    NOUS A1Z Steckdose Energiewert auf 0 setzten

    This topic has been deleted. Only users with topic management privileges can see it.
    • Marc Berg
      Marc Berg Most Active @schrup21 last edited by Marc Berg

      gelöscht

      1 Reply Last reply Reply Quote 0
      • 123brokerei
        123brokerei last edited by

        Hi, hat da inzwischen jemand eine Lösung für den Zigbee-Adapter parat?

        Asgothian 1 Reply Last reply Reply Quote 0
        • Asgothian
          Asgothian Developer @123brokerei last edited by

          @123brokerei sagte in NOUS A1Z Steckdose Energiewert auf 0 setzten:

          Hi, hat da inzwischen jemand eine Lösung für den Zigbee-Adapter parat?

          Nein. Prinzipiell sollte es gehen über den developer tab den Wert zurück zu setzen, allerdings gibt es da aktuell einen Bug der den Developer tab stört. Ein issue ist bereits aufgemacht. Sobald das gelöst ist kann der Wert über einen funktionsaufruf aus einem Skript zurück gesetzt werden.

          A.

          Ro75 B 2 Replies Last reply Reply Quote 0
          • Ro75
            Ro75 @Asgothian last edited by

            @asgothian Das klingt sehr gut. Kann es dann dazu auch ggfs. ein Code-Schnippsel geben? Das wäre super. Schonmal vielen Dank.

            Ro75.

            Asgothian 1 Reply Last reply Reply Quote 0
            • Asgothian
              Asgothian Developer @Ro75 last edited by

              @ro75 sagte in NOUS A1Z Steckdose Energiewert auf 0 setzten:

              @asgothian Das klingt sehr gut. Kann es dann dazu auch ggfs. ein Code-Schnippsel geben? Das wäre super. Schonmal vielen Dank.

              Ro75.

              Wird es geben.

              A.

              MartinP 1 Reply Last reply Reply Quote 1
              • MartinP
                MartinP @Asgothian last edited by

                Hmm - wieso das Problem nicht mit Iobroker lösen?
                Den "Nullpunkt" Zählerstand in einer Userdata Variable speichern. Eine weitere Variable hält die Differenz aus aktuellem Zählerstand der Dose und Nullpunkt- Zählerstand.

                So spielt das fehlende "Nullen" des Zählerstandes der Steckdose keine Rolle

                Ro75 1 Reply Last reply Reply Quote 0
                • Ro75
                  Ro75 @MartinP last edited by Ro75

                  @martinp so mache ich das bereits. Dennoch interessiert es mich, wie ich diese Steckdose auf "0" (Verbrauch) setzen kann.

                  Ro75.

                  1 Reply Last reply Reply Quote 0
                  • B
                    bastler @Asgothian last edited by

                    @asgothian Moin, wurde der Bug inzwischen behoben, damit ein Reset der Energiewerte durchgeführt werden kann?

                    A Asgothian 3 Replies Last reply Reply Quote 0
                    • A
                      AVO2705 @bastler last edited by

                      @bastler schon mal versucht in der Konsole der Tasmota App folgenden Befehl einzugeben:
                      Energytoday 0
                      Energyyesterday 0
                      Energytotal 0

                      Marc Berg 1 Reply Last reply Reply Quote 0
                      • Asgothian
                        Asgothian Developer @bastler last edited by Asgothian

                        @bastler sagte in NOUS A1Z Steckdose Energiewert auf 0 setzten:

                        @asgothian Moin, wurde der Bug inzwischen behoben, damit ein Reset der Energiewerte durchgeführt werden kann?

                        Die aktuelle Version auf github hat den Bug nicht mehr

                        1 Reply Last reply Reply Quote 0
                        • Asgothian
                          Asgothian Developer @schrup21 last edited by

                          @schrup21 sagte in NOUS A1Z Steckdose Energiewert auf 0 setzten:

                          @ro75 @Marc-Berg
                          Hey!
                          Also ich kann bestätigen, dass die Prozedur funktioniert, gerade bei mir getestet. Dauert nur etwas, bis die Steckdose 0 ausgiebt.
                          vorher:
                          2023-09-03 14:59:05MQTT publish: topic 'zigbee2mqtt/NOUS ', payload '{"child_lock":"UNLOCK","current":0,"energy":26.97,"indicator_mode":"off/on","linkquality":124,"power":0,"power_outage_memory":"restore","state":"ON","update":{"installed_version":192,"latest_version":192,"state":"idle"},"update_available":false,"voltage":235}'
                          nachher:
                          info 2023-09-03 14:59:05MQTT publish: topic 'zigbee2mqtt/NOUS ', payload '{"child_lock":"UNLOCK","current":0,"**energy":0,"**indicator_mode":"off/on","linkquality":124,"power":0,"power_outage_memory":"restore","state":"ON","update":{"installed_version":192,"latest_version":192,"state":"idle"},"update_available":false,"voltage":235}'
                          info

                          Cluster hab ich 0x0000 angegeben (weil das so unter "example" angegeben ist).

                          Zigbee2MQTT-Version 1.33.0
                          Coordinator-Typ EZSP v8
                          Coordinator-Version 6.10.3.0 build 297

                          @Marc-Berg Danke für die Info! Hab nach Verbrauch Zurücksetzen gesucht und bin dank dir sofort fündig geworden.

                          Kannst du bitte posten was genau du im Developer Modus schickst - am besten das json welches an zigbee2mqtt geht ?

                          1 Reply Last reply Reply Quote 0
                          • Marc Berg
                            Marc Berg Most Active last edited by Marc Berg

                            @asgothian sagte in NOUS A1Z Steckdose Energiewert auf 0 setzten:

                            Kannst du bitte posten was genau du im Developer Modus schickst - am besten das json welches an zigbee2mqtt geht ?

                            Schau mal, ob das Debug Log hilft, das ich während der Ausführung mitgeschnitten habe:

                            [2024-06-29 08:30:54] debug: 	z2m: Received MQTT message on 'z2m/Powerplug4/1/set' with data '{"command":{"cluster":0,"command":0,"payload":{}}}'
                            [2024-06-29 08:30:54] debug: 	z2m: Publishing 'set' 'command' to 'Powerplug4'
                            [2024-06-29 08:30:54] debug: 	zh:controller:endpoint: ZCL command 0xa4c138949cc39e7e/1 genBasic.resetFactDefault({}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":false,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false})
                            [2024-06-29 08:30:54] debug: 	zh:deconz:driver: DATA_REQUEST - destAddr: 0x18e8 EP:1 SeqNr. 189 request id: 89
                            [2024-06-29 08:30:54] debug: 	zh:deconz:frameparser: DATA_REQUEST RESPONSE - request id: 89 status: 0
                            [2024-06-29 08:30:54] debug: 	zh:deconz:driver: networkstate: 2 apsDataConfirm: 0 apsDataIndication: 0 configChanged: 0 apsRequestFreeSlots: 1
                            [2024-06-29 08:30:54] debug: 	zh:deconz:frameparser: DEVICE_STATE changed: 10100110
                            [2024-06-29 08:30:54] debug: 	zh:deconz:driver: networkstate: 2 apsDataConfirm: 1 apsDataIndication: 0 configChanged: 0 apsRequestFreeSlots: 1
                            [2024-06-29 08:30:54] debug: 	zh:deconz:driver: query aps data confirm
                            [2024-06-29 08:30:54] debug: 	zh:deconz:driver: DATA_CONFIRM - sending data state request - SeqNr. 190
                            [2024-06-29 08:30:54] debug: 	zh:deconz:frameparser: DATA_CONFIRM RESPONSE - destAddr: 0x18e8 request id: 89 confirm status: 0
                            [2024-06-29 08:30:54] debug: 	zh:deconz:driver: networkstate: 2 apsDataConfirm: 0 apsDataIndication: 0 configChanged: 0 apsRequestFreeSlots: 1
                            [2024-06-29 08:30:54] debug: 	zh:deconz: sendZclFrameToEndpoint - message send with transSeq Nr.: 34
                            [2024-06-29 08:30:54] debug: 	zh:deconz: false, false, false, 10000
                            [2024-06-29 08:30:54] debug: 	zh:deconz: resolve request (34)
                            [2024-06-29 08:30:54] debug: 	zh:deconz:frameparser: DEVICE_STATE changed: 10101010
                            [2024-06-29 08:30:54] debug: 	zh:deconz:driver: networkstate: 2 apsDataConfirm: 0 apsDataIndication: 1 configChanged: 0 apsRequestFreeSlots: 1
                            [2024-06-29 08:30:54] debug: 	zh:deconz:frameparser: DEVICE_STATE changed: 10101010
                            [2024-06-29 08:30:54] debug: 	zh:deconz:driver: networkstate: 2 apsDataConfirm: 0 apsDataIndication: 1 configChanged: 0 apsRequestFreeSlots: 1
                            [2024-06-29 08:30:54] debug: 	zh:deconz:driver: query aps data indication
                            [2024-06-29 08:30:54] debug: 	zh:deconz:driver: DATA_INDICATION - sending read data request - SeqNr. 191
                            [2024-06-29 08:30:54] debug: 	zh:deconz:frameparser: DATA_INDICATION RESPONSE - seqNr. 191 srcAddr: 0x18e8 destAddr: 0x0 profile id: 0x104 cluster id: 0x0 lqi: 255
                            [2024-06-29 08:30:54] debug: 	zh:deconz:frameparser: response payload: 24,34,11,0,0
                            [2024-06-29 08:30:54] debug: 	zh:deconz: resolve data request with transSeq Nr.: 34
                            [2024-06-29 08:30:54] debug: 	zh:controller: Received payload: clusterID=0, address=6376, groupID=null, endpoint=1, destinationEndpoint=1, wasBroadcast=false, linkQuality=255, frame={"header":{"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":true,"reservedBits":0},"manufacturerCode":null,"transactionSequenceNumber":34,"commandIdentifier":11},"payload":{"cmdId":0,"statusCode":0},"command":{"ID":11,"name":"defaultRsp","parameters":[{"name":"cmdId","type":32},{"name":"statusCode","type":32}]}}
                            [2024-06-29 08:30:54] debug: 	z2m: MQTT publish: topic 'z2m/Powerplug4/state', payload 'ON'
                            [2024-06-29 08:30:54] debug: 	zh:deconz:driver: networkstate: 2 apsDataConfirm: 0 apsDataIndication: 1 configChanged: 0 apsRequestFreeSlots: 1
                            [2024-06-29 08:30:54] debug: 	zh:deconz: response received (34)
                            [2024-06-29 08:30:54] debug: 	z2m: MQTT publish: topic 'z2m/Powerplug4/power_outage_memory', payload 'restore'
                            [2024-06-29 08:30:54] info: 	zhc:tz: Invoked '0.0' with payload '{}'
                            [2024-06-29 08:30:54] debug: 	z2m: MQTT publish: topic 'z2m/Powerplug4/indicator_mode', payload 'off/on'
                            [2024-06-29 08:30:54] debug: 	z2m: MQTT publish: topic 'z2m/Powerplug4/child_lock', payload 'UNLOCK'
                            [2024-06-29 08:30:54] debug: 	z2m: MQTT publish: topic 'z2m/Powerplug4/voltage', payload '234'
                            [2024-06-29 08:30:54] debug: 	z2m: MQTT publish: topic 'z2m/Powerplug4/last_seen', payload '2024-06-29T08:30:54+02:00'
                            [2024-06-29 08:30:54] debug: 	z2m: MQTT publish: topic 'z2m/Powerplug4/linkquality', payload '255'
                            [2024-06-29 08:30:54] debug: 	z2m: MQTT publish: topic 'z2m/Powerplug4/power', payload '6'
                            [2024-06-29 08:30:54] debug: 	z2m: MQTT publish: topic 'z2m/Powerplug4/current', payload '0.1'
                            [2024-06-29 08:30:54] debug: 	z2m: MQTT publish: topic 'z2m/Powerplug4/energy', payload '0'
                            [2024-06-29 08:30:54] debug: 	z2m: MQTT publish: topic 'z2m/Powerplug4/update-state', payload 'idle'
                            [2024-06-29 08:30:54] debug: 	z2m: MQTT publish: topic 'z2m/Powerplug4/update-installed_version', payload '192'
                            [2024-06-29 08:30:54] debug: 	z2m: MQTT publish: topic 'z2m/Powerplug4/update-latest_version', payload '192'
                            [2024-06-29 08:30:54] debug: 	z2m: MQTT publish: topic 'z2m/Powerplug4/update_available', payload 'false'
                            

                            Erfolgreich ist der Befehl jedenfalls:

                            58f5ef3c-2005-473a-837b-559a6a725e44-grafik.png

                            1 Reply Last reply Reply Quote 0
                            • Marc Berg
                              Marc Berg Most Active @AVO2705 last edited by

                              @avo2705 sagte in NOUS A1Z Steckdose Energiewert auf 0 setzten:

                              schon mal versucht in der Konsole der Tasmota App folgenden Befehl einzugeben:
                              Energytoday 0
                              Energyyesterday 0
                              Energytotal 0

                              In diesem Thread geht's um die Zigbee Variante, kein Tasmota.

                              B 1 Reply Last reply Reply Quote 0
                              • B
                                bastler @Marc Berg last edited by

                                @marc-berg Richtig!

                                Hatte mir ein Nous Gateway gekauft und versucht den Energiewert damit zu löschen, war aber nicht möglich. In der App gibt es keinen entsprechenden Punkt. Jetzt habe ich noch einmal in den Objekten den Energiewert durch Überschreiben auf "0" gesetzt. Klappt aber auch nicht, ist "schreibgeschützt".81150eef-6c71-4c5d-b492-1066778cdc0c-image.jpeg

                                Kann man den Schreibschutz aufheben, wenn ja wie?

                                Homoran 1 Reply Last reply Reply Quote 0
                                • Homoran
                                  Homoran Global Moderator Administrators @bastler last edited by Homoran

                                  @bastler sagte in NOUS A1Z Steckdose Energiewert auf 0 setzten:

                                  Kann man den Schreibschutz aufheben

                                  ja, würde aber wahrscheinlich sofort wieder vom Gerät überschrieben.
                                  Dürfte eine ReadOnly Information sein.

                                  1 Reply Last reply Reply Quote 0
                                  • Asgothian
                                    Asgothian Developer @bastler last edited by

                                    @bastler sagte in NOUS A1Z Steckdose Energiewert auf 0 setzten:

                                    @asgothian Moin, wurde der Bug inzwischen behoben, damit ein Reset der Energiewerte durchgeführt werden kann?

                                    Die Lösung ist:

                                    sendTo('zigbee.0', 'sendToZigbee', {
                                        "id": "zigbee.X.YYYY",
                                        "ep": "1",
                                        "cid": "genBasic",
                                        "cmd": "resetFactDefault",
                                        "cmdType": "functional",
                                        "zclData": {
                                            "null": {}
                                        },
                                        "cfg": null
                                    });
                                    

                                    In Blockly geht das auch:

                                    Screenshot 2024-06-29 at 19.07.00.png

                                    Im Textbaustein muss dann dies stehen:
                                    {"id": "zigbee.X.YYYY","ep": "1","cid": "genBasic","cmd": "resetFactDefault","cmdType": "functional","zclData": {"null": {}},"cfg": null}

                                    In beiden Fällen müssen X und YYYY durch die korrekten Werte ersetzt werden:
                                    X ist die Instanz-ID der Zigbee Instanz ist (0 im Zweifelsfall)
                                    YYYY ist die IEEE des Gerätes, ohne die führende 0x

                                    Ro75 B 3 Replies Last reply Reply Quote 1
                                    • Ro75
                                      Ro75 @Asgothian last edited by

                                      @asgothian Genial. Danke. Sobald der nächste Turnus bei mir ansteht werde ich das in dieser Form umsetzen.

                                      Ro75.

                                      1 Reply Last reply Reply Quote 0
                                      • B
                                        bastler @Asgothian last edited by

                                        @asgothian Danke auch von mir, werde es nach dem Fußball oder morgen versuchen umzusetzen.

                                        1 Reply Last reply Reply Quote 0
                                        • B
                                          bastler @Asgothian last edited by bastler

                                          @asgothian Moin, habe gerade versucht das Blockly umzusetzen:

                                          Bei mir steht noch "parameter1", bei dir nicht? Der Energiewert wurde nicht auf "0" gesetzt.

                                          Habe ich was nicht richtig gemacht?

                                          Danke und Gruß

                                          376130bb-0097-487d-90d6-0ae71d7b8e40-image.jpeg

                                          ea39bf94-434b-487d-add4-0fbc08023594-image.jpeg

                                          Update:

                                          Habe jetzt das Jason Skript probiert, damit funktioniert es. Wo liegt dann der Fehler bei dem Blockly?

                                          Asgothian 1 Reply Last reply Reply Quote 0
                                          • Asgothian
                                            Asgothian Developer @bastler last edited by Asgothian

                                            @bastler sagte in NOUS A1Z Steckdose Energiewert auf 0 setzten:

                                            Habe jetzt das Jason Skript probiert, damit funktioniert es. Wo liegt dann der Fehler bei dem Blockly?

                                            zeig mal das JS was aus dem blockly wird (Screenshot 2024-06-30 at 17.48.59.png ) einmal da clicken. Nichts editieren, dann kannst du nochmal drauf clicken um das Blockly wieder zu bekommen

                                            A.

                                            B 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            688
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            11
                                            47
                                            6218
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo