      foxthefox Developer @foxthefox last edited by foxthefox

      Folgende Grenzen sind derzeitig eingestellt:

      deltamini:

      • cfgFastChgWatts: { min: 200, max: 900 }
      • cfgSlowChgWatts: { min: 200, max: 800 }

      delta:

      • cfgFastChgWatts: { min: 200, max: 1200 }
      • cfgSlowChgWatts: { min: 200, max: 700 }

      deltamax:

      • cfgFastChgWatts: { min: 200, max: 2200 }
      • cfgSlowChgWatts: { min: 200, max: 700 }

      deltapro:
      *cfgFastChgWatts: { min: 200, max: 2900 }

      • cfgSlowChgWatts: { min: 200, max: 2900 }

      delta2:

      • cfgChgWatts: { min: 200, max: 1200 }

      delta2max:

      • SlowChgWatts: { min: 200, max: 2400 }

      Hier wäre eine Rückmeldung gut, welche Grenzen in der APP einstellbar sind.

      EDIT:
      ist nun im Adapter unter doc/devices dokumentiert

      A Norbert Göpel 2 Replies Last reply Reply Quote 0
      • A
        aherby @foxthefox last edited by

        @foxthefox said in Neuer Adapter ecoflow-mqtt:

        delta2max:

        SlowChgWatts: { min: 200, max: 2400 }

        • chgPauseFlag { 0, 1 } bisher nur mit SlowChgWatts und FastChgWatts getestet
        • Piepen on / off
        • dcChgCfg Autoeingang1 { 4000, 6000, 8000 }
        • dcChgCfg2 Autoeingang2 { 4000, 6000, 8000 }
          unabhängig steuerbar, es werden beide AddParm benötigt
        • openOilSoc, closeOilSoc
          Ein-Ausschalten des Smart Generators { min: 0, max: 100 }
        • X-Boost on /off {"enabled":255,"out_freq":255,"out_voltage":4294967295,"xboost":0} , {"enabled":255,"out_freq":255,"out_voltage":4294967295,"xboost":1}
        • AC on /off "enabled":0,"out_freq":255,"out_voltage":4294967295,"xboost":255}, "enabled":1,"out_freq":255,"out_voltage":4294967295,"xboost":255}
        • Ac immer eingeschaltet on / off
        • Backup-Reserve on / off
        • Weitere Backupwerte { min: Entladegrenze + 5, max: 100 } wobei die 5 auch indirekt geändert werden kann
        F 1 Reply Last reply Reply Quote 0
        • F
          foxthefox Developer @aherby last edited by foxthefox

          @aherby sagte in Neuer Adapter ecoflow-mqtt:
          Danke für die Rückmeldung, die obige Frage zu den Grenzen war eigentlich nur auf die Leistungen beschränkt.

          Noch ein paar Fragen/Anmerkungen dazu (immer unterhalb):

          chgPauseFlag { 0, 1 } bisher nur mit SlowChgWatts und FastChgWatts getestet

          das baue ich noch ein für die Delta2Max

          Piepen on / off

          das sollte jetzt schon funktionieren, richtig?

          dcChgCfg Autoeingang1 { 4000, 6000, 8000 }

          die Werte werden auf A umgerechnet (bei Befehl wieder auf mA), der erste Ausgang sollte jetzt schon funktionieren, richtig?

          dcChgCfg2 Autoeingang2 { 4000, 6000, 8000 }

          dies müsste dann der Datenpunkt mppt.pv2DcChgCurrent bei mir sein, den mache ich dann bedienbar

          unabhängig steuerbar, es werden beide AddParm benötigt

          wie sieht denn hier der String aus, wenn man in der APP bedient? Dazu debug modus und das Häckchen für msgSetGetPstation setzen

          openOilSoc, closeOilSoc
          Ein-Ausschalten des Smart Generators { min: 0, max: 100 }

          das sollte jetzt schon funktionieren, richtig?

          X-Boost on /off {"enabled":255,"out_freq":255,"out_voltage":4294967295,"xboost":0} , {"enabled":255,"out_freq":255,"out_voltage":4294967295,"xboost":1}

          wenn es derzeitig noch nicht geht, dann baue ich die Zusatzdinge mit ein.

          AC on /off "enabled":0,"out_freq":255,"out_voltage":4294967295,"xboost":255}, "enabled":1,"out_freq":255,"out_voltage":4294967295,"xboost":255}

          wenn es derzeitig noch nicht geht, dann baue ich die Zusatzdinge mit ein.

          Ac immer eingeschaltet on / off

          das müsste der Datenpunkt pd.newAcAutoOnCfg sein, also bei APP Bedienung dieser Funktion sollte der sich ändern?
          das sollte jetzt schon funktionieren, richtig?

          Backup-Reserve on / off

          Gibt es in der APP einen Schalter dazu? Bei der DeltaPro kann man wohl nichts schalten, das ergibt sich wohl.

          Weitere Backupwerte { min: Entladegrenze + 5, max: 100 } wobei die 5 auch indirekt geändert werden kann

          das sollte jetzt schon funktionieren, richtig?

          F A 2 Replies Last reply Reply Quote 0
          • F
            foxthefox Developer @foxthefox last edited by foxthefox

            habe 0.0.2 in github eingestellt

            • pv2DcChgCurrent as level in delta2max
            • *pv2DcChgCurrent with range 4-8 and step 2
            • chgPauseFlag as switch in delta2max

            Damit Änderungen an Datenpunkten wirksam werden, sind diese zu löschen.

            • Adpter stoppen
            • Datenpunkte/struktur von der powerstation/powerstream löschen
            • Adapter update
            • Adapter start
            1 Reply Last reply Reply Quote 0
            • S
              sirdir last edited by

              ich krieg nicht mal die installation hin. experten und dann die url bei github als quelle? Installation Icon bleibt grau… hab’s dann mal mit npm -i versucht, da find ich den adapter dann nicht nach der installation

              A F 2 Replies Last reply Reply Quote 0
              • A
                aherby @sirdir last edited by

                @sirdir 3c45f648-db98-4f09-86dd-8705e8017b79-grafik.png

                1 Reply Last reply Reply Quote 0
                • F
                  foxthefox Developer @sirdir last edited by

                  @sirdir
                  leider ist der Adapter zu neu, deswegen aus github zu installieren

                  Siehe markierte Stellen

                  Bildschirmfoto 2023-11-03 um 23.24.49.png

                  S 1 Reply Last reply Reply Quote 0
                  • S
                    sirdir @foxthefox last edited by sirdir

                    @foxthefox das ging auch nicht… weiss die genaue Fehlermeldung nicht mehr, aber irgendwie ist das Ding plötzlich in der Liste unter github aufgetaucht und ich konnte es von da installieren.
                    Jetzt kämpfe ich mit dem Einloggen. Methode 3 versteh ich nicht. Nicht möglich ist? Aber doch? Den Knopf Create Login Data kann ich nicht drücken… Krieg auch mit den Daten aus den anderen Möglichkeiten keine Verbindung hin. Im Log steht was von Admin adapter hätte falsche Version, wüsste aber nicht, wo ich eine andere her kriege… es scheint keine neuere zu geben.

                    F 1 Reply Last reply Reply Quote 0
                    • F
                      foxthefox Developer @sirdir last edited by

                      @sirdir
                      Nach der Installation sollte es so aussehen.

                      Bildschirmfoto 2023-11-04 um 08.58.46.png

                      Unter 1,2 die Zugangsdaten bei ecoflow eingeben, dann 3 drücken.
                      Danach erscheint 4, dort die Daten Herauskopieren und bei 5 in die 4 Felder einsetzen.

                      Ursprünglich war es angedacht, daß die 4 Felder sich automatisch befüllen, das geht aber noch nicht.
                      Deswegen die Kopiererei.

                      Die Webseite oder das script spuckt genau die gleichen Daten für 5 aus.

                      Gruß
                      Klaus

                      PS. Ich habe die admin 6.12.2 aus npm installiert und nach der fragt er auch ab.

                      S 1 Reply Last reply Reply Quote 0
                      • A
                        aherby @foxthefox last edited by

                        @foxthefox ich habe den Login oder Zugang noch nicht hinbekommen oder eingerichtet.

                        chgPauseFlag { 0, 1 } bisher nur mit SlowChgWatts und FastChgWatts getestet

                        • {"params":{"slowChgWatts":600,"fastChgWatts":255,"chgPauseFlag":0} Befehl für die D2m

                        Piepen on / off

                        • {"enabled":0},"from":"iOS","lang":"de-de","id":"402xx","moduleSn":"R51Zxxx","moduleType":1,"operateType":"quietCfg","version":"1.0"}
                          -{"enabled":1},"from":"iOS","lang":"de-de","id":"402xx","moduleSn":"R51Zxxx","moduleType":1,"operateType":"quietCfg","version"🕐

                        dcChgCfg Autoeingang1 { 4000, 6000, 8000 } ja werden in der App umgerechnet aber unter Parameter immer in mA.
                        Bei der D2M werden immer beide Werte benötigt. Es hatte mal mit Wert "255" im Script funktiont das nur ein Eingang geändert wurde, klappt leider nicht mehr. Ich weiß nicht ob am den Wert der nicht verändert wird zwischenspeichern müsste, den zu änderen auf einen der drei Werte verändert und dann beides komplett hinschicken sollte. Vielleicht eine Idee.

                        • {"params":{"dcChgCfg":6000,"dcChgCfg2":"8000"},"from":"iOS","lang":"de-de","id":"1698xx","moduleSn":"R51Zxxx","moduleType":5,"operateType":"dcChgCfg","version":"1.0"}
                          hier Wert 6A für Eingang 1 und 8A für Eingang2
                        • {"params":{"dcChgCfg":4000,"dcChgCfg2":"4000"},"from":"iOS","lang":"de-de","id":"1698837885262","moduleSn":"R51Zxxx","moduleType":5,"operateType":"dcChgCfg","version":"1.0"}

                        mppt.pv2DcChgCurrent

                        • ich würde vom Namen auf einen Solareingangswert vom Strom tippen. Aber gerade auch mal in der App den Wert für Autoeingang2 geändert und der mppt.pv2DcChgCurrent wird auch auf den entsprechenden Wert gesetzt.

                        openOilSoc

                        • {"params":{"openOilSoc":19},"from":"iOS","lang":"de-de","id":"278xxx","moduleSn":"R51Zxxx","moduleType":2,"operateType":"openOilSoc","version":"1.0"}
                          ( { min: 0, max: 30 } )
                          closeOilSoc
                        • {"params":{"closeOilSoc":76},"from":"iOS","lang":"de-de","id":"279xx","moduleSn":"R51Zxxx","moduleType":2,"operateType":"closeOilSoc","version":"1.0"}
                          ( { min: 50, max: 1000 } )

                        pd.newAcAutoOnCfg

                        • {"params":{"enabled":0,"minAcSoc":10},"from":"iOS","lang":"de-de","id":"317958541","moduleSn":"R51Zxxx","moduleType":1,"operateType":"newAcAutoOnCfg","version":"1.0"}
                        • {"params":{"enabled":1,"minAcSoc":10},"from":"iOS","lang":"de-de","id":"317958541","moduleSn":"R51Zxxx","moduleType":1,"operateType":"newAcAutoOnCfg","version":"1.0"}

                        Backup-Reserve on / off

                        • {"params":{"bpPowerSoc":24,"minChgSoc":0,"isConfig":0,"minDsgSoc":0},"from":"iOS","lang":"de-de","id":"421964987","moduleSn":"R51Zxxx","moduleType":1,"operateType":"watthConfig","version":"1.0"}
                          -{"params":{"bpPowerSoc":24,"minChgSoc":0,"isConfig":1,"minDsgSoc":0},"from":"iOS","lang":"de-de","id":"421964987","moduleSn":"R51Zxxx","moduleType":1,"operateType":"watthConfig","version"🕛

                        Backup-Reserve

                        • bpPowerSoc" der Wert ist beid er App-Änderung immer 5%-Punkte über der eingestellten Entladegrenze

                        Bin mal auf die neuen Funktionen mit den Firmware-Updates gespannt

                        1 Reply Last reply Reply Quote 0
                        • S
                          sirdir @foxthefox last edited by

                          @foxthefox ich denke es liegt an der admin version. Ich kenn mich mit iobroker wohl zu wenig aus. Hab die 6.12.2 installiert gekriegt und wird mir unter adapter auch angezeigt. laut log wird sie auch geladen, aber unter instances ist immer noch die 6.12.0 aktiv und ich weiss nicht wie ich die ersetze ohne mir den Teppich unter den Füssen weg zu ziehen. Ausserdem wenn ich ne weitere instanz des angeblichen 6.12.2 installieren wollte wird der auch wieder mit 6.12.0 angezeigt…

                          F 1 Reply Last reply Reply Quote 0
                          • F
                            foxthefox Developer @sirdir last edited by

                            @sirdir
                            ich stell es mal auf etwas tieferes wie 6.12.0

                            F 1 Reply Last reply Reply Quote 0
                            • F
                              foxthefox Developer @foxthefox last edited by foxthefox

                              Habe die Version 0.0.3 in github eingestellt

                              • (foxthefox) requirement for admin 6.12.2 -> 6.12.0
                              • (foxthefox) iverter_heartbeat pv1InputCur, pv2InputCur factor corrected now 0.1
                              • (foxthefox) ems.chgAmp factor 0.0001 ( seemed too high by factor 10 )
                              • (foxthefox) bmsMaster.tagChgAmp factor 0.0001 ( seemed too high by factor 10 )
                              • (foxthefox) delta2max command for cfgDcChgCurrent/pv2DcChgCurrent changed
                              • (foxthefox) ensuring that commanded bppowerSoc value is always minimum 5% higher than the ems.minDsgSoc, also putting actual minDsgSoc into the command

                              Damit Änderungen an Datenpunkten wirksam werden, sind diese zu löschen.

                              • Adapter stoppen
                              • Datenpunkte/struktur von der powerstation/powerstream löschen
                              • Adapter update
                              • Adapter start

                              @aherby
                              den Schalter für Backup-Reserve habe ich noch nicht drin
                              Wozu dient dieser?
                              pd.newAcAutoOnCfg hat als Parameter "minAcSoc", wovon hängt dieser ab? minChgSoc scheint es ja nicht zu sein.

                              A 1 Reply Last reply Reply Quote 0
                              • S
                                sirdir last edited by

                                Danke jetzt funktioniert alles wie es soll!

                                1 Reply Last reply Reply Quote 0
                                • F
                                  foxthefox Developer last edited by

                                  @sirdir
                                  super

                                  feedPriority ist auch schon drin

                                  0.0.4

                                  • (foxthefox) new switch inverter_heartbeat.feedPriority (handling the excessive solar energy when battery is full)
                                  S 1 Reply Last reply Reply Quote 1
                                  • S
                                    sirdir @foxthefox last edited by

                                    @foxthefox der klappt aber auch erst lesend, oder? Wenn ich ihn überschreibe wird er gleich wieder zurückgeändert.

                                    F 1 Reply Last reply Reply Quote 0
                                    • F
                                      foxthefox Developer @sirdir last edited by foxthefox

                                      @sirdir sagte in Neuer Adapter ecoflow-mqtt:

                                      @foxthefox der klappt aber auch erst lesend, oder? Wenn ich ihn überschreibe wird er gleich wieder zurückgeändert.

                                      bei mir bleib es erhalten, ich prüfe nochmal

                                      EDIT:
                                      hab nochmal reingeschaut, beim false habe ich noch pdata drin gehabt, das muss raus

                                      EDIT2:
                                      war ein Schreibfehler für die Spezialbehandlung dieses Befehls, kommt mit 0.0.5

                                      F 1 Reply Last reply Reply Quote 1
                                      • A
                                        aherby @foxthefox last edited by

                                        @foxthefox
                                        @aherby
                                        den Schalter für Backup-Reserve habe ich noch nicht drin
                                        Wozu dient dieser?

                                        • Da meine D2M gerade leer ist und ich nicht in der nähe kann ich den Text aus der App für den Schalter Backupresvere nicht nachlesen. Der Schalter erhöht eindach denke ich die untere Ladegrenze. Ob damit noch etwas anderes geändert wird, noch nie getestet.

                                        pd.newAcAutoOnCfg hat als Parameter "minAcSoc", wovon hängt dieser ab? minChgSoc scheint es ja nicht zu sein.
                                        Denke von dem was Ecoflow einstellt oder eingestellt hat. Ändern über die App kann man den nicht.
                                        newAcAutoOnCfg hat ja die Funktion den AC 230V-Ausgang erstmal nicht auszuschalten. Vielleicht ist das noch eine Schutzfunktion für den Akku

                                        S 1 Reply Last reply Reply Quote 0
                                        • F
                                          foxthefox Developer @foxthefox last edited by foxthefox

                                          @foxthefox

                                          Korrektur ist drin.
                                          Es gibt auch noch die Energiewerte unterhalb vom powerstream

                                          Erste interpretation dazu
                                          watth1= zu hauslasten, andere verbraucher
                                          watth2= zu plugs
                                          watth3= zu Akku
                                          watth4= vom akku, vollstaendige entladung
                                          watth5=
                                          watth6=
                                          watth7= von solar PV1
                                          watth8= von solar PV2

                                          0.0.5

                                          • (foxthefox) cfgDcChgCurrent/pv2DcChgCurrent again with min=0, seems that there comes 0 at a certein telegram and causing warning
                                          • (foxthefox) energy values (yield per day) for powerstream
                                          A 1 Reply Last reply Reply Quote 0
                                          • A
                                            aherby @foxthefox last edited by

                                            @foxthefox said in Neuer Adapter ecoflow-mqtt:

                                            foxthefox) cfgDcChgCurrent/pv2DcChgCurrent again with min=0, seems that there comes 0 at a certein telegram and causing warning
                                            (foxthefox) energy values (yield per day) for powerstream

                                            Ecoflow sieht keine 0 bei den Eingängen vor. Immer nur 4A (4000) 6A (6000) 8A (8000) aber wie schon geschrieben kann jeder Eingang einzeln verändert werden.

                                            F 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            807
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            38
                                            508
                                            79166
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo