23:16:41.186 DRIVER ███████╗ ██╗ ██╗ █████╗ ██╗ ██╗ ███████╗ ██╗ ███████╗ ╚══███╔╝ ██║ ██║ ██╔══██╗ ██║ ██║ ██╔════╝ ██║ ██╔════╝ ███╔╝ ██║ █╗ ██║ ███████║ ██║ ██║ █████╗ █████╗ ██║ ███████╗ ███╔╝ ██║███╗██║ ██╔══██║ ╚██╗ ██╔╝ ██╔══╝ ╚════╝ ██ ██║ ╚════██║ ███████╗ ╚███╔███╔╝ ██║ ██║ ╚████╔╝ ███████╗ ╚█████╔╝ ███████║ ╚══════╝ ╚══╝╚══╝ ╚═╝ ╚═╝ ╚═══╝ ╚══════╝ ╚════╝ ╚══════╝ 23:16:41.188 DRIVER version 5.5.0 23:16:41.189 DRIVER 23:16:41.189 DRIVER starting driver... 23:16:41.197 DRIVER Send queue: (empty) (0 messages) 23:16:41.198 DRIVER send thread state: idle 23:16:41.198 DRIVER opening serial port /dev/serial/by-id/usb-0658_0200-if00 23:16:41.234 DRIVER serial port opened 23:16:41.236 SERIAL » [NAK] (0x15) 23:16:41.243 SERIAL « 0x01140004000f0e320221340000022a000000000000e3 (22 bytes) 23:16:41.245 DRIVER Dropping message because the driver is not ready to handle it yet. ... 13:52:03.388 SERIAL « 0x01140004000f0e320221340000015800000000000092 (22 bytes) 13:52:03.389 CNTRLR [Node 015] [~] [Meter] value[66049]: 28.7 => 34.4 [Endpoint 0] 13:52:03.389 CNTRLR [Node 015] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:52:03.390 SERIAL » [ACK] (0x06) 13:52:03.391 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 34.4 time delta: 0 seconds 13:52:03.391 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:03.392 DRIVER send thread state: idle 13:52:03.392 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:03.392 DRIVER send thread state: idle 13:52:03.502 SERIAL « 0x010c000400360631050422051ccc (14 bytes) 13:52:03.503 CNTRLR [Node 054] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 13:52:03.503 CNTRLR [Node 054] [~] [Multilevel Sensor] Power: 109.2 => 130.8 [Endpoint 0] 13:52:03.504 SERIAL » [ACK] (0x06) 13:52:03.505 DRIVER « [Node 054] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 130.8 13:52:03.505 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:03.507 DRIVER send thread state: idle 13:52:03.508 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:03.508 DRIVER send thread state: idle 13:52:05.389 SERIAL « 0x01140004000f0e3202213400000137000000000000fd (22 bytes) 13:52:05.389 CNTRLR [Node 015] [~] [Meter] value[66049]: 34.4 => 31.1 [Endpoint 0] 13:52:05.390 CNTRLR [Node 015] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:52:05.390 SERIAL » [ACK] (0x06) 13:52:05.391 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 31.1 time delta: 0 seconds 13:52:05.392 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:05.392 DRIVER send thread state: idle 13:52:05.393 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:05.393 DRIVER send thread state: idle 13:52:06.132 SERIAL « 0x0114000400100e3202213400000113000000000000c6 (22 bytes) 13:52:06.132 CNTRLR [Node 016] [~] [Meter] value[66049]: 27.8 => 27.5 [Endpoint 0] 13:52:06.133 CNTRLR [Node 016] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:52:06.133 SERIAL » [ACK] (0x06) 13:52:06.134 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 27.5 time delta: 0 seconds 13:52:06.135 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:06.136 DRIVER send thread state: idle 13:52:06.136 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:06.136 DRIVER send thread state: idle 13:52:09.905 SERIAL « 0x01100004003e0a32022134000000000000fa (18 bytes) 13:52:09.906 CNTRLR [Node 062] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 13:52:09.906 CNTRLR [Node 062] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:52:09.907 SERIAL » [ACK] (0x06) 13:52:09.908 DRIVER « [Node 062] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 13:52:09.909 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:09.909 DRIVER send thread state: idle 13:52:09.909 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:09.909 DRIVER send thread state: idle 13:52:11.388 SERIAL « 0x01140004000f0e320221340000011e000000000000d4 (22 bytes) 13:52:11.389 CNTRLR [Node 015] [~] [Meter] value[66049]: 31.1 => 28.6 [Endpoint 0] 13:52:11.389 CNTRLR [Node 015] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:52:11.390 SERIAL » [ACK] (0x06) 13:52:11.390 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 28.6 time delta: 0 seconds 13:52:11.390 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:11.391 DRIVER send thread state: idle 13:52:11.391 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:11.391 DRIVER send thread state: idle 13:52:11.502 SERIAL « 0x010c00040036063105042203bb6d (14 bytes) 13:52:11.502 CNTRLR [Node 054] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 13:52:11.502 CNTRLR [Node 054] [~] [Multilevel Sensor] Power: 130.8 => 95.5 [Endpoint 0] 13:52:11.502 SERIAL » [ACK] (0x06) 13:52:11.503 DRIVER « [Node 054] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 95.5 13:52:11.503 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:11.504 DRIVER send thread state: idle 13:52:11.504 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:11.504 DRIVER send thread state: idle 13:52:14.419 SERIAL « 0x01100004001c0a32022134000000000000d8 (18 bytes) 13:52:14.419 CNTRLR [Node 028] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 13:52:14.420 CNTRLR [Node 028] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:52:14.420 SERIAL » [ACK] (0x06) 13:52:14.421 DRIVER « [Node 028] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 13:52:14.422 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:14.422 DRIVER send thread state: idle 13:52:14.423 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:14.423 DRIVER send thread state: idle 13:52:15.727 CNTRLR [Node 006] Beginning interview - last completed stage: None 13:52:15.727 CNTRLR [Node 006] new node, doing a full interview... 13:52:15.727 CNTRLR » [Node 006] querying protocol info... 13:52:15.728 DRIVER Send queue: (2 messages) · [REQ] GetNodeProtocolInfo · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:15.731 SERIAL » 0x0104004106bc (6 bytes) 13:52:15.731 DRIVER » [REQ] [GetNodeProtocolInfo] payload: 0x06 13:52:15.731 DRIVER send thread state: sending.execute 13:52:15.732 SERIAL « [ACK] (0x06) 13:52:15.733 DRIVER send thread state: sending.execute 13:52:15.733 SERIAL « 0x01090141d39c01041001ed (11 bytes) 13:52:15.734 SERIAL » [ACK] (0x06) 13:52:15.734 DRIVER « [RES] [GetNodeProtocolInfo] payload: 0xd39c01041001 13:52:15.735 DRIVER send thread state: sending.execute 13:52:15.735 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:15.735 DRIVER send thread state: idle 13:52:15.735 CNTRLR « [Node 006] received response for protocol info: basic device class: Static Controller generic device class: Binary Switch specific device class: Binary Power Switch is a listening device: true is frequent listening: false is a routing device: true is a secure device: unknown is a beaming device: true maximum baud rate: 40000 kbps version: 4 13:52:15.735 CNTRLR [Node 006] Interview stage completed: ProtocolInfo 13:52:15.735 CNTRLR » [Node 006] pinging the node... 13:52:15.736 DRIVER Send queue: (2 messages) · [REQ] SendData (NoOperationCC) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:15.738 SERIAL » 0x01080013060100259751 (10 bytes) 13:52:15.738 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 151 └─[NoOperationCC] 13:52:15.738 DRIVER send thread state: sending.execute 13:52:15.739 SERIAL « [ACK] (0x06) 13:52:15.739 DRIVER send thread state: sending.execute 13:52:15.745 SERIAL « 0x0104011301e8 (6 bytes) 13:52:15.745 SERIAL » [ACK] (0x06) 13:52:15.745 DRIVER « [RES] [SendData] was sent: true 13:52:15.747 DRIVER send thread state: sending.execute 13:52:15.761 SERIAL « 0x01070013970000027e (9 bytes) 13:52:15.762 SERIAL » [ACK] (0x06) 13:52:15.762 DRIVER « [REQ] [SendData] callback id: 151 transmit status: OK 13:52:15.762 DRIVER send thread state: sending.execute 13:52:15.763 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:15.763 DRIVER send thread state: idle 13:52:15.763 CNTRLR « [Node 006] ping successful 13:52:15.763 CNTRLR » [Node 006] querying node info... 13:52:15.764 DRIVER Send queue: (2 messages) · [REQ] RequestNodeInfo [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:15.764 SERIAL » 0x01040060069d (6 bytes) 13:52:15.765 DRIVER » [Node 006] [REQ] [RequestNodeInfo] payload: 0x06 13:52:15.765 DRIVER send thread state: sending.execute 13:52:15.766 SERIAL « [ACK] (0x06) 13:52:15.766 DRIVER send thread state: sending.execute 13:52:15.772 SERIAL « 0x01040160019b (6 bytes) 13:52:15.772 SERIAL » [ACK] (0x06) 13:52:15.774 DRIVER « [RES] [RequestNodeInfo] payload: 0x01 13:52:15.774 DRIVER send thread state: sending.execute 13:52:15.805 SERIAL « 0x011e00498406180410015e8672255a5985735670328e60227571987a5bef26f1 (32 bytes) 13:52:15.806 SERIAL » [ACK] (0x06) 13:52:15.807 DRIVER « [Node 006] [REQ] [ApplicationUpdateRequest] payload: 0x8406180410015e8672255a5985735670328e60227571987a5bef26 13:52:15.809 DRIVER send thread state: sending.execute 13:52:15.809 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:15.809 DRIVER send thread state: idle 13:52:15.810 CNTRLR « [Node 006] node info received supported CCs: · Z-Wave Plus Info · Version · Manufacturer Specific · Binary Switch · Device Reset Locally · Association Group Information · Association · Powerlevel · CRC-16 Encapsulation · Configuration · Meter · Multi Channel Association · Multi Channel · Application Status · Protection · Notification · Security · Firmware Update Meta Data · Central Scene controlled CCs: · Multilevel Switch 13:52:15.811 CNTRLR [Node 006] Interview stage completed: NodeInfo 13:52:15.811 CNTRLR » [Node 006] querying securely supported commands... 13:52:15.814 DRIVER Send queue: (2 messages) · [REQ] SendData (SecurityCCCommandEncapsulation) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:15.818 DRIVER send thread state: sending.handshake.waitForCommandResult 13:52:15.823 SERIAL » 0x0109001306029840259884 (11 bytes) 13:52:15.823 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 152 └─[SecurityCCNonceGet] 13:52:15.824 DRIVER send thread state: sending.handshake.waitForCommandResult 13:52:15.825 SERIAL « [ACK] (0x06) 13:52:15.826 DRIVER send thread state: sending.handshake.waitForCommandResult 13:52:15.832 SERIAL « 0x0104011301e8 (6 bytes) 13:52:15.832 SERIAL » [ACK] (0x06) 13:52:15.832 DRIVER « [RES] [SendData] was sent: true 13:52:15.834 DRIVER send thread state: sending.handshake.waitForCommandResult 13:52:15.848 SERIAL « 0x010700139800000271 (9 bytes) 13:52:15.848 SERIAL » [ACK] (0x06) 13:52:15.849 DRIVER « [REQ] [SendData] callback id: 152 transmit status: OK 13:52:15.851 DRIVER send thread state: sending.handshake.waitForCommandResult 13:52:15.851 DRIVER send thread state: sending.handshake.waitForHandshakeResponse 13:52:16.131 SERIAL « 0x0114000400100e3202213400000118000000000000cd (22 bytes) 13:52:16.132 CNTRLR [Node 016] [~] [Meter] value[66049]: 27.5 => 28 [Endpoint 0] 13:52:16.133 CNTRLR [Node 016] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:52:16.133 SERIAL » [ACK] (0x06) 13:52:16.134 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 28 time delta: 0 seconds 13:52:16.134 DRIVER send thread state: sending.handshake.waitForHandshakeResponse 13:52:16.135 DRIVER send thread state: sending.handshake.waitForHandshakeResponse 13:52:17.454 CNTRLR [Node 006] did not respond after 1/3 attempts. Scheduling next try in 500 ms. 13:52:17.454 DRIVER send thread state: sending.retryWait 13:52:17.502 SERIAL « 0x010c000400360631050422047cad (14 bytes) 13:52:17.503 CNTRLR [Node 054] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 13:52:17.503 CNTRLR [Node 054] [~] [Multilevel Sensor] Power: 95.5 => 114.8 [Endpoint 0] 13:52:17.505 SERIAL » [ACK] (0x06) 13:52:17.505 DRIVER « [Node 054] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 114.8 13:52:17.506 DRIVER send thread state: sending.retryWait 13:52:17.507 DRIVER send thread state: sending.retryWait 13:52:17.957 DRIVER send thread state: sending.handshake.waitForCommandResult 13:52:17.959 SERIAL » 0x0109001306029840259985 (11 bytes) 13:52:17.960 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 153 └─[SecurityCCNonceGet] 13:52:17.960 DRIVER send thread state: sending.handshake.waitForCommandResult 13:52:17.961 SERIAL « [ACK] (0x06) 13:52:17.962 DRIVER send thread state: sending.handshake.waitForCommandResult 13:52:17.967 SERIAL « 0x0104011301e8 (6 bytes) 13:52:17.967 SERIAL » [ACK] (0x06) 13:52:17.968 DRIVER « [RES] [SendData] was sent: true 13:52:17.968 DRIVER send thread state: sending.handshake.waitForCommandResult 13:52:17.983 SERIAL « 0x010700139900000270 (9 bytes) 13:52:17.984 SERIAL » [ACK] (0x06) 13:52:17.984 DRIVER « [REQ] [SendData] callback id: 153 transmit status: OK 13:52:17.986 DRIVER send thread state: sending.handshake.waitForCommandResult 13:52:17.986 DRIVER send thread state: sending.handshake.waitForHandshakeResponse 13:52:19.588 CNTRLR [Node 006] did not respond after 2/3 attempts. Scheduling next try in 500 ms. 13:52:19.588 DRIVER send thread state: sending.retryWait 13:52:20.090 DRIVER send thread state: sending.handshake.waitForCommandResult 13:52:20.092 SERIAL » 0x0109001306029840259a86 (11 bytes) 13:52:20.093 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 154 └─[SecurityCCNonceGet] 13:52:20.093 DRIVER send thread state: sending.handshake.waitForCommandResult 13:52:20.095 SERIAL « [ACK] (0x06) 13:52:20.095 DRIVER send thread state: sending.handshake.waitForCommandResult 13:52:20.101 SERIAL « 0x0104011301e8 (6 bytes) 13:52:20.101 SERIAL » [ACK] (0x06) 13:52:20.101 DRIVER « [RES] [SendData] was sent: true 13:52:20.103 DRIVER send thread state: sending.handshake.waitForCommandResult 13:52:20.119 SERIAL « 0x010700139a00000273 (9 bytes) 13:52:20.119 SERIAL » [ACK] (0x06) 13:52:20.120 DRIVER « [REQ] [SendData] callback id: 154 transmit status: OK 13:52:20.121 DRIVER send thread state: sending.handshake.waitForCommandResult 13:52:20.121 DRIVER send thread state: sending.handshake.waitForHandshakeResponse 13:52:20.388 SERIAL « 0x01140004000f0e320221340000011b000000000000d1 (22 bytes) 13:52:20.390 CNTRLR [Node 015] [~] [Meter] value[66049]: 28.6 => 28.3 [Endpoint 0] 13:52:20.390 CNTRLR [Node 015] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:52:20.391 SERIAL » [ACK] (0x06) 13:52:20.392 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 28.3 time delta: 0 seconds 13:52:20.393 DRIVER send thread state: sending.handshake.waitForHandshakeResponse 13:52:20.393 DRIVER send thread state: sending.handshake.waitForHandshakeResponse 13:52:21.131 SERIAL « 0x0114000400100e3202213400000115000000000000c0 (22 bytes) 13:52:21.132 CNTRLR [Node 016] [~] [Meter] value[66049]: 28 => 27.7 [Endpoint 0] 13:52:21.132 CNTRLR [Node 016] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:52:21.133 SERIAL » [ACK] (0x06) 13:52:21.133 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 27.7 time delta: 0 seconds 13:52:21.134 DRIVER send thread state: sending.handshake.waitForHandshakeResponse 13:52:21.135 DRIVER send thread state: sending.handshake.waitForHandshakeResponse 13:52:21.722 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:21.723 DRIVER send thread state: idle 13:52:21.723 CNTRLR [Node 006] The node is not included securely. Continuing interview non-securel y. 13:52:21.727 CNTRLR [Node 006] ManufacturerSpecificCC: doing a complete interview... 13:52:21.727 CNTRLR » [Node 006] querying manufacturer information... 13:52:21.727 DRIVER Send queue: (2 messages) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:21.729 SERIAL » 0x0109001306027204259b29 (11 bytes) 13:52:21.729 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 155 └─[ManufacturerSpecificCCGet] 13:52:21.729 DRIVER send thread state: sending.execute 13:52:21.730 SERIAL « [ACK] (0x06) 13:52:21.731 DRIVER send thread state: sending.execute 13:52:21.736 SERIAL « 0x0104011301e8 (6 bytes) 13:52:21.737 SERIAL » [ACK] (0x06) 13:52:21.737 DRIVER « [RES] [SendData] was sent: true 13:52:21.738 DRIVER send thread state: sending.execute 13:52:21.753 SERIAL « 0x010700139b00000272 (9 bytes) 13:52:21.753 SERIAL » [ACK] (0x06) 13:52:21.753 DRIVER « [REQ] [SendData] callback id: 155 transmit status: OK 13:52:21.755 DRIVER send thread state: sending.execute 13:52:21.755 DRIVER send thread state: sending.waitForUpdate 13:52:21.765 SERIAL « 0x010e00040006087205010f0203100093 (16 bytes) 13:52:21.766 CNTRLR [Node 006] [+] [Manufacturer Specific] manufacturerId: 271 [Endpoint 0] 13:52:21.767 CNTRLR [Node 006] [+] [Manufacturer Specific] productType: 515 [Endpoint 0] 13:52:21.767 CNTRLR [Node 006] [+] [Manufacturer Specific] productId: 4096 [Endpoint 0] 13:52:21.768 SERIAL » [ACK] (0x06) 13:52:21.769 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ManufacturerSpecificCCReport] manufacturer id: 0x010f product type: 0x0203 product id: 0x1000 13:52:21.771 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:21.771 DRIVER send thread state: idle 13:52:21.771 CNTRLR « [Node 006] received response for manufacturer information: manufacturer: Fibargroup (0x010f) product type: 0x0203 product id: 0x1000 13:52:21.771 CNTRLR [Node 006] [+] [Manufacturer Specific] interviewComple [Endpoint 0] [internal] te: true 13:52:21.779 CNTRLR [Node 006] VersionCC: doing a complete interview... 13:52:21.779 CNTRLR » [Node 006] querying node versions... 13:52:21.780 DRIVER Send queue: (2 messages) · [REQ] SendData (VersionCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:21.782 SERIAL » 0x0109001306028611259ccf (11 bytes) 13:52:21.782 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 156 └─[VersionCCGet] 13:52:21.782 DRIVER send thread state: sending.execute 13:52:21.783 SERIAL « [ACK] (0x06) 13:52:21.783 DRIVER send thread state: sending.execute 13:52:21.790 SERIAL « 0x0104011301e8 (6 bytes) 13:52:21.790 SERIAL » [ACK] (0x06) 13:52:21.790 DRIVER « [RES] [SendData] was sent: true 13:52:21.790 DRIVER send thread state: sending.execute 13:52:21.806 SERIAL « 0x010700139c00000374 (9 bytes) 13:52:21.806 SERIAL » [ACK] (0x06) 13:52:21.806 DRIVER « [REQ] [SendData] callback id: 156 transmit status: OK 13:52:21.808 DRIVER send thread state: sending.execute 13:52:21.808 DRIVER send thread state: sending.waitForUpdate 13:52:21.818 SERIAL « 0x010f000400060986120304180303030073 (17 bytes) 13:52:21.819 CNTRLR [Node 006] [+] [Version] libraryType: 3 [Endpoint 0] 13:52:21.820 CNTRLR [Node 006] [+] [Version] protocolVersion: "4.24" [Endpoint 0] 13:52:21.820 CNTRLR [Node 006] [+] [Version] firmwareVersions: 3.3 [Endpoint 0] 13:52:21.820 SERIAL » [ACK] (0x06) 13:52:21.821 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCReport] library type: Enhanced Slave protocol version: 4.24 firmware versions: 3.3 13:52:21.824 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:21.824 DRIVER send thread state: idle 13:52:21.824 CNTRLR « [Node 006] received response for node versions: library type: Enhanced Slave (0x03) protocol version: 4.24 firmware versions: 3.3 13:52:21.825 CNTRLR » [Node 006] querying CC versions... 13:52:21.825 CNTRLR » [Node 006] querying the CC version for Binary Switch... 13:52:21.827 DRIVER Send queue: (2 messages) · [REQ] SendData (VersionCCCommandClassGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:21.829 SERIAL » 0x010a00130603861325259deb (12 bytes) 13:52:21.830 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 157 └─[VersionCCCommandClassGet] CC: Binary Switch 13:52:21.830 DRIVER send thread state: sending.execute 13:52:21.831 SERIAL « [ACK] (0x06) 13:52:21.832 DRIVER send thread state: sending.execute 13:52:21.838 SERIAL « 0x0104011301e8 (6 bytes) 13:52:21.838 SERIAL » [ACK] (0x06) 13:52:21.839 DRIVER « [RES] [SendData] was sent: true 13:52:21.840 DRIVER send thread state: sending.execute 13:52:21.854 SERIAL « 0x010700139d00000274 (9 bytes) 13:52:21.854 SERIAL » [ACK] (0x06) 13:52:21.855 DRIVER « [REQ] [SendData] callback id: 157 transmit status: OK 13:52:21.857 DRIVER send thread state: sending.execute 13:52:21.857 DRIVER send thread state: sending.waitForUpdate 13:52:21.865 SERIAL « 0x010a00040006048614250145 (12 bytes) 13:52:21.866 SERIAL » [ACK] (0x06) 13:52:21.867 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Binary Switch version: 1 13:52:21.868 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:21.868 DRIVER send thread state: idle 13:52:21.869 CNTRLR [Node 006] supports CC Binary Switch (0x25) in version 1 13:52:21.869 CNTRLR [Node 006] skipping query for All Switch (0x27) because max implemented vers ion is 0 13:52:21.869 CNTRLR » [Node 006] querying the CC version for Z-Wave Plus Info... 13:52:21.871 DRIVER Send queue: (2 messages) · [REQ] SendData (VersionCCCommandClassGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:21.873 SERIAL » 0x010a0013060386135e259e93 (12 bytes) 13:52:21.874 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 158 └─[VersionCCCommandClassGet] CC: Z-Wave Plus Info 13:52:21.874 DRIVER send thread state: sending.execute 13:52:21.875 SERIAL « [ACK] (0x06) 13:52:21.876 DRIVER send thread state: sending.execute 13:52:21.882 SERIAL « 0x0104011301e8 (6 bytes) 13:52:21.882 SERIAL » [ACK] (0x06) 13:52:21.883 DRIVER « [RES] [SendData] was sent: true 13:52:21.886 DRIVER send thread state: sending.execute 13:52:21.898 SERIAL « 0x010700139e00000277 (9 bytes) 13:52:21.899 SERIAL » [ACK] (0x06) 13:52:21.899 DRIVER « [REQ] [SendData] callback id: 158 transmit status: OK 13:52:21.901 DRIVER send thread state: sending.execute 13:52:21.901 DRIVER send thread state: sending.waitForUpdate 13:52:21.910 SERIAL « 0x010a000400060486145e023d (12 bytes) 13:52:21.910 SERIAL » [ACK] (0x06) 13:52:21.911 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Z-Wave Plus Info version: 2 13:52:21.911 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:21.912 DRIVER send thread state: idle 13:52:21.912 CNTRLR [Node 006] supports CC Z-Wave Plus Info (0x5e) in version 2 13:52:21.912 CNTRLR » [Node 006] querying the CC version for Version... 13:52:21.914 DRIVER Send queue: (2 messages) · [REQ] SendData (VersionCCCommandClassGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:21.916 SERIAL » 0x010a00130603861386259f4a (12 bytes) 13:52:21.917 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 159 └─[VersionCCCommandClassGet] CC: Version 13:52:21.917 DRIVER send thread state: sending.execute 13:52:21.918 SERIAL « [ACK] (0x06) 13:52:21.919 DRIVER send thread state: sending.execute 13:52:21.925 SERIAL « 0x0104011301e8 (6 bytes) 13:52:21.925 SERIAL » [ACK] (0x06) 13:52:21.926 DRIVER « [RES] [SendData] was sent: true 13:52:21.927 DRIVER send thread state: sending.execute 13:52:21.941 SERIAL « 0x010700139f00000276 (9 bytes) 13:52:21.942 SERIAL » [ACK] (0x06) 13:52:21.942 DRIVER « [REQ] [SendData] callback id: 159 transmit status: OK 13:52:21.944 DRIVER send thread state: sending.execute 13:52:21.945 DRIVER send thread state: sending.waitForUpdate 13:52:21.952 SERIAL « 0x010a000400060486148602e5 (12 bytes) 13:52:21.953 SERIAL » [ACK] (0x06) 13:52:21.953 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Version version: 2 13:52:21.954 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:21.955 DRIVER send thread state: idle 13:52:21.957 CNTRLR [Node 006] supports CC Version (0x86) in version 2 13:52:21.958 CNTRLR » [Node 006] querying the CC version for Manufacturer Specific... 13:52:21.959 DRIVER Send queue: (2 messages) · [REQ] SendData (VersionCCCommandClassGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:21.962 SERIAL » 0x010a0013060386137225a081 (12 bytes) 13:52:21.962 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 160 └─[VersionCCCommandClassGet] CC: Manufacturer Specific 13:52:21.962 DRIVER send thread state: sending.execute 13:52:21.964 SERIAL « [ACK] (0x06) 13:52:21.965 DRIVER send thread state: sending.execute 13:52:21.971 SERIAL « 0x0104011301e8 (6 bytes) 13:52:21.971 SERIAL » [ACK] (0x06) 13:52:21.971 DRIVER « [RES] [SendData] was sent: true 13:52:21.973 DRIVER send thread state: sending.execute 13:52:21.987 SERIAL « 0x01070013a000000249 (9 bytes) 13:52:21.987 SERIAL » [ACK] (0x06) 13:52:21.988 DRIVER « [REQ] [SendData] callback id: 160 transmit status: OK 13:52:21.989 DRIVER send thread state: sending.execute 13:52:21.990 DRIVER send thread state: sending.waitForUpdate 13:52:21.998 SERIAL « 0x010a00040006048614720211 (12 bytes) 13:52:21.999 SERIAL » [ACK] (0x06) 13:52:21.999 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Manufacturer Specific version: 2 13:52:22.000 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.000 DRIVER send thread state: idle 13:52:22.001 CNTRLR [Node 006] supports CC Manufacturer Specific (0x72) in version 2 13:52:22.001 CNTRLR [Node 006] skipping query for Device Reset Locally (0x5a) because max implem ented version is 1 13:52:22.001 CNTRLR » [Node 006] querying the CC version for Association Group Information... 13:52:22.002 DRIVER Send queue: (2 messages) · [REQ] SendData (VersionCCCommandClassGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.005 SERIAL » 0x010a0013060386135925a1ab (12 bytes) 13:52:22.005 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 161 └─[VersionCCCommandClassGet] CC: Association Group Information 13:52:22.005 DRIVER send thread state: sending.execute 13:52:22.007 SERIAL « [ACK] (0x06) 13:52:22.007 DRIVER send thread state: sending.execute 13:52:22.013 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.013 SERIAL » [ACK] (0x06) 13:52:22.014 DRIVER « [RES] [SendData] was sent: true 13:52:22.017 DRIVER send thread state: sending.execute 13:52:22.030 SERIAL « 0x01070013a100000248 (9 bytes) 13:52:22.030 SERIAL » [ACK] (0x06) 13:52:22.030 DRIVER « [REQ] [SendData] callback id: 161 transmit status: OK 13:52:22.032 DRIVER send thread state: sending.execute 13:52:22.032 DRIVER send thread state: sending.waitForUpdate 13:52:22.041 SERIAL « 0x010a00040006048614590139 (12 bytes) 13:52:22.041 SERIAL » [ACK] (0x06) 13:52:22.042 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association Group Information version: 1 13:52:22.043 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.043 DRIVER send thread state: idle 13:52:22.043 CNTRLR [Node 006] supports CC Association Group Information (0x59) in version 1 13:52:22.043 CNTRLR » [Node 006] querying the CC version for Association... 13:52:22.045 DRIVER Send queue: (2 messages) · [REQ] SendData (VersionCCCommandClassGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.047 SERIAL » 0x010a0013060386138525a274 (12 bytes) 13:52:22.047 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 162 └─[VersionCCCommandClassGet] CC: Association 13:52:22.048 DRIVER send thread state: sending.execute 13:52:22.049 SERIAL « [ACK] (0x06) 13:52:22.050 DRIVER send thread state: sending.execute 13:52:22.056 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.056 SERIAL » [ACK] (0x06) 13:52:22.056 DRIVER « [RES] [SendData] was sent: true 13:52:22.058 DRIVER send thread state: sending.execute 13:52:22.072 SERIAL « 0x01070013a20000024b (9 bytes) 13:52:22.072 SERIAL » [ACK] (0x06) 13:52:22.073 DRIVER « [REQ] [SendData] callback id: 162 transmit status: OK 13:52:22.074 DRIVER send thread state: sending.execute 13:52:22.075 DRIVER send thread state: sending.waitForUpdate 13:52:22.083 SERIAL « 0x010a000400060486148502e6 (12 bytes) 13:52:22.084 SERIAL » [ACK] (0x06) 13:52:22.084 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Association version: 2 13:52:22.085 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.085 DRIVER send thread state: idle 13:52:22.086 CNTRLR [Node 006] supports CC Association (0x85) in version 2 13:52:22.086 CNTRLR [Node 006] skipping query for Powerlevel (0x73) because max implemented vers ion is 0 13:52:22.086 CNTRLR [Node 006] skipping query for CRC-16 Encapsulation (0x56) because max implem ented version is 1 13:52:22.086 CNTRLR » [Node 006] querying the CC version for Configuration... 13:52:22.089 DRIVER Send queue: (2 messages) · [REQ] SendData (VersionCCCommandClassGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.092 SERIAL » 0x010a0013060386137025a380 (12 bytes) 13:52:22.092 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 163 └─[VersionCCCommandClassGet] CC: Configuration 13:52:22.092 DRIVER send thread state: sending.execute 13:52:22.094 SERIAL « [ACK] (0x06) 13:52:22.094 DRIVER send thread state: sending.execute 13:52:22.100 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.100 SERIAL » [ACK] (0x06) 13:52:22.100 DRIVER « [RES] [SendData] was sent: true 13:52:22.101 DRIVER send thread state: sending.execute 13:52:22.116 SERIAL « 0x01070013a30000034b (9 bytes) 13:52:22.116 SERIAL » [ACK] (0x06) 13:52:22.117 DRIVER « [REQ] [SendData] callback id: 163 transmit status: OK 13:52:22.119 DRIVER send thread state: sending.execute 13:52:22.119 DRIVER send thread state: sending.waitForUpdate 13:52:22.128 SERIAL « 0x010a00040006048614700110 (12 bytes) 13:52:22.128 SERIAL » [ACK] (0x06) 13:52:22.128 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Configuration version: 1 13:52:22.129 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.130 DRIVER send thread state: idle 13:52:22.130 CNTRLR [Node 006] supports CC Configuration (0x70) in version 1 13:52:22.130 CNTRLR » [Node 006] querying the CC version for Meter... 13:52:22.132 DRIVER Send queue: (2 messages) · [REQ] SendData (VersionCCCommandClassGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.134 SERIAL » 0x010a0013060386133225a4c5 (12 bytes) 13:52:22.134 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 164 └─[VersionCCCommandClassGet] CC: Meter 13:52:22.134 DRIVER send thread state: sending.execute 13:52:22.136 SERIAL « [ACK] (0x06) 13:52:22.137 DRIVER send thread state: sending.execute 13:52:22.142 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.143 SERIAL » [ACK] (0x06) 13:52:22.143 DRIVER « [RES] [SendData] was sent: true 13:52:22.146 DRIVER send thread state: sending.execute 13:52:22.158 SERIAL « 0x01070013a40000024d (9 bytes) 13:52:22.159 SERIAL » [ACK] (0x06) 13:52:22.159 DRIVER « [REQ] [SendData] callback id: 164 transmit status: OK 13:52:22.161 DRIVER send thread state: sending.execute 13:52:22.161 DRIVER send thread state: sending.waitForUpdate 13:52:22.170 SERIAL « 0x010a00040006048614320350 (12 bytes) 13:52:22.170 SERIAL » [ACK] (0x06) 13:52:22.171 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Meter version: 3 13:52:22.171 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.172 DRIVER send thread state: idle 13:52:22.172 CNTRLR [Node 006] supports CC Meter (0x32) in version 3 13:52:22.172 CNTRLR » [Node 006] querying the CC version for Multi Channel Association... 13:52:22.174 DRIVER Send queue: (2 messages) · [REQ] SendData (VersionCCCommandClassGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.176 SERIAL » 0x010a0013060386138e25a578 (12 bytes) 13:52:22.176 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 165 └─[VersionCCCommandClassGet] CC: Multi Channel Association 13:52:22.176 DRIVER send thread state: sending.execute 13:52:22.178 SERIAL « [ACK] (0x06) 13:52:22.179 DRIVER send thread state: sending.execute 13:52:22.184 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.185 SERIAL » [ACK] (0x06) 13:52:22.185 DRIVER « [RES] [SendData] was sent: true 13:52:22.186 DRIVER send thread state: sending.execute 13:52:22.200 SERIAL « 0x01070013a50000024c (9 bytes) 13:52:22.201 SERIAL » [ACK] (0x06) 13:52:22.201 DRIVER « [REQ] [SendData] callback id: 165 transmit status: OK 13:52:22.203 DRIVER send thread state: sending.execute 13:52:22.203 DRIVER send thread state: sending.waitForUpdate 13:52:22.212 SERIAL « 0x010a000400060486148e03ec (12 bytes) 13:52:22.212 SERIAL » [ACK] (0x06) 13:52:22.213 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multi Channel Association version: 3 13:52:22.214 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.214 DRIVER send thread state: idle 13:52:22.214 CNTRLR [Node 006] supports CC Multi Channel Association (0x8e) in version 3 13:52:22.214 CNTRLR » [Node 006] querying the CC version for Multi Channel... 13:52:22.217 DRIVER Send queue: (2 messages) · [REQ] SendData (VersionCCCommandClassGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.220 SERIAL » 0x010a0013060386136025a695 (12 bytes) 13:52:22.220 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 166 └─[VersionCCCommandClassGet] CC: Multi Channel 13:52:22.220 DRIVER send thread state: sending.execute 13:52:22.222 SERIAL « [ACK] (0x06) 13:52:22.222 DRIVER send thread state: sending.execute 13:52:22.228 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.228 SERIAL » [ACK] (0x06) 13:52:22.229 DRIVER « [RES] [SendData] was sent: true 13:52:22.230 DRIVER send thread state: sending.execute 13:52:22.244 SERIAL « 0x01070013a60000024f (9 bytes) 13:52:22.245 SERIAL » [ACK] (0x06) 13:52:22.245 DRIVER « [REQ] [SendData] callback id: 166 transmit status: OK 13:52:22.247 DRIVER send thread state: sending.execute 13:52:22.247 DRIVER send thread state: sending.waitForUpdate 13:52:22.256 SERIAL « 0x010a00040006048614600405 (12 bytes) 13:52:22.256 SERIAL » [ACK] (0x06) 13:52:22.257 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multi Channel version: 4 13:52:22.258 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.258 DRIVER send thread state: idle 13:52:22.258 CNTRLR [Node 006] supports CC Multi Channel (0x60) in version 4 13:52:22.258 CNTRLR [Node 006] skipping query for Application Status (0x22) because max implemen ted version is 0 13:52:22.258 CNTRLR » [Node 006] querying the CC version for Protection... 13:52:22.260 DRIVER Send queue: (2 messages) · [REQ] SendData (VersionCCCommandClassGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.262 SERIAL » 0x010a0013060386137525a781 (12 bytes) 13:52:22.262 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 167 └─[VersionCCCommandClassGet] CC: Protection 13:52:22.263 DRIVER send thread state: sending.execute 13:52:22.264 SERIAL « [ACK] (0x06) 13:52:22.265 DRIVER send thread state: sending.execute 13:52:22.271 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.271 SERIAL » [ACK] (0x06) 13:52:22.271 DRIVER « [RES] [SendData] was sent: true 13:52:22.274 DRIVER send thread state: sending.execute 13:52:22.287 SERIAL « 0x01070013a70000024e (9 bytes) 13:52:22.287 SERIAL » [ACK] (0x06) 13:52:22.288 DRIVER « [REQ] [SendData] callback id: 167 transmit status: OK 13:52:22.289 DRIVER send thread state: sending.execute 13:52:22.290 DRIVER send thread state: sending.waitForUpdate 13:52:22.298 SERIAL « 0x010a00040006048614750216 (12 bytes) 13:52:22.299 SERIAL » [ACK] (0x06) 13:52:22.299 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Protection version: 2 13:52:22.300 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.300 DRIVER send thread state: idle 13:52:22.301 CNTRLR [Node 006] supports CC Protection (0x75) in version 2 13:52:22.301 CNTRLR » [Node 006] querying the CC version for Notification... 13:52:22.302 DRIVER Send queue: (2 messages) · [REQ] SendData (VersionCCCommandClassGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.304 SERIAL » 0x010a0013060386137125a88a (12 bytes) 13:52:22.305 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 168 └─[VersionCCCommandClassGet] CC: Notification 13:52:22.305 DRIVER send thread state: sending.execute 13:52:22.307 SERIAL « [ACK] (0x06) 13:52:22.307 DRIVER send thread state: sending.execute 13:52:22.313 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.313 SERIAL » [ACK] (0x06) 13:52:22.314 DRIVER « [RES] [SendData] was sent: true 13:52:22.315 DRIVER send thread state: sending.execute 13:52:22.329 SERIAL « 0x01070013a800000241 (9 bytes) 13:52:22.330 SERIAL » [ACK] (0x06) 13:52:22.330 DRIVER « [REQ] [SendData] callback id: 168 transmit status: OK 13:52:22.332 DRIVER send thread state: sending.execute 13:52:22.332 DRIVER send thread state: sending.waitForUpdate 13:52:22.341 SERIAL « 0x010a00040006048614710515 (12 bytes) 13:52:22.341 SERIAL » [ACK] (0x06) 13:52:22.342 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Notification version: 5 13:52:22.342 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.343 DRIVER send thread state: idle 13:52:22.343 CNTRLR [Node 006] supports CC Notification (0x71) in version 5 13:52:22.343 CNTRLR [Node 006] skipping query for Security (0x98) because max implemented versio n is 1 13:52:22.343 CNTRLR » [Node 006] querying the CC version for Firmware Update Meta Data... 13:52:22.345 DRIVER Send queue: (2 messages) · [REQ] SendData (VersionCCCommandClassGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.347 SERIAL » 0x010a0013060386137a25a980 (12 bytes) 13:52:22.348 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 169 └─[VersionCCCommandClassGet] CC: Firmware Update Meta Data 13:52:22.348 DRIVER send thread state: sending.execute 13:52:22.350 SERIAL « [ACK] (0x06) 13:52:22.350 DRIVER send thread state: sending.execute 13:52:22.356 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.356 SERIAL » [ACK] (0x06) 13:52:22.356 DRIVER « [RES] [SendData] was sent: true 13:52:22.358 DRIVER send thread state: sending.execute 13:52:22.372 SERIAL « 0x01070013a900000240 (9 bytes) 13:52:22.372 SERIAL » [ACK] (0x06) 13:52:22.373 DRIVER « [REQ] [SendData] callback id: 169 transmit status: OK 13:52:22.375 DRIVER send thread state: sending.execute 13:52:22.375 DRIVER send thread state: sending.waitForUpdate 13:52:22.384 SERIAL « 0x010a000400060486147a0318 (12 bytes) 13:52:22.384 SERIAL » [ACK] (0x06) 13:52:22.385 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Firmware Update Meta Data version: 3 13:52:22.387 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.388 DRIVER send thread state: idle 13:52:22.388 CNTRLR [Node 006] supports CC Firmware Update Meta Data (0x7a) in version 3 13:52:22.388 CNTRLR » [Node 006] querying the CC version for Central Scene... 13:52:22.390 DRIVER Send queue: (2 messages) · [REQ] SendData (VersionCCCommandClassGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.393 SERIAL » 0x010a0013060386135b25aaa2 (12 bytes) 13:52:22.393 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 170 └─[VersionCCCommandClassGet] CC: Central Scene 13:52:22.393 DRIVER send thread state: sending.execute 13:52:22.395 SERIAL « [ACK] (0x06) 13:52:22.396 DRIVER send thread state: sending.execute 13:52:22.401 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.402 SERIAL » [ACK] (0x06) 13:52:22.402 DRIVER « [RES] [SendData] was sent: true 13:52:22.404 DRIVER send thread state: sending.execute 13:52:22.417 SERIAL « 0x01070013aa00000243 (9 bytes) 13:52:22.418 SERIAL » [ACK] (0x06) 13:52:22.418 DRIVER « [REQ] [SendData] callback id: 170 transmit status: OK 13:52:22.420 DRIVER send thread state: sending.execute 13:52:22.420 DRIVER send thread state: sending.waitForUpdate 13:52:22.430 SERIAL « 0x010a000400060486145b0238 (12 bytes) 13:52:22.431 SERIAL » [ACK] (0x06) 13:52:22.431 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Central Scene version: 2 13:52:22.432 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.433 DRIVER send thread state: idle 13:52:22.433 CNTRLR [Node 006] supports CC Central Scene (0x5b) in version 2 13:52:22.433 CNTRLR » [Node 006] querying the CC version for Multilevel Switch... 13:52:22.434 DRIVER Send queue: (2 messages) · [REQ] SendData (VersionCCCommandClassGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.437 SERIAL » 0x010a0013060386132625abde (12 bytes) 13:52:22.437 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 171 └─[VersionCCCommandClassGet] CC: Multilevel Switch 13:52:22.437 DRIVER send thread state: sending.execute 13:52:22.438 SERIAL « [ACK] (0x06) 13:52:22.439 DRIVER send thread state: sending.execute 13:52:22.445 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.445 SERIAL » [ACK] (0x06) 13:52:22.445 DRIVER « [RES] [SendData] was sent: true 13:52:22.446 DRIVER send thread state: sending.execute 13:52:22.461 SERIAL « 0x01070013ab00000242 (9 bytes) 13:52:22.461 SERIAL » [ACK] (0x06) 13:52:22.462 DRIVER « [REQ] [SendData] callback id: 171 transmit status: OK 13:52:22.464 DRIVER send thread state: sending.execute 13:52:22.465 DRIVER send thread state: sending.waitForUpdate 13:52:22.473 SERIAL « 0x010a00040006048614260344 (12 bytes) 13:52:22.473 SERIAL » [ACK] (0x06) 13:52:22.473 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[VersionCCCommandClassReport] CC: Multilevel Switch version: 3 13:52:22.474 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.475 DRIVER send thread state: idle 13:52:22.475 CNTRLR [Node 006] supports CC Multilevel Switch (0x26) in version 3 13:52:22.475 CNTRLR [Node 006] [+] [Version] interviewComplete: true [Endpoint 0] [internal] 13:52:22.475 CNTRLR [Node 006] trying to load device config 13:52:22.500 CNTRLR [Node 006] device config loaded 13:52:22.508 CNTRLR [Node 006] ZWavePlusCC: doing a complete interview... 13:52:22.508 CNTRLR » [Node 006] querying Z-Wave+ information... 13:52:22.509 DRIVER Send queue: (2 messages) · [REQ] SendData (ZWavePlusCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.511 SERIAL » 0x0109001306025e0125ac37 (11 bytes) 13:52:22.512 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 172 └─[ZWavePlusCCGet] 13:52:22.512 DRIVER send thread state: sending.execute 13:52:22.513 SERIAL « [ACK] (0x06) 13:52:22.513 DRIVER send thread state: sending.execute 13:52:22.519 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.519 SERIAL » [ACK] (0x06) 13:52:22.519 DRIVER « [RES] [SendData] was sent: true 13:52:22.520 DRIVER send thread state: sending.execute 13:52:22.535 SERIAL « 0x01070013ac00000344 (9 bytes) 13:52:22.536 SERIAL » [ACK] (0x06) 13:52:22.536 DRIVER « [REQ] [SendData] callback id: 172 transmit status: OK 13:52:22.536 DRIVER send thread state: sending.execute 13:52:22.537 DRIVER send thread state: sending.waitForUpdate 13:52:22.547 SERIAL « 0x010f00040006095e0201050007000700a3 (17 bytes) 13:52:22.548 CNTRLR [Node 006] [+] [Z-Wave Plus Info] zwavePlusVersion: 1 [Endpoint 0] 13:52:22.548 CNTRLR [Node 006] [+] [Z-Wave Plus Info] nodeType: 0 [Endpoint 0] 13:52:22.548 CNTRLR [Node 006] [+] [Z-Wave Plus Info] roleType: 5 [Endpoint 0] 13:52:22.548 CNTRLR [Node 006] [+] [Z-Wave Plus Info] installerIcon: 1792 [Endpoint 0] 13:52:22.548 CNTRLR [Node 006] [+] [Z-Wave Plus Info] userIcon: 1792 [Endpoint 0] 13:52:22.548 SERIAL » [ACK] (0x06) 13:52:22.549 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ZWavePlusCCReport] version: 1 node type: Node role type: AlwaysOnSlave icon (mgmt.): 0x0700 icon (user): 0x0700 13:52:22.549 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.549 DRIVER send thread state: idle 13:52:22.549 CNTRLR « [Node 006] received response for Z-Wave+ information: Z-Wave+ version: 1 role type: AlwaysOnSlave node type: Node installer icon: 0x0700 user icon: 0x0700 13:52:22.550 CNTRLR [Node 006] [+] [Z-Wave Plus Info] interviewComplete: t [Endpoint 0] [internal] rue 13:52:22.550 CNTRLR » [Node 006] querying device endpoint information... 13:52:22.550 DRIVER Send queue: (2 messages) · [REQ] SendData (MultiChannelCCEndPointGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.551 SERIAL » 0x010900130602600725ad0e (11 bytes) 13:52:22.551 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 173 └─[MultiChannelCCEndPointGet] 13:52:22.551 DRIVER send thread state: sending.execute 13:52:22.553 SERIAL « [ACK] (0x06) 13:52:22.553 DRIVER send thread state: sending.execute 13:52:22.559 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.559 SERIAL » [ACK] (0x06) 13:52:22.559 DRIVER « [RES] [SendData] was sent: true 13:52:22.559 DRIVER send thread state: sending.execute 13:52:22.575 SERIAL « 0x01070013ad00000244 (9 bytes) 13:52:22.575 SERIAL » [ACK] (0x06) 13:52:22.575 DRIVER « [REQ] [SendData] callback id: 173 transmit status: OK 13:52:22.577 DRIVER send thread state: sending.execute 13:52:22.577 DRIVER send thread state: sending.waitForUpdate 13:52:22.587 SERIAL « 0x010b00040006056008400200d9 (13 bytes) 13:52:22.588 CNTRLR [Node 006] [+] [Multi Channel] countIsDynamic: false [Endpoint 0] [internal] 13:52:22.588 CNTRLR [Node 006] [+] [Multi Channel] identicalCapabilities: [Endpoint 0] [internal] true 13:52:22.588 CNTRLR [Node 006] [+] [Multi Channel] individualCount: 2 [Endpoint 0] [internal] 13:52:22.589 CNTRLR [Node 006] [+] [Multi Channel] aggregatedCount: 0 [Endpoint 0] [internal] 13:52:22.589 SERIAL » [ACK] (0x06) 13:52:22.589 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointReport] endpoint count (individual): 2 count is dynamic: false identical capabilities: true endpoint count (aggregated): 0 13:52:22.590 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.591 DRIVER send thread state: idle 13:52:22.591 CNTRLR « [Node 006] received response for device endpoints: endpoint count (individual): 2 count is dynamic: false identical capabilities: true endpoint count (aggregated): 0 13:52:22.591 CNTRLR » [Node 006] querying all endpoints... 13:52:22.593 DRIVER Send queue: (2 messages) · [REQ] SendData (MultiChannelCCEndPointFind) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.596 SERIAL » 0x010b00130604600bffff25ae05 (13 bytes) 13:52:22.597 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 174 └─[MultiChannelCCEndPointFind] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) 13:52:22.597 DRIVER send thread state: sending.execute 13:52:22.598 SERIAL « [ACK] (0x06) 13:52:22.599 DRIVER send thread state: sending.execute 13:52:22.605 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.605 SERIAL » [ACK] (0x06) 13:52:22.606 DRIVER « [RES] [SendData] was sent: true 13:52:22.607 DRIVER send thread state: sending.execute 13:52:22.621 SERIAL « 0x01070013ae00000247 (9 bytes) 13:52:22.621 SERIAL » [ACK] (0x06) 13:52:22.622 DRIVER « [REQ] [SendData] callback id: 174 transmit status: OK 13:52:22.623 DRIVER send thread state: sending.execute 13:52:22.624 DRIVER send thread state: sending.waitForUpdate 13:52:22.633 SERIAL « 0x010d0004000607600c00ffff010298 (15 bytes) 13:52:22.634 SERIAL » [ACK] (0x06) 13:52:22.636 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MultiChannelCCEndPointFindReport] generic device class: Non-Interoperable specific device class: UNKNOWN (0xff) found endpoints: 1, 2 # of reports to follow: 0 13:52:22.636 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.637 DRIVER send thread state: idle 13:52:22.637 CNTRLR « [Node 006] received endpoints: 1, 2 13:52:22.637 CNTRLR » [Node 006] querying capabilities for endpoint #1... 13:52:22.641 DRIVER Send queue: (2 messages) · [REQ] SendData (MultiChannelCCCapabilityGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.644 SERIAL » 0x010a0013060360090125af01 (12 bytes) 13:52:22.644 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 175 └─[MultiChannelCCCapabilityGet] endpoint: 1 13:52:22.645 DRIVER send thread state: sending.execute 13:52:22.646 SERIAL « [ACK] (0x06) 13:52:22.647 DRIVER send thread state: sending.execute 13:52:22.653 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.653 SERIAL » [ACK] (0x06) 13:52:22.653 DRIVER « [RES] [SendData] was sent: true 13:52:22.654 DRIVER send thread state: sending.execute 13:52:22.669 SERIAL « 0x01070013af00000246 (9 bytes) 13:52:22.669 SERIAL » [ACK] (0x06) 13:52:22.669 DRIVER « [REQ] [SendData] callback id: 175 transmit status: OK 13:52:22.671 DRIVER send thread state: sending.execute 13:52:22.671 DRIVER send thread state: sending.waitForUpdate 13:52:22.682 SERIAL « 0x0114000400060e600a0110015e862585598e32ef26c9 (22 bytes) 13:52:22.683 CNTRLR [Node 006] [+] [Multi Channel] commandClasses: 94,134, [Endpoint 1] [internal] 37,133,89,142,50 13:52:22.683 SERIAL » [ACK] (0x06) 13:52:22.684 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MultiChannelCCCapabilityReport] endpoint index: 1 generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Z-Wave Plus Info · Version · Binary Switch · Association · Association Group Information · Multi Channel Association · Meter 13:52:22.685 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.685 DRIVER send thread state: idle 13:52:22.686 CNTRLR « [Node 006] received response for endpoint capabilities (#1): generic device class: Binary Switch specific device class: Binary Power Switch is dynamic end point: false supported CCs: · Z-Wave Plus Info · Version · Binary Switch · Association · Association Group Information · Multi Channel Association · Meter 13:52:22.686 CNTRLR [Node 006] all endpoints idendical, skipping capability query for endpoint #2. .. 13:52:22.686 CNTRLR [Node 006] [+] [Multi Channel] commandClasses: 94,134, [Endpoint 2] [internal] 37,133,89,142,50 13:52:22.686 CNTRLR [Node 006] [+] [Multi Channel] interviewComplete: true [Endpoint 0] [internal] 13:52:22.705 CNTRLR [Node 006] ZWavePlusCC: doing a complete interview... [Endpoint 1] 13:52:22.705 CNTRLR » [Node 006] querying Z-Wave+ information... [Endpoint 1] 13:52:22.707 DRIVER Send queue: (2 messages) · [REQ] SendData (MultiChannelCCCommandEncapsulation) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.709 SERIAL » 0x010d00130606600d00015e0125b047 (15 bytes) 13:52:22.710 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 176 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[ZWavePlusCCGet] 13:52:22.710 DRIVER send thread state: sending.execute 13:52:22.711 SERIAL « [ACK] (0x06) 13:52:22.712 DRIVER send thread state: sending.execute 13:52:22.718 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.718 SERIAL » [ACK] (0x06) 13:52:22.719 DRIVER « [RES] [SendData] was sent: true 13:52:22.720 DRIVER send thread state: sending.execute 13:52:22.734 SERIAL « 0x01070013b000000259 (9 bytes) 13:52:22.735 SERIAL » [ACK] (0x06) 13:52:22.735 DRIVER « [REQ] [SendData] callback id: 176 transmit status: OK 13:52:22.737 DRIVER send thread state: sending.execute 13:52:22.737 DRIVER send thread state: sending.waitForUpdate 13:52:22.747 SERIAL « 0x0113000400060d600d01005e0201050007000700d7 (21 bytes) 13:52:22.748 CNTRLR [Node 006] [+] [Z-Wave Plus Info] zwavePlusVersion: 1 [Endpoint 1] 13:52:22.749 CNTRLR [Node 006] [+] [Z-Wave Plus Info] nodeType: 0 [Endpoint 1] 13:52:22.751 CNTRLR [Node 006] [+] [Z-Wave Plus Info] roleType: 5 [Endpoint 1] 13:52:22.752 CNTRLR [Node 006] [+] [Z-Wave Plus Info] installerIcon: 1792 [Endpoint 1] 13:52:22.752 CNTRLR [Node 006] [+] [Z-Wave Plus Info] userIcon: 1792 [Endpoint 1] 13:52:22.752 SERIAL » [ACK] (0x06) 13:52:22.753 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[ZWavePlusCCReport] version: 1 node type: Node role type: AlwaysOnSlave icon (mgmt.): 0x0700 icon (user): 0x0700 13:52:22.754 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.755 DRIVER send thread state: idle 13:52:22.755 CNTRLR « [Node 006] received response for Z-Wave+ information: [Endpoint 1] Z-Wave+ version: 1 role type: AlwaysOnSlave node type: Node installer icon: 0x0700 user icon: 0x0700 13:52:22.755 CNTRLR [Node 006] [+] [Z-Wave Plus Info] interviewComplete: t [Endpoint 1] [internal] rue 13:52:22.756 CNTRLR [Node 006] BinarySwitchCC: doing a complete interview... [Endpoint 1] 13:52:22.756 CNTRLR » [Node 006] querying Binary Switch state... [Endpoint 1] 13:52:22.758 DRIVER Send queue: (2 messages) · [REQ] SendData (MultiChannelCCCommandEncapsulation) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.760 SERIAL » 0x010d00130606600d0001250225b13e (15 bytes) 13:52:22.760 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 177 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[BinarySwitchCCGet] 13:52:22.760 DRIVER send thread state: sending.execute 13:52:22.764 SERIAL « [ACK] (0x06) 13:52:22.765 DRIVER send thread state: sending.execute 13:52:22.769 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.769 SERIAL » [ACK] (0x06) 13:52:22.770 DRIVER « [RES] [SendData] was sent: true 13:52:22.771 DRIVER send thread state: sending.execute 13:52:22.785 SERIAL « 0x01070013b100000258 (9 bytes) 13:52:22.785 SERIAL » [ACK] (0x06) 13:52:22.786 DRIVER « [REQ] [SendData] callback id: 177 transmit status: OK 13:52:22.787 DRIVER send thread state: sending.execute 13:52:22.788 DRIVER send thread state: sending.waitForUpdate 13:52:22.797 SERIAL « 0x010d0004000607600d0100250300bd (15 bytes) 13:52:22.798 CNTRLR [Node 006] [+] [Binary Switch] currentValue: false [Endpoint 1] 13:52:22.798 CNTRLR [Node 006] [+] [Binary Switch] targetValue: undefined [Endpoint 1] 13:52:22.799 SERIAL » [ACK] (0x06) 13:52:22.799 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[BinarySwitchCCReport] current value: false 13:52:22.800 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.801 DRIVER send thread state: idle 13:52:22.801 CNTRLR « [Node 006] received Binary Switch state: [Endpoint 1] current value: false 13:52:22.801 CNTRLR [Node 006] [+] [Binary Switch] interviewComplete: true [Endpoint 1] [internal] 13:52:22.802 CNTRLR [Node 006] MeterCC: doing a complete interview... [Endpoint 1] 13:52:22.802 CNTRLR » [Node 006] querying default meter value... [Endpoint 1] 13:52:22.803 DRIVER Send queue: (2 messages) · [REQ] SendData (MultiChannelCCCommandEncapsulation) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.806 SERIAL » 0x010d00130606600d0001320125b229 (15 bytes) 13:52:22.806 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 178 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 1 └─[MeterCCGet] 13:52:22.806 DRIVER send thread state: sending.execute 13:52:22.808 SERIAL « [ACK] (0x06) 13:52:22.809 DRIVER send thread state: sending.execute 13:52:22.815 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.816 SERIAL » [ACK] (0x06) 13:52:22.816 DRIVER « [RES] [SendData] was sent: true 13:52:22.817 DRIVER send thread state: sending.execute 13:52:22.831 SERIAL « 0x01070013b20000025b (9 bytes) 13:52:22.831 SERIAL » [ACK] (0x06) 13:52:22.832 DRIVER « [REQ] [SendData] callback id: 178 transmit status: OK 13:52:22.833 DRIVER send thread state: sending.execute 13:52:22.834 DRIVER send thread state: sending.waitForUpdate 13:52:22.844 SERIAL « 0x0112000400060c600d01003202014400000000fa (20 bytes) 13:52:22.845 CNTRLR [Node 006] [Meter] value[65536]: metadata updated [Endpoint 1] 13:52:22.845 CNTRLR [Node 006] [+] [Meter] value[65536]: 0 [Endpoint 1] 13:52:22.846 CNTRLR [Node 006] [+] [Meter] deltaTime[65536]: 0 [Endpoint 1] 13:52:22.846 SERIAL » [ACK] (0x06) 13:52:22.847 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 0 └─[MeterCCReport] type: Electric scale: kWh rate type: Unspecified value: 0 time delta: 0 seconds 13:52:22.848 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.848 DRIVER send thread state: idle 13:52:22.849 CNTRLR [Node 006] [+] [Meter] interviewComplete: true [Endpoint 1] [internal] 13:52:22.850 CNTRLR [Node 006] ZWavePlusCC: doing a complete interview... [Endpoint 2] 13:52:22.850 CNTRLR » [Node 006] querying Z-Wave+ information... [Endpoint 2] 13:52:22.851 DRIVER Send queue: (2 messages) · [REQ] SendData (MultiChannelCCCommandEncapsulation) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.853 SERIAL » 0x010d00130606600d00025e0125b347 (15 bytes) 13:52:22.854 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 179 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[ZWavePlusCCGet] 13:52:22.854 DRIVER send thread state: sending.execute 13:52:22.870 SERIAL « [ACK] (0x06) 13:52:22.871 DRIVER send thread state: sending.execute 13:52:22.871 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.871 SERIAL » [ACK] (0x06) 13:52:22.872 DRIVER « [RES] [SendData] was sent: true 13:52:22.872 DRIVER send thread state: sending.execute 13:52:22.878 SERIAL « 0x01070013b30000025a (9 bytes) 13:52:22.879 SERIAL » [ACK] (0x06) 13:52:22.879 DRIVER « [REQ] [SendData] callback id: 179 transmit status: OK 13:52:22.879 DRIVER send thread state: sending.execute 13:52:22.880 DRIVER send thread state: sending.waitForUpdate 13:52:22.891 SERIAL « 0x0113000400060d600d02005e0201050007000700d4 (21 bytes) 13:52:22.892 CNTRLR [Node 006] [+] [Z-Wave Plus Info] zwavePlusVersion: 1 [Endpoint 2] 13:52:22.892 CNTRLR [Node 006] [+] [Z-Wave Plus Info] nodeType: 0 [Endpoint 2] 13:52:22.892 CNTRLR [Node 006] [+] [Z-Wave Plus Info] roleType: 5 [Endpoint 2] 13:52:22.892 CNTRLR [Node 006] [+] [Z-Wave Plus Info] installerIcon: 1792 [Endpoint 2] 13:52:22.892 CNTRLR [Node 006] [+] [Z-Wave Plus Info] userIcon: 1792 [Endpoint 2] 13:52:22.892 SERIAL » [ACK] (0x06) 13:52:22.893 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[ZWavePlusCCReport] version: 1 node type: Node role type: AlwaysOnSlave icon (mgmt.): 0x0700 icon (user): 0x0700 13:52:22.893 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.893 DRIVER send thread state: idle 13:52:22.893 CNTRLR « [Node 006] received response for Z-Wave+ information: [Endpoint 2] Z-Wave+ version: 1 role type: AlwaysOnSlave node type: Node installer icon: 0x0700 user icon: 0x0700 13:52:22.894 CNTRLR [Node 006] [+] [Z-Wave Plus Info] interviewComplete: t [Endpoint 2] [internal] rue 13:52:22.894 CNTRLR [Node 006] BinarySwitchCC: doing a complete interview... [Endpoint 2] 13:52:22.894 CNTRLR » [Node 006] querying Binary Switch state... [Endpoint 2] 13:52:22.894 DRIVER Send queue: (2 messages) · [REQ] SendData (MultiChannelCCCommandEncapsulation) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.895 SERIAL » 0x010d00130606600d0002250225b438 (15 bytes) 13:52:22.896 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 180 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[BinarySwitchCCGet] 13:52:22.896 DRIVER send thread state: sending.execute 13:52:22.897 SERIAL « [ACK] (0x06) 13:52:22.898 DRIVER send thread state: sending.execute 13:52:22.904 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.904 SERIAL » [ACK] (0x06) 13:52:22.904 DRIVER « [RES] [SendData] was sent: true 13:52:22.904 DRIVER send thread state: sending.execute 13:52:22.920 SERIAL « 0x01070013b40000025d (9 bytes) 13:52:22.921 SERIAL » [ACK] (0x06) 13:52:22.921 DRIVER « [REQ] [SendData] callback id: 180 transmit status: OK 13:52:22.922 DRIVER send thread state: sending.execute 13:52:22.922 DRIVER send thread state: sending.waitForUpdate 13:52:22.932 SERIAL « 0x010d0004000607600d0200250300be (15 bytes) 13:52:22.933 CNTRLR [Node 006] [+] [Binary Switch] currentValue: false [Endpoint 2] 13:52:22.933 CNTRLR [Node 006] [+] [Binary Switch] targetValue: undefined [Endpoint 2] 13:52:22.934 SERIAL » [ACK] (0x06) 13:52:22.934 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[BinarySwitchCCReport] current value: false 13:52:22.935 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.936 DRIVER send thread state: idle 13:52:22.936 CNTRLR « [Node 006] received Binary Switch state: [Endpoint 2] current value: false 13:52:22.936 CNTRLR [Node 006] [+] [Binary Switch] interviewComplete: true [Endpoint 2] [internal] 13:52:22.937 CNTRLR [Node 006] MeterCC: doing a complete interview... [Endpoint 2] 13:52:22.937 CNTRLR » [Node 006] querying default meter value... [Endpoint 2] 13:52:22.938 DRIVER Send queue: (2 messages) · [REQ] SendData (MultiChannelCCCommandEncapsulation) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.943 SERIAL » 0x010d00130606600d0002320125b52d (15 bytes) 13:52:22.944 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 181 └─[MultiChannelCCCommandEncapsulation] │ source: 0 │ destination: 2 └─[MeterCCGet] 13:52:22.944 DRIVER send thread state: sending.execute 13:52:22.965 SERIAL « [ACK] (0x06) 13:52:22.968 DRIVER send thread state: sending.execute 13:52:22.968 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.969 SERIAL » [ACK] (0x06) 13:52:22.971 DRIVER « [RES] [SendData] was sent: true 13:52:22.972 DRIVER send thread state: sending.execute 13:52:22.972 SERIAL « 0x01070013b50000025c (9 bytes) 13:52:22.973 SERIAL » [ACK] (0x06) 13:52:22.976 DRIVER « [REQ] [SendData] callback id: 181 transmit status: OK 13:52:22.977 DRIVER send thread state: sending.execute 13:52:22.977 DRIVER send thread state: sending.waitForUpdate 13:52:22.983 SERIAL « 0x0112000400060c600d02003202014400000d20d4 (20 bytes) 13:52:22.983 CNTRLR [Node 006] [Meter] value[65536]: metadata updated [Endpoint 2] 13:52:22.983 CNTRLR [Node 006] [+] [Meter] value[65536]: 33.6 [Endpoint 2] 13:52:22.983 CNTRLR [Node 006] [+] [Meter] deltaTime[65536]: 0 [Endpoint 2] 13:52:22.984 SERIAL » [ACK] (0x06) 13:52:22.984 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 2 │ destination: 0 └─[MeterCCReport] type: Electric scale: kWh rate type: Unspecified value: 33.6 time delta: 0 seconds 13:52:22.985 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.985 DRIVER send thread state: idle 13:52:22.985 CNTRLR [Node 006] [+] [Meter] interviewComplete: true [Endpoint 2] [internal] 13:52:22.985 CNTRLR [Node 006] BinarySwitchCC: doing a complete interview... 13:52:22.985 CNTRLR » [Node 006] querying Binary Switch state... 13:52:22.989 DRIVER Send queue: (2 messages) · [REQ] SendData (BinarySwitchCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:22.990 SERIAL » 0x010900130602250225b655 (11 bytes) 13:52:22.990 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 182 └─[BinarySwitchCCGet] 13:52:22.990 DRIVER send thread state: sending.execute 13:52:22.991 SERIAL « [ACK] (0x06) 13:52:22.992 DRIVER send thread state: sending.execute 13:52:22.997 SERIAL « 0x0104011301e8 (6 bytes) 13:52:22.998 SERIAL » [ACK] (0x06) 13:52:22.998 DRIVER « [RES] [SendData] was sent: true 13:52:22.998 DRIVER send thread state: sending.execute 13:52:23.013 SERIAL « 0x01070013b60000025f (9 bytes) 13:52:23.013 SERIAL » [ACK] (0x06) 13:52:23.013 DRIVER « [REQ] [SendData] callback id: 182 transmit status: OK 13:52:23.014 DRIVER send thread state: sending.execute 13:52:23.014 DRIVER send thread state: sending.waitForUpdate 13:52:23.025 SERIAL « 0x01090004000603250300d1 (11 bytes) 13:52:23.025 CNTRLR [Node 006] [+] [Binary Switch] currentValue: false [Endpoint 0] 13:52:23.025 CNTRLR [Node 006] [+] [Binary Switch] targetValue: undefined [Endpoint 0] 13:52:23.025 SERIAL » [ACK] (0x06) 13:52:23.025 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[BinarySwitchCCReport] current value: false 13:52:23.026 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.026 DRIVER send thread state: idle 13:52:23.026 CNTRLR « [Node 006] received Binary Switch state: current value: false 13:52:23.026 CNTRLR [Node 006] [+] [Binary Switch] interviewComplete: true [Endpoint 0] [internal] 13:52:23.032 CNTRLR [Node 006] ConfigurationCC: Loading configuration parameters from device confi g 13:52:23.034 CNTRLR [Node 006] [+] [Configuration] isParamInformationFromConfig: false [internal] 13:52:23.034 CNTRLR [Node 006] [Configuration] 9: metadata updated 13:52:23.035 CNTRLR [Node 006] [Configuration] 10: metadata updated 13:52:23.035 CNTRLR [Node 006] [Configuration] 11: metadata updated 13:52:23.035 CNTRLR [Node 006] [Configuration] 12: metadata updated 13:52:23.036 CNTRLR [Node 006] [Configuration] 13: metadata updated 13:52:23.036 CNTRLR [Node 006] [Configuration] 15: metadata updated 13:52:23.036 CNTRLR [Node 006] [Configuration] 16: metadata updated 13:52:23.036 CNTRLR [Node 006] [Configuration] 17: metadata updated 13:52:23.037 CNTRLR [Node 006] [Configuration] 18: metadata updated 13:52:23.037 CNTRLR [Node 006] [Configuration] 20: metadata updated 13:52:23.037 CNTRLR [Node 006] [Configuration] 21: metadata updated 13:52:23.037 CNTRLR [Node 006] [Configuration] 27: metadata updated 13:52:23.038 CNTRLR [Node 006] [Configuration] 28: metadata updated 13:52:23.038 CNTRLR [Node 006] [Configuration] 29: metadata updated 13:52:23.038 CNTRLR [Node 006] [Configuration] 30: metadata updated 13:52:23.038 CNTRLR [Node 006] [Configuration] 31: metadata updated 13:52:23.038 CNTRLR [Node 006] [Configuration] 32: metadata updated 13:52:23.039 CNTRLR [Node 006] [Configuration] 33: metadata updated 13:52:23.039 CNTRLR [Node 006] [Configuration] 35: metadata updated 13:52:23.039 CNTRLR [Node 006] [Configuration] 36: metadata updated 13:52:23.039 CNTRLR [Node 006] [Configuration] 37: metadata updated 13:52:23.040 CNTRLR [Node 006] [Configuration] 38: metadata updated 13:52:23.040 CNTRLR [Node 006] [Configuration] 40: metadata updated 13:52:23.040 CNTRLR [Node 006] [Configuration] 41: metadata updated 13:52:23.040 CNTRLR [Node 006] [Configuration] 42: metadata updated 13:52:23.041 CNTRLR [Node 006] [Configuration] 43: metadata updated 13:52:23.041 CNTRLR [Node 006] [Configuration] 44: metadata updated 13:52:23.041 CNTRLR [Node 006] [Configuration] 50: metadata updated 13:52:23.041 CNTRLR [Node 006] [Configuration] 51: metadata updated 13:52:23.042 CNTRLR [Node 006] [Configuration] 53: metadata updated 13:52:23.042 CNTRLR [Node 006] [Configuration] 54: metadata updated 13:52:23.042 CNTRLR [Node 006] [Configuration] 55: metadata updated 13:52:23.042 CNTRLR [Node 006] [Configuration] 57: metadata updated 13:52:23.043 CNTRLR [Node 006] [Configuration] 58: metadata updated 13:52:23.043 CNTRLR [Node 006] [Configuration] 59: metadata updated 13:52:23.043 CNTRLR [Node 006] [Configuration] 60: metadata updated 13:52:23.043 CNTRLR [Node 006] [~] [Configuration] isParamInformationFromConfig: false [internal] => true 13:52:23.044 CNTRLR » [Node 006] querying parameter #9 value... 13:52:23.044 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.045 SERIAL » 0x010a0013060370050925b70d (12 bytes) 13:52:23.046 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 183 └─[ConfigurationCCGet] parameter #: 9 13:52:23.046 DRIVER send thread state: sending.execute 13:52:23.051 SERIAL « [ACK] (0x06) 13:52:23.052 DRIVER send thread state: sending.execute 13:52:23.060 SERIAL « 0x0104011301e8 (6 bytes) 13:52:23.060 SERIAL » [ACK] (0x06) 13:52:23.061 DRIVER « [RES] [SendData] was sent: true 13:52:23.061 DRIVER send thread state: sending.execute 13:52:23.070 SERIAL « 0x01070013b70000025e (9 bytes) 13:52:23.070 SERIAL » [ACK] (0x06) 13:52:23.070 DRIVER « [REQ] [SendData] callback id: 183 transmit status: OK 13:52:23.071 DRIVER send thread state: sending.execute 13:52:23.071 DRIVER send thread state: sending.waitForUpdate 13:52:23.081 SERIAL « 0x010b000400060570060901018c (13 bytes) 13:52:23.084 CNTRLR [Node 006] [+] [Configuration] 9: 1 13:52:23.084 SERIAL » [ACK] (0x06) 13:52:23.084 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 9 value size: 1 value: 1 13:52:23.085 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.085 DRIVER send thread state: idle 13:52:23.085 CNTRLR « [Node 006] parameter #9 has value: 1 13:52:23.085 CNTRLR » [Node 006] querying parameter #10 value... 13:52:23.086 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.087 SERIAL » 0x010a0013060370050a25b801 (12 bytes) 13:52:23.087 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 184 └─[ConfigurationCCGet] parameter #: 10 13:52:23.087 DRIVER send thread state: sending.execute 13:52:23.088 SERIAL « [ACK] (0x06) 13:52:23.089 DRIVER send thread state: sending.execute 13:52:23.095 SERIAL « 0x0104011301e8 (6 bytes) 13:52:23.095 SERIAL » [ACK] (0x06) 13:52:23.095 DRIVER « [RES] [SendData] was sent: true 13:52:23.095 DRIVER send thread state: sending.execute 13:52:23.111 SERIAL « 0x01070013b800000251 (9 bytes) 13:52:23.112 SERIAL » [ACK] (0x06) 13:52:23.112 DRIVER « [REQ] [SendData] callback id: 184 transmit status: OK 13:52:23.112 DRIVER send thread state: sending.execute 13:52:23.113 DRIVER send thread state: sending.waitForUpdate 13:52:23.123 SERIAL « 0x010b000400060570060a01008e (13 bytes) 13:52:23.125 CNTRLR [Node 006] [+] [Configuration] 10: 0 13:52:23.126 SERIAL » [ACK] (0x06) 13:52:23.126 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 10 value size: 1 value: 0 13:52:23.126 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.126 DRIVER send thread state: idle 13:52:23.126 CNTRLR « [Node 006] parameter #10 has value: 0 13:52:23.126 CNTRLR » [Node 006] querying parameter #11 value... 13:52:23.127 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.128 SERIAL » 0x010a0013060370050b25b901 (12 bytes) 13:52:23.128 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 185 └─[ConfigurationCCGet] parameter #: 11 13:52:23.128 DRIVER send thread state: sending.execute 13:52:23.131 SERIAL « [ACK] (0x06) 13:52:23.132 DRIVER send thread state: sending.execute 13:52:23.136 SERIAL « 0x0104011301e8 (6 bytes) 13:52:23.136 SERIAL » [ACK] (0x06) 13:52:23.136 DRIVER « [RES] [SendData] was sent: true 13:52:23.136 DRIVER send thread state: sending.execute 13:52:23.152 SERIAL « 0x01070013b900000250 (9 bytes) 13:52:23.152 SERIAL » [ACK] (0x06) 13:52:23.152 DRIVER « [REQ] [SendData] callback id: 185 transmit status: OK 13:52:23.153 DRIVER send thread state: sending.execute 13:52:23.153 DRIVER send thread state: sending.waitForUpdate 13:52:23.163 SERIAL « 0x010b000400060570060b01008f (13 bytes) 13:52:23.166 CNTRLR [Node 006] [+] [Configuration] 11: 0 13:52:23.167 SERIAL » [ACK] (0x06) 13:52:23.167 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 11 value size: 1 value: 0 13:52:23.167 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.168 DRIVER send thread state: idle 13:52:23.168 CNTRLR « [Node 006] parameter #11 has value: 0 13:52:23.168 CNTRLR » [Node 006] querying parameter #12 value... 13:52:23.169 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.170 SERIAL » 0x010a0013060370050c25ba05 (12 bytes) 13:52:23.170 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 186 └─[ConfigurationCCGet] parameter #: 12 13:52:23.171 DRIVER send thread state: sending.execute 13:52:23.172 SERIAL « [ACK] (0x06) 13:52:23.173 DRIVER send thread state: sending.execute 13:52:23.179 SERIAL « 0x0104011301e8 (6 bytes) 13:52:23.179 SERIAL » [ACK] (0x06) 13:52:23.179 DRIVER « [RES] [SendData] was sent: true 13:52:23.180 DRIVER send thread state: sending.execute 13:52:23.195 SERIAL « 0x01070013ba00000253 (9 bytes) 13:52:23.195 SERIAL » [ACK] (0x06) 13:52:23.195 DRIVER « [REQ] [SendData] callback id: 186 transmit status: OK 13:52:23.197 DRIVER send thread state: sending.execute 13:52:23.197 DRIVER send thread state: sending.waitForUpdate 13:52:23.213 SERIAL « 0x010c000400060670060c020032bd (14 bytes) 13:52:23.218 CNTRLR [Node 006] [+] [Configuration] 12: 50 13:52:23.219 SERIAL » [ACK] (0x06) 13:52:23.220 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 12 value size: 2 value: 50 13:52:23.222 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.222 DRIVER send thread state: idle 13:52:23.222 CNTRLR « [Node 006] parameter #12 has value: 50 13:52:23.222 CNTRLR » [Node 006] querying parameter #13 value... 13:52:23.224 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.226 SERIAL » 0x010a0013060370050d25bb05 (12 bytes) 13:52:23.226 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 187 └─[ConfigurationCCGet] parameter #: 13 13:52:23.227 DRIVER send thread state: sending.execute 13:52:23.228 SERIAL « [ACK] (0x06) 13:52:23.228 DRIVER send thread state: sending.execute 13:52:23.234 SERIAL « 0x0104011301e8 (6 bytes) 13:52:23.234 SERIAL » [ACK] (0x06) 13:52:23.235 DRIVER « [RES] [SendData] was sent: true 13:52:23.235 DRIVER send thread state: sending.execute 13:52:23.250 SERIAL « 0x01070013bb00000252 (9 bytes) 13:52:23.251 SERIAL » [ACK] (0x06) 13:52:23.251 DRIVER « [REQ] [SendData] callback id: 187 transmit status: OK 13:52:23.252 DRIVER send thread state: sending.execute 13:52:23.252 DRIVER send thread state: sending.waitForUpdate 13:52:23.262 SERIAL « 0x010c000400060670060d0200058b (14 bytes) 13:52:23.264 CNTRLR [Node 006] [+] [Configuration] 13: 5 13:52:23.265 SERIAL » [ACK] (0x06) 13:52:23.265 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 13 value size: 2 value: 5 13:52:23.265 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.266 DRIVER send thread state: idle 13:52:23.266 CNTRLR « [Node 006] parameter #13 has value: 5 13:52:23.266 CNTRLR » [Node 006] querying parameter #15 value... 13:52:23.267 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.268 SERIAL » 0x010a0013060370050f25bc00 (12 bytes) 13:52:23.268 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 188 └─[ConfigurationCCGet] parameter #: 15 13:52:23.268 DRIVER send thread state: sending.execute 13:52:23.269 SERIAL « [ACK] (0x06) 13:52:23.270 DRIVER send thread state: sending.execute 13:52:23.276 SERIAL « 0x0104011301e8 (6 bytes) 13:52:23.276 SERIAL » [ACK] (0x06) 13:52:23.276 DRIVER « [RES] [SendData] was sent: true 13:52:23.277 DRIVER send thread state: sending.execute 13:52:23.292 SERIAL « 0x01070013bc00000255 (9 bytes) 13:52:23.292 SERIAL » [ACK] (0x06) 13:52:23.293 DRIVER « [REQ] [SendData] callback id: 188 transmit status: OK 13:52:23.295 DRIVER send thread state: sending.execute 13:52:23.295 DRIVER send thread state: sending.waitForUpdate 13:52:23.304 SERIAL « 0x010b000400060570060f01008b (13 bytes) 13:52:23.309 CNTRLR [Node 006] [+] [Configuration] 15: 0 13:52:23.309 SERIAL » [ACK] (0x06) 13:52:23.310 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 15 value size: 1 value: 0 13:52:23.311 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.311 DRIVER send thread state: idle 13:52:23.312 CNTRLR « [Node 006] parameter #15 has value: 0 13:52:23.312 CNTRLR » [Node 006] querying parameter #16 value... 13:52:23.316 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.318 SERIAL » 0x010a0013060370051025bd1e (12 bytes) 13:52:23.319 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 189 └─[ConfigurationCCGet] parameter #: 16 13:52:23.319 DRIVER send thread state: sending.execute 13:52:23.321 SERIAL « [ACK] (0x06) 13:52:23.322 DRIVER send thread state: sending.execute 13:52:23.328 SERIAL « 0x0104011301e8 (6 bytes) 13:52:23.328 SERIAL » [ACK] (0x06) 13:52:23.329 DRIVER « [RES] [SendData] was sent: true 13:52:23.330 DRIVER send thread state: sending.execute 13:52:23.343 SERIAL « 0x01070013bd00000254 (9 bytes) 13:52:23.343 SERIAL » [ACK] (0x06) 13:52:23.344 DRIVER « [REQ] [SendData] callback id: 189 transmit status: OK 13:52:23.345 DRIVER send thread state: sending.execute 13:52:23.346 DRIVER send thread state: sending.waitForUpdate 13:52:23.355 SERIAL « 0x010b0004000605700610010094 (13 bytes) 13:52:23.360 CNTRLR [Node 006] [+] [Configuration] 16: 0 13:52:23.361 SERIAL » [ACK] (0x06) 13:52:23.361 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 16 value size: 1 value: 0 13:52:23.362 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.362 DRIVER send thread state: idle 13:52:23.362 CNTRLR « [Node 006] parameter #16 has value: 0 13:52:23.363 CNTRLR » [Node 006] querying parameter #17 value... 13:52:23.364 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.366 SERIAL » 0x010a0013060370051125be1c (12 bytes) 13:52:23.367 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 190 └─[ConfigurationCCGet] parameter #: 17 13:52:23.367 DRIVER send thread state: sending.execute 13:52:23.369 SERIAL « [ACK] (0x06) 13:52:23.369 DRIVER send thread state: sending.execute 13:52:23.375 SERIAL « 0x0104011301e8 (6 bytes) 13:52:23.375 SERIAL » [ACK] (0x06) 13:52:23.375 DRIVER « [RES] [SendData] was sent: true 13:52:23.376 DRIVER send thread state: sending.execute 13:52:23.391 SERIAL « 0x01070013be00000257 (9 bytes) 13:52:23.391 SERIAL » [ACK] (0x06) 13:52:23.392 DRIVER « [REQ] [SendData] callback id: 190 transmit status: OK 13:52:23.393 DRIVER send thread state: sending.execute 13:52:23.394 DRIVER send thread state: sending.waitForUpdate 13:52:23.403 SERIAL « 0x010c0004000606700611020032a0 (14 bytes) 13:52:23.407 CNTRLR [Node 006] [+] [Configuration] 17: 50 13:52:23.408 SERIAL » [ACK] (0x06) 13:52:23.409 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 17 value size: 2 value: 50 13:52:23.410 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.410 DRIVER send thread state: idle 13:52:23.410 CNTRLR « [Node 006] parameter #17 has value: 50 13:52:23.410 CNTRLR » [Node 006] querying parameter #18 value... 13:52:23.412 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.414 SERIAL » 0x010a0013060370051225bf1e (12 bytes) 13:52:23.414 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 191 └─[ConfigurationCCGet] parameter #: 18 13:52:23.414 DRIVER send thread state: sending.execute 13:52:23.416 SERIAL « [ACK] (0x06) 13:52:23.417 DRIVER send thread state: sending.execute 13:52:23.422 SERIAL « 0x0104011301e8 (6 bytes) 13:52:23.423 SERIAL » [ACK] (0x06) 13:52:23.423 DRIVER « [RES] [SendData] was sent: true 13:52:23.425 DRIVER send thread state: sending.execute 13:52:23.438 SERIAL « 0x01070013bf00000256 (9 bytes) 13:52:23.438 SERIAL » [ACK] (0x06) 13:52:23.439 DRIVER « [REQ] [SendData] callback id: 191 transmit status: OK 13:52:23.440 DRIVER send thread state: sending.execute 13:52:23.440 DRIVER send thread state: sending.waitForUpdate 13:52:23.450 SERIAL « 0x010c000400060670061202000594 (14 bytes) 13:52:23.453 CNTRLR [Node 006] [+] [Configuration] 18: 5 13:52:23.454 SERIAL » [ACK] (0x06) 13:52:23.454 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 18 value size: 2 value: 5 13:52:23.455 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.455 DRIVER send thread state: idle 13:52:23.455 CNTRLR « [Node 006] parameter #18 has value: 5 13:52:23.455 CNTRLR » [Node 006] querying parameter #20 value... 13:52:23.456 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.459 SERIAL » 0x010a0013060370051425c067 (12 bytes) 13:52:23.459 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 192 └─[ConfigurationCCGet] parameter #: 20 13:52:23.460 DRIVER send thread state: sending.execute 13:52:23.461 SERIAL « [ACK] (0x06) 13:52:23.462 DRIVER send thread state: sending.execute 13:52:23.467 SERIAL « 0x0104011301e8 (6 bytes) 13:52:23.468 SERIAL » [ACK] (0x06) 13:52:23.468 DRIVER « [RES] [SendData] was sent: true 13:52:23.469 DRIVER send thread state: sending.execute 13:52:23.484 SERIAL « 0x01070013c000000229 (9 bytes) 13:52:23.484 SERIAL » [ACK] (0x06) 13:52:23.485 DRIVER « [REQ] [SendData] callback id: 192 transmit status: OK 13:52:23.486 DRIVER send thread state: sending.execute 13:52:23.486 DRIVER send thread state: sending.waitForUpdate 13:52:23.495 SERIAL « 0x010b0004000605700614010292 (13 bytes) 13:52:23.500 CNTRLR [Node 006] [+] [Configuration] 20: 2 13:52:23.501 SERIAL » [ACK] (0x06) 13:52:23.501 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 20 value size: 1 value: 2 13:52:23.502 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.502 DRIVER send thread state: idle 13:52:23.503 CNTRLR « [Node 006] parameter #20 has value: 2 13:52:23.503 CNTRLR » [Node 006] querying parameter #21 value... 13:52:23.504 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.506 SERIAL » 0x010a0013060370051525c167 (12 bytes) 13:52:23.507 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 193 └─[ConfigurationCCGet] parameter #: 21 13:52:23.507 DRIVER send thread state: sending.execute 13:52:23.509 SERIAL « [ACK] (0x06) 13:52:23.510 DRIVER send thread state: sending.execute 13:52:23.515 SERIAL « 0x0104011301e8 (6 bytes) 13:52:23.515 SERIAL » [ACK] (0x06) 13:52:23.516 DRIVER « [RES] [SendData] was sent: true 13:52:23.517 DRIVER send thread state: sending.execute 13:52:23.531 SERIAL « 0x01070013c100000228 (9 bytes) 13:52:23.532 SERIAL » [ACK] (0x06) 13:52:23.532 DRIVER « [REQ] [SendData] callback id: 193 transmit status: OK 13:52:23.533 DRIVER send thread state: sending.execute 13:52:23.534 DRIVER send thread state: sending.waitForUpdate 13:52:23.543 SERIAL « 0x010b0004000605700615010091 (13 bytes) 13:52:23.547 CNTRLR [Node 006] [+] [Configuration] 21: 0 13:52:23.548 SERIAL » [ACK] (0x06) 13:52:23.549 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 21 value size: 1 value: 0 13:52:23.549 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.550 DRIVER send thread state: idle 13:52:23.550 CNTRLR « [Node 006] parameter #21 has value: 0 13:52:23.550 CNTRLR » [Node 006] querying parameter #27 value... 13:52:23.551 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.557 SERIAL » 0x010a0013060370051b25c26a (12 bytes) 13:52:23.557 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 194 └─[ConfigurationCCGet] parameter #: 27 13:52:23.557 DRIVER send thread state: sending.execute 13:52:23.559 SERIAL « [ACK] (0x06) 13:52:23.560 DRIVER send thread state: sending.execute 13:52:23.565 SERIAL « 0x0104011301e8 (6 bytes) 13:52:23.566 SERIAL » [ACK] (0x06) 13:52:23.566 DRIVER « [RES] [SendData] was sent: true 13:52:23.567 DRIVER send thread state: sending.execute 13:52:23.581 SERIAL « 0x01070013c20000022b (9 bytes) 13:52:23.582 SERIAL » [ACK] (0x06) 13:52:23.582 DRIVER « [REQ] [SendData] callback id: 194 transmit status: OK 13:52:23.584 DRIVER send thread state: sending.execute 13:52:23.584 DRIVER send thread state: sending.waitForUpdate 13:52:23.593 SERIAL « 0x010b000400060570061b010f90 (13 bytes) 13:52:23.598 CNTRLR [Node 006] [+] [Configuration] 27: 15 13:52:23.599 SERIAL » [ACK] (0x06) 13:52:23.599 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 27 value size: 1 value: 15 13:52:23.600 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.600 DRIVER send thread state: idle 13:52:23.600 CNTRLR « [Node 006] parameter #27 has value: 15 13:52:23.601 CNTRLR » [Node 006] querying parameter #28 value... 13:52:23.602 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.604 SERIAL » 0x010a0013060370051c25c36c (12 bytes) 13:52:23.604 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 195 └─[ConfigurationCCGet] parameter #: 28 13:52:23.605 DRIVER send thread state: sending.execute 13:52:23.607 SERIAL « [ACK] (0x06) 13:52:23.609 DRIVER send thread state: sending.execute 13:52:23.614 SERIAL « 0x0104011301e8 (6 bytes) 13:52:23.614 SERIAL » [ACK] (0x06) 13:52:23.614 DRIVER « [RES] [SendData] was sent: true 13:52:23.615 DRIVER send thread state: sending.execute 13:52:23.629 SERIAL « 0x01070013c30000022a (9 bytes) 13:52:23.629 SERIAL » [ACK] (0x06) 13:52:23.630 DRIVER « [REQ] [SendData] callback id: 195 transmit status: OK 13:52:23.631 DRIVER send thread state: sending.execute 13:52:23.632 DRIVER send thread state: sending.waitForUpdate 13:52:23.641 SERIAL « 0x010b000400060570061c010098 (13 bytes) 13:52:23.645 CNTRLR [Node 006] [+] [Configuration] 28: 0 13:52:23.646 SERIAL » [ACK] (0x06) 13:52:23.647 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 28 value size: 1 value: 0 13:52:23.647 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.648 DRIVER send thread state: idle 13:52:23.648 CNTRLR « [Node 006] parameter #28 has value: 0 13:52:23.648 CNTRLR » [Node 006] querying parameter #29 value... 13:52:23.650 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.652 SERIAL » 0x010a0013060370051d25c46a (12 bytes) 13:52:23.652 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 196 └─[ConfigurationCCGet] parameter #: 29 13:52:23.652 DRIVER send thread state: sending.execute 13:52:23.654 SERIAL « [ACK] (0x06) 13:52:23.655 DRIVER send thread state: sending.execute 13:52:23.660 SERIAL « 0x0104011301e8 (6 bytes) 13:52:23.661 SERIAL » [ACK] (0x06) 13:52:23.661 DRIVER « [RES] [SendData] was sent: true 13:52:23.662 DRIVER send thread state: sending.execute 13:52:23.677 SERIAL « 0x01070013c40000032c (9 bytes) 13:52:23.677 SERIAL » [ACK] (0x06) 13:52:23.677 DRIVER « [REQ] [SendData] callback id: 196 transmit status: OK 13:52:23.679 DRIVER send thread state: sending.execute 13:52:23.679 DRIVER send thread state: sending.waitForUpdate 13:52:23.688 SERIAL « 0x010b000400060570061d010099 (13 bytes) 13:52:23.692 CNTRLR [Node 006] [+] [Configuration] 29: 0 13:52:23.693 SERIAL » [ACK] (0x06) 13:52:23.694 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 29 value size: 1 value: 0 13:52:23.695 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.695 DRIVER send thread state: idle 13:52:23.695 CNTRLR « [Node 006] parameter #29 has value: 0 13:52:23.695 CNTRLR » [Node 006] querying parameter #30 value... 13:52:23.697 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.699 SERIAL » 0x010a0013060370051e25c568 (12 bytes) 13:52:23.699 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 197 └─[ConfigurationCCGet] parameter #: 30 13:52:23.699 DRIVER send thread state: sending.execute 13:52:23.701 SERIAL « [ACK] (0x06) 13:52:23.702 DRIVER send thread state: sending.execute 13:52:23.709 SERIAL « 0x0104011301e8 (6 bytes) 13:52:23.709 SERIAL » [ACK] (0x06) 13:52:23.710 DRIVER « [RES] [SendData] was sent: true 13:52:23.711 DRIVER send thread state: sending.execute 13:52:23.723 SERIAL « 0x01070013c50000022c (9 bytes) 13:52:23.724 SERIAL » [ACK] (0x06) 13:52:23.724 DRIVER « [REQ] [SendData] callback id: 197 transmit status: OK 13:52:23.726 DRIVER send thread state: sending.execute 13:52:23.726 DRIVER send thread state: sending.waitForUpdate 13:52:23.735 SERIAL « 0x010b000400060570061e01009a (13 bytes) 13:52:23.740 CNTRLR [Node 006] [+] [Configuration] 30: 0 13:52:23.741 SERIAL » [ACK] (0x06) 13:52:23.741 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 30 value size: 1 value: 0 13:52:23.742 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.742 DRIVER send thread state: idle 13:52:23.742 CNTRLR « [Node 006] parameter #30 has value: 0 13:52:23.743 CNTRLR » [Node 006] querying parameter #31 value... 13:52:23.744 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.746 SERIAL » 0x010a0013060370051f25c66a (12 bytes) 13:52:23.746 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 198 └─[ConfigurationCCGet] parameter #: 31 13:52:23.747 DRIVER send thread state: sending.execute 13:52:23.749 SERIAL « [ACK] (0x06) 13:52:23.750 DRIVER send thread state: sending.execute 13:52:23.754 SERIAL « 0x0104011301e8 (6 bytes) 13:52:23.755 SERIAL » [ACK] (0x06) 13:52:23.755 DRIVER « [RES] [SendData] was sent: true 13:52:23.756 DRIVER send thread state: sending.execute 13:52:23.771 SERIAL « 0x01070013c60000022f (9 bytes) 13:52:23.771 SERIAL » [ACK] (0x06) 13:52:23.772 DRIVER « [REQ] [SendData] callback id: 198 transmit status: OK 13:52:23.773 DRIVER send thread state: sending.execute 13:52:23.773 DRIVER send thread state: sending.waitForUpdate 13:52:23.783 SERIAL « 0x010c000400060670061f0200ff63 (14 bytes) 13:52:23.787 CNTRLR [Node 006] [+] [Configuration] 31: 255 13:52:23.788 SERIAL » [ACK] (0x06) 13:52:23.789 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 31 value size: 2 value: 255 13:52:23.789 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.790 DRIVER send thread state: idle 13:52:23.790 CNTRLR « [Node 006] parameter #31 has value: 255 13:52:23.790 CNTRLR » [Node 006] querying parameter #32 value... 13:52:23.791 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.796 SERIAL » 0x010a0013060370052025c754 (12 bytes) 13:52:23.797 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 199 └─[ConfigurationCCGet] parameter #: 32 13:52:23.797 DRIVER send thread state: sending.execute 13:52:23.799 SERIAL « [ACK] (0x06) 13:52:23.800 DRIVER send thread state: sending.execute 13:52:23.805 SERIAL « 0x0104011301e8 (6 bytes) 13:52:23.805 SERIAL » [ACK] (0x06) 13:52:23.806 DRIVER « [RES] [SendData] was sent: true 13:52:23.806 DRIVER send thread state: sending.execute 13:52:23.821 SERIAL « 0x01070013c70000022e (9 bytes) 13:52:23.821 SERIAL » [ACK] (0x06) 13:52:23.822 DRIVER « [REQ] [SendData] callback id: 199 transmit status: OK 13:52:23.822 DRIVER send thread state: sending.execute 13:52:23.822 DRIVER send thread state: sending.waitForUpdate 13:52:23.833 SERIAL « 0x010c0004000606700620020000a3 (14 bytes) 13:52:23.834 CNTRLR [Node 006] [+] [Configuration] 32: 0 13:52:23.835 SERIAL » [ACK] (0x06) 13:52:23.835 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 32 value size: 2 value: 0 13:52:23.835 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.835 DRIVER send thread state: idle 13:52:23.835 CNTRLR « [Node 006] parameter #32 has value: 0 13:52:23.835 CNTRLR » [Node 006] querying parameter #33 value... 13:52:23.836 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.837 SERIAL » 0x010a0013060370052125c85a (12 bytes) 13:52:23.837 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 200 └─[ConfigurationCCGet] parameter #: 33 13:52:23.837 DRIVER send thread state: sending.execute 13:52:23.838 SERIAL « [ACK] (0x06) 13:52:23.839 DRIVER send thread state: sending.execute 13:52:23.844 SERIAL « 0x0104011301e8 (6 bytes) 13:52:23.845 SERIAL » [ACK] (0x06) 13:52:23.845 DRIVER « [RES] [SendData] was sent: true 13:52:23.845 DRIVER send thread state: sending.execute 13:52:23.861 SERIAL « 0x01070013c800000221 (9 bytes) 13:52:23.861 SERIAL » [ACK] (0x06) 13:52:23.862 DRIVER « [REQ] [SendData] callback id: 200 transmit status: OK 13:52:23.862 DRIVER send thread state: sending.execute 13:52:23.862 DRIVER send thread state: sending.waitForUpdate 13:52:23.873 SERIAL « 0x010c0004000606700621020063c1 (14 bytes) 13:52:23.875 CNTRLR [Node 006] [+] [Configuration] 33: 99 13:52:23.876 SERIAL » [ACK] (0x06) 13:52:23.876 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 33 value size: 2 value: 99 13:52:23.877 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.877 DRIVER send thread state: idle 13:52:23.877 CNTRLR « [Node 006] parameter #33 has value: 99 13:52:23.877 CNTRLR » [Node 006] querying parameter #35 value... 13:52:23.878 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.880 SERIAL » 0x010a0013060370052325c959 (12 bytes) 13:52:23.880 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 201 └─[ConfigurationCCGet] parameter #: 35 13:52:23.880 DRIVER send thread state: sending.execute 13:52:23.881 SERIAL « [ACK] (0x06) 13:52:23.882 DRIVER send thread state: sending.execute 13:52:23.888 SERIAL « 0x0104011301e8 (6 bytes) 13:52:23.888 SERIAL » [ACK] (0x06) 13:52:23.888 DRIVER « [RES] [SendData] was sent: true 13:52:23.889 DRIVER send thread state: sending.execute 13:52:23.904 SERIAL « 0x01070013c900000220 (9 bytes) 13:52:23.904 SERIAL » [ACK] (0x06) 13:52:23.905 DRIVER « [REQ] [SendData] callback id: 201 transmit status: OK 13:52:23.906 DRIVER send thread state: sending.execute 13:52:23.907 DRIVER send thread state: sending.waitForUpdate 13:52:23.916 SERIAL « 0x010b00040006057006230100a7 (13 bytes) 13:52:23.920 CNTRLR [Node 006] [+] [Configuration] 35: 0 13:52:23.921 SERIAL » [ACK] (0x06) 13:52:23.922 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 35 value size: 1 value: 0 13:52:23.923 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.923 DRIVER send thread state: idle 13:52:23.923 CNTRLR « [Node 006] parameter #35 has value: 0 13:52:23.923 CNTRLR » [Node 006] querying parameter #36 value... 13:52:23.925 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.927 SERIAL » 0x010a0013060370052425ca5d (12 bytes) 13:52:23.927 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 202 └─[ConfigurationCCGet] parameter #: 36 13:52:23.927 DRIVER send thread state: sending.execute 13:52:23.929 SERIAL « [ACK] (0x06) 13:52:23.930 DRIVER send thread state: sending.execute 13:52:23.935 SERIAL « 0x0104011301e8 (6 bytes) 13:52:23.935 SERIAL » [ACK] (0x06) 13:52:23.936 DRIVER « [RES] [SendData] was sent: true 13:52:23.937 DRIVER send thread state: sending.execute 13:52:23.951 SERIAL « 0x01070013ca00000223 (9 bytes) 13:52:23.952 SERIAL » [ACK] (0x06) 13:52:23.952 DRIVER « [REQ] [SendData] callback id: 202 transmit status: OK 13:52:23.954 DRIVER send thread state: sending.execute 13:52:23.954 DRIVER send thread state: sending.waitForUpdate 13:52:23.963 SERIAL « 0x010c00040006067006240200ff58 (14 bytes) 13:52:23.968 CNTRLR [Node 006] [+] [Configuration] 36: 255 13:52:23.968 SERIAL » [ACK] (0x06) 13:52:23.969 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 36 value size: 2 value: 255 13:52:23.970 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.970 DRIVER send thread state: idle 13:52:23.970 CNTRLR « [Node 006] parameter #36 has value: 255 13:52:23.970 CNTRLR » [Node 006] querying parameter #37 value... 13:52:23.972 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:23.974 SERIAL » 0x010a0013060370052525cb5d (12 bytes) 13:52:23.974 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 203 └─[ConfigurationCCGet] parameter #: 37 13:52:23.974 DRIVER send thread state: sending.execute 13:52:23.977 SERIAL « [ACK] (0x06) 13:52:23.979 DRIVER send thread state: sending.execute 13:52:23.983 SERIAL « 0x0104011301e8 (6 bytes) 13:52:23.983 SERIAL » [ACK] (0x06) 13:52:23.983 DRIVER « [RES] [SendData] was sent: true 13:52:23.985 DRIVER send thread state: sending.execute 13:52:23.999 SERIAL « 0x01070013cb00000222 (9 bytes) 13:52:23.999 SERIAL » [ACK] (0x06) 13:52:23.999 DRIVER « [REQ] [SendData] callback id: 203 transmit status: OK 13:52:24.001 DRIVER send thread state: sending.execute 13:52:24.001 DRIVER send thread state: sending.waitForUpdate 13:52:24.011 SERIAL « 0x010c0004000606700625020000a6 (14 bytes) 13:52:24.015 CNTRLR [Node 006] [+] [Configuration] 37: 0 13:52:24.016 SERIAL » [ACK] (0x06) 13:52:24.017 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 37 value size: 2 value: 0 13:52:24.018 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.018 DRIVER send thread state: idle 13:52:24.018 CNTRLR « [Node 006] parameter #37 has value: 0 13:52:24.018 CNTRLR » [Node 006] querying parameter #38 value... 13:52:24.020 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.022 SERIAL » 0x010a0013060370052625cc59 (12 bytes) 13:52:24.022 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 204 └─[ConfigurationCCGet] parameter #: 38 13:52:24.023 DRIVER send thread state: sending.execute 13:52:24.024 SERIAL « [ACK] (0x06) 13:52:24.028 DRIVER send thread state: sending.execute 13:52:24.030 SERIAL « 0x0104011301e8 (6 bytes) 13:52:24.031 SERIAL » [ACK] (0x06) 13:52:24.031 DRIVER « [RES] [SendData] was sent: true 13:52:24.033 DRIVER send thread state: sending.execute 13:52:24.047 SERIAL « 0x01070013cc00000225 (9 bytes) 13:52:24.047 SERIAL » [ACK] (0x06) 13:52:24.047 DRIVER « [REQ] [SendData] callback id: 204 transmit status: OK 13:52:24.049 DRIVER send thread state: sending.execute 13:52:24.049 DRIVER send thread state: sending.waitForUpdate 13:52:24.058 SERIAL « 0x010c0004000606700626020063c6 (14 bytes) 13:52:24.063 CNTRLR [Node 006] [+] [Configuration] 38: 99 13:52:24.064 SERIAL » [ACK] (0x06) 13:52:24.064 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 38 value size: 2 value: 99 13:52:24.065 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.065 DRIVER send thread state: idle 13:52:24.066 CNTRLR « [Node 006] parameter #38 has value: 99 13:52:24.066 CNTRLR » [Node 006] querying parameter #40 value... 13:52:24.067 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.069 SERIAL » 0x010a0013060370052825cd56 (12 bytes) 13:52:24.070 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 205 └─[ConfigurationCCGet] parameter #: 40 13:52:24.070 DRIVER send thread state: sending.execute 13:52:24.072 SERIAL « [ACK] (0x06) 13:52:24.073 DRIVER send thread state: sending.execute 13:52:24.078 SERIAL « 0x0104011301e8 (6 bytes) 13:52:24.078 SERIAL » [ACK] (0x06) 13:52:24.079 DRIVER « [RES] [SendData] was sent: true 13:52:24.080 DRIVER send thread state: sending.execute 13:52:24.094 SERIAL « 0x01070013cd00000224 (9 bytes) 13:52:24.094 SERIAL » [ACK] (0x06) 13:52:24.095 DRIVER « [REQ] [SendData] callback id: 205 transmit status: OK 13:52:24.096 DRIVER send thread state: sending.execute 13:52:24.096 DRIVER send thread state: sending.waitForUpdate 13:52:24.105 SERIAL « 0x010b00040006057006280103af (13 bytes) 13:52:24.110 CNTRLR [Node 006] [+] [Configuration] 40: 3 13:52:24.110 SERIAL » [ACK] (0x06) 13:52:24.111 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 40 value size: 1 value: 3 13:52:24.112 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.112 DRIVER send thread state: idle 13:52:24.112 CNTRLR « [Node 006] parameter #40 has value: 3 13:52:24.112 CNTRLR » [Node 006] querying parameter #41 value... 13:52:24.114 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.116 SERIAL » 0x010a0013060370052925ce54 (12 bytes) 13:52:24.116 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 206 └─[ConfigurationCCGet] parameter #: 41 13:52:24.117 DRIVER send thread state: sending.execute 13:52:24.118 SERIAL « [ACK] (0x06) 13:52:24.119 DRIVER send thread state: sending.execute 13:52:24.125 SERIAL « 0x0104011301e8 (6 bytes) 13:52:24.125 SERIAL » [ACK] (0x06) 13:52:24.125 DRIVER « [RES] [SendData] was sent: true 13:52:24.127 DRIVER send thread state: sending.execute 13:52:24.140 SERIAL « 0x01070013ce00000227 (9 bytes) 13:52:24.141 SERIAL » [ACK] (0x06) 13:52:24.141 DRIVER « [REQ] [SendData] callback id: 206 transmit status: OK 13:52:24.143 DRIVER send thread state: sending.execute 13:52:24.143 DRIVER send thread state: sending.waitForUpdate 13:52:24.152 SERIAL « 0x010b00040006057006290102af (13 bytes) 13:52:24.157 CNTRLR [Node 006] [+] [Configuration] 41: 2 13:52:24.158 SERIAL » [ACK] (0x06) 13:52:24.158 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 41 value size: 1 value: 2 13:52:24.159 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.159 DRIVER send thread state: idle 13:52:24.159 CNTRLR « [Node 006] parameter #41 has value: 2 13:52:24.160 CNTRLR » [Node 006] querying parameter #42 value... 13:52:24.161 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.163 SERIAL » 0x010a0013060370052a25cf56 (12 bytes) 13:52:24.163 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 207 └─[ConfigurationCCGet] parameter #: 42 13:52:24.164 DRIVER send thread state: sending.execute 13:52:24.165 SERIAL « [ACK] (0x06) 13:52:24.166 DRIVER send thread state: sending.execute 13:52:24.171 SERIAL « 0x0104011301e8 (6 bytes) 13:52:24.172 SERIAL » [ACK] (0x06) 13:52:24.172 DRIVER « [RES] [SendData] was sent: true 13:52:24.173 DRIVER send thread state: sending.execute 13:52:24.188 SERIAL « 0x01070013cf00000226 (9 bytes) 13:52:24.189 SERIAL » [ACK] (0x06) 13:52:24.189 DRIVER « [REQ] [SendData] callback id: 207 transmit status: OK 13:52:24.191 DRIVER send thread state: sending.execute 13:52:24.191 DRIVER send thread state: sending.waitForUpdate 13:52:24.199 SERIAL « 0x010b000400060570062a0103ad (13 bytes) 13:52:24.204 CNTRLR [Node 006] [+] [Configuration] 42: 3 13:52:24.205 SERIAL » [ACK] (0x06) 13:52:24.206 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 42 value size: 1 value: 3 13:52:24.206 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.207 DRIVER send thread state: idle 13:52:24.207 CNTRLR « [Node 006] parameter #42 has value: 3 13:52:24.207 CNTRLR » [Node 006] querying parameter #43 value... 13:52:24.209 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.218 SERIAL » 0x010a0013060370052b25d048 (12 bytes) 13:52:24.218 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 208 └─[ConfigurationCCGet] parameter #: 43 13:52:24.219 DRIVER send thread state: sending.execute 13:52:24.223 SERIAL « [ACK] (0x06) 13:52:24.224 DRIVER send thread state: sending.execute 13:52:24.226 SERIAL « 0x0104011301e8 (6 bytes) 13:52:24.227 SERIAL » [ACK] (0x06) 13:52:24.227 DRIVER « [RES] [SendData] was sent: true 13:52:24.228 DRIVER send thread state: sending.execute 13:52:24.243 SERIAL « 0x01070013d000000239 (9 bytes) 13:52:24.243 SERIAL » [ACK] (0x06) 13:52:24.243 DRIVER « [REQ] [SendData] callback id: 208 transmit status: OK 13:52:24.244 DRIVER send thread state: sending.execute 13:52:24.244 DRIVER send thread state: sending.waitForUpdate 13:52:24.255 SERIAL « 0x010b000400060570062b0101ae (13 bytes) 13:52:24.256 CNTRLR [Node 006] [+] [Configuration] 43: 1 13:52:24.256 SERIAL » [ACK] (0x06) 13:52:24.257 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 43 value size: 1 value: 1 13:52:24.257 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.257 DRIVER send thread state: idle 13:52:24.257 CNTRLR « [Node 006] parameter #43 has value: 1 13:52:24.257 CNTRLR » [Node 006] querying parameter #44 value... 13:52:24.258 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.259 SERIAL » 0x010a0013060370052c25d14e (12 bytes) 13:52:24.259 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 209 └─[ConfigurationCCGet] parameter #: 44 13:52:24.259 DRIVER send thread state: sending.execute 13:52:24.260 SERIAL « [ACK] (0x06) 13:52:24.261 DRIVER send thread state: sending.execute 13:52:24.266 SERIAL « 0x0104011301e8 (6 bytes) 13:52:24.266 SERIAL » [ACK] (0x06) 13:52:24.267 DRIVER « [RES] [SendData] was sent: true 13:52:24.267 DRIVER send thread state: sending.execute 13:52:24.283 SERIAL « 0x01070013d100000238 (9 bytes) 13:52:24.283 SERIAL » [ACK] (0x06) 13:52:24.283 DRIVER « [REQ] [SendData] callback id: 209 transmit status: OK 13:52:24.284 DRIVER send thread state: sending.execute 13:52:24.284 DRIVER send thread state: sending.waitForUpdate 13:52:24.295 SERIAL « 0x010c000400060670062c020258f5 (14 bytes) 13:52:24.297 CNTRLR [Node 006] [+] [Configuration] 44: 600 13:52:24.297 SERIAL » [ACK] (0x06) 13:52:24.297 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 44 value size: 2 value: 600 13:52:24.297 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.298 DRIVER send thread state: idle 13:52:24.298 CNTRLR « [Node 006] parameter #44 has value: 600 13:52:24.298 CNTRLR » [Node 006] querying parameter #50 value... 13:52:24.298 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.299 SERIAL » 0x010a0013060370053225d253 (12 bytes) 13:52:24.299 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 210 └─[ConfigurationCCGet] parameter #: 50 13:52:24.300 DRIVER send thread state: sending.execute 13:52:24.301 SERIAL « [ACK] (0x06) 13:52:24.301 DRIVER send thread state: sending.execute 13:52:24.307 SERIAL « 0x0104011301e8 (6 bytes) 13:52:24.308 SERIAL » [ACK] (0x06) 13:52:24.308 DRIVER « [RES] [SendData] was sent: true 13:52:24.308 DRIVER send thread state: sending.execute 13:52:24.323 SERIAL « 0x01070013d20000023b (9 bytes) 13:52:24.324 SERIAL » [ACK] (0x06) 13:52:24.324 DRIVER « [REQ] [SendData] callback id: 210 transmit status: OK 13:52:24.325 DRIVER send thread state: sending.execute 13:52:24.325 DRIVER send thread state: sending.waitForUpdate 13:52:24.335 SERIAL « 0x010b00040006057006320114a2 (13 bytes) 13:52:24.340 CNTRLR [Node 006] [+] [Configuration] 50: 20 13:52:24.340 SERIAL » [ACK] (0x06) 13:52:24.341 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 50 value size: 1 value: 20 13:52:24.342 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.342 DRIVER send thread state: idle 13:52:24.342 CNTRLR « [Node 006] parameter #50 has value: 20 13:52:24.343 CNTRLR » [Node 006] querying parameter #51 value... 13:52:24.344 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.346 SERIAL » 0x010a0013060370053325d353 (12 bytes) 13:52:24.346 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 211 └─[ConfigurationCCGet] parameter #: 51 13:52:24.347 DRIVER send thread state: sending.execute 13:52:24.348 SERIAL « [ACK] (0x06) 13:52:24.349 DRIVER send thread state: sending.execute 13:52:24.355 SERIAL « 0x0104011301e8 (6 bytes) 13:52:24.356 SERIAL » [ACK] (0x06) 13:52:24.356 DRIVER « [RES] [SendData] was sent: true 13:52:24.357 DRIVER send thread state: sending.execute 13:52:24.371 SERIAL « 0x01070013d30000023a (9 bytes) 13:52:24.371 SERIAL » [ACK] (0x06) 13:52:24.372 DRIVER « [REQ] [SendData] callback id: 211 transmit status: OK 13:52:24.373 DRIVER send thread state: sending.execute 13:52:24.373 DRIVER send thread state: sending.waitForUpdate 13:52:24.383 SERIAL « 0x010b0004000605700633010abd (13 bytes) 13:52:24.386 CNTRLR [Node 006] [+] [Configuration] 51: 10 13:52:24.386 SERIAL » [ACK] (0x06) 13:52:24.387 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 51 value size: 1 value: 10 13:52:24.387 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.388 DRIVER send thread state: idle 13:52:24.388 CNTRLR « [Node 006] parameter #51 has value: 10 13:52:24.388 CNTRLR » [Node 006] querying parameter #53 value... 13:52:24.389 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.390 SERIAL » 0x010a0013060370053525d452 (12 bytes) 13:52:24.390 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 212 └─[ConfigurationCCGet] parameter #: 53 13:52:24.390 DRIVER send thread state: sending.execute 13:52:24.392 SERIAL « [ACK] (0x06) 13:52:24.393 DRIVER send thread state: sending.execute 13:52:24.398 SERIAL « 0x0104011301e8 (6 bytes) 13:52:24.399 SERIAL » [ACK] (0x06) 13:52:24.399 DRIVER « [RES] [SendData] was sent: true 13:52:24.400 DRIVER send thread state: sending.execute 13:52:24.414 SERIAL « 0x01070013d40000023d (9 bytes) 13:52:24.415 SERIAL » [ACK] (0x06) 13:52:24.415 DRIVER « [REQ] [SendData] callback id: 212 transmit status: OK 13:52:24.417 DRIVER send thread state: sending.execute 13:52:24.417 DRIVER send thread state: sending.waitForUpdate 13:52:24.426 SERIAL « 0x010c0004000606700635020064d2 (14 bytes) 13:52:24.431 CNTRLR [Node 006] [+] [Configuration] 53: 100 13:52:24.432 SERIAL » [ACK] (0x06) 13:52:24.432 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 53 value size: 2 value: 100 13:52:24.433 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.433 DRIVER send thread state: idle 13:52:24.433 CNTRLR « [Node 006] parameter #53 has value: 100 13:52:24.434 CNTRLR » [Node 006] querying parameter #54 value... 13:52:24.435 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.437 SERIAL » 0x010a0013060370053625d550 (12 bytes) 13:52:24.438 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 213 └─[ConfigurationCCGet] parameter #: 54 13:52:24.438 DRIVER send thread state: sending.execute 13:52:24.441 SERIAL « [ACK] (0x06) 13:52:24.442 DRIVER send thread state: sending.execute 13:52:24.446 SERIAL « 0x0104011301e8 (6 bytes) 13:52:24.446 SERIAL » [ACK] (0x06) 13:52:24.448 DRIVER « [RES] [SendData] was sent: true 13:52:24.449 DRIVER send thread state: sending.execute 13:52:24.507 SERIAL « 0x010c0004003606310504220818c5 (14 bytes) 13:52:24.508 CNTRLR [Node 054] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 13:52:24.508 CNTRLR [Node 054] [~] [Multilevel Sensor] Power: 114.8 => 207.2 [Endpoint 0] 13:52:24.509 SERIAL » [ACK] (0x06) 13:52:24.509 DRIVER « [Node 054] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 207.2 13:52:24.510 DRIVER send thread state: sending.execute 13:52:24.511 DRIVER send thread state: sending.execute 13:52:24.519 SERIAL « 0x010c0004000606700635020064d2 (14 bytes) 13:52:24.524 CNTRLR [Node 006] [~] [Configuration] 53: 100 => 100 13:52:24.525 SERIAL » [ACK] (0x06) 13:52:24.525 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 53 value size: 2 value: 100 13:52:24.526 DRIVER send thread state: sending.execute 13:52:24.526 DRIVER send thread state: sending.execute 13:52:24.533 SERIAL « 0x01070013d500000937 (9 bytes) 13:52:24.533 SERIAL » [ACK] (0x06) 13:52:24.534 DRIVER « [REQ] [SendData] callback id: 213 transmit status: OK 13:52:24.535 DRIVER send thread state: sending.execute 13:52:24.535 DRIVER send thread state: sending.waitForUpdate 13:52:24.577 SERIAL « 0x010b00040006057006360114a6 (13 bytes) 13:52:24.579 CNTRLR [Node 006] [+] [Configuration] 54: 20 13:52:24.579 SERIAL » [ACK] (0x06) 13:52:24.579 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 54 value size: 1 value: 20 13:52:24.580 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.580 DRIVER send thread state: idle 13:52:24.580 CNTRLR « [Node 006] parameter #54 has value: 20 13:52:24.580 CNTRLR » [Node 006] querying parameter #55 value... 13:52:24.581 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.583 SERIAL » 0x010a0013060370053725d652 (12 bytes) 13:52:24.583 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 214 └─[ConfigurationCCGet] parameter #: 55 13:52:24.583 DRIVER send thread state: sending.execute 13:52:24.585 SERIAL « [ACK] (0x06) 13:52:24.585 DRIVER send thread state: sending.execute 13:52:24.591 SERIAL « 0x0104011301e8 (6 bytes) 13:52:24.591 SERIAL » [ACK] (0x06) 13:52:24.592 DRIVER « [RES] [SendData] was sent: true 13:52:24.592 DRIVER send thread state: sending.execute 13:52:24.644 SERIAL « 0x010b00040006057006360114a6 (13 bytes) 13:52:24.648 CNTRLR [Node 006] [~] [Configuration] 54: 20 => 20 13:52:24.649 SERIAL » [ACK] (0x06) 13:52:24.650 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 54 value size: 1 value: 20 13:52:24.651 DRIVER send thread state: sending.execute 13:52:24.651 DRIVER send thread state: sending.execute 13:52:24.701 SERIAL « 0x010b00040006057006360114a6 (13 bytes) 13:52:24.706 CNTRLR [Node 006] [~] [Configuration] 54: 20 => 20 13:52:24.706 SERIAL » [ACK] (0x06) 13:52:24.707 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 54 value size: 1 value: 20 13:52:24.708 DRIVER send thread state: sending.execute 13:52:24.708 DRIVER send thread state: sending.execute 13:52:24.743 SERIAL « 0x01070013d600000f32 (9 bytes) 13:52:24.743 SERIAL » [ACK] (0x06) 13:52:24.744 DRIVER « [REQ] [SendData] callback id: 214 transmit status: OK 13:52:24.749 DRIVER send thread state: sending.execute 13:52:24.749 DRIVER send thread state: sending.waitForUpdate 13:52:24.755 SERIAL « 0x010b0004000605700637010ab9 (13 bytes) 13:52:24.760 CNTRLR [Node 006] [+] [Configuration] 55: 10 13:52:24.761 SERIAL » [ACK] (0x06) 13:52:24.761 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 55 value size: 1 value: 10 13:52:24.762 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.763 DRIVER send thread state: idle 13:52:24.763 CNTRLR « [Node 006] parameter #55 has value: 10 13:52:24.763 CNTRLR » [Node 006] querying parameter #57 value... 13:52:24.764 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.767 SERIAL » 0x010a0013060370053925d75d (12 bytes) 13:52:24.767 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 215 └─[ConfigurationCCGet] parameter #: 57 13:52:24.767 DRIVER send thread state: sending.execute 13:52:24.769 SERIAL « [ACK] (0x06) 13:52:24.771 DRIVER send thread state: sending.execute 13:52:24.775 SERIAL « 0x0104011301e8 (6 bytes) 13:52:24.775 SERIAL » [ACK] (0x06) 13:52:24.776 DRIVER « [RES] [SendData] was sent: true 13:52:24.777 DRIVER send thread state: sending.execute 13:52:24.791 SERIAL « 0x01070013d70000023e (9 bytes) 13:52:24.792 SERIAL » [ACK] (0x06) 13:52:24.792 DRIVER « [REQ] [SendData] callback id: 215 transmit status: OK 13:52:24.794 DRIVER send thread state: sending.execute 13:52:24.794 DRIVER send thread state: sending.waitForUpdate 13:52:24.803 SERIAL « 0x010c0004000606700639020064de (14 bytes) 13:52:24.807 CNTRLR [Node 006] [+] [Configuration] 57: 100 13:52:24.808 SERIAL » [ACK] (0x06) 13:52:24.809 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 57 value size: 2 value: 100 13:52:24.809 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.810 DRIVER send thread state: idle 13:52:24.810 CNTRLR « [Node 006] parameter #57 has value: 100 13:52:24.810 CNTRLR » [Node 006] querying parameter #58 value... 13:52:24.812 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.814 SERIAL » 0x010a0013060370053a25d851 (12 bytes) 13:52:24.815 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 216 └─[ConfigurationCCGet] parameter #: 58 13:52:24.815 DRIVER send thread state: sending.execute 13:52:24.817 SERIAL « [ACK] (0x06) 13:52:24.820 DRIVER send thread state: sending.execute 13:52:24.823 SERIAL « 0x0104011301e8 (6 bytes) 13:52:24.823 SERIAL » [ACK] (0x06) 13:52:24.824 DRIVER « [RES] [SendData] was sent: true 13:52:24.825 DRIVER send thread state: sending.execute 13:52:24.839 SERIAL « 0x01070013d800000231 (9 bytes) 13:52:24.839 SERIAL » [ACK] (0x06) 13:52:24.840 DRIVER « [REQ] [SendData] callback id: 216 transmit status: OK 13:52:24.841 DRIVER send thread state: sending.execute 13:52:24.842 DRIVER send thread state: sending.waitForUpdate 13:52:24.851 SERIAL « 0x010c000400060670063a020e10a7 (14 bytes) 13:52:24.855 CNTRLR [Node 006] [+] [Configuration] 58: 3600 13:52:24.856 SERIAL » [ACK] (0x06) 13:52:24.857 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 58 value size: 2 value: 3600 13:52:24.857 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.858 DRIVER send thread state: idle 13:52:24.858 CNTRLR « [Node 006] parameter #58 has value: 3600 13:52:24.858 CNTRLR » [Node 006] querying parameter #59 value... 13:52:24.859 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.862 SERIAL » 0x010a0013060370053b25d951 (12 bytes) 13:52:24.862 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 217 └─[ConfigurationCCGet] parameter #: 59 13:52:24.862 DRIVER send thread state: sending.execute 13:52:24.864 SERIAL « [ACK] (0x06) 13:52:24.865 DRIVER send thread state: sending.execute 13:52:24.870 SERIAL « 0x0104011301e8 (6 bytes) 13:52:24.870 SERIAL » [ACK] (0x06) 13:52:24.871 DRIVER « [RES] [SendData] was sent: true 13:52:24.872 DRIVER send thread state: sending.execute 13:52:24.886 SERIAL « 0x01070013d900000331 (9 bytes) 13:52:24.886 SERIAL » [ACK] (0x06) 13:52:24.887 DRIVER « [REQ] [SendData] callback id: 217 transmit status: OK 13:52:24.888 DRIVER send thread state: sending.execute 13:52:24.889 DRIVER send thread state: sending.waitForUpdate 13:52:24.898 SERIAL « 0x010c000400060670063b020e10a6 (14 bytes) 13:52:24.902 CNTRLR [Node 006] [+] [Configuration] 59: 3600 13:52:24.903 SERIAL » [ACK] (0x06) 13:52:24.904 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 59 value size: 2 value: 3600 13:52:24.905 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.905 DRIVER send thread state: idle 13:52:24.905 CNTRLR « [Node 006] parameter #59 has value: 3600 13:52:24.905 CNTRLR » [Node 006] querying parameter #60 value... 13:52:24.907 DRIVER Send queue: (2 messages) · [REQ] SendData (ConfigurationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.913 SERIAL » 0x010a0013060370053c25da55 (12 bytes) 13:52:24.913 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 218 └─[ConfigurationCCGet] parameter #: 60 13:52:24.913 DRIVER send thread state: sending.execute 13:52:24.916 SERIAL « [ACK] (0x06) 13:52:24.916 DRIVER send thread state: sending.execute 13:52:24.922 SERIAL « 0x0104011301e8 (6 bytes) 13:52:24.922 SERIAL » [ACK] (0x06) 13:52:24.923 DRIVER « [RES] [SendData] was sent: true 13:52:24.924 DRIVER send thread state: sending.execute 13:52:24.938 SERIAL « 0x01070013da00000233 (9 bytes) 13:52:24.938 SERIAL » [ACK] (0x06) 13:52:24.938 DRIVER « [REQ] [SendData] callback id: 218 transmit status: OK 13:52:24.939 DRIVER send thread state: sending.execute 13:52:24.939 DRIVER send thread state: sending.waitForUpdate 13:52:24.949 SERIAL « 0x010b000400060570063c0100b8 (13 bytes) 13:52:24.953 CNTRLR [Node 006] [+] [Configuration] 60: 0 13:52:24.954 SERIAL » [ACK] (0x06) 13:52:24.954 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ConfigurationCCReport] parameter #: 60 value size: 1 value: 0 13:52:24.954 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.954 DRIVER send thread state: idle 13:52:24.954 CNTRLR « [Node 006] parameter #60 has value: 0 13:52:24.955 CNTRLR [Node 006] [+] [Configuration] interviewComplete: true [Endpoint 0] [internal] 13:52:24.961 CNTRLR [Node 006] MeterCC: doing a complete interview... 13:52:24.961 CNTRLR » [Node 006] querying meter support... 13:52:24.962 DRIVER Send queue: (2 messages) · [REQ] SendData (MeterCCSupportedGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:24.963 SERIAL » 0x010900130602320325db2e (11 bytes) 13:52:24.963 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 219 └─[MeterCCSupportedGet] 13:52:24.963 DRIVER send thread state: sending.execute 13:52:24.971 SERIAL « [ACK] (0x06) 13:52:24.973 DRIVER send thread state: sending.execute 13:52:24.974 SERIAL « 0x0104011301e8 (6 bytes) 13:52:24.974 SERIAL » [ACK] (0x06) 13:52:24.974 DRIVER « [RES] [SendData] was sent: true 13:52:24.975 DRIVER send thread state: sending.execute 13:52:24.988 SERIAL « 0x01070013db00000232 (9 bytes) 13:52:24.988 SERIAL » [ACK] (0x06) 13:52:24.989 DRIVER « [REQ] [SendData] callback id: 219 transmit status: OK 13:52:24.989 DRIVER send thread state: sending.execute 13:52:24.989 DRIVER send thread state: sending.waitForUpdate 13:52:24.998 SERIAL « 0x010a00040006043204810541 (12 bytes) 13:52:24.999 CNTRLR [Node 006] [+] [Meter] type: 1 [Endpoint 0] [internal] 13:52:24.999 CNTRLR [Node 006] [+] [Meter] supportsReset: true [Endpoint 0] [internal] 13:52:24.999 CNTRLR [Node 006] [+] [Meter] supportedScales: 0,2 [Endpoint 0] [internal] 13:52:24.999 CNTRLR [Node 006] [+] [Meter] supportedRateTypes: [Endpoint 0] [internal] 13:52:25.000 CNTRLR [Node 006] [Meter] reset: metadata updated [Endpoint 0] 13:52:25.000 SERIAL » [ACK] (0x06) 13:52:25.000 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCSupportedReport] type: Electric supports reset: true supported scales: · kWh · W supported rate types: 13:52:25.001 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.001 DRIVER send thread state: idle 13:52:25.001 CNTRLR « [Node 006] received meter support: type: Electric supported scales: · kWh · W supported rate types: supports reset: true 13:52:25.001 CNTRLR » [Node 006] querying meter value (type = Electric, scale = kWh)... 13:52:25.001 DRIVER Send queue: (2 messages) · [REQ] SendData (MeterCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.002 SERIAL » 0x010a0013060332010025dc29 (12 bytes) 13:52:25.002 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 220 └─[MeterCCGet] duration: kWh 13:52:25.003 DRIVER send thread state: sending.execute 13:52:25.004 SERIAL « [ACK] (0x06) 13:52:25.004 DRIVER send thread state: sending.execute 13:52:25.010 SERIAL « 0x0104011301e8 (6 bytes) 13:52:25.010 SERIAL » [ACK] (0x06) 13:52:25.010 DRIVER « [RES] [SendData] was sent: true 13:52:25.011 DRIVER send thread state: sending.execute 13:52:25.026 SERIAL « 0x01070013dc00000334 (9 bytes) 13:52:25.027 SERIAL » [ACK] (0x06) 13:52:25.027 DRIVER « [REQ] [SendData] callback id: 220 transmit status: OK 13:52:25.027 DRIVER send thread state: sending.execute 13:52:25.028 DRIVER send thread state: sending.waitForUpdate 13:52:25.039 SERIAL « 0x0110000400060a32022144000000000000b2 (18 bytes) 13:52:25.039 CNTRLR [Node 006] [Meter] value[65537]: metadata updated [Endpoint 0] 13:52:25.039 CNTRLR [Node 006] [Meter] previousValue[65537]: metadata updated [Endpoint 0] 13:52:25.040 CNTRLR [Node 006] [Meter] deltaTime[65537]: metadata updated [Endpoint 0] 13:52:25.040 CNTRLR [Node 006] [+] [Meter] value[65537]: 0 [Endpoint 0] 13:52:25.040 CNTRLR [Node 006] [+] [Meter] deltaTime[65537]: 0 [Endpoint 0] 13:52:25.040 SERIAL » [ACK] (0x06) 13:52:25.041 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 0 time delta: 0 seconds 13:52:25.041 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.041 DRIVER send thread state: idle 13:52:25.041 CNTRLR » [Node 006] querying meter value (type = Electric, scale = W)... 13:52:25.042 DRIVER Send queue: (2 messages) · [REQ] SendData (MeterCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.043 SERIAL » 0x010a0013060332011025dd38 (12 bytes) 13:52:25.043 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 221 └─[MeterCCGet] duration: W 13:52:25.043 DRIVER send thread state: sending.execute 13:52:25.045 SERIAL « [ACK] (0x06) 13:52:25.045 DRIVER send thread state: sending.execute 13:52:25.051 SERIAL « 0x0104011301e8 (6 bytes) 13:52:25.051 SERIAL » [ACK] (0x06) 13:52:25.051 DRIVER « [RES] [SendData] was sent: true 13:52:25.052 DRIVER send thread state: sending.execute 13:52:25.067 SERIAL « 0x01070013dd00000234 (9 bytes) 13:52:25.067 SERIAL » [ACK] (0x06) 13:52:25.068 DRIVER « [REQ] [SendData] callback id: 221 transmit status: OK 13:52:25.069 DRIVER send thread state: sending.execute 13:52:25.069 DRIVER send thread state: sending.waitForUpdate 13:52:25.079 SERIAL « 0x010e00040006083202213200000000d8 (16 bytes) 13:52:25.080 CNTRLR [Node 006] [Meter] value[66049]: metadata updated [Endpoint 0] 13:52:25.081 CNTRLR [Node 006] [Meter] previousValue[66049]: metadata updated [Endpoint 0] 13:52:25.081 CNTRLR [Node 006] [Meter] deltaTime[66049]: metadata updated [Endpoint 0] 13:52:25.081 CNTRLR [Node 006] [+] [Meter] value[66049]: 0 [Endpoint 0] 13:52:25.082 CNTRLR [Node 006] [+] [Meter] deltaTime[66049]: 0 [Endpoint 0] 13:52:25.082 SERIAL » [ACK] (0x06) 13:52:25.083 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 13:52:25.084 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.084 DRIVER send thread state: idle 13:52:25.085 CNTRLR [Node 006] [+] [Meter] interviewComplete: true [Endpoint 0] [internal] 13:52:25.085 CNTRLR [Node 006] ProtectionCC: doing a complete interview... 13:52:25.085 CNTRLR » [Node 006] querying protection capabilities... 13:52:25.087 DRIVER Send queue: (2 messages) · [REQ] SendData (ProtectionCCSupportedGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.090 SERIAL » 0x010900130602750425de6b (11 bytes) 13:52:25.090 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 222 └─[ProtectionCCSupportedGet] 13:52:25.090 DRIVER send thread state: sending.execute 13:52:25.092 SERIAL « [ACK] (0x06) 13:52:25.093 DRIVER send thread state: sending.execute 13:52:25.098 SERIAL « 0x0104011301e8 (6 bytes) 13:52:25.098 SERIAL » [ACK] (0x06) 13:52:25.099 DRIVER « [RES] [SendData] was sent: true 13:52:25.100 DRIVER send thread state: sending.execute 13:52:25.114 SERIAL « 0x01070013de00000237 (9 bytes) 13:52:25.114 SERIAL » [ACK] (0x06) 13:52:25.115 DRIVER « [REQ] [SendData] callback id: 222 transmit status: OK 13:52:25.116 DRIVER send thread state: sending.execute 13:52:25.117 DRIVER send thread state: sending.waitForUpdate 13:52:25.126 SERIAL « 0x010d00040006077505000500030081 (15 bytes) 13:52:25.127 CNTRLR [Node 006] [+] [Protection] supportsExclusiveControl: [Endpoint 0] [internal] false 13:52:25.128 CNTRLR [Node 006] [+] [Protection] supportsTimeout: false [Endpoint 0] [internal] 13:52:25.128 CNTRLR [Node 006] [+] [Protection] supportedLocalStates: 0,2 [Endpoint 0] [internal] 13:52:25.128 CNTRLR [Node 006] [+] [Protection] supportedRFStates: 0,1 [Endpoint 0] [internal] 13:52:25.129 CNTRLR [Node 006] [Protection] local: metadata updated [Endpoint 0] 13:52:25.130 CNTRLR [Node 006] [Protection] rf: metadata updated [Endpoint 0] 13:52:25.130 SERIAL » [ACK] (0x06) 13:52:25.131 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ProtectionCCSupportedReport] supports exclusive control: false supports timeout: false local protection states: · Unprotected · NoOperationPossible RF protection states: · Unprotected · NoControl 13:52:25.132 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.132 DRIVER send thread state: idle 13:52:25.133 CNTRLR « [Node 006] received protection capabilities: exclusive control: false timeout: false local protection states: · Unprotected · NoOperationPossible RF protection states: · Unprotected · NoControl 13:52:25.133 CNTRLR » [Node 006] querying protection status... 13:52:25.135 DRIVER Send queue: (2 messages) · [REQ] SendData (ProtectionCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.137 SERIAL » 0x010900130602750225df6c (11 bytes) 13:52:25.137 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 223 └─[ProtectionCCGet] 13:52:25.137 DRIVER send thread state: sending.execute 13:52:25.139 SERIAL « [ACK] (0x06) 13:52:25.141 DRIVER send thread state: sending.execute 13:52:25.145 SERIAL « 0x0104011301e8 (6 bytes) 13:52:25.145 SERIAL » [ACK] (0x06) 13:52:25.146 DRIVER « [RES] [SendData] was sent: true 13:52:25.146 DRIVER send thread state: sending.execute 13:52:25.161 SERIAL « 0x01070013df00000236 (9 bytes) 13:52:25.161 SERIAL » [ACK] (0x06) 13:52:25.162 DRIVER « [REQ] [SendData] callback id: 223 transmit status: OK 13:52:25.163 DRIVER send thread state: sending.execute 13:52:25.163 DRIVER send thread state: sending.waitForUpdate 13:52:25.173 SERIAL « 0x010a00040006047503000085 (12 bytes) 13:52:25.173 CNTRLR [Node 006] [+] [Protection] local: 0 [Endpoint 0] 13:52:25.174 CNTRLR [Node 006] [+] [Protection] rf: 0 [Endpoint 0] 13:52:25.174 SERIAL » [ACK] (0x06) 13:52:25.174 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[ProtectionCCReport] local: Unprotected rf: Unprotected 13:52:25.175 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.175 DRIVER send thread state: idle 13:52:25.175 CNTRLR « [Node 006] received protection status: local: Unprotected rf Unprotected 13:52:25.175 CNTRLR [Node 006] [+] [Protection] interviewComplete: true [Endpoint 0] [internal] 13:52:25.196 CNTRLR [Node 006] AssociationCC: doing a complete interview... 13:52:25.196 CNTRLR » [Node 006] querying number of association groups... 13:52:25.197 DRIVER Send queue: (2 messages) · [REQ] SendData (AssociationCCSupportedGroupingsGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.199 SERIAL » 0x010900130602850525e0a4 (11 bytes) 13:52:25.199 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 224 └─[AssociationCCSupportedGroupingsGet] 13:52:25.199 DRIVER send thread state: sending.execute 13:52:25.200 SERIAL « [ACK] (0x06) 13:52:25.201 DRIVER send thread state: sending.execute 13:52:25.207 SERIAL « 0x0104011301e8 (6 bytes) 13:52:25.207 SERIAL » [ACK] (0x06) 13:52:25.207 DRIVER « [RES] [SendData] was sent: true 13:52:25.208 DRIVER send thread state: sending.execute 13:52:25.223 SERIAL « 0x01070013e000000209 (9 bytes) 13:52:25.223 SERIAL » [ACK] (0x06) 13:52:25.223 DRIVER « [REQ] [SendData] callback id: 224 transmit status: OK 13:52:25.224 DRIVER send thread state: sending.execute 13:52:25.224 DRIVER send thread state: sending.waitForUpdate 13:52:25.234 SERIAL « 0x0109000400060385060571 (11 bytes) 13:52:25.235 CNTRLR [Node 006] [+] [Association] groupCount: 5 [Endpoint 0] [internal] 13:52:25.235 SERIAL » [ACK] (0x06) 13:52:25.236 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationCCSupportedGroupingsReport] group count: 5 13:52:25.236 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.236 DRIVER send thread state: idle 13:52:25.236 CNTRLR « [Node 006] supports 5 association groups 13:52:25.236 CNTRLR [Node 006] AssociationCC: skipping remaining interview because Multi Channel A ssociation is supported... 13:52:25.236 CNTRLR [Node 006] [+] [Association] interviewComplete: true [Endpoint 0] [internal] 13:52:25.236 CNTRLR [Node 006] MultiChannelAssociationCC: doing a complete interview... 13:52:25.236 CNTRLR » [Node 006] querying number of multi channel association groups... 13:52:25.237 DRIVER Send queue: (2 messages) · [REQ] SendData (MultiChannelAssociationCCSupportedGroupingsGet) [Node 6, awa ke] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.238 SERIAL » 0x0109001306028e0525e1ae (11 bytes) 13:52:25.238 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 225 └─[MultiChannelAssociationCCSupportedGroupingsGet] 13:52:25.238 DRIVER send thread state: sending.execute 13:52:25.239 SERIAL « [ACK] (0x06) 13:52:25.240 DRIVER send thread state: sending.execute 13:52:25.246 SERIAL « 0x0104011301e8 (6 bytes) 13:52:25.246 SERIAL » [ACK] (0x06) 13:52:25.246 DRIVER « [RES] [SendData] was sent: true 13:52:25.246 DRIVER send thread state: sending.execute 13:52:25.262 SERIAL « 0x01070013e100000208 (9 bytes) 13:52:25.262 SERIAL » [ACK] (0x06) 13:52:25.262 DRIVER « [REQ] [SendData] callback id: 225 transmit status: OK 13:52:25.263 DRIVER send thread state: sending.execute 13:52:25.263 DRIVER send thread state: sending.waitForUpdate 13:52:25.273 SERIAL « 0x010900040006038e06057a (11 bytes) 13:52:25.274 CNTRLR [Node 006] [+] [Multi Channel Association] groupCount: [Endpoint 0] [internal] 5 13:52:25.274 SERIAL » [ACK] (0x06) 13:52:25.274 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCSupportedGroupingsReport] group count: 5 13:52:25.274 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.275 DRIVER send thread state: idle 13:52:25.275 CNTRLR « [Node 006] supports 5 multi channel association groups 13:52:25.275 CNTRLR » [Node 006] querying multi channel association group #1... 13:52:25.275 DRIVER Send queue: (2 messages) · [REQ] SendData (MultiChannelAssociationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.276 SERIAL » 0x010a001306038e020125e2a9 (12 bytes) 13:52:25.277 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 226 └─[MultiChannelAssociationCCGet] group id: 1 13:52:25.277 DRIVER send thread state: sending.execute 13:52:25.278 SERIAL « [ACK] (0x06) 13:52:25.278 DRIVER send thread state: sending.execute 13:52:25.284 SERIAL « 0x0104011301e8 (6 bytes) 13:52:25.284 SERIAL » [ACK] (0x06) 13:52:25.285 DRIVER « [RES] [SendData] was sent: true 13:52:25.285 DRIVER send thread state: sending.execute 13:52:25.301 SERIAL « 0x01070013e20000020b (9 bytes) 13:52:25.301 SERIAL » [ACK] (0x06) 13:52:25.301 DRIVER « [REQ] [SendData] callback id: 226 transmit status: OK 13:52:25.302 DRIVER send thread state: sending.execute 13:52:25.302 DRIVER send thread state: sending.waitForUpdate 13:52:25.313 SERIAL « 0x010e00040006088e0301010000010176 (16 bytes) 13:52:25.314 SERIAL » [ACK] (0x06) 13:52:25.315 CNTRLR [Node 006] [+] [Multi Channel Association] maxNodes[1]: 1 13:52:25.315 CNTRLR [Node 006] [+] [Multi Channel Association] nodeIds[1]: 13:52:25.316 CNTRLR [Node 006] [+] [Multi Channel Association] endpoints[1]: [object Object] 13:52:25.316 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 1 maximum # of nodes: 1 node ids: endpoints: 1:1 13:52:25.317 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.318 DRIVER send thread state: idle 13:52:25.318 CNTRLR « [Node 006] received information for multi channel association group #1: maximum # of nodes: 1 currently assigned nodes: currently assigned endpoints: 1:1 13:52:25.319 CNTRLR » [Node 006] querying multi channel association group #2... 13:52:25.320 DRIVER Send queue: (2 messages) · [REQ] SendData (MultiChannelAssociationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.323 SERIAL » 0x010a001306038e020225e3ab (12 bytes) 13:52:25.323 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 227 └─[MultiChannelAssociationCCGet] group id: 2 13:52:25.323 DRIVER send thread state: sending.execute 13:52:25.325 SERIAL « [ACK] (0x06) 13:52:25.327 DRIVER send thread state: sending.execute 13:52:25.331 SERIAL « 0x0104011301e8 (6 bytes) 13:52:25.332 SERIAL » [ACK] (0x06) 13:52:25.332 DRIVER « [RES] [SendData] was sent: true 13:52:25.334 DRIVER send thread state: sending.execute 13:52:25.347 SERIAL « 0x01070013e30000020a (9 bytes) 13:52:25.348 SERIAL » [ACK] (0x06) 13:52:25.348 DRIVER « [REQ] [SendData] callback id: 227 transmit status: OK 13:52:25.350 DRIVER send thread state: sending.execute 13:52:25.350 DRIVER send thread state: sending.waitForUpdate 13:52:25.359 SERIAL « 0x010b00040006058e0302050079 (13 bytes) 13:52:25.359 SERIAL » [ACK] (0x06) 13:52:25.360 CNTRLR [Node 006] [+] [Multi Channel Association] maxNodes[2]: 5 13:52:25.360 CNTRLR [Node 006] [+] [Multi Channel Association] nodeIds[2]: 13:52:25.361 CNTRLR [Node 006] [+] [Multi Channel Association] endpoints[2]: 13:52:25.361 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 2 maximum # of nodes: 5 node ids: endpoints: 13:52:25.362 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.362 DRIVER send thread state: idle 13:52:25.363 CNTRLR « [Node 006] received information for multi channel association group #2: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 13:52:25.363 CNTRLR » [Node 006] querying multi channel association group #3... 13:52:25.365 DRIVER Send queue: (2 messages) · [REQ] SendData (MultiChannelAssociationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.367 SERIAL » 0x010a001306038e020325e4ad (12 bytes) 13:52:25.368 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 228 └─[MultiChannelAssociationCCGet] group id: 3 13:52:25.368 DRIVER send thread state: sending.execute 13:52:25.370 SERIAL « [ACK] (0x06) 13:52:25.370 DRIVER send thread state: sending.execute 13:52:25.376 SERIAL « 0x0104011301e8 (6 bytes) 13:52:25.376 SERIAL » [ACK] (0x06) 13:52:25.377 DRIVER « [RES] [SendData] was sent: true 13:52:25.378 DRIVER send thread state: sending.execute 13:52:25.401 SERIAL « 0x01070013e40000020d (9 bytes) 13:52:25.402 SERIAL » [ACK] (0x06) 13:52:25.403 DRIVER « [REQ] [SendData] callback id: 228 transmit status: OK 13:52:25.404 DRIVER send thread state: sending.execute 13:52:25.404 DRIVER send thread state: sending.waitForUpdate 13:52:25.405 SERIAL « 0x010b00040006058e0303050078 (13 bytes) 13:52:25.405 SERIAL » [ACK] (0x06) 13:52:25.406 CNTRLR [Node 006] [+] [Multi Channel Association] maxNodes[3]: 5 13:52:25.406 CNTRLR [Node 006] [+] [Multi Channel Association] nodeIds[3]: 13:52:25.406 CNTRLR [Node 006] [+] [Multi Channel Association] endpoints[3]: 13:52:25.407 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 3 maximum # of nodes: 5 node ids: endpoints: 13:52:25.407 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.407 DRIVER send thread state: idle 13:52:25.408 CNTRLR « [Node 006] received information for multi channel association group #3: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 13:52:25.408 CNTRLR » [Node 006] querying multi channel association group #4... 13:52:25.409 DRIVER Send queue: (2 messages) · [REQ] SendData (MultiChannelAssociationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.410 SERIAL » 0x010a001306038e020425e5ab (12 bytes) 13:52:25.410 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 229 └─[MultiChannelAssociationCCGet] group id: 4 13:52:25.410 DRIVER send thread state: sending.execute 13:52:25.412 SERIAL « [ACK] (0x06) 13:52:25.412 DRIVER send thread state: sending.execute 13:52:25.418 SERIAL « 0x0104011301e8 (6 bytes) 13:52:25.418 SERIAL » [ACK] (0x06) 13:52:25.418 DRIVER « [RES] [SendData] was sent: true 13:52:25.419 DRIVER send thread state: sending.execute 13:52:25.461 SERIAL « 0x01070013e50000050b (9 bytes) 13:52:25.462 SERIAL » [ACK] (0x06) 13:52:25.462 DRIVER « [REQ] [SendData] callback id: 229 transmit status: OK 13:52:25.464 DRIVER send thread state: sending.execute 13:52:25.465 DRIVER send thread state: sending.waitForUpdate 13:52:25.471 SERIAL « 0x010b00040006058e030405007f (13 bytes) 13:52:25.472 SERIAL » [ACK] (0x06) 13:52:25.473 CNTRLR [Node 006] [+] [Multi Channel Association] maxNodes[4]: 5 13:52:25.473 CNTRLR [Node 006] [+] [Multi Channel Association] nodeIds[4]: 13:52:25.474 CNTRLR [Node 006] [+] [Multi Channel Association] endpoints[4]: 13:52:25.474 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 4 maximum # of nodes: 5 node ids: endpoints: 13:52:25.478 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.478 DRIVER send thread state: idle 13:52:25.479 CNTRLR « [Node 006] received information for multi channel association group #4: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 13:52:25.479 CNTRLR » [Node 006] querying multi channel association group #5... 13:52:25.480 DRIVER Send queue: (2 messages) · [REQ] SendData (MultiChannelAssociationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.483 SERIAL » 0x010a001306038e020525e6a9 (12 bytes) 13:52:25.483 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 230 └─[MultiChannelAssociationCCGet] group id: 5 13:52:25.483 DRIVER send thread state: sending.execute 13:52:25.485 SERIAL « [ACK] (0x06) 13:52:25.486 DRIVER send thread state: sending.execute 13:52:25.491 SERIAL « 0x0104011301e8 (6 bytes) 13:52:25.492 SERIAL » [ACK] (0x06) 13:52:25.492 DRIVER « [RES] [SendData] was sent: true 13:52:25.493 DRIVER send thread state: sending.execute 13:52:25.506 SERIAL « 0x010c0004003606310504220410c1 (14 bytes) 13:52:25.507 CNTRLR [Node 054] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 13:52:25.508 CNTRLR [Node 054] [~] [Multilevel Sensor] Power: 207.2 => 104 [Endpoint 0] 13:52:25.508 SERIAL » [ACK] (0x06) 13:52:25.509 DRIVER « [Node 054] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 104 13:52:25.510 DRIVER send thread state: sending.execute 13:52:25.510 DRIVER send thread state: sending.execute 13:52:25.525 SERIAL « 0x01070013e60000030e (9 bytes) 13:52:25.525 SERIAL » [ACK] (0x06) 13:52:25.526 DRIVER « [REQ] [SendData] callback id: 230 transmit status: OK 13:52:25.527 DRIVER send thread state: sending.execute 13:52:25.528 DRIVER send thread state: sending.waitForUpdate 13:52:25.600 SERIAL « 0x010b00040006058e030505007e (13 bytes) 13:52:25.601 SERIAL » [ACK] (0x06) 13:52:25.601 CNTRLR [Node 006] [+] [Multi Channel Association] maxNodes[5]: 5 13:52:25.602 CNTRLR [Node 006] [+] [Multi Channel Association] nodeIds[5]: 13:52:25.602 CNTRLR [Node 006] [+] [Multi Channel Association] endpoints[5]: 13:52:25.603 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 5 maximum # of nodes: 5 node ids: endpoints: 13:52:25.604 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.604 DRIVER send thread state: idle 13:52:25.604 CNTRLR « [Node 006] received information for multi channel association group #5: maximum # of nodes: 5 currently assigned nodes: currently assigned endpoints: 13:52:25.605 CNTRLR » [Node 006] Lifeline group #1: assigning controller with multi channel associat ion... 13:52:25.607 DRIVER Send queue: (2 messages) · [REQ] SendData (MultiChannelAssociationCCSet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.610 SERIAL » 0x010d001306068e010100010025e7ac (15 bytes) 13:52:25.610 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 231 └─[MultiChannelAssociationCCSet] group id: 1 node ids: endpoints: 1:0 13:52:25.610 DRIVER send thread state: sending.execute 13:52:25.612 SERIAL « [ACK] (0x06) 13:52:25.613 DRIVER send thread state: sending.execute 13:52:25.619 SERIAL « 0x0104011301e8 (6 bytes) 13:52:25.619 SERIAL » [ACK] (0x06) 13:52:25.620 DRIVER « [RES] [SendData] was sent: true 13:52:25.621 DRIVER send thread state: sending.execute 13:52:25.631 SERIAL « 0x010b00040006058e030505007e (13 bytes) 13:52:25.632 SERIAL » [ACK] (0x06) 13:52:25.633 CNTRLR [Node 006] [~] [Multi Channel Association] maxNodes[5]: 5 => 5 13:52:25.633 CNTRLR [Node 006] [~] [Multi Channel Association] nodeIds[5]: => 13:52:25.634 CNTRLR [Node 006] [~] [Multi Channel Association] endpoints[5]: => 13:52:25.634 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 5 maximum # of nodes: 5 node ids: endpoints: 13:52:25.635 DRIVER send thread state: sending.execute 13:52:25.635 DRIVER send thread state: sending.execute 13:52:25.698 SERIAL « 0x01070013e700000905 (9 bytes) 13:52:25.699 SERIAL » [ACK] (0x06) 13:52:25.699 DRIVER « [REQ] [SendData] callback id: 231 transmit status: OK 13:52:25.701 DRIVER send thread state: sending.execute 13:52:25.701 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.701 DRIVER send thread state: idle 13:52:25.703 DRIVER Send queue: (2 messages) · [REQ] SendData (MultiChannelAssociationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.705 SERIAL » 0x010a001306038e020125e8a3 (12 bytes) 13:52:25.705 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 232 └─[MultiChannelAssociationCCGet] group id: 1 13:52:25.705 DRIVER send thread state: sending.execute 13:52:25.707 SERIAL « [ACK] (0x06) 13:52:25.708 DRIVER send thread state: sending.execute 13:52:25.714 SERIAL « 0x0104011301e8 (6 bytes) 13:52:25.714 SERIAL » [ACK] (0x06) 13:52:25.715 DRIVER « [RES] [SendData] was sent: true 13:52:25.716 DRIVER send thread state: sending.execute 13:52:25.730 SERIAL « 0x01070013e800000201 (9 bytes) 13:52:25.730 SERIAL » [ACK] (0x06) 13:52:25.731 DRIVER « [REQ] [SendData] callback id: 232 transmit status: OK 13:52:25.732 DRIVER send thread state: sending.execute 13:52:25.733 DRIVER send thread state: sending.waitForUpdate 13:52:25.775 SERIAL « 0x010b00040006058e030505007e (13 bytes) 13:52:25.776 SERIAL » [ACK] (0x06) 13:52:25.776 CNTRLR [Node 006] [~] [Multi Channel Association] maxNodes[5]: 5 => 5 13:52:25.777 CNTRLR [Node 006] [~] [Multi Channel Association] nodeIds[5]: => 13:52:25.777 CNTRLR [Node 006] [~] [Multi Channel Association] endpoints[5]: => 13:52:25.777 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MultiChannelAssociationCCReport] group id: 5 maximum # of nodes: 5 node ids: endpoints: 13:52:25.778 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.779 DRIVER send thread state: idle 13:52:25.779 CNTRLR [Node 006] Lifeline group #1: Multi Channel Association assignment failed, fal ling back to Association CC 13:52:25.781 DRIVER Send queue: (2 messages) · [REQ] SendData (AssociationCCSet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.784 SERIAL » 0x010b001306048501010125e9ad (13 bytes) 13:52:25.784 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 233 └─[AssociationCCSet] group id: 1 node ids: 1 13:52:25.784 DRIVER send thread state: sending.execute 13:52:25.786 SERIAL « [ACK] (0x06) 13:52:25.787 DRIVER send thread state: sending.execute 13:52:25.792 SERIAL « 0x0104011301e8 (6 bytes) 13:52:25.792 SERIAL » [ACK] (0x06) 13:52:25.793 DRIVER « [RES] [SendData] was sent: true 13:52:25.793 DRIVER send thread state: sending.execute 13:52:25.817 SERIAL « 0x01070013e900000301 (9 bytes) 13:52:25.817 SERIAL » [ACK] (0x06) 13:52:25.817 DRIVER « [REQ] [SendData] callback id: 233 transmit status: OK 13:52:25.818 DRIVER send thread state: sending.execute 13:52:25.818 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.818 DRIVER send thread state: idle 13:52:25.819 DRIVER Send queue: (2 messages) · [REQ] SendData (AssociationCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.820 SERIAL » 0x010a0013060385020125eaaa (12 bytes) 13:52:25.820 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 234 └─[AssociationCCGet] group id: 1 13:52:25.820 DRIVER send thread state: sending.execute 13:52:25.821 SERIAL « [ACK] (0x06) 13:52:25.821 DRIVER send thread state: sending.execute 13:52:25.828 SERIAL « 0x0104011301e8 (6 bytes) 13:52:25.828 SERIAL » [ACK] (0x06) 13:52:25.828 DRIVER « [RES] [SendData] was sent: true 13:52:25.828 DRIVER send thread state: sending.execute 13:52:25.844 SERIAL « 0x01070013ea00000203 (9 bytes) 13:52:25.844 SERIAL » [ACK] (0x06) 13:52:25.844 DRIVER « [REQ] [SendData] callback id: 234 transmit status: OK 13:52:25.845 DRIVER send thread state: sending.execute 13:52:25.845 DRIVER send thread state: sending.waitForUpdate 13:52:25.855 SERIAL « 0x010b0004000605850301010075 (13 bytes) 13:52:25.856 SERIAL » [ACK] (0x06) 13:52:25.856 CNTRLR [Node 006] [+] [Association] maxNodes[1]: 1 [internal] 13:52:25.856 CNTRLR [Node 006] [+] [Association] nodeIds[1]: [internal] 13:52:25.856 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationCCReport] group id: 1 max # of nodes: 1 node IDs: reports to follow: 0 13:52:25.857 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.857 DRIVER send thread state: idle 13:52:25.857 CNTRLR [Node 006] [+] [Association] hasLifeline: true [internal] 13:52:25.857 CNTRLR [Node 006] [+] [Multi Channel Association] interviewCo [Endpoint 0] [internal] mplete: true 13:52:25.863 CNTRLR [Node 006] AssociationGroupInfoCC: doing a complete interview... 13:52:25.863 CNTRLR » [Node 006] Association group #1: Querying name... 13:52:25.864 DRIVER Send queue: (2 messages) · [REQ] SendData (AssociationGroupInfoCCNameGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.865 SERIAL » 0x010a0013060359010125eb74 (12 bytes) 13:52:25.865 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 235 └─[AssociationGroupInfoCCNameGet] group id: 1 13:52:25.865 DRIVER send thread state: sending.execute 13:52:25.866 SERIAL « [ACK] (0x06) 13:52:25.867 DRIVER send thread state: sending.execute 13:52:25.873 SERIAL « 0x0104011301e8 (6 bytes) 13:52:25.873 SERIAL » [ACK] (0x06) 13:52:25.873 DRIVER « [RES] [SendData] was sent: true 13:52:25.874 DRIVER send thread state: sending.execute 13:52:25.889 SERIAL « 0x01070013eb00000202 (9 bytes) 13:52:25.889 SERIAL » [ACK] (0x06) 13:52:25.889 DRIVER « [REQ] [SendData] callback id: 235 transmit status: OK 13:52:25.890 DRIVER send thread state: sending.execute 13:52:25.890 DRIVER send thread state: sending.waitForUpdate 13:52:25.902 SERIAL « 0x0112000400060c590201084c6966656c696e6599 (20 bytes) 13:52:25.902 CNTRLR [Node 006] [+] [Association Group Information] name[1]: "Lifeline" [internal] 13:52:25.902 SERIAL » [ACK] (0x06) 13:52:25.902 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 1 name: Lifeline 13:52:25.903 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.903 DRIVER send thread state: idle 13:52:25.903 CNTRLR « [Node 006] Association group #1 has name "Lifeline" 13:52:25.903 CNTRLR » [Node 006] Association group #1: Querying info... 13:52:25.904 DRIVER Send queue: (2 messages) · [REQ] SendData (AssociationGroupInfoCCInfoGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.905 SERIAL » 0x010b001306045903000125ec77 (13 bytes) 13:52:25.905 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 236 └─[AssociationGroupInfoCCInfoGet] group id: 1 refresh cache: false 13:52:25.905 DRIVER send thread state: sending.execute 13:52:25.906 SERIAL « [ACK] (0x06) 13:52:25.907 DRIVER send thread state: sending.execute 13:52:25.913 SERIAL « 0x0104011301e8 (6 bytes) 13:52:25.913 SERIAL » [ACK] (0x06) 13:52:25.914 DRIVER « [RES] [SendData] was sent: true 13:52:25.915 DRIVER send thread state: sending.execute 13:52:25.929 SERIAL « 0x01070013ec00000205 (9 bytes) 13:52:25.930 SERIAL » [ACK] (0x06) 13:52:25.930 DRIVER « [REQ] [SendData] callback id: 236 transmit status: OK 13:52:25.932 DRIVER send thread state: sending.execute 13:52:25.932 DRIVER send thread state: sending.waitForUpdate 13:52:25.942 SERIAL « 0x0110000400060a59040101000001000000bb (18 bytes) 13:52:25.943 CNTRLR [Node 006] [+] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false 13:52:25.944 CNTRLR [Node 006] [+] [Association Group Information] info[1]: [object Obj [internal] ect] 13:52:25.944 SERIAL » [ACK] (0x06) 13:52:25.945 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #1 mode: 0 profile: 1 event code: 0 13:52:25.946 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.946 DRIVER send thread state: idle 13:52:25.946 CNTRLR « [Node 006] Received info for association group #1: info is dynamic: false profile: General: Lifeline 13:52:25.946 CNTRLR » [Node 006] Association group #1: Querying command list... 13:52:25.948 DRIVER Send queue: (2 messages) · [REQ] SendData (AssociationGroupInfoCCCommandListGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.951 SERIAL » 0x010b001306045905800125edf0 (13 bytes) 13:52:25.952 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 237 └─[AssociationGroupInfoCCCommandListGet] group id: 1 allow cache: true 13:52:25.952 DRIVER send thread state: sending.execute 13:52:25.954 SERIAL « [ACK] (0x06) 13:52:25.955 DRIVER send thread state: sending.execute 13:52:25.960 SERIAL « 0x0104011301e8 (6 bytes) 13:52:25.961 SERIAL » [ACK] (0x06) 13:52:25.961 DRIVER « [RES] [SendData] was sent: true 13:52:25.962 DRIVER send thread state: sending.execute 13:52:25.976 SERIAL « 0x01070013ed00000305 (9 bytes) 13:52:25.977 SERIAL » [ACK] (0x06) 13:52:25.977 DRIVER « [REQ] [SendData] callback id: 237 transmit status: OK 13:52:25.979 DRIVER send thread state: sending.execute 13:52:25.979 DRIVER send thread state: sending.waitForUpdate 13:52:25.989 SERIAL « 0x0114000400060e5906010a25035a0132025b037105d2 (22 bytes) 13:52:25.991 CNTRLR [Node 006] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[1]: [object Map] 13:52:25.991 SERIAL » [ACK] (0x06) 13:52:25.992 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 1 commands: · Binary Switch: 0x03 · Device Reset Locally: 0x01 · Meter: 0x02 · Central Scene: 0x03 · Notification: 0x05 13:52:25.993 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.994 DRIVER send thread state: idle 13:52:25.994 CNTRLR » [Node 006] Association group #2: Querying name... 13:52:25.996 DRIVER Send queue: (2 messages) · [REQ] SendData (AssociationGroupInfoCCNameGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:25.998 SERIAL » 0x010a0013060359010225ee72 (12 bytes) 13:52:25.999 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 238 └─[AssociationGroupInfoCCNameGet] group id: 2 13:52:25.999 DRIVER send thread state: sending.execute 13:52:26.000 SERIAL « [ACK] (0x06) 13:52:26.001 DRIVER send thread state: sending.execute 13:52:26.007 SERIAL « 0x0104011301e8 (6 bytes) 13:52:26.007 SERIAL » [ACK] (0x06) 13:52:26.008 DRIVER « [RES] [SendData] was sent: true 13:52:26.009 DRIVER send thread state: sending.execute 13:52:26.023 SERIAL « 0x01070013ee00000207 (9 bytes) 13:52:26.023 SERIAL » [ACK] (0x06) 13:52:26.024 DRIVER « [REQ] [SendData] callback id: 238 transmit status: OK 13:52:26.025 DRIVER send thread state: sending.execute 13:52:26.026 DRIVER send thread state: sending.waitForUpdate 13:52:26.036 SERIAL « 0x0114000400060e5902020a4f6e2f4f66662853312996 (22 bytes) 13:52:26.037 CNTRLR [Node 006] [+] [Association Group Information] name[2]: "On/Off(S1) [internal] " 13:52:26.037 SERIAL » [ACK] (0x06) 13:52:26.038 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 2 name: On/Off(S1) 13:52:26.039 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.039 DRIVER send thread state: idle 13:52:26.039 CNTRLR « [Node 006] Association group #2 has name "On/Off(S1)" 13:52:26.039 CNTRLR » [Node 006] Association group #2: Querying info... 13:52:26.041 DRIVER Send queue: (2 messages) · [REQ] SendData (AssociationGroupInfoCCInfoGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.044 SERIAL » 0x010b001306045903000225ef77 (13 bytes) 13:52:26.044 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 239 └─[AssociationGroupInfoCCInfoGet] group id: 2 refresh cache: false 13:52:26.044 DRIVER send thread state: sending.execute 13:52:26.046 SERIAL « [ACK] (0x06) 13:52:26.047 DRIVER send thread state: sending.execute 13:52:26.053 SERIAL « 0x0104011301e8 (6 bytes) 13:52:26.053 SERIAL » [ACK] (0x06) 13:52:26.053 DRIVER « [RES] [SendData] was sent: true 13:52:26.055 DRIVER send thread state: sending.execute 13:52:26.069 SERIAL « 0x01070013ef00000206 (9 bytes) 13:52:26.069 SERIAL » [ACK] (0x06) 13:52:26.070 DRIVER « [REQ] [SendData] callback id: 239 transmit status: OK 13:52:26.071 DRIVER send thread state: sending.execute 13:52:26.072 DRIVER send thread state: sending.waitForUpdate 13:52:26.081 SERIAL « 0x0110000400060a5904010200200100000098 (18 bytes) 13:52:26.082 CNTRLR [Node 006] [~] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false => false 13:52:26.082 CNTRLR [Node 006] [+] [Association Group Information] info[2]: [object Obj [internal] ect] 13:52:26.083 SERIAL » [ACK] (0x06) 13:52:26.083 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #2 mode: 0 profile: 8193 event code: 0 13:52:26.084 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.084 DRIVER send thread state: idle 13:52:26.085 CNTRLR « [Node 006] Received info for association group #2: info is dynamic: false profile: Control: Key 01 13:52:26.085 CNTRLR » [Node 006] Association group #2: Querying command list... 13:52:26.086 DRIVER Send queue: (2 messages) · [REQ] SendData (AssociationGroupInfoCCCommandListGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.089 SERIAL » 0x010b001306045905800225f0ee (13 bytes) 13:52:26.089 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 240 └─[AssociationGroupInfoCCCommandListGet] group id: 2 allow cache: true 13:52:26.090 DRIVER send thread state: sending.execute 13:52:26.091 SERIAL « [ACK] (0x06) 13:52:26.092 DRIVER send thread state: sending.execute 13:52:26.098 SERIAL « 0x0104011301e8 (6 bytes) 13:52:26.098 SERIAL » [ACK] (0x06) 13:52:26.098 DRIVER « [RES] [SendData] was sent: true 13:52:26.104 DRIVER send thread state: sending.execute 13:52:26.114 SERIAL « 0x01070013f000000219 (9 bytes) 13:52:26.114 SERIAL » [ACK] (0x06) 13:52:26.115 DRIVER « [REQ] [SendData] callback id: 240 transmit status: OK 13:52:26.116 DRIVER send thread state: sending.execute 13:52:26.117 DRIVER send thread state: sending.waitForUpdate 13:52:26.124 SERIAL « 0x010c000400060659060202200189 (14 bytes) 13:52:26.125 CNTRLR [Node 006] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[2]: [object Map] 13:52:26.125 SERIAL » [ACK] (0x06) 13:52:26.126 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 2 commands: · Basic: 0x01 13:52:26.127 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.127 DRIVER send thread state: idle 13:52:26.127 CNTRLR » [Node 006] Association group #3: Querying name... 13:52:26.129 DRIVER Send queue: (2 messages) · [REQ] SendData (AssociationGroupInfoCCNameGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.131 SERIAL » 0x010a0013060359010325f16c (12 bytes) 13:52:26.131 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 241 └─[AssociationGroupInfoCCNameGet] group id: 3 13:52:26.131 DRIVER send thread state: sending.execute 13:52:26.134 SERIAL « 0x0114000400100e3202213400000115000000000000c0 (22 bytes) 13:52:26.135 CNTRLR [Node 016] [~] [Meter] value[66049]: 27.7 => 27.7 [Endpoint 0] 13:52:26.135 CNTRLR [Node 016] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:52:26.135 SERIAL » [ACK] (0x06) 13:52:26.136 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 27.7 time delta: 0 seconds 13:52:26.137 DRIVER send thread state: sending.execute 13:52:26.137 DRIVER send thread state: sending.execute 13:52:26.137 SERIAL « [CAN] (0x18) 13:52:26.138 CNTRLR Failed to execute controller command after 1/3 attempts. Scheduling next try i n 100 ms. 13:52:26.138 DRIVER send thread state: sending.execute 13:52:26.239 SERIAL » 0x010a0013060359010325f16c (12 bytes) 13:52:26.240 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 241 └─[AssociationGroupInfoCCNameGet] group id: 3 13:52:26.242 SERIAL « [ACK] (0x06) 13:52:26.243 DRIVER send thread state: sending.execute 13:52:26.248 SERIAL « 0x0104011301e8 (6 bytes) 13:52:26.248 SERIAL » [ACK] (0x06) 13:52:26.249 DRIVER « [RES] [SendData] was sent: true 13:52:26.250 DRIVER send thread state: sending.execute 13:52:26.264 SERIAL « 0x01070013f100000218 (9 bytes) 13:52:26.265 SERIAL » [ACK] (0x06) 13:52:26.266 DRIVER « [REQ] [SendData] callback id: 241 transmit status: OK 13:52:26.268 DRIVER send thread state: sending.execute 13:52:26.268 DRIVER send thread state: sending.waitForUpdate 13:52:26.277 SERIAL « 0x0114000400060e5902030a44696d6d657228533129ec (22 bytes) 13:52:26.278 CNTRLR [Node 006] [+] [Association Group Information] name[3]: "Dimmer(S1) [internal] " 13:52:26.278 SERIAL » [ACK] (0x06) 13:52:26.278 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 3 name: Dimmer(S1) 13:52:26.279 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.279 DRIVER send thread state: idle 13:52:26.280 CNTRLR « [Node 006] Association group #3 has name "Dimmer(S1)" 13:52:26.280 CNTRLR » [Node 006] Association group #3: Querying info... 13:52:26.281 DRIVER Send queue: (2 messages) · [REQ] SendData (AssociationGroupInfoCCInfoGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.283 SERIAL » 0x010b001306045903000325f26b (13 bytes) 13:52:26.284 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 242 └─[AssociationGroupInfoCCInfoGet] group id: 3 refresh cache: false 13:52:26.284 DRIVER send thread state: sending.execute 13:52:26.286 SERIAL « [ACK] (0x06) 13:52:26.286 DRIVER send thread state: sending.execute 13:52:26.292 SERIAL « 0x0104011301e8 (6 bytes) 13:52:26.292 SERIAL » [ACK] (0x06) 13:52:26.293 DRIVER « [RES] [SendData] was sent: true 13:52:26.294 DRIVER send thread state: sending.execute 13:52:26.308 SERIAL « 0x01070013f20000021b (9 bytes) 13:52:26.309 SERIAL » [ACK] (0x06) 13:52:26.309 DRIVER « [REQ] [SendData] callback id: 242 transmit status: OK 13:52:26.311 DRIVER send thread state: sending.execute 13:52:26.311 DRIVER send thread state: sending.waitForUpdate 13:52:26.320 SERIAL « 0x0110000400060a5904010300200100000099 (18 bytes) 13:52:26.321 CNTRLR [Node 006] [~] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false => false 13:52:26.321 CNTRLR [Node 006] [+] [Association Group Information] info[3]: [object Obj [internal] ect] 13:52:26.322 SERIAL » [ACK] (0x06) 13:52:26.322 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #3 mode: 0 profile: 8193 event code: 0 13:52:26.323 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.323 DRIVER send thread state: idle 13:52:26.323 CNTRLR « [Node 006] Received info for association group #3: info is dynamic: false profile: Control: Key 01 13:52:26.324 CNTRLR » [Node 006] Association group #3: Querying command list... 13:52:26.325 DRIVER Send queue: (2 messages) · [REQ] SendData (AssociationGroupInfoCCCommandListGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.327 SERIAL » 0x010b001306045905800325f3ec (13 bytes) 13:52:26.328 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 243 └─[AssociationGroupInfoCCCommandListGet] group id: 3 allow cache: true 13:52:26.328 DRIVER send thread state: sending.execute 13:52:26.329 SERIAL « [ACK] (0x06) 13:52:26.330 DRIVER send thread state: sending.execute 13:52:26.336 SERIAL « 0x0104011301e8 (6 bytes) 13:52:26.336 SERIAL » [ACK] (0x06) 13:52:26.336 DRIVER « [RES] [SendData] was sent: true 13:52:26.337 DRIVER send thread state: sending.execute 13:52:26.352 SERIAL « 0x01070013f30000021a (9 bytes) 13:52:26.353 SERIAL » [ACK] (0x06) 13:52:26.353 DRIVER « [REQ] [SendData] callback id: 243 transmit status: OK 13:52:26.355 DRIVER send thread state: sending.execute 13:52:26.355 DRIVER send thread state: sending.waitForUpdate 13:52:26.364 SERIAL « 0x0110000400060a590603062601260426059b (18 bytes) 13:52:26.365 CNTRLR [Node 006] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[3]: [object Map] 13:52:26.365 SERIAL » [ACK] (0x06) 13:52:26.366 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 3 commands: · Multilevel Switch: 0x01, 0x04, 0x05 13:52:26.367 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.367 DRIVER send thread state: idle 13:52:26.367 CNTRLR » [Node 006] Association group #4: Querying name... 13:52:26.369 DRIVER Send queue: (2 messages) · [REQ] SendData (AssociationGroupInfoCCNameGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.371 SERIAL » 0x010a0013060359010425f46e (12 bytes) 13:52:26.371 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 244 └─[AssociationGroupInfoCCNameGet] group id: 4 13:52:26.372 DRIVER send thread state: sending.execute 13:52:26.373 SERIAL « [ACK] (0x06) 13:52:26.374 DRIVER send thread state: sending.execute 13:52:26.380 SERIAL « 0x0104011301e8 (6 bytes) 13:52:26.380 SERIAL » [ACK] (0x06) 13:52:26.381 DRIVER « [RES] [SendData] was sent: true 13:52:26.382 DRIVER send thread state: sending.execute 13:52:26.389 SERIAL « 0x01140004000f0e320221340000012e000000000000e4 (22 bytes) 13:52:26.390 CNTRLR [Node 015] [~] [Meter] value[66049]: 28.3 => 30.2 [Endpoint 0] 13:52:26.390 CNTRLR [Node 015] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:52:26.391 SERIAL » [ACK] (0x06) 13:52:26.391 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 30.2 time delta: 0 seconds 13:52:26.392 DRIVER send thread state: sending.execute 13:52:26.393 DRIVER send thread state: sending.execute 13:52:26.409 SERIAL « 0x01070013f40000041b (9 bytes) 13:52:26.409 SERIAL » [ACK] (0x06) 13:52:26.410 DRIVER « [REQ] [SendData] callback id: 244 transmit status: OK 13:52:26.411 DRIVER send thread state: sending.execute 13:52:26.411 DRIVER send thread state: sending.waitForUpdate 13:52:26.422 SERIAL « 0x0114000400060e5902040a4f6e2f4f66662853322993 (22 bytes) 13:52:26.422 CNTRLR [Node 006] [+] [Association Group Information] name[4]: "On/Off(S2) [internal] " 13:52:26.422 SERIAL » [ACK] (0x06) 13:52:26.423 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 4 name: On/Off(S2) 13:52:26.424 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.424 DRIVER send thread state: idle 13:52:26.424 CNTRLR « [Node 006] Association group #4 has name "On/Off(S2)" 13:52:26.424 CNTRLR » [Node 006] Association group #4: Querying info... 13:52:26.426 DRIVER Send queue: (2 messages) · [REQ] SendData (AssociationGroupInfoCCInfoGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.428 SERIAL » 0x010b001306045903000425f56b (13 bytes) 13:52:26.428 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 245 └─[AssociationGroupInfoCCInfoGet] group id: 4 refresh cache: false 13:52:26.428 DRIVER send thread state: sending.execute 13:52:26.430 SERIAL « [ACK] (0x06) 13:52:26.431 DRIVER send thread state: sending.execute 13:52:26.436 SERIAL « 0x0104011301e8 (6 bytes) 13:52:26.437 SERIAL » [ACK] (0x06) 13:52:26.437 DRIVER « [RES] [SendData] was sent: true 13:52:26.438 DRIVER send thread state: sending.execute 13:52:26.507 SERIAL « 0x010c00040036063105042204f322 (14 bytes) 13:52:26.508 CNTRLR [Node 054] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 13:52:26.509 CNTRLR [Node 054] [~] [Multilevel Sensor] Power: 104 => 126.7 [Endpoint 0] 13:52:26.509 SERIAL » [ACK] (0x06) 13:52:26.510 DRIVER « [Node 054] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 126.7 13:52:26.511 DRIVER send thread state: sending.execute 13:52:26.511 DRIVER send thread state: sending.execute 13:52:26.520 SERIAL « 0x01070013f500000917 (9 bytes) 13:52:26.520 SERIAL » [ACK] (0x06) 13:52:26.521 DRIVER « [REQ] [SendData] callback id: 245 transmit status: OK 13:52:26.522 DRIVER send thread state: sending.execute 13:52:26.522 DRIVER send thread state: sending.waitForUpdate 13:52:26.571 SERIAL « 0x0110000400060a590401040020020000009d (18 bytes) 13:52:26.572 CNTRLR [Node 006] [~] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false => false 13:52:26.572 CNTRLR [Node 006] [+] [Association Group Information] info[4]: [object Obj [internal] ect] 13:52:26.572 SERIAL » [ACK] (0x06) 13:52:26.572 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #4 mode: 0 profile: 8194 event code: 0 13:52:26.572 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.572 DRIVER send thread state: idle 13:52:26.572 CNTRLR « [Node 006] Received info for association group #4: info is dynamic: false profile: Control: Key 02 13:52:26.572 CNTRLR » [Node 006] Association group #4: Querying command list... 13:52:26.573 DRIVER Send queue: (2 messages) · [REQ] SendData (AssociationGroupInfoCCCommandListGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.574 SERIAL » 0x010b001306045905800425f6ee (13 bytes) 13:52:26.574 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 246 └─[AssociationGroupInfoCCCommandListGet] group id: 4 allow cache: true 13:52:26.574 DRIVER send thread state: sending.execute 13:52:26.575 SERIAL « [ACK] (0x06) 13:52:26.576 DRIVER send thread state: sending.execute 13:52:26.582 SERIAL « 0x0104011301e8 (6 bytes) 13:52:26.582 SERIAL » [ACK] (0x06) 13:52:26.582 DRIVER « [RES] [SendData] was sent: true 13:52:26.582 DRIVER send thread state: sending.execute 13:52:26.658 SERIAL « 0x0110000400060a590401040020020000009d (18 bytes) 13:52:26.658 CNTRLR [Node 006] [~] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false => false 13:52:26.658 CNTRLR [Node 006] [~] [Association Group Information] info[4]: [object Obj [internal] ect] => [object Object] 13:52:26.658 SERIAL » [ACK] (0x06) 13:52:26.658 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #4 mode: 0 profile: 8194 event code: 0 13:52:26.658 DRIVER send thread state: sending.execute 13:52:26.659 DRIVER send thread state: sending.execute 13:52:26.679 SERIAL « 0x01070013f600000a17 (9 bytes) 13:52:26.679 SERIAL » [ACK] (0x06) 13:52:26.679 DRIVER « [REQ] [SendData] callback id: 246 transmit status: OK 13:52:26.680 DRIVER send thread state: sending.execute 13:52:26.680 DRIVER send thread state: sending.waitForUpdate 13:52:26.690 SERIAL « 0x010c00040006065906040220018f (14 bytes) 13:52:26.691 CNTRLR [Node 006] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[4]: [object Map] 13:52:26.691 SERIAL » [ACK] (0x06) 13:52:26.691 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 4 commands: · Basic: 0x01 13:52:26.691 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.691 DRIVER send thread state: idle 13:52:26.691 CNTRLR » [Node 006] Association group #5: Querying name... 13:52:26.692 DRIVER Send queue: (2 messages) · [REQ] SendData (AssociationGroupInfoCCNameGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.693 SERIAL » 0x010a0013060359010525f76c (12 bytes) 13:52:26.693 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 247 └─[AssociationGroupInfoCCNameGet] group id: 5 13:52:26.693 DRIVER send thread state: sending.execute 13:52:26.694 SERIAL « [ACK] (0x06) 13:52:26.694 DRIVER send thread state: sending.execute 13:52:26.701 SERIAL « 0x0104011301e8 (6 bytes) 13:52:26.701 SERIAL » [ACK] (0x06) 13:52:26.701 DRIVER « [RES] [SendData] was sent: true 13:52:26.702 DRIVER send thread state: sending.execute 13:52:26.717 SERIAL « 0x01070013f70000021e (9 bytes) 13:52:26.717 SERIAL » [ACK] (0x06) 13:52:26.718 DRIVER « [REQ] [SendData] callback id: 247 transmit status: OK 13:52:26.719 DRIVER send thread state: sending.execute 13:52:26.719 DRIVER send thread state: sending.waitForUpdate 13:52:26.730 SERIAL « 0x0114000400060e5902050a44696d6d657228533229e9 (22 bytes) 13:52:26.730 CNTRLR [Node 006] [+] [Association Group Information] name[5]: "Dimmer(S2) [internal] " 13:52:26.730 SERIAL » [ACK] (0x06) 13:52:26.731 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCNameReport] group id: 5 name: Dimmer(S2) 13:52:26.732 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.732 DRIVER send thread state: idle 13:52:26.732 CNTRLR « [Node 006] Association group #5 has name "Dimmer(S2)" 13:52:26.732 CNTRLR » [Node 006] Association group #5: Querying info... 13:52:26.734 DRIVER Send queue: (2 messages) · [REQ] SendData (AssociationGroupInfoCCInfoGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.736 SERIAL » 0x010b001306045903000525f867 (13 bytes) 13:52:26.736 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 248 └─[AssociationGroupInfoCCInfoGet] group id: 5 refresh cache: false 13:52:26.737 DRIVER send thread state: sending.execute 13:52:26.738 SERIAL « [ACK] (0x06) 13:52:26.739 DRIVER send thread state: sending.execute 13:52:26.745 SERIAL « 0x0104011301e8 (6 bytes) 13:52:26.745 SERIAL » [ACK] (0x06) 13:52:26.745 DRIVER « [RES] [SendData] was sent: true 13:52:26.746 DRIVER send thread state: sending.execute 13:52:26.761 SERIAL « 0x01070013f800000211 (9 bytes) 13:52:26.761 SERIAL » [ACK] (0x06) 13:52:26.762 DRIVER « [REQ] [SendData] callback id: 248 transmit status: OK 13:52:26.763 DRIVER send thread state: sending.execute 13:52:26.763 DRIVER send thread state: sending.waitForUpdate 13:52:26.773 SERIAL « 0x0110000400060a590401050020020000009c (18 bytes) 13:52:26.774 CNTRLR [Node 006] [~] [Association Group Information] hasDyna [Endpoint 0] [internal] micInfo: false => false 13:52:26.774 CNTRLR [Node 006] [+] [Association Group Information] info[5]: [object Obj [internal] ect] 13:52:26.774 SERIAL » [ACK] (0x06) 13:52:26.775 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCInfoReport] is list mode: false has dynamic info: false groups: · Group #5 mode: 0 profile: 8194 event code: 0 13:52:26.776 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.776 DRIVER send thread state: idle 13:52:26.776 CNTRLR « [Node 006] Received info for association group #5: info is dynamic: false profile: Control: Key 02 13:52:26.776 CNTRLR » [Node 006] Association group #5: Querying command list... 13:52:26.778 DRIVER Send queue: (2 messages) · [REQ] SendData (AssociationGroupInfoCCCommandListGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.780 SERIAL » 0x010b001306045905800525f9e0 (13 bytes) 13:52:26.780 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 249 └─[AssociationGroupInfoCCCommandListGet] group id: 5 allow cache: true 13:52:26.780 DRIVER send thread state: sending.execute 13:52:26.782 SERIAL « [ACK] (0x06) 13:52:26.782 DRIVER send thread state: sending.execute 13:52:26.788 SERIAL « 0x0104011301e8 (6 bytes) 13:52:26.788 SERIAL » [ACK] (0x06) 13:52:26.789 DRIVER « [RES] [SendData] was sent: true 13:52:26.790 DRIVER send thread state: sending.execute 13:52:26.804 SERIAL « 0x01070013f900000210 (9 bytes) 13:52:26.805 SERIAL » [ACK] (0x06) 13:52:26.805 DRIVER « [REQ] [SendData] callback id: 249 transmit status: OK 13:52:26.806 DRIVER send thread state: sending.execute 13:52:26.807 DRIVER send thread state: sending.waitForUpdate 13:52:26.817 SERIAL « 0x0110000400060a590605062601260426059d (18 bytes) 13:52:26.817 CNTRLR [Node 006] [+] [Association Group Information] issuedC [Endpoint 0] [internal] ommands[5]: [object Map] 13:52:26.818 SERIAL » [ACK] (0x06) 13:52:26.818 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[AssociationGroupInfoCCCommandListReport] group id: 5 commands: · Multilevel Switch: 0x01, 0x04, 0x05 13:52:26.819 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.819 DRIVER send thread state: idle 13:52:26.819 CNTRLR [Node 006] [+] [Association Group Information] intervi [Endpoint 0] [internal] ewComplete: true 13:52:26.920 CNTRLR [Node 006] NotificationCC: doing a complete interview... 13:52:26.920 CNTRLR » [Node 006] querying supported notification types... 13:52:26.921 DRIVER Send queue: (2 messages) · [REQ] SendData (NotificationCCSupportedGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.923 SERIAL » 0x010900130602710725fa48 (11 bytes) 13:52:26.923 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 250 └─[NotificationCCSupportedGet] 13:52:26.924 DRIVER send thread state: sending.execute 13:52:26.926 SERIAL « [ACK] (0x06) 13:52:26.930 DRIVER send thread state: sending.execute 13:52:26.933 SERIAL « 0x0104011301e8 (6 bytes) 13:52:26.939 SERIAL » [ACK] (0x06) 13:52:26.940 DRIVER « [RES] [SendData] was sent: true 13:52:26.941 DRIVER send thread state: sending.execute 13:52:26.948 SERIAL « 0x01070013fa00000213 (9 bytes) 13:52:26.948 SERIAL » [ACK] (0x06) 13:52:26.948 DRIVER « [REQ] [SendData] callback id: 250 transmit status: OK 13:52:26.952 DRIVER send thread state: sending.execute 13:52:26.952 DRIVER send thread state: sending.waitForUpdate 13:52:26.959 SERIAL « 0x010b0004000605710802100199 (13 bytes) 13:52:26.960 CNTRLR [Node 006] [+] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" 13:52:26.960 CNTRLR [Node 006] [+] [Notification] supportedNotificationTyp [Endpoint 0] [internal] es: 4,8 13:52:26.961 CNTRLR [Node 006] [+] [Notification] supportsV1Alarm: false [Endpoint 0] [internal] 13:52:26.961 CNTRLR [Node 006] [~] [Notification] supportedNotificationTyp [Endpoint 0] [internal] es: 4,8 => 4,8 13:52:26.961 SERIAL » [ACK] (0x06) 13:52:26.961 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[NotificationCCSupportedReport] supports V1 alarm: false supported notification types: · Heat Alarm · Power Management 13:52:26.962 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.962 DRIVER send thread state: idle 13:52:26.962 CNTRLR « [Node 006] received supported notification types: · Heat Alarm · Power Management 13:52:26.962 CNTRLR » [Node 006] querying supported notification events for Heat Alarm... 13:52:26.963 DRIVER Send queue: (2 messages) · [REQ] SendData (NotificationCCEventSupportedGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:26.964 SERIAL » 0x010a0013060371010425fb49 (12 bytes) 13:52:26.964 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 251 └─[NotificationCCEventSupportedGet] notification type: Heat Alarm 13:52:26.964 DRIVER send thread state: sending.execute 13:52:26.965 SERIAL « [ACK] (0x06) 13:52:26.965 DRIVER send thread state: sending.execute 13:52:26.972 SERIAL « 0x0104011301e8 (6 bytes) 13:52:26.972 SERIAL » [ACK] (0x06) 13:52:26.972 DRIVER « [RES] [SendData] was sent: true 13:52:26.973 DRIVER send thread state: sending.execute 13:52:26.988 SERIAL « 0x01070013fb00000212 (9 bytes) 13:52:26.988 SERIAL » [ACK] (0x06) 13:52:26.988 DRIVER « [REQ] [SendData] callback id: 251 transmit status: OK 13:52:26.989 DRIVER send thread state: sending.execute 13:52:26.989 DRIVER send thread state: sending.waitForUpdate 13:52:26.999 SERIAL « 0x010b0004000605710204010481 (13 bytes) 13:52:27.000 CNTRLR [Node 006] [~] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" => "unknown" 13:52:27.000 CNTRLR [Node 006] [+] [Notification] supportedNotificationEvents[4]: 2 [internal] 13:52:27.000 CNTRLR [Node 006] [Notification] Heat Alarm[Heat sensor status]: metadat [Endpoint 0] a updated 13:52:27.001 SERIAL » [ACK] (0x06) 13:52:27.001 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[NotificationCCEventSupportedReport] notification type: Heat Alarm supported events: · Unknown (0x02) 13:52:27.001 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:27.002 DRIVER send thread state: idle 13:52:27.002 CNTRLR « [Node 006] received supported notification events for Heat Alarm: 2 13:52:27.002 CNTRLR » [Node 006] querying supported notification events for Power Management... 13:52:27.002 DRIVER Send queue: (2 messages) · [REQ] SendData (NotificationCCEventSupportedGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:27.003 SERIAL » 0x010a0013060371010825fc42 (12 bytes) 13:52:27.003 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 252 └─[NotificationCCEventSupportedGet] notification type: Power Management 13:52:27.003 DRIVER send thread state: sending.execute 13:52:27.005 SERIAL « [ACK] (0x06) 13:52:27.005 DRIVER send thread state: sending.execute 13:52:27.011 SERIAL « 0x0104011301e8 (6 bytes) 13:52:27.011 SERIAL » [ACK] (0x06) 13:52:27.011 DRIVER « [RES] [SendData] was sent: true 13:52:27.011 DRIVER send thread state: sending.execute 13:52:27.027 SERIAL « 0x01070013fc00000215 (9 bytes) 13:52:27.027 SERIAL » [ACK] (0x06) 13:52:27.027 DRIVER « [REQ] [SendData] callback id: 252 transmit status: OK 13:52:27.028 DRIVER send thread state: sending.execute 13:52:27.029 DRIVER send thread state: sending.waitForUpdate 13:52:27.039 SERIAL « 0x010b00040006057102080140c9 (13 bytes) 13:52:27.039 CNTRLR [Node 006] [~] [Notification] notificationMode: "unkno [Endpoint 0] [internal] wn" => "unknown" 13:52:27.040 CNTRLR [Node 006] [+] [Notification] supportedNotificationEvents[8]: 6 [internal] 13:52:27.040 CNTRLR [Node 006] [Notification] Power Management[Over-current status]: [Endpoint 0] metadata updated 13:52:27.041 SERIAL » [ACK] (0x06) 13:52:27.041 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[NotificationCCEventSupportedReport] notification type: Power Management supported events: · Unknown (0x06) 13:52:27.042 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:27.042 DRIVER send thread state: idle 13:52:27.043 CNTRLR « [Node 006] received supported notification events for Power Management: 6 13:52:27.043 CNTRLR [Node 006] [+] [Notification] interviewComplete: true [Endpoint 0] [internal] 13:52:27.043 CNTRLR [Node 006] CentralSceneCC: doing a complete interview... 13:52:27.044 CNTRLR » [Node 006] Querying supported scenes... 13:52:27.046 DRIVER Send queue: (2 messages) · [REQ] SendData (CentralSceneCCSupportedGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:27.048 SERIAL » 0x0109001306025b0125fd63 (11 bytes) 13:52:27.049 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 253 └─[CentralSceneCCSupportedGet] 13:52:27.049 DRIVER send thread state: sending.execute 13:52:27.050 SERIAL « [ACK] (0x06) 13:52:27.051 DRIVER send thread state: sending.execute 13:52:27.057 SERIAL « 0x0104011301e8 (6 bytes) 13:52:27.057 SERIAL » [ACK] (0x06) 13:52:27.057 DRIVER « [RES] [SendData] was sent: true 13:52:27.058 DRIVER send thread state: sending.execute 13:52:27.073 SERIAL « 0x01070013fd00000214 (9 bytes) 13:52:27.073 SERIAL » [ACK] (0x06) 13:52:27.074 DRIVER « [REQ] [SendData] callback id: 253 transmit status: OK 13:52:27.075 DRIVER send thread state: sending.execute 13:52:27.076 DRIVER send thread state: sending.waitForUpdate 13:52:27.085 SERIAL « 0x010c00040006065b0202031f1faf (14 bytes) 13:52:27.087 CNTRLR [Node 006] [Central Scene] scene[001]: metadata updated 13:52:27.088 CNTRLR [Node 006] [Central Scene] scene[002]: metadata updated 13:52:27.089 CNTRLR [Node 006] [+] [Central Scene] sceneCount: 2 [Endpoint 0] [internal] 13:52:27.089 CNTRLR [Node 006] [+] [Central Scene] supportsSlowRefresh: fa [Endpoint 0] [internal] lse 13:52:27.089 CNTRLR [Node 006] [+] [Central Scene] supportedKeyAttributes: [Endpoint 0] [internal] [object Map] 13:52:27.089 SERIAL » [ACK] (0x06) 13:52:27.090 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[CentralSceneCCSupportedReport] scene count: 2 supports slow refresh: false supported attributes (scene #1): · KeyPressed · KeyReleased · KeyHeldDown · KeyPressed2x · KeyPressed3x supported attributes (scene #2): · KeyPressed · KeyReleased · KeyHeldDown · KeyPressed2x · KeyPressed3x 13:52:27.091 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:27.092 DRIVER send thread state: idle 13:52:27.092 CNTRLR « [Node 006] received supported scenes: # of scenes: 2 supports slow refresh: false 13:52:27.092 CNTRLR [Node 006] [+] [Central Scene] interviewComplete: true [Endpoint 0] [internal] 13:52:27.115 CNTRLR [Node 006] Interview stage completed: CommandClasses 13:52:27.116 CNTRLR [Node 006] Interview stage completed: OverwriteConfig 13:52:27.116 CNTRLR » [Node 006] requesting node neighbors... 13:52:27.117 DRIVER Send queue: (2 messages) · [REQ] GetRoutingInfo [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:27.131 SERIAL » 0x01070080060000007e (9 bytes) 13:52:27.131 DRIVER » [Node 006] [REQ] [GetRoutingInfo] remove non-repeaters: false remove bad links: false 13:52:27.131 DRIVER send thread state: sending.execute 13:52:27.133 SERIAL « [ACK] (0x06) 13:52:27.133 DRIVER send thread state: sending.execute 13:52:27.135 SERIAL « 0x0120018041c447d0c0213f3000000000000000000000000000000000000000000 (34 bytes) 0a2 13:52:27.136 SERIAL » [ACK] (0x06) 13:52:27.136 DRIVER « [RES] [GetRoutingInfo] node ids: 1, 7, 11, 15, 16, 17, 18, 19, 23, 29, 31, 32, 39, 40, 41, 46, 49, 50, 51, 52, 53, 54, 61, 62 13:52:27.137 DRIVER send thread state: sending.execute 13:52:27.137 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:27.137 DRIVER send thread state: idle 13:52:27.137 CNTRLR « [Node 006] node neighbors received: 1, 7, 11, 15, 16, 17, 18, 19, 23, 29, 31 , 32, 39, 40, 41, 46, 49, 50, 51, 52, 53, 54, 61, 62 13:52:27.137 CNTRLR [Node 006] Interview stage completed: Neighbors 13:52:27.137 CNTRLR [Node 006] Interview completed 13:52:27.137 CNTRLR [Node 006] The node is ready to be used 13:52:30.388 SERIAL « 0x01140004000f0e3202213400000120000000000000ea (22 bytes) 13:52:30.389 CNTRLR [Node 015] [~] [Meter] value[66049]: 30.2 => 28.8 [Endpoint 0] 13:52:30.389 CNTRLR [Node 015] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:52:30.390 SERIAL » [ACK] (0x06) 13:52:30.391 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 28.8 time delta: 0 seconds 13:52:30.391 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:30.392 DRIVER send thread state: idle 13:52:30.392 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:30.392 DRIVER send thread state: idle 13:52:35.388 SERIAL « 0x01140004000f0e320221340000011f000000000000d5 (22 bytes) 13:52:35.389 CNTRLR [Node 015] [~] [Meter] value[66049]: 28.8 => 28.7 [Endpoint 0] 13:52:35.389 CNTRLR [Node 015] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:52:35.390 SERIAL » [ACK] (0x06) 13:52:35.390 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 28.7 time delta: 0 seconds 13:52:35.391 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:35.391 DRIVER send thread state: idle 13:52:35.392 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:35.392 DRIVER send thread state: idle 13:52:36.131 SERIAL « 0x0114000400100e3202213400000114000000000000c1 (22 bytes) 13:52:36.131 CNTRLR [Node 016] [~] [Meter] value[66049]: 27.7 => 27.6 [Endpoint 0] 13:52:36.131 CNTRLR [Node 016] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:52:36.131 SERIAL » [ACK] (0x06) 13:52:36.132 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 27.6 time delta: 0 seconds 13:52:36.132 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:36.132 DRIVER send thread state: idle 13:52:36.132 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:36.132 DRIVER send thread state: idle 13:52:39.502 SERIAL « 0x010c00040036063105042203f026 (14 bytes) 13:52:39.503 CNTRLR [Node 054] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 13:52:39.504 CNTRLR [Node 054] [~] [Multilevel Sensor] Power: 126.7 => 100.8 [Endpoint 0] 13:52:39.504 SERIAL » [ACK] (0x06) 13:52:39.505 DRIVER « [Node 054] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 100.8 13:52:39.505 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:39.506 DRIVER send thread state: idle 13:52:39.506 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:39.506 DRIVER send thread state: idle 13:52:42.386 SERIAL « 0x01140004000f0e320221340000012d000000000000e7 (22 bytes) 13:52:42.387 CNTRLR [Node 015] [~] [Meter] value[66049]: 28.7 => 30.1 [Endpoint 0] 13:52:42.387 CNTRLR [Node 015] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:52:42.387 SERIAL » [ACK] (0x06) 13:52:42.387 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 30.1 time delta: 0 seconds 13:52:42.388 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:42.388 DRIVER send thread state: idle 13:52:42.388 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:42.388 DRIVER send thread state: idle 13:52:46.502 SERIAL « 0x010c00040036063105042204e332 (14 bytes) 13:52:46.502 CNTRLR [Node 054] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 13:52:46.503 CNTRLR [Node 054] [~] [Multilevel Sensor] Power: 100.8 => 125.1 [Endpoint 0] 13:52:46.503 SERIAL » [ACK] (0x06) 13:52:46.503 DRIVER « [Node 054] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 125.1 13:52:46.503 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:46.503 DRIVER send thread state: idle 13:52:46.503 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:46.503 DRIVER send thread state: idle 13:52:48.388 SERIAL « 0x01140004000f0e3202213400000127000000000000ed (22 bytes) 13:52:48.389 CNTRLR [Node 015] [~] [Meter] value[66049]: 30.1 => 29.5 [Endpoint 0] 13:52:48.389 CNTRLR [Node 015] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:52:48.390 SERIAL » [ACK] (0x06) 13:52:48.390 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 29.5 time delta: 0 seconds 13:52:48.391 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:48.391 DRIVER send thread state: idle 13:52:48.392 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:48.392 DRIVER send thread state: idle 13:52:49.502 SERIAL « 0x010c00040036063105042203d600 (14 bytes) 13:52:49.502 CNTRLR [Node 054] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 13:52:49.503 CNTRLR [Node 054] [~] [Multilevel Sensor] Power: 125.1 => 98.2 [Endpoint 0] 13:52:49.503 SERIAL » [ACK] (0x06) 13:52:49.504 DRIVER « [Node 054] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 98.2 13:52:49.504 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:49.504 DRIVER send thread state: idle 13:52:49.505 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:49.505 DRIVER send thread state: idle 13:52:50.388 SERIAL « 0x01140004000f0e320221340000011b000000000000d1 (22 bytes) 13:52:50.389 CNTRLR [Node 015] [~] [Meter] value[66049]: 29.5 => 28.3 [Endpoint 0] 13:52:50.390 CNTRLR [Node 015] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:52:50.391 SERIAL » [ACK] (0x06) 13:52:50.392 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 28.3 time delta: 0 seconds 13:52:50.392 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:50.392 DRIVER send thread state: idle 13:52:50.393 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:50.393 DRIVER send thread state: idle 13:52:54.502 SERIAL « 0x010c00040036063105042204b362 (14 bytes) 13:52:54.503 CNTRLR [Node 054] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 13:52:54.504 CNTRLR [Node 054] [~] [Multilevel Sensor] Power: 98.2 => 120.3 [Endpoint 0] 13:52:54.504 SERIAL » [ACK] (0x06) 13:52:54.505 DRIVER « [Node 054] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 120.3 13:52:54.505 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:54.505 DRIVER send thread state: idle 13:52:54.506 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:54.506 DRIVER send thread state: idle 13:52:56.502 SERIAL « 0x010c00040036063105042203a573 (14 bytes) 13:52:56.503 CNTRLR [Node 054] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 13:52:56.503 CNTRLR [Node 054] [~] [Multilevel Sensor] Power: 120.3 => 93.3 [Endpoint 0] 13:52:56.504 SERIAL » [ACK] (0x06) 13:52:56.504 DRIVER « [Node 054] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 93.3 13:52:56.505 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:56.505 DRIVER send thread state: idle 13:52:56.505 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:52:56.505 DRIVER send thread state: idle 13:53:03.388 SERIAL « 0x01140004000f0e3202213400000130000000000000fa (22 bytes) 13:53:03.389 CNTRLR [Node 015] [~] [Meter] value[66049]: 28.3 => 30.4 [Endpoint 0] 13:53:03.389 CNTRLR [Node 015] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:53:03.389 SERIAL » [ACK] (0x06) 13:53:03.390 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 30.4 time delta: 0 seconds 13:53:03.392 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:03.392 DRIVER send thread state: idle 13:53:03.393 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:03.393 DRIVER send thread state: idle 13:53:05.388 SERIAL « 0x01140004000f0e3202213400000123000000000000e9 (22 bytes) 13:53:05.389 CNTRLR [Node 015] [~] [Meter] value[66049]: 30.4 => 29.1 [Endpoint 0] 13:53:05.389 CNTRLR [Node 015] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:53:05.389 SERIAL » [ACK] (0x06) 13:53:05.390 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 29.1 time delta: 0 seconds 13:53:05.391 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:05.391 DRIVER send thread state: idle 13:53:05.391 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:05.392 DRIVER send thread state: idle 13:53:10.388 SERIAL « 0x01140004000f0e3202213400000122000000000000e8 (22 bytes) 13:53:10.389 CNTRLR [Node 015] [~] [Meter] value[66049]: 29.1 => 29 [Endpoint 0] 13:53:10.389 CNTRLR [Node 015] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:53:10.390 SERIAL » [ACK] (0x06) 13:53:10.390 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 29 time delta: 0 seconds 13:53:10.391 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:10.391 DRIVER send thread state: idle 13:53:10.392 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:10.392 DRIVER send thread state: idle 13:53:20.131 SERIAL « 0x0114000400100e3202213400000115000000000000c0 (22 bytes) 13:53:20.132 CNTRLR [Node 016] [~] [Meter] value[66049]: 27.6 => 27.7 [Endpoint 0] 13:53:20.132 CNTRLR [Node 016] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:53:20.133 SERIAL » [ACK] (0x06) 13:53:20.135 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 27.7 time delta: 0 seconds 13:53:20.135 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:20.136 DRIVER send thread state: idle 13:53:20.136 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:20.136 DRIVER send thread state: idle 13:53:20.387 SERIAL « 0x01140004000f0e3202213400000120000000000000ea (22 bytes) 13:53:20.388 CNTRLR [Node 015] [~] [Meter] value[66049]: 29 => 28.8 [Endpoint 0] 13:53:20.389 CNTRLR [Node 015] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:53:20.389 SERIAL » [ACK] (0x06) 13:53:20.390 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 28.8 time delta: 0 seconds 13:53:20.390 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:20.391 DRIVER send thread state: idle 13:53:20.391 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:20.391 DRIVER send thread state: idle 13:53:24.018 DRIVER Send queue: (2 messages) · [REQ] SendData (MeterCCReset) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:24.026 SERIAL » 0x010900130602320525fe0d (11 bytes) 13:53:24.026 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 254 └─[MeterCCReset] 13:53:24.026 DRIVER send thread state: sending.execute 13:53:24.027 SERIAL « [ACK] (0x06) 13:53:24.028 DRIVER send thread state: sending.execute 13:53:24.034 SERIAL « 0x0104011301e8 (6 bytes) 13:53:24.034 SERIAL » [ACK] (0x06) 13:53:24.034 DRIVER « [RES] [SendData] was sent: true 13:53:24.034 DRIVER send thread state: sending.execute 13:53:24.051 SERIAL « 0x01070013fe00000217 (9 bytes) 13:53:24.051 SERIAL » [ACK] (0x06) 13:53:24.051 DRIVER « [REQ] [SendData] callback id: 254 transmit status: OK 13:53:24.052 DRIVER send thread state: sending.execute 13:53:24.052 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:24.052 DRIVER send thread state: idle 13:53:24.052 DRIVER Send queue: (2 messages) · [REQ] SendData (MeterCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:24.054 SERIAL » 0x010a0013060332010025ff0a (12 bytes) 13:53:24.054 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 255 └─[MeterCCGet] duration: kWh 13:53:24.054 DRIVER send thread state: sending.execute 13:53:24.056 SERIAL « [ACK] (0x06) 13:53:24.056 DRIVER send thread state: sending.execute 13:53:24.062 SERIAL « 0x0104011301e8 (6 bytes) 13:53:24.062 SERIAL » [ACK] (0x06) 13:53:24.062 DRIVER « [RES] [SendData] was sent: true 13:53:24.063 DRIVER send thread state: sending.execute 13:53:24.079 SERIAL « 0x01070013ff00000216 (9 bytes) 13:53:24.079 SERIAL » [ACK] (0x06) 13:53:24.079 DRIVER « [REQ] [SendData] callback id: 255 transmit status: OK 13:53:24.080 DRIVER send thread state: sending.execute 13:53:24.080 DRIVER send thread state: sending.waitForUpdate 13:53:24.091 SERIAL « 0x0110000400060a32022144000000000000b2 (18 bytes) 13:53:24.092 CNTRLR [Node 006] [~] [Meter] value[65537]: 0 => 0 [Endpoint 0] 13:53:24.092 CNTRLR [Node 006] [~] [Meter] deltaTime[65537]: 0 => 0 [Endpoint 0] 13:53:24.092 SERIAL » [ACK] (0x06) 13:53:24.093 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 0 time delta: 0 seconds 13:53:24.094 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:24.094 DRIVER send thread state: idle 13:53:24.095 DRIVER Send queue: (2 messages) · [REQ] SendData (MeterCCGet) [Node 6, awake] · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:24.096 SERIAL » 0x010a001306033201102501e4 (12 bytes) 13:53:24.096 DRIVER » [Node 006] [REQ] [SendData] │ transmit options: 0x25 │ callback id: 1 └─[MeterCCGet] duration: W 13:53:24.096 DRIVER send thread state: sending.execute 13:53:24.097 SERIAL « [ACK] (0x06) 13:53:24.098 DRIVER send thread state: sending.execute 13:53:24.104 SERIAL « 0x0104011301e8 (6 bytes) 13:53:24.104 SERIAL » [ACK] (0x06) 13:53:24.104 DRIVER « [RES] [SendData] was sent: true 13:53:24.105 DRIVER send thread state: sending.execute 13:53:24.120 SERIAL « 0x0107001301000002e8 (9 bytes) 13:53:24.120 SERIAL » [ACK] (0x06) 13:53:24.120 DRIVER « [REQ] [SendData] callback id: 1 transmit status: OK 13:53:24.122 DRIVER send thread state: sending.execute 13:53:24.122 DRIVER send thread state: sending.waitForUpdate 13:53:24.132 SERIAL « 0x010e00040006083202213200000000d8 (16 bytes) 13:53:24.132 CNTRLR [Node 006] [~] [Meter] value[66049]: 0 => 0 [Endpoint 0] 13:53:24.133 CNTRLR [Node 006] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:53:24.133 SERIAL » [ACK] (0x06) 13:53:24.133 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 0 time delta: 0 seconds 13:53:24.134 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:24.134 DRIVER send thread state: idle 13:53:24.752 SERIAL « 0x0114000400060e600d010132022144000000000000df (22 bytes) 13:53:24.753 CNTRLR [Node 006] [Meter] value[65537]: metadata updated [Endpoint 1] 13:53:24.754 CNTRLR [Node 006] [+] [Meter] value[65537]: 0 [Endpoint 1] 13:53:24.754 CNTRLR [Node 006] [+] [Meter] deltaTime[65537]: 0 [Endpoint 1] 13:53:24.755 SERIAL » [ACK] (0x06) 13:53:24.756 DRIVER « [Node 006] [REQ] [ApplicationCommand] └─[MultiChannelCCCommandEncapsulation] │ source: 1 │ destination: 1 └─[MeterCCReport] type: Electric scale: kWh rate type: Consumed value: 0 time delta: 0 seconds 13:53:24.756 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:24.756 DRIVER send thread state: idle 13:53:24.757 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:24.757 DRIVER send thread state: idle 13:53:29.502 SERIAL « 0x010c000400360631050422043eef (14 bytes) 13:53:29.503 CNTRLR [Node 054] [Multilevel Sensor] Power: metadata updated [Endpoint 0] 13:53:29.504 CNTRLR [Node 054] [~] [Multilevel Sensor] Power: 93.3 => 108.6 [Endpoint 0] 13:53:29.504 SERIAL » [ACK] (0x06) 13:53:29.507 DRIVER « [Node 054] [REQ] [ApplicationCommand] └─[MultilevelSensorCCReport] type: Power scale: Watt value: 108.6 13:53:29.507 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:29.508 DRIVER send thread state: idle 13:53:29.508 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:29.508 DRIVER send thread state: idle 13:53:30.389 SERIAL « 0x01140004000f0e320221340000011e000000000000d4 (22 bytes) 13:53:30.390 CNTRLR [Node 015] [~] [Meter] value[66049]: 28.8 => 28.6 [Endpoint 0] 13:53:30.390 CNTRLR [Node 015] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:53:30.390 SERIAL » [ACK] (0x06) 13:53:30.391 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 28.6 time delta: 0 seconds 13:53:30.392 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:30.392 DRIVER send thread state: idle 13:53:30.393 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:30.393 DRIVER send thread state: idle 13:53:33.130 SERIAL « 0x0114000400100e3202213400000111000000000000c4 (22 bytes) 13:53:33.131 CNTRLR [Node 016] [~] [Meter] value[66049]: 27.7 => 27.3 [Endpoint 0] 13:53:33.132 CNTRLR [Node 016] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:53:33.132 SERIAL » [ACK] (0x06) 13:53:33.133 DRIVER « [Node 016] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 27.3 time delta: 0 seconds 13:53:33.133 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:33.134 DRIVER send thread state: idle 13:53:33.134 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:33.135 DRIVER send thread state: idle 13:53:34.389 SERIAL « 0x01140004000f0e3202213400000134000000000000fe (22 bytes) 13:53:34.389 CNTRLR [Node 015] [~] [Meter] value[66049]: 28.6 => 30.8 [Endpoint 0] 13:53:34.390 CNTRLR [Node 015] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:53:34.390 SERIAL » [ACK] (0x06) 13:53:34.391 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 30.8 time delta: 0 seconds 13:53:34.393 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:34.394 DRIVER send thread state: idle 13:53:34.394 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:34.394 DRIVER send thread state: idle 13:53:36.389 SERIAL « 0x01140004000f0e3202213400000124000000000000ee (22 bytes) 13:53:36.390 CNTRLR [Node 015] [~] [Meter] value[66049]: 30.8 => 29.2 [Endpoint 0] 13:53:36.390 CNTRLR [Node 015] [~] [Meter] deltaTime[66049]: 0 => 0 [Endpoint 0] 13:53:36.391 SERIAL » [ACK] (0x06) 13:53:36.392 DRIVER « [Node 015] [REQ] [ApplicationCommand] └─[MeterCCReport] type: Electric scale: W rate type: Consumed value: 29.2 time delta: 0 seconds 13:53:36.392 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:36.393 DRIVER send thread state: idle 13:53:36.393 DRIVER Send queue: (1 message) · [REQ] SendData (ManufacturerSpecificCCGet) [Node 30, asleep] 13:53:36.393 DRIVER send thread state: idle