    • Homoran
      Homoran Global Moderator Administrators @metaxa last edited by

      @metaxa aah!
      nix modbus!

      EMS Bus Wi-Fi Gateway

      1 Reply Last reply Reply Quote 0
      • metaxa
        metaxa @Homoran last edited by metaxa

        @homoran sagte in M-TEC Energy Butler:

        und als Antwort
        @metaxa sagte in M-TEC Energy Butler:

        Wrong CRC for frame: 247,3,39,16,0,11,27,234,247,3,22,90,49,49,50,51,48,48,50,48,56,51,51,48,50,54,49,30,6,0,0,0,0,190,217,247,3,39,121,0,17,74,61,247

        Du hast vollkommen recht! Ich habe jetzt den Stecker mit den BUS Kabeln vom Converter gezogen und den Adapter nochmals gestartet. Jetzt bekomme ich als Antwort keinen CRC Fehler sondern das hier:

        modbus.0
        2023-06-24 21:11:37.197	info	Disconnected from slave
        
        modbus.0
        2023-06-24 21:11:36.196	warn	Poll error count: 1 code: {"err":"timeout","timeout":5000}
        
        modbus.0
        2023-06-24 21:11:36.194	error	Request timed out.
        
        modbus.0
        2023-06-24 21:11:36.192	warn	Error: undefined
        
        modbus.0
        2023-06-24 21:11:31.173	debug	[DevID_247/inputRegs] Poll address 33000 - 1 registers
        
        modbus.0
        2023-06-24 21:11:31.171	debug	Initialization of scale factors done!
        
        modbus.0
        2023-06-24 21:11:31.167	debug	[DevID_247] Poll start ---------------------
        
        modbus.0
        2023-06-24 21:11:31.163	info	Connected to slave
        

        Wenn jetzt noch jemand all meine Settings im Adapter als gut bestätigt kann ich bei der Montagefirma aufmagaziniert anklopfen 🙂 Wäre nämlich blöd wenn bei den einzelnen Parametern iwas falsch ist.

        Wer ist bei meinem PV-Modbus MASTER und wer Slave? Ist ioB Slave?

        Homoran 1 Reply Last reply Reply Quote 0
        • Homoran
          Homoran Global Moderator Administrators @metaxa last edited by

          @metaxa sagte in M-TEC Energy Butler:

          sondern das hier:

          passt ja!
          es kommt keine Antwort mehr, der poll läuft in den Timeout.

          @metaxa sagte in M-TEC Energy Butler:

          Wenn jetzt noch jemand all meine Settings im Adapter als gut bestätigt

          ich kann das leider nicht, sorry!

          @metaxa sagte in M-TEC Energy Butler:

          Wer ist bei meinem PV-Modbus MASTER und wer Slave? Ist ioB Slave?

          bei RTU kann ich da nichts einstellen.

          metaxa 1 Reply Last reply Reply Quote 1
          • metaxa
            metaxa @Homoran last edited by

            @homoran sagte in M-TEC Energy Butler:

            Wer ist bei meinem PV-Modbus MASTER und wer Slave? Ist ioB Slave?

            Ich denke, für das Erste sind wir am Ende dieses Ausflugs und herzlichst bedanke mich für deine Ideen, deine Geduld und dein Querdenken.

            Bischt a topmod und immer für die TN da!
            Grüße aus Wien, mxa

            1 Reply Last reply Reply Quote 0
            • M
              manrum1 @metaxa last edited by

              @metaxa said in M-TEC Energy Butler:

              Butler BMS
              3x Energy Butler Batteriemodul 3,84 kWh

              bei mir habe ich nur die Standard-Konfiguration:

              • Butler BMS
              • 3x Energy Butler Batteriemodul 3,84 kWh

              Warum E-Smart T4 und "Vorsicht"?

              metaxa 1 Reply Last reply Reply Quote 0
              • wendy2702
                wendy2702 last edited by

                Da mein Name gefallen ist.

                Wird noch Hilfe benötigt oder läuft es jetzt?

                Wurde mal ein anderes Modbus tool probiert bevor der Adapter verwendet wurde?

                Homoran 1 Reply Last reply Reply Quote 0
                • Homoran
                  Homoran Global Moderator Administrators @wendy2702 last edited by Homoran

                  @wendy2702 sagte in M-TEC Energy Butler:

                  Wird noch Hilfe benötigt

                  sehr wahrscheinlich!

