      servus,
      Ich habe meinen Sonoff TH per MQTT in den iOBroker eingebunden.

      Leider wird dort der Temperaturwert nicht angezeigt.

      wer kann helfen?

      mfg

      orfix
      sonof.txtiobroker.JPG

      Ralla66 haselchen 2 Replies Last reply Reply Quote 0
      • Ralla66
        Ralla66 Most Active @orfix last edited by Ralla66

        @orfix sagte in keine Temperatur werte per MQTT im Iobroker:

        Sonoff TH

        Tasmota Konsole zeigt was an ?
        Telemetrieperiode Tasmota hat welchen Wert ?

        1 Reply Last reply Reply Quote 0
        • haselchen
          haselchen Most Active @orfix last edited by

          @orfix

          Welchen Adapter hast du benutzt ?
          Sonoff Adapter
          MQTT Adapter ?

          Welchen Port ?

          1 Reply Last reply Reply Quote 0
          • O
            orfix last edited by

            @haselchen
            servus,

            danke für die hilfe, daten werden ja gesendet also muss der port passen.
            Es wird aber keine temperatur übertragen?
            ausgabe konsole ist im anhang.

            mfg

            orfix

            haselchen 1 Reply Last reply Reply Quote 0
            • haselchen
              haselchen Most Active @orfix last edited by haselchen

              @orfix

              Trotzdem hast Du meine wichtigste Frage nicht beantwortet .

              Zudem, hast Du beide Adapter aktiv ?
              Unterschiedliche Ports?

              Die Sensoren habe ich gestern verbaut mit Tasmota.
              Sollte dir also helfen können 😉

              O 1 Reply Last reply Reply Quote 0
              • O
                orfix @haselchen last edited by orfix

                @haselchen

                servus,

                danke für die hilfe, bin kein mqtt fachmann, aber einige sonoffs laufen aber schon.
                port ist 1084
                es wird auch was übertragen z.B die uhrzeit?
                siehe anhang
                sonof_th16_frostschutz2.JPG

                konsole_ausgabe1.txt

                mfg

                orfix

                haselchen Homoran 2 Replies Last reply Reply Quote 0
                • haselchen
                  haselchen Most Active @orfix last edited by haselchen

                  @orfix

                  Das hat mit Fachmann nichts zu tun, wenn man die Fragen immer und immer wieder nicht beantwortet.
                  Immerhin hast Du es ja anscheinend geschafft die Sensoren zu installieren.

                  1 Reply Last reply Reply Quote 0
                  • Homoran
                    Homoran Global Moderator Administrators @orfix last edited by

                    @orfix sagte in keine Temperatur werte per MQTT im Iobroker:

                    siehe anhang

                    bitte hier in code-tags posten!
                    eine Datei kann und will nicht jeder öffnen

                    O 2 Replies Last reply Reply Quote 0
                    • O
                      orfix @Homoran last edited by

                      Hier die Konsolenausgabe:

                      17:21:11.441 MQT: tele/tasmota_329E75/STATE = {"Time":"2024-01-14T17:21:11","Uptime":"1T03:21:15","UptimeSec":98475,"Heap":26,"SleepMode":"Dynamic","Sleep":50,"LoadAvg":19,"MqttCount":1,"POWER":"OFF","Wifi":{"AP":2,"SSId":"FRITZ!Box 4040 IV","BSSId":"30:D3:2D:1A:F7:40","Channel":1,"Mode":"11n","RSSI":100,"Signal":-38,"LinkCount":1,"Downtime":"0T00:00:03"}}
                      17:21:11.449 MQT: tele/tasmota_329E75/SENSOR = {"Time":"2024-01-14T17:21:11","DS18B20":{"Id":"3C82F648F691","Temperature":-1.1},"TempUnit":"C"}
                      17:21:21.581 MQT: tele/tasmota_329E75/STATE = {"Time":"2024-01-14T17:21:21","Uptime":"1T03:21:25","UptimeSec":98485,"Heap":26,"SleepMode":"Dynamic","Sleep":50,"LoadAvg":23,"MqttCount":1,"POWER":"OFF","Wifi":{"AP":2,"SSId":"FRITZ!Box 4040 IV","BSSId":"30:D3:2D:1A:F7:40","Channel":1,"Mode":"11n","RSSI":100,"Signal":-38,"LinkCount":1,"Downtime":"0T00:00:03"}}
                      17:21:21.588 MQT: tele/tasmota_329E75/SENSOR = {"Time":"2024-01-14T17:21:21","DS18B20":{"Id":"3C82F648F691","Temperature":-1.2},"TempUnit":"C"}
                      
                      MartinP 1 Reply Last reply Reply Quote 0
                      • O
                        orfix @Homoran last edited by

                        @homoran
                        danke für den Hinweis

                        O 1 Reply Last reply Reply Quote 0
                        • MartinP
                          MartinP @orfix last edited by MartinP

                          @orfix Steht da Json im Datenpunkt "SENSOR", wenn Du Ihn öffnest? ...

                          Dann könntest Du mit einem Alias die Temperatur-Werte herauspflücken...

                          14888eb4-ad50-4309-b888-2d514126d25a-grafik.png

                          efb0c2cb-7306-45f8-9f8a-55454a676bda-grafik.png

                          1 Reply Last reply Reply Quote 0
                          • O
                            orfix @orfix last edited by

                            @orfix sonoff_mqtt1.jpg

                            B Homoran 2 Replies Last reply Reply Quote 0
                            • B
                              berndsolar13 @orfix last edited by

                              @orfix
                              ich schicke meine Temp Werte an den Sonoff Adapter, der splittet den Json String automatisch auf 😉

                              1 Reply Last reply Reply Quote 0
                              • Homoran
                                Homoran Global Moderator Administrators @orfix last edited by

                                @orfix sagte in keine Temperatur werte per MQTT im Iobroker:

                                @orfix sonoff_mqtt1.jpg

                                interne IP Adressen brauchst du nicht schwärzen. auch nicht mit rot.
                                Den Usernamen hätte ich ja noch verstanden.

                                Was steckt denn hinter der erröteten IP?

                                O 1 Reply Last reply Reply Quote 0
                                • O
                                  orfix @Homoran last edited by

                                  @homoran
                                  mit dem original Sonoff adapter läuft es jetzt.
                                  4fach_temp.JPG

                                  mfg
                                  orfix

                                  1 Reply Last reply Reply Quote 0
                                  • First post
                                    Last post

                                  Support us

                                  ioBroker
                                  Community Adapters
                                  Donate

                                  776
                                  Online

                                  31.7k
                                  Users

                                  79.9k
                                  Topics

                                  1.3m
                                  Posts

                                  6
                                  15
                                  412
                                  Loading More Posts
                                  • Oldest to Newest
                                  • Newest to Oldest
                                  • Most Votes
                                  Reply
                                  • Reply as topic
                                  Log in to reply
                                  Community
                                  Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                  The ioBroker Community 2014-2023
                                  logo