2025-02-09 14:25:13.745 - info: kecontact.0 (17365) Got terminate signal TERMINATE_YOURSELF 2025-02-09 14:25:13.748 - info: kecontact.0 (17365) terminating 2025-02-09 14:25:13.749 - info: kecontact.0 (17365) Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason 2025-02-09 14:25:13.820 - info: host.ioBroker stopInstance system.adapter.kecontact.0 send kill signal 2025-02-09 14:25:14.250 - info: kecontact.0 (17365) terminating 2025-02-09 14:25:14.340 - info: host.ioBroker instance system.adapter.kecontact.0 terminated with code 11 (ADAPTER_REQUESTED_TERMINATION) 2025-02-09 14:25:17.854 - info: host.ioBroker instance system.adapter.kecontact.0 in version "2.3.0" (non-npm: iobroker-community-adapters/ioBroker.kecontact#new-core-base) started with pid 17578 2025-02-09 14:25:18.817 - debug: kecontact.0 (17578) Redis Objects: Use Redis connection: 127.0.0.1:9001 2025-02-09 14:25:18.845 - debug: kecontact.0 (17578) Objects client ready ... initialize now 2025-02-09 14:25:18.846 - debug: kecontact.0 (17578) Objects create System PubSub Client 2025-02-09 14:25:18.847 - debug: kecontact.0 (17578) Objects create User PubSub Client 2025-02-09 14:25:18.888 - debug: kecontact.0 (17578) Objects client initialize lua scripts 2025-02-09 14:25:18.892 - debug: kecontact.0 (17578) Objects connected to redis: 127.0.0.1:9001 2025-02-09 14:25:18.916 - debug: kecontact.0 (17578) Redis States: Use Redis connection: 127.0.0.1:9000 2025-02-09 14:25:18.975 - debug: kecontact.0 (17578) States create System PubSub Client 2025-02-09 14:25:18.977 - debug: kecontact.0 (17578) States create User PubSub Client 2025-02-09 14:25:19.045 - debug: kecontact.0 (17578) States connected to redis: 127.0.0.1:9000 2025-02-09 14:25:19.076 - debug: kecontact.0 (17578) Plugin sentry Do not initialize Plugin (enabled=false) 2025-02-09 14:25:19.685 - info: kecontact.0 (17578) starting. Version 2.3.0 (non-npm: iobroker-community-adapters/ioBroker.kecontact#new-core-base) in /opt/iobroker/node_modules/iobroker.kecontact, node: v20.18.2, js-controller: 7.0.6 2025-02-09 14:25:19.701 - info: kecontact.0 (17578) starting charging station in active mode 2025-02-09 14:25:19.703 - info: kecontact.0 (17578) Using min time between phase switching of: 305 2025-02-09 14:25:19.716 - info: kecontact.0 (17578) config host: 10.1.4.9 2025-02-09 14:25:19.716 - info: kecontact.0 (17578) config passiveMode: false 2025-02-09 14:25:19.716 - info: kecontact.0 (17578) config pollInterval: 30 2025-02-09 14:25:19.716 - info: kecontact.0 (17578) config loadChargingSessions: true 2025-02-09 14:25:19.717 - info: kecontact.0 (17578) config useX1forAutomatic: false 2025-02-09 14:25:19.717 - info: kecontact.0 (17578) config stateRegard: modbus.0.holdingRegisters.200.40087_W 2025-02-09 14:25:19.717 - info: kecontact.0 (17578) config stateSurplus: 2025-02-09 14:25:19.717 - info: kecontact.0 (17578) config stateBatteryCharging: modbus.0.holdingRegisters.1.40314_3_DCW 2025-02-09 14:25:19.717 - info: kecontact.0 (17578) config stateBatteryDischarging: modbus.0.holdingRegisters.1.40334_4_DCW 2025-02-09 14:25:19.717 - info: kecontact.0 (17578) config stateBatterySoC: modbus.0.holdingRegisters.1.40354_ChaSt 2025-02-09 14:25:19.717 - info: kecontact.0 (17578) config batteryPower: 7000 2025-02-09 14:25:19.717 - info: kecontact.0 (17578) config batteryMinSoC: 25 2025-02-09 14:25:19.717 - info: kecontact.0 (17578) config batteryStorageStrategy: 4 2025-02-09 14:25:19.718 - info: kecontact.0 (17578) config statesIncludeWallbox: true 2025-02-09 14:25:19.718 - info: kecontact.0 (17578) config.state1p3pSwitch: 2025-02-09 14:25:19.718 - info: kecontact.0 (17578) config.1p3pViax2: true 2025-02-09 14:25:19.718 - info: kecontact.0 (17578) config.1p3pSwitchIsNO: true, 1p = 0, 3p = 1, off = 0 2025-02-09 14:25:19.718 - info: kecontact.0 (17578) config minAmperage: 6000 2025-02-09 14:25:19.718 - info: kecontact.0 (17578) config addPower: 250 2025-02-09 14:25:19.718 - info: kecontact.0 (17578) config delta: 1000 2025-02-09 14:25:19.718 - info: kecontact.0 (17578) config underusage: 500 2025-02-09 14:25:19.718 - info: kecontact.0 (17578) config minTime: 300 2025-02-09 14:25:19.718 - info: kecontact.0 (17578) config regardTime: 180 2025-02-09 14:25:19.719 - info: kecontact.0 (17578) config stateEnWG: 2025-02-09 14:25:19.719 - info: kecontact.0 (17578) config dynamicEnWG: false 2025-02-09 14:25:19.719 - info: kecontact.0 (17578) config maxPower: 23000 2025-02-09 14:25:19.719 - info: kecontact.0 (17578) config stateEnergyMeter1: modbus.0.holdingRegisters.200.40087_W 2025-02-09 14:25:19.719 - info: kecontact.0 (17578) config stateEnergyMeter2: 2025-02-09 14:25:19.719 - info: kecontact.0 (17578) config stateEnergyMeter3: 2025-02-09 14:25:19.722 - info: kecontact.0 (17578) config wallboxNotIncluded: false 2025-02-09 14:25:19.738 - debug: kecontact.0 (17578) UDP server listening on 0.0.0.0:7090 2025-02-09 14:25:19.738 - debug: kecontact.0 (17578) UDP broadcast server listening on 0.0.0.0:7092 2025-02-09 14:25:20.993 - debug: kecontact.0 (17578) subscribe state modbus.0.holdingRegisters.200.40087_W - current value: 1.88 2025-02-09 14:25:20.996 - debug: kecontact.0 (17578) subscribe state modbus.0.holdingRegisters.1.40314_3_DCW - current value: 4385.3 2025-02-09 14:25:20.997 - debug: kecontact.0 (17578) subscribe state modbus.0.holdingRegisters.1.40334_4_DCW - current value: 0 2025-02-09 14:25:20.997 - debug: kecontact.0 (17578) subscribe state modbus.0.holdingRegisters.1.40354_ChaSt - current value: 4 2025-02-09 14:25:20.997 - debug: kecontact.0 (17578) subscribe state modbus.0.holdingRegisters.200.40087_W - current value: 1.88 2025-02-09 14:25:21.043 - debug: kecontact.0 (17578) Sent "report 1" to 10.1.4.9:7090 2025-02-09 14:25:21.046 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "1", "Product": "KC-P30-ES2400B2-L0A-GE", "Serial": "26663654", "Firmware":"P30 v 3.10.61 (241209-090525)", "COM-module": 1, "Backend": 0, "timeQ": 3, "setBoot": 0, "DIP-Sw1": "0x25", "DIP-Sw2": "0x08", "Sec": 707953 } " 2025-02-09 14:25:21.363 - debug: kecontact.0 (17578) Sent "report 101" to 10.1.4.9:7090 2025-02-09 14:25:21.365 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "101", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 0, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 707953 } " 2025-02-09 14:25:21.366 - debug: kecontact.0 (17578) History ID received: 01 2025-02-09 14:25:21.664 - debug: kecontact.0 (17578) Sent "report 102" to 10.1.4.9:7090 2025-02-09 14:25:21.666 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "102", "Session ID": 357, "Curr HW": 32000, "E start": 56252580, "E pres": 17393, "started[s]": 1739025207, "ended[s]": 1739026515, "started": "2025-02-08 14:33:27.000", "ended": "2025-02-08 14:55:15.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "a0cefa65000000000000", "Serial": "26663654", "Sec": 707953 } " 2025-02-09 14:25:21.671 - debug: kecontact.0 (17578) History ID received: 02 2025-02-09 14:25:21.972 - debug: kecontact.0 (17578) Sent "report 103" to 10.1.4.9:7090 2025-02-09 14:25:21.975 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "103", "Session ID": 356, "Curr HW": 32000, "E start": 56172935, "E pres": 79645, "started[s]": 1739015785, "ended[s]": 1739022334, "started": "2025-02-08 11:56:25.000", "ended": "2025-02-08 13:45:34.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "28096b65000000000000", "Serial": "26663654", "Sec": 707953 } " 2025-02-09 14:25:21.975 - debug: kecontact.0 (17578) History ID received: 03 2025-02-09 14:25:22.271 - debug: kecontact.0 (17578) Sent "report 104" to 10.1.4.9:7090 2025-02-09 14:25:22.274 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "104", "Session ID": 355, "Curr HW": 32000, "E start": 55766682, "E pres": 406253, "started[s]": 1738956995, "ended[s]": 1738986290, "started": "2025-02-07 19:36:35.000", "ended": "2025-02-08 03:44:50.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "32fae961000000000000", "Serial": "26663654", "Sec": 707954 } " 2025-02-09 14:25:22.275 - debug: kecontact.0 (17578) History ID received: 04 2025-02-09 14:25:22.571 - debug: kecontact.0 (17578) Sent "report 105" to 10.1.4.9:7090 2025-02-09 14:25:22.574 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "105", "Session ID": 354, "Curr HW": 32000, "E start": 55515840, "E pres": 250842, "started[s]": 1738876325, "ended[s]": 1738898390, "started": "2025-02-06 21:12:05.000", "ended": "2025-02-07 03:19:50.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "fd0a1b5d000000000000", "Serial": "26663654", "Sec": 707954 } " 2025-02-09 14:25:22.575 - debug: kecontact.0 (17578) History ID received: 05 2025-02-09 14:25:22.871 - debug: kecontact.0 (17578) Sent "report 106" to 10.1.4.9:7090 2025-02-09 14:25:22.874 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "106", "Session ID": 353, "Curr HW": 32000, "E start": 55422917, "E pres": 92923, "started[s]": 1738784299, "ended[s]": 1738810370, "started": "2025-02-05 19:38:19.000", "ended": "2025-02-06 02:52:50.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "bdd59e57000000000000", "Serial": "26663654", "Sec": 707954 } " 2025-02-09 14:25:22.875 - debug: kecontact.0 (17578) History ID received: 06 2025-02-09 14:25:23.171 - debug: kecontact.0 (17578) Sent "report 107" to 10.1.4.9:7090 2025-02-09 14:25:23.174 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "107", "Session ID": 352, "Curr HW": 32000, "E start": 55420159, "E pres": 2758, "started[s]": 1738782242, "ended[s]": 1738782486, "started": "2025-02-05 19:04:02.000", "ended": "2025-02-05 19:08:06.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "d2747f57000000000000", "Serial": "26663654", "Sec": 707955 } " 2025-02-09 14:25:23.175 - debug: kecontact.0 (17578) History ID received: 07 2025-02-09 14:25:23.471 - debug: kecontact.0 (17578) Sent "report 108" to 10.1.4.9:7090 2025-02-09 14:25:23.475 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "108", "Session ID": 351, "Curr HW": 32000, "E start": 55329176, "E pres": 90983, "started[s]": 1738750511, "ended[s]": 1738756670, "started": "2025-02-05 10:15:11.000", "ended": "2025-02-05 11:57:50.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "17459b55000000000000", "Serial": "26663654", "Sec": 707955 } " 2025-02-09 14:25:23.476 - debug: kecontact.0 (17578) History ID received: 08 2025-02-09 14:25:23.772 - debug: kecontact.0 (17578) Sent "report 109" to 10.1.4.9:7090 2025-02-09 14:25:23.774 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "109", "Session ID": 350, "Curr HW": 32000, "E start": 55328669, "E pres": 507, "started[s]": 1738741506, "ended[s]": 1738747178, "started": "2025-02-05 07:45:06.000", "ended": "2025-02-05 09:19:38.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "d2de1155000000000000", "Serial": "26663654", "Sec": 707955 } " 2025-02-09 14:25:23.774 - debug: kecontact.0 (17578) History ID received: 09 2025-02-09 14:25:24.072 - debug: kecontact.0 (17578) Sent "report 110" to 10.1.4.9:7090 2025-02-09 14:25:24.074 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "110", "Session ID": 349, "Curr HW": 32000, "E start": 55324879, "E pres": 3790, "started[s]": 1738738630, "ended[s]": 1738741435, "started": "2025-02-05 06:57:10.000", "ended": "2025-02-05 07:43:55.000", "reason": 1, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "adfde554000000000000", "Serial": "26663654", "Sec": 707956 } " 2025-02-09 14:25:24.074 - debug: kecontact.0 (17578) History ID received: 10 2025-02-09 14:25:24.372 - debug: kecontact.0 (17578) Sent "report 111" to 10.1.4.9:7090 2025-02-09 14:25:24.374 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "111", "Session ID": 348, "Curr HW": 32000, "E start": 55148679, "E pres": 176200, "started[s]": 1738689511, "ended[s]": 1738737038, "started": "2025-02-04 17:18:31.000", "ended": "2025-02-05 06:30:38.000", "reason": 1, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "3e7cf851000000000000", "Serial": "26663654", "Sec": 707956 } " 2025-02-09 14:25:24.375 - debug: kecontact.0 (17578) History ID received: 11 2025-02-09 14:25:24.673 - debug: kecontact.0 (17578) Sent "report 112" to 10.1.4.9:7090 2025-02-09 14:25:24.675 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "112", "Session ID": 347, "Curr HW": 32000, "E start": 55107767, "E pres": 40912, "started[s]": 1738684528, "ended[s]": 1738687163, "started": "2025-02-04 15:55:28.000", "ended": "2025-02-04 16:39:23.000", "reason": 1, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "c474ac51000000000000", "Serial": "26663654", "Sec": 707956 } " 2025-02-09 14:25:24.675 - debug: kecontact.0 (17578) History ID received: 12 2025-02-09 14:25:24.973 - debug: kecontact.0 (17578) Sent "report 113" to 10.1.4.9:7090 2025-02-09 14:25:24.975 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "113", "Session ID": 346, "Curr HW": 32000, "E start": 54948114, "E pres": 159653, "started[s]": 1738612669, "ended[s]": 1738636189, "started": "2025-02-03 19:57:49.000", "ended": "2025-02-04 02:29:49.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "a8f7634d000000000000", "Serial": "26663654", "Sec": 707956 } " 2025-02-09 14:25:24.976 - debug: kecontact.0 (17578) History ID received: 13 2025-02-09 14:25:25.274 - debug: kecontact.0 (17578) Sent "report 114" to 10.1.4.9:7090 2025-02-09 14:25:25.275 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "114", "Session ID": 345, "Curr HW": 32000, "E start": 54936312, "E pres": 11802, "started[s]": 1738610258, "ended[s]": 1738611119, "started": "2025-02-03 19:17:38.000", "ended": "2025-02-03 19:31:59.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "232e3f4d000000000000", "Serial": "26663654", "Sec": 707957 } " 2025-02-09 14:25:25.275 - debug: kecontact.0 (17578) History ID received: 14 2025-02-09 14:25:25.573 - debug: kecontact.0 (17578) Sent "report 115" to 10.1.4.9:7090 2025-02-09 14:25:25.576 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "115", "Session ID": 344, "Curr HW": 32000, "E start": 54932983, "E pres": 3329, "started[s]": 1738607349, "ended[s]": 1738608718, "started": "2025-02-03 18:29:09.000", "ended": "2025-02-03 18:51:58.000", "reason": 1, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "f8cb124d000000000000", "Serial": "26663654", "Sec": 707957 } " 2025-02-09 14:25:25.576 - debug: kecontact.0 (17578) History ID received: 15 2025-02-09 14:25:25.873 - debug: kecontact.0 (17578) Sent "report 116" to 10.1.4.9:7090 2025-02-09 14:25:25.876 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "116", "Session ID": 343, "Curr HW": 32000, "E start": 54932983, "E pres": 0, "started[s]": 1738606990, "ended[s]": 1738607300, "started": "2025-02-03 18:23:10.000", "ended": "2025-02-03 18:28:20.000", "reason": 1, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "fb6d0c4d000000000000", "Serial": "26663654", "Sec": 707957 } " 2025-02-09 14:25:25.876 - debug: kecontact.0 (17578) History ID received: 16 2025-02-09 14:25:26.175 - debug: kecontact.0 (17578) Sent "report 117" to 10.1.4.9:7090 2025-02-09 14:25:26.177 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "117", "Session ID": 342, "Curr HW": 32000, "E start": 54564592, "E pres": 368391, "started[s]": 1738511011, "ended[s]": 1738523411, "started": "2025-02-02 15:43:31.000", "ended": "2025-02-02 19:10:11.000", "reason": 4, "timeQ": 3, "RFID tag": "0000000000000000", "RFID class": "f6c95447000000000000", "Serial": "26663654", "Sec": 707958 } " 2025-02-09 14:25:26.177 - debug: kecontact.0 (17578) History ID received: 17 2025-02-09 14:25:26.475 - debug: kecontact.0 (17578) Sent "report 118" to 10.1.4.9:7090 2025-02-09 14:25:26.477 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "118", "Session ID": 341, "Curr HW": 32000, "E start": 54564592, "E pres": 0, "started[s]": 1738510766, "ended[s]": 1738510788, "started": "2025-02-02 15:39:26.000", "ended": "2025-02-02 15:39:48.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9e095147000000000000", "Serial": "26663654", "Sec": 707958 } " 2025-02-09 14:25:26.477 - debug: kecontact.0 (17578) History ID received: 18 2025-02-09 14:25:26.775 - debug: kecontact.0 (17578) Sent "report 119" to 10.1.4.9:7090 2025-02-09 14:25:26.778 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "119", "Session ID": 340, "Curr HW": 32000, "E start": 54008922, "E pres": 555670, "started[s]": 1738341312, "ended[s]": 1738359765, "started": "2025-01-31 16:35:12.000", "ended": "2025-01-31 21:42:45.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "3365373d000000000000", "Serial": "26663654", "Sec": 707958 } " 2025-02-09 14:25:26.779 - debug: kecontact.0 (17578) History ID received: 19 2025-02-09 14:25:27.076 - debug: kecontact.0 (17578) Sent "report 120" to 10.1.4.9:7090 2025-02-09 14:25:27.079 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "120", "Session ID": 339, "Curr HW": 32000, "E start": 53969185, "E pres": 39737, "started[s]": 1738324919, "ended[s]": 1738326262, "started": "2025-01-31 12:01:59.000", "ended": "2025-01-31 12:24:22.000", "reason": 1, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "20423d3c000000000000", "Serial": "26663654", "Sec": 707959 } " 2025-02-09 14:25:27.080 - debug: kecontact.0 (17578) History ID received: 20 2025-02-09 14:25:27.375 - debug: kecontact.0 (17578) Sent "report 121" to 10.1.4.9:7090 2025-02-09 14:25:27.378 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "121", "Session ID": 338, "Curr HW": 32000, "E start": 53533859, "E pres": 435326, "started[s]": 1738183970, "ended[s]": 1738218636, "started": "2025-01-29 20:52:50.000", "ended": "2025-01-30 06:30:36.000", "reason": 1, "timeQ": 3, "RFID tag": "0000000000000000", "RFID class": "f68ad633000000000000", "Serial": "26663654", "Sec": 707959 } " 2025-02-09 14:25:27.378 - debug: kecontact.0 (17578) History ID received: 21 2025-02-09 14:25:27.676 - debug: kecontact.0 (17578) Sent "report 122" to 10.1.4.9:7090 2025-02-09 14:25:27.678 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "122", "Session ID": 337, "Curr HW": 32000, "E start": 53525058, "E pres": 8801, "started[s]": 1738183017, "ended[s]": 1738183926, "started": "2025-01-29 20:36:57.000", "ended": "2025-01-29 20:52:06.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "7c38c733000000000000", "Serial": "26663654", "Sec": 707959 } " 2025-02-09 14:25:27.678 - debug: kecontact.0 (17578) History ID received: 22 2025-02-09 14:25:27.976 - debug: kecontact.0 (17578) Sent "report 123" to 10.1.4.9:7090 2025-02-09 14:25:27.979 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "123", "Session ID": 336, "Curr HW": 32000, "E start": 53046507, "E pres": 478551, "started[s]": 1737898518, "ended[s]": 1737914459, "started": "2025-01-26 13:35:18.000", "ended": "2025-01-26 18:00:59.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "53e4d222000000000000", "Serial": "26663654", "Sec": 707959 } " 2025-02-09 14:25:27.980 - debug: kecontact.0 (17578) History ID received: 23 2025-02-09 14:25:28.276 - debug: kecontact.0 (17578) Sent "report 124" to 10.1.4.9:7090 2025-02-09 14:25:28.278 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "124", "Session ID": 335, "Curr HW": 32000, "E start": 52833551, "E pres": 212956, "started[s]": 1737818193, "ended[s]": 1737872310, "started": "2025-01-25 15:16:33.000", "ended": "2025-01-26 06:18:30.000", "reason": 1, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "b33b091e000000000000", "Serial": "26663654", "Sec": 707960 } " 2025-02-09 14:25:28.279 - debug: kecontact.0 (17578) History ID received: 24 2025-02-09 14:25:28.576 - debug: kecontact.0 (17578) Sent "report 125" to 10.1.4.9:7090 2025-02-09 14:25:28.578 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "125", "Session ID": 334, "Curr HW": 32000, "E start": 52368141, "E pres": 465410, "started[s]": 1737746079, "ended[s]": 1737761586, "started": "2025-01-24 19:14:39.000", "ended": "2025-01-24 23:33:06.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "d1dabc19000000000000", "Serial": "26663654", "Sec": 707960 } " 2025-02-09 14:25:28.578 - debug: kecontact.0 (17578) History ID received: 25 2025-02-09 14:25:28.876 - debug: kecontact.0 (17578) Sent "report 126" to 10.1.4.9:7090 2025-02-09 14:25:28.879 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "126", "Session ID": 333, "Curr HW": 32000, "E start": 52066425, "E pres": 301716, "started[s]": 1737481049, "ended[s]": 1737491106, "started": "2025-01-21 17:37:29.000", "ended": "2025-01-21 20:25:06.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "b8d1f009000000000000", "Serial": "26663654", "Sec": 707960 } " 2025-02-09 14:25:28.879 - debug: kecontact.0 (17578) History ID received: 26 2025-02-09 14:25:29.176 - debug: kecontact.0 (17578) Sent "report 127" to 10.1.4.9:7090 2025-02-09 14:25:29.179 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "127", "Session ID": 332, "Curr HW": 32000, "E start": 51564861, "E pres": 501564, "started[s]": 1737302813, "ended[s]": 1737319566, "started": "2025-01-19 16:06:53.000", "ended": "2025-01-19 20:46:06.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "ae27517f000000000000", "Serial": "26663654", "Sec": 707961 } " 2025-02-09 14:25:29.180 - debug: kecontact.0 (17578) History ID received: 27 2025-02-09 14:25:29.477 - debug: kecontact.0 (17578) Sent "report 128" to 10.1.4.9:7090 2025-02-09 14:25:29.479 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "128", "Session ID": 331, "Curr HW": 32000, "E start": 51135071, "E pres": 429790, "started[s]": 1737233118, "ended[s]": 1737266682, "started": "2025-01-18 20:45:18.000", "ended": "2025-01-19 06:04:42.000", "reason": 1, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "17b0297b000000000000", "Serial": "26663654", "Sec": 707961 } " 2025-02-09 14:25:29.479 - debug: kecontact.0 (17578) History ID received: 28 2025-02-09 14:25:29.777 - debug: kecontact.0 (17578) Sent "report 129" to 10.1.4.9:7090 2025-02-09 14:25:29.779 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "129", "Session ID": 330, "Curr HW": 32000, "E start": 51135071, "E pres": 0, "started[s]": 1737007916, "ended[s]": 1737007928, "started": "2025-01-16 06:11:56.000", "ended": "2025-01-16 06:12:08.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "7864bd6d000000000000", "Serial": "26663654", "Sec": 707961 } " 2025-02-09 14:25:29.779 - debug: kecontact.0 (17578) History ID received: 29 2025-02-09 14:25:30.078 - debug: kecontact.0 (17578) Sent "report 130" to 10.1.4.9:7090 2025-02-09 14:25:30.080 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "130", "Session ID": 329, "Curr HW": 32000, "E start": 50674256, "E pres": 460815, "started[s]": 1736962116, "ended[s]": 1736977505, "started": "2025-01-15 17:28:36.000", "ended": "2025-01-15 21:45:05.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "ea87026b000000000000", "Serial": "26663654", "Sec": 707962 } " 2025-02-09 14:25:30.080 - debug: kecontact.0 (17578) History ID received: 30 2025-02-09 14:25:30.378 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:25:30.380 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 707962 } " 2025-02-09 14:25:30.678 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:25:30.680 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 637, "E total": 56270610, "Serial": "26663654", "Sec": 707962 } " 2025-02-09 14:25:30.801 - debug: kecontact.0 (17578) Available max power: 23005.2 2025-02-09 14:25:30.801 - debug: kecontact.0 (17578) power: 23005.2 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:25:30.802 - debug: kecontact.0 (17578) Available surplus: 4395.4 2025-02-09 14:25:30.802 - debug: kecontact.0 (17578) no switching to default phases because of minimum time between switching (stopCharging): Sun Feb 09 2025 14:23:46 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:25:30.803 - debug: kecontact.0 (17578) not enough power for charging ... 2025-02-09 14:25:30.978 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:25:30.980 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 637, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 707962 } " 2025-02-09 14:25:30.980 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:25:34.823 - info: kecontact.0 (17578) change pause status of wallbox from true to false 2025-02-09 14:25:34.823 - debug: kecontact.0 (17578) set automatic.pauseWallbox to false 2025-02-09 14:25:34.823 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:25:34.825 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 707966 } " 2025-02-09 14:25:35.123 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:25:35.125 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 637, "E total": 56270610, "Serial": "26663654", "Sec": 707967 } " 2025-02-09 14:25:35.234 - debug: kecontact.0 (17578) Available max power: 23007 2025-02-09 14:25:35.234 - debug: kecontact.0 (17578) power: 23007 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:25:35.234 - debug: kecontact.0 (17578) Available surplus: 4388.6 2025-02-09 14:25:35.234 - debug: kecontact.0 (17578) power: 4388.6 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 6000 2025-02-09 14:25:35.234 - debug: kecontact.0 (17578) power: 4388.6 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 19000 2025-02-09 14:25:35.234 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:25:35.235 - info: kecontact.0 (17578) (re)start charging with 6000mA 2025-02-09 14:25:35.423 - debug: kecontact.0 (17578) Sent "currtime 6000 1" to 10.1.4.9:7090 2025-02-09 14:25:35.424 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-OK :done " 2025-02-09 14:25:35.424 - debug: kecontact.0 (17578) Received TCH-OK :done 2025-02-09 14:25:35.722 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:25:35.724 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 637, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 707967 } " 2025-02-09 14:25:35.724 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:25:36.043 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:25:36.045 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 707968 } " 2025-02-09 14:25:36.344 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:25:36.346 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 637, "E total": 56270610, "Serial": "26663654", "Sec": 707968 } " 2025-02-09 14:25:36.430 - debug: kecontact.0 (17578) Available max power: 23031.85 2025-02-09 14:25:36.430 - debug: kecontact.0 (17578) power: 23031.85 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:25:36.431 - debug: kecontact.0 (17578) Available surplus: 4422.85 2025-02-09 14:25:36.474 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Enable sys": 1}" 2025-02-09 14:25:36.644 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:25:36.647 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 637, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 707968 } " 2025-02-09 14:25:36.649 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:25:38.747 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Max curr": 6000}" 2025-02-09 14:25:42.233 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"State": 2}" 2025-02-09 14:25:43.137 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"State": 3}" 2025-02-09 14:25:51.044 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:25:51.047 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 707983 } " 2025-02-09 14:25:51.345 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:25:51.347 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 236, "U2": 238, "U3": 235, "I1": 880, "I2": 284, "I3": 277, "P": 135131, "PF": 374, "E pres": 637, "E total": 56270610, "Serial": "26663654", "Sec": 707983 } " 2025-02-09 14:25:51.440 - debug: kecontact.0 (17578) Available max power: 23115.791 2025-02-09 14:25:51.440 - debug: kecontact.0 (17578) power: 23115.791 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 34000 2025-02-09 14:25:51.441 - debug: kecontact.0 (17578) Available surplus: 4483.291 2025-02-09 14:25:51.646 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:25:51.650 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 638, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 707983 } " 2025-02-09 14:25:51.651 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:26:06.044 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:26:06.047 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 707998 } " 2025-02-09 14:26:06.345 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:26:06.347 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 236, "U2": 237, "U3": 233, "I1": 6113, "I2": 6175, "I3": 6127, "P": 4304692, "PF": 991, "E pres": 724, "E total": 56270697, "Serial": "26663654", "Sec": 707998 } " 2025-02-09 14:26:06.491 - debug: kecontact.0 (17578) Available max power: 27589.092 2025-02-09 14:26:06.491 - debug: kecontact.0 (17578) power: 27589.092 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 40000 2025-02-09 14:26:06.491 - debug: kecontact.0 (17578) Available surplus: 5843.892 2025-02-09 14:26:06.491 - debug: kecontact.0 (17578) power: 5843.892 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 8000 2025-02-09 14:26:06.491 - debug: kecontact.0 (17578) power: 5843.892 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 25000 2025-02-09 14:26:06.491 - debug: kecontact.0 (17578) wallbox set to charging maximum of 8000 mA 2025-02-09 14:26:06.492 - info: kecontact.0 (17578) regulate wallbox from 6000 to 8000mA 2025-02-09 14:26:06.523 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 727}" 2025-02-09 14:26:06.645 - debug: kecontact.0 (17578) Sent "currtime 8000 1" to 10.1.4.9:7090 2025-02-09 14:26:06.648 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-OK :done " 2025-02-09 14:26:06.648 - debug: kecontact.0 (17578) Received TCH-OK :done 2025-02-09 14:26:06.946 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:26:06.948 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 730, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 707998 } " 2025-02-09 14:26:06.949 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:26:09.459 - debug: kecontact.0 (17578) set automatic.pauseWallbox to false 2025-02-09 14:26:13.250 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Max curr": 8000}" 2025-02-09 14:26:14.769 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 828}" 2025-02-09 14:26:21.044 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:26:21.046 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 8000, "Max curr %": 133, "Curr HW": 32000, "Curr user": 8000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 8000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708013 } " 2025-02-09 14:26:21.062 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 928}" 2025-02-09 14:26:21.344 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:26:21.347 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 236, "U2": 237, "U3": 233, "I1": 8071, "I2": 8139, "I3": 8119, "P": 5711417, "PF": 995, "E pres": 931, "E total": 56270904, "Serial": "26663654", "Sec": 708013 } " 2025-02-09 14:26:21.436 - info: kecontact.0 (17578) vehicle (re)starts to charge 2025-02-09 14:26:21.438 - debug: kecontact.0 (17578) Available max power: 28208.617 2025-02-09 14:26:21.438 - debug: kecontact.0 (17578) power: 28208.617 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 41000 2025-02-09 14:26:21.438 - debug: kecontact.0 (17578) Available surplus: 4290.617 2025-02-09 14:26:21.644 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:26:21.648 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 934, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708013 } " 2025-02-09 14:26:21.648 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:26:27.355 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 1027}" 2025-02-09 14:26:33.648 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 1127}" 2025-02-09 14:26:36.045 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:26:36.046 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 8000, "Max curr %": 133, "Curr HW": 32000, "Curr user": 8000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 8000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708028 } " 2025-02-09 14:26:36.345 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:26:36.348 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 236, "U2": 237, "U3": 232, "I1": 8099, "I2": 8176, "I3": 8141, "P": 5726551, "PF": 995, "E pres": 1169, "E total": 56271142, "Serial": "26663654", "Sec": 708028 } " 2025-02-09 14:26:36.439 - debug: kecontact.0 (17578) Available max power: 28233.451 2025-02-09 14:26:36.440 - debug: kecontact.0 (17578) power: 28233.451 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 41000 2025-02-09 14:26:36.440 - debug: kecontact.0 (17578) Available surplus: 4308.651 2025-02-09 14:26:36.440 - debug: kecontact.0 (17578) power: 4308.651 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 6000 2025-02-09 14:26:36.440 - debug: kecontact.0 (17578) power: 4308.651 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 19000 2025-02-09 14:26:36.440 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:26:36.440 - info: kecontact.0 (17578) regulate wallbox from 8000 to 6000mA 2025-02-09 14:26:36.645 - debug: kecontact.0 (17578) Sent "currtime 6000 1" to 10.1.4.9:7090 2025-02-09 14:26:36.647 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-OK :done " 2025-02-09 14:26:36.648 - debug: kecontact.0 (17578) Received TCH-OK :done 2025-02-09 14:26:36.945 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:26:36.947 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 1179, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708028 } " 2025-02-09 14:26:36.948 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:26:39.941 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 1227}" 2025-02-09 14:26:43.196 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Max curr": 6000}" 2025-02-09 14:26:47.319 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 1329}" 2025-02-09 14:26:51.046 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:26:51.049 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708043 } " 2025-02-09 14:26:51.346 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:26:51.349 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 237, "U2": 237, "U3": 234, "I1": 6119, "I2": 6173, "I3": 6144, "P": 4320879, "PF": 991, "E pres": 1376, "E total": 56271349, "Serial": "26663654", "Sec": 708043 } " 2025-02-09 14:26:51.438 - debug: kecontact.0 (17578) Available max power: 27478.989 2025-02-09 14:26:51.438 - debug: kecontact.0 (17578) power: 27478.989 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 40000 2025-02-09 14:26:51.438 - debug: kecontact.0 (17578) Available surplus: 4414.889 2025-02-09 14:26:51.646 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:26:51.649 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 1378, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708043 } " 2025-02-09 14:26:51.650 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:26:55.565 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 1427}" 2025-02-09 14:27:04.028 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 1529}" 2025-02-09 14:27:06.047 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:27:06.049 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708058 } " 2025-02-09 14:27:06.347 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:27:06.349 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 238, "U2": 237, "U3": 233, "I1": 6115, "I2": 6177, "I3": 6145, "P": 4323383, "PF": 991, "E pres": 1555, "E total": 56271528, "Serial": "26663654", "Sec": 708058 } " 2025-02-09 14:27:06.504 - debug: kecontact.0 (17578) Available max power: 27314.362999999998 2025-02-09 14:27:06.505 - debug: kecontact.0 (17578) power: 27314.362999999998 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 40000 2025-02-09 14:27:06.505 - debug: kecontact.0 (17578) Available surplus: 4398.063 2025-02-09 14:27:06.505 - debug: kecontact.0 (17578) power: 4398.063 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 6000 2025-02-09 14:27:06.505 - debug: kecontact.0 (17578) power: 4398.063 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 19000 2025-02-09 14:27:06.505 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:27:06.647 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:27:06.651 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 1561, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708058 } " 2025-02-09 14:27:06.651 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:27:12.274 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 1628}" 2025-02-09 14:27:20.519 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 1727}" 2025-02-09 14:27:21.048 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:27:21.050 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708073 } " 2025-02-09 14:27:21.348 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:27:21.351 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 236, "U2": 237, "U3": 233, "I1": 6110, "I2": 6176, "I3": 6129, "P": 4313681, "PF": 992, "E pres": 1734, "E total": 56271707, "Serial": "26663654", "Sec": 708073 } " 2025-02-09 14:27:21.427 - debug: kecontact.0 (17578) Available max power: 27311.621 2025-02-09 14:27:21.427 - debug: kecontact.0 (17578) power: 27311.621 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 40000 2025-02-09 14:27:21.427 - debug: kecontact.0 (17578) Available surplus: 4296.321 2025-02-09 14:27:21.649 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:27:21.651 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 1740, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708073 } " 2025-02-09 14:27:21.651 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:27:28.983 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 1828}" 2025-02-09 14:27:36.048 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:27:36.050 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708088 } " 2025-02-09 14:27:36.348 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:27:36.349 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 237, "U2": 237, "U3": 233, "I1": 6114, "I2": 6178, "I3": 6131, "P": 4311460, "PF": 991, "E pres": 1915, "E total": 56271888, "Serial": "26663654", "Sec": 708088 } " 2025-02-09 14:27:36.439 - debug: kecontact.0 (17578) Available max power: 27319.89 2025-02-09 14:27:36.439 - debug: kecontact.0 (17578) power: 27319.89 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 40000 2025-02-09 14:27:36.440 - debug: kecontact.0 (17578) Available surplus: 4260.19 2025-02-09 14:27:36.440 - debug: kecontact.0 (17578) power: 4260.19 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 6000 2025-02-09 14:27:36.440 - debug: kecontact.0 (17578) power: 4260.19 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 19000 2025-02-09 14:27:36.440 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:27:36.648 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:27:36.651 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 1919, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708088 } " 2025-02-09 14:27:36.652 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:27:37.229 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 1927}" 2025-02-09 14:27:45.475 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 2027}" 2025-02-09 14:27:51.048 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:27:51.050 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708103 } " 2025-02-09 14:27:51.348 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:27:51.349 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 236, "U2": 237, "U3": 234, "I1": 6115, "I2": 6175, "I3": 6142, "P": 4317636, "PF": 991, "E pres": 2096, "E total": 56272069, "Serial": "26663654", "Sec": 708103 } " 2025-02-09 14:27:51.434 - debug: kecontact.0 (17578) Available max power: 27300.596 2025-02-09 14:27:51.434 - debug: kecontact.0 (17578) power: 27300.596 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 40000 2025-02-09 14:27:51.434 - debug: kecontact.0 (17578) Available surplus: 4084.1960000000004 2025-02-09 14:27:51.648 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:27:51.651 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 2099, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708103 } " 2025-02-09 14:27:51.652 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:27:53.938 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 2128}" 2025-02-09 14:28:02.184 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 2227}" 2025-02-09 14:28:06.048 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:28:06.050 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708118 } " 2025-02-09 14:28:06.348 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:28:06.350 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 236, "U2": 237, "U3": 234, "I1": 6108, "I2": 6173, "I3": 6144, "P": 4314991, "PF": 991, "E pres": 2277, "E total": 56272250, "Serial": "26663654", "Sec": 708118 } " 2025-02-09 14:28:06.429 - debug: kecontact.0 (17578) Available max power: 27283.141 2025-02-09 14:28:06.429 - debug: kecontact.0 (17578) power: 27283.141 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 40000 2025-02-09 14:28:06.429 - debug: kecontact.0 (17578) Available surplus: 3938.841 2025-02-09 14:28:06.429 - debug: kecontact.0 (17578) power: 3938.841 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 6000 2025-02-09 14:28:06.429 - debug: kecontact.0 (17578) power: 3938.841 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 17000 2025-02-09 14:28:06.429 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:28:06.647 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:28:06.649 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 2279, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708118 } " 2025-02-09 14:28:06.649 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:28:10.647 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 2328}" 2025-02-09 14:28:18.894 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 2428}" 2025-02-09 14:28:21.048 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:28:21.051 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708133 } " 2025-02-09 14:28:21.348 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:28:21.351 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 235, "U2": 237, "U3": 234, "I1": 6122, "I2": 6178, "I3": 6138, "P": 4312320, "PF": 992, "E pres": 2456, "E total": 56272429, "Serial": "26663654", "Sec": 708133 } " 2025-02-09 14:28:21.440 - debug: kecontact.0 (17578) Available max power: 27293.09 2025-02-09 14:28:21.441 - debug: kecontact.0 (17578) power: 27293.09 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 40000 2025-02-09 14:28:21.441 - debug: kecontact.0 (17578) Available surplus: 3631.6899999999996 2025-02-09 14:28:21.648 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:28:21.651 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 2458, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708133 } " 2025-02-09 14:28:21.652 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:28:27.356 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 2529}" 2025-02-09 14:28:35.602 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 2627}" 2025-02-09 14:28:36.048 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:28:36.051 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708148 } " 2025-02-09 14:28:36.348 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:28:36.351 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 234, "U2": 237, "U3": 235, "I1": 6105, "I2": 6175, "I3": 6140, "P": 4305321, "PF": 991, "E pres": 2636, "E total": 56272609, "Serial": "26663654", "Sec": 708148 } " 2025-02-09 14:28:36.443 - debug: kecontact.0 (17578) Available max power: 27247.361 2025-02-09 14:28:36.443 - debug: kecontact.0 (17578) power: 27247.361 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 39000 2025-02-09 14:28:36.443 - debug: kecontact.0 (17578) Available surplus: 3326.661 2025-02-09 14:28:36.443 - debug: kecontact.0 (17578) power: 3326.661 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 5000 2025-02-09 14:28:36.443 - debug: kecontact.0 (17578) power: 3326.661 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 14000 2025-02-09 14:28:36.444 - debug: kecontact.0 (17578) no switching to 1 phase because of minimum charging time: Sun Feb 09 2025 14:26:21 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:28:36.444 - debug: kecontact.0 (17578) check with additional power of: 250 2025-02-09 14:28:36.444 - debug: kecontact.0 (17578) power: 3576.661 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 5000 2025-02-09 14:28:36.444 - debug: kecontact.0 (17578) check with additional power of: 250 and underUsage: 500 2025-02-09 14:28:36.444 - debug: kecontact.0 (17578) power: 4076.661 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 6000 2025-02-09 14:28:36.444 - info: kecontact.0 (17578) tolerated under-usage of charge power, continuing charging session 2025-02-09 14:28:36.444 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:28:36.648 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:28:36.651 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 2637, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708148 } " 2025-02-09 14:28:36.651 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:28:44.065 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 2729}" 2025-02-09 14:28:51.048 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:28:51.050 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708163 } " 2025-02-09 14:28:51.349 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:28:51.351 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 235, "U2": 236, "U3": 235, "I1": 6057, "I2": 6121, "I3": 6076, "P": 4258000, "PF": 991, "E pres": 2814, "E total": 56272787, "Serial": "26663654", "Sec": 708163 } " 2025-02-09 14:28:51.437 - debug: kecontact.0 (17578) Available max power: 26956.07 2025-02-09 14:28:51.437 - debug: kecontact.0 (17578) power: 26956.07 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 39000 2025-02-09 14:28:51.437 - debug: kecontact.0 (17578) Available surplus: 3033.17 2025-02-09 14:28:51.649 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:28:51.651 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 2817, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708163 } " 2025-02-09 14:28:51.652 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:28:52.311 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 2827}" 2025-02-09 14:29:00.774 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 2928}" 2025-02-09 14:29:06.048 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:29:06.051 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708178 } " 2025-02-09 14:29:06.349 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:29:06.350 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 235, "U2": 235, "U3": 235, "I1": 6042, "I2": 6107, "I3": 6093, "P": 4263496, "PF": 991, "E pres": 2991, "E total": 56272964, "Serial": "26663654", "Sec": 708178 } " 2025-02-09 14:29:06.435 - debug: kecontact.0 (17578) Available max power: 26650.096 2025-02-09 14:29:06.435 - debug: kecontact.0 (17578) power: 26650.096 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 39000 2025-02-09 14:29:06.435 - debug: kecontact.0 (17578) Available surplus: 2729.896 2025-02-09 14:29:06.435 - debug: kecontact.0 (17578) power: 2729.896 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 4000 2025-02-09 14:29:06.435 - debug: kecontact.0 (17578) power: 2729.896 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 12000 2025-02-09 14:29:06.435 - debug: kecontact.0 (17578) no switching to 1 phase because of minimum charging time: Sun Feb 09 2025 14:26:21 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:29:06.435 - debug: kecontact.0 (17578) check with additional power of: 250 2025-02-09 14:29:06.435 - debug: kecontact.0 (17578) power: 2979.896 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 4000 2025-02-09 14:29:06.435 - debug: kecontact.0 (17578) check with additional power of: 250 and underUsage: 500 2025-02-09 14:29:06.435 - debug: kecontact.0 (17578) power: 3479.896 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 5000 2025-02-09 14:29:06.436 - info: kecontact.0 (17578) minimum charge time of 300sec not reached, continuing charging session. Sun Feb 09 2025 14:26:21 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:29:06.436 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:29:06.649 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:29:06.652 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 2997, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708178 } " 2025-02-09 14:29:06.652 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:29:09.237 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 3027}" 2025-02-09 14:29:17.700 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 3129}" 2025-02-09 14:29:21.048 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:29:21.051 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708193 } " 2025-02-09 14:29:21.350 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:29:21.352 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 235, "U2": 235, "U3": 235, "I1": 6117, "I2": 6177, "I3": 6111, "P": 4279458, "PF": 992, "E pres": 3170, "E total": 56273143, "Serial": "26663654", "Sec": 708193 } " 2025-02-09 14:29:21.440 - debug: kecontact.0 (17578) Available max power: 26330.958 2025-02-09 14:29:21.440 - debug: kecontact.0 (17578) power: 26330.958 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 38000 2025-02-09 14:29:21.440 - debug: kecontact.0 (17578) Available surplus: 2408.0579999999995 2025-02-09 14:29:21.650 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:29:21.652 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 3175, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708193 } " 2025-02-09 14:29:21.652 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:29:25.946 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 3227}" 2025-02-09 14:29:34.412 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 3327}" 2025-02-09 14:29:36.050 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:29:36.051 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708208 } " 2025-02-09 14:29:36.350 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:29:36.352 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 233, "U2": 236, "U3": 234, "I1": 6040, "I2": 6111, "I3": 6069, "P": 4242558, "PF": 991, "E pres": 3348, "E total": 56273321, "Serial": "26663654", "Sec": 708208 } " 2025-02-09 14:29:36.454 - debug: kecontact.0 (17578) Available max power: 25975.958 2025-02-09 14:29:36.454 - debug: kecontact.0 (17578) power: 25975.958 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 38000 2025-02-09 14:29:36.454 - debug: kecontact.0 (17578) Available surplus: 2055.758 2025-02-09 14:29:36.454 - debug: kecontact.0 (17578) power: 2055.758 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 3000 2025-02-09 14:29:36.454 - debug: kecontact.0 (17578) power: 2055.758 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 9000 2025-02-09 14:29:36.454 - debug: kecontact.0 (17578) no switching to 1 phase because of minimum charging time: Sun Feb 09 2025 14:26:21 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:29:36.454 - debug: kecontact.0 (17578) check with additional power of: 250 2025-02-09 14:29:36.454 - debug: kecontact.0 (17578) power: 2305.758 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 3000 2025-02-09 14:29:36.454 - debug: kecontact.0 (17578) check with additional power of: 250 and underUsage: 500 2025-02-09 14:29:36.454 - debug: kecontact.0 (17578) power: 2805.758 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 4000 2025-02-09 14:29:36.454 - info: kecontact.0 (17578) minimum charge time of 300sec not reached, continuing charging session. Sun Feb 09 2025 14:26:21 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:29:36.455 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:29:36.651 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:29:36.653 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 3352, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708208 } " 2025-02-09 14:29:36.653 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:29:42.872 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 3428}" 2025-02-09 14:29:51.050 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:29:51.053 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708223 } " 2025-02-09 14:29:51.118 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 3527}" 2025-02-09 14:29:51.350 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:29:51.351 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 232, "U2": 236, "U3": 235, "I1": 6117, "I2": 6175, "I3": 6136, "P": 4290220, "PF": 991, "E pres": 3527, "E total": 56273500, "Serial": "26663654", "Sec": 708223 } " 2025-02-09 14:29:51.489 - debug: kecontact.0 (17578) Available max power: 25885.72 2025-02-09 14:29:51.489 - debug: kecontact.0 (17578) power: 25885.72 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 38000 2025-02-09 14:29:51.489 - debug: kecontact.0 (17578) Available surplus: 1963.0200000000004 2025-02-09 14:29:51.650 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:29:51.653 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 3530, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708223 } " 2025-02-09 14:29:51.653 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:29:59.581 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 3627}" 2025-02-09 14:30:06.051 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:30:06.055 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708238 } " 2025-02-09 14:30:06.351 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:30:06.354 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 232, "U2": 236, "U3": 235, "I1": 6114, "I2": 6173, "I3": 6135, "P": 4289314, "PF": 991, "E pres": 3707, "E total": 56273680, "Serial": "26663654", "Sec": 708238 } " 2025-02-09 14:30:06.433 - debug: kecontact.0 (17578) Available max power: 25957.414 2025-02-09 14:30:06.433 - debug: kecontact.0 (17578) power: 25957.414 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 38000 2025-02-09 14:30:06.433 - debug: kecontact.0 (17578) Available surplus: 2037.9140000000002 2025-02-09 14:30:06.433 - debug: kecontact.0 (17578) power: 2037.9140000000002 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 3000 2025-02-09 14:30:06.433 - debug: kecontact.0 (17578) power: 2037.9140000000002 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 9000 2025-02-09 14:30:06.433 - debug: kecontact.0 (17578) no switching to 1 phase because of minimum charging time: Sun Feb 09 2025 14:26:21 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:30:06.433 - debug: kecontact.0 (17578) check with additional power of: 250 2025-02-09 14:30:06.433 - debug: kecontact.0 (17578) power: 2287.914 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 3000 2025-02-09 14:30:06.433 - debug: kecontact.0 (17578) check with additional power of: 250 and underUsage: 500 2025-02-09 14:30:06.433 - debug: kecontact.0 (17578) power: 2787.914 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 4000 2025-02-09 14:30:06.433 - info: kecontact.0 (17578) minimum charge time of 300sec not reached, continuing charging session. Sun Feb 09 2025 14:26:21 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:30:06.434 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:30:06.652 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:30:06.654 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 3709, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708238 } " 2025-02-09 14:30:06.654 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:30:08.044 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 3728}" 2025-02-09 14:30:16.507 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 3829}" 2025-02-09 14:30:21.052 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:30:21.054 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708253 } " 2025-02-09 14:30:21.352 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:30:21.354 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 233, "U2": 236, "U3": 234, "I1": 6112, "I2": 6174, "I3": 6143, "P": 4290547, "PF": 991, "E pres": 3886, "E total": 56273859, "Serial": "26663654", "Sec": 708253 } " 2025-02-09 14:30:21.446 - debug: kecontact.0 (17578) Available max power: 25942.747 2025-02-09 14:30:21.446 - debug: kecontact.0 (17578) power: 25942.747 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 38000 2025-02-09 14:30:21.446 - debug: kecontact.0 (17578) Available surplus: 2021.7469999999994 2025-02-09 14:30:21.652 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:30:21.654 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 3889, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708253 } " 2025-02-09 14:30:21.654 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:30:24.753 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 3927}" 2025-02-09 14:30:33.217 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 4028}" 2025-02-09 14:30:36.052 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:30:36.054 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708268 } " 2025-02-09 14:30:36.352 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:30:36.355 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 233, "U2": 235, "U3": 233, "I1": 6071, "I2": 6138, "I3": 6101, "P": 4254347, "PF": 991, "E pres": 4064, "E total": 56274037, "Serial": "26663654", "Sec": 708268 } " 2025-02-09 14:30:36.446 - debug: kecontact.0 (17578) Available max power: 25838.447 2025-02-09 14:30:36.446 - debug: kecontact.0 (17578) power: 25838.447 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 37000 2025-02-09 14:30:36.446 - debug: kecontact.0 (17578) Available surplus: 1918.3469999999998 2025-02-09 14:30:36.446 - debug: kecontact.0 (17578) power: 1918.3469999999998 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 3000 2025-02-09 14:30:36.447 - debug: kecontact.0 (17578) power: 1918.3469999999998 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 8000 2025-02-09 14:30:36.447 - debug: kecontact.0 (17578) no switching to 1 phase because of minimum charging time: Sun Feb 09 2025 14:26:21 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:30:36.447 - debug: kecontact.0 (17578) check with additional power of: 250 2025-02-09 14:30:36.447 - debug: kecontact.0 (17578) power: 2168.3469999999998 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 3000 2025-02-09 14:30:36.447 - debug: kecontact.0 (17578) check with additional power of: 250 and underUsage: 500 2025-02-09 14:30:36.447 - debug: kecontact.0 (17578) power: 2668.3469999999998 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 4000 2025-02-09 14:30:36.447 - info: kecontact.0 (17578) minimum charge time of 300sec not reached, continuing charging session. Sun Feb 09 2025 14:26:21 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:30:36.447 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:30:36.652 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:30:36.655 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 4067, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708268 } " 2025-02-09 14:30:36.659 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:30:41.679 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 4127}" 2025-02-09 14:30:50.143 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 4228}" 2025-02-09 14:30:51.052 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:30:51.054 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708283 } " 2025-02-09 14:30:51.353 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:30:51.355 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 233, "U2": 235, "U3": 234, "I1": 6071, "I2": 6128, "I3": 6092, "P": 4262219, "PF": 991, "E pres": 4240, "E total": 56274213, "Serial": "26663654", "Sec": 708283 } " 2025-02-09 14:30:51.436 - debug: kecontact.0 (17578) Available max power: 25815.319 2025-02-09 14:30:51.436 - debug: kecontact.0 (17578) power: 25815.319 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 37000 2025-02-09 14:30:51.436 - debug: kecontact.0 (17578) Available surplus: 1892.719 2025-02-09 14:30:51.653 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:30:51.655 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 4246, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708283 } " 2025-02-09 14:30:51.656 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:30:58.606 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 4328}" 2025-02-09 14:31:06.052 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:31:06.054 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708298 } " 2025-02-09 14:31:06.352 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:31:06.354 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 233, "U2": 236, "U3": 233, "I1": 6110, "I2": 6175, "I3": 6141, "P": 4290008, "PF": 992, "E pres": 4418, "E total": 56274391, "Serial": "26663654", "Sec": 708298 } " 2025-02-09 14:31:06.446 - debug: kecontact.0 (17578) Available max power: 25787.408 2025-02-09 14:31:06.446 - debug: kecontact.0 (17578) power: 25787.408 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 37000 2025-02-09 14:31:06.446 - debug: kecontact.0 (17578) Available surplus: 1864.7079999999996 2025-02-09 14:31:06.447 - debug: kecontact.0 (17578) power: 1864.7079999999996 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 3000 2025-02-09 14:31:06.447 - debug: kecontact.0 (17578) power: 1864.7079999999996 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 8000 2025-02-09 14:31:06.447 - debug: kecontact.0 (17578) no switching to 1 phase because of minimum charging time: Sun Feb 09 2025 14:26:21 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:31:06.447 - debug: kecontact.0 (17578) check with additional power of: 250 2025-02-09 14:31:06.447 - debug: kecontact.0 (17578) power: 2114.7079999999996 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 3000 2025-02-09 14:31:06.447 - debug: kecontact.0 (17578) check with additional power of: 250 and underUsage: 500 2025-02-09 14:31:06.447 - debug: kecontact.0 (17578) power: 2614.7079999999996 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 4000 2025-02-09 14:31:06.447 - info: kecontact.0 (17578) minimum charge time of 300sec not reached, continuing charging session. Sun Feb 09 2025 14:26:21 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:31:06.447 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:31:06.652 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:31:06.655 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 4423, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708298 } " 2025-02-09 14:31:06.655 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:31:07.069 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 4428}" 2025-02-09 14:31:15.315 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 4527}" 2025-02-09 14:31:21.052 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:31:21.055 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708313 } " 2025-02-09 14:31:21.352 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:31:21.355 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 232, "U2": 236, "U3": 235, "I1": 6045, "I2": 6111, "I3": 6073, "P": 4244940, "PF": 992, "E pres": 4595, "E total": 56274568, "Serial": "26663654", "Sec": 708313 } " 2025-02-09 14:31:21.449 - debug: kecontact.0 (17578) Available max power: 25730.34 2025-02-09 14:31:21.449 - debug: kecontact.0 (17578) power: 25730.34 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 37000 2025-02-09 14:31:21.449 - debug: kecontact.0 (17578) Available surplus: 1806.7399999999998 2025-02-09 14:31:21.652 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:31:21.653 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 4601, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708313 } " 2025-02-09 14:31:21.654 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:31:23.994 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 4628}" 2025-02-09 14:31:32.241 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 4727}" 2025-02-09 14:31:36.052 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:31:36.053 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708328 } " 2025-02-09 14:31:36.352 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:31:36.354 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 232, "U2": 236, "U3": 235, "I1": 6059, "I2": 6130, "I3": 6098, "P": 4258604, "PF": 991, "E pres": 4773, "E total": 56274746, "Serial": "26663654", "Sec": 708328 } " 2025-02-09 14:31:36.436 - debug: kecontact.0 (17578) Available max power: 25724.004 2025-02-09 14:31:36.436 - debug: kecontact.0 (17578) power: 25724.004 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 37000 2025-02-09 14:31:36.436 - debug: kecontact.0 (17578) Available surplus: 1802.304 2025-02-09 14:31:36.436 - debug: kecontact.0 (17578) power: 1802.304 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 3000 2025-02-09 14:31:36.436 - debug: kecontact.0 (17578) power: 1802.304 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 8000 2025-02-09 14:31:36.437 - debug: kecontact.0 (17578) no switching to 1 phase because of minimum regard time: null 2025-02-09 14:31:36.437 - debug: kecontact.0 (17578) check with additional power of: 250 2025-02-09 14:31:36.437 - debug: kecontact.0 (17578) power: 2052.304 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 3000 2025-02-09 14:31:36.437 - debug: kecontact.0 (17578) check with additional power of: 250 and underUsage: 500 2025-02-09 14:31:36.437 - debug: kecontact.0 (17578) power: 2552.304 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 4000 2025-02-09 14:31:36.437 - info: kecontact.0 (17578) minimum regard time of 180sec not reached, continuing charging session. RegardTimestamp: null 2025-02-09 14:31:36.437 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:31:36.652 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:31:36.655 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 4779, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708328 } " 2025-02-09 14:31:36.655 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:31:40.704 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 4827}" 2025-02-09 14:31:49.167 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 4927}" 2025-02-09 14:31:51.052 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:31:51.055 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708343 } " 2025-02-09 14:31:51.352 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:31:51.353 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 233, "U2": 236, "U3": 235, "I1": 6108, "I2": 6178, "I3": 6140, "P": 4293757, "PF": 991, "E pres": 4953, "E total": 56274926, "Serial": "26663654", "Sec": 708343 } " 2025-02-09 14:31:51.437 - debug: kecontact.0 (17578) Available max power: 25781.057 2025-02-09 14:31:51.437 - debug: kecontact.0 (17578) power: 25781.057 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 37000 2025-02-09 14:31:51.437 - debug: kecontact.0 (17578) Available surplus: 1857.8569999999995 2025-02-09 14:31:51.652 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:31:51.654 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 4955, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708343 } " 2025-02-09 14:31:51.654 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:31:57.630 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 5029}" 2025-02-09 14:32:06.052 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:32:06.054 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708358 } " 2025-02-09 14:32:06.093 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 5129}" 2025-02-09 14:32:06.352 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:32:06.354 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 233, "U2": 235, "U3": 234, "I1": 6060, "I2": 6129, "I3": 6092, "P": 4253422, "PF": 991, "E pres": 5132, "E total": 56275105, "Serial": "26663654", "Sec": 708358 } " 2025-02-09 14:32:06.439 - debug: kecontact.0 (17578) Available max power: 25648.722 2025-02-09 14:32:06.439 - debug: kecontact.0 (17578) power: 25648.722 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 37000 2025-02-09 14:32:06.439 - debug: kecontact.0 (17578) Available surplus: 1726.8219999999997 2025-02-09 14:32:06.439 - debug: kecontact.0 (17578) power: 1726.8219999999997 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 3000 2025-02-09 14:32:06.439 - debug: kecontact.0 (17578) power: 1726.8219999999997 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 8000 2025-02-09 14:32:06.439 - debug: kecontact.0 (17578) no switching to 1 phase because of minimum regard time: Sun Feb 09 2025 14:31:36 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:32:06.440 - debug: kecontact.0 (17578) check with additional power of: 250 2025-02-09 14:32:06.440 - debug: kecontact.0 (17578) power: 1976.8219999999997 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 3000 2025-02-09 14:32:06.440 - debug: kecontact.0 (17578) check with additional power of: 250 and underUsage: 500 2025-02-09 14:32:06.440 - debug: kecontact.0 (17578) power: 2476.8219999999997 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 4000 2025-02-09 14:32:06.440 - info: kecontact.0 (17578) minimum regard time of 180sec not reached, continuing charging session. RegardTimestamp: Sun Feb 09 2025 14:31:36 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:32:06.440 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:32:06.652 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:32:06.654 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 5133, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708358 } " 2025-02-09 14:32:06.655 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:32:14.339 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 5227}" 2025-02-09 14:32:21.052 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:32:21.054 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708373 } " 2025-02-09 14:32:21.352 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:32:21.353 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 232, "U2": 235, "U3": 234, "I1": 6042, "I2": 6100, "I3": 6130, "P": 4268055, "PF": 992, "E pres": 5308, "E total": 56275281, "Serial": "26663654", "Sec": 708373 } " 2025-02-09 14:32:21.454 - debug: kecontact.0 (17578) Available max power: 25557.155 2025-02-09 14:32:21.454 - debug: kecontact.0 (17578) power: 25557.155 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 37000 2025-02-09 14:32:21.454 - debug: kecontact.0 (17578) Available surplus: 1637.1550000000002 2025-02-09 14:32:21.652 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:32:21.654 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 5311, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708373 } " 2025-02-09 14:32:21.655 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:32:23.018 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 5329}" 2025-02-09 14:32:31.264 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 5427}" 2025-02-09 14:32:36.051 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:32:36.054 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708388 } " 2025-02-09 14:32:36.352 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:32:36.355 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 230, "U2": 236, "U3": 235, "I1": 6054, "I2": 6128, "I3": 6094, "P": 4238744, "PF": 991, "E pres": 5485, "E total": 56275458, "Serial": "26663654", "Sec": 708388 } " 2025-02-09 14:32:36.441 - debug: kecontact.0 (17578) Available max power: 25419.144 2025-02-09 14:32:36.441 - debug: kecontact.0 (17578) power: 25419.144 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 37000 2025-02-09 14:32:36.441 - debug: kecontact.0 (17578) Available surplus: 1496.7439999999997 2025-02-09 14:32:36.441 - debug: kecontact.0 (17578) power: 1496.7439999999997 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 2000 2025-02-09 14:32:36.441 - debug: kecontact.0 (17578) power: 1496.7439999999997 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 7000 2025-02-09 14:32:36.441 - debug: kecontact.0 (17578) no switching to 1 phase because of minimum regard time: Sun Feb 09 2025 14:31:36 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:32:36.441 - debug: kecontact.0 (17578) check with additional power of: 250 2025-02-09 14:32:36.441 - debug: kecontact.0 (17578) power: 1746.7439999999997 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 3000 2025-02-09 14:32:36.441 - debug: kecontact.0 (17578) check with additional power of: 250 and underUsage: 500 2025-02-09 14:32:36.441 - debug: kecontact.0 (17578) power: 2246.7439999999997 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 3000 2025-02-09 14:32:36.441 - info: kecontact.0 (17578) minimum regard time of 180sec not reached, continuing charging session. RegardTimestamp: Sun Feb 09 2025 14:31:36 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:32:36.441 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:32:36.652 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:32:36.654 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 5488, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708388 } " 2025-02-09 14:32:36.654 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:32:39.944 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 5529}" 2025-02-09 14:32:48.407 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 5629}" 2025-02-09 14:32:51.052 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:32:51.054 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708403 } " 2025-02-09 14:32:51.352 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:32:51.353 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 231, "U2": 236, "U3": 233, "I1": 6052, "I2": 6131, "I3": 6088, "P": 4234173, "PF": 992, "E pres": 5662, "E total": 56275635, "Serial": "26663654", "Sec": 708403 } " 2025-02-09 14:32:51.487 - debug: kecontact.0 (17578) Available max power: 25300.873 2025-02-09 14:32:51.487 - debug: kecontact.0 (17578) power: 25300.873 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 37000 2025-02-09 14:32:51.488 - debug: kecontact.0 (17578) Available surplus: 1377.5729999999999 2025-02-09 14:32:51.652 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:32:51.654 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 5665, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708403 } " 2025-02-09 14:32:51.657 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:32:56.871 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 5729}" 2025-02-09 14:33:05.334 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 5829}" 2025-02-09 14:33:06.052 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:33:06.055 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708418 } " 2025-02-09 14:33:06.353 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:33:06.356 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 232, "U2": 234, "U3": 232, "I1": 6053, "I2": 6115, "I3": 6071, "P": 4218808, "PF": 991, "E pres": 5839, "E total": 56275812, "Serial": "26663654", "Sec": 708418 } " 2025-02-09 14:33:06.440 - debug: kecontact.0 (17578) Available max power: 25188.308 2025-02-09 14:33:06.440 - debug: kecontact.0 (17578) power: 25188.308 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 37000 2025-02-09 14:33:06.440 - debug: kecontact.0 (17578) Available surplus: 1269.708 2025-02-09 14:33:06.440 - debug: kecontact.0 (17578) power: 1269.708 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 2000 2025-02-09 14:33:06.440 - debug: kecontact.0 (17578) power: 1269.708 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 6000 2025-02-09 14:33:06.440 - debug: kecontact.0 (17578) no switching to 1 phase because of minimum regard time: Sun Feb 09 2025 14:31:36 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:33:06.441 - debug: kecontact.0 (17578) check with additional power of: 250 2025-02-09 14:33:06.441 - debug: kecontact.0 (17578) power: 1519.708 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 2000 2025-02-09 14:33:06.441 - debug: kecontact.0 (17578) check with additional power of: 250 and underUsage: 500 2025-02-09 14:33:06.441 - debug: kecontact.0 (17578) power: 2019.708 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 3000 2025-02-09 14:33:06.441 - info: kecontact.0 (17578) minimum regard time of 180sec not reached, continuing charging session. RegardTimestamp: Sun Feb 09 2025 14:31:36 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:33:06.441 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:33:06.653 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:33:06.656 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 5844, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708418 } " 2025-02-09 14:33:06.656 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:33:13.797 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 5929}" 2025-02-09 14:33:21.053 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:33:21.056 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708433 } " 2025-02-09 14:33:21.354 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:33:21.356 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 232, "U2": 234, "U3": 231, "I1": 6088, "I2": 6155, "I3": 6118, "P": 4242590, "PF": 991, "E pres": 6016, "E total": 56275989, "Serial": "26663654", "Sec": 708433 } " 2025-02-09 14:33:21.443 - debug: kecontact.0 (17578) Available max power: 25109.49 2025-02-09 14:33:21.443 - debug: kecontact.0 (17578) power: 25109.49 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 36000 2025-02-09 14:33:21.443 - debug: kecontact.0 (17578) Available surplus: 1186.3900000000003 2025-02-09 14:33:21.655 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:33:21.658 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 6021, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708433 } " 2025-02-09 14:33:21.659 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:33:22.263 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 6028}" 2025-02-09 14:33:30.723 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 6128}" 2025-02-09 14:33:36.053 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:33:36.056 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708448 } " 2025-02-09 14:33:36.353 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:33:36.356 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 231, "U2": 233, "U3": 231, "I1": 6061, "I2": 6119, "I3": 6076, "P": 4207604, "PF": 992, "E pres": 6191, "E total": 56276164, "Serial": "26663654", "Sec": 708448 } " 2025-02-09 14:33:36.449 - debug: kecontact.0 (17578) Available max power: 25040.004 2025-02-09 14:33:36.449 - debug: kecontact.0 (17578) power: 25040.004 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 36000 2025-02-09 14:33:36.449 - debug: kecontact.0 (17578) Available surplus: 1117.9040000000005 2025-02-09 14:33:36.449 - debug: kecontact.0 (17578) power: 1117.9040000000005 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 2000 2025-02-09 14:33:36.449 - debug: kecontact.0 (17578) power: 1117.9040000000005 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 5000 2025-02-09 14:33:36.449 - debug: kecontact.0 (17578) no switching to 1 phase because of minimum regard time: Sun Feb 09 2025 14:31:36 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:33:36.449 - debug: kecontact.0 (17578) check with additional power of: 250 2025-02-09 14:33:36.449 - debug: kecontact.0 (17578) power: 1367.9040000000005 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 2000 2025-02-09 14:33:36.449 - debug: kecontact.0 (17578) check with additional power of: 250 and underUsage: 500 2025-02-09 14:33:36.450 - debug: kecontact.0 (17578) power: 1867.9040000000005 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 3000 2025-02-09 14:33:36.450 - info: kecontact.0 (17578) minimum regard time of 180sec not reached, continuing charging session. RegardTimestamp: Sun Feb 09 2025 14:31:36 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:33:36.450 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:33:36.653 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:33:36.656 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 6196, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708448 } " 2025-02-09 14:33:36.656 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:33:39.403 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 6229}" 2025-02-09 14:33:47.866 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 6329}" 2025-02-09 14:33:51.053 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:33:51.054 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708463 } " 2025-02-09 14:33:51.353 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:33:51.356 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 231, "U2": 234, "U3": 231, "I1": 6085, "I2": 6145, "I3": 6106, "P": 4222892, "PF": 992, "E pres": 6369, "E total": 56276342, "Serial": "26663654", "Sec": 708463 } " 2025-02-09 14:33:51.452 - debug: kecontact.0 (17578) Available max power: 25049.092 2025-02-09 14:33:51.452 - debug: kecontact.0 (17578) power: 25049.092 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 36000 2025-02-09 14:33:51.453 - debug: kecontact.0 (17578) Available surplus: 1125.7919999999995 2025-02-09 14:33:51.653 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:33:51.654 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 6371, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708463 } " 2025-02-09 14:33:51.655 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:33:56.329 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 6428}" 2025-02-09 14:34:04.792 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 6528}" 2025-02-09 14:34:06.053 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:34:06.055 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708478 } " 2025-02-09 14:34:06.354 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:34:06.356 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 231, "U2": 233, "U3": 232, "I1": 6102, "I2": 6170, "I3": 6137, "P": 4242629, "PF": 992, "E pres": 6546, "E total": 56276519, "Serial": "26663654", "Sec": 708478 } " 2025-02-09 14:34:06.442 - debug: kecontact.0 (17578) Available max power: 25057.029 2025-02-09 14:34:06.443 - debug: kecontact.0 (17578) power: 25057.029 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 36000 2025-02-09 14:34:06.443 - debug: kecontact.0 (17578) Available surplus: 1136.3289999999997 2025-02-09 14:34:06.443 - debug: kecontact.0 (17578) power: 1136.3289999999997 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 2000 2025-02-09 14:34:06.443 - debug: kecontact.0 (17578) power: 1136.3289999999997 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 5000 2025-02-09 14:34:06.443 - debug: kecontact.0 (17578) no switching to 1 phase because of minimum regard time: Sun Feb 09 2025 14:31:36 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:34:06.443 - debug: kecontact.0 (17578) check with additional power of: 250 2025-02-09 14:34:06.443 - debug: kecontact.0 (17578) power: 1386.3289999999997 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 2000 2025-02-09 14:34:06.443 - debug: kecontact.0 (17578) check with additional power of: 250 and underUsage: 500 2025-02-09 14:34:06.443 - debug: kecontact.0 (17578) power: 1886.3289999999997 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 3000 2025-02-09 14:34:06.443 - info: kecontact.0 (17578) minimum regard time of 180sec not reached, continuing charging session. RegardTimestamp: Sun Feb 09 2025 14:31:36 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:34:06.443 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:34:06.655 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:34:06.657 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 6548, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708478 } " 2025-02-09 14:34:06.657 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:34:13.255 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 6628}" 2025-02-09 14:34:21.054 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:34:21.056 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708493 } " 2025-02-09 14:34:21.354 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:34:21.355 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 231, "U2": 234, "U3": 232, "I1": 6060, "I2": 6119, "I3": 6084, "P": 4220413, "PF": 992, "E pres": 6721, "E total": 56276694, "Serial": "26663654", "Sec": 708493 } " 2025-02-09 14:34:21.430 - debug: kecontact.0 (17578) Available max power: 25055.213 2025-02-09 14:34:21.430 - debug: kecontact.0 (17578) power: 25055.213 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 36000 2025-02-09 14:34:21.430 - debug: kecontact.0 (17578) Available surplus: 1135.513 2025-02-09 14:34:21.654 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:34:21.655 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 6724, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708493 } " 2025-02-09 14:34:21.656 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:34:21.718 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 6727}" 2025-02-09 14:34:30.398 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 6828}" 2025-02-09 14:34:36.054 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:34:36.057 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708508 } " 2025-02-09 14:34:36.355 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:34:36.357 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 231, "U2": 234, "U3": 233, "I1": 6100, "I2": 6168, "I3": 6136, "P": 4257031, "PF": 991, "E pres": 6898, "E total": 56276871, "Serial": "26663654", "Sec": 708508 } " 2025-02-09 14:34:36.441 - debug: kecontact.0 (17578) Available max power: 25019.331 2025-02-09 14:34:36.441 - debug: kecontact.0 (17578) power: 25019.331 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 36000 2025-02-09 14:34:36.441 - debug: kecontact.0 (17578) Available surplus: 1096.2310000000002 2025-02-09 14:34:36.442 - debug: kecontact.0 (17578) power: 1096.2310000000002 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 2000 2025-02-09 14:34:36.442 - debug: kecontact.0 (17578) power: 1096.2310000000002 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 5000 2025-02-09 14:34:36.442 - debug: kecontact.0 (17578) check with additional power of: 250 2025-02-09 14:34:36.442 - debug: kecontact.0 (17578) power: 1346.2310000000002 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 6000 2025-02-09 14:34:36.442 - debug: kecontact.0 (17578) Minimum amperage reached by addPower of 250 2025-02-09 14:34:36.442 - info: kecontact.0 (17578) updating X2 for switch of phases from 1 to 0... 2025-02-09 14:34:36.442 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:34:36.655 - debug: kecontact.0 (17578) Sent "x2 0" to 10.1.4.9:7090 2025-02-09 14:34:36.656 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-OK :done " 2025-02-09 14:34:36.656 - debug: kecontact.0 (17578) Received TCH-OK :done 2025-02-09 14:34:36.746 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Enable sys": 0}" 2025-02-09 14:34:36.748 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"State": 5}" 2025-02-09 14:34:36.908 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Max curr": 0}" 2025-02-09 14:34:36.955 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:34:36.957 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 6905, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708508 } " 2025-02-09 14:34:36.957 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:34:37.565 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Enable sys": 1}" 2025-02-09 14:34:41.033 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Max curr": 6000}" 2025-02-09 14:34:44.492 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"State": 2}" 2025-02-09 14:34:45.400 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"State": 3}" 2025-02-09 14:34:51.055 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:34:51.058 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708523 } " 2025-02-09 14:34:51.355 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:34:51.357 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 234, "U2": 0, "U3": 0, "I1": 277, "I2": 0, "I3": 0, "P": 924, "PF": 14, "E pres": 6906, "E total": 56276879, "Serial": "26663654", "Sec": 708523 } " 2025-02-09 14:34:51.434 - debug: kecontact.0 (17578) Available max power: 22871.324 2025-02-09 14:34:51.434 - debug: kecontact.0 (17578) power: 22871.324 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:34:51.434 - debug: kecontact.0 (17578) Available surplus: 1103.7240000000002 2025-02-09 14:34:51.655 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:34:51.657 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 6906, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708523 } " 2025-02-09 14:34:51.657 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:35:01.430 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 6927}" 2025-02-09 14:35:06.056 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:35:06.059 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708538 } " 2025-02-09 14:35:06.356 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:35:06.357 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 232, "U2": 0, "U3": 0, "I1": 6132, "I2": 0, "I3": 0, "P": 1411463, "PF": 990, "E pres": 6945, "E total": 56276918, "Serial": "26663654", "Sec": 708538 } " 2025-02-09 14:35:06.451 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:35:06.451 - debug: kecontact.0 (17578) Available max power: 24360.063 2025-02-09 14:35:06.452 - debug: kecontact.0 (17578) power: 24360.063 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:35:06.452 - debug: kecontact.0 (17578) Available surplus: 1088.363 2025-02-09 14:35:06.452 - debug: kecontact.0 (17578) power: 1088.363 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 2000 2025-02-09 14:35:06.452 - debug: kecontact.0 (17578) power: 1088.363 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 5000 2025-02-09 14:35:06.452 - debug: kecontact.0 (17578) check with additional power of: 250 2025-02-09 14:35:06.452 - debug: kecontact.0 (17578) power: 1338.363 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 6000 2025-02-09 14:35:06.452 - debug: kecontact.0 (17578) Minimum amperage reached by addPower of 250 2025-02-09 14:35:06.452 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:35:06.656 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:35:06.659 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 6947, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708538 } " 2025-02-09 14:35:06.659 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:35:21.056 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:35:21.058 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708553 } " 2025-02-09 14:35:21.357 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:35:21.360 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 231, "U2": 0, "U3": 0, "I1": 6136, "I2": 0, "I3": 0, "P": 1406038, "PF": 990, "E pres": 7004, "E total": 56276977, "Serial": "26663654", "Sec": 708553 } " 2025-02-09 14:35:21.448 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:35:21.448 - debug: kecontact.0 (17578) Available max power: 23954.638 2025-02-09 14:35:21.448 - debug: kecontact.0 (17578) power: 23954.638 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:35:21.449 - debug: kecontact.0 (17578) Available surplus: 35.13799999999992 2025-02-09 14:35:21.657 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:35:21.659 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 7006, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708553 } " 2025-02-09 14:35:21.659 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:35:27.036 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 7027}" 2025-02-09 14:35:36.057 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:35:36.060 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708568 } " 2025-02-09 14:35:36.357 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:35:36.359 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 231, "U2": 0, "U3": 0, "I1": 6131, "I2": 0, "I3": 0, "P": 1409447, "PF": 991, "E pres": 7063, "E total": 56277036, "Serial": "26663654", "Sec": 708568 } " 2025-02-09 14:35:36.444 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:35:36.444 - debug: kecontact.0 (17578) Available max power: 24398.947 2025-02-09 14:35:36.444 - debug: kecontact.0 (17578) power: 24398.947 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:35:36.445 - debug: kecontact.0 (17578) Available surplus: 1065.947 2025-02-09 14:35:36.445 - debug: kecontact.0 (17578) power: 1065.947 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 2000 2025-02-09 14:35:36.445 - debug: kecontact.0 (17578) power: 1065.947 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 5000 2025-02-09 14:35:36.445 - debug: kecontact.0 (17578) check with additional power of: 250 2025-02-09 14:35:36.445 - debug: kecontact.0 (17578) power: 1315.947 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 6000 2025-02-09 14:35:36.445 - debug: kecontact.0 (17578) Minimum amperage reached by addPower of 250 2025-02-09 14:35:36.445 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:35:36.657 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:35:36.659 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 7064, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708568 } " 2025-02-09 14:35:36.659 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:35:51.058 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:35:51.061 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708583 } " 2025-02-09 14:35:51.358 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:35:51.360 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 232, "U2": 0, "U3": 0, "I1": 6141, "I2": 0, "I3": 0, "P": 1413980, "PF": 990, "E pres": 7122, "E total": 56277095, "Serial": "26663654", "Sec": 708583 } " 2025-02-09 14:35:51.438 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:35:51.438 - debug: kecontact.0 (17578) Available max power: 24417.18 2025-02-09 14:35:51.438 - debug: kecontact.0 (17578) power: 24417.18 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:35:51.438 - debug: kecontact.0 (17578) Available surplus: 1102.18 2025-02-09 14:35:51.659 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:35:51.662 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 7123, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708583 } " 2025-02-09 14:35:51.663 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:35:52.642 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 7127}" 2025-02-09 14:36:06.059 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:36:06.061 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708598 } " 2025-02-09 14:36:06.360 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:36:06.362 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 231, "U2": 0, "U3": 0, "I1": 6140, "I2": 0, "I3": 0, "P": 1411155, "PF": 991, "E pres": 7181, "E total": 56277154, "Serial": "26663654", "Sec": 708598 } " 2025-02-09 14:36:06.443 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:36:06.443 - debug: kecontact.0 (17578) Available max power: 24427.455 2025-02-09 14:36:06.443 - debug: kecontact.0 (17578) power: 24427.455 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:36:06.443 - debug: kecontact.0 (17578) Available surplus: 1167.655 2025-02-09 14:36:06.443 - debug: kecontact.0 (17578) power: 1167.655 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 2000 2025-02-09 14:36:06.443 - debug: kecontact.0 (17578) power: 1167.655 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 5000 2025-02-09 14:36:06.443 - debug: kecontact.0 (17578) check with additional power of: 250 2025-02-09 14:36:06.443 - debug: kecontact.0 (17578) power: 1417.655 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 6000 2025-02-09 14:36:06.443 - debug: kecontact.0 (17578) Minimum amperage reached by addPower of 250 2025-02-09 14:36:06.444 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:36:06.660 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:36:06.662 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 7182, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708598 } " 2025-02-09 14:36:06.663 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:36:18.031 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 7227}" 2025-02-09 14:36:21.060 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:36:21.062 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708613 } " 2025-02-09 14:36:21.360 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:36:21.363 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 232, "U2": 0, "U3": 0, "I1": 6143, "I2": 0, "I3": 0, "P": 1413216, "PF": 991, "E pres": 7240, "E total": 56277213, "Serial": "26663654", "Sec": 708613 } " 2025-02-09 14:36:21.439 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:36:21.439 - debug: kecontact.0 (17578) Available max power: 24699.316 2025-02-09 14:36:21.439 - debug: kecontact.0 (17578) power: 24699.316 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 36000 2025-02-09 14:36:21.439 - debug: kecontact.0 (17578) Available surplus: 1440.916 2025-02-09 14:36:21.660 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:36:21.663 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 7240, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708613 } " 2025-02-09 14:36:21.664 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:36:36.059 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:36:36.062 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708628 } " 2025-02-09 14:36:36.360 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:36:36.362 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 232, "U2": 0, "U3": 0, "I1": 6146, "I2": 0, "I3": 0, "P": 1414314, "PF": 991, "E pres": 7298, "E total": 56277271, "Serial": "26663654", "Sec": 708628 } " 2025-02-09 14:36:36.443 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:36:36.443 - debug: kecontact.0 (17578) Available max power: 24404.314 2025-02-09 14:36:36.443 - debug: kecontact.0 (17578) power: 24404.314 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:36:36.443 - debug: kecontact.0 (17578) Available surplus: 1379.0140000000001 2025-02-09 14:36:36.443 - debug: kecontact.0 (17578) power: 1379.0140000000001 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 2000 2025-02-09 14:36:36.443 - debug: kecontact.0 (17578) power: 1379.0140000000001 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 6000 2025-02-09 14:36:36.445 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:36:36.661 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:36:36.663 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 7299, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708628 } " 2025-02-09 14:36:36.663 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:36:43.636 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 7327}" 2025-02-09 14:36:51.060 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:36:51.062 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708643 } " 2025-02-09 14:36:51.360 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:36:51.361 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 232, "U2": 0, "U3": 0, "I1": 6138, "I2": 0, "I3": 0, "P": 1413146, "PF": 990, "E pres": 7357, "E total": 56277330, "Serial": "26663654", "Sec": 708643 } " 2025-02-09 14:36:51.441 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:36:51.442 - debug: kecontact.0 (17578) Available max power: 24429.546 2025-02-09 14:36:51.442 - debug: kecontact.0 (17578) power: 24429.546 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:36:51.442 - debug: kecontact.0 (17578) Available surplus: 1432.7459999999999 2025-02-09 14:36:51.660 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:36:51.663 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 7359, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708643 } " 2025-02-09 14:36:51.663 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:37:06.060 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:37:06.062 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708658 } " 2025-02-09 14:37:06.360 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:37:06.362 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 233, "U2": 0, "U3": 0, "I1": 6141, "I2": 0, "I3": 0, "P": 1420080, "PF": 991, "E pres": 7416, "E total": 56277389, "Serial": "26663654", "Sec": 708658 } " 2025-02-09 14:37:06.440 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:37:06.440 - debug: kecontact.0 (17578) Available max power: 24414.28 2025-02-09 14:37:06.440 - debug: kecontact.0 (17578) power: 24414.28 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:37:06.440 - debug: kecontact.0 (17578) Available surplus: 1433.6799999999998 2025-02-09 14:37:06.441 - debug: kecontact.0 (17578) power: 1433.6799999999998 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 2000 2025-02-09 14:37:06.441 - debug: kecontact.0 (17578) power: 1433.6799999999998 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 6000 2025-02-09 14:37:06.441 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:37:06.660 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:37:06.662 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 7418, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708658 } " 2025-02-09 14:37:06.662 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:37:09.025 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 7427}" 2025-02-09 14:37:21.060 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:37:21.062 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708673 } " 2025-02-09 14:37:21.360 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:37:21.363 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 233, "U2": 0, "U3": 0, "I1": 6135, "I2": 0, "I3": 0, "P": 1422006, "PF": 991, "E pres": 7475, "E total": 56277448, "Serial": "26663654", "Sec": 708673 } " 2025-02-09 14:37:21.449 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:37:21.450 - debug: kecontact.0 (17578) Available max power: 24424.106 2025-02-09 14:37:21.450 - debug: kecontact.0 (17578) power: 24424.106 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:37:21.450 - debug: kecontact.0 (17578) Available surplus: 1427.506 2025-02-09 14:37:21.662 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:37:21.664 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 7477, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708673 } " 2025-02-09 14:37:21.664 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:37:34.415 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 7527}" 2025-02-09 14:37:36.061 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:37:36.063 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708688 } " 2025-02-09 14:37:36.361 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:37:36.363 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 233, "U2": 0, "U3": 0, "I1": 6136, "I2": 0, "I3": 0, "P": 1419881, "PF": 991, "E pres": 7535, "E total": 56277508, "Serial": "26663654", "Sec": 708688 } " 2025-02-09 14:37:36.453 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:37:36.454 - debug: kecontact.0 (17578) Available max power: 24421.981 2025-02-09 14:37:36.454 - debug: kecontact.0 (17578) power: 24421.981 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:37:36.454 - debug: kecontact.0 (17578) Available surplus: 1347.681 2025-02-09 14:37:36.454 - debug: kecontact.0 (17578) power: 1347.681 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 2000 2025-02-09 14:37:36.454 - debug: kecontact.0 (17578) power: 1347.681 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 6000 2025-02-09 14:37:36.454 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:37:36.661 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:37:36.663 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 7536, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708688 } " 2025-02-09 14:37:36.663 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:37:51.062 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:37:51.064 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708703 } " 2025-02-09 14:37:51.361 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:37:51.363 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 232, "U2": 0, "U3": 0, "I1": 6141, "I2": 0, "I3": 0, "P": 1416491, "PF": 991, "E pres": 7594, "E total": 56277567, "Serial": "26663654", "Sec": 708703 } " 2025-02-09 14:37:51.457 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:37:51.458 - debug: kecontact.0 (17578) Available max power: 24404.491 2025-02-09 14:37:51.458 - debug: kecontact.0 (17578) power: 24404.491 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:37:51.458 - debug: kecontact.0 (17578) Available surplus: 1286.591 2025-02-09 14:37:51.662 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:37:51.664 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 7595, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708703 } " 2025-02-09 14:37:51.665 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:37:59.804 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 7627}" 2025-02-09 14:38:06.063 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:38:06.065 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708718 } " 2025-02-09 14:38:06.363 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:38:06.365 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 232, "U2": 0, "U3": 0, "I1": 6139, "I2": 0, "I3": 0, "P": 1412818, "PF": 991, "E pres": 7653, "E total": 56277626, "Serial": "26663654", "Sec": 708718 } " 2025-02-09 14:38:06.442 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:38:06.442 - debug: kecontact.0 (17578) Available max power: 24412.318 2025-02-09 14:38:06.442 - debug: kecontact.0 (17578) power: 24412.318 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:38:06.442 - debug: kecontact.0 (17578) Available surplus: 1325.818 2025-02-09 14:38:06.442 - debug: kecontact.0 (17578) power: 1325.818 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 2000 2025-02-09 14:38:06.442 - debug: kecontact.0 (17578) power: 1325.818 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 6000 2025-02-09 14:38:06.442 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:38:06.663 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:38:06.665 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 7654, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708718 } " 2025-02-09 14:38:06.666 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:38:21.063 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:38:21.065 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708733 } " 2025-02-09 14:38:21.363 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:38:21.366 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 231, "U2": 0, "U3": 0, "I1": 6133, "I2": 0, "I3": 0, "P": 1409550, "PF": 992, "E pres": 7712, "E total": 56277685, "Serial": "26663654", "Sec": 708733 } " 2025-02-09 14:38:21.448 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:38:21.448 - debug: kecontact.0 (17578) Available max power: 24407.25 2025-02-09 14:38:21.448 - debug: kecontact.0 (17578) power: 24407.25 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:38:21.448 - debug: kecontact.0 (17578) Available surplus: 1295.35 2025-02-09 14:38:21.663 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:38:21.665 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 7713, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708733 } " 2025-02-09 14:38:21.666 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:38:25.193 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 7727}" 2025-02-09 14:38:36.064 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:38:36.066 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708748 } " 2025-02-09 14:38:36.364 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:38:36.365 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 231, "U2": 0, "U3": 0, "I1": 6131, "I2": 0, "I3": 0, "P": 1406372, "PF": 991, "E pres": 7770, "E total": 56277743, "Serial": "26663654", "Sec": 708748 } " 2025-02-09 14:38:36.448 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:38:36.448 - debug: kecontact.0 (17578) Available max power: 24414.772 2025-02-09 14:38:36.448 - debug: kecontact.0 (17578) power: 24414.772 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:38:36.448 - debug: kecontact.0 (17578) Available surplus: 1347.972 2025-02-09 14:38:36.448 - debug: kecontact.0 (17578) power: 1347.972 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 2000 2025-02-09 14:38:36.448 - debug: kecontact.0 (17578) power: 1347.972 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 6000 2025-02-09 14:38:36.448 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:38:36.664 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:38:36.666 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 7771, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708748 } " 2025-02-09 14:38:36.666 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:38:50.799 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 7827}" 2025-02-09 14:38:51.064 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:38:51.066 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708763 } " 2025-02-09 14:38:51.365 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:38:51.366 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 230, "U2": 0, "U3": 0, "I1": 6126, "I2": 0, "I3": 0, "P": 1402365, "PF": 991, "E pres": 7829, "E total": 56277802, "Serial": "26663654", "Sec": 708763 } " 2025-02-09 14:38:51.476 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:38:51.476 - debug: kecontact.0 (17578) Available max power: 24426.865 2025-02-09 14:38:51.476 - debug: kecontact.0 (17578) power: 24426.865 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:38:51.476 - debug: kecontact.0 (17578) Available surplus: 1306.165 2025-02-09 14:38:51.665 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:38:51.666 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 7830, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708763 } " 2025-02-09 14:38:51.667 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:39:06.066 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:39:06.068 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708778 } " 2025-02-09 14:39:06.366 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:39:06.367 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 231, "U2": 0, "U3": 0, "I1": 6126, "I2": 0, "I3": 0, "P": 1404298, "PF": 991, "E pres": 7887, "E total": 56277860, "Serial": "26663654", "Sec": 708778 } " 2025-02-09 14:39:06.445 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:39:06.445 - debug: kecontact.0 (17578) Available max power: 24397.398 2025-02-09 14:39:06.445 - debug: kecontact.0 (17578) power: 24397.398 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:39:06.445 - debug: kecontact.0 (17578) Available surplus: 1260.298 2025-02-09 14:39:06.445 - debug: kecontact.0 (17578) power: 1260.298 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 2000 2025-02-09 14:39:06.445 - debug: kecontact.0 (17578) power: 1260.298 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 5000 2025-02-09 14:39:06.445 - debug: kecontact.0 (17578) check with additional power of: 250 2025-02-09 14:39:06.445 - debug: kecontact.0 (17578) power: 1510.298 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 7000 2025-02-09 14:39:06.445 - debug: kecontact.0 (17578) Minimum amperage reached by addPower of 250 2025-02-09 14:39:06.445 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:39:06.666 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:39:06.668 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 7889, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708778 } " 2025-02-09 14:39:06.668 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:39:16.405 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 7927}" 2025-02-09 14:39:21.067 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:39:21.069 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708793 } " 2025-02-09 14:39:21.367 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:39:21.368 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 232, "U2": 0, "U3": 0, "I1": 6132, "I2": 0, "I3": 0, "P": 1415752, "PF": 991, "E pres": 7946, "E total": 56277919, "Serial": "26663654", "Sec": 708793 } " 2025-02-09 14:39:21.453 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:39:21.453 - debug: kecontact.0 (17578) Available max power: 24424.452 2025-02-09 14:39:21.453 - debug: kecontact.0 (17578) power: 24424.452 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:39:21.453 - debug: kecontact.0 (17578) Available surplus: 1183.052 2025-02-09 14:39:21.667 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:39:21.670 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 7947, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708793 } " 2025-02-09 14:39:21.675 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:39:36.067 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:39:36.069 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708808 } " 2025-02-09 14:39:36.367 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:39:36.369 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 232, "U2": 0, "U3": 0, "I1": 6137, "I2": 0, "I3": 0, "P": 1412189, "PF": 992, "E pres": 8005, "E total": 56277978, "Serial": "26663654", "Sec": 708808 } " 2025-02-09 14:39:36.451 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:39:36.451 - debug: kecontact.0 (17578) Available max power: 24378.789 2025-02-09 14:39:36.451 - debug: kecontact.0 (17578) power: 24378.789 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:39:36.451 - debug: kecontact.0 (17578) Available surplus: 1068.3890000000001 2025-02-09 14:39:36.452 - debug: kecontact.0 (17578) power: 1068.3890000000001 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 2000 2025-02-09 14:39:36.452 - debug: kecontact.0 (17578) power: 1068.3890000000001 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 5000 2025-02-09 14:39:36.452 - debug: kecontact.0 (17578) check with additional power of: 250 2025-02-09 14:39:36.452 - debug: kecontact.0 (17578) power: 1318.3890000000001 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 6000 2025-02-09 14:39:36.452 - debug: kecontact.0 (17578) Minimum amperage reached by addPower of 250 2025-02-09 14:39:36.452 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:39:36.667 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:39:36.669 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 8006, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708808 } " 2025-02-09 14:39:36.669 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:39:41.795 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 8027}" 2025-02-09 14:39:51.067 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:39:51.069 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708823 } " 2025-02-09 14:39:51.368 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:39:51.370 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 232, "U2": 0, "U3": 0, "I1": 6133, "I2": 0, "I3": 0, "P": 1411926, "PF": 991, "E pres": 8064, "E total": 56278037, "Serial": "26663654", "Sec": 708823 } " 2025-02-09 14:39:51.444 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:39:51.444 - debug: kecontact.0 (17578) Available max power: 24411.326 2025-02-09 14:39:51.444 - debug: kecontact.0 (17578) power: 24411.326 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:39:51.444 - debug: kecontact.0 (17578) Available surplus: 1013.0259999999998 2025-02-09 14:39:51.668 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:39:51.670 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 8065, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708823 } " 2025-02-09 14:39:51.670 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:40:06.069 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:40:06.072 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708838 } " 2025-02-09 14:40:06.369 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:40:06.372 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 232, "U2": 0, "U3": 0, "I1": 6139, "I2": 0, "I3": 0, "P": 1416510, "PF": 991, "E pres": 8123, "E total": 56278096, "Serial": "26663654", "Sec": 708838 } " 2025-02-09 14:40:06.454 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:40:06.454 - debug: kecontact.0 (17578) Available max power: 24419.21 2025-02-09 14:40:06.454 - debug: kecontact.0 (17578) power: 24419.21 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:40:06.454 - debug: kecontact.0 (17578) Available surplus: 960.41 2025-02-09 14:40:06.454 - debug: kecontact.0 (17578) power: 960.41 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 1000 2025-02-09 14:40:06.454 - debug: kecontact.0 (17578) power: 960.41 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 4000 2025-02-09 14:40:06.454 - debug: kecontact.0 (17578) check with additional power of: 250 2025-02-09 14:40:06.455 - debug: kecontact.0 (17578) power: 1210.4099999999999 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 5000 2025-02-09 14:40:06.455 - debug: kecontact.0 (17578) check with additional power of: 250 and underUsage: 500 2025-02-09 14:40:06.455 - debug: kecontact.0 (17578) power: 1710.4099999999999 / voltage: 230 * 1000 / delta: 1000 / phases: 1 * delta = 7000 2025-02-09 14:40:06.455 - info: kecontact.0 (17578) tolerated under-usage of charge power, continuing charging session 2025-02-09 14:40:06.455 - debug: kecontact.0 (17578) wallbox set to charging maximum of 6000 mA 2025-02-09 14:40:06.669 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:40:06.670 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 8124, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708838 } " 2025-02-09 14:40:06.670 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:40:07.184 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 8127}" 2025-02-09 14:40:21.070 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:40:21.073 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708853 } " 2025-02-09 14:40:21.371 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:40:21.373 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 231, "U2": 0, "U3": 0, "I1": 6129, "I2": 0, "I3": 0, "P": 1404811, "PF": 991, "E pres": 8182, "E total": 56278155, "Serial": "26663654", "Sec": 708853 } " 2025-02-09 14:40:21.477 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:40:21.478 - debug: kecontact.0 (17578) Available max power: 24403.611 2025-02-09 14:40:21.478 - debug: kecontact.0 (17578) power: 24403.611 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:40:21.478 - debug: kecontact.0 (17578) Available surplus: 936.3109999999999 2025-02-09 14:40:21.671 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:40:21.673 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 8183, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708853 } " 2025-02-09 14:40:21.674 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:40:32.790 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 8227}" 2025-02-09 14:40:34.693 - info: kecontact.0 (17578) change pause status of wallbox from false to true 2025-02-09 14:40:34.693 - debug: kecontact.0 (17578) set automatic.pauseWallbox to true 2025-02-09 14:40:34.693 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:40:34.695 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 6000, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708866 } " 2025-02-09 14:40:34.993 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:40:34.995 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 230, "U2": 0, "U3": 0, "I1": 6132, "I2": 0, "I3": 0, "P": 1404645, "PF": 992, "E pres": 8235, "E total": 56278208, "Serial": "26663654", "Sec": 708866 } " 2025-02-09 14:40:35.079 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:40:35.079 - debug: kecontact.0 (17578) Available max power: 24392.845 2025-02-09 14:40:35.079 - debug: kecontact.0 (17578) power: 24392.845 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:40:35.080 - debug: kecontact.0 (17578) Available surplus: 894.345 2025-02-09 14:40:35.080 - debug: kecontact.0 (17578) not enough power for charging ... 2025-02-09 14:40:35.080 - info: kecontact.0 (17578) stop charging 2025-02-09 14:40:35.294 - debug: kecontact.0 (17578) Sent "currtime 0 1" to 10.1.4.9:7090 2025-02-09 14:40:35.296 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-OK :done " 2025-02-09 14:40:35.296 - debug: kecontact.0 (17578) Received TCH-OK :done 2025-02-09 14:40:35.595 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:40:35.598 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 8237, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708867 } " 2025-02-09 14:40:35.599 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:40:36.071 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:40:36.072 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 6000, "Max curr %": 100, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708868 } " 2025-02-09 14:40:36.304 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Enable sys": 0}" 2025-02-09 14:40:36.305 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"State": 5}" 2025-02-09 14:40:36.371 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:40:36.373 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 230, "U2": 0, "U3": 0, "I1": 6128, "I2": 0, "I3": 0, "P": 1404407, "PF": 992, "E pres": 8240, "E total": 56278213, "Serial": "26663654", "Sec": 708868 } " 2025-02-09 14:40:36.478 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Max curr": 0}" 2025-02-09 14:40:36.623 - debug: kecontact.0 (17578) wallbox is charging with 1 phase 2025-02-09 14:40:36.623 - debug: kecontact.0 (17578) Available max power: 24394.207 2025-02-09 14:40:36.623 - debug: kecontact.0 (17578) power: 24394.207 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 35000 2025-02-09 14:40:36.623 - debug: kecontact.0 (17578) Available surplus: 888.1069999999999 2025-02-09 14:40:36.671 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:40:36.673 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 8241, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708868 } " 2025-02-09 14:40:36.674 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:40:50.693 - info: kecontact.0 (17578) change of photovoltaics automatic from true to false 2025-02-09 14:40:50.694 - debug: kecontact.0 (17578) set automatic.photovoltaics to false 2025-02-09 14:40:50.694 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:40:50.696 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708882 } " 2025-02-09 14:40:50.994 - debug: kecontact.0 (17578) Sent "display 0 0 0 0 volle$Ladeleistung" to 10.1.4.9:7090 2025-02-09 14:40:51.022 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-OK :done " 2025-02-09 14:40:51.022 - debug: kecontact.0 (17578) Received TCH-OK :done 2025-02-09 14:40:51.294 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:40:51.295 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 8241, "E total": 56278214, "Serial": "26663654", "Sec": 708883 } " 2025-02-09 14:40:51.380 - debug: kecontact.0 (17578) Available max power: 23053.1 2025-02-09 14:40:51.380 - debug: kecontact.0 (17578) power: 23053.1 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:40:51.380 - debug: kecontact.0 (17578) Available surplus: -1153.6000000000001 2025-02-09 14:40:51.380 - debug: kecontact.0 (17578) not enough power for charging ... 2025-02-09 14:40:51.594 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:40:51.595 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 8241, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708883 } " 2025-02-09 14:40:51.596 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:40:51.894 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:40:51.897 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708883 } " 2025-02-09 14:40:52.194 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:40:52.195 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 8241, "E total": 56278214, "Serial": "26663654", "Sec": 708884 } " 2025-02-09 14:40:52.268 - debug: kecontact.0 (17578) Available max power: 22997.8 2025-02-09 14:40:52.268 - debug: kecontact.0 (17578) power: 22997.8 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:40:52.268 - debug: kecontact.0 (17578) Available surplus: -1112.8 2025-02-09 14:40:52.494 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:40:52.496 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 8241, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708884 } " 2025-02-09 14:40:52.497 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:41:05.372 - info: kecontact.0 (17578) change pause status of wallbox from true to false 2025-02-09 14:41:05.372 - debug: kecontact.0 (17578) set automatic.pauseWallbox to false 2025-02-09 14:41:05.372 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:41:05.374 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 708897 } " 2025-02-09 14:41:05.673 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:41:05.674 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 8241, "E total": 56278214, "Serial": "26663654", "Sec": 708897 } " 2025-02-09 14:41:05.758 - debug: kecontact.0 (17578) Available max power: 23001.8 2025-02-09 14:41:05.758 - debug: kecontact.0 (17578) power: 23001.8 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:41:05.758 - debug: kecontact.0 (17578) Available surplus: -1152.7 2025-02-09 14:41:05.758 - info: kecontact.0 (17578) updating X2 for switch of phases from 0 to 1... 2025-02-09 14:41:05.758 - debug: kecontact.0 (17578) wallbox set to charging maximum of 16000 mA 2025-02-09 14:41:05.758 - info: kecontact.0 (17578) (re)start charging with 16000mA (maxPower) 2025-02-09 14:41:05.973 - debug: kecontact.0 (17578) Sent "currtime 16000 1" to 10.1.4.9:7090 2025-02-09 14:41:05.974 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-OK :done " 2025-02-09 14:41:05.974 - debug: kecontact.0 (17578) Received TCH-OK :done 2025-02-09 14:41:06.273 - debug: kecontact.0 (17578) Sent "x2 1" to 10.1.4.9:7090 2025-02-09 14:41:06.275 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-OK :done " 2025-02-09 14:41:06.275 - debug: kecontact.0 (17578) Received TCH-OK :done 2025-02-09 14:41:06.354 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Enable sys": 1}" 2025-02-09 14:41:06.574 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:41:06.577 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 8241, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708898 } " 2025-02-09 14:41:06.578 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:41:06.874 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:41:06.876 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 6000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 16000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708898 } " 2025-02-09 14:41:07.174 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:41:07.176 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 8241, "E total": 56278214, "Serial": "26663654", "Sec": 708899 } " 2025-02-09 14:41:07.260 - debug: kecontact.0 (17578) Available max power: 22982 2025-02-09 14:41:07.261 - debug: kecontact.0 (17578) power: 22982 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:41:07.261 - debug: kecontact.0 (17578) Available surplus: -1232.7 2025-02-09 14:41:07.475 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:41:07.477 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 8241, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708899 } " 2025-02-09 14:41:07.477 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:41:08.811 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Max curr": 16000}" 2025-02-09 14:41:09.442 - debug: kecontact.0 (17578) set automatic.photovoltaics to false 2025-02-09 14:41:09.451 - info: kecontact.0 (17578) change pause status of wallbox from false to true 2025-02-09 14:41:09.452 - debug: kecontact.0 (17578) set automatic.pauseWallbox to true 2025-02-09 14:41:09.452 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:41:09.454 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 16000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 16000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708901 } " 2025-02-09 14:41:09.752 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:41:09.754 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 8241, "E total": 56278214, "Serial": "26663654", "Sec": 708901 } " 2025-02-09 14:41:09.840 - debug: kecontact.0 (17578) Available max power: 22992.9 2025-02-09 14:41:09.840 - debug: kecontact.0 (17578) power: 22992.9 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:41:09.840 - debug: kecontact.0 (17578) Available surplus: -1108.5 2025-02-09 14:41:09.840 - debug: kecontact.0 (17578) no switching to default phases because of minimum time between switching (stopCharging): Sun Feb 09 2025 14:41:05 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:41:09.840 - debug: kecontact.0 (17578) not enough power for charging ... 2025-02-09 14:41:09.840 - info: kecontact.0 (17578) stop charging 2025-02-09 14:41:10.052 - debug: kecontact.0 (17578) Sent "currtime 0 1" to 10.1.4.9:7090 2025-02-09 14:41:10.053 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-OK :done " 2025-02-09 14:41:10.053 - debug: kecontact.0 (17578) Received TCH-OK :done 2025-02-09 14:41:10.352 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:41:10.354 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 8241, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708902 } " 2025-02-09 14:41:10.354 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:41:11.421 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Enable sys": 0}" 2025-02-09 14:41:12.500 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Max curr": 0}" 2025-02-09 14:41:21.072 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:41:21.074 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 16000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708913 } " 2025-02-09 14:41:21.372 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:41:21.374 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 8241, "E total": 56278214, "Serial": "26663654", "Sec": 708913 } " 2025-02-09 14:41:21.447 - debug: kecontact.0 (17578) Available max power: 23003.2 2025-02-09 14:41:21.447 - debug: kecontact.0 (17578) power: 23003.2 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:41:21.447 - debug: kecontact.0 (17578) Available surplus: -1204.8999999999999 2025-02-09 14:41:21.671 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:41:21.674 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 8241, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708913 } " 2025-02-09 14:41:21.674 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:41:36.071 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:41:36.074 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 16000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708928 } " 2025-02-09 14:41:36.372 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:41:36.373 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 8241, "E total": 56278214, "Serial": "26663654", "Sec": 708928 } " 2025-02-09 14:41:36.488 - debug: kecontact.0 (17578) Available max power: 23574.1 2025-02-09 14:41:36.488 - debug: kecontact.0 (17578) power: 23574.1 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 34000 2025-02-09 14:41:36.488 - debug: kecontact.0 (17578) Available surplus: -1778.5 2025-02-09 14:41:36.488 - debug: kecontact.0 (17578) no switching to default phases because of minimum time between switching (stopCharging): Sun Feb 09 2025 14:41:05 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 14:41:36.488 - debug: kecontact.0 (17578) not enough power for charging ... 2025-02-09 14:41:36.672 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:41:36.674 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 8241, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708928 } " 2025-02-09 14:41:36.674 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:41:51.073 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:41:51.075 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 16000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708943 } " 2025-02-09 14:41:51.373 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:41:51.374 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 8241, "E total": 56278214, "Serial": "26663654", "Sec": 708943 } " 2025-02-09 14:41:51.454 - debug: kecontact.0 (17578) Available max power: 22977.3 2025-02-09 14:41:51.454 - debug: kecontact.0 (17578) power: 22977.3 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:41:51.454 - debug: kecontact.0 (17578) Available surplus: -1244.5 2025-02-09 14:41:51.673 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:41:51.676 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 8241, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708943 } " 2025-02-09 14:41:51.676 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:42:00.293 - info: kecontact.0 (17578) change pause status of wallbox from true to false 2025-02-09 14:42:00.293 - debug: kecontact.0 (17578) set automatic.pauseWallbox to false 2025-02-09 14:42:00.293 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:42:00.295 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 16000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708952 } " 2025-02-09 14:42:00.593 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:42:00.595 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 8241, "E total": 56278214, "Serial": "26663654", "Sec": 708952 } " 2025-02-09 14:42:00.671 - debug: kecontact.0 (17578) Available max power: 23032.4 2025-02-09 14:42:00.671 - debug: kecontact.0 (17578) power: 23032.4 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:42:00.671 - debug: kecontact.0 (17578) Available surplus: -1229.6999999999998 2025-02-09 14:42:00.671 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:42:00.671 - info: kecontact.0 (17578) (re)start charging with 32000mA (maxPower) 2025-02-09 14:42:00.893 - debug: kecontact.0 (17578) Sent "currtime 32000 1" to 10.1.4.9:7090 2025-02-09 14:42:00.895 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-OK :done " 2025-02-09 14:42:00.895 - debug: kecontact.0 (17578) Received TCH-OK :done 2025-02-09 14:42:01.194 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:42:01.197 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 8241, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708953 } " 2025-02-09 14:42:01.197 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:42:01.906 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Enable sys": 1}" 2025-02-09 14:42:04.377 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Max curr": 16000}" 2025-02-09 14:42:06.073 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:42:06.075 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 32000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708958 } " 2025-02-09 14:42:06.373 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:42:06.376 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 8241, "E total": 56278214, "Serial": "26663654", "Sec": 708958 } " 2025-02-09 14:42:06.468 - debug: kecontact.0 (17578) Available max power: 22999 2025-02-09 14:42:06.468 - debug: kecontact.0 (17578) power: 22999 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:42:06.468 - debug: kecontact.0 (17578) Available surplus: -1227.2 2025-02-09 14:42:06.673 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:42:06.680 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 8241, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708958 } " 2025-02-09 14:42:06.680 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:42:07.832 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"State": 2}" 2025-02-09 14:42:08.739 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"State": 3}" 2025-02-09 14:42:21.073 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:42:21.076 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 32000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708973 } " 2025-02-09 14:42:21.374 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:42:21.376 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 228, "U2": 238, "U3": 236, "I1": 4038, "I2": 400, "I3": 278, "P": 962337, "PF": 846, "E pres": 8247, "E total": 56278220, "Serial": "26663654", "Sec": 708973 } " 2025-02-09 14:42:21.464 - debug: kecontact.0 (17578) Available max power: 23056.037 2025-02-09 14:42:21.464 - debug: kecontact.0 (17578) power: 23056.037 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:42:21.464 - debug: kecontact.0 (17578) Available surplus: -866.8629999999998 2025-02-09 14:42:21.674 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:42:21.676 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 8248, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708973 } " 2025-02-09 14:42:21.676 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:42:30.840 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 8327}" 2025-02-09 14:42:35.395 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 8429}" 2025-02-09 14:42:36.074 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:42:36.077 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 32000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 708988 } " 2025-02-09 14:42:36.373 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:42:36.375 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 225, "U2": 233, "U3": 231, "I1": 15370, "I2": 15546, "I3": 15760, "P": 10857140, "PF": 996, "E pres": 8455, "E total": 56278428, "Serial": "26663654", "Sec": 708988 } " 2025-02-09 14:42:36.456 - debug: kecontact.0 (17578) Available max power: 24709.14 2025-02-09 14:42:36.456 - debug: kecontact.0 (17578) power: 24709.14 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 36000 2025-02-09 14:42:36.456 - debug: kecontact.0 (17578) Available surplus: 788.4399999999987 2025-02-09 14:42:36.456 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:42:36.674 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:42:36.675 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 8461, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 708988 } " 2025-02-09 14:42:36.675 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:42:38.650 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 8528}" 2025-02-09 14:42:39.449 - debug: kecontact.0 (17578) set automatic.pauseWallbox to false 2025-02-09 14:42:41.905 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 8628}" 2025-02-09 14:42:45.160 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 8728}" 2025-02-09 14:42:48.632 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 8833}" 2025-02-09 14:42:51.074 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:42:51.077 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 32000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709003 } " 2025-02-09 14:42:51.375 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:42:51.377 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 226, "U2": 233, "U3": 231, "I1": 15776, "I2": 15917, "I3": 15905, "P": 10946100, "PF": 998, "E pres": 8912, "E total": 56278885, "Serial": "26663654", "Sec": 709003 } " 2025-02-09 14:42:51.479 - info: kecontact.0 (17578) vehicle (re)starts to charge 2025-02-09 14:42:51.479 - debug: kecontact.0 (17578) Available max power: 22605.1 2025-02-09 14:42:51.479 - debug: kecontact.0 (17578) power: 22605.1 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:42:51.479 - debug: kecontact.0 (17578) Available surplus: -1315.699999999999 2025-02-09 14:42:51.676 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:42:51.678 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 8926, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709003 } " 2025-02-09 14:42:51.678 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:42:51.890 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 8932}" 2025-02-09 14:42:55.142 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 9032}" 2025-02-09 14:42:58.397 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 9130}" 2025-02-09 14:43:01.652 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 9230}" 2025-02-09 14:43:04.907 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 9328}" 2025-02-09 14:43:06.075 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:43:06.077 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 32000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709018 } " 2025-02-09 14:43:06.375 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:43:06.377 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 225, "U2": 233, "U3": 231, "I1": 15828, "I2": 15999, "I3": 15983, "P": 10983828, "PF": 998, "E pres": 9368, "E total": 56279341, "Serial": "26663654", "Sec": 709018 } " 2025-02-09 14:43:06.462 - debug: kecontact.0 (17578) Available max power: 22678.828 2025-02-09 14:43:06.462 - debug: kecontact.0 (17578) power: 22678.828 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:43:06.462 - debug: kecontact.0 (17578) Available surplus: -1242.1720000000005 2025-02-09 14:43:06.462 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:43:06.676 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:43:06.678 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 9381, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709018 } " 2025-02-09 14:43:06.678 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:43:08.165 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 9427}" 2025-02-09 14:43:11.417 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 9528}" 2025-02-09 14:43:14.672 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 9627}" 2025-02-09 14:43:17.927 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 9728}" 2025-02-09 14:43:21.076 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:43:21.079 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 32000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709033 } " 2025-02-09 14:43:21.182 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 9827}" 2025-02-09 14:43:21.376 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:43:21.378 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 227, "U2": 233, "U3": 231, "I1": 15903, "I2": 16050, "I3": 16032, "P": 11056653, "PF": 998, "E pres": 9827, "E total": 56279800, "Serial": "26663654", "Sec": 709033 } " 2025-02-09 14:43:21.457 - debug: kecontact.0 (17578) Available max power: 22627.653 2025-02-09 14:43:21.457 - debug: kecontact.0 (17578) power: 22627.653 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:43:21.457 - debug: kecontact.0 (17578) Available surplus: -1294.7469999999994 2025-02-09 14:43:21.676 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:43:21.678 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 9841, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709033 } " 2025-02-09 14:43:21.678 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:43:24.440 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 9927}" 2025-02-09 14:43:27.702 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 10027}" 2025-02-09 14:43:30.957 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 10128}" 2025-02-09 14:43:34.212 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 10228}" 2025-02-09 14:43:36.077 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:43:36.080 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 32000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709048 } " 2025-02-09 14:43:36.377 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:43:36.380 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 223, "U2": 233, "U3": 231, "I1": 15757, "I2": 16060, "I3": 16004, "P": 10987803, "PF": 999, "E pres": 10295, "E total": 56280268, "Serial": "26663654", "Sec": 709048 } " 2025-02-09 14:43:36.475 - debug: kecontact.0 (17578) Available max power: 21472.803 2025-02-09 14:43:36.475 - debug: kecontact.0 (17578) power: 21472.803 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 31000 2025-02-09 14:43:36.475 - debug: kecontact.0 (17578) Available surplus: -2451.4969999999994 2025-02-09 14:43:36.475 - debug: kecontact.0 (17578) wallbox set to charging maximum of 31000 mA 2025-02-09 14:43:36.475 - info: kecontact.0 (17578) regulate wallbox from 32000 to 31000mA (maxPower) 2025-02-09 14:43:36.678 - debug: kecontact.0 (17578) Sent "currtime 31000 1" to 10.1.4.9:7090 2025-02-09 14:43:36.679 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-OK :done " 2025-02-09 14:43:36.680 - debug: kecontact.0 (17578) Received TCH-OK :done 2025-02-09 14:43:36.978 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:43:36.980 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 10307, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709048 } " 2025-02-09 14:43:36.980 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:43:37.467 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 10327}" 2025-02-09 14:43:40.725 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 10427}" 2025-02-09 14:43:44.194 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 10532}" 2025-02-09 14:43:47.449 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 10631}" 2025-02-09 14:43:50.705 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 10729}" 2025-02-09 14:43:51.077 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:43:51.079 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 31000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 31000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709063 } " 2025-02-09 14:43:51.378 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:43:51.380 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 223, "U2": 234, "U3": 232, "I1": 15736, "I2": 15908, "I3": 15868, "P": 10915023, "PF": 998, "E pres": 10749, "E total": 56280722, "Serial": "26663654", "Sec": 709063 } " 2025-02-09 14:43:51.467 - debug: kecontact.0 (17578) Available max power: 20646.023 2025-02-09 14:43:51.467 - debug: kecontact.0 (17578) power: 20646.023 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 30000 2025-02-09 14:43:51.467 - debug: kecontact.0 (17578) Available surplus: -3277.4770000000008 2025-02-09 14:43:51.678 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:43:51.681 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 10755, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709063 } " 2025-02-09 14:43:51.681 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:43:53.960 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 10829}" 2025-02-09 14:43:57.215 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 10928}" 2025-02-09 14:44:00.470 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 11029}" 2025-02-09 14:44:03.725 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 11127}" 2025-02-09 14:44:06.078 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:44:06.080 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 31000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 31000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709078 } " 2025-02-09 14:44:06.378 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:44:06.380 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 224, "U2": 234, "U3": 232, "I1": 15638, "I2": 15844, "I3": 15819, "P": 10898554, "PF": 998, "E pres": 11207, "E total": 56281180, "Serial": "26663654", "Sec": 709078 } " 2025-02-09 14:44:06.467 - debug: kecontact.0 (17578) Available max power: 22490.554 2025-02-09 14:44:06.467 - debug: kecontact.0 (17578) power: 22490.554 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:44:06.467 - debug: kecontact.0 (17578) Available surplus: -1433.7459999999992 2025-02-09 14:44:06.468 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:44:06.468 - info: kecontact.0 (17578) regulate wallbox from 31000 to 32000mA (maxPower) 2025-02-09 14:44:06.679 - debug: kecontact.0 (17578) Sent "currtime 32000 1" to 10.1.4.9:7090 2025-02-09 14:44:06.680 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-OK :done " 2025-02-09 14:44:06.680 - debug: kecontact.0 (17578) Received TCH-OK :done 2025-02-09 14:44:06.979 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 11228}" 2025-02-09 14:44:06.980 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:44:06.982 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 11228, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709078 } " 2025-02-09 14:44:06.983 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:44:10.452 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 11333}" 2025-02-09 14:44:13.707 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 11431}" 2025-02-09 14:44:16.961 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 11530}" 2025-02-09 14:44:20.217 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 11630}" 2025-02-09 14:44:21.079 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:44:21.082 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 32000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709093 } " 2025-02-09 14:44:21.379 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:44:21.381 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 224, "U2": 234, "U3": 232, "I1": 15820, "I2": 16030, "I3": 15956, "P": 11005653, "PF": 999, "E pres": 11663, "E total": 56281636, "Serial": "26663654", "Sec": 709093 } " 2025-02-09 14:44:21.466 - debug: kecontact.0 (17578) Available max power: 20691.653 2025-02-09 14:44:21.466 - debug: kecontact.0 (17578) power: 20691.653 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 30000 2025-02-09 14:44:21.466 - debug: kecontact.0 (17578) Available surplus: -3231.646999999999 2025-02-09 14:44:21.679 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:44:21.682 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 11670, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709093 } " 2025-02-09 14:44:21.682 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:44:23.471 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 11730}" 2025-02-09 14:44:26.727 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 11828}" 2025-02-09 14:44:29.982 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 11927}" 2025-02-09 14:44:33.453 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 12033}" 2025-02-09 14:44:36.080 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:44:36.081 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 32000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709108 } " 2025-02-09 14:44:36.380 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:44:36.382 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 224, "U2": 234, "U3": 231, "I1": 15715, "I2": 15900, "I3": 15851, "P": 10920988, "PF": 998, "E pres": 12119, "E total": 56282092, "Serial": "26663654", "Sec": 709108 } " 2025-02-09 14:44:36.459 - debug: kecontact.0 (17578) Available max power: 20733.987999999998 2025-02-09 14:44:36.459 - debug: kecontact.0 (17578) power: 20733.987999999998 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 30000 2025-02-09 14:44:36.459 - debug: kecontact.0 (17578) Available surplus: -3188.112000000001 2025-02-09 14:44:36.460 - debug: kecontact.0 (17578) wallbox set to charging maximum of 30000 mA 2025-02-09 14:44:36.460 - info: kecontact.0 (17578) regulate wallbox from 32000 to 30000mA (maxPower) 2025-02-09 14:44:36.681 - debug: kecontact.0 (17578) Sent "currtime 30000 1" to 10.1.4.9:7090 2025-02-09 14:44:36.684 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-OK :done " 2025-02-09 14:44:36.684 - debug: kecontact.0 (17578) Received TCH-OK :done 2025-02-09 14:44:36.709 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 12131}" 2025-02-09 14:44:36.981 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:44:36.983 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 12137, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709108 } " 2025-02-09 14:44:36.983 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:44:39.964 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 12230}" 2025-02-09 14:44:43.219 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 12328}" 2025-02-09 14:44:46.691 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 12433}" 2025-02-09 14:44:49.946 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 12532}" 2025-02-09 14:44:51.080 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:44:51.081 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 30000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 30000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709123 } " 2025-02-09 14:44:51.380 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:44:51.382 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 224, "U2": 235, "U3": 231, "I1": 15651, "I2": 15819, "I3": 15802, "P": 10871780, "PF": 998, "E pres": 12571, "E total": 56282544, "Serial": "26663654", "Sec": 709123 } " 2025-02-09 14:44:51.462 - debug: kecontact.0 (17578) Available max power: 20731.78 2025-02-09 14:44:51.462 - debug: kecontact.0 (17578) power: 20731.78 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 30000 2025-02-09 14:44:51.462 - debug: kecontact.0 (17578) Available surplus: -3189.8199999999997 2025-02-09 14:44:51.680 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:44:51.681 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 12584, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709123 } " 2025-02-09 14:44:51.682 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:44:53.200 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 12631}" 2025-02-09 14:44:56.455 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 12728}" 2025-02-09 14:44:59.710 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 12827}" 2025-02-09 14:45:03.182 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 12932}" 2025-02-09 14:45:06.080 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:45:06.082 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 30000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 30000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709138 } " 2025-02-09 14:45:06.381 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:45:06.383 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 223, "U2": 235, "U3": 231, "I1": 15623, "I2": 15774, "I3": 15785, "P": 10861596, "PF": 998, "E pres": 13023, "E total": 56282996, "Serial": "26663654", "Sec": 709138 } " 2025-02-09 14:45:06.437 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 13029}" 2025-02-09 14:45:06.556 - debug: kecontact.0 (17578) Available max power: 20759.595999999998 2025-02-09 14:45:06.557 - debug: kecontact.0 (17578) power: 20759.595999999998 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 30000 2025-02-09 14:45:06.557 - debug: kecontact.0 (17578) Available surplus: -3160.9040000000005 2025-02-09 14:45:06.557 - debug: kecontact.0 (17578) wallbox set to charging maximum of 30000 mA 2025-02-09 14:45:06.681 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:45:06.684 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 13036, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709138 } " 2025-02-09 14:45:06.684 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:45:09.692 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 13128}" 2025-02-09 14:45:13.164 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 13233}" 2025-02-09 14:45:16.419 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 13331}" 2025-02-09 14:45:19.674 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 13431}" 2025-02-09 14:45:21.082 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:45:21.084 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 30000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 30000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709153 } " 2025-02-09 14:45:21.382 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:45:21.385 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 223, "U2": 235, "U3": 231, "I1": 15797, "I2": 15983, "I3": 15913, "P": 10965805, "PF": 998, "E pres": 13477, "E total": 56283450, "Serial": "26663654", "Sec": 709153 } " 2025-02-09 14:45:21.468 - debug: kecontact.0 (17578) Available max power: 20749.805 2025-02-09 14:45:21.468 - debug: kecontact.0 (17578) power: 20749.805 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 30000 2025-02-09 14:45:21.468 - debug: kecontact.0 (17578) Available surplus: -3168.295 2025-02-09 14:45:21.681 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:45:21.684 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 13490, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709153 } " 2025-02-09 14:45:21.684 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:45:22.929 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 13530}" 2025-02-09 14:45:26.185 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 13629}" 2025-02-09 14:45:29.439 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 13727}" 2025-02-09 14:45:32.911 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 13832}" 2025-02-09 14:45:36.083 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:45:36.085 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 30000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 30000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709168 } " 2025-02-09 14:45:36.166 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 13930}" 2025-02-09 14:45:36.383 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:45:36.384 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 224, "U2": 235, "U3": 230, "I1": 15669, "I2": 15853, "I3": 15809, "P": 10887876, "PF": 998, "E pres": 13937, "E total": 56283910, "Serial": "26663654", "Sec": 709168 } " 2025-02-09 14:45:36.469 - debug: kecontact.0 (17578) Available max power: 20721.876 2025-02-09 14:45:36.469 - debug: kecontact.0 (17578) power: 20721.876 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 30000 2025-02-09 14:45:36.469 - debug: kecontact.0 (17578) Available surplus: -3198.724 2025-02-09 14:45:36.470 - debug: kecontact.0 (17578) wallbox set to charging maximum of 30000 mA 2025-02-09 14:45:36.683 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:45:36.685 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 13944, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709168 } " 2025-02-09 14:45:36.685 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:45:39.421 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 14029}" 2025-02-09 14:45:42.677 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 14129}" 2025-02-09 14:45:45.931 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 14228}" 2025-02-09 14:45:49.187 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 14327}" 2025-02-09 14:45:51.083 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:45:51.085 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 30000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 30000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709183 } " 2025-02-09 14:45:51.383 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:45:51.384 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 224, "U2": 235, "U3": 231, "I1": 15667, "I2": 15853, "I3": 15813, "P": 10898875, "PF": 998, "E pres": 14392, "E total": 56284365, "Serial": "26663654", "Sec": 709183 } " 2025-02-09 14:45:51.470 - debug: kecontact.0 (17578) Available max power: 20664.875 2025-02-09 14:45:51.470 - debug: kecontact.0 (17578) power: 20664.875 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 30000 2025-02-09 14:45:51.470 - debug: kecontact.0 (17578) Available surplus: -3258.2250000000004 2025-02-09 14:45:51.683 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:45:51.685 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 14398, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709183 } " 2025-02-09 14:45:51.685 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:45:52.658 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 14432}" 2025-02-09 14:45:55.913 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 14530}" 2025-02-09 14:45:59.169 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 14629}" 2025-02-09 14:46:02.424 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 14728}" 2025-02-09 14:46:05.679 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 14827}" 2025-02-09 14:46:06.084 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:46:06.086 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 30000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 30000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709198 } " 2025-02-09 14:46:06.384 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:46:06.386 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 224, "U2": 235, "U3": 231, "I1": 15745, "I2": 15931, "I3": 15901, "P": 10984464, "PF": 998, "E pres": 14847, "E total": 56284820, "Serial": "26663654", "Sec": 709198 } " 2025-02-09 14:46:06.463 - debug: kecontact.0 (17578) Available max power: 20646.464 2025-02-09 14:46:06.463 - debug: kecontact.0 (17578) power: 20646.464 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 30000 2025-02-09 14:46:06.463 - debug: kecontact.0 (17578) Available surplus: -3276.036 2025-02-09 14:46:06.463 - debug: kecontact.0 (17578) wallbox set to charging maximum of 30000 mA 2025-02-09 14:46:06.684 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:46:06.686 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 14854, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709198 } " 2025-02-09 14:46:06.686 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:46:09.150 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 14933}" 2025-02-09 14:46:12.406 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 15032}" 2025-02-09 14:46:15.661 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 15131}" 2025-02-09 14:46:18.916 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 15230}" 2025-02-09 14:46:21.085 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:46:21.088 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 30000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 30000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709213 } " 2025-02-09 14:46:21.385 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:46:21.388 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 226, "U2": 234, "U3": 231, "I1": 15670, "I2": 15818, "I3": 15806, "P": 10927037, "PF": 999, "E pres": 15303, "E total": 56285276, "Serial": "26663654", "Sec": 709213 } " 2025-02-09 14:46:21.468 - debug: kecontact.0 (17578) Available max power: 20590.037 2025-02-09 14:46:21.469 - debug: kecontact.0 (17578) power: 20590.037 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 30000 2025-02-09 14:46:21.469 - debug: kecontact.0 (17578) Available surplus: -3331.262999999999 2025-02-09 14:46:21.685 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:46:21.687 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 15309, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709213 } " 2025-02-09 14:46:21.687 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:46:22.171 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 15329}" 2025-02-09 14:46:25.427 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 15428}" 2025-02-09 14:46:28.681 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 15527}" 2025-02-09 14:46:32.153 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 15633}" 2025-02-09 14:46:35.408 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 15732}" 2025-02-09 14:46:36.085 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:46:36.088 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 30000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 30000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709228 } " 2025-02-09 14:46:36.386 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:46:36.388 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 225, "U2": 235, "U3": 232, "I1": 15794, "I2": 16016, "I3": 15928, "P": 11015290, "PF": 999, "E pres": 15759, "E total": 56285732, "Serial": "26663654", "Sec": 709228 } " 2025-02-09 14:46:36.473 - debug: kecontact.0 (17578) Available max power: 20598.29 2025-02-09 14:46:36.473 - debug: kecontact.0 (17578) power: 20598.29 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 30000 2025-02-09 14:46:36.473 - debug: kecontact.0 (17578) Available surplus: -3322.3099999999995 2025-02-09 14:46:36.473 - debug: kecontact.0 (17578) wallbox set to charging maximum of 30000 mA 2025-02-09 14:46:36.687 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:46:36.689 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 15766, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709228 } " 2025-02-09 14:46:36.689 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:46:38.663 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 15832}" 2025-02-09 14:46:41.918 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 15931}" 2025-02-09 14:46:45.173 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 16031}" 2025-02-09 14:46:48.428 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 16131}" 2025-02-09 14:46:51.086 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:46:51.089 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 30000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 30000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709243 } " 2025-02-09 14:46:51.386 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:46:51.388 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 226, "U2": 235, "U3": 231, "I1": 15804, "I2": 15991, "I3": 15930, "P": 11010436, "PF": 998, "E pres": 16218, "E total": 56286191, "Serial": "26663654", "Sec": 709243 } " 2025-02-09 14:46:51.516 - debug: kecontact.0 (17578) Available max power: 20512.436 2025-02-09 14:46:51.516 - debug: kecontact.0 (17578) power: 20512.436 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 30000 2025-02-09 14:46:51.517 - debug: kecontact.0 (17578) Available surplus: -3413.8639999999996 2025-02-09 14:46:51.683 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 16230}" 2025-02-09 14:46:51.685 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:46:51.690 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 16230, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709243 } " 2025-02-09 14:46:51.691 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:46:54.938 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 16331}" 2025-02-09 14:46:58.193 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 16430}" 2025-02-09 14:47:01.448 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 16529}" 2025-02-09 14:47:04.703 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 16627}" 2025-02-09 14:47:06.086 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:47:06.091 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 30000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 30000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709258 } " 2025-02-09 14:47:06.387 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:47:06.389 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 226, "U2": 234, "U3": 230, "I1": 15743, "I2": 15932, "I3": 15898, "P": 10976200, "PF": 998, "E pres": 16674, "E total": 56286647, "Serial": "26663654", "Sec": 709258 } " 2025-02-09 14:47:06.512 - debug: kecontact.0 (17578) Available max power: 20451.2 2025-02-09 14:47:06.512 - debug: kecontact.0 (17578) power: 20451.2 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 30000 2025-02-09 14:47:06.512 - debug: kecontact.0 (17578) Available surplus: -3469.5999999999985 2025-02-09 14:47:06.512 - debug: kecontact.0 (17578) wallbox set to charging maximum of 30000 mA 2025-02-09 14:47:06.687 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:47:06.690 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 16688, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709258 } " 2025-02-09 14:47:06.690 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:47:07.958 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 16727}" 2025-02-09 14:47:11.430 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 16833}" 2025-02-09 14:47:14.685 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 16933}" 2025-02-09 14:47:17.940 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 17032}" 2025-02-09 14:47:21.086 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:47:21.088 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 30000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 30000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709273 } " 2025-02-09 14:47:21.195 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 17131}" 2025-02-09 14:47:21.386 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:47:21.389 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 226, "U2": 235, "U3": 230, "I1": 15823, "I2": 15978, "I3": 15961, "P": 11003502, "PF": 998, "E pres": 17131, "E total": 56287104, "Serial": "26663654", "Sec": 709273 } " 2025-02-09 14:47:21.474 - debug: kecontact.0 (17578) Available max power: 20538.502 2025-02-09 14:47:21.474 - debug: kecontact.0 (17578) power: 20538.502 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 30000 2025-02-09 14:47:21.474 - debug: kecontact.0 (17578) Available surplus: -3384.4979999999996 2025-02-09 14:47:21.687 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:47:21.689 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17146, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709273 } " 2025-02-09 14:47:21.689 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:47:24.450 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 17232}" 2025-02-09 14:47:27.705 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 17331}" 2025-02-09 14:47:30.960 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 17431}" 2025-02-09 14:47:34.215 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 17531}" 2025-02-09 14:47:36.086 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:47:36.089 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 3, "Error1": 0, "Error2": 0, "Plug": 7, "AuthON": 1, "Authreq": 0, "Enable sys": 1, "Enable user": 1, "Max curr": 16000, "Max curr %": 266, "Curr HW": 32000, "Curr user": 30000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 30000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709288 } " 2025-02-09 14:47:36.387 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:47:36.389 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 226, "U2": 234, "U3": 230, "I1": 15843, "I2": 15993, "I3": 15964, "P": 10997954, "PF": 998, "E pres": 17598, "E total": 56287571, "Serial": "26663654", "Sec": 709288 } " 2025-02-09 14:47:36.471 - debug: kecontact.0 (17578) Available max power: 20520.953999999998 2025-02-09 14:47:36.471 - debug: kecontact.0 (17578) power: 20520.953999999998 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 30000 2025-02-09 14:47:36.471 - debug: kecontact.0 (17578) Available surplus: -3401.1460000000006 2025-02-09 14:47:36.472 - debug: kecontact.0 (17578) wallbox set to charging maximum of 30000 mA 2025-02-09 14:47:36.688 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:47:36.690 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17604, "started[s]": 1739107387, "ended[s]": 0, "started": "2025-02-09 13:23:07.000", "ended": "0", "reason": 5, "timeQ": 0, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709288 } " 2025-02-09 14:47:36.690 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:47:37.470 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 17630}" 2025-02-09 14:47:40.725 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 17730}" 2025-02-09 14:47:43.980 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 17829}" 2025-02-09 14:47:47.235 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"E pres": 17929}" 2025-02-09 14:47:47.752 - debug: kecontact.0 (17578) Sent "stop 04420f8a5d6f80" to 10.1.4.9:7090 2025-02-09 14:47:47.754 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-OK :done " 2025-02-09 14:47:47.754 - debug: kecontact.0 (17578) Received TCH-OK :done 2025-02-09 14:47:48.140 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Enable sys": 0}" 2025-02-09 14:47:48.151 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"State": 5}" 2025-02-09 14:47:48.319 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Max curr": 0}" 2025-02-09 14:47:49.022 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Plug": 5}" 2025-02-09 14:47:51.086 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:47:51.089 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 1, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 30000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 30000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709303 } " 2025-02-09 14:47:51.386 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:47:51.389 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709303 } " 2025-02-09 14:47:51.474 - debug: kecontact.0 (17578) Available max power: 19387 2025-02-09 14:47:51.474 - debug: kecontact.0 (17578) power: 19387 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 28000 2025-02-09 14:47:51.474 - debug: kecontact.0 (17578) Available surplus: -10485 2025-02-09 14:47:51.686 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:47:51.689 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709303 } " 2025-02-09 14:47:51.689 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:48:06.086 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:48:06.088 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 1, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 30000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 30000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709318 } " 2025-02-09 14:48:06.387 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:48:06.389 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709318 } " 2025-02-09 14:48:06.466 - debug: kecontact.0 (17578) Available max power: 22910.1 2025-02-09 14:48:06.466 - debug: kecontact.0 (17578) power: 22910.1 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:48:06.466 - debug: kecontact.0 (17578) Available surplus: -3431.5 2025-02-09 14:48:06.466 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:48:06.466 - info: kecontact.0 (17578) regulate wallbox from 30000 to 32000mA (maxPower) 2025-02-09 14:48:06.688 - debug: kecontact.0 (17578) Sent "currtime 32000 1" to 10.1.4.9:7090 2025-02-09 14:48:06.689 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-OK :done " 2025-02-09 14:48:06.690 - debug: kecontact.0 (17578) Received TCH-OK :done 2025-02-09 14:48:06.988 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:48:06.990 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709318 } " 2025-02-09 14:48:06.990 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:48:21.087 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:48:21.089 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 1, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 32000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709333 } " 2025-02-09 14:48:21.389 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:48:21.391 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709333 } " 2025-02-09 14:48:21.489 - debug: kecontact.0 (17578) Available max power: 22997.8 2025-02-09 14:48:21.489 - debug: kecontact.0 (17578) power: 22997.8 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:48:21.489 - debug: kecontact.0 (17578) Available surplus: -3411.7999999999997 2025-02-09 14:48:21.689 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:48:21.692 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709333 } " 2025-02-09 14:48:21.692 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:48:36.089 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:48:36.091 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 1, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 32000, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709348 } " 2025-02-09 14:48:36.390 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:48:36.392 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709348 } " 2025-02-09 14:48:36.521 - debug: kecontact.0 (17578) Available max power: 23000.9 2025-02-09 14:48:36.521 - debug: kecontact.0 (17578) power: 23000.9 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:48:36.521 - debug: kecontact.0 (17578) Available surplus: -3413.2 2025-02-09 14:48:36.521 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:48:36.522 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:48:36.522 - info: kecontact.0 (17578) stop charging 2025-02-09 14:48:36.690 - debug: kecontact.0 (17578) Sent "currtime 0 1" to 10.1.4.9:7090 2025-02-09 14:48:36.694 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-OK :done " 2025-02-09 14:48:36.694 - debug: kecontact.0 (17578) Received TCH-OK :done 2025-02-09 14:48:36.991 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:48:36.994 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709348 } " 2025-02-09 14:48:36.995 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:48:51.089 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:48:51.090 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709363 } " 2025-02-09 14:48:51.389 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:48:51.391 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709363 } " 2025-02-09 14:48:51.467 - debug: kecontact.0 (17578) Available max power: 22980.3 2025-02-09 14:48:51.467 - debug: kecontact.0 (17578) power: 22980.3 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:48:51.467 - debug: kecontact.0 (17578) Available surplus: -3412.7999999999997 2025-02-09 14:48:51.689 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:48:51.690 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709363 } " 2025-02-09 14:48:51.691 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:49:06.090 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:49:06.091 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709378 } " 2025-02-09 14:49:06.390 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:49:06.392 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709378 } " 2025-02-09 14:49:06.472 - debug: kecontact.0 (17578) Available max power: 23005.6 2025-02-09 14:49:06.472 - debug: kecontact.0 (17578) power: 23005.6 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:49:06.473 - debug: kecontact.0 (17578) Available surplus: -3354.8 2025-02-09 14:49:06.473 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:49:06.473 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:49:06.690 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:49:06.693 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709378 } " 2025-02-09 14:49:06.693 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:49:21.090 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:49:21.092 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709393 } " 2025-02-09 14:49:21.391 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:49:21.393 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709393 } " 2025-02-09 14:49:21.473 - debug: kecontact.0 (17578) Available max power: 23008.2 2025-02-09 14:49:21.473 - debug: kecontact.0 (17578) power: 23008.2 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:49:21.474 - debug: kecontact.0 (17578) Available surplus: -3351 2025-02-09 14:49:21.691 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:49:21.694 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709393 } " 2025-02-09 14:49:21.694 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:49:36.091 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:49:36.093 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709408 } " 2025-02-09 14:49:36.390 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:49:36.392 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709408 } " 2025-02-09 14:49:36.499 - debug: kecontact.0 (17578) Available max power: 22998.9 2025-02-09 14:49:36.499 - debug: kecontact.0 (17578) power: 22998.9 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:49:36.499 - debug: kecontact.0 (17578) Available surplus: -3351.2999999999997 2025-02-09 14:49:36.499 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:49:36.499 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:49:36.691 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:49:36.694 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709408 } " 2025-02-09 14:49:36.694 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:49:51.092 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:49:51.094 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709423 } " 2025-02-09 14:49:51.393 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:49:51.395 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709423 } " 2025-02-09 14:49:51.474 - debug: kecontact.0 (17578) Available max power: 23004.3 2025-02-09 14:49:51.474 - debug: kecontact.0 (17578) power: 23004.3 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:49:51.474 - debug: kecontact.0 (17578) Available surplus: -3363.5 2025-02-09 14:49:51.693 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:49:51.695 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709423 } " 2025-02-09 14:49:51.695 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:50:06.092 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:50:06.094 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709438 } " 2025-02-09 14:50:06.393 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:50:06.395 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709438 } " 2025-02-09 14:50:06.467 - debug: kecontact.0 (17578) Available max power: 22991.2 2025-02-09 14:50:06.468 - debug: kecontact.0 (17578) power: 22991.2 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:50:06.468 - debug: kecontact.0 (17578) Available surplus: -3361.7000000000003 2025-02-09 14:50:06.468 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:50:06.468 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:50:06.694 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:50:06.696 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709438 } " 2025-02-09 14:50:06.697 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:50:21.094 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:50:21.096 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709453 } " 2025-02-09 14:50:21.394 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:50:21.396 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709453 } " 2025-02-09 14:50:21.471 - debug: kecontact.0 (17578) Available max power: 22954.6 2025-02-09 14:50:21.472 - debug: kecontact.0 (17578) power: 22954.6 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:50:21.472 - debug: kecontact.0 (17578) Available surplus: -3510 2025-02-09 14:50:21.694 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:50:21.696 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709453 } " 2025-02-09 14:50:21.696 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:50:36.094 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:50:36.096 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709468 } " 2025-02-09 14:50:36.394 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:50:36.396 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709468 } " 2025-02-09 14:50:36.471 - debug: kecontact.0 (17578) Available max power: 23024.9 2025-02-09 14:50:36.472 - debug: kecontact.0 (17578) power: 23024.9 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:50:36.472 - debug: kecontact.0 (17578) Available surplus: -3381.4 2025-02-09 14:50:36.472 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:50:36.472 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:50:36.693 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:50:36.695 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709468 } " 2025-02-09 14:50:36.695 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:50:51.094 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:50:51.096 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709483 } " 2025-02-09 14:50:51.395 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:50:51.397 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709483 } " 2025-02-09 14:50:51.474 - debug: kecontact.0 (17578) Available max power: 22998.4 2025-02-09 14:50:51.474 - debug: kecontact.0 (17578) power: 22998.4 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:50:51.474 - debug: kecontact.0 (17578) Available surplus: -3455.9 2025-02-09 14:50:51.695 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:50:51.697 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709483 } " 2025-02-09 14:50:51.698 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:51:06.095 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:51:06.097 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709498 } " 2025-02-09 14:51:06.395 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:51:06.396 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709498 } " 2025-02-09 14:51:06.472 - debug: kecontact.0 (17578) Available max power: 22973.6 2025-02-09 14:51:06.472 - debug: kecontact.0 (17578) power: 22973.6 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:51:06.472 - debug: kecontact.0 (17578) Available surplus: -3482 2025-02-09 14:51:06.472 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:51:06.472 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:51:06.695 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:51:06.699 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709498 } " 2025-02-09 14:51:06.700 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:51:21.095 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:51:21.096 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709513 } " 2025-02-09 14:51:21.395 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:51:21.397 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709513 } " 2025-02-09 14:51:21.478 - debug: kecontact.0 (17578) Available max power: 23014.4 2025-02-09 14:51:21.478 - debug: kecontact.0 (17578) power: 23014.4 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:51:21.479 - debug: kecontact.0 (17578) Available surplus: -3466.6 2025-02-09 14:51:21.696 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:51:21.698 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709513 } " 2025-02-09 14:51:21.699 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:51:36.095 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:51:36.097 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709528 } " 2025-02-09 14:51:36.396 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:51:36.397 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709528 } " 2025-02-09 14:51:36.484 - debug: kecontact.0 (17578) Available max power: 22995.6 2025-02-09 14:51:36.484 - debug: kecontact.0 (17578) power: 22995.6 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:51:36.484 - debug: kecontact.0 (17578) Available surplus: -3458.8 2025-02-09 14:51:36.484 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:51:36.484 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:51:36.696 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:51:36.699 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709528 } " 2025-02-09 14:51:36.699 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:51:51.096 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:51:51.099 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709543 } " 2025-02-09 14:51:51.396 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:51:51.398 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709543 } " 2025-02-09 14:51:51.475 - debug: kecontact.0 (17578) Available max power: 22984.3 2025-02-09 14:51:51.475 - debug: kecontact.0 (17578) power: 22984.3 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:51:51.475 - debug: kecontact.0 (17578) Available surplus: -3423.7 2025-02-09 14:51:51.697 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:51:51.700 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709543 } " 2025-02-09 14:51:51.700 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:52:06.096 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:52:06.099 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709558 } " 2025-02-09 14:52:06.397 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:52:06.400 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709558 } " 2025-02-09 14:52:06.542 - debug: kecontact.0 (17578) Available max power: 23003 2025-02-09 14:52:06.542 - debug: kecontact.0 (17578) power: 23003 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:52:06.542 - debug: kecontact.0 (17578) Available surplus: -3387.7 2025-02-09 14:52:06.542 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:52:06.542 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:52:06.697 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:52:06.700 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709558 } " 2025-02-09 14:52:06.700 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:52:21.097 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:52:21.100 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709573 } " 2025-02-09 14:52:21.397 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:52:21.400 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709573 } " 2025-02-09 14:52:21.486 - debug: kecontact.0 (17578) Available max power: 23004.1 2025-02-09 14:52:21.486 - debug: kecontact.0 (17578) power: 23004.1 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:52:21.487 - debug: kecontact.0 (17578) Available surplus: -3306.2000000000003 2025-02-09 14:52:21.699 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:52:21.701 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709573 } " 2025-02-09 14:52:21.703 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:52:36.097 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:52:36.099 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709588 } " 2025-02-09 14:52:36.397 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:52:36.399 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709588 } " 2025-02-09 14:52:36.475 - debug: kecontact.0 (17578) Available max power: 23006.3 2025-02-09 14:52:36.475 - debug: kecontact.0 (17578) power: 23006.3 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:52:36.475 - debug: kecontact.0 (17578) Available surplus: -3257.1 2025-02-09 14:52:36.475 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:52:36.475 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:52:36.697 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:52:36.700 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709588 } " 2025-02-09 14:52:36.701 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:52:51.097 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:52:51.099 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709603 } " 2025-02-09 14:52:51.397 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:52:51.399 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709603 } " 2025-02-09 14:52:51.472 - debug: kecontact.0 (17578) Available max power: 22854 2025-02-09 14:52:51.472 - debug: kecontact.0 (17578) power: 22854 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:52:51.472 - debug: kecontact.0 (17578) Available surplus: -1050 2025-02-09 14:52:51.698 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:52:51.701 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709603 } " 2025-02-09 14:52:51.702 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:53:06.097 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:53:06.099 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709618 } " 2025-02-09 14:53:06.399 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:53:06.401 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709618 } " 2025-02-09 14:53:06.485 - debug: kecontact.0 (17578) Available max power: 22981.8 2025-02-09 14:53:06.485 - debug: kecontact.0 (17578) power: 22981.8 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:53:06.485 - debug: kecontact.0 (17578) Available surplus: -1034.8 2025-02-09 14:53:06.486 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:53:06.486 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:53:06.699 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:53:06.701 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709618 } " 2025-02-09 14:53:06.702 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:53:21.098 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:53:21.101 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709633 } " 2025-02-09 14:53:21.399 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:53:21.401 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709633 } " 2025-02-09 14:53:21.476 - debug: kecontact.0 (17578) Available max power: 23016.8 2025-02-09 14:53:21.476 - debug: kecontact.0 (17578) power: 23016.8 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:53:21.476 - debug: kecontact.0 (17578) Available surplus: -896.3000000000001 2025-02-09 14:53:21.699 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:53:21.701 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709633 } " 2025-02-09 14:53:21.702 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:53:36.100 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:53:36.102 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709648 } " 2025-02-09 14:53:36.400 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:53:36.402 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709648 } " 2025-02-09 14:53:36.482 - debug: kecontact.0 (17578) Available max power: 23062.1 2025-02-09 14:53:36.482 - debug: kecontact.0 (17578) power: 23062.1 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:53:36.482 - debug: kecontact.0 (17578) Available surplus: -662.1 2025-02-09 14:53:36.483 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:53:36.483 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:53:36.700 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:53:36.702 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709648 } " 2025-02-09 14:53:36.703 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:53:51.100 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:53:51.102 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709663 } " 2025-02-09 14:53:51.400 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:53:51.401 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709663 } " 2025-02-09 14:53:51.485 - debug: kecontact.0 (17578) Available max power: 23075.2 2025-02-09 14:53:51.485 - debug: kecontact.0 (17578) power: 23075.2 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:53:51.485 - debug: kecontact.0 (17578) Available surplus: -475.09999999999997 2025-02-09 14:53:51.700 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:53:51.702 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709663 } " 2025-02-09 14:53:51.703 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:54:06.100 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:54:06.102 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709678 } " 2025-02-09 14:54:06.400 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:54:06.401 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709678 } " 2025-02-09 14:54:06.495 - debug: kecontact.0 (17578) Available max power: 23103.9 2025-02-09 14:54:06.496 - debug: kecontact.0 (17578) power: 23103.9 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:54:06.496 - debug: kecontact.0 (17578) Available surplus: -200.9 2025-02-09 14:54:06.496 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:54:06.496 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:54:06.700 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:54:06.703 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709678 } " 2025-02-09 14:54:06.703 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:54:21.100 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:54:21.103 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709693 } " 2025-02-09 14:54:21.402 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:54:21.403 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709693 } " 2025-02-09 14:54:21.483 - debug: kecontact.0 (17578) Available max power: 23111.8 2025-02-09 14:54:21.483 - debug: kecontact.0 (17578) power: 23111.8 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:54:21.483 - debug: kecontact.0 (17578) Available surplus: 396.90000000000003 2025-02-09 14:54:21.702 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:54:21.705 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709693 } " 2025-02-09 14:54:21.705 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:54:36.100 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:54:36.102 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709708 } " 2025-02-09 14:54:36.400 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:54:36.401 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709708 } " 2025-02-09 14:54:36.479 - debug: kecontact.0 (17578) Available max power: 23030.5 2025-02-09 14:54:36.479 - debug: kecontact.0 (17578) power: 23030.5 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:54:36.479 - debug: kecontact.0 (17578) Available surplus: 824.5 2025-02-09 14:54:36.479 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:54:36.479 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:54:36.700 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:54:36.702 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709708 } " 2025-02-09 14:54:36.702 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:54:51.100 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:54:51.102 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709723 } " 2025-02-09 14:54:51.400 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:54:51.402 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709723 } " 2025-02-09 14:54:51.480 - debug: kecontact.0 (17578) Available max power: 23036.1 2025-02-09 14:54:51.481 - debug: kecontact.0 (17578) power: 23036.1 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:54:51.481 - debug: kecontact.0 (17578) Available surplus: 1124.1 2025-02-09 14:54:51.700 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:54:51.703 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709723 } " 2025-02-09 14:54:51.703 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:55:06.100 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:55:06.103 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709738 } " 2025-02-09 14:55:06.400 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:55:06.402 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709738 } " 2025-02-09 14:55:06.518 - debug: kecontact.0 (17578) Available max power: 23111 2025-02-09 14:55:06.519 - debug: kecontact.0 (17578) power: 23111 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:55:06.519 - debug: kecontact.0 (17578) Available surplus: 1472.4 2025-02-09 14:55:06.519 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:55:06.519 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:55:06.701 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:55:06.703 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709738 } " 2025-02-09 14:55:06.703 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:55:21.099 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:55:21.101 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709753 } " 2025-02-09 14:55:21.400 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:55:21.403 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709753 } " 2025-02-09 14:55:21.482 - debug: kecontact.0 (17578) Available max power: 23106.2 2025-02-09 14:55:21.483 - debug: kecontact.0 (17578) power: 23106.2 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:55:21.483 - debug: kecontact.0 (17578) Available surplus: 1678.5 2025-02-09 14:55:21.700 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:55:21.703 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709753 } " 2025-02-09 14:55:21.704 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:55:36.100 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:55:36.102 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709768 } " 2025-02-09 14:55:36.401 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:55:36.403 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709768 } " 2025-02-09 14:55:36.524 - debug: kecontact.0 (17578) Available max power: 22814.89 2025-02-09 14:55:36.524 - debug: kecontact.0 (17578) power: 22814.89 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:55:36.524 - debug: kecontact.0 (17578) Available surplus: 4065.7899999999995 2025-02-09 14:55:36.524 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:55:36.524 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:55:36.702 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:55:36.704 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709768 } " 2025-02-09 14:55:36.704 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:55:51.100 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:55:51.102 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709783 } " 2025-02-09 14:55:51.402 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:55:51.403 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709783 } " 2025-02-09 14:55:51.481 - debug: kecontact.0 (17578) Available max power: 23101.94 2025-02-09 14:55:51.481 - debug: kecontact.0 (17578) power: 23101.94 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:55:51.481 - debug: kecontact.0 (17578) Available surplus: 4214.139999999999 2025-02-09 14:55:51.702 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:55:51.705 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709783 } " 2025-02-09 14:55:51.706 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:56:06.101 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:56:06.103 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709798 } " 2025-02-09 14:56:06.401 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:56:06.404 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709798 } " 2025-02-09 14:56:06.482 - debug: kecontact.0 (17578) Available max power: 23097.71 2025-02-09 14:56:06.482 - debug: kecontact.0 (17578) power: 23097.71 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:56:06.482 - debug: kecontact.0 (17578) Available surplus: 4325.71 2025-02-09 14:56:06.482 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:56:06.482 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:56:06.702 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:56:06.705 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709798 } " 2025-02-09 14:56:06.705 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:56:21.101 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:56:21.104 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709813 } " 2025-02-09 14:56:21.401 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:56:21.404 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709813 } " 2025-02-09 14:56:21.493 - debug: kecontact.0 (17578) Available max power: 23034.82 2025-02-09 14:56:21.493 - debug: kecontact.0 (17578) power: 23034.82 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:56:21.493 - debug: kecontact.0 (17578) Available surplus: 4325.42 2025-02-09 14:56:21.701 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:56:21.704 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709813 } " 2025-02-09 14:56:21.704 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:56:36.102 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:56:36.105 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 5, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 32000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 709828 } " 2025-02-09 14:56:36.401 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:56:36.403 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709828 } " 2025-02-09 14:56:36.502 - debug: kecontact.0 (17578) Available max power: 23007.87 2025-02-09 14:56:36.503 - debug: kecontact.0 (17578) power: 23007.87 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:56:36.503 - debug: kecontact.0 (17578) Available surplus: 4289.17 2025-02-09 14:56:36.503 - debug: kecontact.0 (17578) wallbox set to charging maximum of 32000 mA 2025-02-09 14:56:36.503 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:56:36.702 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:56:36.705 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709828 } " 2025-02-09 14:56:36.705 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:56:43.511 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Plug": 1}" 2025-02-09 14:56:43.579 - info: kecontact.0 (17578) vehicle unplugged from wallbox 2025-02-09 14:56:43.579 - info: kecontact.0 (17578) updating X2 for switch of phases from 1 to 0... 2025-02-09 14:56:43.580 - debug: kecontact.0 (17578) Sent "x2 0" to 10.1.4.9:7090 2025-02-09 14:56:43.590 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-OK :done " 2025-02-09 14:56:43.590 - debug: kecontact.0 (17578) Received TCH-OK :done 2025-02-09 14:56:51.103 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:56:51.105 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 1, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 709843 } " 2025-02-09 14:56:51.403 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:56:51.404 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709843 } " 2025-02-09 14:56:51.483 - debug: kecontact.0 (17578) Available max power: 22979.08 2025-02-09 14:56:51.483 - debug: kecontact.0 (17578) power: 22979.08 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:56:51.484 - debug: kecontact.0 (17578) Available surplus: 4206.08 2025-02-09 14:56:51.703 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:56:51.706 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709843 } " 2025-02-09 14:56:51.706 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:57:03.521 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Plug": 3}" 2025-02-09 14:57:03.690 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Plug": 1}" 2025-02-09 14:57:06.103 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:57:06.106 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 1, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 709858 } " 2025-02-09 14:57:06.404 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:57:06.406 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709858 } " 2025-02-09 14:57:06.494 - debug: kecontact.0 (17578) Available max power: 22936 2025-02-09 14:57:06.494 - debug: kecontact.0 (17578) power: 22936 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:57:06.494 - debug: kecontact.0 (17578) Available surplus: 4189.7 2025-02-09 14:57:06.494 - info: kecontact.0 (17578) updating X2 for switch of phases from 0 to 1... 2025-02-09 14:57:06.494 - debug: kecontact.0 (17578) wallbox set to charging maximum of 16000 mA 2025-02-09 14:57:06.494 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:57:06.494 - info: kecontact.0 (17578) stop charging 2025-02-09 14:57:06.704 - debug: kecontact.0 (17578) Sent "currtime 0 1" to 10.1.4.9:7090 2025-02-09 14:57:06.705 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-OK :done " 2025-02-09 14:57:06.705 - debug: kecontact.0 (17578) Received TCH-OK :done 2025-02-09 14:57:07.004 - debug: kecontact.0 (17578) Sent "x2 1" to 10.1.4.9:7090 2025-02-09 14:57:07.005 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-ERR:X2 : not allowed now " 2025-02-09 14:57:07.006 - error: kecontact.0 (17578) Error received from wallbox: TCH-ERR:X2 : not allowed now 2025-02-09 14:57:07.304 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:57:07.307 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709859 } " 2025-02-09 14:57:07.307 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:57:21.105 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:57:21.108 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 709873 } " 2025-02-09 14:57:21.405 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:57:21.408 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709873 } " 2025-02-09 14:57:21.483 - debug: kecontact.0 (17578) Available max power: 23093.15 2025-02-09 14:57:21.484 - debug: kecontact.0 (17578) power: 23093.15 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:57:21.484 - debug: kecontact.0 (17578) Available surplus: 4287.549999999999 2025-02-09 14:57:21.706 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:57:21.708 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709873 } " 2025-02-09 14:57:21.709 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:57:23.712 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Plug": 3}" 2025-02-09 14:57:23.950 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Plug": 1}" 2025-02-09 14:57:36.105 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:57:36.108 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 709888 } " 2025-02-09 14:57:36.405 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:57:36.407 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709888 } " 2025-02-09 14:57:36.502 - debug: kecontact.0 (17578) Available max power: 23028.15 2025-02-09 14:57:36.503 - debug: kecontact.0 (17578) power: 23028.15 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:57:36.503 - debug: kecontact.0 (17578) Available surplus: 4352.25 2025-02-09 14:57:36.503 - info: kecontact.0 (17578) updating X2 for switch of phases from 0 to 1... 2025-02-09 14:57:36.503 - debug: kecontact.0 (17578) wallbox set to charging maximum of 16000 mA 2025-02-09 14:57:36.503 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:57:36.705 - debug: kecontact.0 (17578) Sent "x2 1" to 10.1.4.9:7090 2025-02-09 14:57:36.706 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-ERR:X2 : not allowed now " 2025-02-09 14:57:36.706 - error: kecontact.0 (17578) Error received from wallbox: TCH-ERR:X2 : not allowed now 2025-02-09 14:57:37.005 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:57:37.007 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709888 } " 2025-02-09 14:57:37.007 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:57:43.915 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Plug": 3}" 2025-02-09 14:57:44.152 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Plug": 1}" 2025-02-09 14:57:51.105 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:57:51.108 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 709903 } " 2025-02-09 14:57:51.406 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:57:51.408 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709903 } " 2025-02-09 14:57:51.490 - debug: kecontact.0 (17578) Available max power: 22957.79 2025-02-09 14:57:51.490 - debug: kecontact.0 (17578) power: 22957.79 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:57:51.490 - debug: kecontact.0 (17578) Available surplus: 4251.19 2025-02-09 14:57:51.706 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:57:51.708 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709903 } " 2025-02-09 14:57:51.708 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:58:06.105 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:58:06.107 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 709918 } " 2025-02-09 14:58:06.405 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:58:06.408 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709918 } " 2025-02-09 14:58:06.489 - debug: kecontact.0 (17578) Available max power: 22400.7 2025-02-09 14:58:06.489 - debug: kecontact.0 (17578) power: 22400.7 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 32000 2025-02-09 14:58:06.489 - debug: kecontact.0 (17578) Available surplus: 3652.7 2025-02-09 14:58:06.489 - info: kecontact.0 (17578) updating X2 for switch of phases from 0 to 1... 2025-02-09 14:58:06.489 - debug: kecontact.0 (17578) wallbox set to charging maximum of 16000 mA 2025-02-09 14:58:06.489 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:58:06.705 - debug: kecontact.0 (17578) Sent "x2 1" to 10.1.4.9:7090 2025-02-09 14:58:06.707 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-ERR:X2 : not allowed now " 2025-02-09 14:58:06.707 - error: kecontact.0 (17578) Error received from wallbox: TCH-ERR:X2 : not allowed now 2025-02-09 14:58:07.005 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:58:07.007 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709918 } " 2025-02-09 14:58:07.008 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:58:21.105 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:58:21.106 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 709933 } " 2025-02-09 14:58:21.405 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:58:21.407 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709933 } " 2025-02-09 14:58:21.487 - debug: kecontact.0 (17578) Available max power: 22903.9 2025-02-09 14:58:21.488 - debug: kecontact.0 (17578) power: 22903.9 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:58:21.488 - debug: kecontact.0 (17578) Available surplus: 4115.599999999999 2025-02-09 14:58:21.706 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:58:21.709 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709933 } " 2025-02-09 14:58:21.710 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:58:36.105 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:58:36.107 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 709948 } " 2025-02-09 14:58:36.405 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:58:36.408 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709948 } " 2025-02-09 14:58:36.498 - debug: kecontact.0 (17578) Available max power: 22947.19 2025-02-09 14:58:36.498 - debug: kecontact.0 (17578) power: 22947.19 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:58:36.498 - debug: kecontact.0 (17578) Available surplus: 4117.19 2025-02-09 14:58:36.498 - info: kecontact.0 (17578) updating X2 for switch of phases from 0 to 1... 2025-02-09 14:58:36.498 - debug: kecontact.0 (17578) wallbox set to charging maximum of 16000 mA 2025-02-09 14:58:36.498 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:58:36.705 - debug: kecontact.0 (17578) Sent "x2 1" to 10.1.4.9:7090 2025-02-09 14:58:36.706 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-ERR:X2 : not allowed now " 2025-02-09 14:58:36.706 - error: kecontact.0 (17578) Error received from wallbox: TCH-ERR:X2 : not allowed now 2025-02-09 14:58:37.005 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:58:37.007 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709948 } " 2025-02-09 14:58:37.008 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:58:51.105 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:58:51.107 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 709963 } " 2025-02-09 14:58:51.405 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:58:51.407 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709963 } " 2025-02-09 14:58:51.479 - debug: kecontact.0 (17578) Available max power: 22961.85 2025-02-09 14:58:51.479 - debug: kecontact.0 (17578) power: 22961.85 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:58:51.480 - debug: kecontact.0 (17578) Available surplus: 4044.35 2025-02-09 14:58:51.705 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:58:51.707 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709963 } " 2025-02-09 14:58:51.707 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:59:06.105 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:59:06.106 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 709978 } " 2025-02-09 14:59:06.405 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:59:06.408 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709978 } " 2025-02-09 14:59:06.506 - debug: kecontact.0 (17578) Available max power: 22996.5 2025-02-09 14:59:06.506 - debug: kecontact.0 (17578) power: 22996.5 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:59:06.506 - debug: kecontact.0 (17578) Available surplus: 4037.5 2025-02-09 14:59:06.506 - info: kecontact.0 (17578) updating X2 for switch of phases from 0 to 1... 2025-02-09 14:59:06.506 - debug: kecontact.0 (17578) wallbox set to charging maximum of 16000 mA 2025-02-09 14:59:06.506 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:59:06.706 - debug: kecontact.0 (17578) Sent "x2 1" to 10.1.4.9:7090 2025-02-09 14:59:06.707 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-ERR:X2 : not allowed now " 2025-02-09 14:59:06.707 - error: kecontact.0 (17578) Error received from wallbox: TCH-ERR:X2 : not allowed now 2025-02-09 14:59:07.006 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:59:07.008 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709978 } " 2025-02-09 14:59:07.008 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:59:21.105 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:59:21.106 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 709993 } " 2025-02-09 14:59:21.404 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:59:21.406 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 709993 } " 2025-02-09 14:59:21.490 - debug: kecontact.0 (17578) Available max power: 22986.5 2025-02-09 14:59:21.490 - debug: kecontact.0 (17578) power: 22986.5 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:59:21.490 - debug: kecontact.0 (17578) Available surplus: 4063.1 2025-02-09 14:59:21.705 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:59:21.708 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 709993 } " 2025-02-09 14:59:21.708 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:59:36.105 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:59:36.107 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 710008 } " 2025-02-09 14:59:36.405 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:59:36.408 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710008 } " 2025-02-09 14:59:36.498 - debug: kecontact.0 (17578) Available max power: 22989.93 2025-02-09 14:59:36.498 - debug: kecontact.0 (17578) power: 22989.93 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:59:36.498 - debug: kecontact.0 (17578) Available surplus: 4101.2300000000005 2025-02-09 14:59:36.498 - info: kecontact.0 (17578) updating X2 for switch of phases from 0 to 1... 2025-02-09 14:59:36.498 - debug: kecontact.0 (17578) wallbox set to charging maximum of 16000 mA 2025-02-09 14:59:36.498 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 14:59:36.705 - debug: kecontact.0 (17578) Sent "x2 1" to 10.1.4.9:7090 2025-02-09 14:59:36.706 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-ERR:X2 : not allowed now " 2025-02-09 14:59:36.706 - error: kecontact.0 (17578) Error received from wallbox: TCH-ERR:X2 : not allowed now 2025-02-09 14:59:37.005 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:59:37.007 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710008 } " 2025-02-09 14:59:37.007 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 14:59:51.105 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 14:59:51.107 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 710023 } " 2025-02-09 14:59:51.405 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 14:59:51.407 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710023 } " 2025-02-09 14:59:51.528 - debug: kecontact.0 (17578) Available max power: 22996.41 2025-02-09 14:59:51.528 - debug: kecontact.0 (17578) power: 22996.41 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 14:59:51.528 - debug: kecontact.0 (17578) Available surplus: 4134.21 2025-02-09 14:59:51.706 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 14:59:51.708 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710023 } " 2025-02-09 14:59:51.708 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:00:06.105 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:00:06.108 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 710038 } " 2025-02-09 15:00:06.407 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:00:06.409 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710038 } " 2025-02-09 15:00:06.527 - debug: kecontact.0 (17578) Available max power: 22961.12 2025-02-09 15:00:06.527 - debug: kecontact.0 (17578) power: 22961.12 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:00:06.527 - debug: kecontact.0 (17578) Available surplus: 4116.5199999999995 2025-02-09 15:00:06.528 - info: kecontact.0 (17578) updating X2 for switch of phases from 0 to 1... 2025-02-09 15:00:06.528 - debug: kecontact.0 (17578) wallbox set to charging maximum of 16000 mA 2025-02-09 15:00:06.528 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 15:00:06.707 - debug: kecontact.0 (17578) Sent "x2 1" to 10.1.4.9:7090 2025-02-09 15:00:06.708 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-ERR:X2 : not allowed now " 2025-02-09 15:00:06.708 - error: kecontact.0 (17578) Error received from wallbox: TCH-ERR:X2 : not allowed now 2025-02-09 15:00:07.008 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:00:07.011 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710038 } " 2025-02-09 15:00:07.013 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:00:21.105 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:00:21.107 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 710053 } " 2025-02-09 15:00:21.406 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:00:21.408 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710053 } " 2025-02-09 15:00:21.516 - debug: kecontact.0 (17578) Available max power: 22988.51 2025-02-09 15:00:21.516 - debug: kecontact.0 (17578) power: 22988.51 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:00:21.516 - debug: kecontact.0 (17578) Available surplus: 4137.41 2025-02-09 15:00:21.707 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:00:21.710 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710053 } " 2025-02-09 15:00:21.710 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:00:36.106 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:00:36.109 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 710068 } " 2025-02-09 15:00:36.406 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:00:36.408 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710068 } " 2025-02-09 15:00:36.500 - debug: kecontact.0 (17578) Available max power: 22995.48 2025-02-09 15:00:36.500 - debug: kecontact.0 (17578) power: 22995.48 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:00:36.501 - debug: kecontact.0 (17578) Available surplus: 4171.78 2025-02-09 15:00:36.501 - info: kecontact.0 (17578) updating X2 for switch of phases from 0 to 1... 2025-02-09 15:00:36.501 - debug: kecontact.0 (17578) wallbox set to charging maximum of 16000 mA 2025-02-09 15:00:36.501 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 15:00:36.707 - debug: kecontact.0 (17578) Sent "x2 1" to 10.1.4.9:7090 2025-02-09 15:00:36.710 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-ERR:X2 : not allowed now " 2025-02-09 15:00:36.710 - error: kecontact.0 (17578) Error received from wallbox: TCH-ERR:X2 : not allowed now 2025-02-09 15:00:37.008 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:00:37.010 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710068 } " 2025-02-09 15:00:37.011 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:00:51.106 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:00:51.107 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 710083 } " 2025-02-09 15:00:51.406 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:00:51.408 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710083 } " 2025-02-09 15:00:51.482 - debug: kecontact.0 (17578) Available max power: 22987.45 2025-02-09 15:00:51.482 - debug: kecontact.0 (17578) power: 22987.45 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:00:51.483 - debug: kecontact.0 (17578) Available surplus: 4178.65 2025-02-09 15:00:51.707 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:00:51.709 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710083 } " 2025-02-09 15:00:51.710 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:01:06.106 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:01:06.107 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 710098 } " 2025-02-09 15:01:06.406 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:01:06.408 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710098 } " 2025-02-09 15:01:06.498 - debug: kecontact.0 (17578) Available max power: 23000.28 2025-02-09 15:01:06.498 - debug: kecontact.0 (17578) power: 23000.28 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:01:06.498 - debug: kecontact.0 (17578) Available surplus: 4186.88 2025-02-09 15:01:06.498 - info: kecontact.0 (17578) updating X2 for switch of phases from 0 to 1... 2025-02-09 15:01:06.498 - debug: kecontact.0 (17578) wallbox set to charging maximum of 16000 mA 2025-02-09 15:01:06.498 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 15:01:06.707 - debug: kecontact.0 (17578) Sent "x2 1" to 10.1.4.9:7090 2025-02-09 15:01:06.708 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-ERR:X2 : not allowed now " 2025-02-09 15:01:06.709 - error: kecontact.0 (17578) Error received from wallbox: TCH-ERR:X2 : not allowed now 2025-02-09 15:01:07.007 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:01:07.010 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710098 } " 2025-02-09 15:01:07.010 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:01:21.106 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:01:21.108 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 710113 } " 2025-02-09 15:01:21.406 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:01:21.408 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710113 } " 2025-02-09 15:01:21.492 - debug: kecontact.0 (17578) Available max power: 22966.59 2025-02-09 15:01:21.492 - debug: kecontact.0 (17578) power: 22966.59 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:01:21.492 - debug: kecontact.0 (17578) Available surplus: 4149.99 2025-02-09 15:01:21.706 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:01:21.708 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710113 } " 2025-02-09 15:01:21.708 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:01:36.106 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:01:36.109 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 710128 } " 2025-02-09 15:01:36.407 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:01:36.408 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710128 } " 2025-02-09 15:01:36.503 - debug: kecontact.0 (17578) Available max power: 22974.79 2025-02-09 15:01:36.503 - debug: kecontact.0 (17578) power: 22974.79 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:01:36.503 - debug: kecontact.0 (17578) Available surplus: 4183.19 2025-02-09 15:01:36.503 - info: kecontact.0 (17578) updating X2 for switch of phases from 0 to 1... 2025-02-09 15:01:36.503 - debug: kecontact.0 (17578) wallbox set to charging maximum of 16000 mA 2025-02-09 15:01:36.503 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 15:01:36.707 - debug: kecontact.0 (17578) Sent "x2 1" to 10.1.4.9:7090 2025-02-09 15:01:36.709 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-ERR:X2 : not allowed now " 2025-02-09 15:01:36.709 - error: kecontact.0 (17578) Error received from wallbox: TCH-ERR:X2 : not allowed now 2025-02-09 15:01:37.007 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:01:37.010 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710128 } " 2025-02-09 15:01:37.011 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:01:51.108 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:01:51.110 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 710143 } " 2025-02-09 15:01:51.408 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:01:51.410 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710143 } " 2025-02-09 15:01:51.484 - debug: kecontact.0 (17578) Available max power: 23010.36 2025-02-09 15:01:51.484 - debug: kecontact.0 (17578) power: 23010.36 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:01:51.484 - debug: kecontact.0 (17578) Available surplus: 4107.0599999999995 2025-02-09 15:01:51.708 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:01:51.711 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710143 } " 2025-02-09 15:01:51.711 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:02:06.109 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:02:06.111 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 0, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 0, "Serial": "26663654", "Sec": 710158 } " 2025-02-09 15:02:06.409 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:02:06.411 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710158 } " 2025-02-09 15:02:06.532 - debug: kecontact.0 (17578) Available max power: 23041.59 2025-02-09 15:02:06.532 - debug: kecontact.0 (17578) power: 23041.59 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:02:06.532 - debug: kecontact.0 (17578) Available surplus: 4189.6900000000005 2025-02-09 15:02:06.532 - info: kecontact.0 (17578) updating X2 for switch of phases from 0 to 1... 2025-02-09 15:02:06.532 - debug: kecontact.0 (17578) wallbox set to charging maximum of 16000 mA 2025-02-09 15:02:06.532 - debug: kecontact.0 (17578) No charging due to interupted charging station 2025-02-09 15:02:06.710 - debug: kecontact.0 (17578) Sent "x2 1" to 10.1.4.9:7090 2025-02-09 15:02:06.711 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "TCH-OK :done " 2025-02-09 15:02:06.712 - debug: kecontact.0 (17578) Received TCH-OK :done 2025-02-09 15:02:07.010 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:02:07.013 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710158 } " 2025-02-09 15:02:07.013 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:02:21.109 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:02:21.111 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 1, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 32000, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 710173 } " 2025-02-09 15:02:21.411 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:02:21.413 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710173 } " 2025-02-09 15:02:21.498 - debug: kecontact.0 (17578) Available max power: 23003.15 2025-02-09 15:02:21.498 - debug: kecontact.0 (17578) power: 23003.15 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:02:21.498 - debug: kecontact.0 (17578) Available surplus: 4234.75 2025-02-09 15:02:21.711 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:02:21.713 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710173 } " 2025-02-09 15:02:21.713 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:02:24.586 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{"Plug": 0}" 2025-02-09 15:02:24.638 - debug: kecontact.0 (17578) set automatic.pauseWallbox to false 2025-02-09 15:02:36.110 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:02:36.112 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 0, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 0, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 710188 } " 2025-02-09 15:02:36.410 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:02:36.412 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710188 } " 2025-02-09 15:02:36.505 - debug: kecontact.0 (17578) Available max power: 23014.81 2025-02-09 15:02:36.505 - debug: kecontact.0 (17578) power: 23014.81 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:02:36.505 - debug: kecontact.0 (17578) Available surplus: 4046.61 2025-02-09 15:02:36.505 - debug: kecontact.0 (17578) no switching to default phases because of minimum time between switching (stopCharging): Sun Feb 09 2025 15:02:06 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 15:02:36.505 - debug: kecontact.0 (17578) not enough power for charging ... 2025-02-09 15:02:36.710 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:02:36.712 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710188 } " 2025-02-09 15:02:36.712 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:02:51.111 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:02:51.113 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 0, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 0, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 710203 } " 2025-02-09 15:02:51.411 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:02:51.413 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710203 } " 2025-02-09 15:02:51.490 - debug: kecontact.0 (17578) Available max power: 23043.44 2025-02-09 15:02:51.490 - debug: kecontact.0 (17578) power: 23043.44 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:02:51.490 - debug: kecontact.0 (17578) Available surplus: 4050.04 2025-02-09 15:02:51.712 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:02:51.714 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710203 } " 2025-02-09 15:02:51.715 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:03:06.112 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:03:06.114 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 0, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 0, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 710218 } " 2025-02-09 15:03:06.412 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:03:06.413 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710218 } " 2025-02-09 15:03:06.511 - debug: kecontact.0 (17578) Available max power: 23115.29 2025-02-09 15:03:06.511 - debug: kecontact.0 (17578) power: 23115.29 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 34000 2025-02-09 15:03:06.511 - debug: kecontact.0 (17578) Available surplus: 4206.89 2025-02-09 15:03:06.512 - debug: kecontact.0 (17578) no switching to default phases because of minimum time between switching (stopCharging): Sun Feb 09 2025 15:02:06 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 15:03:06.512 - debug: kecontact.0 (17578) not enough power for charging ... 2025-02-09 15:03:06.712 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:03:06.715 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710218 } " 2025-02-09 15:03:06.715 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:03:21.113 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:03:21.115 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 0, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 0, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 710233 } " 2025-02-09 15:03:21.414 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:03:21.416 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710233 } " 2025-02-09 15:03:21.487 - debug: kecontact.0 (17578) Available max power: 23002.24 2025-02-09 15:03:21.487 - debug: kecontact.0 (17578) power: 23002.24 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:03:21.487 - debug: kecontact.0 (17578) Available surplus: 4132.639999999999 2025-02-09 15:03:21.715 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:03:21.719 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710233 } " 2025-02-09 15:03:21.719 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:03:36.114 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:03:36.117 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 0, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 0, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 710248 } " 2025-02-09 15:03:36.414 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:03:36.415 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710248 } " 2025-02-09 15:03:36.489 - debug: kecontact.0 (17578) Available max power: 22998.3 2025-02-09 15:03:36.489 - debug: kecontact.0 (17578) power: 22998.3 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:03:36.489 - debug: kecontact.0 (17578) Available surplus: 4116.5 2025-02-09 15:03:36.490 - debug: kecontact.0 (17578) no switching to default phases because of minimum time between switching (stopCharging): Sun Feb 09 2025 15:02:06 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 15:03:36.490 - debug: kecontact.0 (17578) not enough power for charging ... 2025-02-09 15:03:36.714 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:03:36.716 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710248 } " 2025-02-09 15:03:36.716 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:03:51.115 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:03:51.116 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 0, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 0, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 710263 } " 2025-02-09 15:03:51.415 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:03:51.419 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710263 } " 2025-02-09 15:03:51.553 - debug: kecontact.0 (17578) Available max power: 23010.3 2025-02-09 15:03:51.553 - debug: kecontact.0 (17578) power: 23010.3 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:03:51.553 - debug: kecontact.0 (17578) Available surplus: 4097.5 2025-02-09 15:03:51.716 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:03:51.720 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710263 } " 2025-02-09 15:03:51.720 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:04:06.116 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:04:06.118 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 0, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 0, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 710278 } " 2025-02-09 15:04:06.417 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:04:06.418 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710278 } " 2025-02-09 15:04:06.526 - debug: kecontact.0 (17578) Available max power: 23023.53 2025-02-09 15:04:06.526 - debug: kecontact.0 (17578) power: 23023.53 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:04:06.526 - debug: kecontact.0 (17578) Available surplus: 4105.73 2025-02-09 15:04:06.526 - debug: kecontact.0 (17578) no switching to default phases because of minimum time between switching (stopCharging): Sun Feb 09 2025 15:02:06 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 15:04:06.526 - debug: kecontact.0 (17578) not enough power for charging ... 2025-02-09 15:04:06.717 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:04:06.720 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710278 } " 2025-02-09 15:04:06.720 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:04:21.117 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:04:21.119 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 0, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 0, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 710293 } " 2025-02-09 15:04:21.418 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:04:21.420 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710293 } " 2025-02-09 15:04:21.513 - debug: kecontact.0 (17578) Available max power: 23014.7 2025-02-09 15:04:21.513 - debug: kecontact.0 (17578) power: 23014.7 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:04:21.513 - debug: kecontact.0 (17578) Available surplus: 4138.5 2025-02-09 15:04:21.718 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:04:21.720 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710293 } " 2025-02-09 15:04:21.721 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:04:36.118 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:04:36.121 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 0, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 0, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 710308 } " 2025-02-09 15:04:36.418 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:04:36.420 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710308 } " 2025-02-09 15:04:36.534 - debug: kecontact.0 (17578) Available max power: 23005.13 2025-02-09 15:04:36.534 - debug: kecontact.0 (17578) power: 23005.13 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:04:36.534 - debug: kecontact.0 (17578) Available surplus: 4103.43 2025-02-09 15:04:36.534 - debug: kecontact.0 (17578) no switching to default phases because of minimum time between switching (stopCharging): Sun Feb 09 2025 15:02:06 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 15:04:36.534 - debug: kecontact.0 (17578) not enough power for charging ... 2025-02-09 15:04:36.719 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:04:36.721 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710308 } " 2025-02-09 15:04:36.721 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:04:51.119 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:04:51.121 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 0, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 0, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 710323 } " 2025-02-09 15:04:51.420 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:04:51.422 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710323 } " 2025-02-09 15:04:51.505 - debug: kecontact.0 (17578) Available max power: 23001.34 2025-02-09 15:04:51.506 - debug: kecontact.0 (17578) power: 23001.34 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:04:51.506 - debug: kecontact.0 (17578) Available surplus: 4152.54 2025-02-09 15:04:51.720 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:04:51.723 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710323 } " 2025-02-09 15:04:51.724 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:05:06.119 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:05:06.121 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 0, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 0, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 710338 } " 2025-02-09 15:05:06.419 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:05:06.421 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710338 } " 2025-02-09 15:05:06.501 - debug: kecontact.0 (17578) Available max power: 23004.28 2025-02-09 15:05:06.501 - debug: kecontact.0 (17578) power: 23004.28 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:05:06.501 - debug: kecontact.0 (17578) Available surplus: 4151.88 2025-02-09 15:05:06.501 - debug: kecontact.0 (17578) no switching to default phases because of minimum time between switching (stopCharging): Sun Feb 09 2025 15:02:06 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 15:05:06.501 - debug: kecontact.0 (17578) not enough power for charging ... 2025-02-09 15:05:06.720 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:05:06.721 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710338 } " 2025-02-09 15:05:06.722 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:05:21.120 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:05:21.122 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 0, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 0, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 710353 } " 2025-02-09 15:05:21.420 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:05:21.423 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710353 } " 2025-02-09 15:05:21.506 - debug: kecontact.0 (17578) Available max power: 23026.01 2025-02-09 15:05:21.506 - debug: kecontact.0 (17578) power: 23026.01 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:05:21.506 - debug: kecontact.0 (17578) Available surplus: 4156.21 2025-02-09 15:05:21.720 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:05:21.723 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710353 } " 2025-02-09 15:05:21.723 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:05:36.121 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:05:36.124 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 0, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 0, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 710368 } " 2025-02-09 15:05:36.421 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:05:36.423 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710368 } " 2025-02-09 15:05:36.500 - debug: kecontact.0 (17578) Available max power: 23037.3 2025-02-09 15:05:36.500 - debug: kecontact.0 (17578) power: 23037.3 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:05:36.501 - debug: kecontact.0 (17578) Available surplus: 4225 2025-02-09 15:05:36.501 - debug: kecontact.0 (17578) no switching to default phases because of minimum time between switching (stopCharging): Sun Feb 09 2025 15:02:06 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 15:05:36.501 - debug: kecontact.0 (17578) not enough power for charging ... 2025-02-09 15:05:36.721 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:05:36.723 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710368 } " 2025-02-09 15:05:36.723 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:05:51.122 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:05:51.124 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 0, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 0, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 710383 } " 2025-02-09 15:05:51.422 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:05:51.423 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710383 } " 2025-02-09 15:05:51.494 - debug: kecontact.0 (17578) Available max power: 22997.85 2025-02-09 15:05:51.494 - debug: kecontact.0 (17578) power: 22997.85 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:05:51.494 - debug: kecontact.0 (17578) Available surplus: 4157.25 2025-02-09 15:05:51.722 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:05:51.725 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710383 } " 2025-02-09 15:05:51.725 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:06:06.122 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:06:06.125 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 0, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 0, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 710398 } " 2025-02-09 15:06:06.423 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:06:06.425 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710398 } " 2025-02-09 15:06:06.508 - debug: kecontact.0 (17578) Available max power: 23003.11 2025-02-09 15:06:06.508 - debug: kecontact.0 (17578) power: 23003.11 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:06:06.508 - debug: kecontact.0 (17578) Available surplus: 4097.11 2025-02-09 15:06:06.508 - debug: kecontact.0 (17578) no switching to default phases because of minimum time between switching (stopCharging): Sun Feb 09 2025 15:02:06 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 15:06:06.508 - debug: kecontact.0 (17578) not enough power for charging ... 2025-02-09 15:06:06.724 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:06:06.727 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710398 } " 2025-02-09 15:06:06.727 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:06:21.122 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:06:21.125 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 0, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 0, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 710413 } " 2025-02-09 15:06:21.422 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:06:21.424 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710413 } " 2025-02-09 15:06:21.502 - debug: kecontact.0 (17578) Available max power: 22982.02 2025-02-09 15:06:21.503 - debug: kecontact.0 (17578) power: 22982.02 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:06:21.503 - debug: kecontact.0 (17578) Available surplus: 4044.12 2025-02-09 15:06:21.723 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:06:21.726 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710413 } " 2025-02-09 15:06:21.726 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:06:36.123 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:06:36.125 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 0, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 0, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 710428 } " 2025-02-09 15:06:36.423 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:06:36.425 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710428 } " 2025-02-09 15:06:36.501 - debug: kecontact.0 (17578) Available max power: 22993.06 2025-02-09 15:06:36.501 - debug: kecontact.0 (17578) power: 22993.06 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:06:36.501 - debug: kecontact.0 (17578) Available surplus: 4044.96 2025-02-09 15:06:36.501 - debug: kecontact.0 (17578) no switching to default phases because of minimum time between switching (stopCharging): Sun Feb 09 2025 15:02:06 GMT+0100 (Mitteleuropäische Normalzeit) 2025-02-09 15:06:36.501 - debug: kecontact.0 (17578) not enough power for charging ... 2025-02-09 15:06:36.723 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:06:36.725 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710428 } " 2025-02-09 15:06:36.726 - debug: kecontact.0 (17578) History ID received: 00 2025-02-09 15:06:51.124 - debug: kecontact.0 (17578) Sent "report 2" to 10.1.4.9:7090 2025-02-09 15:06:51.126 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "2", "State": 5, "Error1": 0, "Error2": 0, "Plug": 0, "AuthON": 1, "Authreq": 1, "Enable sys": 0, "Enable user": 0, "Max curr": 0, "Max curr %": 1000, "Curr HW": 0, "Curr user": 63000, "Curr FS": 0, "Tmo FS": 0, "Curr timer": 0, "Tmo CT": 0, "Setenergy": 0, "Output": 1, "Input": 0, "X2 phaseSwitch source": 4, "X2 phaseSwitch": 1, "Serial": "26663654", "Sec": 710443 } " 2025-02-09 15:06:51.424 - debug: kecontact.0 (17578) Sent "report 3" to 10.1.4.9:7090 2025-02-09 15:06:51.426 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "3", "U1": 0, "U2": 0, "U3": 0, "I1": 0, "I2": 0, "I3": 0, "P": 0, "PF": 0, "E pres": 17963, "E total": 56287936, "Serial": "26663654", "Sec": 710443 } " 2025-02-09 15:06:51.529 - debug: kecontact.0 (17578) Available max power: 23003.71 2025-02-09 15:06:51.529 - debug: kecontact.0 (17578) power: 23003.71 / voltage: 230 * 1000 / delta: 1000 / phases: 3 * delta = 33000 2025-02-09 15:06:51.529 - debug: kecontact.0 (17578) Available surplus: 4001.01 2025-02-09 15:06:51.725 - debug: kecontact.0 (17578) Sent "report 100" to 10.1.4.9:7090 2025-02-09 15:06:51.727 - debug: kecontact.0 (17578) UDP datagram from 10.1.4.9:7090: "{ "ID": "100", "Session ID": 358, "Curr HW": 32000, "E start": 56269973, "E pres": 17963, "started[s]": 1739107387, "ended[s]": 1739108862, "started": "2025-02-09 13:23:07.000", "ended": "2025-02-09 13:47:42.000", "reason": 4, "timeQ": 3, "RFID tag": "04420f8a5d6f8000", "RFID class": "9fc6e06a000000000000", "Serial": "26663654", "Sec": 710443 } " 2025-02-09 15:06:51.727 - debug: kecontact.0 (17578) History ID received: 00