                  @wendy2702 sagte in M-TEC Energy Butler:

                  läuft es jetzt?

                  nicht wirklich

                  @metaxa müsste den aktuellen Stand vermelden

                  metaxa 1 Reply Last reply Reply Quote 0
                  • metaxa
                    metaxa @Homoran last edited by metaxa

                    @wendy2702 sagte in M-TEC Energy Butler:

                    Hilfe benötigt

                    Bitte ja! Um 100% auszuschließen, dass der Fehler bei mir liegt.

                    @wendy2702 sagte in M-TEC Energy Butler:

                    anderes Modbus tool probiert

                    Nein. Diese Programme für WIN
                    6e9ec031-f309-42c1-871a-54458143b94f-image.png
                    habe ich im Netz gefunden, jedoch den Aufwand gescheut den Converter unter Windows10 einzubinden um nicht eine weitere Baustelle zu haben bei der ich kA habe was ich tue.

                    @homoran sagte in M-TEC Energy Butler:

                    aktuellen Stand

                    Ich habe Montag den Chef-Solateur informiert, dass ich keine Daten auslesen kann (CRC Fehler) Er schloß sich meiner Meinung an, dass der BUS für mein Kabelende eher nicht nach vorgesehenem Schema
                    d4c05cfd-b749-4ec9-9cd1-b3f394d7ac6d-image.png
                    verdrahtet wurde.

                    Sytemintern scheint die bestehende Verkabelung zu funktionieren, da es funktioniert.

                    Homoran 1 Reply Last reply Reply Quote 0
                    • Homoran
                      Homoran Global Moderator Administrators @metaxa last edited by

                      @metaxa sagte in M-TEC Energy Butler:

                      Er schloß sich meiner Meinung an, dass der BUS für mein Kabelende eher nicht nach vorgesehenem Schema

                      verdrahtet wurde.

                      dann sind wir ja schon drei mit dieser Meinung.
                      Da sehe ich mögliches Licht am Ende des Tunnels

                      1 Reply Last reply Reply Quote 1
                      • metaxa
                        metaxa @manrum1 last edited by

                        @manrum1 sagte in M-TEC Energy Butler:

                        Warum E-Smart T4 und "Vorsicht"?

                        Weil ich mir das Ding höchstwahrscheinlich unnötig angeschafft habe. Ich dachte bei der Beauftragung, dass ich das Ding unbedingt für einen künftigen Weiterausbau (WP, Heizstab, Wallbox) benötige. Was ich nicht wußte, dass man offensichtlich jede einzelne Funktion mit einem kostenpflichtigen Lizenzschlüssel freischalten muß. Aber im Detail habe ich mich damit noch nicht beschäftigt.

                        1 Reply Last reply Reply Quote 0
                        • G
                          gagafreeman last edited by gagafreeman

                          Servus zusammen,
                          bin auch ein Besitzer von Energy Butler 10kW-3P-3G25 und habe das ganze mal verfolgt.
                          Mit erfolg habe ich die Kommnikation zwischen dem Wechselrichter und Iobrocker hinbekommen,
                          habe den 2a88550a-a69b-42e3-b0cc-f3d645dc6344-grafik.png stecker nur A und B bei 13 und 14 angeschlossen die Abschlusswiderstände habe ich nicht deaktivert,
                          mein Converter ist der "Waveshare RS485 to RJ45 Ethernet Converter Module, Industrial Rail-Mount RS485 Serial Server,TCP/IP to Serial Module,300~115200 BPS Baudrate,10 / 100M Auto-Negotiation RJ45 Connector" nach lagen versuchen muss habe ich geschaft 😀 .

                          Folgen einstellung habe ich im IoBrocker 93dca4c6-1f5a-4cca-9679-45de64fffe8c-grafik.png und dan in die Holding Register

                          c586c64c-0d65-48d8-97bb-87d87866b9d6-grafik.png
                          und so siehts mal aus oben die erweiter ansicht aktiviren damit du den factor ein tragen kannst sonst sind es die Rohrwerte.

                          Das ergebins in den Objekten 74ab5dc7-4dc5-4e36-a1c0-66d01c36547b-grafik.png.

                          Als kleine hilfe habe ich diese Software benutz um die Komminaktion zu prüfen https://sourceforge.net/projects/qmodmaster/ unterstütz serial und auch TCP Verbindungen, ohne eine Installtion ein ausfürungs exe.

                          Die einstellungen im Waveshare fa9f2559-6d4f-4ef2-a99c-6b5eed75976f-grafik.png

                          hoffe du kannst es auch zum laufen kriegen.

