    Node-Red - Shelly PlusPlugS - Mqtt Node-Red Dashboard

    This topic has been deleted. Only users with topic management privileges can see it.
    • H
      Hape1 @mickym last edited by

      @mickym ... den Adapter im iobroker hatte ich schon deinstalliert., da sollte nix mehr sein.

      H 1 Reply Last reply Reply Quote 0
      • H
        Hape1 @Hape1 last edited by

        @mickym Ich bastel immer noch an meinem flow. Könntest Du mir bitte kurz erklären, was dieser Change-node macht:

        Bildschirmfoto 2024-04-13 um 13.56.15.png

        mickym 1 Reply Last reply Reply Quote 0
        • mickym
          mickym Most Active @Hape1 last edited by mickym

          @hape1 sie begrenzt auf werte zwischen 10 und 1600 und skaliert. ich würde empfehlen das gleich zu setzen ein- und ausgang oder du nimmst eine switch node und passt das manuell an. Da steuerst du selbst was wann passiert.

          H 1 Reply Last reply Reply Quote 0
          • H
            Hape1 @mickym last edited by

            @mickym ... verstehe ich leider nicht, könntest Du das bitte an dem Node beispielhaft darstellen?

            mickym 1 Reply Last reply Reply Quote 0
            • mickym
              mickym Most Active @Hape1 last edited by

              @hape1 eine switch node?

              1 Reply Last reply Reply Quote 0
              • mickym
                mickym Most Active last edited by

                So und zu der range Node - mach Dir halt ein einfaches Beispiel .

                Nehmen wir mal an Du hast beides auf 0-100 eingestellt:

                5cb33d9e-2849-4ecf-b9c1-c9ae873bc918-image.png

                Alles was unter 0 ist - ergibt 0 - alles was über 100 ist - 100 und dazwischen den Wert den die payload hat.

                Skalierst Du nun - also Eingangsbereich 0-10 und Ausgangsbereich 0-100

                9ea44e9c-c7e1-427a-adcf-8e2158496413-image.png

                Sprich jeder Eingangswert wird mit 10 multipliziert - da 0-10 einem Ausgang von 0-100 entspricht. Also Wertebereich Ausgang/ Wertebereich Eingang.

                Umgekehrt wenn Du Eingang 0-100 und Ausgang 0-10 wird alles mal 0,1 mutlipliziert:

                cbea0053-e716-49e6-9fc6-2d857d0835cf-image.png

                mickym 1 Reply Last reply Reply Quote 0
                • mickym
                  mickym Most Active @mickym last edited by

                  Sprich bei Deinen krummen Werten entspricht jeder Eingangsdatenpunkt 1,0034 Ausgangsdatenpunkten.

                  1 Reply Last reply Reply Quote 0
                  • mickym
                    mickym Most Active last edited by mickym

                    Ansonsten nimmst Du wie gesagt eine Switch Node und setzt für die Wertebereiche unterschiedliche Ausgänge, die Du dann verschieden weiter bearbeitest.

                    d576553f-edbc-472c-be83-f8052432242a-image.png

                    Hier alles zum Ausprobieren:

                    [{"id":"e0fbb6ef3bc1293e","type":"debug","z":"289f539dcc33814e","name":"debug 45","active":true,"tosidebar":true,"console":false,"tostatus":false,"complete":"false","statusVal":"","statusType":"auto","x":560,"y":7320,"wires":[]},{"id":"6cf119bfcb698c9a","type":"range","z":"289f539dcc33814e","minin":"0","maxin":"100","minout":"0","maxout":"10","action":"clamp","round":false,"property":"payload","name":"","x":350,"y":7320,"wires":[["e0fbb6ef3bc1293e"]]},{"id":"e9ae12baa668f5b7","type":"inject","z":"289f539dcc33814e","name":"","props":[{"p":"payload"},{"p":"topic","vt":"str"}],"repeat":"","crontab":"","once":false,"onceDelay":0.1,"topic":"","payload":"-5","payloadType":"num","x":150,"y":7260,"wires":[["6cf119bfcb698c9a"]]},{"id":"8eb496d7d9fcb752","type":"inject","z":"289f539dcc33814e","name":"","props":[{"p":"payload"},{"p":"topic","vt":"str"}],"repeat":"","crontab":"","once":false,"onceDelay":0.1,"topic":"","payload":"50","payloadType":"num","x":150,"y":7340,"wires":[["6cf119bfcb698c9a"]]},{"id":"bb2a6d559569cc1b","type":"inject","z":"289f539dcc33814e","name":"","props":[{"p":"payload"},{"p":"topic","vt":"str"}],"repeat":"","crontab":"","once":false,"onceDelay":0.1,"topic":"","payload":"5","payloadType":"num","x":150,"y":7300,"wires":[["6cf119bfcb698c9a"]]},{"id":"3b168128bcbcd820","type":"inject","z":"289f539dcc33814e","name":"","props":[{"p":"payload"}],"repeat":"","crontab":"","once":false,"onceDelay":0.1,"topic":"","payload":"150","payloadType":"num","x":150,"y":7380,"wires":[["6cf119bfcb698c9a"]]},{"id":"3848516721d2de69","type":"switch","z":"289f539dcc33814e","name":"","property":"payload","propertyType":"msg","rules":[{"t":"lt","v":"10","vt":"num"},{"t":"btwn","v":"10","vt":"num","v2":"1500","v2t":"num"},{"t":"gt","v":"1500","vt":"num"}],"checkall":"true","repair":false,"outputs":3,"x":750,"y":7480,"wires":[[],[],[]]}]
                    

                    H 1 Reply Last reply Reply Quote 0
                    • H
                      Hape1 @mickym last edited by

                      @mickym Hi, ich bräuchte noch mal Deine Hilfe:

                      Ich möchte einmal am Tag den WR restarten. Dazu hätte ich folgenden Datenpunkt zur Verfügung:

                      Bildschirmfoto 2024-04-17 um 17.33.44.png

                      Bildschirmfoto 2024-04-17 um 17.34.01.png

                      Welche nodes müßte ich hierfür verwenden?

                      mickym 1 Reply Last reply Reply Quote 0
                      • mickym
                        mickym Most Active @Hape1 last edited by mickym

                        @hape1 Du nimmst einfach eine Inject Node setzt die Eigenschaft payload und den booleschen Wert true und schickst diesen über eine iobroker Out Node an diesen Datenpunkt. Das topic brauchst nicht, da Du es ja fix in die iobroker out Node einträgst.

                        Bei der Wiederholung trägst Du ein, wann die Inject Node von sich aus das true senden soll.

                        1 Reply Last reply Reply Quote 0
                        • First post
                          Last post

                        Support us

                        ioBroker
                        Community Adapters
                        Donate

                        892
                        Online

                        31.7k
                        Users

                        79.7k
                        Topics

                        1.3m
                        Posts

                        3
                        187
                        14772
                        Loading More Posts
                        • Oldest to Newest
                        • Newest to Oldest
                        • Most Votes
                        Reply
                        • Reply as topic
                        Log in to reply
                        Community
                        Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                        The ioBroker Community 2014-2023
                        logo