    Rolladenlevel Wert fehlerhaft CCU Homematic / IoBroker

    This topic has been deleted. Only users with topic management privileges can see it.
    • Homoran
      Homoran Global Moderator Administrators @KennyNinetySix last edited by

      @kenny-miller sagte in Rolladenlevel Wert fehlerhaft CCU Homematic / IoBroker:

      Könnte das damit was zutun haben ?

      aber sicher!

      unzulässige Zeichen vergeben?

      1 Reply Last reply Reply Quote 0
      • Homoran
        Homoran Global Moderator Administrators @KennyNinetySix last edited by

        @kenny-miller sagte in Rolladenlevel Wert fehlerhaft CCU Homematic / IoBroker:

        00221F298AC79C:2":{"Name":"Bad%20Lichtschalter%3AC79C%3A2%3ATaster","Interface":"HmIP-RF"},

        wie sähe Kanal 3 aus?

        KennyNinetySix 1 Reply Last reply Reply Quote 0
        • Samson71
          Samson71 Global Moderator @Homoran last edited by Samson71

          @homoran sagte in Rolladenlevel Wert fehlerhaft CCU Homematic / IoBroker:

          nachher ist Kanal 14 nur einer der virtuellen Kanäle und nicht konfiguriert

          Mangels HmiPW kann ich das auch nicht genau sagen, halte das aber für möglich. Viele virtuelle Kanäle muss man ja auch nicht zwingend nutzen. Man müsste mal alle Kanäle in der Übersicht in der CCU dazu sehen. Der eine Kanal in der Vereinzelung ist dazu nen bisschen wenig.

          EDIT
          Die Teile haben glaube ich pro Schaltkanal 3 virtuelle Kanäle für Direktverknüpfungen u.ä. Das erklärt die hohe Anzahl an Kanälen.

          1 Reply Last reply Reply Quote 0
          • KennyNinetySix
            KennyNinetySix @Homoran last edited by

            @homoran

            Cannot parse answer for devices: {"00221F298AC6B1":{"Name":"AnbauRolladen%20rechts%3AC6B1","Interface":"HmIP-RF"}, "00221F298AC6B1:0":{"Name":"AnbauRolladen%20rechts%3AC6B1%3A0","Interface":"HmIP-RF"}, "00221F298AC6B1:1":{"Name":"AnbauRolladen%20rechts%3AC6B1%3A1%3ATaster","Interface":"HmIP-RF"}, "00221F298AC6B1:2":{"Name":"AnbauRolladen%20rechts%3AC6B1%3A2%3ATaster","Interface":"HmIP-RF"}, "00221BE98E64CA":{"Name":"Baby%20Lichtschalter%3A64CA","Interface":"HmIP-RF"}, "00221BE98E64CA:0":{"Name":"Baby%20Lichtschalter%3A64CA%3A0","Interface":"HmIP-RF"}, "00221BE98E64CA:1":{"Name":"Baby%20Lichtschalter%3A64CA%3A1%3ATaster","Interface":"HmIP-RF"}, "00221BE98E64CA:2":{"Name":"Baby%20Lichtschalter%3A64CA%3A2%3ATaster","Interface":"HmIP-RF"}, "00221BE98E6449":{"Name":"Baby%20Rolladen%3A6449","Interface":"HmIP-RF"}, "00221BE98E6449:0":{"Name":"Baby%20Rolladen%3A6449%3A0","Interface":"HmIP-RF"}, "00221BE98E6449:1":{"Name":"Baby%20Rolladen%3A6449%3A1%3ATaster","Interface":"HmIP-RF"}, "00221BE98E6449:2":{"Name":"Baby%20Rolladen%3A6449%3A2%3ATaster","Interface":"HmIP-RF"}, "001CDD89BEA2F2":{"Name":"Baby%20Thermostat%3AA2F2","Interface":"HmIP-RF"}, "001CDD89BEA2F2:0":{"Name":"Baby%20Thermostat%3AA2F2%3A0","Interface":"HmIP-RF"}, "001CDD89BEA2F2:1":{"Name":"Baby%20Thermostat%3AA2F2%3A1%3AVerkn%FCpfungspartner%20Heizungsthermostat%20(manuelle%20Bedienung%2C%20Sender)","Interface":"HmIP-RF"}, "001CDD89BEA2F2:2":{"Name":"Baby%20Thermostat%3AA2F2%3A2%3AVerkn%FCpfungspartner%20Heizungsthermostat%20(manuelle%20Bedienung%2C%20Empf%E4nger)","Interface":"HmIP-RF"}, "001CDD89BEA2F2:3":{"Name":"Baby%20Thermostat%3AA2F2%3A3%3AVerkn%FCpfungspartner%20Heizungsthermostat%20(zykl.%20Daten%2C%20Soll-%20u.%20Ist-Temp.)","Interface":"HmIP-RF"}, "001CDD89BEA2F2:4":{"Name":"Baby%20Thermostat%3AA2F2%3A4%3AVerkn%FCpfungspartner%20T%FCr-%2FFensterkontakt","Interface":"HmIP-RF"}, "001CDD89BEA2F2:5":{"Name":"Baby%20Thermostat%3AA2F2%3A5%3AVerkn%FCpfungspartner%20Schaltaktor%20f%FCr%20Zweipunktregelung","Interface":"HmIP-RF"}, "001CDD89BEA2F2:6":{"Name":"Baby%20Thermostat%3AA2F2%3A6%3AVerkn%FCpfungspartner%20Taster","Interface":"HmIP-RF"}, "001CDD89BEA2F2:7":{"Name":"Baby%20Thermostat%3AA2F2%3A7%3AVerkn%FCpfungspartner%20Fussbodenheizung","Interface":"HmIP-RF"}, "00221F298AC79C":{"Name":"Bad%20Lichtschalter%3AC79C","Interface":"HmIP-RF"}, "00221F298AC79C:0":{"Name":"Bad%20Lichtschalter%3AC79C%3A0","Interface":"HmIP-RF"}, "00221F298AC79C:1":{"Name":"Bad%20Lichtschalter%3AC79C%3A1%3ATaster","Interface":"HmIP-RF"}, "00221F298AC79C:2":{"Name":"Bad%20Lichtschalter%3AC79C%3A2%3ATaster","Interface":"HmIP-RF"}, "00221F298AC7B3":{"Name":"Bad%20Rolladen%3AC7B3","Interface":"HmIP-RF"}, "00221F298AC7B3:0":{"Name":"Bad%20Rolladen%3AC7B3%3A0","Interface":"HmIP-RF"}, "00221F298AC7B3:1":{"Name":"Bad%20Rolladen%3AC7B3%3A1%3ATaster","Interface":"HmIP-RF"}, "00221F298AC7B3:2":{"Name":"Bad%20Rolladen%3AC7B3%3A2%3ATaster","Interface":"HmIP-RF"}, "001CDD89BEA3D0":{"Name":"Bad%20Thermostat%3AA3D0","Interface":"HmIP-RF"}, "001CDD89BEA3D0:0":{"Name":"Bad%20Thermostat%3AA3D0%3A0","Interface":"HmIP-RF"}, "001CDD89BEA3D0:1":{"Name":"Bad%20Thermostat%3AA3D0%3A1%3AVerkn%FCpfungspartner%20Heizungsthermostat%20(manuelle%20Bedienung%2C%20Sender)","Interface":"HmIP-RF"}, "001CDD89BEA3D0:2":{"Name":"Bad%20Thermostat%3AA3D0%3A2%3AVerkn%FCpfungspartner%20Heizungsthermostat%20(manuelle%20Bedienung%2C%20Empf%E4nger)","Interface":"HmIP-RF"}, "001CDD89BEA3D0:3":{"Name":"Bad%20Thermostat%3AA3D0%3A3%3AVerkn%FCpfungspartner%20Heizungsthermostat%20(zykl.%20Daten%2C%20Soll-%20u.%20Ist-Temp.)","Interface":"HmIP-RF"}, "001CDD89BEA3D0:4":{"Name":"Bad%20Thermostat%3AA3D0%3A4%3AVerkn%FCpfungspartner%20T%FCr-%2FFensterkontakt","Interface":"HmIP-RF"}, "001CDD89BEA3D0:5":{"Name":"Bad%20Thermostat%3AA3D0%3A5%3AVerkn%FCpfungspartner%20Schaltaktor%20f%FCr%20Zweipunktregelung","Interface":"HmIP-RF"}, "001CDD89BEA3D0:6":{"Name":"Bad%20Thermostat%3AA3D0%3A6%3AVerkn%FCpfungspartner%20Taster","Interface":"HmIP-RF"}, "001CDD89BEA3D0:7":{"Name":"Bad%20Thermostat%3AA3D0%3A7%3AVerkn%FCpfungspartner%20Fussbodenheizung","Interface":"HmIP-RF"}, "001CDA49910C65":{"Name":"Buero%20Thermostat%3A0C65","Interface":"HmIP-RF"}, "001CDA49910C65:0":{"Name":"Buero%20Thermostat%3A0C65%3A0","Interface":"HmIP-RF"}, "001CDA49910C65:1":{"Name":"Buero%20Thermostat%3A0C65%3A1%3AVerkn%FCpfungspartner%20Heizungsthermostat%20(manuelle%20Bedienung%2C%20Sender)","Interface":"HmIP-RF"}, "001CDA49910C65:2":{"Name":"Buero%20Thermostat%3A0C65%3A2%3AVerkn%FCpfungspartner%20Heizungsthermostat%20(manuelle%20Bedienung%2C%20Empf%E4nger)","Interface":"HmIP-RF"}, "001CDA49910C65:3":{"Name":"Buero%20Thermostat%3A0C65%3A3%3AVerkn%FCpfungspartner%20Heizungsthermostat%20(zykl.%20Daten%2C%20Soll-%20u.%20Ist-Temp.)","Interface":"HmIP-RF"}, "001CDA49910C65:4":{"Name":"Buero%20Thermostat%3A0C65%3A4%3AVerkn%FCpfungspartner%20T%FCr-%2FFensterkontakt","Interface":"HmIP-RF"}, "001CDA49910C65:5":{"Name":"Buero%20Thermostat%3A0C65%3A5%3AVerkn%FCpfungspartner%20Schaltaktor%20f%FCr%20Zweipunktregelung","Interface":"HmIP-RF"}, "001CDA49910C65:6":{"Name":"Buero%20Thermostat%3A0C65%3A6%3AVerkn%FCpfungspartner%20Taster","Interface":"HmIP-RF"}, "001CDA49910C65:7":{"Name":"Buero%20Thermostat%3A0C65%3A7%3AVerkn%FCpfungspartner%20Fussbodenheizung","Interface":"HmIP-RF"}, "00221BE98E6311":{"Name":"B%FCro%20Lichtschalter%3A6311","Interface":"HmIP-RF"}, "00221BE98E6311:0":{"Name":"B%FCro%20Lichtschalter%3A6311%3A0","Interface":"HmIP-RF"}, "00221BE98E6311:1":{"Name":"B%FCro%20licht%20an%3A6311%3A1%3ATaster","Interface":"HmIP-RF"}, "00221BE98E6311:2":{"Name":"B%FCro%20Licht%20aus%3A6311%3A2%3ATaster","Interface":"HmIP-RF"}
            
            Homoran 2 Replies Last reply Reply Quote 0
            • Homoran
              Homoran Global Moderator Administrators @KennyNinetySix last edited by

              @kenny-miller was willst du mir zeigen?
              wie ist die Antwort auf die letzte Frage?

              KennyNinetySix 1 Reply Last reply Reply Quote 0
              • Samson71
                Samson71 Global Moderator last edited by

                @Kenny-Miller
                Kanal 2 / 6 / 10 / 14 müssten die benötigten Steuer-Kanäle je Aktor sein. Soviel habe ich auf die Schnelle gelesen. Mal im Umkehrschluss probiert einen Wert im ioBroker zu setzen? Reagiert der Rollladen darauf?

                KennyNinetySix 1 Reply Last reply Reply Quote 1
                • KennyNinetySix
                  KennyNinetySix @Homoran last edited by

                  @homoran Willst du Kanal 3 im den Objects in IoBroker sehen oder in der CCU in Homematic ? Oder wolltest du wissen ob es mit Kanal 3 funktioniert ?

                  Homoran 1 Reply Last reply Reply Quote 0
                  • Homoran
                    Homoran Global Moderator Administrators @KennyNinetySix last edited by Homoran

                    @kenny-miller Das Json ist unvollständig und endet mit Kanal2, wie zitiert
                    jetzt ist die Frage gewesen ob der nächste Eintrag wegen eines Sonderzeichens o.ä. nicht gesendet wird.

                    1 Reply Last reply Reply Quote 0
                    • Homoran
                      Homoran Global Moderator Administrators @KennyNinetySix last edited by Homoran

                      @kenny-miller sagte in Rolladenlevel Wert fehlerhaft CCU Homematic / IoBroker:

                      .....00221F298AC79C:2":{"Name":"Bad%20Lichtschalter%3AC79C%3A2%3ATaster","Interface":"HmIP-RF"}, "00221F298AC7B3":{"Name":"Bad%20Rolladen%3AC7B3","Interface":"HmIP-RF"}, "00221F298AC7B3:0":{"Name":"Bad%20Rolladen%3AC7B3%3A0","Interface":"HmIP-RF"}, "00221F298AC7B3:1":{"Name":"Bad%20Rolladen%3AC7B3%3A1%3ATaster","Interface":"HmIP-RF"}, "00221F298AC7B3:2".....

                      auch dieses json ist unvollständig, aber deutlich länger als das letzte

                      1 Reply Last reply Reply Quote 0
                      • Homoran
                        Homoran Global Moderator Administrators @KennyNinetySix last edited by

                        Noch eine Frage:

                        @kenny-miller sagte in Rolladenlevel Wert fehlerhaft CCU Homematic / IoBroker:

                        leider fehlt mir ein Wert des Rolladenaktors.

                        sind bei den anderen 3

                        @samson71 sagte in Rolladenlevel Wert fehlerhaft CCU Homematic / IoBroker:

                        Kanal 2 / 6 / 10 /

                        die Level-Werte vorhanden?

                        1 Reply Last reply Reply Quote 0
                        • KennyNinetySix
                          KennyNinetySix @Samson71 last edited by

                          @samson71 Genau das ist richtig. Wenn ich den Wert 50% eingebe fährt der Rolladen bis zur Mitte. Also das klappt, er bleibt dann auch stehen und zeigt diesen Wert an. Sobald ich aber den Schalter betätige springt der Wert auf 0 oder 100%

                          Homoran 1 Reply Last reply Reply Quote 0
                          • Homoran
                            Homoran Global Moderator Administrators @KennyNinetySix last edited by Homoran

                            @kenny-miller sagte in Rolladenlevel Wert fehlerhaft CCU Homematic / IoBroker:

                            Sobald ich aber den Schalter betätige springt der Wert auf 0 oder 100%

                            sind die rollläden kalibriert?

                            wie greift "der Schalter" in das System ein?

                            1 Reply Last reply Reply Quote 0
                            • First post
                              Last post

                            Support us

                            ioBroker
                            Community Adapters
                            Donate

                            691
                            Online

                            31.9k
                            Users

                            80.3k
                            Topics

                            1.3m
                            Posts

                            3
                            49
                            1901
                            Loading More Posts
                            • Oldest to Newest
                            • Newest to Oldest
                            • Most Votes
                            Reply
                            • Reply as topic
                            Log in to reply
                            Community
                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                            The ioBroker Community 2014-2023
                            logo