    M-TEC Energy Butler

    This topic has been deleted. Only users with topic management privileges can see it.
    • Homoran
      Homoran Global Moderator Administrators @metaxa last edited by

      @metaxa wrong crc hab ich noch nie gehabt
      A/B richtig rum?

      metaxa 1 Reply Last reply Reply Quote 0
      • metaxa
        metaxa @Homoran last edited by metaxa

        @homoran sagte in M-TEC Energy Butler:

        A/B richtig rum?

        Wie gesagt, mein Elektriker hat das gemacht. Aber ich springe mal in den Keller und tausche A/B um.

        @homoran sagte in M-TEC Energy Butler:

        hast du den Waveshare?

        Ja, den von dir empfohlenen (habe ihn auf 5V geschalten seitlich).

        Homoran 1 Reply Last reply Reply Quote 0
        • Homoran
          Homoran Global Moderator Administrators @metaxa last edited by

          @metaxa sagte in M-TEC Energy Butler:

          , den von dir empfohlenen

          da hatcder Elektriker auch angeklemmt?

          metaxa 1 Reply Last reply Reply Quote 0
          • metaxa
            metaxa @Homoran last edited by metaxa

            @homoran sagte in M-TEC Energy Butler:

            da hatcder Elektriker auch angeklemmt?

            Ja, aber nur am Stecker

            Könnte diese Einstellung auch falsch sein?
            8fd95f17-a19e-4f8e-aa5b-f6dd103c89dd-image.png

            Ich gehe jetzt einmal umklemmen 🙂

            Homoran metaxa 2 Replies Last reply Reply Quote 0
            • Homoran
              Homoran Global Moderator Administrators @metaxa last edited by

              @metaxa sagte in M-TEC Energy Butler:

              Könnte diese Einstellung auch falsch sein?

              ja, aber die hätte ich auch genommen.

              Ab jetzt fische ich auch im trüben und würde in den allgemeinen Parametern spielen.

              Alias mal aus -> was dann?
              und auch die anderen Checkboxen mal testen

              1 Reply Last reply Reply Quote 0
              • metaxa
                metaxa @metaxa last edited by metaxa

                @metaxa sagte in M-TEC Energy Butler:

                Ich gehe jetzt einmal umklemmen

                Uiiiiiii ..... das sind mehr Fehler als vorher

                
                modbus.0
                2023-06-23 21:59:39.687	info	Disconnected from slave
                
                modbus.0
                2023-06-23 21:59:39.583	error	Wrong CRC for frame: 255,1,2,2,52,252,255
                
                modbus.0
                2023-06-23 21:59:39.567	error	unknown function code: 0x0, 0x4
                
                modbus.0
                2023-06-23 21:59:39.552	error	unknown function code: 0x7e, 0xb5
                
                modbus.0
                2023-06-23 21:59:39.500	error	Error response: ff
                
                modbus.0
                2023-06-23 21:59:39.491	error	Error response: fd
                
                modbus.0
                2023-06-23 21:59:39.470	error	unknown function code: 0x7e, 0xdb
                
                modbus.0
                2023-06-23 21:59:39.441	error	unknown function code: 0x7e, 0x5e
                
                modbus.0
                2023-06-23 21:59:39.393	error	Error response: e2
                
                modbus.0
                2023-06-23 21:59:39.381	error	Error response: ff
                
                modbus.0
                2023-06-23 21:59:39.366	error	Error response: ff
                
                modbus.0
                2023-06-23 21:59:39.348	error	Error response: ff
                
                modbus.0
                2023-06-23 21:59:39.336	error	Error response: f9
                
                modbus.0
                2023-06-23 21:59:39.318	error	Error response: ff
                
                modbus.0
                2023-06-23 21:59:39.302	error	unknown function code: 0x65, 0xff
                
                modbus.0
                2023-06-23 21:59:39.297	error	Error response: ff
                
                modbus.0
                2023-06-23 21:59:39.282	error	Error response: af
                
                modbus.0
                2023-06-23 21:59:39.277	error	Error response: fe
                
                modbus.0
                2023-06-23 21:59:39.259	error	unknown function code: 0x0, 0x4
                
                modbus.0
                2023-06-23 21:59:39.242	error	unknown function code: 0x0, 0x4
                
                modbus.0
                2023-06-23 21:59:39.182	error	Error response: ff
                
                modbus.0
                2023-06-23 21:59:39.174	error	Error response: a9
                
                modbus.0
                2023-06-23 21:59:39.158	error	Error response: ff
                
                modbus.0
                2023-06-23 21:59:39.144	error	Error response: ff
                
                modbus.0
                2023-06-23 21:59:39.129	error	Error response: fd
                
                modbus.0
                2023-06-23 21:59:39.110	error	Error response: ff
                
                modbus.0
                2023-06-23 21:59:39.093	error	Error response: eb
                
                modbus.0
                2023-06-23 21:59:39.075	error	Wrong CRC for frame: 0,4,126,181,131,239,13,58,0,4,126,247,255,255,255,1,2,2,140,252,255,255,241,255,255,255,255,3,93,0,4,126,108,247,233,201,43,0,4,126,186,169,103,103,179,102,246,182,246,246,44,150,246,182,54,214,54,110,255,255,255,255,131,154,0,4,126,108,67,221,107,133,0,4,126,183,251,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,81,94,0,4,126,181,128,135,143,181,0,4,126,232,183,251,151,247,151,107,97,255
                
                modbus.0
                2023-06-23 21:59:38.686	warn	Poll error count: 1 code: {"err":"timeout","timeout":5000}
                
                modbus.0
                2023-06-23 21:59:38.685	error	Request timed out.
                
                modbus.0
                2023-06-23 21:59:38.684	warn	Error: undefined
                
                modbus.0
                2023-06-23 21:59:36.679	error	Error response: e7
                
                modbus.0
                2023-06-23 21:59:36.664	error	Error response: fb
                
                modbus.0
                2023-06-23 21:59:36.657	error	Error response: fb
                
                modbus.0
                2023-06-23 21:59:36.641	error	unknown function code: 0x7e, 0xdb
                
                modbus.0
                2023-06-23 21:59:36.626	error	unknown function code: 0x7e, 0x5e
                
                modbus.0
                2023-06-23 21:59:36.570	error	Error response: 52
                
                modbus.0
                2023-06-23 21:59:36.564	error	Error response: ff
                
                modbus.0
                2023-06-23 21:59:36.548	error	Error response: ff
                
                modbus.0
                2023-06-23 21:59:36.532	error	Error response: ff
                
                modbus.0
                2023-06-23 21:59:36.523	error	Error response: f9
                
                modbus.0
                2023-06-23 21:59:36.504	error	Error response: ff
                
                modbus.0
                2023-06-23 21:59:36.489	error	unknown function code: 0x65, 0xff
                
                modbus.0
                2023-06-23 21:59:36.483	error	Error response: ff
                
                modbus.0
                2023-06-23 21:59:36.467	error	unknown function code: 0x79, 0xff
                
                modbus.0
                2023-06-23 21:59:36.462	error	Error response: f3
                
                modbus.0
                2023-06-23 21:59:36.444	error	unknown function code: 0x0, 0x4
                
                modbus.0
                2023-06-23 21:59:36.428	error	Wrong CRC for frame: 0,4,126,232,247,251,183,247,151,107,103,255,237,237,103,255,183,237,91,255,235,217,243,254,255,249,241,254,255,253,179,255,255,253,249,254,255,255,193,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,253,157,250,129,250,187,250,129,134,115,225,185,255,255,255,253,255,255,255,253,99,191,101,49,198,129,255,255,173,137,254,255,255,251,91,117,225,1,254,225,253,253,255,127,195,169,134,169,174,111,159,143,235,239,173,247,253,253,255,255,255,255,255,255,255,255,255,255,37,154,0,4,126,69,224,135
                
                modbus.0
                2023-06-23 21:59:36.230	error	Wrong CRC for frame: 0,4,126,108,247,233,201,43,0,4,126,186,169,103,103,179,102,246,182,246,246,44,150,246,182,54,214,54,110,255,255,255,255,131,154,0,4,126,108,67,221,107,133,0,4,126,183,251,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,81,94,0,4,126,108,67,221,107,133,0,4,126,183,251,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,81,94,0,4
                
                modbus.0
                2023-06-23 21:59:33.671	debug	[DevID_247/inputRegs] Poll address 2999 - 1 registers
                
                modbus.0
                2023-06-23 21:59:33.670	debug	Initialization of scale factors done!
                
                modbus.0
                2023-06-23 21:59:33.667	debug	[DevID_247] Poll start ---------------------
                
                modbus.0
                2023-06-23 21:59:33.665	info	Connected to slave
                
                modbus.0
                2023-06-23 21:59:33.636	debug	connect to serial /dev/ttyUSB1 with 9600
                
                modbus.0
                2023-06-23 21:59:32.476	debug	Initialize Objects for holdingRegs: []
                
                modbus.0
                2023-06-23 21:59:32.473	debug	Add inputRegisters.33000_State_of_Charge_(SOC): {"_id":"inputRegisters.33000_State_of_Charge_(SOC)","type":"state","common":{"name":"Ladezustand der Batterie","role":"level","type":"number","read":true,"write":false,"def":0,"unit":"%"},"native":{"regType":"inputRegs","address":2999,"deviceId":247,"type":"uint16be","len":1,"offset":0,"factor":1}}
                
                modbus.0
                2023-06-23 21:59:32.469	debug	Initialize Objects for inputRegs: [{"_address":"33000","name":"State of Charge (SOC)","description":"Ladezustand der Batterie","unit":"%","type":"uint16be","len":1,"factor":1,"offset":0,"formula":"","role":"level","room":"","cw":"","isScale":"","address":2999,"deviceId":247,"id":"inputRegisters.33000_State_of_Charge_(SOC)"}]
                
                modbus.0
                2023-06-23 21:59:32.461	debug	Initialize Objects for coils: []
                
                modbus.0
                2023-06-23 21:59:32.458	debug	Initialize Objects for disInputs: []
                
                modbus.0
                2023-06-23 21:59:31.818	info	starting. Version 5.0.11 in /opt/iobroker/node_modules/iobroker.modbus, node: v16.19.1, js-controller: 4.0.24
                

                Klemme wieder zurück!

                Homoran 1 Reply Last reply Reply Quote 0
                • Homoran
                  Homoran Global Moderator Administrators @metaxa last edited by

                  @metaxa sagte in M-TEC Energy Butler:

                  Klemme wieder zurück!

                  ja! wie blinkt es denn?

                  metaxa 1 Reply Last reply Reply Quote 0
                  • metaxa
                    metaxa @Homoran last edited by metaxa

                    @homoran sagte in M-TEC Energy Butler:

                    wie blinkt es denn?

                    Kurz nur die rechte LED flackert nach dem Bestromen blau hört aber nach 2 Sekunden wieder auf und bleibt finster, links Power bleibt brav rot.

                    Homoran 1 Reply Last reply Reply Quote 0
                    • Homoran
                      Homoran Global Moderator Administrators @metaxa last edited by Homoran

                      @metaxa der müsste jede Sekunde Blinken.
                      Brauchst du so viele Daten? sonst setz das Intervall runter 5000msec müssten vollkommen reichen.

                      metaxa 1 Reply Last reply Reply Quote 0
                      • metaxa
                        metaxa @Homoran last edited by metaxa

                        @homoran
                        Habe jetzt wieder zurückgeklemmt, paar von diesen 16Bit Einträgen ausprobiert, es kommt immer dieser "Wrong SRC for frame"

                        modbus.0
                        2023-06-23 22:16:39.630	debug	[DevID_247] Poll start ---------------------
                        
                        modbus.0
                        2023-06-23 22:16:37.896	error	Wrong CRC for frame: 247,3,117,248,0,60,202,176,247,3,120,9,71,0,3,19,134,0,0,0,0,0,41,0,0,0,0,0,0,0,0,9,64,0,38,19,136,0,0,0,0,2,161,0,0,0,0,0,0,0,0,9,74,0,3,19,138,0,0,0,0,0,28,0,0,0,0,0,0,0,0,0,0,2,230,0,0,0,0,0,0,0,0,0,0,0,83,0,0,0,0,0,0,0,0,0,0,2,173,0,0,0,0,0,0,0,0,0,0,0,83,0,0,0,0,0,0,0,0,9,27,0
                        
                        modbus.0
                        2023-06-23 22:16:37.561	error	Error response: 28
                        
                        modbus.0
                        2023-06-23 22:16:37.497	error	unknown function code: 0x0, 0x0
                        
                        modbus.0
                        2023-06-23 22:16:37.486	error	Wrong CRC for frame: 247,3,128,232,0,18,120,165,247,3,36,19,92,39,15,0,2,0,244,255,255,255,255,255,255,255,255,0,0,1,1,0,0,0,230,0,0,12,195,0,0,12,183,0,0,0,0,226,200,247,3,42,242,0,8,249,113,247,3,16,0,0,0,0,255,255,255,243,0,0,0,7,0,0,0,0,235,1,247,3,39,16,0,11,27,234,247,3,22,90,49,49,50,51,48,48,50,48,56,51,51,48,50,54,49,30,6,0,0,0,0,190,217,247,3,39,121,0,17,74,61,247,3,34,0,2,0,0,0,0,0,0,0
                        
                        modbus.0
                        2023-06-23 22:16:35.088	error	Wrong CRC for frame: 247,3,117,248,0,60,202,176,247,3,120,9,67,0,5,19,134,0,0,0,0,0,42,0,0,0,0,0,0,0,0,9,67,0,36,19,134,0,0,0,0,2,166,0,0,0,0,0,0,0,0,9,74,0,3,19,138,0,0,0,0,0,27,0,0,0,0,0,0,0,0,0,0,2,235,0,0,0,0,0,0,0,0,0,0,0,83,0,0,0,0,0,0,0,0,0,0,2,184,0,0,0,0,0,0,0,0,0,0,0,85,0,0,0,0,0,0,0,0,9,28,0
                        
                        modbus.0
                        2023-06-23 22:16:34.750	error	unknown function code: 0x28, 0xf7
                        
                        modbus.0
                        2023-06-23 22:16:34.687	error	Wrong CRC for frame: 247,3,39,121,0,17,74,61,247,3,34,0,2,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0
                        
                        modbus.0
                        2023-06-23 22:16:34.589	error	unknown function code: 0x0, 0x0
                        
                        modbus.0
                        2023-06-23 22:16:34.574	error	Wrong CRC for frame: 247,3,42,242,0,8,249,113,247,3,16,0,0,0,0,0,0,0,13,0,0,0,7,0,0,0,26,115,95,247,3,39,16,0,11,27,234,247,3,22,90,49,49,50,51,48,48
                        
                        modbus.0
                        2023-06-23 22:16:32.338	error	Error response: Value is not accepted by slave
                        
                        modbus.0
                        2023-06-23 22:16:32.337	error	Error response for FCx119: Illegal Data Value
                        
                        modbus.0
                        2023-06-23 22:16:32.275	error	Wrong CRC for frame: 247,3,117,248,0,60,202,176,247,3,120,9,69,0,5,19,134,0,0,0,0,0,42,0,0,0,0,0,0,0,0,9,62,0,35,19,134,0,0,0,0,2,162,0,0,0,0,0,0,0,0,9,76,0,2,19,134,0,0,0,0,0,27,0,0,0,0,0,0,0,0,0,0,2,231,0,0,0,0,0,0,0,0,0,0,0,84,0,0,0,0,0,0,0,0,0,0,2,237,0,0,0,0,0,0,0,0,0,0,0,85,0,0,0,0,0,0,0,0,9,28,0
                        
                        modbus.0
                        2023-06-23 22:16:31.940	error	Error response: 28
                        
                        modbus.0
                        2023-06-23 22:16:31.879	error	unknown function code: 0x0, 0x0
                        
                        modbus.0
                        2023-06-23 22:16:31.861	error	unknown function code: 0x0, 0x0
                        
                        modbus.0
                        2023-06-23 22:16:31.843	error	unknown function code: 0x3d, 0xf7
                        
                        modbus.0
                        2023-06-23 22:16:31.835	error	unknown function code: 0x0, 0xbe
                        
                        modbus.0
                        2023-06-23 22:16:31.766	error	Wrong CRC for frame: 247,3,42,242,0,8,249,113,247,3,16,0,0,0,0,0,0,0,20,0,0,0,7,0,0,0,33,149,28,247,3,39,16,0,11,27,234,247,3,22,90,49,49,50,51,48,48
                        
                        modbus.0
                        2023-06-23 22:16:29.577	warn	Poll error count: 1 code: "ReadInputRegisters: Invalid FC 3"
                        
                        modbus.0
                        2023-06-23 22:16:29.527	error	Error response: f7
                        
                        modbus.0
                        2023-06-23 22:16:29.468	error	unknown function code: 0x0, 0x0
                        
                        modbus.0
                        2023-06-23 22:16:29.447	error	unknown function code: 0x0, 0x0
                        
                        modbus.0
                        2023-06-23 22:16:29.432	error	unknown function code: 0x53, 0x0
                        
                        modbus.0
                        2023-06-23 22:16:29.416	error	unknown function code: 0x0, 0x0
                        
                        modbus.0
                        2023-06-23 22:16:29.400	error	unknown function code: 0x13, 0x86
                        
                        modbus.0
                        2023-06-23 22:16:29.384	error	unknown function code: 0x0, 0x2
                        
                        modbus.0
                        2023-06-23 22:16:29.371	error	Wrong CRC for frame: 0,3,247,3,39,16,0,11,27,234,247,3,22,90,49,49,50,51,48,48,50,48,56,51,51,48,50,54,49,30,6,0,0,0,0,190,217,247,3,39,121,0,17,74,61,247,3,34,0,2,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,215,40,247,3,42,254,0,60,56,165,247,3,120,16,25,16,24,16,29,9,73,0,9,9,76,0,32,9,77,0,10,19,135,0,0,3,1,0,0,1,41,0,0,1,134,0,0,0,31,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,1,176,1,190,1,161,1,190,30,63,15,30,0,0,0,1,0,0,0,1,78,32,78,6,78,45,0,0,41,187,0,0,0,2,81,199,15,255,0,15,1,1,0,64,30,163,30,163,19,93,48,56,10,8,41,4,1,1,0,0,0,0,0,0,0,0,0,0,245,199,247,3,117,248,0,60,202,176,247,3,120,9,68,0,5,19,134,0,0,0,0,0,42,0,0,0,0,0,0,0,0,9,66,0,37
                        
                        modbus.0
                        2023-06-23 22:16:28.445	debug	[DevID_247/inputRegs] Poll address 2999 - 1 registers
                        
                        modbus.0
                        2023-06-23 22:16:28.444	debug	Initialization of scale factors done!
                        
                        modbus.0
                        2023-06-23 22:16:28.440	debug	[DevID_247] Poll start ---------------------
                        
                        modbus.0
                        2023-06-23 22:16:28.438	info	Connected to slave
                        
                        modbus.0
                        2023-06-23 22:16:28.415	debug	connect to serial /dev/ttyUSB1 with 9600
                        
                        modbus.0
                        2023-06-23 22:16:27.710	debug	Initialize Objects for holdingRegs: []
                        
                        modbus.0
                        2023-06-23 22:16:27.709	debug	Add inputRegisters.2999_State_of_Charge_(SOC): {"_id":"inputRegisters.2999_State_of_Charge_(SOC)","type":"state","common":{"name":"Ladezustand der Batterie","role":"level","type":"number","read":true,"write":false,"def":0,"unit":"%"},"native":{"regType":"inputRegs","address":2999,"deviceId":247,"type":"int16le","len":1,"offset":0,"factor":1}}
                        
                        modbus.0
                        2023-06-23 22:16:27.708	debug	Initialize Objects for inputRegs: [{"_address":2999,"name":"State of Charge (SOC)","description":"Ladezustand der Batterie","unit":"%","type":"int16le","len":1,"factor":1,"offset":0,"formula":"","role":"level","room":"","cw":false,"isScale":"","address":2999,"deviceId":247,"id":"inputRegisters.2999_State_of_Charge_(SOC)"}]
                        
                        modbus.0
                        2023-06-23 22:16:27.707	debug	Initialize Objects for coils: []
                        
                        modbus.0
                        2023-06-23 22:16:27.706	debug	Initialize Objects for disInputs: []
                        
                        modbus.0
                        2023-06-23 22:16:27.222	info	starting. Version 5.0.11 in /opt/iobroker/node_modules/iobroker.modbus, node: v16.19.1, js-controller: 4.0.24
                        

                        alais Checkbox hat nix verändert.

                        metaxa 1 Reply Last reply Reply Quote 0
                        • metaxa
                          metaxa @metaxa last edited by

                          Kann ich aus dem LOG erkennen ob da am anderen Ende überhaupt Daten sind, die Busschnittstelle die richtige ist?

                          Homoran 1 Reply Last reply Reply Quote 0
                          • Homoran
                            Homoran Global Moderator Administrators @metaxa last edited by

                            @metaxa das versuche ich die ganze Zeit zu erkennen.
                            was sagt denn lsusb?

                            metaxa 1 Reply Last reply Reply Quote 0
                            • metaxa
                              metaxa @Homoran last edited by

                              @homoran sagte in M-TEC Energy Butler:

                              lsusb

                              andreas@iOProduktiv:~$ lsusb -t
                              /:  Bus 07.Port 1: Dev 1, Class=root_hub, Driver=uhci_hcd/2p, 12M
                              /:  Bus 06.Port 1: Dev 1, Class=root_hub, Driver=uhci_hcd/2p, 12M
                              /:  Bus 05.Port 1: Dev 1, Class=root_hub, Driver=xhci_hcd/4p, 5000M
                              /:  Bus 04.Port 1: Dev 1, Class=root_hub, Driver=uhci_hcd/2p, 12M
                                  |__ Port 1: Dev 2, If 0, Class=Vendor Specific Class, Driver=ch341, 12M
                                  |__ Port 2: Dev 5, If 0, Class=Vendor Specific Class, Driver=ftdi_sio, 12M
                              /:  Bus 03.Port 1: Dev 1, Class=root_hub, Driver=xhci_hcd/4p, 480M
                                  |__ Port 1: Dev 2, If 0, Class=Human Interface Device, Driver=usbfs, 12M
                              /:  Bus 02.Port 1: Dev 1, Class=root_hub, Driver=uhci_hcd/2p, 12M
                                  |__ Port 1: Dev 2, If 0, Class=Human Interface Device, Driver=usbhid, 12M
                              /:  Bus 01.Port 1: Dev 1, Class=root_hub, Driver=ehci-pci/6p, 480M
                              
                              
                              andreas@iOProduktiv:~$ ls -l /dev/serial/by-id
                              insgesamt 0
                              lrwxrwxrwx 1 root root 13 23. Jun 19:53 usb-1a86_USB_Serial-if00-port0 -> ../../ttyUSB0
                              lrwxrwxrwx 1 root root 13 23. Jun 22:09 usb-FTDI_FT232R_USB_UART_A10N5R2A-if00-port0 -> ../../ttyUSB1
                              andreas@iOProduktiv:~$
                              
                              Homoran 1 Reply Last reply Reply Quote 0
                              • Homoran
                                Homoran Global Moderator Administrators @metaxa last edited by Homoran

                                @metaxa was hängt denn noch dran?

                                pi@tinkerboard:~$ ls -l /dev/serial/by-id
                                insgesamt 0
                                lrwxrwxrwx 1 root root 13 14. Mai 22:54 usb-FTDI_FT232R_USB_UART_A10NBMVW-if00-port0 -> ../../ttyUSB1
                                lrwxrwxrwx 1 root root 13 14. Mai 22:53 usb-FTDI_FT232R_USB_UART_AB0OH9QR-if00-port0 -> ../../ttyUSB2
                                lrwxrwxrwx 1 root root 13 14. Mai 22:53 usb-Silicon_Labs_CP2104_USB_to_UART_Bridge_Controller_01066523-if00-port0 -> ../../ttyUSB0
                                

                                ich hab 2 dran

                                metaxa 1 Reply Last reply Reply Quote 0
                                • metaxa
                                  metaxa @Homoran last edited by metaxa

                                  @homoran
                                  NUC -->
                                  1x USB für NUT (APC)
                                  1x USB Hub (Hama)
                                  --> ZigbeeStick
                                  --> Waveshare
                                  393ebd07-4043-4b47-bd9d-c46ac5236c8f-image.png

                                  Homoran 1 Reply Last reply Reply Quote 0
                                  • Homoran
                                    Homoran Global Moderator Administrators @metaxa last edited by

                                    @metaxa dann bist du mit usb1 wohl richtig

                                    metaxa 1 Reply Last reply Reply Quote 0
                                    • metaxa
                                      metaxa @Homoran last edited by metaxa

                                      @homoran 479a3a48-29fa-4baf-82e7-1978bcc54e07-image.png

                                      Ich stehe momentan an, habe keine Idee zur Zeit.

                                      Aber großen Dank zum 100sten Mal für deine Zeit und deine Geduld.

                                      mxa

                                      Homoran 1 Reply Last reply Reply Quote 0
                                      • Homoran
                                        Homoran Global Moderator Administrators @metaxa last edited by Homoran

                                        @metaxa Geduld hilft dir nicht wirklich.

                                        Hab keine Ahnung wo so ein Checksummenfehler herkommt und was man tun kann.
                                        ganz tief im Bauch meint jemsnd dass da was in die Leitungen einstreut.

                                        Aber glaub ich ehrlich nicht

                                        Dann erst mal gute Nacht

                                        metaxa Homoran 2 Replies Last reply Reply Quote 1
                                        • metaxa
                                          metaxa @Homoran last edited by

                                          @Homoran
                                          Gute Nacht und nochmals Danke! Eventuell findet sich ja noch ein weiterer Modbus - System -Guru und erbarmt sich 🙂

                                          1 Reply Last reply Reply Quote 0
                                          • metaxa
                                            metaxa @manrum1 last edited by

                                            @manrum1 sagte in M-TEC Energy Butler:

                                            Aber sicher werde ich danach die Anlage anbinden.

                                            Was wurde denn alles bei dir an M-TEC Gerätschaften verbaut?

                                            Bei mir

                                            • Butler BMS
                                            • 3x Energy Butler Batteriemodul 3,84 kWh
                                            • E-Smart T4 (Vorsicht!)
                                            M 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            577
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            21
                                            201
                                            29671
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo