytes) 20:38:13.119 DRIVER » [Node 022] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 20:38:13.119 CNTRLR « [Node 023] received supported notification events for System: 3 20:38:13.119 CNTRLR [Node 023] [+] [Notification] interviewComplete: true [Endpoint 0] [internal] 20:38:13.123 SERIAL « [ACK] (0x06) 20:38:13.124 SERIAL « 0x012001802100ce0b0000000000000000000000000000000000000000000000000 (34 bytes) 0ba 20:38:13.124 SERIAL » [ACK] (0x06) 20:38:13.124 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 6, 18, 19, 20, 23, 24, 25, 26, 28 20:38:13.126 SERIAL » 0x010b0013030459058001257b63 (13 bytes) 20:38:13.126 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 123 └─[AssociationGroupInfoCCCommandListGet] group id: 1 allow cache: true 20:38:13.127 CNTRLR « [Node 022] node neighbors received: 1, 6, 18, 19, 20, 23, 24, 25, 26, 28 20:38:13.127 CNTRLR [Node 022] Interview stage completed: Neighbors 20:38:13.127 CNTRLR [Node 022] Interview completed 20:38:13.127 CNTRLR [Node 022] The node is ready to be used 20:38:13.128 CNTRLR [Node 023] Interview stage completed: CommandClasses 20:38:13.128 CNTRLR [Node 023] Interview stage completed: OverwriteConfig 20:38:13.128 CNTRLR » [Node 023] requesting node neighbors... 20:38:13.129 SERIAL « [ACK] (0x06) 20:38:13.160 SERIAL « 0x0104011301e8 (6 bytes) 20:38:13.160 SERIAL » [ACK] (0x06) 20:38:13.160 DRIVER « [RES] [SendData] was sent: true 20:38:13.208 SERIAL « 0x010700137b00000898 (9 bytes) 20:38:13.209 SERIAL » [ACK] (0x06) 20:38:13.209 DRIVER « [REQ] [SendData] callback id: 123 transmit status: OK 20:38:13.223 SERIAL « 0x0114000400030e5906010a5a012503320231057105bb (22 bytes) 20:38:13.224 CNTRLR [Node 003] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[1]: [object Map] 20:38:13.224 SERIAL » [ACK] (0x06) 20:38:13.225 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 1 commands: · Device Reset Locally: 0x01 · Binary Switch: 0x03 · Meter: 0x02 · Multilevel Sensor: 0x05 · Notification: 0x05 20:38:13.227 SERIAL » 0x01070080170000006f (9 bytes) 20:38:13.227 DRIVER » [Node 023] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 20:38:13.227 CNTRLR » [Node 003] Association group #2: Querying name... 20:38:13.230 SERIAL « [ACK] (0x06) 20:38:13.231 SERIAL « 0x012001802500ae030000000000000000000000000000000000000000000000000 (34 bytes) 0d6 20:38:13.231 SERIAL » [ACK] (0x06) 20:38:13.232 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 18, 19, 20, 22, 24, 25, 26 20:38:13.235 SERIAL » 0x010a00131303590101257cf6 (12 bytes) 20:38:13.235 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 124 └─[AssociationGroupInfoCCNameGet] group id: 1 20:38:13.235 CNTRLR « [Node 023] node neighbors received: 1, 3, 6, 18, 19, 20, 22, 24, 25, 26 20:38:13.235 CNTRLR [Node 023] Interview stage completed: Neighbors 20:38:13.235 CNTRLR [Node 023] Interview completed 20:38:13.235 CNTRLR [Node 023] The node is ready to be used 20:38:13.238 SERIAL « [ACK] (0x06) 20:38:13.240 SERIAL « 0x0104011301e8 (6 bytes) 20:38:13.240 SERIAL » [ACK] (0x06) 20:38:13.242 DRIVER « [RES] [SendData] was sent: true 20:38:13.381 SERIAL « 0x010700137c00000f98 (9 bytes) 20:38:13.382 SERIAL » [ACK] (0x06) 20:38:13.382 DRIVER « [REQ] [SendData] callback id: 124 transmit status: OK 20:38:13.528 SERIAL « 0x0112000400130c590201084c6966656c696e658c (20 bytes) 20:38:13.529 CNTRLR [Node 019] [+] [Association Group Information] name[1]: "Lifeline" [internal] 20:38:13.529 SERIAL » [ACK] (0x06) 20:38:13.529 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 1 name: Lifeline 20:38:13.530 SERIAL » 0x010a00131803710109257ddc (12 bytes) 20:38:13.530 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 125 └─[NotificationCCEventSupportedGet] notification type: System 20:38:13.530 CNTRLR « [Node 019] Association group #1 has name "Lifeline" 20:38:13.530 CNTRLR » [Node 019] Association group #1: Querying info... 20:38:13.535 SERIAL « [ACK] (0x06) 20:38:13.536 SERIAL « 0x0104011301e8 (6 bytes) 20:38:13.536 SERIAL » [ACK] (0x06) 20:38:13.536 DRIVER « [RES] [SendData] was sent: true 20:38:15.044 SERIAL « 0x010700137d00009701 (9 bytes) 20:38:15.044 SERIAL » [ACK] (0x06) 20:38:15.045 DRIVER « [REQ] [SendData] callback id: 125 transmit status: OK 20:38:15.125 SERIAL « 0x010b000400180571020901089e (13 bytes) 20:38:15.125 CNTRLR [Node 024] [~] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" => "unknown" 20:38:15.126 CNTRLR [Node 024] [+] [Notification] supportedNotificationEvents[9]: 3 [internal] 20:38:15.126 CNTRLR [Node 024] [Notification] System[Hardware status]: metadata updat [Endpoint 0] ed 20:38:15.127 SERIAL » [ACK] (0x06) 20:38:15.127 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[NotificationCCEventSupportedReport] notification type: System supported events: · Unknown (0x03) 20:38:15.130 SERIAL » 0x010a00131a03590101257efd (12 bytes) 20:38:15.130 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 126 └─[AssociationGroupInfoCCNameGet] group id: 1 20:38:15.130 CNTRLR « [Node 024] received supported notification events for System: 3 20:38:15.130 CNTRLR [Node 024] [+] [Notification] interviewComplete: true [Endpoint 0] [internal] 20:38:15.133 SERIAL « [ACK] (0x06) 20:38:15.133 CNTRLR [Node 024] Interview stage completed: CommandClasses 20:38:15.134 CNTRLR [Node 024] Interview stage completed: OverwriteConfig 20:38:15.134 CNTRLR » [Node 024] requesting node neighbors... 20:38:15.135 SERIAL « 0x0104011301e8 (6 bytes) 20:38:15.135 SERIAL » [ACK] (0x06) 20:38:15.135 DRIVER « [RES] [SendData] was sent: true 20:38:15.214 SERIAL « 0x010700137e0000089d (9 bytes) 20:38:15.214 SERIAL » [ACK] (0x06) 20:38:15.215 DRIVER « [REQ] [SendData] callback id: 126 transmit status: OK 20:38:15.225 SERIAL « 0x01120004001a0c590201084c6966656c696e6585 (20 bytes) 20:38:15.226 CNTRLR [Node 026] [+] [Association Group Information] name[1]: "Lifeline" [internal] 20:38:15.226 SERIAL » [ACK] (0x06) 20:38:15.226 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 1 name: Lifeline 20:38:15.229 SERIAL » 0x010700801800000060 (9 bytes) 20:38:15.229 DRIVER » [Node 024] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 20:38:15.230 CNTRLR « [Node 026] Association group #1 has name "Lifeline" 20:38:15.230 CNTRLR » [Node 026] Association group #1: Querying info... 20:38:15.233 SERIAL « [ACK] (0x06) 20:38:15.233 SERIAL « 0x0120018035006e830000000000000000000000000000000000000000000000000 (34 bytes) 086 20:38:15.234 SERIAL » [ACK] (0x06) 20:38:15.234 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 5, 6, 18, 19, 20, 22, 23, 25, 26, 32 20:38:15.237 SERIAL » 0x010a00131c03590101257ffa (12 bytes) 20:38:15.238 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 127 └─[AssociationGroupInfoCCNameGet] group id: 1 20:38:15.238 CNTRLR « [Node 024] node neighbors received: 1, 3, 5, 6, 18, 19, 20, 22, 23, 25, 26, 32 20:38:15.238 CNTRLR [Node 024] Interview stage completed: Neighbors 20:38:15.238 CNTRLR [Node 024] Interview completed 20:38:15.239 CNTRLR [Node 024] The node is ready to be used 20:38:15.242 SERIAL « [ACK] (0x06) 20:38:15.243 SERIAL « 0x0104011301e8 (6 bytes) 20:38:15.244 SERIAL » [ACK] (0x06) 20:38:15.244 DRIVER « [RES] [SendData] was sent: true 20:38:15.303 SERIAL « 0x010700137f00000692 (9 bytes) 20:38:15.303 SERIAL » [ACK] (0x06) 20:38:15.304 DRIVER « [REQ] [SendData] callback id: 127 transmit status: OK 20:38:15.378 SERIAL « 0x01120004001c0c590201084c6966656c696e6583 (20 bytes) 20:38:15.379 CNTRLR [Node 028] [+] [Association Group Information] name[1]: "Lifeline" [internal] 20:38:15.379 SERIAL » [ACK] (0x06) 20:38:15.379 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 1 name: Lifeline 20:38:15.381 SERIAL » 0x010a00130303590102258019 (12 bytes) 20:38:15.381 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 128 └─[AssociationGroupInfoCCNameGet] group id: 2 20:38:15.381 CNTRLR « [Node 028] Association group #1 has name "Lifeline" 20:38:15.381 CNTRLR » [Node 028] Association group #1: Querying info... 20:38:15.383 SERIAL « [ACK] (0x06) 20:38:15.387 SERIAL « 0x0104011301e8 (6 bytes) 20:38:15.387 SERIAL » [ACK] (0x06) 20:38:15.387 DRIVER « [RES] [SendData] was sent: true 20:38:15.468 SERIAL « 0x010700138000000863 (9 bytes) 20:38:15.469 SERIAL » [ACK] (0x06) 20:38:15.470 DRIVER « [REQ] [SendData] callback id: 128 transmit status: OK 20:38:15.484 SERIAL « 0x011900040003135902020f4f6e2f4f66662028427574746f6e29f2 (27 bytes) 20:38:15.485 CNTRLR [Node 003] [+] [Association Group Information] name[2]: "On/Off (Bu [internal] tton)" 20:38:15.485 SERIAL » [ACK] (0x06) 20:38:15.486 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 2 name: On/Off (Button) 20:38:15.489 SERIAL » 0x010b001313045903000125810f (13 bytes) 20:38:15.489 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 129 └─[AssociationGroupInfoCCInfoGet] group id: 1 refresh cache: false 20:38:15.489 CNTRLR « [Node 003] Association group #2 has name "On/Off (Button)" 20:38:15.489 CNTRLR » [Node 003] Association group #2: Querying info... 20:38:15.492 SERIAL « [ACK] (0x06) 20:38:15.495 SERIAL « 0x0104011301e8 (6 bytes) 20:38:15.495 SERIAL » [ACK] (0x06) 20:38:15.496 DRIVER « [RES] [SendData] was sent: true 20:38:15.638 SERIAL « 0x010700138100000e64 (9 bytes) 20:38:15.638 SERIAL » [ACK] (0x06) 20:38:15.639 DRIVER « [REQ] [SendData] callback id: 129 transmit status: OK 20:38:15.775 SERIAL « 0x0110000400130a59040101000001000000ae (18 bytes) 20:38:15.776 CNTRLR [Node 019] [+] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false 20:38:15.776 CNTRLR [Node 019] [+] [Association Group Information] info[1]: [object Obj [internal] ect] 20:38:15.776 SERIAL » [ACK] (0x06) 20:38:15.777 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #1 mode: 0 profile: 1 event code: 0 20:38:15.779 SERIAL » 0x010b00131a0459030001258205 (13 bytes) 20:38:15.780 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 130 └─[AssociationGroupInfoCCInfoGet] group id: 1 refresh cache: false 20:38:15.780 CNTRLR « [Node 019] Received info for association group #1: info is dynamic: false profile: General: Lifeline 20:38:15.780 CNTRLR » [Node 019] Association group #1: Querying command list... 20:38:15.783 SERIAL « [ACK] (0x06) 20:38:15.785 SERIAL « 0x0104011301e8 (6 bytes) 20:38:15.786 SERIAL » [ACK] (0x06) 20:38:15.786 DRIVER « [RES] [SendData] was sent: true 20:38:15.904 SERIAL « 0x010700138200000c65 (9 bytes) 20:38:15.904 SERIAL » [ACK] (0x06) 20:38:15.905 DRIVER « [REQ] [SendData] callback id: 130 transmit status: OK 20:38:15.915 SERIAL « 0x01100004001a0a59040101000001000000a7 (18 bytes) 20:38:15.915 CNTRLR [Node 026] [+] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false 20:38:15.916 CNTRLR [Node 026] [+] [Association Group Information] info[1]: [object Obj [internal] ect] 20:38:15.916 SERIAL » [ACK] (0x06) 20:38:15.916 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #1 mode: 0 profile: 1 event code: 0 20:38:15.919 SERIAL » 0x010b00131c0459030001258302 (13 bytes) 20:38:15.920 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 131 └─[AssociationGroupInfoCCInfoGet] group id: 1 refresh cache: false 20:38:15.920 CNTRLR « [Node 026] Received info for association group #1: info is dynamic: false profile: General: Lifeline 20:38:15.920 CNTRLR » [Node 026] Association group #1: Querying command list... 20:38:15.922 SERIAL « [ACK] (0x06) 20:38:15.925 SERIAL « 0x0104011301e8 (6 bytes) 20:38:15.925 SERIAL » [ACK] (0x06) 20:38:15.926 DRIVER « [RES] [SendData] was sent: true 20:38:15.984 SERIAL « 0x01070013830000066e (9 bytes) 20:38:15.985 SERIAL » [ACK] (0x06) 20:38:15.986 DRIVER « [REQ] [SendData] callback id: 131 transmit status: OK 20:38:16.058 SERIAL « 0x01100004001c0a59040101000001000000a1 (18 bytes) 20:38:16.059 CNTRLR [Node 028] [+] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false 20:38:16.059 CNTRLR [Node 028] [+] [Association Group Information] info[1]: [object Obj [internal] ect] 20:38:16.059 SERIAL » [ACK] (0x06) 20:38:16.060 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #1 mode: 0 profile: 1 event code: 0 20:38:16.062 SERIAL » 0x010b0013030459030002258419 (13 bytes) 20:38:16.063 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 132 └─[AssociationGroupInfoCCInfoGet] group id: 2 refresh cache: false 20:38:16.063 CNTRLR « [Node 028] Received info for association group #1: info is dynamic: false profile: General: Lifeline 20:38:16.063 CNTRLR » [Node 028] Association group #1: Querying command list... 20:38:16.066 SERIAL « [ACK] (0x06) 20:38:16.068 SERIAL « 0x0104011301e8 (6 bytes) 20:38:16.069 SERIAL » [ACK] (0x06) 20:38:16.069 DRIVER « [RES] [SendData] was sent: true 20:38:16.149 SERIAL « 0x010700138400000867 (9 bytes) 20:38:16.149 SERIAL » [ACK] (0x06) 20:38:16.150 DRIVER « [REQ] [SendData] callback id: 132 transmit status: OK 20:38:16.163 SERIAL « 0x0110000400030a590401020020010000009d (18 bytes) 20:38:16.164 CNTRLR [Node 003] [~] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false => false 20:38:16.164 CNTRLR [Node 003] [+] [Association Group Information] info[2]: [object Obj [internal] ect] 20:38:16.164 SERIAL » [ACK] (0x06) 20:38:16.165 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #2 mode: 0 profile: 8193 event code: 0 20:38:16.170 SERIAL » 0x010b001313045905800125858d (13 bytes) 20:38:16.171 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 133 └─[AssociationGroupInfoCCCommandListGet] group id: 1 allow cache: true 20:38:16.171 CNTRLR « [Node 003] Received info for association group #2: info is dynamic: false profile: Control: Key 01 20:38:16.171 CNTRLR » [Node 003] Association group #2: Querying command list... 20:38:16.172 SERIAL « [ACK] (0x06) 20:38:16.176 SERIAL « 0x0104011301e8 (6 bytes) 20:38:16.176 SERIAL » [ACK] (0x06) 20:38:16.177 DRIVER « [RES] [SendData] was sent: true 20:38:16.320 SERIAL « 0x010700138500000f61 (9 bytes) 20:38:16.320 SERIAL » [ACK] (0x06) 20:38:16.321 DRIVER « [REQ] [SendData] callback id: 133 transmit status: OK 20:38:16.462 SERIAL « 0x0114000400130e5906010a5a012503320231057105ab (22 bytes) 20:38:16.463 CNTRLR [Node 019] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[1]: [object Map] 20:38:16.463 SERIAL » [ACK] (0x06) 20:38:16.464 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 1 commands: · Device Reset Locally: 0x01 · Binary Switch: 0x03 · Meter: 0x02 · Multilevel Sensor: 0x05 · Notification: 0x05 20:38:16.466 SERIAL » 0x010b00131a0459058001258687 (13 bytes) 20:38:16.467 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 134 └─[AssociationGroupInfoCCCommandListGet] group id: 1 allow cache: true 20:38:16.467 CNTRLR » [Node 019] Association group #2: Querying name... 20:38:16.469 SERIAL « [ACK] (0x06) 20:38:16.472 SERIAL « 0x0104011301e8 (6 bytes) 20:38:16.473 SERIAL » [ACK] (0x06) 20:38:16.473 DRIVER « [RES] [SendData] was sent: true 20:38:16.594 SERIAL « 0x010700138600000d60 (9 bytes) 20:38:16.594 SERIAL » [ACK] (0x06) 20:38:16.595 DRIVER « [REQ] [SendData] callback id: 134 transmit status: OK 20:38:16.605 SERIAL « 0x01140004001a0e5906010a5a012503320231057105a2 (22 bytes) 20:38:16.606 CNTRLR [Node 026] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[1]: [object Map] 20:38:16.606 SERIAL » [ACK] (0x06) 20:38:16.606 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 1 commands: · Device Reset Locally: 0x01 · Binary Switch: 0x03 · Meter: 0x02 · Multilevel Sensor: 0x05 · Notification: 0x05 20:38:16.609 SERIAL » 0x010b00131c0459058001258780 (13 bytes) 20:38:16.609 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 135 └─[AssociationGroupInfoCCCommandListGet] group id: 1 allow cache: true 20:38:16.609 CNTRLR » [Node 026] Association group #2: Querying name... 20:38:16.610 SERIAL « [ACK] (0x06) 20:38:16.615 SERIAL « 0x0104011301e8 (6 bytes) 20:38:16.615 SERIAL » [ACK] (0x06) 20:38:16.615 DRIVER « [RES] [SendData] was sent: true 20:38:16.674 SERIAL « 0x01070013870000066a (9 bytes) 20:38:16.674 SERIAL » [ACK] (0x06) 20:38:16.675 DRIVER « [REQ] [SendData] callback id: 135 transmit status: OK 20:38:16.749 SERIAL « 0x01140004001c0e5906010a5a012503320231057105a4 (22 bytes) 20:38:16.749 CNTRLR [Node 028] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[1]: [object Map] 20:38:16.751 SERIAL » [ACK] (0x06) 20:38:16.752 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 1 commands: · Device Reset Locally: 0x01 · Binary Switch: 0x03 · Meter: 0x02 · Multilevel Sensor: 0x05 · Notification: 0x05 20:38:16.753 SERIAL » 0x010b0013030459058002258893 (13 bytes) 20:38:16.753 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 136 └─[AssociationGroupInfoCCCommandListGet] group id: 2 allow cache: true 20:38:16.753 CNTRLR » [Node 028] Association group #2: Querying name... 20:38:16.754 SERIAL « [ACK] (0x06) 20:38:16.758 SERIAL « 0x0104011301e8 (6 bytes) 20:38:16.758 SERIAL » [ACK] (0x06) 20:38:16.758 DRIVER « [RES] [SendData] was sent: true 20:38:16.839 SERIAL « 0x01070013880000086b (9 bytes) 20:38:16.839 SERIAL » [ACK] (0x06) 20:38:16.840 DRIVER « [REQ] [SendData] callback id: 136 transmit status: OK 20:38:16.852 SERIAL « 0x010c00040003065906020220018c (14 bytes) 20:38:16.857 CNTRLR [Node 003] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[2]: [object Map] 20:38:16.857 SERIAL » [ACK] (0x06) 20:38:16.858 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 2 commands: · Basic: 0x01 20:38:16.865 SERIAL » 0x010a00131303590102258900 (12 bytes) 20:38:16.865 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 137 └─[AssociationGroupInfoCCNameGet] group id: 2 20:38:16.865 CNTRLR » [Node 003] Association group #3: Querying name... 20:38:16.869 SERIAL « [ACK] (0x06) 20:38:16.870 SERIAL « 0x0104011301e8 (6 bytes) 20:38:16.871 SERIAL » [ACK] (0x06) 20:38:16.872 DRIVER « [RES] [SendData] was sent: true 20:38:17.013 SERIAL « 0x010700138900000f6d (9 bytes) 20:38:17.013 SERIAL » [ACK] (0x06) 20:38:17.013 DRIVER « [REQ] [SendData] callback id: 137 transmit status: OK 20:38:17.171 SERIAL « 0x011900040013135902020f4f6e2f4f66662028427574746f6e29e2 (27 bytes) 20:38:17.172 CNTRLR [Node 019] [+] [Association Group Information] name[2]: "On/Off (Bu [internal] tton)" 20:38:17.172 SERIAL » [ACK] (0x06) 20:38:17.172 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 2 name: On/Off (Button) 20:38:17.175 SERIAL » 0x010a00131a03590102258a0a (12 bytes) 20:38:17.175 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 138 └─[AssociationGroupInfoCCNameGet] group id: 2 20:38:17.176 CNTRLR « [Node 019] Association group #2 has name "On/Off (Button)" 20:38:17.176 CNTRLR » [Node 019] Association group #2: Querying info... 20:38:17.178 SERIAL « [ACK] (0x06) 20:38:17.181 SERIAL « 0x0104011301e8 (6 bytes) 20:38:17.181 SERIAL » [ACK] (0x06) 20:38:17.182 DRIVER « [RES] [SendData] was sent: true 20:38:17.304 SERIAL « 0x010700138a00000d6c (9 bytes) 20:38:17.304 SERIAL » [ACK] (0x06) 20:38:17.305 DRIVER « [REQ] [SendData] callback id: 138 transmit status: OK 20:38:17.315 SERIAL « 0x01190004001a135902020f4f6e2f4f66662028427574746f6e29eb (27 bytes) 20:38:17.316 CNTRLR [Node 026] [+] [Association Group Information] name[2]: "On/Off (Bu [internal] tton)" 20:38:17.316 SERIAL » [ACK] (0x06) 20:38:17.317 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 2 name: On/Off (Button) 20:38:17.320 SERIAL » 0x010a00131c03590102258b0d (12 bytes) 20:38:17.320 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 139 └─[AssociationGroupInfoCCNameGet] group id: 2 20:38:17.320 CNTRLR « [Node 026] Association group #2 has name "On/Off (Button)" 20:38:17.320 CNTRLR » [Node 026] Association group #2: Querying info... 20:38:17.323 SERIAL « [ACK] (0x06) 20:38:17.326 SERIAL « 0x0104011301e8 (6 bytes) 20:38:17.326 SERIAL » [ACK] (0x06) 20:38:17.327 DRIVER « [RES] [SendData] was sent: true 20:38:17.385 SERIAL « 0x010700138b00000666 (9 bytes) 20:38:17.385 SERIAL » [ACK] (0x06) 20:38:17.386 DRIVER « [REQ] [SendData] callback id: 139 transmit status: OK 20:38:17.461 SERIAL « 0x01190004001c135902020f4f6e2f4f66662028427574746f6e29ed (27 bytes) 20:38:17.462 CNTRLR [Node 028] [+] [Association Group Information] name[2]: "On/Off (Bu [internal] tton)" 20:38:17.462 SERIAL » [ACK] (0x06) 20:38:17.462 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 2 name: On/Off (Button) 20:38:17.469 SERIAL » 0x010a00130303590103258c14 (12 bytes) 20:38:17.469 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 140 └─[AssociationGroupInfoCCNameGet] group id: 3 20:38:17.470 CNTRLR « [Node 028] Association group #2 has name "On/Off (Button)" 20:38:17.470 CNTRLR » [Node 028] Association group #2: Querying info... 20:38:17.472 SERIAL « [ACK] (0x06) 20:38:17.475 SERIAL « 0x0104011301e8 (6 bytes) 20:38:17.475 SERIAL » [ACK] (0x06) 20:38:17.476 DRIVER « [RES] [SendData] was sent: true 20:38:17.549 SERIAL « 0x010700138c00000760 (9 bytes) 20:38:17.549 SERIAL » [ACK] (0x06) 20:38:17.550 DRIVER « [REQ] [SendData] callback id: 140 transmit status: OK 20:38:17.564 SERIAL « 0x011800040003125902030e4f6e2f4f66662028506f776572299b (26 bytes) 20:38:17.565 CNTRLR [Node 003] [+] [Association Group Information] name[3]: "On/Off (Po [internal] wer)" 20:38:17.565 SERIAL » [ACK] (0x06) 20:38:17.566 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 3 name: On/Off (Power) 20:38:17.569 SERIAL » 0x010b0013130459030002258d00 (13 bytes) 20:38:17.569 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 141 └─[AssociationGroupInfoCCInfoGet] group id: 2 refresh cache: false 20:38:17.569 CNTRLR « [Node 003] Association group #3 has name "On/Off (Power)" 20:38:17.569 CNTRLR » [Node 003] Association group #3: Querying info... 20:38:17.572 SERIAL « [ACK] (0x06) 20:38:17.574 SERIAL « 0x0104011301e8 (6 bytes) 20:38:17.574 SERIAL » [ACK] (0x06) 20:38:17.575 DRIVER « [RES] [SendData] was sent: true 20:38:17.718 SERIAL « 0x010700138d00000e68 (9 bytes) 20:38:17.718 SERIAL » [ACK] (0x06) 20:38:17.719 DRIVER « [REQ] [SendData] callback id: 141 transmit status: OK 20:38:17.855 SERIAL « 0x0110000400130a590401020020010000008d (18 bytes) 20:38:17.856 CNTRLR [Node 019] [~] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false => false 20:38:17.856 CNTRLR [Node 019] [+] [Association Group Information] info[2]: [object Obj [internal] ect] 20:38:17.856 SERIAL » [ACK] (0x06) 20:38:17.857 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #2 mode: 0 profile: 8193 event code: 0 20:38:17.859 SERIAL » 0x010b00131a0459030002258e0a (13 bytes) 20:38:17.860 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 142 └─[AssociationGroupInfoCCInfoGet] group id: 2 refresh cache: false 20:38:17.860 CNTRLR « [Node 019] Received info for association group #2: info is dynamic: false profile: Control: Key 01 20:38:17.860 CNTRLR » [Node 019] Association group #2: Querying command list... 20:38:17.861 SERIAL « [ACK] (0x06) 20:38:17.865 SERIAL « 0x0104011301e8 (6 bytes) 20:38:17.865 SERIAL » [ACK] (0x06) 20:38:17.866 DRIVER « [RES] [SendData] was sent: true 20:38:17.984 SERIAL « 0x010700138e00000c69 (9 bytes) 20:38:17.984 SERIAL » [ACK] (0x06) 20:38:17.985 DRIVER « [REQ] [SendData] callback id: 142 transmit status: OK 20:38:17.995 SERIAL « 0x01100004001a0a5904010200200100000084 (18 bytes) 20:38:17.995 CNTRLR [Node 026] [~] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false => false 20:38:17.996 CNTRLR [Node 026] [+] [Association Group Information] info[2]: [object Obj [internal] ect] 20:38:17.996 SERIAL » [ACK] (0x06) 20:38:17.996 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #2 mode: 0 profile: 8193 event code: 0 20:38:17.999 SERIAL » 0x010b00131c0459030002258f0d (13 bytes) 20:38:17.999 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 143 └─[AssociationGroupInfoCCInfoGet] group id: 2 refresh cache: false 20:38:18.000 CNTRLR « [Node 026] Received info for association group #2: info is dynamic: false profile: Control: Key 01 20:38:18.000 CNTRLR » [Node 026] Association group #2: Querying command list... 20:38:18.002 SERIAL « [ACK] (0x06) 20:38:18.005 SERIAL « 0x0104011301e8 (6 bytes) 20:38:18.005 SERIAL » [ACK] (0x06) 20:38:18.006 DRIVER « [RES] [SendData] was sent: true 20:38:18.064 SERIAL « 0x010700138f00000662 (9 bytes) 20:38:18.065 SERIAL » [ACK] (0x06) 20:38:18.065 DRIVER « [REQ] [SendData] callback id: 143 transmit status: OK 20:38:18.138 SERIAL « 0x01100004001c0a5904010200200100000082 (18 bytes) 20:38:18.139 CNTRLR [Node 028] [~] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false => false 20:38:18.139 CNTRLR [Node 028] [+] [Association Group Information] info[2]: [object Obj [internal] ect] 20:38:18.139 SERIAL » [ACK] (0x06) 20:38:18.140 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #2 mode: 0 profile: 8193 event code: 0 20:38:18.142 SERIAL » 0x010b001303045903000325900c (13 bytes) 20:38:18.143 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 144 └─[AssociationGroupInfoCCInfoGet] group id: 3 refresh cache: false 20:38:18.143 CNTRLR « [Node 028] Received info for association group #2: info is dynamic: false profile: Control: Key 01 20:38:18.143 CNTRLR » [Node 028] Association group #2: Querying command list... 20:38:18.144 SERIAL « [ACK] (0x06) 20:38:18.148 SERIAL « 0x0104011301e8 (6 bytes) 20:38:18.148 SERIAL » [ACK] (0x06) 20:38:18.148 DRIVER « [RES] [SendData] was sent: true 20:38:18.229 SERIAL « 0x010700139000000873 (9 bytes) 20:38:18.229 SERIAL » [ACK] (0x06) 20:38:18.231 DRIVER « [REQ] [SendData] callback id: 144 transmit status: OK 20:38:18.243 SERIAL « 0x0110000400030a5904010300310400000088 (18 bytes) 20:38:18.244 CNTRLR [Node 003] [~] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false => false 20:38:18.244 CNTRLR [Node 003] [+] [Association Group Information] info[3]: [object Obj [internal] ect] 20:38:18.244 SERIAL » [ACK] (0x06) 20:38:18.245 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #3 mode: 0 profile: 12548 event code: 0 20:38:18.247 SERIAL » 0x010b001313045905800225919a (13 bytes) 20:38:18.248 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 145 └─[AssociationGroupInfoCCCommandListGet] group id: 2 allow cache: true 20:38:18.248 CNTRLR « [Node 003] Received info for association group #3: info is dynamic: false profile: Sensor: Power 20:38:18.248 CNTRLR » [Node 003] Association group #3: Querying command list... 20:38:18.250 SERIAL « [ACK] (0x06) 20:38:18.253 SERIAL « 0x0104011301e8 (6 bytes) 20:38:18.253 SERIAL » [ACK] (0x06) 20:38:18.254 DRIVER « [RES] [SendData] was sent: true 20:38:18.491 SERIAL « 0x010700139100001862 (9 bytes) 20:38:18.492 SERIAL » [ACK] (0x06) 20:38:18.492 DRIVER « [REQ] [SendData] callback id: 145 transmit status: OK 20:38:18.618 SERIAL « 0x010c00040013065906020220019c (14 bytes) 20:38:18.619 CNTRLR [Node 019] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[2]: [object Map] 20:38:18.619 SERIAL » [ACK] (0x06) 20:38:18.620 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 2 commands: · Basic: 0x01 20:38:18.622 SERIAL » 0x010b00131a0459058002259290 (13 bytes) 20:38:18.623 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 146 └─[AssociationGroupInfoCCCommandListGet] group id: 2 allow cache: true 20:38:18.623 CNTRLR » [Node 019] Association group #3: Querying name... 20:38:18.625 SERIAL « [ACK] (0x06) 20:38:18.628 SERIAL « 0x0104011301e8 (6 bytes) 20:38:18.629 SERIAL » [ACK] (0x06) 20:38:18.629 DRIVER « [RES] [SendData] was sent: true 20:38:18.754 SERIAL « 0x010700139200000d74 (9 bytes) 20:38:18.754 SERIAL » [ACK] (0x06) 20:38:18.755 DRIVER « [REQ] [SendData] callback id: 146 transmit status: OK 20:38:18.776 SERIAL « 0x010c0004001a0659060202200195 (14 bytes) 20:38:18.777 CNTRLR [Node 026] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[2]: [object Map] 20:38:18.777 SERIAL » [ACK] (0x06) 20:38:18.781 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 2 commands: · Basic: 0x01 20:38:18.790 SERIAL » 0x010b00131c0459058002259397 (13 bytes) 20:38:18.795 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 147 └─[AssociationGroupInfoCCCommandListGet] group id: 2 allow cache: true 20:38:18.795 CNTRLR » [Node 026] Association group #3: Querying name... 20:38:18.800 SERIAL « [ACK] (0x06) 20:38:18.803 SERIAL « 0x0104011301e8 (6 bytes) 20:38:18.803 SERIAL » [ACK] (0x06) 20:38:18.804 DRIVER « [RES] [SendData] was sent: true 20:38:18.859 SERIAL « 0x01070013930000067e (9 bytes) 20:38:18.859 SERIAL » [ACK] (0x06) 20:38:18.859 DRIVER « [REQ] [SendData] callback id: 147 transmit status: OK 20:38:18.937 SERIAL « 0x010c0004001c0659060202200193 (14 bytes) 20:38:18.938 CNTRLR [Node 028] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[2]: [object Map] 20:38:18.938 SERIAL » [ACK] (0x06) 20:38:18.939 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 2 commands: · Basic: 0x01 20:38:18.941 SERIAL » 0x010b001303045905800325948e (13 bytes) 20:38:18.942 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 148 └─[AssociationGroupInfoCCCommandListGet] group id: 3 allow cache: true 20:38:18.942 CNTRLR » [Node 028] Association group #3: Querying name... 20:38:18.945 SERIAL « [ACK] (0x06) 20:38:18.947 SERIAL « 0x0104011301e8 (6 bytes) 20:38:18.948 SERIAL » [ACK] (0x06) 20:38:18.948 DRIVER « [RES] [SendData] was sent: true 20:38:19.029 SERIAL « 0x010700139400000877 (9 bytes) 20:38:19.029 SERIAL » [ACK] (0x06) 20:38:19.030 DRIVER « [REQ] [SendData] callback id: 148 transmit status: OK 20:38:19.081 SERIAL « 0x010c00040003065906030220018d (14 bytes) 20:38:19.082 CNTRLR [Node 003] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[3]: [object Map] 20:38:19.082 SERIAL » [ACK] (0x06) 20:38:19.083 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 3 commands: · Basic: 0x01 20:38:19.085 SERIAL » 0x010a0013130359010325951d (12 bytes) 20:38:19.086 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 149 └─[AssociationGroupInfoCCNameGet] group id: 3 20:38:19.086 CNTRLR [Node 003] [+] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true 20:38:19.101 SERIAL « [ACK] (0x06) 20:38:19.103 SERIAL « 0x0104011301e8 (6 bytes) 20:38:19.103 SERIAL » [ACK] (0x06) 20:38:19.104 DRIVER « [RES] [SendData] was sent: true 20:38:19.105 CNTRLR [Node 003] NotificationCC: doing a complete interview... 20:38:19.105 CNTRLR » [Node 003] querying supported notification types... 20:38:19.233 SERIAL « 0x010700139500000f71 (9 bytes) 20:38:19.234 SERIAL » [ACK] (0x06) 20:38:19.234 DRIVER « [REQ] [SendData] callback id: 149 transmit status: OK 20:38:19.389 SERIAL « 0x011800040013125902030e4f6e2f4f66662028506f776572298b (26 bytes) 20:38:19.390 CNTRLR [Node 019] [+] [Association Group Information] name[3]: "On/Off (Po [internal] wer)" 20:38:19.390 SERIAL » [ACK] (0x06) 20:38:19.391 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 3 name: On/Off (Power) 20:38:19.393 SERIAL » 0x010a00131a03590103259617 (12 bytes) 20:38:19.394 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 150 └─[AssociationGroupInfoCCNameGet] group id: 3 20:38:19.394 CNTRLR « [Node 019] Association group #3 has name "On/Off (Power)" 20:38:19.394 CNTRLR » [Node 019] Association group #3: Querying info... 20:38:19.398 SERIAL « [ACK] (0x06) 20:38:19.399 SERIAL « 0x0104011301e8 (6 bytes) 20:38:19.399 SERIAL » [ACK] (0x06) 20:38:19.400 DRIVER « [RES] [SendData] was sent: true 20:38:19.524 SERIAL « 0x010700139600000d70 (9 bytes) 20:38:19.524 SERIAL » [ACK] (0x06) 20:38:19.525 DRIVER « [REQ] [SendData] callback id: 150 transmit status: OK 20:38:19.536 SERIAL « 0x01180004001a125902030e4f6e2f4f66662028506f7765722982 (26 bytes) 20:38:19.536 CNTRLR [Node 026] [+] [Association Group Information] name[3]: "On/Off (Po [internal] wer)" 20:38:19.537 SERIAL » [ACK] (0x06) 20:38:19.537 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 3 name: On/Off (Power) 20:38:19.540 SERIAL » 0x010a00131c03590103259710 (12 bytes) 20:38:19.540 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 151 └─[AssociationGroupInfoCCNameGet] group id: 3 20:38:19.540 CNTRLR « [Node 026] Association group #3 has name "On/Off (Power)" 20:38:19.540 CNTRLR » [Node 026] Association group #3: Querying info... 20:38:19.543 SERIAL « [ACK] (0x06) 20:38:19.545 SERIAL « 0x0104011301e8 (6 bytes) 20:38:19.546 SERIAL » [ACK] (0x06) 20:38:19.546 DRIVER « [RES] [SendData] was sent: true 20:38:19.604 SERIAL « 0x01070013970000067a (9 bytes) 20:38:19.605 SERIAL » [ACK] (0x06) 20:38:19.605 DRIVER « [REQ] [SendData] callback id: 151 transmit status: OK 20:38:19.680 SERIAL « 0x01180004001c125902030e4f6e2f4f66662028506f7765722984 (26 bytes) 20:38:19.681 CNTRLR [Node 028] [+] [Association Group Information] name[3]: "On/Off (Po [internal] wer)" 20:38:19.681 SERIAL » [ACK] (0x06) 20:38:19.682 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 3 name: On/Off (Power) 20:38:19.684 SERIAL » 0x010900130302710725982f (11 bytes) 20:38:19.684 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 152 └─[NotificationCCSupportedGet] 20:38:19.685 CNTRLR « [Node 028] Association group #3 has name "On/Off (Power)" 20:38:19.685 CNTRLR » [Node 028] Association group #3: Querying info... 20:38:19.687 SERIAL « [ACK] (0x06) 20:38:19.690 SERIAL « 0x0104011301e8 (6 bytes) 20:38:19.690 SERIAL » [ACK] (0x06) 20:38:19.690 DRIVER « [RES] [SendData] was sent: true 20:38:19.768 SERIAL « 0x01070013980000087b (9 bytes) 20:38:19.769 SERIAL » [ACK] (0x06) 20:38:19.769 DRIVER « [REQ] [SendData] callback id: 152 transmit status: OK 20:38:19.781 SERIAL « 0x010b000400030571080200018c (13 bytes) 20:38:19.782 CNTRLR [Node 003] [+] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" 20:38:19.782 CNTRLR [Node 003] [+] [Notification] supportedNotificationTyp [Endpoint 0] [internal] es: 8 20:38:19.782 CNTRLR [Node 003] [+] [Notification] supportsV1Alarm: false [Endpoint 0] [internal] 20:38:19.783 CNTRLR [Node 003] [~] [Notification] supportedNotificationTyp [Endpoint 0] [internal] es: 8 => 8 20:38:19.783 SERIAL » [ACK] (0x06) 20:38:19.783 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[NotificationCCSupportedReport] supports V1 alarm: false supported notification types: · Power Management 20:38:19.786 SERIAL » 0x010b0013130459030003259915 (13 bytes) 20:38:19.786 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 153 └─[AssociationGroupInfoCCInfoGet] group id: 3 refresh cache: false 20:38:19.787 CNTRLR « [Node 003] received supported notification types: · Power Management 20:38:19.787 CNTRLR » [Node 003] querying supported notification events for Power Management... 20:38:19.789 SERIAL « [ACK] (0x06) 20:38:19.792 SERIAL « 0x0104011301e8 (6 bytes) 20:38:19.792 SERIAL » [ACK] (0x06) 20:38:19.793 DRIVER « [RES] [SendData] was sent: true 20:38:19.935 SERIAL « 0x010700139900000f7d (9 bytes) 20:38:19.935 SERIAL » [ACK] (0x06) 20:38:19.936 DRIVER « [REQ] [SendData] callback id: 153 transmit status: OK 20:38:20.075 SERIAL « 0x0110000400130a5904010300310400000098 (18 bytes) 20:38:20.076 CNTRLR [Node 019] [~] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false => false 20:38:20.076 CNTRLR [Node 019] [+] [Association Group Information] info[3]: [object Obj [internal] ect] 20:38:20.076 SERIAL » [ACK] (0x06) 20:38:20.077 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #3 mode: 0 profile: 12548 event code: 0 20:38:20.080 SERIAL » 0x010b00131a0459030003259a1f (13 bytes) 20:38:20.080 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 154 └─[AssociationGroupInfoCCInfoGet] group id: 3 refresh cache: false 20:38:20.080 CNTRLR « [Node 019] Received info for association group #3: info is dynamic: false profile: Sensor: Power 20:38:20.080 CNTRLR » [Node 019] Association group #3: Querying command list... 20:38:20.081 SERIAL « [ACK] (0x06) 20:38:20.085 SERIAL « 0x0104011301e8 (6 bytes) 20:38:20.085 SERIAL » [ACK] (0x06) 20:38:20.085 DRIVER « [RES] [SendData] was sent: true 20:38:20.204 SERIAL « 0x010700139a00000c7d (9 bytes) 20:38:20.204 SERIAL » [ACK] (0x06) 20:38:20.205 DRIVER « [REQ] [SendData] callback id: 154 transmit status: OK 20:38:20.215 SERIAL « 0x01100004001a0a5904010300310400000091 (18 bytes) 20:38:20.215 CNTRLR [Node 026] [~] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false => false 20:38:20.216 CNTRLR [Node 026] [+] [Association Group Information] info[3]: [object Obj [internal] ect] 20:38:20.216 SERIAL » [ACK] (0x06) 20:38:20.217 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #3 mode: 0 profile: 12548 event code: 0 20:38:20.222 SERIAL » 0x010b00131c0459030003259b18 (13 bytes) 20:38:20.222 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 155 └─[AssociationGroupInfoCCInfoGet] group id: 3 refresh cache: false 20:38:20.223 CNTRLR « [Node 026] Received info for association group #3: info is dynamic: false profile: Sensor: Power 20:38:20.223 CNTRLR » [Node 026] Association group #3: Querying command list... 20:38:20.226 SERIAL « [ACK] (0x06) 20:38:20.228 SERIAL « 0x0104011301e8 (6 bytes) 20:38:20.228 SERIAL » [ACK] (0x06) 20:38:20.228 DRIVER « [RES] [SendData] was sent: true 20:38:20.287 SERIAL « 0x010700139b00000676 (9 bytes) 20:38:20.288 SERIAL » [ACK] (0x06) 20:38:20.288 DRIVER « [REQ] [SendData] callback id: 155 transmit status: OK 20:38:20.368 SERIAL « 0x01100004001c0a5904010300310400000097 (18 bytes) 20:38:20.369 CNTRLR [Node 028] [~] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false => false 20:38:20.369 CNTRLR [Node 028] [+] [Association Group Information] info[3]: [object Obj [internal] ect] 20:38:20.369 SERIAL » [ACK] (0x06) 20:38:20.370 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #3 mode: 0 profile: 12548 event code: 0 20:38:20.373 SERIAL » 0x010a00130303710108259c27 (12 bytes) 20:38:20.373 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 156 └─[NotificationCCEventSupportedGet] notification type: Power Management 20:38:20.374 CNTRLR « [Node 028] Received info for association group #3: info is dynamic: false profile: Sensor: Power 20:38:20.374 CNTRLR » [Node 028] Association group #3: Querying command list... 20:38:20.377 SERIAL « [ACK] (0x06) 20:38:20.379 SERIAL « 0x0104011301e8 (6 bytes) 20:38:20.379 SERIAL » [ACK] (0x06) 20:38:20.379 DRIVER « [RES] [SendData] was sent: true 20:38:20.461 SERIAL « 0x010c0004000306710208024001ca (14 bytes) 20:38:20.462 CNTRLR [Node 003] [~] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" => "unknown" 20:38:20.463 CNTRLR [Node 003] [+] [Notification] supportedNotificationEvents[8]: 6,8 [internal] 20:38:20.463 CNTRLR [Node 003] [Notification] Power Management[Over-current status]: [Endpoint 0] metadata updated 20:38:20.464 CNTRLR [Node 003] [Notification] Power Management[Over-load status]: met [Endpoint 0] adata updated 20:38:20.465 SERIAL » [ACK] (0x06) 20:38:20.465 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[NotificationCCEventSupportedReport] notification type: Power Management supported events: · Unknown (0x06) · Unknown (0x08) 20:38:20.503 SERIAL « 0x010700139c00000d7a (9 bytes) 20:38:20.503 SERIAL » [ACK] (0x06) 20:38:20.504 DRIVER « [REQ] [SendData] callback id: 156 transmit status: OK 20:38:20.516 SERIAL « 0x010c0004000306710208024001ca (14 bytes) 20:38:20.516 CNTRLR [Node 003] [~] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" => "unknown" 20:38:20.517 CNTRLR [Node 003] [~] [Notification] supportedNotificationEvents[8]: 6,8 = [internal] > 6,8 20:38:20.517 CNTRLR [Node 003] [Notification] Power Management[Over-current status]: [Endpoint 0] metadata updated 20:38:20.518 CNTRLR [Node 003] [Notification] Power Management[Over-load status]: met [Endpoint 0] adata updated 20:38:20.518 SERIAL » [ACK] (0x06) 20:38:20.519 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[NotificationCCEventSupportedReport] notification type: Power Management supported events: · Unknown (0x06) · Unknown (0x08) 20:38:20.522 SERIAL » 0x010b0013130459058003259d97 (13 bytes) 20:38:20.523 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 157 └─[AssociationGroupInfoCCCommandListGet] group id: 3 allow cache: true 20:38:20.523 CNTRLR « [Node 003] received supported notification events for Power Management: 6, 8 20:38:20.523 CNTRLR [Node 003] [+] [Notification] interviewComplete: true [Endpoint 0] [internal] 20:38:20.528 SERIAL « [ACK] (0x06) 20:38:20.530 SERIAL « 0x0104011301e8 (6 bytes) 20:38:20.530 SERIAL » [ACK] (0x06) 20:38:20.531 DRIVER « [RES] [SendData] was sent: true 20:38:20.532 CNTRLR [Node 003] Interview stage completed: CommandClasses 20:38:20.532 CNTRLR [Node 003] Interview stage completed: OverwriteConfig 20:38:20.532 CNTRLR » [Node 003] requesting node neighbors... 20:38:20.672 SERIAL « 0x010700139d00000f79 (9 bytes) 20:38:20.672 SERIAL » [ACK] (0x06) 20:38:20.673 DRIVER « [REQ] [SendData] callback id: 157 transmit status: OK 20:38:20.798 SERIAL « 0x010c00040013065906030220019d (14 bytes) 20:38:20.799 CNTRLR [Node 019] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[3]: [object Map] 20:38:20.800 SERIAL » [ACK] (0x06) 20:38:20.800 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 3 commands: · Basic: 0x01 20:38:20.803 SERIAL » 0x01070080030000007b (9 bytes) 20:38:20.803 DRIVER » [Node 003] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 20:38:20.804 CNTRLR [Node 019] [+] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true 20:38:20.804 CNTRLR [Node 019] NotificationCC: doing a complete interview... 20:38:20.804 CNTRLR » [Node 019] querying supported notification types... 20:38:20.807 SERIAL « [ACK] (0x06) 20:38:20.808 SERIAL « 0x01200180f3cddf8b0000000000000000000000000000000000000000000000000 (34 bytes) 034 20:38:20.808 SERIAL » [ACK] (0x06) 20:38:20.809 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 2, 5, 6, 7, 8, 9, 11, 12, 15, 16, 17, 18, 19, 20, 21, 23, 24, 2 5, 26, 28, 32 20:38:20.813 SERIAL » 0x010b00131a0459058003259e9d (13 bytes) 20:38:20.814 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 158 └─[AssociationGroupInfoCCCommandListGet] group id: 3 allow cache: true 20:38:20.814 CNTRLR « [Node 003] node neighbors received: 1, 2, 5, 6, 7, 8, 9, 11, 12, 15, 16, 17, 18, 19, 20, 21, 23, 24, 25, 26, 28, 32 20:38:20.814 CNTRLR [Node 003] Interview stage completed: Neighbors 20:38:20.814 CNTRLR [Node 003] Interview completed 20:38:20.815 CNTRLR [Node 003] The node is ready to be used 20:38:20.820 SERIAL « [ACK] (0x06) 20:38:20.821 SERIAL « 0x0104011301e8 (6 bytes) 20:38:20.821 SERIAL » [ACK] (0x06) 20:38:20.822 DRIVER « [RES] [SendData] was sent: true 20:38:20.898 SERIAL « 0x010c0004001a06310504220610ef (14 bytes) 20:38:20.899 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:38:20.899 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 215.6 => 155.2 [Endpoint 0] 20:38:20.899 SERIAL » [ACK] (0x06) 20:38:20.900 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 155.2 20:38:20.940 SERIAL « 0x010700139e00000d78 (9 bytes) 20:38:20.940 SERIAL » [ACK] (0x06) 20:38:20.941 DRIVER « [REQ] [SendData] callback id: 158 transmit status: OK 20:38:20.950 SERIAL « 0x010c0004001a0659060302200194 (14 bytes) 20:38:20.951 CNTRLR [Node 026] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[3]: [object Map] 20:38:20.951 SERIAL » [ACK] (0x06) 20:38:20.951 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 3 commands: · Basic: 0x01 20:38:20.952 SERIAL » 0x010b00131c0459058003259f9a (13 bytes) 20:38:20.952 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 159 └─[AssociationGroupInfoCCCommandListGet] group id: 3 allow cache: true 20:38:20.953 CNTRLR [Node 026] [+] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true 20:38:20.956 SERIAL « [ACK] (0x06) 20:38:20.957 CNTRLR [Node 026] NotificationCC: doing a complete interview... 20:38:20.957 CNTRLR » [Node 026] querying supported notification types... 20:38:20.958 SERIAL « 0x0104011301e8 (6 bytes) 20:38:20.958 SERIAL » [ACK] (0x06) 20:38:20.959 DRIVER « [RES] [SendData] was sent: true 20:38:21.017 SERIAL « 0x010700139f00000672 (9 bytes) 20:38:21.017 SERIAL » [ACK] (0x06) 20:38:21.017 DRIVER « [REQ] [SendData] callback id: 159 transmit status: OK 20:38:21.097 SERIAL « 0x010c0004001c0659060302200192 (14 bytes) 20:38:21.098 CNTRLR [Node 028] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[3]: [object Map] 20:38:21.098 SERIAL » [ACK] (0x06) 20:38:21.098 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 3 commands: · Basic: 0x01 20:38:21.101 SERIAL » 0x010900131302710725a007 (11 bytes) 20:38:21.102 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 160 └─[NotificationCCSupportedGet] 20:38:21.102 CNTRLR [Node 028] [+] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true 20:38:21.103 CNTRLR [Node 028] NotificationCC: doing a complete interview... 20:38:21.103 CNTRLR » [Node 028] querying supported notification types... 20:38:21.105 SERIAL « [ACK] (0x06) 20:38:21.107 SERIAL « 0x0104011301e8 (6 bytes) 20:38:21.107 SERIAL » [ACK] (0x06) 20:38:21.108 DRIVER « [RES] [SendData] was sent: true 20:38:21.309 SERIAL « 0x01070013a00000145f (9 bytes) 20:38:21.309 SERIAL » [ACK] (0x06) 20:38:21.310 DRIVER « [REQ] [SendData] callback id: 160 transmit status: OK 20:38:21.436 SERIAL « 0x010b000400130571080200019c (13 bytes) 20:38:21.437 CNTRLR [Node 019] [+] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" 20:38:21.438 CNTRLR [Node 019] [+] [Notification] supportedNotificationTyp [Endpoint 0] [internal] es: 8 20:38:21.438 CNTRLR [Node 019] [+] [Notification] supportsV1Alarm: false [Endpoint 0] [internal] 20:38:21.438 CNTRLR [Node 019] [~] [Notification] supportedNotificationTyp [Endpoint 0] [internal] es: 8 => 8 20:38:21.439 SERIAL » [ACK] (0x06) 20:38:21.439 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[NotificationCCSupportedReport] supports V1 alarm: false supported notification types: · Power Management 20:38:21.441 SERIAL » 0x010900131a02710725a10f (11 bytes) 20:38:21.441 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 161 └─[NotificationCCSupportedGet] 20:38:21.441 CNTRLR « [Node 019] received supported notification types: · Power Management 20:38:21.441 CNTRLR » [Node 019] querying supported notification events for Power Management... 