                          metaxa - S M F 6 Replies Last reply Reply Quote 2
                          • metaxa
                            metaxa @gagafreeman last edited by metaxa

                            @gagafreeman sagte in M-TEC Energy Butler:

                            habe ich geschaft .

                            Mahhh, das ist ein positives Zeichen! Ich muss mir das in den nächsten Tagen ansehen, eventuell auch meinen Converter tauschen.

                            Edit: Converter ist bestellt 🙂

                            GANZ, lieben Dank für deine Meldung hier!

                            1 Reply Last reply Reply Quote 0
                            • -
                              -FX-RIDER- @gagafreeman last edited by

                              @gagafreeman Servus und Glückwunsch!
                              Mein Energy Butler läuft nun, daher wird es Zeit mich an das Modbus Thema zu machen.

                              Mein Plan war aber den Modbus am Smartmeter abzugreifen - da es direkt im Zählerschrank hängt und ich den Waveshare direkt daneben klemmen würde. 24V DC Versorgung habe ich dort auch, daher wäre das optimal.

                              Weißt du ob am Smartmeter ein Abschlusswiderstand verbaut / konfigurierbar ist? Bzw. hast Du, oder jmd. anders hier schon mal probiert es dort abzugreifen?

                              G M 2 Replies Last reply Reply Quote 0
                              • metaxa
                                metaxa @gagafreeman last edited by

                                @gagafreeman ist das deine IP von deinem iOBroker, oder wessen IP gehört da rein?
                                8d5bebd1-55b1-48b7-860c-37350aceeed5-image.png

                                G 1 Reply Last reply Reply Quote 0
                                • metaxa
                                  metaxa last edited by metaxa

                                  @gagafreeman Ich habe die IP dort unverändert stehen lassen und ES FUNKTIONIERT! Danke für Dein Posten der Einstellungen! Jedoch hagelt es mir LOG mit folgender Fehlermeldung voll:

                                  modbus.0
                                  2023-07-06 14:54:51.873	warn	Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  

                                  Ausfühliches LOG:

                                  2023-07-06 15:01:12.285 - debug: modbus.0 (1808930) Redis Objects: Use Redis connection: 0.0.0.0:9001
                                  2023-07-06 15:01:12.616 - debug: modbus.0 (1808930) Objects client ready ... initialize now
                                  2023-07-06 15:01:12.699 - debug: modbus.0 (1808930) Objects create System PubSub Client
                                  2023-07-06 15:01:12.715 - debug: modbus.0 (1808930) Objects create User PubSub Client
                                  2023-07-06 15:01:13.495 - debug: modbus.0 (1808930) Objects client initialize lua scripts
                                  2023-07-06 15:01:13.601 - debug: modbus.0 (1808930) Objects connected to redis: 0.0.0.0:9001
                                  2023-07-06 15:01:13.846 - debug: modbus.0 (1808930) Redis States: Use Redis connection: 0.0.0.0:9000
                                  2023-07-06 15:01:14.241 - debug: modbus.0 (1808930) States create System PubSub Client
                                  2023-07-06 15:01:14.243 - debug: modbus.0 (1808930) States create User PubSub Client
                                  2023-07-06 15:01:15.433 - debug: modbus.0 (1808930) States connected to redis: 0.0.0.0:9000
                                  2023-07-06 15:01:17.006 - debug: modbus.0 (1808930) Plugin sentry Initialize Plugin (enabled=true)
                                  2023-07-06 15:01:19.674 - info: modbus.0 (1808930) starting. Version 5.0.11 in /opt/iobroker/node_modules/iobroker.modbus, node: v16.19.1, js-controller: 4.0.24
                                  2023-07-06 15:01:20.724 - debug: modbus.0 (1808930) Initialize Objects for disInputs: []
                                  2023-07-06 15:01:20.727 - debug: modbus.0 (1808930) Initialize Objects for coils: []
                                  2023-07-06 15:01:20.729 - debug: modbus.0 (1808930) Initialize Objects for inputRegs: []
                                  2023-07-06 15:01:20.730 - debug: modbus.0 (1808930) Initialize Objects for holdingRegs: [{"_address":"33000","name":"State of Charge (SOC)","description":"Ladezustand der Batterie","unit":"%","type":"uint16be","len":1,"factor":0.01,"offset":4,"formula":"","role":"value","room":"","poll":true,"wp":"","cw":"","isScale":"","address":33000,"deviceId":247,"id":"holdingRegisters.33000_State_of_Charge_(SOC)"}]
                                  2023-07-06 15:01:20.731 - debug: modbus.0 (1808930) Add holdingRegisters.33000_State_of_Charge_(SOC): {"_id":"holdingRegisters.33000_State_of_Charge_(SOC)","type":"state","common":{"name":"Ladezustand der Batterie","role":"value","type":"number","read":true,"write":true,"def":0,"unit":"%"},"native":{"regType":"holdingRegs","address":33000,"deviceId":247,"type":"uint16be","len":1,"offset":4,"factor":0.01,"poll":true}}
                                  2023-07-06 15:01:21.969 - info: modbus.0 (1808930) Connected to slave 192.168.0.216
                                  2023-07-06 15:01:21.972 - debug: modbus.0 (1808930) [DevID_247] Poll start ---------------------
                                  2023-07-06 15:01:21.974 - debug: modbus.0 (1808930) Initialization of scale factors done!
                                  2023-07-06 15:01:21.976 - debug: modbus.0 (1808930) [DevID_247/holdingRegs] Poll address 33000 - 1 registers
                                  2023-07-06 15:01:22.177 - warn: modbus.0 (1808930) Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  2023-07-06 15:01:22.234 - debug: modbus.0 (1808930) [DevID_247/holdingRegs] Poll address 33000 DONE
                                  2023-07-06 15:01:22.283 - warn: modbus.0 (1808930) Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  2023-07-06 15:01:24.380 - warn: modbus.0 (1808930) Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  2023-07-06 15:01:24.472 - warn: modbus.0 (1808930) Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  2023-07-06 15:01:24.583 - warn: modbus.0 (1808930) Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  2023-07-06 15:01:24.778 - warn: modbus.0 (1808930) Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  2023-07-06 15:01:24.981 - warn: modbus.0 (1808930) Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  2023-07-06 15:01:25.342 - warn: modbus.0 (1808930) Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  2023-07-06 15:01:25.453 - warn: modbus.0 (1808930) Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  2023-07-06 15:01:27.548 - warn: modbus.0 (1808930) Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  2023-07-06 15:01:27.646 - warn: modbus.0 (1808930) Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  2023-07-06 15:01:27.750 - warn: modbus.0 (1808930) Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  2023-07-06 15:01:27.948 - warn: modbus.0 (1808930) Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  2023-07-06 15:01:28.148 - warn: modbus.0 (1808930) Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  2023-07-06 15:01:28.261 - warn: modbus.0 (1808930) Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  2023-07-06 15:01:30.279 - info: host.iOProduktiv "system.adapter.modbus.0" disabled
                                  2023-07-06 15:01:30.281 - info: host.iOProduktiv stopInstance system.adapter.modbus.0 (force=false, process=true)
                                  2023-07-06 15:01:30.350 - warn: modbus.0 (1808930) Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  2023-07-06 15:01:30.455 - warn: modbus.0 (1808930) Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  2023-07-06 15:01:30.565 - warn: modbus.0 (1808930) Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  2023-07-06 15:01:30.763 - warn: modbus.0 (1808930) Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  2023-07-06 15:01:30.979 - warn: modbus.0 (1808930) Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  2023-07-06 15:01:31.040 - info: modbus.0 (1808930) Got terminate signal TERMINATE_YOURSELF
                                  2023-07-06 15:01:31.077 - debug: modbus.0 (1808930) Closing client on purpose.
                                  2023-07-06 15:01:31.079 - info: modbus.0 (1808930) terminating
                                  2023-07-06 15:01:31.101 - debug: modbus.0 (1808930) Plugin sentry destroyed
                                  2023-07-06 15:01:31.102 - info: modbus.0 (1808930) Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                                  2023-07-06 15:01:31.104 - warn: modbus.0 (1808930) Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                                  2023-07-06 15:01:31.130 - debug: modbus.0 (1808930) Socket closed with error
                                  2023-07-06 15:01:31.131 - debug: modbus.0 (1808930) Clearing timeout of the current request.
                                  2023-07-06 15:01:31.136 - debug: modbus.0 (1808930) Cleaning up request fifo.
                                  2023-07-06 15:01:31.284 - info: host.iOProduktiv stopInstance system.adapter.modbus.0 send kill signal
                                  2023-07-06 15:01:32.401 - info: host.iOProduktiv instance system.adapter.modbus.0 terminated with code 11 (ADAPTER_REQUESTED_TERMINATION)
                                  

                                  @Homoran & @wendy2702 könnt ihr mir bitte eventuell noch bei den Registereinträgen helfen?

