    DMP8624 -> iobroker

    This topic has been deleted. Only users with topic management privileges can see it.
    • Ralla66
      Ralla66 Most Active @Wal last edited by

      @wal

      Habe die Data, %20 weglassen

      18:10:08.057 SCR: performs "WebSend [192.168.2.28] /cm?cmnd=status 10"
      18:10:08.622 MQT: stat/tasmota_3CECBB/RESULT = {"WebQuery":{"StatusSNS":{"Time":"2023-09-20T18:10:08","MT175":{"Geräte_ID":"","Verbrauch_Gesamt":37714,"Bezug_Tarif_1":37714.412,"Bezug_Tarif_2":0,"Netzeinspeisung":0,"Lieferung_Tarif_1":0,"Lieferung_Tarif_2":0,"Bezug_aktuell":9,"Phase_L1":17,"Phase_L2":-71,"Phase_L3":62}}}}
      18:10:08.626 MQT: stat/tasmota_3CECBB/RESULT = {"WebSend":"Done"}
      18:10:08.628 Ralla websend
      
      ; Ralla
      if ((chg[WS]>0) 
      then
      ;10 = show connected sensor information (replaces 'Status 8')
      =>WebSend [192.168.2.28] /cm?cmnd=status 10
      print Ralla websend
      endif
      

      Yeep 🙂
      jetzt noch zerlegen, Ideen ? mit U ?

      Teste mal mit Hichi ob Daten kommen

      Wal 1 Reply Last reply Reply Quote 0
      • Wal
        Wal Developer @Ralla66 last edited by

        @ralla66 ,
        Ätsch war trotzdem erster. 😉

        Ralla66 1 Reply Last reply Reply Quote 0
        • Ralla66
          Ralla66 Most Active @Wal last edited by Ralla66

          @wal

          ok hast gewonnen 🙂

          wie machen wir weiter ?
          Ein DPM Script für alle IR Leseköpfe bauen, also den Status SNS komplett abholen.
          Dann den Bezugswert Filtern. Habe ja kein Hichi. Dieser Wert kann ja anders benannt sein,
          Dann Script cleanen und die erste Beta 1.0 bauen.
          Weiter dann mit der Berechnung Bezug -> DPM setzt V und A ?

          Gruß Ralla

          Nachtrag, Leseköpfe ( Status SNS ) Json einlesen, dann würden auch Shelly PM gehen.

          Wal 1 Reply Last reply Reply Quote 0
          • Wal
            Wal Developer @Ralla66 last edited by Wal

            @ralla66 ,
            ja schau mal ob du den Wert rausfiltern kannst.

            Mit http("192.168.xxx.xxx" "/cm?cmnd=script>Variablename=Wert) kannst du jeder Variable im Script einen Wert verpassen.
            Mit Variable=http("192.168.xxx.xxx" "/cm?cmnd=script?Variablename) kannst du jeden Wert anfordern.

            Ralla66 2 Replies Last reply Reply Quote 0
            • Ralla66
              Ralla66 Most Active @Wal last edited by Ralla66

              @wal

              Ok ich teste mal mit Bezug Aktuell,
              dann brauche ich noch ein Ausgabefenster in der WEB UI mit Wert Bezug Aktuell
              Bzw 2, Bezug Zähler und DPM Ausgang Watt
              Du kannst das schneller 🙂
              Ziel ist ja erreicht, Feierabend ist heute früher.
              Lehrbrief 1, Übung 1 mit Sehr Gut bestanden 😉

              1 Reply Last reply Reply Quote 1
              • Ralla66
                Ralla66 Most Active @Wal last edited by

                @wal

                so ?

                >D
                ; Ralla
                Bezug Aktuell=0
                >T ; alle 10 sec Telemetrieperiode eingestellt
                ; Ralla 
                ; jeder Variable im Script einen Wert zuweisen
                http("192.168.2.28" "/cm?cmnd=script>Bezug Aktuell=Wert)
                print Bezug Aktuell %Bezug Aktuell%
                
                Wal 1 Reply Last reply Reply Quote 0
                • Wal
                  Wal Developer @Ralla66 last edited by Wal

                  @ralla66 ,

                  http("192.168.2.28" "/cm?cmnd=script>Bezug Aktuell=Wert")
                  

                  mit dem Befehl sendest du den Wert an 192.168.2.28.
                  Im 192.168.2.28 muss es eine Variable Bezug Aktuell geben.

                  Ralla66 1 Reply Last reply Reply Quote 0
                  • Ralla66
                    Ralla66 Most Active @Wal last edited by Ralla66

                    @wal

                    ah ja, so ne Art send to
                    dann ist ja das hier vom Zähler ESP holen, jezz is klar 🙂
                    Mit Variable=http("192.168.xxx.xxx" "/cm?cmnd=script?Variablename) kannst du jeden Wert anfordern
                    Ne doch nich, der Pfad im Zähler ESP ist doch StatusSNS->MT175.>Bezug Aktuell->Wert.
                    Ich brauche ne Pause ------------------------->

                    19:43:19.058 MQT: stat/tasmota_3CECBB/RESULT = {"WebQuery":{"StatusSNS":{"Time":"2023-09-20T19:43:16","MT175":{"Geräte_ID":"","Verbrauch_Gesamt":37715,"Bezug_Tarif_1":37714.529,"Bezug_Tarif_2":0,"Netzeinspeisung":0,"Lieferung_Tarif_1":0,"Lieferung_Tarif_2":0,"Bezug_aktuell":93,"Phase_L1":16,"Phase_L2":6,"Phase_L3":70}}}}
                    
                    
                    >D
                    ; Ralla
                    Bezug Aktuell=0
                    
                    ;Mit Variable=http("192.168.xxx.xxx" "/cm?cmnd=script?Variablename) kannst du ;jeden Wert anfordern
                    Bezug Aktuell=http("192.168.2.28" "/cm?cmnd=script?Bezug_Aktuell)
                    print Bezug Aktuell %Bezug Aktuell%
                    
                    Wal 1 Reply Last reply Reply Quote 0
                    • Wal
                      Wal Developer @Ralla66 last edited by

                      @ralla66 ,
                      da musst du machen

                      T
                      aktuell= MT175#Bezug Aktuell

                      Dann kannst du aktuell senden oder anfordern.
                      Schaue in meiner Lösung von der vorherigen Seite.

                      Ralla66 1 Reply Last reply Reply Quote 0
                      • Ralla66
                        Ralla66 Most Active @Wal last edited by Ralla66

                        @wal

                        ok, Danke, heute nicht mehr.
                        Sackt langsam, das ist im Zähler ESP.
                        Das war bei mir nicht geplant, immer schwierig für Beginner wenn auf der Tasmota Seite
                        das SML angepasst werden muß. Einfacher wäre es nur in der DPM Script Var Deklaration
                        ein Paar Werte einzugeben. Das ist ja für mich schon sehr schwer.

                        Ralla66 1 Reply Last reply Reply Quote 0
                        • Ralla66
                          Ralla66 Most Active @Ralla66 last edited by

                          @ralla66

                          Nachtrag:

                          Werde das wohl so bauen,
                          Ein / Aus für Wartungsarbeiten
                          Automatic Ein ist Nulleinspeisung
                          Automatic Aus Handvorgaben zum Testen des Wirkungsgrades
                          Button Timer Ein / Aus noch einfügen für vorgegebene Timerzeiten aus dem
                          Script Bsp: 19:00 - 6:00, Internen Tasmota Timer nutzen
                          Mqtt alle StatusSNS Werte nach IO

                          DPM Soll.jpg

                          Wal 1 Reply Last reply Reply Quote 0
                          • Wal
                            Wal Developer @Ralla66 last edited by Wal

                            @ralla66 ,
                            habe es jetzt geschafft ohne Änderung des Stromzähler Scripts.
                            Es muss aber wieder was in die Firmware eingefügt werden.
                            Habe das jetzt alles drin:

                            #define USE_SCRIPT_WEB_DISPLAY
                            #define USE_WEBSEND_RESPONSE
                            #define USE_SCRIPT_STATUS
                            #define USE_SCRIPT_FULL_JSON_PARSER
                            #define USE_SCRIPT
                            #define SUPPORT_MQTT_EVENT
                            #define USE_SML_M
                            #define USE_SML_SCRIPT_CMD
                            
                            >D
                            Timer=0
                            pwr=0
                            Vmax=60
                            Cmax=24
                            V=0
                            C=0
                            SW=0
                            rV="01060000"
                            vV=""
                            rC="01060001"
                            vC=""
                            rSW="01060002000"
                            vSW=""
                            >BS
                            +>subscribe V, cmnd/%topic%/tvolt
                            +>subscribe C, cmnd/%topic%/tampere
                            +>subscribe SW, cmnd/%topic%/tpow
                            >B
                            ->sensor53 r
                            tper=10
                            >S
                            Timer+=1
                            if Timer>10 {
                            =>websend [192.168.xxx.xxx] /cm?cmnd=status 10
                            Timer=0
                            }
                            if chg[SW]>0 {
                            vSW=rSW+s(SW)
                            sml(1 3 vSW)
                            +>publish stat/%topic%/RESULT {"tpow":%0SW%}
                            }
                            if chg[V]>0 {
                            if V>Vmax {
                            V=Vmax
                            }
                            if V<0 {
                            V=0
                            }
                            vV=rV+sb(hx((V*100)) 4 4)
                            sml(1 3 vV)
                            +>publish stat/%topic%/RESULT {"tvolt":%2V%}  
                            }
                            if chg[C]>0 {
                            if C>Cmax {
                            C=Cmax
                            }
                            if C<0 {
                            C=0
                            }
                            vC=rC+sb(hx((C*1000)) 4 4) 
                            sml(1 3 vC)
                            +>publish stat/%topic%/RESULT {"tampere":%2C%}  
                            }
                            >E
                            pwr=WebQuery#StatusSNS#MT175#P
                            >W
                            bu(SW "DPM Ein" "DPM Aus")
                            nm(0.0 60.0 0.01 V "DPM Ausgang (V)" 200 2)
                            nm(0.0 24.0 0.01 C "DPM Ausgang (A)" 200 2)
                            Aktuelle Leistung{m} %0pwr% W
                            >M 1
                            +1,3,m,16,9600,DC,1,2,010300000001,010300010001,010300020001,010310030001
                            1,010302SSssxxxx@i0:100,Spannung,V,sVolt,2
                            1,010302SSssxxxx@i1:1000,Strom,A,sCur,2
                            1,010302SSssxxxx@i2:1,Ausgang,,sSwitch,0
                            1,010302SSssxxxx@i3:1,Temp,°C,tCur,1
                            #
                            

                            E ;hier das json parsen

                            Ralla66 Jonas Haber 2 Replies Last reply Reply Quote 0
                            • Ralla66
                              Ralla66 Most Active @Wal last edited by

                              @wal
                              ja cool, werde ich am Wochenende testen.
                              Werde mal schauen was am Compiler bei mir nicht stimmt.
                              Weisst du ob er Timer mit der Tagesvorwahl in Tasmota Standart mit drin ist.
                              Hatte noch keine Zeit das prüfen.
                              Bin am vorbereiten, da morgen der Dachdecker noch 4 Module anbringt. 🙂

                              Wal 1 Reply Last reply Reply Quote 0
                              • Wal
                                Wal Developer @Ralla66 last edited by

                                @ralla66 ,
                                bei mir nicht, müsste ich erst hinzufügen.

                                Ralla66 1 Reply Last reply Reply Quote 0
                                • Ralla66
                                  Ralla66 Most Active @Wal last edited by Ralla66

                                  @wal

                                  Habe immer Warning Fehler auf Git. Das nervt als Beginner.
                                  Erst recht wenn man keine Ahnung hat.

                                  git 1.jpg

                                  Wal 1 Reply Last reply Reply Quote 0
                                  • Wal
                                    Wal Developer @Ralla66 last edited by

                                    @ralla66 ,
                                    habe wieder was.
                                    Globale Variable
                                    Man braucht kein websend es funktioniert einfach so.

                                    Ralla66 1 Reply Last reply Reply Quote 0
                                    • Ralla66
                                      Ralla66 Most Active @Wal last edited by Ralla66

                                      @wal

                                      Morgen, läuft nun, wir sollen mal eine Versionnummer vergeben.wal 2209.jpg

                                      Jetzt die Verkasperung, wenn Bezug Watt ist x steuere V und A mit 🙂
                                      Natürlich gepart mit Triggerudatezeit.
                                      Schöner Wohnen machen wir am Scluss, sollte erst laufen.

                                      Nachtrag

                                      für eine Nachteinspeisung sollten wir einen Button anlegen Timer aktiv.
                                      Wichtige Parameter wie Bezug Zähler und berechnete Ausgangsleistung BAL gehören auch dazu.
                                      So wird auch sofort erkannt ob der Zähler ESP läuft und ob das Script läuft.
                                      DC Ausgang und Temp sind ja eher Schöner Wohnen.

                                      Dpm Timer.jpg

                                      Für die Berechnung Bezug -> Ausgang könnte man die Daten eines HM 600
                                      nehmen, linear dürfte reichen. Betrieb des HM etc unter 50 Watt ist eher Sinn befreit.
                                      Die Daten V und A eines HM könnte ich Live mitloggen wenn Sonne da ist.

                                      DPM Dtu.jpg

                                      DPM Soll 1111.jpg

                                      Wal 1 Reply Last reply Reply Quote 0
                                      • Wal
                                        Wal Developer @Ralla66 last edited by

                                        @ralla66 ,
                                        da habe ich im Moment die Hardware dazu zum testen. Du musst aber den Skriptspeicher im Auge behalten oder auf einen ESP32 wechseln. Berryscript sollte ich mir auch mal anschauen.

                                        Ralla66 1 Reply Last reply Reply Quote 0
                                        • Ralla66
                                          Ralla66 Most Active @Wal last edited by Ralla66

                                          @wal

                                          bestelle schon mal Esp32 falls das zu wenig ist.
                                          1366 Zeichen sind übrig.
                                          Im Script fehlt ja nur noch Wert Bezug extrahieren und die Berechnung.
                                          Denke wird bsp. -> 150 Watt Bezug : Volt Festwert 29 Volt = A <-

                                          Der Pylontech hat immer zwischen 47 und 52 Volt .
                                          Schaue heute abend mal die Livedaten ab 19:00 Uhr.

                                          erster Eindruck, Hoymiles DC eine Seite,

                                          DPM Messung 1.jpg

                                          Nachtrag, man könnte auch den Mppt des WR setzen zwischen 25 und 32 Volt, 0 -12 A .
                                          Dazu müsste der Mppt Point bekannt sein oder eine Var anlegen das jeder Fest Volt
                                          selbst bestimmt.
                                          Der Lumentree hat meist bsp. -> 150 Watt Bezug : Volt Festwert 49 Volt Pylon = A <-
                                          Na ja, Pylontech Spannungswert einlesen ist ja jetzt easy.

                                          DPM SP.jpg

                                          Wal 1 Reply Last reply Reply Quote 1
                                          • Wal
                                            Wal Developer @Ralla66 last edited by Wal

                                            @ralla66 ,
                                            ja das wollte ich so umsetzen, feste Spannung am WR und Ampere regeln.
                                            Nach dem Einschalten des DPM die Spannung langsam hochfahren auf z.B. 30V und danach je nach Leistungsabnahme den Strom regeln.

                                            Edit: ich nutze ein APSystems DS3-S den kann man noch nicht regeln.

                                            Ralla66 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            798
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            7
                                            235
                                            20777