12:18:38.379 DRIVER ███████╗ ██╗ ██╗ █████╗ ██╗ ██╗ ███████╗ ██╗ ███████╗ ╚══███╔╝ ██║ ██║ ██╔══██╗ ██║ ██║ ██╔════╝ ██║ ██╔════╝ ███╔╝ ██║ █╗ ██║ ███████║ ██║ ██║ █████╗ █████╗ ██║ ███████╗ ███╔╝ ██║███╗██║ ██╔══██║ ╚██╗ ██╔╝ ██╔══╝ ╚════╝ ██ ██║ ╚════██║ ███████╗ ╚███╔███╔╝ ██║ ██║ ╚████╔╝ ███████╗ ╚█████╔╝ ███████║ ╚══════╝ ╚══╝╚══╝ ╚═╝ ╚═╝ ╚═══╝ ╚══════╝ ╚════╝ ╚══════╝ 12:18:38.385 DRIVER version 5.3.6 12:18:38.386 DRIVER 12:18:38.387 DRIVER starting driver... 12:18:38.432 DRIVER opening serial port /dev/ttyZW 12:18:38.518 DRIVER serial port opened 12:18:38.523 SERIAL » [NAK] (0x15) 12:18:40.032 DRIVER loading configuration... 12:18:40.596 DRIVER beginning interview... 12:18:40.597 DRIVER added request handler for AddNodeToNetwork (0x4a)... 1 registered 12:18:40.598 DRIVER added request handler for RemoveNodeFromNetwork (0x4b)... 1 registered 12:18:40.601 CNTRLR beginning interview... 12:18:40.601 CNTRLR querying version info... 12:18:40.814 SERIAL » 0x01030015e9 (5 bytes) 12:18:40.818 DRIVER » [REQ] [GetControllerVersion] 12:18:40.823 SERIAL « [ACK] (0x06) 12:18:40.827 SERIAL « 0x011001155a2d5761766520342e3534000193 (18 bytes) 12:18:40.829 SERIAL » [ACK] (0x06) 12:18:40.831 DRIVER « [RES] [GetControllerVersion] payload: 0x5a2d5761766520342e35340001 12:18:40.845 CNTRLR received version info: controller type: Static Controller library version: Z-Wave 4.54 12:18:40.845 CNTRLR querying controller IDs... 12:18:40.854 SERIAL » 0x01030020dc (5 bytes) 12:18:40.855 DRIVER » [REQ] [GetControllerId] 12:18:40.858 SERIAL « [ACK] (0x06) 12:18:40.861 SERIAL « 0x01080120caf81a84017b (10 bytes) 12:18:40.864 SERIAL » [ACK] (0x06) 12:18:40.867 DRIVER « [RES] [GetControllerId] payload: 0xcaf81a8401 12:18:40.876 CNTRLR received controller IDs: home ID: 0xcaf81a84 own node ID: 1 12:18:40.876 CNTRLR querying controller capabilities... 12:18:40.887 SERIAL » 0x01030005f9 (5 bytes) 12:18:40.888 DRIVER » [REQ] [GetControllerCapabilities] 12:18:40.892 SERIAL « [ACK] (0x06) 12:18:40.895 SERIAL « 0x0104010508f7 (6 bytes) 12:18:40.897 SERIAL » [ACK] (0x06) 12:18:40.898 DRIVER « [RES] [GetControllerCapabilities] payload: 0x08 12:18:40.905 CNTRLR received controller capabilities: controller role: primary is in other network: false is SIS present: false was real primary: true is a SUC: false 12:18:40.906 CNTRLR querying API capabilities... 12:18:40.916 SERIAL » 0x01030007fb (5 bytes) 12:18:40.917 DRIVER » [REQ] [GetSerialApiCapabilities] 12:18:40.920 SERIAL « [ACK] (0x06) 12:18:40.923 SERIAL « 0x012b0107010100860001005afe81ff884f1f0000fb9f7da067000080008086000 (45 bytes) 000e87300000e0000600000fa 12:18:40.924 SERIAL » [ACK] (0x06) 12:18:40.926 DRIVER « [RES] [GetSerialApiCapabilities] payload: 0x010100860001005afe81ff884f1f0000fb9f7da067000080008086000000e8730 0000e0000600000 12:18:40.932 CNTRLR received API capabilities: serial API version: 1.1 manufacturer ID: 0x86 product type: 0x01 product ID: 0x5a supported functions: · GetSerialApiInitData (0x02) · FUNC_ID_SERIAL_API_APPL_NODE_INFORMATION (0x03) · ApplicationCommand (0x04) · GetControllerCapabilities (0x05) · SetSerialApiTimeouts (0x06) · GetSerialApiCapabilities (0x07) · FUNC_ID_SERIAL_API_SOFT_RESET (0x08) · UNKNOWN_FUNC_UNKNOWN_0x09 (0x09) · UNKNOWN_FUNC_RF_RECEIVE_MODE (0x10) · UNKNOWN_FUNC_SET_SLEEP_MODE (0x11) · FUNC_ID_ZW_SEND_NODE_INFORMATION (0x12) · SendData (0x13) · SendDataMulticast (0x14) · GetControllerVersion (0x15) · SendDataAbort (0x16) · FUNC_ID_ZW_R_F_POWER_LEVEL_SET (0x17) · UNKNOWN_FUNC_SEND_DATA_META (0x18) · FUNC_ID_ZW_GET_RANDOM (0x1c) · GetControllerId (0x20) · UNKNOWN_FUNC_MEMORY_GET_BYTE (0x21) · UNKNOWN_FUNC_MEMORY_PUT_BYTE (0x22) · UNKNOWN_FUNC_MEMORY_GET_BUFFER (0x23) · UNKNOWN_FUNC_MEMORY_PUT_BUFFER (0x24) · UNKNOWN_FUNC_FlashAutoProgSet (0x27) · UNKNOWN_FUNC_NVMGetId (0x29) · UNKNOWN_FUNC_NVMExtReadLongBuffer (0x2a) · UNKNOWN_FUNC_NVMExtWriteLongBuffer (0x2b) · UNKNOWN_FUNC_NVMExtReadLongByte (0x2c) · UNKNOWN_FUNC_NVMExtWriteLongByte (0x2d) · GetNodeProtocolInfo (0x41) · HardReset (0x42) · FUNC_ID_ZW_REPLICATION_COMMAND_COMPLETE (0x44) · FUNC_ID_ZW_REPLICATION_SEND_DATA (0x45) · AssignReturnRoute (0x46) · DeleteReturnRoute (0x47) · RequestNodeNeighborUpdate (0x48) · ApplicationUpdateRequest (0x49) · AddNodeToNetwork (0x4a) · RemoveNodeFromNetwork (0x4b) · FUNC_ID_ZW_CREATE_NEW_PRIMARY (0x4c) · FUNC_ID_ZW_CONTROLLER_CHANGE (0x4d) · FUNC_ID_ZW_SET_LEARN_MODE (0x50) · FUNC_ID_ZW_ASSIGN_SUC_RETURN_ROUTE (0x51) · FUNC_ID_ZW_REQUEST_NETWORK_UPDATE (0x53) · FUNC_ID_ZW_SET_SUC_NODE_ID (0x54) · FUNC_ID_ZW_DELETE_SUC_RETURN_ROUTE (0x55) · GetSUCNodeId (0x56) · UNKNOWN_FUNC_SEND_SUC_ID (0x57) · FUNC_ID_ZW_EXPLORE_REQUEST_INCLUSION (0x5e) · RequestNodeInfo (0x60) · RemoveFailedNode (0x61) · IsFailedNode (0x62) · FUNC_ID_ZW_REPLACE_FAILED_NODE (0x63) · UNKNOWN_FUNC_UNKNOWN_0x66 (0x66) · UNKNOWN_FUNC_UNKNOWN_0x67 (0x67) · GetRoutingInfo (0x80) · UNKNOWN_FUNC_LOCK_ROUTE_RESPONSE (0x90) · UNKNOWN_FUNC_GET_PRIORITY_ROUTE (0x92) · UNKNOWN_FUNC_SET_PRIORITY_ROUTE (0x93) · UNKNOWN_FUNC_UNKNOWN_0x98 (0x98) · UNKNOWN_FUNC_UNKNOWN_0xB4 (0xb4) · UNKNOWN_FUNC_WATCH_DOG_ENABLE (0xb6) · UNKNOWN_FUNC_WATCH_DOG_DISABLE (0xb7) · UNKNOWN_FUNC_WATCH_DOG_KICK (0xb8) · UNKNOWN_FUNC_UNKNOWN_0xB9 (0xb9) · UNKNOWN_FUNC_RF_POWERLEVEL_GET (0xba) · UNKNOWN_FUNC_GET_LIBRARY_TYPE (0xbd) · UNKNOWN_FUNC_SEND_TEST_FRAME (0xbe) · UNKNOWN_FUNC_GET_PROTOCOL_STATUS (0xbf) · UNKNOWN_FUNC_UNKNOWN_0xD2 (0xd2) · UNKNOWN_FUNC_UNKNOWN_0xD3 (0xd3) · UNKNOWN_FUNC_UNKNOWN_0xD4 (0xd4) · undefined (0xee) · UNKNOWN_FUNC_UNKNOWN_0xEF (0xef) 12:18:40.933 CNTRLR finding SUC... 12:18:40.940 SERIAL » 0x01030056aa (5 bytes) 12:18:40.941 DRIVER » [REQ] [GetSUCNodeId] 12:18:40.944 SERIAL « [ACK] (0x06) 12:18:40.946 SERIAL « 0x0104015600ac (6 bytes) 12:18:40.947 SERIAL » [ACK] (0x06) 12:18:40.948 DRIVER « [RES] [GetSUCNodeId] payload: 0x00 12:18:40.970 CNTRLR no SUC present 12:18:41.229 CNTRLR querying node information... 12:18:41.243 SERIAL » 0x01030002fe (5 bytes) 12:18:41.244 DRIVER » [REQ] [GetSerialApiInitData] 12:18:41.246 SERIAL « [ACK] (0x06) 12:18:41.344 SERIAL « 0x0125010205001d8900d0f53f00000000000000000000000000000000000000000 (39 bytes) 0000000050057 12:18:41.345 SERIAL » [ACK] (0x06) 12:18:41.346 DRIVER « [RES] [GetSerialApiInitData] payload: 0x05001d8900d0f53f0000000000000000000000000000000000000000000000000 500 12:18:41.351 CNTRLR received node information: controller role: primary controller is a SUC: false controller is a slave: false controller supports timers: false nodes in the network: 1, 4, 8, 21, 23, 24, 25, 27, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38 12:18:41.420 DRIVER Cache file for homeId 0xcaf81a84 found, attempting to restore the network from cache... 12:18:41.428 CNTRLR [Node 001] trying to load device config 12:18:41.439 CNTRLR [Node 001] device config loaded 12:18:41.440 CNTRLR [Node 004] trying to load device config 12:18:41.460 CNTRLR [Node 004] device config loaded 12:18:41.461 CNTRLR [Node 008] trying to load device config 12:18:41.470 CNTRLR [Node 008] device config loaded 12:18:41.471 CNTRLR [Node 021] trying to load device config 12:18:41.479 CNTRLR [Node 021] device config loaded 12:18:41.480 CNTRLR [Node 023] trying to load device config 12:18:41.496 CNTRLR [Node 023] device config loaded 12:18:41.496 CNTRLR [Node 024] trying to load device config 12:18:41.507 CNTRLR [Node 024] device config loaded 12:18:41.508 CNTRLR [Node 025] trying to load device config 12:18:41.521 CNTRLR [Node 025] device config loaded 12:18:41.523 CNTRLR [Node 027] trying to load device config 12:18:41.533 CNTRLR [Node 027] device config loaded 12:18:41.534 CNTRLR [Node 029] trying to load device config 12:18:41.544 CNTRLR [Node 029] device config loaded 12:18:41.545 CNTRLR [Node 030] trying to load device config 12:18:41.556 CNTRLR [Node 030] device config loaded 12:18:41.557 CNTRLR [Node 031] trying to load device config 12:18:41.567 CNTRLR [Node 031] device config loaded 12:18:41.568 CNTRLR [Node 032] trying to load device config 12:18:41.580 CNTRLR [Node 032] device config loaded 12:18:41.581 CNTRLR [Node 033] trying to load device config 12:18:41.591 CNTRLR [Node 033] device config loaded 12:18:41.593 CNTRLR [Node 034] trying to load device config 12:18:41.603 CNTRLR [Node 034] device config loaded 12:18:41.604 CNTRLR [Node 035] trying to load device config 12:18:41.617 CNTRLR [Node 035] device config loaded 12:18:41.618 CNTRLR [Node 036] trying to load device config 12:18:41.631 CNTRLR [Node 036] device config loaded 12:18:41.632 CNTRLR [Node 037] trying to load device config 12:18:41.645 CNTRLR [Node 037] device config loaded 12:18:41.646 CNTRLR [Node 038] trying to load device config 12:18:41.657 CNTRLR [Node 038] device config loaded 12:18:41.657 DRIVER Restoring the network from cache was successful! 12:18:41.663 CNTRLR [Node 001] [Manufacturer Specific] manufacturerId: metadata updated 12:18:41.664 CNTRLR [Node 001] [Manufacturer Specific] productType: metadata updated 12:18:41.665 CNTRLR [Node 001] [Manufacturer Specific] productId: metadata updated 12:18:41.666 CNTRLR [Node 001] [~] [Manufacturer Specific] manufacturerId: 134 => 134 12:18:41.667 CNTRLR [Node 001] [~] [Manufacturer Specific] productType: 1 => 1 12:18:41.667 CNTRLR [Node 001] [~] [Manufacturer Specific] productId: 90 => 90 12:18:41.668 CNTRLR setting serial API timeouts: ack = 1000 ms, byte = 150 ms 12:18:41.674 SERIAL » 0x01050006640f97 (7 bytes) 12:18:41.675 DRIVER » [REQ] [SetSerialApiTimeouts] payload: 0x640f 12:18:41.677 SERIAL « [ACK] (0x06) 12:18:41.679 SERIAL « 0x01050106640f96 (7 bytes) 12:18:41.680 SERIAL » [ACK] (0x06) 12:18:41.681 DRIVER « [RES] [SetSerialApiTimeouts] payload: 0x640f 12:18:41.686 CNTRLR serial API timeouts overwritten. The old values were: ack = 1000 ms, byte = 15 0 ms 12:18:41.686 CNTRLR Interview completed 12:18:41.689 DRIVER driver ready 12:18:41.694 CNTRLR [Node 001] Beginning interview - last completed stage: RestartFromCache 12:18:41.695 CNTRLR [Node 001] not pinging the controller 12:18:41.701 CNTRLR [Node 001] WakeUpCC: doing a partial interview... 12:18:41.702 CNTRLR [Node 001] skipping wakeup configuration for the controller 12:18:41.703 CNTRLR [Node 001] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:18:41.729 CNTRLR [Node 001] Interview stage completed: CommandClasses 12:18:41.730 CNTRLR [Node 001] trying to load device config 12:18:41.736 CNTRLR [Node 001] device config loaded 12:18:41.737 CNTRLR [Node 001] Interview stage completed: OverwriteConfig 12:18:41.738 CNTRLR » [Node 001] requesting node neighbors... 12:18:41.817 SERIAL » 0x010700800100000079 (9 bytes) 12:18:41.818 DRIVER » [Node 001] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 12:18:41.825 SERIAL « [ACK] (0x06) 12:18:41.827 SERIAL « 0x012001808800d0f53f00000000000000000000000000000000000000000000000 (34 bytes) 0cc 12:18:41.828 SERIAL » [ACK] (0x06) 12:18:41.830 DRIVER « [RES] [GetRoutingInfo] node ids: 4, 8, 21, 23, 24, 25, 27, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38 12:18:41.837 CNTRLR « [Node 001] node neighbors received: 4, 8, 21, 23, 24, 25, 27, 29, 30, 31, 32 , 33, 34, 35, 36, 37, 38 12:18:41.837 CNTRLR [Node 001] Interview stage completed: Neighbors 12:18:41.838 CNTRLR [Node 001] Interview completed 12:18:41.838 CNTRLR [Node 001] The node is ready to be used 12:18:41.842 CNTRLR [Node 004] Beginning interview - last completed stage: RestartFromCache 12:18:41.843 CNTRLR » [Node 004] pinging the node... 12:18:41.854 SERIAL » 0x010800130401002501c5 (10 bytes) 12:18:41.855 DRIVER » [Node 004] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 1 └─[NoOperationCC] 12:18:41.856 CNTRLR [Node 008] Beginning interview - last completed stage: RestartFromCache 12:18:41.856 CNTRLR » [Node 008] pinging the node... 12:18:41.859 CNTRLR [Node 021] Beginning interview - last completed stage: RestartFromCache 12:18:41.860 CNTRLR » [Node 021] pinging the node... 12:18:41.863 CNTRLR [Node 023] Beginning interview - last completed stage: RestartFromCache 12:18:41.864 CNTRLR » [Node 023] pinging the node... 12:18:41.867 CNTRLR [Node 024] Beginning interview - last completed stage: RestartFromCache 12:18:41.868 CNTRLR » [Node 024] pinging the node... 12:18:41.870 CNTRLR [Node 025] Beginning interview - last completed stage: RestartFromCache 12:18:41.871 CNTRLR » [Node 025] pinging the node... 12:18:41.874 CNTRLR [Node 027] Beginning interview - last completed stage: RestartFromCache 12:18:41.875 CNTRLR » [Node 027] pinging the node... 12:18:41.877 CNTRLR [Node 029] Beginning interview - last completed stage: RestartFromCache 12:18:41.878 CNTRLR » [Node 029] pinging the node... 12:18:41.881 CNTRLR [Node 030] Beginning interview - last completed stage: RestartFromCache 12:18:41.882 CNTRLR » [Node 030] pinging the node... 12:18:41.884 CNTRLR [Node 031] Beginning interview - last completed stage: RestartFromCache 12:18:41.885 CNTRLR » [Node 031] pinging the node... 12:18:41.888 CNTRLR [Node 032] Beginning interview - last completed stage: RestartFromCache 12:18:41.889 CNTRLR » [Node 032] pinging the node... 12:18:41.891 CNTRLR [Node 033] Beginning interview - last completed stage: RestartFromCache 12:18:41.892 CNTRLR » [Node 033] pinging the node... 12:18:41.895 CNTRLR [Node 034] Beginning interview - last completed stage: RestartFromCache 12:18:41.895 CNTRLR » [Node 034] pinging the node... 12:18:41.898 CNTRLR [Node 035] Beginning interview - last completed stage: RestartFromCache 12:18:41.899 CNTRLR » [Node 035] pinging the node... 12:18:41.901 CNTRLR [Node 036] Beginning interview - last completed stage: RestartFromCache 12:18:41.902 CNTRLR » [Node 036] pinging the node... 12:18:41.904 CNTRLR [Node 037] Beginning interview - last completed stage: RestartFromCache 12:18:41.905 CNTRLR » [Node 037] pinging the node... 12:18:41.908 CNTRLR [Node 038] Beginning interview - last completed stage: RestartFromCache 12:18:41.909 CNTRLR » [Node 038] pinging the node... 12:18:41.924 SERIAL « [ACK] (0x06) 12:18:41.926 SERIAL « 0x0104011301e8 (6 bytes) 12:18:41.927 SERIAL » [ACK] (0x06) 12:18:41.942 DRIVER « [RES] [SendData] was sent: true 12:18:42.842 CNTRLR » [Node 001] Sending node back to sleep... 12:18:46.055 SERIAL « 0x010700130101019e74 (9 bytes) 12:18:46.056 SERIAL » [ACK] (0x06) 12:18:46.058 DRIVER « [REQ] [SendData] callback id: 1 transmit status: NoAck 12:18:46.069 SERIAL » 0x010800130801002502ca (10 bytes) 12:18:46.069 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 2 └─[NoOperationCC] 12:18:46.070 CNTRLR [Node 004] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 12:18:46.072 CNTRLR [Node 004] The node is asleep. 12:18:46.075 CNTRLR [Node 004] The node is ready to be used 12:18:46.076 CNTRLR [Node 004] ping failed: Failed to send the command after 1 attempts (Status No Ack) 12:18:46.079 CNTRLR [Node 004] ManufacturerSpecificCC: doing a partial interview... 12:18:46.080 CNTRLR [Node 004] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 12:18:46.093 SERIAL « [ACK] (0x06) 12:18:46.095 SERIAL « 0x0104011301e8 (6 bytes) 12:18:46.095 SERIAL » [ACK] (0x06) 12:18:46.098 DRIVER « [RES] [SendData] was sent: true 12:18:46.107 CNTRLR [Node 004] VersionCC: doing a partial interview... 12:18:46.107 CNTRLR [Node 004] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:18:46.108 CNTRLR [Node 004] trying to load device config 12:18:46.126 CNTRLR [Node 004] device config loaded 12:18:46.128 CNTRLR [Node 004] BatteryCC: doing a partial interview... 12:18:46.129 CNTRLR » [Node 004] querying battery status... 12:18:47.470 SERIAL « 0x010700130200008b62 (9 bytes) 12:18:47.471 SERIAL » [ACK] (0x06) 12:18:47.474 DRIVER « [REQ] [SendData] callback id: 2 transmit status: OK 12:18:47.482 SERIAL » 0x010800131501002503d6 (10 bytes) 12:18:47.483 DRIVER » [Node 021] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 3 └─[NoOperationCC] 12:18:47.483 CNTRLR « [Node 008] ping successful 12:18:47.486 CNTRLR [Node 008] ManufacturerSpecificCC: doing a partial interview... 12:18:47.486 CNTRLR [Node 008] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 12:18:47.499 SERIAL « [ACK] (0x06) 12:18:47.502 SERIAL « 0x0104011301e8 (6 bytes) 12:18:47.503 SERIAL » [ACK] (0x06) 12:18:47.506 DRIVER « [RES] [SendData] was sent: true 12:18:47.509 CNTRLR [Node 008] VersionCC: doing a partial interview... 12:18:47.510 CNTRLR [Node 008] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:18:47.510 CNTRLR [Node 008] trying to load device config 12:18:47.522 CNTRLR [Node 008] device config loaded 12:18:47.523 CNTRLR [Node 008] ZWavePlusCC: doing a partial interview... 12:18:47.524 CNTRLR [Node 008] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 12:18:47.525 CNTRLR [Node 008] BatteryCC: doing a partial interview... 12:18:47.525 CNTRLR » [Node 008] querying battery status... 12:18:51.567 SERIAL « 0x010700130301019870 (9 bytes) 12:18:51.568 SERIAL » [ACK] (0x06) 12:18:51.569 DRIVER « [REQ] [SendData] callback id: 3 transmit status: NoAck 12:18:51.578 SERIAL » 0x010800131701002504d3 (10 bytes) 12:18:51.579 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 4 └─[NoOperationCC] 12:18:51.580 CNTRLR [Node 021] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 12:18:51.580 CNTRLR [Node 021] The node is asleep. 12:18:51.582 CNTRLR [Node 021] The node is ready to be used 12:18:51.583 CNTRLR [Node 021] ping failed: Failed to send the command after 1 attempts (Status No Ack) 12:18:51.587 CNTRLR [Node 021] ManufacturerSpecificCC: doing a partial interview... 12:18:51.588 CNTRLR [Node 021] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 12:18:51.598 SERIAL « [ACK] (0x06) 12:18:51.600 SERIAL « 0x0104011301e8 (6 bytes) 12:18:51.601 SERIAL » [ACK] (0x06) 12:18:51.604 DRIVER « [RES] [SendData] was sent: true 12:18:51.613 CNTRLR [Node 021] VersionCC: doing a partial interview... 12:18:51.614 CNTRLR [Node 021] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:18:51.615 CNTRLR [Node 021] trying to load device config 12:18:51.616 SERIAL « 0x0107001304000002ed (9 bytes) 12:18:51.617 SERIAL » [ACK] (0x06) 12:18:51.619 DRIVER « [REQ] [SendData] callback id: 4 transmit status: OK 12:18:51.635 SERIAL » 0x010900130802800225054d (11 bytes) 12:18:51.636 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 5 └─[BatteryCCGet] 12:18:51.636 CNTRLR « [Node 023] ping successful 12:18:51.644 CNTRLR [Node 023] ManufacturerSpecificCC: doing a partial interview... 12:18:51.645 CNTRLR [Node 023] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 12:18:51.646 CNTRLR [Node 023] VersionCC: doing a partial interview... 12:18:51.646 CNTRLR [Node 023] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:18:51.647 CNTRLR [Node 023] trying to load device config 12:18:51.812 SERIAL « [ACK] (0x06) 12:18:51.814 SERIAL « 0x0104011301e8 (6 bytes) 12:18:51.814 SERIAL » [ACK] (0x06) 12:18:51.816 DRIVER « [RES] [SendData] was sent: true 12:18:51.832 CNTRLR [Node 021] device config loaded 12:18:51.833 CNTRLR [Node 021] BatteryCC: doing a partial interview... 12:18:51.833 CNTRLR » [Node 021] querying battery status... 12:18:51.850 CNTRLR [Node 023] device config loaded 12:18:51.851 CNTRLR [Node 023] ZWavePlusCC: doing a partial interview... 12:18:51.851 CNTRLR [Node 023] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 12:18:51.852 CNTRLR [Node 023] BinarySwitchCC: doing a partial interview... 12:18:51.853 CNTRLR » [Node 023] querying Binary Switch state... 12:18:53.051 SERIAL « 0x010700130500008e60 (9 bytes) 12:18:53.052 SERIAL » [ACK] (0x06) 12:18:53.053 DRIVER « [REQ] [SendData] callback id: 5 transmit status: OK 12:18:53.130 SERIAL « 0x010900040008038003641e (11 bytes) 12:18:53.135 CNTRLR [Node 008] [~] [Battery] level: 100 => 100 [Endpoint 0] 12:18:53.136 CNTRLR [Node 008] [~] [Battery] isLow: false => false [Endpoint 0] 12:18:53.137 SERIAL » [ACK] (0x06) 12:18:53.140 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 12:18:53.146 SERIAL » 0x01090013170225022506f4 (11 bytes) 12:18:53.147 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 6 └─[BinarySwitchCCGet] 12:18:53.148 CNTRLR [Node 008] The node is alive. 12:18:53.149 CNTRLR [Node 008] The node is ready to be used 12:18:53.151 CNTRLR « [Node 008] received response for battery information: level: 100 12:18:53.152 CNTRLR [Node 008] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:18:53.170 SERIAL « [ACK] (0x06) 12:18:53.173 SERIAL « 0x0104011301e8 (6 bytes) 12:18:53.174 SERIAL » [ACK] (0x06) 12:18:53.177 DRIVER « [RES] [SendData] was sent: true 12:18:53.182 SERIAL « 0x0107001306000002ef (9 bytes) 12:18:53.182 SERIAL » [ACK] (0x06) 12:18:53.184 DRIVER « [REQ] [SendData] callback id: 6 transmit status: OK 12:18:53.188 SERIAL « 0x01090004001703250300c0 (11 bytes) 12:18:53.190 CNTRLR [Node 023] [~] [Binary Switch] currentValue: false => false [Endpoint 0] 12:18:53.190 SERIAL » [ACK] (0x06) 12:18:53.192 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 12:18:53.197 SERIAL » 0x010800131801002507df (10 bytes) 12:18:53.198 DRIVER » [Node 024] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 7 └─[NoOperationCC] 12:18:53.199 CNTRLR [Node 023] The node is alive. 12:18:53.200 CNTRLR [Node 023] The node is ready to be used 12:18:53.202 CNTRLR « [Node 023] received Binary Switch state: current value: false 12:18:53.203 CNTRLR [Node 023] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 12:18:53.205 CNTRLR [Node 023] MultilevelSensorCC: doing a partial interview... 12:18:53.205 CNTRLR » [Node 023] querying Power sensor reading... 12:18:53.220 SERIAL « [ACK] (0x06) 12:18:53.222 SERIAL « 0x0104011301e8 (6 bytes) 12:18:53.223 SERIAL » [ACK] (0x06) 12:18:53.225 DRIVER « [RES] [SendData] was sent: true 12:18:53.840 CNTRLR [Node 008] BinarySwitchCC: doing a partial interview... 12:18:53.840 CNTRLR » [Node 008] querying Binary Switch state... 12:18:59.873 SERIAL « 0x010700130701029b74 (9 bytes) 12:18:59.874 SERIAL » [ACK] (0x06) 12:18:59.875 DRIVER « [REQ] [SendData] callback id: 7 transmit status: NoAck 12:18:59.884 SERIAL » 0x010b00131704310404002508e8 (13 bytes) 12:18:59.885 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 8 └─[MultilevelSensorCCGet] sensor type: Power scale: Watt 12:18:59.886 CNTRLR [Node 024] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 12:18:59.886 CNTRLR [Node 024] The node is asleep. 12:18:59.888 CNTRLR [Node 024] The node is ready to be used 12:18:59.889 CNTRLR [Node 024] ping failed: Failed to send the command after 1 attempts (Status No Ack) 12:18:59.893 CNTRLR [Node 024] ManufacturerSpecificCC: doing a partial interview... 12:18:59.893 CNTRLR [Node 024] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 12:18:59.905 SERIAL « [ACK] (0x06) 12:18:59.908 SERIAL « 0x0104011301e8 (6 bytes) 12:18:59.909 SERIAL » [ACK] (0x06) 12:18:59.911 DRIVER « [RES] [SendData] was sent: true 12:18:59.918 CNTRLR [Node 024] VersionCC: doing a partial interview... 12:18:59.918 CNTRLR [Node 024] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:18:59.919 CNTRLR [Node 024] trying to load device config 12:18:59.922 SERIAL « 0x0107001308000002e1 (9 bytes) 12:18:59.922 SERIAL » [ACK] (0x06) 12:18:59.923 DRIVER « [REQ] [SendData] callback id: 8 transmit status: OK 12:18:59.935 CNTRLR [Node 024] device config loaded 12:18:59.936 CNTRLR [Node 024] ZWavePlusCC: doing a partial interview... 12:18:59.936 CNTRLR [Node 024] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 12:18:59.937 CNTRLR [Node 024] BatteryCC: doing a partial interview... 12:18:59.938 CNTRLR » [Node 024] querying battery status... 12:18:59.942 SERIAL « 0x010c0004001706310504220000f4 (14 bytes) 12:18:59.945 CNTRLR [Node 023] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 12:18:59.947 CNTRLR [Node 023] [~] [Multilevel Sensor] Power: 0 => 0 [Endpoint 0] 12:18:59.948 SERIAL » [ACK] (0x06) 12:18:59.950 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 0 12:18:59.958 SERIAL » 0x01090013080225022509e4 (11 bytes) 12:18:59.959 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 9 └─[BinarySwitchCCGet] 12:18:59.960 CNTRLR « [Node 023] received current Power sensor reading: 0 W 12:18:59.960 CNTRLR [Node 023] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 12:18:59.963 CNTRLR [Node 023] MeterCC: doing a partial interview... 12:18:59.964 CNTRLR » [Node 023] querying meter value (type = Electric, scale = kWh)... 12:19:00.187 SERIAL « [ACK] (0x06) 12:19:00.189 SERIAL « 0x0104011301e8 (6 bytes) 12:19:00.189 SERIAL » [ACK] (0x06) 12:19:00.191 DRIVER « [RES] [SendData] was sent: true 12:19:01.373 SERIAL « 0x010700130900008d6f (9 bytes) 12:19:01.373 SERIAL » [ACK] (0x06) 12:19:01.374 DRIVER « [REQ] [SendData] callback id: 9 transmit status: OK 12:19:01.458 SERIAL « 0x01090004000803250300df (11 bytes) 12:19:01.460 CNTRLR [Node 008] [~] [Binary Switch] currentValue: false => false [Endpoint 0] 12:19:01.462 SERIAL » [ACK] (0x06) 12:19:01.464 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 12:19:01.474 SERIAL » 0x010a00131703320100250aee (12 bytes) 12:19:01.476 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 10 └─[MeterCCGet] duration: kWh 12:19:01.477 CNTRLR « [Node 008] received Binary Switch state: current value: false 12:19:01.478 CNTRLR [Node 008] [~] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] => true 12:19:01.480 CNTRLR [Node 008] BinarySensorCC: doing a partial interview... 12:19:01.481 CNTRLR » [Node 008] querying current value for Aux... 12:19:01.500 SERIAL « [ACK] (0x06) 12:19:01.504 SERIAL « 0x0104011301e8 (6 bytes) 12:19:01.505 SERIAL » [ACK] (0x06) 12:19:01.506 DRIVER « [RES] [SendData] was sent: true 12:19:01.545 SERIAL « 0x010700130a000007e6 (9 bytes) 12:19:01.546 SERIAL » [ACK] (0x06) 12:19:01.547 DRIVER « [REQ] [SendData] callback id: 10 transmit status: OK 12:19:01.557 SERIAL « 0x0110000400170a32022144000000000000a3 (18 bytes) 12:19:01.560 CNTRLR [Node 023] [~] [Meter] value[65537]: 0 => 0 [Endpoint 0] 12:19:01.561 CNTRLR [Node 023] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 12:19:01.562 SERIAL » [ACK] (0x06) 12:19:01.564 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 0 time delta: 0 seconds 12:19:01.570 SERIAL » 0x010a00130803300209250bf8 (12 bytes) 12:19:01.571 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 11 └─[BinarySensorCCGet] type: Aux 12:19:01.572 CNTRLR » [Node 023] querying meter value (type = Electric, scale = W)... 12:19:01.577 SERIAL « [ACK] (0x06) 12:19:01.581 SERIAL « 0x0104011301e8 (6 bytes) 12:19:01.581 SERIAL » [ACK] (0x06) 12:19:01.583 DRIVER « [RES] [SendData] was sent: true 12:19:01.633 SERIAL « 0x010700130b000006e6 (9 bytes) 12:19:01.634 SERIAL » [ACK] (0x06) 12:19:01.634 DRIVER « [REQ] [SendData] callback id: 11 transmit status: OK 12:19:01.718 SERIAL « 0x010a000400080430030008c6 (12 bytes) 12:19:01.720 CNTRLR [Node 008] [Binary Sensor] Tamper: metadata updated [Endpoint 0] 12:19:01.721 CNTRLR [Node 008] [~] [Binary Sensor] Tamper: false => false [Endpoint 0] 12:19:01.722 SERIAL » [ACK] (0x06) 12:19:01.723 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Tamper value: false 12:19:03.239 CNTRLR [Node 008] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 12:19:03.751 SERIAL » 0x010a00130803300209250bf8 (12 bytes) 12:19:03.752 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 11 └─[BinarySensorCCGet] type: Aux 12:19:03.755 SERIAL « [ACK] (0x06) 12:19:03.761 SERIAL « 0x0104011301e8 (6 bytes) 12:19:03.762 SERIAL » [ACK] (0x06) 12:19:03.764 DRIVER « [RES] [SendData] was sent: true 12:19:03.815 SERIAL « 0x010700130b000006e6 (9 bytes) 12:19:03.816 SERIAL » [ACK] (0x06) 12:19:03.816 DRIVER « [REQ] [SendData] callback id: 11 transmit status: OK 12:19:03.898 SERIAL « 0x010a000400080430030008c6 (12 bytes) 12:19:03.899 CNTRLR [Node 008] [Binary Sensor] Tamper: metadata updated [Endpoint 0] 12:19:03.900 CNTRLR [Node 008] [~] [Binary Sensor] Tamper: false => false [Endpoint 0] 12:19:03.901 SERIAL » [ACK] (0x06) 12:19:03.902 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Tamper value: false 12:19:05.420 CNTRLR [Node 008] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 12:19:05.925 SERIAL » 0x010a00130803300209250bf8 (12 bytes) 12:19:05.925 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 11 └─[BinarySensorCCGet] type: Aux 12:19:05.927 SERIAL « [ACK] (0x06) 12:19:05.934 SERIAL « 0x0104011301e8 (6 bytes) 12:19:05.934 SERIAL » [ACK] (0x06) 12:19:05.935 DRIVER « [RES] [SendData] was sent: true 12:19:05.988 SERIAL « 0x010700130b000006e6 (9 bytes) 12:19:05.988 SERIAL » [ACK] (0x06) 12:19:05.989 DRIVER « [REQ] [SendData] callback id: 11 transmit status: OK 12:19:06.069 SERIAL « 0x010a000400080430030008c6 (12 bytes) 12:19:06.071 CNTRLR [Node 008] [Binary Sensor] Tamper: metadata updated [Endpoint 0] 12:19:06.072 CNTRLR [Node 008] [~] [Binary Sensor] Tamper: false => false [Endpoint 0] 12:19:06.077 SERIAL » [ACK] (0x06) 12:19:06.078 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Tamper value: false 12:19:07.603 SERIAL » 0x010a00131703320110250cf8 (12 bytes) 12:19:07.604 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 12 └─[MeterCCGet] duration: W 12:19:07.606 CNTRLR [Node 008] Current value query for Aux timed out - skipping because it is not critical... 12:19:07.607 CNTRLR [Node 008] [~] [Binary Sensor] interviewComplete: true [Endpoint 0] [internal] => true 12:19:07.623 SERIAL « [ACK] (0x06) 12:19:07.627 SERIAL « 0x0104011301e8 (6 bytes) 12:19:07.628 SERIAL » [ACK] (0x06) 12:19:07.629 DRIVER « [RES] [SendData] was sent: true 12:19:07.638 CNTRLR [Node 008] MultilevelSensorCC: doing a partial interview... 12:19:07.638 CNTRLR » [Node 008] querying Air temperature sensor reading... 12:19:07.644 SERIAL « 0x010700130c000002e5 (9 bytes) 12:19:07.645 SERIAL » [ACK] (0x06) 12:19:07.646 DRIVER « [REQ] [SendData] callback id: 12 transmit status: OK 12:19:07.653 SERIAL « 0x010e00040017083202213200000000c9 (16 bytes) 12:19:07.655 CNTRLR [Node 023] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 12:19:07.657 CNTRLR [Node 023] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 12:19:07.658 SERIAL » [ACK] (0x06) 12:19:07.661 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 12:19:07.670 SERIAL » 0x010b0013080431040100250df7 (13 bytes) 12:19:07.671 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 13 └─[MultilevelSensorCCGet] sensor type: Air temperature scale: Celsius 12:19:07.673 CNTRLR [Node 023] [~] [Meter] interviewComplete: true => true [Endpoint 0] [internal] 12:19:07.675 CNTRLR [Node 023] ConfigurationCC: Loading configuration parameters from device confi g 12:19:07.684 CNTRLR [Node 023] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 12:19:07.687 CNTRLR [Node 023] [Configuration] 1: metadata updated 12:19:07.696 CNTRLR [Node 023] [Configuration] 2: metadata updated 12:19:07.698 CNTRLR [Node 023] [Configuration] 3: metadata updated 12:19:07.700 CNTRLR [Node 023] [Configuration] 10: metadata updated 12:19:07.702 CNTRLR [Node 023] [Configuration] 11: metadata updated 12:19:07.704 CNTRLR [Node 023] [Configuration] 12: metadata updated 12:19:07.706 CNTRLR [Node 023] [Configuration] 13: metadata updated 12:19:07.718 CNTRLR [Node 023] [Configuration] 14: metadata updated 12:19:07.720 CNTRLR [Node 023] [Configuration] 15: metadata updated 12:19:07.722 CNTRLR [Node 023] [Configuration] 20: metadata updated 12:19:07.724 CNTRLR [Node 023] [Configuration] 21: metadata updated 12:19:07.725 CNTRLR [Node 023] [Configuration] 22: metadata updated 12:19:07.727 CNTRLR [Node 023] [Configuration] 23: metadata updated 12:19:07.729 CNTRLR [Node 023] [Configuration] 24: metadata updated 12:19:07.730 CNTRLR [Node 023] [Configuration] 30: metadata updated 12:19:07.732 CNTRLR [Node 023] [Configuration] 31: metadata updated 12:19:07.734 CNTRLR [Node 023] [Configuration] 32: metadata updated 12:19:07.735 CNTRLR [Node 023] [Configuration] 40: metadata updated 12:19:07.737 CNTRLR [Node 023] [Configuration] 41: metadata updated 12:19:07.739 CNTRLR [Node 023] [Configuration] 42: metadata updated 12:19:07.740 CNTRLR [Node 023] [Configuration] 43: metadata updated 12:19:07.742 CNTRLR [Node 023] [Configuration] 50: metadata updated 12:19:07.744 CNTRLR [Node 023] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 12:19:07.745 CNTRLR » [Node 023] querying parameter #1 value... 12:19:07.789 SERIAL « [ACK] (0x06) 12:19:07.792 SERIAL « 0x0104011301e8 (6 bytes) 12:19:07.793 SERIAL » [ACK] (0x06) 12:19:07.795 DRIVER « [RES] [SendData] was sent: true 12:19:07.808 SERIAL « 0x010700130d000006e0 (9 bytes) 12:19:07.808 SERIAL » [ACK] (0x06) 12:19:07.810 DRIVER « [REQ] [SendData] callback id: 13 transmit status: OK 12:19:07.819 SERIAL « 0x010c000400080631050122003ad4 (14 bytes) 12:19:07.821 CNTRLR [Node 008] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 12:19:07.823 CNTRLR [Node 008] [~] [Multilevel Sensor] Air temperature: 5.8 => 5.8 [Endpoint 0] 12:19:07.824 SERIAL » [ACK] (0x06) 12:19:07.826 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 5.8 12:19:07.835 SERIAL » 0x010a00131703700501250ead (12 bytes) 12:19:07.836 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 14 └─[ConfigurationCCGet] parameter #: 1 12:19:07.837 CNTRLR « [Node 008] received current Air temperature sensor reading: 5.8 °C 12:19:07.838 CNTRLR [Node 008] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 12:19:07.839 CNTRLR [Node 008] ConfigurationCC: Loading configuration parameters from device confi g 12:19:07.842 CNTRLR [Node 008] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 12:19:07.844 CNTRLR [Node 008] [Configuration] 1: metadata updated 12:19:07.846 CNTRLR [Node 008] [Configuration] 2: metadata updated 12:19:07.847 CNTRLR [Node 008] [Configuration] 3: metadata updated 12:19:07.849 CNTRLR [Node 008] [Configuration] 4: metadata updated 12:19:07.851 CNTRLR [Node 008] [Configuration] 5: metadata updated 12:19:07.852 CNTRLR [Node 008] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 12:19:07.853 CNTRLR » [Node 008] querying parameter #1 value... 12:19:07.883 SERIAL « [ACK] (0x06) 12:19:07.885 SERIAL « 0x0104011301e8 (6 bytes) 12:19:07.886 SERIAL » [ACK] (0x06) 12:19:07.892 DRIVER « [RES] [SendData] was sent: true 12:19:07.905 SERIAL « 0x010700130e000007e2 (9 bytes) 12:19:07.906 SERIAL » [ACK] (0x06) 12:19:07.908 DRIVER « [REQ] [SendData] callback id: 14 transmit status: OK 12:19:07.917 SERIAL « 0x010b0004001705700601010094 (13 bytes) 12:19:07.923 CNTRLR [Node 023] [~] [Configuration] 1: 0 => 0 12:19:07.924 SERIAL » [ACK] (0x06) 12:19:07.926 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 0 12:19:07.932 SERIAL » 0x010a00130803700501250fb3 (12 bytes) 12:19:07.933 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 15 └─[ConfigurationCCGet] parameter #: 1 12:19:07.934 CNTRLR « [Node 023] parameter #1 has value: 0 12:19:07.935 CNTRLR » [Node 023] querying parameter #2 value... 12:19:07.942 SERIAL « [ACK] (0x06) 12:19:07.944 SERIAL « 0x0104011301e8 (6 bytes) 12:19:07.944 SERIAL » [ACK] (0x06) 12:19:07.945 DRIVER « [RES] [SendData] was sent: true 12:19:07.995 SERIAL « 0x010700130f000006e2 (9 bytes) 12:19:07.996 SERIAL » [ACK] (0x06) 12:19:07.996 DRIVER « [REQ] [SendData] callback id: 15 transmit status: OK 12:19:08.079 SERIAL « 0x010b0004000805700601010289 (13 bytes) 12:19:08.082 CNTRLR [Node 008] [~] [Configuration] 1: 2 => 2 12:19:08.083 SERIAL » [ACK] (0x06) 12:19:08.084 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 2 12:19:08.100 SERIAL » 0x010a001317037005022510b0 (12 bytes) 12:19:08.101 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 16 └─[ConfigurationCCGet] parameter #: 2 12:19:08.102 CNTRLR « [Node 008] parameter #1 has value: 2 12:19:08.102 CNTRLR » [Node 008] querying parameter #2 value... 12:19:08.113 SERIAL « [ACK] (0x06) 12:19:08.115 SERIAL « 0x0104011301e8 (6 bytes) 12:19:08.116 SERIAL » [ACK] (0x06) 12:19:08.118 DRIVER « [RES] [SendData] was sent: true 12:19:08.170 SERIAL « 0x0107001310000006fd (9 bytes) 12:19:08.171 SERIAL » [ACK] (0x06) 12:19:08.172 DRIVER « [REQ] [SendData] callback id: 16 transmit status: OK 12:19:08.178 SERIAL « 0x010b0004001705700602010196 (13 bytes) 12:19:08.183 CNTRLR [Node 023] [~] [Configuration] 2: 1 => 1 12:19:08.185 SERIAL » [ACK] (0x06) 12:19:08.186 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 1 12:19:08.192 SERIAL » 0x010a001308037005022511ae (12 bytes) 12:19:08.192 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 17 └─[ConfigurationCCGet] parameter #: 2 12:19:08.193 CNTRLR « [Node 023] parameter #2 has value: 1 12:19:08.194 CNTRLR » [Node 023] querying parameter #3 value... 12:19:08.199 SERIAL « [ACK] (0x06) 12:19:08.205 SERIAL « 0x0104011301e8 (6 bytes) 12:19:08.206 SERIAL » [ACK] (0x06) 12:19:08.208 DRIVER « [RES] [SendData] was sent: true 12:19:08.254 SERIAL « 0x0107001311000006fc (9 bytes) 12:19:08.255 SERIAL » [ACK] (0x06) 12:19:08.256 DRIVER « [REQ] [SendData] callback id: 17 transmit status: OK 12:19:08.328 SERIAL « 0x010b0004000805700602010088 (13 bytes) 12:19:08.332 CNTRLR [Node 008] [~] [Configuration] 2: 0 => 0 12:19:08.333 SERIAL » [ACK] (0x06) 12:19:08.336 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 0 12:19:08.341 SERIAL » 0x010a001317037005032512b3 (12 bytes) 12:19:08.342 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 18 └─[ConfigurationCCGet] parameter #: 3 12:19:08.342 CNTRLR « [Node 008] parameter #2 has value: 0 12:19:08.343 CNTRLR » [Node 008] querying parameter #3 value... 12:19:08.355 SERIAL « [ACK] (0x06) 12:19:08.357 SERIAL « 0x0104011301e8 (6 bytes) 12:19:08.357 SERIAL » [ACK] (0x06) 12:19:08.360 DRIVER « [RES] [SendData] was sent: true 12:19:08.425 SERIAL « 0x0107001312000008f1 (9 bytes) 12:19:08.426 SERIAL » [ACK] (0x06) 12:19:08.427 DRIVER « [REQ] [SendData] callback id: 18 transmit status: OK 12:19:08.437 SERIAL « 0x010c000400170670060302000091 (14 bytes) 12:19:08.441 CNTRLR [Node 023] [~] [Configuration] 3: 0 => 0 12:19:08.442 SERIAL » [ACK] (0x06) 12:19:08.444 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 2 value: 0 12:19:08.450 SERIAL » 0x010a001308037005032513ad (12 bytes) 12:19:08.451 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 19 └─[ConfigurationCCGet] parameter #: 3 12:19:08.452 CNTRLR « [Node 023] parameter #3 has value: 0 12:19:08.452 CNTRLR » [Node 023] querying parameter #10 value... 12:19:08.457 SERIAL « [ACK] (0x06) 12:19:08.460 SERIAL « 0x0104011301e8 (6 bytes) 12:19:08.461 SERIAL » [ACK] (0x06) 12:19:08.462 DRIVER « [RES] [SendData] was sent: true 12:19:08.516 SERIAL « 0x0107001313000006fe (9 bytes) 12:19:08.516 SERIAL » [ACK] (0x06) 12:19:08.520 DRIVER « [REQ] [SendData] callback id: 19 transmit status: OK 12:19:08.599 SERIAL « 0x010b0004000805700603010188 (13 bytes) 12:19:08.605 CNTRLR [Node 008] [~] [Configuration] 3: 1 => 1 12:19:08.606 SERIAL » [ACK] (0x06) 12:19:08.608 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 1 12:19:08.632 SERIAL » 0x010a0013170370050a2514bc (12 bytes) 12:19:08.633 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 20 └─[ConfigurationCCGet] parameter #: 10 12:19:08.634 CNTRLR « [Node 008] parameter #3 has value: 1 12:19:08.634 CNTRLR » [Node 008] querying parameter #4 value... 12:19:08.643 SERIAL « [ACK] (0x06) 12:19:08.646 SERIAL « 0x0104011301e8 (6 bytes) 12:19:08.648 SERIAL » [ACK] (0x06) 12:19:08.650 DRIVER « [RES] [SendData] was sent: true 12:19:08.686 SERIAL « 0x0107001314000005fa (9 bytes) 12:19:08.688 SERIAL » [ACK] (0x06) 12:19:08.690 DRIVER « [REQ] [SendData] callback id: 20 transmit status: OK 12:19:08.703 SERIAL « 0x010b000400170570060a0150cf (13 bytes) 12:19:08.709 CNTRLR [Node 023] [~] [Configuration] 10: 80 => 80 12:19:08.711 SERIAL » [ACK] (0x06) 12:19:08.713 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 80 12:19:08.724 SERIAL » 0x010a001308037005042515ac (12 bytes) 12:19:08.725 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 21 └─[ConfigurationCCGet] parameter #: 4 12:19:08.726 CNTRLR « [Node 023] parameter #10 has value: 80 12:19:08.727 CNTRLR » [Node 023] querying parameter #11 value... 12:19:08.734 SERIAL « [ACK] (0x06) 12:19:08.737 SERIAL « 0x0104011301e8 (6 bytes) 12:19:08.738 SERIAL » [ACK] (0x06) 12:19:08.741 DRIVER « [RES] [SendData] was sent: true 12:19:08.788 SERIAL « 0x0107001315000006f8 (9 bytes) 12:19:08.788 SERIAL » [ACK] (0x06) 12:19:08.790 DRIVER « [REQ] [SendData] callback id: 21 transmit status: OK 12:19:08.870 SERIAL « 0x010c000400080670060402000f86 (14 bytes) 12:19:08.874 CNTRLR [Node 008] [~] [Configuration] 4: 15 => 15 12:19:08.875 SERIAL » [ACK] (0x06) 12:19:08.876 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 2 value: 15 12:19:08.882 SERIAL » 0x010a0013170370050b2516bf (12 bytes) 12:19:08.882 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 22 └─[ConfigurationCCGet] parameter #: 11 12:19:08.884 CNTRLR « [Node 008] parameter #4 has value: 15 12:19:08.884 CNTRLR » [Node 008] querying parameter #5 value... 12:19:08.889 SERIAL « [ACK] (0x06) 12:19:08.891 SERIAL « 0x0104011301e8 (6 bytes) 12:19:08.893 SERIAL » [ACK] (0x06) 12:19:08.894 DRIVER « [RES] [SendData] was sent: true 12:19:08.965 SERIAL « 0x0107001316000008f5 (9 bytes) 12:19:08.965 SERIAL » [ACK] (0x06) 12:19:08.966 DRIVER « [REQ] [SendData] callback id: 22 transmit status: OK 12:19:08.976 SERIAL « 0x010b000400170570060b010f91 (13 bytes) 12:19:08.980 CNTRLR [Node 023] [~] [Configuration] 11: 15 => 15 12:19:08.981 SERIAL » [ACK] (0x06) 12:19:08.984 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 11 value size: 1 value: 15 12:19:08.992 SERIAL » 0x010a001308037005052517af (12 bytes) 12:19:08.993 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 23 └─[ConfigurationCCGet] parameter #: 5 12:19:08.993 CNTRLR « [Node 023] parameter #11 has value: 15 12:19:08.994 CNTRLR » [Node 023] querying parameter #12 value... 12:19:08.997 SERIAL « [ACK] (0x06) 12:19:09.003 SERIAL « 0x0104011301e8 (6 bytes) 12:19:09.007 SERIAL » [ACK] (0x06) 12:19:09.009 DRIVER « [RES] [SendData] was sent: true 12:19:09.055 SERIAL « 0x0107001317000006fa (9 bytes) 12:19:09.055 SERIAL » [ACK] (0x06) 12:19:09.056 DRIVER « [REQ] [SendData] callback id: 23 transmit status: OK 12:19:09.141 SERIAL « 0x010b000400080570060501028d (13 bytes) 12:19:09.145 CNTRLR [Node 008] [~] [Configuration] 5: 2 => 2 12:19:09.146 SERIAL » [ACK] (0x06) 12:19:09.148 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 1 value: 2 12:19:09.160 SERIAL » 0x010a0013170370050c2518b6 (12 bytes) 12:19:09.161 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 24 └─[ConfigurationCCGet] parameter #: 12 12:19:09.161 CNTRLR « [Node 008] parameter #5 has value: 2 12:19:09.162 CNTRLR [Node 008] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 12:19:09.176 SERIAL « [ACK] (0x06) 12:19:09.178 SERIAL « 0x0104011301e8 (6 bytes) 12:19:09.178 SERIAL » [ACK] (0x06) 12:19:09.180 DRIVER « [RES] [SendData] was sent: true 12:19:09.186 CNTRLR [Node 008] AssociationCC: doing a partial interview... 12:19:09.187 CNTRLR » [Node 008] querying association group #1... 12:19:09.225 SERIAL « 0x0107001318000006f5 (9 bytes) 12:19:09.226 SERIAL » [ACK] (0x06) 12:19:09.227 DRIVER « [REQ] [SendData] callback id: 24 transmit status: OK 12:19:09.237 SERIAL « 0x010c000400170670060c02001e80 (14 bytes) 12:19:09.240 CNTRLR [Node 023] [~] [Configuration] 12: 30 => 30 12:19:09.242 SERIAL » [ACK] (0x06) 12:19:09.243 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 30 12:19:09.249 SERIAL » 0x010a00130803850201251957 (12 bytes) 12:19:09.250 DRIVER » [Node 008] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 25 └─[AssociationCCGet] group id: 1 12:19:09.251 CNTRLR « [Node 023] parameter #12 has value: 30 12:19:09.251 CNTRLR » [Node 023] querying parameter #13 value... 12:19:09.255 SERIAL « [ACK] (0x06) 12:19:09.260 SERIAL « 0x0104011301e8 (6 bytes) 12:19:09.260 SERIAL » [ACK] (0x06) 12:19:09.261 DRIVER « [RES] [SendData] was sent: true 12:19:09.313 SERIAL « 0x0107001319000006f4 (9 bytes) 12:19:09.313 SERIAL » [ACK] (0x06) 12:19:09.314 DRIVER « [REQ] [SendData] callback id: 25 transmit status: OK 12:19:09.399 SERIAL « 0x010c00040008068503010a000175 (14 bytes) 12:19:09.401 SERIAL » [ACK] (0x06) 12:19:09.403 CNTRLR [Node 008] [~] [Association] maxNodes[1]: 10 => 10 [internal] 12:19:09.404 CNTRLR [Node 008] [~] [Association] nodeIds[1]: 1 => 1 [internal] 12:19:09.405 DRIVER « [Node 008] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 1 max # of nodes: 10 node IDs: 1 reports to follow: 0 12:19:09.412 SERIAL » 0x010a0013170370050d251ab5 (12 bytes) 12:19:09.413 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 26 └─[ConfigurationCCGet] parameter #: 13 12:19:09.414 CNTRLR « [Node 008] received information for association group #1: maximum # of nodes: 10 currently assigned nodes: 1 12:19:09.415 CNTRLR [Node 008] [~] [Association] hasLifeline: true => true [internal] 12:19:09.416 CNTRLR [Node 008] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 12:19:09.431 SERIAL « [ACK] (0x06) 12:19:09.435 SERIAL « 0x0104011301e8 (6 bytes) 12:19:09.436 SERIAL » [ACK] (0x06) 12:19:09.438 DRIVER « [RES] [SendData] was sent: true 12:19:09.444 CNTRLR [Node 008] AssociationGroupInfoCC: doing a partial interview... 12:19:09.445 CNTRLR [Node 008] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 12:19:09.448 CNTRLR [Node 008] NotificationCC: doing a partial interview... 12:19:09.451 CNTRLR [Node 008] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 12:19:09.451 CNTRLR [Node 008] Interview stage completed: CommandClasses 12:19:09.452 CNTRLR [Node 008] Interview stage completed: OverwriteConfig 12:19:09.452 CNTRLR » [Node 008] requesting node neighbors... 12:19:09.495 SERIAL « 0x010700131a000008f9 (9 bytes) 12:19:09.496 SERIAL » [ACK] (0x06) 12:19:09.497 DRIVER « [REQ] [SendData] callback id: 26 transmit status: OK 12:19:09.507 SERIAL « 0x010c000400170670060d02000a95 (14 bytes) 12:19:09.514 CNTRLR [Node 023] [~] [Configuration] 13: 10 => 10 12:19:09.515 SERIAL » [ACK] (0x06) 12:19:09.517 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 2 value: 10 12:19:09.523 SERIAL » 0x010700800800000070 (9 bytes) 12:19:09.524 DRIVER » [Node 008] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 12:19:09.525 CNTRLR « [Node 023] parameter #13 has value: 10 12:19:09.525 CNTRLR » [Node 023] querying parameter #14 value... 12:19:09.530 SERIAL « [ACK] (0x06) 12:19:09.532 SERIAL « 0x012001800100d0253800000000000000000000000000000000000000000000000 (34 bytes) 092 12:19:09.533 SERIAL » [ACK] (0x06) 12:19:09.534 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 21, 23, 24, 25, 27, 30, 36, 37, 38 12:19:09.549 SERIAL » 0x010a0013170370050e251bb7 (12 bytes) 12:19:09.550 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 27 └─[ConfigurationCCGet] parameter #: 14 12:19:09.550 CNTRLR « [Node 008] node neighbors received: 1, 21, 23, 24, 25, 27, 30, 36, 37, 38 12:19:09.551 CNTRLR [Node 008] Interview stage completed: Neighbors 12:19:09.551 CNTRLR [Node 008] Interview completed 12:19:09.556 SERIAL « [ACK] (0x06) 12:19:09.559 SERIAL « 0x0104011301e8 (6 bytes) 12:19:09.560 SERIAL » [ACK] (0x06) 12:19:09.562 DRIVER « [RES] [SendData] was sent: true 12:19:09.574 SERIAL « 0x010700131b000002f2 (9 bytes) 12:19:09.575 SERIAL » [ACK] (0x06) 12:19:09.576 DRIVER « [REQ] [SendData] callback id: 27 transmit status: OK 12:19:09.586 SERIAL « 0x010c000400170670060e020e1082 (14 bytes) 12:19:09.590 CNTRLR [Node 023] [~] [Configuration] 14: 3600 => 3600 12:19:09.590 SERIAL » [ACK] (0x06) 12:19:09.592 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 2 value: 3600 12:19:09.596 SERIAL » 0x01080013190100251cc5 (10 bytes) 12:19:09.597 DRIVER » [Node 025] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 28 └─[NoOperationCC] 12:19:09.597 CNTRLR « [Node 023] parameter #14 has value: 3600 12:19:09.598 CNTRLR » [Node 023] querying parameter #15 value... 12:19:09.612 SERIAL « [ACK] (0x06) 12:19:09.618 SERIAL « 0x0104011301e8 (6 bytes) 12:19:09.620 SERIAL » [ACK] (0x06) 12:19:09.622 DRIVER « [RES] [SendData] was sent: true 12:19:16.293 SERIAL « 0x010700131c01029e6a (9 bytes) 12:19:16.294 SERIAL » [ACK] (0x06) 12:19:16.296 DRIVER « [REQ] [SendData] callback id: 28 transmit status: NoAck 12:19:16.330 SERIAL » 0x010a0013170370050f251db0 (12 bytes) 12:19:16.332 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 29 └─[ConfigurationCCGet] parameter #: 15 12:19:16.333 CNTRLR [Node 025] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 12:19:16.334 CNTRLR [Node 025] The node is asleep. 12:19:16.340 CNTRLR [Node 025] The node is ready to be used 12:19:16.342 CNTRLR [Node 025] ping failed: Failed to send the command after 1 attempts (Status No Ack) 12:19:16.352 CNTRLR [Node 025] ManufacturerSpecificCC: doing a partial interview... 12:19:16.353 CNTRLR [Node 025] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 12:19:16.376 SERIAL « [ACK] (0x06) 12:19:16.380 SERIAL « 0x0104011301e8 (6 bytes) 12:19:16.380 SERIAL » [ACK] (0x06) 12:19:16.386 DRIVER « [RES] [SendData] was sent: true 12:19:16.400 CNTRLR [Node 025] VersionCC: doing a partial interview... 12:19:16.401 CNTRLR [Node 025] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:19:16.402 CNTRLR [Node 025] trying to load device config 12:19:16.406 SERIAL « 0x010700131d000002f4 (9 bytes) 12:19:16.407 SERIAL » [ACK] (0x06) 12:19:16.412 DRIVER « [REQ] [SendData] callback id: 29 transmit status: OK 12:19:16.432 SERIAL « 0x010b000400170570060f01009a (13 bytes) 12:19:16.441 CNTRLR [Node 023] [~] [Configuration] 15: 0 => 0 12:19:16.442 SERIAL » [ACK] (0x06) 12:19:16.450 CNTRLR [Node 025] device config loaded 12:19:16.451 CNTRLR [Node 025] ZWavePlusCC: doing a partial interview... 12:19:16.451 CNTRLR [Node 025] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 12:19:16.452 CNTRLR [Node 025] BatteryCC: doing a partial interview... 12:19:16.452 CNTRLR » [Node 025] querying battery status... 12:19:16.457 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 15 value size: 1 value: 0 12:19:16.462 SERIAL » 0x010800131b0100251ec5 (10 bytes) 12:19:16.463 DRIVER » [Node 027] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 30 └─[NoOperationCC] 12:19:16.464 CNTRLR « [Node 023] parameter #15 has value: 0 12:19:16.464 CNTRLR » [Node 023] querying parameter #20 value... 12:19:16.468 SERIAL « [ACK] (0x06) 12:19:16.473 SERIAL « 0x0104011301e8 (6 bytes) 12:19:16.473 SERIAL » [ACK] (0x06) 12:19:16.477 DRIVER « [RES] [SendData] was sent: true 12:19:23.065 SERIAL « 0x010700131e01029462 (9 bytes) 12:19:23.065 SERIAL » [ACK] (0x06) 12:19:23.066 DRIVER « [REQ] [SendData] callback id: 30 transmit status: NoAck 12:19:23.074 SERIAL » 0x010800131d0100251fc2 (10 bytes) 12:19:23.074 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 31 └─[NoOperationCC] 12:19:23.075 CNTRLR [Node 027] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 12:19:23.075 CNTRLR [Node 027] The node is asleep. 12:19:23.077 CNTRLR [Node 027] The node is ready to be used 12:19:23.078 CNTRLR [Node 027] ping failed: Failed to send the command after 1 attempts (Status No Ack) 12:19:23.080 CNTRLR [Node 027] ManufacturerSpecificCC: doing a partial interview... 12:19:23.080 CNTRLR [Node 027] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 12:19:23.091 SERIAL « [ACK] (0x06) 12:19:23.094 SERIAL « 0x0104011301e8 (6 bytes) 12:19:23.094 SERIAL » [ACK] (0x06) 12:19:23.095 DRIVER « [RES] [SendData] was sent: true 12:19:23.101 CNTRLR [Node 027] VersionCC: doing a partial interview... 12:19:23.101 CNTRLR [Node 027] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:19:23.102 CNTRLR [Node 027] trying to load device config 12:19:23.111 CNTRLR [Node 027] device config loaded 12:19:23.113 CNTRLR » [Node 027] querying device endpoint information... 12:19:23.133 SERIAL « 0x010700131f000005f1 (9 bytes) 12:19:23.133 SERIAL » [ACK] (0x06) 12:19:23.136 DRIVER « [REQ] [SendData] callback id: 31 transmit status: OK 12:19:23.143 SERIAL » 0x010a00131703700514252096 (12 bytes) 12:19:23.143 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 32 └─[ConfigurationCCGet] parameter #: 20 12:19:23.144 CNTRLR « [Node 029] ping successful 12:19:23.146 CNTRLR [Node 029] ManufacturerSpecificCC: doing a partial interview... 12:19:23.146 CNTRLR [Node 029] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 12:19:23.146 CNTRLR [Node 029] VersionCC: doing a partial interview... 12:19:23.147 CNTRLR [Node 029] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:19:23.147 CNTRLR [Node 029] trying to load device config 12:19:23.265 SERIAL « [ACK] (0x06) 12:19:23.267 SERIAL « 0x0104011301e8 (6 bytes) 12:19:23.267 SERIAL » [ACK] (0x06) 12:19:23.270 DRIVER « [RES] [SendData] was sent: true 12:19:23.305 CNTRLR [Node 029] device config loaded 12:19:23.306 CNTRLR [Node 029] BatteryCC: doing a partial interview... 12:19:23.306 CNTRLR » [Node 029] querying battery status... 12:19:23.310 SERIAL « 0x0107001320000002c9 (9 bytes) 12:19:23.310 SERIAL » [ACK] (0x06) 12:19:23.312 DRIVER « [REQ] [SendData] callback id: 32 transmit status: OK 12:19:23.319 SERIAL « 0x010b0004001705700614010081 (13 bytes) 12:19:23.322 CNTRLR [Node 023] [~] [Configuration] 20: 0 => 0 12:19:23.323 SERIAL » [ACK] (0x06) 12:19:23.325 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 0 12:19:23.330 SERIAL » 0x010900131d02800225217c (11 bytes) 12:19:23.331 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 33 └─[BatteryCCGet] 12:19:23.332 CNTRLR « [Node 023] parameter #20 has value: 0 12:19:23.332 CNTRLR » [Node 023] querying parameter #21 value... 12:19:23.339 SERIAL « [ACK] (0x06) 12:19:23.341 SERIAL « 0x0104011301e8 (6 bytes) 12:19:23.342 SERIAL » [ACK] (0x06) 12:19:23.345 DRIVER « [RES] [SendData] was sent: true 12:19:23.385 SERIAL « 0x0107001321000005cf (9 bytes) 12:19:23.386 SERIAL » [ACK] (0x06) 12:19:23.387 DRIVER « [REQ] [SendData] callback id: 33 transmit status: OK 12:19:23.438 SERIAL « 0x01090004001d038003640b (11 bytes) 12:19:23.445 CNTRLR [Node 029] [~] [Battery] level: 100 => 100 [Endpoint 0] 12:19:23.447 CNTRLR [Node 029] [~] [Battery] isLow: false => false [Endpoint 0] 12:19:23.447 SERIAL » [ACK] (0x06) 12:19:23.449 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 12:19:23.456 SERIAL » 0x010a00131703700515252295 (12 bytes) 12:19:23.457 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 34 └─[ConfigurationCCGet] parameter #: 21 12:19:23.458 CNTRLR [Node 029] The node is alive. 12:19:23.459 CNTRLR [Node 029] The node is ready to be used 12:19:23.462 CNTRLR « [Node 029] received response for battery information: level: 100 12:19:23.462 CNTRLR [Node 029] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:19:23.477 SERIAL « [ACK] (0x06) 12:19:23.482 SERIAL « 0x0104011301e8 (6 bytes) 12:19:23.482 SERIAL » [ACK] (0x06) 12:19:23.485 DRIVER « [RES] [SendData] was sent: true 12:19:23.491 CNTRLR [Node 029] AssociationCC: doing a partial interview... 12:19:23.491 CNTRLR [Node 029] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 12:19:23.492 CNTRLR [Node 029] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 12:19:23.494 CNTRLR [Node 029] TimeParametersCC: doing a partial interview... 12:19:23.494 CNTRLR » [Node 029] setting current time... 12:19:23.525 SERIAL « 0x0107001322000006cf (9 bytes) 12:19:23.526 SERIAL » [ACK] (0x06) 12:19:23.527 DRIVER « [REQ] [SendData] callback id: 34 transmit status: OK 12:19:23.637 SERIAL « 0x010c000400170670061502012caa (14 bytes) 12:19:23.641 CNTRLR [Node 023] [~] [Configuration] 21: 300 => 300 12:19:23.642 SERIAL » [ACK] (0x06) 12:19:23.644 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 21 value size: 2 value: 300 12:19:23.650 SERIAL » 0x011000131d098b0107e40b0a0c131725238e (18 bytes) 12:19:23.654 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 35 └─[TimeParametersCCSet] date and time: 2020-11-10 12:19:23 12:19:23.654 CNTRLR « [Node 023] parameter #21 has value: 300 12:19:23.654 CNTRLR » [Node 023] querying parameter #22 value... 12:19:23.663 SERIAL « [ACK] (0x06) 12:19:23.664 SERIAL « 0x0104011301e8 (6 bytes) 12:19:23.665 SERIAL » [ACK] (0x06) 12:19:23.666 DRIVER « [RES] [SendData] was sent: true 12:19:23.712 SERIAL « 0x0107001323000006ce (9 bytes) 12:19:23.713 SERIAL » [ACK] (0x06) 12:19:23.714 DRIVER « [REQ] [SendData] callback id: 35 transmit status: OK 12:19:23.720 SERIAL » 0x010a00131703700516252490 (12 bytes) 12:19:23.721 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 36 └─[ConfigurationCCGet] parameter #: 22 12:19:23.722 CNTRLR [Node 029] [~] [Time Parameters] interviewComplete: tr [Endpoint 0] [internal] ue => true 12:19:23.733 SERIAL « [ACK] (0x06) 12:19:23.736 SERIAL « 0x0104011301e8 (6 bytes) 12:19:23.736 SERIAL » [ACK] (0x06) 12:19:23.738 DRIVER « [RES] [SendData] was sent: true 12:19:23.742 CNTRLR [Node 029] BasicCC: doing a partial interview... 12:19:23.743 CNTRLR » [Node 029] querying Basic CC state... 12:19:23.751 SERIAL « 0x0107001324000002cd (9 bytes) 12:19:23.751 SERIAL » [ACK] (0x06) 12:19:23.752 DRIVER « [REQ] [SendData] callback id: 36 transmit status: OK 12:19:23.757 SERIAL « 0x010c00040017067006160201f471 (14 bytes) 12:19:23.761 CNTRLR [Node 023] [~] [Configuration] 22: 500 => 500 12:19:23.762 SERIAL » [ACK] (0x06) 12:19:23.763 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 22 value size: 2 value: 500 12:19:23.773 SERIAL » 0x010900131d0220022525d8 (11 bytes) 12:19:23.774 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 37 └─[BasicCCGet] 12:19:23.775 CNTRLR « [Node 023] parameter #22 has value: 500 12:19:23.775 CNTRLR » [Node 023] querying parameter #23 value... 12:19:23.781 SERIAL « [ACK] (0x06) 12:19:23.783 SERIAL « 0x0104011301e8 (6 bytes) 12:19:23.785 SERIAL » [ACK] (0x06) 12:19:23.786 DRIVER « [RES] [SendData] was sent: true 12:19:23.828 SERIAL « 0x0107001325000005cb (9 bytes) 12:19:23.828 SERIAL » [ACK] (0x06) 12:19:23.829 DRIVER « [REQ] [SendData] callback id: 37 transmit status: OK 12:19:23.880 SERIAL « 0x01090004001d03200300cf (11 bytes) 12:19:23.882 SERIAL » [ACK] (0x06) 12:19:23.885 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[BasicCCReport] current value: 0 12:19:23.890 SERIAL » 0x010a00131703700517252693 (12 bytes) 12:19:23.891 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 38 └─[ConfigurationCCGet] parameter #: 23 12:19:23.892 CNTRLR « [Node 029] received Basic CC state: current value: 0 12:19:23.892 CNTRLR [Node 029] [~] [Basic] interviewComplete: true => true [Endpoint 0] [internal] 12:19:23.903 SERIAL « [ACK] (0x06) 12:19:23.906 SERIAL « 0x0104011301e8 (6 bytes) 12:19:23.906 SERIAL » [ACK] (0x06) 12:19:23.909 DRIVER « [RES] [SendData] was sent: true 12:19:23.912 CNTRLR [Node 029] MultilevelSensorCC: doing a partial interview... 12:19:23.914 CNTRLR » [Node 029] querying current sensor reading... 12:19:23.975 SERIAL « 0x0107001326000008c5 (9 bytes) 12:19:23.976 SERIAL » [ACK] (0x06) 12:19:23.977 DRIVER « [REQ] [SendData] callback id: 38 transmit status: OK 12:19:24.011 SERIAL « 0x010b0004001705700617010684 (13 bytes) 12:19:24.016 CNTRLR [Node 023] [~] [Configuration] 23: 6 => 6 12:19:24.017 SERIAL » [ACK] (0x06) 12:19:24.021 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 23 value size: 1 value: 6 12:19:24.028 SERIAL » 0x010900131d0231042527cd (11 bytes) 12:19:24.029 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 39 └─[MultilevelSensorCCGet] 12:19:24.030 CNTRLR « [Node 023] parameter #23 has value: 6 12:19:24.031 CNTRLR » [Node 023] querying parameter #24 value... 12:19:24.038 SERIAL « [ACK] (0x06) 12:19:24.043 SERIAL « 0x0104011301e8 (6 bytes) 12:19:24.044 SERIAL » [ACK] (0x06) 12:19:24.047 DRIVER « [RES] [SendData] was sent: true 12:19:24.084 SERIAL « 0x0107001327000005c9 (9 bytes) 12:19:24.085 SERIAL » [ACK] (0x06) 12:19:24.085 DRIVER « [REQ] [SendData] callback id: 39 transmit status: OK 12:19:24.139 SERIAL « 0x010c0004001d063105012200ee15 (14 bytes) 12:19:24.143 CNTRLR [Node 029] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 12:19:24.144 CNTRLR [Node 029] [~] [Multilevel Sensor] Air temperature: 26.1 => 23.8 [Endpoint 0] 12:19:24.145 SERIAL » [ACK] (0x06) 12:19:24.146 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 23.8 12:19:24.163 SERIAL » 0x010a00131703700518252892 (12 bytes) 12:19:24.164 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 40 └─[ConfigurationCCGet] parameter #: 24 12:19:24.165 CNTRLR « [Node 029] received current sensor reading: sensor type: Air temperature value: 23.8 °C 12:19:24.166 CNTRLR [Node 029] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 12:19:24.181 SERIAL « [ACK] (0x06) 12:19:24.186 SERIAL « 0x0104011301e8 (6 bytes) 12:19:24.187 SERIAL » [ACK] (0x06) 12:19:24.189 DRIVER « [RES] [SendData] was sent: true 12:19:24.193 CNTRLR [Node 029] ConfigurationCC: Loading configuration parameters from device confi g 12:19:24.196 CNTRLR [Node 029] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 12:19:24.198 CNTRLR [Node 029] [Configuration] 1: metadata updated 12:19:24.199 CNTRLR [Node 029] [Configuration] 2: metadata updated 12:19:24.201 CNTRLR [Node 029] [Configuration] 5: metadata updated 12:19:24.203 CNTRLR [Node 029] [Configuration] 7: metadata updated 12:19:24.205 CNTRLR [Node 029] [Configuration] 10: metadata updated 12:19:24.207 CNTRLR [Node 029] [Configuration] 12: metadata updated 12:19:24.209 CNTRLR [Node 029] [Configuration] 13: metadata updated 12:19:24.211 CNTRLR [Node 029] [Configuration] 73: metadata updated 12:19:24.212 CNTRLR [Node 029] [Configuration] 80: metadata updated 12:19:24.214 CNTRLR [Node 029] [Configuration] 81: metadata updated 12:19:24.215 CNTRLR [Node 029] [Configuration] 82: metadata updated 12:19:24.217 CNTRLR [Node 029] [Configuration] 83: metadata updated 12:19:24.218 CNTRLR [Node 029] [Configuration] 84: metadata updated 12:19:24.220 CNTRLR [Node 029] [Configuration] 85: metadata updated 12:19:24.221 CNTRLR [Node 029] [Configuration] 86: metadata updated 12:19:24.222 CNTRLR [Node 029] [Configuration] 87: metadata updated 12:19:24.223 CNTRLR [Node 029] [Configuration] 88: metadata updated 12:19:24.224 CNTRLR [Node 029] [Configuration] 89: metadata updated 12:19:24.226 CNTRLR [Node 029] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 12:19:24.226 CNTRLR » [Node 029] querying parameter #1 value... 12:19:24.233 SERIAL « 0x0107001328000006c5 (9 bytes) 12:19:24.233 SERIAL » [ACK] (0x06) 12:19:24.236 DRIVER « [REQ] [SendData] callback id: 40 transmit status: OK 12:19:24.241 SERIAL « 0x010c00040017067006180200ff75 (14 bytes) 12:19:24.246 CNTRLR [Node 023] [~] [Configuration] 24: 255 => 255 12:19:24.247 SERIAL » [ACK] (0x06) 12:19:24.260 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 24 value size: 2 value: 255 12:19:24.270 SERIAL » 0x010a00131d03700501252980 (12 bytes) 12:19:24.271 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 41 └─[ConfigurationCCGet] parameter #: 1 12:19:24.272 CNTRLR « [Node 023] parameter #24 has value: 255 12:19:24.272 CNTRLR » [Node 023] querying parameter #30 value... 12:19:24.284 SERIAL « [ACK] (0x06) 12:19:24.287 SERIAL « 0x0104011301e8 (6 bytes) 12:19:24.288 SERIAL » [ACK] (0x06) 12:19:24.291 DRIVER « [RES] [SendData] was sent: true 12:19:24.326 SERIAL « 0x0107001329000005c7 (9 bytes) 12:19:24.327 SERIAL » [ACK] (0x06) 12:19:24.327 DRIVER « [REQ] [SendData] callback id: 41 transmit status: OK 12:19:24.381 SERIAL « 0x010c0004001d0670060102000099 (14 bytes) 12:19:24.384 CNTRLR [Node 029] [~] [Configuration] 1: 0 => 0 12:19:24.385 SERIAL » [ACK] (0x06) 12:19:24.387 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 2 value: 0 12:19:24.392 SERIAL » 0x010a0013170370051e252a96 (12 bytes) 12:19:24.393 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 42 └─[ConfigurationCCGet] parameter #: 30 12:19:24.394 CNTRLR « [Node 029] parameter #1 has value: 0 12:19:24.394 CNTRLR » [Node 029] querying parameter #2 value... 12:19:24.400 SERIAL « [ACK] (0x06) 12:19:24.403 SERIAL « 0x0104011301e8 (6 bytes) 12:19:24.404 SERIAL » [ACK] (0x06) 12:19:24.406 DRIVER « [RES] [SendData] was sent: true 12:19:24.475 SERIAL « 0x010700132a000008c9 (9 bytes) 12:19:24.475 SERIAL » [ACK] (0x06) 12:19:24.476 DRIVER « [REQ] [SendData] callback id: 42 transmit status: OK 12:19:24.488 SERIAL « 0x010b000400170570061e013fb4 (13 bytes) 12:19:24.492 CNTRLR [Node 023] [~] [Configuration] 30: 63 => 63 12:19:24.493 SERIAL » [ACK] (0x06) 12:19:24.494 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 63 12:19:24.499 SERIAL » 0x010a00131d03700502252b81 (12 bytes) 12:19:24.506 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 43 └─[ConfigurationCCGet] parameter #: 2 12:19:24.507 CNTRLR « [Node 023] parameter #30 has value: 63 12:19:24.507 CNTRLR » [Node 023] querying parameter #31 value... 12:19:24.513 SERIAL « [ACK] (0x06) 12:19:24.516 SERIAL « 0x0104011301e8 (6 bytes) 12:19:24.517 SERIAL » [ACK] (0x06) 12:19:24.519 DRIVER « [RES] [SendData] was sent: true 12:19:24.562 SERIAL « 0x010700132b000006c6 (9 bytes) 12:19:24.562 SERIAL » [ACK] (0x06) 12:19:24.564 DRIVER « [REQ] [SendData] callback id: 43 transmit status: OK 12:19:24.613 SERIAL « 0x010b0004001d0570060201039e (13 bytes) 12:19:24.621 CNTRLR [Node 029] [~] [Configuration] 2: 3 => 3 12:19:24.623 SERIAL » [ACK] (0x06) 12:19:24.627 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 3 12:19:24.639 SERIAL » 0x010a0013170370051f252c91 (12 bytes) 12:19:24.640 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 44 └─[ConfigurationCCGet] parameter #: 31 12:19:24.641 CNTRLR « [Node 029] parameter #2 has value: 3 12:19:24.641 CNTRLR » [Node 029] querying parameter #5 value... 12:19:24.646 SERIAL « [ACK] (0x06) 12:19:24.649 SERIAL « 0x0104011301e8 (6 bytes) 12:19:24.650 SERIAL » [ACK] (0x06) 12:19:24.651 DRIVER « [RES] [SendData] was sent: true 12:19:24.705 SERIAL « 0x010700132c000006c1 (9 bytes) 12:19:24.706 SERIAL » [ACK] (0x06) 12:19:24.707 DRIVER « [REQ] [SendData] callback id: 44 transmit status: OK 12:19:24.717 SERIAL « 0x010b000400170570061f01008a (13 bytes) 12:19:24.720 CNTRLR [Node 023] [~] [Configuration] 31: 0 => 0 12:19:24.721 SERIAL » [ACK] (0x06) 12:19:24.722 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 0 12:19:24.728 SERIAL » 0x010a00131d03700505252d80 (12 bytes) 12:19:24.729 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 45 └─[ConfigurationCCGet] parameter #: 5 12:19:24.730 CNTRLR « [Node 023] parameter #31 has value: 0 12:19:24.730 CNTRLR » [Node 023] querying parameter #32 value... 12:19:24.735 SERIAL « [ACK] (0x06) 12:19:24.741 SERIAL « 0x0104011301e8 (6 bytes) 12:19:24.744 SERIAL » [ACK] (0x06) 12:19:24.746 DRIVER « [RES] [SendData] was sent: true 12:19:24.784 SERIAL « 0x010700132d000005c3 (9 bytes) 12:19:24.784 SERIAL » [ACK] (0x06) 12:19:24.786 DRIVER « [REQ] [SendData] callback id: 45 transmit status: OK 12:19:24.837 SERIAL « 0x010b0004001d0570060501ff65 (13 bytes) 12:19:24.841 CNTRLR [Node 029] [~] [Configuration] 5: 255 => 255 12:19:24.842 SERIAL » [ACK] (0x06) 12:19:24.843 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 1 value: 255 12:19:24.848 SERIAL » 0x010a00131703700520252eac (12 bytes) 12:19:24.848 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 46 └─[ConfigurationCCGet] parameter #: 32 12:19:24.849 CNTRLR « [Node 029] parameter #5 has value: 255 12:19:24.849 CNTRLR » [Node 029] querying parameter #7 value... 12:19:24.854 SERIAL « [ACK] (0x06) 12:19:24.857 SERIAL « 0x0104011301e8 (6 bytes) 12:19:24.858 SERIAL » [ACK] (0x06) 12:19:24.860 DRIVER « [RES] [SendData] was sent: true 12:19:24.925 SERIAL « 0x010700132e000007c2 (9 bytes) 12:19:24.925 SERIAL » [ACK] (0x06) 12:19:24.926 DRIVER « [REQ] [SendData] callback id: 46 transmit status: OK 12:19:24.937 SERIAL « 0x010c0004001706700620020258e8 (14 bytes) 12:19:24.940 CNTRLR [Node 023] [~] [Configuration] 32: 600 => 600 12:19:24.940 SERIAL » [ACK] (0x06) 12:19:24.947 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 2 value: 600 12:19:24.953 SERIAL » 0x010a00131d03700507252f80 (12 bytes) 12:19:24.954 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 47 └─[ConfigurationCCGet] parameter #: 7 12:19:24.954 CNTRLR « [Node 023] parameter #32 has value: 600 12:19:24.954 CNTRLR » [Node 023] querying parameter #40 value... 12:19:24.962 SERIAL « [ACK] (0x06) 12:19:24.964 SERIAL « 0x0104011301e8 (6 bytes) 12:19:24.964 SERIAL » [ACK] (0x06) 12:19:24.967 DRIVER « [RES] [SendData] was sent: true 12:19:25.008 SERIAL « 0x010700132f000005c1 (9 bytes) 12:19:25.009 SERIAL » [ACK] (0x06) 12:19:25.009 DRIVER « [REQ] [SendData] callback id: 47 transmit status: OK 12:19:25.061 SERIAL « 0x010b0004001d0570060701ff67 (13 bytes) 12:19:25.065 CNTRLR [Node 029] [~] [Configuration] 7: 255 => 255 12:19:25.066 SERIAL » [ACK] (0x06) 12:19:25.067 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 7 value size: 1 value: 255 12:19:25.074 SERIAL » 0x010a001317037005282530ba (12 bytes) 12:19:25.075 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 48 └─[ConfigurationCCGet] parameter #: 40 12:19:25.075 CNTRLR « [Node 029] parameter #7 has value: 255 12:19:25.075 CNTRLR » [Node 029] querying parameter #10 value... 12:19:25.079 SERIAL « [ACK] (0x06) 12:19:25.085 SERIAL « 0x0104011301e8 (6 bytes) 12:19:25.086 SERIAL » [ACK] (0x06) 12:19:25.087 DRIVER « [RES] [SendData] was sent: true 12:19:25.145 SERIAL « 0x0107001330000007dc (9 bytes) 12:19:25.145 SERIAL » [ACK] (0x06) 12:19:25.146 DRIVER « [REQ] [SendData] callback id: 48 transmit status: OK 12:19:25.157 SERIAL « 0x010c00040017067006280261a873 (14 bytes) 12:19:25.160 CNTRLR [Node 023] [~] [Configuration] 40: 25000 => 25000 12:19:25.160 SERIAL » [ACK] (0x06) 12:19:25.162 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 2 value: 25000 12:19:25.182 SERIAL » 0x010a00131d0370050a253193 (12 bytes) 12:19:25.183 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 49 └─[ConfigurationCCGet] parameter #: 10 12:19:25.184 CNTRLR « [Node 023] parameter #40 has value: 25000 12:19:25.184 CNTRLR » [Node 023] querying parameter #41 value... 12:19:25.190 SERIAL « [ACK] (0x06) 12:19:25.192 SERIAL « 0x0104011301e8 (6 bytes) 12:19:25.193 SERIAL » [ACK] (0x06) 12:19:25.194 DRIVER « [RES] [SendData] was sent: true 12:19:25.237 SERIAL « 0x0107001331000005df (9 bytes) 12:19:25.238 SERIAL » [ACK] (0x06) 12:19:25.238 DRIVER « [REQ] [SendData] callback id: 49 transmit status: OK 12:19:25.289 SERIAL « 0x010c0004001d0670060a02000092 (14 bytes) 12:19:25.292 CNTRLR [Node 029] [~] [Configuration] 10: 0 => 0 12:19:25.293 SERIAL » [ACK] (0x06) 12:19:25.294 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 2 value: 0 12:19:25.303 SERIAL » 0x010a001317037005292532b9 (12 bytes) 12:19:25.304 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 50 └─[ConfigurationCCGet] parameter #: 41 12:19:25.305 CNTRLR « [Node 029] parameter #10 has value: 0 12:19:25.305 CNTRLR » [Node 029] querying parameter #12 value... 12:19:25.320 SERIAL « [ACK] (0x06) 12:19:25.321 SERIAL « 0x0104011301e8 (6 bytes) 12:19:25.322 SERIAL » [ACK] (0x06) 12:19:25.324 DRIVER « [RES] [SendData] was sent: true 12:19:25.375 SERIAL « 0x0107001332000007de (9 bytes) 12:19:25.376 SERIAL » [ACK] (0x06) 12:19:25.376 DRIVER « [REQ] [SendData] callback id: 50 transmit status: OK 12:19:25.386 SERIAL « 0x010b00040017057006290101bd (13 bytes) 12:19:25.390 CNTRLR [Node 023] [~] [Configuration] 41: 1 => 1 12:19:25.391 SERIAL » [ACK] (0x06) 12:19:25.392 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 41 value size: 1 value: 1 12:19:25.397 SERIAL » 0x010a00131d0370050c253397 (12 bytes) 12:19:25.398 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 51 └─[ConfigurationCCGet] parameter #: 12 12:19:25.399 CNTRLR « [Node 023] parameter #41 has value: 1 12:19:25.399 CNTRLR » [Node 023] querying parameter #42 value... 12:19:25.408 SERIAL « [ACK] (0x06) 12:19:25.410 SERIAL « 0x0104011301e8 (6 bytes) 12:19:25.411 SERIAL » [ACK] (0x06) 12:19:25.413 DRIVER « [RES] [SendData] was sent: true 12:19:25.453 SERIAL « 0x0107001333000005dd (9 bytes) 12:19:25.454 SERIAL » [ACK] (0x06) 12:19:25.455 DRIVER « [REQ] [SendData] callback id: 51 transmit status: OK 12:19:25.505 SERIAL « 0x010b0004001d0570060c011487 (13 bytes) 12:19:25.508 CNTRLR [Node 029] [~] [Configuration] 12: 20 => 20 12:19:25.509 SERIAL » [ACK] (0x06) 12:19:25.510 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 1 value: 20 12:19:25.524 SERIAL » 0x010a0013170370052a2534bc (12 bytes) 12:19:25.525 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 52 └─[ConfigurationCCGet] parameter #: 42 12:19:25.526 CNTRLR « [Node 029] parameter #12 has value: 20 12:19:25.526 CNTRLR » [Node 029] querying parameter #13 value... 12:19:25.530 SERIAL « [ACK] (0x06) 12:19:25.533 SERIAL « 0x0104011301e8 (6 bytes) 12:19:25.534 SERIAL » [ACK] (0x06) 12:19:25.536 DRIVER « [RES] [SendData] was sent: true 12:19:25.595 SERIAL « 0x0107001334000007d8 (9 bytes) 12:19:25.595 SERIAL » [ACK] (0x06) 12:19:25.596 DRIVER « [REQ] [SendData] callback id: 52 transmit status: OK 12:19:25.614 SERIAL « 0x010b000400170570062a0100bf (13 bytes) 12:19:25.617 CNTRLR [Node 023] [~] [Configuration] 42: 0 => 0 12:19:25.618 SERIAL » [ACK] (0x06) 12:19:25.619 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 0 12:19:25.623 SERIAL » 0x010a00131d0370050d253590 (12 bytes) 12:19:25.624 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 53 └─[ConfigurationCCGet] parameter #: 13 12:19:25.625 CNTRLR « [Node 023] parameter #42 has value: 0 12:19:25.625 CNTRLR » [Node 023] querying parameter #43 value... 12:19:25.629 SERIAL « [ACK] (0x06) 12:19:25.634 SERIAL « 0x0104011301e8 (6 bytes) 12:19:25.635 SERIAL » [ACK] (0x06) 12:19:25.636 DRIVER « [RES] [SendData] was sent: true 12:19:25.679 SERIAL « 0x0107001335000005db (9 bytes) 12:19:25.680 SERIAL » [ACK] (0x06) 12:19:25.680 DRIVER « [REQ] [SendData] callback id: 53 transmit status: OK 12:19:25.730 SERIAL « 0x010b0004001d0570060d010092 (13 bytes) 12:19:25.739 CNTRLR [Node 029] [~] [Configuration] 13: 0 => 0 12:19:25.740 SERIAL » [ACK] (0x06) 12:19:25.741 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 0 12:19:25.748 SERIAL » 0x010a0013170370052b2536bf (12 bytes) 12:19:25.748 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 54 └─[ConfigurationCCGet] parameter #: 43 12:19:25.749 CNTRLR « [Node 029] parameter #13 has value: 0 12:19:25.749 CNTRLR » [Node 029] querying parameter #73 value... 12:19:25.755 SERIAL « [ACK] (0x06) 12:19:25.757 SERIAL « 0x0104011301e8 (6 bytes) 12:19:25.758 SERIAL » [ACK] (0x06) 12:19:25.760 DRIVER « [RES] [SendData] was sent: true 12:19:25.815 SERIAL « 0x0107001336000006db (9 bytes) 12:19:25.815 SERIAL » [ACK] (0x06) 12:19:25.816 DRIVER « [REQ] [SendData] callback id: 54 transmit status: OK 12:19:25.827 SERIAL « 0x010b000400170570062b0102bc (13 bytes) 12:19:25.831 CNTRLR [Node 023] [~] [Configuration] 43: 2 => 2 12:19:25.832 SERIAL » [ACK] (0x06) 12:19:25.833 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 2 12:19:25.842 SERIAL » 0x010a00131d037005492537d6 (12 bytes) 12:19:25.842 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 55 └─[ConfigurationCCGet] parameter #: 73 12:19:25.843 CNTRLR « [Node 023] parameter #43 has value: 2 12:19:25.843 CNTRLR » [Node 023] querying parameter #50 value... 12:19:25.848 SERIAL « [ACK] (0x06) 12:19:25.851 SERIAL « 0x0104011301e8 (6 bytes) 12:19:25.853 SERIAL » [ACK] (0x06) 12:19:25.854 DRIVER « [RES] [SendData] was sent: true 12:19:25.897 SERIAL « 0x0107001337000005d9 (9 bytes) 12:19:25.898 SERIAL » [ACK] (0x06) 12:19:25.899 DRIVER « [REQ] [SendData] callback id: 55 transmit status: OK 12:19:25.949 SERIAL « 0x010c0004001d06700649020000d1 (14 bytes) 12:19:25.953 CNTRLR [Node 029] [~] [Configuration] 73: 0 => 0 12:19:25.954 SERIAL » [ACK] (0x06) 12:19:25.955 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 73 value size: 2 value: 0 12:19:25.961 SERIAL » 0x010a001317037005322538a8 (12 bytes) 12:19:25.962 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 56 └─[ConfigurationCCGet] parameter #: 50 12:19:25.962 CNTRLR « [Node 029] parameter #73 has value: 0 12:19:25.963 CNTRLR » [Node 029] querying parameter #80 value... 12:19:25.968 SERIAL « [ACK] (0x06) 12:19:25.971 SERIAL « 0x0104011301e8 (6 bytes) 12:19:25.972 SERIAL » [ACK] (0x06) 12:19:25.974 DRIVER « [RES] [SendData] was sent: true 12:19:26.045 SERIAL « 0x0107001338000008db (9 bytes) 12:19:26.045 SERIAL » [ACK] (0x06) 12:19:26.046 DRIVER « [REQ] [SendData] callback id: 56 transmit status: OK 12:19:26.056 SERIAL « 0x010b00040017057006320103a4 (13 bytes) 12:19:26.061 CNTRLR [Node 023] [~] [Configuration] 50: 3 => 3 12:19:26.062 SERIAL » [ACK] (0x06) 12:19:26.063 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 3 12:19:26.070 SERIAL » 0x010a00131d037005502539c1 (12 bytes) 12:19:26.070 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 57 └─[ConfigurationCCGet] parameter #: 80 12:19:26.071 CNTRLR « [Node 023] parameter #50 has value: 3 12:19:26.072 CNTRLR [Node 023] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 12:19:26.091 SERIAL « [ACK] (0x06) 12:19:26.095 SERIAL « 0x0104011301e8 (6 bytes) 12:19:26.096 SERIAL » [ACK] (0x06) 12:19:26.098 DRIVER « [RES] [SendData] was sent: true 12:19:26.102 CNTRLR [Node 023] AssociationCC: doing a partial interview... 12:19:26.102 CNTRLR [Node 023] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 12:19:26.103 CNTRLR [Node 023] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 12:19:26.107 CNTRLR [Node 023] MultiChannelAssociationCC: doing a partial interview... 12:19:26.107 CNTRLR » [Node 023] querying multi channel association group #1... 12:19:26.150 SERIAL « 0x0107001339000005d7 (9 bytes) 12:19:26.151 SERIAL » [ACK] (0x06) 12:19:26.152 DRIVER « [REQ] [SendData] callback id: 57 transmit status: OK 12:19:26.177 SERIAL « 0x010b0004001d057006500101ce (13 bytes) 12:19:26.181 CNTRLR [Node 029] [~] [Configuration] 80: 1 => 1 12:19:26.182 SERIAL » [ACK] (0x06) 12:19:26.184 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 80 value size: 1 value: 1 12:19:26.194 SERIAL » 0x010800131e0100253ae4 (10 bytes) 12:19:26.194 DRIVER » [Node 030] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 58 └─[NoOperationCC] 12:19:26.195 CNTRLR « [Node 029] parameter #80 has value: 1 12:19:26.195 CNTRLR » [Node 029] querying parameter #81 value... 12:19:26.200 SERIAL « [ACK] (0x06) 12:19:26.203 SERIAL « 0x0104011301e8 (6 bytes) 12:19:26.203 SERIAL » [ACK] (0x06) 12:19:26.204 DRIVER « [RES] [SendData] was sent: true 12:19:33.083 SERIAL « 0x010700133a0102b163 (9 bytes) 12:19:33.083 SERIAL » [ACK] (0x06) 12:19:33.084 DRIVER « [REQ] [SendData] callback id: 58 transmit status: NoAck 12:19:33.089 SERIAL » 0x010a00131d03700551253bc2 (12 bytes) 12:19:33.090 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 59 └─[ConfigurationCCGet] parameter #: 81 12:19:33.090 CNTRLR [Node 030] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 12:19:33.091 CNTRLR [Node 030] The node is asleep. 12:19:33.092 CNTRLR [Node 030] The node is ready to be used 12:19:33.093 CNTRLR [Node 030] ping failed: Failed to send the command after 1 attempts (Status No Ack) 12:19:33.096 CNTRLR [Node 030] ManufacturerSpecificCC: doing a partial interview... 12:19:33.097 CNTRLR [Node 030] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 12:19:33.109 SERIAL « [ACK] (0x06) 12:19:33.111 SERIAL « 0x0104011301e8 (6 bytes) 12:19:33.112 SERIAL » [ACK] (0x06) 12:19:33.113 DRIVER « [RES] [SendData] was sent: true 12:19:33.117 CNTRLR [Node 030] VersionCC: doing a partial interview... 12:19:33.118 CNTRLR [Node 030] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:19:33.118 CNTRLR [Node 030] trying to load device config 12:19:33.128 CNTRLR [Node 030] device config loaded 12:19:33.129 CNTRLR [Node 030] ZWavePlusCC: doing a partial interview... 12:19:33.130 CNTRLR [Node 030] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 12:19:33.130 CNTRLR [Node 030] BatteryCC: doing a partial interview... 12:19:33.130 CNTRLR » [Node 030] querying battery status... 12:19:33.336 SERIAL « 0x010700133b000005d5 (9 bytes) 12:19:33.337 SERIAL » [ACK] (0x06) 12:19:33.340 DRIVER « [REQ] [SendData] callback id: 59 transmit status: OK 12:19:33.347 SERIAL « 0x010b0004001d057006510136f8 (13 bytes) 12:19:33.351 CNTRLR [Node 029] [~] [Configuration] 81: 54 => 54 12:19:33.353 SERIAL » [ACK] (0x06) 12:19:33.355 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 81 value size: 1 value: 54 12:19:33.359 SERIAL » 0x010800131f0100253ce3 (10 bytes) 12:19:33.360 DRIVER » [Node 031] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 60 └─[NoOperationCC] 12:19:33.360 CNTRLR « [Node 029] parameter #81 has value: 54 12:19:33.361 CNTRLR » [Node 029] querying parameter #82 value... 12:19:33.374 SERIAL « [ACK] (0x06) 12:19:33.376 SERIAL « 0x0104011301e8 (6 bytes) 12:19:33.377 SERIAL » [ACK] (0x06) 12:19:33.378 DRIVER « [RES] [SendData] was sent: true 12:19:40.077 SERIAL « 0x010700133c01029f4b (9 bytes) 12:19:40.078 SERIAL » [ACK] (0x06) 12:19:40.079 DRIVER « [REQ] [SendData] callback id: 60 transmit status: NoAck 12:19:40.087 SERIAL » 0x010a00131d03700552253dc7 (12 bytes) 12:19:40.088 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 61 └─[ConfigurationCCGet] parameter #: 82 12:19:40.089 CNTRLR [Node 031] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 12:19:40.090 CNTRLR [Node 031] The node is asleep. 12:19:40.091 CNTRLR [Node 031] The node is ready to be used 12:19:40.093 CNTRLR [Node 031] ping failed: Failed to send the command after 1 attempts (Status No Ack) 12:19:40.096 CNTRLR [Node 031] ManufacturerSpecificCC: doing a partial interview... 12:19:40.096 CNTRLR [Node 031] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 12:19:40.109 SERIAL « [ACK] (0x06) 12:19:40.121 SERIAL « 0x0104011301e8 (6 bytes) 12:19:40.121 SERIAL » [ACK] (0x06) 12:19:40.122 DRIVER « [RES] [SendData] was sent: true 12:19:40.128 CNTRLR [Node 031] VersionCC: doing a partial interview... 12:19:40.128 CNTRLR [Node 031] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:19:40.130 CNTRLR [Node 031] trying to load device config 12:19:40.141 CNTRLR [Node 031] device config loaded 12:19:40.142 CNTRLR [Node 031] ZWavePlusCC: doing a partial interview... 12:19:40.142 CNTRLR [Node 031] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 12:19:40.143 CNTRLR [Node 031] BatteryCC: doing a partial interview... 12:19:40.143 CNTRLR » [Node 031] querying battery status... 12:19:40.147 SERIAL « 0x010700133d000005d3 (9 bytes) 12:19:40.148 SERIAL » [ACK] (0x06) 12:19:40.149 DRIVER « [REQ] [SendData] callback id: 61 transmit status: OK 12:19:40.313 SERIAL « 0x010b0004001d057006520102cf (13 bytes) 12:19:40.316 CNTRLR [Node 029] [~] [Configuration] 82: 2 => 2 12:19:40.316 SERIAL » [ACK] (0x06) 12:19:40.318 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 82 value size: 1 value: 2 12:19:40.329 SERIAL » 0x01080013200100253ede (10 bytes) 12:19:40.329 DRIVER » [Node 032] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 62 └─[NoOperationCC] 12:19:40.330 CNTRLR « [Node 029] parameter #82 has value: 2 12:19:40.330 CNTRLR » [Node 029] querying parameter #83 value... 12:19:40.335 SERIAL « [ACK] (0x06) 12:19:40.339 SERIAL « 0x0104011301e8 (6 bytes) 12:19:40.339 SERIAL » [ACK] (0x06) 12:19:40.341 DRIVER « [RES] [SendData] was sent: true 12:19:47.127 SERIAL « 0x010700133e0102a771 (9 bytes) 12:19:47.127 SERIAL » [ACK] (0x06) 12:19:47.128 DRIVER « [REQ] [SendData] callback id: 62 transmit status: NoAck 12:19:47.137 SERIAL » 0x010a00131d03700553253fc4 (12 bytes) 12:19:47.137 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 63 └─[ConfigurationCCGet] parameter #: 83 12:19:47.138 CNTRLR [Node 032] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 12:19:47.138 CNTRLR [Node 032] The node is asleep. 12:19:47.140 CNTRLR [Node 032] The node is ready to be used 12:19:47.141 CNTRLR [Node 032] ping failed: Failed to send the command after 1 attempts (Status No Ack) 12:19:47.143 CNTRLR [Node 032] ManufacturerSpecificCC: doing a partial interview... 12:19:47.143 CNTRLR [Node 032] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 12:19:47.153 SERIAL « [ACK] (0x06) 12:19:47.156 SERIAL « 0x0104011301e8 (6 bytes) 12:19:47.157 SERIAL » [ACK] (0x06) 12:19:47.159 DRIVER « [RES] [SendData] was sent: true 12:19:47.163 CNTRLR [Node 032] VersionCC: doing a partial interview... 12:19:47.163 CNTRLR [Node 032] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:19:47.164 CNTRLR [Node 032] trying to load device config 12:19:47.173 CNTRLR [Node 032] device config loaded 12:19:47.173 CNTRLR [Node 032] ZWavePlusCC: doing a partial interview... 12:19:47.174 CNTRLR [Node 032] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 12:19:47.174 CNTRLR [Node 032] BatteryCC: doing a partial interview... 12:19:47.175 CNTRLR » [Node 032] querying battery status... 12:19:47.387 SERIAL « 0x010700133f000005d1 (9 bytes) 12:19:47.388 SERIAL » [ACK] (0x06) 12:19:47.398 DRIVER « [REQ] [SendData] callback id: 63 transmit status: OK 12:19:47.408 SERIAL « 0x010b0004001d057006530102ce (13 bytes) 12:19:47.411 CNTRLR [Node 029] [~] [Configuration] 83: 2 => 2 12:19:47.412 SERIAL » [ACK] (0x06) 12:19:47.413 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 83 value size: 1 value: 2 12:19:47.418 SERIAL » 0x010800132101002540a1 (10 bytes) 12:19:47.418 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 64 └─[NoOperationCC] 12:19:47.419 CNTRLR « [Node 029] parameter #83 has value: 2 12:19:47.419 CNTRLR » [Node 029] querying parameter #84 value... 12:19:47.425 SERIAL « [ACK] (0x06) 12:19:47.431 SERIAL « 0x0104011301e8 (6 bytes) 12:19:47.432 SERIAL » [ACK] (0x06) 12:19:47.434 DRIVER « [RES] [SendData] was sent: true 12:19:54.149 SERIAL « 0x01070013400102a008 (9 bytes) 12:19:54.149 SERIAL » [ACK] (0x06) 12:19:54.150 DRIVER « [REQ] [SendData] callback id: 64 transmit status: NoAck 12:19:54.155 SERIAL » 0x010a00131d037005542541bd (12 bytes) 12:19:54.156 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 65 └─[ConfigurationCCGet] parameter #: 84 12:19:54.156 CNTRLR [Node 033] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 12:19:54.157 CNTRLR [Node 033] The node is asleep. 12:19:54.158 CNTRLR [Node 033] The node is ready to be used 12:19:54.159 CNTRLR [Node 033] ping failed: Failed to send the command after 1 attempts (Status No Ack) 12:19:54.181 CNTRLR [Node 033] ManufacturerSpecificCC: doing a partial interview... 12:19:54.182 CNTRLR [Node 033] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 12:19:54.199 SERIAL « [ACK] (0x06) 12:19:54.201 SERIAL « 0x0104011301e8 (6 bytes) 12:19:54.202 SERIAL » [ACK] (0x06) 12:19:54.213 DRIVER « [RES] [SendData] was sent: true 12:19:54.222 CNTRLR [Node 033] VersionCC: doing a partial interview... 12:19:54.222 CNTRLR [Node 033] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:19:54.223 CNTRLR [Node 033] trying to load device config 12:19:54.225 SERIAL « 0x0107001341000005af (9 bytes) 12:19:54.226 SERIAL » [ACK] (0x06) 12:19:54.229 DRIVER « [REQ] [SendData] callback id: 65 transmit status: OK 12:19:54.242 CNTRLR [Node 033] device config loaded 12:19:54.243 CNTRLR [Node 033] ZWavePlusCC: doing a partial interview... 12:19:54.243 CNTRLR [Node 033] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 12:19:54.244 CNTRLR [Node 033] BatteryCC: doing a partial interview... 12:19:54.244 CNTRLR » [Node 033] querying battery status... 12:19:54.415 SERIAL « 0x010b0004001d057006540132f9 (13 bytes) 12:19:54.419 CNTRLR [Node 029] [~] [Configuration] 84: 50 => 50 12:19:54.420 SERIAL » [ACK] (0x06) 12:19:54.438 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 84 value size: 1 value: 50 12:19:54.446 SERIAL » 0x010800132201002542a0 (10 bytes) 12:19:54.447 DRIVER » [Node 034] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 66 └─[NoOperationCC] 12:19:54.448 CNTRLR « [Node 029] parameter #84 has value: 50 12:19:54.449 CNTRLR » [Node 029] querying parameter #85 value... 12:19:54.458 SERIAL « [ACK] (0x06) 12:19:54.461 SERIAL « 0x0104011301e8 (6 bytes) 12:19:54.462 SERIAL » [ACK] (0x06) 12:19:54.463 DRIVER « [RES] [SendData] was sent: true 12:19:58.557 SERIAL « 0x010700134201019a33 (9 bytes) 12:19:58.558 SERIAL » [ACK] (0x06) 12:19:58.559 DRIVER « [REQ] [SendData] callback id: 66 transmit status: NoAck 12:19:58.566 SERIAL » 0x010a00131d037005552543be (12 bytes) 12:19:58.567 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 67 └─[ConfigurationCCGet] parameter #: 85 12:19:58.568 CNTRLR [Node 034] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 12:19:58.569 CNTRLR [Node 034] The node is asleep. 12:19:58.570 CNTRLR [Node 034] The node is ready to be used 12:19:58.572 CNTRLR [Node 034] ping failed: Failed to send the command after 1 attempts (Status No Ack) 12:19:58.576 CNTRLR [Node 034] ManufacturerSpecificCC: doing a partial interview... 12:19:58.576 CNTRLR [Node 034] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 12:19:58.587 SERIAL « [ACK] (0x06) 12:19:58.590 SERIAL « 0x0104011301e8 (6 bytes) 12:19:58.591 SERIAL » [ACK] (0x06) 12:19:58.592 DRIVER « [RES] [SendData] was sent: true 12:19:58.612 CNTRLR [Node 034] VersionCC: doing a partial interview... 12:19:58.613 CNTRLR [Node 034] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:19:58.613 CNTRLR [Node 034] trying to load device config 12:19:58.625 CNTRLR [Node 034] device config loaded 12:19:58.626 CNTRLR [Node 034] ZWavePlusCC: doing a partial interview... 12:19:58.626 CNTRLR [Node 034] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 12:19:58.627 CNTRLR [Node 034] BatteryCC: doing a partial interview... 12:19:58.628 CNTRLR » [Node 034] querying battery status... 12:19:58.632 SERIAL « 0x0107001343000005ad (9 bytes) 12:19:58.633 SERIAL » [ACK] (0x06) 12:19:58.635 DRIVER « [REQ] [SendData] callback id: 67 transmit status: OK 12:19:58.812 SERIAL « 0x010b0004001d057006550105cf (13 bytes) 12:19:58.815 CNTRLR [Node 029] [~] [Configuration] 85: 5 => 5 12:19:58.816 SERIAL » [ACK] (0x06) 12:19:58.825 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 85 value size: 1 value: 5 12:19:58.833 SERIAL » 0x010800132301002544a7 (10 bytes) 12:19:58.833 DRIVER » [Node 035] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 68 └─[NoOperationCC] 12:19:58.834 CNTRLR « [Node 029] parameter #85 has value: 5 12:19:58.834 CNTRLR » [Node 029] querying parameter #86 value... 12:19:58.840 SERIAL « [ACK] (0x06) 12:19:58.844 SERIAL « 0x0104011301e8 (6 bytes) 12:19:58.845 SERIAL » [ACK] (0x06) 12:19:58.846 DRIVER « [RES] [SendData] was sent: true 12:20:05.491 SERIAL « 0x010700134401029a36 (9 bytes) 12:20:05.492 SERIAL » [ACK] (0x06) 12:20:05.494 DRIVER « [REQ] [SendData] callback id: 68 transmit status: NoAck 12:20:05.505 SERIAL » 0x010a00131d037005562545bb (12 bytes) 12:20:05.506 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 69 └─[ConfigurationCCGet] parameter #: 86 12:20:05.516 CNTRLR [Node 035] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 12:20:05.517 CNTRLR [Node 035] The node is asleep. 12:20:05.519 CNTRLR [Node 035] The node is ready to be used 12:20:05.522 CNTRLR [Node 035] ping failed: Failed to send the command after 1 attempts (Status No Ack) 12:20:05.526 CNTRLR [Node 035] ManufacturerSpecificCC: doing a partial interview... 12:20:05.527 CNTRLR [Node 035] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 12:20:05.544 SERIAL « [ACK] (0x06) 12:20:05.545 SERIAL « 0x0104011301e8 (6 bytes) 12:20:05.545 SERIAL » [ACK] (0x06) 12:20:05.552 DRIVER « [RES] [SendData] was sent: true 12:20:05.556 CNTRLR [Node 035] VersionCC: doing a partial interview... 12:20:05.558 CNTRLR [Node 035] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:20:05.558 CNTRLR [Node 035] trying to load device config 12:20:05.569 CNTRLR [Node 035] device config loaded 12:20:05.570 CNTRLR [Node 035] ZWavePlusCC: doing a partial interview... 12:20:05.570 CNTRLR [Node 035] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 12:20:05.571 CNTRLR [Node 035] BatteryCC: doing a partial interview... 12:20:05.571 CNTRLR » [Node 035] querying battery status... 12:20:05.745 SERIAL « 0x0107001345000005ab (9 bytes) 12:20:05.746 SERIAL » [ACK] (0x06) 12:20:05.748 DRIVER « [REQ] [SendData] callback id: 69 transmit status: OK 12:20:05.766 SERIAL « 0x010c0004001d06700656020168a7 (14 bytes) 12:20:05.769 CNTRLR [Node 029] [~] [Configuration] 86: 360 => 360 12:20:05.770 SERIAL » [ACK] (0x06) 12:20:05.772 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 86 value size: 2 value: 360 12:20:05.776 SERIAL » 0x010800132401002546a2 (10 bytes) 12:20:05.776 DRIVER » [Node 036] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 70 └─[NoOperationCC] 12:20:05.777 CNTRLR « [Node 029] parameter #86 has value: 360 12:20:05.777 CNTRLR » [Node 029] querying parameter #87 value... 12:20:05.780 SERIAL « [ACK] (0x06) 12:20:05.784 SERIAL « 0x0104011301e8 (6 bytes) 12:20:05.785 SERIAL » [ACK] (0x06) 12:20:05.786 DRIVER « [RES] [SendData] was sent: true 12:20:12.653 SERIAL « 0x01070013460102b01e (9 bytes) 12:20:12.654 SERIAL » [ACK] (0x06) 12:20:12.655 DRIVER « [REQ] [SendData] callback id: 70 transmit status: NoAck 12:20:12.661 SERIAL » 0x010a00131d037005572547b8 (12 bytes) 12:20:12.662 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 71 └─[ConfigurationCCGet] parameter #: 87 12:20:12.662 CNTRLR [Node 036] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 12:20:12.663 CNTRLR [Node 036] The node is asleep. 12:20:12.664 CNTRLR [Node 036] The node is ready to be used 12:20:12.666 CNTRLR [Node 036] ping failed: Failed to send the command after 1 attempts (Status No Ack) 12:20:12.668 CNTRLR [Node 036] ManufacturerSpecificCC: doing a partial interview... 12:20:12.668 CNTRLR [Node 036] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 12:20:12.679 SERIAL « [ACK] (0x06) 12:20:12.682 SERIAL « 0x0104011301e8 (6 bytes) 12:20:12.682 SERIAL » [ACK] (0x06) 12:20:12.685 DRIVER « [RES] [SendData] was sent: true 12:20:12.689 CNTRLR [Node 036] VersionCC: doing a partial interview... 12:20:12.689 CNTRLR [Node 036] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:20:12.690 CNTRLR [Node 036] trying to load device config 12:20:12.703 CNTRLR [Node 036] device config loaded 12:20:12.704 CNTRLR [Node 036] ZWavePlusCC: doing a partial interview... 12:20:12.704 CNTRLR [Node 036] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 12:20:12.705 CNTRLR [Node 036] BatteryCC: doing a partial interview... 12:20:12.705 CNTRLR » [Node 036] querying battery status... 12:20:12.908 SERIAL « 0x0107001347000005a9 (9 bytes) 12:20:12.909 SERIAL » [ACK] (0x06) 12:20:12.911 DRIVER « [REQ] [SendData] callback id: 71 transmit status: OK 12:20:12.916 SERIAL « 0x010c0004001d06700657020168a6 (14 bytes) 12:20:12.919 CNTRLR [Node 029] [~] [Configuration] 87: 360 => 360 12:20:12.920 SERIAL » [ACK] (0x06) 12:20:12.921 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 87 value size: 2 value: 360 12:20:12.925 SERIAL » 0x010800132501002548ad (10 bytes) 12:20:12.926 DRIVER » [Node 037] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 72 └─[NoOperationCC] 12:20:12.927 CNTRLR « [Node 029] parameter #87 has value: 360 12:20:12.927 CNTRLR » [Node 029] querying parameter #88 value... 12:20:12.932 SERIAL « [ACK] (0x06) 12:20:12.938 SERIAL « 0x0104011301e8 (6 bytes) 12:20:12.938 SERIAL » [ACK] (0x06) 12:20:12.939 DRIVER « [RES] [SendData] was sent: true 12:20:19.621 SERIAL « 0x010700134801029e3e (9 bytes) 12:20:19.622 SERIAL » [ACK] (0x06) 12:20:19.623 DRIVER « [REQ] [SendData] callback id: 72 transmit status: NoAck 12:20:19.634 SERIAL » 0x010a00131d037005582549b9 (12 bytes) 12:20:19.635 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 73 └─[ConfigurationCCGet] parameter #: 88 12:20:19.636 CNTRLR [Node 037] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 12:20:19.637 CNTRLR [Node 037] The node is asleep. 12:20:19.639 CNTRLR [Node 037] The node is ready to be used 12:20:19.641 CNTRLR [Node 037] ping failed: Failed to send the command after 1 attempts (Status No Ack) 12:20:19.645 CNTRLR [Node 037] ManufacturerSpecificCC: doing a partial interview... 12:20:19.646 CNTRLR [Node 037] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 12:20:19.669 SERIAL « [ACK] (0x06) 12:20:19.671 SERIAL « 0x0104011301e8 (6 bytes) 12:20:19.672 SERIAL » [ACK] (0x06) 12:20:19.676 DRIVER « [RES] [SendData] was sent: true 12:20:19.686 CNTRLR [Node 037] VersionCC: doing a partial interview... 12:20:19.688 CNTRLR [Node 037] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:20:19.690 CNTRLR [Node 037] trying to load device config 12:20:19.699 SERIAL « 0x0107001349000005a7 (9 bytes) 12:20:19.700 SERIAL » [ACK] (0x06) 12:20:19.703 DRIVER « [REQ] [SendData] callback id: 73 transmit status: OK 12:20:19.727 CNTRLR [Node 037] device config loaded 12:20:19.728 CNTRLR [Node 037] ZWavePlusCC: doing a partial interview... 12:20:19.729 CNTRLR [Node 037] [~] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue => true 12:20:19.730 CNTRLR [Node 037] BatteryCC: doing a partial interview... 12:20:19.730 CNTRLR » [Node 037] querying battery status... 12:20:19.924 SERIAL « 0x010b0004001d057006580100c7 (13 bytes) 12:20:19.927 CNTRLR [Node 029] [~] [Configuration] 88: 0 => 0 12:20:19.928 SERIAL » [ACK] (0x06) 12:20:19.939 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 88 value size: 1 value: 0 12:20:19.943 SERIAL » 0x01080013260100254aac (10 bytes) 12:20:19.944 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 74 └─[NoOperationCC] 12:20:19.944 CNTRLR « [Node 029] parameter #88 has value: 0 12:20:19.945 CNTRLR » [Node 029] querying parameter #89 value... 12:20:19.955 SERIAL « [ACK] (0x06) 12:20:19.957 SERIAL « 0x0104011301e8 (6 bytes) 12:20:19.957 SERIAL » [ACK] (0x06) 12:20:19.958 DRIVER « [RES] [SendData] was sent: true 12:20:26.535 SERIAL « 0x010700134a01029331 (9 bytes) 12:20:26.536 SERIAL » [ACK] (0x06) 12:20:26.538 DRIVER « [REQ] [SendData] callback id: 74 transmit status: NoAck 12:20:26.551 SERIAL » 0x0109001301028408254b04 (11 bytes) 12:20:26.552 DRIVER » [Node 001] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 75 └─[WakeUpCCNoMoreInformation] 12:20:26.553 CNTRLR [Node 038] The node did not respond after 1 attempts. It is probably asleep, moving its messages to the wakeup queue. 12:20:26.554 CNTRLR [Node 038] The node is asleep. 12:20:26.556 CNTRLR [Node 038] The node is ready to be used 12:20:26.557 CNTRLR All nodes are ready to be used 12:20:26.560 CNTRLR [Node 038] ping failed: Failed to send the command after 1 attempts (Status No Ack) 12:20:26.564 CNTRLR [Node 038] ManufacturerSpecificCC: doing a partial interview... 12:20:26.565 CNTRLR [Node 038] [~] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true => true 12:20:26.587 SERIAL « [ACK] (0x06) 12:20:26.598 CNTRLR [Node 038] VersionCC: doing a partial interview... 12:20:26.599 CNTRLR [Node 038] [~] [Version] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:20:26.600 CNTRLR [Node 038] trying to load device config 12:20:26.629 CNTRLR [Node 038] device config loaded 12:20:26.631 CNTRLR [Node 038] BatteryCC: doing a partial interview... 12:20:26.631 CNTRLR » [Node 038] querying battery status... 12:20:26.747 SERIAL « 0x0104011301e8 (6 bytes) 12:20:26.747 SERIAL » [ACK] (0x06) 12:20:26.750 DRIVER « [RES] [SendData] was sent: true 12:20:26.817 SERIAL « 0x010700134b000019b9 (9 bytes) 12:20:26.817 SERIAL » [ACK] (0x06) 12:20:26.818 DRIVER « [REQ] [SendData] callback id: 75 transmit status: OK 12:20:26.829 SERIAL » 0x010a001317038e0201254c16 (12 bytes) 12:20:26.829 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 76 └─[MultiChannelAssociationCCGet] group id: 1 12:20:26.831 CNTRLR [Node 001] The node is asleep. 12:20:26.834 SERIAL « [ACK] (0x06) 12:20:26.839 SERIAL « 0x0104011301e8 (6 bytes) 12:20:26.841 SERIAL » [ACK] (0x06) 12:20:26.842 DRIVER « [RES] [SendData] was sent: true 12:20:26.885 SERIAL « 0x010700134c000005a2 (9 bytes) 12:20:26.886 SERIAL » [ACK] (0x06) 12:20:26.887 DRIVER « [REQ] [SendData] callback id: 76 transmit status: OK 12:20:26.897 SERIAL « 0x010e00040017088e0301010000010066 (16 bytes) 12:20:26.899 SERIAL » [ACK] (0x06) 12:20:26.901 CNTRLR [Node 023] [~] [Multi Channel Association] maxNodes[1]: 1 => 1 12:20:26.902 CNTRLR [Node 023] [~] [Multi Channel Association] nodeIds[1]: => 12:20:26.903 CNTRLR [Node 023] [~] [Multi Channel Association] endpoints[1]: [object Object] => [o bject Object] 12:20:26.904 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 1 node ids: endpoints: 1:0 12:20:26.909 SERIAL » 0x010a00131d03700559254dbc (12 bytes) 12:20:26.909 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 77 └─[ConfigurationCCGet] parameter #: 89 12:20:26.910 CNTRLR « [Node 023] received information for multi channel association group #1: maximum # of nodes: 1 currently assigned nodes: currently assigned endpoints: 1:0 12:20:26.910 CNTRLR » [Node 023] querying multi channel association group #2... 12:20:26.915 SERIAL « [ACK] (0x06) 12:20:26.922 SERIAL « 0x0104011301e8 (6 bytes) 12:20:26.923 SERIAL » [ACK] (0x06) 12:20:26.925 DRIVER « [RES] [SendData] was sent: true 12:20:26.964 SERIAL « 0x010700134d000005a3 (9 bytes) 12:20:26.964 SERIAL » [ACK] (0x06) 12:20:26.965 DRIVER « [REQ] [SendData] callback id: 77 transmit status: OK 12:20:27.017 SERIAL « 0x010b0004001d057006590101c7 (13 bytes) 12:20:27.021 CNTRLR [Node 029] [~] [Configuration] 89: 1 => 1 12:20:27.024 SERIAL » [ACK] (0x06) 12:20:27.026 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 89 value size: 1 value: 1 12:20:27.060 SERIAL » 0x010a001317038e0202254e17 (12 bytes) 12:20:27.060 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 78 └─[MultiChannelAssociationCCGet] group id: 2 12:20:27.061 CNTRLR « [Node 029] parameter #89 has value: 1 12:20:27.062 CNTRLR [Node 029] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 12:20:27.072 SERIAL « [ACK] (0x06) 12:20:27.075 SERIAL « 0x0104011301e8 (6 bytes) 12:20:27.076 SERIAL » [ACK] (0x06) 12:20:27.078 DRIVER « [RES] [SendData] was sent: true 12:20:27.083 CNTRLR [Node 029] AlarmSensorCC: doing a partial interview... 12:20:27.084 CNTRLR » [Node 029] querying current value for General Purpose... 12:20:27.105 SERIAL « 0x010700134e000004a1 (9 bytes) 12:20:27.106 SERIAL » [ACK] (0x06) 12:20:27.106 DRIVER « [REQ] [SendData] callback id: 78 transmit status: OK 12:20:27.117 SERIAL « 0x010b00040017058e03020a0067 (13 bytes) 12:20:27.117 SERIAL » [ACK] (0x06) 12:20:27.119 CNTRLR [Node 023] [~] [Multi Channel Association] maxNodes[2]: 10 => 10 12:20:27.120 CNTRLR [Node 023] [~] [Multi Channel Association] nodeIds[2]: => 12:20:27.122 CNTRLR [Node 023] [~] [Multi Channel Association] endpoints[2]: => 12:20:27.123 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 10 node ids: endpoints: 12:20:27.129 SERIAL » 0x010a00131d039c0100254f0f (12 bytes) 12:20:27.130 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 79 └─[AlarmSensorCCGet] sensor type: General Purpose 12:20:27.131 CNTRLR « [Node 023] received information for multi channel association group #2: maximum # of nodes: 10 currently assigned nodes: currently assigned endpoints: 12:20:27.132 CNTRLR » [Node 023] querying multi channel association group #3... 12:20:27.137 SERIAL « [ACK] (0x06) 12:20:27.141 SERIAL « 0x0104011301e8 (6 bytes) 12:20:27.142 SERIAL » [ACK] (0x06) 12:20:27.143 DRIVER « [RES] [SendData] was sent: true 12:20:27.185 SERIAL « 0x010700134f000005a1 (9 bytes) 12:20:27.185 SERIAL » [ACK] (0x06) 12:20:27.186 DRIVER « [REQ] [SendData] callback id: 79 transmit status: OK 12:20:27.239 SERIAL « 0x010d0004001d079c021d000000006f (15 bytes) 12:20:27.242 CNTRLR [Node 029] [~] [Alarm Sensor] state[0]: false => false [Endpoint 0] 12:20:27.243 CNTRLR [Node 029] [+] [Alarm Sensor] severity[0]: undefined [Endpoint 0] 12:20:27.244 CNTRLR [Node 029] [+] [Alarm Sensor] duration[0]: undefined [Endpoint 0] 12:20:27.245 SERIAL » [ACK] (0x06) 12:20:27.247 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: false 12:20:27.251 SERIAL » 0x010a001317038e0203255008 (12 bytes) 12:20:27.252 DRIVER » [Node 023] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 80 └─[MultiChannelAssociationCCGet] group id: 3 12:20:27.252 CNTRLR « [Node 029] received current value for General Purpose: state: false 12:20:27.253 CNTRLR » [Node 029] querying current value for Smoke... 12:20:27.257 SERIAL « [ACK] (0x06) 12:20:27.262 SERIAL « 0x0104011301e8 (6 bytes) 12:20:27.263 SERIAL » [ACK] (0x06) 12:20:27.265 DRIVER « [RES] [SendData] was sent: true 12:20:27.329 SERIAL « 0x0107001350000007bc (9 bytes) 12:20:27.330 SERIAL » [ACK] (0x06) 12:20:27.331 DRIVER « [REQ] [SendData] callback id: 80 transmit status: OK 12:20:27.341 SERIAL « 0x010b00040017058e03030a0066 (13 bytes) 12:20:27.341 SERIAL » [ACK] (0x06) 12:20:27.343 CNTRLR [Node 023] [~] [Multi Channel Association] maxNodes[3]: 10 => 10 12:20:27.344 CNTRLR [Node 023] [~] [Multi Channel Association] nodeIds[3]: => 12:20:27.345 CNTRLR [Node 023] [~] [Multi Channel Association] endpoints[3]: => 12:20:27.346 DRIVER « [Node 023] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 3 maximum # of nodes: 10 node ids: endpoints: 12:20:27.350 SERIAL » 0x010a00131d039c0101255110 (12 bytes) 12:20:27.350 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 81 └─[AlarmSensorCCGet] sensor type: Smoke 12:20:27.351 CNTRLR « [Node 023] received information for multi channel association group #3: maximum # of nodes: 10 currently assigned nodes: currently assigned endpoints: 12:20:27.352 CNTRLR [Node 023] [~] [Association] hasLifeline: true => true [internal] 12:20:27.352 CNTRLR [Node 023] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 12:20:27.361 SERIAL « [ACK] (0x06) 12:20:27.364 SERIAL « 0x0104011301e8 (6 bytes) 12:20:27.365 SERIAL » [ACK] (0x06) 12:20:27.368 DRIVER « [RES] [SendData] was sent: true 12:20:27.375 CNTRLR [Node 023] AssociationGroupInfoCC: doing a partial interview... 12:20:27.376 CNTRLR [Node 023] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 12:20:27.377 CNTRLR [Node 023] NotificationCC: doing a partial interview... 12:20:27.377 CNTRLR [Node 023] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 12:20:27.378 CNTRLR [Node 023] Interview stage completed: CommandClasses 12:20:27.381 CNTRLR [Node 023] Interview stage completed: OverwriteConfig 12:20:27.381 CNTRLR » [Node 023] requesting node neighbors... 12:20:27.406 SERIAL « 0x0107001351000005bf (9 bytes) 12:20:27.406 SERIAL » [ACK] (0x06) 12:20:27.407 DRIVER « [REQ] [SendData] callback id: 81 transmit status: OK 12:20:27.458 SERIAL « 0x010d0004001d079c021d010000006e (15 bytes) 12:20:27.459 CNTRLR [Node 029] [~] [Alarm Sensor] state[1]: false => false [Endpoint 0] 12:20:27.459 CNTRLR [Node 029] [+] [Alarm Sensor] severity[1]: undefined [Endpoint 0] 12:20:27.460 CNTRLR [Node 029] [+] [Alarm Sensor] duration[1]: undefined [Endpoint 0] 12:20:27.460 SERIAL » [ACK] (0x06) 12:20:27.462 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: Smoke alarm state: false 12:20:27.466 SERIAL » 0x01070080170000006f (9 bytes) 12:20:27.470 DRIVER » [Node 023] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 12:20:27.471 CNTRLR « [Node 029] received current value for Smoke: state: false 12:20:27.471 CNTRLR » [Node 029] querying current value for Heat... 12:20:27.476 SERIAL « [ACK] (0x06) 12:20:27.479 SERIAL « 0x01200180810080f53d00000000000000000000000000000000000000000000000 (34 bytes) 097 12:20:27.479 SERIAL » [ACK] (0x06) 12:20:27.481 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 8, 24, 25, 27, 29, 30, 31, 32, 33, 35, 36, 37, 38 12:20:27.488 SERIAL » 0x010a00131d039c0104255216 (12 bytes) 12:20:27.488 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 82 └─[AlarmSensorCCGet] sensor type: Heat 12:20:27.489 CNTRLR « [Node 023] node neighbors received: 1, 8, 24, 25, 27, 29, 30, 31, 32, 33, 35 , 36, 37, 38 12:20:27.490 CNTRLR [Node 023] Interview stage completed: Neighbors 12:20:27.490 CNTRLR [Node 023] Interview completed 12:20:27.501 SERIAL « [ACK] (0x06) 12:20:27.504 SERIAL « 0x0104011301e8 (6 bytes) 12:20:27.505 SERIAL » [ACK] (0x06) 12:20:27.506 DRIVER « [RES] [SendData] was sent: true 12:20:27.575 SERIAL « 0x0107001352000008b1 (9 bytes) 12:20:27.575 SERIAL » [ACK] (0x06) 12:20:27.576 DRIVER « [REQ] [SendData] callback id: 82 transmit status: OK 12:20:27.627 SERIAL « 0x010d0004001d079c021d040000006b (15 bytes) 12:20:27.628 CNTRLR [Node 029] [~] [Alarm Sensor] state[4]: false => false [Endpoint 0] 12:20:27.629 CNTRLR [Node 029] [+] [Alarm Sensor] severity[4]: undefined [Endpoint 0] 12:20:27.630 CNTRLR [Node 029] [+] [Alarm Sensor] duration[4]: undefined [Endpoint 0] 12:20:27.631 SERIAL » [ACK] (0x06) 12:20:27.632 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: Heat alarm state: false 12:20:27.633 CNTRLR « [Node 029] received current value for Heat: state: false 12:20:27.634 CNTRLR [Node 029] [~] [Alarm Sensor] interviewComplete: true [Endpoint 0] [internal] => true 12:20:27.634 CNTRLR [Node 029] MultiChannelAssociationCC: doing a partial interview... 12:20:27.635 CNTRLR » [Node 029] querying multi channel association group #1... 12:20:27.645 SERIAL » 0x010a00131d038e0201255303 (12 bytes) 12:20:27.646 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 83 └─[MultiChannelAssociationCCGet] group id: 1 12:20:27.655 SERIAL « [ACK] (0x06) 12:20:27.657 SERIAL « 0x0104011301e8 (6 bytes) 12:20:27.658 SERIAL » [ACK] (0x06) 12:20:27.659 DRIVER « [RES] [SendData] was sent: true 12:20:27.745 SERIAL « 0x010700135300000ab2 (9 bytes) 12:20:27.745 SERIAL » [ACK] (0x06) 12:20:27.746 DRIVER « [REQ] [SendData] callback id: 83 transmit status: OK 12:20:27.796 SERIAL « 0x010b0004001d058e0301050061 (13 bytes) 12:20:27.797 SERIAL » [ACK] (0x06) 12:20:27.798 CNTRLR [Node 029] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 12:20:27.799 CNTRLR [Node 029] [~] [Multi Channel Association] nodeIds[1]: => 12:20:27.800 CNTRLR [Node 029] [~] [Multi Channel Association] endpoints[1]: => 12:20:27.801 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: endpoints: 12:20:27.802 CNTRLR « [Node 029] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 12:20:27.803 CNTRLR » [Node 029] querying multi channel association group #2... 12:20:27.807 SERIAL » 0x010a00131d038e0202255407 (12 bytes) 12:20:27.807 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 84 └─[MultiChannelAssociationCCGet] group id: 2 12:20:27.810 SERIAL « [ACK] (0x06) 12:20:27.820 SERIAL « 0x0104011301e8 (6 bytes) 12:20:27.822 SERIAL » [ACK] (0x06) 12:20:27.825 DRIVER « [RES] [SendData] was sent: true 12:20:27.916 SERIAL « 0x010700135400000ab5 (9 bytes) 12:20:27.917 SERIAL » [ACK] (0x06) 12:20:27.918 DRIVER « [REQ] [SendData] callback id: 84 transmit status: OK 12:20:27.969 SERIAL « 0x010b0004001d058e0302050062 (13 bytes) 12:20:27.969 SERIAL » [ACK] (0x06) 12:20:27.970 CNTRLR [Node 029] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 12:20:27.971 CNTRLR [Node 029] [~] [Multi Channel Association] nodeIds[2]: => 12:20:27.972 CNTRLR [Node 029] [~] [Multi Channel Association] endpoints[2]: => 12:20:27.973 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 12:20:27.975 CNTRLR « [Node 029] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 12:20:27.975 CNTRLR » [Node 029] querying additional non-multi-channel association groups... 12:20:27.975 CNTRLR » [Node 029] querying association group #3... 12:20:27.980 SERIAL » 0x010a00131d0385020325550c (12 bytes) 12:20:27.981 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 85 └─[AssociationCCGet] group id: 3 12:20:27.983 SERIAL « [ACK] (0x06) 12:20:27.992 SERIAL « 0x0104011301e8 (6 bytes) 12:20:27.993 SERIAL » [ACK] (0x06) 12:20:27.997 DRIVER « [RES] [SendData] was sent: true 12:20:28.095 SERIAL « 0x010700135500000bb5 (9 bytes) 12:20:28.096 SERIAL » [ACK] (0x06) 12:20:28.097 DRIVER « [REQ] [SendData] callback id: 85 transmit status: OK 12:20:28.147 SERIAL « 0x010c0004001d0685030301000169 (14 bytes) 12:20:28.148 SERIAL » [ACK] (0x06) 12:20:28.150 CNTRLR [Node 029] [~] [Association] maxNodes[3]: 1 => 1 [internal] 12:20:28.150 CNTRLR [Node 029] [~] [Association] nodeIds[3]: 1 => 1 [internal] 12:20:28.151 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 12:20:28.154 CNTRLR « [Node 029] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 12:20:28.155 CNTRLR [Node 029] [~] [Association] hasLifeline: true => true [internal] 12:20:28.156 CNTRLR [Node 029] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 12:20:28.177 CNTRLR [Node 029] Interview stage completed: CommandClasses 12:20:28.177 CNTRLR [Node 029] Interview stage completed: OverwriteConfig 12:20:28.178 CNTRLR » [Node 029] requesting node neighbors... 12:20:28.187 SERIAL » 0x010700801d00000065 (9 bytes) 12:20:28.188 DRIVER » [Node 029] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 12:20:28.191 SERIAL « [ACK] (0x06) 12:20:28.193 SERIAL « 0x01200180010040000000000000000000000000000000000000000000000000000 (34 bytes) 01f 12:20:28.194 SERIAL » [ACK] (0x06) 12:20:28.195 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 23 12:20:28.201 CNTRLR « [Node 029] node neighbors received: 1, 23 12:20:28.202 CNTRLR [Node 029] Interview stage completed: Neighbors 12:20:28.202 CNTRLR [Node 029] Interview completed 12:23:01.384 CNTRLR [Node 029] Beginning interview - last completed stage: None 12:23:01.385 CNTRLR [Node 029] new node, doing a full interview... 12:23:01.386 CNTRLR » [Node 029] querying protocol info... 12:23:01.469 SERIAL » 0x010400411da7 (6 bytes) 12:23:01.469 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x1d 12:23:01.475 SERIAL « [ACK] (0x06) 12:23:01.481 SERIAL « 0x01090141d39c0004a1025e (11 bytes) 12:23:01.482 SERIAL » [ACK] (0x06) 12:23:01.483 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0xd39c0004a102 12:23:01.488 CNTRLR « [Node 029] received response for protocol info: basic device class: Static Controller generic device class: Alarm Sensor specific device class: Routing Alarm Sensor is a listening device: true is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 12:23:01.488 CNTRLR [Node 029] Interview stage completed: ProtocolInfo 12:23:01.488 CNTRLR » [Node 029] pinging the node... 12:23:01.493 SERIAL » 0x010800131d010025568b (10 bytes) 12:23:01.494 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 86 └─[NoOperationCC] 12:23:01.497 SERIAL « [ACK] (0x06) 12:23:01.503 SERIAL « 0x0104011301e8 (6 bytes) 12:23:01.503 SERIAL » [ACK] (0x06) 12:23:01.505 DRIVER « [RES] [SendData] was sent: true 12:23:01.547 SERIAL « 0x0107001356000005b8 (9 bytes) 12:23:01.548 SERIAL » [ACK] (0x06) 12:23:01.549 DRIVER « [REQ] [SendData] callback id: 86 transmit status: OK 12:23:01.552 CNTRLR « [Node 029] ping successful 12:23:01.553 CNTRLR » [Node 029] querying node info... 12:23:01.567 SERIAL » 0x010400601d86 (6 bytes) 12:23:01.567 DRIVER » [Node 029] [REQ] [RequestNodeInfo] payload: 0x1d 12:23:01.570 SERIAL « [ACK] (0x06) 12:23:01.575 SERIAL « 0x01040160019b (6 bytes) 12:23:01.577 SERIAL » [ACK] (0x06) 12:23:01.578 DRIVER « [RES] [RequestNodeInfo] payload: 0x01 12:23:01.679 SERIAL « 0x01120049841d0c04a1029c31867270858e8b5669 (20 bytes) 12:23:01.681 SERIAL » [ACK] (0x06) 12:23:01.682 DRIVER « [Node 029] [REQ] [ApplicationUpdateRequest] payload: 0x841d0c04a1029c31867270858e8b56 12:23:01.688 CNTRLR « [Node 029] node info received supported CCs: · Alarm Sensor · Multilevel Sensor · Version · Manufacturer Specific · Configuration · Association · Multi Channel Association · Time Parameters · CRC-16 Encapsulation controlled CCs: 12:23:01.689 CNTRLR [Node 029] Interview stage completed: NodeInfo 12:23:01.692 CNTRLR [Node 029] ManufacturerSpecificCC: doing a complete interview... 12:23:01.693 CNTRLR » [Node 029] querying manufacturer information... 12:23:01.748 SERIAL » 0x010900131d0272042557fe (11 bytes) 12:23:01.748 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 87 └─[ManufacturerSpecificCCGet] 12:23:01.750 SERIAL « [ACK] (0x06) 12:23:01.756 SERIAL « 0x0104011301e8 (6 bytes) 12:23:01.757 SERIAL » [ACK] (0x06) 12:23:01.758 DRIVER « [RES] [SendData] was sent: true 12:23:01.802 SERIAL « 0x0107001357000005b9 (9 bytes) 12:23:01.803 SERIAL » [ACK] (0x06) 12:23:01.804 DRIVER « [REQ] [SendData] callback id: 87 transmit status: OK 12:23:01.856 SERIAL « 0x010e0004001d087205010f0c00100085 (16 bytes) 12:23:01.858 CNTRLR [Node 029] [+] [Manufacturer Specific] manufacturerId: 271 [Endpoint 0] 12:23:01.859 CNTRLR [Node 029] [+] [Manufacturer Specific] productType: 3072 [Endpoint 0] 12:23:01.861 CNTRLR [Node 029] [+] [Manufacturer Specific] productId: 4096 [Endpoint 0] 12:23:01.861 SERIAL » [ACK] (0x06) 12:23:01.863 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ManufacturerSpecificCCReport] manufacturer id: 0x010f product type: 0x0c00 product id: 0x1000 12:23:01.865 CNTRLR « [Node 029] received response for manufacturer information: manufacturer: Fibargroup (0x010f) product type: 0x0c00 product id: 0x1000 12:23:01.866 CNTRLR [Node 029] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 12:23:01.867 CNTRLR [Node 029] VersionCC: doing a complete interview... 12:23:01.867 CNTRLR » [Node 029] querying node versions... 12:23:01.905 SERIAL » 0x010900131d028611255810 (11 bytes) 12:23:01.906 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 88 └─[VersionCCGet] 12:23:01.910 SERIAL « [ACK] (0x06) 12:23:01.915 SERIAL « 0x0104011301e8 (6 bytes) 12:23:01.919 SERIAL » [ACK] (0x06) 12:23:01.921 DRIVER « [RES] [SendData] was sent: true 12:23:01.975 SERIAL « 0x0107001358000007b4 (9 bytes) 12:23:01.975 SERIAL » [ACK] (0x06) 12:23:01.976 DRIVER « [REQ] [SendData] callback id: 88 transmit status: OK 12:23:02.039 SERIAL « 0x01110004001d0b86120303430205000102052a (19 bytes) 12:23:02.041 CNTRLR [Node 029] [+] [Version] libraryType: 3 [Endpoint 0] 12:23:02.042 CNTRLR [Node 029] [+] [Version] protocolVersion: "3.67" [Endpoint 0] 12:23:02.043 CNTRLR [Node 029] [+] [Version] firmwareVersions: 2.5 [Endpoint 0] 12:23:02.043 SERIAL » [ACK] (0x06) 12:23:02.046 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[VersionCCReport] library type: Enhanced Slave protocol version: 3.67 firmware versions: 2.5 12:23:02.047 CNTRLR « [Node 029] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 3.67 firmware versions: 2.5 12:23:02.048 CNTRLR » [Node 029] querying CC versions... 12:23:02.048 CNTRLR » [Node 029] querying the CC version for Basic... 12:23:02.055 SERIAL » 0x010a00131d03861320255931 (12 bytes) 12:23:02.059 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 89 └─[VersionCCCommandClassGet] CC: Basic 12:23:02.066 SERIAL « [ACK] (0x06) 12:23:02.070 SERIAL « 0x0104011301e8 (6 bytes) 12:23:02.071 SERIAL » [ACK] (0x06) 12:23:02.072 DRIVER « [RES] [SendData] was sent: true 12:23:02.145 SERIAL « 0x0107001359000008ba (9 bytes) 12:23:02.146 SERIAL » [ACK] (0x06) 12:23:02.146 DRIVER « [REQ] [SendData] callback id: 89 transmit status: OK 12:23:02.196 SERIAL « 0x010a0004001d04861420015b (12 bytes) 12:23:02.198 SERIAL » [ACK] (0x06) 12:23:02.200 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Basic version: 1 12:23:02.202 CNTRLR [Node 029] supports CC Basic (0x20) in version 1 12:23:02.203 CNTRLR [Node 029] skipping query for Alarm Sensor (0x9c) because max implemented ve rsion is 1 12:23:02.203 CNTRLR » [Node 029] querying the CC version for Association... 12:23:02.208 SERIAL » 0x010a00131d03861385255a97 (12 bytes) 12:23:02.209 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 90 └─[VersionCCCommandClassGet] CC: Association 12:23:02.211 SERIAL « [ACK] (0x06) 12:23:02.217 SERIAL « 0x0104011301e8 (6 bytes) 12:23:02.218 SERIAL » [ACK] (0x06) 12:23:02.219 DRIVER « [RES] [SendData] was sent: true 12:23:02.315 SERIAL « 0x010700135a00000abb (9 bytes) 12:23:02.316 SERIAL » [ACK] (0x06) 12:23:02.316 DRIVER « [REQ] [SendData] callback id: 90 transmit status: OK 12:23:02.366 SERIAL « 0x010a0004001d0486148502fd (12 bytes) 12:23:02.367 SERIAL » [ACK] (0x06) 12:23:02.368 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association version: 2 12:23:02.370 CNTRLR [Node 029] supports CC Association (0x85) in version 2 12:23:02.370 CNTRLR » [Node 029] querying the CC version for Battery... 12:23:02.375 SERIAL » 0x010a00131d03861380255b93 (12 bytes) 12:23:02.376 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 91 └─[VersionCCCommandClassGet] CC: Battery 12:23:02.378 SERIAL « [ACK] (0x06) 12:23:02.384 SERIAL « 0x0104011301e8 (6 bytes) 12:23:02.385 SERIAL » [ACK] (0x06) 12:23:02.386 DRIVER « [RES] [SendData] was sent: true 12:23:02.484 SERIAL « 0x010700135b00000bbb (9 bytes) 12:23:02.485 SERIAL » [ACK] (0x06) 12:23:02.486 DRIVER « [REQ] [SendData] callback id: 91 transmit status: OK 12:23:02.536 SERIAL « 0x010a0004001d0486148001fb (12 bytes) 12:23:02.537 SERIAL » [ACK] (0x06) 12:23:02.538 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Battery version: 1 12:23:02.540 CNTRLR [Node 029] supports CC Battery (0x80) in version 1 12:23:02.543 CNTRLR » [Node 029] querying the CC version for Manufacturer Specific... 12:23:02.549 SERIAL » 0x010a00131d03861372255c66 (12 bytes) 12:23:02.550 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 92 └─[VersionCCCommandClassGet] CC: Manufacturer Specific 12:23:02.552 SERIAL « [ACK] (0x06) 12:23:02.559 SERIAL « 0x0104011301e8 (6 bytes) 12:23:02.560 SERIAL » [ACK] (0x06) 12:23:02.560 DRIVER « [RES] [SendData] was sent: true 12:23:02.665 SERIAL « 0x010700135c00000bbc (9 bytes) 12:23:02.666 SERIAL » [ACK] (0x06) 12:23:02.667 DRIVER « [REQ] [SendData] callback id: 92 transmit status: OK 12:23:02.717 SERIAL « 0x010a0004001d048614720109 (12 bytes) 12:23:02.717 SERIAL » [ACK] (0x06) 12:23:02.719 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 1 12:23:02.721 CNTRLR [Node 029] supports CC Manufacturer Specific (0x72) in version 1 12:23:02.721 CNTRLR » [Node 029] querying the CC version for Version... 12:23:02.731 SERIAL » 0x010a00131d03861386255d93 (12 bytes) 12:23:02.733 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 93 └─[VersionCCCommandClassGet] CC: Version 12:23:02.736 SERIAL « [ACK] (0x06) 12:23:02.742 SERIAL « 0x0104011301e8 (6 bytes) 12:23:02.743 SERIAL » [ACK] (0x06) 12:23:02.744 DRIVER « [RES] [SendData] was sent: true 12:23:02.835 SERIAL « 0x010700135d00000abc (9 bytes) 12:23:02.836 SERIAL » [ACK] (0x06) 12:23:02.838 DRIVER « [REQ] [SendData] callback id: 93 transmit status: OK 12:23:02.885 SERIAL « 0x010a0004001d0486148602fe (12 bytes) 12:23:02.886 SERIAL » [ACK] (0x06) 12:23:02.888 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 2 12:23:02.890 CNTRLR [Node 029] supports CC Version (0x86) in version 2 12:23:02.891 CNTRLR » [Node 029] querying the CC version for Multilevel Sensor... 12:23:02.899 SERIAL » 0x010a00131d03861331255e27 (12 bytes) 12:23:02.900 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 94 └─[VersionCCCommandClassGet] CC: Multilevel Sensor 12:23:02.903 SERIAL « [ACK] (0x06) 12:23:02.909 SERIAL « 0x0104011301e8 (6 bytes) 12:23:02.910 SERIAL » [ACK] (0x06) 12:23:02.911 DRIVER « [RES] [SendData] was sent: true 12:23:03.015 SERIAL « 0x010700135e00000bbe (9 bytes) 12:23:03.016 SERIAL » [ACK] (0x06) 12:23:03.017 DRIVER « [REQ] [SendData] callback id: 94 transmit status: OK 12:23:03.066 SERIAL « 0x010a0004001d04861431014a (12 bytes) 12:23:03.067 SERIAL » [ACK] (0x06) 12:23:03.071 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multilevel Sensor version: 1 12:23:03.073 CNTRLR [Node 029] supports CC Multilevel Sensor (0x31) in version 1 12:23:03.073 CNTRLR » [Node 029] querying the CC version for Configuration... 12:23:03.078 SERIAL » 0x010a00131d03861370255f67 (12 bytes) 12:23:03.079 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 95 └─[VersionCCCommandClassGet] CC: Configuration 12:23:03.081 SERIAL « [ACK] (0x06) 12:23:03.087 SERIAL « 0x0104011301e8 (6 bytes) 12:23:03.088 SERIAL » [ACK] (0x06) 12:23:03.088 DRIVER « [RES] [SendData] was sent: true 12:23:03.184 SERIAL « 0x010700135f00000abe (9 bytes) 12:23:03.185 SERIAL » [ACK] (0x06) 12:23:03.186 DRIVER « [REQ] [SendData] callback id: 95 transmit status: OK 12:23:03.236 SERIAL « 0x010a0004001d04861470010b (12 bytes) 12:23:03.237 SERIAL » [ACK] (0x06) 12:23:03.238 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Configuration version: 1 12:23:03.240 CNTRLR [Node 029] supports CC Configuration (0x70) in version 1 12:23:03.240 CNTRLR » [Node 029] querying the CC version for Multi Channel Association... 12:23:03.245 SERIAL » 0x010a00131d0386138e2560a6 (12 bytes) 12:23:03.245 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 96 └─[VersionCCCommandClassGet] CC: Multi Channel Association 12:23:03.247 SERIAL « [ACK] (0x06) 12:23:03.254 SERIAL « 0x0104011301e8 (6 bytes) 12:23:03.254 SERIAL » [ACK] (0x06) 12:23:03.255 DRIVER « [RES] [SendData] was sent: true 12:23:03.355 SERIAL « 0x010700136000000b80 (9 bytes) 12:23:03.355 SERIAL » [ACK] (0x06) 12:23:03.357 DRIVER « [REQ] [SendData] callback id: 96 transmit status: OK 12:23:03.407 SERIAL « 0x010a0004001d0486148e02f6 (12 bytes) 12:23:03.408 SERIAL » [ACK] (0x06) 12:23:03.409 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multi Channel Association version: 2 12:23:03.412 CNTRLR [Node 029] supports CC Multi Channel Association (0x8e) in version 2 12:23:03.412 CNTRLR [Node 029] skipping query for Time Parameters (0x8b) because max implemented version is 1 12:23:03.412 CNTRLR [Node 029] skipping query for CRC-16 Encapsulation (0x56) because max implem ented version is 1 12:23:03.413 CNTRLR [Node 029] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 12:23:03.413 CNTRLR [Node 029] trying to load device config 12:23:03.423 CNTRLR [Node 029] device config loaded 12:23:03.446 CNTRLR [Node 029] AssociationCC: doing a complete interview... 12:23:03.446 CNTRLR » [Node 029] querying number of association groups... 12:23:03.452 SERIAL » 0x010900131d02850525613e (11 bytes) 12:23:03.452 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 97 └─[AssociationCCSupportedGroupingsGet] 12:23:03.454 SERIAL « [ACK] (0x06) 12:23:03.461 SERIAL « 0x0104011301e8 (6 bytes) 12:23:03.461 SERIAL » [ACK] (0x06) 12:23:03.462 DRIVER « [RES] [SendData] was sent: true 12:23:03.524 SERIAL « 0x01070013610000078d (9 bytes) 12:23:03.525 SERIAL » [ACK] (0x06) 12:23:03.526 DRIVER « [REQ] [SendData] callback id: 97 transmit status: OK 12:23:03.576 SERIAL « 0x01090004001d038506036c (11 bytes) 12:23:03.580 CNTRLR [Node 029] [+] [Association] groupCount: 3 [Endpoint 0] [internal] 12:23:03.580 SERIAL » [ACK] (0x06) 12:23:03.581 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[AssociationCCSupportedGroupingsReport] group count: 3 12:23:03.583 CNTRLR « [Node 029] supports 3 association groups 12:23:03.584 CNTRLR [Node 029] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 12:23:03.584 CNTRLR [Node 029] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 12:23:03.585 CNTRLR [Node 029] BatteryCC: doing a complete interview... 12:23:03.585 CNTRLR » [Node 029] querying battery status... 12:23:03.591 SERIAL » 0x010900131d02800225623f (11 bytes) 12:23:03.591 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 98 └─[BatteryCCGet] 12:23:03.594 SERIAL « [ACK] (0x06) 12:23:03.600 SERIAL « 0x0104011301e8 (6 bytes) 12:23:03.601 SERIAL » [ACK] (0x06) 12:23:03.602 DRIVER « [RES] [SendData] was sent: true 12:23:03.694 SERIAL « 0x010700136200000a83 (9 bytes) 12:23:03.695 SERIAL » [ACK] (0x06) 12:23:03.697 DRIVER « [REQ] [SendData] callback id: 98 transmit status: OK 12:23:03.750 SERIAL « 0x01090004001d038003640b (11 bytes) 12:23:03.752 CNTRLR [Node 029] [+] [Battery] level: 100 [Endpoint 0] 12:23:03.754 CNTRLR [Node 029] [+] [Battery] isLow: false [Endpoint 0] 12:23:03.755 SERIAL » [ACK] (0x06) 12:23:03.758 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 12:23:03.761 CNTRLR « [Node 029] received response for battery information: level: 100 12:23:03.762 CNTRLR [Node 029] [+] [Battery] interviewComplete: true [Endpoint 0] [internal] 12:23:03.762 CNTRLR [Node 029] TimeParametersCC: doing a complete interview... 12:23:03.763 CNTRLR » [Node 029] setting current time... 12:23:03.769 SERIAL » 0x011000131d098b0107e40b0a0c17032563de (18 bytes) 12:23:03.770 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 99 └─[TimeParametersCCSet] date and time: 2020-11-10 12:23:03 12:23:03.772 SERIAL « [ACK] (0x06) 12:23:03.778 SERIAL « 0x0104011301e8 (6 bytes) 12:23:03.779 SERIAL » [ACK] (0x06) 12:23:03.780 DRIVER « [RES] [SendData] was sent: true 12:23:03.867 SERIAL « 0x010700136300000981 (9 bytes) 12:23:03.868 SERIAL » [ACK] (0x06) 12:23:03.869 DRIVER « [REQ] [SendData] callback id: 99 transmit status: OK 12:23:03.872 CNTRLR [Node 029] [+] [Time Parameters] interviewComplete: tr [Endpoint 0] [internal] ue 12:23:03.872 CNTRLR [Node 029] BasicCC: doing a complete interview... 12:23:03.873 CNTRLR » [Node 029] querying Basic CC state... 12:23:03.878 SERIAL » 0x010900131d022002256499 (11 bytes) 12:23:03.878 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 100 └─[BasicCCGet] 12:23:03.880 SERIAL « [ACK] (0x06) 12:23:03.886 SERIAL « 0x0104011301e8 (6 bytes) 12:23:03.887 SERIAL » [ACK] (0x06) 12:23:03.888 DRIVER « [RES] [SendData] was sent: true 12:23:03.932 SERIAL « 0x01070013640000058a (9 bytes) 12:23:03.933 SERIAL » [ACK] (0x06) 12:23:03.934 DRIVER « [REQ] [SendData] callback id: 100 transmit status: OK 12:23:03.984 SERIAL « 0x01090004001d03200300cf (11 bytes) 12:23:03.985 SERIAL » [ACK] (0x06) 12:23:03.986 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[BasicCCReport] current value: 0 12:23:03.988 CNTRLR « [Node 029] received Basic CC state: current value: 0 12:23:03.988 CNTRLR [Node 029] [+] [Basic] interviewComplete: true [Endpoint 0] [internal] 12:23:03.989 CNTRLR [Node 029] AlarmSensorCC: doing a complete interview... 12:23:03.990 CNTRLR » [Node 029] querying supported sensor types... 12:23:03.995 SERIAL » 0x010900131d029c03256525 (11 bytes) 12:23:03.995 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 101 └─[AlarmSensorCCSupportedGet] 12:23:03.998 SERIAL « [ACK] (0x06) 12:23:04.004 SERIAL « 0x0104011301e8 (6 bytes) 12:23:04.005 SERIAL » [ACK] (0x06) 12:23:04.006 DRIVER « [RES] [SendData] was sent: true 12:23:04.084 SERIAL « 0x010700136500000987 (9 bytes) 12:23:04.085 SERIAL » [ACK] (0x06) 12:23:04.087 DRIVER « [REQ] [SendData] callback id: 101 transmit status: OK 12:23:04.136 SERIAL « 0x010a0004001d049c04011362 (12 bytes) 12:23:04.138 CNTRLR [Node 029] [+] [Alarm Sensor] supportedSensorTypes: 0, [Endpoint 0] [internal] 1,4 12:23:04.139 CNTRLR [Node 029] [Alarm Sensor] state[0]: metadata updated [Endpoint 0] 12:23:04.140 CNTRLR [Node 029] [Alarm Sensor] severity[0]: metadata updated [Endpoint 0] 12:23:04.141 CNTRLR [Node 029] [Alarm Sensor] duration[0]: metadata updated [Endpoint 0] 12:23:04.142 CNTRLR [Node 029] [Alarm Sensor] state[1]: metadata updated [Endpoint 0] 12:23:04.142 CNTRLR [Node 029] [Alarm Sensor] severity[1]: metadata updated [Endpoint 0] 12:23:04.143 CNTRLR [Node 029] [Alarm Sensor] duration[1]: metadata updated [Endpoint 0] 12:23:04.143 CNTRLR [Node 029] [Alarm Sensor] state[4]: metadata updated [Endpoint 0] 12:23:04.144 CNTRLR [Node 029] [Alarm Sensor] severity[4]: metadata updated [Endpoint 0] 12:23:04.145 CNTRLR [Node 029] [Alarm Sensor] duration[4]: metadata updated [Endpoint 0] 12:23:04.145 SERIAL » [ACK] (0x06) 12:23:04.147 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[AlarmSensorCCSupportedReport] supported sensor types: General Purpose, Smoke, Heat 12:23:04.149 CNTRLR « [Node 029] received supported sensor types: · General Purpose · Smoke · Heat 12:23:04.150 CNTRLR » [Node 029] querying current value for General Purpose... 12:23:04.155 SERIAL » 0x010a00131d039c0100256626 (12 bytes) 12:23:04.155 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 102 └─[AlarmSensorCCGet] sensor type: General Purpose 12:23:04.171 SERIAL « [ACK] (0x06) 12:23:04.175 SERIAL « 0x0104011301e8 (6 bytes) 12:23:04.176 SERIAL » [ACK] (0x06) 12:23:04.177 DRIVER « [RES] [SendData] was sent: true 12:23:04.254 SERIAL « 0x010700136600000a87 (9 bytes) 12:23:04.255 SERIAL » [ACK] (0x06) 12:23:04.256 DRIVER « [REQ] [SendData] callback id: 102 transmit status: OK 12:23:04.308 SERIAL « 0x010d0004001d079c021d000000006f (15 bytes) 12:23:04.310 CNTRLR [Node 029] [+] [Alarm Sensor] state[0]: false [Endpoint 0] 12:23:04.313 CNTRLR [Node 029] [+] [Alarm Sensor] severity[0]: undefined [Endpoint 0] 12:23:04.314 CNTRLR [Node 029] [+] [Alarm Sensor] duration[0]: undefined [Endpoint 0] 12:23:04.314 SERIAL » [ACK] (0x06) 12:23:04.316 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: false 12:23:04.318 CNTRLR « [Node 029] received current value for General Purpose: state: false 12:23:04.318 CNTRLR » [Node 029] querying current value for Smoke... 12:23:04.333 SERIAL » 0x010a00131d039c0101256726 (12 bytes) 12:23:04.333 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 103 └─[AlarmSensorCCGet] sensor type: Smoke 12:23:04.338 SERIAL « [ACK] (0x06) 12:23:04.344 SERIAL « 0x0104011301e8 (6 bytes) 12:23:04.344 SERIAL » [ACK] (0x06) 12:23:04.348 DRIVER « [RES] [SendData] was sent: true 12:23:04.424 SERIAL « 0x010700136700000985 (9 bytes) 12:23:04.425 SERIAL » [ACK] (0x06) 12:23:04.427 DRIVER « [REQ] [SendData] callback id: 103 transmit status: OK 12:23:04.478 SERIAL « 0x010d0004001d079c021d010000006e (15 bytes) 12:23:04.480 CNTRLR [Node 029] [+] [Alarm Sensor] state[1]: false [Endpoint 0] 12:23:04.482 CNTRLR [Node 029] [+] [Alarm Sensor] severity[1]: undefined [Endpoint 0] 12:23:04.483 CNTRLR [Node 029] [+] [Alarm Sensor] duration[1]: undefined [Endpoint 0] 12:23:04.486 SERIAL » [ACK] (0x06) 12:23:04.488 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: Smoke alarm state: false 12:23:04.491 CNTRLR « [Node 029] received current value for Smoke: state: false 12:23:04.491 CNTRLR » [Node 029] querying current value for Heat... 12:23:04.500 SERIAL » 0x010a00131d039c010425682c (12 bytes) 12:23:04.501 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 104 └─[AlarmSensorCCGet] sensor type: Heat 12:23:04.508 SERIAL « [ACK] (0x06) 12:23:04.514 SERIAL « 0x0104011301e8 (6 bytes) 12:23:04.515 SERIAL » [ACK] (0x06) 12:23:04.517 DRIVER « [RES] [SendData] was sent: true 12:23:04.595 SERIAL « 0x01070013680000098a (9 bytes) 12:23:04.596 SERIAL » [ACK] (0x06) 12:23:04.597 DRIVER « [REQ] [SendData] callback id: 104 transmit status: OK 12:23:04.648 SERIAL « 0x010d0004001d079c021d040000006b (15 bytes) 12:23:04.650 CNTRLR [Node 029] [+] [Alarm Sensor] state[4]: false [Endpoint 0] 12:23:04.650 CNTRLR [Node 029] [+] [Alarm Sensor] severity[4]: undefined [Endpoint 0] 12:23:04.651 CNTRLR [Node 029] [+] [Alarm Sensor] duration[4]: undefined [Endpoint 0] 12:23:04.652 SERIAL » [ACK] (0x06) 12:23:04.657 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: Heat alarm state: false 12:23:04.659 CNTRLR « [Node 029] received current value for Heat: state: false 12:23:04.659 CNTRLR [Node 029] [+] [Alarm Sensor] interviewComplete: true [Endpoint 0] [internal] 12:23:04.681 CNTRLR [Node 029] MultilevelSensorCC: doing a complete interview... 12:23:04.682 CNTRLR » [Node 029] querying current sensor reading... 12:23:04.706 SERIAL » 0x010900131d023104256983 (11 bytes) 12:23:04.708 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 105 └─[MultilevelSensorCCGet] 12:23:04.712 SERIAL « [ACK] (0x06) 12:23:04.716 SERIAL « 0x0104011301e8 (6 bytes) 12:23:04.717 SERIAL » [ACK] (0x06) 12:23:04.718 DRIVER « [RES] [SendData] was sent: true 12:23:04.764 SERIAL « 0x010700136900000587 (9 bytes) 12:23:04.765 SERIAL » [ACK] (0x06) 12:23:04.766 DRIVER « [REQ] [SendData] callback id: 105 transmit status: OK 12:23:04.818 SERIAL « 0x010c0004001d063105012200ee15 (14 bytes) 12:23:04.821 CNTRLR [Node 029] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 12:23:04.822 CNTRLR [Node 029] [+] [Multilevel Sensor] Air temperature: 23.8 [Endpoint 0] 12:23:04.823 SERIAL » [ACK] (0x06) 12:23:04.824 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 23.8 12:23:04.826 CNTRLR « [Node 029] received current sensor reading: sensor type: Air temperature value: 23.8 °C 12:23:04.827 CNTRLR [Node 029] [+] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true 12:23:04.827 CNTRLR [Node 029] ConfigurationCC: Loading configuration parameters from device confi g 12:23:04.830 CNTRLR [Node 029] [+] [Configuration] isParamInformationFromConfig: false [internal] 12:23:04.831 CNTRLR [Node 029] [Configuration] 1: metadata updated 12:23:04.832 CNTRLR [Node 029] [Configuration] 2: metadata updated 12:23:04.834 CNTRLR [Node 029] [Configuration] 5: metadata updated 12:23:04.835 CNTRLR [Node 029] [Configuration] 7: metadata updated 12:23:04.836 CNTRLR [Node 029] [Configuration] 10: metadata updated 12:23:04.837 CNTRLR [Node 029] [Configuration] 12: metadata updated 12:23:04.838 CNTRLR [Node 029] [Configuration] 13: metadata updated 12:23:04.840 CNTRLR [Node 029] [Configuration] 73: metadata updated 12:23:04.841 CNTRLR [Node 029] [Configuration] 80: metadata updated 12:23:04.842 CNTRLR [Node 029] [Configuration] 81: metadata updated 12:23:04.843 CNTRLR [Node 029] [Configuration] 82: metadata updated 12:23:04.844 CNTRLR [Node 029] [Configuration] 83: metadata updated 12:23:04.846 CNTRLR [Node 029] [Configuration] 84: metadata updated 12:23:04.847 CNTRLR [Node 029] [Configuration] 85: metadata updated 12:23:04.848 CNTRLR [Node 029] [Configuration] 86: metadata updated 12:23:04.849 CNTRLR [Node 029] [Configuration] 87: metadata updated 12:23:04.850 CNTRLR [Node 029] [Configuration] 88: metadata updated 12:23:04.852 CNTRLR [Node 029] [Configuration] 89: metadata updated 12:23:04.853 CNTRLR [Node 029] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 12:23:04.853 CNTRLR » [Node 029] querying parameter #1 value... 12:23:04.862 SERIAL » 0x010a00131d03700501256ac3 (12 bytes) 12:23:04.863 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 106 └─[ConfigurationCCGet] parameter #: 1 12:23:04.876 SERIAL « [ACK] (0x06) 12:23:04.879 SERIAL « 0x0104011301e8 (6 bytes) 12:23:04.879 SERIAL » [ACK] (0x06) 12:23:04.892 DRIVER « [RES] [SendData] was sent: true 12:23:04.935 SERIAL « 0x010700136a00000786 (9 bytes) 12:23:04.936 SERIAL » [ACK] (0x06) 12:23:04.937 DRIVER « [REQ] [SendData] callback id: 106 transmit status: OK 12:23:04.988 SERIAL « 0x010c0004001d0670060102000099 (14 bytes) 12:23:04.995 CNTRLR [Node 029] [+] [Configuration] 1: 0 12:23:04.996 SERIAL » [ACK] (0x06) 12:23:04.997 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 2 value: 0 12:23:04.999 CNTRLR « [Node 029] parameter #1 has value: 0 12:23:04.999 CNTRLR » [Node 029] querying parameter #2 value... 12:23:05.004 SERIAL » 0x010a00131d03700502256bc1 (12 bytes) 12:23:05.004 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 107 └─[ConfigurationCCGet] parameter #: 2 12:23:05.008 SERIAL « [ACK] (0x06) 12:23:05.014 SERIAL « 0x0104011301e8 (6 bytes) 12:23:05.015 SERIAL » [ACK] (0x06) 12:23:05.016 DRIVER « [RES] [SendData] was sent: true 12:23:05.105 SERIAL « 0x010700136b00000a8a (9 bytes) 12:23:05.106 SERIAL » [ACK] (0x06) 12:23:05.107 DRIVER « [REQ] [SendData] callback id: 107 transmit status: OK 12:23:05.157 SERIAL « 0x010b0004001d0570060201039e (13 bytes) 12:23:05.161 CNTRLR [Node 029] [+] [Configuration] 2: 3 12:23:05.162 SERIAL » [ACK] (0x06) 12:23:05.164 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 3 12:23:05.165 CNTRLR « [Node 029] parameter #2 has value: 3 12:23:05.165 CNTRLR » [Node 029] querying parameter #5 value... 12:23:05.170 SERIAL » 0x010a00131d03700505256cc1 (12 bytes) 12:23:05.171 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 108 └─[ConfigurationCCGet] parameter #: 5 12:23:05.174 SERIAL « [ACK] (0x06) 12:23:05.180 SERIAL « 0x0104011301e8 (6 bytes) 12:23:05.181 SERIAL » [ACK] (0x06) 12:23:05.183 DRIVER « [RES] [SendData] was sent: true 12:23:05.284 SERIAL « 0x010700136c00000b8c (9 bytes) 12:23:05.285 SERIAL » [ACK] (0x06) 12:23:05.286 DRIVER « [REQ] [SendData] callback id: 108 transmit status: OK 12:23:05.337 SERIAL « 0x010b0004001d0570060501ff65 (13 bytes) 12:23:05.341 CNTRLR [Node 029] [+] [Configuration] 5: 255 12:23:05.342 SERIAL » [ACK] (0x06) 12:23:05.343 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 1 value: 255 12:23:05.344 CNTRLR « [Node 029] parameter #5 has value: 255 12:23:05.345 CNTRLR » [Node 029] querying parameter #7 value... 12:23:05.349 SERIAL » 0x010a00131d03700507256dc2 (12 bytes) 12:23:05.350 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 109 └─[ConfigurationCCGet] parameter #: 7 12:23:05.353 SERIAL « [ACK] (0x06) 12:23:05.359 SERIAL « 0x0104011301e8 (6 bytes) 12:23:05.360 SERIAL » [ACK] (0x06) 12:23:05.361 DRIVER « [RES] [SendData] was sent: true 12:23:05.465 SERIAL « 0x010700136d00000b8d (9 bytes) 12:23:05.466 SERIAL » [ACK] (0x06) 12:23:05.467 DRIVER « [REQ] [SendData] callback id: 109 transmit status: OK 12:23:05.517 SERIAL « 0x010b0004001d0570060701ff67 (13 bytes) 12:23:05.521 CNTRLR [Node 029] [+] [Configuration] 7: 255 12:23:05.521 SERIAL » [ACK] (0x06) 12:23:05.523 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 7 value size: 1 value: 255 12:23:05.525 CNTRLR « [Node 029] parameter #7 has value: 255 12:23:05.525 CNTRLR » [Node 029] querying parameter #10 value... 12:23:05.534 SERIAL » 0x010a00131d0370050a256ecc (12 bytes) 12:23:05.534 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 110 └─[ConfigurationCCGet] parameter #: 10 12:23:05.537 SERIAL « [ACK] (0x06) 12:23:05.544 SERIAL « 0x0104011301e8 (6 bytes) 12:23:05.545 SERIAL » [ACK] (0x06) 12:23:05.547 DRIVER « [RES] [SendData] was sent: true 12:23:05.635 SERIAL « 0x010700136e00000a8f (9 bytes) 12:23:05.635 SERIAL » [ACK] (0x06) 12:23:05.636 DRIVER « [REQ] [SendData] callback id: 110 transmit status: OK 12:23:05.688 SERIAL « 0x010c0004001d0670060a02000092 (14 bytes) 12:23:05.691 CNTRLR [Node 029] [+] [Configuration] 10: 0 12:23:05.692 SERIAL » [ACK] (0x06) 12:23:05.693 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 2 value: 0 12:23:05.698 CNTRLR « [Node 029] parameter #10 has value: 0 12:23:05.698 CNTRLR » [Node 029] querying parameter #12 value... 12:23:05.704 SERIAL » 0x010a00131d0370050c256fcb (12 bytes) 12:23:05.704 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 111 └─[ConfigurationCCGet] parameter #: 12 12:23:05.707 SERIAL « [ACK] (0x06) 12:23:05.713 SERIAL « 0x0104011301e8 (6 bytes) 12:23:05.714 SERIAL » [ACK] (0x06) 12:23:05.716 DRIVER « [RES] [SendData] was sent: true 12:23:05.805 SERIAL « 0x010700136f00000a8e (9 bytes) 12:23:05.806 SERIAL » [ACK] (0x06) 12:23:05.806 DRIVER « [REQ] [SendData] callback id: 111 transmit status: OK 12:23:05.857 SERIAL « 0x010b0004001d0570060c011487 (13 bytes) 12:23:05.861 CNTRLR [Node 029] [+] [Configuration] 12: 20 12:23:05.862 SERIAL » [ACK] (0x06) 12:23:05.863 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 1 value: 20 12:23:05.864 CNTRLR « [Node 029] parameter #12 has value: 20 12:23:05.864 CNTRLR » [Node 029] querying parameter #13 value... 12:23:05.871 SERIAL » 0x010a00131d0370050d2570d5 (12 bytes) 12:23:05.871 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 112 └─[ConfigurationCCGet] parameter #: 13 12:23:05.874 SERIAL « [ACK] (0x06) 12:23:05.881 SERIAL « 0x0104011301e8 (6 bytes) 12:23:05.882 SERIAL » [ACK] (0x06) 12:23:05.885 DRIVER « [RES] [SendData] was sent: true 12:23:05.985 SERIAL « 0x010700137000000b90 (9 bytes) 12:23:05.986 SERIAL » [ACK] (0x06) 12:23:05.988 DRIVER « [REQ] [SendData] callback id: 112 transmit status: OK 12:23:06.037 SERIAL « 0x010b0004001d0570060d010092 (13 bytes) 12:23:06.042 CNTRLR [Node 029] [+] [Configuration] 13: 0 12:23:06.043 SERIAL » [ACK] (0x06) 12:23:06.045 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 0 12:23:06.047 CNTRLR « [Node 029] parameter #13 has value: 0 12:23:06.047 CNTRLR » [Node 029] querying parameter #73 value... 12:23:06.053 SERIAL » 0x010a00131d03700549257190 (12 bytes) 12:23:06.054 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 113 └─[ConfigurationCCGet] parameter #: 73 12:23:06.058 SERIAL « [ACK] (0x06) 12:23:06.064 SERIAL « 0x0104011301e8 (6 bytes) 12:23:06.065 SERIAL » [ACK] (0x06) 12:23:06.066 DRIVER « [RES] [SendData] was sent: true 12:23:06.155 SERIAL « 0x010700137100000a90 (9 bytes) 12:23:06.161 SERIAL » [ACK] (0x06) 12:23:06.162 DRIVER « [REQ] [SendData] callback id: 113 transmit status: OK 12:23:06.210 SERIAL « 0x010c0004001d06700649020000d1 (14 bytes) 12:23:06.216 CNTRLR [Node 029] [+] [Configuration] 73: 0 12:23:06.217 SERIAL » [ACK] (0x06) 12:23:06.219 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 73 value size: 2 value: 0 12:23:06.221 CNTRLR « [Node 029] parameter #73 has value: 0 12:23:06.222 CNTRLR » [Node 029] querying parameter #80 value... 12:23:06.230 SERIAL » 0x010a00131d0370055025728a (12 bytes) 12:23:06.231 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 114 └─[ConfigurationCCGet] parameter #: 80 12:23:06.234 SERIAL « [ACK] (0x06) 12:23:06.241 SERIAL « 0x0104011301e8 (6 bytes) 12:23:06.242 SERIAL » [ACK] (0x06) 12:23:06.243 DRIVER « [RES] [SendData] was sent: true 12:23:06.325 SERIAL « 0x010700137200000990 (9 bytes) 12:23:06.325 SERIAL » [ACK] (0x06) 12:23:06.326 DRIVER « [REQ] [SendData] callback id: 114 transmit status: OK 12:23:06.377 SERIAL « 0x010b0004001d057006500101ce (13 bytes) 12:23:06.381 CNTRLR [Node 029] [+] [Configuration] 80: 1 12:23:06.382 SERIAL » [ACK] (0x06) 12:23:06.383 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 80 value size: 1 value: 1 12:23:06.385 CNTRLR « [Node 029] parameter #80 has value: 1 12:23:06.385 CNTRLR » [Node 029] querying parameter #81 value... 12:23:06.392 SERIAL » 0x010a00131d0370055125738a (12 bytes) 12:23:06.393 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 115 └─[ConfigurationCCGet] parameter #: 81 12:23:06.396 SERIAL « [ACK] (0x06) 12:23:06.403 SERIAL « 0x0104011301e8 (6 bytes) 12:23:06.404 SERIAL » [ACK] (0x06) 12:23:06.405 DRIVER « [RES] [SendData] was sent: true 12:23:06.495 SERIAL « 0x010700137300000a92 (9 bytes) 12:23:06.499 SERIAL » [ACK] (0x06) 12:23:06.500 DRIVER « [REQ] [SendData] callback id: 115 transmit status: OK 12:23:06.548 SERIAL « 0x010b0004001d057006510136f8 (13 bytes) 12:23:06.551 CNTRLR [Node 029] [+] [Configuration] 81: 54 12:23:06.553 SERIAL » [ACK] (0x06) 12:23:06.554 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 81 value size: 1 value: 54 12:23:06.556 CNTRLR « [Node 029] parameter #81 has value: 54 12:23:06.556 CNTRLR » [Node 029] querying parameter #82 value... 12:23:06.561 SERIAL » 0x010a00131d0370055225748e (12 bytes) 12:23:06.562 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 116 └─[ConfigurationCCGet] parameter #: 82 12:23:06.568 SERIAL « [ACK] (0x06) 12:23:06.571 SERIAL « 0x0104011301e8 (6 bytes) 12:23:06.572 SERIAL » [ACK] (0x06) 12:23:06.573 DRIVER « [RES] [SendData] was sent: true 12:23:06.646 SERIAL « 0x010700137400000897 (9 bytes) 12:23:06.646 SERIAL » [ACK] (0x06) 12:23:06.648 DRIVER « [REQ] [SendData] callback id: 116 transmit status: OK 12:23:06.697 SERIAL « 0x010b0004001d057006520102cf (13 bytes) 12:23:06.701 CNTRLR [Node 029] [+] [Configuration] 82: 2 12:23:06.703 SERIAL » [ACK] (0x06) 12:23:06.704 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 82 value size: 1 value: 2 12:23:06.706 CNTRLR « [Node 029] parameter #82 has value: 2 12:23:06.707 CNTRLR » [Node 029] querying parameter #83 value... 12:23:06.715 SERIAL » 0x010a00131d0370055325758e (12 bytes) 12:23:06.715 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 117 └─[ConfigurationCCGet] parameter #: 83 12:23:06.721 SERIAL « [ACK] (0x06) 12:23:06.724 SERIAL « 0x0104011301e8 (6 bytes) 12:23:06.725 SERIAL » [ACK] (0x06) 12:23:06.726 DRIVER « [RES] [SendData] was sent: true 12:23:06.815 SERIAL « 0x010700137500000a94 (9 bytes) 12:23:06.816 SERIAL » [ACK] (0x06) 12:23:06.817 DRIVER « [REQ] [SendData] callback id: 117 transmit status: OK 12:23:06.868 SERIAL « 0x010b0004001d057006530102ce (13 bytes) 12:23:06.871 CNTRLR [Node 029] [+] [Configuration] 83: 2 12:23:06.872 SERIAL » [ACK] (0x06) 12:23:06.873 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 83 value size: 1 value: 2 12:23:06.875 CNTRLR « [Node 029] parameter #83 has value: 2 12:23:06.875 CNTRLR » [Node 029] querying parameter #84 value... 12:23:06.880 SERIAL » 0x010a00131d0370055425768a (12 bytes) 12:23:06.880 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 118 └─[ConfigurationCCGet] parameter #: 84 12:23:06.886 SERIAL « [ACK] (0x06) 12:23:06.892 SERIAL « 0x0104011301e8 (6 bytes) 12:23:06.893 SERIAL » [ACK] (0x06) 12:23:06.895 DRIVER « [RES] [SendData] was sent: true 12:23:06.995 SERIAL « 0x010700137600000b96 (9 bytes) 12:23:06.997 SERIAL » [ACK] (0x06) 12:23:06.998 DRIVER « [REQ] [SendData] callback id: 118 transmit status: OK 12:23:07.048 SERIAL « 0x010b0004001d057006540132f9 (13 bytes) 12:23:07.054 CNTRLR [Node 029] [+] [Configuration] 84: 50 12:23:07.055 SERIAL » [ACK] (0x06) 12:23:07.057 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 84 value size: 1 value: 50 12:23:07.060 CNTRLR « [Node 029] parameter #84 has value: 50 12:23:07.060 CNTRLR » [Node 029] querying parameter #85 value... 12:23:07.068 SERIAL » 0x010a00131d0370055525778a (12 bytes) 12:23:07.068 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 119 └─[ConfigurationCCGet] parameter #: 85 12:23:07.073 SERIAL « [ACK] (0x06) 12:23:07.077 SERIAL « 0x0104011301e8 (6 bytes) 12:23:07.078 SERIAL » [ACK] (0x06) 12:23:07.080 DRIVER « [RES] [SendData] was sent: true 12:23:07.165 SERIAL « 0x010700137700000995 (9 bytes) 12:23:07.166 SERIAL » [ACK] (0x06) 12:23:07.166 DRIVER « [REQ] [SendData] callback id: 119 transmit status: OK 12:23:07.217 SERIAL « 0x010b0004001d057006550105cf (13 bytes) 12:23:07.220 CNTRLR [Node 029] [+] [Configuration] 85: 5 12:23:07.221 SERIAL » [ACK] (0x06) 12:23:07.223 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 85 value size: 1 value: 5 12:23:07.224 CNTRLR « [Node 029] parameter #85 has value: 5 12:23:07.225 CNTRLR » [Node 029] querying parameter #86 value... 12:23:07.230 SERIAL » 0x010a00131d03700556257886 (12 bytes) 12:23:07.230 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 120 └─[ConfigurationCCGet] parameter #: 86 12:23:07.233 SERIAL « [ACK] (0x06) 12:23:07.239 SERIAL « 0x0104011301e8 (6 bytes) 12:23:07.240 SERIAL » [ACK] (0x06) 12:23:07.241 DRIVER « [RES] [SendData] was sent: true 12:23:07.345 SERIAL « 0x010700137800000b98 (9 bytes) 12:23:07.345 SERIAL » [ACK] (0x06) 12:23:07.346 DRIVER « [REQ] [SendData] callback id: 120 transmit status: OK 12:23:07.398 SERIAL « 0x010c0004001d06700656020168a7 (14 bytes) 12:23:07.401 CNTRLR [Node 029] [+] [Configuration] 86: 360 12:23:07.402 SERIAL » [ACK] (0x06) 12:23:07.403 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 86 value size: 2 value: 360 12:23:07.413 CNTRLR « [Node 029] parameter #86 has value: 360 12:23:07.414 CNTRLR » [Node 029] querying parameter #87 value... 12:23:07.418 SERIAL » 0x010a00131d03700557257986 (12 bytes) 12:23:07.419 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 121 └─[ConfigurationCCGet] parameter #: 87 12:23:07.422 SERIAL « [ACK] (0x06) 12:23:07.427 SERIAL « 0x0104011301e8 (6 bytes) 12:23:07.428 SERIAL » [ACK] (0x06) 12:23:07.430 DRIVER « [RES] [SendData] was sent: true 12:23:07.515 SERIAL « 0x01070013790000099b (9 bytes) 12:23:07.516 SERIAL » [ACK] (0x06) 12:23:07.517 DRIVER « [REQ] [SendData] callback id: 121 transmit status: OK 12:23:07.568 SERIAL « 0x010c0004001d06700657020168a6 (14 bytes) 12:23:07.572 CNTRLR [Node 029] [+] [Configuration] 87: 360 12:23:07.573 SERIAL » [ACK] (0x06) 12:23:07.575 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 87 value size: 2 value: 360 12:23:07.576 CNTRLR « [Node 029] parameter #87 has value: 360 12:23:07.576 CNTRLR » [Node 029] querying parameter #88 value... 12:23:07.586 SERIAL » 0x010a00131d03700558257a8a (12 bytes) 12:23:07.587 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 122 └─[ConfigurationCCGet] parameter #: 88 12:23:07.599 SERIAL « [ACK] (0x06) 12:23:07.601 SERIAL « 0x0104011301e8 (6 bytes) 12:23:07.601 SERIAL » [ACK] (0x06) 12:23:07.603 DRIVER « [RES] [SendData] was sent: true 12:23:07.685 SERIAL « 0x010700137a00000998 (9 bytes) 12:23:07.686 SERIAL » [ACK] (0x06) 12:23:07.688 DRIVER « [REQ] [SendData] callback id: 122 transmit status: OK 12:23:07.738 SERIAL « 0x010b0004001d057006580100c7 (13 bytes) 12:23:07.741 CNTRLR [Node 029] [+] [Configuration] 88: 0 12:23:07.744 SERIAL » [ACK] (0x06) 12:23:07.745 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 88 value size: 1 value: 0 12:23:07.747 CNTRLR « [Node 029] parameter #88 has value: 0 12:23:07.748 CNTRLR » [Node 029] querying parameter #89 value... 12:23:07.753 SERIAL » 0x010a00131d03700559257b8a (12 bytes) 12:23:07.754 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 123 └─[ConfigurationCCGet] parameter #: 89 12:23:07.757 SERIAL « [ACK] (0x06) 12:23:07.762 SERIAL « 0x0104011301e8 (6 bytes) 12:23:07.765 SERIAL » [ACK] (0x06) 12:23:07.766 DRIVER « [RES] [SendData] was sent: true 12:23:07.855 SERIAL « 0x010700137b00000a9a (9 bytes) 12:23:07.857 SERIAL » [ACK] (0x06) 12:23:07.858 DRIVER « [REQ] [SendData] callback id: 123 transmit status: OK 12:23:07.908 SERIAL « 0x010b0004001d057006590101c7 (13 bytes) 12:23:07.913 CNTRLR [Node 029] [+] [Configuration] 89: 1 12:23:07.915 SERIAL » [ACK] (0x06) 12:23:07.916 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 89 value size: 1 value: 1 12:23:07.919 CNTRLR « [Node 029] parameter #89 has value: 1 12:23:07.920 CNTRLR [Node 029] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 12:23:07.952 CNTRLR [Node 029] MultiChannelAssociationCC: doing a complete interview... 12:23:07.953 CNTRLR » [Node 029] querying number of multi channel association groups... 12:23:07.959 SERIAL » 0x010900131d028e05257c28 (11 bytes) 12:23:07.960 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 124 └─[MultiChannelAssociationCCSupportedGroupingsGet] 12:23:07.963 SERIAL « [ACK] (0x06) 12:23:07.968 SERIAL « 0x0104011301e8 (6 bytes) 12:23:07.969 SERIAL » [ACK] (0x06) 12:23:07.970 DRIVER « [RES] [SendData] was sent: true 12:23:08.024 SERIAL « 0x010700137c00000691 (9 bytes) 12:23:08.025 SERIAL » [ACK] (0x06) 12:23:08.026 DRIVER « [REQ] [SendData] callback id: 124 transmit status: OK 12:23:08.075 SERIAL « 0x01090004001d038e060266 (11 bytes) 12:23:08.076 CNTRLR [Node 029] [+] [Multi Channel Association] groupCount: [Endpoint 0] [internal] 2 12:23:08.077 SERIAL » [ACK] (0x06) 12:23:08.078 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCSupportedGroupingsReport] group count: 2 12:23:08.080 CNTRLR « [Node 029] supports 2 multi channel association groups 12:23:08.081 CNTRLR » [Node 029] querying multi channel association group #1... 12:23:08.087 SERIAL » 0x010a00131d038e0201257d2d (12 bytes) 12:23:08.087 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 125 └─[MultiChannelAssociationCCGet] group id: 1 12:23:08.090 SERIAL « [ACK] (0x06) 12:23:08.096 SERIAL « 0x0104011301e8 (6 bytes) 12:23:08.096 SERIAL » [ACK] (0x06) 12:23:08.098 DRIVER « [RES] [SendData] was sent: true 12:23:08.195 SERIAL « 0x010700137d00000a9c (9 bytes) 12:23:08.195 SERIAL » [ACK] (0x06) 12:23:08.196 DRIVER « [REQ] [SendData] callback id: 125 transmit status: OK 12:23:08.248 SERIAL « 0x010b0004001d058e0301050061 (13 bytes) 12:23:08.249 SERIAL » [ACK] (0x06) 12:23:08.250 CNTRLR [Node 029] [+] [Multi Channel Association] maxNodes[1]: 5 12:23:08.252 CNTRLR [Node 029] [+] [Multi Channel Association] nodeIds[1]: 12:23:08.253 CNTRLR [Node 029] [+] [Multi Channel Association] endpoints[1]: 12:23:08.254 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: endpoints: 12:23:08.255 CNTRLR « [Node 029] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 12:23:08.256 CNTRLR » [Node 029] querying multi channel association group #2... 12:23:08.260 SERIAL » 0x010a00131d038e0202257e2d (12 bytes) 12:23:08.261 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 126 └─[MultiChannelAssociationCCGet] group id: 2 12:23:08.264 SERIAL « [ACK] (0x06) 12:23:08.277 SERIAL « 0x0104011301e8 (6 bytes) 12:23:08.279 SERIAL » [ACK] (0x06) 12:23:08.284 DRIVER « [RES] [SendData] was sent: true 12:23:08.375 SERIAL « 0x010700137e00000b9e (9 bytes) 12:23:08.376 SERIAL » [ACK] (0x06) 12:23:08.377 DRIVER « [REQ] [SendData] callback id: 126 transmit status: OK 12:23:08.428 SERIAL « 0x010b0004001d058e0302050062 (13 bytes) 12:23:08.429 SERIAL » [ACK] (0x06) 12:23:08.430 CNTRLR [Node 029] [+] [Multi Channel Association] maxNodes[2]: 5 12:23:08.431 CNTRLR [Node 029] [+] [Multi Channel Association] nodeIds[2]: 12:23:08.432 CNTRLR [Node 029] [+] [Multi Channel Association] endpoints[2]: 12:23:08.433 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 12:23:08.435 CNTRLR « [Node 029] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 12:23:08.435 CNTRLR » [Node 029] querying additional non-multi-channel association groups... 12:23:08.435 CNTRLR » [Node 029] querying association group #3... 12:23:08.440 SERIAL » 0x010a00131d03850203257f26 (12 bytes) 12:23:08.440 DRIVER » [Node 029] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 127 └─[AssociationCCGet] group id: 3 12:23:08.443 SERIAL « [ACK] (0x06) 12:23:08.450 SERIAL « 0x0104011301e8 (6 bytes) 12:23:08.451 SERIAL » [ACK] (0x06) 12:23:08.453 DRIVER « [RES] [SendData] was sent: true 12:23:08.555 SERIAL « 0x010700137f00000b9f (9 bytes) 12:23:08.555 SERIAL » [ACK] (0x06) 12:23:08.557 DRIVER « [REQ] [SendData] callback id: 127 transmit status: OK 12:23:08.607 SERIAL « 0x010c0004001d0685030301000169 (14 bytes) 12:23:08.608 SERIAL » [ACK] (0x06) 12:23:08.610 CNTRLR [Node 029] [+] [Association] maxNodes[3]: 1 [internal] 12:23:08.611 CNTRLR [Node 029] [+] [Association] nodeIds[3]: 1 [internal] 12:23:08.611 DRIVER « [Node 029] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 12:23:08.613 CNTRLR « [Node 029] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 12:23:08.614 CNTRLR [Node 029] [+] [Association] hasLifeline: true [internal] 12:23:08.615 CNTRLR [Node 029] [+] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true 12:23:08.626 CNTRLR [Node 029] Interview stage completed: CommandClasses 12:23:08.627 CNTRLR [Node 029] Interview stage completed: OverwriteConfig 12:23:08.627 CNTRLR » [Node 029] requesting node neighbors... 12:23:08.632 SERIAL » 0x010700801d00000065 (9 bytes) 12:23:08.633 DRIVER » [Node 029] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 12:23:08.636 SERIAL « [ACK] (0x06) 12:23:08.638 SERIAL « 0x01200180010040000000000000000000000000000000000000000000000000000 (34 bytes) 01f 12:23:08.639 SERIAL » [ACK] (0x06) 12:23:08.640 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 23 12:23:08.644 CNTRLR « [Node 029] node neighbors received: 1, 23 12:23:08.644 CNTRLR [Node 029] Interview stage completed: Neighbors 12:23:08.644 CNTRLR [Node 029] Interview completed 12:23:08.645 CNTRLR [Node 029] The node is ready to be used 12:23:27.353 CNTRLR [Node 038] Beginning interview - last completed stage: None 12:23:27.353 CNTRLR [Node 038] new node, doing a full interview... 12:23:27.354 CNTRLR » [Node 038] querying protocol info... 12:23:27.371 SERIAL » 0x01040041269c (6 bytes) 12:23:27.372 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x26 12:23:27.378 SERIAL « [ACK] (0x06) 12:23:27.380 SERIAL « 0x01090141539c0004a102de (11 bytes) 12:23:27.381 SERIAL » [ACK] (0x06) 12:23:27.383 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0x539c0004a102 12:23:27.386 CNTRLR « [Node 038] received response for protocol info: basic device class: Static Controller generic device class: Alarm Sensor specific device class: Routing Alarm Sensor is a listening device: false is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 12:23:27.388 CNTRLR [Node 038] The node is now awake. 12:23:27.398 SERIAL » 0x01090013260280022580e6 (11 bytes) 12:23:27.399 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 128 └─[BatteryCCGet] 12:23:27.401 CNTRLR [Node 038] Interview stage completed: ProtocolInfo 12:23:27.401 CNTRLR » [Node 038] pinging the node... 12:23:27.407 SERIAL « [ACK] (0x06) 12:23:27.413 SERIAL « 0x0104011301e8 (6 bytes) 12:23:27.415 SERIAL » [ACK] (0x06) 12:23:27.417 DRIVER « [RES] [SendData] was sent: true 12:23:33.788 SERIAL « 0x010700138001027e16 (9 bytes) 12:23:33.789 SERIAL » [ACK] (0x06) 12:23:33.790 DRIVER « [REQ] [SendData] callback id: 128 transmit status: NoAck 12:23:33.793 CNTRLR [Node 038] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 12:23:34.297 SERIAL » 0x01090013260280022580e6 (11 bytes) 12:23:34.298 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 128 └─[BatteryCCGet] 12:23:34.300 SERIAL « [ACK] (0x06) 12:23:34.310 SERIAL « 0x0104011301e8 (6 bytes) 12:23:34.310 SERIAL » [ACK] (0x06) 12:23:34.311 DRIVER « [RES] [SendData] was sent: true 12:23:37.389 DRIVER The awake timeout for node 38 has elapsed. Assuming it is asleep. 12:23:37.389 CNTRLR [Node 038] The node is now asleep. 12:23:37.392 CNTRLR [Node 038] ping failed: The node is asleep 12:23:37.392 CNTRLR » [Node 038] querying node info... 12:23:40.728 SERIAL « 0x0107001380010282ea (9 bytes) 12:23:40.729 SERIAL » [ACK] (0x06) 12:23:40.730 DRIVER « [REQ] [SendData] callback id: 128 transmit status: NoAck 12:26:36.746 SERIAL « 0x010d00040026079c022601ff000091 (15 bytes) 12:26:36.749 CNTRLR [Node 038] [Alarm Sensor] state[1]: metadata updated [Endpoint 0] 12:26:36.751 CNTRLR [Node 038] [Alarm Sensor] severity[1]: metadata updated [Endpoint 0] 12:26:36.752 CNTRLR [Node 038] [Alarm Sensor] duration[1]: metadata updated [Endpoint 0] 12:26:36.754 CNTRLR [Node 038] [+] [Alarm Sensor] state[1]: true [Endpoint 0] 12:26:36.755 CNTRLR [Node 038] [+] [Alarm Sensor] severity[1]: undefined [Endpoint 0] 12:26:36.757 CNTRLR [Node 038] [+] [Alarm Sensor] duration[1]: undefined [Endpoint 0] 12:26:36.758 SERIAL » [ACK] (0x06) 12:26:36.761 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: Smoke alarm state: true 12:26:37.361 SERIAL « 0x010d00040026079c0226010000006e (15 bytes) 12:26:37.362 CNTRLR [Node 038] [~] [Alarm Sensor] state[1]: true => false [Endpoint 0] 12:26:37.363 CNTRLR [Node 038] [~] [Alarm Sensor] severity[1]: undefined => undefined [Endpoint 0] 12:26:37.364 CNTRLR [Node 038] [~] [Alarm Sensor] duration[1]: undefined => undefined [Endpoint 0] 12:26:37.364 SERIAL » [ACK] (0x06) 12:26:37.366 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: Smoke alarm state: false 12:26:39.218 SERIAL « 0x010d00040026079c022600ff000090 (15 bytes) 12:26:39.219 CNTRLR [Node 038] [Alarm Sensor] state[0]: metadata updated [Endpoint 0] 12:26:39.220 CNTRLR [Node 038] [Alarm Sensor] severity[0]: metadata updated [Endpoint 0] 12:26:39.222 CNTRLR [Node 038] [Alarm Sensor] duration[0]: metadata updated [Endpoint 0] 12:26:39.222 CNTRLR [Node 038] [+] [Alarm Sensor] state[0]: true [Endpoint 0] 12:26:39.223 CNTRLR [Node 038] [+] [Alarm Sensor] severity[0]: undefined [Endpoint 0] 12:26:39.224 CNTRLR [Node 038] [+] [Alarm Sensor] duration[0]: undefined [Endpoint 0] 12:26:39.224 SERIAL » [ACK] (0x06) 12:26:39.226 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: true 12:26:59.309 SERIAL « 0x010d00040026079c0226000000006f (15 bytes) 12:26:59.311 CNTRLR [Node 038] [~] [Alarm Sensor] state[0]: true => false [Endpoint 0] 12:26:59.313 CNTRLR [Node 038] [~] [Alarm Sensor] severity[0]: undefined => undefined [Endpoint 0] 12:26:59.314 CNTRLR [Node 038] [~] [Alarm Sensor] duration[0]: undefined => undefined [Endpoint 0] 12:26:59.315 SERIAL » [ACK] (0x06) 12:26:59.318 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: false 12:27:54.355 SERIAL « 0x010d00041026079c022601ff000081 (15 bytes) 12:27:54.357 CNTRLR [Node 038] [~] [Alarm Sensor] state[1]: false => true [Endpoint 0] 12:27:54.358 CNTRLR [Node 038] [~] [Alarm Sensor] severity[1]: undefined => undefined [Endpoint 0] 12:27:54.360 CNTRLR [Node 038] [~] [Alarm Sensor] duration[1]: undefined => undefined [Endpoint 0] 12:27:54.361 SERIAL » [ACK] (0x06) 12:27:54.363 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: Smoke alarm state: true 12:27:54.473 SERIAL « 0x010d00040026079c0226010000006e (15 bytes) 12:27:54.475 CNTRLR [Node 038] [~] [Alarm Sensor] state[1]: true => false [Endpoint 0] 12:27:54.476 CNTRLR [Node 038] [~] [Alarm Sensor] severity[1]: undefined => undefined [Endpoint 0] 12:27:54.478 CNTRLR [Node 038] [~] [Alarm Sensor] duration[1]: undefined => undefined [Endpoint 0] 12:27:54.479 SERIAL » [ACK] (0x06) 12:27:54.481 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: Smoke alarm state: false 12:28:40.433 SERIAL « 0x01080004102602840744 (10 bytes) 12:28:40.435 SERIAL » [ACK] (0x06) 12:28:40.437 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 12:28:40.441 CNTRLR « [Node 038] received wakeup notification 12:28:40.443 CNTRLR [Node 038] The node is now awake. 12:28:40.454 SERIAL » 0x01090013260280022580e6 (11 bytes) 12:28:40.455 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 128 └─[BatteryCCGet] 12:28:40.459 SERIAL « [ACK] (0x06) 12:28:40.464 SERIAL « 0x0104011301e8 (6 bytes) 12:28:40.465 SERIAL » [ACK] (0x06) 12:28:40.470 DRIVER « [RES] [SendData] was sent: true 12:28:40.527 SERIAL « 0x01070013800000076c (9 bytes) 12:28:40.528 SERIAL » [ACK] (0x06) 12:28:40.529 DRIVER « [REQ] [SendData] callback id: 128 transmit status: OK 12:28:40.576 SERIAL « 0x0109000400260380036430 (11 bytes) 12:28:40.577 CNTRLR [Node 038] [+] [Battery] level: 100 [Endpoint 0] 12:28:40.578 CNTRLR [Node 038] [+] [Battery] isLow: false [Endpoint 0] 12:28:40.579 SERIAL » [ACK] (0x06) 12:28:40.581 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 12:28:40.589 SERIAL » 0x0104006026bd (6 bytes) 12:28:40.589 DRIVER » [Node 038] [REQ] [RequestNodeInfo] payload: 0x26 12:28:40.591 CNTRLR « [Node 038] received response for battery information: level: 100 12:28:40.592 CNTRLR [Node 038] [+] [Battery] interviewComplete: true [Endpoint 0] [internal] 12:28:40.619 SERIAL « [ACK] (0x06) 12:28:40.621 SERIAL « 0x01040160019b (6 bytes) 12:28:40.621 SERIAL » [ACK] (0x06) 12:28:40.625 DRIVER « [RES] [RequestNodeInfo] payload: 0x01 12:28:40.630 CNTRLR [Node 038] WakeUpCC: doing a complete interview... 12:28:40.631 CNTRLR » [Node 038] retrieving wakeup interval from the device... 12:28:40.780 SERIAL « 0x0114004984260e04a1029c31867270858e8b56848052 (22 bytes) 12:28:40.782 SERIAL » [ACK] (0x06) 12:28:40.783 DRIVER « [Node 038] [REQ] [ApplicationUpdateRequest] payload: 0x84260e04a1029c31867270858e8b568480 12:28:40.793 SERIAL » 0x01090013260284052581e4 (11 bytes) 12:28:40.794 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 129 └─[WakeUpCCIntervalGet] 12:28:40.796 CNTRLR « [Node 038] node info received supported CCs: · Alarm Sensor · Multilevel Sensor · Version · Manufacturer Specific · Configuration · Association · Multi Channel Association · Time Parameters · CRC-16 Encapsulation · Wake Up · Battery controlled CCs: 12:28:40.814 SERIAL « [ACK] (0x06) 12:28:40.821 SERIAL « 0x0104011301e8 (6 bytes) 12:28:40.822 SERIAL » [ACK] (0x06) 12:28:40.824 DRIVER « [RES] [SendData] was sent: true 12:28:40.828 CNTRLR [Node 038] Interview stage completed: NodeInfo 12:28:40.832 CNTRLR [Node 038] ManufacturerSpecificCC: doing a complete interview... 12:28:40.832 CNTRLR » [Node 038] querying manufacturer information... 12:28:40.909 SERIAL « 0x010700138100000b61 (9 bytes) 12:28:40.910 SERIAL » [ACK] (0x06) 12:28:40.911 DRIVER « [REQ] [SendData] callback id: 129 transmit status: OK 12:28:40.960 SERIAL « 0x010c00040026068406003840012c (14 bytes) 12:28:40.962 CNTRLR [Node 038] [+] [Wake Up] wakeUpInterval: 14400 [Endpoint 0] 12:28:40.963 CNTRLR [Node 038] [+] [Wake Up] controllerNodeId: 1 [Endpoint 0] 12:28:40.963 SERIAL » [ACK] (0x06) 12:28:40.965 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 14400 seconds controller node id: 1 12:28:40.969 SERIAL » 0x0109001326027204258210 (11 bytes) 12:28:40.969 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 130 └─[ManufacturerSpecificCCGet] 12:28:40.970 CNTRLR « [Node 038] received wakeup configuration: wakeup interval: 14400 seconds controller node: 1 12:28:40.971 CNTRLR [Node 038] [+] [Wake Up] interviewComplete: true [Endpoint 0] [internal] 12:28:40.972 CNTRLR [Node 038] AssociationCC: doing a complete interview... 12:28:40.972 CNTRLR » [Node 038] querying number of association groups... 12:28:40.978 SERIAL « [ACK] (0x06) 12:28:40.980 SERIAL « 0x0104011301e8 (6 bytes) 12:28:40.981 SERIAL » [ACK] (0x06) 12:28:40.982 DRIVER « [RES] [SendData] was sent: true 12:28:41.099 SERIAL « 0x010700138200000d64 (9 bytes) 12:28:41.100 SERIAL » [ACK] (0x06) 12:28:41.101 DRIVER « [REQ] [SendData] callback id: 130 transmit status: OK 12:28:41.152 SERIAL « 0x010e00040026087205010f0c001000be (16 bytes) 12:28:41.153 CNTRLR [Node 038] [+] [Manufacturer Specific] manufacturerId: 271 [Endpoint 0] 12:28:41.153 CNTRLR [Node 038] [+] [Manufacturer Specific] productType: 3072 [Endpoint 0] 12:28:41.156 CNTRLR [Node 038] [+] [Manufacturer Specific] productId: 4096 [Endpoint 0] 12:28:41.157 SERIAL » [ACK] (0x06) 12:28:41.158 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[ManufacturerSpecificCCReport] manufacturer id: 0x010f product type: 0x0c00 product id: 0x1000 12:28:41.162 SERIAL » 0x01090013260285052583e7 (11 bytes) 12:28:41.163 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 131 └─[AssociationCCSupportedGroupingsGet] 12:28:41.164 CNTRLR « [Node 038] received response for manufacturer information: manufacturer: Fibargroup (0x010f) product type: 0x0c00 product id: 0x1000 12:28:41.164 CNTRLR [Node 038] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 12:28:41.165 CNTRLR [Node 038] VersionCC: doing a complete interview... 12:28:41.165 CNTRLR » [Node 038] querying node versions... 12:28:41.170 SERIAL « [ACK] (0x06) 12:28:41.173 SERIAL « 0x0104011301e8 (6 bytes) 12:28:41.173 SERIAL » [ACK] (0x06) 12:28:41.174 DRIVER « [RES] [SendData] was sent: true 12:28:41.289 SERIAL « 0x010700138300000d65 (9 bytes) 12:28:41.290 SERIAL » [ACK] (0x06) 12:28:41.293 DRIVER « [REQ] [SendData] callback id: 131 transmit status: OK 12:28:41.338 SERIAL « 0x0109000400260385060357 (11 bytes) 12:28:41.339 CNTRLR [Node 038] [+] [Association] groupCount: 3 [Endpoint 0] [internal] 12:28:41.339 SERIAL » [ACK] (0x06) 12:28:41.340 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[AssociationCCSupportedGroupingsReport] group count: 3 12:28:41.344 SERIAL » 0x01090013260286112584f7 (11 bytes) 12:28:41.345 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 132 └─[VersionCCGet] 12:28:41.347 CNTRLR « [Node 038] supports 3 association groups 12:28:41.348 CNTRLR [Node 038] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 12:28:41.348 CNTRLR [Node 038] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 12:28:41.349 CNTRLR [Node 038] TimeParametersCC: doing a complete interview... 12:28:41.349 CNTRLR » [Node 038] setting current time... 12:28:41.353 SERIAL « [ACK] (0x06) 12:28:41.355 SERIAL « 0x0104011301e8 (6 bytes) 12:28:41.356 SERIAL » [ACK] (0x06) 12:28:41.357 DRIVER « [RES] [SendData] was sent: true 12:28:41.469 SERIAL « 0x010700138400000c63 (9 bytes) 12:28:41.470 SERIAL » [ACK] (0x06) 12:28:41.471 DRIVER « [REQ] [SendData] callback id: 132 transmit status: OK 12:28:41.523 SERIAL « 0x0111000400260b861203034302050001020511 (19 bytes) 12:28:41.525 CNTRLR [Node 038] [+] [Version] libraryType: 3 [Endpoint 0] 12:28:41.525 CNTRLR [Node 038] [+] [Version] protocolVersion: "3.67" [Endpoint 0] 12:28:41.526 CNTRLR [Node 038] [+] [Version] firmwareVersions: 2.5 [Endpoint 0] 12:28:41.526 SERIAL » [ACK] (0x06) 12:28:41.530 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[VersionCCReport] library type: Enhanced Slave protocol version: 3.67 firmware versions: 2.5 12:28:41.536 SERIAL » 0x0110001326098b0107e40b0a0c1c29258522 (18 bytes) 12:28:41.537 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 133 └─[TimeParametersCCSet] date and time: 2020-11-10 12:28:41 12:28:41.539 CNTRLR « [Node 038] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 3.67 firmware versions: 2.5 12:28:41.539 CNTRLR » [Node 038] querying CC versions... 12:28:41.539 CNTRLR » [Node 038] querying the CC version for Basic... 12:28:41.565 SERIAL « [ACK] (0x06) 12:28:41.567 SERIAL « 0x0104011301e8 (6 bytes) 12:28:41.568 SERIAL » [ACK] (0x06) 12:28:41.569 DRIVER « [RES] [SendData] was sent: true 12:28:41.664 SERIAL « 0x010700138500000c62 (9 bytes) 12:28:41.665 SERIAL » [ACK] (0x06) 12:28:41.666 DRIVER « [REQ] [SendData] callback id: 133 transmit status: OK 12:28:41.671 SERIAL » 0x010a001326038613202586d5 (12 bytes) 12:28:41.672 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 134 └─[VersionCCCommandClassGet] CC: Basic 12:28:41.673 CNTRLR [Node 038] [+] [Time Parameters] interviewComplete: tr [Endpoint 0] [internal] ue 12:28:41.684 SERIAL « [ACK] (0x06) 12:28:41.688 SERIAL « 0x0104011301e8 (6 bytes) 12:28:41.689 SERIAL » [ACK] (0x06) 12:28:41.690 DRIVER « [RES] [SendData] was sent: true 12:28:41.693 CNTRLR [Node 038] BasicCC: doing a complete interview... 12:28:41.693 CNTRLR » [Node 038] querying Basic CC state... 12:28:41.743 SERIAL « 0x01070013860000076a (9 bytes) 12:28:41.744 SERIAL » [ACK] (0x06) 12:28:41.745 DRIVER « [REQ] [SendData] callback id: 134 transmit status: OK 12:28:41.792 SERIAL « 0x010a00040026048614200160 (12 bytes) 12:28:41.793 SERIAL » [ACK] (0x06) 12:28:41.794 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Basic version: 1 12:28:41.798 SERIAL » 0x0109001326022002258741 (11 bytes) 12:28:41.799 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 135 └─[BasicCCGet] 12:28:41.800 CNTRLR [Node 038] supports CC Basic (0x20) in version 1 12:28:41.800 CNTRLR [Node 038] skipping query for Alarm Sensor (0x9c) because max implemented ve rsion is 1 12:28:41.800 CNTRLR » [Node 038] querying the CC version for Association... 12:28:41.806 SERIAL « [ACK] (0x06) 12:28:41.807 SERIAL « 0x0104011301e8 (6 bytes) 12:28:41.808 SERIAL » [ACK] (0x06) 12:28:41.809 DRIVER « [RES] [SendData] was sent: true 12:28:41.929 SERIAL « 0x010700138700000d61 (9 bytes) 12:28:41.930 SERIAL » [ACK] (0x06) 12:28:41.931 DRIVER « [REQ] [SendData] callback id: 135 transmit status: OK 12:28:41.978 SERIAL « 0x01090004002603200300f4 (11 bytes) 12:28:41.981 SERIAL » [ACK] (0x06) 12:28:41.983 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[BasicCCReport] current value: 0 12:28:41.987 SERIAL » 0x010a0013260386138525887e (12 bytes) 12:28:41.987 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 136 └─[VersionCCCommandClassGet] CC: Association 12:28:41.988 CNTRLR « [Node 038] received Basic CC state: current value: 0 12:28:41.989 CNTRLR [Node 038] [+] [Basic] interviewComplete: true [Endpoint 0] [internal] 12:28:41.999 SERIAL « [ACK] (0x06) 12:28:42.003 SERIAL « 0x0104011301e8 (6 bytes) 12:28:42.004 SERIAL » [ACK] (0x06) 12:28:42.005 DRIVER « [RES] [SendData] was sent: true 12:28:42.008 CNTRLR [Node 038] MultilevelSensorCC: doing a complete interview... 12:28:42.008 CNTRLR » [Node 038] querying current sensor reading... 12:28:42.110 SERIAL « 0x010700138800000c6f (9 bytes) 12:28:42.112 SERIAL » [ACK] (0x06) 12:28:42.113 DRIVER « [REQ] [SendData] callback id: 136 transmit status: OK 12:28:42.159 SERIAL « 0x010a000400260486148502c6 (12 bytes) 12:28:42.160 SERIAL » [ACK] (0x06) 12:28:42.163 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association version: 2 12:28:42.185 SERIAL » 0x0109001326023104258958 (11 bytes) 12:28:42.186 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 137 └─[MultilevelSensorCCGet] 12:28:42.188 CNTRLR [Node 038] supports CC Association (0x85) in version 2 12:28:42.188 CNTRLR » [Node 038] querying the CC version for Battery... 12:28:42.195 SERIAL « [ACK] (0x06) 12:28:42.198 SERIAL « 0x0104011301e8 (6 bytes) 12:28:42.199 SERIAL » [ACK] (0x06) 12:28:42.201 DRIVER « [RES] [SendData] was sent: true 12:28:42.289 SERIAL « 0x010700138900000a68 (9 bytes) 12:28:42.290 SERIAL » [ACK] (0x06) 12:28:42.296 DRIVER « [REQ] [SendData] callback id: 137 transmit status: OK 12:28:42.340 SERIAL « 0x010c00040026063105012200f131 (14 bytes) 12:28:42.342 CNTRLR [Node 038] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 12:28:42.343 CNTRLR [Node 038] [+] [Multilevel Sensor] Air temperature: 24.1 [Endpoint 0] 12:28:42.343 SERIAL » [ACK] (0x06) 12:28:42.345 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 24.1 12:28:42.349 SERIAL » 0x010a00132603861380258a79 (12 bytes) 12:28:42.349 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 138 └─[VersionCCCommandClassGet] CC: Battery 12:28:42.350 CNTRLR « [Node 038] received current sensor reading: sensor type: Air temperature value: 24.1 °C 12:28:42.351 CNTRLR [Node 038] [+] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true 12:28:42.364 SERIAL « [ACK] (0x06) 12:28:42.370 SERIAL « 0x0104011301e8 (6 bytes) 12:28:42.371 SERIAL » [ACK] (0x06) 12:28:42.373 DRIVER « [RES] [SendData] was sent: true 12:28:42.375 CNTRLR [Node 038] ConfigurationCC: skipping interview because CC version is < 3 and t here is no config file 12:28:42.375 CNTRLR [Node 038] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 12:28:42.376 CNTRLR [Node 038] AlarmSensorCC: doing a complete interview... 12:28:42.376 CNTRLR » [Node 038] querying supported sensor types... 12:28:42.480 SERIAL « 0x010700138a00000d6c (9 bytes) 12:28:42.480 SERIAL » [ACK] (0x06) 12:28:42.481 DRIVER « [REQ] [SendData] callback id: 138 transmit status: OK 12:28:42.539 SERIAL « 0x010a000400260486148001c0 (12 bytes) 12:28:42.540 SERIAL » [ACK] (0x06) 12:28:42.543 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Battery version: 1 12:28:42.549 SERIAL » 0x0109001326029c03258bf0 (11 bytes) 12:28:42.550 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 139 └─[AlarmSensorCCSupportedGet] 12:28:42.551 CNTRLR [Node 038] supports CC Battery (0x80) in version 1 12:28:42.551 CNTRLR » [Node 038] querying the CC version for Manufacturer Specific... 12:28:42.554 SERIAL « [ACK] (0x06) 12:28:42.558 SERIAL « 0x0104011301e8 (6 bytes) 12:28:42.559 SERIAL » [ACK] (0x06) 12:28:42.559 DRIVER « [RES] [SendData] was sent: true 12:28:42.659 SERIAL « 0x010700138b00000b6b (9 bytes) 12:28:42.660 SERIAL » [ACK] (0x06) 12:28:42.661 DRIVER « [REQ] [SendData] callback id: 139 transmit status: OK 12:28:42.709 SERIAL « 0x010a00040026049c04011359 (12 bytes) 12:28:42.710 CNTRLR [Node 038] [+] [Alarm Sensor] supportedSensorTypes: 0, [Endpoint 0] [internal] 1,4 12:28:42.711 CNTRLR [Node 038] [Alarm Sensor] state[4]: metadata updated [Endpoint 0] 12:28:42.712 CNTRLR [Node 038] [Alarm Sensor] severity[4]: metadata updated [Endpoint 0] 12:28:42.713 CNTRLR [Node 038] [Alarm Sensor] duration[4]: metadata updated [Endpoint 0] 12:28:42.713 SERIAL » [ACK] (0x06) 12:28:42.715 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[AlarmSensorCCSupportedReport] supported sensor types: General Purpose, Smoke, Heat 12:28:42.721 SERIAL » 0x010a00132603861372258c8d (12 bytes) 12:28:42.722 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 140 └─[VersionCCCommandClassGet] CC: Manufacturer Specific 12:28:42.723 CNTRLR « [Node 038] received supported sensor types: · General Purpose · Smoke · Heat 12:28:42.724 CNTRLR » [Node 038] querying current value for General Purpose... 12:28:42.728 SERIAL « [ACK] (0x06) 12:28:42.731 SERIAL « 0x0104011301e8 (6 bytes) 12:28:42.732 SERIAL » [ACK] (0x06) 12:28:42.732 DRIVER « [RES] [SendData] was sent: true 12:28:42.850 SERIAL « 0x010700138c00000d6a (9 bytes) 12:28:42.851 SERIAL » [ACK] (0x06) 12:28:42.852 DRIVER « [REQ] [SendData] callback id: 140 transmit status: OK 12:28:42.898 SERIAL « 0x010a00040026048614720132 (12 bytes) 12:28:42.899 SERIAL » [ACK] (0x06) 12:28:42.900 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 1 12:28:42.904 SERIAL » 0x010a001326039c0100258df6 (12 bytes) 12:28:42.905 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 141 └─[AlarmSensorCCGet] sensor type: General Purpose 12:28:42.906 CNTRLR [Node 038] supports CC Manufacturer Specific (0x72) in version 1 12:28:42.906 CNTRLR » [Node 038] querying the CC version for Version... 12:28:42.909 SERIAL « [ACK] (0x06) 12:28:42.913 SERIAL « 0x0104011301e8 (6 bytes) 12:28:42.914 SERIAL » [ACK] (0x06) 12:28:42.915 DRIVER « [RES] [SendData] was sent: true 12:28:43.030 SERIAL « 0x010700138d00000c6a (9 bytes) 12:28:43.031 SERIAL » [ACK] (0x06) 12:28:43.032 DRIVER « [REQ] [SendData] callback id: 141 transmit status: OK 12:28:43.081 SERIAL « 0x010d00040026079c0226000000006f (15 bytes) 12:28:43.083 CNTRLR [Node 038] [~] [Alarm Sensor] state[0]: false => false [Endpoint 0] 12:28:43.085 CNTRLR [Node 038] [~] [Alarm Sensor] severity[0]: undefined => undefined [Endpoint 0] 12:28:43.086 CNTRLR [Node 038] [~] [Alarm Sensor] duration[0]: undefined => undefined [Endpoint 0] 12:28:43.088 SERIAL » [ACK] (0x06) 12:28:43.091 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: false 12:28:43.099 SERIAL » 0x010a00132603861386258e7b (12 bytes) 12:28:43.100 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 142 └─[VersionCCCommandClassGet] CC: Version 12:28:43.102 CNTRLR « [Node 038] received current value for General Purpose: state: false 12:28:43.102 CNTRLR » [Node 038] querying current value for Smoke... 12:28:43.120 SERIAL « [ACK] (0x06) 12:28:43.123 SERIAL « 0x0104011301e8 (6 bytes) 12:28:43.123 SERIAL » [ACK] (0x06) 12:28:43.127 DRIVER « [RES] [SendData] was sent: true 12:28:43.220 SERIAL « 0x010700138e00000c69 (9 bytes) 12:28:43.220 SERIAL » [ACK] (0x06) 12:28:43.221 DRIVER « [REQ] [SendData] callback id: 142 transmit status: OK 12:28:43.269 SERIAL « 0x010a000400260486148602c5 (12 bytes) 12:28:43.269 SERIAL » [ACK] (0x06) 12:28:43.270 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 2 12:28:43.276 SERIAL » 0x010a001326039c0101258ff5 (12 bytes) 12:28:43.277 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 143 └─[AlarmSensorCCGet] sensor type: Smoke 12:28:43.277 CNTRLR [Node 038] supports CC Version (0x86) in version 2 12:28:43.278 CNTRLR » [Node 038] querying the CC version for Wake Up... 12:28:43.286 SERIAL « [ACK] (0x06) 12:28:43.287 SERIAL « 0x0104011301e8 (6 bytes) 12:28:43.287 SERIAL » [ACK] (0x06) 12:28:43.288 DRIVER « [RES] [SendData] was sent: true 12:28:43.400 SERIAL « 0x010700138f00000c68 (9 bytes) 12:28:43.400 SERIAL » [ACK] (0x06) 12:28:43.401 DRIVER « [REQ] [SendData] callback id: 143 transmit status: OK 12:28:43.451 SERIAL « 0x010d00040026079c0226010000006e (15 bytes) 12:28:43.452 CNTRLR [Node 038] [~] [Alarm Sensor] state[1]: false => false [Endpoint 0] 12:28:43.453 CNTRLR [Node 038] [~] [Alarm Sensor] severity[1]: undefined => undefined [Endpoint 0] 12:28:43.453 CNTRLR [Node 038] [~] [Alarm Sensor] duration[1]: undefined => undefined [Endpoint 0] 12:28:43.454 SERIAL » [ACK] (0x06) 12:28:43.455 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: Smoke alarm state: false 12:28:43.460 SERIAL » 0x010a00132603861384259067 (12 bytes) 12:28:43.461 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 144 └─[VersionCCCommandClassGet] CC: Wake Up 12:28:43.462 CNTRLR « [Node 038] received current value for Smoke: state: false 12:28:43.462 CNTRLR » [Node 038] querying current value for Heat... 12:28:43.466 SERIAL « [ACK] (0x06) 12:28:43.470 SERIAL « 0x0104011301e8 (6 bytes) 12:28:43.470 SERIAL » [ACK] (0x06) 12:28:43.471 DRIVER « [RES] [SendData] was sent: true 12:28:43.590 SERIAL « 0x010700139000000d76 (9 bytes) 12:28:43.590 SERIAL » [ACK] (0x06) 12:28:43.591 DRIVER « [REQ] [SendData] callback id: 144 transmit status: OK 12:28:43.639 SERIAL « 0x010a000400260486148401c4 (12 bytes) 12:28:43.639 SERIAL » [ACK] (0x06) 12:28:43.641 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Wake Up version: 1 12:28:43.645 SERIAL » 0x010a001326039c01042591ee (12 bytes) 12:28:43.645 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 145 └─[AlarmSensorCCGet] sensor type: Heat 12:28:43.647 CNTRLR [Node 038] supports CC Wake Up (0x84) in version 1 12:28:43.647 CNTRLR » [Node 038] querying the CC version for Multilevel Sensor... 12:28:43.651 SERIAL « [ACK] (0x06) 12:28:43.654 SERIAL « 0x0104011301e8 (6 bytes) 12:28:43.655 SERIAL » [ACK] (0x06) 12:28:43.656 DRIVER « [RES] [SendData] was sent: true 12:28:43.770 SERIAL « 0x010700139100000c76 (9 bytes) 12:28:43.771 SERIAL » [ACK] (0x06) 12:28:43.772 DRIVER « [REQ] [SendData] callback id: 145 transmit status: OK 12:28:43.821 SERIAL « 0x010d00040026079c0226040000006b (15 bytes) 12:28:43.822 CNTRLR [Node 038] [+] [Alarm Sensor] state[4]: false [Endpoint 0] 12:28:43.823 CNTRLR [Node 038] [+] [Alarm Sensor] severity[4]: undefined [Endpoint 0] 12:28:43.823 CNTRLR [Node 038] [+] [Alarm Sensor] duration[4]: undefined [Endpoint 0] 12:28:43.824 SERIAL » [ACK] (0x06) 12:28:43.830 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: Heat alarm state: false 12:28:43.836 SERIAL » 0x010a001326038613312592d0 (12 bytes) 12:28:43.837 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 146 └─[VersionCCCommandClassGet] CC: Multilevel Sensor 12:28:43.839 CNTRLR « [Node 038] received current value for Heat: state: false 12:28:43.839 CNTRLR [Node 038] [+] [Alarm Sensor] interviewComplete: true [Endpoint 0] [internal] 12:28:43.866 SERIAL « [ACK] (0x06) 12:28:43.873 SERIAL « 0x0104011301e8 (6 bytes) 12:28:43.874 SERIAL » [ACK] (0x06) 12:28:43.879 DRIVER « [RES] [SendData] was sent: true 12:28:43.884 CNTRLR [Node 038] MultiChannelAssociationCC: doing a complete interview... 12:28:43.885 CNTRLR » [Node 038] querying number of multi channel association groups... 12:28:43.960 SERIAL « 0x010700139200000c75 (9 bytes) 12:28:43.961 SERIAL » [ACK] (0x06) 12:28:43.962 DRIVER « [REQ] [SendData] callback id: 146 transmit status: OK 12:28:44.009 SERIAL « 0x010a00040026048614310171 (12 bytes) 12:28:44.010 SERIAL » [ACK] (0x06) 12:28:44.012 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multilevel Sensor version: 1 12:28:44.018 SERIAL » 0x0109001326028e052593fc (11 bytes) 12:28:44.019 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 147 └─[MultiChannelAssociationCCSupportedGroupingsGet] 12:28:44.021 CNTRLR [Node 038] supports CC Multilevel Sensor (0x31) in version 1 12:28:44.021 CNTRLR » [Node 038] querying the CC version for Configuration... 12:28:44.025 SERIAL « [ACK] (0x06) 12:28:44.028 SERIAL « 0x0104011301e8 (6 bytes) 12:28:44.029 SERIAL » [ACK] (0x06) 12:28:44.030 DRIVER « [RES] [SendData] was sent: true 12:28:44.149 SERIAL « 0x010700139300000d75 (9 bytes) 12:28:44.150 SERIAL » [ACK] (0x06) 12:28:44.151 DRIVER « [REQ] [SendData] callback id: 147 transmit status: OK 12:28:44.198 SERIAL « 0x010900040026038e06025d (11 bytes) 12:28:44.199 CNTRLR [Node 038] [+] [Multi Channel Association] groupCount: [Endpoint 0] [internal] 2 12:28:44.199 SERIAL » [ACK] (0x06) 12:28:44.201 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCSupportedGroupingsReport] group count: 2 12:28:44.204 SERIAL » 0x010a00132603861370259497 (12 bytes) 12:28:44.205 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 148 └─[VersionCCCommandClassGet] CC: Configuration 12:28:44.206 CNTRLR « [Node 038] supports 2 multi channel association groups 12:28:44.206 CNTRLR » [Node 038] querying multi channel association group #1... 12:28:44.210 SERIAL « [ACK] (0x06) 12:28:44.213 SERIAL « 0x0104011301e8 (6 bytes) 12:28:44.214 SERIAL » [ACK] (0x06) 12:28:44.215 DRIVER « [RES] [SendData] was sent: true 12:28:44.330 SERIAL « 0x010700139400000c73 (9 bytes) 12:28:44.331 SERIAL » [ACK] (0x06) 12:28:44.332 DRIVER « [REQ] [SendData] callback id: 148 transmit status: OK 12:28:44.379 SERIAL « 0x010a00040026048614700130 (12 bytes) 12:28:44.380 SERIAL » [ACK] (0x06) 12:28:44.383 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Configuration version: 1 12:28:44.387 SERIAL » 0x010a001326038e02012595fe (12 bytes) 12:28:44.387 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 149 └─[MultiChannelAssociationCCGet] group id: 1 12:28:44.388 CNTRLR [Node 038] supports CC Configuration (0x70) in version 1 12:28:44.388 CNTRLR » [Node 038] querying the CC version for Multi Channel Association... 12:28:44.392 SERIAL « [ACK] (0x06) 12:28:44.396 SERIAL « 0x0104011301e8 (6 bytes) 12:28:44.396 SERIAL » [ACK] (0x06) 12:28:44.397 DRIVER « [RES] [SendData] was sent: true 12:28:44.510 SERIAL « 0x010700139500000c72 (9 bytes) 12:28:44.510 SERIAL » [ACK] (0x06) 12:28:44.511 DRIVER « [REQ] [SendData] callback id: 149 transmit status: OK 12:28:44.560 SERIAL « 0x010b00040026058e030105005a (13 bytes) 12:28:44.561 SERIAL » [ACK] (0x06) 12:28:44.562 CNTRLR [Node 038] [+] [Multi Channel Association] maxNodes[1]: 5 12:28:44.563 CNTRLR [Node 038] [+] [Multi Channel Association] nodeIds[1]: 12:28:44.564 CNTRLR [Node 038] [+] [Multi Channel Association] endpoints[1]: 12:28:44.565 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: endpoints: 12:28:44.569 SERIAL » 0x010a0013260386138e25966b (12 bytes) 12:28:44.570 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 150 └─[VersionCCCommandClassGet] CC: Multi Channel Association 12:28:44.571 CNTRLR « [Node 038] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 12:28:44.571 CNTRLR » [Node 038] querying multi channel association group #2... 12:28:44.575 SERIAL « [ACK] (0x06) 12:28:44.578 SERIAL « 0x0104011301e8 (6 bytes) 12:28:44.579 SERIAL » [ACK] (0x06) 12:28:44.583 DRIVER « [RES] [SendData] was sent: true 12:28:44.700 SERIAL « 0x010700139600000d70 (9 bytes) 12:28:44.701 SERIAL » [ACK] (0x06) 12:28:44.703 DRIVER « [REQ] [SendData] callback id: 150 transmit status: OK 12:28:44.751 SERIAL « 0x010a000400260486148e02cd (12 bytes) 12:28:44.752 SERIAL » [ACK] (0x06) 12:28:44.753 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multi Channel Association version: 2 12:28:44.758 SERIAL » 0x010a001326038e02022597ff (12 bytes) 12:28:44.759 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 151 └─[MultiChannelAssociationCCGet] group id: 2 12:28:44.761 CNTRLR [Node 038] supports CC Multi Channel Association (0x8e) in version 2 12:28:44.763 CNTRLR [Node 038] skipping query for Time Parameters (0x8b) because max implemented version is 1 12:28:44.763 CNTRLR [Node 038] skipping query for CRC-16 Encapsulation (0x56) because max implem ented version is 1 12:28:44.764 CNTRLR [Node 038] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 12:28:44.769 CNTRLR [Node 038] trying to load device config 12:28:44.779 SERIAL « [ACK] (0x06) 12:28:44.782 SERIAL « 0x0104011301e8 (6 bytes) 12:28:44.783 SERIAL » [ACK] (0x06) 12:28:44.784 DRIVER « [RES] [SendData] was sent: true 12:28:44.796 CNTRLR [Node 038] device config loaded 12:28:44.810 CNTRLR [Node 038] AssociationCC: doing a partial interview... 12:28:44.810 CNTRLR [Node 038] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 12:28:44.811 CNTRLR [Node 038] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 12:28:44.812 CNTRLR [Node 038] BatteryCC: doing a partial interview... 12:28:44.813 CNTRLR » [Node 038] querying battery status... 12:28:44.890 SERIAL « 0x010700139700000d71 (9 bytes) 12:28:44.891 SERIAL » [ACK] (0x06) 12:28:44.892 DRIVER « [REQ] [SendData] callback id: 151 transmit status: OK 12:28:44.940 SERIAL « 0x010b00040026058e0302050059 (13 bytes) 12:28:44.940 SERIAL » [ACK] (0x06) 12:28:44.941 CNTRLR [Node 038] [+] [Multi Channel Association] maxNodes[2]: 5 12:28:44.942 CNTRLR [Node 038] [+] [Multi Channel Association] nodeIds[2]: 12:28:44.943 CNTRLR [Node 038] [+] [Multi Channel Association] endpoints[2]: 12:28:44.945 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 12:28:44.948 SERIAL » 0x01090013260280022598fe (11 bytes) 12:28:44.949 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 152 └─[BatteryCCGet] 12:28:44.950 CNTRLR « [Node 038] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 12:28:44.950 CNTRLR » [Node 038] querying additional non-multi-channel association groups... 12:28:44.950 CNTRLR » [Node 038] querying association group #3... 12:28:44.955 SERIAL « [ACK] (0x06) 12:28:44.958 SERIAL « 0x0104011301e8 (6 bytes) 12:28:44.958 SERIAL » [ACK] (0x06) 12:28:44.959 DRIVER « [RES] [SendData] was sent: true 12:28:45.079 SERIAL « 0x010700139800000d7e (9 bytes) 12:28:45.080 SERIAL » [ACK] (0x06) 12:28:45.081 DRIVER « [REQ] [SendData] callback id: 152 transmit status: OK 12:28:45.128 SERIAL « 0x0109000400260380036430 (11 bytes) 12:28:45.130 CNTRLR [Node 038] [~] [Battery] level: 100 => 100 [Endpoint 0] 12:28:45.130 CNTRLR [Node 038] [~] [Battery] isLow: false => false [Endpoint 0] 12:28:45.131 SERIAL » [ACK] (0x06) 12:28:45.133 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 12:28:45.136 SERIAL » 0x010a001326038502032599fb (12 bytes) 12:28:45.137 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 153 └─[AssociationCCGet] group id: 3 12:28:45.138 CNTRLR « [Node 038] received response for battery information: level: 100 12:28:45.138 CNTRLR [Node 038] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:28:45.152 SERIAL « [ACK] (0x06) 12:28:45.155 SERIAL « 0x0104011301e8 (6 bytes) 12:28:45.155 SERIAL » [ACK] (0x06) 12:28:45.156 DRIVER « [RES] [SendData] was sent: true 12:28:45.159 CNTRLR [Node 038] WakeUpCC: doing a partial interview... 12:28:45.160 CNTRLR » [Node 038] retrieving wakeup interval from the device... 12:28:45.260 SERIAL « 0x010700139900000c7e (9 bytes) 12:28:45.261 SERIAL » [ACK] (0x06) 12:28:45.262 DRIVER « [REQ] [SendData] callback id: 153 transmit status: OK 12:28:46.865 CNTRLR [Node 038] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 12:28:47.368 SERIAL » 0x010a001326038502032599fb (12 bytes) 12:28:47.370 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 153 └─[AssociationCCGet] group id: 3 12:28:47.371 SERIAL « [ACK] (0x06) 12:28:47.378 SERIAL « 0x0104011301e8 (6 bytes) 12:28:47.379 SERIAL » [ACK] (0x06) 12:28:47.381 DRIVER « [RES] [SendData] was sent: true 12:28:47.440 SERIAL « 0x010700139900000775 (9 bytes) 12:28:47.441 SERIAL » [ACK] (0x06) 12:28:47.442 DRIVER « [REQ] [SendData] callback id: 153 transmit status: OK 12:28:47.491 SERIAL « 0x010c000400260685030301000152 (14 bytes) 12:28:47.492 SERIAL » [ACK] (0x06) 12:28:47.494 CNTRLR [Node 038] [+] [Association] maxNodes[3]: 1 [internal] 12:28:47.495 CNTRLR [Node 038] [+] [Association] nodeIds[3]: 1 [internal] 12:28:47.496 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 12:28:47.502 SERIAL » 0x0109001326028405259aff (11 bytes) 12:28:47.503 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 154 └─[WakeUpCCIntervalGet] 12:28:47.504 CNTRLR « [Node 038] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 12:28:47.505 CNTRLR [Node 038] [+] [Association] hasLifeline: true [internal] 12:28:47.515 CNTRLR [Node 038] [+] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true 12:28:47.533 SERIAL « [ACK] (0x06) 12:28:47.535 SERIAL « 0x0104011301e8 (6 bytes) 12:28:47.535 SERIAL » [ACK] (0x06) 12:28:47.538 DRIVER « [RES] [SendData] was sent: true 12:28:47.543 CNTRLR [Node 038] Interview stage completed: CommandClasses 12:28:47.544 CNTRLR [Node 038] Interview stage completed: OverwriteConfig 12:28:47.544 CNTRLR » [Node 038] requesting node neighbors... 12:28:47.630 SERIAL « 0x010700139a00000d7c (9 bytes) 12:28:47.630 SERIAL » [ACK] (0x06) 12:28:47.631 DRIVER « [REQ] [SendData] callback id: 154 transmit status: OK 12:28:47.680 SERIAL « 0x010c00040026068406003840012c (14 bytes) 12:28:47.682 CNTRLR [Node 038] [~] [Wake Up] wakeUpInterval: 14400 => 14400 [Endpoint 0] 12:28:47.682 CNTRLR [Node 038] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 12:28:47.683 SERIAL » [ACK] (0x06) 12:28:47.686 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 14400 seconds controller node id: 1 12:28:47.690 SERIAL » 0x01070080260000005e (9 bytes) 12:28:47.691 DRIVER » [Node 038] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 12:28:47.692 CNTRLR « [Node 038] received wakeup configuration: wakeup interval: 14400 seconds controller node: 1 12:28:47.693 CNTRLR [Node 038] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:28:47.704 SERIAL « [ACK] (0x06) 12:28:47.706 SERIAL « 0x01200180810040000000000000000000000000000000000000000000000000000 (34 bytes) 09f 12:28:47.707 SERIAL » [ACK] (0x06) 12:28:47.709 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 8, 23 12:28:47.715 CNTRLR « [Node 038] node neighbors received: 1, 8, 23 12:28:47.715 CNTRLR [Node 038] Interview stage completed: Neighbors 12:28:47.715 CNTRLR [Node 038] Interview completed 12:28:47.716 CNTRLR [Node 038] The node is ready to be used 12:28:47.719 CNTRLR [Node 038] TimeParametersCC: doing a partial interview... 12:28:47.719 CNTRLR » [Node 038] setting current time... 12:28:47.724 SERIAL » 0x0110001326098b0107e40b0a0c1c2f259b3a (18 bytes) 12:28:47.725 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 155 └─[TimeParametersCCSet] date and time: 2020-11-10 12:28:47 12:28:47.727 SERIAL « [ACK] (0x06) 12:28:47.846 SERIAL « 0x0104011301e8 (6 bytes) 12:28:47.846 SERIAL » [ACK] (0x06) 12:28:47.847 DRIVER « [RES] [SendData] was sent: true 12:28:47.850 SERIAL « 0x010700139b00000979 (9 bytes) 12:28:47.850 SERIAL » [ACK] (0x06) 12:28:47.851 DRIVER « [REQ] [SendData] callback id: 155 transmit status: OK 12:28:47.854 CNTRLR [Node 038] [~] [Time Parameters] interviewComplete: tr [Endpoint 0] [internal] ue => true 12:28:47.857 CNTRLR [Node 038] BasicCC: doing a partial interview... 12:28:47.857 CNTRLR » [Node 038] querying Basic CC state... 12:28:47.862 SERIAL » 0x0109001326022002259c5a (11 bytes) 12:28:47.863 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 156 └─[BasicCCGet] 12:28:47.865 SERIAL « [ACK] (0x06) 12:28:47.871 SERIAL « 0x0104011301e8 (6 bytes) 12:28:47.871 SERIAL » [ACK] (0x06) 12:28:47.872 DRIVER « [RES] [SendData] was sent: true 12:28:47.934 SERIAL « 0x010700139c00000770 (9 bytes) 12:28:47.934 SERIAL » [ACK] (0x06) 12:28:47.935 DRIVER « [REQ] [SendData] callback id: 156 transmit status: OK 12:28:47.981 SERIAL « 0x01090004002603200300f4 (11 bytes) 12:28:47.982 SERIAL » [ACK] (0x06) 12:28:47.983 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[BasicCCReport] current value: 0 12:28:47.985 CNTRLR « [Node 038] received Basic CC state: current value: 0 12:28:47.985 CNTRLR [Node 038] [~] [Basic] interviewComplete: true => true [Endpoint 0] [internal] 12:28:48.001 CNTRLR [Node 038] AlarmSensorCC: doing a partial interview... 12:28:48.001 CNTRLR » [Node 038] querying current value for General Purpose... 12:28:48.006 SERIAL » 0x010a001326039c0100259de6 (12 bytes) 12:28:48.006 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 157 └─[AlarmSensorCCGet] sensor type: General Purpose 12:28:48.010 SERIAL « [ACK] (0x06) 12:28:48.014 SERIAL « 0x0104011301e8 (6 bytes) 12:28:48.015 SERIAL » [ACK] (0x06) 12:28:48.016 DRIVER « [RES] [SendData] was sent: true 12:28:48.120 SERIAL « 0x010700139d00000b7d (9 bytes) 12:28:48.121 SERIAL » [ACK] (0x06) 12:28:48.121 DRIVER « [REQ] [SendData] callback id: 157 transmit status: OK 12:28:48.174 SERIAL « 0x010d00040026079c0226000000006f (15 bytes) 12:28:48.176 CNTRLR [Node 038] [~] [Alarm Sensor] state[0]: false => false [Endpoint 0] 12:28:48.177 CNTRLR [Node 038] [~] [Alarm Sensor] severity[0]: undefined => undefined [Endpoint 0] 12:28:48.178 CNTRLR [Node 038] [~] [Alarm Sensor] duration[0]: undefined => undefined [Endpoint 0] 12:28:48.179 SERIAL » [ACK] (0x06) 12:28:48.180 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: false 12:28:48.182 CNTRLR « [Node 038] received current value for General Purpose: state: false 12:28:48.183 CNTRLR » [Node 038] querying current value for Smoke... 12:28:48.187 SERIAL » 0x010a001326039c0101259ee4 (12 bytes) 12:28:48.188 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 158 └─[AlarmSensorCCGet] sensor type: Smoke 12:28:48.193 SERIAL « [ACK] (0x06) 12:28:48.199 SERIAL « 0x0104011301e8 (6 bytes) 12:28:48.199 SERIAL » [ACK] (0x06) 12:28:48.200 DRIVER « [RES] [SendData] was sent: true 12:28:48.311 SERIAL « 0x010700139e00000c79 (9 bytes) 12:28:48.312 SERIAL » [ACK] (0x06) 12:28:48.313 DRIVER « [REQ] [SendData] callback id: 158 transmit status: OK 12:28:48.362 SERIAL « 0x010d00040026079c0226010000006e (15 bytes) 12:28:48.363 CNTRLR [Node 038] [~] [Alarm Sensor] state[1]: false => false [Endpoint 0] 12:28:48.365 CNTRLR [Node 038] [~] [Alarm Sensor] severity[1]: undefined => undefined [Endpoint 0] 12:28:48.366 CNTRLR [Node 038] [~] [Alarm Sensor] duration[1]: undefined => undefined [Endpoint 0] 12:28:48.367 SERIAL » [ACK] (0x06) 12:28:48.369 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: Smoke alarm state: false 12:28:48.371 CNTRLR « [Node 038] received current value for Smoke: state: false 12:28:48.372 CNTRLR » [Node 038] querying current value for Heat... 12:28:48.378 SERIAL » 0x010a001326039c0104259fe0 (12 bytes) 12:28:48.378 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 159 └─[AlarmSensorCCGet] sensor type: Heat 12:28:48.385 SERIAL « [ACK] (0x06) 12:28:48.392 SERIAL « 0x0104011301e8 (6 bytes) 12:28:48.392 SERIAL » [ACK] (0x06) 12:28:48.394 DRIVER « [RES] [SendData] was sent: true 12:28:48.500 SERIAL « 0x010700139f00000c78 (9 bytes) 12:28:48.500 SERIAL » [ACK] (0x06) 12:28:48.501 DRIVER « [REQ] [SendData] callback id: 159 transmit status: OK 12:28:48.551 SERIAL « 0x010d00040026079c0226040000006b (15 bytes) 12:28:48.552 CNTRLR [Node 038] [~] [Alarm Sensor] state[4]: false => false [Endpoint 0] 12:28:48.553 CNTRLR [Node 038] [~] [Alarm Sensor] severity[4]: undefined => undefined [Endpoint 0] 12:28:48.554 CNTRLR [Node 038] [~] [Alarm Sensor] duration[4]: undefined => undefined [Endpoint 0] 12:28:48.554 SERIAL » [ACK] (0x06) 12:28:48.556 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: Heat alarm state: false 12:28:48.557 CNTRLR « [Node 038] received current value for Heat: state: false 12:28:48.558 CNTRLR [Node 038] [~] [Alarm Sensor] interviewComplete: true [Endpoint 0] [internal] => true 12:28:48.571 CNTRLR [Node 038] MultilevelSensorCC: doing a partial interview... 12:28:48.571 CNTRLR » [Node 038] querying current sensor reading... 12:28:48.576 SERIAL » 0x010900132602310425a071 (11 bytes) 12:28:48.577 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 160 └─[MultilevelSensorCCGet] 12:28:48.578 SERIAL « [ACK] (0x06) 12:28:48.585 SERIAL « 0x0104011301e8 (6 bytes) 12:28:48.586 SERIAL » [ACK] (0x06) 12:28:48.587 DRIVER « [RES] [SendData] was sent: true 12:28:48.700 SERIAL « 0x01070013a000000b40 (9 bytes) 12:28:48.701 SERIAL » [ACK] (0x06) 12:28:48.702 DRIVER « [REQ] [SendData] callback id: 160 transmit status: OK 12:28:48.741 SERIAL « 0x010c00040026063105012200f131 (14 bytes) 12:28:48.743 CNTRLR [Node 038] [Multilevel Sensor] Air temperature: metadata updated [Endpoint 0] 12:28:48.744 CNTRLR [Node 038] [~] [Multilevel Sensor] Air temperature: 24.1 => 24.1 [Endpoint 0] 12:28:48.745 SERIAL » [ACK] (0x06) 12:28:48.747 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Air temperature scale: Celsius value: 24.1 12:28:48.750 CNTRLR « [Node 038] received current sensor reading: sensor type: Air temperature value: 24.1 °C 12:28:48.751 CNTRLR [Node 038] [~] [Multilevel Sensor] interviewComplete: [Endpoint 0] [internal] true => true 12:28:48.782 CNTRLR [Node 038] ConfigurationCC: Loading configuration parameters from device confi g 12:28:48.785 CNTRLR [Node 038] [+] [Configuration] isParamInformationFromConfig: false [internal] 12:28:48.786 CNTRLR [Node 038] [Configuration] 1: metadata updated 12:28:48.797 CNTRLR [Node 038] [Configuration] 2: metadata updated 12:28:48.799 CNTRLR [Node 038] [Configuration] 5: metadata updated 12:28:48.800 CNTRLR [Node 038] [Configuration] 7: metadata updated 12:28:48.802 CNTRLR [Node 038] [Configuration] 10: metadata updated 12:28:48.803 CNTRLR [Node 038] [Configuration] 12: metadata updated 12:28:48.805 CNTRLR [Node 038] [Configuration] 13: metadata updated 12:28:48.806 CNTRLR [Node 038] [Configuration] 73: metadata updated 12:28:48.808 CNTRLR [Node 038] [Configuration] 80: metadata updated 12:28:48.810 CNTRLR [Node 038] [Configuration] 81: metadata updated 12:28:48.813 CNTRLR [Node 038] [Configuration] 82: metadata updated 12:28:48.825 CNTRLR [Node 038] [Configuration] 83: metadata updated 12:28:48.829 CNTRLR [Node 038] [Configuration] 84: metadata updated 12:28:48.831 CNTRLR [Node 038] [Configuration] 85: metadata updated 12:28:48.834 CNTRLR [Node 038] [Configuration] 86: metadata updated 12:28:48.836 CNTRLR [Node 038] [Configuration] 87: metadata updated 12:28:48.837 CNTRLR [Node 038] [Configuration] 88: metadata updated 12:28:48.839 CNTRLR [Node 038] [Configuration] 89: metadata updated 12:28:48.841 CNTRLR [Node 038] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 12:28:48.841 CNTRLR » [Node 038] querying parameter #1 value... 12:28:48.848 SERIAL » 0x010a0013260370050125a133 (12 bytes) 12:28:48.848 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 161 └─[ConfigurationCCGet] parameter #: 1 12:28:48.887 SERIAL « [ACK] (0x06) 12:28:48.889 SERIAL « 0x0104011301e8 (6 bytes) 12:28:48.889 SERIAL » [ACK] (0x06) 12:28:48.898 DRIVER « [RES] [SendData] was sent: true 12:28:48.919 SERIAL « 0x01070013a10000074d (9 bytes) 12:28:48.920 SERIAL » [ACK] (0x06) 12:28:48.921 DRIVER « [REQ] [SendData] callback id: 161 transmit status: OK 12:28:48.975 SERIAL « 0x010c0004002606700601020000a2 (14 bytes) 12:28:48.982 CNTRLR [Node 038] [+] [Configuration] 1: 0 12:28:48.984 SERIAL » [ACK] (0x06) 12:28:48.988 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 2 value: 0 12:28:48.993 CNTRLR « [Node 038] parameter #1 has value: 0 12:28:48.994 CNTRLR » [Node 038] querying parameter #2 value... 12:28:49.003 SERIAL » 0x010a0013260370050225a233 (12 bytes) 12:28:49.003 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 162 └─[ConfigurationCCGet] parameter #: 2 12:28:49.006 SERIAL « [ACK] (0x06) 12:28:49.016 SERIAL « 0x0104011301e8 (6 bytes) 12:28:49.018 SERIAL » [ACK] (0x06) 12:28:49.020 DRIVER « [RES] [SendData] was sent: true 12:28:49.111 SERIAL « 0x01070013a200000b42 (9 bytes) 12:28:49.112 SERIAL » [ACK] (0x06) 12:28:49.113 DRIVER « [REQ] [SendData] callback id: 162 transmit status: OK 12:28:49.160 SERIAL « 0x010b00040026057006020103a5 (13 bytes) 12:28:49.163 CNTRLR [Node 038] [+] [Configuration] 2: 3 12:28:49.164 SERIAL » [ACK] (0x06) 12:28:49.168 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 3 12:28:49.170 CNTRLR « [Node 038] parameter #2 has value: 3 12:28:49.171 CNTRLR » [Node 038] querying parameter #5 value... 12:28:49.176 SERIAL » 0x010a0013260370050525a335 (12 bytes) 12:28:49.177 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 163 └─[ConfigurationCCGet] parameter #: 5 12:28:49.179 SERIAL « [ACK] (0x06) 12:28:49.185 SERIAL « 0x0104011301e8 (6 bytes) 12:28:49.186 SERIAL » [ACK] (0x06) 12:28:49.188 DRIVER « [RES] [SendData] was sent: true 12:28:49.300 SERIAL « 0x01070013a300000c44 (9 bytes) 12:28:49.300 SERIAL » [ACK] (0x06) 12:28:49.301 DRIVER « [REQ] [SendData] callback id: 163 transmit status: OK 12:28:49.350 SERIAL « 0x010b000400260570060501ff5e (13 bytes) 12:28:49.353 CNTRLR [Node 038] [+] [Configuration] 5: 255 12:28:49.354 SERIAL » [ACK] (0x06) 12:28:49.355 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 5 value size: 1 value: 255 12:28:49.357 CNTRLR « [Node 038] parameter #5 has value: 255 12:28:49.357 CNTRLR » [Node 038] querying parameter #7 value... 12:28:49.361 SERIAL » 0x010a0013260370050725a430 (12 bytes) 12:28:49.362 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 164 └─[ConfigurationCCGet] parameter #: 7 12:28:49.366 SERIAL « [ACK] (0x06) 12:28:49.370 SERIAL « 0x0104011301e8 (6 bytes) 12:28:49.371 SERIAL » [ACK] (0x06) 12:28:49.372 DRIVER « [RES] [SendData] was sent: true 12:28:49.490 SERIAL « 0x01070013a400000d42 (9 bytes) 12:28:49.490 SERIAL » [ACK] (0x06) 12:28:49.491 DRIVER « [REQ] [SendData] callback id: 164 transmit status: OK 12:28:49.540 SERIAL « 0x010b000400260570060701ff5c (13 bytes) 12:28:49.543 CNTRLR [Node 038] [+] [Configuration] 7: 255 12:28:49.544 SERIAL » [ACK] (0x06) 12:28:49.545 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 7 value size: 1 value: 255 12:28:49.547 CNTRLR « [Node 038] parameter #7 has value: 255 12:28:49.547 CNTRLR » [Node 038] querying parameter #10 value... 12:28:49.553 SERIAL » 0x010a0013260370050a25a53c (12 bytes) 12:28:49.553 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 165 └─[ConfigurationCCGet] parameter #: 10 12:28:49.555 SERIAL « [ACK] (0x06) 12:28:49.562 SERIAL « 0x0104011301e8 (6 bytes) 12:28:49.562 SERIAL » [ACK] (0x06) 12:28:49.563 DRIVER « [RES] [SendData] was sent: true 12:28:49.680 SERIAL « 0x01070013a500000d43 (9 bytes) 12:28:49.680 SERIAL » [ACK] (0x06) 12:28:49.681 DRIVER « [REQ] [SendData] callback id: 165 transmit status: OK 12:28:49.847 SERIAL « 0x010c000400260670060a020000a9 (14 bytes) 12:28:49.851 CNTRLR [Node 038] [+] [Configuration] 10: 0 12:28:49.852 SERIAL » [ACK] (0x06) 12:28:49.854 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 2 value: 0 12:28:49.856 CNTRLR « [Node 038] parameter #10 has value: 0 12:28:49.856 CNTRLR » [Node 038] querying parameter #12 value... 12:28:49.878 SERIAL » 0x010a0013260370050c25a639 (12 bytes) 12:28:49.879 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 166 └─[ConfigurationCCGet] parameter #: 12 12:28:49.882 SERIAL « [ACK] (0x06) 12:28:49.888 SERIAL « 0x0104011301e8 (6 bytes) 12:28:49.888 SERIAL » [ACK] (0x06) 12:28:49.890 DRIVER « [RES] [SendData] was sent: true 12:28:49.981 SERIAL « 0x01070013a600000a47 (9 bytes) 12:28:49.981 SERIAL » [ACK] (0x06) 12:28:49.982 DRIVER « [REQ] [SendData] callback id: 166 transmit status: OK 12:28:50.078 SERIAL « 0x010b000400260570060c0114bc (13 bytes) 12:28:50.082 CNTRLR [Node 038] [+] [Configuration] 12: 20 12:28:50.082 SERIAL » [ACK] (0x06) 12:28:50.084 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 1 value: 20 12:28:50.087 CNTRLR « [Node 038] parameter #12 has value: 20 12:28:50.087 CNTRLR » [Node 038] querying parameter #13 value... 12:28:50.093 SERIAL » 0x010a0013260370050d25a739 (12 bytes) 12:28:50.094 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 167 └─[ConfigurationCCGet] parameter #: 13 12:28:50.096 SERIAL « [ACK] (0x06) 12:28:50.102 SERIAL « 0x0104011301e8 (6 bytes) 12:28:50.103 SERIAL » [ACK] (0x06) 12:28:50.104 DRIVER « [RES] [SendData] was sent: true 12:28:50.210 SERIAL « 0x01070013a700000c40 (9 bytes) 12:28:50.210 SERIAL » [ACK] (0x06) 12:28:50.211 DRIVER « [REQ] [SendData] callback id: 167 transmit status: OK 12:28:50.260 SERIAL « 0x010b000400260570060d0100a9 (13 bytes) 12:28:50.264 CNTRLR [Node 038] [+] [Configuration] 13: 0 12:28:50.265 SERIAL » [ACK] (0x06) 12:28:50.267 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 1 value: 0 12:28:50.269 CNTRLR « [Node 038] parameter #13 has value: 0 12:28:50.270 CNTRLR » [Node 038] querying parameter #73 value... 12:28:50.277 SERIAL » 0x010a0013260370054925a872 (12 bytes) 12:28:50.277 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 168 └─[ConfigurationCCGet] parameter #: 73 12:28:50.283 SERIAL « [ACK] (0x06) 12:28:50.288 SERIAL « 0x0104011301e8 (6 bytes) 12:28:50.289 SERIAL » [ACK] (0x06) 12:28:50.290 DRIVER « [RES] [SendData] was sent: true 12:28:50.400 SERIAL « 0x01070013a800000c4f (9 bytes) 12:28:50.400 SERIAL » [ACK] (0x06) 12:28:50.401 DRIVER « [REQ] [SendData] callback id: 168 transmit status: OK 12:28:50.451 SERIAL « 0x010c0004002606700649020000ea (14 bytes) 12:28:50.456 CNTRLR [Node 038] [+] [Configuration] 73: 0 12:28:50.457 SERIAL » [ACK] (0x06) 12:28:50.460 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 73 value size: 2 value: 0 12:28:50.464 CNTRLR « [Node 038] parameter #73 has value: 0 12:28:50.464 CNTRLR » [Node 038] querying parameter #80 value... 12:28:50.470 SERIAL » 0x010a0013260370055025a96a (12 bytes) 12:28:50.470 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 169 └─[ConfigurationCCGet] parameter #: 80 12:28:50.472 SERIAL « [ACK] (0x06) 12:28:50.488 SERIAL « 0x0104011301e8 (6 bytes) 12:28:50.489 SERIAL » [ACK] (0x06) 12:28:50.490 DRIVER « [RES] [SendData] was sent: true 12:28:50.589 SERIAL « 0x01070013a900000c4e (9 bytes) 12:28:50.590 SERIAL » [ACK] (0x06) 12:28:50.591 DRIVER « [REQ] [SendData] callback id: 169 transmit status: OK 12:28:50.640 SERIAL « 0x010b00040026057006500101f5 (13 bytes) 12:28:50.645 CNTRLR [Node 038] [+] [Configuration] 80: 1 12:28:50.646 SERIAL » [ACK] (0x06) 12:28:50.648 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 80 value size: 1 value: 1 12:28:50.652 CNTRLR « [Node 038] parameter #80 has value: 1 12:28:50.653 CNTRLR » [Node 038] querying parameter #81 value... 12:28:50.661 SERIAL » 0x010a0013260370055125aa68 (12 bytes) 12:28:50.662 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 170 └─[ConfigurationCCGet] parameter #: 81 12:28:50.666 SERIAL « [ACK] (0x06) 12:28:50.671 SERIAL « 0x0104011301e8 (6 bytes) 12:28:50.672 SERIAL » [ACK] (0x06) 12:28:50.673 DRIVER « [RES] [SendData] was sent: true 12:28:50.784 SERIAL « 0x01070013aa00000c4d (9 bytes) 12:28:50.785 SERIAL » [ACK] (0x06) 12:28:50.786 DRIVER « [REQ] [SendData] callback id: 170 transmit status: OK 12:28:50.830 SERIAL « 0x010b00040026057006510136c3 (13 bytes) 12:28:50.834 CNTRLR [Node 038] [+] [Configuration] 81: 54 12:28:50.834 SERIAL » [ACK] (0x06) 12:28:50.836 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 81 value size: 1 value: 54 12:28:50.840 CNTRLR « [Node 038] parameter #81 has value: 54 12:28:50.841 CNTRLR » [Node 038] querying parameter #82 value... 12:28:50.845 SERIAL » 0x010a0013260370055225ab6a (12 bytes) 12:28:50.846 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 171 └─[ConfigurationCCGet] parameter #: 82 12:28:50.848 SERIAL « [ACK] (0x06) 12:28:50.855 SERIAL « 0x0104011301e8 (6 bytes) 12:28:50.856 SERIAL » [ACK] (0x06) 12:28:50.857 DRIVER « [RES] [SendData] was sent: true 12:28:51.074 SERIAL « 0x01070013ab00001656 (9 bytes) 12:28:51.080 SERIAL » [ACK] (0x06) 12:28:51.081 DRIVER « [REQ] [SendData] callback id: 171 transmit status: OK 12:28:51.138 SERIAL « 0x010b00040026057006520102f4 (13 bytes) 12:28:51.141 CNTRLR [Node 038] [+] [Configuration] 82: 2 12:28:51.146 SERIAL » [ACK] (0x06) 12:28:51.148 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 82 value size: 1 value: 2 12:28:51.150 CNTRLR « [Node 038] parameter #82 has value: 2 12:28:51.150 CNTRLR » [Node 038] querying parameter #83 value... 12:28:51.162 SERIAL » 0x010a0013260370055325ac6c (12 bytes) 12:28:51.163 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 172 └─[ConfigurationCCGet] parameter #: 83 12:28:51.166 SERIAL « [ACK] (0x06) 12:28:51.171 SERIAL « 0x0104011301e8 (6 bytes) 12:28:51.172 SERIAL » [ACK] (0x06) 12:28:51.173 DRIVER « [RES] [SendData] was sent: true 12:28:51.270 SERIAL « 0x01070013ac00000b4c (9 bytes) 12:28:51.271 SERIAL » [ACK] (0x06) 12:28:51.272 DRIVER « [REQ] [SendData] callback id: 172 transmit status: OK 12:28:51.320 SERIAL « 0x010b00040026057006530102f5 (13 bytes) 12:28:51.323 CNTRLR [Node 038] [+] [Configuration] 83: 2 12:28:51.324 SERIAL » [ACK] (0x06) 12:28:51.326 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 83 value size: 1 value: 2 12:28:51.327 CNTRLR « [Node 038] parameter #83 has value: 2 12:28:51.327 CNTRLR » [Node 038] querying parameter #84 value... 12:28:51.332 SERIAL » 0x010a0013260370055425ad6a (12 bytes) 12:28:51.332 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 173 └─[ConfigurationCCGet] parameter #: 84 12:28:51.335 SERIAL « [ACK] (0x06) 12:28:51.341 SERIAL « 0x0104011301e8 (6 bytes) 12:28:51.341 SERIAL » [ACK] (0x06) 12:28:51.342 DRIVER « [RES] [SendData] was sent: true 12:28:51.460 SERIAL « 0x01070013ad00000d4b (9 bytes) 12:28:51.461 SERIAL » [ACK] (0x06) 12:28:51.463 DRIVER « [REQ] [SendData] callback id: 173 transmit status: OK 12:28:51.510 SERIAL « 0x010b00040026057006540132c2 (13 bytes) 12:28:51.515 CNTRLR [Node 038] [+] [Configuration] 84: 50 12:28:51.516 SERIAL » [ACK] (0x06) 12:28:51.518 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 84 value size: 1 value: 50 12:28:51.521 CNTRLR « [Node 038] parameter #84 has value: 50 12:28:51.521 CNTRLR » [Node 038] querying parameter #85 value... 12:28:51.527 SERIAL » 0x010a0013260370055525ae68 (12 bytes) 12:28:51.528 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 174 └─[ConfigurationCCGet] parameter #: 85 12:28:51.531 SERIAL « [ACK] (0x06) 12:28:51.536 SERIAL « 0x0104011301e8 (6 bytes) 12:28:51.537 SERIAL » [ACK] (0x06) 12:28:51.538 DRIVER « [RES] [SendData] was sent: true 12:28:51.650 SERIAL « 0x01070013ae00000c49 (9 bytes) 12:28:51.651 SERIAL » [ACK] (0x06) 12:28:51.653 DRIVER « [REQ] [SendData] callback id: 174 transmit status: OK 12:28:51.700 SERIAL « 0x010b00040026057006550105f4 (13 bytes) 12:28:51.707 CNTRLR [Node 038] [+] [Configuration] 85: 5 12:28:51.708 SERIAL » [ACK] (0x06) 12:28:51.710 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 85 value size: 1 value: 5 12:28:51.713 CNTRLR « [Node 038] parameter #85 has value: 5 12:28:51.713 CNTRLR » [Node 038] querying parameter #86 value... 12:28:51.720 SERIAL » 0x010a0013260370055625af6a (12 bytes) 12:28:51.721 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 175 └─[ConfigurationCCGet] parameter #: 86 12:28:51.725 SERIAL « [ACK] (0x06) 12:28:51.730 SERIAL « 0x0104011301e8 (6 bytes) 12:28:51.731 SERIAL » [ACK] (0x06) 12:28:51.732 DRIVER « [RES] [SendData] was sent: true 12:28:51.889 SERIAL « 0x01070013af00001155 (9 bytes) 12:28:51.891 SERIAL » [ACK] (0x06) 12:28:51.892 DRIVER « [REQ] [SendData] callback id: 175 transmit status: OK 12:28:51.938 SERIAL « 0x010c00040026067006560201689c (14 bytes) 12:28:51.944 CNTRLR [Node 038] [+] [Configuration] 86: 360 12:28:51.945 SERIAL » [ACK] (0x06) 12:28:51.947 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 86 value size: 2 value: 360 12:28:51.950 CNTRLR « [Node 038] parameter #86 has value: 360 12:28:51.950 CNTRLR » [Node 038] querying parameter #87 value... 12:28:51.958 SERIAL » 0x010a0013260370055725b074 (12 bytes) 12:28:51.958 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 176 └─[ConfigurationCCGet] parameter #: 87 12:28:51.964 SERIAL « [ACK] (0x06) 12:28:51.974 SERIAL « 0x0104011301e8 (6 bytes) 12:28:51.975 SERIAL » [ACK] (0x06) 12:28:51.977 DRIVER « [RES] [SendData] was sent: true 12:28:52.080 SERIAL « 0x01070013b000000c57 (9 bytes) 12:28:52.081 SERIAL » [ACK] (0x06) 12:28:52.082 DRIVER « [REQ] [SendData] callback id: 176 transmit status: OK 12:28:52.131 SERIAL « 0x010c00040026067006570201689d (14 bytes) 12:28:52.138 CNTRLR [Node 038] [+] [Configuration] 87: 360 12:28:52.139 SERIAL » [ACK] (0x06) 12:28:52.142 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 87 value size: 2 value: 360 12:28:52.145 CNTRLR « [Node 038] parameter #87 has value: 360 12:28:52.145 CNTRLR » [Node 038] querying parameter #88 value... 12:28:52.160 SERIAL » 0x010a0013260370055825b17a (12 bytes) 12:28:52.161 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 177 └─[ConfigurationCCGet] parameter #: 88 12:28:52.166 SERIAL « [ACK] (0x06) 12:28:52.172 SERIAL « 0x0104011301e8 (6 bytes) 12:28:52.173 SERIAL » [ACK] (0x06) 12:28:52.176 DRIVER « [RES] [SendData] was sent: true 12:28:52.260 SERIAL « 0x01070013b100000a50 (9 bytes) 12:28:52.260 SERIAL » [ACK] (0x06) 12:28:52.261 DRIVER « [REQ] [SendData] callback id: 177 transmit status: OK 12:28:52.310 SERIAL « 0x010b00040026057006580100fc (13 bytes) 12:28:52.314 CNTRLR [Node 038] [+] [Configuration] 88: 0 12:28:52.314 SERIAL » [ACK] (0x06) 12:28:52.316 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 88 value size: 1 value: 0 12:28:52.318 CNTRLR « [Node 038] parameter #88 has value: 0 12:28:52.319 CNTRLR » [Node 038] querying parameter #89 value... 12:28:52.324 SERIAL » 0x010a0013260370055925b278 (12 bytes) 12:28:52.324 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 178 └─[ConfigurationCCGet] parameter #: 89 12:28:52.327 SERIAL « [ACK] (0x06) 12:28:52.334 SERIAL « 0x0104011301e8 (6 bytes) 12:28:52.335 SERIAL » [ACK] (0x06) 12:28:52.338 DRIVER « [RES] [SendData] was sent: true 12:28:52.450 SERIAL « 0x01070013b200000c55 (9 bytes) 12:28:52.450 SERIAL » [ACK] (0x06) 12:28:52.451 DRIVER « [REQ] [SendData] callback id: 178 transmit status: OK 12:28:52.500 SERIAL « 0x010b00040026057006590101fc (13 bytes) 12:28:52.504 CNTRLR [Node 038] [+] [Configuration] 89: 1 12:28:52.505 SERIAL » [ACK] (0x06) 12:28:52.506 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 89 value size: 1 value: 1 12:28:52.507 CNTRLR « [Node 038] parameter #89 has value: 1 12:28:52.508 CNTRLR [Node 038] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 12:28:52.521 CNTRLR [Node 038] MultiChannelAssociationCC: doing a partial interview... 12:28:52.522 CNTRLR » [Node 038] querying multi channel association group #1... 12:28:52.527 SERIAL » 0x010a001326038e020125b3d8 (12 bytes) 12:28:52.528 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 179 └─[MultiChannelAssociationCCGet] group id: 1 12:28:52.531 SERIAL « [ACK] (0x06) 12:28:52.536 SERIAL « 0x0104011301e8 (6 bytes) 12:28:52.537 SERIAL » [ACK] (0x06) 12:28:52.538 DRIVER « [RES] [SendData] was sent: true 12:28:52.640 SERIAL « 0x01070013b300000b53 (9 bytes) 12:28:52.641 SERIAL » [ACK] (0x06) 12:28:52.642 DRIVER « [REQ] [SendData] callback id: 179 transmit status: OK 12:28:52.691 SERIAL « 0x010b00040026058e030105005a (13 bytes) 12:28:52.692 SERIAL » [ACK] (0x06) 12:28:52.693 CNTRLR [Node 038] [~] [Multi Channel Association] maxNodes[1]: 5 => 5 12:28:52.695 CNTRLR [Node 038] [~] [Multi Channel Association] nodeIds[1]: => 12:28:52.696 CNTRLR [Node 038] [~] [Multi Channel Association] endpoints[1]: => 12:28:52.697 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 5 node ids: endpoints: 12:28:52.699 CNTRLR « [Node 038] received information for multi channel association group #1: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 12:28:52.699 CNTRLR » [Node 038] querying multi channel association group #2... 12:28:52.705 SERIAL » 0x010a001326038e020225b4dc (12 bytes) 12:28:52.705 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 180 └─[MultiChannelAssociationCCGet] group id: 2 12:28:52.709 SERIAL « [ACK] (0x06) 12:28:52.715 SERIAL « 0x0104011301e8 (6 bytes) 12:28:52.716 SERIAL » [ACK] (0x06) 12:28:52.721 DRIVER « [RES] [SendData] was sent: true 12:28:52.830 SERIAL « 0x01070013b400000c53 (9 bytes) 12:28:52.831 SERIAL » [ACK] (0x06) 12:28:52.831 DRIVER « [REQ] [SendData] callback id: 180 transmit status: OK 12:28:52.880 SERIAL « 0x010b00040026058e0302050059 (13 bytes) 12:28:52.881 SERIAL » [ACK] (0x06) 12:28:52.882 CNTRLR [Node 038] [~] [Multi Channel Association] maxNodes[2]: 5 => 5 12:28:52.884 CNTRLR [Node 038] [~] [Multi Channel Association] nodeIds[2]: => 12:28:52.885 CNTRLR [Node 038] [~] [Multi Channel Association] endpoints[2]: => 12:28:52.886 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 12:28:52.887 CNTRLR « [Node 038] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 12:28:52.887 CNTRLR » [Node 038] querying additional non-multi-channel association groups... 12:28:52.888 CNTRLR » [Node 038] querying association group #3... 12:28:52.892 SERIAL » 0x010a0013260385020325b5d7 (12 bytes) 12:28:52.892 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 181 └─[AssociationCCGet] group id: 3 12:28:52.895 SERIAL « [ACK] (0x06) 12:28:52.906 SERIAL « 0x0104011301e8 (6 bytes) 12:28:52.907 SERIAL » [ACK] (0x06) 12:28:52.910 DRIVER « [RES] [SendData] was sent: true 12:28:53.020 SERIAL « 0x01070013b500000d53 (9 bytes) 12:28:53.021 SERIAL » [ACK] (0x06) 12:28:53.022 DRIVER « [REQ] [SendData] callback id: 181 transmit status: OK 12:28:53.071 SERIAL « 0x010c000400260685030301000152 (14 bytes) 12:28:53.074 SERIAL » [ACK] (0x06) 12:28:53.077 CNTRLR [Node 038] [~] [Association] maxNodes[3]: 1 => 1 [internal] 12:28:53.078 CNTRLR [Node 038] [~] [Association] nodeIds[3]: 1 => 1 [internal] 12:28:53.079 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 3 max # of nodes: 1 node IDs: 1 reports to follow: 0 12:28:53.084 CNTRLR « [Node 038] received information for association group #3: maximum # of nodes: 1 currently assigned nodes: 1 12:28:53.085 CNTRLR [Node 038] [~] [Association] hasLifeline: true => true [internal] 12:28:53.086 CNTRLR [Node 038] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 12:28:53.135 CNTRLR [Node 038] Interview stage completed: CommandClasses 12:28:53.135 CNTRLR [Node 038] Interview stage completed: OverwriteConfig 12:28:53.135 CNTRLR » [Node 038] requesting node neighbors... 12:28:53.151 SERIAL » 0x01070080260000005e (9 bytes) 12:28:53.152 DRIVER » [Node 038] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 12:28:53.155 SERIAL « [ACK] (0x06) 12:28:53.157 SERIAL « 0x01200180810040000000000000000000000000000000000000000000000000000 (34 bytes) 09f 12:28:53.158 SERIAL » [ACK] (0x06) 12:28:53.159 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 8, 23 12:28:53.162 CNTRLR « [Node 038] node neighbors received: 1, 8, 23 12:28:53.162 CNTRLR [Node 038] Interview stage completed: Neighbors 12:28:53.162 CNTRLR [Node 038] Interview completed 12:28:54.163 CNTRLR » [Node 038] Sending node back to sleep... 12:28:54.172 SERIAL » 0x010900132602840825b6de (11 bytes) 12:28:54.173 DRIVER » [Node 038] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 182 └─[WakeUpCCNoMoreInformation] 12:28:54.175 SERIAL « [ACK] (0x06) 12:28:54.181 SERIAL « 0x0104011301e8 (6 bytes) 12:28:54.182 SERIAL » [ACK] (0x06) 12:28:54.184 DRIVER « [RES] [SendData] was sent: true 12:28:54.243 SERIAL « 0x01070013b60000075a (9 bytes) 12:28:54.244 SERIAL » [ACK] (0x06) 12:28:54.246 DRIVER « [REQ] [SendData] callback id: 182 transmit status: OK 12:28:54.251 CNTRLR [Node 038] The node is now asleep. 12:28:56.842 SERIAL « 0x010d00040026079c022600ff000090 (15 bytes) 12:28:56.843 CNTRLR [Node 038] [~] [Alarm Sensor] state[0]: false => true [Endpoint 0] 12:28:56.844 CNTRLR [Node 038] [~] [Alarm Sensor] severity[0]: undefined => undefined [Endpoint 0] 12:28:56.845 CNTRLR [Node 038] [~] [Alarm Sensor] duration[0]: undefined => undefined [Endpoint 0] 12:28:56.845 SERIAL » [ACK] (0x06) 12:28:56.848 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: true 12:29:09.677 SERIAL « 0x010d00041026079c0226000000007f (15 bytes) 12:29:09.680 CNTRLR [Node 038] [~] [Alarm Sensor] state[0]: true => false [Endpoint 0] 12:29:09.682 CNTRLR [Node 038] [~] [Alarm Sensor] severity[0]: undefined => undefined [Endpoint 0] 12:29:09.683 CNTRLR [Node 038] [~] [Alarm Sensor] duration[0]: undefined => undefined [Endpoint 0] 12:29:09.684 SERIAL » [ACK] (0x06) 12:29:09.688 DRIVER « [Node 038] [REQ] [ApplicationCommand] └─[AlarmSensorCCReport] sensor type: General Purpose alarm state: false 12:30:35.450 SERIAL « 0x01080004002102840753 (10 bytes) 12:30:35.451 SERIAL » [ACK] (0x06) 12:30:35.453 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[WakeUpCCWakeUpNotification] 12:30:35.455 CNTRLR « [Node 033] received wakeup notification 12:30:35.457 CNTRLR [Node 033] The node is now awake. 12:30:35.468 SERIAL » 0x010900132102800225b7d6 (11 bytes) 12:30:35.469 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 183 └─[BatteryCCGet] 12:30:35.472 SERIAL « [ACK] (0x06) 12:30:35.477 SERIAL « 0x0104011301e8 (6 bytes) 12:30:35.478 SERIAL » [ACK] (0x06) 12:30:35.480 DRIVER « [RES] [SendData] was sent: true 12:30:35.559 SERIAL « 0x01070013b700000955 (9 bytes) 12:30:35.560 SERIAL » [ACK] (0x06) 12:30:35.561 DRIVER « [REQ] [SendData] callback id: 183 transmit status: OK 12:30:35.633 SERIAL « 0x0109000400210380036437 (11 bytes) 12:30:35.642 CNTRLR [Node 033] [~] [Battery] level: 100 => 100 [Endpoint 0] 12:30:35.643 CNTRLR [Node 033] [~] [Battery] isLow: false => false [Endpoint 0] 12:30:35.644 SERIAL » [ACK] (0x06) 12:30:35.646 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[BatteryCCReport] level: 100 is low: false 12:30:35.651 CNTRLR « [Node 033] received response for battery information: level: 100 12:30:35.652 CNTRLR [Node 033] [~] [Battery] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:30:35.677 CNTRLR [Node 033] WakeUpCC: doing a partial interview... 12:30:35.678 CNTRLR » [Node 033] retrieving wakeup interval from the device... 12:30:35.687 SERIAL » 0x010900132102840525b8da (11 bytes) 12:30:35.688 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 184 └─[WakeUpCCIntervalGet] 12:30:35.692 SERIAL « [ACK] (0x06) 12:30:35.697 SERIAL « 0x0104011301e8 (6 bytes) 12:30:35.697 SERIAL » [ACK] (0x06) 12:30:35.698 DRIVER « [RES] [SendData] was sent: true 12:30:35.740 SERIAL « 0x01070013b800000556 (9 bytes) 12:30:35.741 SERIAL » [ACK] (0x06) 12:30:35.742 DRIVER « [REQ] [SendData] callback id: 184 transmit status: OK 12:30:35.813 SERIAL « 0x010c000400210684060054600167 (14 bytes) 12:30:35.815 CNTRLR [Node 033] [~] [Wake Up] wakeUpInterval: 21600 => 21600 [Endpoint 0] 12:30:35.816 CNTRLR [Node 033] [~] [Wake Up] controllerNodeId: 1 => 1 [Endpoint 0] 12:30:35.817 SERIAL » [ACK] (0x06) 12:30:35.819 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[WakeUpCCIntervalReport] wake-up interval: 21600 seconds controller node id: 1 12:30:35.822 CNTRLR « [Node 033] received wakeup configuration: wakeup interval: 21600 seconds controller node: 1 12:30:35.823 CNTRLR [Node 033] [~] [Wake Up] interviewComplete: true => tr [Endpoint 0] [internal] ue 12:30:35.824 CNTRLR [Node 033] BasicCC: doing a partial interview... 12:30:35.824 CNTRLR » [Node 033] querying Basic CC state... 12:30:35.833 SERIAL » 0x010900132102200225b978 (11 bytes) 12:30:35.834 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 185 └─[BasicCCGet] 12:30:35.837 SERIAL « [ACK] (0x06) 12:30:35.848 SERIAL « 0x0104011301e8 (6 bytes) 12:30:35.848 SERIAL » [ACK] (0x06) 12:30:35.851 DRIVER « [RES] [SendData] was sent: true 12:30:35.920 SERIAL « 0x01070013b90000095b (9 bytes) 12:30:35.921 SERIAL » [ACK] (0x06) 12:30:35.922 DRIVER « [REQ] [SendData] callback id: 185 transmit status: OK 12:30:35.992 SERIAL « 0x01090004002103200300f3 (11 bytes) 12:30:35.994 SERIAL » [ACK] (0x06) 12:30:35.995 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[BasicCCReport] current value: 0 12:30:35.997 CNTRLR « [Node 033] received Basic CC state: current value: 0 12:30:35.998 CNTRLR [Node 033] [~] [Basic] interviewComplete: true => true [Endpoint 0] [internal] 12:30:35.999 CNTRLR [Node 033] BinarySensorCC: doing a partial interview... 12:30:36.000 CNTRLR » [Node 033] querying current value... 12:30:36.007 SERIAL » 0x010900132102300225ba6b (11 bytes) 12:30:36.008 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 186 └─[BinarySensorCCGet] type: Any 12:30:36.010 SERIAL « [ACK] (0x06) 12:30:36.016 SERIAL « 0x0104011301e8 (6 bytes) 12:30:36.016 SERIAL » [ACK] (0x06) 12:30:36.017 DRIVER « [RES] [SendData] was sent: true 12:30:36.099 SERIAL « 0x01070013ba00000958 (9 bytes) 12:30:36.100 SERIAL » [ACK] (0x06) 12:30:36.101 DRIVER « [REQ] [SendData] callback id: 186 transmit status: OK 12:30:36.172 SERIAL « 0x01090004002103300300e3 (11 bytes) 12:30:36.174 CNTRLR [Node 033] [Binary Sensor] Any: metadata updated [Endpoint 0] 12:30:36.175 CNTRLR [Node 033] [~] [Binary Sensor] Any: false => false [Endpoint 0] 12:30:36.176 SERIAL » [ACK] (0x06) 12:30:36.178 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[BinarySensorCCReport] type: Any value: false 12:30:36.180 CNTRLR « [Node 033] received current value: false 12:30:36.181 CNTRLR [Node 033] [~] [Binary Sensor] interviewComplete: true [Endpoint 0] [internal] => true 12:30:36.182 CNTRLR [Node 033] ConfigurationCC: Loading configuration parameters from device confi g 12:30:36.187 CNTRLR [Node 033] [~] [Configuration] isParamInformationFromConfig: true = [internal] > false 12:30:36.188 CNTRLR [Node 033] [Configuration] 1: metadata updated 12:30:36.190 CNTRLR [Node 033] [Configuration] 2: metadata updated 12:30:36.191 CNTRLR [Node 033] [Configuration] 3: metadata updated 12:30:36.192 CNTRLR [Node 033] [Configuration] 4: metadata updated 12:30:36.194 CNTRLR [Node 033] [Configuration] 10: metadata updated 12:30:36.195 CNTRLR [Node 033] [Configuration] 11: metadata updated 12:30:36.197 CNTRLR [Node 033] [Configuration] 12: metadata updated 12:30:36.198 CNTRLR [Node 033] [Configuration] 13: metadata updated 12:30:36.199 CNTRLR [Node 033] [Configuration] 14: metadata updated 12:30:36.201 CNTRLR [Node 033] [Configuration] 15: metadata updated 12:30:36.202 CNTRLR [Node 033] [Configuration] 20: metadata updated 12:30:36.205 CNTRLR [Node 033] [Configuration] 30: metadata updated 12:30:36.208 CNTRLR [Node 033] [Configuration] 31: metadata updated 12:30:36.210 CNTRLR [Node 033] [Configuration] 50: metadata updated 12:30:36.211 CNTRLR [Node 033] [Configuration] 51: metadata updated 12:30:36.213 CNTRLR [Node 033] [Configuration] 52: metadata updated 12:30:36.214 CNTRLR [Node 033] [Configuration] 53: metadata updated 12:30:36.215 CNTRLR [Node 033] [Configuration] 54: metadata updated 12:30:36.217 CNTRLR [Node 033] [Configuration] 55: metadata updated 12:30:36.218 CNTRLR [Node 033] [Configuration] 56: metadata updated 12:30:36.224 CNTRLR [Node 033] [Configuration] 70: metadata updated 12:30:36.226 CNTRLR [Node 033] [Configuration] 71: metadata updated 12:30:36.228 CNTRLR [Node 033] [Configuration] 72: metadata updated 12:30:36.229 CNTRLR [Node 033] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 12:30:36.230 CNTRLR » [Node 033] querying parameter #1 value... 12:30:36.237 SERIAL » 0x010a0013210370050125bb2e (12 bytes) 12:30:36.237 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 187 └─[ConfigurationCCGet] parameter #: 1 12:30:36.246 SERIAL « [ACK] (0x06) 12:30:36.248 SERIAL « 0x0104011301e8 (6 bytes) 12:30:36.248 SERIAL » [ACK] (0x06) 12:30:36.249 DRIVER « [RES] [SendData] was sent: true 12:30:36.290 SERIAL « 0x01070013bb00000555 (9 bytes) 12:30:36.291 SERIAL » [ACK] (0x06) 12:30:36.293 DRIVER « [REQ] [SendData] callback id: 187 transmit status: OK 12:30:36.363 SERIAL « 0x010b00040021057006010100a2 (13 bytes) 12:30:36.367 CNTRLR [Node 033] [~] [Configuration] 1: 0 => 0 12:30:36.368 SERIAL » [ACK] (0x06) 12:30:36.371 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 1 value size: 1 value: 0 12:30:36.375 CNTRLR « [Node 033] parameter #1 has value: 0 12:30:36.376 CNTRLR » [Node 033] querying parameter #2 value... 12:30:36.382 SERIAL » 0x010a0013210370050225bc2a (12 bytes) 12:30:36.383 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 188 └─[ConfigurationCCGet] parameter #: 2 12:30:36.385 SERIAL « [ACK] (0x06) 12:30:36.392 SERIAL « 0x0104011301e8 (6 bytes) 12:30:36.392 SERIAL » [ACK] (0x06) 12:30:36.394 DRIVER « [RES] [SendData] was sent: true 12:30:36.469 SERIAL « 0x01070013bc0000095e (9 bytes) 12:30:36.470 SERIAL » [ACK] (0x06) 12:30:36.471 DRIVER « [REQ] [SendData] callback id: 188 transmit status: OK 12:30:36.543 SERIAL « 0x010b00040021057006020100a1 (13 bytes) 12:30:36.546 CNTRLR [Node 033] [~] [Configuration] 2: 0 => 0 12:30:36.547 SERIAL » [ACK] (0x06) 12:30:36.548 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 2 value size: 1 value: 0 12:30:36.550 CNTRLR « [Node 033] parameter #2 has value: 0 12:30:36.550 CNTRLR » [Node 033] querying parameter #3 value... 12:30:36.557 SERIAL » 0x010a0013210370050325bd2a (12 bytes) 12:30:36.558 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 189 └─[ConfigurationCCGet] parameter #: 3 12:30:36.561 SERIAL « [ACK] (0x06) 12:30:36.566 SERIAL « 0x0104011301e8 (6 bytes) 12:30:36.567 SERIAL » [ACK] (0x06) 12:30:36.568 DRIVER « [RES] [SendData] was sent: true 12:30:36.650 SERIAL « 0x01070013bd0000095f (9 bytes) 12:30:36.650 SERIAL » [ACK] (0x06) 12:30:36.651 DRIVER « [REQ] [SendData] callback id: 189 transmit status: OK 12:30:36.723 SERIAL « 0x010b00040021057006030106a6 (13 bytes) 12:30:36.726 CNTRLR [Node 033] [~] [Configuration] 3: 6 => 6 12:30:36.727 SERIAL » [ACK] (0x06) 12:30:36.729 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 3 value size: 1 value: 6 12:30:36.731 CNTRLR « [Node 033] parameter #3 has value: 6 12:30:36.731 CNTRLR » [Node 033] querying parameter #4 value... 12:30:36.736 SERIAL » 0x010a0013210370050425be2e (12 bytes) 12:30:36.737 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 190 └─[ConfigurationCCGet] parameter #: 4 12:30:36.740 SERIAL « [ACK] (0x06) 12:30:36.745 SERIAL « 0x0104011301e8 (6 bytes) 12:30:36.746 SERIAL » [ACK] (0x06) 12:30:36.747 DRIVER « [RES] [SendData] was sent: true 12:30:36.830 SERIAL « 0x01070013be0000095c (9 bytes) 12:30:36.830 SERIAL » [ACK] (0x06) 12:30:36.831 DRIVER « [REQ] [SendData] callback id: 190 transmit status: OK 12:30:36.903 SERIAL « 0x010b00040021057006040100a7 (13 bytes) 12:30:36.906 CNTRLR [Node 033] [~] [Configuration] 4: 0 => 0 12:30:36.907 SERIAL » [ACK] (0x06) 12:30:36.907 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 4 value size: 1 value: 0 12:30:36.909 CNTRLR « [Node 033] parameter #4 has value: 0 12:30:36.909 CNTRLR » [Node 033] querying parameter #10 value... 12:30:36.914 SERIAL » 0x010a0013210370050a25bf21 (12 bytes) 12:30:36.914 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 191 └─[ConfigurationCCGet] parameter #: 10 12:30:36.917 SERIAL « [ACK] (0x06) 12:30:36.922 SERIAL « 0x0104011301e8 (6 bytes) 12:30:36.923 SERIAL » [ACK] (0x06) 12:30:36.924 DRIVER « [RES] [SendData] was sent: true 12:30:37.010 SERIAL « 0x01070013bf00000a5e (9 bytes) 12:30:37.011 SERIAL » [ACK] (0x06) 12:30:37.012 DRIVER « [REQ] [SendData] callback id: 191 transmit status: OK 12:30:37.084 SERIAL « 0x010b000400210570060a0100a9 (13 bytes) 12:30:37.091 CNTRLR [Node 033] [~] [Configuration] 10: 0 => 0 12:30:37.092 SERIAL » [ACK] (0x06) 12:30:37.095 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 0 12:30:37.097 CNTRLR « [Node 033] parameter #10 has value: 0 12:30:37.098 CNTRLR » [Node 033] querying parameter #11 value... 12:30:37.104 SERIAL » 0x010a0013210370050b25c05f (12 bytes) 12:30:37.104 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 192 └─[ConfigurationCCGet] parameter #: 11 12:30:37.107 SERIAL « [ACK] (0x06) 12:30:37.114 SERIAL « 0x0104011301e8 (6 bytes) 12:30:37.114 SERIAL » [ACK] (0x06) 12:30:37.115 DRIVER « [RES] [SendData] was sent: true 12:30:37.190 SERIAL « 0x01070013c000000922 (9 bytes) 12:30:37.190 SERIAL » [ACK] (0x06) 12:30:37.191 DRIVER « [REQ] [SendData] callback id: 192 transmit status: OK 12:30:37.263 SERIAL « 0x010b000400210570060b0102aa (13 bytes) 12:30:37.269 CNTRLR [Node 033] [~] [Configuration] 11: 2 => 2 12:30:37.270 SERIAL » [ACK] (0x06) 12:30:37.272 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 11 value size: 1 value: 2 12:30:37.274 CNTRLR « [Node 033] parameter #11 has value: 2 12:30:37.275 CNTRLR » [Node 033] querying parameter #12 value... 12:30:37.288 SERIAL » 0x010a0013210370050c25c159 (12 bytes) 12:30:37.289 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 193 └─[ConfigurationCCGet] parameter #: 12 12:30:37.293 SERIAL « [ACK] (0x06) 12:30:37.300 SERIAL « 0x0104011301e8 (6 bytes) 12:30:37.300 SERIAL » [ACK] (0x06) 12:30:37.301 DRIVER « [RES] [SendData] was sent: true 12:30:37.370 SERIAL « 0x01070013c100000822 (9 bytes) 12:30:37.370 SERIAL » [ACK] (0x06) 12:30:37.371 DRIVER « [REQ] [SendData] callback id: 193 transmit status: OK 12:30:37.443 SERIAL « 0x010c000400210670060c0200ff57 (14 bytes) 12:30:37.449 CNTRLR [Node 033] [~] [Configuration] 12: 255 => 255 12:30:37.451 SERIAL » [ACK] (0x06) 12:30:37.452 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 255 12:30:37.455 CNTRLR « [Node 033] parameter #12 has value: 255 12:30:37.455 CNTRLR » [Node 033] querying parameter #13 value... 12:30:37.463 SERIAL » 0x010a0013210370050d25c25b (12 bytes) 12:30:37.464 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 194 └─[ConfigurationCCGet] parameter #: 13 12:30:37.468 SERIAL « [ACK] (0x06) 12:30:37.476 SERIAL « 0x0104011301e8 (6 bytes) 12:30:37.478 SERIAL » [ACK] (0x06) 12:30:37.480 DRIVER « [RES] [SendData] was sent: true 12:30:37.550 SERIAL « 0x01070013c200000920 (9 bytes) 12:30:37.550 SERIAL » [ACK] (0x06) 12:30:37.551 DRIVER « [REQ] [SendData] callback id: 194 transmit status: OK 12:30:37.623 SERIAL « 0x010c000400210670060d020000a9 (14 bytes) 12:30:37.627 CNTRLR [Node 033] [~] [Configuration] 13: 0 => 0 12:30:37.628 SERIAL » [ACK] (0x06) 12:30:37.629 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 2 value: 0 12:30:37.632 CNTRLR « [Node 033] parameter #13 has value: 0 12:30:37.632 CNTRLR » [Node 033] querying parameter #14 value... 12:30:37.638 SERIAL » 0x010a0013210370050e25c359 (12 bytes) 12:30:37.639 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 195 └─[ConfigurationCCGet] parameter #: 14 12:30:37.642 SERIAL « [ACK] (0x06) 12:30:37.650 SERIAL « 0x0104011301e8 (6 bytes) 12:30:37.651 SERIAL » [ACK] (0x06) 12:30:37.652 DRIVER « [RES] [SendData] was sent: true 12:30:37.730 SERIAL « 0x01070013c300000921 (9 bytes) 12:30:37.730 SERIAL » [ACK] (0x06) 12:30:37.731 DRIVER « [REQ] [SendData] callback id: 195 transmit status: OK 12:30:37.803 SERIAL « 0x010c000400210670060e020000aa (14 bytes) 12:30:37.806 CNTRLR [Node 033] [~] [Configuration] 14: 0 => 0 12:30:37.807 SERIAL » [ACK] (0x06) 12:30:37.808 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 14 value size: 2 value: 0 12:30:37.811 CNTRLR « [Node 033] parameter #14 has value: 0 12:30:37.812 CNTRLR » [Node 033] querying parameter #15 value... 12:30:37.816 SERIAL » 0x010a0013210370050f25c45f (12 bytes) 12:30:37.816 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 196 └─[ConfigurationCCGet] parameter #: 15 12:30:37.819 SERIAL « [ACK] (0x06) 12:30:37.825 SERIAL « 0x0104011301e8 (6 bytes) 12:30:37.826 SERIAL » [ACK] (0x06) 12:30:37.827 DRIVER « [RES] [SendData] was sent: true 12:30:37.910 SERIAL « 0x01070013c400000926 (9 bytes) 12:30:37.910 SERIAL » [ACK] (0x06) 12:30:37.911 DRIVER « [REQ] [SendData] callback id: 196 transmit status: OK 12:30:37.983 SERIAL « 0x010c000400210670060f020000ab (14 bytes) 12:30:37.986 CNTRLR [Node 033] [~] [Configuration] 15: 0 => 0 12:30:37.987 SERIAL » [ACK] (0x06) 12:30:37.988 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 15 value size: 2 value: 0 12:30:37.990 CNTRLR « [Node 033] parameter #15 has value: 0 12:30:37.990 CNTRLR » [Node 033] querying parameter #20 value... 12:30:37.996 SERIAL » 0x010a0013210370051425c545 (12 bytes) 12:30:37.996 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 197 └─[ConfigurationCCGet] parameter #: 20 12:30:37.999 SERIAL « [ACK] (0x06) 12:30:38.007 SERIAL « 0x0104011301e8 (6 bytes) 12:30:38.009 SERIAL » [ACK] (0x06) 12:30:38.010 DRIVER « [RES] [SendData] was sent: true 12:30:38.090 SERIAL « 0x01070013c500000927 (9 bytes) 12:30:38.090 SERIAL » [ACK] (0x06) 12:30:38.091 DRIVER « [REQ] [SendData] callback id: 197 transmit status: OK 12:30:38.164 SERIAL « 0x010b00040021057006140100b7 (13 bytes) 12:30:38.168 CNTRLR [Node 033] [~] [Configuration] 20: 0 => 0 12:30:38.170 SERIAL » [ACK] (0x06) 12:30:38.172 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 0 12:30:38.175 CNTRLR « [Node 033] parameter #20 has value: 0 12:30:38.175 CNTRLR » [Node 033] querying parameter #30 value... 12:30:38.179 SERIAL » 0x010a0013210370051e25c64c (12 bytes) 12:30:38.180 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 198 └─[ConfigurationCCGet] parameter #: 30 12:30:38.182 SERIAL « [ACK] (0x06) 12:30:38.190 SERIAL « 0x0104011301e8 (6 bytes) 12:30:38.191 SERIAL » [ACK] (0x06) 12:30:38.191 DRIVER « [RES] [SendData] was sent: true 12:30:38.270 SERIAL « 0x01070013c600000924 (9 bytes) 12:30:38.271 SERIAL » [ACK] (0x06) 12:30:38.272 DRIVER « [REQ] [SendData] callback id: 198 transmit status: OK 12:30:38.350 SERIAL « 0x010c000400210670061e020005bf (14 bytes) 12:30:38.356 CNTRLR [Node 033] [~] [Configuration] 30: 5 => 5 12:30:38.357 SERIAL » [ACK] (0x06) 12:30:38.361 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 2 value: 5 12:30:38.364 CNTRLR « [Node 033] parameter #30 has value: 5 12:30:38.364 CNTRLR » [Node 033] querying parameter #31 value... 12:30:38.373 SERIAL » 0x010a0013210370051f25c74c (12 bytes) 12:30:38.374 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 199 └─[ConfigurationCCGet] parameter #: 31 12:30:38.380 SERIAL « [ACK] (0x06) 12:30:38.386 SERIAL « 0x0104011301e8 (6 bytes) 12:30:38.387 SERIAL » [ACK] (0x06) 12:30:38.390 DRIVER « [RES] [SendData] was sent: true 12:30:38.450 SERIAL « 0x01070013c700000824 (9 bytes) 12:30:38.450 SERIAL » [ACK] (0x06) 12:30:38.451 DRIVER « [REQ] [SendData] callback id: 199 transmit status: OK 12:30:38.523 SERIAL « 0x010b000400210570061f0101bd (13 bytes) 12:30:38.526 CNTRLR [Node 033] [~] [Configuration] 31: 1 => 1 12:30:38.527 SERIAL » [ACK] (0x06) 12:30:38.527 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 1 value: 1 12:30:38.529 CNTRLR « [Node 033] parameter #31 has value: 1 12:30:38.530 CNTRLR » [Node 033] querying parameter #50 value... 12:30:38.534 SERIAL » 0x010a0013210370053225c86e (12 bytes) 12:30:38.534 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 200 └─[ConfigurationCCGet] parameter #: 50 12:30:38.537 SERIAL « [ACK] (0x06) 12:30:38.543 SERIAL « 0x0104011301e8 (6 bytes) 12:30:38.544 SERIAL » [ACK] (0x06) 12:30:38.545 DRIVER « [RES] [SendData] was sent: true 12:30:38.630 SERIAL « 0x01070013c800000a29 (9 bytes) 12:30:38.630 SERIAL » [ACK] (0x06) 12:30:38.631 DRIVER « [REQ] [SendData] callback id: 200 transmit status: OK 12:30:38.703 SERIAL « 0x010c000400210670063202012cbb (14 bytes) 12:30:38.706 CNTRLR [Node 033] [~] [Configuration] 50: 300 => 300 12:30:38.708 SERIAL » [ACK] (0x06) 12:30:38.709 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 2 value: 300 12:30:38.711 CNTRLR « [Node 033] parameter #50 has value: 300 12:30:38.711 CNTRLR » [Node 033] querying parameter #51 value... 12:30:38.721 SERIAL » 0x010a0013210370053325c96e (12 bytes) 12:30:38.722 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 201 └─[ConfigurationCCGet] parameter #: 51 12:30:38.731 SERIAL « [ACK] (0x06) 12:30:38.732 SERIAL « 0x0104011301e8 (6 bytes) 12:30:38.733 SERIAL » [ACK] (0x06) 12:30:38.735 DRIVER « [RES] [SendData] was sent: true 12:30:38.810 SERIAL « 0x01070013c90000092b (9 bytes) 12:30:38.811 SERIAL » [ACK] (0x06) 12:30:38.812 DRIVER « [REQ] [SendData] callback id: 201 transmit status: OK 12:30:38.883 SERIAL « 0x010c000400210670063302000a9d (14 bytes) 12:30:38.887 CNTRLR [Node 033] [~] [Configuration] 51: 10 => 10 12:30:38.887 SERIAL » [ACK] (0x06) 12:30:38.888 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 51 value size: 2 value: 10 12:30:38.890 CNTRLR « [Node 033] parameter #51 has value: 10 12:30:38.890 CNTRLR » [Node 033] querying parameter #52 value... 12:30:38.894 SERIAL » 0x010a0013210370053425ca6a (12 bytes) 12:30:38.895 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 202 └─[ConfigurationCCGet] parameter #: 52 12:30:38.897 SERIAL « [ACK] (0x06) 12:30:38.903 SERIAL « 0x0104011301e8 (6 bytes) 12:30:38.904 SERIAL » [ACK] (0x06) 12:30:38.905 DRIVER « [RES] [SendData] was sent: true 12:30:38.990 SERIAL « 0x01070013ca00000a2b (9 bytes) 12:30:38.991 SERIAL » [ACK] (0x06) 12:30:38.991 DRIVER « [REQ] [SendData] callback id: 202 transmit status: OK 12:30:39.063 SERIAL « 0x010c000400210670063402000090 (14 bytes) 12:30:39.066 CNTRLR [Node 033] [~] [Configuration] 52: 0 => 0 12:30:39.067 SERIAL » [ACK] (0x06) 12:30:39.069 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 52 value size: 2 value: 0 12:30:39.070 CNTRLR « [Node 033] parameter #52 has value: 0 12:30:39.071 CNTRLR » [Node 033] querying parameter #53 value... 12:30:39.080 SERIAL » 0x010a0013210370053525cb6a (12 bytes) 12:30:39.081 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 203 └─[ConfigurationCCGet] parameter #: 53 12:30:39.087 SERIAL « [ACK] (0x06) 12:30:39.090 SERIAL « 0x0104011301e8 (6 bytes) 12:30:39.091 SERIAL » [ACK] (0x06) 12:30:39.092 DRIVER « [RES] [SendData] was sent: true 12:30:39.170 SERIAL « 0x01070013cb00000929 (9 bytes) 12:30:39.170 SERIAL » [ACK] (0x06) 12:30:39.171 DRIVER « [REQ] [SendData] callback id: 203 transmit status: OK 12:30:39.244 SERIAL « 0x010c000400210670063502000091 (14 bytes) 12:30:39.248 CNTRLR [Node 033] [~] [Configuration] 53: 0 => 0 12:30:39.250 SERIAL » [ACK] (0x06) 12:30:39.251 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 53 value size: 2 value: 0 12:30:39.255 CNTRLR « [Node 033] parameter #53 has value: 0 12:30:39.255 CNTRLR » [Node 033] querying parameter #54 value... 12:30:39.265 SERIAL » 0x010a0013210370053625cc6e (12 bytes) 12:30:39.265 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 204 └─[ConfigurationCCGet] parameter #: 54 12:30:39.271 SERIAL « [ACK] (0x06) 12:30:39.276 SERIAL « 0x0104011301e8 (6 bytes) 12:30:39.277 SERIAL » [ACK] (0x06) 12:30:39.279 DRIVER « [RES] [SendData] was sent: true 12:30:39.350 SERIAL « 0x01070013cc0000082f (9 bytes) 12:30:39.350 SERIAL » [ACK] (0x06) 12:30:39.351 DRIVER « [REQ] [SendData] callback id: 204 transmit status: OK 12:30:39.423 SERIAL « 0x010b0004002105700636010095 (13 bytes) 12:30:39.431 CNTRLR [Node 033] [~] [Configuration] 54: 0 => 0 12:30:39.432 SERIAL » [ACK] (0x06) 12:30:39.434 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 54 value size: 1 value: 0 12:30:39.437 CNTRLR « [Node 033] parameter #54 has value: 0 12:30:39.438 CNTRLR » [Node 033] querying parameter #55 value... 12:30:39.446 SERIAL » 0x010a0013210370053725cd6e (12 bytes) 12:30:39.447 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 205 └─[ConfigurationCCGet] parameter #: 55 12:30:39.452 SERIAL « [ACK] (0x06) 12:30:39.457 SERIAL « 0x0104011301e8 (6 bytes) 12:30:39.458 SERIAL » [ACK] (0x06) 12:30:39.461 DRIVER « [RES] [SendData] was sent: true 12:30:39.530 SERIAL « 0x01070013cd0000082e (9 bytes) 12:30:39.531 SERIAL » [ACK] (0x06) 12:30:39.531 DRIVER « [REQ] [SendData] callback id: 205 transmit status: OK 12:30:39.603 SERIAL « 0x010c000400210670063702021c8d (14 bytes) 12:30:39.607 CNTRLR [Node 033] [~] [Configuration] 55: 540 => 540 12:30:39.608 SERIAL » [ACK] (0x06) 12:30:39.610 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 55 value size: 2 value: 540 12:30:39.615 CNTRLR « [Node 033] parameter #55 has value: 540 12:30:39.616 CNTRLR » [Node 033] querying parameter #56 value... 12:30:39.624 SERIAL » 0x010a0013210370053825ce62 (12 bytes) 12:30:39.625 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 206 └─[ConfigurationCCGet] parameter #: 56 12:30:39.629 SERIAL « [ACK] (0x06) 12:30:39.635 SERIAL « 0x0104011301e8 (6 bytes) 12:30:39.637 SERIAL » [ACK] (0x06) 12:30:39.639 DRIVER « [RES] [SendData] was sent: true 12:30:39.710 SERIAL « 0x01070013ce0000082d (9 bytes) 12:30:39.711 SERIAL » [ACK] (0x06) 12:30:39.712 DRIVER « [REQ] [SendData] callback id: 206 transmit status: OK 12:30:39.783 SERIAL « 0x010c0004002106700638020028b4 (14 bytes) 12:30:39.787 CNTRLR [Node 033] [~] [Configuration] 56: 40 => 40 12:30:39.788 SERIAL » [ACK] (0x06) 12:30:39.789 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 56 value size: 2 value: 40 12:30:39.792 CNTRLR « [Node 033] parameter #56 has value: 40 12:30:39.792 CNTRLR » [Node 033] querying parameter #70 value... 12:30:39.797 SERIAL » 0x010a0013210370054625cf1d (12 bytes) 12:30:39.798 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 207 └─[ConfigurationCCGet] parameter #: 70 12:30:39.801 SERIAL « [ACK] (0x06) 12:30:39.807 SERIAL « 0x0104011301e8 (6 bytes) 12:30:39.808 SERIAL » [ACK] (0x06) 12:30:39.809 DRIVER « [RES] [SendData] was sent: true 12:30:39.890 SERIAL « 0x01070013cf0000092d (9 bytes) 12:30:39.890 SERIAL » [ACK] (0x06) 12:30:39.891 DRIVER « [REQ] [SendData] callback id: 207 transmit status: OK 12:30:39.963 SERIAL « 0x010c0004002106700646020000e2 (14 bytes) 12:30:39.970 CNTRLR [Node 033] [~] [Configuration] 70: 0 => 0 12:30:39.971 SERIAL » [ACK] (0x06) 12:30:39.973 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 70 value size: 2 value: 0 12:30:39.976 CNTRLR « [Node 033] parameter #70 has value: 0 12:30:39.976 CNTRLR » [Node 033] querying parameter #71 value... 12:30:39.985 SERIAL » 0x010a0013210370054725d003 (12 bytes) 12:30:39.986 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 208 └─[ConfigurationCCGet] parameter #: 71 12:30:39.991 SERIAL « [ACK] (0x06) 12:30:40.001 SERIAL « 0x0104011301e8 (6 bytes) 12:30:40.001 SERIAL » [ACK] (0x06) 12:30:40.004 DRIVER « [RES] [SendData] was sent: true 12:30:40.070 SERIAL « 0x01070013d000000833 (9 bytes) 12:30:40.070 SERIAL » [ACK] (0x06) 12:30:40.071 DRIVER « [REQ] [SendData] callback id: 208 transmit status: OK 12:30:40.143 SERIAL « 0x010b00040021057006470100e4 (13 bytes) 12:30:40.149 CNTRLR [Node 033] [~] [Configuration] 71: 0 => 0 12:30:40.151 SERIAL » [ACK] (0x06) 12:30:40.152 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 71 value size: 1 value: 0 12:30:40.159 CNTRLR « [Node 033] parameter #71 has value: 0 12:30:40.160 CNTRLR » [Node 033] querying parameter #72 value... 12:30:40.169 SERIAL » 0x010a0013210370054825d10d (12 bytes) 12:30:40.170 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 209 └─[ConfigurationCCGet] parameter #: 72 12:30:40.177 SERIAL « [ACK] (0x06) 12:30:40.200 SERIAL « 0x0104011301e8 (6 bytes) 12:30:40.201 SERIAL » [ACK] (0x06) 12:30:40.202 DRIVER « [RES] [SendData] was sent: true 12:30:40.250 SERIAL « 0x01070013d100000832 (9 bytes) 12:30:40.250 SERIAL » [ACK] (0x06) 12:30:40.251 DRIVER « [REQ] [SendData] callback id: 209 transmit status: OK 12:30:40.323 SERIAL « 0x010b0004002105700648010fe4 (13 bytes) 12:30:40.326 CNTRLR [Node 033] [~] [Configuration] 72: 15 => 15 12:30:40.327 SERIAL » [ACK] (0x06) 12:30:40.328 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 72 value size: 1 value: 15 12:30:40.329 CNTRLR « [Node 033] parameter #72 has value: 15 12:30:40.330 CNTRLR [Node 033] [~] [Configuration] interviewComplete: true [Endpoint 0] [internal] => true 12:30:40.340 CNTRLR [Node 033] AlarmSensorCC: skipping interview because Notification CC is suppor ted... 12:30:40.341 CNTRLR [Node 033] [~] [Alarm Sensor] interviewComplete: true [Endpoint 0] [internal] => true 12:30:40.342 CNTRLR [Node 033] AssociationCC: doing a partial interview... 12:30:40.342 CNTRLR [Node 033] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 12:30:40.342 CNTRLR [Node 033] [~] [Association] interviewComplete: true = [Endpoint 0] [internal] > true 12:30:40.343 CNTRLR [Node 033] MultiChannelAssociationCC: doing a partial interview... 12:30:40.343 CNTRLR » [Node 033] querying multi channel association group #1... 12:30:40.348 SERIAL » 0x010a001321038e020125d2be (12 bytes) 12:30:40.348 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 210 └─[MultiChannelAssociationCCGet] group id: 1 12:30:40.351 SERIAL « [ACK] (0x06) 12:30:40.356 SERIAL « 0x0104011301e8 (6 bytes) 12:30:40.357 SERIAL » [ACK] (0x06) 12:30:40.357 DRIVER « [RES] [SendData] was sent: true 12:30:40.430 SERIAL « 0x01070013d200000831 (9 bytes) 12:30:40.430 SERIAL » [ACK] (0x06) 12:30:40.431 DRIVER « [REQ] [SendData] callback id: 210 transmit status: OK 12:30:40.504 SERIAL « 0x010e00040021088e0301010000010050 (16 bytes) 12:30:40.505 SERIAL » [ACK] (0x06) 12:30:40.505 CNTRLR [Node 033] [~] [Multi Channel Association] maxNodes[1]: 1 => 1 12:30:40.506 CNTRLR [Node 033] [~] [Multi Channel Association] nodeIds[1]: => 12:30:40.508 CNTRLR [Node 033] [~] [Multi Channel Association] endpoints[1]: [object Object] => [o bject Object] 12:30:40.509 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 1 node ids: endpoints: 1:0 12:30:40.511 CNTRLR « [Node 033] received information for multi channel association group #1: maximum # of nodes: 1 currently assigned nodes: currently assigned endpoints: 1:0 12:30:40.511 CNTRLR » [Node 033] querying multi channel association group #2... 12:30:40.515 SERIAL » 0x010a001321038e020225d3bc (12 bytes) 12:30:40.515 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 211 └─[MultiChannelAssociationCCGet] group id: 2 12:30:40.517 SERIAL « [ACK] (0x06) 12:30:40.525 SERIAL « 0x0104011301e8 (6 bytes) 12:30:40.526 SERIAL » [ACK] (0x06) 12:30:40.528 DRIVER « [RES] [SendData] was sent: true 12:30:40.610 SERIAL « 0x01070013d300000931 (9 bytes) 12:30:40.610 SERIAL » [ACK] (0x06) 12:30:40.611 DRIVER « [REQ] [SendData] callback id: 211 transmit status: OK 12:30:40.683 SERIAL « 0x010b00040021058e03020a0051 (13 bytes) 12:30:40.684 SERIAL » [ACK] (0x06) 12:30:40.685 CNTRLR [Node 033] [~] [Multi Channel Association] maxNodes[2]: 10 => 10 12:30:40.686 CNTRLR [Node 033] [~] [Multi Channel Association] nodeIds[2]: => 12:30:40.687 CNTRLR [Node 033] [~] [Multi Channel Association] endpoints[2]: => 12:30:40.688 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 10 node ids: endpoints: 12:30:40.691 CNTRLR « [Node 033] received information for multi channel association group #2: maximum # of nodes: 10 currently assigned nodes: currently assigned endpoints: 12:30:40.691 CNTRLR » [Node 033] querying multi channel association group #3... 12:30:40.696 SERIAL » 0x010a001321038e020325d4ba (12 bytes) 12:30:40.697 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 212 └─[MultiChannelAssociationCCGet] group id: 3 12:30:40.700 SERIAL « [ACK] (0x06) 12:30:40.706 SERIAL « 0x0104011301e8 (6 bytes) 12:30:40.707 SERIAL » [ACK] (0x06) 12:30:40.708 DRIVER « [RES] [SendData] was sent: true 12:30:40.790 SERIAL « 0x01070013d400000936 (9 bytes) 12:30:40.791 SERIAL » [ACK] (0x06) 12:30:40.791 DRIVER « [REQ] [SendData] callback id: 212 transmit status: OK 12:30:40.863 SERIAL « 0x010b00040021058e03030a0050 (13 bytes) 12:30:40.864 SERIAL » [ACK] (0x06) 12:30:40.865 CNTRLR [Node 033] [~] [Multi Channel Association] maxNodes[3]: 10 => 10 12:30:40.866 CNTRLR [Node 033] [~] [Multi Channel Association] nodeIds[3]: => 12:30:40.867 CNTRLR [Node 033] [~] [Multi Channel Association] endpoints[3]: => 12:30:40.867 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 3 maximum # of nodes: 10 node ids: endpoints: 12:30:40.869 CNTRLR « [Node 033] received information for multi channel association group #3: maximum # of nodes: 10 currently assigned nodes: currently assigned endpoints: 12:30:40.872 CNTRLR » [Node 033] querying multi channel association group #4... 12:30:40.876 SERIAL » 0x010a001321038e020425d5bc (12 bytes) 12:30:40.876 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 213 └─[MultiChannelAssociationCCGet] group id: 4 12:30:40.878 SERIAL « [ACK] (0x06) 12:30:40.885 SERIAL « 0x0104011301e8 (6 bytes) 12:30:40.886 SERIAL » [ACK] (0x06) 12:30:40.887 DRIVER « [RES] [SendData] was sent: true 12:30:40.970 SERIAL « 0x01070013d500000937 (9 bytes) 12:30:40.971 SERIAL » [ACK] (0x06) 12:30:40.971 DRIVER « [REQ] [SendData] callback id: 213 transmit status: OK 12:30:41.043 SERIAL « 0x010b00040021058e03040a0057 (13 bytes) 12:30:41.045 SERIAL » [ACK] (0x06) 12:30:41.046 CNTRLR [Node 033] [~] [Multi Channel Association] maxNodes[4]: 10 => 10 12:30:41.048 CNTRLR [Node 033] [~] [Multi Channel Association] nodeIds[4]: => 12:30:41.050 CNTRLR [Node 033] [~] [Multi Channel Association] endpoints[4]: => 12:30:41.052 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 4 maximum # of nodes: 10 node ids: endpoints: 12:30:41.055 CNTRLR « [Node 033] received information for multi channel association group #4: maximum # of nodes: 10 currently assigned nodes: currently assigned endpoints: 12:30:41.055 CNTRLR » [Node 033] querying multi channel association group #5... 12:30:41.064 SERIAL » 0x010a001321038e020525d6be (12 bytes) 12:30:41.065 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 214 └─[MultiChannelAssociationCCGet] group id: 5 12:30:41.069 SERIAL « [ACK] (0x06) 12:30:41.077 SERIAL « 0x0104011301e8 (6 bytes) 12:30:41.080 SERIAL » [ACK] (0x06) 12:30:41.089 DRIVER « [RES] [SendData] was sent: true 12:30:41.150 SERIAL « 0x01070013d600000835 (9 bytes) 12:30:41.150 SERIAL » [ACK] (0x06) 12:30:41.151 DRIVER « [REQ] [SendData] callback id: 214 transmit status: OK 12:30:41.223 SERIAL « 0x010b00040021058e03050a0056 (13 bytes) 12:30:41.224 SERIAL » [ACK] (0x06) 12:30:41.225 CNTRLR [Node 033] [~] [Multi Channel Association] maxNodes[5]: 10 => 10 12:30:41.227 CNTRLR [Node 033] [~] [Multi Channel Association] nodeIds[5]: => 12:30:41.228 CNTRLR [Node 033] [~] [Multi Channel Association] endpoints[5]: => 12:30:41.230 DRIVER « [Node 033] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 5 maximum # of nodes: 10 node ids: endpoints: 12:30:41.232 CNTRLR « [Node 033] received information for multi channel association group #5: maximum # of nodes: 10 currently assigned nodes: currently assigned endpoints: 12:30:41.232 CNTRLR [Node 033] [~] [Association] hasLifeline: true => true [internal] 12:30:41.233 CNTRLR [Node 033] [~] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true => true 12:30:41.263 CNTRLR [Node 033] AssociationGroupInfoCC: doing a partial interview... 12:30:41.264 CNTRLR [Node 033] [~] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true => true 12:30:41.266 CNTRLR [Node 033] NotificationCC: doing a partial interview... 12:30:41.268 CNTRLR [Node 033] [~] [Notification] interviewComplete: true [Endpoint 0] [internal] => true 12:30:41.268 CNTRLR [Node 033] Interview stage completed: CommandClasses 12:30:41.269 CNTRLR [Node 033] Interview stage completed: OverwriteConfig 12:30:41.269 CNTRLR » [Node 033] requesting node neighbors... 12:30:41.274 SERIAL » 0x010700802100000059 (9 bytes) 12:30:41.274 DRIVER » [Node 033] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 12:30:41.277 SERIAL « [ACK] (0x06) 12:30:41.279 SERIAL « 0x01200180010040000000000000000000000000000000000000000000000000000 (34 bytes) 01f 12:30:41.280 SERIAL » [ACK] (0x06) 12:30:41.281 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 23 12:30:41.284 CNTRLR « [Node 033] node neighbors received: 1, 23 12:30:41.284 CNTRLR [Node 033] Interview stage completed: Neighbors 12:30:41.285 CNTRLR [Node 033] Interview completed 12:30:42.286 CNTRLR » [Node 033] Sending node back to sleep... 12:30:42.292 SERIAL » 0x010900132102840825d7b8 (11 bytes) 12:30:42.292 DRIVER » [Node 033] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 215 └─[WakeUpCCNoMoreInformation] 12:30:42.294 SERIAL « [ACK] (0x06) 12:30:42.301 SERIAL « 0x0104011301e8 (6 bytes) 12:30:42.301 SERIAL » [ACK] (0x06) 12:30:42.302 DRIVER « [RES] [SendData] was sent: true 12:30:42.341 SERIAL « 0x01070013d700000539 (9 bytes) 12:30:42.342 SERIAL » [ACK] (0x06) 12:30:42.343 DRIVER « [REQ] [SendData] callback id: 215 transmit status: OK 12:30:42.345 CNTRLR [Node 033] The node is now asleep.