                                  354c424f-d3e2-4fa2-b534-c6b7fe8479a9-image.png

                                  Die 30000er sind holdingRegister
                                  Laut dieser Erklärung handelt es sich bei den 11xxxx um discrete Input Contacts, gebe ich im passenden Reiter z.B. 11028 ein, kann ich aber nicht UINIT32 und die Länge 2 einstellen.

                                  20221125_MTEC-EnergyButler_Modbus_RTU_Protkoll.pdf

                                  Danke im Voraus

                                  Homoran wendy2702 2 Replies Last reply Reply Quote 0
                                  • Homoran
                                    Homoran Global Moderator Administrators @metaxa last edited by

                                    @metaxa sagte in M-TEC Energy Butler:

                                    Die 30000er sind holdingRegister

                                    eigentlich nicht!
                                    Holdingregister sind 40000er.
                                    30000er sind Inputregister.

                                    @metaxa sagte in M-TEC Energy Butler:

                                    bei den 11xxxx um discrete Input Contacts,

                                    wären das weder noch, sondern diskrete Eingänge.

                                    metaxa 1 Reply Last reply Reply Quote 0
                                    • wendy2702
                                      wendy2702 @metaxa last edited by

                                      @metaxa im Spoiler ist ein Bild und kein Log.

                                      Wie sehen die Register einstellungen aktuell aus mit denen der Offset Fehler kommt ?

                                      metaxa 1 Reply Last reply Reply Quote 0
                                      • metaxa
                                        metaxa @wendy2702 last edited by

                                        @wendy2702 sagte in M-TEC Energy Butler:

                                        @metaxa im Spoiler ist ein Bild und kein Log.

                                        Entschldigung! Copy/Paste und nicht kontrolliert. schon ausgebessert in meinem Beitrag.

                                        @wendy2702 sagte in M-TEC Energy Butler:

                                        Wie sehen die Register einstellungen aktuell aus mit denen der Offset Fehler kommt ?

                                        6577c4c1-c754-4f6d-8908-a42d477beb04-image.png
                                        Wobei egal ist, ob ich bei Offset 0, 1, 2, oder 4 eintrage.

                                        Homoran 1 Reply Last reply Reply Quote 0
                                        • metaxa
                                          metaxa @Homoran last edited by

                                          @homoran sagte in M-TEC Energy Butler:

                                          30000er sind Inputregister.

                                          Super, poste selbst einen Link und lese ihn falsch oder scheinbar gar nicht 😞

                                          Jetzt habe ich die 33000 Adresse unter InputRegister eingetragen, leider bekomme ich keine Daten, nur eine andere Fehlermeldung.

                                          modbus.0
                                          2023-07-06 18:45:08.983	debug	Closing client on purpose.
                                          
                                          modbus.0
                                          2023-07-06 18:45:07.981	debug	Cleaning up request fifo.
                                          
                                          modbus.0
                                          2023-07-06 18:45:07.980	debug	Clearing timeout of the current request.
                                          
                                          modbus.0
                                          2023-07-06 18:45:07.979	debug	Socket closed with error
                                          
                                          modbus.0
                                          2023-07-06 18:45:07.977	info	Disconnected from slave 192.168.0.216
                                          
                                          modbus.0
                                          2023-07-06 18:45:07.976	debug	Closing client on purpose.
                                          
                                          modbus.0
                                          2023-07-06 18:45:07.925	warn	Poll error count: 7 code: "ReadInputRegisters: Invalid FC 3"
                                          

                                          Die 33000 eingetragen unter Holding brachte zwar Daten aber auch die Fehlermeldug wie schon oben beschrieben.

                                          1 Reply Last reply Reply Quote 0
                                          • Homoran
                                            Homoran Global Moderator Administrators @metaxa last edited by

                                            @metaxa sagte in M-TEC Energy Butler:

                                            Wobei egal ist, ob ich bei Offset 0, 1, 2, oder 4 eintrage.

                                            ich habe noch nie etwas bei Offset aktiv eingetragen 🤔

                                            @metaxa sagte in M-TEC Energy Butler:

                                            nur eine andere Fehlermeldung.

                                            FC3 muss etwas mit der internen Kommunikation zu tun haben.
                                            Bin da noch nicht fit drin.

                                            laut guhgell soll das read holding registers heißen.

                                            hab in der Doku zu deinem Butler nicht gefunden, ob die Adressen nur um 10000 verschoben sind (v2<->v3) und beide male Holdingregister sind, oder tatsächlich einmal holding und beim anderen input.

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            681
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            21
                                            201
                                            29670
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo