      @ralla66 Habe jetzt dein original Script eingebunden:

      >D
       
      ;a valid script must start with >D in the first line
       
       
      Timer=0
       
      WEBQ=5
       
      VOL=0
      CUR=0
      POW=0
      TOT=0
      YES=0
      TOD=0
      APP=0
      RAP=0
       
      ; Meins
       
      ; MQT: tasmota_Reserve2 = {"StatusSNS":{"Time":"2023-11-14T12:59:46","ENERGY":{"TotalStartTime":"2020-06-30T13:38:42","Total":0.424,"Yesterday":0.007,"Today":0.093,"Power":42,"ApparentPower":42,"ReactivePower":0,"Factor":1.00,"Voltage":231,"Current":0.181}}}
       
      >BS
       
      +>subscribe EA, cmnd/%topic%/Total
      +>subscribe EA, cmnd/%topic%/Yesterday
      +>subscribe EA, cmnd/%topic%/Today
      +>subscribe EA, cmnd/%topic%/Power
      +>subscribe EA, cmnd/%topic%/ApparentPower
      +>subscribe EA, cmnd/%topic%/ReactivePower
      +>subscribe EA, cmnd/%topic%/Power
      +>subscribe EA, cmnd/%topic%/Voltage
      +>subscribe EA, cmnd/%topic%/Current
       
      >S
       
      Timer+=1
       
      ;Executed every second 
       
       
      if Timer>10
       
      then
      =>websend [192.168.178.164] /cm?cmnd=status 10
       
      +>publish stat/%topic%/RESULT {"Total":%0TOT%}
      +>publish stat/%topic%/RESULT {"Yesterday":%0YES%}
      +>publish stat/%topic%/RESULT {"Today":%0TOD%}
      +>publish stat/%topic%/RESULT {"ApparentPower":%0APP%}
      +>publish stat/%topic%/RESULT {"ReactivePower":%RAP%}
      +>publish stat/%topic%/RESULT {"Power":%0POW%}
      +>publish stat/%topic%/RESULT {"Voltage":%0VOL%}
      +>publish stat/%topic%/RESULT {"Current":%0CUR%}
       
      Timer=0
       
      endif
       
       
      >E
       
      ;Executed when a Tasmota MQTT RESULT message is received
       
       
      VOL=WebQuery#StatusSNS#ENERGY#Voltage
      print Wert Volt %VOL%
       
      CUR=WebQuery#StatusSNS#ENERGY#Current/1000
      print Wert Current %CUR%
       
      POW=WebQuery#StatusSNS#ENERGY#Power
      print Wert Power %POW%
       
      TOT=WebQuery#StatusSNS#ENERGY#Total
      print Wert Total %TOT%
       
      YES=WebQuery#StatusSNS#ENERGY#Yesterday
      print Wert Yesterday %YES%
       
      TOD=WebQuery#StatusSNS#ENERGY#Today
      print Wert Today %TOD%
       
      APP=WebQuery#StatusSNS#ENERGY#ApparentPower
      print Wert Apparent Power %APP%
       
      RAP=WebQuery#StatusSNS#ENERGY#ReactivePower
      print Wert Reaktive Power %RAP%
       
       
      >W
       
      ;The lines in this section are displayed in the web UI main page
       
                
      Power{m} %2POW% W
      Volt{m} %2VOL% V
      Ampere{m} %2CUR% A
      Total{m} %2TOT% 
      Yesterday{m} %YES% 
      Today{m} %2TOD% 
      Apparent{m} %2APP% 
      Reactive{m} %2RAP% 
        
      #
      

      angepasst habe ich Zeile 21 und 45

      Im Log des ioBroker steht:

      
      sonoff.0
      2023-11-14 18:48:06.358	debug	[Reserve2] Received: stat/tasmota_Reserve2/RESULT = {"WebSend":"Connect failed"}
      

      Habe keine Ahnung woran das liegen kann.

      Nachtrag:
      3322f7f1-a10c-455d-a08c-40e4eacc65db-image.png
      e66ab1cf-68b5-4c50-9994-0d9f5a8a7566-image.png

      Ralla66 2 Replies Last reply Reply Quote 0
      • Ralla66
        Ralla66 Most Active @RalfTh last edited by Ralla66

        @ralfth

        Passwort Rot ? Zum testen einfach 12345 nehmen
        Topic nicht default

        was steht in der Console ?
        websend done ?

        Nachtrag:

        Das ist alles verbogen,
        neu flashen
        gosund einrichten template
        nix an Topic / Full Topic basteln, rein gar nix !!
        im Sonoff Adapter altes löschen
        Mqtt verbinden
        das muß erst einmal rennen
        danach Script einfügen, speichern, rebooten,aktivieren

        1 Reply Last reply Reply Quote 0
        • Ralla66
          Ralla66 Most Active @RalfTh last edited by

          @ralfth

          was bastelst du da 🙂

          sp 111 14112023.jpg

          RalfTh 1 Reply Last reply Reply Quote 0
          • RalfTh
            RalfTh @Ralla66 last edited by

            @ralla66 So, habe jetzt alles so eingestellt wie du es mir in den Bildern gezeigt hast. Habe vorher den Adapter gestoppt und die Objekte gelöscht.
            Das Script ist nicht aktiviert.
            Instanz gestartet, die Objekte werden angelegt.
            Di DP's welche mit "ENERGY_" beginnen werden,wenn überhaupt nur nach einer Ewigkeit aktualisiert und das obwohl die Message ankam. Hier Auszug aus der Konsole:

            B8D3E7/POWER = ON
            07:14:16.291 MQT: tele/tasmota_B8D3E7/STATE = {"Time":"2023-11-15T07:14:16","Uptime":"0T00:36:54","UptimeSec":2214,"Heap":20,"SleepMode":"Dynamic","Sleep":50,"LoadAvg":19,"MqttCount":3,"POWER":"ON","Wifi":{"AP":1,"SSId":"Palatina","BSSId":"5C:49:79:55:9E:DC","Channel":4,"Mode":"11n","RSSI":58,"Signal":-71,"LinkCount":1,"Downtime":"0T00:00:03"}}
            07:14:16.302 MQT: tele/tasmota_B8D3E7/SENSOR = {"Time":"2023-11-15T07:14:16","ENERGY":{"TotalStartTime":"2020-06-30T13:38:42","Total":0.527,"Yesterday":0.170,"Today":0.026,"Period":0,"Power":43,"ApparentPower":43,"ReactivePower":0,"Factor":1.00,"Voltage":232,"Current":0.183}}
            07:14:46.290 MQT: tele/tasmota_B8D3E7/STATE = {"Time":"2023-11-15T07:14:46","Uptime":"0T00:37:24","UptimeSec":2244,"Heap":20,"SleepMode":"Dynamic","Sleep":50,"LoadAvg":19,"MqttCount":3,"POWER":"ON","Wifi":{"AP":1,"SSId":"Palatina","BSSId":"5C:49:79:55:9E:DC","Channel":4,"Mode":"11n","RSSI":62,"Signal":-69,"LinkCount":1,"Downtime":"0T00:00:03"}}
            07:14:46.299 MQT: tele/tasmota_B8D3E7/SENSOR = {"Time":"2023-11-15T07:14:46","ENERGY":{"TotalStartTime":"2020-06-30T13:38:42","Total":0.528,"Yesterday":0.170,"Today":0.027,"Period":0,"Power":43,"ApparentPower":43,"ReactivePower":0,"Factor":1.00,"Voltage":232,"Current":0.183}}
            07:15:16.280 MQT: tele/tasmota_B8D3E7/STATE = {"Time":"2023-11-15T07:15:16","Uptime":"0T00:37:54","UptimeSec":2274,"Heap":20,"SleepMode":"Dynamic","Sleep":50,"LoadAvg":19,"MqttCount":3,"POWER":"ON","Wifi":{"AP":1,"SSId":"Palatina","BSSId":"5C:49:79:55:9E:DC","Channel":4,"Mode":"11n","RSSI":62,"Signal":-69,"LinkCount":1,"Downtime":"0T00:00:03"}}
            07:15:16.293 MQT: tele/tasmota_B8D3E7/SENSOR = {"Time":"2023-11-15T07:15:16","ENERGY":{"TotalStartTime":"2020-06-30T13:38:42","Total":0.528,"Yesterday":0.170,"Today":0.027,"Period":0,"Power":43,"ApparentPower":43,"ReactivePower":0,"Factor":1.00,"Voltage":232,"Current":0.183}}
            07:15:46.251 MQT: tele/tasmota_B8D3E7/STATE = {"Time":"2023-11-15T07:15:46","Uptime":"0T00:38:24","UptimeSec":2304,"Heap":20,"SleepMode":"Dynamic","Sleep":50,"LoadAvg":19,"MqttCount":3,"POWER":"ON","Wifi":{"AP":1,"SSId":"Palatina","BSSId":"5C:49:79:55:9E:DC","Channel":4,"Mode":"11n","RSSI":64,"Signal":-68,"LinkCount":1,"Downtime":"0T00:00:03"}}
            07:15:46.262 MQT: tele/tasmota_B8D3E7/SENSOR = {"Time":"2023-11-15T07:15:46","ENERGY":{"TotalStartTime":"2020-06-30T13:38:42","Total":0.528,"Yesterday":0.170,"Today":0.027,"Period":0,"Power":43,"ApparentPower":43,"ReactivePower":0,"Factor":1.00,"Voltage":232,"Current":0.186}}
            07:16:16.257 MQT: tele/tasmota_B8D3E7/STATE = {"Time":"2023-11-15T07:16:16","Uptime":"0T00:38:54","UptimeSec":2334,"Heap":20,"SleepMode":"Dynamic","Sleep":50,"LoadAvg":20,"MqttCount":3,"POWER":"ON","Wifi":{"AP":1,"SSId":"Palatina","BSSId":"5C:49:79:55:9E:DC","Channel":4,"Mode":"11n","RSSI":62,"Signal":-69,"LinkCount":1,"Downtime":"0T00:00:03"}}
            07:16:16.267 MQT: tele/tasmota_B8D3E7/SENSOR = {"Time":"2023-11-15T07:16:16","ENERGY":{"TotalStartTime":"2020-06-30T13:38:42","Total":0.529,"Yesterday":0.170,"Today":0.028,"Period":0,"Power":43,"ApparentPower":43,"ReactivePower":0,"Factor":1.00,"Voltage":232,"Current":0.185}}
            07:16:46.256 MQT: tele/tasmota_B8D3E7/STATE = {"Time":"2023-11-15T07:16:46","Uptime":"0T00:39:24","UptimeSec":2364,"Heap":20,"SleepMode":"Dynamic","Sleep":50,"LoadAvg":19,"MqttCount":3,"POWER":"ON","Wifi":{"AP":1,"SSId":"Palatina","BSSId":"5C:49:79:55:9E:DC","Channel":4,"Mode":"11n","RSSI":62,"Signal":-69,"LinkCount":1,"Downtime":"0T00:00:03"}}
            07:16:46.268 MQT: tele/tasmota_B8D3E7/SENSOR = {"Time":"2023-11-15T07:16:46","ENERGY":{"TotalStartTime":"2020-06-30T13:38:42","Total":0.529,"Yesterday":0.170,"Today":0.028,"Period":0,"Power":43,"ApparentPower":43,"ReactivePower":0,"Factor":1.00,"Voltage":232,"Current":0.186}}
            07:17:16.261 MQT: tele/tasmota_B8D3E7/STATE = {"Time":"2023-11-15T07:17:16","Uptime":"0T00:39:54","UptimeSec":2394,"Heap":20,"SleepMode":"Dynamic","Sleep":50,"LoadAvg":19,"MqttCount":3,"POWER":"ON","Wifi":{"AP":1,"SSId":"Palatina","BSSId":"5C:49:79:55:9E:DC","Channel":4,"Mode":"11n","RSSI":60,"Signal":-70,"LinkCount":1,"Downtime":"0T00:00:03"}}
            07:17:16.273 MQT: tele/tasmota_B8D3E7/SENSOR = {"Time":"2023-11-15T07:17:16","ENERGY":{"TotalStartTime":"2020-06-30T13:38:42","Total":0.530,"Yesterday":0.170,"Today":0.029,"Period":0,"Power":44,"ApparentPower":44,"ReactivePower":0,"Factor":1.00,"Voltage":232,"Current":0.188}}
            07:17:46.275 MQT: tele/tasmota_B8D3E7/STATE = {"Time":"2023-11-15T07:17:46","Uptime":"0T00:40:24","UptimeSec":2424,"Heap":20,"SleepMode":"Dynamic","Sleep":50,"LoadAvg":19,"MqttCount":3,"POWER":"ON","Wifi":{"AP":1,"SSId":"Palatina","BSSId":"5C:49:79:55:9E:DC","Channel":4,"Mode":"11n","RSSI":62,"Signal":-69,"LinkCount":1,"Downtime":"0T00:00:03"}}
            07:17:46.285 MQT: tele/tasmota_B8D3E7/SENSOR = {"Time":"2023-11-15T07:17:46","ENERGY":{"TotalStartTime":"2020-06-30T13:38:42","Total":0.530,"Yesterday":0.170,"Today":0.029,"Period":0,"Power":43,"ApparentPower":43,"ReactivePower":0,"Factor":1.00,"Voltage":232,"Current":0.185}}
            

            Derweil im ioBroker:
            4ba186da-a727-4d8a-87ea-4a9fed0a30ed-image.png

            Und das, obwohl laut LOG auch hier die Informationen eintrudeln:

            8298ba6c-3c66-4b07-8f66-7a0042033f63-image.png

            Ich habe die Steckdose mittlerweile drei mal geflasht und jedesmal eine andere Konfiguration verwendet. Ich denke, ein erneutes flashen bringt da auch nicht die Lösung. Falls keine anderen Ideen mehr da sind werde ich mir einen anderen MQTT-Broker suchen und das JSON aufdröseln.

            Ralla66 1 Reply Last reply Reply Quote 0
            • Ralla66
              Ralla66 Most Active @RalfTh last edited by

              @ralfth

              alle print des Scriptes werden in der Console nicht ausgegeben, bedeutet dein Script läuft nicht.
              Topic ist noch Reserve2 und nicht default.
              Ob deine .bin überhaupt in Ordnung ist weiß keiner.
              Daher das compilieren mit Tasmocompiler. Das ist halt viel einfacher.

              Solange die Topic / Full Topic nicht in Ordnung sind und das Script nicht läuft kann
              ich auch nicht weiter helfen. Da es ja bei mir läuft liegt das ja an deinem System.

              RalfTh 1 Reply Last reply Reply Quote 0
              • RalfTh
                RalfTh @Ralla66 last edited by

                @ralla66 sagte in Gosund SP111 mit Tasmota 13.2.0 Problem mit DP:

                alle print des Scriptes werden in der Console nicht ausgegeben, bedeutet dein Script läuft nicht.

                Hatte ich auch geschrieben, dass das Script nicht aktiviert ist.

                Meine .bin habe ich mit Gitpod kompiliert (Quelle: https://github.com/arendst/Tasmota) und alle von dir genannten Defines, soweit in my_user_config.h vorhanden, aktiviert. In einem Post weiter oben hatte ich das auch schon erwähnt.
                Diese .bin habe ich dann auf den Gosund geflasht.

                Das Script habe ich jetzt aktiviert und in der Konsole kommt folgende Fehlermeldung:

                17:32:38.869 SCR: performs "websend [192.168.178.164] /cm?cmnd=status 10"
                17:32:44.249 MQT: stat/tasmota_B8D3E7/RESULT = {"WebSend":"Connect failed"}
                17:32:44.257 MQT: stat/tasmota_B8D3E7/RESULT = {"Total":0}
                17:32:44.264 MQT: stat/tasmota_B8D3E7/RESULT = {"Yesterday":0}
                17:32:44.272 MQT: stat/tasmota_B8D3E7/RESULT = {"Today":0}
                17:32:44.279 MQT: stat/tasmota_B8D3E7/RESULT = {"ApparentPower":0}
                17:32:44.286 MQT: stat/tasmota_B8D3E7/RESULT = {"ReactivePower":0.00}
                17:32:44.293 MQT: stat/tasmota_B8D3E7/RESULT = {"Power":0}
                17:32:44.300 MQT: stat/tasmota_B8D3E7/RESULT = {"Voltage":0}
                17:32:44.307 MQT: stat/tasmota_B8D3E7/RESULT = {"Current":0}
                17:32:48.393 MQT: tele/tasmota_B8D3E7/STATE = {"Time":"2023-11-15T17:32:48","Uptime":"0T10:55:26","UptimeSec":39326,"Heap":20,"SleepMode":"Dynamic","Sleep":50,"LoadAvg":19,"MqttCount":4,"POWER":"ON","Wifi":{"AP":1,"SSId":"Palatina","BSSId":"5C:49:79:55:9E:DC","Channel":4,"Mode":"11n","RSSI":96,"Signal":-52,"LinkCount":1,"Downtime":"0T00:00:03"}}
                17:32:48.406 MQT: tele/tasmota_B8D3E7/SENSOR = {"Time":"2023-11-15T17:32:48","ENERGY":{"TotalStartTime":"2020-06-30T13:38:42","Total":0.544,"Yesterday":0.170,"Today":0.043,"Period":1,"Power":42,"ApparentPower":42,"ReactivePower":0,"Factor":1.00,"Voltage":230,"Current":0.181}}
                17:32:54.371 SCR: performs "websend [192.168.178.164] /cm?cmnd=status 10"
                17:32:59.783 MQT: stat/tasmota_B8D3E7/RESULT = {"WebSend":"Connect failed"}
                17:32:59.792 MQT: stat/tasmota_B8D3E7/RESULT = {"Total":0}
                17:32:59.799 MQT: stat/tasmota_B8D3E7/RESULT = {"Yesterday":0}
                17:32:59.808 MQT: stat/tasmota_B8D3E7/RESULT = {"Today":0}
                17:32:59.815 MQT: stat/tasmota_B8D3E7/RESULT = {"ApparentPower":0}
                17:32:59.823 MQT: stat/tasmota_B8D3E7/RESULT = {"ReactivePower":0.00}
                

                Die IP für das websend ist die des ioBroker oder der Gosund?

                Hier noch mal mein Script:

                >D
                 
                ;a valid script must start with >D in the first line
                 
                 
                Timer=0
                 
                WEBQ=5
                 
                VOL=0
                CUR=0
                POW=0
                TOT=0
                YES=0
                TOD=0
                APP=0
                RAP=0
                 
                ; Meins
                 
                ; MQT: tasmota_Reserve2 = {"StatusSNS":{"Time":"2023-11-14T12:59:46","ENERGY":{"TotalStartTime":"2020-06-30T13:38:42","Total":0.424,"Yesterday":0.007,"Today":0.093,"Power":42,"ApparentPower":42,"ReactivePower":0,"Factor":1.00,"Voltage":231,"Current":0.181}}}
                 
                >BS
                 
                +>subscribe EA, cmnd/%topic%/Total
                +>subscribe EA, cmnd/%topic%/Yesterday
                +>subscribe EA, cmnd/%topic%/Today
                +>subscribe EA, cmnd/%topic%/Power
                +>subscribe EA, cmnd/%topic%/ApparentPower
                +>subscribe EA, cmnd/%topic%/ReactivePower
                +>subscribe EA, cmnd/%topic%/Power
                +>subscribe EA, cmnd/%topic%/Voltage
                +>subscribe EA, cmnd/%topic%/Current
                 
                >S
                 
                Timer+=1
                 
                ;Executed every second 
                 
                 
                if Timer>10
                 
                then
                =>websend [192.168.178.164] /cm?cmnd=status 10
                 
                +>publish stat/%topic%/RESULT {"Total":%0TOT%}
                +>publish stat/%topic%/RESULT {"Yesterday":%0YES%}
                +>publish stat/%topic%/RESULT {"Today":%0TOD%}
                +>publish stat/%topic%/RESULT {"ApparentPower":%0APP%}
                +>publish stat/%topic%/RESULT {"ReactivePower":%RAP%}
                +>publish stat/%topic%/RESULT {"Power":%0POW%}
                +>publish stat/%topic%/RESULT {"Voltage":%0VOL%}
                +>publish stat/%topic%/RESULT {"Current":%0CUR%}
                 
                Timer=0
                 
                endif
                 
                 
                >E
                 
                ;Executed when a Tasmota MQTT RESULT message is received
                 
                 
                VOL=WebQuery#StatusSNS#ENERGY#Voltage
                print Wert Volt %VOL%
                 
                CUR=WebQuery#StatusSNS#ENERGY#Current/1000
                print Wert Current %CUR%
                 
                POW=WebQuery#StatusSNS#ENERGY#Power
                print Wert Power %POW%
                 
                TOT=WebQuery#StatusSNS#ENERGY#Total
                print Wert Total %TOT%
                 
                YES=WebQuery#StatusSNS#ENERGY#Yesterday
                print Wert Yesterday %YES%
                 
                TOD=WebQuery#StatusSNS#ENERGY#Today
                print Wert Today %TOD%
                 
                APP=WebQuery#StatusSNS#ENERGY#ApparentPower
                print Wert Apparent Power %APP%
                 
                RAP=WebQuery#StatusSNS#ENERGY#ReactivePower
                print Wert Reaktive Power %RAP%
                 
                 
                >W
                 
                ;The lines in this section are displayed in the web UI main page
                 
                          
                Power{m} %2POW% W
                Volt{m} %2VOL% V
                Ampere{m} %2CUR% A
                Total{m} %2TOT% 
                Yesterday{m} %YES% 
                Today{m} %2TOD% 
                Apparent{m} %2APP% 
                Reactive{m} %2RAP% 
                 
                 
                 
                #
                

                Ich habe es nochmal verglichen. Ich habe lediglich die Zeilen 21 und 45 angepasst.

                Ralla66 1 Reply Last reply Reply Quote 0
                • Ralla66
                  Ralla66 Most Active @RalfTh last edited by Ralla66

                  @ralfth sagte in Gosund SP111 mit Tasmota 13.2.0 Problem mit DP:

                  Die IP für das websend ist die des ioBroker oder der Gosund?

                  vom Gosund, das sieht doch gut aus 🙂

                  Daten per IP websend kannst du von jedem Tasmota Gerät abfragen der die gleiche
                  StatusSNS/Energy/xxx............................ hat.

                  1 Reply Last reply Reply Quote 0
                  • RalfTh
                    RalfTh last edited by RalfTh

                    @ralla66 Ok, dann habe ich es richtig gemacht.

                    Allerdings stimmt der Inhalt nicht und diese Meldung scheint die Ursache zu sein:

                    18:34:19.588 MQT: stat/tasmota_B8D3E7/RESULT = {"WebSend":"Connect failed"}

                    Steht auch in meinem letzten Post in der Konsolenausgabe.
                    Gebe ich im Browser http://192.168.178.164/cm?cmnd=status 10 ein erhalte ich folgendes:
                    {"StatusSNS":{"Time":"2023-11-15T18:37:01","ENERGY":{"TotalStartTime":"2020-06-30T13:38:42","Total":0.556,"Yesterday":0.170,"Today":0.055,"Power":41,"ApparentPower":41,"ReactivePower":0,"Factor":1.00,"Voltage":229,"Current":0.181}}}

                    In der Konsole sieht es folgend aus:

                    18:38:48.972 MQT: tele/tasmota_B8D3E7/STATE = {"Time":"2023-11-15T18:38:48","Uptime":"0T12:01:26","UptimeSec":43286,"Heap":20,"SleepMode":"Dynamic","Sleep":50,"LoadAvg":19,"MqttCount":4,"POWER":"ON","Wifi":{"AP":1,"SSId":"Palatina","BSSId":"5C:49:79:55:9E:DC","Channel":4,"Mode":"11n","RSSI":82,"Signal":-59,"LinkCount":1,"Downtime":"0T00:00:03"}}
                    18:38:48.984 MQT: tele/tasmota_B8D3E7/SENSOR = {"Time":"2023-11-15T18:38:48","ENERGY":{"TotalStartTime":"2020-06-30T13:38:42","Total":0.558,"Yesterday":0.170,"Today":0.057,"Period":1,"Power":42,"ApparentPower":42,"ReactivePower":0,"Factor":1.00,"Voltage":229,"Current":0.183}}
                    18:38:50.972 SCR: performs "websend [192.168.178.164] /cm?cmnd=status 10"
                    18:38:56.176 MQT: stat/tasmota_B8D3E7/RESULT = {"WebSend":"Connect failed"}
                    18:38:56.184 MQT: stat/tasmota_B8D3E7/RESULT = {"Total":0}
                    18:38:56.191 MQT: stat/tasmota_B8D3E7/RESULT = {"Yesterday":0}
                    18:38:56.199 MQT: stat/tasmota_B8D3E7/RESULT = {"Today":0}
                    18:38:56.206 MQT: stat/tasmota_B8D3E7/RESULT = {"ApparentPower":0}
                    18:38:56.213 MQT: stat/tasmota_B8D3E7/RESULT = {"ReactivePower":0.00}
                    18:38:56.221 MQT: stat/tasmota_B8D3E7/RESULT = {"Power":0}
                    18:38:56.228 MQT: stat/tasmota_B8D3E7/RESULT = {"Voltage":0}
                    18:38:56.235 MQT: stat/tasmota_B8D3E7/RESULT = {"Current":0}
                    

                    In den ersten beiden Zeilen siehst du die JSON-Inhalte, aber ab Zeile 5 sind alle Werte 0??!!

                    Ich vermute das liegt am Connection failed in Zeile 4.

                    Ralla66 1 Reply Last reply Reply Quote 0
                    • Ralla66
                      Ralla66 Most Active @RalfTh last edited by Ralla66

                      @ralfth

                      ja richtig, vermute da ist was falsch in Zeile 45 beim send
                      Hattest du nicht 2 Gosund ? Dann nimm mal die andere IP

                      RalfTh 1 Reply Last reply Reply Quote 0
                      • RalfTh
                        RalfTh @Ralla66 last edited by

                        @ralla66 ich habe viele. Du meinst ich soll mal die Daten einer anderen abfragen und publishen?!

                        Ralla66 1 Reply Last reply Reply Quote 0
                        • Ralla66
                          Ralla66 Most Active @RalfTh last edited by Ralla66

                          @ralfth
                          ja zum testen ob websend rausgeht und ein Done kommt
                          Nachtrag: lösch mal den Kommentar
                          ; MQT: tasmota_Reserve2 = {"StatusSNS":{"Time":"2023-11-14T12:59:46","ENERGY":{"TotalStart...............................
                          nicht das die Zeile zu lang ist

                          sp111 15112023.jpg

                          RalfTh 1 Reply Last reply Reply Quote 0
                          • RalfTh
                            RalfTh @Ralla66 last edited by

                            @ralla66 OK, hier kommt eine DONE. allerdings werden die Die Werte nich ins Result geschrieben. Oder werden sie nicht richt gelesen?

                            18:57:45.317 SCR: performs "websend [192.168.178.151] /cm?cmnd=status 10"
                            18:57:45.391 MQT: stat/tasmota_B8D3E7/RESULT = {"WebSend":"Done"}
                            18:57:45.398 MQT: stat/tasmota_B8D3E7/RESULT = {"Total":0}
                            18:57:45.404 MQT: stat/tasmota_B8D3E7/RESULT = {"Yesterday":0}
                            18:57:45.408 MQT: stat/tasmota_B8D3E7/RESULT = {"Today":0}
                            18:57:45.412 MQT: stat/tasmota_B8D3E7/RESULT = {"ApparentPower":0}
                            18:57:45.416 MQT: stat/tasmota_B8D3E7/RESULT = {"ReactivePower":0.00}
                            18:57:45.421 MQT: stat/tasmota_B8D3E7/RESULT = {"Power":0}
                            18:57:45.425 MQT: stat/tasmota_B8D3E7/RESULT = {"Voltage":0}
                            18:57:45.429 MQT: stat/tasmota_B8D3E7/RESULT = {"Current":0}
                            

                            Hier läuft übrigens eine .bin 13.2.0 DE ganz normal von der Tasmota-Seite.

                            @ralfth sagte in Gosund SP111 mit Tasmota 13.2.0 Problem mit DP:

                            Die folgenden defines sind nicht mehr Bestandteil my_user_config.h

                            #define USE_SCRIPT_GLOBVARS
                            #define USE_SCRIPT_STATUS
                            #define USE_SCRIPT_STATUS
                            #define USE_SCRIPT_FULL_JSON_PARSER
                            #define USE_SCRIPT_JSON_EXPORT
                            #define USE_SCRIPT_WEB_DISPLAY
                            #define USE_SCRIPT_SERIAL
                            #define USE_SML_M

                            Damit steht es nicht in Zusammenhang. Hatte ich weiter oben schon geschrieben.

                            Ralla66 1 Reply Last reply Reply Quote 0
                            • Ralla66
                              Ralla66 Most Active @RalfTh last edited by

                              @ralfth sagte in Gosund SP111 mit Tasmota 13.2.0 Problem mit DP:

                              192.168.178.151

                              geprüft im Browser ?
                              Topic ist default ?

                              RalfTh 1 Reply Last reply Reply Quote 0
                              • RalfTh
                                RalfTh @Ralla66 last edited by

                                @ralla66 sagte in Gosund SP111 mit Tasmota 13.2.0 Problem mit DP:

                                @ralfth sagte in Gosund SP111 mit Tasmota 13.2.0 Problem mit DP:

                                192.168.178.151

                                geprüft im Browser ?
                                Topic ist default ?

                                Ja und Ja

                                Browser-Antwort:
                                {"StatusSNS":{"Time":"2023-11-15T19:10:25","ENERGY":{"TotalStartTime":"2020-01-10T16:35:26","Total":196.003,"Yesterday":0.483,"Today":0.467,"Power":84,"ApparentPower":104,"ReactivePower":61,"Factor":0.81,"Voltage":226,"Current":0.459}}}

                                06e576ca-8dc9-44af-85cd-0c45e0a28d1e-image.png

                                Ralla66 1 Reply Last reply Reply Quote 0
                                • Ralla66
                                  Ralla66 Most Active @RalfTh last edited by

                                  @ralfth

                                  den langen kommentar hast du gelöscht ?
                                  Telemetrie steht bei mir auf 10

                                  RalfTh 1 Reply Last reply Reply Quote 0
                                  • RalfTh
                                    RalfTh @Ralla66 last edited by RalfTh

                                    @ralla66 Beides Ja, allerdings immer noch:

                                    19:19:27.382 MQT: stat/tasmota_B8D3E7/RESULT = {"WebSend":"Connect failed"}

                                    Ich verstehe das nicht, wenn ich das im Webbrowser aufrufe funktioniert es doch!!!!

                                    Das ist allerdings neu:

                                    19:21:50.738 var not found: WebQuery#StatusSNS#ENERGY#Voltage
                                    19:21:50.740 Wert Volt 0.00
                                    19:21:50.742 var not found: WebQuery#StatusSNS#ENERGY#Current/1000
                                    19:21:50.743 Wert Current 0.00
                                    19:21:50.745 var not found: WebQuery#StatusSNS#ENERGY#Power
                                    19:21:50.746 Wert Power 0.00
                                    19:21:50.748 var not found: WebQuery#StatusSNS#ENERGY#Total
                                    19:21:50.750 Wert Total 0.00
                                    19:21:50.751 var not found: WebQuery#StatusSNS#ENERGY#Yesterday
                                    19:21:50.753 Wert Yesterday 0.00
                                    19:21:50.755 var not found: WebQuery#StatusSNS#ENERGY#Today
                                    19:21:50.756 Wert Today 0.00
                                    19:21:50.758 var not found: WebQuery#StatusSNS#ENERGY#ApparentPower
                                    19:21:50.759 Wert Apparent Power 0.00
                                    19:21:50.761 var not found: WebQuery#StatusSNS#ENERGY#ReactivePower
                                    19:21:50.763 Wert Reaktive Power 0.00
                                    
                                    Ralla66 1 Reply Last reply Reply Quote 0
                                    • Ralla66
                                      Ralla66 Most Active @RalfTh last edited by

                                      @ralfth

                                      Die folgenden defines sind nicht mehr Bestandteil my_user_config.h

                                      #define USE_SCRIPT_GLOBVARS
                                      #define USE_SCRIPT_STATUS
                                      #define USE_SCRIPT_STATUS
                                      #define USE_SCRIPT_FULL_JSON_PARSER

                                      der Parser zerlegt die Antwort vom websend der Anfrage in Today, Voltage usw.
                                      Der Parser wird zwingend benötigt.

                                      RalfTh 2 Replies Last reply Reply Quote 0
                                      • RalfTh
                                        RalfTh @Ralla66 last edited by

                                        @ralla66 OK, dann mach ich mich erst mal da dran un compiliere eine neue .bin

                                        Melde mich dann wieder. Und vielen Dank für Deine Unterstützung.

                                        Ralla66 1 Reply Last reply Reply Quote 0
                                        • RalfTh
                                          RalfTh @Ralla66 last edited by

                                          @ralla66 Dieses define steht in der my_user_config.h ??

                                          1 Reply Last reply Reply Quote 0
                                          • Ralla66
                                            Ralla66 Most Active @RalfTh last edited by

                                            @ralfth

                                            und nimm bitte alle define USE_xxxxx
                                            Auf git liefen meine .bin auch nicht,erst die mit Tasmocompiler erstellten
                                            liefen dann. Probiers mal.

                                            RalfTh 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            589
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            4
                                            88
                                            6005
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo