    5. [Unsolved but satisfied] For loop inside for loop

    NEWS

    • Neuer Blog: Fotos und Eindrücke aus Solingen

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    [Unsolved but satisfied] For loop inside for loop

    This topic has been deleted. Only users with topic management privileges can see it.
    • M
      MartiMan @paul53 last edited by

      @paul53 So fixed the length issue but now I'm having the errors as I had before when I only had one array.

      function Sync2Way() {
          const FunctionHeater = [
              "enum.functions.HeatingUp.setpoint",
              "enum.functions.HeatingUp.actual", 
              "enum.functions.HeatingUp.hum", 
              "enum.functions.HeatingUp.winStat", 
              "enum.functions.HeatingUp.profile", 
              "enum.functions.HeatingUp.boost", 
              "enum.functions.HeatingUp.boostTime"];
      
          const FunctionPLC = [
              "enum.functions.PlcHeatingUp.setpoint",
              "enum.functions.PlcHeatingUp.actual", 
              "enum.functions.PlcHeatingUp.hum", 
              "enum.functions.PlcHeatingUp.winStat", 
              "enum.functions.PlcHeatingUp.profile", 
              "enum.functions.PlcHeatingUp.boost", 
              "enum.functions.PlcHeatingUp.boostTime"];
      
          for(let j = 0; j < FunctionHeater.length; j++) {
              var Heater = getObject(FunctionHeater[j]).common.members;
              var PLC = getObject(FunctionPLC[j]).common.members;
              for(let i = 0; i < Heater.length; i++) {
                  on({id: [].concat([PLC[i]]),change: "ne"},async function (obj) {
                      let value = obj.state.val;
                      let oldValue = obj.oldState.val;
                      setStateDelayed(Heater[i], getState(PLC[i]).val, false, parseInt(((0) || "").toString(), 10), false);
                      //return;
                  });
                  on({id: [].concat([Heater[i]]),change: "ne"},async function (obj) {
                      let value = obj.state.val;
                      let oldValue = obj.oldState.val;
                      setStateDelayed(PLC[i], getState(Heater[i]).val, false, parseInt(((0) || "").toString(), 10), false);
                      //await wait(1500);
                  });
              }
          }
      }
      
      Sync2Way();
      
      14:42:22.207	info	javascript.0 (2003) Start javascript script.js.hmipS7BoostSync
      14:42:22.220	silly	admin.0 (1472) States system redis pmessage io.log.system.adapter.admin.0/io.log.system.adapter.admin.0:{"severity":"info","ts":1691152942207,"message":"javascript.0 (2003) Start javascript script.js.hmipS7BoostSync","from":"javascript.0","_id":76242388}
      14:42:22.218	info	javascript.0 (2003) script.js.hmipS7BoostSync: registered 86 subscriptions, 0 schedules, 0 messages, 0 logs and 0 file subscriptions
      14:42:22.222	silly	admin.0 (1472) States system redis pmessage io.log.system.adapter.admin.0/io.log.system.adapter.admin.0:{"severity":"info","ts":1691152942218,"message":"javascript.0 (2003) script.js.hmipS7BoostSync: registered 86 subscriptions, 0 schedules, 0 messages, 0 logs and 0 file subscriptions","from":"javascript.0","_id":76242389}
      14:42:25.025	warn	javascript.0 (2003) at Object.<anonymous> (script.js.hmipS7BoostSync:33:41)
      14:42:25.029	error	javascript.0 (2003) script.js.hmipS7BoostSync: TypeError: Cannot read properties of undefined (reading 'match')
      14:42:25.037	silly	admin.0 (1472) States system redis pmessage io.log.system.adapter.admin.0/io.log.system.adapter.admin.0:{"severity":"warn","ts":1691152945025,"message":"javascript.0 (2003) at Object.<anonymous> (script.js.hmipS7BoostSync:33:41)","from":"javascript.0","_id":76242391}
      14:42:25.040	silly	admin.0 (1472) States system redis pmessage io.log.system.adapter.admin.0/io.log.system.adapter.admin.0:{"severity":"error","ts":1691152945029,"message":"javascript.0 (2003) script.js.hmipS7BoostSync: TypeError: Cannot read properties of undefined (reading 'match')","from":"javascript.0","_id":76242396}
      14:42:25.030	error	javascript.0 (2003) at Object.<anonymous> (script.js.hmipS7BoostSync:33:17)
      14:42:25.049	silly	admin.0 (1472) States system redis pmessage io.log.system.adapter.admin.0/io.log.system.adapter.admin.0:{"severity":"error","ts":1691152945030,"message":"javascript.0 (2003) at Object.<anonymous> (script.js.hmipS7BoostSync:33:17)","from":"javascript.0","_id":76242400}
      14:42:28.554	silly	admin.0 (1472) Objects user redis pmessage */cfg.o.script.js.hmipS7BoostSync:{"common":{"name":"hmipS7BoostSync","expert":true,"engineType":"Javascript/js","engine":"system.adapter.javascript.0","source":"function Sync2Way() {\r\n const FunctionHeater = [\r\n \"enum.functions.HeatingUp.setpoint\",\r\n \"enum.functions.HeatingUp.actual\", \r\n \"enum.functions.HeatingUp.hum\", \r\n \"enum.functions.HeatingUp.winStat\", \r\n \"enum.functions.HeatingUp.profile\", \r\n \"enum.functions.HeatingUp.boost\", \r\n \"enum.functions.HeatingUp.boostTime\"];\r\n\r\n const FunctionPLC = [\r\n \"enum.functions.PlcHeatingUp.setpoint\",\r\n \"enum.functions.PlcHeatingUp.actual\", \r\n \"enum.functions.PlcHeatingUp.hum\", \r\n \"enum.functions.PlcHeatingUp.winStat\", \r\n \"enum.functions.PlcHeatingUp.profile\", \r\n \"enum.functions.PlcHeatingUp.boost\", \r\n \"enum.functions.PlcHeatingUp.boostTime\"];\r\n\r\n for(let j = 0; j < FunctionHeater.length; j++) {\r\n var Heater = getObject(FunctionHeater[j]).common.members;\r\n var PLC = getObject(FunctionPLC[j]).common.members;\r\n for(let i = 0; i < Heater.length; i++) {\r\n on({id: [].concat([PLC[i]]),change: \"ne\"},async function (obj) {\r\n let value = obj.state.val;\r\n let oldValue = obj.oldState.val;\r\n setStateDelayed(Heater[i], getState(PLC[i]).val, false, parseInt(((0) || \"\").toString(), 10), false);\r\n //return;\r\n });\r\n on({id: [].concat([Heater[i]]),change: \"ne\"},async function (obj) {\r\n let value = obj.state.val;\r\n let oldValue = obj.oldState.val;\r\n setStateDelayed(PLC[i], getState(Heater[i]).val, false, parseInt(((0) || \"\").toString(), 10), false);\r\n //await wait(1500);\r\n });\r\n }\r\n }\r\n}\r\n\r\nSync2Way();","debug":false,"verbose":false,"enabled":false},"type":"script","from":"system.adapter.admin.0","user":"system.user.admin","ts":1691152948552,"_id":"script.js.hmipS7BoostSync","acl":{"object":1636,"owner":"system.user.admin","ownerGroup":"system.group.administrator"}}
      14:42:28.556	info	javascript.0 (2003) Stop script script.js.hmipS7BoostSync
      

