      @ralla66 ,
      hmm gut und wie machen wir weiter ?
      Eins nach dem anderen hinzufügen ?

      >D
      SW=0
      rSW="01060002000"
      vSW=""
      >B
      ->sensor53 r
      >W
      bu(SW "DPM Ein" "DPM Aus")
      >T
      if ((chg[SW]>0)
      then
        vSW=rSW+s(SW)
        sml(1 3 vSW)
      endif
      >M 1
      +1,3,m,16,9600,DC,1,2,010300000001,010300010001,010300020001,010310010001,010310020001,010310030001
      1,010302SSssxxxx@i0:100,Spannung (set),V,sVolt,2
      1,010302SSssxxxx@i1:1000,Strom (set),A,sCur,2
      1,010302SSssxxxx@i2:1,Ausgang (set),,sSwitch,0
      1,010302SSssxxxx@i3:100,Spannung (disp),V,dVolt,2
      1,010302SSssxxxx@i4:1000,Strom (disp),A,vCur,2
      1,010302SSssxxxx@i5:1,Temp,°C,tCur,1
      #
      
      Ralla66 1 Reply Last reply Reply Quote 0
      • Ralla66
        Ralla66 Most Active @Wal last edited by Ralla66

        @wal

        was passiert hier :
        if ((chg[SW]>0)
        wenn der Zustand des Web Gui Switch wechselt und >0 ist ?
        Also Switch Web Gui muß 1 sein ?

        Nachtrag 2 Script geht auch 🙂 Es wird

        Wal 1 Reply Last reply Reply Quote 0
        • Wal
          Wal Developer @Ralla66 last edited by

          @ralla66 ,
          SW Groß geschrieben ist der Status des Buttons.

          >W
          bu(SW "DPM Ein" "DPM Aus")
          
          Ralla66 1 Reply Last reply Reply Quote 0
          • Ralla66
            Ralla66 Most Active @Wal last edited by Ralla66

            @wal

            ja ok das then wird ausgeführt bei 1 und wenn Switch 0 ist ?

            Wal 1 Reply Last reply Reply Quote 0
            • Wal
              Wal Developer @Ralla66 last edited by

              @ralla66 ,
              SW nimmt den Buttonstatus an und

              chg[SW] >0 heisst change[SW] wenn SW geändert wurde.

              if ((chg[SW]>0)
              then
                vSW=rSW+s(SW)
                sml(1 3 vSW)
              endif
              
              Ralla66 1 Reply Last reply Reply Quote 0
              • Ralla66
                Ralla66 Most Active @Wal last edited by

                @wal

                Script 2 schalten geht, Werte keine

                19:10:26.697 MQT: tele/tasmota_3CECBB/SENSOR = {"Time":"2023-09-17T19:10:26","DC":{"sVolt":0.00,"sCur":0.00,"sSwitch":0,"dVolt":0.00,"vCur":0.00,"tCur":0.0}}
                
                Wal 1 Reply Last reply Reply Quote 0
                • Wal
                  Wal Developer @Ralla66 last edited by

                  @ralla66 ,
                  da haben wir schon ein Problem.

                  Ralla66 1 Reply Last reply Reply Quote 0
                  • Ralla66
                    Ralla66 Most Active @Wal last edited by

                    @wal

                    sollten ankommen

                    Hterm 112.jpg

                    Wal 1 Reply Last reply Reply Quote 0
                    • Wal
                      Wal Developer @Ralla66 last edited by

                      @ralla66 ,
                      ja du hast Recht.
                      Das hier funktioniert also nicht, ist aber nur die Anzeige die macht aber programmtechnisch nichts.

                      >M 1
                      +1,3,m,16,9600,DC,1,2,010300000001,010300010001,010300020001,010310010001,010310020001,010310030001
                      1,010302SSssxxxx@i0:100,Spannung (set),V,sVolt,2
                      1,010302SSssxxxx@i1:1000,Strom (set),A,sCur,2
                      1,010302SSssxxxx@i2:1,Ausgang (set),,sSwitch,0
                      1,010302SSssxxxx@i3:100,Spannung (disp),V,dVolt,2
                      1,010302SSssxxxx@i4:1000,Strom (disp),A,vCur,2
                      1,010302SSssxxxx@i5:1,Temp,°C,tCur,1
                      #
                      
                      Ralla66 1 Reply Last reply Reply Quote 0
                      • Ralla66
                        Ralla66 Most Active @Wal last edited by

                        @wal

                        dann was für später eben.
                        Ein / Aus und Vorgaben Volt und Ampere sollte min lauffähig sein.
                        Bin noch ne Stunde Online wenn du noch was testen möchtest.

                        Erst einmal Danke für die Mühe, Top

                        Ralla

                        1 Reply Last reply Reply Quote 0
                        • Wal
                          Wal Developer last edited by

                          @ralla66 ,
                          das Einzige wäre nur die Anzeige testen.

                          >D
                          >M 1
                          +1,3,m,16,9600,DC,1,2,010300000001,010300010001,010300020001,010310010001,010310020001,010310030001
                          1,010302SSssxxxx@i0:100,Spannung (set),V,sVolt,2
                          1,010302SSssxxxx@i1:1000,Strom (set),A,sCur,2
                          1,010302SSssxxxx@i2:1,Ausgang (set),,sSwitch,0
                          1,010302SSssxxxx@i3:100,Spannung (disp),V,dVolt,2
                          1,010302SSssxxxx@i4:1000,Strom (disp),A,vCur,2
                          1,010302SSssxxxx@i5:1,Temp,°C,tCur,1
                          #
                          
                          Ralla66 1 Reply Last reply Reply Quote 0
                          • Ralla66
                            Ralla66 Most Active @Wal last edited by Ralla66

                            @wal

                            keine Werte in der Web Gui.

                            den Status sw Switch vom DPM kann man weglassen, würde stumpf Ein / Aus senden

                            Nachtrag zum Feierabend :

                            habe and (sw!=SW) entfernt, Ein / Aus geht, Volt und Ampere geht. 🙂 Yeep
                            ( Dein Script von oben )
                            keine Werte in der Web Gui

                            Wal 1 Reply Last reply Reply Quote 1
                            • Wal
                              Wal Developer @Ralla66 last edited by Wal

                              @ralla66 sagte in DMP8624 -> iobroker:

                              habe and (sw!=SW) entfernt, Ein / Aus geht, Volt und Ampere geht.

                              Super, dadurch konnte ich das Skript anpassen und die Verzögerung ist dadurch weg.

                              >D
                              Vmax=60
                              Cmax=24
                              v=0
                              V=0
                              c=0
                              C=0
                              sw=0
                              SW=0
                              rV="01060000"
                              vV=""
                              rC="01060001"
                              vC=""
                              rSW="01060002000"
                              vSW=""
                              >BS
                              +>subscribe V, cmnd/%topic%/tvolt
                              +>subscribe C, cmnd/%topic%/tampere
                              +>subscribe SW, cmnd/%topic%/tpow
                              >B
                              smlj=0
                              ->sensor53 r
                              >R
                              smlj=0
                              >S
                              if upsecs>30
                              then
                              smlj=1
                              endif
                              sw=DC#sSwitch
                              v=DC#sVolt
                              c=DC#sCur
                              if (chg[sw]>0)
                              then
                                SW=sw
                                +>publish stat/%topic%/RESULT {"tpow":%0sw%}
                              endif
                              if ((chg[v]>0) and (V!=v))
                              then
                                V=v
                                +>publish stat/%topic%/RESULT {"tvolt":%2v%}
                              endif
                              if ((chg[c]>0) and (C!=c))
                              then
                                C=c
                                +>publish stat/%topic%/RESULT {"tampere":%2c%}
                              endif
                              if chg[V]>0
                              then
                                if V>Vmax
                                then
                                  V=Vmax
                                endif
                                if V<0
                                then
                                  V=0
                                endif
                                vV=rV+sb(hx((V*100)) 4 4)
                                +>publish stat/%topic%/RESULT {"tvolt":%2V%}
                                sml(1 3 vV)
                              endif
                              if chg[C]>0
                              then
                                if C>Cmax
                                then
                                  C=Cmax
                                endif
                                if C<0
                                then
                                  C=0
                                endif
                                vC=rC+sb(hx((C*1000)) 4 4)
                                +>publish stat/%topic%/RESULT {"tampere":%2C%}
                                sml(1 3 vC)
                              endif
                              if (chg[SW]>0)
                              then
                                vSW=rSW+s(SW)
                                +>publish stat/%topic%/RESULT {"tpow":%0SW%}
                                sml(1 3 vSW)
                              endif
                              >W
                              bu(SW "DPM Ein" "DPM Aus")
                              nm(0.0 60.0 0.01 V "DPM Ausgang (V)" 200 2)
                              nm(0.0 24.0 0.01 C "DPM Ausgang (A)" 200 2)
                              >M 1
                              +1,3,m,16,9600,DC,1,2,010300000001,010300010001,010300020001,010310010001,010310020001,010310030001
                              1,010302SSssxxxx@i0:100,Spannung (set),V,sVolt,2
                              1,010302SSssxxxx@i1:1000,Strom (set),A,sCur,2
                              1,010302SSssxxxx@i2:1,Ausgang (set),,sSwitch,0
                              1,010302SSssxxxx@i3:100,Spannung (disp),V,dVolt,2
                              1,010302SSssxxxx@i4:1000,Strom (disp),A,vCur,2
                              1,010302SSssxxxx@i5:1,Temp,°C,tCur,1
                              #
                              
                              Ralla66 1 Reply Last reply Reply Quote 0
                              • Ralla66
                                Ralla66 Most Active @Wal last edited by

                                @wal

                                🙂 schaltet, V, A geht

                                sw brauchen wir noch damit Status DPM und Web Gui gleich ist.
                                Fast am Ziel ,
                                bin weg für heute 3,2,1 shutdown ----------------------------->

                                Wal 1 Reply Last reply Reply Quote 0
                                • Wal
                                  Wal Developer @Ralla66 last edited by

                                  @ralla66 ,
                                  habe das Skript reduziert, kannst nochmal testen.

                                  >D
                                  Vmax=60
                                  Cmax=24
                                  V=0
                                  C=0
                                  SW=0
                                  rV="01060000"
                                  vV=""
                                  rC="01060001"
                                  vC=""
                                  rSW="01060002000"
                                  vSW=""
                                  sSwitch=0
                                  sVolt=0
                                  sCur=0
                                  >BS
                                  +>subscribe V, cmnd/%topic%/tvolt
                                  +>subscribe C, cmnd/%topic%/tampere
                                  +>subscribe SW, cmnd/%topic%/tpow
                                  >B
                                  ->sensor53 r
                                  tper=10
                                  >S
                                  if chg[SW]>0 {
                                  vSW=rSW+s(SW)
                                  sml(1 3 vSW)
                                  +>publish stat/%topic%/RESULT {"tpow":%0SW%}
                                  }
                                  if chg[V]>0 {
                                  if V>Vmax {
                                  V=Vmax
                                  }
                                  if V<0 {
                                  V=0
                                  }
                                  vV=rV+sb(hx((V*100)) 4 4)
                                  sml(1 3 vV)
                                  +>publish stat/%topic%/RESULT {"tvolt":%2V%}  
                                  }
                                  if chg[C]>0 {
                                  if C>Cmax {
                                  C=Cmax
                                  }
                                  if C<0 {
                                  C=0
                                  }
                                  vC=rC+sb(hx((C*1000)) 4 4) 
                                  sml(1 3 vC)
                                  +>publish stat/%topic%/RESULT {"tampere":%2C%}  
                                  }
                                  >W
                                  bu(SW "DPM Ein" "DPM Aus")
                                  nm(0.0 60.0 0.01 V "DPM Ausgang (V)" 200 2)
                                  nm(0.0 24.0 0.01 C "DPM Ausgang (A)" 200 2)
                                  >M 1
                                  +1,3,m,16,9600,DC,1,2,010300000001,010300010001,010300020001,010310010001,010310020001,010310030001
                                  1,010302SSssxxxx@i0:100,Spannung (set),V,sVolt,2
                                  1,010302SSssxxxx@i1:1000,Strom (set),A,sCur,2
                                  1,010302SSssxxxx@i2:1,Ausgang (set),,sSwitch,0
                                  1,010302SSssxxxx@i3:100,Spannung (disp),V,dVolt,2
                                  1,010302SSssxxxx@i4:1000,Strom (disp),A,vCur,2
                                  1,010302SSssxxxx@i5:1,Temp,°C,tCur,1
                                  #
                                  
                                  Ralla66 1 Reply Last reply Reply Quote 0
                                  • Ralla66
                                    Ralla66 Most Active @Wal last edited by

                                    @wal

                                    schaltet, V, A geht
                                    keine Werte

                                    können wir das Word von SSss per print in der Console ausgeben ?

                                    Wal 2 Replies Last reply Reply Quote 0
                                    • Wal
                                      Wal Developer @Ralla66 last edited by

                                      @ralla66 ,
                                      müsste gehen, ich schau mal.

                                      1 Reply Last reply Reply Quote 0
                                      • Wal
                                        Wal Developer @Ralla66 last edited by

                                        @ralla66 sagte in DMP8624 -> iobroker:

                                        @wal

                                        schaltet, V, A geht
                                        keine Werte

                                        können wir das Word von SSss per print in der Console ausgeben ?

                                        Habe jetzt nichts gefunden.
                                        Man kann nur mit

                                        sensor53 d1
                                        

                                        die Raw Daten anzeigen lassen.

                                        Teste bitte das nochmal, ich habe mal was von einer Beschränkung auf 8 Zeichen gelesen.

                                        >D
                                        Vmax=60
                                        Cmax=24
                                        V=0
                                        C=0
                                        SW=0
                                        rV="01060000"
                                        vV=""
                                        rC="01060001"
                                        vC=""
                                        rSW="01060002000"
                                        vSW=""
                                        >BS
                                        +>subscribe V, cmnd/%topic%/tvolt
                                        +>subscribe C, cmnd/%topic%/tampere
                                        +>subscribe SW, cmnd/%topic%/tpow
                                        >B
                                        ->sensor53 r
                                        tper=10
                                        >S
                                        if chg[SW]>0 {
                                        vSW=rSW+s(SW)
                                        sml(1 3 vSW)
                                        +>publish stat/%topic%/RESULT {"tpow":%0SW%}
                                        }
                                        if chg[V]>0 {
                                        if V>Vmax {
                                        V=Vmax
                                        }
                                        if V<0 {
                                        V=0
                                        }
                                        vV=rV+sb(hx((V*100)) 4 4)
                                        sml(1 3 vV)
                                        +>publish stat/%topic%/RESULT {"tvolt":%2V%}
                                        }
                                        if chg[C]>0 {
                                        if C>Cmax {
                                        C=Cmax
                                        }
                                        if C<0 {
                                        C=0
                                        }
                                        vC=rC+sb(hx((C*1000)) 4 4) 
                                        sml(1 3 vC)
                                        +>publish stat/%topic%/RESULT {"tampere":%2C%}  
                                        }
                                        >W
                                        bu(SW "DPM Ein" "DPM Aus")
                                        nm(0.0 60.0 0.01 V "DPM V" 200 2)
                                        nm(0.0 24.0 0.01 C "DPM A" 200 2)
                                        >M 1
                                        +1,3,m,16,9600,DC,1,2,010300000001,010300010001,010300020001,010310010001,010310020001,010310030001
                                        1,010302SSssxxxx@i0:100,setV,V,sVolt,2
                                        1,010302SSssxxxx@i1:1000,setA,A,sCur,2
                                        1,010302SSssxxxx@i2:1,setP,,sSwitch,0
                                        1,010302SSssxxxx@i3:100,disV,V,dVolt,2
                                        1,010302SSssxxxx@i4:1000,disA,A,vCur,2
                                        1,010302SSssxxxx@i5:1,Temp,°C,tCur,1
                                        #
                                        
                                        Ralla66 1 Reply Last reply Reply Quote 0
                                        • Ralla66
                                          Ralla66 Most Active @Wal last edited by

                                          @wal
                                          keine Änderung,

                                          ESP TX geht ja mit RS485 -> Hterm/DPM bei mir.
                                          Geantwortet wird auch.
                                          Schauen was an RX ankommt per print ?
                                          Was bedeutet das DC hinter der Baud ? for web ui cmd Mqtt Json .
                                          Was bewirkt das.

                                          Wal 2 Replies Last reply Reply Quote 0
                                          • Wal
                                            Wal Developer @Ralla66 last edited by Wal

                                            @ralla66 ,
                                            das ist der Name den man als Platzhalter vergibt, damit man die Empfangenen Daten im Skript nutzen kann.

                                            temp=DC#sVolt
                                            print %temp%
                                            

                                            da wird bei dir aber auch 0 rauskommen wie in der Anzeige.

                                            edit: schau doch mal in die Konsole mit sensor53 d1

                                            Ralla66 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            792
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            7
                                            235
                                            20784
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo