Navigation

    Logo
    • Register
    • Login
    • Search
    • Recent
    • Tags
    • Unread
    • Categories
    • Unreplied
    • Popular
    • GitHub
    • Docu
    • Hilfe
    1. Home
    2. Deutsch
    3. Off Topic
    4. Microcontroller
    5. Tasmota ESPHome Presence Sensor LD2410

    NEWS

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    • Monatsrückblick - April 2025

    Tasmota ESPHome Presence Sensor LD2410

    This topic has been deleted. Only users with topic management privileges can see it.
    • S
      smarthome2020 @Ralla66 last edited by

      @ralla66
      Ja, da geht der AP dann ja.

      Ralla66 1 Reply Last reply Reply Quote 0
      • Ralla66
        Ralla66 Most Active @smarthome2020 last edited by Ralla66

        @smarthome2020

        die release gehen auch ?
        Speicher vor dem flashen löscht du immer ?

        S 1 Reply Last reply Reply Quote 0
        • S
          smarthome2020 @Ralla66 last edited by

          @ralla66
          Ja, habe nun noch ein anderes Flash-Tool gezogen. Damit scheint der Flashvorgang zu gehen.
          Nun hapert es noch an meiner kompilierten Bin. Deine Bin geht auch hier leider nicht.

          Ralla66 1 Reply Last reply Reply Quote 0
          • Ralla66
            Ralla66 Most Active @smarthome2020 last edited by Ralla66

            @smarthome2020

            wenn das mit Tasmocompiler sauber erzeugt ist, meine am Ende kommt code 0 für ok
            dann ist die .bin in Ordnung.
            Am ESP ist nichts angeschlossen ?

            S 1 Reply Last reply Reply Quote 0
            • S
              smarthome2020 @Ralla66 last edited by

              @ralla66

              ESP geht nun soweit. Hab nun in den Konfigurationen folgende GPIOs ausgewählt.
              BSP.png
              Dein Skript ist auch eingefügt. Leider gibt es keine Werte.

              Ralla66 1 Reply Last reply Reply Quote 0
              • Ralla66
                Ralla66 Most Active @smarthome2020 last edited by Ralla66

                @smarthome2020

                du kannst nicht jeden beliebigen GPIO nehmen musste testen.
                Script ist eingefügt und aktiviert ?

                S 1 Reply Last reply Reply Quote 0
                • S
                  smarthome2020 @Ralla66 last edited by smarthome2020

                  @ralla66
                  Danke 🙂 Du hast meine Nacht gerettet 😄
                  Meine Güte. Wieso ich aber nun nicht mit den sonst üblichen Tools etwas flashen kann... Weiß ich nicht.

                  Den Presence-Wert habe ich aber nicht. Bei mir sieht es so aus:
                  BSP.png

                  Ralla66 1 Reply Last reply Reply Quote 0
                  • Ralla66
                    Ralla66 Most Active @smarthome2020 last edited by Ralla66

                    @smarthome2020

                    Glückwunsch, Prima, läuft ja fast. 🙂
                    Schau mal wo an deinem ESP der Analog 0 angeschlossen werden kann.
                    Nicht jeder GPIO kann Analogwerte einlesen.
                    Teste mal GPIO 32

                    S 1 Reply Last reply Reply Quote 0
                    • S
                      smarthome2020 @Ralla66 last edited by

                      @ralla66
                      GPIO32 und dann ADC-Eingang da drauflegen?
                      Wenn ja, dann kommt bei mir ein Zahlenwert um die 4000.

                      Ralla66 1 Reply Last reply Reply Quote 0
                      • Ralla66
                        Ralla66 Most Active @smarthome2020 last edited by

                        @smarthome2020

                        ja richtig, ist so ok

                        S 1 Reply Last reply Reply Quote 0
                        • S
                          smarthome2020 @Ralla66 last edited by

                          @ralla66
                          Und wie sagt mit der Wert 4000 nun Präsenz an?

                          Ralla66 1 Reply Last reply Reply Quote 0
                          • Ralla66
                            Ralla66 Most Active @smarthome2020 last edited by

                            @smarthome2020

                            das ist ein Spannungswert umgerechnet.
                            Bei 3,3 Volt am Pin ist der Wert 4096.
                            Wenn am GPIO 32 das Kabel ab ist müsste es 0 anzeigen.

                            S 1 Reply Last reply Reply Quote 0
                            • S
                              smarthome2020 @Ralla66 last edited by smarthome2020

                              @ralla66
                              Laut Skript soll der Wert an GPIO32 auch ausgewertet werden mit einem Cutoff von 500. Bei mir wird in der Anzeige aber nichts von Presence angezeigt. Auch per MQTT ist im ioBroker nichts zu finden.

                              P.S.: Wenn ich das Kabel abziehe an GPIO32, bleibt der Wert bei 4000!

                              Ralla66 1 Reply Last reply Reply Quote 0
                              • Ralla66
                                Ralla66 Most Active @smarthome2020 last edited by Ralla66

                                @smarthome2020

                                Script ist aktiviert ?
                                500 ist der Grenzwert
                                < > ist Presence ON OFF
                                Nachtrag:
                                IO Mqtt wird erst nach einem Reboot des Esp Subscribt

                                S 1 Reply Last reply Reply Quote 0
                                • S
                                  smarthome2020 @Ralla66 last edited by

                                  @ralla66

                                  Bei GPIO34 ist es bei mir so, dass bei angestecktem Kabel der Wert bei 4000 liegt, abgezogen dann bei 0.
                                  Habe das Skript wie folgt geändert, es kommt jedoch kein Presence dazu.

                                  >D
                                   
                                  Timer=0
                                  ;Text ON oder OFF
                                  EA=""
                                  ;Wert Analog
                                  WA=0
                                  ;Presence
                                  PRE=0
                                   
                                   
                                  >BS
                                   
                                  +>subscribe EA, cmnd/%topic%/Presence
                                   
                                  >S
                                   
                                  Timer+=1
                                  if Timer>5
                                   
                                   
                                  print ADC 10.10 %adc(1 34)%
                                   
                                  if adc(1 34)>501
                                  then
                                  EA="OFF"
                                  PRE=0
                                  +>publish stat/%topic%/RESULT {"Presence":%0PRE%}
                                  print TEXT ON %EA%
                                  print Wert ON %WA%
                                  print Presence %PRE%
                                  endif
                                   
                                  if adc(1 34)<500
                                  then
                                  +>publish stat/%topic%/RESULT {"Presence":%0PRE%}
                                  EA="ON"
                                  PRE=1
                                  print TEXT OFF %EA%
                                  print Wert OFF %WA%
                                  print Presence %PRE%
                                  endif
                                   
                                   
                                  Timer=0
                                   
                                   
                                  >W
                                  LD2410 Presence{m} %EA% 
                                  
                                  #
                                  
                                  Ralla66 2 Replies Last reply Reply Quote 0
                                  • Ralla66
                                    Ralla66 Most Active @smarthome2020 last edited by Ralla66

                                    @smarthome2020

                                    schau auf der Main Seite bei Tasmota nach.
                                    dies soll LD2410 Presence mit Wert auf der Main Seite anzeigen.

                                    W
                                    LD2410 Presence{m} %EA%

                                    wenn nicht fehlt in der .bin use Web .......

                                    1 Reply Last reply Reply Quote 0
                                    • Ralla66
                                      Ralla66 Most Active @smarthome2020 last edited by Ralla66

                                      @smarthome2020

                                      das hier :

                                      W
                                      The lines in this section are displayed in the web UI main page. Requires compiling with #define USE_SCRIPT_WEB_DISPLAY.

                                      Nachtrag, den GPIO A0 Wert Main kannste testen mit 3,3 V vom ESP nach GPIO.
                                      Schau mal in der Doku LD nach, meine 3,3 V ist Presence.

                                      S Wal 2 Replies Last reply Reply Quote 0
                                      • S
                                        smarthome2020 @Ralla66 last edited by

                                        @ralla66
                                        Wo hast du die Infos her?

                                        Die Presence Anzeige ist nun da. Im Skript ist bei > 500 aber auf Off gestellt und bei <500 auf on. Muss dsa nicht andersherum sein?

                                        Ralla66 1 Reply Last reply Reply Quote 0
                                        • Ralla66
                                          Ralla66 Most Active @smarthome2020 last edited by Ralla66

                                          @smarthome2020

                                          Info Scripting
                                          und Beitrag vom 8. Okt. 2023, 15:14

                                          <> On / OFF ist ja vom Sensor und dem ESP abhängig.
                                          Es gibt auch Bewegungsmelder dort ist das anders herum.
                                          Die 500 dient ja nur dazu kleine Spannungsschwankungen auf der Leitung
                                          auszublenden. Kannste auch auf 2000 stellen.
                                          Könntest auch mit Pull Down / UP arbeiten, eben mehr Hardware.

                                          S 1 Reply Last reply Reply Quote 0
                                          • S
                                            smarthome2020 @Ralla66 last edited by

                                            @ralla66
                                            Funktioniert nun passabel. Nun brauche ich nur noch ein Case . Danke nochmal für deine Hilfe. Funktioniert nun viel besser als mit ESpHome

                                            Ralla66 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            1.0k
                                            Online

                                            31.7k
                                            Users

                                            79.7k
                                            Topics

                                            1.3m
                                            Posts

                                            17
                                            187
                                            27958
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo