    4. Gelöst Modbus import TSV -> No field isScale in position 15

    NEWS

    • Neuer Blog: Fotos und Eindrücke aus Solingen

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    Gelöst Modbus import TSV -> No field isScale in position 15

    This topic has been deleted. Only users with topic management privileges can see it.
    • Glasfaser
      Glasfaser @wendy2702 last edited by

      @wendy2702

      Ist der Fehler immer noch bei dir !?

      wendy2702 1 Reply Last reply Reply Quote 0
      • wendy2702
        wendy2702 @Glasfaser last edited by

        @glasfaser Ja.

        Gerade mal ne neue Instanz hinzugefügt. Gleicher Fehler.

        Glasfaser 1 Reply Last reply Reply Quote 0
        • Glasfaser
          Glasfaser @wendy2702 last edited by Glasfaser

          @wendy2702

          Test nur mit einem Registereintrag !?

          9851988e-3250-42a0-9d13-4a43eaa10f99-grafik.png

          wendy2702 1 Reply Last reply Reply Quote 0
          • wendy2702
            wendy2702 @Glasfaser last edited by wendy2702

            @glasfaser Habe ich auch schon probiert:

            3138ba75-b7c7-4e93-a7ba-32164eb9bde2-grafik.png

            Geht bei mir auch nicht

            Habe die jetzt mal manuell eingetragen. Dann exportiert und versucht in eine neue Instanz zu importieren. Geht auch nicht.

            Keine Ahnung woran das liegt.

            Glasfaser 1 Reply Last reply Reply Quote 0
            • Glasfaser
              Glasfaser @wendy2702 last edited by Glasfaser

              @wendy2702

              Da stimmt was nicht bei dir , wenn ich mir die Zuweisungsnamen in deinem Screenshot anschaue .

              Bei dir endet es bei isScale_address, das gibt es nicht in Modbus

              Es sieht so aus als hättest du den Anfang doppet drin :

              b1e5a020-e5fa-4537-b179-feeaba2215cb-grafik.png

              so ist es richtig , es endet bei scale ,

              5d412110-fa48-4139-bd7c-80e373f02f64-grafik.png
              .
              .

              Gegenfrage , hast du mal ein anderes Register genutzt oder testet du immer mit dem gleichen !?

              hier im Thread sind auch andere , die kannst du auch zum testen nehmen

              https://forum.iobroker.net/topic/44510/aufruf-sammlung-an-modbus-anbindungen

              1 Reply Last reply Reply Quote 0
              • wendy2702
                wendy2702 last edited by

                @glasfaser Das war der Hinweis!

                Eigentlich ein "Bug" wenn man mich fragt.

                Folgendes passiert ja wenn ich auf den "Export/Import" Button klicke:

                neues Fenster mit registern geht auf
                man klickt auf "In die Zwischenablage Kopieren"

                Das Beinhaltet dann alles was im Fenster steht, so auch die Zeile "0" mit den Überschriften.

                In der neuen Instanz öffnet man wieder das "Export/Import" Fenster, fügt alles ein und hat dadurch die Zeile "0" quasi zweimal hintereinander drin.

                Export_import_NOK.gif

                Wenn es kein Bug ist wäre zumindest ein Hinweis angebracht das Zeile "0" vor dem Import gelöscht werden muss.

                Glasfaser 1 Reply Last reply Reply Quote 1
                • Glasfaser
                  Glasfaser @wendy2702 last edited by Glasfaser

                  @wendy2702

                  dann müßte eine Prüfvariable rein , wenn kein Register vorhanden , dann leeres Fenster öffnen .

                  Mhh .. ist mir noch nie passiert , da ich immer alles einfüge / überschreibe

                  wendy2702 1 Reply Last reply Reply Quote 0
                  • wendy2702
                    wendy2702 @Glasfaser last edited by

                    @glasfaser Das heisst beim Import markierst du die bereits existierende Zeile und überschreibst die dann.

                    Klar ist das der oder ein Weg. Wenn ich aber, wie jetzt vor lauter übereifer in meinem Fall auch an unbedachte, unerfahrene User denke wundert mich das es noch keinem Aufgefallen ist.

                    Wenn ich aber der einzige depp bin dem das passiert ist belassen wir es einfach dabei.

                    Glasfaser 1 Reply Last reply Reply Quote 0
                    • Glasfaser
                      Glasfaser @wendy2702 last edited by

                      @wendy2702 sagte in Modbus import TSV error --> No field isScale in position 15:

                      Das heisst beim Import markierst du die bereits existierende Zeile und überschreibst die dann.

                      richtig ... schon immer so gemacht

                      unerfahrene User

                      da hast du recht ... sollte man trotzdem eventuell als Issues anfragen !?

                      Wenn ich aber der einzige depp bin dem das passiert ist belassen wir es einfach dabei.

                      Kein Kommentar 😉

                      1 Reply Last reply Reply Quote 0
                      • I
                        ici-ice last edited by ici-ice

                        @glasfaser: das Thema ist schon vom Januar, jedoch möchte ich hier noch einmal einhaken, weil ich exakt das gleiche Problem habe und ich auf keine Lösung komme, egal welche Variante ich ausprobiere.
                        Gerade habe ich den Modbus Adapter installiert, um ihn mit meinem Sungrow WR zu verbinden.
                        Die Einstellungen unter "Allgemein" habe ich so übernommen, wie oben beschrieben. Beim Importieren der TSV-Daten bekomme ich folgenden Fehler:
                        Fehler Import.PNG
                        das TSV-File habe ich hier downgeloaded:
                        https://forum.iobroker.net/topic/38441/sungrow-wr-sgh10rt-erfolgreich-mit-modbus-eingebunden/3
                        Hat jemand eine Idee, warum der Import nicht klappt?

                        Glasfaser 1 Reply Last reply Reply Quote 0
                        • Glasfaser
                          Glasfaser @ici-ice last edited by

                          @ici-ice sagte in Gelöst Modbus import TSV -> No field isScale in position 15:

                          Hat jemand eine Idee, warum der Import nicht klappt?

                          ja ,
                          weil sich die Modus Formatierung geändert hat , dein Vorlage ist aus 2020 , die muß dann angepasst werden .

                          Hier habe ich es angepasst :
                          .

                          _address	name	description	unit	type	len	factor	offset	formula	role	room	poll	wp	cw	isScale
                          4999	System Clock Year	Systemzeit Jahr		uint16be	1	1	0		value		true	false	false	false
                          5000	System Clock Month	Systemzeit Monat		uint16be	1	1	0		value		true	false	false	false
                          5001	System Clock Day	Systemzeit Tag		uint16be	1	1	0		value		true	false	false	false
                          5002	System Clock Hour	Systemzeit Stunde		uint16be	1	1	0		value		true	false	false	false
                          5003	System Clock Minute	Systemzeit Minute		uint16be	1	1	0		value		true	false	false	false
                          12999	Start/Stop	Start/Stop Start(CF) Stop (CF)		uint16be	1	1	0		value		true	false	false	false
                          13001	Load Adjustment mode	Energie Management Modus ON/OFF(1) / Energieoptimiert(2)		uint16be	1	1	0		value		true	false	false	false
                          13002	Load 1 timing period 1: Start hour		h	uint16be	1	1	0		value		true	false	false	false
                          13003	Load 1 timing period 1: Start minute		min	uint16be	1	1	0		value		true	false	false	false
                          13004	Load 1 timing period 1: End hour		min	uint16be	1	1	0		value		true	false	false	false
                          13005	Load 1 timing period 1: End minute		h	uint16be	1	1	0		value		true	false	false	false
                          13006	Load 1 timing period 2: Start hour		h	uint16be	1	1	0		value		true	false	false	false
                          13007	Load 1 timing period 2: Start minute		min	uint16be	1	1	0		value		true	false	false	false
                          13008	Load 1 timing period 2: End hour		h	uint16be	1	1	0		value		true	false	false	false
                          13009	Load 1 timing period 2: End minute		min	uint16be	1	1	0		value		true	false	false	false
                          13010	Load 1 ON/OFF mode	Load 1 ON/OFF mode    ON(170/AA)/ OFF (85/55)		uint16be	1	1	0		value		true	false	false	false
                          13011	Load 1 power optimized mode: Start hour		h	uint16be	1	1	0		value		true	false	false	false
                          13012	Load 1 power optimized mode: Start minute		min	uint16be	1	1	0		value		true	false	false	false
                          13013	Load 1 power optimized mode: End hour		h	uint16be	1	1	0		value		true	false	false	false
                          13014	Load 1 power optimized mode: End Minute 		min	uint16be	1	1	0		value		true	false	false	false
                          13015	Optimized power of load 1	Optimized power of load 1	W	uint16be	1	1	0		value		true	false	false	false
                          13049	EMS mode selection 	EMS Modus		uint16be	1	1	0		value		true	false	false	false
                          13050	Charge/discharge command	Ext. Sollvorgabe Laden170(AA)/ Stop187(BB)/ Entladen204(CC) 		uint16be	1	1	0		value		true	false	false	false
                          13051	Charge/discharge power	Ext. Sollvorgabe Lade/Entladeleistung		uint16be	1	1	0		value		true	false	false	false
                          13055	Batterie nominal Voltage	Nominal Spannung Batterie	V	uint16be	1	0.1	0		value		true	false	false	false
                          13056	Battery capacity	Batteriekapazität	Ah	uint16be	1	1	0		value		true	false	false	false
                          13057	Max. SOC	Max SOC	%	uint16be	1	0.1	0		value		true	false	false	false
                          13058	Min. SOC	Min SOC	%	uint16be	1	0.1	0		value		true	false	false	false
                          13059	Battery overvoltage threshold	Batterie Überspannungs Threshold	V	int16be	1	0.1	0		value		true	false	false	false
                          13060	Battery undervoltage threshold	Batterie Unterspannungs Threshold	V	int16be	1	0.1	0		value		true	false	false	false
                          13061	Battery over temperature threshold	Batterie Übertemperatur Threshold	°C	int16be	1	0.1	0		value		true	false	false	false
                          13062	Battery under temperature threshold	Batterie Übertemperatur Threshold	°C	int16be	1	0.1	0		value		true	false	false	false
                          13064	Terminated current of constant voltage charging		°C	int16be	1	0.001	0		value		true	false	false	false
                          13065	Max. discharge current	Max. Entlade Strom	A	uint16be	1	0.001	0		value		true	false	false	false
                          13066	Max. charge current	Max. Lade Strom	A	uint16be	1	0.001	0		value		true	false	false	false
                          13079	External EMS heartbeat			uint16be	1	1	0		value		true	false	false	false
                          13083	Start  Charging Power	u.U. Leistung, mit welcher ein Ladevorgang begonnen wird. Klärung erwünscht	W	uint16be	1	1	0		value		true	false	false	false
                          13084	Start Discharging Power	u.U. Leistung, mit welcher ein Entladevorgang begonnen wird. Klärung erwünscht	W	uint16be	1	1	0		value		false	false	false	false
                          13085	Meter Comm.	Kommunikation mit Energie Meter des WR	W	uint16be	1	1	0		value		true	false	false	false
                          13086	Export Power Limitation	Einspeise Limitierung AN(170/AA) AUS(85/55h)		uint16be	1	1	0		value		true	false	false	false
                          13099	SOC Reserve	SOC Reserve	%	uint16be	1	1	0		value		true	false	false	false
                          