      Any idea?

      paul53 1 Reply Last reply Reply Quote 0
      • paul53
        paul53 @MartiMan last edited by paul53

        @martiman
        Try:

                    on(PLC[i], function (dp) {
                        if(dp.state.c != scriptName) setState(Heater[i], dp.state.val);
                    });
                    on(Heater[i], function (dp) {
                        if(dp.state.c != scriptName) setState(PLC[i], dp.state.val);
                    });
        
        M 1 Reply Last reply Reply Quote 0
        • paul53
          paul53 @MartiMan last edited by

          @martiman sagte: Any idea?

          No. All 14 arrays of members are complete?

          1 Reply Last reply Reply Quote 0
          • M
            MartiMan @paul53 last edited by

            @paul53 said in For loop inside for loop:

            on(PLC[i], function (dp) { if(dp.state.c != scriptName) setState(Heater[i], dp.state.val); }); on(Heater[i], function (dp) { if(dp.state.c != scriptName) setState(PLC[i], dp.state.val); });

            I'm using blockly and use the JS code there to puzzle this together...
            So thanks, I would never have come to this adjustment.

            Well less warnings but still:

            15:01:29.667	info	javascript.0 (2003) Start javascript script.js.hmipS7BoostSync
            15:01:29.687	silly	admin.0 (1472) States system redis pmessage io.log.system.adapter.admin.0/io.log.system.adapter.admin.0:{"severity":"info","ts":1691154089667,"message":"javascript.0 (2003) Start javascript script.js.hmipS7BoostSync","from":"javascript.0","_id":76242545}
            15:01:29.684	info	javascript.0 (2003) script.js.hmipS7BoostSync: registered 86 subscriptions, 0 schedules, 0 messages, 0 logs and 0 file subscriptions
            15:01:29.689	silly	admin.0 (1472) States system redis pmessage io.log.system.adapter.admin.0/io.log.system.adapter.admin.0:{"severity":"info","ts":1691154089684,"message":"javascript.0 (2003) script.js.hmipS7BoostSync: registered 86 subscriptions, 0 schedules, 0 messages, 0 logs and 0 file subscriptions","from":"javascript.0","_id":76242546}
            15:01:31.907	error	javascript.0 (2003) at Object.<anonymous> (script.js.hmipS7BoostSync:28:46)
            15:01:31.947	silly	admin.0 (1472) States system redis pmessage io.log.system.adapter.admin.0/io.log.system.adapter.admin.0:{"severity":"error","ts":1691154091907,"message":"javascript.0 (2003) at Object.<anonymous> (script.js.hmipS7BoostSync:28:46)","from":"javascript.0","_id":76242550}
            15:01:36.127	silly	admin.0 (1472) Objects user redis pmessage */cfg.o.script.js.hmipS7BoostSync:{"common":{"name":"hmipS7BoostSync","expert":true,"engineType":"Javascript/js","engine":"system.adapter.javascript.0","source":"function Sync2Way() {\r\n const FunctionHeater = [\r\n \"enum.functions.HeatingUp.setpoint\",\r\n \"enum.functions.HeatingUp.actual\", \r\n \"enum.functions.HeatingUp.hum\", \r\n \"enum.functions.HeatingUp.winStat\", \r\n \"enum.functions.HeatingUp.profile\", \r\n \"enum.functions.HeatingUp.boost\", \r\n \"enum.functions.HeatingUp.boostTime\"];\r\n\r\n const FunctionPLC = [\r\n \"enum.functions.PlcHeatingUp.setpoint\",\r\n \"enum.functions.PlcHeatingUp.actual\", \r\n \"enum.functions.PlcHeatingUp.hum\", \r\n \"enum.functions.PlcHeatingUp.winStat\", \r\n \"enum.functions.PlcHeatingUp.profile\", \r\n \"enum.functions.PlcHeatingUp.boost\", \r\n \"enum.functions.PlcHeatingUp.boostTime\"];\r\n\r\n for(let j = 0; j < FunctionHeater.length; j++) {\r\n var Heater = getObject(FunctionHeater[j]).common.members;\r\n var PLC = getObject(FunctionPLC[j]).common.members;\r\n for(let i = 0; i < Heater.length; i++) {\r\n on(PLC[i], function (dp) {\r\n if(dp.state.c != scriptName) setState(Heater[i], dp.state.val);\r\n });\r\n on(Heater[i], function (dp) {\r\n if(dp.state.c != scriptName) setState(PLC[i], dp.state.val);\r\n });\r\n }\r\n }\r\n}\r\n\r\nSync2Way();","debug":false,"verbose":false,"enabled":false},"type":"script","from":"system.adapter.admin.0","user":"system.user.admin","ts":1691154096121,"_id":"script.js.hmipS7BoostSync","acl":{"object":1636,"owner":"system.user.admin","ownerGroup":"system.group.administrator"}}
            15:01:36.129	info	javascript.0 (2003) Stop script script.js.hmipS7BoostSync
            

            To give you an idea, this is one of the arrays of the bool on the hmip side of what I try to sync to the PLC:

            {
              "type": "enum",
              "common": {
                "name": "Boost",
                "enabled": true,
                "color": false,
                "desc": "",
                "members": [
                  "hmip.0.groups.b29b9bef-cdda-491c-b664-2d8edcd540a8.boostMode",
                  "hmip.0.groups.1d81098a-ef8e-4aaf-bdac-871e3de74127.boostMode",
                  "hmip.0.groups.0b3141dc-92d8-4231-ba4e-d50128ea30cf.boostMode",
                  "hmip.0.groups.47dbff3e-8ee5-436d-9bcf-11a40bb5801d.boostMode",
                  "hmip.0.groups.44690c2e-d317-4969-aef0-d50c6041a3d5.boostMode",
                  "hmip.0.groups.f28a0397-3999-4759-a7d7-63446e4131cf.boostMode",
                  "hmip.0.groups.e181e361-bd13-4cb0-873d-5990d35bb1bc.boostMode"
                ]
              },
              "native": {},
              "_id": "enum.functions.HeatingUp.boost",
              "acl": {
                "object": 1636,
                "owner": "system.user.admin",
                "ownerGroup": "system.group.administrator"
              },
              "from": "system.adapter.admin.0",
              "user": "system.user.admin",
              "ts": 1691077099049
            }
            

            This is the other side:

            {
              "type": "enum",
              "common": {
                "name": "Boost",
                "enabled": true,
                "color": false,
                "desc": "",
                "members": [
                  "s7.2.DBs.DB5.GR_Therm_Boost",
                  "s7.2.DBs.DB5.GR_Therm_Bath_Boost",
                  "s7.2.DBs.DB5.CRD_Therm_Boost",
                  "s7.2.DBs.DB5.LNG_Therm_Boost",
                  "s7.2.DBs.DB5.KR1_Therm_Boost",
                  "s7.2.DBs.DB5.KR2_Therm_Boost",
                  "s7.2.DBs.DB5.KRB_Therm_Boost"
                ]
              },
              "native": {},
              "_id": "enum.functions.PlcHeatingUp.boost",
              "acl": {
                "object": 1636,
                "owner": "system.user.admin",
                "ownerGroup": "system.group.administrator"
              },
              "from": "system.adapter.admin.0",
              "user": "system.user.admin",
              "ts": 1691077151135
            }
            

            Sync in both directions gives me the error.

            paul53 1 Reply Last reply Reply Quote 0
            • paul53
              paul53 @MartiMan last edited by paul53

              @martiman sagte: Sync in both directions gives me the error.

              Check all IDs:

                          log('Heater: ' + Heater[i] + ', PLC: ' + PLC[i]);
                          on(PLC[i], function (dp) {
                              if(dp.state.c != scriptName) setState(Heater[i], dp.state.val);
                          });
                          on(Heater[i], function (dp) {
                              if(dp.state.c != scriptName) setState(PLC[i], dp.state.val);
                          });
              

              The data point type is identical on both sides?

              M 2 Replies Last reply Reply Quote 1
              • M
                MartiMan @paul53 last edited by

                @paul53 Hi, having a little mental breakdown at the moment... 😠
                Like I wrote in the beginning, all instances work in their own separate script.
                Now I started checking them again and ioBroker is throwing me GUI errors and all I had this morning doesn't work anymore...
                Even if I reroute all to dummy tags in Userdata_0 it doesn't work anymore.
                Also after numerous reboots and restoring backups.
                So uhm, I'm about to open a 🍺 and call it a day...

                1 Reply Last reply Reply Quote 0
                • M
                  MartiMan @paul53 last edited by MartiMan

                  @paul53 Well I kicked out Edge and installed Chrome, less GUI errors now.
                  I also found that S7STRING in the S7 adapter needs to be declared as 32 length which was the main error.

                  So I still have 2 issues:

                  • Loop inside loop still not working

                  • Edge detection is responding to being sync'd by the other one

                  First the loop in loop:

                  Code below works flawlessly (besides the updater being updated and so on)

                  function SyncSetpoint() {
                      var Heater = getObject("enum.functions.HeatingUp.setpoint").common.members;
                      var PLC = getObject("enum.functions.PlcHeatingUp.setpoint").common.members;
                      for(let i = 0; i < Heater.length; i++) {
                          on(PLC[i], function (dp) {
                              if(dp.state.c != scriptName) setState(Heater[i], dp.state.val);
                              return;
                          });
                          on(Heater[i], function (dp) {
                              if(dp.state.c != scriptName) setState(PLC[i], dp.state.val);
                          });            
                      }
                  }
                      
                  function SyncProfile() {
                      var Heater = getObject("enum.functions.HeatingUp.profile").common.members;
                      var PLC = getObject("enum.functions.PlcHeatingUp.profile").common.members;
                      for(let i = 0; i < Heater.length; i++) {
                          on(PLC[i], function (dp) {
                              if(dp.state.c != scriptName) setState(Heater[i], dp.state.val);
                              return;
                          });
                          on(Heater[i], function (dp) {
                              if(dp.state.c != scriptName) setState(PLC[i], dp.state.val);
                          });            
                      }
                  }
                      
                  function SyncBoost() {
                      var Heater = getObject("enum.functions.HeatingUp.boost").common.members;
                      var PLC = getObject("enum.functions.PlcHeatingUp.boost").common.members;
                      for(let i = 0; i < Heater.length; i++) {
                          on(PLC[i], function (dp) {
                              if(dp.state.c != scriptName) setState(Heater[i], dp.state.val);
                              return;
                          });
                          on(Heater[i], function (dp) {
                              if(dp.state.c != scriptName) setState(PLC[i], dp.state.val);
                          });            
                      }
                  }
                      
                  function SyncBoostTime() {
                      var Heater = getObject("enum.functions.HeatingUp.boostTime").common.members;
                      var PLC = getObject("enum.functions.PlcHeatingUp.boostTime").common.members;
                      for(let i = 0; i < Heater.length; i++) {
                          on(PLC[i], function (dp) {
                              if(dp.state.c != scriptName) setState(Heater[i], dp.state.val);
                              return;
                          });
                          on(Heater[i], function (dp) {
                              if(dp.state.c != scriptName) setState(PLC[i], dp.state.val);
                          });            
                      }
                  }
                  
                  
                  SyncSetpoint();
                  
                  SyncProfile();
                  
                  SyncBoost();
                  
                  SyncBoostTime();
                  

                  The code below does not:

                  function Sync2Way() {
                  const FunctionHeater = [
                      "enum.functions.HeatingUp.setpoint",
                      "enum.functions.HeatingUp.profile", 
                      "enum.functions.HeatingUp.boost", 
                      "enum.functions.HeatingUp.boostTime"
                      ];
                   
                  const FunctionPLC = [
                      "enum.functions.PlcHeatingUp.setpoint",
                      "enum.functions.PlcHeatingUp.profile", 
                      "enum.functions.PlcHeatingUp.boost", 
                      "enum.functions.PlcHeatingUp.boostTime"
                      ];
                  
                  
                      for(let j = 0; j < FunctionHeater.length; j++) {
                          var Heater = getObject(FunctionHeater[j]).common.members;
                          var PLC = getObject(FunctionPLC[j]).common.members;
                          for(let i = 0; i < Heater.length; i++) {
                              log('Heater: ' + Heater[i] + ', PLC: ' + PLC[i]);
                              on(PLC[i], function (dp) {
                                  if(dp.state.c != scriptName) setState(Heater[i], dp.state.val);
                                  return;
                                  });
                              on(Heater[i], function (dp) {
                                  if(dp.state.c != scriptName) setState(PLC[i], dp.state.val);
                                  });            
                          }
                      }
                  }
                  
                  Sync2Way();
                  

                  Strange thing is that the setpoint (REAL) and the boost time (INT) don't trigger the "on" function, no response in the log at all.
                  The profile (STRING) and boost (BOOL) do and give following error.

