17:19:12.254 DRIVER ███████╗ ██╗ ██╗ █████╗ ██╗ ██╗ ███████╗ ██╗ ███████╗ ╚══███╔╝ ██║ ██║ ██╔══██╗ ██║ ██║ ██╔════╝ ██║ ██╔════╝ ███╔╝ ██║ █╗ ██║ ███████║ ██║ ██║ █████╗ █████╗ ██║ ███████╗ ███╔╝ ██║███╗██║ ██╔══██║ ╚██╗ ██╔╝ ██╔══╝ ╚════╝ ██ ██║ ╚════██║ ███████╗ ╚███╔███╔╝ ██║ ██║ ╚████╔╝ ███████╗ ╚█████╔╝ ███████║ ╚══════╝ ╚══╝╚══╝ ╚═╝ ╚═╝ ╚═══╝ ╚══════╝ ╚════╝ ╚══════╝ 17:19:12.263 DRIVER version 5.3.4 17:19:12.264 DRIVER 17:19:12.264 DRIVER starting driver... 17:19:12.291 DRIVER opening serial port /dev/ttyACM1 17:19:12.359 DRIVER serial port opened 17:19:12.365 SERIAL » [NAK] (0x15) 17:19:12.384 SERIAL « 0x0110000400070a7105000000ff070000006a (18 bytes) 17:19:12.391 SERIAL » [ACK] (0x06) 17:19:12.608 DRIVER Cannot handle message because the driver is not ready to handle it yet. 17:19:13.877 DRIVER loading configuration... 17:19:14.367 DRIVER beginning interview... 17:19:14.369 DRIVER added request handler for AddNodeToNetwork (0x4a)... 1 registered 17:19:14.369 DRIVER added request handler for RemoveNodeFromNetwork (0x4b)... 1 registered 17:19:14.372 CNTRLR beginning interview... 17:19:14.372 CNTRLR querying version info... 17:19:14.406 SERIAL » 0x01030015e9 (5 bytes) 17:19:14.408 DRIVER » [REQ] [GetControllerVersion] 17:19:14.412 SERIAL « [ACK] (0x06) 17:19:14.414 SERIAL « 0x011001155a2d5761766520342e3534000193 (18 bytes) 17:19:14.416 SERIAL » [ACK] (0x06) 17:19:14.417 DRIVER « [RES] [GetControllerVersion] payload: 0x5a2d5761766520342e35340001 17:19:14.426 CNTRLR received version info: controller type: Static Controller library version: Z-Wave 4.54 17:19:14.426 CNTRLR querying controller IDs... 17:19:14.433 SERIAL » 0x01030020dc (5 bytes) 17:19:14.434 DRIVER » [REQ] [GetControllerId] 17:19:14.437 SERIAL « [ACK] (0x06) 17:19:14.439 SERIAL « 0x01080120f314aee70179 (10 bytes) 17:19:14.441 SERIAL » [ACK] (0x06) 17:19:14.442 DRIVER « [RES] [GetControllerId] payload: 0xf314aee701 17:19:14.447 CNTRLR received controller IDs: home ID: 0xf314aee7 own node ID: 1 17:19:14.448 CNTRLR querying controller capabilities... 17:19:14.455 SERIAL » 0x01030005f9 (5 bytes) 17:19:14.455 DRIVER » [REQ] [GetControllerCapabilities] 17:19:14.458 SERIAL « [ACK] (0x06) 17:19:14.460 SERIAL « 0x0104010508f7 (6 bytes) 17:19:14.461 SERIAL » [ACK] (0x06) 17:19:14.462 DRIVER « [RES] [GetControllerCapabilities] payload: 0x08 17:19:14.467 CNTRLR received controller capabilities: controller role: primary is in other network: false is SIS present: false was real primary: true is a SUC: false 17:19:14.467 CNTRLR querying API capabilities... 17:19:14.474 SERIAL » 0x01030007fb (5 bytes) 17:19:14.475 DRIVER » [REQ] [GetSerialApiCapabilities] 17:19:14.477 SERIAL « [ACK] (0x06) 17:19:14.479 SERIAL « 0x012b0107010100860001005afe81ff884f1f0000fb9f7da067000080008086000 (45 bytes) 000e87300000e0000600000fa 17:19:14.481 SERIAL » [ACK] (0x06) 17:19:14.482 DRIVER « [RES] [GetSerialApiCapabilities] payload: 0x010100860001005afe81ff884f1f0000fb9f7da067000080008086000000e8730 0000e0000600000 17:19:14.487 CNTRLR received API capabilities: serial API version: 1.1 manufacturer ID: 0x86 product type: 0x01 product ID: 0x5a supported functions: · GetSerialApiInitData (0x02) · FUNC_ID_SERIAL_API_APPL_NODE_INFORMATION (0x03) · ApplicationCommand (0x04) · GetControllerCapabilities (0x05) · SetSerialApiTimeouts (0x06) · GetSerialApiCapabilities (0x07) · FUNC_ID_SERIAL_API_SOFT_RESET (0x08) · UNKNOWN_FUNC_UNKNOWN_0x09 (0x09) · UNKNOWN_FUNC_RF_RECEIVE_MODE (0x10) · UNKNOWN_FUNC_SET_SLEEP_MODE (0x11) · FUNC_ID_ZW_SEND_NODE_INFORMATION (0x12) · SendData (0x13) · SendDataMulticast (0x14) · GetControllerVersion (0x15) · SendDataAbort (0x16) · FUNC_ID_ZW_R_F_POWER_LEVEL_SET (0x17) · UNKNOWN_FUNC_SEND_DATA_META (0x18) · FUNC_ID_ZW_GET_RANDOM (0x1c) · GetControllerId (0x20) · UNKNOWN_FUNC_MEMORY_GET_BYTE (0x21) · UNKNOWN_FUNC_MEMORY_PUT_BYTE (0x22) · UNKNOWN_FUNC_MEMORY_GET_BUFFER (0x23) · UNKNOWN_FUNC_MEMORY_PUT_BUFFER (0x24) · UNKNOWN_FUNC_FlashAutoProgSet (0x27) · UNKNOWN_FUNC_NVMGetId (0x29) · UNKNOWN_FUNC_NVMExtReadLongBuffer (0x2a) · UNKNOWN_FUNC_NVMExtWriteLongBuffer (0x2b) · UNKNOWN_FUNC_NVMExtReadLongByte (0x2c) · UNKNOWN_FUNC_NVMExtWriteLongByte (0x2d) · GetNodeProtocolInfo (0x41) · HardReset (0x42) · FUNC_ID_ZW_REPLICATION_COMMAND_COMPLETE (0x44) · FUNC_ID_ZW_REPLICATION_SEND_DATA (0x45) · AssignReturnRoute (0x46) · DeleteReturnRoute (0x47) · RequestNodeNeighborUpdate (0x48) · ApplicationUpdateRequest (0x49) · AddNodeToNetwork (0x4a) · RemoveNodeFromNetwork (0x4b) · FUNC_ID_ZW_CREATE_NEW_PRIMARY (0x4c) · FUNC_ID_ZW_CONTROLLER_CHANGE (0x4d) · FUNC_ID_ZW_SET_LEARN_MODE (0x50) · FUNC_ID_ZW_ASSIGN_SUC_RETURN_ROUTE (0x51) · FUNC_ID_ZW_REQUEST_NETWORK_UPDATE (0x53) · FUNC_ID_ZW_SET_SUC_NODE_ID (0x54) · FUNC_ID_ZW_DELETE_SUC_RETURN_ROUTE (0x55) · GetSUCNodeId (0x56) · UNKNOWN_FUNC_SEND_SUC_ID (0x57) · FUNC_ID_ZW_EXPLORE_REQUEST_INCLUSION (0x5e) · RequestNodeInfo (0x60) · RemoveFailedNode (0x61) · IsFailedNode (0x62) · FUNC_ID_ZW_REPLACE_FAILED_NODE (0x63) · UNKNOWN_FUNC_UNKNOWN_0x66 (0x66) · UNKNOWN_FUNC_UNKNOWN_0x67 (0x67) · GetRoutingInfo (0x80) · UNKNOWN_FUNC_LOCK_ROUTE_RESPONSE (0x90) · UNKNOWN_FUNC_GET_PRIORITY_ROUTE (0x92) · UNKNOWN_FUNC_SET_PRIORITY_ROUTE (0x93) · UNKNOWN_FUNC_UNKNOWN_0x98 (0x98) · UNKNOWN_FUNC_UNKNOWN_0xB4 (0xb4) · UNKNOWN_FUNC_WATCH_DOG_ENABLE (0xb6) · UNKNOWN_FUNC_WATCH_DOG_DISABLE (0xb7) · UNKNOWN_FUNC_WATCH_DOG_KICK (0xb8) · UNKNOWN_FUNC_UNKNOWN_0xB9 (0xb9) · UNKNOWN_FUNC_RF_POWERLEVEL_GET (0xba) · UNKNOWN_FUNC_GET_LIBRARY_TYPE (0xbd) · UNKNOWN_FUNC_SEND_TEST_FRAME (0xbe) · UNKNOWN_FUNC_GET_PROTOCOL_STATUS (0xbf) · UNKNOWN_FUNC_UNKNOWN_0xD2 (0xd2) · UNKNOWN_FUNC_UNKNOWN_0xD3 (0xd3) · UNKNOWN_FUNC_UNKNOWN_0xD4 (0xd4) · undefined (0xee) · UNKNOWN_FUNC_UNKNOWN_0xEF (0xef) 17:19:14.488 CNTRLR finding SUC... 17:19:14.494 SERIAL » 0x01030056aa (5 bytes) 17:19:14.495 DRIVER » [REQ] [GetSUCNodeId] 17:19:14.497 SERIAL « [ACK] (0x06) 17:19:14.518 SERIAL « 0x0104015600ac (6 bytes) 17:19:14.519 SERIAL » [ACK] (0x06) 17:19:14.520 DRIVER « [RES] [GetSUCNodeId] payload: 0x00 17:19:14.525 CNTRLR no SUC present 17:19:15.041 CNTRLR querying node information... 17:19:15.054 SERIAL » 0x01030002fe (5 bytes) 17:19:15.055 DRIVER » [REQ] [GetSerialApiInitData] 17:19:15.057 SERIAL « [ACK] (0x06) 17:19:15.155 SERIAL « 0x0125010205001de7ffffff0700000000000000000000000000000000000000000 (39 bytes) 00000000500db 17:19:15.156 SERIAL » [ACK] (0x06) 17:19:15.157 DRIVER « [RES] [GetSerialApiInitData] payload: 0x05001de7ffffff070000000000000000000000000000000000000000000000000 500 17:19:15.162 CNTRLR received node information: controller role: primary controller is a SUC: false controller is a slave: false controller supports timers: false nodes in the network: 1, 2, 3, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35 17:19:15.242 DRIVER Cache file for homeId 0xf314aee7 found, attempting to restore the network from cache... 17:19:15.253 CNTRLR [Node 001] trying to load device config 17:19:15.263 CNTRLR [Node 001] device config loaded 17:19:15.264 CNTRLR [Node 002] trying to load device config 17:19:15.286 CNTRLR [Node 002] device config loaded 17:19:15.287 CNTRLR [Node 003] trying to load device config 17:19:15.301 CNTRLR [Node 003] device config loaded 17:19:15.304 CNTRLR [Node 006] trying to load device config 17:19:15.312 CNTRLR [Node 006] device config loaded 17:19:15.313 CNTRLR [Node 007] trying to load device config 17:19:15.339 CNTRLR [Node 007] device config loaded 17:19:15.340 CNTRLR [Node 008] trying to load device config 17:19:15.355 CNTRLR [Node 008] device config loaded 17:19:15.356 CNTRLR [Node 009] trying to load device config 17:19:15.373 CNTRLR [Node 009] device config loaded 17:19:15.373 CNTRLR [Node 010] trying to load device config 17:19:15.384 CNTRLR [Node 010] device config loaded 17:19:15.385 CNTRLR [Node 011] trying to load device config 17:19:15.388 CNTRLR [Node 011] device config loaded 17:19:15.389 CNTRLR [Node 012] trying to load device config 17:19:15.402 CNTRLR [Node 012] device config loaded 17:19:15.403 CNTRLR [Node 013] trying to load device config 17:19:15.412 CNTRLR [Node 013] device config loaded 17:19:15.413 CNTRLR [Node 014] trying to load device config 17:19:15.423 CNTRLR [Node 014] device config loaded 17:19:15.424 CNTRLR [Node 015] trying to load device config 17:19:15.440 CNTRLR [Node 015] device config loaded 17:19:15.441 CNTRLR [Node 016] trying to load device config 17:19:15.457 CNTRLR [Node 016] device config loaded 17:19:15.457 CNTRLR [Node 017] trying to load device config 17:19:15.470 CNTRLR [Node 017] device config loaded 17:19:15.473 CNTRLR [Node 018] trying to load device config 17:19:15.476 CNTRLR [Node 018] device config loaded 17:19:15.477 CNTRLR [Node 019] trying to load device config 17:19:15.488 CNTRLR [Node 019] device config loaded 17:19:15.489 CNTRLR [Node 020] trying to load device config 17:19:15.499 CNTRLR [Node 020] device config loaded 17:19:15.500 CNTRLR [Node 021] trying to load device config 17:19:15.512 CNTRLR [Node 021] device config loaded 17:19:15.514 CNTRLR [Node 022] trying to load device config 17:19:15.517 CNTRLR [Node 022] device config loaded 17:19:15.518 CNTRLR [Node 023] trying to load device config 17:19:15.531 CNTRLR [Node 023] device config loaded 17:19:15.532 CNTRLR [Node 024] trying to load device config 17:19:15.553 CNTRLR [Node 024] device config loaded 17:19:15.554 CNTRLR [Node 025] trying to load device config 17:19:15.567 CNTRLR [Node 025] device config loaded 17:19:15.568 CNTRLR [Node 026] trying to load device config 17:19:15.578 CNTRLR [Node 026] device config loaded 17:19:15.579 CNTRLR [Node 027] trying to load device config 17:19:15.590 CNTRLR [Node 027] device config loaded 17:19:15.592 CNTRLR [Node 028] trying to load device config 17:19:15.598 CNTRLR [Node 028] device config loaded 17:19:15.600 CNTRLR [Node 029] trying to load device config 17:19:15.604 CNTRLR [Node 029] device config loaded 17:19:15.605 CNTRLR [Node 030] trying to load device config 17:19:15.617 CNTRLR [Node 030] device config loaded 17:19:15.618 CNTRLR [Node 031] trying to load device config 17:19:15.630 CNTRLR [Node 031] device config loaded 17:19:15.630 CNTRLR [Node 032] trying to load device config 17:19:15.641 CNTRLR [Node 032] device config loaded 17:19:15.643 CNTRLR [Node 033] trying to load device config 17:19:15.651 CNTRLR [Node 033] device config loaded 17:19:15.653 CNTRLR [Node 034] trying to load device config 17:19:15.670 CNTRLR [Node 034] device config loaded 17:19:15.672 CNTRLR [Node 035] trying to load device config 17:19:15.687 CNTRLR [Node 035] device config loaded 17:19:15.687 DRIVER Restoring the network from cache was successful! 17:19:15.691 CNTRLR [Node 001] [Manufacturer Specific] manufacturerId: metadata updated 17:19:15.692 CNTRLR [Node 001] [Manufacturer Specific] productType: metadata updated 17:19:15.692 CNTRLR [Node 001] [Manufacturer Specific] productId: metadata updated 17:19:15.693 CNTRLR [Node 001] [~] [Manufacturer Specific] manufacturerId: 134 => 134 17:19:15.694 CNTRLR [Node 001] [~] [Manufacturer Specific] productType: 1 => 1 17:19:15.695 CNTRLR [Node 001] [~] [Manufacturer Specific] productId: 90 => 90 17:19:15.695 CNTRLR setting serial API timeouts: ack = 1000 ms, byte = 150 ms 17:19:15.701 SERIAL » 0x01050006640f97 (7 bytes) 17:19:15.702 DRIVER » [REQ] [SetSerialApiTimeouts] payload: 0x640f 17:19:15.704 SERIAL « [ACK] (0x06) 17:19:15.706 SERIAL « 0x01050106640f96 (7 bytes) 17:19:15.706 SERIAL » [ACK] (0x06) 17:19:15.708 DRIVER « [RES] [SetSerialApiTimeouts] payload: 0x640f 17:19:15.711 CNTRLR serial API timeouts overwritten. The old values were: ack = 1000 ms, byte = 15 0 ms 17:19:15.712 CNTRLR Interview completed 17:19:15.714 DRIVER driver ready 17:19:15.719 CNTRLR [Node 001] Beginning interview - last completed stage: RestartFromCache 17:19:15.721 CNTRLR [Node 001] not pinging the controller 17:19:15.784 CNTRLR [Node 001] Interview stage completed: CommandClasses 17:19:15.784 CNTRLR [Node 001] trying to load device config 17:19:15.788 CNTRLR [Node 001] device config loaded 17:19:15.789 CNTRLR [Node 001] Interview stage completed: OverwriteConfig 17:19:15.790 CNTRLR » [Node 001] requesting node neighbors... 17:19:15.828 SERIAL » 0x010700800100000079 (9 bytes) 17:19:15.829 DRIVER » [Node 001] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:19:15.833 SERIAL « [ACK] (0x06) 17:19:15.836 SERIAL « 0x01200180e4fffd6f0700000000000000000000000000000000000000000000000 (34 bytes) 0d0 17:19:15.837 SERIAL » [ACK] (0x06) 17:19:15.840 DRIVER « [RES] [GetRoutingInfo] node ids: 3, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 30, 31, 33, 34, 35 17:19:15.848 CNTRLR [Node 001] The node is alive. 17:19:15.849 CNTRLR [Node 001] The node is ready to be used 17:19:15.850 CNTRLR « [Node 001] node neighbors received: 3, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 1 6, 17, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 30, 31, 33, 34, 35 17:19:15.850 CNTRLR [Node 001] Interview stage completed: Neighbors 17:19:15.851 CNTRLR [Node 001] Interview completed 17:19:15.853 CNTRLR [Node 002] Beginning interview - last completed stage: RestartFromCache 17:19:15.854 CNTRLR » [Node 002] pinging the node... 17:19:15.869 SERIAL » 0x010800130201002501c3 (10 bytes) 17:19:15.870 DRIVER » [Node 002] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 1 └─[NoOperationCC] 17:19:15.871 CNTRLR [Node 003] Beginning interview - last completed stage: RestartFromCache 17:19:15.872 CNTRLR » [Node 003] pinging the node... 17:19:15.876 CNTRLR [Node 006] Beginning interview - last completed stage: RestartFromCache 17:19:15.877 CNTRLR » [Node 006] pinging the node... 17:19:15.882 CNTRLR [Node 007] Beginning interview - last completed stage: RestartFromCache 17:19:15.883 CNTRLR » [Node 007] pinging the node... 17:19:15.887 CNTRLR [Node 008] Beginning interview - last completed stage: RestartFromCache 17:19:15.889 CNTRLR » [Node 008] pinging the node... 17:19:15.892 CNTRLR [Node 009] Beginning interview - last completed stage: RestartFromCache 17:19:15.893 CNTRLR » [Node 009] pinging the node... 17:19:15.898 CNTRLR [Node 010] Beginning interview - last completed stage: RestartFromCache 17:19:15.899 CNTRLR » [Node 010] pinging the node... 17:19:15.902 CNTRLR [Node 011] Beginning interview - last completed stage: RestartFromCache 17:19:15.915 CNTRLR » [Node 011] pinging the node... 17:19:15.918 CNTRLR [Node 012] Beginning interview - last completed stage: RestartFromCache 17:19:15.920 CNTRLR » [Node 012] pinging the node... 17:19:15.923 CNTRLR [Node 013] Beginning interview - last completed stage: RestartFromCache 17:19:15.924 CNTRLR » [Node 013] pinging the node... 17:19:15.927 CNTRLR [Node 014] Beginning interview - last completed stage: RestartFromCache 17:19:15.928 CNTRLR » [Node 014] pinging the node... 17:19:15.930 CNTRLR [Node 015] Beginning interview - last completed stage: RestartFromCache 17:19:15.931 CNTRLR » [Node 015] pinging the node... 17:19:15.933 CNTRLR [Node 016] Beginning interview - last completed stage: RestartFromCache 17:19:15.934 CNTRLR » [Node 016] pinging the node... 17:19:15.937 CNTRLR [Node 017] Beginning interview - last completed stage: RestartFromCache 17:19:15.938 CNTRLR » [Node 017] pinging the node... 17:19:15.940 CNTRLR [Node 018] Beginning interview - last completed stage: RestartFromCache 17:19:15.941 CNTRLR » [Node 018] pinging the node... 17:19:15.943 CNTRLR [Node 019] Beginning interview - last completed stage: RestartFromCache 17:19:15.944 CNTRLR » [Node 019] pinging the node... 17:19:15.946 CNTRLR [Node 020] Beginning interview - last completed stage: RestartFromCache 17:19:15.947 CNTRLR » [Node 020] pinging the node... 17:19:15.950 CNTRLR [Node 021] Beginning interview - last completed stage: RestartFromCache 17:19:15.950 CNTRLR » [Node 021] pinging the node... 17:19:15.953 CNTRLR [Node 022] Beginning interview - last completed stage: RestartFromCache 17:19:15.954 CNTRLR » [Node 022] pinging the node... 17:19:15.956 CNTRLR [Node 023] Beginning interview - last completed stage: RestartFromCache 17:19:15.957 CNTRLR » [Node 023] pinging the node... 17:19:15.959 CNTRLR [Node 024] Beginning interview - last completed stage: RestartFromCache 17:19:15.960 CNTRLR » [Node 024] pinging the node... 17:19:15.962 CNTRLR [Node 025] Beginning interview - last completed stage: RestartFromCache 17:19:15.963 CNTRLR » [Node 025] pinging the node... 17:19:15.966 CNTRLR [Node 026] Beginning interview - last completed stage: RestartFromCache 17:19:15.966 CNTRLR » [Node 026] pinging the node... 17:19:15.969 CNTRLR [Node 027] Beginning interview - last completed stage: RestartFromCache 17:19:15.970 CNTRLR » [Node 027] pinging the node... 17:19:15.972 CNTRLR [Node 028] Beginning interview - last completed stage: RestartFromCache 17:19:15.973 CNTRLR » [Node 028] pinging the node... 17:19:15.975 CNTRLR [Node 029] Beginning interview - last completed stage: RestartFromCache 17:19:15.976 CNTRLR » [Node 029] pinging the node... 17:19:15.978 CNTRLR [Node 030] Beginning interview - last completed stage: RestartFromCache 17:19:15.979 CNTRLR » [Node 030] pinging the node... 17:19:15.982 CNTRLR [Node 031] Beginning interview - last completed stage: RestartFromCache 17:19:15.982 CNTRLR » [Node 031] pinging the node... 17:19:15.985 CNTRLR [Node 032] Beginning interview - last completed stage: RestartFromCache 17:19:15.986 CNTRLR » [Node 032] pinging the node... 17:19:15.988 CNTRLR [Node 033] Beginning interview - last completed stage: RestartFromCache 17:19:15.989 CNTRLR » [Node 033] pinging the node... 17:19:15.991 CNTRLR [Node 034] Beginning interview - last completed stage: RestartFromCache 17:19:15.992 CNTRLR » [Node 034] pinging the node... 17:19:15.994 CNTRLR [Node 035] Beginning interview - last completed stage: RestartFromCache 17:19:15.995 CNTRLR » [Node 035] pinging the node... 17:19:16.049 SERIAL « [ACK] (0x06) 17:19:16.051 SERIAL « 0x0104011301e8 (6 bytes) 17:19:16.052 SERIAL » [ACK] (0x06) 17:19:16.057 DRIVER « [RES] [SendData] was sent: true 17:19:20.168 SERIAL « 0x01070013010101a04a (9 bytes) 17:19:20.169 SERIAL » [ACK] (0x06) 17:19:20.170 DRIVER « [REQ] [SendData] callback id: 1 transmit status: NoAck 17:19:20.180 SERIAL » 0x010800130301002502c1 (10 bytes) 17:19:20.181 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 2 └─[NoOperationCC] 17:19:20.182 CNTRLR [Node 002] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 17:19:20.182 CNTRLR [Node 002] The node is asleep. 17:19:20.186 CNTRLR [Node 002] The node is ready to be used 17:19:20.187 CNTRLR [Node 002] ping failed: Failed to send the command after 1 attempts (Status No Ack) 17:19:20.192 CNTRLR [Node 002] ManufacturerSpecificCC: doing a partial interview... 17:19:20.193 CNTRLR [Node 002] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:19:20.258 SERIAL « [ACK] (0x06) 17:19:20.260 SERIAL « 0x0104011301e8 (6 bytes) 17:19:20.261 SERIAL » [ACK] (0x06) 17:19:20.264 DRIVER « [RES] [SendData] was sent: true 17:19:20.269 SERIAL « 0x0107001302000002eb (9 bytes) 17:19:20.270 SERIAL » [ACK] (0x06) 17:19:20.271 DRIVER « [REQ] [SendData] callback id: 2 transmit status: OK 17:19:20.283 SERIAL » 0x010800130601002503c5 (10 bytes) 17:19:20.284 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 3 └─[NoOperationCC] 17:19:20.285 CNTRLR « [Node 003] ping successful 17:19:20.286 CNTRLR [Node 003] ManufacturerSpecificCC: doing a partial interview... 17:19:20.287 CNTRLR [Node 003] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:19:20.289 CNTRLR [Node 003] VersionCC: doing a partial interview... 17:19:20.290 CNTRLR [Node 003] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:19:20.290 CNTRLR [Node 003] trying to load device config 17:19:20.295 SERIAL « [ACK] (0x06) 17:19:20.297 SERIAL « 0x0104011301e8 (6 bytes) 17:19:20.297 SERIAL » [ACK] (0x06) 17:19:20.300 DRIVER « [RES] [SendData] was sent: true 17:19:20.313 CNTRLR [Node 003] device config loaded 17:19:20.316 CNTRLR [Node 003] AssociationCC: doing a partial interview... 17:19:20.317 CNTRLR [Node 003] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:19:20.318 CNTRLR [Node 003] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:19:20.319 CNTRLR [Node 003] BinarySwitchCC: doing a partial interview... 17:19:20.319 CNTRLR » [Node 003] querying Binary Switch state... 17:19:20.337 CNTRLR [Node 002] VersionCC: doing a partial interview... 17:19:20.338 CNTRLR [Node 002] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:19:20.338 CNTRLR [Node 002] trying to load device config 17:19:20.666 CNTRLR [Node 002] device config loaded 17:19:20.668 CNTRLR [Node 002] ZWavePlusCC: doing a partial interview... 17:19:20.668 CNTRLR [Node 002] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 17:19:20.670 CNTRLR [Node 002] BatteryCC: doing a partial interview... 17:19:20.670 CNTRLR » [Node 002] querying battery status... 17:19:21.527 SERIAL « 0x010700130300007c94 (9 bytes) 17:19:21.527 SERIAL » [ACK] (0x06) 17:19:21.529 DRIVER « [REQ] [SendData] callback id: 3 transmit status: OK 17:19:21.536 SERIAL » 0x010800130701002504c3 (10 bytes) 17:19:21.537 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 4 └─[NoOperationCC] 17:19:21.538 CNTRLR « [Node 006] ping successful 17:19:21.572 SERIAL « [ACK] (0x06) 17:19:21.581 SERIAL « 0x0104011301e8 (6 bytes) 17:19:21.582 SERIAL » [ACK] (0x06) 17:19:21.584 DRIVER « [RES] [SendData] was sent: true 17:19:21.592 CNTRLR [Node 006] ManufacturerSpecificCC: doing a partial interview... 17:19:21.593 CNTRLR [Node 006] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:19:21.593 CNTRLR [Node 006] VersionCC: doing a partial interview... 17:19:21.594 CNTRLR [Node 006] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:19:21.594 CNTRLR [Node 006] trying to load device config 17:19:21.600 SERIAL « 0x0107001304000005ea (9 bytes) 17:19:21.601 SERIAL » [ACK] (0x06) 17:19:21.604 DRIVER « [REQ] [SendData] callback id: 4 transmit status: OK 17:19:21.611 SERIAL » 0x01090013030225022505e3 (11 bytes) 17:19:21.612 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 5 └─[BinarySwitchCCGet] 17:19:21.612 CNTRLR « [Node 007] ping successful 17:19:21.614 CNTRLR [Node 007] ManufacturerSpecificCC: doing a partial interview... 17:19:21.615 CNTRLR [Node 007] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:19:21.615 CNTRLR [Node 007] VersionCC: doing a partial interview... 17:19:21.616 CNTRLR [Node 007] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:19:21.616 CNTRLR [Node 007] trying to load device config 17:19:21.623 CNTRLR [Node 006] device config loaded 17:19:21.624 CNTRLR [Node 006] ZWavePlusCC: doing a partial interview... 17:19:21.624 CNTRLR [Node 006] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 17:19:21.626 CNTRLR » [Node 006] querying device endpoint information... 17:19:21.644 SERIAL « [ACK] (0x06) 17:19:21.645 SERIAL « 0x0104011301e8 (6 bytes) 17:19:21.646 SERIAL » [ACK] (0x06) 17:19:21.648 DRIVER « [RES] [SendData] was sent: true 17:19:21.663 CNTRLR [Node 007] device config loaded 17:19:21.664 CNTRLR [Node 007] ZWavePlusCC: doing a partial interview... 17:19:21.665 CNTRLR [Node 007] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 17:19:21.665 CNTRLR [Node 007] BatteryCC: doing a partial interview... 17:19:21.666 CNTRLR » [Node 007] querying battery status... 17:19:21.668 SERIAL « 0x0107001305000002ec (9 bytes) 17:19:21.669 SERIAL » [ACK] (0x06) 17:19:21.670 DRIVER « [REQ] [SendData] callback id: 5 transmit status: OK 17:19:21.678 SERIAL « 0x010900040003032503ff2b (11 bytes) 17:19:21.681 CNTRLR [Node 003] [~] [Binary Switch] currentValue: true => true [Endpoint 0] 17:19:21.682 SERIAL » [ACK] (0x06) 17:19:21.686 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: true 17:19:21.693 SERIAL » 0x0109001307028002250641 (11 bytes) 17:19:21.693 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 6 └─[BatteryCCGet] 17:19:21.694 CNTRLR [Node 003] The node is alive. 17:19:21.695 CNTRLR [Node 003] The node is ready to be used 17:19:21.697 CNTRLR « [Node 003] received Binary Switch state: current value: true 17:19:21.697 CNTRLR [Node 003] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 17:19:21.699 CNTRLR [Node 003] MultilevelSensorCC: doing a partial interview... 17:19:21.699 CNTRLR » [Node 003] querying current sensor reading... 17:19:21.718 SERIAL « [ACK] (0x06) 17:19:21.719 SERIAL « 0x0104011301e8 (6 bytes) 17:19:21.720 SERIAL » [ACK] (0x06) 17:19:21.723 DRIVER « [RES] [SendData] was sent: true 17:19:21.777 SERIAL « 0x0107001306000006eb (9 bytes) 17:19:21.778 SERIAL » [ACK] (0x06) 17:19:21.934 DRIVER « [REQ] [SendData] callback id: 6 transmit status: OK 17:19:23.128 SERIAL « 0x0109000400070380036411 (11 bytes) 17:19:23.129 CNTRLR [Node 007] [~] [Battery] level: 100 => 100 [Endpoint 0] 17:19:23.130 CNTRLR [Node 007] [~] [Battery] isLow: false => false [Endpoint 0] 17:19:23.131 SERIAL » [ACK] (0x06) 17:19:23.133 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 17:19:23.168 SERIAL » 0x010900130602984025071b (11 bytes) 17:19:23.169 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 7 └─[SecurityCCNonceGet] 17:19:23.170 CNTRLR « [Node 007] received response for battery information: level: 100 17:19:23.171 CNTRLR [Node 007] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:19:23.205 SERIAL « [ACK] (0x06) 17:19:23.212 SERIAL « 0x0104011301e8 (6 bytes) 17:19:23.213 SERIAL » [ACK] (0x06) 17:19:23.215 DRIVER « [RES] [SendData] was sent: true 17:19:23.219 CNTRLR [Node 007] WakeUpCC: doing a partial interview... 17:19:23.220 CNTRLR » [Node 007] retrieving wakeup interval from the device... 17:19:24.553 SERIAL « 0x010700130700007e92 (9 bytes) 17:19:24.554 SERIAL » [ACK] (0x06) 17:19:24.555 DRIVER « [REQ] [SendData] callback id: 7 transmit status: OK 17:19:24.559 SERIAL « 0x0110000400060a98807225c9437f0fe38637 (18 bytes) 17:19:24.561 SERIAL » [ACK] (0x06) 17:19:24.562 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x7225c9437f0fe386 17:19:24.564 CNTRLR [Node 006] The node is alive. 17:19:24.565 CNTRLR [Node 006] The node is ready to be used 17:19:24.572 SERIAL » 0x011d001306169881b9bbab7f17be21e126716872d0a8033baee74669250801 (31 bytes) 17:19:24.573 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 8 └─[SecurityCCCommandEncapsulation] │ nonce id: 114 └─[MultiChannelCCEndPointGet] 17:19:24.577 SERIAL « [ACK] (0x06) 17:19:24.586 SERIAL « 0x0104011301e8 (6 bytes) 17:19:24.586 SERIAL » [ACK] (0x06) 17:19:24.588 DRIVER « [RES] [SendData] was sent: true 17:19:25.300 SERIAL « 0x0107001308000003e0 (9 bytes) 17:19:25.301 SERIAL » [ACK] (0x06) 17:19:25.302 DRIVER « [REQ] [SendData] callback id: 8 transmit status: OK 17:19:25.307 SERIAL « 0x0108000400060298402f (10 bytes) 17:19:25.308 SERIAL » [ACK] (0x06) 17:19:25.310 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:19:25.327 SERIAL » 0x01110013060a9880e5059b1d834be12405098e (19 bytes) 17:19:25.328 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 9 └─[SecurityCCNonceReport] nonce: 0xe5059b1d834be124 17:19:25.332 SERIAL « [ACK] (0x06) 17:19:25.337 SERIAL « 0x0104011301e8 (6 bytes) 17:19:25.338 SERIAL » [ACK] (0x06) 17:19:25.339 DRIVER « [RES] [SendData] was sent: true 17:19:25.359 SERIAL « 0x0107001309000002e0 (9 bytes) 17:19:25.360 SERIAL » [ACK] (0x06) 17:19:25.361 DRIVER « [REQ] [SendData] callback id: 9 transmit status: OK 17:19:25.389 SERIAL « 0x011f00040006199881145e448793c1f3ea62f8ef3ced8be5f76ceb988830c58df (33 bytes) 2 17:19:25.392 SERIAL » [ACK] (0x06) 17:19:25.396 CNTRLR [Node 006] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 17:19:25.397 CNTRLR [Node 006] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 17:19:25.397 CNTRLR [Node 006] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 17:19:25.398 CNTRLR [Node 006] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 17:19:25.400 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 17:19:25.406 SERIAL » 0x0109001307028405250a4e (11 bytes) 17:19:25.407 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 10 └─[WakeUpCCIntervalGet] 17:19:25.408 CNTRLR « [Node 006] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 17:19:25.408 CNTRLR » [Node 006] querying all endpoints... 17:19:25.416 SERIAL « [ACK] (0x06) 17:19:25.417 SERIAL « 0x0104011301e8 (6 bytes) 17:19:25.419 SERIAL » [ACK] (0x06) 17:19:25.420 DRIVER « [RES] [SendData] was sent: true 17:19:25.469 SERIAL « 0x010700130a000005e4 (9 bytes) 17:19:25.470 SERIAL » [ACK] (0x06) 17:19:25.471 DRIVER « [REQ] [SendData] callback id: 10 transmit status: OK 17:19:25.546 SERIAL « 0x010c00040007068406000e10016b (14 bytes) 17:19:25.548 CNTRLR [Node 007] [~] [Wake Up] wakeUpInterval: 3600 => 3600 [Endpoint 0] 17:19:25.549 CNTRLR [Node 007] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 17:19:25.549 SERIAL » [ACK] (0x06) 17:19:25.551 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 3600 seconds controller node id: 1 17:19:25.558 SERIAL » 0x0109001303023104250bff (11 bytes) 17:19:25.559 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 11 └─[MultilevelSensorCCGet] 17:19:25.561 CNTRLR « [Node 007] received wakeup configuration: wakeup interval: 3600 seconds controller node: 1 17:19:25.561 CNTRLR [Node 007] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:19:25.594 SERIAL « [ACK] (0x06) 17:19:25.603 SERIAL « 0x0104011301e8 (6 bytes) 17:19:25.604 SERIAL » [ACK] (0x06) 17:19:25.605 DRIVER « [RES] [SendData] was sent: true 17:19:25.609 CNTRLR [Node 007] BasicCC: doing a partial interview... 17:19:25.609 CNTRLR » [Node 007] querying Basic CC state... 17:19:25.635 SERIAL « 0x010700130b000007e7 (9 bytes) 17:19:25.636 SERIAL » [ACK] (0x06) 17:19:25.637 DRIVER « [REQ] [SendData] callback id: 11 transmit status: OK 17:19:25.646 SERIAL « 0x010c0004000306310504220935dc (14 bytes) 17:19:25.649 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:19:25.650 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 209 => 235.7 [Endpoint 0] 17:19:25.651 SERIAL » [ACK] (0x06) 17:19:25.652 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 235.7 17:19:25.660 SERIAL » 0x0109001307022002250ceb (11 bytes) 17:19:25.661 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 12 └─[BasicCCGet] 17:19:25.662 CNTRLR « [Node 003] received current sensor reading: sensor type: Power value: 235.7 W 17:19:25.662 CNTRLR [Node 003] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 17:19:25.664 CNTRLR [Node 003] MeterCC: doing a partial interview... 17:19:25.664 CNTRLR » [Node 003] querying default meter value... 17:19:25.682 SERIAL « [ACK] (0x06) 17:19:25.684 SERIAL « 0x0104011301e8 (6 bytes) 17:19:25.685 SERIAL » [ACK] (0x06) 17:19:25.685 DRIVER « [RES] [SendData] was sent: true 17:19:25.722 SERIAL « 0x010700130c000006e1 (9 bytes) 17:19:25.723 SERIAL » [ACK] (0x06) 17:19:25.724 DRIVER « [REQ] [SendData] callback id: 12 transmit status: OK 17:19:25.804 SERIAL « 0x01090004000703200300d5 (11 bytes) 17:19:25.806 SERIAL » [ACK] (0x06) 17:19:25.807 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BasicCCReport] current value: 0 17:19:25.814 SERIAL » 0x0109001306029840250d11 (11 bytes) 17:19:25.815 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 13 └─[SecurityCCNonceGet] 17:19:25.816 CNTRLR « [Node 007] received Basic CC state: current value: 0 17:19:25.816 CNTRLR [Node 007] [~] [Basic] interviewComplete: true => true [Endpoint 0] [internal] 17:19:25.845 SERIAL « [ACK] (0x06) 17:19:25.848 SERIAL « 0x0104011301e8 (6 bytes) 17:19:25.849 SERIAL » [ACK] (0x06) 17:19:25.850 DRIVER « [RES] [SendData] was sent: true 17:19:25.856 CNTRLR [Node 007] BinarySensorCC: doing a partial interview... 17:19:25.857 CNTRLR » [Node 007] querying current value... 17:19:25.866 SERIAL « 0x010c00040003063105042206ed0b (14 bytes) 17:19:25.867 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:19:25.868 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 235.7 => 177.3 [Endpoint 0] 17:19:25.869 SERIAL » [ACK] (0x06) 17:19:25.871 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 177.3 17:19:25.874 SERIAL « 0x010c00040003063105042206ed0b (14 bytes) 17:19:25.876 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:19:25.876 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 177.3 => 177.3 [Endpoint 0] 17:19:25.877 SERIAL » [ACK] (0x06) 17:19:25.878 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 177.3 17:19:27.246 SERIAL « 0x010700130d00008761 (9 bytes) 17:19:27.247 SERIAL » [ACK] (0x06) 17:19:27.250 DRIVER « [REQ] [SendData] callback id: 13 transmit status: OK 17:19:27.257 SERIAL « 0x0110000400060a98805fa4d510d1c8b8c0a0 (18 bytes) 17:19:27.258 SERIAL » [ACK] (0x06) 17:19:27.260 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x5fa4d510d1c8b8c0 17:19:27.266 SERIAL » 0x011f001306189881369d62510190da5f6035ebc3325f38bceda92197e92b250ef (33 bytes) 7 17:19:27.267 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 14 └─[SecurityCCCommandEncapsulation] │ nonce id: 95 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 17:19:27.271 SERIAL « 0x010c00040003063105042203fa19 (14 bytes) 17:19:27.273 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:19:27.274 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 177.3 => 101.8 [Endpoint 0] 17:19:27.274 SERIAL » [ACK] (0x06) 17:19:27.275 SERIAL « [CAN] (0x18) 17:19:27.277 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 17:19:27.280 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 101.8 17:19:27.378 SERIAL » 0x011f001306189881369d62510190da5f6035ebc3325f38bceda92197e92b250ef (33 bytes) 7 17:19:27.379 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 14 └─[SecurityCCCommandEncapsulation] │ nonce id: 95 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 17:19:27.383 SERIAL « [ACK] (0x06) 17:19:27.390 SERIAL « 0x0104011301e8 (6 bytes) 17:19:27.390 SERIAL » [ACK] (0x06) 17:19:27.392 DRIVER « [RES] [SendData] was sent: true 17:19:27.414 SERIAL « 0x010700130e000003e6 (9 bytes) 17:19:27.415 SERIAL » [ACK] (0x06) 17:19:27.416 DRIVER « [REQ] [SendData] callback id: 14 transmit status: OK 17:19:27.437 SERIAL « 0x0108000400060298402f (10 bytes) 17:19:27.438 SERIAL » [ACK] (0x06) 17:19:27.440 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:19:27.449 SERIAL » 0x01110013060a988018bdf5546b473618050fe5 (19 bytes) 17:19:27.450 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 15 └─[SecurityCCNonceReport] nonce: 0x18bdf5546b473618 17:19:27.453 SERIAL « [ACK] (0x06) 17:19:27.459 SERIAL « 0x0104011301e8 (6 bytes) 17:19:27.460 SERIAL » [ACK] (0x06) 17:19:27.463 DRIVER « [RES] [SendData] was sent: true 17:19:27.482 SERIAL « 0x010700130f000003e7 (9 bytes) 17:19:27.482 SERIAL » [ACK] (0x06) 17:19:27.484 DRIVER « [REQ] [SendData] callback id: 15 transmit status: OK 17:19:27.511 SERIAL « 0x0121000400061b9881352b0cef4ce84e61cff96ea97fa2e66118e2c3fec1cb167 (35 bytes) be744 17:19:27.513 SERIAL » [ACK] (0x06) 17:19:27.516 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 17:19:27.522 SERIAL » 0x01090013070230022510e7 (11 bytes) 17:19:27.524 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[BinarySensorCCGet] type: Any 17:19:27.525 CNTRLR « [Node 006] received endpoints: 1, 2 17:19:27.525 CNTRLR » [Node 006] querying capabilities for endpoint #1... 17:19:27.530 SERIAL « [ACK] (0x06) 17:19:27.533 SERIAL « 0x0104011301e8 (6 bytes) 17:19:27.533 SERIAL » [ACK] (0x06) 17:19:27.537 DRIVER « [RES] [SendData] was sent: true 17:19:27.585 SERIAL « 0x0107001310000006fd (9 bytes) 17:19:27.586 SERIAL » [ACK] (0x06) 17:19:27.587 DRIVER « [REQ] [SendData] callback id: 16 transmit status: OK 17:19:27.666 SERIAL « 0x01090004000703300300c5 (11 bytes) 17:19:27.668 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:19:27.669 CNTRLR [Node 007] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:19:27.671 SERIAL » [ACK] (0x06) 17:19:27.672 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:19:27.679 SERIAL » 0x01090013030232012511e3 (11 bytes) 17:19:27.680 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 17 └─[MeterCCGet] 17:19:27.681 CNTRLR « [Node 007] received current value: false 17:19:27.682 CNTRLR [Node 007] [~] [Binary Sensor] interviewComplete: true [Endpoint 0] [internal] => true 17:19:27.710 SERIAL « [ACK] (0x06) 17:19:27.715 SERIAL « 0x0104011301e8 (6 bytes) 17:19:27.716 SERIAL » [ACK] (0x06) 17:19:27.717 DRIVER « [RES] [SendData] was sent: true 17:19:27.720 CNTRLR [Node 007] MultilevelSensorCC: doing a partial interview... 17:19:27.720 CNTRLR » [Node 007] querying current sensor reading... 17:19:27.756 SERIAL « 0x0107001311000007fd (9 bytes) 17:19:27.756 SERIAL » [ACK] (0x06) 17:19:27.757 DRIVER « [REQ] [SendData] callback id: 17 transmit status: OK 17:19:27.767 SERIAL « 0x010e0004000308320201440000241bb4 (16 bytes) 17:19:27.770 CNTRLR [Node 003] [~] [Meter] value[65536]: 92.29 => 92.43 [Endpoint 0] 17:19:27.771 CNTRLR [Node 003] [~] [Meter] deltaTime[65536]: 0 => 0 [Endpoint 0] 17:19:27.772 SERIAL » [ACK] (0x06) 17:19:27.774 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Unspecified value: 92.43 time delta: 0 seconds 17:19:27.780 SERIAL » 0x01090013070231042512e2 (11 bytes) 17:19:27.780 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 18 └─[MultilevelSensorCCGet] 17:19:27.782 CNTRLR [Node 003] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 17:19:27.783 CNTRLR [Node 003] ConfigurationCC: Loading configuration parameters from device confi g 17:19:27.793 CNTRLR [Node 003] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:19:27.795 CNTRLR [Node 003] [Configuration] 1: metadata updated 17:19:27.797 CNTRLR [Node 003] [Configuration] 16: metadata updated 17:19:27.798 CNTRLR [Node 003] [Configuration] 34: metadata updated 17:19:27.800 CNTRLR [Node 003] [Configuration] 35: metadata updated 17:19:27.801 CNTRLR [Node 003] [Configuration] 39: metadata updated 17:19:27.802 CNTRLR [Node 003] [Configuration] 40: metadata updated 17:19:27.803 CNTRLR [Node 003] [Configuration] 42: metadata updated 17:19:27.804 CNTRLR [Node 003] [Configuration] 43: metadata updated 17:19:27.806 CNTRLR [Node 003] [Configuration] 45: metadata updated 17:19:27.807 CNTRLR [Node 003] [Configuration] 47: metadata updated 17:19:27.808 CNTRLR [Node 003] [Configuration] 49: metadata updated 17:19:27.809 CNTRLR [Node 003] [Configuration] 50: metadata updated 17:19:27.811 CNTRLR [Node 003] [Configuration] 51: metadata updated 17:19:27.812 CNTRLR [Node 003] [Configuration] 52: metadata updated 17:19:27.813 CNTRLR [Node 003] [Configuration] 60: metadata updated 17:19:27.814 CNTRLR [Node 003] [Configuration] 61: metadata updated 17:19:27.818 CNTRLR [Node 003] [Configuration] 62: metadata updated 17:19:27.819 CNTRLR [Node 003] [Configuration] 63: metadata updated 17:19:27.820 CNTRLR [Node 003] [Configuration] 70: metadata updated 17:19:27.822 CNTRLR [Node 003] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:19:27.823 CNTRLR » [Node 003] querying parameter #1 value... 17:19:27.850 SERIAL « [ACK] (0x06) 17:19:27.855 SERIAL « 0x0104011301e8 (6 bytes) 17:19:27.856 SERIAL » [ACK] (0x06) 17:19:27.857 DRIVER « [RES] [SendData] was sent: true 17:19:27.862 SERIAL « 0x0107001312000006ff (9 bytes) 17:19:27.863 SERIAL » [ACK] (0x06) 17:19:27.863 DRIVER « [REQ] [SendData] callback id: 18 transmit status: OK 17:19:27.868 SERIAL « 0x010c00040003063105042207eb0c (14 bytes) 17:19:27.870 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:19:27.871 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 101.8 => 202.7 [Endpoint 0] 17:19:27.872 SERIAL » [ACK] (0x06) 17:19:27.873 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 202.7 17:19:28.514 SERIAL « 0x010c00040007063105012200be5f (14 bytes) 17:19:28.515 CNTRLR [Node 007] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 17:19:28.516 CNTRLR [Node 007] [~] [Multilevel Sensor] Air temperature: 19 => 19 [Endpoint 0] 17:19:28.517 SERIAL » [ACK] (0x06) 17:19:28.519 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 19 17:19:28.538 SERIAL » 0x010900130602984025130f (11 bytes) 17:19:28.538 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 19 └─[SecurityCCNonceGet] 17:19:28.540 CNTRLR « [Node 007] received current sensor reading: sensor type: Air temperature value: 19 °C 17:19:28.540 CNTRLR [Node 007] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 17:19:28.570 SERIAL « [ACK] (0x06) 17:19:28.583 SERIAL « 0x0104011301e8 (6 bytes) 17:19:28.584 SERIAL » [ACK] (0x06) 17:19:28.585 DRIVER « [RES] [SendData] was sent: true 17:19:28.589 CNTRLR [Node 007] ConfigurationCC: Loading configuration parameters from device confi g 17:19:28.596 CNTRLR [Node 007] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:19:28.597 CNTRLR [Node 007] [Configuration] 2: metadata updated 17:19:28.598 CNTRLR [Node 007] [Configuration] 3: metadata updated 17:19:28.600 CNTRLR [Node 007] [Configuration] 4: metadata updated 17:19:28.601 CNTRLR [Node 007] [Configuration] 5: metadata updated 17:19:28.603 CNTRLR [Node 007] [Configuration] 8: metadata updated 17:19:28.605 CNTRLR [Node 007] [Configuration] 9: metadata updated 17:19:28.606 CNTRLR [Node 007] [Configuration] 39: metadata updated 17:19:28.607 CNTRLR [Node 007] [Configuration] 40: metadata updated 17:19:28.608 CNTRLR [Node 007] [Configuration] 42: metadata updated 17:19:28.609 CNTRLR [Node 007] [Configuration] 43: metadata updated 17:19:28.610 CNTRLR [Node 007] [Configuration] 44: metadata updated 17:19:28.612 CNTRLR [Node 007] [Configuration] 45: metadata updated 17:19:28.613 CNTRLR [Node 007] [Configuration] 46: metadata updated 17:19:28.614 CNTRLR [Node 007] [Configuration] 81: metadata updated 17:19:28.615 CNTRLR [Node 007] [Configuration] 100: metadata updated 17:19:28.616 CNTRLR [Node 007] [Configuration] 110: metadata updated 17:19:28.618 CNTRLR [Node 007] [Configuration] 111: metadata updated 17:19:28.619 CNTRLR [Node 007] [Configuration] 112: metadata updated 17:19:28.620 CNTRLR [Node 007] [Configuration] 113: metadata updated 17:19:28.621 CNTRLR [Node 007] [Configuration] 201: metadata updated 17:19:28.622 CNTRLR [Node 007] [Configuration] 202: metadata updated 17:19:28.623 CNTRLR [Node 007] [Configuration] 203: metadata updated 17:19:28.625 CNTRLR [Node 007] [Configuration] 204: metadata updated 17:19:28.626 CNTRLR [Node 007] [Configuration] 252: metadata updated 17:19:28.627 CNTRLR [Node 007] [Configuration] 255: metadata updated 17:19:28.628 CNTRLR [Node 007] [Configuration] 101[1]: metadata updated 17:19:28.630 CNTRLR [Node 007] [Configuration] 101[16]: metadata updated 17:19:28.631 CNTRLR [Node 007] [Configuration] 101[32]: metadata updated 17:19:28.632 CNTRLR [Node 007] [Configuration] 101[64]: metadata updated 17:19:28.633 CNTRLR [Node 007] [Configuration] 101[128]: metadata updated 17:19:28.634 CNTRLR [Node 007] [Configuration] 102[1]: metadata updated 17:19:28.636 CNTRLR [Node 007] [Configuration] 102[16]: metadata updated 17:19:28.640 CNTRLR [Node 007] [Configuration] 102[32]: metadata updated 17:19:28.641 CNTRLR [Node 007] [Configuration] 102[64]: metadata updated 17:19:28.643 CNTRLR [Node 007] [Configuration] 102[128]: metadata updated 17:19:28.644 CNTRLR [Node 007] [Configuration] 103[1]: metadata updated 17:19:28.646 CNTRLR [Node 007] [Configuration] 103[16]: metadata updated 17:19:28.647 CNTRLR [Node 007] [Configuration] 103[32]: metadata updated 17:19:28.648 CNTRLR [Node 007] [Configuration] 103[64]: metadata updated 17:19:28.650 CNTRLR [Node 007] [Configuration] 103[128]: metadata updated 17:19:28.652 CNTRLR [Node 007] [Configuration] 41[15]: metadata updated 17:19:28.653 CNTRLR [Node 007] [Configuration] 41[16776960]: metadata updated 17:19:28.654 CNTRLR [Node 007] [Configuration] 201[255]: metadata updated 17:19:28.655 CNTRLR [Node 007] [Configuration] 201[65280]: metadata updated 17:19:28.656 CNTRLR [Node 007] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:19:28.657 CNTRLR » [Node 007] querying parameter #2 value... 17:19:29.832 SERIAL « 0x010700131300007d85 (9 bytes) 17:19:29.833 SERIAL » [ACK] (0x06) 17:19:29.835 DRIVER « [REQ] [SendData] callback id: 19 transmit status: OK 17:19:29.840 SERIAL « 0x0110000400060a98806f096f932ff7961239 (18 bytes) 17:19:29.841 SERIAL » [ACK] (0x06) 17:19:29.842 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x6f096f932ff79612 17:19:29.848 SERIAL » 0x011e001306179881fcc506393b64704014c73f836ffb278010239d7d4025146d (32 bytes) 17:19:29.849 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 20 └─[SecurityCCCommandEncapsulation] │ nonce id: 111 └─[MultiChannelCCCapabilityGet] endpoint: 1 17:19:29.852 SERIAL « [ACK] (0x06) 17:19:29.860 SERIAL « 0x0104011301e8 (6 bytes) 17:19:29.861 SERIAL » [ACK] (0x06) 17:19:29.862 DRIVER « [RES] [SendData] was sent: true 17:19:29.886 SERIAL « 0x0107001314000003fc (9 bytes) 17:19:29.887 SERIAL » [ACK] (0x06) 17:19:29.887 DRIVER « [REQ] [SendData] callback id: 20 transmit status: OK 17:19:29.908 SERIAL « 0x0108000400060298402f (10 bytes) 17:19:29.909 SERIAL » [ACK] (0x06) 17:19:29.910 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:19:29.918 SERIAL » 0x01110013060a9880c94ea4d48e560fac051575 (19 bytes) 17:19:29.918 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 21 └─[SecurityCCNonceReport] nonce: 0xc94ea4d48e560fac 17:19:29.922 SERIAL « [ACK] (0x06) 17:19:29.927 SERIAL « 0x0104011301e8 (6 bytes) 17:19:29.928 SERIAL » [ACK] (0x06) 17:19:29.928 DRIVER « [RES] [SendData] was sent: true 17:19:29.948 SERIAL « 0x0107001315000002fc (9 bytes) 17:19:29.949 SERIAL » [ACK] (0x06) 17:19:29.950 DRIVER « [REQ] [SendData] callback id: 21 transmit status: OK 17:19:29.987 SERIAL « 0x0123000400061d98812ec43fb35e6588795897f9c669ea65d483acc966c130cc0 (37 bytes) d2769410b 17:19:29.989 SERIAL » [ACK] (0x06) 17:19:29.992 CNTRLR [Node 006] [~] [Multi Channel] commandClasses: 94,152, [Endpoint 1] [internal] 159,34 => 94,152,159,34 17:19:29.993 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 17:19:30.003 SERIAL » 0x010a001307037005022516a6 (12 bytes) 17:19:30.005 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 22 └─[ConfigurationCCGet] parameter #: 2 17:19:30.005 CNTRLR « [Node 006] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 17:19:30.006 CNTRLR » [Node 006] querying capabilities for endpoint #2... 17:19:30.015 SERIAL « [ACK] (0x06) 17:19:30.017 SERIAL « 0x0104011301e8 (6 bytes) 17:19:30.017 SERIAL » [ACK] (0x06) 17:19:30.019 DRIVER « [RES] [SendData] was sent: true 17:19:30.263 SERIAL « 0x0107001316000006fb (9 bytes) 17:19:30.264 SERIAL » [ACK] (0x06) 17:19:30.265 DRIVER « [REQ] [SendData] callback id: 22 transmit status: OK 17:19:30.271 SERIAL « 0x010b0004000705700602010087 (13 bytes) 17:19:30.280 CNTRLR [Node 007] [~] [Configuration] 2: 0 => 0 17:19:30.281 SERIAL » [ACK] (0x06) 17:19:30.283 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 0 17:19:30.289 SERIAL » 0x010a001303037005012517a0 (12 bytes) 17:19:30.290 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 23 └─[ConfigurationCCGet] parameter #: 1 17:19:30.291 CNTRLR « [Node 007] parameter #2 has value: 0 17:19:30.291 CNTRLR » [Node 007] querying parameter #3 value... 17:19:30.303 SERIAL « [ACK] (0x06) 17:19:30.305 SERIAL « 0x0104011301e8 (6 bytes) 17:19:30.306 SERIAL » [ACK] (0x06) 17:19:30.308 DRIVER « [RES] [SendData] was sent: true 17:19:30.316 SERIAL « 0x0107001317000002fe (9 bytes) 17:19:30.317 SERIAL » [ACK] (0x06) 17:19:30.318 DRIVER « [REQ] [SendData] callback id: 23 transmit status: OK 17:19:30.328 SERIAL « 0x010b0004000305700601010181 (13 bytes) 17:19:30.335 CNTRLR [Node 003] [~] [Configuration] 1: 1 => 1 17:19:30.336 SERIAL » [ACK] (0x06) 17:19:30.337 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 1 17:19:30.342 SERIAL » 0x010a001307037005032518a9 (12 bytes) 17:19:30.342 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 24 └─[ConfigurationCCGet] parameter #: 3 17:19:30.343 CNTRLR « [Node 003] parameter #1 has value: 1 17:19:30.343 CNTRLR » [Node 003] querying parameter #16 value... 17:19:30.347 SERIAL « [ACK] (0x06) 17:19:30.353 SERIAL « 0x0104011301e8 (6 bytes) 17:19:30.354 SERIAL » [ACK] (0x06) 17:19:30.355 DRIVER « [RES] [SendData] was sent: true 17:19:30.405 SERIAL « 0x0107001318000006f5 (9 bytes) 17:19:30.405 SERIAL » [ACK] (0x06) 17:19:30.407 DRIVER « [REQ] [SendData] callback id: 24 transmit status: OK 17:19:30.486 SERIAL « 0x010c000400070670060302000a8b (14 bytes) 17:19:30.492 CNTRLR [Node 007] [~] [Configuration] 3: 10 => 10 17:19:30.493 SERIAL » [ACK] (0x06) 17:19:30.494 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 2 value: 10 17:19:30.501 SERIAL » 0x0109001306029840251905 (11 bytes) 17:19:30.502 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 25 └─[SecurityCCNonceGet] 17:19:30.502 CNTRLR « [Node 007] parameter #3 has value: 10 17:19:30.503 CNTRLR » [Node 007] querying parameter #4 value... 17:19:30.509 SERIAL « [ACK] (0x06) 17:19:30.512 SERIAL « 0x0104011301e8 (6 bytes) 17:19:30.512 SERIAL » [ACK] (0x06) 17:19:30.513 DRIVER « [RES] [SendData] was sent: true 17:19:31.840 SERIAL « 0x010700131900008577 (9 bytes) 17:19:31.840 SERIAL » [ACK] (0x06) 17:19:31.841 DRIVER « [REQ] [SendData] callback id: 25 transmit status: OK 17:19:32.563 SERIAL « 0x0110000400060a9880a75691d84825b823b1 (18 bytes) 17:19:32.564 SERIAL » [ACK] (0x06) 17:19:32.565 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xa75691d84825b823 17:19:32.570 SERIAL » 0x011e001306179881e07ed99abc084e8fe5a8b57ca7032bbc3232cc4771251a20 (32 bytes) 17:19:32.571 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 26 └─[SecurityCCCommandEncapsulation] │ nonce id: 167 └─[MultiChannelCCCapabilityGet] endpoint: 2 17:19:32.574 SERIAL « [ACK] (0x06) 17:19:32.582 SERIAL « 0x0104011301e8 (6 bytes) 17:19:32.583 SERIAL » [ACK] (0x06) 17:19:32.584 DRIVER « [RES] [SendData] was sent: true 17:19:32.606 SERIAL « 0x010700131a000003f2 (9 bytes) 17:19:32.607 SERIAL » [ACK] (0x06) 17:19:32.608 DRIVER « [REQ] [SendData] callback id: 26 transmit status: OK 17:19:32.628 SERIAL « 0x0108000400060298402f (10 bytes) 17:19:32.629 SERIAL » [ACK] (0x06) 17:19:32.631 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:19:32.637 SERIAL » 0x01110013060a98805a193e1fbf57362b051b60 (19 bytes) 17:19:32.638 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 27 └─[SecurityCCNonceReport] nonce: 0x5a193e1fbf57362b 17:19:32.640 SERIAL « [ACK] (0x06) 17:19:32.646 SERIAL « 0x0104011301e8 (6 bytes) 17:19:32.647 SERIAL » [ACK] (0x06) 17:19:32.648 DRIVER « [RES] [SendData] was sent: true 17:19:32.668 SERIAL « 0x010700131b000002f2 (9 bytes) 17:19:32.669 SERIAL » [ACK] (0x06) 17:19:32.670 DRIVER « [REQ] [SendData] callback id: 27 transmit status: OK 17:19:32.699 SERIAL « 0x0123000400061d9881cd92fc9a8fa89b86409e0fa9d3ab5662a23a5ae3694c9b6 (37 bytes) 59b546fb7 17:19:32.700 SERIAL » [ACK] (0x06) 17:19:32.702 CNTRLR [Node 006] [~] [Multi Channel] commandClasses: 94,152, [Endpoint 2] [internal] 159,34 => 94,152,159,34 17:19:32.703 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 17:19:32.708 SERIAL » 0x010a00130703700504251caa (12 bytes) 17:19:32.709 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 28 └─[ConfigurationCCGet] parameter #: 4 17:19:32.710 CNTRLR « [Node 006] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Security · Security 2 · Application Status 17:19:32.710 CNTRLR [Node 006] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 17:19:32.746 SERIAL « [ACK] (0x06) 17:19:32.760 SERIAL « 0x0104011301e8 (6 bytes) 17:19:32.761 SERIAL » [ACK] (0x06) 17:19:32.764 DRIVER « [RES] [SendData] was sent: true 17:19:32.768 CNTRLR [Node 006] BatteryCC: doing a partial interview... 17:19:32.768 CNTRLR » [Node 006] querying battery status... 17:19:32.772 SERIAL « 0x010700131c000006f1 (9 bytes) 17:19:32.773 SERIAL » [ACK] (0x06) 17:19:32.773 DRIVER « [REQ] [SendData] callback id: 28 transmit status: OK 17:19:32.976 SERIAL « 0x010b0004000705700604010584 (13 bytes) 17:19:32.982 CNTRLR [Node 007] [~] [Configuration] 4: 5 => 5 17:19:32.983 SERIAL » [ACK] (0x06) 17:19:33.014 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 1 value: 5 17:19:33.019 SERIAL » 0x010a00130303700510251dbb (12 bytes) 17:19:33.020 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 29 └─[ConfigurationCCGet] parameter #: 16 17:19:33.021 CNTRLR « [Node 007] parameter #4 has value: 5 17:19:33.021 CNTRLR » [Node 007] querying parameter #5 value... 17:19:33.030 SERIAL « [ACK] (0x06) 17:19:33.032 SERIAL « 0x0104011301e8 (6 bytes) 17:19:33.032 SERIAL » [ACK] (0x06) 17:19:33.035 DRIVER « [RES] [SendData] was sent: true 17:19:33.046 SERIAL « 0x010700131d000002f4 (9 bytes) 17:19:33.046 SERIAL » [ACK] (0x06) 17:19:33.047 DRIVER « [REQ] [SendData] callback id: 29 transmit status: OK 17:19:33.056 SERIAL « 0x010b0004000305700610010190 (13 bytes) 17:19:33.063 CNTRLR [Node 003] [~] [Configuration] 16: 1 => 1 17:19:33.064 SERIAL » [ACK] (0x06) 17:19:33.066 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 1 17:19:33.072 SERIAL » 0x010a00130703700505251ea9 (12 bytes) 17:19:33.073 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 30 └─[ConfigurationCCGet] parameter #: 5 17:19:33.073 CNTRLR « [Node 003] parameter #16 has value: 1 17:19:33.074 CNTRLR » [Node 003] querying parameter #34 value... 17:19:33.080 SERIAL « [ACK] (0x06) 17:19:33.082 SERIAL « 0x0104011301e8 (6 bytes) 17:19:33.083 SERIAL » [ACK] (0x06) 17:19:33.084 DRIVER « [RES] [SendData] was sent: true 17:19:33.135 SERIAL « 0x010700131e000006f3 (9 bytes) 17:19:33.135 SERIAL » [ACK] (0x06) 17:19:33.136 DRIVER « [REQ] [SendData] callback id: 30 transmit status: OK 17:19:33.215 SERIAL « 0x010b0004000705700605010282 (13 bytes) 17:19:33.222 CNTRLR [Node 007] [~] [Configuration] 5: 2 => 2 17:19:33.223 SERIAL » [ACK] (0x06) 17:19:33.225 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 1 value: 2 17:19:33.233 SERIAL » 0x0109001306029840251f03 (11 bytes) 17:19:33.233 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 31 └─[SecurityCCNonceGet] 17:19:33.235 CNTRLR « [Node 007] parameter #5 has value: 2 17:19:33.235 CNTRLR » [Node 007] querying parameter #8 value... 17:19:33.240 SERIAL « [ACK] (0x06) 17:19:33.242 SERIAL « 0x0104011301e8 (6 bytes) 17:19:33.243 SERIAL » [ACK] (0x06) 17:19:33.244 DRIVER « [RES] [SendData] was sent: true 17:19:34.554 SERIAL « 0x010700131f00008470 (9 bytes) 17:19:34.555 SERIAL » [ACK] (0x06) 17:19:34.556 DRIVER « [REQ] [SendData] callback id: 31 transmit status: OK 17:19:34.576 SERIAL « 0x0110000400060a98803ab2c8de507fdeb222 (18 bytes) 17:19:34.577 SERIAL » [ACK] (0x06) 17:19:34.578 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x3ab2c8de507fdeb2 17:19:34.583 SERIAL » 0x011d0013061698817e682ca85f648beb237e2b3a570a1e27cedbd5e9252035 (31 bytes) 17:19:34.584 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 32 └─[SecurityCCCommandEncapsulation] │ nonce id: 58 └─[BatteryCCGet] 17:19:34.587 SERIAL « [ACK] (0x06) 17:19:34.594 SERIAL « 0x0104011301e8 (6 bytes) 17:19:34.594 SERIAL » [ACK] (0x06) 17:19:34.595 DRIVER « [RES] [SendData] was sent: true 17:19:34.618 SERIAL « 0x0107001320000003c8 (9 bytes) 17:19:34.619 SERIAL » [ACK] (0x06) 17:19:34.620 DRIVER « [REQ] [SendData] callback id: 32 transmit status: OK 17:19:34.736 SERIAL « 0x0108000400060298402f (10 bytes) 17:19:34.737 SERIAL » [ACK] (0x06) 17:19:34.738 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:19:34.746 SERIAL » 0x01110013060a9880e86b9654ee2a3170052109 (19 bytes) 17:19:34.747 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 33 └─[SecurityCCNonceReport] nonce: 0xe86b9654ee2a3170 17:19:34.750 SERIAL « [ACK] (0x06) 17:19:34.756 SERIAL « 0x0104011301e8 (6 bytes) 17:19:34.756 SERIAL » [ACK] (0x06) 17:19:34.757 DRIVER « [RES] [SendData] was sent: true 17:19:34.787 SERIAL « 0x0107001321000003c9 (9 bytes) 17:19:34.788 SERIAL » [ACK] (0x06) 17:19:34.789 DRIVER « [REQ] [SendData] callback id: 33 transmit status: OK 17:19:34.807 SERIAL « 0x011d00040006179881ea98ef761196ad7b43cbdc55e8220d7c1f825e33425c (31 bytes) 17:19:34.809 SERIAL » [ACK] (0x06) 17:19:34.811 CNTRLR [Node 006] [~] [Battery] level: 12 => 11 [Endpoint 0] 17:19:34.812 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 0] 17:19:34.812 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[BatteryCCReport] level: 11 is low: false 17:19:34.817 SERIAL » 0x010a00130703700508252298 (12 bytes) 17:19:34.818 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 34 └─[ConfigurationCCGet] parameter #: 8 17:19:34.819 CNTRLR « [Node 006] received response for battery information: level: 11 17:19:34.819 CNTRLR [Node 006] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:19:34.850 SERIAL « [ACK] (0x06) 17:19:34.856 SERIAL « 0x0104011301e8 (6 bytes) 17:19:34.862 SERIAL » [ACK] (0x06) 17:19:34.864 DRIVER « [RES] [SendData] was sent: true 17:19:34.881 CNTRLR [Node 006] ZWavePlusCC: doing a partial interview... [Endpoint 1] 17:19:34.881 CNTRLR [Node 006] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 17:19:34.883 CNTRLR [Node 006] ThermostatModeCC: doing a partial interview... [Endpoint 1] 17:19:34.883 CNTRLR » [Node 006] querying current thermostat mode... [Endpoint 1] 17:19:34.893 SERIAL « 0x0107001322000006cf (9 bytes) 17:19:34.894 SERIAL » [ACK] (0x06) 17:19:34.895 DRIVER « [REQ] [SendData] callback id: 34 transmit status: OK 17:19:34.967 SERIAL « 0x010b0004000705700608010f82 (13 bytes) 17:19:34.975 CNTRLR [Node 007] [~] [Configuration] 8: 15 => 15 17:19:34.977 SERIAL » [ACK] (0x06) 17:19:34.979 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 15 17:19:34.985 SERIAL » 0x010a001303037005222523b7 (12 bytes) 17:19:34.986 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 35 └─[ConfigurationCCGet] parameter #: 34 17:19:34.987 CNTRLR « [Node 007] parameter #8 has value: 15 17:19:34.988 CNTRLR » [Node 007] querying parameter #9 value... 17:19:34.999 SERIAL « [ACK] (0x06) 17:19:35.000 SERIAL « 0x0104011301e8 (6 bytes) 17:19:35.001 SERIAL » [ACK] (0x06) 17:19:35.005 DRIVER « [RES] [SendData] was sent: true 17:19:35.059 SERIAL « 0x0107001323000006ce (9 bytes) 17:19:35.060 SERIAL » [ACK] (0x06) 17:19:35.061 DRIVER « [REQ] [SendData] callback id: 35 transmit status: OK 17:19:35.067 SERIAL « 0x010b0004000305700622013f9c (13 bytes) 17:19:35.072 CNTRLR [Node 003] [~] [Configuration] 34: 63 => 63 17:19:35.073 SERIAL » [ACK] (0x06) 17:19:35.074 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 34 value size: 1 value: 63 17:19:35.078 SERIAL » 0x010a0013070370050925249f (12 bytes) 17:19:35.079 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 36 └─[ConfigurationCCGet] parameter #: 9 17:19:35.080 CNTRLR « [Node 003] parameter #34 has value: 63 17:19:35.080 CNTRLR » [Node 003] querying parameter #35 value... 17:19:35.089 SERIAL « [ACK] (0x06) 17:19:35.090 SERIAL « 0x0104011301e8 (6 bytes) 17:19:35.091 SERIAL » [ACK] (0x06) 17:19:35.092 DRIVER « [RES] [SendData] was sent: true 17:19:35.141 SERIAL « 0x0107001324000006c9 (9 bytes) 17:19:35.142 SERIAL » [ACK] (0x06) 17:19:35.142 DRIVER « [REQ] [SendData] callback id: 36 transmit status: OK 17:19:35.227 SERIAL « 0x010c00040007067006090200008b (14 bytes) 17:19:35.232 CNTRLR [Node 007] [~] [Configuration] 9: 0 => 0 17:19:35.233 SERIAL » [ACK] (0x06) 17:19:35.234 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 2 value: 0 17:19:35.240 SERIAL » 0x0109001306029840252539 (11 bytes) 17:19:35.241 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 37 └─[SecurityCCNonceGet] 17:19:35.244 CNTRLR « [Node 007] parameter #9 has value: 0 17:19:35.244 CNTRLR » [Node 007] querying parameter #39 value... 17:19:35.248 SERIAL « [ACK] (0x06) 17:19:35.252 SERIAL « 0x0104011301e8 (6 bytes) 17:19:35.253 SERIAL » [ACK] (0x06) 17:19:35.255 DRIVER « [RES] [SendData] was sent: true 17:19:35.319 SERIAL « 0x0107001325000007c9 (9 bytes) 17:19:35.320 SERIAL » [ACK] (0x06) 17:19:35.320 DRIVER « [REQ] [SendData] callback id: 37 transmit status: OK 17:19:35.341 SERIAL « 0x0110000400060a98801247db1debe98d3cdf (18 bytes) 17:19:35.342 SERIAL » [ACK] (0x06) 17:19:35.343 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x1247db1debe98d3c 17:19:35.348 SERIAL » 0x01210013061a98815ec7b8bf7db809daa6134d6f6e9e8e1273522a6fa644cd0a2 (35 bytes) 526f9 17:19:35.349 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 38 └─[SecurityCCCommandEncapsulation] │ nonce id: 18 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 17:19:35.352 SERIAL « [ACK] (0x06) 17:19:35.360 SERIAL « 0x0104011301e8 (6 bytes) 17:19:35.360 SERIAL » [ACK] (0x06) 17:19:35.362 DRIVER « [RES] [SendData] was sent: true 17:19:35.385 SERIAL « 0x0107001326000003ce (9 bytes) 17:19:35.386 SERIAL » [ACK] (0x06) 17:19:35.387 DRIVER « [REQ] [SendData] callback id: 38 transmit status: OK 17:19:35.633 SERIAL « 0x0108000400060298402f (10 bytes) 17:19:35.634 SERIAL » [ACK] (0x06) 17:19:35.636 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:19:35.645 SERIAL » 0x01110013060a9880fd403ea79e4e976a0527c2 (19 bytes) 17:19:35.646 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 39 └─[SecurityCCNonceReport] nonce: 0xfd403ea79e4e976a 17:19:35.650 SERIAL « [ACK] (0x06) 17:19:35.655 SERIAL « 0x0104011301e8 (6 bytes) 17:19:35.656 SERIAL » [ACK] (0x06) 17:19:35.657 DRIVER « [RES] [SendData] was sent: true 17:19:35.677 SERIAL « 0x0107001327000002ce (9 bytes) 17:19:35.678 SERIAL » [ACK] (0x06) 17:19:35.678 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 17:19:35.707 SERIAL « 0x0121000400061b98814a2e6e6e9488f9196580b728878bf7a2fd7bf99a155463b (35 bytes) a233b 17:19:35.708 SERIAL » [ACK] (0x06) 17:19:35.710 CNTRLR [Node 006] [~] [Thermostat Mode] mode: 0 => 0 [Endpoint 1] 17:19:35.716 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Off 17:19:35.721 SERIAL » 0x010a001307037005272528bd (12 bytes) 17:19:35.722 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 40 └─[ConfigurationCCGet] parameter #: 39 17:19:35.724 CNTRLR « [Node 006] received current thermostat mode: Off [Endpoint 1] 17:19:35.724 CNTRLR [Node 006] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 1] [internal] ue => true 17:19:35.758 SERIAL « [ACK] (0x06) 17:19:35.762 SERIAL « 0x0104011301e8 (6 bytes) 17:19:35.763 SERIAL » [ACK] (0x06) 17:19:35.764 DRIVER « [RES] [SendData] was sent: true 17:19:35.770 CNTRLR [Node 006] ThermostatSetpointCC: doing a partial interview... [Endpoint 1] 17:19:35.771 CNTRLR » [Node 006] querying current value of setpoint Heating... [Endpoint 1] 17:19:35.800 SERIAL « 0x0107001328000006c5 (9 bytes) 17:19:35.801 SERIAL » [ACK] (0x06) 17:19:35.803 DRIVER « [REQ] [SendData] callback id: 40 transmit status: OK 17:19:35.874 SERIAL « 0x010c000400030631050422096b82 (14 bytes) 17:19:35.876 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:19:35.877 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 202.7 => 241.1 [Endpoint 0] 17:19:35.878 SERIAL » [ACK] (0x06) 17:19:35.879 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 241.1 17:19:35.914 SERIAL « 0x010b00040007057006270114b6 (13 bytes) 17:19:35.919 CNTRLR [Node 007] [~] [Configuration] 39: 20 => 20 17:19:35.920 SERIAL » [ACK] (0x06) 17:19:35.921 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 39 value size: 1 value: 20 17:19:35.926 SERIAL » 0x010a001303037005232529bc (12 bytes) 17:19:35.927 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 41 └─[ConfigurationCCGet] parameter #: 35 17:19:35.928 CNTRLR « [Node 007] parameter #39 has value: 20 17:19:35.928 CNTRLR » [Node 007] querying parameter #40 value... 17:19:35.932 SERIAL « [ACK] (0x06) 17:19:35.936 SERIAL « 0x0104011301e8 (6 bytes) 17:19:35.940 SERIAL » [ACK] (0x06) 17:19:35.941 DRIVER « [RES] [SendData] was sent: true 17:19:36.006 SERIAL « 0x0107001329000007c5 (9 bytes) 17:19:36.007 SERIAL » [ACK] (0x06) 17:19:36.008 DRIVER « [REQ] [SendData] callback id: 41 transmit status: OK 17:19:36.021 SERIAL « 0x010b00040003057006230100a2 (13 bytes) 17:19:36.026 CNTRLR [Node 003] [~] [Configuration] 35: 0 => 0 17:19:36.027 SERIAL » [ACK] (0x06) 17:19:36.029 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 0 17:19:36.034 SERIAL » 0x010a00130703700528252ab0 (12 bytes) 17:19:36.035 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 42 └─[ConfigurationCCGet] parameter #: 40 17:19:36.036 CNTRLR « [Node 003] parameter #35 has value: 0 17:19:36.036 CNTRLR » [Node 003] querying parameter #39 value... 17:19:36.041 SERIAL « [ACK] (0x06) 17:19:36.043 SERIAL « 0x0104011301e8 (6 bytes) 17:19:36.044 SERIAL » [ACK] (0x06) 17:19:36.046 DRIVER « [RES] [SendData] was sent: true 17:19:36.097 SERIAL « 0x010700132a000006c7 (9 bytes) 17:19:36.097 SERIAL » [ACK] (0x06) 17:19:36.098 DRIVER « [REQ] [SendData] callback id: 42 transmit status: OK 17:19:36.175 SERIAL « 0x010b00040007057006280100ad (13 bytes) 17:19:36.181 CNTRLR [Node 007] [~] [Configuration] 40: 0 => 0 17:19:36.182 SERIAL » [ACK] (0x06) 17:19:36.183 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 0 17:19:36.189 SERIAL » 0x0109001306029840252b37 (11 bytes) 17:19:36.190 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 43 └─[SecurityCCNonceGet] 17:19:36.191 CNTRLR « [Node 007] parameter #40 has value: 0 17:19:36.191 CNTRLR » [Node 007] querying parameter #42 value... 17:19:36.196 SERIAL « [ACK] (0x06) 17:19:36.199 SERIAL « 0x0104011301e8 (6 bytes) 17:19:36.200 SERIAL » [ACK] (0x06) 17:19:36.200 DRIVER « [RES] [SendData] was sent: true 17:19:36.270 SERIAL « 0x010700132b000008c8 (9 bytes) 17:19:36.271 SERIAL » [ACK] (0x06) 17:19:36.272 DRIVER « [REQ] [SendData] callback id: 43 transmit status: OK 17:19:36.292 SERIAL « 0x0110000400060a988073da12dad3594699cb (18 bytes) 17:19:36.293 SERIAL » [ACK] (0x06) 17:19:36.293 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x73da12dad3594699 17:19:36.298 SERIAL » 0x01220013061b98817196e4d1d03c96e6bf9748f8f92e7e3873723c12256e81e57 (36 bytes) b252cff 17:19:36.299 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 44 └─[SecurityCCCommandEncapsulation] │ nonce id: 115 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 17:19:36.303 SERIAL « [ACK] (0x06) 17:19:36.543 SERIAL « 0x0104011301e8 (6 bytes) 17:19:36.544 SERIAL » [ACK] (0x06) 17:19:36.546 DRIVER « [RES] [SendData] was sent: true 17:19:36.549 SERIAL « 0x010700132c000003c4 (9 bytes) 17:19:36.549 SERIAL » [ACK] (0x06) 17:19:36.550 DRIVER « [REQ] [SendData] callback id: 44 transmit status: OK 17:19:36.554 SERIAL « 0x0108000400060298402f (10 bytes) 17:19:36.554 SERIAL » [ACK] (0x06) 17:19:36.556 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:19:36.563 SERIAL » 0x01110013060a9880fcda49221818c1bc052df1 (19 bytes) 17:19:36.563 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 45 └─[SecurityCCNonceReport] nonce: 0xfcda49221818c1bc 17:19:36.566 SERIAL « [ACK] (0x06) 17:19:36.572 SERIAL « 0x0104011301e8 (6 bytes) 17:19:36.573 SERIAL » [ACK] (0x06) 17:19:36.573 DRIVER « [RES] [SendData] was sent: true 17:19:36.594 SERIAL « 0x010700132d000003c5 (9 bytes) 17:19:36.595 SERIAL » [ACK] (0x06) 17:19:36.597 DRIVER « [REQ] [SendData] callback id: 45 transmit status: OK 17:19:36.625 SERIAL « 0x0124000400061e9881981c8b30c3d5f8e9f020de2a0a6862daa73e99fc419250f (38 bytes) 91bb4472d5b 17:19:36.627 SERIAL » [ACK] (0x06) 17:19:36.632 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpoint[1]: 25 => 25 [Endpoint 1] 17:19:36.633 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 17:19:36.634 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 25 °C 17:19:36.639 SERIAL » 0x010a0013070370052a252eb6 (12 bytes) 17:19:36.645 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 46 └─[ConfigurationCCGet] parameter #: 42 17:19:36.646 CNTRLR « [Node 006] received current value of setpoint Heating: 25 °C [Endpoint 1] 17:19:36.647 CNTRLR [Node 006] [~] [Thermostat Setpoint] interviewComplete [Endpoint 1] [internal] : true => true 17:19:36.678 SERIAL « [ACK] (0x06) 17:19:36.681 SERIAL « 0x0104011301e8 (6 bytes) 17:19:36.682 SERIAL » [ACK] (0x06) 17:19:36.684 DRIVER « [RES] [SendData] was sent: true 17:19:36.688 CNTRLR [Node 006] NotificationCC: doing a partial interview... [Endpoint 1] 17:19:36.689 CNTRLR » [Node 006] querying notification status for Power Management... [Endpoint 1] 17:19:36.707 SERIAL « 0x010700132e000006c3 (9 bytes) 17:19:36.708 SERIAL » [ACK] (0x06) 17:19:36.708 DRIVER « [REQ] [SendData] callback id: 46 transmit status: OK 17:19:36.785 SERIAL « 0x010b000400070570062a010aa5 (13 bytes) 17:19:36.792 CNTRLR [Node 007] [~] [Configuration] 42: 10 => 10 17:19:36.793 SERIAL » [ACK] (0x06) 17:19:36.794 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 10 17:19:36.800 SERIAL » 0x010a00130303700527252fbe (12 bytes) 17:19:36.801 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 47 └─[ConfigurationCCGet] parameter #: 39 17:19:36.802 CNTRLR « [Node 007] parameter #42 has value: 10 17:19:36.802 CNTRLR » [Node 007] querying parameter #43 value... 17:19:36.815 SERIAL « [ACK] (0x06) 17:19:36.816 SERIAL « 0x0104011301e8 (6 bytes) 17:19:36.817 SERIAL » [ACK] (0x06) 17:19:36.817 DRIVER « [RES] [SendData] was sent: true 17:19:36.867 SERIAL « 0x010c000400030631050422079473 (14 bytes) 17:19:36.869 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:19:36.870 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 241.1 => 194 [Endpoint 0] 17:19:36.871 SERIAL » [ACK] (0x06) 17:19:36.872 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 194 17:19:36.884 SERIAL « 0x010700132f000008cc (9 bytes) 17:19:36.885 SERIAL » [ACK] (0x06) 17:19:36.886 DRIVER « [REQ] [SendData] callback id: 47 transmit status: OK 17:19:36.963 SERIAL « 0x010c000400030631050422079473 (14 bytes) 17:19:36.968 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:19:36.970 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 194 => 194 [Endpoint 0] 17:19:36.971 SERIAL » [ACK] (0x06) 17:19:36.975 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 194 17:19:36.982 SERIAL « 0x010c0004000306700627020258fb (14 bytes) 17:19:36.992 CNTRLR [Node 003] [~] [Configuration] 39: 600 => 600 17:19:36.993 SERIAL » [ACK] (0x06) 17:19:36.994 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 39 value size: 2 value: 600 17:19:36.998 SERIAL » 0x010a0013070370052b2530a9 (12 bytes) 17:19:36.999 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 48 └─[ConfigurationCCGet] parameter #: 43 17:19:37.000 CNTRLR « [Node 003] parameter #39 has value: 600 17:19:37.000 CNTRLR » [Node 003] querying parameter #40 value... 17:19:37.005 SERIAL « [ACK] (0x06) 17:19:37.009 SERIAL « 0x0104011301e8 (6 bytes) 17:19:37.011 SERIAL » [ACK] (0x06) 17:19:37.012 DRIVER « [RES] [SendData] was sent: true 17:19:37.061 SERIAL « 0x0107001330000006dd (9 bytes) 17:19:37.062 SERIAL » [ACK] (0x06) 17:19:37.062 DRIVER « [REQ] [SendData] callback id: 48 transmit status: OK 17:19:37.146 SERIAL « 0x010c000400070670062b020064cd (14 bytes) 17:19:37.151 CNTRLR [Node 007] [~] [Configuration] 43: 100 => 100 17:19:37.152 SERIAL » [ACK] (0x06) 17:19:37.153 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 2 value: 100 17:19:37.159 SERIAL » 0x010900130602984025312d (11 bytes) 17:19:37.160 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 49 └─[SecurityCCNonceGet] 17:19:37.161 CNTRLR « [Node 007] parameter #43 has value: 100 17:19:37.161 CNTRLR » [Node 007] querying parameter #44 value... 17:19:37.165 SERIAL « [ACK] (0x06) 17:19:37.171 SERIAL « 0x0104011301e8 (6 bytes) 17:19:37.172 SERIAL » [ACK] (0x06) 17:19:37.174 DRIVER « [RES] [SendData] was sent: true 17:19:37.239 SERIAL « 0x0107001331000007dd (9 bytes) 17:19:37.240 SERIAL » [ACK] (0x06) 17:19:37.240 DRIVER « [REQ] [SendData] callback id: 49 transmit status: OK 17:19:37.488 SERIAL « 0x0110000400060a9880fe96578cefe042babb (18 bytes) 17:19:37.489 SERIAL » [ACK] (0x06) 17:19:37.490 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xfe96578cefe042ba 17:19:37.495 SERIAL » 0x01240013061d9881c29efc6408471eeedab84735404bcd948104fe3ee6e365c6f (38 bytes) b2ff825322b 17:19:37.496 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 50 └─[SecurityCCCommandEncapsulation] │ nonce id: 254 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: Power Management 17:19:37.500 SERIAL « [ACK] (0x06) 17:19:37.507 SERIAL « 0x0104011301e8 (6 bytes) 17:19:37.508 SERIAL » [ACK] (0x06) 17:19:37.508 DRIVER « [RES] [SendData] was sent: true 17:19:37.533 SERIAL « 0x0107001332000003da (9 bytes) 17:19:37.534 SERIAL » [ACK] (0x06) 17:19:37.535 DRIVER « [REQ] [SendData] callback id: 50 transmit status: OK 17:19:37.554 SERIAL « 0x0108000400060298402f (10 bytes) 17:19:37.555 SERIAL » [ACK] (0x06) 17:19:37.556 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:19:37.563 SERIAL » 0x01110013060a988079d6a573bdec8659053328 (19 bytes) 17:19:37.563 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 51 └─[SecurityCCNonceReport] nonce: 0x79d6a573bdec8659 17:19:37.566 SERIAL « [ACK] (0x06) 17:19:37.572 SERIAL « 0x0104011301e8 (6 bytes) 17:19:37.573 SERIAL » [ACK] (0x06) 17:19:37.573 DRIVER « [RES] [SendData] was sent: true 17:19:37.594 SERIAL « 0x0107001333000003db (9 bytes) 17:19:37.595 SERIAL » [ACK] (0x06) 17:19:37.596 DRIVER « [REQ] [SendData] callback id: 51 transmit status: OK 17:19:37.628 SERIAL « 0x012700040006219881d8f563aad53d124e842e62b89df47e789a8e30de3fda794 (41 bytes) a178cdc6db597e069 17:19:37.629 SERIAL » [ACK] (0x06) 17:19:37.632 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 17:19:37.638 SERIAL » 0x010a0013070370052c2534aa (12 bytes) 17:19:37.639 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 52 └─[ConfigurationCCGet] parameter #: 44 17:19:37.642 CNTRLR [Node 006] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 1] 54 17:19:37.643 CNTRLR » [Node 006] querying notification status for System... [Endpoint 1] 17:19:37.658 SERIAL « [ACK] (0x06) 17:19:37.660 SERIAL « 0x0104011301e8 (6 bytes) 17:19:37.661 SERIAL » [ACK] (0x06) 17:19:37.662 DRIVER « [RES] [SendData] was sent: true 17:19:37.703 SERIAL « 0x0107001334000006d9 (9 bytes) 17:19:37.703 SERIAL » [ACK] (0x06) 17:19:37.704 DRIVER « [REQ] [SendData] callback id: 52 transmit status: OK 17:19:37.785 SERIAL « 0x010b000400070570062c010aa3 (13 bytes) 17:19:37.791 CNTRLR [Node 007] [~] [Configuration] 44: 10 => 10 17:19:37.792 SERIAL » [ACK] (0x06) 17:19:37.793 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 44 value size: 1 value: 10 17:19:37.812 SERIAL » 0x010a001303037005282535ab (12 bytes) 17:19:37.812 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 53 └─[ConfigurationCCGet] parameter #: 40 17:19:37.813 CNTRLR « [Node 007] parameter #44 has value: 10 17:19:37.814 CNTRLR » [Node 007] querying parameter #45 value... 17:19:37.825 SERIAL « [ACK] (0x06) 17:19:37.827 SERIAL « 0x0104011301e8 (6 bytes) 17:19:37.828 SERIAL » [ACK] (0x06) 17:19:37.829 DRIVER « [RES] [SendData] was sent: true 17:19:37.844 SERIAL « 0x010c0004000306310504220330d3 (14 bytes) 17:19:37.845 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:19:37.848 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 194 => 81.6 [Endpoint 0] 17:19:37.849 SERIAL » [ACK] (0x06) 17:19:37.852 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 81.6 17:19:37.884 SERIAL « 0x0107001335000007d9 (9 bytes) 17:19:37.885 SERIAL » [ACK] (0x06) 17:19:37.886 DRIVER « [REQ] [SendData] callback id: 53 transmit status: OK 17:19:37.942 SERIAL « 0x010c0004000306310504220330d3 (14 bytes) 17:19:37.943 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:19:37.944 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 81.6 => 81.6 [Endpoint 0] 17:19:37.944 SERIAL » [ACK] (0x06) 17:19:37.945 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 81.6 17:19:37.960 SERIAL « 0x010b00040003057006280150f9 (13 bytes) 17:19:37.965 CNTRLR [Node 003] [~] [Configuration] 40: 80 => 80 17:19:37.966 SERIAL » [ACK] (0x06) 17:19:37.967 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 80 17:19:37.971 SERIAL » 0x010a0013070370052d2536a9 (12 bytes) 17:19:37.972 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 54 └─[ConfigurationCCGet] parameter #: 45 17:19:37.972 CNTRLR « [Node 003] parameter #40 has value: 80 17:19:37.972 CNTRLR » [Node 003] querying parameter #42 value... 17:19:37.977 SERIAL « [ACK] (0x06) 17:19:37.980 SERIAL « 0x0104011301e8 (6 bytes) 17:19:37.981 SERIAL » [ACK] (0x06) 17:19:37.982 DRIVER « [RES] [SendData] was sent: true 17:19:38.033 SERIAL « 0x0107001336000006db (9 bytes) 17:19:38.034 SERIAL » [ACK] (0x06) 17:19:38.035 DRIVER « [REQ] [SendData] callback id: 54 transmit status: OK 17:19:38.115 SERIAL « 0x010b000400070570062d0102aa (13 bytes) 17:19:38.121 CNTRLR [Node 007] [~] [Configuration] 45: 2 => 2 17:19:38.122 SERIAL » [ACK] (0x06) 17:19:38.123 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 45 value size: 1 value: 2 17:19:38.138 SERIAL » 0x010900130602984025372b (11 bytes) 17:19:38.138 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 55 └─[SecurityCCNonceGet] 17:19:38.140 CNTRLR « [Node 007] parameter #45 has value: 2 17:19:38.140 CNTRLR » [Node 007] querying parameter #46 value... 17:19:38.145 SERIAL « [ACK] (0x06) 17:19:38.148 SERIAL « 0x0104011301e8 (6 bytes) 17:19:38.148 SERIAL » [ACK] (0x06) 17:19:38.149 DRIVER « [RES] [SendData] was sent: true 17:19:38.209 SERIAL « 0x0107001337000006da (9 bytes) 17:19:38.210 SERIAL » [ACK] (0x06) 17:19:38.211 DRIVER « [REQ] [SendData] callback id: 55 transmit status: OK 17:19:38.232 SERIAL « 0x0110000400060a9880058751ceba3d3196c2 (18 bytes) 17:19:38.233 SERIAL » [ACK] (0x06) 17:19:38.236 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x058751ceba3d3196 17:19:38.241 SERIAL » 0x01240013061d988149db19a6de54539a70ce07211d48e738380b058b6cea899d6 (38 bytes) 7cadb2538f2 17:19:38.242 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 56 └─[SecurityCCCommandEncapsulation] │ nonce id: 5 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: System 17:19:38.248 SERIAL « [ACK] (0x06) 17:19:38.255 SERIAL « 0x0104011301e8 (6 bytes) 17:19:38.256 SERIAL » [ACK] (0x06) 17:19:38.258 DRIVER « [RES] [SendData] was sent: true 17:19:38.968 SERIAL « 0x0107001338000004d7 (9 bytes) 17:19:38.969 SERIAL » [ACK] (0x06) 17:19:38.970 DRIVER « [REQ] [SendData] callback id: 56 transmit status: OK 17:19:38.974 SERIAL « 0x0108000400060298402f (10 bytes) 17:19:38.975 SERIAL » [ACK] (0x06) 17:19:38.976 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:19:38.985 SERIAL » 0x01110013060a98807601439ef75413cf053900 (19 bytes) 17:19:38.985 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 57 └─[SecurityCCNonceReport] nonce: 0x7601439ef75413cf 17:19:38.987 SERIAL « 0x01090004001b03200100cb (11 bytes) 17:19:38.989 SERIAL » [ACK] (0x06) 17:19:38.990 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:19:38.992 CNTRLR [Node 027] treating BasicCC Set as a report 17:19:38.993 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:19:38.994 SERIAL « [CAN] (0x18) 17:19:38.996 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 17:19:39.105 SERIAL » 0x01110013060a98807601439ef75413cf053900 (19 bytes) 17:19:39.106 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 57 └─[SecurityCCNonceReport] nonce: 0x7601439ef75413cf 17:19:39.115 SERIAL « [ACK] (0x06) 17:19:39.117 SERIAL « 0x0104011301e8 (6 bytes) 17:19:39.118 SERIAL » [ACK] (0x06) 17:19:39.120 DRIVER « [RES] [SendData] was sent: true 17:19:39.137 SERIAL « 0x0107001339000002d0 (9 bytes) 17:19:39.138 SERIAL » [ACK] (0x06) 17:19:39.139 DRIVER « [REQ] [SendData] callback id: 57 transmit status: OK 17:19:39.170 SERIAL « 0x012700040006219881ae397464588cd45acdb2def84623aeb318f5a58d368a761 (41 bytes) e04b1067a1980623d 17:19:39.171 SERIAL » [ACK] (0x06) 17:19:39.173 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: System notification status: 255 notification event: Unknown (0xfe) 17:19:39.178 SERIAL » 0x010a0013070370052e253aa6 (12 bytes) 17:19:39.178 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 58 └─[ConfigurationCCGet] parameter #: 46 17:19:39.179 CNTRLR [Node 006] [~] [Notification] System[unknown]: 254 => 254 [Endpoint 1] 17:19:39.181 CNTRLR [Node 006] [~] [Notification] interviewComplete: true [Endpoint 1] [internal] => true 17:19:39.210 SERIAL « [ACK] (0x06) 17:19:39.215 SERIAL « 0x0104011301e8 (6 bytes) 17:19:39.216 SERIAL » [ACK] (0x06) 17:19:39.218 DRIVER « [RES] [SendData] was sent: true 17:19:39.221 CNTRLR [Node 006] ProtectionCC: doing a partial interview... 17:19:39.222 CNTRLR » [Node 006] querying protection status... 17:19:39.241 SERIAL « 0x010700133a000006d7 (9 bytes) 17:19:39.241 SERIAL » [ACK] (0x06) 17:19:39.242 DRIVER « [REQ] [SendData] callback id: 58 transmit status: OK 17:19:39.325 SERIAL « 0x010b000400070570062e0100ab (13 bytes) 17:19:39.331 CNTRLR [Node 007] [~] [Configuration] 46: 0 => 0 17:19:39.331 SERIAL » [ACK] (0x06) 17:19:39.333 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 46 value size: 1 value: 0 17:19:39.337 SERIAL » 0x010a0013030370052a253ba7 (12 bytes) 17:19:39.337 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 59 └─[ConfigurationCCGet] parameter #: 42 17:19:39.338 CNTRLR « [Node 007] parameter #46 has value: 0 17:19:39.339 CNTRLR » [Node 007] querying parameter #81 value... 17:19:39.344 SERIAL « [ACK] (0x06) 17:19:39.348 SERIAL « 0x0104011301e8 (6 bytes) 17:19:39.349 SERIAL » [ACK] (0x06) 17:19:39.351 DRIVER « [RES] [SendData] was sent: true 17:19:39.416 SERIAL « 0x010700133b000007d7 (9 bytes) 17:19:39.417 SERIAL » [ACK] (0x06) 17:19:39.418 DRIVER « [REQ] [SendData] callback id: 59 transmit status: OK 17:19:39.427 SERIAL « 0x010b000400030570062a010fa4 (13 bytes) 17:19:39.432 CNTRLR [Node 003] [~] [Configuration] 42: 15 => 15 17:19:39.433 SERIAL » [ACK] (0x06) 17:19:39.434 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 15 17:19:39.440 SERIAL » 0x010a00130703700551253cdf (12 bytes) 17:19:39.442 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 60 └─[ConfigurationCCGet] parameter #: 81 17:19:39.443 CNTRLR « [Node 003] parameter #42 has value: 15 17:19:39.443 CNTRLR » [Node 003] querying parameter #43 value... 17:19:39.450 SERIAL « [ACK] (0x06) 17:19:39.452 SERIAL « 0x0104011301e8 (6 bytes) 17:19:39.453 SERIAL » [ACK] (0x06) 17:19:39.454 DRIVER « [RES] [SendData] was sent: true 17:19:39.505 SERIAL « 0x010700133c000006d1 (9 bytes) 17:19:39.505 SERIAL » [ACK] (0x06) 17:19:39.506 DRIVER « [REQ] [SendData] callback id: 60 transmit status: OK 17:19:40.215 SERIAL « 0x010b00040007057006510100d4 (13 bytes) 17:19:40.220 CNTRLR [Node 007] [~] [Configuration] 81: 0 => 0 17:19:40.221 SERIAL » [ACK] (0x06) 17:19:40.245 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 81 value size: 1 value: 0 17:19:40.266 SERIAL » 0x0109001306029840253d21 (11 bytes) 17:19:40.266 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 61 └─[SecurityCCNonceGet] 17:19:40.267 CNTRLR « [Node 007] parameter #81 has value: 0 17:19:40.268 CNTRLR » [Node 007] querying parameter #111 value... 17:19:40.291 SERIAL « 0x010c0004000306310504220aa64c (14 bytes) 17:19:40.293 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:19:40.294 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 81.6 => 272.6 [Endpoint 0] 17:19:40.295 SERIAL » [ACK] (0x06) 17:19:40.295 SERIAL « [CAN] (0x18) 17:19:40.296 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 17:19:40.306 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 272.6 17:19:40.310 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 17:19:40.311 SERIAL » [ACK] (0x06) 17:19:40.314 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  17:19:40.317 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 17:19:40.397 SERIAL » 0x0109001306029840253d21 (11 bytes) 17:19:40.398 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 61 └─[SecurityCCNonceGet] 17:19:40.400 SERIAL « [ACK] (0x06) 17:19:40.406 SERIAL « 0x0104011301e8 (6 bytes) 17:19:40.407 SERIAL » [ACK] (0x06) 17:19:40.408 DRIVER « [RES] [SendData] was sent: true 17:19:41.717 SERIAL « 0x010700133d00008355 (9 bytes) 17:19:41.717 SERIAL » [ACK] (0x06) 17:19:41.718 DRIVER « [REQ] [SendData] callback id: 61 transmit status: OK 17:19:41.739 SERIAL « 0x0110000400060a988023e58b05dd4916c4f1 (18 bytes) 17:19:41.741 SERIAL » [ACK] (0x06) 17:19:41.742 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x23e58b05dd4916c4 17:19:41.746 SERIAL » 0x01210013061a98816d0098750ad9b2a72f23b8310aa32c2327a0072f9977c6692 (35 bytes) 53e58 17:19:41.747 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 62 └─[SecurityCCCommandEncapsulation] │ nonce id: 35 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 17:19:41.751 SERIAL « [ACK] (0x06) 17:19:41.759 SERIAL « 0x0104011301e8 (6 bytes) 17:19:41.759 SERIAL » [ACK] (0x06) 17:19:41.760 DRIVER « [RES] [SendData] was sent: true 17:19:41.784 SERIAL « 0x010700133e000003d6 (9 bytes) 17:19:41.785 SERIAL » [ACK] (0x06) 17:19:41.786 DRIVER « [REQ] [SendData] callback id: 62 transmit status: OK 17:19:41.902 SERIAL « 0x0108000400060298402f (10 bytes) 17:19:41.903 SERIAL » [ACK] (0x06) 17:19:41.904 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:19:41.914 SERIAL » 0x01110013060a988097afc69d86f6d74b053f5c (19 bytes) 17:19:41.915 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 63 └─[SecurityCCNonceReport] nonce: 0x97afc69d86f6d74b 17:19:41.921 SERIAL « [ACK] (0x06) 17:19:41.923 SERIAL « 0x0104011301e8 (6 bytes) 17:19:41.924 SERIAL » [ACK] (0x06) 17:19:41.924 DRIVER « [RES] [SendData] was sent: true 17:19:41.946 SERIAL « 0x010700133f000003d7 (9 bytes) 17:19:41.946 SERIAL » [ACK] (0x06) 17:19:41.947 DRIVER « [REQ] [SendData] callback id: 63 transmit status: OK 17:19:41.976 SERIAL « 0x0121000400061b98814dae6ca174770ddf53d796b7341d6ad29749a339f0ca503 (35 bytes) 1bfb5 17:19:41.977 SERIAL » [ACK] (0x06) 17:19:41.979 CNTRLR [Node 006] [~] [Protection] local: 0 => 0 [Endpoint 1] 17:19:41.980 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ProtectionCCReport] local: Unprotected 17:19:41.992 SERIAL » 0x010a0013070370056f25409d (12 bytes) 17:19:41.993 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 64 └─[ConfigurationCCGet] parameter #: 111 17:19:41.994 CNTRLR « [Node 006] received protection status: local: Unprotected 17:19:41.995 CNTRLR [Node 006] [~] [Protection] interviewComplete: true => [Endpoint 1] [internal] true 17:19:42.033 SERIAL « [ACK] (0x06) 17:19:42.041 SERIAL « 0x0104011301e8 (6 bytes) 17:19:42.042 SERIAL » [ACK] (0x06) 17:19:42.044 DRIVER « [RES] [SendData] was sent: true 17:19:42.047 CNTRLR [Node 006] BatteryCC: doing a partial interview... [Endpoint 1] 17:19:42.048 CNTRLR » [Node 006] querying battery status... [Endpoint 1] 17:19:42.063 SERIAL « 0x0107001340000006ad (9 bytes) 17:19:42.064 SERIAL » [ACK] (0x06) 17:19:42.065 DRIVER « [REQ] [SendData] callback id: 64 transmit status: OK 17:19:42.372 SERIAL « 0x010e000400070870066f0400000e10f9 (16 bytes) 17:19:42.378 CNTRLR [Node 007] [~] [Configuration] 111: 3600 => 3600 17:19:42.379 SERIAL » [ACK] (0x06) 17:19:42.381 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 111 value size: 4 value: 3600 17:19:42.387 SERIAL » 0x010a0013030370052b2541dc (12 bytes) 17:19:42.387 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 65 └─[ConfigurationCCGet] parameter #: 43 17:19:42.389 CNTRLR « [Node 007] parameter #111 has value: 3600 17:19:42.389 CNTRLR » [Node 007] querying parameter #112 value... 17:19:42.395 SERIAL « [ACK] (0x06) 17:19:42.397 SERIAL « 0x0104011301e8 (6 bytes) 17:19:42.398 SERIAL » [ACK] (0x06) 17:19:42.400 DRIVER « [RES] [SendData] was sent: true 17:19:42.413 SERIAL « 0x0107001341000002a8 (9 bytes) 17:19:42.414 SERIAL » [ACK] (0x06) 17:19:42.415 DRIVER « [REQ] [SendData] callback id: 65 transmit status: OK 17:19:42.424 SERIAL « 0x010b000400030570062b011eb4 (13 bytes) 17:19:42.429 CNTRLR [Node 003] [~] [Configuration] 43: 30 => 30 17:19:42.430 SERIAL » [ACK] (0x06) 17:19:42.431 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 30 17:19:42.435 SERIAL » 0x010a00130703700570254280 (12 bytes) 17:19:42.436 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 66 └─[ConfigurationCCGet] parameter #: 112 17:19:42.436 CNTRLR « [Node 003] parameter #43 has value: 30 17:19:42.436 CNTRLR » [Node 003] querying parameter #45 value... 17:19:42.440 SERIAL « [ACK] (0x06) 17:19:42.445 SERIAL « 0x0104011301e8 (6 bytes) 17:19:42.446 SERIAL » [ACK] (0x06) 17:19:42.450 DRIVER « [RES] [SendData] was sent: true 17:19:42.498 SERIAL « 0x0107001342000006af (9 bytes) 17:19:42.498 SERIAL » [ACK] (0x06) 17:19:42.499 DRIVER « [REQ] [SendData] callback id: 66 transmit status: OK 17:19:42.577 SERIAL « 0x010e00040007087006700400000e10e6 (16 bytes) 17:19:42.582 CNTRLR [Node 007] [~] [Configuration] 112: 3600 => 3600 17:19:42.583 SERIAL » [ACK] (0x06) 17:19:42.584 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 112 value size: 4 value: 3600 17:19:42.590 SERIAL » 0x010900130602984025435f (11 bytes) 17:19:42.590 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 67 └─[SecurityCCNonceGet] 17:19:42.591 CNTRLR « [Node 007] parameter #112 has value: 3600 17:19:42.591 CNTRLR » [Node 007] querying parameter #113 value... 17:19:42.596 SERIAL « [ACK] (0x06) 17:19:42.601 SERIAL « 0x0104011301e8 (6 bytes) 17:19:42.602 SERIAL » [ACK] (0x06) 17:19:42.602 DRIVER « [RES] [SendData] was sent: true 17:19:42.669 SERIAL « 0x0107001343000007af (9 bytes) 17:19:42.670 SERIAL » [ACK] (0x06) 17:19:42.671 DRIVER « [REQ] [SendData] callback id: 67 transmit status: OK 17:19:42.692 SERIAL « 0x0110000400060a98807087d6faddef347250 (18 bytes) 17:19:42.693 SERIAL » [ACK] (0x06) 17:19:42.694 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x7087d6faddef3472 17:19:42.698 SERIAL » 0x01210013061a988110ab56874887844389fc6755a5aff17038a8a5c4ee3cd7322 (35 bytes) 544c1 17:19:42.699 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 68 └─[SecurityCCCommandEncapsulation] │ nonce id: 112 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BatteryCCGet] 17:19:42.702 SERIAL « [ACK] (0x06) 17:19:42.709 SERIAL « 0x0104011301e8 (6 bytes) 17:19:42.710 SERIAL » [ACK] (0x06) 17:19:42.710 DRIVER « [RES] [SendData] was sent: true 17:19:42.739 SERIAL « 0x0107001344000003ac (9 bytes) 17:19:42.740 SERIAL » [ACK] (0x06) 17:19:42.741 DRIVER « [REQ] [SendData] callback id: 68 transmit status: OK 17:19:42.821 SERIAL « 0x0108000400060298402f (10 bytes) 17:19:42.822 SERIAL » [ACK] (0x06) 17:19:42.823 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:19:42.829 SERIAL » 0x01110013060a9880f1933611b1f95e340545ce (19 bytes) 17:19:42.829 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 69 └─[SecurityCCNonceReport] nonce: 0xf1933611b1f95e34 17:19:42.832 SERIAL « [ACK] (0x06) 17:19:42.838 SERIAL « 0x0104011301e8 (6 bytes) 17:19:42.839 SERIAL » [ACK] (0x06) 17:19:42.840 DRIVER « [RES] [SendData] was sent: true 17:19:42.860 SERIAL « 0x0107001345000003ad (9 bytes) 17:19:42.860 SERIAL » [ACK] (0x06) 17:19:42.861 DRIVER « [REQ] [SendData] callback id: 69 transmit status: OK 17:19:42.890 SERIAL « 0x0121000400061b9881c03da333148fb185184ed2715dea4e9cf1c96bc8bb0bdfe (35 bytes) 1841d 17:19:42.891 SERIAL » [ACK] (0x06) 17:19:42.893 CNTRLR [Node 006] [~] [Battery] level: 11 => 11 [Endpoint 1] 17:19:42.893 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 1] 17:19:42.894 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BatteryCCReport] level: 11 is low: false 17:19:42.898 SERIAL » 0x010a00130703700571254685 (12 bytes) 17:19:42.899 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 70 └─[ConfigurationCCGet] parameter #: 113 17:19:42.900 CNTRLR « [Node 006] received response for battery information: [Endpoint 1] level: 11 17:19:42.900 CNTRLR [Node 006] [~] [Battery] interviewComplete: true => tr [Endpoint 1] [internal] ue 17:19:42.928 SERIAL « [ACK] (0x06) 17:19:42.932 SERIAL « 0x0104011301e8 (6 bytes) 17:19:42.933 SERIAL » [ACK] (0x06) 17:19:42.934 DRIVER « [RES] [SendData] was sent: true 17:19:42.938 CNTRLR [Node 006] ClockCC: doing a partial interview... 17:19:42.938 CNTRLR » [Node 006] requesting current clock setting... 17:19:42.961 SERIAL « 0x0107001346000006ab (9 bytes) 17:19:42.962 SERIAL » [ACK] (0x06) 17:19:42.963 DRIVER « [REQ] [SendData] callback id: 70 transmit status: OK 17:19:43.047 SERIAL « 0x010e00040007087006710400000e10e7 (16 bytes) 17:19:43.052 CNTRLR [Node 007] [~] [Configuration] 113: 3600 => 3600 17:19:43.053 SERIAL » [ACK] (0x06) 17:19:43.054 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 113 value size: 4 value: 3600 17:19:43.058 SERIAL » 0x010a0013030370052d2547dc (12 bytes) 17:19:43.059 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 71 └─[ConfigurationCCGet] parameter #: 45 17:19:43.060 CNTRLR « [Node 007] parameter #113 has value: 3600 17:19:43.060 CNTRLR » [Node 007] querying parameter #201 value... 17:19:43.064 SERIAL « [ACK] (0x06) 17:19:43.069 SERIAL « 0x0104011301e8 (6 bytes) 17:19:43.070 SERIAL » [ACK] (0x06) 17:19:43.072 DRIVER « [RES] [SendData] was sent: true 17:19:43.136 SERIAL « 0x0107001347000007ab (9 bytes) 17:19:43.137 SERIAL » [ACK] (0x06) 17:19:43.138 DRIVER « [REQ] [SendData] callback id: 71 transmit status: OK 17:19:43.146 SERIAL « 0x010b000400030570062d010aa6 (13 bytes) 17:19:43.152 CNTRLR [Node 003] [~] [Configuration] 45: 10 => 10 17:19:43.153 SERIAL » [ACK] (0x06) 17:19:43.154 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 45 value size: 1 value: 10 17:19:43.166 SERIAL » 0x010a001307037005c9254833 (12 bytes) 17:19:43.167 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 72 └─[ConfigurationCCGet] parameter #: 201 17:19:43.167 CNTRLR « [Node 003] parameter #45 has value: 10 17:19:43.167 CNTRLR » [Node 003] querying parameter #47 value... 17:19:43.707 SERIAL « [ACK] (0x06) 17:19:43.709 SERIAL « 0x0104011301e8 (6 bytes) 17:19:43.710 SERIAL » [ACK] (0x06) 17:19:43.711 DRIVER « [RES] [SendData] was sent: true 17:19:43.717 SERIAL « 0x0107001348000005a6 (9 bytes) 17:19:43.718 SERIAL » [ACK] (0x06) 17:19:43.721 DRIVER « [REQ] [SendData] callback id: 72 transmit status: OK 17:19:43.726 SERIAL « 0x010c00040007067006c90200014a (14 bytes) 17:19:43.732 CNTRLR [Node 007] [~] [Configuration] 201[255]: 1 => 1 17:19:43.733 CNTRLR [Node 007] [~] [Configuration] 201[65280]: 0 => 0 17:19:43.734 SERIAL » [ACK] (0x06) 17:19:43.735 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 201 value size: 2 value: 1 17:19:43.741 SERIAL » 0x0109001306029840254955 (11 bytes) 17:19:43.741 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 73 └─[SecurityCCNonceGet] 17:19:43.742 CNTRLR « [Node 007] parameter #201 has value: 1 17:19:43.743 CNTRLR » [Node 007] querying parameter #202 value... 17:19:43.753 SERIAL « [ACK] (0x06) 17:19:43.754 SERIAL « 0x0104011301e8 (6 bytes) 17:19:43.755 SERIAL » [ACK] (0x06) 17:19:43.756 DRIVER « [RES] [SendData] was sent: true 17:19:43.771 SERIAL « 0x0107001349000003a1 (9 bytes) 17:19:43.772 SERIAL » [ACK] (0x06) 17:19:43.774 DRIVER « [REQ] [SendData] callback id: 73 transmit status: OK 17:19:43.793 SERIAL « 0x0110000400060a9880bbe8dcecc8f6d40670 (18 bytes) 17:19:43.794 SERIAL » [ACK] (0x06) 17:19:43.795 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xbbe8dcecc8f6d406 17:19:43.800 SERIAL » 0x01210013061a9881b3ef726dfad533ec0afe59a848fcc0bb9e7e019faa3f9b982 (35 bytes) 54a36 17:19:43.801 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 74 └─[SecurityCCCommandEncapsulation] │ nonce id: 187 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ClockCCGet] 17:19:43.804 SERIAL « [ACK] (0x06) 17:19:43.812 SERIAL « 0x0104011301e8 (6 bytes) 17:19:43.812 SERIAL » [ACK] (0x06) 17:19:43.813 DRIVER « [RES] [SendData] was sent: true 17:19:43.837 SERIAL « 0x010700134a000003a2 (9 bytes) 17:19:43.837 SERIAL » [ACK] (0x06) 17:19:43.838 DRIVER « [REQ] [SendData] callback id: 74 transmit status: OK 17:19:43.928 SERIAL « 0x0108000400060298402f (10 bytes) 17:19:43.928 SERIAL » [ACK] (0x06) 17:19:43.930 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:19:43.935 SERIAL » 0x01110013060a98809c200959c4b07caf054bec (19 bytes) 17:19:43.936 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 75 └─[SecurityCCNonceReport] nonce: 0x9c200959c4b07caf 17:19:43.938 SERIAL « [ACK] (0x06) 17:19:43.944 SERIAL « 0x0104011301e8 (6 bytes) 17:19:43.945 SERIAL » [ACK] (0x06) 17:19:43.946 DRIVER « [RES] [SendData] was sent: true 17:19:43.966 SERIAL « 0x010700134b000002a2 (9 bytes) 17:19:43.968 SERIAL » [ACK] (0x06) 17:19:43.969 DRIVER « [REQ] [SendData] callback id: 75 transmit status: OK 17:19:44.001 SERIAL « 0x0122000400061c9881b46e2caf5c80ca45cdb146e47b155351179c1e2c03cce66 (36 bytes) 10534a2 17:19:44.003 SERIAL » [ACK] (0x06) 17:19:44.005 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ClockCCReport] clock setting: Wednesday, 18:12 17:19:44.009 SERIAL » 0x010a001307037005ca254c34 (12 bytes) 17:19:44.010 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 76 └─[ConfigurationCCGet] parameter #: 202 17:19:44.010 CNTRLR « [Node 006] received current clock setting: Wednesday, 18:12 17:19:44.011 CNTRLR [Node 006] [~] [Clock] interviewComplete: true => true [Endpoint 1] [internal] 17:19:44.037 SERIAL « [ACK] (0x06) 17:19:44.041 SERIAL « 0x0104011301e8 (6 bytes) 17:19:44.042 SERIAL » [ACK] (0x06) 17:19:44.043 DRIVER « [RES] [SendData] was sent: true 17:19:44.048 CNTRLR [Node 006] ZWavePlusCC: doing a partial interview... [Endpoint 2] 17:19:44.049 CNTRLR [Node 006] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 17:19:44.049 CNTRLR [Node 006] MultilevelSensorCC: doing a partial interview... [Endpoint 2] 17:19:44.050 CNTRLR » [Node 006] querying Air temperature sensor reading... [Endpoint 2] 17:19:44.072 SERIAL « 0x010700134c000006a1 (9 bytes) 17:19:44.073 SERIAL » [ACK] (0x06) 17:19:44.074 DRIVER « [REQ] [SendData] callback id: 76 transmit status: OK 17:19:44.157 SERIAL « 0x010b00040007057006ca01004f (13 bytes) 17:19:44.164 CNTRLR [Node 007] [~] [Configuration] 202: 0 => 0 17:19:44.165 SERIAL » [ACK] (0x06) 17:19:44.166 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 202 value size: 1 value: 0 17:19:44.171 SERIAL » 0x010a0013030370052f254dd4 (12 bytes) 17:19:44.171 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 77 └─[ConfigurationCCGet] parameter #: 47 17:19:44.172 CNTRLR « [Node 007] parameter #202 has value: 0 17:19:44.172 CNTRLR » [Node 007] querying parameter #203 value... 17:19:44.180 SERIAL « [ACK] (0x06) 17:19:44.182 SERIAL « 0x0104011301e8 (6 bytes) 17:19:44.182 SERIAL » [ACK] (0x06) 17:19:44.183 DRIVER « [RES] [SendData] was sent: true 17:19:44.247 SERIAL « 0x010700134d000007a1 (9 bytes) 17:19:44.248 SERIAL » [ACK] (0x06) 17:19:44.248 DRIVER « [REQ] [SendData] callback id: 77 transmit status: OK 17:19:44.261 SERIAL « 0x010c000400030670062f020e10b7 (14 bytes) 17:19:44.268 CNTRLR [Node 003] [~] [Configuration] 47: 3600 => 3600 17:19:44.269 SERIAL » [ACK] (0x06) 17:19:44.270 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 47 value size: 2 value: 3600 17:19:44.277 SERIAL » 0x010a001307037005cb254e37 (12 bytes) 17:19:44.278 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 78 └─[ConfigurationCCGet] parameter #: 203 17:19:44.279 CNTRLR « [Node 003] parameter #47 has value: 3600 17:19:44.279 CNTRLR » [Node 003] querying parameter #49 value... 17:19:44.284 SERIAL « [ACK] (0x06) 17:19:44.287 SERIAL « 0x0104011301e8 (6 bytes) 17:19:44.288 SERIAL » [ACK] (0x06) 17:19:44.289 DRIVER « [RES] [SendData] was sent: true 17:19:44.341 SERIAL « 0x010700134e000006a3 (9 bytes) 17:19:44.342 SERIAL » [ACK] (0x06) 17:19:44.343 DRIVER « [REQ] [SendData] callback id: 78 transmit status: OK 17:19:44.426 SERIAL « 0x010c00040007067006cb02000049 (14 bytes) 17:19:44.432 CNTRLR [Node 007] [~] [Configuration] 203: 0 => 0 17:19:44.433 SERIAL » [ACK] (0x06) 17:19:44.434 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 203 value size: 2 value: 0 17:19:44.441 SERIAL » 0x0109001306029840254f53 (11 bytes) 17:19:44.441 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 79 └─[SecurityCCNonceGet] 17:19:44.443 CNTRLR « [Node 007] parameter #203 has value: 0 17:19:44.443 CNTRLR » [Node 007] querying parameter #204 value... 17:19:44.447 SERIAL « [ACK] (0x06) 17:19:44.450 SERIAL « 0x0104011301e8 (6 bytes) 17:19:44.451 SERIAL » [ACK] (0x06) 17:19:44.451 DRIVER « [RES] [SendData] was sent: true 17:19:44.519 SERIAL « 0x010700134f000007a3 (9 bytes) 17:19:44.520 SERIAL » [ACK] (0x06) 17:19:44.520 DRIVER « [REQ] [SendData] callback id: 79 transmit status: OK 17:19:44.541 SERIAL « 0x0110000400060a988041657c1a8743082455 (18 bytes) 17:19:44.542 SERIAL » [ACK] (0x06) 17:19:44.542 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x41657c1a87430824 17:19:44.547 SERIAL » 0x01230013061c98811f4013b420f8b9cd40095a46fe3a099770419c8ec3f750e01 (37 bytes) 8dd255080 17:19:44.548 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 80 └─[SecurityCCCommandEncapsulation] │ nonce id: 65 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 17:19:44.551 SERIAL « [ACK] (0x06) 17:19:44.558 SERIAL « 0x0104011301e8 (6 bytes) 17:19:44.559 SERIAL » [ACK] (0x06) 17:19:44.560 DRIVER « [RES] [SendData] was sent: true 17:19:44.584 SERIAL « 0x0107001350000003b8 (9 bytes) 17:19:44.585 SERIAL » [ACK] (0x06) 17:19:44.586 DRIVER « [REQ] [SendData] callback id: 80 transmit status: OK 17:19:44.676 SERIAL « 0x0108000400060298402f (10 bytes) 17:19:44.677 SERIAL » [ACK] (0x06) 17:19:44.678 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:19:44.684 SERIAL » 0x01110013060a9880b60b070a12b000af055100 (19 bytes) 17:19:44.685 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 81 └─[SecurityCCNonceReport] nonce: 0xb60b070a12b000af 17:19:44.687 SERIAL « [ACK] (0x06) 17:19:44.693 SERIAL « 0x0104011301e8 (6 bytes) 17:19:44.694 SERIAL » [ACK] (0x06) 17:19:44.695 DRIVER « [RES] [SendData] was sent: true 17:19:44.715 SERIAL « 0x0107001351000003b9 (9 bytes) 17:19:44.716 SERIAL » [ACK] (0x06) 17:19:44.717 DRIVER « [REQ] [SendData] callback id: 81 transmit status: OK 17:19:44.747 SERIAL « 0x0124000400061e98810894e39d4a93bc910b66506a634a08c10db937b67dcfbf7 (38 bytes) fb29825586f 17:19:44.749 SERIAL » [ACK] (0x06) 17:19:44.752 CNTRLR [Node 006] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 17:19:44.753 CNTRLR [Node 006] [~] [Multilevel Sensor] Air temperature: 18.8 => 18.7 [Endpoint 2] 17:19:44.765 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.7 17:19:44.770 SERIAL » 0x010a001307037005cc25522c (12 bytes) 17:19:44.770 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 82 └─[ConfigurationCCGet] parameter #: 204 17:19:44.772 CNTRLR « [Node 006] received current Air temperature sensor reading: 18.7 [Endpoint 2] °C 17:19:44.772 CNTRLR [Node 006] [~] [Multilevel Sensor] interviewComplete: [Endpoint 2] [internal] true => true 17:19:44.803 SERIAL « [ACK] (0x06) 17:19:44.811 SERIAL « 0x0104011301e8 (6 bytes) 17:19:44.812 SERIAL » [ACK] (0x06) 17:19:44.813 DRIVER « [RES] [SendData] was sent: true 17:19:44.821 CNTRLR [Node 006] NotificationCC: doing a partial interview... [Endpoint 2] 17:19:44.821 CNTRLR » [Node 006] querying notification status for Power Management... [Endpoint 2] 17:19:44.833 SERIAL « 0x0107001352000006bf (9 bytes) 17:19:44.834 SERIAL » [ACK] (0x06) 17:19:44.835 DRIVER « [REQ] [SendData] callback id: 82 transmit status: OK 17:19:44.915 SERIAL « 0x010b00040007057006cc010049 (13 bytes) 17:19:44.922 CNTRLR [Node 007] [~] [Configuration] 204: 0 => 0 17:19:44.923 SERIAL » [ACK] (0x06) 17:19:44.925 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 204 value size: 1 value: 0 17:19:44.929 SERIAL » 0x010a001303037005312553d4 (12 bytes) 17:19:44.930 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 83 └─[ConfigurationCCGet] parameter #: 49 17:19:44.931 CNTRLR « [Node 007] parameter #204 has value: 0 17:19:44.932 CNTRLR » [Node 007] querying parameter #252 value... 17:19:44.937 SERIAL « [ACK] (0x06) 17:19:44.941 SERIAL « 0x0104011301e8 (6 bytes) 17:19:44.941 SERIAL » [ACK] (0x06) 17:19:44.943 DRIVER « [RES] [SendData] was sent: true 17:19:45.006 SERIAL « 0x0107001353000007bf (9 bytes) 17:19:45.006 SERIAL » [ACK] (0x06) 17:19:45.007 DRIVER « [REQ] [SendData] callback id: 83 transmit status: OK 17:19:45.017 SERIAL « 0x010b00040003057006310100b0 (13 bytes) 17:19:45.029 CNTRLR [Node 003] [~] [Configuration] 49: 0 => 0 17:19:45.030 SERIAL » [ACK] (0x06) 17:19:45.032 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 49 value size: 1 value: 0 17:19:45.037 SERIAL » 0x010a001307037005fc25541a (12 bytes) 17:19:45.037 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 84 └─[ConfigurationCCGet] parameter #: 252 17:19:45.038 CNTRLR « [Node 003] parameter #49 has value: 0 17:19:45.039 CNTRLR » [Node 003] querying parameter #50 value... 17:19:45.043 SERIAL « [ACK] (0x06) 17:19:45.046 SERIAL « 0x0104011301e8 (6 bytes) 17:19:45.047 SERIAL » [ACK] (0x06) 17:19:45.048 DRIVER « [RES] [SendData] was sent: true 17:19:45.099 SERIAL « 0x0107001354000005ba (9 bytes) 17:19:45.100 SERIAL » [ACK] (0x06) 17:19:45.101 DRIVER « [REQ] [SendData] callback id: 84 transmit status: OK 17:19:45.185 SERIAL « 0x010b00040007057006fc010079 (13 bytes) 17:19:45.193 CNTRLR [Node 007] [~] [Configuration] 252: 0 => 0 17:19:45.194 SERIAL » [ACK] (0x06) 17:19:45.196 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 252 value size: 1 value: 0 17:19:45.201 SERIAL » 0x0109001306029840255549 (11 bytes) 17:19:45.202 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 85 └─[SecurityCCNonceGet] 17:19:45.203 CNTRLR « [Node 007] parameter #252 has value: 0 17:19:45.203 CNTRLR » [Node 007] querying parameter #101 value... 17:19:45.208 SERIAL « [ACK] (0x06) 17:19:45.214 SERIAL « 0x0104011301e8 (6 bytes) 17:19:45.215 SERIAL » [ACK] (0x06) 17:19:45.217 DRIVER « [RES] [SendData] was sent: true 17:19:45.279 SERIAL « 0x0107001355000007b9 (9 bytes) 17:19:45.280 SERIAL » [ACK] (0x06) 17:19:45.283 DRIVER « [REQ] [SendData] callback id: 85 transmit status: OK 17:19:45.302 SERIAL « 0x0110000400060a98804a1905937e3b21643a (18 bytes) 17:19:45.303 SERIAL » [ACK] (0x06) 17:19:45.303 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x4a1905937e3b2164 17:19:45.308 SERIAL » 0x01240013061d9881ccb8d74d16804e2f5e7fc983c030b38a2cb94acd9c2ede272 (38 bytes) 0963a2556d7 17:19:45.309 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 86 └─[SecurityCCCommandEncapsulation] │ nonce id: 74 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: Power Management 17:19:45.313 SERIAL « [ACK] (0x06) 17:19:45.320 SERIAL « 0x0104011301e8 (6 bytes) 17:19:45.320 SERIAL » [ACK] (0x06) 17:19:45.321 DRIVER « [RES] [SendData] was sent: true 17:19:45.347 SERIAL « 0x0107001356000003be (9 bytes) 17:19:45.348 SERIAL » [ACK] (0x06) 17:19:45.348 DRIVER « [REQ] [SendData] callback id: 86 transmit status: OK 17:19:45.370 SERIAL « 0x0108000400060298402f (10 bytes) 17:19:45.371 SERIAL » [ACK] (0x06) 17:19:45.372 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:19:45.380 SERIAL » 0x01110013060a98806d19ceb02cd6858205574c (19 bytes) 17:19:45.380 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 87 └─[SecurityCCNonceReport] nonce: 0x6d19ceb02cd68582 17:19:45.383 SERIAL « [ACK] (0x06) 17:19:45.389 SERIAL « 0x0104011301e8 (6 bytes) 17:19:45.390 SERIAL » [ACK] (0x06) 17:19:45.391 DRIVER « [RES] [SendData] was sent: true 17:19:45.411 SERIAL « 0x0107001357000003bf (9 bytes) 17:19:45.411 SERIAL » [ACK] (0x06) 17:19:45.412 DRIVER « [REQ] [SendData] callback id: 87 transmit status: OK 17:19:45.445 SERIAL « 0x012700040006219881362b8dc28c03ff9fa8dad9c490951018c113e056a0716d7 (41 bytes) 6cfdfe30a919f8aee 17:19:45.446 SERIAL » [ACK] (0x06) 17:19:45.448 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 17:19:45.452 SERIAL » 0x010a0013070370056525588f (12 bytes) 17:19:45.452 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 88 └─[ConfigurationCCGet] parameter #: 101 17:19:45.453 CNTRLR [Node 006] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 2] 54 17:19:45.454 CNTRLR » [Node 006] querying notification status for System... [Endpoint 2] 17:19:45.459 SERIAL « [ACK] (0x06) 17:19:45.461 SERIAL « 0x0104011301e8 (6 bytes) 17:19:45.461 SERIAL » [ACK] (0x06) 17:19:45.462 DRIVER « [RES] [SendData] was sent: true 17:19:45.515 SERIAL « 0x0107001358000006b5 (9 bytes) 17:19:45.515 SERIAL » [ACK] (0x06) 17:19:45.516 DRIVER « [REQ] [SendData] callback id: 88 transmit status: OK 17:19:46.267 SERIAL « 0x010e000400070870066504000000f11c (16 bytes) 17:19:46.276 CNTRLR [Node 007] [~] [Configuration] 101[1]: 1 => 1 17:19:46.278 CNTRLR [Node 007] [~] [Configuration] 101[16]: 1 => 1 17:19:46.279 CNTRLR [Node 007] [~] [Configuration] 101[32]: 1 => 1 17:19:46.280 CNTRLR [Node 007] [~] [Configuration] 101[64]: 1 => 1 17:19:46.281 CNTRLR [Node 007] [~] [Configuration] 101[128]: 1 => 1 17:19:46.282 SERIAL » [ACK] (0x06) 17:19:46.284 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 101 value size: 4 value: 241 17:19:46.288 SERIAL » 0x010a001303037005322559dd (12 bytes) 17:19:46.288 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 89 └─[ConfigurationCCGet] parameter #: 50 17:19:46.289 CNTRLR « [Node 007] parameter #101 has value: 241 17:19:46.289 CNTRLR » [Node 007] querying parameter #102 value... 17:19:46.295 SERIAL « [ACK] (0x06) 17:19:46.300 SERIAL « 0x0104011301e8 (6 bytes) 17:19:46.301 SERIAL » [ACK] (0x06) 17:19:46.303 DRIVER « [RES] [SendData] was sent: true 17:19:46.314 SERIAL « 0x0107001359000002b0 (9 bytes) 17:19:46.316 SERIAL » [ACK] (0x06) 17:19:46.317 DRIVER « [REQ] [SendData] callback id: 89 transmit status: OK 17:19:46.326 SERIAL « 0x010c000400030670063202012c99 (14 bytes) 17:19:46.334 CNTRLR [Node 003] [~] [Configuration] 50: 300 => 300 17:19:46.335 SERIAL » [ACK] (0x06) 17:19:46.336 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 2 value: 300 17:19:46.340 SERIAL » 0x010a00130703700566255a8e (12 bytes) 17:19:46.340 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 90 └─[ConfigurationCCGet] parameter #: 102 17:19:46.341 CNTRLR « [Node 003] parameter #50 has value: 300 17:19:46.341 CNTRLR » [Node 003] querying parameter #51 value... 17:19:46.346 SERIAL « [ACK] (0x06) 17:19:46.349 SERIAL « 0x0104011301e8 (6 bytes) 17:19:46.350 SERIAL » [ACK] (0x06) 17:19:46.350 DRIVER « [RES] [SendData] was sent: true 17:19:46.406 SERIAL « 0x010700135a000006b7 (9 bytes) 17:19:46.407 SERIAL » [ACK] (0x06) 17:19:46.408 DRIVER « [REQ] [SendData] callback id: 90 transmit status: OK 17:19:46.487 SERIAL « 0x010e00040007087006660400000000ee (16 bytes) 17:19:46.493 CNTRLR [Node 007] [~] [Configuration] 102[1]: 0 => 0 17:19:46.495 CNTRLR [Node 007] [~] [Configuration] 102[16]: 0 => 0 17:19:46.496 CNTRLR [Node 007] [~] [Configuration] 102[32]: 0 => 0 17:19:46.498 CNTRLR [Node 007] [~] [Configuration] 102[64]: 0 => 0 17:19:46.499 CNTRLR [Node 007] [~] [Configuration] 102[128]: 0 => 0 17:19:46.500 SERIAL » [ACK] (0x06) 17:19:46.501 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 102 value size: 4 value: 0 17:19:46.514 SERIAL » 0x0109001306029840255b47 (11 bytes) 17:19:46.515 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 91 └─[SecurityCCNonceGet] 17:19:46.516 CNTRLR « [Node 007] parameter #102 has value: 0 17:19:46.516 CNTRLR » [Node 007] querying parameter #103 value... 17:19:46.520 SERIAL « [ACK] (0x06) 17:19:46.528 SERIAL « 0x0104011301e8 (6 bytes) 17:19:46.529 SERIAL » [ACK] (0x06) 17:19:46.532 DRIVER « [RES] [SendData] was sent: true 17:19:46.555 SERIAL « 0x01090004001e03300300dc (11 bytes) 17:19:46.556 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:19:46.557 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:19:46.557 SERIAL » [ACK] (0x06) 17:19:46.559 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:19:46.608 SERIAL « 0x010700135b000009b9 (9 bytes) 17:19:46.609 SERIAL » [ACK] (0x06) 17:19:46.610 DRIVER « [REQ] [SendData] callback id: 91 transmit status: OK 17:19:46.630 SERIAL « 0x0110000400060a98809c49959ad890e254db (18 bytes) 17:19:46.631 SERIAL » [ACK] (0x06) 17:19:46.632 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x9c49959ad890e254 17:19:46.636 SERIAL » 0x01240013061d9881b0efb1966fc87477079afaa2e4b4186302b69cae825114d4f (38 bytes) 8c295255cbb 17:19:46.637 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 92 └─[SecurityCCCommandEncapsulation] │ nonce id: 156 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 17:19:46.640 SERIAL « [ACK] (0x06) 17:19:46.648 SERIAL « 0x0104011301e8 (6 bytes) 17:19:46.648 SERIAL » [ACK] (0x06) 17:19:46.649 DRIVER « [RES] [SendData] was sent: true 17:19:46.673 SERIAL « 0x010700135c000003b4 (9 bytes) 17:19:46.674 SERIAL » [ACK] (0x06) 17:19:46.675 DRIVER « [REQ] [SendData] callback id: 92 transmit status: OK 17:19:46.867 SERIAL « 0x01090004001e03200100ce (11 bytes) 17:19:46.868 SERIAL » [ACK] (0x06) 17:19:46.870 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:19:46.874 CNTRLR [Node 030] treating BasicCC Set as a report 17:19:46.875 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:19:48.279 CNTRLR [Node 006] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 17:19:48.791 SERIAL » 0x0109001306029840255d41 (11 bytes) 17:19:48.792 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 93 └─[SecurityCCNonceGet] 17:19:48.795 SERIAL « [ACK] (0x06) 17:19:48.801 SERIAL « 0x0104011301e8 (6 bytes) 17:19:48.802 SERIAL » [ACK] (0x06) 17:19:48.803 DRIVER « [RES] [SendData] was sent: true 17:19:50.111 SERIAL « 0x010700135d00008432 (9 bytes) 17:19:50.112 SERIAL » [ACK] (0x06) 17:19:50.112 DRIVER « [REQ] [SendData] callback id: 93 transmit status: OK 17:19:50.133 SERIAL « 0x0110000400060a9880c0b323fa8f50191685 (18 bytes) 17:19:50.134 SERIAL » [ACK] (0x06) 17:19:50.135 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xc0b323fa8f501916 17:19:50.140 SERIAL » 0x01240013061d9881fe515ac11771c29e877fd1876776fa401448c0fb5634c2ae8 (38 bytes) d9173255cbe 17:19:50.141 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 92 └─[SecurityCCCommandEncapsulation] │ nonce id: 192 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 17:19:50.145 SERIAL « [ACK] (0x06) 17:19:50.152 SERIAL « 0x0104011301e8 (6 bytes) 17:19:50.152 SERIAL » [ACK] (0x06) 17:19:50.153 DRIVER « [RES] [SendData] was sent: true 17:19:50.178 SERIAL « 0x010700135c000003b4 (9 bytes) 17:19:50.179 SERIAL » [ACK] (0x06) 17:19:50.179 DRIVER « [REQ] [SendData] callback id: 92 transmit status: OK 17:19:51.783 CNTRLR [Node 006] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 17:19:52.288 SERIAL » 0x0109001306029840255e42 (11 bytes) 17:19:52.289 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 94 └─[SecurityCCNonceGet] 17:19:52.291 SERIAL « [ACK] (0x06) 17:19:52.297 SERIAL « 0x0104011301e8 (6 bytes) 17:19:52.298 SERIAL » [ACK] (0x06) 17:19:52.298 DRIVER « [RES] [SendData] was sent: true 17:19:53.563 SERIAL « 0x010700135e00007fca (9 bytes) 17:19:53.564 SERIAL » [ACK] (0x06) 17:19:53.565 DRIVER « [REQ] [SendData] callback id: 94 transmit status: OK 17:19:53.585 SERIAL « 0x0110000400060a988005a05b5fd361c1d1fc (18 bytes) 17:19:53.587 SERIAL » [ACK] (0x06) 17:19:53.588 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x05a05b5fd361c1d1 17:19:53.597 SERIAL » 0x01240013061d98812cc9d793c7429c6b9bb38f83d04b7d6813c905d9dcac0ee52 (38 bytes) ac023255c9e 17:19:53.598 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 92 └─[SecurityCCCommandEncapsulation] │ nonce id: 5 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 17:19:53.602 SERIAL « [ACK] (0x06) 17:19:53.609 SERIAL « 0x0104011301e8 (6 bytes) 17:19:53.610 SERIAL » [ACK] (0x06) 17:19:53.612 DRIVER « [RES] [SendData] was sent: true 17:19:53.635 SERIAL « 0x010700135c000003b4 (9 bytes) 17:19:53.636 SERIAL » [ACK] (0x06) 17:19:53.636 DRIVER « [REQ] [SendData] callback id: 92 transmit status: OK 17:19:55.244 SERIAL » 0x010a00130703700567255f8a (12 bytes) 17:19:55.245 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 95 └─[ConfigurationCCGet] parameter #: 103 17:19:55.246 CNTRLR [Node 006] querying notification status for System timed out - sk [Endpoint 2] ipping because it is not critical... 17:19:55.247 CNTRLR [Node 006] [~] [Notification] interviewComplete: true [Endpoint 2] [internal] => true 17:19:55.276 SERIAL « [ACK] (0x06) 17:19:55.280 SERIAL « 0x0104011301e8 (6 bytes) 17:19:55.281 SERIAL » [ACK] (0x06) 17:19:55.282 DRIVER « [RES] [SendData] was sent: true 17:19:55.284 CNTRLR [Node 006] BatteryCC: doing a partial interview... [Endpoint 2] 17:19:55.285 CNTRLR » [Node 006] querying battery status... [Endpoint 2] 17:19:55.308 SERIAL « 0x010700135f000006b2 (9 bytes) 17:19:55.308 SERIAL » [ACK] (0x06) 17:19:55.309 DRIVER « [REQ] [SendData] callback id: 95 transmit status: OK 17:19:55.386 SERIAL « 0x010e00040007087006670400000000ef (16 bytes) 17:19:55.393 CNTRLR [Node 007] [~] [Configuration] 103[1]: 0 => 0 17:19:55.394 CNTRLR [Node 007] [~] [Configuration] 103[16]: 0 => 0 17:19:55.395 CNTRLR [Node 007] [~] [Configuration] 103[32]: 0 => 0 17:19:55.396 CNTRLR [Node 007] [~] [Configuration] 103[64]: 0 => 0 17:19:55.397 CNTRLR [Node 007] [~] [Configuration] 103[128]: 0 => 0 17:19:55.398 SERIAL » [ACK] (0x06) 17:19:55.399 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 103 value size: 4 value: 0 17:19:55.403 SERIAL » 0x010a001303037005332560e5 (12 bytes) 17:19:55.404 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 96 └─[ConfigurationCCGet] parameter #: 51 17:19:55.404 CNTRLR « [Node 007] parameter #103 has value: 0 17:19:55.405 CNTRLR » [Node 007] querying parameter #41 value... 17:19:55.409 SERIAL « [ACK] (0x06) 17:19:55.426 SERIAL « 0x0104011301e8 (6 bytes) 17:19:55.426 SERIAL » [ACK] (0x06) 17:19:55.428 DRIVER « [RES] [SendData] was sent: true 17:19:55.476 SERIAL « 0x01070013600000078c (9 bytes) 17:19:55.476 SERIAL » [ACK] (0x06) 17:19:55.477 DRIVER « [REQ] [SendData] callback id: 96 transmit status: OK 17:19:55.487 SERIAL « 0x010c00040003067006330201f440 (14 bytes) 17:19:55.493 CNTRLR [Node 003] [~] [Configuration] 51: 500 => 500 17:19:55.494 SERIAL » [ACK] (0x06) 17:19:55.495 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 51 value size: 2 value: 500 17:19:55.498 SERIAL » 0x010a001307037005292561fa (12 bytes) 17:19:55.499 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 97 └─[ConfigurationCCGet] parameter #: 41 17:19:55.499 CNTRLR « [Node 003] parameter #51 has value: 500 17:19:55.500 CNTRLR » [Node 003] querying parameter #52 value... 17:19:55.503 SERIAL « [ACK] (0x06) 17:19:55.508 SERIAL « 0x0104011301e8 (6 bytes) 17:19:55.509 SERIAL » [ACK] (0x06) 17:19:55.510 DRIVER « [RES] [SendData] was sent: true 17:19:55.561 SERIAL « 0x01070013610000068c (9 bytes) 17:19:55.562 SERIAL » [ACK] (0x06) 17:19:55.562 DRIVER « [REQ] [SendData] callback id: 97 transmit status: OK 17:19:55.646 SERIAL « 0x010d000400070770062903001401bf (15 bytes) 17:19:55.676 CNTRLR [Node 007] [~] [Configuration] 41[15]: 1 => 1 17:19:55.678 CNTRLR [Node 007] [~] [Configuration] 41[16776960]: 20 => 20 17:19:55.679 SERIAL » [ACK] (0x06) 17:19:55.681 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 41 value size: 3 value: 5121 17:19:55.691 SERIAL » 0x010900130602984025627e (11 bytes) 17:19:55.692 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 98 └─[SecurityCCNonceGet] 17:19:55.693 CNTRLR « [Node 007] parameter #41 has value: 5121 17:19:55.694 CNTRLR [Node 007] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:19:55.757 SERIAL « [ACK] (0x06) 17:19:55.763 SERIAL « 0x0104011301e8 (6 bytes) 17:19:55.764 SERIAL » [ACK] (0x06) 17:19:55.766 DRIVER « [RES] [SendData] was sent: true 17:19:55.769 CNTRLR [Node 007] AssociationCC: doing a partial interview... 17:19:55.770 CNTRLR » [Node 007] querying association group #1... 17:19:56.999 SERIAL « 0x01070013620000820b (9 bytes) 17:19:57.000 SERIAL » [ACK] (0x06) 17:19:57.001 DRIVER « [REQ] [SendData] callback id: 98 transmit status: OK 17:19:57.020 SERIAL « 0x0110000400060a988079a79f8edd68479755 (18 bytes) 17:19:57.021 SERIAL » [ACK] (0x06) 17:19:57.022 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x79a79f8edd684797 17:19:57.030 SERIAL » 0x01210013061a9881b4026c5da6ab794f08d5e6e9d54dcb792fe58bc513cb70f12 (35 bytes) 56317 17:19:57.031 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 99 └─[SecurityCCCommandEncapsulation] │ nonce id: 121 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[BatteryCCGet] 17:19:57.034 SERIAL « [ACK] (0x06) 17:19:57.041 SERIAL « 0x0104011301e8 (6 bytes) 17:19:57.042 SERIAL » [ACK] (0x06) 17:19:57.043 DRIVER « [RES] [SendData] was sent: true 17:19:57.067 SERIAL « 0x01070013630000038b (9 bytes) 17:19:57.068 SERIAL » [ACK] (0x06) 17:19:57.069 DRIVER « [REQ] [SendData] callback id: 99 transmit status: OK 17:19:57.185 SERIAL « 0x0108000400060298402f (10 bytes) 17:19:57.187 SERIAL » [ACK] (0x06) 17:19:57.188 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:19:57.204 SERIAL » 0x01110013060a9880fe05993e7d9c43a70564d1 (19 bytes) 17:19:57.205 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 100 └─[SecurityCCNonceReport] nonce: 0xfe05993e7d9c43a7 17:19:57.209 SERIAL « [ACK] (0x06) 17:19:57.215 SERIAL « 0x0104011301e8 (6 bytes) 17:19:57.216 SERIAL » [ACK] (0x06) 17:19:57.218 DRIVER « [RES] [SendData] was sent: true 17:19:57.237 SERIAL « 0x01070013640000028d (9 bytes) 17:19:57.238 SERIAL » [ACK] (0x06) 17:19:57.239 DRIVER « [REQ] [SendData] callback id: 100 transmit status: OK 17:19:57.268 SERIAL « 0x0121000400061b9881b192833d1b57290226f4fccf3365be58fe6ecd96ff02c98 (35 bytes) c9492 17:19:57.270 SERIAL » [ACK] (0x06) 17:19:57.273 CNTRLR [Node 006] [~] [Battery] level: 11 => 11 [Endpoint 2] 17:19:57.274 CNTRLR [Node 006] [~] [Battery] isLow: false => false [Endpoint 2] 17:19:57.276 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BatteryCCReport] level: 11 is low: false 17:19:57.284 SERIAL » 0x010a00130703850201256524 (12 bytes) 17:19:57.284 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 101 └─[AssociationCCGet] group id: 1 17:19:57.285 CNTRLR « [Node 006] received response for battery information: [Endpoint 2] level: 11 17:19:57.286 CNTRLR [Node 006] [~] [Battery] interviewComplete: true => tr [Endpoint 2] [internal] ue 17:19:57.320 SERIAL « [ACK] (0x06) 17:19:57.323 SERIAL « 0x0104011301e8 (6 bytes) 17:19:57.324 SERIAL » [ACK] (0x06) 17:19:57.325 DRIVER « [RES] [SendData] was sent: true 17:19:57.328 CNTRLR [Node 006] MultilevelSensorCC: doing a partial interview... 17:19:57.328 CNTRLR » [Node 006] querying Air temperature sensor reading... 17:19:57.347 SERIAL « 0x010700136500000688 (9 bytes) 17:19:57.347 SERIAL » [ACK] (0x06) 17:19:57.348 DRIVER « [REQ] [SendData] callback id: 101 transmit status: OK 17:19:57.425 SERIAL « 0x010c000400070685030105000175 (14 bytes) 17:19:57.426 SERIAL » [ACK] (0x06) 17:19:57.428 CNTRLR [Node 007] [~] [Association] maxNodes[1]: 5 => 5 [internal] 17:19:57.429 CNTRLR [Node 007] [~] [Association] nodeIds[1]: 1 => 1 [internal] 17:19:57.429 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 1 max # of nodes: 5 node IDs: 1 reports to follow: 0 17:19:57.433 SERIAL » 0x010a001303037005342566e4 (12 bytes) 17:19:57.434 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 102 └─[ConfigurationCCGet] parameter #: 52 17:19:57.435 CNTRLR « [Node 007] received information for association group #1: maximum # of nodes: 5 currently assigned nodes: 1 17:19:57.435 CNTRLR [Node 007] [~] [Association] hasLifeline: true => true [internal] 17:19:57.436 CNTRLR [Node 007] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:19:57.437 CNTRLR [Node 007] AssociationGroupInfoCC: doing a partial interview... 17:19:57.438 CNTRLR [Node 007] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 17:19:57.438 CNTRLR [Node 007] NotificationCC: doing a partial interview... 17:19:57.439 CNTRLR [Node 007] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 17:19:57.439 CNTRLR [Node 007] Interview stage completed: CommandClasses 17:19:57.439 CNTRLR [Node 007] Interview stage completed: OverwriteConfig 17:19:57.439 CNTRLR » [Node 007] requesting node neighbors... 17:19:57.443 SERIAL « [ACK] (0x06) 17:19:57.444 SERIAL « 0x0104011301e8 (6 bytes) 17:19:57.444 SERIAL » [ACK] (0x06) 17:19:57.445 DRIVER « [RES] [SendData] was sent: true 17:19:57.516 SERIAL « 0x010700136600000885 (9 bytes) 17:19:57.516 SERIAL » [ACK] (0x06) 17:19:57.517 DRIVER « [REQ] [SendData] callback id: 102 transmit status: OK 17:19:57.526 SERIAL « 0x010b00040003057006340106b3 (13 bytes) 17:19:57.532 CNTRLR [Node 003] [~] [Configuration] 52: 6 => 6 17:19:57.533 SERIAL » [ACK] (0x06) 17:19:57.534 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 52 value size: 1 value: 6 17:19:57.538 SERIAL » 0x01070080070000007f (9 bytes) 17:19:57.538 DRIVER » [Node 007] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:19:57.539 CNTRLR « [Node 003] parameter #52 has value: 6 17:19:57.539 CNTRLR » [Node 003] querying parameter #60 value... 17:19:57.542 SERIAL « [ACK] (0x06) 17:19:57.544 SERIAL « 0x01200180256da46b0300000000000000000000000000000000000000000000000 (34 bytes) 0da 17:19:57.545 SERIAL » [ACK] (0x06) 17:19:57.546 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 9, 11, 12, 14, 15, 19, 22, 24, 25, 26, 28, 30, 31, 33, 34 17:19:57.554 SERIAL » 0x010900130602984025677b (11 bytes) 17:19:57.555 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 103 └─[SecurityCCNonceGet] 17:19:57.556 CNTRLR « [Node 007] node neighbors received: 1, 3, 6, 9, 11, 12, 14, 15, 19, 22, 24, 25, 26, 28, 30, 31, 33, 34 17:19:57.556 CNTRLR [Node 007] Interview stage completed: Neighbors 17:19:57.591 SERIAL « [ACK] (0x06) 17:19:57.595 SERIAL « 0x0104011301e8 (6 bytes) 17:19:57.596 SERIAL » [ACK] (0x06) 17:19:57.597 DRIVER « [RES] [SendData] was sent: true 17:19:57.599 CNTRLR [Node 007] Interview completed 17:19:57.599 CNTRLR [Node 007] The node is ready to be used 17:19:57.602 SERIAL « 0x01070013670000038f (9 bytes) 17:19:57.603 SERIAL » [ACK] (0x06) 17:19:57.605 DRIVER « [REQ] [SendData] callback id: 103 transmit status: OK 17:19:57.607 SERIAL « 0x0110000400060a98801ab99cc18ccad09601 (18 bytes) 17:19:57.608 SERIAL » [ACK] (0x06) 17:19:57.609 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x1ab99cc18ccad096 17:19:57.615 SERIAL » 0x011f0013061898819ea120b3e4258e23b8859928621adf80e1f35423517c25689 (33 bytes) a 17:19:57.616 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 104 └─[SecurityCCCommandEncapsulation] │ nonce id: 26 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 17:19:57.619 SERIAL « [ACK] (0x06) 17:19:57.626 SERIAL « 0x0104011301e8 (6 bytes) 17:19:57.626 SERIAL » [ACK] (0x06) 17:19:57.627 DRIVER « [RES] [SendData] was sent: true 17:19:57.886 SERIAL « 0x010700136800000380 (9 bytes) 17:19:57.886 SERIAL » [ACK] (0x06) 17:19:57.912 DRIVER « [REQ] [SendData] callback id: 104 transmit status: OK 17:19:57.918 SERIAL « 0x0108000400060298402f (10 bytes) 17:19:57.919 SERIAL » [ACK] (0x06) 17:19:57.920 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:19:57.943 SERIAL » 0x01110013060a98807f2d7679310bbb2705697e (19 bytes) 17:19:57.943 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 105 └─[SecurityCCNonceReport] nonce: 0x7f2d7679310bbb27 17:19:57.951 SERIAL « [ACK] (0x06) 17:19:57.953 SERIAL « 0x0104011301e8 (6 bytes) 17:19:57.953 SERIAL » [ACK] (0x06) 17:19:57.954 DRIVER « [RES] [SendData] was sent: true 17:19:57.973 SERIAL « 0x010700136900000381 (9 bytes) 17:19:57.974 SERIAL » [ACK] (0x06) 17:19:57.975 DRIVER « [REQ] [SendData] callback id: 105 transmit status: OK 17:19:58.004 SERIAL « 0x0120000400061a9881f353733d20e4923672dfccc79f32a37f33ff9e10d4f4d5c (34 bytes) 6f6 17:19:58.005 SERIAL » [ACK] (0x06) 17:19:58.006 CNTRLR [Node 006] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 17:19:58.007 CNTRLR [Node 006] [~] [Multilevel Sensor] Air temperature: 22.7 => 18.7 [Endpoint 0] 17:19:58.007 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.7 17:19:58.011 SERIAL » 0x010a0013030370053c256ae0 (12 bytes) 17:19:58.011 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 106 └─[ConfigurationCCGet] parameter #: 60 17:19:58.012 CNTRLR « [Node 006] received current Air temperature sensor reading: 18.7 °C 17:19:58.013 CNTRLR [Node 006] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 17:19:58.013 CNTRLR [Node 006] ThermostatModeCC: doing a partial interview... 17:19:58.013 CNTRLR » [Node 006] querying current thermostat mode... 17:19:58.017 SERIAL « [ACK] (0x06) 17:19:58.019 SERIAL « 0x0104011301e8 (6 bytes) 17:19:58.020 SERIAL » [ACK] (0x06) 17:19:58.021 DRIVER « [RES] [SendData] was sent: true 17:19:58.037 SERIAL « 0x010700136a00000283 (9 bytes) 17:19:58.037 SERIAL » [ACK] (0x06) 17:19:58.038 DRIVER « [REQ] [SendData] callback id: 106 transmit status: OK 17:19:58.048 SERIAL « 0x010c000400030670063c0261a873 (14 bytes) 17:19:58.053 CNTRLR [Node 003] [~] [Configuration] 60: 25000 => 25000 17:19:58.054 SERIAL » [ACK] (0x06) 17:19:58.055 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 2 value: 25000 17:19:58.061 SERIAL » 0x0109001306029840256b77 (11 bytes) 17:19:58.061 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 107 └─[SecurityCCNonceGet] 17:19:58.062 CNTRLR « [Node 003] parameter #60 has value: 25000 17:19:58.062 CNTRLR » [Node 003] querying parameter #61 value... 17:19:58.065 SERIAL « [ACK] (0x06) 17:19:58.070 SERIAL « 0x0104011301e8 (6 bytes) 17:19:58.071 SERIAL » [ACK] (0x06) 17:19:58.072 DRIVER « [RES] [SendData] was sent: true 17:19:58.089 SERIAL « 0x010700136b00000383 (9 bytes) 17:19:58.091 SERIAL » [ACK] (0x06) 17:19:58.091 DRIVER « [REQ] [SendData] callback id: 107 transmit status: OK 17:19:58.112 SERIAL « 0x0110000400060a9880f7380db9c5b5538c2b (18 bytes) 17:19:58.113 SERIAL » [ACK] (0x06) 17:19:58.114 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xf7380db9c5b5538c 17:19:58.118 SERIAL » 0x011d00130616988176077e65bc04ac6d31aff0f71fa9b696c887603e256cbc (31 bytes) 17:19:58.120 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 108 └─[SecurityCCCommandEncapsulation] │ nonce id: 247 └─[ThermostatModeCCGet] 17:19:58.123 SERIAL « [ACK] (0x06) 17:19:58.130 SERIAL « 0x0104011301e8 (6 bytes) 17:19:58.131 SERIAL » [ACK] (0x06) 17:19:58.131 DRIVER « [RES] [SendData] was sent: true 17:19:58.155 SERIAL « 0x010700136c00000384 (9 bytes) 17:19:58.155 SERIAL » [ACK] (0x06) 17:19:58.156 DRIVER « [REQ] [SendData] callback id: 108 transmit status: OK 17:19:58.242 SERIAL « 0x0108000400060298402f (10 bytes) 17:19:58.243 SERIAL » [ACK] (0x06) 17:19:58.244 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:19:58.250 SERIAL » 0x01110013060a9880f2c89648a46fdc88056dfa (19 bytes) 17:19:58.250 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 109 └─[SecurityCCNonceReport] nonce: 0xf2c89648a46fdc88 17:19:58.252 SERIAL « [ACK] (0x06) 17:19:58.258 SERIAL « 0x0104011301e8 (6 bytes) 17:19:58.259 SERIAL » [ACK] (0x06) 17:19:58.260 DRIVER « [RES] [SendData] was sent: true 17:19:58.281 SERIAL « 0x010700136d00000385 (9 bytes) 17:19:58.281 SERIAL » [ACK] (0x06) 17:19:58.282 DRIVER « [REQ] [SendData] callback id: 109 transmit status: OK 17:19:58.309 SERIAL « 0x011d000400061798811eb933ede49d948d58d6e1f5f2d1b273b8f75a87465b (31 bytes) 17:19:58.310 SERIAL » [ACK] (0x06) 17:19:58.312 CNTRLR [Node 006] [~] [Thermostat Mode] mode: 0 => 0 [Endpoint 0] 17:19:58.312 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[ThermostatModeCCReport] mode: Off 17:19:58.316 SERIAL » 0x010a0013030370053d256ee5 (12 bytes) 17:19:58.316 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 110 └─[ConfigurationCCGet] parameter #: 61 17:19:58.317 CNTRLR « [Node 006] received current thermostat mode: Off 17:19:58.317 CNTRLR [Node 006] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 0] [internal] ue => true 17:19:58.318 CNTRLR [Node 006] ThermostatSetpointCC: doing a partial interview... 17:19:58.318 CNTRLR » [Node 006] querying current value of setpoint Heating... 17:19:58.322 SERIAL « [ACK] (0x06) 17:19:58.325 SERIAL « 0x0104011301e8 (6 bytes) 17:19:58.325 SERIAL » [ACK] (0x06) 17:19:58.326 DRIVER « [RES] [SendData] was sent: true 17:19:58.342 SERIAL « 0x010700136e00000287 (9 bytes) 17:19:58.342 SERIAL » [ACK] (0x06) 17:19:58.343 DRIVER « [REQ] [SendData] callback id: 110 transmit status: OK 17:19:58.352 SERIAL « 0x010b000400030570063d0101bd (13 bytes) 17:19:58.358 CNTRLR [Node 003] [~] [Configuration] 61: 1 => 1 17:19:58.359 SERIAL » [ACK] (0x06) 17:19:58.360 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 61 value size: 1 value: 1 17:19:58.365 SERIAL » 0x0109001306029840256f73 (11 bytes) 17:19:58.366 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 111 └─[SecurityCCNonceGet] 17:19:58.366 CNTRLR « [Node 003] parameter #61 has value: 1 17:19:58.367 CNTRLR » [Node 003] querying parameter #62 value... 17:19:58.373 SERIAL « [ACK] (0x06) 17:19:58.376 SERIAL « 0x0104011301e8 (6 bytes) 17:19:58.376 SERIAL » [ACK] (0x06) 17:19:58.378 DRIVER « [RES] [SendData] was sent: true 17:19:58.394 SERIAL « 0x010700136f00000387 (9 bytes) 17:19:58.395 SERIAL » [ACK] (0x06) 17:19:58.396 DRIVER « [REQ] [SendData] callback id: 111 transmit status: OK 17:19:58.417 SERIAL « 0x0110000400060a9880cb967b44d383e51e36 (18 bytes) 17:19:58.417 SERIAL » [ACK] (0x06) 17:19:58.418 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xcb967b44d383e51e 17:19:58.423 SERIAL » 0x011e0013061798810e527cf6a7f740cdf3ce8a34cb481cd96af4cce2192570c8 (32 bytes) 17:19:58.425 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 112 └─[SecurityCCCommandEncapsulation] │ nonce id: 203 └─[ThermostatSetpointCCGet] setpoint type: Heating 17:19:58.428 SERIAL « [ACK] (0x06) 17:19:58.436 SERIAL « 0x0104011301e8 (6 bytes) 17:19:58.437 SERIAL » [ACK] (0x06) 17:19:58.437 DRIVER « [RES] [SendData] was sent: true 17:19:58.460 SERIAL « 0x010700137000000398 (9 bytes) 17:19:58.460 SERIAL » [ACK] (0x06) 17:19:58.461 DRIVER « [REQ] [SendData] callback id: 112 transmit status: OK 17:19:58.553 SERIAL « 0x0108000400060298402f (10 bytes) 17:19:58.553 SERIAL » [ACK] (0x06) 17:19:58.555 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:19:58.561 SERIAL » 0x01110013060a988006f00f5e3f5ee8680571db (19 bytes) 17:19:58.561 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 113 └─[SecurityCCNonceReport] nonce: 0x06f00f5e3f5ee868 17:19:58.563 SERIAL « [ACK] (0x06) 17:19:58.569 SERIAL « 0x0104011301e8 (6 bytes) 17:19:58.569 SERIAL » [ACK] (0x06) 17:19:58.570 DRIVER « [RES] [SendData] was sent: true 17:19:58.591 SERIAL « 0x010700137100000399 (9 bytes) 17:19:58.592 SERIAL » [ACK] (0x06) 17:19:58.592 DRIVER « [REQ] [SendData] callback id: 113 transmit status: OK 17:19:58.601 CNTRLR » [Node 007] Sending node back to sleep... 17:19:58.621 SERIAL « 0x0120000400061a98818db8631f675678b52e09a4ef89ea5e06d0c19b02711d79b (34 bytes) f1e 17:19:58.622 SERIAL » [ACK] (0x06) 17:19:58.624 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpoint[1]: 25 => 25 [Endpoint 0] 17:19:58.625 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 17:19:58.625 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[ThermostatSetpointCCReport] setpoint type: Heating value: 25 °C 17:19:58.632 SERIAL » 0x010900130702840825723b (11 bytes) 17:19:58.633 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 114 └─[WakeUpCCNoMoreInformation] 17:19:58.633 CNTRLR « [Node 006] received current value of setpoint Heating: 25 °C 17:19:58.634 CNTRLR [Node 006] [~] [Thermostat Setpoint] interviewComplete [Endpoint 0] [internal] : true => true 17:19:58.635 CNTRLR [Node 006] ConfigurationCC: Loading configuration parameters from device confi g 17:19:58.640 CNTRLR [Node 006] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:19:58.641 CNTRLR [Node 006] [Configuration] 1: metadata updated 17:19:58.642 CNTRLR [Node 006] [Configuration] 2: metadata updated 17:19:58.643 CNTRLR [Node 006] [Configuration] 3: metadata updated 17:19:58.645 CNTRLR [Node 006] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:19:58.645 CNTRLR » [Node 006] querying parameter #1 value... 17:19:58.650 SERIAL « [ACK] (0x06) 17:19:58.651 SERIAL « 0x0104011301e8 (6 bytes) 17:19:58.651 SERIAL » [ACK] (0x06) 17:19:58.652 DRIVER « [RES] [SendData] was sent: true 17:19:58.691 SERIAL « 0x01070013720000069f (9 bytes) 17:19:58.692 SERIAL » [ACK] (0x06) 17:19:58.693 DRIVER « [REQ] [SendData] callback id: 114 transmit status: OK 17:19:58.699 SERIAL » 0x010a0013030370053e2573fb (12 bytes) 17:19:58.700 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 115 └─[ConfigurationCCGet] parameter #: 62 17:19:58.702 CNTRLR [Node 007] The node is asleep. 17:19:58.705 SERIAL « [ACK] (0x06) 17:19:58.709 SERIAL « 0x0104011301e8 (6 bytes) 17:19:58.710 SERIAL » [ACK] (0x06) 17:19:58.711 DRIVER « [RES] [SendData] was sent: true 17:19:58.726 SERIAL « 0x01070013730000029a (9 bytes) 17:19:58.727 SERIAL » [ACK] (0x06) 17:19:58.728 DRIVER « [REQ] [SendData] callback id: 115 transmit status: OK 17:19:58.737 SERIAL « 0x010b000400030570063e0108b7 (13 bytes) 17:19:58.745 CNTRLR [Node 003] [~] [Configuration] 62: 8 => 8 17:19:58.746 SERIAL » [ACK] (0x06) 17:19:58.747 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 62 value size: 1 value: 8 17:19:58.767 SERIAL » 0x0109001306029840257468 (11 bytes) 17:19:58.768 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 116 └─[SecurityCCNonceGet] 17:19:58.768 CNTRLR « [Node 003] parameter #62 has value: 8 17:19:58.769 CNTRLR » [Node 003] querying parameter #63 value... 17:19:58.775 SERIAL « [ACK] (0x06) 17:19:58.778 SERIAL « 0x0104011301e8 (6 bytes) 17:19:58.780 SERIAL » [ACK] (0x06) 17:19:58.783 DRIVER « [RES] [SendData] was sent: true 17:19:58.842 SERIAL « 0x01070013740000029d (9 bytes) 17:19:58.843 SERIAL » [ACK] (0x06) 17:19:58.844 DRIVER « [REQ] [SendData] callback id: 116 transmit status: OK 17:19:58.847 SERIAL « 0x0110000400060a9880cab1d603d91b5c22ed (18 bytes) 17:19:58.848 SERIAL » [ACK] (0x06) 17:19:58.849 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xcab1d603d91b5c22 17:19:58.853 SERIAL » 0x011e001306179881c8054779a9aa716e786ae7d9caeb20bdf38cdb19fe257596 (32 bytes) 17:19:58.854 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 117 └─[SecurityCCCommandEncapsulation] │ nonce id: 202 └─[ConfigurationCCGet] parameter #: 1 17:19:58.858 SERIAL « [ACK] (0x06) 17:19:58.864 SERIAL « 0x0104011301e8 (6 bytes) 17:19:58.864 SERIAL » [ACK] (0x06) 17:19:58.865 DRIVER « [RES] [SendData] was sent: true 17:19:58.889 SERIAL « 0x01070013750000039d (9 bytes) 17:19:58.889 SERIAL » [ACK] (0x06) 17:19:58.892 DRIVER « [REQ] [SendData] callback id: 117 transmit status: OK 17:19:58.982 SERIAL « 0x0108000400060298402f (10 bytes) 17:19:58.983 SERIAL » [ACK] (0x06) 17:19:58.984 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:19:58.989 SERIAL » 0x01110013060a9880edf062a421a1e4ae05768b (19 bytes) 17:19:58.990 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 118 └─[SecurityCCNonceReport] nonce: 0xedf062a421a1e4ae 17:19:58.992 SERIAL « [ACK] (0x06) 17:19:58.998 SERIAL « 0x0104011301e8 (6 bytes) 17:19:58.998 SERIAL » [ACK] (0x06) 17:19:58.999 DRIVER « [RES] [SendData] was sent: true 17:19:59.020 SERIAL « 0x01070013760000039e (9 bytes) 17:19:59.020 SERIAL » [ACK] (0x06) 17:19:59.021 DRIVER « [REQ] [SendData] callback id: 118 transmit status: OK 17:19:59.051 SERIAL « 0x0122000400061c9881113bfdf181354ba073d97eb4247403c8cfeda3da208da9a (36 bytes) 571984b 17:19:59.052 SERIAL » [ACK] (0x06) 17:19:59.059 CNTRLR [Node 006] [~] [Configuration] 1: 60 => 60 17:19:59.060 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[ConfigurationCCReport] parameter #: 1 value size: 4 value: 60 17:19:59.065 SERIAL » 0x010a0013030370053f2577fe (12 bytes) 17:19:59.065 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 119 └─[ConfigurationCCGet] parameter #: 63 17:19:59.066 CNTRLR « [Node 006] parameter #1 has value: 60 17:19:59.066 CNTRLR » [Node 006] querying parameter #2 value... 17:19:59.070 SERIAL « [ACK] (0x06) 17:19:59.078 SERIAL « 0x0104011301e8 (6 bytes) 17:19:59.079 SERIAL » [ACK] (0x06) 17:19:59.080 DRIVER « [RES] [SendData] was sent: true 17:19:59.091 SERIAL « 0x01070013770000039f (9 bytes) 17:19:59.091 SERIAL » [ACK] (0x06) 17:19:59.092 DRIVER « [REQ] [SendData] callback id: 119 transmit status: OK 17:19:59.101 SERIAL « 0x010b000400030570063f0101bf (13 bytes) 17:19:59.107 CNTRLR [Node 003] [~] [Configuration] 63: 1 => 1 17:19:59.108 SERIAL » [ACK] (0x06) 17:19:59.109 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 63 value size: 1 value: 1 17:19:59.114 SERIAL » 0x0109001306029840257864 (11 bytes) 17:19:59.114 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 120 └─[SecurityCCNonceGet] 17:19:59.117 CNTRLR « [Node 003] parameter #63 has value: 1 17:19:59.117 CNTRLR » [Node 003] querying parameter #70 value... 17:19:59.121 SERIAL « [ACK] (0x06) 17:19:59.126 SERIAL « 0x0104011301e8 (6 bytes) 17:19:59.127 SERIAL » [ACK] (0x06) 17:19:59.128 DRIVER « [RES] [SendData] was sent: true 17:19:59.145 SERIAL « 0x010700137800000291 (9 bytes) 17:19:59.145 SERIAL » [ACK] (0x06) 17:19:59.146 DRIVER « [REQ] [SendData] callback id: 120 transmit status: OK 17:19:59.167 SERIAL « 0x0110000400060a9880da3d95f647b92eb41f (18 bytes) 17:19:59.168 SERIAL » [ACK] (0x06) 17:19:59.169 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xda3d95f647b92eb4 17:19:59.173 SERIAL » 0x011e0013061798816c1d25c216a98df1489ad726dada3f0522d72ea23e2579ad (32 bytes) 17:19:59.173 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 121 └─[SecurityCCCommandEncapsulation] │ nonce id: 218 └─[ConfigurationCCGet] parameter #: 2 17:19:59.176 SERIAL « [ACK] (0x06) 17:19:59.183 SERIAL « 0x0104011301e8 (6 bytes) 17:19:59.184 SERIAL » [ACK] (0x06) 17:19:59.185 DRIVER « [RES] [SendData] was sent: true 17:19:59.208 SERIAL « 0x010700137900000391 (9 bytes) 17:19:59.209 SERIAL » [ACK] (0x06) 17:19:59.209 DRIVER « [REQ] [SendData] callback id: 121 transmit status: OK 17:19:59.302 SERIAL « 0x0108000400060298402f (10 bytes) 17:19:59.303 SERIAL » [ACK] (0x06) 17:19:59.304 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:19:59.309 SERIAL » 0x01110013060a9880c86db92814030690057a23 (19 bytes) 17:19:59.310 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 122 └─[SecurityCCNonceReport] nonce: 0xc86db92814030690 17:19:59.312 SERIAL « [ACK] (0x06) 17:19:59.317 SERIAL « 0x0104011301e8 (6 bytes) 17:19:59.318 SERIAL » [ACK] (0x06) 17:19:59.319 DRIVER « [RES] [SendData] was sent: true 17:19:59.340 SERIAL « 0x010700137a00000392 (9 bytes) 17:19:59.341 SERIAL » [ACK] (0x06) 17:19:59.342 DRIVER « [REQ] [SendData] callback id: 122 transmit status: OK 17:19:59.371 SERIAL « 0x0122000400061c988124aecc82405c6680b0785e2d9b450b79f1c8503462d042d (36 bytes) a4e11db 17:19:59.372 SERIAL » [ACK] (0x06) 17:19:59.378 CNTRLR [Node 006] [~] [Configuration] 2: 1 => 1 17:19:59.379 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[ConfigurationCCReport] parameter #: 2 value size: 4 value: 1 17:19:59.383 SERIAL » 0x010a00130303700546257b8b (12 bytes) 17:19:59.383 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 123 └─[ConfigurationCCGet] parameter #: 70 17:19:59.384 CNTRLR « [Node 006] parameter #2 has value: 1 17:19:59.384 CNTRLR » [Node 006] querying parameter #3 value... 17:19:59.391 SERIAL « [ACK] (0x06) 17:19:59.393 SERIAL « 0x0104011301e8 (6 bytes) 17:19:59.393 SERIAL » [ACK] (0x06) 17:19:59.395 DRIVER « [RES] [SendData] was sent: true 17:19:59.409 SERIAL « 0x010700137b00000292 (9 bytes) 17:19:59.410 SERIAL » [ACK] (0x06) 17:19:59.410 DRIVER « [REQ] [SendData] callback id: 123 transmit status: OK 17:19:59.421 SERIAL « 0x010c000400030670064602ffffc0 (14 bytes) 17:19:59.426 CNTRLR [Node 003] [~] [Configuration] 70: 65535 => 65535 17:19:59.427 SERIAL » [ACK] (0x06) 17:19:59.428 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 70 value size: 2 value: 65535 17:19:59.433 SERIAL » 0x0109001306029840257c60 (11 bytes) 17:19:59.434 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 124 └─[SecurityCCNonceGet] 17:19:59.434 CNTRLR « [Node 003] parameter #70 has value: 65535 17:19:59.435 CNTRLR [Node 003] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:19:59.476 SERIAL « [ACK] (0x06) 17:19:59.481 SERIAL « 0x0104011301e8 (6 bytes) 17:19:59.482 SERIAL » [ACK] (0x06) 17:19:59.484 DRIVER « [RES] [SendData] was sent: true 17:19:59.488 CNTRLR [Node 003] MultiChannelAssociationCC: doing a partial interview... 17:19:59.489 CNTRLR » [Node 003] querying multi channel association group #1... 17:19:59.505 SERIAL « 0x010700137c00000394 (9 bytes) 17:19:59.505 SERIAL » [ACK] (0x06) 17:19:59.508 DRIVER « [REQ] [SendData] callback id: 124 transmit status: OK 17:19:59.513 SERIAL « 0x0110000400060a98804d2e292e8c93d8e6ba (18 bytes) 17:19:59.514 SERIAL » [ACK] (0x06) 17:19:59.516 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x4d2e292e8c93d8e6 17:19:59.522 SERIAL » 0x011e0013061798812129a14b675c630b5623a82a4d2a5ea3b9c90ce7b2257d57 (32 bytes) 17:19:59.523 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 125 └─[SecurityCCCommandEncapsulation] │ nonce id: 77 └─[ConfigurationCCGet] parameter #: 3 17:19:59.526 SERIAL « [ACK] (0x06) 17:19:59.533 SERIAL « 0x0104011301e8 (6 bytes) 17:19:59.534 SERIAL » [ACK] (0x06) 17:19:59.536 DRIVER « [RES] [SendData] was sent: true 17:19:59.558 SERIAL « 0x010700137d00000395 (9 bytes) 17:19:59.560 SERIAL » [ACK] (0x06) 17:19:59.565 DRIVER « [REQ] [SendData] callback id: 125 transmit status: OK 17:19:59.652 SERIAL « 0x0108000400060298402f (10 bytes) 17:19:59.653 SERIAL » [ACK] (0x06) 17:19:59.654 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:19:59.661 SERIAL » 0x01110013060a988062f6ecf3d3844995057e92 (19 bytes) 17:19:59.662 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 126 └─[SecurityCCNonceReport] nonce: 0x62f6ecf3d3844995 17:19:59.664 SERIAL « [ACK] (0x06) 17:19:59.669 SERIAL « 0x0104011301e8 (6 bytes) 17:19:59.670 SERIAL » [ACK] (0x06) 17:19:59.671 DRIVER « [RES] [SendData] was sent: true 17:19:59.692 SERIAL « 0x010700137e00000396 (9 bytes) 17:19:59.692 SERIAL » [ACK] (0x06) 17:19:59.693 DRIVER « [REQ] [SendData] callback id: 126 transmit status: OK 17:19:59.723 SERIAL « 0x0122000400061c98810ad6feaa07315f4287e201a3820a7b0b7c6208c1dc8c8f0 (36 bytes) 9483b34 17:19:59.724 SERIAL » [ACK] (0x06) 17:19:59.730 CNTRLR [Node 006] [~] [Configuration] 3: 0 => 0 17:19:59.731 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[ConfigurationCCReport] parameter #: 3 value size: 4 value: 0 17:19:59.740 SERIAL » 0x01080013080100257fb7 (10 bytes) 17:19:59.741 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 127 └─[NoOperationCC] 17:19:59.741 CNTRLR « [Node 006] parameter #3 has value: 0 17:19:59.742 CNTRLR [Node 006] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:19:59.773 SERIAL « [ACK] (0x06) 17:19:59.779 SERIAL « 0x0104011301e8 (6 bytes) 17:19:59.779 SERIAL » [ACK] (0x06) 17:19:59.781 DRIVER « [RES] [SendData] was sent: true 17:19:59.784 CNTRLR [Node 006] ProtectionCC: doing a partial interview... 17:19:59.784 CNTRLR » [Node 006] querying protection status... 17:20:04.709 SERIAL « 0x010c0004000306310504220506e3 (14 bytes) 17:20:04.710 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:20:04.711 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 272.6 => 128.6 [Endpoint 0] 17:20:04.712 SERIAL » [ACK] (0x06) 17:20:04.713 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 128.6 17:20:04.927 SERIAL « 0x010c0004000306310504220929c0 (14 bytes) 17:20:04.928 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:20:04.928 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 128.6 => 234.5 [Endpoint 0] 17:20:04.929 SERIAL » [ACK] (0x06) 17:20:04.930 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 234.5 17:20:07.142 SERIAL « 0x010c000400030631050422048367 (14 bytes) 17:20:07.143 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:20:07.144 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 234.5 => 115.5 [Endpoint 0] 17:20:07.145 SERIAL » [ACK] (0x06) 17:20:07.146 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 115.5 17:20:12.331 SERIAL « 0x010c0004000306310504220951b8 (14 bytes) 17:20:12.332 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:20:12.333 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 115.5 => 238.5 [Endpoint 0] 17:20:12.334 SERIAL » [ACK] (0x06) 17:20:12.335 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 238.5 17:20:12.518 SERIAL « 0x01090004001b032001ff34 (11 bytes) 17:20:12.520 SERIAL » [ACK] (0x06) 17:20:12.521 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:20:12.523 CNTRLR [Node 027] treating BasicCC Set as a report 17:20:12.524 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:20:17.235 SERIAL « 0x010700137f0106d546 (9 bytes) 17:20:17.235 SERIAL » [ACK] (0x06) 17:20:17.236 DRIVER « [REQ] [SendData] callback id: 127 transmit status: NoAck 17:20:17.247 SERIAL » 0x01080013090100258049 (10 bytes) 17:20:17.248 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 128 └─[NoOperationCC] 17:20:17.249 CNTRLR [Node 008] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 17:20:17.250 CNTRLR [Node 008] The node is asleep. 17:20:17.252 CNTRLR [Node 008] The node is ready to be used 17:20:17.253 CNTRLR [Node 008] ping failed: Failed to send the command after 1 attempts (Status No Ack) 17:20:17.256 CNTRLR [Node 008] ManufacturerSpecificCC: doing a partial interview... 17:20:17.257 CNTRLR [Node 008] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:20:17.304 SERIAL « [ACK] (0x06) 17:20:17.306 SERIAL « 0x0104011301e8 (6 bytes) 17:20:17.307 SERIAL » [ACK] (0x06) 17:20:17.311 DRIVER « [RES] [SendData] was sent: true 17:20:17.317 CNTRLR [Node 008] VersionCC: doing a partial interview... 17:20:17.318 CNTRLR [Node 008] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:20:17.318 CNTRLR [Node 008] trying to load device config 17:20:17.320 SERIAL « 0x01070013800000056e (9 bytes) 17:20:17.321 SERIAL » [ACK] (0x06) 17:20:17.322 DRIVER « [REQ] [SendData] callback id: 128 transmit status: OK 17:20:17.329 SERIAL » 0x010800130a010025814b (10 bytes) 17:20:17.330 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 129 └─[NoOperationCC] 17:20:17.331 CNTRLR « [Node 009] ping successful 17:20:17.332 CNTRLR [Node 009] ManufacturerSpecificCC: doing a partial interview... 17:20:17.333 CNTRLR [Node 009] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:20:17.333 CNTRLR [Node 009] VersionCC: doing a partial interview... 17:20:17.334 CNTRLR [Node 009] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:20:17.335 CNTRLR [Node 009] trying to load device config 17:20:17.338 SERIAL « [ACK] (0x06) 17:20:17.350 CNTRLR [Node 008] device config loaded 17:20:17.351 CNTRLR [Node 008] BatteryCC: doing a partial interview... 17:20:17.351 CNTRLR » [Node 008] querying battery status... 17:20:17.369 CNTRLR [Node 009] device config loaded 17:20:17.370 CNTRLR [Node 009] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 17:20:17.371 CNTRLR [Node 009] AssociationCC: doing a partial interview... 17:20:17.372 CNTRLR [Node 009] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:20:17.372 CNTRLR [Node 009] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:20:17.373 CNTRLR [Node 009] BinarySwitchCC: doing a partial interview... [Endpoint 1] 17:20:17.374 CNTRLR » [Node 009] querying Binary Switch state... [Endpoint 1] 17:20:17.377 SERIAL « 0x0104011301e8 (6 bytes) 17:20:17.378 SERIAL » [ACK] (0x06) 17:20:17.379 DRIVER « [RES] [SendData] was sent: true 17:20:25.048 SERIAL « 0x01070013810103036b (9 bytes) 17:20:25.049 SERIAL » [ACK] (0x06) 17:20:25.049 DRIVER « [REQ] [SendData] callback id: 129 transmit status: NoAck 17:20:25.065 SERIAL » 0x010900130602984025829e (11 bytes) 17:20:25.066 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 130 └─[SecurityCCNonceGet] 17:20:25.066 CNTRLR [Node 010] Node 10 did not respond after 1 attempts, it is presumed dead 17:20:25.067 CNTRLR [Node 010] The node is dead. 17:20:25.070 CNTRLR [Node 010] ping failed: Failed to send the command after 1 attempts (Status No Ack) 17:20:25.071 CNTRLR [Node 010] ManufacturerSpecificCC: doing a partial interview... 17:20:25.072 CNTRLR [Node 010] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:20:25.103 SERIAL « [ACK] (0x06) 17:20:25.112 SERIAL « 0x0104011301e8 (6 bytes) 17:20:25.113 SERIAL » [ACK] (0x06) 17:20:25.115 DRIVER « [RES] [SendData] was sent: true 17:20:25.120 CNTRLR [Node 010] VersionCC: doing a partial interview... 17:20:25.121 CNTRLR [Node 010] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:20:25.121 CNTRLR [Node 010] trying to load device config 17:20:25.131 CNTRLR [Node 010] device config loaded 17:20:25.132 CNTRLR [Node 010] AssociationCC: doing a partial interview... 17:20:25.133 CNTRLR [Node 010] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:20:25.134 CNTRLR [Node 010] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:20:25.134 CNTRLR [Node 010] BinarySwitchCC: doing a partial interview... 17:20:25.135 CNTRLR » [Node 010] querying Binary Switch state... 17:20:25.135 CNTRLR » [Node 010] pinging the node... 17:20:26.358 SERIAL « 0x0107001382000080e9 (9 bytes) 17:20:26.359 SERIAL » [ACK] (0x06) 17:20:26.361 DRIVER « [REQ] [SendData] callback id: 130 transmit status: OK 17:20:26.381 SERIAL « 0x0110000400060a98805037b898c6bc937928 (18 bytes) 17:20:26.382 SERIAL » [ACK] (0x06) 17:20:26.383 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x5037b898c6bc9379 17:20:26.404 SERIAL » 0x011d001306169881dd3d9a671cef104b44a9f95057f44acb17c5615c258362 (31 bytes) 17:20:26.405 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 131 └─[SecurityCCCommandEncapsulation] │ nonce id: 80 └─[ProtectionCCGet] 17:20:26.409 SERIAL « [ACK] (0x06) 17:20:26.416 SERIAL « 0x0104011301e8 (6 bytes) 17:20:26.417 SERIAL » [ACK] (0x06) 17:20:26.418 DRIVER « [RES] [SendData] was sent: true 17:20:26.440 SERIAL « 0x01070013830000036b (9 bytes) 17:20:26.441 SERIAL » [ACK] (0x06) 17:20:26.443 DRIVER « [REQ] [SendData] callback id: 131 transmit status: OK 17:20:26.557 SERIAL « 0x0108000400060298402f (10 bytes) 17:20:26.558 SERIAL » [ACK] (0x06) 17:20:26.559 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:20:26.564 SERIAL » 0x01110013060a9880a406304efc2bcdae058400 (19 bytes) 17:20:26.565 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 132 └─[SecurityCCNonceReport] nonce: 0xa406304efc2bcdae 17:20:26.567 SERIAL « [ACK] (0x06) 17:20:26.573 SERIAL « 0x0104011301e8 (6 bytes) 17:20:26.573 SERIAL » [ACK] (0x06) 17:20:26.574 DRIVER « [RES] [SendData] was sent: true 17:20:26.595 SERIAL « 0x01070013840000036c (9 bytes) 17:20:26.595 SERIAL » [ACK] (0x06) 17:20:26.596 DRIVER « [REQ] [SendData] callback id: 132 transmit status: OK 17:20:26.624 SERIAL « 0x011d0004000617988194e82faab4e4ac3cfd146663a43408e5377077c4ab19 (31 bytes) 17:20:26.625 SERIAL » [ACK] (0x06) 17:20:26.628 CNTRLR [Node 006] [~] [Protection] local: 0 => 0 [Endpoint 0] 17:20:26.628 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[ProtectionCCReport] local: Unprotected 17:20:26.633 SERIAL » 0x010800130a010025854f (10 bytes) 17:20:26.633 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 133 └─[NoOperationCC] 17:20:26.634 CNTRLR « [Node 006] received protection status: local: Unprotected 17:20:26.634 CNTRLR [Node 006] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 17:20:26.667 SERIAL « [ACK] (0x06) 17:20:26.670 SERIAL « 0x0104011301e8 (6 bytes) 17:20:26.670 SERIAL » [ACK] (0x06) 17:20:26.671 DRIVER « [RES] [SendData] was sent: true 17:20:26.673 CNTRLR [Node 006] ClockCC: doing a partial interview... 17:20:26.674 CNTRLR » [Node 006] requesting current clock setting... 17:20:30.005 SERIAL « 0x0108000400060298402f (10 bytes) 17:20:30.005 SERIAL » [ACK] (0x06) 17:20:30.006 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:20:30.670 SERIAL « 0x0108000400060298402f (10 bytes) 17:20:30.671 SERIAL » [ACK] (0x06) 17:20:30.672 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:20:31.331 SERIAL « 0x0108000400060298402f (10 bytes) 17:20:31.332 SERIAL » [ACK] (0x06) 17:20:31.332 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:20:31.583 SERIAL « 0x0108000400060298402f (10 bytes) 17:20:31.583 SERIAL » [ACK] (0x06) 17:20:31.584 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:20:34.852 SERIAL « 0x010c000400030631050422042eca (14 bytes) 17:20:34.854 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:20:34.855 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 238.5 => 107 [Endpoint 0] 17:20:34.856 SERIAL » [ACK] (0x06) 17:20:34.859 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 107 17:20:34.993 SERIAL « 0x010700138501034428 (9 bytes) 17:20:34.993 SERIAL » [ACK] (0x06) 17:20:34.995 DRIVER « [REQ] [SendData] callback id: 133 transmit status: NoAck 17:20:35.003 SERIAL » 0x01110013060a98809b6481b7ebdc0ac6058658 (19 bytes) 17:20:35.008 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 134 └─[SecurityCCNonceReport] nonce: 0x9b6481b7ebdc0ac6 17:20:35.009 CNTRLR [Node 010] Node 10 did not respond after 1 attempts, it is presumed dead 17:20:35.011 CNTRLR [Node 010] ping failed: Failed to send the command after 1 attempts (Status No Ack) 17:20:35.011 CNTRLR [Node 010] Interview attempt (1/5) failed, node is dead. 17:20:35.013 SERIAL « [ACK] (0x06) 17:20:35.018 SERIAL « 0x0104011301e8 (6 bytes) 17:20:35.019 SERIAL » [ACK] (0x06) 17:20:35.020 DRIVER « [RES] [SendData] was sent: true 17:20:35.075 SERIAL « 0x01070013860000066b (9 bytes) 17:20:35.076 SERIAL » [ACK] (0x06) 17:20:35.077 DRIVER « [REQ] [SendData] callback id: 134 transmit status: OK 17:20:35.086 SERIAL » 0x010d00130906600d00012502258707 (15 bytes) 17:20:35.087 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 135 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 17:20:35.089 SERIAL « [ACK] (0x06) 17:20:35.095 SERIAL « 0x0104011301e8 (6 bytes) 17:20:35.096 SERIAL » [ACK] (0x06) 17:20:35.097 DRIVER « [RES] [SendData] was sent: true 17:20:35.237 SERIAL « 0x010700138700000e62 (9 bytes) 17:20:35.238 SERIAL » [ACK] (0x06) 17:20:35.240 DRIVER « [REQ] [SendData] callback id: 135 transmit status: OK 17:20:35.294 SERIAL « 0x0124000400061e9881a280de6419a6d40b56147026fd331322448be29b195706f (38 bytes) 95c529492c2 17:20:35.297 SERIAL » [ACK] (0x06) 17:20:35.300 CNTRLR [Node 006] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 17:20:35.301 CNTRLR [Node 006] [~] [Multilevel Sensor] Air temperature: 18.7 => 19.1 [Endpoint 2] 17:20:35.303 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 19.1 17:20:35.376 SERIAL « 0x010d0004000907600d01002503ff4d (15 bytes) 17:20:35.378 CNTRLR [Node 009] [~] [Binary Switch] currentValue: true => true [Endpoint 1] 17:20:35.379 SERIAL » [ACK] (0x06) 17:20:35.382 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: true 17:20:35.389 SERIAL » 0x0109001306029840258894 (11 bytes) 17:20:35.390 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 136 └─[SecurityCCNonceGet] 17:20:35.391 CNTRLR [Node 009] The node is alive. 17:20:35.392 CNTRLR [Node 009] The node is ready to be used 17:20:35.395 CNTRLR « [Node 009] received Binary Switch state: [Endpoint 1] current value: true 17:20:35.396 CNTRLR [Node 009] [~] [Binary Switch] interviewComplete: true [Endpoint 1] [internal] => true 17:20:35.448 SERIAL « [ACK] (0x06) 17:20:35.455 SERIAL « 0x0104011301e8 (6 bytes) 17:20:35.456 SERIAL » [ACK] (0x06) 17:20:35.458 DRIVER « [RES] [SendData] was sent: true 17:20:35.463 CNTRLR [Node 009] BinarySwitchCC: doing a partial interview... [Endpoint 2] 17:20:35.463 CNTRLR » [Node 009] querying Binary Switch state... [Endpoint 2] 17:20:35.517 SERIAL « 0x010700138800000c6f (9 bytes) 17:20:35.518 SERIAL » [ACK] (0x06) 17:20:35.519 DRIVER « [REQ] [SendData] callback id: 136 transmit status: OK 17:20:35.815 SERIAL « 0x0110000400060a9880704067916b167bdbe4 (18 bytes) 17:20:35.816 SERIAL » [ACK] (0x06) 17:20:35.817 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x704067916b167bdb 17:20:35.821 SERIAL » 0x011d001306169881c746674dd2c7683b0da12970fb522b0e0565a41d258919 (31 bytes) 17:20:35.822 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 137 └─[SecurityCCCommandEncapsulation] │ nonce id: 112 └─[ClockCCGet] 17:20:35.824 SERIAL « [ACK] (0x06) 17:20:35.832 SERIAL « 0x0104011301e8 (6 bytes) 17:20:35.832 SERIAL » [ACK] (0x06) 17:20:35.833 DRIVER « [RES] [SendData] was sent: true 17:20:35.906 SERIAL « 0x010700138900000765 (9 bytes) 17:20:35.907 SERIAL » [ACK] (0x06) 17:20:35.907 DRIVER « [REQ] [SendData] callback id: 137 transmit status: OK 17:20:36.852 SERIAL « 0x010c000400030631050422093fd6 (14 bytes) 17:20:36.854 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:20:36.855 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 107 => 236.7 [Endpoint 0] 17:20:36.856 SERIAL » [ACK] (0x06) 17:20:36.858 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 236.7 17:20:37.509 CNTRLR [Node 006] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 17:20:37.852 SERIAL « 0x010c000400030631050422041efa (14 bytes) 17:20:37.853 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:20:37.854 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 236.7 => 105.4 [Endpoint 0] 17:20:37.855 SERIAL » [ACK] (0x06) 17:20:37.856 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 105.4 17:20:38.015 SERIAL » 0x0109001306029840258a96 (11 bytes) 17:20:38.015 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 138 └─[SecurityCCNonceGet] 17:20:38.017 SERIAL « [ACK] (0x06) 17:20:38.023 SERIAL « 0x0104011301e8 (6 bytes) 17:20:38.024 SERIAL » [ACK] (0x06) 17:20:38.024 DRIVER « [RES] [SendData] was sent: true 17:20:38.081 SERIAL « 0x010700138a00000766 (9 bytes) 17:20:38.082 SERIAL » [ACK] (0x06) 17:20:38.082 DRIVER « [REQ] [SendData] callback id: 138 transmit status: OK 17:20:38.163 SERIAL « 0x0110000400060a9880b5871076169d66a3e5 (18 bytes) 17:20:38.163 SERIAL » [ACK] (0x06) 17:20:38.164 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xb5871076169d66a3 17:20:38.168 SERIAL » 0x011d0013061698819327cd6f8d44c5c3538e32b500e31f6ebea5299c2589eb (31 bytes) 17:20:38.168 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 137 └─[SecurityCCCommandEncapsulation] │ nonce id: 181 └─[ClockCCGet] 17:20:38.171 SERIAL « [ACK] (0x06) 17:20:38.178 SERIAL « 0x0104011301e8 (6 bytes) 17:20:38.179 SERIAL » [ACK] (0x06) 17:20:38.179 DRIVER « [RES] [SendData] was sent: true 17:20:38.305 SERIAL « 0x010700138900000d6f (9 bytes) 17:20:38.306 SERIAL » [ACK] (0x06) 17:20:38.307 DRIVER « [REQ] [SendData] callback id: 137 transmit status: OK 17:20:38.407 SERIAL « 0x0108000400060298402f (10 bytes) 17:20:38.408 SERIAL » [ACK] (0x06) 17:20:38.408 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:20:38.416 SERIAL » 0x01110013060a9880db50c2ebc8eccf86058ba8 (19 bytes) 17:20:38.416 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 139 └─[SecurityCCNonceReport] nonce: 0xdb50c2ebc8eccf86 17:20:38.418 SERIAL « [ACK] (0x06) 17:20:38.424 SERIAL « 0x0104011301e8 (6 bytes) 17:20:38.425 SERIAL » [ACK] (0x06) 17:20:38.425 DRIVER « [RES] [SendData] was sent: true 17:20:38.543 SERIAL « 0x010700138b00000c6c (9 bytes) 17:20:38.544 SERIAL » [ACK] (0x06) 17:20:38.545 DRIVER « [REQ] [SendData] callback id: 139 transmit status: OK 17:20:38.640 SERIAL « 0x011e00040006189881b604991921d17587ddeb622d0adbc7d2ef96cc6b7907cf (32 bytes) 17:20:38.666 SERIAL » [ACK] (0x06) 17:20:38.668 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[ClockCCReport] clock setting: Wednesday, 18:13 17:20:38.675 SERIAL » 0x010d00130906600d00022502258c0f (15 bytes) 17:20:38.676 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 140 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[BinarySwitchCCGet] 17:20:38.677 CNTRLR « [Node 006] received current clock setting: Wednesday, 18:13 17:20:38.678 CNTRLR [Node 006] [~] [Clock] interviewComplete: true => true [Endpoint 0] [internal] 17:20:38.738 SERIAL « [ACK] (0x06) 17:20:38.743 SERIAL « 0x0104011301e8 (6 bytes) 17:20:38.744 SERIAL » [ACK] (0x06) 17:20:38.746 DRIVER « [RES] [SendData] was sent: true 17:20:38.748 CNTRLR [Node 006] AssociationCC: doing a partial interview... 17:20:38.749 CNTRLR [Node 006] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:20:38.749 CNTRLR [Node 006] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:20:38.749 CNTRLR [Node 006] MultiChannelAssociationCC: doing a partial interview... 17:20:38.750 CNTRLR » [Node 006] querying multi channel association group #1... 17:20:38.756 SERIAL « 0x010700138c00000760 (9 bytes) 17:20:38.756 SERIAL » [ACK] (0x06) 17:20:38.757 DRIVER « [REQ] [SendData] callback id: 140 transmit status: OK 17:20:38.809 SERIAL « 0x010d0004000907600d0200250300b1 (15 bytes) 17:20:38.810 CNTRLR [Node 009] [~] [Binary Switch] currentValue: false => false [Endpoint 2] 17:20:38.810 SERIAL » [ACK] (0x06) 17:20:38.812 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BinarySwitchCCReport] current value: false 17:20:38.818 SERIAL » 0x010800130b0100258d46 (10 bytes) 17:20:38.818 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 141 └─[NoOperationCC] 17:20:38.819 CNTRLR « [Node 009] received Binary Switch state: [Endpoint 2] current value: false 17:20:38.819 CNTRLR [Node 009] [~] [Binary Switch] interviewComplete: true [Endpoint 2] [internal] => true 17:20:38.820 CNTRLR [Node 009] BinarySwitchCC: doing a partial interview... 17:20:38.820 CNTRLR » [Node 009] querying Binary Switch state... 17:20:38.826 SERIAL « [ACK] (0x06) 17:20:38.827 SERIAL « 0x0104011301e8 (6 bytes) 17:20:38.828 SERIAL » [ACK] (0x06) 17:20:38.830 DRIVER « [RES] [SendData] was sent: true 17:20:40.269 SERIAL « 0x010c00040003063105042204c521 (14 bytes) 17:20:40.270 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:20:40.270 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 105.4 => 122.1 [Endpoint 0] 17:20:40.271 SERIAL » [ACK] (0x06) 17:20:40.272 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 122.1 17:20:43.709 SERIAL « 0x01090004001b03300300d9 (11 bytes) 17:20:43.711 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:20:43.712 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:20:43.713 SERIAL » [ACK] (0x06) 17:20:43.715 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:20:46.660 SERIAL « 0x01090004001b03200100cb (11 bytes) 17:20:46.661 SERIAL » [ACK] (0x06) 17:20:46.676 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:20:46.679 CNTRLR [Node 027] treating BasicCC Set as a report 17:20:46.681 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:20:48.750 SERIAL « 0x010700138d0103e185 (9 bytes) 17:20:48.751 SERIAL » [ACK] (0x06) 17:20:48.751 DRIVER « [REQ] [SendData] callback id: 141 transmit status: NoAck 17:20:48.756 SERIAL » 0x010800130c0100258e42 (10 bytes) 17:20:48.757 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 142 └─[NoOperationCC] 17:20:48.757 CNTRLR [Node 011] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 17:20:48.757 CNTRLR [Node 011] The node is asleep. 17:20:48.759 CNTRLR [Node 011] The node is ready to be used 17:20:48.760 CNTRLR [Node 011] ping failed: Failed to send the command after 1 attempts (Status No Ack) 17:20:48.761 CNTRLR [Node 011] ManufacturerSpecificCC: doing a partial interview... 17:20:48.762 CNTRLR [Node 011] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:20:48.799 SERIAL « [ACK] (0x06) 17:20:48.808 SERIAL « 0x0104011301e8 (6 bytes) 17:20:48.809 SERIAL » [ACK] (0x06) 17:20:48.812 DRIVER « [RES] [SendData] was sent: true 17:20:48.818 CNTRLR [Node 011] VersionCC: doing a partial interview... 17:20:48.818 CNTRLR [Node 011] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:20:48.819 CNTRLR [Node 011] trying to load device config 17:20:48.821 SERIAL « 0x010700138e00000267 (9 bytes) 17:20:48.822 SERIAL » [ACK] (0x06) 17:20:48.823 DRIVER « [REQ] [SendData] callback id: 142 transmit status: OK 17:20:48.832 SERIAL » 0x010800130d0100258f42 (10 bytes) 17:20:48.832 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 143 └─[NoOperationCC] 17:20:48.834 CNTRLR « [Node 012] ping successful 17:20:48.836 CNTRLR [Node 012] ManufacturerSpecificCC: doing a partial interview... 17:20:48.837 CNTRLR [Node 012] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:20:48.838 CNTRLR [Node 012] VersionCC: doing a partial interview... 17:20:48.838 CNTRLR [Node 012] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:20:48.839 CNTRLR [Node 012] trying to load device config 17:20:48.844 SERIAL « [ACK] (0x06) 17:20:48.846 SERIAL « 0x0104011301e8 (6 bytes) 17:20:48.847 SERIAL » [ACK] (0x06) 17:20:48.850 CNTRLR [Node 011] device config loaded 17:20:48.850 CNTRLR [Node 011] BatteryCC: doing a partial interview... 17:20:48.851 CNTRLR » [Node 011] querying battery status... 17:20:48.861 DRIVER « [RES] [SendData] was sent: true 17:20:48.883 CNTRLR [Node 012] device config loaded 17:20:48.884 CNTRLR [Node 012] AssociationCC: doing a partial interview... 17:20:48.885 CNTRLR » [Node 012] querying association group #1... 17:20:48.889 SERIAL « 0x010700138f00000561 (9 bytes) 17:20:48.889 SERIAL » [ACK] (0x06) 17:20:48.891 DRIVER « [REQ] [SendData] callback id: 143 transmit status: OK 17:20:48.900 SERIAL » 0x010800130e010025905e (10 bytes) 17:20:48.900 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 144 └─[NoOperationCC] 17:20:48.901 CNTRLR « [Node 013] ping successful 17:20:48.902 CNTRLR [Node 013] ManufacturerSpecificCC: doing a partial interview... 17:20:48.902 CNTRLR [Node 013] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:20:48.903 CNTRLR [Node 013] VersionCC: doing a partial interview... 17:20:48.903 CNTRLR [Node 013] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:20:48.903 CNTRLR [Node 013] trying to load device config 17:20:49.063 SERIAL « [ACK] (0x06) 17:20:49.064 SERIAL « 0x0104011301e8 (6 bytes) 17:20:49.064 SERIAL » [ACK] (0x06) 17:20:49.066 DRIVER « [RES] [SendData] was sent: true 17:20:49.104 CNTRLR [Node 013] device config loaded 17:20:49.105 CNTRLR [Node 013] AssociationCC: doing a partial interview... 17:20:49.105 CNTRLR [Node 013] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:20:49.105 CNTRLR [Node 013] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:20:49.106 CNTRLR [Node 013] BinarySwitchCC: doing a partial interview... 17:20:49.106 CNTRLR » [Node 013] querying Binary Switch state... 17:20:49.110 SERIAL « 0x010700139000000279 (9 bytes) 17:20:49.111 SERIAL » [ACK] (0x06) 17:20:49.112 DRIVER « [REQ] [SendData] callback id: 144 transmit status: OK 17:20:49.116 SERIAL » 0x010800130f010025915e (10 bytes) 17:20:49.117 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 145 └─[NoOperationCC] 17:20:49.117 CNTRLR « [Node 014] ping successful 17:20:49.119 CNTRLR [Node 014] ManufacturerSpecificCC: doing a partial interview... 17:20:49.119 CNTRLR [Node 014] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:20:49.119 CNTRLR [Node 014] VersionCC: doing a partial interview... 17:20:49.120 CNTRLR [Node 014] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:20:49.120 CNTRLR [Node 014] trying to load device config 17:20:49.123 SERIAL « [ACK] (0x06) 17:20:49.127 SERIAL « 0x0104011301e8 (6 bytes) 17:20:49.127 SERIAL » [ACK] (0x06) 17:20:49.128 DRIVER « [RES] [SendData] was sent: true 17:20:49.136 CNTRLR [Node 014] device config loaded 17:20:49.137 CNTRLR [Node 014] AssociationCC: doing a partial interview... 17:20:49.137 CNTRLR [Node 014] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:20:49.137 CNTRLR [Node 014] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:20:49.138 CNTRLR [Node 014] BinarySwitchCC: doing a partial interview... 17:20:49.138 CNTRLR » [Node 014] querying Binary Switch state... 17:20:49.143 SERIAL « 0x010700139100000278 (9 bytes) 17:20:49.144 SERIAL » [ACK] (0x06) 17:20:49.144 DRIVER « [REQ] [SendData] callback id: 145 transmit status: OK 17:20:49.149 SERIAL » 0x01080013100100259242 (10 bytes) 17:20:49.149 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 146 └─[NoOperationCC] 17:20:49.150 CNTRLR « [Node 015] ping successful 17:20:49.151 CNTRLR [Node 015] ManufacturerSpecificCC: doing a partial interview... 17:20:49.152 CNTRLR [Node 015] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:20:49.152 CNTRLR [Node 015] VersionCC: doing a partial interview... 17:20:49.152 CNTRLR [Node 015] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:20:49.153 CNTRLR [Node 015] trying to load device config 17:20:49.156 SERIAL « [ACK] (0x06) 17:20:49.158 SERIAL « 0x0104011301e8 (6 bytes) 17:20:49.159 SERIAL » [ACK] (0x06) 17:20:49.159 DRIVER « [RES] [SendData] was sent: true 17:20:49.171 CNTRLR [Node 015] device config loaded 17:20:49.171 CNTRLR [Node 015] AssociationCC: doing a partial interview... 17:20:49.172 CNTRLR [Node 015] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:20:49.172 CNTRLR [Node 015] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:20:49.172 CNTRLR [Node 015] BinarySwitchCC: doing a partial interview... 17:20:49.172 CNTRLR » [Node 015] querying Binary Switch state... 17:20:49.195 SERIAL « 0x01070013920000047d (9 bytes) 17:20:49.196 SERIAL » [ACK] (0x06) 17:20:49.197 DRIVER « [REQ] [SendData] callback id: 146 transmit status: OK 17:20:49.201 SERIAL » 0x010900130902250225937f (11 bytes) 17:20:49.202 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 147 └─[BinarySwitchCCGet] 17:20:49.202 CNTRLR « [Node 016] ping successful 17:20:49.204 CNTRLR [Node 016] ManufacturerSpecificCC: doing a partial interview... 17:20:49.204 CNTRLR [Node 016] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:20:49.204 CNTRLR [Node 016] VersionCC: doing a partial interview... 17:20:49.205 CNTRLR [Node 016] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:20:49.205 CNTRLR [Node 016] trying to load device config 17:20:49.208 SERIAL « [ACK] (0x06) 17:20:49.212 SERIAL « 0x0104011301e8 (6 bytes) 17:20:49.213 SERIAL » [ACK] (0x06) 17:20:49.214 DRIVER « [RES] [SendData] was sent: true 17:20:49.224 CNTRLR [Node 016] device config loaded 17:20:49.224 CNTRLR [Node 016] AssociationCC: doing a partial interview... 17:20:49.224 CNTRLR » [Node 016] querying association group #1... 17:20:49.255 SERIAL « 0x01070013930000057d (9 bytes) 17:20:49.256 SERIAL » [ACK] (0x06) 17:20:49.256 DRIVER « [REQ] [SendData] callback id: 147 transmit status: OK 17:20:49.308 SERIAL « 0x010900040009032503ff21 (11 bytes) 17:20:49.309 CNTRLR [Node 009] [~] [Binary Switch] currentValue: false => true [Endpoint 0] 17:20:49.309 SERIAL » [ACK] (0x06) 17:20:49.310 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: true 17:20:49.313 SERIAL » 0x010a00130c038502012594de (12 bytes) 17:20:49.314 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 148 └─[AssociationCCGet] group id: 1 17:20:49.314 CNTRLR « [Node 009] received Binary Switch state: current value: true 17:20:49.315 CNTRLR [Node 009] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 17:20:49.345 SERIAL « [ACK] (0x06) 17:20:49.349 SERIAL « 0x0104011301e8 (6 bytes) 17:20:49.350 SERIAL » [ACK] (0x06) 17:20:49.351 DRIVER « [RES] [SendData] was sent: true 17:20:49.353 CNTRLR [Node 009] ConfigurationCC: Loading configuration parameters from device confi g 17:20:49.358 CNTRLR [Node 009] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:20:49.359 CNTRLR [Node 009] [Configuration] 1: metadata updated 17:20:49.360 CNTRLR [Node 009] [Configuration] 3: metadata updated 17:20:49.361 CNTRLR [Node 009] [Configuration] 4: metadata updated 17:20:49.363 CNTRLR [Node 009] [Configuration] 5: metadata updated 17:20:49.364 CNTRLR [Node 009] [Configuration] 6: metadata updated 17:20:49.365 CNTRLR [Node 009] [Configuration] 7: metadata updated 17:20:49.366 CNTRLR [Node 009] [Configuration] 13: metadata updated 17:20:49.368 CNTRLR [Node 009] [Configuration] 14: metadata updated 17:20:49.369 CNTRLR [Node 009] [Configuration] 15: metadata updated 17:20:49.370 CNTRLR [Node 009] [Configuration] 16: metadata updated 17:20:49.371 CNTRLR [Node 009] [Configuration] 30: metadata updated 17:20:49.373 CNTRLR [Node 009] [Configuration] 31: metadata updated 17:20:49.374 CNTRLR [Node 009] [Configuration] 32: metadata updated 17:20:49.375 CNTRLR [Node 009] [Configuration] 33: metadata updated 17:20:49.376 CNTRLR [Node 009] [Configuration] 39: metadata updated 17:20:49.378 CNTRLR [Node 009] [Configuration] 40: metadata updated 17:20:49.379 CNTRLR [Node 009] [Configuration] 41: metadata updated 17:20:49.380 CNTRLR [Node 009] [Configuration] 42: metadata updated 17:20:49.382 CNTRLR [Node 009] [Configuration] 43: metadata updated 17:20:49.383 CNTRLR [Node 009] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:20:49.383 CNTRLR » [Node 009] querying parameter #1 value... 17:20:49.396 SERIAL « 0x010700139400000877 (9 bytes) 17:20:49.396 SERIAL » [ACK] (0x06) 17:20:49.398 DRIVER « [REQ] [SendData] callback id: 148 transmit status: OK 17:20:49.409 SERIAL « 0x010b0004000c0585030110006e (13 bytes) 17:20:49.410 SERIAL » [ACK] (0x06) 17:20:49.412 CNTRLR [Node 012] [~] [Association] maxNodes[1]: 16 => 16 [internal] 17:20:49.412 CNTRLR [Node 012] [~] [Association] nodeIds[1]: => [internal] 17:20:49.413 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 1 max # of nodes: 16 node IDs: reports to follow: 0 17:20:49.419 SERIAL » 0x010900130d02250225957d (11 bytes) 17:20:49.419 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 149 └─[BinarySwitchCCGet] 17:20:49.421 CNTRLR [Node 012] The node is alive. 17:20:49.425 CNTRLR [Node 012] The node is ready to be used 17:20:49.426 CNTRLR « [Node 012] received information for association group #1: maximum # of nodes: 16 currently assigned nodes: 17:20:49.427 CNTRLR » [Node 012] querying association group #2... 17:20:49.435 SERIAL « [ACK] (0x06) 17:20:49.437 SERIAL « 0x0104011301e8 (6 bytes) 17:20:49.437 SERIAL » [ACK] (0x06) 17:20:49.439 DRIVER « [RES] [SendData] was sent: true 17:20:49.480 SERIAL « 0x010700139500000678 (9 bytes) 17:20:49.480 SERIAL » [ACK] (0x06) 17:20:49.481 DRIVER « [REQ] [SendData] callback id: 149 transmit status: OK 17:20:49.531 SERIAL « 0x01090004000d032503ff25 (11 bytes) 17:20:49.532 CNTRLR [Node 013] [~] [Binary Switch] currentValue: "unknown" => true [Endpoint 0] 17:20:49.532 SERIAL » [ACK] (0x06) 17:20:49.533 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: true 17:20:49.537 SERIAL » 0x010900130e02250225967d (11 bytes) 17:20:49.537 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 150 └─[BinarySwitchCCGet] 17:20:49.538 CNTRLR [Node 013] The node is alive. 17:20:49.539 CNTRLR [Node 013] The node is ready to be used 17:20:49.540 CNTRLR « [Node 013] received Binary Switch state: current value: true 17:20:49.540 CNTRLR [Node 013] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 17:20:49.574 SERIAL « [ACK] (0x06) 17:20:49.577 SERIAL « 0x0104011301e8 (6 bytes) 17:20:49.578 SERIAL » [ACK] (0x06) 17:20:49.780 DRIVER « [RES] [SendData] was sent: true 17:20:49.784 CNTRLR [Node 013] MultilevelSwitchCC: doing a partial interview... 17:20:49.785 CNTRLR » [Node 013] requesting current switch state... 17:20:49.798 SERIAL « 0x010700139600000875 (9 bytes) 17:20:49.798 SERIAL » [ACK] (0x06) 17:20:49.801 DRIVER « [REQ] [SendData] callback id: 150 transmit status: OK 17:20:49.808 SERIAL « 0x01090004000e032503ff26 (11 bytes) 17:20:49.810 CNTRLR [Node 014] [~] [Binary Switch] currentValue: "unknown" => true [Endpoint 0] 17:20:49.810 SERIAL » [ACK] (0x06) 17:20:49.812 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: true 17:20:49.819 SERIAL » 0x010900130f02250225977d (11 bytes) 17:20:49.819 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 151 └─[BinarySwitchCCGet] 17:20:49.820 CNTRLR [Node 014] The node is alive. 17:20:49.821 CNTRLR [Node 014] The node is ready to be used 17:20:49.822 CNTRLR « [Node 014] received Binary Switch state: current value: true 17:20:49.823 CNTRLR [Node 014] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 17:20:49.823 CNTRLR [Node 014] MultilevelSwitchCC: doing a partial interview... 17:20:49.823 CNTRLR » [Node 014] requesting current switch state... 17:20:50.060 SERIAL « [ACK] (0x06) 17:20:50.061 SERIAL « 0x0104011301e8 (6 bytes) 17:20:50.061 SERIAL » [ACK] (0x06) 17:20:50.067 DRIVER « [RES] [SendData] was sent: true 17:20:50.077 SERIAL « 0x01070013970000027e (9 bytes) 17:20:50.077 SERIAL » [ACK] (0x06) 17:20:50.079 DRIVER « [REQ] [SendData] callback id: 151 transmit status: OK 17:20:50.083 SERIAL « 0x01090004000f032503ff27 (11 bytes) 17:20:50.084 CNTRLR [Node 015] [~] [Binary Switch] currentValue: true => true [Endpoint 0] 17:20:50.085 SERIAL » [ACK] (0x06) 17:20:50.087 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: true 17:20:50.091 SERIAL » 0x010a001310038502012598ce (12 bytes) 17:20:50.091 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 152 └─[AssociationCCGet] group id: 1 17:20:50.092 CNTRLR [Node 015] The node is alive. 17:20:50.094 CNTRLR [Node 015] The node is ready to be used 17:20:50.096 CNTRLR « [Node 015] received Binary Switch state: current value: true 17:20:50.096 CNTRLR [Node 015] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 17:20:50.097 CNTRLR [Node 015] MultilevelSensorCC: doing a partial interview... 17:20:50.097 CNTRLR » [Node 015] querying current sensor reading... 17:20:50.105 SERIAL « [ACK] (0x06) 17:20:50.106 SERIAL « 0x0104011301e8 (6 bytes) 17:20:50.107 SERIAL » [ACK] (0x06) 17:20:50.319 DRIVER « [RES] [SendData] was sent: true 17:20:50.373 SERIAL « 0x010700139800000576 (9 bytes) 17:20:50.375 SERIAL » [ACK] (0x06) 17:20:50.381 DRIVER « [REQ] [SendData] callback id: 152 transmit status: OK 17:20:50.389 SERIAL « 0x010b0004001005850301100072 (13 bytes) 17:20:50.390 SERIAL » [ACK] (0x06) 17:20:50.394 CNTRLR [Node 016] [~] [Association] maxNodes[1]: 16 => 16 [internal] 17:20:50.394 CNTRLR [Node 016] [~] [Association] nodeIds[1]: => [internal] 17:20:50.395 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 1 max # of nodes: 16 node IDs: reports to follow: 0 17:20:50.400 SERIAL » 0x010a00130903700501259924 (12 bytes) 17:20:50.401 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 153 └─[ConfigurationCCGet] parameter #: 1 17:20:50.401 CNTRLR [Node 016] The node is alive. 17:20:50.402 CNTRLR [Node 016] The node is ready to be used 17:20:50.404 CNTRLR « [Node 016] received information for association group #1: maximum # of nodes: 16 currently assigned nodes: 17:20:50.404 CNTRLR » [Node 016] querying association group #2... 17:20:50.565 SERIAL « [ACK] (0x06) 17:20:50.566 SERIAL « 0x0104011301e8 (6 bytes) 17:20:50.567 SERIAL » [ACK] (0x06) 17:20:50.568 DRIVER « [RES] [SendData] was sent: true 17:20:50.570 SERIAL « 0x010700139900000577 (9 bytes) 17:20:50.571 SERIAL » [ACK] (0x06) 17:20:50.572 DRIVER « [REQ] [SendData] callback id: 153 transmit status: OK 17:20:50.576 SERIAL « 0x010b000400090570060101ff75 (13 bytes) 17:20:50.582 CNTRLR [Node 009] [~] [Configuration] 1: 255 => 255 17:20:50.583 SERIAL » [ACK] (0x06) 17:20:50.584 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 255 17:20:50.594 SERIAL » 0x010a00130c03850202259ad3 (12 bytes) 17:20:50.595 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 154 └─[AssociationCCGet] group id: 2 17:20:50.596 CNTRLR « [Node 009] parameter #1 has value: 255 17:20:50.596 CNTRLR » [Node 009] querying parameter #3 value... 17:20:50.603 SERIAL « [ACK] (0x06) 17:20:50.616 SERIAL « 0x0104011301e8 (6 bytes) 17:20:50.616 SERIAL » [ACK] (0x06) 17:20:50.623 DRIVER « [RES] [SendData] was sent: true 17:20:50.846 SERIAL « 0x010700139a00000372 (9 bytes) 17:20:50.846 SERIAL » [ACK] (0x06) 17:20:50.847 DRIVER « [REQ] [SendData] callback id: 154 transmit status: OK 17:20:50.853 SERIAL « 0x010b0004000c0585030210006d (13 bytes) 17:20:50.855 SERIAL » [ACK] (0x06) 17:20:50.857 CNTRLR [Node 012] [~] [Association] maxNodes[2]: 16 => 16 [internal] 17:20:50.858 CNTRLR [Node 012] [~] [Association] nodeIds[2]: => [internal] 17:20:50.858 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 2 max # of nodes: 16 node IDs: reports to follow: 0 17:20:50.864 SERIAL » 0x010900130d022602259b70 (11 bytes) 17:20:50.864 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 155 └─[MultilevelSwitchCCGet] 17:20:50.865 CNTRLR « [Node 012] received information for association group #2: maximum # of nodes: 16 currently assigned nodes: 17:20:50.865 CNTRLR » [Node 012] querying association group #3... 17:20:50.871 SERIAL « 0x010c00040003063105042208a54d (14 bytes) 17:20:50.873 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:20:50.874 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 122.1 => 221.3 [Endpoint 0] 17:20:50.875 SERIAL » [ACK] (0x06) 17:20:50.875 SERIAL « [CAN] (0x18) 17:20:50.876 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 17:20:50.878 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 221.3 17:20:50.976 SERIAL » 0x010900130d022602259b70 (11 bytes) 17:20:50.978 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 155 └─[MultilevelSwitchCCGet] 17:20:50.983 SERIAL « [ACK] (0x06) 17:20:50.989 SERIAL « 0x0104011301e8 (6 bytes) 17:20:50.990 SERIAL » [ACK] (0x06) 17:20:50.993 DRIVER « [RES] [SendData] was sent: true 17:20:51.035 SERIAL « 0x010700139b00000575 (9 bytes) 17:20:51.036 SERIAL » [ACK] (0x06) 17:20:51.038 DRIVER « [REQ] [SendData] callback id: 155 transmit status: OK 17:20:51.085 SERIAL « 0x01090004000d03260363ba (11 bytes) 17:20:51.087 CNTRLR [Node 013] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 0] 17:20:51.088 SERIAL » [ACK] (0x06) 17:20:51.090 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 99 17:20:51.095 SERIAL » 0x010900130e022602259c74 (11 bytes) 17:20:51.096 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 156 └─[MultilevelSwitchCCGet] 17:20:51.097 CNTRLR [Node 013] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 17:20:51.132 SERIAL « [ACK] (0x06) 17:20:51.138 SERIAL « 0x0104011301e8 (6 bytes) 17:20:51.138 SERIAL » [ACK] (0x06) 17:20:51.141 DRIVER « [RES] [SendData] was sent: true 17:20:51.143 CNTRLR [Node 013] MultilevelSensorCC: doing a partial interview... 17:20:51.143 CNTRLR » [Node 013] querying current sensor reading... 17:20:51.176 SERIAL « 0x010700139c00000770 (9 bytes) 17:20:51.177 SERIAL » [ACK] (0x06) 17:20:51.178 DRIVER « [REQ] [SendData] callback id: 156 transmit status: OK 17:20:51.188 SERIAL « 0x01090004000e03260363b9 (11 bytes) 17:20:51.190 CNTRLR [Node 014] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 0] 17:20:51.191 SERIAL » [ACK] (0x06) 17:20:51.193 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 99 17:20:51.197 SERIAL » 0x010900130f023104259d65 (11 bytes) 17:20:51.198 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 157 └─[MultilevelSensorCCGet] 17:20:51.199 CNTRLR [Node 014] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 17:20:51.199 CNTRLR [Node 014] MultilevelSensorCC: doing a partial interview... 17:20:51.200 CNTRLR » [Node 014] querying current sensor reading... 17:20:51.207 SERIAL « [ACK] (0x06) 17:20:51.210 SERIAL « 0x0104011301e8 (6 bytes) 17:20:51.210 SERIAL » [ACK] (0x06) 17:20:51.211 DRIVER « [RES] [SendData] was sent: true 17:20:51.223 SERIAL « 0x010700139d00000274 (9 bytes) 17:20:51.224 SERIAL » [ACK] (0x06) 17:20:51.225 DRIVER « [REQ] [SendData] callback id: 157 transmit status: OK 17:20:51.234 SERIAL « 0x010c0004000f06310504220026ca (14 bytes) 17:20:51.235 CNTRLR [Node 015] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:20:51.236 CNTRLR [Node 015] [~] [Multilevel Sensor] Power: 3.9 => 3.8 [Endpoint 0] 17:20:51.236 SERIAL » [ACK] (0x06) 17:20:51.239 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 3.8 17:20:51.243 SERIAL » 0x010a00131003850202259ecb (12 bytes) 17:20:51.243 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 158 └─[AssociationCCGet] group id: 2 17:20:51.244 CNTRLR « [Node 015] received current sensor reading: sensor type: Power value: 3.8 W 17:20:51.245 CNTRLR [Node 015] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 17:20:51.245 CNTRLR [Node 015] MeterCC: doing a partial interview... 17:20:51.246 CNTRLR » [Node 015] querying meter value (type = Electric, scale = kWh)... 17:20:51.253 SERIAL « [ACK] (0x06) 17:20:51.254 SERIAL « 0x0104011301e8 (6 bytes) 17:20:51.255 SERIAL » [ACK] (0x06) 17:20:51.256 DRIVER « [RES] [SendData] was sent: true 17:20:51.291 SERIAL « 0x010700139e00000570 (9 bytes) 17:20:51.293 SERIAL » [ACK] (0x06) 17:20:51.294 DRIVER « [REQ] [SendData] callback id: 158 transmit status: OK 17:20:51.340 SERIAL « 0x010b0004001005850302100071 (13 bytes) 17:20:51.341 SERIAL » [ACK] (0x06) 17:20:51.342 CNTRLR [Node 016] [~] [Association] maxNodes[2]: 16 => 16 [internal] 17:20:51.343 CNTRLR [Node 016] [~] [Association] nodeIds[2]: => [internal] 17:20:51.344 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 2 max # of nodes: 16 node IDs: reports to follow: 0 17:20:51.348 SERIAL » 0x010a00130903700503259f20 (12 bytes) 17:20:51.349 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 159 └─[ConfigurationCCGet] parameter #: 3 17:20:51.349 CNTRLR « [Node 016] received information for association group #2: maximum # of nodes: 16 currently assigned nodes: 17:20:51.350 CNTRLR » [Node 016] querying association group #3... 17:20:51.384 SERIAL « [ACK] (0x06) 17:20:51.388 SERIAL « 0x0104011301e8 (6 bytes) 17:20:51.388 SERIAL » [ACK] (0x06) 17:20:51.391 DRIVER « [RES] [SendData] was sent: true 17:20:51.457 SERIAL « 0x010700139f00000a7e (9 bytes) 17:20:51.458 SERIAL » [ACK] (0x06) 17:20:51.461 DRIVER « [REQ] [SendData] callback id: 159 transmit status: OK 17:20:51.507 SERIAL « 0x010b0004000905700603010088 (13 bytes) 17:20:51.513 CNTRLR [Node 009] [~] [Configuration] 3: 0 => 0 17:20:51.514 SERIAL » [ACK] (0x06) 17:20:51.515 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 17:20:51.518 SERIAL » 0x010a00130c0385020325a0e8 (12 bytes) 17:20:51.519 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 160 └─[AssociationCCGet] group id: 3 17:20:51.519 CNTRLR « [Node 009] parameter #3 has value: 0 17:20:51.519 CNTRLR » [Node 009] querying parameter #4 value... 17:20:51.525 SERIAL « [ACK] (0x06) 17:20:51.531 SERIAL « 0x0104011301e8 (6 bytes) 17:20:51.532 SERIAL » [ACK] (0x06) 17:20:51.536 DRIVER « [RES] [SendData] was sent: true 17:20:51.598 SERIAL « 0x01070013a00000074c (9 bytes) 17:20:51.599 SERIAL » [ACK] (0x06) 17:20:51.600 DRIVER « [REQ] [SendData] callback id: 160 transmit status: OK 17:20:51.607 SERIAL « 0x010c0004000c0685030301000178 (14 bytes) 17:20:51.608 SERIAL » [ACK] (0x06) 17:20:51.611 CNTRLR [Node 012] [~] [Association] maxNodes[3]: 1 => 1 [internal] 17:20:51.612 CNTRLR [Node 012] [~] [Association] nodeIds[3]: 1 => 1 [internal] 17:20:51.612 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 17:20:51.616 SERIAL » 0x010900130d02310425a15b (11 bytes) 17:20:51.617 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 161 └─[MultilevelSensorCCGet] 17:20:51.617 CNTRLR « [Node 012] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 17:20:51.621 CNTRLR [Node 012] [~] [Association] hasLifeline: true => true [internal] 17:20:51.621 CNTRLR [Node 012] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:20:51.651 SERIAL « [ACK] (0x06) 17:20:51.657 SERIAL « 0x0104011301e8 (6 bytes) 17:20:51.657 SERIAL » [ACK] (0x06) 17:20:51.660 DRIVER « [RES] [SendData] was sent: true 17:20:51.665 CNTRLR [Node 012] BinarySwitchCC: doing a partial interview... 17:20:51.665 CNTRLR » [Node 012] querying Binary Switch state... 17:20:51.671 SERIAL « 0x01070013a10000054f (9 bytes) 17:20:51.672 SERIAL » [ACK] (0x06) 17:20:51.674 DRIVER « [REQ] [SendData] callback id: 161 transmit status: OK 17:20:51.725 SERIAL « 0x010c0004000d06310504220000ee (14 bytes) 17:20:51.726 CNTRLR [Node 013] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:20:51.727 CNTRLR [Node 013] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 17:20:51.728 SERIAL » [ACK] (0x06) 17:20:51.735 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:20:51.741 SERIAL » 0x010900130e02310425a25b (11 bytes) 17:20:51.742 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 162 └─[MultilevelSensorCCGet] 17:20:51.742 CNTRLR « [Node 013] received current sensor reading: sensor type: Power value: 0 W 17:20:51.743 CNTRLR [Node 013] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 17:20:51.744 CNTRLR [Node 013] MeterCC: doing a partial interview... 17:20:51.744 CNTRLR » [Node 013] querying meter value (type = Electric, scale = kWh)... 17:20:51.766 SERIAL « [ACK] (0x06) 17:20:51.768 SERIAL « 0x0104011301e8 (6 bytes) 17:20:51.768 SERIAL » [ACK] (0x06) 17:20:51.780 DRIVER « [RES] [SendData] was sent: true 17:20:51.821 SERIAL « 0x01070013a20000074e (9 bytes) 17:20:51.821 SERIAL » [ACK] (0x06) 17:20:51.824 DRIVER « [REQ] [SendData] callback id: 162 transmit status: OK 17:20:51.829 SERIAL « 0x010c0004000e06310504220000ed (14 bytes) 17:20:51.830 CNTRLR [Node 014] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:20:51.831 CNTRLR [Node 014] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 17:20:51.832 SERIAL » [ACK] (0x06) 17:20:51.835 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:20:51.839 SERIAL » 0x010a00130f0332010025a35f (12 bytes) 17:20:51.839 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 163 └─[MeterCCGet] duration: kWh 17:20:51.840 CNTRLR « [Node 014] received current sensor reading: sensor type: Power value: 0 W 17:20:51.840 CNTRLR [Node 014] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 17:20:51.873 SERIAL « [ACK] (0x06) 17:20:51.878 SERIAL « 0x0104011301e8 (6 bytes) 17:20:51.878 SERIAL » [ACK] (0x06) 17:20:51.886 DRIVER « [RES] [SendData] was sent: true 17:20:51.893 CNTRLR [Node 014] MeterCC: doing a partial interview... 17:20:51.893 CNTRLR » [Node 014] querying meter value (type = Electric, scale = kWh)... 17:20:51.898 SERIAL « 0x01070013a30000024a (9 bytes) 17:20:51.899 SERIAL » [ACK] (0x06) 17:20:51.901 DRIVER « [REQ] [SendData] callback id: 163 transmit status: OK 17:20:51.906 SERIAL « 0x01100004000f0a320221440000682f0000fc (18 bytes) 17:20:51.907 CNTRLR [Node 015] [~] [Meter] value[65537]: 266.71 => 266.71 [Endpoint 0] 17:20:51.908 CNTRLR [Node 015] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 17:20:51.909 SERIAL » [ACK] (0x06) 17:20:51.911 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 266.71 time delta: 0 seconds 17:20:51.923 SERIAL » 0x010a0013100385020325a4f0 (12 bytes) 17:20:51.924 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 164 └─[AssociationCCGet] group id: 3 17:20:51.924 CNTRLR » [Node 015] querying meter value (type = Electric, scale = W)... 17:20:51.930 SERIAL « [ACK] (0x06) 17:20:51.935 SERIAL « 0x0104011301e8 (6 bytes) 17:20:51.936 SERIAL » [ACK] (0x06) 17:20:51.939 DRIVER « [RES] [SendData] was sent: true 17:20:51.970 SERIAL « 0x01070013a40000054a (9 bytes) 17:20:51.971 SERIAL » [ACK] (0x06) 17:20:51.973 DRIVER « [REQ] [SendData] callback id: 164 transmit status: OK 17:20:52.019 SERIAL « 0x010c000400100685030301000164 (14 bytes) 17:20:52.021 SERIAL » [ACK] (0x06) 17:20:52.022 CNTRLR [Node 016] [~] [Association] maxNodes[3]: 1 => 1 [internal] 17:20:52.023 CNTRLR [Node 016] [~] [Association] nodeIds[3]: 1 => 1 [internal] 17:20:52.024 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 17:20:52.029 SERIAL » 0x010a0013090370050425a51d (12 bytes) 17:20:52.029 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 165 └─[ConfigurationCCGet] parameter #: 4 17:20:52.030 CNTRLR « [Node 016] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 17:20:52.030 CNTRLR [Node 016] [~] [Association] hasLifeline: true => true [internal] 17:20:52.031 CNTRLR [Node 016] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:20:52.031 CNTRLR [Node 016] BinarySwitchCC: doing a partial interview... 17:20:52.031 CNTRLR » [Node 016] querying Binary Switch state... 17:20:52.035 SERIAL « [ACK] (0x06) 17:20:52.039 SERIAL « 0x0104011301e8 (6 bytes) 17:20:52.039 SERIAL » [ACK] (0x06) 17:20:52.040 DRIVER « [RES] [SendData] was sent: true 17:20:52.135 SERIAL « 0x01070013a500000a44 (9 bytes) 17:20:52.136 SERIAL » [ACK] (0x06) 17:20:52.137 DRIVER « [REQ] [SendData] callback id: 165 transmit status: OK 17:20:52.188 SERIAL « 0x010c000400090670060402000088 (14 bytes) 17:20:52.193 CNTRLR [Node 009] [~] [Configuration] 4: 0 => 0 17:20:52.194 SERIAL » [ACK] (0x06) 17:20:52.195 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 2 value: 0 17:20:52.202 SERIAL » 0x010900130c02250225a64f (11 bytes) 17:20:52.203 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 166 └─[BinarySwitchCCGet] 17:20:52.203 CNTRLR « [Node 009] parameter #4 has value: 0 17:20:52.204 CNTRLR » [Node 009] querying parameter #5 value... 17:20:52.207 SERIAL « [ACK] (0x06) 17:20:52.213 SERIAL « 0x0104011301e8 (6 bytes) 17:20:52.213 SERIAL » [ACK] (0x06) 17:20:52.214 DRIVER « [RES] [SendData] was sent: true 17:20:52.275 SERIAL « 0x01070013a60000074a (9 bytes) 17:20:52.276 SERIAL » [ACK] (0x06) 17:20:52.276 DRIVER « [REQ] [SendData] callback id: 166 transmit status: OK 17:20:52.285 SERIAL « 0x01090004000c032503ff24 (11 bytes) 17:20:52.286 CNTRLR [Node 012] [~] [Binary Switch] currentValue: true => true [Endpoint 0] 17:20:52.290 SERIAL » [ACK] (0x06) 17:20:52.291 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: true 17:20:52.295 SERIAL » 0x010a00130d0332010025a759 (12 bytes) 17:20:52.295 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 167 └─[MeterCCGet] duration: kWh 17:20:52.296 CNTRLR « [Node 012] received Binary Switch state: current value: true 17:20:52.296 CNTRLR [Node 012] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 17:20:52.324 SERIAL « [ACK] (0x06) 17:20:52.328 SERIAL « 0x0104011301e8 (6 bytes) 17:20:52.328 SERIAL » [ACK] (0x06) 17:20:52.331 DRIVER « [RES] [SendData] was sent: true 17:20:52.333 CNTRLR [Node 012] MultilevelSwitchCC: doing a partial interview... 17:20:52.333 CNTRLR » [Node 012] requesting current switch state... 17:20:52.350 SERIAL « 0x01070013a70000064a (9 bytes) 17:20:52.350 SERIAL » [ACK] (0x06) 17:20:52.351 DRIVER « [REQ] [SendData] callback id: 167 transmit status: OK 17:20:52.404 SERIAL « 0x01100004000d0a32022144000000d200006b (18 bytes) 17:20:52.405 CNTRLR [Node 013] [~] [Meter] value[65537]: 2.1 => 2.1 [Endpoint 0] 17:20:52.406 CNTRLR [Node 013] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 17:20:52.406 SERIAL » [ACK] (0x06) 17:20:52.408 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 2.1 time delta: 0 seconds 17:20:52.411 SERIAL » 0x010a00130e0332010025a855 (12 bytes) 17:20:52.412 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 168 └─[MeterCCGet] duration: kWh 17:20:52.412 CNTRLR » [Node 013] querying meter value (type = Electric, scale = W)... 17:20:52.416 SERIAL « [ACK] (0x06) 17:20:52.420 SERIAL « 0x0104011301e8 (6 bytes) 17:20:52.420 SERIAL » [ACK] (0x06) 17:20:52.421 DRIVER « [RES] [SendData] was sent: true 17:20:52.496 SERIAL « 0x01070013a80000084b (9 bytes) 17:20:52.496 SERIAL » [ACK] (0x06) 17:20:52.497 DRIVER « [REQ] [SendData] callback id: 168 transmit status: OK 17:20:52.508 SERIAL « 0x01100004000e0a320221440000013400008f (18 bytes) 17:20:52.509 CNTRLR [Node 014] [~] [Meter] value[65537]: 3.08 => 3.08 [Endpoint 0] 17:20:52.509 CNTRLR [Node 014] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 17:20:52.510 SERIAL » [ACK] (0x06) 17:20:52.511 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 3.08 time delta: 0 seconds 17:20:52.514 SERIAL » 0x010a00130f0332011025a945 (12 bytes) 17:20:52.515 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 169 └─[MeterCCGet] duration: W 17:20:52.515 CNTRLR » [Node 014] querying meter value (type = Electric, scale = W)... 17:20:52.519 SERIAL « [ACK] (0x06) 17:20:52.523 SERIAL « 0x0104011301e8 (6 bytes) 17:20:52.524 SERIAL » [ACK] (0x06) 17:20:52.525 DRIVER « [RES] [SendData] was sent: true 17:20:52.540 SERIAL « 0x01070013a900000341 (9 bytes) 17:20:52.541 SERIAL » [ACK] (0x06) 17:20:52.542 DRIVER « [REQ] [SendData] callback id: 169 transmit status: OK 17:20:52.552 SERIAL « 0x010e0004000f083202213200270000f6 (16 bytes) 17:20:52.553 CNTRLR [Node 015] [~] [Meter] value[66049]: 0 => 3.9 [Endpoint 0] 17:20:52.554 CNTRLR [Node 015] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 17:20:52.554 SERIAL » [ACK] (0x06) 17:20:52.556 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 3.9 time delta: 0 seconds 17:20:52.564 SERIAL » 0x010900131002250225aa5f (11 bytes) 17:20:52.564 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 170 └─[BinarySwitchCCGet] 17:20:52.565 CNTRLR [Node 015] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 17:20:52.605 SERIAL « [ACK] (0x06) 17:20:52.612 SERIAL « 0x0104011301e8 (6 bytes) 17:20:52.613 SERIAL » [ACK] (0x06) 17:20:52.615 DRIVER « [RES] [SendData] was sent: true 17:20:52.617 CNTRLR [Node 015] ConfigurationCC: Loading configuration parameters from device confi g 17:20:52.627 CNTRLR [Node 015] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:20:52.627 CNTRLR [Node 015] [Configuration] 1: metadata updated 17:20:52.628 CNTRLR [Node 015] [Configuration] 16: metadata updated 17:20:52.629 CNTRLR [Node 015] [Configuration] 34: metadata updated 17:20:52.630 CNTRLR [Node 015] [Configuration] 35: metadata updated 17:20:52.631 CNTRLR [Node 015] [Configuration] 39: metadata updated 17:20:52.632 CNTRLR [Node 015] [Configuration] 40: metadata updated 17:20:52.633 CNTRLR [Node 015] [Configuration] 42: metadata updated 17:20:52.634 CNTRLR [Node 015] [Configuration] 43: metadata updated 17:20:52.635 CNTRLR [Node 015] [Configuration] 45: metadata updated 17:20:52.636 CNTRLR [Node 015] [Configuration] 47: metadata updated 17:20:52.637 CNTRLR [Node 015] [Configuration] 49: metadata updated 17:20:52.638 CNTRLR [Node 015] [Configuration] 50: metadata updated 17:20:52.639 CNTRLR [Node 015] [Configuration] 51: metadata updated 17:20:52.640 CNTRLR [Node 015] [Configuration] 52: metadata updated 17:20:52.641 CNTRLR [Node 015] [Configuration] 60: metadata updated 17:20:52.642 CNTRLR [Node 015] [Configuration] 61: metadata updated 17:20:52.644 CNTRLR [Node 015] [Configuration] 62: metadata updated 17:20:52.645 CNTRLR [Node 015] [Configuration] 63: metadata updated 17:20:52.646 CNTRLR [Node 015] [Configuration] 70: metadata updated 17:20:52.646 CNTRLR [Node 015] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:20:52.647 CNTRLR » [Node 015] querying parameter #1 value... 17:20:52.652 SERIAL « 0x01070013aa00000544 (9 bytes) 17:20:52.652 SERIAL » [ACK] (0x06) 17:20:52.654 DRIVER « [REQ] [SendData] callback id: 170 transmit status: OK 17:20:52.664 SERIAL « 0x010900040010032503ff38 (11 bytes) 17:20:52.665 CNTRLR [Node 016] [~] [Binary Switch] currentValue: "unknown" => true [Endpoint 0] 17:20:52.666 SERIAL » [ACK] (0x06) 17:20:52.668 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: true 17:20:52.673 SERIAL » 0x010a0013090370050525ab12 (12 bytes) 17:20:52.674 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 171 └─[ConfigurationCCGet] parameter #: 5 17:20:52.674 CNTRLR « [Node 016] received Binary Switch state: current value: true 17:20:52.675 CNTRLR [Node 016] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 17:20:52.675 CNTRLR [Node 016] MultilevelSwitchCC: doing a partial interview... 17:20:52.676 CNTRLR » [Node 016] requesting current switch state... 17:20:52.684 SERIAL « [ACK] (0x06) 17:20:52.686 SERIAL « 0x0104011301e8 (6 bytes) 17:20:52.686 SERIAL » [ACK] (0x06) 17:20:52.688 DRIVER « [RES] [SendData] was sent: true 17:20:52.776 SERIAL « 0x01070013ab00000a4a (9 bytes) 17:20:52.776 SERIAL » [ACK] (0x06) 17:20:52.777 DRIVER « [REQ] [SendData] callback id: 171 transmit status: OK 17:20:52.853 SERIAL « 0x010c000400090670060502000089 (14 bytes) 17:20:52.859 CNTRLR [Node 009] [~] [Configuration] 5: 0 => 0 17:20:52.860 SERIAL » [ACK] (0x06) 17:20:52.863 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 2 value: 0 17:20:52.866 SERIAL » 0x010900130c02260225ac46 (11 bytes) 17:20:52.867 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 172 └─[MultilevelSwitchCCGet] 17:20:52.867 CNTRLR « [Node 009] parameter #5 has value: 0 17:20:52.867 CNTRLR » [Node 009] querying parameter #6 value... 17:20:52.872 SERIAL « [ACK] (0x06) 17:20:52.878 SERIAL « 0x0104011301e8 (6 bytes) 17:20:52.879 SERIAL » [ACK] (0x06) 17:20:52.880 DRIVER « [RES] [SendData] was sent: true 17:20:52.915 SERIAL « 0x01070013ac00000443 (9 bytes) 17:20:52.916 SERIAL » [ACK] (0x06) 17:20:52.916 DRIVER « [REQ] [SendData] callback id: 172 transmit status: OK 17:20:52.925 SERIAL « 0x01090004000c03260363bb (11 bytes) 17:20:52.927 CNTRLR [Node 012] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 0] 17:20:52.927 SERIAL » [ACK] (0x06) 17:20:52.928 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 99 17:20:52.931 SERIAL » 0x010a00130d0332011025ad43 (12 bytes) 17:20:52.932 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 173 └─[MeterCCGet] duration: W 17:20:52.933 CNTRLR [Node 012] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 17:20:52.933 CNTRLR [Node 012] MultilevelSensorCC: doing a partial interview... 17:20:52.933 CNTRLR » [Node 012] querying current sensor reading... 17:20:52.937 SERIAL « [ACK] (0x06) 17:20:52.940 SERIAL « 0x0104011301e8 (6 bytes) 17:20:52.941 SERIAL » [ACK] (0x06) 17:20:52.941 DRIVER « [RES] [SendData] was sent: true 17:20:52.986 SERIAL « 0x01070013ad00000543 (9 bytes) 17:20:52.987 SERIAL » [ACK] (0x06) 17:20:52.988 DRIVER « [REQ] [SendData] callback id: 173 transmit status: OK 17:20:53.040 SERIAL « 0x010e0004000d083202213200000000d3 (16 bytes) 17:20:53.041 CNTRLR [Node 013] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 17:20:53.042 CNTRLR [Node 013] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 17:20:53.042 SERIAL » [ACK] (0x06) 17:20:53.044 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 17:20:53.047 SERIAL » 0x010a00130e0332011025ae43 (12 bytes) 17:20:53.047 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 174 └─[MeterCCGet] duration: W 17:20:53.048 CNTRLR [Node 013] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 17:20:53.081 SERIAL « [ACK] (0x06) 17:20:53.082 SERIAL « 0x0104011301e8 (6 bytes) 17:20:53.083 SERIAL » [ACK] (0x06) 17:20:53.085 DRIVER « [RES] [SendData] was sent: true 17:20:53.086 CNTRLR [Node 013] ConfigurationCC: Loading configuration parameters from device confi g 17:20:53.093 CNTRLR [Node 013] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:20:53.093 CNTRLR [Node 013] [Configuration] 3: metadata updated 17:20:53.094 CNTRLR [Node 013] [Configuration] 10: metadata updated 17:20:53.095 CNTRLR [Node 013] [Configuration] 12: metadata updated 17:20:53.096 CNTRLR [Node 013] [Configuration] 13: metadata updated 17:20:53.097 CNTRLR [Node 013] [Configuration] 14: metadata updated 17:20:53.098 CNTRLR [Node 013] [Configuration] 17: metadata updated 17:20:53.114 CNTRLR [Node 013] [Configuration] 18: metadata updated 17:20:53.115 CNTRLR [Node 013] [Configuration] 22: metadata updated 17:20:53.120 CNTRLR [Node 013] [Configuration] 29: metadata updated 17:20:53.121 CNTRLR [Node 013] [Configuration] 30: metadata updated 17:20:53.123 CNTRLR [Node 013] [Configuration] 31: metadata updated 17:20:53.124 CNTRLR [Node 013] [Configuration] 32: metadata updated 17:20:53.127 CNTRLR [Node 013] [Configuration] 33: metadata updated 17:20:53.129 CNTRLR [Node 013] [Configuration] 35: metadata updated 17:20:53.140 CNTRLR [Node 013] [Configuration] 40: metadata updated 17:20:53.141 CNTRLR [Node 013] [Configuration] 42: metadata updated 17:20:53.143 CNTRLR [Node 013] [Configuration] 43: metadata updated 17:20:53.144 CNTRLR [Node 013] [Configuration] 44: metadata updated 17:20:53.146 CNTRLR [Node 013] [Configuration] 50: metadata updated 17:20:53.147 CNTRLR [Node 013] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:20:53.147 CNTRLR » [Node 013] querying parameter #3 value... 17:20:53.158 SERIAL « 0x01070013ae00000742 (9 bytes) 17:20:53.158 SERIAL » [ACK] (0x06) 17:20:53.164 DRIVER « [REQ] [SendData] callback id: 174 transmit status: OK 17:20:53.170 SERIAL « 0x010e0004000e083202213200000000d0 (16 bytes) 17:20:53.171 CNTRLR [Node 014] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 17:20:53.171 CNTRLR [Node 014] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 17:20:53.173 SERIAL » [ACK] (0x06) 17:20:53.175 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 17:20:53.182 SERIAL » 0x010a00130f0370050125af14 (12 bytes) 17:20:53.183 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 175 └─[ConfigurationCCGet] parameter #: 1 17:20:53.184 CNTRLR [Node 014] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 17:20:53.185 CNTRLR [Node 014] ConfigurationCC: Loading configuration parameters from device confi g 17:20:53.191 CNTRLR [Node 014] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:20:53.192 CNTRLR [Node 014] [Configuration] 3: metadata updated 17:20:53.193 CNTRLR [Node 014] [Configuration] 10: metadata updated 17:20:53.195 CNTRLR [Node 014] [Configuration] 12: metadata updated 17:20:53.196 CNTRLR [Node 014] [Configuration] 13: metadata updated 17:20:53.198 CNTRLR [Node 014] [Configuration] 14: metadata updated 17:20:53.201 CNTRLR [Node 014] [Configuration] 17: metadata updated 17:20:53.218 CNTRLR [Node 014] [Configuration] 18: metadata updated 17:20:53.220 CNTRLR [Node 014] [Configuration] 22: metadata updated 17:20:53.224 CNTRLR [Node 014] [Configuration] 29: metadata updated 17:20:53.226 CNTRLR [Node 014] [Configuration] 30: metadata updated 17:20:53.227 CNTRLR [Node 014] [Configuration] 31: metadata updated 17:20:53.228 CNTRLR [Node 014] [Configuration] 32: metadata updated 17:20:53.230 CNTRLR [Node 014] [Configuration] 33: metadata updated 17:20:53.231 CNTRLR [Node 014] [Configuration] 35: metadata updated 17:20:53.232 CNTRLR [Node 014] [Configuration] 40: metadata updated 17:20:53.234 CNTRLR [Node 014] [Configuration] 42: metadata updated 17:20:53.235 CNTRLR [Node 014] [Configuration] 43: metadata updated 17:20:53.236 CNTRLR [Node 014] [Configuration] 44: metadata updated 17:20:53.238 CNTRLR [Node 014] [Configuration] 50: metadata updated 17:20:53.239 CNTRLR [Node 014] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:20:53.239 CNTRLR » [Node 014] querying parameter #3 value... 17:20:53.285 SERIAL « [ACK] (0x06) 17:20:53.286 SERIAL « 0x0104011301e8 (6 bytes) 17:20:53.286 SERIAL » [ACK] (0x06) 17:20:53.296 DRIVER « [RES] [SendData] was sent: true 17:20:53.315 SERIAL « 0x01070013af00000246 (9 bytes) 17:20:53.316 SERIAL » [ACK] (0x06) 17:20:53.318 DRIVER « [REQ] [SendData] callback id: 175 transmit status: OK 17:20:53.325 SERIAL « 0x010b0004000f0570060101018d (13 bytes) 17:20:53.331 CNTRLR [Node 015] [~] [Configuration] 1: 1 => 1 17:20:53.332 SERIAL » [ACK] (0x06) 17:20:53.333 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 1 17:20:53.337 SERIAL » 0x010900131002260225b046 (11 bytes) 17:20:53.338 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 176 └─[MultilevelSwitchCCGet] 17:20:53.338 CNTRLR « [Node 015] parameter #1 has value: 1 17:20:53.339 CNTRLR » [Node 015] querying parameter #16 value... 17:20:53.344 SERIAL « [ACK] (0x06) 17:20:53.349 SERIAL « 0x0104011301e8 (6 bytes) 17:20:53.349 SERIAL » [ACK] (0x06) 17:20:53.350 DRIVER « [RES] [SendData] was sent: true 17:20:53.384 SERIAL « 0x01070013b00000045f (9 bytes) 17:20:53.385 SERIAL » [ACK] (0x06) 17:20:53.385 DRIVER « [REQ] [SendData] callback id: 176 transmit status: OK 17:20:53.431 SERIAL « 0x01090004001003260363a7 (11 bytes) 17:20:53.432 CNTRLR [Node 016] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 0] 17:20:53.432 SERIAL » [ACK] (0x06) 17:20:53.433 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 99 17:20:53.437 SERIAL » 0x010a0013090370050625b10b (12 bytes) 17:20:53.437 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 177 └─[ConfigurationCCGet] parameter #: 6 17:20:53.438 CNTRLR [Node 016] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 17:20:53.438 CNTRLR [Node 016] MultilevelSensorCC: doing a partial interview... 17:20:53.438 CNTRLR » [Node 016] querying current sensor reading... 17:20:53.442 SERIAL « [ACK] (0x06) 17:20:53.445 SERIAL « 0x0104011301e8 (6 bytes) 17:20:53.446 SERIAL » [ACK] (0x06) 17:20:53.447 DRIVER « [RES] [SendData] was sent: true 17:20:53.545 SERIAL « 0x01070013b100000a50 (9 bytes) 17:20:53.545 SERIAL » [ACK] (0x06) 17:20:53.546 DRIVER « [REQ] [SendData] callback id: 177 transmit status: OK 17:20:53.619 SERIAL « 0x010b000400090570060601008d (13 bytes) 17:20:53.624 CNTRLR [Node 009] [~] [Configuration] 6: 0 => 0 17:20:53.625 SERIAL » [ACK] (0x06) 17:20:53.626 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 1 value: 0 17:20:53.629 SERIAL » 0x010900130c02310425b249 (11 bytes) 17:20:53.629 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 178 └─[MultilevelSensorCCGet] 17:20:53.630 CNTRLR « [Node 009] parameter #6 has value: 0 17:20:53.630 CNTRLR » [Node 009] querying parameter #7 value... 17:20:53.634 SERIAL « [ACK] (0x06) 17:20:53.639 SERIAL « 0x0104011301e8 (6 bytes) 17:20:53.639 SERIAL » [ACK] (0x06) 17:20:53.640 DRIVER « [RES] [SendData] was sent: true 17:20:53.685 SERIAL « 0x01070013b20000055c (9 bytes) 17:20:53.685 SERIAL » [ACK] (0x06) 17:20:53.686 DRIVER « [REQ] [SendData] callback id: 178 transmit status: OK 17:20:53.696 SERIAL « 0x010c0004000c06310504220000ef (14 bytes) 17:20:53.697 CNTRLR [Node 012] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:20:53.698 CNTRLR [Node 012] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 17:20:53.698 SERIAL » [ACK] (0x06) 17:20:53.699 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:20:53.717 SERIAL » 0x010a00130d0370050325b308 (12 bytes) 17:20:53.717 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 179 └─[ConfigurationCCGet] parameter #: 3 17:20:53.718 CNTRLR « [Node 012] received current sensor reading: sensor type: Power value: 0 W 17:20:53.718 CNTRLR [Node 012] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 17:20:53.719 CNTRLR [Node 012] MeterCC: doing a partial interview... 17:20:53.719 CNTRLR » [Node 012] querying meter value (type = Electric, scale = kWh)... 17:20:53.724 SERIAL « [ACK] (0x06) 17:20:53.726 SERIAL « 0x0104011301e8 (6 bytes) 17:20:53.727 SERIAL » [ACK] (0x06) 17:20:53.728 DRIVER « [RES] [SendData] was sent: true 17:20:53.773 SERIAL « 0x01070013b30000055d (9 bytes) 17:20:53.773 SERIAL » [ACK] (0x06) 17:20:53.774 DRIVER « [REQ] [SendData] callback id: 179 transmit status: OK 17:20:53.824 SERIAL « 0x010b0004000d0570060301008c (13 bytes) 17:20:53.829 CNTRLR [Node 013] [~] [Configuration] 3: 0 => 0 17:20:53.830 SERIAL » [ACK] (0x06) 17:20:53.831 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 17:20:53.834 SERIAL » 0x010a00130e0370050325b40c (12 bytes) 17:20:53.835 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 180 └─[ConfigurationCCGet] parameter #: 3 17:20:53.835 CNTRLR « [Node 013] parameter #3 has value: 0 17:20:53.835 CNTRLR » [Node 013] querying parameter #10 value... 17:20:53.839 SERIAL « [ACK] (0x06) 17:20:53.843 SERIAL « 0x0104011301e8 (6 bytes) 17:20:53.844 SERIAL » [ACK] (0x06) 17:20:53.845 DRIVER « [RES] [SendData] was sent: true 17:20:53.915 SERIAL « 0x01070013b400000857 (9 bytes) 17:20:53.916 SERIAL » [ACK] (0x06) 17:20:53.917 DRIVER « [REQ] [SendData] callback id: 180 transmit status: OK 17:20:53.926 SERIAL « 0x010b0004000e0570060301008f (13 bytes) 17:20:53.932 CNTRLR [Node 014] [~] [Configuration] 3: 0 => 0 17:20:53.934 SERIAL » [ACK] (0x06) 17:20:53.935 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 17:20:53.939 SERIAL » 0x010a00130f0370051025b51f (12 bytes) 17:20:53.940 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 181 └─[ConfigurationCCGet] parameter #: 16 17:20:53.940 CNTRLR « [Node 014] parameter #3 has value: 0 17:20:53.941 CNTRLR » [Node 014] querying parameter #10 value... 17:20:53.944 SERIAL « [ACK] (0x06) 17:20:53.949 SERIAL « 0x0104011301e8 (6 bytes) 17:20:53.950 SERIAL » [ACK] (0x06) 17:20:53.953 DRIVER « [RES] [SendData] was sent: true 17:20:53.965 SERIAL « 0x01070013b50000025c (9 bytes) 17:20:53.966 SERIAL » [ACK] (0x06) 17:20:53.974 DRIVER « [REQ] [SendData] callback id: 181 transmit status: OK 17:20:53.976 SERIAL « 0x010b0004000f0570061001019c (13 bytes) 17:20:53.981 CNTRLR [Node 015] [~] [Configuration] 16: 1 => 1 17:20:53.983 SERIAL » [ACK] (0x06) 17:20:53.983 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 1 17:20:53.987 SERIAL » 0x010900131002310425b651 (11 bytes) 17:20:53.987 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 182 └─[MultilevelSensorCCGet] 17:20:53.988 CNTRLR « [Node 015] parameter #16 has value: 1 17:20:53.988 CNTRLR » [Node 015] querying parameter #34 value... 17:20:53.994 SERIAL « [ACK] (0x06) 17:20:53.996 SERIAL « 0x0104011301e8 (6 bytes) 17:20:53.997 SERIAL » [ACK] (0x06) 17:20:53.997 DRIVER « [RES] [SendData] was sent: true 17:20:54.033 SERIAL « 0x01070013b600000459 (9 bytes) 17:20:54.034 SERIAL » [ACK] (0x06) 17:20:54.034 DRIVER « [REQ] [SendData] callback id: 182 transmit status: OK 17:20:54.083 SERIAL « 0x010c0004001006310504220000f3 (14 bytes) 17:20:54.085 CNTRLR [Node 016] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:20:54.090 CNTRLR [Node 016] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 17:20:54.091 SERIAL » [ACK] (0x06) 17:20:54.092 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:20:54.098 SERIAL » 0x010a0013090370050725b70c (12 bytes) 17:20:54.099 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 183 └─[ConfigurationCCGet] parameter #: 7 17:20:54.100 CNTRLR « [Node 016] received current sensor reading: sensor type: Power value: 0 W 17:20:54.100 CNTRLR [Node 016] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 17:20:54.157 SERIAL « [ACK] (0x06) 17:20:54.158 SERIAL « 0x0104011301e8 (6 bytes) 17:20:54.159 SERIAL » [ACK] (0x06) 17:20:54.162 DRIVER « [RES] [SendData] was sent: true 17:20:54.165 CNTRLR [Node 016] MeterCC: doing a partial interview... 17:20:54.166 CNTRLR » [Node 016] querying meter value (type = Electric, scale = kWh)... 17:20:54.195 SERIAL « 0x01070013b700000955 (9 bytes) 17:20:54.195 SERIAL » [ACK] (0x06) 17:20:54.196 DRIVER « [REQ] [SendData] callback id: 183 transmit status: OK 17:20:54.247 SERIAL « 0x010b000400090570060701008c (13 bytes) 17:20:54.253 CNTRLR [Node 009] [~] [Configuration] 7: 0 => 0 17:20:54.254 SERIAL » [ACK] (0x06) 17:20:54.254 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 7 value size: 1 value: 0 17:20:54.258 SERIAL » 0x010a00130c0332010025b847 (12 bytes) 17:20:54.258 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 184 └─[MeterCCGet] duration: kWh 17:20:54.259 CNTRLR « [Node 009] parameter #7 has value: 0 17:20:54.259 CNTRLR » [Node 009] querying parameter #13 value... 17:20:54.262 SERIAL « [ACK] (0x06) 17:20:54.267 SERIAL « 0x0104011301e8 (6 bytes) 17:20:54.268 SERIAL » [ACK] (0x06) 17:20:54.269 DRIVER « [RES] [SendData] was sent: true 17:20:54.336 SERIAL « 0x01070013b800000754 (9 bytes) 17:20:54.336 SERIAL » [ACK] (0x06) 17:20:54.337 DRIVER « [REQ] [SendData] callback id: 184 transmit status: OK 17:20:54.348 SERIAL « 0x01100004000c0a32022144000000cb000073 (18 bytes) 17:20:54.349 CNTRLR [Node 012] [~] [Meter] value[65537]: 2.03 => 2.03 [Endpoint 0] 17:20:54.349 CNTRLR [Node 012] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 17:20:54.350 SERIAL » [ACK] (0x06) 17:20:54.351 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 2.03 time delta: 0 seconds 17:20:54.354 SERIAL » 0x010a00130d0370050a25b90b (12 bytes) 17:20:54.355 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 185 └─[ConfigurationCCGet] parameter #: 10 17:20:54.355 CNTRLR » [Node 012] querying meter value (type = Electric, scale = W)... 17:20:54.359 SERIAL « [ACK] (0x06) 17:20:54.363 SERIAL « 0x0104011301e8 (6 bytes) 17:20:54.364 SERIAL » [ACK] (0x06) 17:20:54.364 DRIVER « [RES] [SendData] was sent: true 17:20:54.409 SERIAL « 0x01070013b900000557 (9 bytes) 17:20:54.410 SERIAL » [ACK] (0x06) 17:20:54.410 DRIVER « [REQ] [SendData] callback id: 185 transmit status: OK 17:20:54.460 SERIAL « 0x010b0004000d0570060a010184 (13 bytes) 17:20:54.466 CNTRLR [Node 013] [~] [Configuration] 10: 1 => 1 17:20:54.467 SERIAL » [ACK] (0x06) 17:20:54.468 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 1 17:20:54.472 SERIAL » 0x010a00130e0370050a25ba0b (12 bytes) 17:20:54.472 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 186 └─[ConfigurationCCGet] parameter #: 10 17:20:54.473 CNTRLR « [Node 013] parameter #10 has value: 1 17:20:54.474 CNTRLR » [Node 013] querying parameter #12 value... 17:20:54.477 SERIAL « [ACK] (0x06) 17:20:54.481 SERIAL « 0x0104011301e8 (6 bytes) 17:20:54.482 SERIAL » [ACK] (0x06) 17:20:54.482 DRIVER « [RES] [SendData] was sent: true 17:20:54.556 SERIAL « 0x01070013ba00000859 (9 bytes) 17:20:54.557 SERIAL » [ACK] (0x06) 17:20:54.558 DRIVER « [REQ] [SendData] callback id: 186 transmit status: OK 17:20:54.566 SERIAL « 0x010b0004000e0570060a010187 (13 bytes) 17:20:54.572 CNTRLR [Node 014] [~] [Configuration] 10: 1 => 1 17:20:54.573 SERIAL » [ACK] (0x06) 17:20:54.574 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 1 17:20:54.579 SERIAL » 0x010a00130f0370052225bb23 (12 bytes) 17:20:54.580 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 187 └─[ConfigurationCCGet] parameter #: 34 17:20:54.580 CNTRLR « [Node 014] parameter #10 has value: 1 17:20:54.581 CNTRLR » [Node 014] querying parameter #12 value... 17:20:54.584 SERIAL « [ACK] (0x06) 17:20:54.588 SERIAL « 0x0104011301e8 (6 bytes) 17:20:54.589 SERIAL » [ACK] (0x06) 17:20:54.589 DRIVER « [RES] [SendData] was sent: true 17:20:54.605 SERIAL « 0x01070013bb00000252 (9 bytes) 17:20:54.606 SERIAL » [ACK] (0x06) 17:20:54.607 DRIVER « [REQ] [SendData] callback id: 187 transmit status: OK 17:20:54.616 SERIAL « 0x010b0004000f05700622013f90 (13 bytes) 17:20:54.621 CNTRLR [Node 015] [~] [Configuration] 34: 63 => 63 17:20:54.622 SERIAL » [ACK] (0x06) 17:20:54.623 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 34 value size: 1 value: 63 17:20:54.628 SERIAL » 0x010a0013100332010025bc5f (12 bytes) 17:20:54.629 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 188 └─[MeterCCGet] duration: kWh 17:20:54.629 CNTRLR « [Node 015] parameter #34 has value: 63 17:20:54.630 CNTRLR » [Node 015] querying parameter #35 value... 17:20:54.633 SERIAL « [ACK] (0x06) 17:20:54.637 SERIAL « 0x0104011301e8 (6 bytes) 17:20:54.638 SERIAL » [ACK] (0x06) 17:20:54.638 DRIVER « [RES] [SendData] was sent: true 17:20:54.675 SERIAL « 0x01070013bc00000453 (9 bytes) 17:20:54.676 SERIAL » [ACK] (0x06) 17:20:54.677 DRIVER « [REQ] [SendData] callback id: 188 transmit status: OK 17:20:54.727 SERIAL « 0x0110000400100a320221440000014e0000eb (18 bytes) 17:20:54.728 CNTRLR [Node 016] [~] [Meter] value[65537]: 3.34 => 3.34 [Endpoint 0] 17:20:54.728 CNTRLR [Node 016] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 17:20:54.729 SERIAL » [ACK] (0x06) 17:20:54.730 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 3.34 time delta: 0 seconds 17:20:54.733 SERIAL » 0x010a0013090370050d25bd0c (12 bytes) 17:20:54.734 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 189 └─[ConfigurationCCGet] parameter #: 13 17:20:54.734 CNTRLR » [Node 016] querying meter value (type = Electric, scale = W)... 17:20:54.738 SERIAL « [ACK] (0x06) 17:20:54.742 SERIAL « 0x0104011301e8 (6 bytes) 17:20:54.742 SERIAL » [ACK] (0x06) 17:20:54.743 DRIVER « [RES] [SendData] was sent: true 17:20:54.845 SERIAL « 0x01070013bd00000b5d (9 bytes) 17:20:54.845 SERIAL » [ACK] (0x06) 17:20:54.846 DRIVER « [REQ] [SendData] callback id: 189 transmit status: OK 17:20:54.897 SERIAL « 0x010b000400090570060d010086 (13 bytes) 17:20:54.905 CNTRLR [Node 009] [~] [Configuration] 13: 0 => 0 17:20:54.906 SERIAL » [ACK] (0x06) 17:20:54.907 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 0 17:20:54.912 SERIAL » 0x010a00130c0332011025be51 (12 bytes) 17:20:54.912 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 190 └─[MeterCCGet] duration: W 17:20:54.913 CNTRLR « [Node 009] parameter #13 has value: 0 17:20:54.913 CNTRLR » [Node 009] querying parameter #14 value... 17:20:54.917 SERIAL « [ACK] (0x06) 17:20:54.927 SERIAL « 0x0104011301e8 (6 bytes) 17:20:54.931 SERIAL » [ACK] (0x06) 17:20:54.932 DRIVER « [RES] [SendData] was sent: true 17:20:54.985 SERIAL « 0x01070013be00000752 (9 bytes) 17:20:54.986 SERIAL » [ACK] (0x06) 17:20:54.987 DRIVER « [REQ] [SendData] callback id: 190 transmit status: OK 17:20:54.997 SERIAL « 0x010e0004000c083202213200000000d2 (16 bytes) 17:20:54.998 CNTRLR [Node 012] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 17:20:54.999 CNTRLR [Node 012] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 17:20:55.000 SERIAL » [ACK] (0x06) 17:20:55.003 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 17:20:55.008 SERIAL » 0x010a00130d0370050c25bf0b (12 bytes) 17:20:55.015 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 191 └─[ConfigurationCCGet] parameter #: 12 17:20:55.016 CNTRLR [Node 012] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 17:20:55.073 SERIAL « [ACK] (0x06) 17:20:55.075 SERIAL « 0x0104011301e8 (6 bytes) 17:20:55.075 SERIAL » [ACK] (0x06) 17:20:55.081 DRIVER « [RES] [SendData] was sent: true 17:20:55.083 SERIAL « 0x01070013bf00000652 (9 bytes) 17:20:55.084 SERIAL » [ACK] (0x06) 17:20:55.085 CNTRLR [Node 012] ConfigurationCC: Loading configuration parameters from device confi g 17:20:55.095 CNTRLR [Node 012] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:20:55.096 CNTRLR [Node 012] [Configuration] 1: metadata updated 17:20:55.098 CNTRLR [Node 012] [Configuration] 2: metadata updated 17:20:55.101 CNTRLR [Node 012] [Configuration] 3: metadata updated 17:20:55.103 CNTRLR [Node 012] [Configuration] 10: metadata updated 17:20:55.104 CNTRLR [Node 012] [Configuration] 12: metadata updated 17:20:55.105 CNTRLR [Node 012] [Configuration] 13: metadata updated 17:20:55.107 CNTRLR [Node 012] [Configuration] 14: metadata updated 17:20:55.112 CNTRLR [Node 012] [Configuration] 17: metadata updated 17:20:55.114 CNTRLR [Node 012] [Configuration] 18: metadata updated 17:20:55.116 CNTRLR [Node 012] [Configuration] 22: metadata updated 17:20:55.119 CNTRLR [Node 012] [Configuration] 29: metadata updated 17:20:55.121 CNTRLR [Node 012] [Configuration] 30: metadata updated 17:20:55.123 CNTRLR [Node 012] [Configuration] 31: metadata updated 17:20:55.127 CNTRLR [Node 012] [Configuration] 32: metadata updated 17:20:55.129 CNTRLR [Node 012] [Configuration] 33: metadata updated 17:20:55.131 CNTRLR [Node 012] [Configuration] 35: metadata updated 17:20:55.132 CNTRLR [Node 012] [Configuration] 40: metadata updated 17:20:55.134 CNTRLR [Node 012] [Configuration] 42: metadata updated 17:20:55.135 CNTRLR [Node 012] [Configuration] 43: metadata updated 17:20:55.136 CNTRLR [Node 012] [Configuration] 44: metadata updated 17:20:55.138 CNTRLR [Node 012] [Configuration] 50: metadata updated 17:20:55.139 CNTRLR [Node 012] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:20:55.140 CNTRLR » [Node 012] querying parameter #1 value... 17:20:55.143 DRIVER « [REQ] [SendData] callback id: 191 transmit status: OK 17:20:55.147 SERIAL « 0x010c0004000d0670060c02009612 (14 bytes) 17:20:55.155 CNTRLR [Node 013] [~] [Configuration] 12: 150 => 150 17:20:55.156 SERIAL » [ACK] (0x06) 17:20:55.157 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 150 17:20:55.161 SERIAL » 0x010a00130e0370050c25c077 (12 bytes) 17:20:55.161 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 192 └─[ConfigurationCCGet] parameter #: 12 17:20:55.162 CNTRLR « [Node 013] parameter #12 has value: 150 17:20:55.162 CNTRLR » [Node 013] querying parameter #13 value... 17:20:55.166 SERIAL « [ACK] (0x06) 17:20:55.169 SERIAL « 0x0104011301e8 (6 bytes) 17:20:55.170 SERIAL » [ACK] (0x06) 17:20:55.171 DRIVER « [RES] [SendData] was sent: true 17:20:55.216 SERIAL « 0x01070013c00000052e (9 bytes) 17:20:55.217 SERIAL » [ACK] (0x06) 17:20:55.217 DRIVER « [REQ] [SendData] callback id: 192 transmit status: OK 17:20:55.227 SERIAL « 0x010c0004000e0670060c02009611 (14 bytes) 17:20:55.233 CNTRLR [Node 014] [~] [Configuration] 12: 150 => 150 17:20:55.233 SERIAL » [ACK] (0x06) 17:20:55.235 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 150 17:20:55.239 SERIAL » 0x010a00130f0370052325c158 (12 bytes) 17:20:55.240 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 193 └─[ConfigurationCCGet] parameter #: 35 17:20:55.241 CNTRLR « [Node 014] parameter #12 has value: 150 17:20:55.241 CNTRLR » [Node 014] querying parameter #13 value... 17:20:55.244 SERIAL « [ACK] (0x06) 17:20:55.248 SERIAL « 0x0104011301e8 (6 bytes) 17:20:55.249 SERIAL » [ACK] (0x06) 17:20:55.249 DRIVER « [RES] [SendData] was sent: true 17:20:55.265 SERIAL « 0x01070013c100000228 (9 bytes) 17:20:55.266 SERIAL » [ACK] (0x06) 17:20:55.267 DRIVER « [REQ] [SendData] callback id: 193 transmit status: OK 17:20:55.276 SERIAL « 0x010b0004000f057006230100ae (13 bytes) 17:20:55.282 CNTRLR [Node 015] [~] [Configuration] 35: 0 => 0 17:20:55.282 SERIAL » [ACK] (0x06) 17:20:55.283 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 0 17:20:55.287 SERIAL » 0x010a0013100332011025c231 (12 bytes) 17:20:55.288 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 194 └─[MeterCCGet] duration: W 17:20:55.289 CNTRLR « [Node 015] parameter #35 has value: 0 17:20:55.289 CNTRLR » [Node 015] querying parameter #39 value... 17:20:55.292 SERIAL « [ACK] (0x06) 17:20:55.299 SERIAL « 0x0104011301e8 (6 bytes) 17:20:55.300 SERIAL » [ACK] (0x06) 17:20:55.315 DRIVER « [RES] [SendData] was sent: true 17:20:55.335 SERIAL « 0x01070013c20000042d (9 bytes) 17:20:55.336 SERIAL » [ACK] (0x06) 17:20:55.337 DRIVER « [REQ] [SendData] callback id: 194 transmit status: OK 17:20:55.384 SERIAL « 0x010e00040010083202213200000000ce (16 bytes) 17:20:55.386 CNTRLR [Node 016] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 17:20:55.387 CNTRLR [Node 016] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 17:20:55.388 SERIAL » [ACK] (0x06) 17:20:55.390 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 17:20:55.396 SERIAL » 0x010a0013090370050e25c371 (12 bytes) 17:20:55.397 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 195 └─[ConfigurationCCGet] parameter #: 14 17:20:55.398 CNTRLR [Node 016] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 17:20:55.431 SERIAL « [ACK] (0x06) 17:20:55.436 SERIAL « 0x0104011301e8 (6 bytes) 17:20:55.437 SERIAL » [ACK] (0x06) 17:20:55.439 DRIVER « [RES] [SendData] was sent: true 17:20:55.452 CNTRLR [Node 016] ConfigurationCC: Loading configuration parameters from device confi g 17:20:55.458 CNTRLR [Node 016] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:20:55.459 CNTRLR [Node 016] [Configuration] 1: metadata updated 17:20:55.460 CNTRLR [Node 016] [Configuration] 2: metadata updated 17:20:55.461 CNTRLR [Node 016] [Configuration] 3: metadata updated 17:20:55.465 CNTRLR [Node 016] [Configuration] 10: metadata updated 17:20:55.467 CNTRLR [Node 016] [Configuration] 12: metadata updated 17:20:55.468 CNTRLR [Node 016] [Configuration] 13: metadata updated 17:20:55.470 CNTRLR [Node 016] [Configuration] 14: metadata updated 17:20:55.471 CNTRLR [Node 016] [Configuration] 17: metadata updated 17:20:55.473 CNTRLR [Node 016] [Configuration] 18: metadata updated 17:20:55.475 CNTRLR [Node 016] [Configuration] 22: metadata updated 17:20:55.476 CNTRLR [Node 016] [Configuration] 29: metadata updated 17:20:55.477 CNTRLR [Node 016] [Configuration] 30: metadata updated 17:20:55.479 CNTRLR [Node 016] [Configuration] 31: metadata updated 17:20:55.480 CNTRLR [Node 016] [Configuration] 32: metadata updated 17:20:55.481 CNTRLR [Node 016] [Configuration] 33: metadata updated 17:20:55.482 CNTRLR [Node 016] [Configuration] 35: metadata updated 17:20:55.484 CNTRLR [Node 016] [Configuration] 40: metadata updated 17:20:55.486 CNTRLR [Node 016] [Configuration] 42: metadata updated 17:20:55.488 CNTRLR [Node 016] [Configuration] 43: metadata updated 17:20:55.489 CNTRLR [Node 016] [Configuration] 44: metadata updated 17:20:55.491 CNTRLR [Node 016] [Configuration] 50: metadata updated 17:20:55.492 CNTRLR [Node 016] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:20:55.492 CNTRLR » [Node 016] querying parameter #1 value... 17:20:55.503 SERIAL « 0x01070013c300000921 (9 bytes) 17:20:55.503 SERIAL » [ACK] (0x06) 17:20:55.504 DRIVER « [REQ] [SendData] callback id: 195 transmit status: OK 17:20:55.548 SERIAL « 0x010b000400090570060e010184 (13 bytes) 17:20:55.557 CNTRLR [Node 009] [~] [Configuration] 14: 1 => 1 17:20:55.559 SERIAL » [ACK] (0x06) 17:20:55.561 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 1 17:20:55.571 SERIAL » 0x010a00130c0370050125c47c (12 bytes) 17:20:55.572 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 196 └─[ConfigurationCCGet] parameter #: 1 17:20:55.572 CNTRLR « [Node 009] parameter #14 has value: 1 17:20:55.573 CNTRLR » [Node 009] querying parameter #15 value... 17:20:55.595 SERIAL « [ACK] (0x06) 17:20:55.597 SERIAL « 0x0104011301e8 (6 bytes) 17:20:55.597 SERIAL » [ACK] (0x06) 17:20:55.604 DRIVER « [RES] [SendData] was sent: true 17:20:55.636 SERIAL « 0x01070013c400000629 (9 bytes) 17:20:55.636 SERIAL » [ACK] (0x06) 17:20:55.638 DRIVER « [REQ] [SendData] callback id: 196 transmit status: OK 17:20:57.242 CNTRLR [Node 012] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 17:20:57.748 SERIAL » 0x010a00130c0370050125c47c (12 bytes) 17:20:57.749 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 196 └─[ConfigurationCCGet] parameter #: 1 17:20:57.751 SERIAL « [ACK] (0x06) 17:20:57.757 SERIAL « 0x0104011301e8 (6 bytes) 17:20:57.758 SERIAL » [ACK] (0x06) 17:20:57.759 DRIVER « [RES] [SendData] was sent: true 17:20:57.775 SERIAL « 0x01070013c40000022d (9 bytes) 17:20:57.776 SERIAL » [ACK] (0x06) 17:20:57.777 DRIVER « [REQ] [SendData] callback id: 196 transmit status: OK 17:20:59.383 CNTRLR [Node 012] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 17:20:59.887 SERIAL » 0x010a00130c0370050125c47c (12 bytes) 17:20:59.888 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 196 └─[ConfigurationCCGet] parameter #: 1 17:20:59.890 SERIAL « [ACK] (0x06) 17:20:59.896 SERIAL « 0x0104011301e8 (6 bytes) 17:20:59.896 SERIAL » [ACK] (0x06) 17:20:59.897 DRIVER « [RES] [SendData] was sent: true 17:20:59.913 SERIAL « 0x01070013c40000022d (9 bytes) 17:20:59.913 SERIAL » [ACK] (0x06) 17:20:59.914 DRIVER « [REQ] [SendData] callback id: 196 transmit status: OK 17:21:01.522 SERIAL » 0x010a00130d0370050d25c570 (12 bytes) 17:21:01.524 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 197 └─[ConfigurationCCGet] parameter #: 13 17:21:01.525 CNTRLR « [Node 012] received no value for parameter #1 17:21:01.526 CNTRLR » [Node 012] querying parameter #2 value... 17:21:01.532 SERIAL « [ACK] (0x06) 17:21:01.534 SERIAL « 0x0104011301e8 (6 bytes) 17:21:01.535 SERIAL » [ACK] (0x06) 17:21:01.536 DRIVER « [RES] [SendData] was sent: true 17:21:01.579 SERIAL « 0x01070013c50000052b (9 bytes) 17:21:01.580 SERIAL » [ACK] (0x06) 17:21:01.581 DRIVER « [REQ] [SendData] callback id: 197 transmit status: OK 17:21:01.631 SERIAL « 0x010b0004000d0570060d010183 (13 bytes) 17:21:01.639 CNTRLR [Node 013] [~] [Configuration] 13: 1 => 1 17:21:01.640 SERIAL » [ACK] (0x06) 17:21:01.641 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 1 17:21:01.645 SERIAL » 0x010a00130e0370050d25c670 (12 bytes) 17:21:01.646 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 198 └─[ConfigurationCCGet] parameter #: 13 17:21:01.647 CNTRLR « [Node 013] parameter #13 has value: 1 17:21:01.647 CNTRLR » [Node 013] querying parameter #14 value... 17:21:01.651 SERIAL « [ACK] (0x06) 17:21:01.655 SERIAL « 0x0104011301e8 (6 bytes) 17:21:01.656 SERIAL » [ACK] (0x06) 17:21:01.657 DRIVER « [RES] [SendData] was sent: true 17:21:01.725 SERIAL « 0x01070013c60000072a (9 bytes) 17:21:01.726 SERIAL » [ACK] (0x06) 17:21:01.727 DRIVER « [REQ] [SendData] callback id: 198 transmit status: OK 17:21:01.736 SERIAL « 0x010b0004000e0570060d010180 (13 bytes) 17:21:01.744 CNTRLR [Node 014] [~] [Configuration] 13: 1 => 1 17:21:01.745 SERIAL » [ACK] (0x06) 17:21:01.746 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 1 17:21:01.751 SERIAL » 0x010a00130f0370052725c75a (12 bytes) 17:21:01.752 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 199 └─[ConfigurationCCGet] parameter #: 39 17:21:01.752 CNTRLR « [Node 014] parameter #13 has value: 1 17:21:01.753 CNTRLR » [Node 014] querying parameter #14 value... 17:21:01.757 SERIAL « [ACK] (0x06) 17:21:01.760 SERIAL « 0x0104011301e8 (6 bytes) 17:21:01.761 SERIAL » [ACK] (0x06) 17:21:01.762 DRIVER « [RES] [SendData] was sent: true 17:21:01.778 SERIAL « 0x01070013c70000022e (9 bytes) 17:21:01.779 SERIAL » [ACK] (0x06) 17:21:01.780 DRIVER « [REQ] [SendData] callback id: 199 transmit status: OK 17:21:01.788 SERIAL « 0x010c0004000f06700627020258f7 (14 bytes) 17:21:01.796 CNTRLR [Node 015] [~] [Configuration] 39: 600 => 600 17:21:01.797 SERIAL » [ACK] (0x06) 17:21:01.798 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 39 value size: 2 value: 600 17:21:01.802 SERIAL » 0x010a0013100370050125c86c (12 bytes) 17:21:01.803 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 200 └─[ConfigurationCCGet] parameter #: 1 17:21:01.803 CNTRLR « [Node 015] parameter #39 has value: 600 17:21:01.804 CNTRLR » [Node 015] querying parameter #40 value... 17:21:01.809 SERIAL « [ACK] (0x06) 17:21:01.811 SERIAL « 0x0104011301e8 (6 bytes) 17:21:01.812 SERIAL » [ACK] (0x06) 17:21:01.813 DRIVER « [RES] [SendData] was sent: true 17:21:01.849 SERIAL « 0x01070013c800000427 (9 bytes) 17:21:01.850 SERIAL » [ACK] (0x06) 17:21:01.850 DRIVER « [REQ] [SendData] callback id: 200 transmit status: OK 17:21:03.453 CNTRLR [Node 016] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 17:21:03.959 SERIAL » 0x010a0013100370050125c86c (12 bytes) 17:21:03.960 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 200 └─[ConfigurationCCGet] parameter #: 1 17:21:03.962 SERIAL « [ACK] (0x06) 17:21:03.968 SERIAL « 0x0104011301e8 (6 bytes) 17:21:03.969 SERIAL » [ACK] (0x06) 17:21:03.970 DRIVER « [RES] [SendData] was sent: true 17:21:04.007 SERIAL « 0x01070013c800000427 (9 bytes) 17:21:04.008 SERIAL » [ACK] (0x06) 17:21:04.009 DRIVER « [REQ] [SendData] callback id: 200 transmit status: OK 17:21:05.613 CNTRLR [Node 016] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 17:21:05.855 SERIAL « 0x010c0004000306310504220527c2 (14 bytes) 17:21:05.856 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:21:05.857 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 221.3 => 131.9 [Endpoint 0] 17:21:05.858 SERIAL » [ACK] (0x06) 17:21:05.859 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 131.9 17:21:06.119 SERIAL » 0x010a0013100370050125c86c (12 bytes) 17:21:06.120 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 200 └─[ConfigurationCCGet] parameter #: 1 17:21:06.123 SERIAL « [ACK] (0x06) 17:21:06.129 SERIAL « 0x0104011301e8 (6 bytes) 17:21:06.130 SERIAL » [ACK] (0x06) 17:21:06.131 DRIVER « [RES] [SendData] was sent: true 17:21:06.167 SERIAL « 0x01070013c800000427 (9 bytes) 17:21:06.168 SERIAL » [ACK] (0x06) 17:21:06.170 DRIVER « [REQ] [SendData] callback id: 200 transmit status: OK 17:21:07.776 SERIAL » 0x010a0013090370050f25c97a (12 bytes) 17:21:07.778 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 201 └─[ConfigurationCCGet] parameter #: 15 17:21:07.779 CNTRLR « [Node 016] received no value for parameter #1 17:21:07.780 CNTRLR » [Node 016] querying parameter #2 value... 17:21:07.783 SERIAL « [ACK] (0x06) 17:21:07.787 SERIAL « 0x0104011301e8 (6 bytes) 17:21:07.792 SERIAL » [ACK] (0x06) 17:21:07.793 DRIVER « [RES] [SendData] was sent: true 17:21:07.834 SERIAL « 0x01070013c900000527 (9 bytes) 17:21:07.834 SERIAL » [ACK] (0x06) 17:21:07.835 DRIVER « [REQ] [SendData] callback id: 201 transmit status: OK 17:21:07.887 SERIAL « 0x010b000400090570060f010084 (13 bytes) 17:21:07.892 CNTRLR [Node 009] [~] [Configuration] 15: 0 => 0 17:21:07.893 SERIAL » [ACK] (0x06) 17:21:07.893 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 15 value size: 1 value: 0 17:21:07.897 SERIAL » 0x010a00130c0370050225ca71 (12 bytes) 17:21:07.897 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 202 └─[ConfigurationCCGet] parameter #: 2 17:21:07.897 CNTRLR « [Node 009] parameter #15 has value: 0 17:21:07.898 CNTRLR » [Node 009] querying parameter #16 value... 17:21:07.901 SERIAL « [ACK] (0x06) 17:21:07.906 SERIAL « 0x0104011301e8 (6 bytes) 17:21:07.907 SERIAL » [ACK] (0x06) 17:21:07.907 DRIVER « [RES] [SendData] was sent: true 17:21:07.975 SERIAL « 0x01070013ca00000726 (9 bytes) 17:21:07.976 SERIAL » [ACK] (0x06) 17:21:07.982 DRIVER « [REQ] [SendData] callback id: 202 transmit status: OK 17:21:08.855 SERIAL « 0x010c000400030631050422094ea7 (14 bytes) 17:21:08.856 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:21:08.856 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 131.9 => 238.2 [Endpoint 0] 17:21:08.857 SERIAL » [ACK] (0x06) 17:21:08.858 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 238.2 17:21:09.584 CNTRLR [Node 012] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 17:21:09.856 SERIAL « 0x010c00040003063105042203ca29 (14 bytes) 17:21:09.857 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:21:09.858 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 238.2 => 97 [Endpoint 0] 17:21:09.859 SERIAL » [ACK] (0x06) 17:21:09.861 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 97 17:21:10.089 SERIAL » 0x010a00130c0370050225ca71 (12 bytes) 17:21:10.090 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 202 └─[ConfigurationCCGet] parameter #: 2 17:21:10.092 SERIAL « [ACK] (0x06) 17:21:10.099 SERIAL « 0x0104011301e8 (6 bytes) 17:21:10.099 SERIAL » [ACK] (0x06) 17:21:10.100 DRIVER « [RES] [SendData] was sent: true 17:21:10.116 SERIAL « 0x01070013ca00000223 (9 bytes) 17:21:10.117 SERIAL » [ACK] (0x06) 17:21:10.117 DRIVER « [REQ] [SendData] callback id: 202 transmit status: OK 17:21:10.855 SERIAL « 0x010c000400030631050422078b6c (14 bytes) 17:21:10.856 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:21:10.856 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 97 => 193.1 [Endpoint 0] 17:21:10.856 SERIAL » [ACK] (0x06) 17:21:10.857 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 193.1 17:21:11.722 CNTRLR [Node 012] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 17:21:11.855 SERIAL « 0x010c00040003063105042203b350 (14 bytes) 17:21:11.857 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:21:11.857 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 193.1 => 94.7 [Endpoint 0] 17:21:11.858 SERIAL » [ACK] (0x06) 17:21:11.860 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 94.7 17:21:12.229 SERIAL » 0x010a00130c0370050225ca71 (12 bytes) 17:21:12.231 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 202 └─[ConfigurationCCGet] parameter #: 2 17:21:12.234 SERIAL « [ACK] (0x06) 17:21:12.240 SERIAL « 0x0104011301e8 (6 bytes) 17:21:12.241 SERIAL » [ACK] (0x06) 17:21:12.242 DRIVER « [RES] [SendData] was sent: true 17:21:12.257 SERIAL « 0x01070013ca00000223 (9 bytes) 17:21:12.258 SERIAL » [ACK] (0x06) 17:21:12.259 DRIVER « [REQ] [SendData] callback id: 202 transmit status: OK 17:21:13.855 SERIAL « 0x010c000400030631050422087991 (14 bytes) 17:21:13.856 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:21:13.856 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 94.7 => 216.9 [Endpoint 0] 17:21:13.857 SERIAL » [ACK] (0x06) 17:21:13.858 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 216.9 17:21:13.866 SERIAL » 0x010a00130d0370050e25cb7d (12 bytes) 17:21:13.866 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 203 └─[ConfigurationCCGet] parameter #: 14 17:21:13.867 CNTRLR « [Node 012] received no value for parameter #2 17:21:13.867 CNTRLR » [Node 012] querying parameter #3 value... 17:21:13.873 SERIAL « [ACK] (0x06) 17:21:13.874 SERIAL « 0x0104011301e8 (6 bytes) 17:21:13.875 SERIAL » [ACK] (0x06) 17:21:13.875 DRIVER « [RES] [SendData] was sent: true 17:21:13.921 SERIAL « 0x01070013cb00000525 (9 bytes) 17:21:13.921 SERIAL » [ACK] (0x06) 17:21:13.922 DRIVER « [REQ] [SendData] callback id: 203 transmit status: OK 17:21:13.972 SERIAL « 0x010b0004000d0570060e010081 (13 bytes) 17:21:13.977 CNTRLR [Node 013] [~] [Configuration] 14: 0 => 0 17:21:13.978 SERIAL » [ACK] (0x06) 17:21:13.979 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 0 17:21:13.982 SERIAL » 0x010a00130e0370050e25cc79 (12 bytes) 17:21:13.983 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 204 └─[ConfigurationCCGet] parameter #: 14 17:21:13.983 CNTRLR « [Node 013] parameter #14 has value: 0 17:21:13.983 CNTRLR » [Node 013] querying parameter #17 value... 17:21:13.987 SERIAL « [ACK] (0x06) 17:21:13.991 SERIAL « 0x0104011301e8 (6 bytes) 17:21:13.992 SERIAL » [ACK] (0x06) 17:21:13.992 DRIVER « [RES] [SendData] was sent: true 17:21:14.065 SERIAL « 0x01070013cc0000082f (9 bytes) 17:21:14.066 SERIAL » [ACK] (0x06) 17:21:14.066 DRIVER « [REQ] [SendData] callback id: 204 transmit status: OK 17:21:14.076 SERIAL « 0x010b0004000e0570060e010082 (13 bytes) 17:21:14.081 CNTRLR [Node 014] [~] [Configuration] 14: 0 => 0 17:21:14.082 SERIAL » [ACK] (0x06) 17:21:14.083 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 0 17:21:14.086 SERIAL » 0x010a00130f0370052825cd5f (12 bytes) 17:21:14.087 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 205 └─[ConfigurationCCGet] parameter #: 40 17:21:14.087 CNTRLR « [Node 014] parameter #14 has value: 0 17:21:14.087 CNTRLR » [Node 014] querying parameter #17 value... 17:21:14.091 SERIAL « [ACK] (0x06) 17:21:14.095 SERIAL « 0x0104011301e8 (6 bytes) 17:21:14.095 SERIAL » [ACK] (0x06) 17:21:14.096 DRIVER « [RES] [SendData] was sent: true 17:21:14.112 SERIAL « 0x01070013cd00000224 (9 bytes) 17:21:14.112 SERIAL » [ACK] (0x06) 17:21:14.113 DRIVER « [REQ] [SendData] callback id: 205 transmit status: OK 17:21:14.123 SERIAL « 0x010b0004000f057006280150f5 (13 bytes) 17:21:14.130 CNTRLR [Node 015] [~] [Configuration] 40: 80 => 80 17:21:14.131 SERIAL » [ACK] (0x06) 17:21:14.132 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 80 17:21:14.135 SERIAL » 0x010a0013100370050225ce69 (12 bytes) 17:21:14.136 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 206 └─[ConfigurationCCGet] parameter #: 2 17:21:14.136 CNTRLR « [Node 015] parameter #40 has value: 80 17:21:14.137 CNTRLR » [Node 015] querying parameter #42 value... 17:21:14.140 SERIAL « [ACK] (0x06) 17:21:14.145 SERIAL « 0x0104011301e8 (6 bytes) 17:21:14.145 SERIAL » [ACK] (0x06) 17:21:14.146 DRIVER « [RES] [SendData] was sent: true 17:21:14.182 SERIAL « 0x01070013ce00000520 (9 bytes) 17:21:14.183 SERIAL » [ACK] (0x06) 17:21:14.183 DRIVER « [REQ] [SendData] callback id: 206 transmit status: OK 17:21:15.786 CNTRLR [Node 016] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 17:21:16.292 SERIAL » 0x010a0013100370050225ce69 (12 bytes) 17:21:16.293 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 206 └─[ConfigurationCCGet] parameter #: 2 17:21:16.295 SERIAL « [ACK] (0x06) 17:21:16.301 SERIAL « 0x0104011301e8 (6 bytes) 17:21:16.302 SERIAL » [ACK] (0x06) 17:21:16.303 DRIVER « [RES] [SendData] was sent: true 17:21:16.340 SERIAL « 0x01070013ce00000520 (9 bytes) 17:21:16.341 SERIAL » [ACK] (0x06) 17:21:16.342 DRIVER « [REQ] [SendData] callback id: 206 transmit status: OK 17:21:17.580 SERIAL « 0x01090004001b033003ff26 (11 bytes) 17:21:17.582 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:21:17.583 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:21:17.584 SERIAL » [ACK] (0x06) 17:21:17.586 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:21:17.635 SERIAL « 0x01090004001b032001ff34 (11 bytes) 17:21:17.636 SERIAL » [ACK] (0x06) 17:21:17.637 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:21:17.639 CNTRLR [Node 027] treating BasicCC Set as a report 17:21:17.639 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:21:17.948 CNTRLR [Node 016] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 17:21:18.453 SERIAL » 0x010a0013100370050225ce69 (12 bytes) 17:21:18.454 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 206 └─[ConfigurationCCGet] parameter #: 2 17:21:18.456 SERIAL « [ACK] (0x06) 17:21:18.463 SERIAL « 0x0104011301e8 (6 bytes) 17:21:18.463 SERIAL » [ACK] (0x06) 17:21:18.464 DRIVER « [RES] [SendData] was sent: true 17:21:18.501 SERIAL « 0x01070013ce00000520 (9 bytes) 17:21:18.502 SERIAL » [ACK] (0x06) 17:21:18.503 DRIVER « [REQ] [SendData] callback id: 206 transmit status: OK 17:21:20.112 SERIAL » 0x010a0013090370051025cf63 (12 bytes) 17:21:20.112 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 207 └─[ConfigurationCCGet] parameter #: 16 17:21:20.113 CNTRLR « [Node 016] received no value for parameter #2 17:21:20.113 CNTRLR » [Node 016] querying parameter #3 value... 17:21:20.116 SERIAL « [ACK] (0x06) 17:21:20.120 SERIAL « 0x0104011301e8 (6 bytes) 17:21:20.121 SERIAL » [ACK] (0x06) 17:21:20.121 DRIVER « [RES] [SendData] was sent: true 17:21:20.167 SERIAL « 0x01070013cf00000521 (9 bytes) 17:21:20.167 SERIAL » [ACK] (0x06) 17:21:20.168 DRIVER « [REQ] [SendData] callback id: 207 transmit status: OK 17:21:20.220 SERIAL « 0x010b000400090570061001019a (13 bytes) 17:21:20.225 CNTRLR [Node 009] [~] [Configuration] 16: 1 => 1 17:21:20.226 SERIAL » [ACK] (0x06) 17:21:20.227 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 1 17:21:20.230 SERIAL » 0x010a00130c0370050325d06a (12 bytes) 17:21:20.230 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 208 └─[ConfigurationCCGet] parameter #: 3 17:21:20.231 CNTRLR « [Node 009] parameter #16 has value: 1 17:21:20.231 CNTRLR » [Node 009] querying parameter #30 value... 17:21:20.234 SERIAL « [ACK] (0x06) 17:21:20.239 SERIAL « 0x0104011301e8 (6 bytes) 17:21:20.239 SERIAL » [ACK] (0x06) 17:21:20.240 DRIVER « [RES] [SendData] was sent: true 17:21:20.316 SERIAL « 0x01070013d000000833 (9 bytes) 17:21:20.317 SERIAL » [ACK] (0x06) 17:21:20.317 DRIVER « [REQ] [SendData] callback id: 208 transmit status: OK 17:21:20.326 SERIAL « 0x010b0004000c0570060301008d (13 bytes) 17:21:20.331 CNTRLR [Node 012] [~] [Configuration] 3: 0 => 0 17:21:20.332 SERIAL » [ACK] (0x06) 17:21:20.333 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 17:21:20.336 SERIAL » 0x010a00130d0370051125d178 (12 bytes) 17:21:20.336 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 209 └─[ConfigurationCCGet] parameter #: 17 17:21:20.337 CNTRLR « [Node 012] parameter #3 has value: 0 17:21:20.337 CNTRLR » [Node 012] querying parameter #10 value... 17:21:20.340 SERIAL « [ACK] (0x06) 17:21:20.345 SERIAL « 0x0104011301e8 (6 bytes) 17:21:20.345 SERIAL » [ACK] (0x06) 17:21:20.346 DRIVER « [RES] [SendData] was sent: true 17:21:20.391 SERIAL « 0x01070013d10000053f (9 bytes) 17:21:20.391 SERIAL » [ACK] (0x06) 17:21:20.392 DRIVER « [REQ] [SendData] callback id: 209 transmit status: OK 17:21:20.443 SERIAL « 0x010b0004000d05700611010a94 (13 bytes) 17:21:20.448 CNTRLR [Node 013] [~] [Configuration] 17: 10 => 10 17:21:20.449 SERIAL » [ACK] (0x06) 17:21:20.450 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 17 value size: 1 value: 10 17:21:20.453 SERIAL » 0x010a00130e0370051125d278 (12 bytes) 17:21:20.453 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 210 └─[ConfigurationCCGet] parameter #: 17 17:21:20.454 CNTRLR « [Node 013] parameter #17 has value: 10 17:21:20.454 CNTRLR » [Node 013] querying parameter #18 value... 17:21:20.458 SERIAL « [ACK] (0x06) 17:21:20.462 SERIAL « 0x0104011301e8 (6 bytes) 17:21:20.462 SERIAL » [ACK] (0x06) 17:21:20.463 DRIVER « [RES] [SendData] was sent: true 17:21:20.535 SERIAL « 0x01070013d200000831 (9 bytes) 17:21:20.536 SERIAL » [ACK] (0x06) 17:21:20.537 DRIVER « [REQ] [SendData] callback id: 210 transmit status: OK 17:21:20.546 SERIAL « 0x010b0004000e05700611010a97 (13 bytes) 17:21:20.556 CNTRLR [Node 014] [~] [Configuration] 17: 10 => 10 17:21:20.563 SERIAL » [ACK] (0x06) 17:21:20.565 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 17 value size: 1 value: 10 17:21:20.571 SERIAL » 0x010a00130f0370052a25d343 (12 bytes) 17:21:20.571 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 211 └─[ConfigurationCCGet] parameter #: 42 17:21:20.572 CNTRLR « [Node 014] parameter #17 has value: 10 17:21:20.572 CNTRLR » [Node 014] querying parameter #18 value... 17:21:20.579 SERIAL « [ACK] (0x06) 17:21:20.581 SERIAL « 0x0104011301e8 (6 bytes) 17:21:20.582 SERIAL » [ACK] (0x06) 17:21:20.583 DRIVER « [RES] [SendData] was sent: true 17:21:20.597 SERIAL « 0x01070013d30000023a (9 bytes) 17:21:20.598 SERIAL » [ACK] (0x06) 17:21:20.599 DRIVER « [REQ] [SendData] callback id: 211 transmit status: OK 17:21:20.607 SERIAL « 0x010b0004000f0570062a010fa8 (13 bytes) 17:21:20.625 CNTRLR [Node 015] [~] [Configuration] 42: 15 => 15 17:21:20.626 SERIAL » [ACK] (0x06) 17:21:20.627 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 15 17:21:20.646 SERIAL » 0x010a0013100370050325d472 (12 bytes) 17:21:20.648 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 212 └─[ConfigurationCCGet] parameter #: 3 17:21:20.648 CNTRLR « [Node 015] parameter #42 has value: 15 17:21:20.650 CNTRLR » [Node 015] querying parameter #43 value... 17:21:20.665 SERIAL « [ACK] (0x06) 17:21:20.667 SERIAL « 0x0104011301e8 (6 bytes) 17:21:20.667 SERIAL » [ACK] (0x06) 17:21:20.668 DRIVER « [RES] [SendData] was sent: true 17:21:20.694 SERIAL « 0x01070013d40000043b (9 bytes) 17:21:20.695 SERIAL » [ACK] (0x06) 17:21:20.696 DRIVER « [REQ] [SendData] callback id: 212 transmit status: OK 17:21:20.743 SERIAL « 0x010b0004001005700603010091 (13 bytes) 17:21:20.750 CNTRLR [Node 016] [~] [Configuration] 3: 0 => 0 17:21:20.751 SERIAL » [ACK] (0x06) 17:21:20.752 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 17:21:20.757 SERIAL » 0x010a0013090370051e25d577 (12 bytes) 17:21:20.758 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 213 └─[ConfigurationCCGet] parameter #: 30 17:21:20.758 CNTRLR « [Node 016] parameter #3 has value: 0 17:21:20.759 CNTRLR » [Node 016] querying parameter #10 value... 17:21:20.763 SERIAL « [ACK] (0x06) 17:21:20.766 SERIAL « 0x0104011301e8 (6 bytes) 17:21:20.767 SERIAL » [ACK] (0x06) 17:21:20.768 DRIVER « [RES] [SendData] was sent: true 17:21:20.855 SERIAL « 0x01070013d500000937 (9 bytes) 17:21:20.855 SERIAL » [ACK] (0x06) 17:21:20.856 DRIVER « [REQ] [SendData] callback id: 213 transmit status: OK 17:21:20.908 SERIAL « 0x010b000400090570061e010396 (13 bytes) 17:21:20.915 CNTRLR [Node 009] [~] [Configuration] 30: 3 => 3 17:21:20.916 SERIAL » [ACK] (0x06) 17:21:20.917 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 3 17:21:20.922 SERIAL » 0x010a00130c0370050a25d665 (12 bytes) 17:21:20.922 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 214 └─[ConfigurationCCGet] parameter #: 10 17:21:20.923 CNTRLR « [Node 009] parameter #30 has value: 3 17:21:20.923 CNTRLR » [Node 009] querying parameter #31 value... 17:21:20.928 SERIAL « [ACK] (0x06) 17:21:20.933 SERIAL « 0x0104011301e8 (6 bytes) 17:21:20.934 SERIAL » [ACK] (0x06) 17:21:20.935 DRIVER « [RES] [SendData] was sent: true 17:21:20.995 SERIAL « 0x01070013d60000073a (9 bytes) 17:21:20.996 SERIAL » [ACK] (0x06) 17:21:20.997 DRIVER « [REQ] [SendData] callback id: 214 transmit status: OK 17:21:21.010 SERIAL « 0x010b0004000c0570060a010185 (13 bytes) 17:21:21.017 CNTRLR [Node 012] [~] [Configuration] 10: 1 => 1 17:21:21.018 SERIAL » [ACK] (0x06) 17:21:21.019 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 1 17:21:21.023 SERIAL » 0x010a00130d0370051225d77d (12 bytes) 17:21:21.024 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 215 └─[ConfigurationCCGet] parameter #: 18 17:21:21.024 CNTRLR « [Node 012] parameter #10 has value: 1 17:21:21.025 CNTRLR » [Node 012] querying parameter #12 value... 17:21:21.029 SERIAL « [ACK] (0x06) 17:21:21.033 SERIAL « 0x0104011301e8 (6 bytes) 17:21:21.033 SERIAL » [ACK] (0x06) 17:21:21.034 DRIVER « [RES] [SendData] was sent: true 17:21:21.078 SERIAL « 0x01070013d700000539 (9 bytes) 17:21:21.079 SERIAL » [ACK] (0x06) 17:21:21.080 DRIVER « [REQ] [SendData] callback id: 215 transmit status: OK 17:21:21.131 SERIAL « 0x010b0004000d05700612010a97 (13 bytes) 17:21:21.138 CNTRLR [Node 013] [~] [Configuration] 18: 10 => 10 17:21:21.139 SERIAL » [ACK] (0x06) 17:21:21.140 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 18 value size: 1 value: 10 17:21:21.149 SERIAL » 0x010a00130e0370051225d871 (12 bytes) 17:21:21.150 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 216 └─[ConfigurationCCGet] parameter #: 18 17:21:21.151 CNTRLR « [Node 013] parameter #18 has value: 10 17:21:21.151 CNTRLR » [Node 013] querying parameter #22 value... 17:21:21.156 SERIAL « [ACK] (0x06) 17:21:21.158 SERIAL « 0x0104011301e8 (6 bytes) 17:21:21.159 SERIAL » [ACK] (0x06) 17:21:21.160 DRIVER « [RES] [SendData] was sent: true 17:21:21.216 SERIAL « 0x01070013d800000635 (9 bytes) 17:21:21.216 SERIAL » [ACK] (0x06) 17:21:21.217 DRIVER « [REQ] [SendData] callback id: 216 transmit status: OK 17:21:21.226 SERIAL « 0x010b0004000e05700612010a94 (13 bytes) 17:21:21.236 CNTRLR [Node 014] [~] [Configuration] 18: 10 => 10 17:21:21.237 SERIAL » [ACK] (0x06) 17:21:21.239 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 18 value size: 1 value: 10 17:21:21.244 SERIAL » 0x010a00130f0370052b25d948 (12 bytes) 17:21:21.245 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 217 └─[ConfigurationCCGet] parameter #: 43 17:21:21.246 CNTRLR « [Node 014] parameter #18 has value: 10 17:21:21.246 CNTRLR » [Node 014] querying parameter #22 value... 17:21:21.250 SERIAL « [ACK] (0x06) 17:21:21.254 SERIAL « 0x0104011301e8 (6 bytes) 17:21:21.254 SERIAL » [ACK] (0x06) 17:21:21.255 DRIVER « [RES] [SendData] was sent: true 17:21:21.271 SERIAL « 0x01070013d900000331 (9 bytes) 17:21:21.271 SERIAL » [ACK] (0x06) 17:21:21.272 DRIVER « [REQ] [SendData] callback id: 217 transmit status: OK 17:21:21.281 SERIAL « 0x010b0004000f0570062b011eb8 (13 bytes) 17:21:21.286 CNTRLR [Node 015] [~] [Configuration] 43: 30 => 30 17:21:21.287 SERIAL » [ACK] (0x06) 17:21:21.288 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 30 17:21:21.291 SERIAL » 0x010a0013100370050a25da75 (12 bytes) 17:21:21.291 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 218 └─[ConfigurationCCGet] parameter #: 10 17:21:21.292 CNTRLR « [Node 015] parameter #43 has value: 30 17:21:21.292 CNTRLR » [Node 015] querying parameter #45 value... 17:21:21.295 SERIAL « [ACK] (0x06) 17:21:21.299 SERIAL « 0x0104011301e8 (6 bytes) 17:21:21.300 SERIAL » [ACK] (0x06) 17:21:21.301 DRIVER « [RES] [SendData] was sent: true 17:21:21.338 SERIAL « 0x01070013da00000435 (9 bytes) 17:21:21.339 SERIAL » [ACK] (0x06) 17:21:21.342 DRIVER « [REQ] [SendData] callback id: 218 transmit status: OK 17:21:21.387 SERIAL « 0x010b000400100570060a010199 (13 bytes) 17:21:21.392 CNTRLR [Node 016] [~] [Configuration] 10: 1 => 1 17:21:21.392 SERIAL » [ACK] (0x06) 17:21:21.393 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 1 17:21:21.396 SERIAL » 0x010a0013090370051f25db78 (12 bytes) 17:21:21.397 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 219 └─[ConfigurationCCGet] parameter #: 31 17:21:21.397 CNTRLR « [Node 016] parameter #10 has value: 1 17:21:21.397 CNTRLR » [Node 016] querying parameter #12 value... 17:21:21.401 SERIAL « [ACK] (0x06) 17:21:21.405 SERIAL « 0x0104011301e8 (6 bytes) 17:21:21.406 SERIAL » [ACK] (0x06) 17:21:21.407 DRIVER « [RES] [SendData] was sent: true 17:21:21.505 SERIAL « 0x01070013db00000a3a (9 bytes) 17:21:21.505 SERIAL » [ACK] (0x06) 17:21:21.506 DRIVER « [REQ] [SendData] callback id: 219 transmit status: OK 17:21:21.558 SERIAL « 0x010b000400090570061f010296 (13 bytes) 17:21:21.567 CNTRLR [Node 009] [~] [Configuration] 31: 2 => 2 17:21:21.568 SERIAL » [ACK] (0x06) 17:21:21.569 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 2 17:21:21.572 SERIAL » 0x010a00130c0370050c25dc69 (12 bytes) 17:21:21.572 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 220 └─[ConfigurationCCGet] parameter #: 12 17:21:21.573 CNTRLR « [Node 009] parameter #31 has value: 2 17:21:21.573 CNTRLR » [Node 009] querying parameter #32 value... 17:21:21.576 SERIAL « [ACK] (0x06) 17:21:21.582 SERIAL « 0x0104011301e8 (6 bytes) 17:21:21.583 SERIAL » [ACK] (0x06) 17:21:21.583 DRIVER « [RES] [SendData] was sent: true 17:21:21.646 SERIAL « 0x01090004001e033003ff23 (11 bytes) 17:21:21.647 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:21:21.647 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:21:21.648 SERIAL » [ACK] (0x06) 17:21:21.649 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:21:21.728 SERIAL « 0x010c0004000c0670060c02009613 (14 bytes) 17:21:21.733 CNTRLR [Node 012] [~] [Configuration] 12: 150 => 150 17:21:21.734 SERIAL » [ACK] (0x06) 17:21:21.735 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 150 17:21:21.759 SERIAL « 0x01070013dc00001324 (9 bytes) 17:21:21.759 SERIAL » [ACK] (0x06) 17:21:21.760 DRIVER « [REQ] [SendData] callback id: 220 transmit status: OK 17:21:21.770 SERIAL « 0x010c0004000c0670060c02009613 (14 bytes) 17:21:21.775 CNTRLR [Node 012] [~] [Configuration] 12: 150 => 150 17:21:21.776 SERIAL » [ACK] (0x06) 17:21:21.777 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 150 17:21:21.782 SERIAL » 0x010a00130d0370051625dd73 (12 bytes) 17:21:21.782 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 221 └─[ConfigurationCCGet] parameter #: 22 17:21:21.783 CNTRLR « [Node 012] parameter #12 has value: 150 17:21:21.783 CNTRLR » [Node 012] querying parameter #13 value... 17:21:21.786 SERIAL « [ACK] (0x06) 17:21:21.791 SERIAL « 0x0104011301e8 (6 bytes) 17:21:21.792 SERIAL » [ACK] (0x06) 17:21:21.793 DRIVER « [RES] [SendData] was sent: true 17:21:21.837 SERIAL « 0x01070013dd00000533 (9 bytes) 17:21:21.838 SERIAL » [ACK] (0x06) 17:21:21.838 DRIVER « [REQ] [SendData] callback id: 221 transmit status: OK 17:21:21.889 SERIAL « 0x010c0004000d067006160200f06e (14 bytes) 17:21:21.895 CNTRLR [Node 013] [~] [Configuration] 22: 240 => 240 17:21:21.895 SERIAL » [ACK] (0x06) 17:21:21.896 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 240 17:21:21.901 SERIAL » 0x010a00130e0370051625de73 (12 bytes) 17:21:21.902 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 222 └─[ConfigurationCCGet] parameter #: 22 17:21:21.902 CNTRLR « [Node 013] parameter #22 has value: 240 17:21:21.903 CNTRLR » [Node 013] querying parameter #29 value... 17:21:21.906 SERIAL « [ACK] (0x06) 17:21:21.910 SERIAL « 0x0104011301e8 (6 bytes) 17:21:21.911 SERIAL » [ACK] (0x06) 17:21:21.911 DRIVER « [RES] [SendData] was sent: true 17:21:21.986 SERIAL « 0x01070013de0000083d (9 bytes) 17:21:21.987 SERIAL » [ACK] (0x06) 17:21:21.989 DRIVER « [REQ] [SendData] callback id: 222 transmit status: OK 17:21:21.997 SERIAL « 0x010c0004000e067006160200f06d (14 bytes) 17:21:22.009 CNTRLR [Node 014] [~] [Configuration] 22: 240 => 240 17:21:22.010 SERIAL » [ACK] (0x06) 17:21:22.012 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 240 17:21:22.017 SERIAL » 0x010a00130f0370052d25df48 (12 bytes) 17:21:22.018 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 223 └─[ConfigurationCCGet] parameter #: 45 17:21:22.019 CNTRLR « [Node 014] parameter #22 has value: 240 17:21:22.019 CNTRLR » [Node 014] querying parameter #29 value... 17:21:22.025 SERIAL « [ACK] (0x06) 17:21:22.029 SERIAL « 0x0104011301e8 (6 bytes) 17:21:22.030 SERIAL » [ACK] (0x06) 17:21:22.032 DRIVER « [RES] [SendData] was sent: true 17:21:22.044 SERIAL « 0x01070013df00000236 (9 bytes) 17:21:22.045 SERIAL » [ACK] (0x06) 17:21:22.046 DRIVER « [REQ] [SendData] callback id: 223 transmit status: OK 17:21:22.055 SERIAL « 0x010b0004000f0570062d010aaa (13 bytes) 17:21:22.061 CNTRLR [Node 015] [~] [Configuration] 45: 10 => 10 17:21:22.062 SERIAL » [ACK] (0x06) 17:21:22.062 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 45 value size: 1 value: 10 17:21:22.066 SERIAL » 0x010a0013100370050c25e049 (12 bytes) 17:21:22.066 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 224 └─[ConfigurationCCGet] parameter #: 12 17:21:22.067 CNTRLR « [Node 015] parameter #45 has value: 10 17:21:22.067 CNTRLR » [Node 015] querying parameter #47 value... 17:21:22.071 SERIAL « [ACK] (0x06) 17:21:22.075 SERIAL « 0x0104011301e8 (6 bytes) 17:21:22.076 SERIAL » [ACK] (0x06) 17:21:22.077 DRIVER « [RES] [SendData] was sent: true 17:21:22.113 SERIAL « 0x01070013e00000040f (9 bytes) 17:21:22.113 SERIAL » [ACK] (0x06) 17:21:22.114 DRIVER « [REQ] [SendData] callback id: 224 transmit status: OK 17:21:22.161 SERIAL « 0x010c000400100670060c0200960f (14 bytes) 17:21:22.166 CNTRLR [Node 016] [~] [Configuration] 12: 150 => 150 17:21:22.167 SERIAL » [ACK] (0x06) 17:21:22.168 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 150 17:21:22.171 SERIAL » 0x010a0013090370052025e17d (12 bytes) 17:21:22.171 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 225 └─[ConfigurationCCGet] parameter #: 32 17:21:22.172 CNTRLR « [Node 016] parameter #12 has value: 150 17:21:22.172 CNTRLR » [Node 016] querying parameter #13 value... 17:21:22.175 SERIAL « [ACK] (0x06) 17:21:22.181 SERIAL « 0x0104011301e8 (6 bytes) 17:21:22.181 SERIAL » [ACK] (0x06) 17:21:22.182 DRIVER « [RES] [SendData] was sent: true 17:21:22.275 SERIAL « 0x01070013e100000a00 (9 bytes) 17:21:22.275 SERIAL » [ACK] (0x06) 17:21:22.276 DRIVER « [REQ] [SendData] callback id: 225 transmit status: OK 17:21:22.326 SERIAL « 0x010b00040009057006200103a8 (13 bytes) 17:21:22.331 CNTRLR [Node 009] [~] [Configuration] 32: 3 => 3 17:21:22.331 SERIAL » [ACK] (0x06) 17:21:22.332 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 1 value: 3 17:21:22.336 SERIAL » 0x010a00130c0370050d25e256 (12 bytes) 17:21:22.336 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 226 └─[ConfigurationCCGet] parameter #: 13 17:21:22.336 CNTRLR « [Node 009] parameter #32 has value: 3 17:21:22.337 CNTRLR » [Node 009] querying parameter #33 value... 17:21:22.340 SERIAL « [ACK] (0x06) 17:21:22.345 SERIAL « 0x0104011301e8 (6 bytes) 17:21:22.345 SERIAL » [ACK] (0x06) 17:21:22.346 DRIVER « [RES] [SendData] was sent: true 17:21:22.415 SERIAL « 0x01070013e200000801 (9 bytes) 17:21:22.416 SERIAL » [ACK] (0x06) 17:21:22.416 DRIVER « [REQ] [SendData] callback id: 226 transmit status: OK 17:21:22.424 SERIAL « 0x010b0004000c0570060d010182 (13 bytes) 17:21:22.430 CNTRLR [Node 012] [~] [Configuration] 13: 1 => 1 17:21:22.430 SERIAL » [ACK] (0x06) 17:21:22.431 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 1 17:21:22.434 SERIAL » 0x010a00130d0370051d25e346 (12 bytes) 17:21:22.435 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 227 └─[ConfigurationCCGet] parameter #: 29 17:21:22.435 CNTRLR « [Node 012] parameter #13 has value: 1 17:21:22.435 CNTRLR » [Node 012] querying parameter #14 value... 17:21:22.442 SERIAL « [ACK] (0x06) 17:21:22.444 SERIAL « 0x0104011301e8 (6 bytes) 17:21:22.445 SERIAL » [ACK] (0x06) 17:21:22.446 DRIVER « [RES] [SendData] was sent: true 17:21:22.450 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 17:21:22.451 SERIAL » [ACK] (0x06) 17:21:22.452 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 17:21:22.454 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 17:21:22.531 SERIAL « 0x01070013e300000a02 (9 bytes) 17:21:22.531 SERIAL » [ACK] (0x06) 17:21:22.532 DRIVER « [REQ] [SendData] callback id: 227 transmit status: OK 17:21:22.568 SERIAL « 0x010b0004000c0570060d010182 (13 bytes) 17:21:22.573 CNTRLR [Node 012] [~] [Configuration] 13: 1 => 1 17:21:22.574 SERIAL » [ACK] (0x06) 17:21:22.574 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 1 17:21:22.583 SERIAL « 0x010b0004000d0570061d010092 (13 bytes) 17:21:22.588 CNTRLR [Node 013] [~] [Configuration] 29: 0 => 0 17:21:22.589 SERIAL » [ACK] (0x06) 17:21:22.590 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 29 value size: 1 value: 0 17:21:22.593 SERIAL » 0x010a00130e0370051d25e442 (12 bytes) 17:21:22.593 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 228 └─[ConfigurationCCGet] parameter #: 29 17:21:22.594 CNTRLR « [Node 013] parameter #29 has value: 0 17:21:22.594 CNTRLR » [Node 013] querying parameter #30 value... 17:21:22.598 SERIAL « [ACK] (0x06) 17:21:22.603 SERIAL « 0x0104011301e8 (6 bytes) 17:21:22.603 SERIAL » [ACK] (0x06) 17:21:22.604 DRIVER « [RES] [SendData] was sent: true 17:21:22.685 SERIAL « 0x01070013e400000906 (9 bytes) 17:21:22.686 SERIAL » [ACK] (0x06) 17:21:22.686 DRIVER « [REQ] [SendData] callback id: 228 transmit status: OK 17:21:22.696 SERIAL « 0x010b0004000e0570061d010091 (13 bytes) 17:21:22.701 CNTRLR [Node 014] [~] [Configuration] 29: 0 => 0 17:21:22.702 SERIAL » [ACK] (0x06) 17:21:22.703 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 29 value size: 1 value: 0 17:21:22.707 SERIAL » 0x010a00130f0370052f25e570 (12 bytes) 17:21:22.707 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 229 └─[ConfigurationCCGet] parameter #: 47 17:21:22.708 CNTRLR « [Node 014] parameter #29 has value: 0 17:21:22.708 CNTRLR » [Node 014] querying parameter #30 value... 17:21:22.714 SERIAL « [ACK] (0x06) 17:21:22.716 SERIAL « 0x0104011301e8 (6 bytes) 17:21:22.716 SERIAL » [ACK] (0x06) 17:21:22.717 DRIVER « [RES] [SendData] was sent: true 17:21:22.733 SERIAL « 0x01070013e50000020c (9 bytes) 17:21:22.733 SERIAL » [ACK] (0x06) 17:21:22.733 DRIVER « [REQ] [SendData] callback id: 229 transmit status: OK 17:21:22.743 SERIAL « 0x010c0004000f0670062f020e10bb (14 bytes) 17:21:22.748 CNTRLR [Node 015] [~] [Configuration] 47: 3600 => 3600 17:21:22.749 SERIAL » [ACK] (0x06) 17:21:22.750 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 47 value size: 2 value: 3600 17:21:22.753 SERIAL » 0x010a0013100370050d25e64e (12 bytes) 17:21:22.754 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 230 └─[ConfigurationCCGet] parameter #: 13 17:21:22.754 CNTRLR « [Node 015] parameter #47 has value: 3600 17:21:22.754 CNTRLR » [Node 015] querying parameter #49 value... 17:21:22.760 SERIAL « [ACK] (0x06) 17:21:22.763 SERIAL « 0x0104011301e8 (6 bytes) 17:21:22.764 SERIAL » [ACK] (0x06) 17:21:22.768 DRIVER « [RES] [SendData] was sent: true 17:21:22.800 SERIAL « 0x01070013e600000508 (9 bytes) 17:21:22.801 SERIAL » [ACK] (0x06) 17:21:22.802 DRIVER « [REQ] [SendData] callback id: 230 transmit status: OK 17:21:22.849 SERIAL « 0x010b000400100570060d01019e (13 bytes) 17:21:22.859 CNTRLR [Node 016] [~] [Configuration] 13: 1 => 1 17:21:22.860 SERIAL » [ACK] (0x06) 17:21:22.862 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 1 17:21:22.868 SERIAL » 0x010a0013090370052125e77a (12 bytes) 17:21:22.872 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 231 └─[ConfigurationCCGet] parameter #: 33 17:21:22.875 CNTRLR « [Node 016] parameter #13 has value: 1 17:21:22.876 CNTRLR » [Node 016] querying parameter #14 value... 17:21:22.882 SERIAL « [ACK] (0x06) 17:21:22.890 SERIAL « 0x0104011301e8 (6 bytes) 17:21:22.891 SERIAL » [ACK] (0x06) 17:21:22.892 DRIVER « [RES] [SendData] was sent: true 17:21:22.965 SERIAL « 0x01070013e700000905 (9 bytes) 17:21:22.966 SERIAL » [ACK] (0x06) 17:21:22.967 DRIVER « [REQ] [SendData] callback id: 231 transmit status: OK 17:21:23.018 SERIAL « 0x010b00040009057006210101ab (13 bytes) 17:21:23.026 CNTRLR [Node 009] [~] [Configuration] 33: 1 => 1 17:21:23.027 SERIAL » [ACK] (0x06) 17:21:23.034 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 1 value: 1 17:21:23.038 SERIAL » 0x010a00130c0370050e25e85f (12 bytes) 17:21:23.039 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 232 └─[ConfigurationCCGet] parameter #: 14 17:21:23.039 CNTRLR « [Node 009] parameter #33 has value: 1 17:21:23.039 CNTRLR » [Node 009] querying parameter #39 value... 17:21:23.044 SERIAL « [ACK] (0x06) 17:21:23.048 SERIAL « 0x0104011301e8 (6 bytes) 17:21:23.049 SERIAL » [ACK] (0x06) 17:21:23.050 DRIVER « [RES] [SendData] was sent: true 17:21:23.105 SERIAL « 0x01070013e800000605 (9 bytes) 17:21:23.106 SERIAL » [ACK] (0x06) 17:21:23.107 DRIVER « [REQ] [SendData] callback id: 232 transmit status: OK 17:21:23.116 SERIAL « 0x010b0004000c0570060e010080 (13 bytes) 17:21:23.123 CNTRLR [Node 012] [~] [Configuration] 14: 0 => 0 17:21:23.124 SERIAL » [ACK] (0x06) 17:21:23.126 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 0 17:21:23.130 SERIAL » 0x010a00130d0370051e25e94f (12 bytes) 17:21:23.130 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 233 └─[ConfigurationCCGet] parameter #: 30 17:21:23.131 CNTRLR « [Node 012] parameter #14 has value: 0 17:21:23.131 CNTRLR » [Node 012] querying parameter #17 value... 17:21:23.136 SERIAL « [ACK] (0x06) 17:21:23.139 SERIAL « 0x0104011301e8 (6 bytes) 17:21:23.140 SERIAL » [ACK] (0x06) 17:21:23.142 DRIVER « [RES] [SendData] was sent: true 17:21:23.185 SERIAL « 0x01070013e900000507 (9 bytes) 17:21:23.186 SERIAL » [ACK] (0x06) 17:21:23.186 DRIVER « [REQ] [SendData] callback id: 233 transmit status: OK 17:21:23.238 SERIAL « 0x010b0004000d0570061e010293 (13 bytes) 17:21:23.245 CNTRLR [Node 013] [~] [Configuration] 30: 2 => 2 17:21:23.246 SERIAL » [ACK] (0x06) 17:21:23.247 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 2 17:21:23.252 SERIAL » 0x010a00130e0370051e25ea4f (12 bytes) 17:21:23.252 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 234 └─[ConfigurationCCGet] parameter #: 30 17:21:23.253 CNTRLR « [Node 013] parameter #30 has value: 2 17:21:23.253 CNTRLR » [Node 013] querying parameter #31 value... 17:21:23.257 SERIAL « [ACK] (0x06) 17:21:23.263 SERIAL « 0x0104011301e8 (6 bytes) 17:21:23.264 SERIAL » [ACK] (0x06) 17:21:23.265 DRIVER « [RES] [SendData] was sent: true 17:21:23.326 SERIAL « 0x01070013ea00000706 (9 bytes) 17:21:23.326 SERIAL » [ACK] (0x06) 17:21:23.327 DRIVER « [REQ] [SendData] callback id: 234 transmit status: OK 17:21:23.337 SERIAL « 0x010b0004000e0570061e010290 (13 bytes) 17:21:23.344 CNTRLR [Node 014] [~] [Configuration] 30: 2 => 2 17:21:23.346 SERIAL » [ACK] (0x06) 17:21:23.347 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 2 17:21:23.351 SERIAL » 0x010a00130f0370053125eb60 (12 bytes) 17:21:23.352 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 235 └─[ConfigurationCCGet] parameter #: 49 17:21:23.352 CNTRLR « [Node 014] parameter #30 has value: 2 17:21:23.352 CNTRLR » [Node 014] querying parameter #31 value... 17:21:23.361 SERIAL « [ACK] (0x06) 17:21:23.363 SERIAL « 0x0104011301e8 (6 bytes) 17:21:23.363 SERIAL » [ACK] (0x06) 17:21:23.366 DRIVER « [RES] [SendData] was sent: true 17:21:23.377 SERIAL « 0x01070013eb00000202 (9 bytes) 17:21:23.377 SERIAL » [ACK] (0x06) 17:21:23.378 DRIVER « [REQ] [SendData] callback id: 235 transmit status: OK 17:21:23.388 SERIAL « 0x010b0004000f057006310100bc (13 bytes) 17:21:23.395 CNTRLR [Node 015] [~] [Configuration] 49: 0 => 0 17:21:23.396 SERIAL » [ACK] (0x06) 17:21:23.397 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 49 value size: 1 value: 0 17:21:23.402 SERIAL » 0x010a0013100370050e25ec47 (12 bytes) 17:21:23.402 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 236 └─[ConfigurationCCGet] parameter #: 14 17:21:23.403 CNTRLR « [Node 015] parameter #49 has value: 0 17:21:23.403 CNTRLR » [Node 015] querying parameter #50 value... 17:21:23.408 SERIAL « [ACK] (0x06) 17:21:23.411 SERIAL « 0x0104011301e8 (6 bytes) 17:21:23.412 SERIAL » [ACK] (0x06) 17:21:23.413 DRIVER « [RES] [SendData] was sent: true 17:21:23.449 SERIAL « 0x01070013ec00000403 (9 bytes) 17:21:23.450 SERIAL » [ACK] (0x06) 17:21:23.450 DRIVER « [REQ] [SendData] callback id: 236 transmit status: OK 17:21:23.497 SERIAL « 0x010b000400100570060e01009c (13 bytes) 17:21:23.507 CNTRLR [Node 016] [~] [Configuration] 14: 0 => 0 17:21:23.508 SERIAL » [ACK] (0x06) 17:21:23.509 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 0 17:21:23.522 SERIAL » 0x010a0013090370052725ed76 (12 bytes) 17:21:23.523 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 237 └─[ConfigurationCCGet] parameter #: 39 17:21:23.524 CNTRLR « [Node 016] parameter #14 has value: 0 17:21:23.524 CNTRLR » [Node 016] querying parameter #17 value... 17:21:23.530 SERIAL « [ACK] (0x06) 17:21:23.533 SERIAL « 0x0104011301e8 (6 bytes) 17:21:23.535 SERIAL » [ACK] (0x06) 17:21:23.536 DRIVER « [RES] [SendData] was sent: true 17:21:23.615 SERIAL « 0x01070013ed0000090f (9 bytes) 17:21:23.616 SERIAL » [ACK] (0x06) 17:21:23.616 DRIVER « [REQ] [SendData] callback id: 237 transmit status: OK 17:21:23.669 SERIAL « 0x010c0004000906700627020258f1 (14 bytes) 17:21:23.676 CNTRLR [Node 009] [~] [Configuration] 39: 600 => 600 17:21:23.677 SERIAL » [ACK] (0x06) 17:21:23.678 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 39 value size: 2 value: 600 17:21:23.686 SERIAL » 0x010a00130c0370051125ee46 (12 bytes) 17:21:23.686 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 238 └─[ConfigurationCCGet] parameter #: 17 17:21:23.687 CNTRLR « [Node 009] parameter #39 has value: 600 17:21:23.688 CNTRLR » [Node 009] querying parameter #40 value... 17:21:23.694 SERIAL « [ACK] (0x06) 17:21:23.700 SERIAL « 0x0104011301e8 (6 bytes) 17:21:23.700 SERIAL » [ACK] (0x06) 17:21:23.702 DRIVER « [RES] [SendData] was sent: true 17:21:23.756 SERIAL « 0x01070013ee00000603 (9 bytes) 17:21:23.757 SERIAL » [ACK] (0x06) 17:21:23.757 DRIVER « [REQ] [SendData] callback id: 238 transmit status: OK 17:21:23.766 SERIAL « 0x010b0004000c05700611010a95 (13 bytes) 17:21:23.776 CNTRLR [Node 012] [~] [Configuration] 17: 10 => 10 17:21:23.777 SERIAL » [ACK] (0x06) 17:21:23.779 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 17 value size: 1 value: 10 17:21:23.786 SERIAL » 0x010a00130d0370051f25ef48 (12 bytes) 17:21:23.787 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 239 └─[ConfigurationCCGet] parameter #: 31 17:21:23.787 CNTRLR « [Node 012] parameter #17 has value: 10 17:21:23.788 CNTRLR » [Node 012] querying parameter #18 value... 17:21:23.792 SERIAL « [ACK] (0x06) 17:21:23.796 SERIAL « 0x0104011301e8 (6 bytes) 17:21:23.796 SERIAL » [ACK] (0x06) 17:21:23.798 DRIVER « [RES] [SendData] was sent: true 17:21:23.842 SERIAL « 0x01070013ef00000501 (9 bytes) 17:21:23.842 SERIAL » [ACK] (0x06) 17:21:23.843 DRIVER « [REQ] [SendData] callback id: 239 transmit status: OK 17:21:23.898 SERIAL « 0x010b0004000d0570061f010090 (13 bytes) 17:21:23.908 CNTRLR [Node 013] [~] [Configuration] 31: 0 => 0 17:21:23.909 SERIAL » [ACK] (0x06) 17:21:23.911 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 0 17:21:23.916 SERIAL » 0x010a00130e0370051f25f054 (12 bytes) 17:21:23.917 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 240 └─[ConfigurationCCGet] parameter #: 31 17:21:23.917 CNTRLR « [Node 013] parameter #31 has value: 0 17:21:23.918 CNTRLR » [Node 013] querying parameter #32 value... 17:21:23.924 SERIAL « [ACK] (0x06) 17:21:23.927 SERIAL « 0x0104011301e8 (6 bytes) 17:21:23.933 SERIAL » [ACK] (0x06) 17:21:23.934 DRIVER « [RES] [SendData] was sent: true 17:21:23.988 SERIAL « 0x01070013f00000061d (9 bytes) 17:21:23.989 SERIAL » [ACK] (0x06) 17:21:23.990 DRIVER « [REQ] [SendData] callback id: 240 transmit status: OK 17:21:23.997 SERIAL « 0x010b0004000e0570061f010093 (13 bytes) 17:21:24.005 CNTRLR [Node 014] [~] [Configuration] 31: 0 => 0 17:21:24.006 SERIAL » [ACK] (0x06) 17:21:24.007 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 0 17:21:24.011 SERIAL » 0x010a00130f0370053225f179 (12 bytes) 17:21:24.012 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 241 └─[ConfigurationCCGet] parameter #: 50 17:21:24.012 CNTRLR « [Node 014] parameter #31 has value: 0 17:21:24.012 CNTRLR » [Node 014] querying parameter #32 value... 17:21:24.017 SERIAL « [ACK] (0x06) 17:21:24.021 SERIAL « 0x0104011301e8 (6 bytes) 17:21:24.021 SERIAL » [ACK] (0x06) 17:21:24.025 DRIVER « [RES] [SendData] was sent: true 17:21:24.037 SERIAL « 0x01070013f100000218 (9 bytes) 17:21:24.038 SERIAL » [ACK] (0x06) 17:21:24.038 DRIVER « [REQ] [SendData] callback id: 241 transmit status: OK 17:21:24.048 SERIAL « 0x010c0004000f0670063202012c95 (14 bytes) 17:21:24.055 CNTRLR [Node 015] [~] [Configuration] 50: 300 => 300 17:21:24.056 SERIAL » [ACK] (0x06) 17:21:24.058 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 2 value: 300 17:21:24.068 SERIAL » 0x010a0013100370051125f246 (12 bytes) 17:21:24.069 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 242 └─[ConfigurationCCGet] parameter #: 17 17:21:24.070 CNTRLR « [Node 015] parameter #50 has value: 300 17:21:24.071 CNTRLR » [Node 015] querying parameter #51 value... 17:21:24.081 SERIAL « [ACK] (0x06) 17:21:24.082 SERIAL « 0x0104011301e8 (6 bytes) 17:21:24.083 SERIAL » [ACK] (0x06) 17:21:24.084 DRIVER « [RES] [SendData] was sent: true 17:21:24.116 SERIAL « 0x01070013f20000041d (9 bytes) 17:21:24.116 SERIAL » [ACK] (0x06) 17:21:24.120 DRIVER « [REQ] [SendData] callback id: 242 transmit status: OK 17:21:24.165 SERIAL « 0x010b0004001005700611010a89 (13 bytes) 17:21:24.170 CNTRLR [Node 016] [~] [Configuration] 17: 10 => 10 17:21:24.171 SERIAL » [ACK] (0x06) 17:21:24.172 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 17 value size: 1 value: 10 17:21:24.175 SERIAL » 0x010a0013090370052825f367 (12 bytes) 17:21:24.176 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 243 └─[ConfigurationCCGet] parameter #: 40 17:21:24.176 CNTRLR « [Node 016] parameter #17 has value: 10 17:21:24.176 CNTRLR » [Node 016] querying parameter #18 value... 17:21:24.180 SERIAL « [ACK] (0x06) 17:21:24.185 SERIAL « 0x0104011301e8 (6 bytes) 17:21:24.185 SERIAL » [ACK] (0x06) 17:21:24.186 DRIVER « [RES] [SendData] was sent: true 17:21:24.268 SERIAL « 0x01090004001e032001ff31 (11 bytes) 17:21:24.268 SERIAL » [ACK] (0x06) 17:21:24.269 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:21:24.270 CNTRLR [Node 030] treating BasicCC Set as a report 17:21:24.271 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:21:24.388 SERIAL « 0x01070013f30000140c (9 bytes) 17:21:24.388 SERIAL » [ACK] (0x06) 17:21:24.389 DRIVER « [REQ] [SendData] callback id: 243 transmit status: OK 17:21:24.440 SERIAL « 0x010b00040009057006280103a0 (13 bytes) 17:21:24.446 CNTRLR [Node 009] [~] [Configuration] 40: 3 => 3 17:21:24.447 SERIAL » [ACK] (0x06) 17:21:24.448 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 3 17:21:24.452 SERIAL » 0x010a00130c0370051225f45f (12 bytes) 17:21:24.452 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 244 └─[ConfigurationCCGet] parameter #: 18 17:21:24.453 CNTRLR « [Node 009] parameter #40 has value: 3 17:21:24.453 CNTRLR » [Node 009] querying parameter #41 value... 17:21:24.457 SERIAL « [ACK] (0x06) 17:21:24.461 SERIAL « 0x0104011301e8 (6 bytes) 17:21:24.461 SERIAL » [ACK] (0x06) 17:21:24.463 DRIVER « [RES] [SendData] was sent: true 17:21:24.536 SERIAL « 0x01070013f400000817 (9 bytes) 17:21:24.536 SERIAL » [ACK] (0x06) 17:21:24.537 DRIVER « [REQ] [SendData] callback id: 244 transmit status: OK 17:21:24.546 SERIAL « 0x010b0004000c05700612010a96 (13 bytes) 17:21:24.551 CNTRLR [Node 012] [~] [Configuration] 18: 10 => 10 17:21:24.552 SERIAL » [ACK] (0x06) 17:21:24.553 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 18 value size: 1 value: 10 17:21:24.559 SERIAL » 0x010a00130d0370052025f56d (12 bytes) 17:21:24.560 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 245 └─[ConfigurationCCGet] parameter #: 32 17:21:24.560 CNTRLR « [Node 012] parameter #18 has value: 10 17:21:24.561 CNTRLR » [Node 012] querying parameter #22 value... 17:21:24.564 SERIAL « [ACK] (0x06) 17:21:24.569 SERIAL « 0x0104011301e8 (6 bytes) 17:21:24.569 SERIAL » [ACK] (0x06) 17:21:24.570 DRIVER « [RES] [SendData] was sent: true 17:21:24.615 SERIAL « 0x01070013f50000051b (9 bytes) 17:21:24.615 SERIAL » [ACK] (0x06) 17:21:24.616 DRIVER « [REQ] [SendData] callback id: 245 transmit status: OK 17:21:24.667 SERIAL « 0x010b0004000d057006200101ae (13 bytes) 17:21:24.672 CNTRLR [Node 013] [~] [Configuration] 32: 1 => 1 17:21:24.673 SERIAL » [ACK] (0x06) 17:21:24.674 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 1 value: 1 17:21:24.677 SERIAL » 0x010a00130e0370052025f66d (12 bytes) 17:21:24.677 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 246 └─[ConfigurationCCGet] parameter #: 32 17:21:24.678 CNTRLR « [Node 013] parameter #32 has value: 1 17:21:24.678 CNTRLR » [Node 013] querying parameter #33 value... 17:21:24.682 SERIAL « [ACK] (0x06) 17:21:24.686 SERIAL « 0x0104011301e8 (6 bytes) 17:21:24.687 SERIAL » [ACK] (0x06) 17:21:24.687 DRIVER « [RES] [SendData] was sent: true 17:21:24.755 SERIAL « 0x01070013f60000071a (9 bytes) 17:21:24.756 SERIAL » [ACK] (0x06) 17:21:24.757 DRIVER « [REQ] [SendData] callback id: 246 transmit status: OK 17:21:24.766 SERIAL « 0x010b0004000e057006200101ad (13 bytes) 17:21:24.771 CNTRLR [Node 014] [~] [Configuration] 32: 1 => 1 17:21:24.772 SERIAL » [ACK] (0x06) 17:21:24.773 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 1 value: 1 17:21:24.776 SERIAL » 0x010a00130f0370053325f77e (12 bytes) 17:21:24.776 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 247 └─[ConfigurationCCGet] parameter #: 51 17:21:24.777 CNTRLR « [Node 014] parameter #32 has value: 1 17:21:24.777 CNTRLR » [Node 014] querying parameter #33 value... 17:21:24.780 SERIAL « [ACK] (0x06) 17:21:24.785 SERIAL « 0x0104011301e8 (6 bytes) 17:21:24.786 SERIAL » [ACK] (0x06) 17:21:24.787 DRIVER « [RES] [SendData] was sent: true 17:21:24.802 SERIAL « 0x01070013f70000021e (9 bytes) 17:21:24.803 SERIAL » [ACK] (0x06) 17:21:24.804 DRIVER « [REQ] [SendData] callback id: 247 transmit status: OK 17:21:24.813 SERIAL « 0x010c0004000f067006330201f44c (14 bytes) 17:21:24.823 CNTRLR [Node 015] [~] [Configuration] 51: 500 => 500 17:21:24.824 SERIAL » [ACK] (0x06) 17:21:24.826 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 51 value size: 2 value: 500 17:21:24.832 SERIAL » 0x010a0013100370051225f84f (12 bytes) 17:21:24.832 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 248 └─[ConfigurationCCGet] parameter #: 18 17:21:24.833 CNTRLR « [Node 015] parameter #51 has value: 500 17:21:24.833 CNTRLR » [Node 015] querying parameter #52 value... 17:21:24.839 SERIAL « [ACK] (0x06) 17:21:24.842 SERIAL « 0x0104011301e8 (6 bytes) 17:21:24.843 SERIAL » [ACK] (0x06) 17:21:24.844 DRIVER « [RES] [SendData] was sent: true 17:21:24.879 SERIAL « 0x01070013f800000417 (9 bytes) 17:21:24.880 SERIAL » [ACK] (0x06) 17:21:24.881 DRIVER « [REQ] [SendData] callback id: 248 transmit status: OK 17:21:24.927 SERIAL « 0x010b0004001005700612010a8a (13 bytes) 17:21:24.933 CNTRLR [Node 016] [~] [Configuration] 18: 10 => 10 17:21:24.934 SERIAL » [ACK] (0x06) 17:21:24.935 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 18 value size: 1 value: 10 17:21:24.939 SERIAL » 0x010a0013090370052925f96c (12 bytes) 17:21:24.940 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 249 └─[ConfigurationCCGet] parameter #: 41 17:21:24.941 CNTRLR « [Node 016] parameter #18 has value: 10 17:21:24.941 CNTRLR » [Node 016] querying parameter #22 value... 17:21:24.945 SERIAL « [ACK] (0x06) 17:21:24.948 SERIAL « 0x0104011301e8 (6 bytes) 17:21:24.949 SERIAL » [ACK] (0x06) 17:21:24.950 DRIVER « [RES] [SendData] was sent: true 17:21:25.045 SERIAL « 0x01070013f900000a18 (9 bytes) 17:21:25.045 SERIAL » [ACK] (0x06) 17:21:25.046 DRIVER « [REQ] [SendData] callback id: 249 transmit status: OK 17:21:25.096 SERIAL « 0x010b00040009057006290102a0 (13 bytes) 17:21:25.101 CNTRLR [Node 009] [~] [Configuration] 41: 2 => 2 17:21:25.102 SERIAL » [ACK] (0x06) 17:21:25.103 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 41 value size: 1 value: 2 17:21:25.111 SERIAL » 0x010a00130c0370051625fa55 (12 bytes) 17:21:25.112 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 250 └─[ConfigurationCCGet] parameter #: 22 17:21:25.112 CNTRLR « [Node 009] parameter #41 has value: 2 17:21:25.112 CNTRLR » [Node 009] querying parameter #42 value... 17:21:25.116 SERIAL « [ACK] (0x06) 17:21:25.120 SERIAL « 0x0104011301e8 (6 bytes) 17:21:25.121 SERIAL » [ACK] (0x06) 17:21:25.122 DRIVER « [RES] [SendData] was sent: true 17:21:25.185 SERIAL « 0x01070013fa00000716 (9 bytes) 17:21:25.186 SERIAL » [ACK] (0x06) 17:21:25.186 DRIVER « [REQ] [SendData] callback id: 250 transmit status: OK 17:21:25.195 SERIAL « 0x010c0004000c067006160200f06f (14 bytes) 17:21:25.200 CNTRLR [Node 012] [~] [Configuration] 22: 240 => 240 17:21:25.201 SERIAL » [ACK] (0x06) 17:21:25.201 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 240 17:21:25.204 SERIAL » 0x010a00130d0370052125fb62 (12 bytes) 17:21:25.205 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 251 └─[ConfigurationCCGet] parameter #: 33 17:21:25.205 CNTRLR « [Node 012] parameter #22 has value: 240 17:21:25.205 CNTRLR » [Node 012] querying parameter #29 value... 17:21:25.209 SERIAL « [ACK] (0x06) 17:21:25.213 SERIAL « 0x0104011301e8 (6 bytes) 17:21:25.213 SERIAL » [ACK] (0x06) 17:21:25.214 DRIVER « [RES] [SendData] was sent: true 17:21:25.259 SERIAL « 0x01070013fb00000616 (9 bytes) 17:21:25.260 SERIAL » [ACK] (0x06) 17:21:25.260 DRIVER « [REQ] [SendData] callback id: 251 transmit status: OK 17:21:25.311 SERIAL « 0x010b0004000d057006210101af (13 bytes) 17:21:25.317 CNTRLR [Node 013] [~] [Configuration] 33: 1 => 1 17:21:25.318 SERIAL » [ACK] (0x06) 17:21:25.318 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 1 value: 1 17:21:25.322 SERIAL » 0x010a00130e0370052125fc66 (12 bytes) 17:21:25.322 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 252 └─[ConfigurationCCGet] parameter #: 33 17:21:25.323 CNTRLR « [Node 013] parameter #33 has value: 1 17:21:25.323 CNTRLR » [Node 013] querying parameter #35 value... 17:21:25.326 SERIAL « [ACK] (0x06) 17:21:25.330 SERIAL « 0x0104011301e8 (6 bytes) 17:21:25.331 SERIAL » [ACK] (0x06) 17:21:25.331 DRIVER « [RES] [SendData] was sent: true 17:21:25.405 SERIAL « 0x01070013fc0000081f (9 bytes) 17:21:25.406 SERIAL » [ACK] (0x06) 17:21:25.406 DRIVER « [REQ] [SendData] callback id: 252 transmit status: OK 17:21:25.416 SERIAL « 0x010b0004000e057006210101ac (13 bytes) 17:21:25.421 CNTRLR [Node 014] [~] [Configuration] 33: 1 => 1 17:21:25.422 SERIAL » [ACK] (0x06) 17:21:25.423 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 1 value: 1 17:21:25.426 SERIAL » 0x010a00130f0370053425fd73 (12 bytes) 17:21:25.426 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 253 └─[ConfigurationCCGet] parameter #: 52 17:21:25.427 CNTRLR « [Node 014] parameter #33 has value: 1 17:21:25.427 CNTRLR » [Node 014] querying parameter #35 value... 17:21:25.430 SERIAL « [ACK] (0x06) 17:21:25.435 SERIAL « 0x0104011301e8 (6 bytes) 17:21:25.435 SERIAL » [ACK] (0x06) 17:21:25.436 DRIVER « [RES] [SendData] was sent: true 17:21:25.452 SERIAL « 0x01070013fd00000214 (9 bytes) 17:21:25.452 SERIAL » [ACK] (0x06) 17:21:25.453 DRIVER « [REQ] [SendData] callback id: 253 transmit status: OK 17:21:25.462 SERIAL « 0x010b0004000f057006340106bf (13 bytes) 17:21:25.468 CNTRLR [Node 015] [~] [Configuration] 52: 6 => 6 17:21:25.468 SERIAL » [ACK] (0x06) 17:21:25.469 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 52 value size: 1 value: 6 17:21:25.474 SERIAL » 0x010a0013100370051625fe4d (12 bytes) 17:21:25.475 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 254 └─[ConfigurationCCGet] parameter #: 22 17:21:25.475 CNTRLR « [Node 015] parameter #52 has value: 6 17:21:25.476 CNTRLR » [Node 015] querying parameter #60 value... 17:21:25.478 SERIAL « [ACK] (0x06) 17:21:25.483 SERIAL « 0x0104011301e8 (6 bytes) 17:21:25.484 SERIAL » [ACK] (0x06) 17:21:25.485 DRIVER « [RES] [SendData] was sent: true 17:21:25.521 SERIAL « 0x01070013fe00000510 (9 bytes) 17:21:25.522 SERIAL » [ACK] (0x06) 17:21:25.522 DRIVER « [REQ] [SendData] callback id: 254 transmit status: OK 17:21:25.570 SERIAL « 0x010c00040010067006160200f073 (14 bytes) 17:21:25.575 CNTRLR [Node 016] [~] [Configuration] 22: 240 => 240 17:21:25.576 SERIAL » [ACK] (0x06) 17:21:25.577 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 240 17:21:25.580 SERIAL » 0x010a0013090370052a25ff69 (12 bytes) 17:21:25.581 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 255 └─[ConfigurationCCGet] parameter #: 42 17:21:25.581 CNTRLR « [Node 016] parameter #22 has value: 240 17:21:25.581 CNTRLR » [Node 016] querying parameter #29 value... 17:21:25.587 SERIAL « [ACK] (0x06) 17:21:25.590 SERIAL « 0x0104011301e8 (6 bytes) 17:21:25.590 SERIAL » [ACK] (0x06) 17:21:25.591 DRIVER « [RES] [SendData] was sent: true 17:21:25.685 SERIAL « 0x01070013ff00000a1e (9 bytes) 17:21:25.685 SERIAL » [ACK] (0x06) 17:21:25.686 DRIVER « [REQ] [SendData] callback id: 255 transmit status: OK 17:21:25.736 SERIAL « 0x010b000400090570062a0103a2 (13 bytes) 17:21:25.742 CNTRLR [Node 009] [~] [Configuration] 42: 3 => 3 17:21:25.743 SERIAL » [ACK] (0x06) 17:21:25.744 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 3 17:21:25.748 SERIAL » 0x010a00130c0370051d2501a5 (12 bytes) 17:21:25.748 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 1 └─[ConfigurationCCGet] parameter #: 29 17:21:25.749 CNTRLR « [Node 009] parameter #42 has value: 3 17:21:25.749 CNTRLR » [Node 009] querying parameter #43 value... 17:21:25.757 SERIAL « [ACK] (0x06) 17:21:25.759 SERIAL « 0x0104011301e8 (6 bytes) 17:21:25.759 SERIAL » [ACK] (0x06) 17:21:25.760 DRIVER « [RES] [SendData] was sent: true 17:21:25.825 SERIAL « 0x0107001301000007ed (9 bytes) 17:21:25.826 SERIAL » [ACK] (0x06) 17:21:25.826 DRIVER « [REQ] [SendData] callback id: 1 transmit status: OK 17:21:25.836 SERIAL « 0x010b0004000c0570061d010093 (13 bytes) 17:21:25.841 CNTRLR [Node 012] [~] [Configuration] 29: 0 => 0 17:21:25.842 SERIAL » [ACK] (0x06) 17:21:25.843 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 29 value size: 1 value: 0 17:21:25.846 SERIAL » 0x010a00130d03700523250299 (12 bytes) 17:21:25.846 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 2 └─[ConfigurationCCGet] parameter #: 35 17:21:25.847 CNTRLR « [Node 012] parameter #29 has value: 0 17:21:25.847 CNTRLR » [Node 012] querying parameter #30 value... 17:21:25.850 SERIAL « [ACK] (0x06) 17:21:25.854 SERIAL « 0x0104011301e8 (6 bytes) 17:21:25.855 SERIAL » [ACK] (0x06) 17:21:25.855 DRIVER « [RES] [SendData] was sent: true 17:21:25.901 SERIAL « 0x0107001302000005ec (9 bytes) 17:21:25.902 SERIAL » [ACK] (0x06) 17:21:25.902 DRIVER « [REQ] [SendData] callback id: 2 transmit status: OK 17:21:25.953 SERIAL « 0x010b0004000d057006230101ad (13 bytes) 17:21:25.958 CNTRLR [Node 013] [~] [Configuration] 35: 1 => 1 17:21:25.959 SERIAL » [ACK] (0x06) 17:21:25.960 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 1 17:21:25.963 SERIAL » 0x010a00130e0370052325039b (12 bytes) 17:21:25.964 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 3 └─[ConfigurationCCGet] parameter #: 35 17:21:25.964 CNTRLR « [Node 013] parameter #35 has value: 1 17:21:25.964 CNTRLR » [Node 013] querying parameter #40 value... 17:21:25.972 SERIAL « [ACK] (0x06) 17:21:25.974 SERIAL « 0x0104011301e8 (6 bytes) 17:21:25.974 SERIAL » [ACK] (0x06) 17:21:25.976 DRIVER « [RES] [SendData] was sent: true 17:21:26.046 SERIAL « 0x0107001303000008e0 (9 bytes) 17:21:26.046 SERIAL » [ACK] (0x06) 17:21:26.047 DRIVER « [REQ] [SendData] callback id: 3 transmit status: OK 17:21:26.056 SERIAL « 0x010b0004000e057006230101ae (13 bytes) 17:21:26.061 CNTRLR [Node 014] [~] [Configuration] 35: 1 => 1 17:21:26.062 SERIAL » [ACK] (0x06) 17:21:26.063 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 1 17:21:26.066 SERIAL » 0x010a00130f0370053c250482 (12 bytes) 17:21:26.067 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 4 └─[ConfigurationCCGet] parameter #: 60 17:21:26.067 CNTRLR « [Node 014] parameter #35 has value: 1 17:21:26.067 CNTRLR » [Node 014] querying parameter #40 value... 17:21:26.070 SERIAL « [ACK] (0x06) 17:21:26.075 SERIAL « 0x0104011301e8 (6 bytes) 17:21:26.076 SERIAL » [ACK] (0x06) 17:21:26.077 DRIVER « [RES] [SendData] was sent: true 17:21:26.092 SERIAL « 0x0107001304000002ed (9 bytes) 17:21:26.092 SERIAL » [ACK] (0x06) 17:21:26.093 DRIVER « [REQ] [SendData] callback id: 4 transmit status: OK 17:21:26.103 SERIAL « 0x010c0004000f0670063c0261a87f (14 bytes) 17:21:26.108 CNTRLR [Node 015] [~] [Configuration] 60: 25000 => 25000 17:21:26.109 SERIAL » [ACK] (0x06) 17:21:26.109 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 2 value: 25000 17:21:26.112 SERIAL » 0x010a0013100370051d2505bd (12 bytes) 17:21:26.113 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 5 └─[ConfigurationCCGet] parameter #: 29 17:21:26.113 CNTRLR « [Node 015] parameter #60 has value: 25000 17:21:26.114 CNTRLR » [Node 015] querying parameter #61 value... 17:21:26.121 SERIAL « [ACK] (0x06) 17:21:26.124 SERIAL « 0x0104011301e8 (6 bytes) 17:21:26.125 SERIAL » [ACK] (0x06) 17:21:26.126 DRIVER « [RES] [SendData] was sent: true 17:21:26.159 SERIAL « 0x0107001305000005eb (9 bytes) 17:21:26.160 SERIAL » [ACK] (0x06) 17:21:26.160 DRIVER « [REQ] [SendData] callback id: 5 transmit status: OK 17:21:26.207 SERIAL « 0x010b000400100570061d01008f (13 bytes) 17:21:26.212 CNTRLR [Node 016] [~] [Configuration] 29: 0 => 0 17:21:26.213 SERIAL » [ACK] (0x06) 17:21:26.214 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 29 value size: 1 value: 0 17:21:26.217 SERIAL » 0x010a0013090370052b250691 (12 bytes) 17:21:26.217 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 6 └─[ConfigurationCCGet] parameter #: 43 17:21:26.217 CNTRLR « [Node 016] parameter #29 has value: 0 17:21:26.218 CNTRLR » [Node 016] querying parameter #30 value... 17:21:26.247 SERIAL « [ACK] (0x06) 17:21:26.261 SERIAL « 0x0104011301e8 (6 bytes) 17:21:26.262 SERIAL » [ACK] (0x06) 17:21:26.263 DRIVER « [RES] [SendData] was sent: true 17:21:26.325 SERIAL « 0x010700130600000ae7 (9 bytes) 17:21:26.325 SERIAL » [ACK] (0x06) 17:21:26.326 DRIVER « [REQ] [SendData] callback id: 6 transmit status: OK 17:21:26.376 SERIAL « 0x010b000400090570062b0101a1 (13 bytes) 17:21:26.382 CNTRLR [Node 009] [~] [Configuration] 43: 1 => 1 17:21:26.397 SERIAL » [ACK] (0x06) 17:21:26.398 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 1 17:21:26.403 SERIAL » 0x010a00130c0370051e2507a0 (12 bytes) 17:21:26.404 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 7 └─[ConfigurationCCGet] parameter #: 30 17:21:26.404 CNTRLR « [Node 009] parameter #43 has value: 1 17:21:26.405 CNTRLR [Node 009] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:21:26.450 SERIAL « [ACK] (0x06) 17:21:26.457 SERIAL « 0x0104011301e8 (6 bytes) 17:21:26.458 SERIAL » [ACK] (0x06) 17:21:26.461 DRIVER « [RES] [SendData] was sent: true 17:21:26.463 CNTRLR [Node 009] MultiChannelAssociationCC: doing a partial interview... 17:21:26.463 CNTRLR » [Node 009] querying multi channel association group #1... 17:21:26.467 SERIAL « 0x0107001307000003ef (9 bytes) 17:21:26.468 SERIAL » [ACK] (0x06) 17:21:26.469 DRIVER « [REQ] [SendData] callback id: 7 transmit status: OK 17:21:26.473 SERIAL « 0x010b0004000c0570061e010292 (13 bytes) 17:21:26.480 CNTRLR [Node 012] [~] [Configuration] 30: 2 => 2 17:21:26.481 SERIAL » [ACK] (0x06) 17:21:26.482 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 2 17:21:26.487 SERIAL » 0x010a001309038e020125084c (12 bytes) 17:21:26.488 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 8 └─[MultiChannelAssociationCCGet] group id: 1 17:21:26.488 CNTRLR « [Node 012] parameter #30 has value: 2 17:21:26.489 CNTRLR » [Node 012] querying parameter #31 value... 17:21:26.493 SERIAL « [ACK] (0x06) 17:21:26.498 SERIAL « 0x0104011301e8 (6 bytes) 17:21:26.499 SERIAL » [ACK] (0x06) 17:21:26.501 DRIVER « [RES] [SendData] was sent: true 17:21:26.543 SERIAL « 0x0107001308000005e6 (9 bytes) 17:21:26.543 SERIAL » [ACK] (0x06) 17:21:26.544 DRIVER « [REQ] [SendData] callback id: 8 transmit status: OK 17:21:26.594 SERIAL « 0x010b00040009058e0301050075 (13 bytes) 17:21:26.595 SERIAL » [ACK] (0x06) 17:21:26.597 CNTRLR [Node 009] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 17:21:26.598 CNTRLR [Node 009] [~] [Multi Channel Association] nodeIds[1]: => 17:21:26.599 CNTRLR [Node 009] [~] [Multi Channel Association] endpoints[1]: => 17:21:26.601 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: endpoints: 17:21:26.604 SERIAL » 0x010a00130d03700528250999 (12 bytes) 17:21:26.604 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 9 └─[ConfigurationCCGet] parameter #: 40 17:21:26.605 CNTRLR « [Node 009] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 17:21:26.605 CNTRLR » [Node 009] querying multi channel association group #2... 17:21:26.608 SERIAL « [ACK] (0x06) 17:21:26.616 SERIAL « 0x0104011301e8 (6 bytes) 17:21:26.616 SERIAL » [ACK] (0x06) 17:21:26.617 DRIVER « [RES] [SendData] was sent: true 17:21:26.715 SERIAL « 0x010700130900000be9 (9 bytes) 17:21:26.715 SERIAL » [ACK] (0x06) 17:21:26.716 DRIVER « [REQ] [SendData] callback id: 9 transmit status: OK 17:21:26.768 SERIAL « 0x010b0004000d05700628010aad (13 bytes) 17:21:26.773 CNTRLR [Node 013] [~] [Configuration] 40: 10 => 10 17:21:26.773 SERIAL » [ACK] (0x06) 17:21:26.774 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 10 17:21:26.795 SERIAL » 0x010a001309038e0202250a4d (12 bytes) 17:21:26.796 DRIVER » [Node 009] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 10 └─[MultiChannelAssociationCCGet] group id: 2 17:21:26.796 CNTRLR « [Node 013] parameter #40 has value: 10 17:21:26.796 CNTRLR » [Node 013] querying parameter #42 value... 17:21:26.804 SERIAL « [ACK] (0x06) 17:21:26.806 SERIAL « 0x0104011301e8 (6 bytes) 17:21:26.807 SERIAL » [ACK] (0x06) 17:21:26.809 DRIVER « [RES] [SendData] was sent: true 17:21:26.885 SERIAL « 0x010700130a000009e8 (9 bytes) 17:21:26.886 SERIAL » [ACK] (0x06) 17:21:26.886 DRIVER « [REQ] [SendData] callback id: 10 transmit status: OK 17:21:26.936 SERIAL « 0x010b00040009058e0302050076 (13 bytes) 17:21:26.937 SERIAL » [ACK] (0x06) 17:21:26.938 CNTRLR [Node 009] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 17:21:26.939 CNTRLR [Node 009] [~] [Multi Channel Association] nodeIds[2]: => 17:21:26.939 CNTRLR [Node 009] [~] [Multi Channel Association] endpoints[2]: => 17:21:26.940 DRIVER « [Node 009] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 17:21:26.944 SERIAL » 0x010a00130e03700528250b98 (12 bytes) 17:21:26.944 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 11 └─[ConfigurationCCGet] parameter #: 40 17:21:26.945 CNTRLR « [Node 009] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 17:21:26.945 CNTRLR [Node 009] [~] [Association] hasLifeline: true => true [internal] 17:21:26.946 CNTRLR [Node 009] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:21:26.972 SERIAL « [ACK] (0x06) 17:21:26.974 SERIAL « 0x0104011301e8 (6 bytes) 17:21:26.974 SERIAL » [ACK] (0x06) 17:21:26.979 DRIVER « [RES] [SendData] was sent: true 17:21:27.025 SERIAL « 0x010700130b000008e8 (9 bytes) 17:21:27.026 SERIAL » [ACK] (0x06) 17:21:27.026 DRIVER « [REQ] [SendData] callback id: 11 transmit status: OK 17:21:27.036 SERIAL « 0x010b0004000e05700628010aae (13 bytes) 17:21:27.041 CNTRLR [Node 014] [~] [Configuration] 40: 10 => 10 17:21:27.042 SERIAL » [ACK] (0x06) 17:21:27.043 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 10 17:21:27.046 SERIAL » 0x010a00130f0370053d250c8b (12 bytes) 17:21:27.046 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 12 └─[ConfigurationCCGet] parameter #: 61 17:21:27.047 CNTRLR « [Node 014] parameter #40 has value: 10 17:21:27.047 CNTRLR » [Node 014] querying parameter #42 value... 17:21:27.050 SERIAL « [ACK] (0x06) 17:21:27.058 SERIAL « 0x0104011301e8 (6 bytes) 17:21:27.058 SERIAL » [ACK] (0x06) 17:21:27.059 DRIVER « [RES] [SendData] was sent: true 17:21:27.072 SERIAL « 0x010700130c000002e5 (9 bytes) 17:21:27.072 SERIAL » [ACK] (0x06) 17:21:27.073 DRIVER « [REQ] [SendData] callback id: 12 transmit status: OK 17:21:27.082 SERIAL « 0x010b0004000f0570063d0101b1 (13 bytes) 17:21:27.087 CNTRLR [Node 015] [~] [Configuration] 61: 1 => 1 17:21:27.088 SERIAL » [ACK] (0x06) 17:21:27.089 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 61 value size: 1 value: 1 17:21:27.092 SERIAL » 0x010a0013100370051e250db6 (12 bytes) 17:21:27.092 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 13 └─[ConfigurationCCGet] parameter #: 30 17:21:27.093 CNTRLR « [Node 015] parameter #61 has value: 1 17:21:27.093 CNTRLR » [Node 015] querying parameter #62 value... 17:21:27.100 SERIAL « [ACK] (0x06) 17:21:27.101 SERIAL « 0x0104011301e8 (6 bytes) 17:21:27.102 SERIAL » [ACK] (0x06) 17:21:27.103 DRIVER « [RES] [SendData] was sent: true 17:21:27.139 SERIAL « 0x010700130d000004e2 (9 bytes) 17:21:27.139 SERIAL » [ACK] (0x06) 17:21:27.139 DRIVER « [REQ] [SendData] callback id: 13 transmit status: OK 17:21:27.187 SERIAL « 0x010b000400100570061e01028e (13 bytes) 17:21:27.192 CNTRLR [Node 016] [~] [Configuration] 30: 2 => 2 17:21:27.193 SERIAL » [ACK] (0x06) 17:21:27.195 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 2 17:21:27.199 SERIAL » 0x010a00130c0370051f250ea8 (12 bytes) 17:21:27.200 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 14 └─[ConfigurationCCGet] parameter #: 31 17:21:27.200 CNTRLR « [Node 016] parameter #30 has value: 2 17:21:27.201 CNTRLR » [Node 016] querying parameter #31 value... 17:21:27.205 SERIAL « [ACK] (0x06) 17:21:27.208 SERIAL « 0x0104011301e8 (6 bytes) 17:21:27.209 SERIAL » [ACK] (0x06) 17:21:27.210 DRIVER « [RES] [SendData] was sent: true 17:21:27.276 SERIAL « 0x010700130e000007e2 (9 bytes) 17:21:27.277 SERIAL » [ACK] (0x06) 17:21:27.278 DRIVER « [REQ] [SendData] callback id: 14 transmit status: OK 17:21:27.286 SERIAL « 0x010b0004000c0570061f010091 (13 bytes) 17:21:27.296 CNTRLR [Node 012] [~] [Configuration] 31: 0 => 0 17:21:27.297 SERIAL » [ACK] (0x06) 17:21:27.308 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 0 17:21:27.314 SERIAL » 0x010a00130d0370052a250f9d (12 bytes) 17:21:27.314 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 15 └─[ConfigurationCCGet] parameter #: 42 17:21:27.315 CNTRLR « [Node 012] parameter #31 has value: 0 17:21:27.316 CNTRLR » [Node 012] querying parameter #32 value... 17:21:27.322 SERIAL « [ACK] (0x06) 17:21:27.325 SERIAL « 0x0104011301e8 (6 bytes) 17:21:27.328 SERIAL » [ACK] (0x06) 17:21:27.330 DRIVER « [RES] [SendData] was sent: true 17:21:27.369 SERIAL « 0x010700130f000005e1 (9 bytes) 17:21:27.369 SERIAL » [ACK] (0x06) 17:21:27.370 DRIVER « [REQ] [SendData] callback id: 15 transmit status: OK 17:21:27.422 SERIAL « 0x010c0004000d0670062a020e10bc (14 bytes) 17:21:27.431 CNTRLR [Node 013] [~] [Configuration] 42: 3600 => 3600 17:21:27.432 SERIAL » [ACK] (0x06) 17:21:27.433 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 3600 17:21:27.439 SERIAL » 0x010a00130e0370052a251081 (12 bytes) 17:21:27.440 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[ConfigurationCCGet] parameter #: 42 17:21:27.441 CNTRLR « [Node 013] parameter #42 has value: 3600 17:21:27.441 CNTRLR » [Node 013] querying parameter #43 value... 17:21:27.447 SERIAL « [ACK] (0x06) 17:21:27.450 SERIAL « 0x0104011301e8 (6 bytes) 17:21:27.451 SERIAL » [ACK] (0x06) 17:21:27.453 DRIVER « [RES] [SendData] was sent: true 17:21:27.516 SERIAL « 0x0107001310000007fc (9 bytes) 17:21:27.517 SERIAL » [ACK] (0x06) 17:21:27.518 DRIVER « [REQ] [SendData] callback id: 16 transmit status: OK 17:21:27.527 SERIAL « 0x010c0004000e0670062a020e10bf (14 bytes) 17:21:27.532 CNTRLR [Node 014] [~] [Configuration] 42: 3600 => 3600 17:21:27.533 SERIAL » [ACK] (0x06) 17:21:27.533 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 3600 17:21:27.537 SERIAL » 0x010a00130f0370053e251195 (12 bytes) 17:21:27.537 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 17 └─[ConfigurationCCGet] parameter #: 62 17:21:27.537 CNTRLR « [Node 014] parameter #42 has value: 3600 17:21:27.538 CNTRLR » [Node 014] querying parameter #43 value... 17:21:27.541 SERIAL « [ACK] (0x06) 17:21:27.546 SERIAL « 0x0104011301e8 (6 bytes) 17:21:27.546 SERIAL » [ACK] (0x06) 17:21:27.547 DRIVER « [RES] [SendData] was sent: true 17:21:27.563 SERIAL « 0x0107001311000002f8 (9 bytes) 17:21:27.563 SERIAL » [ACK] (0x06) 17:21:27.564 DRIVER « [REQ] [SendData] callback id: 17 transmit status: OK 17:21:27.573 SERIAL « 0x010b0004000f0570063e0108bb (13 bytes) 17:21:27.581 CNTRLR [Node 015] [~] [Configuration] 62: 8 => 8 17:21:27.583 SERIAL » [ACK] (0x06) 17:21:27.583 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 62 value size: 1 value: 8 17:21:27.587 SERIAL » 0x010a0013100370051f2512a8 (12 bytes) 17:21:27.587 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 18 └─[ConfigurationCCGet] parameter #: 31 17:21:27.587 CNTRLR « [Node 015] parameter #62 has value: 8 17:21:27.588 CNTRLR » [Node 015] querying parameter #63 value... 17:21:27.595 SERIAL « [ACK] (0x06) 17:21:27.597 SERIAL « 0x0104011301e8 (6 bytes) 17:21:27.597 SERIAL » [ACK] (0x06) 17:21:27.598 DRIVER « [RES] [SendData] was sent: true 17:21:27.634 SERIAL « 0x0107001312000004fd (9 bytes) 17:21:27.634 SERIAL » [ACK] (0x06) 17:21:27.635 DRIVER « [REQ] [SendData] callback id: 18 transmit status: OK 17:21:27.681 SERIAL « 0x010b000400100570061f01008d (13 bytes) 17:21:27.686 CNTRLR [Node 016] [~] [Configuration] 31: 0 => 0 17:21:27.687 SERIAL » [ACK] (0x06) 17:21:27.688 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 0 17:21:27.691 SERIAL » 0x010a00130c0370052025138a (12 bytes) 17:21:27.691 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 19 └─[ConfigurationCCGet] parameter #: 32 17:21:27.692 CNTRLR « [Node 016] parameter #31 has value: 0 17:21:27.692 CNTRLR » [Node 016] querying parameter #32 value... 17:21:27.696 SERIAL « [ACK] (0x06) 17:21:27.700 SERIAL « 0x0104011301e8 (6 bytes) 17:21:27.700 SERIAL » [ACK] (0x06) 17:21:27.701 DRIVER « [RES] [SendData] was sent: true 17:21:27.775 SERIAL « 0x0107001313000008f0 (9 bytes) 17:21:27.776 SERIAL » [ACK] (0x06) 17:21:27.776 DRIVER « [REQ] [SendData] callback id: 19 transmit status: OK 17:21:27.786 SERIAL « 0x010b0004000c057006200101af (13 bytes) 17:21:27.791 CNTRLR [Node 012] [~] [Configuration] 32: 1 => 1 17:21:27.792 SERIAL » [ACK] (0x06) 17:21:27.793 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 1 value: 1 17:21:27.796 SERIAL » 0x010a00130d0370052b251487 (12 bytes) 17:21:27.796 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 20 └─[ConfigurationCCGet] parameter #: 43 17:21:27.797 CNTRLR « [Node 012] parameter #32 has value: 1 17:21:27.797 CNTRLR » [Node 012] querying parameter #33 value... 17:21:27.800 SERIAL « [ACK] (0x06) 17:21:27.805 SERIAL « 0x0104011301e8 (6 bytes) 17:21:27.805 SERIAL » [ACK] (0x06) 17:21:27.806 DRIVER « [RES] [SendData] was sent: true 17:21:27.851 SERIAL « 0x0107001314000005fa (9 bytes) 17:21:27.851 SERIAL » [ACK] (0x06) 17:21:27.851 DRIVER « [REQ] [SendData] callback id: 20 transmit status: OK 17:21:27.858 CNTRLR [Node 009] Interview stage completed: CommandClasses 17:21:27.858 CNTRLR [Node 009] Interview stage completed: OverwriteConfig 17:21:27.859 CNTRLR » [Node 009] requesting node neighbors... 17:21:27.903 SERIAL « 0x010b0004000d0570062b010aae (13 bytes) 17:21:27.908 CNTRLR [Node 013] [~] [Configuration] 43: 10 => 10 17:21:27.909 SERIAL » [ACK] (0x06) 17:21:27.910 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 10 17:21:27.916 SERIAL » 0x010700800900000071 (9 bytes) 17:21:27.917 DRIVER » [Node 009] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:21:27.917 CNTRLR « [Node 013] parameter #43 has value: 10 17:21:27.918 CNTRLR » [Node 013] querying parameter #44 value... 17:21:27.922 SERIAL « [ACK] (0x06) 17:21:27.924 SERIAL « 0x0120018065ee886b0700000000000000000000000000000000000000000000000 (34 bytes) 031 17:21:27.925 SERIAL » [ACK] (0x06) 17:21:27.926 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 10, 11, 12, 14, 15, 16, 20, 24, 25, 26, 28, 30, 31, 33 , 34, 35 17:21:27.931 SERIAL » 0x010a00130e0370052b251585 (12 bytes) 17:21:27.931 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 21 └─[ConfigurationCCGet] parameter #: 43 17:21:27.932 CNTRLR « [Node 009] node neighbors received: 1, 3, 6, 7, 10, 11, 12, 14, 15, 16, 20, 24, 25, 26, 28, 30, 31, 33, 34, 35 17:21:27.932 CNTRLR [Node 009] Interview stage completed: Neighbors 17:21:27.932 CNTRLR [Node 009] Interview completed 17:21:27.935 SERIAL « [ACK] (0x06) 17:21:27.939 SERIAL « 0x0104011301e8 (6 bytes) 17:21:27.940 SERIAL » [ACK] (0x06) 17:21:27.940 DRIVER « [RES] [SendData] was sent: true 17:21:27.995 SERIAL « 0x0107001315000006f8 (9 bytes) 17:21:27.996 SERIAL » [ACK] (0x06) 17:21:27.996 DRIVER « [REQ] [SendData] callback id: 21 transmit status: OK 17:21:28.006 SERIAL « 0x010b0004000e0570062b010aad (13 bytes) 17:21:28.011 CNTRLR [Node 014] [~] [Configuration] 43: 10 => 10 17:21:28.012 SERIAL » [ACK] (0x06) 17:21:28.013 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 10 17:21:28.016 SERIAL » 0x010a00130f0370053f251693 (12 bytes) 17:21:28.016 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 22 └─[ConfigurationCCGet] parameter #: 63 17:21:28.017 CNTRLR « [Node 014] parameter #43 has value: 10 17:21:28.017 CNTRLR » [Node 014] querying parameter #44 value... 17:21:28.052 SERIAL « [ACK] (0x06) 17:21:28.053 SERIAL « 0x0104011301e8 (6 bytes) 17:21:28.053 SERIAL » [ACK] (0x06) 17:21:28.054 DRIVER « [RES] [SendData] was sent: true 17:21:28.060 SERIAL « 0x0107001316000002ff (9 bytes) 17:21:28.060 SERIAL » [ACK] (0x06) 17:21:28.061 DRIVER « [REQ] [SendData] callback id: 22 transmit status: OK 17:21:28.067 SERIAL « 0x010b0004000f0570063f0101b3 (13 bytes) 17:21:28.075 CNTRLR [Node 015] [~] [Configuration] 63: 1 => 1 17:21:28.076 SERIAL » [ACK] (0x06) 17:21:28.077 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 63 value size: 1 value: 1 17:21:28.081 SERIAL » 0x010a00131003700520251792 (12 bytes) 17:21:28.082 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 23 └─[ConfigurationCCGet] parameter #: 32 17:21:28.082 CNTRLR « [Node 015] parameter #63 has value: 1 17:21:28.082 CNTRLR » [Node 015] querying parameter #70 value... 17:21:28.087 SERIAL « [ACK] (0x06) 17:21:28.092 SERIAL « 0x0104011301e8 (6 bytes) 17:21:28.093 SERIAL » [ACK] (0x06) 17:21:28.093 DRIVER « [RES] [SendData] was sent: true 17:21:28.128 SERIAL « 0x0107001317000004f8 (9 bytes) 17:21:28.128 SERIAL » [ACK] (0x06) 17:21:28.129 DRIVER « [REQ] [SendData] callback id: 23 transmit status: OK 17:21:28.175 SERIAL « 0x010b00040010057006200101b3 (13 bytes) 17:21:28.180 CNTRLR [Node 016] [~] [Configuration] 32: 1 => 1 17:21:28.181 SERIAL » [ACK] (0x06) 17:21:28.182 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 1 value: 1 17:21:28.185 SERIAL » 0x010a00130c03700521251880 (12 bytes) 17:21:28.186 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 24 └─[ConfigurationCCGet] parameter #: 33 17:21:28.186 CNTRLR « [Node 016] parameter #32 has value: 1 17:21:28.186 CNTRLR » [Node 016] querying parameter #33 value... 17:21:28.189 SERIAL « [ACK] (0x06) 17:21:28.197 SERIAL « 0x0104011301e8 (6 bytes) 17:21:28.198 SERIAL » [ACK] (0x06) 17:21:28.199 DRIVER « [RES] [SendData] was sent: true 17:21:28.266 SERIAL « 0x0107001318000007f4 (9 bytes) 17:21:28.266 SERIAL » [ACK] (0x06) 17:21:28.267 DRIVER « [REQ] [SendData] callback id: 24 transmit status: OK 17:21:28.276 SERIAL « 0x010b0004000c057006210101ae (13 bytes) 17:21:28.286 CNTRLR [Node 012] [~] [Configuration] 33: 1 => 1 17:21:28.287 SERIAL » [ACK] (0x06) 17:21:28.289 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 1 value: 1 17:21:28.294 SERIAL » 0x010a00130d0370052c25198d (12 bytes) 17:21:28.295 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 25 └─[ConfigurationCCGet] parameter #: 44 17:21:28.296 CNTRLR « [Node 012] parameter #33 has value: 1 17:21:28.296 CNTRLR » [Node 012] querying parameter #35 value... 17:21:28.311 SERIAL « [ACK] (0x06) 17:21:28.313 SERIAL « 0x0104011301e8 (6 bytes) 17:21:28.314 SERIAL » [ACK] (0x06) 17:21:28.317 DRIVER « [RES] [SendData] was sent: true 17:21:28.350 SERIAL « 0x0107001319000006f4 (9 bytes) 17:21:28.351 SERIAL » [ACK] (0x06) 17:21:28.351 DRIVER « [REQ] [SendData] callback id: 25 transmit status: OK 17:21:28.402 SERIAL « 0x010b0004000d0570062c0100a3 (13 bytes) 17:21:28.409 CNTRLR [Node 013] [~] [Configuration] 44: 0 => 0 17:21:28.410 SERIAL » [ACK] (0x06) 17:21:28.411 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 44 value size: 1 value: 0 17:21:28.416 SERIAL » 0x010a00130e0370052c251a8d (12 bytes) 17:21:28.417 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 26 └─[ConfigurationCCGet] parameter #: 44 17:21:28.417 CNTRLR « [Node 013] parameter #44 has value: 0 17:21:28.418 CNTRLR » [Node 013] querying parameter #50 value... 17:21:28.422 SERIAL « [ACK] (0x06) 17:21:28.432 SERIAL « 0x0104011301e8 (6 bytes) 17:21:28.433 SERIAL » [ACK] (0x06) 17:21:28.434 DRIVER « [RES] [SendData] was sent: true 17:21:28.496 SERIAL « 0x010700131a000007f6 (9 bytes) 17:21:28.496 SERIAL » [ACK] (0x06) 17:21:28.497 DRIVER « [REQ] [SendData] callback id: 26 transmit status: OK 17:21:28.506 SERIAL « 0x010b0004000e0570062c0100a0 (13 bytes) 17:21:28.517 CNTRLR [Node 014] [~] [Configuration] 44: 0 => 0 17:21:28.518 SERIAL » [ACK] (0x06) 17:21:28.519 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 44 value size: 1 value: 0 17:21:28.523 SERIAL » 0x010a00130f03700546251be7 (12 bytes) 17:21:28.524 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 27 └─[ConfigurationCCGet] parameter #: 70 17:21:28.525 CNTRLR « [Node 014] parameter #44 has value: 0 17:21:28.525 CNTRLR » [Node 014] querying parameter #50 value... 17:21:28.529 SERIAL « [ACK] (0x06) 17:21:28.532 SERIAL « 0x0104011301e8 (6 bytes) 17:21:28.533 SERIAL » [ACK] (0x06) 17:21:28.538 DRIVER « [RES] [SendData] was sent: true 17:21:28.550 SERIAL « 0x010700131b000003f3 (9 bytes) 17:21:28.551 SERIAL » [ACK] (0x06) 17:21:28.551 DRIVER « [REQ] [SendData] callback id: 27 transmit status: OK 17:21:28.560 SERIAL « 0x010c0004000f0670064602ffffcc (14 bytes) 17:21:28.568 CNTRLR [Node 015] [~] [Configuration] 70: 65535 => 65535 17:21:28.569 SERIAL » [ACK] (0x06) 17:21:28.570 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 70 value size: 2 value: 65535 17:21:28.576 SERIAL » 0x010a00131003700521251c98 (12 bytes) 17:21:28.577 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 28 └─[ConfigurationCCGet] parameter #: 33 17:21:28.577 CNTRLR « [Node 015] parameter #70 has value: 65535 17:21:28.578 CNTRLR [Node 015] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:21:28.620 SERIAL « [ACK] (0x06) 17:21:28.626 SERIAL « 0x0104011301e8 (6 bytes) 17:21:28.626 SERIAL » [ACK] (0x06) 17:21:28.628 DRIVER « [RES] [SendData] was sent: true 17:21:28.633 CNTRLR [Node 015] MultiChannelAssociationCC: doing a partial interview... 17:21:28.633 CNTRLR » [Node 015] querying multi channel association group #1... 17:21:28.637 SERIAL « 0x010700131c000004f3 (9 bytes) 17:21:28.638 SERIAL » [ACK] (0x06) 17:21:28.640 DRIVER « [REQ] [SendData] callback id: 28 transmit status: OK 17:21:28.671 SERIAL « 0x010b00040010057006210101b2 (13 bytes) 17:21:28.677 CNTRLR [Node 016] [~] [Configuration] 33: 1 => 1 17:21:28.677 SERIAL » [ACK] (0x06) 17:21:28.678 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 1 value: 1 17:21:28.686 SERIAL » 0x010a00130f038e0201251d5f (12 bytes) 17:21:28.686 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 29 └─[MultiChannelAssociationCCGet] group id: 1 17:21:28.687 CNTRLR « [Node 016] parameter #33 has value: 1 17:21:28.687 CNTRLR » [Node 016] querying parameter #35 value... 17:21:28.691 SERIAL « [ACK] (0x06) 17:21:28.695 SERIAL « 0x0104011301e8 (6 bytes) 17:21:28.696 SERIAL » [ACK] (0x06) 17:21:28.697 DRIVER « [RES] [SendData] was sent: true 17:21:28.755 SERIAL « 0x010700131d000006f0 (9 bytes) 17:21:28.756 SERIAL » [ACK] (0x06) 17:21:28.756 DRIVER « [REQ] [SendData] callback id: 29 transmit status: OK 17:21:28.766 SERIAL « 0x010b0004000f058e0301050073 (13 bytes) 17:21:28.766 SERIAL » [ACK] (0x06) 17:21:28.767 CNTRLR [Node 015] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 17:21:28.768 CNTRLR [Node 015] [~] [Multi Channel Association] nodeIds[1]: => 17:21:28.769 CNTRLR [Node 015] [~] [Multi Channel Association] endpoints[1]: => 17:21:28.770 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: endpoints: 17:21:28.773 SERIAL » 0x010a00130c03700523251e84 (12 bytes) 17:21:28.774 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 30 └─[ConfigurationCCGet] parameter #: 35 17:21:28.775 CNTRLR « [Node 015] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 17:21:28.775 CNTRLR » [Node 015] querying multi channel association group #2... 17:21:28.779 SERIAL « [ACK] (0x06) 17:21:28.784 SERIAL « 0x0104011301e8 (6 bytes) 17:21:28.785 SERIAL » [ACK] (0x06) 17:21:28.789 DRIVER « [RES] [SendData] was sent: true 17:21:28.800 SERIAL « 0x010700131e000003f6 (9 bytes) 17:21:28.800 SERIAL » [ACK] (0x06) 17:21:28.800 DRIVER « [REQ] [SendData] callback id: 30 transmit status: OK 17:21:28.811 SERIAL « 0x010b0004000c057006230101ac (13 bytes) 17:21:28.816 CNTRLR [Node 012] [~] [Configuration] 35: 1 => 1 17:21:28.816 SERIAL » [ACK] (0x06) 17:21:28.817 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 1 17:21:28.820 SERIAL » 0x010a00130f038e0202251f5e (12 bytes) 17:21:28.821 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 31 └─[MultiChannelAssociationCCGet] group id: 2 17:21:28.821 CNTRLR « [Node 012] parameter #35 has value: 1 17:21:28.821 CNTRLR » [Node 012] querying parameter #40 value... 17:21:28.824 SERIAL « [ACK] (0x06) 17:21:28.828 SERIAL « 0x0104011301e8 (6 bytes) 17:21:28.829 SERIAL » [ACK] (0x06) 17:21:28.829 DRIVER « [RES] [SendData] was sent: true 17:21:28.846 SERIAL « 0x010700131f000002f6 (9 bytes) 17:21:28.846 SERIAL » [ACK] (0x06) 17:21:28.847 DRIVER « [REQ] [SendData] callback id: 31 transmit status: OK 17:21:28.856 SERIAL « 0x010b0004000f058e0302050070 (13 bytes) 17:21:28.857 SERIAL » [ACK] (0x06) 17:21:28.858 CNTRLR [Node 015] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 17:21:28.858 CNTRLR [Node 015] [~] [Multi Channel Association] nodeIds[2]: => 17:21:28.859 CNTRLR [Node 015] [~] [Multi Channel Association] endpoints[2]: => 17:21:28.860 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 17:21:28.863 SERIAL » 0x010a00130d037005322520aa (12 bytes) 17:21:28.864 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 32 └─[ConfigurationCCGet] parameter #: 50 17:21:28.864 CNTRLR « [Node 015] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 17:21:28.864 CNTRLR » [Node 015] querying additional non-multi-channel association groups... 17:21:28.864 CNTRLR » [Node 015] querying association group #3... 17:21:28.868 SERIAL « [ACK] (0x06) 17:21:28.872 SERIAL « 0x0104011301e8 (6 bytes) 17:21:28.873 SERIAL » [ACK] (0x06) 17:21:28.874 DRIVER « [RES] [SendData] was sent: true 17:21:28.918 SERIAL « 0x0107001320000005ce (9 bytes) 17:21:28.919 SERIAL » [ACK] (0x06) 17:21:28.919 DRIVER « [REQ] [SendData] callback id: 32 transmit status: OK 17:21:28.970 SERIAL « 0x010b0004000d057006320100bd (13 bytes) 17:21:28.975 CNTRLR [Node 013] [~] [Configuration] 50: 0 => 0 17:21:28.976 SERIAL » [ACK] (0x06) 17:21:28.976 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 0 17:21:28.980 SERIAL » 0x010a00130f0385020325216a (12 bytes) 17:21:28.980 DRIVER » [Node 015] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 33 └─[AssociationCCGet] group id: 3 17:21:28.981 CNTRLR « [Node 013] parameter #50 has value: 0 17:21:28.981 CNTRLR [Node 013] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:21:29.008 SERIAL « [ACK] (0x06) 17:21:29.013 SERIAL « 0x0104011301e8 (6 bytes) 17:21:29.013 SERIAL » [ACK] (0x06) 17:21:29.014 DRIVER « [RES] [SendData] was sent: true 17:21:29.018 CNTRLR [Node 013] ProtectionCC: doing a partial interview... 17:21:29.018 CNTRLR » [Node 013] querying protection status... 17:21:29.021 SERIAL « 0x0107001321000003c9 (9 bytes) 17:21:29.022 SERIAL » [ACK] (0x06) 17:21:29.022 DRIVER « [REQ] [SendData] callback id: 33 transmit status: OK 17:21:29.027 SERIAL « 0x010c0004000f068503030100017b (14 bytes) 17:21:29.028 SERIAL » [ACK] (0x06) 17:21:29.029 CNTRLR [Node 015] [~] [Association] maxNodes[3]: 1 => 1 [internal] 17:21:29.029 CNTRLR [Node 015] [~] [Association] nodeIds[3]: 1 => 1 [internal] 17:21:29.029 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 17:21:29.033 SERIAL » 0x010a00130e037005322522ab (12 bytes) 17:21:29.033 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 34 └─[ConfigurationCCGet] parameter #: 50 17:21:29.034 CNTRLR « [Node 015] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 17:21:29.034 CNTRLR [Node 015] [~] [Association] hasLifeline: true => true [internal] 17:21:29.034 CNTRLR [Node 015] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:21:29.034 CNTRLR [Node 015] Interview stage completed: CommandClasses 17:21:29.035 CNTRLR [Node 015] Interview stage completed: OverwriteConfig 17:21:29.035 CNTRLR » [Node 015] requesting node neighbors... 17:21:29.037 SERIAL « [ACK] (0x06) 17:21:29.041 SERIAL « 0x0104011301e8 (6 bytes) 17:21:29.041 SERIAL » [ACK] (0x06) 17:21:29.042 DRIVER « [RES] [SendData] was sent: true 17:21:29.058 SERIAL « 0x0107001322000002cb (9 bytes) 17:21:29.059 SERIAL » [ACK] (0x06) 17:21:29.059 DRIVER « [REQ] [SendData] callback id: 34 transmit status: OK 17:21:29.069 SERIAL « 0x010b0004000e057006320100be (13 bytes) 17:21:29.074 CNTRLR [Node 014] [~] [Configuration] 50: 0 => 0 17:21:29.075 SERIAL » [ACK] (0x06) 17:21:29.076 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 0 17:21:29.079 SERIAL » 0x010700800f00000077 (9 bytes) 17:21:29.079 DRIVER » [Node 015] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:21:29.080 CNTRLR « [Node 014] parameter #50 has value: 0 17:21:29.080 CNTRLR [Node 014] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:21:29.081 CNTRLR [Node 014] ProtectionCC: doing a partial interview... 17:21:29.081 CNTRLR » [Node 014] querying protection status... 17:21:29.085 SERIAL « [ACK] (0x06) 17:21:29.086 SERIAL « 0x0120018065b9fd6b0700000000000000000000000000000000000000000000000 (34 bytes) 013 17:21:29.087 SERIAL » [ACK] (0x06) 17:21:29.088 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 9, 12, 13, 14, 16, 17, 19, 20, 21, 22, 23, 24, 25, 26, 28, 30, 31, 33, 34, 35 17:21:29.093 SERIAL » 0x010a001310037005232523a5 (12 bytes) 17:21:29.093 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 35 └─[ConfigurationCCGet] parameter #: 35 17:21:29.094 CNTRLR « [Node 015] node neighbors received: 1, 3, 6, 7, 9, 12, 13, 14, 16, 17, 19, 2 0, 21, 22, 23, 24, 25, 26, 28, 30, 31, 33, 34, 35 17:21:29.094 CNTRLR [Node 015] Interview stage completed: Neighbors 17:21:29.094 CNTRLR [Node 015] Interview completed 17:21:29.097 SERIAL « [ACK] (0x06) 17:21:29.101 SERIAL « 0x0104011301e8 (6 bytes) 17:21:29.102 SERIAL » [ACK] (0x06) 17:21:29.102 DRIVER « [RES] [SendData] was sent: true 17:21:29.140 SERIAL « 0x0107001323000005cd (9 bytes) 17:21:29.140 SERIAL » [ACK] (0x06) 17:21:29.140 DRIVER « [REQ] [SendData] callback id: 35 transmit status: OK 17:21:29.216 SERIAL « 0x010b00040010057006230101b0 (13 bytes) 17:21:29.221 CNTRLR [Node 016] [~] [Configuration] 35: 1 => 1 17:21:29.222 SERIAL » [ACK] (0x06) 17:21:29.224 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 1 17:21:29.228 SERIAL » 0x010a00130c037005282524b5 (12 bytes) 17:21:29.228 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 36 └─[ConfigurationCCGet] parameter #: 40 17:21:29.229 CNTRLR « [Node 016] parameter #35 has value: 1 17:21:29.229 CNTRLR » [Node 016] querying parameter #40 value... 17:21:29.237 SERIAL « [ACK] (0x06) 17:21:29.239 SERIAL « 0x0104011301e8 (6 bytes) 17:21:29.239 SERIAL » [ACK] (0x06) 17:21:29.242 DRIVER « [RES] [SendData] was sent: true 17:21:29.275 SERIAL « 0x0107001324000004cb (9 bytes) 17:21:29.276 SERIAL » [ACK] (0x06) 17:21:29.276 DRIVER « [REQ] [SendData] callback id: 36 transmit status: OK 17:21:29.286 SERIAL « 0x010b0004000c05700628010aac (13 bytes) 17:21:29.291 CNTRLR [Node 012] [~] [Configuration] 40: 10 => 10 17:21:29.292 SERIAL » [ACK] (0x06) 17:21:29.292 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 10 17:21:29.296 SERIAL » 0x010900130d02750225259d (11 bytes) 17:21:29.296 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 37 └─[ProtectionCCGet] 17:21:29.297 CNTRLR « [Node 012] parameter #40 has value: 10 17:21:29.297 CNTRLR » [Node 012] querying parameter #42 value... 17:21:29.300 SERIAL « [ACK] (0x06) 17:21:29.308 SERIAL « 0x0104011301e8 (6 bytes) 17:21:29.309 SERIAL » [ACK] (0x06) 17:21:29.309 DRIVER « [RES] [SendData] was sent: true 17:21:29.350 SERIAL « 0x0107001325000006c8 (9 bytes) 17:21:29.351 SERIAL » [ACK] (0x06) 17:21:29.351 DRIVER « [REQ] [SendData] callback id: 37 transmit status: OK 17:21:29.401 SERIAL « 0x010a0004000d04750300008e (12 bytes) 17:21:29.403 CNTRLR [Node 013] [~] [Protection] local: 0 => 0 [Endpoint 0] 17:21:29.403 CNTRLR [Node 013] [~] [Protection] rf: 0 => 0 [Endpoint 0] 17:21:29.404 SERIAL » [ACK] (0x06) 17:21:29.406 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 17:21:29.410 SERIAL » 0x010900130e02750225269d (11 bytes) 17:21:29.411 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 38 └─[ProtectionCCGet] 17:21:29.411 CNTRLR « [Node 013] received protection status: local: Unprotected rf Unprotected 17:21:29.412 CNTRLR [Node 013] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 17:21:29.451 SERIAL « [ACK] (0x06) 17:21:29.458 SERIAL « 0x0104011301e8 (6 bytes) 17:21:29.458 SERIAL » [ACK] (0x06) 17:21:29.460 DRIVER « [RES] [SendData] was sent: true 17:21:29.477 CNTRLR [Node 013] FibaroVenetianBlindCC: doing a partial interview... 17:21:29.478 CNTRLR » [Node 013] Requesting venetian blind position and tilt... 17:21:29.495 SERIAL « 0x0107001326000008c5 (9 bytes) 17:21:29.496 SERIAL » [ACK] (0x06) 17:21:29.497 DRIVER « [REQ] [SendData] callback id: 38 transmit status: OK 17:21:29.506 SERIAL « 0x010a0004000e04750300008d (12 bytes) 17:21:29.507 CNTRLR [Node 014] [~] [Protection] local: 0 => 0 [Endpoint 0] 17:21:29.507 CNTRLR [Node 014] [~] [Protection] rf: 0 => 0 [Endpoint 0] 17:21:29.508 SERIAL » [ACK] (0x06) 17:21:29.509 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 17:21:29.529 SERIAL » 0x010c00130d0591010f2602252751 (14 bytes) 17:21:29.529 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[FibaroVenetianBlindCCGet] payload: 0x0f2602 17:21:29.530 CNTRLR « [Node 014] received protection status: local: Unprotected rf Unprotected 17:21:29.531 CNTRLR [Node 014] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 17:21:29.531 CNTRLR [Node 014] FibaroVenetianBlindCC: doing a partial interview... 17:21:29.532 CNTRLR » [Node 014] Requesting venetian blind position and tilt... 17:21:29.542 SERIAL « [ACK] (0x06) 17:21:29.544 SERIAL « 0x0104011301e8 (6 bytes) 17:21:29.547 SERIAL » [ACK] (0x06) 17:21:29.550 DRIVER « [RES] [SendData] was sent: true 17:21:29.586 SERIAL « 0x0107001327000005c9 (9 bytes) 17:21:29.586 SERIAL » [ACK] (0x06) 17:21:29.587 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 17:21:29.640 SERIAL « 0x010e0004000d0891010f26030263002b (16 bytes) 17:21:29.642 CNTRLR [Node 013] [Manufacturer Proprietary] fibaro[venetianBlindsPositi [Endpoint 0] on]: metadata updated 17:21:29.643 CNTRLR [Node 013] [~] [Manufacturer Proprietary] fibaro[venetianBlindsPo [Endpoint 0] sition]: 1 => 99 17:21:29.644 SERIAL » [ACK] (0x06) 17:21:29.645 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[FibaroVenetianBlindCCReport] position: 99 17:21:29.648 SERIAL » 0x010c00130e0591010f260225285d (14 bytes) 17:21:29.649 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 40 └─[FibaroVenetianBlindCCGet] payload: 0x0f2602 17:21:29.649 CNTRLR « [Node 013] received venetian blind state: position: 99 tilt: undefined 17:21:29.649 CNTRLR [Node 013] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 17:21:29.650 CNTRLR [Node 013] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 17:21:29.676 SERIAL « [ACK] (0x06) 17:21:29.680 SERIAL « 0x0104011301e8 (6 bytes) 17:21:29.681 SERIAL » [ACK] (0x06) 17:21:29.682 DRIVER « [RES] [SendData] was sent: true 17:21:29.684 CNTRLR [Node 013] MultiChannelAssociationCC: doing a partial interview... 17:21:29.685 CNTRLR » [Node 013] querying multi channel association group #1... 17:21:29.726 SERIAL « 0x0107001328000007c4 (9 bytes) 17:21:29.727 SERIAL » [ACK] (0x06) 17:21:29.727 DRIVER « [REQ] [SendData] callback id: 40 transmit status: OK 17:21:29.738 SERIAL « 0x010e0004000e0891010f260302630028 (16 bytes) 17:21:29.739 CNTRLR [Node 014] [Manufacturer Proprietary] fibaro[venetianBlindsPositi [Endpoint 0] on]: metadata updated 17:21:29.740 CNTRLR [Node 014] [~] [Manufacturer Proprietary] fibaro[venetianBlindsPo [Endpoint 0] sition]: 1 => 99 17:21:29.740 SERIAL » [ACK] (0x06) 17:21:29.742 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[FibaroVenetianBlindCCReport] position: 99 17:21:29.762 SERIAL » 0x010a00130d038e0201252969 (12 bytes) 17:21:29.763 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 41 └─[MultiChannelAssociationCCGet] group id: 1 17:21:29.763 CNTRLR « [Node 014] received venetian blind state: position: 99 tilt: undefined 17:21:29.764 CNTRLR [Node 014] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 17:21:29.764 CNTRLR [Node 014] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 17:21:29.765 CNTRLR [Node 014] MultiChannelAssociationCC: doing a partial interview... 17:21:29.765 CNTRLR » [Node 014] querying multi channel association group #1... 17:21:29.769 SERIAL « [ACK] (0x06) 17:21:29.771 SERIAL « 0x0104011301e8 (6 bytes) 17:21:29.772 SERIAL » [ACK] (0x06) 17:21:29.772 DRIVER « [RES] [SendData] was sent: true 17:21:29.817 SERIAL « 0x0107001329000005c7 (9 bytes) 17:21:29.818 SERIAL » [ACK] (0x06) 17:21:29.819 DRIVER « [REQ] [SendData] callback id: 41 transmit status: OK 17:21:29.871 SERIAL « 0x010b0004000d058e0301070073 (13 bytes) 17:21:29.871 SERIAL » [ACK] (0x06) 17:21:29.873 CNTRLR [Node 013] [~] [Multi Channel Association] maxNodes[1]: 7 => 7 17:21:29.874 CNTRLR [Node 013] [~] [Multi Channel Association] nodeIds[1]: => 17:21:29.876 CNTRLR [Node 013] [~] [Multi Channel Association] endpoints[1]: => 17:21:29.877 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 7 node ids: endpoints: 17:21:29.882 SERIAL » 0x010a00130e038e0201252a69 (12 bytes) 17:21:29.882 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 42 └─[MultiChannelAssociationCCGet] group id: 1 17:21:29.883 CNTRLR « [Node 013] received information for multi channel association group #1: maximum # of nodes: 7 currently assigned nodes: currently assigned endpoints: 17:21:29.883 CNTRLR » [Node 013] querying multi channel association group #2... 17:21:29.886 SERIAL « [ACK] (0x06) 17:21:29.891 SERIAL « 0x0104011301e8 (6 bytes) 17:21:29.892 SERIAL » [ACK] (0x06) 17:21:29.893 DRIVER « [RES] [SendData] was sent: true 17:21:29.966 SERIAL « 0x010700132a000008c9 (9 bytes) 17:21:29.966 SERIAL » [ACK] (0x06) 17:21:29.967 DRIVER « [REQ] [SendData] callback id: 42 transmit status: OK 17:21:29.976 SERIAL « 0x010b0004000e058e0301070070 (13 bytes) 17:21:29.977 SERIAL » [ACK] (0x06) 17:21:29.978 CNTRLR [Node 014] [~] [Multi Channel Association] maxNodes[1]: 7 => 7 17:21:29.978 CNTRLR [Node 014] [~] [Multi Channel Association] nodeIds[1]: => 17:21:29.979 CNTRLR [Node 014] [~] [Multi Channel Association] endpoints[1]: => 17:21:29.980 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 7 node ids: endpoints: 17:21:29.983 SERIAL » 0x010a00130d038e0202252b68 (12 bytes) 17:21:29.984 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 43 └─[MultiChannelAssociationCCGet] group id: 2 17:21:29.984 CNTRLR « [Node 014] received information for multi channel association group #1: maximum # of nodes: 7 currently assigned nodes: currently assigned endpoints: 17:21:29.984 CNTRLR » [Node 014] querying multi channel association group #2... 17:21:29.988 SERIAL « [ACK] (0x06) 17:21:29.992 SERIAL « 0x0104011301e8 (6 bytes) 17:21:29.993 SERIAL » [ACK] (0x06) 17:21:29.994 DRIVER « [RES] [SendData] was sent: true 17:21:30.038 SERIAL « 0x010700132b000005c5 (9 bytes) 17:21:30.039 SERIAL » [ACK] (0x06) 17:21:30.039 DRIVER « [REQ] [SendData] callback id: 43 transmit status: OK 17:21:30.095 SERIAL « 0x010b0004000d058e0302070070 (13 bytes) 17:21:30.096 SERIAL » [ACK] (0x06) 17:21:30.097 CNTRLR [Node 013] [~] [Multi Channel Association] maxNodes[2]: 7 => 7 17:21:30.098 CNTRLR [Node 013] [~] [Multi Channel Association] nodeIds[2]: => 17:21:30.099 CNTRLR [Node 013] [~] [Multi Channel Association] endpoints[2]: => 17:21:30.100 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 7 node ids: endpoints: 17:21:30.103 SERIAL » 0x010a00130e038e0202252c6c (12 bytes) 17:21:30.104 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 44 └─[MultiChannelAssociationCCGet] group id: 2 17:21:30.104 CNTRLR « [Node 013] received information for multi channel association group #2: maximum # of nodes: 7 currently assigned nodes: currently assigned endpoints: 17:21:30.105 CNTRLR » [Node 013] querying additional non-multi-channel association groups... 17:21:30.105 CNTRLR » [Node 013] querying association group #3... 17:21:30.109 SERIAL « [ACK] (0x06) 17:21:30.114 SERIAL « 0x0104011301e8 (6 bytes) 17:21:30.115 SERIAL » [ACK] (0x06) 17:21:30.118 DRIVER « [RES] [SendData] was sent: true 17:21:30.186 SERIAL « 0x010700132c000008cf (9 bytes) 17:21:30.186 SERIAL » [ACK] (0x06) 17:21:30.186 DRIVER « [REQ] [SendData] callback id: 44 transmit status: OK 17:21:30.196 SERIAL « 0x010b0004000e058e0302070073 (13 bytes) 17:21:30.197 SERIAL » [ACK] (0x06) 17:21:30.197 CNTRLR [Node 014] [~] [Multi Channel Association] maxNodes[2]: 7 => 7 17:21:30.198 CNTRLR [Node 014] [~] [Multi Channel Association] nodeIds[2]: => 17:21:30.199 CNTRLR [Node 014] [~] [Multi Channel Association] endpoints[2]: => 17:21:30.206 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 7 node ids: endpoints: 17:21:30.210 SERIAL » 0x010a00130d03850203252d64 (12 bytes) 17:21:30.210 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 45 └─[AssociationCCGet] group id: 3 17:21:30.211 CNTRLR « [Node 014] received information for multi channel association group #2: maximum # of nodes: 7 currently assigned nodes: currently assigned endpoints: 17:21:30.211 CNTRLR » [Node 014] querying additional non-multi-channel association groups... 17:21:30.211 CNTRLR » [Node 014] querying association group #3... 17:21:30.215 SERIAL « [ACK] (0x06) 17:21:30.219 SERIAL « 0x0104011301e8 (6 bytes) 17:21:30.220 SERIAL » [ACK] (0x06) 17:21:30.221 DRIVER « [RES] [SendData] was sent: true 17:21:30.265 SERIAL « 0x010700132d000005c3 (9 bytes) 17:21:30.266 SERIAL » [ACK] (0x06) 17:21:30.266 DRIVER « [REQ] [SendData] callback id: 45 transmit status: OK 17:21:30.319 SERIAL « 0x010c0004000d0685030301000179 (14 bytes) 17:21:30.320 SERIAL » [ACK] (0x06) 17:21:30.321 CNTRLR [Node 013] [~] [Association] maxNodes[3]: 1 => 1 [internal] 17:21:30.321 CNTRLR [Node 013] [~] [Association] nodeIds[3]: 1 => 1 [internal] 17:21:30.322 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 17:21:30.326 SERIAL » 0x010a00130e03850203252e64 (12 bytes) 17:21:30.327 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 46 └─[AssociationCCGet] group id: 3 17:21:30.327 CNTRLR « [Node 013] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 17:21:30.328 CNTRLR [Node 013] [~] [Association] hasLifeline: true => true [internal] 17:21:30.328 CNTRLR [Node 013] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:21:30.367 SERIAL « [ACK] (0x06) 17:21:30.372 SERIAL « 0x0104011301e8 (6 bytes) 17:21:30.372 SERIAL » [ACK] (0x06) 17:21:30.374 DRIVER « [RES] [SendData] was sent: true 17:21:30.376 CNTRLR [Node 013] Interview stage completed: CommandClasses 17:21:30.376 CNTRLR [Node 013] Interview stage completed: OverwriteConfig 17:21:30.377 CNTRLR » [Node 013] requesting node neighbors... 17:21:30.406 SERIAL « 0x010700132e000007c2 (9 bytes) 17:21:30.406 SERIAL » [ACK] (0x06) 17:21:30.407 DRIVER « [REQ] [SendData] callback id: 46 transmit status: OK 17:21:30.416 SERIAL « 0x010c0004000e068503030100017a (14 bytes) 17:21:30.417 SERIAL » [ACK] (0x06) 17:21:30.418 CNTRLR [Node 014] [~] [Association] maxNodes[3]: 1 => 1 [internal] 17:21:30.419 CNTRLR [Node 014] [~] [Association] nodeIds[3]: 1 => 1 [internal] 17:21:30.419 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 17:21:30.423 SERIAL » 0x010700800d00000075 (9 bytes) 17:21:30.424 DRIVER » [Node 013] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:21:30.424 CNTRLR « [Node 014] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 17:21:30.425 CNTRLR [Node 014] [~] [Association] hasLifeline: true => true [internal] 17:21:30.425 CNTRLR [Node 014] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:21:30.426 CNTRLR [Node 014] Interview stage completed: CommandClasses 17:21:30.426 CNTRLR [Node 014] Interview stage completed: OverwriteConfig 17:21:30.426 CNTRLR » [Node 014] requesting node neighbors... 17:21:30.430 SERIAL « [ACK] (0x06) 17:21:30.431 SERIAL « 0x0120018005e8fc5f0700000000000000000000000000000000000000000000000 (34 bytes) 017 17:21:30.432 SERIAL » [ACK] (0x06) 17:21:30.433 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 12, 14, 15, 16, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 31, 33, 34, 35 17:21:30.438 SERIAL » 0x010700800e00000076 (9 bytes) 17:21:30.439 DRIVER » [Node 014] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:21:30.439 CNTRLR « [Node 013] node neighbors received: 1, 3, 12, 14, 15, 16, 19, 20, 21, 22, 23 , 24, 25, 26, 27, 28, 29, 31, 33, 34, 35 17:21:30.440 CNTRLR [Node 013] Interview stage completed: Neighbors 17:21:30.440 CNTRLR [Node 013] Interview completed 17:21:30.444 SERIAL « [ACK] (0x06) 17:21:30.445 SERIAL « 0x0120018065d9fc7f0700000000000000000000000000000000000000000000000 (34 bytes) 066 17:21:30.445 SERIAL » [ACK] (0x06) 17:21:30.446 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 9, 12, 13, 15, 16, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 33, 34, 35 17:21:30.452 SERIAL » 0x010a00131003700528252fa2 (12 bytes) 17:21:30.452 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 47 └─[ConfigurationCCGet] parameter #: 40 17:21:30.453 CNTRLR « [Node 014] node neighbors received: 1, 3, 6, 7, 9, 12, 13, 15, 16, 19, 20, 2 1, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 33, 34, 35 17:21:30.453 CNTRLR [Node 014] Interview stage completed: Neighbors 17:21:30.453 CNTRLR [Node 014] Interview completed 17:21:30.456 SERIAL « [ACK] (0x06) 17:21:30.460 SERIAL « 0x0104011301e8 (6 bytes) 17:21:30.461 SERIAL » [ACK] (0x06) 17:21:30.461 DRIVER « [RES] [SendData] was sent: true 17:21:30.499 SERIAL « 0x010700132f000005c1 (9 bytes) 17:21:30.500 SERIAL » [ACK] (0x06) 17:21:30.500 DRIVER « [REQ] [SendData] callback id: 47 transmit status: OK 17:21:30.563 SERIAL « 0x010b0004001005700628010ab0 (13 bytes) 17:21:30.568 CNTRLR [Node 016] [~] [Configuration] 40: 10 => 10 17:21:30.569 SERIAL » [ACK] (0x06) 17:21:30.572 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 10 17:21:30.575 SERIAL » 0x010a00130c0370052a2530a3 (12 bytes) 17:21:30.576 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 48 └─[ConfigurationCCGet] parameter #: 42 17:21:30.576 CNTRLR « [Node 016] parameter #40 has value: 10 17:21:30.576 CNTRLR » [Node 016] querying parameter #42 value... 17:21:30.581 SERIAL « [ACK] (0x06) 17:21:30.585 SERIAL « 0x0104011301e8 (6 bytes) 17:21:30.585 SERIAL » [ACK] (0x06) 17:21:30.586 DRIVER « [RES] [SendData] was sent: true 17:21:30.635 SERIAL « 0x0107001330000006dd (9 bytes) 17:21:30.636 SERIAL » [ACK] (0x06) 17:21:30.636 DRIVER « [REQ] [SendData] callback id: 48 transmit status: OK 17:21:30.646 SERIAL « 0x010c0004000c0670062a020e10bd (14 bytes) 17:21:30.651 CNTRLR [Node 012] [~] [Configuration] 42: 3600 => 3600 17:21:30.652 SERIAL » [ACK] (0x06) 17:21:30.653 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 3600 17:21:30.656 SERIAL » 0x010a0013100370052a2531be (12 bytes) 17:21:30.657 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 49 └─[ConfigurationCCGet] parameter #: 42 17:21:30.657 CNTRLR « [Node 012] parameter #42 has value: 3600 17:21:30.658 CNTRLR » [Node 012] querying parameter #43 value... 17:21:30.661 SERIAL « [ACK] (0x06) 17:21:30.665 SERIAL « 0x0104011301e8 (6 bytes) 17:21:30.666 SERIAL » [ACK] (0x06) 17:21:30.667 DRIVER « [RES] [SendData] was sent: true 17:21:30.703 SERIAL « 0x0107001331000004de (9 bytes) 17:21:30.704 SERIAL » [ACK] (0x06) 17:21:30.704 DRIVER « [REQ] [SendData] callback id: 49 transmit status: OK 17:21:30.752 SERIAL « 0x010c000400100670062a020e10a1 (14 bytes) 17:21:30.757 CNTRLR [Node 016] [~] [Configuration] 42: 3600 => 3600 17:21:30.758 SERIAL » [ACK] (0x06) 17:21:30.759 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 3600 17:21:30.762 SERIAL » 0x010a00130c0370052b2532a0 (12 bytes) 17:21:30.762 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 50 └─[ConfigurationCCGet] parameter #: 43 17:21:30.763 CNTRLR « [Node 016] parameter #42 has value: 3600 17:21:30.763 CNTRLR » [Node 016] querying parameter #43 value... 17:21:30.766 SERIAL « [ACK] (0x06) 17:21:30.771 SERIAL « 0x0104011301e8 (6 bytes) 17:21:30.772 SERIAL » [ACK] (0x06) 17:21:30.773 DRIVER « [RES] [SendData] was sent: true 17:21:30.835 SERIAL « 0x0107001332000007de (9 bytes) 17:21:30.836 SERIAL » [ACK] (0x06) 17:21:30.837 DRIVER « [REQ] [SendData] callback id: 50 transmit status: OK 17:21:30.846 SERIAL « 0x010b0004000c0570062b010aaf (13 bytes) 17:21:30.852 CNTRLR [Node 012] [~] [Configuration] 43: 10 => 10 17:21:30.852 SERIAL » [ACK] (0x06) 17:21:30.853 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 10 17:21:30.858 SERIAL » 0x010a0013100370052b2533bd (12 bytes) 17:21:30.859 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 51 └─[ConfigurationCCGet] parameter #: 43 17:21:30.859 CNTRLR « [Node 012] parameter #43 has value: 10 17:21:30.860 CNTRLR » [Node 012] querying parameter #44 value... 17:21:30.863 SERIAL « [ACK] (0x06) 17:21:30.867 SERIAL « 0x0104011301e8 (6 bytes) 17:21:30.868 SERIAL » [ACK] (0x06) 17:21:30.868 DRIVER « [RES] [SendData] was sent: true 17:21:30.906 SERIAL « 0x0107001333000004dc (9 bytes) 17:21:30.906 SERIAL » [ACK] (0x06) 17:21:30.907 DRIVER « [REQ] [SendData] callback id: 51 transmit status: OK 17:21:30.954 SERIAL « 0x010b000400100570062b010ab3 (13 bytes) 17:21:30.960 CNTRLR [Node 016] [~] [Configuration] 43: 10 => 10 17:21:30.960 SERIAL » [ACK] (0x06) 17:21:30.961 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 10 17:21:30.965 SERIAL » 0x010a00130c0370052c2534a1 (12 bytes) 17:21:30.966 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 52 └─[ConfigurationCCGet] parameter #: 44 17:21:30.966 CNTRLR « [Node 016] parameter #43 has value: 10 17:21:30.967 CNTRLR » [Node 016] querying parameter #44 value... 17:21:30.970 SERIAL « [ACK] (0x06) 17:21:30.974 SERIAL « 0x0104011301e8 (6 bytes) 17:21:30.975 SERIAL » [ACK] (0x06) 17:21:30.975 DRIVER « [RES] [SendData] was sent: true 17:21:31.036 SERIAL « 0x0107001334000006d9 (9 bytes) 17:21:31.036 SERIAL » [ACK] (0x06) 17:21:31.037 DRIVER « [REQ] [SendData] callback id: 52 transmit status: OK 17:21:31.046 SERIAL « 0x010b0004000c0570062c0100a2 (13 bytes) 17:21:31.052 CNTRLR [Node 012] [~] [Configuration] 44: 0 => 0 17:21:31.053 SERIAL » [ACK] (0x06) 17:21:31.054 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 44 value size: 1 value: 0 17:21:31.058 SERIAL » 0x010a0013100370052c2535bc (12 bytes) 17:21:31.058 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 53 └─[ConfigurationCCGet] parameter #: 44 17:21:31.059 CNTRLR « [Node 012] parameter #44 has value: 0 17:21:31.059 CNTRLR » [Node 012] querying parameter #50 value... 17:21:31.063 SERIAL « [ACK] (0x06) 17:21:31.067 SERIAL « 0x0104011301e8 (6 bytes) 17:21:31.067 SERIAL » [ACK] (0x06) 17:21:31.068 DRIVER « [RES] [SendData] was sent: true 17:21:31.105 SERIAL « 0x0107001335000004da (9 bytes) 17:21:31.106 SERIAL » [ACK] (0x06) 17:21:31.106 DRIVER « [REQ] [SendData] callback id: 53 transmit status: OK 17:21:31.154 SERIAL « 0x010b000400100570062c0100be (13 bytes) 17:21:31.159 CNTRLR [Node 016] [~] [Configuration] 44: 0 => 0 17:21:31.160 SERIAL » [ACK] (0x06) 17:21:31.161 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 44 value size: 1 value: 0 17:21:31.164 SERIAL » 0x010a00130c037005322536bd (12 bytes) 17:21:31.165 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 54 └─[ConfigurationCCGet] parameter #: 50 17:21:31.165 CNTRLR « [Node 016] parameter #44 has value: 0 17:21:31.165 CNTRLR » [Node 016] querying parameter #50 value... 17:21:31.169 SERIAL « [ACK] (0x06) 17:21:31.174 SERIAL « 0x0104011301e8 (6 bytes) 17:21:31.174 SERIAL » [ACK] (0x06) 17:21:31.175 DRIVER « [RES] [SendData] was sent: true 17:21:31.255 SERIAL « 0x0107001336000007da (9 bytes) 17:21:31.255 SERIAL » [ACK] (0x06) 17:21:31.257 DRIVER « [REQ] [SendData] callback id: 54 transmit status: OK 17:21:31.261 SERIAL « 0x010b0004000c057006320100bc (13 bytes) 17:21:31.268 CNTRLR [Node 012] [~] [Configuration] 50: 0 => 0 17:21:31.269 SERIAL » [ACK] (0x06) 17:21:31.270 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 0 17:21:31.275 SERIAL » 0x010a001310037005322537a0 (12 bytes) 17:21:31.276 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 55 └─[ConfigurationCCGet] parameter #: 50 17:21:31.276 CNTRLR « [Node 012] parameter #50 has value: 0 17:21:31.277 CNTRLR [Node 012] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:21:31.305 SERIAL « [ACK] (0x06) 17:21:31.310 SERIAL « 0x0104011301e8 (6 bytes) 17:21:31.311 SERIAL » [ACK] (0x06) 17:21:31.314 DRIVER « [RES] [SendData] was sent: true 17:21:31.317 CNTRLR [Node 012] ProtectionCC: doing a partial interview... 17:21:31.317 CNTRLR » [Node 012] querying protection status... 17:21:31.366 SERIAL « 0x0107001337000005d9 (9 bytes) 17:21:31.367 SERIAL » [ACK] (0x06) 17:21:31.368 DRIVER « [REQ] [SendData] callback id: 55 transmit status: OK 17:21:31.372 SERIAL « 0x010b00040010057006320100a0 (13 bytes) 17:21:31.383 CNTRLR [Node 016] [~] [Configuration] 50: 0 => 0 17:21:31.385 SERIAL » [ACK] (0x06) 17:21:31.386 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 0 17:21:31.393 SERIAL » 0x010900130c027502253881 (11 bytes) 17:21:31.394 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 56 └─[ProtectionCCGet] 17:21:31.395 CNTRLR « [Node 016] parameter #50 has value: 0 17:21:31.395 CNTRLR [Node 016] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:21:31.396 CNTRLR [Node 016] ProtectionCC: doing a partial interview... 17:21:31.396 CNTRLR » [Node 016] querying protection status... 17:21:31.405 SERIAL « [ACK] (0x06) 17:21:31.406 SERIAL « 0x0104011301e8 (6 bytes) 17:21:31.407 SERIAL » [ACK] (0x06) 17:21:31.409 DRIVER « [RES] [SendData] was sent: true 17:21:31.455 SERIAL « 0x0107001338000006d5 (9 bytes) 17:21:31.456 SERIAL » [ACK] (0x06) 17:21:31.456 DRIVER « [REQ] [SendData] callback id: 56 transmit status: OK 17:21:31.466 SERIAL « 0x010a0004000c04750300008f (12 bytes) 17:21:31.467 CNTRLR [Node 012] [~] [Protection] local: 0 => 0 [Endpoint 0] 17:21:31.467 CNTRLR [Node 012] [~] [Protection] rf: 0 => 0 [Endpoint 0] 17:21:31.468 SERIAL » [ACK] (0x06) 17:21:31.469 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 17:21:31.472 SERIAL » 0x010900131002750225399c (11 bytes) 17:21:31.473 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 57 └─[ProtectionCCGet] 17:21:31.473 CNTRLR « [Node 012] received protection status: local: Unprotected rf Unprotected 17:21:31.474 CNTRLR [Node 012] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 17:21:31.502 SERIAL « [ACK] (0x06) 17:21:31.506 SERIAL « 0x0104011301e8 (6 bytes) 17:21:31.506 SERIAL » [ACK] (0x06) 17:21:31.508 DRIVER « [RES] [SendData] was sent: true 17:21:31.513 CNTRLR [Node 012] FibaroVenetianBlindCC: doing a partial interview... 17:21:31.513 CNTRLR » [Node 012] Requesting venetian blind position and tilt... 17:21:31.519 SERIAL « 0x0107001339000004d6 (9 bytes) 17:21:31.519 SERIAL » [ACK] (0x06) 17:21:31.520 DRIVER « [REQ] [SendData] callback id: 57 transmit status: OK 17:21:31.565 SERIAL « 0x010a00040010047503000093 (12 bytes) 17:21:31.566 CNTRLR [Node 016] [~] [Protection] local: 0 => 0 [Endpoint 0] 17:21:31.567 CNTRLR [Node 016] [~] [Protection] rf: 0 => 0 [Endpoint 0] 17:21:31.567 SERIAL » [ACK] (0x06) 17:21:31.568 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 17:21:31.575 SERIAL » 0x01080013110100253aeb (10 bytes) 17:21:31.576 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 58 └─[NoOperationCC] 17:21:31.576 CNTRLR « [Node 016] received protection status: local: Unprotected rf Unprotected 17:21:31.576 CNTRLR [Node 016] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 17:21:31.577 CNTRLR [Node 016] FibaroVenetianBlindCC: doing a partial interview... 17:21:31.577 CNTRLR » [Node 016] Requesting venetian blind position and tilt... 17:21:31.580 SERIAL « [ACK] (0x06) 17:21:31.584 SERIAL « 0x0104011301e8 (6 bytes) 17:21:31.584 SERIAL » [ACK] (0x06) 17:21:31.585 DRIVER « [RES] [SendData] was sent: true 17:21:36.858 SERIAL « 0x010c00040003063105042204c024 (14 bytes) 17:21:36.859 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:21:36.859 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 216.9 => 121.6 [Endpoint 0] 17:21:36.860 SERIAL » [ACK] (0x06) 17:21:36.861 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 121.6 17:21:41.040 SERIAL « 0x010700133a0103b360 (9 bytes) 17:21:41.041 SERIAL » [ACK] (0x06) 17:21:41.042 DRIVER « [REQ] [SendData] callback id: 58 transmit status: NoAck 17:21:41.050 SERIAL » 0x01080013120100253be9 (10 bytes) 17:21:41.050 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 59 └─[NoOperationCC] 17:21:41.051 CNTRLR [Node 017] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 17:21:41.051 CNTRLR [Node 017] The node is asleep. 17:21:41.053 CNTRLR [Node 017] The node is ready to be used 17:21:41.055 CNTRLR [Node 017] ping failed: Failed to send the command after 1 attempts (Status No Ack) 17:21:41.059 CNTRLR [Node 017] ManufacturerSpecificCC: doing a partial interview... 17:21:41.059 CNTRLR [Node 017] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:21:41.107 SERIAL « [ACK] (0x06) 17:21:41.112 SERIAL « 0x0104011301e8 (6 bytes) 17:21:41.113 SERIAL » [ACK] (0x06) 17:21:41.114 DRIVER « [RES] [SendData] was sent: true 17:21:41.120 CNTRLR [Node 017] VersionCC: doing a partial interview... 17:21:41.120 CNTRLR [Node 017] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:21:41.121 CNTRLR [Node 017] trying to load device config 17:21:41.138 CNTRLR [Node 017] device config loaded 17:21:41.139 CNTRLR [Node 017] BatteryCC: doing a partial interview... 17:21:41.139 CNTRLR » [Node 017] querying battery status... 17:21:42.600 SERIAL « 0x010700133b00009b4b (9 bytes) 17:21:42.600 SERIAL » [ACK] (0x06) 17:21:42.601 DRIVER « [REQ] [SendData] callback id: 59 transmit status: OK 17:21:42.605 SERIAL » 0x01080013130100253cef (10 bytes) 17:21:42.606 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 60 └─[NoOperationCC] 17:21:42.606 CNTRLR « [Node 018] ping successful 17:21:42.608 CNTRLR [Node 018] ManufacturerSpecificCC: doing a partial interview... 17:21:42.609 CNTRLR [Node 018] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:21:42.638 SERIAL « [ACK] (0x06) 17:21:42.641 SERIAL « 0x0104011301e8 (6 bytes) 17:21:42.641 SERIAL » [ACK] (0x06) 17:21:42.642 DRIVER « [RES] [SendData] was sent: true 17:21:42.644 SERIAL « 0x010700133c000003d4 (9 bytes) 17:21:42.644 SERIAL » [ACK] (0x06) 17:21:42.645 CNTRLR [Node 018] VersionCC: doing a partial interview... 17:21:42.645 CNTRLR [Node 018] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:21:42.645 CNTRLR [Node 018] trying to load device config 17:21:42.647 DRIVER « [REQ] [SendData] callback id: 60 transmit status: OK 17:21:42.651 SERIAL » 0x01080013140100253de9 (10 bytes) 17:21:42.651 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 61 └─[NoOperationCC] 17:21:42.652 CNTRLR « [Node 019] ping successful 17:21:42.653 CNTRLR [Node 019] ManufacturerSpecificCC: doing a partial interview... 17:21:42.654 CNTRLR [Node 019] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:21:42.654 CNTRLR [Node 019] VersionCC: doing a partial interview... 17:21:42.655 CNTRLR [Node 019] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:21:42.655 CNTRLR [Node 019] trying to load device config 17:21:42.660 SERIAL « [ACK] (0x06) 17:21:42.662 SERIAL « 0x0104011301e8 (6 bytes) 17:21:42.663 SERIAL » [ACK] (0x06) 17:21:42.664 DRIVER « [RES] [SendData] was sent: true 17:21:42.673 CNTRLR [Node 018] device config loaded 17:21:42.675 CNTRLR [Node 018] ZWavePlusCC: doing a partial interview... 17:21:42.675 CNTRLR [Node 018] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 17:21:42.676 CNTRLR » [Node 018] querying device endpoint information... 17:21:42.699 CNTRLR [Node 019] device config loaded 17:21:42.700 CNTRLR [Node 019] AssociationCC: doing a partial interview... 17:21:42.701 CNTRLR » [Node 019] querying association group #1... 17:21:42.755 SERIAL « 0x010700133d00000adc (9 bytes) 17:21:42.755 SERIAL » [ACK] (0x06) 17:21:42.757 DRIVER « [REQ] [SendData] callback id: 61 transmit status: OK 17:21:42.761 SERIAL » 0x0109001312026007253e89 (11 bytes) 17:21:42.761 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 62 └─[MultiChannelCCEndPointGet] 17:21:42.762 CNTRLR « [Node 020] ping successful 17:21:42.763 CNTRLR [Node 020] ManufacturerSpecificCC: doing a partial interview... 17:21:42.763 CNTRLR [Node 020] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:21:42.763 CNTRLR [Node 020] VersionCC: doing a partial interview... 17:21:42.763 CNTRLR [Node 020] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:21:42.764 CNTRLR [Node 020] trying to load device config 17:21:42.766 SERIAL « [ACK] (0x06) 17:21:42.778 CNTRLR [Node 020] device config loaded 17:21:42.779 CNTRLR [Node 020] WakeUpCC: doing a complete interview... 17:21:42.779 CNTRLR » [Node 020] retrieving wakeup interval from the device... 17:21:42.781 SERIAL « 0x0104011301e8 (6 bytes) 17:21:42.782 SERIAL » [ACK] (0x06) 17:21:42.782 DRIVER « [RES] [SendData] was sent: true 17:21:42.844 SERIAL « 0x010700133e000008dd (9 bytes) 17:21:42.844 SERIAL » [ACK] (0x06) 17:21:42.844 DRIVER « [REQ] [SendData] callback id: 62 transmit status: OK 17:21:42.925 SERIAL « 0x010b000400120560080002008d (13 bytes) 17:21:42.926 CNTRLR [Node 018] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 17:21:42.926 CNTRLR [Node 018] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 17:21:42.927 CNTRLR [Node 018] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 17:21:42.927 CNTRLR [Node 018] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 17:21:42.927 SERIAL » [ACK] (0x06) 17:21:42.928 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 17:21:42.931 SERIAL » 0x0109001314028405253f68 (11 bytes) 17:21:42.932 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 63 └─[WakeUpCCIntervalGet] 17:21:42.932 CNTRLR [Node 018] The node is alive. 17:21:42.933 CNTRLR [Node 018] The node is ready to be used 17:21:42.934 CNTRLR « [Node 018] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 17:21:42.934 CNTRLR » [Node 018] querying all endpoints... 17:21:42.938 SERIAL « [ACK] (0x06) 17:21:42.943 SERIAL « 0x0104011301e8 (6 bytes) 17:21:42.943 SERIAL » [ACK] (0x06) 17:21:42.944 DRIVER « [RES] [SendData] was sent: true 17:21:43.682 SERIAL « 0x010700133f000010c4 (9 bytes) 17:21:43.683 SERIAL » [ACK] (0x06) 17:21:43.683 DRIVER « [REQ] [SendData] callback id: 63 transmit status: OK 17:21:43.815 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:21:43.816 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:21:43.817 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:21:43.817 SERIAL » [ACK] (0x06) 17:21:43.818 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:21:43.852 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:21:43.852 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:21:43.853 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:21:43.853 SERIAL » [ACK] (0x06) 17:21:43.854 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:21:43.880 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:21:43.881 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:21:43.881 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:21:43.882 SERIAL » [ACK] (0x06) 17:21:43.883 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:21:43.948 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:21:43.949 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:21:43.950 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:21:43.950 SERIAL » [ACK] (0x06) 17:21:43.952 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:21:43.960 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:21:43.961 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:21:43.962 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:21:43.963 SERIAL » [ACK] (0x06) 17:21:43.964 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:21:43.973 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:21:43.974 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:21:43.974 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:21:43.975 SERIAL » [ACK] (0x06) 17:21:43.976 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:21:44.048 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:21:44.049 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:21:44.049 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:21:44.050 SERIAL » [ACK] (0x06) 17:21:44.051 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:21:44.094 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:21:44.095 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:21:44.096 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:21:44.096 SERIAL » [ACK] (0x06) 17:21:44.097 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:21:44.177 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:21:44.178 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:21:44.179 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:21:44.179 SERIAL » [ACK] (0x06) 17:21:44.181 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:21:44.308 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:21:44.309 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:21:44.310 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:21:44.310 SERIAL » [ACK] (0x06) 17:21:44.312 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:21:44.370 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:21:44.371 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:21:44.372 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:21:44.373 SERIAL » [ACK] (0x06) 17:21:44.375 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:21:44.545 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:21:44.546 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:21:44.547 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:21:44.547 SERIAL » [ACK] (0x06) 17:21:44.548 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:21:45.286 CNTRLR [Node 020] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 17:21:45.792 SERIAL » 0x0109001314028405253f68 (11 bytes) 17:21:45.793 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 63 └─[WakeUpCCIntervalGet] 17:21:45.795 SERIAL « [ACK] (0x06) 17:21:45.802 SERIAL « 0x0104011301e8 (6 bytes) 17:21:45.803 SERIAL » [ACK] (0x06) 17:21:45.804 DRIVER « [RES] [SendData] was sent: true 17:21:45.899 SERIAL « 0x010700133f00000ade (9 bytes) 17:21:45.899 SERIAL » [ACK] (0x06) 17:21:45.900 DRIVER « [REQ] [SendData] callback id: 63 transmit status: OK 17:21:47.504 CNTRLR [Node 020] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 17:21:48.010 SERIAL » 0x0109001314028405253f68 (11 bytes) 17:21:48.011 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 63 └─[WakeUpCCIntervalGet] 17:21:48.013 SERIAL « [ACK] (0x06) 17:21:48.019 SERIAL « 0x0104011301e8 (6 bytes) 17:21:48.020 SERIAL » [ACK] (0x06) 17:21:48.021 DRIVER « [RES] [SendData] was sent: true 17:21:48.116 SERIAL « 0x010700133f00000ade (9 bytes) 17:21:48.117 SERIAL » [ACK] (0x06) 17:21:48.117 DRIVER « [REQ] [SendData] callback id: 63 transmit status: OK 17:21:49.725 SERIAL » 0x010a00131303850201254015 (12 bytes) 17:21:49.726 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 64 └─[AssociationCCGet] group id: 1 17:21:49.727 CNTRLR [Node 020] Interview attempt 1/5 failed, retrying in 5000 ms... 17:21:49.728 SERIAL « [ACK] (0x06) 17:21:49.734 SERIAL « 0x0104011301e8 (6 bytes) 17:21:49.735 SERIAL » [ACK] (0x06) 17:21:49.736 DRIVER « [RES] [SendData] was sent: true 17:21:49.752 SERIAL « 0x0107001340000002a9 (9 bytes) 17:21:49.752 SERIAL » [ACK] (0x06) 17:21:49.753 DRIVER « [REQ] [SendData] callback id: 64 transmit status: OK 17:21:49.762 SERIAL « 0x010b0004001305850301100071 (13 bytes) 17:21:49.763 SERIAL » [ACK] (0x06) 17:21:49.765 CNTRLR [Node 019] [~] [Association] maxNodes[1]: 16 => 16 [internal] 17:21:49.766 CNTRLR [Node 019] [~] [Association] nodeIds[1]: => [internal] 17:21:49.766 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 1 max # of nodes: 16 node IDs: reports to follow: 0 17:21:49.775 SERIAL » 0x010b00131204600bffff2541fe (13 bytes) 17:21:49.778 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 65 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 17:21:49.778 CNTRLR [Node 019] The node is alive. 17:21:49.780 CNTRLR [Node 019] The node is ready to be used 17:21:49.782 CNTRLR « [Node 019] received information for association group #1: maximum # of nodes: 16 currently assigned nodes: 17:21:49.782 CNTRLR » [Node 019] querying association group #2... 17:21:49.789 SERIAL « [ACK] (0x06) 17:21:49.792 SERIAL « 0x0104011301e8 (6 bytes) 17:21:49.793 SERIAL » [ACK] (0x06) 17:21:49.794 DRIVER « [RES] [SendData] was sent: true 17:21:51.271 SERIAL « 0x01070013410000953f (9 bytes) 17:21:51.272 SERIAL » [ACK] (0x06) 17:21:51.288 DRIVER « [REQ] [SendData] callback id: 65 transmit status: OK 17:21:51.444 SERIAL « 0x010d0004001207600c00ffff01028c (15 bytes) 17:21:51.445 SERIAL » [ACK] (0x06) 17:21:51.447 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 17:21:51.452 SERIAL » 0x010a00131303850202254214 (12 bytes) 17:21:51.453 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 66 └─[AssociationCCGet] group id: 2 17:21:51.453 CNTRLR « [Node 018] received endpoints: 1, 2 17:21:51.453 CNTRLR » [Node 018] querying capabilities for endpoint #1... 17:21:51.457 SERIAL « [ACK] (0x06) 17:21:51.461 SERIAL « 0x0104011301e8 (6 bytes) 17:21:51.461 SERIAL » [ACK] (0x06) 17:21:51.462 DRIVER « [RES] [SendData] was sent: true 17:21:51.535 SERIAL « 0x0107001342000008a1 (9 bytes) 17:21:51.536 SERIAL » [ACK] (0x06) 17:21:51.536 DRIVER « [REQ] [SendData] callback id: 66 transmit status: OK 17:21:51.546 SERIAL « 0x010b0004001305850302100072 (13 bytes) 17:21:51.547 SERIAL » [ACK] (0x06) 17:21:51.548 CNTRLR [Node 019] [~] [Association] maxNodes[2]: 16 => 16 [internal] 17:21:51.548 CNTRLR [Node 019] [~] [Association] nodeIds[2]: => [internal] 17:21:51.549 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 2 max # of nodes: 16 node IDs: reports to follow: 0 17:21:51.552 SERIAL » 0x010a001312036009012543f9 (12 bytes) 17:21:51.553 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 67 └─[MultiChannelCCCapabilityGet] endpoint: 1 17:21:51.553 CNTRLR « [Node 019] received information for association group #2: maximum # of nodes: 16 currently assigned nodes: 17:21:51.553 CNTRLR » [Node 019] querying association group #3... 17:21:51.556 SERIAL « [ACK] (0x06) 17:21:51.561 SERIAL « 0x0104011301e8 (6 bytes) 17:21:51.561 SERIAL » [ACK] (0x06) 17:21:51.561 DRIVER « [RES] [SendData] was sent: true 17:21:51.636 SERIAL « 0x0107001343000008a0 (9 bytes) 17:21:51.636 SERIAL » [ACK] (0x06) 17:21:51.637 DRIVER « [REQ] [SendData] callback id: 67 transmit status: OK 17:21:51.724 SERIAL « 0x011a0004001214600a0108065e8e404353989f596c71758081852292 (28 bytes) 17:21:51.726 CNTRLR [Node 018] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 1] [internal] 64,67,83,152,159,89,108,113,117,128,129,133,34 => 94,142,64,67,83,152,159,89,1 08,113,117,128,129,133,34 17:21:51.727 SERIAL » [ACK] (0x06) 17:21:51.728 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 17:21:51.731 SERIAL » 0x010a00131303850203254413 (12 bytes) 17:21:51.731 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 68 └─[AssociationCCGet] group id: 3 17:21:51.732 CNTRLR « [Node 018] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 17:21:51.732 CNTRLR » [Node 018] querying capabilities for endpoint #2... 17:21:51.735 SERIAL « [ACK] (0x06) 17:21:51.739 SERIAL « 0x0104011301e8 (6 bytes) 17:21:51.740 SERIAL » [ACK] (0x06) 17:21:51.740 DRIVER « [RES] [SendData] was sent: true 17:21:51.815 SERIAL « 0x0107001344000008a7 (9 bytes) 17:21:51.816 SERIAL » [ACK] (0x06) 17:21:51.816 DRIVER « [REQ] [SendData] callback id: 68 transmit status: OK 17:21:51.826 SERIAL « 0x010c000400130685030301000167 (14 bytes) 17:21:51.827 SERIAL » [ACK] (0x06) 17:21:51.828 CNTRLR [Node 019] [~] [Association] maxNodes[3]: 1 => 1 [internal] 17:21:51.828 CNTRLR [Node 019] [~] [Association] nodeIds[3]: 1 => 1 [internal] 17:21:51.828 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 17:21:51.831 SERIAL » 0x010a001312036009022545fc (12 bytes) 17:21:51.832 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 69 └─[MultiChannelCCCapabilityGet] endpoint: 2 17:21:51.832 CNTRLR « [Node 019] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 17:21:51.833 CNTRLR [Node 019] [~] [Association] hasLifeline: true => true [internal] 17:21:51.833 CNTRLR [Node 019] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:21:51.864 SERIAL « [ACK] (0x06) 17:21:51.867 SERIAL « 0x0104011301e8 (6 bytes) 17:21:51.867 SERIAL » [ACK] (0x06) 17:21:51.868 DRIVER « [RES] [SendData] was sent: true 17:21:51.870 CNTRLR [Node 019] BinarySwitchCC: doing a partial interview... 17:21:51.871 CNTRLR » [Node 019] querying Binary Switch state... 17:21:51.915 SERIAL « 0x0107001345000008a6 (9 bytes) 17:21:51.915 SERIAL » [ACK] (0x06) 17:21:51.923 DRIVER « [REQ] [SendData] callback id: 69 transmit status: OK 17:21:52.000 SERIAL « 0x01160004001210600a0221015e8e31989f596c7180852222 (24 bytes) 17:21:52.001 CNTRLR [Node 018] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 2] [internal] 49,152,159,89,108,113,128,133,34 => 94,142,49,152,159,89,108,113,128,133,34 17:21:52.001 SERIAL » [ACK] (0x06) 17:21:52.002 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 17:21:52.007 SERIAL » 0x01090013130225022546b0 (11 bytes) 17:21:52.007 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 70 └─[BinarySwitchCCGet] 17:21:52.008 CNTRLR « [Node 018] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 17:21:52.008 CNTRLR [Node 018] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 17:21:52.009 CNTRLR [Node 018] BatteryCC: doing a partial interview... 17:21:52.009 CNTRLR » [Node 018] querying battery status... 17:21:52.012 SERIAL « [ACK] (0x06) 17:21:52.015 SERIAL « 0x0104011301e8 (6 bytes) 17:21:52.016 SERIAL » [ACK] (0x06) 17:21:52.016 DRIVER « [RES] [SendData] was sent: true 17:21:52.041 SERIAL « 0x0107001346000003ae (9 bytes) 17:21:52.041 SERIAL » [ACK] (0x06) 17:21:52.042 DRIVER « [REQ] [SendData] callback id: 70 transmit status: OK 17:21:52.051 SERIAL « 0x010900040013032503ff3b (11 bytes) 17:21:52.052 CNTRLR [Node 019] [~] [Binary Switch] currentValue: "unknown" => true [Endpoint 0] 17:21:52.052 SERIAL » [ACK] (0x06) 17:21:52.053 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: true 17:21:52.056 SERIAL » 0x0109001312028002254715 (11 bytes) 17:21:52.057 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 71 └─[BatteryCCGet] 17:21:52.057 CNTRLR « [Node 019] received Binary Switch state: current value: true 17:21:52.058 CNTRLR [Node 019] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 17:21:52.089 SERIAL « [ACK] (0x06) 17:21:52.092 SERIAL « 0x0104011301e8 (6 bytes) 17:21:52.092 SERIAL » [ACK] (0x06) 17:21:52.094 DRIVER « [RES] [SendData] was sent: true 17:21:52.097 CNTRLR [Node 019] MultilevelSwitchCC: doing a partial interview... 17:21:52.097 CNTRLR » [Node 019] requesting current switch state... 17:21:52.253 SERIAL « 0x0107001347000013bf (9 bytes) 17:21:52.254 SERIAL » [ACK] (0x06) 17:21:52.255 DRIVER « [REQ] [SendData] callback id: 71 transmit status: OK 17:21:52.364 SERIAL « 0x0109000400120380036404 (11 bytes) 17:21:52.365 CNTRLR [Node 018] [~] [Battery] level: 100 => 100 [Endpoint 0] 17:21:52.365 CNTRLR [Node 018] [~] [Battery] isLow: false => false [Endpoint 0] 17:21:52.366 SERIAL » [ACK] (0x06) 17:21:52.369 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 17:21:52.373 SERIAL » 0x01090013130226022548bd (11 bytes) 17:21:52.374 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 72 └─[MultilevelSwitchCCGet] 17:21:52.375 CNTRLR « [Node 018] received response for battery information: level: 100 17:21:52.375 CNTRLR [Node 018] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:21:52.378 CNTRLR [Node 018] ZWavePlusCC: doing a partial interview... [Endpoint 1] 17:21:52.379 CNTRLR [Node 018] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 17:21:52.379 CNTRLR [Node 018] ThermostatModeCC: doing a partial interview... [Endpoint 1] 17:21:52.379 CNTRLR » [Node 018] querying current thermostat mode... [Endpoint 1] 17:21:52.385 SERIAL « [ACK] (0x06) 17:21:52.386 SERIAL « 0x0104011301e8 (6 bytes) 17:21:52.386 SERIAL » [ACK] (0x06) 17:21:52.387 DRIVER « [RES] [SendData] was sent: true 17:21:52.445 SERIAL « 0x0107001348000007a4 (9 bytes) 17:21:52.446 SERIAL » [ACK] (0x06) 17:21:52.446 DRIVER « [REQ] [SendData] callback id: 72 transmit status: OK 17:21:52.455 SERIAL « 0x01090004001303260363a4 (11 bytes) 17:21:52.456 CNTRLR [Node 019] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 0] 17:21:52.457 SERIAL » [ACK] (0x06) 17:21:52.458 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 99 17:21:52.461 SERIAL » 0x010d00131206600d000140022549b7 (15 bytes) 17:21:52.461 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 73 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 17:21:52.462 CNTRLR [Node 019] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 17:21:52.462 CNTRLR [Node 019] MultilevelSensorCC: doing a partial interview... 17:21:52.462 CNTRLR » [Node 019] querying current sensor reading... 17:21:52.466 SERIAL « [ACK] (0x06) 17:21:52.469 SERIAL « 0x0104011301e8 (6 bytes) 17:21:52.470 SERIAL » [ACK] (0x06) 17:21:52.471 DRIVER « [RES] [SendData] was sent: true 17:21:52.678 SERIAL « 0x0107001349000015b7 (9 bytes) 17:21:52.678 SERIAL » [ACK] (0x06) 17:21:52.679 DRIVER « [REQ] [SendData] callback id: 73 transmit status: OK 17:21:52.883 SERIAL « 0x010d0004001207600d0100400301cd (15 bytes) 17:21:52.885 CNTRLR [Node 018] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 17:21:52.885 SERIAL » [ACK] (0x06) 17:21:52.887 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 17:21:52.891 SERIAL » 0x0109001313023104254aae (11 bytes) 17:21:52.892 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 74 └─[MultilevelSensorCCGet] 17:21:52.892 CNTRLR « [Node 018] received current thermostat mode: Heat [Endpoint 1] 17:21:52.893 CNTRLR [Node 018] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 1] [internal] ue => true 17:21:52.924 SERIAL « [ACK] (0x06) 17:21:52.928 SERIAL « 0x0104011301e8 (6 bytes) 17:21:52.928 SERIAL » [ACK] (0x06) 17:21:52.930 DRIVER « [RES] [SendData] was sent: true 17:21:52.932 CNTRLR [Node 018] ThermostatSetpointCC: doing a partial interview... [Endpoint 1] 17:21:52.932 CNTRLR » [Node 018] querying current value of setpoint Heating... [Endpoint 1] 17:21:53.020 SERIAL « 0x010c00040003063105042209d831 (14 bytes) 17:21:53.021 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:21:53.022 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 121.6 => 252 [Endpoint 0] 17:21:53.022 SERIAL » [ACK] (0x06) 17:21:53.023 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 252 17:21:53.064 SERIAL « 0x010700134a000011b0 (9 bytes) 17:21:53.064 SERIAL » [ACK] (0x06) 17:21:53.065 DRIVER « [REQ] [SendData] callback id: 74 transmit status: OK 17:21:53.075 SERIAL « 0x010c0004001306310504220000f0 (14 bytes) 17:21:53.076 CNTRLR [Node 019] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:21:53.077 CNTRLR [Node 019] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 17:21:53.078 SERIAL » [ACK] (0x06) 17:21:53.079 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:21:53.085 SERIAL » 0x010e00131207600d0001430201254bb5 (16 bytes) 17:21:53.086 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 75 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 17:21:53.086 CNTRLR « [Node 019] received current sensor reading: sensor type: Power value: 0 W 17:21:53.087 CNTRLR [Node 019] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 17:21:53.142 SERIAL « [ACK] (0x06) 17:21:53.147 SERIAL « 0x0104011301e8 (6 bytes) 17:21:53.148 SERIAL » [ACK] (0x06) 17:21:53.150 DRIVER « [RES] [SendData] was sent: true 17:21:53.154 CNTRLR [Node 019] MeterCC: doing a partial interview... 17:21:53.155 CNTRLR » [Node 019] querying meter value (type = Electric, scale = kWh)... 17:21:54.727 CNTRLR [Node 020] Beginning interview - last completed stage: RestartFromCache 17:21:54.728 CNTRLR » [Node 020] pinging the node... 17:21:57.613 SERIAL « 0x010d0004001207600d0100400301cd (15 bytes) 17:21:57.614 CNTRLR [Node 018] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 17:21:57.615 SERIAL » [ACK] (0x06) 17:21:57.617 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 17:21:57.860 SERIAL « 0x010c00040003063105042208c32b (14 bytes) 17:21:57.862 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:21:57.863 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 252 => 224.3 [Endpoint 0] 17:21:57.863 SERIAL » [ACK] (0x06) 17:21:57.865 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 224.3 17:21:58.141 SERIAL « 0x010d0004101207600d0100400301dd (15 bytes) 17:21:58.143 CNTRLR [Node 018] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 17:21:58.144 SERIAL » [ACK] (0x06) 17:21:58.146 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 17:21:58.180 SERIAL « 0x010d0004101207600d0100400301dd (15 bytes) 17:21:58.182 CNTRLR [Node 018] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 17:21:58.183 SERIAL » [ACK] (0x06) 17:21:58.184 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 17:21:58.192 SERIAL « 0x010d0004101207600d0100400301dd (15 bytes) 17:21:58.197 CNTRLR [Node 018] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 17:21:58.198 SERIAL » [ACK] (0x06) 17:21:58.199 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 17:21:58.234 SERIAL « 0x010d0004101207600d0100400301dd (15 bytes) 17:21:58.235 CNTRLR [Node 018] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 17:21:58.236 SERIAL » [ACK] (0x06) 17:21:58.238 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 17:21:58.277 SERIAL « 0x010d0004101207600d0100400301dd (15 bytes) 17:21:58.278 CNTRLR [Node 018] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 17:21:58.279 SERIAL » [ACK] (0x06) 17:21:58.281 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 17:21:58.313 SERIAL « 0x010d0004101207600d0100400301dd (15 bytes) 17:21:58.314 CNTRLR [Node 018] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 17:21:58.315 SERIAL » [ACK] (0x06) 17:21:58.317 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 17:21:58.530 SERIAL « 0x010d0004101207600d0100400301dd (15 bytes) 17:21:58.532 CNTRLR [Node 018] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 17:21:58.533 SERIAL » [ACK] (0x06) 17:21:58.535 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 17:21:58.551 SERIAL « 0x010d0004101207600d0100400301dd (15 bytes) 17:21:58.553 CNTRLR [Node 018] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 17:21:58.554 SERIAL » [ACK] (0x06) 17:21:58.556 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 17:21:58.563 SERIAL « 0x010d0004101207600d0100400301dd (15 bytes) 17:21:58.565 CNTRLR [Node 018] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 17:21:58.566 SERIAL » [ACK] (0x06) 17:21:58.567 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 17:21:58.613 SERIAL « 0x010d0004101207600d0100400301dd (15 bytes) 17:21:58.614 CNTRLR [Node 018] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 17:21:58.615 SERIAL » [ACK] (0x06) 17:21:58.617 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 17:21:58.639 SERIAL « 0x010d0004101207600d0100400301dd (15 bytes) 17:21:58.640 CNTRLR [Node 018] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 17:21:58.641 SERIAL » [ACK] (0x06) 17:21:58.642 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 17:21:59.861 SERIAL « 0x010c000400030631050422036f8c (14 bytes) 17:21:59.862 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:21:59.863 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 224.3 => 87.9 [Endpoint 0] 17:21:59.863 SERIAL » [ACK] (0x06) 17:21:59.865 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 87.9 17:22:03.626 SERIAL « 0x010c000410030631050422089d65 (14 bytes) 17:22:03.627 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:22:03.628 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 87.9 => 220.5 [Endpoint 0] 17:22:03.629 SERIAL » [ACK] (0x06) 17:22:03.631 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 220.5 17:22:03.865 SERIAL « 0x010c000410030631050422089d65 (14 bytes) 17:22:03.867 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:22:03.868 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 220.5 => 220.5 [Endpoint 0] 17:22:03.869 SERIAL » [ACK] (0x06) 17:22:03.870 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 220.5 17:22:04.071 SERIAL « 0x010c000410030631050422089d65 (14 bytes) 17:22:04.072 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:22:04.073 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 220.5 => 220.5 [Endpoint 0] 17:22:04.074 SERIAL » [ACK] (0x06) 17:22:04.076 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 220.5 17:22:04.590 SERIAL « 0x010c000410030631050422089d65 (14 bytes) 17:22:04.590 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:22:04.591 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 220.5 => 220.5 [Endpoint 0] 17:22:04.591 SERIAL » [ACK] (0x06) 17:22:04.592 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 220.5 17:22:05.817 SERIAL « 0x010c000410030631050422089d65 (14 bytes) 17:22:05.818 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:22:05.819 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 220.5 => 220.5 [Endpoint 0] 17:22:05.819 SERIAL » [ACK] (0x06) 17:22:05.820 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 220.5 17:22:08.862 SERIAL « 0x010c00040003063105042203ae4d (14 bytes) 17:22:08.863 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:22:08.863 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 220.5 => 94.2 [Endpoint 0] 17:22:08.864 SERIAL » [ACK] (0x06) 17:22:08.865 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 94.2 17:22:11.906 SERIAL « 0x01090004001e03300300dc (11 bytes) 17:22:11.908 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:22:11.909 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:22:11.909 SERIAL » [ACK] (0x06) 17:22:11.914 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:22:11.966 SERIAL « 0x01090004001e03200100ce (11 bytes) 17:22:11.968 SERIAL » [ACK] (0x06) 17:22:11.969 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:22:11.972 CNTRLR [Node 030] treating BasicCC Set as a report 17:22:11.972 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:22:14.592 SERIAL « 0x010700134b000866ce (9 bytes) 17:22:14.593 SERIAL » [ACK] (0x06) 17:22:14.594 DRIVER « [REQ] [SendData] callback id: 75 transmit status: OK 17:22:14.689 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 17:22:14.691 SERIAL » [ACK] (0x06) 17:22:14.693 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  17:22:14.696 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 17:22:14.792 SERIAL « 0x0110000400120a600d01004303012200a05c (18 bytes) 17:22:14.794 CNTRLR [Node 018] [~] [Thermostat Setpoint] setpoint[1]: 16 => 16 [Endpoint 1] 17:22:14.795 CNTRLR [Node 018] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 17:22:14.796 SERIAL » [ACK] (0x06) 17:22:14.797 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 16 °C 17:22:14.804 SERIAL » 0x01080013140100254c98 (10 bytes) 17:22:14.804 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 76 └─[NoOperationCC] 17:22:14.805 CNTRLR « [Node 018] received current value of setpoint Heating: 16 °C [Endpoint 1] 17:22:14.806 CNTRLR [Node 018] [~] [Thermostat Setpoint] interviewComplete [Endpoint 1] [internal] : true => true 17:22:14.863 SERIAL « [ACK] (0x06) 17:22:14.868 SERIAL « 0x0104011301e8 (6 bytes) 17:22:14.869 SERIAL » [ACK] (0x06) 17:22:14.871 DRIVER « [RES] [SendData] was sent: true 17:22:14.873 CNTRLR [Node 018] NotificationCC: doing a partial interview... [Endpoint 1] 17:22:14.874 CNTRLR » [Node 018] querying notification status for Power Management... [Endpoint 1] 17:22:14.954 SERIAL « 0x010700134c00000fa8 (9 bytes) 17:22:14.955 SERIAL » [ACK] (0x06) 17:22:14.955 DRIVER « [REQ] [SendData] callback id: 76 transmit status: OK 17:22:14.959 SERIAL » 0x010a00131303320100254dad (12 bytes) 17:22:14.960 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 77 └─[MeterCCGet] duration: kWh 17:22:14.961 CNTRLR « [Node 020] ping successful 17:22:14.962 CNTRLR [Node 020] ManufacturerSpecificCC: doing a partial interview... 17:22:14.962 CNTRLR [Node 020] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:22:14.962 CNTRLR [Node 020] VersionCC: doing a partial interview... 17:22:14.963 CNTRLR [Node 020] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:22:14.963 CNTRLR [Node 020] trying to load device config 17:22:14.965 SERIAL « [ACK] (0x06) 17:22:14.976 CNTRLR [Node 020] device config loaded 17:22:14.977 CNTRLR [Node 020] WakeUpCC: doing a complete interview... 17:22:14.977 CNTRLR » [Node 020] retrieving wakeup interval from the device... 17:22:14.980 SERIAL « 0x0104011301e8 (6 bytes) 17:22:14.980 SERIAL » [ACK] (0x06) 17:22:14.981 DRIVER « [RES] [SendData] was sent: true 17:22:14.985 SERIAL « 0x010700134d000002a4 (9 bytes) 17:22:14.986 SERIAL » [ACK] (0x06) 17:22:14.986 DRIVER « [REQ] [SendData] callback id: 77 transmit status: OK 17:22:14.998 SERIAL « 0x0110000400130a320221440000010c0000aa (18 bytes) 17:22:14.999 CNTRLR [Node 019] [~] [Meter] value[65537]: 2.68 => 2.68 [Endpoint 0] 17:22:15.000 CNTRLR [Node 019] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 17:22:15.000 SERIAL » [ACK] (0x06) 17:22:15.002 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 2.68 time delta: 0 seconds 17:22:15.005 SERIAL » 0x0109001314028405254e19 (11 bytes) 17:22:15.006 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 78 └─[WakeUpCCIntervalGet] 17:22:15.006 CNTRLR » [Node 019] querying meter value (type = Electric, scale = W)... 17:22:15.016 SERIAL « [ACK] (0x06) 17:22:15.017 SERIAL « 0x0104011301e8 (6 bytes) 17:22:15.017 SERIAL » [ACK] (0x06) 17:22:15.018 DRIVER « [RES] [SendData] was sent: true 17:22:15.111 SERIAL « 0x010700134e00000bae (9 bytes) 17:22:15.111 SERIAL » [ACK] (0x06) 17:22:15.112 DRIVER « [REQ] [SendData] callback id: 78 transmit status: OK 17:22:16.715 CNTRLR [Node 020] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 17:22:16.862 SERIAL « 0x010c00040003063105042208cd25 (14 bytes) 17:22:16.863 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:22:16.865 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 94.2 => 225.3 [Endpoint 0] 17:22:16.866 SERIAL » [ACK] (0x06) 17:22:16.868 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 225.3 17:22:17.222 SERIAL » 0x0109001314028405254e19 (11 bytes) 17:22:17.223 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 78 └─[WakeUpCCIntervalGet] 17:22:17.225 SERIAL « [ACK] (0x06) 17:22:17.231 SERIAL « 0x0104011301e8 (6 bytes) 17:22:17.232 SERIAL » [ACK] (0x06) 17:22:17.236 DRIVER « [RES] [SendData] was sent: true 17:22:17.328 SERIAL « 0x010700134e00000aaf (9 bytes) 17:22:17.329 SERIAL » [ACK] (0x06) 17:22:17.329 DRIVER « [REQ] [SendData] callback id: 78 transmit status: OK 17:22:17.862 SERIAL « 0x010c000400030631050422049074 (14 bytes) 17:22:17.864 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:22:17.865 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 225.3 => 116.8 [Endpoint 0] 17:22:17.865 SERIAL » [ACK] (0x06) 17:22:17.867 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 116.8 17:22:18.933 CNTRLR [Node 020] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 17:22:19.439 SERIAL » 0x0109001314028405254e19 (11 bytes) 17:22:19.440 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 78 └─[WakeUpCCIntervalGet] 17:22:19.442 SERIAL « [ACK] (0x06) 17:22:19.449 SERIAL « 0x0104011301e8 (6 bytes) 17:22:19.450 SERIAL » [ACK] (0x06) 17:22:19.450 DRIVER « [RES] [SendData] was sent: true 17:22:19.545 SERIAL « 0x010700134e00000aaf (9 bytes) 17:22:19.545 SERIAL » [ACK] (0x06) 17:22:19.546 DRIVER « [REQ] [SendData] callback id: 78 transmit status: OK 17:22:20.862 SERIAL « 0x010c000400030631050422077b9c (14 bytes) 17:22:20.863 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:22:20.864 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 116.8 => 191.5 [Endpoint 0] 17:22:20.864 SERIAL » [ACK] (0x06) 17:22:20.865 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 191.5 17:22:21.159 SERIAL » 0x011000131209600d00017104000800254f9c (18 bytes) 17:22:21.160 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 79 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: Power Management 17:22:21.161 CNTRLR [Node 020] Interview attempt 2/5 failed, retrying in 10000 ms... 17:22:21.162 SERIAL « [ACK] (0x06) 17:22:21.169 SERIAL « 0x0104011301e8 (6 bytes) 17:22:21.170 SERIAL » [ACK] (0x06) 17:22:21.170 DRIVER « [RES] [SendData] was sent: true 17:22:22.641 SERIAL « 0x010700134f00009430 (9 bytes) 17:22:22.642 SERIAL » [ACK] (0x06) 17:22:22.643 DRIVER « [REQ] [SendData] callback id: 79 transmit status: OK 17:22:22.819 SERIAL « 0x01090004001b03300300d9 (11 bytes) 17:22:22.820 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:22:22.821 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:22:22.822 SERIAL » [ACK] (0x06) 17:22:22.824 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:22:22.873 SERIAL « 0x01090004001b03200100cb (11 bytes) 17:22:22.874 SERIAL » [ACK] (0x06) 17:22:22.875 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:22:22.877 CNTRLR [Node 027] treating BasicCC Set as a report 17:22:22.877 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:22:22.924 SERIAL « 0x0113000400120d600d01007105000000ff08fe00e6 (21 bytes) 17:22:22.925 SERIAL » [ACK] (0x06) 17:22:22.926 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 17:22:22.932 SERIAL » 0x010a001313033201102550a0 (12 bytes) 17:22:22.933 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 80 └─[MeterCCGet] duration: W 17:22:22.934 CNTRLR [Node 018] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 1] 54 17:22:22.935 CNTRLR » [Node 018] querying notification status for System... [Endpoint 1] 17:22:22.941 SERIAL « [ACK] (0x06) 17:22:22.946 SERIAL « 0x0104011301e8 (6 bytes) 17:22:22.947 SERIAL » [ACK] (0x06) 17:22:22.949 DRIVER « [RES] [SendData] was sent: true 17:22:23.015 SERIAL « 0x0107001350000008b3 (9 bytes) 17:22:23.016 SERIAL » [ACK] (0x06) 17:22:23.017 DRIVER « [REQ] [SendData] callback id: 80 transmit status: OK 17:22:23.027 SERIAL « 0x010e00040013083202213200000000cd (16 bytes) 17:22:23.028 CNTRLR [Node 019] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 17:22:23.029 CNTRLR [Node 019] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 17:22:23.030 SERIAL » [ACK] (0x06) 17:22:23.031 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 17:22:23.036 SERIAL » 0x011000131209600d00017104000900255183 (18 bytes) 17:22:23.036 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 81 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: System 17:22:23.037 CNTRLR [Node 019] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 17:22:23.074 SERIAL « [ACK] (0x06) 17:22:23.075 SERIAL « 0x0104011301e8 (6 bytes) 17:22:23.075 SERIAL » [ACK] (0x06) 17:22:23.077 DRIVER « [RES] [SendData] was sent: true 17:22:23.079 CNTRLR [Node 019] ConfigurationCC: Loading configuration parameters from device confi g 17:22:23.084 CNTRLR [Node 019] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:22:23.085 CNTRLR [Node 019] [Configuration] 1: metadata updated 17:22:23.086 CNTRLR [Node 019] [Configuration] 2: metadata updated 17:22:23.087 CNTRLR [Node 019] [Configuration] 3: metadata updated 17:22:23.088 CNTRLR [Node 019] [Configuration] 10: metadata updated 17:22:23.089 CNTRLR [Node 019] [Configuration] 12: metadata updated 17:22:23.090 CNTRLR [Node 019] [Configuration] 13: metadata updated 17:22:23.091 CNTRLR [Node 019] [Configuration] 14: metadata updated 17:22:23.092 CNTRLR [Node 019] [Configuration] 17: metadata updated 17:22:23.093 CNTRLR [Node 019] [Configuration] 18: metadata updated 17:22:23.094 CNTRLR [Node 019] [Configuration] 22: metadata updated 17:22:23.095 CNTRLR [Node 019] [Configuration] 29: metadata updated 17:22:23.096 CNTRLR [Node 019] [Configuration] 30: metadata updated 17:22:23.097 CNTRLR [Node 019] [Configuration] 31: metadata updated 17:22:23.098 CNTRLR [Node 019] [Configuration] 32: metadata updated 17:22:23.099 CNTRLR [Node 019] [Configuration] 33: metadata updated 17:22:23.100 CNTRLR [Node 019] [Configuration] 35: metadata updated 17:22:23.101 CNTRLR [Node 019] [Configuration] 40: metadata updated 17:22:23.102 CNTRLR [Node 019] [Configuration] 42: metadata updated 17:22:23.103 CNTRLR [Node 019] [Configuration] 43: metadata updated 17:22:23.104 CNTRLR [Node 019] [Configuration] 44: metadata updated 17:22:23.105 CNTRLR [Node 019] [Configuration] 50: metadata updated 17:22:23.106 CNTRLR [Node 019] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:22:23.106 CNTRLR » [Node 019] querying parameter #1 value... 17:22:23.116 SERIAL « 0x0107001351000007bd (9 bytes) 17:22:23.116 SERIAL » [ACK] (0x06) 17:22:23.117 DRIVER « [REQ] [SendData] callback id: 81 transmit status: OK 17:22:23.212 SERIAL « 0x0113000400120d600d01007105000000ff09fe00e7 (21 bytes) 17:22:23.213 SERIAL » [ACK] (0x06) 17:22:23.214 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: System notification status: 255 notification event: Unknown (0xfe) 17:22:23.220 SERIAL » 0x010a001313037005012552f5 (12 bytes) 17:22:23.221 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 82 └─[ConfigurationCCGet] parameter #: 1 17:22:23.222 CNTRLR [Node 018] [~] [Notification] System[unknown]: 254 => 254 [Endpoint 1] 17:22:23.222 CNTRLR [Node 018] [~] [Notification] interviewComplete: true [Endpoint 1] [internal] => true 17:22:23.223 CNTRLR [Node 018] ProtectionCC: doing a partial interview... 17:22:23.223 CNTRLR » [Node 018] querying protection status... 17:22:23.227 SERIAL « [ACK] (0x06) 17:22:23.229 SERIAL « 0x0104011301e8 (6 bytes) 17:22:23.229 SERIAL » [ACK] (0x06) 17:22:23.229 DRIVER « [RES] [SendData] was sent: true 17:22:23.285 SERIAL « 0x0107001352000006bf (9 bytes) 17:22:23.285 SERIAL » [ACK] (0x06) 17:22:23.286 DRIVER « [REQ] [SendData] callback id: 82 transmit status: OK 17:22:23.644 SERIAL « 0x01080004001502840767 (10 bytes) 17:22:23.644 SERIAL » [ACK] (0x06) 17:22:23.645 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:22:23.646 CNTRLR « [Node 021] received wakeup notification 17:22:23.647 CNTRLR [Node 021] The node is awake. 17:22:23.648 CNTRLR [Node 021] The node is ready to be used 17:22:24.890 CNTRLR [Node 019] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 17:22:25.394 SERIAL » 0x010a001313037005012552f5 (12 bytes) 17:22:25.394 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 82 └─[ConfigurationCCGet] parameter #: 1 17:22:25.396 SERIAL « [ACK] (0x06) 17:22:25.402 SERIAL « 0x0104011301e8 (6 bytes) 17:22:25.402 SERIAL » [ACK] (0x06) 17:22:25.403 DRIVER « [RES] [SendData] was sent: true 17:22:25.420 SERIAL « 0x0107001352000003ba (9 bytes) 17:22:25.420 SERIAL » [ACK] (0x06) 17:22:25.420 DRIVER « [REQ] [SendData] callback id: 82 transmit status: OK 17:22:27.023 CNTRLR [Node 019] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 17:22:27.527 SERIAL » 0x010a001313037005012552f5 (12 bytes) 17:22:27.527 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 82 └─[ConfigurationCCGet] parameter #: 1 17:22:27.529 SERIAL « [ACK] (0x06) 17:22:27.535 SERIAL « 0x0104011301e8 (6 bytes) 17:22:27.536 SERIAL » [ACK] (0x06) 17:22:27.536 DRIVER « [RES] [SendData] was sent: true 17:22:27.553 SERIAL « 0x0107001352000002bb (9 bytes) 17:22:27.553 SERIAL » [ACK] (0x06) 17:22:27.553 DRIVER « [REQ] [SendData] callback id: 82 transmit status: OK 17:22:29.162 SERIAL » 0x010d00131206600d00017502255398 (15 bytes) 17:22:29.163 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 83 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 17:22:29.164 CNTRLR « [Node 019] received no value for parameter #1 17:22:29.165 CNTRLR » [Node 019] querying parameter #2 value... 17:22:29.170 SERIAL « [ACK] (0x06) 17:22:29.172 SERIAL « 0x0104011301e8 (6 bytes) 17:22:29.173 SERIAL » [ACK] (0x06) 17:22:29.174 DRIVER « [RES] [SendData] was sent: true 17:22:30.661 SERIAL « 0x01070013530000962e (9 bytes) 17:22:30.662 SERIAL » [ACK] (0x06) 17:22:30.662 DRIVER « [REQ] [SendData] callback id: 83 transmit status: OK 17:22:30.777 SERIAL « 0x010d0004001207600d0100750300f9 (15 bytes) 17:22:30.779 CNTRLR [Node 018] [~] [Protection] local: 0 => 0 [Endpoint 1] 17:22:30.780 SERIAL » [ACK] (0x06) 17:22:30.782 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ProtectionCCReport] local: Unprotected 17:22:30.789 SERIAL » 0x010a001313037005022554f0 (12 bytes) 17:22:30.790 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 84 └─[ConfigurationCCGet] parameter #: 2 17:22:30.791 CNTRLR « [Node 018] received protection status: local: Unprotected 17:22:30.792 CNTRLR [Node 018] [~] [Protection] interviewComplete: true => [Endpoint 1] [internal] true 17:22:30.891 SERIAL « [ACK] (0x06) 17:22:30.894 SERIAL « 0x0104011301e8 (6 bytes) 17:22:30.894 SERIAL » [ACK] (0x06) 17:22:30.895 DRIVER « [RES] [SendData] was sent: true 17:22:30.897 SERIAL « 0x0107001354000007b8 (9 bytes) 17:22:30.898 SERIAL » [ACK] (0x06) 17:22:30.899 CNTRLR [Node 018] BatteryCC: doing a partial interview... [Endpoint 1] 17:22:30.899 CNTRLR » [Node 018] querying battery status... [Endpoint 1] 17:22:30.901 DRIVER « [REQ] [SendData] callback id: 84 transmit status: OK 17:22:31.161 CNTRLR [Node 020] Beginning interview - last completed stage: RestartFromCache 17:22:31.161 CNTRLR » [Node 020] pinging the node... 17:22:32.505 CNTRLR [Node 019] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 17:22:33.011 SERIAL » 0x010a001313037005022554f0 (12 bytes) 17:22:33.012 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 84 └─[ConfigurationCCGet] parameter #: 2 17:22:33.014 SERIAL « [ACK] (0x06) 17:22:33.020 SERIAL « 0x0104011301e8 (6 bytes) 17:22:33.021 SERIAL » [ACK] (0x06) 17:22:33.021 DRIVER « [RES] [SendData] was sent: true 17:22:33.038 SERIAL « 0x0107001354000002bd (9 bytes) 17:22:33.038 SERIAL » [ACK] (0x06) 17:22:33.039 DRIVER « [REQ] [SendData] callback id: 84 transmit status: OK 17:22:33.648 DRIVER The awake timeout for node 21 has elapsed. Assuming it is asleep. 17:22:33.649 CNTRLR [Node 021] The node is now asleep. 17:22:33.650 CNTRLR [Node 021] ping failed: The node is asleep 17:22:33.652 CNTRLR [Node 021] ManufacturerSpecificCC: doing a partial interview... 17:22:33.652 CNTRLR [Node 021] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:22:33.703 CNTRLR [Node 021] VersionCC: doing a partial interview... 17:22:33.703 CNTRLR [Node 021] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:22:33.704 CNTRLR [Node 021] trying to load device config 17:22:33.718 CNTRLR [Node 021] device config loaded 17:22:33.719 CNTRLR [Node 021] BatteryCC: doing a partial interview... 17:22:33.719 CNTRLR » [Node 021] querying battery status... 17:22:34.642 CNTRLR [Node 019] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 17:22:35.148 SERIAL » 0x010a001313037005022554f0 (12 bytes) 17:22:35.149 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 84 └─[ConfigurationCCGet] parameter #: 2 17:22:35.151 SERIAL « [ACK] (0x06) 17:22:35.157 SERIAL « 0x0104011301e8 (6 bytes) 17:22:35.158 SERIAL » [ACK] (0x06) 17:22:35.159 DRIVER « [RES] [SendData] was sent: true 17:22:35.175 SERIAL « 0x0107001354000002bd (9 bytes) 17:22:35.175 SERIAL » [ACK] (0x06) 17:22:35.176 DRIVER « [REQ] [SendData] callback id: 84 transmit status: OK 17:22:36.805 SERIAL » 0x01080013160100255583 (10 bytes) 17:22:36.806 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 85 └─[NoOperationCC] 17:22:36.808 CNTRLR « [Node 019] received no value for parameter #2 17:22:36.808 CNTRLR » [Node 019] querying parameter #3 value... 17:22:36.814 SERIAL « [ACK] (0x06) 17:22:36.816 SERIAL « 0x0104011301e8 (6 bytes) 17:22:36.817 SERIAL » [ACK] (0x06) 17:22:36.818 DRIVER « [RES] [SendData] was sent: true 17:22:38.065 SERIAL « 0x010700135500007dc3 (9 bytes) 17:22:38.066 SERIAL » [ACK] (0x06) 17:22:38.067 DRIVER « [REQ] [SendData] callback id: 85 transmit status: OK 17:22:38.075 SERIAL » 0x01080013170100255681 (10 bytes) 17:22:38.076 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 86 └─[NoOperationCC] 17:22:38.077 CNTRLR « [Node 022] ping successful 17:22:38.089 CNTRLR [Node 022] ManufacturerSpecificCC: doing a partial interview... 17:22:38.090 CNTRLR [Node 022] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:22:38.140 SERIAL « [ACK] (0x06) 17:22:38.141 SERIAL « 0x0104011301e8 (6 bytes) 17:22:38.142 SERIAL » [ACK] (0x06) 17:22:38.147 DRIVER « [RES] [SendData] was sent: true 17:22:38.149 SERIAL « 0x0107001356000002bf (9 bytes) 17:22:38.150 SERIAL » [ACK] (0x06) 17:22:38.151 CNTRLR [Node 022] VersionCC: doing a partial interview... 17:22:38.151 CNTRLR [Node 022] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:22:38.151 CNTRLR [Node 022] trying to load device config 17:22:38.166 DRIVER « [REQ] [SendData] callback id: 86 transmit status: OK 17:22:38.172 SERIAL » 0x0108001318010025578f (10 bytes) 17:22:38.173 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 87 └─[NoOperationCC] 17:22:38.174 CNTRLR « [Node 023] ping successful 17:22:38.175 CNTRLR [Node 023] ManufacturerSpecificCC: doing a partial interview... 17:22:38.175 CNTRLR [Node 023] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:22:38.176 CNTRLR [Node 023] VersionCC: doing a partial interview... 17:22:38.176 CNTRLR [Node 023] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:22:38.177 CNTRLR [Node 023] trying to load device config 17:22:38.180 SERIAL « [ACK] (0x06) 17:22:38.182 SERIAL « 0x0104011301e8 (6 bytes) 17:22:38.182 SERIAL » [ACK] (0x06) 17:22:38.183 DRIVER « [RES] [SendData] was sent: true 17:22:38.189 CNTRLR [Node 022] device config loaded 17:22:38.190 CNTRLR [Node 022] ZWavePlusCC: doing a partial interview... 17:22:38.190 CNTRLR [Node 022] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 17:22:38.191 CNTRLR » [Node 022] querying device endpoint information... 17:22:38.210 CNTRLR [Node 023] device config loaded 17:22:38.210 CNTRLR » [Node 023] querying device endpoint information... 17:22:38.213 SERIAL « 0x0107001357000003bf (9 bytes) 17:22:38.213 SERIAL » [ACK] (0x06) 17:22:38.214 DRIVER « [REQ] [SendData] callback id: 87 transmit status: OK 17:22:38.218 SERIAL » 0x01080013190100255881 (10 bytes) 17:22:38.219 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 88 └─[NoOperationCC] 17:22:38.219 CNTRLR « [Node 024] ping successful 17:22:38.221 CNTRLR [Node 024] ManufacturerSpecificCC: doing a partial interview... 17:22:38.221 CNTRLR [Node 024] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:22:38.221 CNTRLR [Node 024] VersionCC: doing a partial interview... 17:22:38.222 CNTRLR [Node 024] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:22:38.222 CNTRLR [Node 024] trying to load device config 17:22:38.224 SERIAL « [ACK] (0x06) 17:22:38.241 CNTRLR [Node 024] device config loaded 17:22:38.242 CNTRLR [Node 024] ZWavePlusCC: doing a partial interview... 17:22:38.242 CNTRLR [Node 024] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 17:22:38.243 CNTRLR » [Node 024] querying device endpoint information... 17:22:38.245 SERIAL « 0x0104011301e8 (6 bytes) 17:22:38.246 SERIAL » [ACK] (0x06) 17:22:38.246 DRIVER « [RES] [SendData] was sent: true 17:22:38.248 SERIAL « 0x0107001358000002b1 (9 bytes) 17:22:38.248 SERIAL » [ACK] (0x06) 17:22:38.248 DRIVER « [REQ] [SendData] callback id: 88 transmit status: OK 17:22:38.252 SERIAL » 0x010800131a0100255983 (10 bytes) 17:22:38.253 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 89 └─[NoOperationCC] 17:22:38.253 CNTRLR « [Node 025] ping successful 17:22:38.254 CNTRLR [Node 025] ManufacturerSpecificCC: doing a partial interview... 17:22:38.255 CNTRLR [Node 025] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:22:38.255 CNTRLR [Node 025] VersionCC: doing a partial interview... 17:22:38.255 CNTRLR [Node 025] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:22:38.255 CNTRLR [Node 025] trying to load device config 17:22:38.258 SERIAL « [ACK] (0x06) 17:22:38.272 CNTRLR [Node 025] device config loaded 17:22:38.273 CNTRLR » [Node 025] querying device endpoint information... 17:22:38.275 SERIAL « 0x0104011301e8 (6 bytes) 17:22:38.275 SERIAL » [ACK] (0x06) 17:22:38.276 DRIVER « [RES] [SendData] was sent: true 17:22:38.298 SERIAL « 0x0107001359000004b6 (9 bytes) 17:22:38.299 SERIAL » [ACK] (0x06) 17:22:38.299 DRIVER « [REQ] [SendData] callback id: 89 transmit status: OK 17:22:38.304 SERIAL » 0x010a00131303700503255aff (12 bytes) 17:22:38.304 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 90 └─[ConfigurationCCGet] parameter #: 3 17:22:38.305 CNTRLR « [Node 026] ping successful 17:22:38.306 CNTRLR [Node 026] ManufacturerSpecificCC: doing a partial interview... 17:22:38.306 CNTRLR [Node 026] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:22:38.339 SERIAL « [ACK] (0x06) 17:22:38.342 SERIAL « 0x0104011301e8 (6 bytes) 17:22:38.342 SERIAL » [ACK] (0x06) 17:22:38.343 DRIVER « [RES] [SendData] was sent: true 17:22:38.345 SERIAL « 0x010700135a000003b2 (9 bytes) 17:22:38.345 SERIAL » [ACK] (0x06) 17:22:38.346 CNTRLR [Node 026] VersionCC: doing a partial interview... 17:22:38.346 CNTRLR [Node 026] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:22:38.346 CNTRLR [Node 026] trying to load device config 17:22:38.348 DRIVER « [REQ] [SendData] callback id: 90 transmit status: OK 17:22:38.350 SERIAL « 0x010b0004001305700603010092 (13 bytes) 17:22:38.355 CNTRLR [Node 019] [~] [Configuration] 3: 0 => 0 17:22:38.357 SERIAL » [ACK] (0x06) 17:22:38.358 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 17:22:38.361 SERIAL » 0x0109001316026007255be8 (11 bytes) 17:22:38.361 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 91 └─[MultiChannelCCEndPointGet] 17:22:38.362 CNTRLR « [Node 019] parameter #3 has value: 0 17:22:38.362 CNTRLR » [Node 019] querying parameter #10 value... 17:22:38.376 CNTRLR [Node 026] device config loaded 17:22:38.376 CNTRLR [Node 026] AssociationCC: doing a partial interview... 17:22:38.376 CNTRLR [Node 026] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:22:38.377 CNTRLR [Node 026] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:22:38.377 CNTRLR [Node 026] BinarySwitchCC: doing a partial interview... 17:22:38.377 CNTRLR » [Node 026] querying Binary Switch state... 17:22:38.379 SERIAL « [ACK] (0x06) 17:22:38.381 SERIAL « 0x0104011301e8 (6 bytes) 17:22:38.381 SERIAL » [ACK] (0x06) 17:22:38.382 DRIVER « [RES] [SendData] was sent: true 17:22:38.389 SERIAL « 0x010700135b000003b3 (9 bytes) 17:22:38.390 SERIAL » [ACK] (0x06) 17:22:38.390 DRIVER « [REQ] [SendData] callback id: 91 transmit status: OK 17:22:38.409 SERIAL « 0x010b0004001605600800020089 (13 bytes) 17:22:38.410 CNTRLR [Node 022] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 17:22:38.410 CNTRLR [Node 022] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 17:22:38.410 CNTRLR [Node 022] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 17:22:38.410 CNTRLR [Node 022] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 17:22:38.411 SERIAL » [ACK] (0x06) 17:22:38.411 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 17:22:38.417 SERIAL » 0x0109001317026007255cee (11 bytes) 17:22:38.417 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 92 └─[MultiChannelCCEndPointGet] 17:22:38.418 CNTRLR [Node 022] The node is alive. 17:22:38.419 CNTRLR [Node 022] The node is ready to be used 17:22:38.420 CNTRLR « [Node 022] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 17:22:38.420 CNTRLR » [Node 022] querying all endpoints... 17:22:38.424 SERIAL « [ACK] (0x06) 17:22:38.427 SERIAL « 0x0104011301e8 (6 bytes) 17:22:38.427 SERIAL » [ACK] (0x06) 17:22:38.428 DRIVER « [RES] [SendData] was sent: true 17:22:38.445 SERIAL « 0x010700135c000002b5 (9 bytes) 17:22:38.445 SERIAL » [ACK] (0x06) 17:22:38.445 DRIVER « [REQ] [SendData] callback id: 92 transmit status: OK 17:22:38.455 SERIAL « 0x010a000400170460084002c8 (12 bytes) 17:22:38.455 CNTRLR [Node 023] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 17:22:38.456 CNTRLR [Node 023] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 17:22:38.456 CNTRLR [Node 023] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 17:22:38.456 SERIAL » [ACK] (0x06) 17:22:38.457 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: true 17:22:38.460 SERIAL » 0x0109001318026007255de0 (11 bytes) 17:22:38.460 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 93 └─[MultiChannelCCEndPointGet] 17:22:38.461 CNTRLR [Node 023] The node is alive. 17:22:38.461 CNTRLR [Node 023] The node is ready to be used 17:22:38.462 CNTRLR « [Node 023] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: true 17:22:38.463 CNTRLR [Node 023] does not support EndPointFind, assuming that endpoints are sequenti al 17:22:38.463 CNTRLR » [Node 023] querying capabilities for endpoint #1... 17:22:38.467 SERIAL « [ACK] (0x06) 17:22:38.470 SERIAL « 0x0104011301e8 (6 bytes) 17:22:38.470 SERIAL » [ACK] (0x06) 17:22:38.471 DRIVER « [RES] [SendData] was sent: true 17:22:39.195 SERIAL « 0x010700135d000003b5 (9 bytes) 17:22:39.195 SERIAL » [ACK] (0x06) 17:22:39.199 DRIVER « [REQ] [SendData] callback id: 93 transmit status: OK 17:22:39.202 SERIAL « 0x010b00040018056008400200c7 (13 bytes) 17:22:39.203 CNTRLR [Node 024] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 17:22:39.204 CNTRLR [Node 024] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 17:22:39.204 CNTRLR [Node 024] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 17:22:39.204 CNTRLR [Node 024] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 17:22:39.205 SERIAL » [ACK] (0x06) 17:22:39.206 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: true endpoint count (aggregated): 0 17:22:39.209 SERIAL » 0x0109001319026007255ee2 (11 bytes) 17:22:39.209 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 94 └─[MultiChannelCCEndPointGet] 17:22:39.210 CNTRLR [Node 024] The node is alive. 17:22:39.210 CNTRLR [Node 024] The node is ready to be used 17:22:39.212 CNTRLR « [Node 024] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: true endpoint count (aggregated): 0 17:22:39.212 CNTRLR » [Node 024] querying all endpoints... 17:22:39.387 SERIAL « 0x010c0004000306310504220a26cc (14 bytes) 17:22:39.388 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:22:39.389 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 191.5 => 259.8 [Endpoint 0] 17:22:39.390 SERIAL » [ACK] (0x06) 17:22:39.390 SERIAL « [CAN] (0x18) 17:22:39.391 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 17:22:39.393 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 259.8 17:22:40.003 SERIAL » 0x0109001319026007255ee2 (11 bytes) 17:22:40.004 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 94 └─[MultiChannelCCEndPointGet] 17:22:40.006 SERIAL « 0x010c00040003063105042205ed08 (14 bytes) 17:22:40.007 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:22:40.008 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 259.8 => 151.7 [Endpoint 0] 17:22:40.009 SERIAL » [ACK] (0x06) 17:22:40.009 SERIAL « [CAN] (0x18) 17:22:40.010 CNTRLR No response from controller after 2/3 attempts. Scheduling next try in 1100 ms . 17:22:40.013 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 151.7 17:22:40.864 SERIAL « 0x010c00040003063105042204aa4e (14 bytes) 17:22:40.865 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:22:40.866 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 151.7 => 119.4 [Endpoint 0] 17:22:40.867 SERIAL » [ACK] (0x06) 17:22:40.868 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 119.4 17:22:41.111 SERIAL » 0x0109001319026007255ee2 (11 bytes) 17:22:41.112 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 94 └─[MultiChannelCCEndPointGet] 17:22:41.113 SERIAL « [ACK] (0x06) 17:22:41.120 SERIAL « 0x0104011301e8 (6 bytes) 17:22:41.120 SERIAL » [ACK] (0x06) 17:22:41.120 DRIVER « [RES] [SendData] was sent: true 17:22:41.137 SERIAL « 0x010700135e000002b7 (9 bytes) 17:22:41.137 SERIAL » [ACK] (0x06) 17:22:41.143 DRIVER « [REQ] [SendData] callback id: 94 transmit status: OK 17:22:41.147 SERIAL « 0x010a000400190460084002c6 (12 bytes) 17:22:41.148 CNTRLR [Node 025] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 17:22:41.149 CNTRLR [Node 025] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 17:22:41.150 CNTRLR [Node 025] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 17:22:41.150 SERIAL » [ACK] (0x06) 17:22:41.151 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: true 17:22:41.158 SERIAL » 0x010a0013130370050a255ff3 (12 bytes) 17:22:41.159 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 95 └─[ConfigurationCCGet] parameter #: 10 17:22:41.160 CNTRLR [Node 025] The node is alive. 17:22:41.161 CNTRLR [Node 025] The node is ready to be used 17:22:41.162 CNTRLR « [Node 025] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: true 17:22:41.162 CNTRLR [Node 025] does not support EndPointFind, assuming that endpoints are sequenti al 17:22:41.163 CNTRLR » [Node 025] querying capabilities for endpoint #1... 17:22:41.168 SERIAL « [ACK] (0x06) 17:22:41.170 SERIAL « 0x0104011301e8 (6 bytes) 17:22:41.171 SERIAL » [ACK] (0x06) 17:22:41.172 DRIVER « [RES] [SendData] was sent: true 17:22:41.187 SERIAL « 0x010700135f000002b6 (9 bytes) 17:22:41.188 SERIAL » [ACK] (0x06) 17:22:41.188 DRIVER « [REQ] [SendData] callback id: 95 transmit status: OK 17:22:41.382 SERIAL « 0x010b000400130570060a01019a (13 bytes) 17:22:41.389 CNTRLR [Node 019] [~] [Configuration] 10: 1 => 1 17:22:41.390 SERIAL » [ACK] (0x06) 17:22:41.391 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 1 17:22:41.394 SERIAL » 0x010900131a02250225609f (11 bytes) 17:22:41.395 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 96 └─[BinarySwitchCCGet] 17:22:41.395 CNTRLR « [Node 019] parameter #10 has value: 1 17:22:41.395 CNTRLR » [Node 019] querying parameter #12 value... 17:22:41.400 SERIAL « [ACK] (0x06) 17:22:41.403 SERIAL « 0x0104011301e8 (6 bytes) 17:22:41.404 SERIAL » [ACK] (0x06) 17:22:41.405 DRIVER « [RES] [SendData] was sent: true 17:22:41.440 SERIAL « 0x01070013600000058e (9 bytes) 17:22:41.441 SERIAL » [ACK] (0x06) 17:22:41.441 DRIVER « [REQ] [SendData] callback id: 96 transmit status: OK 17:22:41.487 SERIAL « 0x01090004001a032503ff32 (11 bytes) 17:22:41.488 CNTRLR [Node 026] [~] [Binary Switch] currentValue: "unknown" => true [Endpoint 0] 17:22:41.489 SERIAL » [ACK] (0x06) 17:22:41.490 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: true 17:22:41.493 SERIAL » 0x010b00131604600bffff2561da (13 bytes) 17:22:41.493 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 97 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 17:22:41.494 CNTRLR [Node 026] The node is alive. 17:22:41.495 CNTRLR [Node 026] The node is ready to be used 17:22:41.498 CNTRLR « [Node 026] received Binary Switch state: current value: true 17:22:41.499 CNTRLR [Node 026] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 17:22:41.529 SERIAL « [ACK] (0x06) 17:22:41.534 SERIAL « 0x0104011301e8 (6 bytes) 17:22:41.535 SERIAL » [ACK] (0x06) 17:22:41.538 DRIVER « [RES] [SendData] was sent: true 17:22:41.541 CNTRLR [Node 026] MultilevelSwitchCC: doing a partial interview... 17:22:41.541 CNTRLR » [Node 026] requesting current switch state... 17:22:42.810 SERIAL « 0x01070013610000840e (9 bytes) 17:22:42.811 SERIAL » [ACK] (0x06) 17:22:42.811 DRIVER « [REQ] [SendData] callback id: 97 transmit status: OK 17:22:42.830 SERIAL « 0x010d0004001607600c00ffff010288 (15 bytes) 17:22:42.831 SERIAL » [ACK] (0x06) 17:22:42.832 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 17:22:42.837 SERIAL » 0x010a001317036009012562dd (12 bytes) 17:22:42.837 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 98 └─[MultiChannelCCCapabilityGet] endpoint: 1 17:22:42.838 CNTRLR « [Node 022] received endpoints: 1, 2 17:22:42.838 CNTRLR » [Node 022] querying capabilities for endpoint #1... 17:22:42.842 SERIAL « [ACK] (0x06) 17:22:42.846 SERIAL « 0x0104011301e8 (6 bytes) 17:22:42.846 SERIAL » [ACK] (0x06) 17:22:42.847 DRIVER « [RES] [SendData] was sent: true 17:22:42.863 SERIAL « 0x01070013620000028b (9 bytes) 17:22:42.864 SERIAL » [ACK] (0x06) 17:22:42.865 DRIVER « [REQ] [SendData] callback id: 98 transmit status: OK 17:22:42.874 SERIAL « 0x010c0004001706600a01100125b9 (14 bytes) 17:22:42.875 CNTRLR [Node 023] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 1] [internal] 7 17:22:42.875 SERIAL » [ACK] (0x06) 17:22:42.877 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 17:22:42.881 SERIAL » 0x010b00131804600bffff2563d6 (13 bytes) 17:22:42.881 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 99 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 17:22:42.882 CNTRLR « [Node 023] received response for endpoint capabilities (#1): generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 17:22:42.882 CNTRLR [Node 023] all endpoints idendical, skipping capability query for endpoint #2. .. 17:22:42.883 CNTRLR [Node 023] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 2] [internal] 7 17:22:42.883 CNTRLR [Node 023] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 17:22:42.922 SERIAL « [ACK] (0x06) 17:22:42.928 SERIAL « 0x0104011301e8 (6 bytes) 17:22:42.928 SERIAL » [ACK] (0x06) 17:22:42.930 DRIVER « [RES] [SendData] was sent: true 17:22:42.932 CNTRLR [Node 023] AssociationCC: doing a partial interview... 17:22:42.933 CNTRLR [Node 023] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:22:42.933 CNTRLR [Node 023] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:22:42.934 CNTRLR [Node 023] BinarySwitchCC: doing a partial interview... [Endpoint 1] 17:22:42.934 CNTRLR » [Node 023] querying Binary Switch state... [Endpoint 1] 17:22:42.938 SERIAL « 0x01070013630000038b (9 bytes) 17:22:42.938 SERIAL » [ACK] (0x06) 17:22:42.939 DRIVER « [REQ] [SendData] callback id: 99 transmit status: OK 17:22:42.942 SERIAL « 0x010d0004001807600c00ffff010286 (15 bytes) 17:22:42.942 SERIAL » [ACK] (0x06) 17:22:42.943 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 17:22:42.948 SERIAL » 0x010a001319036009012564d5 (12 bytes) 17:22:42.948 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 100 └─[MultiChannelCCCapabilityGet] endpoint: 1 17:22:42.949 CNTRLR « [Node 024] received endpoints: 1, 2 17:22:42.949 CNTRLR » [Node 024] querying capabilities for endpoint #1... 17:22:42.952 SERIAL « [ACK] (0x06) 17:22:42.956 SERIAL « 0x0104011301e8 (6 bytes) 17:22:42.957 SERIAL » [ACK] (0x06) 17:22:42.957 DRIVER « [RES] [SendData] was sent: true 17:22:42.974 SERIAL « 0x01070013640000028d (9 bytes) 17:22:42.974 SERIAL » [ACK] (0x06) 17:22:42.975 DRIVER « [REQ] [SendData] callback id: 100 transmit status: OK 17:22:42.985 SERIAL « 0x010c0004001906600a01100125b7 (14 bytes) 17:22:42.985 CNTRLR [Node 025] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 1] [internal] 7 17:22:42.986 SERIAL » [ACK] (0x06) 17:22:42.986 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 17:22:42.989 SERIAL » 0x010a0013130370050c2565cf (12 bytes) 17:22:42.990 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 101 └─[ConfigurationCCGet] parameter #: 12 17:22:42.990 CNTRLR « [Node 025] received response for endpoint capabilities (#1): generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 17:22:42.990 CNTRLR [Node 025] all endpoints idendical, skipping capability query for endpoint #2. .. 17:22:42.991 CNTRLR [Node 025] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 2] [internal] 7 17:22:42.991 CNTRLR [Node 025] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 17:22:42.991 CNTRLR [Node 025] AssociationCC: doing a partial interview... 17:22:42.992 CNTRLR [Node 025] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:22:42.992 CNTRLR [Node 025] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:22:42.992 CNTRLR [Node 025] BinarySwitchCC: doing a partial interview... [Endpoint 1] 17:22:42.992 CNTRLR » [Node 025] querying Binary Switch state... [Endpoint 1] 17:22:42.996 SERIAL « [ACK] (0x06) 17:22:42.998 SERIAL « 0x0104011301e8 (6 bytes) 17:22:42.998 SERIAL » [ACK] (0x06) 17:22:42.998 DRIVER « [RES] [SendData] was sent: true 17:22:43.015 SERIAL « 0x01070013650000028c (9 bytes) 17:22:43.015 SERIAL » [ACK] (0x06) 17:22:43.016 DRIVER « [REQ] [SendData] callback id: 101 transmit status: OK 17:22:43.028 SERIAL « 0x010c000400130670060c0200960c (14 bytes) 17:22:43.033 CNTRLR [Node 019] [~] [Configuration] 12: 150 => 150 17:22:43.034 SERIAL » [ACK] (0x06) 17:22:43.035 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 150 17:22:43.038 SERIAL » 0x010900131a02260225669a (11 bytes) 17:22:43.038 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 102 └─[MultilevelSwitchCCGet] 17:22:43.039 CNTRLR « [Node 019] parameter #12 has value: 150 17:22:43.039 CNTRLR » [Node 019] querying parameter #13 value... 17:22:43.042 SERIAL « [ACK] (0x06) 17:22:43.046 SERIAL « 0x0104011301e8 (6 bytes) 17:22:43.046 SERIAL » [ACK] (0x06) 17:22:43.047 DRIVER « [RES] [SendData] was sent: true 17:22:43.109 SERIAL « 0x010700136600000489 (9 bytes) 17:22:43.109 SERIAL » [ACK] (0x06) 17:22:43.111 DRIVER « [REQ] [SendData] callback id: 102 transmit status: OK 17:22:43.132 SERIAL « 0x01090004001a03260363ad (11 bytes) 17:22:43.132 CNTRLR [Node 026] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 0] 17:22:43.133 SERIAL » [ACK] (0x06) 17:22:43.134 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 99 17:22:43.137 SERIAL » 0x010a001316036009012567d9 (12 bytes) 17:22:43.137 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 103 └─[MultiChannelCCCapabilityGet] endpoint: 1 17:22:43.138 CNTRLR [Node 026] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 17:22:43.138 CNTRLR [Node 026] MultilevelSensorCC: doing a partial interview... 17:22:43.139 CNTRLR » [Node 026] querying current sensor reading... 17:22:43.142 SERIAL « [ACK] (0x06) 17:22:43.146 SERIAL « 0x0104011301e8 (6 bytes) 17:22:43.146 SERIAL » [ACK] (0x06) 17:22:43.147 DRIVER « [RES] [SendData] was sent: true 17:22:44.449 SERIAL « 0x01070013670000830f (9 bytes) 17:22:44.450 SERIAL » [ACK] (0x06) 17:22:44.450 DRIVER « [REQ] [SendData] callback id: 103 transmit status: OK 17:22:44.473 SERIAL « 0x011a0004001614600a0108065e8e404353989f596c71758081852296 (28 bytes) 17:22:44.475 CNTRLR [Node 022] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 1] [internal] 64,67,83,152,159,89,108,113,117,128,129,133,34 => 94,142,64,67,83,152,159,89,1 08,113,117,128,129,133,34 17:22:44.475 SERIAL » [ACK] (0x06) 17:22:44.476 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 17:22:44.482 SERIAL » 0x010d00131706600d000125022568f6 (15 bytes) 17:22:44.482 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 104 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 17:22:44.483 CNTRLR « [Node 022] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 17:22:44.484 CNTRLR » [Node 022] querying capabilities for endpoint #2... 17:22:44.488 SERIAL « [ACK] (0x06) 17:22:44.491 SERIAL « 0x0104011301e8 (6 bytes) 17:22:44.491 SERIAL » [ACK] (0x06) 17:22:44.492 DRIVER « [RES] [SendData] was sent: true 17:22:44.509 SERIAL « 0x010700136800000380 (9 bytes) 17:22:44.510 SERIAL » [ACK] (0x06) 17:22:44.511 DRIVER « [REQ] [SendData] callback id: 104 transmit status: OK 17:22:44.520 SERIAL « 0x010d0004001707600d0100250300ac (15 bytes) 17:22:44.522 CNTRLR [Node 023] [~] [Binary Switch] currentValue: false => false [Endpoint 1] 17:22:44.523 SERIAL » [ACK] (0x06) 17:22:44.525 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: false 17:22:44.530 SERIAL » 0x010a001318036009012569d9 (12 bytes) 17:22:44.531 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 105 └─[MultiChannelCCCapabilityGet] endpoint: 1 17:22:44.532 CNTRLR « [Node 023] received Binary Switch state: [Endpoint 1] current value: false 17:22:44.533 CNTRLR [Node 023] [~] [Binary Switch] interviewComplete: true [Endpoint 1] [internal] => true 17:22:44.584 SERIAL « [ACK] (0x06) 17:22:44.589 SERIAL « 0x0104011301e8 (6 bytes) 17:22:44.590 SERIAL » [ACK] (0x06) 17:22:44.592 DRIVER « [RES] [SendData] was sent: true 17:22:44.596 SERIAL « 0x010700136900000381 (9 bytes) 17:22:44.596 SERIAL » [ACK] (0x06) 17:22:44.598 CNTRLR [Node 023] BinarySwitchCC: doing a partial interview... [Endpoint 2] 17:22:44.598 CNTRLR » [Node 023] querying Binary Switch state... [Endpoint 2] 17:22:44.601 DRIVER « [REQ] [SendData] callback id: 105 transmit status: OK 17:22:44.603 SERIAL « 0x0114000400180e600a0110015e862585598e32ef26d7 (22 bytes) 17:22:44.604 CNTRLR [Node 024] [~] [Multi Channel] commandClasses: 94,134, [Endpoint 1] [internal] 37,133,89,142,50 => 94,134,37,133,89,142,50 17:22:44.604 SERIAL » [ACK] (0x06) 17:22:44.605 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Z-Wave Plus Info · Version · Binary Switch · Association · Association Group Information · Multi Channel Association · Meter 17:22:44.608 SERIAL » 0x010d00131906600d00012502256afa (15 bytes) 17:22:44.609 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 106 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 17:22:44.609 CNTRLR « [Node 024] received response for endpoint capabilities (#1): generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Z-Wave Plus Info · Version · Binary Switch · Association · Association Group Information · Multi Channel Association · Meter 17:22:44.609 CNTRLR [Node 024] all endpoints idendical, skipping capability query for endpoint #2. .. 17:22:44.610 CNTRLR [Node 024] [~] [Multi Channel] commandClasses: 94,134, [Endpoint 2] [internal] 37,133,89,142,50 => 94,134,37,133,89,142,50 17:22:44.610 CNTRLR [Node 024] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 17:22:44.611 CNTRLR [Node 024] ZWavePlusCC: doing a partial interview... [Endpoint 1] 17:22:44.615 CNTRLR [Node 024] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 17:22:44.615 CNTRLR [Node 024] BinarySwitchCC: doing a partial interview... [Endpoint 1] 17:22:44.615 CNTRLR » [Node 024] querying Binary Switch state... [Endpoint 1] 17:22:44.622 SERIAL « [ACK] (0x06) 17:22:44.623 SERIAL « 0x0104011301e8 (6 bytes) 17:22:44.623 SERIAL » [ACK] (0x06) 17:22:44.624 DRIVER « [RES] [SendData] was sent: true 17:22:44.635 SERIAL « 0x010700136a00000283 (9 bytes) 17:22:44.636 SERIAL » [ACK] (0x06) 17:22:44.636 DRIVER « [REQ] [SendData] callback id: 106 transmit status: OK 17:22:44.646 SERIAL « 0x010d0004001907600d01002503ff5d (15 bytes) 17:22:44.647 CNTRLR [Node 025] [~] [Binary Switch] currentValue: true => true [Endpoint 1] 17:22:44.648 SERIAL » [ACK] (0x06) 17:22:44.649 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: true 17:22:44.665 SERIAL » 0x010a0013130370050d256bc0 (12 bytes) 17:22:44.666 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 107 └─[ConfigurationCCGet] parameter #: 13 17:22:44.666 CNTRLR « [Node 025] received Binary Switch state: [Endpoint 1] current value: true 17:22:44.667 CNTRLR [Node 025] [~] [Binary Switch] interviewComplete: true [Endpoint 1] [internal] => true 17:22:44.667 CNTRLR [Node 025] BinarySwitchCC: doing a partial interview... [Endpoint 2] 17:22:44.667 CNTRLR » [Node 025] querying Binary Switch state... [Endpoint 2] 17:22:44.671 SERIAL « [ACK] (0x06) 17:22:44.674 SERIAL « 0x0104011301e8 (6 bytes) 17:22:44.674 SERIAL » [ACK] (0x06) 17:22:44.675 DRIVER « [RES] [SendData] was sent: true 17:22:44.691 SERIAL « 0x010700136b00000383 (9 bytes) 17:22:44.691 SERIAL » [ACK] (0x06) 17:22:44.692 DRIVER « [REQ] [SendData] callback id: 107 transmit status: OK 17:22:44.701 SERIAL « 0x010b000400130570060d01019d (13 bytes) 17:22:44.707 CNTRLR [Node 019] [~] [Configuration] 13: 1 => 1 17:22:44.708 SERIAL » [ACK] (0x06) 17:22:44.709 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 1 17:22:44.713 SERIAL » 0x010900131a023104256c81 (11 bytes) 17:22:44.713 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 108 └─[MultilevelSensorCCGet] 17:22:44.714 CNTRLR « [Node 019] parameter #13 has value: 1 17:22:44.714 CNTRLR » [Node 019] querying parameter #14 value... 17:22:44.718 SERIAL « [ACK] (0x06) 17:22:44.721 SERIAL « 0x0104011301e8 (6 bytes) 17:22:44.723 SERIAL » [ACK] (0x06) 17:22:44.724 DRIVER « [RES] [SendData] was sent: true 17:22:44.759 SERIAL « 0x010700136c00000582 (9 bytes) 17:22:44.760 SERIAL » [ACK] (0x06) 17:22:44.760 DRIVER « [REQ] [SendData] callback id: 108 transmit status: OK 17:22:44.807 SERIAL « 0x010c0004001a06310504220000f9 (14 bytes) 17:22:44.808 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:22:44.809 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 17:22:44.809 SERIAL » [ACK] (0x06) 17:22:44.810 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:22:44.813 SERIAL » 0x010a00131603600902256dd0 (12 bytes) 17:22:44.814 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 109 └─[MultiChannelCCCapabilityGet] endpoint: 2 17:22:44.814 CNTRLR « [Node 026] received current sensor reading: sensor type: Power value: 0 W 17:22:44.815 CNTRLR [Node 026] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 17:22:44.815 CNTRLR [Node 026] MeterCC: doing a partial interview... 17:22:44.815 CNTRLR » [Node 026] querying meter value (type = Electric, scale = kWh)... 17:22:44.819 SERIAL « [ACK] (0x06) 17:22:44.822 SERIAL « 0x0104011301e8 (6 bytes) 17:22:44.822 SERIAL » [ACK] (0x06) 17:22:44.823 DRIVER « [RES] [SendData] was sent: true 17:22:44.863 SERIAL « 0x010c0004000306310504220512f7 (14 bytes) 17:22:44.864 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:22:44.865 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 119.4 => 129.8 [Endpoint 0] 17:22:44.865 SERIAL » [ACK] (0x06) 17:22:44.866 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 129.8 17:22:44.969 SERIAL « 0x010c0004000306310504220512f7 (14 bytes) 17:22:44.970 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:22:44.971 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 129.8 => 129.8 [Endpoint 0] 17:22:44.977 SERIAL » [ACK] (0x06) 17:22:44.978 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 129.8 17:22:46.169 SERIAL « 0x01160004001610600a0221015e8e31989f596c7180852226 (24 bytes) 17:22:46.171 CNTRLR [Node 022] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 2] [internal] 49,152,159,89,108,113,128,133,34 => 94,142,49,152,159,89,108,113,128,133,34 17:22:46.171 SERIAL » [ACK] (0x06) 17:22:46.173 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 17:22:47.362 SERIAL « 0x010700136d0000ff79 (9 bytes) 17:22:47.363 SERIAL » [ACK] (0x06) 17:22:47.363 DRIVER « [REQ] [SendData] callback id: 109 transmit status: OK 17:22:47.385 SERIAL « 0x01160004001610600a0221015e8e31989f596c7180852226 (24 bytes) 17:22:47.387 CNTRLR [Node 022] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 2] [internal] 49,152,159,89,108,113,128,133,34 => 94,142,49,152,159,89,108,113,128,133,34 17:22:47.388 SERIAL » [ACK] (0x06) 17:22:47.389 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 17:22:47.396 SERIAL » 0x010d00131706600d00022502256ef3 (15 bytes) 17:22:47.397 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 110 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[BinarySwitchCCGet] 17:22:47.398 CNTRLR « [Node 022] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 17:22:47.398 CNTRLR [Node 022] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 17:22:47.454 SERIAL « [ACK] (0x06) 17:22:47.457 SERIAL « 0x0104011301e8 (6 bytes) 17:22:47.457 SERIAL » [ACK] (0x06) 17:22:47.458 DRIVER « [RES] [SendData] was sent: true 17:22:47.461 CNTRLR [Node 022] BatteryCC: doing a partial interview... 17:22:47.461 CNTRLR » [Node 022] querying battery status... 17:22:47.463 SERIAL « 0x010700136e00000287 (9 bytes) 17:22:47.463 SERIAL » [ACK] (0x06) 17:22:47.464 DRIVER « [REQ] [SendData] callback id: 110 transmit status: OK 17:22:47.466 SERIAL « 0x010d0004001707600d0200250300af (15 bytes) 17:22:47.467 CNTRLR [Node 023] [~] [Binary Switch] currentValue: false => false [Endpoint 2] 17:22:47.467 SERIAL » [ACK] (0x06) 17:22:47.469 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BinarySwitchCCReport] current value: false 17:22:47.472 SERIAL » 0x010d00131806600d00012502256ffe (15 bytes) 17:22:47.472 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 111 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 17:22:47.472 CNTRLR « [Node 023] received Binary Switch state: [Endpoint 2] current value: false 17:22:47.473 CNTRLR [Node 023] [~] [Binary Switch] interviewComplete: true [Endpoint 2] [internal] => true 17:22:47.473 CNTRLR [Node 023] BinarySwitchCC: doing a partial interview... 17:22:47.473 CNTRLR » [Node 023] querying Binary Switch state... 17:22:47.477 SERIAL « [ACK] (0x06) 17:22:47.480 SERIAL « 0x0104011301e8 (6 bytes) 17:22:47.481 SERIAL » [ACK] (0x06) 17:22:47.482 DRIVER « [RES] [SendData] was sent: true 17:22:47.502 SERIAL « 0x010700136f00000387 (9 bytes) 17:22:47.502 SERIAL » [ACK] (0x06) 17:22:47.503 DRIVER « [REQ] [SendData] callback id: 111 transmit status: OK 17:22:47.517 SERIAL « 0x010d0004001807600d0100250300a3 (15 bytes) 17:22:47.518 CNTRLR [Node 024] [~] [Binary Switch] currentValue: false => false [Endpoint 1] 17:22:47.518 SERIAL » [ACK] (0x06) 17:22:47.519 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: false 17:22:47.522 SERIAL » 0x010d00131906600d000225022570e3 (15 bytes) 17:22:47.523 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 112 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[BinarySwitchCCGet] 17:22:47.523 CNTRLR « [Node 024] received Binary Switch state: [Endpoint 1] current value: false 17:22:47.523 CNTRLR [Node 024] [~] [Binary Switch] interviewComplete: true [Endpoint 1] [internal] => true 17:22:47.524 CNTRLR [Node 024] MeterCC: doing a partial interview... [Endpoint 1] 17:22:47.524 CNTRLR » [Node 024] querying default meter value... [Endpoint 1] 17:22:47.527 SERIAL « [ACK] (0x06) 17:22:47.532 SERIAL « 0x0104011301e8 (6 bytes) 17:22:47.533 SERIAL » [ACK] (0x06) 17:22:47.534 DRIVER « [RES] [SendData] was sent: true 17:22:47.549 SERIAL « 0x010700137000000398 (9 bytes) 17:22:47.550 SERIAL » [ACK] (0x06) 17:22:47.550 DRIVER « [REQ] [SendData] callback id: 112 transmit status: OK 17:22:47.560 SERIAL « 0x010d0004001907600d02002503ff5e (15 bytes) 17:22:47.561 CNTRLR [Node 025] [~] [Binary Switch] currentValue: true => true [Endpoint 2] 17:22:47.561 SERIAL » [ACK] (0x06) 17:22:47.562 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BinarySwitchCCReport] current value: true 17:22:47.587 SERIAL » 0x010a0013130370050e2571d9 (12 bytes) 17:22:47.587 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 113 └─[ConfigurationCCGet] parameter #: 14 17:22:47.588 CNTRLR « [Node 025] received Binary Switch state: [Endpoint 2] current value: true 17:22:47.588 CNTRLR [Node 025] [~] [Binary Switch] interviewComplete: true [Endpoint 2] [internal] => true 17:22:47.588 CNTRLR [Node 025] BinarySwitchCC: doing a partial interview... 17:22:47.588 CNTRLR » [Node 025] querying Binary Switch state... 17:22:47.593 SERIAL « [ACK] (0x06) 17:22:47.597 SERIAL « 0x0104011301e8 (6 bytes) 17:22:47.598 SERIAL » [ACK] (0x06) 17:22:47.601 DRIVER « [RES] [SendData] was sent: true 17:22:47.637 SERIAL « 0x010700137100000298 (9 bytes) 17:22:47.638 SERIAL » [ACK] (0x06) 17:22:47.638 DRIVER « [REQ] [SendData] callback id: 113 transmit status: OK 17:22:47.641 SERIAL « 0x010b000400130570060e01009f (13 bytes) 17:22:47.646 CNTRLR [Node 019] [~] [Configuration] 14: 0 => 0 17:22:47.647 SERIAL » [ACK] (0x06) 17:22:47.648 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 0 17:22:47.651 SERIAL » 0x010a00131a0332010025729b (12 bytes) 17:22:47.651 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 114 └─[MeterCCGet] duration: kWh 17:22:47.652 CNTRLR « [Node 019] parameter #14 has value: 0 17:22:47.652 CNTRLR » [Node 019] querying parameter #17 value... 17:22:47.655 SERIAL « [ACK] (0x06) 17:22:47.659 SERIAL « 0x0104011301e8 (6 bytes) 17:22:47.660 SERIAL » [ACK] (0x06) 17:22:47.662 DRIVER « [RES] [SendData] was sent: true 17:22:47.699 SERIAL « 0x01070013720000059c (9 bytes) 17:22:47.699 SERIAL » [ACK] (0x06) 17:22:47.700 DRIVER « [REQ] [SendData] callback id: 114 transmit status: OK 17:22:47.750 SERIAL « 0x01100004001a0a32022144000001da000075 (18 bytes) 17:22:47.751 CNTRLR [Node 026] [~] [Meter] value[65537]: 4.74 => 4.74 [Endpoint 0] 17:22:47.751 CNTRLR [Node 026] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 17:22:47.752 SERIAL » [ACK] (0x06) 17:22:47.753 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 4.74 time delta: 0 seconds 17:22:47.756 SERIAL » 0x0109001316028002257325 (11 bytes) 17:22:47.756 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 115 └─[BatteryCCGet] 17:22:47.757 CNTRLR » [Node 026] querying meter value (type = Electric, scale = W)... 17:22:47.760 SERIAL « [ACK] (0x06) 17:22:47.765 SERIAL « 0x0104011301e8 (6 bytes) 17:22:47.765 SERIAL » [ACK] (0x06) 17:22:47.766 DRIVER « [RES] [SendData] was sent: true 17:22:49.099 SERIAL « 0x01070013730000851d (9 bytes) 17:22:49.099 SERIAL » [ACK] (0x06) 17:22:49.100 DRIVER « [REQ] [SendData] callback id: 115 transmit status: OK 17:22:49.212 SERIAL « 0x0109000400160380036307 (11 bytes) 17:22:49.213 CNTRLR [Node 022] [~] [Battery] level: 99 => 99 [Endpoint 0] 17:22:49.215 CNTRLR [Node 022] [~] [Battery] isLow: false => false [Endpoint 0] 17:22:49.215 SERIAL » [ACK] (0x06) 17:22:49.226 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 99 is low: false 17:22:49.243 SERIAL » 0x0109001317022502257486 (11 bytes) 17:22:49.243 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 116 └─[BinarySwitchCCGet] 17:22:49.244 CNTRLR « [Node 022] received response for battery information: level: 99 17:22:49.245 CNTRLR [Node 022] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:22:49.297 SERIAL « [ACK] (0x06) 17:22:49.302 SERIAL « 0x0104011301e8 (6 bytes) 17:22:49.302 SERIAL » [ACK] (0x06) 17:22:49.305 DRIVER « [RES] [SendData] was sent: true 17:22:49.313 CNTRLR [Node 022] ZWavePlusCC: doing a partial interview... [Endpoint 1] 17:22:49.313 CNTRLR [Node 022] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 17:22:49.314 CNTRLR [Node 022] ThermostatModeCC: doing a partial interview... [Endpoint 1] 17:22:49.314 CNTRLR » [Node 022] querying current thermostat mode... [Endpoint 1] 17:22:49.319 SERIAL « 0x01070013740000039c (9 bytes) 17:22:49.319 SERIAL » [ACK] (0x06) 17:22:49.320 DRIVER « [REQ] [SendData] callback id: 116 transmit status: OK 17:22:49.324 SERIAL « 0x01090004001703250300c0 (11 bytes) 17:22:49.325 CNTRLR [Node 023] [~] [Binary Switch] currentValue: false => false [Endpoint 0] 17:22:49.326 SERIAL » [ACK] (0x06) 17:22:49.327 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 17:22:49.333 SERIAL » 0x010d00131806600d000132012575f0 (15 bytes) 17:22:49.333 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 117 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[MeterCCGet] 17:22:49.334 CNTRLR « [Node 023] received Binary Switch state: current value: false 17:22:49.335 CNTRLR [Node 023] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 17:22:49.336 CNTRLR [Node 023] ConfigurationCC: Loading configuration parameters from device confi g 17:22:49.342 CNTRLR [Node 023] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:22:49.342 CNTRLR [Node 023] [Configuration] 1: metadata updated 17:22:49.343 CNTRLR [Node 023] [Configuration] 3: metadata updated 17:22:49.344 CNTRLR [Node 023] [Configuration] 4: metadata updated 17:22:49.346 CNTRLR [Node 023] [Configuration] 5: metadata updated 17:22:49.347 CNTRLR [Node 023] [Configuration] 6: metadata updated 17:22:49.348 CNTRLR [Node 023] [Configuration] 7: metadata updated 17:22:49.349 CNTRLR [Node 023] [Configuration] 13: metadata updated 17:22:49.350 CNTRLR [Node 023] [Configuration] 14: metadata updated 17:22:49.351 CNTRLR [Node 023] [Configuration] 15: metadata updated 17:22:49.352 CNTRLR [Node 023] [Configuration] 16: metadata updated 17:22:49.353 CNTRLR [Node 023] [Configuration] 30: metadata updated 17:22:49.354 CNTRLR [Node 023] [Configuration] 31: metadata updated 17:22:49.356 CNTRLR [Node 023] [Configuration] 32: metadata updated 17:22:49.357 CNTRLR [Node 023] [Configuration] 33: metadata updated 17:22:49.358 CNTRLR [Node 023] [Configuration] 39: metadata updated 17:22:49.359 CNTRLR [Node 023] [Configuration] 40: metadata updated 17:22:49.360 CNTRLR [Node 023] [Configuration] 41: metadata updated 17:22:49.361 CNTRLR [Node 023] [Configuration] 42: metadata updated 17:22:49.362 CNTRLR [Node 023] [Configuration] 43: metadata updated 17:22:49.363 CNTRLR [Node 023] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:22:49.363 CNTRLR » [Node 023] querying parameter #1 value... 17:22:49.369 SERIAL « [ACK] (0x06) 17:22:49.370 SERIAL « 0x0104011301e8 (6 bytes) 17:22:49.370 SERIAL » [ACK] (0x06) 17:22:49.372 DRIVER « [RES] [SendData] was sent: true 17:22:49.383 SERIAL « 0x01070013750000039d (9 bytes) 17:22:49.384 SERIAL » [ACK] (0x06) 17:22:49.386 DRIVER « [REQ] [SendData] callback id: 117 transmit status: OK 17:22:49.391 SERIAL « 0x0112000400180c600d010032020144000001bf5a (20 bytes) 17:22:49.393 CNTRLR [Node 024] [~] [Meter] value[65536]: 4.47 => 4.47 [Endpoint 1] 17:22:49.394 CNTRLR [Node 024] [~] [Meter] deltaTime[65536]: 0 => 0 [Endpoint 1] 17:22:49.395 SERIAL » [ACK] (0x06) 17:22:49.398 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[MeterCCReport] type: Electric scale: kWh rate type: Unspecified value: 4.47 time delta: 0 seconds 17:22:49.403 SERIAL » 0x010900131902250225768a (11 bytes) 17:22:49.403 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 118 └─[BinarySwitchCCGet] 17:22:49.404 CNTRLR [Node 024] [~] [Meter] interviewComplete: true => true [Endpoint 1] [internal] 17:22:49.406 CNTRLR [Node 024] ZWavePlusCC: doing a partial interview... [Endpoint 2] 17:22:49.407 CNTRLR [Node 024] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 17:22:49.407 CNTRLR [Node 024] BinarySwitchCC: doing a partial interview... [Endpoint 2] 17:22:49.408 CNTRLR » [Node 024] querying Binary Switch state... [Endpoint 2] 17:22:49.423 SERIAL « [ACK] (0x06) 17:22:49.424 SERIAL « 0x0104011301e8 (6 bytes) 17:22:49.425 SERIAL » [ACK] (0x06) 17:22:49.429 DRIVER « [RES] [SendData] was sent: true 17:22:49.434 SERIAL « 0x01070013760000039e (9 bytes) 17:22:49.436 SERIAL » [ACK] (0x06) 17:22:49.439 DRIVER « [REQ] [SendData] callback id: 118 transmit status: OK 17:22:49.446 SERIAL « 0x010900040019032503ff31 (11 bytes) 17:22:49.448 CNTRLR [Node 025] [~] [Binary Switch] currentValue: true => true [Endpoint 0] 17:22:49.448 SERIAL » [ACK] (0x06) 17:22:49.449 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: true 17:22:49.454 SERIAL » 0x010a001313037005112577c0 (12 bytes) 17:22:49.455 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 119 └─[ConfigurationCCGet] parameter #: 17 17:22:49.455 CNTRLR « [Node 025] received Binary Switch state: current value: true 17:22:49.456 CNTRLR [Node 025] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 17:22:49.456 CNTRLR [Node 025] ConfigurationCC: Loading configuration parameters from device confi g 17:22:49.462 CNTRLR [Node 025] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:22:49.462 CNTRLR [Node 025] [Configuration] 1: metadata updated 17:22:49.463 CNTRLR [Node 025] [Configuration] 3: metadata updated 17:22:49.464 CNTRLR [Node 025] [Configuration] 4: metadata updated 17:22:49.465 CNTRLR [Node 025] [Configuration] 5: metadata updated 17:22:49.466 CNTRLR [Node 025] [Configuration] 6: metadata updated 17:22:49.468 CNTRLR [Node 025] [Configuration] 7: metadata updated 17:22:49.469 CNTRLR [Node 025] [Configuration] 13: metadata updated 17:22:49.470 CNTRLR [Node 025] [Configuration] 14: metadata updated 17:22:49.471 CNTRLR [Node 025] [Configuration] 15: metadata updated 17:22:49.472 CNTRLR [Node 025] [Configuration] 16: metadata updated 17:22:49.473 CNTRLR [Node 025] [Configuration] 30: metadata updated 17:22:49.474 CNTRLR [Node 025] [Configuration] 31: metadata updated 17:22:49.475 CNTRLR [Node 025] [Configuration] 32: metadata updated 17:22:49.476 CNTRLR [Node 025] [Configuration] 33: metadata updated 17:22:49.477 CNTRLR [Node 025] [Configuration] 39: metadata updated 17:22:49.478 CNTRLR [Node 025] [Configuration] 40: metadata updated 17:22:49.480 CNTRLR [Node 025] [Configuration] 41: metadata updated 17:22:49.481 CNTRLR [Node 025] [Configuration] 42: metadata updated 17:22:49.482 CNTRLR [Node 025] [Configuration] 43: metadata updated 17:22:49.483 CNTRLR [Node 025] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:22:49.483 CNTRLR » [Node 025] querying parameter #1 value... 17:22:49.514 SERIAL « [ACK] (0x06) 17:22:49.515 SERIAL « 0x0104011301e8 (6 bytes) 17:22:49.516 SERIAL » [ACK] (0x06) 17:22:49.520 DRIVER « [RES] [SendData] was sent: true 17:22:49.531 SERIAL « 0x01070013770000039f (9 bytes) 17:22:49.531 SERIAL » [ACK] (0x06) 17:22:49.533 DRIVER « [REQ] [SendData] callback id: 119 transmit status: OK 17:22:49.536 SERIAL « 0x010b0004001305700611010a8a (13 bytes) 17:22:49.542 CNTRLR [Node 019] [~] [Configuration] 17: 10 => 10 17:22:49.542 SERIAL » [ACK] (0x06) 17:22:49.544 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 17 value size: 1 value: 10 17:22:49.554 SERIAL » 0x010a00131a03320110257881 (12 bytes) 17:22:49.555 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 120 └─[MeterCCGet] duration: W 17:22:49.555 CNTRLR « [Node 019] parameter #17 has value: 10 17:22:49.555 CNTRLR » [Node 019] querying parameter #18 value... 17:22:49.564 SERIAL « [ACK] (0x06) 17:22:49.567 SERIAL « 0x0104011301e8 (6 bytes) 17:22:49.568 SERIAL » [ACK] (0x06) 17:22:49.568 DRIVER « [RES] [SendData] was sent: true 17:22:49.602 SERIAL « 0x010700137800000596 (9 bytes) 17:22:49.602 SERIAL » [ACK] (0x06) 17:22:49.604 DRIVER « [REQ] [SendData] callback id: 120 transmit status: OK 17:22:49.651 SERIAL « 0x010e0004001a083202213200000000c4 (16 bytes) 17:22:49.652 CNTRLR [Node 026] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 17:22:49.652 CNTRLR [Node 026] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 17:22:49.653 SERIAL » [ACK] (0x06) 17:22:49.654 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 17:22:49.657 SERIAL » 0x010d00131606600d00014002257983 (15 bytes) 17:22:49.658 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 121 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 17:22:49.659 CNTRLR [Node 026] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 17:22:49.659 CNTRLR [Node 026] ConfigurationCC: Loading configuration parameters from device confi g 17:22:49.664 CNTRLR [Node 026] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:22:49.665 CNTRLR [Node 026] [Configuration] 3: metadata updated 17:22:49.666 CNTRLR [Node 026] [Configuration] 10: metadata updated 17:22:49.667 CNTRLR [Node 026] [Configuration] 12: metadata updated 17:22:49.668 CNTRLR [Node 026] [Configuration] 13: metadata updated 17:22:49.669 CNTRLR [Node 026] [Configuration] 14: metadata updated 17:22:49.670 CNTRLR [Node 026] [Configuration] 17: metadata updated 17:22:49.671 CNTRLR [Node 026] [Configuration] 18: metadata updated 17:22:49.672 CNTRLR [Node 026] [Configuration] 22: metadata updated 17:22:49.673 CNTRLR [Node 026] [Configuration] 29: metadata updated 17:22:49.674 CNTRLR [Node 026] [Configuration] 30: metadata updated 17:22:49.681 CNTRLR [Node 026] [Configuration] 31: metadata updated 17:22:49.683 CNTRLR [Node 026] [Configuration] 32: metadata updated 17:22:49.684 CNTRLR [Node 026] [Configuration] 33: metadata updated 17:22:49.691 CNTRLR [Node 026] [Configuration] 35: metadata updated 17:22:49.692 CNTRLR [Node 026] [Configuration] 40: metadata updated 17:22:49.693 CNTRLR [Node 026] [Configuration] 42: metadata updated 17:22:49.694 CNTRLR [Node 026] [Configuration] 43: metadata updated 17:22:49.695 CNTRLR [Node 026] [Configuration] 44: metadata updated 17:22:49.696 CNTRLR [Node 026] [Configuration] 50: metadata updated 17:22:49.697 CNTRLR [Node 026] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:22:49.697 CNTRLR » [Node 026] querying parameter #3 value... 17:22:49.704 SERIAL « [ACK] (0x06) 17:22:49.705 SERIAL « 0x0104011301e8 (6 bytes) 17:22:49.705 SERIAL » [ACK] (0x06) 17:22:49.706 DRIVER « [RES] [SendData] was sent: true 17:22:49.740 SERIAL « 0x01070013790000089a (9 bytes) 17:22:49.741 SERIAL » [ACK] (0x06) 17:22:49.741 DRIVER « [REQ] [SendData] callback id: 121 transmit status: OK 17:22:49.840 SERIAL « 0x010d0004001607600d0100400301c9 (15 bytes) 17:22:49.842 CNTRLR [Node 022] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 17:22:49.842 SERIAL » [ACK] (0x06) 17:22:49.843 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 17:22:49.848 SERIAL » 0x010a00131703700501257ad9 (12 bytes) 17:22:49.848 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 122 └─[ConfigurationCCGet] parameter #: 1 17:22:49.849 CNTRLR « [Node 022] received current thermostat mode: Heat [Endpoint 1] 17:22:49.849 CNTRLR [Node 022] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 1] [internal] ue => true 17:22:49.850 CNTRLR [Node 022] ThermostatSetpointCC: doing a partial interview... [Endpoint 1] 17:22:49.850 CNTRLR » [Node 022] querying current value of setpoint Heating... [Endpoint 1] 17:22:49.859 SERIAL « [ACK] (0x06) 17:22:49.861 SERIAL « 0x0104011301e8 (6 bytes) 17:22:49.861 SERIAL » [ACK] (0x06) 17:22:49.862 DRIVER « [RES] [SendData] was sent: true 17:22:49.874 SERIAL « 0x010700137a00000293 (9 bytes) 17:22:49.875 SERIAL » [ACK] (0x06) 17:22:49.875 DRIVER « [REQ] [SendData] callback id: 122 transmit status: OK 17:22:49.884 SERIAL « 0x010b000400170570060101ff6b (13 bytes) 17:22:49.891 CNTRLR [Node 023] [~] [Configuration] 1: 255 => 255 17:22:49.892 SERIAL » [ACK] (0x06) 17:22:49.905 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 255 17:22:49.910 SERIAL » 0x010d00131806600d00022502257be9 (15 bytes) 17:22:49.911 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 123 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[BinarySwitchCCGet] 17:22:49.919 CNTRLR « [Node 023] parameter #1 has value: 255 17:22:49.919 CNTRLR » [Node 023] querying parameter #3 value... 17:22:49.933 SERIAL « [ACK] (0x06) 17:22:49.934 SERIAL « 0x0104011301e8 (6 bytes) 17:22:49.935 SERIAL » [ACK] (0x06) 17:22:49.937 DRIVER « [RES] [SendData] was sent: true 17:22:49.945 SERIAL « 0x010700137b00000393 (9 bytes) 17:22:49.945 SERIAL » [ACK] (0x06) 17:22:49.946 DRIVER « [REQ] [SendData] callback id: 123 transmit status: OK 17:22:49.955 SERIAL « 0x010d0004001807600d0200250300a0 (15 bytes) 17:22:49.956 CNTRLR [Node 024] [~] [Binary Switch] currentValue: false => false [Endpoint 2] 17:22:49.957 SERIAL » [ACK] (0x06) 17:22:49.958 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BinarySwitchCCReport] current value: false 17:22:49.962 SERIAL » 0x010a00131903700501257cd1 (12 bytes) 17:22:49.962 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 124 └─[ConfigurationCCGet] parameter #: 1 17:22:49.963 CNTRLR « [Node 024] received Binary Switch state: [Endpoint 2] current value: false 17:22:49.963 CNTRLR [Node 024] [~] [Binary Switch] interviewComplete: true [Endpoint 2] [internal] => true 17:22:49.964 CNTRLR [Node 024] MeterCC: doing a partial interview... [Endpoint 2] 17:22:49.964 CNTRLR » [Node 024] querying default meter value... [Endpoint 2] 17:22:49.968 SERIAL « [ACK] (0x06) 17:22:49.970 SERIAL « 0x0104011301e8 (6 bytes) 17:22:49.973 SERIAL » [ACK] (0x06) 17:22:49.974 DRIVER « [RES] [SendData] was sent: true 17:22:49.989 SERIAL « 0x010700137c00000295 (9 bytes) 17:22:49.989 SERIAL » [ACK] (0x06) 17:22:49.990 DRIVER « [REQ] [SendData] callback id: 124 transmit status: OK 17:22:49.999 SERIAL « 0x010b000400190570060101ff65 (13 bytes) 17:22:50.006 CNTRLR [Node 025] [~] [Configuration] 1: 255 => 255 17:22:50.008 SERIAL » [ACK] (0x06) 17:22:50.009 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 255 17:22:50.013 SERIAL » 0x010a00131303700512257dc9 (12 bytes) 17:22:50.013 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 125 └─[ConfigurationCCGet] parameter #: 18 17:22:50.014 CNTRLR « [Node 025] parameter #1 has value: 255 17:22:50.014 CNTRLR » [Node 025] querying parameter #3 value... 17:22:50.045 SERIAL « [ACK] (0x06) 17:22:50.046 SERIAL « 0x0104011301e8 (6 bytes) 17:22:50.046 SERIAL » [ACK] (0x06) 17:22:50.047 DRIVER « [RES] [SendData] was sent: true 17:22:50.049 SERIAL « 0x010700137d00000294 (9 bytes) 17:22:50.050 SERIAL » [ACK] (0x06) 17:22:50.051 DRIVER « [REQ] [SendData] callback id: 125 transmit status: OK 17:22:50.054 SERIAL « 0x010b0004001305700612010a89 (13 bytes) 17:22:50.059 CNTRLR [Node 019] [~] [Configuration] 18: 10 => 10 17:22:50.060 SERIAL » [ACK] (0x06) 17:22:50.061 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 18 value size: 1 value: 10 17:22:50.065 SERIAL » 0x010a00131a03700503257ed2 (12 bytes) 17:22:50.066 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 126 └─[ConfigurationCCGet] parameter #: 3 17:22:50.066 CNTRLR « [Node 019] parameter #18 has value: 10 17:22:50.066 CNTRLR » [Node 019] querying parameter #22 value... 17:22:50.070 SERIAL « [ACK] (0x06) 17:22:50.074 SERIAL « 0x0104011301e8 (6 bytes) 17:22:50.074 SERIAL » [ACK] (0x06) 17:22:50.075 DRIVER « [RES] [SendData] was sent: true 17:22:50.112 SERIAL « 0x010700137e00000590 (9 bytes) 17:22:50.113 SERIAL » [ACK] (0x06) 17:22:50.113 DRIVER « [REQ] [SendData] callback id: 126 transmit status: OK 17:22:50.159 SERIAL « 0x010b0004001a0570060301009b (13 bytes) 17:22:50.165 CNTRLR [Node 026] [~] [Configuration] 3: 0 => 0 17:22:50.166 SERIAL » [ACK] (0x06) 17:22:50.167 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 17:22:50.172 SERIAL » 0x010e00131607600d0001430201257f85 (16 bytes) 17:22:50.173 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 127 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 17:22:50.174 CNTRLR « [Node 026] parameter #3 has value: 0 17:22:50.174 CNTRLR » [Node 026] querying parameter #10 value... 17:22:50.178 SERIAL « [ACK] (0x06) 17:22:50.181 SERIAL « 0x0104011301e8 (6 bytes) 17:22:50.182 SERIAL » [ACK] (0x06) 17:22:50.183 DRIVER « [RES] [SendData] was sent: true 17:22:50.251 SERIAL « 0x010700137f0000089c (9 bytes) 17:22:50.251 SERIAL » [ACK] (0x06) 17:22:50.252 DRIVER « [REQ] [SendData] callback id: 127 transmit status: OK 17:22:50.340 SERIAL « 0x0110000400160a600d01004303012200649c (18 bytes) 17:22:50.342 CNTRLR [Node 022] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 1] 17:22:50.343 CNTRLR [Node 022] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 17:22:50.343 SERIAL » [ACK] (0x06) 17:22:50.345 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 17:22:50.349 SERIAL » 0x010a00131703700503258021 (12 bytes) 17:22:50.350 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 128 └─[ConfigurationCCGet] parameter #: 3 17:22:50.350 CNTRLR « [Node 022] received current value of setpoint Heating: 10 °C [Endpoint 1] 17:22:50.351 CNTRLR [Node 022] [~] [Thermostat Setpoint] interviewComplete [Endpoint 1] [internal] : true => true 17:22:50.352 CNTRLR [Node 022] NotificationCC: doing a partial interview... [Endpoint 1] 17:22:50.352 CNTRLR [Node 022] [~] [Notification] interviewComplete: true [Endpoint 1] [internal] => true 17:22:50.353 CNTRLR [Node 022] ProtectionCC: doing a partial interview... 17:22:50.353 CNTRLR » [Node 022] querying protection status... 17:22:50.360 SERIAL « [ACK] (0x06) 17:22:50.361 SERIAL « 0x0104011301e8 (6 bytes) 17:22:50.362 SERIAL » [ACK] (0x06) 17:22:50.363 DRIVER « [RES] [SendData] was sent: true 17:22:50.375 SERIAL « 0x010700138000000269 (9 bytes) 17:22:50.376 SERIAL » [ACK] (0x06) 17:22:50.376 DRIVER « [REQ] [SendData] callback id: 128 transmit status: OK 17:22:50.386 SERIAL « 0x010b0004001705700603010096 (13 bytes) 17:22:50.392 CNTRLR [Node 023] [~] [Configuration] 3: 0 => 0 17:22:50.393 SERIAL » [ACK] (0x06) 17:22:50.394 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 17:22:50.398 SERIAL » 0x010d00131806600d00023201258107 (15 bytes) 17:22:50.398 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 129 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MeterCCGet] 17:22:50.398 CNTRLR « [Node 023] parameter #3 has value: 0 17:22:50.399 CNTRLR » [Node 023] querying parameter #4 value... 17:22:50.402 SERIAL « [ACK] (0x06) 17:22:50.406 SERIAL « 0x0104011301e8 (6 bytes) 17:22:50.407 SERIAL » [ACK] (0x06) 17:22:50.407 DRIVER « [RES] [SendData] was sent: true 17:22:50.428 SERIAL « 0x010700138100000268 (9 bytes) 17:22:50.428 SERIAL » [ACK] (0x06) 17:22:50.428 DRIVER « [REQ] [SendData] callback id: 129 transmit status: OK 17:22:50.444 SERIAL « 0x0112000400180c600d02003202014400006d0389 (20 bytes) 17:22:50.446 CNTRLR [Node 024] [~] [Meter] value[65536]: 278.5 => 279.07 [Endpoint 2] 17:22:50.446 CNTRLR [Node 024] [~] [Meter] deltaTime[65536]: 0 => 0 [Endpoint 2] 17:22:50.447 SERIAL » [ACK] (0x06) 17:22:50.448 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: kWh rate type: Unspecified value: 279.07 time delta: 0 seconds 17:22:50.451 SERIAL » 0x010a0013190370050325822d (12 bytes) 17:22:50.452 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 130 └─[ConfigurationCCGet] parameter #: 3 17:22:50.452 CNTRLR [Node 024] [~] [Meter] interviewComplete: true => true [Endpoint 2] [internal] 17:22:50.453 CNTRLR [Node 024] BinarySwitchCC: doing a partial interview... 17:22:50.453 CNTRLR » [Node 024] querying Binary Switch state... 17:22:50.457 SERIAL « [ACK] (0x06) 17:22:50.460 SERIAL « 0x0104011301e8 (6 bytes) 17:22:50.460 SERIAL » [ACK] (0x06) 17:22:50.461 DRIVER « [RES] [SendData] was sent: true 17:22:50.477 SERIAL « 0x01070013820000026b (9 bytes) 17:22:50.478 SERIAL » [ACK] (0x06) 17:22:50.478 DRIVER « [REQ] [SendData] callback id: 130 transmit status: OK 17:22:50.487 SERIAL « 0x010b0004001905700603010098 (13 bytes) 17:22:50.493 CNTRLR [Node 025] [~] [Configuration] 3: 0 => 0 17:22:50.494 SERIAL » [ACK] (0x06) 17:22:50.494 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 17:22:50.498 SERIAL » 0x010a00131303700516258333 (12 bytes) 17:22:50.498 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 131 └─[ConfigurationCCGet] parameter #: 22 17:22:50.498 CNTRLR « [Node 025] parameter #3 has value: 0 17:22:50.499 CNTRLR » [Node 025] querying parameter #4 value... 17:22:50.502 SERIAL « [ACK] (0x06) 17:22:50.507 SERIAL « 0x0104011301e8 (6 bytes) 17:22:50.507 SERIAL » [ACK] (0x06) 17:22:50.508 DRIVER « [RES] [SendData] was sent: true 17:22:50.523 SERIAL « 0x01070013830000026a (9 bytes) 17:22:50.524 SERIAL » [ACK] (0x06) 17:22:50.524 DRIVER « [REQ] [SendData] callback id: 131 transmit status: OK 17:22:50.535 SERIAL « 0x010c00040013067006160200f070 (14 bytes) 17:22:50.540 CNTRLR [Node 019] [~] [Configuration] 22: 240 => 240 17:22:50.541 SERIAL » [ACK] (0x06) 17:22:50.542 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 240 17:22:50.549 SERIAL » 0x010a00131a0370050a258421 (12 bytes) 17:22:50.550 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 132 └─[ConfigurationCCGet] parameter #: 10 17:22:50.550 CNTRLR « [Node 019] parameter #22 has value: 240 17:22:50.550 CNTRLR » [Node 019] querying parameter #29 value... 17:22:50.553 SERIAL « [ACK] (0x06) 17:22:50.558 SERIAL « 0x0104011301e8 (6 bytes) 17:22:50.559 SERIAL » [ACK] (0x06) 17:22:50.559 DRIVER « [RES] [SendData] was sent: true 17:22:50.596 SERIAL « 0x01070013840000046b (9 bytes) 17:22:50.596 SERIAL » [ACK] (0x06) 17:22:50.597 DRIVER « [REQ] [SendData] callback id: 132 transmit status: OK 17:22:50.644 SERIAL « 0x010b0004001a0570060a010193 (13 bytes) 17:22:50.649 CNTRLR [Node 026] [~] [Configuration] 10: 1 => 1 17:22:50.650 SERIAL » [ACK] (0x06) 17:22:50.651 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 1 17:22:50.655 SERIAL » 0x010d00131606600d0001750225854a (15 bytes) 17:22:50.655 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 133 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 17:22:50.656 CNTRLR « [Node 026] parameter #10 has value: 1 17:22:50.656 CNTRLR » [Node 026] querying parameter #12 value... 17:22:50.659 SERIAL « [ACK] (0x06) 17:22:50.665 SERIAL « 0x0104011301e8 (6 bytes) 17:22:50.665 SERIAL » [ACK] (0x06) 17:22:50.666 DRIVER « [RES] [SendData] was sent: true 17:22:50.729 SERIAL « 0x010700138500000769 (9 bytes) 17:22:50.730 SERIAL » [ACK] (0x06) 17:22:50.730 DRIVER « [REQ] [SendData] callback id: 133 transmit status: OK 17:22:50.815 SERIAL « 0x010d0004001607600d0100750300fd (15 bytes) 17:22:50.817 CNTRLR [Node 022] [~] [Protection] local: 0 => 0 [Endpoint 1] 17:22:50.817 SERIAL » [ACK] (0x06) 17:22:50.819 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ProtectionCCReport] local: Unprotected 17:22:50.823 SERIAL » 0x010a00131703700504258620 (12 bytes) 17:22:50.823 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 134 └─[ConfigurationCCGet] parameter #: 4 17:22:50.824 CNTRLR « [Node 022] received protection status: local: Unprotected 17:22:50.825 CNTRLR [Node 022] [~] [Protection] interviewComplete: true => [Endpoint 1] [internal] true 17:22:50.825 CNTRLR [Node 022] BatteryCC: doing a partial interview... [Endpoint 1] 17:22:50.825 CNTRLR » [Node 022] querying battery status... [Endpoint 1] 17:22:50.830 SERIAL « [ACK] (0x06) 17:22:50.832 SERIAL « 0x0104011301e8 (6 bytes) 17:22:50.833 SERIAL » [ACK] (0x06) 17:22:50.834 DRIVER « [RES] [SendData] was sent: true 17:22:50.849 SERIAL « 0x01070013860000036e (9 bytes) 17:22:50.850 SERIAL » [ACK] (0x06) 17:22:50.850 DRIVER « [REQ] [SendData] callback id: 134 transmit status: OK 17:22:50.860 SERIAL « 0x010c000400170670060402000096 (14 bytes) 17:22:50.867 CNTRLR [Node 023] [~] [Configuration] 4: 0 => 0 17:22:50.868 SERIAL » [ACK] (0x06) 17:22:50.869 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 2 value: 0 17:22:50.873 SERIAL » 0x010900131802250225877a (11 bytes) 17:22:50.874 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 135 └─[BinarySwitchCCGet] 17:22:50.875 CNTRLR « [Node 023] parameter #4 has value: 0 17:22:50.875 CNTRLR » [Node 023] querying parameter #5 value... 17:22:50.879 SERIAL « [ACK] (0x06) 17:22:50.882 SERIAL « 0x0104011301e8 (6 bytes) 17:22:50.883 SERIAL » [ACK] (0x06) 17:22:50.885 DRIVER « [RES] [SendData] was sent: true 17:22:50.903 SERIAL « 0x01070013870000036f (9 bytes) 17:22:50.903 SERIAL » [ACK] (0x06) 17:22:50.904 DRIVER « [REQ] [SendData] callback id: 135 transmit status: OK 17:22:50.916 SERIAL « 0x01090004001803250300cf (11 bytes) 17:22:50.917 CNTRLR [Node 024] [~] [Binary Switch] currentValue: false => false [Endpoint 0] 17:22:50.918 SERIAL » [ACK] (0x06) 17:22:50.919 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 17:22:50.923 SERIAL » 0x010a00131903700504258820 (12 bytes) 17:22:50.924 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 136 └─[ConfigurationCCGet] parameter #: 4 17:22:50.924 CNTRLR « [Node 024] received Binary Switch state: current value: false 17:22:50.925 CNTRLR [Node 024] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 17:22:50.926 CNTRLR [Node 024] MeterCC: doing a partial interview... 17:22:50.926 CNTRLR » [Node 024] querying meter value (type = Electric, scale = kWh)... 17:22:50.931 SERIAL « [ACK] (0x06) 17:22:50.933 SERIAL « 0x0104011301e8 (6 bytes) 17:22:50.933 SERIAL » [ACK] (0x06) 17:22:50.934 DRIVER « [RES] [SendData] was sent: true 17:22:50.949 SERIAL « 0x010700138800000360 (9 bytes) 17:22:50.950 SERIAL » [ACK] (0x06) 17:22:50.951 DRIVER « [REQ] [SendData] callback id: 136 transmit status: OK 17:22:50.960 SERIAL « 0x010c000400190670060402000098 (14 bytes) 17:22:50.965 CNTRLR [Node 025] [~] [Configuration] 4: 0 => 0 17:22:50.966 SERIAL » [ACK] (0x06) 17:22:50.979 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 2 value: 0 17:22:50.982 SERIAL » 0x010a0013130370051d258932 (12 bytes) 17:22:50.982 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 137 └─[ConfigurationCCGet] parameter #: 29 17:22:50.983 CNTRLR « [Node 025] parameter #4 has value: 0 17:22:50.983 CNTRLR » [Node 025] querying parameter #5 value... 17:22:50.986 SERIAL « [ACK] (0x06) 17:22:50.991 SERIAL « 0x0104011301e8 (6 bytes) 17:22:50.992 SERIAL » [ACK] (0x06) 17:22:50.993 DRIVER « [RES] [SendData] was sent: true 17:22:51.008 SERIAL « 0x010700138900000260 (9 bytes) 17:22:51.008 SERIAL » [ACK] (0x06) 17:22:51.009 DRIVER « [REQ] [SendData] callback id: 137 transmit status: OK 17:22:51.018 SERIAL « 0x010b000400130570061d01008c (13 bytes) 17:22:51.024 CNTRLR [Node 019] [~] [Configuration] 29: 0 => 0 17:22:51.024 SERIAL » [ACK] (0x06) 17:22:51.025 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 29 value size: 1 value: 0 17:22:51.029 SERIAL » 0x010a00131a0370050c258a29 (12 bytes) 17:22:51.029 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 138 └─[ConfigurationCCGet] parameter #: 12 17:22:51.029 CNTRLR « [Node 019] parameter #29 has value: 0 17:22:51.030 CNTRLR » [Node 019] querying parameter #30 value... 17:22:51.033 SERIAL « [ACK] (0x06) 17:22:51.037 SERIAL « 0x0104011301e8 (6 bytes) 17:22:51.038 SERIAL » [ACK] (0x06) 17:22:51.038 DRIVER « [RES] [SendData] was sent: true 17:22:51.075 SERIAL « 0x010700138a00000465 (9 bytes) 17:22:51.076 SERIAL » [ACK] (0x06) 17:22:51.076 DRIVER « [REQ] [SendData] callback id: 138 transmit status: OK 17:22:51.124 SERIAL « 0x010c0004001a0670060c02009605 (14 bytes) 17:22:51.131 CNTRLR [Node 026] [~] [Configuration] 12: 150 => 150 17:22:51.132 SERIAL » [ACK] (0x06) 17:22:51.133 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 150 17:22:51.136 SERIAL » 0x010d00131606600d00018002258bb1 (15 bytes) 17:22:51.137 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 139 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BatteryCCGet] 17:22:51.137 CNTRLR « [Node 026] parameter #12 has value: 150 17:22:51.137 CNTRLR » [Node 026] querying parameter #13 value... 17:22:51.141 SERIAL « [ACK] (0x06) 17:22:51.149 SERIAL « 0x0104011301e8 (6 bytes) 17:22:51.149 SERIAL » [ACK] (0x06) 17:22:51.150 DRIVER « [RES] [SendData] was sent: true 17:22:51.209 SERIAL « 0x010700138b00000767 (9 bytes) 17:22:51.210 SERIAL » [ACK] (0x06) 17:22:51.210 DRIVER « [REQ] [SendData] callback id: 139 transmit status: OK 17:22:51.296 SERIAL « 0x010d0004001607600d01008003636b (15 bytes) 17:22:51.297 CNTRLR [Node 022] [~] [Battery] level: 99 => 99 [Endpoint 1] 17:22:51.297 CNTRLR [Node 022] [~] [Battery] isLow: false => false [Endpoint 1] 17:22:51.298 SERIAL » [ACK] (0x06) 17:22:51.299 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BatteryCCReport] level: 99 is low: false 17:22:51.302 SERIAL » 0x010a00131703700505258c2b (12 bytes) 17:22:51.303 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 140 └─[ConfigurationCCGet] parameter #: 5 17:22:51.303 CNTRLR « [Node 022] received response for battery information: [Endpoint 1] level: 99 17:22:51.303 CNTRLR [Node 022] [~] [Battery] interviewComplete: true => tr [Endpoint 1] [internal] ue 17:22:51.304 CNTRLR [Node 022] ClockCC: doing a partial interview... 17:22:51.304 CNTRLR » [Node 022] requesting current clock setting... 17:22:51.328 SERIAL « [ACK] (0x06) 17:22:51.330 SERIAL « 0x0104011301e8 (6 bytes) 17:22:51.332 SERIAL » [ACK] (0x06) 17:22:51.332 DRIVER « [RES] [SendData] was sent: true 17:22:51.339 SERIAL « 0x010700138c00000265 (9 bytes) 17:22:51.339 SERIAL » [ACK] (0x06) 17:22:51.340 DRIVER « [REQ] [SendData] callback id: 140 transmit status: OK 17:22:51.342 SERIAL « 0x010c000400170670060502000097 (14 bytes) 17:22:51.347 CNTRLR [Node 023] [~] [Configuration] 5: 0 => 0 17:22:51.348 SERIAL » [ACK] (0x06) 17:22:51.349 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 2 value: 0 17:22:51.352 SERIAL » 0x010a00131803320100258d66 (12 bytes) 17:22:51.353 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 141 └─[MeterCCGet] duration: kWh 17:22:51.353 CNTRLR « [Node 023] parameter #5 has value: 0 17:22:51.353 CNTRLR » [Node 023] querying parameter #6 value... 17:22:51.357 SERIAL « [ACK] (0x06) 17:22:51.362 SERIAL « 0x0104011301e8 (6 bytes) 17:22:51.362 SERIAL » [ACK] (0x06) 17:22:51.363 DRIVER « [RES] [SendData] was sent: true 17:22:51.381 SERIAL « 0x010700138d00000365 (9 bytes) 17:22:51.382 SERIAL » [ACK] (0x06) 17:22:51.382 DRIVER « [REQ] [SendData] callback id: 141 transmit status: OK 17:22:51.397 SERIAL « 0x0110000400180a32022144000001bf000012 (18 bytes) 17:22:51.398 CNTRLR [Node 024] [~] [Meter] value[65537]: 4.47 => 4.47 [Endpoint 0] 17:22:51.398 CNTRLR [Node 024] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 17:22:51.399 SERIAL » [ACK] (0x06) 17:22:51.399 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 4.47 time delta: 0 seconds 17:22:51.403 SERIAL » 0x010a00131903700505258e27 (12 bytes) 17:22:51.403 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 142 └─[ConfigurationCCGet] parameter #: 5 17:22:51.404 CNTRLR » [Node 024] querying meter value (type = Electric, scale = W)... 17:22:51.409 SERIAL « [ACK] (0x06) 17:22:51.411 SERIAL « 0x0104011301e8 (6 bytes) 17:22:51.412 SERIAL » [ACK] (0x06) 17:22:51.412 DRIVER « [RES] [SendData] was sent: true 17:22:51.429 SERIAL « 0x010700138e00000366 (9 bytes) 17:22:51.429 SERIAL » [ACK] (0x06) 17:22:51.430 DRIVER « [REQ] [SendData] callback id: 142 transmit status: OK 17:22:51.439 SERIAL « 0x010c000400190670060502000099 (14 bytes) 17:22:51.445 CNTRLR [Node 025] [~] [Configuration] 5: 0 => 0 17:22:51.445 SERIAL » [ACK] (0x06) 17:22:51.446 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 2 value: 0 17:22:51.449 SERIAL » 0x010a0013130370051e258f37 (12 bytes) 17:22:51.449 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 143 └─[ConfigurationCCGet] parameter #: 30 17:22:51.450 CNTRLR « [Node 025] parameter #5 has value: 0 17:22:51.450 CNTRLR » [Node 025] querying parameter #6 value... 17:22:51.454 SERIAL « [ACK] (0x06) 17:22:51.461 SERIAL « 0x0104011301e8 (6 bytes) 17:22:51.461 SERIAL » [ACK] (0x06) 17:22:51.462 DRIVER « [RES] [SendData] was sent: true 17:22:51.475 SERIAL « 0x010700138f00000266 (9 bytes) 17:22:51.475 SERIAL » [ACK] (0x06) 17:22:51.475 DRIVER « [REQ] [SendData] callback id: 143 transmit status: OK 17:22:51.486 SERIAL « 0x010b000400130570061e01028d (13 bytes) 17:22:51.491 CNTRLR [Node 019] [~] [Configuration] 30: 2 => 2 17:22:51.491 SERIAL » [ACK] (0x06) 17:22:51.492 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 2 17:22:51.495 SERIAL » 0x010a00131a0370050d259032 (12 bytes) 17:22:51.496 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 144 └─[ConfigurationCCGet] parameter #: 13 17:22:51.497 CNTRLR « [Node 019] parameter #30 has value: 2 17:22:51.497 CNTRLR » [Node 019] querying parameter #31 value... 17:22:51.500 SERIAL « [ACK] (0x06) 17:22:51.504 SERIAL « 0x0104011301e8 (6 bytes) 17:22:51.505 SERIAL » [ACK] (0x06) 17:22:51.505 DRIVER « [RES] [SendData] was sent: true 17:22:51.543 SERIAL « 0x01070013900000047f (9 bytes) 17:22:51.543 SERIAL » [ACK] (0x06) 17:22:51.543 DRIVER « [REQ] [SendData] callback id: 144 transmit status: OK 17:22:51.592 SERIAL « 0x010b0004001a0570060d010194 (13 bytes) 17:22:51.598 CNTRLR [Node 026] [~] [Configuration] 13: 1 => 1 17:22:51.598 SERIAL » [ACK] (0x06) 17:22:51.599 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 1 17:22:51.607 SERIAL » 0x010d00131606600d000181052591ad (15 bytes) 17:22:51.608 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 145 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ClockCCGet] 17:22:51.615 CNTRLR « [Node 026] parameter #13 has value: 1 17:22:51.615 CNTRLR » [Node 026] querying parameter #14 value... 17:22:51.619 SERIAL « [ACK] (0x06) 17:22:51.624 SERIAL « 0x0104011301e8 (6 bytes) 17:22:51.625 SERIAL » [ACK] (0x06) 17:22:51.626 DRIVER « [RES] [SendData] was sent: true 17:22:51.679 SERIAL « 0x01070013910000077d (9 bytes) 17:22:51.680 SERIAL » [ACK] (0x06) 17:22:51.681 DRIVER « [REQ] [SendData] callback id: 145 transmit status: OK 17:22:51.767 SERIAL « 0x010e0004001608600d01008106720d7f (16 bytes) 17:22:51.769 SERIAL » [ACK] (0x06) 17:22:51.770 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ClockCCReport] clock setting: Wednesday, 18:13 17:22:51.775 SERIAL » 0x010a00131703700506259236 (12 bytes) 17:22:51.776 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 146 └─[ConfigurationCCGet] parameter #: 6 17:22:51.777 CNTRLR « [Node 022] received current clock setting: Wednesday, 18:13 17:22:51.777 CNTRLR [Node 022] [~] [Clock] interviewComplete: true => true [Endpoint 1] [internal] 17:22:51.781 CNTRLR [Node 022] ZWavePlusCC: doing a partial interview... [Endpoint 2] 17:22:51.782 CNTRLR [Node 022] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 17:22:51.782 CNTRLR [Node 022] MultilevelSensorCC: doing a partial interview... [Endpoint 2] 17:22:51.783 CNTRLR » [Node 022] querying Air temperature sensor reading... [Endpoint 2] 17:22:51.789 SERIAL « [ACK] (0x06) 17:22:51.790 SERIAL « 0x0104011301e8 (6 bytes) 17:22:51.791 SERIAL » [ACK] (0x06) 17:22:51.791 DRIVER « [RES] [SendData] was sent: true 17:22:51.802 SERIAL « 0x01070013920000027b (9 bytes) 17:22:51.803 SERIAL » [ACK] (0x06) 17:22:51.803 DRIVER « [REQ] [SendData] callback id: 146 transmit status: OK 17:22:51.812 SERIAL « 0x010b0004001705700606010093 (13 bytes) 17:22:51.822 CNTRLR [Node 023] [~] [Configuration] 6: 0 => 0 17:22:51.823 SERIAL » [ACK] (0x06) 17:22:51.825 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 1 value: 0 17:22:51.830 SERIAL » 0x010a00131803320110259368 (12 bytes) 17:22:51.831 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 147 └─[MeterCCGet] duration: W 17:22:51.832 CNTRLR « [Node 023] parameter #6 has value: 0 17:22:51.832 CNTRLR » [Node 023] querying parameter #7 value... 17:22:51.838 SERIAL « [ACK] (0x06) 17:22:51.841 SERIAL « 0x0104011301e8 (6 bytes) 17:22:51.841 SERIAL » [ACK] (0x06) 17:22:51.842 DRIVER « [RES] [SendData] was sent: true 17:22:51.860 SERIAL « 0x01070013930000037b (9 bytes) 17:22:51.861 SERIAL » [ACK] (0x06) 17:22:51.861 DRIVER « [REQ] [SendData] callback id: 147 transmit status: OK 17:22:51.875 SERIAL « 0x010e00040018083202213200000000c6 (16 bytes) 17:22:51.876 CNTRLR [Node 024] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 17:22:51.876 CNTRLR [Node 024] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 17:22:51.876 SERIAL » [ACK] (0x06) 17:22:51.877 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 17:22:51.880 SERIAL » 0x010a0013190370050625943e (12 bytes) 17:22:51.881 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 148 └─[ConfigurationCCGet] parameter #: 6 17:22:51.881 CNTRLR [Node 024] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 17:22:51.881 CNTRLR [Node 024] ConfigurationCC: Loading configuration parameters from device confi g 17:22:51.888 CNTRLR [Node 024] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:22:51.889 CNTRLR [Node 024] [Configuration] 9: metadata updated 17:22:51.890 CNTRLR [Node 024] [Configuration] 10: metadata updated 17:22:51.891 CNTRLR [Node 024] [Configuration] 11: metadata updated 17:22:51.892 CNTRLR [Node 024] [Configuration] 12: metadata updated 17:22:51.893 CNTRLR [Node 024] [Configuration] 13: metadata updated 17:22:51.894 CNTRLR [Node 024] [Configuration] 15: metadata updated 17:22:51.895 CNTRLR [Node 024] [Configuration] 16: metadata updated 17:22:51.896 CNTRLR [Node 024] [Configuration] 17: metadata updated 17:22:51.897 CNTRLR [Node 024] [Configuration] 18: metadata updated 17:22:51.898 CNTRLR [Node 024] [Configuration] 20: metadata updated 17:22:51.900 CNTRLR [Node 024] [Configuration] 21: metadata updated 17:22:51.901 CNTRLR [Node 024] [Configuration] 27: metadata updated 17:22:51.902 CNTRLR [Node 024] [Configuration] 28: metadata updated 17:22:51.903 CNTRLR [Node 024] [Configuration] 29: metadata updated 17:22:51.904 CNTRLR [Node 024] [Configuration] 30: metadata updated 17:22:51.905 CNTRLR [Node 024] [Configuration] 31: metadata updated 17:22:51.906 CNTRLR [Node 024] [Configuration] 32: metadata updated 17:22:51.907 CNTRLR [Node 024] [Configuration] 33: metadata updated 17:22:51.909 CNTRLR [Node 024] [Configuration] 35: metadata updated 17:22:51.910 CNTRLR [Node 024] [Configuration] 36: metadata updated 17:22:51.911 CNTRLR [Node 024] [Configuration] 37: metadata updated 17:22:51.912 CNTRLR [Node 024] [Configuration] 38: metadata updated 17:22:51.913 CNTRLR [Node 024] [Configuration] 40: metadata updated 17:22:51.915 CNTRLR [Node 024] [Configuration] 41: metadata updated 17:22:51.916 CNTRLR [Node 024] [Configuration] 42: metadata updated 17:22:51.917 CNTRLR [Node 024] [Configuration] 43: metadata updated 17:22:51.918 CNTRLR [Node 024] [Configuration] 44: metadata updated 17:22:51.920 CNTRLR [Node 024] [Configuration] 50: metadata updated 17:22:51.921 CNTRLR [Node 024] [Configuration] 51: metadata updated 17:22:51.922 CNTRLR [Node 024] [Configuration] 53: metadata updated 17:22:51.923 CNTRLR [Node 024] [Configuration] 54: metadata updated 17:22:51.924 CNTRLR [Node 024] [Configuration] 55: metadata updated 17:22:51.925 CNTRLR [Node 024] [Configuration] 57: metadata updated 17:22:51.926 CNTRLR [Node 024] [Configuration] 58: metadata updated 17:22:51.927 CNTRLR [Node 024] [Configuration] 59: metadata updated 17:22:51.928 CNTRLR [Node 024] [Configuration] 60: metadata updated 17:22:51.929 CNTRLR [Node 024] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:22:51.929 CNTRLR » [Node 024] querying parameter #9 value... 17:22:51.937 SERIAL « [ACK] (0x06) 17:22:51.939 SERIAL « 0x0104011301e8 (6 bytes) 17:22:51.940 SERIAL » [ACK] (0x06) 17:22:51.959 DRIVER « [RES] [SendData] was sent: true 17:22:51.971 SERIAL « 0x01070013940000027d (9 bytes) 17:22:51.972 SERIAL » [ACK] (0x06) 17:22:51.973 DRIVER « [REQ] [SendData] callback id: 148 transmit status: OK 17:22:51.978 SERIAL « 0x010b000400190570060601009d (13 bytes) 17:22:51.989 CNTRLR [Node 025] [~] [Configuration] 6: 0 => 0 17:22:51.990 SERIAL » [ACK] (0x06) 17:22:51.992 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 1 value: 0 17:22:51.997 SERIAL » 0x010a0013130370051f25952c (12 bytes) 17:22:51.997 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 149 └─[ConfigurationCCGet] parameter #: 31 17:22:51.998 CNTRLR « [Node 025] parameter #6 has value: 0 17:22:51.998 CNTRLR » [Node 025] querying parameter #7 value... 17:22:52.009 SERIAL « 0x010c000400030631050422098b62 (14 bytes) 17:22:52.010 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:22:52.011 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 129.8 => 244.3 [Endpoint 0] 17:22:52.012 SERIAL » [ACK] (0x06) 17:22:52.012 SERIAL « [CAN] (0x18) 17:22:52.013 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 17:22:52.016 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 244.3 17:22:52.113 SERIAL » 0x010a0013130370051f25952c (12 bytes) 17:22:52.114 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 149 └─[ConfigurationCCGet] parameter #: 31 17:22:52.115 SERIAL « [ACK] (0x06) 17:22:52.121 SERIAL « 0x0104011301e8 (6 bytes) 17:22:52.122 SERIAL » [ACK] (0x06) 17:22:52.122 DRIVER « [RES] [SendData] was sent: true 17:22:52.139 SERIAL « 0x01070013950000037d (9 bytes) 17:22:52.139 SERIAL » [ACK] (0x06) 17:22:52.140 DRIVER « [REQ] [SendData] callback id: 149 transmit status: OK 17:22:52.149 SERIAL « 0x010b000400130570061f01008e (13 bytes) 17:22:52.155 CNTRLR [Node 019] [~] [Configuration] 31: 0 => 0 17:22:52.156 SERIAL » [ACK] (0x06) 17:22:52.157 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 0 17:22:52.160 SERIAL » 0x010a00131a0370050e259637 (12 bytes) 17:22:52.161 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 150 └─[ConfigurationCCGet] parameter #: 14 17:22:52.161 CNTRLR « [Node 019] parameter #31 has value: 0 17:22:52.161 CNTRLR » [Node 019] querying parameter #32 value... 17:22:52.172 SERIAL « [ACK] (0x06) 17:22:52.173 SERIAL « 0x0104011301e8 (6 bytes) 17:22:52.174 SERIAL » [ACK] (0x06) 17:22:52.175 DRIVER « [RES] [SendData] was sent: true 17:22:52.207 SERIAL « 0x010700139600000479 (9 bytes) 17:22:52.207 SERIAL » [ACK] (0x06) 17:22:52.208 DRIVER « [REQ] [SendData] callback id: 150 transmit status: OK 17:22:52.257 SERIAL « 0x010b0004001a0570060e010096 (13 bytes) 17:22:52.262 CNTRLR [Node 026] [~] [Configuration] 14: 0 => 0 17:22:52.263 SERIAL » [ACK] (0x06) 17:22:52.264 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 0 17:22:52.267 SERIAL » 0x010f00131608600d000231040100259714 (17 bytes) 17:22:52.268 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 151 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 17:22:52.268 CNTRLR « [Node 026] parameter #14 has value: 0 17:22:52.268 CNTRLR » [Node 026] querying parameter #17 value... 17:22:52.271 SERIAL « [ACK] (0x06) 17:22:52.277 SERIAL « 0x0104011301e8 (6 bytes) 17:22:52.277 SERIAL » [ACK] (0x06) 17:22:52.279 DRIVER « [RES] [SendData] was sent: true 17:22:52.350 SERIAL « 0x010700139700000874 (9 bytes) 17:22:52.350 SERIAL » [ACK] (0x06) 17:22:52.350 DRIVER « [REQ] [SendData] callback id: 151 transmit status: OK 17:22:52.443 SERIAL « 0x0110000400160a600d020031050122009e11 (18 bytes) 17:22:52.444 CNTRLR [Node 022] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 17:22:52.445 CNTRLR [Node 022] [~] [Multilevel Sensor] Air temperature: 15.8 => 15.8 [Endpoint 2] 17:22:52.445 SERIAL » [ACK] (0x06) 17:22:52.446 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 15.8 17:22:52.449 SERIAL » 0x010a0013170370050725983d (12 bytes) 17:22:52.450 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 152 └─[ConfigurationCCGet] parameter #: 7 17:22:52.450 CNTRLR « [Node 022] received current Air temperature sensor reading: 15.8 [Endpoint 2] °C 17:22:52.450 CNTRLR [Node 022] [~] [Multilevel Sensor] interviewComplete: [Endpoint 2] [internal] true => true 17:22:52.477 SERIAL « [ACK] (0x06) 17:22:52.481 SERIAL « 0x0104011301e8 (6 bytes) 17:22:52.481 SERIAL » [ACK] (0x06) 17:22:52.483 DRIVER « [RES] [SendData] was sent: true 17:22:52.485 CNTRLR [Node 022] NotificationCC: doing a partial interview... [Endpoint 2] 17:22:52.485 CNTRLR [Node 022] [~] [Notification] interviewComplete: true [Endpoint 2] [internal] => true 17:22:52.486 CNTRLR [Node 022] BatteryCC: doing a partial interview... [Endpoint 2] 17:22:52.486 CNTRLR » [Node 022] querying battery status... [Endpoint 2] 17:22:52.488 SERIAL « 0x010700139800000271 (9 bytes) 17:22:52.489 SERIAL » [ACK] (0x06) 17:22:52.489 DRIVER « [REQ] [SendData] callback id: 152 transmit status: OK 17:22:52.491 SERIAL « 0x010b0004001705700607010092 (13 bytes) 17:22:52.496 CNTRLR [Node 023] [~] [Configuration] 7: 0 => 0 17:22:52.497 SERIAL » [ACK] (0x06) 17:22:52.498 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 7 value size: 1 value: 0 17:22:52.501 SERIAL » 0x010a0013180370050925993d (12 bytes) 17:22:52.501 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 153 └─[ConfigurationCCGet] parameter #: 9 17:22:52.502 CNTRLR « [Node 023] parameter #7 has value: 0 17:22:52.502 CNTRLR » [Node 023] querying parameter #13 value... 17:22:52.506 SERIAL « [ACK] (0x06) 17:22:52.510 SERIAL « 0x0104011301e8 (6 bytes) 17:22:52.510 SERIAL » [ACK] (0x06) 17:22:52.511 DRIVER « [RES] [SendData] was sent: true 17:22:52.530 SERIAL « 0x010700139900000371 (9 bytes) 17:22:52.530 SERIAL » [ACK] (0x06) 17:22:52.531 DRIVER « [REQ] [SendData] callback id: 153 transmit status: OK 17:22:52.544 SERIAL « 0x010b0004001805700609010192 (13 bytes) 17:22:52.549 CNTRLR [Node 024] [~] [Configuration] 9: 1 => 1 17:22:52.550 SERIAL » [ACK] (0x06) 17:22:52.551 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 1 value: 1 17:22:52.554 SERIAL » 0x010a00131903700507259a31 (12 bytes) 17:22:52.554 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 154 └─[ConfigurationCCGet] parameter #: 7 17:22:52.555 CNTRLR « [Node 024] parameter #9 has value: 1 17:22:52.555 CNTRLR » [Node 024] querying parameter #10 value... 17:22:52.558 SERIAL « [ACK] (0x06) 17:22:52.562 SERIAL « 0x0104011301e8 (6 bytes) 17:22:52.563 SERIAL » [ACK] (0x06) 17:22:52.563 DRIVER « [RES] [SendData] was sent: true 17:22:52.580 SERIAL « 0x010700139a00000372 (9 bytes) 17:22:52.581 SERIAL » [ACK] (0x06) 17:22:52.581 DRIVER « [REQ] [SendData] callback id: 154 transmit status: OK 17:22:52.590 SERIAL « 0x010b000400190570060701009c (13 bytes) 17:22:52.598 CNTRLR [Node 025] [~] [Configuration] 7: 0 => 0 17:22:52.599 SERIAL » [ACK] (0x06) 17:22:52.600 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 7 value size: 1 value: 0 17:22:52.604 SERIAL » 0x010a00131303700520259b1d (12 bytes) 17:22:52.605 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 155 └─[ConfigurationCCGet] parameter #: 32 17:22:52.605 CNTRLR « [Node 025] parameter #7 has value: 0 17:22:52.605 CNTRLR » [Node 025] querying parameter #13 value... 17:22:52.609 SERIAL « [ACK] (0x06) 17:22:52.613 SERIAL « 0x0104011301e8 (6 bytes) 17:22:52.614 SERIAL » [ACK] (0x06) 17:22:52.615 DRIVER « [RES] [SendData] was sent: true 17:22:52.630 SERIAL « 0x010700139b00000373 (9 bytes) 17:22:52.630 SERIAL » [ACK] (0x06) 17:22:52.631 DRIVER « [REQ] [SendData] callback id: 155 transmit status: OK 17:22:52.674 SERIAL « 0x010b00040013057006200101b0 (13 bytes) 17:22:52.679 CNTRLR [Node 019] [~] [Configuration] 32: 1 => 1 17:22:52.680 SERIAL » [ACK] (0x06) 17:22:52.682 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 1 value: 1 17:22:52.685 SERIAL » 0x010a00131a03700511259c22 (12 bytes) 17:22:52.685 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 156 └─[ConfigurationCCGet] parameter #: 17 17:22:52.686 CNTRLR « [Node 019] parameter #32 has value: 1 17:22:52.686 CNTRLR » [Node 019] querying parameter #33 value... 17:22:52.689 SERIAL « [ACK] (0x06) 17:22:52.693 SERIAL « 0x0104011301e8 (6 bytes) 17:22:52.694 SERIAL » [ACK] (0x06) 17:22:52.695 DRIVER « [RES] [SendData] was sent: true 17:22:52.735 SERIAL « 0x010700139c00000572 (9 bytes) 17:22:52.736 SERIAL » [ACK] (0x06) 17:22:52.740 DRIVER « [REQ] [SendData] callback id: 156 transmit status: OK 17:22:52.784 SERIAL « 0x010b0004001a05700611010a83 (13 bytes) 17:22:52.789 CNTRLR [Node 026] [~] [Configuration] 17: 10 => 10 17:22:52.790 SERIAL » [ACK] (0x06) 17:22:52.791 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 17 value size: 1 value: 10 17:22:52.794 SERIAL » 0x010d00131606600d00028002259da4 (15 bytes) 17:22:52.794 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 157 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[BatteryCCGet] 17:22:52.795 CNTRLR « [Node 026] parameter #17 has value: 10 17:22:52.795 CNTRLR » [Node 026] querying parameter #18 value... 17:22:52.798 SERIAL « [ACK] (0x06) 17:22:52.804 SERIAL « 0x0104011301e8 (6 bytes) 17:22:52.804 SERIAL » [ACK] (0x06) 17:22:52.805 DRIVER « [RES] [SendData] was sent: true 17:22:52.869 SERIAL « 0x010700139d0000087e (9 bytes) 17:22:52.870 SERIAL » [ACK] (0x06) 17:22:52.870 DRIVER « [REQ] [SendData] callback id: 157 transmit status: OK 17:22:52.955 SERIAL « 0x010d0004001607600d02008003515a (15 bytes) 17:22:52.956 CNTRLR [Node 022] [~] [Battery] level: 81 => 81 [Endpoint 2] 17:22:52.957 CNTRLR [Node 022] [~] [Battery] isLow: false => false [Endpoint 2] 17:22:52.957 SERIAL » [ACK] (0x06) 17:22:52.958 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BatteryCCReport] level: 81 is low: false 17:22:52.961 SERIAL » 0x010a0013170370050d259e31 (12 bytes) 17:22:52.962 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 158 └─[ConfigurationCCGet] parameter #: 13 17:22:52.962 CNTRLR « [Node 022] received response for battery information: [Endpoint 2] level: 81 17:22:52.962 CNTRLR [Node 022] [~] [Battery] interviewComplete: true => tr [Endpoint 2] [internal] ue 17:22:52.990 SERIAL « [ACK] (0x06) 17:22:52.994 SERIAL « 0x0104011301e8 (6 bytes) 17:22:52.994 SERIAL » [ACK] (0x06) 17:22:52.996 DRIVER « [RES] [SendData] was sent: true 17:22:52.998 CNTRLR [Node 022] MultilevelSensorCC: doing a partial interview... 17:22:52.998 CNTRLR » [Node 022] querying Air temperature sensor reading... 17:22:53.001 SERIAL « 0x010700139e00000277 (9 bytes) 17:22:53.001 SERIAL » [ACK] (0x06) 17:22:53.001 DRIVER « [REQ] [SendData] callback id: 158 transmit status: OK 17:22:53.003 SERIAL « 0x010b000400170570060d010098 (13 bytes) 17:22:53.009 CNTRLR [Node 023] [~] [Configuration] 13: 0 => 0 17:22:53.009 SERIAL » [ACK] (0x06) 17:22:53.010 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 0 17:22:53.013 SERIAL » 0x010a0013180370050a259f38 (12 bytes) 17:22:53.014 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 159 └─[ConfigurationCCGet] parameter #: 10 17:22:53.014 CNTRLR « [Node 023] parameter #13 has value: 0 17:22:53.014 CNTRLR » [Node 023] querying parameter #14 value... 17:22:53.017 SERIAL « [ACK] (0x06) 17:22:53.023 SERIAL « 0x0104011301e8 (6 bytes) 17:22:53.024 SERIAL » [ACK] (0x06) 17:22:53.026 DRIVER « [RES] [SendData] was sent: true 17:22:53.042 SERIAL « 0x010700139f00000377 (9 bytes) 17:22:53.043 SERIAL » [ACK] (0x06) 17:22:53.043 DRIVER « [REQ] [SendData] callback id: 159 transmit status: OK 17:22:53.056 SERIAL « 0x010b000400180570060a010090 (13 bytes) 17:22:53.061 CNTRLR [Node 024] [~] [Configuration] 10: 0 => 0 17:22:53.063 SERIAL » [ACK] (0x06) 17:22:53.063 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 0 17:22:53.066 SERIAL » 0x010a0013190370050d25a001 (12 bytes) 17:22:53.067 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 160 └─[ConfigurationCCGet] parameter #: 13 17:22:53.067 CNTRLR « [Node 024] parameter #10 has value: 0 17:22:53.067 CNTRLR » [Node 024] querying parameter #11 value... 17:22:53.075 SERIAL « [ACK] (0x06) 17:22:53.077 SERIAL « 0x0104011301e8 (6 bytes) 17:22:53.077 SERIAL » [ACK] (0x06) 17:22:53.078 DRIVER « [RES] [SendData] was sent: true 17:22:53.092 SERIAL « 0x01070013a000000249 (9 bytes) 17:22:53.092 SERIAL » [ACK] (0x06) 17:22:53.093 DRIVER « [REQ] [SendData] callback id: 160 transmit status: OK 17:22:53.102 SERIAL « 0x010b000400190570060d010096 (13 bytes) 17:22:53.108 CNTRLR [Node 025] [~] [Configuration] 13: 0 => 0 17:22:53.108 SERIAL » [ACK] (0x06) 17:22:53.109 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 0 17:22:53.112 SERIAL » 0x010a0013130370052125a126 (12 bytes) 17:22:53.113 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 161 └─[ConfigurationCCGet] parameter #: 33 17:22:53.113 CNTRLR « [Node 025] parameter #13 has value: 0 17:22:53.113 CNTRLR » [Node 025] querying parameter #14 value... 17:22:53.120 SERIAL « [ACK] (0x06) 17:22:53.121 SERIAL « 0x0104011301e8 (6 bytes) 17:22:53.122 SERIAL » [ACK] (0x06) 17:22:53.126 DRIVER « [RES] [SendData] was sent: true 17:22:53.138 SERIAL « 0x01070013a100000248 (9 bytes) 17:22:53.138 SERIAL » [ACK] (0x06) 17:22:53.139 DRIVER « [REQ] [SendData] callback id: 161 transmit status: OK 17:22:53.148 SERIAL « 0x010b00040013057006210101b1 (13 bytes) 17:22:53.153 CNTRLR [Node 019] [~] [Configuration] 33: 1 => 1 17:22:53.154 SERIAL » [ACK] (0x06) 17:22:53.155 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 1 value: 1 17:22:53.158 SERIAL » 0x010a00131a0370051225a21f (12 bytes) 17:22:53.159 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 162 └─[ConfigurationCCGet] parameter #: 18 17:22:53.159 CNTRLR « [Node 019] parameter #33 has value: 1 17:22:53.159 CNTRLR » [Node 019] querying parameter #35 value... 17:22:53.165 SERIAL « [ACK] (0x06) 17:22:53.169 SERIAL « 0x0104011301e8 (6 bytes) 17:22:53.170 SERIAL » [ACK] (0x06) 17:22:53.172 DRIVER « [RES] [SendData] was sent: true 17:22:53.205 SERIAL « 0x01070013a20000044d (9 bytes) 17:22:53.205 SERIAL » [ACK] (0x06) 17:22:53.206 DRIVER « [REQ] [SendData] callback id: 162 transmit status: OK 17:22:53.254 SERIAL « 0x010b0004001a05700612010a80 (13 bytes) 17:22:53.259 CNTRLR [Node 026] [~] [Configuration] 18: 10 => 10 17:22:53.260 SERIAL » [ACK] (0x06) 17:22:53.260 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 18 value size: 1 value: 10 17:22:53.268 SERIAL » 0x010b001316043104010025a347 (13 bytes) 17:22:53.268 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 163 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 17:22:53.269 CNTRLR « [Node 026] parameter #18 has value: 10 17:22:53.269 CNTRLR » [Node 026] querying parameter #22 value... 17:22:53.279 SERIAL « [ACK] (0x06) 17:22:53.281 SERIAL « 0x0104011301e8 (6 bytes) 17:22:53.281 SERIAL » [ACK] (0x06) 17:22:53.282 DRIVER « [RES] [SendData] was sent: true 17:22:53.339 SERIAL « 0x01070013a30000074f (9 bytes) 17:22:53.339 SERIAL » [ACK] (0x06) 17:22:53.339 DRIVER « [REQ] [SendData] callback id: 163 transmit status: OK 17:22:53.431 SERIAL « 0x010c000400160631050122009e6e (14 bytes) 17:22:53.432 CNTRLR [Node 022] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 17:22:53.433 CNTRLR [Node 022] [~] [Multilevel Sensor] Air temperature: 18.7 => 15.8 [Endpoint 0] 17:22:53.433 SERIAL » [ACK] (0x06) 17:22:53.435 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 15.8 17:22:53.440 SERIAL » 0x010a0013170370050e25a408 (12 bytes) 17:22:53.440 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 164 └─[ConfigurationCCGet] parameter #: 14 17:22:53.441 CNTRLR « [Node 022] received current Air temperature sensor reading: 15.8 °C 17:22:53.442 CNTRLR [Node 022] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 17:22:53.499 SERIAL « [ACK] (0x06) 17:22:53.503 SERIAL « 0x0104011301e8 (6 bytes) 17:22:53.503 SERIAL » [ACK] (0x06) 17:22:53.504 DRIVER « [RES] [SendData] was sent: true 17:22:53.506 CNTRLR [Node 022] ThermostatModeCC: doing a partial interview... 17:22:53.506 CNTRLR » [Node 022] querying current thermostat mode... 17:22:53.508 SERIAL « 0x01070013a40000024d (9 bytes) 17:22:53.509 SERIAL » [ACK] (0x06) 17:22:53.509 DRIVER « [REQ] [SendData] callback id: 164 transmit status: OK 17:22:53.511 SERIAL « 0x010b000400170570060e01019a (13 bytes) 17:22:53.517 CNTRLR [Node 023] [~] [Configuration] 14: 1 => 1 17:22:53.517 SERIAL » [ACK] (0x06) 17:22:53.518 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 1 17:22:53.521 SERIAL » 0x010a0013180370050b25a503 (12 bytes) 17:22:53.522 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 165 └─[ConfigurationCCGet] parameter #: 11 17:22:53.522 CNTRLR « [Node 023] parameter #14 has value: 1 17:22:53.522 CNTRLR » [Node 023] querying parameter #15 value... 17:22:53.526 SERIAL « [ACK] (0x06) 17:22:53.530 SERIAL « 0x0104011301e8 (6 bytes) 17:22:53.530 SERIAL » [ACK] (0x06) 17:22:53.531 DRIVER « [RES] [SendData] was sent: true 17:22:53.550 SERIAL « 0x01070013a50000034d (9 bytes) 17:22:53.551 SERIAL » [ACK] (0x06) 17:22:53.551 DRIVER « [REQ] [SendData] callback id: 165 transmit status: OK 17:22:53.564 SERIAL « 0x010b000400180570060b010091 (13 bytes) 17:22:53.570 CNTRLR [Node 024] [~] [Configuration] 11: 0 => 0 17:22:53.570 SERIAL » [ACK] (0x06) 17:22:53.571 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 11 value size: 1 value: 0 17:22:53.574 SERIAL » 0x010a0013190370050e25a604 (12 bytes) 17:22:53.575 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 166 └─[ConfigurationCCGet] parameter #: 14 17:22:53.575 CNTRLR « [Node 024] parameter #11 has value: 0 17:22:53.575 CNTRLR » [Node 024] querying parameter #12 value... 17:22:53.579 SERIAL « [ACK] (0x06) 17:22:53.583 SERIAL « 0x0104011301e8 (6 bytes) 17:22:53.583 SERIAL » [ACK] (0x06) 17:22:53.584 DRIVER « [RES] [SendData] was sent: true 17:22:53.601 SERIAL « 0x01070013a60000034e (9 bytes) 17:22:53.601 SERIAL » [ACK] (0x06) 17:22:53.602 DRIVER « [REQ] [SendData] callback id: 166 transmit status: OK 17:22:53.611 SERIAL « 0x010b000400190570060e010194 (13 bytes) 17:22:53.616 CNTRLR [Node 025] [~] [Configuration] 14: 1 => 1 17:22:53.617 SERIAL » [ACK] (0x06) 17:22:53.618 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 1 17:22:53.621 SERIAL » 0x010a0013130370052325a722 (12 bytes) 17:22:53.621 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 167 └─[ConfigurationCCGet] parameter #: 35 17:22:53.621 CNTRLR « [Node 025] parameter #14 has value: 1 17:22:53.621 CNTRLR » [Node 025] querying parameter #15 value... 17:22:53.625 SERIAL « [ACK] (0x06) 17:22:53.630 SERIAL « 0x0104011301e8 (6 bytes) 17:22:53.631 SERIAL » [ACK] (0x06) 17:22:53.632 DRIVER « [RES] [SendData] was sent: true 17:22:53.646 SERIAL « 0x01070013a70000024e (9 bytes) 17:22:53.646 SERIAL » [ACK] (0x06) 17:22:53.647 DRIVER « [REQ] [SendData] callback id: 167 transmit status: OK 17:22:53.657 SERIAL « 0x010b00040013057006230101b3 (13 bytes) 17:22:53.662 CNTRLR [Node 019] [~] [Configuration] 35: 1 => 1 17:22:53.662 SERIAL » [ACK] (0x06) 17:22:53.663 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 1 17:22:53.668 SERIAL » 0x010a00131a0370051625a811 (12 bytes) 17:22:53.669 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 168 └─[ConfigurationCCGet] parameter #: 22 17:22:53.669 CNTRLR « [Node 019] parameter #35 has value: 1 17:22:53.669 CNTRLR » [Node 019] querying parameter #40 value... 17:22:53.673 SERIAL « [ACK] (0x06) 17:22:53.677 SERIAL « 0x0104011301e8 (6 bytes) 17:22:53.677 SERIAL » [ACK] (0x06) 17:22:53.678 DRIVER « [RES] [SendData] was sent: true 17:22:53.715 SERIAL « 0x01070013a800000447 (9 bytes) 17:22:53.716 SERIAL » [ACK] (0x06) 17:22:53.716 DRIVER « [REQ] [SendData] callback id: 168 transmit status: OK 17:22:53.765 SERIAL « 0x010c0004001a067006160200f079 (14 bytes) 17:22:53.770 CNTRLR [Node 026] [~] [Configuration] 22: 240 => 240 17:22:53.771 SERIAL » [ACK] (0x06) 17:22:53.772 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 240 17:22:53.775 SERIAL » 0x010900131602400225a93f (11 bytes) 17:22:53.775 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 169 └─[ThermostatModeCCGet] 17:22:53.775 CNTRLR « [Node 026] parameter #22 has value: 240 17:22:53.776 CNTRLR » [Node 026] querying parameter #29 value... 17:22:53.782 SERIAL « [ACK] (0x06) 17:22:53.785 SERIAL « 0x0104011301e8 (6 bytes) 17:22:53.785 SERIAL » [ACK] (0x06) 17:22:53.786 DRIVER « [RES] [SendData] was sent: true 17:22:53.899 SERIAL « 0x01070013a900000d4f (9 bytes) 17:22:53.899 SERIAL » [ACK] (0x06) 17:22:53.900 DRIVER « [REQ] [SendData] callback id: 169 transmit status: OK 17:22:53.983 SERIAL « 0x01090004001603400301a5 (11 bytes) 17:22:53.984 CNTRLR [Node 022] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 0] 17:22:53.984 SERIAL » [ACK] (0x06) 17:22:53.985 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ThermostatModeCCReport] mode: Heat 17:22:53.988 SERIAL » 0x010a0013170370050f25aa07 (12 bytes) 17:22:53.988 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 170 └─[ConfigurationCCGet] parameter #: 15 17:22:53.989 CNTRLR « [Node 022] received current thermostat mode: Heat 17:22:53.989 CNTRLR [Node 022] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 0] [internal] ue => true 17:22:54.015 SERIAL « [ACK] (0x06) 17:22:54.017 SERIAL « 0x0104011301e8 (6 bytes) 17:22:54.018 SERIAL » [ACK] (0x06) 17:22:54.019 DRIVER « [RES] [SendData] was sent: true 17:22:54.021 CNTRLR [Node 022] ThermostatSetpointCC: doing a partial interview... 17:22:54.021 CNTRLR » [Node 022] querying current value of setpoint Heating... 17:22:54.024 SERIAL « 0x01070013aa00000243 (9 bytes) 17:22:54.025 SERIAL » [ACK] (0x06) 17:22:54.025 DRIVER « [REQ] [SendData] callback id: 170 transmit status: OK 17:22:54.027 SERIAL « 0x010b000400170570060f01009a (13 bytes) 17:22:54.033 CNTRLR [Node 023] [~] [Configuration] 15: 0 => 0 17:22:54.033 SERIAL » [ACK] (0x06) 17:22:54.034 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 15 value size: 1 value: 0 17:22:54.037 SERIAL » 0x010a0013180370050c25ab0a (12 bytes) 17:22:54.038 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 171 └─[ConfigurationCCGet] parameter #: 12 17:22:54.038 CNTRLR « [Node 023] parameter #15 has value: 0 17:22:54.038 CNTRLR » [Node 023] querying parameter #16 value... 17:22:54.042 SERIAL « [ACK] (0x06) 17:22:54.048 SERIAL « 0x0104011301e8 (6 bytes) 17:22:54.048 SERIAL » [ACK] (0x06) 17:22:54.051 DRIVER « [RES] [SendData] was sent: true 17:22:54.066 SERIAL « 0x01070013ab00000242 (9 bytes) 17:22:54.067 SERIAL » [ACK] (0x06) 17:22:54.067 DRIVER « [REQ] [SendData] callback id: 171 transmit status: OK 17:22:54.081 SERIAL « 0x010c000400180670060c020032a3 (14 bytes) 17:22:54.093 CNTRLR [Node 024] [~] [Configuration] 12: 50 => 50 17:22:54.094 SERIAL » [ACK] (0x06) 17:22:54.095 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 50 17:22:54.099 SERIAL » 0x010a0013190370050f25ac0f (12 bytes) 17:22:54.100 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 172 └─[ConfigurationCCGet] parameter #: 15 17:22:54.100 CNTRLR « [Node 024] parameter #12 has value: 50 17:22:54.101 CNTRLR » [Node 024] querying parameter #13 value... 17:22:54.105 SERIAL « [ACK] (0x06) 17:22:54.112 SERIAL « 0x0104011301e8 (6 bytes) 17:22:54.112 SERIAL » [ACK] (0x06) 17:22:54.113 DRIVER « [RES] [SendData] was sent: true 17:22:54.125 SERIAL « 0x01070013ac00000245 (9 bytes) 17:22:54.126 SERIAL » [ACK] (0x06) 17:22:54.126 DRIVER « [REQ] [SendData] callback id: 172 transmit status: OK 17:22:54.136 SERIAL « 0x010b000400190570060f010094 (13 bytes) 17:22:54.141 CNTRLR [Node 025] [~] [Configuration] 15: 0 => 0 17:22:54.142 SERIAL » [ACK] (0x06) 17:22:54.143 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 15 value size: 1 value: 0 17:22:54.146 SERIAL » 0x010a0013130370052825ad23 (12 bytes) 17:22:54.146 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 173 └─[ConfigurationCCGet] parameter #: 40 17:22:54.147 CNTRLR « [Node 025] parameter #15 has value: 0 17:22:54.147 CNTRLR » [Node 025] querying parameter #16 value... 17:22:54.150 SERIAL « [ACK] (0x06) 17:22:54.155 SERIAL « 0x0104011301e8 (6 bytes) 17:22:54.156 SERIAL » [ACK] (0x06) 17:22:54.156 DRIVER « [RES] [SendData] was sent: true 17:22:54.171 SERIAL « 0x01070013ad00000244 (9 bytes) 17:22:54.172 SERIAL » [ACK] (0x06) 17:22:54.172 DRIVER « [REQ] [SendData] callback id: 173 transmit status: OK 17:22:54.182 SERIAL « 0x010b0004001305700628010ab3 (13 bytes) 17:22:54.188 CNTRLR [Node 019] [~] [Configuration] 40: 10 => 10 17:22:54.189 SERIAL » [ACK] (0x06) 17:22:54.189 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 10 17:22:54.195 SERIAL » 0x010a00131a0370051d25ae1c (12 bytes) 17:22:54.195 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 174 └─[ConfigurationCCGet] parameter #: 29 17:22:54.196 CNTRLR « [Node 019] parameter #40 has value: 10 17:22:54.197 CNTRLR » [Node 019] querying parameter #42 value... 17:22:54.202 SERIAL « [ACK] (0x06) 17:22:54.205 SERIAL « 0x0104011301e8 (6 bytes) 17:22:54.206 SERIAL » [ACK] (0x06) 17:22:54.207 DRIVER « [RES] [SendData] was sent: true 17:22:54.243 SERIAL « 0x01070013ae00000540 (9 bytes) 17:22:54.243 SERIAL » [ACK] (0x06) 17:22:54.244 DRIVER « [REQ] [SendData] callback id: 174 transmit status: OK 17:22:54.348 SERIAL « 0x010b0004001a0570061d010085 (13 bytes) 17:22:54.353 CNTRLR [Node 026] [~] [Configuration] 29: 0 => 0 17:22:54.354 SERIAL » [ACK] (0x06) 17:22:54.355 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 29 value size: 1 value: 0 17:22:54.358 SERIAL » 0x010a0013160343020125af39 (12 bytes) 17:22:54.358 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 175 └─[ThermostatSetpointCCGet] setpoint type: Heating 17:22:54.358 CNTRLR « [Node 026] parameter #29 has value: 0 17:22:54.359 CNTRLR » [Node 026] querying parameter #30 value... 17:22:54.367 SERIAL « [ACK] (0x06) 17:22:54.368 SERIAL « 0x0104011301e8 (6 bytes) 17:22:54.369 SERIAL » [ACK] (0x06) 17:22:54.370 DRIVER « [RES] [SendData] was sent: true 17:22:54.440 SERIAL « 0x01070013af0000084c (9 bytes) 17:22:54.441 SERIAL » [ACK] (0x06) 17:22:54.441 DRIVER « [REQ] [SendData] callback id: 175 transmit status: OK 17:22:54.530 SERIAL « 0x010c0004001606430301220064e0 (14 bytes) 17:22:54.531 CNTRLR [Node 022] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 0] 17:22:54.531 CNTRLR [Node 022] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 17:22:54.531 SERIAL » [ACK] (0x06) 17:22:54.532 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 17:22:54.535 SERIAL » 0x010a0013170370051025b002 (12 bytes) 17:22:54.536 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 176 └─[ConfigurationCCGet] parameter #: 16 17:22:54.536 CNTRLR « [Node 022] received current value of setpoint Heating: 10 °C 17:22:54.536 CNTRLR [Node 022] [~] [Thermostat Setpoint] interviewComplete [Endpoint 0] [internal] : true => true 17:22:54.562 SERIAL « [ACK] (0x06) 17:22:54.566 SERIAL « 0x0104011301e8 (6 bytes) 17:22:54.567 SERIAL » [ACK] (0x06) 17:22:54.568 DRIVER « [RES] [SendData] was sent: true 17:22:54.569 CNTRLR [Node 022] ConfigurationCC: Loading configuration parameters from device confi g 17:22:54.575 CNTRLR [Node 022] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:22:54.576 CNTRLR [Node 022] [Configuration] 1: metadata updated 17:22:54.577 CNTRLR [Node 022] [Configuration] 2: metadata updated 17:22:54.578 CNTRLR [Node 022] [Configuration] 3: metadata updated 17:22:54.579 CNTRLR [Node 022] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:22:54.579 CNTRLR » [Node 022] querying parameter #1 value... 17:22:54.582 SERIAL « 0x01070013b000000358 (9 bytes) 17:22:54.583 SERIAL » [ACK] (0x06) 17:22:54.583 DRIVER « [REQ] [SendData] callback id: 176 transmit status: OK 17:22:54.593 SERIAL « 0x010b0004001705700610010184 (13 bytes) 17:22:54.598 CNTRLR [Node 023] [~] [Configuration] 16: 1 => 1 17:22:54.599 SERIAL » [ACK] (0x06) 17:22:54.600 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 1 17:22:54.603 SERIAL » 0x010a0013180370050d25b111 (12 bytes) 17:22:54.604 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 177 └─[ConfigurationCCGet] parameter #: 13 17:22:54.604 CNTRLR « [Node 023] parameter #16 has value: 1 17:22:54.604 CNTRLR » [Node 023] querying parameter #30 value... 17:22:54.608 SERIAL « [ACK] (0x06) 17:22:54.611 SERIAL « 0x0104011301e8 (6 bytes) 17:22:54.612 SERIAL » [ACK] (0x06) 17:22:54.612 DRIVER « [RES] [SendData] was sent: true 17:22:54.632 SERIAL « 0x01070013b100000359 (9 bytes) 17:22:54.632 SERIAL » [ACK] (0x06) 17:22:54.633 DRIVER « [REQ] [SendData] callback id: 177 transmit status: OK 17:22:54.648 SERIAL « 0x010c000400180670060d02000595 (14 bytes) 17:22:54.653 CNTRLR [Node 024] [~] [Configuration] 13: 5 => 5 17:22:54.654 SERIAL » [ACK] (0x06) 17:22:54.656 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 2 value: 5 17:22:54.659 SERIAL » 0x010a0013190370051025b20e (12 bytes) 17:22:54.659 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 178 └─[ConfigurationCCGet] parameter #: 16 17:22:54.659 CNTRLR « [Node 024] parameter #13 has value: 5 17:22:54.660 CNTRLR » [Node 024] querying parameter #15 value... 17:22:54.666 SERIAL « [ACK] (0x06) 17:22:54.669 SERIAL « 0x0104011301e8 (6 bytes) 17:22:54.669 SERIAL » [ACK] (0x06) 17:22:54.673 DRIVER « [RES] [SendData] was sent: true 17:22:54.686 SERIAL « 0x01070013b20000025b (9 bytes) 17:22:54.686 SERIAL » [ACK] (0x06) 17:22:54.687 DRIVER « [REQ] [SendData] callback id: 178 transmit status: OK 17:22:54.697 SERIAL « 0x010b000400190570061001018a (13 bytes) 17:22:54.710 CNTRLR [Node 025] [~] [Configuration] 16: 1 => 1 17:22:54.711 SERIAL » [ACK] (0x06) 17:22:54.712 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 1 17:22:54.715 SERIAL » 0x010a0013130370052a25b33f (12 bytes) 17:22:54.719 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 179 └─[ConfigurationCCGet] parameter #: 42 17:22:54.720 CNTRLR « [Node 025] parameter #16 has value: 1 17:22:54.720 CNTRLR » [Node 025] querying parameter #30 value... 17:22:54.724 SERIAL « [ACK] (0x06) 17:22:54.727 SERIAL « 0x0104011301e8 (6 bytes) 17:22:54.727 SERIAL » [ACK] (0x06) 17:22:54.728 DRIVER « [RES] [SendData] was sent: true 17:22:54.744 SERIAL « 0x01070013b30000025a (9 bytes) 17:22:54.745 SERIAL » [ACK] (0x06) 17:22:54.746 DRIVER « [REQ] [SendData] callback id: 179 transmit status: OK 17:22:54.755 SERIAL « 0x010c000400130670062a020e10a2 (14 bytes) 17:22:54.760 CNTRLR [Node 019] [~] [Configuration] 42: 3600 => 3600 17:22:54.761 SERIAL » [ACK] (0x06) 17:22:54.762 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 3600 17:22:54.765 SERIAL » 0x010a00131a0370051e25b405 (12 bytes) 17:22:54.765 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 180 └─[ConfigurationCCGet] parameter #: 30 17:22:54.766 CNTRLR « [Node 019] parameter #42 has value: 3600 17:22:54.766 CNTRLR » [Node 019] querying parameter #43 value... 17:22:54.775 SERIAL « [ACK] (0x06) 17:22:54.776 SERIAL « 0x0104011301e8 (6 bytes) 17:22:54.777 SERIAL » [ACK] (0x06) 17:22:54.777 DRIVER « [RES] [SendData] was sent: true 17:22:54.812 SERIAL « 0x01070013b40000055a (9 bytes) 17:22:54.812 SERIAL » [ACK] (0x06) 17:22:54.812 DRIVER « [REQ] [SendData] callback id: 180 transmit status: OK 17:22:54.941 SERIAL « 0x010b0004001a0570061e010284 (13 bytes) 17:22:54.946 CNTRLR [Node 026] [~] [Configuration] 30: 2 => 2 17:22:54.947 SERIAL » [ACK] (0x06) 17:22:54.949 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 2 17:22:54.953 SERIAL » 0x010a0013160370050125b517 (12 bytes) 17:22:54.954 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 181 └─[ConfigurationCCGet] parameter #: 1 17:22:54.954 CNTRLR « [Node 026] parameter #30 has value: 2 17:22:54.955 CNTRLR » [Node 026] querying parameter #31 value... 17:22:54.959 SERIAL « [ACK] (0x06) 17:22:54.962 SERIAL « 0x0104011301e8 (6 bytes) 17:22:54.963 SERIAL » [ACK] (0x06) 17:22:54.964 DRIVER « [RES] [SendData] was sent: true 17:22:55.029 SERIAL « 0x01070013b500000856 (9 bytes) 17:22:55.029 SERIAL » [ACK] (0x06) 17:22:55.030 DRIVER « [REQ] [SendData] callback id: 181 transmit status: OK 17:22:55.121 SERIAL « 0x010e0004001608700601040000003ca4 (16 bytes) 17:22:55.133 CNTRLR [Node 022] [~] [Configuration] 1: 60 => 60 17:22:55.134 SERIAL » [ACK] (0x06) 17:22:55.136 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 4 value: 60 17:22:55.142 SERIAL » 0x010a0013170370051e25b60a (12 bytes) 17:22:55.143 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 182 └─[ConfigurationCCGet] parameter #: 30 17:22:55.144 CNTRLR « [Node 022] parameter #1 has value: 60 17:22:55.144 CNTRLR » [Node 022] querying parameter #2 value... 17:22:55.150 SERIAL « [ACK] (0x06) 17:22:55.153 SERIAL « 0x0104011301e8 (6 bytes) 17:22:55.154 SERIAL » [ACK] (0x06) 17:22:55.155 DRIVER « [RES] [SendData] was sent: true 17:22:55.169 SERIAL « 0x01070013b60000025f (9 bytes) 17:22:55.169 SERIAL » [ACK] (0x06) 17:22:55.170 DRIVER « [REQ] [SendData] callback id: 182 transmit status: OK 17:22:55.179 SERIAL « 0x010b000400170570061e010388 (13 bytes) 17:22:55.191 CNTRLR [Node 023] [~] [Configuration] 30: 3 => 3 17:22:55.193 SERIAL » [ACK] (0x06) 17:22:55.194 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 3 17:22:55.201 SERIAL » 0x010a0013180370050f25b715 (12 bytes) 17:22:55.201 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 183 └─[ConfigurationCCGet] parameter #: 15 17:22:55.202 CNTRLR « [Node 023] parameter #30 has value: 3 17:22:55.203 CNTRLR » [Node 023] querying parameter #31 value... 17:22:55.210 SERIAL « [ACK] (0x06) 17:22:55.212 SERIAL « 0x0104011301e8 (6 bytes) 17:22:55.212 SERIAL » [ACK] (0x06) 17:22:55.213 DRIVER « [RES] [SendData] was sent: true 17:22:55.234 SERIAL « 0x01070013b70000035f (9 bytes) 17:22:55.234 SERIAL » [ACK] (0x06) 17:22:55.235 DRIVER « [REQ] [SendData] callback id: 183 transmit status: OK 17:22:55.248 SERIAL « 0x010b000400180570060f010095 (13 bytes) 17:22:55.253 CNTRLR [Node 024] [~] [Configuration] 15: 0 => 0 17:22:55.254 SERIAL » [ACK] (0x06) 17:22:55.255 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 15 value size: 1 value: 0 17:22:55.259 SERIAL » 0x010a0013190370051e25b80a (12 bytes) 17:22:55.259 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 184 └─[ConfigurationCCGet] parameter #: 30 17:22:55.260 CNTRLR « [Node 024] parameter #15 has value: 0 17:22:55.260 CNTRLR » [Node 024] querying parameter #16 value... 17:22:55.263 SERIAL « [ACK] (0x06) 17:22:55.267 SERIAL « 0x0104011301e8 (6 bytes) 17:22:55.267 SERIAL » [ACK] (0x06) 17:22:55.268 DRIVER « [RES] [SendData] was sent: true 17:22:55.285 SERIAL « 0x01070013b800000251 (9 bytes) 17:22:55.285 SERIAL » [ACK] (0x06) 17:22:55.286 DRIVER « [REQ] [SendData] callback id: 184 transmit status: OK 17:22:55.295 SERIAL « 0x010b000400190570061e010386 (13 bytes) 17:22:55.300 CNTRLR [Node 025] [~] [Configuration] 30: 3 => 3 17:22:55.301 SERIAL » [ACK] (0x06) 17:22:55.302 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 3 17:22:55.306 SERIAL » 0x010a0013130370052b25b934 (12 bytes) 17:22:55.306 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 185 └─[ConfigurationCCGet] parameter #: 43 17:22:55.307 CNTRLR « [Node 025] parameter #30 has value: 3 17:22:55.308 CNTRLR » [Node 025] querying parameter #31 value... 17:22:55.311 SERIAL « [ACK] (0x06) 17:22:55.315 SERIAL « 0x0104011301e8 (6 bytes) 17:22:55.315 SERIAL » [ACK] (0x06) 17:22:55.316 DRIVER « [RES] [SendData] was sent: true 17:22:55.332 SERIAL « 0x01070013b900000250 (9 bytes) 17:22:55.332 SERIAL » [ACK] (0x06) 17:22:55.333 DRIVER « [REQ] [SendData] callback id: 185 transmit status: OK 17:22:55.342 SERIAL « 0x010b000400130570062b010ab0 (13 bytes) 17:22:55.348 CNTRLR [Node 019] [~] [Configuration] 43: 10 => 10 17:22:55.348 SERIAL » [ACK] (0x06) 17:22:55.349 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 10 17:22:55.353 SERIAL » 0x010a00131a0370051f25ba0a (12 bytes) 17:22:55.353 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 186 └─[ConfigurationCCGet] parameter #: 31 17:22:55.353 CNTRLR « [Node 019] parameter #43 has value: 10 17:22:55.354 CNTRLR » [Node 019] querying parameter #44 value... 17:22:55.357 SERIAL « [ACK] (0x06) 17:22:55.361 SERIAL « 0x0104011301e8 (6 bytes) 17:22:55.362 SERIAL » [ACK] (0x06) 17:22:55.362 DRIVER « [RES] [SendData] was sent: true 17:22:55.399 SERIAL « 0x01070013ba00000554 (9 bytes) 17:22:55.400 SERIAL » [ACK] (0x06) 17:22:55.400 DRIVER « [REQ] [SendData] callback id: 186 transmit status: OK 17:22:55.448 SERIAL « 0x010b0004001a0570061f010087 (13 bytes) 17:22:55.453 CNTRLR [Node 026] [~] [Configuration] 31: 0 => 0 17:22:55.454 SERIAL » [ACK] (0x06) 17:22:55.455 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 0 17:22:55.459 SERIAL » 0x010a0013160370050225bb1a (12 bytes) 17:22:55.459 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 187 └─[ConfigurationCCGet] parameter #: 2 17:22:55.460 CNTRLR « [Node 026] parameter #31 has value: 0 17:22:55.461 CNTRLR » [Node 026] querying parameter #32 value... 17:22:55.465 SERIAL « [ACK] (0x06) 17:22:55.468 SERIAL « 0x0104011301e8 (6 bytes) 17:22:55.469 SERIAL » [ACK] (0x06) 17:22:55.469 DRIVER « [RES] [SendData] was sent: true 17:22:55.541 SERIAL « 0x01070013bb00000858 (9 bytes) 17:22:55.542 SERIAL » [ACK] (0x06) 17:22:55.542 DRIVER « [REQ] [SendData] callback id: 187 transmit status: OK 17:22:55.635 SERIAL « 0x010e000400160870060204000000019a (16 bytes) 17:22:55.640 CNTRLR [Node 022] [~] [Configuration] 2: 1 => 1 17:22:55.641 SERIAL » [ACK] (0x06) 17:22:55.642 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 4 value: 1 17:22:55.646 SERIAL » 0x010a0013170370051f25bc01 (12 bytes) 17:22:55.646 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 188 └─[ConfigurationCCGet] parameter #: 31 17:22:55.647 CNTRLR « [Node 022] parameter #2 has value: 1 17:22:55.647 CNTRLR » [Node 022] querying parameter #3 value... 17:22:55.651 SERIAL « [ACK] (0x06) 17:22:55.655 SERIAL « 0x0104011301e8 (6 bytes) 17:22:55.655 SERIAL » [ACK] (0x06) 17:22:55.656 DRIVER « [RES] [SendData] was sent: true 17:22:55.672 SERIAL « 0x01070013bc00000255 (9 bytes) 17:22:55.672 SERIAL » [ACK] (0x06) 17:22:55.673 DRIVER « [REQ] [SendData] callback id: 188 transmit status: OK 17:22:55.695 SERIAL « 0x010b000400170570061f010288 (13 bytes) 17:22:55.701 CNTRLR [Node 023] [~] [Configuration] 31: 2 => 2 17:22:55.702 SERIAL » [ACK] (0x06) 17:22:55.703 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 2 17:22:55.706 SERIAL » 0x010a0013180370051025bd00 (12 bytes) 17:22:55.707 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 189 └─[ConfigurationCCGet] parameter #: 16 17:22:55.707 CNTRLR « [Node 023] parameter #31 has value: 2 17:22:55.707 CNTRLR » [Node 023] querying parameter #32 value... 17:22:55.713 SERIAL « [ACK] (0x06) 17:22:55.726 SERIAL « 0x0104011301e8 (6 bytes) 17:22:55.726 SERIAL » [ACK] (0x06) 17:22:55.727 DRIVER « [RES] [SendData] was sent: true 17:22:55.737 SERIAL « 0x01070013bd00000254 (9 bytes) 17:22:55.738 SERIAL » [ACK] (0x06) 17:22:55.739 DRIVER « [REQ] [SendData] callback id: 189 transmit status: OK 17:22:55.751 SERIAL « 0x010b000400180570061001008a (13 bytes) 17:22:55.757 CNTRLR [Node 024] [~] [Configuration] 16: 0 => 0 17:22:55.758 SERIAL » [ACK] (0x06) 17:22:55.759 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 0 17:22:55.762 SERIAL » 0x010a0013190370051f25be0d (12 bytes) 17:22:55.763 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 190 └─[ConfigurationCCGet] parameter #: 31 17:22:55.763 CNTRLR « [Node 024] parameter #16 has value: 0 17:22:55.764 CNTRLR » [Node 024] querying parameter #17 value... 17:22:55.772 SERIAL « [ACK] (0x06) 17:22:55.773 SERIAL « 0x0104011301e8 (6 bytes) 17:22:55.774 SERIAL » [ACK] (0x06) 17:22:55.774 DRIVER « [RES] [SendData] was sent: true 17:22:55.789 SERIAL « 0x01070013be00000356 (9 bytes) 17:22:55.789 SERIAL » [ACK] (0x06) 17:22:55.789 DRIVER « [REQ] [SendData] callback id: 190 transmit status: OK 17:22:55.799 SERIAL « 0x010b000400190570061f010286 (13 bytes) 17:22:55.804 CNTRLR [Node 025] [~] [Configuration] 31: 2 => 2 17:22:55.805 SERIAL » [ACK] (0x06) 17:22:55.806 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 2 17:22:55.815 SERIAL » 0x010a0013130370052c25bf35 (12 bytes) 17:22:55.817 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 191 └─[ConfigurationCCGet] parameter #: 44 17:22:55.817 CNTRLR « [Node 025] parameter #31 has value: 2 17:22:55.817 CNTRLR » [Node 025] querying parameter #32 value... 17:22:55.822 SERIAL « [ACK] (0x06) 17:22:55.825 SERIAL « 0x0104011301e8 (6 bytes) 17:22:55.825 SERIAL » [ACK] (0x06) 17:22:55.826 DRIVER « [RES] [SendData] was sent: true 17:22:55.843 SERIAL « 0x01070013bf00000256 (9 bytes) 17:22:55.844 SERIAL » [ACK] (0x06) 17:22:55.844 DRIVER « [REQ] [SendData] callback id: 191 transmit status: OK 17:22:55.852 SERIAL « 0x010b000400130570062c0100bd (13 bytes) 17:22:55.858 CNTRLR [Node 019] [~] [Configuration] 44: 0 => 0 17:22:55.858 SERIAL » [ACK] (0x06) 17:22:55.859 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 44 value size: 1 value: 0 17:22:55.867 SERIAL » 0x010a00131a0370052025c04f (12 bytes) 17:22:55.867 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 192 └─[ConfigurationCCGet] parameter #: 32 17:22:55.868 CNTRLR « [Node 019] parameter #44 has value: 0 17:22:55.868 CNTRLR » [Node 019] querying parameter #50 value... 17:22:55.871 SERIAL « [ACK] (0x06) 17:22:55.875 SERIAL « 0x0104011301e8 (6 bytes) 17:22:55.876 SERIAL » [ACK] (0x06) 17:22:55.876 DRIVER « [RES] [SendData] was sent: true 17:22:55.914 SERIAL « 0x01070013c00000042f (9 bytes) 17:22:55.914 SERIAL » [ACK] (0x06) 17:22:55.915 DRIVER « [REQ] [SendData] callback id: 192 transmit status: OK 17:22:55.962 SERIAL « 0x010b0004001a057006200101b9 (13 bytes) 17:22:55.967 CNTRLR [Node 026] [~] [Configuration] 32: 1 => 1 17:22:55.968 SERIAL » [ACK] (0x06) 17:22:55.969 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 1 value: 1 17:22:55.972 SERIAL » 0x010a0013160370050325c161 (12 bytes) 17:22:55.972 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 193 └─[ConfigurationCCGet] parameter #: 3 17:22:55.973 CNTRLR « [Node 026] parameter #32 has value: 1 17:22:55.973 CNTRLR » [Node 026] querying parameter #33 value... 17:22:55.976 SERIAL « [ACK] (0x06) 17:22:55.980 SERIAL « 0x0104011301e8 (6 bytes) 17:22:55.981 SERIAL » [ACK] (0x06) 17:22:55.982 DRIVER « [RES] [SendData] was sent: true 17:22:56.039 SERIAL « 0x01070013c10000072d (9 bytes) 17:22:56.039 SERIAL » [ACK] (0x06) 17:22:56.040 DRIVER « [REQ] [SendData] callback id: 193 transmit status: OK 17:22:56.132 SERIAL « 0x010e000400160870060304000000019b (16 bytes) 17:22:56.137 CNTRLR [Node 022] [~] [Configuration] 3: 1 => 1 17:22:56.138 SERIAL » [ACK] (0x06) 17:22:56.139 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 4 value: 1 17:22:56.142 SERIAL » 0x010a0013170370052025c240 (12 bytes) 17:22:56.142 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 194 └─[ConfigurationCCGet] parameter #: 32 17:22:56.143 CNTRLR « [Node 022] parameter #3 has value: 1 17:22:56.143 CNTRLR [Node 022] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:22:56.171 SERIAL « [ACK] (0x06) 17:22:56.175 SERIAL « 0x0104011301e8 (6 bytes) 17:22:56.176 SERIAL » [ACK] (0x06) 17:22:56.178 DRIVER « [RES] [SendData] was sent: true 17:22:56.180 CNTRLR [Node 022] ProtectionCC: doing a partial interview... 17:22:56.181 CNTRLR » [Node 022] querying protection status... 17:22:56.183 SERIAL « 0x01070013c20000022b (9 bytes) 17:22:56.183 SERIAL » [ACK] (0x06) 17:22:56.185 DRIVER « [REQ] [SendData] callback id: 194 transmit status: OK 17:22:56.187 SERIAL « 0x010b00040017057006200103b6 (13 bytes) 17:22:56.192 CNTRLR [Node 023] [~] [Configuration] 32: 3 => 3 17:22:56.193 SERIAL » [ACK] (0x06) 17:22:56.194 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 1 value: 3 17:22:56.201 SERIAL » 0x010a0013180370051125c37f (12 bytes) 17:22:56.201 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 195 └─[ConfigurationCCGet] parameter #: 17 17:22:56.202 CNTRLR « [Node 023] parameter #32 has value: 3 17:22:56.202 CNTRLR » [Node 023] querying parameter #33 value... 17:22:56.207 SERIAL « [ACK] (0x06) 17:22:56.209 SERIAL « 0x0104011301e8 (6 bytes) 17:22:56.210 SERIAL » [ACK] (0x06) 17:22:56.211 DRIVER « [RES] [SendData] was sent: true 17:22:56.230 SERIAL « 0x01070013c30000032b (9 bytes) 17:22:56.230 SERIAL » [ACK] (0x06) 17:22:56.231 DRIVER « [REQ] [SendData] callback id: 195 transmit status: OK 17:22:56.244 SERIAL « 0x010c0004001806700611020032be (14 bytes) 17:22:56.250 CNTRLR [Node 024] [~] [Configuration] 17: 50 => 50 17:22:56.250 SERIAL » [ACK] (0x06) 17:22:56.251 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 17 value size: 2 value: 50 17:22:56.254 SERIAL » 0x010a0013190370052025c448 (12 bytes) 17:22:56.255 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 196 └─[ConfigurationCCGet] parameter #: 32 17:22:56.255 CNTRLR « [Node 024] parameter #17 has value: 50 17:22:56.255 CNTRLR » [Node 024] querying parameter #18 value... 17:22:56.258 SERIAL « [ACK] (0x06) 17:22:56.263 SERIAL « 0x0104011301e8 (6 bytes) 17:22:56.263 SERIAL » [ACK] (0x06) 17:22:56.264 DRIVER « [RES] [SendData] was sent: true 17:22:56.280 SERIAL « 0x01070013c40000032c (9 bytes) 17:22:56.280 SERIAL » [ACK] (0x06) 17:22:56.281 DRIVER « [REQ] [SendData] callback id: 196 transmit status: OK 17:22:56.290 SERIAL « 0x010b00040019057006200103b8 (13 bytes) 17:22:56.295 CNTRLR [Node 025] [~] [Configuration] 32: 3 => 3 17:22:56.296 SERIAL » [ACK] (0x06) 17:22:56.300 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 1 value: 3 17:22:56.303 SERIAL » 0x010a0013130370053225c551 (12 bytes) 17:22:56.303 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 197 └─[ConfigurationCCGet] parameter #: 50 17:22:56.304 CNTRLR « [Node 025] parameter #32 has value: 3 17:22:56.304 CNTRLR » [Node 025] querying parameter #33 value... 17:22:56.307 SERIAL « [ACK] (0x06) 17:22:56.312 SERIAL « 0x0104011301e8 (6 bytes) 17:22:56.313 SERIAL » [ACK] (0x06) 17:22:56.313 DRIVER « [RES] [SendData] was sent: true 17:22:56.328 SERIAL « 0x01070013c50000032d (9 bytes) 17:22:56.329 SERIAL » [ACK] (0x06) 17:22:56.329 DRIVER « [REQ] [SendData] callback id: 197 transmit status: OK 17:22:56.339 SERIAL « 0x010b00040013057006320100a3 (13 bytes) 17:22:56.344 CNTRLR [Node 019] [~] [Configuration] 50: 0 => 0 17:22:56.345 SERIAL » [ACK] (0x06) 17:22:56.346 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 0 17:22:56.349 SERIAL » 0x010a00131a0370052125c648 (12 bytes) 17:22:56.349 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 198 └─[ConfigurationCCGet] parameter #: 33 17:22:56.349 CNTRLR « [Node 019] parameter #50 has value: 0 17:22:56.350 CNTRLR [Node 019] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:22:56.352 SERIAL « [ACK] (0x06) 17:22:56.388 SERIAL « 0x0104011301e8 (6 bytes) 17:22:56.388 SERIAL » [ACK] (0x06) 17:22:56.389 DRIVER « [RES] [SendData] was sent: true 17:22:56.396 SERIAL « 0x01070013c600000429 (9 bytes) 17:22:56.396 SERIAL » [ACK] (0x06) 17:22:56.397 DRIVER « [REQ] [SendData] callback id: 198 transmit status: OK 17:22:56.432 CNTRLR [Node 019] ProtectionCC: doing a partial interview... 17:22:56.432 CNTRLR » [Node 019] querying protection status... 17:22:56.444 SERIAL « 0x010b0004001a057006210101b8 (13 bytes) 17:22:56.449 CNTRLR [Node 026] [~] [Configuration] 33: 1 => 1 17:22:56.451 SERIAL » [ACK] (0x06) 17:22:56.451 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 1 value: 1 17:22:56.454 SERIAL » 0x010900131602750225c764 (11 bytes) 17:22:56.455 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 199 └─[ProtectionCCGet] 17:22:56.455 CNTRLR « [Node 026] parameter #33 has value: 1 17:22:56.455 CNTRLR » [Node 026] querying parameter #35 value... 17:22:56.463 SERIAL « [ACK] (0x06) 17:22:56.466 SERIAL « 0x0104011301e8 (6 bytes) 17:22:56.466 SERIAL » [ACK] (0x06) 17:22:56.468 DRIVER « [RES] [SendData] was sent: true 17:22:56.538 SERIAL « 0x01070013c700000824 (9 bytes) 17:22:56.539 SERIAL » [ACK] (0x06) 17:22:56.539 DRIVER « [REQ] [SendData] callback id: 199 transmit status: OK 17:22:56.623 SERIAL « 0x0109000400160375030091 (11 bytes) 17:22:56.624 CNTRLR [Node 022] [~] [Protection] local: 0 => 0 [Endpoint 0] 17:22:56.624 SERIAL » [ACK] (0x06) 17:22:56.626 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected 17:22:56.631 SERIAL » 0x010a0013170370052125c84b (12 bytes) 17:22:56.632 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 200 └─[ConfigurationCCGet] parameter #: 33 17:22:56.633 CNTRLR « [Node 022] received protection status: local: Unprotected 17:22:56.633 CNTRLR [Node 022] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 17:22:56.690 SERIAL « [ACK] (0x06) 17:22:56.695 SERIAL « 0x0104011301e8 (6 bytes) 17:22:56.696 SERIAL » [ACK] (0x06) 17:22:56.699 DRIVER « [RES] [SendData] was sent: true 17:22:56.702 CNTRLR [Node 022] ClockCC: doing a partial interview... 17:22:56.703 CNTRLR » [Node 022] requesting current clock setting... 17:22:56.707 SERIAL « 0x01070013c800000221 (9 bytes) 17:22:56.707 SERIAL » [ACK] (0x06) 17:22:56.708 DRIVER « [REQ] [SendData] callback id: 200 transmit status: OK 17:22:56.712 SERIAL « 0x010b00040017057006210101b5 (13 bytes) 17:22:56.721 CNTRLR [Node 023] [~] [Configuration] 33: 1 => 1 17:22:56.723 SERIAL » [ACK] (0x06) 17:22:56.724 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 1 value: 1 17:22:56.728 SERIAL » 0x010a0013180370051225c976 (12 bytes) 17:22:56.728 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 201 └─[ConfigurationCCGet] parameter #: 18 17:22:56.728 CNTRLR « [Node 023] parameter #33 has value: 1 17:22:56.728 CNTRLR » [Node 023] querying parameter #39 value... 17:22:56.732 SERIAL « [ACK] (0x06) 17:22:56.738 SERIAL « 0x0104011301e8 (6 bytes) 17:22:56.738 SERIAL » [ACK] (0x06) 17:22:56.739 DRIVER « [RES] [SendData] was sent: true 17:22:56.757 SERIAL « 0x01070013c900000220 (9 bytes) 17:22:56.757 SERIAL » [ACK] (0x06) 17:22:56.758 DRIVER « [REQ] [SendData] callback id: 201 transmit status: OK 17:22:56.771 SERIAL « 0x010c00040018067006120200058a (14 bytes) 17:22:56.777 CNTRLR [Node 024] [~] [Configuration] 18: 5 => 5 17:22:56.777 SERIAL » [ACK] (0x06) 17:22:56.778 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 18 value size: 2 value: 5 17:22:56.781 SERIAL » 0x010a0013190370052125ca47 (12 bytes) 17:22:56.782 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 202 └─[ConfigurationCCGet] parameter #: 33 17:22:56.782 CNTRLR « [Node 024] parameter #18 has value: 5 17:22:56.782 CNTRLR » [Node 024] querying parameter #20 value... 17:22:56.787 SERIAL « [ACK] (0x06) 17:22:56.792 SERIAL « 0x0104011301e8 (6 bytes) 17:22:56.793 SERIAL » [ACK] (0x06) 17:22:56.794 DRIVER « [RES] [SendData] was sent: true 17:22:56.808 SERIAL « 0x01070013ca00000223 (9 bytes) 17:22:56.808 SERIAL » [ACK] (0x06) 17:22:56.809 DRIVER « [REQ] [SendData] callback id: 202 transmit status: OK 17:22:56.819 SERIAL « 0x010b00040019057006210101bb (13 bytes) 17:22:56.824 CNTRLR [Node 025] [~] [Configuration] 33: 1 => 1 17:22:56.824 SERIAL » [ACK] (0x06) 17:22:56.825 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 1 value: 1 17:22:56.828 SERIAL » 0x010900131302750225cb6d (11 bytes) 17:22:56.829 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 203 └─[ProtectionCCGet] 17:22:56.829 CNTRLR « [Node 025] parameter #33 has value: 1 17:22:56.829 CNTRLR » [Node 025] querying parameter #39 value... 17:22:56.832 SERIAL « [ACK] (0x06) 17:22:56.837 SERIAL « 0x0104011301e8 (6 bytes) 17:22:56.838 SERIAL » [ACK] (0x06) 17:22:56.838 DRIVER « [RES] [SendData] was sent: true 17:22:56.853 SERIAL « 0x01070013cb00000222 (9 bytes) 17:22:56.854 SERIAL » [ACK] (0x06) 17:22:56.854 DRIVER « [REQ] [SendData] callback id: 203 transmit status: OK 17:22:56.864 SERIAL « 0x010a00040013047503000090 (12 bytes) 17:22:56.865 CNTRLR [Node 019] [~] [Protection] local: 0 => 0 [Endpoint 0] 17:22:56.865 CNTRLR [Node 019] [~] [Protection] rf: 0 => 0 [Endpoint 0] 17:22:56.865 SERIAL » [ACK] (0x06) 17:22:56.867 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 17:22:56.869 SERIAL » 0x010a00131a0370052325cc40 (12 bytes) 17:22:56.870 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 204 └─[ConfigurationCCGet] parameter #: 35 17:22:56.870 CNTRLR « [Node 019] received protection status: local: Unprotected rf Unprotected 17:22:56.871 CNTRLR [Node 019] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 17:22:56.902 SERIAL « [ACK] (0x06) 17:22:56.905 SERIAL « 0x0104011301e8 (6 bytes) 17:22:56.906 SERIAL » [ACK] (0x06) 17:22:56.907 DRIVER « [RES] [SendData] was sent: true 17:22:56.910 CNTRLR [Node 019] FibaroVenetianBlindCC: doing a partial interview... 17:22:56.910 CNTRLR » [Node 019] Requesting venetian blind position and tilt... 17:22:56.916 SERIAL « 0x01070013cc00000423 (9 bytes) 17:22:56.917 SERIAL » [ACK] (0x06) 17:22:56.917 DRIVER « [REQ] [SendData] callback id: 204 transmit status: OK 17:22:56.964 SERIAL « 0x010b0004001a057006230101ba (13 bytes) 17:22:56.969 CNTRLR [Node 026] [~] [Configuration] 35: 1 => 1 17:22:56.970 SERIAL » [ACK] (0x06) 17:22:56.971 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 1 17:22:56.974 SERIAL » 0x010c0013130591010f260225cda5 (14 bytes) 17:22:56.974 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 205 └─[FibaroVenetianBlindCCGet] payload: 0x0f2602 17:22:56.975 CNTRLR « [Node 026] parameter #35 has value: 1 17:22:56.975 CNTRLR » [Node 026] querying parameter #40 value... 17:22:56.978 SERIAL « [ACK] (0x06) 17:22:56.984 SERIAL « 0x0104011301e8 (6 bytes) 17:22:56.984 SERIAL » [ACK] (0x06) 17:22:56.985 DRIVER « [RES] [SendData] was sent: true 17:22:57.046 SERIAL « 0x01070013cd00000620 (9 bytes) 17:22:57.046 SERIAL » [ACK] (0x06) 17:22:57.046 DRIVER « [REQ] [SendData] callback id: 205 transmit status: OK 17:22:57.057 SERIAL « 0x010e000400130891010f260302630035 (16 bytes) 17:22:57.059 CNTRLR [Node 019] [Manufacturer Proprietary] fibaro[venetianBlindsPositi [Endpoint 0] on]: metadata updated 17:22:57.059 CNTRLR [Node 019] [~] [Manufacturer Proprietary] fibaro[venetianBlindsPo [Endpoint 0] sition]: 1 => 99 17:22:57.060 SERIAL » [ACK] (0x06) 17:22:57.061 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[FibaroVenetianBlindCCReport] position: 99 17:22:57.064 SERIAL » 0x010900131602810525ce9e (11 bytes) 17:22:57.064 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 206 └─[ClockCCGet] 17:22:57.064 CNTRLR « [Node 019] received venetian blind state: position: 99 tilt: undefined 17:22:57.065 CNTRLR [Node 019] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 17:22:57.065 CNTRLR [Node 019] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 17:22:57.092 SERIAL « [ACK] (0x06) 17:22:57.095 SERIAL « 0x0104011301e8 (6 bytes) 17:22:57.095 SERIAL » [ACK] (0x06) 17:22:57.096 DRIVER « [RES] [SendData] was sent: true 17:22:57.099 CNTRLR [Node 019] Interview stage completed: CommandClasses 17:22:57.099 CNTRLR [Node 019] Interview stage completed: OverwriteConfig 17:22:57.099 CNTRLR » [Node 019] requesting node neighbors... 17:22:57.104 SERIAL « 0x01070013ce00000326 (9 bytes) 17:22:57.104 SERIAL » [ACK] (0x06) 17:22:57.105 DRIVER « [REQ] [SendData] callback id: 206 transmit status: OK 17:22:57.178 SERIAL « 0x010a00040016048106720d1b (12 bytes) 17:22:57.179 SERIAL » [ACK] (0x06) 17:22:57.180 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[ClockCCReport] clock setting: Wednesday, 18:13 17:22:57.183 SERIAL » 0x01070080130000006b (9 bytes) 17:22:57.183 DRIVER » [Node 019] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:22:57.184 CNTRLR « [Node 022] received current clock setting: Wednesday, 18:13 17:22:57.184 CNTRLR [Node 022] [~] [Clock] interviewComplete: true => true [Endpoint 0] [internal] 17:22:57.184 CNTRLR [Node 022] AssociationCC: doing a partial interview... 17:22:57.185 CNTRLR [Node 022] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:22:57.185 CNTRLR [Node 022] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:22:57.185 CNTRLR [Node 022] MultiChannelAssociationCC: doing a partial interview... 17:22:57.185 CNTRLR » [Node 022] querying multi channel association group #1... 17:22:57.189 SERIAL « [ACK] (0x06) 17:22:57.190 SERIAL « 0x0120018065fafa670700000000000000000000000000000000000000000000000 (34 bytes) 05b 17:22:57.190 SERIAL » [ACK] (0x06) 17:22:57.191 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 10, 12, 13, 14, 15, 16, 18, 20, 21, 22, 23, 24, 25, 26 , 27, 30, 31, 33, 34, 35 17:22:57.195 SERIAL » 0x010a001316038e020125cf94 (12 bytes) 17:22:57.196 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 207 └─[MultiChannelAssociationCCGet] group id: 1 17:22:57.196 CNTRLR « [Node 019] node neighbors received: 1, 3, 6, 7, 10, 12, 13, 14, 15, 16, 18, 20, 21, 22, 23, 24, 25, 26, 27, 30, 31, 33, 34, 35 17:22:57.197 CNTRLR [Node 019] Interview stage completed: Neighbors 17:22:57.197 CNTRLR [Node 019] Interview completed 17:22:57.200 SERIAL « [ACK] (0x06) 17:22:57.204 SERIAL « 0x0104011301e8 (6 bytes) 17:22:57.204 SERIAL » [ACK] (0x06) 17:22:57.205 DRIVER « [RES] [SendData] was sent: true 17:22:57.225 SERIAL « 0x01070013cf00000226 (9 bytes) 17:22:57.225 SERIAL » [ACK] (0x06) 17:22:57.225 DRIVER « [REQ] [SendData] callback id: 207 transmit status: OK 17:22:57.245 SERIAL « 0x010e00040016088e0301010000010067 (16 bytes) 17:22:57.246 SERIAL » [ACK] (0x06) 17:22:57.247 CNTRLR [Node 022] [~] [Multi Channel Association] maxNodes[1]: 1 => 1 17:22:57.248 CNTRLR [Node 022] [~] [Multi Channel Association] nodeIds[1]: => 17:22:57.249 CNTRLR [Node 022] [~] [Multi Channel Association] endpoints[1]: [object Object] => [o bject Object] 17:22:57.250 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 1 node ids: endpoints: 1:0 17:22:57.253 SERIAL » 0x010a0013170370052725d055 (12 bytes) 17:22:57.253 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 208 └─[ConfigurationCCGet] parameter #: 39 17:22:57.254 CNTRLR « [Node 022] received information for multi channel association group #1: maximum # of nodes: 1 currently assigned nodes: currently assigned endpoints: 1:0 17:22:57.254 CNTRLR [Node 022] [~] [Association] hasLifeline: true => true [internal] 17:22:57.255 CNTRLR [Node 022] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:22:57.282 SERIAL « [ACK] (0x06) 17:22:57.286 SERIAL « 0x0104011301e8 (6 bytes) 17:22:57.286 SERIAL » [ACK] (0x06) 17:22:57.290 DRIVER « [RES] [SendData] was sent: true 17:22:57.296 CNTRLR [Node 022] AssociationGroupInfoCC: doing a partial interview... 17:22:57.297 CNTRLR [Node 022] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 17:22:57.297 CNTRLR [Node 022] NotificationCC: doing a partial interview... 17:22:57.298 CNTRLR [Node 022] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 17:22:57.298 CNTRLR [Node 022] Interview stage completed: CommandClasses 17:22:57.298 CNTRLR [Node 022] Interview stage completed: OverwriteConfig 17:22:57.298 CNTRLR » [Node 022] requesting node neighbors... 17:22:57.301 SERIAL « 0x01070013d000000338 (9 bytes) 17:22:57.301 SERIAL » [ACK] (0x06) 17:22:57.305 DRIVER « [REQ] [SendData] callback id: 208 transmit status: OK 17:22:57.309 SERIAL « 0x010c0004001706700627020258ef (14 bytes) 17:22:57.314 CNTRLR [Node 023] [~] [Configuration] 39: 600 => 600 17:22:57.315 SERIAL » [ACK] (0x06) 17:22:57.316 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 39 value size: 2 value: 600 17:22:57.319 SERIAL » 0x01070080160000006e (9 bytes) 17:22:57.319 DRIVER » [Node 022] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:22:57.319 CNTRLR « [Node 023] parameter #39 has value: 600 17:22:57.320 CNTRLR » [Node 023] querying parameter #40 value... 17:22:57.323 SERIAL « [ACK] (0x06) 17:22:57.324 SERIAL « 0x0120018065f8ce530700000000000000000000000000000000000000000000000 (34 bytes) 059 17:22:57.325 SERIAL » [ACK] (0x06) 17:22:57.325 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 12, 13, 14, 15, 16, 18, 19, 20, 23, 24, 25, 26, 29, 31 , 33, 34, 35 17:22:57.334 SERIAL » 0x010a0013180370051425d168 (12 bytes) 17:22:57.335 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 209 └─[ConfigurationCCGet] parameter #: 20 17:22:57.335 CNTRLR « [Node 022] node neighbors received: 1, 3, 6, 7, 12, 13, 14, 15, 16, 18, 19, 20, 23, 24, 25, 26, 29, 31, 33, 34, 35 17:22:57.335 CNTRLR [Node 022] Interview stage completed: Neighbors 17:22:57.335 CNTRLR [Node 022] Interview completed 17:22:57.337 SERIAL « [ACK] (0x06) 17:22:57.342 SERIAL « 0x0104011301e8 (6 bytes) 17:22:57.343 SERIAL » [ACK] (0x06) 17:22:57.343 DRIVER « [RES] [SendData] was sent: true 17:22:57.363 SERIAL « 0x01070013d100000339 (9 bytes) 17:22:57.364 SERIAL » [ACK] (0x06) 17:22:57.364 DRIVER « [REQ] [SendData] callback id: 209 transmit status: OK 17:22:57.378 SERIAL « 0x010b000400180570061401028c (13 bytes) 17:22:57.383 CNTRLR [Node 024] [~] [Configuration] 20: 2 => 2 17:22:57.384 SERIAL » [ACK] (0x06) 17:22:57.386 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 2 17:22:57.389 SERIAL » 0x010a0013190370052725d259 (12 bytes) 17:22:57.389 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 210 └─[ConfigurationCCGet] parameter #: 39 17:22:57.389 CNTRLR « [Node 024] parameter #20 has value: 2 17:22:57.390 CNTRLR » [Node 024] querying parameter #21 value... 17:22:57.394 SERIAL « [ACK] (0x06) 17:22:57.397 SERIAL « 0x0104011301e8 (6 bytes) 17:22:57.398 SERIAL » [ACK] (0x06) 17:22:57.398 DRIVER « [RES] [SendData] was sent: true 17:22:57.415 SERIAL « 0x01070013d20000023b (9 bytes) 17:22:57.415 SERIAL » [ACK] (0x06) 17:22:57.415 DRIVER « [REQ] [SendData] callback id: 210 transmit status: OK 17:22:57.425 SERIAL « 0x010c0004001906700627020258e1 (14 bytes) 17:22:57.430 CNTRLR [Node 025] [~] [Configuration] 39: 600 => 600 17:22:57.431 SERIAL » [ACK] (0x06) 17:22:57.432 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 39 value size: 2 value: 600 17:22:57.435 SERIAL » 0x010a00131a0370052825d354 (12 bytes) 17:22:57.435 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 211 └─[ConfigurationCCGet] parameter #: 40 17:22:57.436 CNTRLR « [Node 025] parameter #39 has value: 600 17:22:57.436 CNTRLR » [Node 025] querying parameter #40 value... 17:22:57.439 SERIAL « [ACK] (0x06) 17:22:57.444 SERIAL « 0x0104011301e8 (6 bytes) 17:22:57.445 SERIAL » [ACK] (0x06) 17:22:57.446 DRIVER « [RES] [SendData] was sent: true 17:22:57.482 SERIAL « 0x01070013d30000053d (9 bytes) 17:22:57.482 SERIAL » [ACK] (0x06) 17:22:57.483 DRIVER « [REQ] [SendData] callback id: 211 transmit status: OK 17:22:57.530 SERIAL « 0x010b0004001a05700628010aba (13 bytes) 17:22:57.535 CNTRLR [Node 026] [~] [Configuration] 40: 10 => 10 17:22:57.536 SERIAL » [ACK] (0x06) 17:22:57.537 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 10 17:22:57.540 SERIAL » 0x010a0013170370052825d45e (12 bytes) 17:22:57.540 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 212 └─[ConfigurationCCGet] parameter #: 40 17:22:57.541 CNTRLR « [Node 026] parameter #40 has value: 10 17:22:57.541 CNTRLR » [Node 026] querying parameter #42 value... 17:22:57.544 SERIAL « [ACK] (0x06) 17:22:57.548 SERIAL « 0x0104011301e8 (6 bytes) 17:22:57.549 SERIAL » [ACK] (0x06) 17:22:57.549 DRIVER « [RES] [SendData] was sent: true 17:22:57.625 SERIAL « 0x01070013d400000837 (9 bytes) 17:22:57.626 SERIAL » [ACK] (0x06) 17:22:57.626 DRIVER « [REQ] [SendData] callback id: 212 transmit status: OK 17:22:57.636 SERIAL « 0x010b00040017057006280103be (13 bytes) 17:22:57.641 CNTRLR [Node 023] [~] [Configuration] 40: 3 => 3 17:22:57.642 SERIAL » [ACK] (0x06) 17:22:57.643 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 3 17:22:57.646 SERIAL » 0x010a0013180370051525d56d (12 bytes) 17:22:57.646 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 213 └─[ConfigurationCCGet] parameter #: 21 17:22:57.647 CNTRLR « [Node 023] parameter #40 has value: 3 17:22:57.647 CNTRLR » [Node 023] querying parameter #41 value... 17:22:57.650 SERIAL « [ACK] (0x06) 17:22:57.654 SERIAL « 0x0104011301e8 (6 bytes) 17:22:57.655 SERIAL » [ACK] (0x06) 17:22:57.656 DRIVER « [RES] [SendData] was sent: true 17:22:57.675 SERIAL « 0x01070013d50000023c (9 bytes) 17:22:57.675 SERIAL » [ACK] (0x06) 17:22:57.676 DRIVER « [REQ] [SendData] callback id: 213 transmit status: OK 17:22:57.689 SERIAL « 0x010b000400180570061501008f (13 bytes) 17:22:57.694 CNTRLR [Node 024] [~] [Configuration] 21: 0 => 0 17:22:57.695 SERIAL » [ACK] (0x06) 17:22:57.696 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 21 value size: 1 value: 0 17:22:57.699 SERIAL » 0x010a0013190370052825d652 (12 bytes) 17:22:57.699 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 214 └─[ConfigurationCCGet] parameter #: 40 17:22:57.700 CNTRLR « [Node 024] parameter #21 has value: 0 17:22:57.700 CNTRLR » [Node 024] querying parameter #27 value... 17:22:57.703 SERIAL « [ACK] (0x06) 17:22:57.708 SERIAL « 0x0104011301e8 (6 bytes) 17:22:57.709 SERIAL » [ACK] (0x06) 17:22:57.709 DRIVER « [RES] [SendData] was sent: true 17:22:57.725 SERIAL « 0x01070013d60000023f (9 bytes) 17:22:57.725 SERIAL » [ACK] (0x06) 17:22:57.726 DRIVER « [REQ] [SendData] callback id: 214 transmit status: OK 17:22:57.735 SERIAL « 0x010b00040019057006280103b0 (13 bytes) 17:22:57.740 CNTRLR [Node 025] [~] [Configuration] 40: 3 => 3 17:22:57.741 SERIAL » [ACK] (0x06) 17:22:57.742 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 3 17:22:57.756 SERIAL » 0x010a00131a0370052a25d752 (12 bytes) 17:22:57.756 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 215 └─[ConfigurationCCGet] parameter #: 42 17:22:57.757 CNTRLR « [Node 025] parameter #40 has value: 3 17:22:57.757 CNTRLR » [Node 025] querying parameter #41 value... 17:22:57.760 SERIAL « [ACK] (0x06) 17:22:57.764 SERIAL « 0x0104011301e8 (6 bytes) 17:22:57.765 SERIAL » [ACK] (0x06) 17:22:57.766 DRIVER « [RES] [SendData] was sent: true 17:22:57.803 SERIAL « 0x01070013d700000438 (9 bytes) 17:22:57.803 SERIAL » [ACK] (0x06) 17:22:57.804 DRIVER « [REQ] [SendData] callback id: 215 transmit status: OK 17:22:57.851 SERIAL « 0x010c0004001a0670062a020e10ab (14 bytes) 17:22:57.856 CNTRLR [Node 026] [~] [Configuration] 42: 3600 => 3600 17:22:57.857 SERIAL » [ACK] (0x06) 17:22:57.858 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 3600 17:22:57.861 SERIAL » 0x010a0013170370052925d853 (12 bytes) 17:22:57.862 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 216 └─[ConfigurationCCGet] parameter #: 41 17:22:57.862 CNTRLR « [Node 026] parameter #42 has value: 3600 17:22:57.862 CNTRLR » [Node 026] querying parameter #43 value... 17:22:57.865 SERIAL « [ACK] (0x06) 17:22:57.871 SERIAL « 0x0104011301e8 (6 bytes) 17:22:57.872 SERIAL » [ACK] (0x06) 17:22:57.873 DRIVER « [RES] [SendData] was sent: true 17:22:57.935 SERIAL « 0x01070013d800000734 (9 bytes) 17:22:57.936 SERIAL » [ACK] (0x06) 17:22:57.936 DRIVER « [REQ] [SendData] callback id: 216 transmit status: OK 17:22:57.946 SERIAL « 0x010b00040017057006290102be (13 bytes) 17:22:57.951 CNTRLR [Node 023] [~] [Configuration] 41: 2 => 2 17:22:57.951 SERIAL » [ACK] (0x06) 17:22:57.952 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 41 value size: 1 value: 2 17:22:57.955 SERIAL » 0x010a0013180370051b25d96f (12 bytes) 17:22:57.956 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 217 └─[ConfigurationCCGet] parameter #: 27 17:22:57.956 CNTRLR « [Node 023] parameter #41 has value: 2 17:22:57.956 CNTRLR » [Node 023] querying parameter #42 value... 17:22:57.961 SERIAL « [ACK] (0x06) 17:22:57.964 SERIAL « 0x0104011301e8 (6 bytes) 17:22:57.964 SERIAL » [ACK] (0x06) 17:22:57.965 DRIVER « [RES] [SendData] was sent: true 17:22:57.988 SERIAL « 0x01070013d900000331 (9 bytes) 17:22:57.988 SERIAL » [ACK] (0x06) 17:22:57.989 DRIVER « [REQ] [SendData] callback id: 217 transmit status: OK 17:22:58.002 SERIAL « 0x010b000400180570061b010f8e (13 bytes) 17:22:58.008 CNTRLR [Node 024] [~] [Configuration] 27: 15 => 15 17:22:58.008 SERIAL » [ACK] (0x06) 17:22:58.009 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 27 value size: 1 value: 15 17:22:58.012 SERIAL » 0x010a0013190370052925da5f (12 bytes) 17:22:58.012 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 218 └─[ConfigurationCCGet] parameter #: 41 17:22:58.013 CNTRLR « [Node 024] parameter #27 has value: 15 17:22:58.013 CNTRLR » [Node 024] querying parameter #28 value... 17:22:58.017 SERIAL « [ACK] (0x06) 17:22:58.022 SERIAL « 0x0104011301e8 (6 bytes) 17:22:58.027 SERIAL » [ACK] (0x06) 17:22:58.030 DRIVER « [RES] [SendData] was sent: true 17:22:58.038 SERIAL « 0x01070013da00000233 (9 bytes) 17:22:58.038 SERIAL » [ACK] (0x06) 17:22:58.039 DRIVER « [REQ] [SendData] callback id: 218 transmit status: OK 17:22:58.048 SERIAL « 0x010b00040019057006290102b0 (13 bytes) 17:22:58.053 CNTRLR [Node 025] [~] [Configuration] 41: 2 => 2 17:22:58.054 SERIAL » [ACK] (0x06) 17:22:58.055 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 41 value size: 1 value: 2 17:22:58.058 SERIAL » 0x010a00131a0370052b25db5f (12 bytes) 17:22:58.058 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 219 └─[ConfigurationCCGet] parameter #: 43 17:22:58.059 CNTRLR « [Node 025] parameter #41 has value: 2 17:22:58.059 CNTRLR » [Node 025] querying parameter #42 value... 17:22:58.063 SERIAL « [ACK] (0x06) 17:22:58.067 SERIAL « 0x0104011301e8 (6 bytes) 17:22:58.067 SERIAL » [ACK] (0x06) 17:22:58.068 DRIVER « [RES] [SendData] was sent: true 17:22:58.105 SERIAL « 0x01070013db00000434 (9 bytes) 17:22:58.105 SERIAL » [ACK] (0x06) 17:22:58.106 DRIVER « [REQ] [SendData] callback id: 219 transmit status: OK 17:22:58.153 SERIAL « 0x010b0004001a0570062b010ab9 (13 bytes) 17:22:58.163 CNTRLR [Node 026] [~] [Configuration] 43: 10 => 10 17:22:58.164 SERIAL » [ACK] (0x06) 17:22:58.165 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 10 17:22:58.178 SERIAL » 0x010a0013170370052a25dc54 (12 bytes) 17:22:58.179 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 220 └─[ConfigurationCCGet] parameter #: 42 17:22:58.179 CNTRLR « [Node 026] parameter #43 has value: 10 17:22:58.180 CNTRLR » [Node 026] querying parameter #44 value... 17:22:58.185 SERIAL « [ACK] (0x06) 17:22:58.188 SERIAL « 0x0104011301e8 (6 bytes) 17:22:58.188 SERIAL » [ACK] (0x06) 17:22:58.190 DRIVER « [RES] [SendData] was sent: true 17:22:58.236 SERIAL « 0x01070013dc00000532 (9 bytes) 17:22:58.236 SERIAL » [ACK] (0x06) 17:22:58.237 DRIVER « [REQ] [SendData] callback id: 220 transmit status: OK 17:22:58.246 SERIAL « 0x010b000400170570062a0103bc (13 bytes) 17:22:58.253 CNTRLR [Node 023] [~] [Configuration] 42: 3 => 3 17:22:58.254 SERIAL » [ACK] (0x06) 17:22:58.255 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 3 17:22:58.259 SERIAL » 0x010a0013180370051c25dd6c (12 bytes) 17:22:58.260 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 221 └─[ConfigurationCCGet] parameter #: 28 17:22:58.260 CNTRLR « [Node 023] parameter #42 has value: 3 17:22:58.261 CNTRLR » [Node 023] querying parameter #43 value... 17:22:58.265 SERIAL « [ACK] (0x06) 17:22:58.269 SERIAL « 0x0104011301e8 (6 bytes) 17:22:58.269 SERIAL » [ACK] (0x06) 17:22:58.271 DRIVER « [RES] [SendData] was sent: true 17:22:58.289 SERIAL « 0x01070013dd00000335 (9 bytes) 17:22:58.289 SERIAL » [ACK] (0x06) 17:22:58.290 DRIVER « [REQ] [SendData] callback id: 221 transmit status: OK 17:22:58.303 SERIAL « 0x010b000400180570061c010086 (13 bytes) 17:22:58.310 CNTRLR [Node 024] [~] [Configuration] 28: 0 => 0 17:22:58.311 SERIAL » [ACK] (0x06) 17:22:58.312 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 28 value size: 1 value: 0 17:22:58.316 SERIAL » 0x010a0013190370052a25de58 (12 bytes) 17:22:58.317 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 222 └─[ConfigurationCCGet] parameter #: 42 17:22:58.317 CNTRLR « [Node 024] parameter #28 has value: 0 17:22:58.318 CNTRLR » [Node 024] querying parameter #29 value... 17:22:58.322 SERIAL « [ACK] (0x06) 17:22:58.326 SERIAL « 0x0104011301e8 (6 bytes) 17:22:58.326 SERIAL » [ACK] (0x06) 17:22:58.327 DRIVER « [RES] [SendData] was sent: true 17:22:58.343 SERIAL « 0x01070013de00000237 (9 bytes) 17:22:58.343 SERIAL » [ACK] (0x06) 17:22:58.344 DRIVER « [REQ] [SendData] callback id: 222 transmit status: OK 17:22:58.353 SERIAL « 0x010b000400190570062a0103b2 (13 bytes) 17:22:58.359 CNTRLR [Node 025] [~] [Configuration] 42: 3 => 3 17:22:58.360 SERIAL » [ACK] (0x06) 17:22:58.361 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 3 17:22:58.364 SERIAL » 0x010a00131a0370052c25df5c (12 bytes) 17:22:58.364 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 223 └─[ConfigurationCCGet] parameter #: 44 17:22:58.364 CNTRLR « [Node 025] parameter #42 has value: 3 17:22:58.365 CNTRLR » [Node 025] querying parameter #43 value... 17:22:58.370 SERIAL « [ACK] (0x06) 17:22:58.374 SERIAL « 0x0104011301e8 (6 bytes) 17:22:58.375 SERIAL » [ACK] (0x06) 17:22:58.377 DRIVER « [RES] [SendData] was sent: true 17:22:58.411 SERIAL « 0x01070013df00000531 (9 bytes) 17:22:58.411 SERIAL » [ACK] (0x06) 17:22:58.411 DRIVER « [REQ] [SendData] callback id: 223 transmit status: OK 17:22:58.459 SERIAL « 0x010b0004001a0570062c0100b4 (13 bytes) 17:22:58.464 CNTRLR [Node 026] [~] [Configuration] 44: 0 => 0 17:22:58.464 SERIAL » [ACK] (0x06) 17:22:58.465 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 44 value size: 1 value: 0 17:22:58.468 SERIAL » 0x010a0013170370052b25e069 (12 bytes) 17:22:58.468 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 224 └─[ConfigurationCCGet] parameter #: 43 17:22:58.469 CNTRLR « [Node 026] parameter #44 has value: 0 17:22:58.469 CNTRLR » [Node 026] querying parameter #50 value... 17:22:58.472 SERIAL « [ACK] (0x06) 17:22:58.479 SERIAL « 0x0104011301e8 (6 bytes) 17:22:58.480 SERIAL » [ACK] (0x06) 17:22:58.480 DRIVER « [RES] [SendData] was sent: true 17:22:58.546 SERIAL « 0x01070013e00000070c (9 bytes) 17:22:58.546 SERIAL » [ACK] (0x06) 17:22:58.546 DRIVER « [REQ] [SendData] callback id: 224 transmit status: OK 17:22:58.556 SERIAL « 0x010b000400170570062b0101bf (13 bytes) 17:22:58.561 CNTRLR [Node 023] [~] [Configuration] 43: 1 => 1 17:22:58.562 SERIAL » [ACK] (0x06) 17:22:58.563 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 1 17:22:58.566 SERIAL » 0x010a0013180370051d25e151 (12 bytes) 17:22:58.567 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 225 └─[ConfigurationCCGet] parameter #: 29 17:22:58.567 CNTRLR « [Node 023] parameter #43 has value: 1 17:22:58.568 CNTRLR [Node 023] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:22:58.595 SERIAL « [ACK] (0x06) 17:22:58.600 SERIAL « 0x0104011301e8 (6 bytes) 17:22:58.600 SERIAL » [ACK] (0x06) 17:22:58.603 DRIVER « [RES] [SendData] was sent: true 17:22:58.605 CNTRLR [Node 023] MultiChannelAssociationCC: doing a partial interview... 17:22:58.605 CNTRLR » [Node 023] querying multi channel association group #1... 17:22:58.610 SERIAL « 0x01070013e100000208 (9 bytes) 17:22:58.610 SERIAL » [ACK] (0x06) 17:22:58.611 DRIVER « [REQ] [SendData] callback id: 225 transmit status: OK 17:22:58.613 SERIAL « 0x010b000400180570061d010087 (13 bytes) 17:22:58.618 CNTRLR [Node 024] [~] [Configuration] 29: 0 => 0 17:22:58.619 SERIAL » [ACK] (0x06) 17:22:58.620 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 29 value size: 1 value: 0 17:22:58.624 SERIAL » 0x010a001317038e020125e2b8 (12 bytes) 17:22:58.624 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 226 └─[MultiChannelAssociationCCGet] group id: 1 17:22:58.625 CNTRLR « [Node 024] parameter #29 has value: 0 17:22:58.625 CNTRLR » [Node 024] querying parameter #30 value... 17:22:58.628 SERIAL « [ACK] (0x06) 17:22:58.632 SERIAL « 0x0104011301e8 (6 bytes) 17:22:58.633 SERIAL » [ACK] (0x06) 17:22:58.633 DRIVER « [RES] [SendData] was sent: true 17:22:58.650 SERIAL « 0x01070013e20000030a (9 bytes) 17:22:58.650 SERIAL » [ACK] (0x06) 17:22:58.650 DRIVER « [REQ] [SendData] callback id: 226 transmit status: OK 17:22:58.660 SERIAL « 0x010b00040017058e030105006b (13 bytes) 17:22:58.661 SERIAL » [ACK] (0x06) 17:22:58.661 CNTRLR [Node 023] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 17:22:58.662 CNTRLR [Node 023] [~] [Multi Channel Association] nodeIds[1]: => 17:22:58.663 CNTRLR [Node 023] [~] [Multi Channel Association] endpoints[1]: => 17:22:58.664 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: endpoints: 17:22:58.667 SERIAL » 0x010a0013190370052b25e364 (12 bytes) 17:22:58.667 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 227 └─[ConfigurationCCGet] parameter #: 43 17:22:58.668 CNTRLR « [Node 023] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 17:22:58.668 CNTRLR » [Node 023] querying multi channel association group #2... 17:22:58.671 SERIAL « [ACK] (0x06) 17:22:58.676 SERIAL « 0x0104011301e8 (6 bytes) 17:22:58.677 SERIAL » [ACK] (0x06) 17:22:58.678 DRIVER « [RES] [SendData] was sent: true 17:22:58.693 SERIAL « 0x01070013e30000020a (9 bytes) 17:22:58.693 SERIAL » [ACK] (0x06) 17:22:58.694 DRIVER « [REQ] [SendData] callback id: 227 transmit status: OK 17:22:58.703 SERIAL « 0x010b000400190570062b0101b1 (13 bytes) 17:22:58.709 CNTRLR [Node 025] [~] [Configuration] 43: 1 => 1 17:22:58.709 SERIAL » [ACK] (0x06) 17:22:58.710 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 1 17:22:58.713 SERIAL » 0x010a001317038e020225e4bd (12 bytes) 17:22:58.714 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 228 └─[MultiChannelAssociationCCGet] group id: 2 17:22:58.722 CNTRLR « [Node 025] parameter #43 has value: 1 17:22:58.722 CNTRLR [Node 025] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:22:58.723 CNTRLR [Node 025] MultiChannelAssociationCC: doing a partial interview... 17:22:58.723 CNTRLR » [Node 025] querying multi channel association group #1... 17:22:58.726 SERIAL « [ACK] (0x06) 17:22:58.729 SERIAL « 0x0104011301e8 (6 bytes) 17:22:58.730 SERIAL » [ACK] (0x06) 17:22:58.730 DRIVER « [RES] [SendData] was sent: true 17:22:58.747 SERIAL « 0x01070013e40000020d (9 bytes) 17:22:58.747 SERIAL » [ACK] (0x06) 17:22:58.747 DRIVER « [REQ] [SendData] callback id: 228 transmit status: OK 17:22:58.759 SERIAL « 0x010b00040017058e0302050068 (13 bytes) 17:22:58.759 SERIAL » [ACK] (0x06) 17:22:58.761 CNTRLR [Node 023] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 17:22:58.761 CNTRLR [Node 023] [~] [Multi Channel Association] nodeIds[2]: => 17:22:58.762 CNTRLR [Node 023] [~] [Multi Channel Association] endpoints[2]: => 17:22:58.763 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 17:22:58.766 SERIAL » 0x010a001319038e020125e5b1 (12 bytes) 17:22:58.766 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 229 └─[MultiChannelAssociationCCGet] group id: 1 17:22:58.767 CNTRLR « [Node 023] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 17:22:58.767 CNTRLR » [Node 023] querying additional non-multi-channel association groups... 17:22:58.767 CNTRLR » [Node 023] querying association group #3... 17:22:58.771 SERIAL « [ACK] (0x06) 17:22:58.775 SERIAL « 0x0104011301e8 (6 bytes) 17:22:58.776 SERIAL » [ACK] (0x06) 17:22:58.777 DRIVER « [RES] [SendData] was sent: true 17:22:58.792 SERIAL « 0x01070013e50000020c (9 bytes) 17:22:58.792 SERIAL » [ACK] (0x06) 17:22:58.793 DRIVER « [REQ] [SendData] callback id: 229 transmit status: OK 17:22:58.803 SERIAL « 0x010b00040019058e0301050065 (13 bytes) 17:22:58.803 SERIAL » [ACK] (0x06) 17:22:58.804 CNTRLR [Node 025] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 17:22:58.805 CNTRLR [Node 025] [~] [Multi Channel Association] nodeIds[1]: => 17:22:58.806 CNTRLR [Node 025] [~] [Multi Channel Association] endpoints[1]: => 17:22:58.806 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: endpoints: 17:22:58.809 SERIAL » 0x010a0013170385020325e6b5 (12 bytes) 17:22:58.810 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 230 └─[AssociationCCGet] group id: 3 17:22:58.810 CNTRLR « [Node 025] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 17:22:58.810 CNTRLR » [Node 025] querying multi channel association group #2... 17:22:58.814 SERIAL « [ACK] (0x06) 17:22:58.820 SERIAL « 0x0104011301e8 (6 bytes) 17:22:58.820 SERIAL » [ACK] (0x06) 17:22:58.822 DRIVER « [RES] [SendData] was sent: true 17:22:58.835 SERIAL « 0x01070013e60000020f (9 bytes) 17:22:58.836 SERIAL » [ACK] (0x06) 17:22:58.836 DRIVER « [REQ] [SendData] callback id: 230 transmit status: OK 17:22:58.846 SERIAL « 0x010c000400170685030301000163 (14 bytes) 17:22:58.847 SERIAL » [ACK] (0x06) 17:22:58.848 CNTRLR [Node 023] [~] [Association] maxNodes[3]: 1 => 1 [internal] 17:22:58.848 CNTRLR [Node 023] [~] [Association] nodeIds[3]: 1 => 1 [internal] 17:22:58.848 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 17:22:58.851 SERIAL » 0x010a001319038e020225e7b0 (12 bytes) 17:22:58.852 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 231 └─[MultiChannelAssociationCCGet] group id: 2 17:22:58.852 CNTRLR « [Node 023] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 17:22:58.853 CNTRLR [Node 023] [~] [Association] hasLifeline: true => true [internal] 17:22:58.853 CNTRLR [Node 023] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:22:58.879 SERIAL « [ACK] (0x06) 17:22:58.883 SERIAL « 0x0104011301e8 (6 bytes) 17:22:58.884 SERIAL » [ACK] (0x06) 17:22:58.886 DRIVER « [RES] [SendData] was sent: true 17:22:58.887 CNTRLR [Node 023] Interview stage completed: CommandClasses 17:22:58.887 CNTRLR [Node 023] Interview stage completed: OverwriteConfig 17:22:58.888 CNTRLR » [Node 023] requesting node neighbors... 17:22:58.890 SERIAL « 0x01070013e70000020e (9 bytes) 17:22:58.890 SERIAL » [ACK] (0x06) 17:22:58.891 DRIVER « [REQ] [SendData] callback id: 231 transmit status: OK 17:22:58.894 SERIAL « 0x010b00040019058e0302050066 (13 bytes) 17:22:58.894 SERIAL » [ACK] (0x06) 17:22:58.895 CNTRLR [Node 025] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 17:22:58.896 CNTRLR [Node 025] [~] [Multi Channel Association] nodeIds[2]: => 17:22:58.897 CNTRLR [Node 025] [~] [Multi Channel Association] endpoints[2]: => 17:22:58.898 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 17:22:58.900 SERIAL » 0x01070080170000006f (9 bytes) 17:22:58.901 DRIVER » [Node 023] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:22:58.901 CNTRLR « [Node 025] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 17:22:58.901 CNTRLR » [Node 025] querying additional non-multi-channel association groups... 17:22:58.901 CNTRLR » [Node 025] querying association group #3... 17:22:58.905 SERIAL « [ACK] (0x06) 17:22:58.906 SERIAL « 0x0120018025f2ac570500000000000000000000000000000000000000000000000 (34 bytes) 077 17:22:58.907 SERIAL » [ACK] (0x06) 17:22:58.907 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 10, 13, 14, 15, 16, 19, 20, 22, 24, 25, 26, 27, 29, 31, 3 3, 35 17:22:58.911 SERIAL » 0x010a0013190385020325e8b5 (12 bytes) 17:22:58.911 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 232 └─[AssociationCCGet] group id: 3 17:22:58.912 CNTRLR « [Node 023] node neighbors received: 1, 3, 6, 10, 13, 14, 15, 16, 19, 20, 22, 24, 25, 26, 27, 29, 31, 33, 35 17:22:58.912 CNTRLR [Node 023] Interview stage completed: Neighbors 17:22:58.912 CNTRLR [Node 023] Interview completed 17:22:58.916 SERIAL « [ACK] (0x06) 17:22:58.923 SERIAL « 0x0104011301e8 (6 bytes) 17:22:58.923 SERIAL » [ACK] (0x06) 17:22:58.925 DRIVER « [RES] [SendData] was sent: true 17:22:58.937 SERIAL « 0x01070013e800000201 (9 bytes) 17:22:58.937 SERIAL » [ACK] (0x06) 17:22:58.938 DRIVER « [REQ] [SendData] callback id: 232 transmit status: OK 17:22:58.948 SERIAL « 0x010c00040019068503030100016d (14 bytes) 17:22:58.952 SERIAL » [ACK] (0x06) 17:22:58.953 CNTRLR [Node 025] [~] [Association] maxNodes[3]: 1 => 1 [internal] 17:22:58.953 CNTRLR [Node 025] [~] [Association] nodeIds[3]: 1 => 1 [internal] 17:22:58.953 DRIVER « [Node 025] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 17:22:58.965 SERIAL » 0x010a00131a0370053225e974 (12 bytes) 17:22:58.966 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 233 └─[ConfigurationCCGet] parameter #: 50 17:22:58.967 CNTRLR « [Node 025] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 17:22:58.968 CNTRLR [Node 025] [~] [Association] hasLifeline: true => true [internal] 17:22:58.968 CNTRLR [Node 025] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:22:58.968 CNTRLR [Node 025] Interview stage completed: CommandClasses 17:22:58.969 CNTRLR [Node 025] Interview stage completed: OverwriteConfig 17:22:58.969 CNTRLR » [Node 025] requesting node neighbors... 17:22:58.972 SERIAL « [ACK] (0x06) 17:22:58.974 SERIAL « 0x0104011301e8 (6 bytes) 17:22:58.975 SERIAL » [ACK] (0x06) 17:22:58.975 DRIVER « [RES] [SendData] was sent: true 17:22:59.013 SERIAL « 0x01070013e900000406 (9 bytes) 17:22:59.013 SERIAL » [ACK] (0x06) 17:22:59.014 DRIVER « [REQ] [SendData] callback id: 233 transmit status: OK 17:22:59.061 SERIAL « 0x010b0004001a057006320100aa (13 bytes) 17:22:59.068 CNTRLR [Node 026] [~] [Configuration] 50: 0 => 0 17:22:59.069 SERIAL » [ACK] (0x06) 17:22:59.070 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 0 17:22:59.074 SERIAL » 0x010700801900000061 (9 bytes) 17:22:59.075 DRIVER » [Node 025] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:22:59.075 CNTRLR « [Node 026] parameter #50 has value: 0 17:22:59.075 CNTRLR [Node 026] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:22:59.115 SERIAL « [ACK] (0x06) 17:22:59.116 SERIAL « 0x0120018065f9e47e0700000000000000000000000000000000000000000000000 (34 bytes) 05f 17:22:59.117 SERIAL » [ACK] (0x06) 17:22:59.118 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 9, 12, 13, 14, 15, 16, 19, 22, 23, 24, 26, 27, 28, 29, 30, 31, 33, 34, 35 17:22:59.132 SERIAL » 0x010a0013180370051e25ea59 (12 bytes) 17:22:59.133 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 234 └─[ConfigurationCCGet] parameter #: 30 17:22:59.133 CNTRLR « [Node 025] node neighbors received: 1, 3, 6, 7, 9, 12, 13, 14, 15, 16, 19, 2 2, 23, 24, 26, 27, 28, 29, 30, 31, 33, 34, 35 17:22:59.134 CNTRLR [Node 025] Interview stage completed: Neighbors 17:22:59.134 CNTRLR [Node 025] Interview completed 17:22:59.160 SERIAL « [ACK] (0x06) 17:22:59.161 SERIAL « 0x0104011301e8 (6 bytes) 17:22:59.162 SERIAL » [ACK] (0x06) 17:22:59.164 CNTRLR [Node 026] ProtectionCC: doing a partial interview... 17:22:59.164 CNTRLR » [Node 026] querying protection status... 17:22:59.167 DRIVER « [RES] [SendData] was sent: true 17:22:59.180 SERIAL « 0x01070013ea00000302 (9 bytes) 17:22:59.180 SERIAL » [ACK] (0x06) 17:22:59.182 DRIVER « [REQ] [SendData] callback id: 234 transmit status: OK 17:22:59.186 SERIAL « 0x010b000400180570061e010084 (13 bytes) 17:22:59.192 CNTRLR [Node 024] [~] [Configuration] 30: 0 => 0 17:22:59.193 SERIAL » [ACK] (0x06) 17:22:59.201 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 0 17:22:59.207 SERIAL » 0x010900131a02750225eb44 (11 bytes) 17:22:59.208 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 235 └─[ProtectionCCGet] 17:22:59.209 CNTRLR « [Node 024] parameter #30 has value: 0 17:22:59.209 CNTRLR » [Node 024] querying parameter #31 value... 17:22:59.215 SERIAL « [ACK] (0x06) 17:22:59.220 SERIAL « 0x0104011301e8 (6 bytes) 17:22:59.220 SERIAL » [ACK] (0x06) 17:22:59.221 DRIVER « [RES] [SendData] was sent: true 17:22:59.254 SERIAL « 0x01070013eb00000404 (9 bytes) 17:22:59.254 SERIAL » [ACK] (0x06) 17:22:59.255 DRIVER « [REQ] [SendData] callback id: 235 transmit status: OK 17:22:59.302 SERIAL « 0x010a0004001a047503000099 (12 bytes) 17:22:59.314 CNTRLR [Node 026] [~] [Protection] local: 0 => 0 [Endpoint 0] 17:22:59.315 CNTRLR [Node 026] [~] [Protection] rf: 0 => 0 [Endpoint 0] 17:22:59.315 SERIAL » [ACK] (0x06) 17:22:59.316 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 17:22:59.319 SERIAL » 0x010a0013180370051f25ec5e (12 bytes) 17:22:59.320 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 236 └─[ConfigurationCCGet] parameter #: 31 17:22:59.320 CNTRLR « [Node 026] received protection status: local: Unprotected rf Unprotected 17:22:59.321 CNTRLR [Node 026] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 17:22:59.348 SERIAL « [ACK] (0x06) 17:22:59.352 SERIAL « 0x0104011301e8 (6 bytes) 17:22:59.353 SERIAL » [ACK] (0x06) 17:22:59.354 DRIVER « [RES] [SendData] was sent: true 17:22:59.359 CNTRLR [Node 026] FibaroVenetianBlindCC: doing a partial interview... 17:22:59.359 CNTRLR » [Node 026] Requesting venetian blind position and tilt... 17:22:59.389 SERIAL « 0x01070013ec00000700 (9 bytes) 17:22:59.389 SERIAL » [ACK] (0x06) 17:22:59.390 DRIVER « [REQ] [SendData] callback id: 236 transmit status: OK 17:22:59.404 SERIAL « 0x010c000400180670061f0200ff7d (14 bytes) 17:22:59.409 CNTRLR [Node 024] [~] [Configuration] 31: 255 => 255 17:22:59.410 SERIAL » [ACK] (0x06) 17:22:59.411 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 2 value: 255 17:22:59.414 SERIAL » 0x010800131b010025ed36 (10 bytes) 17:22:59.414 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 237 └─[NoOperationCC] 17:22:59.415 CNTRLR « [Node 024] parameter #31 has value: 255 17:22:59.415 CNTRLR » [Node 024] querying parameter #32 value... 17:22:59.418 SERIAL « [ACK] (0x06) 17:22:59.422 SERIAL « 0x0104011301e8 (6 bytes) 17:22:59.423 SERIAL » [ACK] (0x06) 17:22:59.423 DRIVER « [RES] [SendData] was sent: true 17:23:06.546 SERIAL « 0x01070013ed0102c9cc (9 bytes) 17:23:06.547 SERIAL » [ACK] (0x06) 17:23:06.548 DRIVER « [REQ] [SendData] callback id: 237 transmit status: NoAck 17:23:06.556 SERIAL » 0x010800131c010025ee32 (10 bytes) 17:23:06.557 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 238 └─[NoOperationCC] 17:23:06.557 CNTRLR [Node 027] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 17:23:06.558 CNTRLR [Node 027] The node is asleep. 17:23:06.560 CNTRLR [Node 027] The node is ready to be used 17:23:06.562 CNTRLR [Node 027] ping failed: Failed to send the command after 1 attempts (Status No Ack) 17:23:06.567 CNTRLR [Node 027] ManufacturerSpecificCC: doing a partial interview... 17:23:06.568 CNTRLR [Node 027] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:23:06.617 SERIAL « [ACK] (0x06) 17:23:06.618 SERIAL « 0x0104011301e8 (6 bytes) 17:23:06.618 SERIAL » [ACK] (0x06) 17:23:06.620 DRIVER « [RES] [SendData] was sent: true 17:23:06.624 CNTRLR [Node 027] VersionCC: doing a partial interview... 17:23:06.624 CNTRLR [Node 027] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:23:06.624 CNTRLR [Node 027] trying to load device config 17:23:06.637 CNTRLR [Node 027] device config loaded 17:23:06.638 CNTRLR [Node 027] BatteryCC: doing a partial interview... 17:23:06.638 CNTRLR » [Node 027] querying battery status... 17:23:07.958 SERIAL « 0x01070013ee00008b8e (9 bytes) 17:23:07.959 SERIAL » [ACK] (0x06) 17:23:07.959 DRIVER « [REQ] [SendData] callback id: 238 transmit status: OK 17:23:07.968 SERIAL » 0x010800131d010025ef32 (10 bytes) 17:23:07.969 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 239 └─[NoOperationCC] 17:23:07.969 CNTRLR « [Node 028] ping successful 17:23:07.975 CNTRLR [Node 028] ManufacturerSpecificCC: doing a partial interview... 17:23:07.976 CNTRLR [Node 028] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:23:08.032 SERIAL « [ACK] (0x06) 17:23:08.033 SERIAL « 0x0104011301e8 (6 bytes) 17:23:08.034 SERIAL » [ACK] (0x06) 17:23:08.036 DRIVER « [RES] [SendData] was sent: true 17:23:08.039 CNTRLR [Node 028] VersionCC: doing a partial interview... 17:23:08.039 CNTRLR [Node 028] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:23:08.039 CNTRLR [Node 028] trying to load device config 17:23:08.043 CNTRLR [Node 028] device config loaded 17:23:08.043 CNTRLR [Node 028] ZWavePlusCC: doing a partial interview... 17:23:08.043 CNTRLR [Node 028] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 17:23:08.044 CNTRLR » [Node 028] querying device endpoint information... 17:23:09.437 SERIAL « 0x01070013ef00009296 (9 bytes) 17:23:09.437 SERIAL » [ACK] (0x06) 17:23:09.438 DRIVER « [REQ] [SendData] callback id: 239 transmit status: OK 17:23:09.441 SERIAL » 0x010a0013180370052025f07d (12 bytes) 17:23:09.442 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 240 └─[ConfigurationCCGet] parameter #: 32 17:23:09.442 CNTRLR « [Node 029] ping successful 17:23:09.444 CNTRLR [Node 029] ManufacturerSpecificCC: doing a partial interview... 17:23:09.444 CNTRLR [Node 029] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:23:09.471 SERIAL « [ACK] (0x06) 17:23:09.474 SERIAL « 0x0104011301e8 (6 bytes) 17:23:09.474 SERIAL » [ACK] (0x06) 17:23:09.475 DRIVER « [RES] [SendData] was sent: true 17:23:09.477 CNTRLR [Node 029] VersionCC: doing a partial interview... 17:23:09.477 CNTRLR [Node 029] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:23:09.478 CNTRLR [Node 029] trying to load device config 17:23:09.479 SERIAL « 0x01070013f000000318 (9 bytes) 17:23:09.480 SERIAL » [ACK] (0x06) 17:23:09.480 DRIVER « [REQ] [SendData] callback id: 240 transmit status: OK 17:23:09.483 CNTRLR [Node 029] device config loaded 17:23:09.484 CNTRLR [Node 029] ZWavePlusCC: doing a partial interview... 17:23:09.484 CNTRLR [Node 029] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 17:23:09.485 CNTRLR » [Node 029] querying device endpoint information... 17:23:09.487 SERIAL « 0x010c0004001806700620020000bd (14 bytes) 17:23:09.492 CNTRLR [Node 024] [~] [Configuration] 32: 0 => 0 17:23:09.493 SERIAL » [ACK] (0x06) 17:23:09.494 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 2 value: 0 17:23:09.497 SERIAL » 0x010900131c02600725f148 (11 bytes) 17:23:09.497 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 241 └─[MultiChannelCCEndPointGet] 17:23:09.497 CNTRLR « [Node 024] parameter #32 has value: 0 17:23:09.498 CNTRLR » [Node 024] querying parameter #33 value... 17:23:09.501 SERIAL « [ACK] (0x06) 17:23:09.507 SERIAL « 0x0104011301e8 (6 bytes) 17:23:09.508 SERIAL » [ACK] (0x06) 17:23:09.508 DRIVER « [RES] [SendData] was sent: true 17:23:09.567 SERIAL « 0x01070013f10000061c (9 bytes) 17:23:09.567 SERIAL » [ACK] (0x06) 17:23:09.568 DRIVER « [REQ] [SendData] callback id: 241 transmit status: OK 17:23:09.659 SERIAL « 0x010b0004001c05600800020083 (13 bytes) 17:23:09.660 CNTRLR [Node 028] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 17:23:09.660 CNTRLR [Node 028] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 17:23:09.661 CNTRLR [Node 028] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 17:23:09.661 CNTRLR [Node 028] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 17:23:09.661 SERIAL » [ACK] (0x06) 17:23:09.664 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 17:23:09.668 SERIAL » 0x010900131d02600725f24a (11 bytes) 17:23:09.668 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 242 └─[MultiChannelCCEndPointGet] 17:23:09.669 CNTRLR [Node 028] The node is alive. 17:23:09.669 CNTRLR [Node 028] The node is ready to be used 17:23:09.670 CNTRLR « [Node 028] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 17:23:09.671 CNTRLR » [Node 028] querying all endpoints... 17:23:09.675 SERIAL « [ACK] (0x06) 17:23:09.678 SERIAL « 0x0104011301e8 (6 bytes) 17:23:09.678 SERIAL » [ACK] (0x06) 17:23:09.679 DRIVER « [RES] [SendData] was sent: true 17:23:10.477 SERIAL « 0x01070013f200000d14 (9 bytes) 17:23:10.478 SERIAL » [ACK] (0x06) 17:23:10.479 DRIVER « [REQ] [SendData] callback id: 242 transmit status: OK 17:23:10.482 SERIAL « 0x010b0004001d05600800020082 (13 bytes) 17:23:10.483 CNTRLR [Node 029] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 17:23:10.483 CNTRLR [Node 029] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 17:23:10.483 CNTRLR [Node 029] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 17:23:10.483 CNTRLR [Node 029] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 17:23:10.483 SERIAL » [ACK] (0x06) 17:23:10.484 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 17:23:10.487 SERIAL » 0x010a0013180370052125f37f (12 bytes) 17:23:10.488 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 243 └─[ConfigurationCCGet] parameter #: 33 17:23:10.488 CNTRLR [Node 029] The node is alive. 