                          I 1 Reply Last reply Reply Quote 0
                          • I
                            ici-ice @Glasfaser last edited by ici-ice

                            @glasfaser said in Gelöst Modbus import TSV -> No field isScale in position 15:

                            _address name description unit type len factor offset formula role room poll wp cw isScale

                            schon mal vielen Dank für deine Unterstützung aber ich bin wahrscheinlich zu doof für den Import. Ich habe deine Daten kopiert, in den Editor geladen, Leerzeilen gelöscht, dann kopiert und zum Import eingefügt.
                            Es kommen folgende Fehler:
                            Fehler Import.PNG
                            Irgendwas mache ich noch falsch

                            Edit: muss die Modbus-Verbindung zum Sungrow WR bereits funktionieren oder spielt das beim Import der Registerdaten keine Rolle?

                            Glasfaser 1 Reply Last reply Reply Quote 0
                            • Glasfaser
                              Glasfaser @ici-ice last edited by

                              @ici-ice sagte in Gelöst Modbus import TSV -> No field isScale in position 15:

                              Irgendwas mache ich noch falsch

                              das kommt im Holding Register !

                              I 1 Reply Last reply Reply Quote 0
                              • I
                                ici-ice @Glasfaser last edited by

                                @glasfaser : Guten Morgen, bei Einfügen der Daten ins Holding Register kommen die gleichen Fehlermeldungen 😧

                                Glasfaser 1 Reply Last reply Reply Quote 0
                                • Glasfaser
                                  Glasfaser @ici-ice last edited by

                                  @ici-ice sagte in Gelöst Modbus import TSV -> No field isScale in position 15:

                                  kommen die gleichen Fehlermeldungen

                                  Immer ein Screenshot davon , das sagt mehr aus !

                                  Ich vermute das es mit einem Zeilenumbruch kopiert/importiert wird ( passiert bei Firefox ) .

                                  Achte auch auf die Verbindungsparameter , Keine Geräte ID !

                                  siehe so , die Vorlage funktioniert :
                                  .
                                  Animation.gif

                                  I 1 Reply Last reply Reply Quote 0
                                  • I
                                    ici-ice @Glasfaser last edited by

                                    @glasfaser : jetzt läufts! Bin ja so happy, vielen Dank!! Bin jetzt mit dem Chrome Browser rein und hab damit kopiert - hat auf Anhieb geklappt. Beim Firefox habe ich vorher tatsächlich viele Leerzeilen rauswerfen müssen. Vermutlich hat sich beim Formatieren ein Fehler eingeschlichen.
                                    Noch mal: vielen Dank!

                                    Glasfaser 1 Reply Last reply Reply Quote 0
                                    • Glasfaser
                                      Glasfaser @ici-ice last edited by

                                      @ici-ice sagte in Gelöst Modbus import TSV -> No field isScale in position 15:

                                      Noch mal: vielen Dank!

                                      ... sehr gerne .. 😉

                                      I 1 Reply Last reply Reply Quote 0
                                      • I
                                        ici-ice @Glasfaser last edited by

                                        @glasfaser : noch eine Frage: hast du aktuelle Daten, mit denen ich auch das Eingangsregister füllen kann?

                                        1 Reply Last reply Reply Quote 0
                                        • First post
                                          Last post

                                        Support us

                                        ioBroker
                                        Community Adapters
                                        Donate

                                        783
                                        Online

                                        31.9k
                                        Users

                                        80.1k
                                        Topics

                                        1.3m
                                        Posts

                                        3
                                        23
                                        1392
                                        Loading More Posts
                                        • Oldest to Newest
                                        • Newest to Oldest
                                        • Most Votes
                                        Reply
                                        • Reply as topic
                                        Log in to reply
                                        Community
                                        Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                        The ioBroker Community 2014-2023
                                        logo