                  17:07:08.747	warn	javascript.0 (1494) at Object.<anonymous> (script.js.Test:23:46)
                  17:07:08.755	silly	admin.0 (1466) States system redis pmessage io.log.system.adapter.admin.0/io.log.system.adapter.admin.0:{"severity":"warn","ts":1691248028747,"message":"javascript.0 (1494) at Object.<anonymous> (script.js.Test:23:46)","from":"javascript.0","_id":14262598}
                  17:07:22.639	warn	javascript.0 (1494) at Object.<anonymous> (script.js.Test:23:46)
                  17:07:22.644	silly	admin.0 (1466) States system redis pmessage io.log.system.adapter.admin.0/io.log.system.adapter.admin.0:{"severity":"warn","ts":1691248042639,"message":"javascript.0 (1494) at Object.<anonymous> (script.js.Test:23:46)","from":"javascript.0","_id":14262606}
                  

                  Edge detection is responding to being triggered

                  Your alteration works very smooth but originally I put in a wait command because the edge detection gets in a loop.

                  For the Heater edge sync I added "return;" which helps a bit to avoid a loop but it still fluctuates a couple of times when values are changed ON and OFF.
                  The reason for the loop is the hmip device communication, when you activate boost (also in their iOS app, not just ioBroker), it will go on-off-on.

                  Any idea how to block the "on(Heater[i]..." when it's being updated by the "on(PLC[i]..." and vice versa?
                  Found some delay and wait instructions but that will pause the whole script no?
                  I'd like to only cancel the feedback read for like say 5 seconds after the value was sync'd.

                  In S7 I would simply put an ODT before the edge, triggered by the other edge 😉

                  paul53 2 Replies Last reply Reply Quote 0
                  • paul53
                    paul53 @MartiMan last edited by

                    @martiman sagte: Any idea how to block the "on(Heater[i]..." when it's being updated by the "on(PLC[i]..." and vice versa?

                    if(dp.state.c != scriptName) 
                    

                    is to prevent the trigger infinite loop.

                    M 1 Reply Last reply Reply Quote 0
                    • M
                      MartiMan @paul53 last edited by

                      @paul53 said in For loop inside for loop:

                      is to prevent the trigger infinite loop.

                      Well it's apparently not enough 😅

                      I think the arrays are not being synchronised in the for loop as I got this log:

                      javascript.0
                      2023-08-05 17:41:51.811	warn	You are assigning a boolean to the state "hmip.0.groups.47dbff3e-8ee5-436d-9bcf-11a40bb5801d.boostDuration" which expects a number. Please fix your code to use a number or change the state type to boolean. This warning might become an error in future versions.
                      
                      1 Reply Last reply Reply Quote 0
                      • paul53
                        paul53 @MartiMan last edited by

                        @martiman sagte: The code below does not:

                        Try to slow down the loop with async ( line 1) and await wait(100).

                        async function Sync2Way() {
                            const FunctionHeater = [
                                "enum.functions.HeatingUp.setpoint",
                                "enum.functions.HeatingUp.actual", 
                                "enum.functions.HeatingUp.hum", 
                                "enum.functions.HeatingUp.winStat", 
                                "enum.functions.HeatingUp.profile", 
                                "enum.functions.HeatingUp.boost", 
                                "enum.functions.HeatingUp.boostTime"];
                         
                            const FunctionPLC = [
                                "enum.functions.PlcHeatingUp.setpoint",
                                "enum.functions.PlcHeatingUp.actual", 
                                "enum.functions.PlcHeatingUp.hum", 
                                "enum.functions.PlcHeatingUp.winStat", 
                                "enum.functions.PlcHeatingUp.profile", 
                                "enum.functions.PlcHeatingUp.boost", 
                                "enum.functions.PlcHeatingUp.boostTime"];
                         
                            for(let j = 0; j < FunctionHeater.length; j++) {
                                var Heater = getObject(FunctionHeater[j]).common.members;
                                var PLC = getObject(FunctionPLC[j]).common.members;
                                for(let i = 0; i < Heater.length; i++) {
                                    log('Heater: ' + Heater[i] + ', PLC: ' + PLC[i]);
                                    on(PLC[i], function (dp) {
                                        if(dp.state.c != scriptName) setState(Heater[i], dp.state.val);
                                    });
                                    on(Heater[i], function (dp) {
                                        if(dp.state.c != scriptName) setState(PLC[i], dp.state.val);
                                    });
                                    await wait(100);
                                }
                            }
                        }
                         
                        Sync2Way();
                        
                        M 1 Reply Last reply Reply Quote 1
                        • M
                          MartiMan @paul53 last edited by

                          @paul53 said in For loop inside for loop:

                                                                                                                                                      async function Sync2Way() {                                                                                                                                                                                const FunctionHeater = [                                                                                                                                                                                    "enum.functions.HeatingUp.setpoint",                                                                                                                                                                                    "enum.functions.HeatingUp.actual",                                                                                                                                                                                     "enum.functions.HeatingUp.hum",                                                                                                                                                                                     "enum.functions.HeatingUp.winStat",                                                                                                                                                                                     "enum.functions.HeatingUp.profile",                                                                                                                                                                                     "enum.functions.HeatingUp.boost",                                                                                                                                                                                     "enum.functions.HeatingUp.boostTime"];                                                                                                                                                                                                                                                                                                                                                             const FunctionPLC = [                                                                                                                                                                                    "enum.functions.PlcHeatingUp.setpoint",                                                                                                                                                                                    "enum.functions.PlcHeatingUp.actual",                                                                                                                                                                                     "enum.functions.PlcHeatingUp.hum",                                                                                                                                                                                     "enum.functions.PlcHeatingUp.winStat",                                                                                                                                                                                     "enum.functions.PlcHeatingUp.profile",                                                                                                                                                                                     "enum.functions.PlcHeatingUp.boost",                                                                                                                                                                                     "enum.functions.PlcHeatingUp.boostTime"];                                                                                                                                                                                                                                                                                                                                                             for(let j = 0; j < FunctionHeater.length; j++) {                                                                                                                                                                                    var Heater = getObject(FunctionHeater[j]).common.members;                                                                                                                                                                                    var PLC = getObject(FunctionPLC[j]).common.members;                                                                                                                                                                                    for(let i = 0; i < Heater.length; i++) {                                                                                                                                                                                        log('Heater: ' + Heater[i] + ', PLC: ' + PLC[i]);                                                                                                                                                                                        on(PLC[i], function (dp) {                                                                                                                                                                                            if(dp.state.c != scriptName) setState(Heater[i], dp.state.val);                                                                                                                                                                                        });                                                                                                                                                                                        on(Heater[i], function (dp) {                                                                                                                                                                                            if(dp.state.c != scriptName) setState(PLC[i], dp.state.val);                                                                                                                                                                                        });                                                                                                                                                                                        await wait(100);                                                                                                                                                                                    }                                                                                                                                                                                }                                                                                                                                                                            }                                                                                                                                                                                                                                                                                                                                                         Sync2Way();                                            
                          

                          Thanks, but still same issue.

                          If I use an array of only 2 and swap the order, it works 🤣

                          1 Reply Last reply Reply Quote 0
                          • M
                            MartiMan last edited by

                            @paul53 BTW thanks for the async declaration and await!
                            I read await was not possible in a sync function so skipped trying it.

                            If I put await for 1000ms it blocks the back and forth updating due to the hmip communication inconsistency.
                            Again, I'm really newby when it comes to scripting 😅

                            1 Reply Last reply Reply Quote 0
                            • M
                              MartiMan last edited by MartiMan

                              So I decided to drop the loop inside loop as the arrays were not synchronising.

                              The time to troubleshoot would be more than the loop would save me time from programming the full code bit by bit.

                              Just for future reference if someone wants to do the same:
                              The "First_Run" bit is to fill the PLC DB so it doesn't overwrite the actual settings with an empty DB.

                              async function SyncSetpoint() {
                                  var Heater = getObject("enum.functions.HeatingUp.setpoint").common.members;
                                  var PLC = getObject("enum.functions.PlcHeatingUp.setpoint").common.members;
                                  for(let i = 0; i < Heater.length; i++) {
                                      on(PLC[i], function (dp) {
                                          if(dp.state.c != scriptName) setState(Heater[i], dp.state.val);
                                          return;
                                      });
                                      on(Heater[i], function (dp) {
                                          if(dp.state.c != scriptName) setState(PLC[i], dp.state.val);
                                      });
                                      await wait(1000);            
                                  }
                              }
                                  
                              async function SyncProfile() {
                                  var Heater = getObject("enum.functions.HeatingUp.profile").common.members;
                                  var PLC = getObject("enum.functions.PlcHeatingUp.profile").common.members;
                                  for(let i = 0; i < Heater.length; i++) {
                                      on(PLC[i], function (dp) {
                                          if(dp.state.c != scriptName) setState(Heater[i], dp.state.val);
                                          return;
                                      });
                                      on(Heater[i], function (dp) {
                                          if(dp.state.c != scriptName) setState(PLC[i], dp.state.val);
                                      });
                                      await wait(1000);            
                                  }
                              }
                                  
                              async function SyncBoost() {
                                  var Heater = getObject("enum.functions.HeatingUp.boost").common.members;
                                  var PLC = getObject("enum.functions.PlcHeatingUp.boost").common.members;
                                  for(let i = 0; i < Heater.length; i++) {
                                      on(PLC[i], function (dp) {
                                          if(dp.state.c != scriptName) setState(Heater[i], dp.state.val);
                                          return;
                                      });
                                      on(Heater[i], function (dp) {
                                          if(dp.state.c != scriptName) setState(PLC[i], dp.state.val);
                                      });
                                      await wait(1000);            
                                  }
                              }
                                  
                              async function SyncBoostTime() {
                                  var Heater = getObject("enum.functions.HeatingUp.boostTime").common.members;
                                  var PLC = getObject("enum.functions.PlcHeatingUp.boostTime").common.members;
                                  for(let i = 0; i < Heater.length; i++) {
                                      on(PLC[i], function (dp) {
                                          if(dp.state.c != scriptName) setState(Heater[i], dp.state.val);
                                          return;
                                      });
                                      on(Heater[i], function (dp) {
                                          if(dp.state.c != scriptName) setState(PLC[i], dp.state.val);
                                      });
                                      await wait(1000);            
                                  }
                              }
                              
                              function SyncActualTemp() {
                                  var Heater = getObject("enum.functions.HeatingUp.actual").common.members;
                                  var PLC = getObject("enum.functions.PlcHeatingUp.actual").common.members;
                                  for(let i = 0; i < Heater.length; i++) {
                                      on(Heater[i], function (dp) {
                                          if(dp.state.c != scriptName) setState(PLC[i], dp.state.val);
                                      });            
                                  }
                              }
                              
                              function SyncActualHum() {
                                  var Heater = getObject("enum.functions.HeatingUp.hum").common.members;
                                  var PLC = getObject("enum.functions.PlcHeatingUp.hum").common.members;
                                  for(let i = 0; i < Heater.length; i++) {
                                      on(Heater[i], function (dp) {
                                          if(dp.state.c != scriptName) setState(PLC[i], dp.state.val);
                                      });            
                                  }
                              }
                              
                              function SyncWinStat() {
                                  var connStatHeater = getObject("enum.functions.HeatingUp.connStatWin").common.members;
                                  var connStatPLC = getObject("enum.functions.PlcHeatingUp.connStatWin").common.members;
                                  var winStatHeater = getObject("enum.functions.HeatingUp.winStat").common.members;
                                  var winStatPLC = getObject("enum.functions.PlcHeatingUp.winStat").common.members;
                                  var batStatHeater = getObject("enum.functions.HeatingUp.batStatWin").common.members;
                                  var batStatPLC = getObject("enum.functions.PlcHeatingUp.batStatWin").common.members;
                                  for(let i = 0; i < connStatPLC.length; i++) {
                                      on(connStatHeater[i], function (dp) {
                                          if(dp.state.c != scriptName) setState(connStatPLC[i], dp.state.val);
                                      });
                                      if (getState(connStatHeater[i]).val != true) {
                                          on(winStatHeater[i], function (dp) {
                                              if(dp.state.c != scriptName) setState(winStatPLC[i], dp.state.val);
                                          });            
                                          on(batStatHeater[i], function (dp) {
                                              if(dp.state.c != scriptName) setState(batStatPLC[i], dp.state.val);
                                          });
                                      }            
                                  }
                              }
                              
                              function SyncThermStat() {
                                  var connStatHeater = getObject("enum.functions.HeatingUp.connStatTherm").common.members;
                                  var connStatPLC = getObject("enum.functions.PlcHeatingUp.connStatTherm").common.members;
                                  var batStatHeater = getObject("enum.functions.HeatingUp.batStatTherm").common.members;
                                  var batStatPLC = getObject("enum.functions.PlcHeatingUp.batStatTherm").common.members;
                                  for(let i = 0; i < connStatPLC.length; i++) {
                                      on(connStatHeater[i], function (dp) {
                                          if(dp.state.c != scriptName) setState(connStatPLC[i], dp.state.val);
                                      });
                                      if (getState(connStatHeater[i]).val != true) {
                                          on(batStatHeater[i], function (dp) {
                                              if(dp.state.c != scriptName) setState(batStatPLC[i], dp.state.val);
                                          });
                                      }            
                                  }
                              }
                              
                              function SyncRadStat() {
                                  var connStatHeater = getObject("enum.functions.HeatingUp.connStatRad").common.members;
                                  var connStatPLC = getObject("enum.functions.PlcHeatingUp.connStatRad").common.members;
                                  var batStatHeater = getObject("enum.functions.HeatingUp.batStatRad").common.members;
                                  var batStatPLC = getObject("enum.functions.PlcHeatingUp.batStatRad").common.members;
                                  for(let i = 0; i < connStatPLC.length; i++) {
                                      on(connStatHeater[i], function (dp) {
                                          if(dp.state.c != scriptName) setState(connStatPLC[i], dp.state.val);
                                      });
                                      if (getState(connStatHeater[i]).val != true) {
                                          on(batStatHeater[i], function (dp) {
                                              if(dp.state.c != scriptName) setState(batStatPLC[i], dp.state.val);
                                          });
                                      }            
                                  }
                              }
                              
                              //function SyncOnStart() {
                              on({id: "s7.2.DBs.DB5.First_Run"/*First_Run*/, change: "ne"}, async function (obj) {
                                  var SPHeater = getObject("enum.functions.HeatingUp.setpoint").common.members;
                                  var SPPLC = getObject("enum.functions.PlcHeatingUp.setpoint").common.members;
                                  var TempHeater = getObject("enum.functions.HeatingUp.actual").common.members;
                                  var TempPLC = getObject("enum.functions.PlcHeatingUp.actual").common.members;
                                  var HumHeater = getObject("enum.functions.HeatingUp.hum").common.members;
                                  var HumPLC = getObject("enum.functions.PlcHeatingUp.hum").common.members;
                                  var ProfileHeater = getObject("enum.functions.HeatingUp.profile").common.members;
                                  var ProfilePLC = getObject("enum.functions.PlcHeatingUp.profile").common.members;
                                  var BoostHeater = getObject("enum.functions.HeatingUp.boost").common.members;
                                  var BoostPLC = getObject("enum.functions.PlcHeatingUp.boost").common.members;
                                  var BoostTimeHeater = getObject("enum.functions.HeatingUp.boostTime").common.members;
                                  var BoostTimePLC = getObject("enum.functions.PlcHeatingUp.boostTime").common.members;
                              
                                  var WinStatHeater = getObject("enum.functions.HeatingUp.winStat").common.members;
                                  var WinStatPLC = getObject("enum.functions.PlcHeatingUp.winStat").common.members;
                              
                                  var batStatRadHeater = getObject("enum.functions.HeatingUp.batStatRad").common.members;
                                  var batStatRadPLC = getObject("enum.functions.PlcHeatingUp.batStatRad").common.members;
                                  var connStatRadHeater = getObject("enum.functions.HeatingUp.connStatRad").common.members;
                                  var connStatRadPLC = getObject("enum.functions.PlcHeatingUp.connStatRad").common.members;
                              
                                  var batStatThermHeater = getObject("enum.functions.HeatingUp.batStatTherm").common.members;
                                  var batStatThermPLC = getObject("enum.functions.PlcHeatingUp.batStatTherm").common.members;
                                  var connStatThermHeater = getObject("enum.functions.HeatingUp.connStatTherm").common.members;
                                  var connStatThermPLC = getObject("enum.functions.PlcHeatingUp.connStatTherm").common.members;
                              
                                  let value = obj.state.val;
                                  let oldValue = obj.oldState.val;
                                  if (getState("s7.2.DBs.DB5.First_Run").val == true) {
                              
                                      for(let i = 0; i < SPHeater.length; i++) {
                                          setStateDelayed(SPPLC[i], getState(SPHeater[i]).val, false, parseInt(((0) || "").toString(), 10), false);
                                          setStateDelayed(TempPLC[i], getState(TempHeater[i]).val, false, parseInt(((0) || "").toString(), 10), false);
                                          setStateDelayed(HumPLC[i], getState(HumHeater[i]).val, false, parseInt(((0) || "").toString(), 10), false);
                                          setStateDelayed(ProfilePLC[i], getState(ProfileHeater[i]).val, false, parseInt(((0) || "").toString(), 10), false);
                                          setStateDelayed(BoostPLC[i], getState(BoostHeater[i]).val, false, parseInt(((0) || "").toString(), 10), false);
                                          setStateDelayed(BoostTimePLC[i], getState(BoostTimeHeater[i]).val, false, parseInt(((0) || "").toString(), 10), false);
                                      };
                                      for(let i = 0; i < WinStatHeater.length; i++) {
                                      setStateDelayed(WinStatPLC[i], getState(WinStatHeater[i]).val, false, parseInt(((0) || "").toString(), 10), false);
                                      };
                                      for(let i = 0; i < batStatRadHeater.length; i++) {
                                          setStateDelayed(batStatRadPLC[i], getState(batStatRadHeater[i]).val, false, parseInt(((0) || "").toString(), 10), false);
                                          setStateDelayed(connStatRadPLC[i], getState(connStatRadHeater[i]).val, false, parseInt(((0) || "").toString(), 10), false);
                                      };
                                      for(let i = 0; i < batStatThermHeater.length; i++) {
                                          setStateDelayed(batStatThermPLC[i], getState(batStatThermHeater[i]).val, false, parseInt(((0) || "").toString(), 10), false);
                                          setStateDelayed(connStatThermPLC[i], getState(connStatThermHeater[i]).val, false, parseInt(((0) || "").toString(), 10), false);
                                      };
                                      await wait(3000);
                                      setStateDelayed("s7.2.DBs.DB5.First_Run", false, false, parseInt(((0) || "").toString(), 10), false);
                                  }  
                              });
                              
                              
                              SyncSetpoint();
                              SyncProfile();
                              SyncBoost();
                              SyncBoostTime();
                              SyncActualHum();
                              SyncWinStat();
                              SyncThermStat();
                              SyncRadStat();
                              

                              So thanks @paul53 but I gave up and took the less beautiful way out 😉

                              1 Reply Last reply Reply Quote 0
                              • First post
                                Last post

                              Support us

                              ioBroker
                              Community Adapters
                              Donate

                              779
                              Online

                              31.8k
                              Users

                              80.0k
                              Topics

                              1.3m
                              Posts

                              2
                              16
                              879
                              Loading More Posts
                              • Oldest to Newest
                              • Newest to Oldest
                              • Most Votes
                              Reply
                              • Reply as topic
                              Log in to reply
                              Community
                              Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                              The ioBroker Community 2014-2023
                              logo