17:23:10.489 CNTRLR [Node 029] The node is ready to be used 17:23:10.490 CNTRLR « [Node 029] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 17:23:10.490 CNTRLR » [Node 029] querying all endpoints... 17:23:10.495 SERIAL « [ACK] (0x06) 17:23:10.497 SERIAL « 0x0104011301e8 (6 bytes) 17:23:10.498 SERIAL » [ACK] (0x06) 17:23:10.498 DRIVER « [RES] [SendData] was sent: true 17:23:10.518 SERIAL « 0x01070013f30000021a (9 bytes) 17:23:10.518 SERIAL » [ACK] (0x06) 17:23:10.519 DRIVER « [REQ] [SendData] callback id: 243 transmit status: OK 17:23:10.533 SERIAL « 0x010c0004001806700621020063df (14 bytes) 17:23:10.538 CNTRLR [Node 024] [~] [Configuration] 33: 99 => 99 17:23:10.539 SERIAL » [ACK] (0x06) 17:23:10.540 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 2 value: 99 17:23:10.543 SERIAL » 0x010b00131c04600bffff25f445 (13 bytes) 17:23:10.543 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 244 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 17:23:10.544 CNTRLR « [Node 024] parameter #33 has value: 99 17:23:10.544 CNTRLR » [Node 024] querying parameter #35 value... 17:23:10.549 SERIAL « [ACK] (0x06) 17:23:10.551 SERIAL « 0x0104011301e8 (6 bytes) 17:23:10.552 SERIAL » [ACK] (0x06) 17:23:10.552 DRIVER « [RES] [SendData] was sent: true 17:23:11.926 SERIAL « 0x01070013f400008a95 (9 bytes) 17:23:11.926 SERIAL » [ACK] (0x06) 17:23:11.927 DRIVER « [REQ] [SendData] callback id: 244 transmit status: OK 17:23:12.016 SERIAL « 0x010d0004001c07600c00ffff010282 (15 bytes) 17:23:12.016 SERIAL » [ACK] (0x06) 17:23:12.018 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 17:23:12.021 SERIAL » 0x010b00131d04600bffff25f545 (13 bytes) 17:23:12.022 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 245 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 17:23:12.023 CNTRLR « [Node 028] received endpoints: 1, 2 17:23:12.023 CNTRLR » [Node 028] querying capabilities for endpoint #1... 17:23:12.026 SERIAL « [ACK] (0x06) 17:23:12.030 SERIAL « 0x0104011301e8 (6 bytes) 17:23:12.031 SERIAL » [ACK] (0x06) 17:23:12.031 DRIVER « [RES] [SendData] was sent: true 17:23:13.539 SERIAL « 0x01070013f500009886 (9 bytes) 17:23:13.540 SERIAL » [ACK] (0x06) 17:23:13.540 DRIVER « [REQ] [SendData] callback id: 245 transmit status: OK 17:23:13.622 SERIAL « 0x010d0004001d07600c00ffff010283 (15 bytes) 17:23:13.623 SERIAL » [ACK] (0x06) 17:23:13.624 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 17:23:13.632 SERIAL » 0x010a0013180370052325f678 (12 bytes) 17:23:13.633 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 246 └─[ConfigurationCCGet] parameter #: 35 17:23:13.635 CNTRLR « [Node 029] received endpoints: 1, 2 17:23:13.635 CNTRLR » [Node 029] querying capabilities for endpoint #1... 17:23:13.642 SERIAL « [ACK] (0x06) 17:23:13.644 SERIAL « 0x0104011301e8 (6 bytes) 17:23:13.645 SERIAL » [ACK] (0x06) 17:23:13.646 DRIVER « [RES] [SendData] was sent: true 17:23:13.719 SERIAL « 0x01070013f600000914 (9 bytes) 17:23:13.719 SERIAL » [ACK] (0x06) 17:23:13.720 DRIVER « [REQ] [SendData] callback id: 246 transmit status: OK 17:23:13.733 SERIAL « 0x010b00040018057006230100b9 (13 bytes) 17:23:13.741 CNTRLR [Node 024] [~] [Configuration] 35: 0 => 0 17:23:13.742 SERIAL » [ACK] (0x06) 17:23:13.743 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 0 17:23:13.747 SERIAL » 0x010a00131c0360090125f743 (12 bytes) 17:23:13.748 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 247 └─[MultiChannelCCCapabilityGet] endpoint: 1 17:23:13.748 CNTRLR « [Node 024] parameter #35 has value: 0 17:23:13.749 CNTRLR » [Node 024] querying parameter #36 value... 17:23:13.753 SERIAL « [ACK] (0x06) 17:23:13.756 SERIAL « 0x0104011301e8 (6 bytes) 17:23:13.757 SERIAL » [ACK] (0x06) 17:23:13.758 DRIVER « [RES] [SendData] was sent: true 17:23:13.887 SERIAL « 0x010c0004000306310504220809e1 (14 bytes) 17:23:13.889 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:23:13.890 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 244.3 => 205.7 [Endpoint 0] 17:23:13.891 SERIAL » [ACK] (0x06) 17:23:13.893 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 205.7 17:23:15.301 SERIAL « 0x01070013f700009b87 (9 bytes) 17:23:15.301 SERIAL » [ACK] (0x06) 17:23:15.301 DRIVER « [REQ] [SendData] callback id: 247 transmit status: OK 17:23:15.392 SERIAL « 0x011a0004001c14600a0108065e8e404353989f596c7175808185229c (28 bytes) 17:23:15.393 CNTRLR [Node 028] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 1] [internal] 64,67,83,152,159,89,108,113,117,128,129,133,34 => 94,142,64,67,83,152,159,89,1 08,113,117,128,129,133,34 17:23:15.393 SERIAL » [ACK] (0x06) 17:23:15.394 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 17:23:15.397 SERIAL » 0x010a00131d0360090125f84d (12 bytes) 17:23:15.397 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 248 └─[MultiChannelCCCapabilityGet] endpoint: 1 17:23:15.398 CNTRLR « [Node 028] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 17:23:15.398 CNTRLR » [Node 028] querying capabilities for endpoint #2... 17:23:15.400 SERIAL « [ACK] (0x06) 17:23:15.405 SERIAL « 0x0104011301e8 (6 bytes) 17:23:15.405 SERIAL » [ACK] (0x06) 17:23:15.406 DRIVER « [RES] [SendData] was sent: true 17:23:16.920 SERIAL « 0x01070013f80000988b (9 bytes) 17:23:16.921 SERIAL » [ACK] (0x06) 17:23:16.922 DRIVER « [REQ] [SendData] callback id: 248 transmit status: OK 17:23:17.015 SERIAL « 0x011a0004001d14600a0108065e8e404353989f596c7175808185229d (28 bytes) 17:23:17.016 CNTRLR [Node 029] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 1] [internal] 64,67,83,152,159,89,108,113,117,128,129,133,34 => 94,142,64,67,83,152,159,89,1 08,113,117,128,129,133,34 17:23:17.017 SERIAL » [ACK] (0x06) 17:23:17.024 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 17:23:17.029 SERIAL » 0x010a0013180370052425f970 (12 bytes) 17:23:17.030 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 249 └─[ConfigurationCCGet] parameter #: 36 17:23:17.031 CNTRLR « [Node 029] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 17:23:17.031 CNTRLR » [Node 029] querying capabilities for endpoint #2... 17:23:17.035 SERIAL « [ACK] (0x06) 17:23:17.038 SERIAL « 0x0104011301e8 (6 bytes) 17:23:17.039 SERIAL » [ACK] (0x06) 17:23:17.039 DRIVER « [RES] [SendData] was sent: true 17:23:17.109 SERIAL « 0x01070013f90000081a (9 bytes) 17:23:17.109 SERIAL » [ACK] (0x06) 17:23:17.110 DRIVER « [REQ] [SendData] callback id: 249 transmit status: OK 17:23:17.124 SERIAL « 0x010c00040018067006240200ff46 (14 bytes) 17:23:17.133 CNTRLR [Node 024] [~] [Configuration] 36: 255 => 255 17:23:17.135 SERIAL » [ACK] (0x06) 17:23:17.136 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 36 value size: 2 value: 255 17:23:17.141 SERIAL » 0x010a00131c0360090225fa4d (12 bytes) 17:23:17.142 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 250 └─[MultiChannelCCCapabilityGet] endpoint: 2 17:23:17.142 CNTRLR « [Node 024] parameter #36 has value: 255 17:23:17.143 CNTRLR » [Node 024] querying parameter #37 value... 17:23:17.148 SERIAL « [ACK] (0x06) 17:23:17.150 SERIAL « 0x0104011301e8 (6 bytes) 17:23:17.152 SERIAL » [ACK] (0x06) 17:23:17.153 DRIVER « [RES] [SendData] was sent: true 17:23:18.558 SERIAL « 0x01070013fa00008d9c (9 bytes) 17:23:18.558 SERIAL » [ACK] (0x06) 17:23:18.559 DRIVER « [REQ] [SendData] callback id: 250 transmit status: OK 17:23:18.643 SERIAL « 0x01160004001c10600a0221015e8e31989f596c718085222c (24 bytes) 17:23:18.645 CNTRLR [Node 028] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 2] [internal] 49,152,159,89,108,113,128,133,34 => 94,142,49,152,159,89,108,113,128,133,34 17:23:18.645 SERIAL » [ACK] (0x06) 17:23:18.646 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 17:23:18.656 SERIAL » 0x010a00131d0360090225fb4d (12 bytes) 17:23:18.657 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 251 └─[MultiChannelCCCapabilityGet] endpoint: 2 17:23:18.657 CNTRLR « [Node 028] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 17:23:18.658 CNTRLR [Node 028] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 17:23:18.708 SERIAL « [ACK] (0x06) 17:23:18.715 SERIAL « 0x0104011301e8 (6 bytes) 17:23:18.715 SERIAL » [ACK] (0x06) 17:23:18.717 DRIVER « [RES] [SendData] was sent: true 17:23:18.720 CNTRLR [Node 028] BatteryCC: doing a partial interview... 17:23:18.721 CNTRLR » [Node 028] querying battery status... 17:23:18.985 SERIAL « 0x010c00040003063105042206a147 (14 bytes) 17:23:18.986 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:23:18.987 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 205.7 => 169.7 [Endpoint 0] 17:23:18.987 SERIAL » [ACK] (0x06) 17:23:18.988 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 169.7 17:23:21.389 SERIAL « 0x01070013fb00011100 (9 bytes) 17:23:21.390 SERIAL » [ACK] (0x06) 17:23:21.390 DRIVER « [REQ] [SendData] callback id: 251 transmit status: OK 17:23:21.476 SERIAL « 0x01160004001d10600a0221015e8e31989f596c718085222d (24 bytes) 17:23:21.476 CNTRLR [Node 029] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 2] [internal] 49,152,159,89,108,113,128,133,34 => 94,142,49,152,159,89,108,113,128,133,34 17:23:21.477 SERIAL » [ACK] (0x06) 17:23:21.477 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 17:23:21.480 SERIAL » 0x010a0013180370052525fc74 (12 bytes) 17:23:21.481 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 252 └─[ConfigurationCCGet] parameter #: 37 17:23:21.481 CNTRLR « [Node 029] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 17:23:21.481 CNTRLR [Node 029] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 17:23:21.511 SERIAL « [ACK] (0x06) 17:23:21.514 SERIAL « 0x0104011301e8 (6 bytes) 17:23:21.515 SERIAL » [ACK] (0x06) 17:23:21.515 DRIVER « [RES] [SendData] was sent: true 17:23:21.518 CNTRLR [Node 029] BatteryCC: doing a partial interview... 17:23:21.518 CNTRLR » [Node 029] querying battery status... 17:23:21.569 SERIAL « 0x01070013fc0000091e (9 bytes) 17:23:21.569 SERIAL » [ACK] (0x06) 17:23:21.570 DRIVER « [REQ] [SendData] callback id: 252 transmit status: OK 17:23:21.584 SERIAL « 0x010c0004001806700625020000b8 (14 bytes) 17:23:21.593 CNTRLR [Node 024] [~] [Configuration] 37: 0 => 0 17:23:21.595 SERIAL » [ACK] (0x06) 17:23:21.596 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 37 value size: 2 value: 0 17:23:21.601 SERIAL » 0x010900131c02800225fda1 (11 bytes) 17:23:21.602 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 253 └─[BatteryCCGet] 17:23:21.602 CNTRLR « [Node 024] parameter #37 has value: 0 17:23:21.603 CNTRLR » [Node 024] querying parameter #38 value... 17:23:21.607 SERIAL « [ACK] (0x06) 17:23:21.610 SERIAL « 0x0104011301e8 (6 bytes) 17:23:21.611 SERIAL » [ACK] (0x06) 17:23:21.612 DRIVER « [RES] [SendData] was sent: true 17:23:23.016 SERIAL « 0x01070013fd00008d9b (9 bytes) 17:23:23.017 SERIAL » [ACK] (0x06) 17:23:23.018 DRIVER « [REQ] [SendData] callback id: 253 transmit status: OK 17:23:23.128 SERIAL « 0x01090004001c038003620c (11 bytes) 17:23:23.130 CNTRLR [Node 028] [~] [Battery] level: 98 => 98 [Endpoint 0] 17:23:23.131 CNTRLR [Node 028] [~] [Battery] isLow: false => false [Endpoint 0] 17:23:23.132 SERIAL » [ACK] (0x06) 17:23:23.134 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 98 is low: false 17:23:23.140 SERIAL » 0x010900131d02800225fea3 (11 bytes) 17:23:23.141 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 254 └─[BatteryCCGet] 17:23:23.142 CNTRLR « [Node 028] received response for battery information: level: 98 17:23:23.142 CNTRLR [Node 028] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:23:23.206 SERIAL « [ACK] (0x06) 17:23:23.215 SERIAL « 0x0104011301e8 (6 bytes) 17:23:23.215 SERIAL » [ACK] (0x06) 17:23:23.218 DRIVER « [RES] [SendData] was sent: true 17:23:23.225 CNTRLR [Node 028] ZWavePlusCC: doing a partial interview... [Endpoint 1] 17:23:23.226 CNTRLR [Node 028] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 17:23:23.227 CNTRLR [Node 028] ThermostatModeCC: doing a partial interview... [Endpoint 1] 17:23:23.227 CNTRLR » [Node 028] querying current thermostat mode... [Endpoint 1] 17:23:23.232 SERIAL « 0x01090004001b032001ff34 (11 bytes) 17:23:23.233 SERIAL » [ACK] (0x06) 17:23:23.235 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:23:23.236 CNTRLR [Node 027] treating BasicCC Set as a report 17:23:23.236 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:23:24.717 SERIAL « 0x01070013fe00009d88 (9 bytes) 17:23:24.717 SERIAL » [ACK] (0x06) 17:23:24.718 DRIVER « [REQ] [SendData] callback id: 254 transmit status: OK 17:23:24.830 SERIAL « 0x01090004001d0380035e31 (11 bytes) 17:23:24.831 CNTRLR [Node 029] [~] [Battery] level: 95 => 94 [Endpoint 0] 17:23:24.832 CNTRLR [Node 029] [~] [Battery] isLow: false => false [Endpoint 0] 17:23:24.833 SERIAL » [ACK] (0x06) 17:23:24.835 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 94 is low: false 17:23:24.848 SERIAL » 0x010a0013180370052625ff74 (12 bytes) 17:23:24.849 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 255 └─[ConfigurationCCGet] parameter #: 38 17:23:24.850 CNTRLR « [Node 029] received response for battery information: level: 94 17:23:24.850 CNTRLR [Node 029] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:23:24.918 SERIAL « [ACK] (0x06) 17:23:24.921 SERIAL « 0x0104011301e8 (6 bytes) 17:23:24.921 SERIAL » [ACK] (0x06) 17:23:24.923 DRIVER « [RES] [SendData] was sent: true 17:23:24.924 SERIAL « 0x01070013ff00000713 (9 bytes) 17:23:24.925 SERIAL » [ACK] (0x06) 17:23:24.927 CNTRLR [Node 029] ZWavePlusCC: doing a partial interview... [Endpoint 1] 17:23:24.927 CNTRLR [Node 029] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 17:23:24.927 CNTRLR [Node 029] ThermostatModeCC: doing a partial interview... [Endpoint 1] 17:23:24.928 CNTRLR » [Node 029] querying current thermostat mode... [Endpoint 1] 17:23:24.930 DRIVER « [REQ] [SendData] callback id: 255 transmit status: OK 17:23:24.934 SERIAL « 0x010c0004001806700626020063d8 (14 bytes) 17:23:24.939 CNTRLR [Node 024] [~] [Configuration] 38: 99 => 99 17:23:24.940 SERIAL » [ACK] (0x06) 17:23:24.941 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 38 value size: 2 value: 99 17:23:24.945 SERIAL » 0x010d00131c06600d000140022501f1 (15 bytes) 17:23:24.946 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 1 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 17:23:24.946 CNTRLR « [Node 024] parameter #38 has value: 99 17:23:24.947 CNTRLR » [Node 024] querying parameter #40 value... 17:23:24.950 SERIAL « [ACK] (0x06) 17:23:24.954 SERIAL « 0x0104011301e8 (6 bytes) 17:23:24.955 SERIAL » [ACK] (0x06) 17:23:24.955 DRIVER « [RES] [SendData] was sent: true 17:23:26.331 SERIAL « 0x010700130100008a60 (9 bytes) 17:23:26.331 SERIAL » [ACK] (0x06) 17:23:26.332 DRIVER « [REQ] [SendData] callback id: 1 transmit status: OK 17:23:26.444 SERIAL « 0x010d0004001c07600d0100400301c3 (15 bytes) 17:23:26.446 CNTRLR [Node 028] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 17:23:26.447 SERIAL » [ACK] (0x06) 17:23:26.449 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 17:23:26.456 SERIAL » 0x010d00131d06600d000140022502f3 (15 bytes) 17:23:26.456 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 2 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 17:23:26.457 CNTRLR « [Node 028] received current thermostat mode: Heat [Endpoint 1] 17:23:26.458 CNTRLR [Node 028] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 1] [internal] ue => true 17:23:26.509 SERIAL « [ACK] (0x06) 17:23:26.514 SERIAL « 0x0104011301e8 (6 bytes) 17:23:26.514 SERIAL » [ACK] (0x06) 17:23:26.515 DRIVER « [RES] [SendData] was sent: true 17:23:26.519 CNTRLR [Node 028] ThermostatSetpointCC: doing a partial interview... [Endpoint 1] 17:23:26.519 CNTRLR » [Node 028] querying current value of setpoint Heating... [Endpoint 1] 17:23:28.021 SERIAL « 0x010700130200009c75 (9 bytes) 17:23:28.021 SERIAL » [ACK] (0x06) 17:23:28.022 DRIVER « [REQ] [SendData] callback id: 2 transmit status: OK 17:23:28.137 SERIAL « 0x010d0004001d07600d0100400301c2 (15 bytes) 17:23:28.138 CNTRLR [Node 029] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 17:23:28.139 SERIAL » [ACK] (0x06) 17:23:28.141 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 17:23:28.147 SERIAL » 0x010a00131803700528250386 (12 bytes) 17:23:28.148 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 3 └─[ConfigurationCCGet] parameter #: 40 17:23:28.149 CNTRLR « [Node 029] received current thermostat mode: Heat [Endpoint 1] 17:23:28.150 CNTRLR [Node 029] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 1] [internal] ue => true 17:23:28.220 SERIAL « [ACK] (0x06) 17:23:28.225 SERIAL « 0x0104011301e8 (6 bytes) 17:23:28.226 SERIAL » [ACK] (0x06) 17:23:28.228 DRIVER « [RES] [SendData] was sent: true 17:23:28.230 CNTRLR [Node 029] ThermostatSetpointCC: doing a partial interview... [Endpoint 1] 17:23:28.230 CNTRLR » [Node 029] querying current value of setpoint Heating... [Endpoint 1] 17:23:28.232 SERIAL « 0x0107001303000008e0 (9 bytes) 17:23:28.232 SERIAL » [ACK] (0x06) 17:23:28.233 DRIVER « [REQ] [SendData] callback id: 3 transmit status: OK 17:23:28.243 SERIAL « 0x010b00040018057006280103b1 (13 bytes) 17:23:28.249 CNTRLR [Node 024] [~] [Configuration] 40: 3 => 3 17:23:28.250 SERIAL » [ACK] (0x06) 17:23:28.251 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 3 17:23:28.254 SERIAL » 0x010e00131c07600d00014302012504f4 (16 bytes) 17:23:28.254 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 4 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 17:23:28.255 CNTRLR « [Node 024] parameter #40 has value: 3 17:23:28.255 CNTRLR » [Node 024] querying parameter #41 value... 17:23:28.261 SERIAL « [ACK] (0x06) 17:23:28.265 SERIAL « 0x0104011301e8 (6 bytes) 17:23:28.266 SERIAL » [ACK] (0x06) 17:23:28.268 DRIVER « [RES] [SendData] was sent: true 17:23:29.693 SERIAL « 0x01070013040000907f (9 bytes) 17:23:29.694 SERIAL » [ACK] (0x06) 17:23:29.695 DRIVER « [REQ] [SendData] callback id: 4 transmit status: OK 17:23:29.815 SERIAL « 0x01100004001c0a600d010043030122006496 (18 bytes) 17:23:29.817 CNTRLR [Node 028] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 1] 17:23:29.818 CNTRLR [Node 028] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 17:23:29.818 SERIAL » [ACK] (0x06) 17:23:29.820 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 17:23:29.826 SERIAL » 0x010e00131d07600d00014302012505f4 (16 bytes) 17:23:29.826 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 5 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 17:23:29.827 CNTRLR « [Node 028] received current value of setpoint Heating: 10 °C [Endpoint 1] 17:23:29.828 CNTRLR [Node 028] [~] [Thermostat Setpoint] interviewComplete [Endpoint 1] [internal] : true => true 17:23:29.899 SERIAL « [ACK] (0x06) 17:23:29.905 SERIAL « 0x0104011301e8 (6 bytes) 17:23:29.906 SERIAL » [ACK] (0x06) 17:23:29.908 DRIVER « [RES] [SendData] was sent: true 17:23:29.913 CNTRLR [Node 028] NotificationCC: doing a partial interview... [Endpoint 1] 17:23:29.913 CNTRLR [Node 028] [~] [Notification] interviewComplete: true [Endpoint 1] [internal] => true 17:23:29.914 CNTRLR [Node 028] ProtectionCC: doing a partial interview... 17:23:29.915 CNTRLR » [Node 028] querying protection status... 17:23:31.358 SERIAL « 0x010700130500009876 (9 bytes) 17:23:31.358 SERIAL » [ACK] (0x06) 17:23:31.359 DRIVER « [REQ] [SendData] callback id: 5 transmit status: OK 17:23:31.482 SERIAL « 0x01100004001d0a600d010043030122006497 (18 bytes) 17:23:31.484 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 1] 17:23:31.485 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 17:23:31.486 SERIAL » [ACK] (0x06) 17:23:31.487 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 17:23:31.494 SERIAL » 0x010a00131803700529250682 (12 bytes) 17:23:31.495 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 6 └─[ConfigurationCCGet] parameter #: 41 17:23:31.495 CNTRLR « [Node 029] received current value of setpoint Heating: 10 °C [Endpoint 1] 17:23:31.496 CNTRLR [Node 029] [~] [Thermostat Setpoint] interviewComplete [Endpoint 1] [internal] : true => true 17:23:31.560 SERIAL « [ACK] (0x06) 17:23:31.568 SERIAL « 0x0104011301e8 (6 bytes) 17:23:31.568 SERIAL » [ACK] (0x06) 17:23:31.570 DRIVER « [RES] [SendData] was sent: true 17:23:31.576 CNTRLR [Node 029] NotificationCC: doing a partial interview... [Endpoint 1] 17:23:31.577 CNTRLR » [Node 029] querying notification status for Power Management... [Endpoint 1] 17:23:31.582 SERIAL « 0x0107001306000009e4 (9 bytes) 17:23:31.583 SERIAL » [ACK] (0x06) 17:23:31.584 DRIVER « [REQ] [SendData] callback id: 6 transmit status: OK 17:23:31.593 SERIAL « 0x010b00040018057006290102b1 (13 bytes) 17:23:31.599 CNTRLR [Node 024] [~] [Configuration] 41: 2 => 2 17:23:31.599 SERIAL » [ACK] (0x06) 17:23:31.600 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 41 value size: 1 value: 2 17:23:31.603 SERIAL » 0x010d00131c06600d000175022507c2 (15 bytes) 17:23:31.604 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 7 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 17:23:31.604 CNTRLR « [Node 024] parameter #41 has value: 2 17:23:31.604 CNTRLR » [Node 024] querying parameter #42 value... 17:23:31.607 SERIAL « [ACK] (0x06) 17:23:31.613 SERIAL « 0x0104011301e8 (6 bytes) 17:23:31.613 SERIAL » [ACK] (0x06) 17:23:31.623 DRIVER « [RES] [SendData] was sent: true 17:23:32.989 SERIAL « 0x010700130700008a66 (9 bytes) 17:23:32.989 SERIAL » [ACK] (0x06) 17:23:32.991 DRIVER « [REQ] [SendData] callback id: 7 transmit status: OK 17:23:33.103 SERIAL « 0x010d0004001c07600d0100750300f7 (15 bytes) 17:23:33.105 CNTRLR [Node 028] [~] [Protection] local: 0 => 0 [Endpoint 1] 17:23:33.105 SERIAL » [ACK] (0x06) 17:23:33.106 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ProtectionCCReport] local: Unprotected 17:23:33.110 SERIAL » 0x011000131d09600d000171040008002508d4 (18 bytes) 17:23:33.111 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 8 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: Power Management 17:23:33.112 CNTRLR « [Node 028] received protection status: local: Unprotected 17:23:33.112 CNTRLR [Node 028] [~] [Protection] interviewComplete: true => [Endpoint 1] [internal] true 17:23:33.155 SERIAL « [ACK] (0x06) 17:23:33.156 SERIAL « 0x0104011301e8 (6 bytes) 17:23:33.156 SERIAL » [ACK] (0x06) 17:23:33.157 DRIVER « [RES] [SendData] was sent: true 17:23:33.160 CNTRLR [Node 028] BatteryCC: doing a partial interview... [Endpoint 1] 17:23:33.160 CNTRLR » [Node 028] querying battery status... [Endpoint 1] 17:23:34.651 SERIAL « 0x010700130800009a79 (9 bytes) 17:23:34.651 SERIAL » [ACK] (0x06) 17:23:34.651 DRIVER « [REQ] [SendData] callback id: 8 transmit status: OK 17:23:34.736 SERIAL « 0x01130004001d0d600d01007105000000ff08fe00e9 (21 bytes) 17:23:34.737 SERIAL » [ACK] (0x06) 17:23:34.738 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 17:23:34.741 SERIAL » 0x010a0013180370052a25098e (12 bytes) 17:23:34.741 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 9 └─[ConfigurationCCGet] parameter #: 42 17:23:34.742 CNTRLR [Node 029] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 1] 54 17:23:34.743 CNTRLR » [Node 029] querying notification status for System... [Endpoint 1] 17:23:34.746 SERIAL « [ACK] (0x06) 17:23:34.749 SERIAL « 0x0104011301e8 (6 bytes) 17:23:34.749 SERIAL » [ACK] (0x06) 17:23:34.750 DRIVER « [RES] [SendData] was sent: true 17:23:34.829 SERIAL « 0x0107001309000009eb (9 bytes) 17:23:34.830 SERIAL » [ACK] (0x06) 17:23:34.831 DRIVER « [REQ] [SendData] callback id: 9 transmit status: OK 17:23:34.843 SERIAL « 0x010b000400180570062a0103b3 (13 bytes) 17:23:34.855 CNTRLR [Node 024] [~] [Configuration] 42: 3 => 3 17:23:34.858 SERIAL » [ACK] (0x06) 17:23:34.860 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 3 17:23:34.866 SERIAL » 0x010d00131c06600d00018002250a3a (15 bytes) 17:23:34.867 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 10 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BatteryCCGet] 17:23:34.867 CNTRLR « [Node 024] parameter #42 has value: 3 17:23:34.868 CNTRLR » [Node 024] querying parameter #43 value... 17:23:34.881 SERIAL « [ACK] (0x06) 17:23:34.883 SERIAL « 0x0104011301e8 (6 bytes) 17:23:34.883 SERIAL » [ACK] (0x06) 17:23:34.885 DRIVER « [RES] [SendData] was sent: true 17:23:36.253 SERIAL « 0x010700130a00008a6b (9 bytes) 17:23:36.253 SERIAL » [ACK] (0x06) 17:23:36.254 DRIVER « [REQ] [SendData] callback id: 10 transmit status: OK 17:23:36.367 SERIAL « 0x010d0004001c07600d010080036260 (15 bytes) 17:23:36.369 CNTRLR [Node 028] [~] [Battery] level: 98 => 98 [Endpoint 1] 17:23:36.370 CNTRLR [Node 028] [~] [Battery] isLow: false => false [Endpoint 1] 17:23:36.371 SERIAL » [ACK] (0x06) 17:23:36.374 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BatteryCCReport] level: 98 is low: false 17:23:36.381 SERIAL » 0x011000131d09600d00017104000900250bd6 (18 bytes) 17:23:36.382 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 11 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: System 17:23:36.383 CNTRLR « [Node 028] received response for battery information: [Endpoint 1] level: 98 17:23:36.383 CNTRLR [Node 028] [~] [Battery] interviewComplete: true => tr [Endpoint 1] [internal] ue 17:23:36.451 SERIAL « [ACK] (0x06) 17:23:36.458 SERIAL « 0x0104011301e8 (6 bytes) 17:23:36.459 SERIAL » [ACK] (0x06) 17:23:36.460 DRIVER « [RES] [SendData] was sent: true 17:23:36.466 CNTRLR [Node 028] ClockCC: doing a partial interview... 17:23:36.466 CNTRLR » [Node 028] requesting current clock setting... 17:23:37.981 SERIAL « 0x010700130b0000a040 (9 bytes) 17:23:37.982 SERIAL » [ACK] (0x06) 17:23:37.983 DRIVER « [REQ] [SendData] callback id: 11 transmit status: OK 17:23:38.067 SERIAL « 0x01130004001d0d600d01007105000000ff09fe00e8 (21 bytes) 17:23:38.069 SERIAL » [ACK] (0x06) 17:23:38.070 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: System notification status: 255 notification event: Unknown (0xfe) 17:23:38.077 SERIAL » 0x010a0013180370052b250c8a (12 bytes) 17:23:38.078 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 12 └─[ConfigurationCCGet] parameter #: 43 17:23:38.079 CNTRLR [Node 029] [~] [Notification] System[unknown]: 254 => 254 [Endpoint 1] 17:23:38.080 CNTRLR [Node 029] [~] [Notification] interviewComplete: true [Endpoint 1] [internal] => true 17:23:38.151 SERIAL « [ACK] (0x06) 17:23:38.160 SERIAL « 0x0104011301e8 (6 bytes) 17:23:38.160 SERIAL » [ACK] (0x06) 17:23:38.165 DRIVER « [RES] [SendData] was sent: true 17:23:38.168 CNTRLR [Node 029] ProtectionCC: doing a partial interview... 17:23:38.169 CNTRLR » [Node 029] querying protection status... 17:23:38.173 SERIAL « 0x010700130c000008ef (9 bytes) 17:23:38.174 SERIAL » [ACK] (0x06) 17:23:38.174 DRIVER « [REQ] [SendData] callback id: 12 transmit status: OK 17:23:38.176 SERIAL « 0x010b000400180570062b0101b0 (13 bytes) 17:23:38.181 CNTRLR [Node 024] [~] [Configuration] 43: 1 => 1 17:23:38.183 SERIAL » [ACK] (0x06) 17:23:38.183 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 1 17:23:38.186 SERIAL » 0x010d00131c06600d00018105250d3b (15 bytes) 17:23:38.187 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 13 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ClockCCGet] 17:23:38.187 CNTRLR « [Node 024] parameter #43 has value: 1 17:23:38.188 CNTRLR » [Node 024] querying parameter #44 value... 17:23:38.194 SERIAL « [ACK] (0x06) 17:23:38.197 SERIAL « 0x0104011301e8 (6 bytes) 17:23:38.197 SERIAL » [ACK] (0x06) 17:23:38.199 DRIVER « [RES] [SendData] was sent: true 17:23:39.572 SERIAL « 0x010700130d00008a6c (9 bytes) 17:23:39.573 SERIAL » [ACK] (0x06) 17:23:39.574 DRIVER « [REQ] [SendData] callback id: 13 transmit status: OK 17:23:39.691 SERIAL « 0x010e0004001c08600d01008106721068 (16 bytes) 17:23:39.692 SERIAL » [ACK] (0x06) 17:23:39.693 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ClockCCReport] clock setting: Wednesday, 18:16 17:23:39.700 SERIAL » 0x010d00131d06600d00017502250eca (15 bytes) 17:23:39.701 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 14 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 17:23:39.701 CNTRLR « [Node 028] received current clock setting: Wednesday, 18:16 17:23:39.702 CNTRLR [Node 028] [~] [Clock] interviewComplete: true => true [Endpoint 1] [internal] 17:23:39.764 SERIAL « [ACK] (0x06) 17:23:39.770 SERIAL « 0x0104011301e8 (6 bytes) 17:23:39.771 SERIAL » [ACK] (0x06) 17:23:39.772 DRIVER « [RES] [SendData] was sent: true 17:23:39.780 CNTRLR [Node 028] ZWavePlusCC: doing a partial interview... [Endpoint 2] 17:23:39.780 CNTRLR [Node 028] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 17:23:39.781 CNTRLR [Node 028] MultilevelSensorCC: doing a partial interview... [Endpoint 2] 17:23:39.782 CNTRLR » [Node 028] querying Air temperature sensor reading... [Endpoint 2] 17:23:41.306 SERIAL « 0x010700130e0000a045 (9 bytes) 17:23:41.307 SERIAL » [ACK] (0x06) 17:23:41.308 DRIVER « [REQ] [SendData] callback id: 14 transmit status: OK 17:23:41.421 SERIAL « 0x010d0004001d07600d0100750300f6 (15 bytes) 17:23:41.423 CNTRLR [Node 029] [~] [Protection] local: 0 => 0 [Endpoint 1] 17:23:41.424 SERIAL » [ACK] (0x06) 17:23:41.425 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ProtectionCCReport] local: Unprotected 17:23:41.432 SERIAL » 0x010a0013180370052c250f8e (12 bytes) 17:23:41.433 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 15 └─[ConfigurationCCGet] parameter #: 44 17:23:41.433 CNTRLR « [Node 029] received protection status: local: Unprotected 17:23:41.434 CNTRLR [Node 029] [~] [Protection] interviewComplete: true => [Endpoint 1] [internal] true 17:23:41.506 SERIAL « [ACK] (0x06) 17:23:41.512 SERIAL « 0x0104011301e8 (6 bytes) 17:23:41.513 SERIAL » [ACK] (0x06) 17:23:41.515 DRIVER « [RES] [SendData] was sent: true 17:23:41.520 SERIAL « 0x010700130f000009ed (9 bytes) 17:23:41.520 SERIAL » [ACK] (0x06) 17:23:41.522 CNTRLR [Node 029] BatteryCC: doing a partial interview... [Endpoint 1] 17:23:41.522 CNTRLR » [Node 029] querying battery status... [Endpoint 1] 17:23:41.526 DRIVER « [REQ] [SendData] callback id: 15 transmit status: OK 17:23:41.533 SERIAL « 0x010c000400180670062c020258eb (14 bytes) 17:23:41.538 CNTRLR [Node 024] [~] [Configuration] 44: 600 => 600 17:23:41.539 SERIAL » [ACK] (0x06) 17:23:41.540 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 44 value size: 2 value: 600 17:23:41.543 SERIAL » 0x010f00131c08600d000231040100251099 (17 bytes) 17:23:41.544 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 17:23:41.544 CNTRLR « [Node 024] parameter #44 has value: 600 17:23:41.544 CNTRLR » [Node 024] querying parameter #50 value... 17:23:41.548 SERIAL « [ACK] (0x06) 17:23:41.552 SERIAL « 0x0104011301e8 (6 bytes) 17:23:41.552 SERIAL » [ACK] (0x06) 17:23:41.553 DRIVER « [RES] [SendData] was sent: true 17:23:42.913 SERIAL « 0x010700131000008972 (9 bytes) 17:23:42.914 SERIAL » [ACK] (0x06) 17:23:42.915 DRIVER « [REQ] [SendData] callback id: 16 transmit status: OK 17:23:42.953 SERIAL « 0x010c0004000306310504220819f1 (14 bytes) 17:23:42.954 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:23:42.956 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 169.7 => 207.3 [Endpoint 0] 17:23:42.957 SERIAL » [ACK] (0x06) 17:23:42.959 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 207.3 17:23:43.036 SERIAL « 0x01100004001c0a600d02003105012200b83d (18 bytes) 17:23:43.037 CNTRLR [Node 028] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 17:23:43.038 CNTRLR [Node 028] [~] [Multilevel Sensor] Air temperature: 18.3 => 18.4 [Endpoint 2] 17:23:43.039 SERIAL » [ACK] (0x06) 17:23:43.041 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.4 17:23:43.046 SERIAL » 0x010d00131d06600d00018002251120 (15 bytes) 17:23:43.047 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 17 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BatteryCCGet] 17:23:43.048 CNTRLR « [Node 028] received current Air temperature sensor reading: 18.4 [Endpoint 2] °C 17:23:43.048 CNTRLR [Node 028] [~] [Multilevel Sensor] interviewComplete: [Endpoint 2] [internal] true => true 17:23:43.096 SERIAL « [ACK] (0x06) 17:23:43.097 SERIAL « 0x0104011301e8 (6 bytes) 17:23:43.097 SERIAL » [ACK] (0x06) 17:23:43.098 DRIVER « [RES] [SendData] was sent: true 17:23:43.106 CNTRLR [Node 028] NotificationCC: doing a partial interview... [Endpoint 2] 17:23:43.107 CNTRLR [Node 028] [~] [Notification] interviewComplete: true [Endpoint 2] [internal] => true 17:23:43.108 CNTRLR [Node 028] BatteryCC: doing a partial interview... [Endpoint 2] 17:23:43.108 CNTRLR » [Node 028] querying battery status... [Endpoint 2] 17:23:44.541 SERIAL « 0x01070013110000956f (9 bytes) 17:23:44.541 SERIAL » [ACK] (0x06) 17:23:44.542 DRIVER « [REQ] [SendData] callback id: 17 transmit status: OK 17:23:44.656 SERIAL « 0x010d0004001d07600d010080035e5d (15 bytes) 17:23:44.657 CNTRLR [Node 029] [~] [Battery] level: 95 => 94 [Endpoint 1] 17:23:44.658 CNTRLR [Node 029] [~] [Battery] isLow: false => false [Endpoint 1] 17:23:44.658 SERIAL » [ACK] (0x06) 17:23:44.660 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BatteryCCReport] level: 94 is low: false 17:23:44.665 SERIAL » 0x010a0013180370053225128d (12 bytes) 17:23:44.666 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 18 └─[ConfigurationCCGet] parameter #: 50 17:23:44.667 CNTRLR « [Node 029] received response for battery information: [Endpoint 1] level: 94 17:23:44.667 CNTRLR [Node 029] [~] [Battery] interviewComplete: true => tr [Endpoint 1] [internal] ue 17:23:44.719 SERIAL « [ACK] (0x06) 17:23:44.724 SERIAL « 0x0104011301e8 (6 bytes) 17:23:44.725 SERIAL » [ACK] (0x06) 17:23:44.727 DRIVER « [RES] [SendData] was sent: true 17:23:44.731 CNTRLR [Node 029] ClockCC: doing a partial interview... 17:23:44.732 CNTRLR » [Node 029] requesting current clock setting... 17:23:44.773 SERIAL « 0x010700131200000af3 (9 bytes) 17:23:44.773 SERIAL » [ACK] (0x06) 17:23:44.773 DRIVER « [REQ] [SendData] callback id: 18 transmit status: OK 17:23:44.812 SERIAL « 0x010b00040018057006320114bc (13 bytes) 17:23:44.817 CNTRLR [Node 024] [~] [Configuration] 50: 20 => 20 17:23:44.818 SERIAL » [ACK] (0x06) 17:23:44.819 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 20 17:23:44.822 SERIAL » 0x010d00131c06600d00028002251320 (15 bytes) 17:23:44.822 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 19 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[BatteryCCGet] 17:23:44.823 CNTRLR « [Node 024] parameter #50 has value: 20 17:23:44.823 CNTRLR » [Node 024] querying parameter #51 value... 17:23:44.826 SERIAL « [ACK] (0x06) 17:23:44.838 SERIAL « 0x0104011301e8 (6 bytes) 17:23:44.838 SERIAL » [ACK] (0x06) 17:23:44.839 DRIVER « [RES] [SendData] was sent: true 17:23:45.038 SERIAL « 0x010c0004000306310504220a4ea4 (14 bytes) 17:23:45.039 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:23:45.039 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 207.3 => 263.8 [Endpoint 0] 17:23:45.039 SERIAL » [ACK] (0x06) 17:23:45.040 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 263.8 17:23:46.498 SERIAL « 0x01070013130000a75f (9 bytes) 17:23:46.499 SERIAL » [ACK] (0x06) 17:23:46.500 DRIVER « [REQ] [SendData] callback id: 19 transmit status: OK 17:23:46.614 SERIAL « 0x010d0004001c07600d020080036263 (15 bytes) 17:23:46.615 CNTRLR [Node 028] [~] [Battery] level: 98 => 98 [Endpoint 2] 17:23:46.616 CNTRLR [Node 028] [~] [Battery] isLow: false => false [Endpoint 2] 17:23:46.616 SERIAL » [ACK] (0x06) 17:23:46.617 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BatteryCCReport] level: 98 is low: false 17:23:46.621 SERIAL » 0x010d00131d06600d00018105251423 (15 bytes) 17:23:46.621 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 20 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ClockCCGet] 17:23:46.622 CNTRLR « [Node 028] received response for battery information: [Endpoint 2] level: 98 17:23:46.622 CNTRLR [Node 028] [~] [Battery] interviewComplete: true => tr [Endpoint 2] [internal] ue 17:23:46.650 SERIAL « [ACK] (0x06) 17:23:46.651 SERIAL « 0x0104011301e8 (6 bytes) 17:23:46.651 SERIAL » [ACK] (0x06) 17:23:46.655 DRIVER « [RES] [SendData] was sent: true 17:23:46.658 CNTRLR [Node 028] MultilevelSensorCC: doing a partial interview... 17:23:46.658 CNTRLR » [Node 028] querying Air temperature sensor reading... 17:23:46.992 SERIAL « 0x010c000400030631050422089971 (14 bytes) 17:23:46.993 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:23:46.993 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 263.8 => 220.1 [Endpoint 0] 17:23:46.994 SERIAL » [ACK] (0x06) 17:23:46.995 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 220.1 17:23:48.211 SERIAL « 0x010700131400009f60 (9 bytes) 17:23:48.211 SERIAL » [ACK] (0x06) 17:23:48.212 DRIVER « [REQ] [SendData] callback id: 20 transmit status: OK 17:23:48.328 SERIAL « 0x010e0004001d08600d0100810672176e (16 bytes) 17:23:48.329 SERIAL » [ACK] (0x06) 17:23:48.330 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ClockCCReport] clock setting: Wednesday, 18:23 17:23:48.342 SERIAL » 0x010a0013180370053325158b (12 bytes) 17:23:48.343 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 21 └─[ConfigurationCCGet] parameter #: 51 17:23:48.344 CNTRLR « [Node 029] received current clock setting: Wednesday, 18:23 17:23:48.345 CNTRLR [Node 029] [~] [Clock] interviewComplete: true => true [Endpoint 1] [internal] 17:23:48.408 SERIAL « [ACK] (0x06) 17:23:48.410 SERIAL « 0x0104011301e8 (6 bytes) 17:23:48.410 SERIAL » [ACK] (0x06) 17:23:48.411 DRIVER « [RES] [SendData] was sent: true 17:23:48.419 SERIAL « 0x0107001315000008f6 (9 bytes) 17:23:48.420 SERIAL » [ACK] (0x06) 17:23:48.421 DRIVER « [REQ] [SendData] callback id: 21 transmit status: OK 17:23:48.433 SERIAL « 0x010b0004001805700633010aa3 (13 bytes) 17:23:48.439 CNTRLR [Node 024] [~] [Configuration] 51: 10 => 10 17:23:48.440 SERIAL » [ACK] (0x06) 17:23:48.440 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 51 value size: 1 value: 10 17:23:48.443 SERIAL » 0x010b00131c04310401002516f8 (13 bytes) 17:23:48.444 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 22 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 17:23:48.444 CNTRLR « [Node 024] parameter #51 has value: 10 17:23:48.445 CNTRLR » [Node 024] querying parameter #53 value... 17:23:48.447 SERIAL « [ACK] (0x06) 17:23:48.452 SERIAL « 0x0104011301e8 (6 bytes) 17:23:48.453 SERIAL » [ACK] (0x06) 17:23:48.454 DRIVER « [RES] [SendData] was sent: true 17:23:49.001 CNTRLR [Node 029] ZWavePlusCC: doing a partial interview... [Endpoint 2] 17:23:49.001 CNTRLR [Node 029] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 17:23:49.001 CNTRLR [Node 029] MultilevelSensorCC: doing a partial interview... [Endpoint 2] 17:23:49.002 CNTRLR » [Node 029] querying Air temperature sensor reading... [Endpoint 2] 17:23:49.879 SERIAL « 0x010700131600008f72 (9 bytes) 17:23:49.879 SERIAL » [ACK] (0x06) 17:23:49.880 DRIVER « [REQ] [SendData] callback id: 22 transmit status: OK 17:23:49.958 SERIAL « 0x010c000400030631050422074bac (14 bytes) 17:23:49.960 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:23:49.961 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 220.1 => 186.7 [Endpoint 0] 17:23:49.961 SERIAL » [ACK] (0x06) 17:23:49.963 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 186.7 17:23:49.999 SERIAL « 0x010c0004001c063105012200b842 (14 bytes) 17:23:50.000 CNTRLR [Node 028] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 17:23:50.001 CNTRLR [Node 028] [~] [Multilevel Sensor] Air temperature: 19.6 => 18.4 [Endpoint 0] 17:23:50.002 SERIAL » [ACK] (0x06) 17:23:50.003 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.4 17:23:50.009 SERIAL » 0x010a0013180370053525178f (12 bytes) 17:23:50.010 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 23 └─[ConfigurationCCGet] parameter #: 53 17:23:50.011 CNTRLR « [Node 028] received current Air temperature sensor reading: 18.4 °C 17:23:50.012 CNTRLR [Node 028] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 17:23:50.067 SERIAL « [ACK] (0x06) 17:23:50.070 SERIAL « 0x0104011301e8 (6 bytes) 17:23:50.071 SERIAL » [ACK] (0x06) 17:23:50.071 DRIVER « [RES] [SendData] was sent: true 17:23:50.074 CNTRLR [Node 028] ThermostatModeCC: doing a partial interview... 17:23:50.074 CNTRLR » [Node 028] querying current thermostat mode... 17:23:50.099 SERIAL « 0x0107001317000009f5 (9 bytes) 17:23:50.099 SERIAL » [ACK] (0x06) 17:23:50.100 DRIVER « [REQ] [SendData] callback id: 23 transmit status: OK 17:23:50.114 SERIAL « 0x010c0004001806700635020064cc (14 bytes) 17:23:50.119 CNTRLR [Node 024] [~] [Configuration] 53: 100 => 100 17:23:50.120 SERIAL » [ACK] (0x06) 17:23:50.120 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 53 value size: 2 value: 100 17:23:50.123 SERIAL » 0x010f00131d08600d000231040100251890 (17 bytes) 17:23:50.124 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 24 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 17:23:50.124 CNTRLR « [Node 024] parameter #53 has value: 100 17:23:50.124 CNTRLR » [Node 024] querying parameter #54 value... 17:23:50.128 SERIAL « [ACK] (0x06) 17:23:50.133 SERIAL « 0x0104011301e8 (6 bytes) 17:23:50.133 SERIAL » [ACK] (0x06) 17:23:50.134 DRIVER « [RES] [SendData] was sent: true 17:23:51.638 SERIAL « 0x010700131800009764 (9 bytes) 17:23:51.639 SERIAL » [ACK] (0x06) 17:23:51.639 DRIVER « [REQ] [SendData] callback id: 24 transmit status: OK 17:23:51.762 SERIAL « 0x01100004001d0a600d02003105012200ad29 (18 bytes) 17:23:51.764 CNTRLR [Node 029] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 17:23:51.765 CNTRLR [Node 029] [~] [Multilevel Sensor] Air temperature: 17.2 => 17.3 [Endpoint 2] 17:23:51.765 SERIAL » [ACK] (0x06) 17:23:51.767 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 17.3 17:23:51.772 SERIAL » 0x010900131c024002251985 (11 bytes) 17:23:51.772 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 25 └─[ThermostatModeCCGet] 17:23:51.773 CNTRLR « [Node 029] received current Air temperature sensor reading: 17.3 [Endpoint 2] °C 17:23:51.774 CNTRLR [Node 029] [~] [Multilevel Sensor] interviewComplete: [Endpoint 2] [internal] true => true 17:23:51.824 SERIAL « [ACK] (0x06) 17:23:51.829 SERIAL « 0x0104011301e8 (6 bytes) 17:23:51.829 SERIAL » [ACK] (0x06) 17:23:51.831 DRIVER « [RES] [SendData] was sent: true 17:23:51.833 CNTRLR [Node 029] NotificationCC: doing a partial interview... [Endpoint 2] 17:23:51.833 CNTRLR » [Node 029] querying notification status for Power Management... [Endpoint 2] 17:23:53.209 SERIAL « 0x010700131900008f7d (9 bytes) 17:23:53.210 SERIAL » [ACK] (0x06) 17:23:53.211 DRIVER « [REQ] [SendData] callback id: 25 transmit status: OK 17:23:53.321 SERIAL « 0x01090004001c03400301af (11 bytes) 17:23:53.323 CNTRLR [Node 028] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 0] 17:23:53.324 SERIAL » [ACK] (0x06) 17:23:53.325 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ThermostatModeCCReport] mode: Heat 17:23:53.331 SERIAL » 0x010a00131803700536251a81 (12 bytes) 17:23:53.332 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 26 └─[ConfigurationCCGet] parameter #: 54 17:23:53.333 CNTRLR « [Node 028] received current thermostat mode: Heat 17:23:53.333 CNTRLR [Node 028] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 0] [internal] ue => true 17:23:53.396 SERIAL « [ACK] (0x06) 17:23:53.403 SERIAL « 0x0104011301e8 (6 bytes) 17:23:53.403 SERIAL » [ACK] (0x06) 17:23:53.405 DRIVER « [RES] [SendData] was sent: true 17:23:53.408 CNTRLR [Node 028] ThermostatSetpointCC: doing a partial interview... 17:23:53.408 CNTRLR » [Node 028] querying current value of setpoint Heating... 17:23:53.422 SERIAL « 0x010700131a000009f8 (9 bytes) 17:23:53.422 SERIAL » [ACK] (0x06) 17:23:53.422 DRIVER « [REQ] [SendData] callback id: 26 transmit status: OK 17:23:53.433 SERIAL « 0x010b00040018057006360114b8 (13 bytes) 17:23:53.438 CNTRLR [Node 024] [~] [Configuration] 54: 20 => 20 17:23:53.439 SERIAL » [ACK] (0x06) 17:23:53.440 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 54 value size: 1 value: 20 17:23:53.443 SERIAL » 0x011000131d09600d00027104000800251bc4 (18 bytes) 17:23:53.443 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 27 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: Power Management 17:23:53.444 CNTRLR « [Node 024] parameter #54 has value: 20 17:23:53.444 CNTRLR » [Node 024] querying parameter #55 value... 17:23:53.447 SERIAL « [ACK] (0x06) 17:23:53.452 SERIAL « 0x0104011301e8 (6 bytes) 17:23:53.452 SERIAL » [ACK] (0x06) 17:23:53.453 DRIVER « [RES] [SendData] was sent: true 17:23:53.625 SERIAL « 0x01090004001b03200100cb (11 bytes) 17:23:53.626 SERIAL » [ACK] (0x06) 17:23:53.627 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:23:53.628 CNTRLR [Node 027] treating BasicCC Set as a report 17:23:53.629 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:23:53.773 SERIAL « 0x010d0004001b079c021b00ff000090 (15 bytes) 17:23:53.775 CNTRLR [Node 027] [~] [Alarm Sensor] state[0]: false => true [Endpoint 0] 17:23:53.776 CNTRLR [Node 027] [+] [Alarm Sensor] severity[0]: undefined [Endpoint 0] 17:23:53.777 CNTRLR [Node 027] [+] [Alarm Sensor] duration[0]: undefined [Endpoint 0] 17:23:53.777 SERIAL » [ACK] (0x06) 17:23:53.779 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: true 17:23:53.794 SERIAL « 0x010d0004001b079c021b00ff000090 (15 bytes) 17:23:53.795 CNTRLR [Node 027] [~] [Alarm Sensor] state[0]: true => true [Endpoint 0] 17:23:53.795 CNTRLR [Node 027] [~] [Alarm Sensor] severity[0]: undefined => undefined [Endpoint 0] 17:23:53.796 CNTRLR [Node 027] [~] [Alarm Sensor] duration[0]: undefined => undefined [Endpoint 0] 17:23:53.796 SERIAL » [ACK] (0x06) 17:23:53.797 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: true 17:23:55.012 SERIAL « 0x010700131b00009d6d (9 bytes) 17:23:55.012 SERIAL » [ACK] (0x06) 17:23:55.013 DRIVER « [REQ] [SendData] callback id: 27 transmit status: OK 17:23:55.097 SERIAL « 0x01130004001d0d600d02007105000000ff08fe00ea (21 bytes) 17:23:55.098 SERIAL » [ACK] (0x06) 17:23:55.099 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 17:23:55.103 SERIAL » 0x010a00131c03430201251c80 (12 bytes) 17:23:55.104 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 28 └─[ThermostatSetpointCCGet] setpoint type: Heating 17:23:55.105 CNTRLR [Node 029] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 2] 54 17:23:55.106 CNTRLR » [Node 029] querying notification status for System... [Endpoint 2] 17:23:55.110 SERIAL « [ACK] (0x06) 17:23:55.112 SERIAL « 0x0104011301e8 (6 bytes) 17:23:55.113 SERIAL » [ACK] (0x06) 17:23:55.113 DRIVER « [RES] [SendData] was sent: true 17:23:57.730 SERIAL « 0x010700131c000107f1 (9 bytes) 17:23:57.730 SERIAL » [ACK] (0x06) 17:23:57.731 DRIVER « [REQ] [SendData] callback id: 28 transmit status: OK 17:23:59.333 CNTRLR [Node 028] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 17:23:59.840 SERIAL » 0x010a00131c03430201251c80 (12 bytes) 17:23:59.841 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 28 └─[ThermostatSetpointCCGet] setpoint type: Heating 17:23:59.844 SERIAL « [ACK] (0x06) 17:23:59.850 SERIAL « 0x0104011301e8 (6 bytes) 17:23:59.851 SERIAL » [ACK] (0x06) 17:23:59.852 DRIVER « [RES] [SendData] was sent: true 17:23:59.907 SERIAL « 0x010700131c000006f1 (9 bytes) 17:23:59.907 SERIAL » [ACK] (0x06) 17:23:59.908 DRIVER « [REQ] [SendData] callback id: 28 transmit status: OK 17:23:59.987 SERIAL « 0x010c0004001c06430301220064ea (14 bytes) 17:23:59.988 CNTRLR [Node 028] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 0] 17:23:59.989 CNTRLR [Node 028] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 17:23:59.989 SERIAL » [ACK] (0x06) 17:23:59.989 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 17:23:59.992 SERIAL » 0x010a00131803700537251d87 (12 bytes) 17:23:59.993 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 29 └─[ConfigurationCCGet] parameter #: 55 17:23:59.993 CNTRLR « [Node 028] received current value of setpoint Heating: 10 °C 17:23:59.993 CNTRLR [Node 028] [~] [Thermostat Setpoint] interviewComplete [Endpoint 0] [internal] : true => true 17:24:00.019 SERIAL « [ACK] (0x06) 17:24:00.020 SERIAL « 0x0104011301e8 (6 bytes) 17:24:00.020 SERIAL » [ACK] (0x06) 17:24:00.024 DRIVER « [RES] [SendData] was sent: true 17:24:00.026 CNTRLR [Node 028] ConfigurationCC: Loading configuration parameters from device confi g 17:24:00.031 CNTRLR [Node 028] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:24:00.032 CNTRLR [Node 028] [Configuration] 1: metadata updated 17:24:00.033 CNTRLR [Node 028] [Configuration] 2: metadata updated 17:24:00.034 CNTRLR [Node 028] [Configuration] 3: metadata updated 17:24:00.035 CNTRLR [Node 028] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:24:00.035 CNTRLR » [Node 028] querying parameter #1 value... 17:24:00.039 SERIAL « 0x010700131d000005f3 (9 bytes) 17:24:00.040 SERIAL » [ACK] (0x06) 17:24:00.041 DRIVER « [REQ] [SendData] callback id: 29 transmit status: OK 17:24:00.053 SERIAL « 0x010b0004001805700637010aa7 (13 bytes) 17:24:00.058 CNTRLR [Node 024] [~] [Configuration] 55: 10 => 10 17:24:00.059 SERIAL » [ACK] (0x06) 17:24:00.060 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 55 value size: 1 value: 10 17:24:00.063 SERIAL » 0x011000131d09600d00027104000900251ec0 (18 bytes) 17:24:00.063 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 30 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 17:24:00.064 CNTRLR « [Node 024] parameter #55 has value: 10 17:24:00.064 CNTRLR » [Node 024] querying parameter #57 value... 17:24:00.066 SERIAL « [ACK] (0x06) 17:24:00.071 SERIAL « 0x0104011301e8 (6 bytes) 17:24:00.072 SERIAL » [ACK] (0x06) 17:24:00.072 DRIVER « [RES] [SendData] was sent: true 17:24:01.527 SERIAL « 0x010700131e00009267 (9 bytes) 17:24:01.528 SERIAL » [ACK] (0x06) 17:24:01.529 DRIVER « [REQ] [SendData] callback id: 30 transmit status: OK 17:24:03.133 CNTRLR [Node 029] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 17:24:03.637 SERIAL » 0x011000131d09600d00027104000900251ec0 (18 bytes) 17:24:03.638 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 30 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 17:24:03.641 SERIAL « [ACK] (0x06) 17:24:03.647 SERIAL « 0x0104011301e8 (6 bytes) 17:24:03.648 SERIAL » [ACK] (0x06) 17:24:03.649 DRIVER « [RES] [SendData] was sent: true 17:24:05.155 SERIAL « 0x010700131e00009762 (9 bytes) 17:24:05.155 SERIAL » [ACK] (0x06) 17:24:05.156 DRIVER « [REQ] [SendData] callback id: 30 transmit status: OK 17:24:06.610 SERIAL « 0x01100004001c0a600d02003105012200bc39 (18 bytes) 17:24:06.612 CNTRLR [Node 028] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 17:24:06.613 CNTRLR [Node 028] [~] [Multilevel Sensor] Air temperature: 18.4 => 18.8 [Endpoint 2] 17:24:06.614 SERIAL » [ACK] (0x06) 17:24:06.616 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.8 17:24:06.759 CNTRLR [Node 029] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 17:24:07.262 SERIAL » 0x011000131d09600d00027104000900251ec0 (18 bytes) 17:24:07.262 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 30 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 17:24:07.264 SERIAL « [ACK] (0x06) 17:24:07.271 SERIAL « 0x0104011301e8 (6 bytes) 17:24:07.271 SERIAL » [ACK] (0x06) 17:24:07.271 DRIVER « [RES] [SendData] was sent: true 17:24:08.743 SERIAL « 0x010700131e00009461 (9 bytes) 17:24:08.744 SERIAL » [ACK] (0x06) 17:24:08.744 DRIVER « [REQ] [SendData] callback id: 30 transmit status: OK 17:24:10.351 SERIAL » 0x010a00131c03700501251fb7 (12 bytes) 17:24:10.353 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 31 └─[ConfigurationCCGet] parameter #: 1 17:24:10.354 CNTRLR [Node 029] querying notification status for System timed out - sk [Endpoint 2] ipping because it is not critical... 17:24:10.355 CNTRLR [Node 029] [~] [Notification] interviewComplete: true [Endpoint 2] [internal] => true 17:24:10.426 SERIAL « [ACK] (0x06) 17:24:10.428 SERIAL « 0x0104011301e8 (6 bytes) 17:24:10.429 SERIAL » [ACK] (0x06) 17:24:10.430 DRIVER « [RES] [SendData] was sent: true 17:24:10.492 CNTRLR [Node 029] BatteryCC: doing a partial interview... [Endpoint 2] 17:24:10.492 CNTRLR » [Node 029] querying battery status... [Endpoint 2] 17:24:11.751 SERIAL « 0x010700131f00008c78 (9 bytes) 17:24:11.752 SERIAL » [ACK] (0x06) 17:24:11.753 DRIVER « [REQ] [SendData] callback id: 31 transmit status: OK 17:24:11.882 SERIAL « 0x010e0004001c08700601040000003cae (16 bytes) 17:24:11.895 CNTRLR [Node 028] [~] [Configuration] 1: 60 => 60 17:24:11.896 SERIAL » [ACK] (0x06) 17:24:11.898 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 4 value: 60 17:24:11.905 SERIAL » 0x010a001318037005392520b4 (12 bytes) 17:24:11.905 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 32 └─[ConfigurationCCGet] parameter #: 57 17:24:11.906 CNTRLR « [Node 028] parameter #1 has value: 60 17:24:11.907 CNTRLR » [Node 028] querying parameter #2 value... 17:24:11.913 SERIAL « [ACK] (0x06) 17:24:11.916 SERIAL « 0x0104011301e8 (6 bytes) 17:24:11.917 SERIAL » [ACK] (0x06) 17:24:11.918 DRIVER « [RES] [SendData] was sent: true 17:24:11.969 SERIAL « 0x0107001320000006cd (9 bytes) 17:24:11.970 SERIAL » [ACK] (0x06) 17:24:11.971 DRIVER « [REQ] [SendData] callback id: 32 transmit status: OK 17:24:11.983 SERIAL « 0x010c0004001806700639020064c0 (14 bytes) 17:24:11.989 CNTRLR [Node 024] [~] [Configuration] 57: 100 => 100 17:24:11.990 SERIAL » [ACK] (0x06) 17:24:11.991 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 57 value size: 2 value: 100 17:24:11.996 SERIAL » 0x010d00131d06600d00028002252113 (15 bytes) 17:24:11.996 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 33 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[BatteryCCGet] 17:24:11.997 CNTRLR « [Node 024] parameter #57 has value: 100 17:24:11.997 CNTRLR » [Node 024] querying parameter #58 value... 17:24:12.005 SERIAL « [ACK] (0x06) 17:24:12.006 SERIAL « 0x0104011301e8 (6 bytes) 17:24:12.006 SERIAL » [ACK] (0x06) 17:24:12.008 DRIVER « [RES] [SendData] was sent: true 17:24:13.491 SERIAL « 0x01070013210000955f (9 bytes) 17:24:13.492 SERIAL » [ACK] (0x06) 17:24:13.493 DRIVER « [REQ] [SendData] callback id: 33 transmit status: OK 17:24:13.607 SERIAL « 0x010d0004001d07600d020080035e5e (15 bytes) 17:24:13.609 CNTRLR [Node 029] [~] [Battery] level: 95 => 94 [Endpoint 2] 17:24:13.610 CNTRLR [Node 029] [~] [Battery] isLow: false => false [Endpoint 2] 17:24:13.610 SERIAL » [ACK] (0x06) 17:24:13.613 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BatteryCCReport] level: 94 is low: false 17:24:13.622 SERIAL » 0x010a00131c03700502252289 (12 bytes) 17:24:13.623 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 34 └─[ConfigurationCCGet] parameter #: 2 17:24:13.624 CNTRLR « [Node 029] received response for battery information: [Endpoint 2] level: 94 17:24:13.625 CNTRLR [Node 029] [~] [Battery] interviewComplete: true => tr [Endpoint 2] [internal] ue 17:24:13.712 SERIAL « [ACK] (0x06) 17:24:13.714 SERIAL « 0x0104011301e8 (6 bytes) 17:24:13.715 SERIAL » [ACK] (0x06) 17:24:13.716 DRIVER « [RES] [SendData] was sent: true 17:24:13.719 CNTRLR [Node 029] MultilevelSensorCC: doing a partial interview... 17:24:13.719 CNTRLR » [Node 029] querying Air temperature sensor reading... 17:24:14.559 SERIAL « 0x01090004000b0380034b32 (11 bytes) 17:24:14.560 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 17:24:14.561 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 17:24:14.562 SERIAL » [ACK] (0x06) 17:24:14.563 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 17:24:15.124 SERIAL « 0x010c0004000b064303014203e812 (14 bytes) 17:24:15.125 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 0] 17:24:15.125 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 17:24:15.126 SERIAL » [ACK] (0x06) 17:24:15.128 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 17:24:15.136 SERIAL « 0x01070013220000975e (9 bytes) 17:24:15.137 SERIAL » [ACK] (0x06) 17:24:15.137 DRIVER « [REQ] [SendData] callback id: 34 transmit status: OK 17:24:15.192 SERIAL « 0x010a0004000b044608007fcf (12 bytes) 17:24:15.194 CNTRLR [Node 011] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 17:24:15.194 CNTRLR [Node 011] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 17:24:15.195 SERIAL » [ACK] (0x06) 17:24:15.196 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ClimateControlScheduleCCOverrideReport] override type: None override state: Unused 17:24:15.247 SERIAL « 0x01080004000b02840779 (10 bytes) 17:24:15.248 SERIAL » [ACK] (0x06) 17:24:15.248 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:24:15.249 CNTRLR « [Node 011] received wakeup notification 17:24:15.250 CNTRLR [Node 011] The node is now awake. 17:24:15.251 CNTRLR [Node 011] expects some queries after wake up, so it shall receive 17:24:15.251 CNTRLR [Node 011] compat query "Battery"::get() 17:24:16.740 CNTRLR [Node 028] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 17:24:17.243 SERIAL » 0x010a00131c03700502252289 (12 bytes) 17:24:17.244 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 34 └─[ConfigurationCCGet] parameter #: 2 17:24:17.245 SERIAL « [ACK] (0x06) 17:24:17.252 SERIAL « 0x0104011301e8 (6 bytes) 17:24:17.252 SERIAL » [ACK] (0x06) 17:24:17.253 DRIVER « [RES] [SendData] was sent: true 17:24:17.308 SERIAL « 0x0107001322000006cf (9 bytes) 17:24:17.308 SERIAL » [ACK] (0x06) 17:24:17.309 DRIVER « [REQ] [SendData] callback id: 34 transmit status: OK 17:24:17.390 SERIAL « 0x010e0004001c08700602040000000190 (16 bytes) 17:24:17.395 CNTRLR [Node 028] [~] [Configuration] 2: 1 => 1 17:24:17.396 SERIAL » [ACK] (0x06) 17:24:17.398 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 4 value: 1 17:24:17.401 SERIAL » 0x010a0013180370053a2523b4 (12 bytes) 17:24:17.402 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 35 └─[ConfigurationCCGet] parameter #: 58 17:24:17.402 CNTRLR « [Node 028] parameter #2 has value: 1 17:24:17.402 CNTRLR » [Node 028] querying parameter #3 value... 17:24:17.405 SERIAL « [ACK] (0x06) 17:24:17.410 SERIAL « 0x0104011301e8 (6 bytes) 17:24:17.410 SERIAL » [ACK] (0x06) 17:24:17.411 DRIVER « [RES] [SendData] was sent: true 17:24:17.489 SERIAL « 0x0107001323000009c1 (9 bytes) 17:24:17.489 SERIAL » [ACK] (0x06) 17:24:17.489 DRIVER « [REQ] [SendData] callback id: 35 transmit status: OK 17:24:17.504 SERIAL « 0x010c000400180670063a020e10b9 (14 bytes) 17:24:17.509 CNTRLR [Node 024] [~] [Configuration] 58: 3600 => 3600 17:24:17.510 SERIAL » [ACK] (0x06) 17:24:17.511 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 58 value size: 2 value: 3600 17:24:17.514 SERIAL » 0x010b00131d04310401002524cb (13 bytes) 17:24:17.514 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 36 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 17:24:17.514 CNTRLR « [Node 024] parameter #58 has value: 3600 17:24:17.517 CNTRLR » [Node 024] querying parameter #59 value... 17:24:17.524 SERIAL « [ACK] (0x06) 17:24:17.525 SERIAL « 0x0104011301e8 (6 bytes) 17:24:17.526 SERIAL » [ACK] (0x06) 17:24:17.535 DRIVER « [RES] [SendData] was sent: true 17:24:18.970 SERIAL « 0x01070013240000925d (9 bytes) 17:24:18.970 SERIAL » [ACK] (0x06) 17:24:18.971 DRIVER « [REQ] [SendData] callback id: 36 transmit status: OK 17:24:19.089 SERIAL « 0x010c0004001d063105012200ad56 (14 bytes) 17:24:19.091 CNTRLR [Node 029] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 17:24:19.092 CNTRLR [Node 029] [~] [Multilevel Sensor] Air temperature: 19.1 => 17.3 [Endpoint 0] 17:24:19.092 SERIAL » [ACK] (0x06) 17:24:19.094 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 17.3 17:24:19.100 SERIAL » 0x010a00131c0370050325258f (12 bytes) 17:24:19.101 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 37 └─[ConfigurationCCGet] parameter #: 3 17:24:19.101 CNTRLR « [Node 029] received current Air temperature sensor reading: 17.3 °C 17:24:19.102 CNTRLR [Node 029] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 17:24:19.173 SERIAL « [ACK] (0x06) 17:24:19.182 SERIAL « 0x0104011301e8 (6 bytes) 17:24:19.183 SERIAL » [ACK] (0x06) 17:24:19.186 DRIVER « [RES] [SendData] was sent: true 17:24:19.188 CNTRLR [Node 029] ThermostatModeCC: doing a partial interview... 17:24:19.189 CNTRLR » [Node 029] querying current thermostat mode... 17:24:20.541 SERIAL « 0x01070013250000905e (9 bytes) 17:24:20.541 SERIAL » [ACK] (0x06) 17:24:20.542 DRIVER « [REQ] [SendData] callback id: 37 transmit status: OK 17:24:20.664 SERIAL « 0x010e0004001c08700603040000000090 (16 bytes) 17:24:20.673 CNTRLR [Node 028] [~] [Configuration] 3: 0 => 0 17:24:20.675 SERIAL » [ACK] (0x06) 17:24:20.676 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 4 value: 0 17:24:20.681 SERIAL » 0x010a0013180370053b2526b0 (12 bytes) 17:24:20.684 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 38 └─[ConfigurationCCGet] parameter #: 59 17:24:20.685 CNTRLR « [Node 028] parameter #3 has value: 0 17:24:20.686 CNTRLR [Node 028] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:24:20.741 SERIAL « [ACK] (0x06) 17:24:20.745 SERIAL « 0x0104011301e8 (6 bytes) 17:24:20.746 SERIAL » [ACK] (0x06) 17:24:20.747 DRIVER « [RES] [SendData] was sent: true 17:24:20.749 CNTRLR [Node 028] ProtectionCC: doing a partial interview... 17:24:20.749 CNTRLR » [Node 028] querying protection status... 17:24:20.759 SERIAL « 0x0107001326000008c5 (9 bytes) 17:24:20.759 SERIAL » [ACK] (0x06) 17:24:20.759 DRIVER « [REQ] [SendData] callback id: 38 transmit status: OK 17:24:20.773 SERIAL « 0x010c000400180670063b020e10b8 (14 bytes) 17:24:20.778 CNTRLR [Node 024] [~] [Configuration] 59: 3600 => 3600 17:24:20.779 SERIAL » [ACK] (0x06) 17:24:20.780 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 59 value size: 2 value: 3600 17:24:20.783 SERIAL » 0x010900131d0240022527ba (11 bytes) 17:24:20.783 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[ThermostatModeCCGet] 17:24:20.784 CNTRLR « [Node 024] parameter #59 has value: 3600 17:24:20.784 CNTRLR » [Node 024] querying parameter #60 value... 17:24:20.787 SERIAL « [ACK] (0x06) 17:24:20.791 SERIAL « 0x0104011301e8 (6 bytes) 17:24:20.791 SERIAL » [ACK] (0x06) 17:24:20.792 DRIVER « [RES] [SendData] was sent: true 17:24:22.269 SERIAL « 0x010700132700009559 (9 bytes) 17:24:22.270 SERIAL » [ACK] (0x06) 17:24:22.270 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 17:24:22.382 SERIAL « 0x01090004001d03400301ae (11 bytes) 17:24:22.382 CNTRLR [Node 029] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 0] 17:24:22.383 SERIAL » [ACK] (0x06) 17:24:22.384 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ThermostatModeCCReport] mode: Heat 17:24:22.387 SERIAL » 0x010900131c027502252881 (11 bytes) 17:24:22.388 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 40 └─[ProtectionCCGet] 17:24:22.388 CNTRLR « [Node 029] received current thermostat mode: Heat 17:24:22.389 CNTRLR [Node 029] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 0] [internal] ue => true 17:24:22.419 SERIAL « [ACK] (0x06) 17:24:22.422 SERIAL « 0x0104011301e8 (6 bytes) 17:24:22.422 SERIAL » [ACK] (0x06) 17:24:22.423 DRIVER « [RES] [SendData] was sent: true 17:24:22.426 CNTRLR [Node 029] ThermostatSetpointCC: doing a partial interview... 17:24:22.426 CNTRLR » [Node 029] querying current value of setpoint Heating... 17:24:23.864 SERIAL « 0x010700132800009350 (9 bytes) 17:24:23.865 SERIAL » [ACK] (0x06) 17:24:23.865 DRIVER « [REQ] [SendData] callback id: 40 transmit status: OK 17:24:23.977 SERIAL « 0x01090004001c037503009b (11 bytes) 17:24:23.978 CNTRLR [Node 028] [~] [Protection] local: 0 => 0 [Endpoint 0] 17:24:23.979 SERIAL » [ACK] (0x06) 17:24:23.980 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected 17:24:23.987 SERIAL » 0x010a0013180370053c2529b8 (12 bytes) 17:24:23.988 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 41 └─[ConfigurationCCGet] parameter #: 60 17:24:23.988 CNTRLR « [Node 028] received protection status: local: Unprotected 17:24:23.989 CNTRLR [Node 028] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 17:24:24.048 SERIAL « [ACK] (0x06) 17:24:24.053 SERIAL « 0x0104011301e8 (6 bytes) 17:24:24.054 SERIAL » [ACK] (0x06) 17:24:24.054 DRIVER « [RES] [SendData] was sent: true 17:24:24.059 CNTRLR [Node 028] ClockCC: doing a partial interview... 17:24:24.059 CNTRLR » [Node 028] requesting current clock setting... 17:24:24.069 SERIAL « 0x0107001329000008ca (9 bytes) 17:24:24.070 SERIAL » [ACK] (0x06) 17:24:24.071 DRIVER « [REQ] [SendData] callback id: 41 transmit status: OK 17:24:24.083 SERIAL « 0x010b000400180570063c0100a6 (13 bytes) 17:24:24.094 CNTRLR [Node 024] [~] [Configuration] 60: 0 => 0 17:24:24.095 SERIAL » [ACK] (0x06) 17:24:24.097 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 1 value: 0 17:24:24.100 SERIAL » 0x010a00131d03430201252ab7 (12 bytes) 17:24:24.101 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 42 └─[ThermostatSetpointCCGet] setpoint type: Heating 17:24:24.101 CNTRLR « [Node 024] parameter #60 has value: 0 17:24:24.101 CNTRLR [Node 024] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:24:24.102 CNTRLR [Node 024] ProtectionCC: doing a partial interview... 17:24:24.102 CNTRLR » [Node 024] querying protection status... 17:24:24.105 SERIAL « [ACK] (0x06) 17:24:24.109 SERIAL « 0x0104011301e8 (6 bytes) 17:24:24.109 SERIAL » [ACK] (0x06) 17:24:24.111 DRIVER « [RES] [SendData] was sent: true 17:24:25.251 DRIVER The awake timeout for node 11 has elapsed. Assuming it is asleep. 17:24:25.257 CNTRLR [Node 011] The node is now asleep. 17:24:25.261 CNTRLR [Node 011] error during API call: ZWaveError: The node is asleep 17:24:25.261 CNTRLR [Node 011] compat query "Thermostat Setpoint"::get(1) 17:24:25.537 SERIAL « 0x010700132a00008f4e (9 bytes) 17:24:25.538 SERIAL » [ACK] (0x06) 17:24:25.539 DRIVER « [REQ] [SendData] callback id: 42 transmit status: OK 17:24:25.656 SERIAL « 0x010c0004001d06430301220064eb (14 bytes) 17:24:25.658 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 0] 17:24:25.658 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 17:24:25.659 SERIAL » [ACK] (0x06) 17:24:25.660 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 17:24:25.667 SERIAL » 0x010900131c028105252b71 (11 bytes) 17:24:25.668 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 43 └─[ClockCCGet] 17:24:25.668 CNTRLR « [Node 029] received current value of setpoint Heating: 10 °C 17:24:25.669 CNTRLR [Node 029] [~] [Thermostat Setpoint] interviewComplete [Endpoint 0] [internal] : true => true 17:24:25.742 SERIAL « [ACK] (0x06) 17:24:25.749 SERIAL « 0x0104011301e8 (6 bytes) 17:24:25.749 SERIAL » [ACK] (0x06) 17:24:25.751 DRIVER « [RES] [SendData] was sent: true 17:24:25.754 CNTRLR [Node 029] ConfigurationCC: Loading configuration parameters from device confi g 17:24:25.762 CNTRLR [Node 029] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:24:25.763 CNTRLR [Node 029] [Configuration] 1: metadata updated 17:24:25.765 CNTRLR [Node 029] [Configuration] 2: metadata updated 17:24:25.767 CNTRLR [Node 029] [Configuration] 3: metadata updated 17:24:25.768 CNTRLR [Node 029] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:24:25.768 CNTRLR » [Node 029] querying parameter #1 value... 17:24:27.129 SERIAL « 0x0114000400220e600d0100320221440000027200008a (22 bytes) 17:24:27.130 CNTRLR [Node 034] [~] [Meter] value[65537]: 6.26 => 6.26 [Endpoint 1] 17:24:27.131 CNTRLR [Node 034] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 1] 17:24:27.132 SERIAL » [ACK] (0x06) 17:24:27.133 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 6.26 time delta: 0 seconds 17:24:27.170 SERIAL « 0x010700132b00009656 (9 bytes) 17:24:27.170 SERIAL » [ACK] (0x06) 17:24:27.171 DRIVER « [REQ] [SendData] callback id: 43 transmit status: OK 17:24:27.220 SERIAL « 0x0114000400220e600d0200320221440000009300006a (22 bytes) 17:24:27.221 CNTRLR [Node 034] [~] [Meter] value[65537]: 1.47 => 1.47 [Endpoint 2] 17:24:27.222 CNTRLR [Node 034] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 2] 17:24:27.223 SERIAL » [ACK] (0x06) 17:24:27.224 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 1.47 time delta: 0 seconds 17:24:28.774 CNTRLR [Node 028] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 17:24:29.278 SERIAL » 0x010900131c028105252b71 (11 bytes) 17:24:29.278 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 43 └─[ClockCCGet] 17:24:29.280 SERIAL « [ACK] (0x06) 17:24:29.286 SERIAL « 0x0104011301e8 (6 bytes) 17:24:29.287 SERIAL » [ACK] (0x06) 17:24:29.287 DRIVER « [RES] [SendData] was sent: true 17:24:29.542 SERIAL « 0x01100004001d0a600d02003105012200b135 (18 bytes) 17:24:29.543 CNTRLR [Node 029] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 17:24:29.543 CNTRLR [Node 029] [~] [Multilevel Sensor] Air temperature: 17.3 => 17.7 [Endpoint 2] 17:24:29.544 SERIAL » [ACK] (0x06) 17:24:29.545 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 17.7 17:24:30.757 SERIAL « 0x0112000400220c600d020032022132000000008b (20 bytes) 17:24:30.758 CNTRLR [Node 034] [~] [Meter] value[66049]: 0 => 0 [Endpoint 2] 17:24:30.760 CNTRLR [Node 034] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 2] 17:24:30.760 SERIAL » [ACK] (0x06) 17:24:30.763 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 17:24:30.797 SERIAL « 0x010700132b00009757 (9 bytes) 17:24:30.797 SERIAL » [ACK] (0x06) 17:24:30.798 DRIVER « [REQ] [SendData] callback id: 43 transmit status: OK 17:24:30.874 SERIAL « 0x01100004001d0a600d02003105012200b135 (18 bytes) 17:24:30.875 CNTRLR [Node 029] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 17:24:30.876 CNTRLR [Node 029] [~] [Multilevel Sensor] Air temperature: 17.7 => 17.7 [Endpoint 2] 17:24:30.877 SERIAL » [ACK] (0x06) 17:24:30.878 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 17.7 17:24:32.402 CNTRLR [Node 028] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 17:24:32.908 SERIAL » 0x010900131c028105252b71 (11 bytes) 17:24:32.909 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 43 └─[ClockCCGet] 17:24:32.911 SERIAL « [ACK] (0x06) 17:24:32.917 SERIAL « 0x0104011301e8 (6 bytes) 17:24:32.918 SERIAL » [ACK] (0x06) 17:24:32.919 DRIVER « [RES] [SendData] was sent: true 17:24:32.973 SERIAL « 0x010700132b000006c6 (9 bytes) 17:24:32.974 SERIAL » [ACK] (0x06) 17:24:32.975 DRIVER « [REQ] [SendData] callback id: 43 transmit status: OK 17:24:33.078 SERIAL « 0x010a0004001c04810672110d (12 bytes) 17:24:33.078 SERIAL » [ACK] (0x06) 17:24:33.080 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[ClockCCReport] clock setting: Wednesday, 18:17 17:24:33.085 SERIAL » 0x0109001318027502252c81 (11 bytes) 17:24:33.085 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 44 └─[ProtectionCCGet] 17:24:33.086 CNTRLR « [Node 028] received current clock setting: Wednesday, 18:17 17:24:33.086 CNTRLR [Node 028] [~] [Clock] interviewComplete: true => true [Endpoint 0] [internal] 17:24:33.131 SERIAL « [ACK] (0x06) 17:24:33.136 SERIAL « 0x0104011301e8 (6 bytes) 17:24:33.137 SERIAL » [ACK] (0x06) 17:24:33.139 DRIVER « [RES] [SendData] was sent: true 17:24:33.141 CNTRLR [Node 028] AssociationCC: doing a partial interview... 17:24:33.142 CNTRLR [Node 028] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:24:33.142 CNTRLR [Node 028] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:24:33.142 CNTRLR [Node 028] MultiChannelAssociationCC: doing a partial interview... 17:24:33.143 CNTRLR » [Node 028] querying multi channel association group #1... 17:24:33.168 SERIAL « 0x010700132c000008cf (9 bytes) 17:24:33.169 SERIAL » [ACK] (0x06) 17:24:33.169 DRIVER « [REQ] [SendData] callback id: 44 transmit status: OK 17:24:33.182 SERIAL « 0x010a0004001804750300009b (12 bytes) 17:24:33.183 CNTRLR [Node 024] [~] [Protection] local: 0 => 0 [Endpoint 0] 17:24:33.185 CNTRLR [Node 024] [~] [Protection] rf: 0 => 0 [Endpoint 0] 17:24:33.188 SERIAL » [ACK] (0x06) 17:24:33.189 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 17:24:33.194 SERIAL » 0x010a00131c038e0201252d7c (12 bytes) 17:24:33.194 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 45 └─[MultiChannelAssociationCCGet] group id: 1 17:24:33.195 CNTRLR « [Node 024] received protection status: local: Unprotected rf Unprotected 17:24:33.196 CNTRLR [Node 024] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 17:24:33.196 CNTRLR [Node 024] AssociationCC: doing a partial interview... 17:24:33.196 CNTRLR [Node 024] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:24:33.197 CNTRLR [Node 024] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:24:33.197 CNTRLR [Node 024] MultiChannelAssociationCC: doing a partial interview... 17:24:33.197 CNTRLR » [Node 024] querying multi channel association group #1... 17:24:33.202 SERIAL « [ACK] (0x06) 17:24:33.204 SERIAL « 0x0104011301e8 (6 bytes) 17:24:33.205 SERIAL » [ACK] (0x06) 17:24:33.206 DRIVER « [RES] [SendData] was sent: true 17:24:33.259 SERIAL « 0x010700132d000007c1 (9 bytes) 17:24:33.260 SERIAL » [ACK] (0x06) 17:24:33.260 DRIVER « [REQ] [SendData] callback id: 45 transmit status: OK 17:24:33.346 SERIAL « 0x010e0004001c088e030101000001006d (16 bytes) 17:24:33.347 SERIAL » [ACK] (0x06) 17:24:33.348 CNTRLR [Node 028] [~] [Multi Channel Association] maxNodes[1]: 1 => 1 17:24:33.349 CNTRLR [Node 028] [~] [Multi Channel Association] nodeIds[1]: => 17:24:33.350 CNTRLR [Node 028] [~] [Multi Channel Association] endpoints[1]: [object Object] => [o bject Object] 17:24:33.351 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 1 node ids: endpoints: 1:0 17:24:33.354 SERIAL » 0x010a001318038e0201252e7b (12 bytes) 17:24:33.354 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 46 └─[MultiChannelAssociationCCGet] group id: 1 17:24:33.355 CNTRLR « [Node 028] received information for multi channel association group #1: maximum # of nodes: 1 currently assigned nodes: currently assigned endpoints: 1:0 17:24:33.355 CNTRLR [Node 028] [~] [Association] hasLifeline: true => true [internal] 17:24:33.356 CNTRLR [Node 028] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:24:33.356 CNTRLR [Node 028] AssociationGroupInfoCC: doing a partial interview... 17:24:33.356 CNTRLR [Node 028] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 17:24:33.357 CNTRLR [Node 028] NotificationCC: doing a partial interview... 17:24:33.357 CNTRLR [Node 028] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 17:24:33.357 CNTRLR [Node 028] Interview stage completed: CommandClasses 17:24:33.357 CNTRLR [Node 028] Interview stage completed: OverwriteConfig 17:24:33.358 CNTRLR » [Node 028] requesting node neighbors... 17:24:33.361 SERIAL « [ACK] (0x06) 17:24:33.363 SERIAL « 0x0104011301e8 (6 bytes) 17:24:33.364 SERIAL » [ACK] (0x06) 17:24:33.366 DRIVER « [RES] [SendData] was sent: true 17:24:33.438 SERIAL « 0x010700132e000009cc (9 bytes) 17:24:33.439 SERIAL » [ACK] (0x06) 17:24:33.439 DRIVER « [REQ] [SendData] callback id: 46 transmit status: OK 17:24:33.454 SERIAL « 0x010e00040018088e0301010000010069 (16 bytes) 17:24:33.454 SERIAL » [ACK] (0x06) 17:24:33.455 CNTRLR [Node 024] [~] [Multi Channel Association] maxNodes[1]: 1 => 1 17:24:33.456 CNTRLR [Node 024] [~] [Multi Channel Association] nodeIds[1]: => 17:24:33.457 CNTRLR [Node 024] [~] [Multi Channel Association] endpoints[1]: [object Object] => [o bject Object] 17:24:33.458 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 1 node ids: endpoints: 1:0 17:24:33.461 SERIAL » 0x010700801c00000064 (9 bytes) 17:24:33.461 DRIVER » [Node 028] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:24:33.462 CNTRLR « [Node 024] received information for multi channel association group #1: maximum # of nodes: 1 currently assigned nodes: currently assigned endpoints: 1:0 17:24:33.462 CNTRLR » [Node 024] querying multi channel association group #2... 17:24:33.465 SERIAL « [ACK] (0x06) 17:24:33.467 SERIAL « 0x0120018065f988530700000000000000000000000000000000000000000000000 (34 bytes) 01e 17:24:33.468 SERIAL » [ACK] (0x06) 17:24:33.470 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 9, 12, 13, 14, 15, 16, 20, 24, 25, 26, 29, 31, 33, 34, 35 17:24:33.477 SERIAL » 0x010a001318038e0202252f79 (12 bytes) 17:24:33.478 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 47 └─[MultiChannelAssociationCCGet] group id: 2 17:24:33.478 CNTRLR « [Node 028] node neighbors received: 1, 3, 6, 7, 9, 12, 13, 14, 15, 16, 20, 2 4, 25, 26, 29, 31, 33, 34, 35 17:24:33.478 CNTRLR [Node 028] Interview stage completed: Neighbors 17:24:33.512 SERIAL « [ACK] (0x06) 17:24:33.515 SERIAL « 0x0104011301e8 (6 bytes) 17:24:33.515 SERIAL » [ACK] (0x06) 17:24:33.517 DRIVER « [RES] [SendData] was sent: true 17:24:33.520 CNTRLR [Node 028] Interview completed 17:24:33.522 SERIAL « 0x010700132f000002c6 (9 bytes) 17:24:33.522 SERIAL » [ACK] (0x06) 17:24:33.523 DRIVER « [REQ] [SendData] callback id: 47 transmit status: OK 17:24:33.526 SERIAL « 0x010b00040018058e0302050067 (13 bytes) 17:24:33.527 SERIAL » [ACK] (0x06) 17:24:33.528 CNTRLR [Node 024] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 17:24:33.529 CNTRLR [Node 024] [~] [Multi Channel Association] nodeIds[2]: => 17:24:33.530 CNTRLR [Node 024] [~] [Multi Channel Association] endpoints[2]: => 17:24:33.531 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 17:24:33.536 SERIAL » 0x010a00131d03700501253099 (12 bytes) 17:24:33.537 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 48 └─[ConfigurationCCGet] parameter #: 1 17:24:33.537 CNTRLR « [Node 024] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 17:24:33.537 CNTRLR » [Node 024] querying multi channel association group #3... 17:24:33.541 SERIAL « [ACK] (0x06) 17:24:33.545 SERIAL « 0x0104011301e8 (6 bytes) 17:24:33.545 SERIAL » [ACK] (0x06) 17:24:33.546 DRIVER « [RES] [SendData] was sent: true 17:24:35.009 SERIAL « 0x010700133000009348 (9 bytes) 17:24:35.010 SERIAL » [ACK] (0x06) 17:24:35.011 DRIVER « [REQ] [SendData] callback id: 48 transmit status: OK 17:24:35.132 SERIAL « 0x010e0004001d08700601040000003caf (16 bytes) 17:24:35.144 CNTRLR [Node 029] [~] [Configuration] 1: 60 => 60 17:24:35.145 SERIAL » [ACK] (0x06) 17:24:35.147 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 4 value: 60 17:24:35.153 SERIAL » 0x010800131e01002531ef (10 bytes) 17:24:35.154 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 49 └─[NoOperationCC] 17:24:35.155 CNTRLR « [Node 029] parameter #1 has value: 60 17:24:35.155 CNTRLR » [Node 029] querying parameter #2 value... 17:24:35.161 SERIAL « [ACK] (0x06) 17:24:35.164 SERIAL « 0x0104011301e8 (6 bytes) 17:24:35.165 SERIAL » [ACK] (0x06) 17:24:35.168 DRIVER « [RES] [SendData] was sent: true 17:24:37.740 SERIAL « 0x01090004001b033003ff26 (11 bytes) 17:24:37.741 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:24:37.742 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:24:37.742 SERIAL » [ACK] (0x06) 17:24:37.743 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:24:37.901 SERIAL « 0x01090004101b033003ff36 (11 bytes) 17:24:37.902 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:24:37.902 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:24:37.903 SERIAL » [ACK] (0x06) 17:24:37.904 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:24:37.914 SERIAL « 0x01090004101b033003ff36 (11 bytes) 17:24:37.915 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:24:37.915 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:24:37.915 SERIAL » [ACK] (0x06) 17:24:37.916 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:24:37.949 SERIAL « 0x01090004101b033003ff36 (11 bytes) 17:24:37.949 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:24:37.950 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:24:37.950 SERIAL » [ACK] (0x06) 17:24:37.951 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:24:37.980 SERIAL « 0x01090004101b033003ff36 (11 bytes) 17:24:37.981 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:24:37.981 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:24:37.982 SERIAL » [ACK] (0x06) 17:24:37.983 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:24:38.050 SERIAL « 0x01090004101b033003ff36 (11 bytes) 17:24:38.051 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:24:38.051 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:24:38.051 SERIAL » [ACK] (0x06) 17:24:38.052 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:24:38.066 SERIAL « 0x01090004101b033003ff36 (11 bytes) 17:24:38.066 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:24:38.067 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:24:38.067 SERIAL » [ACK] (0x06) 17:24:38.068 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:24:38.145 SERIAL « 0x01090004001b032001ff34 (11 bytes) 17:24:38.146 SERIAL » [ACK] (0x06) 17:24:38.147 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:24:38.151 CNTRLR [Node 027] treating BasicCC Set as a report 17:24:38.152 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:24:38.313 SERIAL « 0x01090004101b033003ff36 (11 bytes) 17:24:38.314 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:24:38.315 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:24:38.316 SERIAL » [ACK] (0x06) 17:24:38.317 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:24:38.585 SERIAL « 0x01080004001b02840769 (10 bytes) 17:24:38.585 SERIAL » [ACK] (0x06) 17:24:38.586 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:24:38.587 CNTRLR « [Node 027] received wakeup notification 17:24:38.587 CNTRLR [Node 027] The node is now awake. 17:24:40.843 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 17:24:40.844 SERIAL » [ACK] (0x06) 17:24:40.846 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 17:24:40.848 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 17:24:42.832 SERIAL « 0x0107001331010300d8 (9 bytes) 17:24:42.832 SERIAL » [ACK] (0x06) 17:24:42.833 DRIVER « [REQ] [SendData] callback id: 49 transmit status: NoAck 17:24:42.842 SERIAL » 0x010800131f01002532ed (10 bytes) 17:24:42.842 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 50 └─[NoOperationCC] 17:24:42.843 CNTRLR [Node 030] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 17:24:42.844 CNTRLR [Node 030] The node is asleep. 17:24:42.845 CNTRLR [Node 030] The node is ready to be used 17:24:42.847 CNTRLR [Node 030] ping failed: Failed to send the command after 1 attempts (Status No Ack) 17:24:42.850 CNTRLR [Node 030] ManufacturerSpecificCC: doing a partial interview... 17:24:42.851 CNTRLR [Node 030] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:24:42.922 SERIAL « [ACK] (0x06) 17:24:42.924 SERIAL « 0x0104011301e8 (6 bytes) 17:24:42.925 SERIAL » [ACK] (0x06) 17:24:42.930 DRIVER « [RES] [SendData] was sent: true 17:24:42.934 SERIAL « 0x0107001332000002db (9 bytes) 17:24:42.935 SERIAL » [ACK] (0x06) 17:24:42.936 DRIVER « [REQ] [SendData] callback id: 50 transmit status: OK 17:24:42.943 SERIAL » 0x010a00131d03700502253399 (12 bytes) 17:24:42.944 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 51 └─[ConfigurationCCGet] parameter #: 2 17:24:42.944 CNTRLR « [Node 031] ping successful 17:24:42.945 CNTRLR [Node 031] ManufacturerSpecificCC: doing a partial interview... 17:24:42.946 CNTRLR [Node 031] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:24:42.946 CNTRLR [Node 031] VersionCC: doing a partial interview... 17:24:42.946 CNTRLR [Node 031] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:24:42.947 CNTRLR [Node 031] trying to load device config 17:24:42.948 CNTRLR [Node 030] VersionCC: doing a partial interview... 17:24:42.949 CNTRLR [Node 030] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:24:42.949 CNTRLR [Node 030] trying to load device config 17:24:42.953 SERIAL « 0x010c00040003063105042209729b (14 bytes) 17:24:42.954 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:24:42.955 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 186.7 => 241.8 [Endpoint 0] 17:24:42.955 SERIAL » [ACK] (0x06) 17:24:42.955 SERIAL « [CAN] (0x18) 17:24:42.956 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 17:24:42.958 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 241.8 17:24:42.972 CNTRLR [Node 031] device config loaded 17:24:42.972 CNTRLR » [Node 031] querying device endpoint information... 17:24:42.985 CNTRLR [Node 030] device config loaded 17:24:42.986 CNTRLR [Node 030] BatteryCC: doing a partial interview... 17:24:42.986 CNTRLR » [Node 030] querying battery status... 17:24:43.218 SERIAL » 0x010a00131d03700502253399 (12 bytes) 17:24:43.219 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 51 └─[ConfigurationCCGet] parameter #: 2 17:24:43.249 SERIAL « [ACK] (0x06) 17:24:43.250 SERIAL « 0x0104011301e8 (6 bytes) 17:24:43.250 SERIAL » [ACK] (0x06) 17:24:43.253 DRIVER « [RES] [SendData] was sent: true 17:24:44.691 SERIAL « 0x01070013330000934b (9 bytes) 17:24:44.692 SERIAL » [ACK] (0x06) 17:24:44.695 DRIVER « [REQ] [SendData] callback id: 51 transmit status: OK 17:24:44.813 SERIAL « 0x010e0004001d08700602040000000191 (16 bytes) 17:24:44.824 CNTRLR [Node 029] [~] [Configuration] 2: 1 => 1 17:24:44.825 SERIAL » [ACK] (0x06) 17:24:44.827 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 4 value: 1 17:24:44.838 SERIAL » 0x010900131f02600725348e (11 bytes) 17:24:44.839 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 52 └─[MultiChannelCCEndPointGet] 17:24:44.840 CNTRLR « [Node 029] parameter #2 has value: 1 17:24:44.841 CNTRLR » [Node 029] querying parameter #3 value... 17:24:44.849 SERIAL « [ACK] (0x06) 17:24:44.851 SERIAL « 0x0104011301e8 (6 bytes) 17:24:44.852 SERIAL » [ACK] (0x06) 17:24:44.853 DRIVER « [RES] [SendData] was sent: true 17:24:44.876 SERIAL « 0x010c000400030631050422046c88 (14 bytes) 17:24:44.879 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:24:44.880 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 241.8 => 113.2 [Endpoint 0] 17:24:44.882 SERIAL » [ACK] (0x06) 17:24:44.884 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 113.2 17:24:44.913 SERIAL « 0x0107001334000007d8 (9 bytes) 17:24:44.914 SERIAL » [ACK] (0x06) 17:24:44.914 DRIVER « [REQ] [SendData] callback id: 52 transmit status: OK 17:24:44.924 SERIAL « 0x010a0004001f0460084002c0 (12 bytes) 17:24:44.926 CNTRLR [Node 031] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 17:24:44.926 CNTRLR [Node 031] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 17:24:44.926 CNTRLR [Node 031] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 17:24:44.926 SERIAL » [ACK] (0x06) 17:24:44.927 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: true 17:24:44.931 SERIAL » 0x010a00131d0370050325359e (12 bytes) 17:24:44.932 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 53 └─[ConfigurationCCGet] parameter #: 3 17:24:44.932 CNTRLR [Node 031] The node is alive. 17:24:44.933 CNTRLR [Node 031] The node is ready to be used 17:24:44.934 CNTRLR « [Node 031] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: true 17:24:44.935 CNTRLR [Node 031] does not support EndPointFind, assuming that endpoints are sequenti al 17:24:44.935 CNTRLR » [Node 031] querying capabilities for endpoint #1... 17:24:44.941 SERIAL « [ACK] (0x06) 17:24:44.943 SERIAL « 0x0104011301e8 (6 bytes) 17:24:44.943 SERIAL » [ACK] (0x06) 17:24:44.944 DRIVER « [RES] [SendData] was sent: true 17:24:45.185 SERIAL « 0x0107001335000009d7 (9 bytes) 17:24:45.186 SERIAL » [ACK] (0x06) 17:24:45.186 DRIVER « [REQ] [SendData] callback id: 53 transmit status: OK 17:24:45.189 SERIAL « 0x010e0004001d08700603040000000091 (16 bytes) 17:24:45.195 CNTRLR [Node 029] [~] [Configuration] 3: 0 => 0 17:24:45.196 SERIAL » [ACK] (0x06) 17:24:45.197 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 4 value: 0 17:24:45.200 SERIAL » 0x010a00131f03600901253681 (12 bytes) 17:24:45.201 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 54 └─[MultiChannelCCCapabilityGet] endpoint: 1 17:24:45.201 CNTRLR « [Node 029] parameter #3 has value: 0 17:24:45.201 CNTRLR [Node 029] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:24:45.245 SERIAL « [ACK] (0x06) 17:24:45.250 SERIAL « 0x0104011301e8 (6 bytes) 17:24:45.251 SERIAL » [ACK] (0x06) 17:24:45.253 DRIVER « [RES] [SendData] was sent: true 17:24:45.256 CNTRLR [Node 029] ProtectionCC: doing a partial interview... 17:24:45.257 CNTRLR » [Node 029] querying protection status... 17:24:45.261 SERIAL « 0x0107001336000002df (9 bytes) 17:24:45.262 SERIAL » [ACK] (0x06) 17:24:45.264 DRIVER « [REQ] [SendData] callback id: 54 transmit status: OK 17:24:45.270 SERIAL « 0x010c0004001f06600a01100125b1 (14 bytes) 17:24:45.271 CNTRLR [Node 031] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 1] [internal] 7 17:24:45.271 SERIAL » [ACK] (0x06) 17:24:45.272 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 17:24:45.276 SERIAL » 0x010900131d02750225379f (11 bytes) 17:24:45.276 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 55 └─[ProtectionCCGet] 17:24:45.277 CNTRLR « [Node 031] received response for endpoint capabilities (#1): generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Binary Switch 17:24:45.277 CNTRLR [Node 031] all endpoints idendical, skipping capability query for endpoint #2. .. 17:24:45.277 CNTRLR [Node 031] [~] [Multi Channel] commandClasses: 37 => 3 [Endpoint 2] [internal] 7 17:24:45.278 CNTRLR [Node 031] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 17:24:45.278 CNTRLR [Node 031] AssociationCC: doing a partial interview... 17:24:45.278 CNTRLR [Node 031] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:24:45.279 CNTRLR [Node 031] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:24:45.279 CNTRLR [Node 031] BinarySwitchCC: doing a partial interview... [Endpoint 1] 17:24:45.279 CNTRLR » [Node 031] querying Binary Switch state... [Endpoint 1] 17:24:45.283 SERIAL « [ACK] (0x06) 17:24:45.285 SERIAL « 0x0104011301e8 (6 bytes) 17:24:45.285 SERIAL » [ACK] (0x06) 17:24:45.286 DRIVER « [RES] [SendData] was sent: true 17:24:45.366 SERIAL « 0x0107001337000008d4 (9 bytes) 17:24:45.367 SERIAL » [ACK] (0x06) 17:24:45.367 DRIVER « [REQ] [SendData] callback id: 55 transmit status: OK 17:24:45.468 SERIAL « 0x01090004001d037503009a (11 bytes) 17:24:45.469 CNTRLR [Node 029] [~] [Protection] local: 0 => 0 [Endpoint 0] 17:24:45.470 SERIAL » [ACK] (0x06) 17:24:45.471 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected 17:24:45.474 SERIAL » 0x010d00131f06600d000125022538ae (15 bytes) 17:24:45.475 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 56 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 17:24:45.475 CNTRLR « [Node 029] received protection status: local: Unprotected 17:24:45.476 CNTRLR [Node 029] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 17:24:45.476 CNTRLR [Node 029] ClockCC: doing a partial interview... 17:24:45.476 CNTRLR » [Node 029] requesting current clock setting... 17:24:45.480 SERIAL « [ACK] (0x06) 17:24:45.485 SERIAL « 0x0104011301e8 (6 bytes) 17:24:45.486 SERIAL » [ACK] (0x06) 17:24:45.487 DRIVER « [RES] [SendData] was sent: true 17:24:45.535 SERIAL « 0x0107001338000006d5 (9 bytes) 17:24:45.536 SERIAL » [ACK] (0x06) 17:24:45.537 DRIVER « [REQ] [SendData] callback id: 56 transmit status: OK 17:24:45.547 SERIAL « 0x010d0004001f07600d01002503ff5b (15 bytes) 17:24:45.548 CNTRLR [Node 031] [~] [Binary Switch] currentValue: true => true [Endpoint 1] 17:24:45.549 SERIAL » [ACK] (0x06) 17:24:45.551 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: true 17:24:45.555 SERIAL » 0x010900131d028105253962 (11 bytes) 17:24:45.555 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 57 └─[ClockCCGet] 17:24:45.556 CNTRLR « [Node 031] received Binary Switch state: [Endpoint 1] current value: true 17:24:45.556 CNTRLR [Node 031] [~] [Binary Switch] interviewComplete: true [Endpoint 1] [internal] => true 17:24:45.557 CNTRLR [Node 031] BinarySwitchCC: doing a partial interview... [Endpoint 2] 17:24:45.557 CNTRLR » [Node 031] querying Binary Switch state... [Endpoint 2] 17:24:45.561 SERIAL « [ACK] (0x06) 17:24:45.564 SERIAL « 0x0104011301e8 (6 bytes) 17:24:45.564 SERIAL » [ACK] (0x06) 17:24:45.566 DRIVER « [RES] [SendData] was sent: true 17:24:45.643 SERIAL « 0x0107001339000009db (9 bytes) 17:24:45.644 SERIAL » [ACK] (0x06) 17:24:45.644 DRIVER « [REQ] [SendData] callback id: 57 transmit status: OK 17:24:45.727 SERIAL « 0x010a0004001d048106721805 (12 bytes) 17:24:45.728 SERIAL » [ACK] (0x06) 17:24:45.729 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ClockCCReport] clock setting: Wednesday, 18:24 17:24:45.732 SERIAL » 0x010d00131f06600d00022502253aaf (15 bytes) 17:24:45.733 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 58 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[BinarySwitchCCGet] 17:24:45.733 CNTRLR « [Node 029] received current clock setting: Wednesday, 18:24 17:24:45.734 CNTRLR [Node 029] [~] [Clock] interviewComplete: true => true [Endpoint 0] [internal] 17:24:45.785 SERIAL « [ACK] (0x06) 17:24:45.788 SERIAL « 0x0104011301e8 (6 bytes) 17:24:45.789 SERIAL » [ACK] (0x06) 17:24:45.790 DRIVER « [RES] [SendData] was sent: true 17:24:45.793 CNTRLR [Node 029] AssociationCC: doing a partial interview... 17:24:45.793 CNTRLR [Node 029] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:24:45.794 CNTRLR [Node 029] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:24:45.794 CNTRLR [Node 029] MultiChannelAssociationCC: doing a partial interview... 17:24:45.794 CNTRLR » [Node 029] querying multi channel association group #1... 17:24:45.815 SERIAL « 0x010700133a000008d9 (9 bytes) 17:24:45.816 SERIAL » [ACK] (0x06) 17:24:45.817 DRIVER « [REQ] [SendData] callback id: 58 transmit status: OK 17:24:45.829 SERIAL « 0x010d0004001f07600d0200250300a7 (15 bytes) 17:24:45.830 CNTRLR [Node 031] [~] [Binary Switch] currentValue: false => false [Endpoint 2] 17:24:45.830 SERIAL » [ACK] (0x06) 17:24:45.832 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BinarySwitchCCReport] current value: false 17:24:45.836 SERIAL » 0x01080013200100253bdb (10 bytes) 17:24:45.836 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 59 └─[NoOperationCC] 17:24:45.837 CNTRLR « [Node 031] received Binary Switch state: [Endpoint 2] current value: false 17:24:45.837 CNTRLR [Node 031] [~] [Binary Switch] interviewComplete: true [Endpoint 2] [internal] => true 17:24:45.837 CNTRLR [Node 031] BinarySwitchCC: doing a partial interview... 17:24:45.837 CNTRLR » [Node 031] querying Binary Switch state... 17:24:45.842 SERIAL « [ACK] (0x06) 17:24:45.844 SERIAL « 0x0104011301e8 (6 bytes) 17:24:45.845 SERIAL » [ACK] (0x06) 17:24:45.846 DRIVER « [RES] [SendData] was sent: true 17:24:45.896 SERIAL « 0x010c000400030631050422054ca9 (14 bytes) 17:24:45.897 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:24:45.897 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 113.2 => 135.6 [Endpoint 0] 17:24:45.898 SERIAL » [ACK] (0x06) 17:24:45.899 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 135.6 17:24:48.588 DRIVER The awake timeout for node 27 has elapsed. Assuming it is asleep. 17:24:48.588 CNTRLR [Node 027] The node is now asleep. 17:24:50.388 SERIAL « 0x010700133b0101c616 (9 bytes) 17:24:50.389 SERIAL » [ACK] (0x06) 17:24:50.390 DRIVER « [REQ] [SendData] callback id: 59 transmit status: NoAck 17:24:50.400 SERIAL » 0x01080013210100253cdd (10 bytes) 17:24:50.401 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 60 └─[NoOperationCC] 17:24:50.402 CNTRLR [Node 032] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 17:24:50.402 CNTRLR [Node 032] The node is asleep. 17:24:50.405 CNTRLR [Node 032] The node is ready to be used 17:24:50.407 CNTRLR [Node 032] ping failed: Failed to send the command after 1 attempts (Status No Ack) 17:24:50.411 CNTRLR [Node 032] ManufacturerSpecificCC: doing a partial interview... 17:24:50.412 CNTRLR [Node 032] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:24:50.417 SERIAL « [ACK] (0x06) 17:24:50.419 SERIAL « 0x0104011301e8 (6 bytes) 17:24:50.420 SERIAL » [ACK] (0x06) 17:24:50.471 DRIVER « [RES] [SendData] was sent: true 17:24:50.478 SERIAL « 0x010700133c000002d5 (9 bytes) 17:24:50.479 SERIAL » [ACK] (0x06) 17:24:50.480 CNTRLR [Node 032] VersionCC: doing a partial interview... 17:24:50.480 CNTRLR [Node 032] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:24:50.481 CNTRLR [Node 032] trying to load device config 17:24:50.482 DRIVER « [REQ] [SendData] callback id: 60 transmit status: OK 17:24:50.487 SERIAL » 0x01080013220100253ddf (10 bytes) 17:24:50.487 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 61 └─[NoOperationCC] 17:24:50.488 CNTRLR « [Node 033] ping successful 17:24:50.489 CNTRLR [Node 033] ManufacturerSpecificCC: doing a partial interview... 17:24:50.489 CNTRLR [Node 033] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:24:50.490 CNTRLR [Node 033] VersionCC: doing a partial interview... 17:24:50.490 CNTRLR [Node 033] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:24:50.490 CNTRLR [Node 033] trying to load device config 17:24:50.494 SERIAL « [ACK] (0x06) 17:24:50.496 SERIAL « 0x0104011301e8 (6 bytes) 17:24:50.496 SERIAL » [ACK] (0x06) 17:24:50.497 DRIVER « [RES] [SendData] was sent: true 17:24:50.508 CNTRLR [Node 032] device config loaded 17:24:50.508 CNTRLR [Node 032] BatteryCC: doing a partial interview... 17:24:50.508 CNTRLR » [Node 032] querying battery status... 17:24:50.517 CNTRLR [Node 033] device config loaded 17:24:50.518 CNTRLR » [Node 033] querying device endpoint information... 17:24:50.520 SERIAL « 0x010700133d000002d4 (9 bytes) 17:24:50.520 SERIAL » [ACK] (0x06) 17:24:50.521 DRIVER « [REQ] [SendData] callback id: 61 transmit status: OK 17:24:50.528 SERIAL » 0x01080013230100253edd (10 bytes) 17:24:50.528 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 62 └─[NoOperationCC] 17:24:50.529 CNTRLR « [Node 034] ping successful 17:24:50.531 CNTRLR [Node 034] ManufacturerSpecificCC: doing a partial interview... 17:24:50.531 CNTRLR [Node 034] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:24:50.532 CNTRLR [Node 034] VersionCC: doing a partial interview... 17:24:50.532 CNTRLR [Node 034] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:24:50.532 CNTRLR [Node 034] trying to load device config 17:24:50.535 SERIAL « [ACK] (0x06) 17:24:50.537 SERIAL « 0x0104011301e8 (6 bytes) 17:24:50.538 SERIAL » [ACK] (0x06) 17:24:50.538 DRIVER « [RES] [SendData] was sent: true 17:24:50.556 CNTRLR [Node 034] device config loaded 17:24:50.557 CNTRLR [Node 034] ZWavePlusCC: doing a partial interview... 17:24:50.557 CNTRLR [Node 034] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 17:24:50.557 CNTRLR » [Node 034] querying device endpoint information... 17:24:51.924 SERIAL « 0x010700133e00008b5e (9 bytes) 17:24:51.925 SERIAL » [ACK] (0x06) 17:24:51.926 DRIVER « [REQ] [SendData] callback id: 62 transmit status: OK 17:24:51.935 SERIAL » 0x010900131f022502253fc5 (11 bytes) 17:24:51.936 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 63 └─[BinarySwitchCCGet] 17:24:51.936 CNTRLR « [Node 035] ping successful 17:24:51.940 CNTRLR [Node 035] ManufacturerSpecificCC: doing a partial interview... 17:24:51.941 CNTRLR [Node 035] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 17:24:51.987 SERIAL « [ACK] (0x06) 17:24:51.991 SERIAL « 0x0104011301e8 (6 bytes) 17:24:51.991 SERIAL » [ACK] (0x06) 17:24:51.992 DRIVER « [RES] [SendData] was sent: true 17:24:51.995 SERIAL « 0x010700133f000002d6 (9 bytes) 17:24:51.995 SERIAL » [ACK] (0x06) 17:24:51.996 CNTRLR [Node 035] VersionCC: doing a partial interview... 17:24:51.997 CNTRLR [Node 035] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:24:51.997 CNTRLR [Node 035] trying to load device config 17:24:51.999 DRIVER « [REQ] [SendData] callback id: 63 transmit status: OK 17:24:52.002 SERIAL « 0x01090004001f032503ff37 (11 bytes) 17:24:52.003 CNTRLR [Node 031] [~] [Binary Switch] currentValue: true => true [Endpoint 0] 17:24:52.004 SERIAL » [ACK] (0x06) 17:24:52.005 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: true 17:24:52.009 SERIAL » 0x010a001303038e020125400e (12 bytes) 17:24:52.010 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 64 └─[MultiChannelAssociationCCGet] group id: 1 17:24:52.010 CNTRLR « [Node 031] received Binary Switch state: current value: true 17:24:52.011 CNTRLR [Node 031] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 17:24:52.011 CNTRLR [Node 031] ConfigurationCC: Loading configuration parameters from device confi g 17:24:52.017 CNTRLR [Node 031] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:24:52.017 CNTRLR [Node 031] [Configuration] 1: metadata updated 17:24:52.019 CNTRLR [Node 031] [Configuration] 3: metadata updated 17:24:52.020 CNTRLR [Node 031] [Configuration] 4: metadata updated 17:24:52.021 CNTRLR [Node 031] [Configuration] 5: metadata updated 17:24:52.022 CNTRLR [Node 031] [Configuration] 6: metadata updated 17:24:52.023 CNTRLR [Node 031] [Configuration] 7: metadata updated 17:24:52.024 CNTRLR [Node 031] [Configuration] 13: metadata updated 17:24:52.025 CNTRLR [Node 031] [Configuration] 14: metadata updated 17:24:52.027 CNTRLR [Node 031] [Configuration] 15: metadata updated 17:24:52.028 CNTRLR [Node 031] [Configuration] 16: metadata updated 17:24:52.029 CNTRLR [Node 031] [Configuration] 30: metadata updated 17:24:52.030 CNTRLR [Node 031] [Configuration] 31: metadata updated 17:24:52.031 CNTRLR [Node 031] [Configuration] 32: metadata updated 17:24:52.032 CNTRLR [Node 031] [Configuration] 33: metadata updated 17:24:52.033 CNTRLR [Node 031] [Configuration] 39: metadata updated 17:24:52.035 CNTRLR [Node 031] [Configuration] 40: metadata updated 17:24:52.036 CNTRLR [Node 031] [Configuration] 41: metadata updated 17:24:52.037 CNTRLR [Node 031] [Configuration] 42: metadata updated 17:24:52.038 CNTRLR [Node 031] [Configuration] 43: metadata updated 17:24:52.039 CNTRLR [Node 031] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:24:52.039 CNTRLR » [Node 031] querying parameter #1 value... 17:24:52.047 CNTRLR [Node 035] device config loaded 17:24:52.048 CNTRLR [Node 035] ZWavePlusCC: doing a partial interview... 17:24:52.049 CNTRLR [Node 035] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 17:24:52.049 CNTRLR » [Node 035] querying device endpoint information... 17:24:52.052 SERIAL « [ACK] (0x06) 17:24:52.053 SERIAL « 0x0104011301e8 (6 bytes) 17:24:52.054 SERIAL » [ACK] (0x06) 17:24:52.056 DRIVER « [RES] [SendData] was sent: true 17:24:52.065 SERIAL « 0x0107001340000002a9 (9 bytes) 17:24:52.065 SERIAL » [ACK] (0x06) 17:24:52.067 DRIVER « [REQ] [SendData] callback id: 64 transmit status: OK 17:24:52.071 SERIAL « 0x010b00040003058e030105007f (13 bytes) 17:24:52.071 SERIAL » [ACK] (0x06) 17:24:52.073 CNTRLR [Node 003] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 17:24:52.075 CNTRLR [Node 003] [~] [Multi Channel Association] nodeIds[1]: => 17:24:52.076 CNTRLR [Node 003] [~] [Multi Channel Association] endpoints[1]: => 17:24:52.077 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: endpoints: 17:24:52.086 SERIAL » 0x010900130602984025415d (11 bytes) 17:24:52.087 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 65 └─[SecurityCCNonceGet] 17:24:52.088 CNTRLR « [Node 003] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 17:24:52.088 CNTRLR » [Node 003] querying multi channel association group #2... 17:24:52.096 SERIAL « [ACK] (0x06) 17:24:52.098 SERIAL « 0x0104011301e8 (6 bytes) 17:24:52.099 SERIAL » [ACK] (0x06) 17:24:52.100 DRIVER « [RES] [SendData] was sent: true 17:24:53.467 SERIAL « 0x010700134100008923 (9 bytes) 17:24:53.468 SERIAL » [ACK] (0x06) 17:24:53.469 DRIVER « [REQ] [SendData] callback id: 65 transmit status: OK 17:24:53.555 SERIAL « 0x0110000400060a9880f63bb2b95d985e47e5 (18 bytes) 17:24:53.557 SERIAL » [ACK] (0x06) 17:24:53.559 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xf63bb2b95d985e47 17:24:53.574 SERIAL » 0x011e00130617988169f63ad9eff5db92c5114f37f663faa3f5e5a870aa2542b0 (32 bytes) 17:24:53.575 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 66 └─[SecurityCCCommandEncapsulation] │ nonce id: 246 └─[MultiChannelAssociationCCGet] group id: 1 17:24:53.579 SERIAL « [ACK] (0x06) 17:24:53.586 SERIAL « 0x0104011301e8 (6 bytes) 17:24:53.587 SERIAL » [ACK] (0x06) 17:24:53.587 DRIVER « [RES] [SendData] was sent: true 17:24:53.697 SERIAL « 0x010700134200000ba2 (9 bytes) 17:24:53.697 SERIAL » [ACK] (0x06) 17:24:53.698 DRIVER « [REQ] [SendData] callback id: 66 transmit status: OK 17:24:53.781 SERIAL « 0x0108000400060298402f (10 bytes) 17:24:53.782 SERIAL » [ACK] (0x06) 17:24:53.784 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:24:53.797 SERIAL » 0x01110013060a9880029f55ded0d3bc7a05437c (19 bytes) 17:24:53.798 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 67 └─[SecurityCCNonceReport] nonce: 0x029f55ded0d3bc7a 17:24:53.800 SERIAL « [ACK] (0x06) 17:24:53.806 SERIAL « 0x0104011301e8 (6 bytes) 17:24:53.807 SERIAL » [ACK] (0x06) 17:24:53.808 DRIVER « [RES] [SendData] was sent: true 17:24:53.923 SERIAL « 0x010700134300000ca4 (9 bytes) 17:24:53.924 SERIAL » [ACK] (0x06) 17:24:53.925 DRIVER « [REQ] [SendData] callback id: 67 transmit status: OK 17:24:54.014 SERIAL « 0x0122000400061c98811fabe53495b9afa7a096088104b7bb985802fd18f519f36 (36 bytes) bbf8d4d 17:24:54.019 SERIAL » [ACK] (0x06) 17:24:54.022 CNTRLR [Node 006] [~] [Multi Channel Association] maxNodes[1]: 1 => 1 17:24:54.023 CNTRLR [Node 006] [~] [Multi Channel Association] nodeIds[1]: => 17:24:54.025 CNTRLR [Node 006] [~] [Multi Channel Association] endpoints[1]: [object Object] => [o bject Object] 17:24:54.026 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 1 node ids: endpoints: 1:0 17:24:54.033 SERIAL » 0x010c00130c0591010f2602254433 (14 bytes) 17:24:54.034 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 68 └─[FibaroVenetianBlindCCGet] payload: 0x0f2602 17:24:54.035 CNTRLR « [Node 006] received information for multi channel association group #1: maximum # of nodes: 1 currently assigned nodes: currently assigned endpoints: 1:0 17:24:54.035 CNTRLR [Node 006] [~] [Association] hasLifeline: true => true [internal] 17:24:54.036 CNTRLR [Node 006] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:24:54.095 SERIAL « [ACK] (0x06) 17:24:54.101 SERIAL « 0x0104011301e8 (6 bytes) 17:24:54.102 SERIAL » [ACK] (0x06) 17:24:54.107 DRIVER « [RES] [SendData] was sent: true 17:24:54.112 CNTRLR [Node 006] AssociationGroupInfoCC: doing a partial interview... 17:24:54.113 CNTRLR [Node 006] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 17:24:54.114 CNTRLR [Node 006] NotificationCC: doing a partial interview... 17:24:54.115 CNTRLR » [Node 006] querying notification status for Power Management... 17:24:54.122 SERIAL « 0x0107001344000007a8 (9 bytes) 17:24:54.122 SERIAL » [ACK] (0x06) 17:24:54.125 DRIVER « [REQ] [SendData] callback id: 68 transmit status: OK 17:24:54.134 SERIAL « 0x010e0004000c0891010f26030263002a (16 bytes) 17:24:54.137 CNTRLR [Node 012] [Manufacturer Proprietary] fibaro[venetianBlindsPositi [Endpoint 0] on]: metadata updated 17:24:54.138 CNTRLR [Node 012] [~] [Manufacturer Proprietary] fibaro[venetianBlindsPo [Endpoint 0] sition]: 99 => 99 17:24:54.139 SERIAL » [ACK] (0x06) 17:24:54.141 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[FibaroVenetianBlindCCReport] position: 99 17:24:54.145 SERIAL » 0x010c0013100591010f260225452e (14 bytes) 17:24:54.145 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 69 └─[FibaroVenetianBlindCCGet] payload: 0x0f2602 17:24:54.146 CNTRLR « [Node 012] received venetian blind state: position: 99 tilt: undefined 17:24:54.146 CNTRLR [Node 012] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 17:24:54.146 CNTRLR [Node 012] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 17:24:54.146 CNTRLR [Node 012] Interview stage completed: CommandClasses 17:24:54.147 CNTRLR [Node 012] Interview stage completed: OverwriteConfig 17:24:54.147 CNTRLR » [Node 012] requesting node neighbors... 17:24:54.152 SERIAL « [ACK] (0x06) 17:24:54.155 SERIAL « 0x0104011301e8 (6 bytes) 17:24:54.155 SERIAL » [ACK] (0x06) 17:24:54.156 DRIVER « [RES] [SendData] was sent: true 17:24:54.193 SERIAL « 0x0107001345000005ab (9 bytes) 17:24:54.197 SERIAL » [ACK] (0x06) 17:24:54.198 DRIVER « [REQ] [SendData] callback id: 69 transmit status: OK 17:24:54.242 SERIAL « 0x010e000400100891010f260302630036 (16 bytes) 17:24:54.243 CNTRLR [Node 016] [Manufacturer Proprietary] fibaro[venetianBlindsPositi [Endpoint 0] on]: metadata updated 17:24:54.244 CNTRLR [Node 016] [~] [Manufacturer Proprietary] fibaro[venetianBlindsPo [Endpoint 0] sition]: 1 => 99 17:24:54.245 SERIAL » [ACK] (0x06) 17:24:54.246 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[FibaroVenetianBlindCCReport] position: 99 17:24:54.249 SERIAL » 0x010700800c00000074 (9 bytes) 17:24:54.249 DRIVER » [Node 012] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:24:54.250 CNTRLR « [Node 016] received venetian blind state: position: 99 tilt: undefined 17:24:54.250 CNTRLR [Node 016] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 17:24:54.251 CNTRLR [Node 016] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 17:24:54.251 CNTRLR [Node 016] Interview stage completed: CommandClasses 17:24:54.251 CNTRLR [Node 016] Interview stage completed: OverwriteConfig 17:24:54.251 CNTRLR » [Node 016] requesting node neighbors... 17:24:54.255 SERIAL « [ACK] (0x06) 17:24:54.256 SERIAL « 0x0120018065f3bc6b0300000000000000000000000000000000000000000000000 (34 bytes) 01c 17:24:54.257 SERIAL » [ACK] (0x06) 17:24:54.258 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 9, 10, 13, 14, 15, 16, 19, 20, 21, 22, 24, 25, 26, 28, 30, 31, 33, 34 17:24:54.271 SERIAL » 0x010700801000000068 (9 bytes) 17:24:54.272 DRIVER » [Node 016] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:24:54.272 CNTRLR « [Node 012] node neighbors received: 1, 3, 6, 7, 9, 10, 13, 14, 15, 16, 19, 2 0, 21, 22, 24, 25, 26, 28, 30, 31, 33, 34 17:24:54.272 CNTRLR [Node 012] Interview stage completed: Neighbors 17:24:54.314 SERIAL « [ACK] (0x06) 17:24:54.317 SERIAL « 0x012001802579fd290700000000000000000000000000000000000000000000000 (34 bytes) 0d1 17:24:54.318 SERIAL » [ACK] (0x06) 17:24:54.319 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 9, 12, 13, 14, 15, 17, 19, 20, 21, 22, 23, 24, 25, 28, 30 , 33, 34, 35 17:24:54.325 SERIAL » 0x010c00131a0591010f2602254627 (14 bytes) 17:24:54.325 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 70 └─[FibaroVenetianBlindCCGet] payload: 0x0f2602 17:24:54.326 CNTRLR « [Node 016] node neighbors received: 1, 3, 6, 9, 12, 13, 14, 15, 17, 19, 20, 21, 22, 23, 24, 25, 28, 30, 33, 34, 35 17:24:54.326 CNTRLR [Node 016] Interview stage completed: Neighbors 17:24:54.326 CNTRLR [Node 016] Interview completed 17:24:54.328 CNTRLR [Node 012] Interview completed 17:24:54.330 SERIAL « [ACK] (0x06) 17:24:54.333 SERIAL « 0x0104011301e8 (6 bytes) 17:24:54.334 SERIAL » [ACK] (0x06) 17:24:54.335 DRIVER « [RES] [SendData] was sent: true 17:24:54.373 SERIAL « 0x0107001346000005a8 (9 bytes) 17:24:54.373 SERIAL » [ACK] (0x06) 17:24:54.374 DRIVER « [REQ] [SendData] callback id: 70 transmit status: OK 17:24:54.422 SERIAL « 0x010e0004001a0891010f26030263003c (16 bytes) 17:24:54.423 CNTRLR [Node 026] [Manufacturer Proprietary] fibaro[venetianBlindsPositi [Endpoint 0] on]: metadata updated 17:24:54.424 CNTRLR [Node 026] [~] [Manufacturer Proprietary] fibaro[venetianBlindsPo [Endpoint 0] sition]: 1 => 99 17:24:54.424 SERIAL » [ACK] (0x06) 17:24:54.425 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[FibaroVenetianBlindCCReport] position: 99 17:24:54.429 SERIAL » 0x010a001318038e0203254710 (12 bytes) 17:24:54.429 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 71 └─[MultiChannelAssociationCCGet] group id: 3 17:24:54.430 CNTRLR « [Node 026] received venetian blind state: position: 99 tilt: undefined 17:24:54.430 CNTRLR [Node 026] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 17:24:54.430 CNTRLR [Node 026] [~] [Manufacturer Proprietary] interviewCom [Endpoint 0] [internal] plete: true => true 17:24:54.431 CNTRLR [Node 026] MultiChannelAssociationCC: doing a partial interview... 17:24:54.431 CNTRLR » [Node 026] querying multi channel association group #1... 17:24:54.434 SERIAL « [ACK] (0x06) 17:24:54.437 SERIAL « 0x0104011301e8 (6 bytes) 17:24:54.438 SERIAL » [ACK] (0x06) 17:24:54.438 DRIVER « [RES] [SendData] was sent: true 17:24:54.518 SERIAL « 0x0107001347000009a5 (9 bytes) 17:24:54.519 SERIAL » [ACK] (0x06) 17:24:54.519 DRIVER « [REQ] [SendData] callback id: 71 transmit status: OK 17:24:54.533 SERIAL « 0x010b00040018058e0303050066 (13 bytes) 17:24:54.533 SERIAL » [ACK] (0x06) 17:24:54.534 CNTRLR [Node 024] [~] [Multi Channel Association] maxNodes[3]: 5 => 5 17:24:54.535 CNTRLR [Node 024] [~] [Multi Channel Association] nodeIds[3]: => 17:24:54.536 CNTRLR [Node 024] [~] [Multi Channel Association] endpoints[3]: => 17:24:54.537 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 3 maximum # of nodes: 5 node ids: endpoints: 17:24:54.540 SERIAL » 0x010a00131d038e0201254818 (12 bytes) 17:24:54.540 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 72 └─[MultiChannelAssociationCCGet] group id: 1 17:24:54.541 CNTRLR « [Node 024] received information for multi channel association group #3: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 17:24:54.541 CNTRLR » [Node 024] querying multi channel association group #4... 17:24:54.545 SERIAL « [ACK] (0x06) 17:24:54.552 SERIAL « 0x0104011301e8 (6 bytes) 17:24:54.552 SERIAL » [ACK] (0x06) 17:24:54.555 DRIVER « [RES] [SendData] was sent: true 17:24:55.995 SERIAL « 0x010700134800009132 (9 bytes) 17:24:55.995 SERIAL » [ACK] (0x06) 17:24:55.996 DRIVER « [REQ] [SendData] callback id: 72 transmit status: OK 17:24:56.076 SERIAL « 0x010e0004001d088e030101000001006c (16 bytes) 17:24:56.076 SERIAL » [ACK] (0x06) 17:24:56.078 CNTRLR [Node 029] [~] [Multi Channel Association] maxNodes[1]: 1 => 1 17:24:56.079 CNTRLR [Node 029] [~] [Multi Channel Association] nodeIds[1]: => 17:24:56.080 CNTRLR [Node 029] [~] [Multi Channel Association] endpoints[1]: [object Object] => [o bject Object] 17:24:56.081 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 1 node ids: endpoints: 1:0 17:24:56.085 SERIAL » 0x010a001303038e0202254904 (12 bytes) 17:24:56.086 DRIVER » [Node 003] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 73 └─[MultiChannelAssociationCCGet] group id: 2 17:24:56.086 CNTRLR « [Node 029] received information for multi channel association group #1: maximum # of nodes: 1 currently assigned nodes: currently assigned endpoints: 1:0 17:24:56.087 CNTRLR [Node 029] [~] [Association] hasLifeline: true => true [internal] 17:24:56.088 CNTRLR [Node 029] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:24:56.139 SERIAL « [ACK] (0x06) 17:24:56.143 SERIAL « 0x0104011301e8 (6 bytes) 17:24:56.143 SERIAL » [ACK] (0x06) 17:24:56.145 DRIVER « [RES] [SendData] was sent: true 17:24:56.148 CNTRLR [Node 029] AssociationGroupInfoCC: doing a partial interview... 17:24:56.148 CNTRLR [Node 029] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 17:24:56.149 CNTRLR [Node 029] NotificationCC: doing a partial interview... 17:24:56.149 CNTRLR » [Node 029] querying notification status for Power Management... 17:24:56.165 SERIAL « 0x0107001349000007a5 (9 bytes) 17:24:56.165 SERIAL » [ACK] (0x06) 17:24:56.166 DRIVER « [REQ] [SendData] callback id: 73 transmit status: OK 17:24:56.187 SERIAL « 0x010c00040003063105042204c622 (14 bytes) 17:24:56.188 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:24:56.189 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 135.6 => 122.2 [Endpoint 0] 17:24:56.189 SERIAL » [ACK] (0x06) 17:24:56.190 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 122.2 17:24:56.205 SERIAL « 0x010b00040003058e030205007c (13 bytes) 17:24:56.206 SERIAL » [ACK] (0x06) 17:24:56.207 CNTRLR [Node 003] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 17:24:56.208 CNTRLR [Node 003] [~] [Multi Channel Association] nodeIds[2]: => 17:24:56.209 CNTRLR [Node 003] [~] [Multi Channel Association] endpoints[2]: => 17:24:56.210 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 17:24:56.213 SERIAL » 0x010a00131a038e0201254a1d (12 bytes) 17:24:56.214 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 74 └─[MultiChannelAssociationCCGet] group id: 1 17:24:56.215 CNTRLR « [Node 003] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 17:24:56.215 CNTRLR [Node 003] [~] [Association] hasLifeline: true => true [internal] 17:24:56.215 CNTRLR [Node 003] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:24:56.216 CNTRLR [Node 003] Interview stage completed: CommandClasses 17:24:56.216 CNTRLR [Node 003] Interview stage completed: OverwriteConfig 17:24:56.216 CNTRLR » [Node 003] requesting node neighbors... 17:24:56.219 SERIAL « [ACK] (0x06) 17:24:56.222 SERIAL « 0x0104011301e8 (6 bytes) 17:24:56.222 SERIAL » [ACK] (0x06) 17:24:56.223 DRIVER « [RES] [SendData] was sent: true 17:24:56.261 SERIAL « 0x010700134a000005a4 (9 bytes) 17:24:56.261 SERIAL » [ACK] (0x06) 17:24:56.262 DRIVER « [REQ] [SendData] callback id: 74 transmit status: OK 17:24:56.358 SERIAL « 0x010b0004001a058e0301070064 (13 bytes) 17:24:56.359 SERIAL » [ACK] (0x06) 17:24:56.361 CNTRLR [Node 026] [~] [Multi Channel Association] maxNodes[1]: 7 => 7 17:24:56.362 CNTRLR [Node 026] [~] [Multi Channel Association] nodeIds[1]: => 17:24:56.363 CNTRLR [Node 026] [~] [Multi Channel Association] endpoints[1]: => 17:24:56.364 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 7 node ids: endpoints: 17:24:56.369 SERIAL » 0x01070080030000007b (9 bytes) 17:24:56.370 DRIVER » [Node 003] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:24:56.370 CNTRLR « [Node 026] received information for multi channel association group #1: maximum # of nodes: 7 currently assigned nodes: currently assigned endpoints: 17:24:56.371 CNTRLR » [Node 026] querying multi channel association group #2... 17:24:56.382 SERIAL « [ACK] (0x06) 17:24:56.383 SERIAL « 0x01200180c1fffd6f0700000000000000000000000000000000000000000000000 (34 bytes) 0f5 17:24:56.384 SERIAL » [ACK] (0x06) 17:24:56.386 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 19, 20, 21, 22, 23, 24 , 25, 26, 27, 28, 30, 31, 33, 34, 35 17:24:56.391 SERIAL » 0x010a001318038e0204254b1b (12 bytes) 17:24:56.392 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 75 └─[MultiChannelAssociationCCGet] group id: 4 17:24:56.392 CNTRLR « [Node 003] node neighbors received: 1, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 30, 31, 33, 34, 35 17:24:56.392 CNTRLR [Node 003] Interview stage completed: Neighbors 17:24:56.392 CNTRLR [Node 003] Interview completed 17:24:56.397 SERIAL « [ACK] (0x06) 17:24:56.400 SERIAL « 0x0104011301e8 (6 bytes) 17:24:56.401 SERIAL » [ACK] (0x06) 17:24:56.403 DRIVER « [RES] [SendData] was sent: true 17:24:56.420 SERIAL « 0x010700134b000003a3 (9 bytes) 17:24:56.421 SERIAL » [ACK] (0x06) 17:24:56.421 DRIVER « [REQ] [SendData] callback id: 75 transmit status: OK 17:24:56.435 SERIAL « 0x010b00040018058e0304050061 (13 bytes) 17:24:56.435 SERIAL » [ACK] (0x06) 17:24:56.436 CNTRLR [Node 024] [~] [Multi Channel Association] maxNodes[4]: 5 => 5 17:24:56.437 CNTRLR [Node 024] [~] [Multi Channel Association] nodeIds[4]: => 17:24:56.438 CNTRLR [Node 024] [~] [Multi Channel Association] endpoints[4]: => 17:24:56.440 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 4 maximum # of nodes: 5 node ids: endpoints: 17:24:56.443 SERIAL » 0x010a00131a038e0202254c18 (12 bytes) 17:24:56.444 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 76 └─[MultiChannelAssociationCCGet] group id: 2 17:24:56.444 CNTRLR « [Node 024] received information for multi channel association group #4: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 17:24:56.445 CNTRLR » [Node 024] querying multi channel association group #5... 17:24:56.448 SERIAL « [ACK] (0x06) 17:24:56.452 SERIAL « 0x0104011301e8 (6 bytes) 17:24:56.452 SERIAL » [ACK] (0x06) 17:24:56.453 DRIVER « [RES] [SendData] was sent: true 17:24:56.491 SERIAL « 0x010700134c000005a2 (9 bytes) 17:24:56.491 SERIAL » [ACK] (0x06) 17:24:56.492 DRIVER « [REQ] [SendData] callback id: 76 transmit status: OK 17:24:56.539 SERIAL « 0x010b0004001a058e0302070067 (13 bytes) 17:24:56.539 SERIAL » [ACK] (0x06) 17:24:56.540 CNTRLR [Node 026] [~] [Multi Channel Association] maxNodes[2]: 7 => 7 17:24:56.541 CNTRLR [Node 026] [~] [Multi Channel Association] nodeIds[2]: => 17:24:56.542 CNTRLR [Node 026] [~] [Multi Channel Association] endpoints[2]: => 17:24:56.543 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 7 node ids: endpoints: 17:24:56.546 SERIAL » 0x010a001318038e0205254d1c (12 bytes) 17:24:56.546 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 77 └─[MultiChannelAssociationCCGet] group id: 5 17:24:56.547 CNTRLR « [Node 026] received information for multi channel association group #2: maximum # of nodes: 7 currently assigned nodes: currently assigned endpoints: 17:24:56.547 CNTRLR » [Node 026] querying additional non-multi-channel association groups... 17:24:56.547 CNTRLR » [Node 026] querying association group #3... 17:24:56.551 SERIAL « [ACK] (0x06) 17:24:56.555 SERIAL « 0x0104011301e8 (6 bytes) 17:24:56.555 SERIAL » [ACK] (0x06) 17:24:56.557 DRIVER « [RES] [SendData] was sent: true 17:24:56.629 SERIAL « 0x010700134d000007a1 (9 bytes) 17:24:56.629 SERIAL » [ACK] (0x06) 17:24:56.630 DRIVER « [REQ] [SendData] callback id: 77 transmit status: OK 17:24:56.642 SERIAL « 0x010b00040018058e0305050060 (13 bytes) 17:24:56.643 SERIAL » [ACK] (0x06) 17:24:56.644 CNTRLR [Node 024] [~] [Multi Channel Association] maxNodes[5]: 5 => 5 17:24:56.645 CNTRLR [Node 024] [~] [Multi Channel Association] nodeIds[5]: => 17:24:56.645 CNTRLR [Node 024] [~] [Multi Channel Association] endpoints[5]: => 17:24:56.646 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 5 maximum # of nodes: 5 node ids: endpoints: 17:24:56.656 SERIAL » 0x010a00131a03850203254e10 (12 bytes) 17:24:56.657 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 78 └─[AssociationCCGet] group id: 3 17:24:56.657 CNTRLR « [Node 024] received information for multi channel association group #5: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 17:24:56.658 CNTRLR [Node 024] [~] [Association] hasLifeline: true => true [internal] 17:24:56.658 CNTRLR [Node 024] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:24:56.659 CNTRLR [Node 024] AssociationGroupInfoCC: doing a partial interview... 17:24:56.659 CNTRLR [Node 024] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 17:24:56.660 CNTRLR [Node 024] CentralSceneCC: doing a partial interview... 17:24:56.661 CNTRLR [Node 024] [~] [Central Scene] interviewComplete: true [Endpoint 0] [internal] => true 17:24:56.661 CNTRLR [Node 024] NotificationCC: doing a partial interview... 17:24:56.662 CNTRLR [Node 024] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 17:24:56.662 CNTRLR [Node 024] Interview stage completed: CommandClasses 17:24:56.662 CNTRLR [Node 024] Interview stage completed: OverwriteConfig 17:24:56.662 CNTRLR » [Node 024] requesting node neighbors... 17:24:56.666 SERIAL « [ACK] (0x06) 17:24:56.667 SERIAL « 0x0104011301e8 (6 bytes) 17:24:56.667 SERIAL » [ACK] (0x06) 17:24:56.668 DRIVER « [RES] [SendData] was sent: true 17:24:56.704 SERIAL « 0x010700134e000004a1 (9 bytes) 17:24:56.704 SERIAL » [ACK] (0x06) 17:24:56.705 DRIVER « [REQ] [SendData] callback id: 78 transmit status: OK 17:24:56.753 SERIAL « 0x010c0004001a068503030100016e (14 bytes) 17:24:56.754 SERIAL » [ACK] (0x06) 17:24:56.754 CNTRLR [Node 026] [~] [Association] maxNodes[3]: 1 => 1 [internal] 17:24:56.755 CNTRLR [Node 026] [~] [Association] nodeIds[3]: 1 => 1 [internal] 17:24:56.755 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 17:24:56.758 SERIAL » 0x010700801800000060 (9 bytes) 17:24:56.759 DRIVER » [Node 024] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:24:56.759 CNTRLR « [Node 026] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 17:24:56.759 CNTRLR [Node 026] [~] [Association] hasLifeline: true => true [internal] 17:24:56.760 CNTRLR [Node 026] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:24:56.760 CNTRLR [Node 026] Interview stage completed: CommandClasses 17:24:56.760 CNTRLR [Node 026] Interview stage completed: OverwriteConfig 17:24:56.760 CNTRLR » [Node 026] requesting node neighbors... 17:24:56.762 SERIAL « [ACK] (0x06) 17:24:56.763 SERIAL « 0x0120018065f96c6f0700000000000000000000000000000000000000000000000 (34 bytes) 0c6 17:24:56.764 SERIAL » [ACK] (0x06) 17:24:56.764 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 9, 12, 13, 14, 15, 16, 19, 20, 22, 23, 25, 26, 27, 28, 30, 31, 33, 34, 35 17:24:56.775 SERIAL » 0x010700801a00000062 (9 bytes) 17:24:56.776 DRIVER » [Node 026] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:24:56.776 CNTRLR « [Node 024] node neighbors received: 1, 3, 6, 7, 9, 12, 13, 14, 15, 16, 19, 2 0, 22, 23, 25, 26, 27, 28, 30, 31, 33, 34, 35 17:24:56.776 CNTRLR [Node 024] Interview stage completed: Neighbors 17:24:56.776 CNTRLR [Node 024] Interview completed 17:24:57.060 SERIAL « [ACK] (0x06) 17:24:57.061 SERIAL « 0x012001806579ec7d0300000000000000000000000000000000000000000000000 (34 bytes) 0d0 17:24:57.062 SERIAL » [ACK] (0x06) 17:24:57.062 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 9, 12, 13, 14, 15, 19, 20, 22, 23, 24, 25, 27, 28, 29, 30, 31, 33, 34 17:24:57.067 SERIAL » 0x0109001321026007254fcb (11 bytes) 17:24:57.067 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 79 └─[MultiChannelCCEndPointGet] 17:24:57.067 CNTRLR « [Node 026] node neighbors received: 1, 3, 6, 7, 9, 12, 13, 14, 15, 19, 20, 2 2, 23, 24, 25, 27, 28, 29, 30, 31, 33, 34 17:24:57.068 CNTRLR [Node 026] Interview stage completed: Neighbors 17:24:57.070 CNTRLR [Node 026] Interview completed 17:24:57.073 SERIAL « [ACK] (0x06) 17:24:57.075 SERIAL « 0x0104011301e8 (6 bytes) 17:24:57.075 SERIAL » [ACK] (0x06) 17:24:57.076 DRIVER « [RES] [SendData] was sent: true 17:24:57.092 SERIAL « 0x010700134f000002a6 (9 bytes) 17:24:57.093 SERIAL » [ACK] (0x06) 17:24:57.093 DRIVER « [REQ] [SendData] callback id: 79 transmit status: OK 17:24:57.102 SERIAL « 0x010a000400210460084005f9 (12 bytes) 17:24:57.103 CNTRLR [Node 033] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 17:24:57.103 CNTRLR [Node 033] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 17:24:57.104 CNTRLR [Node 033] [~] [Multi Channel] individualCount: 5 => 5 [Endpoint 0] [internal] 17:24:57.104 SERIAL » [ACK] (0x06) 17:24:57.105 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 5 count is dynamic: false identical capabilities: true 17:24:57.108 SERIAL » 0x01090013220260072550d7 (11 bytes) 17:24:57.108 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 80 └─[MultiChannelCCEndPointGet] 17:24:57.109 CNTRLR [Node 033] The node is alive. 17:24:57.109 CNTRLR [Node 033] The node is ready to be used 17:24:57.110 CNTRLR « [Node 033] received response for device endpoints: endpoint count (individual): 5 count is dynamic: false identical capabilities: true 17:24:57.111 CNTRLR » [Node 033] querying all endpoints... 17:24:57.115 SERIAL « [ACK] (0x06) 17:24:57.118 SERIAL « 0x0104011301e8 (6 bytes) 17:24:57.119 SERIAL » [ACK] (0x06) 17:24:57.120 DRIVER « [RES] [SendData] was sent: true 17:24:57.138 SERIAL « 0x0107001350000002b9 (9 bytes) 17:24:57.138 SERIAL » [ACK] (0x06) 17:24:57.139 DRIVER « [REQ] [SendData] callback id: 80 transmit status: OK 17:24:57.152 SERIAL « 0x010b00040022056008400200fd (13 bytes) 17:24:57.153 CNTRLR [Node 034] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 17:24:57.154 CNTRLR [Node 034] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true => true 17:24:57.154 CNTRLR [Node 034] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 17:24:57.154 CNTRLR [Node 034] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 17:24:57.154 SERIAL » [ACK] (0x06) 17:24:57.155 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: true endpoint count (aggregated): 0 17:24:57.158 SERIAL » 0x010a00131f037005012551fa (12 bytes) 17:24:57.159 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 81 └─[ConfigurationCCGet] parameter #: 1 17:24:57.159 CNTRLR [Node 034] The node is alive. 17:24:57.160 CNTRLR [Node 034] The node is ready to be used 17:24:57.161 CNTRLR « [Node 034] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: true endpoint count (aggregated): 0 17:24:57.161 CNTRLR » [Node 034] querying all endpoints... 17:24:57.168 SERIAL « [ACK] (0x06) 17:24:57.170 SERIAL « 0x0104011301e8 (6 bytes) 17:24:57.171 SERIAL » [ACK] (0x06) 17:24:57.470 DRIVER « [RES] [SendData] was sent: true 17:24:57.475 SERIAL « 0x0107001351000002b8 (9 bytes) 17:24:57.475 SERIAL » [ACK] (0x06) 17:24:57.476 DRIVER « [REQ] [SendData] callback id: 81 transmit status: OK 17:24:57.484 SERIAL « 0x010b0004001f0570060101ff63 (13 bytes) 17:24:57.489 CNTRLR [Node 031] [~] [Configuration] 1: 255 => 255 17:24:57.490 SERIAL » [ACK] (0x06) 17:24:57.491 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 255 17:24:57.494 SERIAL » 0x01090013230260072552d4 (11 bytes) 17:24:57.495 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 82 └─[MultiChannelCCEndPointGet] 17:24:57.495 CNTRLR « [Node 031] parameter #1 has value: 255 17:24:57.496 CNTRLR » [Node 031] querying parameter #3 value... 17:24:57.500 SERIAL « [ACK] (0x06) 17:24:57.503 SERIAL « 0x0104011301e8 (6 bytes) 17:24:57.504 SERIAL » [ACK] (0x06) 17:24:57.504 DRIVER « [RES] [SendData] was sent: true 17:24:58.857 SERIAL « 0x010700135200008831 (9 bytes) 17:24:58.858 SERIAL » [ACK] (0x06) 17:24:58.858 DRIVER « [REQ] [SendData] callback id: 82 transmit status: OK 17:24:58.937 SERIAL « 0x010b00040023056008000200bc (13 bytes) 17:24:58.938 CNTRLR [Node 035] [~] [Multi Channel] countIsDynamic: false = [Endpoint 0] [internal] > false 17:24:58.939 CNTRLR [Node 035] [~] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] false => false 17:24:58.939 CNTRLR [Node 035] [~] [Multi Channel] individualCount: 2 => 2 [Endpoint 0] [internal] 17:24:58.939 CNTRLR [Node 035] [~] [Multi Channel] aggregatedCount: 0 => 0 [Endpoint 0] [internal] 17:24:58.940 SERIAL » [ACK] (0x06) 17:24:58.942 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 17:24:58.950 SERIAL » 0x010900130602984025534f (11 bytes) 17:24:58.950 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 83 └─[SecurityCCNonceGet] 17:24:58.951 CNTRLR [Node 035] The node is alive. 17:24:58.951 CNTRLR [Node 035] The node is ready to be used 17:24:58.952 CNTRLR « [Node 035] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: false endpoint count (aggregated): 0 17:24:58.953 CNTRLR » [Node 035] querying all endpoints... 17:24:58.964 SERIAL « [ACK] (0x06) 17:24:58.965 SERIAL « 0x0104011301e8 (6 bytes) 17:24:58.965 SERIAL » [ACK] (0x06) 17:24:58.967 DRIVER « [RES] [SendData] was sent: true 17:25:00.362 SERIAL « 0x010700135300008d35 (9 bytes) 17:25:00.363 SERIAL » [ACK] (0x06) 17:25:00.364 DRIVER « [REQ] [SendData] callback id: 83 transmit status: OK 17:25:00.443 SERIAL « 0x0110000400060a988013ae71ecd8f0da765b (18 bytes) 17:25:00.445 SERIAL » [ACK] (0x06) 17:25:00.447 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x13ae71ecd8f0da76 17:25:00.456 SERIAL » 0x0120001306199881e800328f5130ae46e398825c9ec513bcf27cdd35d00b4e255 (34 bytes) 4c5 17:25:00.457 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 84 └─[SecurityCCCommandEncapsulation] │ nonce id: 19 └─[NotificationCCGet] notification type: Power Management 17:25:00.460 SERIAL « [ACK] (0x06) 17:25:00.468 SERIAL « 0x0104011301e8 (6 bytes) 17:25:00.469 SERIAL » [ACK] (0x06) 17:25:00.470 DRIVER « [RES] [SendData] was sent: true 17:25:00.589 SERIAL « 0x010700135400000cb3 (9 bytes) 17:25:00.589 SERIAL » [ACK] (0x06) 17:25:00.590 DRIVER « [REQ] [SendData] callback id: 84 transmit status: OK 17:25:00.669 SERIAL « 0x0108000400060298402f (10 bytes) 17:25:00.671 SERIAL » [ACK] (0x06) 17:25:00.672 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:25:00.683 SERIAL » 0x01110013060a98804944abafbe11dad1055514 (19 bytes) 17:25:00.684 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 85 └─[SecurityCCNonceReport] nonce: 0x4944abafbe11dad1 17:25:00.688 SERIAL « [ACK] (0x06) 17:25:00.693 SERIAL « 0x0104011301e8 (6 bytes) 17:25:00.694 SERIAL » [ACK] (0x06) 17:25:00.695 DRIVER « [RES] [SendData] was sent: true 17:25:00.803 SERIAL « 0x010700135500000bb5 (9 bytes) 17:25:00.803 SERIAL » [ACK] (0x06) 17:25:00.804 DRIVER « [REQ] [SendData] callback id: 85 transmit status: OK 17:25:00.903 SERIAL « 0x0123000400061d988132f29b1d18d655a94c998c0b1cecb3a9158049bc61cbf4f (37 bytes) 2c06893e1 17:25:00.905 SERIAL » [ACK] (0x06) 17:25:00.908 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 17:25:00.914 SERIAL » 0x010c00131d0571040008002556f6 (14 bytes) 17:25:00.914 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 86 └─[NotificationCCGet] notification type: Power Management 17:25:00.916 CNTRLR [Node 006] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 0] 54 17:25:00.917 CNTRLR » [Node 006] querying notification status for System... 17:25:00.923 SERIAL « [ACK] (0x06) 17:25:00.925 SERIAL « 0x0104011301e8 (6 bytes) 17:25:00.926 SERIAL » [ACK] (0x06) 17:25:00.926 DRIVER « [RES] [SendData] was sent: true 17:25:02.470 SERIAL « 0x010700135600009b26 (9 bytes) 17:25:02.471 SERIAL » [ACK] (0x06) 17:25:02.477 DRIVER « [REQ] [SendData] callback id: 86 transmit status: OK 17:25:02.554 SERIAL « 0x010f0004001d097105000000ff08fe009d (17 bytes) 17:25:02.555 SERIAL » [ACK] (0x06) 17:25:02.557 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 17:25:02.560 SERIAL » 0x010b00132104600bffff2557db (13 bytes) 17:25:02.561 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 87 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 17:25:02.562 CNTRLR [Node 029] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 0] 54 17:25:02.562 CNTRLR » [Node 029] querying notification status for System... 17:25:02.566 SERIAL « [ACK] (0x06) 17:25:02.570 SERIAL « 0x0104011301e8 (6 bytes) 17:25:02.570 SERIAL » [ACK] (0x06) 17:25:02.571 DRIVER « [RES] [SendData] was sent: true 17:25:02.624 SERIAL « 0x01080004001102840763 (10 bytes) 17:25:02.624 SERIAL » [ACK] (0x06) 17:25:02.625 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:25:02.626 CNTRLR « [Node 017] received wakeup notification 17:25:02.627 CNTRLR [Node 017] The node is now awake. 17:25:02.655 SERIAL « 0x0107001357000009b5 (9 bytes) 17:25:02.655 SERIAL » [ACK] (0x06) 17:25:02.655 DRIVER « [REQ] [SendData] callback id: 87 transmit status: OK 17:25:02.665 SERIAL « 0x010c0004002106600c00ffff00bc (14 bytes) 17:25:02.666 SERIAL » [ACK] (0x06) 17:25:02.666 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: # of reports to follow: 0 17:25:02.670 SERIAL » 0x010b00132204600bffff2558d7 (13 bytes) 17:25:02.670 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 88 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 17:25:02.671 CNTRLR « [Node 033] Endpoint query returned no results, assuming that endpoints are seq uential 17:25:02.671 CNTRLR » [Node 033] querying capabilities for endpoint #1... 17:25:02.674 SERIAL « [ACK] (0x06) 17:25:02.678 SERIAL « 0x0104011301e8 (6 bytes) 17:25:02.679 SERIAL » [ACK] (0x06) 17:25:02.679 DRIVER « [RES] [SendData] was sent: true 17:25:02.699 SERIAL « 0x0107001358000003b0 (9 bytes) 17:25:02.699 SERIAL » [ACK] (0x06) 17:25:02.700 DRIVER « [REQ] [SendData] callback id: 88 transmit status: OK 17:25:02.714 SERIAL « 0x010d0004002207600c00ffff0102bc (15 bytes) 17:25:02.716 SERIAL » [ACK] (0x06) 17:25:02.717 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 17:25:02.722 SERIAL » 0x010a00131f037005032559f0 (12 bytes) 17:25:02.723 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 89 └─[ConfigurationCCGet] parameter #: 3 17:25:02.723 CNTRLR « [Node 034] received endpoints: 1, 2 17:25:02.723 CNTRLR » [Node 034] querying capabilities for endpoint #1... 17:25:02.727 SERIAL « [ACK] (0x06) 17:25:02.731 SERIAL « 0x0104011301e8 (6 bytes) 17:25:02.731 SERIAL » [ACK] (0x06) 17:25:02.732 DRIVER « [RES] [SendData] was sent: true 17:25:02.748 SERIAL « 0x0107001359000003b1 (9 bytes) 17:25:02.749 SERIAL » [ACK] (0x06) 17:25:02.750 DRIVER « [REQ] [SendData] callback id: 89 transmit status: OK 17:25:02.759 SERIAL « 0x010b0004001f0570060301009e (13 bytes) 17:25:02.765 CNTRLR [Node 031] [~] [Configuration] 3: 0 => 0 17:25:02.766 SERIAL » [ACK] (0x06) 17:25:02.767 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 0 17:25:02.770 SERIAL » 0x010b00132304600bffff255ad4 (13 bytes) 17:25:02.771 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 90 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 17:25:02.771 CNTRLR « [Node 031] parameter #3 has value: 0 17:25:02.772 CNTRLR » [Node 031] querying parameter #4 value... 17:25:02.775 SERIAL « [ACK] (0x06) 17:25:02.779 SERIAL « 0x0104011301e8 (6 bytes) 17:25:02.779 SERIAL » [ACK] (0x06) 17:25:02.780 DRIVER « [RES] [SendData] was sent: true 17:25:04.206 SERIAL « 0x010700135a00008f3e (9 bytes) 17:25:04.206 SERIAL » [ACK] (0x06) 17:25:04.208 DRIVER « [REQ] [SendData] callback id: 90 transmit status: OK 17:25:04.288 SERIAL « 0x010d0004002307600c00ffff0102bd (15 bytes) 17:25:04.289 SERIAL » [ACK] (0x06) 17:25:04.291 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 17:25:04.301 SERIAL » 0x0109001306029840255b47 (11 bytes) 17:25:04.302 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 91 └─[SecurityCCNonceGet] 17:25:04.303 CNTRLR « [Node 035] received endpoints: 1, 2 17:25:04.303 CNTRLR » [Node 035] querying capabilities for endpoint #1... 17:25:04.309 SERIAL « [ACK] (0x06) 17:25:04.311 SERIAL « 0x0104011301e8 (6 bytes) 17:25:04.312 SERIAL » [ACK] (0x06) 17:25:04.313 DRIVER « [RES] [SendData] was sent: true 17:25:05.800 SERIAL « 0x010700135b00009626 (9 bytes) 17:25:05.800 SERIAL » [ACK] (0x06) 17:25:05.802 DRIVER « [REQ] [SendData] callback id: 91 transmit status: OK 17:25:05.883 SERIAL « 0x0110000400060a9880866461f19b4ebfef08 (18 bytes) 17:25:05.884 SERIAL » [ACK] (0x06) 17:25:05.885 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x866461f19b4ebfef 17:25:05.891 SERIAL » 0x0120001306199881af45107e7017f1aa7c29184d039d867b4cf6cdcef21f52255 (34 bytes) c6e 17:25:05.892 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 92 └─[SecurityCCCommandEncapsulation] │ nonce id: 134 └─[NotificationCCGet] notification type: System 17:25:05.895 SERIAL « [ACK] (0x06) 17:25:05.903 SERIAL « 0x0104011301e8 (6 bytes) 17:25:05.903 SERIAL » [ACK] (0x06) 17:25:05.904 DRIVER « [RES] [SendData] was sent: true 17:25:05.943 SERIAL « 0x010c0004000306310504220951b8 (14 bytes) 17:25:05.945 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:25:05.946 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 122.2 => 238.5 [Endpoint 0] 17:25:05.947 SERIAL » [ACK] (0x06) 17:25:05.948 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 238.5 17:25:06.036 SERIAL « 0x010700135c00000eb9 (9 bytes) 17:25:06.037 SERIAL » [ACK] (0x06) 17:25:06.038 DRIVER « [REQ] [SendData] callback id: 92 transmit status: OK 17:25:06.119 SERIAL « 0x0108000400060298402f (10 bytes) 17:25:06.120 SERIAL » [ACK] (0x06) 17:25:06.121 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:25:06.138 SERIAL » 0x01110013060a988088af6511c8e4c04a055d44 (19 bytes) 17:25:06.139 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 93 └─[SecurityCCNonceReport] nonce: 0x88af6511c8e4c04a 17:25:06.141 SERIAL « [ACK] (0x06) 17:25:06.147 SERIAL « 0x0104011301e8 (6 bytes) 17:25:06.148 SERIAL » [ACK] (0x06) 17:25:06.149 DRIVER « [RES] [SendData] was sent: true 17:25:06.253 SERIAL « 0x010700135d00000bbd (9 bytes) 17:25:06.254 SERIAL » [ACK] (0x06) 17:25:06.255 DRIVER « [REQ] [SendData] callback id: 93 transmit status: OK 17:25:06.353 SERIAL « 0x0123000400061d9881ed88718921a5ab8bf56639f6cbca3a838e1588b1d79140b (37 bytes) 2b2697bb1 17:25:06.355 SERIAL » [ACK] (0x06) 17:25:06.357 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[NotificationCCReport] notification type: System notification status: 255 notification event: Unknown (0xfe) 17:25:06.364 SERIAL » 0x010c00131d057104000900255eff (14 bytes) 17:25:06.365 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 94 └─[NotificationCCGet] notification type: System 17:25:06.366 CNTRLR [Node 006] [~] [Notification] System[unknown]: 254 => 254 [Endpoint 0] 17:25:06.367 CNTRLR [Node 006] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 17:25:06.431 SERIAL « [ACK] (0x06) 17:25:06.434 SERIAL « 0x0104011301e8 (6 bytes) 17:25:06.435 SERIAL » [ACK] (0x06) 17:25:06.435 DRIVER « [RES] [SendData] was sent: true 17:25:06.438 CNTRLR [Node 006] Interview stage completed: CommandClasses 17:25:06.438 CNTRLR [Node 006] Interview stage completed: OverwriteConfig 17:25:06.438 CNTRLR » [Node 006] requesting node neighbors... 17:25:07.931 SERIAL « 0x010700135e00009c29 (9 bytes) 17:25:07.931 SERIAL » [ACK] (0x06) 17:25:07.932 DRIVER « [REQ] [SendData] callback id: 94 transmit status: OK 17:25:08.012 SERIAL « 0x010f0004001d097105000000ff09fe009c (17 bytes) 17:25:08.013 SERIAL » [ACK] (0x06) 17:25:08.015 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: System notification status: 255 notification event: Unknown (0xfe) 17:25:08.022 SERIAL » 0x01070080060000007e (9 bytes) 17:25:08.023 DRIVER » [Node 006] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:25:08.025 CNTRLR [Node 029] [~] [Notification] System[unknown]: 254 => 254 [Endpoint 0] 17:25:08.026 CNTRLR [Node 029] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 17:25:08.062 SERIAL « [ACK] (0x06) 17:25:08.064 SERIAL « 0x0120018041ebe46b0300000000000000000000000000000000000000000000000 (34 bytes) 078 17:25:08.064 SERIAL » [ACK] (0x06) 17:25:08.073 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 7, 9, 10, 12, 14, 15, 16, 19, 22, 23, 24, 25, 26, 28, 30, 31, 3 3, 34 17:25:08.080 SERIAL » 0x010a00132103600901255fd6 (12 bytes) 17:25:08.081 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 95 └─[MultiChannelCCCapabilityGet] endpoint: 1 17:25:08.082 CNTRLR « [Node 006] node neighbors received: 1, 7, 9, 10, 12, 14, 15, 16, 19, 22, 23, 24, 25, 26, 28, 30, 31, 33, 34 17:25:08.084 CNTRLR [Node 006] Interview stage completed: Neighbors 17:25:08.085 CNTRLR [Node 006] Interview completed 17:25:08.088 CNTRLR [Node 029] Interview stage completed: CommandClasses 17:25:08.089 CNTRLR [Node 029] Interview stage completed: OverwriteConfig 17:25:08.089 CNTRLR » [Node 029] requesting node neighbors... 17:25:08.092 SERIAL « [ACK] (0x06) 17:25:08.093 SERIAL « 0x0104011301e8 (6 bytes) 17:25:08.094 SERIAL » [ACK] (0x06) 17:25:08.095 DRIVER « [RES] [SendData] was sent: true 17:25:08.108 SERIAL « 0x010700135f000002b6 (9 bytes) 17:25:08.108 SERIAL » [ACK] (0x06) 17:25:08.109 DRIVER « [REQ] [SendData] callback id: 95 transmit status: OK 17:25:08.119 SERIAL « 0x010c0004002106600a011101268d (14 bytes) 17:25:08.120 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 1] [internal] 8 17:25:08.121 SERIAL » [ACK] (0x06) 17:25:08.122 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Multilevel Switch specific device class: Multilevel Power Switch is dynamic end point: false supported CCs: · Multilevel Switch 17:25:08.127 SERIAL » 0x010700801d00000065 (9 bytes) 17:25:08.129 DRIVER » [Node 029] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:25:08.130 CNTRLR « [Node 033] received response for endpoint capabilities (#1): generic device class: Multilevel Switch specific device class: Multilevel Power Switch is dynamic end point: false supported CCs: · Multilevel Switch 17:25:08.131 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #2. .. 17:25:08.131 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 2] [internal] 8 17:25:08.132 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #3. .. 17:25:08.132 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 3] [internal] 8 17:25:08.132 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #4. .. 17:25:08.133 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 4] [internal] 8 17:25:08.133 CNTRLR [Node 033] all endpoints idendical, skipping capability query for endpoint #5. .. 17:25:08.133 CNTRLR [Node 033] [~] [Multi Channel] commandClasses: 38 => 3 [Endpoint 5] [internal] 8 17:25:08.134 CNTRLR [Node 033] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 17:25:08.135 CNTRLR [Node 033] AssociationCC: doing a partial interview... 17:25:08.135 CNTRLR » [Node 033] querying association group #1... 17:25:08.140 SERIAL « [ACK] (0x06) 17:25:08.141 SERIAL « 0x012001800030600b0600000000000000000000000000000000000000000000000 (34 bytes) 003 17:25:08.142 SERIAL » [ACK] (0x06) 17:25:08.143 DRIVER « [RES] [GetRoutingInfo] node ids: 13, 14, 22, 23, 25, 26, 28, 34, 35 17:25:08.149 SERIAL » 0x010a001322036009012560ea (12 bytes) 17:25:08.150 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 96 └─[MultiChannelCCCapabilityGet] endpoint: 1 17:25:08.151 CNTRLR « [Node 029] node neighbors received: 13, 14, 22, 23, 25, 26, 28, 34, 35 17:25:08.151 CNTRLR [Node 029] Interview stage completed: Neighbors 17:25:08.152 CNTRLR [Node 029] Interview completed 17:25:08.156 SERIAL « [ACK] (0x06) 17:25:08.158 SERIAL « 0x0104011301e8 (6 bytes) 17:25:08.159 SERIAL » [ACK] (0x06) 17:25:08.160 DRIVER « [RES] [SendData] was sent: true 17:25:08.179 SERIAL « 0x010700136000000388 (9 bytes) 17:25:08.179 SERIAL » [ACK] (0x06) 17:25:08.189 DRIVER « [REQ] [SendData] callback id: 96 transmit status: OK 17:25:08.201 SERIAL « 0x0114000400220e600a0110015e862585598e32ef26ed (22 bytes) 17:25:08.202 CNTRLR [Node 034] [~] [Multi Channel] commandClasses: 94,134, [Endpoint 1] [internal] 37,133,89,142,50 => 94,134,37,133,89,142,50 17:25:08.202 SERIAL » [ACK] (0x06) 17:25:08.203 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Z-Wave Plus Info · Version · Binary Switch · Association · Association Group Information · Multi Channel Association · Meter 17:25:08.207 SERIAL » 0x010a00131f037005042561cf (12 bytes) 17:25:08.208 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 97 └─[ConfigurationCCGet] parameter #: 4 17:25:08.209 CNTRLR « [Node 034] received response for endpoint capabilities (#1): generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Z-Wave Plus Info · Version · Binary Switch · Association · Association Group Information · Multi Channel Association · Meter 17:25:08.209 CNTRLR [Node 034] all endpoints idendical, skipping capability query for endpoint #2. .. 17:25:08.209 CNTRLR [Node 034] [~] [Multi Channel] commandClasses: 94,134, [Endpoint 2] [internal] 37,133,89,142,50 => 94,134,37,133,89,142,50 17:25:08.210 CNTRLR [Node 034] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 17:25:08.213 CNTRLR [Node 034] ZWavePlusCC: doing a partial interview... [Endpoint 1] 17:25:08.213 CNTRLR [Node 034] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 17:25:08.214 CNTRLR [Node 034] BinarySwitchCC: doing a partial interview... [Endpoint 1] 17:25:08.214 CNTRLR » [Node 034] querying Binary Switch state... [Endpoint 1] 17:25:08.219 SERIAL « [ACK] (0x06) 17:25:08.220 SERIAL « 0x0104011301e8 (6 bytes) 17:25:08.220 SERIAL » [ACK] (0x06) 17:25:08.221 DRIVER « [RES] [SendData] was sent: true 17:25:08.234 SERIAL « 0x010700136100000288 (9 bytes) 17:25:08.235 SERIAL » [ACK] (0x06) 17:25:08.236 DRIVER « [REQ] [SendData] callback id: 97 transmit status: OK 17:25:08.245 SERIAL « 0x010c0004001f067006040200009e (14 bytes) 17:25:08.250 CNTRLR [Node 031] [~] [Configuration] 4: 0 => 0 17:25:08.251 SERIAL » [ACK] (0x06) 17:25:08.253 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 2 value: 0 17:25:08.257 SERIAL » 0x010a001323036009012562e9 (12 bytes) 17:25:08.258 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 98 └─[MultiChannelCCCapabilityGet] endpoint: 1 17:25:08.259 CNTRLR « [Node 031] parameter #4 has value: 0 17:25:08.260 CNTRLR » [Node 031] querying parameter #5 value... 17:25:08.264 SERIAL « [ACK] (0x06) 17:25:08.267 SERIAL « 0x0104011301e8 (6 bytes) 17:25:08.267 SERIAL » [ACK] (0x06) 17:25:08.268 DRIVER « [RES] [SendData] was sent: true 17:25:09.621 SERIAL « 0x010700136200008801 (9 bytes) 17:25:09.622 SERIAL » [ACK] (0x06) 17:25:09.623 DRIVER « [REQ] [SendData] callback id: 98 transmit status: OK 17:25:09.709 SERIAL « 0x011a0004002314600a0108065e8e404353989f596c717580818522a3 (28 bytes) 17:25:09.710 CNTRLR [Node 035] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 1] [internal] 64,67,83,152,159,89,108,113,117,128,129,133,34 => 94,142,64,67,83,152,159,89,1 08,113,117,128,129,133,34 17:25:09.711 SERIAL » [ACK] (0x06) 17:25:09.712 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 17:25:09.719 SERIAL » 0x010a00132103850201256304 (12 bytes) 17:25:09.720 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 99 └─[AssociationCCGet] group id: 1 17:25:09.721 CNTRLR « [Node 035] received response for endpoint capabilities (#1): generic device class: Thermostat specific device class: Thermostat General V2 is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Thermostat Mode · Thermostat Setpoint · Schedule · Security · Security 2 · Association Group Information · Supervision · Notification · Protection · Battery · Clock · Association · Application Status 17:25:09.721 CNTRLR » [Node 035] querying capabilities for endpoint #2... 17:25:09.727 SERIAL « [ACK] (0x06) 17:25:09.729 SERIAL « 0x0104011301e8 (6 bytes) 17:25:09.730 SERIAL » [ACK] (0x06) 17:25:09.731 DRIVER « [RES] [SendData] was sent: true 17:25:09.805 SERIAL « 0x010700136300000880 (9 bytes) 17:25:09.806 SERIAL » [ACK] (0x06) 17:25:09.807 DRIVER « [REQ] [SendData] callback id: 99 transmit status: OK 17:25:09.816 SERIAL « 0x010b0004002105850301050056 (13 bytes) 17:25:09.817 SERIAL » [ACK] (0x06) 17:25:09.818 CNTRLR [Node 033] [~] [Association] maxNodes[1]: 5 => 5 [internal] 17:25:09.819 CNTRLR [Node 033] [~] [Association] nodeIds[1]: => [internal] 17:25:09.820 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 1 max # of nodes: 5 node IDs: reports to follow: 0 17:25:09.825 SERIAL » 0x010d00132206600d000125022564cf (15 bytes) 17:25:09.826 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 100 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 17:25:09.827 CNTRLR « [Node 033] received information for association group #1: maximum # of nodes: 5 currently assigned nodes: 17:25:09.827 CNTRLR » [Node 033] querying association group #2... 17:25:09.832 SERIAL « [ACK] (0x06) 17:25:09.835 SERIAL « 0x0104011301e8 (6 bytes) 17:25:09.835 SERIAL » [ACK] (0x06) 17:25:09.836 DRIVER « [RES] [SendData] was sent: true 17:25:09.856 SERIAL « 0x01070013640000028d (9 bytes) 17:25:09.857 SERIAL » [ACK] (0x06) 17:25:09.858 DRIVER « [REQ] [SendData] callback id: 100 transmit status: OK 17:25:09.872 SERIAL « 0x010d0004002207600d010025030099 (15 bytes) 17:25:09.875 CNTRLR [Node 034] [~] [Binary Switch] currentValue: false => false [Endpoint 1] 17:25:09.876 SERIAL » [ACK] (0x06) 17:25:09.879 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: false 17:25:09.885 SERIAL » 0x010a00131f037005052565ca (12 bytes) 17:25:09.886 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 101 └─[ConfigurationCCGet] parameter #: 5 17:25:09.887 CNTRLR « [Node 034] received Binary Switch state: [Endpoint 1] current value: false 17:25:09.887 CNTRLR [Node 034] [~] [Binary Switch] interviewComplete: true [Endpoint 1] [internal] => true 17:25:09.929 SERIAL « [ACK] (0x06) 17:25:09.935 SERIAL « 0x0104011301e8 (6 bytes) 17:25:09.936 SERIAL » [ACK] (0x06) 17:25:09.937 DRIVER « [RES] [SendData] was sent: true 17:25:09.941 CNTRLR [Node 034] MeterCC: doing a partial interview... [Endpoint 1] 17:25:09.941 CNTRLR » [Node 034] querying default meter value... [Endpoint 1] 17:25:09.946 SERIAL « 0x01070013650000028c (9 bytes) 17:25:09.947 SERIAL » [ACK] (0x06) 17:25:09.947 DRIVER « [REQ] [SendData] callback id: 101 transmit status: OK 17:25:09.952 SERIAL « 0x010c0004001f067006050200009f (14 bytes) 17:25:09.960 CNTRLR [Node 031] [~] [Configuration] 5: 0 => 0 17:25:09.961 SERIAL » [ACK] (0x06) 17:25:09.963 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 2 value: 0 17:25:09.967 SERIAL » 0x010a001323036009022566ee (12 bytes) 17:25:09.967 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 102 └─[MultiChannelCCCapabilityGet] endpoint: 2 17:25:09.968 CNTRLR « [Node 031] parameter #5 has value: 0 17:25:09.968 CNTRLR » [Node 031] querying parameter #6 value... 17:25:09.972 SERIAL « [ACK] (0x06) 17:25:09.977 SERIAL « 0x0104011301e8 (6 bytes) 17:25:09.977 SERIAL » [ACK] (0x06) 17:25:09.978 DRIVER « [RES] [SendData] was sent: true 17:25:11.331 SERIAL « 0x010700136600008805 (9 bytes) 17:25:11.331 SERIAL » [ACK] (0x06) 17:25:11.332 DRIVER « [REQ] [SendData] callback id: 102 transmit status: OK 17:25:11.416 SERIAL « 0x01160004002310600a0221015e8e31989f596c7180852213 (24 bytes) 17:25:11.418 CNTRLR [Node 035] [~] [Multi Channel] commandClasses: 94,142, [Endpoint 2] [internal] 49,152,159,89,108,113,128,133,34 => 94,142,49,152,159,89,108,113,128,133,34 17:25:11.418 SERIAL » [ACK] (0x06) 17:25:11.420 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 2 generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 17:25:11.427 SERIAL » 0x010a00132103850202256703 (12 bytes) 17:25:11.428 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 103 └─[AssociationCCGet] group id: 2 17:25:11.428 CNTRLR « [Node 035] received response for endpoint capabilities (#2): generic device class: Multilevel Sensor specific device class: Routing Multilevel Sensor is dynamic end point: false supported CCs: · Z-Wave Plus Info · Multi Channel Association · Multilevel Sensor · Security · Security 2 · Association Group Information · Supervision · Notification · Battery · Association · Application Status 17:25:11.429 CNTRLR [Node 035] [~] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] => true 17:25:11.482 SERIAL « [ACK] (0x06) 17:25:11.487 SERIAL « 0x0104011301e8 (6 bytes) 17:25:11.488 SERIAL » [ACK] (0x06) 17:25:11.489 DRIVER « [RES] [SendData] was sent: true 17:25:11.494 CNTRLR [Node 035] BatteryCC: doing a partial interview... 17:25:11.494 CNTRLR » [Node 035] querying battery status... 17:25:11.506 SERIAL « 0x01070013670000078b (9 bytes) 17:25:11.506 SERIAL » [ACK] (0x06) 17:25:11.507 DRIVER « [REQ] [SendData] callback id: 103 transmit status: OK 17:25:11.516 SERIAL « 0x010b0004002105850302050055 (13 bytes) 17:25:11.516 SERIAL » [ACK] (0x06) 17:25:11.518 CNTRLR [Node 033] [~] [Association] maxNodes[2]: 5 => 5 [internal] 17:25:11.518 CNTRLR [Node 033] [~] [Association] nodeIds[2]: => [internal] 17:25:11.519 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 2 max # of nodes: 5 node IDs: reports to follow: 0 17:25:11.532 SERIAL » 0x010d00132206600d000132012568d7 (15 bytes) 17:25:11.533 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 104 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[MeterCCGet] 17:25:11.534 CNTRLR « [Node 033] received information for association group #2: maximum # of nodes: 5 currently assigned nodes: 17:25:11.534 CNTRLR » [Node 033] querying association group #3... 17:25:11.538 SERIAL « [ACK] (0x06) 17:25:11.541 SERIAL « 0x0104011301e8 (6 bytes) 17:25:11.542 SERIAL » [ACK] (0x06) 17:25:11.542 DRIVER « [RES] [SendData] was sent: true 17:25:11.563 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 17:25:11.564 SERIAL » [ACK] (0x06) 17:25:11.565 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  17:25:11.567 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 17:25:11.610 SERIAL « 0x01070013680000088b (9 bytes) 17:25:11.610 SERIAL » [ACK] (0x06) 17:25:11.611 DRIVER « [REQ] [SendData] callback id: 104 transmit status: OK 17:25:11.627 SERIAL « 0x0112000400220c600d01003202014400000272ae (20 bytes) 17:25:11.628 CNTRLR [Node 034] [~] [Meter] value[65536]: 6.25 => 6.26 [Endpoint 1] 17:25:11.629 CNTRLR [Node 034] [~] [Meter] deltaTime[65536]: 0 => 0 [Endpoint 1] 17:25:11.629 SERIAL » [ACK] (0x06) 17:25:11.630 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[MeterCCReport] type: Electric scale: kWh rate type: Unspecified value: 6.26 time delta: 0 seconds 17:25:11.634 SERIAL » 0x010a00131f037005062569c5 (12 bytes) 17:25:11.634 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 105 └─[ConfigurationCCGet] parameter #: 6 17:25:11.635 CNTRLR [Node 034] [~] [Meter] interviewComplete: true => true [Endpoint 1] [internal] 17:25:11.636 CNTRLR [Node 034] ZWavePlusCC: doing a partial interview... [Endpoint 2] 17:25:11.636 CNTRLR [Node 034] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 17:25:11.637 CNTRLR [Node 034] BinarySwitchCC: doing a partial interview... [Endpoint 2] 17:25:11.637 CNTRLR » [Node 034] querying Binary Switch state... [Endpoint 2] 17:25:11.640 SERIAL « [ACK] (0x06) 17:25:11.642 SERIAL « 0x0104011301e8 (6 bytes) 17:25:11.643 SERIAL » [ACK] (0x06) 17:25:11.644 DRIVER « [RES] [SendData] was sent: true 17:25:11.673 SERIAL « 0x010700136900000381 (9 bytes) 17:25:11.674 SERIAL » [ACK] (0x06) 17:25:11.674 DRIVER « [REQ] [SendData] callback id: 105 transmit status: OK 17:25:11.677 SERIAL « 0x010b0004001f0570060601009b (13 bytes) 17:25:11.682 CNTRLR [Node 031] [~] [Configuration] 6: 0 => 0 17:25:11.683 SERIAL » [ACK] (0x06) 17:25:11.684 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 1 value: 0 17:25:11.687 SERIAL » 0x0109001323028002256a09 (11 bytes) 17:25:11.687 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 106 └─[BatteryCCGet] 17:25:11.687 CNTRLR « [Node 031] parameter #6 has value: 0 17:25:11.688 CNTRLR » [Node 031] querying parameter #7 value... 17:25:11.691 SERIAL « [ACK] (0x06) 17:25:11.696 SERIAL « 0x0104011301e8 (6 bytes) 17:25:11.696 SERIAL » [ACK] (0x06) 17:25:11.697 DRIVER « [RES] [SendData] was sent: true 17:25:12.627 DRIVER The awake timeout for node 17 has elapsed. Assuming it is asleep. 17:25:12.628 CNTRLR [Node 017] The node is now asleep. 17:25:13.066 SERIAL « 0x010700136a00008908 (9 bytes) 17:25:13.067 SERIAL » [ACK] (0x06) 17:25:13.067 DRIVER « [REQ] [SendData] callback id: 106 transmit status: OK 17:25:13.180 SERIAL « 0x0109000400230380036435 (11 bytes) 17:25:13.181 CNTRLR [Node 035] [~] [Battery] level: 100 => 100 [Endpoint 0] 17:25:13.182 CNTRLR [Node 035] [~] [Battery] isLow: false => false [Endpoint 0] 17:25:13.182 SERIAL » [ACK] (0x06) 17:25:13.184 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 17:25:13.187 SERIAL » 0x010a00132103850203256b0e (12 bytes) 17:25:13.188 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 107 └─[AssociationCCGet] group id: 3 17:25:13.188 CNTRLR « [Node 035] received response for battery information: level: 100 17:25:13.188 CNTRLR [Node 035] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:25:13.219 SERIAL « [ACK] (0x06) 17:25:13.222 SERIAL « 0x0104011301e8 (6 bytes) 17:25:13.223 SERIAL » [ACK] (0x06) 17:25:13.224 DRIVER « [RES] [SendData] was sent: true 17:25:13.229 CNTRLR [Node 035] ZWavePlusCC: doing a partial interview... [Endpoint 1] 17:25:13.229 CNTRLR [Node 035] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue => true 17:25:13.230 CNTRLR [Node 035] ThermostatModeCC: doing a partial interview... [Endpoint 1] 17:25:13.230 CNTRLR » [Node 035] querying current thermostat mode... [Endpoint 1] 17:25:13.276 SERIAL « 0x010700136b00000888 (9 bytes) 17:25:13.276 SERIAL » [ACK] (0x06) 17:25:13.278 DRIVER « [REQ] [SendData] callback id: 107 transmit status: OK 17:25:13.286 SERIAL « 0x010b0004002105850303050054 (13 bytes) 17:25:13.287 SERIAL » [ACK] (0x06) 17:25:13.289 CNTRLR [Node 033] [~] [Association] maxNodes[3]: 5 => 5 [internal] 17:25:13.289 CNTRLR [Node 033] [~] [Association] nodeIds[3]: => [internal] 17:25:13.290 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 5 node IDs: reports to follow: 0 17:25:13.297 SERIAL » 0x010d00132206600d00022502256cc4 (15 bytes) 17:25:13.298 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 108 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[BinarySwitchCCGet] 17:25:13.299 CNTRLR « [Node 033] received information for association group #3: maximum # of nodes: 5 currently assigned nodes: 17:25:13.299 CNTRLR » [Node 033] querying association group #4... 17:25:13.305 SERIAL « [ACK] (0x06) 17:25:13.308 SERIAL « 0x0104011301e8 (6 bytes) 17:25:13.308 SERIAL » [ACK] (0x06) 17:25:13.310 DRIVER « [RES] [SendData] was sent: true 17:25:13.330 SERIAL « 0x010700136c00000285 (9 bytes) 17:25:13.331 SERIAL » [ACK] (0x06) 17:25:13.332 DRIVER « [REQ] [SendData] callback id: 108 transmit status: OK 17:25:13.343 SERIAL « 0x010d0004002207600d02002503009a (15 bytes) 17:25:13.345 CNTRLR [Node 034] [~] [Binary Switch] currentValue: false => false [Endpoint 2] 17:25:13.346 SERIAL » [ACK] (0x06) 17:25:13.350 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BinarySwitchCCReport] current value: false 17:25:13.357 SERIAL » 0x010a00131f03700507256dc0 (12 bytes) 17:25:13.358 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 109 └─[ConfigurationCCGet] parameter #: 7 17:25:13.359 CNTRLR « [Node 034] received Binary Switch state: [Endpoint 2] current value: false 17:25:13.359 CNTRLR [Node 034] [~] [Binary Switch] interviewComplete: true [Endpoint 2] [internal] => true 17:25:13.360 CNTRLR [Node 034] MeterCC: doing a partial interview... [Endpoint 2] 17:25:13.361 CNTRLR » [Node 034] querying default meter value... [Endpoint 2] 17:25:13.368 SERIAL « [ACK] (0x06) 17:25:13.369 SERIAL « 0x0104011301e8 (6 bytes) 17:25:13.370 SERIAL » [ACK] (0x06) 17:25:13.371 DRIVER « [RES] [SendData] was sent: true 17:25:13.414 SERIAL « 0x010700136d00000284 (9 bytes) 17:25:13.415 SERIAL » [ACK] (0x06) 17:25:13.416 DRIVER « [REQ] [SendData] callback id: 109 transmit status: OK 17:25:13.418 SERIAL « 0x010b0004001f0570060701009a (13 bytes) 17:25:13.423 CNTRLR [Node 031] [~] [Configuration] 7: 0 => 0 17:25:13.424 SERIAL » [ACK] (0x06) 17:25:13.425 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 7 value size: 1 value: 0 17:25:13.428 SERIAL » 0x010d00132306600d00014002256ea1 (15 bytes) 17:25:13.428 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 110 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatModeCCGet] 17:25:13.429 CNTRLR « [Node 031] parameter #7 has value: 0 17:25:13.429 CNTRLR » [Node 031] querying parameter #13 value... 17:25:13.432 SERIAL « [ACK] (0x06) 17:25:13.439 SERIAL « 0x0104011301e8 (6 bytes) 17:25:13.440 SERIAL » [ACK] (0x06) 17:25:13.441 DRIVER « [RES] [SendData] was sent: true 17:25:13.494 SERIAL « 0x010700136e00000683 (9 bytes) 17:25:13.495 SERIAL » [ACK] (0x06) 17:25:13.495 DRIVER « [REQ] [SendData] callback id: 110 transmit status: OK 17:25:13.582 SERIAL « 0x010d0004002307600d0100400301fc (15 bytes) 17:25:13.583 CNTRLR [Node 035] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 1] 17:25:13.583 SERIAL » [ACK] (0x06) 17:25:13.585 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatModeCCReport] mode: Heat 17:25:13.588 SERIAL » 0x010a00132103850204256f0d (12 bytes) 17:25:13.589 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 111 └─[AssociationCCGet] group id: 4 17:25:13.589 CNTRLR « [Node 035] received current thermostat mode: Heat [Endpoint 1] 17:25:13.590 CNTRLR [Node 035] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 1] [internal] ue => true 17:25:13.618 SERIAL « [ACK] (0x06) 17:25:13.622 SERIAL « 0x0104011301e8 (6 bytes) 17:25:13.623 SERIAL » [ACK] (0x06) 17:25:13.624 DRIVER « [RES] [SendData] was sent: true 17:25:13.626 CNTRLR [Node 035] ThermostatSetpointCC: doing a partial interview... [Endpoint 1] 17:25:13.627 CNTRLR » [Node 035] querying current value of setpoint Heating... [Endpoint 1] 17:25:13.676 SERIAL « 0x010700136f0000088c (9 bytes) 17:25:13.676 SERIAL » [ACK] (0x06) 17:25:13.677 DRIVER « [REQ] [SendData] callback id: 111 transmit status: OK 17:25:13.686 SERIAL « 0x010b0004002105850304050053 (13 bytes) 17:25:13.687 SERIAL » [ACK] (0x06) 17:25:13.688 CNTRLR [Node 033] [~] [Association] maxNodes[4]: 5 => 5 [internal] 17:25:13.688 CNTRLR [Node 033] [~] [Association] nodeIds[4]: => [internal] 17:25:13.688 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 4 max # of nodes: 5 node IDs: reports to follow: 0 17:25:13.692 SERIAL » 0x010d00132206600d000232012570cc (15 bytes) 17:25:13.692 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 112 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MeterCCGet] 17:25:13.693 CNTRLR « [Node 033] received information for association group #4: maximum # of nodes: 5 currently assigned nodes: 17:25:13.693 CNTRLR » [Node 033] querying association group #5... 17:25:13.696 SERIAL « [ACK] (0x06) 17:25:13.700 SERIAL « 0x0104011301e8 (6 bytes) 17:25:13.701 SERIAL » [ACK] (0x06) 17:25:13.701 DRIVER « [RES] [SendData] was sent: true 17:25:13.722 SERIAL « 0x010700137000000398 (9 bytes) 17:25:13.722 SERIAL » [ACK] (0x06) 17:25:13.723 DRIVER « [REQ] [SendData] callback id: 112 transmit status: OK 17:25:13.738 SERIAL « 0x0112000400220c600d020032020144000000934e (20 bytes) 17:25:13.739 CNTRLR [Node 034] [~] [Meter] value[65536]: 1.47 => 1.47 [Endpoint 2] 17:25:13.740 CNTRLR [Node 034] [~] [Meter] deltaTime[65536]: 0 => 0 [Endpoint 2] 17:25:13.741 SERIAL » [ACK] (0x06) 17:25:13.742 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: kWh rate type: Unspecified value: 1.47 time delta: 0 seconds 17:25:13.746 SERIAL » 0x010a00131f0370050d2571d6 (12 bytes) 17:25:13.746 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 113 └─[ConfigurationCCGet] parameter #: 13 17:25:13.747 CNTRLR [Node 034] [~] [Meter] interviewComplete: true => true [Endpoint 2] [internal] 17:25:13.747 CNTRLR [Node 034] BinarySwitchCC: doing a partial interview... 17:25:13.747 CNTRLR » [Node 034] querying Binary Switch state... 17:25:13.751 SERIAL « [ACK] (0x06) 17:25:13.754 SERIAL « 0x0104011301e8 (6 bytes) 17:25:13.755 SERIAL » [ACK] (0x06) 17:25:13.755 DRIVER « [RES] [SendData] was sent: true 17:25:13.771 SERIAL « 0x010700137100000298 (9 bytes) 17:25:13.772 SERIAL » [ACK] (0x06) 17:25:13.773 DRIVER « [REQ] [SendData] callback id: 113 transmit status: OK 17:25:13.782 SERIAL « 0x010b0004001f0570060d010090 (13 bytes) 17:25:13.788 CNTRLR [Node 031] [~] [Configuration] 13: 0 => 0 17:25:13.789 SERIAL » [ACK] (0x06) 17:25:13.790 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 0 17:25:13.793 SERIAL » 0x010e00132307600d00014302012572bd (16 bytes) 17:25:13.794 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 114 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 17:25:13.794 CNTRLR « [Node 031] parameter #13 has value: 0 17:25:13.794 CNTRLR » [Node 031] querying parameter #14 value... 17:25:13.797 SERIAL « [ACK] (0x06) 17:25:13.802 SERIAL « 0x0104011301e8 (6 bytes) 17:25:13.803 SERIAL » [ACK] (0x06) 17:25:13.804 DRIVER « [RES] [SendData] was sent: true 17:25:13.860 SERIAL « 0x01070013720000079e (9 bytes) 17:25:13.860 SERIAL » [ACK] (0x06) 17:25:13.861 DRIVER « [REQ] [SendData] callback id: 114 transmit status: OK 17:25:13.880 SERIAL « 0x010c000400030631050422045db9 (14 bytes) 17:25:13.881 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:25:13.882 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 238.5 => 111.7 [Endpoint 0] 17:25:13.883 SERIAL » [ACK] (0x06) 17:25:13.884 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 111.7 17:25:13.943 SERIAL « 0x0110000400230a600d0100430301220064a9 (18 bytes) 17:25:13.945 CNTRLR [Node 035] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 1] 17:25:13.946 CNTRLR [Node 035] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 17:25:13.946 SERIAL » [ACK] (0x06) 17:25:13.947 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 17:25:13.951 SERIAL » 0x010a00132103850205257310 (12 bytes) 17:25:13.951 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 115 └─[AssociationCCGet] group id: 5 17:25:13.952 CNTRLR « [Node 035] received current value of setpoint Heating: 10 °C [Endpoint 1] 17:25:13.953 CNTRLR [Node 035] [~] [Thermostat Setpoint] interviewComplete [Endpoint 1] [internal] : true => true 17:25:13.953 CNTRLR [Node 035] NotificationCC: doing a partial interview... [Endpoint 1] 17:25:13.954 CNTRLR » [Node 035] querying notification status for Power Management... [Endpoint 1] 17:25:13.958 SERIAL « [ACK] (0x06) 17:25:13.965 SERIAL « 0x0104011301e8 (6 bytes) 17:25:13.966 SERIAL » [ACK] (0x06) 17:25:13.967 DRIVER « [RES] [SendData] was sent: true 17:25:14.036 SERIAL « 0x010700137300000890 (9 bytes) 17:25:14.036 SERIAL » [ACK] (0x06) 17:25:14.037 DRIVER « [REQ] [SendData] callback id: 115 transmit status: OK 17:25:14.048 SERIAL « 0x010c000400210685030501000153 (14 bytes) 17:25:14.049 SERIAL » [ACK] (0x06) 17:25:14.052 CNTRLR [Node 033] [~] [Association] maxNodes[5]: 1 => 1 [internal] 17:25:14.053 CNTRLR [Node 033] [~] [Association] nodeIds[5]: 1 => 1 [internal] 17:25:14.053 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 5 max # of nodes: 1 node IDs: 1 reports to follow: 0 17:25:14.059 SERIAL » 0x01090013220225022574b3 (11 bytes) 17:25:14.060 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 116 └─[BinarySwitchCCGet] 17:25:14.061 CNTRLR « [Node 033] received information for association group #5: maximum # of nodes: 1 currently assigned nodes: 1 17:25:14.063 CNTRLR [Node 033] [~] [Association] hasLifeline: true => true [internal] 17:25:14.064 CNTRLR [Node 033] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:25:14.065 CNTRLR [Node 033] MultilevelSwitchCC: doing a partial interview... [Endpoint 1] 17:25:14.065 CNTRLR » [Node 033] requesting current switch state... [Endpoint 1] 17:25:14.071 SERIAL « [ACK] (0x06) 17:25:14.073 SERIAL « 0x0104011301e8 (6 bytes) 17:25:14.073 SERIAL » [ACK] (0x06) 17:25:14.074 DRIVER « [RES] [SendData] was sent: true 17:25:14.089 SERIAL « 0x01070013740000039c (9 bytes) 17:25:14.089 SERIAL » [ACK] (0x06) 17:25:14.090 DRIVER « [REQ] [SendData] callback id: 116 transmit status: OK 17:25:14.102 SERIAL « 0x01090004002203250300f5 (11 bytes) 17:25:14.103 CNTRLR [Node 034] [~] [Binary Switch] currentValue: false => false [Endpoint 0] 17:25:14.104 SERIAL » [ACK] (0x06) 17:25:14.105 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 17:25:14.108 SERIAL » 0x010a00131f0370050e2575d1 (12 bytes) 17:25:14.108 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 117 └─[ConfigurationCCGet] parameter #: 14 17:25:14.109 CNTRLR « [Node 034] received Binary Switch state: current value: false 17:25:14.109 CNTRLR [Node 034] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 17:25:14.109 CNTRLR [Node 034] MeterCC: doing a partial interview... 17:25:14.110 CNTRLR » [Node 034] querying meter value (type = Electric, scale = kWh)... 17:25:14.113 SERIAL « [ACK] (0x06) 17:25:14.118 SERIAL « 0x0104011301e8 (6 bytes) 17:25:14.118 SERIAL » [ACK] (0x06) 17:25:14.119 DRIVER « [RES] [SendData] was sent: true 17:25:14.133 SERIAL « 0x01070013750000029c (9 bytes) 17:25:14.134 SERIAL » [ACK] (0x06) 17:25:14.134 DRIVER « [REQ] [SendData] callback id: 117 transmit status: OK 17:25:14.144 SERIAL « 0x010b0004001f0570060e010192 (13 bytes) 17:25:14.149 CNTRLR [Node 031] [~] [Configuration] 14: 1 => 1 17:25:14.150 SERIAL » [ACK] (0x06) 17:25:14.151 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 1 17:25:14.154 SERIAL » 0x011000132309600d00017104000800257694 (18 bytes) 17:25:14.155 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 118 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: Power Management 17:25:14.155 CNTRLR « [Node 031] parameter #14 has value: 1 17:25:14.155 CNTRLR » [Node 031] querying parameter #15 value... 17:25:14.159 SERIAL « [ACK] (0x06) 17:25:14.168 SERIAL « 0x0104011301e8 (6 bytes) 17:25:14.168 SERIAL » [ACK] (0x06) 17:25:14.169 DRIVER « [RES] [SendData] was sent: true 17:25:14.223 SERIAL « 0x01070013760000079a (9 bytes) 17:25:14.224 SERIAL » [ACK] (0x06) 17:25:14.224 DRIVER « [REQ] [SendData] callback id: 118 transmit status: OK 17:25:14.315 SERIAL « 0x0113000400230d600d01007105000000ff08fe00d7 (21 bytes) 17:25:14.316 SERIAL » [ACK] (0x06) 17:25:14.317 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 17:25:14.320 SERIAL » 0x010d00132106600d000126022577dc (15 bytes) 17:25:14.320 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 119 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[MultilevelSwitchCCGet] 17:25:14.321 CNTRLR [Node 035] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 1] 54 17:25:14.322 CNTRLR » [Node 035] querying notification status for System... [Endpoint 1] 17:25:14.325 SERIAL « [ACK] (0x06) 17:25:14.328 SERIAL « 0x0104011301e8 (6 bytes) 17:25:14.329 SERIAL » [ACK] (0x06) 17:25:14.329 DRIVER « [RES] [SendData] was sent: true 17:25:14.406 SERIAL « 0x010700137700000894 (9 bytes) 17:25:14.406 SERIAL » [ACK] (0x06) 17:25:14.407 DRIVER « [REQ] [SendData] callback id: 119 transmit status: OK 17:25:14.435 SERIAL « 0x010d0004002107600d010126030098 (15 bytes) 17:25:14.436 CNTRLR [Node 033] [~] [Multilevel Switch] currentValue: 0 => 0 [Endpoint 1] 17:25:14.437 SERIAL » [ACK] (0x06) 17:25:14.439 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 1 └─[MultilevelSwitchCCReport] current value: 0 17:25:14.442 SERIAL » 0x010a001322033201002578a9 (12 bytes) 17:25:14.443 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 120 └─[MeterCCGet] duration: kWh 17:25:14.444 CNTRLR [Node 033] [~] [Multilevel Switch] interviewComplete: [Endpoint 1] [internal] true => true 17:25:14.444 CNTRLR [Node 033] MultilevelSwitchCC: doing a partial interview... [Endpoint 2] 17:25:14.445 CNTRLR » [Node 033] requesting current switch state... [Endpoint 2] 17:25:14.452 SERIAL « [ACK] (0x06) 17:25:14.452 SERIAL « 0x0104011301e8 (6 bytes) 17:25:14.453 SERIAL » [ACK] (0x06) 17:25:14.456 DRIVER « [RES] [SendData] was sent: true 17:25:14.472 SERIAL « 0x010700137800000390 (9 bytes) 17:25:14.472 SERIAL » [ACK] (0x06) 17:25:14.473 DRIVER « [REQ] [SendData] callback id: 120 transmit status: OK 17:25:14.487 SERIAL « 0x0110000400220a32022144000002720000e6 (18 bytes) 17:25:14.489 CNTRLR [Node 034] [~] [Meter] value[65537]: 6.25 => 6.26 [Endpoint 0] 17:25:14.489 CNTRLR [Node 034] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 17:25:14.489 SERIAL » [ACK] (0x06) 17:25:14.490 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 6.26 time delta: 0 seconds 17:25:14.493 SERIAL » 0x010a00131f0370050f2579dc (12 bytes) 17:25:14.494 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 121 └─[ConfigurationCCGet] parameter #: 15 17:25:14.494 CNTRLR » [Node 034] querying meter value (type = Electric, scale = W)... 17:25:14.497 SERIAL « [ACK] (0x06) 17:25:14.501 SERIAL « 0x0104011301e8 (6 bytes) 17:25:14.502 SERIAL » [ACK] (0x06) 17:25:14.502 DRIVER « [RES] [SendData] was sent: true 17:25:14.519 SERIAL « 0x010700137900000391 (9 bytes) 17:25:14.519 SERIAL » [ACK] (0x06) 17:25:14.520 DRIVER « [REQ] [SendData] callback id: 121 transmit status: OK 17:25:14.530 SERIAL « 0x010b0004001f0570060f010092 (13 bytes) 17:25:14.535 CNTRLR [Node 031] [~] [Configuration] 15: 0 => 0 17:25:14.536 SERIAL » [ACK] (0x06) 17:25:14.537 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 15 value size: 1 value: 0 17:25:14.540 SERIAL » 0x011000132309600d00017104000900257a99 (18 bytes) 17:25:14.541 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 122 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[NotificationCCGet] notification type: System 17:25:14.541 CNTRLR « [Node 031] parameter #15 has value: 0 17:25:14.541 CNTRLR » [Node 031] querying parameter #16 value... 17:25:14.549 SERIAL « [ACK] (0x06) 17:25:14.551 SERIAL « 0x0104011301e8 (6 bytes) 17:25:14.551 SERIAL » [ACK] (0x06) 17:25:14.552 DRIVER « [RES] [SendData] was sent: true 17:25:14.610 SERIAL « 0x010700137a00000796 (9 bytes) 17:25:14.610 SERIAL » [ACK] (0x06) 17:25:14.610 DRIVER « [REQ] [SendData] callback id: 122 transmit status: OK 17:25:14.695 SERIAL « 0x0113000400230d600d01007105000000ff09fe00d6 (21 bytes) 17:25:14.696 SERIAL » [ACK] (0x06) 17:25:14.696 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: System notification status: 255 notification event: Unknown (0xfe) 17:25:14.699 SERIAL » 0x010d00132106600d00022602257bd3 (15 bytes) 17:25:14.700 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 123 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MultilevelSwitchCCGet] 17:25:14.700 CNTRLR [Node 035] [~] [Notification] System[unknown]: 254 => 254 [Endpoint 1] 17:25:14.701 CNTRLR [Node 035] [~] [Notification] interviewComplete: true [Endpoint 1] [internal] => true 17:25:14.702 CNTRLR [Node 035] ProtectionCC: doing a partial interview... 17:25:14.702 CNTRLR » [Node 035] querying protection status... 17:25:14.706 SERIAL « [ACK] (0x06) 17:25:14.708 SERIAL « 0x0104011301e8 (6 bytes) 17:25:14.708 SERIAL » [ACK] (0x06) 17:25:14.709 DRIVER « [RES] [SendData] was sent: true 17:25:14.786 SERIAL « 0x010700137b00000898 (9 bytes) 17:25:14.786 SERIAL » [ACK] (0x06) 17:25:14.787 DRIVER « [REQ] [SendData] callback id: 123 transmit status: OK 17:25:14.816 SERIAL « 0x010d0004002107600d020226030098 (15 bytes) 17:25:14.818 CNTRLR [Node 033] [~] [Multilevel Switch] currentValue: 0 => 0 [Endpoint 2] 17:25:14.819 SERIAL » [ACK] (0x06) 17:25:14.820 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 2 └─[MultilevelSwitchCCReport] current value: 0 17:25:14.826 SERIAL » 0x010a00132203320110257cbd (12 bytes) 17:25:14.827 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 124 └─[MeterCCGet] duration: W 17:25:14.828 CNTRLR [Node 033] [~] [Multilevel Switch] interviewComplete: [Endpoint 2] [internal] true => true 17:25:14.829 CNTRLR [Node 033] MultilevelSwitchCC: doing a partial interview... [Endpoint 3] 17:25:14.829 CNTRLR » [Node 033] requesting current switch state... [Endpoint 3] 17:25:14.837 SERIAL « [ACK] (0x06) 17:25:14.838 SERIAL « 0x0104011301e8 (6 bytes) 17:25:14.839 SERIAL » [ACK] (0x06) 17:25:14.840 DRIVER « [RES] [SendData] was sent: true 17:25:14.856 SERIAL « 0x010700137c00000295 (9 bytes) 17:25:14.856 SERIAL » [ACK] (0x06) 17:25:14.858 DRIVER « [REQ] [SendData] callback id: 124 transmit status: OK 17:25:14.871 SERIAL « 0x010e00040022083202213200000000fc (16 bytes) 17:25:14.872 CNTRLR [Node 034] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 17:25:14.873 CNTRLR [Node 034] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 17:25:14.873 SERIAL » [ACK] (0x06) 17:25:14.875 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 17:25:14.881 SERIAL » 0x010a00131f03700510257dc7 (12 bytes) 17:25:14.881 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 125 └─[ConfigurationCCGet] parameter #: 16 17:25:14.883 CNTRLR [Node 034] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 17:25:14.884 CNTRLR [Node 034] ConfigurationCC: Loading configuration parameters from device confi g 17:25:14.893 CNTRLR [Node 034] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:25:14.894 CNTRLR [Node 034] [Configuration] 9: metadata updated 17:25:14.895 CNTRLR [Node 034] [Configuration] 10: metadata updated 17:25:14.897 CNTRLR [Node 034] [Configuration] 11: metadata updated 17:25:14.898 CNTRLR [Node 034] [Configuration] 12: metadata updated 17:25:14.899 CNTRLR [Node 034] [Configuration] 13: metadata updated 17:25:14.900 CNTRLR [Node 034] [Configuration] 15: metadata updated 17:25:14.901 CNTRLR [Node 034] [Configuration] 16: metadata updated 17:25:14.902 CNTRLR [Node 034] [Configuration] 17: metadata updated 17:25:14.903 CNTRLR [Node 034] [Configuration] 18: metadata updated 17:25:14.904 CNTRLR [Node 034] [Configuration] 20: metadata updated 17:25:14.905 CNTRLR [Node 034] [Configuration] 21: metadata updated 17:25:14.907 CNTRLR [Node 034] [Configuration] 27: metadata updated 17:25:14.908 CNTRLR [Node 034] [Configuration] 28: metadata updated 17:25:14.909 CNTRLR [Node 034] [Configuration] 29: metadata updated 17:25:14.910 CNTRLR [Node 034] [Configuration] 30: metadata updated 17:25:14.911 CNTRLR [Node 034] [Configuration] 31: metadata updated 17:25:14.912 CNTRLR [Node 034] [Configuration] 32: metadata updated 17:25:14.913 CNTRLR [Node 034] [Configuration] 33: metadata updated 17:25:14.914 CNTRLR [Node 034] [Configuration] 35: metadata updated 17:25:14.915 CNTRLR [Node 034] [Configuration] 36: metadata updated 17:25:14.916 CNTRLR [Node 034] [Configuration] 37: metadata updated 17:25:14.917 CNTRLR [Node 034] [Configuration] 38: metadata updated 17:25:14.918 CNTRLR [Node 034] [Configuration] 40: metadata updated 17:25:14.919 CNTRLR [Node 034] [Configuration] 41: metadata updated 17:25:14.920 CNTRLR [Node 034] [Configuration] 42: metadata updated 17:25:14.921 CNTRLR [Node 034] [Configuration] 43: metadata updated 17:25:14.922 CNTRLR [Node 034] [Configuration] 44: metadata updated 17:25:14.923 CNTRLR [Node 034] [Configuration] 50: metadata updated 17:25:14.924 CNTRLR [Node 034] [Configuration] 51: metadata updated 17:25:14.925 CNTRLR [Node 034] [Configuration] 53: metadata updated 17:25:14.926 CNTRLR [Node 034] [Configuration] 54: metadata updated 17:25:14.927 CNTRLR [Node 034] [Configuration] 55: metadata updated 17:25:14.928 CNTRLR [Node 034] [Configuration] 57: metadata updated 17:25:14.929 CNTRLR [Node 034] [Configuration] 58: metadata updated 17:25:14.930 CNTRLR [Node 034] [Configuration] 59: metadata updated 17:25:14.931 CNTRLR [Node 034] [Configuration] 60: metadata updated 17:25:14.932 CNTRLR [Node 034] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:25:14.933 CNTRLR » [Node 034] querying parameter #9 value... 17:25:14.947 SERIAL « [ACK] (0x06) 17:25:14.948 SERIAL « 0x0104011301e8 (6 bytes) 17:25:14.948 SERIAL » [ACK] (0x06) 17:25:14.950 DRIVER « [RES] [SendData] was sent: true 17:25:14.986 SERIAL « 0x010700137d00000294 (9 bytes) 17:25:14.988 SERIAL » [ACK] (0x06) 17:25:14.994 DRIVER « [REQ] [SendData] callback id: 125 transmit status: OK 17:25:15.000 SERIAL « 0x010b0004001f0570061001018c (13 bytes) 17:25:15.006 CNTRLR [Node 031] [~] [Configuration] 16: 1 => 1 17:25:15.007 SERIAL » [ACK] (0x06) 17:25:15.010 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 1 17:25:15.015 SERIAL » 0x010d00132306600d00017502257e84 (15 bytes) 17:25:15.016 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 126 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ProtectionCCGet] 17:25:15.017 CNTRLR « [Node 031] parameter #16 has value: 1 17:25:15.017 CNTRLR » [Node 031] querying parameter #30 value... 17:25:15.023 SERIAL « [ACK] (0x06) 17:25:15.040 SERIAL « 0x0104011301e8 (6 bytes) 17:25:15.040 SERIAL » [ACK] (0x06) 17:25:15.056 DRIVER « [RES] [SendData] was sent: true 17:25:15.082 SERIAL « 0x010700137e00000693 (9 bytes) 17:25:15.083 SERIAL » [ACK] (0x06) 17:25:15.084 DRIVER « [REQ] [SendData] callback id: 126 transmit status: OK 17:25:15.162 SERIAL « 0x010d0004002307600d0100750300c8 (15 bytes) 17:25:15.163 CNTRLR [Node 035] [~] [Protection] local: 0 => 0 [Endpoint 1] 17:25:15.163 SERIAL » [ACK] (0x06) 17:25:15.165 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ProtectionCCReport] local: Unprotected 17:25:15.168 SERIAL » 0x010d00132106600d00032602257fd6 (15 bytes) 17:25:15.168 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 127 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 3 └─[MultilevelSwitchCCGet] 17:25:15.169 CNTRLR « [Node 035] received protection status: local: Unprotected 17:25:15.169 CNTRLR [Node 035] [~] [Protection] interviewComplete: true => [Endpoint 1] [internal] true 17:25:15.170 CNTRLR [Node 035] BatteryCC: doing a partial interview... [Endpoint 1] 17:25:15.170 CNTRLR » [Node 035] querying battery status... [Endpoint 1] 17:25:15.174 SERIAL « [ACK] (0x06) 17:25:15.177 SERIAL « 0x0104011301e8 (6 bytes) 17:25:15.177 SERIAL » [ACK] (0x06) 17:25:15.178 DRIVER « [RES] [SendData] was sent: true 17:25:15.257 SERIAL « 0x010700137f0000089c (9 bytes) 17:25:15.257 SERIAL » [ACK] (0x06) 17:25:15.258 DRIVER « [REQ] [SendData] callback id: 127 transmit status: OK 17:25:15.285 SERIAL « 0x010d0004002107600d030326030098 (15 bytes) 17:25:15.286 CNTRLR [Node 033] [~] [Multilevel Switch] currentValue: 0 => 0 [Endpoint 3] 17:25:15.287 SERIAL » [ACK] (0x06) 17:25:15.288 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 3 │ destination: 3 └─[MultilevelSwitchCCReport] current value: 0 17:25:15.291 SERIAL » 0x010a0013220370050925801e (12 bytes) 17:25:15.292 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 128 └─[ConfigurationCCGet] parameter #: 9 17:25:15.292 CNTRLR [Node 033] [~] [Multilevel Switch] interviewComplete: [Endpoint 3] [internal] true => true 17:25:15.293 CNTRLR [Node 033] MultilevelSwitchCC: doing a partial interview... [Endpoint 4] 17:25:15.293 CNTRLR » [Node 033] requesting current switch state... [Endpoint 4] 17:25:15.302 SERIAL « [ACK] (0x06) 17:25:15.303 SERIAL « 0x0104011301e8 (6 bytes) 17:25:15.303 SERIAL » [ACK] (0x06) 17:25:15.304 DRIVER « [RES] [SendData] was sent: true 17:25:15.320 SERIAL « 0x010700138000000368 (9 bytes) 17:25:15.321 SERIAL » [ACK] (0x06) 17:25:15.321 DRIVER « [REQ] [SendData] callback id: 128 transmit status: OK 17:25:15.334 SERIAL « 0x010b00040022057006090101a8 (13 bytes) 17:25:15.340 CNTRLR [Node 034] [~] [Configuration] 9: 1 => 1 17:25:15.340 SERIAL » [ACK] (0x06) 17:25:15.341 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 1 value: 1 17:25:15.354 SERIAL » 0x010a00131f0370051e258135 (12 bytes) 17:25:15.354 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 129 └─[ConfigurationCCGet] parameter #: 30 17:25:15.354 CNTRLR « [Node 034] parameter #9 has value: 1 17:25:15.355 CNTRLR » [Node 034] querying parameter #10 value... 17:25:15.359 SERIAL « [ACK] (0x06) 17:25:15.365 SERIAL « 0x0104011301e8 (6 bytes) 17:25:15.366 SERIAL » [ACK] (0x06) 17:25:15.366 DRIVER « [RES] [SendData] was sent: true 17:25:15.385 SERIAL « 0x010700138100000268 (9 bytes) 17:25:15.386 SERIAL » [ACK] (0x06) 17:25:15.387 DRIVER « [REQ] [SendData] callback id: 129 transmit status: OK 17:25:15.394 SERIAL « 0x010b0004001f0570061e010380 (13 bytes) 17:25:15.399 CNTRLR [Node 031] [~] [Configuration] 30: 3 => 3 17:25:15.401 SERIAL » [ACK] (0x06) 17:25:15.402 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 3 17:25:15.406 SERIAL » 0x010d00132306600d0001800225828d (15 bytes) 17:25:15.408 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 130 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BatteryCCGet] 17:25:15.408 CNTRLR « [Node 031] parameter #30 has value: 3 17:25:15.408 CNTRLR » [Node 031] querying parameter #31 value... 17:25:15.412 SERIAL « [ACK] (0x06) 17:25:15.416 SERIAL « 0x0104011301e8 (6 bytes) 17:25:15.417 SERIAL » [ACK] (0x06) 17:25:15.419 DRIVER « [RES] [SendData] was sent: true 17:25:15.475 SERIAL « 0x01070013820000066f (9 bytes) 17:25:15.475 SERIAL » [ACK] (0x06) 17:25:15.476 DRIVER « [REQ] [SendData] callback id: 130 transmit status: OK 17:25:15.562 SERIAL « 0x010d0004002307600d010080036459 (15 bytes) 17:25:15.563 CNTRLR [Node 035] [~] [Battery] level: 100 => 100 [Endpoint 1] 17:25:15.563 CNTRLR [Node 035] [~] [Battery] isLow: false => false [Endpoint 1] 17:25:15.564 SERIAL » [ACK] (0x06) 17:25:15.565 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BatteryCCReport] level: 100 is low: false 17:25:15.568 SERIAL » 0x010d00132106600d0004260225832d (15 bytes) 17:25:15.568 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 131 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 4 └─[MultilevelSwitchCCGet] 17:25:15.569 CNTRLR « [Node 035] received response for battery information: [Endpoint 1] level: 100 17:25:15.569 CNTRLR [Node 035] [~] [Battery] interviewComplete: true => tr [Endpoint 1] [internal] ue 17:25:15.569 CNTRLR [Node 035] ClockCC: doing a partial interview... 17:25:15.570 CNTRLR » [Node 035] requesting current clock setting... 17:25:15.573 SERIAL « [ACK] (0x06) 17:25:15.577 SERIAL « 0x0104011301e8 (6 bytes) 17:25:15.577 SERIAL » [ACK] (0x06) 17:25:15.577 DRIVER « [RES] [SendData] was sent: true 17:25:15.656 SERIAL « 0x010700138300000860 (9 bytes) 17:25:15.656 SERIAL » [ACK] (0x06) 17:25:15.657 DRIVER « [REQ] [SendData] callback id: 131 transmit status: OK 17:25:15.686 SERIAL « 0x010d0004002107600d040426030098 (15 bytes) 17:25:15.687 CNTRLR [Node 033] [~] [Multilevel Switch] currentValue: 0 => 0 [Endpoint 4] 17:25:15.688 SERIAL » [ACK] (0x06) 17:25:15.689 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 4 │ destination: 4 └─[MultilevelSwitchCCReport] current value: 0 17:25:15.692 SERIAL » 0x010a0013220370050a258419 (12 bytes) 17:25:15.692 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 132 └─[ConfigurationCCGet] parameter #: 10 17:25:15.693 CNTRLR [Node 033] [~] [Multilevel Switch] interviewComplete: [Endpoint 4] [internal] true => true 17:25:15.693 CNTRLR [Node 033] MultilevelSwitchCC: doing a partial interview... [Endpoint 5] 17:25:15.693 CNTRLR » [Node 033] requesting current switch state... [Endpoint 5] 17:25:15.697 SERIAL « [ACK] (0x06) 17:25:15.700 SERIAL « 0x0104011301e8 (6 bytes) 17:25:15.701 SERIAL » [ACK] (0x06) 17:25:15.701 DRIVER « [RES] [SendData] was sent: true 17:25:15.721 SERIAL « 0x01070013840000036c (9 bytes) 17:25:15.721 SERIAL » [ACK] (0x06) 17:25:15.722 DRIVER « [REQ] [SendData] callback id: 132 transmit status: OK 17:25:15.736 SERIAL « 0x010b000400220570060a0100aa (13 bytes) 17:25:15.741 CNTRLR [Node 034] [~] [Configuration] 10: 0 => 0 17:25:15.742 SERIAL » [ACK] (0x06) 17:25:15.743 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 0 17:25:15.746 SERIAL » 0x010a00131f0370051f258530 (12 bytes) 17:25:15.747 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 133 └─[ConfigurationCCGet] parameter #: 31 17:25:15.748 CNTRLR « [Node 034] parameter #10 has value: 0 17:25:15.749 CNTRLR » [Node 034] querying parameter #11 value... 17:25:15.755 SERIAL « [ACK] (0x06) 17:25:15.756 SERIAL « 0x0104011301e8 (6 bytes) 17:25:15.757 SERIAL » [ACK] (0x06) 17:25:15.757 DRIVER « [RES] [SendData] was sent: true 17:25:15.773 SERIAL « 0x01070013850000026c (9 bytes) 17:25:15.773 SERIAL » [ACK] (0x06) 17:25:15.774 DRIVER « [REQ] [SendData] callback id: 133 transmit status: OK 17:25:15.784 SERIAL « 0x010b0004001f0570061f010280 (13 bytes) 17:25:15.789 CNTRLR [Node 031] [~] [Configuration] 31: 2 => 2 17:25:15.790 SERIAL » [ACK] (0x06) 17:25:15.791 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 2 17:25:15.794 SERIAL » 0x010d00132306600d0001810525868f (15 bytes) 17:25:15.794 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 134 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ClockCCGet] 17:25:15.794 CNTRLR « [Node 031] parameter #31 has value: 2 17:25:15.795 CNTRLR » [Node 031] querying parameter #32 value... 17:25:15.798 SERIAL « [ACK] (0x06) 17:25:15.802 SERIAL « 0x0104011301e8 (6 bytes) 17:25:15.803 SERIAL » [ACK] (0x06) 17:25:15.804 DRIVER « [RES] [SendData] was sent: true 17:25:15.860 SERIAL « 0x01070013860000076a (9 bytes) 17:25:15.860 SERIAL » [ACK] (0x06) 17:25:15.860 DRIVER « [REQ] [SendData] callback id: 134 transmit status: OK 17:25:15.942 SERIAL « 0x010e0004002308600d01008106721453 (16 bytes) 17:25:15.943 SERIAL » [ACK] (0x06) 17:25:15.944 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ClockCCReport] clock setting: Wednesday, 18:20 17:25:15.947 SERIAL » 0x010d00132106600d00052602258728 (15 bytes) 17:25:15.947 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 135 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 5 └─[MultilevelSwitchCCGet] 17:25:15.948 CNTRLR « [Node 035] received current clock setting: Wednesday, 18:20 17:25:15.948 CNTRLR [Node 035] [~] [Clock] interviewComplete: true => true [Endpoint 1] [internal] 17:25:15.979 SERIAL « [ACK] (0x06) 17:25:15.982 SERIAL « 0x0104011301e8 (6 bytes) 17:25:15.982 SERIAL » [ACK] (0x06) 17:25:15.983 DRIVER « [RES] [SendData] was sent: true 17:25:15.990 CNTRLR [Node 035] ZWavePlusCC: doing a partial interview... [Endpoint 2] 17:25:15.991 CNTRLR [Node 035] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue => true 17:25:15.992 CNTRLR [Node 035] MultilevelSensorCC: doing a partial interview... [Endpoint 2] 17:25:15.992 CNTRLR » [Node 035] querying Air temperature sensor reading... [Endpoint 2] 17:25:16.036 SERIAL « 0x010700138700000864 (9 bytes) 17:25:16.036 SERIAL » [ACK] (0x06) 17:25:16.037 DRIVER « [REQ] [SendData] callback id: 135 transmit status: OK 17:25:16.066 SERIAL « 0x010d0004002107600d050526030098 (15 bytes) 17:25:16.067 CNTRLR [Node 033] [~] [Multilevel Switch] currentValue: 0 => 0 [Endpoint 5] 17:25:16.067 SERIAL » [ACK] (0x06) 17:25:16.068 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 5 │ destination: 5 └─[MultilevelSwitchCCReport] current value: 0 17:25:16.071 SERIAL » 0x010a0013220370050b258814 (12 bytes) 17:25:16.072 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 136 └─[ConfigurationCCGet] parameter #: 11 17:25:16.072 CNTRLR [Node 033] [~] [Multilevel Switch] interviewComplete: [Endpoint 5] [internal] true => true 17:25:16.073 CNTRLR [Node 033] MultilevelSwitchCC: doing a partial interview... 17:25:16.073 CNTRLR » [Node 033] requesting current switch state... 17:25:16.076 SERIAL « [ACK] (0x06) 17:25:16.080 SERIAL « 0x0104011301e8 (6 bytes) 17:25:16.081 SERIAL » [ACK] (0x06) 17:25:16.081 DRIVER « [RES] [SendData] was sent: true 17:25:16.100 SERIAL « 0x010700138800000360 (9 bytes) 17:25:16.101 SERIAL » [ACK] (0x06) 17:25:16.101 DRIVER « [REQ] [SendData] callback id: 136 transmit status: OK 17:25:16.115 SERIAL « 0x010b000400220570060b0100ab (13 bytes) 17:25:16.120 CNTRLR [Node 034] [~] [Configuration] 11: 0 => 0 17:25:16.121 SERIAL » [ACK] (0x06) 17:25:16.122 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 11 value size: 1 value: 0 17:25:16.125 SERIAL » 0x010a00131f03700520258903 (12 bytes) 17:25:16.125 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 137 └─[ConfigurationCCGet] parameter #: 32 17:25:16.126 CNTRLR « [Node 034] parameter #11 has value: 0 17:25:16.126 CNTRLR » [Node 034] querying parameter #12 value... 17:25:16.131 SERIAL « [ACK] (0x06) 17:25:16.133 SERIAL « 0x0104011301e8 (6 bytes) 17:25:16.134 SERIAL » [ACK] (0x06) 17:25:16.134 DRIVER « [RES] [SendData] was sent: true 17:25:16.172 SERIAL « 0x010700138900000361 (9 bytes) 17:25:16.173 SERIAL » [ACK] (0x06) 17:25:16.173 DRIVER « [REQ] [SendData] callback id: 137 transmit status: OK 17:25:16.178 SERIAL « 0x010b0004001f057006200103be (13 bytes) 17:25:16.183 CNTRLR [Node 031] [~] [Configuration] 32: 3 => 3 17:25:16.184 SERIAL » [ACK] (0x06) 17:25:16.185 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 1 value: 3 17:25:16.188 SERIAL » 0x010f00132308600d000231040100258a3c (17 bytes) 17:25:16.189 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 138 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 17:25:16.189 CNTRLR « [Node 031] parameter #32 has value: 3 17:25:16.189 CNTRLR » [Node 031] querying parameter #33 value... 17:25:16.193 SERIAL « [ACK] (0x06) 17:25:16.198 SERIAL « 0x0104011301e8 (6 bytes) 17:25:16.199 SERIAL » [ACK] (0x06) 17:25:16.200 DRIVER « [RES] [SendData] was sent: true 17:25:16.256 SERIAL « 0x010700138a00000667 (9 bytes) 17:25:16.257 SERIAL » [ACK] (0x06) 17:25:16.257 DRIVER « [REQ] [SendData] callback id: 138 transmit status: OK 17:25:16.343 SERIAL « 0x0110000400230a600d02003105012200a41e (18 bytes) 17:25:16.345 CNTRLR [Node 035] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 17:25:16.346 CNTRLR [Node 035] [~] [Multilevel Sensor] Air temperature: 16.4 => 16.4 [Endpoint 2] 17:25:16.346 SERIAL » [ACK] (0x06) 17:25:16.348 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 16.4 17:25:16.355 SERIAL » 0x0109001321022602258b4c (11 bytes) 17:25:16.355 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 139 └─[MultilevelSwitchCCGet] 17:25:16.356 CNTRLR « [Node 035] received current Air temperature sensor reading: 16.4 [Endpoint 2] °C 17:25:16.356 CNTRLR [Node 035] [~] [Multilevel Sensor] interviewComplete: [Endpoint 2] [internal] true => true 17:25:16.396 SERIAL « [ACK] (0x06) 17:25:16.402 SERIAL « 0x0104011301e8 (6 bytes) 17:25:16.402 SERIAL » [ACK] (0x06) 17:25:16.405 DRIVER « [RES] [SendData] was sent: true 17:25:16.407 CNTRLR [Node 035] NotificationCC: doing a partial interview... [Endpoint 2] 17:25:16.408 CNTRLR » [Node 035] querying notification status for Power Management... [Endpoint 2] 17:25:16.435 SERIAL « 0x010700138b00000868 (9 bytes) 17:25:16.435 SERIAL » [ACK] (0x06) 17:25:16.436 DRIVER « [REQ] [SendData] callback id: 139 transmit status: OK 17:25:16.463 SERIAL « 0x01090004002103260300f5 (11 bytes) 17:25:16.464 CNTRLR [Node 033] [~] [Multilevel Switch] currentValue: 0 => 0 [Endpoint 0] 17:25:16.464 SERIAL » [ACK] (0x06) 17:25:16.465 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 0 17:25:16.468 SERIAL » 0x010a0013220370050c258c17 (12 bytes) 17:25:16.468 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 140 └─[ConfigurationCCGet] parameter #: 12 17:25:16.469 CNTRLR [Node 033] [~] [Multilevel Switch] interviewComplete: [Endpoint 0] [internal] true => true 17:25:16.469 CNTRLR [Node 033] MultilevelSensorCC: doing a partial interview... 17:25:16.469 CNTRLR » [Node 033] querying current sensor reading... 17:25:16.472 SERIAL « [ACK] (0x06) 17:25:16.476 SERIAL « 0x0104011301e8 (6 bytes) 17:25:16.476 SERIAL » [ACK] (0x06) 17:25:16.477 DRIVER « [RES] [SendData] was sent: true 17:25:16.497 SERIAL « 0x010700138c00000265 (9 bytes) 17:25:16.497 SERIAL » [ACK] (0x06) 17:25:16.498 DRIVER « [REQ] [SendData] callback id: 140 transmit status: OK 17:25:16.512 SERIAL « 0x010c000400220670060c02003299 (14 bytes) 17:25:16.517 CNTRLR [Node 034] [~] [Configuration] 12: 50 => 50 17:25:16.518 SERIAL » [ACK] (0x06) 17:25:16.519 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 50 17:25:16.522 SERIAL » 0x010a00131f03700521258d06 (12 bytes) 17:25:16.522 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 141 └─[ConfigurationCCGet] parameter #: 33 17:25:16.522 CNTRLR « [Node 034] parameter #12 has value: 50 17:25:16.523 CNTRLR » [Node 034] querying parameter #13 value... 17:25:16.528 SERIAL « [ACK] (0x06) 17:25:16.531 SERIAL « 0x0104011301e8 (6 bytes) 17:25:16.532 SERIAL » [ACK] (0x06) 17:25:16.532 DRIVER « [RES] [SendData] was sent: true 17:25:16.547 SERIAL « 0x010700138d00000264 (9 bytes) 17:25:16.548 SERIAL » [ACK] (0x06) 17:25:16.548 DRIVER « [REQ] [SendData] callback id: 141 transmit status: OK 17:25:16.583 SERIAL « 0x010b0004001f057006210101bd (13 bytes) 17:25:16.588 CNTRLR [Node 031] [~] [Configuration] 33: 1 => 1 17:25:16.589 SERIAL » [ACK] (0x06) 17:25:16.591 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 1 value: 1 17:25:16.595 SERIAL » 0x011000132309600d00027104000800258e6f (18 bytes) 17:25:16.595 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 142 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: Power Management 17:25:16.596 CNTRLR « [Node 031] parameter #33 has value: 1 17:25:16.596 CNTRLR » [Node 031] querying parameter #39 value... 17:25:16.600 SERIAL « [ACK] (0x06) 17:25:16.604 SERIAL « 0x0104011301e8 (6 bytes) 17:25:16.605 SERIAL » [ACK] (0x06) 17:25:16.605 DRIVER « [RES] [SendData] was sent: true 17:25:16.664 SERIAL « 0x010700138e00000762 (9 bytes) 17:25:16.664 SERIAL » [ACK] (0x06) 17:25:16.665 DRIVER « [REQ] [SendData] callback id: 142 transmit status: OK 17:25:16.755 SERIAL « 0x0113000400230d600d02007105000000ff08fe00d4 (21 bytes) 17:25:16.756 SERIAL » [ACK] (0x06) 17:25:16.757 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 17:25:16.760 SERIAL » 0x0109001321023104258f59 (11 bytes) 17:25:16.760 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 143 └─[MultilevelSensorCCGet] 17:25:16.761 CNTRLR [Node 035] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 2] 54 17:25:16.761 CNTRLR » [Node 035] querying notification status for System... [Endpoint 2] 17:25:16.765 SERIAL « [ACK] (0x06) 17:25:16.768 SERIAL « 0x0104011301e8 (6 bytes) 17:25:16.768 SERIAL » [ACK] (0x06) 17:25:16.769 DRIVER « [RES] [SendData] was sent: true 17:25:16.835 SERIAL « 0x010700138f00000763 (9 bytes) 17:25:16.836 SERIAL » [ACK] (0x06) 17:25:16.836 DRIVER « [REQ] [SendData] callback id: 143 transmit status: OK 17:25:16.846 SERIAL « 0x010c0004002106310504220000c2 (14 bytes) 17:25:16.847 CNTRLR [Node 033] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:25:16.848 CNTRLR [Node 033] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 17:25:16.848 SERIAL » [ACK] (0x06) 17:25:16.849 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:25:16.852 SERIAL » 0x010a0013220370050d25900a (12 bytes) 17:25:16.853 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 144 └─[ConfigurationCCGet] parameter #: 13 17:25:16.853 CNTRLR « [Node 033] received current sensor reading: sensor type: Power value: 0 W 17:25:16.853 CNTRLR [Node 033] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 17:25:16.880 SERIAL « [ACK] (0x06) 17:25:16.883 SERIAL « 0x0104011301e8 (6 bytes) 17:25:16.883 SERIAL » [ACK] (0x06) 17:25:16.885 DRIVER « [RES] [SendData] was sent: true 17:25:16.887 CNTRLR [Node 033] MeterCC: doing a partial interview... 17:25:16.887 CNTRLR » [Node 033] querying meter value (type = Electric, scale = kWh)... 17:25:16.889 SERIAL « 0x010700139000000378 (9 bytes) 17:25:16.890 SERIAL » [ACK] (0x06) 17:25:16.890 DRIVER « [REQ] [SendData] callback id: 144 transmit status: OK 17:25:16.896 SERIAL « 0x010c000400220670060d020005af (14 bytes) 17:25:16.902 CNTRLR [Node 034] [~] [Configuration] 13: 5 => 5 17:25:16.902 SERIAL » [ACK] (0x06) 17:25:16.903 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 2 value: 5 17:25:16.906 SERIAL » 0x010a00131f0370052725911c (12 bytes) 17:25:16.907 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 145 └─[ConfigurationCCGet] parameter #: 39 17:25:16.907 CNTRLR « [Node 034] parameter #13 has value: 5 17:25:16.908 CNTRLR » [Node 034] querying parameter #15 value... 17:25:16.911 SERIAL « [ACK] (0x06) 17:25:16.916 SERIAL « 0x0104011301e8 (6 bytes) 17:25:16.916 SERIAL » [ACK] (0x06) 17:25:16.917 DRIVER « [RES] [SendData] was sent: true 17:25:16.932 SERIAL « 0x010700139100000278 (9 bytes) 17:25:16.933 SERIAL » [ACK] (0x06) 17:25:16.933 DRIVER « [REQ] [SendData] callback id: 145 transmit status: OK 17:25:16.943 SERIAL « 0x010c0004001f06700627020258e7 (14 bytes) 17:25:16.948 CNTRLR [Node 031] [~] [Configuration] 39: 600 => 600 17:25:16.949 SERIAL » [ACK] (0x06) 17:25:16.950 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 39 value size: 2 value: 600 17:25:16.953 SERIAL » 0x011000132309600d00027104000900259272 (18 bytes) 17:25:16.954 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 146 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 17:25:16.954 CNTRLR « [Node 031] parameter #39 has value: 600 17:25:16.954 CNTRLR » [Node 031] querying parameter #40 value... 17:25:16.957 SERIAL « [ACK] (0x06) 17:25:16.966 SERIAL « 0x0104011301e8 (6 bytes) 17:25:16.967 SERIAL » [ACK] (0x06) 17:25:16.967 DRIVER « [RES] [SendData] was sent: true 17:25:17.020 SERIAL « 0x01070013920000077e (9 bytes) 17:25:17.021 SERIAL » [ACK] (0x06) 17:25:17.021 DRIVER « [REQ] [SendData] callback id: 146 transmit status: OK 17:25:17.059 SERIAL « 0x010c0004000306310504220546a3 (14 bytes) 17:25:17.060 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:25:17.060 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 111.7 => 135 [Endpoint 0] 17:25:17.061 SERIAL » [ACK] (0x06) 17:25:17.062 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 135 17:25:18.624 CNTRLR [Node 035] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 17:25:19.128 SERIAL » 0x011000132309600d00027104000900259272 (18 bytes) 17:25:19.132 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 146 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 17:25:19.142 SERIAL « [ACK] (0x06) 17:25:19.148 SERIAL « 0x0104011301e8 (6 bytes) 17:25:19.149 SERIAL » [ACK] (0x06) 17:25:19.149 DRIVER « [RES] [SendData] was sent: true 17:25:20.599 SERIAL « 0x0107001392000091e8 (9 bytes) 17:25:20.599 SERIAL » [ACK] (0x06) 17:25:20.600 DRIVER « [REQ] [SendData] callback id: 146 transmit status: OK 17:25:22.204 CNTRLR [Node 035] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 17:25:22.709 SERIAL » 0x011000132309600d00027104000900259272 (18 bytes) 17:25:22.709 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 146 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[NotificationCCGet] notification type: System 17:25:22.712 SERIAL « [ACK] (0x06) 17:25:22.719 SERIAL « 0x0104011301e8 (6 bytes) 17:25:22.719 SERIAL » [ACK] (0x06) 17:25:22.720 DRIVER « [RES] [SendData] was sent: true 17:25:24.099 SERIAL « 0x010700139200008bf2 (9 bytes) 17:25:24.099 SERIAL » [ACK] (0x06) 17:25:24.100 DRIVER « [REQ] [SendData] callback id: 146 transmit status: OK 17:25:24.198 SERIAL « 0x010c00040003063105042208a149 (14 bytes) 17:25:24.208 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:25:24.210 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 135 => 220.9 [Endpoint 0] 17:25:24.211 SERIAL » [ACK] (0x06) 17:25:24.212 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 220.9 17:25:25.710 SERIAL » 0x010a00132103320100259341 (12 bytes) 17:25:25.711 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 147 └─[MeterCCGet] duration: kWh 17:25:25.712 CNTRLR [Node 035] querying notification status for System timed out - sk [Endpoint 2] ipping because it is not critical... 17:25:25.713 CNTRLR [Node 035] [~] [Notification] interviewComplete: true [Endpoint 2] [internal] => true 17:25:25.777 SERIAL « [ACK] (0x06) 17:25:25.784 SERIAL « 0x0104011301e8 (6 bytes) 17:25:25.785 SERIAL » [ACK] (0x06) 17:25:25.787 DRIVER « [RES] [SendData] was sent: true 17:25:25.792 SERIAL « 0x01070013930000027a (9 bytes) 17:25:25.802 SERIAL » [ACK] (0x06) 17:25:25.805 CNTRLR [Node 035] BatteryCC: doing a partial interview... [Endpoint 2] 17:25:25.806 CNTRLR » [Node 035] querying battery status... [Endpoint 2] 17:25:25.809 DRIVER « [REQ] [SendData] callback id: 147 transmit status: OK 17:25:25.811 SERIAL « 0x0110000400210a3202214400000000000095 (18 bytes) 17:25:25.812 CNTRLR [Node 033] [~] [Meter] value[65537]: 0 => 0 [Endpoint 0] 17:25:25.813 CNTRLR [Node 033] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 17:25:25.813 SERIAL » [ACK] (0x06) 17:25:25.815 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 0 time delta: 0 seconds 17:25:25.822 SERIAL » 0x010a0013220370050f25940c (12 bytes) 17:25:25.823 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 148 └─[ConfigurationCCGet] parameter #: 15 17:25:25.823 CNTRLR » [Node 033] querying meter value (type = Electric, scale = W)... 17:25:25.827 SERIAL « [ACK] (0x06) 17:25:25.831 SERIAL « 0x0104011301e8 (6 bytes) 17:25:25.831 SERIAL » [ACK] (0x06) 17:25:25.832 DRIVER « [RES] [SendData] was sent: true 17:25:25.855 SERIAL « 0x01070013940000037c (9 bytes) 17:25:25.856 SERIAL » [ACK] (0x06) 17:25:25.857 DRIVER « [REQ] [SendData] callback id: 148 transmit status: OK 17:25:25.869 SERIAL « 0x010b000400220570060f0100af (13 bytes) 17:25:25.875 CNTRLR [Node 034] [~] [Configuration] 15: 0 => 0 17:25:25.876 SERIAL » [ACK] (0x06) 17:25:25.877 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 15 value size: 1 value: 0 17:25:25.880 SERIAL » 0x010a00131f03700528259517 (12 bytes) 17:25:25.880 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 149 └─[ConfigurationCCGet] parameter #: 40 17:25:25.881 CNTRLR « [Node 034] parameter #15 has value: 0 17:25:25.881 CNTRLR » [Node 034] querying parameter #16 value... 17:25:25.884 SERIAL « [ACK] (0x06) 17:25:25.889 SERIAL « 0x0104011301e8 (6 bytes) 17:25:25.890 SERIAL » [ACK] (0x06) 17:25:25.891 DRIVER « [RES] [SendData] was sent: true 17:25:25.906 SERIAL « 0x01070013950000027c (9 bytes) 17:25:25.906 SERIAL » [ACK] (0x06) 17:25:25.907 DRIVER « [REQ] [SendData] callback id: 149 transmit status: OK 17:25:25.917 SERIAL « 0x010b0004001f057006280103b6 (13 bytes) 17:25:25.922 CNTRLR [Node 031] [~] [Configuration] 40: 3 => 3 17:25:25.923 SERIAL » [ACK] (0x06) 17:25:25.924 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 3 17:25:25.927 SERIAL » 0x010d00132306600d0002800225969a (15 bytes) 17:25:25.927 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 150 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[BatteryCCGet] 17:25:25.927 CNTRLR « [Node 031] parameter #40 has value: 3 17:25:25.928 CNTRLR » [Node 031] querying parameter #41 value... 17:25:25.931 SERIAL « [ACK] (0x06) 17:25:25.936 SERIAL « 0x0104011301e8 (6 bytes) 17:25:25.937 SERIAL » [ACK] (0x06) 17:25:25.938 DRIVER « [RES] [SendData] was sent: true 17:25:25.992 SERIAL « 0x010c00040003063105042203b053 (14 bytes) 17:25:25.993 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:25:25.993 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 220.9 => 94.4 [Endpoint 0] 17:25:25.994 SERIAL » [ACK] (0x06) 17:25:25.995 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 94.4 17:25:27.437 SERIAL « 0x0107001396000096eb (9 bytes) 17:25:27.437 SERIAL » [ACK] (0x06) 17:25:27.439 DRIVER « [REQ] [SendData] callback id: 150 transmit status: OK 17:25:27.553 SERIAL « 0x010d0004002307600d02008003546a (15 bytes) 17:25:27.554 CNTRLR [Node 035] [~] [Battery] level: 84 => 84 [Endpoint 2] 17:25:27.554 CNTRLR [Node 035] [~] [Battery] isLow: false => false [Endpoint 2] 17:25:27.555 SERIAL » [ACK] (0x06) 17:25:27.556 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BatteryCCReport] level: 84 is low: false 17:25:27.559 SERIAL » 0x010a00132103320110259755 (12 bytes) 17:25:27.559 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 151 └─[MeterCCGet] duration: W 17:25:27.560 CNTRLR « [Node 035] received response for battery information: [Endpoint 2] level: 84 17:25:27.560 CNTRLR [Node 035] [~] [Battery] interviewComplete: true => tr [Endpoint 2] [internal] ue 17:25:27.588 SERIAL « [ACK] (0x06) 17:25:27.591 SERIAL « 0x0104011301e8 (6 bytes) 17:25:27.592 SERIAL » [ACK] (0x06) 17:25:27.593 DRIVER « [RES] [SendData] was sent: true 17:25:27.599 CNTRLR [Node 035] MultilevelSensorCC: doing a partial interview... 17:25:27.599 CNTRLR » [Node 035] querying Air temperature sensor reading... 17:25:27.646 SERIAL « 0x010700139700000874 (9 bytes) 17:25:27.646 SERIAL » [ACK] (0x06) 17:25:27.647 DRIVER « [REQ] [SendData] callback id: 151 transmit status: OK 17:25:27.657 SERIAL « 0x0110000400210a32022132000000000000e3 (18 bytes) 17:25:27.658 CNTRLR [Node 033] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 17:25:27.659 CNTRLR [Node 033] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 17:25:27.660 SERIAL » [ACK] (0x06) 17:25:27.662 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 17:25:27.665 SERIAL » 0x010a0013220370051025981f (12 bytes) 17:25:27.665 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 152 └─[ConfigurationCCGet] parameter #: 16 17:25:27.666 CNTRLR [Node 033] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 17:25:27.667 CNTRLR [Node 033] ColorSwitchCC: doing a partial interview... 17:25:27.674 CNTRLR » [Node 033] querying current color state (Warm White) 17:25:27.736 SERIAL « [ACK] (0x06) 17:25:27.738 SERIAL « 0x0104011301e8 (6 bytes) 17:25:27.738 SERIAL » [ACK] (0x06) 17:25:27.739 DRIVER « [RES] [SendData] was sent: true 17:25:27.741 SERIAL « 0x010700139800000370 (9 bytes) 17:25:27.742 SERIAL » [ACK] (0x06) 17:25:27.742 DRIVER « [REQ] [SendData] callback id: 152 transmit status: OK 17:25:27.745 SERIAL « 0x010b00040022057006100100b0 (13 bytes) 17:25:27.760 CNTRLR [Node 034] [~] [Configuration] 16: 0 => 0 17:25:27.761 SERIAL » [ACK] (0x06) 17:25:27.762 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 0 17:25:27.766 SERIAL » 0x010a00131f0370052925991a (12 bytes) 17:25:27.766 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 153 └─[ConfigurationCCGet] parameter #: 41 17:25:27.766 CNTRLR « [Node 034] parameter #16 has value: 0 17:25:27.767 CNTRLR » [Node 034] querying parameter #17 value... 17:25:27.770 SERIAL « [ACK] (0x06) 17:25:27.775 SERIAL « 0x0104011301e8 (6 bytes) 17:25:27.775 SERIAL » [ACK] (0x06) 17:25:27.776 DRIVER « [RES] [SendData] was sent: true 17:25:27.791 SERIAL « 0x010700139900000270 (9 bytes) 17:25:27.792 SERIAL » [ACK] (0x06) 17:25:27.792 DRIVER « [REQ] [SendData] callback id: 153 transmit status: OK 17:25:27.802 SERIAL « 0x010b0004001f057006290102b6 (13 bytes) 17:25:27.807 CNTRLR [Node 031] [~] [Configuration] 41: 2 => 2 17:25:27.808 SERIAL » [ACK] (0x06) 17:25:27.809 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 41 value size: 1 value: 2 17:25:27.812 SERIAL » 0x010b0013230431040100259a4b (13 bytes) 17:25:27.812 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 154 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 17:25:27.812 CNTRLR « [Node 031] parameter #41 has value: 2 17:25:27.813 CNTRLR » [Node 031] querying parameter #42 value... 17:25:27.816 SERIAL « [ACK] (0x06) 17:25:27.849 SERIAL « 0x0104011301e8 (6 bytes) 17:25:27.849 SERIAL » [ACK] (0x06) 17:25:27.850 DRIVER « [RES] [SendData] was sent: true 17:25:27.876 SERIAL « 0x010700139a00000677 (9 bytes) 17:25:27.877 SERIAL » [ACK] (0x06) 17:25:27.877 DRIVER « [REQ] [SendData] callback id: 154 transmit status: OK 17:25:27.961 SERIAL « 0x010c00040023063105012200a461 (14 bytes) 17:25:27.962 CNTRLR [Node 035] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 17:25:27.963 CNTRLR [Node 035] [~] [Multilevel Sensor] Air temperature: 18.1 => 16.4 [Endpoint 0] 17:25:27.963 SERIAL » [ACK] (0x06) 17:25:27.964 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 16.4 17:25:27.967 SERIAL » 0x010a00132103330300259b4a (12 bytes) 17:25:27.968 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 155 └─[ColorSwitchCCGet] color component: Warm White 17:25:27.968 CNTRLR « [Node 035] received current Air temperature sensor reading: 16.4 °C 17:25:27.968 CNTRLR [Node 035] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 17:25:27.969 CNTRLR [Node 035] ThermostatModeCC: doing a partial interview... 17:25:27.969 CNTRLR » [Node 035] querying current thermostat mode... 17:25:27.972 SERIAL « [ACK] (0x06) 17:25:27.976 SERIAL « 0x0104011301e8 (6 bytes) 17:25:27.976 SERIAL » [ACK] (0x06) 17:25:27.976 DRIVER « [RES] [SendData] was sent: true 17:25:28.055 SERIAL « 0x010700139b00000878 (9 bytes) 17:25:28.056 SERIAL » [ACK] (0x06) 17:25:28.056 DRIVER « [REQ] [SendData] callback id: 155 transmit status: OK 17:25:28.084 SERIAL « 0x010a000400210433040000e3 (12 bytes) 17:25:28.086 CNTRLR [Node 033] [~] [Color Switch] currentColor[0]: 0 => 0 [Endpoint 0] 17:25:28.086 SERIAL » [ACK] (0x06) 17:25:28.088 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ColorSwitchCCReport] color component: Warm White current value: 0 17:25:28.091 SERIAL » 0x010a00132203700511259c1a (12 bytes) 17:25:28.091 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 156 └─[ConfigurationCCGet] parameter #: 17 17:25:28.092 CNTRLR » [Node 033] querying current color state (Red) 17:25:28.095 SERIAL « [ACK] (0x06) 17:25:28.099 SERIAL « 0x0104011301e8 (6 bytes) 17:25:28.100 SERIAL » [ACK] (0x06) 17:25:28.100 DRIVER « [RES] [SendData] was sent: true 17:25:28.144 SERIAL « 0x010700139c00000374 (9 bytes) 17:25:28.144 SERIAL » [ACK] (0x06) 17:25:28.147 DRIVER « [REQ] [SendData] callback id: 156 transmit status: OK 17:25:28.150 SERIAL « 0x010c000400220670061102003284 (14 bytes) 17:25:28.156 CNTRLR [Node 034] [~] [Configuration] 17: 50 => 50 17:25:28.157 SERIAL » [ACK] (0x06) 17:25:28.158 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 17 value size: 2 value: 50 17:25:28.161 SERIAL » 0x010a00131f0370052a259d1d (12 bytes) 17:25:28.161 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 157 └─[ConfigurationCCGet] parameter #: 42 17:25:28.162 CNTRLR « [Node 034] parameter #17 has value: 50 17:25:28.162 CNTRLR » [Node 034] querying parameter #18 value... 17:25:28.165 SERIAL « [ACK] (0x06) 17:25:28.169 SERIAL « 0x0104011301e8 (6 bytes) 17:25:28.170 SERIAL » [ACK] (0x06) 17:25:28.170 DRIVER « [RES] [SendData] was sent: true 17:25:28.186 SERIAL « 0x010700139d00000274 (9 bytes) 17:25:28.187 SERIAL » [ACK] (0x06) 17:25:28.188 DRIVER « [REQ] [SendData] callback id: 157 transmit status: OK 17:25:28.197 SERIAL « 0x010b0004001f0570062a0103b4 (13 bytes) 17:25:28.203 CNTRLR [Node 031] [~] [Configuration] 42: 3 => 3 17:25:28.203 SERIAL » [ACK] (0x06) 17:25:28.205 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 3 17:25:28.208 SERIAL » 0x0109001323024002259e3d (11 bytes) 17:25:28.209 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 158 └─[ThermostatModeCCGet] 17:25:28.209 CNTRLR « [Node 031] parameter #42 has value: 3 17:25:28.210 CNTRLR » [Node 031] querying parameter #43 value... 17:25:28.213 SERIAL « [ACK] (0x06) 17:25:28.219 SERIAL « 0x0104011301e8 (6 bytes) 17:25:28.219 SERIAL » [ACK] (0x06) 17:25:28.221 DRIVER « [RES] [SendData] was sent: true 17:25:28.272 SERIAL « 0x010700139e00000673 (9 bytes) 17:25:28.273 SERIAL » [ACK] (0x06) 17:25:28.273 DRIVER « [REQ] [SendData] callback id: 158 transmit status: OK 17:25:28.350 SERIAL « 0x0109000400230340030190 (11 bytes) 17:25:28.352 CNTRLR [Node 035] [~] [Thermostat Mode] mode: 1 => 1 [Endpoint 0] 17:25:28.353 SERIAL » [ACK] (0x06) 17:25:28.354 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[ThermostatModeCCReport] mode: Heat 17:25:28.361 SERIAL » 0x010a00132103330302259f4c (12 bytes) 17:25:28.362 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 159 └─[ColorSwitchCCGet] color component: Red 17:25:28.363 CNTRLR « [Node 035] received current thermostat mode: Heat 17:25:28.364 CNTRLR [Node 035] [~] [Thermostat Mode] interviewComplete: tr [Endpoint 0] [internal] ue => true 17:25:28.422 SERIAL « [ACK] (0x06) 17:25:28.426 SERIAL « 0x0104011301e8 (6 bytes) 17:25:28.426 SERIAL » [ACK] (0x06) 17:25:28.427 DRIVER « [RES] [SendData] was sent: true 17:25:28.429 CNTRLR [Node 035] ThermostatSetpointCC: doing a partial interview... 17:25:28.430 CNTRLR » [Node 035] querying current value of setpoint Heating... 17:25:28.445 SERIAL « 0x010700139f0000087c (9 bytes) 17:25:28.446 SERIAL » [ACK] (0x06) 17:25:28.446 DRIVER « [REQ] [SendData] callback id: 159 transmit status: OK 17:25:28.474 SERIAL « 0x010a000400210433040200e1 (12 bytes) 17:25:28.484 CNTRLR [Node 033] [~] [Color Switch] currentColor[2]: 0 => 0 [Endpoint 0] 17:25:28.485 SERIAL » [ACK] (0x06) 17:25:28.488 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ColorSwitchCCReport] color component: Red current value: 0 17:25:28.491 SERIAL » 0x010a0013220370051225a025 (12 bytes) 17:25:28.492 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 160 └─[ConfigurationCCGet] parameter #: 18 17:25:28.492 CNTRLR » [Node 033] querying current color state (Green) 17:25:28.496 SERIAL « [ACK] (0x06) 17:25:28.500 SERIAL « 0x0104011301e8 (6 bytes) 17:25:28.500 SERIAL » [ACK] (0x06) 17:25:28.501 DRIVER « [RES] [SendData] was sent: true 17:25:28.521 SERIAL « 0x01070013a000000348 (9 bytes) 17:25:28.521 SERIAL » [ACK] (0x06) 17:25:28.521 DRIVER « [REQ] [SendData] callback id: 160 transmit status: OK 17:25:28.535 SERIAL « 0x010c0004002206700612020005b0 (14 bytes) 17:25:28.540 CNTRLR [Node 034] [~] [Configuration] 18: 5 => 5 17:25:28.541 SERIAL » [ACK] (0x06) 17:25:28.542 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 18 value size: 2 value: 5 17:25:28.545 SERIAL » 0x010a00131f0370052b25a120 (12 bytes) 17:25:28.545 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 161 └─[ConfigurationCCGet] parameter #: 43 17:25:28.546 CNTRLR « [Node 034] parameter #18 has value: 5 17:25:28.546 CNTRLR » [Node 034] querying parameter #20 value... 17:25:28.549 SERIAL « [ACK] (0x06) 17:25:28.553 SERIAL « 0x0104011301e8 (6 bytes) 17:25:28.554 SERIAL » [ACK] (0x06) 17:25:28.555 DRIVER « [RES] [SendData] was sent: true 17:25:28.571 SERIAL « 0x01070013a100000349 (9 bytes) 17:25:28.571 SERIAL » [ACK] (0x06) 17:25:28.571 DRIVER « [REQ] [SendData] callback id: 161 transmit status: OK 17:25:28.583 SERIAL « 0x010b0004001f0570062b0101b7 (13 bytes) 17:25:28.588 CNTRLR [Node 031] [~] [Configuration] 43: 1 => 1 17:25:28.589 SERIAL » [ACK] (0x06) 17:25:28.590 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 1 17:25:28.593 SERIAL » 0x010a0013230343020125a201 (12 bytes) 17:25:28.593 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 162 └─[ThermostatSetpointCCGet] setpoint type: Heating 17:25:28.593 CNTRLR « [Node 031] parameter #43 has value: 1 17:25:28.594 CNTRLR [Node 031] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:25:28.620 SERIAL « [ACK] (0x06) 17:25:28.621 SERIAL « 0x0104011301e8 (6 bytes) 17:25:28.622 SERIAL » [ACK] (0x06) 17:25:28.625 DRIVER « [RES] [SendData] was sent: true 17:25:28.628 CNTRLR [Node 031] MultiChannelAssociationCC: doing a partial interview... 17:25:28.628 CNTRLR » [Node 031] querying multi channel association group #1... 17:25:28.657 SERIAL « 0x01070013a20000064f (9 bytes) 17:25:28.657 SERIAL » [ACK] (0x06) 17:25:28.658 DRIVER « [REQ] [SendData] callback id: 162 transmit status: OK 17:25:28.741 SERIAL « 0x010c0004002306430301220064d5 (14 bytes) 17:25:28.742 CNTRLR [Node 035] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 0] 17:25:28.742 CNTRLR [Node 035] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 17:25:28.743 SERIAL » [ACK] (0x06) 17:25:28.743 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 17:25:28.746 SERIAL » 0x010a00131f038e020125a3f1 (12 bytes) 17:25:28.747 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 163 └─[MultiChannelAssociationCCGet] group id: 1 17:25:28.747 CNTRLR « [Node 035] received current value of setpoint Heating: 10 °C 17:25:28.747 CNTRLR [Node 035] [~] [Thermostat Setpoint] interviewComplete [Endpoint 0] [internal] : true => true 17:25:28.748 CNTRLR [Node 035] ConfigurationCC: Loading configuration parameters from device confi g 17:25:28.753 CNTRLR [Node 035] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:25:28.754 CNTRLR [Node 035] [Configuration] 1: metadata updated 17:25:28.755 CNTRLR [Node 035] [Configuration] 2: metadata updated 17:25:28.756 CNTRLR [Node 035] [Configuration] 3: metadata updated 17:25:28.757 CNTRLR [Node 035] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:25:28.757 CNTRLR » [Node 035] querying parameter #1 value... 17:25:28.760 SERIAL « [ACK] (0x06) 17:25:28.761 SERIAL « 0x0104011301e8 (6 bytes) 17:25:28.762 SERIAL » [ACK] (0x06) 17:25:28.762 DRIVER « [RES] [SendData] was sent: true 17:25:28.835 SERIAL « 0x01070013a300000840 (9 bytes) 17:25:28.835 SERIAL » [ACK] (0x06) 17:25:28.836 DRIVER « [REQ] [SendData] callback id: 163 transmit status: OK 17:25:28.846 SERIAL « 0x010b0004001f058e0301050063 (13 bytes) 17:25:28.846 SERIAL » [ACK] (0x06) 17:25:28.847 CNTRLR [Node 031] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 17:25:28.848 CNTRLR [Node 031] [~] [Multi Channel Association] nodeIds[1]: => 17:25:28.849 CNTRLR [Node 031] [~] [Multi Channel Association] endpoints[1]: => 17:25:28.850 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: endpoints: 17:25:28.853 SERIAL » 0x010a0013210333030325a476 (12 bytes) 17:25:28.853 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 164 └─[ColorSwitchCCGet] color component: Green 17:25:28.853 CNTRLR « [Node 031] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 17:25:28.854 CNTRLR » [Node 031] querying multi channel association group #2... 17:25:28.857 SERIAL « [ACK] (0x06) 17:25:28.861 SERIAL « 0x0104011301e8 (6 bytes) 17:25:28.861 SERIAL » [ACK] (0x06) 17:25:28.862 DRIVER « [RES] [SendData] was sent: true 17:25:28.879 SERIAL « 0x01070013a40000034c (9 bytes) 17:25:28.879 SERIAL » [ACK] (0x06) 17:25:28.880 DRIVER « [REQ] [SendData] callback id: 164 transmit status: OK 17:25:28.936 SERIAL « 0x010a000400210433040300e0 (12 bytes) 17:25:28.937 CNTRLR [Node 033] [~] [Color Switch] currentColor[3]: 0 => 0 [Endpoint 0] 17:25:28.937 SERIAL » [ACK] (0x06) 17:25:28.938 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ColorSwitchCCReport] color component: Green current value: 0 17:25:28.941 SERIAL » 0x010a00131f038e020225a5f4 (12 bytes) 17:25:28.942 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 165 └─[MultiChannelAssociationCCGet] group id: 2 17:25:28.942 CNTRLR » [Node 033] querying current color state (Blue) 17:25:28.946 SERIAL « [ACK] (0x06) 17:25:28.950 SERIAL « 0x0104011301e8 (6 bytes) 17:25:28.950 SERIAL » [ACK] (0x06) 17:25:28.951 DRIVER « [RES] [SendData] was sent: true 17:25:28.967 SERIAL « 0x01070013a50000024c (9 bytes) 17:25:28.968 SERIAL » [ACK] (0x06) 17:25:28.968 DRIVER « [REQ] [SendData] callback id: 165 transmit status: OK 17:25:28.978 SERIAL « 0x010b0004001f058e0302050060 (13 bytes) 17:25:28.979 SERIAL » [ACK] (0x06) 17:25:28.980 CNTRLR [Node 031] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 17:25:28.982 CNTRLR [Node 031] [~] [Multi Channel Association] nodeIds[2]: => 17:25:28.983 CNTRLR [Node 031] [~] [Multi Channel Association] endpoints[2]: => 17:25:28.984 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 17:25:28.988 SERIAL » 0x010a0013220370051425a625 (12 bytes) 17:25:28.988 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 166 └─[ConfigurationCCGet] parameter #: 20 17:25:28.989 CNTRLR « [Node 031] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 17:25:28.989 CNTRLR » [Node 031] querying additional non-multi-channel association groups... 17:25:28.989 CNTRLR » [Node 031] querying association group #3... 17:25:28.993 SERIAL « [ACK] (0x06) 17:25:28.998 SERIAL « 0x0104011301e8 (6 bytes) 17:25:28.998 SERIAL » [ACK] (0x06) 17:25:28.999 DRIVER « [RES] [SendData] was sent: true 17:25:29.017 SERIAL « 0x01070013a60000024f (9 bytes) 17:25:29.017 SERIAL » [ACK] (0x06) 17:25:29.018 DRIVER « [REQ] [SendData] callback id: 166 transmit status: OK 17:25:29.031 SERIAL « 0x010b00040022057006140102b6 (13 bytes) 17:25:29.037 CNTRLR [Node 034] [~] [Configuration] 20: 2 => 2 17:25:29.038 SERIAL » [ACK] (0x06) 17:25:29.039 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 2 17:25:29.042 SERIAL » 0x010a00131f0385020325a7fc (12 bytes) 17:25:29.043 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 167 └─[AssociationCCGet] group id: 3 17:25:29.043 CNTRLR « [Node 034] parameter #20 has value: 2 17:25:29.043 CNTRLR » [Node 034] querying parameter #21 value... 17:25:29.048 SERIAL « [ACK] (0x06) 17:25:29.051 SERIAL « 0x0104011301e8 (6 bytes) 17:25:29.051 SERIAL » [ACK] (0x06) 17:25:29.052 DRIVER « [RES] [SendData] was sent: true 17:25:29.068 SERIAL « 0x01070013a70000024e (9 bytes) 17:25:29.068 SERIAL » [ACK] (0x06) 17:25:29.069 DRIVER « [REQ] [SendData] callback id: 167 transmit status: OK 17:25:29.079 SERIAL « 0x010c0004001f068503030100016b (14 bytes) 17:25:29.079 SERIAL » [ACK] (0x06) 17:25:29.080 CNTRLR [Node 031] [~] [Association] maxNodes[3]: 1 => 1 [internal] 17:25:29.080 CNTRLR [Node 031] [~] [Association] nodeIds[3]: 1 => 1 [internal] 17:25:29.081 DRIVER « [Node 031] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 17:25:29.083 SERIAL » 0x010a0013230370050125a83f (12 bytes) 17:25:29.084 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 168 └─[ConfigurationCCGet] parameter #: 1 17:25:29.084 CNTRLR « [Node 031] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 17:25:29.085 CNTRLR [Node 031] [~] [Association] hasLifeline: true => true [internal] 17:25:29.085 CNTRLR [Node 031] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:25:29.085 CNTRLR [Node 031] Interview stage completed: CommandClasses 17:25:29.085 CNTRLR [Node 031] Interview stage completed: OverwriteConfig 17:25:29.085 CNTRLR » [Node 031] requesting node neighbors... 17:25:29.088 SERIAL « [ACK] (0x06) 17:25:29.092 SERIAL « 0x0104011301e8 (6 bytes) 17:25:29.092 SERIAL » [ACK] (0x06) 17:25:29.092 DRIVER « [RES] [SendData] was sent: true 17:25:29.150 SERIAL « 0x01070013a800000645 (9 bytes) 17:25:29.150 SERIAL » [ACK] (0x06) 17:25:29.151 DRIVER « [REQ] [SendData] callback id: 168 transmit status: OK 17:25:29.232 SERIAL « 0x010e0004002308700601040000003c91 (16 bytes) 17:25:29.240 CNTRLR [Node 035] [~] [Configuration] 1: 60 => 60 17:25:29.241 SERIAL » [ACK] (0x06) 17:25:29.243 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 4 value: 60 17:25:29.255 SERIAL » 0x010700801f00000067 (9 bytes) 17:25:29.256 DRIVER » [Node 031] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:25:29.256 CNTRLR « [Node 035] parameter #1 has value: 60 17:25:29.256 CNTRLR » [Node 035] querying parameter #2 value... 17:25:29.302 SERIAL « [ACK] (0x06) 17:25:29.304 SERIAL « 0x012001806579ec0b0700000000000000000000000000000000000000000000000 (34 bytes) 0a2 17:25:29.304 SERIAL » [ACK] (0x06) 17:25:29.306 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 9, 12, 13, 14, 15, 19, 20, 22, 23, 24, 25, 26, 28, 33, 34, 35 17:25:29.314 SERIAL » 0x010a0013210333030425a97c (12 bytes) 17:25:29.315 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 169 └─[ColorSwitchCCGet] color component: Blue 17:25:29.315 CNTRLR « [Node 031] node neighbors received: 1, 3, 6, 7, 9, 12, 13, 14, 15, 19, 20, 2 2, 23, 24, 25, 26, 28, 33, 34, 35 17:25:29.316 CNTRLR [Node 031] Interview stage completed: Neighbors 17:25:29.316 CNTRLR [Node 031] Interview completed 17:25:29.323 SERIAL « [ACK] (0x06) 17:25:29.325 SERIAL « 0x0104011301e8 (6 bytes) 17:25:29.325 SERIAL » [ACK] (0x06) 17:25:29.326 DRIVER « [RES] [SendData] was sent: true 17:25:29.341 SERIAL « 0x01070013a900000341 (9 bytes) 17:25:29.341 SERIAL » [ACK] (0x06) 17:25:29.341 DRIVER « [REQ] [SendData] callback id: 169 transmit status: OK 17:25:29.369 SERIAL « 0x010a000400210433040400e7 (12 bytes) 17:25:29.369 CNTRLR [Node 033] [~] [Color Switch] currentColor[4]: 0 => 0 [Endpoint 0] 17:25:29.370 SERIAL » [ACK] (0x06) 17:25:29.371 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ColorSwitchCCReport] color component: Blue current value: 0 17:25:29.374 SERIAL » 0x010a0013220370051525aa28 (12 bytes) 17:25:29.374 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 170 └─[ConfigurationCCGet] parameter #: 21 17:25:29.375 CNTRLR [Node 033] [~] [Color Switch] interviewComplete: true [Endpoint 0] [internal] => true 17:25:29.375 CNTRLR [Node 033] ConfigurationCC: Loading configuration parameters from device confi g 17:25:29.381 CNTRLR [Node 033] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:25:29.382 CNTRLR [Node 033] [Configuration] 1: metadata updated 17:25:29.383 CNTRLR [Node 033] [Configuration] 6: metadata updated 17:25:29.384 CNTRLR [Node 033] [Configuration] 8: metadata updated 17:25:29.386 CNTRLR [Node 033] [Configuration] 9: metadata updated 17:25:29.387 CNTRLR [Node 033] [Configuration] 10: metadata updated 17:25:29.388 CNTRLR [Node 033] [Configuration] 11: metadata updated 17:25:29.389 CNTRLR [Node 033] [Configuration] 12: metadata updated 17:25:29.390 CNTRLR [Node 033] [Configuration] 13: metadata updated 17:25:29.391 CNTRLR [Node 033] [Configuration] 14: metadata updated 17:25:29.392 CNTRLR [Node 033] [Configuration] 16: metadata updated 17:25:29.394 CNTRLR [Node 033] [Configuration] 30: metadata updated 17:25:29.395 CNTRLR [Node 033] [Configuration] 38: metadata updated 17:25:29.396 CNTRLR [Node 033] [Configuration] 39: metadata updated 17:25:29.397 CNTRLR [Node 033] [Configuration] 42: metadata updated 17:25:29.398 CNTRLR [Node 033] [Configuration] 43: metadata updated 17:25:29.399 CNTRLR [Node 033] [Configuration] 44: metadata updated 17:25:29.400 CNTRLR [Node 033] [Configuration] 45: metadata updated 17:25:29.402 CNTRLR [Node 033] [Configuration] 71: metadata updated 17:25:29.403 CNTRLR [Node 033] [Configuration] 72: metadata updated 17:25:29.404 CNTRLR [Node 033] [Configuration] 73: metadata updated 17:25:29.406 CNTRLR [Node 033] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:25:29.406 CNTRLR » [Node 033] querying parameter #1 value... 17:25:29.413 SERIAL « [ACK] (0x06) 17:25:29.414 SERIAL « 0x0104011301e8 (6 bytes) 17:25:29.414 SERIAL » [ACK] (0x06) 17:25:29.415 DRIVER « [RES] [SendData] was sent: true 17:25:29.418 SERIAL « 0x01070013aa00000342 (9 bytes) 17:25:29.418 SERIAL » [ACK] (0x06) 17:25:29.421 DRIVER « [REQ] [SendData] callback id: 170 transmit status: OK 17:25:29.427 SERIAL « 0x010b00040022057006150100b5 (13 bytes) 17:25:29.433 CNTRLR [Node 034] [~] [Configuration] 21: 0 => 0 17:25:29.435 SERIAL » [ACK] (0x06) 17:25:29.436 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 21 value size: 1 value: 0 17:25:29.440 SERIAL » 0x010a0013230370050225ab3f (12 bytes) 17:25:29.440 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 171 └─[ConfigurationCCGet] parameter #: 2 17:25:29.441 CNTRLR « [Node 034] parameter #21 has value: 0 17:25:29.441 CNTRLR » [Node 034] querying parameter #27 value... 17:25:29.447 SERIAL « [ACK] (0x06) 17:25:29.449 SERIAL « 0x0104011301e8 (6 bytes) 17:25:29.449 SERIAL » [ACK] (0x06) 17:25:29.457 DRIVER « [RES] [SendData] was sent: true 17:25:29.521 SERIAL « 0x01070013ab00000646 (9 bytes) 17:25:29.521 SERIAL » [ACK] (0x06) 17:25:29.525 DRIVER « [REQ] [SendData] callback id: 171 transmit status: OK 17:25:29.593 SERIAL « 0x010e00040023087006020400000001af (16 bytes) 17:25:29.598 CNTRLR [Node 035] [~] [Configuration] 2: 1 => 1 17:25:29.598 SERIAL » [ACK] (0x06) 17:25:29.599 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 4 value: 1 17:25:29.602 SERIAL » 0x010a0013210370050125ac39 (12 bytes) 17:25:29.603 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 172 └─[ConfigurationCCGet] parameter #: 1 17:25:29.603 CNTRLR « [Node 035] parameter #2 has value: 1 17:25:29.603 CNTRLR » [Node 035] querying parameter #3 value... 17:25:29.608 SERIAL « [ACK] (0x06) 17:25:29.611 SERIAL « 0x0104011301e8 (6 bytes) 17:25:29.611 SERIAL » [ACK] (0x06) 17:25:29.613 DRIVER « [RES] [SendData] was sent: true 17:25:29.636 SERIAL « 0x01070013ac00000344 (9 bytes) 17:25:29.637 SERIAL » [ACK] (0x06) 17:25:29.637 DRIVER « [REQ] [SendData] callback id: 172 transmit status: OK 17:25:29.647 SERIAL « 0x010b000400210570060101ff5d (13 bytes) 17:25:29.652 CNTRLR [Node 033] [~] [Configuration] 1: 255 => 255 17:25:29.653 SERIAL » [ACK] (0x06) 17:25:29.654 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 255 17:25:29.664 SERIAL » 0x010a0013220370051b25ad21 (12 bytes) 17:25:29.664 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 173 └─[ConfigurationCCGet] parameter #: 27 17:25:29.665 CNTRLR « [Node 033] parameter #1 has value: 255 17:25:29.665 CNTRLR » [Node 033] querying parameter #6 value... 17:25:29.669 SERIAL « [ACK] (0x06) 17:25:29.673 SERIAL « 0x0104011301e8 (6 bytes) 17:25:29.673 SERIAL » [ACK] (0x06) 17:25:29.674 DRIVER « [RES] [SendData] was sent: true 17:25:29.693 SERIAL « 0x01070013ad00000345 (9 bytes) 17:25:29.693 SERIAL » [ACK] (0x06) 17:25:29.694 DRIVER « [REQ] [SendData] callback id: 173 transmit status: OK 17:25:29.707 SERIAL « 0x010b000400220570061b010fb4 (13 bytes) 17:25:29.713 CNTRLR [Node 034] [~] [Configuration] 27: 15 => 15 17:25:29.713 SERIAL » [ACK] (0x06) 17:25:29.714 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 27 value size: 1 value: 15 17:25:29.717 SERIAL » 0x010a0013230370050325ae3b (12 bytes) 17:25:29.718 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 174 └─[ConfigurationCCGet] parameter #: 3 17:25:29.718 CNTRLR « [Node 034] parameter #27 has value: 15 17:25:29.718 CNTRLR » [Node 034] querying parameter #28 value... 17:25:29.722 SERIAL « [ACK] (0x06) 17:25:29.726 SERIAL « 0x0104011301e8 (6 bytes) 17:25:29.726 SERIAL » [ACK] (0x06) 17:25:29.727 DRIVER « [RES] [SendData] was sent: true 17:25:29.781 SERIAL « 0x01070013ae00000643 (9 bytes) 17:25:29.782 SERIAL » [ACK] (0x06) 17:25:29.782 DRIVER « [REQ] [SendData] callback id: 174 transmit status: OK 17:25:29.864 SERIAL « 0x010e00040023087006030400000001ae (16 bytes) 17:25:29.869 CNTRLR [Node 035] [~] [Configuration] 3: 1 => 1 17:25:29.870 SERIAL » [ACK] (0x06) 17:25:29.871 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 4 value: 1 17:25:29.874 SERIAL » 0x010a0013210370050625af3d (12 bytes) 17:25:29.874 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 175 └─[ConfigurationCCGet] parameter #: 6 17:25:29.874 CNTRLR « [Node 035] parameter #3 has value: 1 17:25:29.875 CNTRLR [Node 035] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:25:29.909 SERIAL « [ACK] (0x06) 17:25:29.910 SERIAL « 0x0104011301e8 (6 bytes) 17:25:29.911 SERIAL » [ACK] (0x06) 17:25:29.912 DRIVER « [RES] [SendData] was sent: true 17:25:29.915 CNTRLR [Node 035] ProtectionCC: doing a partial interview... 17:25:29.916 CNTRLR » [Node 035] querying protection status... 17:25:29.919 SERIAL « 0x010c00040003063105042208b45c (14 bytes) 17:25:29.919 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:25:29.920 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 94.4 => 222.8 [Endpoint 0] 17:25:29.920 SERIAL » [ACK] (0x06) 17:25:29.921 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 222.8 17:25:29.947 SERIAL « 0x010c00040003063105042208b45c (14 bytes) 17:25:29.948 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:25:29.948 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 222.8 => 222.8 [Endpoint 0] 17:25:29.948 SERIAL » [ACK] (0x06) 17:25:29.949 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 222.8 17:25:29.982 SERIAL « 0x01070013af00000a4e (9 bytes) 17:25:29.983 SERIAL » [ACK] (0x06) 17:25:29.983 DRIVER « [REQ] [SendData] callback id: 175 transmit status: OK 17:25:29.993 SERIAL « 0x010b00040021057006060101a4 (13 bytes) 17:25:29.999 CNTRLR [Node 033] [~] [Configuration] 6: 1 => 1 17:25:29.999 SERIAL » [ACK] (0x06) 17:25:30.000 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 1 value: 1 17:25:30.007 SERIAL » 0x010a0013220370051c25b03b (12 bytes) 17:25:30.008 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 176 └─[ConfigurationCCGet] parameter #: 28 17:25:30.008 CNTRLR « [Node 033] parameter #6 has value: 1 17:25:30.008 CNTRLR » [Node 033] querying parameter #8 value... 17:25:30.012 SERIAL « [ACK] (0x06) 17:25:30.017 SERIAL « 0x0104011301e8 (6 bytes) 17:25:30.017 SERIAL » [ACK] (0x06) 17:25:30.019 DRIVER « [RES] [SendData] was sent: true 17:25:30.036 SERIAL « 0x01070013b000000259 (9 bytes) 17:25:30.037 SERIAL » [ACK] (0x06) 17:25:30.037 DRIVER « [REQ] [SendData] callback id: 176 transmit status: OK 17:25:30.051 SERIAL « 0x010b000400220570061c0100bc (13 bytes) 17:25:30.058 CNTRLR [Node 034] [~] [Configuration] 28: 0 => 0 17:25:30.059 SERIAL » [ACK] (0x06) 17:25:30.060 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 28 value size: 1 value: 0 17:25:30.073 SERIAL » 0x010900132302750225b127 (11 bytes) 17:25:30.073 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 177 └─[ProtectionCCGet] 17:25:30.074 CNTRLR « [Node 034] parameter #28 has value: 0 17:25:30.074 CNTRLR » [Node 034] querying parameter #29 value... 17:25:30.079 SERIAL « [ACK] (0x06) 17:25:30.081 SERIAL « 0x0104011301e8 (6 bytes) 17:25:30.082 SERIAL » [ACK] (0x06) 17:25:30.084 DRIVER « [RES] [SendData] was sent: true 17:25:30.137 SERIAL « 0x01070013b10000065c (9 bytes) 17:25:30.137 SERIAL » [ACK] (0x06) 17:25:30.138 DRIVER « [REQ] [SendData] callback id: 177 transmit status: OK 17:25:30.220 SERIAL « 0x01090004002303750300a4 (11 bytes) 17:25:30.221 CNTRLR [Node 035] [~] [Protection] local: 0 => 0 [Endpoint 0] 17:25:30.221 SERIAL » [ACK] (0x06) 17:25:30.222 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected 17:25:30.227 SERIAL » 0x010a0013210370050825b22e (12 bytes) 17:25:30.227 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 178 └─[ConfigurationCCGet] parameter #: 8 17:25:30.228 CNTRLR « [Node 035] received protection status: local: Unprotected 17:25:30.229 CNTRLR [Node 035] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 17:25:30.280 SERIAL « [ACK] (0x06) 17:25:30.285 SERIAL « 0x0104011301e8 (6 bytes) 17:25:30.286 SERIAL » [ACK] (0x06) 17:25:30.287 DRIVER « [RES] [SendData] was sent: true 17:25:30.291 CNTRLR [Node 035] ClockCC: doing a partial interview... 17:25:30.292 CNTRLR » [Node 035] requesting current clock setting... 17:25:30.315 SERIAL « 0x01070013b200000851 (9 bytes) 17:25:30.316 SERIAL » [ACK] (0x06) 17:25:30.317 DRIVER « [REQ] [SendData] callback id: 178 transmit status: OK 17:25:30.345 SERIAL « 0x010b00040021057006080100ab (13 bytes) 17:25:30.352 CNTRLR [Node 033] [~] [Configuration] 8: 0 => 0 17:25:30.353 SERIAL » [ACK] (0x06) 17:25:30.376 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 0 17:25:30.381 SERIAL » 0x010a0013220370051d25b339 (12 bytes) 17:25:30.381 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 179 └─[ConfigurationCCGet] parameter #: 29 17:25:30.389 CNTRLR « [Node 033] parameter #8 has value: 0 17:25:30.389 CNTRLR » [Node 033] querying parameter #9 value... 17:25:30.403 SERIAL « [ACK] (0x06) 17:25:30.404 SERIAL « 0x0104011301e8 (6 bytes) 17:25:30.405 SERIAL » [ACK] (0x06) 17:25:30.407 DRIVER « [RES] [SendData] was sent: true 17:25:30.421 SERIAL « 0x01070013b30000025a (9 bytes) 17:25:30.422 SERIAL » [ACK] (0x06) 17:25:30.422 DRIVER « [REQ] [SendData] callback id: 179 transmit status: OK 17:25:30.431 SERIAL « 0x010b000400220570061d0100bd (13 bytes) 17:25:30.436 CNTRLR [Node 034] [~] [Configuration] 29: 0 => 0 17:25:30.437 SERIAL » [ACK] (0x06) 17:25:30.438 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 29 value size: 1 value: 0 17:25:30.442 SERIAL » 0x010900132302810525b4d1 (11 bytes) 17:25:30.442 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 180 └─[ClockCCGet] 17:25:30.443 CNTRLR « [Node 034] parameter #29 has value: 0 17:25:30.443 CNTRLR » [Node 034] querying parameter #30 value... 17:25:30.447 SERIAL « [ACK] (0x06) 17:25:30.456 SERIAL « 0x0104011301e8 (6 bytes) 17:25:30.456 SERIAL » [ACK] (0x06) 17:25:30.459 DRIVER « [RES] [SendData] was sent: true 17:25:30.506 SERIAL « 0x01070013b400000659 (9 bytes) 17:25:30.506 SERIAL » [ACK] (0x06) 17:25:30.507 DRIVER « [REQ] [SendData] callback id: 180 transmit status: OK 17:25:30.590 SERIAL « 0x010a00040023048106721437 (12 bytes) 17:25:30.591 SERIAL » [ACK] (0x06) 17:25:30.592 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[ClockCCReport] clock setting: Wednesday, 18:20 17:25:30.597 SERIAL » 0x010a0013210370050925b528 (12 bytes) 17:25:30.597 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 181 └─[ConfigurationCCGet] parameter #: 9 17:25:30.598 CNTRLR « [Node 035] received current clock setting: Wednesday, 18:20 17:25:30.598 CNTRLR [Node 035] [~] [Clock] interviewComplete: true => true [Endpoint 0] [internal] 17:25:30.631 SERIAL « [ACK] (0x06) 17:25:30.635 SERIAL « 0x0104011301e8 (6 bytes) 17:25:30.636 SERIAL » [ACK] (0x06) 17:25:30.637 DRIVER « [RES] [SendData] was sent: true 17:25:30.641 CNTRLR [Node 035] AssociationCC: doing a partial interview... 17:25:30.642 CNTRLR [Node 035] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:25:30.642 CNTRLR [Node 035] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:25:30.643 CNTRLR [Node 035] MultiChannelAssociationCC: doing a partial interview... 17:25:30.643 CNTRLR » [Node 035] querying multi channel association group #1... 17:25:30.675 SERIAL « 0x01070013b500000759 (9 bytes) 17:25:30.676 SERIAL » [ACK] (0x06) 17:25:30.676 DRIVER « [REQ] [SendData] callback id: 181 transmit status: OK 17:25:30.686 SERIAL « 0x010b00040021057006090101ab (13 bytes) 17:25:30.691 CNTRLR [Node 033] [~] [Configuration] 9: 1 => 1 17:25:30.692 SERIAL » [ACK] (0x06) 17:25:30.692 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 1 value: 1 17:25:30.695 SERIAL » 0x010a001323038e020125b6d8 (12 bytes) 17:25:30.696 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 182 └─[MultiChannelAssociationCCGet] group id: 1 17:25:30.696 CNTRLR « [Node 033] parameter #9 has value: 1 17:25:30.696 CNTRLR » [Node 033] querying parameter #10 value... 17:25:30.700 SERIAL « [ACK] (0x06) 17:25:30.704 SERIAL « 0x0104011301e8 (6 bytes) 17:25:30.704 SERIAL » [ACK] (0x06) 17:25:30.705 DRIVER « [RES] [SendData] was sent: true 17:25:30.761 SERIAL « 0x01070013b60000065b (9 bytes) 17:25:30.761 SERIAL » [ACK] (0x06) 17:25:30.761 DRIVER « [REQ] [SendData] callback id: 182 transmit status: OK 17:25:30.842 SERIAL « 0x010e00040023088e0301010000010052 (16 bytes) 17:25:30.843 SERIAL » [ACK] (0x06) 17:25:30.844 CNTRLR [Node 035] [~] [Multi Channel Association] maxNodes[1]: 1 => 1 17:25:30.845 CNTRLR [Node 035] [~] [Multi Channel Association] nodeIds[1]: => 17:25:30.846 CNTRLR [Node 035] [~] [Multi Channel Association] endpoints[1]: [object Object] => [o bject Object] 17:25:30.847 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 1 node ids: endpoints: 1:0 17:25:30.850 SERIAL » 0x010a0013220370051e25b73e (12 bytes) 17:25:30.851 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 183 └─[ConfigurationCCGet] parameter #: 30 17:25:30.851 CNTRLR « [Node 035] received information for multi channel association group #1: maximum # of nodes: 1 currently assigned nodes: currently assigned endpoints: 1:0 17:25:30.851 CNTRLR [Node 035] [~] [Association] hasLifeline: true => true [internal] 17:25:30.852 CNTRLR [Node 035] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:25:30.852 CNTRLR [Node 035] AssociationGroupInfoCC: doing a partial interview... 17:25:30.852 CNTRLR [Node 035] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 17:25:30.853 CNTRLR [Node 035] NotificationCC: doing a partial interview... 17:25:30.853 CNTRLR » [Node 035] querying notification status for Power Management... 17:25:30.857 SERIAL « [ACK] (0x06) 17:25:30.860 SERIAL « 0x0104011301e8 (6 bytes) 17:25:30.861 SERIAL » [ACK] (0x06) 17:25:30.862 DRIVER « [RES] [SendData] was sent: true 17:25:30.938 SERIAL « 0x01070013b700000854 (9 bytes) 17:25:30.939 SERIAL » [ACK] (0x06) 17:25:30.939 DRIVER « [REQ] [SendData] callback id: 183 transmit status: OK 17:25:30.952 SERIAL « 0x010b000400220570061e0100be (13 bytes) 17:25:30.958 CNTRLR [Node 034] [~] [Configuration] 30: 0 => 0 17:25:30.959 SERIAL » [ACK] (0x06) 17:25:30.960 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 0 17:25:30.966 SERIAL » 0x010a0013210370050a25b826 (12 bytes) 17:25:30.967 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 184 └─[ConfigurationCCGet] parameter #: 10 17:25:30.967 CNTRLR « [Node 034] parameter #30 has value: 0 17:25:30.967 CNTRLR » [Node 034] querying parameter #31 value... 17:25:30.971 SERIAL « [ACK] (0x06) 17:25:30.975 SERIAL « 0x0104011301e8 (6 bytes) 17:25:30.975 SERIAL » [ACK] (0x06) 17:25:30.976 DRIVER « [RES] [SendData] was sent: true 17:25:30.992 SERIAL « 0x01070013b800000251 (9 bytes) 17:25:30.993 SERIAL » [ACK] (0x06) 17:25:30.993 DRIVER « [REQ] [SendData] callback id: 184 transmit status: OK 17:25:31.056 SERIAL « 0x010c000400210670060a02000aa4 (14 bytes) 17:25:31.062 CNTRLR [Node 033] [~] [Configuration] 10: 10 => 10 17:25:31.063 SERIAL » [ACK] (0x06) 17:25:31.065 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 2 value: 10 17:25:31.072 SERIAL » 0x010c00132305710400080025b927 (14 bytes) 17:25:31.073 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 185 └─[NotificationCCGet] notification type: Power Management 17:25:31.073 CNTRLR « [Node 033] parameter #10 has value: 10 17:25:31.073 CNTRLR » [Node 033] querying parameter #11 value... 17:25:31.076 SERIAL « [ACK] (0x06) 17:25:31.082 SERIAL « 0x0104011301e8 (6 bytes) 17:25:31.083 SERIAL » [ACK] (0x06) 17:25:31.083 DRIVER « [RES] [SendData] was sent: true 17:25:31.141 SERIAL « 0x01070013b900000755 (9 bytes) 17:25:31.141 SERIAL » [ACK] (0x06) 17:25:31.142 DRIVER « [REQ] [SendData] callback id: 185 transmit status: OK 17:25:31.223 SERIAL « 0x010f00040023097105000000ff08fe00a3 (17 bytes) 17:25:31.224 SERIAL » [ACK] (0x06) 17:25:31.225 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0xfe) 17:25:31.228 SERIAL » 0x010a0013220370051f25ba32 (12 bytes) 17:25:31.229 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 186 └─[ConfigurationCCGet] parameter #: 31 17:25:31.230 CNTRLR [Node 035] [~] [Notification] Power Management[unknown]: 254 => 2 [Endpoint 0] 54 17:25:31.230 CNTRLR » [Node 035] querying notification status for System... 17:25:31.234 SERIAL « [ACK] (0x06) 17:25:31.237 SERIAL « 0x0104011301e8 (6 bytes) 17:25:31.237 SERIAL » [ACK] (0x06) 17:25:31.238 DRIVER « [RES] [SendData] was sent: true 17:25:31.318 SERIAL « 0x01070013ba00000859 (9 bytes) 17:25:31.318 SERIAL » [ACK] (0x06) 17:25:31.319 DRIVER « [REQ] [SendData] callback id: 186 transmit status: OK 17:25:31.333 SERIAL « 0x010c000400220670061f0200ff47 (14 bytes) 17:25:31.338 CNTRLR [Node 034] [~] [Configuration] 31: 255 => 255 17:25:31.339 SERIAL » [ACK] (0x06) 17:25:31.340 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 2 value: 255 17:25:31.343 SERIAL » 0x010a0013210370050b25bb24 (12 bytes) 17:25:31.343 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 187 └─[ConfigurationCCGet] parameter #: 11 17:25:31.344 CNTRLR « [Node 034] parameter #31 has value: 255 17:25:31.344 CNTRLR » [Node 034] querying parameter #32 value... 17:25:31.347 SERIAL « [ACK] (0x06) 17:25:31.351 SERIAL « 0x0104011301e8 (6 bytes) 17:25:31.352 SERIAL » [ACK] (0x06) 17:25:31.352 DRIVER « [RES] [SendData] was sent: true 17:25:31.369 SERIAL « 0x01070013bb00000353 (9 bytes) 17:25:31.370 SERIAL » [ACK] (0x06) 17:25:31.370 DRIVER « [REQ] [SendData] callback id: 187 transmit status: OK 17:25:31.380 SERIAL « 0x010b000400210570060b0143eb (13 bytes) 17:25:31.385 CNTRLR [Node 033] [~] [Configuration] 11: 67 => 67 17:25:31.386 SERIAL » [ACK] (0x06) 17:25:31.387 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 11 value size: 1 value: 67 17:25:31.392 SERIAL » 0x010c00132305710400090025bc23 (14 bytes) 17:25:31.392 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 188 └─[NotificationCCGet] notification type: System 17:25:31.393 CNTRLR « [Node 033] parameter #11 has value: 67 17:25:31.393 CNTRLR » [Node 033] querying parameter #12 value... 17:25:31.397 SERIAL « [ACK] (0x06) 17:25:31.401 SERIAL « 0x0104011301e8 (6 bytes) 17:25:31.402 SERIAL » [ACK] (0x06) 17:25:31.403 DRIVER « [RES] [SendData] was sent: true 17:25:31.459 SERIAL « 0x01070013bc00000750 (9 bytes) 17:25:31.459 SERIAL » [ACK] (0x06) 17:25:31.460 DRIVER « [REQ] [SendData] callback id: 188 transmit status: OK 17:25:31.543 SERIAL « 0x010f00040023097105000000ff09fe00a2 (17 bytes) 17:25:31.543 SERIAL » [ACK] (0x06) 17:25:31.544 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: System notification status: 255 notification event: Unknown (0xfe) 17:25:31.547 SERIAL » 0x010a0013220370052025bd0a (12 bytes) 17:25:31.547 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 189 └─[ConfigurationCCGet] parameter #: 32 17:25:31.548 CNTRLR [Node 035] [~] [Notification] System[unknown]: 254 => 254 [Endpoint 0] 17:25:31.548 CNTRLR [Node 035] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 17:25:31.574 SERIAL « [ACK] (0x06) 17:25:31.575 SERIAL « 0x0104011301e8 (6 bytes) 17:25:31.575 SERIAL » [ACK] (0x06) 17:25:31.576 DRIVER « [RES] [SendData] was sent: true 17:25:31.599 SERIAL « 0x01090004000803300300ca (11 bytes) 17:25:31.600 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:25:31.600 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:25:31.600 SERIAL » [ACK] (0x06) 17:25:31.601 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:25:31.671 SERIAL « 0x01070013bd00000c5a (9 bytes) 17:25:31.672 SERIAL » [ACK] (0x06) 17:25:31.672 DRIVER « [REQ] [SendData] callback id: 189 transmit status: OK 17:25:31.686 SERIAL « 0x010c000400220670062002000087 (14 bytes) 17:25:31.699 CNTRLR [Node 034] [~] [Configuration] 32: 0 => 0 17:25:31.700 SERIAL » [ACK] (0x06) 17:25:31.701 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 2 value: 0 17:25:31.704 SERIAL » 0x010a0013210370050c25be26 (12 bytes) 17:25:31.705 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 190 └─[ConfigurationCCGet] parameter #: 12 17:25:31.705 CNTRLR « [Node 034] parameter #32 has value: 0 17:25:31.706 CNTRLR » [Node 034] querying parameter #33 value... 17:25:31.709 SERIAL « [ACK] (0x06) 17:25:31.715 SERIAL « 0x0104011301e8 (6 bytes) 17:25:31.716 SERIAL » [ACK] (0x06) 17:25:31.717 DRIVER « [RES] [SendData] was sent: true 17:25:31.731 SERIAL « 0x01070013be00000356 (9 bytes) 17:25:31.731 SERIAL » [ACK] (0x06) 17:25:31.731 DRIVER « [REQ] [SendData] callback id: 190 transmit status: OK 17:25:31.741 SERIAL « 0x010b000400210570060c01ff50 (13 bytes) 17:25:31.746 CNTRLR [Node 033] [~] [Configuration] 12: 255 => 255 17:25:31.747 SERIAL » [ACK] (0x06) 17:25:31.747 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 1 value: 255 17:25:31.750 SERIAL » 0x010a0013220370052125bf09 (12 bytes) 17:25:31.750 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 191 └─[ConfigurationCCGet] parameter #: 33 17:25:31.751 CNTRLR « [Node 033] parameter #12 has value: 255 17:25:31.751 CNTRLR » [Node 033] querying parameter #13 value... 17:25:31.754 SERIAL « [ACK] (0x06) 17:25:31.758 SERIAL « 0x0104011301e8 (6 bytes) 17:25:31.759 SERIAL » [ACK] (0x06) 17:25:31.759 DRIVER « [RES] [SendData] was sent: true 17:25:31.779 SERIAL « 0x01070013bf00000357 (9 bytes) 17:25:31.779 SERIAL » [ACK] (0x06) 17:25:31.780 DRIVER « [REQ] [SendData] callback id: 191 transmit status: OK 17:25:31.794 SERIAL « 0x010c0004002206700621020063e5 (14 bytes) 17:25:31.799 CNTRLR [Node 034] [~] [Configuration] 33: 99 => 99 17:25:31.799 SERIAL » [ACK] (0x06) 17:25:31.800 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 2 value: 99 17:25:31.803 SERIAL » 0x010a0013210370050d25c059 (12 bytes) 17:25:31.803 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 192 └─[ConfigurationCCGet] parameter #: 13 17:25:31.804 CNTRLR « [Node 034] parameter #33 has value: 99 17:25:31.804 CNTRLR » [Node 034] querying parameter #35 value... 17:25:31.807 SERIAL « [ACK] (0x06) 17:25:31.813 SERIAL « 0x0104011301e8 (6 bytes) 17:25:31.813 SERIAL » [ACK] (0x06) 17:25:31.814 DRIVER « [RES] [SendData] was sent: true 17:25:31.829 SERIAL « 0x01070013c000000328 (9 bytes) 17:25:31.829 SERIAL » [ACK] (0x06) 17:25:31.830 DRIVER « [REQ] [SendData] callback id: 192 transmit status: OK 17:25:31.839 SERIAL « 0x010b000400210570060d0102ac (13 bytes) 17:25:31.844 CNTRLR [Node 033] [~] [Configuration] 13: 2 => 2 17:25:31.845 SERIAL » [ACK] (0x06) 17:25:31.846 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 2 17:25:31.859 SERIAL » 0x010a0013220370052325c175 (12 bytes) 17:25:31.859 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 193 └─[ConfigurationCCGet] parameter #: 35 17:25:31.860 CNTRLR « [Node 033] parameter #13 has value: 2 17:25:31.860 CNTRLR » [Node 033] querying parameter #14 value... 17:25:31.863 SERIAL « [ACK] (0x06) 17:25:31.868 SERIAL « 0x0104011301e8 (6 bytes) 17:25:31.869 SERIAL » [ACK] (0x06) 17:25:31.870 DRIVER « [RES] [SendData] was sent: true 17:25:31.888 SERIAL « 0x01070013c100000228 (9 bytes) 17:25:31.888 SERIAL » [ACK] (0x06) 17:25:31.889 DRIVER « [REQ] [SendData] callback id: 193 transmit status: OK 17:25:31.902 SERIAL « 0x010b0004002205700623010083 (13 bytes) 17:25:31.907 CNTRLR [Node 034] [~] [Configuration] 35: 0 => 0 17:25:31.908 SERIAL » [ACK] (0x06) 17:25:31.909 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 0 17:25:31.912 SERIAL » 0x010a0013210370050e25c258 (12 bytes) 17:25:31.915 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 194 └─[ConfigurationCCGet] parameter #: 14 17:25:31.915 CNTRLR « [Node 034] parameter #35 has value: 0 17:25:31.916 CNTRLR » [Node 034] querying parameter #36 value... 17:25:31.919 SERIAL « [ACK] (0x06) 17:25:31.923 SERIAL « 0x0104011301e8 (6 bytes) 17:25:31.924 SERIAL » [ACK] (0x06) 17:25:31.925 DRIVER « [RES] [SendData] was sent: true 17:25:31.941 SERIAL « 0x01070013c20000032a (9 bytes) 17:25:31.941 SERIAL » [ACK] (0x06) 17:25:31.942 DRIVER « [REQ] [SendData] callback id: 194 transmit status: OK 17:25:31.951 SERIAL « 0x010c000400210670060e021111aa (14 bytes) 17:25:31.956 CNTRLR [Node 033] [~] [Configuration] 14: 4369 => 4369 17:25:31.957 SERIAL » [ACK] (0x06) 17:25:31.958 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 2 value: 4369 17:25:31.961 SERIAL » 0x010a0013220370052425c370 (12 bytes) 17:25:31.961 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 195 └─[ConfigurationCCGet] parameter #: 36 17:25:31.961 CNTRLR « [Node 033] parameter #14 has value: 4369 17:25:31.962 CNTRLR » [Node 033] querying parameter #16 value... 17:25:31.965 SERIAL « [ACK] (0x06) 17:25:31.972 SERIAL « 0x0104011301e8 (6 bytes) 17:25:31.972 SERIAL » [ACK] (0x06) 17:25:31.973 DRIVER « [RES] [SendData] was sent: true 17:25:31.990 SERIAL « 0x01070013c30000032b (9 bytes) 17:25:31.990 SERIAL » [ACK] (0x06) 17:25:31.991 DRIVER « [REQ] [SendData] callback id: 195 transmit status: OK 17:25:32.004 SERIAL « 0x010c00040022067006240200ff7c (14 bytes) 17:25:32.009 CNTRLR [Node 034] [~] [Configuration] 36: 255 => 255 17:25:32.010 SERIAL » [ACK] (0x06) 17:25:32.011 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 36 value size: 2 value: 255 17:25:32.014 SERIAL » 0x010a0013210370051025c440 (12 bytes) 17:25:32.014 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 196 └─[ConfigurationCCGet] parameter #: 16 17:25:32.014 CNTRLR « [Node 034] parameter #36 has value: 255 17:25:32.015 CNTRLR » [Node 034] querying parameter #37 value... 17:25:32.018 SERIAL « [ACK] (0x06) 17:25:32.024 SERIAL « 0x0104011301e8 (6 bytes) 17:25:32.024 SERIAL » [ACK] (0x06) 17:25:32.025 DRIVER « [RES] [SendData] was sent: true 17:25:32.040 SERIAL « 0x01070013c40000032c (9 bytes) 17:25:32.040 SERIAL » [ACK] (0x06) 17:25:32.041 DRIVER « [REQ] [SendData] callback id: 196 transmit status: OK 17:25:32.050 SERIAL « 0x010b00040021057006100101b2 (13 bytes) 17:25:32.055 CNTRLR [Node 033] [~] [Configuration] 16: 1 => 1 17:25:32.056 SERIAL » [ACK] (0x06) 17:25:32.057 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 1 17:25:32.059 SERIAL » 0x010a0013220370052525c577 (12 bytes) 17:25:32.060 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 197 └─[ConfigurationCCGet] parameter #: 37 17:25:32.060 CNTRLR « [Node 033] parameter #16 has value: 1 17:25:32.060 CNTRLR » [Node 033] querying parameter #30 value... 17:25:32.063 SERIAL « [ACK] (0x06) 17:25:32.068 SERIAL « 0x0104011301e8 (6 bytes) 17:25:32.069 SERIAL » [ACK] (0x06) 17:25:32.070 DRIVER « [RES] [SendData] was sent: true 17:25:32.088 SERIAL « 0x01070013c50000032d (9 bytes) 17:25:32.089 SERIAL » [ACK] (0x06) 17:25:32.089 DRIVER « [REQ] [SendData] callback id: 197 transmit status: OK 17:25:32.103 SERIAL « 0x010c000400220670062502000082 (14 bytes) 17:25:32.108 CNTRLR [Node 034] [~] [Configuration] 37: 0 => 0 17:25:32.109 SERIAL » [ACK] (0x06) 17:25:32.109 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 37 value size: 2 value: 0 17:25:32.112 SERIAL » 0x010a0013210370051e25c64c (12 bytes) 17:25:32.113 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 198 └─[ConfigurationCCGet] parameter #: 30 17:25:32.113 CNTRLR « [Node 034] parameter #37 has value: 0 17:25:32.113 CNTRLR » [Node 034] querying parameter #38 value... 17:25:32.118 SERIAL « [ACK] (0x06) 17:25:32.123 SERIAL « 0x0104011301e8 (6 bytes) 17:25:32.123 SERIAL » [ACK] (0x06) 17:25:32.125 DRIVER « [RES] [SendData] was sent: true 17:25:32.128 CNTRLR [Node 035] Interview stage completed: CommandClasses 17:25:32.128 CNTRLR [Node 035] Interview stage completed: OverwriteConfig 17:25:32.128 CNTRLR » [Node 035] requesting node neighbors... 17:25:32.138 SERIAL « 0x01070013c60000022f (9 bytes) 17:25:32.138 SERIAL » [ACK] (0x06) 17:25:32.139 DRIVER « [REQ] [SendData] callback id: 198 transmit status: OK 17:25:32.148 SERIAL « 0x010b000400210570061e0100bd (13 bytes) 17:25:32.153 CNTRLR [Node 033] [~] [Configuration] 30: 0 => 0 17:25:32.154 SERIAL » [ACK] (0x06) 17:25:32.155 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 0 17:25:32.158 SERIAL » 0x01070080230000005b (9 bytes) 17:25:32.158 DRIVER » [Node 035] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:25:32.158 CNTRLR « [Node 033] parameter #30 has value: 0 17:25:32.159 CNTRLR » [Node 033] querying parameter #38 value... 17:25:32.162 SERIAL « [ACK] (0x06) 17:25:32.163 SERIAL « 0x0120018005f1ec590300000000000000000000000000000000000000000000000 (34 bytes) 01c 17:25:32.163 SERIAL » [ACK] (0x06) 17:25:32.164 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 9, 13, 14, 15, 16, 19, 20, 22, 23, 24, 25, 28, 29, 31, 33, 3 4 17:25:32.170 SERIAL » 0x010a0013220370052625c776 (12 bytes) 17:25:32.171 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 199 └─[ConfigurationCCGet] parameter #: 38 17:25:32.171 CNTRLR « [Node 035] node neighbors received: 1, 3, 9, 13, 14, 15, 16, 19, 20, 22, 23, 24, 25, 28, 29, 31, 33, 34 17:25:32.171 CNTRLR [Node 035] Interview stage completed: Neighbors 17:25:32.171 CNTRLR [Node 035] Interview completed 17:25:32.176 SERIAL « [ACK] (0x06) 17:25:32.179 SERIAL « 0x0104011301e8 (6 bytes) 17:25:32.180 SERIAL » [ACK] (0x06) 17:25:32.180 DRIVER « [RES] [SendData] was sent: true 17:25:32.199 SERIAL « 0x01070013c70000032f (9 bytes) 17:25:32.200 SERIAL » [ACK] (0x06) 17:25:32.200 DRIVER « [REQ] [SendData] callback id: 199 transmit status: OK 17:25:32.214 SERIAL « 0x010c0004002206700626020063e2 (14 bytes) 17:25:32.219 CNTRLR [Node 034] [~] [Configuration] 38: 99 => 99 17:25:32.220 SERIAL » [ACK] (0x06) 17:25:32.220 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 38 value size: 2 value: 99 17:25:32.223 SERIAL » 0x010a0013210370052625c87a (12 bytes) 17:25:32.224 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 200 └─[ConfigurationCCGet] parameter #: 38 17:25:32.224 CNTRLR « [Node 034] parameter #38 has value: 99 17:25:32.224 CNTRLR » [Node 034] querying parameter #40 value... 17:25:32.228 SERIAL « [ACK] (0x06) 17:25:32.233 SERIAL « 0x0104011301e8 (6 bytes) 17:25:32.233 SERIAL » [ACK] (0x06) 17:25:32.234 DRIVER « [RES] [SendData] was sent: true 17:25:32.249 SERIAL « 0x01070013c800000320 (9 bytes) 17:25:32.250 SERIAL » [ACK] (0x06) 17:25:32.250 DRIVER « [REQ] [SendData] callback id: 200 transmit status: OK 17:25:32.260 SERIAL « 0x010b0004002105700626010a8f (13 bytes) 17:25:32.265 CNTRLR [Node 033] [~] [Configuration] 38: 10 => 10 17:25:32.266 SERIAL » [ACK] (0x06) 17:25:32.267 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 38 value size: 1 value: 10 17:25:32.269 SERIAL » 0x010a0013220370052825c976 (12 bytes) 17:25:32.270 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 201 └─[ConfigurationCCGet] parameter #: 40 17:25:32.270 CNTRLR « [Node 033] parameter #38 has value: 10 17:25:32.270 CNTRLR » [Node 033] querying parameter #39 value... 17:25:32.273 SERIAL « [ACK] (0x06) 17:25:32.311 SERIAL « 0x0104011301e8 (6 bytes) 17:25:32.311 SERIAL » [ACK] (0x06) 17:25:32.312 DRIVER « [RES] [SendData] was sent: true 17:25:32.314 SERIAL « 0x01070013c900000321 (9 bytes) 17:25:32.314 SERIAL » [ACK] (0x06) 17:25:32.315 DRIVER « [REQ] [SendData] callback id: 201 transmit status: OK 17:25:32.318 SERIAL « 0x010b000400220570062801038b (13 bytes) 17:25:32.323 CNTRLR [Node 034] [~] [Configuration] 40: 3 => 3 17:25:32.324 SERIAL » [ACK] (0x06) 17:25:32.324 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 3 17:25:32.327 SERIAL » 0x010a0013210370052725ca79 (12 bytes) 17:25:32.328 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 202 └─[ConfigurationCCGet] parameter #: 39 17:25:32.328 CNTRLR « [Node 034] parameter #40 has value: 3 17:25:32.328 CNTRLR » [Node 034] querying parameter #41 value... 17:25:32.332 SERIAL « [ACK] (0x06) 17:25:32.336 SERIAL « 0x0104011301e8 (6 bytes) 17:25:32.337 SERIAL » [ACK] (0x06) 17:25:32.337 DRIVER « [RES] [SendData] was sent: true 17:25:32.353 SERIAL « 0x01070013ca00000223 (9 bytes) 17:25:32.354 SERIAL » [ACK] (0x06) 17:25:32.354 DRIVER « [REQ] [SendData] callback id: 202 transmit status: OK 17:25:32.364 SERIAL « 0x010c0004002106700627020258d9 (14 bytes) 17:25:32.369 CNTRLR [Node 033] [~] [Configuration] 39: 600 => 600 17:25:32.370 SERIAL » [ACK] (0x06) 17:25:32.371 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 39 value size: 2 value: 600 17:25:32.374 SERIAL » 0x010a0013220370052925cb75 (12 bytes) 17:25:32.374 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 203 └─[ConfigurationCCGet] parameter #: 41 17:25:32.375 CNTRLR « [Node 033] parameter #39 has value: 600 17:25:32.375 CNTRLR » [Node 033] querying parameter #42 value... 17:25:32.378 SERIAL « [ACK] (0x06) 17:25:32.382 SERIAL « 0x0104011301e8 (6 bytes) 17:25:32.383 SERIAL » [ACK] (0x06) 17:25:32.384 DRIVER « [RES] [SendData] was sent: true 17:25:32.403 SERIAL « 0x01070013cb00000323 (9 bytes) 17:25:32.403 SERIAL » [ACK] (0x06) 17:25:32.404 DRIVER « [REQ] [SendData] callback id: 203 transmit status: OK 17:25:32.417 SERIAL « 0x010b000400220570062901028b (13 bytes) 17:25:32.422 CNTRLR [Node 034] [~] [Configuration] 41: 2 => 2 17:25:32.424 SERIAL » [ACK] (0x06) 17:25:32.424 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 41 value size: 1 value: 2 17:25:32.427 SERIAL » 0x010a0013210370052a25cc72 (12 bytes) 17:25:32.428 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 204 └─[ConfigurationCCGet] parameter #: 42 17:25:32.428 CNTRLR « [Node 034] parameter #41 has value: 2 17:25:32.428 CNTRLR » [Node 034] querying parameter #42 value... 17:25:32.434 SERIAL « [ACK] (0x06) 17:25:32.438 SERIAL « 0x0104011301e8 (6 bytes) 17:25:32.438 SERIAL » [ACK] (0x06) 17:25:32.440 DRIVER « [RES] [SendData] was sent: true 17:25:32.453 SERIAL « 0x01070013cc00000225 (9 bytes) 17:25:32.453 SERIAL » [ACK] (0x06) 17:25:32.454 DRIVER « [REQ] [SendData] callback id: 204 transmit status: OK 17:25:32.463 SERIAL « 0x010b000400210570062a010089 (13 bytes) 17:25:32.470 CNTRLR [Node 033] [~] [Configuration] 42: 0 => 0 17:25:32.472 SERIAL » [ACK] (0x06) 17:25:32.472 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 0 17:25:32.476 SERIAL » 0x010a0013220370052a25cd70 (12 bytes) 17:25:32.477 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 205 └─[ConfigurationCCGet] parameter #: 42 17:25:32.477 CNTRLR « [Node 033] parameter #42 has value: 0 17:25:32.477 CNTRLR » [Node 033] querying parameter #43 value... 17:25:32.481 SERIAL « [ACK] (0x06) 17:25:32.488 SERIAL « 0x0104011301e8 (6 bytes) 17:25:32.488 SERIAL » [ACK] (0x06) 17:25:32.490 DRIVER « [RES] [SendData] was sent: true 17:25:32.505 SERIAL « 0x01070013cd00000224 (9 bytes) 17:25:32.506 SERIAL » [ACK] (0x06) 17:25:32.507 DRIVER « [REQ] [SendData] callback id: 205 transmit status: OK 17:25:32.523 SERIAL « 0x010b000400220570062a010389 (13 bytes) 17:25:32.531 CNTRLR [Node 034] [~] [Configuration] 42: 3 => 3 17:25:32.532 SERIAL » [ACK] (0x06) 17:25:32.533 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 3 17:25:32.537 SERIAL » 0x010a0013210370052b25ce71 (12 bytes) 17:25:32.538 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 206 └─[ConfigurationCCGet] parameter #: 43 17:25:32.538 CNTRLR « [Node 034] parameter #42 has value: 3 17:25:32.539 CNTRLR » [Node 034] querying parameter #43 value... 17:25:32.544 SERIAL « [ACK] (0x06) 17:25:32.547 SERIAL « 0x0104011301e8 (6 bytes) 17:25:32.548 SERIAL » [ACK] (0x06) 17:25:32.550 DRIVER « [RES] [SendData] was sent: true 17:25:32.564 SERIAL « 0x01070013ce00000227 (9 bytes) 17:25:32.564 SERIAL » [ACK] (0x06) 17:25:32.565 DRIVER « [REQ] [SendData] callback id: 206 transmit status: OK 17:25:32.574 SERIAL « 0x010b000400210570062b01058d (13 bytes) 17:25:32.579 CNTRLR [Node 033] [~] [Configuration] 43: 5 => 5 17:25:32.580 SERIAL » [ACK] (0x06) 17:25:32.581 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 5 17:25:32.584 SERIAL » 0x010a0013220370052b25cf73 (12 bytes) 17:25:32.584 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 207 └─[ConfigurationCCGet] parameter #: 43 17:25:32.584 CNTRLR « [Node 033] parameter #43 has value: 5 17:25:32.584 CNTRLR » [Node 033] querying parameter #44 value... 17:25:32.588 SERIAL « [ACK] (0x06) 17:25:32.594 SERIAL « 0x0104011301e8 (6 bytes) 17:25:32.594 SERIAL » [ACK] (0x06) 17:25:32.598 DRIVER « [RES] [SendData] was sent: true 17:25:32.612 SERIAL « 0x01070013cf00000327 (9 bytes) 17:25:32.613 SERIAL » [ACK] (0x06) 17:25:32.613 DRIVER « [REQ] [SendData] callback id: 207 transmit status: OK 17:25:32.627 SERIAL « 0x010b000400220570062b01018a (13 bytes) 17:25:32.632 CNTRLR [Node 034] [~] [Configuration] 43: 1 => 1 17:25:32.633 SERIAL » [ACK] (0x06) 17:25:32.634 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 1 17:25:32.637 SERIAL » 0x010a0013210370052c25d068 (12 bytes) 17:25:32.638 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 208 └─[ConfigurationCCGet] parameter #: 44 17:25:32.638 CNTRLR « [Node 034] parameter #43 has value: 1 17:25:32.638 CNTRLR » [Node 034] querying parameter #44 value... 17:25:32.642 SERIAL « [ACK] (0x06) 17:25:32.647 SERIAL « 0x0104011301e8 (6 bytes) 17:25:32.648 SERIAL » [ACK] (0x06) 17:25:32.649 DRIVER « [RES] [SendData] was sent: true 17:25:32.664 SERIAL « 0x01070013d000000239 (9 bytes) 17:25:32.664 SERIAL » [ACK] (0x06) 17:25:32.665 DRIVER « [REQ] [SendData] callback id: 208 transmit status: OK 17:25:32.674 SERIAL « 0x010c000400210670062c02001e96 (14 bytes) 17:25:32.679 CNTRLR [Node 033] [~] [Configuration] 44: 30 => 30 17:25:32.680 SERIAL » [ACK] (0x06) 17:25:32.681 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 44 value size: 2 value: 30 17:25:32.684 SERIAL » 0x010a0013220370052c25d16a (12 bytes) 17:25:32.684 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 209 └─[ConfigurationCCGet] parameter #: 44 17:25:32.685 CNTRLR « [Node 033] parameter #44 has value: 30 17:25:32.685 CNTRLR » [Node 033] querying parameter #45 value... 17:25:32.688 SERIAL « [ACK] (0x06) 17:25:32.693 SERIAL « 0x0104011301e8 (6 bytes) 17:25:32.693 SERIAL » [ACK] (0x06) 17:25:32.694 DRIVER « [RES] [SendData] was sent: true 17:25:32.713 SERIAL « 0x01070013d100000339 (9 bytes) 17:25:32.713 SERIAL » [ACK] (0x06) 17:25:32.714 DRIVER « [REQ] [SendData] callback id: 209 transmit status: OK 17:25:32.727 SERIAL « 0x010c000400220670062c020258d1 (14 bytes) 17:25:32.733 CNTRLR [Node 034] [~] [Configuration] 44: 600 => 600 17:25:32.733 SERIAL » [ACK] (0x06) 17:25:32.734 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 44 value size: 2 value: 600 17:25:32.737 SERIAL » 0x010a0013210370052d25d26b (12 bytes) 17:25:32.737 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 210 └─[ConfigurationCCGet] parameter #: 45 17:25:32.738 CNTRLR « [Node 034] parameter #44 has value: 600 17:25:32.738 CNTRLR » [Node 034] querying parameter #50 value... 17:25:32.741 SERIAL « [ACK] (0x06) 17:25:32.745 SERIAL « 0x0104011301e8 (6 bytes) 17:25:32.746 SERIAL » [ACK] (0x06) 17:25:32.747 DRIVER « [RES] [SendData] was sent: true 17:25:32.763 SERIAL « 0x01070013d20000023b (9 bytes) 17:25:32.763 SERIAL » [ACK] (0x06) 17:25:32.764 DRIVER « [REQ] [SendData] callback id: 210 transmit status: OK 17:25:32.773 SERIAL « 0x010b000400210570062d010a84 (13 bytes) 17:25:32.778 CNTRLR [Node 033] [~] [Configuration] 45: 10 => 10 17:25:32.779 SERIAL » [ACK] (0x06) 17:25:32.780 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 45 value size: 1 value: 10 17:25:32.788 SERIAL » 0x010a0013220370053225d376 (12 bytes) 17:25:32.789 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 211 └─[ConfigurationCCGet] parameter #: 50 17:25:32.789 CNTRLR « [Node 033] parameter #45 has value: 10 17:25:32.789 CNTRLR » [Node 033] querying parameter #71 value... 17:25:32.794 SERIAL « [ACK] (0x06) 17:25:32.797 SERIAL « 0x0104011301e8 (6 bytes) 17:25:32.798 SERIAL » [ACK] (0x06) 17:25:32.798 DRIVER « [RES] [SendData] was sent: true 17:25:32.817 SERIAL « 0x01070013d30000023a (9 bytes) 17:25:32.818 SERIAL » [ACK] (0x06) 17:25:32.818 DRIVER « [REQ] [SendData] callback id: 211 transmit status: OK 17:25:32.832 SERIAL « 0x010b0004002205700632011486 (13 bytes) 17:25:32.837 CNTRLR [Node 034] [~] [Configuration] 50: 20 => 20 17:25:32.838 SERIAL » [ACK] (0x06) 17:25:32.838 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 20 17:25:32.841 SERIAL » 0x010a0013210370054725d407 (12 bytes) 17:25:32.841 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 212 └─[ConfigurationCCGet] parameter #: 71 17:25:32.842 CNTRLR « [Node 034] parameter #50 has value: 20 17:25:32.842 CNTRLR » [Node 034] querying parameter #51 value... 17:25:32.845 SERIAL « [ACK] (0x06) 17:25:32.849 SERIAL « 0x0104011301e8 (6 bytes) 17:25:32.850 SERIAL » [ACK] (0x06) 17:25:32.852 DRIVER « [RES] [SendData] was sent: true 17:25:32.867 SERIAL « 0x01070013d40000023d (9 bytes) 17:25:32.867 SERIAL » [ACK] (0x06) 17:25:32.868 DRIVER « [REQ] [SendData] callback id: 212 transmit status: OK 17:25:32.877 SERIAL « 0x010b00040021057006470101e5 (13 bytes) 17:25:32.882 CNTRLR [Node 033] [~] [Configuration] 71: 1 => 1 17:25:32.884 SERIAL » [ACK] (0x06) 17:25:32.885 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 71 value size: 1 value: 1 17:25:32.887 SERIAL » 0x010a0013220370053325d571 (12 bytes) 17:25:32.888 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 213 └─[ConfigurationCCGet] parameter #: 51 17:25:32.888 CNTRLR « [Node 033] parameter #71 has value: 1 17:25:32.888 CNTRLR » [Node 033] querying parameter #72 value... 17:25:32.895 SERIAL « [ACK] (0x06) 17:25:32.897 SERIAL « 0x0104011301e8 (6 bytes) 17:25:32.897 SERIAL » [ACK] (0x06) 17:25:32.898 DRIVER « [RES] [SendData] was sent: true 17:25:32.916 SERIAL « 0x01070013d50000023c (9 bytes) 17:25:32.917 SERIAL » [ACK] (0x06) 17:25:32.917 DRIVER « [REQ] [SendData] callback id: 213 transmit status: OK 17:25:32.929 SERIAL « 0x010b0004002205700633010a99 (13 bytes) 17:25:32.935 CNTRLR [Node 034] [~] [Configuration] 51: 10 => 10 17:25:32.935 SERIAL » [ACK] (0x06) 17:25:32.936 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 51 value size: 1 value: 10 17:25:32.939 SERIAL » 0x010a0013210370054825d60a (12 bytes) 17:25:32.939 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 214 └─[ConfigurationCCGet] parameter #: 72 17:25:32.940 CNTRLR « [Node 034] parameter #51 has value: 10 17:25:32.940 CNTRLR » [Node 034] querying parameter #53 value... 17:25:32.943 SERIAL « [ACK] (0x06) 17:25:32.947 SERIAL « 0x0104011301e8 (6 bytes) 17:25:32.948 SERIAL » [ACK] (0x06) 17:25:32.949 DRIVER « [RES] [SendData] was sent: true 17:25:32.965 SERIAL « 0x01070013d60000023f (9 bytes) 17:25:32.965 SERIAL » [ACK] (0x06) 17:25:32.966 DRIVER « [REQ] [SendData] callback id: 214 transmit status: OK 17:25:32.975 SERIAL « 0x010b00040021057006480101ea (13 bytes) 17:25:32.980 CNTRLR [Node 033] [~] [Configuration] 72: 1 => 1 17:25:32.981 SERIAL » [ACK] (0x06) 17:25:32.981 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 72 value size: 1 value: 1 17:25:32.984 SERIAL » 0x010a0013220370053525d775 (12 bytes) 17:25:32.985 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 215 └─[ConfigurationCCGet] parameter #: 53 17:25:32.985 CNTRLR « [Node 033] parameter #72 has value: 1 17:25:32.985 CNTRLR » [Node 033] querying parameter #73 value... 17:25:32.988 SERIAL « [ACK] (0x06) 17:25:32.992 SERIAL « 0x0104011301e8 (6 bytes) 17:25:32.993 SERIAL » [ACK] (0x06) 17:25:32.994 DRIVER « [RES] [SendData] was sent: true 17:25:33.013 SERIAL « 0x01070013d70000033f (9 bytes) 17:25:33.013 SERIAL » [ACK] (0x06) 17:25:33.014 DRIVER « [REQ] [SendData] callback id: 215 transmit status: OK 17:25:33.028 SERIAL « 0x010c0004002206700635020064f6 (14 bytes) 17:25:33.033 CNTRLR [Node 034] [~] [Configuration] 53: 100 => 100 17:25:33.034 SERIAL » [ACK] (0x06) 17:25:33.034 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 53 value size: 2 value: 100 17:25:33.037 SERIAL » 0x010a0013210370054925d805 (12 bytes) 17:25:33.038 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 216 └─[ConfigurationCCGet] parameter #: 73 17:25:33.038 CNTRLR « [Node 034] parameter #53 has value: 100 17:25:33.038 CNTRLR » [Node 034] querying parameter #54 value... 17:25:33.041 SERIAL « [ACK] (0x06) 17:25:33.045 SERIAL « 0x0104011301e8 (6 bytes) 17:25:33.046 SERIAL » [ACK] (0x06) 17:25:33.047 DRIVER « [RES] [SendData] was sent: true 17:25:33.063 SERIAL « 0x01070013d800000231 (9 bytes) 17:25:33.063 SERIAL » [ACK] (0x06) 17:25:33.064 DRIVER « [REQ] [SendData] callback id: 216 transmit status: OK 17:25:33.074 SERIAL « 0x010b00040021057006490100ea (13 bytes) 17:25:33.079 CNTRLR [Node 033] [~] [Configuration] 73: 0 => 0 17:25:33.080 SERIAL » [ACK] (0x06) 17:25:33.080 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 73 value size: 1 value: 0 17:25:33.083 SERIAL » 0x010a0013220370053625d978 (12 bytes) 17:25:33.084 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 217 └─[ConfigurationCCGet] parameter #: 54 17:25:33.084 CNTRLR « [Node 033] parameter #73 has value: 0 17:25:33.084 CNTRLR [Node 033] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:25:33.084 CNTRLR [Node 033] Interview stage completed: CommandClasses 17:25:33.084 CNTRLR [Node 033] Interview stage completed: OverwriteConfig 17:25:33.085 CNTRLR » [Node 033] requesting node neighbors... 17:25:33.087 SERIAL « [ACK] (0x06) 17:25:33.091 SERIAL « 0x0104011301e8 (6 bytes) 17:25:33.092 SERIAL » [ACK] (0x06) 17:25:33.093 DRIVER « [RES] [SendData] was sent: true 17:25:33.112 SERIAL « 0x01070013d900000331 (9 bytes) 17:25:33.112 SERIAL » [ACK] (0x06) 17:25:33.113 DRIVER « [REQ] [SendData] callback id: 217 transmit status: OK 17:25:33.127 SERIAL « 0x010b0004002205700636011482 (13 bytes) 17:25:33.132 CNTRLR [Node 034] [~] [Configuration] 54: 20 => 20 17:25:33.133 SERIAL » [ACK] (0x06) 17:25:33.133 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 54 value size: 1 value: 20 17:25:33.136 SERIAL » 0x010700802100000059 (9 bytes) 17:25:33.136 DRIVER » [Node 033] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:25:33.137 CNTRLR « [Node 034] parameter #54 has value: 20 17:25:33.137 CNTRLR » [Node 034] querying parameter #55 value... 17:25:33.140 SERIAL « [ACK] (0x06) 17:25:33.141 SERIAL « 0x0120018065f9ee4b0600000000000000000000000000000000000000000000000 (34 bytes) 061 17:25:33.142 SERIAL » [ACK] (0x06) 17:25:33.142 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 9, 12, 13, 14, 15, 16, 18, 19, 20, 22, 23, 24, 25, 26, 28, 31, 34, 35 17:25:33.147 SERIAL » 0x010a0013220370053725da7a (12 bytes) 17:25:33.148 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 218 └─[ConfigurationCCGet] parameter #: 55 17:25:33.148 CNTRLR « [Node 033] node neighbors received: 1, 3, 6, 7, 9, 12, 13, 14, 15, 16, 18, 1 9, 20, 22, 23, 24, 25, 26, 28, 31, 34, 35 17:25:33.148 CNTRLR [Node 033] Interview stage completed: Neighbors 17:25:33.148 CNTRLR [Node 033] Interview completed 17:25:33.151 SERIAL « [ACK] (0x06) 17:25:33.156 SERIAL « 0x0104011301e8 (6 bytes) 17:25:33.156 SERIAL » [ACK] (0x06) 17:25:33.156 DRIVER « [RES] [SendData] was sent: true 17:25:33.176 SERIAL « 0x01070013da00000233 (9 bytes) 17:25:33.177 SERIAL » [ACK] (0x06) 17:25:33.177 DRIVER « [REQ] [SendData] callback id: 218 transmit status: OK 17:25:33.191 SERIAL « 0x010b0004002205700637010a9d (13 bytes) 17:25:33.196 CNTRLR [Node 034] [~] [Configuration] 55: 10 => 10 17:25:33.196 SERIAL » [ACK] (0x06) 17:25:33.197 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 55 value size: 1 value: 10 17:25:33.198 CNTRLR « [Node 034] parameter #55 has value: 10 17:25:33.198 CNTRLR » [Node 034] querying parameter #57 value... 17:25:33.202 SERIAL » 0x010a0013220370053925db75 (12 bytes) 17:25:33.202 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 219 └─[ConfigurationCCGet] parameter #: 57 17:25:33.204 SERIAL « [ACK] (0x06) 17:25:33.210 SERIAL « 0x0104011301e8 (6 bytes) 17:25:33.211 SERIAL » [ACK] (0x06) 17:25:33.211 DRIVER « [RES] [SendData] was sent: true 17:25:33.231 SERIAL « 0x01070013db00000333 (9 bytes) 17:25:33.231 SERIAL » [ACK] (0x06) 17:25:33.232 DRIVER « [REQ] [SendData] callback id: 219 transmit status: OK 17:25:33.246 SERIAL « 0x010c0004002206700639020064fa (14 bytes) 17:25:33.251 CNTRLR [Node 034] [~] [Configuration] 57: 100 => 100 17:25:33.252 SERIAL » [ACK] (0x06) 17:25:33.253 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 57 value size: 2 value: 100 17:25:33.254 CNTRLR « [Node 034] parameter #57 has value: 100 17:25:33.254 CNTRLR » [Node 034] querying parameter #58 value... 17:25:33.258 SERIAL » 0x010a0013220370053a25dc71 (12 bytes) 17:25:33.258 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 220 └─[ConfigurationCCGet] parameter #: 58 17:25:33.260 SERIAL « [ACK] (0x06) 17:25:33.266 SERIAL « 0x0104011301e8 (6 bytes) 17:25:33.267 SERIAL » [ACK] (0x06) 17:25:33.267 DRIVER « [RES] [SendData] was sent: true 17:25:33.287 SERIAL « 0x01070013dc00000235 (9 bytes) 17:25:33.287 SERIAL » [ACK] (0x06) 17:25:33.288 DRIVER « [REQ] [SendData] callback id: 220 transmit status: OK 17:25:33.301 SERIAL « 0x010c000400220670063a020e1083 (14 bytes) 17:25:33.308 CNTRLR [Node 034] [~] [Configuration] 58: 3600 => 3600 17:25:33.309 SERIAL » [ACK] (0x06) 17:25:33.313 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 58 value size: 2 value: 3600 17:25:33.314 CNTRLR « [Node 034] parameter #58 has value: 3600 17:25:33.315 CNTRLR » [Node 034] querying parameter #59 value... 17:25:33.320 SERIAL » 0x010a0013220370053b25dd71 (12 bytes) 17:25:33.320 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 221 └─[ConfigurationCCGet] parameter #: 59 17:25:33.323 SERIAL « [ACK] (0x06) 17:25:33.329 SERIAL « 0x0104011301e8 (6 bytes) 17:25:33.329 SERIAL » [ACK] (0x06) 17:25:33.330 DRIVER « [RES] [SendData] was sent: true 17:25:33.349 SERIAL « 0x01070013dd00000335 (9 bytes) 17:25:33.350 SERIAL » [ACK] (0x06) 17:25:33.350 DRIVER « [REQ] [SendData] callback id: 221 transmit status: OK 17:25:33.364 SERIAL « 0x010c000400220670063b020e1082 (14 bytes) 17:25:33.371 CNTRLR [Node 034] [~] [Configuration] 59: 3600 => 3600 17:25:33.372 SERIAL » [ACK] (0x06) 17:25:33.373 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 59 value size: 2 value: 3600 17:25:33.374 CNTRLR « [Node 034] parameter #59 has value: 3600 17:25:33.374 CNTRLR » [Node 034] querying parameter #60 value... 17:25:33.378 SERIAL » 0x010a0013220370053c25de75 (12 bytes) 17:25:33.378 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 222 └─[ConfigurationCCGet] parameter #: 60 17:25:33.380 SERIAL « [ACK] (0x06) 17:25:33.386 SERIAL « 0x0104011301e8 (6 bytes) 17:25:33.387 SERIAL » [ACK] (0x06) 17:25:33.388 DRIVER « [RES] [SendData] was sent: true 17:25:33.407 SERIAL « 0x01070013de00000237 (9 bytes) 17:25:33.407 SERIAL » [ACK] (0x06) 17:25:33.407 DRIVER « [REQ] [SendData] callback id: 222 transmit status: OK 17:25:33.421 SERIAL « 0x010b000400220570063c01009c (13 bytes) 17:25:33.426 CNTRLR [Node 034] [~] [Configuration] 60: 0 => 0 17:25:33.427 SERIAL » [ACK] (0x06) 17:25:33.428 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 1 value: 0 17:25:33.429 CNTRLR « [Node 034] parameter #60 has value: 0 17:25:33.430 CNTRLR [Node 034] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:25:33.431 CNTRLR [Node 034] ProtectionCC: doing a partial interview... 17:25:33.431 CNTRLR » [Node 034] querying protection status... 17:25:33.436 SERIAL » 0x010900132202750225df48 (11 bytes) 17:25:33.436 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 223 └─[ProtectionCCGet] 17:25:33.445 SERIAL « [ACK] (0x06) 17:25:33.446 SERIAL « 0x0104011301e8 (6 bytes) 17:25:33.446 SERIAL » [ACK] (0x06) 17:25:33.447 DRIVER « [RES] [SendData] was sent: true 17:25:33.464 SERIAL « 0x01070013df00000236 (9 bytes) 17:25:33.465 SERIAL » [ACK] (0x06) 17:25:33.465 DRIVER « [REQ] [SendData] callback id: 223 transmit status: OK 17:25:33.478 SERIAL « 0x010a000400220475030000a1 (12 bytes) 17:25:33.479 CNTRLR [Node 034] [~] [Protection] local: 0 => 0 [Endpoint 0] 17:25:33.480 CNTRLR [Node 034] [~] [Protection] rf: 0 => 0 [Endpoint 0] 17:25:33.480 SERIAL » [ACK] (0x06) 17:25:33.482 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 17:25:33.483 CNTRLR « [Node 034] received protection status: local: Unprotected rf Unprotected 17:25:33.483 CNTRLR [Node 034] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 17:25:33.514 CNTRLR [Node 034] AssociationCC: doing a partial interview... 17:25:33.514 CNTRLR [Node 034] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:25:33.514 CNTRLR [Node 034] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:25:33.515 CNTRLR [Node 034] MultiChannelAssociationCC: doing a partial interview... 17:25:33.515 CNTRLR » [Node 034] querying multi channel association group #1... 17:25:33.518 SERIAL » 0x010a001322038e020125e08f (12 bytes) 17:25:33.519 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 224 └─[MultiChannelAssociationCCGet] group id: 1 17:25:33.520 SERIAL « [ACK] (0x06) 17:25:33.527 SERIAL « 0x0104011301e8 (6 bytes) 17:25:33.527 SERIAL » [ACK] (0x06) 17:25:33.528 DRIVER « [RES] [SendData] was sent: true 17:25:33.547 SERIAL « 0x01070013e000000209 (9 bytes) 17:25:33.548 SERIAL » [ACK] (0x06) 17:25:33.548 DRIVER « [REQ] [SendData] callback id: 224 transmit status: OK 17:25:33.563 SERIAL « 0x010e00040022088e0301010000010053 (16 bytes) 17:25:33.563 SERIAL » [ACK] (0x06) 17:25:33.564 CNTRLR [Node 034] [~] [Multi Channel Association] maxNodes[1]: 1 => 1 17:25:33.565 CNTRLR [Node 034] [~] [Multi Channel Association] nodeIds[1]: => 17:25:33.567 CNTRLR [Node 034] [~] [Multi Channel Association] endpoints[1]: [object Object] => [o bject Object] 17:25:33.568 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 1 node ids: endpoints: 1:0 17:25:33.569 CNTRLR « [Node 034] received information for multi channel association group #1: maximum # of nodes: 1 currently assigned nodes: currently assigned endpoints: 1:0 17:25:33.569 CNTRLR » [Node 034] querying multi channel association group #2... 17:25:33.573 SERIAL » 0x010a001322038e020225e18d (12 bytes) 17:25:33.573 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 225 └─[MultiChannelAssociationCCGet] group id: 2 17:25:33.581 SERIAL « [ACK] (0x06) 17:25:33.584 SERIAL « 0x0104011301e8 (6 bytes) 17:25:33.585 SERIAL » [ACK] (0x06) 17:25:33.586 DRIVER « [RES] [SendData] was sent: true 17:25:33.603 SERIAL « 0x01070013e100000309 (9 bytes) 17:25:33.603 SERIAL » [ACK] (0x06) 17:25:33.603 DRIVER « [REQ] [SendData] callback id: 225 transmit status: OK 17:25:33.617 SERIAL « 0x010b00040022058e030205005d (13 bytes) 17:25:33.617 SERIAL » [ACK] (0x06) 17:25:33.618 CNTRLR [Node 034] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 17:25:33.619 CNTRLR [Node 034] [~] [Multi Channel Association] nodeIds[2]: => 17:25:33.619 CNTRLR [Node 034] [~] [Multi Channel Association] endpoints[2]: => 17:25:33.620 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 17:25:33.621 CNTRLR « [Node 034] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 17:25:33.621 CNTRLR » [Node 034] querying multi channel association group #3... 17:25:33.625 SERIAL » 0x010a001322038e020325e28f (12 bytes) 17:25:33.625 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 226 └─[MultiChannelAssociationCCGet] group id: 3 17:25:33.627 SERIAL « [ACK] (0x06) 17:25:33.633 SERIAL « 0x0104011301e8 (6 bytes) 17:25:33.634 SERIAL » [ACK] (0x06) 17:25:33.635 DRIVER « [RES] [SendData] was sent: true 17:25:33.654 SERIAL « 0x01070013e20000030a (9 bytes) 17:25:33.654 SERIAL » [ACK] (0x06) 17:25:33.655 DRIVER « [REQ] [SendData] callback id: 226 transmit status: OK 17:25:33.699 SERIAL « 0x010b00040022058e030305005c (13 bytes) 17:25:33.700 SERIAL » [ACK] (0x06) 17:25:33.702 CNTRLR [Node 034] [~] [Multi Channel Association] maxNodes[3]: 5 => 5 17:25:33.703 CNTRLR [Node 034] [~] [Multi Channel Association] nodeIds[3]: => 17:25:33.704 CNTRLR [Node 034] [~] [Multi Channel Association] endpoints[3]: => 17:25:33.705 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 3 maximum # of nodes: 5 node ids: endpoints: 17:25:33.706 CNTRLR « [Node 034] received information for multi channel association group #3: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 17:25:33.706 CNTRLR » [Node 034] querying multi channel association group #4... 17:25:33.709 SERIAL » 0x010a001322038e020425e389 (12 bytes) 17:25:33.710 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 227 └─[MultiChannelAssociationCCGet] group id: 4 17:25:33.712 SERIAL « [ACK] (0x06) 17:25:33.718 SERIAL « 0x0104011301e8 (6 bytes) 17:25:33.719 SERIAL » [ACK] (0x06) 17:25:33.720 DRIVER « [RES] [SendData] was sent: true 17:25:33.742 SERIAL « 0x01070013e30000030b (9 bytes) 17:25:33.742 SERIAL » [ACK] (0x06) 17:25:33.743 DRIVER « [REQ] [SendData] callback id: 227 transmit status: OK 17:25:33.757 SERIAL « 0x010b00040022058e030405005b (13 bytes) 17:25:33.757 SERIAL » [ACK] (0x06) 17:25:33.758 CNTRLR [Node 034] [~] [Multi Channel Association] maxNodes[4]: 5 => 5 17:25:33.759 CNTRLR [Node 034] [~] [Multi Channel Association] nodeIds[4]: => 17:25:33.760 CNTRLR [Node 034] [~] [Multi Channel Association] endpoints[4]: => 17:25:33.761 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 4 maximum # of nodes: 5 node ids: endpoints: 17:25:33.762 CNTRLR « [Node 034] received information for multi channel association group #4: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 17:25:33.762 CNTRLR » [Node 034] querying multi channel association group #5... 17:25:33.766 SERIAL » 0x010a001322038e020525e48f (12 bytes) 17:25:33.766 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 228 └─[MultiChannelAssociationCCGet] group id: 5 17:25:33.768 SERIAL « [ACK] (0x06) 17:25:33.774 SERIAL « 0x0104011301e8 (6 bytes) 17:25:33.775 SERIAL » [ACK] (0x06) 17:25:33.776 DRIVER « [RES] [SendData] was sent: true 17:25:33.795 SERIAL « 0x01070013e40000020d (9 bytes) 17:25:33.795 SERIAL » [ACK] (0x06) 17:25:33.795 DRIVER « [REQ] [SendData] callback id: 228 transmit status: OK 17:25:33.809 SERIAL « 0x010b00040022058e030505005a (13 bytes) 17:25:33.809 SERIAL » [ACK] (0x06) 17:25:33.810 CNTRLR [Node 034] [~] [Multi Channel Association] maxNodes[5]: 5 => 5 17:25:33.811 CNTRLR [Node 034] [~] [Multi Channel Association] nodeIds[5]: => 17:25:33.811 CNTRLR [Node 034] [~] [Multi Channel Association] endpoints[5]: => 17:25:33.812 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 5 maximum # of nodes: 5 node ids: endpoints: 17:25:33.813 CNTRLR « [Node 034] received information for multi channel association group #5: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 17:25:33.813 CNTRLR [Node 034] [~] [Association] hasLifeline: true => true [internal] 17:25:33.813 CNTRLR [Node 034] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:25:33.814 CNTRLR [Node 034] AssociationGroupInfoCC: doing a partial interview... 17:25:33.814 CNTRLR [Node 034] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 17:25:33.815 CNTRLR [Node 034] CentralSceneCC: doing a partial interview... 17:25:33.815 CNTRLR [Node 034] [~] [Central Scene] interviewComplete: true [Endpoint 0] [internal] => true 17:25:33.815 CNTRLR [Node 034] NotificationCC: doing a partial interview... 17:25:33.816 CNTRLR [Node 034] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 17:25:33.816 CNTRLR [Node 034] Interview stage completed: CommandClasses 17:25:33.816 CNTRLR [Node 034] Interview stage completed: OverwriteConfig 17:25:33.816 CNTRLR » [Node 034] requesting node neighbors... 17:25:33.819 SERIAL » 0x01070080220000005a (9 bytes) 17:25:33.820 DRIVER » [Node 034] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:25:33.822 SERIAL « [ACK] (0x06) 17:25:33.827 SERIAL « 0x0120018065f9ac5b0500000000000000000000000000000000000000000000000 (34 bytes) 030 17:25:33.827 SERIAL » [ACK] (0x06) 17:25:33.830 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 9, 12, 13, 14, 15, 16, 19, 20, 22, 24, 25, 26, 28, 29, 31, 33, 35 17:25:33.833 CNTRLR « [Node 034] node neighbors received: 1, 3, 6, 7, 9, 12, 13, 14, 15, 16, 19, 2 0, 22, 24, 25, 26, 28, 29, 31, 33, 35 17:25:33.833 CNTRLR [Node 034] Interview stage completed: Neighbors 17:25:33.833 CNTRLR [Node 034] Interview completed 17:25:34.079 SERIAL « 0x01090004000803200100d8 (11 bytes) 17:25:34.079 SERIAL » [ACK] (0x06) 17:25:34.080 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:25:34.082 CNTRLR [Node 008] treating BasicCC Set as a report 17:25:34.082 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:25:44.884 SERIAL « 0x010c000400030631050422048763 (14 bytes) 17:25:44.887 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:25:44.888 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 222.8 => 115.9 [Endpoint 0] 17:25:44.889 SERIAL » [ACK] (0x06) 17:25:44.893 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 115.9 17:25:46.499 SERIAL « 0x010900040008033003ff35 (11 bytes) 17:25:46.501 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:25:46.502 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:25:46.502 SERIAL » [ACK] (0x06) 17:25:46.504 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:25:46.554 SERIAL « 0x010900040008032001ff27 (11 bytes) 17:25:46.554 SERIAL » [ACK] (0x06) 17:25:46.555 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:25:46.557 CNTRLR [Node 008] treating BasicCC Set as a report 17:25:46.557 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:25:47.009 SERIAL « 0x01080004001e0284076c (10 bytes) 17:25:47.010 SERIAL » [ACK] (0x06) 17:25:47.011 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:25:47.013 CNTRLR « [Node 030] received wakeup notification 17:25:47.014 CNTRLR [Node 030] The node is now awake. 17:25:47.021 SERIAL » 0x010900131e02800225e5bb (11 bytes) 17:25:47.022 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 229 └─[BatteryCCGet] 17:25:47.025 SERIAL « [ACK] (0x06) 17:25:47.034 SERIAL « 0x0104011301e8 (6 bytes) 17:25:47.035 SERIAL » [ACK] (0x06) 17:25:47.036 DRIVER « [RES] [SendData] was sent: true 17:25:47.053 SERIAL « 0x01070013e50000030d (9 bytes) 17:25:47.053 SERIAL » [ACK] (0x06) 17:25:47.054 DRIVER « [REQ] [SendData] callback id: 229 transmit status: OK 17:25:47.071 SERIAL « 0x01090004001e0380035539 (11 bytes) 17:25:47.072 CNTRLR [Node 030] [~] [Battery] level: 85 => 85 [Endpoint 0] 17:25:47.074 CNTRLR [Node 030] [~] [Battery] isLow: false => false [Endpoint 0] 17:25:47.074 SERIAL » [ACK] (0x06) 17:25:47.077 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 85 is low: false 17:25:47.080 CNTRLR « [Node 030] received response for battery information: level: 85 17:25:47.080 CNTRLR [Node 030] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:25:47.143 CNTRLR [Node 030] WakeUpCC: doing a partial interview... 17:25:47.144 CNTRLR » [Node 030] retrieving wakeup interval from the device... 17:25:47.151 SERIAL » 0x010900131e02840525e6bb (11 bytes) 17:25:47.151 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 230 └─[WakeUpCCIntervalGet] 17:25:47.153 SERIAL « [ACK] (0x06) 17:25:47.159 SERIAL « 0x0104011301e8 (6 bytes) 17:25:47.160 SERIAL » [ACK] (0x06) 17:25:47.160 DRIVER « [RES] [SendData] was sent: true 17:25:47.176 SERIAL « 0x01070013e60000020f (9 bytes) 17:25:47.177 SERIAL » [ACK] (0x06) 17:25:47.177 DRIVER « [REQ] [SendData] callback id: 230 transmit status: OK 17:25:47.187 SERIAL « 0x010c0004001e06840600038401eb (14 bytes) 17:25:47.188 CNTRLR [Node 030] [~] [Wake Up] wakeUpInterval: 900 => 900 [Endpoint 0] 17:25:47.189 CNTRLR [Node 030] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 17:25:47.189 SERIAL » [ACK] (0x06) 17:25:47.190 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 900 seconds controller node id: 1 17:25:47.192 CNTRLR « [Node 030] received wakeup configuration: wakeup interval: 900 seconds controller node: 1 17:25:47.192 CNTRLR [Node 030] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:25:47.192 CNTRLR [Node 030] AssociationCC: doing a partial interview... 17:25:47.193 CNTRLR [Node 030] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:25:47.193 CNTRLR [Node 030] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:25:47.194 CNTRLR [Node 030] BasicCC: doing a partial interview... 17:25:47.194 CNTRLR » [Node 030] querying Basic CC state... 17:25:47.198 SERIAL » 0x010900131e02200225e719 (11 bytes) 17:25:47.198 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 231 └─[BasicCCGet] 17:25:47.200 SERIAL « [ACK] (0x06) 17:25:47.206 SERIAL « 0x0104011301e8 (6 bytes) 17:25:47.206 SERIAL » [ACK] (0x06) 17:25:47.207 DRIVER « [RES] [SendData] was sent: true 17:25:47.223 SERIAL « 0x01070013e70000020e (9 bytes) 17:25:47.223 SERIAL » [ACK] (0x06) 17:25:47.224 DRIVER « [REQ] [SendData] callback id: 231 transmit status: OK 17:25:47.233 SERIAL « 0x01090004001e03200300cc (11 bytes) 17:25:47.234 SERIAL » [ACK] (0x06) 17:25:47.235 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCReport] current value: 0 17:25:47.237 CNTRLR « [Node 030] received Basic CC state: current value: 0 17:25:47.237 CNTRLR [Node 030] [~] [Basic] interviewComplete: true => true [Endpoint 0] [internal] 17:25:47.237 CNTRLR [Node 030] BinarySensorCC: doing a partial interview... 17:25:47.238 CNTRLR » [Node 030] querying current value... 17:25:47.242 SERIAL » 0x010900131e02300225e806 (11 bytes) 17:25:47.243 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 232 └─[BinarySensorCCGet] type: Any 17:25:47.244 SERIAL « [ACK] (0x06) 17:25:47.251 SERIAL « 0x0104011301e8 (6 bytes) 17:25:47.252 SERIAL » [ACK] (0x06) 17:25:47.252 DRIVER « [RES] [SendData] was sent: true 17:25:47.268 SERIAL « 0x01070013e800000201 (9 bytes) 17:25:47.268 SERIAL » [ACK] (0x06) 17:25:47.268 DRIVER « [REQ] [SendData] callback id: 232 transmit status: OK 17:25:47.278 SERIAL « 0x01090004001e03300300dc (11 bytes) 17:25:47.278 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:25:47.279 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:25:47.279 SERIAL » [ACK] (0x06) 17:25:47.280 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:25:47.282 CNTRLR « [Node 030] received current value: false 17:25:47.282 CNTRLR [Node 030] [~] [Binary Sensor] interviewComplete: true [Endpoint 0] [internal] => true 17:25:47.283 CNTRLR [Node 030] MultilevelSensorCC: doing a partial interview... 17:25:47.283 CNTRLR » [Node 030] querying Air temperature sensor reading... 17:25:47.287 SERIAL » 0x010b00131e043104010025e905 (13 bytes) 17:25:47.287 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 233 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 17:25:47.289 SERIAL « [ACK] (0x06) 17:25:47.295 SERIAL « 0x0104011301e8 (6 bytes) 17:25:47.296 SERIAL » [ACK] (0x06) 17:25:47.296 DRIVER « [RES] [SendData] was sent: true 17:25:47.313 SERIAL « 0x01070013e900000200 (9 bytes) 17:25:47.313 SERIAL » [ACK] (0x06) 17:25:47.314 DRIVER « [REQ] [SendData] callback id: 233 transmit status: OK 17:25:47.324 SERIAL « 0x010c0004001e063105012200c73f (14 bytes) 17:25:47.325 CNTRLR [Node 030] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 17:25:47.325 CNTRLR [Node 030] [~] [Multilevel Sensor] Air temperature: 20 => 19.9 [Endpoint 0] 17:25:47.326 SERIAL » [ACK] (0x06) 17:25:47.327 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 19.9 17:25:47.330 CNTRLR « [Node 030] received current Air temperature sensor reading: 19.9 °C 17:25:47.331 CNTRLR » [Node 030] querying Illuminance sensor reading... 17:25:47.335 SERIAL » 0x010b00131e043104030825ea0c (13 bytes) 17:25:47.335 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 234 └─[MultilevelSensorCCGet] sensor type: Illuminance scale: Lux 17:25:47.339 SERIAL « [ACK] (0x06) 17:25:47.376 SERIAL « 0x0104011301e8 (6 bytes) 17:25:47.377 SERIAL » [ACK] (0x06) 17:25:47.377 DRIVER « [RES] [SendData] was sent: true 17:25:47.380 SERIAL « 0x01070013ea00000302 (9 bytes) 17:25:47.380 SERIAL » [ACK] (0x06) 17:25:47.381 DRIVER « [REQ] [SendData] callback id: 234 transmit status: OK 17:25:47.383 SERIAL « 0x010c0004001e063105030a0002d0 (14 bytes) 17:25:47.384 CNTRLR [Node 030] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 17:25:47.384 CNTRLR [Node 030] [~] [Multilevel Sensor] Illuminance: 84 => 2 [Endpoint 0] 17:25:47.385 SERIAL » [ACK] (0x06) 17:25:47.386 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 2 17:25:47.387 CNTRLR « [Node 030] received current Illuminance sensor reading: 2 Lux 17:25:47.388 CNTRLR [Node 030] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 17:25:47.388 CNTRLR [Node 030] ConfigurationCC: Loading configuration parameters from device confi g 17:25:47.394 CNTRLR [Node 030] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:25:47.395 CNTRLR [Node 030] [Configuration] 1: metadata updated 17:25:47.396 CNTRLR [Node 030] [Configuration] 2: metadata updated 17:25:47.398 CNTRLR [Node 030] [Configuration] 3: metadata updated 17:25:47.400 CNTRLR [Node 030] [Configuration] 4: metadata updated 17:25:47.401 CNTRLR [Node 030] [Configuration] 6: metadata updated 17:25:47.402 CNTRLR [Node 030] [Configuration] 8: metadata updated 17:25:47.403 CNTRLR [Node 030] [Configuration] 9: metadata updated 17:25:47.404 CNTRLR [Node 030] [Configuration] 12: metadata updated 17:25:47.405 CNTRLR [Node 030] [Configuration] 14: metadata updated 17:25:47.406 CNTRLR [Node 030] [Configuration] 16: metadata updated 17:25:47.407 CNTRLR [Node 030] [Configuration] 20: metadata updated 17:25:47.408 CNTRLR [Node 030] [Configuration] 22: metadata updated 17:25:47.409 CNTRLR [Node 030] [Configuration] 24: metadata updated 17:25:47.411 CNTRLR [Node 030] [Configuration] 26: metadata updated 17:25:47.412 CNTRLR [Node 030] [Configuration] 40: metadata updated 17:25:47.416 CNTRLR [Node 030] [Configuration] 42: metadata updated 17:25:47.417 CNTRLR [Node 030] [Configuration] 60: metadata updated 17:25:47.417 CNTRLR [Node 030] [Configuration] 62: metadata updated 17:25:47.418 CNTRLR [Node 030] [Configuration] 64: metadata updated 17:25:47.419 CNTRLR [Node 030] [Configuration] 66: metadata updated 17:25:47.420 CNTRLR [Node 030] [Configuration] 80: metadata updated 17:25:47.421 CNTRLR [Node 030] [Configuration] 81: metadata updated 17:25:47.422 CNTRLR [Node 030] [Configuration] 82: metadata updated 17:25:47.423 CNTRLR [Node 030] [Configuration] 83: metadata updated 17:25:47.424 CNTRLR [Node 030] [Configuration] 86: metadata updated 17:25:47.425 CNTRLR [Node 030] [Configuration] 87: metadata updated 17:25:47.426 CNTRLR [Node 030] [Configuration] 89: metadata updated 17:25:47.427 CNTRLR [Node 030] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:25:47.427 CNTRLR » [Node 030] querying parameter #1 value... 17:25:47.431 SERIAL » 0x010a00131e0370050125eb41 (12 bytes) 17:25:47.431 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 235 └─[ConfigurationCCGet] parameter #: 1 17:25:47.439 SERIAL « [ACK] (0x06) 17:25:47.450 SERIAL « 0x0104011301e8 (6 bytes) 17:25:47.450 SERIAL » [ACK] (0x06) 17:25:47.467 DRIVER « [RES] [SendData] was sent: true 17:25:47.484 SERIAL « 0x01070013eb00000202 (9 bytes) 17:25:47.484 SERIAL » [ACK] (0x06) 17:25:47.488 DRIVER « [REQ] [SendData] callback id: 235 transmit status: OK 17:25:47.495 SERIAL « 0x010b0004001e05700601010a97 (13 bytes) 17:25:47.501 CNTRLR [Node 030] [~] [Configuration] 1: 10 => 10 17:25:47.502 SERIAL » [ACK] (0x06) 17:25:47.504 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 10 17:25:47.506 CNTRLR « [Node 030] parameter #1 has value: 10 17:25:47.506 CNTRLR » [Node 030] querying parameter #2 value... 17:25:47.511 SERIAL » 0x010a00131e0370050225ec45 (12 bytes) 17:25:47.511 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 236 └─[ConfigurationCCGet] parameter #: 2 17:25:47.521 SERIAL « [ACK] (0x06) 17:25:47.522 SERIAL « 0x0104011301e8 (6 bytes) 17:25:47.523 SERIAL » [ACK] (0x06) 17:25:47.524 DRIVER « [RES] [SendData] was sent: true 17:25:47.536 SERIAL « 0x01070013ec00000205 (9 bytes) 17:25:47.537 SERIAL » [ACK] (0x06) 17:25:47.537 DRIVER « [REQ] [SendData] callback id: 236 transmit status: OK 17:25:47.571 SERIAL « 0x010b0004001e05700602010f91 (13 bytes) 17:25:47.577 CNTRLR [Node 030] [~] [Configuration] 2: 15 => 15 17:25:47.577 SERIAL » [ACK] (0x06) 17:25:47.578 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 15 17:25:47.579 CNTRLR « [Node 030] parameter #2 has value: 15 17:25:47.580 CNTRLR » [Node 030] querying parameter #3 value... 17:25:47.583 SERIAL » 0x010a00131e0370050325ed45 (12 bytes) 17:25:47.583 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 237 └─[ConfigurationCCGet] parameter #: 3 17:25:47.587 SERIAL « [ACK] (0x06) 17:25:47.591 SERIAL « 0x0104011301e8 (6 bytes) 17:25:47.592 SERIAL » [ACK] (0x06) 17:25:47.592 DRIVER « [RES] [SendData] was sent: true 17:25:47.608 SERIAL « 0x01070013ed00000305 (9 bytes) 17:25:47.609 SERIAL » [ACK] (0x06) 17:25:47.609 DRIVER « [REQ] [SendData] callback id: 237 transmit status: OK 17:25:47.619 SERIAL « 0x010b0004001e0570060301019e (13 bytes) 17:25:47.624 CNTRLR [Node 030] [~] [Configuration] 3: 1 => 1 17:25:47.625 SERIAL » [ACK] (0x06) 17:25:47.626 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 1 17:25:47.627 CNTRLR « [Node 030] parameter #3 has value: 1 17:25:47.627 CNTRLR » [Node 030] querying parameter #4 value... 17:25:47.631 SERIAL » 0x010a00131e0370050425ee41 (12 bytes) 17:25:47.631 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 238 └─[ConfigurationCCGet] parameter #: 4 17:25:47.633 SERIAL « [ACK] (0x06) 17:25:47.646 SERIAL « 0x0104011301e8 (6 bytes) 17:25:47.646 SERIAL » [ACK] (0x06) 17:25:47.647 DRIVER « [RES] [SendData] was sent: true 17:25:47.656 SERIAL « 0x01070013ee00000207 (9 bytes) 17:25:47.657 SERIAL » [ACK] (0x06) 17:25:47.657 DRIVER « [REQ] [SendData] callback id: 238 transmit status: OK 17:25:47.667 SERIAL « 0x010b0004001e0570060401029a (13 bytes) 17:25:47.672 CNTRLR [Node 030] [~] [Configuration] 4: 2 => 2 17:25:47.673 SERIAL » [ACK] (0x06) 17:25:47.674 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 1 value: 2 17:25:47.676 CNTRLR « [Node 030] parameter #4 has value: 2 17:25:47.676 CNTRLR » [Node 030] querying parameter #6 value... 17:25:47.680 SERIAL » 0x010a00131e0370050625ef42 (12 bytes) 17:25:47.681 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 239 └─[ConfigurationCCGet] parameter #: 6 17:25:47.684 SERIAL « [ACK] (0x06) 17:25:47.689 SERIAL « 0x0104011301e8 (6 bytes) 17:25:47.689 SERIAL » [ACK] (0x06) 17:25:47.690 DRIVER « [RES] [SendData] was sent: true 17:25:47.706 SERIAL « 0x01070013ef00000206 (9 bytes) 17:25:47.706 SERIAL » [ACK] (0x06) 17:25:47.707 DRIVER « [REQ] [SendData] callback id: 239 transmit status: OK 17:25:47.717 SERIAL « 0x010c0004001e0670060602001e83 (14 bytes) 17:25:47.722 CNTRLR [Node 030] [~] [Configuration] 6: 30 => 30 17:25:47.723 SERIAL » [ACK] (0x06) 17:25:47.724 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 2 value: 30 17:25:47.725 CNTRLR « [Node 030] parameter #6 has value: 30 17:25:47.725 CNTRLR » [Node 030] querying parameter #8 value... 17:25:47.729 SERIAL » 0x010a00131e0370050825f053 (12 bytes) 17:25:47.729 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 240 └─[ConfigurationCCGet] parameter #: 8 17:25:47.735 SERIAL « [ACK] (0x06) 17:25:47.741 SERIAL « 0x0104011301e8 (6 bytes) 17:25:47.741 SERIAL » [ACK] (0x06) 17:25:47.742 DRIVER « [RES] [SendData] was sent: true 17:25:47.758 SERIAL « 0x01070013f000000318 (9 bytes) 17:25:47.759 SERIAL » [ACK] (0x06) 17:25:47.760 DRIVER « [REQ] [SendData] callback id: 240 transmit status: OK 17:25:47.769 SERIAL « 0x010b0004001e05700608010094 (13 bytes) 17:25:47.774 CNTRLR [Node 030] [~] [Configuration] 8: 0 => 0 17:25:47.775 SERIAL » [ACK] (0x06) 17:25:47.775 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 0 17:25:47.777 CNTRLR « [Node 030] parameter #8 has value: 0 17:25:47.777 CNTRLR » [Node 030] querying parameter #9 value... 17:25:47.781 SERIAL » 0x010a00131e0370050925f153 (12 bytes) 17:25:47.781 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 241 └─[ConfigurationCCGet] parameter #: 9 17:25:47.783 SERIAL « [ACK] (0x06) 17:25:47.789 SERIAL « 0x0104011301e8 (6 bytes) 17:25:47.789 SERIAL » [ACK] (0x06) 17:25:47.789 DRIVER « [RES] [SendData] was sent: true 17:25:47.806 SERIAL « 0x01070013f100000218 (9 bytes) 17:25:47.806 SERIAL » [ACK] (0x06) 17:25:47.807 DRIVER « [REQ] [SendData] callback id: 241 transmit status: OK 17:25:47.817 SERIAL « 0x010c0004001e06700609020028ba (14 bytes) 17:25:47.822 CNTRLR [Node 030] [~] [Configuration] 9: 40 => 40 17:25:47.823 SERIAL » [ACK] (0x06) 17:25:47.823 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 2 value: 40 17:25:47.825 CNTRLR « [Node 030] parameter #9 has value: 40 17:25:47.825 CNTRLR » [Node 030] querying parameter #12 value... 17:25:47.829 SERIAL » 0x010a00131e0370050c25f255 (12 bytes) 17:25:47.829 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 242 └─[ConfigurationCCGet] parameter #: 12 17:25:47.834 SERIAL « [ACK] (0x06) 17:25:47.839 SERIAL « 0x0104011301e8 (6 bytes) 17:25:47.842 SERIAL » [ACK] (0x06) 17:25:47.842 DRIVER « [RES] [SendData] was sent: true 17:25:47.854 SERIAL « 0x01070013f20000021b (9 bytes) 17:25:47.854 SERIAL » [ACK] (0x06) 17:25:47.855 DRIVER « [REQ] [SendData] callback id: 242 transmit status: OK 17:25:47.865 SERIAL « 0x010b0004001e0570060c010090 (13 bytes) 17:25:47.875 CNTRLR [Node 030] [~] [Configuration] 12: 0 => 0 17:25:47.875 SERIAL » [ACK] (0x06) 17:25:47.876 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 1 value: 0 17:25:47.877 CNTRLR « [Node 030] parameter #12 has value: 0 17:25:47.877 CNTRLR » [Node 030] querying parameter #14 value... 17:25:47.881 SERIAL » 0x010a00131e0370050e25f356 (12 bytes) 17:25:47.881 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 243 └─[ConfigurationCCGet] parameter #: 14 17:25:47.885 SERIAL « 0x010c00040003063105042209e50c (14 bytes) 17:25:47.887 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:25:47.887 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 115.9 => 253.3 [Endpoint 0] 17:25:47.888 SERIAL » [ACK] (0x06) 17:25:47.889 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 253.3 17:25:47.890 SERIAL « [CAN] (0x18) 17:25:47.892 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 17:25:47.992 SERIAL » 0x010a00131e0370050e25f356 (12 bytes) 17:25:47.993 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 243 └─[ConfigurationCCGet] parameter #: 14 17:25:47.995 SERIAL « [ACK] (0x06) 17:25:48.001 SERIAL « 0x0104011301e8 (6 bytes) 17:25:48.001 SERIAL » [ACK] (0x06) 17:25:48.002 DRIVER « [RES] [SendData] was sent: true 17:25:48.018 SERIAL « 0x01070013f30000021a (9 bytes) 17:25:48.019 SERIAL » [ACK] (0x06) 17:25:48.019 DRIVER « [REQ] [SendData] callback id: 243 transmit status: OK 17:25:48.029 SERIAL « 0x010b0004001e0570060e01ff6d (13 bytes) 17:25:48.036 CNTRLR [Node 030] [~] [Configuration] 14: 255 => 255 17:25:48.037 SERIAL » [ACK] (0x06) 17:25:48.038 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 255 17:25:48.040 CNTRLR « [Node 030] parameter #14 has value: 255 17:25:48.040 CNTRLR » [Node 030] querying parameter #16 value... 17:25:48.045 SERIAL » 0x010a00131e0370051025f44f (12 bytes) 17:25:48.046 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 244 └─[ConfigurationCCGet] parameter #: 16 17:25:48.049 SERIAL « [ACK] (0x06) 17:25:48.055 SERIAL « 0x0104011301e8 (6 bytes) 17:25:48.058 SERIAL » [ACK] (0x06) 17:25:48.059 DRIVER « [RES] [SendData] was sent: true 17:25:48.071 SERIAL « 0x01070013f40000021d (9 bytes) 17:25:48.072 SERIAL » [ACK] (0x06) 17:25:48.072 DRIVER « [REQ] [SendData] callback id: 244 transmit status: OK 17:25:48.082 SERIAL « 0x010b0004001e0570061001008c (13 bytes) 17:25:48.088 CNTRLR [Node 030] [~] [Configuration] 16: 0 => 0 17:25:48.092 SERIAL » [ACK] (0x06) 17:25:48.093 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 0 17:25:48.094 CNTRLR « [Node 030] parameter #16 has value: 0 17:25:48.094 CNTRLR » [Node 030] querying parameter #20 value... 17:25:48.101 SERIAL » 0x010a00131e0370051425f54a (12 bytes) 17:25:48.102 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 245 └─[ConfigurationCCGet] parameter #: 20 17:25:48.103 SERIAL « [ACK] (0x06) 17:25:48.111 SERIAL « 0x0104011301e8 (6 bytes) 17:25:48.112 SERIAL » [ACK] (0x06) 17:25:48.112 DRIVER « [RES] [SendData] was sent: true 17:25:48.127 SERIAL « 0x01070013f50000021c (9 bytes) 17:25:48.128 SERIAL » [ACK] (0x06) 17:25:48.128 DRIVER « [REQ] [SendData] callback id: 245 transmit status: OK 17:25:48.138 SERIAL « 0x010b0004001e05700614010f87 (13 bytes) 17:25:48.143 CNTRLR [Node 030] [~] [Configuration] 20: 15 => 15 17:25:48.143 SERIAL » [ACK] (0x06) 17:25:48.144 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 15 17:25:48.145 CNTRLR « [Node 030] parameter #20 has value: 15 17:25:48.146 CNTRLR » [Node 030] querying parameter #22 value... 17:25:48.149 SERIAL » 0x010a00131e0370051625f64b (12 bytes) 17:25:48.149 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 246 └─[ConfigurationCCGet] parameter #: 22 17:25:48.151 SERIAL « [ACK] (0x06) 17:25:48.157 SERIAL « 0x0104011301e8 (6 bytes) 17:25:48.158 SERIAL » [ACK] (0x06) 17:25:48.159 DRIVER « [RES] [SendData] was sent: true 17:25:48.175 SERIAL « 0x01070013f60000021f (9 bytes) 17:25:48.175 SERIAL » [ACK] (0x06) 17:25:48.175 DRIVER « [REQ] [SendData] callback id: 246 transmit status: OK 17:25:48.186 SERIAL « 0x010c0004001e0670061602001e93 (14 bytes) 17:25:48.191 CNTRLR [Node 030] [~] [Configuration] 22: 30 => 30 17:25:48.191 SERIAL » [ACK] (0x06) 17:25:48.192 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 30 17:25:48.193 CNTRLR « [Node 030] parameter #22 has value: 30 17:25:48.194 CNTRLR » [Node 030] querying parameter #24 value... 17:25:48.197 SERIAL » 0x010a00131e0370051825f744 (12 bytes) 17:25:48.197 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 247 └─[ConfigurationCCGet] parameter #: 24 17:25:48.200 SERIAL « [ACK] (0x06) 17:25:48.206 SERIAL « 0x0104011301e8 (6 bytes) 17:25:48.206 SERIAL » [ACK] (0x06) 17:25:48.208 DRIVER « [RES] [SendData] was sent: true 17:25:48.223 SERIAL « 0x01070013f70000021e (9 bytes) 17:25:48.223 SERIAL » [ACK] (0x06) 17:25:48.224 DRIVER « [REQ] [SendData] callback id: 247 transmit status: OK 17:25:48.233 SERIAL « 0x010b0004001e05700618010084 (13 bytes) 17:25:48.238 CNTRLR [Node 030] [~] [Configuration] 24: 0 => 0 17:25:48.239 SERIAL » [ACK] (0x06) 17:25:48.240 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 24 value size: 1 value: 0 17:25:48.241 CNTRLR « [Node 030] parameter #24 has value: 0 17:25:48.241 CNTRLR » [Node 030] querying parameter #26 value... 17:25:48.245 SERIAL » 0x010a00131e0370051a25f849 (12 bytes) 17:25:48.245 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 248 └─[ConfigurationCCGet] parameter #: 26 17:25:48.247 SERIAL « [ACK] (0x06) 17:25:48.254 SERIAL « 0x0104011301e8 (6 bytes) 17:25:48.255 SERIAL » [ACK] (0x06) 17:25:48.256 DRIVER « [RES] [SendData] was sent: true 17:25:48.270 SERIAL « 0x01070013f800000310 (9 bytes) 17:25:48.270 SERIAL » [ACK] (0x06) 17:25:48.271 DRIVER « [REQ] [SendData] callback id: 248 transmit status: OK 17:25:48.281 SERIAL « 0x010b0004001e0570061a010086 (13 bytes) 17:25:48.286 CNTRLR [Node 030] [~] [Configuration] 26: 0 => 0 17:25:48.286 SERIAL » [ACK] (0x06) 17:25:48.287 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 26 value size: 1 value: 0 17:25:48.288 CNTRLR « [Node 030] parameter #26 has value: 0 17:25:48.289 CNTRLR » [Node 030] querying parameter #40 value... 17:25:48.292 SERIAL » 0x010a00131e0370052825f97a (12 bytes) 17:25:48.292 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 249 └─[ConfigurationCCGet] parameter #: 40 17:25:48.294 SERIAL « [ACK] (0x06) 17:25:48.301 SERIAL « 0x0104011301e8 (6 bytes) 17:25:48.303 SERIAL » [ACK] (0x06) 17:25:48.303 DRIVER « [RES] [SendData] was sent: true 17:25:48.317 SERIAL « 0x01070013f900000210 (9 bytes) 17:25:48.318 SERIAL » [ACK] (0x06) 17:25:48.318 DRIVER « [REQ] [SendData] callback id: 249 transmit status: OK 17:25:48.329 SERIAL « 0x010c0004001e067006280200c87b (14 bytes) 17:25:48.334 CNTRLR [Node 030] [~] [Configuration] 40: 200 => 200 17:25:48.334 SERIAL » [ACK] (0x06) 17:25:48.335 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 2 value: 200 17:25:48.336 CNTRLR « [Node 030] parameter #40 has value: 200 17:25:48.336 CNTRLR » [Node 030] querying parameter #42 value... 17:25:48.343 SERIAL » 0x010a00131e0370052a25fa7b (12 bytes) 17:25:48.343 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 250 └─[ConfigurationCCGet] parameter #: 42 17:25:48.345 SERIAL « [ACK] (0x06) 17:25:48.351 SERIAL « 0x0104011301e8 (6 bytes) 17:25:48.352 SERIAL » [ACK] (0x06) 17:25:48.352 DRIVER « [RES] [SendData] was sent: true 17:25:48.368 SERIAL « 0x01070013fa00000312 (9 bytes) 17:25:48.369 SERIAL » [ACK] (0x06) 17:25:48.369 DRIVER « [REQ] [SendData] callback id: 250 transmit status: OK 17:25:48.380 SERIAL « 0x010c0004001e0670062a020000b1 (14 bytes) 17:25:48.385 CNTRLR [Node 030] [~] [Configuration] 42: 0 => 0 17:25:48.385 SERIAL » [ACK] (0x06) 17:25:48.386 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 0 17:25:48.387 CNTRLR « [Node 030] parameter #42 has value: 0 17:25:48.388 CNTRLR » [Node 030] querying parameter #60 value... 17:25:48.391 SERIAL » 0x010a00131e0370053c25fb6c (12 bytes) 17:25:48.391 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 251 └─[ConfigurationCCGet] parameter #: 60 17:25:48.393 SERIAL « [ACK] (0x06) 17:25:48.399 SERIAL « 0x0104011301e8 (6 bytes) 17:25:48.400 SERIAL » [ACK] (0x06) 17:25:48.401 DRIVER « [RES] [SendData] was sent: true 17:25:48.416 SERIAL « 0x01070013fb00000212 (9 bytes) 17:25:48.417 SERIAL » [ACK] (0x06) 17:25:48.417 DRIVER « [REQ] [SendData] callback id: 251 transmit status: OK 17:25:48.427 SERIAL « 0x010b0004001e0570063c010aaa (13 bytes) 17:25:48.436 CNTRLR [Node 030] [~] [Configuration] 60: 10 => 10 17:25:48.438 SERIAL » [ACK] (0x06) 17:25:48.439 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 1 value: 10 17:25:48.440 CNTRLR « [Node 030] parameter #60 has value: 10 17:25:48.440 CNTRLR » [Node 030] querying parameter #62 value... 17:25:48.443 SERIAL » 0x010a00131e0370053e25fc69 (12 bytes) 17:25:48.444 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 252 └─[ConfigurationCCGet] parameter #: 62 17:25:48.446 SERIAL « [ACK] (0x06) 17:25:48.453 SERIAL « 0x0104011301e8 (6 bytes) 17:25:48.454 SERIAL » [ACK] (0x06) 17:25:48.454 DRIVER « [RES] [SendData] was sent: true 17:25:48.469 SERIAL « 0x01070013fc00000314 (9 bytes) 17:25:48.469 SERIAL » [ACK] (0x06) 17:25:48.470 DRIVER « [REQ] [SendData] callback id: 252 transmit status: OK 17:25:48.480 SERIAL « 0x010c0004001e0670063e02038422 (14 bytes) 17:25:48.485 CNTRLR [Node 030] [~] [Configuration] 62: 900 => 900 17:25:48.486 SERIAL » [ACK] (0x06) 17:25:48.486 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 62 value size: 2 value: 900 17:25:48.488 CNTRLR « [Node 030] parameter #62 has value: 900 17:25:48.488 CNTRLR » [Node 030] querying parameter #64 value... 17:25:48.491 SERIAL » 0x010a00131e0370054025fd16 (12 bytes) 17:25:48.492 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 253 └─[ConfigurationCCGet] parameter #: 64 17:25:48.494 SERIAL « [ACK] (0x06) 17:25:48.501 SERIAL « 0x0104011301e8 (6 bytes) 17:25:48.501 SERIAL » [ACK] (0x06) 17:25:48.502 DRIVER « [RES] [SendData] was sent: true 17:25:48.517 SERIAL « 0x01070013fd00000214 (9 bytes) 17:25:48.517 SERIAL » [ACK] (0x06) 17:25:48.518 DRIVER « [REQ] [SendData] callback id: 253 transmit status: OK 17:25:48.528 SERIAL « 0x010c0004001e06700640020000db (14 bytes) 17:25:48.533 CNTRLR [Node 030] [~] [Configuration] 64: 0 => 0 17:25:48.534 SERIAL » [ACK] (0x06) 17:25:48.535 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 64 value size: 2 value: 0 17:25:48.536 CNTRLR « [Node 030] parameter #64 has value: 0 17:25:48.537 CNTRLR » [Node 030] querying parameter #66 value... 17:25:48.540 SERIAL » 0x010a00131e0370054225fe17 (12 bytes) 17:25:48.540 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 254 └─[ConfigurationCCGet] parameter #: 66 17:25:48.542 SERIAL « [ACK] (0x06) 17:25:48.550 SERIAL « 0x0104011301e8 (6 bytes) 17:25:48.550 SERIAL » [ACK] (0x06) 17:25:48.551 DRIVER « [RES] [SendData] was sent: true 17:25:48.565 SERIAL « 0x01070013fe00000217 (9 bytes) 17:25:48.566 SERIAL » [ACK] (0x06) 17:25:48.566 DRIVER « [REQ] [SendData] callback id: 254 transmit status: OK 17:25:48.577 SERIAL « 0x010c0004001e06700642020000d9 (14 bytes) 17:25:48.582 CNTRLR [Node 030] [~] [Configuration] 66: 0 => 0 17:25:48.582 SERIAL » [ACK] (0x06) 17:25:48.583 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 66 value size: 2 value: 0 17:25:48.584 CNTRLR « [Node 030] parameter #66 has value: 0 17:25:48.585 CNTRLR » [Node 030] querying parameter #80 value... 17:25:48.588 SERIAL » 0x010a00131e0370055025ff04 (12 bytes) 17:25:48.591 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 255 └─[ConfigurationCCGet] parameter #: 80 17:25:48.593 SERIAL « [ACK] (0x06) 17:25:48.599 SERIAL « 0x0104011301e8 (6 bytes) 17:25:48.600 SERIAL » [ACK] (0x06) 17:25:48.600 DRIVER « [RES] [SendData] was sent: true 17:25:48.616 SERIAL « 0x01070013ff00000216 (9 bytes) 17:25:48.617 SERIAL » [ACK] (0x06) 17:25:48.617 DRIVER « [REQ] [SendData] callback id: 255 transmit status: OK 17:25:48.627 SERIAL « 0x010b0004001e057006500100cc (13 bytes) 17:25:48.632 CNTRLR [Node 030] [~] [Configuration] 80: 0 => 0 17:25:48.633 SERIAL » [ACK] (0x06) 17:25:48.633 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 80 value size: 1 value: 0 17:25:48.635 CNTRLR « [Node 030] parameter #80 has value: 0 17:25:48.635 CNTRLR » [Node 030] querying parameter #81 value... 17:25:48.643 SERIAL » 0x010a00131e037005512501fb (12 bytes) 17:25:48.644 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 1 └─[ConfigurationCCGet] parameter #: 81 17:25:48.645 SERIAL « [ACK] (0x06) 17:25:48.652 SERIAL « 0x0104011301e8 (6 bytes) 17:25:48.653 SERIAL » [ACK] (0x06) 17:25:48.653 DRIVER « [RES] [SendData] was sent: true 17:25:48.669 SERIAL « 0x0107001301000003e9 (9 bytes) 17:25:48.669 SERIAL » [ACK] (0x06) 17:25:48.670 DRIVER « [REQ] [SendData] callback id: 1 transmit status: OK 17:25:48.680 SERIAL « 0x010b0004001e057006510132ff (13 bytes) 17:25:48.685 CNTRLR [Node 030] [~] [Configuration] 81: 50 => 50 17:25:48.685 SERIAL » [ACK] (0x06) 17:25:48.686 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 81 value size: 1 value: 50 17:25:48.687 CNTRLR « [Node 030] parameter #81 has value: 50 17:25:48.688 CNTRLR » [Node 030] querying parameter #82 value... 17:25:48.691 SERIAL » 0x010a00131e037005522502fb (12 bytes) 17:25:48.691 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 2 └─[ConfigurationCCGet] parameter #: 82 17:25:48.693 SERIAL « [ACK] (0x06) 17:25:48.699 SERIAL « 0x0104011301e8 (6 bytes) 17:25:48.700 SERIAL » [ACK] (0x06) 17:25:48.701 DRIVER « [RES] [SendData] was sent: true 17:25:48.717 SERIAL « 0x0107001302000002eb (9 bytes) 17:25:48.717 SERIAL » [ACK] (0x06) 17:25:48.718 DRIVER « [REQ] [SendData] callback id: 2 transmit status: OK 17:25:48.728 SERIAL « 0x010c0004001e06700652020064ad (14 bytes) 17:25:48.736 CNTRLR [Node 030] [~] [Configuration] 82: 100 => 100 17:25:48.736 SERIAL » [ACK] (0x06) 17:25:48.737 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 82 value size: 2 value: 100 17:25:48.738 CNTRLR « [Node 030] parameter #82 has value: 100 17:25:48.739 CNTRLR » [Node 030] querying parameter #83 value... 17:25:48.742 SERIAL » 0x010a00131e037005532503fb (12 bytes) 17:25:48.742 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 3 └─[ConfigurationCCGet] parameter #: 83 17:25:48.744 SERIAL « [ACK] (0x06) 17:25:48.750 SERIAL « 0x0104011301e8 (6 bytes) 17:25:48.751 SERIAL » [ACK] (0x06) 17:25:48.751 DRIVER « [RES] [SendData] was sent: true 17:25:48.767 SERIAL « 0x0107001303000002ea (9 bytes) 17:25:48.768 SERIAL » [ACK] (0x06) 17:25:48.768 DRIVER « [REQ] [SendData] callback id: 3 transmit status: OK 17:25:48.779 SERIAL « 0x010c0004001e067006530203e823 (14 bytes) 17:25:48.784 CNTRLR [Node 030] [~] [Configuration] 83: 1000 => 1000 17:25:48.784 SERIAL » [ACK] (0x06) 17:25:48.785 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 83 value size: 2 value: 1000 17:25:48.786 CNTRLR « [Node 030] parameter #83 has value: 1000 17:25:48.786 CNTRLR » [Node 030] querying parameter #86 value... 17:25:48.790 SERIAL » 0x010a00131e037005562504f9 (12 bytes) 17:25:48.790 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 4 └─[ConfigurationCCGet] parameter #: 86 17:25:48.792 SERIAL « [ACK] (0x06) 17:25:48.799 SERIAL « 0x0104011301e8 (6 bytes) 17:25:48.800 SERIAL » [ACK] (0x06) 17:25:48.800 DRIVER « [RES] [SendData] was sent: true 17:25:48.816 SERIAL « 0x0107001304000002ed (9 bytes) 17:25:48.816 SERIAL » [ACK] (0x06) 17:25:48.817 DRIVER « [REQ] [SendData] callback id: 4 transmit status: OK 17:25:48.826 SERIAL « 0x010b0004001e057006560112d8 (13 bytes) 17:25:48.834 CNTRLR [Node 030] [~] [Configuration] 86: 18 => 18 17:25:48.835 SERIAL » [ACK] (0x06) 17:25:48.836 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 86 value size: 1 value: 18 17:25:48.837 CNTRLR « [Node 030] parameter #86 has value: 18 17:25:48.838 CNTRLR » [Node 030] querying parameter #87 value... 17:25:48.842 SERIAL » 0x010a00131e037005572505f9 (12 bytes) 17:25:48.843 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 5 └─[ConfigurationCCGet] parameter #: 87 17:25:48.846 SERIAL « [ACK] (0x06) 17:25:48.851 SERIAL « 0x0104011301e8 (6 bytes) 17:25:48.851 SERIAL » [ACK] (0x06) 17:25:48.852 DRIVER « [RES] [SendData] was sent: true 17:25:48.868 SERIAL « 0x0107001305000002ec (9 bytes) 17:25:48.868 SERIAL » [ACK] (0x06) 17:25:48.869 DRIVER « [REQ] [SendData] callback id: 5 transmit status: OK 17:25:48.879 SERIAL « 0x010b0004001e05700657011cd7 (13 bytes) 17:25:48.886 CNTRLR [Node 030] [~] [Configuration] 87: 28 => 28 17:25:48.887 SERIAL » [ACK] (0x06) 17:25:48.888 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 87 value size: 1 value: 28 17:25:48.890 CNTRLR « [Node 030] parameter #87 has value: 28 17:25:48.890 CNTRLR » [Node 030] querying parameter #89 value... 17:25:48.896 SERIAL » 0x010a00131e037005592506f4 (12 bytes) 17:25:48.896 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 6 └─[ConfigurationCCGet] parameter #: 89 17:25:48.903 SERIAL « 0x010c00040003063105042204cb2f (14 bytes) 17:25:48.904 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:25:48.904 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 253.3 => 122.7 [Endpoint 0] 17:25:48.905 SERIAL » [ACK] (0x06) 17:25:48.906 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 122.7 17:25:48.907 SERIAL « [CAN] (0x18) 17:25:48.908 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 17:25:49.009 SERIAL » 0x010a00131e037005592506f4 (12 bytes) 17:25:49.009 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 6 └─[ConfigurationCCGet] parameter #: 89 17:25:49.011 SERIAL « [ACK] (0x06) 17:25:49.017 SERIAL « 0x0104011301e8 (6 bytes) 17:25:49.018 SERIAL » [ACK] (0x06) 17:25:49.018 DRIVER « [RES] [SendData] was sent: true 17:25:49.035 SERIAL « 0x0107001306000002ef (9 bytes) 17:25:49.035 SERIAL » [ACK] (0x06) 17:25:49.036 DRIVER « [REQ] [SendData] callback id: 6 transmit status: OK 17:25:49.046 SERIAL « 0x010b0004001e057006590101c4 (13 bytes) 17:25:49.051 CNTRLR [Node 030] [~] [Configuration] 89: 1 => 1 17:25:49.053 SERIAL » [ACK] (0x06) 17:25:49.053 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 89 value size: 1 value: 1 17:25:49.059 CNTRLR « [Node 030] parameter #89 has value: 1 17:25:49.060 CNTRLR [Node 030] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:25:49.097 CNTRLR [Node 030] AlarmSensorCC: doing a partial interview... 17:25:49.098 CNTRLR » [Node 030] querying current value for General Purpose... 17:25:49.140 SERIAL » 0x010a00131e039c0100250744 (12 bytes) 17:25:49.141 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 7 └─[AlarmSensorCCGet] sensor type: General Purpose 17:25:49.145 SERIAL « [ACK] (0x06) 17:25:49.149 SERIAL « 0x0104011301e8 (6 bytes) 17:25:49.149 SERIAL » [ACK] (0x06) 17:25:49.150 DRIVER « [RES] [SendData] was sent: true 17:25:49.166 SERIAL « 0x0107001307000002ee (9 bytes) 17:25:49.166 SERIAL » [ACK] (0x06) 17:25:49.167 DRIVER « [REQ] [SendData] callback id: 7 transmit status: OK 17:25:49.177 SERIAL « 0x010d0004001e079c021e000000006f (15 bytes) 17:25:49.179 CNTRLR [Node 030] [~] [Alarm Sensor] state[0]: false => false [Endpoint 0] 17:25:49.180 CNTRLR [Node 030] [+] [Alarm Sensor] severity[0]: undefined [Endpoint 0] 17:25:49.181 CNTRLR [Node 030] [+] [Alarm Sensor] duration[0]: undefined [Endpoint 0] 17:25:49.181 SERIAL » [ACK] (0x06) 17:25:49.183 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: false 17:25:49.185 CNTRLR « [Node 030] received current value for General Purpose: state: false 17:25:49.185 CNTRLR [Node 030] [~] [Alarm Sensor] interviewComplete: true [Endpoint 0] [internal] => true 17:25:49.185 CNTRLR [Node 030] MultiChannelAssociationCC: doing a partial interview... 17:25:49.185 CNTRLR » [Node 030] querying multi channel association group #1... 17:25:49.189 SERIAL » 0x010a00131e038e020125085b (12 bytes) 17:25:49.190 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 8 └─[MultiChannelAssociationCCGet] group id: 1 17:25:49.192 SERIAL « [ACK] (0x06) 17:25:49.198 SERIAL « 0x0104011301e8 (6 bytes) 17:25:49.198 SERIAL » [ACK] (0x06) 17:25:49.199 DRIVER « [RES] [SendData] was sent: true 17:25:49.215 SERIAL « 0x0107001308000002e1 (9 bytes) 17:25:49.215 SERIAL » [ACK] (0x06) 17:25:49.216 DRIVER « [REQ] [SendData] callback id: 8 transmit status: OK 17:25:49.226 SERIAL « 0x010c0004001e068e030105000167 (14 bytes) 17:25:49.227 SERIAL » [ACK] (0x06) 17:25:49.227 CNTRLR [Node 030] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 17:25:49.228 CNTRLR [Node 030] [~] [Multi Channel Association] nodeIds[1]: 1 => 1 17:25:49.229 CNTRLR [Node 030] [~] [Multi Channel Association] endpoints[1]: => 17:25:49.230 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: 1 endpoints: 17:25:49.231 CNTRLR « [Node 030] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 17:25:49.232 CNTRLR » [Node 030] querying multi channel association group #2... 17:25:49.236 SERIAL » 0x010a00131e038e0202250959 (12 bytes) 17:25:49.236 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 9 └─[MultiChannelAssociationCCGet] group id: 2 17:25:49.238 SERIAL « [ACK] (0x06) 17:25:49.247 SERIAL « 0x0104011301e8 (6 bytes) 17:25:49.248 SERIAL » [ACK] (0x06) 17:25:49.249 DRIVER « [RES] [SendData] was sent: true 17:25:49.261 SERIAL « 0x0107001309000002e0 (9 bytes) 17:25:49.261 SERIAL » [ACK] (0x06) 17:25:49.262 DRIVER « [REQ] [SendData] callback id: 9 transmit status: OK 17:25:49.272 SERIAL « 0x010c0004001e068e030205000164 (14 bytes) 17:25:49.273 SERIAL » [ACK] (0x06) 17:25:49.273 CNTRLR [Node 030] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 17:25:49.274 CNTRLR [Node 030] [~] [Multi Channel Association] nodeIds[2]: 1 => 1 17:25:49.275 CNTRLR [Node 030] [~] [Multi Channel Association] endpoints[2]: => 17:25:49.276 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: 1 endpoints: 17:25:49.277 CNTRLR « [Node 030] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 17:25:49.277 CNTRLR » [Node 030] querying additional non-multi-channel association groups... 17:25:49.277 CNTRLR » [Node 030] querying association group #3... 17:25:49.281 SERIAL » 0x010a00131e03850203250a50 (12 bytes) 17:25:49.282 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 10 └─[AssociationCCGet] group id: 3 17:25:49.284 SERIAL « [ACK] (0x06) 17:25:49.291 SERIAL « 0x0104011301e8 (6 bytes) 17:25:49.291 SERIAL » [ACK] (0x06) 17:25:49.292 DRIVER « [RES] [SendData] was sent: true 17:25:49.308 SERIAL « 0x010700130a000002e3 (9 bytes) 17:25:49.309 SERIAL » [ACK] (0x06) 17:25:49.309 DRIVER « [REQ] [SendData] callback id: 10 transmit status: OK 17:25:49.318 SERIAL « 0x010c0004001e068503030100016a (14 bytes) 17:25:49.319 SERIAL » [ACK] (0x06) 17:25:49.320 CNTRLR [Node 030] [~] [Association] maxNodes[3]: 1 => 1 [internal] 17:25:49.320 CNTRLR [Node 030] [~] [Association] nodeIds[3]: 1 => 1 [internal] 17:25:49.320 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 17:25:49.321 CNTRLR « [Node 030] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 17:25:49.322 CNTRLR [Node 030] [~] [Association] hasLifeline: true => true [internal] 17:25:49.322 CNTRLR [Node 030] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:25:49.351 CNTRLR [Node 030] Interview stage completed: CommandClasses 17:25:49.351 CNTRLR [Node 030] Interview stage completed: OverwriteConfig 17:25:49.351 CNTRLR » [Node 030] requesting node neighbors... 17:25:49.355 SERIAL » 0x010700801e00000066 (9 bytes) 17:25:49.355 DRIVER » [Node 030] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:25:49.356 SERIAL « [ACK] (0x06) 17:25:49.359 SERIAL « 0x0120018065e984030000000000000000000000000000000000000000000000000 (34 bytes) 055 17:25:49.360 SERIAL » [ACK] (0x06) 17:25:49.360 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 7, 9, 12, 14, 15, 16, 19, 24, 25, 26 17:25:49.362 CNTRLR « [Node 030] node neighbors received: 1, 3, 6, 7, 9, 12, 14, 15, 16, 19, 24, 2 5, 26 17:25:49.363 CNTRLR [Node 030] Interview stage completed: Neighbors 17:25:49.363 CNTRLR [Node 030] Interview completed 17:25:50.364 CNTRLR » [Node 030] Sending node back to sleep... 17:25:50.368 SERIAL » 0x010900131e028408250b5b (11 bytes) 17:25:50.368 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 11 └─[WakeUpCCNoMoreInformation] 17:25:50.370 SERIAL « [ACK] (0x06) 17:25:50.376 SERIAL « 0x0104011301e8 (6 bytes) 17:25:50.376 SERIAL » [ACK] (0x06) 17:25:50.377 DRIVER « [RES] [SendData] was sent: true 17:25:50.393 SERIAL « 0x010700130b000002e2 (9 bytes) 17:25:50.393 SERIAL » [ACK] (0x06) 17:25:50.394 DRIVER « [REQ] [SendData] callback id: 11 transmit status: OK 17:25:50.396 CNTRLR [Node 030] The node is now asleep. 17:25:54.885 SERIAL « 0x010c00040003063105042208ad45 (14 bytes) 17:25:54.887 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:25:54.888 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 122.7 => 222.1 [Endpoint 0] 17:25:54.889 SERIAL » [ACK] (0x06) 17:25:54.891 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 222.1 17:25:55.885 SERIAL « 0x010c0004000306310504220759be (14 bytes) 17:25:55.885 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:25:55.886 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 222.1 => 188.1 [Endpoint 0] 17:25:55.886 SERIAL » [ACK] (0x06) 17:25:55.887 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 188.1 17:26:21.757 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 17:26:21.758 SERIAL » [ACK] (0x06) 17:26:21.759 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 17:26:21.762 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 17:26:25.888 SERIAL « 0x010c00040003063105042203ea09 (14 bytes) 17:26:25.890 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:26:25.891 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 188.1 => 100.2 [Endpoint 0] 17:26:25.893 SERIAL » [ACK] (0x06) 17:26:25.895 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 100.2 17:26:26.888 SERIAL « 0x010c0004000306310504220718ff (14 bytes) 17:26:26.890 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:26:26.891 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 100.2 => 181.6 [Endpoint 0] 17:26:26.893 SERIAL » [ACK] (0x06) 17:26:26.895 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 181.6 17:26:27.888 SERIAL « 0x010c00040003063105042208a34b (14 bytes) 17:26:27.889 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:26:27.890 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 181.6 => 221.1 [Endpoint 0] 17:26:27.890 SERIAL » [ACK] (0x06) 17:26:27.891 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 221.1 17:26:29.889 SERIAL « 0x010c00040003063105042206a345 (14 bytes) 17:26:29.889 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:26:29.890 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 221.1 => 169.9 [Endpoint 0] 17:26:29.891 SERIAL » [ACK] (0x06) 17:26:29.893 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 169.9 17:26:30.889 SERIAL « 0x010c000400030631050422099c75 (14 bytes) 17:26:30.889 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:26:30.890 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 169.9 => 246 [Endpoint 0] 17:26:30.890 SERIAL » [ACK] (0x06) 17:26:30.892 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 246 17:26:39.814 SERIAL « 0x01090004001e033003ff23 (11 bytes) 17:26:39.816 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:26:39.818 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:26:39.819 SERIAL » [ACK] (0x06) 17:26:39.822 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:26:39.868 SERIAL « 0x01090004001e032001ff31 (11 bytes) 17:26:39.870 SERIAL » [ACK] (0x06) 17:26:39.875 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:26:39.879 CNTRLR [Node 030] treating BasicCC Set as a report 17:26:39.880 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:26:46.891 SERIAL « 0x010c000400030631050422077691 (14 bytes) 17:26:46.892 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:26:46.894 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 246 => 191 [Endpoint 0] 17:26:46.895 SERIAL » [ACK] (0x06) 17:26:46.897 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 191 17:26:53.891 SERIAL « 0x010c000400030631050422093fd6 (14 bytes) 17:26:53.892 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:26:53.892 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 191 => 236.7 [Endpoint 0] 17:26:53.893 SERIAL » [ACK] (0x06) 17:26:53.894 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 236.7 17:26:57.892 SERIAL « 0x010c00040003063105042207ca2d (14 bytes) 17:26:57.894 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:26:57.895 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 236.7 => 199.4 [Endpoint 0] 17:26:57.896 SERIAL » [ACK] (0x06) 17:26:57.899 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 199.4 17:27:00.892 SERIAL « 0x010c000400030631050422039172 (14 bytes) 17:27:00.893 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:27:00.895 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 199.4 => 91.3 [Endpoint 0] 17:27:00.896 SERIAL » [ACK] (0x06) 17:27:00.898 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 91.3 17:27:01.892 SERIAL « 0x010c00040003063105042207f611 (14 bytes) 17:27:01.893 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:27:01.895 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 91.3 => 203.8 [Endpoint 0] 17:27:01.896 SERIAL » [ACK] (0x06) 17:27:01.898 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 203.8 17:27:10.591 SERIAL « 0x01090004001e03300300dc (11 bytes) 17:27:10.592 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:27:10.594 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:27:10.595 SERIAL » [ACK] (0x06) 17:27:10.606 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:27:10.645 SERIAL « 0x01090004001e03200100ce (11 bytes) 17:27:10.646 SERIAL » [ACK] (0x06) 17:27:10.648 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:27:10.651 CNTRLR [Node 030] treating BasicCC Set as a report 17:27:10.652 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:27:17.530 SERIAL « 0x01090004001e033003ff23 (11 bytes) 17:27:17.532 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:27:17.533 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:27:17.535 SERIAL » [ACK] (0x06) 17:27:17.537 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:27:17.585 SERIAL « 0x01090004001e032001ff31 (11 bytes) 17:27:17.586 SERIAL » [ACK] (0x06) 17:27:17.587 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:27:17.590 CNTRLR [Node 030] treating BasicCC Set as a report 17:27:17.590 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:27:17.893 SERIAL « 0x010c00040003063105042204c125 (14 bytes) 17:27:17.895 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:27:17.896 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 203.8 => 121.7 [Endpoint 0] 17:27:17.897 SERIAL » [ACK] (0x06) 17:27:17.899 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 121.7 17:27:21.515 SERIAL « 0x01090004001b033003ff26 (11 bytes) 17:27:21.516 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:27:21.517 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:27:21.518 SERIAL » [ACK] (0x06) 17:27:21.520 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:27:21.569 SERIAL « 0x01090004001b032001ff34 (11 bytes) 17:27:21.571 SERIAL » [ACK] (0x06) 17:27:21.572 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:27:21.575 CNTRLR [Node 027] treating BasicCC Set as a report 17:27:21.575 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:27:23.894 SERIAL « 0x010c00040003063105042207ff18 (14 bytes) 17:27:23.895 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:27:23.896 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 121.7 => 204.7 [Endpoint 0] 17:27:23.897 SERIAL » [ACK] (0x06) 17:27:23.902 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 204.7 17:27:26.894 SERIAL « 0x010c000400030631050422068b6d (14 bytes) 17:27:26.895 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:27:26.896 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 204.7 => 167.5 [Endpoint 0] 17:27:26.897 SERIAL » [ACK] (0x06) 17:27:26.898 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 167.5 17:27:27.893 SERIAL « 0x010c000400030631050422052ecb (14 bytes) 17:27:27.893 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:27:27.894 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 167.5 => 132.6 [Endpoint 0] 17:27:27.895 SERIAL » [ACK] (0x06) 17:27:27.896 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 132.6 17:27:31.895 SERIAL « 0x010c00040003063105042207f710 (14 bytes) 17:27:31.897 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:27:31.899 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 132.6 => 203.9 [Endpoint 0] 17:27:31.900 SERIAL » [ACK] (0x06) 17:27:31.903 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 203.9 17:27:36.931 SERIAL « 0x010c00040002063105030a0014da (14 bytes) 17:27:36.932 CNTRLR [Node 002] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 17:27:36.932 CNTRLR [Node 002] [~] [Multilevel Sensor] Illuminance: 22 => 20 [Endpoint 0] 17:27:36.933 SERIAL » [ACK] (0x06) 17:27:36.935 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 20 17:27:46.082 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 17:27:46.083 SERIAL » [ACK] (0x06) 17:27:46.086 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  17:27:46.090 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 17:27:47.416 SERIAL « 0x01090004001e03300300dc (11 bytes) 17:27:47.417 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:27:47.419 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:27:47.420 SERIAL » [ACK] (0x06) 17:27:47.422 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:27:47.470 SERIAL « 0x01090004001e03200100ce (11 bytes) 17:27:47.472 SERIAL » [ACK] (0x06) 17:27:47.473 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:27:47.477 CNTRLR [Node 030] treating BasicCC Set as a report 17:27:47.478 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:27:47.738 SERIAL « 0x01090004001e033003ff23 (11 bytes) 17:27:47.740 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:27:47.741 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:27:47.743 SERIAL » [ACK] (0x06) 17:27:47.745 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:27:47.793 SERIAL « 0x01090004001e032001ff31 (11 bytes) 17:27:47.794 SERIAL » [ACK] (0x06) 17:27:47.795 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:27:47.799 CNTRLR [Node 030] treating BasicCC Set as a report 17:27:47.799 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:27:47.950 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 17:27:47.951 SERIAL » [ACK] (0x06) 17:27:47.952 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 17:27:47.962 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 17:27:49.897 SERIAL « 0x010c000400030631050422065dbb (14 bytes) 17:27:49.898 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:27:49.899 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 203.9 => 162.9 [Endpoint 0] 17:27:49.900 SERIAL » [ACK] (0x06) 17:27:49.902 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 162.9 17:27:51.897 SERIAL « 0x010c00040003063105042207d532 (14 bytes) 17:27:51.898 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:27:51.900 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 162.9 => 200.5 [Endpoint 0] 17:27:51.901 SERIAL » [ACK] (0x06) 17:27:51.903 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 200.5 17:27:55.898 SERIAL « 0x010c0004000306310504220430d4 (14 bytes) 17:27:55.899 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:27:55.899 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 200.5 => 107.2 [Endpoint 0] 17:27:55.900 SERIAL » [ACK] (0x06) 17:27:55.901 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 107.2 17:27:57.897 SERIAL « 0x010c00040003063105042208e901 (14 bytes) 17:27:57.900 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:27:57.902 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 107.2 => 228.1 [Endpoint 0] 17:27:57.903 SERIAL » [ACK] (0x06) 17:27:57.905 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 228.1 17:27:58.897 SERIAL « 0x010c0004000306310504220707e0 (14 bytes) 17:27:58.899 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:27:58.900 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 228.1 => 179.9 [Endpoint 0] 17:27:58.900 SERIAL » [ACK] (0x06) 17:27:58.902 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 179.9 17:28:09.680 SERIAL « 0x01090004001b03300300d9 (11 bytes) 17:28:09.680 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:28:09.681 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:28:09.682 SERIAL » [ACK] (0x06) 17:28:09.683 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:28:09.734 SERIAL « 0x01090004001b03200100cb (11 bytes) 17:28:09.735 SERIAL » [ACK] (0x06) 17:28:09.735 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:28:09.737 CNTRLR [Node 027] treating BasicCC Set as a report 17:28:09.737 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:28:15.570 SERIAL « 0x01090004001b033003ff26 (11 bytes) 17:28:15.571 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:28:15.571 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:28:15.572 SERIAL » [ACK] (0x06) 17:28:15.573 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:28:15.633 SERIAL « 0x01090004001b032001ff34 (11 bytes) 17:28:15.633 SERIAL » [ACK] (0x06) 17:28:15.634 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:28:15.636 CNTRLR [Node 027] treating BasicCC Set as a report 17:28:15.636 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:28:19.899 SERIAL « 0x010c000400030631050422045bbf (14 bytes) 17:28:19.900 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:28:19.901 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 179.9 => 111.5 [Endpoint 0] 17:28:19.901 SERIAL » [ACK] (0x06) 17:28:19.902 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 111.5 17:28:36.901 SERIAL « 0x010c0004000306310504220918f1 (14 bytes) 17:28:36.902 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:28:36.903 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 111.5 => 232.8 [Endpoint 0] 17:28:36.904 SERIAL » [ACK] (0x06) 17:28:36.906 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 232.8 17:28:39.191 SERIAL « 0x01090004001e03300300dc (11 bytes) 17:28:39.193 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:28:39.193 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:28:39.194 SERIAL » [ACK] (0x06) 17:28:39.196 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:28:39.239 SERIAL « 0x01090004001e03200100ce (11 bytes) 17:28:39.240 SERIAL » [ACK] (0x06) 17:28:39.240 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:28:39.242 CNTRLR [Node 030] treating BasicCC Set as a report 17:28:39.243 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:28:39.902 SERIAL « 0x010c000400030631050422078562 (14 bytes) 17:28:39.903 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:28:39.908 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 232.8 => 192.5 [Endpoint 0] 17:28:39.909 SERIAL » [ACK] (0x06) 17:28:39.911 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 192.5 17:28:39.948 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 17:28:39.951 SERIAL » [ACK] (0x06) 17:28:39.954 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  17:28:39.957 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 17:28:42.902 SERIAL « 0x010c00040003063105042203ea09 (14 bytes) 17:28:42.904 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:28:42.905 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 192.5 => 100.2 [Endpoint 0] 17:28:42.906 SERIAL » [ACK] (0x06) 17:28:42.908 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 100.2 17:28:43.902 SERIAL « 0x010c00040003063105042208628a (14 bytes) 17:28:43.910 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:28:43.911 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 100.2 => 214.6 [Endpoint 0] 17:28:43.912 SERIAL » [ACK] (0x06) 17:28:43.915 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 214.6 17:28:44.361 SERIAL « 0x0110000400120a600d02003105012200a72c (18 bytes) 17:28:44.364 CNTRLR [Node 018] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 17:28:44.366 CNTRLR [Node 018] [~] [Multilevel Sensor] Air temperature: 16.9 => 16.7 [Endpoint 2] 17:28:44.367 SERIAL » [ACK] (0x06) 17:28:44.372 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 16.7 17:28:44.891 SERIAL « 0x01080004000702840775 (10 bytes) 17:28:44.892 SERIAL » [ACK] (0x06) 17:28:44.894 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:28:44.897 CNTRLR « [Node 007] received wakeup notification 17:28:44.898 CNTRLR [Node 007] The node is now awake. 17:28:45.875 SERIAL « 0x01090004001b03300300d9 (11 bytes) 17:28:45.877 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:28:45.878 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:28:45.879 SERIAL » [ACK] (0x06) 17:28:45.881 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:28:45.899 CNTRLR » [Node 007] Sending node back to sleep... 17:28:45.913 SERIAL » 0x0109001307028408250c45 (11 bytes) 17:28:45.914 DRIVER » [Node 007] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 12 └─[WakeUpCCNoMoreInformation] 17:28:45.917 SERIAL « [ACK] (0x06) 17:28:45.922 SERIAL « 0x0104011301e8 (6 bytes) 17:28:45.923 SERIAL » [ACK] (0x06) 17:28:45.925 DRIVER « [RES] [SendData] was sent: true 17:28:45.930 SERIAL « 0x01090004001b03200100cb (11 bytes) 17:28:45.931 SERIAL » [ACK] (0x06) 17:28:45.933 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:28:45.936 CNTRLR [Node 027] treating BasicCC Set as a report 17:28:45.937 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:28:46.007 SERIAL « 0x010700130c000009ee (9 bytes) 17:28:46.008 SERIAL » [ACK] (0x06) 17:28:46.008 DRIVER « [REQ] [SendData] callback id: 12 transmit status: OK 17:28:46.014 CNTRLR [Node 007] The node is now asleep. 17:28:51.903 SERIAL « 0x010c0004000306310504220422c6 (14 bytes) 17:28:51.905 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:28:51.906 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 214.6 => 105.8 [Endpoint 0] 17:28:51.907 SERIAL » [ACK] (0x06) 17:28:51.909 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 105.8 17:28:52.353 SERIAL « 0x01080004102002840742 (10 bytes) 17:28:52.354 SERIAL » [ACK] (0x06) 17:28:52.356 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:28:52.359 CNTRLR « [Node 032] received wakeup notification 17:28:52.360 CNTRLR [Node 032] The node is now awake. 17:28:52.368 SERIAL » 0x0109001320028002250d6d (11 bytes) 17:28:52.369 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 13 └─[BatteryCCGet] 17:28:52.373 SERIAL « [ACK] (0x06) 17:28:52.378 SERIAL « 0x0104011301e8 (6 bytes) 17:28:52.379 SERIAL » [ACK] (0x06) 17:28:52.381 DRIVER « [RES] [SendData] was sent: true 17:28:52.417 SERIAL « 0x010700130d000004e2 (9 bytes) 17:28:52.419 SERIAL » [ACK] (0x06) 17:28:52.420 DRIVER « [REQ] [SendData] callback id: 13 transmit status: OK 17:28:52.464 SERIAL « 0x0109000400200380036436 (11 bytes) 17:28:52.465 CNTRLR [Node 032] [~] [Battery] level: 100 => 100 [Endpoint 0] 17:28:52.466 CNTRLR [Node 032] [~] [Battery] isLow: false => false [Endpoint 0] 17:28:52.466 SERIAL » [ACK] (0x06) 17:28:52.468 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 17:28:52.473 CNTRLR « [Node 032] received response for battery information: level: 100 17:28:52.473 CNTRLR [Node 032] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:28:52.528 CNTRLR [Node 032] WakeUpCC: doing a partial interview... 17:28:52.528 CNTRLR » [Node 032] retrieving wakeup interval from the device... 17:28:52.535 SERIAL » 0x0109001320028405250e6d (11 bytes) 17:28:52.536 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 14 └─[WakeUpCCIntervalGet] 17:28:52.537 SERIAL « 0x01080004102002840742 (10 bytes) 17:28:52.538 SERIAL » [ACK] (0x06) 17:28:52.539 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:28:52.540 CNTRLR « [Node 032] received wakeup notification 17:28:52.541 SERIAL « [CAN] (0x18) 17:28:52.542 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 17:28:52.643 SERIAL » 0x0109001320028405250e6d (11 bytes) 17:28:52.644 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 14 └─[WakeUpCCIntervalGet] 17:28:52.645 SERIAL « [ACK] (0x06) 17:28:52.652 SERIAL « 0x0104011301e8 (6 bytes) 17:28:52.652 SERIAL » [ACK] (0x06) 17:28:52.653 DRIVER « [RES] [SendData] was sent: true 17:28:52.690 SERIAL « 0x010700130e000005e0 (9 bytes) 17:28:52.691 SERIAL » [ACK] (0x06) 17:28:52.691 DRIVER « [REQ] [SendData] callback id: 14 transmit status: OK 17:28:52.739 SERIAL « 0x010c0004002006840600038401d5 (14 bytes) 17:28:52.740 CNTRLR [Node 032] [~] [Wake Up] wakeUpInterval: 900 => 900 [Endpoint 0] 17:28:52.741 CNTRLR [Node 032] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 17:28:52.741 SERIAL » [ACK] (0x06) 17:28:52.743 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 900 seconds controller node id: 1 17:28:52.745 CNTRLR « [Node 032] received wakeup configuration: wakeup interval: 900 seconds controller node: 1 17:28:52.745 CNTRLR [Node 032] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:28:52.793 SERIAL « 0x01080004102002840742 (10 bytes) 17:28:52.794 SERIAL » [ACK] (0x06) 17:28:52.795 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:28:52.796 CNTRLR « [Node 032] received wakeup notification 17:28:52.798 CNTRLR [Node 032] AssociationCC: doing a partial interview... 17:28:52.798 CNTRLR [Node 032] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:28:52.798 CNTRLR [Node 032] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:28:52.799 CNTRLR [Node 032] BasicCC: doing a partial interview... 17:28:52.799 CNTRLR » [Node 032] querying Basic CC state... 17:28:52.803 SERIAL » 0x0109001320022002250fcf (11 bytes) 17:28:52.804 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 15 └─[BasicCCGet] 17:28:52.806 SERIAL « 0x01080004102002840742 (10 bytes) 17:28:52.807 SERIAL » [ACK] (0x06) 17:28:52.807 SERIAL « [CAN] (0x18) 17:28:52.808 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 17:28:52.809 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:28:52.811 CNTRLR « [Node 032] received wakeup notification 17:28:52.814 SERIAL « 0x01080004102002840742 (10 bytes) 17:28:52.814 SERIAL » [ACK] (0x06) 17:28:52.815 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:28:52.816 CNTRLR « [Node 032] received wakeup notification 17:28:52.881 SERIAL « 0x01080004102002840742 (10 bytes) 17:28:52.881 SERIAL » [ACK] (0x06) 17:28:52.882 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:28:52.885 CNTRLR « [Node 032] received wakeup notification 17:28:52.910 SERIAL » 0x0109001320022002250fcf (11 bytes) 17:28:52.910 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 15 └─[BasicCCGet] 17:28:52.912 SERIAL « [ACK] (0x06) 17:28:52.919 SERIAL « 0x0104011301e8 (6 bytes) 17:28:52.919 SERIAL » [ACK] (0x06) 17:28:52.920 DRIVER « [RES] [SendData] was sent: true 17:28:52.996 SERIAL « 0x010700130f000006e2 (9 bytes) 17:28:52.997 SERIAL » [ACK] (0x06) 17:28:52.998 DRIVER « [REQ] [SendData] callback id: 15 transmit status: OK 17:28:53.012 SERIAL « 0x01080004102002840742 (10 bytes) 17:28:53.012 SERIAL » [ACK] (0x06) 17:28:53.013 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:28:53.015 CNTRLR « [Node 032] received wakeup notification 17:28:53.096 SERIAL « 0x010900040020032003ff0d (11 bytes) 17:28:53.097 SERIAL » [ACK] (0x06) 17:28:53.098 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCReport] current value: 99 17:28:53.099 CNTRLR « [Node 032] received Basic CC state: current value: 99 17:28:53.100 CNTRLR [Node 032] [~] [Basic] interviewComplete: true => true [Endpoint 0] [internal] 17:28:53.100 CNTRLR [Node 032] BinarySensorCC: doing a partial interview... 17:28:53.100 CNTRLR » [Node 032] querying current value... 17:28:53.105 SERIAL » 0x01090013200230022510c0 (11 bytes) 17:28:53.105 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[BinarySensorCCGet] type: Any 17:28:53.107 SERIAL « [ACK] (0x06) 17:28:53.114 SERIAL « 0x0104011301e8 (6 bytes) 17:28:53.114 SERIAL » [ACK] (0x06) 17:28:53.114 DRIVER « [RES] [SendData] was sent: true 17:28:53.328 SERIAL « 0x0107001310000016ed (9 bytes) 17:28:53.328 SERIAL » [ACK] (0x06) 17:28:53.330 DRIVER « [REQ] [SendData] callback id: 16 transmit status: OK 17:28:53.369 SERIAL « 0x010900040020033003ff1d (11 bytes) 17:28:53.369 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:28:53.370 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:28:53.370 SERIAL » [ACK] (0x06) 17:28:53.372 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:28:53.373 CNTRLR « [Node 032] received current value: true 17:28:53.374 CNTRLR [Node 032] [~] [Binary Sensor] interviewComplete: true [Endpoint 0] [internal] => true 17:28:53.374 CNTRLR [Node 032] MultilevelSensorCC: doing a partial interview... 17:28:53.375 CNTRLR » [Node 032] querying Air temperature sensor reading... 17:28:53.379 SERIAL » 0x010b00132004310401002511c3 (13 bytes) 17:28:53.379 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 17 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 17:28:53.382 SERIAL « [ACK] (0x06) 17:28:53.389 SERIAL « 0x0104011301e8 (6 bytes) 17:28:53.390 SERIAL » [ACK] (0x06) 17:28:53.391 DRIVER « [RES] [SendData] was sent: true 17:28:53.492 SERIAL « 0x010700131100000bf1 (9 bytes) 17:28:53.494 SERIAL » [ACK] (0x06) 17:28:53.497 DRIVER « [REQ] [SendData] callback id: 17 transmit status: OK 17:28:53.568 SERIAL « 0x010c00040020063105012200b573 (14 bytes) 17:28:53.569 CNTRLR [Node 032] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 17:28:53.570 CNTRLR [Node 032] [~] [Multilevel Sensor] Air temperature: 19.7 => 18.1 [Endpoint 0] 17:28:53.570 SERIAL » [ACK] (0x06) 17:28:53.573 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.1 17:28:53.575 CNTRLR « [Node 032] received current Air temperature sensor reading: 18.1 °C 17:28:53.575 CNTRLR » [Node 032] querying Illuminance sensor reading... 17:28:53.581 SERIAL » 0x010b00132004310403082512ca (13 bytes) 17:28:53.581 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 18 └─[MultilevelSensorCCGet] sensor type: Illuminance scale: Lux 17:28:53.584 SERIAL « [ACK] (0x06) 17:28:53.589 SERIAL « 0x0104011301e8 (6 bytes) 17:28:53.590 SERIAL » [ACK] (0x06) 17:28:53.590 DRIVER « [RES] [SendData] was sent: true 17:28:53.662 SERIAL « 0x0107001312000008f1 (9 bytes) 17:28:53.663 SERIAL » [ACK] (0x06) 17:28:53.663 DRIVER « [REQ] [SendData] callback id: 18 transmit status: OK 17:28:53.713 SERIAL « 0x010c00040020063105030a0017fb (14 bytes) 17:28:53.714 CNTRLR [Node 032] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 17:28:53.714 CNTRLR [Node 032] [~] [Multilevel Sensor] Illuminance: 5 => 23 [Endpoint 0] 17:28:53.715 SERIAL » [ACK] (0x06) 17:28:53.716 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 23 17:28:53.718 CNTRLR « [Node 032] received current Illuminance sensor reading: 23 Lux 17:28:53.718 CNTRLR [Node 032] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 17:28:53.718 CNTRLR [Node 032] ConfigurationCC: Loading configuration parameters from device confi g 17:28:53.725 CNTRLR [Node 032] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:28:53.726 CNTRLR [Node 032] [Configuration] 1: metadata updated 17:28:53.727 CNTRLR [Node 032] [Configuration] 2: metadata updated 17:28:53.728 CNTRLR [Node 032] [Configuration] 3: metadata updated 17:28:53.729 CNTRLR [Node 032] [Configuration] 4: metadata updated 17:28:53.730 CNTRLR [Node 032] [Configuration] 6: metadata updated 17:28:53.731 CNTRLR [Node 032] [Configuration] 8: metadata updated 17:28:53.732 CNTRLR [Node 032] [Configuration] 9: metadata updated 17:28:53.733 CNTRLR [Node 032] [Configuration] 12: metadata updated 17:28:53.734 CNTRLR [Node 032] [Configuration] 14: metadata updated 17:28:53.736 CNTRLR [Node 032] [Configuration] 16: metadata updated 17:28:53.737 CNTRLR [Node 032] [Configuration] 20: metadata updated 17:28:53.738 CNTRLR [Node 032] [Configuration] 22: metadata updated 17:28:53.739 CNTRLR [Node 032] [Configuration] 24: metadata updated 17:28:53.740 CNTRLR [Node 032] [Configuration] 26: metadata updated 17:28:53.741 CNTRLR [Node 032] [Configuration] 40: metadata updated 17:28:53.742 CNTRLR [Node 032] [Configuration] 42: metadata updated 17:28:53.743 CNTRLR [Node 032] [Configuration] 60: metadata updated 17:28:53.744 CNTRLR [Node 032] [Configuration] 62: metadata updated 17:28:53.745 CNTRLR [Node 032] [Configuration] 64: metadata updated 17:28:53.746 CNTRLR [Node 032] [Configuration] 66: metadata updated 17:28:53.748 CNTRLR [Node 032] [Configuration] 80: metadata updated 17:28:53.749 CNTRLR [Node 032] [Configuration] 81: metadata updated 17:28:53.750 CNTRLR [Node 032] [Configuration] 82: metadata updated 17:28:53.751 CNTRLR [Node 032] [Configuration] 83: metadata updated 17:28:53.752 CNTRLR [Node 032] [Configuration] 86: metadata updated 17:28:53.753 CNTRLR [Node 032] [Configuration] 87: metadata updated 17:28:53.754 CNTRLR [Node 032] [Configuration] 89: metadata updated 17:28:53.756 CNTRLR [Node 032] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:28:53.757 CNTRLR » [Node 032] querying parameter #1 value... 17:28:53.763 SERIAL » 0x010a00132003700501251387 (12 bytes) 17:28:53.763 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 19 └─[ConfigurationCCGet] parameter #: 1 17:28:53.772 SERIAL « [ACK] (0x06) 17:28:53.773 SERIAL « 0x0104011301e8 (6 bytes) 17:28:53.774 SERIAL » [ACK] (0x06) 17:28:53.775 DRIVER « [RES] [SendData] was sent: true 17:28:53.833 SERIAL « 0x0107001313000007ff (9 bytes) 17:28:53.834 SERIAL » [ACK] (0x06) 17:28:53.835 DRIVER « [REQ] [SendData] callback id: 19 transmit status: OK 17:28:53.921 SERIAL « 0x010b0004002005700601010aa9 (13 bytes) 17:28:53.927 CNTRLR [Node 032] [~] [Configuration] 1: 10 => 10 17:28:53.928 SERIAL » [ACK] (0x06) 17:28:53.930 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 10 17:28:53.932 CNTRLR « [Node 032] parameter #1 has value: 10 17:28:53.932 CNTRLR » [Node 032] querying parameter #2 value... 17:28:53.936 SERIAL » 0x010a00132003700502251483 (12 bytes) 17:28:53.937 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 20 └─[ConfigurationCCGet] parameter #: 2 17:28:53.940 SERIAL « [ACK] (0x06) 17:28:53.947 SERIAL « 0x0104011301e8 (6 bytes) 17:28:53.948 SERIAL » [ACK] (0x06) 17:28:53.950 DRIVER « [RES] [SendData] was sent: true 17:28:54.002 SERIAL « 0x0107001314000006f9 (9 bytes) 17:28:54.002 SERIAL » [ACK] (0x06) 17:28:54.003 DRIVER « [REQ] [SendData] callback id: 20 transmit status: OK 17:28:54.051 SERIAL « 0x010b0004002005700602010faf (13 bytes) 17:28:54.056 CNTRLR [Node 032] [~] [Configuration] 2: 15 => 15 17:28:54.057 SERIAL » [ACK] (0x06) 17:28:54.057 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 15 17:28:54.060 CNTRLR « [Node 032] parameter #2 has value: 15 17:28:54.060 CNTRLR » [Node 032] querying parameter #3 value... 17:28:54.066 SERIAL » 0x010a00132003700503251583 (12 bytes) 17:28:54.066 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 21 └─[ConfigurationCCGet] parameter #: 3 17:28:54.069 SERIAL « 0x010c00040003063105042207bb5c (14 bytes) 17:28:54.072 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:28:54.073 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 105.8 => 197.9 [Endpoint 0] 17:28:54.074 SERIAL » [ACK] (0x06) 17:28:54.074 SERIAL « [CAN] (0x18) 17:28:54.076 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 17:28:54.078 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 197.9 17:28:54.177 SERIAL » 0x010a00132003700503251583 (12 bytes) 17:28:54.177 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 21 └─[ConfigurationCCGet] parameter #: 3 17:28:54.180 SERIAL « [ACK] (0x06) 17:28:54.186 SERIAL « 0x0104011301e8 (6 bytes) 17:28:54.186 SERIAL » [ACK] (0x06) 17:28:54.188 DRIVER « [RES] [SendData] was sent: true 17:28:54.240 SERIAL « 0x0107001315000006f8 (9 bytes) 17:28:54.241 SERIAL » [ACK] (0x06) 17:28:54.242 DRIVER « [REQ] [SendData] callback id: 21 transmit status: OK 17:28:54.290 SERIAL « 0x010b00040020057006030101a0 (13 bytes) 17:28:54.295 CNTRLR [Node 032] [~] [Configuration] 3: 1 => 1 17:28:54.296 SERIAL » [ACK] (0x06) 17:28:54.297 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 1 17:28:54.299 CNTRLR « [Node 032] parameter #3 has value: 1 17:28:54.299 CNTRLR » [Node 032] querying parameter #4 value... 17:28:54.303 SERIAL » 0x010a00132003700504251687 (12 bytes) 17:28:54.303 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 22 └─[ConfigurationCCGet] parameter #: 4 17:28:54.306 SERIAL « [ACK] (0x06) 17:28:54.313 SERIAL « 0x0104011301e8 (6 bytes) 17:28:54.314 SERIAL » [ACK] (0x06) 17:28:54.315 DRIVER « [RES] [SendData] was sent: true 17:28:54.412 SERIAL « 0x010700131600000bf6 (9 bytes) 17:28:54.412 SERIAL » [ACK] (0x06) 17:28:54.413 DRIVER « [REQ] [SendData] callback id: 22 transmit status: OK 17:28:54.462 SERIAL « 0x010b00040020057006040102a4 (13 bytes) 17:28:54.468 CNTRLR [Node 032] [~] [Configuration] 4: 2 => 2 17:28:54.469 SERIAL » [ACK] (0x06) 17:28:54.470 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 1 value: 2 17:28:54.472 CNTRLR « [Node 032] parameter #4 has value: 2 17:28:54.472 CNTRLR » [Node 032] querying parameter #6 value... 17:28:54.478 SERIAL » 0x010a00132003700506251784 (12 bytes) 17:28:54.478 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 23 └─[ConfigurationCCGet] parameter #: 6 17:28:54.480 SERIAL « [ACK] (0x06) 17:28:54.488 SERIAL « 0x0104011301e8 (6 bytes) 17:28:54.488 SERIAL » [ACK] (0x06) 17:28:54.489 DRIVER « [RES] [SendData] was sent: true 17:28:54.581 SERIAL « 0x010700131700000af6 (9 bytes) 17:28:54.581 SERIAL » [ACK] (0x06) 17:28:54.582 DRIVER « [REQ] [SendData] callback id: 23 transmit status: OK 17:28:54.631 SERIAL « 0x010c000400200670060602001ebd (14 bytes) 17:28:54.636 CNTRLR [Node 032] [~] [Configuration] 6: 30 => 30 17:28:54.639 SERIAL » [ACK] (0x06) 17:28:54.647 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 2 value: 30 17:28:54.649 CNTRLR « [Node 032] parameter #6 has value: 30 17:28:54.649 CNTRLR » [Node 032] querying parameter #8 value... 17:28:54.654 SERIAL » 0x010a00132003700508251885 (12 bytes) 17:28:54.654 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 24 └─[ConfigurationCCGet] parameter #: 8 17:28:54.657 SERIAL « [ACK] (0x06) 17:28:54.663 SERIAL « 0x0104011301e8 (6 bytes) 17:28:54.663 SERIAL » [ACK] (0x06) 17:28:54.664 DRIVER « [RES] [SendData] was sent: true 17:28:54.752 SERIAL « 0x010700131800000af9 (9 bytes) 17:28:54.752 SERIAL » [ACK] (0x06) 17:28:54.753 DRIVER « [REQ] [SendData] callback id: 24 transmit status: OK 17:28:54.802 SERIAL « 0x010b00040020057006080100aa (13 bytes) 17:28:54.807 CNTRLR [Node 032] [~] [Configuration] 8: 0 => 0 17:28:54.808 SERIAL » [ACK] (0x06) 17:28:54.809 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 0 17:28:54.811 CNTRLR « [Node 032] parameter #8 has value: 0 17:28:54.811 CNTRLR » [Node 032] querying parameter #9 value... 17:28:54.816 SERIAL » 0x010a00132003700509251985 (12 bytes) 17:28:54.817 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 25 └─[ConfigurationCCGet] parameter #: 9 17:28:54.819 SERIAL « [ACK] (0x06) 17:28:54.825 SERIAL « 0x0104011301e8 (6 bytes) 17:28:54.826 SERIAL » [ACK] (0x06) 17:28:54.826 DRIVER « [RES] [SendData] was sent: true 17:28:54.920 SERIAL « 0x010700131900000af8 (9 bytes) 17:28:54.921 SERIAL » [ACK] (0x06) 17:28:54.922 DRIVER « [REQ] [SendData] callback id: 25 transmit status: OK 17:28:54.932 SERIAL « 0x010c000400030631050422067395 (14 bytes) 17:28:54.940 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:28:54.942 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 197.9 => 165.1 [Endpoint 0] 17:28:54.943 SERIAL » [ACK] (0x06) 17:28:54.946 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 165.1 17:28:54.991 SERIAL « 0x010c000400200670060902002884 (14 bytes) 17:28:54.996 CNTRLR [Node 032] [~] [Configuration] 9: 40 => 40 17:28:54.996 SERIAL » [ACK] (0x06) 17:28:54.997 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 2 value: 40 17:28:54.999 CNTRLR « [Node 032] parameter #9 has value: 40 17:28:54.999 CNTRLR » [Node 032] querying parameter #12 value... 17:28:55.006 SERIAL » 0x010a0013200370050c251a83 (12 bytes) 17:28:55.006 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 26 └─[ConfigurationCCGet] parameter #: 12 17:28:55.009 SERIAL « [ACK] (0x06) 17:28:55.014 SERIAL « 0x0104011301e8 (6 bytes) 17:28:55.015 SERIAL » [ACK] (0x06) 17:28:55.016 DRIVER « [RES] [SendData] was sent: true 17:28:55.112 SERIAL « 0x010700131a00000afb (9 bytes) 17:28:55.112 SERIAL » [ACK] (0x06) 17:28:55.113 DRIVER « [REQ] [SendData] callback id: 26 transmit status: OK 17:28:55.162 SERIAL « 0x010b000400200570060c0100ae (13 bytes) 17:28:55.168 CNTRLR [Node 032] [~] [Configuration] 12: 0 => 0 17:28:55.169 SERIAL » [ACK] (0x06) 17:28:55.170 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 1 value: 0 17:28:55.171 CNTRLR « [Node 032] parameter #12 has value: 0 17:28:55.172 CNTRLR » [Node 032] querying parameter #14 value... 17:28:55.176 SERIAL » 0x010a0013200370050e251b80 (12 bytes) 17:28:55.176 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 27 └─[ConfigurationCCGet] parameter #: 14 17:28:55.179 SERIAL « [ACK] (0x06) 17:28:55.184 SERIAL « 0x0104011301e8 (6 bytes) 17:28:55.185 SERIAL » [ACK] (0x06) 17:28:55.185 DRIVER « [RES] [SendData] was sent: true 17:28:55.281 SERIAL « 0x010700131b00000afa (9 bytes) 17:28:55.282 SERIAL » [ACK] (0x06) 17:28:55.282 DRIVER « [REQ] [SendData] callback id: 27 transmit status: OK 17:28:55.330 SERIAL « 0x010b000400200570060e01ff53 (13 bytes) 17:28:55.335 CNTRLR [Node 032] [~] [Configuration] 14: 255 => 255 17:28:55.336 SERIAL » [ACK] (0x06) 17:28:55.337 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 255 17:28:55.343 CNTRLR « [Node 032] parameter #14 has value: 255 17:28:55.343 CNTRLR » [Node 032] querying parameter #16 value... 17:28:55.347 SERIAL » 0x010a00132003700510251c99 (12 bytes) 17:28:55.348 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 28 └─[ConfigurationCCGet] parameter #: 16 17:28:55.350 SERIAL « [ACK] (0x06) 17:28:55.358 SERIAL « 0x0104011301e8 (6 bytes) 17:28:55.360 SERIAL » [ACK] (0x06) 17:28:55.362 DRIVER « [RES] [SendData] was sent: true 17:28:55.452 SERIAL « 0x010700131c00000afd (9 bytes) 17:28:55.452 SERIAL » [ACK] (0x06) 17:28:55.453 DRIVER « [REQ] [SendData] callback id: 28 transmit status: OK 17:28:55.503 SERIAL « 0x010b00040020057006100100b2 (13 bytes) 17:28:55.508 CNTRLR [Node 032] [~] [Configuration] 16: 0 => 0 17:28:55.509 SERIAL » [ACK] (0x06) 17:28:55.510 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 0 17:28:55.511 CNTRLR « [Node 032] parameter #16 has value: 0 17:28:55.511 CNTRLR » [Node 032] querying parameter #20 value... 17:28:55.515 SERIAL » 0x010a00132003700514251d9c (12 bytes) 17:28:55.516 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 29 └─[ConfigurationCCGet] parameter #: 20 17:28:55.518 SERIAL « [ACK] (0x06) 17:28:55.524 SERIAL « 0x0104011301e8 (6 bytes) 17:28:55.524 SERIAL » [ACK] (0x06) 17:28:55.526 DRIVER « [RES] [SendData] was sent: true 17:28:55.621 SERIAL « 0x010700131d00000afc (9 bytes) 17:28:55.622 SERIAL » [ACK] (0x06) 17:28:55.622 DRIVER « [REQ] [SendData] callback id: 29 transmit status: OK 17:28:55.670 SERIAL « 0x010b0004002005700614010fb9 (13 bytes) 17:28:55.675 CNTRLR [Node 032] [~] [Configuration] 20: 15 => 15 17:28:55.677 SERIAL » [ACK] (0x06) 17:28:55.678 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 15 17:28:55.681 CNTRLR « [Node 032] parameter #20 has value: 15 17:28:55.681 CNTRLR » [Node 032] querying parameter #22 value... 17:28:55.688 SERIAL » 0x010a00132003700516251e9d (12 bytes) 17:28:55.688 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 30 └─[ConfigurationCCGet] parameter #: 22 17:28:55.692 SERIAL « [ACK] (0x06) 17:28:55.699 SERIAL « 0x0104011301e8 (6 bytes) 17:28:55.700 SERIAL » [ACK] (0x06) 17:28:55.703 DRIVER « [RES] [SendData] was sent: true 17:28:55.792 SERIAL « 0x010700131e00000aff (9 bytes) 17:28:55.792 SERIAL » [ACK] (0x06) 17:28:55.793 DRIVER « [REQ] [SendData] callback id: 30 transmit status: OK 17:28:55.843 SERIAL « 0x010c000400200670061602001ead (14 bytes) 17:28:55.850 CNTRLR [Node 032] [~] [Configuration] 22: 30 => 30 17:28:55.851 SERIAL » [ACK] (0x06) 17:28:55.852 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 30 17:28:55.855 CNTRLR « [Node 032] parameter #22 has value: 30 17:28:55.855 CNTRLR » [Node 032] querying parameter #24 value... 17:28:55.866 SERIAL » 0x010a00132003700518251f92 (12 bytes) 17:28:55.866 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 31 └─[ConfigurationCCGet] parameter #: 24 17:28:55.870 SERIAL « [ACK] (0x06) 17:28:55.876 SERIAL « 0x0104011301e8 (6 bytes) 17:28:55.876 SERIAL » [ACK] (0x06) 17:28:55.877 DRIVER « [RES] [SendData] was sent: true 17:28:55.901 SERIAL « 0x010c0004000306310504220817ff (14 bytes) 17:28:55.902 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:28:55.903 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 165.1 => 207.1 [Endpoint 0] 17:28:55.904 SERIAL » [ACK] (0x06) 17:28:55.905 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 207.1 17:28:55.970 SERIAL « 0x010700131f00000afe (9 bytes) 17:28:55.971 SERIAL » [ACK] (0x06) 17:28:55.971 DRIVER « [REQ] [SendData] callback id: 31 transmit status: OK 17:28:56.020 SERIAL « 0x010b00040020057006180100ba (13 bytes) 17:28:56.030 CNTRLR [Node 032] [~] [Configuration] 24: 0 => 0 17:28:56.032 SERIAL » [ACK] (0x06) 17:28:56.033 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 24 value size: 1 value: 0 17:28:56.035 CNTRLR « [Node 032] parameter #24 has value: 0 17:28:56.036 CNTRLR » [Node 032] querying parameter #26 value... 17:28:56.042 SERIAL » 0x010a0013200370051a2520af (12 bytes) 17:28:56.043 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 32 └─[ConfigurationCCGet] parameter #: 26 17:28:56.046 SERIAL « [ACK] (0x06) 17:28:56.052 SERIAL « 0x0104011301e8 (6 bytes) 17:28:56.052 SERIAL » [ACK] (0x06) 17:28:56.054 DRIVER « [RES] [SendData] was sent: true 17:28:56.142 SERIAL « 0x010700132000000ac1 (9 bytes) 17:28:56.142 SERIAL » [ACK] (0x06) 17:28:56.143 DRIVER « [REQ] [SendData] callback id: 32 transmit status: OK 17:28:56.191 SERIAL « 0x010b000400200570061a0100b8 (13 bytes) 17:28:56.203 CNTRLR [Node 032] [~] [Configuration] 26: 0 => 0 17:28:56.205 SERIAL » [ACK] (0x06) 17:28:56.206 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 26 value size: 1 value: 0 17:28:56.209 CNTRLR « [Node 032] parameter #26 has value: 0 17:28:56.210 CNTRLR » [Node 032] querying parameter #40 value... 17:28:56.218 SERIAL » 0x010a0013200370052825219c (12 bytes) 17:28:56.219 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 33 └─[ConfigurationCCGet] parameter #: 40 17:28:56.222 SERIAL « [ACK] (0x06) 17:28:56.227 SERIAL « 0x0104011301e8 (6 bytes) 17:28:56.228 SERIAL » [ACK] (0x06) 17:28:56.229 DRIVER « [RES] [SendData] was sent: true 17:28:56.312 SERIAL « 0x0107001321000009c3 (9 bytes) 17:28:56.312 SERIAL » [ACK] (0x06) 17:28:56.313 DRIVER « [REQ] [SendData] callback id: 33 transmit status: OK 17:28:56.361 SERIAL « 0x010c00040020067006280200c845 (14 bytes) 17:28:56.369 CNTRLR [Node 032] [~] [Configuration] 40: 200 => 200 17:28:56.370 SERIAL » [ACK] (0x06) 17:28:56.372 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 2 value: 200 17:28:56.374 CNTRLR « [Node 032] parameter #40 has value: 200 17:28:56.374 CNTRLR » [Node 032] querying parameter #42 value... 17:28:56.379 SERIAL » 0x010a0013200370052a25229d (12 bytes) 17:28:56.380 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 34 └─[ConfigurationCCGet] parameter #: 42 17:28:56.385 SERIAL « [ACK] (0x06) 17:28:56.392 SERIAL « 0x0104011301e8 (6 bytes) 17:28:56.393 SERIAL » [ACK] (0x06) 17:28:56.394 DRIVER « [RES] [SendData] was sent: true 17:28:56.482 SERIAL « 0x010700132200000ac3 (9 bytes) 17:28:56.483 SERIAL » [ACK] (0x06) 17:28:56.484 DRIVER « [REQ] [SendData] callback id: 34 transmit status: OK 17:28:56.531 SERIAL « 0x010c000400200670062a0200008f (14 bytes) 17:28:56.541 CNTRLR [Node 032] [~] [Configuration] 42: 0 => 0 17:28:56.542 SERIAL » [ACK] (0x06) 17:28:56.544 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 0 17:28:56.546 CNTRLR « [Node 032] parameter #42 has value: 0 17:28:56.547 CNTRLR » [Node 032] querying parameter #60 value... 17:28:56.554 SERIAL » 0x010a0013200370053c25238a (12 bytes) 17:28:56.554 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 35 └─[ConfigurationCCGet] parameter #: 60 17:28:56.558 SERIAL « [ACK] (0x06) 17:28:56.565 SERIAL « 0x0104011301e8 (6 bytes) 17:28:56.565 SERIAL » [ACK] (0x06) 17:28:56.567 DRIVER « [RES] [SendData] was sent: true 17:28:56.652 SERIAL « 0x010700132300000ac2 (9 bytes) 17:28:56.652 SERIAL » [ACK] (0x06) 17:28:56.654 DRIVER « [REQ] [SendData] callback id: 35 transmit status: OK 17:28:56.700 SERIAL « 0x010b000400200570063c010a94 (13 bytes) 17:28:56.712 CNTRLR [Node 032] [~] [Configuration] 60: 10 => 10 17:28:56.714 SERIAL » [ACK] (0x06) 17:28:56.716 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 1 value: 10 17:28:56.719 CNTRLR « [Node 032] parameter #60 has value: 10 17:28:56.719 CNTRLR » [Node 032] querying parameter #62 value... 17:28:56.728 SERIAL » 0x010a0013200370053e25248f (12 bytes) 17:28:56.729 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 36 └─[ConfigurationCCGet] parameter #: 62 17:28:56.734 SERIAL « [ACK] (0x06) 17:28:56.737 SERIAL « 0x0104011301e8 (6 bytes) 17:28:56.739 SERIAL » [ACK] (0x06) 17:28:56.740 DRIVER « [RES] [SendData] was sent: true 17:28:56.822 SERIAL « 0x0107001324000009c6 (9 bytes) 17:28:56.822 SERIAL » [ACK] (0x06) 17:28:56.823 DRIVER « [REQ] [SendData] callback id: 36 transmit status: OK 17:28:56.871 SERIAL « 0x010c000400200670063e0203841c (14 bytes) 17:28:56.876 CNTRLR [Node 032] [~] [Configuration] 62: 900 => 900 17:28:56.877 SERIAL » [ACK] (0x06) 17:28:56.878 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 62 value size: 2 value: 900 17:28:56.881 CNTRLR « [Node 032] parameter #62 has value: 900 17:28:56.881 CNTRLR » [Node 032] querying parameter #64 value... 17:28:56.892 SERIAL » 0x010a001320037005402525f0 (12 bytes) 17:28:56.892 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 37 └─[ConfigurationCCGet] parameter #: 64 17:28:56.895 SERIAL « [ACK] (0x06) 17:28:56.902 SERIAL « 0x0104011301e8 (6 bytes) 17:28:56.903 SERIAL » [ACK] (0x06) 17:28:56.904 DRIVER « [RES] [SendData] was sent: true 17:28:56.907 SERIAL « 0x010c00040003063105042203b152 (14 bytes) 17:28:56.908 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:28:56.909 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 207.1 => 94.5 [Endpoint 0] 17:28:56.910 SERIAL » [ACK] (0x06) 17:28:56.911 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 94.5 17:28:56.952 SERIAL « 0x010c00040003063105042203b152 (14 bytes) 17:28:56.952 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:28:56.953 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 94.5 => 94.5 [Endpoint 0] 17:28:56.954 SERIAL » [ACK] (0x06) 17:28:56.955 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 94.5 17:28:57.019 SERIAL « 0x010700132500000dc3 (9 bytes) 17:28:57.019 SERIAL » [ACK] (0x06) 17:28:57.020 DRIVER « [REQ] [SendData] callback id: 37 transmit status: OK 17:28:57.069 SERIAL « 0x010c0004002006700640020000e5 (14 bytes) 17:28:57.075 CNTRLR [Node 032] [~] [Configuration] 64: 0 => 0 17:28:57.075 SERIAL » [ACK] (0x06) 17:28:57.076 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 64 value size: 2 value: 0 17:28:57.078 CNTRLR « [Node 032] parameter #64 has value: 0 17:28:57.078 CNTRLR » [Node 032] querying parameter #66 value... 17:28:57.082 SERIAL » 0x010a001320037005422526f1 (12 bytes) 17:28:57.082 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 38 └─[ConfigurationCCGet] parameter #: 66 17:28:57.085 SERIAL « [ACK] (0x06) 17:28:57.090 SERIAL « 0x0104011301e8 (6 bytes) 17:28:57.091 SERIAL » [ACK] (0x06) 17:28:57.091 DRIVER « [RES] [SendData] was sent: true 17:28:57.192 SERIAL « 0x010700132600000bc6 (9 bytes) 17:28:57.192 SERIAL » [ACK] (0x06) 17:28:57.193 DRIVER « [REQ] [SendData] callback id: 38 transmit status: OK 17:28:57.241 SERIAL « 0x010c0004002006700642020000e7 (14 bytes) 17:28:57.250 CNTRLR [Node 032] [~] [Configuration] 66: 0 => 0 17:28:57.251 SERIAL » [ACK] (0x06) 17:28:57.252 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 66 value size: 2 value: 0 17:28:57.253 CNTRLR « [Node 032] parameter #66 has value: 0 17:28:57.254 CNTRLR » [Node 032] querying parameter #80 value... 17:28:57.257 SERIAL » 0x010a001320037005502527e2 (12 bytes) 17:28:57.258 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[ConfigurationCCGet] parameter #: 80 17:28:57.262 SERIAL « [ACK] (0x06) 17:28:57.268 SERIAL « 0x0104011301e8 (6 bytes) 17:28:57.268 SERIAL » [ACK] (0x06) 17:28:57.270 DRIVER « [RES] [SendData] was sent: true 17:28:57.361 SERIAL « 0x010700132700000ac6 (9 bytes) 17:28:57.362 SERIAL » [ACK] (0x06) 17:28:57.362 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 17:28:57.410 SERIAL « 0x010b00040020057006500100f2 (13 bytes) 17:28:57.416 CNTRLR [Node 032] [~] [Configuration] 80: 0 => 0 17:28:57.416 SERIAL » [ACK] (0x06) 17:28:57.417 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 80 value size: 1 value: 0 17:28:57.419 CNTRLR « [Node 032] parameter #80 has value: 0 17:28:57.419 CNTRLR » [Node 032] querying parameter #81 value... 17:28:57.423 SERIAL » 0x010a001320037005512528ec (12 bytes) 17:28:57.427 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 40 └─[ConfigurationCCGet] parameter #: 81 17:28:57.429 SERIAL « [ACK] (0x06) 17:28:57.438 SERIAL « 0x0104011301e8 (6 bytes) 17:28:57.438 SERIAL » [ACK] (0x06) 17:28:57.440 DRIVER « [RES] [SendData] was sent: true 17:28:57.532 SERIAL « 0x010700132800000ac9 (9 bytes) 17:28:57.533 SERIAL » [ACK] (0x06) 17:28:57.534 DRIVER « [REQ] [SendData] callback id: 40 transmit status: OK 17:28:57.581 SERIAL « 0x010b00040020057006510132c1 (13 bytes) 17:28:57.591 CNTRLR [Node 032] [~] [Configuration] 81: 50 => 50 17:28:57.593 SERIAL » [ACK] (0x06) 17:28:57.594 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 81 value size: 1 value: 50 17:28:57.597 CNTRLR « [Node 032] parameter #81 has value: 50 17:28:57.597 CNTRLR » [Node 032] querying parameter #82 value... 17:28:57.604 SERIAL » 0x010a001320037005522529ee (12 bytes) 17:28:57.605 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 41 └─[ConfigurationCCGet] parameter #: 82 17:28:57.613 SERIAL « [ACK] (0x06) 17:28:57.617 SERIAL « 0x0104011301e8 (6 bytes) 17:28:57.617 SERIAL » [ACK] (0x06) 17:28:57.618 DRIVER « [RES] [SendData] was sent: true 17:28:57.702 SERIAL « 0x0107001329000009cb (9 bytes) 17:28:57.702 SERIAL » [ACK] (0x06) 17:28:57.703 DRIVER « [REQ] [SendData] callback id: 41 transmit status: OK 17:28:57.751 SERIAL « 0x010c000400200670065202006493 (14 bytes) 17:28:57.761 CNTRLR [Node 032] [~] [Configuration] 82: 100 => 100 17:28:57.763 SERIAL » [ACK] (0x06) 17:28:57.764 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 82 value size: 2 value: 100 17:28:57.767 CNTRLR « [Node 032] parameter #82 has value: 100 17:28:57.767 CNTRLR » [Node 032] querying parameter #83 value... 17:28:57.777 SERIAL » 0x010a00132003700553252aec (12 bytes) 17:28:57.778 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 42 └─[ConfigurationCCGet] parameter #: 83 17:28:57.783 SERIAL « [ACK] (0x06) 17:28:57.788 SERIAL « 0x0104011301e8 (6 bytes) 17:28:57.789 SERIAL » [ACK] (0x06) 17:28:57.793 DRIVER « [RES] [SendData] was sent: true 17:28:57.872 SERIAL « 0x010700132a000009c8 (9 bytes) 17:28:57.872 SERIAL » [ACK] (0x06) 17:28:57.873 DRIVER « [REQ] [SendData] callback id: 42 transmit status: OK 17:28:57.921 SERIAL « 0x010c00040020067006530203e81d (14 bytes) 17:28:57.934 CNTRLR [Node 032] [~] [Configuration] 83: 1000 => 1000 17:28:57.935 SERIAL » [ACK] (0x06) 17:28:57.937 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 83 value size: 2 value: 1000 17:28:57.940 CNTRLR « [Node 032] parameter #83 has value: 1000 17:28:57.941 CNTRLR » [Node 032] querying parameter #86 value... 17:28:57.949 SERIAL » 0x010a00132003700556252be8 (12 bytes) 17:28:57.950 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 43 └─[ConfigurationCCGet] parameter #: 86 17:28:57.953 SERIAL « [ACK] (0x06) 17:28:57.959 SERIAL « 0x0104011301e8 (6 bytes) 17:28:57.960 SERIAL » [ACK] (0x06) 17:28:57.962 DRIVER « [RES] [SendData] was sent: true 17:28:58.042 SERIAL « 0x010700132b000009c9 (9 bytes) 17:28:58.042 SERIAL » [ACK] (0x06) 17:28:58.043 DRIVER « [REQ] [SendData] callback id: 43 transmit status: OK 17:28:58.115 SERIAL « 0x010b00040020057006560112e6 (13 bytes) 17:28:58.122 CNTRLR [Node 032] [~] [Configuration] 86: 18 => 18 17:28:58.123 SERIAL » [ACK] (0x06) 17:28:58.125 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 86 value size: 1 value: 18 17:28:58.127 CNTRLR « [Node 032] parameter #86 has value: 18 17:28:58.128 CNTRLR » [Node 032] querying parameter #87 value... 17:28:58.133 SERIAL » 0x010a00132003700557252cee (12 bytes) 17:28:58.133 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 44 └─[ConfigurationCCGet] parameter #: 87 17:28:58.138 SERIAL « [ACK] (0x06) 17:28:58.144 SERIAL « 0x0104011301e8 (6 bytes) 17:28:58.145 SERIAL » [ACK] (0x06) 17:28:58.146 DRIVER « [RES] [SendData] was sent: true 17:28:58.212 SERIAL « 0x010700132c000008cf (9 bytes) 17:28:58.212 SERIAL » [ACK] (0x06) 17:28:58.214 DRIVER « [REQ] [SendData] callback id: 44 transmit status: OK 17:28:58.261 SERIAL « 0x010b0004002005700657011ce9 (13 bytes) 17:28:58.268 CNTRLR [Node 032] [~] [Configuration] 87: 28 => 28 17:28:58.269 SERIAL » [ACK] (0x06) 17:28:58.271 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 87 value size: 1 value: 28 17:28:58.273 CNTRLR « [Node 032] parameter #87 has value: 28 17:28:58.273 CNTRLR » [Node 032] querying parameter #89 value... 17:28:58.278 SERIAL » 0x010a00132003700559252de1 (12 bytes) 17:28:58.279 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 45 └─[ConfigurationCCGet] parameter #: 89 17:28:58.282 SERIAL « [ACK] (0x06) 17:28:58.289 SERIAL « 0x0104011301e8 (6 bytes) 17:28:58.290 SERIAL » [ACK] (0x06) 17:28:58.291 DRIVER « [RES] [SendData] was sent: true 17:28:58.382 SERIAL « 0x010700132d00000acc (9 bytes) 17:28:58.382 SERIAL » [ACK] (0x06) 17:28:58.383 DRIVER « [REQ] [SendData] callback id: 45 transmit status: OK 17:28:58.431 SERIAL « 0x010b00040020057006590101fa (13 bytes) 17:28:58.443 CNTRLR [Node 032] [~] [Configuration] 89: 1 => 1 17:28:58.444 SERIAL » [ACK] (0x06) 17:28:58.446 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 89 value size: 1 value: 1 17:28:58.449 CNTRLR « [Node 032] parameter #89 has value: 1 17:28:58.450 CNTRLR [Node 032] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:28:58.528 CNTRLR [Node 032] AlarmSensorCC: doing a partial interview... 17:28:58.528 CNTRLR » [Node 032] querying current value for General Purpose... 17:28:58.532 SERIAL » 0x010a001320039c0100252e53 (12 bytes) 17:28:58.533 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 46 └─[AlarmSensorCCGet] sensor type: General Purpose 17:28:58.535 SERIAL « [ACK] (0x06) 17:28:58.541 SERIAL « 0x0104011301e8 (6 bytes) 17:28:58.544 SERIAL » [ACK] (0x06) 17:28:58.545 DRIVER « [RES] [SendData] was sent: true 17:28:58.595 SERIAL « 0x010700132e000006c3 (9 bytes) 17:28:58.596 SERIAL » [ACK] (0x06) 17:28:58.596 DRIVER « [REQ] [SendData] callback id: 46 transmit status: OK 17:28:58.646 SERIAL « 0x010d00040020079c0220000000006f (15 bytes) 17:28:58.647 CNTRLR [Node 032] [~] [Alarm Sensor] state[0]: false => false [Endpoint 0] 17:28:58.648 CNTRLR [Node 032] [+] [Alarm Sensor] severity[0]: undefined [Endpoint 0] 17:28:58.648 CNTRLR [Node 032] [+] [Alarm Sensor] duration[0]: undefined [Endpoint 0] 17:28:58.649 SERIAL » [ACK] (0x06) 17:28:58.650 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: false 17:28:58.652 CNTRLR « [Node 032] received current value for General Purpose: state: false 17:28:58.652 CNTRLR [Node 032] [~] [Alarm Sensor] interviewComplete: true [Endpoint 0] [internal] => true 17:28:58.653 CNTRLR [Node 032] MultiChannelAssociationCC: doing a partial interview... 17:28:58.653 CNTRLR » [Node 032] querying multi channel association group #1... 17:28:58.657 SERIAL » 0x010a001320038e0201252f42 (12 bytes) 17:28:58.658 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 47 └─[MultiChannelAssociationCCGet] group id: 1 17:28:58.660 SERIAL « [ACK] (0x06) 17:28:58.667 SERIAL « 0x0104011301e8 (6 bytes) 17:28:58.667 SERIAL » [ACK] (0x06) 17:28:58.668 DRIVER « [RES] [SendData] was sent: true 17:28:58.772 SERIAL « 0x010700132f00000bcf (9 bytes) 17:28:58.772 SERIAL » [ACK] (0x06) 17:28:58.773 DRIVER « [REQ] [SendData] callback id: 47 transmit status: OK 17:28:58.831 SERIAL « 0x010c00040020068e030105000159 (14 bytes) 17:28:58.831 SERIAL » [ACK] (0x06) 17:28:58.833 CNTRLR [Node 032] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 17:28:58.834 CNTRLR [Node 032] [~] [Multi Channel Association] nodeIds[1]: 1 => 1 17:28:58.835 CNTRLR [Node 032] [~] [Multi Channel Association] endpoints[1]: => 17:28:58.836 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: 1 endpoints: 17:28:58.838 CNTRLR « [Node 032] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 17:28:58.838 CNTRLR » [Node 032] querying multi channel association group #2... 17:28:58.842 SERIAL » 0x010a001320038e020225305e (12 bytes) 17:28:58.843 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 48 └─[MultiChannelAssociationCCGet] group id: 2 17:28:58.845 SERIAL « [ACK] (0x06) 17:28:58.851 SERIAL « 0x0104011301e8 (6 bytes) 17:28:58.852 SERIAL » [ACK] (0x06) 17:28:58.852 DRIVER « [RES] [SendData] was sent: true 17:28:58.942 SERIAL « 0x010700133000000ad1 (9 bytes) 17:28:58.942 SERIAL » [ACK] (0x06) 17:28:58.943 DRIVER « [REQ] [SendData] callback id: 48 transmit status: OK 17:28:58.991 SERIAL « 0x010c00040020068e03020500015a (14 bytes) 17:28:58.991 SERIAL » [ACK] (0x06) 17:28:58.993 CNTRLR [Node 032] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 17:28:58.994 CNTRLR [Node 032] [~] [Multi Channel Association] nodeIds[2]: 1 => 1 17:28:58.995 CNTRLR [Node 032] [~] [Multi Channel Association] endpoints[2]: => 17:28:58.996 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: 1 endpoints: 17:28:58.998 CNTRLR « [Node 032] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 17:28:58.999 CNTRLR » [Node 032] querying additional non-multi-channel association groups... 17:28:58.999 CNTRLR » [Node 032] querying association group #3... 17:28:59.003 SERIAL » 0x010a00132003850203253155 (12 bytes) 17:28:59.004 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 49 └─[AssociationCCGet] group id: 3 17:28:59.005 SERIAL « 0x010c000400030631050422095bb2 (14 bytes) 17:28:59.007 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:28:59.007 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 94.5 => 239.5 [Endpoint 0] 17:28:59.008 SERIAL » [ACK] (0x06) 17:28:59.009 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 239.5 17:28:59.011 SERIAL « [CAN] (0x18) 17:28:59.012 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 17:28:59.113 SERIAL » 0x010a00132003850203253155 (12 bytes) 17:28:59.114 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 49 └─[AssociationCCGet] group id: 3 17:28:59.115 SERIAL « [ACK] (0x06) 17:28:59.122 SERIAL « 0x0104011301e8 (6 bytes) 17:28:59.122 SERIAL » [ACK] (0x06) 17:28:59.123 DRIVER « [RES] [SendData] was sent: true 17:28:59.176 SERIAL « 0x0107001331000006dc (9 bytes) 17:28:59.177 SERIAL » [ACK] (0x06) 17:28:59.177 DRIVER « [REQ] [SendData] callback id: 49 transmit status: OK 17:28:59.228 SERIAL « 0x010c000400200685030301000154 (14 bytes) 17:28:59.229 SERIAL » [ACK] (0x06) 17:28:59.230 CNTRLR [Node 032] [~] [Association] maxNodes[3]: 1 => 1 [internal] 17:28:59.231 CNTRLR [Node 032] [~] [Association] nodeIds[3]: 1 => 1 [internal] 17:28:59.231 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 17:28:59.233 CNTRLR « [Node 032] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 17:28:59.233 CNTRLR [Node 032] [~] [Association] hasLifeline: true => true [internal] 17:28:59.234 CNTRLR [Node 032] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:28:59.301 CNTRLR [Node 032] Interview stage completed: CommandClasses 17:28:59.302 CNTRLR [Node 032] Interview stage completed: OverwriteConfig 17:28:59.302 CNTRLR » [Node 032] requesting node neighbors... 17:28:59.308 SERIAL » 0x010700802000000058 (9 bytes) 17:28:59.309 DRIVER » [Node 032] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:28:59.312 SERIAL « [ACK] (0x06) 17:28:59.315 SERIAL « 0x01200180000000000000000000000000000000000000000000000000000000000 (34 bytes) 05e 17:28:59.316 SERIAL » [ACK] (0x06) 17:28:59.318 DRIVER « [RES] [GetRoutingInfo] node ids: 17:28:59.323 CNTRLR « [Node 032] node neighbors received: 17:28:59.323 CNTRLR [Node 032] Interview stage completed: Neighbors 17:28:59.323 CNTRLR [Node 032] Interview completed 17:29:00.324 CNTRLR » [Node 032] Sending node back to sleep... 17:29:00.333 SERIAL » 0x010900132002840825325c (11 bytes) 17:29:00.334 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 50 └─[WakeUpCCNoMoreInformation] 17:29:00.337 SERIAL « [ACK] (0x06) 17:29:00.343 SERIAL « 0x0104011301e8 (6 bytes) 17:29:00.343 SERIAL » [ACK] (0x06) 17:29:00.345 DRIVER « [RES] [SendData] was sent: true 17:29:00.396 SERIAL « 0x0107001332000006df (9 bytes) 17:29:00.399 SERIAL » [ACK] (0x06) 17:29:00.401 DRIVER « [REQ] [SendData] callback id: 50 transmit status: OK 17:29:00.406 CNTRLR [Node 032] The node is now asleep. 17:29:21.906 SERIAL « 0x010c00040003063105042204cf2b (14 bytes) 17:29:21.909 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:29:21.910 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 239.5 => 123.1 [Endpoint 0] 17:29:21.912 SERIAL » [ACK] (0x06) 17:29:21.915 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 123.1 17:29:26.906 SERIAL « 0x010c00040003063105042208fc14 (14 bytes) 17:29:26.907 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:29:26.908 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 123.1 => 230 [Endpoint 0] 17:29:26.909 SERIAL » [ACK] (0x06) 17:29:26.913 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 230 17:29:27.906 SERIAL « 0x010c00040003063105042203e407 (14 bytes) 17:29:27.907 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:29:27.908 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 230 => 99.6 [Endpoint 0] 17:29:27.908 SERIAL » [ACK] (0x06) 17:29:27.912 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 99.6 17:29:28.906 SERIAL « 0x010c00040003063105042208fd15 (14 bytes) 17:29:28.907 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:29:28.908 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 99.6 => 230.1 [Endpoint 0] 17:29:28.909 SERIAL » [ACK] (0x06) 17:29:28.911 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 230.1 17:29:29.907 SERIAL « 0x010c0004000306310504220719fe (14 bytes) 17:29:29.908 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:29:29.910 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 230.1 => 181.7 [Endpoint 0] 17:29:29.911 SERIAL » [ACK] (0x06) 17:29:29.914 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 181.7 17:29:52.909 SERIAL « 0x010c000400030631050422088d65 (14 bytes) 17:29:52.910 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:29:52.912 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 181.7 => 218.9 [Endpoint 0] 17:29:52.912 SERIAL » [ACK] (0x06) 17:29:52.914 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 218.9 17:29:53.909 SERIAL « 0x010c000400030631050422070fe8 (14 bytes) 17:29:53.911 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:29:53.912 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 218.9 => 180.7 [Endpoint 0] 17:29:53.913 SERIAL » [ACK] (0x06) 17:29:53.915 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 180.7 17:29:54.909 SERIAL « 0x010c00040003063105042204c622 (14 bytes) 17:29:54.910 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:29:54.911 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 180.7 => 122.2 [Endpoint 0] 17:29:54.911 SERIAL » [ACK] (0x06) 17:29:54.913 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 122.2 17:29:55.909 SERIAL « 0x010c0004000306310504220901e8 (14 bytes) 17:29:55.910 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:29:55.910 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 122.2 => 230.5 [Endpoint 0] 17:29:55.913 SERIAL » [ACK] (0x06) 17:29:55.914 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 230.5 17:29:56.910 SERIAL « 0x010c0004000306310504220439dd (14 bytes) 17:29:56.911 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:29:56.912 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 230.5 => 108.1 [Endpoint 0] 17:29:56.913 SERIAL » [ACK] (0x06) 17:29:56.915 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 108.1 17:29:58.909 SERIAL « 0x010c00040003063105042209ac45 (14 bytes) 17:29:58.911 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:29:58.912 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 108.1 => 247.6 [Endpoint 0] 17:29:58.913 SERIAL » [ACK] (0x06) 17:29:58.917 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 247.6 17:30:23.912 SERIAL « 0x010c0004000306310504220502e7 (14 bytes) 17:30:23.914 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:30:23.915 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 247.6 => 128.2 [Endpoint 0] 17:30:23.916 SERIAL » [ACK] (0x06) 17:30:23.918 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 128.2 17:30:24.912 SERIAL « 0x010c00040003063105042208d53d (14 bytes) 17:30:24.913 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:30:24.913 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 128.2 => 226.1 [Endpoint 0] 17:30:24.914 SERIAL » [ACK] (0x06) 17:30:24.915 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 226.1 17:30:26.913 SERIAL « 0x010c000400030631050422059a7f (14 bytes) 17:30:26.915 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:30:26.917 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 226.1 => 143.4 [Endpoint 0] 17:30:26.918 SERIAL » [ACK] (0x06) 17:30:26.929 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 143.4 17:30:27.913 SERIAL « 0x010c000400030631050422036c8f (14 bytes) 17:30:27.913 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:30:27.914 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 143.4 => 87.6 [Endpoint 0] 17:30:27.915 SERIAL » [ACK] (0x06) 17:30:27.916 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 87.6 17:30:28.913 SERIAL « 0x010c0004000306310504220706e1 (14 bytes) 17:30:28.914 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:30:28.915 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 87.6 => 179.8 [Endpoint 0] 17:30:28.916 SERIAL » [ACK] (0x06) 17:30:28.919 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 179.8 17:30:29.222 SERIAL « 0x0108000400060298402f (10 bytes) 17:30:29.223 SERIAL » [ACK] (0x06) 17:30:29.225 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:30:29.240 SERIAL » 0x01110013060a98806ed270b1d99a43ba053318 (19 bytes) 17:30:29.242 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 51 └─[SecurityCCNonceReport] nonce: 0x6ed270b1d99a43ba 17:30:29.245 SERIAL « [ACK] (0x06) 17:30:29.250 SERIAL « 0x0104011301e8 (6 bytes) 17:30:29.251 SERIAL » [ACK] (0x06) 17:30:29.252 DRIVER « [RES] [SendData] was sent: true 17:30:29.354 SERIAL « 0x010700133300000bd3 (9 bytes) 17:30:29.355 SERIAL » [ACK] (0x06) 17:30:29.356 DRIVER « [REQ] [SendData] callback id: 51 transmit status: OK 17:30:29.513 SERIAL « 0x0124000400061e98812e7911b44e4a040f157cde3668d8d1f0bcaf556ed9daa5f (38 bytes) f816a061fb0 17:30:29.515 SERIAL » [ACK] (0x06) 17:30:29.518 CNTRLR [Node 006] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 17:30:29.520 CNTRLR [Node 006] [~] [Multilevel Sensor] Air temperature: 19.1 => 18.6 [Endpoint 2] 17:30:29.521 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.6 17:30:29.658 SERIAL « 0x0108000400060298402f (10 bytes) 17:30:29.659 SERIAL » [ACK] (0x06) 17:30:29.660 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 17:30:29.676 SERIAL » 0x01110013060a988075e1ee10881506b0053499 (19 bytes) 17:30:29.677 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 52 └─[SecurityCCNonceReport] nonce: 0x75e1ee10881506b0 17:30:29.679 SERIAL « [ACK] (0x06) 17:30:29.685 SERIAL « 0x0104011301e8 (6 bytes) 17:30:29.686 SERIAL » [ACK] (0x06) 17:30:29.687 DRIVER « [RES] [SendData] was sent: true 17:30:29.792 SERIAL « 0x010700133400000bd4 (9 bytes) 17:30:29.793 SERIAL » [ACK] (0x06) 17:30:29.794 DRIVER « [REQ] [SendData] callback id: 52 transmit status: OK 17:30:29.893 SERIAL « 0x0124000400061e98811616c779df11fcb8da87cd778b139f5b48cee175baa7f74 (38 bytes) f3268d5cda4 17:30:29.894 SERIAL » [ACK] (0x06) 17:30:29.896 CNTRLR [Node 006] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 17:30:29.898 CNTRLR [Node 006] [~] [Multilevel Sensor] Air temperature: 18.6 => 18.6 [Endpoint 2] 17:30:29.899 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.6 17:30:54.915 SERIAL « 0x010c00040003063105042208668e (14 bytes) 17:30:54.917 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:30:54.918 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 179.8 => 215 [Endpoint 0] 17:30:54.919 SERIAL » [ACK] (0x06) 17:30:54.920 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 215 17:30:55.916 SERIAL « 0x010c000400030631050422049571 (14 bytes) 17:30:55.921 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:30:55.922 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 215 => 117.3 [Endpoint 0] 17:30:55.923 SERIAL » [ACK] (0x06) 17:30:55.924 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 117.3 17:31:01.916 SERIAL « 0x010c000400030631050422081cf4 (14 bytes) 17:31:01.917 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:31:01.919 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 117.3 => 207.6 [Endpoint 0] 17:31:01.920 SERIAL » [ACK] (0x06) 17:31:01.922 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 207.6 17:31:02.916 SERIAL « 0x010c000400030631050422039172 (14 bytes) 17:31:02.918 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:31:02.919 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 207.6 => 91.3 [Endpoint 0] 17:31:02.920 SERIAL » [ACK] (0x06) 17:31:02.922 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 91.3 17:31:03.916 SERIAL « 0x010c000400030631050422043bdf (14 bytes) 17:31:03.918 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:31:03.919 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 91.3 => 108.3 [Endpoint 0] 17:31:03.920 SERIAL » [ACK] (0x06) 17:31:03.922 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 108.3 17:31:04.916 SERIAL « 0x010c0004000306310504220905ec (14 bytes) 17:31:04.918 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:31:04.919 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 108.3 => 230.9 [Endpoint 0] 17:31:04.920 SERIAL » [ACK] (0x06) 17:31:04.922 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 230.9 17:31:20.423 SERIAL « 0x01090004000803300300ca (11 bytes) 17:31:20.425 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:31:20.426 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:31:20.427 SERIAL » [ACK] (0x06) 17:31:20.429 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:31:20.477 SERIAL « 0x01090004000803200100d8 (11 bytes) 17:31:20.479 SERIAL » [ACK] (0x06) 17:31:20.480 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:31:20.483 CNTRLR [Node 008] treating BasicCC Set as a report 17:31:20.483 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:31:25.921 SERIAL « 0x010c00040003063105042204da3e (14 bytes) 17:31:25.923 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:31:25.924 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 230.9 => 124.2 [Endpoint 0] 17:31:25.926 SERIAL » [ACK] (0x06) 17:31:25.928 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 124.2 17:31:26.919 SERIAL « 0x010c00040003063105042207a740 (14 bytes) 17:31:26.920 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:31:26.921 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 124.2 => 195.9 [Endpoint 0] 17:31:26.922 SERIAL » [ACK] (0x06) 17:31:26.924 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 195.9 17:31:28.919 SERIAL « 0x010c000400030631050422047e9a (14 bytes) 17:31:28.920 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:31:28.922 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 195.9 => 115 [Endpoint 0] 17:31:28.923 SERIAL » [ACK] (0x06) 17:31:28.925 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 115 17:31:29.350 SERIAL « 0x0110000400160a600d02003105012200a02f (18 bytes) 17:31:29.352 CNTRLR [Node 022] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 17:31:29.353 CNTRLR [Node 022] [~] [Multilevel Sensor] Air temperature: 15.8 => 16 [Endpoint 2] 17:31:29.354 SERIAL » [ACK] (0x06) 17:31:29.356 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 16 17:31:41.948 SERIAL « 0x010c000400030631050422052fca (14 bytes) 17:31:41.950 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:31:41.951 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 115 => 132.7 [Endpoint 0] 17:31:41.952 SERIAL » [ACK] (0x06) 17:31:41.954 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 132.7 17:31:49.921 SERIAL « 0x010c00040003063105042209ca23 (14 bytes) 17:31:49.922 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:31:49.923 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 132.7 => 250.6 [Endpoint 0] 17:31:49.924 SERIAL » [ACK] (0x06) 17:31:49.926 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 250.6 17:31:56.921 SERIAL « 0x010c000400030631050422043fdb (14 bytes) 17:31:56.922 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:31:56.923 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 250.6 => 108.7 [Endpoint 0] 17:31:56.924 SERIAL » [ACK] (0x06) 17:31:56.925 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 108.7 17:31:57.922 SERIAL « 0x010c0004000306310504220506e3 (14 bytes) 17:31:57.923 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:31:57.925 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 108.7 => 128.6 [Endpoint 0] 17:31:57.926 SERIAL » [ACK] (0x06) 17:31:57.928 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 128.6 17:31:58.964 SERIAL « 0x010900040008033003ff35 (11 bytes) 17:31:58.966 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:31:58.967 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:31:58.968 SERIAL » [ACK] (0x06) 17:31:58.970 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:31:59.019 SERIAL « 0x010900040008032001ff27 (11 bytes) 17:31:59.019 SERIAL » [ACK] (0x06) 17:31:59.021 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:31:59.023 CNTRLR [Node 008] treating BasicCC Set as a report 17:31:59.023 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:32:07.922 SERIAL « 0x010c00040003063105042208648c (14 bytes) 17:32:07.924 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:32:07.933 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 128.6 => 214.8 [Endpoint 0] 17:32:07.934 SERIAL » [ACK] (0x06) 17:32:07.936 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 214.8 17:32:08.951 SERIAL « 0x010c000400030631050422038c6f (14 bytes) 17:32:08.952 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:32:08.954 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 214.8 => 90.8 [Endpoint 0] 17:32:08.955 SERIAL » [ACK] (0x06) 17:32:08.957 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 90.8 17:32:09.923 SERIAL « 0x010c00040003063105042204d531 (14 bytes) 17:32:09.924 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:32:09.926 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 90.8 => 123.7 [Endpoint 0] 17:32:09.927 SERIAL » [ACK] (0x06) 17:32:09.929 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 123.7 17:32:27.924 SERIAL « 0x010c00040003063105042208b850 (14 bytes) 17:32:27.925 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:32:27.925 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 123.7 => 223.2 [Endpoint 0] 17:32:27.926 SERIAL » [ACK] (0x06) 17:32:27.927 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 223.2 17:32:28.925 SERIAL « 0x010c000400030631050422048e6a (14 bytes) 17:32:28.928 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:32:28.929 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 223.2 => 116.6 [Endpoint 0] 17:32:28.930 SERIAL » [ACK] (0x06) 17:32:28.932 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 116.6 17:32:48.926 SERIAL « 0x010c0004000306310504220911f8 (14 bytes) 17:32:48.927 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:32:48.928 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 116.6 => 232.1 [Endpoint 0] 17:32:48.928 SERIAL » [ACK] (0x06) 17:32:48.929 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 232.1 17:32:49.927 SERIAL « 0x010c00040003063105042203b754 (14 bytes) 17:32:49.928 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:32:49.930 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 232.1 => 95.1 [Endpoint 0] 17:32:49.931 SERIAL » [ACK] (0x06) 17:32:49.933 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 95.1 17:32:50.927 SERIAL « 0x010c0004000306310504220450b4 (14 bytes) 17:32:50.928 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:32:50.929 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 95.1 => 110.4 [Endpoint 0] 17:32:50.929 SERIAL » [ACK] (0x06) 17:32:50.931 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 110.4 17:32:51.927 SERIAL « 0x010c00040003063105042209937a (14 bytes) 17:32:51.928 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:32:51.929 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 110.4 => 245.1 [Endpoint 0] 17:32:51.930 SERIAL » [ACK] (0x06) 17:32:51.932 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 245.1 17:32:58.928 SERIAL « 0x010c00040003063105042204bd59 (14 bytes) 17:32:58.930 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:32:58.931 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 245.1 => 121.3 [Endpoint 0] 17:32:58.932 SERIAL » [ACK] (0x06) 17:32:58.934 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 121.3 17:32:59.929 SERIAL « 0x010c00040003063105042207e304 (14 bytes) 17:32:59.930 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:32:59.931 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 121.3 => 201.9 [Endpoint 0] 17:32:59.932 SERIAL » [ACK] (0x06) 17:32:59.933 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 201.9 17:33:03.928 SERIAL « 0x010c0004000306310504220634d2 (14 bytes) 17:33:03.930 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:33:03.931 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 201.9 => 158.8 [Endpoint 0] 17:33:03.932 SERIAL » [ACK] (0x06) 17:33:03.934 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 158.8 17:33:04.937 SERIAL « 0x010c00040003063105042203d132 (14 bytes) 17:33:04.938 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:33:04.940 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 158.8 => 97.7 [Endpoint 0] 17:33:04.941 SERIAL » [ACK] (0x06) 17:33:04.943 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 97.7 17:33:05.928 SERIAL « 0x010c000400030631050422068264 (14 bytes) 17:33:05.929 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:33:05.930 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 97.7 => 166.6 [Endpoint 0] 17:33:05.931 SERIAL » [ACK] (0x06) 17:33:05.932 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 166.6 17:33:29.931 SERIAL « 0x010c0004000306310504220502e7 (14 bytes) 17:33:29.932 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:33:29.932 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 166.6 => 128.2 [Endpoint 0] 17:33:29.933 SERIAL » [ACK] (0x06) 17:33:29.933 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 128.2 17:33:32.931 SERIAL « 0x010c00040003063105042209a841 (14 bytes) 17:33:32.933 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:33:32.934 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 128.2 => 247.2 [Endpoint 0] 17:33:32.935 SERIAL » [ACK] (0x06) 17:33:32.937 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 247.2 17:33:35.931 SERIAL « 0x010c0004000306310504220815fd (14 bytes) 17:33:35.933 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:33:35.934 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 247.2 => 206.9 [Endpoint 0] 17:33:35.937 SERIAL » [ACK] (0x06) 17:33:35.939 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 206.9 17:33:42.932 SERIAL « 0x010c00040003063105042203e506 (14 bytes) 17:33:42.933 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:33:42.933 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 206.9 => 99.7 [Endpoint 0] 17:33:42.935 SERIAL » [ACK] (0x06) 17:33:42.936 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 99.7 17:33:43.931 SERIAL « 0x010c00040003063105042204ff1b (14 bytes) 17:33:43.932 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:33:43.933 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 99.7 => 127.9 [Endpoint 0] 17:33:43.934 SERIAL » [ACK] (0x06) 17:33:43.936 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 127.9 17:33:51.933 SERIAL « 0x010c00040003063105042209a64f (14 bytes) 17:33:51.934 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:33:51.935 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 127.9 => 247 [Endpoint 0] 17:33:51.936 SERIAL » [ACK] (0x06) 17:33:51.937 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 247 17:34:01.934 SERIAL « 0x010c000400030631050422047a9e (14 bytes) 17:34:01.935 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:34:01.936 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 247 => 114.6 [Endpoint 0] 17:34:01.937 SERIAL » [ACK] (0x06) 17:34:01.938 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 114.6 17:34:02.934 SERIAL « 0x010c0004000306310504220533d6 (14 bytes) 17:34:02.936 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:34:02.937 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 114.6 => 133.1 [Endpoint 0] 17:34:02.938 SERIAL » [ACK] (0x06) 17:34:02.940 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 133.1 17:34:03.934 SERIAL « 0x010c00040003063105042209967f (14 bytes) 17:34:03.936 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:34:03.937 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 133.1 => 245.4 [Endpoint 0] 17:34:03.938 SERIAL » [ACK] (0x06) 17:34:03.940 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 245.4 17:34:04.934 SERIAL « 0x010c000400030631050422049b7f (14 bytes) 17:34:04.936 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:34:04.937 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 245.4 => 117.9 [Endpoint 0] 17:34:04.938 SERIAL » [ACK] (0x06) 17:34:04.940 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 117.9 17:34:06.641 SERIAL « 0x01100004001c0a600d02003105012200b93c (18 bytes) 17:34:06.645 CNTRLR [Node 028] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 17:34:06.647 CNTRLR [Node 028] [~] [Multilevel Sensor] Air temperature: 18.8 => 18.5 [Endpoint 2] 17:34:06.648 SERIAL » [ACK] (0x06) 17:34:06.651 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.5 17:34:07.935 SERIAL « 0x010c0004000306310504220853bb (14 bytes) 17:34:07.936 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:34:07.937 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 117.9 => 213.1 [Endpoint 0] 17:34:07.938 SERIAL » [ACK] (0x06) 17:34:07.940 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 213.1 17:34:09.818 SERIAL « 0x01090004000803300300ca (11 bytes) 17:34:09.820 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:34:09.821 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:34:09.822 SERIAL » [ACK] (0x06) 17:34:09.823 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:34:09.873 SERIAL « 0x01090004000803200100d8 (11 bytes) 17:34:09.874 SERIAL » [ACK] (0x06) 17:34:09.875 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:34:09.878 CNTRLR [Node 008] treating BasicCC Set as a report 17:34:09.879 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:34:29.560 SERIAL « 0x01100004001d0a600d02003105012200ae2a (18 bytes) 17:34:29.562 CNTRLR [Node 029] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 17:34:29.563 CNTRLR [Node 029] [~] [Multilevel Sensor] Air temperature: 17.7 => 17.4 [Endpoint 2] 17:34:29.563 SERIAL » [ACK] (0x06) 17:34:29.565 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 17.4 17:34:31.937 SERIAL « 0x010c00040003063105042204a642 (14 bytes) 17:34:31.938 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:34:31.939 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 213.1 => 119 [Endpoint 0] 17:34:31.940 SERIAL » [ACK] (0x06) 17:34:31.942 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 119 17:34:46.939 SERIAL « 0x010c00040003063105042207b354 (14 bytes) 17:34:46.940 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:34:46.941 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 119 => 197.1 [Endpoint 0] 17:34:46.942 SERIAL » [ACK] (0x06) 17:34:46.944 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 197.1 17:34:47.939 SERIAL « 0x010c00040003063105042203f417 (14 bytes) 17:34:47.940 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:34:47.942 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 197.1 => 101.2 [Endpoint 0] 17:34:47.943 SERIAL » [ACK] (0x06) 17:34:47.947 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 101.2 17:34:48.939 SERIAL « 0x010c00040003063105042204fd19 (14 bytes) 17:34:48.940 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:34:48.942 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 101.2 => 127.7 [Endpoint 0] 17:34:48.943 SERIAL » [ACK] (0x06) 17:34:48.945 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 127.7 17:34:52.939 SERIAL « 0x010c000400030631050422097a93 (14 bytes) 17:34:52.940 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:34:52.941 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 127.7 => 242.6 [Endpoint 0] 17:34:52.941 SERIAL » [ACK] (0x06) 17:34:52.942 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 242.6 17:35:02.940 SERIAL « 0x010c00040003063105042203ae4d (14 bytes) 17:35:02.941 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:35:02.942 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 242.6 => 94.2 [Endpoint 0] 17:35:02.942 SERIAL » [ACK] (0x06) 17:35:02.944 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 94.2 17:35:03.941 SERIAL « 0x010c00040003063105042204ef0b (14 bytes) 17:35:03.942 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:35:03.943 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 94.2 => 126.3 [Endpoint 0] 17:35:03.944 SERIAL » [ACK] (0x06) 17:35:03.946 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 126.3 17:35:08.941 SERIAL « 0x010c000400030631050422097c95 (14 bytes) 17:35:08.941 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:35:08.942 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 126.3 => 242.8 [Endpoint 0] 17:35:08.942 SERIAL » [ACK] (0x06) 17:35:08.943 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 242.8 17:35:10.941 SERIAL « 0x010c000400030631050422078d6a (14 bytes) 17:35:10.942 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:35:10.944 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 242.8 => 193.3 [Endpoint 0] 17:35:10.945 SERIAL » [ACK] (0x06) 17:35:10.947 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 193.3 17:35:11.941 SERIAL « 0x010c00040003063105042204a541 (14 bytes) 17:35:11.943 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:35:11.944 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 193.3 => 118.9 [Endpoint 0] 17:35:11.945 SERIAL » [ACK] (0x06) 17:35:11.947 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 118.9 17:35:21.942 SERIAL « 0x010c000400030631050422097d94 (14 bytes) 17:35:21.943 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:35:21.945 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 118.9 => 242.9 [Endpoint 0] 17:35:21.947 SERIAL » [ACK] (0x06) 17:35:21.949 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 242.9 17:35:28.080 SERIAL « 0x01090004001b033003ff26 (11 bytes) 17:35:28.081 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:35:28.081 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:35:28.082 SERIAL » [ACK] (0x06) 17:35:28.083 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:35:28.134 SERIAL « 0x01090004001b032001ff34 (11 bytes) 17:35:28.135 SERIAL » [ACK] (0x06) 17:35:28.135 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:35:28.136 CNTRLR [Node 027] treating BasicCC Set as a report 17:35:28.137 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:35:28.431 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 17:35:28.433 SERIAL » [ACK] (0x06) 17:35:28.434 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 17:35:28.438 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 17:35:33.943 SERIAL « 0x010c00040003063105042204e004 (14 bytes) 17:35:33.944 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:35:33.944 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 242.9 => 124.8 [Endpoint 0] 17:35:33.945 SERIAL » [ACK] (0x06) 17:35:33.946 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 124.8 17:35:35.943 SERIAL « 0x010c000400030631050422087199 (14 bytes) 17:35:35.945 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:35:35.946 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 124.8 => 216.1 [Endpoint 0] 17:35:35.950 SERIAL » [ACK] (0x06) 17:35:35.952 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 216.1 17:35:36.944 SERIAL « 0x010c00040003063105042204ba5e (14 bytes) 17:35:36.945 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:35:36.946 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 216.1 => 121 [Endpoint 0] 17:35:36.947 SERIAL » [ACK] (0x06) 17:35:36.949 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 121 17:35:38.944 SERIAL « 0x010c00040003063105042206cd2b (14 bytes) 17:35:38.945 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:35:38.946 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 121 => 174.1 [Endpoint 0] 17:35:38.947 SERIAL » [ACK] (0x06) 17:35:38.949 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 174.1 17:35:39.944 SERIAL « 0x010c00040003063105042208a74f (14 bytes) 17:35:39.945 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:35:39.946 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 174.1 => 221.5 [Endpoint 0] 17:35:39.946 SERIAL » [ACK] (0x06) 17:35:39.948 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 221.5 17:36:04.946 SERIAL « 0x010c000400030631050422060cea (14 bytes) 17:36:04.947 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:36:04.951 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 221.5 => 154.8 [Endpoint 0] 17:36:04.951 SERIAL » [ACK] (0x06) 17:36:04.953 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 154.8 17:36:05.946 SERIAL « 0x010c000400030631050422078d6a (14 bytes) 17:36:05.948 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:36:05.948 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 154.8 => 193.3 [Endpoint 0] 17:36:05.949 SERIAL » [ACK] (0x06) 17:36:05.951 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 193.3 17:36:06.947 SERIAL « 0x010c000400030631050422041cf8 (14 bytes) 17:36:06.948 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:36:06.949 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 193.3 => 105.2 [Endpoint 0] 17:36:06.950 SERIAL » [ACK] (0x06) 17:36:06.952 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 105.2 17:36:07.947 SERIAL « 0x010c000400030631050422051ffa (14 bytes) 17:36:07.948 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:36:07.950 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 105.2 => 131.1 [Endpoint 0] 17:36:07.950 SERIAL » [ACK] (0x06) 17:36:07.952 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 131.1 17:36:09.947 SERIAL « 0x010c00040003063105042209947d (14 bytes) 17:36:09.948 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:36:09.950 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 131.1 => 245.2 [Endpoint 0] 17:36:09.951 SERIAL » [ACK] (0x06) 17:36:09.954 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 245.2 17:36:14.245 SERIAL « 0x0112000400180c600d02003202213200000000b1 (20 bytes) 17:36:14.248 CNTRLR [Node 024] [~] [Meter] value[66049]: 0 => 0 [Endpoint 2] 17:36:14.250 CNTRLR [Node 024] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 2] 17:36:14.251 SERIAL » [ACK] (0x06) 17:36:14.253 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 17:36:35.950 SERIAL « 0x010c000400030631050422057b9e (14 bytes) 17:36:35.950 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:36:35.951 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 245.2 => 140.3 [Endpoint 0] 17:36:35.951 SERIAL » [ACK] (0x06) 17:36:35.953 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 140.3 17:36:37.950 SERIAL « 0x010c000400030631050422082fc7 (14 bytes) 17:36:37.951 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:36:37.952 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 140.3 => 209.5 [Endpoint 0] 17:36:37.953 SERIAL » [ACK] (0x06) 17:36:37.955 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 209.5 17:36:39.951 SERIAL « 0x010c00040003063105042203ef0c (14 bytes) 17:36:39.953 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:36:39.955 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 209.5 => 100.7 [Endpoint 0] 17:36:39.957 SERIAL » [ACK] (0x06) 17:36:39.959 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 100.7 17:36:40.950 SERIAL « 0x010c000400030631050422096e87 (14 bytes) 17:36:40.952 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:36:40.953 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 100.7 => 241.4 [Endpoint 0] 17:36:40.954 SERIAL » [ACK] (0x06) 17:36:40.957 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 241.4 17:36:41.950 SERIAL « 0x010c00040003063105042203b85b (14 bytes) 17:36:41.952 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:36:41.953 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 241.4 => 95.2 [Endpoint 0] 17:36:41.954 SERIAL » [ACK] (0x06) 17:36:41.956 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 95.2 17:36:43.950 SERIAL « 0x010c0004000306310504220829c1 (14 bytes) 17:36:43.952 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:36:43.953 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 95.2 => 208.9 [Endpoint 0] 17:36:43.954 SERIAL » [ACK] (0x06) 17:36:43.956 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 208.9 17:36:47.977 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 17:36:47.978 SERIAL » [ACK] (0x06) 17:36:47.987 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  17:36:47.991 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 17:36:51.144 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 17:36:51.145 SERIAL » [ACK] (0x06) 17:36:51.146 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 17:36:51.149 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 17:37:01.834 SERIAL « 0x010900040008033003ff35 (11 bytes) 17:37:01.835 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:37:01.837 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:37:01.838 SERIAL » [ACK] (0x06) 17:37:01.840 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:37:01.888 SERIAL « 0x010900040008032001ff27 (11 bytes) 17:37:01.889 SERIAL » [ACK] (0x06) 17:37:01.891 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:37:01.893 CNTRLR [Node 008] treating BasicCC Set as a report 17:37:01.894 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:37:08.953 SERIAL « 0x010c00040003063105042205ea0f (14 bytes) 17:37:08.953 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:37:08.954 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 208.9 => 151.4 [Endpoint 0] 17:37:08.955 SERIAL » [ACK] (0x06) 17:37:08.956 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 151.4 17:37:09.953 SERIAL « 0x010c00040003063105042206fb1d (14 bytes) 17:37:09.955 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:37:09.956 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 151.4 => 178.7 [Endpoint 0] 17:37:09.957 SERIAL » [ACK] (0x06) 17:37:09.958 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 178.7 17:37:11.953 SERIAL « 0x010c0004000306310504220829c1 (14 bytes) 17:37:11.955 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:37:11.956 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 178.7 => 208.9 [Endpoint 0] 17:37:11.957 SERIAL » [ACK] (0x06) 17:37:11.959 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 208.9 17:37:12.953 SERIAL « 0x010c0004000306310504220633d5 (14 bytes) 17:37:12.954 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:37:12.955 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 208.9 => 158.7 [Endpoint 0] 17:37:12.955 SERIAL » [ACK] (0x06) 17:37:12.956 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 158.7 17:37:14.954 SERIAL « 0x010c00040003063105042203fa19 (14 bytes) 17:37:14.955 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:37:14.956 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 158.7 => 101.8 [Endpoint 0] 17:37:14.957 SERIAL » [ACK] (0x06) 17:37:14.965 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 101.8 17:37:22.543 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 17:37:22.544 SERIAL » [ACK] (0x06) 17:37:22.544 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  17:37:22.546 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 17:37:22.994 SERIAL « 0x01080004001502840767 (10 bytes) 17:37:22.995 SERIAL » [ACK] (0x06) 17:37:22.996 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:37:22.999 CNTRLR « [Node 021] received wakeup notification 17:37:23.000 CNTRLR [Node 021] The node is now awake. 17:37:23.007 SERIAL » 0x0109001315028002253560 (11 bytes) 17:37:23.008 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 53 └─[BatteryCCGet] 17:37:23.011 SERIAL « [ACK] (0x06) 17:37:23.016 SERIAL « 0x0104011301e8 (6 bytes) 17:37:23.017 SERIAL » [ACK] (0x06) 17:37:23.019 DRIVER « [RES] [SendData] was sent: true 17:37:23.082 SERIAL « 0x0107001335000007d9 (9 bytes) 17:37:23.083 SERIAL » [ACK] (0x06) 17:37:23.084 DRIVER « [REQ] [SendData] callback id: 53 transmit status: OK 17:37:23.130 SERIAL « 0x0109000400150380036403 (11 bytes) 17:37:23.131 CNTRLR [Node 021] [~] [Battery] level: 100 => 100 [Endpoint 0] 17:37:23.132 CNTRLR [Node 021] [~] [Battery] isLow: false => false [Endpoint 0] 17:37:23.133 SERIAL » [ACK] (0x06) 17:37:23.134 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 17:37:23.138 CNTRLR « [Node 021] received response for battery information: level: 100 17:37:23.139 CNTRLR [Node 021] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:37:23.191 CNTRLR [Node 021] WakeUpCC: doing a partial interview... 17:37:23.191 CNTRLR » [Node 021] retrieving wakeup interval from the device... 17:37:23.196 SERIAL » 0x0109001315028405253660 (11 bytes) 17:37:23.196 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 54 └─[WakeUpCCIntervalGet] 17:37:23.197 SERIAL « [ACK] (0x06) 17:37:23.204 SERIAL « 0x0104011301e8 (6 bytes) 17:37:23.204 SERIAL » [ACK] (0x06) 17:37:23.205 DRIVER « [RES] [SendData] was sent: true 17:37:23.268 SERIAL « 0x0107001336000007da (9 bytes) 17:37:23.269 SERIAL » [ACK] (0x06) 17:37:23.269 DRIVER « [REQ] [SendData] callback id: 54 transmit status: OK 17:37:23.318 SERIAL « 0x010c0004001506840600038401e0 (14 bytes) 17:37:23.319 CNTRLR [Node 021] [~] [Wake Up] wakeUpInterval: 900 => 900 [Endpoint 0] 17:37:23.320 CNTRLR [Node 021] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 17:37:23.320 SERIAL » [ACK] (0x06) 17:37:23.321 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 900 seconds controller node id: 1 17:37:23.323 CNTRLR « [Node 021] received wakeup configuration: wakeup interval: 900 seconds controller node: 1 17:37:23.323 CNTRLR [Node 021] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:37:23.324 CNTRLR [Node 021] AssociationCC: doing a partial interview... 17:37:23.324 CNTRLR [Node 021] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:37:23.324 CNTRLR [Node 021] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:37:23.325 CNTRLR [Node 021] BasicCC: doing a partial interview... 17:37:23.325 CNTRLR » [Node 021] querying Basic CC state... 17:37:23.329 SERIAL » 0x01090013150220022537c2 (11 bytes) 17:37:23.329 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 55 └─[BasicCCGet] 17:37:23.331 SERIAL « [ACK] (0x06) 17:37:23.337 SERIAL « 0x0104011301e8 (6 bytes) 17:37:23.338 SERIAL » [ACK] (0x06) 17:37:23.338 DRIVER « [RES] [SendData] was sent: true 17:37:23.458 SERIAL « 0x010700133700000dd1 (9 bytes) 17:37:23.463 SERIAL » [ACK] (0x06) 17:37:23.463 DRIVER « [REQ] [SendData] callback id: 55 transmit status: OK 17:37:23.507 SERIAL « 0x01090004001503200300c7 (11 bytes) 17:37:23.508 SERIAL » [ACK] (0x06) 17:37:23.508 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BasicCCReport] current value: 0 17:37:23.510 CNTRLR « [Node 021] received Basic CC state: current value: 0 17:37:23.511 CNTRLR [Node 021] [~] [Basic] interviewComplete: true => true [Endpoint 0] [internal] 17:37:23.511 CNTRLR [Node 021] BinarySensorCC: doing a partial interview... 17:37:23.511 CNTRLR » [Node 021] querying current value... 17:37:23.515 SERIAL » 0x01090013150230022538dd (11 bytes) 17:37:23.516 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 56 └─[BinarySensorCCGet] type: Any 17:37:23.517 SERIAL « [ACK] (0x06) 17:37:23.529 SERIAL « 0x0104011301e8 (6 bytes) 17:37:23.529 SERIAL » [ACK] (0x06) 17:37:23.530 DRIVER « [RES] [SendData] was sent: true 17:37:23.638 SERIAL « 0x010700133800000cdf (9 bytes) 17:37:23.639 SERIAL » [ACK] (0x06) 17:37:23.639 DRIVER « [REQ] [SendData] callback id: 56 transmit status: OK 17:37:23.686 SERIAL « 0x01090004001503300300d7 (11 bytes) 17:37:23.687 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:37:23.687 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:37:23.688 SERIAL » [ACK] (0x06) 17:37:23.689 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:37:23.690 CNTRLR « [Node 021] received current value: false 17:37:23.691 CNTRLR [Node 021] [~] [Binary Sensor] interviewComplete: true [Endpoint 0] [internal] => true 17:37:23.727 CNTRLR [Node 021] MultilevelSensorCC: doing a partial interview... 17:37:23.728 CNTRLR » [Node 021] querying Air temperature sensor reading... 17:37:23.732 SERIAL » 0x010b00131504310401002539de (13 bytes) 17:37:23.732 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 57 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 17:37:23.734 SERIAL « [ACK] (0x06) 17:37:23.740 SERIAL « 0x0104011301e8 (6 bytes) 17:37:23.741 SERIAL » [ACK] (0x06) 17:37:23.741 DRIVER « [RES] [SendData] was sent: true 17:37:23.819 SERIAL « 0x0107001339000009db (9 bytes) 17:37:23.820 SERIAL » [ACK] (0x06) 17:37:23.820 DRIVER « [REQ] [SendData] callback id: 57 transmit status: OK 17:37:23.870 SERIAL « 0x010c000400150631050122009f6c (14 bytes) 17:37:23.871 CNTRLR [Node 021] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 17:37:23.872 CNTRLR [Node 021] [~] [Multilevel Sensor] Air temperature: 15.2 => 15.9 [Endpoint 0] 17:37:23.872 SERIAL » [ACK] (0x06) 17:37:23.873 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 15.9 17:37:23.875 CNTRLR « [Node 021] received current Air temperature sensor reading: 15.9 °C 17:37:23.875 CNTRLR » [Node 021] querying Illuminance sensor reading... 17:37:23.881 SERIAL » 0x010b0013150431040308253ad7 (13 bytes) 17:37:23.882 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 58 └─[MultilevelSensorCCGet] sensor type: Illuminance scale: Lux 17:37:23.884 SERIAL « [ACK] (0x06) 17:37:23.890 SERIAL « 0x0104011301e8 (6 bytes) 17:37:23.890 SERIAL » [ACK] (0x06) 17:37:23.891 DRIVER « [RES] [SendData] was sent: true 17:37:24.010 SERIAL « 0x010700133a00000ddc (9 bytes) 17:37:24.010 SERIAL » [ACK] (0x06) 17:37:24.011 DRIVER « [REQ] [SendData] callback id: 58 transmit status: OK 17:37:24.060 SERIAL « 0x010c00040015063105030a0001d8 (14 bytes) 17:37:24.062 CNTRLR [Node 021] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 17:37:24.063 CNTRLR [Node 021] [~] [Multilevel Sensor] Illuminance: 0 => 1 [Endpoint 0] 17:37:24.064 SERIAL » [ACK] (0x06) 17:37:24.066 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 1 17:37:24.069 CNTRLR « [Node 021] received current Illuminance sensor reading: 1 Lux 17:37:24.070 CNTRLR [Node 021] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 17:37:24.144 CNTRLR [Node 021] ConfigurationCC: Loading configuration parameters from device confi g 17:37:24.154 CNTRLR [Node 021] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:37:24.155 CNTRLR [Node 021] [Configuration] 1: metadata updated 17:37:24.157 CNTRLR [Node 021] [Configuration] 2: metadata updated 17:37:24.158 CNTRLR [Node 021] [Configuration] 3: metadata updated 17:37:24.160 CNTRLR [Node 021] [Configuration] 4: metadata updated 17:37:24.161 CNTRLR [Node 021] [Configuration] 6: metadata updated 17:37:24.162 CNTRLR [Node 021] [Configuration] 8: metadata updated 17:37:24.164 CNTRLR [Node 021] [Configuration] 9: metadata updated 17:37:24.165 CNTRLR [Node 021] [Configuration] 12: metadata updated 17:37:24.167 CNTRLR [Node 021] [Configuration] 14: metadata updated 17:37:24.168 CNTRLR [Node 021] [Configuration] 16: metadata updated 17:37:24.169 CNTRLR [Node 021] [Configuration] 20: metadata updated 17:37:24.171 CNTRLR [Node 021] [Configuration] 22: metadata updated 17:37:24.172 CNTRLR [Node 021] [Configuration] 24: metadata updated 17:37:24.173 CNTRLR [Node 021] [Configuration] 26: metadata updated 17:37:24.175 CNTRLR [Node 021] [Configuration] 40: metadata updated 17:37:24.176 CNTRLR [Node 021] [Configuration] 42: metadata updated 17:37:24.177 CNTRLR [Node 021] [Configuration] 60: metadata updated 17:37:24.178 CNTRLR [Node 021] [Configuration] 62: metadata updated 17:37:24.180 CNTRLR [Node 021] [Configuration] 64: metadata updated 17:37:24.181 CNTRLR [Node 021] [Configuration] 66: metadata updated 17:37:24.182 CNTRLR [Node 021] [Configuration] 80: metadata updated 17:37:24.184 CNTRLR [Node 021] [Configuration] 81: metadata updated 17:37:24.185 CNTRLR [Node 021] [Configuration] 82: metadata updated 17:37:24.186 CNTRLR [Node 021] [Configuration] 83: metadata updated 17:37:24.188 CNTRLR [Node 021] [Configuration] 86: metadata updated 17:37:24.189 CNTRLR [Node 021] [Configuration] 87: metadata updated 17:37:24.190 CNTRLR [Node 021] [Configuration] 89: metadata updated 17:37:24.191 CNTRLR [Node 021] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:37:24.192 CNTRLR » [Node 021] querying parameter #1 value... 17:37:24.198 SERIAL » 0x010a00131503700501253b9a (12 bytes) 17:37:24.198 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 59 └─[ConfigurationCCGet] parameter #: 1 17:37:24.216 SERIAL « [ACK] (0x06) 17:37:24.230 SERIAL « 0x0104011301e8 (6 bytes) 17:37:24.231 SERIAL » [ACK] (0x06) 17:37:24.243 DRIVER « [RES] [SendData] was sent: true 17:37:24.272 SERIAL « 0x010700133b000007d7 (9 bytes) 17:37:24.272 SERIAL » [ACK] (0x06) 17:37:24.274 DRIVER « [REQ] [SendData] callback id: 59 transmit status: OK 17:37:24.316 SERIAL « 0x010b0004001505700601010a9c (13 bytes) 17:37:24.321 CNTRLR [Node 021] [~] [Configuration] 1: 10 => 10 17:37:24.322 SERIAL » [ACK] (0x06) 17:37:24.323 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 10 17:37:24.324 CNTRLR « [Node 021] parameter #1 has value: 10 17:37:24.324 CNTRLR » [Node 021] querying parameter #2 value... 17:37:24.328 SERIAL » 0x010a00131503700502253c9e (12 bytes) 17:37:24.329 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 60 └─[ConfigurationCCGet] parameter #: 2 17:37:24.331 SERIAL « [ACK] (0x06) 17:37:24.337 SERIAL « 0x0104011301e8 (6 bytes) 17:37:24.337 SERIAL » [ACK] (0x06) 17:37:24.337 DRIVER « [RES] [SendData] was sent: true 17:37:24.459 SERIAL « 0x010700133c00000dda (9 bytes) 17:37:24.459 SERIAL » [ACK] (0x06) 17:37:24.460 DRIVER « [REQ] [SendData] callback id: 60 transmit status: OK 17:37:24.507 SERIAL « 0x010b0004001505700602010f9a (13 bytes) 17:37:24.512 CNTRLR [Node 021] [~] [Configuration] 2: 15 => 15 17:37:24.513 SERIAL » [ACK] (0x06) 17:37:24.514 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 15 17:37:24.516 CNTRLR « [Node 021] parameter #2 has value: 15 17:37:24.516 CNTRLR » [Node 021] querying parameter #3 value... 17:37:24.520 SERIAL » 0x010a00131503700503253d9e (12 bytes) 17:37:24.520 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 61 └─[ConfigurationCCGet] parameter #: 3 17:37:24.523 SERIAL « [ACK] (0x06) 17:37:24.529 SERIAL « 0x0104011301e8 (6 bytes) 17:37:24.529 SERIAL » [ACK] (0x06) 17:37:24.530 DRIVER « [RES] [SendData] was sent: true 17:37:24.649 SERIAL « 0x010700133d00000ddb (9 bytes) 17:37:24.649 SERIAL » [ACK] (0x06) 17:37:24.650 DRIVER « [REQ] [SendData] callback id: 61 transmit status: OK 17:37:24.697 SERIAL « 0x010b0004001505700603010195 (13 bytes) 17:37:24.703 CNTRLR [Node 021] [~] [Configuration] 3: 1 => 1 17:37:24.703 SERIAL » [ACK] (0x06) 17:37:24.704 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 1 17:37:24.706 CNTRLR « [Node 021] parameter #3 has value: 1 17:37:24.706 CNTRLR » [Node 021] querying parameter #4 value... 17:37:24.714 SERIAL » 0x010a00131503700504253e9a (12 bytes) 17:37:24.714 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 62 └─[ConfigurationCCGet] parameter #: 4 17:37:24.717 SERIAL « [ACK] (0x06) 17:37:24.722 SERIAL « 0x0104011301e8 (6 bytes) 17:37:24.723 SERIAL » [ACK] (0x06) 17:37:24.724 DRIVER « [RES] [SendData] was sent: true 17:37:24.829 SERIAL « 0x010700133e00000bde (9 bytes) 17:37:24.829 SERIAL » [ACK] (0x06) 17:37:24.830 DRIVER « [REQ] [SendData] callback id: 62 transmit status: OK 17:37:24.877 SERIAL « 0x010b0004001505700604010291 (13 bytes) 17:37:24.882 CNTRLR [Node 021] [~] [Configuration] 4: 2 => 2 17:37:24.884 SERIAL » [ACK] (0x06) 17:37:24.885 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 1 value: 2 17:37:24.888 CNTRLR « [Node 021] parameter #4 has value: 2 17:37:24.889 CNTRLR » [Node 021] querying parameter #6 value... 17:37:24.897 SERIAL » 0x010a00131503700506253f99 (12 bytes) 17:37:24.898 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 63 └─[ConfigurationCCGet] parameter #: 6 17:37:24.901 SERIAL « [ACK] (0x06) 17:37:24.907 SERIAL « 0x0104011301e8 (6 bytes) 17:37:24.907 SERIAL » [ACK] (0x06) 17:37:24.908 DRIVER « [RES] [SendData] was sent: true 17:37:25.009 SERIAL « 0x010700133f00000bdf (9 bytes) 17:37:25.009 SERIAL » [ACK] (0x06) 17:37:25.010 DRIVER « [REQ] [SendData] callback id: 63 transmit status: OK 17:37:25.058 SERIAL « 0x010c000400150670060602001e88 (14 bytes) 17:37:25.066 CNTRLR [Node 021] [~] [Configuration] 6: 30 => 30 17:37:25.067 SERIAL » [ACK] (0x06) 17:37:25.068 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 2 value: 30 17:37:25.070 CNTRLR « [Node 021] parameter #6 has value: 30 17:37:25.070 CNTRLR » [Node 021] querying parameter #8 value... 17:37:25.075 SERIAL » 0x010a001315037005082540e8 (12 bytes) 17:37:25.076 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 64 └─[ConfigurationCCGet] parameter #: 8 17:37:25.079 SERIAL « [ACK] (0x06) 17:37:25.086 SERIAL « 0x0104011301e8 (6 bytes) 17:37:25.086 SERIAL » [ACK] (0x06) 17:37:25.088 DRIVER « [RES] [SendData] was sent: true 17:37:25.189 SERIAL « 0x010700134000000ba0 (9 bytes) 17:37:25.189 SERIAL » [ACK] (0x06) 17:37:25.190 DRIVER « [REQ] [SendData] callback id: 64 transmit status: OK 17:37:25.237 SERIAL « 0x010b000400150570060801009f (13 bytes) 17:37:25.247 CNTRLR [Node 021] [~] [Configuration] 8: 0 => 0 17:37:25.248 SERIAL » [ACK] (0x06) 17:37:25.250 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 0 17:37:25.252 CNTRLR « [Node 021] parameter #8 has value: 0 17:37:25.252 CNTRLR » [Node 021] querying parameter #9 value... 17:37:25.259 SERIAL » 0x010a001315037005092541e8 (12 bytes) 17:37:25.260 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 65 └─[ConfigurationCCGet] parameter #: 9 17:37:25.263 SERIAL « [ACK] (0x06) 17:37:25.272 SERIAL « 0x0104011301e8 (6 bytes) 17:37:25.272 SERIAL » [ACK] (0x06) 17:37:25.274 DRIVER « [RES] [SendData] was sent: true 17:37:25.369 SERIAL « 0x010700134100000ba1 (9 bytes) 17:37:25.369 SERIAL » [ACK] (0x06) 17:37:25.370 DRIVER « [REQ] [SendData] callback id: 65 transmit status: OK 17:37:25.419 SERIAL « 0x010c0004001506700609020028b1 (14 bytes) 17:37:25.431 CNTRLR [Node 021] [~] [Configuration] 9: 40 => 40 17:37:25.432 SERIAL » [ACK] (0x06) 17:37:25.433 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 2 value: 40 17:37:25.436 CNTRLR « [Node 021] parameter #9 has value: 40 17:37:25.437 CNTRLR » [Node 021] querying parameter #12 value... 17:37:25.445 SERIAL » 0x010a0013150370050c2542ee (12 bytes) 17:37:25.445 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 66 └─[ConfigurationCCGet] parameter #: 12 17:37:25.450 SERIAL « [ACK] (0x06) 17:37:25.455 SERIAL « 0x0104011301e8 (6 bytes) 17:37:25.456 SERIAL » [ACK] (0x06) 17:37:25.462 DRIVER « [RES] [SendData] was sent: true 17:37:25.549 SERIAL « 0x010700134200000aa3 (9 bytes) 17:37:25.549 SERIAL » [ACK] (0x06) 17:37:25.550 DRIVER « [REQ] [SendData] callback id: 66 transmit status: OK 17:37:25.598 SERIAL « 0x010b000400150570060c01009b (13 bytes) 17:37:25.603 CNTRLR [Node 021] [~] [Configuration] 12: 0 => 0 17:37:25.603 SERIAL » [ACK] (0x06) 17:37:25.604 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 1 value: 0 17:37:25.606 CNTRLR « [Node 021] parameter #12 has value: 0 17:37:25.606 CNTRLR » [Node 021] querying parameter #14 value... 17:37:25.615 SERIAL » 0x010a0013150370050e2543ed (12 bytes) 17:37:25.615 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 67 └─[ConfigurationCCGet] parameter #: 14 17:37:25.618 SERIAL « [ACK] (0x06) 17:37:25.624 SERIAL « 0x0104011301e8 (6 bytes) 17:37:25.624 SERIAL » [ACK] (0x06) 17:37:25.625 DRIVER « [RES] [SendData] was sent: true 17:37:25.729 SERIAL « 0x010700134300000ba3 (9 bytes) 17:37:25.729 SERIAL » [ACK] (0x06) 17:37:25.730 DRIVER « [REQ] [SendData] callback id: 67 transmit status: OK 17:37:25.778 SERIAL « 0x010b000400150570060e01ff66 (13 bytes) 17:37:25.783 CNTRLR [Node 021] [~] [Configuration] 14: 255 => 255 17:37:25.784 SERIAL » [ACK] (0x06) 17:37:25.785 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 255 17:37:25.786 CNTRLR « [Node 021] parameter #14 has value: 255 17:37:25.786 CNTRLR » [Node 021] querying parameter #16 value... 17:37:25.790 SERIAL » 0x010a001315037005102544f4 (12 bytes) 17:37:25.790 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 68 └─[ConfigurationCCGet] parameter #: 16 17:37:25.792 SERIAL « [ACK] (0x06) 17:37:25.801 SERIAL « 0x0104011301e8 (6 bytes) 17:37:25.801 SERIAL » [ACK] (0x06) 17:37:25.802 DRIVER « [RES] [SendData] was sent: true 17:37:25.919 SERIAL « 0x010700134400000da2 (9 bytes) 17:37:25.919 SERIAL » [ACK] (0x06) 17:37:25.919 DRIVER « [REQ] [SendData] callback id: 68 transmit status: OK 17:37:25.968 SERIAL « 0x010b0004001505700610010087 (13 bytes) 17:37:25.973 CNTRLR [Node 021] [~] [Configuration] 16: 0 => 0 17:37:25.973 SERIAL » [ACK] (0x06) 17:37:25.974 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 0 17:37:25.976 CNTRLR « [Node 021] parameter #16 has value: 0 17:37:25.976 CNTRLR » [Node 021] querying parameter #20 value... 17:37:25.979 SERIAL » 0x010a001315037005142545f1 (12 bytes) 17:37:25.980 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 69 └─[ConfigurationCCGet] parameter #: 20 17:37:25.982 SERIAL « [ACK] (0x06) 17:37:25.990 SERIAL « 0x0104011301e8 (6 bytes) 17:37:25.991 SERIAL » [ACK] (0x06) 17:37:25.991 DRIVER « [RES] [SendData] was sent: true 17:37:26.109 SERIAL « 0x010700134500000da3 (9 bytes) 17:37:26.109 SERIAL » [ACK] (0x06) 17:37:26.110 DRIVER « [REQ] [SendData] callback id: 69 transmit status: OK 17:37:26.158 SERIAL « 0x010b0004001505700614010f8c (13 bytes) 17:37:26.166 CNTRLR [Node 021] [~] [Configuration] 20: 15 => 15 17:37:26.166 SERIAL » [ACK] (0x06) 17:37:26.167 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 15 17:37:26.168 CNTRLR « [Node 021] parameter #20 has value: 15 17:37:26.169 CNTRLR » [Node 021] querying parameter #22 value... 17:37:26.172 SERIAL » 0x010a001315037005162546f0 (12 bytes) 17:37:26.173 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 70 └─[ConfigurationCCGet] parameter #: 22 17:37:26.175 SERIAL « [ACK] (0x06) 17:37:26.182 SERIAL « 0x0104011301e8 (6 bytes) 17:37:26.182 SERIAL » [ACK] (0x06) 17:37:26.183 DRIVER « [RES] [SendData] was sent: true 17:37:26.289 SERIAL « 0x010700134600000ca1 (9 bytes) 17:37:26.297 SERIAL » [ACK] (0x06) 17:37:26.298 DRIVER « [REQ] [SendData] callback id: 70 transmit status: OK 17:37:26.339 SERIAL « 0x010c000400150670061602001e98 (14 bytes) 17:37:26.348 CNTRLR [Node 021] [~] [Configuration] 22: 30 => 30 17:37:26.350 SERIAL » [ACK] (0x06) 17:37:26.351 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 30 17:37:26.353 CNTRLR « [Node 021] parameter #22 has value: 30 17:37:26.354 CNTRLR » [Node 021] querying parameter #24 value... 17:37:26.360 SERIAL » 0x010a001315037005182547ff (12 bytes) 17:37:26.361 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 71 └─[ConfigurationCCGet] parameter #: 24 17:37:26.364 SERIAL « [ACK] (0x06) 17:37:26.371 SERIAL « 0x0104011301e8 (6 bytes) 17:37:26.372 SERIAL » [ACK] (0x06) 17:37:26.374 DRIVER « [RES] [SendData] was sent: true 17:37:26.469 SERIAL « 0x010700134700000ba7 (9 bytes) 17:37:26.470 SERIAL » [ACK] (0x06) 17:37:26.471 DRIVER « [REQ] [SendData] callback id: 71 transmit status: OK 17:37:26.517 SERIAL « 0x010b000400150570061801008f (13 bytes) 17:37:26.523 CNTRLR [Node 021] [~] [Configuration] 24: 0 => 0 17:37:26.524 SERIAL » [ACK] (0x06) 17:37:26.525 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 24 value size: 1 value: 0 17:37:26.526 CNTRLR « [Node 021] parameter #24 has value: 0 17:37:26.527 CNTRLR » [Node 021] querying parameter #26 value... 17:37:26.532 SERIAL » 0x010a0013150370051a2548f2 (12 bytes) 17:37:26.532 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 72 └─[ConfigurationCCGet] parameter #: 26 17:37:26.542 SERIAL « [ACK] (0x06) 17:37:26.545 SERIAL « 0x0104011301e8 (6 bytes) 17:37:26.546 SERIAL » [ACK] (0x06) 17:37:26.547 DRIVER « [RES] [SendData] was sent: true 17:37:26.659 SERIAL « 0x010700134800000dae (9 bytes) 17:37:26.659 SERIAL » [ACK] (0x06) 17:37:26.660 DRIVER « [REQ] [SendData] callback id: 72 transmit status: OK 17:37:26.708 SERIAL « 0x010b000400150570061a01008d (13 bytes) 17:37:26.713 CNTRLR [Node 021] [~] [Configuration] 26: 0 => 0 17:37:26.714 SERIAL » [ACK] (0x06) 17:37:26.714 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 26 value size: 1 value: 0 17:37:26.716 CNTRLR « [Node 021] parameter #26 has value: 0 17:37:26.716 CNTRLR » [Node 021] querying parameter #40 value... 17:37:26.720 SERIAL » 0x010a001315037005282549c1 (12 bytes) 17:37:26.720 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 73 └─[ConfigurationCCGet] parameter #: 40 17:37:26.722 SERIAL « [ACK] (0x06) 17:37:26.747 SERIAL « 0x0104011301e8 (6 bytes) 17:37:26.747 SERIAL » [ACK] (0x06) 17:37:26.748 DRIVER « [RES] [SendData] was sent: true 17:37:26.849 SERIAL « 0x010700134900000daf (9 bytes) 17:37:26.850 SERIAL » [ACK] (0x06) 17:37:26.850 DRIVER « [REQ] [SendData] callback id: 73 transmit status: OK 17:37:26.899 SERIAL « 0x010c00040015067006280200c870 (14 bytes) 17:37:26.904 CNTRLR [Node 021] [~] [Configuration] 40: 200 => 200 17:37:26.904 SERIAL » [ACK] (0x06) 17:37:26.905 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 2 value: 200 17:37:26.907 CNTRLR « [Node 021] parameter #40 has value: 200 17:37:26.907 CNTRLR » [Node 021] querying parameter #42 value... 17:37:26.910 SERIAL » 0x010a0013150370052a254ac0 (12 bytes) 17:37:26.911 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 74 └─[ConfigurationCCGet] parameter #: 42 17:37:26.913 SERIAL « [ACK] (0x06) 17:37:26.920 SERIAL « 0x0104011301e8 (6 bytes) 17:37:26.920 SERIAL » [ACK] (0x06) 17:37:26.921 DRIVER « [RES] [SendData] was sent: true 17:37:27.039 SERIAL « 0x010700134a00000dac (9 bytes) 17:37:27.039 SERIAL » [ACK] (0x06) 17:37:27.040 DRIVER « [REQ] [SendData] callback id: 74 transmit status: OK 17:37:27.089 SERIAL « 0x010c000400150670062a020000ba (14 bytes) 17:37:27.097 CNTRLR [Node 021] [~] [Configuration] 42: 0 => 0 17:37:27.097 SERIAL » [ACK] (0x06) 17:37:27.098 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 0 17:37:27.099 CNTRLR « [Node 021] parameter #42 has value: 0 17:37:27.100 CNTRLR » [Node 021] querying parameter #60 value... 17:37:27.103 SERIAL » 0x010a0013150370053c254bd7 (12 bytes) 17:37:27.104 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 75 └─[ConfigurationCCGet] parameter #: 60 17:37:27.106 SERIAL « [ACK] (0x06) 17:37:27.113 SERIAL « 0x0104011301e8 (6 bytes) 17:37:27.113 SERIAL » [ACK] (0x06) 17:37:27.114 DRIVER « [RES] [SendData] was sent: true 17:37:27.232 SERIAL « 0x010700134b00000cac (9 bytes) 17:37:27.233 SERIAL » [ACK] (0x06) 17:37:27.235 DRIVER « [REQ] [SendData] callback id: 75 transmit status: OK 17:37:27.278 SERIAL « 0x010b000400150570063c010aa1 (13 bytes) 17:37:27.288 CNTRLR [Node 021] [~] [Configuration] 60: 10 => 10 17:37:27.289 SERIAL » [ACK] (0x06) 17:37:27.290 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 1 value: 10 17:37:27.293 CNTRLR « [Node 021] parameter #60 has value: 10 17:37:27.293 CNTRLR » [Node 021] querying parameter #62 value... 17:37:27.308 SERIAL » 0x010a0013150370053e254cd2 (12 bytes) 17:37:27.309 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 76 └─[ConfigurationCCGet] parameter #: 62 17:37:27.312 SERIAL « [ACK] (0x06) 17:37:27.320 SERIAL « 0x0104011301e8 (6 bytes) 17:37:27.321 SERIAL » [ACK] (0x06) 17:37:27.322 DRIVER « [RES] [SendData] was sent: true 17:37:27.409 SERIAL « 0x010700134c00000aad (9 bytes) 17:37:27.410 SERIAL » [ACK] (0x06) 17:37:27.410 DRIVER « [REQ] [SendData] callback id: 76 transmit status: OK 17:37:27.458 SERIAL « 0x010c000400150670063e02038429 (14 bytes) 17:37:27.465 CNTRLR [Node 021] [~] [Configuration] 62: 900 => 900 17:37:27.467 SERIAL » [ACK] (0x06) 17:37:27.468 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 62 value size: 2 value: 900 17:37:27.471 CNTRLR « [Node 021] parameter #62 has value: 900 17:37:27.471 CNTRLR » [Node 021] querying parameter #64 value... 17:37:27.476 SERIAL » 0x010a00131503700540254dad (12 bytes) 17:37:27.477 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 77 └─[ConfigurationCCGet] parameter #: 64 17:37:27.479 SERIAL « [ACK] (0x06) 17:37:27.485 SERIAL « 0x0104011301e8 (6 bytes) 17:37:27.485 SERIAL » [ACK] (0x06) 17:37:27.491 DRIVER « [RES] [SendData] was sent: true 17:37:27.589 SERIAL « 0x010700134d00000bad (9 bytes) 17:37:27.590 SERIAL » [ACK] (0x06) 17:37:27.590 DRIVER « [REQ] [SendData] callback id: 77 transmit status: OK 17:37:27.638 SERIAL « 0x010c0004001506700640020000d0 (14 bytes) 17:37:27.643 CNTRLR [Node 021] [~] [Configuration] 64: 0 => 0 17:37:27.644 SERIAL » [ACK] (0x06) 17:37:27.645 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 64 value size: 2 value: 0 17:37:27.646 CNTRLR « [Node 021] parameter #64 has value: 0 17:37:27.647 CNTRLR » [Node 021] querying parameter #66 value... 17:37:27.650 SERIAL » 0x010a00131503700542254eac (12 bytes) 17:37:27.651 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 78 └─[ConfigurationCCGet] parameter #: 66 17:37:27.653 SERIAL « [ACK] (0x06) 17:37:27.659 SERIAL « 0x0104011301e8 (6 bytes) 17:37:27.659 SERIAL » [ACK] (0x06) 17:37:27.660 DRIVER « [RES] [SendData] was sent: true 17:37:27.777 SERIAL « 0x010700134e00000da8 (9 bytes) 17:37:27.777 SERIAL » [ACK] (0x06) 17:37:27.778 DRIVER « [REQ] [SendData] callback id: 78 transmit status: OK 17:37:27.829 SERIAL « 0x010c0004001506700642020000d2 (14 bytes) 17:37:27.834 CNTRLR [Node 021] [~] [Configuration] 66: 0 => 0 17:37:27.835 SERIAL » [ACK] (0x06) 17:37:27.835 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 66 value size: 2 value: 0 17:37:27.837 CNTRLR « [Node 021] parameter #66 has value: 0 17:37:27.837 CNTRLR » [Node 021] querying parameter #80 value... 17:37:27.840 SERIAL » 0x010a00131503700550254fbf (12 bytes) 17:37:27.841 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 79 └─[ConfigurationCCGet] parameter #: 80 17:37:27.843 SERIAL « [ACK] (0x06) 17:37:27.849 SERIAL « 0x0104011301e8 (6 bytes) 17:37:27.850 SERIAL » [ACK] (0x06) 17:37:27.850 DRIVER « [RES] [SendData] was sent: true 17:37:27.969 SERIAL « 0x010700134f00000da9 (9 bytes) 17:37:27.969 SERIAL » [ACK] (0x06) 17:37:27.970 DRIVER « [REQ] [SendData] callback id: 79 transmit status: OK 17:37:28.018 SERIAL « 0x010b00040015057006500100c7 (13 bytes) 17:37:28.023 CNTRLR [Node 021] [~] [Configuration] 80: 0 => 0 17:37:28.024 SERIAL » [ACK] (0x06) 17:37:28.025 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 80 value size: 1 value: 0 17:37:28.026 CNTRLR « [Node 021] parameter #80 has value: 0 17:37:28.026 CNTRLR » [Node 021] querying parameter #81 value... 17:37:28.030 SERIAL » 0x010a001315037005512550a1 (12 bytes) 17:37:28.030 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 80 └─[ConfigurationCCGet] parameter #: 81 17:37:28.033 SERIAL « [ACK] (0x06) 17:37:28.039 SERIAL « 0x0104011301e8 (6 bytes) 17:37:28.040 SERIAL » [ACK] (0x06) 17:37:28.041 DRIVER « [RES] [SendData] was sent: true 17:37:28.159 SERIAL « 0x010700135000000db6 (9 bytes) 17:37:28.160 SERIAL » [ACK] (0x06) 17:37:28.161 DRIVER « [REQ] [SendData] callback id: 80 transmit status: OK 17:37:28.208 SERIAL « 0x010b00040015057006510132f4 (13 bytes) 17:37:28.218 CNTRLR [Node 021] [~] [Configuration] 81: 50 => 50 17:37:28.219 SERIAL » [ACK] (0x06) 17:37:28.221 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 81 value size: 1 value: 50 17:37:28.223 CNTRLR « [Node 021] parameter #81 has value: 50 17:37:28.223 CNTRLR » [Node 021] querying parameter #82 value... 17:37:28.230 SERIAL » 0x010a001315037005522551a3 (12 bytes) 17:37:28.231 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 81 └─[ConfigurationCCGet] parameter #: 82 17:37:28.235 SERIAL « [ACK] (0x06) 17:37:28.241 SERIAL « 0x0104011301e8 (6 bytes) 17:37:28.242 SERIAL » [ACK] (0x06) 17:37:28.243 DRIVER « [RES] [SendData] was sent: true 17:37:28.339 SERIAL « 0x010700135100000bb1 (9 bytes) 17:37:28.339 SERIAL » [ACK] (0x06) 17:37:28.340 DRIVER « [REQ] [SendData] callback id: 81 transmit status: OK 17:37:28.389 SERIAL « 0x010c0004001506700652020064a6 (14 bytes) 17:37:28.399 CNTRLR [Node 021] [~] [Configuration] 82: 100 => 100 17:37:28.400 SERIAL » [ACK] (0x06) 17:37:28.401 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 82 value size: 2 value: 100 17:37:28.404 CNTRLR « [Node 021] parameter #82 has value: 100 17:37:28.404 CNTRLR » [Node 021] querying parameter #83 value... 17:37:28.411 SERIAL » 0x010a001315037005532552a1 (12 bytes) 17:37:28.412 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 82 └─[ConfigurationCCGet] parameter #: 83 17:37:28.415 SERIAL « [ACK] (0x06) 17:37:28.423 SERIAL « 0x0104011301e8 (6 bytes) 17:37:28.423 SERIAL » [ACK] (0x06) 17:37:28.425 DRIVER « [RES] [SendData] was sent: true 17:37:28.519 SERIAL « 0x010700135200000bb2 (9 bytes) 17:37:28.519 SERIAL » [ACK] (0x06) 17:37:28.525 DRIVER « [REQ] [SendData] callback id: 82 transmit status: OK 17:37:28.569 SERIAL « 0x010c00040015067006530203e828 (14 bytes) 17:37:28.579 CNTRLR [Node 021] [~] [Configuration] 83: 1000 => 1000 17:37:28.581 SERIAL » [ACK] (0x06) 17:37:28.582 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 83 value size: 2 value: 1000 17:37:28.584 CNTRLR « [Node 021] parameter #83 has value: 1000 17:37:28.585 CNTRLR » [Node 021] querying parameter #86 value... 17:37:28.598 SERIAL » 0x010a001315037005562553a5 (12 bytes) 17:37:28.599 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 83 └─[ConfigurationCCGet] parameter #: 86 17:37:28.602 SERIAL « [ACK] (0x06) 17:37:28.607 SERIAL « 0x0104011301e8 (6 bytes) 17:37:28.608 SERIAL » [ACK] (0x06) 17:37:28.610 DRIVER « [RES] [SendData] was sent: true 17:37:28.709 SERIAL « 0x010700135300000bb3 (9 bytes) 17:37:28.710 SERIAL » [ACK] (0x06) 17:37:28.710 DRIVER « [REQ] [SendData] callback id: 83 transmit status: OK 17:37:28.758 SERIAL « 0x010b00040015057006560112d3 (13 bytes) 17:37:28.770 CNTRLR [Node 021] [~] [Configuration] 86: 18 => 18 17:37:28.772 SERIAL » [ACK] (0x06) 17:37:28.773 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 86 value size: 1 value: 18 17:37:28.776 CNTRLR « [Node 021] parameter #86 has value: 18 17:37:28.776 CNTRLR » [Node 021] querying parameter #87 value... 17:37:28.784 SERIAL » 0x010a001315037005572554a3 (12 bytes) 17:37:28.785 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 84 └─[ConfigurationCCGet] parameter #: 87 17:37:28.789 SERIAL « [ACK] (0x06) 17:37:28.798 SERIAL « 0x0104011301e8 (6 bytes) 17:37:28.799 SERIAL » [ACK] (0x06) 17:37:28.800 DRIVER « [RES] [SendData] was sent: true 17:37:28.889 SERIAL « 0x010700135400000ab5 (9 bytes) 17:37:28.889 SERIAL » [ACK] (0x06) 17:37:28.890 DRIVER « [REQ] [SendData] callback id: 84 transmit status: OK 17:37:28.938 SERIAL « 0x010b0004001505700657011cdc (13 bytes) 17:37:28.945 CNTRLR [Node 021] [~] [Configuration] 87: 28 => 28 17:37:28.946 SERIAL » [ACK] (0x06) 17:37:28.947 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 87 value size: 1 value: 28 17:37:28.949 CNTRLR « [Node 021] parameter #87 has value: 28 17:37:28.949 CNTRLR » [Node 021] querying parameter #89 value... 17:37:28.955 SERIAL » 0x010a001315037005592555ac (12 bytes) 17:37:28.955 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 85 └─[ConfigurationCCGet] parameter #: 89 17:37:28.958 SERIAL « [ACK] (0x06) 17:37:28.965 SERIAL « 0x0104011301e8 (6 bytes) 17:37:28.966 SERIAL » [ACK] (0x06) 17:37:28.967 DRIVER « [RES] [SendData] was sent: true 17:37:29.039 SERIAL « 0x0107001355000008b6 (9 bytes) 17:37:29.039 SERIAL » [ACK] (0x06) 17:37:29.040 DRIVER « [REQ] [SendData] callback id: 85 transmit status: OK 17:37:29.088 SERIAL « 0x010b00040015057006590101cf (13 bytes) 17:37:29.094 CNTRLR [Node 021] [~] [Configuration] 89: 1 => 1 17:37:29.095 SERIAL » [ACK] (0x06) 17:37:29.096 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 89 value size: 1 value: 1 17:37:29.097 CNTRLR « [Node 021] parameter #89 has value: 1 17:37:29.098 CNTRLR [Node 021] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:37:29.133 CNTRLR [Node 021] AlarmSensorCC: doing a partial interview... 17:37:29.134 CNTRLR » [Node 021] querying current value for General Purpose... 17:37:29.138 SERIAL » 0x010a001315039c010025561e (12 bytes) 17:37:29.138 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 86 └─[AlarmSensorCCGet] sensor type: General Purpose 17:37:29.145 SERIAL « [ACK] (0x06) 17:37:29.151 SERIAL « 0x0104011301e8 (6 bytes) 17:37:29.155 SERIAL » [ACK] (0x06) 17:37:29.156 DRIVER « [RES] [SendData] was sent: true 17:37:29.220 SERIAL « 0x0107001356000008b5 (9 bytes) 17:37:29.220 SERIAL » [ACK] (0x06) 17:37:29.221 DRIVER « [REQ] [SendData] callback id: 86 transmit status: OK 17:37:29.270 SERIAL « 0x010d00040015079c0215000000006f (15 bytes) 17:37:29.271 CNTRLR [Node 021] [~] [Alarm Sensor] state[0]: false => false [Endpoint 0] 17:37:29.272 CNTRLR [Node 021] [+] [Alarm Sensor] severity[0]: undefined [Endpoint 0] 17:37:29.273 CNTRLR [Node 021] [+] [Alarm Sensor] duration[0]: undefined [Endpoint 0] 17:37:29.273 SERIAL » [ACK] (0x06) 17:37:29.275 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: false 17:37:29.277 CNTRLR « [Node 021] received current value for General Purpose: state: false 17:37:29.277 CNTRLR [Node 021] [~] [Alarm Sensor] interviewComplete: true [Endpoint 0] [internal] => true 17:37:29.278 CNTRLR [Node 021] MultiChannelAssociationCC: doing a partial interview... 17:37:29.278 CNTRLR » [Node 021] querying multi channel association group #1... 17:37:29.283 SERIAL » 0x010a001315038e020125570f (12 bytes) 17:37:29.283 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 87 └─[MultiChannelAssociationCCGet] group id: 1 17:37:29.285 SERIAL « [ACK] (0x06) 17:37:29.291 SERIAL « 0x0104011301e8 (6 bytes) 17:37:29.292 SERIAL » [ACK] (0x06) 17:37:29.292 DRIVER « [RES] [SendData] was sent: true 17:37:29.409 SERIAL « 0x010700135700000db1 (9 bytes) 17:37:29.409 SERIAL » [ACK] (0x06) 17:37:29.410 DRIVER « [REQ] [SendData] callback id: 87 transmit status: OK 17:37:29.462 SERIAL « 0x010c00040015068e03010500016c (14 bytes) 17:37:29.462 SERIAL » [ACK] (0x06) 17:37:29.486 CNTRLR [Node 021] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 17:37:29.487 CNTRLR [Node 021] [~] [Multi Channel Association] nodeIds[1]: 1 => 1 17:37:29.488 CNTRLR [Node 021] [~] [Multi Channel Association] endpoints[1]: => 17:37:29.489 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: 1 endpoints: 17:37:29.492 CNTRLR « [Node 021] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 17:37:29.492 CNTRLR » [Node 021] querying multi channel association group #2... 17:37:29.499 SERIAL » 0x010a001315038e0202255803 (12 bytes) 17:37:29.499 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 88 └─[MultiChannelAssociationCCGet] group id: 2 17:37:29.502 SERIAL « [ACK] (0x06) 17:37:29.508 SERIAL « 0x0104011301e8 (6 bytes) 17:37:29.509 SERIAL » [ACK] (0x06) 17:37:29.511 DRIVER « [RES] [SendData] was sent: true 17:37:29.599 SERIAL « 0x010700135800000ab9 (9 bytes) 17:37:29.599 SERIAL » [ACK] (0x06) 17:37:29.600 DRIVER « [REQ] [SendData] callback id: 88 transmit status: OK 17:37:29.649 SERIAL « 0x010c00040015068e03020500016f (14 bytes) 17:37:29.650 SERIAL » [ACK] (0x06) 17:37:29.651 CNTRLR [Node 021] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 17:37:29.652 CNTRLR [Node 021] [~] [Multi Channel Association] nodeIds[2]: 1 => 1 17:37:29.653 CNTRLR [Node 021] [~] [Multi Channel Association] endpoints[2]: => 17:37:29.654 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: 1 endpoints: 17:37:29.655 CNTRLR « [Node 021] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 17:37:29.656 CNTRLR » [Node 021] querying additional non-multi-channel association groups... 17:37:29.656 CNTRLR » [Node 021] querying association group #3... 17:37:29.661 SERIAL » 0x010a00131503850203255908 (12 bytes) 17:37:29.661 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 89 └─[AssociationCCGet] group id: 3 17:37:29.663 SERIAL « [ACK] (0x06) 17:37:29.669 SERIAL « 0x0104011301e8 (6 bytes) 17:37:29.670 SERIAL » [ACK] (0x06) 17:37:29.670 DRIVER « [RES] [SendData] was sent: true 17:37:29.789 SERIAL « 0x010700135900000dbf (9 bytes) 17:37:29.789 SERIAL » [ACK] (0x06) 17:37:29.789 DRIVER « [REQ] [SendData] callback id: 89 transmit status: OK 17:37:29.837 SERIAL « 0x010c000400150685030301000161 (14 bytes) 17:37:29.838 SERIAL » [ACK] (0x06) 17:37:29.839 CNTRLR [Node 021] [~] [Association] maxNodes[3]: 1 => 1 [internal] 17:37:29.839 CNTRLR [Node 021] [~] [Association] nodeIds[3]: 1 => 1 [internal] 17:37:29.839 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 17:37:29.841 CNTRLR « [Node 021] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 17:37:29.841 CNTRLR [Node 021] [~] [Association] hasLifeline: true => true [internal] 17:37:29.842 CNTRLR [Node 021] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:37:30.846 CNTRLR [Node 021] Interview stage completed: CommandClasses 17:37:30.847 CNTRLR [Node 021] Interview stage completed: OverwriteConfig 17:37:30.847 CNTRLR » [Node 021] requesting node neighbors... 17:37:30.855 SERIAL » 0x01070080150000006d (9 bytes) 17:37:30.855 DRIVER » [Node 021] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:37:30.858 SERIAL « [ACK] (0x06) 17:37:30.860 SERIAL « 0x0120018005f80c000000000000000000000000000000000000000000000000000 (34 bytes) 0af 17:37:30.861 SERIAL » [ACK] (0x06) 17:37:30.862 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 12, 13, 14, 15, 16, 19, 20 17:37:30.868 CNTRLR « [Node 021] node neighbors received: 1, 3, 12, 13, 14, 15, 16, 19, 20 17:37:30.868 CNTRLR [Node 021] Interview stage completed: Neighbors 17:37:30.868 CNTRLR [Node 021] Interview completed 17:37:31.870 CNTRLR » [Node 021] Sending node back to sleep... 17:37:31.878 SERIAL » 0x0109001315028408255a01 (11 bytes) 17:37:31.879 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 90 └─[WakeUpCCNoMoreInformation] 17:37:31.881 SERIAL « [ACK] (0x06) 17:37:31.887 SERIAL « 0x0104011301e8 (6 bytes) 17:37:31.888 SERIAL » [ACK] (0x06) 17:37:31.889 DRIVER « [RES] [SendData] was sent: true 17:37:31.950 SERIAL « 0x010700135a000007b6 (9 bytes) 17:37:31.951 SERIAL » [ACK] (0x06) 17:37:31.952 DRIVER « [REQ] [SendData] callback id: 90 transmit status: OK 17:37:31.957 CNTRLR [Node 021] The node is now asleep. 17:37:40.956 SERIAL « 0x010c0004000306310504220507e2 (14 bytes) 17:37:40.958 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:37:40.960 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 101.8 => 128.7 [Endpoint 0] 17:37:40.961 SERIAL » [ACK] (0x06) 17:37:40.963 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 128.7 17:37:43.467 SERIAL « 0x01090004001b03300300d9 (11 bytes) 17:37:43.469 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:37:43.470 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:37:43.471 SERIAL » [ACK] (0x06) 17:37:43.473 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:37:43.521 SERIAL « 0x01090004001b03200100cb (11 bytes) 17:37:43.523 SERIAL » [ACK] (0x06) 17:37:43.524 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:37:43.526 CNTRLR [Node 027] treating BasicCC Set as a report 17:37:43.527 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:37:50.957 SERIAL « 0x010c00040003063105042206ad4b (14 bytes) 17:37:50.958 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:37:50.959 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 128.7 => 170.9 [Endpoint 0] 17:37:50.959 SERIAL » [ACK] (0x06) 17:37:50.961 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 170.9 17:37:51.957 SERIAL « 0x010c000400030631050422047094 (14 bytes) 17:37:51.959 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:37:51.960 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 170.9 => 113.6 [Endpoint 0] 17:37:51.961 SERIAL » [ACK] (0x06) 17:37:51.963 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 113.6 17:37:53.958 SERIAL « 0x010c000400030631050422059772 (14 bytes) 17:37:53.959 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:37:53.960 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 113.6 => 143.1 [Endpoint 0] 17:37:53.961 SERIAL » [ACK] (0x06) 17:37:53.964 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 143.1 17:37:54.957 SERIAL « 0x010c0004000306310504220433d7 (14 bytes) 17:37:54.959 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:37:54.960 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 143.1 => 107.5 [Endpoint 0] 17:37:54.962 SERIAL » [ACK] (0x06) 17:37:54.964 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 107.5 17:37:55.958 SERIAL « 0x010c000400030631050422090ee7 (14 bytes) 17:37:55.959 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:37:55.960 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 107.5 => 231.8 [Endpoint 0] 17:37:55.961 SERIAL » [ACK] (0x06) 17:37:55.963 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 231.8 17:38:09.959 SERIAL « 0x010c000400030631050422077196 (14 bytes) 17:38:09.961 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:38:09.962 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 231.8 => 190.5 [Endpoint 0] 17:38:09.963 SERIAL » [ACK] (0x06) 17:38:09.966 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 190.5 17:38:10.959 SERIAL « 0x010c000400030631050422047397 (14 bytes) 17:38:10.960 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:38:10.961 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 190.5 => 113.9 [Endpoint 0] 17:38:10.962 SERIAL » [ACK] (0x06) 17:38:10.963 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 113.9 17:38:11.959 SERIAL « 0x010c0004000306310504220948a1 (14 bytes) 17:38:11.961 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:38:11.962 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 113.9 => 237.6 [Endpoint 0] 17:38:11.963 SERIAL » [ACK] (0x06) 17:38:11.965 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 237.6 17:38:13.959 SERIAL « 0x010c000400030631050422076582 (14 bytes) 17:38:13.960 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:38:13.961 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 237.6 => 189.3 [Endpoint 0] 17:38:13.961 SERIAL » [ACK] (0x06) 17:38:13.963 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 189.3 17:38:14.960 SERIAL « 0x010c00040003063105042203b754 (14 bytes) 17:38:14.960 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:38:14.961 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 189.3 => 95.1 [Endpoint 0] 17:38:14.961 SERIAL » [ACK] (0x06) 17:38:14.963 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 95.1 17:38:37.437 SERIAL « 0x0108000400080284077a (10 bytes) 17:38:37.438 SERIAL » [ACK] (0x06) 17:38:37.438 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:38:37.441 CNTRLR « [Node 008] received wakeup notification 17:38:37.441 CNTRLR [Node 008] The node is now awake. 17:38:37.445 SERIAL » 0x0109001308028002255b13 (11 bytes) 17:38:37.445 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 91 └─[BatteryCCGet] 17:38:37.447 SERIAL « [ACK] (0x06) 17:38:37.456 SERIAL « 0x0104011301e8 (6 bytes) 17:38:37.456 SERIAL » [ACK] (0x06) 17:38:37.457 DRIVER « [RES] [SendData] was sent: true 17:38:37.481 SERIAL « 0x010700135b000003b3 (9 bytes) 17:38:37.481 SERIAL » [ACK] (0x06) 17:38:37.481 DRIVER « [REQ] [SendData] callback id: 91 transmit status: OK 17:38:37.493 SERIAL « 0x010900040008038003641e (11 bytes) 17:38:37.494 CNTRLR [Node 008] [~] [Battery] level: 100 => 100 [Endpoint 0] 17:38:37.495 CNTRLR [Node 008] [~] [Battery] isLow: false => false [Endpoint 0] 17:38:37.495 SERIAL » [ACK] (0x06) 17:38:37.497 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 17:38:37.498 CNTRLR « [Node 008] received response for battery information: level: 100 17:38:37.499 CNTRLR [Node 008] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:38:37.543 CNTRLR [Node 008] WakeUpCC: doing a partial interview... 17:38:37.543 CNTRLR » [Node 008] retrieving wakeup interval from the device... 17:38:37.547 SERIAL » 0x0109001308028405255c17 (11 bytes) 17:38:37.548 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 92 └─[WakeUpCCIntervalGet] 17:38:37.549 SERIAL « [ACK] (0x06) 17:38:37.556 SERIAL « 0x0104011301e8 (6 bytes) 17:38:37.556 SERIAL » [ACK] (0x06) 17:38:37.557 DRIVER « [RES] [SendData] was sent: true 17:38:37.572 SERIAL « 0x010700135c000002b5 (9 bytes) 17:38:37.573 SERIAL » [ACK] (0x06) 17:38:37.573 DRIVER « [REQ] [SendData] callback id: 92 transmit status: OK 17:38:37.584 SERIAL « 0x010c0004000806840600038401fd (14 bytes) 17:38:37.585 CNTRLR [Node 008] [~] [Wake Up] wakeUpInterval: 900 => 900 [Endpoint 0] 17:38:37.586 CNTRLR [Node 008] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 17:38:37.586 SERIAL » [ACK] (0x06) 17:38:37.587 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 900 seconds controller node id: 1 17:38:37.589 CNTRLR « [Node 008] received wakeup configuration: wakeup interval: 900 seconds controller node: 1 17:38:37.589 CNTRLR [Node 008] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:38:37.590 CNTRLR [Node 008] AssociationCC: doing a partial interview... 17:38:37.590 CNTRLR [Node 008] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:38:37.590 CNTRLR [Node 008] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:38:37.591 CNTRLR [Node 008] BasicCC: doing a partial interview... 17:38:37.591 CNTRLR » [Node 008] querying Basic CC state... 17:38:37.597 SERIAL » 0x0109001308022002255db5 (11 bytes) 17:38:37.598 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 93 └─[BasicCCGet] 17:38:37.603 SERIAL « [ACK] (0x06) 17:38:37.606 SERIAL « 0x0104011301e8 (6 bytes) 17:38:37.606 SERIAL » [ACK] (0x06) 17:38:37.606 DRIVER « [RES] [SendData] was sent: true 17:38:37.623 SERIAL « 0x010700135d000002b4 (9 bytes) 17:38:37.623 SERIAL » [ACK] (0x06) 17:38:37.624 DRIVER « [REQ] [SendData] callback id: 93 transmit status: OK 17:38:37.633 SERIAL « 0x010900040008032003ff25 (11 bytes) 17:38:37.634 SERIAL » [ACK] (0x06) 17:38:37.634 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCReport] current value: 99 17:38:37.636 CNTRLR « [Node 008] received Basic CC state: current value: 99 17:38:37.636 CNTRLR [Node 008] [~] [Basic] interviewComplete: true => true [Endpoint 0] [internal] 17:38:37.637 CNTRLR [Node 008] BinarySensorCC: doing a partial interview... 17:38:37.637 CNTRLR » [Node 008] querying current value... 17:38:37.641 SERIAL » 0x0109001308023002255ea6 (11 bytes) 17:38:37.641 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 94 └─[BinarySensorCCGet] type: Any 17:38:37.643 SERIAL « [ACK] (0x06) 17:38:37.649 SERIAL « 0x0104011301e8 (6 bytes) 17:38:37.649 SERIAL » [ACK] (0x06) 17:38:37.650 DRIVER « [RES] [SendData] was sent: true 17:38:37.666 SERIAL « 0x010700135e000002b7 (9 bytes) 17:38:37.666 SERIAL » [ACK] (0x06) 17:38:37.667 DRIVER « [REQ] [SendData] callback id: 94 transmit status: OK 17:38:37.677 SERIAL « 0x010900040008033003ff35 (11 bytes) 17:38:37.677 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:38:37.678 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:38:37.679 SERIAL » [ACK] (0x06) 17:38:37.680 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:38:37.682 CNTRLR « [Node 008] received current value: true 17:38:37.682 CNTRLR [Node 008] [~] [Binary Sensor] interviewComplete: true [Endpoint 0] [internal] => true 17:38:37.682 CNTRLR [Node 008] MultilevelSensorCC: doing a partial interview... 17:38:37.683 CNTRLR » [Node 008] querying Air temperature sensor reading... 17:38:37.687 SERIAL » 0x010b0013080431040100255fa5 (13 bytes) 17:38:37.688 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 95 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 17:38:37.690 SERIAL « [ACK] (0x06) 17:38:37.696 SERIAL « 0x0104011301e8 (6 bytes) 17:38:37.697 SERIAL » [ACK] (0x06) 17:38:37.697 DRIVER « [RES] [SendData] was sent: true 17:38:37.713 SERIAL « 0x010700135f000002b6 (9 bytes) 17:38:37.714 SERIAL » [ACK] (0x06) 17:38:37.714 DRIVER « [REQ] [SendData] callback id: 95 transmit status: OK 17:38:37.725 SERIAL « 0x010c00040008063105012200a846 (14 bytes) 17:38:37.726 CNTRLR [Node 008] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 17:38:37.726 CNTRLR [Node 008] [~] [Multilevel Sensor] Air temperature: 16.2 => 16.8 [Endpoint 0] 17:38:37.727 SERIAL » [ACK] (0x06) 17:38:37.728 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 16.8 17:38:37.733 CNTRLR « [Node 008] received current Air temperature sensor reading: 16.8 °C 17:38:37.733 CNTRLR » [Node 008] querying Illuminance sensor reading... 17:38:37.737 SERIAL » 0x010b0013080431040308256090 (13 bytes) 17:38:37.737 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 96 └─[MultilevelSensorCCGet] sensor type: Illuminance scale: Lux 17:38:37.769 SERIAL « [ACK] (0x06) 17:38:37.775 SERIAL « 0x0104011301e8 (6 bytes) 17:38:37.775 SERIAL » [ACK] (0x06) 17:38:37.777 DRIVER « [RES] [SendData] was sent: true 17:38:37.779 SERIAL « 0x010700136000000289 (9 bytes) 17:38:37.779 SERIAL » [ACK] (0x06) 17:38:37.780 DRIVER « [REQ] [SendData] callback id: 96 transmit status: OK 17:38:37.782 SERIAL « 0x010c00040008063105030a0009cd (14 bytes) 17:38:37.783 CNTRLR [Node 008] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 17:38:37.784 CNTRLR [Node 008] [~] [Multilevel Sensor] Illuminance: 0 => 9 [Endpoint 0] 17:38:37.784 SERIAL » [ACK] (0x06) 17:38:37.785 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 9 17:38:37.786 CNTRLR « [Node 008] received current Illuminance sensor reading: 9 Lux 17:38:37.787 CNTRLR [Node 008] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 17:38:37.787 CNTRLR [Node 008] ConfigurationCC: Loading configuration parameters from device confi g 17:38:37.794 CNTRLR [Node 008] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:38:37.794 CNTRLR [Node 008] [Configuration] 1: metadata updated 17:38:37.796 CNTRLR [Node 008] [Configuration] 2: metadata updated 17:38:37.797 CNTRLR [Node 008] [Configuration] 3: metadata updated 17:38:37.798 CNTRLR [Node 008] [Configuration] 4: metadata updated 17:38:37.799 CNTRLR [Node 008] [Configuration] 6: metadata updated 17:38:37.800 CNTRLR [Node 008] [Configuration] 8: metadata updated 17:38:37.801 CNTRLR [Node 008] [Configuration] 9: metadata updated 17:38:37.802 CNTRLR [Node 008] [Configuration] 12: metadata updated 17:38:37.803 CNTRLR [Node 008] [Configuration] 14: metadata updated 17:38:37.804 CNTRLR [Node 008] [Configuration] 16: metadata updated 17:38:37.805 CNTRLR [Node 008] [Configuration] 20: metadata updated 17:38:37.806 CNTRLR [Node 008] [Configuration] 22: metadata updated 17:38:37.807 CNTRLR [Node 008] [Configuration] 24: metadata updated 17:38:37.811 CNTRLR [Node 008] [Configuration] 26: metadata updated 17:38:37.812 CNTRLR [Node 008] [Configuration] 40: metadata updated 17:38:37.813 CNTRLR [Node 008] [Configuration] 42: metadata updated 17:38:37.814 CNTRLR [Node 008] [Configuration] 60: metadata updated 17:38:37.815 CNTRLR [Node 008] [Configuration] 62: metadata updated 17:38:37.816 CNTRLR [Node 008] [Configuration] 64: metadata updated 17:38:37.817 CNTRLR [Node 008] [Configuration] 66: metadata updated 17:38:37.818 CNTRLR [Node 008] [Configuration] 80: metadata updated 17:38:37.824 CNTRLR [Node 008] [Configuration] 81: metadata updated 17:38:37.825 CNTRLR [Node 008] [Configuration] 82: metadata updated 17:38:37.826 CNTRLR [Node 008] [Configuration] 83: metadata updated 17:38:37.827 CNTRLR [Node 008] [Configuration] 86: metadata updated 17:38:37.828 CNTRLR [Node 008] [Configuration] 87: metadata updated 17:38:37.829 CNTRLR [Node 008] [Configuration] 89: metadata updated 17:38:37.830 CNTRLR [Node 008] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:38:37.830 CNTRLR » [Node 008] querying parameter #1 value... 17:38:37.836 SERIAL » 0x010a001308037005012561dd (12 bytes) 17:38:37.836 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 97 └─[ConfigurationCCGet] parameter #: 1 17:38:37.846 SERIAL « [ACK] (0x06) 17:38:37.848 SERIAL « 0x0104011301e8 (6 bytes) 17:38:37.848 SERIAL » [ACK] (0x06) 17:38:37.866 DRIVER « [RES] [SendData] was sent: true 17:38:37.899 SERIAL « 0x010700136100000288 (9 bytes) 17:38:37.900 SERIAL » [ACK] (0x06) 17:38:37.906 DRIVER « [REQ] [SendData] callback id: 97 transmit status: OK 17:38:37.917 SERIAL « 0x010b0004000805700601010883 (13 bytes) 17:38:37.927 CNTRLR [Node 008] [~] [Configuration] 1: 8 => 8 17:38:37.929 SERIAL » [ACK] (0x06) 17:38:37.934 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 8 17:38:37.936 CNTRLR « [Node 008] parameter #1 has value: 8 17:38:37.937 CNTRLR » [Node 008] querying parameter #2 value... 17:38:37.942 SERIAL » 0x010a001308037005022562dd (12 bytes) 17:38:37.942 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 98 └─[ConfigurationCCGet] parameter #: 2 17:38:37.984 SERIAL « [ACK] (0x06) 17:38:37.985 SERIAL « 0x0104011301e8 (6 bytes) 17:38:37.985 SERIAL » [ACK] (0x06) 17:38:37.989 DRIVER « [RES] [SendData] was sent: true 17:38:37.995 SERIAL « 0x010c000400030631050422089a72 (14 bytes) 17:38:37.996 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:38:37.997 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 95.1 => 220.2 [Endpoint 0] 17:38:37.997 SERIAL » [ACK] (0x06) 17:38:38.000 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 220.2 17:38:38.003 SERIAL « 0x01070013620000048d (9 bytes) 17:38:38.004 SERIAL » [ACK] (0x06) 17:38:38.006 DRIVER « [REQ] [SendData] callback id: 98 transmit status: OK 17:38:38.010 SERIAL « 0x010b0004000805700602010f87 (13 bytes) 17:38:38.018 CNTRLR [Node 008] [~] [Configuration] 2: 15 => 15 17:38:38.019 SERIAL » [ACK] (0x06) 17:38:38.021 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 15 17:38:38.023 CNTRLR « [Node 008] parameter #2 has value: 15 17:38:38.023 CNTRLR » [Node 008] querying parameter #3 value... 17:38:38.027 SERIAL » 0x010a001308037005032563dd (12 bytes) 17:38:38.027 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 99 └─[ConfigurationCCGet] parameter #: 3 17:38:38.031 SERIAL « [ACK] (0x06) 17:38:38.036 SERIAL « 0x0104011301e8 (6 bytes) 17:38:38.037 SERIAL » [ACK] (0x06) 17:38:38.038 DRIVER « [RES] [SendData] was sent: true 17:38:38.052 SERIAL « 0x01070013630000028a (9 bytes) 17:38:38.053 SERIAL » [ACK] (0x06) 17:38:38.053 DRIVER « [REQ] [SendData] callback id: 99 transmit status: OK 17:38:38.065 SERIAL « 0x010b0004000805700603010188 (13 bytes) 17:38:38.072 CNTRLR [Node 008] [~] [Configuration] 3: 1 => 1 17:38:38.073 SERIAL » [ACK] (0x06) 17:38:38.074 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 1 17:38:38.076 CNTRLR « [Node 008] parameter #3 has value: 1 17:38:38.076 CNTRLR » [Node 008] querying parameter #4 value... 17:38:38.080 SERIAL » 0x010a001308037005042564dd (12 bytes) 17:38:38.081 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 100 └─[ConfigurationCCGet] parameter #: 4 17:38:38.085 SERIAL « [ACK] (0x06) 17:38:38.090 SERIAL « 0x0104011301e8 (6 bytes) 17:38:38.090 SERIAL » [ACK] (0x06) 17:38:38.091 DRIVER « [RES] [SendData] was sent: true 17:38:38.106 SERIAL « 0x01070013640000028d (9 bytes) 17:38:38.106 SERIAL » [ACK] (0x06) 17:38:38.107 DRIVER « [REQ] [SendData] callback id: 100 transmit status: OK 17:38:38.117 SERIAL « 0x010b000400080570060401028c (13 bytes) 17:38:38.122 CNTRLR [Node 008] [~] [Configuration] 4: 2 => 2 17:38:38.123 SERIAL » [ACK] (0x06) 17:38:38.124 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 1 value: 2 17:38:38.125 CNTRLR « [Node 008] parameter #4 has value: 2 17:38:38.125 CNTRLR » [Node 008] querying parameter #6 value... 17:38:38.129 SERIAL » 0x010a001308037005062565de (12 bytes) 17:38:38.130 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 101 └─[ConfigurationCCGet] parameter #: 6 17:38:38.132 SERIAL « [ACK] (0x06) 17:38:38.137 SERIAL « 0x0104011301e8 (6 bytes) 17:38:38.138 SERIAL » [ACK] (0x06) 17:38:38.138 DRIVER « [RES] [SendData] was sent: true 17:38:38.155 SERIAL « 0x01070013650000028c (9 bytes) 17:38:38.155 SERIAL » [ACK] (0x06) 17:38:38.155 DRIVER « [REQ] [SendData] callback id: 101 transmit status: OK 17:38:38.166 SERIAL « 0x010c000400080670060602003cb7 (14 bytes) 17:38:38.171 CNTRLR [Node 008] [~] [Configuration] 6: 60 => 60 17:38:38.172 SERIAL » [ACK] (0x06) 17:38:38.172 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 2 value: 60 17:38:38.174 CNTRLR « [Node 008] parameter #6 has value: 60 17:38:38.174 CNTRLR » [Node 008] querying parameter #8 value... 17:38:38.178 SERIAL » 0x010a001308037005082566d3 (12 bytes) 17:38:38.178 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 102 └─[ConfigurationCCGet] parameter #: 8 17:38:38.180 SERIAL « [ACK] (0x06) 17:38:38.187 SERIAL « 0x0104011301e8 (6 bytes) 17:38:38.188 SERIAL » [ACK] (0x06) 17:38:38.188 DRIVER « [RES] [SendData] was sent: true 17:38:38.204 SERIAL « 0x01070013660000028f (9 bytes) 17:38:38.204 SERIAL » [ACK] (0x06) 17:38:38.204 DRIVER « [REQ] [SendData] callback id: 102 transmit status: OK 17:38:38.214 SERIAL « 0x010b0004000805700608010082 (13 bytes) 17:38:38.219 CNTRLR [Node 008] [~] [Configuration] 8: 0 => 0 17:38:38.220 SERIAL » [ACK] (0x06) 17:38:38.221 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 0 17:38:38.222 CNTRLR « [Node 008] parameter #8 has value: 0 17:38:38.222 CNTRLR » [Node 008] querying parameter #9 value... 17:38:38.226 SERIAL » 0x010a001308037005092567d3 (12 bytes) 17:38:38.226 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 103 └─[ConfigurationCCGet] parameter #: 9 17:38:38.228 SERIAL « [ACK] (0x06) 17:38:38.235 SERIAL « 0x0104011301e8 (6 bytes) 17:38:38.235 SERIAL » [ACK] (0x06) 17:38:38.236 DRIVER « [RES] [SendData] was sent: true 17:38:38.252 SERIAL « 0x01070013670000028e (9 bytes) 17:38:38.252 SERIAL » [ACK] (0x06) 17:38:38.253 DRIVER « [REQ] [SendData] callback id: 103 transmit status: OK 17:38:38.262 SERIAL « 0x010c0004000806700609020028ac (14 bytes) 17:38:38.268 CNTRLR [Node 008] [~] [Configuration] 9: 40 => 40 17:38:38.268 SERIAL » [ACK] (0x06) 17:38:38.269 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 2 value: 40 17:38:38.271 CNTRLR « [Node 008] parameter #9 has value: 40 17:38:38.271 CNTRLR » [Node 008] querying parameter #12 value... 17:38:38.275 SERIAL » 0x010a0013080370050c2568d9 (12 bytes) 17:38:38.275 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 104 └─[ConfigurationCCGet] parameter #: 12 17:38:38.277 SERIAL « [ACK] (0x06) 17:38:38.283 SERIAL « 0x0104011301e8 (6 bytes) 17:38:38.284 SERIAL » [ACK] (0x06) 17:38:38.284 DRIVER « [RES] [SendData] was sent: true 17:38:38.300 SERIAL « 0x010700136800000281 (9 bytes) 17:38:38.301 SERIAL » [ACK] (0x06) 17:38:38.301 DRIVER « [REQ] [SendData] callback id: 104 transmit status: OK 17:38:38.311 SERIAL « 0x010b000400080570060c010086 (13 bytes) 17:38:38.316 CNTRLR [Node 008] [~] [Configuration] 12: 0 => 0 17:38:38.317 SERIAL » [ACK] (0x06) 17:38:38.320 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 1 value: 0 17:38:38.322 CNTRLR « [Node 008] parameter #12 has value: 0 17:38:38.322 CNTRLR » [Node 008] querying parameter #14 value... 17:38:38.326 SERIAL » 0x010a0013080370050e2569da (12 bytes) 17:38:38.326 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 105 └─[ConfigurationCCGet] parameter #: 14 17:38:38.331 SERIAL « [ACK] (0x06) 17:38:38.337 SERIAL « 0x0104011301e8 (6 bytes) 17:38:38.338 SERIAL » [ACK] (0x06) 17:38:38.338 DRIVER « [RES] [SendData] was sent: true 17:38:38.351 SERIAL « 0x010700136900000280 (9 bytes) 17:38:38.352 SERIAL » [ACK] (0x06) 17:38:38.352 DRIVER « [REQ] [SendData] callback id: 105 transmit status: OK 17:38:38.362 SERIAL « 0x010b000400080570060e01ff7b (13 bytes) 17:38:38.367 CNTRLR [Node 008] [~] [Configuration] 14: 255 => 255 17:38:38.368 SERIAL » [ACK] (0x06) 17:38:38.369 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 255 17:38:38.370 CNTRLR « [Node 008] parameter #14 has value: 255 17:38:38.370 CNTRLR » [Node 008] querying parameter #16 value... 17:38:38.374 SERIAL » 0x010a00130803700510256ac7 (12 bytes) 17:38:38.374 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 106 └─[ConfigurationCCGet] parameter #: 16 17:38:38.376 SERIAL « [ACK] (0x06) 17:38:38.382 SERIAL « 0x0104011301e8 (6 bytes) 17:38:38.382 SERIAL » [ACK] (0x06) 17:38:38.383 DRIVER « [RES] [SendData] was sent: true 17:38:38.399 SERIAL « 0x010700136a00000283 (9 bytes) 17:38:38.400 SERIAL » [ACK] (0x06) 17:38:38.400 DRIVER « [REQ] [SendData] callback id: 106 transmit status: OK 17:38:38.410 SERIAL « 0x010b000400080570061001009a (13 bytes) 17:38:38.415 CNTRLR [Node 008] [~] [Configuration] 16: 0 => 0 17:38:38.416 SERIAL » [ACK] (0x06) 17:38:38.417 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 0 17:38:38.418 CNTRLR « [Node 008] parameter #16 has value: 0 17:38:38.418 CNTRLR » [Node 008] querying parameter #20 value... 17:38:38.422 SERIAL » 0x010a00130803700514256bc2 (12 bytes) 17:38:38.422 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 107 └─[ConfigurationCCGet] parameter #: 20 17:38:38.425 SERIAL « [ACK] (0x06) 17:38:38.431 SERIAL « 0x0104011301e8 (6 bytes) 17:38:38.432 SERIAL » [ACK] (0x06) 17:38:38.432 DRIVER « [RES] [SendData] was sent: true 17:38:38.448 SERIAL « 0x010700136b00000383 (9 bytes) 17:38:38.448 SERIAL » [ACK] (0x06) 17:38:38.448 DRIVER « [REQ] [SendData] callback id: 107 transmit status: OK 17:38:38.458 SERIAL « 0x010b0004000805700614010f91 (13 bytes) 17:38:38.464 CNTRLR [Node 008] [~] [Configuration] 20: 15 => 15 17:38:38.465 SERIAL » [ACK] (0x06) 17:38:38.466 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 15 17:38:38.467 CNTRLR « [Node 008] parameter #20 has value: 15 17:38:38.467 CNTRLR » [Node 008] querying parameter #22 value... 17:38:38.474 SERIAL » 0x010a00130803700516256cc7 (12 bytes) 17:38:38.475 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 108 └─[ConfigurationCCGet] parameter #: 22 17:38:38.478 SERIAL « [ACK] (0x06) 17:38:38.483 SERIAL « 0x0104011301e8 (6 bytes) 17:38:38.484 SERIAL » [ACK] (0x06) 17:38:38.485 DRIVER « [RES] [SendData] was sent: true 17:38:38.500 SERIAL « 0x010700136c00000285 (9 bytes) 17:38:38.500 SERIAL » [ACK] (0x06) 17:38:38.501 DRIVER « [REQ] [SendData] callback id: 108 transmit status: OK 17:38:38.511 SERIAL « 0x010c000400080670061602001e85 (14 bytes) 17:38:38.516 CNTRLR [Node 008] [~] [Configuration] 22: 30 => 30 17:38:38.517 SERIAL » [ACK] (0x06) 17:38:38.518 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 30 17:38:38.520 CNTRLR « [Node 008] parameter #22 has value: 30 17:38:38.520 CNTRLR » [Node 008] querying parameter #24 value... 17:38:38.524 SERIAL » 0x010a00130803700518256dc8 (12 bytes) 17:38:38.525 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 109 └─[ConfigurationCCGet] parameter #: 24 17:38:38.527 SERIAL « [ACK] (0x06) 17:38:38.535 SERIAL « 0x0104011301e8 (6 bytes) 17:38:38.536 SERIAL » [ACK] (0x06) 17:38:38.538 DRIVER « [RES] [SendData] was sent: true 17:38:38.551 SERIAL « 0x010700136d00000284 (9 bytes) 17:38:38.552 SERIAL » [ACK] (0x06) 17:38:38.552 DRIVER « [REQ] [SendData] callback id: 109 transmit status: OK 17:38:38.562 SERIAL « 0x010b0004000805700618010092 (13 bytes) 17:38:38.567 CNTRLR [Node 008] [~] [Configuration] 24: 0 => 0 17:38:38.568 SERIAL » [ACK] (0x06) 17:38:38.569 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 24 value size: 1 value: 0 17:38:38.572 CNTRLR « [Node 008] parameter #24 has value: 0 17:38:38.573 CNTRLR » [Node 008] querying parameter #26 value... 17:38:38.576 SERIAL » 0x010a0013080370051a256ec9 (12 bytes) 17:38:38.577 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 110 └─[ConfigurationCCGet] parameter #: 26 17:38:38.579 SERIAL « [ACK] (0x06) 17:38:38.585 SERIAL « 0x0104011301e8 (6 bytes) 17:38:38.586 SERIAL » [ACK] (0x06) 17:38:38.587 DRIVER « [RES] [SendData] was sent: true 17:38:38.602 SERIAL « 0x010700136e00000287 (9 bytes) 17:38:38.602 SERIAL » [ACK] (0x06) 17:38:38.603 DRIVER « [REQ] [SendData] callback id: 110 transmit status: OK 17:38:38.613 SERIAL « 0x010b000400080570061a010090 (13 bytes) 17:38:38.618 CNTRLR [Node 008] [~] [Configuration] 26: 0 => 0 17:38:38.619 SERIAL » [ACK] (0x06) 17:38:38.619 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 26 value size: 1 value: 0 17:38:38.621 CNTRLR « [Node 008] parameter #26 has value: 0 17:38:38.621 CNTRLR » [Node 008] querying parameter #40 value... 17:38:38.625 SERIAL » 0x010a00130803700528256ffa (12 bytes) 17:38:38.625 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 111 └─[ConfigurationCCGet] parameter #: 40 17:38:38.627 SERIAL « [ACK] (0x06) 17:38:38.633 SERIAL « 0x0104011301e8 (6 bytes) 17:38:38.634 SERIAL » [ACK] (0x06) 17:38:38.634 DRIVER « [RES] [SendData] was sent: true 17:38:38.650 SERIAL « 0x010700136f00000286 (9 bytes) 17:38:38.651 SERIAL » [ACK] (0x06) 17:38:38.651 DRIVER « [REQ] [SendData] callback id: 111 transmit status: OK 17:38:38.661 SERIAL « 0x010c00040008067006280200c86d (14 bytes) 17:38:38.669 CNTRLR [Node 008] [~] [Configuration] 40: 200 => 200 17:38:38.670 SERIAL » [ACK] (0x06) 17:38:38.671 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 2 value: 200 17:38:38.672 CNTRLR « [Node 008] parameter #40 has value: 200 17:38:38.673 CNTRLR » [Node 008] querying parameter #42 value... 17:38:38.678 SERIAL » 0x010a0013080370052a2570e7 (12 bytes) 17:38:38.678 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 112 └─[ConfigurationCCGet] parameter #: 42 17:38:38.681 SERIAL « [ACK] (0x06) 17:38:38.686 SERIAL « 0x0104011301e8 (6 bytes) 17:38:38.687 SERIAL » [ACK] (0x06) 17:38:38.688 DRIVER « [RES] [SendData] was sent: true 17:38:38.709 SERIAL « 0x010700137000000299 (9 bytes) 17:38:38.710 SERIAL » [ACK] (0x06) 17:38:38.710 DRIVER « [REQ] [SendData] callback id: 112 transmit status: OK 17:38:38.718 SERIAL « 0x010c000400080670062a020000a7 (14 bytes) 17:38:38.726 CNTRLR [Node 008] [~] [Configuration] 42: 0 => 0 17:38:38.727 SERIAL » [ACK] (0x06) 17:38:38.728 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 0 17:38:38.730 CNTRLR « [Node 008] parameter #42 has value: 0 17:38:38.730 CNTRLR » [Node 008] querying parameter #60 value... 17:38:38.736 SERIAL » 0x010a0013080370053c2571f0 (12 bytes) 17:38:38.736 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 113 └─[ConfigurationCCGet] parameter #: 60 17:38:38.739 SERIAL « [ACK] (0x06) 17:38:38.745 SERIAL « 0x0104011301e8 (6 bytes) 17:38:38.745 SERIAL » [ACK] (0x06) 17:38:38.746 DRIVER « [RES] [SendData] was sent: true 17:38:38.762 SERIAL « 0x010700137100000298 (9 bytes) 17:38:38.762 SERIAL » [ACK] (0x06) 17:38:38.762 DRIVER « [REQ] [SendData] callback id: 113 transmit status: OK 17:38:38.772 SERIAL « 0x010b000400080570063c010abc (13 bytes) 17:38:38.777 CNTRLR [Node 008] [~] [Configuration] 60: 10 => 10 17:38:38.778 SERIAL » [ACK] (0x06) 17:38:38.779 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 1 value: 10 17:38:38.780 CNTRLR « [Node 008] parameter #60 has value: 10 17:38:38.780 CNTRLR » [Node 008] querying parameter #62 value... 17:38:38.784 SERIAL » 0x010a0013080370053e2572f1 (12 bytes) 17:38:38.784 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 114 └─[ConfigurationCCGet] parameter #: 62 17:38:38.786 SERIAL « [ACK] (0x06) 17:38:38.793 SERIAL « 0x0104011301e8 (6 bytes) 17:38:38.793 SERIAL » [ACK] (0x06) 17:38:38.794 DRIVER « [RES] [SendData] was sent: true 17:38:38.809 SERIAL « 0x01070013720000029b (9 bytes) 17:38:38.810 SERIAL » [ACK] (0x06) 17:38:38.810 DRIVER « [REQ] [SendData] callback id: 114 transmit status: OK 17:38:38.820 SERIAL « 0x010c000400080670063e02038434 (14 bytes) 17:38:38.825 CNTRLR [Node 008] [~] [Configuration] 62: 900 => 900 17:38:38.826 SERIAL » [ACK] (0x06) 17:38:38.827 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 62 value size: 2 value: 900 17:38:38.828 CNTRLR « [Node 008] parameter #62 has value: 900 17:38:38.828 CNTRLR » [Node 008] querying parameter #64 value... 17:38:38.837 SERIAL » 0x010a0013080370054025738e (12 bytes) 17:38:38.838 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 115 └─[ConfigurationCCGet] parameter #: 64 17:38:38.840 SERIAL « [ACK] (0x06) 17:38:38.847 SERIAL « 0x0104011301e8 (6 bytes) 17:38:38.847 SERIAL » [ACK] (0x06) 17:38:38.848 DRIVER « [RES] [SendData] was sent: true 17:38:38.863 SERIAL « 0x01070013730000029a (9 bytes) 17:38:38.863 SERIAL » [ACK] (0x06) 17:38:38.864 DRIVER « [REQ] [SendData] callback id: 115 transmit status: OK 17:38:38.874 SERIAL « 0x010c0004000806700640020000cd (14 bytes) 17:38:38.879 CNTRLR [Node 008] [~] [Configuration] 64: 0 => 0 17:38:38.880 SERIAL » [ACK] (0x06) 17:38:38.881 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 64 value size: 2 value: 0 17:38:38.882 CNTRLR « [Node 008] parameter #64 has value: 0 17:38:38.882 CNTRLR » [Node 008] querying parameter #66 value... 17:38:38.886 SERIAL » 0x010a0013080370054225748b (12 bytes) 17:38:38.886 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 116 └─[ConfigurationCCGet] parameter #: 66 17:38:38.888 SERIAL « [ACK] (0x06) 17:38:38.895 SERIAL « 0x0104011301e8 (6 bytes) 17:38:38.896 SERIAL » [ACK] (0x06) 17:38:38.897 DRIVER « [RES] [SendData] was sent: true 17:38:38.911 SERIAL « 0x01070013740000029d (9 bytes) 17:38:38.912 SERIAL » [ACK] (0x06) 17:38:38.912 DRIVER « [REQ] [SendData] callback id: 116 transmit status: OK 17:38:38.923 SERIAL « 0x010c0004000806700642020000cf (14 bytes) 17:38:38.928 CNTRLR [Node 008] [~] [Configuration] 66: 0 => 0 17:38:38.928 SERIAL » [ACK] (0x06) 17:38:38.929 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 66 value size: 2 value: 0 17:38:38.931 CNTRLR « [Node 008] parameter #66 has value: 0 17:38:38.931 CNTRLR » [Node 008] querying parameter #80 value... 17:38:38.940 SERIAL » 0x010a00130803700550257598 (12 bytes) 17:38:38.941 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 117 └─[ConfigurationCCGet] parameter #: 80 17:38:38.943 SERIAL « [ACK] (0x06) 17:38:38.950 SERIAL « 0x0104011301e8 (6 bytes) 17:38:38.950 SERIAL » [ACK] (0x06) 17:38:38.951 DRIVER « [RES] [SendData] was sent: true 17:38:38.966 SERIAL « 0x01070013750000029c (9 bytes) 17:38:38.966 SERIAL » [ACK] (0x06) 17:38:38.967 DRIVER « [REQ] [SendData] callback id: 117 transmit status: OK 17:38:38.977 SERIAL « 0x010b00040008057006500100da (13 bytes) 17:38:38.982 CNTRLR [Node 008] [~] [Configuration] 80: 0 => 0 17:38:38.983 SERIAL » [ACK] (0x06) 17:38:38.984 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 80 value size: 1 value: 0 17:38:38.986 CNTRLR « [Node 008] parameter #80 has value: 0 17:38:38.986 CNTRLR » [Node 008] querying parameter #81 value... 17:38:38.991 SERIAL » 0x010a0013080370055125769a (12 bytes) 17:38:38.991 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 118 └─[ConfigurationCCGet] parameter #: 81 17:38:38.994 SERIAL « [ACK] (0x06) 17:38:39.001 SERIAL « 0x0104011301e8 (6 bytes) 17:38:39.001 SERIAL » [ACK] (0x06) 17:38:39.002 DRIVER « [RES] [SendData] was sent: true 17:38:39.016 SERIAL « 0x01070013760000029f (9 bytes) 17:38:39.017 SERIAL » [ACK] (0x06) 17:38:39.017 DRIVER « [REQ] [SendData] callback id: 118 transmit status: OK 17:38:39.027 SERIAL « 0x010b00040008057006510132e9 (13 bytes) 17:38:39.032 CNTRLR [Node 008] [~] [Configuration] 81: 50 => 50 17:38:39.033 SERIAL » [ACK] (0x06) 17:38:39.034 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 81 value size: 1 value: 50 17:38:39.035 CNTRLR « [Node 008] parameter #81 has value: 50 17:38:39.035 CNTRLR » [Node 008] querying parameter #82 value... 17:38:39.039 SERIAL » 0x010a00130803700552257798 (12 bytes) 17:38:39.039 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 119 └─[ConfigurationCCGet] parameter #: 82 17:38:39.041 SERIAL « [ACK] (0x06) 17:38:39.047 SERIAL « 0x0104011301e8 (6 bytes) 17:38:39.048 SERIAL » [ACK] (0x06) 17:38:39.048 DRIVER « [RES] [SendData] was sent: true 17:38:39.064 SERIAL « 0x01070013770000029e (9 bytes) 17:38:39.065 SERIAL » [ACK] (0x06) 17:38:39.065 DRIVER « [REQ] [SendData] callback id: 119 transmit status: OK 17:38:39.075 SERIAL « 0x010c0004000806700652020064bb (14 bytes) 17:38:39.080 CNTRLR [Node 008] [~] [Configuration] 82: 100 => 100 17:38:39.081 SERIAL » [ACK] (0x06) 17:38:39.082 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 82 value size: 2 value: 100 17:38:39.083 CNTRLR « [Node 008] parameter #82 has value: 100 17:38:39.083 CNTRLR » [Node 008] querying parameter #83 value... 17:38:39.087 SERIAL » 0x010a00130803700553257896 (12 bytes) 17:38:39.087 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 120 └─[ConfigurationCCGet] parameter #: 83 17:38:39.090 SERIAL « [ACK] (0x06) 17:38:39.096 SERIAL « 0x0104011301e8 (6 bytes) 17:38:39.096 SERIAL » [ACK] (0x06) 17:38:39.097 DRIVER « [RES] [SendData] was sent: true 17:38:39.114 SERIAL « 0x010700137800000291 (9 bytes) 17:38:39.115 SERIAL » [ACK] (0x06) 17:38:39.116 DRIVER « [REQ] [SendData] callback id: 120 transmit status: OK 17:38:39.124 SERIAL « 0x010c00040008067006530203e835 (14 bytes) 17:38:39.130 CNTRLR [Node 008] [~] [Configuration] 83: 1000 => 1000 17:38:39.131 SERIAL » [ACK] (0x06) 17:38:39.132 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 83 value size: 2 value: 1000 17:38:39.134 CNTRLR « [Node 008] parameter #83 has value: 1000 17:38:39.134 CNTRLR » [Node 008] querying parameter #86 value... 17:38:39.140 SERIAL » 0x010a00130803700556257992 (12 bytes) 17:38:39.140 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 121 └─[ConfigurationCCGet] parameter #: 86 17:38:39.142 SERIAL « [ACK] (0x06) 17:38:39.149 SERIAL « 0x0104011301e8 (6 bytes) 17:38:39.149 SERIAL » [ACK] (0x06) 17:38:39.150 DRIVER « [RES] [SendData] was sent: true 17:38:39.165 SERIAL « 0x010700137900000290 (9 bytes) 17:38:39.166 SERIAL » [ACK] (0x06) 17:38:39.166 DRIVER « [REQ] [SendData] callback id: 121 transmit status: OK 17:38:39.176 SERIAL « 0x010b00040008057006560112ce (13 bytes) 17:38:39.181 CNTRLR [Node 008] [~] [Configuration] 86: 18 => 18 17:38:39.182 SERIAL » [ACK] (0x06) 17:38:39.183 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 86 value size: 1 value: 18 17:38:39.184 CNTRLR « [Node 008] parameter #86 has value: 18 17:38:39.185 CNTRLR » [Node 008] querying parameter #87 value... 17:38:39.190 SERIAL » 0x010a00130803700557257a90 (12 bytes) 17:38:39.190 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 122 └─[ConfigurationCCGet] parameter #: 87 17:38:39.193 SERIAL « [ACK] (0x06) 17:38:39.199 SERIAL « 0x0104011301e8 (6 bytes) 17:38:39.199 SERIAL » [ACK] (0x06) 17:38:39.200 DRIVER « [RES] [SendData] was sent: true 17:38:39.215 SERIAL « 0x010700137a00000293 (9 bytes) 17:38:39.216 SERIAL » [ACK] (0x06) 17:38:39.217 DRIVER « [REQ] [SendData] callback id: 122 transmit status: OK 17:38:39.227 SERIAL « 0x010b0004000805700657011cc1 (13 bytes) 17:38:39.232 CNTRLR [Node 008] [~] [Configuration] 87: 28 => 28 17:38:39.233 SERIAL » [ACK] (0x06) 17:38:39.234 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 87 value size: 1 value: 28 17:38:39.242 CNTRLR « [Node 008] parameter #87 has value: 28 17:38:39.243 CNTRLR » [Node 008] querying parameter #89 value... 17:38:39.247 SERIAL » 0x010a00130803700559257b9f (12 bytes) 17:38:39.248 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 123 └─[ConfigurationCCGet] parameter #: 89 17:38:39.250 SERIAL « [ACK] (0x06) 17:38:39.261 SERIAL « 0x0104011301e8 (6 bytes) 17:38:39.262 SERIAL » [ACK] (0x06) 17:38:39.262 DRIVER « [RES] [SendData] was sent: true 17:38:39.273 SERIAL « 0x010700137b00000292 (9 bytes) 17:38:39.274 SERIAL » [ACK] (0x06) 17:38:39.274 DRIVER « [REQ] [SendData] callback id: 123 transmit status: OK 17:38:39.288 SERIAL « 0x010b00040008057006590101d2 (13 bytes) 17:38:39.294 CNTRLR [Node 008] [~] [Configuration] 89: 1 => 1 17:38:39.295 SERIAL » [ACK] (0x06) 17:38:39.296 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 89 value size: 1 value: 1 17:38:39.297 CNTRLR « [Node 008] parameter #89 has value: 1 17:38:39.298 CNTRLR [Node 008] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:38:39.331 CNTRLR [Node 008] AlarmSensorCC: doing a partial interview... 17:38:39.331 CNTRLR » [Node 008] querying current value for General Purpose... 17:38:39.337 SERIAL » 0x010a001308039c0100257c29 (12 bytes) 17:38:39.337 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 124 └─[AlarmSensorCCGet] sensor type: General Purpose 17:38:39.340 SERIAL « [ACK] (0x06) 17:38:39.345 SERIAL « 0x0104011301e8 (6 bytes) 17:38:39.346 SERIAL » [ACK] (0x06) 17:38:39.347 DRIVER « [RES] [SendData] was sent: true 17:38:39.363 SERIAL « 0x010700137c00000295 (9 bytes) 17:38:39.363 SERIAL » [ACK] (0x06) 17:38:39.364 DRIVER « [REQ] [SendData] callback id: 124 transmit status: OK 17:38:39.374 SERIAL « 0x010d00040008079c0208000000006f (15 bytes) 17:38:39.375 CNTRLR [Node 008] [~] [Alarm Sensor] state[0]: false => false [Endpoint 0] 17:38:39.376 CNTRLR [Node 008] [+] [Alarm Sensor] severity[0]: undefined [Endpoint 0] 17:38:39.377 CNTRLR [Node 008] [+] [Alarm Sensor] duration[0]: undefined [Endpoint 0] 17:38:39.377 SERIAL » [ACK] (0x06) 17:38:39.378 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: false 17:38:39.380 CNTRLR « [Node 008] received current value for General Purpose: state: false 17:38:39.380 CNTRLR [Node 008] [~] [Alarm Sensor] interviewComplete: true [Endpoint 0] [internal] => true 17:38:39.381 CNTRLR [Node 008] MultiChannelAssociationCC: doing a partial interview... 17:38:39.381 CNTRLR » [Node 008] querying multi channel association group #1... 17:38:39.385 SERIAL » 0x010a001308038e0201257d38 (12 bytes) 17:38:39.385 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 125 └─[MultiChannelAssociationCCGet] group id: 1 17:38:39.388 SERIAL « [ACK] (0x06) 17:38:39.393 SERIAL « 0x0104011301e8 (6 bytes) 17:38:39.393 SERIAL » [ACK] (0x06) 17:38:39.394 DRIVER « [RES] [SendData] was sent: true 17:38:39.410 SERIAL « 0x010700137d00000294 (9 bytes) 17:38:39.411 SERIAL » [ACK] (0x06) 17:38:39.411 DRIVER « [REQ] [SendData] callback id: 125 transmit status: OK 17:38:39.422 SERIAL « 0x010c00040008068e030105000171 (14 bytes) 17:38:39.422 SERIAL » [ACK] (0x06) 17:38:39.423 CNTRLR [Node 008] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 17:38:39.424 CNTRLR [Node 008] [~] [Multi Channel Association] nodeIds[1]: 1 => 1 17:38:39.425 CNTRLR [Node 008] [~] [Multi Channel Association] endpoints[1]: => 17:38:39.426 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: 1 endpoints: 17:38:39.427 CNTRLR « [Node 008] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 17:38:39.427 CNTRLR » [Node 008] querying multi channel association group #2... 17:38:39.436 SERIAL » 0x010a001308038e0202257e38 (12 bytes) 17:38:39.436 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 126 └─[MultiChannelAssociationCCGet] group id: 2 17:38:39.443 SERIAL « [ACK] (0x06) 17:38:39.446 SERIAL « 0x0104011301e8 (6 bytes) 17:38:39.447 SERIAL » [ACK] (0x06) 17:38:39.450 DRIVER « [RES] [SendData] was sent: true 17:38:39.476 SERIAL « 0x010700137e00000297 (9 bytes) 17:38:39.476 SERIAL » [ACK] (0x06) 17:38:39.477 DRIVER « [REQ] [SendData] callback id: 126 transmit status: OK 17:38:39.481 SERIAL « 0x010c00040008068e030205000172 (14 bytes) 17:38:39.482 SERIAL » [ACK] (0x06) 17:38:39.483 CNTRLR [Node 008] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 17:38:39.485 CNTRLR [Node 008] [~] [Multi Channel Association] nodeIds[2]: 1 => 1 17:38:39.486 CNTRLR [Node 008] [~] [Multi Channel Association] endpoints[2]: => 17:38:39.487 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: 1 endpoints: 17:38:39.490 CNTRLR « [Node 008] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 17:38:39.491 CNTRLR » [Node 008] querying additional non-multi-channel association groups... 17:38:39.491 CNTRLR » [Node 008] querying association group #3... 17:38:39.499 SERIAL » 0x010a00130803850203257f33 (12 bytes) 17:38:39.499 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 127 └─[AssociationCCGet] group id: 3 17:38:39.508 SERIAL « [ACK] (0x06) 17:38:39.510 SERIAL « 0x0104011301e8 (6 bytes) 17:38:39.513 SERIAL » [ACK] (0x06) 17:38:39.514 DRIVER « [RES] [SendData] was sent: true 17:38:39.530 SERIAL « 0x010700137f00000296 (9 bytes) 17:38:39.531 SERIAL » [ACK] (0x06) 17:38:39.541 DRIVER « [REQ] [SendData] callback id: 127 transmit status: OK 17:38:39.577 SERIAL « 0x010c00040008068503030100017c (14 bytes) 17:38:39.578 SERIAL » [ACK] (0x06) 17:38:39.581 CNTRLR [Node 008] [~] [Association] maxNodes[3]: 1 => 1 [internal] 17:38:39.581 CNTRLR [Node 008] [~] [Association] nodeIds[3]: 1 => 1 [internal] 17:38:39.581 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 17:38:39.584 CNTRLR « [Node 008] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 17:38:39.584 CNTRLR [Node 008] [~] [Association] hasLifeline: true => true [internal] 17:38:39.585 CNTRLR [Node 008] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:38:39.585 CNTRLR [Node 008] Interview stage completed: CommandClasses 17:38:39.585 CNTRLR [Node 008] Interview stage completed: OverwriteConfig 17:38:39.585 CNTRLR » [Node 008] requesting node neighbors... 17:38:39.588 SERIAL » 0x010700800800000070 (9 bytes) 17:38:39.589 DRIVER » [Node 008] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:38:39.593 SERIAL « [ACK] (0x06) 17:38:39.596 SERIAL « 0x01200180050000000000000000000000000000000000000000000000000000000 (34 bytes) 05b 17:38:39.596 SERIAL » [ACK] (0x06) 17:38:39.597 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3 17:38:39.599 CNTRLR « [Node 008] node neighbors received: 1, 3 17:38:39.599 CNTRLR [Node 008] Interview stage completed: Neighbors 17:38:39.599 CNTRLR [Node 008] Interview completed 17:38:40.600 CNTRLR » [Node 008] Sending node back to sleep... 17:38:40.607 SERIAL » 0x01090013080284082580c6 (11 bytes) 17:38:40.608 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 128 └─[WakeUpCCNoMoreInformation] 17:38:40.610 SERIAL « [ACK] (0x06) 17:38:40.616 SERIAL « 0x0104011301e8 (6 bytes) 17:38:40.616 SERIAL » [ACK] (0x06) 17:38:40.617 DRIVER « [RES] [SendData] was sent: true 17:38:40.633 SERIAL « 0x010700138000000269 (9 bytes) 17:38:40.633 SERIAL » [ACK] (0x06) 17:38:40.634 DRIVER « [REQ] [SendData] callback id: 128 transmit status: OK 17:38:40.643 CNTRLR [Node 008] The node is now asleep. 17:38:40.962 SERIAL « 0x010c000400030631050422040ce8 (14 bytes) 17:38:40.964 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:38:40.965 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 220.2 => 103.6 [Endpoint 0] 17:38:40.966 SERIAL » [ACK] (0x06) 17:38:40.968 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 103.6 17:38:41.962 SERIAL « 0x010c000400030631050422088f67 (14 bytes) 17:38:41.963 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:38:41.963 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 103.6 => 219.1 [Endpoint 0] 17:38:41.964 SERIAL » [ACK] (0x06) 17:38:41.965 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 219.1 17:38:42.962 SERIAL « 0x010c00040003063105042206ca2c (14 bytes) 17:38:42.964 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:38:42.965 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 219.1 => 173.8 [Endpoint 0] 17:38:42.965 SERIAL » [ACK] (0x06) 17:38:42.966 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 173.8 17:38:43.962 SERIAL « 0x010c00040003063105042202ec0e (14 bytes) 17:38:43.963 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:38:43.964 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 173.8 => 74.8 [Endpoint 0] 17:38:43.964 SERIAL » [ACK] (0x06) 17:38:43.965 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 74.8 17:38:44.789 SERIAL « 0x01090004001e033003ff23 (11 bytes) 17:38:44.790 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:38:44.792 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:38:44.793 SERIAL » [ACK] (0x06) 17:38:44.795 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:38:44.843 SERIAL « 0x01090004001e032001ff31 (11 bytes) 17:38:44.845 SERIAL » [ACK] (0x06) 17:38:44.846 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:38:44.848 CNTRLR [Node 030] treating BasicCC Set as a report 17:38:44.849 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:38:44.962 SERIAL « 0x010c00040003063105042203d734 (14 bytes) 17:38:44.963 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:38:44.964 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 74.8 => 98.3 [Endpoint 0] 17:38:44.965 SERIAL » [ACK] (0x06) 17:38:44.966 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 98.3 17:38:45.040 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 17:38:45.041 SERIAL » [ACK] (0x06) 17:38:45.041 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 17:38:45.043 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 17:38:46.963 SERIAL « 0x010c00040003063105042208ef07 (14 bytes) 17:38:46.964 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:38:46.965 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 98.3 => 228.7 [Endpoint 0] 17:38:46.967 SERIAL » [ACK] (0x06) 17:38:46.969 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 228.7 17:38:52.103 SERIAL « 0x01090004000b0380034b32 (11 bytes) 17:38:52.104 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 17:38:52.104 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 17:38:52.105 SERIAL » [ACK] (0x06) 17:38:52.106 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 17:38:52.162 SERIAL « 0x010c0004000b064303014203e812 (14 bytes) 17:38:52.165 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 0] 17:38:52.166 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 17:38:52.166 SERIAL » [ACK] (0x06) 17:38:52.168 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 17:38:52.219 SERIAL « 0x010a0004000b044608007fcf (12 bytes) 17:38:52.222 CNTRLR [Node 011] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 17:38:52.222 CNTRLR [Node 011] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 17:38:52.223 SERIAL » [ACK] (0x06) 17:38:52.224 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ClimateControlScheduleCCOverrideReport] override type: None override state: Unused 17:38:52.274 SERIAL « 0x01080004000b02840779 (10 bytes) 17:38:52.275 SERIAL » [ACK] (0x06) 17:38:52.276 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:38:52.278 CNTRLR « [Node 011] received wakeup notification 17:38:52.278 CNTRLR [Node 011] The node is now awake. 17:38:52.279 CNTRLR [Node 011] expects some queries after wake up, so it shall receive 17:38:52.280 CNTRLR [Node 011] compat query "Battery"::get() 17:38:52.288 SERIAL » 0x010900130b0280022581ca (11 bytes) 17:38:52.293 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 129 └─[BatteryCCGet] 17:38:52.297 SERIAL « [ACK] (0x06) 17:38:52.306 SERIAL « 0x0104011301e8 (6 bytes) 17:38:52.307 SERIAL » [ACK] (0x06) 17:38:52.308 DRIVER « [RES] [SendData] was sent: true 17:38:52.325 SERIAL « 0x010700138100000369 (9 bytes) 17:38:52.326 SERIAL » [ACK] (0x06) 17:38:52.326 DRIVER « [REQ] [SendData] callback id: 129 transmit status: OK 17:38:52.337 SERIAL « 0x01090004000b0380034b32 (11 bytes) 17:38:52.339 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 17:38:52.340 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 17:38:52.340 SERIAL » [ACK] (0x06) 17:38:52.342 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 17:38:52.348 SERIAL » 0x010a00130b03430201258209 (12 bytes) 17:38:52.349 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 130 └─[ThermostatSetpointCCGet] setpoint type: Heating 17:38:52.350 CNTRLR « [Node 011] received response for battery information: level: 75 17:38:52.351 CNTRLR [Node 011] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:38:52.397 SERIAL « [ACK] (0x06) 17:38:52.402 SERIAL « 0x0104011301e8 (6 bytes) 17:38:52.402 SERIAL » [ACK] (0x06) 17:38:52.403 DRIVER « [RES] [SendData] was sent: true 17:38:52.406 CNTRLR [Node 011] WakeUpCC: doing a partial interview... 17:38:52.406 CNTRLR » [Node 011] retrieving wakeup interval from the device... 17:38:52.408 SERIAL « 0x01070013820000026b (9 bytes) 17:38:52.408 SERIAL » [ACK] (0x06) 17:38:52.408 DRIVER « [REQ] [SendData] callback id: 130 transmit status: OK 17:38:52.412 SERIAL « 0x010c0004000b064303014203e812 (14 bytes) 17:38:52.413 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 0] 17:38:52.414 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 17:38:52.414 SERIAL » [ACK] (0x06) 17:38:52.415 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 17:38:52.425 SERIAL » 0x010900130b0280022583c8 (11 bytes) 17:38:52.426 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 131 └─[BatteryCCGet] 17:38:52.427 CNTRLR [Node 011] API call successful 17:38:52.430 SERIAL « [ACK] (0x06) 17:38:52.435 SERIAL « 0x0104011301e8 (6 bytes) 17:38:52.435 SERIAL » [ACK] (0x06) 17:38:52.436 DRIVER « [RES] [SendData] was sent: true 17:38:52.452 SERIAL « 0x01070013830000026a (9 bytes) 17:38:52.452 SERIAL » [ACK] (0x06) 17:38:52.452 DRIVER « [REQ] [SendData] callback id: 131 transmit status: OK 17:38:52.462 SERIAL « 0x01090004000b0380034b32 (11 bytes) 17:38:52.462 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 17:38:52.463 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 17:38:52.463 SERIAL » [ACK] (0x06) 17:38:52.465 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 17:38:52.468 SERIAL » 0x010900130b0284052584cc (11 bytes) 17:38:52.468 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 132 └─[WakeUpCCIntervalGet] 17:38:52.469 CNTRLR [Node 011] API call successful 17:38:52.469 CNTRLR [Node 011] compat query "Thermostat Setpoint"::get(1) 17:38:52.475 SERIAL « [ACK] (0x06) 17:38:52.476 SERIAL « 0x0104011301e8 (6 bytes) 17:38:52.477 SERIAL » [ACK] (0x06) 17:38:52.478 DRIVER « [RES] [SendData] was sent: true 17:38:52.493 SERIAL « 0x01070013840000026d (9 bytes) 17:38:52.494 SERIAL » [ACK] (0x06) 17:38:52.495 DRIVER « [REQ] [SendData] callback id: 132 transmit status: OK 17:38:52.504 SERIAL « 0x010c0004000b06840600038401fe (14 bytes) 17:38:52.505 CNTRLR [Node 011] [~] [Wake Up] wakeUpInterval: 900 => 900 [Endpoint 0] 17:38:52.506 CNTRLR [Node 011] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 17:38:52.506 SERIAL » [ACK] (0x06) 17:38:52.508 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 900 seconds controller node id: 1 17:38:52.511 SERIAL » 0x010a00130b0343020125850e (12 bytes) 17:38:52.511 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 133 └─[ThermostatSetpointCCGet] setpoint type: Heating 17:38:52.512 CNTRLR « [Node 011] received wakeup configuration: wakeup interval: 900 seconds controller node: 1 17:38:52.512 CNTRLR [Node 011] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:38:52.513 CNTRLR [Node 011] ThermostatSetpointCC: doing a partial interview... 17:38:52.513 CNTRLR » [Node 011] querying current value of setpoint Heating... 17:38:52.518 SERIAL « [ACK] (0x06) 17:38:52.519 SERIAL « 0x0104011301e8 (6 bytes) 17:38:52.520 SERIAL » [ACK] (0x06) 17:38:52.521 DRIVER « [RES] [SendData] was sent: true 17:38:52.536 SERIAL « 0x01070013850000036d (9 bytes) 17:38:52.537 SERIAL » [ACK] (0x06) 17:38:52.537 DRIVER « [REQ] [SendData] callback id: 133 transmit status: OK 17:38:52.547 SERIAL « 0x010c0004000b064303014203e812 (14 bytes) 17:38:52.548 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 0] 17:38:52.549 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 17:38:52.549 SERIAL » [ACK] (0x06) 17:38:52.550 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 17:38:52.557 SERIAL » 0x010a00130b0343020125860d (12 bytes) 17:38:52.557 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 134 └─[ThermostatSetpointCCGet] setpoint type: Heating 17:38:52.558 CNTRLR [Node 011] API call successful 17:38:52.559 SERIAL « [ACK] (0x06) 17:38:52.565 SERIAL « 0x0104011301e8 (6 bytes) 17:38:52.566 SERIAL » [ACK] (0x06) 17:38:52.566 DRIVER « [RES] [SendData] was sent: true 17:38:52.582 SERIAL « 0x01070013860000026f (9 bytes) 17:38:52.583 SERIAL » [ACK] (0x06) 17:38:52.583 DRIVER « [REQ] [SendData] callback id: 134 transmit status: OK 17:38:52.593 SERIAL « 0x010c0004000b064303014203e812 (14 bytes) 17:38:52.594 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 0] 17:38:52.595 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 17:38:52.595 SERIAL » [ACK] (0x06) 17:38:52.596 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 17:38:52.598 CNTRLR « [Node 011] received current value of setpoint Heating: 10 °C 17:38:52.598 CNTRLR [Node 011] [~] [Thermostat Setpoint] interviewComplete [Endpoint 0] [internal] : true => true 17:38:52.638 CNTRLR [Node 011] ProtectionCC: doing a partial interview... 17:38:52.638 CNTRLR » [Node 011] querying protection status... 17:38:52.642 SERIAL » 0x010900130b027502258739 (11 bytes) 17:38:52.642 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 135 └─[ProtectionCCGet] 17:38:52.644 SERIAL « [ACK] (0x06) 17:38:52.650 SERIAL « 0x0104011301e8 (6 bytes) 17:38:52.650 SERIAL » [ACK] (0x06) 17:38:52.651 DRIVER « [RES] [SendData] was sent: true 17:38:52.667 SERIAL « 0x01070013870000036f (9 bytes) 17:38:52.668 SERIAL » [ACK] (0x06) 17:38:52.668 DRIVER « [REQ] [SendData] callback id: 135 transmit status: OK 17:38:52.678 SERIAL « 0x010a0004000b047503000088 (12 bytes) 17:38:52.678 CNTRLR [Node 011] [~] [Protection] local: 0 => 0 [Endpoint 0] 17:38:52.679 SERIAL » [ACK] (0x06) 17:38:52.680 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 17:38:52.682 CNTRLR « [Node 011] received protection status: local: Unprotected rf Unprotected 17:38:52.682 CNTRLR [Node 011] [~] [Protection] interviewComplete: true => [Endpoint 0] [internal] true 17:38:52.682 CNTRLR [Node 011] ClockCC: doing a partial interview... 17:38:52.683 CNTRLR » [Node 011] requesting current clock setting... 17:38:52.689 SERIAL » 0x010900130b0281052588c5 (11 bytes) 17:38:52.689 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 136 └─[ClockCCGet] 17:38:52.691 SERIAL « [ACK] (0x06) 17:38:52.697 SERIAL « 0x0104011301e8 (6 bytes) 17:38:52.698 SERIAL » [ACK] (0x06) 17:38:52.698 DRIVER « [RES] [SendData] was sent: true 17:38:52.714 SERIAL « 0x010700138800000261 (9 bytes) 17:38:52.715 SERIAL » [ACK] (0x06) 17:38:52.715 DRIVER « [REQ] [SendData] callback id: 136 transmit status: OK 17:38:52.725 SERIAL « 0x010a0004000b048106d506aa (12 bytes) 17:38:52.726 SERIAL » [ACK] (0x06) 17:38:52.727 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ClockCCReport] clock setting: Saturday, 21:06 17:38:52.729 CNTRLR « [Node 011] received current clock setting: Saturday, 21:06 17:38:52.729 CNTRLR [Node 011] [~] [Clock] interviewComplete: true => true [Endpoint 0] [internal] 17:38:52.729 CNTRLR [Node 011] Interview stage completed: CommandClasses 17:38:52.729 CNTRLR [Node 011] Interview stage completed: OverwriteConfig 17:38:52.729 CNTRLR » [Node 011] requesting node neighbors... 17:38:52.733 SERIAL » 0x010700800b00000073 (9 bytes) 17:38:52.733 DRIVER » [Node 011] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:38:52.735 SERIAL « [ACK] (0x06) 17:38:52.738 SERIAL « 0x01200180450300000000000000000000000000000000000000000000000000000 (34 bytes) 018 17:38:52.738 SERIAL » [ACK] (0x06) 17:38:52.739 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 7, 9, 10 17:38:52.743 CNTRLR « [Node 011] node neighbors received: 1, 3, 7, 9, 10 17:38:52.743 CNTRLR [Node 011] Interview stage completed: Neighbors 17:38:52.743 CNTRLR [Node 011] Interview completed 17:38:52.876 SERIAL « 0x01090004001b033003ff26 (11 bytes) 17:38:52.877 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:38:52.878 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:38:52.879 SERIAL » [ACK] (0x06) 17:38:52.880 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:38:52.929 SERIAL « 0x01090004001b032001ff34 (11 bytes) 17:38:52.930 SERIAL » [ACK] (0x06) 17:38:52.931 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:38:52.932 CNTRLR [Node 027] treating BasicCC Set as a report 17:38:52.932 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:38:53.744 CNTRLR » [Node 011] Sending node back to sleep... 17:38:53.755 SERIAL » 0x010900130b0284082589cc (11 bytes) 17:38:53.755 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 137 └─[WakeUpCCNoMoreInformation] 17:38:53.758 SERIAL « [ACK] (0x06) 17:38:53.764 SERIAL « 0x0104011301e8 (6 bytes) 17:38:53.765 SERIAL » [ACK] (0x06) 17:38:53.766 DRIVER « [RES] [SendData] was sent: true 17:38:53.781 SERIAL « 0x010700138900000260 (9 bytes) 17:38:53.782 SERIAL » [ACK] (0x06) 17:38:53.782 DRIVER « [REQ] [SendData] callback id: 137 transmit status: OK 17:38:53.787 CNTRLR [Node 011] The node is now asleep. 17:38:56.469 SERIAL « 0x01090004000803300300ca (11 bytes) 17:38:56.470 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:38:56.471 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:38:56.472 SERIAL » [ACK] (0x06) 17:38:56.474 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:38:56.523 SERIAL « 0x01090004000803200100d8 (11 bytes) 17:38:56.524 SERIAL » [ACK] (0x06) 17:38:56.525 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:38:56.526 CNTRLR [Node 008] treating BasicCC Set as a report 17:38:56.527 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:39:12.965 SERIAL « 0x010c0004000306310504220705e2 (14 bytes) 17:39:12.966 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:39:12.967 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 228.7 => 179.7 [Endpoint 0] 17:39:12.967 SERIAL » [ACK] (0x06) 17:39:12.968 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 179.7 17:39:13.965 SERIAL « 0x010c00040003063105042208f51d (14 bytes) 17:39:13.967 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:39:13.968 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 179.7 => 229.3 [Endpoint 0] 17:39:13.969 SERIAL » [ACK] (0x06) 17:39:13.971 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 229.3 17:39:15.321 SERIAL « 0x01090004001e03300300dc (11 bytes) 17:39:15.321 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:39:15.322 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:39:15.322 SERIAL » [ACK] (0x06) 17:39:15.323 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:39:15.375 SERIAL « 0x01090004001e03200100ce (11 bytes) 17:39:15.375 SERIAL » [ACK] (0x06) 17:39:15.376 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:39:15.377 CNTRLR [Node 030] treating BasicCC Set as a report 17:39:15.377 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:39:15.966 SERIAL « 0x010c000400030631050422078661 (14 bytes) 17:39:15.966 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:39:15.967 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 229.3 => 192.6 [Endpoint 0] 17:39:15.967 SERIAL » [ACK] (0x06) 17:39:15.968 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 192.6 17:39:16.385 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 17:39:16.386 SERIAL » [ACK] (0x06) 17:39:16.388 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  17:39:16.391 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 17:39:21.966 SERIAL « 0x010c00040003063105042208ce26 (14 bytes) 17:39:21.968 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:39:21.969 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 192.6 => 225.4 [Endpoint 0] 17:39:21.970 SERIAL » [ACK] (0x06) 17:39:21.974 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 225.4 17:39:22.869 SERIAL « 0x01090004001b03300300d9 (11 bytes) 17:39:22.871 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:39:22.872 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:39:22.873 SERIAL » [ACK] (0x06) 17:39:22.874 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:39:22.924 SERIAL « 0x01090004001b03200100cb (11 bytes) 17:39:22.925 SERIAL » [ACK] (0x06) 17:39:22.926 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:39:22.927 CNTRLR [Node 027] treating BasicCC Set as a report 17:39:22.928 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:39:27.967 SERIAL « 0x010c000400030631050422077691 (14 bytes) 17:39:27.968 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:39:27.968 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 225.4 => 191 [Endpoint 0] 17:39:27.969 SERIAL » [ACK] (0x06) 17:39:27.969 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 191 17:39:42.984 SERIAL « 0x01080004001b02840769 (10 bytes) 17:39:42.984 SERIAL » [ACK] (0x06) 17:39:42.985 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:39:42.986 CNTRLR « [Node 027] received wakeup notification 17:39:42.986 CNTRLR [Node 027] The node is now awake. 17:39:42.990 SERIAL » 0x010900131b028002258ad1 (11 bytes) 17:39:42.990 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 138 └─[BatteryCCGet] 17:39:42.992 SERIAL « [ACK] (0x06) 17:39:42.998 SERIAL « 0x0104011301e8 (6 bytes) 17:39:42.998 SERIAL » [ACK] (0x06) 17:39:42.999 DRIVER « [RES] [SendData] was sent: true 17:39:43.027 SERIAL « 0x010700138a00000465 (9 bytes) 17:39:43.027 SERIAL » [ACK] (0x06) 17:39:43.028 DRIVER « [REQ] [SendData] callback id: 138 transmit status: OK 17:39:43.037 SERIAL « 0x01090004001b038003640d (11 bytes) 17:39:43.038 CNTRLR [Node 027] [~] [Battery] level: 100 => 100 [Endpoint 0] 17:39:43.039 CNTRLR [Node 027] [~] [Battery] isLow: false => false [Endpoint 0] 17:39:43.039 SERIAL » [ACK] (0x06) 17:39:43.040 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 17:39:43.041 CNTRLR « [Node 027] received response for battery information: level: 100 17:39:43.042 CNTRLR [Node 027] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:39:43.077 CNTRLR [Node 027] WakeUpCC: doing a partial interview... 17:39:43.078 CNTRLR » [Node 027] retrieving wakeup interval from the device... 17:39:43.083 SERIAL » 0x010900131b028405258bd3 (11 bytes) 17:39:43.084 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 139 └─[WakeUpCCIntervalGet] 17:39:43.085 SERIAL « 0x010c000400030631050422042dc9 (14 bytes) 17:39:43.086 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:39:43.086 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 191 => 106.9 [Endpoint 0] 17:39:43.087 SERIAL » [ACK] (0x06) 17:39:43.088 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 106.9 17:39:43.089 SERIAL « [CAN] (0x18) 17:39:43.090 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 17:39:43.190 SERIAL » 0x010900131b028405258bd3 (11 bytes) 17:39:43.191 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 139 └─[WakeUpCCIntervalGet] 17:39:43.192 SERIAL « [ACK] (0x06) 17:39:43.198 SERIAL « 0x0104011301e8 (6 bytes) 17:39:43.199 SERIAL » [ACK] (0x06) 17:39:43.199 DRIVER « [RES] [SendData] was sent: true 17:39:43.215 SERIAL « 0x010700138b00000262 (9 bytes) 17:39:43.216 SERIAL » [ACK] (0x06) 17:39:43.216 DRIVER « [REQ] [SendData] callback id: 139 transmit status: OK 17:39:43.227 SERIAL « 0x010c0004001b06840600038401ee (14 bytes) 17:39:43.227 CNTRLR [Node 027] [~] [Wake Up] wakeUpInterval: 900 => 900 [Endpoint 0] 17:39:43.228 CNTRLR [Node 027] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 17:39:43.228 SERIAL » [ACK] (0x06) 17:39:43.229 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 900 seconds controller node id: 1 17:39:43.231 CNTRLR « [Node 027] received wakeup configuration: wakeup interval: 900 seconds controller node: 1 17:39:43.231 CNTRLR [Node 027] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:39:43.269 CNTRLR [Node 027] AssociationCC: doing a partial interview... 17:39:43.269 CNTRLR [Node 027] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:39:43.269 CNTRLR [Node 027] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:39:43.270 CNTRLR [Node 027] BasicCC: doing a partial interview... 17:39:43.270 CNTRLR » [Node 027] querying Basic CC state... 17:39:43.274 SERIAL » 0x010900131b022002258c77 (11 bytes) 17:39:43.274 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 140 └─[BasicCCGet] 17:39:43.276 SERIAL « [ACK] (0x06) 17:39:43.282 SERIAL « 0x0104011301e8 (6 bytes) 17:39:43.282 SERIAL » [ACK] (0x06) 17:39:43.283 DRIVER « [RES] [SendData] was sent: true 17:39:43.299 SERIAL « 0x010700138c00000265 (9 bytes) 17:39:43.300 SERIAL » [ACK] (0x06) 17:39:43.301 DRIVER « [REQ] [SendData] callback id: 140 transmit status: OK 17:39:43.310 SERIAL « 0x01090004001b03200300c9 (11 bytes) 17:39:43.311 SERIAL » [ACK] (0x06) 17:39:43.311 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCReport] current value: 0 17:39:43.314 CNTRLR « [Node 027] received Basic CC state: current value: 0 17:39:43.315 CNTRLR [Node 027] [~] [Basic] interviewComplete: true => true [Endpoint 0] [internal] 17:39:43.315 CNTRLR [Node 027] BinarySensorCC: doing a partial interview... 17:39:43.315 CNTRLR » [Node 027] querying current value... 17:39:43.323 SERIAL » 0x010900131b023002258d66 (11 bytes) 17:39:43.323 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 141 └─[BinarySensorCCGet] type: Any 17:39:43.326 SERIAL « [ACK] (0x06) 17:39:43.332 SERIAL « 0x0104011301e8 (6 bytes) 17:39:43.332 SERIAL » [ACK] (0x06) 17:39:43.333 DRIVER « [RES] [SendData] was sent: true 17:39:43.348 SERIAL « 0x010700138d00000365 (9 bytes) 17:39:43.349 SERIAL » [ACK] (0x06) 17:39:43.350 DRIVER « [REQ] [SendData] callback id: 141 transmit status: OK 17:39:43.359 SERIAL « 0x01090004001b03300300d9 (11 bytes) 17:39:43.360 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:39:43.361 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:39:43.362 SERIAL » [ACK] (0x06) 17:39:43.363 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:39:43.366 CNTRLR « [Node 027] received current value: false 17:39:43.366 CNTRLR [Node 027] [~] [Binary Sensor] interviewComplete: true [Endpoint 0] [internal] => true 17:39:43.367 CNTRLR [Node 027] MultilevelSensorCC: doing a partial interview... 17:39:43.367 CNTRLR » [Node 027] querying Air temperature sensor reading... 17:39:43.378 SERIAL » 0x010b00131b0431040100258e67 (13 bytes) 17:39:43.379 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 142 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 17:39:43.381 SERIAL « [ACK] (0x06) 17:39:43.387 SERIAL « 0x0104011301e8 (6 bytes) 17:39:43.387 SERIAL » [ACK] (0x06) 17:39:43.388 DRIVER « [RES] [SendData] was sent: true 17:39:43.404 SERIAL « 0x010700138e00000267 (9 bytes) 17:39:43.404 SERIAL » [ACK] (0x06) 17:39:43.405 DRIVER « [REQ] [SendData] callback id: 142 transmit status: OK 17:39:43.415 SERIAL « 0x010c0004001b063105012200c33e (14 bytes) 17:39:43.416 CNTRLR [Node 027] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 17:39:43.416 CNTRLR [Node 027] [~] [Multilevel Sensor] Air temperature: 19.5 => 19.5 [Endpoint 0] 17:39:43.417 SERIAL » [ACK] (0x06) 17:39:43.418 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 19.5 17:39:43.419 CNTRLR « [Node 027] received current Air temperature sensor reading: 19.5 °C 17:39:43.419 CNTRLR » [Node 027] querying Illuminance sensor reading... 17:39:43.423 SERIAL » 0x010b00131b0431040308258f6c (13 bytes) 17:39:43.424 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 143 └─[MultilevelSensorCCGet] sensor type: Illuminance scale: Lux 17:39:43.457 SERIAL « [ACK] (0x06) 17:39:43.458 SERIAL « 0x0104011301e8 (6 bytes) 17:39:43.458 SERIAL » [ACK] (0x06) 17:39:43.461 DRIVER « [RES] [SendData] was sent: true 17:39:43.464 SERIAL « 0x010700138f00000367 (9 bytes) 17:39:43.464 SERIAL » [ACK] (0x06) 17:39:43.465 DRIVER « [REQ] [SendData] callback id: 143 transmit status: OK 17:39:43.467 SERIAL « 0x010c0004001b063105030a001dca (14 bytes) 17:39:43.468 CNTRLR [Node 027] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 17:39:43.468 CNTRLR [Node 027] [~] [Multilevel Sensor] Illuminance: 1 => 29 [Endpoint 0] 17:39:43.469 SERIAL » [ACK] (0x06) 17:39:43.470 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 29 17:39:43.471 CNTRLR « [Node 027] received current Illuminance sensor reading: 29 Lux 17:39:43.471 CNTRLR [Node 027] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 17:39:43.472 CNTRLR [Node 027] ConfigurationCC: Loading configuration parameters from device confi g 17:39:43.478 CNTRLR [Node 027] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:39:43.479 CNTRLR [Node 027] [Configuration] 1: metadata updated 17:39:43.480 CNTRLR [Node 027] [Configuration] 2: metadata updated 17:39:43.481 CNTRLR [Node 027] [Configuration] 3: metadata updated 17:39:43.482 CNTRLR [Node 027] [Configuration] 4: metadata updated 17:39:43.485 CNTRLR [Node 027] [Configuration] 6: metadata updated 17:39:43.486 CNTRLR [Node 027] [Configuration] 8: metadata updated 17:39:43.487 CNTRLR [Node 027] [Configuration] 9: metadata updated 17:39:43.488 CNTRLR [Node 027] [Configuration] 12: metadata updated 17:39:43.489 CNTRLR [Node 027] [Configuration] 14: metadata updated 17:39:43.490 CNTRLR [Node 027] [Configuration] 16: metadata updated 17:39:43.491 CNTRLR [Node 027] [Configuration] 20: metadata updated 17:39:43.495 CNTRLR [Node 027] [Configuration] 22: metadata updated 17:39:43.496 CNTRLR [Node 027] [Configuration] 24: metadata updated 17:39:43.498 CNTRLR [Node 027] [Configuration] 26: metadata updated 17:39:43.499 CNTRLR [Node 027] [Configuration] 40: metadata updated 17:39:43.500 CNTRLR [Node 027] [Configuration] 42: metadata updated 17:39:43.501 CNTRLR [Node 027] [Configuration] 60: metadata updated 17:39:43.502 CNTRLR [Node 027] [Configuration] 62: metadata updated 17:39:43.504 CNTRLR [Node 027] [Configuration] 64: metadata updated 17:39:43.505 CNTRLR [Node 027] [Configuration] 66: metadata updated 17:39:43.506 CNTRLR [Node 027] [Configuration] 80: metadata updated 17:39:43.509 CNTRLR [Node 027] [Configuration] 81: metadata updated 17:39:43.510 CNTRLR [Node 027] [Configuration] 82: metadata updated 17:39:43.511 CNTRLR [Node 027] [Configuration] 83: metadata updated 17:39:43.512 CNTRLR [Node 027] [Configuration] 86: metadata updated 17:39:43.513 CNTRLR [Node 027] [Configuration] 87: metadata updated 17:39:43.514 CNTRLR [Node 027] [Configuration] 89: metadata updated 17:39:43.515 CNTRLR [Node 027] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:39:43.515 CNTRLR » [Node 027] querying parameter #1 value... 17:39:43.519 SERIAL » 0x010a00131b0370050125903f (12 bytes) 17:39:43.520 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 144 └─[ConfigurationCCGet] parameter #: 1 17:39:43.528 SERIAL « [ACK] (0x06) 17:39:43.531 SERIAL « 0x0104011301e8 (6 bytes) 17:39:43.532 SERIAL » [ACK] (0x06) 17:39:43.539 DRIVER « [RES] [SendData] was sent: true 17:39:43.562 SERIAL « 0x010700139000000279 (9 bytes) 17:39:43.563 SERIAL » [ACK] (0x06) 17:39:43.567 DRIVER « [REQ] [SendData] callback id: 144 transmit status: OK 17:39:43.580 SERIAL « 0x010b0004001b05700601010a92 (13 bytes) 17:39:43.586 CNTRLR [Node 027] [~] [Configuration] 1: 10 => 10 17:39:43.587 SERIAL » [ACK] (0x06) 17:39:43.590 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 10 17:39:43.593 CNTRLR « [Node 027] parameter #1 has value: 10 17:39:43.594 CNTRLR » [Node 027] querying parameter #2 value... 17:39:43.603 SERIAL » 0x010a00131b0370050225913d (12 bytes) 17:39:43.603 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 145 └─[ConfigurationCCGet] parameter #: 2 17:39:43.617 SERIAL « [ACK] (0x06) 17:39:43.618 SERIAL « 0x0104011301e8 (6 bytes) 17:39:43.618 SERIAL » [ACK] (0x06) 17:39:43.619 DRIVER « [RES] [SendData] was sent: true 17:39:43.659 SERIAL « 0x010700139100000379 (9 bytes) 17:39:43.660 SERIAL » [ACK] (0x06) 17:39:43.662 DRIVER « [REQ] [SendData] callback id: 145 transmit status: OK 17:39:43.667 SERIAL « 0x010b0004001b05700602010f94 (13 bytes) 17:39:43.672 CNTRLR [Node 027] [~] [Configuration] 2: 15 => 15 17:39:43.673 SERIAL » [ACK] (0x06) 17:39:43.674 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 15 17:39:43.675 CNTRLR « [Node 027] parameter #2 has value: 15 17:39:43.675 CNTRLR » [Node 027] querying parameter #3 value... 17:39:43.679 SERIAL » 0x010a00131b0370050325923f (12 bytes) 17:39:43.679 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 146 └─[ConfigurationCCGet] parameter #: 3 17:39:43.683 SERIAL « [ACK] (0x06) 17:39:43.690 SERIAL « 0x0104011301e8 (6 bytes) 17:39:43.691 SERIAL » [ACK] (0x06) 17:39:43.692 DRIVER « [RES] [SendData] was sent: true 17:39:43.704 SERIAL « 0x01070013920000027b (9 bytes) 17:39:43.705 SERIAL » [ACK] (0x06) 17:39:43.705 DRIVER « [REQ] [SendData] callback id: 146 transmit status: OK 17:39:43.724 SERIAL « 0x010b0004001b0570060301019b (13 bytes) 17:39:43.730 CNTRLR [Node 027] [~] [Configuration] 3: 1 => 1 17:39:43.731 SERIAL » [ACK] (0x06) 17:39:43.732 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 1 17:39:43.733 CNTRLR « [Node 027] parameter #3 has value: 1 17:39:43.733 CNTRLR » [Node 027] querying parameter #4 value... 17:39:43.737 SERIAL » 0x010a00131b03700504259339 (12 bytes) 17:39:43.737 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 147 └─[ConfigurationCCGet] parameter #: 4 17:39:43.739 SERIAL « [ACK] (0x06) 17:39:43.745 SERIAL « 0x0104011301e8 (6 bytes) 17:39:43.745 SERIAL » [ACK] (0x06) 17:39:43.746 DRIVER « [RES] [SendData] was sent: true 17:39:43.762 SERIAL « 0x01070013930000027a (9 bytes) 17:39:43.762 SERIAL » [ACK] (0x06) 17:39:43.763 DRIVER « [REQ] [SendData] callback id: 147 transmit status: OK 17:39:43.773 SERIAL « 0x010b0004001b0570060401029f (13 bytes) 17:39:43.778 CNTRLR [Node 027] [~] [Configuration] 4: 2 => 2 17:39:43.779 SERIAL » [ACK] (0x06) 17:39:43.779 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 1 value: 2 17:39:43.781 CNTRLR « [Node 027] parameter #4 has value: 2 17:39:43.781 CNTRLR » [Node 027] querying parameter #6 value... 17:39:43.785 SERIAL » 0x010a00131b0370050625943c (12 bytes) 17:39:43.785 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 148 └─[ConfigurationCCGet] parameter #: 6 17:39:43.788 SERIAL « [ACK] (0x06) 17:39:43.793 SERIAL « 0x0104011301e8 (6 bytes) 17:39:43.794 SERIAL » [ACK] (0x06) 17:39:43.794 DRIVER « [RES] [SendData] was sent: true 17:39:43.810 SERIAL « 0x01070013940000027d (9 bytes) 17:39:43.811 SERIAL » [ACK] (0x06) 17:39:43.811 DRIVER « [REQ] [SendData] callback id: 148 transmit status: OK 17:39:43.821 SERIAL « 0x010c0004001b0670060602001e86 (14 bytes) 17:39:43.826 CNTRLR [Node 027] [~] [Configuration] 6: 30 => 30 17:39:43.827 SERIAL » [ACK] (0x06) 17:39:43.828 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 2 value: 30 17:39:43.831 CNTRLR « [Node 027] parameter #6 has value: 30 17:39:43.832 CNTRLR » [Node 027] querying parameter #8 value... 17:39:43.835 SERIAL » 0x010a00131b03700508259533 (12 bytes) 17:39:43.836 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 149 └─[ConfigurationCCGet] parameter #: 8 17:39:43.838 SERIAL « [ACK] (0x06) 17:39:43.844 SERIAL « 0x0104011301e8 (6 bytes) 17:39:43.844 SERIAL » [ACK] (0x06) 17:39:43.845 DRIVER « [RES] [SendData] was sent: true 17:39:43.861 SERIAL « 0x01070013950000027c (9 bytes) 17:39:43.861 SERIAL » [ACK] (0x06) 17:39:43.861 DRIVER « [REQ] [SendData] callback id: 149 transmit status: OK 17:39:43.872 SERIAL « 0x010b0004001b05700608010091 (13 bytes) 17:39:43.878 CNTRLR [Node 027] [~] [Configuration] 8: 0 => 0 17:39:43.878 SERIAL » [ACK] (0x06) 17:39:43.879 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 0 17:39:43.881 CNTRLR « [Node 027] parameter #8 has value: 0 17:39:43.881 CNTRLR » [Node 027] querying parameter #9 value... 17:39:43.885 SERIAL » 0x010a00131b03700509259631 (12 bytes) 17:39:43.885 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 150 └─[ConfigurationCCGet] parameter #: 9 17:39:43.887 SERIAL « [ACK] (0x06) 17:39:43.893 SERIAL « 0x0104011301e8 (6 bytes) 17:39:43.894 SERIAL » [ACK] (0x06) 17:39:43.894 DRIVER « [RES] [SendData] was sent: true 17:39:43.910 SERIAL « 0x01070013960000027f (9 bytes) 17:39:43.911 SERIAL » [ACK] (0x06) 17:39:43.911 DRIVER « [REQ] [SendData] callback id: 150 transmit status: OK 17:39:43.921 SERIAL « 0x010c0004001b06700609020028bf (14 bytes) 17:39:43.927 CNTRLR [Node 027] [~] [Configuration] 9: 40 => 40 17:39:43.927 SERIAL » [ACK] (0x06) 17:39:43.928 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 2 value: 40 17:39:43.929 CNTRLR « [Node 027] parameter #9 has value: 40 17:39:43.930 CNTRLR » [Node 027] querying parameter #12 value... 17:39:43.933 SERIAL » 0x010a00131b0370050c259735 (12 bytes) 17:39:43.934 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 151 └─[ConfigurationCCGet] parameter #: 12 17:39:43.935 SERIAL « [ACK] (0x06) 17:39:43.942 SERIAL « 0x0104011301e8 (6 bytes) 17:39:43.943 SERIAL » [ACK] (0x06) 17:39:43.943 DRIVER « [RES] [SendData] was sent: true 17:39:43.959 SERIAL « 0x01070013970000037f (9 bytes) 17:39:43.959 SERIAL » [ACK] (0x06) 17:39:43.960 DRIVER « [REQ] [SendData] callback id: 151 transmit status: OK 17:39:43.970 SERIAL « 0x010b0004001b0570060c010095 (13 bytes) 17:39:43.975 CNTRLR [Node 027] [~] [Configuration] 12: 0 => 0 17:39:43.976 SERIAL » [ACK] (0x06) 17:39:43.977 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 1 value: 0 17:39:43.978 CNTRLR « [Node 027] parameter #12 has value: 0 17:39:43.979 CNTRLR » [Node 027] querying parameter #14 value... 17:39:43.982 SERIAL » 0x010a00131b0370050e259838 (12 bytes) 17:39:43.983 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 152 └─[ConfigurationCCGet] parameter #: 14 17:39:43.988 SERIAL « [ACK] (0x06) 17:39:43.996 SERIAL « 0x0104011301e8 (6 bytes) 17:39:43.997 SERIAL » [ACK] (0x06) 17:39:43.997 DRIVER « [RES] [SendData] was sent: true 17:39:44.008 SERIAL « 0x010700139800000370 (9 bytes) 17:39:44.009 SERIAL » [ACK] (0x06) 17:39:44.009 DRIVER « [REQ] [SendData] callback id: 152 transmit status: OK 17:39:44.019 SERIAL « 0x010b0004001b0570060e01ff68 (13 bytes) 17:39:44.024 CNTRLR [Node 027] [~] [Configuration] 14: 255 => 255 17:39:44.025 SERIAL » [ACK] (0x06) 17:39:44.025 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 255 17:39:44.027 CNTRLR « [Node 027] parameter #14 has value: 255 17:39:44.027 CNTRLR » [Node 027] querying parameter #16 value... 17:39:44.030 SERIAL » 0x010a00131b03700510259927 (12 bytes) 17:39:44.031 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 153 └─[ConfigurationCCGet] parameter #: 16 17:39:44.033 SERIAL « [ACK] (0x06) 17:39:44.039 SERIAL « 0x0104011301e8 (6 bytes) 17:39:44.039 SERIAL » [ACK] (0x06) 17:39:44.039 DRIVER « [RES] [SendData] was sent: true 17:39:44.056 SERIAL « 0x010700139900000270 (9 bytes) 17:39:44.056 SERIAL » [ACK] (0x06) 17:39:44.056 DRIVER « [REQ] [SendData] callback id: 153 transmit status: OK 17:39:44.067 SERIAL « 0x010b0004001b05700610010089 (13 bytes) 17:39:44.072 CNTRLR [Node 027] [~] [Configuration] 16: 0 => 0 17:39:44.072 SERIAL » [ACK] (0x06) 17:39:44.073 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 0 17:39:44.074 CNTRLR « [Node 027] parameter #16 has value: 0 17:39:44.077 CNTRLR » [Node 027] querying parameter #20 value... 17:39:44.081 SERIAL » 0x010a00131b03700514259a20 (12 bytes) 17:39:44.081 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 154 └─[ConfigurationCCGet] parameter #: 20 17:39:44.083 SERIAL « [ACK] (0x06) 17:39:44.089 SERIAL « 0x0104011301e8 (6 bytes) 17:39:44.090 SERIAL » [ACK] (0x06) 17:39:44.090 DRIVER « [RES] [SendData] was sent: true 17:39:44.106 SERIAL « 0x010700139a00000273 (9 bytes) 17:39:44.107 SERIAL » [ACK] (0x06) 17:39:44.107 DRIVER « [REQ] [SendData] callback id: 154 transmit status: OK 17:39:44.117 SERIAL « 0x010b0004001b05700614010f82 (13 bytes) 17:39:44.125 CNTRLR [Node 027] [~] [Configuration] 20: 15 => 15 17:39:44.126 SERIAL » [ACK] (0x06) 17:39:44.127 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 15 17:39:44.128 CNTRLR « [Node 027] parameter #20 has value: 15 17:39:44.129 CNTRLR » [Node 027] querying parameter #22 value... 17:39:44.133 SERIAL » 0x010a00131b03700516259b23 (12 bytes) 17:39:44.134 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 155 └─[ConfigurationCCGet] parameter #: 22 17:39:44.136 SERIAL « [ACK] (0x06) 17:39:44.144 SERIAL « 0x0104011301e8 (6 bytes) 17:39:44.145 SERIAL » [ACK] (0x06) 17:39:44.146 DRIVER « [RES] [SendData] was sent: true 17:39:44.159 SERIAL « 0x010700139b00000272 (9 bytes) 17:39:44.160 SERIAL » [ACK] (0x06) 17:39:44.160 DRIVER « [REQ] [SendData] callback id: 155 transmit status: OK 17:39:44.170 SERIAL « 0x010c0004001b0670061602001e96 (14 bytes) 17:39:44.177 CNTRLR [Node 027] [~] [Configuration] 22: 30 => 30 17:39:44.178 SERIAL » [ACK] (0x06) 17:39:44.179 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 30 17:39:44.181 CNTRLR « [Node 027] parameter #22 has value: 30 17:39:44.181 CNTRLR » [Node 027] querying parameter #24 value... 17:39:44.186 SERIAL » 0x010a00131b03700518259c2a (12 bytes) 17:39:44.187 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 156 └─[ConfigurationCCGet] parameter #: 24 17:39:44.189 SERIAL « [ACK] (0x06) 17:39:44.195 SERIAL « 0x0104011301e8 (6 bytes) 17:39:44.195 SERIAL » [ACK] (0x06) 17:39:44.196 DRIVER « [RES] [SendData] was sent: true 17:39:44.211 SERIAL « 0x010c00040003063105042208e60e (14 bytes) 17:39:44.212 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:39:44.212 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 106.9 => 227.8 [Endpoint 0] 17:39:44.213 SERIAL » [ACK] (0x06) 17:39:44.213 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 227.8 17:39:44.230 SERIAL « 0x010700139c00000473 (9 bytes) 17:39:44.231 SERIAL » [ACK] (0x06) 17:39:44.231 DRIVER « [REQ] [SendData] callback id: 156 transmit status: OK 17:39:44.241 SERIAL « 0x010b0004001b05700618010081 (13 bytes) 17:39:44.246 CNTRLR [Node 027] [~] [Configuration] 24: 0 => 0 17:39:44.247 SERIAL » [ACK] (0x06) 17:39:44.247 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 24 value size: 1 value: 0 17:39:44.249 CNTRLR « [Node 027] parameter #24 has value: 0 17:39:44.249 CNTRLR » [Node 027] querying parameter #26 value... 17:39:44.252 SERIAL » 0x010a00131b0370051a259d29 (12 bytes) 17:39:44.253 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 157 └─[ConfigurationCCGet] parameter #: 26 17:39:44.254 SERIAL « [ACK] (0x06) 17:39:44.261 SERIAL « 0x0104011301e8 (6 bytes) 17:39:44.261 SERIAL » [ACK] (0x06) 17:39:44.261 DRIVER « [RES] [SendData] was sent: true 17:39:44.278 SERIAL « 0x010700139d00000375 (9 bytes) 17:39:44.278 SERIAL » [ACK] (0x06) 17:39:44.279 DRIVER « [REQ] [SendData] callback id: 157 transmit status: OK 17:39:44.288 SERIAL « 0x010b0004001b0570061a010083 (13 bytes) 17:39:44.293 CNTRLR [Node 027] [~] [Configuration] 26: 0 => 0 17:39:44.294 SERIAL » [ACK] (0x06) 17:39:44.295 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 26 value size: 1 value: 0 17:39:44.296 CNTRLR « [Node 027] parameter #26 has value: 0 17:39:44.296 CNTRLR » [Node 027] querying parameter #40 value... 17:39:44.300 SERIAL » 0x010a00131b03700528259e18 (12 bytes) 17:39:44.300 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 158 └─[ConfigurationCCGet] parameter #: 40 17:39:44.302 SERIAL « [ACK] (0x06) 17:39:44.308 SERIAL « 0x0104011301e8 (6 bytes) 17:39:44.309 SERIAL » [ACK] (0x06) 17:39:44.309 DRIVER « [RES] [SendData] was sent: true 17:39:44.325 SERIAL « 0x010700139e00000277 (9 bytes) 17:39:44.326 SERIAL » [ACK] (0x06) 17:39:44.326 DRIVER « [REQ] [SendData] callback id: 158 transmit status: OK 17:39:44.336 SERIAL « 0x010c0004001b067006280200c87e (14 bytes) 17:39:44.344 CNTRLR [Node 027] [~] [Configuration] 40: 200 => 200 17:39:44.344 SERIAL » [ACK] (0x06) 17:39:44.345 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 2 value: 200 17:39:44.346 CNTRLR « [Node 027] parameter #40 has value: 200 17:39:44.347 CNTRLR » [Node 027] querying parameter #42 value... 17:39:44.350 SERIAL » 0x010a00131b0370052a259f1b (12 bytes) 17:39:44.350 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 159 └─[ConfigurationCCGet] parameter #: 42 17:39:44.352 SERIAL « [ACK] (0x06) 17:39:44.358 SERIAL « 0x0104011301e8 (6 bytes) 17:39:44.359 SERIAL » [ACK] (0x06) 17:39:44.359 DRIVER « [RES] [SendData] was sent: true 17:39:44.375 SERIAL « 0x010700139f00000276 (9 bytes) 17:39:44.376 SERIAL » [ACK] (0x06) 17:39:44.376 DRIVER « [REQ] [SendData] callback id: 159 transmit status: OK 17:39:44.386 SERIAL « 0x010c0004001b0670062a020000b4 (14 bytes) 17:39:44.391 CNTRLR [Node 027] [~] [Configuration] 42: 0 => 0 17:39:44.392 SERIAL » [ACK] (0x06) 17:39:44.393 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 0 17:39:44.394 CNTRLR « [Node 027] parameter #42 has value: 0 17:39:44.394 CNTRLR » [Node 027] querying parameter #60 value... 17:39:44.398 SERIAL » 0x010a00131b0370053c25a032 (12 bytes) 17:39:44.398 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 160 └─[ConfigurationCCGet] parameter #: 60 17:39:44.400 SERIAL « [ACK] (0x06) 17:39:44.406 SERIAL « 0x0104011301e8 (6 bytes) 17:39:44.406 SERIAL » [ACK] (0x06) 17:39:44.407 DRIVER « [RES] [SendData] was sent: true 17:39:44.423 SERIAL « 0x01070013a000000249 (9 bytes) 17:39:44.424 SERIAL » [ACK] (0x06) 17:39:44.424 DRIVER « [REQ] [SendData] callback id: 160 transmit status: OK 17:39:44.434 SERIAL « 0x010b0004001b0570063c010aaf (13 bytes) 17:39:44.439 CNTRLR [Node 027] [~] [Configuration] 60: 10 => 10 17:39:44.440 SERIAL » [ACK] (0x06) 17:39:44.440 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 1 value: 10 17:39:44.442 CNTRLR « [Node 027] parameter #60 has value: 10 17:39:44.442 CNTRLR » [Node 027] querying parameter #62 value... 17:39:44.445 SERIAL » 0x010a00131b0370053e25a131 (12 bytes) 17:39:44.446 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 161 └─[ConfigurationCCGet] parameter #: 62 17:39:44.447 SERIAL « [ACK] (0x06) 17:39:44.454 SERIAL « 0x0104011301e8 (6 bytes) 17:39:44.457 SERIAL » [ACK] (0x06) 17:39:44.458 DRIVER « [RES] [SendData] was sent: true 17:39:44.471 SERIAL « 0x01070013a100000248 (9 bytes) 17:39:44.471 SERIAL » [ACK] (0x06) 17:39:44.472 DRIVER « [REQ] [SendData] callback id: 161 transmit status: OK 17:39:44.482 SERIAL « 0x010c0004001b0670063e02038427 (14 bytes) 17:39:44.487 CNTRLR [Node 027] [~] [Configuration] 62: 900 => 900 17:39:44.488 SERIAL » [ACK] (0x06) 17:39:44.488 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 62 value size: 2 value: 900 17:39:44.490 CNTRLR « [Node 027] parameter #62 has value: 900 17:39:44.490 CNTRLR » [Node 027] querying parameter #64 value... 17:39:44.493 SERIAL » 0x010a00131b0370054025a24c (12 bytes) 17:39:44.494 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 162 └─[ConfigurationCCGet] parameter #: 64 17:39:44.495 SERIAL « [ACK] (0x06) 17:39:44.502 SERIAL « 0x0104011301e8 (6 bytes) 17:39:44.502 SERIAL » [ACK] (0x06) 17:39:44.503 DRIVER « [RES] [SendData] was sent: true 17:39:44.519 SERIAL « 0x01070013a20000034a (9 bytes) 17:39:44.519 SERIAL » [ACK] (0x06) 17:39:44.519 DRIVER « [REQ] [SendData] callback id: 162 transmit status: OK 17:39:44.530 SERIAL « 0x010c0004001b06700640020000de (14 bytes) 17:39:44.535 CNTRLR [Node 027] [~] [Configuration] 64: 0 => 0 17:39:44.536 SERIAL » [ACK] (0x06) 17:39:44.536 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 64 value size: 2 value: 0 17:39:44.538 CNTRLR « [Node 027] parameter #64 has value: 0 17:39:44.538 CNTRLR » [Node 027] querying parameter #66 value... 17:39:44.541 SERIAL » 0x010a00131b0370054225a34f (12 bytes) 17:39:44.542 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 163 └─[ConfigurationCCGet] parameter #: 66 17:39:44.543 SERIAL « [ACK] (0x06) 17:39:44.550 SERIAL « 0x0104011301e8 (6 bytes) 17:39:44.550 SERIAL » [ACK] (0x06) 17:39:44.551 DRIVER « [RES] [SendData] was sent: true 17:39:44.567 SERIAL « 0x01070013a30000034b (9 bytes) 17:39:44.567 SERIAL » [ACK] (0x06) 17:39:44.568 DRIVER « [REQ] [SendData] callback id: 163 transmit status: OK 17:39:44.578 SERIAL « 0x010c0004001b06700642020000dc (14 bytes) 17:39:44.583 CNTRLR [Node 027] [~] [Configuration] 66: 0 => 0 17:39:44.584 SERIAL » [ACK] (0x06) 17:39:44.584 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 66 value size: 2 value: 0 17:39:44.590 CNTRLR « [Node 027] parameter #66 has value: 0 17:39:44.590 CNTRLR » [Node 027] querying parameter #80 value... 17:39:44.594 SERIAL » 0x010a00131b0370055025a45a (12 bytes) 17:39:44.594 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 164 └─[ConfigurationCCGet] parameter #: 80 17:39:44.596 SERIAL « [ACK] (0x06) 17:39:44.602 SERIAL « 0x0104011301e8 (6 bytes) 17:39:44.603 SERIAL » [ACK] (0x06) 17:39:44.603 DRIVER « [RES] [SendData] was sent: true 17:39:44.619 SERIAL « 0x01070013a40000024d (9 bytes) 17:39:44.620 SERIAL » [ACK] (0x06) 17:39:44.620 DRIVER « [REQ] [SendData] callback id: 164 transmit status: OK 17:39:44.630 SERIAL « 0x010b0004001b057006500100c9 (13 bytes) 17:39:44.635 CNTRLR [Node 027] [~] [Configuration] 80: 0 => 0 17:39:44.636 SERIAL » [ACK] (0x06) 17:39:44.637 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 80 value size: 1 value: 0 17:39:44.638 CNTRLR « [Node 027] parameter #80 has value: 0 17:39:44.638 CNTRLR » [Node 027] querying parameter #81 value... 17:39:44.642 SERIAL » 0x010a00131b0370055125a55a (12 bytes) 17:39:44.642 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 165 └─[ConfigurationCCGet] parameter #: 81 17:39:44.644 SERIAL « [ACK] (0x06) 17:39:44.651 SERIAL « 0x0104011301e8 (6 bytes) 17:39:44.651 SERIAL » [ACK] (0x06) 17:39:44.652 DRIVER « [RES] [SendData] was sent: true 17:39:44.667 SERIAL « 0x01070013a50000034d (9 bytes) 17:39:44.668 SERIAL » [ACK] (0x06) 17:39:44.668 DRIVER « [REQ] [SendData] callback id: 165 transmit status: OK 17:39:44.678 SERIAL « 0x010b0004001b057006510132fa (13 bytes) 17:39:44.683 CNTRLR [Node 027] [~] [Configuration] 81: 50 => 50 17:39:44.684 SERIAL » [ACK] (0x06) 17:39:44.685 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 81 value size: 1 value: 50 17:39:44.686 CNTRLR « [Node 027] parameter #81 has value: 50 17:39:44.686 CNTRLR » [Node 027] querying parameter #82 value... 17:39:44.691 SERIAL » 0x010a00131b0370055225a65a (12 bytes) 17:39:44.691 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 166 └─[ConfigurationCCGet] parameter #: 82 17:39:44.693 SERIAL « [ACK] (0x06) 17:39:44.699 SERIAL « 0x0104011301e8 (6 bytes) 17:39:44.700 SERIAL » [ACK] (0x06) 17:39:44.700 DRIVER « [RES] [SendData] was sent: true 17:39:44.726 SERIAL « 0x01070013a60000024f (9 bytes) 17:39:44.727 SERIAL » [ACK] (0x06) 17:39:44.728 DRIVER « [REQ] [SendData] callback id: 166 transmit status: OK 17:39:44.735 SERIAL « 0x010c0004001b06700652020064a8 (14 bytes) 17:39:44.742 CNTRLR [Node 027] [~] [Configuration] 82: 100 => 100 17:39:44.743 SERIAL » [ACK] (0x06) 17:39:44.752 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 82 value size: 2 value: 100 17:39:44.756 CNTRLR « [Node 027] parameter #82 has value: 100 17:39:44.756 CNTRLR » [Node 027] querying parameter #83 value... 17:39:44.770 SERIAL » 0x010a00131b0370055325a75a (12 bytes) 17:39:44.771 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 167 └─[ConfigurationCCGet] parameter #: 83 17:39:44.775 SERIAL « [ACK] (0x06) 17:39:44.782 SERIAL « 0x0104011301e8 (6 bytes) 17:39:44.783 SERIAL » [ACK] (0x06) 17:39:44.784 DRIVER « [RES] [SendData] was sent: true 17:39:44.796 SERIAL « 0x01070013a70000024e (9 bytes) 17:39:44.796 SERIAL » [ACK] (0x06) 17:39:44.797 DRIVER « [REQ] [SendData] callback id: 167 transmit status: OK 17:39:44.807 SERIAL « 0x010c0004001b067006530203e826 (14 bytes) 17:39:44.812 CNTRLR [Node 027] [~] [Configuration] 83: 1000 => 1000 17:39:44.813 SERIAL » [ACK] (0x06) 17:39:44.814 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 83 value size: 2 value: 1000 17:39:44.815 CNTRLR « [Node 027] parameter #83 has value: 1000 17:39:44.815 CNTRLR » [Node 027] querying parameter #86 value... 17:39:44.819 SERIAL » 0x010a00131b0370055625a850 (12 bytes) 17:39:44.819 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 168 └─[ConfigurationCCGet] parameter #: 86 17:39:44.821 SERIAL « [ACK] (0x06) 17:39:44.827 SERIAL « 0x0104011301e8 (6 bytes) 17:39:44.828 SERIAL » [ACK] (0x06) 17:39:44.828 DRIVER « [RES] [SendData] was sent: true 17:39:44.844 SERIAL « 0x01070013a800000241 (9 bytes) 17:39:44.845 SERIAL » [ACK] (0x06) 17:39:44.845 DRIVER « [REQ] [SendData] callback id: 168 transmit status: OK 17:39:44.855 SERIAL « 0x010b0004001b057006560112dd (13 bytes) 17:39:44.860 CNTRLR [Node 027] [~] [Configuration] 86: 18 => 18 17:39:44.861 SERIAL » [ACK] (0x06) 17:39:44.861 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 86 value size: 1 value: 18 17:39:44.863 CNTRLR « [Node 027] parameter #86 has value: 18 17:39:44.863 CNTRLR » [Node 027] querying parameter #87 value... 17:39:44.866 SERIAL » 0x010a00131b0370055725a950 (12 bytes) 17:39:44.867 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 169 └─[ConfigurationCCGet] parameter #: 87 17:39:44.869 SERIAL « [ACK] (0x06) 17:39:44.875 SERIAL « 0x0104011301e8 (6 bytes) 17:39:44.875 SERIAL » [ACK] (0x06) 17:39:44.876 DRIVER « [RES] [SendData] was sent: true 17:39:44.892 SERIAL « 0x01070013a900000240 (9 bytes) 17:39:44.893 SERIAL » [ACK] (0x06) 17:39:44.893 DRIVER « [REQ] [SendData] callback id: 169 transmit status: OK 17:39:44.903 SERIAL « 0x010b0004001b05700657011cd2 (13 bytes) 17:39:44.909 CNTRLR [Node 027] [~] [Configuration] 87: 28 => 28 17:39:44.910 SERIAL » [ACK] (0x06) 17:39:44.911 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 87 value size: 1 value: 28 17:39:44.915 CNTRLR « [Node 027] parameter #87 has value: 28 17:39:44.916 CNTRLR » [Node 027] querying parameter #89 value... 17:39:44.927 SERIAL » 0x010a00131b0370055925aa5d (12 bytes) 17:39:44.927 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 170 └─[ConfigurationCCGet] parameter #: 89 17:39:44.931 SERIAL « [ACK] (0x06) 17:39:44.936 SERIAL « 0x0104011301e8 (6 bytes) 17:39:44.936 SERIAL » [ACK] (0x06) 17:39:44.937 DRIVER « [RES] [SendData] was sent: true 17:39:44.953 SERIAL « 0x01070013aa00000243 (9 bytes) 17:39:44.954 SERIAL » [ACK] (0x06) 17:39:44.954 DRIVER « [REQ] [SendData] callback id: 170 transmit status: OK 17:39:44.964 SERIAL « 0x010b0004001b057006590101c1 (13 bytes) 17:39:44.972 CNTRLR [Node 027] [~] [Configuration] 89: 1 => 1 17:39:44.973 SERIAL » [ACK] (0x06) 17:39:44.974 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 89 value size: 1 value: 1 17:39:44.975 CNTRLR « [Node 027] parameter #89 has value: 1 17:39:44.976 CNTRLR [Node 027] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:39:45.025 CNTRLR [Node 027] AlarmSensorCC: doing a partial interview... 17:39:45.026 CNTRLR » [Node 027] querying current value for General Purpose... 17:39:45.030 SERIAL » 0x010a00131b039c010025abed (12 bytes) 17:39:45.030 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 171 └─[AlarmSensorCCGet] sensor type: General Purpose 17:39:45.032 SERIAL « [ACK] (0x06) 17:39:45.038 SERIAL « 0x0104011301e8 (6 bytes) 17:39:45.038 SERIAL » [ACK] (0x06) 17:39:45.039 DRIVER « [RES] [SendData] was sent: true 17:39:45.055 SERIAL « 0x01070013ab00000242 (9 bytes) 17:39:45.056 SERIAL » [ACK] (0x06) 17:39:45.056 DRIVER « [REQ] [SendData] callback id: 171 transmit status: OK 17:39:45.066 SERIAL « 0x010d0004001b079c021b000000006f (15 bytes) 17:39:45.067 CNTRLR [Node 027] [~] [Alarm Sensor] state[0]: true => false [Endpoint 0] 17:39:45.068 CNTRLR [Node 027] [~] [Alarm Sensor] severity[0]: undefined => undefined [Endpoint 0] 17:39:45.069 CNTRLR [Node 027] [~] [Alarm Sensor] duration[0]: undefined => undefined [Endpoint 0] 17:39:45.069 SERIAL » [ACK] (0x06) 17:39:45.070 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: false 17:39:45.071 CNTRLR « [Node 027] received current value for General Purpose: state: false 17:39:45.072 CNTRLR [Node 027] [~] [Alarm Sensor] interviewComplete: true [Endpoint 0] [internal] => true 17:39:45.072 CNTRLR [Node 027] MultiChannelAssociationCC: doing a partial interview... 17:39:45.072 CNTRLR » [Node 027] querying multi channel association group #1... 17:39:45.076 SERIAL » 0x010a00131b038e020125acfa (12 bytes) 17:39:45.077 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 172 └─[MultiChannelAssociationCCGet] group id: 1 17:39:45.079 SERIAL « [ACK] (0x06) 17:39:45.085 SERIAL « 0x0104011301e8 (6 bytes) 17:39:45.085 SERIAL » [ACK] (0x06) 17:39:45.086 DRIVER « [RES] [SendData] was sent: true 17:39:45.101 SERIAL « 0x01070013ac00000245 (9 bytes) 17:39:45.102 SERIAL » [ACK] (0x06) 17:39:45.102 DRIVER « [REQ] [SendData] callback id: 172 transmit status: OK 17:39:45.113 SERIAL « 0x010c0004001b068e030105000162 (14 bytes) 17:39:45.113 SERIAL » [ACK] (0x06) 17:39:45.114 CNTRLR [Node 027] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 17:39:45.115 CNTRLR [Node 027] [~] [Multi Channel Association] nodeIds[1]: 1 => 1 17:39:45.116 CNTRLR [Node 027] [~] [Multi Channel Association] endpoints[1]: => 17:39:45.117 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: 1 endpoints: 17:39:45.118 CNTRLR « [Node 027] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 17:39:45.118 CNTRLR » [Node 027] querying multi channel association group #2... 17:39:45.122 SERIAL » 0x010a00131b038e020225adf8 (12 bytes) 17:39:45.123 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 173 └─[MultiChannelAssociationCCGet] group id: 2 17:39:45.124 SERIAL « [ACK] (0x06) 17:39:45.131 SERIAL « 0x0104011301e8 (6 bytes) 17:39:45.131 SERIAL » [ACK] (0x06) 17:39:45.132 DRIVER « [RES] [SendData] was sent: true 17:39:45.148 SERIAL « 0x01070013ad00000345 (9 bytes) 17:39:45.148 SERIAL » [ACK] (0x06) 17:39:45.149 DRIVER « [REQ] [SendData] callback id: 173 transmit status: OK 17:39:45.159 SERIAL « 0x010c0004001b068e030205000161 (14 bytes) 17:39:45.159 SERIAL » [ACK] (0x06) 17:39:45.160 CNTRLR [Node 027] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 17:39:45.161 CNTRLR [Node 027] [~] [Multi Channel Association] nodeIds[2]: 1 => 1 17:39:45.162 CNTRLR [Node 027] [~] [Multi Channel Association] endpoints[2]: => 17:39:45.163 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: 1 endpoints: 17:39:45.165 CNTRLR « [Node 027] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 17:39:45.165 CNTRLR » [Node 027] querying additional non-multi-channel association groups... 17:39:45.165 CNTRLR » [Node 027] querying association group #3... 17:39:45.169 SERIAL » 0x010a00131b0385020325aef1 (12 bytes) 17:39:45.169 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 174 └─[AssociationCCGet] group id: 3 17:39:45.172 SERIAL « [ACK] (0x06) 17:39:45.178 SERIAL « 0x0104011301e8 (6 bytes) 17:39:45.178 SERIAL » [ACK] (0x06) 17:39:45.181 DRIVER « [RES] [SendData] was sent: true 17:39:45.194 SERIAL « 0x01070013ae00000247 (9 bytes) 17:39:45.195 SERIAL » [ACK] (0x06) 17:39:45.195 DRIVER « [REQ] [SendData] callback id: 174 transmit status: OK 17:39:45.206 SERIAL « 0x010c0004001b068503030100016f (14 bytes) 17:39:45.206 SERIAL » [ACK] (0x06) 17:39:45.207 CNTRLR [Node 027] [~] [Association] maxNodes[3]: 1 => 1 [internal] 17:39:45.207 CNTRLR [Node 027] [~] [Association] nodeIds[3]: 1 => 1 [internal] 17:39:45.208 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 17:39:45.209 CNTRLR « [Node 027] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 17:39:45.210 CNTRLR [Node 027] [~] [Association] hasLifeline: true => true [internal] 17:39:45.210 CNTRLR [Node 027] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:39:45.242 CNTRLR [Node 027] Interview stage completed: CommandClasses 17:39:45.243 CNTRLR [Node 027] Interview stage completed: OverwriteConfig 17:39:45.243 CNTRLR » [Node 027] requesting node neighbors... 17:39:45.246 SERIAL » 0x010700801b00000063 (9 bytes) 17:39:45.247 DRIVER » [Node 027] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:39:45.248 SERIAL « [ACK] (0x06) 17:39:45.251 SERIAL « 0x012001800530c4030000000000000000000000000000000000000000000000000 (34 bytes) 0ac 17:39:45.255 SERIAL » [ACK] (0x06) 17:39:45.255 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 13, 14, 19, 23, 24, 25, 26 17:39:45.258 CNTRLR « [Node 027] node neighbors received: 1, 3, 13, 14, 19, 23, 24, 25, 26 17:39:45.258 CNTRLR [Node 027] Interview stage completed: Neighbors 17:39:45.258 CNTRLR [Node 027] Interview completed 17:39:46.260 CNTRLR » [Node 027] Sending node back to sleep... 17:39:46.268 SERIAL » 0x010900131b02840825affa (11 bytes) 17:39:46.269 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 175 └─[WakeUpCCNoMoreInformation] 17:39:46.271 SERIAL « [ACK] (0x06) 17:39:46.277 SERIAL « 0x0104011301e8 (6 bytes) 17:39:46.278 SERIAL » [ACK] (0x06) 17:39:46.279 DRIVER « [RES] [SendData] was sent: true 17:39:46.294 SERIAL « 0x01070013af00000246 (9 bytes) 17:39:46.295 SERIAL » [ACK] (0x06) 17:39:46.296 DRIVER « [REQ] [SendData] callback id: 175 transmit status: OK 17:39:46.300 CNTRLR [Node 027] The node is now asleep. 17:39:47.969 SERIAL « 0x010c00040003063105042203c724 (14 bytes) 17:39:47.971 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:39:47.973 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 227.8 => 96.7 [Endpoint 0] 17:39:47.974 SERIAL » [ACK] (0x06) 17:39:47.976 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 96.7 17:39:48.969 SERIAL « 0x010c00040003063105042208c62e (14 bytes) 17:39:48.970 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:39:48.970 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 96.7 => 224.6 [Endpoint 0] 17:39:48.971 SERIAL » [ACK] (0x06) 17:39:48.972 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 224.6 17:39:50.969 SERIAL « 0x010c000400030631050422049773 (14 bytes) 17:39:50.970 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:39:50.971 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 224.6 => 117.5 [Endpoint 0] 17:39:50.971 SERIAL » [ACK] (0x06) 17:39:50.972 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 117.5 17:39:54.970 SERIAL « 0x010c0004000306310504220a06ec (14 bytes) 17:39:54.975 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:39:54.976 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 117.5 => 256.6 [Endpoint 0] 17:39:54.977 SERIAL » [ACK] (0x06) 17:39:54.995 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 256.6 17:39:57.388 SERIAL « 0x01080004001102840763 (10 bytes) 17:39:57.388 SERIAL » [ACK] (0x06) 17:39:57.389 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:39:57.390 CNTRLR « [Node 017] received wakeup notification 17:39:57.390 CNTRLR [Node 017] The node is now awake. 17:39:57.393 SERIAL » 0x010900131102800225b0e1 (11 bytes) 17:39:57.394 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 176 └─[BatteryCCGet] 17:39:57.395 SERIAL « [ACK] (0x06) 17:39:57.401 SERIAL « 0x0104011301e8 (6 bytes) 17:39:57.402 SERIAL » [ACK] (0x06) 17:39:57.402 DRIVER « [RES] [SendData] was sent: true 17:39:57.431 SERIAL « 0x01070013b00000045f (9 bytes) 17:39:57.431 SERIAL » [ACK] (0x06) 17:39:57.432 DRIVER « [REQ] [SendData] callback id: 176 transmit status: OK 17:39:57.441 SERIAL « 0x0109000400110380036407 (11 bytes) 17:39:57.442 CNTRLR [Node 017] [~] [Battery] level: 100 => 100 [Endpoint 0] 17:39:57.443 CNTRLR [Node 017] [~] [Battery] isLow: false => false [Endpoint 0] 17:39:57.443 SERIAL » [ACK] (0x06) 17:39:57.444 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 17:39:57.446 CNTRLR « [Node 017] received response for battery information: level: 100 17:39:57.446 CNTRLR [Node 017] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:39:57.491 CNTRLR [Node 017] WakeUpCC: doing a partial interview... 17:39:57.491 CNTRLR » [Node 017] retrieving wakeup interval from the device... 17:39:57.500 SERIAL » 0x010900131102840525b1e3 (11 bytes) 17:39:57.500 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 177 └─[WakeUpCCIntervalGet] 17:39:57.505 SERIAL « [ACK] (0x06) 17:39:57.508 SERIAL « 0x0104011301e8 (6 bytes) 17:39:57.509 SERIAL » [ACK] (0x06) 17:39:57.510 DRIVER « [RES] [SendData] was sent: true 17:39:57.525 SERIAL « 0x01070013b100000258 (9 bytes) 17:39:57.527 SERIAL » [ACK] (0x06) 17:39:57.528 DRIVER « [REQ] [SendData] callback id: 177 transmit status: OK 17:39:57.536 SERIAL « 0x010c0004001106840600038401e4 (14 bytes) 17:39:57.537 CNTRLR [Node 017] [~] [Wake Up] wakeUpInterval: 900 => 900 [Endpoint 0] 17:39:57.538 CNTRLR [Node 017] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 17:39:57.538 SERIAL » [ACK] (0x06) 17:39:57.539 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 900 seconds controller node id: 1 17:39:57.540 CNTRLR « [Node 017] received wakeup configuration: wakeup interval: 900 seconds controller node: 1 17:39:57.541 CNTRLR [Node 017] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 17:39:57.541 CNTRLR [Node 017] AssociationCC: doing a partial interview... 17:39:57.541 CNTRLR [Node 017] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 17:39:57.542 CNTRLR [Node 017] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 17:39:57.542 CNTRLR [Node 017] BasicCC: doing a partial interview... 17:39:57.542 CNTRLR » [Node 017] querying Basic CC state... 17:39:57.547 SERIAL » 0x010900131102200225b243 (11 bytes) 17:39:57.547 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 178 └─[BasicCCGet] 17:39:57.549 SERIAL « [ACK] (0x06) 17:39:57.555 SERIAL « 0x0104011301e8 (6 bytes) 17:39:57.556 SERIAL » [ACK] (0x06) 17:39:57.556 DRIVER « [RES] [SendData] was sent: true 17:39:57.572 SERIAL « 0x01070013b20000025b (9 bytes) 17:39:57.573 SERIAL » [ACK] (0x06) 17:39:57.573 DRIVER « [REQ] [SendData] callback id: 178 transmit status: OK 17:39:57.583 SERIAL « 0x01090004001103200300c3 (11 bytes) 17:39:57.583 SERIAL » [ACK] (0x06) 17:39:57.584 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BasicCCReport] current value: 0 17:39:57.585 CNTRLR « [Node 017] received Basic CC state: current value: 0 17:39:57.586 CNTRLR [Node 017] [~] [Basic] interviewComplete: true => true [Endpoint 0] [internal] 17:39:57.586 CNTRLR [Node 017] BinarySensorCC: doing a partial interview... 17:39:57.586 CNTRLR » [Node 017] querying current value... 17:39:57.594 SERIAL » 0x010900131102300225b352 (11 bytes) 17:39:57.595 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 179 └─[BinarySensorCCGet] type: Any 17:39:57.597 SERIAL « [ACK] (0x06) 17:39:57.603 SERIAL « 0x0104011301e8 (6 bytes) 17:39:57.603 SERIAL » [ACK] (0x06) 17:39:57.604 DRIVER « [RES] [SendData] was sent: true 17:39:57.620 SERIAL « 0x01070013b30000025a (9 bytes) 17:39:57.620 SERIAL » [ACK] (0x06) 17:39:57.621 DRIVER « [REQ] [SendData] callback id: 179 transmit status: OK 17:39:57.630 SERIAL « 0x01090004001103300300d3 (11 bytes) 17:39:57.631 CNTRLR [Node 017] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:39:57.632 CNTRLR [Node 017] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:39:57.632 SERIAL » [ACK] (0x06) 17:39:57.633 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:39:57.635 CNTRLR « [Node 017] received current value: false 17:39:57.635 CNTRLR [Node 017] [~] [Binary Sensor] interviewComplete: true [Endpoint 0] [internal] => true 17:39:57.635 CNTRLR [Node 017] MultilevelSensorCC: doing a partial interview... 17:39:57.636 CNTRLR » [Node 017] querying Air temperature sensor reading... 17:39:57.640 SERIAL » 0x010b001311043104010025b457 (13 bytes) 17:39:57.640 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 180 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 17:39:57.642 SERIAL « [ACK] (0x06) 17:39:57.648 SERIAL « 0x0104011301e8 (6 bytes) 17:39:57.648 SERIAL » [ACK] (0x06) 17:39:57.649 DRIVER « [RES] [SendData] was sent: true 17:39:57.665 SERIAL « 0x01070013b40000025d (9 bytes) 17:39:57.666 SERIAL » [ACK] (0x06) 17:39:57.666 DRIVER « [REQ] [SendData] callback id: 180 transmit status: OK 17:39:57.677 SERIAL « 0x010c00040011063105012200ae59 (14 bytes) 17:39:57.678 CNTRLR [Node 017] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 17:39:57.678 CNTRLR [Node 017] [~] [Multilevel Sensor] Air temperature: 17.5 => 17.4 [Endpoint 0] 17:39:57.679 SERIAL » [ACK] (0x06) 17:39:57.679 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 17.4 17:39:57.681 CNTRLR « [Node 017] received current Air temperature sensor reading: 17.4 °C 17:39:57.681 CNTRLR » [Node 017] querying Illuminance sensor reading... 17:39:57.685 SERIAL » 0x010b001311043104030825b55c (13 bytes) 17:39:57.685 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 181 └─[MultilevelSensorCCGet] sensor type: Illuminance scale: Lux 17:39:57.687 SERIAL « [ACK] (0x06) 17:39:57.725 SERIAL « 0x0104011301e8 (6 bytes) 17:39:57.725 SERIAL » [ACK] (0x06) 17:39:57.726 DRIVER « [RES] [SendData] was sent: true 17:39:57.728 SERIAL « 0x01070013b50000025c (9 bytes) 17:39:57.729 SERIAL » [ACK] (0x06) 17:39:57.729 DRIVER « [REQ] [SendData] callback id: 181 transmit status: OK 17:39:57.731 SERIAL « 0x010c00040011063105030a0001dc (14 bytes) 17:39:57.732 CNTRLR [Node 017] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 17:39:57.733 CNTRLR [Node 017] [~] [Multilevel Sensor] Illuminance: 110 => 1 [Endpoint 0] 17:39:57.733 SERIAL » [ACK] (0x06) 17:39:57.734 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 1 17:39:57.736 CNTRLR « [Node 017] received current Illuminance sensor reading: 1 Lux 17:39:57.736 CNTRLR [Node 017] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 17:39:57.736 CNTRLR [Node 017] ConfigurationCC: Loading configuration parameters from device confi g 17:39:57.743 CNTRLR [Node 017] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 17:39:57.744 CNTRLR [Node 017] [Configuration] 1: metadata updated 17:39:57.745 CNTRLR [Node 017] [Configuration] 2: metadata updated 17:39:57.747 CNTRLR [Node 017] [Configuration] 3: metadata updated 17:39:57.748 CNTRLR [Node 017] [Configuration] 4: metadata updated 17:39:57.750 CNTRLR [Node 017] [Configuration] 6: metadata updated 17:39:57.751 CNTRLR [Node 017] [Configuration] 8: metadata updated 17:39:57.753 CNTRLR [Node 017] [Configuration] 9: metadata updated 17:39:57.754 CNTRLR [Node 017] [Configuration] 12: metadata updated 17:39:57.756 CNTRLR [Node 017] [Configuration] 14: metadata updated 17:39:57.757 CNTRLR [Node 017] [Configuration] 16: metadata updated 17:39:57.759 CNTRLR [Node 017] [Configuration] 20: metadata updated 17:39:57.760 CNTRLR [Node 017] [Configuration] 22: metadata updated 17:39:57.764 CNTRLR [Node 017] [Configuration] 24: metadata updated 17:39:57.766 CNTRLR [Node 017] [Configuration] 26: metadata updated 17:39:57.767 CNTRLR [Node 017] [Configuration] 40: metadata updated 17:39:57.769 CNTRLR [Node 017] [Configuration] 42: metadata updated 17:39:57.770 CNTRLR [Node 017] [Configuration] 60: metadata updated 17:39:57.773 CNTRLR [Node 017] [Configuration] 62: metadata updated 17:39:57.775 CNTRLR [Node 017] [Configuration] 64: metadata updated 17:39:57.776 CNTRLR [Node 017] [Configuration] 66: metadata updated 17:39:57.778 CNTRLR [Node 017] [Configuration] 80: metadata updated 17:39:57.779 CNTRLR [Node 017] [Configuration] 81: metadata updated 17:39:57.781 CNTRLR [Node 017] [Configuration] 82: metadata updated 17:39:57.782 CNTRLR [Node 017] [Configuration] 83: metadata updated 17:39:57.784 CNTRLR [Node 017] [Configuration] 86: metadata updated 17:39:57.785 CNTRLR [Node 017] [Configuration] 87: metadata updated 17:39:57.787 CNTRLR [Node 017] [Configuration] 89: metadata updated 17:39:57.788 CNTRLR [Node 017] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 17:39:57.788 CNTRLR » [Node 017] querying parameter #1 value... 17:39:57.792 SERIAL » 0x010a0013110370050125b613 (12 bytes) 17:39:57.793 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 182 └─[ConfigurationCCGet] parameter #: 1 17:39:57.801 SERIAL « [ACK] (0x06) 17:39:57.804 SERIAL « 0x0104011301e8 (6 bytes) 17:39:57.805 SERIAL » [ACK] (0x06) 17:39:57.809 DRIVER « [RES] [SendData] was sent: true 17:39:57.827 SERIAL « 0x01070013b60000035e (9 bytes) 17:39:57.828 SERIAL » [ACK] (0x06) 17:39:57.836 DRIVER « [REQ] [SendData] callback id: 182 transmit status: OK 17:39:57.843 SERIAL « 0x010b0004001105700601010a98 (13 bytes) 17:39:57.850 CNTRLR [Node 017] [~] [Configuration] 1: 10 => 10 17:39:57.851 SERIAL » [ACK] (0x06) 17:39:57.854 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 10 17:39:57.856 CNTRLR « [Node 017] parameter #1 has value: 10 17:39:57.856 CNTRLR » [Node 017] querying parameter #2 value... 17:39:57.862 SERIAL » 0x010a0013110370050225b711 (12 bytes) 17:39:57.863 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 183 └─[ConfigurationCCGet] parameter #: 2 17:39:57.869 SERIAL « [ACK] (0x06) 17:39:57.878 SERIAL « 0x0104011301e8 (6 bytes) 17:39:57.878 SERIAL » [ACK] (0x06) 17:39:57.880 DRIVER « [RES] [SendData] was sent: true 17:39:57.919 SERIAL « 0x01070013b70000035f (9 bytes) 17:39:57.920 SERIAL » [ACK] (0x06) 17:39:57.926 DRIVER « [REQ] [SendData] callback id: 183 transmit status: OK 17:39:57.930 SERIAL « 0x010b0004001105700602010f9e (13 bytes) 17:39:57.938 CNTRLR [Node 017] [~] [Configuration] 2: 15 => 15 17:39:57.939 SERIAL » [ACK] (0x06) 17:39:57.940 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 15 17:39:57.948 CNTRLR « [Node 017] parameter #2 has value: 15 17:39:57.948 CNTRLR » [Node 017] querying parameter #3 value... 17:39:57.953 SERIAL » 0x010a0013110370050325b81f (12 bytes) 17:39:57.954 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 184 └─[ConfigurationCCGet] parameter #: 3 17:39:57.958 SERIAL « [ACK] (0x06) 17:39:57.963 SERIAL « 0x0104011301e8 (6 bytes) 17:39:57.963 SERIAL » [ACK] (0x06) 17:39:57.964 DRIVER « [RES] [SendData] was sent: true 17:39:57.979 SERIAL « 0x01070013b800000251 (9 bytes) 17:39:57.979 SERIAL » [ACK] (0x06) 17:39:57.980 DRIVER « [REQ] [SendData] callback id: 184 transmit status: OK 17:39:57.990 SERIAL « 0x010b0004001105700603010191 (13 bytes) 17:39:57.995 CNTRLR [Node 017] [~] [Configuration] 3: 1 => 1 17:39:57.997 SERIAL » [ACK] (0x06) 17:39:57.998 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 1 17:39:57.999 CNTRLR « [Node 017] parameter #3 has value: 1 17:39:58.000 CNTRLR » [Node 017] querying parameter #4 value... 17:39:58.003 SERIAL » 0x010a0013110370050425b919 (12 bytes) 17:39:58.003 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 185 └─[ConfigurationCCGet] parameter #: 4 17:39:58.012 SERIAL « [ACK] (0x06) 17:39:58.014 SERIAL « 0x0104011301e8 (6 bytes) 17:39:58.015 SERIAL » [ACK] (0x06) 17:39:58.016 DRIVER « [RES] [SendData] was sent: true 17:39:58.029 SERIAL « 0x01070013b900000351 (9 bytes) 17:39:58.029 SERIAL » [ACK] (0x06) 17:39:58.030 DRIVER « [REQ] [SendData] callback id: 185 transmit status: OK 17:39:58.039 SERIAL « 0x010b0004001105700604010295 (13 bytes) 17:39:58.046 CNTRLR [Node 017] [~] [Configuration] 4: 2 => 2 17:39:58.047 SERIAL » [ACK] (0x06) 17:39:58.048 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 1 value: 2 17:39:58.050 CNTRLR « [Node 017] parameter #4 has value: 2 17:39:58.050 CNTRLR » [Node 017] querying parameter #6 value... 17:39:58.055 SERIAL » 0x010a0013110370050625ba18 (12 bytes) 17:39:58.056 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 186 └─[ConfigurationCCGet] parameter #: 6 17:39:58.059 SERIAL « [ACK] (0x06) 17:39:58.065 SERIAL « 0x0104011301e8 (6 bytes) 17:39:58.067 SERIAL » [ACK] (0x06) 17:39:58.068 DRIVER « [RES] [SendData] was sent: true 17:39:58.081 SERIAL « 0x01070013ba00000253 (9 bytes) 17:39:58.082 SERIAL » [ACK] (0x06) 17:39:58.082 DRIVER « [REQ] [SendData] callback id: 186 transmit status: OK 17:39:58.092 SERIAL « 0x010c000400110670060602001e8c (14 bytes) 17:39:58.100 CNTRLR [Node 017] [~] [Configuration] 6: 30 => 30 17:39:58.101 SERIAL » [ACK] (0x06) 17:39:58.102 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 6 value size: 2 value: 30 17:39:58.103 CNTRLR « [Node 017] parameter #6 has value: 30 17:39:58.104 CNTRLR » [Node 017] querying parameter #8 value... 17:39:58.108 SERIAL » 0x010a0013110370050825bb17 (12 bytes) 17:39:58.109 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 187 └─[ConfigurationCCGet] parameter #: 8 17:39:58.111 SERIAL « [ACK] (0x06) 17:39:58.117 SERIAL « 0x0104011301e8 (6 bytes) 17:39:58.117 SERIAL » [ACK] (0x06) 17:39:58.117 DRIVER « [RES] [SendData] was sent: true 17:39:58.134 SERIAL « 0x01070013bb00000252 (9 bytes) 17:39:58.134 SERIAL » [ACK] (0x06) 17:39:58.134 DRIVER « [REQ] [SendData] callback id: 187 transmit status: OK 17:39:58.144 SERIAL « 0x010b000400110570060801009b (13 bytes) 17:39:58.149 CNTRLR [Node 017] [~] [Configuration] 8: 0 => 0 17:39:58.150 SERIAL » [ACK] (0x06) 17:39:58.151 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 8 value size: 1 value: 0 17:39:58.152 CNTRLR « [Node 017] parameter #8 has value: 0 17:39:58.152 CNTRLR » [Node 017] querying parameter #9 value... 17:39:58.156 SERIAL » 0x010a0013110370050925bc11 (12 bytes) 17:39:58.156 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 188 └─[ConfigurationCCGet] parameter #: 9 17:39:58.175 SERIAL « [ACK] (0x06) 17:39:58.177 SERIAL « 0x0104011301e8 (6 bytes) 17:39:58.177 SERIAL » [ACK] (0x06) 17:39:58.178 DRIVER « [RES] [SendData] was sent: true 17:39:58.182 SERIAL « 0x01070013bc00000255 (9 bytes) 17:39:58.182 SERIAL » [ACK] (0x06) 17:39:58.183 DRIVER « [REQ] [SendData] callback id: 188 transmit status: OK 17:39:58.192 SERIAL « 0x010c0004001106700609020028b5 (14 bytes) 17:39:58.197 CNTRLR [Node 017] [~] [Configuration] 9: 40 => 40 17:39:58.198 SERIAL » [ACK] (0x06) 17:39:58.199 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 2 value: 40 17:39:58.201 CNTRLR « [Node 017] parameter #9 has value: 40 17:39:58.201 CNTRLR » [Node 017] querying parameter #12 value... 17:39:58.206 SERIAL » 0x010a0013110370050c25bd15 (12 bytes) 17:39:58.206 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 189 └─[ConfigurationCCGet] parameter #: 12 17:39:58.209 SERIAL « [ACK] (0x06) 17:39:58.215 SERIAL « 0x0104011301e8 (6 bytes) 17:39:58.215 SERIAL » [ACK] (0x06) 17:39:58.216 DRIVER « [RES] [SendData] was sent: true 17:39:58.231 SERIAL « 0x01070013bd00000254 (9 bytes) 17:39:58.232 SERIAL » [ACK] (0x06) 17:39:58.232 DRIVER « [REQ] [SendData] callback id: 189 transmit status: OK 17:39:58.242 SERIAL « 0x010b000400110570060c01009f (13 bytes) 17:39:58.247 CNTRLR [Node 017] [~] [Configuration] 12: 0 => 0 17:39:58.248 SERIAL » [ACK] (0x06) 17:39:58.249 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 1 value: 0 17:39:58.250 CNTRLR « [Node 017] parameter #12 has value: 0 17:39:58.250 CNTRLR » [Node 017] querying parameter #14 value... 17:39:58.256 SERIAL » 0x010a0013110370050e25be14 (12 bytes) 17:39:58.257 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 190 └─[ConfigurationCCGet] parameter #: 14 17:39:58.261 SERIAL « [ACK] (0x06) 17:39:58.266 SERIAL « 0x0104011301e8 (6 bytes) 17:39:58.267 SERIAL » [ACK] (0x06) 17:39:58.268 DRIVER « [RES] [SendData] was sent: true 17:39:58.282 SERIAL « 0x01070013be00000257 (9 bytes) 17:39:58.282 SERIAL » [ACK] (0x06) 17:39:58.283 DRIVER « [REQ] [SendData] callback id: 190 transmit status: OK 17:39:58.293 SERIAL « 0x010b000400110570060e01ff62 (13 bytes) 17:39:58.298 CNTRLR [Node 017] [~] [Configuration] 14: 255 => 255 17:39:58.298 SERIAL » [ACK] (0x06) 17:39:58.299 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 1 value: 255 17:39:58.301 CNTRLR « [Node 017] parameter #14 has value: 255 17:39:58.301 CNTRLR » [Node 017] querying parameter #16 value... 17:39:58.304 SERIAL » 0x010a0013110370051025bf0b (12 bytes) 17:39:58.305 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 191 └─[ConfigurationCCGet] parameter #: 16 17:39:58.307 SERIAL « [ACK] (0x06) 17:39:58.312 SERIAL « 0x0104011301e8 (6 bytes) 17:39:58.313 SERIAL » [ACK] (0x06) 17:39:58.313 DRIVER « [RES] [SendData] was sent: true 17:39:58.330 SERIAL « 0x01070013bf00000256 (9 bytes) 17:39:58.330 SERIAL » [ACK] (0x06) 17:39:58.330 DRIVER « [REQ] [SendData] callback id: 191 transmit status: OK 17:39:58.340 SERIAL « 0x010b0004001105700610010083 (13 bytes) 17:39:58.345 CNTRLR [Node 017] [~] [Configuration] 16: 0 => 0 17:39:58.346 SERIAL » [ACK] (0x06) 17:39:58.347 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 0 17:39:58.348 CNTRLR « [Node 017] parameter #16 has value: 0 17:39:58.348 CNTRLR » [Node 017] querying parameter #20 value... 17:39:58.351 SERIAL » 0x010a0013110370051425c070 (12 bytes) 17:39:58.352 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 192 └─[ConfigurationCCGet] parameter #: 20 17:39:58.354 SERIAL « [ACK] (0x06) 17:39:58.360 SERIAL « 0x0104011301e8 (6 bytes) 17:39:58.361 SERIAL » [ACK] (0x06) 17:39:58.362 DRIVER « [RES] [SendData] was sent: true 17:39:58.378 SERIAL « 0x01070013c000000328 (9 bytes) 17:39:58.378 SERIAL » [ACK] (0x06) 17:39:58.381 DRIVER « [REQ] [SendData] callback id: 192 transmit status: OK 17:39:58.389 SERIAL « 0x010b0004001105700614010f88 (13 bytes) 17:39:58.394 CNTRLR [Node 017] [~] [Configuration] 20: 15 => 15 17:39:58.395 SERIAL » [ACK] (0x06) 17:39:58.395 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 15 17:39:58.397 CNTRLR « [Node 017] parameter #20 has value: 15 17:39:58.397 CNTRLR » [Node 017] querying parameter #22 value... 17:39:58.400 SERIAL » 0x010a0013110370051625c173 (12 bytes) 17:39:58.401 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 193 └─[ConfigurationCCGet] parameter #: 22 17:39:58.403 SERIAL « [ACK] (0x06) 17:39:58.408 SERIAL « 0x0104011301e8 (6 bytes) 17:39:58.409 SERIAL » [ACK] (0x06) 17:39:58.409 DRIVER « [RES] [SendData] was sent: true 17:39:58.426 SERIAL « 0x01070013c100000228 (9 bytes) 17:39:58.426 SERIAL » [ACK] (0x06) 17:39:58.427 DRIVER « [REQ] [SendData] callback id: 193 transmit status: OK 17:39:58.437 SERIAL « 0x010c000400110670061602001e9c (14 bytes) 17:39:58.442 CNTRLR [Node 017] [~] [Configuration] 22: 30 => 30 17:39:58.442 SERIAL » [ACK] (0x06) 17:39:58.443 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 30 17:39:58.444 CNTRLR « [Node 017] parameter #22 has value: 30 17:39:58.445 CNTRLR » [Node 017] querying parameter #24 value... 17:39:58.448 SERIAL » 0x010a0013110370051825c27e (12 bytes) 17:39:58.448 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 194 └─[ConfigurationCCGet] parameter #: 24 17:39:58.451 SERIAL « [ACK] (0x06) 17:39:58.457 SERIAL « 0x0104011301e8 (6 bytes) 17:39:58.457 SERIAL » [ACK] (0x06) 17:39:58.459 DRIVER « [RES] [SendData] was sent: true 17:39:58.473 SERIAL « 0x01070013c20000022b (9 bytes) 17:39:58.474 SERIAL » [ACK] (0x06) 17:39:58.474 DRIVER « [REQ] [SendData] callback id: 194 transmit status: OK 17:39:58.484 SERIAL « 0x010b000400110570061801008b (13 bytes) 17:39:58.489 CNTRLR [Node 017] [~] [Configuration] 24: 0 => 0 17:39:58.490 SERIAL » [ACK] (0x06) 17:39:58.491 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 24 value size: 1 value: 0 17:39:58.492 CNTRLR « [Node 017] parameter #24 has value: 0 17:39:58.492 CNTRLR » [Node 017] querying parameter #26 value... 17:39:58.498 SERIAL » 0x010a0013110370051a25c37d (12 bytes) 17:39:58.498 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 195 └─[ConfigurationCCGet] parameter #: 26 17:39:58.501 SERIAL « [ACK] (0x06) 17:39:58.506 SERIAL « 0x0104011301e8 (6 bytes) 17:39:58.506 SERIAL » [ACK] (0x06) 17:39:58.507 DRIVER « [RES] [SendData] was sent: true 17:39:58.523 SERIAL « 0x01070013c30000022a (9 bytes) 17:39:58.524 SERIAL » [ACK] (0x06) 17:39:58.524 DRIVER « [REQ] [SendData] callback id: 195 transmit status: OK 17:39:58.534 SERIAL « 0x010b000400110570061a010089 (13 bytes) 17:39:58.539 CNTRLR [Node 017] [~] [Configuration] 26: 0 => 0 17:39:58.540 SERIAL » [ACK] (0x06) 17:39:58.541 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 26 value size: 1 value: 0 17:39:58.542 CNTRLR « [Node 017] parameter #26 has value: 0 17:39:58.542 CNTRLR » [Node 017] querying parameter #40 value... 17:39:58.546 SERIAL » 0x010a0013110370052825c448 (12 bytes) 17:39:58.546 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 196 └─[ConfigurationCCGet] parameter #: 40 17:39:58.548 SERIAL « [ACK] (0x06) 17:39:58.554 SERIAL « 0x0104011301e8 (6 bytes) 17:39:58.554 SERIAL » [ACK] (0x06) 17:39:58.555 DRIVER « [RES] [SendData] was sent: true 17:39:58.571 SERIAL « 0x01070013c40000022d (9 bytes) 17:39:58.571 SERIAL » [ACK] (0x06) 17:39:58.572 DRIVER « [REQ] [SendData] callback id: 196 transmit status: OK 17:39:58.582 SERIAL « 0x010c00040011067006280200c874 (14 bytes) 17:39:58.587 CNTRLR [Node 017] [~] [Configuration] 40: 200 => 200 17:39:58.588 SERIAL » [ACK] (0x06) 17:39:58.594 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 2 value: 200 17:39:58.596 CNTRLR « [Node 017] parameter #40 has value: 200 17:39:58.596 CNTRLR » [Node 017] querying parameter #42 value... 17:39:58.600 SERIAL » 0x010a0013110370052a25c54b (12 bytes) 17:39:58.600 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 197 └─[ConfigurationCCGet] parameter #: 42 17:39:58.603 SERIAL « [ACK] (0x06) 17:39:58.608 SERIAL « 0x0104011301e8 (6 bytes) 17:39:58.608 SERIAL » [ACK] (0x06) 17:39:58.609 DRIVER « [RES] [SendData] was sent: true 17:39:58.626 SERIAL « 0x01070013c50000022c (9 bytes) 17:39:58.626 SERIAL » [ACK] (0x06) 17:39:58.626 DRIVER « [REQ] [SendData] callback id: 197 transmit status: OK 17:39:58.636 SERIAL « 0x010c000400110670062a020000be (14 bytes) 17:39:58.641 CNTRLR [Node 017] [~] [Configuration] 42: 0 => 0 17:39:58.642 SERIAL » [ACK] (0x06) 17:39:58.664 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 2 value: 0 17:39:58.665 CNTRLR « [Node 017] parameter #42 has value: 0 17:39:58.665 CNTRLR » [Node 017] querying parameter #60 value... 17:39:58.669 SERIAL » 0x010a0013110370053c25c65e (12 bytes) 17:39:58.669 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 198 └─[ConfigurationCCGet] parameter #: 60 17:39:58.671 SERIAL « [ACK] (0x06) 17:39:58.681 SERIAL « 0x0104011301e8 (6 bytes) 17:39:58.681 SERIAL » [ACK] (0x06) 17:39:58.683 DRIVER « [RES] [SendData] was sent: true 17:39:58.694 SERIAL « 0x01070013c60000022f (9 bytes) 17:39:58.695 SERIAL » [ACK] (0x06) 17:39:58.695 DRIVER « [REQ] [SendData] callback id: 198 transmit status: OK 17:39:58.705 SERIAL « 0x010b000400110570063c010aa5 (13 bytes) 17:39:58.711 CNTRLR [Node 017] [~] [Configuration] 60: 10 => 10 17:39:58.711 SERIAL » [ACK] (0x06) 17:39:58.712 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 1 value: 10 17:39:58.714 CNTRLR « [Node 017] parameter #60 has value: 10 17:39:58.714 CNTRLR » [Node 017] querying parameter #62 value... 17:39:58.717 SERIAL » 0x010a0013110370053e25c75d (12 bytes) 17:39:58.718 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 199 └─[ConfigurationCCGet] parameter #: 62 17:39:58.720 SERIAL « [ACK] (0x06) 17:39:58.725 SERIAL « 0x0104011301e8 (6 bytes) 17:39:58.726 SERIAL » [ACK] (0x06) 17:39:58.726 DRIVER « [RES] [SendData] was sent: true 17:39:58.742 SERIAL « 0x01070013c70000022e (9 bytes) 17:39:58.743 SERIAL » [ACK] (0x06) 17:39:58.743 DRIVER « [REQ] [SendData] callback id: 199 transmit status: OK 17:39:58.754 SERIAL « 0x010c000400110670063e0203842d (14 bytes) 17:39:58.759 CNTRLR [Node 017] [~] [Configuration] 62: 900 => 900 17:39:58.760 SERIAL » [ACK] (0x06) 17:39:58.760 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 62 value size: 2 value: 900 17:39:58.761 CNTRLR « [Node 017] parameter #62 has value: 900 17:39:58.762 CNTRLR » [Node 017] querying parameter #64 value... 17:39:58.770 SERIAL » 0x010a0013110370054025c82c (12 bytes) 17:39:58.770 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 200 └─[ConfigurationCCGet] parameter #: 64 17:39:58.774 SERIAL « [ACK] (0x06) 17:39:58.778 SERIAL « 0x0104011301e8 (6 bytes) 17:39:58.783 SERIAL » [ACK] (0x06) 17:39:58.784 DRIVER « [RES] [SendData] was sent: true 17:39:58.795 SERIAL « 0x01070013c800000221 (9 bytes) 17:39:58.796 SERIAL » [ACK] (0x06) 17:39:58.796 DRIVER « [REQ] [SendData] callback id: 200 transmit status: OK 17:39:58.806 SERIAL « 0x010c0004001106700640020000d4 (14 bytes) 17:39:58.815 CNTRLR [Node 017] [~] [Configuration] 64: 0 => 0 17:39:58.817 SERIAL » [ACK] (0x06) 17:39:58.818 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 64 value size: 2 value: 0 17:39:58.820 CNTRLR « [Node 017] parameter #64 has value: 0 17:39:58.820 CNTRLR » [Node 017] querying parameter #66 value... 17:39:58.825 SERIAL » 0x010a0013110370054225c92f (12 bytes) 17:39:58.826 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 201 └─[ConfigurationCCGet] parameter #: 66 17:39:58.833 SERIAL « [ACK] (0x06) 17:39:58.835 SERIAL « 0x0104011301e8 (6 bytes) 17:39:58.835 SERIAL » [ACK] (0x06) 17:39:58.837 DRIVER « [RES] [SendData] was sent: true 17:39:58.851 SERIAL « 0x01070013c900000220 (9 bytes) 17:39:58.851 SERIAL » [ACK] (0x06) 17:39:58.852 DRIVER « [REQ] [SendData] callback id: 201 transmit status: OK 17:39:58.862 SERIAL « 0x010c0004001106700642020000d6 (14 bytes) 17:39:58.869 CNTRLR [Node 017] [~] [Configuration] 66: 0 => 0 17:39:58.870 SERIAL » [ACK] (0x06) 17:39:58.871 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 66 value size: 2 value: 0 17:39:58.873 CNTRLR « [Node 017] parameter #66 has value: 0 17:39:58.873 CNTRLR » [Node 017] querying parameter #80 value... 17:39:58.878 SERIAL » 0x010a0013110370055025ca3e (12 bytes) 17:39:58.878 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 202 └─[ConfigurationCCGet] parameter #: 80 17:39:58.884 SERIAL « [ACK] (0x06) 17:39:58.888 SERIAL « 0x0104011301e8 (6 bytes) 17:39:58.888 SERIAL » [ACK] (0x06) 17:39:58.892 DRIVER « [RES] [SendData] was sent: true 17:39:58.903 SERIAL « 0x01070013ca00000223 (9 bytes) 17:39:58.904 SERIAL » [ACK] (0x06) 17:39:58.904 DRIVER « [REQ] [SendData] callback id: 202 transmit status: OK 17:39:58.914 SERIAL « 0x010b00040011057006500100c3 (13 bytes) 17:39:58.927 CNTRLR [Node 017] [~] [Configuration] 80: 0 => 0 17:39:58.928 SERIAL » [ACK] (0x06) 17:39:58.929 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 80 value size: 1 value: 0 17:39:58.931 CNTRLR « [Node 017] parameter #80 has value: 0 17:39:58.931 CNTRLR » [Node 017] querying parameter #81 value... 17:39:58.936 SERIAL » 0x010a0013110370055125cb3e (12 bytes) 17:39:58.936 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 203 └─[ConfigurationCCGet] parameter #: 81 17:39:58.939 SERIAL « [ACK] (0x06) 17:39:58.945 SERIAL « 0x0104011301e8 (6 bytes) 17:39:58.945 SERIAL » [ACK] (0x06) 17:39:58.946 DRIVER « [RES] [SendData] was sent: true 17:39:58.961 SERIAL « 0x01070013cb00000222 (9 bytes) 17:39:58.962 SERIAL » [ACK] (0x06) 17:39:58.962 DRIVER « [REQ] [SendData] callback id: 203 transmit status: OK 17:39:58.972 SERIAL « 0x010b00040011057006510132f0 (13 bytes) 17:39:58.979 CNTRLR [Node 017] [~] [Configuration] 81: 50 => 50 17:39:58.980 SERIAL » [ACK] (0x06) 17:39:58.981 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 81 value size: 1 value: 50 17:39:58.983 CNTRLR « [Node 017] parameter #81 has value: 50 17:39:58.983 CNTRLR » [Node 017] querying parameter #82 value... 17:39:58.988 SERIAL » 0x010a0013110370055225cc3a (12 bytes) 17:39:58.988 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 204 └─[ConfigurationCCGet] parameter #: 82 17:39:58.995 SERIAL « [ACK] (0x06) 17:39:58.999 SERIAL « 0x0104011301e8 (6 bytes) 17:39:59.000 SERIAL » [ACK] (0x06) 17:39:59.002 DRIVER « [RES] [SendData] was sent: true 17:39:59.013 SERIAL « 0x01070013cc00000225 (9 bytes) 17:39:59.014 SERIAL » [ACK] (0x06) 17:39:59.015 DRIVER « [REQ] [SendData] callback id: 204 transmit status: OK 17:39:59.024 SERIAL « 0x010c0004001106700652020064a2 (14 bytes) 17:39:59.029 CNTRLR [Node 017] [~] [Configuration] 82: 100 => 100 17:39:59.030 SERIAL » [ACK] (0x06) 17:39:59.031 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 82 value size: 2 value: 100 17:39:59.032 CNTRLR « [Node 017] parameter #82 has value: 100 17:39:59.032 CNTRLR » [Node 017] querying parameter #83 value... 17:39:59.036 SERIAL » 0x010a0013110370055325cd3a (12 bytes) 17:39:59.037 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 205 └─[ConfigurationCCGet] parameter #: 83 17:39:59.040 SERIAL « [ACK] (0x06) 17:39:59.045 SERIAL « 0x0104011301e8 (6 bytes) 17:39:59.046 SERIAL » [ACK] (0x06) 17:39:59.047 DRIVER « [RES] [SendData] was sent: true 17:39:59.062 SERIAL « 0x01070013cd00000224 (9 bytes) 17:39:59.062 SERIAL » [ACK] (0x06) 17:39:59.063 DRIVER « [REQ] [SendData] callback id: 205 transmit status: OK 17:39:59.073 SERIAL « 0x010c00040011067006530203e82c (14 bytes) 17:39:59.078 CNTRLR [Node 017] [~] [Configuration] 83: 1000 => 1000 17:39:59.079 SERIAL » [ACK] (0x06) 17:39:59.079 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 83 value size: 2 value: 1000 17:39:59.080 CNTRLR « [Node 017] parameter #83 has value: 1000 17:39:59.081 CNTRLR » [Node 017] querying parameter #86 value... 17:39:59.084 SERIAL » 0x010a0013110370055625ce3c (12 bytes) 17:39:59.084 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 206 └─[ConfigurationCCGet] parameter #: 86 17:39:59.087 SERIAL « [ACK] (0x06) 17:39:59.093 SERIAL « 0x0104011301e8 (6 bytes) 17:39:59.093 SERIAL » [ACK] (0x06) 17:39:59.094 DRIVER « [RES] [SendData] was sent: true 17:39:59.111 SERIAL « 0x01070013ce00000227 (9 bytes) 17:39:59.111 SERIAL » [ACK] (0x06) 17:39:59.112 DRIVER « [REQ] [SendData] callback id: 206 transmit status: OK 17:39:59.120 SERIAL « 0x010b00040011057006560112d7 (13 bytes) 17:39:59.125 CNTRLR [Node 017] [~] [Configuration] 86: 18 => 18 17:39:59.126 SERIAL » [ACK] (0x06) 17:39:59.127 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 86 value size: 1 value: 18 17:39:59.128 CNTRLR « [Node 017] parameter #86 has value: 18 17:39:59.128 CNTRLR » [Node 017] querying parameter #87 value... 17:39:59.131 SERIAL » 0x010a0013110370055725cf3c (12 bytes) 17:39:59.132 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 207 └─[ConfigurationCCGet] parameter #: 87 17:39:59.134 SERIAL « [ACK] (0x06) 17:39:59.140 SERIAL « 0x0104011301e8 (6 bytes) 17:39:59.141 SERIAL » [ACK] (0x06) 17:39:59.142 DRIVER « [RES] [SendData] was sent: true 17:39:59.157 SERIAL « 0x01070013cf00000327 (9 bytes) 17:39:59.157 SERIAL » [ACK] (0x06) 17:39:59.158 DRIVER « [REQ] [SendData] callback id: 207 transmit status: OK 17:39:59.168 SERIAL « 0x010b0004001105700657011cd8 (13 bytes) 17:39:59.173 CNTRLR [Node 017] [~] [Configuration] 87: 28 => 28 17:39:59.174 SERIAL » [ACK] (0x06) 17:39:59.174 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 87 value size: 1 value: 28 17:39:59.176 CNTRLR « [Node 017] parameter #87 has value: 28 17:39:59.176 CNTRLR » [Node 017] querying parameter #89 value... 17:39:59.179 SERIAL » 0x010a0013110370055925d02d (12 bytes) 17:39:59.180 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 208 └─[ConfigurationCCGet] parameter #: 89 17:39:59.183 SERIAL « [ACK] (0x06) 17:39:59.188 SERIAL « 0x0104011301e8 (6 bytes) 17:39:59.188 SERIAL » [ACK] (0x06) 17:39:59.189 DRIVER « [RES] [SendData] was sent: true 17:39:59.205 SERIAL « 0x01070013d000000239 (9 bytes) 17:39:59.205 SERIAL » [ACK] (0x06) 17:39:59.206 DRIVER « [REQ] [SendData] callback id: 208 transmit status: OK 17:39:59.216 SERIAL « 0x010b00040011057006590101cb (13 bytes) 17:39:59.221 CNTRLR [Node 017] [~] [Configuration] 89: 1 => 1 17:39:59.222 SERIAL » [ACK] (0x06) 17:39:59.222 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 89 value size: 1 value: 1 17:39:59.224 CNTRLR « [Node 017] parameter #89 has value: 1 17:39:59.224 CNTRLR [Node 017] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 17:39:59.263 CNTRLR [Node 017] AlarmSensorCC: doing a partial interview... 17:39:59.263 CNTRLR » [Node 017] querying current value for General Purpose... 17:39:59.268 SERIAL » 0x010a001311039c010025d19d (12 bytes) 17:39:59.268 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 209 └─[AlarmSensorCCGet] sensor type: General Purpose 17:39:59.270 SERIAL « [ACK] (0x06) 17:39:59.276 SERIAL « 0x0104011301e8 (6 bytes) 17:39:59.277 SERIAL » [ACK] (0x06) 17:39:59.277 DRIVER « [RES] [SendData] was sent: true 17:39:59.293 SERIAL « 0x01070013d100000238 (9 bytes) 17:39:59.294 SERIAL » [ACK] (0x06) 17:39:59.294 DRIVER « [REQ] [SendData] callback id: 209 transmit status: OK 17:39:59.304 SERIAL « 0x010d00040011079c0211000000006f (15 bytes) 17:39:59.305 CNTRLR [Node 017] [~] [Alarm Sensor] state[0]: false => false [Endpoint 0] 17:39:59.306 CNTRLR [Node 017] [+] [Alarm Sensor] severity[0]: undefined [Endpoint 0] 17:39:59.306 CNTRLR [Node 017] [+] [Alarm Sensor] duration[0]: undefined [Endpoint 0] 17:39:59.307 SERIAL » [ACK] (0x06) 17:39:59.308 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: false 17:39:59.309 CNTRLR « [Node 017] received current value for General Purpose: state: false 17:39:59.310 CNTRLR [Node 017] [~] [Alarm Sensor] interviewComplete: true [Endpoint 0] [internal] => true 17:39:59.310 CNTRLR [Node 017] MultiChannelAssociationCC: doing a partial interview... 17:39:59.310 CNTRLR » [Node 017] querying multi channel association group #1... 17:39:59.313 SERIAL » 0x010a001311038e020125d28e (12 bytes) 17:39:59.314 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 210 └─[MultiChannelAssociationCCGet] group id: 1 17:39:59.317 SERIAL « [ACK] (0x06) 17:39:59.322 SERIAL « 0x0104011301e8 (6 bytes) 17:39:59.322 SERIAL » [ACK] (0x06) 17:39:59.324 DRIVER « [RES] [SendData] was sent: true 17:39:59.339 SERIAL « 0x01070013d20000023b (9 bytes) 17:39:59.339 SERIAL » [ACK] (0x06) 17:39:59.340 DRIVER « [REQ] [SendData] callback id: 210 transmit status: OK 17:39:59.350 SERIAL « 0x010c00040011068e030105000168 (14 bytes) 17:39:59.350 SERIAL » [ACK] (0x06) 17:39:59.351 CNTRLR [Node 017] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 17:39:59.352 CNTRLR [Node 017] [~] [Multi Channel Association] nodeIds[1]: 1 => 1 17:39:59.353 CNTRLR [Node 017] [~] [Multi Channel Association] endpoints[1]: => 17:39:59.354 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: 1 endpoints: 17:39:59.355 CNTRLR « [Node 017] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 17:39:59.355 CNTRLR » [Node 017] querying multi channel association group #2... 17:39:59.359 SERIAL » 0x010a001311038e020225d38c (12 bytes) 17:39:59.359 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 211 └─[MultiChannelAssociationCCGet] group id: 2 17:39:59.361 SERIAL « [ACK] (0x06) 17:39:59.370 SERIAL « 0x0104011301e8 (6 bytes) 17:39:59.371 SERIAL » [ACK] (0x06) 17:39:59.372 DRIVER « [RES] [SendData] was sent: true 17:39:59.385 SERIAL « 0x01070013d30000023a (9 bytes) 17:39:59.386 SERIAL » [ACK] (0x06) 17:39:59.387 DRIVER « [REQ] [SendData] callback id: 211 transmit status: OK 17:39:59.396 SERIAL « 0x010c00040011068e03020500016b (14 bytes) 17:39:59.396 SERIAL » [ACK] (0x06) 17:39:59.397 CNTRLR [Node 017] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 17:39:59.398 CNTRLR [Node 017] [~] [Multi Channel Association] nodeIds[2]: 1 => 1 17:39:59.400 CNTRLR [Node 017] [~] [Multi Channel Association] endpoints[2]: => 17:39:59.400 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: 1 endpoints: 17:39:59.402 CNTRLR « [Node 017] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: 1 currently assigned endpoints: 17:39:59.402 CNTRLR » [Node 017] querying additional non-multi-channel association groups... 17:39:59.402 CNTRLR » [Node 017] querying association group #3... 17:39:59.406 SERIAL » 0x010a0013110385020325d481 (12 bytes) 17:39:59.406 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 212 └─[AssociationCCGet] group id: 3 17:39:59.409 SERIAL « [ACK] (0x06) 17:39:59.420 SERIAL « 0x0104011301e8 (6 bytes) 17:39:59.421 SERIAL » [ACK] (0x06) 17:39:59.423 DRIVER « [RES] [SendData] was sent: true 17:39:59.431 SERIAL « 0x01070013d40000023d (9 bytes) 17:39:59.432 SERIAL » [ACK] (0x06) 17:39:59.432 DRIVER « [REQ] [SendData] callback id: 212 transmit status: OK 17:39:59.443 SERIAL « 0x010c000400110685030301000165 (14 bytes) 17:39:59.443 SERIAL » [ACK] (0x06) 17:39:59.444 CNTRLR [Node 017] [~] [Association] maxNodes[3]: 1 => 1 [internal] 17:39:59.444 CNTRLR [Node 017] [~] [Association] nodeIds[3]: 1 => 1 [internal] 17:39:59.445 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 17:39:59.446 CNTRLR « [Node 017] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 17:39:59.446 CNTRLR [Node 017] [~] [Association] hasLifeline: true => true [internal] 17:39:59.447 CNTRLR [Node 017] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 17:39:59.480 CNTRLR [Node 017] Interview stage completed: CommandClasses 17:39:59.480 CNTRLR [Node 017] Interview stage completed: OverwriteConfig 17:39:59.480 CNTRLR » [Node 017] requesting node neighbors... 17:39:59.483 SERIAL » 0x010700801100000069 (9 bytes) 17:39:59.484 DRIVER » [Node 017] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 17:39:59.485 SERIAL « [ACK] (0x06) 17:39:59.488 SERIAL « 0x0120018005c000000000000000000000000000000000000000000000000000000 (34 bytes) 09b 17:39:59.488 SERIAL » [ACK] (0x06) 17:39:59.489 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 15, 16 17:39:59.491 CNTRLR « [Node 017] node neighbors received: 1, 3, 15, 16 17:39:59.491 CNTRLR [Node 017] Interview stage completed: Neighbors 17:39:59.491 CNTRLR [Node 017] Interview completed 17:40:00.491 CNTRLR » [Node 017] Sending node back to sleep... 17:40:00.494 SERIAL » 0x010900131102840825d58a (11 bytes) 17:40:00.495 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 213 └─[WakeUpCCNoMoreInformation] 17:40:00.496 SERIAL « [ACK] (0x06) 17:40:00.503 SERIAL « 0x0104011301e8 (6 bytes) 17:40:00.503 SERIAL » [ACK] (0x06) 17:40:00.503 DRIVER « [RES] [SendData] was sent: true 17:40:00.519 SERIAL « 0x01070013d50000023c (9 bytes) 17:40:00.520 SERIAL » [ACK] (0x06) 17:40:00.520 DRIVER « [REQ] [SendData] callback id: 213 transmit status: OK 17:40:00.523 CNTRLR [Node 017] The node is now asleep. 17:40:12.971 SERIAL « 0x010c0004000306310504220801e9 (14 bytes) 17:40:12.973 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:40:12.973 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 256.6 => 204.9 [Endpoint 0] 17:40:12.974 SERIAL » [ACK] (0x06) 17:40:12.976 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 204.9 17:40:15.972 SERIAL « 0x010c00040003063105042205d134 (14 bytes) 17:40:15.973 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:40:15.974 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 204.9 => 148.9 [Endpoint 0] 17:40:15.975 SERIAL » [ACK] (0x06) 17:40:15.977 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 148.9 17:40:16.972 SERIAL « 0x010c000400030631050422030eed (14 bytes) 17:40:16.973 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:40:16.974 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 148.9 => 78.2 [Endpoint 0] 17:40:16.975 SERIAL » [ACK] (0x06) 17:40:16.977 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 78.2 17:40:17.972 SERIAL « 0x010c0004000306310504220a29c3 (14 bytes) 17:40:17.974 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:40:17.976 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 78.2 => 260.1 [Endpoint 0] 17:40:17.977 SERIAL » [ACK] (0x06) 17:40:17.979 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 260.1 17:40:18.972 SERIAL « 0x010c00040003063105042207688f (14 bytes) 17:40:18.975 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:40:18.976 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 260.1 => 189.6 [Endpoint 0] 17:40:18.977 SERIAL » [ACK] (0x06) 17:40:18.979 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 189.6 17:40:25.745 SERIAL « 0x010900040008033003ff35 (11 bytes) 17:40:25.746 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:40:25.747 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:40:25.748 SERIAL » [ACK] (0x06) 17:40:25.750 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:40:25.799 SERIAL « 0x010900040008032001ff27 (11 bytes) 17:40:25.800 SERIAL » [ACK] (0x06) 17:40:25.801 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:40:25.803 CNTRLR [Node 008] treating BasicCC Set as a report 17:40:25.803 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:40:42.947 SERIAL « 0x01080004001e0284076c (10 bytes) 17:40:42.947 SERIAL » [ACK] (0x06) 17:40:42.948 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:40:42.949 CNTRLR « [Node 030] received wakeup notification 17:40:42.949 CNTRLR [Node 030] The node is now awake. 17:40:43.950 CNTRLR » [Node 030] Sending node back to sleep... 17:40:43.959 SERIAL » 0x010900131e02840825d686 (11 bytes) 17:40:43.959 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 214 └─[WakeUpCCNoMoreInformation] 17:40:43.962 SERIAL « [ACK] (0x06) 17:40:43.968 SERIAL « 0x0104011301e8 (6 bytes) 17:40:43.968 SERIAL » [ACK] (0x06) 17:40:43.969 DRIVER « [RES] [SendData] was sent: true 17:40:43.976 SERIAL « 0x010c000400030631050422095eb7 (14 bytes) 17:40:43.977 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:40:43.978 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 189.6 => 239.8 [Endpoint 0] 17:40:43.979 SERIAL » [ACK] (0x06) 17:40:43.981 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 239.8 17:40:43.997 SERIAL « 0x01070013d600000439 (9 bytes) 17:40:43.998 SERIAL » [ACK] (0x06) 17:40:43.999 DRIVER « [REQ] [SendData] callback id: 214 transmit status: OK 17:40:44.007 CNTRLR [Node 030] The node is now asleep. 17:40:45.975 SERIAL « 0x010c0004000306310504220404e0 (14 bytes) 17:40:45.976 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:40:45.978 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 239.8 => 102.8 [Endpoint 0] 17:40:45.978 SERIAL » [ACK] (0x06) 17:40:45.980 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 102.8 17:40:49.975 SERIAL « 0x010c00040003063105042204a246 (14 bytes) 17:40:49.976 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:40:49.978 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 102.8 => 118.6 [Endpoint 0] 17:40:49.978 SERIAL » [ACK] (0x06) 17:40:49.980 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 118.6 17:40:52.599 SERIAL » 0x010a00130e0326010025d73e (12 bytes) 17:40:52.599 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 215 └─[MultilevelSwitchCCSet] target value: 0 17:40:52.607 SERIAL « [ACK] (0x06) 17:40:52.608 SERIAL « 0x0104011301e8 (6 bytes) 17:40:52.608 SERIAL » [ACK] (0x06) 17:40:52.609 DRIVER « [RES] [SendData] was sent: true 17:40:52.625 SERIAL « 0x01070013d70000023e (9 bytes) 17:40:52.625 SERIAL » [ACK] (0x06) 17:40:52.626 DRIVER « [REQ] [SendData] callback id: 215 transmit status: OK 17:40:52.629 SERIAL » 0x010a00130d0326010025d832 (12 bytes) 17:40:52.630 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 216 └─[MultilevelSwitchCCSet] target value: 0 17:40:52.633 SERIAL « [ACK] (0x06) 17:40:52.637 SERIAL « 0x0104011301e8 (6 bytes) 17:40:52.638 SERIAL » [ACK] (0x06) 17:40:52.638 DRIVER « [RES] [SendData] was sent: true 17:40:52.685 SERIAL « 0x01070013d800000536 (9 bytes) 17:40:52.685 SERIAL » [ACK] (0x06) 17:40:52.685 DRIVER « [REQ] [SendData] callback id: 216 transmit status: OK 17:40:52.692 SERIAL » 0x010900130e02260225d931 (11 bytes) 17:40:52.693 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 217 └─[MultilevelSwitchCCGet] 17:40:52.695 SERIAL « [ACK] (0x06) 17:40:52.700 SERIAL « 0x0104011301e8 (6 bytes) 17:40:52.701 SERIAL » [ACK] (0x06) 17:40:52.701 DRIVER « [RES] [SendData] was sent: true 17:40:52.717 SERIAL « 0x01070013d900000331 (9 bytes) 17:40:52.718 SERIAL » [ACK] (0x06) 17:40:52.718 DRIVER « [REQ] [SendData] callback id: 217 transmit status: OK 17:40:52.729 SERIAL « 0x01090004000e03260363b9 (11 bytes) 17:40:52.730 CNTRLR [Node 014] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 0] 17:40:52.731 SERIAL » [ACK] (0x06) 17:40:52.732 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 99 17:40:52.735 SERIAL » 0x010900130d02260225da31 (11 bytes) 17:40:52.735 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 218 └─[MultilevelSwitchCCGet] 17:40:52.737 SERIAL « [ACK] (0x06) 17:40:52.743 SERIAL « 0x0104011301e8 (6 bytes) 17:40:52.743 SERIAL » [ACK] (0x06) 17:40:52.744 DRIVER « [RES] [SendData] was sent: true 17:40:52.789 SERIAL « 0x01070013da00000534 (9 bytes) 17:40:52.789 SERIAL » [ACK] (0x06) 17:40:52.790 DRIVER « [REQ] [SendData] callback id: 218 transmit status: OK 17:40:52.839 SERIAL « 0x01090004000d03260363ba (11 bytes) 17:40:52.840 CNTRLR [Node 013] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 0] 17:40:52.841 SERIAL » [ACK] (0x06) 17:40:52.841 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 99 17:40:53.767 SERIAL « 0x010c0004000e0631050422082ecb (14 bytes) 17:40:53.768 CNTRLR [Node 014] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:40:53.768 CNTRLR [Node 014] [~] [Multilevel Sensor] Power: 0 => 209.4 [Endpoint 0] 17:40:53.769 SERIAL » [ACK] (0x06) 17:40:53.770 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 209.4 17:40:53.819 SERIAL « 0x010c0004000d06310504220647af (14 bytes) 17:40:53.820 CNTRLR [Node 013] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:40:53.820 CNTRLR [Node 013] [~] [Multilevel Sensor] Power: 0 => 160.7 [Endpoint 0] 17:40:53.821 SERIAL » [ACK] (0x06) 17:40:53.822 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 160.7 17:40:54.788 SERIAL « 0x010c0004000e063105042205b75f (14 bytes) 17:40:54.789 CNTRLR [Node 014] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:40:54.790 CNTRLR [Node 014] [~] [Multilevel Sensor] Power: 209.4 => 146.3 [Endpoint 0] 17:40:54.790 SERIAL » [ACK] (0x06) 17:40:54.791 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 146.3 17:40:55.195 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 17:40:55.195 SERIAL » [ACK] (0x06) 17:40:55.196 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 17:40:55.197 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 17:40:56.356 SERIAL « 0x010900040015033003ff28 (11 bytes) 17:40:56.357 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:40:56.358 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:40:56.359 SERIAL » [ACK] (0x06) 17:40:56.360 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:40:56.410 SERIAL « 0x010900040015032001ff3a (11 bytes) 17:40:56.411 SERIAL » [ACK] (0x06) 17:40:56.411 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:40:56.415 CNTRLR [Node 021] treating BasicCC Set as a report 17:40:56.415 CNTRLR [Node 021] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:41:01.104 SERIAL » 0x010a0013140326016325db4b (12 bytes) 17:41:01.105 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 219 └─[MultilevelSwitchCCSet] target value: 99 17:41:01.108 SERIAL « [ACK] (0x06) 17:41:01.114 SERIAL « 0x0104011301e8 (6 bytes) 17:41:01.115 SERIAL » [ACK] (0x06) 17:41:01.116 DRIVER « [RES] [SendData] was sent: true 17:41:01.212 SERIAL « 0x01070013db00000a3a (9 bytes) 17:41:01.213 SERIAL » [ACK] (0x06) 17:41:01.214 DRIVER « [REQ] [SendData] callback id: 219 transmit status: OK 17:41:01.221 SERIAL » 0x010a0013130326016325dc4b (12 bytes) 17:41:01.221 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 220 └─[MultilevelSwitchCCSet] target value: 99 17:41:01.227 SERIAL « [ACK] (0x06) 17:41:01.232 SERIAL « 0x0104011301e8 (6 bytes) 17:41:01.233 SERIAL » [ACK] (0x06) 17:41:01.234 DRIVER « [RES] [SendData] was sent: true 17:41:01.247 SERIAL « 0x01070013dc00000334 (9 bytes) 17:41:01.248 SERIAL » [ACK] (0x06) 17:41:01.249 DRIVER « [REQ] [SendData] callback id: 220 transmit status: OK 17:41:01.256 SERIAL » 0x010900131402260225dd2f (11 bytes) 17:41:01.256 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 221 └─[MultilevelSwitchCCGet] 17:41:01.261 SERIAL « [ACK] (0x06) 17:41:01.264 SERIAL « 0x0104011301e8 (6 bytes) 17:41:01.265 SERIAL » [ACK] (0x06) 17:41:01.266 DRIVER « [RES] [SendData] was sent: true 17:41:01.359 SERIAL « 0x01070013dd00000a3c (9 bytes) 17:41:01.360 SERIAL » [ACK] (0x06) 17:41:01.361 DRIVER « [REQ] [SendData] callback id: 221 transmit status: OK 17:41:01.508 SERIAL « 0x01090004001403260301c1 (11 bytes) 17:41:01.509 CNTRLR [Node 020] [~] [Multilevel Switch] currentValue: 1 => 1 [Endpoint 0] 17:41:01.510 SERIAL » [ACK] (0x06) 17:41:01.511 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 1 17:41:01.522 SERIAL » 0x010900131302260225de2b (11 bytes) 17:41:01.523 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 222 └─[MultilevelSwitchCCGet] 17:41:01.527 SERIAL « [ACK] (0x06) 17:41:01.532 SERIAL « 0x0104011301e8 (6 bytes) 17:41:01.533 SERIAL » [ACK] (0x06) 17:41:01.534 DRIVER « [RES] [SendData] was sent: true 17:41:01.603 SERIAL « 0x01070013de00000732 (9 bytes) 17:41:01.603 SERIAL » [ACK] (0x06) 17:41:01.604 DRIVER « [REQ] [SendData] callback id: 222 transmit status: OK 17:41:01.613 SERIAL « 0x01090004001303260363a4 (11 bytes) 17:41:01.614 CNTRLR [Node 019] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 0] 17:41:01.615 SERIAL » [ACK] (0x06) 17:41:01.616 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 99 17:41:02.344 SERIAL « 0x010c00040014063105042205e012 (14 bytes) 17:41:02.345 CNTRLR [Node 020] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:02.347 CNTRLR [Node 020] [~] [Multilevel Sensor] Power: 0 => 150.4 [Endpoint 0] 17:41:02.347 SERIAL » [ACK] (0x06) 17:41:02.349 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 150.4 17:41:03.290 SERIAL « 0x01090004001303260363a4 (11 bytes) 17:41:03.291 CNTRLR [Node 019] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 0] 17:41:03.292 SERIAL » [ACK] (0x06) 17:41:03.294 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 99 17:41:03.309 SERIAL « 0x010c0004001306310504220000f0 (14 bytes) 17:41:03.310 CNTRLR [Node 019] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:03.311 CNTRLR [Node 019] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 17:41:03.312 SERIAL » [ACK] (0x06) 17:41:03.315 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:41:09.069 SERIAL « 0x010c0004000d0631050422028569 (14 bytes) 17:41:09.070 CNTRLR [Node 013] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:09.070 CNTRLR [Node 013] [~] [Multilevel Sensor] Power: 160.7 => 64.5 [Endpoint 0] 17:41:09.071 SERIAL » [ACK] (0x06) 17:41:09.072 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 64.5 17:41:10.751 SERIAL « 0x01090004000d03260300d9 (11 bytes) 17:41:10.753 CNTRLR [Node 013] [~] [Multilevel Switch] currentValue: 99 => 0 [Endpoint 0] 17:41:10.754 SERIAL » [ACK] (0x06) 17:41:10.756 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 0 17:41:10.804 SERIAL « 0x010c0004000d06310504220000ee (14 bytes) 17:41:10.805 CNTRLR [Node 013] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:10.806 CNTRLR [Node 013] [~] [Multilevel Sensor] Power: 64.5 => 0 [Endpoint 0] 17:41:10.807 SERIAL » [ACK] (0x06) 17:41:10.809 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:41:11.978 SERIAL « 0x010c000400030631050422086880 (14 bytes) 17:41:11.978 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:11.979 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 118.6 => 215.2 [Endpoint 0] 17:41:11.979 SERIAL » [ACK] (0x06) 17:41:11.980 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 215.2 17:41:12.977 SERIAL « 0x010c000400030631050422047b9f (14 bytes) 17:41:12.978 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:12.979 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 215.2 => 114.7 [Endpoint 0] 17:41:12.979 SERIAL » [ACK] (0x06) 17:41:12.980 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 114.7 17:41:13.442 SERIAL » 0x010a0013100326010025df28 (12 bytes) 17:41:13.443 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 223 └─[MultilevelSwitchCCSet] target value: 0 17:41:13.446 SERIAL « [ACK] (0x06) 17:41:13.452 SERIAL « 0x0104011301e8 (6 bytes) 17:41:13.452 SERIAL » [ACK] (0x06) 17:41:13.453 DRIVER « [RES] [SendData] was sent: true 17:41:13.490 SERIAL « 0x01070013df00000531 (9 bytes) 17:41:13.490 SERIAL » [ACK] (0x06) 17:41:13.491 DRIVER « [REQ] [SendData] callback id: 223 transmit status: OK 17:41:13.496 SERIAL » 0x010900131002260225e016 (11 bytes) 17:41:13.496 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 224 └─[MultilevelSwitchCCGet] 17:41:13.498 SERIAL « [ACK] (0x06) 17:41:13.504 SERIAL « 0x0104011301e8 (6 bytes) 17:41:13.504 SERIAL » [ACK] (0x06) 17:41:13.505 DRIVER « [RES] [SendData] was sent: true 17:41:13.542 SERIAL « 0x01070013e00000040f (9 bytes) 17:41:13.543 SERIAL » [ACK] (0x06) 17:41:13.543 DRIVER « [REQ] [SendData] callback id: 224 transmit status: OK 17:41:13.589 SERIAL « 0x01090004001003260363a7 (11 bytes) 17:41:13.590 CNTRLR [Node 016] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 0] 17:41:13.590 SERIAL » [ACK] (0x06) 17:41:13.591 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 99 17:41:14.639 SERIAL « 0x010c00040010063105042204ab5c (14 bytes) 17:41:14.640 CNTRLR [Node 016] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:14.641 CNTRLR [Node 016] [~] [Multilevel Sensor] Power: 0 => 119.5 [Endpoint 0] 17:41:14.642 SERIAL » [ACK] (0x06) 17:41:14.644 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 119.5 17:41:17.265 SERIAL « 0x010c0004000e063105042200c32e (14 bytes) 17:41:17.266 CNTRLR [Node 014] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:17.268 CNTRLR [Node 014] [~] [Multilevel Sensor] Power: 146.3 => 19.5 [Endpoint 0] 17:41:17.270 SERIAL » [ACK] (0x06) 17:41:17.273 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 19.5 17:41:17.606 SERIAL « 0x010c0004001406310504220000f7 (14 bytes) 17:41:17.606 CNTRLR [Node 020] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:17.607 CNTRLR [Node 020] [~] [Multilevel Sensor] Power: 150.4 => 0 [Endpoint 0] 17:41:17.607 SERIAL » [ACK] (0x06) 17:41:17.608 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:41:18.867 SERIAL « 0x01090004001403260363a3 (11 bytes) 17:41:18.868 CNTRLR [Node 020] [~] [Multilevel Switch] currentValue: 1 => 99 [Endpoint 0] 17:41:18.869 SERIAL » [ACK] (0x06) 17:41:18.870 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 99 17:41:18.877 SERIAL « 0x01090004000e03260300da (11 bytes) 17:41:18.877 CNTRLR [Node 014] [~] [Multilevel Switch] currentValue: 99 => 0 [Endpoint 0] 17:41:18.878 SERIAL » [ACK] (0x06) 17:41:18.879 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 0 17:41:18.992 SERIAL « 0x010c0004001406310504220000f7 (14 bytes) 17:41:18.994 CNTRLR [Node 020] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:18.995 CNTRLR [Node 020] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 17:41:18.995 SERIAL » [ACK] (0x06) 17:41:18.997 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:41:19.115 SERIAL « 0x010c0004000e06310504220000ed (14 bytes) 17:41:19.117 CNTRLR [Node 014] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:19.118 CNTRLR [Node 014] [~] [Multilevel Sensor] Power: 19.5 => 0 [Endpoint 0] 17:41:19.118 SERIAL » [ACK] (0x06) 17:41:19.121 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:41:21.745 SERIAL » 0x010a0013140326010025e112 (12 bytes) 17:41:21.746 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 225 └─[MultilevelSwitchCCSet] target value: 0 17:41:21.748 SERIAL « [ACK] (0x06) 17:41:21.754 SERIAL « 0x0104011301e8 (6 bytes) 17:41:21.755 SERIAL » [ACK] (0x06) 17:41:21.755 DRIVER « [RES] [SendData] was sent: true 17:41:21.880 SERIAL « 0x01070013e100000d07 (9 bytes) 17:41:21.880 SERIAL » [ACK] (0x06) 17:41:21.881 DRIVER « [REQ] [SendData] callback id: 225 transmit status: OK 17:41:21.884 SERIAL » 0x010a0013130326010025e216 (12 bytes) 17:41:21.885 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 226 └─[MultilevelSwitchCCSet] target value: 0 17:41:21.888 SERIAL « [ACK] (0x06) 17:41:21.893 SERIAL « 0x0104011301e8 (6 bytes) 17:41:21.893 SERIAL » [ACK] (0x06) 17:41:21.894 DRIVER « [RES] [SendData] was sent: true 17:41:21.910 SERIAL « 0x01070013e20000020b (9 bytes) 17:41:21.910 SERIAL » [ACK] (0x06) 17:41:21.911 DRIVER « [REQ] [SendData] callback id: 226 transmit status: OK 17:41:21.914 SERIAL » 0x010900131402260225e311 (11 bytes) 17:41:21.915 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 227 └─[MultilevelSwitchCCGet] 17:41:21.920 SERIAL « [ACK] (0x06) 17:41:21.922 SERIAL « 0x0104011301e8 (6 bytes) 17:41:21.923 SERIAL » [ACK] (0x06) 17:41:21.923 DRIVER « [RES] [SendData] was sent: true 17:41:22.017 SERIAL « 0x01070013e300000a02 (9 bytes) 17:41:22.018 SERIAL » [ACK] (0x06) 17:41:22.019 DRIVER « [REQ] [SendData] callback id: 227 transmit status: OK 17:41:22.118 SERIAL « 0x01090004001403260363a3 (11 bytes) 17:41:22.118 CNTRLR [Node 020] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 0] 17:41:22.119 SERIAL » [ACK] (0x06) 17:41:22.120 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 99 17:41:22.124 SERIAL » 0x010900131302260225e411 (11 bytes) 17:41:22.124 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 228 └─[MultilevelSwitchCCGet] 17:41:22.129 SERIAL « [ACK] (0x06) 17:41:22.135 SERIAL « 0x0104011301e8 (6 bytes) 17:41:22.135 SERIAL » [ACK] (0x06) 17:41:22.136 DRIVER « [RES] [SendData] was sent: true 17:41:22.212 SERIAL « 0x01070013e400000807 (9 bytes) 17:41:22.213 SERIAL » [ACK] (0x06) 17:41:22.213 DRIVER « [REQ] [SendData] callback id: 228 transmit status: OK 17:41:22.223 SERIAL « 0x01090004001303260363a4 (11 bytes) 17:41:22.224 CNTRLR [Node 019] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 0] 17:41:22.224 SERIAL » [ACK] (0x06) 17:41:22.226 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 99 17:41:22.972 SERIAL « 0x010c00040014063105042205f103 (14 bytes) 17:41:22.972 CNTRLR [Node 020] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:22.973 CNTRLR [Node 020] [~] [Multilevel Sensor] Power: 0 => 152.1 [Endpoint 0] 17:41:22.973 SERIAL » [ACK] (0x06) 17:41:22.974 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 152.1 17:41:23.034 SERIAL « 0x010c0004001306310504220553a6 (14 bytes) 17:41:23.035 CNTRLR [Node 019] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:23.035 CNTRLR [Node 019] [~] [Multilevel Sensor] Power: 0 => 136.3 [Endpoint 0] 17:41:23.036 SERIAL » [ACK] (0x06) 17:41:23.037 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 136.3 17:41:30.628 SERIAL « 0x01090004001e033003ff23 (11 bytes) 17:41:30.629 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:41:30.629 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:41:30.630 SERIAL » [ACK] (0x06) 17:41:30.631 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:41:30.682 SERIAL « 0x01090004001e032001ff31 (11 bytes) 17:41:30.683 SERIAL » [ACK] (0x06) 17:41:30.684 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:41:30.686 CNTRLR [Node 030] treating BasicCC Set as a report 17:41:30.686 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:41:30.975 SERIAL « 0x010c0004001006310504220000f3 (14 bytes) 17:41:30.976 CNTRLR [Node 016] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:30.977 CNTRLR [Node 016] [~] [Multilevel Sensor] Power: 119.5 => 0 [Endpoint 0] 17:41:30.978 SERIAL » [ACK] (0x06) 17:41:30.980 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:41:31.688 SERIAL « 0x010900040007033003ff3a (11 bytes) 17:41:31.689 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:41:31.689 CNTRLR [Node 007] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:41:31.690 SERIAL » [ACK] (0x06) 17:41:31.691 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:41:31.932 SERIAL « 0x0110000400070a7105000000ff0708000062 (18 bytes) 17:41:31.933 SERIAL » [ACK] (0x06) 17:41:31.934 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 17:41:31.940 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 8 17:41:32.385 SERIAL « 0x01090004001003260300c4 (11 bytes) 17:41:32.386 CNTRLR [Node 016] [~] [Multilevel Switch] currentValue: 99 => 0 [Endpoint 0] 17:41:32.387 SERIAL » [ACK] (0x06) 17:41:32.389 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 0 17:41:32.429 SERIAL « 0x010c0004001006310504220000f3 (14 bytes) 17:41:32.430 CNTRLR [Node 016] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:32.431 CNTRLR [Node 016] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 17:41:32.432 SERIAL » [ACK] (0x06) 17:41:32.434 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:41:34.825 SERIAL » 0x010a00130c0326010025e50e (12 bytes) 17:41:34.826 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 229 └─[MultilevelSwitchCCSet] target value: 0 17:41:34.828 SERIAL « [ACK] (0x06) 17:41:34.834 SERIAL « 0x0104011301e8 (6 bytes) 17:41:34.834 SERIAL » [ACK] (0x06) 17:41:34.835 DRIVER « [RES] [SendData] was sent: true 17:41:34.852 SERIAL « 0x01070013e50000020c (9 bytes) 17:41:34.852 SERIAL » [ACK] (0x06) 17:41:34.852 DRIVER « [REQ] [SendData] callback id: 229 transmit status: OK 17:41:34.860 SERIAL » 0x010900130c02260225e60c (11 bytes) 17:41:34.860 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 230 └─[MultilevelSwitchCCGet] 17:41:34.862 SERIAL « [ACK] (0x06) 17:41:34.868 SERIAL « 0x0104011301e8 (6 bytes) 17:41:34.868 SERIAL » [ACK] (0x06) 17:41:34.869 DRIVER « [RES] [SendData] was sent: true 17:41:34.885 SERIAL « 0x01070013e60000020f (9 bytes) 17:41:34.886 SERIAL » [ACK] (0x06) 17:41:34.886 DRIVER « [REQ] [SendData] callback id: 230 transmit status: OK 17:41:34.895 SERIAL « 0x01090004000c03260363bb (11 bytes) 17:41:34.896 CNTRLR [Node 012] [~] [Multilevel Switch] currentValue: 99 => 99 [Endpoint 0] 17:41:34.897 SERIAL » [ACK] (0x06) 17:41:34.898 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 99 17:41:36.020 SERIAL « 0x010c0004000c06310504220445ae (14 bytes) 17:41:36.021 CNTRLR [Node 012] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:36.021 CNTRLR [Node 012] [~] [Multilevel Sensor] Power: 0 => 109.3 [Endpoint 0] 17:41:36.021 SERIAL » [ACK] (0x06) 17:41:36.022 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 109.3 17:41:37.854 SERIAL « 0x01090004001b033003ff26 (11 bytes) 17:41:37.855 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:41:37.856 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:41:37.857 SERIAL » [ACK] (0x06) 17:41:37.859 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:41:37.908 SERIAL « 0x01090004001b032001ff34 (11 bytes) 17:41:37.909 SERIAL » [ACK] (0x06) 17:41:37.910 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:41:37.912 CNTRLR [Node 027] treating BasicCC Set as a report 17:41:37.913 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:41:38.242 SERIAL « 0x010c0004001406310504220000f7 (14 bytes) 17:41:38.243 CNTRLR [Node 020] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:38.244 CNTRLR [Node 020] [~] [Multilevel Sensor] Power: 152.1 => 0 [Endpoint 0] 17:41:38.245 SERIAL » [ACK] (0x06) 17:41:38.247 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:41:39.445 SERIAL « 0x01090004001403260300c0 (11 bytes) 17:41:39.447 CNTRLR [Node 020] [~] [Multilevel Switch] currentValue: 99 => 0 [Endpoint 0] 17:41:39.452 SERIAL » [ACK] (0x06) 17:41:39.454 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 0 17:41:39.553 SERIAL « 0x010c0004001406310504220000f7 (14 bytes) 17:41:39.554 CNTRLR [Node 020] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:39.555 CNTRLR [Node 020] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 17:41:39.556 SERIAL » [ACK] (0x06) 17:41:39.558 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:41:40.304 SERIAL « 0x01090004001303260300c7 (11 bytes) 17:41:40.305 CNTRLR [Node 019] [~] [Multilevel Switch] currentValue: 99 => 0 [Endpoint 0] 17:41:40.306 SERIAL » [ACK] (0x06) 17:41:40.307 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 0 17:41:40.324 SERIAL « 0x010c0004001306310504220000f0 (14 bytes) 17:41:40.334 CNTRLR [Node 019] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:40.335 CNTRLR [Node 019] [~] [Multilevel Sensor] Power: 136.3 => 0 [Endpoint 0] 17:41:40.336 SERIAL » [ACK] (0x06) 17:41:40.338 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:41:41.632 SERIAL » 0x010a00130c0326012725e72b (12 bytes) 17:41:41.633 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 231 └─[MultilevelSwitchCCSet] target value: 39.6 17:41:41.635 SERIAL « [ACK] (0x06) 17:41:41.643 SERIAL « 0x0104011301e8 (6 bytes) 17:41:41.643 SERIAL » [ACK] (0x06) 17:41:41.644 DRIVER « [RES] [SendData] was sent: true 17:41:41.659 SERIAL « 0x01070013e70000030f (9 bytes) 17:41:41.659 SERIAL » [ACK] (0x06) 17:41:41.660 DRIVER « [REQ] [SendData] callback id: 231 transmit status: OK 17:41:41.673 SERIAL » 0x010a00130d0326012725e825 (12 bytes) 17:41:41.673 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 232 └─[MultilevelSwitchCCSet] target value: 39.6 17:41:41.680 SERIAL « [ACK] (0x06) 17:41:41.696 SERIAL « 0x0104011301e8 (6 bytes) 17:41:41.697 SERIAL » [ACK] (0x06) 17:41:41.698 DRIVER « [RES] [SendData] was sent: true 17:41:41.728 SERIAL « 0x01070013e800000506 (9 bytes) 17:41:41.729 SERIAL » [ACK] (0x06) 17:41:41.729 DRIVER « [REQ] [SendData] callback id: 232 transmit status: OK 17:41:41.736 SERIAL » 0x010a0013140326012725e93d (12 bytes) 17:41:41.736 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 233 └─[MultilevelSwitchCCSet] target value: 39.6 17:41:41.739 SERIAL « [ACK] (0x06) 17:41:41.744 SERIAL « 0x0104011301e8 (6 bytes) 17:41:41.745 SERIAL » [ACK] (0x06) 17:41:41.745 DRIVER « [RES] [SendData] was sent: true 17:41:41.842 SERIAL « 0x01070013e900000a08 (9 bytes) 17:41:41.842 SERIAL » [ACK] (0x06) 17:41:41.843 DRIVER « [REQ] [SendData] callback id: 233 transmit status: OK 17:41:41.847 SERIAL » 0x010900130c02260225ea00 (11 bytes) 17:41:41.847 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 234 └─[MultilevelSwitchCCGet] 17:41:41.850 SERIAL « [ACK] (0x06) 17:41:41.855 SERIAL « 0x0104011301e8 (6 bytes) 17:41:41.855 SERIAL » [ACK] (0x06) 17:41:41.856 DRIVER « [RES] [SendData] was sent: true 17:41:41.872 SERIAL « 0x01070013ea00000203 (9 bytes) 17:41:41.872 SERIAL » [ACK] (0x06) 17:41:41.873 DRIVER « [REQ] [SendData] callback id: 234 transmit status: OK 17:41:41.882 SERIAL « 0x01090004000c03260332ea (11 bytes) 17:41:41.883 CNTRLR [Node 012] [~] [Multilevel Switch] currentValue: 99 => 50 [Endpoint 0] 17:41:41.883 SERIAL » [ACK] (0x06) 17:41:41.884 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 50 17:41:41.887 SERIAL » 0x010900131402260225eb19 (11 bytes) 17:41:41.887 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 235 └─[MultilevelSwitchCCGet] 17:41:41.889 SERIAL « [ACK] (0x06) 17:41:41.895 SERIAL « 0x0104011301e8 (6 bytes) 17:41:41.896 SERIAL » [ACK] (0x06) 17:41:41.896 DRIVER « [RES] [SendData] was sent: true 17:41:41.992 SERIAL « 0x01070013eb00000a0a (9 bytes) 17:41:41.992 SERIAL » [ACK] (0x06) 17:41:41.993 DRIVER « [REQ] [SendData] callback id: 235 transmit status: OK 17:41:42.131 SERIAL « 0x01090004001403260300c0 (11 bytes) 17:41:42.132 CNTRLR [Node 020] [~] [Multilevel Switch] currentValue: 0 => 0 [Endpoint 0] 17:41:42.133 SERIAL » [ACK] (0x06) 17:41:42.133 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 0 17:41:42.137 SERIAL » 0x010a00130e0326012725ec22 (12 bytes) 17:41:42.137 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 236 └─[MultilevelSwitchCCSet] target value: 39.6 17:41:42.142 SERIAL « [ACK] (0x06) 17:41:42.148 SERIAL « 0x0104011301e8 (6 bytes) 17:41:42.148 SERIAL » [ACK] (0x06) 17:41:42.149 DRIVER « [RES] [SendData] was sent: true 17:41:42.222 SERIAL « 0x01070013ec0000080f (9 bytes) 17:41:42.223 SERIAL » [ACK] (0x06) 17:41:42.223 DRIVER « [REQ] [SendData] callback id: 236 transmit status: OK 17:41:42.227 SERIAL » 0x010a0013100326012725ed3d (12 bytes) 17:41:42.227 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 237 └─[MultilevelSwitchCCSet] target value: 39.6 17:41:42.230 SERIAL « [ACK] (0x06) 17:41:42.235 SERIAL « 0x0104011301e8 (6 bytes) 17:41:42.236 SERIAL » [ACK] (0x06) 17:41:42.236 DRIVER « [RES] [SendData] was sent: true 17:41:42.274 SERIAL « 0x01070013ed00000402 (9 bytes) 17:41:42.274 SERIAL » [ACK] (0x06) 17:41:42.275 DRIVER « [REQ] [SendData] callback id: 237 transmit status: OK 17:41:42.281 SERIAL » 0x010a0013130326012725ee3d (12 bytes) 17:41:42.281 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 238 └─[MultilevelSwitchCCSet] target value: 39.6 17:41:42.285 SERIAL « [ACK] (0x06) 17:41:42.289 SERIAL « 0x0104011301e8 (6 bytes) 17:41:42.289 SERIAL » [ACK] (0x06) 17:41:42.290 DRIVER « [RES] [SendData] was sent: true 17:41:42.306 SERIAL « 0x01070013ee00000306 (9 bytes) 17:41:42.307 SERIAL » [ACK] (0x06) 17:41:42.307 DRIVER « [REQ] [SendData] callback id: 238 transmit status: OK 17:41:42.311 SERIAL » 0x010a00131a0326012725ef35 (12 bytes) 17:41:42.312 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 239 └─[MultilevelSwitchCCSet] target value: 39.6 17:41:42.314 SERIAL « [ACK] (0x06) 17:41:42.319 SERIAL « 0x0104011301e8 (6 bytes) 17:41:42.320 SERIAL » [ACK] (0x06) 17:41:42.320 DRIVER « [RES] [SendData] was sent: true 17:41:42.358 SERIAL « 0x01070013ef00000501 (9 bytes) 17:41:42.358 SERIAL » [ACK] (0x06) 17:41:42.358 DRIVER « [REQ] [SendData] callback id: 239 transmit status: OK 17:41:42.365 SERIAL » 0x010900130d02260225f01b (11 bytes) 17:41:42.366 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 240 └─[MultilevelSwitchCCGet] 17:41:42.368 SERIAL « [ACK] (0x06) 17:41:42.373 SERIAL « 0x0104011301e8 (6 bytes) 17:41:42.374 SERIAL » [ACK] (0x06) 17:41:42.374 DRIVER « [RES] [SendData] was sent: true 17:41:42.420 SERIAL « 0x01070013f00000051e (9 bytes) 17:41:42.420 SERIAL » [ACK] (0x06) 17:41:42.421 DRIVER « [REQ] [SendData] callback id: 240 transmit status: OK 17:41:42.470 SERIAL « 0x01090004000d03260300d9 (11 bytes) 17:41:42.472 CNTRLR [Node 013] [~] [Multilevel Switch] currentValue: 0 => 0 [Endpoint 0] 17:41:42.473 SERIAL » [ACK] (0x06) 17:41:42.475 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 0 17:41:42.482 SERIAL » 0x010900130e02260225f119 (11 bytes) 17:41:42.483 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 241 └─[MultilevelSwitchCCGet] 17:41:42.487 SERIAL « [ACK] (0x06) 17:41:42.492 SERIAL « 0x0104011301e8 (6 bytes) 17:41:42.493 SERIAL » [ACK] (0x06) 17:41:42.494 DRIVER « [RES] [SendData] was sent: true 17:41:42.563 SERIAL « 0x01070013f100000812 (9 bytes) 17:41:42.563 SERIAL » [ACK] (0x06) 17:41:42.564 DRIVER « [REQ] [SendData] callback id: 241 transmit status: OK 17:41:42.575 SERIAL « 0x01090004000e03260300da (11 bytes) 17:41:42.576 CNTRLR [Node 014] [~] [Multilevel Switch] currentValue: 0 => 0 [Endpoint 0] 17:41:42.577 SERIAL » [ACK] (0x06) 17:41:42.579 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 0 17:41:42.584 SERIAL » 0x010900131002260225f204 (11 bytes) 17:41:42.585 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 242 └─[MultilevelSwitchCCGet] 17:41:42.589 SERIAL « [ACK] (0x06) 17:41:42.593 SERIAL « 0x0104011301e8 (6 bytes) 17:41:42.593 SERIAL » [ACK] (0x06) 17:41:42.594 DRIVER « [RES] [SendData] was sent: true 17:41:42.631 SERIAL « 0x01070013f20000041d (9 bytes) 17:41:42.631 SERIAL » [ACK] (0x06) 17:41:42.632 DRIVER « [REQ] [SendData] callback id: 242 transmit status: OK 17:41:42.678 SERIAL « 0x01090004001003260300c4 (11 bytes) 17:41:42.678 CNTRLR [Node 016] [~] [Multilevel Switch] currentValue: 0 => 0 [Endpoint 0] 17:41:42.679 SERIAL » [ACK] (0x06) 17:41:42.680 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 0 17:41:42.683 SERIAL » 0x010900131302260225f306 (11 bytes) 17:41:42.683 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 243 └─[MultilevelSwitchCCGet] 17:41:42.685 SERIAL « [ACK] (0x06) 17:41:42.691 SERIAL « 0x0104011301e8 (6 bytes) 17:41:42.691 SERIAL » [ACK] (0x06) 17:41:42.692 DRIVER « [RES] [SendData] was sent: true 17:41:42.762 SERIAL « 0x01070013f300000810 (9 bytes) 17:41:42.763 SERIAL » [ACK] (0x06) 17:41:42.763 DRIVER « [REQ] [SendData] callback id: 243 transmit status: OK 17:41:42.773 SERIAL « 0x01090004001303260300c7 (11 bytes) 17:41:42.773 CNTRLR [Node 019] [~] [Multilevel Switch] currentValue: 0 => 0 [Endpoint 0] 17:41:42.774 SERIAL » [ACK] (0x06) 17:41:42.775 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 0 17:41:42.778 SERIAL » 0x010900131a02260225f408 (11 bytes) 17:41:42.779 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 244 └─[MultilevelSwitchCCGet] 17:41:42.781 SERIAL « [ACK] (0x06) 17:41:42.787 SERIAL « 0x0104011301e8 (6 bytes) 17:41:42.787 SERIAL » [ACK] (0x06) 17:41:42.788 DRIVER « [RES] [SendData] was sent: true 17:41:42.867 SERIAL « 0x010c0004000d0631050422064aa2 (14 bytes) 17:41:42.867 CNTRLR [Node 013] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:42.868 CNTRLR [Node 013] [~] [Multilevel Sensor] Power: 0 => 161 [Endpoint 0] 17:41:42.868 SERIAL » [ACK] (0x06) 17:41:42.869 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 161 17:41:43.134 SERIAL « 0x01070013f40000233c (9 bytes) 17:41:43.134 SERIAL » [ACK] (0x06) 17:41:43.135 DRIVER « [REQ] [SendData] callback id: 244 transmit status: OK 17:41:43.229 SERIAL « 0x010c00040014063105042205fd0f (14 bytes) 17:41:43.230 CNTRLR [Node 020] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:43.230 CNTRLR [Node 020] [~] [Multilevel Sensor] Power: 0 => 153.3 [Endpoint 0] 17:41:43.230 SERIAL » [ACK] (0x06) 17:41:43.231 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 153.3 17:41:43.361 SERIAL « 0x010c0004000e063105042205b65e (14 bytes) 17:41:43.363 CNTRLR [Node 014] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:43.371 CNTRLR [Node 014] [~] [Multilevel Sensor] Power: 0 => 146.2 [Endpoint 0] 17:41:43.372 SERIAL » [ACK] (0x06) 17:41:43.374 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 146.2 17:41:43.427 SERIAL « 0x010c0004100d0631050422064ab2 (14 bytes) 17:41:43.428 CNTRLR [Node 013] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:43.430 CNTRLR [Node 013] [~] [Multilevel Sensor] Power: 161 => 161 [Endpoint 0] 17:41:43.431 SERIAL » [ACK] (0x06) 17:41:43.432 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 161 17:41:43.436 SERIAL « 0x01090004000c03260327ff (11 bytes) 17:41:43.437 CNTRLR [Node 012] [~] [Multilevel Switch] currentValue: 50 => 39 [Endpoint 0] 17:41:43.438 SERIAL » [ACK] (0x06) 17:41:43.440 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 39 17:41:43.445 SERIAL « 0x010c000400130631050422055da8 (14 bytes) 17:41:43.447 CNTRLR [Node 019] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:43.448 CNTRLR [Node 019] [~] [Multilevel Sensor] Power: 0 => 137.3 [Endpoint 0] 17:41:43.448 SERIAL » [ACK] (0x06) 17:41:43.450 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 137.3 17:41:43.524 SERIAL « 0x010c0004100d0631050422064ab2 (14 bytes) 17:41:43.525 CNTRLR [Node 013] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:43.526 CNTRLR [Node 013] [~] [Multilevel Sensor] Power: 161 => 161 [Endpoint 0] 17:41:43.527 SERIAL » [ACK] (0x06) 17:41:43.528 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 161 17:41:43.567 SERIAL « 0x010c0004100d0631050422064ab2 (14 bytes) 17:41:43.568 CNTRLR [Node 013] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:43.568 CNTRLR [Node 013] [~] [Multilevel Sensor] Power: 161 => 161 [Endpoint 0] 17:41:43.569 SERIAL » [ACK] (0x06) 17:41:43.570 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 161 17:41:43.605 SERIAL « 0x010c0004100d0631050422064ab2 (14 bytes) 17:41:43.606 CNTRLR [Node 013] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:43.607 CNTRLR [Node 013] [~] [Multilevel Sensor] Power: 161 => 161 [Endpoint 0] 17:41:43.607 SERIAL » [ACK] (0x06) 17:41:43.609 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 161 17:41:43.665 SERIAL « 0x010c0004100d0631050422064ab2 (14 bytes) 17:41:43.666 CNTRLR [Node 013] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:43.667 CNTRLR [Node 013] [~] [Multilevel Sensor] Power: 161 => 161 [Endpoint 0] 17:41:43.668 SERIAL » [ACK] (0x06) 17:41:43.669 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 161 17:41:43.731 SERIAL « 0x010c0004000c06310504220000ef (14 bytes) 17:41:43.732 CNTRLR [Node 012] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:43.733 CNTRLR [Node 012] [~] [Multilevel Sensor] Power: 109.3 => 0 [Endpoint 0] 17:41:43.734 SERIAL » [ACK] (0x06) 17:41:43.735 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:41:43.750 SERIAL « 0x010c0004100d0631050422064ab2 (14 bytes) 17:41:43.751 CNTRLR [Node 013] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:43.752 CNTRLR [Node 013] [~] [Multilevel Sensor] Power: 161 => 161 [Endpoint 0] 17:41:43.753 SERIAL » [ACK] (0x06) 17:41:43.755 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 161 17:41:43.796 SERIAL « 0x010c0004100d0631050422064ab2 (14 bytes) 17:41:43.797 CNTRLR [Node 013] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:43.798 CNTRLR [Node 013] [~] [Multilevel Sensor] Power: 161 => 161 [Endpoint 0] 17:41:43.798 SERIAL » [ACK] (0x06) 17:41:43.800 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 161 17:41:43.836 SERIAL « 0x010c0004101a0631050422077896 (14 bytes) 17:41:43.837 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:43.838 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 0 => 191.2 [Endpoint 0] 17:41:43.839 SERIAL » [ACK] (0x06) 17:41:43.841 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 191.2 17:41:43.860 SERIAL « 0x010c0004100d0631050422064ab2 (14 bytes) 17:41:43.861 CNTRLR [Node 013] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:43.862 CNTRLR [Node 013] [~] [Multilevel Sensor] Power: 161 => 161 [Endpoint 0] 17:41:43.863 SERIAL » [ACK] (0x06) 17:41:43.865 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 161 17:41:43.868 SERIAL « 0x010c0004101a0631050422077896 (14 bytes) 17:41:43.869 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:43.870 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 191.2 => 191.2 [Endpoint 0] 17:41:43.871 SERIAL » [ACK] (0x06) 17:41:43.873 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 191.2 17:41:43.925 SERIAL « 0x010c0004101a0631050422077896 (14 bytes) 17:41:43.927 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:43.928 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 191.2 => 191.2 [Endpoint 0] 17:41:43.928 SERIAL » [ACK] (0x06) 17:41:43.930 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 191.2 17:41:43.988 SERIAL « 0x010c0004101a0631050422077896 (14 bytes) 17:41:43.989 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:43.989 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 191.2 => 191.2 [Endpoint 0] 17:41:43.990 SERIAL » [ACK] (0x06) 17:41:43.991 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 191.2 17:41:44.125 SERIAL « 0x010c0004101a0631050422077896 (14 bytes) 17:41:44.126 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:44.126 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 191.2 => 191.2 [Endpoint 0] 17:41:44.127 SERIAL » [ACK] (0x06) 17:41:44.128 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 191.2 17:41:44.188 SERIAL « 0x010c0004101a0631050422077896 (14 bytes) 17:41:44.189 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:44.190 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 191.2 => 191.2 [Endpoint 0] 17:41:44.191 SERIAL » [ACK] (0x06) 17:41:44.192 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 191.2 17:41:44.263 SERIAL « 0x010c0004101a0631050422077896 (14 bytes) 17:41:44.269 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:44.270 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 191.2 => 191.2 [Endpoint 0] 17:41:44.271 SERIAL » [ACK] (0x06) 17:41:44.273 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 191.2 17:41:44.328 SERIAL « 0x010c0004101a0631050422077896 (14 bytes) 17:41:44.329 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:44.330 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 191.2 => 191.2 [Endpoint 0] 17:41:44.331 SERIAL » [ACK] (0x06) 17:41:44.332 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 191.2 17:41:44.457 SERIAL « 0x010c0004101a0631050422077896 (14 bytes) 17:41:44.458 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:44.459 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 191.2 => 191.2 [Endpoint 0] 17:41:44.460 SERIAL » [ACK] (0x06) 17:41:44.462 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 191.2 17:41:44.535 SERIAL « 0x010c0004101a0631050422077896 (14 bytes) 17:41:44.537 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:44.538 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 191.2 => 191.2 [Endpoint 0] 17:41:44.539 SERIAL » [ACK] (0x06) 17:41:44.541 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 191.2 17:41:44.738 CNTRLR [Node 026] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 17:41:45.241 SERIAL » 0x010900131a02260225f408 (11 bytes) 17:41:45.242 DRIVER » [Node 026] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 244 └─[MultilevelSwitchCCGet] 17:41:45.243 SERIAL « [ACK] (0x06) 17:41:45.250 SERIAL « 0x0104011301e8 (6 bytes) 17:41:45.250 SERIAL » [ACK] (0x06) 17:41:45.251 DRIVER « [RES] [SendData] was sent: true 17:41:45.312 SERIAL « 0x01070013f400000718 (9 bytes) 17:41:45.312 SERIAL » [ACK] (0x06) 17:41:45.313 DRIVER « [REQ] [SendData] callback id: 244 transmit status: OK 17:41:45.360 SERIAL « 0x01090004001a0326035a94 (11 bytes) 17:41:45.360 CNTRLR [Node 026] [~] [Multilevel Switch] currentValue: 99 => 90 [Endpoint 0] 17:41:45.361 SERIAL » [ACK] (0x06) 17:41:45.362 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 90 17:41:49.208 SERIAL « 0x01090004001403260327e7 (11 bytes) 17:41:49.209 CNTRLR [Node 020] [~] [Multilevel Switch] currentValue: 0 => 39 [Endpoint 0] 17:41:49.210 SERIAL » [ACK] (0x06) 17:41:49.211 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 39 17:41:49.315 SERIAL « 0x010c0004001406310504220000f7 (14 bytes) 17:41:49.316 CNTRLR [Node 020] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:49.317 CNTRLR [Node 020] [~] [Multilevel Sensor] Power: 153.3 => 0 [Endpoint 0] 17:41:49.318 SERIAL » [ACK] (0x06) 17:41:49.319 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:41:49.412 SERIAL « 0x01090004000d03260327fe (11 bytes) 17:41:49.413 CNTRLR [Node 013] [~] [Multilevel Switch] currentValue: 0 => 39 [Endpoint 0] 17:41:49.414 SERIAL » [ACK] (0x06) 17:41:49.415 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 39 17:41:49.456 SERIAL « 0x010c0004000d06310504220000ee (14 bytes) 17:41:49.457 CNTRLR [Node 013] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:49.460 CNTRLR [Node 013] [~] [Multilevel Sensor] Power: 161 => 0 [Endpoint 0] 17:41:49.463 SERIAL » [ACK] (0x06) 17:41:49.467 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:41:49.800 SERIAL « 0x01090004001303260327e0 (11 bytes) 17:41:49.801 CNTRLR [Node 019] [~] [Multilevel Switch] currentValue: 0 => 39 [Endpoint 0] 17:41:49.802 SERIAL » [ACK] (0x06) 17:41:49.802 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 39 17:41:49.820 SERIAL « 0x010c0004001306310504220000f0 (14 bytes) 17:41:49.820 CNTRLR [Node 019] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:49.821 CNTRLR [Node 019] [~] [Multilevel Sensor] Power: 137.3 => 0 [Endpoint 0] 17:41:49.821 SERIAL » [ACK] (0x06) 17:41:49.822 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:41:49.868 SERIAL « 0x01090004000703300300c5 (11 bytes) 17:41:49.869 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:41:49.869 CNTRLR [Node 007] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:41:49.870 SERIAL » [ACK] (0x06) 17:41:49.870 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:41:50.112 SERIAL « 0x0110000400070a7105000000ff070000006a (18 bytes) 17:41:50.112 SERIAL » [ACK] (0x06) 17:41:50.113 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) 17:41:50.132 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 17:41:50.180 SERIAL « 0x01090004001003260327e3 (11 bytes) 17:41:50.180 CNTRLR [Node 016] [~] [Multilevel Switch] currentValue: 0 => 39 [Endpoint 0] 17:41:50.181 SERIAL » [ACK] (0x06) 17:41:50.182 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 39 17:41:50.233 SERIAL « 0x010c0004001006310504220000f3 (14 bytes) 17:41:50.234 CNTRLR [Node 016] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:50.236 CNTRLR [Node 016] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 17:41:50.236 SERIAL » [ACK] (0x06) 17:41:50.238 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:41:52.814 SERIAL « 0x01090004000e03260327fd (11 bytes) 17:41:52.814 CNTRLR [Node 014] [~] [Multilevel Switch] currentValue: 0 => 39 [Endpoint 0] 17:41:52.815 SERIAL » [ACK] (0x06) 17:41:52.816 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 39 17:41:52.833 SERIAL « 0x010c0004000e06310504220000ed (14 bytes) 17:41:52.834 CNTRLR [Node 014] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:52.834 CNTRLR [Node 014] [~] [Multilevel Sensor] Power: 146.2 => 0 [Endpoint 0] 17:41:52.834 SERIAL » [ACK] (0x06) 17:41:52.835 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:41:54.871 SERIAL « 0x01090004000803300300ca (11 bytes) 17:41:54.872 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:41:54.872 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:41:54.873 SERIAL » [ACK] (0x06) 17:41:54.874 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:41:54.945 SERIAL « 0x01090004000803200100d8 (11 bytes) 17:41:54.955 SERIAL » [ACK] (0x06) 17:41:54.955 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:41:54.957 CNTRLR [Node 008] treating BasicCC Set as a report 17:41:54.957 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:41:55.678 SERIAL « 0x01090004001503300300d7 (11 bytes) 17:41:55.678 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:41:55.679 CNTRLR [Node 021] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:41:55.679 SERIAL » [ACK] (0x06) 17:41:55.680 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:41:55.732 SERIAL « 0x01090004001503200100c5 (11 bytes) 17:41:55.732 SERIAL » [ACK] (0x06) 17:41:55.733 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:41:55.734 CNTRLR [Node 021] treating BasicCC Set as a report 17:41:55.734 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:41:57.446 SERIAL « 0x01090004001a03260327e9 (11 bytes) 17:41:57.447 CNTRLR [Node 026] [~] [Multilevel Switch] currentValue: 90 => 39 [Endpoint 0] 17:41:57.448 SERIAL » [ACK] (0x06) 17:41:57.449 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 39 17:41:57.516 SERIAL « 0x010c0004001a06310504220000f9 (14 bytes) 17:41:57.517 CNTRLR [Node 026] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:57.518 CNTRLR [Node 026] [~] [Multilevel Sensor] Power: 191.2 => 0 [Endpoint 0] 17:41:57.519 SERIAL » [ACK] (0x06) 17:41:57.521 DRIVER « [Node 026] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 17:41:59.982 SERIAL « 0x010c00040003063105042209937a (14 bytes) 17:41:59.983 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:41:59.984 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 114.7 => 245.1 [Endpoint 0] 17:41:59.984 SERIAL » [ACK] (0x06) 17:41:59.985 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 245.1 17:42:00.983 SERIAL « 0x010c00040003063105042206e402 (14 bytes) 17:42:00.985 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:42:00.986 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 245.1 => 176.4 [Endpoint 0] 17:42:00.988 SERIAL » [ACK] (0x06) 17:42:00.989 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 176.4 17:42:01.982 SERIAL « 0x010c000400030631050422041ffb (14 bytes) 17:42:01.983 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:42:01.984 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 176.4 => 105.5 [Endpoint 0] 17:42:01.984 SERIAL » [ACK] (0x06) 17:42:01.985 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 105.5 17:42:02.983 SERIAL « 0x010c00040003063105042208ca22 (14 bytes) 17:42:02.985 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:42:02.986 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 105.5 => 225 [Endpoint 0] 17:42:02.987 SERIAL » [ACK] (0x06) 17:42:02.990 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 225 17:42:03.983 SERIAL « 0x010c000400030631050422032ac9 (14 bytes) 17:42:03.984 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:42:03.984 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 225 => 81 [Endpoint 0] 17:42:03.985 SERIAL » [ACK] (0x06) 17:42:03.986 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 81 17:42:06.039 SERIAL « 0x0110000400140a32022144000000fe00005e (18 bytes) 17:42:06.040 CNTRLR [Node 020] [~] [Meter] value[65537]: 2.54 => 2.54 [Endpoint 0] 17:42:06.041 CNTRLR [Node 020] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 17:42:06.041 SERIAL » [ACK] (0x06) 17:42:06.043 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 2.54 time delta: 0 seconds 17:42:06.120 SERIAL « 0x010c0004000306310504220623c5 (14 bytes) 17:42:06.120 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:42:06.121 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 81 => 157.1 [Endpoint 0] 17:42:06.121 SERIAL » [ACK] (0x06) 17:42:06.122 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 157.1 17:42:08.531 SERIAL « 0x01090004001e03300300dc (11 bytes) 17:42:08.532 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:42:08.533 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:42:08.534 SERIAL » [ACK] (0x06) 17:42:08.536 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:42:08.585 SERIAL « 0x01090004001e03200100ce (11 bytes) 17:42:08.586 SERIAL » [ACK] (0x06) 17:42:08.587 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:42:08.588 CNTRLR [Node 030] treating BasicCC Set as a report 17:42:08.588 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:42:16.984 SERIAL « 0x010c000400030631050422047f9b (14 bytes) 17:42:16.986 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:42:16.987 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 157.1 => 115.1 [Endpoint 0] 17:42:16.988 SERIAL » [ACK] (0x06) 17:42:16.991 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 115.1 17:42:19.984 SERIAL « 0x010c0004000306310504220934dd (14 bytes) 17:42:19.985 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:42:19.985 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 115.1 => 235.6 [Endpoint 0] 17:42:19.986 SERIAL » [ACK] (0x06) 17:42:19.987 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 235.6 17:42:20.985 SERIAL « 0x010c000400030631050422038d6e (14 bytes) 17:42:20.986 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:42:20.986 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 235.6 => 90.9 [Endpoint 0] 17:42:20.987 SERIAL » [ACK] (0x06) 17:42:20.988 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 90.9 17:42:21.985 SERIAL « 0x010c000400030631050422047490 (14 bytes) 17:42:21.986 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:42:21.987 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 90.9 => 114 [Endpoint 0] 17:42:21.988 SERIAL » [ACK] (0x06) 17:42:21.990 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 114 17:42:33.986 SERIAL « 0x010c000400030631050422080ae2 (14 bytes) 17:42:33.986 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:42:33.987 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 114 => 205.8 [Endpoint 0] 17:42:33.987 SERIAL » [ACK] (0x06) 17:42:33.988 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 205.8 17:42:41.635 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 17:42:41.636 SERIAL » [ACK] (0x06) 17:42:41.637 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  17:42:41.639 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 17:42:47.987 SERIAL « 0x010c000400030631050422046c88 (14 bytes) 17:42:47.989 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:42:47.990 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 205.8 => 113.2 [Endpoint 0] 17:42:47.991 SERIAL » [ACK] (0x06) 17:42:47.995 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 113.2 17:42:51.798 SERIAL « 0x010c00040002063105030a0014da (14 bytes) 17:42:51.800 CNTRLR [Node 002] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 17:42:51.801 CNTRLR [Node 002] [~] [Multilevel Sensor] Illuminance: 20 => 20 [Endpoint 0] 17:42:51.802 SERIAL » [ACK] (0x06) 17:42:51.803 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 20 17:42:56.769 SERIAL « 0x01090004001b03300300d9 (11 bytes) 17:42:56.769 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:42:56.770 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:42:56.771 SERIAL » [ACK] (0x06) 17:42:56.772 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:42:56.823 SERIAL « 0x01090004001b03200100cb (11 bytes) 17:42:56.824 SERIAL » [ACK] (0x06) 17:42:56.825 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:42:56.827 CNTRLR [Node 027] treating BasicCC Set as a report 17:42:56.827 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:43:00.059 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:43:00.060 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:43:00.060 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:43:00.061 SERIAL » [ACK] (0x06) 17:43:00.061 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:43:00.127 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:43:00.128 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:43:00.128 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:43:00.129 SERIAL » [ACK] (0x06) 17:43:00.129 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:43:00.143 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:43:00.144 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:43:00.144 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:43:00.145 SERIAL » [ACK] (0x06) 17:43:00.155 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:43:00.158 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:43:00.159 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:43:00.159 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:43:00.160 SERIAL » [ACK] (0x06) 17:43:00.161 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:43:00.207 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:43:00.208 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:43:00.209 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:43:00.209 SERIAL » [ACK] (0x06) 17:43:00.210 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:43:00.276 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:43:00.277 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:43:00.277 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:43:00.278 SERIAL » [ACK] (0x06) 17:43:00.279 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:43:00.328 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:43:00.329 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:43:00.329 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:43:00.329 SERIAL » [ACK] (0x06) 17:43:00.330 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:43:00.376 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:43:00.377 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:43:00.377 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:43:00.378 SERIAL » [ACK] (0x06) 17:43:00.378 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:43:00.427 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:43:00.427 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:43:00.432 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:43:00.432 SERIAL » [ACK] (0x06) 17:43:00.433 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:43:00.444 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:43:00.445 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:43:00.445 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:43:00.446 SERIAL » [ACK] (0x06) 17:43:00.447 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:43:00.490 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:43:00.490 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:43:00.491 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:43:00.491 SERIAL » [ACK] (0x06) 17:43:00.492 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:43:00.537 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:43:00.538 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:43:00.538 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:43:00.539 SERIAL » [ACK] (0x06) 17:43:00.540 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:43:58.259 SERIAL « 0x01080004102002840742 (10 bytes) 17:43:58.260 SERIAL » [ACK] (0x06) 17:43:58.261 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:43:58.263 CNTRLR « [Node 032] received wakeup notification 17:43:58.264 CNTRLR [Node 032] The node is now awake. 17:43:58.276 SERIAL » 0x010900132002840525f596 (11 bytes) 17:43:58.276 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 245 └─[WakeUpCCIntervalGet] 17:43:58.282 SERIAL « [ACK] (0x06) 17:43:58.285 SERIAL « 0x0104011301e8 (6 bytes) 17:43:58.286 SERIAL » [ACK] (0x06) 17:43:58.289 DRIVER « [RES] [SendData] was sent: true 17:43:58.324 SERIAL « 0x01070013f50000041a (9 bytes) 17:43:58.325 SERIAL » [ACK] (0x06) 17:43:58.326 DRIVER « [REQ] [SendData] callback id: 245 transmit status: OK 17:43:58.372 SERIAL « 0x010c0004002006840600038401d5 (14 bytes) 17:43:58.373 CNTRLR [Node 032] [~] [Wake Up] wakeUpInterval: 900 => 900 [Endpoint 0] 17:43:58.374 CNTRLR [Node 032] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 17:43:58.375 SERIAL » [ACK] (0x06) 17:43:58.377 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 900 seconds controller node id: 1 17:43:58.382 SERIAL « 0x01080004102002840742 (10 bytes) 17:43:58.384 SERIAL » [ACK] (0x06) 17:43:58.385 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:43:58.392 CNTRLR « [Node 032] received wakeup notification 17:43:58.551 SERIAL « 0x01080004102002840742 (10 bytes) 17:43:58.552 SERIAL » [ACK] (0x06) 17:43:58.552 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:43:58.554 CNTRLR « [Node 032] received wakeup notification 17:43:58.566 SERIAL « 0x01080004102002840742 (10 bytes) 17:43:58.567 SERIAL » [ACK] (0x06) 17:43:58.568 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:43:58.569 CNTRLR « [Node 032] received wakeup notification 17:43:58.630 SERIAL « 0x01080004102002840742 (10 bytes) 17:43:58.631 SERIAL » [ACK] (0x06) 17:43:58.631 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:43:58.632 CNTRLR « [Node 032] received wakeup notification 17:43:58.694 SERIAL « 0x01080004102002840742 (10 bytes) 17:43:58.695 SERIAL » [ACK] (0x06) 17:43:58.695 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:43:58.696 CNTRLR « [Node 032] received wakeup notification 17:43:58.789 SERIAL « 0x01080004102002840742 (10 bytes) 17:43:58.790 SERIAL » [ACK] (0x06) 17:43:58.790 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:43:58.791 CNTRLR « [Node 032] received wakeup notification 17:43:58.912 SERIAL « 0x01080004102002840742 (10 bytes) 17:43:58.912 SERIAL » [ACK] (0x06) 17:43:58.913 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:43:58.914 CNTRLR « [Node 032] received wakeup notification 17:43:58.966 SERIAL « 0x01080004102002840742 (10 bytes) 17:43:58.966 SERIAL » [ACK] (0x06) 17:43:58.967 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:43:58.968 CNTRLR « [Node 032] received wakeup notification 17:43:59.969 CNTRLR » [Node 032] Sending node back to sleep... 17:43:59.977 SERIAL » 0x010900132002840825f698 (11 bytes) 17:43:59.978 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 246 └─[WakeUpCCNoMoreInformation] 17:43:59.980 SERIAL « [ACK] (0x06) 17:43:59.986 SERIAL « 0x0104011301e8 (6 bytes) 17:43:59.987 SERIAL » [ACK] (0x06) 17:43:59.987 DRIVER « [RES] [SendData] was sent: true 17:44:00.049 SERIAL « 0x01070013f60000071a (9 bytes) 17:44:00.049 SERIAL » [ACK] (0x06) 17:44:00.049 DRIVER « [REQ] [SendData] callback id: 246 transmit status: OK 17:44:00.052 CNTRLR [Node 032] The node is now asleep. 17:44:11.996 SERIAL « 0x010c00040003063105042208ce26 (14 bytes) 17:44:11.997 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:44:11.998 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 113.2 => 225.4 [Endpoint 0] 17:44:11.999 SERIAL » [ACK] (0x06) 17:44:12.001 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 225.4 17:44:12.996 SERIAL « 0x010c000400030631050422046a8e (14 bytes) 17:44:12.997 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:44:12.998 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 225.4 => 113 [Endpoint 0] 17:44:12.998 SERIAL » [ACK] (0x06) 17:44:13.000 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 113 17:44:44.999 SERIAL « 0x010c000400030631050422086a82 (14 bytes) 17:44:45.000 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:44:45.000 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 113 => 215.4 [Endpoint 0] 17:44:45.001 SERIAL » [ACK] (0x06) 17:44:45.001 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 215.4 17:45:01.001 SERIAL « 0x010c000400030631050422068264 (14 bytes) 17:45:01.001 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:45:01.002 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 215.4 => 166.6 [Endpoint 0] 17:45:01.002 SERIAL » [ACK] (0x06) 17:45:01.003 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 166.6 17:45:05.001 SERIAL « 0x010c000400030631050422039774 (14 bytes) 17:45:05.002 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:45:05.003 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 166.6 => 91.9 [Endpoint 0] 17:45:05.004 SERIAL » [ACK] (0x06) 17:45:05.008 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 91.9 17:45:06.001 SERIAL « 0x010c000400030631050422048165 (14 bytes) 17:45:06.003 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:45:06.004 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 91.9 => 115.3 [Endpoint 0] 17:45:06.005 SERIAL » [ACK] (0x06) 17:45:06.006 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 115.3 17:45:14.002 SERIAL « 0x010c00040003063105042208a64e (14 bytes) 17:45:14.003 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:45:14.004 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 115.3 => 221.4 [Endpoint 0] 17:45:14.005 SERIAL » [ACK] (0x06) 17:45:14.007 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 221.4 17:45:15.002 SERIAL « 0x010c000400030631050422040eea (14 bytes) 17:45:15.025 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:45:15.026 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 221.4 => 103.8 [Endpoint 0] 17:45:15.026 SERIAL » [ACK] (0x06) 17:45:15.027 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 103.8 17:45:44.390 SERIAL « 0x0110000400120a600d02003105012200a52e (18 bytes) 17:45:44.393 CNTRLR [Node 018] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 17:45:44.394 CNTRLR [Node 018] [~] [Multilevel Sensor] Air temperature: 16.7 => 16.5 [Endpoint 2] 17:45:44.396 SERIAL » [ACK] (0x06) 17:45:44.398 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 16.5 17:46:02.007 SERIAL « 0x010c000400030631050422077b9c (14 bytes) 17:46:02.008 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:46:02.008 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 103.8 => 191.5 [Endpoint 0] 17:46:02.009 SERIAL » [ACK] (0x06) 17:46:02.010 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 191.5 17:46:04.008 SERIAL « 0x010c0004000306310504220624c2 (14 bytes) 17:46:04.009 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:46:04.009 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 191.5 => 157.2 [Endpoint 0] 17:46:04.010 SERIAL » [ACK] (0x06) 17:46:04.012 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 157.2 17:46:06.007 SERIAL « 0x010c000400030631050422036380 (14 bytes) 17:46:06.009 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:46:06.010 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 157.2 => 86.7 [Endpoint 0] 17:46:06.010 SERIAL » [ACK] (0x06) 17:46:06.012 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 86.7 17:46:07.007 SERIAL « 0x010c000400030631050422046f8b (14 bytes) 17:46:07.009 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:46:07.010 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 86.7 => 113.5 [Endpoint 0] 17:46:07.011 SERIAL » [ACK] (0x06) 17:46:07.012 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 113.5 17:46:40.866 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:46:40.867 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:46:40.868 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:46:40.869 SERIAL » [ACK] (0x06) 17:46:40.871 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:46:40.914 SERIAL « 0x010900040020032001ff0f (11 bytes) 17:46:40.915 SERIAL » [ACK] (0x06) 17:46:40.917 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:46:40.922 CNTRLR [Node 032] treating BasicCC Set as a report 17:46:40.926 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:46:40.956 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:46:40.957 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:46:40.958 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:46:40.959 SERIAL » [ACK] (0x06) 17:46:40.961 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:46:41.023 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:46:41.024 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:46:41.025 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:46:41.025 SERIAL » [ACK] (0x06) 17:46:41.026 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:46:41.155 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:46:41.156 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:46:41.156 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:46:41.156 SERIAL » [ACK] (0x06) 17:46:41.157 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:46:41.183 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:46:41.183 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:46:41.184 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:46:41.184 SERIAL » [ACK] (0x06) 17:46:41.185 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:46:41.237 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:46:41.238 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:46:41.239 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:46:41.239 SERIAL » [ACK] (0x06) 17:46:41.240 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:46:41.382 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:46:41.382 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:46:41.383 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:46:41.383 SERIAL » [ACK] (0x06) 17:46:41.384 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:46:41.464 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:46:41.465 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:46:41.465 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:46:41.466 SERIAL » [ACK] (0x06) 17:46:41.467 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:48:21.197 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:48:21.198 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:48:21.199 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:48:21.200 SERIAL » [ACK] (0x06) 17:48:21.202 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:48:21.255 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:48:21.257 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:48:21.258 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:48:21.259 SERIAL » [ACK] (0x06) 17:48:21.260 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:48:21.314 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:48:21.315 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:48:21.316 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:48:21.317 SERIAL » [ACK] (0x06) 17:48:21.319 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:48:21.354 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:48:21.355 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:48:21.356 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:48:21.357 SERIAL » [ACK] (0x06) 17:48:21.358 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:48:21.497 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:48:21.498 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:48:21.499 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:48:21.500 SERIAL » [ACK] (0x06) 17:48:21.501 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:48:21.580 SERIAL « 0x01090004002003200100f0 (11 bytes) 17:48:21.581 SERIAL » [ACK] (0x06) 17:48:21.582 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:48:21.584 CNTRLR [Node 032] treating BasicCC Set as a report 17:48:21.585 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:48:21.589 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:48:21.590 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:48:21.591 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:48:21.592 SERIAL » [ACK] (0x06) 17:48:21.593 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:48:21.706 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:48:21.707 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:48:21.708 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:48:21.708 SERIAL » [ACK] (0x06) 17:48:21.710 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:48:21.918 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:48:21.920 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:48:21.921 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:48:21.921 SERIAL » [ACK] (0x06) 17:48:21.923 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:49:05.062 SERIAL » 0x010e00132207600d00012501ff25f7a2 (16 bytes) 17:49:05.064 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 247 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCSet] target value: true 17:49:05.066 SERIAL « [ACK] (0x06) 17:49:05.073 SERIAL « 0x0104011301e8 (6 bytes) 17:49:05.074 SERIAL » [ACK] (0x06) 17:49:05.074 DRIVER « [RES] [SendData] was sent: true 17:49:05.095 SERIAL « 0x01070013f70000021e (9 bytes) 17:49:05.095 SERIAL » [ACK] (0x06) 17:49:05.096 DRIVER « [REQ] [SendData] callback id: 247 transmit status: OK 17:49:05.104 SERIAL » 0x010d00132206600d0001250225f853 (15 bytes) 17:49:05.105 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 248 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 17:49:05.106 SERIAL « [ACK] (0x06) 17:49:05.113 SERIAL « 0x0104011301e8 (6 bytes) 17:49:05.113 SERIAL » [ACK] (0x06) 17:49:05.114 DRIVER « [RES] [SendData] was sent: true 17:49:05.134 SERIAL « 0x01070013f800000211 (9 bytes) 17:49:05.135 SERIAL » [ACK] (0x06) 17:49:05.135 DRIVER « [REQ] [SendData] callback id: 248 transmit status: OK 17:49:05.150 SERIAL « 0x010d0004002207600d010025030099 (15 bytes) 17:49:05.152 CNTRLR [Node 034] [~] [Binary Switch] currentValue: false => false [Endpoint 1] 17:49:05.152 SERIAL » [ACK] (0x06) 17:49:05.154 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: false 17:49:05.174 SERIAL « 0x010d0004002207600d01002503ff66 (15 bytes) 17:49:05.175 CNTRLR [Node 034] [~] [Binary Switch] currentValue: false => true [Endpoint 1] 17:49:05.176 SERIAL » [ACK] (0x06) 17:49:05.177 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: true 17:49:07.155 SERIAL « 0x0112000400220c600d01003202213201c200004b (20 bytes) 17:49:07.157 CNTRLR [Node 034] [~] [Meter] value[66049]: 0 => 45 [Endpoint 1] 17:49:07.158 CNTRLR [Node 034] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 1] 17:49:07.159 SERIAL » [ACK] (0x06) 17:49:07.160 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 45 time delta: 0 seconds 17:49:59.970 SERIAL « 0x01090004001b033003ff26 (11 bytes) 17:49:59.971 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:49:59.972 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:49:59.972 SERIAL » [ACK] (0x06) 17:49:59.973 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:50:00.025 SERIAL « 0x01090004001b032001ff34 (11 bytes) 17:50:00.025 SERIAL » [ACK] (0x06) 17:50:00.026 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:50:00.027 CNTRLR [Node 027] treating BasicCC Set as a report 17:50:00.028 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:50:05.056 SERIAL » 0x010e00132207600d000125010025f953 (16 bytes) 17:50:05.057 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 249 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCSet] target value: false 17:50:05.060 SERIAL « [ACK] (0x06) 17:50:05.066 SERIAL « 0x0104011301e8 (6 bytes) 17:50:05.067 SERIAL » [ACK] (0x06) 17:50:05.067 DRIVER « [RES] [SendData] was sent: true 17:50:05.088 SERIAL « 0x01070013f900000311 (9 bytes) 17:50:05.088 SERIAL » [ACK] (0x06) 17:50:05.089 DRIVER « [REQ] [SendData] callback id: 249 transmit status: OK 17:50:05.106 SERIAL » 0x010d00132206600d0001250225fa51 (15 bytes) 17:50:05.106 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 250 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 17:50:05.108 SERIAL « [ACK] (0x06) 17:50:05.115 SERIAL « 0x0104011301e8 (6 bytes) 17:50:05.115 SERIAL » [ACK] (0x06) 17:50:05.116 DRIVER « [RES] [SendData] was sent: true 17:50:05.136 SERIAL « 0x01070013fa00000312 (9 bytes) 17:50:05.137 SERIAL » [ACK] (0x06) 17:50:05.137 DRIVER « [REQ] [SendData] callback id: 250 transmit status: OK 17:50:05.151 SERIAL « 0x010d0004002207600d01002503ff66 (15 bytes) 17:50:05.152 CNTRLR [Node 034] [~] [Binary Switch] currentValue: true => true [Endpoint 1] 17:50:05.153 SERIAL » [ACK] (0x06) 17:50:05.154 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: true 17:50:05.176 SERIAL « 0x010d0004002207600d010025030099 (15 bytes) 17:50:05.176 CNTRLR [Node 034] [~] [Binary Switch] currentValue: true => false [Endpoint 1] 17:50:05.177 SERIAL » [ACK] (0x06) 17:50:05.178 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: false 17:50:05.202 SERIAL « 0x0112000400220c600d0100320221320000000088 (20 bytes) 17:50:05.203 CNTRLR [Node 034] [~] [Meter] value[66049]: 45 => 0 [Endpoint 1] 17:50:05.204 CNTRLR [Node 034] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 1] 17:50:05.204 SERIAL » [ACK] (0x06) 17:50:05.206 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 17:50:31.113 SERIAL « 0x01090004001b03300300d9 (11 bytes) 17:50:31.114 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:50:31.115 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:50:31.116 SERIAL » [ACK] (0x06) 17:50:31.117 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:50:31.167 SERIAL « 0x01090004001b03200100cb (11 bytes) 17:50:31.168 SERIAL » [ACK] (0x06) 17:50:31.169 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:50:31.171 CNTRLR [Node 027] treating BasicCC Set as a report 17:50:31.172 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:50:54.036 SERIAL « 0x010c00040003063105042203c427 (14 bytes) 17:50:54.036 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:50:54.037 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 113.5 => 96.4 [Endpoint 0] 17:50:54.037 SERIAL » [ACK] (0x06) 17:50:54.038 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 96.4 17:50:55.036 SERIAL « 0x010c000400030631050422048064 (14 bytes) 17:50:55.037 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:50:55.037 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 96.4 => 115.2 [Endpoint 0] 17:50:55.038 SERIAL » [ACK] (0x06) 17:50:55.039 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 115.2 17:52:08.044 SERIAL « 0x010c0004000306310504220545a0 (14 bytes) 17:52:08.046 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:52:08.047 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 115.2 => 134.9 [Endpoint 0] 17:52:08.048 SERIAL » [ACK] (0x06) 17:52:08.050 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 134.9 17:52:09.044 SERIAL « 0x010c00040003063105042204698d (14 bytes) 17:52:09.045 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:52:09.046 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 134.9 => 112.9 [Endpoint 0] 17:52:09.047 SERIAL » [ACK] (0x06) 17:52:09.048 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 112.9 17:52:22.324 SERIAL « 0x01080004001502840767 (10 bytes) 17:52:22.325 SERIAL » [ACK] (0x06) 17:52:22.325 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:52:22.326 CNTRLR « [Node 021] received wakeup notification 17:52:22.327 CNTRLR [Node 021] The node is now awake. 17:52:23.328 CNTRLR » [Node 021] Sending node back to sleep... 17:52:23.337 SERIAL » 0x010900131502840825fba0 (11 bytes) 17:52:23.338 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 251 └─[WakeUpCCNoMoreInformation] 17:52:23.340 SERIAL « [ACK] (0x06) 17:52:23.346 SERIAL « 0x0104011301e8 (6 bytes) 17:52:23.347 SERIAL » [ACK] (0x06) 17:52:23.348 DRIVER « [RES] [SendData] was sent: true 17:52:23.409 SERIAL « 0x01070013fb00000717 (9 bytes) 17:52:23.409 SERIAL » [ACK] (0x06) 17:52:23.410 DRIVER « [REQ] [SendData] callback id: 251 transmit status: OK 17:52:23.417 CNTRLR [Node 021] The node is now asleep. 17:53:23.503 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:53:23.505 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:53:23.506 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:53:23.507 SERIAL » [ACK] (0x06) 17:53:23.508 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:53:23.628 SERIAL « 0x010900040020032001ff0f (11 bytes) 17:53:23.628 SERIAL » [ACK] (0x06) 17:53:23.629 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:53:23.630 CNTRLR [Node 032] treating BasicCC Set as a report 17:53:23.630 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:53:23.664 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:53:23.665 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:53:23.666 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:53:23.666 SERIAL » [ACK] (0x06) 17:53:23.667 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:53:23.683 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:53:23.684 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:53:23.685 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:53:23.685 SERIAL » [ACK] (0x06) 17:53:23.686 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:53:23.696 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:53:23.697 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:53:23.698 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:53:23.698 SERIAL » [ACK] (0x06) 17:53:23.703 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:53:23.728 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:53:23.728 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:53:23.730 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:53:23.730 SERIAL » [ACK] (0x06) 17:53:23.731 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:53:23.733 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:53:23.735 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:53:23.736 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:53:23.736 SERIAL » [ACK] (0x06) 17:53:23.737 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:53:23.814 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:53:23.814 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:53:23.815 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:53:23.815 SERIAL » [ACK] (0x06) 17:53:23.816 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:53:23.904 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:53:23.905 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:53:23.905 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:53:23.906 SERIAL » [ACK] (0x06) 17:53:23.907 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:53:23.947 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:53:23.948 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:53:23.948 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:53:23.948 SERIAL » [ACK] (0x06) 17:53:23.949 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:53:23.963 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:53:23.964 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:53:23.965 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:53:23.965 SERIAL » [ACK] (0x06) 17:53:23.966 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:53:24.111 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:53:24.112 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:53:24.112 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:53:24.112 SERIAL » [ACK] (0x06) 17:53:24.113 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:53:29.731 SERIAL « 0x01090004000b0380034b32 (11 bytes) 17:53:29.733 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 17:53:29.734 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 17:53:29.734 SERIAL » [ACK] (0x06) 17:53:29.736 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 17:53:29.790 SERIAL « 0x010c0004000b064303014203e812 (14 bytes) 17:53:29.792 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 0] 17:53:29.794 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 17:53:29.794 SERIAL » [ACK] (0x06) 17:53:29.796 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 17:53:29.847 SERIAL « 0x010a0004000b044608007fcf (12 bytes) 17:53:29.849 CNTRLR [Node 011] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 17:53:29.850 CNTRLR [Node 011] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 17:53:29.850 SERIAL » [ACK] (0x06) 17:53:29.852 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ClimateControlScheduleCCOverrideReport] override type: None override state: Unused 17:53:29.901 SERIAL « 0x01080004000b02840779 (10 bytes) 17:53:29.902 SERIAL » [ACK] (0x06) 17:53:29.904 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:53:29.906 CNTRLR « [Node 011] received wakeup notification 17:53:29.907 CNTRLR [Node 011] The node is now awake. 17:53:29.908 CNTRLR [Node 011] expects some queries after wake up, so it shall receive 17:53:29.909 CNTRLR [Node 011] compat query "Battery"::get() 17:53:29.919 SERIAL » 0x010900130b02800225fcb7 (11 bytes) 17:53:29.920 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 252 └─[BatteryCCGet] 17:53:29.926 SERIAL « [ACK] (0x06) 17:53:29.928 SERIAL « 0x0104011301e8 (6 bytes) 17:53:29.931 SERIAL » [ACK] (0x06) 17:53:29.931 DRIVER « [RES] [SendData] was sent: true 17:53:29.947 SERIAL « 0x01070013fc00000314 (9 bytes) 17:53:29.948 SERIAL » [ACK] (0x06) 17:53:29.948 DRIVER « [REQ] [SendData] callback id: 252 transmit status: OK 17:53:29.957 SERIAL « 0x01090004000b0380034b32 (11 bytes) 17:53:29.958 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 17:53:29.959 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 17:53:29.960 SERIAL » [ACK] (0x06) 17:53:29.961 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 17:53:29.963 CNTRLR [Node 011] API call successful 17:53:29.964 CNTRLR [Node 011] compat query "Thermostat Setpoint"::get(1) 17:53:29.970 SERIAL » 0x010a00130b0343020125fd76 (12 bytes) 17:53:29.970 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 253 └─[ThermostatSetpointCCGet] setpoint type: Heating 17:53:29.972 SERIAL « [ACK] (0x06) 17:53:29.978 SERIAL « 0x0104011301e8 (6 bytes) 17:53:29.979 SERIAL » [ACK] (0x06) 17:53:29.980 DRIVER « [RES] [SendData] was sent: true 17:53:29.996 SERIAL « 0x01070013fd00000315 (9 bytes) 17:53:29.996 SERIAL » [ACK] (0x06) 17:53:29.997 DRIVER « [REQ] [SendData] callback id: 253 transmit status: OK 17:53:30.006 SERIAL « 0x010c0004000b064303014203e812 (14 bytes) 17:53:30.007 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 0] 17:53:30.008 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 17:53:30.008 SERIAL » [ACK] (0x06) 17:53:30.009 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 17:53:30.011 CNTRLR [Node 011] API call successful 17:53:31.011 CNTRLR » [Node 011] Sending node back to sleep... 17:53:31.022 SERIAL » 0x010900130b02840825febb (11 bytes) 17:53:31.022 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 254 └─[WakeUpCCNoMoreInformation] 17:53:31.024 SERIAL « [ACK] (0x06) 17:53:31.031 SERIAL « 0x0104011301e8 (6 bytes) 17:53:31.031 SERIAL » [ACK] (0x06) 17:53:31.032 DRIVER « [RES] [SendData] was sent: true 17:53:31.048 SERIAL « 0x01070013fe00000217 (9 bytes) 17:53:31.048 SERIAL » [ACK] (0x06) 17:53:31.049 DRIVER « [REQ] [SendData] callback id: 254 transmit status: OK 17:53:31.053 CNTRLR [Node 011] The node is now asleep. 17:53:39.348 SERIAL « 0x0108000400080284077a (10 bytes) 17:53:39.348 SERIAL » [ACK] (0x06) 17:53:39.349 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:53:39.350 CNTRLR « [Node 008] received wakeup notification 17:53:39.351 CNTRLR [Node 008] The node is now awake. 17:53:40.352 CNTRLR » [Node 008] Sending node back to sleep... 17:53:40.360 SERIAL » 0x010900130802840825ffb9 (11 bytes) 17:53:40.360 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 255 └─[WakeUpCCNoMoreInformation] 17:53:40.363 SERIAL « [ACK] (0x06) 17:53:40.369 SERIAL « 0x0104011301e8 (6 bytes) 17:53:40.370 SERIAL » [ACK] (0x06) 17:53:40.371 DRIVER « [RES] [SendData] was sent: true 17:53:40.386 SERIAL « 0x01070013ff00000317 (9 bytes) 17:53:40.387 SERIAL » [ACK] (0x06) 17:53:40.387 DRIVER « [REQ] [SendData] callback id: 255 transmit status: OK 17:53:40.392 CNTRLR [Node 008] The node is now asleep. 17:53:54.049 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:53:54.051 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:53:54.052 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:53:54.053 SERIAL » [ACK] (0x06) 17:53:54.054 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:53:54.223 SERIAL « 0x01090004002003200100f0 (11 bytes) 17:53:54.223 SERIAL » [ACK] (0x06) 17:53:54.225 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:53:54.226 CNTRLR [Node 032] treating BasicCC Set as a report 17:53:54.227 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:53:54.281 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:53:54.282 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:53:54.283 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:53:54.283 SERIAL » [ACK] (0x06) 17:53:54.285 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:53:54.332 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:53:54.333 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:53:54.334 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:53:54.335 SERIAL » [ACK] (0x06) 17:53:54.336 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:53:54.360 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:53:54.361 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:53:54.362 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:53:54.363 SERIAL » [ACK] (0x06) 17:53:54.364 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:53:54.420 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:53:54.421 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:53:54.425 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:53:54.426 SERIAL » [ACK] (0x06) 17:53:54.428 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:53:54.468 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:53:54.469 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:53:54.469 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:53:54.470 SERIAL » [ACK] (0x06) 17:53:54.471 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:53:54.518 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:53:54.519 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:53:54.521 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:53:54.522 SERIAL » [ACK] (0x06) 17:53:54.524 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:53:54.535 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:53:54.537 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:53:54.539 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:53:54.540 SERIAL » [ACK] (0x06) 17:53:54.541 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:53:54.576 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:53:54.577 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:53:54.577 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:53:54.578 SERIAL » [ACK] (0x06) 17:53:54.579 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:53:54.790 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:53:54.791 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:53:54.792 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:53:54.793 SERIAL » [ACK] (0x06) 17:53:54.794 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:54:28.057 SERIAL « 0x010c00040003063105042208d23a (14 bytes) 17:54:28.058 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:54:28.059 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 112.9 => 225.8 [Endpoint 0] 17:54:28.059 SERIAL » [ACK] (0x06) 17:54:28.060 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 225.8 17:54:29.058 SERIAL « 0x010c000400030631050422046b8f (14 bytes) 17:54:29.059 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:54:29.060 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 225.8 => 113.1 [Endpoint 0] 17:54:29.061 SERIAL » [ACK] (0x06) 17:54:29.063 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 113.1 17:54:47.346 SERIAL « 0x01080004001b02840769 (10 bytes) 17:54:47.347 SERIAL » [ACK] (0x06) 17:54:47.348 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:54:47.350 CNTRLR « [Node 027] received wakeup notification 17:54:47.351 CNTRLR [Node 027] The node is now awake. 17:54:48.060 SERIAL « 0x010c0004000306310504220839d1 (14 bytes) 17:54:48.061 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:54:48.062 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 113.1 => 210.5 [Endpoint 0] 17:54:48.063 SERIAL » [ACK] (0x06) 17:54:48.065 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 210.5 17:54:48.352 CNTRLR » [Node 027] Sending node back to sleep... 17:54:48.361 SERIAL » 0x010900131b028408250154 (11 bytes) 17:54:48.362 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 1 └─[WakeUpCCNoMoreInformation] 17:54:48.364 SERIAL « [ACK] (0x06) 17:54:48.370 SERIAL « 0x0104011301e8 (6 bytes) 17:54:48.371 SERIAL » [ACK] (0x06) 17:54:48.371 DRIVER « [RES] [SendData] was sent: true 17:54:48.387 SERIAL « 0x0107001301000003e9 (9 bytes) 17:54:48.387 SERIAL » [ACK] (0x06) 17:54:48.388 DRIVER « [REQ] [SendData] callback id: 1 transmit status: OK 17:54:48.396 CNTRLR [Node 027] The node is now asleep. 17:54:49.060 SERIAL « 0x010c000400030631050422034caf (14 bytes) 17:54:49.061 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:54:49.062 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 210.5 => 84.4 [Endpoint 0] 17:54:49.063 SERIAL » [ACK] (0x06) 17:54:49.064 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 84.4 17:54:50.060 SERIAL « 0x010c00040003063105042204a347 (14 bytes) 17:54:50.061 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:54:50.062 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 84.4 => 118.7 [Endpoint 0] 17:54:50.063 SERIAL » [ACK] (0x06) 17:54:50.065 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 118.7 17:54:52.062 SERIAL « 0x010c00040003063105042203d83b (14 bytes) 17:54:52.063 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:54:52.064 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 118.7 => 98.4 [Endpoint 0] 17:54:52.066 SERIAL » [ACK] (0x06) 17:54:52.085 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 98.4 17:54:52.098 SERIAL « 0x01080004001102840763 (10 bytes) 17:54:52.099 SERIAL » [ACK] (0x06) 17:54:52.101 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:54:52.103 CNTRLR « [Node 017] received wakeup notification 17:54:52.104 CNTRLR [Node 017] The node is now awake. 17:54:53.107 CNTRLR » [Node 017] Sending node back to sleep... 17:54:53.115 SERIAL » 0x010900131102840825025d (11 bytes) 17:54:53.116 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 2 └─[WakeUpCCNoMoreInformation] 17:54:53.118 SERIAL « [ACK] (0x06) 17:54:53.124 SERIAL « 0x0104011301e8 (6 bytes) 17:54:53.124 SERIAL » [ACK] (0x06) 17:54:53.125 DRIVER « [RES] [SendData] was sent: true 17:54:53.141 SERIAL « 0x0107001302000002eb (9 bytes) 17:54:53.142 SERIAL » [ACK] (0x06) 17:54:53.143 DRIVER « [REQ] [SendData] callback id: 2 transmit status: OK 17:54:53.147 CNTRLR [Node 017] The node is now asleep. 17:54:55.060 SERIAL « 0x010c000400030631050422047d99 (14 bytes) 17:54:55.061 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:54:55.061 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 98.4 => 114.9 [Endpoint 0] 17:54:55.061 SERIAL » [ACK] (0x06) 17:54:55.062 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 114.9 17:54:56.056 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:54:56.057 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:54:56.058 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:54:56.059 SERIAL » [ACK] (0x06) 17:54:56.060 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:54:56.110 SERIAL « 0x010900040020032001ff0f (11 bytes) 17:54:56.110 SERIAL » [ACK] (0x06) 17:54:56.111 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:54:56.113 CNTRLR [Node 032] treating BasicCC Set as a report 17:54:56.114 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:54:56.120 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:54:56.122 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:54:56.123 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:54:56.124 SERIAL » [ACK] (0x06) 17:54:56.125 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:54:56.135 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:54:56.136 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:54:56.137 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:54:56.138 SERIAL » [ACK] (0x06) 17:54:56.139 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:54:56.184 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:54:56.185 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:54:56.186 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:54:56.187 SERIAL » [ACK] (0x06) 17:54:56.188 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:54:56.196 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:54:56.197 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:54:56.198 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:54:56.199 SERIAL » [ACK] (0x06) 17:54:56.200 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:54:56.258 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:54:56.259 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:54:56.259 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:54:56.260 SERIAL » [ACK] (0x06) 17:54:56.261 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:54:56.275 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:54:56.276 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:54:56.277 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:54:56.277 SERIAL » [ACK] (0x06) 17:54:56.278 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:54:56.336 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:54:56.337 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:54:56.338 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:54:56.338 SERIAL » [ACK] (0x06) 17:54:56.340 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:54:56.522 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:54:56.523 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:54:56.523 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:54:56.524 SERIAL » [ACK] (0x06) 17:54:56.526 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:54:56.564 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:54:56.566 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:54:56.567 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:54:56.567 SERIAL » [ACK] (0x06) 17:54:56.569 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:54:56.676 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:54:56.677 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:54:56.678 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:54:56.679 SERIAL » [ACK] (0x06) 17:54:56.680 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:55:26.736 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:55:26.738 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:55:26.741 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:55:26.742 SERIAL » [ACK] (0x06) 17:55:26.745 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:55:26.792 SERIAL « 0x01090004002003200100f0 (11 bytes) 17:55:26.793 SERIAL » [ACK] (0x06) 17:55:26.795 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:55:26.797 CNTRLR [Node 032] treating BasicCC Set as a report 17:55:26.798 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:55:26.846 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:55:26.847 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:55:26.847 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:55:26.848 SERIAL » [ACK] (0x06) 17:55:26.849 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:55:26.861 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:55:26.862 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:55:26.863 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:55:26.863 SERIAL » [ACK] (0x06) 17:55:26.864 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:55:26.912 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:55:26.912 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:55:26.913 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:55:26.913 SERIAL » [ACK] (0x06) 17:55:26.914 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:55:27.043 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:55:27.044 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:55:27.045 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:55:27.045 SERIAL » [ACK] (0x06) 17:55:27.046 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:55:27.060 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:55:27.061 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:55:27.062 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:55:27.062 SERIAL » [ACK] (0x06) 17:55:27.063 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:55:27.131 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:55:27.132 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:55:27.132 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:55:27.133 SERIAL » [ACK] (0x06) 17:55:27.134 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:55:27.240 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:55:27.241 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:55:27.241 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:55:27.242 SERIAL » [ACK] (0x06) 17:55:27.243 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:55:27.256 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:55:27.257 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:55:27.257 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:55:27.258 SERIAL » [ACK] (0x06) 17:55:27.258 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:55:27.353 SERIAL « 0x010900040020033003ff1d (11 bytes) 17:55:27.354 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:55:27.354 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:55:27.354 SERIAL » [ACK] (0x06) 17:55:27.355 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:55:27.402 SERIAL « 0x010900040020032001ff0f (11 bytes) 17:55:27.403 SERIAL » [ACK] (0x06) 17:55:27.403 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:55:27.404 CNTRLR [Node 032] treating BasicCC Set as a report 17:55:27.405 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:55:39.115 SERIAL « 0x01080004001e0284076c (10 bytes) 17:55:39.117 SERIAL » [ACK] (0x06) 17:55:39.118 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:55:39.120 CNTRLR « [Node 030] received wakeup notification 17:55:39.121 CNTRLR [Node 030] The node is now awake. 17:55:39.880 SERIAL « 0x01090004001b033003ff26 (11 bytes) 17:55:39.882 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:55:39.883 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:55:39.884 SERIAL » [ACK] (0x06) 17:55:39.885 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:55:39.935 SERIAL « 0x01090004001b032001ff34 (11 bytes) 17:55:39.935 SERIAL » [ACK] (0x06) 17:55:39.937 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:55:39.939 CNTRLR [Node 027] treating BasicCC Set as a report 17:55:39.940 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:55:40.122 CNTRLR » [Node 030] Sending node back to sleep... 17:55:40.129 SERIAL » 0x010900131e028408250353 (11 bytes) 17:55:40.130 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 3 └─[WakeUpCCNoMoreInformation] 17:55:40.131 SERIAL « [ACK] (0x06) 17:55:40.138 SERIAL « 0x0104011301e8 (6 bytes) 17:55:40.138 SERIAL » [ACK] (0x06) 17:55:40.139 DRIVER « [RES] [SendData] was sent: true 17:55:40.155 SERIAL « 0x0107001303000003eb (9 bytes) 17:55:40.155 SERIAL » [ACK] (0x06) 17:55:40.156 DRIVER « [REQ] [SendData] callback id: 3 transmit status: OK 17:55:40.159 CNTRLR [Node 030] The node is now asleep. 17:55:46.162 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 17:55:46.164 SERIAL » [ACK] (0x06) 17:55:46.165 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 17:55:46.168 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 17:55:46.462 SERIAL « 0x01090004001e033003ff23 (11 bytes) 17:55:46.463 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:55:46.464 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:55:46.465 SERIAL » [ACK] (0x06) 17:55:46.466 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:55:46.516 SERIAL « 0x01090004001e032001ff31 (11 bytes) 17:55:46.517 SERIAL » [ACK] (0x06) 17:55:46.518 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:55:46.520 CNTRLR [Node 030] treating BasicCC Set as a report 17:55:46.520 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:55:47.627 SERIAL « 0x010900040007033003ff3a (11 bytes) 17:55:47.628 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:55:47.629 CNTRLR [Node 007] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:55:47.630 SERIAL » [ACK] (0x06) 17:55:47.631 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:55:47.870 SERIAL « 0x0110000400070a7105000000ff0708000062 (18 bytes) 17:55:47.871 SERIAL » [ACK] (0x06) 17:55:47.872 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 17:55:47.875 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 17:56:05.247 SERIAL « 0x0114000400180e600d010032022144000001bf00007e (22 bytes) 17:56:05.250 CNTRLR [Node 024] [~] [Meter] value[65537]: 4.47 => 4.47 [Endpoint 1] 17:56:05.251 CNTRLR [Node 024] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 1] 17:56:05.252 SERIAL » [ACK] (0x06) 17:56:05.255 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 4.47 time delta: 0 seconds 17:56:05.321 SERIAL « 0x0114000400180e600d02003202214400006d030000ad (22 bytes) 17:56:05.322 CNTRLR [Node 024] [~] [Meter] value[65537]: 279.07 => 279.07 [Endpoint 2] 17:56:05.323 CNTRLR [Node 024] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 2] 17:56:05.324 SERIAL » [ACK] (0x06) 17:56:05.325 DRIVER « [Node 024] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 279.07 time delta: 0 seconds 17:56:05.937 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:56:05.938 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:05.938 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:56:05.939 SERIAL » [ACK] (0x06) 17:56:05.940 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:56:06.029 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:56:06.029 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:06.030 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:56:06.030 SERIAL » [ACK] (0x06) 17:56:06.031 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:56:06.075 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:56:06.076 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:06.077 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:56:06.077 SERIAL » [ACK] (0x06) 17:56:06.078 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:56:06.127 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:56:06.128 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:06.128 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:56:06.129 SERIAL » [ACK] (0x06) 17:56:06.130 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:56:06.214 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:56:06.215 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:06.215 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:56:06.215 SERIAL » [ACK] (0x06) 17:56:06.216 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:56:06.269 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:56:06.269 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:06.270 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:56:06.270 SERIAL » [ACK] (0x06) 17:56:06.271 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:56:06.324 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:56:06.325 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:06.325 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:56:06.326 SERIAL » [ACK] (0x06) 17:56:06.327 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:56:06.341 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:56:06.341 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:06.342 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:56:06.342 SERIAL » [ACK] (0x06) 17:56:06.343 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:56:06.354 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:56:06.355 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:06.355 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:56:06.356 SERIAL » [ACK] (0x06) 17:56:06.357 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:56:06.694 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:56:06.696 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:06.697 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:56:06.698 SERIAL » [ACK] (0x06) 17:56:06.699 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:56:10.762 SERIAL « 0x01090004001b03300300d9 (11 bytes) 17:56:10.763 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:10.764 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:56:10.764 SERIAL » [ACK] (0x06) 17:56:10.765 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:56:10.817 SERIAL « 0x01090004001b03200100cb (11 bytes) 17:56:10.817 SERIAL » [ACK] (0x06) 17:56:10.818 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:56:10.820 CNTRLR [Node 027] treating BasicCC Set as a report 17:56:10.821 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:56:15.627 SERIAL « 0x01090004000703300300c5 (11 bytes) 17:56:15.628 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:15.628 CNTRLR [Node 007] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:56:15.628 SERIAL » [ACK] (0x06) 17:56:15.629 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:56:15.870 SERIAL « 0x0110000400070a7105000000ff070000006a (18 bytes) 17:56:15.870 SERIAL » [ACK] (0x06) 17:56:15.872 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) 17:56:15.907 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 17:56:16.714 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 17:56:16.715 SERIAL » [ACK] (0x06) 17:56:16.715 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  17:56:16.717 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 17:56:16.937 SERIAL « 0x01090004001e03300300dc (11 bytes) 17:56:16.938 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:16.939 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:56:16.940 SERIAL » [ACK] (0x06) 17:56:16.941 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:56:16.991 SERIAL « 0x01090004001e03200100ce (11 bytes) 17:56:16.992 SERIAL » [ACK] (0x06) 17:56:16.993 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:56:16.995 CNTRLR [Node 030] treating BasicCC Set as a report 17:56:16.996 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:56:18.406 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:56:18.407 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:18.408 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:56:18.409 SERIAL » [ACK] (0x06) 17:56:18.410 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:56:18.454 SERIAL « 0x010900040020032001ff0f (11 bytes) 17:56:18.455 SERIAL » [ACK] (0x06) 17:56:18.456 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:56:18.458 CNTRLR [Node 032] treating BasicCC Set as a report 17:56:18.458 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:56:18.491 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:56:18.492 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:18.493 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:56:18.494 SERIAL » [ACK] (0x06) 17:56:18.495 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:56:18.507 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:56:18.509 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:18.510 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:56:18.512 SERIAL » [ACK] (0x06) 17:56:18.513 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:56:18.521 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:56:18.522 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:18.524 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:56:18.526 SERIAL » [ACK] (0x06) 17:56:18.528 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:56:18.563 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:56:18.564 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:18.565 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:56:18.565 SERIAL » [ACK] (0x06) 17:56:18.566 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:56:18.770 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:56:18.771 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:18.772 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:56:18.773 SERIAL » [ACK] (0x06) 17:56:18.775 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:56:18.832 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:56:18.834 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:18.835 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:56:18.836 SERIAL » [ACK] (0x06) 17:56:18.837 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:56:18.887 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:56:18.889 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:18.889 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:56:18.890 SERIAL » [ACK] (0x06) 17:56:18.894 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:56:18.956 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:56:18.957 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:18.960 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:56:18.960 SERIAL » [ACK] (0x06) 17:56:18.962 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:56:19.037 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:56:19.038 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:19.039 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:56:19.039 SERIAL » [ACK] (0x06) 17:56:19.040 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:56:19.136 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:56:19.137 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:19.138 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:56:19.138 SERIAL » [ACK] (0x06) 17:56:19.139 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:56:20.327 SERIAL « 0x010900040007033003ff3a (11 bytes) 17:56:20.328 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:20.328 CNTRLR [Node 007] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:56:20.329 SERIAL » [ACK] (0x06) 17:56:20.330 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:56:20.570 SERIAL « 0x0110000400070a7105000000ff0708000062 (18 bytes) 17:56:20.571 SERIAL » [ACK] (0x06) 17:56:20.572 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 17:56:20.574 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 17:56:49.071 SERIAL « 0x010c00040003063105042208cd25 (14 bytes) 17:56:49.073 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:56:49.074 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 114.9 => 225.3 [Endpoint 0] 17:56:49.075 SERIAL » [ACK] (0x06) 17:56:49.077 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 225.3 17:56:50.071 SERIAL « 0x010c0004000306310504220743a4 (14 bytes) 17:56:50.076 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:56:50.077 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 225.3 => 185.9 [Endpoint 0] 17:56:50.077 SERIAL » [ACK] (0x06) 17:56:50.079 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 185.9 17:56:51.071 SERIAL « 0x010c00040003063105042205f114 (14 bytes) 17:56:51.072 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:56:51.073 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 185.9 => 152.1 [Endpoint 0] 17:56:51.074 SERIAL » [ACK] (0x06) 17:56:51.076 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 152.1 17:56:56.377 SERIAL « 0x01090004001e033003ff23 (11 bytes) 17:56:56.378 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:56:56.379 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:56:56.380 SERIAL » [ACK] (0x06) 17:56:56.381 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:56:56.431 SERIAL « 0x01090004001e032001ff31 (11 bytes) 17:56:56.432 SERIAL » [ACK] (0x06) 17:56:56.433 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:56:56.435 CNTRLR [Node 030] treating BasicCC Set as a report 17:56:56.436 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:56:57.826 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 17:56:57.826 SERIAL » [ACK] (0x06) 17:56:57.828 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 17:56:57.830 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 17:56:58.072 SERIAL « 0x010c00040003063105042203b556 (14 bytes) 17:56:58.073 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:56:58.074 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 152.1 => 94.9 [Endpoint 0] 17:56:58.075 SERIAL » [ACK] (0x06) 17:56:58.076 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 94.9 17:56:59.072 SERIAL « 0x010c00040003063105042204698d (14 bytes) 17:56:59.073 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:56:59.073 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 94.9 => 112.9 [Endpoint 0] 17:56:59.073 SERIAL » [ACK] (0x06) 17:56:59.074 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 112.9 17:57:00.035 SERIAL « 0x01090004001b033003ff26 (11 bytes) 17:57:00.035 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:00.036 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:57:00.036 SERIAL » [ACK] (0x06) 17:57:00.037 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:57:00.089 SERIAL « 0x01090004001b032001ff34 (11 bytes) 17:57:00.090 SERIAL » [ACK] (0x06) 17:57:00.090 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:57:00.091 CNTRLR [Node 027] treating BasicCC Set as a report 17:57:00.092 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:57:13.440 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:57:13.441 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:13.442 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:57:13.443 SERIAL » [ACK] (0x06) 17:57:13.445 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:57:13.479 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:57:13.480 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:13.481 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:57:13.482 SERIAL » [ACK] (0x06) 17:57:13.484 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:57:13.533 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:57:13.534 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:13.535 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:57:13.536 SERIAL » [ACK] (0x06) 17:57:13.537 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:57:13.626 SERIAL « 0x01090004002003200100f0 (11 bytes) 17:57:13.627 SERIAL » [ACK] (0x06) 17:57:13.629 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:57:13.631 CNTRLR [Node 032] treating BasicCC Set as a report 17:57:13.631 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:57:13.750 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:57:13.752 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:13.753 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:57:13.753 SERIAL » [ACK] (0x06) 17:57:13.755 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:57:13.766 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:57:13.768 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:13.769 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:57:13.770 SERIAL » [ACK] (0x06) 17:57:13.772 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:57:13.797 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:57:13.798 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:13.799 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:57:13.800 SERIAL » [ACK] (0x06) 17:57:13.802 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:57:13.810 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:57:13.812 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:13.813 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:57:13.815 SERIAL » [ACK] (0x06) 17:57:13.817 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:57:13.835 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:57:13.836 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:13.837 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:57:13.838 SERIAL » [ACK] (0x06) 17:57:13.840 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:57:13.895 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:57:13.896 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:13.897 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:57:13.897 SERIAL » [ACK] (0x06) 17:57:13.898 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:57:13.943 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:57:13.944 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:13.945 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:57:13.945 SERIAL » [ACK] (0x06) 17:57:13.946 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:57:13.999 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:57:14.000 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:14.000 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:57:14.001 SERIAL » [ACK] (0x06) 17:57:14.002 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:57:14.127 SERIAL « 0x01090004102003300300f2 (11 bytes) 17:57:14.128 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:14.128 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:57:14.129 SERIAL » [ACK] (0x06) 17:57:14.129 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:57:15.606 SERIAL « 0x01090004000703300300c5 (11 bytes) 17:57:15.606 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:15.607 CNTRLR [Node 007] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:57:15.607 SERIAL » [ACK] (0x06) 17:57:15.608 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:57:15.849 SERIAL « 0x0110000400070a7105000000ff070000006a (18 bytes) 17:57:15.850 SERIAL » [ACK] (0x06) 17:57:15.851 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) 17:57:15.892 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 17:57:26.690 SERIAL « 0x01090004001e03300300dc (11 bytes) 17:57:26.691 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:26.692 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:57:26.693 SERIAL » [ACK] (0x06) 17:57:26.695 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:57:26.744 SERIAL « 0x01090004001e03200100ce (11 bytes) 17:57:26.745 SERIAL » [ACK] (0x06) 17:57:26.746 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:57:26.749 CNTRLR [Node 030] treating BasicCC Set as a report 17:57:26.749 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:57:28.868 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 17:57:28.869 SERIAL » [ACK] (0x06) 17:57:28.870 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  17:57:28.873 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 17:57:39.226 SERIAL « 0x01090004001b03300300d9 (11 bytes) 17:57:39.227 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:39.228 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:57:39.228 SERIAL » [ACK] (0x06) 17:57:39.230 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:57:39.281 SERIAL « 0x01090004001b03200100cb (11 bytes) 17:57:39.282 SERIAL » [ACK] (0x06) 17:57:39.283 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:57:39.285 CNTRLR [Node 027] treating BasicCC Set as a report 17:57:39.286 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:57:47.189 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:57:47.190 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:47.191 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:57:47.192 SERIAL » [ACK] (0x06) 17:57:47.193 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:57:47.236 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:57:47.237 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:47.238 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:57:47.239 SERIAL » [ACK] (0x06) 17:57:47.241 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:57:47.286 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:57:47.287 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:47.288 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:57:47.289 SERIAL » [ACK] (0x06) 17:57:47.290 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:57:47.353 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:57:47.355 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:47.355 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:57:47.356 SERIAL » [ACK] (0x06) 17:57:47.357 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:57:47.440 SERIAL « 0x010900040020032001ff0f (11 bytes) 17:57:47.441 SERIAL » [ACK] (0x06) 17:57:47.442 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:57:47.444 CNTRLR [Node 032] treating BasicCC Set as a report 17:57:47.444 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:57:47.449 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:57:47.450 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:47.451 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:57:47.452 SERIAL » [ACK] (0x06) 17:57:47.454 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:57:47.488 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:57:47.489 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:47.490 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:57:47.491 SERIAL » [ACK] (0x06) 17:57:47.492 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:57:47.611 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:57:47.612 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:47.613 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:57:47.614 SERIAL » [ACK] (0x06) 17:57:47.615 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:57:47.738 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:57:47.740 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:47.743 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:57:47.744 SERIAL » [ACK] (0x06) 17:57:47.746 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:57:47.756 SERIAL « 0x010900041020033003ff0d (11 bytes) 17:57:47.758 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:57:47.759 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:57:47.760 SERIAL » [ACK] (0x06) 17:57:47.762 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:58:06.455 SERIAL « 0x010c00040002063105030a0014da (14 bytes) 17:58:06.455 CNTRLR [Node 002] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 17:58:06.456 CNTRLR [Node 002] [~] [Multilevel Sensor] Illuminance: 20 => 20 [Endpoint 0] 17:58:06.456 SERIAL » [ACK] (0x06) 17:58:06.457 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 20 17:58:07.425 SERIAL « 0x01090004001b033003ff26 (11 bytes) 17:58:07.426 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:58:07.426 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:58:07.426 SERIAL » [ACK] (0x06) 17:58:07.427 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:58:07.480 SERIAL « 0x01090004001b032001ff34 (11 bytes) 17:58:07.480 SERIAL » [ACK] (0x06) 17:58:07.481 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:58:07.483 CNTRLR [Node 027] treating BasicCC Set as a report 17:58:07.483 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:58:13.095 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 17:58:13.096 SERIAL » [ACK] (0x06) 17:58:13.097 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 17:58:13.099 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 17:58:14.370 SERIAL « 0x01090004001e033003ff23 (11 bytes) 17:58:14.371 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:58:14.372 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:58:14.372 SERIAL » [ACK] (0x06) 17:58:14.374 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:58:14.425 SERIAL « 0x01090004001e032001ff31 (11 bytes) 17:58:14.426 SERIAL » [ACK] (0x06) 17:58:14.429 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:58:14.431 CNTRLR [Node 030] treating BasicCC Set as a report 17:58:14.432 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:58:19.344 SERIAL « 0x010900040007033003ff3a (11 bytes) 17:58:19.345 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:58:19.346 CNTRLR [Node 007] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:58:19.346 SERIAL » [ACK] (0x06) 17:58:19.347 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:58:19.588 SERIAL « 0x0110000400070a7105000000ff0708000062 (18 bytes) 17:58:19.588 SERIAL » [ACK] (0x06) 17:58:19.589 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 17:58:19.590 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 17:58:38.534 SERIAL « 0x01090004001b03300300d9 (11 bytes) 17:58:38.535 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:58:38.536 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:58:38.537 SERIAL » [ACK] (0x06) 17:58:38.539 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:58:38.588 SERIAL « 0x01090004001b03200100cb (11 bytes) 17:58:38.589 SERIAL » [ACK] (0x06) 17:58:38.590 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:58:38.592 CNTRLR [Node 027] treating BasicCC Set as a report 17:58:38.593 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:58:45.081 SERIAL « 0x010c000400030631050422085fb7 (14 bytes) 17:58:45.082 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:58:45.083 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 112.9 => 214.3 [Endpoint 0] 17:58:45.084 SERIAL » [ACK] (0x06) 17:58:45.085 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 214.3 17:58:46.081 SERIAL « 0x010c0004000306310504220429cd (14 bytes) 17:58:46.083 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:58:46.084 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 214.3 => 106.5 [Endpoint 0] 17:58:46.085 SERIAL » [ACK] (0x06) 17:58:46.087 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 106.5 17:58:48.584 SERIAL « 0x01090004000703300300c5 (11 bytes) 17:58:48.587 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:58:48.587 CNTRLR [Node 007] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:58:48.588 SERIAL » [ACK] (0x06) 17:58:48.589 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:58:48.833 SERIAL « 0x0110000400070a7105000000ff070000006a (18 bytes) 17:58:48.834 SERIAL » [ACK] (0x06) 17:58:48.835 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) 17:58:48.872 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 17:58:49.903 SERIAL « 0x01090004001b033003ff26 (11 bytes) 17:58:49.904 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:58:49.905 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 17:58:49.906 SERIAL » [ACK] (0x06) 17:58:49.907 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 17:58:49.958 SERIAL « 0x01090004001b032001ff34 (11 bytes) 17:58:49.959 SERIAL » [ACK] (0x06) 17:58:49.960 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 17:58:49.961 CNTRLR [Node 027] treating BasicCC Set as a report 17:58:49.962 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 17:58:59.083 SERIAL « 0x010c000400030631050422088a62 (14 bytes) 17:58:59.085 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:58:59.086 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 106.5 => 218.6 [Endpoint 0] 17:58:59.087 SERIAL » [ACK] (0x06) 17:58:59.089 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 218.6 17:59:00.083 SERIAL « 0x010c00040003063105042204789c (14 bytes) 17:59:00.084 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:59:00.085 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 218.6 => 114.4 [Endpoint 0] 17:59:00.085 SERIAL » [ACK] (0x06) 17:59:00.087 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 114.4 17:59:03.328 SERIAL « 0x01090004001e03300300dc (11 bytes) 17:59:03.330 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 17:59:03.331 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 17:59:03.331 SERIAL » [ACK] (0x06) 17:59:03.334 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 17:59:03.383 SERIAL « 0x01090004001e03200100ce (11 bytes) 17:59:03.384 SERIAL » [ACK] (0x06) 17:59:03.385 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 17:59:03.387 CNTRLR [Node 030] treating BasicCC Set as a report 17:59:03.388 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 17:59:04.159 SERIAL « 0x01080004102002840742 (10 bytes) 17:59:04.160 SERIAL » [ACK] (0x06) 17:59:04.162 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:59:04.164 CNTRLR « [Node 032] received wakeup notification 17:59:04.165 CNTRLR [Node 032] The node is now awake. 17:59:04.176 SERIAL » 0x0109001320028405250467 (11 bytes) 17:59:04.177 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 4 └─[WakeUpCCIntervalGet] 17:59:04.180 SERIAL « [ACK] (0x06) 17:59:04.185 SERIAL « 0x0104011301e8 (6 bytes) 17:59:04.186 SERIAL » [ACK] (0x06) 17:59:04.187 DRIVER « [RES] [SendData] was sent: true 17:59:04.225 SERIAL « 0x0107001304000005ea (9 bytes) 17:59:04.226 SERIAL » [ACK] (0x06) 17:59:04.226 DRIVER « [REQ] [SendData] callback id: 4 transmit status: OK 17:59:04.261 SERIAL « 0x01080004102002840742 (10 bytes) 17:59:04.261 SERIAL » [ACK] (0x06) 17:59:04.263 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:59:04.265 CNTRLR « [Node 032] received wakeup notification 17:59:04.296 SERIAL « 0x010c0004002006840600038401d5 (14 bytes) 17:59:04.298 CNTRLR [Node 032] [~] [Wake Up] wakeUpInterval: 900 => 900 [Endpoint 0] 17:59:04.298 CNTRLR [Node 032] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 17:59:04.299 SERIAL » [ACK] (0x06) 17:59:04.301 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 900 seconds controller node id: 1 17:59:04.304 SERIAL « 0x01080004102002840742 (10 bytes) 17:59:04.304 SERIAL » [ACK] (0x06) 17:59:04.305 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:59:04.307 CNTRLR « [Node 032] received wakeup notification 17:59:04.339 SERIAL « 0x01080004102002840742 (10 bytes) 17:59:04.340 SERIAL » [ACK] (0x06) 17:59:04.341 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:59:04.343 CNTRLR « [Node 032] received wakeup notification 17:59:04.433 SERIAL « 0x01080004102002840742 (10 bytes) 17:59:04.434 SERIAL » [ACK] (0x06) 17:59:04.435 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:59:04.438 CNTRLR « [Node 032] received wakeup notification 17:59:04.550 SERIAL « 0x01080004102002840742 (10 bytes) 17:59:04.551 SERIAL » [ACK] (0x06) 17:59:04.551 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:59:04.553 CNTRLR « [Node 032] received wakeup notification 17:59:04.578 SERIAL « 0x01080004102002840742 (10 bytes) 17:59:04.578 SERIAL » [ACK] (0x06) 17:59:04.579 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:59:04.581 CNTRLR « [Node 032] received wakeup notification 17:59:04.658 SERIAL « 0x01080004102002840742 (10 bytes) 17:59:04.659 SERIAL » [ACK] (0x06) 17:59:04.660 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:59:04.663 CNTRLR « [Node 032] received wakeup notification 17:59:04.675 SERIAL « 0x01080004102002840742 (10 bytes) 17:59:04.676 SERIAL » [ACK] (0x06) 17:59:04.677 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:59:04.680 CNTRLR « [Node 032] received wakeup notification 17:59:04.818 SERIAL « 0x01080004102002840742 (10 bytes) 17:59:04.819 SERIAL » [ACK] (0x06) 17:59:04.820 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:59:04.821 CNTRLR « [Node 032] received wakeup notification 17:59:04.903 SERIAL « 0x01080004102002840742 (10 bytes) 17:59:04.904 SERIAL » [ACK] (0x06) 17:59:04.905 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 17:59:04.911 CNTRLR « [Node 032] received wakeup notification 17:59:05.384 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 17:59:05.385 SERIAL » [ACK] (0x06) 17:59:05.386 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  17:59:05.389 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 17:59:05.913 CNTRLR » [Node 032] Sending node back to sleep... 17:59:05.919 SERIAL » 0x010900132002840825056b (11 bytes) 17:59:05.920 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 5 └─[WakeUpCCNoMoreInformation] 17:59:05.921 SERIAL « [ACK] (0x06) 17:59:05.928 SERIAL « 0x0104011301e8 (6 bytes) 17:59:05.929 SERIAL » [ACK] (0x06) 17:59:05.929 DRIVER « [RES] [SendData] was sent: true 17:59:05.990 SERIAL « 0x0107001305000006e8 (9 bytes) 17:59:05.990 SERIAL » [ACK] (0x06) 17:59:05.991 DRIVER « [REQ] [SendData] callback id: 5 transmit status: OK 17:59:05.995 CNTRLR [Node 032] The node is now asleep. 17:59:16.718 SERIAL « 0x0110000400030a32022144000024250000b6 (18 bytes) 17:59:16.720 CNTRLR [Node 003] [~] [Meter] value[65537]: 92.41 => 92.53 [Endpoint 0] 17:59:16.721 CNTRLR [Node 003] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 17:59:16.722 SERIAL » [ACK] (0x06) 17:59:16.724 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 92.53 time delta: 0 seconds 17:59:29.603 SERIAL « 0x01100004001d0a600d02003105012200b034 (18 bytes) 17:59:29.605 CNTRLR [Node 029] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 17:59:29.607 CNTRLR [Node 029] [~] [Multilevel Sensor] Air temperature: 17.4 => 17.6 [Endpoint 2] 17:59:29.607 SERIAL » [ACK] (0x06) 17:59:29.609 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 17.6 17:59:57.088 SERIAL « 0x010c0004000306310504220532d7 (14 bytes) 17:59:57.089 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 17:59:57.090 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 114.4 => 133 [Endpoint 0] 17:59:57.091 SERIAL » [ACK] (0x06) 17:59:57.093 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 133 18:00:00.088 SERIAL « 0x010c00040003063105042204698d (14 bytes) 18:00:00.089 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:00:00.090 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 133 => 112.9 [Endpoint 0] 18:00:00.090 SERIAL » [ACK] (0x06) 18:00:00.091 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 112.9 18:00:05.041 SERIAL » 0x010900130602984025061a (11 bytes) 18:00:05.042 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 6 └─[SecurityCCNonceGet] 18:00:05.044 SERIAL « [ACK] (0x06) 18:00:05.051 SERIAL « 0x0104011301e8 (6 bytes) 18:00:05.051 SERIAL » [ACK] (0x06) 18:00:05.052 DRIVER « [RES] [SendData] was sent: true 18:00:06.422 SERIAL « 0x010700130600008a67 (9 bytes) 18:00:06.423 SERIAL » [ACK] (0x06) 18:00:06.424 DRIVER « [REQ] [SendData] callback id: 6 transmit status: OK 18:00:06.512 SERIAL « 0x0110000400060a98802171f57e59db70b96f (18 bytes) 18:00:06.513 SERIAL » [ACK] (0x06) 18:00:06.514 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x2171f57e59db70b9 18:00:06.525 SERIAL » 0x01240013061d988176867cb7d63c36c374ac78f068bee4a368a721fcc1b28c106 (38 bytes) 880cf2507d7 18:00:06.527 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 7 └─[SecurityCCCommandEncapsulation] │ nonce id: 33 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCSet] setpoint type: Heating value: 10 °C 18:00:06.531 SERIAL « [ACK] (0x06) 18:00:06.538 SERIAL « 0x0104011301e8 (6 bytes) 18:00:06.539 SERIAL » [ACK] (0x06) 18:00:06.540 DRIVER « [RES] [SendData] was sent: true 18:00:06.652 SERIAL « 0x010700130700000ce0 (9 bytes) 18:00:06.653 SERIAL » [ACK] (0x06) 18:00:06.654 DRIVER « [REQ] [SendData] callback id: 7 transmit status: OK 18:00:06.676 SERIAL » 0x0109001306029840250814 (11 bytes) 18:00:06.676 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 8 └─[SecurityCCNonceGet] 18:00:06.679 SERIAL « [ACK] (0x06) 18:00:06.684 SERIAL « 0x0104011301e8 (6 bytes) 18:00:06.685 SERIAL » [ACK] (0x06) 18:00:06.686 DRIVER « [RES] [SendData] was sent: true 18:00:06.744 SERIAL « 0x0107001308000007e4 (9 bytes) 18:00:06.744 SERIAL » [ACK] (0x06) 18:00:06.745 DRIVER « [REQ] [SendData] callback id: 8 transmit status: OK 18:00:06.832 SERIAL « 0x0110000400060a9880b1a69549a9dd5b2932 (18 bytes) 18:00:06.832 SERIAL » [ACK] (0x06) 18:00:06.833 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xb1a69549a9dd5b29 18:00:06.838 SERIAL » 0x01220013061b988124f66ffdf7d8c36d48ba223ce60fcc85b188a8141b9e596aa (36 bytes) 32509fb 18:00:06.839 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 9 └─[SecurityCCCommandEncapsulation] │ nonce id: 177 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:00:06.842 SERIAL « [ACK] (0x06) 18:00:06.849 SERIAL « 0x0104011301e8 (6 bytes) 18:00:06.850 SERIAL » [ACK] (0x06) 18:00:06.851 DRIVER « [RES] [SendData] was sent: true 18:00:06.972 SERIAL « 0x010700130900000def (9 bytes) 18:00:06.972 SERIAL » [ACK] (0x06) 18:00:06.973 DRIVER « [REQ] [SendData] callback id: 9 transmit status: OK 18:00:07.058 SERIAL « 0x0108000400060298402f (10 bytes) 18:00:07.059 SERIAL » [ACK] (0x06) 18:00:07.060 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 18:00:07.079 SERIAL » 0x01110013060a988048b331aeb9ad2918050aa7 (19 bytes) 18:00:07.079 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 10 └─[SecurityCCNonceReport] nonce: 0x48b331aeb9ad2918 18:00:07.083 SERIAL « [ACK] (0x06) 18:00:07.088 SERIAL « 0x0104011301e8 (6 bytes) 18:00:07.089 SERIAL » [ACK] (0x06) 18:00:07.090 DRIVER « [RES] [SendData] was sent: true 18:00:07.195 SERIAL « 0x010700130a00000bea (9 bytes) 18:00:07.196 SERIAL » [ACK] (0x06) 18:00:07.196 DRIVER « [REQ] [SendData] callback id: 10 transmit status: OK 18:00:07.289 SERIAL « 0x011e00040006189881104bc10408638a0273d039cb9148c52763064994412b27 (32 bytes) 18:00:07.290 SERIAL » [ACK] (0x06) 18:00:07.291 DRIVER Dropping message because it could not be deserialized: The command class Appli cation Status is not implemented 18:00:08.578 CNTRLR [Node 006] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 18:00:09.085 SERIAL » 0x0109001306029840250b17 (11 bytes) 18:00:09.085 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 11 └─[SecurityCCNonceGet] 18:00:09.087 SERIAL « [ACK] (0x06) 18:00:09.093 SERIAL « 0x0104011301e8 (6 bytes) 18:00:09.093 SERIAL » [ACK] (0x06) 18:00:09.094 DRIVER « [RES] [SendData] was sent: true 18:00:10.469 SERIAL « 0x010700130b00008a6a (9 bytes) 18:00:10.470 SERIAL » [ACK] (0x06) 18:00:10.471 DRIVER « [REQ] [SendData] callback id: 11 transmit status: OK 18:00:10.558 SERIAL « 0x0110000400060a988071fd106f0ef13d6aa4 (18 bytes) 18:00:10.559 SERIAL » [ACK] (0x06) 18:00:10.560 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x71fd106f0ef13d6a 18:00:10.566 SERIAL » 0x01220013061b988185ff3d4fafc5781b3c6be9f5d9e94aa6711066364f922c768 (36 bytes) 1250947 18:00:10.567 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 9 └─[SecurityCCCommandEncapsulation] │ nonce id: 113 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:00:10.571 SERIAL « [ACK] (0x06) 18:00:10.578 SERIAL « 0x0104011301e8 (6 bytes) 18:00:10.579 SERIAL » [ACK] (0x06) 18:00:10.579 DRIVER « [RES] [SendData] was sent: true 18:00:10.700 SERIAL « 0x010700130900000cee (9 bytes) 18:00:10.701 SERIAL » [ACK] (0x06) 18:00:10.702 DRIVER « [REQ] [SendData] callback id: 9 transmit status: OK 18:00:10.805 SERIAL « 0x0108000400060298402f (10 bytes) 18:00:10.806 SERIAL » [ACK] (0x06) 18:00:10.807 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 18:00:10.817 SERIAL » 0x01110013060a9880b0a27974a22083ba050c44 (19 bytes) 18:00:10.818 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 12 └─[SecurityCCNonceReport] nonce: 0xb0a27974a22083ba 18:00:10.821 SERIAL « [ACK] (0x06) 18:00:10.826 SERIAL « 0x0104011301e8 (6 bytes) 18:00:10.832 SERIAL » [ACK] (0x06) 18:00:10.833 DRIVER « [RES] [SendData] was sent: true 18:00:10.946 SERIAL « 0x010700130c00000ceb (9 bytes) 18:00:10.946 SERIAL » [ACK] (0x06) 18:00:10.947 DRIVER « [REQ] [SendData] callback id: 12 transmit status: OK 18:00:11.039 SERIAL « 0x0124000400061e988136aa27cb68a5d1d2113e250ff65945bbc17556b08d78ca2 (38 bytes) 6490fa60699 18:00:11.040 SERIAL » [ACK] (0x06) 18:00:11.044 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpoint[1]: 25 => 10 [Endpoint 1] 18:00:11.045 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 18:00:11.046 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 18:00:26.467 SERIAL « 0x01090004001e033003ff23 (11 bytes) 18:00:26.469 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:00:26.470 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:00:26.471 SERIAL » [ACK] (0x06) 18:00:26.472 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:00:26.522 SERIAL « 0x01090004001e032001ff31 (11 bytes) 18:00:26.523 SERIAL » [ACK] (0x06) 18:00:26.524 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:00:26.526 CNTRLR [Node 030] treating BasicCC Set as a report 18:00:26.527 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:00:28.222 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 18:00:28.223 SERIAL » [ACK] (0x06) 18:00:28.223 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 18:00:28.225 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 18:00:49.161 SERIAL « 0x01090004001b03300300d9 (11 bytes) 18:00:49.162 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:00:49.163 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:00:49.164 SERIAL » [ACK] (0x06) 18:00:49.168 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:00:49.216 SERIAL « 0x01090004001b03200100cb (11 bytes) 18:00:49.217 SERIAL » [ACK] (0x06) 18:00:49.218 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:00:49.220 CNTRLR [Node 027] treating BasicCC Set as a report 18:00:49.220 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:00:56.920 SERIAL « 0x01090004001e03300300dc (11 bytes) 18:00:56.921 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:00:56.922 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:00:56.922 SERIAL » [ACK] (0x06) 18:00:56.924 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:00:56.975 SERIAL « 0x01090004001e03200100ce (11 bytes) 18:00:56.976 SERIAL » [ACK] (0x06) 18:00:56.977 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:00:56.979 CNTRLR [Node 030] treating BasicCC Set as a report 18:00:56.980 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:00:57.520 SERIAL « 0x01090004001b033003ff26 (11 bytes) 18:00:57.522 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:00:57.523 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:00:57.524 SERIAL » [ACK] (0x06) 18:00:57.528 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:00:57.574 SERIAL « 0x01090004001b032001ff34 (11 bytes) 18:00:57.575 SERIAL » [ACK] (0x06) 18:00:57.577 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:00:57.580 CNTRLR [Node 027] treating BasicCC Set as a report 18:00:57.580 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:01:08.394 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 18:01:08.395 SERIAL » [ACK] (0x06) 18:01:08.396 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  18:01:08.398 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 18:01:17.892 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 18:01:17.893 SERIAL » [ACK] (0x06) 18:01:17.894 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 18:01:17.899 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 18:01:24.579 SERIAL « 0x01090004001e033003ff23 (11 bytes) 18:01:24.580 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:01:24.581 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:01:24.582 SERIAL » [ACK] (0x06) 18:01:24.584 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:01:24.633 SERIAL « 0x01090004001e032001ff31 (11 bytes) 18:01:24.634 SERIAL » [ACK] (0x06) 18:01:24.635 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:01:24.636 CNTRLR [Node 030] treating BasicCC Set as a report 18:01:24.637 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:01:44.408 SERIAL « 0x0110000400120a600d02003105012200a328 (18 bytes) 18:01:44.409 CNTRLR [Node 018] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 18:01:44.410 CNTRLR [Node 018] [~] [Multilevel Sensor] Air temperature: 16.5 => 16.3 [Endpoint 2] 18:01:44.410 SERIAL » [ACK] (0x06) 18:01:44.411 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 16.3 18:01:49.051 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 18:01:49.052 SERIAL » [ACK] (0x06) 18:01:49.054 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  18:01:49.056 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 18:01:54.705 SERIAL « 0x01090004001e03300300dc (11 bytes) 18:01:54.707 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:01:54.708 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:01:54.709 SERIAL » [ACK] (0x06) 18:01:54.710 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:01:54.760 SERIAL « 0x01090004001e03200100ce (11 bytes) 18:01:54.761 SERIAL » [ACK] (0x06) 18:01:54.762 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:01:54.764 CNTRLR [Node 030] treating BasicCC Set as a report 18:01:54.765 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:06.535 SERIAL « 0x01090004001b03300300d9 (11 bytes) 18:02:06.536 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:02:06.541 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:02:06.542 SERIAL » [ACK] (0x06) 18:02:06.543 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:02:06.589 SERIAL « 0x01090004001b03200100cb (11 bytes) 18:02:06.590 SERIAL » [ACK] (0x06) 18:02:06.591 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:02:06.594 CNTRLR [Node 027] treating BasicCC Set as a report 18:02:06.594 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:08.100 SERIAL « 0x010c00040003063105042207b95e (14 bytes) 18:02:08.102 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:02:08.103 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 112.9 => 197.7 [Endpoint 0] 18:02:08.104 SERIAL » [ACK] (0x06) 18:02:08.106 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 197.7 18:02:09.100 SERIAL « 0x010c000400030631050422042ace (14 bytes) 18:02:09.101 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:02:09.103 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 197.7 => 106.6 [Endpoint 0] 18:02:09.103 SERIAL » [ACK] (0x06) 18:02:09.105 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 106.6 18:02:12.743 SERIAL « 0x01090004001b033003ff26 (11 bytes) 18:02:12.744 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:02:12.744 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:02:12.745 SERIAL » [ACK] (0x06) 18:02:12.746 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:02:12.798 SERIAL « 0x01090004001b032001ff34 (11 bytes) 18:02:12.798 SERIAL » [ACK] (0x06) 18:02:12.799 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:02:12.800 CNTRLR [Node 027] treating BasicCC Set as a report 18:02:12.800 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:02:17.691 SERIAL « 0x01090004001e033003ff23 (11 bytes) 18:02:17.692 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:02:17.693 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:02:17.694 SERIAL » [ACK] (0x06) 18:02:17.696 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:02:17.745 SERIAL « 0x01090004001e032001ff31 (11 bytes) 18:02:17.747 SERIAL » [ACK] (0x06) 18:02:17.748 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:02:17.752 CNTRLR [Node 030] treating BasicCC Set as a report 18:02:17.753 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:02:18.615 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 18:02:18.615 SERIAL » [ACK] (0x06) 18:02:18.616 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 18:02:18.618 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 18:02:24.463 SERIAL « 0x010900040008033003ff35 (11 bytes) 18:02:24.464 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:02:24.466 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:02:24.466 SERIAL » [ACK] (0x06) 18:02:24.468 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:02:24.517 SERIAL « 0x010900040008032001ff27 (11 bytes) 18:02:24.518 SERIAL » [ACK] (0x06) 18:02:24.519 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:02:24.522 CNTRLR [Node 008] treating BasicCC Set as a report 18:02:24.522 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:02:34.102 SERIAL « 0x010c00040003063105042208779f (14 bytes) 18:02:34.104 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:02:34.105 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 106.6 => 216.7 [Endpoint 0] 18:02:34.106 SERIAL » [ACK] (0x06) 18:02:34.108 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 216.7 18:02:35.102 SERIAL « 0x010c0004000306310504220707e0 (14 bytes) 18:02:35.104 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:02:35.105 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 216.7 => 179.9 [Endpoint 0] 18:02:35.106 SERIAL » [ACK] (0x06) 18:02:35.108 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 179.9 18:02:37.103 SERIAL « 0x010c00040003063105042208b159 (14 bytes) 18:02:37.105 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:02:37.106 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 179.9 => 222.5 [Endpoint 0] 18:02:37.107 SERIAL » [ACK] (0x06) 18:02:37.109 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 222.5 18:02:38.103 SERIAL « 0x010c00040003063105042203f211 (14 bytes) 18:02:38.104 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:02:38.105 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 222.5 => 101 [Endpoint 0] 18:02:38.106 SERIAL » [ACK] (0x06) 18:02:38.107 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 101 18:02:39.103 SERIAL « 0x010c000400030631050422048f6b (14 bytes) 18:02:39.104 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:02:39.106 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 101 => 116.7 [Endpoint 0] 18:02:39.106 SERIAL » [ACK] (0x06) 18:02:39.112 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 116.7 18:02:52.202 SERIAL « 0x010900040007033003ff3a (11 bytes) 18:02:52.203 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:02:52.204 CNTRLR [Node 007] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:02:52.205 SERIAL » [ACK] (0x06) 18:02:52.206 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:02:52.445 SERIAL « 0x0110000400070a7105000000ff0708000062 (18 bytes) 18:02:52.446 SERIAL » [ACK] (0x06) 18:02:52.448 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 18:02:52.450 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 18:02:54.756 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:02:54.757 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:02:54.758 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:02:54.758 SERIAL » [ACK] (0x06) 18:02:54.760 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:02:54.793 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:02:54.795 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:02:54.796 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:54.796 SERIAL » [ACK] (0x06) 18:02:54.798 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:02:54.858 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:02:54.859 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:02:54.860 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:54.861 SERIAL » [ACK] (0x06) 18:02:54.862 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:02:54.958 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:02:54.959 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:02:54.960 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:54.961 SERIAL » [ACK] (0x06) 18:02:54.963 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:02:54.991 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:02:54.992 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:02:54.994 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:54.996 SERIAL » [ACK] (0x06) 18:02:54.998 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:02:55.033 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:02:55.034 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:02:55.035 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:55.036 SERIAL » [ACK] (0x06) 18:02:55.037 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:02:55.140 SERIAL « 0x01090004002003200100f0 (11 bytes) 18:02:55.140 SERIAL » [ACK] (0x06) 18:02:55.141 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:02:55.142 CNTRLR [Node 032] treating BasicCC Set as a report 18:02:55.142 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:55.442 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:02:55.442 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:02:55.443 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:55.443 SERIAL » [ACK] (0x06) 18:02:55.444 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:02:55.554 SERIAL « 0x01090004102003200100e0 (11 bytes) 18:02:55.555 SERIAL » [ACK] (0x06) 18:02:55.555 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:02:55.556 CNTRLR [Node 032] treating BasicCC Set as a report 18:02:55.556 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:55.594 SERIAL « 0x01090004102003200100e0 (11 bytes) 18:02:55.595 SERIAL » [ACK] (0x06) 18:02:55.595 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:02:55.596 CNTRLR [Node 032] treating BasicCC Set as a report 18:02:55.597 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:55.679 SERIAL « 0x01090004102003200100e0 (11 bytes) 18:02:55.680 SERIAL » [ACK] (0x06) 18:02:55.680 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:02:55.681 CNTRLR [Node 032] treating BasicCC Set as a report 18:02:55.682 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:55.788 SERIAL « 0x01090004102003200100e0 (11 bytes) 18:02:55.789 SERIAL » [ACK] (0x06) 18:02:55.790 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:02:55.792 CNTRLR [Node 032] treating BasicCC Set as a report 18:02:55.793 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:55.851 SERIAL « 0x01090004102003200100e0 (11 bytes) 18:02:55.851 SERIAL » [ACK] (0x06) 18:02:55.853 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:02:55.855 CNTRLR [Node 032] treating BasicCC Set as a report 18:02:55.856 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:55.902 SERIAL « 0x01090004102003200100e0 (11 bytes) 18:02:55.903 SERIAL » [ACK] (0x06) 18:02:55.904 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:02:55.912 CNTRLR [Node 032] treating BasicCC Set as a report 18:02:55.912 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:55.976 SERIAL « 0x01090004102003200100e0 (11 bytes) 18:02:55.977 SERIAL » [ACK] (0x06) 18:02:55.978 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:02:55.980 CNTRLR [Node 032] treating BasicCC Set as a report 18:02:55.980 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:56.035 SERIAL « 0x01090004102003200100e0 (11 bytes) 18:02:56.037 SERIAL » [ACK] (0x06) 18:02:56.038 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:02:56.040 CNTRLR [Node 032] treating BasicCC Set as a report 18:02:56.041 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:56.098 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:02:56.099 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:02:56.100 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:56.100 SERIAL » [ACK] (0x06) 18:02:56.101 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:02:56.113 SERIAL « 0x01090004102003200100e0 (11 bytes) 18:02:56.114 SERIAL » [ACK] (0x06) 18:02:56.115 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:02:56.117 CNTRLR [Node 032] treating BasicCC Set as a report 18:02:56.118 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:56.213 SERIAL « 0x01090004102003200100e0 (11 bytes) 18:02:56.213 SERIAL » [ACK] (0x06) 18:02:56.214 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:02:56.216 CNTRLR [Node 032] treating BasicCC Set as a report 18:02:56.217 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:56.276 SERIAL « 0x01090004102003200100e0 (11 bytes) 18:02:56.276 SERIAL » [ACK] (0x06) 18:02:56.278 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:02:56.280 CNTRLR [Node 032] treating BasicCC Set as a report 18:02:56.281 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:56.345 SERIAL « 0x01090004102003200100e0 (11 bytes) 18:02:56.345 SERIAL » [ACK] (0x06) 18:02:56.346 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:02:56.348 CNTRLR [Node 032] treating BasicCC Set as a report 18:02:56.349 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:56.469 SERIAL « 0x01090004102003200100e0 (11 bytes) 18:02:56.469 SERIAL » [ACK] (0x06) 18:02:56.469 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:02:56.471 CNTRLR [Node 032] treating BasicCC Set as a report 18:02:56.471 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:56.541 SERIAL « 0x01090004102003200100e0 (11 bytes) 18:02:56.542 SERIAL » [ACK] (0x06) 18:02:56.542 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:02:56.543 CNTRLR [Node 032] treating BasicCC Set as a report 18:02:56.544 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:56.606 SERIAL « 0x01090004102003200100e0 (11 bytes) 18:02:56.606 SERIAL » [ACK] (0x06) 18:02:56.607 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:02:56.608 CNTRLR [Node 032] treating BasicCC Set as a report 18:02:56.608 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:02:56.918 SERIAL « 0x01090004102003200100e0 (11 bytes) 18:02:56.918 SERIAL » [ACK] (0x06) 18:02:56.919 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:02:56.920 CNTRLR [Node 032] treating BasicCC Set as a report 18:02:56.920 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:03:04.269 SERIAL » 0x0109001306029840250d11 (11 bytes) 18:03:04.269 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 13 └─[SecurityCCNonceGet] 18:03:04.271 SERIAL « [ACK] (0x06) 18:03:04.277 SERIAL « 0x0104011301e8 (6 bytes) 18:03:04.278 SERIAL » [ACK] (0x06) 18:03:04.278 DRIVER « [RES] [SendData] was sent: true 18:03:05.684 SERIAL « 0x010700130d00008d6b (9 bytes) 18:03:05.685 SERIAL » [ACK] (0x06) 18:03:05.686 DRIVER « [REQ] [SendData] callback id: 13 transmit status: OK 18:03:05.767 SERIAL « 0x0110000400060a9880e6b548626e22ebfedf (18 bytes) 18:03:05.767 SERIAL » [ACK] (0x06) 18:03:05.768 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xe6b548626e22ebfe 18:03:05.773 SERIAL » 0x01240013061d9881722793dcf067ea5ac992509fa10d91b5ebaae648aac7864a6 (38 bytes) f3f0c250ed2 18:03:05.774 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 14 └─[SecurityCCCommandEncapsulation] │ nonce id: 230 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCSet] setpoint type: Heating value: 25 °C 18:03:05.777 SERIAL « [ACK] (0x06) 18:03:05.784 SERIAL « 0x0104011301e8 (6 bytes) 18:03:05.785 SERIAL » [ACK] (0x06) 18:03:05.785 DRIVER « [RES] [SendData] was sent: true 18:03:05.909 SERIAL « 0x010700130e00000de8 (9 bytes) 18:03:05.910 SERIAL » [ACK] (0x06) 18:03:05.910 DRIVER « [REQ] [SendData] callback id: 14 transmit status: OK 18:03:05.918 SERIAL » 0x0109001306029840250f13 (11 bytes) 18:03:05.918 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 15 └─[SecurityCCNonceGet] 18:03:05.920 SERIAL « [ACK] (0x06) 18:03:05.926 SERIAL « 0x0104011301e8 (6 bytes) 18:03:05.926 SERIAL » [ACK] (0x06) 18:03:05.927 DRIVER « [RES] [SendData] was sent: true 18:03:05.990 SERIAL « 0x010700130f000006e2 (9 bytes) 18:03:05.990 SERIAL » [ACK] (0x06) 18:03:05.991 DRIVER « [REQ] [SendData] callback id: 15 transmit status: OK 18:03:06.077 SERIAL « 0x0110000400060a9880fbc59bf7ae6666f6f5 (18 bytes) 18:03:06.077 SERIAL » [ACK] (0x06) 18:03:06.078 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0xfbc59bf7ae6666f6 18:03:06.084 SERIAL » 0x01220013061b9881f8a1b0424515608ef6b3690735a758adfbb0c0b3af9e614bf (36 bytes) 5251070 18:03:06.085 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[SecurityCCCommandEncapsulation] │ nonce id: 251 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:03:06.088 SERIAL « [ACK] (0x06) 18:03:06.096 SERIAL « 0x0104011301e8 (6 bytes) 18:03:06.096 SERIAL » [ACK] (0x06) 18:03:06.097 DRIVER « [RES] [SendData] was sent: true 18:03:06.220 SERIAL « 0x010700131000000df6 (9 bytes) 18:03:06.221 SERIAL » [ACK] (0x06) 18:03:06.222 DRIVER « [REQ] [SendData] callback id: 16 transmit status: OK 18:03:06.302 SERIAL « 0x0108000400060298402f (10 bytes) 18:03:06.303 SERIAL » [ACK] (0x06) 18:03:06.304 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 18:03:06.315 SERIAL » 0x01110013060a98804ce617f7791855660511e5 (19 bytes) 18:03:06.315 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 17 └─[SecurityCCNonceReport] nonce: 0x4ce617f779185566 18:03:06.318 SERIAL « [ACK] (0x06) 18:03:06.324 SERIAL « 0x0104011301e8 (6 bytes) 18:03:06.329 SERIAL » [ACK] (0x06) 18:03:06.330 DRIVER « [RES] [SendData] was sent: true 18:03:06.444 SERIAL « 0x010700131100000df7 (9 bytes) 18:03:06.445 SERIAL » [ACK] (0x06) 18:03:06.447 DRIVER « [REQ] [SendData] callback id: 17 transmit status: OK 18:03:06.533 SERIAL « 0x011e000400061898810e60f1a55c80cd1580d1efcab74c3d7681a5addff7cf76 (32 bytes) 18:03:06.535 SERIAL » [ACK] (0x06) 18:03:06.536 DRIVER Dropping message because it could not be deserialized: The command class Appli cation Status is not implemented 18:03:07.827 CNTRLR [Node 006] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 18:03:08.334 SERIAL » 0x010900130602984025120e (11 bytes) 18:03:08.335 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 18 └─[SecurityCCNonceGet] 18:03:08.337 SERIAL « [ACK] (0x06) 18:03:08.343 SERIAL « 0x0104011301e8 (6 bytes) 18:03:08.343 SERIAL » [ACK] (0x06) 18:03:08.344 DRIVER « [RES] [SendData] was sent: true 18:03:09.731 SERIAL « 0x010700131200008c75 (9 bytes) 18:03:09.732 SERIAL » [ACK] (0x06) 18:03:09.732 DRIVER « [REQ] [SendData] callback id: 18 transmit status: OK 18:03:09.817 SERIAL « 0x0110000400060a988015381305b778b9ec5e (18 bytes) 18:03:09.817 SERIAL » [ACK] (0x06) 18:03:09.818 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x15381305b778b9ec 18:03:09.823 SERIAL » 0x01220013061b98813b0c959184d0e9865ec6a186c6a9fc4f15c49c79afd49338f (36 bytes) 2251082 18:03:09.824 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[SecurityCCCommandEncapsulation] │ nonce id: 21 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:03:09.827 SERIAL « [ACK] (0x06) 18:03:09.834 SERIAL « 0x0104011301e8 (6 bytes) 18:03:09.835 SERIAL » [ACK] (0x06) 18:03:09.835 DRIVER « [RES] [SendData] was sent: true 18:03:09.958 SERIAL « 0x010700131000000df6 (9 bytes) 18:03:09.959 SERIAL » [ACK] (0x06) 18:03:09.960 DRIVER « [REQ] [SendData] callback id: 16 transmit status: OK 18:03:10.502 SERIAL « 0x01090004000703300300c5 (11 bytes) 18:03:10.503 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:10.504 CNTRLR [Node 007] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:03:10.505 SERIAL » [ACK] (0x06) 18:03:10.507 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:03:10.745 SERIAL « 0x0110000400070a7105000000ff070000006a (18 bytes) 18:03:10.746 SERIAL » [ACK] (0x06) 18:03:10.747 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) 18:03:10.782 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 18:03:11.563 CNTRLR [Node 006] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 18:03:12.076 SERIAL » 0x010900130602984025130f (11 bytes) 18:03:12.077 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 19 └─[SecurityCCNonceGet] 18:03:12.079 SERIAL « [ACK] (0x06) 18:03:12.085 SERIAL « 0x0104011301e8 (6 bytes) 18:03:12.086 SERIAL » [ACK] (0x06) 18:03:12.086 DRIVER « [RES] [SendData] was sent: true 18:03:12.144 SERIAL « 0x0107001313000006fe (9 bytes) 18:03:12.144 SERIAL » [ACK] (0x06) 18:03:12.145 DRIVER « [REQ] [SendData] callback id: 19 transmit status: OK 18:03:12.227 SERIAL « 0x0110000400060a98802d6b6209897accf11c (18 bytes) 18:03:12.227 SERIAL » [ACK] (0x06) 18:03:12.228 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceReport] nonce: 0x2d6b6209897accf1 18:03:12.234 SERIAL » 0x01220013061b988154296b0d38086b56b45a4f9dbc14e51c2db67b7682f12b373 (36 bytes) 9251044 18:03:12.235 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[SecurityCCCommandEncapsulation] │ nonce id: 45 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:03:12.238 SERIAL « [ACK] (0x06) 18:03:12.246 SERIAL « 0x0104011301e8 (6 bytes) 18:03:12.246 SERIAL » [ACK] (0x06) 18:03:12.247 DRIVER « [RES] [SendData] was sent: true 18:03:12.367 SERIAL « 0x010700131000000cf7 (9 bytes) 18:03:12.367 SERIAL » [ACK] (0x06) 18:03:12.368 DRIVER « [REQ] [SendData] callback id: 16 transmit status: OK 18:03:12.473 SERIAL « 0x0108000400060298402f (10 bytes) 18:03:12.474 SERIAL » [ACK] (0x06) 18:03:12.474 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 18:03:12.486 SERIAL » 0x01110013060a988068b8a03ed2ada05f051436 (19 bytes) 18:03:12.486 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 20 └─[SecurityCCNonceReport] nonce: 0x68b8a03ed2ada05f 18:03:12.489 SERIAL « [ACK] (0x06) 18:03:12.495 SERIAL « 0x0104011301e8 (6 bytes) 18:03:12.495 SERIAL » [ACK] (0x06) 18:03:12.496 DRIVER « [RES] [SendData] was sent: true 18:03:12.614 SERIAL « 0x010700131400000cf3 (9 bytes) 18:03:12.614 SERIAL » [ACK] (0x06) 18:03:12.615 DRIVER « [REQ] [SendData] callback id: 20 transmit status: OK 18:03:12.707 SERIAL « 0x0124000400061e9881eb7dbc26bebb69602242817f2f61972dcdae186892e6dd9 (38 bytes) c729fef0a9a 18:03:12.708 SERIAL » [ACK] (0x06) 18:03:12.709 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpoint[1]: 10 => 25 [Endpoint 1] 18:03:12.710 CNTRLR [Node 006] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 18:03:12.710 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 25 °C 18:03:17.476 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 18:03:17.476 SERIAL » [ACK] (0x06) 18:03:17.477 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  18:03:17.478 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 18:03:21.405 SERIAL « 0x01090004001e03300300dc (11 bytes) 18:03:21.406 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:21.406 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:03:21.407 SERIAL » [ACK] (0x06) 18:03:21.407 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:03:21.461 SERIAL « 0x01090004001e03200100ce (11 bytes) 18:03:21.461 SERIAL » [ACK] (0x06) 18:03:21.462 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:03:21.463 CNTRLR [Node 030] treating BasicCC Set as a report 18:03:21.463 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:03:28.121 SERIAL « 0x010900040007033003ff3a (11 bytes) 18:03:28.122 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:28.123 CNTRLR [Node 007] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:03:28.123 SERIAL » [ACK] (0x06) 18:03:28.124 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:03:28.365 SERIAL « 0x0110000400070a7105000000ff0708000062 (18 bytes) 18:03:28.366 SERIAL » [ACK] (0x06) 18:03:28.367 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 18:03:28.370 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 18:03:29.279 SERIAL « 0x0108000400060298402f (10 bytes) 18:03:29.280 SERIAL » [ACK] (0x06) 18:03:29.281 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 18:03:29.292 SERIAL » 0x01110013060a98808732382bb2cb7467051535 (19 bytes) 18:03:29.293 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 21 └─[SecurityCCNonceReport] nonce: 0x8732382bb2cb7467 18:03:29.295 SERIAL « [ACK] (0x06) 18:03:29.301 SERIAL « 0x0104011301e8 (6 bytes) 18:03:29.302 SERIAL » [ACK] (0x06) 18:03:29.303 DRIVER « [RES] [SendData] was sent: true 18:03:30.810 SERIAL « 0x010700131500009866 (9 bytes) 18:03:30.810 SERIAL » [ACK] (0x06) 18:03:30.811 DRIVER « [REQ] [SendData] callback id: 21 transmit status: OK 18:03:30.970 SERIAL « 0x0124000400061e98814ab066dc587f430dd11b885f5ef717442a5998874bcf3cc (38 bytes) 8e9255224b6 18:03:30.971 SERIAL » [ACK] (0x06) 18:03:30.972 CNTRLR [Node 006] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 18:03:30.973 CNTRLR [Node 006] [~] [Multilevel Sensor] Air temperature: 18.6 => 18.9 [Endpoint 2] 18:03:30.974 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.9 18:03:31.130 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 18:03:31.131 SERIAL » [ACK] (0x06) 18:03:31.131 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 18:03:31.133 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 18:03:31.686 SERIAL « 0x01090004001e033003ff23 (11 bytes) 18:03:31.687 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:31.688 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:03:31.689 SERIAL » [ACK] (0x06) 18:03:31.690 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:03:31.740 SERIAL « 0x01090004001e032001ff31 (11 bytes) 18:03:31.741 SERIAL » [ACK] (0x06) 18:03:31.742 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:31.744 CNTRLR [Node 030] treating BasicCC Set as a report 18:03:31.745 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:38.515 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:03:38.517 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:38.518 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:03:38.519 SERIAL » [ACK] (0x06) 18:03:38.521 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:03:38.689 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:03:38.690 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:38.690 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:38.691 SERIAL » [ACK] (0x06) 18:03:38.691 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:03:38.722 SERIAL « 0x010900040020032001ff0f (11 bytes) 18:03:38.723 SERIAL » [ACK] (0x06) 18:03:38.723 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:38.725 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:38.725 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:38.728 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:03:38.730 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:38.730 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:38.733 SERIAL » [ACK] (0x06) 18:03:38.735 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:03:38.780 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:03:38.780 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:38.781 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:38.781 SERIAL » [ACK] (0x06) 18:03:38.782 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:03:38.803 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:03:38.803 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:38.804 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:38.804 SERIAL » [ACK] (0x06) 18:03:38.805 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:03:38.936 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:03:38.937 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:38.938 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:38.938 SERIAL » [ACK] (0x06) 18:03:38.939 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:03:39.008 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:03:39.009 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:39.009 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:39.010 SERIAL » [ACK] (0x06) 18:03:39.011 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:03:39.080 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:03:39.080 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:39.082 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:39.082 SERIAL » [ACK] (0x06) 18:03:39.083 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:03:39.127 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:03:39.128 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:39.129 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:39.129 SERIAL » [ACK] (0x06) 18:03:39.130 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:03:39.154 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:39.155 SERIAL » [ACK] (0x06) 18:03:39.157 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:39.158 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:39.159 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:39.229 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:03:39.230 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:39.231 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:39.231 SERIAL » [ACK] (0x06) 18:03:39.232 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:03:39.298 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:39.298 SERIAL » [ACK] (0x06) 18:03:39.299 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:39.301 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:39.302 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:39.351 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:39.352 SERIAL » [ACK] (0x06) 18:03:39.353 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:39.355 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:39.356 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:39.405 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:03:39.406 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:39.407 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:39.408 SERIAL » [ACK] (0x06) 18:03:39.409 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:03:39.452 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:39.453 SERIAL » [ACK] (0x06) 18:03:39.454 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:39.456 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:39.456 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:39.468 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:39.469 SERIAL » [ACK] (0x06) 18:03:39.470 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:39.472 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:39.472 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:39.550 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:03:39.551 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:39.552 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:39.553 SERIAL » [ACK] (0x06) 18:03:39.554 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:03:39.594 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:03:39.595 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:39.596 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:39.597 SERIAL » [ACK] (0x06) 18:03:39.598 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:03:39.668 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:39.669 SERIAL » [ACK] (0x06) 18:03:39.669 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:39.671 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:39.671 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:39.687 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:03:39.688 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:39.689 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:39.689 SERIAL » [ACK] (0x06) 18:03:39.690 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:03:39.702 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:39.703 SERIAL » [ACK] (0x06) 18:03:39.703 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:39.705 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:39.705 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:39.835 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:39.835 SERIAL » [ACK] (0x06) 18:03:39.836 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:39.838 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:39.839 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:39.850 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:39.851 SERIAL » [ACK] (0x06) 18:03:39.852 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:39.855 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:39.855 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:39.902 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:39.902 SERIAL » [ACK] (0x06) 18:03:39.904 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:39.910 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:39.910 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:39.917 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:03:39.920 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:39.921 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:39.922 SERIAL » [ACK] (0x06) 18:03:39.924 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:03:39.992 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:39.993 SERIAL » [ACK] (0x06) 18:03:39.994 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:39.997 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:39.998 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:40.008 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:40.009 SERIAL » [ACK] (0x06) 18:03:40.010 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:40.012 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:40.013 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:40.021 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:40.022 SERIAL » [ACK] (0x06) 18:03:40.023 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:40.028 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:40.028 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:40.094 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:40.095 SERIAL » [ACK] (0x06) 18:03:40.095 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:40.097 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:40.097 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:40.134 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:40.135 SERIAL » [ACK] (0x06) 18:03:40.135 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:40.136 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:40.137 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:40.204 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:40.205 SERIAL » [ACK] (0x06) 18:03:40.205 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:40.206 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:40.207 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:40.281 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:03:40.282 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:40.283 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:40.283 SERIAL » [ACK] (0x06) 18:03:40.284 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:03:40.373 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:40.373 SERIAL » [ACK] (0x06) 18:03:40.374 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:40.375 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:40.376 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:40.490 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:40.492 SERIAL » [ACK] (0x06) 18:03:40.492 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:40.494 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:40.494 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:40.673 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:40.673 SERIAL » [ACK] (0x06) 18:03:40.674 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:40.675 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:40.675 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:40.831 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:40.831 SERIAL » [ACK] (0x06) 18:03:40.832 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:40.834 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:40.835 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:41.071 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:41.072 SERIAL » [ACK] (0x06) 18:03:41.073 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:41.076 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:41.076 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:41.315 SERIAL « 0x010900041020032001ff1f (11 bytes) 18:03:41.316 SERIAL » [ACK] (0x06) 18:03:41.317 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:41.319 CNTRLR [Node 032] treating BasicCC Set as a report 18:03:41.320 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:41.500 SERIAL « 0x010900040011033003ff2c (11 bytes) 18:03:41.501 CNTRLR [Node 017] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:41.502 CNTRLR [Node 017] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:03:41.503 SERIAL » [ACK] (0x06) 18:03:41.504 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:03:41.519 SERIAL « 0x010900040011032001ff3e (11 bytes) 18:03:41.520 SERIAL » [ACK] (0x06) 18:03:41.521 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:03:41.523 CNTRLR [Node 017] treating BasicCC Set as a report 18:03:41.524 CNTRLR [Node 017] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:03:41.758 SERIAL « 0x01090004000803300300ca (11 bytes) 18:03:41.759 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:41.761 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:03:41.762 SERIAL » [ACK] (0x06) 18:03:41.764 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:03:41.812 SERIAL « 0x01090004000803200100d8 (11 bytes) 18:03:41.814 SERIAL » [ACK] (0x06) 18:03:41.816 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:03:41.819 CNTRLR [Node 008] treating BasicCC Set as a report 18:03:41.819 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:03:45.831 SERIAL » 0x011000131209600d000143010101192516e3 (18 bytes) 18:03:45.834 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 22 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCSet] setpoint type: Heating value: 25 °C 18:03:45.841 SERIAL « [ACK] (0x06) 18:03:45.847 SERIAL « 0x0104011301e8 (6 bytes) 18:03:45.848 SERIAL » [ACK] (0x06) 18:03:45.849 DRIVER « [RES] [SendData] was sent: true 18:03:47.361 SERIAL « 0x010700131600009865 (9 bytes) 18:03:47.361 SERIAL » [ACK] (0x06) 18:03:47.362 DRIVER « [REQ] [SendData] callback id: 22 transmit status: OK 18:03:47.368 SERIAL » 0x010e00131207600d00014302012517e9 (16 bytes) 18:03:47.368 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 23 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:03:47.377 SERIAL « [ACK] (0x06) 18:03:47.378 SERIAL « 0x0104011301e8 (6 bytes) 18:03:47.378 SERIAL » [ACK] (0x06) 18:03:47.379 DRIVER « [RES] [SendData] was sent: true 18:03:47.445 SERIAL « 0x0107001317000007fb (9 bytes) 18:03:47.446 SERIAL » [ACK] (0x06) 18:03:47.446 DRIVER « [REQ] [SendData] callback id: 23 transmit status: OK 18:03:47.522 SERIAL « 0x010a000400120422010102c7 (12 bytes) 18:03:47.523 DRIVER Dropping message because it could not be deserialized: The command class Appli cation Status is not implemented 18:03:47.523 SERIAL » [ACK] (0x06) 18:03:48.501 SERIAL « 0x01090004000703300300c5 (11 bytes) 18:03:48.502 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:03:48.504 CNTRLR [Node 007] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:03:48.505 SERIAL » [ACK] (0x06) 18:03:48.508 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:03:48.744 SERIAL « 0x0110000400070a7105000000ff070000006a (18 bytes) 18:03:48.745 SERIAL » [ACK] (0x06) 18:03:48.748 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) 18:03:48.763 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 18:03:49.048 CNTRLR [Node 018] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 18:03:49.554 SERIAL » 0x010e00131207600d00014302012517e9 (16 bytes) 18:03:49.555 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 23 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:03:49.557 SERIAL « [ACK] (0x06) 18:03:49.564 SERIAL « 0x0104011301e8 (6 bytes) 18:03:49.564 SERIAL » [ACK] (0x06) 18:03:49.565 DRIVER « [RES] [SendData] was sent: true 18:03:49.632 SERIAL « 0x0107001317000008f4 (9 bytes) 18:03:49.632 SERIAL » [ACK] (0x06) 18:03:49.633 DRIVER « [REQ] [SendData] callback id: 23 transmit status: OK 18:03:49.742 SERIAL « 0x0110000400120a600d01004303012200fa06 (18 bytes) 18:03:49.744 CNTRLR [Node 018] [~] [Thermostat Setpoint] setpoint[1]: 16 => 25 [Endpoint 1] 18:03:49.745 CNTRLR [Node 018] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 18:03:49.745 SERIAL » [ACK] (0x06) 18:03:49.746 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 25 °C 18:03:57.110 SERIAL « 0x010c0004000306310504220853bb (14 bytes) 18:03:57.111 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:03:57.111 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 116.7 => 213.1 [Endpoint 0] 18:03:57.112 SERIAL » [ACK] (0x06) 18:03:57.112 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 213.1 18:03:58.110 SERIAL « 0x010c000400030631050422041ffb (14 bytes) 18:03:58.111 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:03:58.112 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 213.1 => 105.5 [Endpoint 0] 18:03:58.112 SERIAL » [ACK] (0x06) 18:03:58.113 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 105.5 18:04:00.140 SERIAL » 0x011000131209600d0001430101010a2518fe (18 bytes) 18:04:00.140 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 24 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCSet] setpoint type: Heating value: 10 °C 18:04:00.142 SERIAL « [ACK] (0x06) 18:04:00.149 SERIAL « 0x0104011301e8 (6 bytes) 18:04:00.149 SERIAL » [ACK] (0x06) 18:04:00.150 DRIVER « [RES] [SendData] was sent: true 18:04:01.702 SERIAL « 0x010700131800009c6f (9 bytes) 18:04:01.702 SERIAL » [ACK] (0x06) 18:04:01.703 DRIVER « [REQ] [SendData] callback id: 24 transmit status: OK 18:04:01.717 SERIAL » 0x010e00131207600d00014302012519e7 (16 bytes) 18:04:01.718 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 25 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:04:01.720 SERIAL « [ACK] (0x06) 18:04:01.727 SERIAL « 0x0104011301e8 (6 bytes) 18:04:01.727 SERIAL » [ACK] (0x06) 18:04:01.728 DRIVER « [RES] [SendData] was sent: true 18:04:01.795 SERIAL « 0x0107001319000007f5 (9 bytes) 18:04:01.795 SERIAL » [ACK] (0x06) 18:04:01.796 DRIVER « [REQ] [SendData] callback id: 25 transmit status: OK 18:04:01.906 SERIAL « 0x0110000400120a600d010043030122006498 (18 bytes) 18:04:01.907 CNTRLR [Node 018] [~] [Thermostat Setpoint] setpoint[1]: 25 => 10 [Endpoint 1] 18:04:01.908 CNTRLR [Node 018] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 18:04:01.909 SERIAL » [ACK] (0x06) 18:04:01.911 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 18:04:02.195 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 18:04:02.196 SERIAL » [ACK] (0x06) 18:04:02.197 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  18:04:02.200 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 18:04:02.255 SERIAL « 0x01090004001e03300300dc (11 bytes) 18:04:02.257 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:04:02.258 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:04:02.258 SERIAL » [ACK] (0x06) 18:04:02.260 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:04:02.310 SERIAL « 0x01090004001e03200100ce (11 bytes) 18:04:02.311 SERIAL » [ACK] (0x06) 18:04:02.312 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:04:02.314 CNTRLR [Node 030] treating BasicCC Set as a report 18:04:02.314 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:04:03.068 SERIAL « 0x01090004001b03300300d9 (11 bytes) 18:04:03.085 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:04:03.087 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:04:03.088 SERIAL » [ACK] (0x06) 18:04:03.089 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:04:03.123 SERIAL « 0x01090004001b03200100cb (11 bytes) 18:04:03.125 SERIAL » [ACK] (0x06) 18:04:03.127 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:04:03.131 CNTRLR [Node 027] treating BasicCC Set as a report 18:04:03.131 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:04:08.761 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 18:04:08.762 SERIAL » [ACK] (0x06) 18:04:08.762 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 18:04:08.763 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 18:04:08.829 SERIAL « 0x010900040015033003ff28 (11 bytes) 18:04:08.829 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:04:08.830 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:04:08.830 SERIAL » [ACK] (0x06) 18:04:08.831 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:04:08.883 SERIAL « 0x010900040015032001ff3a (11 bytes) 18:04:08.884 SERIAL » [ACK] (0x06) 18:04:08.885 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:04:08.887 CNTRLR [Node 021] treating BasicCC Set as a report 18:04:08.887 CNTRLR [Node 021] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:04:13.112 SERIAL « 0x010c00040003063105042204d531 (14 bytes) 18:04:13.112 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:04:13.113 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 105.5 => 123.7 [Endpoint 0] 18:04:13.113 SERIAL » [ACK] (0x06) 18:04:13.114 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 123.7 18:04:16.490 SERIAL » 0x011000131609600d00014301010119251aeb (18 bytes) 18:04:16.491 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 26 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCSet] setpoint type: Heating value: 25 °C 18:04:16.493 SERIAL « [ACK] (0x06) 18:04:16.500 SERIAL « 0x0104011301e8 (6 bytes) 18:04:16.501 SERIAL » [ACK] (0x06) 18:04:16.502 DRIVER « [RES] [SendData] was sent: true 18:04:17.756 SERIAL « 0x010700131a00007e8f (9 bytes) 18:04:17.757 SERIAL » [ACK] (0x06) 18:04:17.758 DRIVER « [REQ] [SendData] callback id: 26 transmit status: OK 18:04:17.768 SERIAL » 0x010e00131607600d0001430201251be1 (16 bytes) 18:04:17.769 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 27 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:04:17.771 SERIAL « [ACK] (0x06) 18:04:17.777 SERIAL « 0x0104011301e8 (6 bytes) 18:04:17.778 SERIAL » [ACK] (0x06) 18:04:17.778 DRIVER « [RES] [SendData] was sent: true 18:04:17.799 SERIAL « 0x010700131b000003f3 (9 bytes) 18:04:17.799 SERIAL » [ACK] (0x06) 18:04:17.800 DRIVER « [REQ] [SendData] callback id: 27 transmit status: OK 18:04:17.818 SERIAL « 0x010a000400160422010102c3 (12 bytes) 18:04:17.819 DRIVER Dropping message because it could not be deserialized: The command class Appli cation Status is not implemented 18:04:17.819 SERIAL » [ACK] (0x06) 18:04:19.404 CNTRLR [Node 022] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 18:04:19.914 SERIAL » 0x010e00131607600d0001430201251be1 (16 bytes) 18:04:19.915 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 27 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:04:19.918 SERIAL « [ACK] (0x06) 18:04:19.927 SERIAL « 0x0104011301e8 (6 bytes) 18:04:19.929 SERIAL » [ACK] (0x06) 18:04:19.930 DRIVER « [RES] [SendData] was sent: true 18:04:21.208 SERIAL « 0x010700131b00008171 (9 bytes) 18:04:21.209 SERIAL » [ACK] (0x06) 18:04:21.209 DRIVER « [REQ] [SendData] callback id: 27 transmit status: OK 18:04:21.241 SERIAL « 0x010c00040003063105042208c820 (14 bytes) 18:04:21.241 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:04:21.242 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 123.7 => 224.8 [Endpoint 0] 18:04:21.242 SERIAL » [ACK] (0x06) 18:04:21.243 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 224.8 18:04:21.329 SERIAL « 0x0110000400160a600d01004303012200fa02 (18 bytes) 18:04:21.330 CNTRLR [Node 022] [~] [Thermostat Setpoint] setpoint[1]: 10 => 25 [Endpoint 1] 18:04:21.330 CNTRLR [Node 022] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 18:04:21.330 SERIAL » [ACK] (0x06) 18:04:21.331 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 25 °C 18:04:22.113 SERIAL « 0x010c0004000306310504220457b3 (14 bytes) 18:04:22.114 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:04:22.115 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 224.8 => 111.1 [Endpoint 0] 18:04:22.116 SERIAL » [ACK] (0x06) 18:04:22.117 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 111.1 18:04:28.033 SERIAL » 0x011000131609600d0001430101010a251cfe (18 bytes) 18:04:28.033 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 28 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCSet] setpoint type: Heating value: 10 °C 18:04:28.036 SERIAL « [ACK] (0x06) 18:04:28.042 SERIAL « 0x0104011301e8 (6 bytes) 18:04:28.043 SERIAL » [ACK] (0x06) 18:04:28.043 DRIVER « [RES] [SendData] was sent: true 18:04:29.328 SERIAL « 0x010700131c00008275 (9 bytes) 18:04:29.329 SERIAL » [ACK] (0x06) 18:04:29.329 DRIVER « [REQ] [SendData] callback id: 28 transmit status: OK 18:04:29.335 SERIAL » 0x010e00131607600d0001430201251de7 (16 bytes) 18:04:29.335 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 29 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:04:29.337 SERIAL « [ACK] (0x06) 18:04:29.343 SERIAL « 0x0104011301e8 (6 bytes) 18:04:29.344 SERIAL » [ACK] (0x06) 18:04:29.344 DRIVER « [RES] [SendData] was sent: true 18:04:29.365 SERIAL « 0x010700131d000003f5 (9 bytes) 18:04:29.366 SERIAL » [ACK] (0x06) 18:04:29.366 DRIVER « [REQ] [SendData] callback id: 29 transmit status: OK 18:04:29.384 SERIAL « 0x010a000400160422010102c3 (12 bytes) 18:04:29.385 DRIVER Dropping message because it could not be deserialized: The command class Appli cation Status is not implemented 18:04:29.385 SERIAL » [ACK] (0x06) 18:04:30.969 CNTRLR [Node 022] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 18:04:31.475 SERIAL » 0x010e00131607600d0001430201251de7 (16 bytes) 18:04:31.476 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 29 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:04:31.479 SERIAL « [ACK] (0x06) 18:04:31.485 SERIAL « 0x0104011301e8 (6 bytes) 18:04:31.486 SERIAL » [ACK] (0x06) 18:04:31.487 DRIVER « [RES] [SendData] was sent: true 18:04:31.507 SERIAL « 0x010700131d000002f4 (9 bytes) 18:04:31.507 SERIAL » [ACK] (0x06) 18:04:31.508 DRIVER « [REQ] [SendData] callback id: 29 transmit status: OK 18:04:31.599 SERIAL « 0x0110000400160a600d01004303012200649c (18 bytes) 18:04:31.600 CNTRLR [Node 022] [~] [Thermostat Setpoint] setpoint[1]: 25 => 10 [Endpoint 1] 18:04:31.601 CNTRLR [Node 022] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 18:04:31.602 SERIAL » [ACK] (0x06) 18:04:31.603 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 18:04:34.685 SERIAL « 0x01090004001103300300d3 (11 bytes) 18:04:34.685 CNTRLR [Node 017] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:04:34.686 CNTRLR [Node 017] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:04:34.686 SERIAL » [ACK] (0x06) 18:04:34.687 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:04:34.739 SERIAL « 0x01090004001103200100c1 (11 bytes) 18:04:34.739 SERIAL » [ACK] (0x06) 18:04:34.740 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:04:34.741 CNTRLR [Node 017] treating BasicCC Set as a report 18:04:34.741 CNTRLR [Node 017] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:04:39.801 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 18:04:39.801 SERIAL » [ACK] (0x06) 18:04:39.802 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  18:04:39.805 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 18:04:40.224 SERIAL » 0x011000131609600d00014301010114251ee2 (18 bytes) 18:04:40.225 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 30 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCSet] setpoint type: Heating value: 20 °C 18:04:40.227 SERIAL « [ACK] (0x06) 18:04:40.233 SERIAL « 0x0104011301e8 (6 bytes) 18:04:40.234 SERIAL » [ACK] (0x06) 18:04:40.234 DRIVER « [RES] [SendData] was sent: true 18:04:41.491 SERIAL « 0x010700131e00007f8a (9 bytes) 18:04:41.492 SERIAL » [ACK] (0x06) 18:04:41.492 DRIVER « [REQ] [SendData] callback id: 30 transmit status: OK 18:04:41.505 SERIAL » 0x010e00131607600d0001430201251fe5 (16 bytes) 18:04:41.506 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 31 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:04:41.508 SERIAL « [ACK] (0x06) 18:04:41.514 SERIAL « 0x0104011301e8 (6 bytes) 18:04:41.515 SERIAL » [ACK] (0x06) 18:04:41.516 DRIVER « [RES] [SendData] was sent: true 18:04:41.536 SERIAL « 0x010700131f000002f6 (9 bytes) 18:04:41.537 SERIAL » [ACK] (0x06) 18:04:41.538 DRIVER « [REQ] [SendData] callback id: 31 transmit status: OK 18:04:41.555 SERIAL « 0x010a000400160422010102c3 (12 bytes) 18:04:41.556 DRIVER Dropping message because it could not be deserialized: The command class Appli cation Status is not implemented 18:04:41.556 SERIAL » [ACK] (0x06) 18:04:43.142 CNTRLR [Node 022] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 18:04:43.651 SERIAL » 0x010e00131607600d0001430201251fe5 (16 bytes) 18:04:43.653 DRIVER » [Node 022] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 31 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:04:43.655 SERIAL « [ACK] (0x06) 18:04:43.661 SERIAL « 0x0104011301e8 (6 bytes) 18:04:43.662 SERIAL » [ACK] (0x06) 18:04:43.663 DRIVER « [RES] [SendData] was sent: true 18:04:43.683 SERIAL « 0x010700131f000003f7 (9 bytes) 18:04:43.684 SERIAL » [ACK] (0x06) 18:04:43.685 DRIVER « [REQ] [SendData] callback id: 31 transmit status: OK 18:04:43.775 SERIAL « 0x0110000400160a600d01004303012200c830 (18 bytes) 18:04:43.776 CNTRLR [Node 022] [~] [Thermostat Setpoint] setpoint[1]: 10 => 20 [Endpoint 1] 18:04:43.777 CNTRLR [Node 022] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 18:04:43.778 SERIAL » [ACK] (0x06) 18:04:43.779 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 20 °C 18:04:45.129 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 18:04:45.130 SERIAL » [ACK] (0x06) 18:04:45.131 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 18:04:45.132 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 18:04:47.729 SERIAL « 0x010900040008033003ff35 (11 bytes) 18:04:47.730 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:04:47.731 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:04:47.731 SERIAL » [ACK] (0x06) 18:04:47.733 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:04:47.783 SERIAL « 0x010900040008032001ff27 (11 bytes) 18:04:47.784 SERIAL » [ACK] (0x06) 18:04:47.785 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:04:47.787 CNTRLR [Node 008] treating BasicCC Set as a report 18:04:47.787 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:04:57.116 SERIAL « 0x010c00040003063105042208b45c (14 bytes) 18:04:57.117 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:04:57.117 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 111.1 => 222.8 [Endpoint 0] 18:04:57.118 SERIAL » [ACK] (0x06) 18:04:57.119 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 222.8 18:04:58.116 SERIAL « 0x010c000400030631050422048064 (14 bytes) 18:04:58.117 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:04:58.117 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 222.8 => 115.2 [Endpoint 0] 18:04:58.118 SERIAL » [ACK] (0x06) 18:04:58.119 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 115.2 18:05:02.902 SERIAL » 0x010a00130e032601002520c9 (12 bytes) 18:05:02.903 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 32 └─[MultilevelSwitchCCSet] target value: 0 18:05:02.905 SERIAL « [ACK] (0x06) 18:05:02.911 SERIAL « 0x0104011301e8 (6 bytes) 18:05:02.912 SERIAL » [ACK] (0x06) 18:05:02.913 DRIVER « [RES] [SendData] was sent: true 18:05:02.929 SERIAL « 0x0107001320000003c8 (9 bytes) 18:05:02.929 SERIAL » [ACK] (0x06) 18:05:02.930 DRIVER « [REQ] [SendData] callback id: 32 transmit status: OK 18:05:02.942 SERIAL » 0x010900130e0226022521c9 (11 bytes) 18:05:02.943 DRIVER » [Node 014] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 33 └─[MultilevelSwitchCCGet] 18:05:02.945 SERIAL « [ACK] (0x06) 18:05:02.951 SERIAL « 0x0104011301e8 (6 bytes) 18:05:02.951 SERIAL » [ACK] (0x06) 18:05:02.953 DRIVER « [RES] [SendData] was sent: true 18:05:02.968 SERIAL « 0x0107001321000002c8 (9 bytes) 18:05:02.969 SERIAL » [ACK] (0x06) 18:05:02.969 DRIVER « [REQ] [SendData] callback id: 33 transmit status: OK 18:05:02.978 SERIAL « 0x01090004000e03260327fd (11 bytes) 18:05:02.979 CNTRLR [Node 014] [~] [Multilevel Switch] currentValue: 39 => 39 [Endpoint 0] 18:05:02.980 SERIAL » [ACK] (0x06) 18:05:02.981 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 39 18:05:02.986 SERIAL » 0x010a00130d032601002522c8 (12 bytes) 18:05:02.986 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 34 └─[MultilevelSwitchCCSet] target value: 0 18:05:02.989 SERIAL « [ACK] (0x06) 18:05:02.995 SERIAL « 0x0104011301e8 (6 bytes) 18:05:02.996 SERIAL » [ACK] (0x06) 18:05:02.997 DRIVER « [RES] [SendData] was sent: true 18:05:03.033 SERIAL « 0x0107001322000004cd (9 bytes) 18:05:03.033 SERIAL » [ACK] (0x06) 18:05:03.034 DRIVER « [REQ] [SendData] callback id: 34 transmit status: OK 18:05:03.043 SERIAL » 0x010900130d0226022523c8 (11 bytes) 18:05:03.043 DRIVER » [Node 013] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 35 └─[MultilevelSwitchCCGet] 18:05:03.045 SERIAL « [ACK] (0x06) 18:05:03.051 SERIAL « 0x0104011301e8 (6 bytes) 18:05:03.051 SERIAL » [ACK] (0x06) 18:05:03.052 DRIVER « [RES] [SendData] was sent: true 18:05:03.089 SERIAL « 0x0107001323000005cd (9 bytes) 18:05:03.089 SERIAL » [ACK] (0x06) 18:05:03.090 DRIVER « [REQ] [SendData] callback id: 35 transmit status: OK 18:05:03.137 SERIAL « 0x01090004000d03260327fe (11 bytes) 18:05:03.138 CNTRLR [Node 013] [~] [Multilevel Switch] currentValue: 39 => 39 [Endpoint 0] 18:05:03.138 SERIAL » [ACK] (0x06) 18:05:03.139 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 39 18:05:04.078 SERIAL « 0x010c0004000e0631050422059a72 (14 bytes) 18:05:04.079 CNTRLR [Node 014] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:05:04.080 CNTRLR [Node 014] [~] [Multilevel Sensor] Power: 0 => 143.4 [Endpoint 0] 18:05:04.080 SERIAL » [ACK] (0x06) 18:05:04.081 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 143.4 18:05:04.178 SERIAL « 0x010c0004000d06310504220629c1 (14 bytes) 18:05:04.180 CNTRLR [Node 013] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:05:04.181 CNTRLR [Node 013] [~] [Multilevel Sensor] Power: 0 => 157.7 [Endpoint 0] 18:05:04.182 SERIAL » [ACK] (0x06) 18:05:04.183 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 157.7 18:05:09.850 SERIAL « 0x01090004001503300300d7 (11 bytes) 18:05:09.851 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:05:09.855 CNTRLR [Node 021] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:05:09.856 SERIAL » [ACK] (0x06) 18:05:09.858 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:05:09.904 SERIAL « 0x01090004001503200100c5 (11 bytes) 18:05:09.905 SERIAL » [ACK] (0x06) 18:05:09.906 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:05:09.908 CNTRLR [Node 021] treating BasicCC Set as a report 18:05:09.908 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:05:10.273 SERIAL « 0x010c0004000d06310504220000ee (14 bytes) 18:05:10.274 CNTRLR [Node 013] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:05:10.275 CNTRLR [Node 013] [~] [Multilevel Sensor] Power: 157.7 => 0 [Endpoint 0] 18:05:10.275 SERIAL » [ACK] (0x06) 18:05:10.276 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 18:05:11.387 SERIAL « 0x01090004000d03260300d9 (11 bytes) 18:05:11.389 CNTRLR [Node 013] [~] [Multilevel Switch] currentValue: 39 => 0 [Endpoint 0] 18:05:11.390 SERIAL » [ACK] (0x06) 18:05:11.391 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 0 18:05:11.431 SERIAL « 0x010c0004000d06310504220000ee (14 bytes) 18:05:11.433 CNTRLR [Node 013] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:05:11.434 CNTRLR [Node 013] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 18:05:11.434 SERIAL » [ACK] (0x06) 18:05:11.436 DRIVER « [Node 013] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 18:05:12.987 SERIAL « 0x01090004001e033003ff23 (11 bytes) 18:05:12.988 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:05:12.989 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:05:12.989 SERIAL » [ACK] (0x06) 18:05:12.990 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:05:13.000 SERIAL » 0x010e00132207600d00012501ff252471 (16 bytes) 18:05:13.000 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 36 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCSet] target value: true 18:05:13.002 SERIAL « [ACK] (0x06) 18:05:13.008 SERIAL « 0x0104011301e8 (6 bytes) 18:05:13.009 SERIAL » [ACK] (0x06) 18:05:13.009 DRIVER « [RES] [SendData] was sent: true 18:05:13.052 SERIAL « 0x010d0004002207600d01002503ff66 (15 bytes) 18:05:13.053 CNTRLR [Node 034] [~] [Binary Switch] currentValue: false => true [Endpoint 1] 18:05:13.054 SERIAL » [ACK] (0x06) 18:05:13.055 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: true 18:05:13.105 SERIAL « 0x010700132400000ac5 (9 bytes) 18:05:13.106 SERIAL » [ACK] (0x06) 18:05:13.106 DRIVER « [REQ] [SendData] callback id: 36 transmit status: OK 18:05:13.112 SERIAL » 0x010d00132206600d0001250225258e (15 bytes) 18:05:13.112 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 37 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 18:05:13.114 SERIAL « [ACK] (0x06) 18:05:13.120 SERIAL « 0x0104011301e8 (6 bytes) 18:05:13.121 SERIAL » [ACK] (0x06) 18:05:13.121 DRIVER « [RES] [SendData] was sent: true 18:05:13.142 SERIAL « 0x0107001325000003cd (9 bytes) 18:05:13.142 SERIAL » [ACK] (0x06) 18:05:13.143 DRIVER « [REQ] [SendData] callback id: 37 transmit status: OK 18:05:13.157 SERIAL « 0x010d0004002207600d01002503ff66 (15 bytes) 18:05:13.157 CNTRLR [Node 034] [~] [Binary Switch] currentValue: true => true [Endpoint 1] 18:05:13.158 SERIAL » [ACK] (0x06) 18:05:13.159 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: true 18:05:13.270 SERIAL « 0x010c0004000e0631050422002cc1 (14 bytes) 18:05:13.271 CNTRLR [Node 014] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:05:13.271 CNTRLR [Node 014] [~] [Multilevel Sensor] Power: 143.4 => 4.4 [Endpoint 0] 18:05:13.272 SERIAL » [ACK] (0x06) 18:05:13.273 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 4.4 18:05:13.419 SERIAL « 0x01090004001e032001ff31 (11 bytes) 18:05:13.420 SERIAL » [ACK] (0x06) 18:05:13.421 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:05:13.422 CNTRLR [Node 030] treating BasicCC Set as a report 18:05:13.422 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:05:14.852 SERIAL « 0x01090004000e03260300da (11 bytes) 18:05:14.853 CNTRLR [Node 014] [~] [Multilevel Switch] currentValue: 39 => 0 [Endpoint 0] 18:05:14.854 SERIAL » [ACK] (0x06) 18:05:14.856 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 0 18:05:14.870 SERIAL « 0x010c0004000e06310504220000ed (14 bytes) 18:05:14.872 CNTRLR [Node 014] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:05:14.872 CNTRLR [Node 014] [~] [Multilevel Sensor] Power: 4.4 => 0 [Endpoint 0] 18:05:14.873 SERIAL » [ACK] (0x06) 18:05:14.875 DRIVER « [Node 014] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 18:05:15.051 SERIAL « 0x010d0004002207600d01002503ff66 (15 bytes) 18:05:15.052 CNTRLR [Node 034] [~] [Binary Switch] currentValue: true => true [Endpoint 1] 18:05:15.052 SERIAL » [ACK] (0x06) 18:05:15.054 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: true 18:05:17.153 SERIAL « 0x0112000400220c600d01003202213201dd000054 (20 bytes) 18:05:17.154 CNTRLR [Node 034] [~] [Meter] value[66049]: 0 => 47.7 [Endpoint 1] 18:05:17.154 CNTRLR [Node 034] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 1] 18:05:17.155 SERIAL » [ACK] (0x06) 18:05:17.156 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 47.7 time delta: 0 seconds 18:05:17.766 SERIAL » 0x011000132309600d000143010101142526ef (18 bytes) 18:05:17.767 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 38 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCSet] setpoint type: Heating value: 20 °C 18:05:17.772 SERIAL « 0x01090004001b033003ff26 (11 bytes) 18:05:17.773 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:05:17.773 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:05:17.774 SERIAL » [ACK] (0x06) 18:05:17.775 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:05:17.776 SERIAL « [CAN] (0x18) 18:05:17.777 CNTRLR No response from controller after 1/3 attempts. Scheduling next try in 100 ms. 18:05:17.827 SERIAL « 0x01090004001b032001ff34 (11 bytes) 18:05:17.827 SERIAL » [ACK] (0x06) 18:05:17.827 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:05:17.828 CNTRLR [Node 027] treating BasicCC Set as a report 18:05:17.829 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:05:17.877 SERIAL » 0x011000132309600d000143010101142526ef (18 bytes) 18:05:17.878 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 38 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCSet] setpoint type: Heating value: 20 °C 18:05:17.880 SERIAL « [ACK] (0x06) 18:05:17.886 SERIAL « 0x0104011301e8 (6 bytes) 18:05:17.887 SERIAL » [ACK] (0x06) 18:05:17.887 DRIVER « [RES] [SendData] was sent: true 18:05:19.266 SERIAL « 0x010700132600008a47 (9 bytes) 18:05:19.266 SERIAL » [ACK] (0x06) 18:05:19.267 DRIVER « [REQ] [SendData] callback id: 38 transmit status: OK 18:05:19.274 SERIAL » 0x010e00132307600d00014302012527e8 (16 bytes) 18:05:19.274 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:05:19.276 SERIAL « [ACK] (0x06) 18:05:19.282 SERIAL « 0x0104011301e8 (6 bytes) 18:05:19.283 SERIAL » [ACK] (0x06) 18:05:19.283 DRIVER « [RES] [SendData] was sent: true 18:05:19.349 SERIAL « 0x0107001327000008c4 (9 bytes) 18:05:19.349 SERIAL » [ACK] (0x06) 18:05:19.349 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 18:05:19.431 SERIAL « 0x010a000400230422010102f6 (12 bytes) 18:05:19.432 DRIVER Dropping message because it could not be deserialized: The command class Appli cation Status is not implemented 18:05:19.432 SERIAL » [ACK] (0x06) 18:05:20.951 CNTRLR [Node 035] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 18:05:21.456 SERIAL » 0x010e00132307600d00014302012527e8 (16 bytes) 18:05:21.456 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:05:21.459 SERIAL « [ACK] (0x06) 18:05:21.465 SERIAL « 0x0104011301e8 (6 bytes) 18:05:21.465 SERIAL » [ACK] (0x06) 18:05:21.466 DRIVER « [RES] [SendData] was sent: true 18:05:21.523 SERIAL « 0x0107001327000006ca (9 bytes) 18:05:21.524 SERIAL » [ACK] (0x06) 18:05:21.524 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 18:05:21.632 SERIAL « 0x0110000400230a600d01004303012200c805 (18 bytes) 18:05:21.635 CNTRLR [Node 035] [~] [Thermostat Setpoint] setpoint[1]: 10 => 20 [Endpoint 1] 18:05:21.637 CNTRLR [Node 035] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 18:05:21.638 SERIAL » [ACK] (0x06) 18:05:21.640 DRIVER « [Node 035] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 20 °C 18:05:27.119 SERIAL « 0x010c00040003063105042208cd25 (14 bytes) 18:05:27.120 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:05:27.120 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 115.2 => 225.3 [Endpoint 0] 18:05:27.121 SERIAL » [ACK] (0x06) 18:05:27.122 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 225.3 18:05:28.119 SERIAL « 0x010c00040003063105042204698d (14 bytes) 18:05:28.121 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:05:28.121 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 225.3 => 112.9 [Endpoint 0] 18:05:28.122 SERIAL » [ACK] (0x06) 18:05:28.124 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 112.9 18:05:30.119 SERIAL « 0x010c00040003063105042207f611 (14 bytes) 18:05:30.120 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:05:30.120 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 112.9 => 203.8 [Endpoint 0] 18:05:30.121 SERIAL » [ACK] (0x06) 18:05:30.122 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 203.8 18:05:35.120 SERIAL « 0x010c000400030631050422067395 (14 bytes) 18:05:35.120 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:05:35.121 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 203.8 => 165.1 [Endpoint 0] 18:05:35.121 SERIAL » [ACK] (0x06) 18:05:35.122 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 165.1 18:05:36.120 SERIAL « 0x010c0004000306310504220350b3 (14 bytes) 18:05:36.121 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:05:36.122 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 165.1 => 84.8 [Endpoint 0] 18:05:36.123 SERIAL » [ACK] (0x06) 18:05:36.125 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 84.8 18:05:37.120 SERIAL « 0x010c0004000306310504220819f1 (14 bytes) 18:05:37.121 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:05:37.122 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 84.8 => 207.3 [Endpoint 0] 18:05:37.122 SERIAL » [ACK] (0x06) 18:05:37.124 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 207.3 18:05:40.120 SERIAL « 0x010c0004000306310504220620c6 (14 bytes) 18:05:40.121 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:05:40.121 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 207.3 => 156.8 [Endpoint 0] 18:05:40.122 SERIAL » [ACK] (0x06) 18:05:40.123 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 156.8 18:05:42.121 SERIAL « 0x010c0004000306310504220422c6 (14 bytes) 18:05:42.122 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:05:42.123 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 156.8 => 105.8 [Endpoint 0] 18:05:42.124 SERIAL » [ACK] (0x06) 18:05:42.126 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 105.8 18:05:43.120 SERIAL « 0x010c00040003063105042208ca22 (14 bytes) 18:05:43.121 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:05:43.122 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 105.8 => 225 [Endpoint 0] 18:05:43.122 SERIAL » [ACK] (0x06) 18:05:43.123 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 225 18:05:43.861 SERIAL « 0x01090004001e03300300dc (11 bytes) 18:05:43.863 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:05:43.864 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:05:43.865 SERIAL » [ACK] (0x06) 18:05:43.867 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:05:43.916 SERIAL « 0x01090004001e03200100ce (11 bytes) 18:05:43.917 SERIAL » [ACK] (0x06) 18:05:43.918 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:05:43.919 CNTRLR [Node 030] treating BasicCC Set as a report 18:05:43.919 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:05:46.895 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 18:05:46.895 SERIAL » [ACK] (0x06) 18:05:46.897 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  18:05:46.899 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 18:05:48.542 SERIAL « 0x01090004001b03300300d9 (11 bytes) 18:05:48.543 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:05:48.545 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:05:48.546 SERIAL » [ACK] (0x06) 18:05:48.549 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:05:48.596 SERIAL « 0x01090004001b03200100cb (11 bytes) 18:05:48.597 SERIAL » [ACK] (0x06) 18:05:48.598 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:05:48.600 CNTRLR [Node 027] treating BasicCC Set as a report 18:05:48.601 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:05:55.697 SERIAL « 0x01090004001b033003ff26 (11 bytes) 18:05:55.698 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:05:55.698 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:05:55.699 SERIAL » [ACK] (0x06) 18:05:55.701 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:05:55.752 SERIAL « 0x01090004001b032001ff34 (11 bytes) 18:05:55.752 SERIAL » [ACK] (0x06) 18:05:55.753 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:05:55.755 CNTRLR [Node 027] treating BasicCC Set as a report 18:05:55.756 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:06:01.481 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 18:06:01.482 SERIAL » [ACK] (0x06) 18:06:01.482 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 18:06:01.484 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 18:06:03.123 SERIAL « 0x010c000400030631050422039b78 (14 bytes) 18:06:03.124 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:06:03.125 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 225 => 92.3 [Endpoint 0] 18:06:03.126 SERIAL » [ACK] (0x06) 18:06:03.128 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 92.3 18:06:04.123 SERIAL « 0x010c00040003063105042204af4b (14 bytes) 18:06:04.124 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:06:04.125 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 92.3 => 119.9 [Endpoint 0] 18:06:04.126 SERIAL » [ACK] (0x06) 18:06:04.128 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 119.9 18:06:05.123 SERIAL « 0x010c000400030631050422078760 (14 bytes) 18:06:05.124 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:06:05.126 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 119.9 => 192.7 [Endpoint 0] 18:06:05.126 SERIAL » [ACK] (0x06) 18:06:05.128 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 192.7 18:06:08.123 SERIAL « 0x010c0004000306310504220646a0 (14 bytes) 18:06:08.124 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:06:08.125 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 192.7 => 160.6 [Endpoint 0] 18:06:08.126 SERIAL » [ACK] (0x06) 18:06:08.128 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 160.6 18:06:09.023 SERIAL « 0x01090004001e033003ff23 (11 bytes) 18:06:09.024 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:06:09.025 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:06:09.026 SERIAL » [ACK] (0x06) 18:06:09.027 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:06:09.077 SERIAL « 0x01090004001e032001ff31 (11 bytes) 18:06:09.078 SERIAL » [ACK] (0x06) 18:06:09.079 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:06:09.081 CNTRLR [Node 030] treating BasicCC Set as a report 18:06:09.081 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:06:09.123 SERIAL « 0x010c0004000306310504220757b0 (14 bytes) 18:06:09.124 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:06:09.125 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 160.6 => 187.9 [Endpoint 0] 18:06:09.126 SERIAL » [ACK] (0x06) 18:06:09.128 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 187.9 18:06:12.992 SERIAL » 0x010e00132207600d0001250100252882 (16 bytes) 18:06:12.993 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 40 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCSet] target value: false 18:06:12.995 SERIAL « [ACK] (0x06) 18:06:13.002 SERIAL « 0x0104011301e8 (6 bytes) 18:06:13.002 SERIAL » [ACK] (0x06) 18:06:13.003 DRIVER « [RES] [SendData] was sent: true 18:06:13.023 SERIAL « 0x0107001328000003c0 (9 bytes) 18:06:13.024 SERIAL » [ACK] (0x06) 18:06:13.025 DRIVER « [REQ] [SendData] callback id: 40 transmit status: OK 18:06:13.039 SERIAL » 0x010d00132206600d00012502252982 (15 bytes) 18:06:13.040 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 41 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 18:06:13.042 SERIAL « [ACK] (0x06) 18:06:13.049 SERIAL « 0x0104011301e8 (6 bytes) 18:06:13.049 SERIAL » [ACK] (0x06) 18:06:13.050 DRIVER « [RES] [SendData] was sent: true 18:06:13.057 SERIAL « 0x010d0004002207600d010025030099 (15 bytes) 18:06:13.058 CNTRLR [Node 034] [~] [Binary Switch] currentValue: true => false [Endpoint 1] 18:06:13.059 SERIAL » [ACK] (0x06) 18:06:13.061 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: false 18:06:13.082 SERIAL « 0x0107001329000004c6 (9 bytes) 18:06:13.082 SERIAL » [ACK] (0x06) 18:06:13.083 DRIVER « [REQ] [SendData] callback id: 41 transmit status: OK 18:06:13.096 SERIAL « 0x010d0004002207600d010025030099 (15 bytes) 18:06:13.097 CNTRLR [Node 034] [~] [Binary Switch] currentValue: false => false [Endpoint 1] 18:06:13.098 SERIAL » [ACK] (0x06) 18:06:13.099 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: false 18:06:13.153 SERIAL « 0x0112000400220c600d0100320221320000000088 (20 bytes) 18:06:13.154 CNTRLR [Node 034] [~] [Meter] value[66049]: 47.7 => 0 [Endpoint 1] 18:06:13.154 CNTRLR [Node 034] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 1] 18:06:13.155 SERIAL » [ACK] (0x06) 18:06:13.156 DRIVER « [Node 034] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 18:06:32.645 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 18:06:32.645 SERIAL » [ACK] (0x06) 18:06:32.646 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  18:06:32.648 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 18:06:34.752 SERIAL « 0x01090004001b03300300d9 (11 bytes) 18:06:34.753 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:06:34.754 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:06:34.755 SERIAL » [ACK] (0x06) 18:06:34.757 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:06:34.807 SERIAL « 0x01090004001b03200100cb (11 bytes) 18:06:34.808 SERIAL » [ACK] (0x06) 18:06:34.809 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:06:34.811 CNTRLR [Node 027] treating BasicCC Set as a report 18:06:34.812 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:06:36.126 SERIAL « 0x010c0004000306310504220607e1 (14 bytes) 18:06:36.127 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:06:36.128 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 187.9 => 154.3 [Endpoint 0] 18:06:36.129 SERIAL » [ACK] (0x06) 18:06:36.131 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 154.3 18:06:37.126 SERIAL « 0x010c000400030631050422033bd8 (14 bytes) 18:06:37.127 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:06:37.128 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 154.3 => 82.7 [Endpoint 0] 18:06:37.130 SERIAL » [ACK] (0x06) 18:06:37.132 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 82.7 18:06:38.126 SERIAL « 0x010c000400030631050422046581 (14 bytes) 18:06:38.127 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:06:38.128 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 82.7 => 112.5 [Endpoint 0] 18:06:38.129 SERIAL » [ACK] (0x06) 18:06:38.131 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 112.5 18:06:39.126 SERIAL « 0x010c000400030631050422056085 (14 bytes) 18:06:39.127 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:06:39.128 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 112.5 => 137.6 [Endpoint 0] 18:06:39.129 SERIAL » [ACK] (0x06) 18:06:39.131 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 137.6 18:06:40.126 SERIAL « 0x010c000400030631050422048165 (14 bytes) 18:06:40.127 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:06:40.127 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 137.6 => 115.3 [Endpoint 0] 18:06:40.128 SERIAL » [ACK] (0x06) 18:06:40.129 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 115.3 18:06:41.126 SERIAL « 0x010c00040003063105042209977e (14 bytes) 18:06:41.127 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:06:41.128 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 115.3 => 245.5 [Endpoint 0] 18:06:41.129 SERIAL » [ACK] (0x06) 18:06:41.131 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 245.5 18:07:02.896 SERIAL » 0x011000131209600d00014301010114252ad2 (18 bytes) 18:07:02.898 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 42 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCSet] setpoint type: Heating value: 20 °C 18:07:02.900 SERIAL « [ACK] (0x06) 18:07:02.907 SERIAL « 0x0104011301e8 (6 bytes) 18:07:02.907 SERIAL » [ACK] (0x06) 18:07:02.908 DRIVER « [RES] [SendData] was sent: true 18:07:04.379 SERIAL « 0x010700132a00009455 (9 bytes) 18:07:04.379 SERIAL » [ACK] (0x06) 18:07:04.381 DRIVER « [REQ] [SendData] callback id: 42 transmit status: OK 18:07:04.393 SERIAL » 0x010e00131207600d0001430201252bd5 (16 bytes) 18:07:04.394 DRIVER » [Node 018] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 43 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:07:04.396 SERIAL « [ACK] (0x06) 18:07:04.402 SERIAL « 0x0104011301e8 (6 bytes) 18:07:04.403 SERIAL » [ACK] (0x06) 18:07:04.404 DRIVER « [RES] [SendData] was sent: true 18:07:04.470 SERIAL « 0x010700132b000008c8 (9 bytes) 18:07:04.471 SERIAL » [ACK] (0x06) 18:07:04.472 DRIVER « [REQ] [SendData] callback id: 43 transmit status: OK 18:07:04.583 SERIAL « 0x0110000400120a600d01004303012200c834 (18 bytes) 18:07:04.584 CNTRLR [Node 018] [~] [Thermostat Setpoint] setpoint[1]: 10 => 20 [Endpoint 1] 18:07:04.585 CNTRLR [Node 018] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 18:07:04.585 SERIAL » [ACK] (0x06) 18:07:04.587 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 20 °C 18:07:05.128 SERIAL « 0x010c00040003063105042205c124 (14 bytes) 18:07:05.129 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:07:05.131 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 245.5 => 147.3 [Endpoint 0] 18:07:05.132 SERIAL » [ACK] (0x06) 18:07:05.133 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 147.3 18:07:05.716 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 18:07:05.717 SERIAL » [ACK] (0x06) 18:07:05.718 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 18:07:05.721 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 18:07:06.078 SERIAL « 0x01090004001b033003ff26 (11 bytes) 18:07:06.078 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:07:06.079 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:07:06.079 SERIAL » [ACK] (0x06) 18:07:06.080 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:07:06.132 SERIAL « 0x01090004001b032001ff34 (11 bytes) 18:07:06.133 SERIAL » [ACK] (0x06) 18:07:06.133 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:07:06.134 CNTRLR [Node 027] treating BasicCC Set as a report 18:07:06.135 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:07:06.213 SERIAL « 0x010c00040003063105042203f516 (14 bytes) 18:07:06.213 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:07:06.214 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 147.3 => 101.3 [Endpoint 0] 18:07:06.214 SERIAL » [ACK] (0x06) 18:07:06.215 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 101.3 18:07:08.129 SERIAL « 0x010c00040003063105042204ea0e (14 bytes) 18:07:08.134 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:07:08.135 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 101.3 => 125.8 [Endpoint 0] 18:07:08.136 SERIAL » [ACK] (0x06) 18:07:08.138 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 125.8 18:07:09.129 SERIAL « 0x010c0004000306310504220421c5 (14 bytes) 18:07:09.130 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:07:09.131 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 125.8 => 105.7 [Endpoint 0] 18:07:09.132 SERIAL » [ACK] (0x06) 18:07:09.134 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 105.7 18:07:14.129 SERIAL « 0x010c00040003063105042208668e (14 bytes) 18:07:14.130 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:07:14.130 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 105.7 => 215 [Endpoint 0] 18:07:14.130 SERIAL » [ACK] (0x06) 18:07:14.131 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 215 18:07:21.823 SERIAL « 0x01080004001502840767 (10 bytes) 18:07:21.824 SERIAL » [ACK] (0x06) 18:07:21.825 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 18:07:21.827 CNTRLR « [Node 021] received wakeup notification 18:07:21.828 CNTRLR [Node 021] The node is now awake. 18:07:22.829 CNTRLR » [Node 021] Sending node back to sleep... 18:07:22.833 SERIAL » 0x0109001315028408252c77 (11 bytes) 18:07:22.834 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 44 └─[WakeUpCCNoMoreInformation] 18:07:22.835 SERIAL « [ACK] (0x06) 18:07:22.841 SERIAL « 0x0104011301e8 (6 bytes) 18:07:22.842 SERIAL » [ACK] (0x06) 18:07:22.842 DRIVER « [RES] [SendData] was sent: true 18:07:22.903 SERIAL « 0x010700132c000007c0 (9 bytes) 18:07:22.904 SERIAL » [ACK] (0x06) 18:07:22.905 DRIVER « [REQ] [SendData] callback id: 44 transmit status: OK 18:07:22.914 CNTRLR [Node 021] The node is now asleep. 18:07:24.498 SERIAL « 0x01090004001e03300300dc (11 bytes) 18:07:24.499 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:07:24.500 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:07:24.501 SERIAL » [ACK] (0x06) 18:07:24.502 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:07:24.553 SERIAL « 0x01090004001e03200100ce (11 bytes) 18:07:24.553 SERIAL » [ACK] (0x06) 18:07:24.555 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:07:24.558 CNTRLR [Node 030] treating BasicCC Set as a report 18:07:24.559 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:07:36.131 SERIAL « 0x010c00040003063105042206997f (14 bytes) 18:07:36.133 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:07:36.134 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 215 => 168.9 [Endpoint 0] 18:07:36.135 SERIAL » [ACK] (0x06) 18:07:36.137 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 168.9 18:07:36.686 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 18:07:36.687 SERIAL » [ACK] (0x06) 18:07:36.688 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  18:07:36.691 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 18:07:51.114 SERIAL « 0x01090004001b03300300d9 (11 bytes) 18:07:51.115 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:07:51.116 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:07:51.117 SERIAL » [ACK] (0x06) 18:07:51.119 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:07:51.168 SERIAL « 0x01090004001b03200100cb (11 bytes) 18:07:51.169 SERIAL » [ACK] (0x06) 18:07:51.173 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:07:51.175 CNTRLR [Node 027] treating BasicCC Set as a report 18:07:51.175 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:07:59.134 SERIAL « 0x010c000400030631050422039f7c (14 bytes) 18:07:59.136 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:07:59.138 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 168.9 => 92.7 [Endpoint 0] 18:07:59.139 SERIAL » [ACK] (0x06) 18:07:59.140 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 92.7 18:08:01.134 SERIAL « 0x010c0004000306310504220907ee (14 bytes) 18:08:01.135 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:08:01.136 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 92.7 => 231.1 [Endpoint 0] 18:08:01.137 SERIAL » [ACK] (0x06) 18:08:01.139 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 231.1 18:08:02.134 SERIAL « 0x010c000400030631050422065eb8 (14 bytes) 18:08:02.135 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:08:02.136 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 231.1 => 163 [Endpoint 0] 18:08:02.137 SERIAL » [ACK] (0x06) 18:08:02.140 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 163 18:08:03.135 SERIAL « 0x010c0004000306310504220443a7 (14 bytes) 18:08:03.136 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:08:03.137 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 163 => 109.1 [Endpoint 0] 18:08:03.138 SERIAL » [ACK] (0x06) 18:08:03.140 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 109.1 18:08:05.465 SERIAL « 0x01090004001b033003ff26 (11 bytes) 18:08:05.466 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:08:05.466 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:08:05.467 SERIAL » [ACK] (0x06) 18:08:05.467 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:08:05.519 SERIAL « 0x01090004001b032001ff34 (11 bytes) 18:08:05.520 SERIAL » [ACK] (0x06) 18:08:05.520 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:08:05.521 CNTRLR [Node 027] treating BasicCC Set as a report 18:08:05.522 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:08:07.287 SERIAL « 0x01090004000b0380034b32 (11 bytes) 18:08:07.288 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 18:08:07.288 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 18:08:07.289 SERIAL » [ACK] (0x06) 18:08:07.290 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 18:08:07.346 SERIAL « 0x010c0004000b064303014203e812 (14 bytes) 18:08:07.347 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 0] 18:08:07.348 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 18:08:07.348 SERIAL » [ACK] (0x06) 18:08:07.349 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 18:08:07.403 SERIAL « 0x010a0004000b044608007fcf (12 bytes) 18:08:07.404 CNTRLR [Node 011] [~] [Climate Control Schedule] overrideType: 0 => 0 [Endpoint 0] 18:08:07.405 CNTRLR [Node 011] [~] [Climate Control Schedule] overrideState: "Unused" [Endpoint 0] => "Unused" 18:08:07.405 SERIAL » [ACK] (0x06) 18:08:07.406 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ClimateControlScheduleCCOverrideReport] override type: None override state: Unused 18:08:07.458 SERIAL « 0x01080004000b02840779 (10 bytes) 18:08:07.458 SERIAL » [ACK] (0x06) 18:08:07.459 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 18:08:07.460 CNTRLR « [Node 011] received wakeup notification 18:08:07.460 CNTRLR [Node 011] The node is now awake. 18:08:07.461 CNTRLR [Node 011] expects some queries after wake up, so it shall receive 18:08:07.461 CNTRLR [Node 011] compat query "Battery"::get() 18:08:07.466 SERIAL » 0x010900130b028002252d66 (11 bytes) 18:08:07.466 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 45 └─[BatteryCCGet] 18:08:07.468 SERIAL « [ACK] (0x06) 18:08:07.474 SERIAL « 0x0104011301e8 (6 bytes) 18:08:07.474 SERIAL » [ACK] (0x06) 18:08:07.475 DRIVER « [RES] [SendData] was sent: true 18:08:07.501 SERIAL « 0x010700132d000003c5 (9 bytes) 18:08:07.502 SERIAL » [ACK] (0x06) 18:08:07.502 DRIVER « [REQ] [SendData] callback id: 45 transmit status: OK 18:08:07.511 SERIAL « 0x01090004000b0380034b32 (11 bytes) 18:08:07.512 CNTRLR [Node 011] [~] [Battery] level: 75 => 75 [Endpoint 0] 18:08:07.513 CNTRLR [Node 011] [~] [Battery] isLow: false => false [Endpoint 0] 18:08:07.514 SERIAL » [ACK] (0x06) 18:08:07.515 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 75 is low: false 18:08:07.517 CNTRLR [Node 011] API call successful 18:08:07.517 CNTRLR [Node 011] compat query "Thermostat Setpoint"::get(1) 18:08:07.520 SERIAL » 0x010a00130b03430201252ea5 (12 bytes) 18:08:07.521 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 46 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:08:07.523 SERIAL « [ACK] (0x06) 18:08:07.529 SERIAL « 0x0104011301e8 (6 bytes) 18:08:07.529 SERIAL » [ACK] (0x06) 18:08:07.529 DRIVER « [RES] [SendData] was sent: true 18:08:07.546 SERIAL « 0x010700132e000002c7 (9 bytes) 18:08:07.546 SERIAL » [ACK] (0x06) 18:08:07.547 DRIVER « [REQ] [SendData] callback id: 46 transmit status: OK 18:08:07.557 SERIAL « 0x010c0004000b064303014203e812 (14 bytes) 18:08:07.557 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpoint[1]: 10 => 10 [Endpoint 0] 18:08:07.558 CNTRLR [Node 011] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 0] [internal] 0 => 0 18:08:07.558 SERIAL » [ACK] (0x06) 18:08:07.559 DRIVER « [Node 011] [REQ] [ApplicationCommand] └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 18:08:07.560 CNTRLR [Node 011] API call successful 18:08:08.561 CNTRLR » [Node 011] Sending node back to sleep... 18:08:08.566 SERIAL » 0x010900130b028408252f6a (11 bytes) 18:08:08.571 DRIVER » [Node 011] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 47 └─[WakeUpCCNoMoreInformation] 18:08:08.573 SERIAL « [ACK] (0x06) 18:08:08.579 SERIAL « 0x0104011301e8 (6 bytes) 18:08:08.580 SERIAL » [ACK] (0x06) 18:08:08.580 DRIVER « [RES] [SendData] was sent: true 18:08:08.596 SERIAL « 0x010700132f000002c6 (9 bytes) 18:08:08.596 SERIAL » [ACK] (0x06) 18:08:08.597 DRIVER « [REQ] [SendData] callback id: 47 transmit status: OK 18:08:08.599 CNTRLR [Node 011] The node is now asleep. 18:08:09.134 SERIAL « 0x010c000400030631050422050eeb (14 bytes) 18:08:09.135 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:08:09.136 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 109.1 => 129.4 [Endpoint 0] 18:08:09.136 SERIAL » [ACK] (0x06) 18:08:09.137 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 129.4 18:08:10.135 SERIAL « 0x010c000400030631050422088961 (14 bytes) 18:08:10.136 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:08:10.137 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 129.4 => 218.5 [Endpoint 0] 18:08:10.138 SERIAL » [ACK] (0x06) 18:08:10.139 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 218.5 18:08:11.135 SERIAL « 0x010c000400030631050422047b9f (14 bytes) 18:08:11.137 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:08:11.138 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 218.5 => 114.7 [Endpoint 0] 18:08:11.138 SERIAL » [ACK] (0x06) 18:08:11.140 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 114.7 18:08:14.409 SERIAL « 0x01090004000803300300ca (11 bytes) 18:08:14.411 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:08:14.412 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:08:14.413 SERIAL » [ACK] (0x06) 18:08:14.414 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:08:14.464 SERIAL « 0x01090004000803200100d8 (11 bytes) 18:08:14.465 SERIAL » [ACK] (0x06) 18:08:14.466 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:08:14.468 CNTRLR [Node 008] treating BasicCC Set as a report 18:08:14.469 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:08:16.135 SERIAL « 0x010c000400030631050422079b7c (14 bytes) 18:08:16.137 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:08:16.138 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 114.7 => 194.7 [Endpoint 0] 18:08:16.139 SERIAL » [ACK] (0x06) 18:08:16.140 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 194.7 18:08:17.135 SERIAL « 0x010c000400030631050422041afe (14 bytes) 18:08:17.136 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:08:17.136 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 194.7 => 105 [Endpoint 0] 18:08:17.137 SERIAL » [ACK] (0x06) 18:08:17.138 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 105 18:08:20.135 SERIAL « 0x010c00040003063105042207de39 (14 bytes) 18:08:20.137 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:08:20.138 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 105 => 201.4 [Endpoint 0] 18:08:20.139 SERIAL » [ACK] (0x06) 18:08:20.141 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 201.4 18:08:38.138 SERIAL « 0x010c000400030631050422099e77 (14 bytes) 18:08:38.139 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:08:38.140 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 201.4 => 246.2 [Endpoint 0] 18:08:38.141 SERIAL » [ACK] (0x06) 18:08:38.143 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 246.2 18:08:39.137 SERIAL « 0x010c000400030631050422046387 (14 bytes) 18:08:39.139 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:08:39.140 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 246.2 => 112.3 [Endpoint 0] 18:08:39.141 SERIAL » [ACK] (0x06) 18:08:39.143 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 112.3 18:08:41.515 SERIAL « 0x0108000400080284077a (10 bytes) 18:08:41.516 SERIAL » [ACK] (0x06) 18:08:41.517 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 18:08:41.520 CNTRLR « [Node 008] received wakeup notification 18:08:41.521 CNTRLR [Node 008] The node is now awake. 18:08:42.522 CNTRLR » [Node 008] Sending node back to sleep... 18:08:42.527 SERIAL » 0x0109001308028408253076 (11 bytes) 18:08:42.527 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 48 └─[WakeUpCCNoMoreInformation] 18:08:42.530 SERIAL « [ACK] (0x06) 18:08:42.535 SERIAL « 0x0104011301e8 (6 bytes) 18:08:42.536 SERIAL » [ACK] (0x06) 18:08:42.537 DRIVER « [RES] [SendData] was sent: true 18:08:42.553 SERIAL « 0x0107001330000002d9 (9 bytes) 18:08:42.554 SERIAL » [ACK] (0x06) 18:08:42.555 DRIVER « [REQ] [SendData] callback id: 48 transmit status: OK 18:08:42.561 CNTRLR [Node 008] The node is now asleep. 18:08:45.940 SERIAL « 0x010c00040007063105012200bd5c (14 bytes) 18:08:45.941 CNTRLR [Node 007] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 18:08:45.942 CNTRLR [Node 007] [~] [Multilevel Sensor] Air temperature: 19 => 18.9 [Endpoint 0] 18:08:45.943 SERIAL » [ACK] (0x06) 18:08:45.944 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.9 18:08:46.120 SERIAL « 0x010b0004000705310505014280 (13 bytes) 18:08:46.120 CNTRLR [Node 007] [Multilevel Sensor] Humidity: metadata updated [Endpoint 0] 18:08:46.121 CNTRLR [Node 007] [~] [Multilevel Sensor] Humidity: 69 => 66 [Endpoint 0] 18:08:46.121 SERIAL » [ACK] (0x06) 18:08:46.122 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Humidity scale: Percentage value value: 66 18:08:46.881 SERIAL « 0x010900040008033003ff35 (11 bytes) 18:08:46.882 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:08:46.883 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:08:46.884 SERIAL » [ACK] (0x06) 18:08:46.886 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:08:46.978 SERIAL « 0x0109000400070380036411 (11 bytes) 18:08:46.979 CNTRLR [Node 007] [~] [Battery] level: 100 => 100 [Endpoint 0] 18:08:46.980 CNTRLR [Node 007] [~] [Battery] isLow: false => false [Endpoint 0] 18:08:46.980 SERIAL » [ACK] (0x06) 18:08:46.982 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 18:08:47.080 SERIAL « 0x010c00040007063105030a0000cb (14 bytes) 18:08:47.081 CNTRLR [Node 007] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 18:08:47.082 CNTRLR [Node 007] [~] [Multilevel Sensor] Illuminance: 0 => 0 [Endpoint 0] 18:08:47.083 SERIAL » [ACK] (0x06) 18:08:47.084 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 0 18:08:47.220 SERIAL « 0x010b000400070531051b0100dc (13 bytes) 18:08:47.221 CNTRLR [Node 007] [Multilevel Sensor] Ultraviolet: metadata updated [Endpoint 0] 18:08:47.222 CNTRLR [Node 007] [~] [Multilevel Sensor] Ultraviolet: 0 => 0 [Endpoint 0] 18:08:47.222 SERIAL » [ACK] (0x06) 18:08:47.224 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Ultraviolet scale: UV index value: 0 18:08:47.451 SERIAL « 0x010900040008032001ff27 (11 bytes) 18:08:47.452 SERIAL » [ACK] (0x06) 18:08:47.452 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:08:47.453 CNTRLR [Node 008] treating BasicCC Set as a report 18:08:47.454 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:08:51.416 SERIAL « 0x01090004001b03300300d9 (11 bytes) 18:08:51.417 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:08:51.418 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:08:51.419 SERIAL » [ACK] (0x06) 18:08:51.422 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:08:51.470 SERIAL « 0x01090004001b03200100cb (11 bytes) 18:08:51.471 SERIAL » [ACK] (0x06) 18:08:51.472 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:08:51.474 CNTRLR [Node 027] treating BasicCC Set as a report 18:08:51.475 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:08:58.139 SERIAL « 0x010c00040003063105042208ac44 (14 bytes) 18:08:58.140 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:08:58.140 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 112.3 => 222 [Endpoint 0] 18:08:58.141 SERIAL » [ACK] (0x06) 18:08:58.142 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 222 18:08:59.139 SERIAL « 0x010c00040003063105042203de3d (14 bytes) 18:08:59.145 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:08:59.146 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 222 => 99 [Endpoint 0] 18:08:59.147 SERIAL » [ACK] (0x06) 18:08:59.149 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 99 18:09:00.139 SERIAL « 0x010c000400030631050422047e9a (14 bytes) 18:09:00.140 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:09:00.141 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 99 => 115 [Endpoint 0] 18:09:00.142 SERIAL » [ACK] (0x06) 18:09:00.143 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 115 18:09:01.139 SERIAL « 0x010c00040003063105042209a24b (14 bytes) 18:09:01.141 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:09:01.142 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 115 => 246.6 [Endpoint 0] 18:09:01.143 SERIAL » [ACK] (0x06) 18:09:01.145 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 246.6 18:09:09.140 SERIAL « 0x010c000400030631050422047397 (14 bytes) 18:09:09.141 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:09:09.141 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 246.6 => 113.9 [Endpoint 0] 18:09:09.142 SERIAL » [ACK] (0x06) 18:09:09.143 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 113.9 18:09:35.440 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 18:09:35.440 SERIAL » [ACK] (0x06) 18:09:35.442 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 18:09:35.444 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 18:09:41.161 SERIAL « 0x01090004001b033003ff26 (11 bytes) 18:09:41.163 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:09:41.164 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:09:41.165 SERIAL » [ACK] (0x06) 18:09:41.166 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:09:41.216 SERIAL « 0x01090004001b032001ff34 (11 bytes) 18:09:41.217 SERIAL » [ACK] (0x06) 18:09:41.219 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:09:41.221 CNTRLR [Node 027] treating BasicCC Set as a report 18:09:41.222 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:09:42.571 SERIAL « 0x010900040015033003ff28 (11 bytes) 18:09:42.574 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:09:42.578 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:09:42.579 SERIAL » [ACK] (0x06) 18:09:42.580 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:09:42.626 SERIAL « 0x010900040015032001ff3a (11 bytes) 18:09:42.627 SERIAL » [ACK] (0x06) 18:09:42.628 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:09:42.630 CNTRLR [Node 021] treating BasicCC Set as a report 18:09:42.630 CNTRLR [Node 021] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:09:46.935 SERIAL « 0x01080004001102840763 (10 bytes) 18:09:46.936 SERIAL » [ACK] (0x06) 18:09:46.937 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 18:09:46.939 CNTRLR « [Node 017] received wakeup notification 18:09:46.940 CNTRLR [Node 017] The node is now awake. 18:09:47.941 CNTRLR » [Node 017] Sending node back to sleep... 18:09:47.945 SERIAL » 0x010900131102840825316e (11 bytes) 18:09:47.946 DRIVER » [Node 017] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 49 └─[WakeUpCCNoMoreInformation] 18:09:47.948 SERIAL « [ACK] (0x06) 18:09:47.954 SERIAL « 0x0104011301e8 (6 bytes) 18:09:47.955 SERIAL » [ACK] (0x06) 18:09:47.955 DRIVER « [RES] [SendData] was sent: true 18:09:47.971 SERIAL « 0x0107001331000002d8 (9 bytes) 18:09:47.972 SERIAL » [ACK] (0x06) 18:09:47.972 DRIVER « [REQ] [SendData] callback id: 49 transmit status: OK 18:09:47.975 CNTRLR [Node 017] The node is now asleep. 18:09:51.398 SERIAL « 0x01090004001e033003ff23 (11 bytes) 18:09:51.399 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:09:51.400 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:09:51.401 SERIAL » [ACK] (0x06) 18:09:51.403 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:09:51.452 SERIAL « 0x01090004001e032001ff31 (11 bytes) 18:09:51.453 SERIAL » [ACK] (0x06) 18:09:51.454 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:09:51.456 CNTRLR [Node 030] treating BasicCC Set as a report 18:09:51.457 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:09:51.766 SERIAL « 0x01080004001b02840769 (10 bytes) 18:09:51.767 SERIAL » [ACK] (0x06) 18:09:51.768 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 18:09:51.770 CNTRLR « [Node 027] received wakeup notification 18:09:51.771 CNTRLR [Node 027] The node is now awake. 18:09:52.773 CNTRLR » [Node 027] Sending node back to sleep... 18:09:52.777 SERIAL » 0x010900131b028408253267 (11 bytes) 18:09:52.777 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 50 └─[WakeUpCCNoMoreInformation] 18:09:52.778 SERIAL « [ACK] (0x06) 18:09:52.785 SERIAL « 0x0104011301e8 (6 bytes) 18:09:52.785 SERIAL » [ACK] (0x06) 18:09:52.786 DRIVER « [RES] [SendData] was sent: true 18:09:52.802 SERIAL « 0x0107001332000002db (9 bytes) 18:09:52.802 SERIAL » [ACK] (0x06) 18:09:52.803 DRIVER « [REQ] [SendData] callback id: 50 transmit status: OK 18:09:52.805 CNTRLR [Node 027] The node is now asleep. 18:09:57.780 SERIAL « 0x010c0004000a06310504220000e9 (14 bytes) 18:09:57.781 CNTRLR [Node 010] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:09:57.782 CNTRLR [Node 010] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 18:09:57.783 SERIAL » [ACK] (0x06) 18:09:57.785 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 18:09:57.788 CNTRLR [Node 010] The node is now alive. 18:09:57.789 CNTRLR [Node 010] Beginning interview - last completed stage: RestartFromCache 18:09:57.790 CNTRLR » [Node 010] pinging the node... 18:09:57.795 CNTRLR [Node 010] The node is ready to be used 18:09:57.803 SERIAL » 0x010800130a01002533f9 (10 bytes) 18:09:57.804 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 51 └─[NoOperationCC] 18:09:57.809 SERIAL « [ACK] (0x06) 18:09:57.816 SERIAL « 0x0104011301e8 (6 bytes) 18:09:57.818 SERIAL » [ACK] (0x06) 18:09:57.819 DRIVER « [RES] [SendData] was sent: true 18:09:57.834 SERIAL « 0x0107001333000002da (9 bytes) 18:09:57.835 SERIAL » [ACK] (0x06) 18:09:57.836 DRIVER « [REQ] [SendData] callback id: 51 transmit status: OK 18:09:57.840 CNTRLR « [Node 010] ping successful 18:09:57.847 CNTRLR [Node 010] ManufacturerSpecificCC: doing a partial interview... 18:09:57.848 CNTRLR [Node 010] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 18:09:57.888 CNTRLR [Node 010] VersionCC: doing a partial interview... 18:09:57.888 CNTRLR [Node 010] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 18:09:57.890 CNTRLR [Node 010] trying to load device config 18:09:58.166 CNTRLR [Node 010] device config loaded 18:09:58.200 CNTRLR [Node 010] AssociationCC: doing a partial interview... 18:09:58.201 CNTRLR [Node 010] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 18:09:58.202 CNTRLR [Node 010] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 18:09:58.203 CNTRLR [Node 010] BinarySwitchCC: doing a partial interview... 18:09:58.203 CNTRLR » [Node 010] querying Binary Switch state... 18:09:58.208 SERIAL » 0x010900130a0225022534db (11 bytes) 18:09:58.209 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 52 └─[BinarySwitchCCGet] 18:09:58.211 SERIAL « [ACK] (0x06) 18:09:58.217 SERIAL « 0x0104011301e8 (6 bytes) 18:09:58.217 SERIAL » [ACK] (0x06) 18:09:58.218 DRIVER « [RES] [SendData] was sent: true 18:09:58.235 SERIAL « 0x0107001334000002dd (9 bytes) 18:09:58.236 SERIAL » [ACK] (0x06) 18:09:58.237 DRIVER « [REQ] [SendData] callback id: 52 transmit status: OK 18:09:58.244 SERIAL « 0x01090004000a03250300dd (11 bytes) 18:09:58.245 CNTRLR [Node 010] [~] [Binary Switch] currentValue: true => false [Endpoint 0] 18:09:58.246 SERIAL » [ACK] (0x06) 18:09:58.247 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 18:09:58.248 CNTRLR « [Node 010] received Binary Switch state: current value: false 18:09:58.248 CNTRLR [Node 010] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 18:09:58.249 CNTRLR [Node 010] MultilevelSensorCC: doing a partial interview... 18:09:58.249 CNTRLR » [Node 010] querying current sensor reading... 18:09:58.252 SERIAL » 0x010900130a0231042535c8 (11 bytes) 18:09:58.253 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 53 └─[MultilevelSensorCCGet] 18:09:58.255 SERIAL « [ACK] (0x06) 18:09:58.261 SERIAL « 0x0104011301e8 (6 bytes) 18:09:58.262 SERIAL » [ACK] (0x06) 18:09:58.264 DRIVER « [RES] [SendData] was sent: true 18:09:58.278 SERIAL « 0x0107001335000003dd (9 bytes) 18:09:58.278 SERIAL » [ACK] (0x06) 18:09:58.279 DRIVER « [REQ] [SendData] callback id: 53 transmit status: OK 18:09:58.289 SERIAL « 0x010c0004000a06310504220000e9 (14 bytes) 18:09:58.289 CNTRLR [Node 010] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:09:58.290 CNTRLR [Node 010] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 18:09:58.290 SERIAL » [ACK] (0x06) 18:09:58.291 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 18:09:58.294 CNTRLR « [Node 010] received current sensor reading: sensor type: Power value: 0 W 18:09:58.295 CNTRLR [Node 010] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 18:09:58.295 CNTRLR [Node 010] MeterCC: doing a partial interview... 18:09:58.295 CNTRLR » [Node 010] querying default meter value... 18:09:58.300 SERIAL » 0x010900130a0232012536cd (11 bytes) 18:09:58.300 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 54 └─[MeterCCGet] 18:09:58.302 SERIAL « [ACK] (0x06) 18:09:58.308 SERIAL « 0x0104011301e8 (6 bytes) 18:09:58.308 SERIAL » [ACK] (0x06) 18:09:58.309 DRIVER « [RES] [SendData] was sent: true 18:09:58.326 SERIAL « 0x0107001336000002df (9 bytes) 18:09:58.326 SERIAL » [ACK] (0x06) 18:09:58.327 DRIVER « [REQ] [SendData] callback id: 54 transmit status: OK 18:09:58.337 SERIAL « 0x010e0004000a083202014400000669ed (16 bytes) 18:09:58.338 CNTRLR [Node 010] [~] [Meter] value[65536]: 13.45 => 16.41 [Endpoint 0] 18:09:58.338 CNTRLR [Node 010] [~] [Meter] deltaTime[65536]: 0 => 0 [Endpoint 0] 18:09:58.339 SERIAL » [ACK] (0x06) 18:09:58.340 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Unspecified value: 16.41 time delta: 0 seconds 18:09:58.341 CNTRLR [Node 010] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 18:09:58.342 CNTRLR [Node 010] ConfigurationCC: Loading configuration parameters from device confi g 18:09:58.347 CNTRLR [Node 010] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 18:09:58.348 CNTRLR [Node 010] [Configuration] 1: metadata updated 18:09:58.349 CNTRLR [Node 010] [Configuration] 16: metadata updated 18:09:58.350 CNTRLR [Node 010] [Configuration] 34: metadata updated 18:09:58.351 CNTRLR [Node 010] [Configuration] 35: metadata updated 18:09:58.351 CNTRLR [Node 010] [Configuration] 39: metadata updated 18:09:58.355 CNTRLR [Node 010] [Configuration] 40: metadata updated 18:09:58.355 CNTRLR [Node 010] [Configuration] 42: metadata updated 18:09:58.356 CNTRLR [Node 010] [Configuration] 43: metadata updated 18:09:58.357 CNTRLR [Node 010] [Configuration] 45: metadata updated 18:09:58.358 CNTRLR [Node 010] [Configuration] 47: metadata updated 18:09:58.358 CNTRLR [Node 010] [Configuration] 49: metadata updated 18:09:58.359 CNTRLR [Node 010] [Configuration] 50: metadata updated 18:09:58.360 CNTRLR [Node 010] [Configuration] 51: metadata updated 18:09:58.361 CNTRLR [Node 010] [Configuration] 52: metadata updated 18:09:58.362 CNTRLR [Node 010] [Configuration] 60: metadata updated 18:09:58.362 CNTRLR [Node 010] [Configuration] 61: metadata updated 18:09:58.363 CNTRLR [Node 010] [Configuration] 62: metadata updated 18:09:58.364 CNTRLR [Node 010] [Configuration] 63: metadata updated 18:09:58.366 CNTRLR [Node 010] [Configuration] 70: metadata updated 18:09:58.367 CNTRLR [Node 010] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 18:09:58.368 CNTRLR » [Node 010] querying parameter #1 value... 18:09:58.372 SERIAL » 0x010a00130a03700501253789 (12 bytes) 18:09:58.372 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 55 └─[ConfigurationCCGet] parameter #: 1 18:09:58.379 SERIAL « [ACK] (0x06) 18:09:58.413 SERIAL « 0x0104011301e8 (6 bytes) 18:09:58.414 SERIAL » [ACK] (0x06) 18:09:58.425 DRIVER « [RES] [SendData] was sent: true 18:09:58.434 SERIAL « 0x0107001337000003df (9 bytes) 18:09:58.436 SERIAL » [ACK] (0x06) 18:09:58.438 DRIVER « [REQ] [SendData] callback id: 55 transmit status: OK 18:09:58.444 SERIAL « 0x010b0004000a05700601010188 (13 bytes) 18:09:58.449 CNTRLR [Node 010] [~] [Configuration] 1: 1 => 1 18:09:58.450 SERIAL » [ACK] (0x06) 18:09:58.452 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 1 18:09:58.453 CNTRLR « [Node 010] parameter #1 has value: 1 18:09:58.454 CNTRLR » [Node 010] querying parameter #16 value... 18:09:58.458 SERIAL » 0x010a00130a03700510253897 (12 bytes) 18:09:58.458 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 56 └─[ConfigurationCCGet] parameter #: 16 18:09:58.463 SERIAL « [ACK] (0x06) 18:09:58.466 SERIAL « 0x0104011301e8 (6 bytes) 18:09:58.467 SERIAL » [ACK] (0x06) 18:09:58.467 DRIVER « [RES] [SendData] was sent: true 18:09:58.484 SERIAL « 0x0107001338000002d1 (9 bytes) 18:09:58.484 SERIAL » [ACK] (0x06) 18:09:58.485 DRIVER « [REQ] [SendData] callback id: 56 transmit status: OK 18:09:58.494 SERIAL « 0x010b0004000a05700610010199 (13 bytes) 18:09:58.501 CNTRLR [Node 010] [~] [Configuration] 16: 1 => 1 18:09:58.503 SERIAL » [ACK] (0x06) 18:09:58.504 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 1 18:09:58.505 CNTRLR « [Node 010] parameter #16 has value: 1 18:09:58.506 CNTRLR » [Node 010] querying parameter #34 value... 18:09:58.510 SERIAL » 0x010a00130a037005222539a4 (12 bytes) 18:09:58.511 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 57 └─[ConfigurationCCGet] parameter #: 34 18:09:58.523 SERIAL « [ACK] (0x06) 18:09:58.524 SERIAL « 0x0104011301e8 (6 bytes) 18:09:58.524 SERIAL » [ACK] (0x06) 18:09:58.527 DRIVER « [RES] [SendData] was sent: true 18:09:58.536 SERIAL « 0x0107001339000003d1 (9 bytes) 18:09:58.537 SERIAL » [ACK] (0x06) 18:09:58.537 DRIVER « [REQ] [SendData] callback id: 57 transmit status: OK 18:09:58.547 SERIAL « 0x010b0004000a05700622013f95 (13 bytes) 18:09:58.552 CNTRLR [Node 010] [~] [Configuration] 34: 63 => 63 18:09:58.553 SERIAL » [ACK] (0x06) 18:09:58.554 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 34 value size: 1 value: 63 18:09:58.555 CNTRLR « [Node 010] parameter #34 has value: 63 18:09:58.555 CNTRLR » [Node 010] querying parameter #35 value... 18:09:58.559 SERIAL » 0x010a00130a03700523253aa6 (12 bytes) 18:09:58.559 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 58 └─[ConfigurationCCGet] parameter #: 35 18:09:58.562 SERIAL « [ACK] (0x06) 18:09:58.567 SERIAL « 0x0104011301e8 (6 bytes) 18:09:58.568 SERIAL » [ACK] (0x06) 18:09:58.569 DRIVER « [RES] [SendData] was sent: true 18:09:58.584 SERIAL « 0x010700133a000002d3 (9 bytes) 18:09:58.585 SERIAL » [ACK] (0x06) 18:09:58.585 DRIVER « [REQ] [SendData] callback id: 58 transmit status: OK 18:09:58.595 SERIAL « 0x010b0004000a057006230100ab (13 bytes) 18:09:58.600 CNTRLR [Node 010] [~] [Configuration] 35: 0 => 0 18:09:58.601 SERIAL » [ACK] (0x06) 18:09:58.601 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 0 18:09:58.602 CNTRLR « [Node 010] parameter #35 has value: 0 18:09:58.603 CNTRLR » [Node 010] querying parameter #39 value... 18:09:58.606 SERIAL » 0x010a00130a03700527253ba3 (12 bytes) 18:09:58.607 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 59 └─[ConfigurationCCGet] parameter #: 39 18:09:58.609 SERIAL « [ACK] (0x06) 18:09:58.615 SERIAL « 0x0104011301e8 (6 bytes) 18:09:58.615 SERIAL » [ACK] (0x06) 18:09:58.616 DRIVER « [RES] [SendData] was sent: true 18:09:58.632 SERIAL « 0x010700133b000002d2 (9 bytes) 18:09:58.633 SERIAL » [ACK] (0x06) 18:09:58.633 DRIVER « [REQ] [SendData] callback id: 59 transmit status: OK 18:09:58.643 SERIAL « 0x010c0004000a06700627020258f2 (14 bytes) 18:09:58.648 CNTRLR [Node 010] [~] [Configuration] 39: 600 => 600 18:09:58.649 SERIAL » [ACK] (0x06) 18:09:58.650 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 39 value size: 2 value: 600 18:09:58.651 CNTRLR « [Node 010] parameter #39 has value: 600 18:09:58.651 CNTRLR » [Node 010] querying parameter #40 value... 18:09:58.654 SERIAL » 0x010a00130a03700528253cab (12 bytes) 18:09:58.655 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 60 └─[ConfigurationCCGet] parameter #: 40 18:09:58.657 SERIAL « [ACK] (0x06) 18:09:58.663 SERIAL « 0x0104011301e8 (6 bytes) 18:09:58.663 SERIAL » [ACK] (0x06) 18:09:58.664 DRIVER « [RES] [SendData] was sent: true 18:09:58.680 SERIAL « 0x010700133c000002d5 (9 bytes) 18:09:58.681 SERIAL » [ACK] (0x06) 18:09:58.681 DRIVER « [REQ] [SendData] callback id: 60 transmit status: OK 18:09:58.690 SERIAL « 0x010b0004000a057006280150f0 (13 bytes) 18:09:58.696 CNTRLR [Node 010] [~] [Configuration] 40: 80 => 80 18:09:58.696 SERIAL » [ACK] (0x06) 18:09:58.697 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 80 18:09:58.698 CNTRLR « [Node 010] parameter #40 has value: 80 18:09:58.698 CNTRLR » [Node 010] querying parameter #42 value... 18:09:58.702 SERIAL » 0x010a00130a0370052a253da8 (12 bytes) 18:09:58.702 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 61 └─[ConfigurationCCGet] parameter #: 42 18:09:58.705 SERIAL « [ACK] (0x06) 18:09:58.710 SERIAL « 0x0104011301e8 (6 bytes) 18:09:58.711 SERIAL » [ACK] (0x06) 18:09:58.711 DRIVER « [RES] [SendData] was sent: true 18:09:58.727 SERIAL « 0x010700133d000003d5 (9 bytes) 18:09:58.728 SERIAL » [ACK] (0x06) 18:09:58.728 DRIVER « [REQ] [SendData] callback id: 61 transmit status: OK 18:09:58.738 SERIAL « 0x010b0004000a0570062a010fad (13 bytes) 18:09:58.743 CNTRLR [Node 010] [~] [Configuration] 42: 15 => 15 18:09:58.743 SERIAL » [ACK] (0x06) 18:09:58.745 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 15 18:09:58.746 CNTRLR « [Node 010] parameter #42 has value: 15 18:09:58.746 CNTRLR » [Node 010] querying parameter #43 value... 18:09:58.754 SERIAL » 0x010a00130a0370052b253eaa (12 bytes) 18:09:58.754 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 62 └─[ConfigurationCCGet] parameter #: 43 18:09:58.757 SERIAL « [ACK] (0x06) 18:09:58.762 SERIAL « 0x0104011301e8 (6 bytes) 18:09:58.762 SERIAL » [ACK] (0x06) 18:09:58.763 DRIVER « [RES] [SendData] was sent: true 18:09:58.780 SERIAL « 0x010700133e000002d7 (9 bytes) 18:09:58.780 SERIAL » [ACK] (0x06) 18:09:58.781 DRIVER « [REQ] [SendData] callback id: 62 transmit status: OK 18:09:58.790 SERIAL « 0x010b0004000a0570062b011ebd (13 bytes) 18:09:58.795 CNTRLR [Node 010] [~] [Configuration] 43: 30 => 30 18:09:58.795 SERIAL » [ACK] (0x06) 18:09:58.796 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 30 18:09:58.797 CNTRLR « [Node 010] parameter #43 has value: 30 18:09:58.797 CNTRLR » [Node 010] querying parameter #45 value... 18:09:58.801 SERIAL » 0x010a00130a0370052d253fad (12 bytes) 18:09:58.801 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 63 └─[ConfigurationCCGet] parameter #: 45 18:09:58.804 SERIAL « [ACK] (0x06) 18:09:58.817 SERIAL « 0x0104011301e8 (6 bytes) 18:09:58.817 SERIAL » [ACK] (0x06) 18:09:58.818 DRIVER « [RES] [SendData] was sent: true 18:09:58.821 SERIAL « 0x01100004000a0a32022144000006690000d1 (18 bytes) 18:09:58.821 CNTRLR [Node 010] [~] [Meter] value[65537]: 16.41 => 16.41 [Endpoint 0] 18:09:58.822 CNTRLR [Node 010] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 18:09:58.822 SERIAL » [ACK] (0x06) 18:09:58.824 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 16.41 time delta: 0 seconds 18:09:58.836 SERIAL « 0x010700133f000002d6 (9 bytes) 18:09:58.836 SERIAL » [ACK] (0x06) 18:09:58.836 DRIVER « [REQ] [SendData] callback id: 63 transmit status: OK 18:09:58.846 SERIAL « 0x010b0004000a0570062d010aaf (13 bytes) 18:09:58.851 CNTRLR [Node 010] [~] [Configuration] 45: 10 => 10 18:09:58.852 SERIAL » [ACK] (0x06) 18:09:58.852 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 45 value size: 1 value: 10 18:09:58.853 CNTRLR « [Node 010] parameter #45 has value: 10 18:09:58.854 CNTRLR » [Node 010] querying parameter #47 value... 18:09:58.857 SERIAL » 0x010a00130a0370052f2540d0 (12 bytes) 18:09:58.857 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 64 └─[ConfigurationCCGet] parameter #: 47 18:09:58.860 SERIAL « [ACK] (0x06) 18:09:58.865 SERIAL « 0x0104011301e8 (6 bytes) 18:09:58.866 SERIAL » [ACK] (0x06) 18:09:58.866 DRIVER « [RES] [SendData] was sent: true 18:09:58.883 SERIAL « 0x0107001340000002a9 (9 bytes) 18:09:58.883 SERIAL » [ACK] (0x06) 18:09:58.884 DRIVER « [REQ] [SendData] callback id: 64 transmit status: OK 18:09:58.894 SERIAL « 0x010c0004000a0670062f020e10be (14 bytes) 18:09:58.899 CNTRLR [Node 010] [~] [Configuration] 47: 3600 => 3600 18:09:58.899 SERIAL » [ACK] (0x06) 18:09:58.900 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 47 value size: 2 value: 3600 18:09:58.901 CNTRLR « [Node 010] parameter #47 has value: 3600 18:09:58.901 CNTRLR » [Node 010] querying parameter #49 value... 18:09:58.905 SERIAL » 0x010a00130a037005312541cf (12 bytes) 18:09:58.905 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 65 └─[ConfigurationCCGet] parameter #: 49 18:09:58.908 SERIAL « [ACK] (0x06) 18:09:58.915 SERIAL « 0x0104011301e8 (6 bytes) 18:09:58.916 SERIAL » [ACK] (0x06) 18:09:58.918 DRIVER « [RES] [SendData] was sent: true 18:09:58.931 SERIAL « 0x0107001341000002a8 (9 bytes) 18:09:58.931 SERIAL » [ACK] (0x06) 18:09:58.932 DRIVER « [REQ] [SendData] callback id: 65 transmit status: OK 18:09:58.941 SERIAL « 0x010b0004000a057006310100b9 (13 bytes) 18:09:58.946 CNTRLR [Node 010] [~] [Configuration] 49: 0 => 0 18:09:58.947 SERIAL » [ACK] (0x06) 18:09:58.947 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 49 value size: 1 value: 0 18:09:58.949 CNTRLR « [Node 010] parameter #49 has value: 0 18:09:58.949 CNTRLR » [Node 010] querying parameter #50 value... 18:09:58.952 SERIAL » 0x010a00130a037005322542cf (12 bytes) 18:09:58.952 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 66 └─[ConfigurationCCGet] parameter #: 50 18:09:58.956 SERIAL « [ACK] (0x06) 18:09:58.960 SERIAL « 0x0104011301e8 (6 bytes) 18:09:58.961 SERIAL » [ACK] (0x06) 18:09:58.961 DRIVER « [RES] [SendData] was sent: true 18:09:58.978 SERIAL « 0x0107001342000003aa (9 bytes) 18:09:58.978 SERIAL » [ACK] (0x06) 18:09:58.979 DRIVER « [REQ] [SendData] callback id: 66 transmit status: OK 18:09:58.989 SERIAL « 0x010c0004000a0670063202012c90 (14 bytes) 18:09:58.994 CNTRLR [Node 010] [~] [Configuration] 50: 300 => 300 18:09:58.994 SERIAL » [ACK] (0x06) 18:09:58.995 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 2 value: 300 18:09:58.996 CNTRLR « [Node 010] parameter #50 has value: 300 18:09:58.996 CNTRLR » [Node 010] querying parameter #51 value... 18:09:59.002 SERIAL » 0x010a00130a037005332543cf (12 bytes) 18:09:59.002 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 67 └─[ConfigurationCCGet] parameter #: 51 18:09:59.005 SERIAL « [ACK] (0x06) 18:09:59.010 SERIAL « 0x0104011301e8 (6 bytes) 18:09:59.011 SERIAL » [ACK] (0x06) 18:09:59.011 DRIVER « [RES] [SendData] was sent: true 18:09:59.028 SERIAL « 0x0107001343000003ab (9 bytes) 18:09:59.028 SERIAL » [ACK] (0x06) 18:09:59.029 DRIVER « [REQ] [SendData] callback id: 67 transmit status: OK 18:09:59.038 SERIAL « 0x010c0004000a067006330201f449 (14 bytes) 18:09:59.043 CNTRLR [Node 010] [~] [Configuration] 51: 500 => 500 18:09:59.044 SERIAL » [ACK] (0x06) 18:09:59.045 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 51 value size: 2 value: 500 18:09:59.046 CNTRLR « [Node 010] parameter #51 has value: 500 18:09:59.046 CNTRLR » [Node 010] querying parameter #52 value... 18:09:59.049 SERIAL » 0x010a00130a037005342544cf (12 bytes) 18:09:59.050 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 68 └─[ConfigurationCCGet] parameter #: 52 18:09:59.052 SERIAL « [ACK] (0x06) 18:09:59.058 SERIAL « 0x0104011301e8 (6 bytes) 18:09:59.058 SERIAL » [ACK] (0x06) 18:09:59.058 DRIVER « [RES] [SendData] was sent: true 18:09:59.076 SERIAL « 0x0107001344000002ad (9 bytes) 18:09:59.076 SERIAL » [ACK] (0x06) 18:09:59.077 DRIVER « [REQ] [SendData] callback id: 68 transmit status: OK 18:09:59.086 SERIAL « 0x010b0004000a057006340106ba (13 bytes) 18:09:59.091 CNTRLR [Node 010] [~] [Configuration] 52: 6 => 6 18:09:59.092 SERIAL » [ACK] (0x06) 18:09:59.093 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 52 value size: 1 value: 6 18:09:59.094 CNTRLR « [Node 010] parameter #52 has value: 6 18:09:59.095 CNTRLR » [Node 010] querying parameter #60 value... 18:09:59.099 SERIAL » 0x010a00130a0370053c2545c6 (12 bytes) 18:09:59.099 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 69 └─[ConfigurationCCGet] parameter #: 60 18:09:59.102 SERIAL « [ACK] (0x06) 18:09:59.109 SERIAL « 0x0104011301e8 (6 bytes) 18:09:59.110 SERIAL » [ACK] (0x06) 18:09:59.112 DRIVER « [RES] [SendData] was sent: true 18:09:59.125 SERIAL « 0x0107001345000002ac (9 bytes) 18:09:59.127 SERIAL » [ACK] (0x06) 18:09:59.128 DRIVER « [REQ] [SendData] callback id: 69 transmit status: OK 18:09:59.135 SERIAL « 0x010c0004000a0670063c0261a87a (14 bytes) 18:09:59.140 CNTRLR [Node 010] [~] [Configuration] 60: 25000 => 25000 18:09:59.141 SERIAL » [ACK] (0x06) 18:09:59.142 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 2 value: 25000 18:09:59.143 CNTRLR « [Node 010] parameter #60 has value: 25000 18:09:59.143 CNTRLR » [Node 010] querying parameter #61 value... 18:09:59.166 SERIAL » 0x010a00130a0370053d2546c4 (12 bytes) 18:09:59.166 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 70 └─[ConfigurationCCGet] parameter #: 61 18:09:59.169 SERIAL « [ACK] (0x06) 18:09:59.175 SERIAL « 0x0104011301e8 (6 bytes) 18:09:59.175 SERIAL » [ACK] (0x06) 18:09:59.176 DRIVER « [RES] [SendData] was sent: true 18:09:59.191 SERIAL « 0x0107001346000002af (9 bytes) 18:09:59.192 SERIAL » [ACK] (0x06) 18:09:59.192 DRIVER « [REQ] [SendData] callback id: 70 transmit status: OK 18:09:59.202 SERIAL « 0x010b0004000a0570063d0101b4 (13 bytes) 18:09:59.207 CNTRLR [Node 010] [~] [Configuration] 61: 1 => 1 18:09:59.207 SERIAL » [ACK] (0x06) 18:09:59.208 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 61 value size: 1 value: 1 18:09:59.209 CNTRLR « [Node 010] parameter #61 has value: 1 18:09:59.209 CNTRLR » [Node 010] querying parameter #62 value... 18:09:59.213 SERIAL » 0x010a00130a0370053e2547c6 (12 bytes) 18:09:59.213 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 71 └─[ConfigurationCCGet] parameter #: 62 18:09:59.216 SERIAL « [ACK] (0x06) 18:09:59.221 SERIAL « 0x0104011301e8 (6 bytes) 18:09:59.222 SERIAL » [ACK] (0x06) 18:09:59.222 DRIVER « [RES] [SendData] was sent: true 18:09:59.238 SERIAL « 0x0107001347000003af (9 bytes) 18:09:59.239 SERIAL » [ACK] (0x06) 18:09:59.239 DRIVER « [REQ] [SendData] callback id: 71 transmit status: OK 18:09:59.249 SERIAL « 0x010b0004000a0570063e0108be (13 bytes) 18:09:59.254 CNTRLR [Node 010] [~] [Configuration] 62: 8 => 8 18:09:59.255 SERIAL » [ACK] (0x06) 18:09:59.256 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 62 value size: 1 value: 8 18:09:59.259 CNTRLR « [Node 010] parameter #62 has value: 8 18:09:59.260 CNTRLR » [Node 010] querying parameter #63 value... 18:09:59.263 SERIAL » 0x010a00130a0370053f2548c8 (12 bytes) 18:09:59.263 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 72 └─[ConfigurationCCGet] parameter #: 63 18:09:59.270 SERIAL « [ACK] (0x06) 18:09:59.273 SERIAL « 0x0104011301e8 (6 bytes) 18:09:59.274 SERIAL » [ACK] (0x06) 18:09:59.278 DRIVER « [RES] [SendData] was sent: true 18:09:59.290 SERIAL « 0x0107001348000002a1 (9 bytes) 18:09:59.290 SERIAL » [ACK] (0x06) 18:09:59.291 DRIVER « [REQ] [SendData] callback id: 72 transmit status: OK 18:09:59.299 SERIAL « 0x010b0004000a0570063f0101b6 (13 bytes) 18:09:59.307 CNTRLR [Node 010] [~] [Configuration] 63: 1 => 1 18:09:59.308 SERIAL » [ACK] (0x06) 18:09:59.309 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 63 value size: 1 value: 1 18:09:59.310 CNTRLR « [Node 010] parameter #63 has value: 1 18:09:59.310 CNTRLR » [Node 010] querying parameter #70 value... 18:09:59.315 SERIAL » 0x010a00130a037005462549b0 (12 bytes) 18:09:59.316 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 73 └─[ConfigurationCCGet] parameter #: 70 18:09:59.319 SERIAL « [ACK] (0x06) 18:09:59.324 SERIAL « 0x0104011301e8 (6 bytes) 18:09:59.325 SERIAL » [ACK] (0x06) 18:09:59.326 DRIVER « [RES] [SendData] was sent: true 18:09:59.342 SERIAL « 0x0107001349000002a0 (9 bytes) 18:09:59.342 SERIAL » [ACK] (0x06) 18:09:59.344 DRIVER « [REQ] [SendData] callback id: 73 transmit status: OK 18:09:59.352 SERIAL « 0x010c0004000a0670064602ffffc9 (14 bytes) 18:09:59.359 CNTRLR [Node 010] [~] [Configuration] 70: 65535 => 65535 18:09:59.360 SERIAL » [ACK] (0x06) 18:09:59.362 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 70 value size: 2 value: 65535 18:09:59.364 CNTRLR « [Node 010] parameter #70 has value: 65535 18:09:59.364 CNTRLR [Node 010] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 18:09:59.405 CNTRLR [Node 010] MultiChannelAssociationCC: doing a partial interview... 18:09:59.405 CNTRLR » [Node 010] querying multi channel association group #1... 18:09:59.411 SERIAL » 0x010a00130a038e0201254a0d (12 bytes) 18:09:59.411 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 74 └─[MultiChannelAssociationCCGet] group id: 1 18:09:59.413 SERIAL « [ACK] (0x06) 18:09:59.421 SERIAL « 0x0104011301e8 (6 bytes) 18:09:59.422 SERIAL » [ACK] (0x06) 18:09:59.422 DRIVER « [RES] [SendData] was sent: true 18:09:59.437 SERIAL « 0x010700134a000003a2 (9 bytes) 18:09:59.438 SERIAL » [ACK] (0x06) 18:09:59.438 DRIVER « [REQ] [SendData] callback id: 74 transmit status: OK 18:09:59.447 SERIAL « 0x010b0004000a058e0301050076 (13 bytes) 18:09:59.448 SERIAL » [ACK] (0x06) 18:09:59.449 CNTRLR [Node 010] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 18:09:59.451 CNTRLR [Node 010] [~] [Multi Channel Association] nodeIds[1]: => 18:09:59.452 CNTRLR [Node 010] [~] [Multi Channel Association] endpoints[1]: => 18:09:59.453 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: endpoints: 18:09:59.454 CNTRLR « [Node 010] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 18:09:59.454 CNTRLR » [Node 010] querying multi channel association group #2... 18:09:59.458 SERIAL » 0x010a00130a038e0202254b0f (12 bytes) 18:09:59.458 DRIVER » [Node 010] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 75 └─[MultiChannelAssociationCCGet] group id: 2 18:09:59.461 SERIAL « [ACK] (0x06) 18:09:59.467 SERIAL « 0x0104011301e8 (6 bytes) 18:09:59.467 SERIAL » [ACK] (0x06) 18:09:59.469 DRIVER « [RES] [SendData] was sent: true 18:09:59.487 SERIAL « 0x010700134b000002a2 (9 bytes) 18:09:59.488 SERIAL » [ACK] (0x06) 18:09:59.488 DRIVER « [REQ] [SendData] callback id: 75 transmit status: OK 18:09:59.494 SERIAL « 0x010b0004000a058e0302050075 (13 bytes) 18:09:59.495 SERIAL » [ACK] (0x06) 18:09:59.496 CNTRLR [Node 010] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 18:09:59.496 CNTRLR [Node 010] [~] [Multi Channel Association] nodeIds[2]: => 18:09:59.497 CNTRLR [Node 010] [~] [Multi Channel Association] endpoints[2]: => 18:09:59.498 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 18:09:59.499 CNTRLR « [Node 010] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 18:09:59.500 CNTRLR [Node 010] [~] [Association] hasLifeline: true => true [internal] 18:09:59.500 CNTRLR [Node 010] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 18:09:59.500 CNTRLR [Node 010] Interview stage completed: CommandClasses 18:09:59.500 CNTRLR [Node 010] Interview stage completed: OverwriteConfig 18:09:59.500 CNTRLR » [Node 010] requesting node neighbors... 18:09:59.504 SERIAL » 0x010700800a00000072 (9 bytes) 18:09:59.504 DRIVER » [Node 010] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 18:09:59.508 SERIAL « [ACK] (0x06) 18:09:59.509 SERIAL « 0x01200180250d4c000000000000000000000000000000000000000000000000000 (34 bytes) 03a 18:09:59.509 SERIAL » [ACK] (0x06) 18:09:59.510 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 3, 6, 9, 11, 12, 19, 20, 23 18:09:59.512 CNTRLR « [Node 010] node neighbors received: 1, 3, 6, 9, 11, 12, 19, 20, 23 18:09:59.513 CNTRLR [Node 010] Interview stage completed: Neighbors 18:09:59.513 CNTRLR [Node 010] Interview completed 18:10:00.267 SERIAL « 0x01090004000a032503ff22 (11 bytes) 18:10:00.268 CNTRLR [Node 010] [~] [Binary Switch] currentValue: false => true [Endpoint 0] 18:10:00.269 SERIAL » [ACK] (0x06) 18:10:00.271 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: true 18:10:04.717 SERIAL « 0x01090004000a03250300dd (11 bytes) 18:10:04.719 CNTRLR [Node 010] [~] [Binary Switch] currentValue: true => false [Endpoint 0] 18:10:04.720 SERIAL » [ACK] (0x06) 18:10:04.721 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 18:10:06.077 SERIAL « 0x01090004000a032503ff22 (11 bytes) 18:10:06.078 CNTRLR [Node 010] [~] [Binary Switch] currentValue: false => true [Endpoint 0] 18:10:06.079 SERIAL » [ACK] (0x06) 18:10:06.081 DRIVER « [Node 010] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: true 18:10:11.500 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:10:11.502 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:11.503 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:10:11.504 SERIAL » [ACK] (0x06) 18:10:11.506 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:10:11.580 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:10:11.581 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:11.582 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:10:11.582 SERIAL » [ACK] (0x06) 18:10:11.583 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:10:11.645 SERIAL « 0x01090004002003200100f0 (11 bytes) 18:10:11.646 SERIAL » [ACK] (0x06) 18:10:11.647 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:10:11.648 CNTRLR [Node 032] treating BasicCC Set as a report 18:10:11.649 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:10:11.653 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:10:11.654 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:11.655 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:10:11.656 SERIAL » [ACK] (0x06) 18:10:11.657 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:10:11.792 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:10:11.793 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:11.794 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:10:11.795 SERIAL » [ACK] (0x06) 18:10:11.797 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:10:11.968 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:10:11.969 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:11.970 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:10:11.971 SERIAL » [ACK] (0x06) 18:10:11.972 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:10:11.985 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:10:11.986 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:11.987 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:10:11.988 SERIAL » [ACK] (0x06) 18:10:11.990 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:10:11.998 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:10:11.999 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:12.001 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:10:12.002 SERIAL » [ACK] (0x06) 18:10:12.003 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:10:12.015 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:10:12.016 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:12.017 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:10:12.018 SERIAL » [ACK] (0x06) 18:10:12.020 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:10:12.211 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:10:12.212 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:12.213 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:10:12.214 SERIAL » [ACK] (0x06) 18:10:12.220 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:10:12.228 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:10:12.229 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:12.230 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:10:12.232 SERIAL » [ACK] (0x06) 18:10:12.234 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:10:12.724 SERIAL « 0x01090004001503300300d7 (11 bytes) 18:10:12.724 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:12.725 CNTRLR [Node 021] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:10:12.725 SERIAL » [ACK] (0x06) 18:10:12.726 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:10:12.778 SERIAL « 0x01090004001503200100c5 (11 bytes) 18:10:12.779 SERIAL » [ACK] (0x06) 18:10:12.779 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:10:12.780 CNTRLR [Node 021] treating BasicCC Set as a report 18:10:12.781 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:10:17.314 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:10:17.315 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:17.316 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:10:17.317 SERIAL » [ACK] (0x06) 18:10:17.319 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:10:17.361 SERIAL « 0x010900040020032001ff0f (11 bytes) 18:10:17.362 SERIAL » [ACK] (0x06) 18:10:17.363 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:10:17.365 CNTRLR [Node 032] treating BasicCC Set as a report 18:10:17.366 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:10:17.371 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:10:17.372 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:17.374 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:10:17.375 SERIAL » [ACK] (0x06) 18:10:17.376 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:10:17.502 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:10:17.503 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:17.504 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:10:17.505 SERIAL » [ACK] (0x06) 18:10:17.506 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:10:17.621 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:10:17.622 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:17.623 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:10:17.624 SERIAL » [ACK] (0x06) 18:10:17.625 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:10:17.678 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:10:17.679 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:17.680 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:10:17.681 SERIAL » [ACK] (0x06) 18:10:17.683 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:10:17.725 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:10:17.726 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:17.727 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:10:17.727 SERIAL » [ACK] (0x06) 18:10:17.729 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:10:17.763 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:10:17.764 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:17.765 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:10:17.765 SERIAL » [ACK] (0x06) 18:10:17.767 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:10:17.827 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:10:17.828 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:17.828 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:10:17.829 SERIAL » [ACK] (0x06) 18:10:17.831 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:10:17.942 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:10:17.943 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:17.944 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:10:17.945 SERIAL » [ACK] (0x06) 18:10:17.946 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:10:18.000 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:10:18.001 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:18.002 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:10:18.003 SERIAL » [ACK] (0x06) 18:10:18.005 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:10:34.703 SERIAL « 0x01090004000803300300ca (11 bytes) 18:10:34.704 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:34.704 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:10:34.705 SERIAL » [ACK] (0x06) 18:10:34.706 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:10:34.757 SERIAL « 0x01090004000803200100d8 (11 bytes) 18:10:34.758 SERIAL » [ACK] (0x06) 18:10:34.759 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:10:34.761 CNTRLR [Node 008] treating BasicCC Set as a report 18:10:34.761 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:10:35.843 SERIAL « 0x01080004001e0284076c (10 bytes) 18:10:35.844 SERIAL » [ACK] (0x06) 18:10:35.845 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 18:10:35.847 CNTRLR « [Node 030] received wakeup notification 18:10:35.848 CNTRLR [Node 030] The node is now awake. 18:10:36.849 CNTRLR » [Node 030] Sending node back to sleep... 18:10:36.858 SERIAL » 0x010900131e028408254c1c (11 bytes) 18:10:36.859 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 76 └─[WakeUpCCNoMoreInformation] 18:10:36.861 SERIAL « [ACK] (0x06) 18:10:36.868 SERIAL « 0x0104011301e8 (6 bytes) 18:10:36.868 SERIAL » [ACK] (0x06) 18:10:36.869 DRIVER « [RES] [SendData] was sent: true 18:10:36.885 SERIAL « 0x010700134c000002a5 (9 bytes) 18:10:36.886 SERIAL » [ACK] (0x06) 18:10:36.887 DRIVER « [REQ] [SendData] callback id: 76 transmit status: OK 18:10:36.896 CNTRLR [Node 030] The node is now asleep. 18:10:37.799 SERIAL « 0x01090004001e03300300dc (11 bytes) 18:10:37.800 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:37.801 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:10:37.801 SERIAL » [ACK] (0x06) 18:10:37.802 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:10:37.854 SERIAL « 0x01090004001e03200100ce (11 bytes) 18:10:37.854 SERIAL » [ACK] (0x06) 18:10:37.855 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:10:37.857 CNTRLR [Node 030] treating BasicCC Set as a report 18:10:37.858 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:10:40.205 SERIAL « 0x01090004001e033003ff23 (11 bytes) 18:10:40.207 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:40.208 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:10:40.209 SERIAL » [ACK] (0x06) 18:10:40.210 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:10:40.260 SERIAL « 0x01090004001e032001ff31 (11 bytes) 18:10:40.261 SERIAL » [ACK] (0x06) 18:10:40.262 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:10:40.264 CNTRLR [Node 030] treating BasicCC Set as a report 18:10:40.265 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:10:43.218 SERIAL « 0x010900040007033003ff3a (11 bytes) 18:10:43.219 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:10:43.220 CNTRLR [Node 007] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:10:43.221 SERIAL » [ACK] (0x06) 18:10:43.223 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:10:43.461 SERIAL « 0x0110000400070a7105000000ff0708000062 (18 bytes) 18:10:43.463 SERIAL » [ACK] (0x06) 18:10:43.464 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 18:10:43.467 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 18:11:00.989 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:11:00.990 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:11:00.996 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:11:00.997 SERIAL » [ACK] (0x06) 18:11:00.999 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:11:01.021 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:11:01.023 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:11:01.024 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:11:01.025 SERIAL » [ACK] (0x06) 18:11:01.026 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:11:01.053 SERIAL « 0x01090004002003200100f0 (11 bytes) 18:11:01.053 SERIAL » [ACK] (0x06) 18:11:01.054 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:11:01.056 CNTRLR [Node 032] treating BasicCC Set as a report 18:11:01.057 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:11:01.059 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:11:01.060 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:11:01.060 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:11:01.061 SERIAL » [ACK] (0x06) 18:11:01.063 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:11:01.127 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:11:01.128 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:11:01.129 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:11:01.130 SERIAL » [ACK] (0x06) 18:11:01.131 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:11:01.192 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:11:01.193 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:11:01.194 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:11:01.195 SERIAL » [ACK] (0x06) 18:11:01.196 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:11:01.265 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:11:01.266 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:11:01.267 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:11:01.268 SERIAL » [ACK] (0x06) 18:11:01.269 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:11:01.365 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:11:01.366 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:11:01.367 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:11:01.368 SERIAL » [ACK] (0x06) 18:11:01.369 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:11:01.415 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:11:01.416 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:11:01.417 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:11:01.418 SERIAL » [ACK] (0x06) 18:11:01.419 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:11:01.478 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:11:01.479 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:11:01.480 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:11:01.480 SERIAL » [ACK] (0x06) 18:11:01.482 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:11:01.660 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:11:01.661 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:11:01.662 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:11:01.663 SERIAL » [ACK] (0x06) 18:11:01.664 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:11:07.089 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 18:11:07.090 SERIAL » [ACK] (0x06) 18:11:07.092 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  18:11:07.096 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 18:11:07.680 SERIAL « 0x0108000400060298402f (10 bytes) 18:11:07.681 SERIAL » [ACK] (0x06) 18:11:07.682 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 18:11:07.687 SERIAL » 0x01110013060a988045edfff539a6eec6054db4 (19 bytes) 18:11:07.688 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 77 └─[SecurityCCNonceReport] nonce: 0x45edfff539a6eec6 18:11:07.689 SERIAL « [ACK] (0x06) 18:11:07.695 SERIAL « 0x0104011301e8 (6 bytes) 18:11:07.695 SERIAL » [ACK] (0x06) 18:11:07.696 DRIVER « [RES] [SendData] was sent: true 18:11:07.812 SERIAL « 0x010700134d00000caa (9 bytes) 18:11:07.812 SERIAL » [ACK] (0x06) 18:11:07.812 DRIVER « [REQ] [SendData] callback id: 77 transmit status: OK 18:11:07.978 SERIAL « 0x0128000400062298811dfe0e3deed5b5431c54ae572ce6b57bf9319e084cde344 (42 bytes) 57e41c292c65e75750c 18:11:07.980 SERIAL » [ACK] (0x06) 18:11:07.984 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0x00) event parameters:  18:11:07.987 CNTRLR [Node 006] [+] [Notification] Power Management[Battery level stat [Endpoint 1] us]: 0 18:11:08.135 SERIAL « 0x0108000400060298402f (10 bytes) 18:11:08.136 SERIAL » [ACK] (0x06) 18:11:08.137 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 18:11:08.148 SERIAL » 0x01110013060a988040b6a3a9c4a6a554054ecd (19 bytes) 18:11:08.149 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 78 └─[SecurityCCNonceReport] nonce: 0x40b6a3a9c4a6a554 18:11:08.151 SERIAL « [ACK] (0x06) 18:11:08.158 SERIAL « 0x0104011301e8 (6 bytes) 18:11:08.158 SERIAL » [ACK] (0x06) 18:11:08.159 DRIVER « [RES] [SendData] was sent: true 18:11:08.281 SERIAL « 0x010700134e00000da8 (9 bytes) 18:11:08.281 SERIAL » [ACK] (0x06) 18:11:08.282 DRIVER « [REQ] [SendData] callback id: 78 transmit status: OK 18:11:08.377 SERIAL « 0x012700040006219881009f2d53a804312d5ca224ad02c0a845970523c0038a40f (41 bytes) 28a57ed094365f749 18:11:08.378 SERIAL » [ACK] (0x06) 18:11:08.380 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[NotificationCCReport] notification type: Power Management notification status: 255 notification event: Unknown (0x0c) 18:11:08.381 CNTRLR [Node 006] [+] [Notification] Power Management[Battery load statu [Endpoint 1] s]: 12 18:11:10.687 SERIAL « 0x01090004001e03300300dc (11 bytes) 18:11:10.688 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:11:10.689 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:11:10.690 SERIAL » [ACK] (0x06) 18:11:10.691 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:11:10.742 SERIAL « 0x01090004001e03200100ce (11 bytes) 18:11:10.743 SERIAL » [ACK] (0x06) 18:11:10.744 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:11:10.746 CNTRLR [Node 030] treating BasicCC Set as a report 18:11:10.746 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:11:12.397 SERIAL « 0x01090004000703300300c5 (11 bytes) 18:11:12.398 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:11:12.398 CNTRLR [Node 007] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:11:12.399 SERIAL » [ACK] (0x06) 18:11:12.400 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:11:12.641 SERIAL « 0x0110000400070a7105000000ff070000006a (18 bytes) 18:11:12.642 SERIAL » [ACK] (0x06) 18:11:12.643 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) 18:11:12.669 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 18:11:14.297 SERIAL « 0x010900040007033003ff3a (11 bytes) 18:11:14.298 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:11:14.299 CNTRLR [Node 007] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:11:14.300 SERIAL » [ACK] (0x06) 18:11:14.302 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:11:14.541 SERIAL « 0x0110000400070a7105000000ff0708000062 (18 bytes) 18:11:14.542 SERIAL » [ACK] (0x06) 18:11:14.543 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 18:11:14.546 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 18:11:18.145 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 18:11:18.146 SERIAL » [ACK] (0x06) 18:11:18.148 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 18:11:18.150 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 18:11:18.239 SERIAL « 0x01090004001e033003ff23 (11 bytes) 18:11:18.240 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:11:18.240 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:11:18.241 SERIAL » [ACK] (0x06) 18:11:18.242 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:11:18.293 SERIAL « 0x01090004001e032001ff31 (11 bytes) 18:11:18.294 SERIAL » [ACK] (0x06) 18:11:18.294 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:11:18.296 CNTRLR [Node 030] treating BasicCC Set as a report 18:11:18.296 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:11:32.316 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:11:32.317 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:11:32.317 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:11:32.325 SERIAL » [ACK] (0x06) 18:11:32.327 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:11:32.385 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:11:32.386 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:11:32.387 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:11:32.388 SERIAL » [ACK] (0x06) 18:11:32.390 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:11:32.474 SERIAL « 0x010900040020032001ff0f (11 bytes) 18:11:32.475 SERIAL » [ACK] (0x06) 18:11:32.476 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:11:32.478 CNTRLR [Node 032] treating BasicCC Set as a report 18:11:32.478 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:11:32.499 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:11:32.500 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:11:32.500 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:11:32.501 SERIAL » [ACK] (0x06) 18:11:32.502 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:11:32.529 SERIAL « 0x010900041000033003df0d (11 bytes) 18:11:32.530 DRIVER Dropping message because the driver is not ready to handle it yet. 18:11:32.530 SERIAL » [ACK] (0x06) 18:11:32.617 SERIAL « 0x010900041000033003df0d (11 bytes) 18:11:32.618 DRIVER Dropping message because the driver is not ready to handle it yet. 18:11:32.618 SERIAL » [ACK] (0x06) 18:11:32.625 SERIAL « 0x010900041000033003df0d (11 bytes) 18:11:32.626 DRIVER Dropping message because the driver is not ready to handle it yet. 18:11:32.626 SERIAL » [ACK] (0x06) 18:11:32.682 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:11:32.683 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:11:32.684 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:11:32.685 SERIAL » [ACK] (0x06) 18:11:32.686 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:11:32.731 SERIAL « 0x010900041000033003df0d (11 bytes) 18:11:32.732 DRIVER Dropping message because the driver is not ready to handle it yet. 18:11:32.732 SERIAL » [ACK] (0x06) 18:11:32.784 SERIAL « 0x010900041000033003df0d (11 bytes) 18:11:32.785 DRIVER Dropping message because the driver is not ready to handle it yet. 18:11:32.786 SERIAL » [ACK] (0x06) 18:11:32.834 SERIAL « 0x010900041000033003df0d (11 bytes) 18:11:32.835 DRIVER Dropping message because the driver is not ready to handle it yet. 18:11:32.835 SERIAL » [ACK] (0x06) 18:11:32.862 SERIAL « 0x010900041000033003df0d (11 bytes) 18:11:32.863 DRIVER Dropping message because the driver is not ready to handle it yet. 18:11:32.863 SERIAL » [ACK] (0x06) 18:11:32.957 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:11:32.959 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:11:32.960 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:11:32.960 SERIAL » [ACK] (0x06) 18:11:32.962 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:11:33.044 SERIAL « 0x010900041000033003df0d (11 bytes) 18:11:33.045 DRIVER Dropping message because the driver is not ready to handle it yet. 18:11:33.045 SERIAL » [ACK] (0x06) 18:11:33.055 SERIAL « 0x010900041020033003ff0d (11 bytes) 18:11:33.057 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:11:33.057 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:11:33.058 SERIAL » [ACK] (0x06) 18:11:33.060 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:11:33.065 SERIAL « 0x010900041000033003df0d (11 bytes) 18:11:33.066 DRIVER Dropping message because the driver is not ready to handle it yet. 18:11:33.066 SERIAL » [ACK] (0x06) 18:11:33.106 SERIAL « 0x010900041000033003df0d (11 bytes) 18:11:33.107 DRIVER Dropping message because the driver is not ready to handle it yet. 18:11:33.107 SERIAL » [ACK] (0x06) 18:11:35.378 SERIAL « 0x01090004000703300300c5 (11 bytes) 18:11:35.379 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:11:35.380 CNTRLR [Node 007] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:11:35.381 SERIAL » [ACK] (0x06) 18:11:35.383 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:11:35.621 SERIAL « 0x0110000400070a7105000000ff070000006a (18 bytes) 18:11:35.622 SERIAL » [ACK] (0x06) 18:11:35.623 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) 18:11:35.658 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 18:11:44.049 SERIAL » 0x011000131c09600d00014301010114254fb9 (18 bytes) 18:11:44.050 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 79 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCSet] setpoint type: Heating value: 20 °C 18:11:44.053 SERIAL « [ACK] (0x06) 18:11:44.060 SERIAL « 0x0104011301e8 (6 bytes) 18:11:44.060 SERIAL » [ACK] (0x06) 18:11:44.061 DRIVER « [RES] [SendData] was sent: true 18:11:45.475 SERIAL « 0x010700134f00008e2a (9 bytes) 18:11:45.476 SERIAL » [ACK] (0x06) 18:11:45.476 DRIVER « [REQ] [SendData] callback id: 79 transmit status: OK 18:11:45.482 SERIAL » 0x010e00131c07600d00014302012550a0 (16 bytes) 18:11:45.482 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 80 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:11:45.484 SERIAL « [ACK] (0x06) 18:11:45.490 SERIAL « 0x0104011301e8 (6 bytes) 18:11:45.491 SERIAL » [ACK] (0x06) 18:11:45.491 DRIVER « [RES] [SendData] was sent: true 18:11:45.550 SERIAL « 0x0107001350000007bc (9 bytes) 18:11:45.551 SERIAL » [ACK] (0x06) 18:11:45.551 DRIVER « [REQ] [SendData] callback id: 80 transmit status: OK 18:11:45.633 SERIAL « 0x010a0004001c0422010102c9 (12 bytes) 18:11:45.634 DRIVER Dropping message because it could not be deserialized: The command class Appli cation Status is not implemented 18:11:45.634 SERIAL » [ACK] (0x06) 18:11:45.837 SERIAL « 0x0110000400120a600d02003105012200a52e (18 bytes) 18:11:45.839 CNTRLR [Node 018] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 18:11:45.842 CNTRLR [Node 018] [~] [Multilevel Sensor] Air temperature: 16.3 => 16.5 [Endpoint 2] 18:11:45.843 SERIAL » [ACK] (0x06) 18:11:45.846 DRIVER « [Node 018] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 16.5 18:11:47.155 CNTRLR [Node 028] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 18:11:47.660 SERIAL » 0x010e00131c07600d00014302012550a0 (16 bytes) 18:11:47.661 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 80 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:11:47.663 SERIAL « [ACK] (0x06) 18:11:47.670 SERIAL « 0x0104011301e8 (6 bytes) 18:11:47.670 SERIAL » [ACK] (0x06) 18:11:47.671 DRIVER « [RES] [SendData] was sent: true 18:11:49.082 SERIAL « 0x010700135000008e35 (9 bytes) 18:11:49.082 SERIAL » [ACK] (0x06) 18:11:49.083 DRIVER « [REQ] [SendData] callback id: 80 transmit status: OK 18:11:49.156 SERIAL « 0x010c0004000306310504220916ff (14 bytes) 18:11:49.156 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:11:49.157 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 113.9 => 232.6 [Endpoint 0] 18:11:49.157 SERIAL » [ACK] (0x06) 18:11:49.158 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 232.6 18:11:50.156 SERIAL « 0x010c000400030631050422031dfe (14 bytes) 18:11:50.157 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:11:50.158 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 232.6 => 79.7 [Endpoint 0] 18:11:50.159 SERIAL » [ACK] (0x06) 18:11:50.161 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 79.7 18:11:50.505 SERIAL « 0x01100004001c0a600d01004303012200c83a (18 bytes) 18:11:50.507 CNTRLR [Node 028] [~] [Thermostat Setpoint] setpoint[1]: 10 => 20 [Endpoint 1] 18:11:50.508 CNTRLR [Node 028] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 18:11:50.508 SERIAL » [ACK] (0x06) 18:11:50.510 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 20 °C 18:11:51.157 SERIAL « 0x010c000400030631050422047b9f (14 bytes) 18:11:51.160 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:11:51.165 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 79.7 => 114.7 [Endpoint 0] 18:11:51.167 SERIAL » [ACK] (0x06) 18:11:51.169 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 114.7 18:11:52.889 SERIAL « 0x01090004001e03200100ce (11 bytes) 18:11:52.889 SERIAL » [ACK] (0x06) 18:11:52.890 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:11:52.892 CNTRLR [Node 030] treating BasicCC Set as a report 18:11:52.893 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:11:57.258 SERIAL » 0x011000131c09600d0001430101010a2551b9 (18 bytes) 18:11:57.260 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 81 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCSet] setpoint type: Heating value: 10 °C 18:11:57.263 SERIAL « [ACK] (0x06) 18:11:57.269 SERIAL « 0x0104011301e8 (6 bytes) 18:11:57.270 SERIAL » [ACK] (0x06) 18:11:57.270 DRIVER « [RES] [SendData] was sent: true 18:11:58.631 SERIAL « 0x010700135100008933 (9 bytes) 18:11:58.632 SERIAL » [ACK] (0x06) 18:11:58.633 DRIVER « [REQ] [SendData] callback id: 81 transmit status: OK 18:11:58.646 SERIAL » 0x010e00131c07600d00014302012552a2 (16 bytes) 18:11:58.647 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 82 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:11:58.649 SERIAL « [ACK] (0x06) 18:11:58.655 SERIAL « 0x0104011301e8 (6 bytes) 18:11:58.656 SERIAL » [ACK] (0x06) 18:11:58.657 DRIVER « [RES] [SendData] was sent: true 18:11:58.714 SERIAL « 0x0107001352000006bf (9 bytes) 18:11:58.715 SERIAL » [ACK] (0x06) 18:11:58.716 DRIVER « [REQ] [SendData] callback id: 82 transmit status: OK 18:11:58.799 SERIAL « 0x010a0004001c0422010102c9 (12 bytes) 18:11:58.800 DRIVER Dropping message because it could not be deserialized: The command class Appli cation Status is not implemented 18:11:58.800 SERIAL » [ACK] (0x06) 18:12:00.319 CNTRLR [Node 028] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 18:12:00.826 SERIAL » 0x010e00131c07600d00014302012552a2 (16 bytes) 18:12:00.827 DRIVER » [Node 028] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 82 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:12:00.829 SERIAL « [ACK] (0x06) 18:12:00.836 SERIAL « 0x0104011301e8 (6 bytes) 18:12:00.836 SERIAL » [ACK] (0x06) 18:12:00.838 DRIVER « [RES] [SendData] was sent: true 18:12:00.893 SERIAL « 0x0107001352000006bf (9 bytes) 18:12:00.894 SERIAL » [ACK] (0x06) 18:12:00.895 DRIVER « [REQ] [SendData] callback id: 82 transmit status: OK 18:12:01.002 SERIAL « 0x01100004001c0a600d010043030122006496 (18 bytes) 18:12:01.004 CNTRLR [Node 028] [~] [Thermostat Setpoint] setpoint[1]: 20 => 10 [Endpoint 1] 18:12:01.005 CNTRLR [Node 028] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 18:12:01.005 SERIAL » [ACK] (0x06) 18:12:01.007 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 18:12:01.157 SERIAL « 0x010c0004000306310504220a1ef4 (14 bytes) 18:12:01.158 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:12:01.159 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 114.7 => 259 [Endpoint 0] 18:12:01.160 SERIAL » [ACK] (0x06) 18:12:01.162 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 259 18:12:02.157 SERIAL « 0x010c00040003063105042203a142 (14 bytes) 18:12:02.158 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:12:02.158 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 259 => 92.9 [Endpoint 0] 18:12:02.159 SERIAL » [ACK] (0x06) 18:12:02.160 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 92.9 18:12:10.077 SERIAL » 0x011000131d09600d000143010101142553a4 (18 bytes) 18:12:10.078 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 83 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCSet] setpoint type: Heating value: 20 °C 18:12:10.081 SERIAL « [ACK] (0x06) 18:12:10.087 SERIAL « 0x0104011301e8 (6 bytes) 18:12:10.088 SERIAL » [ACK] (0x06) 18:12:10.088 DRIVER « [RES] [SendData] was sent: true 18:12:11.578 SERIAL « 0x01070013530000962e (9 bytes) 18:12:11.579 SERIAL » [ACK] (0x06) 18:12:11.580 DRIVER « [REQ] [SendData] callback id: 83 transmit status: OK 18:12:11.598 SERIAL » 0x010e00131d07600d00014302012554a5 (16 bytes) 18:12:11.599 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 84 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:12:11.602 SERIAL « [ACK] (0x06) 18:12:11.608 SERIAL « 0x0104011301e8 (6 bytes) 18:12:11.609 SERIAL » [ACK] (0x06) 18:12:11.610 DRIVER « [RES] [SendData] was sent: true 18:12:17.146 SERIAL « 0x010700135400022a97 (9 bytes) 18:12:17.146 SERIAL » [ACK] (0x06) 18:12:17.147 DRIVER « [REQ] [SendData] callback id: 84 transmit status: OK 18:12:17.297 SERIAL « 0x01100004001d0a600d01004303012200c83b (18 bytes) 18:12:17.298 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpoint[1]: 10 => 20 [Endpoint 1] 18:12:17.299 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 18:12:17.299 SERIAL » [ACK] (0x06) 18:12:17.301 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 20 °C 18:12:19.016 SERIAL » 0x011000131d09600d0001430101010a2555bc (18 bytes) 18:12:19.017 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 85 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCSet] setpoint type: Heating value: 10 °C 18:12:19.018 SERIAL « [ACK] (0x06) 18:12:19.025 SERIAL « 0x0104011301e8 (6 bytes) 18:12:19.025 SERIAL » [ACK] (0x06) 18:12:19.026 DRIVER « [RES] [SendData] was sent: true 18:12:20.440 SERIAL « 0x010700135500008e30 (9 bytes) 18:12:20.441 SERIAL » [ACK] (0x06) 18:12:20.442 DRIVER « [REQ] [SendData] callback id: 85 transmit status: OK 18:12:20.457 SERIAL » 0x010e00131d07600d00014302012556a7 (16 bytes) 18:12:20.458 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 86 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:12:20.460 SERIAL « [ACK] (0x06) 18:12:20.466 SERIAL « 0x0104011301e8 (6 bytes) 18:12:20.467 SERIAL » [ACK] (0x06) 18:12:20.468 DRIVER « [RES] [SendData] was sent: true 18:12:20.526 SERIAL « 0x0107001356000006bb (9 bytes) 18:12:20.526 SERIAL » [ACK] (0x06) 18:12:20.527 DRIVER « [REQ] [SendData] callback id: 86 transmit status: OK 18:12:20.603 SERIAL « 0x010a0004001d0422010102c8 (12 bytes) 18:12:20.604 DRIVER Dropping message because it could not be deserialized: The command class Appli cation Status is not implemented 18:12:20.605 SERIAL » [ACK] (0x06) 18:12:22.132 CNTRLR [Node 029] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 18:12:22.635 SERIAL » 0x010e00131d07600d00014302012556a7 (16 bytes) 18:12:22.635 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 86 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ThermostatSetpointCCGet] setpoint type: Heating 18:12:22.637 SERIAL « [ACK] (0x06) 18:12:22.643 SERIAL « 0x0104011301e8 (6 bytes) 18:12:22.644 SERIAL » [ACK] (0x06) 18:12:22.644 DRIVER « [RES] [SendData] was sent: true 18:12:22.701 SERIAL « 0x0107001356000006bb (9 bytes) 18:12:22.701 SERIAL » [ACK] (0x06) 18:12:22.702 DRIVER « [REQ] [SendData] callback id: 86 transmit status: OK 18:12:22.811 SERIAL « 0x01100004001d0a600d010043030122006497 (18 bytes) 18:12:22.811 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpoint[1]: 20 => 10 [Endpoint 1] 18:12:22.812 CNTRLR [Node 029] [~] [Thermostat Setpoint] setpointScale[1]: [Endpoint 1] [internal] 0 => 0 18:12:22.812 SERIAL » [ACK] (0x06) 18:12:22.813 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ThermostatSetpointCCReport] setpoint type: Heating value: 10 °C 18:12:29.405 SERIAL « 0x0110000400020a7105000000ff0700010866 (18 bytes) 18:12:29.406 SERIAL » [ACK] (0x06) 18:12:29.407 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) event parameters:  18:12:29.416 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 18:12:30.222 SERIAL « 0x010f00040002097105000000ff0708007b (17 bytes) 18:12:30.223 SERIAL » [ACK] (0x06) 18:12:30.224 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 18:12:30.227 CNTRLR [Node 002] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 18:12:33.847 SERIAL « 0x01090004001e033003ff23 (11 bytes) 18:12:33.849 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:12:33.850 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:12:33.851 SERIAL » [ACK] (0x06) 18:12:33.852 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:12:33.902 SERIAL « 0x01090004001e032001ff31 (11 bytes) 18:12:33.903 SERIAL » [ACK] (0x06) 18:12:33.904 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:12:33.907 CNTRLR [Node 030] treating BasicCC Set as a report 18:12:33.907 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:12:39.217 SERIAL « 0x010900040007033003ff3a (11 bytes) 18:12:39.218 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:12:39.219 CNTRLR [Node 007] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:12:39.219 SERIAL » [ACK] (0x06) 18:12:39.221 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:12:39.460 SERIAL « 0x0110000400070a7105000000ff0708000062 (18 bytes) 18:12:39.461 SERIAL » [ACK] (0x06) 18:12:39.463 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 18:12:39.465 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 18:12:53.847 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:12:53.849 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:12:53.850 CNTRLR [Node 032] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:12:53.850 SERIAL » [ACK] (0x06) 18:12:53.852 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:12:53.935 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:12:53.936 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:12:53.937 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:12:53.938 SERIAL » [ACK] (0x06) 18:12:53.939 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:12:53.984 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:12:53.986 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:12:53.987 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:12:53.987 SERIAL » [ACK] (0x06) 18:12:53.988 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:12:54.099 SERIAL « 0x01090004002003200100f0 (11 bytes) 18:12:54.100 SERIAL » [ACK] (0x06) 18:12:54.100 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:12:54.102 CNTRLR [Node 032] treating BasicCC Set as a report 18:12:54.103 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:12:54.135 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:12:54.136 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:12:54.137 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:12:54.138 SERIAL » [ACK] (0x06) 18:12:54.139 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:12:54.152 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:12:54.153 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:12:54.154 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:12:54.155 SERIAL » [ACK] (0x06) 18:12:54.156 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:12:54.186 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:12:54.187 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:12:54.188 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:12:54.189 SERIAL » [ACK] (0x06) 18:12:54.190 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:12:54.283 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:12:54.284 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:12:54.284 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:12:54.285 SERIAL » [ACK] (0x06) 18:12:54.286 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:12:54.345 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:12:54.346 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:12:54.346 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:12:54.347 SERIAL » [ACK] (0x06) 18:12:54.347 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:12:54.392 SERIAL « 0x01090004102003300300f2 (11 bytes) 18:12:54.393 CNTRLR [Node 032] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:12:54.394 CNTRLR [Node 032] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:12:54.394 SERIAL » [ACK] (0x06) 18:12:54.395 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:12:54.953 SERIAL « 0x010900040015033003ff28 (11 bytes) 18:12:54.954 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:12:54.955 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:12:54.956 SERIAL » [ACK] (0x06) 18:12:54.957 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:12:55.008 SERIAL « 0x010900040015032001ff3a (11 bytes) 18:12:55.009 SERIAL » [ACK] (0x06) 18:12:55.010 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:12:55.013 CNTRLR [Node 021] treating BasicCC Set as a report 18:12:55.014 CNTRLR [Node 021] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:12:57.377 SERIAL « 0x01090004000703300300c5 (11 bytes) 18:12:57.378 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:12:57.378 CNTRLR [Node 007] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:12:57.378 SERIAL » [ACK] (0x06) 18:12:57.379 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:12:57.620 SERIAL « 0x0110000400070a7105000000ff070000006a (18 bytes) 18:12:57.621 SERIAL » [ACK] (0x06) 18:12:57.621 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) 18:12:57.636 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 18:13:01.163 SERIAL « 0x010c000400030631050422039477 (14 bytes) 18:13:01.164 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:13:01.165 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 92.9 => 91.6 [Endpoint 0] 18:13:01.166 SERIAL » [ACK] (0x06) 18:13:01.168 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 91.6 18:13:02.163 SERIAL « 0x010c00040003063105042204688c (14 bytes) 18:13:02.164 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:13:02.165 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 91.6 => 112.8 [Endpoint 0] 18:13:02.166 SERIAL » [ACK] (0x06) 18:13:02.168 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 112.8 18:13:06.725 SERIAL « 0x01100004001c0a600d02003105012200bc39 (18 bytes) 18:13:06.726 CNTRLR [Node 028] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 18:13:06.727 CNTRLR [Node 028] [~] [Multilevel Sensor] Air temperature: 18.5 => 18.8 [Endpoint 2] 18:13:06.728 SERIAL » [ACK] (0x06) 18:13:06.729 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 18.8 18:13:21.207 SERIAL « 0x010c00040002063105030a0015db (14 bytes) 18:13:21.208 CNTRLR [Node 002] [Multilevel Sensor] Illuminance: metadata updated [Endpoint 0] 18:13:21.208 CNTRLR [Node 002] [~] [Multilevel Sensor] Illuminance: 20 => 21 [Endpoint 0] 18:13:21.208 SERIAL » [ACK] (0x06) 18:13:21.209 DRIVER « [Node 002] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Illuminance scale: Lux value: 21 18:13:22.883 SERIAL » 0x010a001314032601002557a4 (12 bytes) 18:13:22.884 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 87 └─[MultilevelSwitchCCSet] target value: 0 18:13:22.888 SERIAL « [ACK] (0x06) 18:13:22.894 SERIAL « 0x0104011301e8 (6 bytes) 18:13:22.895 SERIAL » [ACK] (0x06) 18:13:22.895 DRIVER « [RES] [SendData] was sent: true 18:13:22.991 SERIAL « 0x010700135700000ab6 (9 bytes) 18:13:22.992 SERIAL » [ACK] (0x06) 18:13:22.993 DRIVER « [REQ] [SendData] callback id: 87 transmit status: OK 18:13:23.000 SERIAL » 0x010a001313032601002558ac (12 bytes) 18:13:23.000 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 88 └─[MultilevelSwitchCCSet] target value: 0 18:13:23.005 SERIAL « [ACK] (0x06) 18:13:23.009 SERIAL « 0x0104011301e8 (6 bytes) 18:13:23.009 SERIAL » [ACK] (0x06) 18:13:23.010 DRIVER « [RES] [SendData] was sent: true 18:13:23.026 SERIAL « 0x0107001358000003b0 (9 bytes) 18:13:23.027 SERIAL » [ACK] (0x06) 18:13:23.027 DRIVER « [REQ] [SendData] callback id: 88 transmit status: OK 18:13:23.038 SERIAL » 0x01090013140226022559ab (11 bytes) 18:13:23.038 DRIVER » [Node 020] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 89 └─[MultilevelSwitchCCGet] 18:13:23.043 SERIAL « [ACK] (0x06) 18:13:23.047 SERIAL « 0x0104011301e8 (6 bytes) 18:13:23.047 SERIAL » [ACK] (0x06) 18:13:23.048 DRIVER « [RES] [SendData] was sent: true 18:13:23.142 SERIAL « 0x010700135900000ab8 (9 bytes) 18:13:23.142 SERIAL » [ACK] (0x06) 18:13:23.143 DRIVER « [REQ] [SendData] callback id: 89 transmit status: OK 18:13:23.298 SERIAL « 0x01090004001403260327e7 (11 bytes) 18:13:23.300 CNTRLR [Node 020] [~] [Multilevel Switch] currentValue: 39 => 39 [Endpoint 0] 18:13:23.301 SERIAL » [ACK] (0x06) 18:13:23.302 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 39 18:13:23.308 SERIAL » 0x0109001313022602255aaf (11 bytes) 18:13:23.308 DRIVER » [Node 019] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 90 └─[MultilevelSwitchCCGet] 18:13:23.311 SERIAL « [ACK] (0x06) 18:13:23.317 SERIAL « 0x0104011301e8 (6 bytes) 18:13:23.318 SERIAL » [ACK] (0x06) 18:13:23.319 DRIVER « [RES] [SendData] was sent: true 18:13:23.391 SERIAL « 0x010700135a000008b9 (9 bytes) 18:13:23.392 SERIAL » [ACK] (0x06) 18:13:23.393 DRIVER « [REQ] [SendData] callback id: 90 transmit status: OK 18:13:23.402 SERIAL « 0x01090004001303260327e0 (11 bytes) 18:13:23.403 CNTRLR [Node 019] [~] [Multilevel Switch] currentValue: 39 => 39 [Endpoint 0] 18:13:23.403 SERIAL » [ACK] (0x06) 18:13:23.404 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 39 18:13:24.089 SERIAL « 0x010c00040014063105042205ca38 (14 bytes) 18:13:24.090 CNTRLR [Node 020] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:13:24.091 CNTRLR [Node 020] [~] [Multilevel Sensor] Power: 0 => 148.2 [Endpoint 0] 18:13:24.092 SERIAL » [ACK] (0x06) 18:13:24.093 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 148.2 18:13:24.143 SERIAL « 0x010c0004001306310504220536c3 (14 bytes) 18:13:24.144 CNTRLR [Node 019] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:13:24.146 CNTRLR [Node 019] [~] [Multilevel Sensor] Power: 0 => 133.4 [Endpoint 0] 18:13:24.146 SERIAL » [ACK] (0x06) 18:13:24.148 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 133.4 18:13:25.779 SERIAL « 0x01090004001b03300300d9 (11 bytes) 18:13:25.781 CNTRLR [Node 027] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:13:25.782 CNTRLR [Node 027] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:13:25.783 SERIAL » [ACK] (0x06) 18:13:25.784 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:13:25.834 SERIAL « 0x01090004001b03200100cb (11 bytes) 18:13:25.835 SERIAL » [ACK] (0x06) 18:13:25.836 DRIVER « [Node 027] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:13:25.837 CNTRLR [Node 027] treating BasicCC Set as a report 18:13:25.838 CNTRLR [Node 027] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:13:29.295 SERIAL « 0x0108000400060298402f (10 bytes) 18:13:29.296 SERIAL » [ACK] (0x06) 18:13:29.297 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 18:13:29.310 SERIAL » 0x01110013060a988058893bf8bda94d08055bf4 (19 bytes) 18:13:29.311 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 91 └─[SecurityCCNonceReport] nonce: 0x58893bf8bda94d08 18:13:29.314 SERIAL « [ACK] (0x06) 18:13:29.320 SERIAL « 0x0104011301e8 (6 bytes) 18:13:29.320 SERIAL » [ACK] (0x06) 18:13:29.321 DRIVER « [RES] [SendData] was sent: true 18:13:29.421 SERIAL « 0x010700135b00000aba (9 bytes) 18:13:29.422 SERIAL » [ACK] (0x06) 18:13:29.422 DRIVER « [REQ] [SendData] callback id: 91 transmit status: OK 18:13:29.574 SERIAL « 0x0124000400061e9881a7b7066d9c76cc33622d76c1729972ec35e91f58bad3ed7 (38 bytes) deebd9d56c7 18:13:29.576 SERIAL » [ACK] (0x06) 18:13:29.578 CNTRLR [Node 006] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 18:13:29.579 CNTRLR [Node 006] [~] [Multilevel Sensor] Air temperature: 18.9 => 23.2 [Endpoint 2] 18:13:29.580 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 23.2 18:13:29.691 SERIAL « 0x01100004001d0a600d02003105012200b337 (18 bytes) 18:13:29.692 CNTRLR [Node 029] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 18:13:29.693 CNTRLR [Node 029] [~] [Multilevel Sensor] Air temperature: 17.6 => 17.9 [Endpoint 2] 18:13:29.694 SERIAL » [ACK] (0x06) 18:13:29.696 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 17.9 18:13:29.819 SERIAL « 0x0108000400060298402f (10 bytes) 18:13:29.820 SERIAL » [ACK] (0x06) 18:13:29.821 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCNonceGet] 18:13:29.831 SERIAL » 0x01110013060a988024833bb81985ff13055ce4 (19 bytes) 18:13:29.831 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x05 │ callback id: 92 └─[SecurityCCNonceReport] nonce: 0x24833bb81985ff13 18:13:29.833 SERIAL « [ACK] (0x06) 18:13:29.839 SERIAL « 0x0104011301e8 (6 bytes) 18:13:29.840 SERIAL » [ACK] (0x06) 18:13:29.841 DRIVER « [RES] [SendData] was sent: true 18:13:29.960 SERIAL « 0x010700135c00000dba (9 bytes) 18:13:29.961 SERIAL » [ACK] (0x06) 18:13:29.962 DRIVER « [REQ] [SendData] callback id: 92 transmit status: OK 18:13:30.055 SERIAL « 0x0124000400061e9881974df395a3d5cbe4d1d0826b64b7a2309d01a3240e1115b (38 bytes) f40cb81d3e5 18:13:30.056 SERIAL » [ACK] (0x06) 18:13:30.057 CNTRLR [Node 006] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 18:13:30.058 CNTRLR [Node 006] [~] [Multilevel Sensor] Air temperature: 23.2 => 23.2 [Endpoint 2] 18:13:30.058 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[SecurityCCCommandEncapsulation] │ sequenced: false └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 23.2 18:13:30.189 SERIAL « 0x010c0004001406310504220000f7 (14 bytes) 18:13:30.189 CNTRLR [Node 020] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:13:30.190 CNTRLR [Node 020] [~] [Multilevel Sensor] Power: 148.2 => 0 [Endpoint 0] 18:13:30.190 SERIAL » [ACK] (0x06) 18:13:30.191 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 18:13:30.225 SERIAL « 0x01090004001e03300300dc (11 bytes) 18:13:30.226 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:13:30.227 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:13:30.228 SERIAL » [ACK] (0x06) 18:13:30.229 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:13:30.280 SERIAL « 0x01090004001e03200100ce (11 bytes) 18:13:30.280 SERIAL » [ACK] (0x06) 18:13:30.281 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:13:30.282 CNTRLR [Node 030] treating BasicCC Set as a report 18:13:30.282 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:13:30.397 SERIAL « 0x010c0004001306310504220000f0 (14 bytes) 18:13:30.397 CNTRLR [Node 019] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:13:30.398 CNTRLR [Node 019] [~] [Multilevel Sensor] Power: 133.4 => 0 [Endpoint 0] 18:13:30.398 SERIAL » [ACK] (0x06) 18:13:30.399 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 18:13:31.245 SERIAL « 0x01090004001403260300c0 (11 bytes) 18:13:31.246 CNTRLR [Node 020] [~] [Multilevel Switch] currentValue: 39 => 0 [Endpoint 0] 18:13:31.247 SERIAL » [ACK] (0x06) 18:13:31.249 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 0 18:13:31.263 SERIAL « 0x010c0004001406310504220000f7 (14 bytes) 18:13:31.265 CNTRLR [Node 020] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:13:31.266 CNTRLR [Node 020] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 18:13:31.268 SERIAL » [ACK] (0x06) 18:13:31.270 DRIVER « [Node 020] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 18:13:31.514 SERIAL « 0x01090004001303260300c7 (11 bytes) 18:13:31.515 CNTRLR [Node 019] [~] [Multilevel Switch] currentValue: 39 => 0 [Endpoint 0] 18:13:31.516 SERIAL » [ACK] (0x06) 18:13:31.518 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 0 18:13:31.533 SERIAL « 0x010c0004001306310504220000f0 (14 bytes) 18:13:31.535 CNTRLR [Node 019] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:13:31.536 CNTRLR [Node 019] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 18:13:31.537 SERIAL » [ACK] (0x06) 18:13:31.539 DRIVER « [Node 019] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 18:13:36.352 SERIAL » 0x010a00131003260100255daa (12 bytes) 18:13:36.354 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 93 └─[MultilevelSwitchCCSet] target value: 0 18:13:36.355 SERIAL « [ACK] (0x06) 18:13:36.362 SERIAL « 0x0104011301e8 (6 bytes) 18:13:36.362 SERIAL » [ACK] (0x06) 18:13:36.363 DRIVER « [RES] [SendData] was sent: true 18:13:36.504 SERIAL « 0x010700135d00000eb8 (9 bytes) 18:13:36.505 SERIAL » [ACK] (0x06) 18:13:36.505 DRIVER « [REQ] [SendData] callback id: 93 transmit status: OK 18:13:36.516 SERIAL » 0x0109001310022602255ea8 (11 bytes) 18:13:36.516 DRIVER » [Node 016] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 94 └─[MultilevelSwitchCCGet] 18:13:36.518 SERIAL « [ACK] (0x06) 18:13:36.524 SERIAL « 0x0104011301e8 (6 bytes) 18:13:36.525 SERIAL » [ACK] (0x06) 18:13:36.526 DRIVER « [RES] [SendData] was sent: true 18:13:36.563 SERIAL « 0x010700135e000004b1 (9 bytes) 18:13:36.563 SERIAL » [ACK] (0x06) 18:13:36.565 DRIVER « [REQ] [SendData] callback id: 94 transmit status: OK 18:13:36.609 SERIAL « 0x01090004001003260327e3 (11 bytes) 18:13:36.611 CNTRLR [Node 016] [~] [Multilevel Switch] currentValue: 39 => 39 [Endpoint 0] 18:13:36.612 SERIAL » [ACK] (0x06) 18:13:36.614 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 39 18:13:37.536 SERIAL « 0x010c000400100631050422049265 (14 bytes) 18:13:37.537 CNTRLR [Node 016] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:13:37.537 CNTRLR [Node 016] [~] [Multilevel Sensor] Power: 0 => 117 [Endpoint 0] 18:13:37.538 SERIAL » [ACK] (0x06) 18:13:37.538 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 117 18:13:43.032 SERIAL « 0x01090004001e033003ff23 (11 bytes) 18:13:43.033 CNTRLR [Node 030] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:13:43.033 CNTRLR [Node 030] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:13:43.034 SERIAL » [ACK] (0x06) 18:13:43.035 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:13:43.087 SERIAL « 0x01090004001e032001ff31 (11 bytes) 18:13:43.087 SERIAL » [ACK] (0x06) 18:13:43.088 DRIVER « [Node 030] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:13:43.089 CNTRLR [Node 030] treating BasicCC Set as a report 18:13:43.090 CNTRLR [Node 030] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:13:43.664 SERIAL « 0x010c0004001006310504220000f3 (14 bytes) 18:13:43.665 CNTRLR [Node 016] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:13:43.666 CNTRLR [Node 016] [~] [Multilevel Sensor] Power: 117 => 0 [Endpoint 0] 18:13:43.667 SERIAL » [ACK] (0x06) 18:13:43.669 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 18:13:44.275 SERIAL « 0x010900040007033003ff3a (11 bytes) 18:13:44.276 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:13:44.277 CNTRLR [Node 007] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:13:44.278 SERIAL » [ACK] (0x06) 18:13:44.280 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:13:44.520 SERIAL « 0x0110000400070a7105000000ff0708000062 (18 bytes) 18:13:44.521 SERIAL » [ACK] (0x06) 18:13:44.521 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x08) 18:13:44.523 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 0 => 8 18:13:45.114 SERIAL « 0x01090004001003260300c4 (11 bytes) 18:13:45.115 CNTRLR [Node 016] [~] [Multilevel Switch] currentValue: 39 => 0 [Endpoint 0] 18:13:45.116 SERIAL » [ACK] (0x06) 18:13:45.118 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 0 18:13:45.158 SERIAL « 0x010c0004001006310504220000f3 (14 bytes) 18:13:45.160 CNTRLR [Node 016] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:13:45.161 CNTRLR [Node 016] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 18:13:45.162 SERIAL » [ACK] (0x06) 18:13:45.163 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 18:13:48.111 SERIAL » 0x010a00130c03260100255fb4 (12 bytes) 18:13:48.112 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 95 └─[MultilevelSwitchCCSet] target value: 0 18:13:48.113 SERIAL « [ACK] (0x06) 18:13:48.120 SERIAL « 0x0104011301e8 (6 bytes) 18:13:48.120 SERIAL » [ACK] (0x06) 18:13:48.120 DRIVER « [RES] [SendData] was sent: true 18:13:48.140 SERIAL « 0x010700135f000003b7 (9 bytes) 18:13:48.141 SERIAL » [ACK] (0x06) 18:13:48.142 DRIVER « [REQ] [SendData] callback id: 95 transmit status: OK 18:13:48.154 SERIAL » 0x010900130c02260225608a (11 bytes) 18:13:48.155 DRIVER » [Node 012] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 96 └─[MultilevelSwitchCCGet] 18:13:48.157 SERIAL « [ACK] (0x06) 18:13:48.163 SERIAL « 0x0104011301e8 (6 bytes) 18:13:48.163 SERIAL » [ACK] (0x06) 18:13:48.164 DRIVER « [RES] [SendData] was sent: true 18:13:48.171 SERIAL « 0x010c000400030631050422088f67 (14 bytes) 18:13:48.172 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:13:48.173 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 112.8 => 219.1 [Endpoint 0] 18:13:48.173 SERIAL » [ACK] (0x06) 18:13:48.174 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 219.1 18:13:48.192 SERIAL « 0x010700136000000388 (9 bytes) 18:13:48.192 SERIAL » [ACK] (0x06) 18:13:48.193 DRIVER « [REQ] [SendData] callback id: 96 transmit status: OK 18:13:48.202 SERIAL « 0x01090004000c03260327ff (11 bytes) 18:13:48.203 CNTRLR [Node 012] [~] [Multilevel Switch] currentValue: 39 => 39 [Endpoint 0] 18:13:48.206 SERIAL » [ACK] (0x06) 18:13:48.207 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 39 18:13:49.167 SERIAL « 0x010c0004000306310504220436d2 (14 bytes) 18:13:49.169 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:13:49.170 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 219.1 => 107.8 [Endpoint 0] 18:13:49.171 SERIAL » [ACK] (0x06) 18:13:49.172 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 107.8 18:13:49.262 SERIAL « 0x010c0004000c06310504220436dd (14 bytes) 18:13:49.264 CNTRLR [Node 012] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:13:49.265 CNTRLR [Node 012] [~] [Multilevel Sensor] Power: 0 => 107.8 [Endpoint 0] 18:13:49.266 SERIAL » [ACK] (0x06) 18:13:49.268 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 107.8 18:13:54.369 SERIAL « 0x010c0004000c06310504220000ef (14 bytes) 18:13:54.370 CNTRLR [Node 012] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:13:54.371 CNTRLR [Node 012] [~] [Multilevel Sensor] Power: 107.8 => 0 [Endpoint 0] 18:13:54.372 SERIAL » [ACK] (0x06) 18:13:54.373 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 18:13:54.564 SERIAL « 0x010900040011033003ff2c (11 bytes) 18:13:54.565 CNTRLR [Node 017] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:13:54.566 CNTRLR [Node 017] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:13:54.567 SERIAL » [ACK] (0x06) 18:13:54.568 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:13:54.619 SERIAL « 0x010900040011032001ff3e (11 bytes) 18:13:54.620 SERIAL » [ACK] (0x06) 18:13:54.620 DRIVER « [Node 017] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:13:54.622 CNTRLR [Node 017] treating BasicCC Set as a report 18:13:54.622 CNTRLR [Node 017] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:13:55.429 SERIAL « 0x01090004000c03260300d8 (11 bytes) 18:13:55.430 CNTRLR [Node 012] [~] [Multilevel Switch] currentValue: 39 => 0 [Endpoint 0] 18:13:55.430 SERIAL » [ACK] (0x06) 18:13:55.431 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[MultilevelSwitchCCReport] current value: 0 18:13:55.448 SERIAL « 0x010c0004000c06310504220000ef (14 bytes) 18:13:55.449 CNTRLR [Node 012] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:13:55.449 CNTRLR [Node 012] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 18:13:55.450 SERIAL » [ACK] (0x06) 18:13:55.450 DRIVER « [Node 012] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 18:13:58.515 SERIAL « 0x0110000400160a600d02003105012200a12e (18 bytes) 18:13:58.516 CNTRLR [Node 022] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 2] 18:13:58.518 CNTRLR [Node 022] [~] [Multilevel Sensor] Air temperature: 16 => 16.1 [Endpoint 2] 18:13:58.518 SERIAL » [ACK] (0x06) 18:13:58.520 DRIVER « [Node 022] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 16.1 18:13:58.732 SERIAL « 0x01090004101503300300c7 (11 bytes) 18:13:58.733 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:13:58.734 CNTRLR [Node 021] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:13:58.735 SERIAL » [ACK] (0x06) 18:13:58.737 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:13:58.818 SERIAL « 0x01090004101503300300c7 (11 bytes) 18:13:58.819 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:13:58.820 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:13:58.820 SERIAL » [ACK] (0x06) 18:13:58.821 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:13:58.830 SERIAL « 0x01090004101503300300c7 (11 bytes) 18:13:58.831 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:13:58.832 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:13:58.833 SERIAL » [ACK] (0x06) 18:13:58.834 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:13:58.839 SERIAL « 0x01090004101503300300c7 (11 bytes) 18:13:58.841 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:13:58.841 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:13:58.842 SERIAL » [ACK] (0x06) 18:13:58.843 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:13:58.907 SERIAL « 0x01090004101503300300c7 (11 bytes) 18:13:58.908 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:13:58.909 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:13:58.910 SERIAL » [ACK] (0x06) 18:13:58.911 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:13:58.951 SERIAL « 0x01090004101503300300c7 (11 bytes) 18:13:58.952 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:13:58.952 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:13:58.953 SERIAL » [ACK] (0x06) 18:13:58.954 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:13:59.002 SERIAL « 0x01090004101503300300c7 (11 bytes) 18:13:59.003 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:13:59.004 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:13:59.004 SERIAL » [ACK] (0x06) 18:13:59.006 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:13:59.040 SERIAL « 0x01090004101503300300c7 (11 bytes) 18:13:59.041 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:13:59.042 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:13:59.043 SERIAL » [ACK] (0x06) 18:13:59.044 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:13:59.062 SERIAL « 0x01090004101503300300c7 (11 bytes) 18:13:59.063 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:13:59.063 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:13:59.064 SERIAL » [ACK] (0x06) 18:13:59.065 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:13:59.068 SERIAL « 0x01090004101503300300c7 (11 bytes) 18:13:59.070 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:13:59.071 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:13:59.072 SERIAL » [ACK] (0x06) 18:13:59.073 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:13:59.158 SERIAL « 0x01090004001503200100c5 (11 bytes) 18:13:59.158 SERIAL » [ACK] (0x06) 18:13:59.159 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 0 18:13:59.160 CNTRLR [Node 021] treating BasicCC Set as a report 18:13:59.161 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:13:59.166 SERIAL « 0x01090004101503300300c7 (11 bytes) 18:13:59.167 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:13:59.167 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:13:59.168 SERIAL » [ACK] (0x06) 18:13:59.169 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:13:59.176 SERIAL « 0x01090004101503300300c7 (11 bytes) 18:13:59.176 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:13:59.177 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:13:59.178 SERIAL » [ACK] (0x06) 18:13:59.178 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:13:59.506 SERIAL « 0x01090004101503300300c7 (11 bytes) 18:13:59.507 CNTRLR [Node 021] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:13:59.508 CNTRLR [Node 021] [~] [Binary Sensor] Any: false => false [Endpoint 0] 18:13:59.509 SERIAL » [ACK] (0x06) 18:13:59.510 DRIVER « [Node 021] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:14:00.304 SERIAL « 0x010900040008033003ff35 (11 bytes) 18:14:00.305 CNTRLR [Node 008] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:14:00.307 CNTRLR [Node 008] [~] [Binary Sensor] Any: false => true [Endpoint 0] 18:14:00.308 SERIAL » [ACK] (0x06) 18:14:00.309 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: true 18:14:00.358 SERIAL « 0x010900040008032001ff27 (11 bytes) 18:14:00.358 SERIAL » [ACK] (0x06) 18:14:00.359 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BasicCCSet] target value: 255 18:14:00.360 CNTRLR [Node 008] treating BasicCC Set as a report 18:14:00.361 CNTRLR [Node 008] [~] [Binary Sensor] Any: true => true [Endpoint 0] 18:14:02.356 SERIAL « 0x01090004000703300300c5 (11 bytes) 18:14:02.357 CNTRLR [Node 007] [Binary Sensor] Any: metadata updated [Endpoint 0] 18:14:02.358 CNTRLR [Node 007] [~] [Binary Sensor] Any: true => false [Endpoint 0] 18:14:02.359 SERIAL » [ACK] (0x06) 18:14:02.360 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 18:14:02.600 SERIAL « 0x0110000400070a7105000000ff070000006a (18 bytes) 18:14:02.601 SERIAL » [ACK] (0x06) 18:14:02.602 DRIVER « [Node 007] [REQ] [ApplicationCommand] └─[NotificationCCReport] notification type: Home Security notification status: 255 notification event: Unknown (0x00) 18:14:02.634 CNTRLR [Node 007] [~] [Notification] Home Security[Motion sensor status] [Endpoint 0] : 8 => 0 18:14:09.169 SERIAL « 0x010c000400030631050422077790 (14 bytes) 18:14:09.170 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:14:09.171 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 107.8 => 191.1 [Endpoint 0] 18:14:09.171 SERIAL » [ACK] (0x06) 18:14:09.172 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 191.1 18:14:10.092 SERIAL « 0x01080004102002840742 (10 bytes) 18:14:10.092 SERIAL » [ACK] (0x06) 18:14:10.093 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 18:14:10.094 CNTRLR « [Node 032] received wakeup notification 18:14:10.094 CNTRLR [Node 032] The node is now awake. 18:14:10.101 SERIAL » 0x0109001320028405256102 (11 bytes) 18:14:10.102 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 97 └─[WakeUpCCIntervalGet] 18:14:10.103 SERIAL « [ACK] (0x06) 18:14:10.110 SERIAL « 0x0104011301e8 (6 bytes) 18:14:10.111 SERIAL » [ACK] (0x06) 18:14:10.111 DRIVER « [RES] [SendData] was sent: true 18:14:10.151 SERIAL « 0x01070013610000048e (9 bytes) 18:14:10.151 SERIAL » [ACK] (0x06) 18:14:10.152 DRIVER « [REQ] [SendData] callback id: 97 transmit status: OK 18:14:10.210 SERIAL « 0x01080004102002840742 (10 bytes) 18:14:10.211 SERIAL » [ACK] (0x06) 18:14:10.211 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 18:14:10.212 CNTRLR « [Node 032] received wakeup notification 18:14:10.342 SERIAL « 0x010c0004002006840600038401d5 (14 bytes) 18:14:10.343 CNTRLR [Node 032] [~] [Wake Up] wakeUpInterval: 900 => 900 [Endpoint 0] 18:14:10.343 CNTRLR [Node 032] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 18:14:10.344 SERIAL » [ACK] (0x06) 18:14:10.345 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 900 seconds controller node id: 1 18:14:10.351 SERIAL « 0x01080004102002840742 (10 bytes) 18:14:10.351 SERIAL » [ACK] (0x06) 18:14:10.352 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 18:14:10.353 CNTRLR « [Node 032] received wakeup notification 18:14:10.377 SERIAL « 0x01080004102002840742 (10 bytes) 18:14:10.377 SERIAL » [ACK] (0x06) 18:14:10.378 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 18:14:10.379 CNTRLR « [Node 032] received wakeup notification 18:14:10.400 SERIAL « 0x01080004102002840742 (10 bytes) 18:14:10.400 SERIAL » [ACK] (0x06) 18:14:10.401 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 18:14:10.404 CNTRLR « [Node 032] received wakeup notification 18:14:10.466 SERIAL « 0x01080004102002840742 (10 bytes) 18:14:10.466 SERIAL » [ACK] (0x06) 18:14:10.467 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 18:14:10.468 CNTRLR « [Node 032] received wakeup notification 18:14:10.478 SERIAL « 0x01080004102002840742 (10 bytes) 18:14:10.479 SERIAL » [ACK] (0x06) 18:14:10.479 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 18:14:10.480 CNTRLR « [Node 032] received wakeup notification 18:14:10.527 SERIAL « 0x01080004102002840742 (10 bytes) 18:14:10.528 SERIAL » [ACK] (0x06) 18:14:10.528 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 18:14:10.529 CNTRLR « [Node 032] received wakeup notification 18:14:10.823 SERIAL « 0x01080004102002840742 (10 bytes) 18:14:10.824 SERIAL » [ACK] (0x06) 18:14:10.825 DRIVER « [Node 032] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 18:14:10.827 CNTRLR « [Node 032] received wakeup notification 18:14:11.170 SERIAL « 0x010c00040003063105042203896a (14 bytes) 18:14:11.171 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:14:11.172 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 191.1 => 90.5 [Endpoint 0] 18:14:11.173 SERIAL » [ACK] (0x06) 18:14:11.174 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 90.5 18:14:11.828 CNTRLR » [Node 032] Sending node back to sleep... 18:14:11.832 SERIAL » 0x010900132002840825620c (11 bytes) 18:14:11.832 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 98 └─[WakeUpCCNoMoreInformation] 18:14:11.834 SERIAL « [ACK] (0x06) 18:14:11.840 SERIAL « 0x0104011301e8 (6 bytes) 18:14:11.841 SERIAL » [ACK] (0x06) 18:14:11.841 DRIVER « [RES] [SendData] was sent: true 18:14:11.902 SERIAL « 0x01070013620000068f (9 bytes) 18:14:11.903 SERIAL » [ACK] (0x06) 18:14:11.903 DRIVER « [REQ] [SendData] callback id: 98 transmit status: OK 18:14:11.909 CNTRLR [Node 032] The node is now asleep. 18:14:12.170 SERIAL « 0x010c000400030631050422077592 (14 bytes) 18:14:12.171 CNTRLR [Node 003] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 18:14:12.172 CNTRLR [Node 003] [~] [Multilevel Sensor] Power: 90.5 => 190.9 [Endpoint 0] 18:14:12.172 SERIAL » [ACK] (0x06) 18:14:12.174 DRIVER « [Node 003] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 190.9 18:14:17.890 DRIVER destroying driver instance...