20:38:21.442 SERIAL « [ACK] (0x06) 20:38:21.446 SERIAL « 0x0104011301e8 (6 bytes) 20:38:21.446 SERIAL » [ACK] (0x06) 20:38:21.447 DRIVER « [RES] [SendData] was sent: true 20:38:21.564 SERIAL « 0x01070013a100000c46 (9 bytes) 20:38:21.564 SERIAL » [ACK] (0x06) 20:38:21.565 DRIVER « [REQ] [SendData] callback id: 161 transmit status: OK 20:38:21.574 SERIAL « 0x010b0004001a05710802000195 (13 bytes) 20:38:21.575 CNTRLR [Node 026] [+] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" 20:38:21.575 CNTRLR [Node 026] [+] [Notification] supportedNotificationTyp [Endpoint 0] [internal] es: 8 20:38:21.575 CNTRLR [Node 026] [+] [Notification] supportsV1Alarm: false [Endpoint 0] [internal] 20:38:21.576 CNTRLR [Node 026] [~] [Notification] supportedNotificationTyp [Endpoint 0] [internal] es: 8 => 8 20:38:21.576 SERIAL » [ACK] (0x06) 20:38:21.576 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[NotificationCCSupportedReport] supports V1 alarm: false supported notification types: · Power Management 20:38:21.579 SERIAL » 0x010900131c02710725a20a (11 bytes) 20:38:21.580 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 162 └─[NotificationCCSupportedGet] 20:38:21.580 CNTRLR « [Node 026] received supported notification types: · Power Management 20:38:21.580 CNTRLR » [Node 026] querying supported notification events for Power Management... 20:38:21.583 SERIAL « [ACK] (0x06) 20:38:21.585 SERIAL « 0x0104011301e8 (6 bytes) 20:38:21.585 SERIAL » [ACK] (0x06) 20:38:21.586 DRIVER « [RES] [SendData] was sent: true 20:38:21.643 SERIAL « 0x01070013a20000064f (9 bytes) 20:38:21.644 SERIAL » [ACK] (0x06) 20:38:21.644 DRIVER « [REQ] [SendData] callback id: 162 transmit status: OK 20:38:21.716 SERIAL « 0x010b0004001c05710802000193 (13 bytes) 20:38:21.717 CNTRLR [Node 028] [+] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" 20:38:21.717 CNTRLR [Node 028] [+] [Notification] supportedNotificationTyp [Endpoint 0] [internal] es: 8 20:38:21.718 CNTRLR [Node 028] [+] [Notification] supportsV1Alarm: false [Endpoint 0] [internal] 20:38:21.718 CNTRLR [Node 028] [~] [Notification] supportedNotificationTyp [Endpoint 0] [internal] es: 8 => 8 20:38:21.718 SERIAL » [ACK] (0x06) 20:38:21.719 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[NotificationCCSupportedReport] supports V1 alarm: false supported notification types: · Power Management 20:38:21.722 SERIAL » 0x010a0013130371010825a308 (12 bytes) 20:38:21.722 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 163 └─[NotificationCCEventSupportedGet] notification type: Power Management 20:38:21.723 CNTRLR « [Node 028] received supported notification types: · Power Management 20:38:21.723 CNTRLR » [Node 028] querying supported notification events for Power Management... 20:38:21.725 SERIAL « [ACK] (0x06) 20:38:21.728 SERIAL « 0x0104011301e8 (6 bytes) 20:38:21.728 SERIAL » [ACK] (0x06) 20:38:21.728 DRIVER « [RES] [SendData] was sent: true 20:38:21.931 SERIAL « 0x01070013a30000155d (9 bytes) 20:38:21.931 SERIAL » [ACK] (0x06) 20:38:21.932 DRIVER « [REQ] [SendData] callback id: 163 transmit status: OK 20:38:22.058 SERIAL « 0x010c0004001306710208024001da (14 bytes) 20:38:22.059 CNTRLR [Node 019] [~] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" => "unknown" 20:38:22.059 CNTRLR [Node 019] [+] [Notification] supportedNotificationEvents[8]: 6,8 [internal] 20:38:22.060 CNTRLR [Node 019] [Notification] Power Management[Over-current status]: [Endpoint 0] metadata updated 20:38:22.060 CNTRLR [Node 019] [Notification] Power Management[Over-load status]: met [Endpoint 0] adata updated 20:38:22.061 SERIAL » [ACK] (0x06) 20:38:22.062 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[NotificationCCEventSupportedReport] notification type: Power Management supported events: · Unknown (0x06) · Unknown (0x08) 20:38:22.065 SERIAL » 0x010a00131a0371010825a406 (12 bytes) 20:38:22.065 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 164 └─[NotificationCCEventSupportedGet] notification type: Power Management 20:38:22.065 CNTRLR « [Node 019] received supported notification events for Power Management: 6, 8 20:38:22.066 CNTRLR [Node 019] [+] [Notification] interviewComplete: true [Endpoint 0] [internal] 20:38:22.071 SERIAL « [ACK] (0x06) 20:38:22.076 SERIAL « 0x0104011301e8 (6 bytes) 20:38:22.077 SERIAL » [ACK] (0x06) 20:38:22.077 DRIVER « [RES] [SendData] was sent: true 20:38:22.079 CNTRLR [Node 019] Interview stage completed: CommandClasses 20:38:22.079 CNTRLR [Node 019] Interview stage completed: OverwriteConfig 20:38:22.079 CNTRLR » [Node 019] requesting node neighbors... 20:38:22.194 SERIAL « 0x01070013a400000d42 (9 bytes) 20:38:22.195 SERIAL » [ACK] (0x06) 20:38:22.195 DRIVER « [REQ] [SendData] callback id: 164 transmit status: OK 20:38:22.204 SERIAL « 0x010c0004001a06710208024001d3 (14 bytes) 20:38:22.205 CNTRLR [Node 026] [~] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" => "unknown" 20:38:22.205 CNTRLR [Node 026] [+] [Notification] supportedNotificationEvents[8]: 6,8 [internal] 20:38:22.206 CNTRLR [Node 026] [Notification] Power Management[Over-current status]: [Endpoint 0] metadata updated 20:38:22.206 CNTRLR [Node 026] [Notification] Power Management[Over-load status]: met [Endpoint 0] adata updated 20:38:22.207 SERIAL » [ACK] (0x06) 20:38:22.207 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[NotificationCCEventSupportedReport] notification type: Power Management supported events: · Unknown (0x06) · Unknown (0x08) 20:38:22.210 SERIAL » 0x01070080130000006b (9 bytes) 20:38:22.211 DRIVER » [Node 019] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 20:38:22.211 CNTRLR « [Node 026] received supported notification events for Power Management: 6, 8 20:38:22.211 CNTRLR [Node 026] [+] [Notification] interviewComplete: true [Endpoint 0] [internal] 20:38:22.211 CNTRLR [Node 026] Interview stage completed: CommandClasses 20:38:22.212 CNTRLR [Node 026] Interview stage completed: OverwriteConfig 20:38:22.212 CNTRLR » [Node 026] requesting node neighbors... 20:38:22.214 SERIAL « [ACK] (0x06) 20:38:22.215 SERIAL « 0x012001803700ea8b0000000000000000000000000000000000000000000000000 (34 bytes) 008 20:38:22.215 SERIAL » [ACK] (0x06) 20:38:22.216 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 2, 3, 5, 6, 18, 20, 22, 23, 24, 25, 26, 28, 32 20:38:22.225 SERIAL » 0x010700801a00000062 (9 bytes) 20:38:22.225 DRIVER » [Node 026] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 20:38:22.225 CNTRLR « [Node 019] node neighbors received: 1, 2, 3, 5, 6, 18, 20, 22, 23, 24, 25, 2 6, 28, 32 20:38:22.226 CNTRLR [Node 019] Interview stage completed: Neighbors 20:38:22.226 CNTRLR [Node 019] Interview completed 20:38:22.226 CNTRLR [Node 019] The node is ready to be used 20:38:22.229 SERIAL « [ACK] (0x06) 20:38:22.230 SERIAL « 0x012001801700fe880000000000000000000000000000000000000000000000000 (34 bytes) 03f 20:38:22.230 SERIAL » [ACK] (0x06) 20:38:22.231 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 2, 3, 5, 18, 19, 20, 21, 22, 23, 24, 28, 32 20:38:22.234 SERIAL » 0x010a00131c0371010825a501 (12 bytes) 20:38:22.235 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 165 └─[NotificationCCEventSupportedGet] notification type: Power Management 20:38:22.235 CNTRLR « [Node 026] node neighbors received: 1, 2, 3, 5, 18, 19, 20, 21, 22, 23, 24, 28, 32 20:38:22.235 CNTRLR [Node 026] Interview stage completed: Neighbors 20:38:22.235 CNTRLR [Node 026] Interview completed 20:38:22.235 CNTRLR [Node 026] The node is ready to be used 20:38:22.240 SERIAL « [ACK] (0x06) 20:38:22.241 SERIAL « 0x0104011301e8 (6 bytes) 20:38:22.241 SERIAL » [ACK] (0x06) 20:38:22.242 DRIVER « [RES] [SendData] was sent: true 20:38:22.324 SERIAL « 0x01070013a500000648 (9 bytes) 20:38:22.324 SERIAL » [ACK] (0x06) 20:38:22.325 DRIVER « [REQ] [SendData] callback id: 165 transmit status: OK 20:38:22.376 SERIAL « 0x010c0004001c06710208024001d5 (14 bytes) 20:38:22.377 CNTRLR [Node 028] [~] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" => "unknown" 20:38:22.377 CNTRLR [Node 028] [+] [Notification] supportedNotificationEvents[8]: 6,8 [internal] 20:38:22.377 CNTRLR [Node 028] [Notification] Power Management[Over-current status]: [Endpoint 0] metadata updated 20:38:22.377 CNTRLR [Node 028] [Notification] Power Management[Over-load status]: met [Endpoint 0] adata updated 20:38:22.377 SERIAL » [ACK] (0x06) 20:38:22.378 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[NotificationCCEventSupportedReport] notification type: Power Management supported events: · Unknown (0x06) · Unknown (0x08) 20:38:22.378 CNTRLR « [Node 028] received supported notification events for Power Management: 6, 8 20:38:22.378 CNTRLR [Node 028] [+] [Notification] interviewComplete: true [Endpoint 0] [internal] 20:38:22.378 CNTRLR [Node 028] Interview stage completed: CommandClasses 20:38:22.378 CNTRLR [Node 028] Interview stage completed: OverwriteConfig 20:38:22.378 CNTRLR » [Node 028] requesting node neighbors... 20:38:22.380 SERIAL » 0x010700801c00000064 (9 bytes) 20:38:22.380 DRIVER » [Node 028] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 20:38:22.381 SERIAL « [ACK] (0x06) 20:38:22.383 SERIAL « 0x0120018037003e820000000000000000000000000000000000000000000000000 (34 bytes) 0d5 20:38:22.383 SERIAL » [ACK] (0x06) 20:38:22.383 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 2, 3, 5, 6, 18, 19, 20, 21, 22, 26, 32 20:38:22.384 CNTRLR « [Node 028] node neighbors received: 1, 2, 3, 5, 6, 18, 19, 20, 21, 22, 26, 3 2 20:38:22.385 CNTRLR [Node 028] Interview stage completed: Neighbors 20:38:22.385 CNTRLR [Node 028] Interview completed 20:38:22.385 CNTRLR [Node 028] The node is ready to be used 20:38:23.894 SERIAL « 0x010c0004001a06310504220809f8 (14 bytes) 20:38:23.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:38:23.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 155.2 => 205.7 [Endpoint 0] 20:38:23.896 SERIAL » [ACK] (0x06) 20:38:23.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 205.7 20:38:27.895 SERIAL « 0x010c0004001a06310504220945b5 (14 bytes) 20:38:27.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:38:27.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 205.7 => 237.3 [Endpoint 0] 20:38:27.896 SERIAL » [ACK] (0x06) 20:38:27.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 237.3 20:38:41.662 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:38:41.663 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:38:41.664 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:38:41.664 SERIAL » [ACK] (0x06) 20:38:41.665 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:39:07.618 SERIAL « 0x0110000400120a32022134000000010000d7 (18 bytes) 20:39:07.618 CNTRLR [Node 018] [~] [Meter] value[66049]: 0.1 => 0.1 [Endpoint 0] 20:39:07.619 CNTRLR [Node 018] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:39:07.620 SERIAL » [ACK] (0x06) 20:39:07.621 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0.1 time delta: 0 seconds 20:40:06.894 SERIAL « 0x010c0004001a063105042211f71f (14 bytes) 20:40:06.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:40:06.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 237.3 => 459.9 [Endpoint 0] 20:40:06.896 SERIAL » [ACK] (0x06) 20:40:06.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 459.9 20:40:07.894 SERIAL « 0x010c0004001a0631050422086d9c (14 bytes) 20:40:07.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:40:07.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 459.9 => 215.7 [Endpoint 0] 20:40:07.896 SERIAL » [ACK] (0x06) 20:40:07.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 215.7 20:40:17.983 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:40:17.984 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:40:17.985 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:40:17.985 SERIAL » [ACK] (0x06) 20:40:17.986 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:40:31.828 SERIAL « 0x010c0004001c06310504220211ec (14 bytes) 20:40:31.829 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:40:31.829 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 65.8 => 52.9 [Endpoint 0] 20:40:31.830 SERIAL » [ACK] (0x06) 20:40:31.831 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 52.9 20:40:32.446 SERIAL « 0x0109000400110380035a39 (11 bytes) 20:40:32.447 CNTRLR [Node 017] [~] [Battery] level: 90 => 90 [Endpoint 0] 20:40:32.448 CNTRLR [Node 017] [~] [Battery] isLow: false => false [Endpoint 0] 20:40:32.449 SERIAL » [ACK] (0x06) 20:40:32.450 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 90 is low: false 20:40:32.504 SERIAL « 0x010c000400110643030142076c88 (14 bytes) 20:40:32.505 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpoint[1]: 19 => 19 [Endpoint 0] 20:40:32.507 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 20:40:32.508 SERIAL » [ACK] (0x06) 20:40:32.509 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 20:40:32.559 SERIAL « 0x010a00040011044608007fd5 (12 bytes) 20:40:32.561 CNTRLR [Node 017] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 20:40:32.561 CNTRLR [Node 017] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 20:40:32.562 SERIAL » [ACK] (0x06) 20:40:32.563 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ClimateControlScheduleCCOverrideReport] override type: None override state: Unused 20:40:32.613 SERIAL « 0x01080004001102840763 (10 bytes) 20:40:32.614 SERIAL » [ACK] (0x06) 20:40:32.614 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 20:40:32.616 CNTRLR « [Node 017] received wakeup notification 20:40:32.617 CNTRLR [Node 017] The node is now awake. 20:40:32.625 SERIAL » 0x01040060118a (6 bytes) 20:40:32.626 DRIVER » [Node 017] [REQ] [RequestNodeInfo] payload: 0x11 20:40:32.628 SERIAL « [ACK] (0x06) 20:40:32.632 SERIAL « 0x01040160019b (6 bytes) 20:40:32.632 SERIAL » [ACK] (0x06) 20:40:32.633 DRIVER « [RES] [RequestNodeInfo] payload: 0x01 20:40:32.669 SERIAL « 0x01160049841110040804804681728f75438684ef46818f04 (24 bytes) 20:40:32.670 SERIAL » [ACK] (0x06) 20:40:32.671 DRIVER « [Node 017] [REQ] [ApplicationUpdateRequest] payload: 0x841110040804804681728f75438684ef46818f 20:40:32.677 SERIAL » 0x010900131102840525a6f4 (11 bytes) 20:40:32.678 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 166 └─[WakeUpCCIntervalGet] 20:40:32.678 CNTRLR « [Node 017] node info received supported CCs: · Battery · Climate Control Schedule · Clock · Manufacturer Specific · Multi Command · Protection · Thermostat Setpoint · Version · Wake Up controlled CCs: · Climate Control Schedule · Clock · Multi Command 20:40:32.685 SERIAL « [ACK] (0x06) 20:40:32.686 SERIAL « 0x0104011301e8 (6 bytes) 20:40:32.686 SERIAL » [ACK] (0x06) 20:40:32.687 DRIVER « [RES] [SendData] was sent: true 20:40:32.690 CNTRLR [Node 017] Interview stage completed: NodeInfo 20:40:32.693 CNTRLR [Node 017] ManufacturerSpecificCC: doing a complete interview... 20:40:32.693 CNTRLR » [Node 017] querying manufacturer information... 20:40:32.699 SERIAL « 0x01070013a60000024f (9 bytes) 20:40:32.699 SERIAL » [ACK] (0x06) 20:40:32.700 DRIVER « [REQ] [SendData] callback id: 166 transmit status: OK 20:40:32.709 SERIAL « 0x010c0004001106840600012c014e (14 bytes) 20:40:32.710 CNTRLR [Node 017] [+] [Wake Up] wakeUpInterval: 300 [Endpoint 0] 20:40:32.711 CNTRLR [Node 017] [+] [Wake Up] controllerNodeId: 1 [Endpoint 0] 20:40:32.712 SERIAL » [ACK] (0x06) 20:40:32.713 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 300 seconds controller node id: 1 20:40:32.718 SERIAL » 0x010900131102840525a7f5 (11 bytes) 20:40:32.718 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 167 └─[WakeUpCCIntervalGet] 20:40:32.720 SERIAL « [ACK] (0x06) 20:40:32.724 SERIAL « 0x0104011301e8 (6 bytes) 20:40:32.724 SERIAL » [ACK] (0x06) 20:40:32.724 DRIVER « [RES] [SendData] was sent: true 20:40:32.739 SERIAL « 0x01070013a70000024e (9 bytes) 20:40:32.740 SERIAL » [ACK] (0x06) 20:40:32.740 DRIVER « [REQ] [SendData] callback id: 167 transmit status: OK 20:40:32.749 SERIAL « 0x010c0004001106840600012c014e (14 bytes) 20:40:32.750 CNTRLR [Node 017] [~] [Wake Up] wakeUpInterval: 300 => 300 [Endpoint 0] 20:40:32.750 CNTRLR [Node 017] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 20:40:32.750 SERIAL » [ACK] (0x06) 20:40:32.751 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 300 seconds controller node id: 1 20:40:32.754 SERIAL » 0x010900131102720425a80d (11 bytes) 20:40:32.754 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 168 └─[ManufacturerSpecificCCGet] 20:40:32.755 SERIAL « [ACK] (0x06) 20:40:32.759 SERIAL « 0x0104011301e8 (6 bytes) 20:40:32.759 SERIAL » [ACK] (0x06) 20:40:32.759 DRIVER « [RES] [SendData] was sent: true 20:40:32.775 SERIAL « 0x01070013a800000241 (9 bytes) 20:40:32.775 SERIAL » [ACK] (0x06) 20:40:32.776 DRIVER « [REQ] [SendData] callback id: 168 transmit status: OK 20:40:32.812 SERIAL « 0x010e0004001108720500020005000498 (16 bytes) 20:40:32.813 CNTRLR [Node 017] [+] [Manufacturer Specific] manufacturerId: 2 [Endpoint 0] 20:40:32.814 CNTRLR [Node 017] [+] [Manufacturer Specific] productType: 5 [Endpoint 0] 20:40:32.814 CNTRLR [Node 017] [+] [Manufacturer Specific] productId: 4 [Endpoint 0] 20:40:32.815 SERIAL » [ACK] (0x06) 20:40:32.817 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ManufacturerSpecificCCReport] manufacturer id: 0x02 product type: 0x05 product id: 0x04 20:40:32.819 CNTRLR « [Node 017] received response for manufacturer information: manufacturer: Danfoss (0x02) product type: 0x05 product id: 0x04 20:40:32.820 CNTRLR [Node 017] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 20:40:32.820 CNTRLR [Node 017] VersionCC: doing a complete interview... 20:40:32.820 CNTRLR » [Node 017] querying node versions... 20:40:32.825 SERIAL » 0x010900131102861125a9ed (11 bytes) 20:40:32.825 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 169 └─[VersionCCGet] 20:40:32.827 SERIAL « [ACK] (0x06) 20:40:32.830 SERIAL « 0x0104011301e8 (6 bytes) 20:40:32.830 SERIAL » [ACK] (0x06) 20:40:32.831 DRIVER « [RES] [SendData] was sent: true 20:40:32.846 SERIAL « 0x01070013a900000240 (9 bytes) 20:40:32.847 SERIAL » [ACK] (0x06) 20:40:32.847 DRIVER « [REQ] [SendData] callback id: 169 transmit status: OK 20:40:32.856 SERIAL « 0x010d00040011078612060343010132 (15 bytes) 20:40:32.857 CNTRLR [Node 017] [+] [Version] libraryType: 6 [Endpoint 0] 20:40:32.858 CNTRLR [Node 017] [+] [Version] protocolVersion: "3.67" [Endpoint 0] 20:40:32.858 CNTRLR [Node 017] [+] [Version] firmwareVersions: 1.1 [Endpoint 0] 20:40:32.859 SERIAL » [ACK] (0x06) 20:40:32.860 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[VersionCCReport] library type: Routing Slave protocol version: 3.67 firmware versions: 1.1 20:40:32.862 CNTRLR « [Node 017] received response for node versions: library type: Routing Slave (0x06) protocol version: 3.67 firmware versions: 1.1 20:40:32.862 CNTRLR » [Node 017] querying CC versions... 20:40:32.862 CNTRLR » [Node 017] querying the CC version for Manufacturer Specific (0x72)... 20:40:32.866 SERIAL » 0x010a0013110386137225aa9c (12 bytes) 20:40:32.867 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 170 └─[VersionCCCommandClassGet] CC: Manufacturer Specific 20:40:32.871 SERIAL « [ACK] (0x06) 20:40:32.873 SERIAL « 0x0104011301e8 (6 bytes) 20:40:32.873 SERIAL » [ACK] (0x06) 20:40:32.873 DRIVER « [RES] [SendData] was sent: true 20:40:32.888 SERIAL « 0x01070013aa00000243 (9 bytes) 20:40:32.888 SERIAL » [ACK] (0x06) 20:40:32.889 DRIVER « [REQ] [SendData] callback id: 170 transmit status: OK 20:40:32.897 SERIAL « 0x010a00040011048614720105 (12 bytes) 20:40:32.898 SERIAL » [ACK] (0x06) 20:40:32.898 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 1 20:40:32.899 CNTRLR [Node 017] supports CC Manufacturer Specific (0x72) in version 1 20:40:32.899 CNTRLR [Node 017] skipping query for Multi Command (0x8f) because max implemented v ersion is 1 20:40:32.899 CNTRLR » [Node 017] querying the CC version for Thermostat Setpoint (0x43)... 20:40:32.903 SERIAL » 0x010a0013110386134325abac (12 bytes) 20:40:32.903 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 171 └─[VersionCCCommandClassGet] CC: Thermostat Setpoint 20:40:32.904 SERIAL « [ACK] (0x06) 20:40:32.908 SERIAL « 0x0104011301e8 (6 bytes) 20:40:32.908 SERIAL » [ACK] (0x06) 20:40:32.908 DRIVER « [RES] [SendData] was sent: true 20:40:32.924 SERIAL « 0x01070013ab00000242 (9 bytes) 20:40:32.924 SERIAL » [ACK] (0x06) 20:40:32.924 DRIVER « [REQ] [SendData] callback id: 171 transmit status: OK 20:40:32.933 SERIAL « 0x010a00040011048614430237 (12 bytes) 20:40:32.933 SERIAL » [ACK] (0x06) 20:40:32.934 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Thermostat Setpoint version: 2 20:40:32.935 CNTRLR [Node 017] supports CC Thermostat Setpoint (0x43) in version 2 20:40:32.935 CNTRLR » [Node 017] querying the CC version for Version (0x86)... 20:40:32.938 SERIAL » 0x010a0013110386138625ac6e (12 bytes) 20:40:32.939 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 172 └─[VersionCCCommandClassGet] CC: Version 20:40:32.940 SERIAL « [ACK] (0x06) 20:40:32.944 SERIAL « 0x0104011301e8 (6 bytes) 20:40:32.944 SERIAL » [ACK] (0x06) 20:40:32.945 DRIVER « [RES] [SendData] was sent: true 20:40:32.960 SERIAL « 0x01070013ac00000245 (9 bytes) 20:40:32.960 SERIAL » [ACK] (0x06) 20:40:32.961 DRIVER « [REQ] [SendData] callback id: 172 transmit status: OK 20:40:32.971 SERIAL « 0x010a000400110486148601f1 (12 bytes) 20:40:32.971 SERIAL » [ACK] (0x06) 20:40:32.972 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 1 20:40:32.973 CNTRLR [Node 017] supports CC Version (0x86) in version 1 20:40:32.973 CNTRLR » [Node 017] querying the CC version for Wake Up (0x84)... 20:40:32.977 SERIAL » 0x010a0013110386138425ad6d (12 bytes) 20:40:32.978 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 173 └─[VersionCCCommandClassGet] CC: Wake Up 20:40:32.984 SERIAL « [ACK] (0x06) 20:40:32.985 SERIAL « 0x0104011301e8 (6 bytes) 20:40:32.985 SERIAL » [ACK] (0x06) 20:40:32.986 DRIVER « [RES] [SendData] was sent: true 20:40:32.999 SERIAL « 0x01070013ad00000147 (9 bytes) 20:40:32.999 SERIAL » [ACK] (0x06) 20:40:33.000 DRIVER « [REQ] [SendData] callback id: 173 transmit status: OK 20:40:33.008 SERIAL « 0x010a000400110486148402f0 (12 bytes) 20:40:33.008 SERIAL » [ACK] (0x06) 20:40:33.009 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Wake Up version: 2 20:40:33.011 CNTRLR [Node 017] supports CC Wake Up (0x84) in version 2 20:40:33.011 CNTRLR » [Node 017] querying the CC version for Battery (0x80)... 20:40:33.015 SERIAL » 0x010a0013110386138025ae6a (12 bytes) 20:40:33.015 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 174 └─[VersionCCCommandClassGet] CC: Battery 20:40:33.016 SERIAL « [ACK] (0x06) 20:40:33.020 SERIAL « 0x0104011301e8 (6 bytes) 20:40:33.021 SERIAL » [ACK] (0x06) 20:40:33.021 DRIVER « [RES] [SendData] was sent: true 20:40:33.036 SERIAL « 0x01070013ae00000247 (9 bytes) 20:40:33.037 SERIAL » [ACK] (0x06) 20:40:33.037 DRIVER « [REQ] [SendData] callback id: 174 transmit status: OK 20:40:33.045 SERIAL « 0x010a000400110486148001f7 (12 bytes) 20:40:33.046 SERIAL » [ACK] (0x06) 20:40:33.046 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Battery version: 1 20:40:33.048 CNTRLR [Node 017] supports CC Battery (0x80) in version 1 20:40:33.048 CNTRLR [Node 017] skipping query for Climate Control Schedule (0x46) because max im plemented version is 1 20:40:33.048 CNTRLR [Node 017] skipping query for Clock (0x81) because max implemented version i s 1 20:40:33.048 CNTRLR » [Node 017] querying the CC version for Protection (0x75)... 20:40:33.051 SERIAL » 0x010a0013110386137525af9e (12 bytes) 20:40:33.052 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 175 └─[VersionCCCommandClassGet] CC: Protection 20:40:33.053 SERIAL « [ACK] (0x06) 20:40:33.057 SERIAL « 0x0104011301e8 (6 bytes) 20:40:33.057 SERIAL » [ACK] (0x06) 20:40:33.057 DRIVER « [RES] [SendData] was sent: true 20:40:33.073 SERIAL « 0x01070013af00000246 (9 bytes) 20:40:33.073 SERIAL » [ACK] (0x06) 20:40:33.074 DRIVER « [REQ] [SendData] callback id: 175 transmit status: OK 20:40:33.082 SERIAL « 0x010a00040011048614750201 (12 bytes) 20:40:33.083 SERIAL » [ACK] (0x06) 20:40:33.083 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Protection version: 2 20:40:33.085 CNTRLR [Node 017] supports CC Protection (0x75) in version 2 20:40:33.085 CNTRLR [Node 017] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 20:40:33.085 CNTRLR [Node 017] trying to load device config 20:40:33.093 CNTRLR [Node 017] device config loaded 20:40:33.095 CNTRLR [Node 017] WakeUpCC: doing a complete interview... 20:40:33.095 CNTRLR » [Node 017] retrieving wakeup capabilities from the device... 20:40:33.101 SERIAL » 0x010900131102840925b0ee (11 bytes) 20:40:33.102 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 176 └─[WakeUpCCIntervalCapabilitiesGet] 20:40:33.103 SERIAL « [ACK] (0x06) 20:40:33.107 SERIAL « 0x0104011301e8 (6 bytes) 20:40:33.108 SERIAL » [ACK] (0x06) 20:40:33.108 DRIVER « [RES] [SendData] was sent: true 20:40:33.123 SERIAL « 0x01070013b000000259 (9 bytes) 20:40:33.124 SERIAL » [ACK] (0x06) 20:40:33.124 DRIVER « [REQ] [SendData] callback id: 176 transmit status: OK 20:40:33.135 SERIAL « 0x0114000400110e840a00003c00070800012c00003c5c (22 bytes) 20:40:33.136 CNTRLR [Node 017] [Wake Up] wakeUpInterval: metadata updated [Endpoint 0] 20:40:33.137 SERIAL » [ACK] (0x06) 20:40:33.137 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalCapabilitiesReport] default interval: 300 seconds minimum interval: 60 seconds maximum interval: 1800 seconds interval steps: 60 seconds 20:40:33.139 CNTRLR « [Node 017] received wakeup capabilities: default wakeup interval: 300 seconds minimum wakeup interval: 60 seconds maximum wakeup interval: 1800 seconds wakeup interval steps: 60 seconds 20:40:33.139 CNTRLR » [Node 017] retrieving wakeup interval from the device... 20:40:33.143 SERIAL » 0x010900131102840525b1e3 (11 bytes) 20:40:33.143 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 177 └─[WakeUpCCIntervalGet] 20:40:33.144 SERIAL « [ACK] (0x06) 20:40:33.148 SERIAL « 0x0104011301e8 (6 bytes) 20:40:33.148 SERIAL » [ACK] (0x06) 20:40:33.149 DRIVER « [RES] [SendData] was sent: true 20:40:33.164 SERIAL « 0x01070013b100000258 (9 bytes) 20:40:33.164 SERIAL » [ACK] (0x06) 20:40:33.165 DRIVER « [REQ] [SendData] callback id: 177 transmit status: OK 20:40:33.174 SERIAL « 0x010c0004001106840600012c014e (14 bytes) 20:40:33.174 CNTRLR [Node 017] [~] [Wake Up] wakeUpInterval: 300 => 300 [Endpoint 0] 20:40:33.177 CNTRLR [Node 017] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 20:40:33.178 SERIAL » [ACK] (0x06) 20:40:33.179 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 300 seconds controller node id: 1 20:40:33.180 CNTRLR « [Node 017] received wakeup configuration: wakeup interval: 300 seconds controller node: 1 20:40:33.180 CNTRLR [Node 017] [+] [Wake Up] interviewComplete: true [Endpoint 0] [internal] 20:40:33.189 CNTRLR [Node 017] BatteryCC: doing a complete interview... 20:40:33.189 CNTRLR » [Node 017] querying battery status... 20:40:33.193 SERIAL » 0x010900131102800225b2e3 (11 bytes) 20:40:33.193 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 178 └─[BatteryCCGet] 20:40:33.194 SERIAL « [ACK] (0x06) 20:40:33.198 SERIAL « 0x0104011301e8 (6 bytes) 20:40:33.198 SERIAL » [ACK] (0x06) 20:40:33.199 DRIVER « [RES] [SendData] was sent: true 20:40:33.214 SERIAL « 0x01070013b20000025b (9 bytes) 20:40:33.215 SERIAL » [ACK] (0x06) 20:40:33.215 DRIVER « [REQ] [SendData] callback id: 178 transmit status: OK 20:40:33.223 SERIAL « 0x0109000400110380035a39 (11 bytes) 20:40:33.223 CNTRLR [Node 017] [~] [Battery] level: 90 => 90 [Endpoint 0] 20:40:33.224 CNTRLR [Node 017] [~] [Battery] isLow: false => false [Endpoint 0] 20:40:33.224 SERIAL » [ACK] (0x06) 20:40:33.226 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 90 is low: false 20:40:33.227 CNTRLR « [Node 017] received response for battery information: level: 90 20:40:33.227 CNTRLR [Node 017] [+] [Battery] interviewComplete: true [Endpoint 0] [internal] 20:40:33.228 CNTRLR [Node 017] ThermostatSetpointCC: doing a complete interview... 20:40:33.228 CNTRLR » [Node 017] retrieving supported setpoint types... 20:40:33.230 SERIAL » 0x010900131102430425b327 (11 bytes) 20:40:33.231 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 179 └─[ThermostatSetpointCCSupportedGet] 20:40:33.232 SERIAL « [ACK] (0x06) 20:40:33.236 SERIAL « 0x0104011301e8 (6 bytes) 20:40:33.236 SERIAL » [ACK] (0x06) 20:40:33.237 DRIVER « [RES] [SendData] was sent: true 20:40:33.252 SERIAL « 0x01070013b30000025a (9 bytes) 20:40:33.252 SERIAL » [ACK] (0x06) 20:40:33.253 DRIVER « [REQ] [SendData] callback id: 179 transmit status: OK 20:40:33.261 SERIAL « 0x01090004001103430502a4 (11 bytes) 20:40:33.262 CNTRLR [Node 017] [+] [Thermostat Setpoint] supportedSetpoint [Endpoint 0] [internal] Types: 1 20:40:33.262 SERIAL » [ACK] (0x06) 20:40:33.262 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCSupportedReport] supported setpoint types: · Heating 20:40:33.263 CNTRLR [Node 017] Thermostat Setpoint bitmap interpretation is unknown, assuming B fo r now 20:40:33.263 CNTRLR » [Node 017] querying current value of setpoint Heating... 20:40:33.266 SERIAL » 0x010a0013110343020125b425 (12 bytes) 20:40:33.266 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 180 └─[ThermostatSetpointCCGet] setpoint type: Heating 20:40:33.267 SERIAL « [ACK] (0x06) 20:40:33.272 SERIAL « 0x0104011301e8 (6 bytes) 20:40:33.272 SERIAL » [ACK] (0x06) 20:40:33.272 DRIVER « [RES] [SendData] was sent: true 20:40:33.288 SERIAL « 0x01070013b40000025d (9 bytes) 20:40:33.288 SERIAL » [ACK] (0x06) 20:40:33.288 DRIVER « [REQ] [SendData] callback id: 180 transmit status: OK 20:40:33.297 SERIAL « 0x010c000400110643030142076c88 (14 bytes) 20:40:33.298 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpoint[1]: 19 => 19 [Endpoint 0] 20:40:33.298 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 20:40:33.298 SERIAL » [ACK] (0x06) 20:40:33.299 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 20:40:33.300 CNTRLR « [Node 017] received current value of setpoint Heating: 19 °C 20:40:33.300 CNTRLR [Node 017] [~] [Thermostat Setpoint] supportedSetpoint [Endpoint 0] [internal] Types: 1 => 1 20:40:33.301 CNTRLR [Node 017] [+] [Thermostat Setpoint] setpointTypesInte [Endpoint 0] [internal] rpretation: "B" 20:40:33.301 CNTRLR [Node 017] [+] [Thermostat Setpoint] interviewComplete [Endpoint 0] [internal] : true 20:40:33.301 CNTRLR [Node 017] ClockCC: doing a complete interview... 20:40:33.301 CNTRLR » [Node 017] requesting current clock setting... 20:40:33.324 SERIAL » 0x010900131102810525b5e2 (11 bytes) 20:40:33.324 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 181 └─[ClockCCGet] 20:40:33.325 SERIAL « [ACK] (0x06) 20:40:33.329 SERIAL « 0x0104011301e8 (6 bytes) 20:40:33.330 SERIAL » [ACK] (0x06) 20:40:33.330 DRIVER « [RES] [SendData] was sent: true 20:40:33.345 SERIAL « 0x01070013b50000025c (9 bytes) 20:40:33.345 SERIAL » [ACK] (0x06) 20:40:33.345 DRIVER « [REQ] [SendData] callback id: 181 transmit status: OK 20:40:33.354 SERIAL « 0x010a000400110481068633d6 (12 bytes) 20:40:33.354 SERIAL » [ACK] (0x06) 20:40:33.355 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ClockCCReport] clock setting: Thursday, 06:51 20:40:33.356 CNTRLR « [Node 017] received current clock setting: Thursday, 06:51 20:40:33.356 CNTRLR [Node 017] [+] [Clock] interviewComplete: true [Endpoint 0] [internal] 20:40:33.358 CNTRLR [Node 017] ProtectionCC: doing a complete interview... 20:40:33.359 CNTRLR » [Node 017] querying protection capabilities... 20:40:33.360 SERIAL » 0x010900131102750425b614 (11 bytes) 20:40:33.360 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 182 └─[ProtectionCCSupportedGet] 20:40:33.361 SERIAL « [ACK] (0x06) 20:40:33.365 SERIAL « 0x0104011301e8 (6 bytes) 20:40:33.365 SERIAL » [ACK] (0x06) 20:40:33.365 DRIVER « [RES] [SendData] was sent: true 20:40:33.381 SERIAL « 0x01070013b60000025f (9 bytes) 20:40:33.381 SERIAL » [ACK] (0x06) 20:40:33.381 DRIVER « [REQ] [SendData] callback id: 182 transmit status: OK 20:40:33.391 SERIAL « 0x010d00040011077505000500000095 (15 bytes) 20:40:33.391 CNTRLR [Node 017] [+] [Protection] supportsExclusiveControl: [Endpoint 0] [internal] false 20:40:33.392 CNTRLR [Node 017] [+] [Protection] supportsTimeout: false [Endpoint 0] [internal] 20:40:33.392 CNTRLR [Node 017] [+] [Protection] supportedLocalStates: 0,2 [Endpoint 0] [internal] 20:40:33.392 CNTRLR [Node 017] [+] [Protection] supportedRFStates: [Endpoint 0] [internal] 20:40:33.392 CNTRLR [Node 017] [Protection] local: metadata updated [Endpoint 0] 20:40:33.392 CNTRLR [Node 017] [Protection] rf: metadata updated [Endpoint 0] 20:40:33.392 SERIAL » [ACK] (0x06) 20:40:33.393 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ProtectionCCSupportedReport] supports exclusive control: false supports timeout: false local protection states: · Unprotected · NoOperationPossible RF protection states: 20:40:33.393 CNTRLR « [Node 017] received protection capabilities: exclusive control: false timeout: false local protection states: · Unprotected · NoOperationPossible RF protection states: 20:40:33.394 CNTRLR » [Node 017] querying protection status... 20:40:33.396 SERIAL » 0x010900131102750225b713 (11 bytes) 20:40:33.396 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 183 └─[ProtectionCCGet] 20:40:33.397 SERIAL « [ACK] (0x06) 20:40:33.401 SERIAL « 0x0104011301e8 (6 bytes) 20:40:33.401 SERIAL » [ACK] (0x06) 20:40:33.401 DRIVER « [RES] [SendData] was sent: true 20:40:33.417 SERIAL « 0x01070013b70000025e (9 bytes) 20:40:33.417 SERIAL » [ACK] (0x06) 20:40:33.418 DRIVER « [REQ] [SendData] callback id: 183 transmit status: OK 20:40:33.426 SERIAL « 0x010a00040011047503000092 (12 bytes) 20:40:33.427 CNTRLR [Node 017] [+] [Protection] local: 0 [Endpoint 0] 20:40:33.427 CNTRLR [Node 017] [+] [Protection] rf: 0 [Endpoint 0] 20:40:33.428 SERIAL » [ACK] (0x06) 20:40:33.428 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 20:40:33.429 CNTRLR « [Node 017] received protection status: local: Unprotected rf Unprotected 20:40:33.429 CNTRLR [Node 017] [+] [Protection] interviewComplete: true [Endpoint 0] [internal] 20:40:33.429 CNTRLR [Node 017] Interview stage completed: CommandClasses 20:40:33.430 CNTRLR [Node 017] Interview stage completed: OverwriteConfig 20:40:33.430 CNTRLR » [Node 017] requesting node neighbors... 20:40:33.432 SERIAL » 0x010700801100000069 (9 bytes) 20:40:33.432 DRIVER » [Node 017] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 20:40:33.433 SERIAL « [ACK] (0x06) 20:40:33.435 SERIAL « 0x01200180370000000000000000000000000000000000000000000000000000000 (34 bytes) 069 20:40:33.435 SERIAL » [ACK] (0x06) 20:40:33.436 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 2, 3, 5, 6 20:40:33.438 CNTRLR « [Node 017] node neighbors received: 1, 2, 3, 5, 6 20:40:33.438 CNTRLR [Node 017] Interview stage completed: Neighbors 20:40:33.438 CNTRLR [Node 017] Interview completed 20:40:33.438 CNTRLR [Node 017] The node is ready to be used 20:40:34.441 CNTRLR » [Node 017] Sending node back to sleep... 20:40:34.444 SERIAL » 0x010900131102840825b8e7 (11 bytes) 20:40:34.444 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 184 └─[WakeUpCCNoMoreInformation] 20:40:34.445 SERIAL « [ACK] (0x06) 20:40:34.449 SERIAL « 0x0104011301e8 (6 bytes) 20:40:34.449 SERIAL » [ACK] (0x06) 20:40:34.450 DRIVER « [RES] [SendData] was sent: true 20:40:34.465 SERIAL « 0x01070013b800000251 (9 bytes) 20:40:34.465 SERIAL » [ACK] (0x06) 20:40:34.466 DRIVER « [REQ] [SendData] callback id: 184 transmit status: OK 20:40:34.468 CNTRLR [Node 017] The node is now asleep. 20:40:34.469 CNTRLR [Node 017] Node asleep 20:40:35.828 SERIAL « 0x010c0004001c0631050422028b76 (14 bytes) 20:40:35.829 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:40:35.830 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 52.9 => 65.1 [Endpoint 0] 20:40:35.830 SERIAL » [ACK] (0x06) 20:40:35.831 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 65.1 20:40:55.828 SERIAL « 0x010c0004001c0631050422035ea2 (14 bytes) 20:40:55.829 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:40:55.829 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 65.1 => 86.2 [Endpoint 0] 20:40:55.830 SERIAL » [ACK] (0x06) 20:40:55.830 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 86.2 20:41:02.827 SERIAL « 0x010c0004001c0631050422063dc4 (14 bytes) 20:41:02.828 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:41:02.829 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 86.2 => 159.7 [Endpoint 0] 20:41:02.829 SERIAL » [ACK] (0x06) 20:41:02.830 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 159.7 20:41:03.828 SERIAL « 0x010c0004001c0631050422049e65 (14 bytes) 20:41:03.828 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:41:03.829 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 159.7 => 118.2 [Endpoint 0] 20:41:03.829 SERIAL » [ACK] (0x06) 20:41:03.830 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 118.2 20:41:04.828 SERIAL « 0x010c0004001c06310504220319e5 (14 bytes) 20:41:04.828 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:41:04.829 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 118.2 => 79.3 [Endpoint 0] 20:41:04.830 SERIAL » [ACK] (0x06) 20:41:04.830 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 79.3 20:41:05.828 SERIAL « 0x010c0004001c0631050422045da6 (14 bytes) 20:41:05.829 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:41:05.829 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 79.3 => 111.7 [Endpoint 0] 20:41:05.830 SERIAL » [ACK] (0x06) 20:41:05.831 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 111.7 20:41:08.828 SERIAL « 0x010c0004001c0631050422036498 (14 bytes) 20:41:08.828 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:41:08.829 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 111.7 => 86.8 [Endpoint 0] 20:41:08.830 SERIAL » [ACK] (0x06) 20:41:08.830 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 86.8 20:41:19.894 SERIAL « 0x010c0004001a063105042211c820 (14 bytes) 20:41:19.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:41:19.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 215.7 => 455.2 [Endpoint 0] 20:41:19.896 SERIAL » [ACK] (0x06) 20:41:19.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 455.2 20:41:20.894 SERIAL « 0x010c0004001a063105042209ec1c (14 bytes) 20:41:20.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:41:20.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 455.2 => 254 [Endpoint 0] 20:41:20.896 SERIAL » [ACK] (0x06) 20:41:20.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 254 20:41:33.827 SERIAL « 0x010c0004001c063105042202cc31 (14 bytes) 20:41:33.828 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:41:33.829 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 86.8 => 71.6 [Endpoint 0] 20:41:33.829 SERIAL » [ACK] (0x06) 20:41:33.830 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 71.6 20:41:37.827 SERIAL « 0x010c0004001c0631050422024bb6 (14 bytes) 20:41:37.828 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:41:37.829 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 71.6 => 58.7 [Endpoint 0] 20:41:37.829 SERIAL » [ACK] (0x06) 20:41:37.830 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 58.7 20:41:54.305 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:41:54.306 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:41:54.307 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:41:54.307 SERIAL » [ACK] (0x06) 20:41:54.308 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:42:06.827 SERIAL « 0x010c0004001c063105042202aa57 (14 bytes) 20:42:06.828 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:42:06.829 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 58.7 => 68.2 [Endpoint 0] 20:42:06.829 SERIAL » [ACK] (0x06) 20:42:06.830 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 68.2 20:42:51.827 SERIAL « 0x010c0004001c06310504220241bc (14 bytes) 20:42:51.827 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:42:51.828 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 68.2 => 57.7 [Endpoint 0] 20:42:51.829 SERIAL » [ACK] (0x06) 20:42:51.829 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 57.7 20:42:53.826 SERIAL « 0x010c0004001c063105042202a954 (14 bytes) 20:42:53.827 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:42:53.828 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 57.7 => 68.1 [Endpoint 0] 20:42:53.828 SERIAL » [ACK] (0x06) 20:42:53.829 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 68.1 20:43:06.828 SERIAL « 0x010c0004001c06310504220235c8 (14 bytes) 20:43:06.829 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:43:06.830 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 68.1 => 56.5 [Endpoint 0] 20:43:06.830 SERIAL » [ACK] (0x06) 20:43:06.831 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 56.5 20:43:11.826 SERIAL « 0x010c0004001c0631050422029c61 (14 bytes) 20:43:11.827 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:43:11.828 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 56.5 => 66.8 [Endpoint 0] 20:43:11.828 SERIAL » [ACK] (0x06) 20:43:11.829 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 66.8 20:43:30.626 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:43:30.628 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:43:30.629 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:43:30.629 SERIAL » [ACK] (0x06) 20:43:30.630 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:43:33.648 SERIAL « 0x0110000400060a32022134000000000000c2 (18 bytes) 20:43:33.649 CNTRLR [Node 006] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:43:33.650 CNTRLR [Node 006] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:43:33.650 SERIAL » [ACK] (0x06) 20:43:33.651 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:44:00.439 SERIAL « 0x0110000400130a3202214400000425000086 (18 bytes) 20:44:00.440 CNTRLR [Node 019] [~] [Meter] value[65537]: 10.61 => 10.61 [Endpoint 0] 20:44:00.440 CNTRLR [Node 019] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 20:44:00.441 SERIAL » [ACK] (0x06) 20:44:00.442 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 10.61 time delta: 0 seconds 20:44:30.817 SERIAL « 0x0110000400120a32022134000000010000d7 (18 bytes) 20:44:30.818 CNTRLR [Node 018] [~] [Meter] value[66049]: 0.1 => 0.1 [Endpoint 0] 20:44:30.819 CNTRLR [Node 018] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:44:30.819 SERIAL » [ACK] (0x06) 20:44:30.820 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0.1 time delta: 0 seconds 20:44:31.825 SERIAL « 0x010c0004001c06310504220230cd (14 bytes) 20:44:31.826 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:44:31.827 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 66.8 => 56 [Endpoint 0] 20:44:31.827 SERIAL » [ACK] (0x06) 20:44:31.828 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 56 20:44:34.877 SERIAL « 0x010c00040010063105012200c036 (14 bytes) 20:44:34.878 CNTRLR [Node 016] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 20:44:34.879 CNTRLR [Node 016] [+] [Multilevel Sensor] Air temperature: 19.2 [Endpoint 0] 20:44:34.880 SERIAL » [ACK] (0x06) 20:44:34.880 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 19.2 20:44:35.363 SERIAL « 0x010b0004001005310505014297 (13 bytes) 20:44:35.365 CNTRLR [Node 016] [Multilevel Sensor] Humidity: metadata updated [Endpoint 0] 20:44:35.365 CNTRLR [Node 016] [+] [Multilevel Sensor] Humidity: 66 [Endpoint 0] 20:44:35.366 SERIAL » [ACK] (0x06) 20:44:35.366 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Humidity scale: Percentage value value: 66 20:44:37.177 SERIAL « 0x0109000400100380036406 (11 bytes) 20:44:37.178 CNTRLR [Node 016] [+] [Battery] level: 100 [Endpoint 0] 20:44:37.178 CNTRLR [Node 016] [+] [Battery] isLow: false [Endpoint 0] 20:44:37.179 SERIAL » [ACK] (0x06) 20:44:37.180 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 20:44:41.037 SERIAL « 0x010c00040010063105030a0000dc (14 bytes) 20:44:41.038 CNTRLR [Node 016] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 20:44:41.039 CNTRLR [Node 016] [+] [Multilevel Sensor] Illuminance: 0 [Endpoint 0] 20:44:41.039 SERIAL » [ACK] (0x06) 20:44:41.040 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 0 20:44:41.137 SERIAL « 0x010b000400100531051b0100cb (13 bytes) 20:44:41.138 CNTRLR [Node 016] [Multilevel Sensor] Ultraviolet: metadata updated [Endpoint 0] 20:44:41.138 CNTRLR [Node 016] [+] [Multilevel Sensor] Ultraviolet: 0 [Endpoint 0] 20:44:41.139 SERIAL » [ACK] (0x06) 20:44:41.140 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Ultraviolet scale: UV index value: 0 20:44:41.157 SERIAL « 0x01080004001002840762 (10 bytes) 20:44:41.157 SERIAL » [ACK] (0x06) 20:44:41.157 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 20:44:41.158 CNTRLR « [Node 016] received wakeup notification 20:44:41.158 CNTRLR [Node 016] The node is now awake. 20:44:41.161 SERIAL » 0x01040060108b (6 bytes) 20:44:41.162 DRIVER » [Node 016] [REQ] [RequestNodeInfo] payload: 0x10 20:44:41.163 SERIAL « [ACK] (0x06) 20:44:41.167 SERIAL « 0x01040160019b (6 bytes) 20:44:41.167 SERIAL » [ACK] (0x06) 20:44:41.167 DRIVER « [RES] [RequestNodeInfo] payload: 0x01 20:44:41.195 SERIAL « 0x011800498410120421015e86725985737184803031707a5aefc2 (26 bytes) 20:44:41.195 SERIAL » [ACK] (0x06) 20:44:41.196 DRIVER « [Node 016] [REQ] [ApplicationUpdateRequest] payload: 0x8410120421015e86725985737184803031707a5aef 20:44:41.198 CNTRLR « [Node 016] node info received supported CCs: · Z-Wave Plus Info · Version · Manufacturer Specific · Association Group Information · Association · Powerlevel · Notification · Wake Up · Battery · Binary Sensor · Multilevel Sensor · Configuration · Firmware Update Meta Data · Device Reset Locally controlled CCs: 20:44:41.208 CNTRLR [Node 016] Interview stage completed: NodeInfo 20:44:41.211 CNTRLR [Node 016] ManufacturerSpecificCC: doing a complete interview... 20:44:41.211 CNTRLR » [Node 016] querying manufacturer information... 20:44:41.216 SERIAL » 0x010900131002720425b91d (11 bytes) 20:44:41.217 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 185 └─[ManufacturerSpecificCCGet] 20:44:41.218 SERIAL « [ACK] (0x06) 20:44:41.222 SERIAL « 0x0104011301e8 (6 bytes) 20:44:41.222 SERIAL » [ACK] (0x06) 20:44:41.223 DRIVER « [RES] [SendData] was sent: true 20:44:41.237 SERIAL « 0x01070013b900000250 (9 bytes) 20:44:41.237 SERIAL » [ACK] (0x06) 20:44:41.238 DRIVER « [REQ] [SendData] callback id: 185 transmit status: OK 20:44:41.247 SERIAL « 0x010e000400100872050086000200647a (16 bytes) 20:44:41.248 CNTRLR [Node 016] [+] [Manufacturer Specific] manufacturerId: 134 [Endpoint 0] 20:44:41.249 CNTRLR [Node 016] [+] [Manufacturer Specific] productType: 2 [Endpoint 0] 20:44:41.249 CNTRLR [Node 016] [+] [Manufacturer Specific] productId: 100 [Endpoint 0] 20:44:41.250 SERIAL » [ACK] (0x06) 20:44:41.251 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ManufacturerSpecificCCReport] manufacturer id: 0x86 product type: 0x02 product id: 0x64 20:44:41.252 CNTRLR « [Node 016] received response for manufacturer information: manufacturer: AEON Labs (0x86) product type: 0x02 product id: 0x64 20:44:41.253 CNTRLR [Node 016] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 20:44:41.254 CNTRLR [Node 016] VersionCC: doing a complete interview... 20:44:41.255 CNTRLR » [Node 016] querying node versions... 20:44:41.259 SERIAL » 0x010900131002861125baff (11 bytes) 20:44:41.259 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 186 └─[VersionCCGet] 20:44:41.261 SERIAL « [ACK] (0x06) 20:44:41.264 SERIAL « 0x0104011301e8 (6 bytes) 20:44:41.264 SERIAL » [ACK] (0x06) 20:44:41.265 DRIVER « [RES] [SendData] was sent: true 20:44:41.279 SERIAL « 0x01070013ba00000253 (9 bytes) 20:44:41.279 SERIAL » [ACK] (0x06) 20:44:41.280 DRIVER « [REQ] [SendData] callback id: 186 transmit status: OK 20:44:41.290 SERIAL « 0x010f000400100986120304050108640016 (17 bytes) 20:44:41.290 CNTRLR [Node 016] [+] [Version] libraryType: 3 [Endpoint 0] 20:44:41.291 CNTRLR [Node 016] [+] [Version] protocolVersion: "4.5" [Endpoint 0] 20:44:41.291 CNTRLR [Node 016] [+] [Version] firmwareVersions: 1.8 [Endpoint 0] 20:44:41.291 SERIAL » [ACK] (0x06) 20:44:41.292 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[VersionCCReport] library type: Enhanced Slave protocol version: 4.5 firmware versions: 1.8 20:44:41.292 CNTRLR « [Node 016] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 4.5 firmware versions: 1.8 20:44:41.292 CNTRLR » [Node 016] querying CC versions... 20:44:41.293 CNTRLR » [Node 016] querying the CC version for Basic (0x20)... 20:44:41.295 SERIAL » 0x010a0013100386132025bbde (12 bytes) 20:44:41.295 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 187 └─[VersionCCCommandClassGet] CC: Basic 20:44:41.296 SERIAL « [ACK] (0x06) 20:44:41.300 SERIAL « 0x0104011301e8 (6 bytes) 20:44:41.300 SERIAL » [ACK] (0x06) 20:44:41.300 DRIVER « [RES] [SendData] was sent: true 20:44:41.315 SERIAL « 0x01070013bb00000252 (9 bytes) 20:44:41.316 SERIAL » [ACK] (0x06) 20:44:41.316 DRIVER « [REQ] [SendData] callback id: 187 transmit status: OK 20:44:41.325 SERIAL « 0x010a00040010048614200156 (12 bytes) 20:44:41.325 SERIAL » [ACK] (0x06) 20:44:41.326 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Basic version: 1 20:44:41.327 CNTRLR [Node 016] supports CC Basic (0x20) in version 1 20:44:41.328 CNTRLR » [Node 016] querying the CC version for Multilevel Sensor (0x31)... 20:44:41.332 SERIAL » 0x010a0013100386133125bcc8 (12 bytes) 20:44:41.334 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 188 └─[VersionCCCommandClassGet] CC: Multilevel Sensor 20:44:41.335 SERIAL « [ACK] (0x06) 20:44:41.339 SERIAL « 0x0104011301e8 (6 bytes) 20:44:41.339 SERIAL » [ACK] (0x06) 20:44:41.340 DRIVER « [RES] [SendData] was sent: true 20:44:41.354 SERIAL « 0x01070013bc00000255 (9 bytes) 20:44:41.354 SERIAL » [ACK] (0x06) 20:44:41.355 DRIVER « [REQ] [SendData] callback id: 188 transmit status: OK 20:44:41.364 SERIAL « 0x010a00040010048614310543 (12 bytes) 20:44:41.364 SERIAL » [ACK] (0x06) 20:44:41.364 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multilevel Sensor version: 5 20:44:41.365 CNTRLR [Node 016] supports CC Multilevel Sensor (0x31) in version 5 20:44:41.365 CNTRLR » [Node 016] querying the CC version for Wake Up (0x84)... 20:44:41.368 SERIAL » 0x010a0013100386138425bd7c (12 bytes) 20:44:41.368 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 189 └─[VersionCCCommandClassGet] CC: Wake Up 20:44:41.369 SERIAL « [ACK] (0x06) 20:44:41.373 SERIAL « 0x0104011301e8 (6 bytes) 20:44:41.373 SERIAL » [ACK] (0x06) 20:44:41.373 DRIVER « [RES] [SendData] was sent: true 20:44:41.388 SERIAL « 0x01070013bd00000157 (9 bytes) 20:44:41.388 SERIAL » [ACK] (0x06) 20:44:41.388 DRIVER « [REQ] [SendData] callback id: 189 transmit status: OK 20:44:41.398 SERIAL « 0x010a000400100486148402f1 (12 bytes) 20:44:41.398 SERIAL » [ACK] (0x06) 20:44:41.398 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Wake Up version: 2 20:44:41.399 CNTRLR [Node 016] supports CC Wake Up (0x84) in version 2 20:44:41.399 CNTRLR » [Node 016] querying the CC version for Z-Wave Plus Info (0x5e)... 20:44:41.402 SERIAL » 0x010a0013100386135e25bea5 (12 bytes) 20:44:41.403 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 190 └─[VersionCCCommandClassGet] CC: Z-Wave Plus Info 20:44:41.403 SERIAL « [ACK] (0x06) 20:44:41.407 SERIAL « 0x0104011301e8 (6 bytes) 20:44:41.408 SERIAL » [ACK] (0x06) 20:44:41.408 DRIVER « [RES] [SendData] was sent: true 20:44:41.423 SERIAL « 0x01070013be00000257 (9 bytes) 20:44:41.423 SERIAL » [ACK] (0x06) 20:44:41.423 DRIVER « [REQ] [SendData] callback id: 190 transmit status: OK 20:44:41.432 SERIAL « 0x010a000400100486145e022b (12 bytes) 20:44:41.433 SERIAL » [ACK] (0x06) 20:44:41.433 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Z-Wave Plus Info version: 2 20:44:41.434 CNTRLR [Node 016] supports CC Z-Wave Plus Info (0x5e) in version 2 20:44:41.434 CNTRLR » [Node 016] querying the CC version for Version (0x86)... 20:44:41.436 SERIAL » 0x010a0013100386138625bf7c (12 bytes) 20:44:41.436 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 191 └─[VersionCCCommandClassGet] CC: Version 20:44:41.437 SERIAL « [ACK] (0x06) 20:44:41.441 SERIAL « 0x0104011301e8 (6 bytes) 20:44:41.441 SERIAL » [ACK] (0x06) 20:44:41.441 DRIVER « [RES] [SendData] was sent: true 20:44:41.456 SERIAL « 0x01070013bf00000256 (9 bytes) 20:44:41.456 SERIAL » [ACK] (0x06) 20:44:41.456 DRIVER « [REQ] [SendData] callback id: 191 transmit status: OK 20:44:41.466 SERIAL « 0x010a000400100486148602f3 (12 bytes) 20:44:41.467 SERIAL » [ACK] (0x06) 20:44:41.467 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 2 20:44:41.469 CNTRLR [Node 016] supports CC Version (0x86) in version 2 20:44:41.469 CNTRLR » [Node 016] querying the CC version for Manufacturer Specific (0x72)... 20:44:41.473 SERIAL » 0x010a0013100386137225c0f7 (12 bytes) 20:44:41.473 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 192 └─[VersionCCCommandClassGet] CC: Manufacturer Specific 20:44:41.474 SERIAL « [ACK] (0x06) 20:44:41.478 SERIAL « 0x0104011301e8 (6 bytes) 20:44:41.479 SERIAL » [ACK] (0x06) 20:44:41.479 DRIVER « [RES] [SendData] was sent: true 20:44:41.493 SERIAL « 0x01070013c000000229 (9 bytes) 20:44:41.494 SERIAL » [ACK] (0x06) 20:44:41.494 DRIVER « [REQ] [SendData] callback id: 192 transmit status: OK 20:44:41.503 SERIAL « 0x010a00040010048614720207 (12 bytes) 20:44:41.504 SERIAL » [ACK] (0x06) 20:44:41.504 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 2 20:44:41.505 CNTRLR [Node 016] supports CC Manufacturer Specific (0x72) in version 2 20:44:41.506 CNTRLR » [Node 016] querying the CC version for Association Group Information (0x59). .. 20:44:41.509 SERIAL » 0x010a0013100386135925c1dd (12 bytes) 20:44:41.509 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 193 └─[VersionCCCommandClassGet] CC: Association Group Information 20:44:41.510 SERIAL « [ACK] (0x06) 20:44:41.515 SERIAL « 0x0104011301e8 (6 bytes) 20:44:41.515 SERIAL » [ACK] (0x06) 20:44:41.516 DRIVER « [RES] [SendData] was sent: true 20:44:41.530 SERIAL « 0x01070013c100000228 (9 bytes) 20:44:41.530 SERIAL » [ACK] (0x06) 20:44:41.531 DRIVER « [REQ] [SendData] callback id: 193 transmit status: OK 20:44:41.539 SERIAL « 0x010a0004001004861459012f (12 bytes) 20:44:41.540 SERIAL » [ACK] (0x06) 20:44:41.540 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association Group Information version: 1 20:44:41.542 CNTRLR [Node 016] supports CC Association Group Information (0x59) in version 1 20:44:41.542 CNTRLR » [Node 016] querying the CC version for Association (0x85)... 20:44:41.546 SERIAL » 0x010a0013100386138525c202 (12 bytes) 20:44:41.546 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 194 └─[VersionCCCommandClassGet] CC: Association 20:44:41.547 SERIAL « [ACK] (0x06) 20:44:41.551 SERIAL « 0x0104011301e8 (6 bytes) 20:44:41.552 SERIAL » [ACK] (0x06) 20:44:41.552 DRIVER « [RES] [SendData] was sent: true 20:44:41.566 SERIAL « 0x01070013c20000022b (9 bytes) 20:44:41.567 SERIAL » [ACK] (0x06) 20:44:41.567 DRIVER « [REQ] [SendData] callback id: 194 transmit status: OK 20:44:41.576 SERIAL « 0x010a000400100486148502f0 (12 bytes) 20:44:41.577 SERIAL » [ACK] (0x06) 20:44:41.578 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association version: 2 20:44:41.579 CNTRLR [Node 016] supports CC Association (0x85) in version 2 20:44:41.579 CNTRLR [Node 016] skipping query for Powerlevel (0x73) because max implemented vers ion is 0 20:44:41.579 CNTRLR » [Node 016] querying the CC version for Notification (0x71)... 20:44:41.582 SERIAL » 0x010a0013100386137125c3f7 (12 bytes) 20:44:41.583 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 195 └─[VersionCCCommandClassGet] CC: Notification 20:44:41.584 SERIAL « [ACK] (0x06) 20:44:41.588 SERIAL « 0x0104011301e8 (6 bytes) 20:44:41.588 SERIAL » [ACK] (0x06) 20:44:41.589 DRIVER « [RES] [SendData] was sent: true 20:44:41.607 SERIAL « 0x01070013c30000022a (9 bytes) 20:44:41.607 SERIAL » [ACK] (0x06) 20:44:41.608 DRIVER « [REQ] [SendData] callback id: 195 transmit status: OK 20:44:41.612 SERIAL « 0x010a00040010048614710305 (12 bytes) 20:44:41.613 SERIAL » [ACK] (0x06) 20:44:41.613 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Notification version: 3 20:44:41.615 CNTRLR [Node 016] supports CC Notification (0x71) in version 3 20:44:41.615 CNTRLR » [Node 016] querying the CC version for Battery (0x80)... 20:44:41.620 SERIAL » 0x010a0013100386138025c401 (12 bytes) 20:44:41.621 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 196 └─[VersionCCCommandClassGet] CC: Battery 20:44:41.622 SERIAL « [ACK] (0x06) 20:44:41.626 SERIAL « 0x0104011301e8 (6 bytes) 20:44:41.626 SERIAL » [ACK] (0x06) 20:44:41.626 DRIVER « [RES] [SendData] was sent: true 20:44:41.641 SERIAL « 0x01070013c40000022d (9 bytes) 20:44:41.641 SERIAL » [ACK] (0x06) 20:44:41.641 DRIVER « [REQ] [SendData] callback id: 196 transmit status: OK 20:44:41.651 SERIAL « 0x010a000400100486148001f6 (12 bytes) 20:44:41.651 SERIAL » [ACK] (0x06) 20:44:41.651 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Battery version: 1 20:44:41.652 CNTRLR [Node 016] supports CC Battery (0x80) in version 1 20:44:41.652 CNTRLR » [Node 016] querying the CC version for Binary Sensor (0x30)... 20:44:41.654 SERIAL » 0x010a0013100386133025c5b0 (12 bytes) 20:44:41.654 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 197 └─[VersionCCCommandClassGet] CC: Binary Sensor 20:44:41.655 SERIAL « [ACK] (0x06) 20:44:41.659 SERIAL « 0x0104011301e8 (6 bytes) 20:44:41.659 SERIAL » [ACK] (0x06) 20:44:41.660 DRIVER « [RES] [SendData] was sent: true 20:44:41.674 SERIAL « 0x01070013c50000022c (9 bytes) 20:44:41.674 SERIAL » [ACK] (0x06) 20:44:41.675 DRIVER « [REQ] [SendData] callback id: 197 transmit status: OK 20:44:41.684 SERIAL « 0x010a00040010048614300146 (12 bytes) 20:44:41.684 SERIAL » [ACK] (0x06) 20:44:41.685 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Binary Sensor version: 1 20:44:41.686 CNTRLR [Node 016] supports CC Binary Sensor (0x30) in version 1 20:44:41.686 CNTRLR » [Node 016] querying the CC version for Configuration (0x70)... 20:44:41.689 SERIAL » 0x010a0013100386137025c6f3 (12 bytes) 20:44:41.689 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 198 └─[VersionCCCommandClassGet] CC: Configuration 20:44:41.690 SERIAL « [ACK] (0x06) 20:44:41.694 SERIAL « 0x0104011301e8 (6 bytes) 20:44:41.695 SERIAL » [ACK] (0x06) 20:44:41.695 DRIVER « [RES] [SendData] was sent: true 20:44:41.709 SERIAL « 0x01070013c60000022f (9 bytes) 20:44:41.709 SERIAL » [ACK] (0x06) 20:44:41.710 DRIVER « [REQ] [SendData] callback id: 198 transmit status: OK 20:44:41.719 SERIAL « 0x010a00040010048614700106 (12 bytes) 20:44:41.720 SERIAL » [ACK] (0x06) 20:44:41.720 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Configuration version: 1 20:44:41.721 CNTRLR [Node 016] supports CC Configuration (0x70) in version 1 20:44:41.721 CNTRLR » [Node 016] querying the CC version for Firmware Update Meta Data (0x7a)... 20:44:41.725 SERIAL » 0x010a0013100386137a25c7f8 (12 bytes) 20:44:41.725 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 199 └─[VersionCCCommandClassGet] CC: Firmware Update Meta Data 20:44:41.726 SERIAL « [ACK] (0x06) 20:44:41.730 SERIAL « 0x0104011301e8 (6 bytes) 20:44:41.731 SERIAL » [ACK] (0x06) 20:44:41.731 DRIVER « [RES] [SendData] was sent: true 20:44:41.745 SERIAL « 0x01070013c70000022e (9 bytes) 20:44:41.745 SERIAL » [ACK] (0x06) 20:44:41.746 DRIVER « [REQ] [SendData] callback id: 199 transmit status: OK 20:44:41.755 SERIAL « 0x010a000400100486147a020f (12 bytes) 20:44:41.756 SERIAL » [ACK] (0x06) 20:44:41.756 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Firmware Update Meta Data version: 2 20:44:41.757 CNTRLR [Node 016] supports CC Firmware Update Meta Data (0x7a) in version 2 20:44:41.758 CNTRLR [Node 016] skipping query for Device Reset Locally (0x5a) because max implem ented version is 1 20:44:41.758 CNTRLR [Node 016] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 20:44:41.758 CNTRLR [Node 016] trying to load device config 20:44:41.775 CNTRLR [Node 016] device config loaded 20:44:41.785 CNTRLR [Node 016] WakeUpCC: doing a complete interview... 20:44:41.786 CNTRLR » [Node 016] retrieving wakeup capabilities from the device... 20:44:41.788 SERIAL » 0x010900131002840925c897 (11 bytes) 20:44:41.788 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 200 └─[WakeUpCCIntervalCapabilitiesGet] 20:44:41.789 SERIAL « [ACK] (0x06) 20:44:41.793 SERIAL « 0x0104011301e8 (6 bytes) 20:44:41.793 SERIAL » [ACK] (0x06) 20:44:41.793 DRIVER « [RES] [SendData] was sent: true 20:44:41.808 SERIAL « 0x01070013c800000122 (9 bytes) 20:44:41.808 SERIAL » [ACK] (0x06) 20:44:41.808 DRIVER « [REQ] [SendData] callback id: 200 transmit status: OK 20:44:41.819 SERIAL « 0x0114000400100e840a0000f0000e10000e1000003cb3 (22 bytes) 20:44:41.819 CNTRLR [Node 016] [Wake Up] wakeUpInterval: metadata updated [Endpoint 0] 20:44:41.819 SERIAL » [ACK] (0x06) 20:44:41.820 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalCapabilitiesReport] default interval: 3600 seconds minimum interval: 240 seconds maximum interval: 3600 seconds interval steps: 60 seconds 20:44:41.820 CNTRLR « [Node 016] received wakeup capabilities: default wakeup interval: 3600 seconds minimum wakeup interval: 240 seconds maximum wakeup interval: 3600 seconds wakeup interval steps: 60 seconds 20:44:41.820 CNTRLR » [Node 016] retrieving wakeup interval from the device... 20:44:41.822 SERIAL » 0x010900131002840525c99a (11 bytes) 20:44:41.822 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 201 └─[WakeUpCCIntervalGet] 20:44:41.823 SERIAL « [ACK] (0x06) 20:44:41.827 SERIAL « 0x0104011301e8 (6 bytes) 20:44:41.827 SERIAL » [ACK] (0x06) 20:44:41.827 DRIVER « [RES] [SendData] was sent: true 20:44:41.842 SERIAL « 0x01070013c900000220 (9 bytes) 20:44:41.842 SERIAL » [ACK] (0x06) 20:44:41.842 DRIVER « [REQ] [SendData] callback id: 201 transmit status: OK 20:44:41.852 SERIAL « 0x010c00040010068406000e10017c (14 bytes) 20:44:41.853 CNTRLR [Node 016] [+] [Wake Up] wakeUpInterval: 3600 [Endpoint 0] 20:44:41.853 CNTRLR [Node 016] [+] [Wake Up] controllerNodeId: 1 [Endpoint 0] 20:44:41.853 SERIAL » [ACK] (0x06) 20:44:41.854 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 3600 seconds controller node id: 1 20:44:41.854 CNTRLR « [Node 016] received wakeup configuration: wakeup interval: 3600 seconds controller node: 1 20:44:41.854 CNTRLR [Node 016] [+] [Wake Up] interviewComplete: true [Endpoint 0] [internal] 20:44:41.855 CNTRLR [Node 016] ZWavePlusCC: doing a complete interview... 20:44:41.855 CNTRLR » [Node 016] querying Z-Wave+ information... 20:44:41.856 SERIAL » 0x0109001310025e0125ca47 (11 bytes) 20:44:41.856 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 202 └─[ZWavePlusCCGet] 20:44:41.857 SERIAL « [ACK] (0x06) 20:44:41.861 SERIAL « 0x0104011301e8 (6 bytes) 20:44:41.861 SERIAL » [ACK] (0x06) 20:44:41.861 DRIVER « [RES] [SendData] was sent: true 20:44:41.876 SERIAL « 0x01070013ca00000223 (9 bytes) 20:44:41.877 SERIAL » [ACK] (0x06) 20:44:41.877 DRIVER « [REQ] [SendData] callback id: 202 transmit status: OK 20:44:41.885 SERIAL « 0x010f00040010095e020106000c070c07b6 (17 bytes) 20:44:41.886 CNTRLR [Node 016] [+] [Z-Wave Plus Info] zwavePlusVersion: 1 [Endpoint 0] 20:44:41.886 CNTRLR [Node 016] [+] [Z-Wave Plus Info] nodeType: 0 [Endpoint 0] 20:44:41.886 CNTRLR [Node 016] [+] [Z-Wave Plus Info] roleType: 6 [Endpoint 0] 20:44:41.887 CNTRLR [Node 016] [+] [Z-Wave Plus Info] installerIcon: 3079 [Endpoint 0] 20:44:41.887 CNTRLR [Node 016] [+] [Z-Wave Plus Info] userIcon: 3079 [Endpoint 0] 20:44:41.887 SERIAL » [ACK] (0x06) 20:44:41.887 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ZWavePlusCCReport] version: 1 node type: Node role type: SleepingReportingSlave icon (mgmt.): 0x0c07 icon (user): 0x0c07 20:44:41.888 CNTRLR « [Node 016] received response for Z-Wave+ information: Z-Wave+ version: 1 role type: SleepingReportingSlave node type: Node installer icon: 0x0c07 user icon: 0x0c07 20:44:41.888 CNTRLR [Node 016] [+] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue 20:44:41.888 CNTRLR [Node 016] BatteryCC: doing a complete interview... 20:44:41.888 CNTRLR » [Node 016] querying battery status... 20:44:41.890 SERIAL » 0x010900131002800225cb9b (11 bytes) 20:44:41.890 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 203 └─[BatteryCCGet] 20:44:41.891 SERIAL « [ACK] (0x06) 20:44:41.895 SERIAL « 0x0104011301e8 (6 bytes) 20:44:41.895 SERIAL » [ACK] (0x06) 20:44:41.896 DRIVER « [RES] [SendData] was sent: true 20:44:41.911 SERIAL « 0x01070013cb00000222 (9 bytes) 20:44:41.911 SERIAL » [ACK] (0x06) 20:44:41.911 DRIVER « [REQ] [SendData] callback id: 203 transmit status: OK 20:44:43.298 SERIAL « 0x0109000400100380036406 (11 bytes) 20:44:43.299 CNTRLR [Node 016] [~] [Battery] level: 100 => 100 [Endpoint 0] 20:44:43.299 CNTRLR [Node 016] [~] [Battery] isLow: false => false [Endpoint 0] 20:44:43.300 SERIAL » [ACK] (0x06) 20:44:43.301 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 20:44:43.302 CNTRLR « [Node 016] received response for battery information: level: 100 20:44:43.303 CNTRLR [Node 016] [+] [Battery] interviewComplete: true [Endpoint 0] [internal] 20:44:43.307 CNTRLR [Node 016] BasicCC: doing a complete interview... 20:44:43.307 CNTRLR » [Node 016] querying Basic CC state... 20:44:43.311 SERIAL » 0x010900131002200225cc3c (11 bytes) 20:44:43.311 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 204 └─[BasicCCGet] 20:44:43.312 SERIAL « [ACK] (0x06) 20:44:43.316 SERIAL « 0x0104011301e8 (6 bytes) 20:44:43.316 SERIAL » [ACK] (0x06) 20:44:43.316 DRIVER « [RES] [SendData] was sent: true 20:44:43.331 SERIAL « 0x01070013cc00000225 (9 bytes) 20:44:43.331 SERIAL » [ACK] (0x06) 20:44:43.332 DRIVER « [REQ] [SendData] callback id: 204 transmit status: OK 20:44:43.341 SERIAL « 0x01090004001003200300c2 (11 bytes) 20:44:43.342 SERIAL » [ACK] (0x06) 20:44:43.343 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[BasicCCReport] current value: 0 20:44:43.344 CNTRLR « [Node 016] received Basic CC state: current value: 0 20:44:43.345 CNTRLR [Node 016] [+] [Basic] interviewComplete: true [Endpoint 0] [internal] 20:44:43.345 CNTRLR [Node 016] MultilevelSensorCC: doing a complete interview... 20:44:43.345 CNTRLR » [Node 016] retrieving supported sensor types... 20:44:43.350 SERIAL » 0x010900131002310125cd2f (11 bytes) 20:44:43.350 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 205 └─[MultilevelSensorCCGetSupportedSensor] 20:44:43.351 SERIAL « [ACK] (0x06) 20:44:43.355 SERIAL « 0x0104011301e8 (6 bytes) 20:44:43.356 SERIAL » [ACK] (0x06) 20:44:43.359 DRIVER « [RES] [SendData] was sent: true 20:44:43.370 SERIAL « 0x01070013cd00000224 (9 bytes) 20:44:43.370 SERIAL » [ACK] (0x06) 20:44:43.371 DRIVER « [REQ] [SendData] callback id: 205 transmit status: OK 20:44:43.380 SERIAL « 0x010c0004001006310215000004c3 (14 bytes) 20:44:43.381 CNTRLR [Node 016] [+] [Multilevel Sensor] supportedSensorType [Endpoint 0] [internal] s: 1,3,5,27 20:44:43.382 SERIAL » [ACK] (0x06) 20:44:43.383 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedSensorReport] supported sensor types: · Air temperature · Illuminance · Humidity · Ultraviolet 20:44:43.384 CNTRLR « [Node 016] received supported sensor types: · Air temperature · Illuminance · Humidity · Ultraviolet 20:44:43.385 CNTRLR » [Node 016] querying supported scales for Air temperature sensor 20:44:43.389 SERIAL » 0x010a0013100331030125ce2d (12 bytes) 20:44:43.390 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 206 └─[MultilevelSensorCCGetSupportedScale] sensor type: Air temperature 20:44:43.391 SERIAL « [ACK] (0x06) 20:44:43.395 SERIAL « 0x0104011301e8 (6 bytes) 20:44:43.396 SERIAL » [ACK] (0x06) 20:44:43.396 DRIVER « [RES] [SendData] was sent: true 20:44:43.410 SERIAL « 0x01070013ce00000227 (9 bytes) 20:44:43.411 SERIAL » [ACK] (0x06) 20:44:43.411 DRIVER « [REQ] [SendData] callback id: 206 transmit status: OK 20:44:43.447 SERIAL « 0x010c0004001006310215000004c3 (14 bytes) 20:44:43.448 CNTRLR [Node 016] [~] [Multilevel Sensor] supportedSensorType [Endpoint 0] [internal] s: 1,3,5,27 => 1,3,5,27 20:44:43.448 SERIAL » [ACK] (0x06) 20:44:43.449 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedSensorReport] supported sensor types: · Air temperature · Illuminance · Humidity · Ultraviolet 20:44:43.462 SERIAL « 0x010a000400100431060103d0 (12 bytes) 20:44:43.463 CNTRLR [Node 016] [+] [Multilevel Sensor] supportedScales[1]: [Endpoint 0] [internal] 0,1 20:44:43.463 SERIAL » [ACK] (0x06) 20:44:43.464 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedScaleReport] sensor type: Air temperature supported scales: · Celsius · Fahrenheit 20:44:43.465 CNTRLR « [Node 016] received supported scales: · Celsius · Fahrenheit 20:44:43.465 CNTRLR » [Node 016] querying Air temperature sensor reading... 20:44:43.469 SERIAL » 0x010b001310043104010025cf2d (13 bytes) 20:44:43.469 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 207 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 20:44:43.471 SERIAL « [ACK] (0x06) 20:44:43.475 SERIAL « 0x0104011301e8 (6 bytes) 20:44:43.475 SERIAL » [ACK] (0x06) 20:44:43.476 DRIVER « [RES] [SendData] was sent: true 20:44:43.490 SERIAL « 0x01070013cf00000226 (9 bytes) 20:44:43.490 SERIAL » [ACK] (0x06) 20:44:43.491 DRIVER « [REQ] [SendData] callback id: 207 transmit status: OK 20:44:43.958 SERIAL « 0x010c00040010063105012200bf49 (14 bytes) 20:44:43.959 CNTRLR [Node 016] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 20:44:43.960 CNTRLR [Node 016] [~] [Multilevel Sensor] Air temperature: 19.2 => 19.1 [Endpoint 0] 20:44:43.960 SERIAL » [ACK] (0x06) 20:44:43.961 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 19.1 20:44:43.963 CNTRLR « [Node 016] received current Air temperature sensor reading: 19.1 °C 20:44:43.963 CNTRLR » [Node 016] querying supported scales for Illuminance sensor 20:44:43.965 SERIAL » 0x010a0013100331030325d031 (12 bytes) 20:44:43.965 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 208 └─[MultilevelSensorCCGetSupportedScale] sensor type: Illuminance 20:44:43.966 SERIAL « [ACK] (0x06) 20:44:43.970 SERIAL « 0x0104011301e8 (6 bytes) 20:44:43.970 SERIAL » [ACK] (0x06) 20:44:43.970 DRIVER « [RES] [SendData] was sent: true 20:44:43.985 SERIAL « 0x01070013d000000239 (9 bytes) 20:44:43.985 SERIAL » [ACK] (0x06) 20:44:43.986 DRIVER « [REQ] [SendData] callback id: 208 transmit status: OK 20:44:43.995 SERIAL « 0x010a000400100431060302d3 (12 bytes) 20:44:43.996 CNTRLR [Node 016] [+] [Multilevel Sensor] supportedScales[3]: [Endpoint 0] [internal] 1 20:44:43.996 SERIAL » [ACK] (0x06) 20:44:43.996 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedScaleReport] sensor type: Illuminance supported scales: · Lux 20:44:43.998 CNTRLR « [Node 016] received supported scales: · Lux 20:44:43.998 CNTRLR » [Node 016] querying Illuminance sensor reading... 20:44:44.001 SERIAL » 0x010b001310043104030825d139 (13 bytes) 20:44:44.001 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 209 └─[MultilevelSensorCCGet] sensor type: Illuminance scale: Lux 20:44:44.002 SERIAL « [ACK] (0x06) 20:44:44.007 SERIAL « 0x0104011301e8 (6 bytes) 20:44:44.007 SERIAL » [ACK] (0x06) 20:44:44.007 DRIVER « [RES] [SendData] was sent: true 20:44:44.022 SERIAL « 0x01070013d100000238 (9 bytes) 20:44:44.022 SERIAL » [ACK] (0x06) 20:44:44.022 DRIVER « [REQ] [SendData] callback id: 209 transmit status: OK 20:44:45.625 CNTRLR [Node 016] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 20:44:46.129 SERIAL » 0x010b001310043104030825d139 (13 bytes) 20:44:46.129 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 209 └─[MultilevelSensorCCGet] sensor type: Illuminance scale: Lux 20:44:46.131 SERIAL « [ACK] (0x06) 20:44:46.135 SERIAL « 0x0104011301e8 (6 bytes) 20:44:46.135 SERIAL » [ACK] (0x06) 20:44:46.136 DRIVER « [RES] [SendData] was sent: true 20:44:46.150 SERIAL « 0x01070013d100000238 (9 bytes) 20:44:46.150 SERIAL » [ACK] (0x06) 20:44:46.151 DRIVER « [REQ] [SendData] callback id: 209 transmit status: OK 20:44:46.758 SERIAL « 0x010c00040010063105030a0000dc (14 bytes) 20:44:46.759 CNTRLR [Node 016] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 20:44:46.760 CNTRLR [Node 016] [~] [Multilevel Sensor] Illuminance: 0 => 0 [Endpoint 0] 20:44:46.760 SERIAL » [ACK] (0x06) 20:44:46.761 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 0 20:44:46.762 CNTRLR « [Node 016] received current Illuminance sensor reading: 0 Lux 20:44:46.762 CNTRLR » [Node 016] querying supported scales for Humidity sensor 20:44:46.765 SERIAL » 0x010a0013100331030525d235 (12 bytes) 20:44:46.765 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 210 └─[MultilevelSensorCCGetSupportedScale] sensor type: Humidity 20:44:46.766 SERIAL « [ACK] (0x06) 20:44:46.770 SERIAL « 0x0104011301e8 (6 bytes) 20:44:46.770 SERIAL » [ACK] (0x06) 20:44:46.770 DRIVER « [RES] [SendData] was sent: true 20:44:46.785 SERIAL « 0x01070013d20000023b (9 bytes) 20:44:46.785 SERIAL » [ACK] (0x06) 20:44:46.786 DRIVER « [REQ] [SendData] callback id: 210 transmit status: OK 20:44:46.795 SERIAL « 0x010a000400100431060501d6 (12 bytes) 20:44:46.796 CNTRLR [Node 016] [+] [Multilevel Sensor] supportedScales[5]: [Endpoint 0] [internal] 0 20:44:46.796 SERIAL » [ACK] (0x06) 20:44:46.796 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedScaleReport] sensor type: Humidity supported scales: · Percentage value 20:44:46.798 CNTRLR « [Node 016] received supported scales: · Percentage value 20:44:46.798 CNTRLR » [Node 016] querying Humidity sensor reading... 20:44:46.801 SERIAL » 0x010b001310043104050025d335 (13 bytes) 20:44:46.802 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 211 └─[MultilevelSensorCCGet] sensor type: Humidity scale: Percentage value 20:44:46.803 SERIAL « [ACK] (0x06) 20:44:46.807 SERIAL « 0x0104011301e8 (6 bytes) 20:44:46.807 SERIAL » [ACK] (0x06) 20:44:46.808 DRIVER « [RES] [SendData] was sent: true 20:44:46.822 SERIAL « 0x01070013d30000023a (9 bytes) 20:44:46.823 SERIAL » [ACK] (0x06) 20:44:46.823 DRIVER « [REQ] [SendData] callback id: 211 transmit status: OK 20:44:47.438 SERIAL « 0x010b0004001005310505014297 (13 bytes) 20:44:47.438 CNTRLR [Node 016] [Multilevel Sensor] Humidity: metadata updated [Endpoint 0] 20:44:47.438 CNTRLR [Node 016] [~] [Multilevel Sensor] Humidity: 66 => 66 [Endpoint 0] 20:44:47.439 SERIAL » [ACK] (0x06) 20:44:47.439 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Humidity scale: Percentage value value: 66 20:44:47.440 CNTRLR « [Node 016] received current Humidity sensor reading: 66 % 20:44:47.440 CNTRLR » [Node 016] querying supported scales for Ultraviolet sensor 20:44:47.441 SERIAL » 0x010a0013100331031b25d42d (12 bytes) 20:44:47.441 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 212 └─[MultilevelSensorCCGetSupportedScale] sensor type: Ultraviolet 20:44:47.442 SERIAL « [ACK] (0x06) 20:44:47.447 SERIAL « 0x0104011301e8 (6 bytes) 20:44:47.447 SERIAL » [ACK] (0x06) 20:44:47.447 DRIVER « [RES] [SendData] was sent: true 20:44:47.462 SERIAL « 0x01070013d40000023d (9 bytes) 20:44:47.462 SERIAL » [ACK] (0x06) 20:44:47.462 DRIVER « [REQ] [SendData] callback id: 212 transmit status: OK 20:44:47.471 SERIAL « 0x010a000400100431061b01c8 (12 bytes) 20:44:47.472 CNTRLR [Node 016] [+] [Multilevel Sensor] supportedScales[27] [Endpoint 0] [internal] : 0 20:44:47.472 SERIAL » [ACK] (0x06) 20:44:47.473 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedScaleReport] sensor type: Ultraviolet supported scales: · UV index 20:44:47.474 CNTRLR « [Node 016] received supported scales: · UV index 20:44:47.474 CNTRLR » [Node 016] querying Ultraviolet sensor reading... 20:44:47.478 SERIAL » 0x010b0013100431041b0025d52d (13 bytes) 20:44:47.478 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 213 └─[MultilevelSensorCCGet] sensor type: Ultraviolet scale: UV index 20:44:47.479 SERIAL « [ACK] (0x06) 20:44:47.483 SERIAL « 0x0104011301e8 (6 bytes) 20:44:47.484 SERIAL » [ACK] (0x06) 20:44:47.484 DRIVER « [RES] [SendData] was sent: true 20:44:47.499 SERIAL « 0x01070013d50000013f (9 bytes) 20:44:47.499 SERIAL » [ACK] (0x06) 20:44:47.499 DRIVER « [REQ] [SendData] callback id: 213 transmit status: OK 20:44:49.103 CNTRLR [Node 016] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 20:44:49.605 SERIAL » 0x010b0013100431041b0025d52d (13 bytes) 20:44:49.606 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 213 └─[MultilevelSensorCCGet] sensor type: Ultraviolet scale: UV index 20:44:49.607 SERIAL « [ACK] (0x06) 20:44:49.611 SERIAL « 0x0104011301e8 (6 bytes) 20:44:49.612 SERIAL » [ACK] (0x06) 20:44:49.612 DRIVER « [RES] [SendData] was sent: true 20:44:49.627 SERIAL « 0x01070013d50000023c (9 bytes) 20:44:49.627 SERIAL » [ACK] (0x06) 20:44:49.627 DRIVER « [REQ] [SendData] callback id: 213 transmit status: OK 20:44:50.338 SERIAL « 0x010b000400100531051b0100cb (13 bytes) 20:44:50.338 CNTRLR [Node 016] [Multilevel Sensor] Ultraviolet: metadata updated [Endpoint 0] 20:44:50.339 CNTRLR [Node 016] [~] [Multilevel Sensor] Ultraviolet: 0 => 0 [Endpoint 0] 20:44:50.339 SERIAL » [ACK] (0x06) 20:44:50.340 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Ultraviolet scale: UV index value: 0 20:44:50.340 CNTRLR « [Node 016] received current Ultraviolet sensor reading: 0 20:44:50.341 CNTRLR [Node 016] [+] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true 20:44:50.348 CNTRLR [Node 016] BinarySensorCC: doing a complete interview... 20:44:50.349 CNTRLR » [Node 016] querying current value... 20:44:50.355 SERIAL » 0x010900131002300225d636 (11 bytes) 20:44:50.356 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 214 └─[BinarySensorCCGet] type: Any 20:44:50.357 SERIAL « [ACK] (0x06) 20:44:50.361 SERIAL « 0x0104011301e8 (6 bytes) 20:44:50.361 SERIAL » [ACK] (0x06) 20:44:50.362 DRIVER « [RES] [SendData] was sent: true 20:44:50.376 SERIAL « 0x01070013d60000023f (9 bytes) 20:44:50.376 SERIAL » [ACK] (0x06) 20:44:50.377 DRIVER « [REQ] [SendData] callback id: 214 transmit status: OK 20:44:50.385 SERIAL « 0x01090004001003300300d2 (11 bytes) 20:44:50.387 CNTRLR [Node 016] [Binary Sensor] Any: metadata updated [Endpoint 0] 20:44:50.387 CNTRLR [Node 016] [+] [Binary Sensor] Any: false [Endpoint 0] 20:44:50.387 SERIAL » [ACK] (0x06) 20:44:50.388 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 20:44:50.389 CNTRLR « [Node 016] received current value: false 20:44:50.389 CNTRLR [Node 016] [+] [Binary Sensor] interviewComplete: true [Endpoint 0] [internal] 20:44:50.390 CNTRLR [Node 016] ConfigurationCC: Loading configuration parameters from device confi g 20:44:50.391 CNTRLR [Node 016] [+] [Configuration] isParamInformationFromConfig: false [internal] 20:44:50.392 CNTRLR [Node 016] [Configuration] 2: metadata updated 20:44:50.393 CNTRLR [Node 016] [Configuration] 3: metadata updated 20:44:50.394 CNTRLR [Node 016] [Configuration] 4: metadata updated 20:44:50.394 CNTRLR [Node 016] [Configuration] 5: metadata updated 20:44:50.395 CNTRLR [Node 016] [Configuration] 8: metadata updated 20:44:50.396 CNTRLR [Node 016] [Configuration] 9: metadata updated 20:44:50.396 CNTRLR [Node 016] [Configuration] 39: metadata updated 20:44:50.397 CNTRLR [Node 016] [Configuration] 40: metadata updated 20:44:50.397 CNTRLR [Node 016] [Configuration] 42: metadata updated 20:44:50.398 CNTRLR [Node 016] [Configuration] 43: metadata updated 20:44:50.399 CNTRLR [Node 016] [Configuration] 44: metadata updated 20:44:50.399 CNTRLR [Node 016] [Configuration] 45: metadata updated 20:44:50.400 CNTRLR [Node 016] [Configuration] 46: metadata updated 20:44:50.400 CNTRLR [Node 016] [Configuration] 81: metadata updated 20:44:50.401 CNTRLR [Node 016] [Configuration] 100: metadata updated 20:44:50.401 CNTRLR [Node 016] [Configuration] 110: metadata updated 20:44:50.402 CNTRLR [Node 016] [Configuration] 111: metadata updated 20:44:50.402 CNTRLR [Node 016] [Configuration] 112: metadata updated 20:44:50.403 CNTRLR [Node 016] [Configuration] 113: metadata updated 20:44:50.403 CNTRLR [Node 016] [Configuration] 201: metadata updated 20:44:50.404 CNTRLR [Node 016] [Configuration] 202: metadata updated 20:44:50.404 CNTRLR [Node 016] [Configuration] 203: metadata updated 20:44:50.405 CNTRLR [Node 016] [Configuration] 204: metadata updated 20:44:50.406 CNTRLR [Node 016] [Configuration] 252: metadata updated 20:44:50.406 CNTRLR [Node 016] [Configuration] 255: metadata updated 20:44:50.407 CNTRLR [Node 016] [Configuration] 101[1]: metadata updated 20:44:50.407 CNTRLR [Node 016] [Configuration] 101[16]: metadata updated 20:44:50.408 CNTRLR [Node 016] [Configuration] 101[32]: metadata updated 20:44:50.408 CNTRLR [Node 016] [Configuration] 101[64]: metadata updated 20:44:50.408 CNTRLR [Node 016] [Configuration] 101[128]: metadata updated 20:44:50.409 CNTRLR [Node 016] [Configuration] 102[1]: metadata updated 20:44:50.409 CNTRLR [Node 016] [Configuration] 102[16]: metadata updated 20:44:50.410 CNTRLR [Node 016] [Configuration] 102[32]: metadata updated 20:44:50.410 CNTRLR [Node 016] [Configuration] 102[64]: metadata updated 20:44:50.411 CNTRLR [Node 016] [Configuration] 102[128]: metadata updated 20:44:50.411 CNTRLR [Node 016] [Configuration] 103[1]: metadata updated 20:44:50.411 CNTRLR [Node 016] [Configuration] 103[16]: metadata updated 20:44:50.412 CNTRLR [Node 016] [Configuration] 103[32]: metadata updated 20:44:50.412 CNTRLR [Node 016] [Configuration] 103[64]: metadata updated 20:44:50.412 CNTRLR [Node 016] [Configuration] 103[128]: metadata updated 20:44:50.413 CNTRLR [Node 016] [Configuration] 41[15]: metadata updated 20:44:50.413 CNTRLR [Node 016] [Configuration] 41[16776960]: metadata updated 20:44:50.413 CNTRLR [Node 016] [Configuration] 201[255]: metadata updated 20:44:50.414 CNTRLR [Node 016] [Configuration] 201[65280]: metadata updated 20:44:50.414 CNTRLR [Node 016] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 20:44:50.415 CNTRLR » [Node 016] querying parameter #2 value... 20:44:50.418 SERIAL » 0x010a0013100370050225d770 (12 bytes) 20:44:50.418 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 215 └─[ConfigurationCCGet] parameter #: 2 20:44:50.421 SERIAL « [ACK] (0x06) 20:44:50.426 SERIAL « 0x0104011301e8 (6 bytes) 20:44:50.426 SERIAL » [ACK] (0x06) 20:44:50.427 DRIVER « [RES] [SendData] was sent: true 20:44:50.438 SERIAL « 0x01070013d70000013d (9 bytes) 20:44:50.438 SERIAL » [ACK] (0x06) 20:44:50.438 DRIVER « [REQ] [SendData] callback id: 215 transmit status: OK 20:44:50.449 SERIAL « 0x010b0004001005700602010090 (13 bytes) 20:44:50.450 CNTRLR [Node 016] [+] [Configuration] 2: 0 20:44:50.450 SERIAL » [ACK] (0x06) 20:44:50.451 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 0 20:44:50.451 CNTRLR « [Node 016] parameter #2 has value: 0 20:44:50.451 CNTRLR » [Node 016] querying parameter #3 value... 20:44:50.453 SERIAL » 0x010a0013100370050325d87e (12 bytes) 20:44:50.453 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 216 └─[ConfigurationCCGet] parameter #: 3 20:44:50.454 SERIAL « [ACK] (0x06) 20:44:50.458 SERIAL « 0x0104011301e8 (6 bytes) 20:44:50.458 SERIAL » [ACK] (0x06) 20:44:50.459 DRIVER « [RES] [SendData] was sent: true 20:44:50.473 SERIAL « 0x01070013d800000231 (9 bytes) 20:44:50.473 SERIAL » [ACK] (0x06) 20:44:50.473 DRIVER « [REQ] [SendData] callback id: 216 transmit status: OK 20:44:50.483 SERIAL « 0x010c000400100670060302001e88 (14 bytes) 20:44:50.485 CNTRLR [Node 016] [+] [Configuration] 3: 30 20:44:50.485 SERIAL » [ACK] (0x06) 20:44:50.485 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 2 value: 30 20:44:50.487 CNTRLR « [Node 016] parameter #3 has value: 30 20:44:50.487 CNTRLR » [Node 016] querying parameter #4 value... 20:44:50.488 SERIAL » 0x010a0013100370050425d978 (12 bytes) 20:44:50.489 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 217 └─[ConfigurationCCGet] parameter #: 4 20:44:50.489 SERIAL « [ACK] (0x06) 20:44:50.494 SERIAL « 0x0104011301e8 (6 bytes) 20:44:50.494 SERIAL » [ACK] (0x06) 20:44:50.494 DRIVER « [RES] [SendData] was sent: true 20:44:50.509 SERIAL « 0x01070013d900000230 (9 bytes) 20:44:50.509 SERIAL » [ACK] (0x06) 20:44:50.509 DRIVER « [REQ] [SendData] callback id: 217 transmit status: OK 20:44:50.519 SERIAL « 0x010b0004001005700604010395 (13 bytes) 20:44:50.524 CNTRLR [Node 016] [+] [Configuration] 4: 3 20:44:50.524 SERIAL » [ACK] (0x06) 20:44:50.525 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 1 value: 3 20:44:50.525 CNTRLR « [Node 016] parameter #4 has value: 3 20:44:50.526 CNTRLR » [Node 016] querying parameter #5 value... 20:44:50.528 SERIAL » 0x010a0013100370050525da7a (12 bytes) 20:44:50.528 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 218 └─[ConfigurationCCGet] parameter #: 5 20:44:50.530 SERIAL « [ACK] (0x06) 20:44:50.533 SERIAL « 0x0104011301e8 (6 bytes) 20:44:50.534 SERIAL » [ACK] (0x06) 20:44:50.534 DRIVER « [RES] [SendData] was sent: true 20:44:50.548 SERIAL « 0x01070013da00000130 (9 bytes) 20:44:50.549 SERIAL » [ACK] (0x06) 20:44:50.549 DRIVER « [REQ] [SendData] callback id: 218 transmit status: OK 20:44:50.558 SERIAL « 0x010b0004001005700605010295 (13 bytes) 20:44:50.560 CNTRLR [Node 016] [+] [Configuration] 5: 2 20:44:50.560 SERIAL » [ACK] (0x06) 20:44:50.560 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 1 value: 2 20:44:50.561 CNTRLR « [Node 016] parameter #5 has value: 2 20:44:50.561 CNTRLR » [Node 016] querying parameter #8 value... 20:44:50.562 SERIAL » 0x010a0013100370050825db76 (12 bytes) 20:44:50.562 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 219 └─[ConfigurationCCGet] parameter #: 8 20:44:50.564 SERIAL « [ACK] (0x06) 20:44:50.567 SERIAL « 0x0104011301e8 (6 bytes) 20:44:50.567 SERIAL » [ACK] (0x06) 20:44:50.568 DRIVER « [RES] [SendData] was sent: true 20:44:50.582 SERIAL « 0x01070013db00000232 (9 bytes) 20:44:50.583 SERIAL » [ACK] (0x06) 20:44:50.583 DRIVER « [REQ] [SendData] callback id: 219 transmit status: OK 20:44:50.593 SERIAL « 0x010b0004001005700608010f95 (13 bytes) 20:44:50.595 CNTRLR [Node 016] [+] [Configuration] 8: 15 20:44:50.596 SERIAL » [ACK] (0x06) 20:44:50.596 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 15 20:44:50.597 CNTRLR « [Node 016] parameter #8 has value: 15 20:44:50.598 CNTRLR » [Node 016] querying parameter #9 value... 20:44:50.601 SERIAL » 0x010a0013100370050925dc70 (12 bytes) 20:44:50.602 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 220 └─[ConfigurationCCGet] parameter #: 9 20:44:50.603 SERIAL « [ACK] (0x06) 20:44:50.607 SERIAL « 0x0104011301e8 (6 bytes) 20:44:50.607 SERIAL » [ACK] (0x06) 20:44:50.608 DRIVER « [RES] [SendData] was sent: true 20:44:50.622 SERIAL « 0x01070013dc00000235 (9 bytes) 20:44:50.622 SERIAL » [ACK] (0x06) 20:44:50.623 DRIVER « [REQ] [SendData] callback id: 220 transmit status: OK 20:44:50.632 SERIAL « 0x010c00040010067006090201009d (14 bytes) 20:44:50.635 CNTRLR [Node 016] [+] [Configuration] 9: 256 20:44:50.635 SERIAL » [ACK] (0x06) 20:44:50.636 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 2 value: 256 20:44:50.637 CNTRLR « [Node 016] parameter #9 has value: 256 20:44:50.638 CNTRLR » [Node 016] querying parameter #39 value... 20:44:50.641 SERIAL » 0x010a0013100370052725dd5f (12 bytes) 20:44:50.642 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 221 └─[ConfigurationCCGet] parameter #: 39 20:44:50.644 SERIAL « [ACK] (0x06) 20:44:50.648 SERIAL « 0x0104011301e8 (6 bytes) 20:44:50.648 SERIAL » [ACK] (0x06) 20:44:50.649 DRIVER « [RES] [SendData] was sent: true 20:44:50.662 SERIAL « 0x01070013dd00000234 (9 bytes) 20:44:50.663 SERIAL » [ACK] (0x06) 20:44:50.663 DRIVER « [REQ] [SendData] callback id: 221 transmit status: OK 20:44:50.672 SERIAL « 0x010b00040010057006270114a1 (13 bytes) 20:44:50.675 CNTRLR [Node 016] [+] [Configuration] 39: 20 20:44:50.675 SERIAL » [ACK] (0x06) 20:44:50.676 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 39 value size: 1 value: 20 20:44:50.677 CNTRLR « [Node 016] parameter #39 has value: 20 20:44:50.678 CNTRLR » [Node 016] querying parameter #40 value... 20:44:50.681 SERIAL » 0x010a0013100370052825de53 (12 bytes) 20:44:50.682 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 222 └─[ConfigurationCCGet] parameter #: 40 20:44:50.683 SERIAL « [ACK] (0x06) 20:44:50.687 SERIAL « 0x0104011301e8 (6 bytes) 20:44:50.688 SERIAL » [ACK] (0x06) 20:44:50.688 DRIVER « [RES] [SendData] was sent: true 20:44:50.702 SERIAL « 0x01070013de00000237 (9 bytes) 20:44:50.702 SERIAL » [ACK] (0x06) 20:44:50.703 DRIVER « [REQ] [SendData] callback id: 222 transmit status: OK 20:44:50.712 SERIAL « 0x010b00040010057006280100ba (13 bytes) 20:44:50.714 CNTRLR [Node 016] [+] [Configuration] 40: 0 20:44:50.715 SERIAL » [ACK] (0x06) 20:44:50.716 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 0 20:44:50.717 CNTRLR « [Node 016] parameter #40 has value: 0 20:44:50.717 CNTRLR » [Node 016] querying parameter #42 value... 20:44:50.721 SERIAL » 0x010a0013100370052a25df50 (12 bytes) 20:44:50.721 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 223 └─[ConfigurationCCGet] parameter #: 42 20:44:50.723 SERIAL « [ACK] (0x06) 20:44:50.727 SERIAL « 0x0104011301e8 (6 bytes) 20:44:50.727 SERIAL » [ACK] (0x06) 20:44:50.728 DRIVER « [RES] [SendData] was sent: true 20:44:50.741 SERIAL « 0x01070013df00000236 (9 bytes) 20:44:50.741 SERIAL » [ACK] (0x06) 20:44:50.742 DRIVER « [REQ] [SendData] callback id: 223 transmit status: OK 20:44:50.751 SERIAL « 0x010b000400100570062a010ab2 (13 bytes) 20:44:50.753 CNTRLR [Node 016] [+] [Configuration] 42: 10 20:44:50.754 SERIAL » [ACK] (0x06) 20:44:50.754 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 10 20:44:50.755 CNTRLR « [Node 016] parameter #42 has value: 10 20:44:50.755 CNTRLR » [Node 016] querying parameter #43 value... 20:44:50.757 SERIAL » 0x010a0013100370052b25e06e (12 bytes) 20:44:50.762 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 224 └─[ConfigurationCCGet] parameter #: 43 20:44:50.763 SERIAL « [ACK] (0x06) 20:44:50.767 SERIAL « 0x0104011301e8 (6 bytes) 20:44:50.767 SERIAL » [ACK] (0x06) 20:44:50.768 DRIVER « [RES] [SendData] was sent: true 20:44:50.782 SERIAL « 0x01070013e000000209 (9 bytes) 20:44:50.782 SERIAL » [ACK] (0x06) 20:44:50.782 DRIVER « [REQ] [SendData] callback id: 224 transmit status: OK 20:44:50.792 SERIAL « 0x010c000400100670062b020064da (14 bytes) 20:44:50.793 CNTRLR [Node 016] [+] [Configuration] 43: 100 20:44:50.794 SERIAL » [ACK] (0x06) 20:44:50.794 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 2 value: 100 20:44:50.795 CNTRLR « [Node 016] parameter #43 has value: 100 20:44:50.795 CNTRLR » [Node 016] querying parameter #44 value... 20:44:50.797 SERIAL » 0x010a0013100370052c25e168 (12 bytes) 20:44:50.797 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 225 └─[ConfigurationCCGet] parameter #: 44 20:44:50.798 SERIAL « [ACK] (0x06) 20:44:50.803 SERIAL « 0x0104011301e8 (6 bytes) 20:44:50.803 SERIAL » [ACK] (0x06) 20:44:50.804 DRIVER « [RES] [SendData] was sent: true 20:44:50.817 SERIAL « 0x01070013e100000208 (9 bytes) 20:44:50.817 SERIAL » [ACK] (0x06) 20:44:50.817 DRIVER « [REQ] [SendData] callback id: 225 transmit status: OK 20:44:50.827 SERIAL « 0x010b000400100570062c010ab4 (13 bytes) 20:44:50.828 CNTRLR [Node 016] [+] [Configuration] 44: 10 20:44:50.828 SERIAL » [ACK] (0x06) 20:44:50.829 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 44 value size: 1 value: 10 20:44:50.829 CNTRLR « [Node 016] parameter #44 has value: 10 20:44:50.829 CNTRLR » [Node 016] querying parameter #45 value... 20:44:50.831 SERIAL » 0x010a0013100370052d25e26a (12 bytes) 20:44:50.831 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 226 └─[ConfigurationCCGet] parameter #: 45 20:44:50.832 SERIAL « [ACK] (0x06) 20:44:50.836 SERIAL « 0x0104011301e8 (6 bytes) 20:44:50.836 SERIAL » [ACK] (0x06) 20:44:50.836 DRIVER « [RES] [SendData] was sent: true 20:44:50.851 SERIAL « 0x01070013e20000020b (9 bytes) 20:44:50.851 SERIAL » [ACK] (0x06) 20:44:50.851 DRIVER « [REQ] [SendData] callback id: 226 transmit status: OK 20:44:50.861 SERIAL « 0x010b000400100570062d0102bd (13 bytes) 20:44:50.862 CNTRLR [Node 016] [+] [Configuration] 45: 2 20:44:50.863 SERIAL » [ACK] (0x06) 20:44:50.864 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 45 value size: 1 value: 2 20:44:50.865 CNTRLR « [Node 016] parameter #45 has value: 2 20:44:50.865 CNTRLR » [Node 016] querying parameter #46 value... 20:44:50.868 SERIAL » 0x010a0013100370052e25e368 (12 bytes) 20:44:50.868 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 227 └─[ConfigurationCCGet] parameter #: 46 20:44:50.870 SERIAL « [ACK] (0x06) 20:44:50.873 SERIAL « 0x0104011301e8 (6 bytes) 20:44:50.873 SERIAL » [ACK] (0x06) 20:44:50.874 DRIVER « [RES] [SendData] was sent: true 20:44:50.888 SERIAL « 0x01070013e300000109 (9 bytes) 20:44:50.888 SERIAL » [ACK] (0x06) 20:44:50.889 DRIVER « [REQ] [SendData] callback id: 227 transmit status: OK 20:44:50.898 SERIAL « 0x010b000400100570062e0100bc (13 bytes) 20:44:50.900 CNTRLR [Node 016] [+] [Configuration] 46: 0 20:44:50.901 SERIAL » [ACK] (0x06) 20:44:50.901 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 46 value size: 1 value: 0 20:44:50.902 CNTRLR « [Node 016] parameter #46 has value: 0 20:44:50.902 CNTRLR » [Node 016] querying parameter #81 value... 20:44:50.906 SERIAL » 0x010a0013100370055125e410 (12 bytes) 20:44:50.906 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 228 └─[ConfigurationCCGet] parameter #: 81 20:44:50.908 SERIAL « [ACK] (0x06) 20:44:50.912 SERIAL « 0x0104011301e8 (6 bytes) 20:44:50.912 SERIAL » [ACK] (0x06) 20:44:50.912 DRIVER « [RES] [SendData] was sent: true 20:44:50.927 SERIAL « 0x01070013e40000020d (9 bytes) 20:44:50.927 SERIAL » [ACK] (0x06) 20:44:50.928 DRIVER « [REQ] [SendData] callback id: 228 transmit status: OK 20:44:50.937 SERIAL « 0x010b00040010057006510101c2 (13 bytes) 20:44:50.939 CNTRLR [Node 016] [+] [Configuration] 81: 1 20:44:50.940 SERIAL » [ACK] (0x06) 20:44:50.940 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 81 value size: 1 value: 1 20:44:50.942 CNTRLR « [Node 016] parameter #81 has value: 1 20:44:50.942 CNTRLR » [Node 016] querying parameter #111 value... 20:44:50.945 SERIAL » 0x010a0013100370056f25e52f (12 bytes) 20:44:50.945 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 229 └─[ConfigurationCCGet] parameter #: 111 20:44:50.947 SERIAL « [ACK] (0x06) 20:44:50.952 SERIAL « 0x0104011301e8 (6 bytes) 20:44:50.952 SERIAL » [ACK] (0x06) 20:44:50.952 DRIVER « [RES] [SendData] was sent: true 20:44:50.966 SERIAL « 0x01070013e50000020c (9 bytes) 20:44:50.967 SERIAL » [ACK] (0x06) 20:44:50.967 DRIVER « [REQ] [SendData] callback id: 229 transmit status: OK 20:44:50.976 SERIAL « 0x010e000400100870066f0400000e10ee (16 bytes) 20:44:50.979 CNTRLR [Node 016] [+] [Configuration] 111: 3600 20:44:50.979 SERIAL » [ACK] (0x06) 20:44:50.980 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 111 value size: 4 value: 3600 20:44:50.981 CNTRLR « [Node 016] parameter #111 has value: 3600 20:44:50.981 CNTRLR » [Node 016] querying parameter #112 value... 20:44:50.985 SERIAL » 0x010a0013100370057025e633 (12 bytes) 20:44:50.985 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 230 └─[ConfigurationCCGet] parameter #: 112 20:44:50.986 SERIAL « [ACK] (0x06) 20:44:50.990 SERIAL « 0x0104011301e8 (6 bytes) 20:44:50.991 SERIAL » [ACK] (0x06) 20:44:50.991 DRIVER « [RES] [SendData] was sent: true 20:44:51.005 SERIAL « 0x01070013e60000020f (9 bytes) 20:44:51.005 SERIAL » [ACK] (0x06) 20:44:51.006 DRIVER « [REQ] [SendData] callback id: 230 transmit status: OK 20:44:51.015 SERIAL « 0x010e00040010087006700400000e10f1 (16 bytes) 20:44:51.018 CNTRLR [Node 016] [+] [Configuration] 112: 3600 20:44:51.019 SERIAL » [ACK] (0x06) 20:44:51.019 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 112 value size: 4 value: 3600 20:44:51.020 CNTRLR « [Node 016] parameter #112 has value: 3600 20:44:51.020 CNTRLR » [Node 016] querying parameter #113 value... 20:44:51.024 SERIAL » 0x010a0013100370057125e733 (12 bytes) 20:44:51.024 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 231 └─[ConfigurationCCGet] parameter #: 113 20:44:51.026 SERIAL « [ACK] (0x06) 20:44:51.030 SERIAL « 0x0104011301e8 (6 bytes) 20:44:51.030 SERIAL » [ACK] (0x06) 20:44:51.031 DRIVER « [RES] [SendData] was sent: true 20:44:51.045 SERIAL « 0x01070013e70000020e (9 bytes) 20:44:51.045 SERIAL » [ACK] (0x06) 20:44:51.045 DRIVER « [REQ] [SendData] callback id: 231 transmit status: OK 20:44:51.055 SERIAL « 0x010e00040010087006710400000e10f0 (16 bytes) 20:44:51.057 CNTRLR [Node 016] [+] [Configuration] 113: 3600 20:44:51.058 SERIAL » [ACK] (0x06) 20:44:51.058 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 113 value size: 4 value: 3600 20:44:51.060 CNTRLR « [Node 016] parameter #113 has value: 3600 20:44:51.060 CNTRLR » [Node 016] querying parameter #201 value... 20:44:51.063 SERIAL » 0x010a001310037005c925e884 (12 bytes) 20:44:51.063 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 232 └─[ConfigurationCCGet] parameter #: 201 20:44:51.065 SERIAL « [ACK] (0x06) 20:44:51.069 SERIAL « 0x0104011301e8 (6 bytes) 20:44:51.069 SERIAL » [ACK] (0x06) 20:44:51.070 DRIVER « [RES] [SendData] was sent: true 20:44:51.084 SERIAL « 0x01070013e800000201 (9 bytes) 20:44:51.084 SERIAL » [ACK] (0x06) 20:44:51.085 DRIVER « [REQ] [SendData] callback id: 232 transmit status: OK 20:44:51.094 SERIAL « 0x010c00040010067006c90200015d (14 bytes) 20:44:51.097 CNTRLR [Node 016] [+] [Configuration] 201[255]: 1 20:44:51.098 CNTRLR [Node 016] [+] [Configuration] 201[65280]: 0 20:44:51.099 SERIAL » [ACK] (0x06) 20:44:51.099 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 201 value size: 2 value: 1 20:44:51.100 CNTRLR « [Node 016] parameter #201 has value: 1 20:44:51.101 CNTRLR » [Node 016] querying parameter #202 value... 20:44:51.104 SERIAL » 0x010a001310037005ca25e986 (12 bytes) 20:44:51.104 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 233 └─[ConfigurationCCGet] parameter #: 202 20:44:51.106 SERIAL « [ACK] (0x06) 20:44:51.111 SERIAL « 0x0104011301e8 (6 bytes) 20:44:51.111 SERIAL » [ACK] (0x06) 20:44:51.112 DRIVER « [RES] [SendData] was sent: true 20:44:51.124 SERIAL « 0x01070013e900000200 (9 bytes) 20:44:51.124 SERIAL » [ACK] (0x06) 20:44:51.125 DRIVER « [REQ] [SendData] callback id: 233 transmit status: OK 20:44:51.134 SERIAL « 0x010b00040010057006ca010058 (13 bytes) 20:44:51.136 CNTRLR [Node 016] [+] [Configuration] 202: 0 20:44:51.137 SERIAL » [ACK] (0x06) 20:44:51.137 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 202 value size: 1 value: 0 20:44:51.138 CNTRLR « [Node 016] parameter #202 has value: 0 20:44:51.138 CNTRLR » [Node 016] querying parameter #203 value... 20:44:51.140 SERIAL » 0x010a001310037005cb25ea84 (12 bytes) 20:44:51.141 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 234 └─[ConfigurationCCGet] parameter #: 203 20:44:51.142 SERIAL « [ACK] (0x06) 20:44:51.146 SERIAL « 0x0104011301e8 (6 bytes) 20:44:51.146 SERIAL » [ACK] (0x06) 20:44:51.147 DRIVER « [RES] [SendData] was sent: true 20:44:51.161 SERIAL « 0x01070013ea00000203 (9 bytes) 20:44:51.161 SERIAL » [ACK] (0x06) 20:44:51.162 DRIVER « [REQ] [SendData] callback id: 234 transmit status: OK 20:44:51.171 SERIAL « 0x010c00040010067006cb0200005e (14 bytes) 20:44:51.173 CNTRLR [Node 016] [+] [Configuration] 203: 0 20:44:51.174 SERIAL » [ACK] (0x06) 20:44:51.175 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 203 value size: 2 value: 0 20:44:51.176 CNTRLR « [Node 016] parameter #203 has value: 0 20:44:51.176 CNTRLR » [Node 016] querying parameter #204 value... 20:44:51.179 SERIAL » 0x010a001310037005cc25eb82 (12 bytes) 20:44:51.180 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 235 └─[ConfigurationCCGet] parameter #: 204 20:44:51.182 SERIAL « [ACK] (0x06) 20:44:51.186 SERIAL « 0x0104011301e8 (6 bytes) 20:44:51.186 SERIAL » [ACK] (0x06) 20:44:51.187 DRIVER « [RES] [SendData] was sent: true 20:44:51.200 SERIAL « 0x01070013eb00000202 (9 bytes) 20:44:51.201 SERIAL » [ACK] (0x06) 20:44:51.201 DRIVER « [REQ] [SendData] callback id: 235 transmit status: OK 20:44:51.210 SERIAL « 0x010b00040010057006cc01005e (13 bytes) 20:44:51.212 CNTRLR [Node 016] [+] [Configuration] 204: 0 20:44:51.213 SERIAL » [ACK] (0x06) 20:44:51.214 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 204 value size: 1 value: 0 20:44:51.216 CNTRLR « [Node 016] parameter #204 has value: 0 20:44:51.216 CNTRLR » [Node 016] querying parameter #252 value... 20:44:51.219 SERIAL » 0x010a001310037005fc25ecb5 (12 bytes) 20:44:51.220 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 236 └─[ConfigurationCCGet] parameter #: 252 20:44:51.221 SERIAL « [ACK] (0x06) 20:44:51.225 SERIAL « 0x0104011301e8 (6 bytes) 20:44:51.226 SERIAL » [ACK] (0x06) 20:44:51.226 DRIVER « [RES] [SendData] was sent: true 20:44:51.240 SERIAL « 0x01070013ec00000205 (9 bytes) 20:44:51.240 SERIAL » [ACK] (0x06) 20:44:51.241 DRIVER « [REQ] [SendData] callback id: 236 transmit status: OK 20:44:51.250 SERIAL « 0x010b00040010057006fc01006e (13 bytes) 20:44:51.253 CNTRLR [Node 016] [+] [Configuration] 252: 0 20:44:51.254 SERIAL » [ACK] (0x06) 20:44:51.254 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 252 value size: 1 value: 0 20:44:51.255 CNTRLR « [Node 016] parameter #252 has value: 0 20:44:51.256 CNTRLR » [Node 016] querying parameter #101 value... 20:44:51.259 SERIAL » 0x010a0013100370056525ed2d (12 bytes) 20:44:51.259 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 237 └─[ConfigurationCCGet] parameter #: 101 20:44:51.261 SERIAL « [ACK] (0x06) 20:44:51.265 SERIAL « 0x0104011301e8 (6 bytes) 20:44:51.265 SERIAL » [ACK] (0x06) 20:44:51.266 DRIVER « [RES] [SendData] was sent: true 20:44:51.279 SERIAL « 0x01070013ed00000204 (9 bytes) 20:44:51.280 SERIAL » [ACK] (0x06) 20:44:51.280 DRIVER « [REQ] [SendData] callback id: 237 transmit status: OK 20:44:51.290 SERIAL « 0x010e000400100870066504000000f10b (16 bytes) 20:44:51.292 CNTRLR [Node 016] [+] [Configuration] 101[1]: 1 20:44:51.292 CNTRLR [Node 016] [+] [Configuration] 101[16]: 1 20:44:51.293 CNTRLR [Node 016] [+] [Configuration] 101[32]: 1 20:44:51.293 CNTRLR [Node 016] [+] [Configuration] 101[64]: 1 20:44:51.294 CNTRLR [Node 016] [+] [Configuration] 101[128]: 1 20:44:51.294 SERIAL » [ACK] (0x06) 20:44:51.295 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 101 value size: 4 value: 241 20:44:51.296 CNTRLR « [Node 016] parameter #101 has value: 241 20:44:51.296 CNTRLR » [Node 016] querying parameter #102 value... 20:44:51.298 SERIAL » 0x010a0013100370056625ee2d (12 bytes) 20:44:51.298 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 238 └─[ConfigurationCCGet] parameter #: 102 20:44:51.300 SERIAL « [ACK] (0x06) 20:44:51.304 SERIAL « 0x0104011301e8 (6 bytes) 20:44:51.304 SERIAL » [ACK] (0x06) 20:44:51.305 DRIVER « [RES] [SendData] was sent: true 20:44:51.318 SERIAL « 0x01070013ee00000104 (9 bytes) 20:44:51.319 SERIAL » [ACK] (0x06) 20:44:51.319 DRIVER « [REQ] [SendData] callback id: 238 transmit status: OK 20:44:51.329 SERIAL « 0x010e00040010087006660400000000f9 (16 bytes) 20:44:51.330 CNTRLR [Node 016] [+] [Configuration] 102[1]: 0 20:44:51.330 CNTRLR [Node 016] [+] [Configuration] 102[16]: 0 20:44:51.331 CNTRLR [Node 016] [+] [Configuration] 102[32]: 0 20:44:51.331 CNTRLR [Node 016] [+] [Configuration] 102[64]: 0 20:44:51.331 CNTRLR [Node 016] [+] [Configuration] 102[128]: 0 20:44:51.331 SERIAL » [ACK] (0x06) 20:44:51.332 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 102 value size: 4 value: 0 20:44:51.332 CNTRLR « [Node 016] parameter #102 has value: 0 20:44:51.332 CNTRLR » [Node 016] querying parameter #103 value... 20:44:51.334 SERIAL » 0x010a0013100370056725ef2d (12 bytes) 20:44:51.334 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 239 └─[ConfigurationCCGet] parameter #: 103 20:44:51.335 SERIAL « [ACK] (0x06) 20:44:51.339 SERIAL « 0x0104011301e8 (6 bytes) 20:44:51.339 SERIAL » [ACK] (0x06) 20:44:51.339 DRIVER « [RES] [SendData] was sent: true 20:44:51.354 SERIAL « 0x01070013ef00000206 (9 bytes) 20:44:51.355 SERIAL » [ACK] (0x06) 20:44:51.355 DRIVER « [REQ] [SendData] callback id: 239 transmit status: OK 20:44:51.364 SERIAL « 0x010e00040010087006670400000000f8 (16 bytes) 20:44:51.371 CNTRLR [Node 016] [+] [Configuration] 103[1]: 0 20:44:51.372 CNTRLR [Node 016] [+] [Configuration] 103[16]: 0 20:44:51.372 CNTRLR [Node 016] [+] [Configuration] 103[32]: 0 20:44:51.373 CNTRLR [Node 016] [+] [Configuration] 103[64]: 0 20:44:51.374 CNTRLR [Node 016] [+] [Configuration] 103[128]: 0 20:44:51.374 SERIAL » [ACK] (0x06) 20:44:51.375 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 103 value size: 4 value: 0 20:44:51.376 CNTRLR « [Node 016] parameter #103 has value: 0 20:44:51.377 CNTRLR » [Node 016] querying parameter #41 value... 20:44:51.380 SERIAL » 0x010a0013100370052925f07c (12 bytes) 20:44:51.380 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 240 └─[ConfigurationCCGet] parameter #: 41 20:44:51.382 SERIAL « [ACK] (0x06) 20:44:51.385 SERIAL « 0x0104011301e8 (6 bytes) 20:44:51.385 SERIAL » [ACK] (0x06) 20:44:51.385 DRIVER « [RES] [SendData] was sent: true 20:44:51.400 SERIAL « 0x01070013f000000219 (9 bytes) 20:44:51.400 SERIAL » [ACK] (0x06) 20:44:51.400 DRIVER « [REQ] [SendData] callback id: 240 transmit status: OK 20:44:51.410 SERIAL « 0x010d000400100770062903001401a8 (15 bytes) 20:44:51.412 CNTRLR [Node 016] [+] [Configuration] 41[15]: 1 20:44:51.412 CNTRLR [Node 016] [+] [Configuration] 41[16776960]: 20 20:44:51.412 SERIAL » [ACK] (0x06) 20:44:51.413 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 41 value size: 3 value: 5121 20:44:51.413 CNTRLR « [Node 016] parameter #41 has value: 5121 20:44:51.413 CNTRLR [Node 016] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 20:44:51.416 CNTRLR [Node 016] AssociationCC: doing a complete interview... 20:44:51.417 CNTRLR » [Node 016] querying number of association groups... 20:44:51.418 SERIAL » 0x010900131002850525f1a3 (11 bytes) 20:44:51.419 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 241 └─[AssociationCCSupportedGroupingsGet] 20:44:51.420 SERIAL « [ACK] (0x06) 20:44:51.423 SERIAL « 0x0104011301e8 (6 bytes) 20:44:51.424 SERIAL » [ACK] (0x06) 20:44:51.424 DRIVER « [RES] [SendData] was sent: true 20:44:51.438 SERIAL « 0x01070013f10000011b (9 bytes) 20:44:51.439 SERIAL » [ACK] (0x06) 20:44:51.439 DRIVER « [REQ] [SendData] callback id: 241 transmit status: OK 20:44:51.448 SERIAL « 0x0109000400100385060163 (11 bytes) 20:44:51.449 CNTRLR [Node 016] [+] [Association] groupCount: 1 [Endpoint 0] [internal] 20:44:51.449 SERIAL » [ACK] (0x06) 20:44:51.449 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[AssociationCCSupportedGroupingsReport] group count: 1 20:44:51.450 CNTRLR « [Node 016] supports 1 association groups 20:44:51.450 CNTRLR » [Node 016] querying association group #1... 20:44:51.452 SERIAL » 0x010a0013100385020125f2a4 (12 bytes) 20:44:51.452 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 242 └─[AssociationCCGet] group id: 1 20:44:51.453 SERIAL « [ACK] (0x06) 20:44:51.457 SERIAL « 0x0104011301e8 (6 bytes) 20:44:51.457 SERIAL » [ACK] (0x06) 20:44:51.457 DRIVER « [RES] [SendData] was sent: true 20:44:51.472 SERIAL « 0x01070013f20000021b (9 bytes) 20:44:51.472 SERIAL » [ACK] (0x06) 20:44:51.473 DRIVER « [REQ] [SendData] callback id: 242 transmit status: OK 20:44:51.482 SERIAL « 0x010c000400100685030105000162 (14 bytes) 20:44:51.483 SERIAL » [ACK] (0x06) 20:44:51.484 CNTRLR [Node 016] [+] [Association] maxNodes[1]: 5 [internal] 20:44:51.485 CNTRLR [Node 016] [+] [Association] nodeIds[1]: 1 [internal] 20:44:51.485 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 1 max # of nodes: 5 node IDs: 1 reports to follow: 0 20:44:51.486 CNTRLR « [Node 016] received information for association group #1: maximum # of nodes: 5 currently assigned nodes: 1 20:44:51.487 CNTRLR [Node 016] [+] [Association] hasLifeline: true [internal] 20:44:51.487 CNTRLR [Node 016] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 20:44:51.488 CNTRLR [Node 016] AssociationGroupInfoCC: doing a complete interview... 20:44:51.488 CNTRLR » [Node 016] Association group #1: Querying name... 20:44:51.491 SERIAL » 0x010a0013100359010125f37a (12 bytes) 20:44:51.492 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 243 └─[AssociationGroupInfoCCNameGet] group id: 1 20:44:51.493 SERIAL « [ACK] (0x06) 20:44:51.497 SERIAL « 0x0104011301e8 (6 bytes) 20:44:51.497 SERIAL » [ACK] (0x06) 20:44:51.498 DRIVER « [RES] [SendData] was sent: true 20:44:51.512 SERIAL « 0x01070013f30000021a (9 bytes) 20:44:51.512 SERIAL » [ACK] (0x06) 20:44:51.513 DRIVER « [REQ] [SendData] callback id: 243 transmit status: OK 20:44:51.523 SERIAL « 0x0112000400100c590201084c6966656c696e658f (20 bytes) 20:44:51.524 CNTRLR [Node 016] [+] [Association Group Information] name[1]: "Lifeline" [internal] 20:44:51.524 SERIAL » [ACK] (0x06) 20:44:51.525 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 1 name: Lifeline 20:44:51.526 CNTRLR « [Node 016] Association group #1 has name "Lifeline" 20:44:51.526 CNTRLR » [Node 016] Association group #1: Querying info... 20:44:51.529 SERIAL » 0x010b001310045903000125f479 (13 bytes) 20:44:51.530 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 244 └─[AssociationGroupInfoCCInfoGet] group id: 1 refresh cache: false 20:44:51.531 SERIAL « [ACK] (0x06) 20:44:51.535 SERIAL « 0x0104011301e8 (6 bytes) 20:44:51.535 SERIAL » [ACK] (0x06) 20:44:51.536 DRIVER « [RES] [SendData] was sent: true 20:44:51.550 SERIAL « 0x01070013f40000021d (9 bytes) 20:44:51.550 SERIAL » [ACK] (0x06) 20:44:51.551 DRIVER « [REQ] [SendData] callback id: 244 transmit status: OK 20:44:51.561 SERIAL « 0x0110000400100a59040101000001000000ad (18 bytes) 20:44:51.562 CNTRLR [Node 016] [+] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false 20:44:51.562 CNTRLR [Node 016] [+] [Association Group Information] info[1]: [object Obj [internal] ect] 20:44:51.562 SERIAL » [ACK] (0x06) 20:44:51.563 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #1 mode: 0 profile: 1 event code: 0 20:44:51.564 CNTRLR « [Node 016] Received info for association group #1: info is dynamic: false profile: General: Lifeline 20:44:51.564 CNTRLR » [Node 016] Association group #1: Querying command list... 20:44:51.572 SERIAL » 0x010b001310045905800125f5fe (13 bytes) 20:44:51.572 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 245 └─[AssociationGroupInfoCCCommandListGet] group id: 1 allow cache: true 20:44:51.573 SERIAL « [ACK] (0x06) 20:44:51.578 SERIAL « 0x0104011301e8 (6 bytes) 20:44:51.578 SERIAL » [ACK] (0x06) 20:44:51.579 DRIVER « [RES] [SendData] was sent: true 20:44:51.593 SERIAL « 0x01070013f50000021c (9 bytes) 20:44:51.593 SERIAL » [ACK] (0x06) 20:44:51.594 DRIVER « [REQ] [SendData] callback id: 245 transmit status: OK 20:44:51.604 SERIAL « 0x011800040010125906010e2001300380033105710584075a01b8 (26 bytes) 20:44:51.605 CNTRLR [Node 016] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[1]: [object Map] 20:44:51.606 SERIAL » [ACK] (0x06) 20:44:51.606 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 1 commands: · Basic: 0x01 · Binary Sensor: 0x03 · Battery: 0x03 · Multilevel Sensor: 0x05 · Notification: 0x05 · Wake Up: 0x07 · Device Reset Locally: 0x01 20:44:51.608 CNTRLR [Node 016] [+] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true 20:44:51.613 CNTRLR [Node 016] NotificationCC: doing a complete interview... 20:44:51.614 CNTRLR » [Node 016] querying supported notification types... 20:44:51.617 SERIAL » 0x010900131002710725f652 (11 bytes) 20:44:51.617 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 246 └─[NotificationCCSupportedGet] 20:44:51.619 SERIAL « [ACK] (0x06) 20:44:51.623 SERIAL « 0x0104011301e8 (6 bytes) 20:44:51.623 SERIAL » [ACK] (0x06) 20:44:51.623 DRIVER « [RES] [SendData] was sent: true 20:44:51.638 SERIAL « 0x01070013f60000011c (9 bytes) 20:44:51.638 SERIAL » [ACK] (0x06) 20:44:51.639 DRIVER « [REQ] [SendData] callback id: 246 transmit status: OK 20:44:51.648 SERIAL « 0x010a0004001004710801801d (12 bytes) 20:44:51.649 CNTRLR [Node 016] [+] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" 20:44:51.649 CNTRLR [Node 016] [+] [Notification] supportedNotificationTyp [Endpoint 0] [internal] es: 7 20:44:51.649 CNTRLR [Node 016] [+] [Notification] supportsV1Alarm: false [Endpoint 0] [internal] 20:44:51.649 CNTRLR [Node 016] [~] [Notification] supportedNotificationTyp [Endpoint 0] [internal] es: 7 => 7 20:44:51.649 SERIAL » [ACK] (0x06) 20:44:51.651 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[NotificationCCSupportedReport] supports V1 alarm: false supported notification types: · Home Security 20:44:51.654 CNTRLR « [Node 016] received supported notification types: · Home Security 20:44:51.654 CNTRLR » [Node 016] querying supported notification events for Home Security... 20:44:51.661 SERIAL » 0x010a0013100371010725f750 (12 bytes) 20:44:51.661 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 247 └─[NotificationCCEventSupportedGet] notification type: Home Security 20:44:51.671 SERIAL « [ACK] (0x06) 20:44:51.672 SERIAL « 0x0104011301e8 (6 bytes) 20:44:51.672 SERIAL » [ACK] (0x06) 20:44:51.673 DRIVER « [RES] [SendData] was sent: true 20:44:51.682 SERIAL « 0x01070013f70000021e (9 bytes) 20:44:51.682 SERIAL » [ACK] (0x06) 20:44:51.682 DRIVER « [REQ] [SendData] callback id: 247 transmit status: OK 20:44:51.692 SERIAL « 0x010c00040010067102070208019e (14 bytes) 20:44:51.694 CNTRLR [Node 016] [~] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" => "unknown" 20:44:51.694 CNTRLR [Node 016] [+] [Notification] supportedNotificationEvents[7]: 3,8 [internal] 20:44:51.694 CNTRLR [Node 016] [Notification] Home Security[Cover status]: metadata u [Endpoint 0] pdated 20:44:51.695 CNTRLR [Node 016] [Notification] Home Security[Motion sensor status]: me [Endpoint 0] tadata updated 20:44:51.699 SERIAL » [ACK] (0x06) 20:44:51.700 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[NotificationCCEventSupportedReport] notification type: Home Security supported events: · Unknown (0x03) · Unknown (0x08) 20:44:51.701 CNTRLR « [Node 016] received supported notification events for Home Security: 3, 8 20:44:51.702 CNTRLR [Node 016] [+] [Notification] interviewComplete: true [Endpoint 0] [internal] 20:44:51.702 CNTRLR [Node 016] Interview stage completed: CommandClasses 20:44:51.702 CNTRLR [Node 016] Interview stage completed: OverwriteConfig 20:44:51.702 CNTRLR » [Node 016] requesting node neighbors... 20:44:51.704 SERIAL » 0x010700801000000068 (9 bytes) 20:44:51.704 DRIVER » [Node 016] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 20:44:51.705 SERIAL « [ACK] (0x06) 20:44:51.707 SERIAL « 0x01200180170000000000000000000000000000000000000000000000000000000 (34 bytes) 049 20:44:51.707 SERIAL » [ACK] (0x06) 20:44:51.707 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 2, 3, 5 20:44:51.708 CNTRLR « [Node 016] node neighbors received: 1, 2, 3, 5 20:44:51.708 CNTRLR [Node 016] Interview stage completed: Neighbors 20:44:51.708 CNTRLR [Node 016] Interview completed 20:44:51.709 CNTRLR [Node 016] The node is ready to be used 20:44:52.709 CNTRLR » [Node 016] Sending node back to sleep... 20:44:52.714 SERIAL » 0x010900131002840825f8a6 (11 bytes) 20:44:52.714 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 248 └─[WakeUpCCNoMoreInformation] 20:44:52.715 SERIAL « [ACK] (0x06) 20:44:52.719 SERIAL « 0x0104011301e8 (6 bytes) 20:44:52.719 SERIAL » [ACK] (0x06) 20:44:52.720 DRIVER « [RES] [SendData] was sent: true 20:44:52.734 SERIAL « 0x01070013f800000211 (9 bytes) 20:44:52.734 SERIAL » [ACK] (0x06) 20:44:52.735 DRIVER « [REQ] [SendData] callback id: 248 transmit status: OK 20:44:52.736 CNTRLR [Node 016] The node is now asleep. 20:44:52.737 CNTRLR [Node 016] Node asleep 20:45:06.948 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:45:06.949 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:45:06.950 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:45:06.950 SERIAL » [ACK] (0x06) 20:45:06.951 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:45:09.894 SERIAL « 0x010c0004001a063105042207d32d (14 bytes) 20:45:09.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:45:09.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 254 => 200.3 [Endpoint 0] 20:45:09.896 SERIAL » [ACK] (0x06) 20:45:09.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 200.3 20:45:10.894 SERIAL « 0x010c0004001a0631050422090dfd (14 bytes) 20:45:10.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:45:10.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 200.3 => 231.7 [Endpoint 0] 20:45:10.896 SERIAL » [ACK] (0x06) 20:45:10.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 231.7 20:45:14.825 SERIAL « 0x010c0004001c063105042202867b (14 bytes) 20:45:14.826 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:45:14.826 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 56 => 64.6 [Endpoint 0] 20:45:14.827 SERIAL » [ACK] (0x06) 20:45:14.827 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 64.6 20:45:24.894 SERIAL « 0x010c0004001a063105042206708f (14 bytes) 20:45:24.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:45:24.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 231.7 => 164.8 [Endpoint 0] 20:45:24.896 SERIAL » [ACK] (0x06) 20:45:24.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 164.8 20:45:27.262 SERIAL « 0x0109000400110380035a39 (11 bytes) 20:45:27.263 CNTRLR [Node 017] [~] [Battery] level: 90 => 90 [Endpoint 0] 20:45:27.263 CNTRLR [Node 017] [~] [Battery] isLow: false => false [Endpoint 0] 20:45:27.264 SERIAL » [ACK] (0x06) 20:45:27.265 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 90 is low: false 20:45:27.320 SERIAL « 0x010c000400110643030142076c88 (14 bytes) 20:45:27.321 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpoint[1]: 19 => 19 [Endpoint 0] 20:45:27.322 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 20:45:27.322 SERIAL » [ACK] (0x06) 20:45:27.323 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 20:45:27.375 SERIAL « 0x010a00040011044608007fd5 (12 bytes) 20:45:27.376 CNTRLR [Node 017] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 20:45:27.377 CNTRLR [Node 017] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 20:45:27.377 SERIAL » [ACK] (0x06) 20:45:27.378 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ClimateControlScheduleCCOverrideReport] override type: None override state: Unused 20:45:27.429 SERIAL « 0x01080004001102840763 (10 bytes) 20:45:27.429 SERIAL » [ACK] (0x06) 20:45:27.430 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 20:45:27.431 CNTRLR « [Node 017] received wakeup notification 20:45:27.431 CNTRLR [Node 017] The node is now awake. 20:45:27.433 CNTRLR [Node 017] expects some queries after wake up, so it shall receive 20:45:27.433 CNTRLR [Node 017] compat query "Battery"::get() 20:45:27.438 SERIAL » 0x010900131102800225f9a8 (11 bytes) 20:45:27.438 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 249 └─[BatteryCCGet] 20:45:27.441 SERIAL « [ACK] (0x06) 20:45:27.444 SERIAL « 0x0104011301e8 (6 bytes) 20:45:27.444 SERIAL » [ACK] (0x06) 20:45:27.445 DRIVER « [RES] [SendData] was sent: true 20:45:27.471 SERIAL « 0x01070013f900000311 (9 bytes) 20:45:27.472 SERIAL » [ACK] (0x06) 20:45:27.472 DRIVER « [REQ] [SendData] callback id: 249 transmit status: OK 20:45:27.480 SERIAL « 0x0109000400110380035a39 (11 bytes) 20:45:27.481 CNTRLR [Node 017] [~] [Battery] level: 90 => 90 [Endpoint 0] 20:45:27.481 CNTRLR [Node 017] [~] [Battery] isLow: false => false [Endpoint 0] 20:45:27.482 SERIAL » [ACK] (0x06) 20:45:27.483 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 90 is low: false 20:45:27.484 CNTRLR [Node 017] API call successful 20:45:27.485 CNTRLR [Node 017] compat query "Thermostat Setpoint"::get(1) 20:45:27.490 SERIAL » 0x010a0013110343020125fa6b (12 bytes) 20:45:27.491 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 250 └─[ThermostatSetpointCCGet] setpoint type: Heating 20:45:27.494 SERIAL « [ACK] (0x06) 20:45:27.497 SERIAL « 0x0104011301e8 (6 bytes) 20:45:27.497 SERIAL » [ACK] (0x06) 20:45:27.497 DRIVER « [RES] [SendData] was sent: true 20:45:27.512 SERIAL « 0x01070013fa00000213 (9 bytes) 20:45:27.512 SERIAL » [ACK] (0x06) 20:45:27.513 DRIVER « [REQ] [SendData] callback id: 250 transmit status: OK 20:45:27.522 SERIAL « 0x010c000400110643030142076c88 (14 bytes) 20:45:27.523 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpoint[1]: 19 => 19 [Endpoint 0] 20:45:27.524 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 20:45:27.524 SERIAL » [ACK] (0x06) 20:45:27.525 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 20:45:27.528 CNTRLR [Node 017] API call successful 20:45:28.529 CNTRLR » [Node 017] Sending node back to sleep... 20:45:28.533 SERIAL » 0x010900131102840825fba4 (11 bytes) 20:45:28.533 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 251 └─[WakeUpCCNoMoreInformation] 20:45:28.534 SERIAL « [ACK] (0x06) 20:45:28.538 SERIAL « 0x0104011301e8 (6 bytes) 20:45:28.538 SERIAL » [ACK] (0x06) 20:45:28.539 DRIVER « [RES] [SendData] was sent: true 20:45:28.554 SERIAL « 0x01070013fb00000212 (9 bytes) 20:45:28.554 SERIAL » [ACK] (0x06) 20:45:28.555 DRIVER « [REQ] [SendData] callback id: 251 transmit status: OK 20:45:28.558 CNTRLR [Node 017] The node is now asleep. 20:45:28.559 CNTRLR [Node 017] Node asleep 20:45:28.825 SERIAL « 0x010c0004001c06310504220207fa (14 bytes) 20:45:28.826 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:45:28.826 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 64.6 => 51.9 [Endpoint 0] 20:45:28.827 SERIAL » [ACK] (0x06) 20:45:28.828 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 51.9 20:45:28.894 SERIAL « 0x010c0004001a0631050422086796 (14 bytes) 20:45:28.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:45:28.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 164.8 => 215.1 [Endpoint 0] 20:45:28.896 SERIAL » [ACK] (0x06) 20:45:28.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 215.1 20:45:30.825 SERIAL « 0x010c0004001c0631050422028e73 (14 bytes) 20:45:30.829 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:45:30.829 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 51.9 => 65.4 [Endpoint 0] 20:45:30.830 SERIAL » [ACK] (0x06) 20:45:30.831 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 65.4 20:45:33.825 SERIAL « 0x010c0004001c0631050422022bd6 (14 bytes) 20:45:33.826 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:45:33.826 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 65.4 => 55.5 [Endpoint 0] 20:45:33.827 SERIAL » [ACK] (0x06) 20:45:33.827 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 55.5 20:46:06.825 SERIAL « 0x010c0004001c0631050422029f62 (14 bytes) 20:46:06.826 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:46:06.827 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 55.5 => 67.1 [Endpoint 0] 20:46:06.827 SERIAL » [ACK] (0x06) 20:46:06.828 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 67.1 20:46:17.825 SERIAL « 0x010c0004001c0631050422030af6 (14 bytes) 20:46:17.826 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:46:17.826 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 67.1 => 77.8 [Endpoint 0] 20:46:17.827 SERIAL » [ACK] (0x06) 20:46:17.827 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 77.8 20:46:20.825 SERIAL « 0x010c0004001c063105042202936e (14 bytes) 20:46:20.826 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:46:20.827 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 77.8 => 65.9 [Endpoint 0] 20:46:20.827 SERIAL » [ACK] (0x06) 20:46:20.828 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 65.9 20:46:43.269 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:46:43.270 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:46:43.271 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:46:43.271 SERIAL » [ACK] (0x06) 20:46:43.272 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:46:51.825 SERIAL « 0x010c0004001c0631050422022fd2 (14 bytes) 20:46:51.825 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:46:51.826 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 65.9 => 55.9 [Endpoint 0] 20:46:51.826 SERIAL » [ACK] (0x06) 20:46:51.827 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 55.9 20:47:13.825 SERIAL « 0x010c0004001c0631050422029469 (14 bytes) 20:47:13.828 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:47:13.828 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 55.9 => 66 [Endpoint 0] 20:47:13.829 SERIAL » [ACK] (0x06) 20:47:13.829 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 66 20:47:32.895 SERIAL « 0x010c0004001a063105042209af5f (14 bytes) 20:47:32.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:47:32.897 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 215.1 => 247.9 [Endpoint 0] 20:47:32.897 SERIAL » [ACK] (0x06) 20:47:32.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 247.9 20:48:00.824 SERIAL « 0x010c0004001c063105042201f806 (14 bytes) 20:48:00.825 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:48:00.825 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 66 => 50.4 [Endpoint 0] 20:48:00.826 SERIAL » [ACK] (0x06) 20:48:00.826 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 50.4 20:48:06.824 SERIAL « 0x010c0004001c0631050422028d70 (14 bytes) 20:48:06.825 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:48:06.825 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 50.4 => 65.3 [Endpoint 0] 20:48:06.826 SERIAL » [ACK] (0x06) 20:48:06.826 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 65.3 20:48:07.824 SERIAL « 0x010c0004001c0631050422035ea2 (14 bytes) 20:48:07.824 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:48:07.825 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 65.3 => 86.2 [Endpoint 0] 20:48:07.825 SERIAL » [ACK] (0x06) 20:48:07.826 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 86.2 20:48:19.591 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:48:19.592 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:48:19.592 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:48:19.593 SERIAL » [ACK] (0x06) 20:48:19.594 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:48:45.823 SERIAL « 0x010c0004001c063105042202d924 (14 bytes) 20:48:45.824 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:48:45.825 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 86.2 => 72.9 [Endpoint 0] 20:48:45.825 SERIAL » [ACK] (0x06) 20:48:45.826 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 72.9 20:48:56.847 SERIAL « 0x0110000400060a32022134000000000000c2 (18 bytes) 20:48:56.848 CNTRLR [Node 006] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:48:56.849 CNTRLR [Node 006] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:48:56.849 SERIAL » [ACK] (0x06) 20:48:56.850 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:49:44.823 SERIAL « 0x010c0004001c0631050422025fa2 (14 bytes) 20:49:44.823 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:49:44.824 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 72.9 => 60.7 [Endpoint 0] 20:49:44.824 SERIAL » [ACK] (0x06) 20:49:44.825 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 60.7 20:49:54.017 SERIAL « 0x0110000400120a32022134000000010000d7 (18 bytes) 20:49:54.018 CNTRLR [Node 018] [~] [Meter] value[66049]: 0.1 => 0.1 [Endpoint 0] 20:49:54.019 CNTRLR [Node 018] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:49:54.019 SERIAL » [ACK] (0x06) 20:49:54.020 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0.1 time delta: 0 seconds 20:49:55.912 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:49:55.913 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:49:55.914 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:49:55.914 SERIAL » [ACK] (0x06) 20:49:55.915 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:50:22.063 SERIAL « 0x0109000400110380035a39 (11 bytes) 20:50:22.064 CNTRLR [Node 017] [~] [Battery] level: 90 => 90 [Endpoint 0] 20:50:22.065 CNTRLR [Node 017] [~] [Battery] isLow: false => false [Endpoint 0] 20:50:22.065 SERIAL » [ACK] (0x06) 20:50:22.068 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 90 is low: false 20:50:22.121 SERIAL « 0x010c000400110643030142076c88 (14 bytes) 20:50:22.122 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpoint[1]: 19 => 19 [Endpoint 0] 20:50:22.122 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 20:50:22.123 SERIAL » [ACK] (0x06) 20:50:22.123 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 20:50:22.177 SERIAL « 0x010a00040011044608007fd5 (12 bytes) 20:50:22.177 CNTRLR [Node 017] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 20:50:22.178 CNTRLR [Node 017] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 20:50:22.178 SERIAL » [ACK] (0x06) 20:50:22.179 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ClimateControlScheduleCCOverrideReport] override type: None override state: Unused 20:50:22.230 SERIAL « 0x01080004001102840763 (10 bytes) 20:50:22.231 SERIAL » [ACK] (0x06) 20:50:22.231 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 20:50:22.234 CNTRLR « [Node 017] received wakeup notification 20:50:22.234 CNTRLR [Node 017] The node is now awake. 20:50:22.235 CNTRLR [Node 017] expects some queries after wake up, so it shall receive 20:50:22.235 CNTRLR [Node 017] compat query "Battery"::get() 20:50:22.239 SERIAL » 0x010900131102800225fcad (11 bytes) 20:50:22.240 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 252 └─[BatteryCCGet] 20:50:22.241 SERIAL « [ACK] (0x06) 20:50:22.245 SERIAL « 0x0104011301e8 (6 bytes) 20:50:22.245 SERIAL » [ACK] (0x06) 20:50:22.246 DRIVER « [RES] [SendData] was sent: true 20:50:22.272 SERIAL « 0x01070013fc00000314 (9 bytes) 20:50:22.273 SERIAL » [ACK] (0x06) 20:50:22.273 DRIVER « [REQ] [SendData] callback id: 252 transmit status: OK 20:50:22.281 SERIAL « 0x0109000400110380035a39 (11 bytes) 20:50:22.282 CNTRLR [Node 017] [~] [Battery] level: 90 => 90 [Endpoint 0] 20:50:22.283 CNTRLR [Node 017] [~] [Battery] isLow: false => false [Endpoint 0] 20:50:22.283 SERIAL » [ACK] (0x06) 20:50:22.284 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 90 is low: false 20:50:22.285 CNTRLR [Node 017] API call successful 20:50:22.285 CNTRLR [Node 017] compat query "Thermostat Setpoint"::get(1) 20:50:22.289 SERIAL » 0x010a0013110343020125fd6c (12 bytes) 20:50:22.289 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 253 └─[ThermostatSetpointCCGet] setpoint type: Heating 20:50:22.291 SERIAL « [ACK] (0x06) 20:50:22.295 SERIAL « 0x0104011301e8 (6 bytes) 20:50:22.295 SERIAL » [ACK] (0x06) 20:50:22.297 DRIVER « [RES] [SendData] was sent: true 20:50:22.311 SERIAL « 0x01070013fd00000214 (9 bytes) 20:50:22.311 SERIAL » [ACK] (0x06) 20:50:22.312 DRIVER « [REQ] [SendData] callback id: 253 transmit status: OK 20:50:22.320 SERIAL « 0x010c000400110643030142076c88 (14 bytes) 20:50:22.321 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpoint[1]: 19 => 19 [Endpoint 0] 20:50:22.322 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 20:50:22.322 SERIAL » [ACK] (0x06) 20:50:22.323 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 20:50:22.324 CNTRLR [Node 017] API call successful 20:50:23.325 CNTRLR » [Node 017] Sending node back to sleep... 20:50:23.331 SERIAL » 0x010900131102840825fea1 (11 bytes) 20:50:23.331 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 254 └─[WakeUpCCNoMoreInformation] 20:50:23.333 SERIAL « [ACK] (0x06) 20:50:23.337 SERIAL « 0x0104011301e8 (6 bytes) 20:50:23.337 SERIAL » [ACK] (0x06) 20:50:23.338 DRIVER « [RES] [SendData] was sent: true 20:50:23.353 SERIAL « 0x01070013fe00000217 (9 bytes) 20:50:23.353 SERIAL » [ACK] (0x06) 20:50:23.354 DRIVER « [REQ] [SendData] callback id: 254 transmit status: OK 20:50:23.356 CNTRLR [Node 017] The node is now asleep. 20:50:23.357 CNTRLR [Node 017] Node asleep 20:50:46.822 SERIAL « 0x010c0004001c063105042202c934 (14 bytes) 20:50:46.823 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:50:46.823 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 60.7 => 71.3 [Endpoint 0] 20:50:46.824 SERIAL » [ACK] (0x06) 20:50:46.825 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 71.3 20:50:49.822 SERIAL « 0x010c0004001c0631050422034fb3 (14 bytes) 20:50:49.823 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:50:49.823 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 71.3 => 84.7 [Endpoint 0] 20:50:49.824 SERIAL » [ACK] (0x06) 20:50:49.824 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 84.7 20:50:54.822 SERIAL « 0x010c0004001c063105042202ae53 (14 bytes) 20:50:54.823 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:50:54.823 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 84.7 => 68.6 [Endpoint 0] 20:50:54.824 SERIAL » [ACK] (0x06) 20:50:54.825 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 68.6 20:51:07.100 SERIAL « 0x01080004000c0284077e (10 bytes) 20:51:07.101 SERIAL » [ACK] (0x06) 20:51:07.101 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 20:51:07.103 CNTRLR « [Node 012] received wakeup notification 20:51:07.104 CNTRLR [Node 012] The node is now awake. 20:51:07.107 SERIAL » 0x010400600c97 (6 bytes) 20:51:07.107 DRIVER » [Node 012] [REQ] [RequestNodeInfo] payload: 0x0c 20:51:07.109 SERIAL « [ACK] (0x06) 20:51:07.112 SERIAL « 0x01040160019b (6 bytes) 20:51:07.113 SERIAL » [ACK] (0x06) 20:51:07.113 DRIVER « [RES] [RequestNodeInfo] payload: 0x01 20:51:07.145 SERIAL « 0x011b0049840c150407015e80718570728630318459735a8f987aef20cb (29 bytes) 20:51:07.145 SERIAL » [ACK] (0x06) 20:51:07.146 DRIVER « [Node 012] [REQ] [ApplicationUpdateRequest] payload: 0x840c150407015e80718570728630318459735a8f987aef20 20:51:07.150 CNTRLR « [Node 012] node info received supported CCs: · Z-Wave Plus Info · Battery · Notification · Association · Configuration · Manufacturer Specific · Version · Binary Sensor · Multilevel Sensor · Wake Up · Association Group Information · Powerlevel · Device Reset Locally · Multi Command · Security · Firmware Update Meta Data controlled CCs: · Basic 20:51:07.157 CNTRLR [Node 012] Interview stage completed: NodeInfo 20:51:07.157 CNTRLR » [Node 012] querying securely supported commands... 20:51:07.167 SERIAL » 0x010900130c02984025ffe9 (11 bytes) 20:51:07.168 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 255 └─[SecurityCCNonceGet] 20:51:07.169 SERIAL « [ACK] (0x06) 20:51:07.173 SERIAL « 0x0104011301e8 (6 bytes) 20:51:07.174 SERIAL » [ACK] (0x06) 20:51:07.174 DRIVER « [RES] [SendData] was sent: true 20:51:07.188 SERIAL « 0x01070013ff00000115 (9 bytes) 20:51:07.188 SERIAL » [ACK] (0x06) 20:51:07.189 DRIVER « [REQ] [SendData] callback id: 255 transmit status: OK 20:51:08.795 CNTRLR [Node 012] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 20:51:09.300 SERIAL » 0x010900130c029840250117 (11 bytes) 20:51:09.301 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 1 └─[SecurityCCNonceGet] 20:51:09.302 SERIAL « [ACK] (0x06) 20:51:09.306 SERIAL « 0x0104011301e8 (6 bytes) 20:51:09.306 SERIAL » [ACK] (0x06) 20:51:09.306 DRIVER « [RES] [SendData] was sent: true 20:51:09.321 SERIAL « 0x0107001301000002e8 (9 bytes) 20:51:09.321 SERIAL » [ACK] (0x06) 20:51:09.323 DRIVER « [REQ] [SendData] callback id: 1 transmit status: OK 20:51:10.925 CNTRLR [Node 012] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 20:51:11.429 SERIAL » 0x010900130c029840250214 (11 bytes) 20:51:11.430 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 2 └─[SecurityCCNonceGet] 20:51:11.431 SERIAL « [ACK] (0x06) 20:51:11.435 SERIAL « 0x0104011301e8 (6 bytes) 20:51:11.435 SERIAL » [ACK] (0x06) 20:51:11.435 DRIVER « [RES] [SendData] was sent: true 20:51:11.450 SERIAL « 0x0107001302000002eb (9 bytes) 20:51:11.450 SERIAL » [ACK] (0x06) 20:51:11.451 DRIVER « [REQ] [SendData] callback id: 2 transmit status: OK 20:51:13.055 CNTRLR [Node 012] The node is not included securely. Continuing interview non-securel y. 20:51:13.057 CNTRLR [Node 012] ManufacturerSpecificCC: doing a complete interview... 20:51:13.057 CNTRLR » [Node 012] querying manufacturer information... 20:51:13.061 SERIAL » 0x010900130c0272042503bb (11 bytes) 20:51:13.061 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 3 └─[ManufacturerSpecificCCGet] 20:51:13.062 SERIAL « [ACK] (0x06) 20:51:13.066 SERIAL « 0x0104011301e8 (6 bytes) 20:51:13.067 SERIAL » [ACK] (0x06) 20:51:13.067 DRIVER « [RES] [SendData] was sent: true 20:51:13.081 SERIAL « 0x0107001303000002ea (9 bytes) 20:51:13.082 SERIAL » [ACK] (0x06) 20:51:13.082 DRIVER « [REQ] [SendData] callback id: 3 transmit status: OK 20:51:13.096 SERIAL « 0x010e0004000c08720501750002000efe (16 bytes) 20:51:13.097 CNTRLR [Node 012] [+] [Manufacturer Specific] manufacturerId: 373 [Endpoint 0] 20:51:13.097 CNTRLR [Node 012] [+] [Manufacturer Specific] productType: 2 [Endpoint 0] 20:51:13.098 CNTRLR [Node 012] [+] [Manufacturer Specific] productId: 14 [Endpoint 0] 20:51:13.098 SERIAL » [ACK] (0x06) 20:51:13.099 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ManufacturerSpecificCCReport] manufacturer id: 0x0175 product type: 0x02 product id: 0x0e 20:51:13.101 CNTRLR « [Node 012] received response for manufacturer information: manufacturer: Devolo (0x0175) product type: 0x02 product id: 0x0e 20:51:13.101 CNTRLR [Node 012] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 20:51:13.111 CNTRLR [Node 012] VersionCC: doing a complete interview... 20:51:13.111 CNTRLR » [Node 012] querying node versions... 20:51:13.115 SERIAL » 0x010900130c02861125045d (11 bytes) 20:51:13.117 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 4 └─[VersionCCGet] 20:51:13.119 SERIAL « [ACK] (0x06) 20:51:13.123 SERIAL « 0x0104011301e8 (6 bytes) 20:51:13.123 SERIAL » [ACK] (0x06) 20:51:13.124 DRIVER « [RES] [SendData] was sent: true 20:51:13.137 SERIAL « 0x0107001304000001ee (9 bytes) 20:51:13.138 SERIAL » [ACK] (0x06) 20:51:13.138 DRIVER « [REQ] [SendData] callback id: 4 transmit status: OK 20:51:13.152 SERIAL « 0x01110004000c0b861203035f010c0101010c26 (19 bytes) 20:51:13.153 CNTRLR [Node 012] [+] [Version] libraryType: 3 [Endpoint 0] 20:51:13.154 CNTRLR [Node 012] [+] [Version] protocolVersion: "3.95" [Endpoint 0] 20:51:13.154 CNTRLR [Node 012] [+] [Version] firmwareVersions: 1.12 [Endpoint 0] 20:51:13.155 SERIAL » [ACK] (0x06) 20:51:13.158 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[VersionCCReport] library type: Enhanced Slave protocol version: 3.95 firmware versions: 1.12 20:51:13.160 CNTRLR « [Node 012] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 3.95 firmware versions: 1.12 20:51:13.160 CNTRLR » [Node 012] querying CC versions... 20:51:13.160 CNTRLR » [Node 012] querying the CC version for Wake Up (0x84)... 20:51:13.166 SERIAL » 0x010a00130c038613842505d8 (12 bytes) 20:51:13.166 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 5 └─[VersionCCCommandClassGet] CC: Wake Up 20:51:13.168 SERIAL « [ACK] (0x06) 20:51:13.171 SERIAL « 0x0104011301e8 (6 bytes) 20:51:13.172 SERIAL » [ACK] (0x06) 20:51:13.172 DRIVER « [RES] [SendData] was sent: true 20:51:13.186 SERIAL « 0x0107001305000002ec (9 bytes) 20:51:13.187 SERIAL » [ACK] (0x06) 20:51:13.187 DRIVER « [REQ] [SendData] callback id: 5 transmit status: OK 20:51:13.200 SERIAL « 0x010a0004000c0486148402ed (12 bytes) 20:51:13.202 SERIAL » [ACK] (0x06) 20:51:13.203 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Wake Up version: 2 20:51:13.204 CNTRLR [Node 012] supports CC Wake Up (0x84) in version 2 20:51:13.204 CNTRLR » [Node 012] querying the CC version for Z-Wave Plus Info (0x5e)... 20:51:13.208 SERIAL » 0x010a00130c0386135e250601 (12 bytes) 20:51:13.208 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 6 └─[VersionCCCommandClassGet] CC: Z-Wave Plus Info 20:51:13.209 SERIAL « [ACK] (0x06) 20:51:13.213 SERIAL « 0x0104011301e8 (6 bytes) 20:51:13.214 SERIAL » [ACK] (0x06) 20:51:13.214 DRIVER « [RES] [SendData] was sent: true 20:51:13.228 SERIAL « 0x0107001306000001ec (9 bytes) 20:51:13.229 SERIAL » [ACK] (0x06) 20:51:13.229 DRIVER « [REQ] [SendData] callback id: 6 transmit status: OK 20:51:13.242 SERIAL « 0x010a0004000c0486145e0237 (12 bytes) 20:51:13.243 SERIAL » [ACK] (0x06) 20:51:13.243 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Z-Wave Plus Info version: 2 20:51:13.244 CNTRLR [Node 012] supports CC Z-Wave Plus Info (0x5e) in version 2 20:51:13.245 CNTRLR » [Node 012] querying the CC version for Battery (0x80)... 20:51:13.248 SERIAL » 0x010a00130c038613802507de (12 bytes) 20:51:13.248 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 7 └─[VersionCCCommandClassGet] CC: Battery 20:51:13.250 SERIAL « [ACK] (0x06) 20:51:13.254 SERIAL « 0x0104011301e8 (6 bytes) 20:51:13.254 SERIAL » [ACK] (0x06) 20:51:13.255 DRIVER « [RES] [SendData] was sent: true 20:51:13.269 SERIAL « 0x0107001307000002ee (9 bytes) 20:51:13.269 SERIAL » [ACK] (0x06) 20:51:13.269 DRIVER « [REQ] [SendData] callback id: 7 transmit status: OK 20:51:13.283 SERIAL « 0x010a0004000c0486148001ea (12 bytes) 20:51:13.283 SERIAL » [ACK] (0x06) 20:51:13.284 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Battery version: 1 20:51:13.285 CNTRLR [Node 012] supports CC Battery (0x80) in version 1 20:51:13.285 CNTRLR » [Node 012] querying the CC version for Notification (0x71)... 20:51:13.288 SERIAL » 0x010a00130c03861371250820 (12 bytes) 20:51:13.289 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 8 └─[VersionCCCommandClassGet] CC: Notification 20:51:13.290 SERIAL « [ACK] (0x06) 20:51:13.294 SERIAL « 0x0104011301e8 (6 bytes) 20:51:13.295 SERIAL » [ACK] (0x06) 20:51:13.295 DRIVER « [RES] [SendData] was sent: true 20:51:13.309 SERIAL « 0x0107001308000002e1 (9 bytes) 20:51:13.309 SERIAL » [ACK] (0x06) 20:51:13.310 DRIVER « [REQ] [SendData] callback id: 8 transmit status: OK 20:51:13.323 SERIAL « 0x010a0004000c04861471041e (12 bytes) 20:51:13.324 SERIAL » [ACK] (0x06) 20:51:13.324 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Notification version: 4 20:51:13.326 CNTRLR [Node 012] supports CC Notification (0x71) in version 4 20:51:13.326 CNTRLR » [Node 012] querying the CC version for Association (0x85)... 20:51:13.331 SERIAL » 0x010a00130c038613852509d5 (12 bytes) 20:51:13.332 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 9 └─[VersionCCCommandClassGet] CC: Association 20:51:13.333 SERIAL « [ACK] (0x06) 20:51:13.337 SERIAL « 0x0104011301e8 (6 bytes) 20:51:13.337 SERIAL » [ACK] (0x06) 20:51:13.338 DRIVER « [RES] [SendData] was sent: true 20:51:13.352 SERIAL « 0x0107001309000002e0 (9 bytes) 20:51:13.352 SERIAL » [ACK] (0x06) 20:51:13.353 DRIVER « [REQ] [SendData] callback id: 9 transmit status: OK 20:51:13.366 SERIAL « 0x010a0004000c0486148502ec (12 bytes) 20:51:13.366 SERIAL » [ACK] (0x06) 20:51:13.367 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association version: 2 20:51:13.368 CNTRLR [Node 012] supports CC Association (0x85) in version 2 20:51:13.368 CNTRLR » [Node 012] querying the CC version for Configuration (0x70)... 20:51:13.372 SERIAL » 0x010a00130c03861370250a23 (12 bytes) 20:51:13.373 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 10 └─[VersionCCCommandClassGet] CC: Configuration 20:51:13.374 SERIAL « [ACK] (0x06) 20:51:13.378 SERIAL « 0x0104011301e8 (6 bytes) 20:51:13.379 SERIAL » [ACK] (0x06) 20:51:13.379 DRIVER « [RES] [SendData] was sent: true 20:51:13.393 SERIAL « 0x010700130a000002e3 (9 bytes) 20:51:13.393 SERIAL » [ACK] (0x06) 20:51:13.394 DRIVER « [REQ] [SendData] callback id: 10 transmit status: OK 20:51:13.407 SERIAL « 0x010a0004000c04861470011a (12 bytes) 20:51:13.407 SERIAL » [ACK] (0x06) 20:51:13.408 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Configuration version: 1 20:51:13.412 CNTRLR [Node 012] supports CC Configuration (0x70) in version 1 20:51:13.412 CNTRLR » [Node 012] querying the CC version for Manufacturer Specific (0x72)... 20:51:13.419 SERIAL » 0x010a00130c03861372250b20 (12 bytes) 20:51:13.420 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 11 └─[VersionCCCommandClassGet] CC: Manufacturer Specific 20:51:13.421 SERIAL « [ACK] (0x06) 20:51:13.425 SERIAL « 0x0104011301e8 (6 bytes) 20:51:13.425 SERIAL » [ACK] (0x06) 20:51:13.426 DRIVER « [RES] [SendData] was sent: true 20:51:13.440 SERIAL « 0x010700130b000002e2 (9 bytes) 20:51:13.441 SERIAL » [ACK] (0x06) 20:51:13.441 DRIVER « [REQ] [SendData] callback id: 11 transmit status: OK 20:51:13.454 SERIAL « 0x010a0004000c04861472021b (12 bytes) 20:51:13.454 SERIAL » [ACK] (0x06) 20:51:13.455 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 2 20:51:13.456 CNTRLR [Node 012] supports CC Manufacturer Specific (0x72) in version 2 20:51:13.456 CNTRLR » [Node 012] querying the CC version for Version (0x86)... 20:51:13.460 SERIAL » 0x010a00130c03861386250cd3 (12 bytes) 20:51:13.461 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 12 └─[VersionCCCommandClassGet] CC: Version 20:51:13.462 SERIAL « [ACK] (0x06) 20:51:13.466 SERIAL « 0x0104011301e8 (6 bytes) 20:51:13.466 SERIAL » [ACK] (0x06) 20:51:13.467 DRIVER « [RES] [SendData] was sent: true 20:51:13.481 SERIAL « 0x010700130c000002e5 (9 bytes) 20:51:13.482 SERIAL » [ACK] (0x06) 20:51:13.484 DRIVER « [REQ] [SendData] callback id: 12 transmit status: OK 20:51:13.495 SERIAL « 0x010a0004000c0486148602ef (12 bytes) 20:51:13.496 SERIAL » [ACK] (0x06) 20:51:13.496 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 2 20:51:13.497 CNTRLR [Node 012] supports CC Version (0x86) in version 2 20:51:13.498 CNTRLR » [Node 012] querying the CC version for Binary Sensor (0x30)... 20:51:13.501 SERIAL » 0x010a00130c03861330250d64 (12 bytes) 20:51:13.501 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 13 └─[VersionCCCommandClassGet] CC: Binary Sensor 20:51:13.502 SERIAL « [ACK] (0x06) 20:51:13.506 SERIAL « 0x0104011301e8 (6 bytes) 20:51:13.507 SERIAL » [ACK] (0x06) 20:51:13.507 DRIVER « [RES] [SendData] was sent: true 20:51:13.521 SERIAL « 0x010700130d000002e4 (9 bytes) 20:51:13.521 SERIAL » [ACK] (0x06) 20:51:13.521 DRIVER « [REQ] [SendData] callback id: 13 transmit status: OK 20:51:13.535 SERIAL « 0x010a0004000c048614300259 (12 bytes) 20:51:13.535 SERIAL » [ACK] (0x06) 20:51:13.536 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Binary Sensor version: 2 20:51:13.537 CNTRLR [Node 012] supports CC Binary Sensor (0x30) in version 2 20:51:13.537 CNTRLR » [Node 012] querying the CC version for Multilevel Sensor (0x31)... 20:51:13.541 SERIAL » 0x010a00130c03861331250e66 (12 bytes) 20:51:13.541 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 14 └─[VersionCCCommandClassGet] CC: Multilevel Sensor 20:51:13.542 SERIAL « [ACK] (0x06) 20:51:13.546 SERIAL « 0x0104011301e8 (6 bytes) 20:51:13.546 SERIAL » [ACK] (0x06) 20:51:13.546 DRIVER « [RES] [SendData] was sent: true 20:51:13.561 SERIAL « 0x010700130e000002e7 (9 bytes) 20:51:13.561 SERIAL » [ACK] (0x06) 20:51:13.561 DRIVER « [REQ] [SendData] callback id: 14 transmit status: OK 20:51:13.575 SERIAL « 0x010a0004000c04861431055f (12 bytes) 20:51:13.575 SERIAL » [ACK] (0x06) 20:51:13.575 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multilevel Sensor version: 5 20:51:13.576 CNTRLR [Node 012] supports CC Multilevel Sensor (0x31) in version 5 20:51:13.576 CNTRLR » [Node 012] querying the CC version for Association Group Information (0x59). .. 20:51:13.577 SERIAL » 0x010a00130c03861359250f0f (12 bytes) 20:51:13.577 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 15 └─[VersionCCCommandClassGet] CC: Association Group Information 20:51:13.579 SERIAL « [ACK] (0x06) 20:51:13.583 SERIAL « 0x0104011301e8 (6 bytes) 20:51:13.583 SERIAL » [ACK] (0x06) 20:51:13.583 DRIVER « [RES] [SendData] was sent: true 20:51:13.598 SERIAL « 0x010700130f000001e5 (9 bytes) 20:51:13.598 SERIAL » [ACK] (0x06) 20:51:13.599 DRIVER « [REQ] [SendData] callback id: 15 transmit status: OK 20:51:13.612 SERIAL « 0x010a0004000c048614590133 (12 bytes) 20:51:13.612 SERIAL » [ACK] (0x06) 20:51:13.613 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association Group Information version: 1 20:51:13.616 CNTRLR [Node 012] supports CC Association Group Information (0x59) in version 1 20:51:13.616 CNTRLR [Node 012] skipping query for Powerlevel (0x73) because max implemented vers ion is 0 20:51:13.616 CNTRLR [Node 012] skipping query for Device Reset Locally (0x5a) because max implem ented version is 1 20:51:13.616 CNTRLR [Node 012] skipping query for Multi Command (0x8f) because max implemented v ersion is 1 20:51:13.616 CNTRLR [Node 012] skipping query for Security (0x98) because max implemented versio n is 1 20:51:13.616 CNTRLR » [Node 012] querying the CC version for Firmware Update Meta Data (0x7a)... 20:51:13.620 SERIAL » 0x010a00130c0386137a251033 (12 bytes) 20:51:13.620 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[VersionCCCommandClassGet] CC: Firmware Update Meta Data 20:51:13.621 SERIAL « [ACK] (0x06) 20:51:13.625 SERIAL « 0x0104011301e8 (6 bytes) 20:51:13.625 SERIAL » [ACK] (0x06) 20:51:13.626 DRIVER « [RES] [SendData] was sent: true 20:51:13.640 SERIAL « 0x0107001310000002f9 (9 bytes) 20:51:13.641 SERIAL » [ACK] (0x06) 20:51:13.641 DRIVER « [REQ] [SendData] callback id: 16 transmit status: OK 20:51:13.654 SERIAL « 0x010a0004000c0486147a0213 (12 bytes) 20:51:13.655 SERIAL » [ACK] (0x06) 20:51:13.655 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Firmware Update Meta Data version: 2 20:51:13.657 CNTRLR [Node 012] supports CC Firmware Update Meta Data (0x7a) in version 2 20:51:13.657 CNTRLR » [Node 012] querying the CC version for Basic (0x20)... 20:51:13.660 SERIAL » 0x010a00130c03861320251168 (12 bytes) 20:51:13.660 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 17 └─[VersionCCCommandClassGet] CC: Basic 20:51:13.662 SERIAL « [ACK] (0x06) 20:51:13.666 SERIAL « 0x0104011301e8 (6 bytes) 20:51:13.666 SERIAL » [ACK] (0x06) 20:51:13.667 DRIVER « [RES] [SendData] was sent: true 20:51:13.681 SERIAL « 0x0107001311000002f8 (9 bytes) 20:51:13.681 SERIAL » [ACK] (0x06) 20:51:13.682 DRIVER « [REQ] [SendData] callback id: 17 transmit status: OK 20:51:13.695 SERIAL « 0x010a0004000c04861420014a (12 bytes) 20:51:13.695 SERIAL » [ACK] (0x06) 20:51:13.696 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Basic version: 1 20:51:13.697 CNTRLR [Node 012] supports CC Basic (0x20) in version 1 20:51:13.697 CNTRLR [Node 012] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 20:51:13.697 CNTRLR [Node 012] trying to load device config 20:51:13.705 CNTRLR [Node 012] device config loaded 20:51:13.713 CNTRLR [Node 012] WakeUpCC: doing a complete interview... 20:51:13.713 CNTRLR » [Node 012] retrieving wakeup capabilities from the device... 20:51:13.717 SERIAL » 0x010900130c028409251251 (11 bytes) 20:51:13.717 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 18 └─[WakeUpCCIntervalCapabilitiesGet] 20:51:13.718 SERIAL « [ACK] (0x06) 20:51:13.722 SERIAL « 0x0104011301e8 (6 bytes) 20:51:13.722 SERIAL » [ACK] (0x06) 20:51:13.723 DRIVER « [RES] [SendData] was sent: true 20:51:13.737 SERIAL « 0x0107001312000001f8 (9 bytes) 20:51:13.737 SERIAL » [ACK] (0x06) 20:51:13.737 DRIVER « [REQ] [SendData] callback id: 18 transmit status: OK 20:51:13.752 SERIAL « 0x01140004000c0e840a000708069780015180000708a2 (22 bytes) 20:51:13.753 CNTRLR [Node 012] [Wake Up] wakeUpInterval: metadata updated [Endpoint 0] 20:51:13.754 SERIAL » [ACK] (0x06) 20:51:13.754 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalCapabilitiesReport] default interval: 86400 seconds minimum interval: 1800 seconds maximum interval: 432000 seconds interval steps: 1800 seconds 20:51:13.756 CNTRLR « [Node 012] received wakeup capabilities: default wakeup interval: 86400 seconds minimum wakeup interval: 1800 seconds maximum wakeup interval: 432000 seconds wakeup interval steps: 1800 seconds 20:51:13.756 CNTRLR » [Node 012] retrieving wakeup interval from the device... 20:51:13.759 SERIAL » 0x010900130c02840525135c (11 bytes) 20:51:13.760 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 19 └─[WakeUpCCIntervalGet] 20:51:13.761 SERIAL « [ACK] (0x06) 20:51:13.765 SERIAL « 0x0104011301e8 (6 bytes) 20:51:13.765 SERIAL » [ACK] (0x06) 20:51:13.766 DRIVER « [RES] [SendData] was sent: true 20:51:13.780 SERIAL « 0x0107001313000002fa (9 bytes) 20:51:13.780 SERIAL » [ACK] (0x06) 20:51:13.780 DRIVER « [REQ] [SendData] callback id: 19 transmit status: OK 20:51:13.794 SERIAL « 0x010c0004000c0684060007080171 (14 bytes) 20:51:13.795 CNTRLR [Node 012] [+] [Wake Up] wakeUpInterval: 1800 [Endpoint 0] 20:51:13.796 CNTRLR [Node 012] [+] [Wake Up] controllerNodeId: 1 [Endpoint 0] 20:51:13.796 SERIAL » [ACK] (0x06) 20:51:13.797 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 1800 seconds controller node id: 1 20:51:13.798 CNTRLR « [Node 012] received wakeup configuration: wakeup interval: 1800 seconds controller node: 1 20:51:13.799 CNTRLR [Node 012] [+] [Wake Up] interviewComplete: true [Endpoint 0] [internal] 20:51:13.799 CNTRLR [Node 012] ZWavePlusCC: doing a complete interview... 20:51:13.799 CNTRLR » [Node 012] querying Z-Wave+ information... 20:51:13.805 SERIAL » 0x010900130c025e01251485 (11 bytes) 20:51:13.806 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 20 └─[ZWavePlusCCGet] 20:51:13.807 SERIAL « [ACK] (0x06) 20:51:13.811 SERIAL « 0x0104011301e8 (6 bytes) 20:51:13.811 SERIAL » [ACK] (0x06) 20:51:13.811 DRIVER « [RES] [SendData] was sent: true 20:51:13.826 SERIAL « 0x0107001314000002fd (9 bytes) 20:51:13.826 SERIAL » [ACK] (0x06) 20:51:13.827 DRIVER « [REQ] [SendData] callback id: 20 transmit status: OK 20:51:13.840 SERIAL « 0x010f0004000c095e020106000c060c06aa (17 bytes) 20:51:13.841 CNTRLR [Node 012] [+] [Z-Wave Plus Info] zwavePlusVersion: 1 [Endpoint 0] 20:51:13.842 CNTRLR [Node 012] [+] [Z-Wave Plus Info] nodeType: 0 [Endpoint 0] 20:51:13.842 CNTRLR [Node 012] [+] [Z-Wave Plus Info] roleType: 6 [Endpoint 0] 20:51:13.843 CNTRLR [Node 012] [+] [Z-Wave Plus Info] installerIcon: 3078 [Endpoint 0] 20:51:13.843 CNTRLR [Node 012] [+] [Z-Wave Plus Info] userIcon: 3078 [Endpoint 0] 20:51:13.843 SERIAL » [ACK] (0x06) 20:51:13.845 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ZWavePlusCCReport] version: 1 node type: Node role type: SleepingReportingSlave icon (mgmt.): 0x0c06 icon (user): 0x0c06 20:51:13.846 CNTRLR « [Node 012] received response for Z-Wave+ information: Z-Wave+ version: 1 role type: SleepingReportingSlave node type: Node installer icon: 0x0c06 user icon: 0x0c06 20:51:13.846 CNTRLR [Node 012] [+] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue 20:51:13.846 CNTRLR [Node 012] BatteryCC: doing a complete interview... 20:51:13.847 CNTRLR » [Node 012] querying battery status... 20:51:13.850 SERIAL » 0x010900130c028002251559 (11 bytes) 20:51:13.850 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 21 └─[BatteryCCGet] 20:51:13.852 SERIAL « [ACK] (0x06) 20:51:13.856 SERIAL « 0x0104011301e8 (6 bytes) 20:51:13.856 SERIAL » [ACK] (0x06) 20:51:13.856 DRIVER « [RES] [SendData] was sent: true 20:51:13.871 SERIAL « 0x0107001315000002fc (9 bytes) 20:51:13.871 SERIAL » [ACK] (0x06) 20:51:13.872 DRIVER « [REQ] [SendData] callback id: 21 transmit status: OK 20:51:13.885 SERIAL « 0x01090004000c038003641a (11 bytes) 20:51:13.886 CNTRLR [Node 012] [+] [Battery] level: 100 [Endpoint 0] 20:51:13.886 CNTRLR [Node 012] [+] [Battery] isLow: false [Endpoint 0] 20:51:13.887 SERIAL » [ACK] (0x06) 20:51:13.887 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 20:51:13.889 CNTRLR « [Node 012] received response for battery information: level: 100 20:51:13.889 CNTRLR [Node 012] [+] [Battery] interviewComplete: true [Endpoint 0] [internal] 20:51:13.898 CNTRLR [Node 012] ConfigurationCC: Loading configuration parameters from device confi g 20:51:13.901 CNTRLR [Node 012] [+] [Configuration] isParamInformationFromConfig: false [internal] 20:51:13.902 CNTRLR [Node 012] [Configuration] 2: metadata updated 20:51:13.903 CNTRLR [Node 012] [Configuration] 3: metadata updated 20:51:13.904 CNTRLR [Node 012] [Configuration] 4: metadata updated 20:51:13.905 CNTRLR [Node 012] [Configuration] 5: metadata updated 20:51:13.905 CNTRLR [Node 012] [Configuration] 6: metadata updated 20:51:13.906 CNTRLR [Node 012] [Configuration] 7: metadata updated 20:51:13.907 CNTRLR [Node 012] [Configuration] 8: metadata updated 20:51:13.908 CNTRLR [Node 012] [Configuration] 9: metadata updated 20:51:13.908 CNTRLR [Node 012] [Configuration] 10: metadata updated 20:51:13.909 CNTRLR [Node 012] [Configuration] 11: metadata updated 20:51:13.909 CNTRLR [Node 012] [Configuration] 12: metadata updated 20:51:13.910 CNTRLR [Node 012] [Configuration] 13: metadata updated 20:51:13.910 CNTRLR [Node 012] [Configuration] 20: metadata updated 20:51:13.911 CNTRLR [Node 012] [Configuration] 21: metadata updated 20:51:13.911 CNTRLR [Node 012] [Configuration] 22: metadata updated 20:51:13.912 CNTRLR [Node 012] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 20:51:13.912 CNTRLR » [Node 012] querying parameter #2 value... 20:51:13.916 SERIAL » 0x010a00130c037005022516ad (12 bytes) 20:51:13.916 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 22 └─[ConfigurationCCGet] parameter #: 2 20:51:13.918 SERIAL « [ACK] (0x06) 20:51:13.922 SERIAL « 0x0104011301e8 (6 bytes) 20:51:13.922 SERIAL » [ACK] (0x06) 20:51:13.923 DRIVER « [RES] [SendData] was sent: true 20:51:13.937 SERIAL « 0x0107001316000002ff (9 bytes) 20:51:13.937 SERIAL » [ACK] (0x06) 20:51:13.937 DRIVER « [REQ] [SendData] callback id: 22 transmit status: OK 20:51:13.951 SERIAL « 0x010b0004000c0570060201ff73 (13 bytes) 20:51:13.952 CNTRLR [Node 012] [+] [Configuration] 2: -1 20:51:13.952 SERIAL » [ACK] (0x06) 20:51:13.953 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: -1 20:51:13.953 CNTRLR « [Node 012] parameter #2 has value: -1 20:51:13.953 CNTRLR » [Node 012] querying parameter #3 value... 20:51:13.954 SERIAL » 0x010a00130c037005032517ad (12 bytes) 20:51:13.955 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 23 └─[ConfigurationCCGet] parameter #: 3 20:51:13.956 SERIAL « [ACK] (0x06) 20:51:13.960 SERIAL « 0x0104011301e8 (6 bytes) 20:51:13.960 SERIAL » [ACK] (0x06) 20:51:13.960 DRIVER « [RES] [SendData] was sent: true 20:51:13.975 SERIAL « 0x0107001317000002fe (9 bytes) 20:51:13.975 SERIAL » [ACK] (0x06) 20:51:13.975 DRIVER « [REQ] [SendData] callback id: 23 transmit status: OK 20:51:13.989 SERIAL « 0x010b0004000c0570060301008d (13 bytes) 20:51:13.991 CNTRLR [Node 012] [+] [Configuration] 3: 0 20:51:13.991 SERIAL » [ACK] (0x06) 20:51:13.992 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 20:51:13.993 CNTRLR « [Node 012] parameter #3 has value: 0 20:51:13.993 CNTRLR » [Node 012] querying parameter #4 value... 20:51:13.996 SERIAL » 0x010a00130c037005042518a5 (12 bytes) 20:51:13.996 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 24 └─[ConfigurationCCGet] parameter #: 4 20:51:13.998 SERIAL « [ACK] (0x06) 20:51:14.001 SERIAL « 0x0104011301e8 (6 bytes) 20:51:14.001 SERIAL » [ACK] (0x06) 20:51:14.002 DRIVER « [RES] [SendData] was sent: true 20:51:14.016 SERIAL « 0x0107001318000002f1 (9 bytes) 20:51:14.017 SERIAL » [ACK] (0x06) 20:51:14.017 DRIVER « [REQ] [SendData] callback id: 24 transmit status: OK 20:51:14.030 SERIAL « 0x010b0004000c057006040163e9 (13 bytes) 20:51:14.033 CNTRLR [Node 012] [+] [Configuration] 4: 99 20:51:14.034 SERIAL » [ACK] (0x06) 20:51:14.034 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 1 value: 99 20:51:14.035 CNTRLR « [Node 012] parameter #4 has value: 99 20:51:14.036 CNTRLR » [Node 012] querying parameter #5 value... 20:51:14.039 SERIAL » 0x010a00130c037005052519a5 (12 bytes) 20:51:14.039 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 25 └─[ConfigurationCCGet] parameter #: 5 20:51:14.040 SERIAL « [ACK] (0x06) 20:51:14.045 SERIAL « 0x0104011301e8 (6 bytes) 20:51:14.045 SERIAL » [ACK] (0x06) 20:51:14.045 DRIVER « [RES] [SendData] was sent: true 20:51:14.060 SERIAL « 0x0107001319000002f0 (9 bytes) 20:51:14.060 SERIAL » [ACK] (0x06) 20:51:14.061 DRIVER « [REQ] [SendData] callback id: 25 transmit status: OK 20:51:14.076 SERIAL « 0x010b0004000c0570060501008b (13 bytes) 20:51:14.079 CNTRLR [Node 012] [+] [Configuration] 5: 0 20:51:14.080 SERIAL » [ACK] (0x06) 20:51:14.080 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 1 value: 0 20:51:14.081 CNTRLR « [Node 012] parameter #5 has value: 0 20:51:14.082 CNTRLR » [Node 012] querying parameter #6 value... 20:51:14.087 SERIAL » 0x010a00130c03700506251aa5 (12 bytes) 20:51:14.093 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 26 └─[ConfigurationCCGet] parameter #: 6 20:51:14.098 SERIAL « [ACK] (0x06) 20:51:14.099 SERIAL « 0x0104011301e8 (6 bytes) 20:51:14.099 SERIAL » [ACK] (0x06) 20:51:14.101 DRIVER « [RES] [SendData] was sent: true 20:51:14.113 SERIAL « 0x010700131a000002f3 (9 bytes) 20:51:14.113 SERIAL » [ACK] (0x06) 20:51:14.113 DRIVER « [REQ] [SendData] callback id: 26 transmit status: OK 20:51:14.127 SERIAL « 0x010b0004000c0570060601169e (13 bytes) 20:51:14.128 CNTRLR [Node 012] [+] [Configuration] 6: 22 20:51:14.128 SERIAL » [ACK] (0x06) 20:51:14.128 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 1 value: 22 20:51:14.129 CNTRLR « [Node 012] parameter #6 has value: 22 20:51:14.129 CNTRLR » [Node 012] querying parameter #7 value... 20:51:14.131 SERIAL » 0x010a00130c03700507251ba5 (12 bytes) 20:51:14.131 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 27 └─[ConfigurationCCGet] parameter #: 7 20:51:14.132 SERIAL « [ACK] (0x06) 20:51:14.136 SERIAL « 0x0104011301e8 (6 bytes) 20:51:14.136 SERIAL » [ACK] (0x06) 20:51:14.136 DRIVER « [RES] [SendData] was sent: true 20:51:14.151 SERIAL « 0x010700131b000002f2 (9 bytes) 20:51:14.151 SERIAL » [ACK] (0x06) 20:51:14.151 DRIVER « [REQ] [SendData] callback id: 27 transmit status: OK 20:51:14.165 SERIAL « 0x010b0004000c0570060701149d (13 bytes) 20:51:14.166 CNTRLR [Node 012] [+] [Configuration] 7: 20 20:51:14.167 SERIAL » [ACK] (0x06) 20:51:14.167 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 7 value size: 1 value: 20 20:51:14.168 CNTRLR « [Node 012] parameter #7 has value: 20 20:51:14.168 CNTRLR » [Node 012] querying parameter #8 value... 20:51:14.170 SERIAL » 0x010a00130c03700508251cad (12 bytes) 20:51:14.170 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 28 └─[ConfigurationCCGet] parameter #: 8 20:51:14.171 SERIAL « [ACK] (0x06) 20:51:14.175 SERIAL « 0x0104011301e8 (6 bytes) 20:51:14.175 SERIAL » [ACK] (0x06) 20:51:14.176 DRIVER « [RES] [SendData] was sent: true 20:51:14.191 SERIAL « 0x010700131c000002f5 (9 bytes) 20:51:14.191 SERIAL » [ACK] (0x06) 20:51:14.191 DRIVER « [REQ] [SendData] callback id: 28 transmit status: OK 20:51:14.205 SERIAL « 0x010b0004000c05700608010385 (13 bytes) 20:51:14.207 CNTRLR [Node 012] [+] [Configuration] 8: 3 20:51:14.208 SERIAL » [ACK] (0x06) 20:51:14.208 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 3 20:51:14.210 CNTRLR « [Node 012] parameter #8 has value: 3 20:51:14.210 CNTRLR » [Node 012] querying parameter #9 value... 20:51:14.215 SERIAL » 0x010a00130c03700509251dad (12 bytes) 20:51:14.216 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 29 └─[ConfigurationCCGet] parameter #: 9 20:51:14.217 SERIAL « [ACK] (0x06) 20:51:14.221 SERIAL « 0x0104011301e8 (6 bytes) 20:51:14.221 SERIAL » [ACK] (0x06) 20:51:14.222 DRIVER « [RES] [SendData] was sent: true 20:51:14.236 SERIAL « 0x010700131d000002f4 (9 bytes) 20:51:14.236 SERIAL » [ACK] (0x06) 20:51:14.237 DRIVER « [REQ] [SendData] callback id: 29 transmit status: OK 20:51:14.250 SERIAL « 0x010b0004000c05700609010483 (13 bytes) 20:51:14.253 CNTRLR [Node 012] [+] [Configuration] 9: 4 20:51:14.254 SERIAL » [ACK] (0x06) 20:51:14.254 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 1 value: 4 20:51:14.255 CNTRLR « [Node 012] parameter #9 has value: 4 20:51:14.256 CNTRLR » [Node 012] querying parameter #10 value... 20:51:14.259 SERIAL » 0x010a00130c0370050a251ead (12 bytes) 20:51:14.259 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 30 └─[ConfigurationCCGet] parameter #: 10 20:51:14.263 SERIAL « [ACK] (0x06) 20:51:14.265 SERIAL « 0x0104011301e8 (6 bytes) 20:51:14.266 SERIAL » [ACK] (0x06) 20:51:14.266 DRIVER « [RES] [SendData] was sent: true 20:51:14.280 SERIAL « 0x010700131e000002f7 (9 bytes) 20:51:14.280 SERIAL » [ACK] (0x06) 20:51:14.280 DRIVER « [REQ] [SendData] callback id: 30 transmit status: OK 20:51:14.294 SERIAL « 0x010b0004000c0570060a010c88 (13 bytes) 20:51:14.296 CNTRLR [Node 012] [+] [Configuration] 10: 12 20:51:14.297 SERIAL » [ACK] (0x06) 20:51:14.298 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 12 20:51:14.299 CNTRLR « [Node 012] parameter #10 has value: 12 20:51:14.299 CNTRLR » [Node 012] querying parameter #11 value... 20:51:14.302 SERIAL » 0x010a00130c0370050b251fad (12 bytes) 20:51:14.303 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 31 └─[ConfigurationCCGet] parameter #: 11 20:51:14.305 SERIAL « [ACK] (0x06) 20:51:14.308 SERIAL « 0x0104011301e8 (6 bytes) 20:51:14.308 SERIAL » [ACK] (0x06) 20:51:14.308 DRIVER « [RES] [SendData] was sent: true 20:51:14.323 SERIAL « 0x010700131f000002f6 (9 bytes) 20:51:14.323 SERIAL » [ACK] (0x06) 20:51:14.324 DRIVER « [REQ] [SendData] callback id: 31 transmit status: OK 20:51:14.337 SERIAL « 0x010b0004000c0570060b010c89 (13 bytes) 20:51:14.341 CNTRLR [Node 012] [+] [Configuration] 11: 12 20:51:14.342 SERIAL » [ACK] (0x06) 20:51:14.343 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 11 value size: 1 value: 12 20:51:14.344 CNTRLR « [Node 012] parameter #11 has value: 12 20:51:14.344 CNTRLR » [Node 012] querying parameter #12 value... 20:51:14.350 SERIAL » 0x010a00130c0370050c252095 (12 bytes) 20:51:14.351 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 32 └─[ConfigurationCCGet] parameter #: 12 20:51:14.352 SERIAL « [ACK] (0x06) 20:51:14.356 SERIAL « 0x0104011301e8 (6 bytes) 20:51:14.356 SERIAL » [ACK] (0x06) 20:51:14.357 DRIVER « [RES] [SendData] was sent: true 20:51:14.371 SERIAL « 0x0107001320000002c9 (9 bytes) 20:51:14.371 SERIAL » [ACK] (0x06) 20:51:14.372 DRIVER « [REQ] [SendData] callback id: 32 transmit status: OK 20:51:14.385 SERIAL « 0x010b0004000c0570060c010c8e (13 bytes) 20:51:14.387 CNTRLR [Node 012] [+] [Configuration] 12: 12 20:51:14.387 SERIAL » [ACK] (0x06) 20:51:14.388 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 1 value: 12 20:51:14.388 CNTRLR « [Node 012] parameter #12 has value: 12 20:51:14.389 CNTRLR » [Node 012] querying parameter #13 value... 20:51:14.391 SERIAL » 0x010a00130c0370050d252195 (12 bytes) 20:51:14.391 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 33 └─[ConfigurationCCGet] parameter #: 13 20:51:14.392 SERIAL « [ACK] (0x06) 20:51:14.396 SERIAL « 0x0104011301e8 (6 bytes) 20:51:14.397 SERIAL » [ACK] (0x06) 20:51:14.397 DRIVER « [RES] [SendData] was sent: true 20:51:14.411 SERIAL « 0x0107001321000002c8 (9 bytes) 20:51:14.412 SERIAL » [ACK] (0x06) 20:51:14.412 DRIVER « [REQ] [SendData] callback id: 33 transmit status: OK 20:51:14.425 SERIAL « 0x010b0004000c0570060d010c8f (13 bytes) 20:51:14.428 CNTRLR [Node 012] [+] [Configuration] 13: 12 20:51:14.428 SERIAL » [ACK] (0x06) 20:51:14.429 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 12 20:51:14.430 CNTRLR « [Node 012] parameter #13 has value: 12 20:51:14.430 CNTRLR » [Node 012] querying parameter #20 value... 20:51:14.434 SERIAL » 0x010a00130c0370051425228f (12 bytes) 20:51:14.434 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 34 └─[ConfigurationCCGet] parameter #: 20 20:51:14.436 SERIAL « [ACK] (0x06) 20:51:14.439 SERIAL « 0x0104011301e8 (6 bytes) 20:51:14.439 SERIAL » [ACK] (0x06) 20:51:14.440 DRIVER « [RES] [SendData] was sent: true 20:51:14.454 SERIAL « 0x0107001322000002cb (9 bytes) 20:51:14.455 SERIAL » [ACK] (0x06) 20:51:14.455 DRIVER « [REQ] [SendData] callback id: 34 transmit status: OK 20:51:14.468 SERIAL « 0x010b0004000c05700614011e84 (13 bytes) 20:51:14.470 CNTRLR [Node 012] [+] [Configuration] 20: 30 20:51:14.471 SERIAL » [ACK] (0x06) 20:51:14.472 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 30 20:51:14.473 CNTRLR « [Node 012] parameter #20 has value: 30 20:51:14.473 CNTRLR » [Node 012] querying parameter #21 value... 20:51:14.479 SERIAL » 0x010a00130c0370051525238f (12 bytes) 20:51:14.480 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 35 └─[ConfigurationCCGet] parameter #: 21 20:51:14.483 SERIAL « [ACK] (0x06) 20:51:14.486 SERIAL « 0x0104011301e8 (6 bytes) 20:51:14.486 SERIAL » [ACK] (0x06) 20:51:14.487 DRIVER « [RES] [SendData] was sent: true 20:51:14.501 SERIAL « 0x0107001323000002ca (9 bytes) 20:51:14.501 SERIAL » [ACK] (0x06) 20:51:14.502 DRIVER « [REQ] [SendData] callback id: 35 transmit status: OK 20:51:14.515 SERIAL « 0x010b0004000c0570061501019a (13 bytes) 20:51:14.517 CNTRLR [Node 012] [+] [Configuration] 21: 1 20:51:14.518 SERIAL » [ACK] (0x06) 20:51:14.519 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 21 value size: 1 value: 1 20:51:14.520 CNTRLR « [Node 012] parameter #21 has value: 1 20:51:14.520 CNTRLR » [Node 012] querying parameter #22 value... 20:51:14.523 SERIAL » 0x010a00130c0370051625248b (12 bytes) 20:51:14.524 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 36 └─[ConfigurationCCGet] parameter #: 22 20:51:14.527 SERIAL « [ACK] (0x06) 20:51:14.530 SERIAL « 0x0104011301e8 (6 bytes) 20:51:14.530 SERIAL » [ACK] (0x06) 20:51:14.531 DRIVER « [RES] [SendData] was sent: true 20:51:14.545 SERIAL « 0x0107001324000002cd (9 bytes) 20:51:14.545 SERIAL » [ACK] (0x06) 20:51:14.546 DRIVER « [REQ] [SendData] callback id: 36 transmit status: OK 20:51:14.559 SERIAL « 0x010b0004000c05700616010098 (13 bytes) 20:51:14.561 CNTRLR [Node 012] [+] [Configuration] 22: 0 20:51:14.562 SERIAL » [ACK] (0x06) 20:51:14.563 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 1 value: 0 20:51:14.564 CNTRLR « [Node 012] parameter #22 has value: 0 20:51:14.565 CNTRLR [Node 012] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 20:51:14.573 CNTRLR [Node 012] BinarySensorCC: doing a complete interview... 20:51:14.573 CNTRLR » [Node 012] querying supported sensor types... 20:51:14.577 SERIAL » 0x010900130c0230012525da (11 bytes) 20:51:14.578 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 37 └─[BinarySensorCCSupportedGet] 20:51:14.579 SERIAL « [ACK] (0x06) 20:51:14.583 SERIAL « 0x0104011301e8 (6 bytes) 20:51:14.583 SERIAL » [ACK] (0x06) 20:51:14.583 DRIVER « [RES] [SendData] was sent: true 20:51:14.598 SERIAL « 0x0107001325000001cf (9 bytes) 20:51:14.598 SERIAL » [ACK] (0x06) 20:51:14.598 DRIVER « [REQ] [SendData] callback id: 37 transmit status: OK 20:51:14.612 SERIAL « 0x010a0004000c0430040005c8 (12 bytes) 20:51:14.612 CNTRLR [Node 012] [+] [Binary Sensor] supportedSensorTypes: 9 [Endpoint 0] [internal] ,11 20:51:14.612 SERIAL » [ACK] (0x06) 20:51:14.613 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[BinarySensorCCSupportedReport] supported types: Aux, Tilt 20:51:14.614 CNTRLR « [Node 012] received supported sensor types: · Aux · Tilt 20:51:14.614 CNTRLR » [Node 012] querying current value for Aux... 20:51:14.616 SERIAL » 0x010a00130c033002092526d1 (12 bytes) 20:51:14.616 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 38 └─[BinarySensorCCGet] type: Aux 20:51:14.617 SERIAL « [ACK] (0x06) 20:51:14.621 SERIAL « 0x0104011301e8 (6 bytes) 20:51:14.621 SERIAL » [ACK] (0x06) 20:51:14.622 DRIVER « [RES] [SendData] was sent: true 20:51:14.636 SERIAL « 0x0107001326000002cf (9 bytes) 20:51:14.636 SERIAL » [ACK] (0x06) 20:51:14.637 DRIVER « [REQ] [SendData] callback id: 38 transmit status: OK 20:51:16.241 CNTRLR [Node 012] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 20:51:16.743 SERIAL » 0x010a00130c033002092526d1 (12 bytes) 20:51:16.744 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 38 └─[BinarySensorCCGet] type: Aux 20:51:16.745 SERIAL « [ACK] (0x06) 20:51:16.749 SERIAL « 0x0104011301e8 (6 bytes) 20:51:16.750 SERIAL » [ACK] (0x06) 20:51:16.750 DRIVER « [RES] [SendData] was sent: true 20:51:16.764 SERIAL « 0x0107001326000002cf (9 bytes) 20:51:16.765 SERIAL » [ACK] (0x06) 20:51:16.765 DRIVER « [REQ] [SendData] callback id: 38 transmit status: OK 20:51:17.822 SERIAL « 0x010c0004001c06310504220246bb (14 bytes) 20:51:17.823 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:51:17.823 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 68.6 => 58.2 [Endpoint 0] 20:51:17.824 SERIAL » [ACK] (0x06) 20:51:17.825 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 58.2 20:51:18.368 CNTRLR [Node 012] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 20:51:18.871 SERIAL » 0x010a00130c033002092526d1 (12 bytes) 20:51:18.871 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 38 └─[BinarySensorCCGet] type: Aux 20:51:18.873 SERIAL « [ACK] (0x06) 20:51:18.877 SERIAL « 0x0104011301e8 (6 bytes) 20:51:18.877 SERIAL » [ACK] (0x06) 20:51:18.878 DRIVER « [RES] [SendData] was sent: true 20:51:18.892 SERIAL « 0x0107001326000002cf (9 bytes) 20:51:18.892 SERIAL » [ACK] (0x06) 20:51:18.892 DRIVER « [REQ] [SendData] callback id: 38 transmit status: OK 20:51:20.496 CNTRLR [Node 012] Current value query for Aux timed out - skipping because it is not critical... 20:51:20.497 CNTRLR » [Node 012] querying current value for Tilt... 20:51:20.500 SERIAL » 0x010a00130c0330020b2527d2 (12 bytes) 20:51:20.500 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[BinarySensorCCGet] type: Tilt 20:51:20.502 SERIAL « [ACK] (0x06) 20:51:20.506 SERIAL « 0x0104011301e8 (6 bytes) 20:51:20.506 SERIAL » [ACK] (0x06) 20:51:20.506 DRIVER « [RES] [SendData] was sent: true 20:51:20.521 SERIAL « 0x0107001327000002ce (9 bytes) 20:51:20.521 SERIAL » [ACK] (0x06) 20:51:20.521 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 20:51:22.124 CNTRLR [Node 012] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 20:51:22.626 SERIAL » 0x010a00130c0330020b2527d2 (12 bytes) 20:51:22.627 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[BinarySensorCCGet] type: Tilt 20:51:22.629 SERIAL « [ACK] (0x06) 20:51:22.633 SERIAL « 0x0104011301e8 (6 bytes) 20:51:22.633 SERIAL » [ACK] (0x06) 20:51:22.633 DRIVER « [RES] [SendData] was sent: true 20:51:22.647 SERIAL « 0x0107001327000001cd (9 bytes) 20:51:22.648 SERIAL » [ACK] (0x06) 20:51:22.648 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 20:51:24.251 CNTRLR [Node 012] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 20:51:24.616 DRIVER The awake timeout for node 12 has elapsed. Assuming it is asleep. 20:51:24.616 CNTRLR [Node 012] The node is now asleep. 20:51:32.234 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:51:32.235 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:51:32.236 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:51:32.236 SERIAL » [ACK] (0x06) 20:51:32.237 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:51:42.823 SERIAL « 0x01100004001c0a32022144000013db000060 (18 bytes) 20:51:42.824 CNTRLR [Node 028] [~] [Meter] value[65537]: 50.81 => 50.83 [Endpoint 0] 20:51:42.824 CNTRLR [Node 028] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 20:51:42.825 SERIAL » [ACK] (0x06) 20:51:42.827 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 50.83 time delta: 0 seconds 20:52:16.895 SERIAL « 0x010c0004001a06310504220835c4 (14 bytes) 20:52:16.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:52:16.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 247.9 => 210.1 [Endpoint 0] 20:52:16.896 SERIAL » [ACK] (0x06) 20:52:16.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 210.1 20:52:32.895 SERIAL « 0x010c0004001a0631050422099b6b (14 bytes) 20:52:32.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:52:32.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 210.1 => 245.9 [Endpoint 0] 20:52:32.896 SERIAL » [ACK] (0x06) 20:52:32.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 245.9 20:52:40.822 SERIAL « 0x010c0004001c063105042202a558 (14 bytes) 20:52:40.822 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:52:40.823 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 58.2 => 67.7 [Endpoint 0] 20:52:40.823 SERIAL » [ACK] (0x06) 20:52:40.824 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 67.7 20:52:46.821 SERIAL « 0x010c0004001c0631050422023fc2 (14 bytes) 20:52:46.822 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:52:46.822 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 67.7 => 57.5 [Endpoint 0] 20:52:46.822 SERIAL » [ACK] (0x06) 20:52:46.823 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 57.5 20:52:51.821 SERIAL « 0x010c0004001c063105042202c33e (14 bytes) 20:52:51.822 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:52:51.823 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 57.5 => 70.7 [Endpoint 0] 20:52:51.823 SERIAL » [ACK] (0x06) 20:52:51.824 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 70.7 20:52:54.821 SERIAL « 0x010c0004001c06310504220248b5 (14 bytes) 20:52:54.822 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:52:54.823 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 70.7 => 58.4 [Endpoint 0] 20:52:54.823 SERIAL » [ACK] (0x06) 20:52:54.825 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 58.4 20:52:54.895 SERIAL « 0x010c0004001a06310504220746b8 (14 bytes) 20:52:54.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:52:54.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 245.9 => 186.2 [Endpoint 0] 20:52:54.896 SERIAL » [ACK] (0x06) 20:52:54.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 186.2 20:52:57.895 SERIAL « 0x010c0004001a0631050422089d6c (14 bytes) 20:52:57.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:52:57.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 186.2 => 220.5 [Endpoint 0] 20:52:57.896 SERIAL » [ACK] (0x06) 20:52:57.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 220.5 20:53:08.555 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:53:08.556 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:53:08.560 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:53:08.560 SERIAL » [ACK] (0x06) 20:53:08.560 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:53:57.821 SERIAL « 0x010c0004001c063105042201ed13 (14 bytes) 20:53:57.822 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:53:57.822 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 58.4 => 49.3 [Endpoint 0] 20:53:57.823 SERIAL » [ACK] (0x06) 20:53:57.824 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 49.3 20:54:13.820 SERIAL « 0x010c0004001c06310504220243be (14 bytes) 20:54:13.821 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:54:13.822 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 49.3 => 57.9 [Endpoint 0] 20:54:13.822 SERIAL » [ACK] (0x06) 20:54:13.823 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 57.9 20:54:15.821 SERIAL « 0x010c0004001c063105042202a15c (14 bytes) 20:54:15.821 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:54:15.822 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 57.9 => 67.3 [Endpoint 0] 20:54:15.822 SERIAL » [ACK] (0x06) 20:54:15.823 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 67.3 20:54:20.047 SERIAL « 0x0110000400060a32022134000000000000c2 (18 bytes) 20:54:20.048 CNTRLR [Node 006] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:54:20.049 CNTRLR [Node 006] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:54:20.049 SERIAL » [ACK] (0x06) 20:54:20.050 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:54:36.894 SERIAL « 0x010c0004001a0631050422106d84 (14 bytes) 20:54:36.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:54:36.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 220.5 => 420.5 [Endpoint 0] 20:54:36.896 SERIAL » [ACK] (0x06) 20:54:36.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 420.5 20:54:37.895 SERIAL « 0x010c0004001a06310504220aa754 (14 bytes) 20:54:37.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:54:37.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 420.5 => 272.7 [Endpoint 0] 20:54:37.896 SERIAL » [ACK] (0x06) 20:54:37.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 272.7 20:54:38.895 SERIAL « 0x010c0004001a06310504220859a8 (14 bytes) 20:54:38.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:54:38.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 272.7 => 213.7 [Endpoint 0] 20:54:38.896 SERIAL » [ACK] (0x06) 20:54:38.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 213.7 20:54:44.877 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:54:44.877 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:54:44.878 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:54:44.878 SERIAL » [ACK] (0x06) 20:54:44.880 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:54:44.894 SERIAL « 0x010c0004001a0631050422099c6c (14 bytes) 20:54:44.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:54:44.895 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 213.7 => 246 [Endpoint 0] 20:54:44.896 SERIAL » [ACK] (0x06) 20:54:44.896 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 246 20:54:50.820 SERIAL « 0x010c0004001c06310504220235c8 (14 bytes) 20:54:50.822 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:54:50.823 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 67.3 => 56.5 [Endpoint 0] 20:54:50.823 SERIAL » [ACK] (0x06) 20:54:50.824 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 56.5 20:54:52.820 SERIAL « 0x010c0004001c0631050422029e63 (14 bytes) 20:54:52.821 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:54:52.822 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 56.5 => 67 [Endpoint 0] 20:54:52.822 SERIAL » [ACK] (0x06) 20:54:52.823 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 67 20:54:56.820 SERIAL « 0x010c0004001c06310504220237ca (14 bytes) 20:54:56.820 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:54:56.821 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 67 => 56.7 [Endpoint 0] 20:54:56.821 SERIAL » [ACK] (0x06) 20:54:56.822 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 56.7 20:55:16.884 SERIAL « 0x0109000400110380035a39 (11 bytes) 20:55:16.885 CNTRLR [Node 017] [~] [Battery] level: 90 => 90 [Endpoint 0] 20:55:16.886 CNTRLR [Node 017] [~] [Battery] isLow: false => false [Endpoint 0] 20:55:16.886 SERIAL » [ACK] (0x06) 20:55:16.887 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 90 is low: false 20:55:16.942 SERIAL « 0x010c000400110643030142076c88 (14 bytes) 20:55:16.943 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpoint[1]: 19 => 19 [Endpoint 0] 20:55:16.944 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 20:55:16.944 SERIAL » [ACK] (0x06) 20:55:16.945 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 20:55:16.997 SERIAL « 0x010a00040011044608007fd5 (12 bytes) 20:55:16.998 CNTRLR [Node 017] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 20:55:16.999 CNTRLR [Node 017] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 20:55:16.999 SERIAL » [ACK] (0x06) 20:55:17.000 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ClimateControlScheduleCCOverrideReport] override type: None override state: Unused 20:55:17.051 SERIAL « 0x01080004001102840763 (10 bytes) 20:55:17.052 SERIAL » [ACK] (0x06) 20:55:17.052 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 20:55:17.054 CNTRLR « [Node 017] received wakeup notification 20:55:17.054 CNTRLR [Node 017] The node is now awake. 20:55:17.055 CNTRLR [Node 017] expects some queries after wake up, so it shall receive 20:55:17.055 CNTRLR [Node 017] compat query "Battery"::get() 20:55:17.063 SERIAL » 0x0109001311028002252879 (11 bytes) 20:55:17.063 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 40 └─[BatteryCCGet] 20:55:17.065 SERIAL « [ACK] (0x06) 20:55:17.069 SERIAL « 0x0104011301e8 (6 bytes) 20:55:17.069 SERIAL » [ACK] (0x06) 20:55:17.070 DRIVER « [RES] [SendData] was sent: true 20:55:17.093 SERIAL « 0x0107001328000003c0 (9 bytes) 20:55:17.094 SERIAL » [ACK] (0x06) 20:55:17.094 DRIVER « [REQ] [SendData] callback id: 40 transmit status: OK 20:55:17.102 SERIAL « 0x0109000400110380035a39 (11 bytes) 20:55:17.103 CNTRLR [Node 017] [~] [Battery] level: 90 => 90 [Endpoint 0] 20:55:17.104 CNTRLR [Node 017] [~] [Battery] isLow: false => false [Endpoint 0] 20:55:17.104 SERIAL » [ACK] (0x06) 20:55:17.105 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 90 is low: false 20:55:17.108 CNTRLR [Node 017] API call successful 20:55:17.108 CNTRLR [Node 017] compat query "Thermostat Setpoint"::get(1) 20:55:17.112 SERIAL » 0x010a001311034302012529b8 (12 bytes) 20:55:17.113 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 41 └─[ThermostatSetpointCCGet] setpoint type: Heating 20:55:17.114 SERIAL « [ACK] (0x06) 20:55:17.118 SERIAL « 0x0104011301e8 (6 bytes) 20:55:17.118 SERIAL » [ACK] (0x06) 20:55:17.119 DRIVER « [RES] [SendData] was sent: true 20:55:17.134 SERIAL « 0x0107001329000002c0 (9 bytes) 20:55:17.135 SERIAL » [ACK] (0x06) 20:55:17.135 DRIVER « [REQ] [SendData] callback id: 41 transmit status: OK 20:55:17.143 SERIAL « 0x010c000400110643030142076c88 (14 bytes) 20:55:17.144 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpoint[1]: 19 => 19 [Endpoint 0] 20:55:17.145 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 20:55:17.145 SERIAL » [ACK] (0x06) 20:55:17.146 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 20:55:17.148 CNTRLR [Node 017] API call successful 20:55:17.217 SERIAL « 0x0110000400120a32022134000000010000d7 (18 bytes) 20:55:17.218 CNTRLR [Node 018] [~] [Meter] value[66049]: 0.1 => 0.1 [Endpoint 0] 20:55:17.218 CNTRLR [Node 018] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:55:17.219 SERIAL » [ACK] (0x06) 20:55:17.220 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0.1 time delta: 0 seconds 20:55:18.147 CNTRLR » [Node 017] Sending node back to sleep... 20:55:18.152 SERIAL » 0x0109001311028408252a75 (11 bytes) 20:55:18.152 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 42 └─[WakeUpCCNoMoreInformation] 20:55:18.153 SERIAL « [ACK] (0x06) 20:55:18.157 SERIAL « 0x0104011301e8 (6 bytes) 20:55:18.157 SERIAL » [ACK] (0x06) 20:55:18.158 DRIVER « [RES] [SendData] was sent: true 20:55:18.173 SERIAL « 0x010700132a000002c3 (9 bytes) 20:55:18.173 SERIAL » [ACK] (0x06) 20:55:18.174 DRIVER « [REQ] [SendData] callback id: 42 transmit status: OK 20:55:18.176 CNTRLR [Node 017] The node is now asleep. 20:55:18.176 CNTRLR [Node 017] Node asleep 20:55:24.820 SERIAL « 0x010c0004001c063105042202fb06 (14 bytes) 20:55:24.821 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:55:24.821 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 56.7 => 76.3 [Endpoint 0] 20:55:24.822 SERIAL » [ACK] (0x06) 20:55:24.823 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 76.3 20:55:42.819 SERIAL « 0x010c0004001c063105042202817c (14 bytes) 20:55:42.820 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:55:42.821 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 76.3 => 64.1 [Endpoint 0] 20:55:42.821 SERIAL » [ACK] (0x06) 20:55:42.822 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 64.1 20:55:45.157 SERIAL « 0x0110000400030a3202214400000cfb000040 (18 bytes) 20:55:45.158 CNTRLR [Node 003] [~] [Meter] value[65537]: 33.23 => 33.23 [Endpoint 0] 20:55:45.159 CNTRLR [Node 003] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 20:55:45.159 SERIAL » [ACK] (0x06) 20:55:45.160 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 33.23 time delta: 0 seconds 20:56:04.819 SERIAL « 0x010c0004001c0631050422021fe2 (14 bytes) 20:56:04.820 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:56:04.821 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 64.1 => 54.3 [Endpoint 0] 20:56:04.821 SERIAL » [ACK] (0x06) 20:56:04.822 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 54.3 20:56:15.819 SERIAL « 0x010c0004001c063105042202bb46 (14 bytes) 20:56:15.820 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:56:15.821 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 54.3 => 69.9 [Endpoint 0] 20:56:15.821 SERIAL » [ACK] (0x06) 20:56:15.822 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 69.9 20:56:18.819 SERIAL « 0x010c0004001c06310504220250ad (14 bytes) 20:56:18.820 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:56:18.820 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 69.9 => 59.2 [Endpoint 0] 20:56:18.821 SERIAL » [ACK] (0x06) 20:56:18.821 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 59.2 20:56:21.198 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:56:21.199 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:56:21.199 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:56:21.200 SERIAL » [ACK] (0x06) 20:56:21.201 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:56:22.819 SERIAL « 0x010c0004001c06310504220307fb (14 bytes) 20:56:22.820 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:56:22.820 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 59.2 => 77.5 [Endpoint 0] 20:56:22.821 SERIAL » [ACK] (0x06) 20:56:22.822 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 77.5 20:57:05.819 SERIAL « 0x010c0004001c06310504220259a4 (14 bytes) 20:57:05.820 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:57:05.820 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 77.5 => 60.1 [Endpoint 0] 20:57:05.821 SERIAL » [ACK] (0x06) 20:57:05.822 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 60.1 20:57:15.818 SERIAL « 0x010c0004001c063105042201fe00 (14 bytes) 20:57:15.819 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:57:15.820 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 60.1 => 51 [Endpoint 0] 20:57:15.820 SERIAL » [ACK] (0x06) 20:57:15.821 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 51 20:57:21.818 SERIAL « 0x010c0004001c063105042202817c (14 bytes) 20:57:21.819 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:57:21.820 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 51 => 64.1 [Endpoint 0] 20:57:21.820 SERIAL » [ACK] (0x06) 20:57:21.821 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 64.1 20:57:30.818 SERIAL « 0x010c0004001c06310504220213ee (14 bytes) 20:57:30.819 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:57:30.820 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 64.1 => 53.1 [Endpoint 0] 20:57:30.820 SERIAL » [ACK] (0x06) 20:57:30.821 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 53.1 20:57:37.818 SERIAL « 0x010c0004001c063105042202966b (14 bytes) 20:57:37.819 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:57:37.820 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 53.1 => 66.2 [Endpoint 0] 20:57:37.820 SERIAL » [ACK] (0x06) 20:57:37.821 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 66.2 20:57:39.818 SERIAL « 0x010c0004001c06310504220309f5 (14 bytes) 20:57:39.819 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:57:39.820 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 66.2 => 77.7 [Endpoint 0] 20:57:39.820 SERIAL » [ACK] (0x06) 20:57:39.821 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 77.7 20:57:57.519 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:57:57.520 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:57:57.521 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:57:57.523 SERIAL » [ACK] (0x06) 20:57:57.523 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:58:07.818 SERIAL « 0x010c0004001c0631050422029469 (14 bytes) 20:58:07.819 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:58:07.819 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 77.7 => 66 [Endpoint 0] 20:58:07.820 SERIAL » [ACK] (0x06) 20:58:07.821 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 66 20:58:11.818 SERIAL « 0x010c0004001c063105042201fd03 (14 bytes) 20:58:11.818 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:58:11.819 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 66 => 50.9 [Endpoint 0] 20:58:11.820 SERIAL » [ACK] (0x06) 20:58:11.820 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 50.9 20:58:36.817 SERIAL « 0x010c0004001c063105042202827f (14 bytes) 20:58:36.818 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:58:36.819 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 50.9 => 64.2 [Endpoint 0] 20:58:36.819 SERIAL » [ACK] (0x06) 20:58:36.820 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 64.2 20:58:38.817 SERIAL « 0x0114000400120e32022144000002b30580000002b323 (22 bytes) 20:58:38.818 CNTRLR [Node 018] [~] [Meter] value[65537]: 6.91 => 6.91 [Endpoint 0] 20:58:38.819 CNTRLR [Node 018] [~] [Meter] previousValue[65537]: 6.91 => 6.91 [Endpoint 0] 20:58:38.820 CNTRLR [Node 018] [~] [Meter] deltaTime[65537]: 2192 => 1408 [Endpoint 0] 20:58:38.820 SERIAL » [ACK] (0x06) 20:58:38.821 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 6.91 time delta: 1408 seconds prev. value: 6.91 20:58:39.817 SERIAL « 0x010c0004001c06310504220318e4 (14 bytes) 20:58:39.818 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:58:39.818 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 64.2 => 79.2 [Endpoint 0] 20:58:39.819 SERIAL » [ACK] (0x06) 20:58:39.820 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 79.2 20:59:04.817 SERIAL « 0x010c0004001c063105042202817c (14 bytes) 20:59:04.818 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:59:04.819 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 79.2 => 64.1 [Endpoint 0] 20:59:04.819 SERIAL » [ACK] (0x06) 20:59:04.820 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 64.1 20:59:14.895 SERIAL « 0x010c0004001a0631050422069768 (14 bytes) 20:59:14.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:59:14.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 246 => 168.7 [Endpoint 0] 20:59:14.896 SERIAL » [ACK] (0x06) 20:59:14.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 168.7 20:59:18.895 SERIAL « 0x010c0004001a063105042208ab5a (14 bytes) 20:59:18.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:59:18.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 168.7 => 221.9 [Endpoint 0] 20:59:18.896 SERIAL » [ACK] (0x06) 20:59:18.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 221.9 20:59:21.817 SERIAL « 0x010c0004001c063105042202e31e (14 bytes) 20:59:21.818 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:59:21.819 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 64.1 => 73.9 [Endpoint 0] 20:59:21.819 SERIAL » [ACK] (0x06) 20:59:21.820 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 73.9 20:59:24.817 SERIAL « 0x010c0004001c0631050422038f73 (14 bytes) 20:59:24.818 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:59:24.818 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 73.9 => 91.1 [Endpoint 0] 20:59:24.819 SERIAL » [ACK] (0x06) 20:59:24.820 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 91.1 20:59:25.817 SERIAL « 0x010c0004001c063105042202ef12 (14 bytes) 20:59:25.818 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 20:59:25.818 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 91.1 => 75.1 [Endpoint 0] 20:59:25.819 SERIAL » [ACK] (0x06) 20:59:25.820 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 75.1 20:59:33.841 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 20:59:33.842 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:59:33.842 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:59:33.843 SERIAL » [ACK] (0x06) 20:59:33.844 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 20:59:43.247 SERIAL « 0x0110000400060a32022134000000000000c2 (18 bytes) 20:59:43.248 CNTRLR [Node 006] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 20:59:43.249 CNTRLR [Node 006] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 20:59:43.249 SERIAL » [ACK] (0x06) 20:59:43.250 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 21:00:00.024 SERIAL » 0x010a00131203250100252bdd (12 bytes) 21:00:00.024 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 43 └─[BinarySwitchCCSet] target value: false 21:00:00.025 SERIAL « [ACK] (0x06) 21:00:00.029 SERIAL « 0x0104011301e8 (6 bytes) 21:00:00.029 SERIAL » [ACK] (0x06) 21:00:00.029 DRIVER « [RES] [SendData] was sent: true 21:00:00.044 SERIAL « 0x010700132b000002c2 (9 bytes) 21:00:00.045 SERIAL » [ACK] (0x06) 21:00:00.045 DRIVER « [REQ] [SendData] callback id: 43 transmit status: OK 21:00:00.049 SERIAL » 0x0109001312022502252cdb (11 bytes) 21:00:00.049 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 44 └─[BinarySwitchCCGet] 21:00:00.050 SERIAL « [ACK] (0x06) 21:00:00.054 SERIAL « 0x0104011301e8 (6 bytes) 21:00:00.054 SERIAL » [ACK] (0x06) 21:00:00.055 DRIVER « [RES] [SendData] was sent: true 21:00:00.069 SERIAL « 0x010700132c000002c5 (9 bytes) 21:00:00.070 SERIAL » [ACK] (0x06) 21:00:00.070 DRIVER « [REQ] [SendData] callback id: 44 transmit status: OK 21:00:00.079 SERIAL « 0x01090004001203250300c5 (11 bytes) 21:00:00.080 CNTRLR [Node 018] [~] [Binary Switch] currentValue: true => false [Endpoint 0] 21:00:00.081 SERIAL » [ACK] (0x06) 21:00:00.082 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 21:00:09.816 SERIAL « 0x010c0004001c063105042202679a (14 bytes) 21:00:09.817 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:00:09.818 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 75.1 => 61.5 [Endpoint 0] 21:00:09.818 SERIAL » [ACK] (0x06) 21:00:09.819 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 61.5 21:00:11.702 SERIAL « 0x0109000400110380035a39 (11 bytes) 21:00:11.703 CNTRLR [Node 017] [~] [Battery] level: 90 => 90 [Endpoint 0] 21:00:11.704 CNTRLR [Node 017] [~] [Battery] isLow: false => false [Endpoint 0] 21:00:11.704 SERIAL » [ACK] (0x06) 21:00:11.705 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 90 is low: false 21:00:11.760 SERIAL « 0x010c000400110643030142076c88 (14 bytes) 21:00:11.761 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpoint[1]: 19 => 19 [Endpoint 0] 21:00:11.762 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 21:00:11.762 SERIAL » [ACK] (0x06) 21:00:11.763 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 21:00:11.815 SERIAL « 0x010a00040011044608007fd5 (12 bytes) 21:00:11.816 CNTRLR [Node 017] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 21:00:11.817 CNTRLR [Node 017] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 21:00:11.817 SERIAL » [ACK] (0x06) 21:00:11.818 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ClimateControlScheduleCCOverrideReport] override type: None override state: Unused 21:00:11.870 SERIAL « 0x01080004001102840763 (10 bytes) 21:00:11.870 SERIAL » [ACK] (0x06) 21:00:11.871 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 21:00:11.872 CNTRLR « [Node 017] received wakeup notification 21:00:11.872 CNTRLR [Node 017] The node is now awake. 21:00:11.873 CNTRLR [Node 017] expects some queries after wake up, so it shall receive 21:00:11.873 CNTRLR [Node 017] compat query "Battery"::get() 21:00:11.878 SERIAL » 0x0109001311028002252d7c (11 bytes) 21:00:11.878 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 45 └─[BatteryCCGet] 21:00:11.879 SERIAL « [ACK] (0x06) 21:00:11.883 SERIAL « 0x0104011301e8 (6 bytes) 21:00:11.883 SERIAL » [ACK] (0x06) 21:00:11.884 DRIVER « [RES] [SendData] was sent: true 21:00:11.912 SERIAL « 0x010700132d000003c5 (9 bytes) 21:00:11.912 SERIAL » [ACK] (0x06) 21:00:11.913 DRIVER « [REQ] [SendData] callback id: 45 transmit status: OK 21:00:11.921 SERIAL « 0x0109000400110380035a39 (11 bytes) 21:00:11.922 CNTRLR [Node 017] [~] [Battery] level: 90 => 90 [Endpoint 0] 21:00:11.922 CNTRLR [Node 017] [~] [Battery] isLow: false => false [Endpoint 0] 21:00:11.923 SERIAL » [ACK] (0x06) 21:00:11.924 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 90 is low: false 21:00:11.925 CNTRLR [Node 017] API call successful 21:00:11.925 CNTRLR [Node 017] compat query "Thermostat Setpoint"::get(1) 21:00:11.929 SERIAL » 0x010a00131103430201252ebf (12 bytes) 21:00:11.929 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 46 └─[ThermostatSetpointCCGet] setpoint type: Heating 21:00:11.933 SERIAL « [ACK] (0x06) 21:00:11.935 SERIAL « 0x0104011301e8 (6 bytes) 21:00:11.935 SERIAL » [ACK] (0x06) 21:00:11.936 DRIVER « [RES] [SendData] was sent: true 21:00:11.951 SERIAL « 0x010700132e000002c7 (9 bytes) 21:00:11.951 SERIAL » [ACK] (0x06) 21:00:11.952 DRIVER « [REQ] [SendData] callback id: 46 transmit status: OK 21:00:11.960 SERIAL « 0x010c000400110643030142076c88 (14 bytes) 21:00:11.961 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpoint[1]: 19 => 19 [Endpoint 0] 21:00:11.962 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 21:00:11.962 SERIAL » [ACK] (0x06) 21:00:11.963 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 21:00:11.964 CNTRLR [Node 017] API call successful 21:00:12.816 SERIAL « 0x010c0004001c063105042201ff01 (14 bytes) 21:00:12.817 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:00:12.818 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 61.5 => 51.1 [Endpoint 0] 21:00:12.818 SERIAL » [ACK] (0x06) 21:00:12.819 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 51.1 21:00:12.964 CNTRLR » [Node 017] Sending node back to sleep... 21:00:12.970 SERIAL » 0x0109001311028408252f70 (11 bytes) 21:00:12.970 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 47 └─[WakeUpCCNoMoreInformation] 21:00:12.971 SERIAL « [ACK] (0x06) 21:00:12.975 SERIAL « 0x0104011301e8 (6 bytes) 21:00:12.975 SERIAL » [ACK] (0x06) 21:00:12.976 DRIVER « [RES] [SendData] was sent: true 21:00:12.991 SERIAL « 0x010700132f000002c6 (9 bytes) 21:00:12.991 SERIAL » [ACK] (0x06) 21:00:12.992 DRIVER « [REQ] [SendData] callback id: 47 transmit status: OK 21:00:12.994 CNTRLR [Node 017] The node is now asleep. 21:00:12.995 CNTRLR [Node 017] Node asleep 21:00:40.417 SERIAL « 0x0110000400120a32022134000000000000d6 (18 bytes) 21:00:40.418 CNTRLR [Node 018] [~] [Meter] value[66049]: 0.1 => 0 [Endpoint 0] 21:00:40.419 CNTRLR [Node 018] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 21:00:40.419 SERIAL » [ACK] (0x06) 21:00:40.420 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 21:01:03.816 SERIAL « 0x010c0004001c06310504220257aa (14 bytes) 21:01:03.817 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:01:03.817 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 51.1 => 59.9 [Endpoint 0] 21:01:03.819 SERIAL » [ACK] (0x06) 21:01:03.819 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 59.9 21:01:10.162 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 21:01:10.163 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 21:01:10.164 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 21:01:10.164 SERIAL » [ACK] (0x06) 21:01:10.165 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 21:01:11.816 SERIAL « 0x010c0004001c063105042202fe03 (14 bytes) 21:01:11.816 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:01:11.817 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 59.9 => 76.6 [Endpoint 0] 21:01:11.817 SERIAL » [ACK] (0x06) 21:01:11.818 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 76.6 21:01:31.895 SERIAL « 0x01100004001a0a32022144000035ed000076 (18 bytes) 21:01:31.896 CNTRLR [Node 026] [~] [Meter] value[65537]: 137.95 => 138.05 [Endpoint 0] 21:01:31.897 CNTRLR [Node 026] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 21:01:31.897 SERIAL » [ACK] (0x06) 21:01:31.900 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 138.05 time delta: 0 seconds 21:01:31.913 SERIAL « 0x010c0004001a0631050422103fd6 (14 bytes) 21:01:31.913 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:01:31.914 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 221.9 => 415.9 [Endpoint 0] 21:01:31.914 SERIAL » [ACK] (0x06) 21:01:31.914 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 415.9 21:01:32.894 SERIAL « 0x010c0004001a06310504220a798a (14 bytes) 21:01:32.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:01:32.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 415.9 => 268.1 [Endpoint 0] 21:01:32.896 SERIAL » [ACK] (0x06) 21:01:32.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 268.1 21:01:34.894 SERIAL « 0x010c0004001a06310504220fa751 (14 bytes) 21:01:34.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:01:34.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 268.1 => 400.7 [Endpoint 0] 21:01:34.897 SERIAL » [ACK] (0x06) 21:01:34.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 400.7 21:01:35.191 SERIAL « 0x0109000400200380032f7d (11 bytes) 21:01:35.192 CNTRLR [Node 032] [~] [Battery] level: 47 => 47 [Endpoint 0] 21:01:35.192 CNTRLR [Node 032] [~] [Battery] isLow: false => false [Endpoint 0] 21:01:35.193 SERIAL » [ACK] (0x06) 21:01:35.193 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 47 is low: false 21:01:35.240 SERIAL « 0x010c000400200631050142072e8f (14 bytes) 21:01:35.241 CNTRLR [Node 032] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 21:01:35.241 CNTRLR [Node 032] [~] [Multilevel Sensor] Air temperature: 18.36 => 18.3 [Endpoint 0] 8 21:01:35.242 SERIAL » [ACK] (0x06) 21:01:35.243 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.38 21:01:35.265 SERIAL « 0x01080004002002840752 (10 bytes) 21:01:35.266 SERIAL » [ACK] (0x06) 21:01:35.267 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 21:01:35.268 CNTRLR « [Node 032] received wakeup notification 21:01:35.268 CNTRLR [Node 032] The node is now awake. 21:01:35.275 SERIAL » 0x0104006020bb (6 bytes) 21:01:35.275 DRIVER » [Node 032] [REQ] [RequestNodeInfo] payload: 0x20 21:01:35.277 SERIAL « [ACK] (0x06) 21:01:35.281 SERIAL « 0x01040160019b (6 bytes) 21:01:35.281 SERIAL » [ACK] (0x06) 21:01:35.282 DRIVER « [RES] [RequestNodeInfo] payload: 0x01 21:01:35.310 SERIAL « 0x01160049842010042101207286808f847570315b43538797 (24 bytes) 21:01:35.310 SERIAL » [ACK] (0x06) 21:01:35.310 DRIVER « [Node 032] [REQ] [ApplicationUpdateRequest] payload: 0x842010042101207286808f847570315b435387 21:01:35.313 SERIAL » 0x0109001320028405253053 (11 bytes) 21:01:35.313 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 48 └─[WakeUpCCIntervalGet] 21:01:35.313 CNTRLR « [Node 032] node info received supported CCs: · Basic · Manufacturer Specific · Version · Battery · Multi Command · Wake Up · Protection · Configuration · Multilevel Sensor · Central Scene · Thermostat Setpoint · Schedule · Indicator controlled CCs: 21:01:35.316 SERIAL « [ACK] (0x06) 21:01:35.317 CNTRLR [Node 032] Interview stage completed: NodeInfo 21:01:35.319 CNTRLR [Node 032] ManufacturerSpecificCC: doing a complete interview... 21:01:35.319 CNTRLR » [Node 032] querying manufacturer information... 21:01:35.320 SERIAL « 0x0104011301e8 (6 bytes) 21:01:35.320 SERIAL » [ACK] (0x06) 21:01:35.320 DRIVER « [RES] [SendData] was sent: true 21:01:35.334 SERIAL « 0x0107001330000002d9 (9 bytes) 21:01:35.334 SERIAL » [ACK] (0x06) 21:01:35.334 DRIVER « [REQ] [SendData] callback id: 48 transmit status: OK 21:01:35.351 SERIAL « 0x010c00040020068406000708015d (14 bytes) 21:01:35.352 CNTRLR [Node 032] [+] [Wake Up] wakeUpInterval: 1800 [Endpoint 0] 21:01:35.352 CNTRLR [Node 032] [+] [Wake Up] controllerNodeId: 1 [Endpoint 0] 21:01:35.352 SERIAL » [ACK] (0x06) 21:01:35.353 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 1800 seconds controller node id: 1 21:01:35.355 SERIAL » 0x01090013200272042531a5 (11 bytes) 21:01:35.355 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 49 └─[ManufacturerSpecificCCGet] 21:01:35.356 SERIAL « [ACK] (0x06) 21:01:35.360 SERIAL « 0x0104011301e8 (6 bytes) 21:01:35.360 SERIAL » [ACK] (0x06) 21:01:35.361 DRIVER « [RES] [SendData] was sent: true 21:01:35.377 SERIAL « 0x0107001331000002d8 (9 bytes) 21:01:35.377 SERIAL » [ACK] (0x06) 21:01:35.377 DRIVER « [REQ] [SendData] callback id: 49 transmit status: OK 21:01:35.394 SERIAL « 0x010e000400200872050002000380103b (16 bytes) 21:01:35.395 CNTRLR [Node 032] [+] [Manufacturer Specific] manufacturerId: 2 [Endpoint 0] 21:01:35.395 CNTRLR [Node 032] [+] [Manufacturer Specific] productType: 3 [Endpoint 0] 21:01:35.396 CNTRLR [Node 032] [+] [Manufacturer Specific] productId: 32784 [Endpoint 0] 21:01:35.396 SERIAL » [ACK] (0x06) 21:01:35.396 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ManufacturerSpecificCCReport] manufacturer id: 0x02 product type: 0x03 product id: 0x8010 21:01:35.398 CNTRLR « [Node 032] received response for manufacturer information: manufacturer: Danfoss (0x02) product type: 0x03 product id: 0x8010 21:01:35.398 CNTRLR [Node 032] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 21:01:35.398 CNTRLR [Node 032] VersionCC: doing a complete interview... 21:01:35.398 CNTRLR » [Node 032] querying node versions... 21:01:35.400 SERIAL » 0x0109001320028611253247 (11 bytes) 21:01:35.401 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 50 └─[VersionCCGet] 21:01:35.401 SERIAL « [ACK] (0x06) 21:01:35.406 SERIAL « 0x0104011301e8 (6 bytes) 21:01:35.406 SERIAL » [ACK] (0x06) 21:01:35.406 DRIVER « [RES] [SendData] was sent: true 21:01:35.422 SERIAL « 0x0107001332000002db (9 bytes) 21:01:35.422 SERIAL » [ACK] (0x06) 21:01:35.422 DRIVER « [REQ] [SendData] callback id: 50 transmit status: OK 21:01:35.443 SERIAL « 0x0111000400200b861206034301000101020212 (19 bytes) 21:01:35.444 CNTRLR [Node 032] [+] [Version] libraryType: 6 [Endpoint 0] 21:01:35.444 CNTRLR [Node 032] [+] [Version] protocolVersion: "3.67" [Endpoint 0] 21:01:35.445 CNTRLR [Node 032] [+] [Version] firmwareVersions: 1.0 [Endpoint 0] 21:01:35.446 SERIAL » [ACK] (0x06) 21:01:35.446 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[VersionCCReport] library type: Routing Slave protocol version: 3.67 firmware versions: 1.0 21:01:35.452 CNTRLR « [Node 032] received response for node versions: library type: Routing Slave (0x06) protocol version: 3.67 firmware versions: 1.0 21:01:35.452 CNTRLR » [Node 032] querying CC versions... 21:01:35.453 CNTRLR » [Node 032] querying the CC version for Multilevel Sensor (0x31)... 21:01:35.458 SERIAL » 0x010a00132003861331253377 (12 bytes) 21:01:35.459 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 51 └─[VersionCCCommandClassGet] CC: Multilevel Sensor 21:01:35.461 SERIAL « [ACK] (0x06) 21:01:35.465 SERIAL « 0x0104011301e8 (6 bytes) 21:01:35.465 SERIAL » [ACK] (0x06) 21:01:35.466 DRIVER « [RES] [SendData] was sent: true 21:01:35.480 SERIAL « 0x0107001333000002da (9 bytes) 21:01:35.480 SERIAL » [ACK] (0x06) 21:01:35.481 DRIVER « [REQ] [SendData] callback id: 51 transmit status: OK 21:01:35.497 SERIAL « 0x010a00040020048614310670 (12 bytes) 21:01:35.497 SERIAL » [ACK] (0x06) 21:01:35.498 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multilevel Sensor version: 6 21:01:35.498 CNTRLR [Node 032] supports CC Multilevel Sensor (0x31) in version 6 21:01:35.498 CNTRLR » [Node 032] querying the CC version for Wake Up (0x84)... 21:01:35.501 SERIAL » 0x010a001320038613842534c5 (12 bytes) 21:01:35.501 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 52 └─[VersionCCCommandClassGet] CC: Wake Up 21:01:35.502 SERIAL « [ACK] (0x06) 21:01:35.506 SERIAL « 0x0104011301e8 (6 bytes) 21:01:35.507 SERIAL » [ACK] (0x06) 21:01:35.507 DRIVER « [RES] [SendData] was sent: true 21:01:35.522 SERIAL « 0x0107001334000002dd (9 bytes) 21:01:35.522 SERIAL » [ACK] (0x06) 21:01:35.523 DRIVER « [REQ] [SendData] callback id: 52 transmit status: OK 21:01:35.539 SERIAL « 0x010a000400200486148402c1 (12 bytes) 21:01:35.539 SERIAL » [ACK] (0x06) 21:01:35.539 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Wake Up version: 2 21:01:35.540 CNTRLR [Node 032] supports CC Wake Up (0x84) in version 2 21:01:35.540 CNTRLR » [Node 032] querying the CC version for Manufacturer Specific (0x72)... 21:01:35.543 SERIAL » 0x010a00132003861372253532 (12 bytes) 21:01:35.543 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 53 └─[VersionCCCommandClassGet] CC: Manufacturer Specific 21:01:35.545 SERIAL « [ACK] (0x06) 21:01:35.553 SERIAL « 0x0104011301e8 (6 bytes) 21:01:35.553 SERIAL » [ACK] (0x06) 21:01:35.553 DRIVER « [RES] [SendData] was sent: true 21:01:35.565 SERIAL « 0x0107001335000002dc (9 bytes) 21:01:35.565 SERIAL » [ACK] (0x06) 21:01:35.565 DRIVER « [REQ] [SendData] callback id: 53 transmit status: OK 21:01:35.581 SERIAL « 0x010a00040020048614720237 (12 bytes) 21:01:35.582 SERIAL » [ACK] (0x06) 21:01:35.582 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 2 21:01:35.583 CNTRLR [Node 032] supports CC Manufacturer Specific (0x72) in version 2 21:01:35.583 CNTRLR » [Node 032] querying the CC version for Version (0x86)... 21:01:35.587 SERIAL » 0x010a001320038613862536c5 (12 bytes) 21:01:35.588 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 54 └─[VersionCCCommandClassGet] CC: Version 21:01:35.589 SERIAL « [ACK] (0x06) 21:01:35.593 SERIAL « 0x0104011301e8 (6 bytes) 21:01:35.593 SERIAL » [ACK] (0x06) 21:01:35.594 DRIVER « [RES] [SendData] was sent: true 21:01:35.609 SERIAL « 0x0107001336000002df (9 bytes) 21:01:35.610 SERIAL » [ACK] (0x06) 21:01:35.610 DRIVER « [REQ] [SendData] callback id: 54 transmit status: OK 21:01:35.894 SERIAL « 0x010c0004001a063105042207f00e (14 bytes) 21:01:35.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:01:35.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 400.7 => 203.2 [Endpoint 0] 21:01:35.896 SERIAL » [ACK] (0x06) 21:01:35.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 203.2 21:01:36.894 SERIAL « 0x010c0004001a0631050422098676 (14 bytes) 21:01:36.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:01:36.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 203.2 => 243.8 [Endpoint 0] 21:01:36.896 SERIAL » [ACK] (0x06) 21:01:36.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 243.8 21:01:37.213 CNTRLR [Node 032] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 21:01:37.672 SERIAL « 0x010a000400200486148602c3 (12 bytes) 21:01:37.673 SERIAL » [ACK] (0x06) 21:01:37.673 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 2 21:01:37.717 SERIAL » 0x010a001320038613862536c5 (12 bytes) 21:01:37.717 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 54 └─[VersionCCCommandClassGet] CC: Version 21:01:37.718 SERIAL « [ACK] (0x06) 21:01:37.723 SERIAL « 0x0104011301e8 (6 bytes) 21:01:37.723 SERIAL » [ACK] (0x06) 21:01:37.724 DRIVER « [RES] [SendData] was sent: true 21:01:37.739 SERIAL « 0x0107001336000002df (9 bytes) 21:01:37.739 SERIAL » [ACK] (0x06) 21:01:37.740 DRIVER « [REQ] [SendData] callback id: 54 transmit status: OK 21:01:37.755 SERIAL « 0x010a000400200486148602c3 (12 bytes) 21:01:37.756 SERIAL » [ACK] (0x06) 21:01:37.756 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 2 21:01:37.758 CNTRLR [Node 032] supports CC Version (0x86) in version 2 21:01:37.758 CNTRLR » [Node 032] querying the CC version for Battery (0x80)... 21:01:37.761 SERIAL » 0x010a001320038613802537c2 (12 bytes) 21:01:37.762 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 55 └─[VersionCCCommandClassGet] CC: Battery 21:01:37.763 SERIAL « [ACK] (0x06) 21:01:37.767 SERIAL « 0x0104011301e8 (6 bytes) 21:01:37.767 SERIAL » [ACK] (0x06) 21:01:37.768 DRIVER « [RES] [SendData] was sent: true 21:01:37.783 SERIAL « 0x0107001337000002de (9 bytes) 21:01:37.783 SERIAL » [ACK] (0x06) 21:01:37.784 DRIVER « [REQ] [SendData] callback id: 55 transmit status: OK 21:01:37.800 SERIAL « 0x010a000400200486148001c6 (12 bytes) 21:01:37.800 SERIAL » [ACK] (0x06) 21:01:37.801 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Battery version: 1 21:01:37.802 CNTRLR [Node 032] supports CC Battery (0x80) in version 1 21:01:37.802 CNTRLR [Node 032] skipping query for Multi Command (0x8f) because max implemented v ersion is 1 21:01:37.802 CNTRLR » [Node 032] querying the CC version for Protection (0x75)... 21:01:37.806 SERIAL » 0x010a00132003861375253838 (12 bytes) 21:01:37.806 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 56 └─[VersionCCCommandClassGet] CC: Protection 21:01:37.807 SERIAL « [ACK] (0x06) 21:01:37.812 SERIAL « 0x0104011301e8 (6 bytes) 21:01:37.812 SERIAL » [ACK] (0x06) 21:01:37.812 DRIVER « [RES] [SendData] was sent: true 21:01:37.827 SERIAL « 0x0107001338000001d2 (9 bytes) 21:01:37.828 SERIAL » [ACK] (0x06) 21:01:37.828 DRIVER « [REQ] [SendData] callback id: 56 transmit status: OK 21:01:37.843 SERIAL « 0x010a00040020048614750230 (12 bytes) 21:01:37.844 SERIAL » [ACK] (0x06) 21:01:37.845 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Protection version: 2 21:01:37.846 CNTRLR [Node 032] supports CC Protection (0x75) in version 2 21:01:37.846 CNTRLR » [Node 032] querying the CC version for Configuration (0x70)... 21:01:37.852 SERIAL » 0x010a0013200386137025393c (12 bytes) 21:01:37.852 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 57 └─[VersionCCCommandClassGet] CC: Configuration 21:01:37.853 SERIAL « [ACK] (0x06) 21:01:37.857 SERIAL « 0x0104011301e8 (6 bytes) 21:01:37.858 SERIAL » [ACK] (0x06) 21:01:37.858 DRIVER « [RES] [SendData] was sent: true 21:01:37.874 SERIAL « 0x0107001339000002d0 (9 bytes) 21:01:37.874 SERIAL » [ACK] (0x06) 21:01:37.874 DRIVER « [REQ] [SendData] callback id: 57 transmit status: OK 21:01:37.890 SERIAL « 0x010a00040020048614700235 (12 bytes) 21:01:37.891 SERIAL » [ACK] (0x06) 21:01:37.891 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Configuration version: 2 21:01:37.892 CNTRLR [Node 032] supports CC Configuration (0x70) in version 2 21:01:37.893 CNTRLR » [Node 032] querying the CC version for Central Scene (0x5b)... 21:01:37.896 SERIAL » 0x010a0013200386135b253a14 (12 bytes) 21:01:37.896 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 58 └─[VersionCCCommandClassGet] CC: Central Scene 21:01:37.897 SERIAL « [ACK] (0x06) 21:01:37.901 SERIAL « 0x0104011301e8 (6 bytes) 21:01:37.902 SERIAL » [ACK] (0x06) 21:01:37.902 DRIVER « [RES] [SendData] was sent: true 21:01:37.917 SERIAL « 0x010700133a000001d0 (9 bytes) 21:01:37.918 SERIAL » [ACK] (0x06) 21:01:37.918 DRIVER « [REQ] [SendData] callback id: 58 transmit status: OK 21:01:37.934 SERIAL « 0x010a000400200486145b011d (12 bytes) 21:01:37.934 SERIAL » [ACK] (0x06) 21:01:37.935 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Central Scene version: 1 21:01:37.936 CNTRLR [Node 032] supports CC Central Scene (0x5b) in version 1 21:01:37.937 CNTRLR » [Node 032] querying the CC version for Thermostat Setpoint (0x43)... 21:01:37.940 SERIAL » 0x010a00132003861343253b0d (12 bytes) 21:01:37.940 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 59 └─[VersionCCCommandClassGet] CC: Thermostat Setpoint 21:01:37.941 SERIAL « [ACK] (0x06) 21:01:37.945 SERIAL « 0x0104011301e8 (6 bytes) 21:01:37.946 SERIAL » [ACK] (0x06) 21:01:37.946 DRIVER « [RES] [SendData] was sent: true 21:01:37.961 SERIAL « 0x010700133b000002d2 (9 bytes) 21:01:37.962 SERIAL » [ACK] (0x06) 21:01:37.962 DRIVER « [REQ] [SendData] callback id: 59 transmit status: OK 21:01:37.978 SERIAL « 0x010a00040020048614430307 (12 bytes) 21:01:37.979 SERIAL » [ACK] (0x06) 21:01:37.979 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Thermostat Setpoint version: 3 21:01:37.980 CNTRLR [Node 032] supports CC Thermostat Setpoint (0x43) in version 3 21:01:37.981 CNTRLR [Node 032] skipping query for Schedule (0x53) because max implemented versio n is 0 21:01:37.981 CNTRLR » [Node 032] querying the CC version for Indicator (0x87)... 21:01:37.987 SERIAL » 0x010a00132003861387253cce (12 bytes) 21:01:37.988 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 60 └─[VersionCCCommandClassGet] CC: Indicator 21:01:37.989 SERIAL « [ACK] (0x06) 21:01:37.993 SERIAL « 0x0104011301e8 (6 bytes) 21:01:37.993 SERIAL » [ACK] (0x06) 21:01:37.993 DRIVER « [RES] [SendData] was sent: true 21:01:38.009 SERIAL « 0x010700133c000002d5 (9 bytes) 21:01:38.009 SERIAL » [ACK] (0x06) 21:01:38.010 DRIVER « [REQ] [SendData] callback id: 60 transmit status: OK 21:01:38.026 SERIAL « 0x010a000400200486148701c1 (12 bytes) 21:01:38.026 SERIAL » [ACK] (0x06) 21:01:38.027 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Indicator version: 1 21:01:38.027 CNTRLR [Node 032] supports CC Indicator (0x87) in version 1 21:01:38.027 CNTRLR [Node 032] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 21:01:38.028 CNTRLR [Node 032] trying to load device config 21:01:38.031 CNTRLR [Node 032] device config loaded 21:01:38.035 CNTRLR [Node 032] WakeUpCC: doing a complete interview... 21:01:38.036 CNTRLR » [Node 032] retrieving wakeup capabilities from the device... 21:01:38.038 SERIAL » 0x0109001320028409253d52 (11 bytes) 21:01:38.038 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 61 └─[WakeUpCCIntervalCapabilitiesGet] 21:01:38.039 SERIAL « [ACK] (0x06) 21:01:38.043 SERIAL « 0x0104011301e8 (6 bytes) 21:01:38.043 SERIAL » [ACK] (0x06) 21:01:38.043 DRIVER « [RES] [SendData] was sent: true 21:01:38.059 SERIAL « 0x010700133d000002d4 (9 bytes) 21:01:38.059 SERIAL » [ACK] (0x06) 21:01:38.060 DRIVER « [REQ] [SendData] callback id: 61 transmit status: OK 21:01:38.081 SERIAL « 0x0114000400200e840a00012c015180000e10000001ad (22 bytes) 21:01:38.082 CNTRLR [Node 032] [Wake Up] wakeUpInterval: metadata updated [Endpoint 0] 21:01:38.083 SERIAL » [ACK] (0x06) 21:01:38.083 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalCapabilitiesReport] default interval: 3600 seconds minimum interval: 300 seconds maximum interval: 86400 seconds interval steps: 1 seconds 21:01:38.085 CNTRLR « [Node 032] received wakeup capabilities: default wakeup interval: 3600 seconds minimum wakeup interval: 300 seconds maximum wakeup interval: 86400 seconds wakeup interval steps: 1 seconds 21:01:38.085 CNTRLR » [Node 032] retrieving wakeup interval from the device... 21:01:38.088 SERIAL » 0x0109001320028405253e5d (11 bytes) 21:01:38.088 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 62 └─[WakeUpCCIntervalGet] 21:01:38.090 SERIAL « [ACK] (0x06) 21:01:38.094 SERIAL « 0x0104011301e8 (6 bytes) 21:01:38.094 SERIAL » [ACK] (0x06) 21:01:38.094 DRIVER « [RES] [SendData] was sent: true 21:01:38.109 SERIAL « 0x010700133e000002d7 (9 bytes) 21:01:38.110 SERIAL » [ACK] (0x06) 21:01:38.110 DRIVER « [REQ] [SendData] callback id: 62 transmit status: OK 21:01:38.127 SERIAL « 0x010c00040020068406000708015d (14 bytes) 21:01:38.128 CNTRLR [Node 032] [~] [Wake Up] wakeUpInterval: 1800 => 1800 [Endpoint 0] 21:01:38.128 CNTRLR [Node 032] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 21:01:38.128 SERIAL » [ACK] (0x06) 21:01:38.129 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 1800 seconds controller node id: 1 21:01:38.130 CNTRLR « [Node 032] received wakeup configuration: wakeup interval: 1800 seconds controller node: 1 21:01:38.131 CNTRLR [Node 032] [+] [Wake Up] interviewComplete: true [Endpoint 0] [internal] 21:01:38.131 CNTRLR [Node 032] BatteryCC: doing a complete interview... 21:01:38.131 CNTRLR » [Node 032] querying battery status... 21:01:38.137 SERIAL » 0x0109001320028002253f5f (11 bytes) 21:01:38.137 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 63 └─[BatteryCCGet] 21:01:38.138 SERIAL « [ACK] (0x06) 21:01:38.142 SERIAL « 0x0104011301e8 (6 bytes) 21:01:38.142 SERIAL » [ACK] (0x06) 21:01:38.143 DRIVER « [RES] [SendData] was sent: true 21:01:38.158 SERIAL « 0x010700133f000002d6 (9 bytes) 21:01:38.159 SERIAL » [ACK] (0x06) 21:01:38.159 DRIVER « [REQ] [SendData] callback id: 63 transmit status: OK 21:01:38.174 SERIAL « 0x0109000400200380032f7d (11 bytes) 21:01:38.175 CNTRLR [Node 032] [~] [Battery] level: 47 => 47 [Endpoint 0] 21:01:38.175 CNTRLR [Node 032] [~] [Battery] isLow: false => false [Endpoint 0] 21:01:38.176 SERIAL » [ACK] (0x06) 21:01:38.177 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 47 is low: false 21:01:38.178 CNTRLR « [Node 032] received response for battery information: level: 47 21:01:38.178 CNTRLR [Node 032] [+] [Battery] interviewComplete: true [Endpoint 0] [internal] 21:01:38.179 CNTRLR [Node 032] IndicatorCC: doing a complete interview... 21:01:38.180 CNTRLR » [Node 032] requesting current indicator value... 21:01:38.196 SERIAL » 0x0109001320028702254027 (11 bytes) 21:01:38.196 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 64 └─[IndicatorCCGet] indicator: 0 (default) 21:01:38.208 SERIAL « [ACK] (0x06) 21:01:38.208 SERIAL « 0x0104011301e8 (6 bytes) 21:01:38.209 SERIAL » [ACK] (0x06) 21:01:38.209 DRIVER « [RES] [SendData] was sent: true 21:01:38.217 SERIAL « 0x0107001340000001aa (9 bytes) 21:01:38.217 SERIAL » [ACK] (0x06) 21:01:38.217 DRIVER « [REQ] [SendData] callback id: 64 transmit status: OK 21:01:38.233 SERIAL « 0x0109000400200387030055 (11 bytes) 21:01:38.234 CNTRLR [Node 032] [Indicator] value: metadata updated [Endpoint 0] 21:01:38.235 CNTRLR [Node 032] [+] [Indicator] value: 0 [Endpoint 0] 21:01:38.235 SERIAL » [ACK] (0x06) 21:01:38.236 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[IndicatorCCReport] indicator 0 value: 0 21:01:38.240 CNTRLR [Node 032] [+] [Indicator] interviewComplete: true [Endpoint 0] [internal] 21:01:38.253 CNTRLR [Node 032] MultilevelSensorCC: doing a complete interview... 21:01:38.253 CNTRLR » [Node 032] retrieving supported sensor types... 21:01:38.256 SERIAL » 0x0109001320023101254193 (11 bytes) 21:01:38.256 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 65 └─[MultilevelSensorCCGetSupportedSensor] 21:01:38.257 SERIAL « [ACK] (0x06) 21:01:38.261 SERIAL « 0x0104011301e8 (6 bytes) 21:01:38.261 SERIAL » [ACK] (0x06) 21:01:38.261 DRIVER « [RES] [SendData] was sent: true 21:01:38.277 SERIAL « 0x0107001341000002a8 (9 bytes) 21:01:38.277 SERIAL » [ACK] (0x06) 21:01:38.277 DRIVER « [REQ] [SendData] callback id: 65 transmit status: OK 21:01:38.292 SERIAL « 0x01090004002003310201e3 (11 bytes) 21:01:38.293 CNTRLR [Node 032] [+] [Multilevel Sensor] supportedSensorType [Endpoint 0] [internal] s: 1 21:01:38.293 SERIAL » [ACK] (0x06) 21:01:38.293 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedSensorReport] supported sensor types: · Air temperature 21:01:38.294 CNTRLR « [Node 032] received supported sensor types: · Air temperature 21:01:38.294 CNTRLR » [Node 032] querying supported scales for Air temperature sensor 21:01:38.296 SERIAL » 0x010a00132003310301254291 (12 bytes) 21:01:38.296 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 66 └─[MultilevelSensorCCGetSupportedScale] sensor type: Air temperature 21:01:38.297 SERIAL « [ACK] (0x06) 21:01:38.301 SERIAL « 0x0104011301e8 (6 bytes) 21:01:38.301 SERIAL » [ACK] (0x06) 21:01:38.302 DRIVER « [RES] [SendData] was sent: true 21:01:38.318 SERIAL « 0x0107001342000003aa (9 bytes) 21:01:38.318 SERIAL » [ACK] (0x06) 21:01:38.318 DRIVER « [REQ] [SendData] callback id: 66 transmit status: OK 21:01:38.334 SERIAL « 0x010a000400200431060100e3 (12 bytes) 21:01:38.335 CNTRLR [Node 032] [+] [Multilevel Sensor] supportedScales[1]: [Endpoint 0] [internal] 21:01:38.335 SERIAL » [ACK] (0x06) 21:01:38.336 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[MultilevelSensorCCSupportedScaleReport] sensor type: Air temperature supported scales: 21:01:38.337 CNTRLR « [Node 032] received supported scales: 21:01:38.337 CNTRLR » [Node 032] querying Air temperature sensor reading... 21:01:38.341 SERIAL » 0x0109001320023104254394 (11 bytes) 21:01:38.342 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 67 └─[MultilevelSensorCCGet] 21:01:38.343 SERIAL « [ACK] (0x06) 21:01:38.347 SERIAL « 0x0104011301e8 (6 bytes) 21:01:38.347 SERIAL » [ACK] (0x06) 21:01:38.348 DRIVER « [RES] [SendData] was sent: true 21:01:38.363 SERIAL « 0x0107001343000002aa (9 bytes) 21:01:38.363 SERIAL » [ACK] (0x06) 21:01:38.364 DRIVER « [REQ] [SendData] callback id: 67 transmit status: OK 21:01:38.380 SERIAL « 0x010c000400200631050142072e8f (14 bytes) 21:01:38.381 CNTRLR [Node 032] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 21:01:38.382 CNTRLR [Node 032] [~] [Multilevel Sensor] Air temperature: 18.38 => 18.3 [Endpoint 0] 8 21:01:38.382 SERIAL » [ACK] (0x06) 21:01:38.383 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.38 21:01:38.385 CNTRLR « [Node 032] received current Air temperature sensor reading: 18.38 21:01:38.385 CNTRLR [Node 032] [+] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true 21:01:38.386 CNTRLR [Node 032] ProtectionCC: doing a complete interview... 21:01:38.386 CNTRLR » [Node 032] querying protection capabilities... 21:01:38.389 SERIAL » 0x01090013200275042544d7 (11 bytes) 21:01:38.390 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 68 └─[ProtectionCCSupportedGet] 21:01:38.391 SERIAL « [ACK] (0x06) 21:01:38.397 SERIAL « 0x0104011301e8 (6 bytes) 21:01:38.397 SERIAL » [ACK] (0x06) 21:01:38.397 DRIVER « [RES] [SendData] was sent: true 21:01:38.411 SERIAL « 0x0107001344000002ad (9 bytes) 21:01:38.411 SERIAL » [ACK] (0x06) 21:01:38.412 DRIVER « [REQ] [SendData] callback id: 68 transmit status: OK 21:01:38.428 SERIAL « 0x010d000400200775050005000100a5 (15 bytes) 21:01:38.430 CNTRLR [Node 032] [+] [Protection] supportsExclusiveControl: [Endpoint 0] [internal] false 21:01:38.430 CNTRLR [Node 032] [+] [Protection] supportsTimeout: false [Endpoint 0] [internal] 21:01:38.430 CNTRLR [Node 032] [+] [Protection] supportedLocalStates: 0,2 [Endpoint 0] [internal] 21:01:38.430 CNTRLR [Node 032] [+] [Protection] supportedRFStates: 0 [Endpoint 0] [internal] 21:01:38.431 CNTRLR [Node 032] [Protection] local: metadata updated [Endpoint 0] 21:01:38.432 CNTRLR [Node 032] [Protection] rf: metadata updated [Endpoint 0] 21:01:38.433 SERIAL » [ACK] (0x06) 21:01:38.434 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ProtectionCCSupportedReport] supports exclusive control: false supports timeout: false local protection states: · Unprotected · NoOperationPossible RF protection states: · Unprotected 21:01:38.436 CNTRLR « [Node 032] received protection capabilities: exclusive control: false timeout: false local protection states: · Unprotected · NoOperationPossible RF protection states: · Unprotected 21:01:38.436 CNTRLR » [Node 032] querying protection status... 21:01:38.440 SERIAL » 0x01090013200275022545d0 (11 bytes) 21:01:38.440 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 69 └─[ProtectionCCGet] 21:01:38.450 SERIAL « [ACK] (0x06) 21:01:38.451 SERIAL « 0x0104011301e8 (6 bytes) 21:01:38.451 SERIAL » [ACK] (0x06) 21:01:38.452 DRIVER « [RES] [SendData] was sent: true 21:01:38.461 SERIAL « 0x0107001345000002ac (9 bytes) 21:01:38.461 SERIAL » [ACK] (0x06) 21:01:38.462 DRIVER « [REQ] [SendData] callback id: 69 transmit status: OK 21:01:38.478 SERIAL « 0x010a000400200475030000a3 (12 bytes) 21:01:38.478 CNTRLR [Node 032] [+] [Protection] local: 0 [Endpoint 0] 21:01:38.479 CNTRLR [Node 032] [+] [Protection] rf: 0 [Endpoint 0] 21:01:38.479 SERIAL » [ACK] (0x06) 21:01:38.480 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 21:01:38.480 CNTRLR « [Node 032] received protection status: local: Unprotected rf Unprotected 21:01:38.481 CNTRLR [Node 032] [+] [Protection] interviewComplete: true [Endpoint 0] [internal] 21:01:38.481 CNTRLR [Node 032] ConfigurationCC: Loading configuration parameters from device confi g 21:01:38.482 CNTRLR [Node 032] [+] [Configuration] isParamInformationFromConfig: false [internal] 21:01:38.482 CNTRLR [Node 032] [Configuration] 1: metadata updated 21:01:38.483 CNTRLR [Node 032] [Configuration] 2: metadata updated 21:01:38.483 CNTRLR [Node 032] [Configuration] 3: metadata updated 21:01:38.485 CNTRLR [Node 032] [Configuration] 4: metadata updated 21:01:38.486 CNTRLR [Node 032] [Configuration] 5: metadata updated 21:01:38.486 CNTRLR [Node 032] [Configuration] 6: metadata updated 21:01:38.486 CNTRLR [Node 032] [Configuration] 7: metadata updated 21:01:38.487 CNTRLR [Node 032] [Configuration] 8: metadata updated 21:01:38.487 CNTRLR [Node 032] [Configuration] 9: metadata updated 21:01:38.488 CNTRLR [Node 032] [Configuration] 10: metadata updated 21:01:38.488 CNTRLR [Node 032] [Configuration] 11: metadata updated 21:01:38.488 CNTRLR [Node 032] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 21:01:38.489 CNTRLR » [Node 032] querying parameter #1 value... 21:01:38.490 SERIAL » 0x010a001320037005012546d2 (12 bytes) 21:01:38.491 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 70 └─[ConfigurationCCGet] parameter #: 1 21:01:38.494 SERIAL « [ACK] (0x06) 21:01:38.497 SERIAL « 0x0104011301e8 (6 bytes) 21:01:38.497 SERIAL » [ACK] (0x06) 21:01:38.497 DRIVER « [RES] [SendData] was sent: true 21:01:38.512 SERIAL « 0x0107001346000002af (9 bytes) 21:01:38.512 SERIAL » [ACK] (0x06) 21:01:38.513 DRIVER « [REQ] [SendData] callback id: 70 transmit status: OK 21:01:38.538 SERIAL « 0x010c0004002006700601020005a1 (14 bytes) 21:01:38.541 CNTRLR [Node 032] [+] [Configuration] 1: 5 21:01:38.541 SERIAL » [ACK] (0x06) 21:01:38.542 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 2 value: 5 21:01:38.543 CNTRLR « [Node 032] parameter #1 has value: 5 21:01:38.544 CNTRLR » [Node 032] querying parameter #2 value... 21:01:38.547 SERIAL » 0x010a001320037005022547d0 (12 bytes) 21:01:38.547 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 71 └─[ConfigurationCCGet] parameter #: 2 21:01:38.548 SERIAL « [ACK] (0x06) 21:01:38.553 SERIAL « 0x0104011301e8 (6 bytes) 21:01:38.553 SERIAL » [ACK] (0x06) 21:01:38.554 DRIVER « [RES] [SendData] was sent: true 21:01:38.569 SERIAL « 0x0107001347000002ae (9 bytes) 21:01:38.569 SERIAL » [ACK] (0x06) 21:01:38.569 DRIVER « [REQ] [SendData] callback id: 71 transmit status: OK 21:01:38.587 SERIAL « 0x010c0004002006700602020005a2 (14 bytes) 21:01:38.589 CNTRLR [Node 032] [+] [Configuration] 2: 5 21:01:38.590 SERIAL » [ACK] (0x06) 21:01:38.590 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 2 value: 5 21:01:38.592 CNTRLR « [Node 032] parameter #2 has value: 5 21:01:38.592 CNTRLR » [Node 032] querying parameter #3 value... 21:01:38.595 SERIAL » 0x010a001320037005032548de (12 bytes) 21:01:38.596 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 72 └─[ConfigurationCCGet] parameter #: 3 21:01:38.597 SERIAL « [ACK] (0x06) 21:01:38.601 SERIAL « 0x0104011301e8 (6 bytes) 21:01:38.601 SERIAL » [ACK] (0x06) 21:01:38.604 DRIVER « [RES] [SendData] was sent: true 21:01:38.617 SERIAL « 0x0107001348000002a1 (9 bytes) 21:01:38.617 SERIAL » [ACK] (0x06) 21:01:38.618 DRIVER « [REQ] [SendData] callback id: 72 transmit status: OK 21:01:38.646 SERIAL « 0x010c000400200670060302000caa (14 bytes) 21:01:38.648 CNTRLR [Node 032] [+] [Configuration] 3: 12 21:01:38.649 SERIAL » [ACK] (0x06) 21:01:38.650 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 2 value: 12 21:01:38.652 CNTRLR « [Node 032] parameter #3 has value: 12 21:01:38.652 CNTRLR » [Node 032] querying parameter #4 value... 21:01:38.655 SERIAL » 0x010a001320037005042549d8 (12 bytes) 21:01:38.656 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 73 └─[ConfigurationCCGet] parameter #: 4 21:01:38.657 SERIAL « [ACK] (0x06) 21:01:38.661 SERIAL « 0x0104011301e8 (6 bytes) 21:01:38.661 SERIAL » [ACK] (0x06) 21:01:38.661 DRIVER « [RES] [SendData] was sent: true 21:01:38.677 SERIAL « 0x0107001349000002a0 (9 bytes) 21:01:38.677 SERIAL » [ACK] (0x06) 21:01:38.677 DRIVER « [REQ] [SendData] callback id: 73 transmit status: OK 21:01:38.694 SERIAL « 0x010c000400200670060402001cbd (14 bytes) 21:01:38.695 CNTRLR [Node 032] [+] [Configuration] 4: 28 21:01:38.695 SERIAL » [ACK] (0x06) 21:01:38.696 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 2 value: 28 21:01:38.696 CNTRLR « [Node 032] parameter #4 has value: 28 21:01:38.696 CNTRLR » [Node 032] querying parameter #5 value... 21:01:38.698 SERIAL » 0x010a00132003700505254ada (12 bytes) 21:01:38.698 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 74 └─[ConfigurationCCGet] parameter #: 5 21:01:38.699 SERIAL « [ACK] (0x06) 21:01:38.703 SERIAL « 0x0104011301e8 (6 bytes) 21:01:38.703 SERIAL » [ACK] (0x06) 21:01:38.704 DRIVER « [RES] [SendData] was sent: true 21:01:38.720 SERIAL « 0x010700134a000002a3 (9 bytes) 21:01:38.720 SERIAL » [ACK] (0x06) 21:01:38.720 DRIVER « [REQ] [SendData] callback id: 74 transmit status: OK 21:01:38.737 SERIAL « 0x010c0004002006700605020001a1 (14 bytes) 21:01:38.739 CNTRLR [Node 032] [+] [Configuration] 5: 1 21:01:38.740 SERIAL » [ACK] (0x06) 21:01:38.741 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 2 value: 1 21:01:38.742 CNTRLR « [Node 032] parameter #5 has value: 1 21:01:38.742 CNTRLR » [Node 032] querying parameter #6 value... 21:01:38.748 SERIAL » 0x010a00132003700506254bd8 (12 bytes) 21:01:38.748 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 75 └─[ConfigurationCCGet] parameter #: 6 21:01:38.749 SERIAL « [ACK] (0x06) 21:01:38.753 SERIAL « 0x0104011301e8 (6 bytes) 21:01:38.754 SERIAL » [ACK] (0x06) 21:01:38.754 DRIVER « [RES] [SendData] was sent: true 21:01:38.770 SERIAL « 0x010700134b000002a2 (9 bytes) 21:01:38.770 SERIAL » [ACK] (0x06) 21:01:38.770 DRIVER « [REQ] [SendData] callback id: 75 transmit status: OK 21:01:38.786 SERIAL « 0x010b00040020057006060101a5 (13 bytes) 21:01:38.789 CNTRLR [Node 032] [+] [Configuration] 6: 1 21:01:38.789 SERIAL » [ACK] (0x06) 21:01:38.790 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 1 value: 1 21:01:38.791 CNTRLR « [Node 032] parameter #6 has value: 1 21:01:38.791 CNTRLR » [Node 032] querying parameter #7 value... 21:01:38.795 SERIAL » 0x010a00132003700507254cde (12 bytes) 21:01:38.795 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 76 └─[ConfigurationCCGet] parameter #: 7 21:01:38.796 SERIAL « [ACK] (0x06) 21:01:38.800 SERIAL « 0x0104011301e8 (6 bytes) 21:01:38.801 SERIAL » [ACK] (0x06) 21:01:38.801 DRIVER « [RES] [SendData] was sent: true 21:01:38.816 SERIAL « 0x010700134c000002a5 (9 bytes) 21:01:38.817 SERIAL » [ACK] (0x06) 21:01:38.817 DRIVER « [REQ] [SendData] callback id: 76 transmit status: OK 21:01:38.833 SERIAL « 0x010b00040020057006070101a4 (13 bytes) 21:01:38.836 CNTRLR [Node 032] [+] [Configuration] 7: 1 21:01:38.836 SERIAL » [ACK] (0x06) 21:01:38.837 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 7 value size: 1 value: 1 21:01:38.838 CNTRLR « [Node 032] parameter #7 has value: 1 21:01:38.838 CNTRLR » [Node 032] querying parameter #8 value... 21:01:38.841 SERIAL » 0x010a00132003700508254dd0 (12 bytes) 21:01:38.842 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 77 └─[ConfigurationCCGet] parameter #: 8 21:01:38.843 SERIAL « [ACK] (0x06) 21:01:38.847 SERIAL « 0x0104011301e8 (6 bytes) 21:01:38.848 SERIAL » [ACK] (0x06) 21:01:38.848 DRIVER « [RES] [SendData] was sent: true 21:01:38.863 SERIAL « 0x010700134d000002a4 (9 bytes) 21:01:38.863 SERIAL » [ACK] (0x06) 21:01:38.863 DRIVER « [REQ] [SendData] callback id: 77 transmit status: OK 21:01:38.880 SERIAL « 0x010b00040020057006080101ab (13 bytes) 21:01:38.882 CNTRLR [Node 032] [+] [Configuration] 8: 1 21:01:38.883 SERIAL » [ACK] (0x06) 21:01:38.883 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 1 21:01:38.885 CNTRLR « [Node 032] parameter #8 has value: 1 21:01:38.885 CNTRLR » [Node 032] querying parameter #9 value... 21:01:38.890 SERIAL » 0x010a00132003700509254ed2 (12 bytes) 21:01:38.891 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 78 └─[ConfigurationCCGet] parameter #: 9 21:01:38.892 SERIAL « [ACK] (0x06) 21:01:38.896 SERIAL « 0x0104011301e8 (6 bytes) 21:01:38.896 SERIAL » [ACK] (0x06) 21:01:38.897 DRIVER « [RES] [SendData] was sent: true 21:01:38.912 SERIAL « 0x010700134e000002a7 (9 bytes) 21:01:38.912 SERIAL » [ACK] (0x06) 21:01:38.912 DRIVER « [REQ] [SendData] callback id: 78 transmit status: OK 21:01:38.928 SERIAL « 0x010b00040020057006090101aa (13 bytes) 21:01:38.929 CNTRLR [Node 032] [+] [Configuration] 9: 1 21:01:38.930 SERIAL » [ACK] (0x06) 21:01:38.930 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 1 value: 1 21:01:38.930 CNTRLR « [Node 032] parameter #9 has value: 1 21:01:38.931 CNTRLR » [Node 032] querying parameter #10 value... 21:01:38.932 SERIAL » 0x010a0013200370050a254fd0 (12 bytes) 21:01:38.932 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 79 └─[ConfigurationCCGet] parameter #: 10 21:01:38.933 SERIAL « [ACK] (0x06) 21:01:38.937 SERIAL « 0x0104011301e8 (6 bytes) 21:01:38.938 SERIAL » [ACK] (0x06) 21:01:38.938 DRIVER « [RES] [SendData] was sent: true 21:01:38.954 SERIAL « 0x010700134f000002a6 (9 bytes) 21:01:38.954 SERIAL » [ACK] (0x06) 21:01:38.954 DRIVER « [REQ] [SendData] callback id: 79 transmit status: OK 21:01:38.970 SERIAL « 0x010b000400200570060a0105ad (13 bytes) 21:01:38.971 CNTRLR [Node 032] [+] [Configuration] 10: 5 21:01:38.972 SERIAL » [ACK] (0x06) 21:01:38.972 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 5 21:01:38.973 CNTRLR « [Node 032] parameter #10 has value: 5 21:01:38.973 CNTRLR » [Node 032] querying parameter #11 value... 21:01:38.974 SERIAL » 0x010a0013200370050b2550ce (12 bytes) 21:01:38.974 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 80 └─[ConfigurationCCGet] parameter #: 11 21:01:38.975 SERIAL « [ACK] (0x06) 21:01:38.980 SERIAL « 0x0104011301e8 (6 bytes) 21:01:38.980 SERIAL » [ACK] (0x06) 21:01:38.981 DRIVER « [RES] [SendData] was sent: true 21:01:38.996 SERIAL « 0x0107001350000002b9 (9 bytes) 21:01:38.996 SERIAL » [ACK] (0x06) 21:01:38.997 DRIVER « [REQ] [SendData] callback id: 80 transmit status: OK 21:01:39.013 SERIAL « 0x010b000400200570060b0101a8 (13 bytes) 21:01:39.015 CNTRLR [Node 032] [+] [Configuration] 11: 1 21:01:39.015 SERIAL » [ACK] (0x06) 21:01:39.016 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 11 value size: 1 value: 1 21:01:39.018 CNTRLR « [Node 032] parameter #11 has value: 1 21:01:39.018 CNTRLR [Node 032] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 21:01:39.029 CNTRLR [Node 032] CentralSceneCC: doing a complete interview... 21:01:39.030 CNTRLR [Node 032] Error during node interview: Cannot create an instance of the unsup ported CC Association Group Information (0x59) 21:01:42.894 SERIAL « 0x010c0004001a063105042211da32 (14 bytes) 21:01:42.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:01:42.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 243.8 => 457 [Endpoint 0] 21:01:42.896 SERIAL » [ACK] (0x06) 21:01:42.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 457 21:01:46.894 SERIAL « 0x010c0004001a0631050422099666 (14 bytes) 21:01:46.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:01:46.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 457 => 245.4 [Endpoint 0] 21:01:46.896 SERIAL » [ACK] (0x06) 21:01:46.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 245.4 21:01:49.018 DRIVER The awake timeout for node 32 has elapsed. Assuming it is asleep. 21:01:49.018 CNTRLR [Node 032] The node is now asleep. 21:01:58.816 SERIAL « 0x010c0004001c0631050422028578 (14 bytes) 21:01:58.818 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:01:58.820 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 76.6 => 64.5 [Endpoint 0] 21:01:58.820 SERIAL » [ACK] (0x06) 21:01:58.822 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 64.5 21:02:02.815 SERIAL « 0x010c0004001c06310504220212ef (14 bytes) 21:02:02.816 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:02:02.817 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 64.5 => 53 [Endpoint 0] 21:02:02.817 SERIAL » [ACK] (0x06) 21:02:02.818 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 53 21:02:43.814 SERIAL « 0x010c0004001c0631050422028c71 (14 bytes) 21:02:43.815 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:02:43.816 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 53 => 65.2 [Endpoint 0] 21:02:43.816 SERIAL » [ACK] (0x06) 21:02:43.817 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 65.2 21:02:46.484 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 21:02:46.486 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 21:02:46.487 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 21:02:46.487 SERIAL » [ACK] (0x06) 21:02:46.488 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 21:02:54.814 SERIAL « 0x010c0004001c06310504220226db (14 bytes) 21:02:54.815 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:02:54.816 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 65.2 => 55 [Endpoint 0] 21:02:54.817 SERIAL » [ACK] (0x06) 21:02:54.818 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 55 21:03:09.814 SERIAL « 0x010c0004001c063105042202e71a (14 bytes) 21:03:09.815 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:03:09.816 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 55 => 74.3 [Endpoint 0] 21:03:09.816 SERIAL » [ACK] (0x06) 21:03:09.817 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 74.3 21:03:11.814 SERIAL « 0x010c0004001c06310504220236cb (14 bytes) 21:03:11.815 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:03:11.817 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 74.3 => 56.6 [Endpoint 0] 21:03:11.818 SERIAL » [ACK] (0x06) 21:03:11.819 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 56.6 21:03:12.814 SERIAL « 0x010c0004001c063105042201df21 (14 bytes) 21:03:12.815 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:03:12.816 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 56.6 => 47.9 [Endpoint 0] 21:03:12.817 SERIAL » [ACK] (0x06) 21:03:12.817 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 47.9 21:03:45.894 SERIAL « 0x010c0004001a063105042211ef07 (14 bytes) 21:03:45.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:03:45.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 245.4 => 459.1 [Endpoint 0] 21:03:45.897 SERIAL » [ACK] (0x06) 21:03:45.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 459.1 21:03:46.895 SERIAL « 0x010c0004001a06310504220931c1 (14 bytes) 21:03:46.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:03:46.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 459.1 => 235.3 [Endpoint 0] 21:03:46.897 SERIAL » [ACK] (0x06) 21:03:46.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 235.3 21:03:49.895 SERIAL « 0x010c0004001a063105042206d22d (14 bytes) 21:03:49.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:03:49.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 235.3 => 174.6 [Endpoint 0] 21:03:49.897 SERIAL » [ACK] (0x06) 21:03:49.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 174.6 21:03:52.895 SERIAL « 0x010c0004001a063105042207f608 (14 bytes) 21:03:52.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:03:52.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 174.6 => 203.8 [Endpoint 0] 21:03:52.897 SERIAL » [ACK] (0x06) 21:03:52.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 203.8 21:03:53.895 SERIAL « 0x010c0004001a063105042209d828 (14 bytes) 21:03:53.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:03:53.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 203.8 => 252 [Endpoint 0] 21:03:53.897 SERIAL » [ACK] (0x06) 21:03:53.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 252 21:03:54.895 SERIAL « 0x010c0004001a06310504220fbf49 (14 bytes) 21:03:54.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:03:54.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 252 => 403.1 [Endpoint 0] 21:03:54.897 SERIAL » [ACK] (0x06) 21:03:54.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 403.1 21:03:55.814 SERIAL « 0x010c0004001c0631050422025ea3 (14 bytes) 21:03:55.815 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:03:55.815 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 47.9 => 60.6 [Endpoint 0] 21:03:55.816 SERIAL » [ACK] (0x06) 21:03:55.817 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 60.6 21:03:59.814 SERIAL « 0x010c0004001c063105042201d729 (14 bytes) 21:03:59.815 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:03:59.815 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 60.6 => 47.1 [Endpoint 0] 21:03:59.816 SERIAL » [ACK] (0x06) 21:03:59.817 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 47.1 21:04:00.814 SERIAL « 0x010c0004001c06310504220226db (14 bytes) 21:04:00.815 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:04:00.815 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 47.1 => 55 [Endpoint 0] 21:04:00.816 SERIAL » [ACK] (0x06) 21:04:00.817 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 55 21:04:02.814 SERIAL « 0x010c0004001c063105042201a957 (14 bytes) 21:04:02.815 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:04:02.815 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 55 => 42.5 [Endpoint 0] 21:04:02.816 SERIAL » [ACK] (0x06) 21:04:02.817 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 42.5 21:04:16.894 SERIAL « 0x010c0004001a06310504220a5fac (14 bytes) 21:04:16.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:04:16.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 403.1 => 265.5 [Endpoint 0] 21:04:16.896 SERIAL » [ACK] (0x06) 21:04:16.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 265.5 21:04:22.805 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 21:04:22.806 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 21:04:22.807 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 21:04:22.807 SERIAL » [ACK] (0x06) 21:04:22.808 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 21:04:26.895 SERIAL « 0x010c0004001a063105042208c637 (14 bytes) 21:04:26.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:04:26.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 265.5 => 224.6 [Endpoint 0] 21:04:26.897 SERIAL » [ACK] (0x06) 21:04:26.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 224.6 21:04:27.895 SERIAL « 0x010c0004001a06310504220a58ab (14 bytes) 21:04:27.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:04:27.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 224.6 => 264.8 [Endpoint 0] 21:04:27.897 SERIAL » [ACK] (0x06) 21:04:27.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 264.8 21:04:29.894 SERIAL « 0x010c0004001a06310504220fb244 (14 bytes) 21:04:29.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:04:29.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 264.8 => 401.8 [Endpoint 0] 21:04:29.896 SERIAL » [ACK] (0x06) 21:04:29.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 401.8 21:04:30.895 SERIAL « 0x010c0004001a06310504220848b9 (14 bytes) 21:04:30.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:04:30.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 401.8 => 212 [Endpoint 0] 21:04:30.897 SERIAL » [ACK] (0x06) 21:04:30.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 212 21:04:33.894 SERIAL « 0x010c0004001a063105042210b851 (14 bytes) 21:04:33.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:04:33.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 212 => 428 [Endpoint 0] 21:04:33.896 SERIAL » [ACK] (0x06) 21:04:33.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 428 21:04:46.895 SERIAL « 0x010c0004001a06310504220b1be9 (14 bytes) 21:04:46.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:04:46.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 428 => 284.3 [Endpoint 0] 21:04:46.897 SERIAL » [ACK] (0x06) 21:04:46.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 284.3 21:05:06.447 SERIAL « 0x0110000400060a32022134000000000000c2 (18 bytes) 21:05:06.448 CNTRLR [Node 006] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 21:05:06.448 CNTRLR [Node 006] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 21:05:06.449 SERIAL » [ACK] (0x06) 21:05:06.450 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 21:05:06.491 SERIAL « 0x0109000400110380035a39 (11 bytes) 21:05:06.496 CNTRLR [Node 017] [~] [Battery] level: 90 => 90 [Endpoint 0] 21:05:06.497 CNTRLR [Node 017] [~] [Battery] isLow: false => false [Endpoint 0] 21:05:06.497 SERIAL » [ACK] (0x06) 21:05:06.499 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 90 is low: false 21:05:06.550 SERIAL « 0x010c000400110643030142076c88 (14 bytes) 21:05:06.551 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpoint[1]: 19 => 19 [Endpoint 0] 21:05:06.552 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 21:05:06.552 SERIAL » [ACK] (0x06) 21:05:06.553 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 21:05:06.605 SERIAL « 0x010a00040011044608007fd5 (12 bytes) 21:05:06.606 CNTRLR [Node 017] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 21:05:06.607 CNTRLR [Node 017] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 21:05:06.607 SERIAL » [ACK] (0x06) 21:05:06.609 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ClimateControlScheduleCCOverrideReport] override type: None override state: Unused 21:05:06.659 SERIAL « 0x01080004001102840763 (10 bytes) 21:05:06.659 SERIAL » [ACK] (0x06) 21:05:06.660 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 21:05:06.662 CNTRLR « [Node 017] received wakeup notification 21:05:06.662 CNTRLR [Node 017] The node is now awake. 21:05:06.664 CNTRLR [Node 017] expects some queries after wake up, so it shall receive 21:05:06.664 CNTRLR [Node 017] compat query "Battery"::get() 21:05:06.671 SERIAL » 0x0109001311028002255100 (11 bytes) 21:05:06.673 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 81 └─[BatteryCCGet] 21:05:06.678 SERIAL « [ACK] (0x06) 21:05:06.680 SERIAL « 0x0104011301e8 (6 bytes) 21:05:06.681 SERIAL » [ACK] (0x06) 21:05:06.681 DRIVER « [RES] [SendData] was sent: true 21:05:06.701 SERIAL « 0x0107001351000003b9 (9 bytes) 21:05:06.702 SERIAL » [ACK] (0x06) 21:05:06.702 DRIVER « [REQ] [SendData] callback id: 81 transmit status: OK 21:05:06.710 SERIAL « 0x0109000400110380035a39 (11 bytes) 21:05:06.711 CNTRLR [Node 017] [~] [Battery] level: 90 => 90 [Endpoint 0] 21:05:06.712 CNTRLR [Node 017] [~] [Battery] isLow: false => false [Endpoint 0] 21:05:06.712 SERIAL » [ACK] (0x06) 21:05:06.713 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 90 is low: false 21:05:06.717 CNTRLR [Node 017] API call successful 21:05:06.717 CNTRLR [Node 017] compat query "Thermostat Setpoint"::get(1) 21:05:06.722 SERIAL » 0x010a001311034302012552c3 (12 bytes) 21:05:06.722 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 82 └─[ThermostatSetpointCCGet] setpoint type: Heating 21:05:06.726 SERIAL « [ACK] (0x06) 21:05:06.728 SERIAL « 0x0104011301e8 (6 bytes) 21:05:06.728 SERIAL » [ACK] (0x06) 21:05:06.729 DRIVER « [RES] [SendData] was sent: true 21:05:06.743 SERIAL « 0x0107001352000002bb (9 bytes) 21:05:06.744 SERIAL » [ACK] (0x06) 21:05:06.744 DRIVER « [REQ] [SendData] callback id: 82 transmit status: OK 21:05:06.753 SERIAL « 0x010c000400110643030142076c88 (14 bytes) 21:05:06.754 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpoint[1]: 19 => 19 [Endpoint 0] 21:05:06.755 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 21:05:06.755 SERIAL » [ACK] (0x06) 21:05:06.756 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 21:05:06.758 CNTRLR [Node 017] API call successful 21:05:07.759 CNTRLR » [Node 017] Sending node back to sleep... 21:05:07.764 SERIAL » 0x010900131102840825530c (11 bytes) 21:05:07.764 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 83 └─[WakeUpCCNoMoreInformation] 21:05:07.765 SERIAL « [ACK] (0x06) 21:05:07.769 SERIAL « 0x0104011301e8 (6 bytes) 21:05:07.769 SERIAL » [ACK] (0x06) 21:05:07.769 DRIVER « [RES] [SendData] was sent: true 21:05:07.785 SERIAL « 0x0107001353000002ba (9 bytes) 21:05:07.785 SERIAL » [ACK] (0x06) 21:05:07.786 DRIVER « [REQ] [SendData] callback id: 83 transmit status: OK 21:05:07.787 CNTRLR [Node 017] The node is now asleep. 21:05:07.788 CNTRLR [Node 017] Node asleep 21:05:23.895 SERIAL « 0x010c0004001a06310504220d8a7e (14 bytes) 21:05:23.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:05:23.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 284.3 => 346.6 [Endpoint 0] 21:05:23.897 SERIAL » [ACK] (0x06) 21:05:23.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 346.6 21:05:24.895 SERIAL « 0x010c0004001a06310504220a9e6d (14 bytes) 21:05:24.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:05:24.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 346.6 => 271.8 [Endpoint 0] 21:05:24.897 SERIAL » [ACK] (0x06) 21:05:24.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 271.8 21:05:26.895 SERIAL « 0x010c0004001a06310504220fcb3d (14 bytes) 21:05:26.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:05:26.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 271.8 => 404.3 [Endpoint 0] 21:05:26.897 SERIAL » [ACK] (0x06) 21:05:26.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 404.3 21:05:27.895 SERIAL « 0x010c0004001a06310504220a986b (14 bytes) 21:05:27.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:05:27.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 404.3 => 271.2 [Endpoint 0] 21:05:27.897 SERIAL » [ACK] (0x06) 21:05:27.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 271.2 21:05:39.813 SERIAL « 0x010c0004001c063105042201ec12 (14 bytes) 21:05:39.814 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:05:39.814 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 42.5 => 49.2 [Endpoint 0] 21:05:39.815 SERIAL » [ACK] (0x06) 21:05:39.816 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 49.2 21:05:40.813 SERIAL « 0x010c0004001c063105042201926c (14 bytes) 21:05:40.814 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:05:40.814 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 49.2 => 40.2 [Endpoint 0] 21:05:40.815 SERIAL » [ACK] (0x06) 21:05:40.816 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 40.2 21:05:41.813 SERIAL « 0x010c0004001c063105042201e31d (14 bytes) 21:05:41.814 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:05:41.814 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 40.2 => 48.3 [Endpoint 0] 21:05:41.815 SERIAL » [ACK] (0x06) 21:05:41.816 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 48.3 21:05:41.895 SERIAL « 0x010c0004001a063105042205c539 (14 bytes) 21:05:41.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:05:41.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 271.2 => 147.7 [Endpoint 0] 21:05:41.897 SERIAL » [ACK] (0x06) 21:05:41.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 147.7 21:05:42.813 SERIAL « 0x010c0004001c06310504220344b8 (14 bytes) 21:05:42.814 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:05:42.814 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 48.3 => 83.6 [Endpoint 0] 21:05:42.815 SERIAL » [ACK] (0x06) 21:05:42.816 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 83.6 21:05:42.895 SERIAL « 0x010c0004001a0631050422131ef4 (14 bytes) 21:05:42.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:05:42.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 147.7 => 489.4 [Endpoint 0] 21:05:42.897 SERIAL » [ACK] (0x06) 21:05:42.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 489.4 21:05:43.813 SERIAL « 0x010c0004001c063105042205c53f (14 bytes) 21:05:43.814 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:05:43.814 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 83.6 => 147.7 [Endpoint 0] 21:05:43.815 SERIAL » [ACK] (0x06) 21:05:43.816 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 147.7 21:05:46.895 SERIAL « 0x010c0004001a06310504220a8f7c (14 bytes) 21:05:46.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:05:46.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 489.4 => 270.3 [Endpoint 0] 21:05:46.897 SERIAL » [ACK] (0x06) 21:05:46.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 270.3 21:05:50.828 SERIAL « 0x010c0004001c0631050422000bf4 (14 bytes) 21:05:50.829 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:05:50.829 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 147.7 => 1.1 [Endpoint 0] 21:05:50.830 SERIAL » [ACK] (0x06) 21:05:50.831 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.1 21:05:59.126 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 21:05:59.127 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 21:05:59.128 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 21:05:59.129 SERIAL » [ACK] (0x06) 21:05:59.130 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 21:06:03.616 SERIAL « 0x0110000400120a32022134000000000000d6 (18 bytes) 21:06:03.617 CNTRLR [Node 018] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 21:06:03.618 CNTRLR [Node 018] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 21:06:03.618 SERIAL » [ACK] (0x06) 21:06:03.620 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 21:06:07.812 SERIAL « 0x010c0004001c06310504220010ef (14 bytes) 21:06:07.813 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:07.814 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.1 => 1.6 [Endpoint 0] 21:06:07.814 SERIAL » [ACK] (0x06) 21:06:07.815 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.6 21:06:12.895 SERIAL « 0x010c0004001a06310504220637c8 (14 bytes) 21:06:12.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:12.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 270.3 => 159.1 [Endpoint 0] 21:06:12.897 SERIAL » [ACK] (0x06) 21:06:12.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 159.1 21:06:13.895 SERIAL « 0x010c0004001a063105042212d13a (14 bytes) 21:06:13.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:13.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 159.1 => 481.7 [Endpoint 0] 21:06:13.898 SERIAL » [ACK] (0x06) 21:06:13.899 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 481.7 21:06:14.895 SERIAL « 0x010c0004001a06310504220a788b (14 bytes) 21:06:14.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:14.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 481.7 => 268 [Endpoint 0] 21:06:14.897 SERIAL » [ACK] (0x06) 21:06:14.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 268 21:06:15.895 SERIAL « 0x010c0004001a0631050422085dac (14 bytes) 21:06:15.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:15.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 268 => 214.1 [Endpoint 0] 21:06:15.897 SERIAL » [ACK] (0x06) 21:06:15.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 214.1 21:06:16.895 SERIAL « 0x010c0004001a06310504220a6f9c (14 bytes) 21:06:16.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:16.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 214.1 => 267.1 [Endpoint 0] 21:06:16.897 SERIAL » [ACK] (0x06) 21:06:16.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 267.1 21:06:21.895 SERIAL « 0x010c0004001a063105042205b945 (14 bytes) 21:06:21.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:21.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 267.1 => 146.5 [Endpoint 0] 21:06:21.897 SERIAL » [ACK] (0x06) 21:06:21.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 146.5 21:06:22.812 SERIAL « 0x010c0004001c0631050422000df2 (14 bytes) 21:06:22.813 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:22.813 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.6 => 1.3 [Endpoint 0] 21:06:22.814 SERIAL » [ACK] (0x06) 21:06:22.814 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.3 21:06:22.894 SERIAL « 0x010c0004001a06310504220c7580 (14 bytes) 21:06:22.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:22.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 146.5 => 318.9 [Endpoint 0] 21:06:22.896 SERIAL » [ACK] (0x06) 21:06:22.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 318.9 21:06:23.895 SERIAL « 0x010c0004001a06310504220a5ead (14 bytes) 21:06:23.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:23.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 318.9 => 265.4 [Endpoint 0] 21:06:23.897 SERIAL » [ACK] (0x06) 21:06:23.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 265.4 21:06:24.895 SERIAL « 0x010c0004001a063105042205b64a (14 bytes) 21:06:24.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:24.897 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 265.4 => 146.2 [Endpoint 0] 21:06:24.897 SERIAL » [ACK] (0x06) 21:06:24.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 146.2 21:06:25.812 SERIAL « 0x010c0004001c06310504220011ee (14 bytes) 21:06:25.812 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:25.813 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.3 => 1.7 [Endpoint 0] 21:06:25.813 SERIAL » [ACK] (0x06) 21:06:25.813 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.7 21:06:26.895 SERIAL « 0x010c0004001a06310504220ea354 (14 bytes) 21:06:26.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:26.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 146.2 => 374.7 [Endpoint 0] 21:06:26.897 SERIAL » [ACK] (0x06) 21:06:26.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 374.7 21:06:27.812 SERIAL « 0x010c0004001c0631050422000ef1 (14 bytes) 21:06:27.813 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:27.814 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.7 => 1.4 [Endpoint 0] 21:06:27.814 SERIAL » [ACK] (0x06) 21:06:27.815 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.4 21:06:28.812 SERIAL « 0x010c0004001c06310504220011ee (14 bytes) 21:06:28.812 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:28.812 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.4 => 1.7 [Endpoint 0] 21:06:28.813 SERIAL » [ACK] (0x06) 21:06:28.813 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.7 21:06:39.812 SERIAL « 0x010c0004001c0631050422000bf4 (14 bytes) 21:06:39.813 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:39.813 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.7 => 1.1 [Endpoint 0] 21:06:39.814 SERIAL » [ACK] (0x06) 21:06:39.815 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.1 21:06:40.812 SERIAL « 0x010c0004001c0631050422000df2 (14 bytes) 21:06:40.813 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:40.813 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.1 => 1.3 [Endpoint 0] 21:06:40.814 SERIAL » [ACK] (0x06) 21:06:40.815 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.3 21:06:41.812 SERIAL « 0x010c0004001c06310504220012ed (14 bytes) 21:06:41.813 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:41.813 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.3 => 1.8 [Endpoint 0] 21:06:41.814 SERIAL » [ACK] (0x06) 21:06:41.815 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.8 21:06:46.895 SERIAL « 0x010c0004001a06310504220a7380 (14 bytes) 21:06:46.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:46.897 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 374.7 => 267.5 [Endpoint 0] 21:06:46.898 SERIAL » [ACK] (0x06) 21:06:46.899 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 267.5 21:06:47.812 SERIAL « 0x010c0004001c0631050422000ef1 (14 bytes) 21:06:47.813 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:47.813 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.8 => 1.4 [Endpoint 0] 21:06:47.814 SERIAL » [ACK] (0x06) 21:06:47.815 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.4 21:06:49.812 SERIAL « 0x010c0004001c06310504220012ed (14 bytes) 21:06:49.813 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:49.813 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.4 => 1.8 [Endpoint 0] 21:06:49.814 SERIAL » [ACK] (0x06) 21:06:49.815 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.8 21:06:49.995 SERIAL « 0x010c0004001a063105042204e01d (14 bytes) 21:06:49.996 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:49.996 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 267.5 => 124.8 [Endpoint 0] 21:06:49.997 SERIAL » [ACK] (0x06) 21:06:49.998 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 124.8 21:06:50.895 SERIAL « 0x010c0004001a06310504220628d7 (14 bytes) 21:06:50.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:50.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 124.8 => 157.6 [Endpoint 0] 21:06:50.897 SERIAL » [ACK] (0x06) 21:06:50.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 157.6 21:06:52.895 SERIAL « 0x010c0004001a063105042203fc06 (14 bytes) 21:06:52.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:52.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 157.6 => 102 [Endpoint 0] 21:06:52.897 SERIAL » [ACK] (0x06) 21:06:52.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 102 21:06:53.895 SERIAL « 0x010c0004001a06310504220a15e6 (14 bytes) 21:06:53.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:06:53.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 102 => 258.1 [Endpoint 0] 21:06:53.897 SERIAL » [ACK] (0x06) 21:06:53.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 258.1 21:07:10.812 SERIAL « 0x010c0004001c0631050422000ef1 (14 bytes) 21:07:10.813 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:07:10.813 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.8 => 1.4 [Endpoint 0] 21:07:10.814 SERIAL » [ACK] (0x06) 21:07:10.814 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.4 21:07:15.812 SERIAL « 0x010c0004001c06310504220011ee (14 bytes) 21:07:15.815 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:07:15.815 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.4 => 1.7 [Endpoint 0] 21:07:15.815 SERIAL » [ACK] (0x06) 21:07:15.816 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.7 21:07:16.895 SERIAL « 0x010c0004001a063105042203d12b (14 bytes) 21:07:16.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:07:16.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 258.1 => 97.7 [Endpoint 0] 21:07:16.897 SERIAL » [ACK] (0x06) 21:07:16.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 97.7 21:07:18.849 SERIAL « 0x010c0004001c0631050422000df2 (14 bytes) 21:07:18.850 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:07:18.850 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.7 => 1.3 [Endpoint 0] 21:07:18.851 SERIAL » [ACK] (0x06) 21:07:18.852 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.3 21:07:18.909 SERIAL « 0x010c0004001c0631050422000df2 (14 bytes) 21:07:18.910 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:07:18.911 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.3 => 1.3 [Endpoint 0] 21:07:18.911 SERIAL » [ACK] (0x06) 21:07:18.912 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.3 21:07:19.562 SERIAL « 0x010c0004001c0631050422000df2 (14 bytes) 21:07:19.563 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:07:19.564 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.3 => 1.3 [Endpoint 0] 21:07:19.564 SERIAL » [ACK] (0x06) 21:07:19.565 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.3 21:07:20.859 SERIAL « 0x010c0004001c0631050422000ff0 (14 bytes) 21:07:20.860 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:07:20.860 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.3 => 1.5 [Endpoint 0] 21:07:20.861 SERIAL » [ACK] (0x06) 21:07:20.862 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.5 21:07:32.894 SERIAL « 0x010c0004001a063105042206e718 (14 bytes) 21:07:32.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:07:32.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 97.7 => 176.7 [Endpoint 0] 21:07:32.896 SERIAL » [ACK] (0x06) 21:07:32.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 176.7 21:07:33.895 SERIAL « 0x010c0004001a0631050422036e94 (14 bytes) 21:07:33.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:07:33.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 176.7 => 87.8 [Endpoint 0] 21:07:33.897 SERIAL » [ACK] (0x06) 21:07:33.899 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 87.8 21:07:35.448 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 21:07:35.449 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 21:07:35.451 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 21:07:35.451 SERIAL » [ACK] (0x06) 21:07:35.452 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 21:07:45.859 SERIAL « 0x010c0004001c0631050422000cf3 (14 bytes) 21:07:45.860 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:07:45.860 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.5 => 1.2 [Endpoint 0] 21:07:45.861 SERIAL » [ACK] (0x06) 21:07:45.862 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.2 21:07:46.859 SERIAL « 0x010c0004001c0631050422000ef1 (14 bytes) 21:07:46.860 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:07:46.860 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.2 => 1.4 [Endpoint 0] 21:07:46.861 SERIAL » [ACK] (0x06) 21:07:46.862 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.4 21:07:48.859 SERIAL « 0x010c0004001c06310504220012ed (14 bytes) 21:07:48.860 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:07:48.860 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.4 => 1.8 [Endpoint 0] 21:07:48.861 SERIAL » [ACK] (0x06) 21:07:48.862 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.8 21:07:49.859 SERIAL « 0x010c0004001c0631050422000df2 (14 bytes) 21:07:49.860 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:07:49.860 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.8 => 1.3 [Endpoint 0] 21:07:49.861 SERIAL » [ACK] (0x06) 21:07:49.862 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.3 21:07:52.858 SERIAL « 0x010c0004001c0631050422000ff0 (14 bytes) 21:07:52.859 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:07:52.860 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.3 => 1.5 [Endpoint 0] 21:07:52.860 SERIAL » [ACK] (0x06) 21:07:52.861 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.5 21:08:08.858 SERIAL « 0x010c0004001c0631050422000cf3 (14 bytes) 21:08:08.859 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:08:08.860 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.5 => 1.2 [Endpoint 0] 21:08:08.860 SERIAL » [ACK] (0x06) 21:08:08.861 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.2 21:08:09.859 SERIAL « 0x010c0004001c06310504220011ee (14 bytes) 21:08:09.860 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:08:09.860 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.2 => 1.7 [Endpoint 0] 21:08:09.861 SERIAL » [ACK] (0x06) 21:08:09.862 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.7 21:08:10.859 SERIAL « 0x010c0004001c0631050422000ef1 (14 bytes) 21:08:10.859 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:08:10.860 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.7 => 1.4 [Endpoint 0] 21:08:10.860 SERIAL » [ACK] (0x06) 21:08:10.861 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.4 21:08:15.859 SERIAL « 0x010c0004001c06310504220011ee (14 bytes) 21:08:15.859 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:08:15.860 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.4 => 1.7 [Endpoint 0] 21:08:15.860 SERIAL » [ACK] (0x06) 21:08:15.863 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.7 21:08:18.859 SERIAL « 0x010c0004001c0631050422000ef1 (14 bytes) 21:08:18.859 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:08:18.860 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.7 => 1.4 [Endpoint 0] 21:08:18.860 SERIAL » [ACK] (0x06) 21:08:18.861 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.4 21:08:37.858 SERIAL « 0x010c0004001c06310504220011ee (14 bytes) 21:08:37.859 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:08:37.860 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.4 => 1.7 [Endpoint 0] 21:08:37.860 SERIAL » [ACK] (0x06) 21:08:37.861 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.7 21:08:41.858 SERIAL « 0x010c0004001c0631050422000ef1 (14 bytes) 21:08:41.859 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:08:41.860 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.7 => 1.4 [Endpoint 0] 21:08:41.860 SERIAL » [ACK] (0x06) 21:08:41.861 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.4 21:08:45.858 SERIAL « 0x010c0004001c06310504220011ee (14 bytes) 21:08:45.859 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:08:45.860 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.4 => 1.7 [Endpoint 0] 21:08:45.860 SERIAL » [ACK] (0x06) 21:08:45.861 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.7 21:08:46.858 SERIAL « 0x010c0004001c0631050422000ef1 (14 bytes) 21:08:46.859 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:08:46.860 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.7 => 1.4 [Endpoint 0] 21:08:46.860 SERIAL » [ACK] (0x06) 21:08:46.861 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.4 21:08:47.858 SERIAL « 0x010c0004001c06310504220011ee (14 bytes) 21:08:47.859 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:08:47.860 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.4 => 1.7 [Endpoint 0] 21:08:47.860 SERIAL » [ACK] (0x06) 21:08:47.861 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.7 21:09:08.858 SERIAL « 0x010c0004001c0631050422000cf3 (14 bytes) 21:09:08.859 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:09:08.859 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.7 => 1.2 [Endpoint 0] 21:09:08.860 SERIAL » [ACK] (0x06) 21:09:08.861 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.2 21:09:09.858 SERIAL « 0x010c0004001c0631050422000ef1 (14 bytes) 21:09:09.858 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:09:09.859 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.2 => 1.4 [Endpoint 0] 21:09:09.860 SERIAL » [ACK] (0x06) 21:09:09.860 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 1.4 21:09:11.769 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 21:09:11.770 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 21:09:11.771 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 21:09:11.772 SERIAL » [ACK] (0x06) 21:09:11.773 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 21:09:19.858 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:09:19.859 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:09:19.859 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 1.4 => 0.3 [Endpoint 0] 21:09:19.860 SERIAL » [ACK] (0x06) 21:09:19.861 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:09:21.858 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:09:21.858 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:09:21.859 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0.4 [Endpoint 0] 21:09:21.860 SERIAL » [ACK] (0x06) 21:09:21.860 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:09:33.858 SERIAL « 0x010c0004001c06310504220005fa (14 bytes) 21:09:33.859 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:09:33.859 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.5 [Endpoint 0] 21:09:33.860 SERIAL » [ACK] (0x06) 21:09:33.861 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.5 21:09:37.858 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:09:37.858 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:09:37.859 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.5 => 0.3 [Endpoint 0] 21:09:37.859 SERIAL » [ACK] (0x06) 21:09:37.860 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:09:38.858 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:09:38.859 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:09:38.859 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0.4 [Endpoint 0] 21:09:38.860 SERIAL » [ACK] (0x06) 21:09:38.861 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:09:40.858 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:09:40.858 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:09:40.859 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.3 [Endpoint 0] 21:09:40.859 SERIAL » [ACK] (0x06) 21:09:40.860 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:09:42.074 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:09:42.075 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:09:42.076 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0.4 [Endpoint 0] 21:09:42.076 SERIAL » [ACK] (0x06) 21:09:42.077 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:09:46.857 SERIAL « 0x010c0004001c06310504220000ff (14 bytes) 21:09:46.858 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:09:46.859 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0 [Endpoint 0] 21:09:46.859 SERIAL » [ACK] (0x06) 21:09:46.862 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 21:09:47.857 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:09:47.858 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:09:47.859 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0 => 0.4 [Endpoint 0] 21:09:47.861 SERIAL » [ACK] (0x06) 21:09:47.862 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:10:01.266 SERIAL « 0x0109000400110380035a39 (11 bytes) 21:10:01.267 CNTRLR [Node 017] [~] [Battery] level: 90 => 90 [Endpoint 0] 21:10:01.267 CNTRLR [Node 017] [~] [Battery] isLow: false => false [Endpoint 0] 21:10:01.268 SERIAL » [ACK] (0x06) 21:10:01.269 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 90 is low: false 21:10:01.323 SERIAL « 0x010c000400110643030142076c88 (14 bytes) 21:10:01.324 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpoint[1]: 19 => 19 [Endpoint 0] 21:10:01.325 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 21:10:01.325 SERIAL » [ACK] (0x06) 21:10:01.326 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 21:10:01.379 SERIAL « 0x010a00040011044608007fd5 (12 bytes) 21:10:01.380 CNTRLR [Node 017] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 21:10:01.381 CNTRLR [Node 017] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 21:10:01.381 SERIAL » [ACK] (0x06) 21:10:01.382 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ClimateControlScheduleCCOverrideReport] override type: None override state: Unused 21:10:01.433 SERIAL « 0x01080004001102840763 (10 bytes) 21:10:01.433 SERIAL » [ACK] (0x06) 21:10:01.434 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 21:10:01.436 CNTRLR « [Node 017] received wakeup notification 21:10:01.436 CNTRLR [Node 017] The node is now awake. 21:10:01.437 CNTRLR [Node 017] expects some queries after wake up, so it shall receive 21:10:01.437 CNTRLR [Node 017] compat query "Battery"::get() 21:10:01.439 SERIAL » 0x0109001311028002255405 (11 bytes) 21:10:01.439 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 84 └─[BatteryCCGet] 21:10:01.440 SERIAL « [ACK] (0x06) 21:10:01.444 SERIAL « 0x0104011301e8 (6 bytes) 21:10:01.444 SERIAL » [ACK] (0x06) 21:10:01.445 DRIVER « [RES] [SendData] was sent: true 21:10:01.475 SERIAL « 0x0107001354000003bc (9 bytes) 21:10:01.476 SERIAL » [ACK] (0x06) 21:10:01.476 DRIVER « [REQ] [SendData] callback id: 84 transmit status: OK 21:10:01.484 SERIAL « 0x0109000400110380035a39 (11 bytes) 21:10:01.485 CNTRLR [Node 017] [~] [Battery] level: 90 => 90 [Endpoint 0] 21:10:01.485 CNTRLR [Node 017] [~] [Battery] isLow: false => false [Endpoint 0] 21:10:01.486 SERIAL » [ACK] (0x06) 21:10:01.487 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 90 is low: false 21:10:01.488 CNTRLR [Node 017] API call successful 21:10:01.489 CNTRLR [Node 017] compat query "Thermostat Setpoint"::get(1) 21:10:01.494 SERIAL » 0x010a001311034302012555c4 (12 bytes) 21:10:01.495 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 85 └─[ThermostatSetpointCCGet] setpoint type: Heating 21:10:01.497 SERIAL « [ACK] (0x06) 21:10:01.500 SERIAL « 0x0104011301e8 (6 bytes) 21:10:01.500 SERIAL » [ACK] (0x06) 21:10:01.501 DRIVER « [RES] [SendData] was sent: true 21:10:01.516 SERIAL « 0x0107001355000002bc (9 bytes) 21:10:01.517 SERIAL » [ACK] (0x06) 21:10:01.517 DRIVER « [REQ] [SendData] callback id: 85 transmit status: OK 21:10:01.526 SERIAL « 0x010c000400110643030142076c88 (14 bytes) 21:10:01.526 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpoint[1]: 19 => 19 [Endpoint 0] 21:10:01.527 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 21:10:01.527 SERIAL » [ACK] (0x06) 21:10:01.528 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 21:10:01.530 CNTRLR [Node 017] API call successful 21:10:02.531 CNTRLR » [Node 017] Sending node back to sleep... 21:10:02.540 SERIAL » 0x0109001311028408255609 (11 bytes) 21:10:02.541 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 86 └─[WakeUpCCNoMoreInformation] 21:10:02.542 SERIAL « [ACK] (0x06) 21:10:02.546 SERIAL « 0x0104011301e8 (6 bytes) 21:10:02.546 SERIAL » [ACK] (0x06) 21:10:02.546 DRIVER « [RES] [SendData] was sent: true 21:10:02.561 SERIAL « 0x0107001356000002bf (9 bytes) 21:10:02.562 SERIAL » [ACK] (0x06) 21:10:02.562 DRIVER « [REQ] [SendData] callback id: 86 transmit status: OK 21:10:02.565 CNTRLR [Node 017] The node is now asleep. 21:10:02.565 CNTRLR [Node 017] Node asleep 21:10:07.857 SERIAL « 0x010c0004001c06310504220005fa (14 bytes) 21:10:07.858 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:10:07.859 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.5 [Endpoint 0] 21:10:07.859 SERIAL » [ACK] (0x06) 21:10:07.860 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.5 21:10:08.857 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:10:08.858 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:10:08.859 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.5 => 0.4 [Endpoint 0] 21:10:08.859 SERIAL » [ACK] (0x06) 21:10:08.860 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:10:10.857 SERIAL « 0x010c0004001c06310504220005fa (14 bytes) 21:10:10.858 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:10:10.859 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.5 [Endpoint 0] 21:10:10.859 SERIAL » [ACK] (0x06) 21:10:10.860 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.5 21:10:14.857 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:10:14.858 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:10:14.859 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.5 => 0.4 [Endpoint 0] 21:10:14.859 SERIAL » [ACK] (0x06) 21:10:14.860 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:10:17.857 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:10:17.858 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:10:17.859 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.3 [Endpoint 0] 21:10:17.859 SERIAL » [ACK] (0x06) 21:10:17.860 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:10:20.857 SERIAL « 0x010c0004001c06310504220000ff (14 bytes) 21:10:20.858 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:10:20.858 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0 [Endpoint 0] 21:10:20.859 SERIAL » [ACK] (0x06) 21:10:20.860 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 21:10:21.857 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:10:21.858 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:10:21.858 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0 => 0.3 [Endpoint 0] 21:10:21.859 SERIAL » [ACK] (0x06) 21:10:21.860 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:10:29.646 SERIAL « 0x0110000400060a32022134000000000000c2 (18 bytes) 21:10:29.647 CNTRLR [Node 006] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 21:10:29.648 CNTRLR [Node 006] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 21:10:29.649 SERIAL » [ACK] (0x06) 21:10:29.650 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 21:10:38.857 SERIAL « 0x010c0004001c06310504220005fa (14 bytes) 21:10:38.858 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:10:38.858 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0.5 [Endpoint 0] 21:10:38.859 SERIAL » [ACK] (0x06) 21:10:38.860 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.5 21:10:39.857 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:10:39.858 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:10:39.858 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.5 => 0.4 [Endpoint 0] 21:10:39.859 SERIAL » [ACK] (0x06) 21:10:39.860 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:10:41.857 SERIAL « 0x010c0004001c06310504220000ff (14 bytes) 21:10:41.858 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:10:41.858 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0 [Endpoint 0] 21:10:41.859 SERIAL » [ACK] (0x06) 21:10:41.860 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 21:10:42.857 SERIAL « 0x010c0004001c06310504220005fa (14 bytes) 21:10:42.858 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:10:42.858 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0 => 0.5 [Endpoint 0] 21:10:42.859 SERIAL » [ACK] (0x06) 21:10:42.860 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.5 21:10:43.857 SERIAL « 0x010c0004001c06310504220000ff (14 bytes) 21:10:43.858 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:10:43.858 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.5 => 0 [Endpoint 0] 21:10:43.859 SERIAL » [ACK] (0x06) 21:10:43.860 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 21:10:44.857 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:10:44.857 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:10:44.858 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0 => 0.3 [Endpoint 0] 21:10:44.858 SERIAL » [ACK] (0x06) 21:10:44.859 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:10:48.091 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 21:10:48.092 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 21:10:48.093 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 21:10:48.094 SERIAL » [ACK] (0x06) 21:10:48.095 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 21:10:55.857 SERIAL « 0x010c0004001c06310504220000ff (14 bytes) 21:10:55.858 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:10:55.858 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0 [Endpoint 0] 21:10:55.859 SERIAL » [ACK] (0x06) 21:10:55.860 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 21:10:56.856 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:10:56.857 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:10:56.858 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0 => 0.4 [Endpoint 0] 21:10:56.858 SERIAL » [ACK] (0x06) 21:10:56.859 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:10:56.896 SERIAL « 0x010c0004001a063105042206be41 (14 bytes) 21:10:56.897 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:10:56.897 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 87.8 => 172.6 [Endpoint 0] 21:10:56.898 SERIAL » [ACK] (0x06) 21:10:56.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 172.6 21:10:56.961 SERIAL « 0x010c0004001a063105042206be41 (14 bytes) 21:10:56.962 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:10:56.963 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 172.6 => 172.6 [Endpoint 0] 21:10:56.963 SERIAL » [ACK] (0x06) 21:10:56.964 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 172.6 21:10:57.895 SERIAL « 0x010c0004001a06310504220352a8 (14 bytes) 21:10:57.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:10:57.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 172.6 => 85 [Endpoint 0] 21:10:57.897 SERIAL » [ACK] (0x06) 21:10:57.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 85 21:11:08.856 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:11:08.857 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:11:08.858 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.3 [Endpoint 0] 21:11:08.858 SERIAL » [ACK] (0x06) 21:11:08.859 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:11:10.857 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:11:10.857 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:11:10.858 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0.4 [Endpoint 0] 21:11:10.859 SERIAL » [ACK] (0x06) 21:11:10.860 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:11:11.857 SERIAL « 0x010c0004001c06310504220005fa (14 bytes) 21:11:11.857 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:11:11.858 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.5 [Endpoint 0] 21:11:11.858 SERIAL » [ACK] (0x06) 21:11:11.859 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.5 21:11:13.048 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:11:13.049 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:11:13.050 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.5 => 0.4 [Endpoint 0] 21:11:13.050 SERIAL » [ACK] (0x06) 21:11:13.051 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:11:16.856 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:11:16.857 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:11:16.858 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.3 [Endpoint 0] 21:11:16.858 SERIAL » [ACK] (0x06) 21:11:16.859 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:11:26.816 SERIAL « 0x0110000400120a32022134000000000000d6 (18 bytes) 21:11:26.817 CNTRLR [Node 018] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 21:11:26.818 CNTRLR [Node 018] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 21:11:26.818 SERIAL » [ACK] (0x06) 21:11:26.819 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 21:11:37.856 SERIAL « 0x010c0004001c06310504220005fa (14 bytes) 21:11:37.857 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:11:37.858 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0.5 [Endpoint 0] 21:11:37.858 SERIAL » [ACK] (0x06) 21:11:37.859 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.5 21:11:38.856 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:11:38.857 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:11:38.858 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.5 => 0.3 [Endpoint 0] 21:11:38.858 SERIAL » [ACK] (0x06) 21:11:38.859 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:11:38.896 SERIAL « 0x010c0004001a0631050422066b94 (14 bytes) 21:11:38.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:11:38.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 85 => 164.3 [Endpoint 0] 21:11:38.897 SERIAL » [ACK] (0x06) 21:11:38.897 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 164.3 21:11:38.963 SERIAL « 0x010c0004001a0631050422066b94 (14 bytes) 21:11:38.963 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:11:38.964 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 164.3 => 164.3 [Endpoint 0] 21:11:38.964 SERIAL » [ACK] (0x06) 21:11:38.965 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 164.3 21:11:39.856 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:11:39.858 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:11:39.859 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0.4 [Endpoint 0] 21:11:39.860 SERIAL » [ACK] (0x06) 21:11:39.860 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:11:39.896 SERIAL « 0x010c0004001a0631050422035ba1 (14 bytes) 21:11:39.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:11:39.897 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 164.3 => 85.9 [Endpoint 0] 21:11:39.897 SERIAL » [ACK] (0x06) 21:11:39.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 85.9 21:11:39.931 SERIAL « 0x010c0004001a0631050422035ba1 (14 bytes) 21:11:39.932 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:11:39.933 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 85.9 => 85.9 [Endpoint 0] 21:11:39.933 SERIAL » [ACK] (0x06) 21:11:39.934 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 85.9 21:11:40.014 SERIAL « 0x010c0004001a0631050422035ba1 (14 bytes) 21:11:40.015 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:11:40.015 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 85.9 => 85.9 [Endpoint 0] 21:11:40.016 SERIAL » [ACK] (0x06) 21:11:40.017 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 85.9 21:11:40.856 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:11:40.857 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:11:40.858 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.3 [Endpoint 0] 21:11:40.858 SERIAL » [ACK] (0x06) 21:11:40.859 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:11:41.856 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:11:41.857 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:11:41.858 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0.4 [Endpoint 0] 21:11:41.858 SERIAL » [ACK] (0x06) 21:11:41.859 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:12:01.856 SERIAL « 0x010c0004001c06310504220000ff (14 bytes) 21:12:01.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:12:01.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0 [Endpoint 0] 21:12:01.858 SERIAL » [ACK] (0x06) 21:12:01.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 21:12:02.856 SERIAL « 0x010c0004001c06310504220005fa (14 bytes) 21:12:02.857 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:12:02.858 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0 => 0.5 [Endpoint 0] 21:12:02.858 SERIAL » [ACK] (0x06) 21:12:02.859 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.5 21:12:05.895 SERIAL « 0x010c0004001a063105042203f309 (14 bytes) 21:12:05.895 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:12:05.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 85.9 => 101.1 [Endpoint 0] 21:12:05.896 SERIAL » [ACK] (0x06) 21:12:05.896 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 101.1 21:12:07.856 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:12:07.857 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:12:07.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.5 => 0.3 [Endpoint 0] 21:12:07.858 SERIAL » [ACK] (0x06) 21:12:07.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:12:08.856 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:12:08.857 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:12:08.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0.4 [Endpoint 0] 21:12:08.858 SERIAL » [ACK] (0x06) 21:12:08.859 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:12:09.856 SERIAL « 0x010c0004001c06310504220005fa (14 bytes) 21:12:09.857 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:12:09.858 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.5 [Endpoint 0] 21:12:09.858 SERIAL » [ACK] (0x06) 21:12:09.859 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.5 21:12:10.856 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:12:10.857 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:12:10.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.5 => 0.4 [Endpoint 0] 21:12:10.858 SERIAL » [ACK] (0x06) 21:12:10.859 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:12:13.856 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:12:13.857 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:12:13.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.3 [Endpoint 0] 21:12:13.858 SERIAL » [ACK] (0x06) 21:12:13.859 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:12:24.412 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 21:12:24.413 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 21:12:24.414 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 21:12:24.414 SERIAL » [ACK] (0x06) 21:12:24.415 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 21:12:24.895 SERIAL « 0x010c0004001a06310504220329d3 (14 bytes) 21:12:24.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:12:24.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 101.1 => 80.9 [Endpoint 0] 21:12:24.897 SERIAL » [ACK] (0x06) 21:12:24.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 80.9 21:12:28.895 SERIAL « 0x010c0004001a063105042203b349 (14 bytes) 21:12:28.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:12:28.896 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 80.9 => 94.7 [Endpoint 0] 21:12:28.897 SERIAL » [ACK] (0x06) 21:12:28.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 94.7 21:12:39.855 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:12:39.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:12:39.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0.4 [Endpoint 0] 21:12:39.857 SERIAL » [ACK] (0x06) 21:12:39.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:12:40.855 SERIAL « 0x010c0004001c06310504220005fa (14 bytes) 21:12:40.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:12:40.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.5 [Endpoint 0] 21:12:40.857 SERIAL » [ACK] (0x06) 21:12:40.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.5 21:12:41.855 SERIAL « 0x010c0004001c06310504220000ff (14 bytes) 21:12:41.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:12:41.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.5 => 0 [Endpoint 0] 21:12:41.857 SERIAL » [ACK] (0x06) 21:12:41.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 21:12:42.855 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:12:42.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:12:42.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0 => 0.3 [Endpoint 0] 21:12:42.857 SERIAL » [ACK] (0x06) 21:12:42.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:12:43.856 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:12:43.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:12:43.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0.4 [Endpoint 0] 21:12:43.857 SERIAL » [ACK] (0x06) 21:12:43.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:13:03.896 SERIAL « 0x010c0004001a063105042206c53a (14 bytes) 21:13:03.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:13:03.897 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 94.7 => 173.3 [Endpoint 0] 21:13:03.897 SERIAL » [ACK] (0x06) 21:13:03.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 173.3 21:13:04.896 SERIAL « 0x010c0004001a0631050422035ea4 (14 bytes) 21:13:04.897 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:13:04.897 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 173.3 => 86.2 [Endpoint 0] 21:13:04.898 SERIAL » [ACK] (0x06) 21:13:04.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 86.2 21:13:08.855 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:13:08.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:13:08.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.3 [Endpoint 0] 21:13:08.857 SERIAL » [ACK] (0x06) 21:13:08.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:13:09.855 SERIAL « 0x010c0004001c06310504220005fa (14 bytes) 21:13:09.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:13:09.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0.5 [Endpoint 0] 21:13:09.857 SERIAL » [ACK] (0x06) 21:13:09.859 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.5 21:13:10.855 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:13:10.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:13:10.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.5 => 0.4 [Endpoint 0] 21:13:10.857 SERIAL » [ACK] (0x06) 21:13:10.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:13:17.855 SERIAL « 0x010c0004001c06310504220005fa (14 bytes) 21:13:17.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:13:17.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.5 [Endpoint 0] 21:13:17.857 SERIAL » [ACK] (0x06) 21:13:17.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.5 21:13:18.856 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:13:18.857 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:13:18.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.5 => 0.4 [Endpoint 0] 21:13:18.858 SERIAL » [ACK] (0x06) 21:13:18.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:13:37.856 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:13:37.857 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:13:37.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.3 [Endpoint 0] 21:13:37.858 SERIAL » [ACK] (0x06) 21:13:37.859 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:13:42.856 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:13:42.859 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:13:42.860 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0.4 [Endpoint 0] 21:13:42.860 SERIAL » [ACK] (0x06) 21:13:42.861 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:13:43.856 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:13:43.857 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:13:43.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.3 [Endpoint 0] 21:13:43.858 SERIAL » [ACK] (0x06) 21:13:43.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:13:45.856 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:13:45.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:13:45.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0.4 [Endpoint 0] 21:13:45.857 SERIAL » [ACK] (0x06) 21:13:45.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:13:48.856 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:13:48.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:13:48.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.3 [Endpoint 0] 21:13:48.857 SERIAL » [ACK] (0x06) 21:13:48.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:14:00.734 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 21:14:00.735 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 21:14:00.736 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 21:14:00.736 SERIAL » [ACK] (0x06) 21:14:00.737 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 21:14:04.896 SERIAL « 0x010c0004001a063105042203eb11 (14 bytes) 21:14:04.897 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:14:04.897 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 86.2 => 100.3 [Endpoint 0] 21:14:04.898 SERIAL » [ACK] (0x06) 21:14:04.899 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 100.3 21:14:07.855 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:14:07.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:14:07.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0.4 [Endpoint 0] 21:14:07.857 SERIAL » [ACK] (0x06) 21:14:07.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:14:12.967 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:14:12.968 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:14:12.968 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.3 [Endpoint 0] 21:14:12.969 SERIAL » [ACK] (0x06) 21:14:12.970 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:14:13.855 SERIAL « 0x010c0004001c06310504220000ff (14 bytes) 21:14:13.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:14:13.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0 [Endpoint 0] 21:14:13.857 SERIAL » [ACK] (0x06) 21:14:13.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 21:14:14.856 SERIAL « 0x010c0004001c06310504220005fa (14 bytes) 21:14:14.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:14:14.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0 => 0.5 [Endpoint 0] 21:14:14.858 SERIAL » [ACK] (0x06) 21:14:14.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.5 21:14:17.855 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:14:17.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:14:17.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.5 => 0.3 [Endpoint 0] 21:14:17.857 SERIAL » [ACK] (0x06) 21:14:17.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:14:25.896 SERIAL « 0x010c0004001a06310504220333c9 (14 bytes) 21:14:25.897 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:14:25.897 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 100.3 => 81.9 [Endpoint 0] 21:14:25.898 SERIAL » [ACK] (0x06) 21:14:25.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 81.9 21:14:29.896 SERIAL « 0x010c0004001a063105042203b04a (14 bytes) 21:14:29.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:14:29.897 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 81.9 => 94.4 [Endpoint 0] 21:14:29.897 SERIAL » [ACK] (0x06) 21:14:29.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 94.4 21:14:37.855 SERIAL « 0x010c0004001c06310504220005fa (14 bytes) 21:14:37.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:14:37.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0.5 [Endpoint 0] 21:14:37.857 SERIAL » [ACK] (0x06) 21:14:37.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.5 21:14:38.855 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:14:38.857 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:14:38.858 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.5 => 0.3 [Endpoint 0] 21:14:38.858 SERIAL » [ACK] (0x06) 21:14:38.859 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:14:39.855 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:14:39.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:14:39.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0.4 [Endpoint 0] 21:14:39.857 SERIAL » [ACK] (0x06) 21:14:39.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:14:40.855 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:14:40.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:14:40.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.3 [Endpoint 0] 21:14:40.857 SERIAL » [ACK] (0x06) 21:14:40.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:14:41.855 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:14:41.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:14:41.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0.4 [Endpoint 0] 21:14:41.857 SERIAL » [ACK] (0x06) 21:14:41.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:14:56.058 SERIAL « 0x0109000400110380035a39 (11 bytes) 21:14:56.061 CNTRLR [Node 017] [~] [Battery] level: 90 => 90 [Endpoint 0] 21:14:56.061 CNTRLR [Node 017] [~] [Battery] isLow: false => false [Endpoint 0] 21:14:56.062 SERIAL » [ACK] (0x06) 21:14:56.063 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 90 is low: false 21:14:56.116 SERIAL « 0x010c000400110643030142076c88 (14 bytes) 21:14:56.117 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpoint[1]: 19 => 19 [Endpoint 0] 21:14:56.117 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 21:14:56.118 SERIAL » [ACK] (0x06) 21:14:56.118 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 21:14:56.170 SERIAL « 0x010a00040011044608007fd5 (12 bytes) 21:14:56.171 CNTRLR [Node 017] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 21:14:56.172 CNTRLR [Node 017] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 21:14:56.172 SERIAL » [ACK] (0x06) 21:14:56.173 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ClimateControlScheduleCCOverrideReport] override type: None override state: Unused 21:14:56.226 SERIAL « 0x01080004001102840763 (10 bytes) 21:14:56.227 SERIAL » [ACK] (0x06) 21:14:56.227 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 21:14:56.228 CNTRLR « [Node 017] received wakeup notification 21:14:56.229 CNTRLR [Node 017] The node is now awake. 21:14:56.230 CNTRLR [Node 017] expects some queries after wake up, so it shall receive 21:14:56.230 CNTRLR [Node 017] compat query "Battery"::get() 21:14:56.236 SERIAL » 0x0109001311028002255706 (11 bytes) 21:14:56.237 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 87 └─[BatteryCCGet] 21:14:56.238 SERIAL « [ACK] (0x06) 21:14:56.242 SERIAL « 0x0104011301e8 (6 bytes) 21:14:56.243 SERIAL » [ACK] (0x06) 21:14:56.243 DRIVER « [RES] [SendData] was sent: true 21:14:56.268 SERIAL « 0x0107001357000003bf (9 bytes) 21:14:56.269 SERIAL » [ACK] (0x06) 21:14:56.269 DRIVER « [REQ] [SendData] callback id: 87 transmit status: OK 21:14:56.277 SERIAL « 0x0109000400110380035a39 (11 bytes) 21:14:56.278 CNTRLR [Node 017] [~] [Battery] level: 90 => 90 [Endpoint 0] 21:14:56.278 CNTRLR [Node 017] [~] [Battery] isLow: false => false [Endpoint 0] 21:14:56.279 SERIAL » [ACK] (0x06) 21:14:56.280 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 90 is low: false 21:14:56.281 CNTRLR [Node 017] API call successful 21:14:56.281 CNTRLR [Node 017] compat query "Thermostat Setpoint"::get(1) 21:14:56.285 SERIAL » 0x010a001311034302012558c9 (12 bytes) 21:14:56.285 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 88 └─[ThermostatSetpointCCGet] setpoint type: Heating 21:14:56.288 SERIAL « [ACK] (0x06) 21:14:56.291 SERIAL « 0x0104011301e8 (6 bytes) 21:14:56.292 SERIAL » [ACK] (0x06) 21:14:56.292 DRIVER « [RES] [SendData] was sent: true 21:14:56.307 SERIAL « 0x0107001358000002b1 (9 bytes) 21:14:56.308 SERIAL » [ACK] (0x06) 21:14:56.311 DRIVER « [REQ] [SendData] callback id: 88 transmit status: OK 21:14:56.317 SERIAL « 0x010c000400110643030142076c88 (14 bytes) 21:14:56.318 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpoint[1]: 19 => 19 [Endpoint 0] 21:14:56.318 CNTRLR [Node 017] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 21:14:56.318 SERIAL » [ACK] (0x06) 21:14:56.319 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 19 °C 21:14:56.321 CNTRLR [Node 017] API call successful 21:14:57.322 CNTRLR » [Node 017] Sending node back to sleep... 21:14:57.326 SERIAL » 0x0109001311028408255906 (11 bytes) 21:14:57.326 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 89 └─[WakeUpCCNoMoreInformation] 21:14:57.327 SERIAL « [ACK] (0x06) 21:14:57.331 SERIAL « 0x0104011301e8 (6 bytes) 21:14:57.331 SERIAL » [ACK] (0x06) 21:14:57.332 DRIVER « [RES] [SendData] was sent: true 21:14:57.347 SERIAL « 0x0107001359000002b0 (9 bytes) 21:14:57.348 SERIAL » [ACK] (0x06) 21:14:57.348 DRIVER « [REQ] [SendData] callback id: 89 transmit status: OK 21:14:57.350 CNTRLR [Node 017] The node is now asleep. 21:14:57.351 CNTRLR [Node 017] Node asleep 21:15:02.855 SERIAL « 0x010c0004001c06310504220000ff (14 bytes) 21:15:02.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:15:02.856 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0 [Endpoint 0] 21:15:02.857 SERIAL » [ACK] (0x06) 21:15:02.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 21:15:03.855 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:15:03.855 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:15:03.856 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0 => 0.4 [Endpoint 0] 21:15:03.856 SERIAL » [ACK] (0x06) 21:15:03.857 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:15:07.855 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:15:07.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:15:07.857 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.3 [Endpoint 0] 21:15:07.857 SERIAL » [ACK] (0x06) 21:15:07.858 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:15:08.855 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:15:08.855 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:15:08.856 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0.4 [Endpoint 0] 21:15:08.856 SERIAL » [ACK] (0x06) 21:15:08.857 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:15:09.855 SERIAL « 0x010c0004001c06310504220005fa (14 bytes) 21:15:09.856 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:15:09.856 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.5 [Endpoint 0] 21:15:09.857 SERIAL » [ACK] (0x06) 21:15:09.857 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.5 21:15:10.855 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:15:10.855 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:15:10.856 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.5 => 0.4 [Endpoint 0] 21:15:10.856 SERIAL » [ACK] (0x06) 21:15:10.857 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:15:11.854 SERIAL « 0x010c0004001c06310504220005fa (14 bytes) 21:15:11.855 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:15:11.856 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.5 [Endpoint 0] 21:15:11.856 SERIAL » [ACK] (0x06) 21:15:11.857 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.5 21:15:37.055 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 21:15:37.059 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 21:15:37.060 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 21:15:37.060 SERIAL » [ACK] (0x06) 21:15:37.061 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 21:15:38.855 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:15:38.855 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:15:38.856 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.5 => 0.4 [Endpoint 0] 21:15:38.856 SERIAL » [ACK] (0x06) 21:15:38.857 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:15:44.854 SERIAL « 0x010c0004001c06310504220005fa (14 bytes) 21:15:44.855 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:15:44.856 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.5 [Endpoint 0] 21:15:44.856 SERIAL » [ACK] (0x06) 21:15:44.857 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.5 21:15:45.854 SERIAL « 0x010c0004001c06310504220003fc (14 bytes) 21:15:45.855 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:15:45.856 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.5 => 0.3 [Endpoint 0] 21:15:45.856 SERIAL » [ACK] (0x06) 21:15:45.857 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.3 21:15:46.854 SERIAL « 0x010c0004001c06310504220004fb (14 bytes) 21:15:46.854 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:15:46.854 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.3 => 0.4 [Endpoint 0] 21:15:46.855 SERIAL » [ACK] (0x06) 21:15:46.855 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.4 21:15:50.840 SERIAL » 0x010a00131c03250100255aa2 (12 bytes) 21:15:50.840 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 90 └─[BinarySwitchCCSet] target value: false 21:15:50.841 SERIAL « [ACK] (0x06) 21:15:50.845 SERIAL « 0x0104011301e8 (6 bytes) 21:15:50.845 SERIAL » [ACK] (0x06) 21:15:50.846 DRIVER « [RES] [SendData] was sent: true 21:15:50.854 SERIAL « 0x010c0004001c06310504220005fa (14 bytes) 21:15:50.855 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:15:50.856 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.4 => 0.5 [Endpoint 0] 21:15:50.856 SERIAL » [ACK] (0x06) 21:15:50.857 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0.5 21:15:51.354 SERIAL « 0x010700135a00003382 (9 bytes) 21:15:51.354 SERIAL » [ACK] (0x06) 21:15:51.355 DRIVER « [REQ] [SendData] callback id: 90 transmit status: OK 21:15:51.361 SERIAL » 0x010900131c022502255ba2 (11 bytes) 21:15:51.361 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 91 └─[BinarySwitchCCGet] 21:15:51.362 SERIAL « [ACK] (0x06) 21:15:51.368 SERIAL « 0x0104011301e8 (6 bytes) 21:15:51.368 SERIAL » [ACK] (0x06) 21:15:51.368 DRIVER « [RES] [SendData] was sent: true 21:15:51.532 SERIAL « 0x01090004001c03250300cb (11 bytes) 21:15:51.533 CNTRLR [Node 028] [~] [Binary Switch] currentValue: true => false [Endpoint 0] 21:15:51.534 SERIAL » [ACK] (0x06) 21:15:51.535 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 21:15:51.548 SERIAL « 0x010700135b000013a3 (9 bytes) 21:15:51.548 SERIAL » [ACK] (0x06) 21:15:51.549 DRIVER « [REQ] [SendData] callback id: 91 transmit status: OK 21:15:52.160 SERIAL « 0x010c0004001c06310504220000ff (14 bytes) 21:15:52.161 CNTRLR [Node 028] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:15:52.162 CNTRLR [Node 028] [~] [Multilevel Sensor] Power: 0.5 => 0 [Endpoint 0] 21:15:52.164 SERIAL » [ACK] (0x06) 21:15:52.165 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 21:15:52.846 SERIAL « 0x0110000400060a32022134000000000000c2 (18 bytes) 21:15:52.847 CNTRLR [Node 006] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 21:15:52.848 CNTRLR [Node 006] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 21:15:52.848 SERIAL » [ACK] (0x06) 21:15:52.850 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 21:15:53.153 CNTRLR [Node 028] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 21:15:53.656 SERIAL » 0x010900131c022502255ba2 (11 bytes) 21:15:53.657 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 91 └─[BinarySwitchCCGet] 21:15:53.658 SERIAL « [ACK] (0x06) 21:15:53.662 SERIAL « 0x0104011301e8 (6 bytes) 21:15:53.662 SERIAL » [ACK] (0x06) 21:15:53.662 DRIVER « [RES] [SendData] was sent: true 21:15:53.801 SERIAL « 0x010700135b00000ebe (9 bytes) 21:15:53.802 SERIAL » [ACK] (0x06) 21:15:53.802 DRIVER « [REQ] [SendData] callback id: 91 transmit status: OK 21:15:53.923 SERIAL « 0x01090004001c03250300cb (11 bytes) 21:15:53.924 CNTRLR [Node 028] [~] [Binary Switch] currentValue: false => false [Endpoint 0] 21:15:53.924 SERIAL » [ACK] (0x06) 21:15:53.925 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 21:15:56.896 SERIAL « 0x010c0004001a063105042207906e (14 bytes) 21:15:56.897 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:15:56.897 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 94.4 => 193.6 [Endpoint 0] 21:15:56.897 SERIAL » [ACK] (0x06) 21:15:56.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 193.6 21:15:57.896 SERIAL « 0x010c0004001a0631050422037a80 (14 bytes) 21:15:57.897 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:15:57.897 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 193.6 => 89 [Endpoint 0] 21:15:57.898 SERIAL » [ACK] (0x06) 21:15:57.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 89 21:16:34.896 SERIAL « 0x010c0004001a0631050422040af7 (14 bytes) 21:16:34.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:16:34.899 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 89 => 103.4 [Endpoint 0] 21:16:34.900 SERIAL » [ACK] (0x06) 21:16:34.901 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 103.4 21:16:50.016 SERIAL « 0x0110000400120a32022134000000000000d6 (18 bytes) 21:16:50.016 CNTRLR [Node 018] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 21:16:50.017 CNTRLR [Node 018] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 21:16:50.018 SERIAL » [ACK] (0x06) 21:16:50.019 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 21:16:51.896 SERIAL « 0x010c0004001a0631050422036c96 (14 bytes) 21:16:51.896 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:16:51.897 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 103.4 => 87.6 [Endpoint 0] 21:16:51.898 SERIAL » [ACK] (0x06) 21:16:51.898 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 87.6 21:16:51.918 SERIAL « 0x010c0004001a0631050422036c96 (14 bytes) 21:16:51.918 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:16:51.919 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 87.6 => 87.6 [Endpoint 0] 21:16:51.920 SERIAL » [ACK] (0x06) 21:16:51.920 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 87.6 21:17:13.377 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 21:17:13.377 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 21:17:13.378 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 21:17:13.379 SERIAL » [ACK] (0x06) 21:17:13.380 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 21:18:49.698 SERIAL « 0x0110000400050a32022134000000000000c1 (18 bytes) 21:18:49.699 CNTRLR [Node 005] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 21:18:49.700 CNTRLR [Node 005] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 21:18:49.700 SERIAL » [ACK] (0x06) 21:18:49.701 DRIVER « [Node 005] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 21:19:07.896 SERIAL « 0x010c0004001a0631050422040bf6 (14 bytes) 21:19:07.897 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 21:19:07.898 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 87.6 => 103.5 [Endpoint 0] 21:19:07.898 SERIAL » [ACK] (0x06) 21:19:07.900 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 103.5 21:19:10.620 DRIVER destroying driver instance...