    • Ralla66
      Ralla66 Most Active @smarthome2020 last edited by Ralla66

      @smarthome2020

      Glückwunsch, Prima, läuft ja fast. 🙂
      Schau mal wo an deinem ESP der Analog 0 angeschlossen werden kann.
      Nicht jeder GPIO kann Analogwerte einlesen.
      Teste mal GPIO 32

      S 1 Reply Last reply Reply Quote 0
      • S
        smarthome2020 @Ralla66 last edited by

        @ralla66
        GPIO32 und dann ADC-Eingang da drauflegen?
        Wenn ja, dann kommt bei mir ein Zahlenwert um die 4000.

        Ralla66 1 Reply Last reply Reply Quote 0
        • Ralla66
          Ralla66 Most Active @smarthome2020 last edited by

          @smarthome2020

          ja richtig, ist so ok

          S 1 Reply Last reply Reply Quote 0
          • S
            smarthome2020 @Ralla66 last edited by

            @ralla66
            Und wie sagt mit der Wert 4000 nun Präsenz an?

            Ralla66 1 Reply Last reply Reply Quote 0
            • Ralla66
              Ralla66 Most Active @smarthome2020 last edited by

              @smarthome2020

              das ist ein Spannungswert umgerechnet.
              Bei 3,3 Volt am Pin ist der Wert 4096.
              Wenn am GPIO 32 das Kabel ab ist müsste es 0 anzeigen.

              S 1 Reply Last reply Reply Quote 0
              • S
                smarthome2020 @Ralla66 last edited by smarthome2020

                @ralla66
                Laut Skript soll der Wert an GPIO32 auch ausgewertet werden mit einem Cutoff von 500. Bei mir wird in der Anzeige aber nichts von Presence angezeigt. Auch per MQTT ist im ioBroker nichts zu finden.

                P.S.: Wenn ich das Kabel abziehe an GPIO32, bleibt der Wert bei 4000!

                Ralla66 1 Reply Last reply Reply Quote 0
                • Ralla66
                  Ralla66 Most Active @smarthome2020 last edited by Ralla66

                  @smarthome2020

                  Script ist aktiviert ?
                  500 ist der Grenzwert
                  < > ist Presence ON OFF
                  Nachtrag:
                  IO Mqtt wird erst nach einem Reboot des Esp Subscribt

                  S 1 Reply Last reply Reply Quote 0
                  • S
                    smarthome2020 @Ralla66 last edited by

                    @ralla66

                    Bei GPIO34 ist es bei mir so, dass bei angestecktem Kabel der Wert bei 4000 liegt, abgezogen dann bei 0.
                    Habe das Skript wie folgt geändert, es kommt jedoch kein Presence dazu.

                    >D
                     
                    Timer=0
                    ;Text ON oder OFF
                    EA=""
                    ;Wert Analog
                    WA=0
                    ;Presence
                    PRE=0
                     
                     
                    >BS
                     
                    +>subscribe EA, cmnd/%topic%/Presence
                     
                    >S
                     
                    Timer+=1
                    if Timer>5
                     
                     
                    print ADC 10.10 %adc(1 34)%
                     
                    if adc(1 34)>501
                    then
                    EA="OFF"
                    PRE=0
                    +>publish stat/%topic%/RESULT {"Presence":%0PRE%}
                    print TEXT ON %EA%
                    print Wert ON %WA%
                    print Presence %PRE%
                    endif
                     
                    if adc(1 34)<500
                    then
                    +>publish stat/%topic%/RESULT {"Presence":%0PRE%}
                    EA="ON"
                    PRE=1
                    print TEXT OFF %EA%
                    print Wert OFF %WA%
                    print Presence %PRE%
                    endif
                     
                     
                    Timer=0
                     
                     
                    >W
                    LD2410 Presence{m} %EA% 
                    
                    #
                    
                    Ralla66 2 Replies Last reply Reply Quote 0
                    • Ralla66
                      Ralla66 Most Active @smarthome2020 last edited by Ralla66

                      @smarthome2020

                      schau auf der Main Seite bei Tasmota nach.
                      dies soll LD2410 Presence mit Wert auf der Main Seite anzeigen.

                      W
                      LD2410 Presence{m} %EA%

                      wenn nicht fehlt in der .bin use Web .......

                      1 Reply Last reply Reply Quote 0
                      • Ralla66
                        Ralla66 Most Active @smarthome2020 last edited by Ralla66

                        @smarthome2020

                        das hier :

                        W
                        The lines in this section are displayed in the web UI main page. Requires compiling with #define USE_SCRIPT_WEB_DISPLAY.

                        Nachtrag, den GPIO A0 Wert Main kannste testen mit 3,3 V vom ESP nach GPIO.
                        Schau mal in der Doku LD nach, meine 3,3 V ist Presence.

                        S Wal 2 Replies Last reply Reply Quote 0
                        • S
                          smarthome2020 @Ralla66 last edited by

                          @ralla66
                          Wo hast du die Infos her?

                          Die Presence Anzeige ist nun da. Im Skript ist bei > 500 aber auf Off gestellt und bei <500 auf on. Muss dsa nicht andersherum sein?

                          Ralla66 1 Reply Last reply Reply Quote 0
                          • Ralla66
                            Ralla66 Most Active @smarthome2020 last edited by Ralla66

                            @smarthome2020

                            Info Scripting
                            und Beitrag vom 8. Okt. 2023, 15:14

                            <> On / OFF ist ja vom Sensor und dem ESP abhängig.
                            Es gibt auch Bewegungsmelder dort ist das anders herum.
                            Die 500 dient ja nur dazu kleine Spannungsschwankungen auf der Leitung
                            auszublenden. Kannste auch auf 2000 stellen.
                            Könntest auch mit Pull Down / UP arbeiten, eben mehr Hardware.

                            S 1 Reply Last reply Reply Quote 0
                            • S
                              smarthome2020 @Ralla66 last edited by

                              @ralla66
                              Funktioniert nun passabel. Nun brauche ich nur noch ein Case . Danke nochmal für deine Hilfe. Funktioniert nun viel besser als mit ESpHome

                              Ralla66 1 Reply Last reply Reply Quote 0
                              • Ralla66
                                Ralla66 Most Active @smarthome2020 last edited by

                                @smarthome2020

                                ;switch case state machine
                                switch state
                                case 1
                                print state=%state% , start
                                state+=1
                                case 2
                                print state=%state%
                                state+=1
                                case 3
                                print state=%state% , reset
                                state=1
                                ends

                                1 Reply Last reply Reply Quote 0
                                • Wal
                                  Wal Developer @Ralla66 last edited by

                                  @ralla66 ,@smarthome2020,
                                  den Wert analog zu lesen ist Blödsinn, da man den Pin direkt digital auslesen kann.

                                  Ralla66 1 Reply Last reply Reply Quote 0
                                  • Ralla66
                                    Ralla66 Most Active @Wal last edited by

                                    @wal

                                    Ah.........ja, Download der Dokumente wurde am 8. Okt. 2023, 15:14 erwähnt.

                                    Wal 1 Reply Last reply Reply Quote 0
                                    • Wal
                                      Wal Developer @Ralla66 last edited by

                                      @ralla66 ,
                                      ich bin nicht beratungsresistent und würde gerne wissen warum du den DI vom Sensor analog auswertest, ich kann in der Doku den Grund nicht erkennen.
                                      Meine Antwort damals war nicht negativ gemeint, sondern sollte motivierend sein um den Lerneffekt zu verstärken.
                                      In ESPHome z.B. nutzen sie den DigitalOut vom Sensor nicht, sondern errechnen ihn vom Seriellen Input.

                                      Ralla66 1 Reply Last reply Reply Quote 0
                                      • Ralla66
                                        Ralla66 Most Active @Wal last edited by Ralla66

                                        @wal

                                        Jeder sollte seine DIY Projekte so gestalten wie er möchte.
                                        Warum ist das Analog, in den Normen etc ist ja beschrieben was Digital ist.
                                        Die Annahme das Pegel High eine Digitale 1 ist stimmt so nicht.
                                        Was ist High, > 2,5 Volt ?
                                        Mal angenommen der Sensor IC wertet die Rücklaufzeiten des Signals aus und
                                        gibt das als Spannungswert von 0 bis 3,3 Volt aus.
                                        Das wurde ja noch nicht getestet.
                                        Da es noch andere Bewegungsmelder gibt die A0 und D0 können ist es von Vorteil
                                        hier den Analog Pin zu wählen.

                                        Wal 1 Reply Last reply Reply Quote 0
                                        • Wal
                                          Wal Developer @Ralla66 last edited by

                                          @ralla66 sagte in Tasmota ESPHome Presence Sensor LD2410:

                                          Jeder sollte seine DIY Projekte so gestalten wie er möchte.

                                          Finde ich i.O.

                                          @ralla66 sagte in Tasmota ESPHome Presence Sensor LD2410:

                                          Das wurde ja noch nicht getestet.

                                          Ich kann nur sagen wenn ich im Raum bin gibt der Pin mir ein true aus wenn nicht ein false.
                                          Fehlmessungen sind mir noch nicht aufgefallen.

                                          Ich nutze den AI vom Wemos meistens für die Auswertung von der Spannungsversorgung, darauf möchte ich ungern verzichten.

                                          S 1 Reply Last reply Reply Quote 0
                                          • S
                                            smarthome2020 @Wal last edited by

                                            @wal sagte in Tasmota ESPHome Presence Sensor LD2410:

                                            @ralla66 sagte in Tasmota ESPHome Presence Sensor LD2410:

                                            Jeder sollte seine DIY Projekte so gestalten wie er möchte.

                                            Finde ich i.O.

                                            @ralla66 sagte in Tasmota ESPHome Presence Sensor LD2410:

                                            Das wurde ja noch nicht getestet.

                                            Ich kann nur sagen wenn ich im Raum bin gibt der Pin mir ein true aus wenn nicht ein false.
                                            Fehlmessungen sind mir noch nicht aufgefallen.

                                            Ich nutze den AI vom Wemos meistens für die Auswertung von der Spannungsversorgung, darauf möchte ich ungern verzichten.

                                            Nach der Hilfe von @Ralla66 geht der Sensor perfekt . Wie kann man ihn denn besser machen ?

                                            Ralla66 Wal 2 Replies Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            1.1k
                                            Online

                                            31.7k
                                            Users

                                            79.7k
                                            Topics

                                            1.3m
                                            Posts

                                            17
                                            187
                                            27955
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo