    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    • Monatsrückblick - April 2025

    Test Adapter Pylontech v0.0.10

    This topic has been deleted. Only users with topic management privileges can see it.
    • PLCHome 0
      PLCHome 0 Developer @PLCHome 0 last edited by

      @plchome-0 ich mache gleich mal eine 0.0.10 die sollte das dann können

      B 1 Reply Last reply Reply Quote 0
      • derAuge
        derAuge @l1berty last edited by

        @l1berty
        Den Waveshare RS232/485/422 to RJ45 Ethernet Module, TCP/IP to Serial habe ich mir gerade bestellt.
        e2caac27-5c21-4c0d-ae78-ecdffe9c34bc-image.png

        nun fertige ich gerade das Anschlusskabel.

        7d9886f9-61d3-4d12-81cd-d3f9e2802cd3-image.png
        Pin1
        Pin2
        Pin3 => 232TX
        Pin4
        Pin5
        Pin6 => 232RX
        Pin7
        Pin8 => GND

        d3b024e3-5765-41bb-926b-062a8ca2fd63-image.png

        Pin2 => RXD
        Pin3 => TXD
        Pin5 => GND

        Frage: Müssen die Anschlüsse gekreuzt werden? (232TX-RXD) (232RX-TXD) (GND-GND)
        Oder eine 1:1 Verbindung?

        Wenn die Lieferung am Montag kommt, kann ich mit dem Testen unterstützen.
        Es sollen 4x UC3000 ausgelesen werden
        38fa7ed5-73c3-4218-b66c-fb9e1ceb4237-image.png

        Gruß
        Jürgen

        PLCHome 0 1 Reply Last reply Reply Quote 1
        • PLCHome 0
          PLCHome 0 Developer @derAuge last edited by PLCHome 0

          @derauge
          Das Bild findest du zusammen mit dem Pinout in der readme.

          c4b9bbaa-fecc-497c-89cd-9506ae5e5321-image.png

          Die Geräte haben einen Stecker, daher muss es an der Kupplung so wie in der Readme angeschlossen werden.
          Bei Kupplungen an den Geräten und Steckern am Kabel müssen RX und TX getaucht werden.

          US3000 sollten einwandfrei funktionieren. Bitte nur den Ersten im Stack auslesen.

          derAuge 1 Reply Last reply Reply Quote 1
          • derAuge
            derAuge @PLCHome 0 last edited by

            @plchome-0

            super,
            habe nun ein Kabel angefertigt.
            Wie kann ich es testen?
            Habe einen Digitus USB-RS232-Adapter und ein Terminalprogramm.
            mit welcher Baud-Rate und mit welchem Befehl kann ich etwas aus der Konsole locken?

            Gruß
            Jürgen

            PLCHome 0 B 2 Replies Last reply Reply Quote 0
            • PLCHome 0
              PLCHome 0 Developer @derAuge last edited by

              @derauge

              mit welcher Baud-Rate und mit welchem Befehl kann ich etwas aus der Konsole locken?

              115200
              Das Problem ist, das er als Zeilenende gerne Cr nicht LF oder Cr LF hat.

              derAuge 1 Reply Last reply Reply Quote 0
              • derAuge
                derAuge @PLCHome 0 last edited by

                Habe dann erst mal meine "mobile" Installation direkt an das neue Kabel angeschlosse

                crw--w---- 1 root tty       4,  9  4. Mär 06:52 /dev/tty9
                lrwxrwxrwx 1 root root          7  4. Mär 06:52 /dev/ttyLaCrosse -> ttyUSB0
                crw------- 1 root root      5,  3  4. Mär 06:52 /dev/ttyprintk
                crw-rw---- 1 root dialout 188,  0  4. Mär 06:52 /dev/ttyUSB0
                crw-rw---- 1 root dialout 188,  1  4. Mär 06:52 /dev/ttyUSB1
                auge@RPi4-1:~ $
                auge@RPi4-1:~ $
                auge@RPi4-1:~ $
                auge@RPi4-1:~ $ ls -l /dev/serial/by-id
                insgesamt 0
                lrwxrwxrwx 1 root root 13  4. Mär 06:52 usb-FTDI_FT232R_USB_UART_A5064E7V-if00-port0 -> ../../ttyUSB                         1
                lrwxrwxrwx 1 root root 13  4. Mär 06:52 usb-SHK_JeeLink_LaCrosse-if00-port0 -> ../../ttyUSB0
                auge@RPi4-1:~ $
                auge@RPi4-1:~ $
                
                

                Nach Installation das Adapters habe ich verschiedene "Lokaler Gerätepfad" getestet.

                pylontech.0
                2024-03-04 07:23:19.197	error	Error: Error: No such file or directory, cannot open /dev/serial/by-id/usb-FTDI_FT232R_USB_UART_A5064E7V-if00-port0
                pylontech.0
                2024-03-04 07:18:19.211	error	Error: Error: No such file or directory, cannot open /dev/serial/by-id/usb-FTDI_FT232R_USB_UART_A5064E7V-if00-port0
                pylontech.0
                2024-03-04 07:18:19.156	info	starting. Version 0.0.10 in /opt/iobroker/node_modules/iobroker.pylontech, node: v18.19.0, js-controller: 5.0.19
                pylontech.0
                2024-03-04 07:18:13.842	info	Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                pylontech.0
                2024-03-04 07:18:13.840	info	terminating
                pylontech.0
                2024-03-04 07:18:13.837	info	Got terminate signal TERMINATE_YOURSELF
                pylontech.0
                2024-03-04 07:15:18.790	error	Error: Error: No such file or directory, cannot open ttyUSB1
                pylontech.0
                2024-03-04 07:10:18.803	error	Error: Error: No such file or directory, cannot open ttyUSB1
                pylontech.0
                2024-03-04 07:10:18.751	info	starting. Version 0.0.10 in /opt/iobroker/node_modules/iobroker.pylontech, node: v18.19.0, js-controller: 5.0.19
                pylontech.0
                2024-03-04 07:10:13.643	info	Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                pylontech.0
                2024-03-04 07:10:13.641	info	terminating
                pylontech.0
                2024-03-04 07:10:13.638	info	Got terminate signal TERMINATE_YOURSELF
                pylontech.0
                2024-03-04 07:08:11.550	error	Error: Error: No such file or directory, cannot open /dev/ttyUSB1
                pylontech.0
                2024-03-04 07:08:11.500	info	starting. Version 0.0.10 in /opt/iobroker/node_modules/iobroker.pylontech, node: v18.19.0, js-controller: 5.0.19
                pylontech.0
                2024-03-04 07:08:06.937	info	terminating
                pylontech.0
                2024-03-04 07:08:06.434	info	Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                pylontech.0
                2024-03-04 07:08:06.432	info	terminating
                pylontech.0
                2024-03-04 07:08:06.430	info	Got terminate signal TERMINATE_YOURSELF
                pylontech.0
                2024-03-04 07:07:09.155	error	"path" is not defined:
                pylontech.0
                2024-03-04 07:07:09.121	info	starting. Version 0.0.10 in /opt/iobroker/node_modules/iobroker.pylontech, node: v18.19.0, js-controller: 5.0.19
                

                Nun gibt es zwei Möglichkeiten:
                1.) Das Kabel ist falsch gebaut
                2.) Die Pylontech spricht nicht mit uns

                Werde dann erst noch mal das Kabel durchmessen müssen,
                Oder habt ihr noch eine weitere Idee?

                Gruß
                Jürgen

                1 Reply Last reply Reply Quote 0
                • B
                  bios123 @PLCHome 0 last edited by

                  @plchome-0 Kurzes Feedback: v.0.0.10 läuft gut und macht bis jetzt keinen Ärger mit der Pytes-V5. Ich habe das logging allerdings auf debug zurückgeschraubt, sehe also nicht mehr alles. Es gab keinen Timeout mehr. Wie sieht es denn mit soh bzw stat aus? Bringst du noch eine Update oder ist das schon integriert? Hatte im Hinterkopf erstmal die Timeouts bekämpfen und dann den Rest. Die einzige Meldung die immer kommt:

                  debug | Search can't be optimized because wildcard not at the end, fallback to keys!: function(doc) { if (doc.type === 'state') emit(doc._id, doc) }
                  

                  Vielleicht sollte man in der Adapterkonfig nochmal hervorheben welches Modell für welchen Battery-Typ passt oder den Selektor einen weiteren Eintrag verpassen. Dokumentation lesen macht halt lange nicht jeder.

                  1 Reply Last reply Reply Quote 0
                  • B
                    bios123 @derAuge last edited by

                    @derauge Ich mache das in der Regel auf einem Linux mit screen. Damit kannst du direkt sehen ob was kommt. Zum Beispiel

                    screen /dev/ttyUSB0 115200 natürlich mit deinem Schnitstellepfad ersetzen (serial/by-id Pfad oder udev Regel nutzen macht Sinn).

                    1 Reply Last reply Reply Quote 1
                    • derAuge
                      derAuge last edited by

                      Heute wieder einen Schritt weiter....

                      hatte meinen Fehler im Adapterkabel gefunden... Dummheit von mir.
                      Dann habe ich den Tipp von @bios123 befolgt

                      screen /dev/ttyUSB1 115200
                      

                      Dadurch weiß ich nun, dass mein Adapterkabel funktioniert 🙂

                      Nun habe ich "/dev/ttyUSB1" in die Adapter eingetragen 😞

                      pylontech.0
                      2024-03-04 21:49:16.557	error	Error: Error: No such file or directory, cannot open /dev/ttyUSB1
                      

                      Danach habe ich den ersten USB-Anschluss frei gemacht und nur den USB->RS232 mit dem Adapterkabel angeschlossen.
                      Nun liegt der USB-Adapter auf "ttyUSB0"
                      92beaaa6-f6c7-4855-85fd-342e66532f24-image.png
                      nun funktionier der Adapter und die Pylontech wird ausgelesen

                      
                      pylontech.0
                      2024-03-04 22:30:33.695	debug	Search can't be optimized because wildcard not at the end, fallback to keys!: function(doc) { if (doc.type === 'state') emit(doc._id, doc) }
                      
                      pylontech.0
                      2024-03-04 22:29:01.495	debug	{"command":"getDevices","message":"{}","from":"system.adapter.admin.0","callback":{"message":"{}","id":8,"ack":false,"time":1709587741491},"_id":75762725}
                      
                      pylontech.0
                      2024-03-04 22:25:33.691	debug	Search can't be optimized because wildcard not at the end, fallback to keys!: function(doc) { if (doc.type === 'state') emit(doc._id, doc) }
                      
                      pylontech.0
                      2024-03-04 22:20:33.691	debug	Search can't be optimized because wildcard not at the end, fallback to keys!: function(doc) { if (doc.type === 'state') emit(doc._id, doc) }
                      
                      pylontech.0
                      2024-03-04 22:15:33.737	debug	Search can't be optimized because wildcard not at the end, fallback to keys!: function(doc) { if (doc.type === 'state') emit(doc._id, doc) }
                      
                      pylontech.0
                      2024-03-04 22:10:33.903	debug	Search can't be optimized because wildcard not at the end, fallback to keys!: function(doc) { if (doc.type === 'state') emit(doc._id, doc) }
                      
                      pylontech.0
                      2024-03-04 22:05:33.758	debug	Search can't be optimized because wildcard not at the end, fallback to keys!: function(doc) { if (doc.type === 'state') emit(doc._id, doc) }
                      
                      pylontech.0
                      2024-03-04 22:05:31.263	info	starting. Version 0.0.10 in /opt/iobroker/node_modules/iobroker.pylontech, node: v18.19.0, js-controller: 5.0.19
                      

                      die Debug-Meldungen sind sicher bekannt.

                      Was ich noch getestet habe

                      auge@RPi4-1:~ $ ls -l /dev/serial/by-id
                      insgesamt 0
                      lrwxrwxrwx 1 root root 13  4. Mär 21:46 usb-FTDI_FT232R_USB_UART_A5064E7V-if00-port0 -> ../../ttyUSB0
                      auge@RPi4-1:~ $
                      

                      den Wert in die Config einzutragen:
                      a9109eae-59c3-447e-8821-07f0a70c06cb-image.png

                      pylontech.0
                      2024-03-04 22:35:43.806	error	Error: Error: No such file or directory, cannot open /dev/serial/by-id/usb-FTDI_FT232R_USB_UART_A5064E7V-if00-port0
                      
                      pylontech.0
                      2024-03-04 22:35:43.756	info	starting. Version 0.0.10 in /opt/iobroker/node_modules/iobroker.pylontech, node: v18.19.0, js-controller: 5.0.19
                      

                      Für mich sieht es so aus, dass nur die Konfiguration mit "/dev/ttyUSB0" funktioniert

                      Gruß
                      Jürgen

                      1 Reply Last reply Reply Quote 0
                      • B
                        bios123 last edited by

                        @PLCHome-0 Kann es sein das wir hier noch ein RegEx Problem haben? Irgendwie passt da was nicht. Die Bezeichnungen der Spalte sehen verschoben aus und die Werte teilweise auch. Die Daten holt der Adapter jetzt stabil aus dem Pack, jetzt brauchen wir wohl noch Feinschliff.

                        1e991e4b-242c-416d-a861-337b9d8427a6-image.png

                        9cad6e10-881e-4151-b35c-b31907004476-image.png

                        PLCHome 0 1 Reply Last reply Reply Quote 0
                        • PLCHome 0
                          PLCHome 0 Developer @bios123 last edited by

                          @bios123 schick mir bitte noch mal eine Datei von bat 1. Ist irgendwie komisch...

                          B 1 Reply Last reply Reply Quote 0
                          • B
                            bios123 @PLCHome 0 last edited by bios123

                            @plchome-0 Hab nochmal alle Daten gelöscht um zu prüfen ob direkt wieder das gleich Problem auftritt, aber dem ist nicht so. Ich werde es beobachten und dir eine Datei schicken.

                            14e217b1-22bb-4509-903a-76585e1b8e0c-image.png

                            B 1 Reply Last reply Reply Quote 0
                            • B
                              bios123 @bios123 last edited by

                              @PLCHome-0 Hat nicht lange gedauert...

                              e1c0a89a-9797-4d2b-bb42-9d988dcdd133-image.png

                              PLCHome 0 1 Reply Last reply Reply Quote 0
                              • H
                                hominidae @PLCHome 0 last edited by hominidae

                                @plchome-0 said in Test Adapter Pylontech v0.0.10:

                                Ich hatte mir zu Anfang in Node-Red etwas zusammengebastelt.
                                Das habe ich jetzt einfach in einen Adapter gegossen.

                                ...wirklich sehr interessantes Projekt!
                                Da ich iobroker nicht einsetze, die vorsichtige Frage, ob es auch eine "Node-Red-only" Version gibt?

                                greetz,
                                hominidae

                                PLCHome 0 1 Reply Last reply Reply Quote 0
                                • PLCHome 0
                                  PLCHome 0 Developer @hominidae last edited by

                                  @hominidae ich hatte hier mal etwas gebastelt:

                                  https://forum.iobroker.net/topic/67799/pylontech-mit-nodered-in-den-iobroker-geschlossen

                                  H 1 Reply Last reply Reply Quote 1
                                  • PLCHome 0
                                    PLCHome 0 Developer @bios123 last edited by PLCHome 0

                                    @bios123 sagte in Test Adapter Pylontech v0.0.10:

                                    @PLCHome-0 Hat nicht lange gedauert...

                                    Ich kann das aktuell nicht nachvollziehen. Hattest du die 0.0.10 installiert?
                                    Ich hab die jetzt mal als stabil gekennzeichnet. Mit den Daten, die im Repro liegen, läuft es bei mir. Ich will ja nicht ausschließen, dass es Konstellationen gibt, in denen es falsch läuft, aber ich hab hier nichts gesehen.

                                    Samson71 1 Reply Last reply Reply Quote 0
                                    • Samson71
                                      Samson71 Global Moderator @PLCHome 0 last edited by

                                      @plchome-0 sagte in Test Adapter Pylontech v0.0.10:

                                      Ich kann das aktuell nicht nachvollziehen. Hattest die die 0.0.10 installiert?

                                      Sicherlich nicht. Er hat nach eigenem Bekunden ja nicht mal ioBroker im Einsatz. Deswegen fragt er ja nach Node-Red "pur".

                                      PLCHome 0 1 Reply Last reply Reply Quote 0
                                      • PLCHome 0
                                        PLCHome 0 Developer @Samson71 last edited by PLCHome 0

                                        @samson71
                                        @hominidae ==> kein ioBroker
                                        @bios123 ==> ioBroker und Pytes V5. Der Pytes V5 verhält sich wie die ganz alten Pylontechs und macht Probleme bei den Regex....

                                        Aber Danke: es muss natürlich "Hattest du die" und nicht "Hattest die die" lauten 🙂

                                        Samson71 J 2 Replies Last reply Reply Quote 0
                                        • Samson71
                                          Samson71 Global Moderator @PLCHome 0 last edited by

                                          @plchome-0
                                          Sorry, habe die User verwechselt. Die Schreibkorrektur war gar nicht meine Intention 😉

                                          1 Reply Last reply Reply Quote 0
                                          • H
                                            hominidae @PLCHome 0 last edited by

                                            @plchome-0 danke für die schnelle Reaktion und den Link..das schaue ich mir an....ich habe 10x US3000C am einem 3ph Victron System am Start.

                                            ...hast Du auch irgendwo Infos, wie du die Daten nach influx schiebst und mit Grafana wieder visualisiert hast?
                                            Da ich den TIG-Stack nutze würde ich die Batterie-Daten eher nach mqtt konvertieren um in der Toolchain zu bleiben.

                                            PLCHome 0 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            588
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            27
                                            204
                                            22920
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo