Hallo Bluefox,
ich wende mich mal direkt an Dich. Als ich mich jetzt mal wieder mit dem Problem befasst habe habe ich mal wieder im hm-rpc-Adapter "Synchronisiere Geräte neu" angehakt. Danach sind mir im Log folgende Einträge aufgefallen:
`2016-07-26 16:29:05.258 - [33mwarn[39m: hm-rpc.0 Send this info to developer: {"type":"meta","meta":{"adapter":"hm-rpc","type":"paramsetDescription"},"common":{},"native":""}
2016-07-26 16:29:05.289 - [34mdebug[39m: hm-rpc.0 getValueParamsets HM-LC-Sw4-Ba-PCB.MAINTENANCE.3
2016-07-26 16:29:05.289 - [32minfo[39m: hm-rpc.0 xmlrpc -> getParamsetDescription ["LEQ0411469:0","VALUES"]
2016-07-26 16:29:05.289 - [33mwarn[39m: hm-rpc.0 xmlrpc <- undefined method getParamsetDescription ["LEQ0411469:0","VALUES"]
2016-07-26 16:29:05.305 - [32minfo[39m: hm-rpc.0 Send this info to developer: setObject hm-rpc.meta.VALUES.HM-LC-Sw4-Ba-PCB.MAINTENANCE.3
2016-07-26 16:29:05.305 - [33mwarn[39m: hm-rpc.0 Send this info to developer: {"type":"meta","meta":{"adapter":"hm-rpc","type":"paramsetDescription"},"common":{},"native":""}
2016-07-26 16:29:05.336 - [34mdebug[39m: hm-rpc.0 getValueParamsets HM-LC-Sw4-Ba-PCB.SWITCH.3
2016-07-26 16:29:05.336 - [32minfo[39m: hm-rpc.0 xmlrpc -> getParamsetDescription ["LEQ0411469:1","VALUES"]
2016-07-26 16:29:05.336 - [33mwarn[39m: hm-rpc.0 xmlrpc <- undefined method getParamsetDescription ["LEQ0411469:1","VALUES"]
2016-07-26 16:29:05.352 - [32minfo[39m: hm-rpc.0 Send this info to developer: setObject hm-rpc.meta.VALUES.HM-LC-Sw4-Ba-PCB.SWITCH.3
2016-07-26 16:29:05.352 - [33mwarn[39m: hm-rpc.0 Send this info to developer: {"type":"meta","meta":{"adapter":"hm-rpc","type":"paramsetDescription"},"common":{},"native":""}
2016-07-26 16:29:05.367 - [34mdebug[39m: hm-rpc.0 getValueParamsets HM-LC-Sw4-Ba-PCB.SWITCH.3
2016-07-26 16:29:05.383 - [32minfo[39m: hm-rpc.0 xmlrpc -> getParamsetDescription ["LEQ0411469:2","VALUES"]
2016-07-26 16:29:05.383 - [33mwarn[39m: hm-rpc.0 xmlrpc <- undefined method getParamsetDescription ["LEQ0411469:2","VALUES"]
2016-07-26 16:29:05.383 - [32minfo[39m: hm-rpc.0 Send this info to developer: setObject hm-rpc.meta.VALUES.HM-LC-Sw4-Ba-PCB.SWITCH.3
2016-07-26 16:29:05.399 - [33mwarn[39m: hm-rpc.0 Send this info to developer: {"type":"meta","meta":{"adapter":"hm-rpc","type":"paramsetDescription"},"common":{},"native":""}
2016-07-26 16:29:05.414 - [34mdebug[39m: hm-rpc.0 getValueParamsets HM-LC-Sw4-Ba-PCB.SWITCH.3
2016-07-26 16:29:05.430 - [32minfo[39m: hm-rpc.0 xmlrpc -> getParamsetDescription ["LEQ0411469:3","VALUES"]
2016-07-26 16:29:05.430 - [33mwarn[39m: hm-rpc.0 xmlrpc <- undefined method getParamsetDescription ["LEQ0411469:3","VALUES"]
2016-07-26 16:29:05.430 - [32minfo[39m: hm-rpc.0 Send this info to developer: setObject hm-rpc.meta.VALUES.HM-LC-Sw4-Ba-PCB.SWITCH.3
2016-07-26 16:29:05.430 - [33mwarn[39m: hm-rpc.0 Send this info to developer: {"type":"meta","meta":{"adapter":"hm-rpc","type":"paramsetDescription"},"common":{},"native":""}
2016-07-26 16:29:05.461 - [34mdebug[39m: hm-rpc.0 getValueParamsets HM-LC-Sw4-Ba-PCB.SWITCH.3
2016-07-26 16:29:05.477 - [32minfo[39m: hm-rpc.0 xmlrpc -> getParamsetDescription ["LEQ0411469:4","VALUES"]
2016-07-26 16:29:05.477 - [33mwarn[39m: hm-rpc.0 xmlrpc <- undefined method getParamsetDescription ["LEQ0411469:4","VALUES"]
2016-07-26 16:29:05.477 - [32minfo[39m: hm-rpc.0 Send this info to developer: setObject hm-rpc.meta.VALUES.HM-LC-Sw4-Ba-PCB.SWITCH.3 [/code]`
Ich habe die gleichartige Meldung noch für einige anderen Geräte - "zufälligerweise" betrifft das auch genau diese Geräte deren DP unvollständig angelegt werden!
Da ich diese Meldung "to developer" senden soll mache ich das hiermit ;) Was kann ich noch dazu tun? Liegt das Problem evtl. auf BidCos-Seite?