    Zigbee Adapter nach Stromausfall keine Verbindung (gelöst)

    This topic has been deleted. Only users with topic management privileges can see it.
    • DJMarc75
      DJMarc75 @stefu87_CH last edited by DJMarc75

      @stefu87_ch na dann 🙂

      edit: ist unpreviligiert

      1 Reply Last reply Reply Quote 0
      • crunchip
        crunchip Forum Testing Most Active @stefu87_CH last edited by

        @stefu87_ch was zeigt dann im LXC

        lsusb
        &
        ls -l /dev
        
        S 1 Reply Last reply Reply Quote 0
        • S
          stefu87_CH @crunchip last edited by

          @crunchip sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

          admin@Iobroker:~$ lsusb
          Bus 004 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub
          Bus 003 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub
          Bus 002 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub
          Bus 001 Device 004: ID 8087:0aa7 Intel Corp. Wireless-AC 3168 Bluetooth
          Bus 001 Device 010: ID 1a86:55d4 QinHeng Electronics SONOFF Zigbee 3.0 USB Dongle Plus V2
          Bus 001 Device 008: ID 051d:0002 American Power Conversion Uninterruptible Power Supply
          Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub
          admin@Iobroker:~$ ls -l /dev
          total 0
          crw--w---- 1 root   tty     136, 0 Jul  2 20:13 console
          lrwxrwxrwx 1 root   root        11 Jul  2 20:13 core -> /proc/kcore
          lrwxrwxrwx 1 root   root        13 Jul  2 20:13 fd -> /proc/self/fd
          crw-rw-rw- 1 nobody nogroup   1, 7 Jun 28 19:56 full
          lrwxrwxrwx 1 root   root        12 Jul  2 20:13 initctl -> /run/initctl
          lrwxrwxrwx 1 root   root        28 Jul  2 20:13 log -> /run/systemd/journal/dev-log
          drwxrwxrwt 2 nobody nogroup     40 Jul  2 20:13 mqueue
          crw-rw-rw- 1 nobody nogroup   1, 3 Jun 28 19:56 null
          crw-rw-rw- 1 root   root      5, 2 Jul  3 17:51 ptmx
          drwxr-xr-x 2 root   root         0 Jul  2 20:13 pts
          crw-rw-rw- 1 nobody nogroup   1, 8 Jun 28 19:56 random
          drwxr-xr-x 3 root   root        60 Jul  2 20:13 serial
          drwxrwxrwt 2 root   root        40 Jul  2 20:13 shm
          lrwxrwxrwx 1 root   root        15 Jul  2 20:13 stderr -> /proc/self/fd/2
          lrwxrwxrwx 1 root   root        15 Jul  2 20:13 stdin -> /proc/self/fd/0
          lrwxrwxrwx 1 root   root        15 Jul  2 20:13 stdout -> /proc/self/fd/1
          crw-rw-rw- 1 nobody nogroup   5, 0 Jul  2 20:01 tty
          crw------- 1 admin  tty     136, 1 Jul  3 17:51 tty1
          crw--w---- 1 root   tty     136, 2 Jul  2 20:13 tty2
          crw-rw-rw- 1 nobody nogroup 166, 0 Jul  2 20:21 ttyACM0
          crw-rw-rw- 1 nobody nogroup   1, 9 Jun 28 19:56 urandom
          crw-rw-rw- 1 nobody nogroup   1, 5 Jun 28 19:56 zero
          admin@Iobroker:~$ 
          
          crunchip 1 Reply Last reply Reply Quote 0
          • crunchip
            crunchip Forum Testing Most Active @stefu87_CH last edited by

            @stefu87_ch sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

            ttyACM0

            Wähle das doch mal im Zigbee Adapter aus und guck was passiert

            S 1 Reply Last reply Reply Quote 0
            • S
              stefu87_CH @crunchip last edited by

              @crunchip sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

              @stefu87_ch sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

              ttyACM0

              Wähle das doch mal im Zigbee Adapter aus und guck was passiert

              Fehler im Log:

              024-07-03 18:35:36.622 - error: zigbee.0 (220819) getGroups: caught error: TypeError: Cannot read properties of undefined (reading 'getGroups')
              2024-07-03 18:35:36.715 - info: zigbee.0 (220819) List of port: [{"path":"/dev/ttyACM0"},{"path":"/dev/ttyS0"},{"path":"/dev/ttyS1"},{"path":"/dev/ttyS10"},{"path":"/dev/ttyS11"},{"path":"/dev/ttyS12"},{"path":"/dev/ttyS13"},{"path":"/dev/ttyS14"},{"path":"/dev/ttyS15"},{"path":"/dev/ttyS16"},{"path":"/dev/ttyS17"},{"path":"/dev/ttyS18"},{"path":"/dev/ttyS19"},{"path":"/dev/ttyS2"},{"path":"/dev/ttyS20"},{"path":"/dev/ttyS21"},{"path":"/dev/ttyS22"},{"path":"/dev/ttyS23"},{"path":"/dev/ttyS24"},{"path":"/dev/ttyS25"},{"path":"/dev/ttyS26"},{"path":"/dev/ttyS27"},{"path":"/dev/ttyS28"},{"path":"/dev/ttyS29"},{"path":"/dev/ttyS3"},{"path":"/dev/ttyS30"},{"path":"/dev/ttyS31"},{"path":"/dev/ttyS4"},{"path":"/dev/ttyS5"},{"path":"/dev/ttyS6"},{"path":"/dev/ttyS7"},{"path":"/dev/ttyS8"},{"path":"/dev/ttyS9"}]
              2024-07-03 18:35:48.500 - error: zigbee.0 (220819) Starting zigbee-herdsman problem : "Failed to connect to the adapter (Error: SRSP - SYS - ping after 6000ms)"
              2024-07-03 18:35:48.500 - error: zigbee.0 (220819) Failed to start Zigbee
              2024-07-03 18:35:48.500 - error: zigbee.0 (220819) Error herdsman start
              2024-07-03 18:35:58.502 - info: zigbee.0 (220819) Try to reconnect. 1 attempts left
              2024-07-03 18:35:58.502 - info: zigbee.0 (220819) Starting Zigbee npm ...
              2024-07-03 18:35:58.506 - info: zigbee.0 (220819) Installed Version: iobroker.zigbee@1.10.3
              2024-07-03 18:35:58.596 - error: zigbee.0 (220819) Starting zigbee-herdsman problem : "Error Resource temporarily unavailable Cannot lock port"
              2024-07-03 18:35:58.597 - error: zigbee.0 (220819) Failed to start Zigbee
              2024-07-03 18:35:58.597 - error: zigbee.0 (220819) Error herdsman start
              

              Einstellungen im Adapter:
              669d90d3-2eba-4c7d-aedd-d1e5b94be1c2-grafik.png

              crunchip Thomas Braun 2 Replies Last reply Reply Quote 0
              • crunchip
                crunchip Forum Testing Most Active @stefu87_CH last edited by

                @stefu87_ch sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

                "Failed to connect to the adapter (Error: SRSP - SYS - ping after 6000ms)"

                ist da nicht der falsche Typ angewählt?

                1 Reply Last reply Reply Quote 1
                • Thomas Braun
                  Thomas Braun Most Active @stefu87_CH last edited by

                  @stefu87_ch

                  Der QinHeng Electronics SONOFF Zigbee 3.0 USB Dongle Plus V2
                  läuft mit großer Sicherheit mit dem Silicon Labs EZSP-Stack.

                  S 1 Reply Last reply Reply Quote 0
                  • S
                    stefu87_CH @Thomas Braun last edited by

                    @thomas-braun sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

                    @stefu87_ch

                    Der QinHeng Electronics SONOFF Zigbee 3.0 USB Dongle Plus V2
                    läuft mit großer Sicherheit mit dem Silicon Labs EZSP-Stack.

                    Habe jetzt mal geändert und erhalte nun diese Meldungen:

                    2024-07-04 17:15:48.503 - info: zigbee.0 (443010) starting. Version 1.10.3 in /opt/iobroker/node_modules/iobroker.zigbee, node: v20.15.0, js-controller: 5.0.19
                    2024-07-04 17:15:48.528 - info: zigbee.0 (443010) delete old Backup files. keep only last 10
                    2024-07-04 17:15:48.529 - info: zigbee.0 (443010) Starting Zigbee npm ...
                    2024-07-04 17:15:48.684 - info: zigbee.0 (443010) Installed Version: iobroker.zigbee@1.10.3
                    2024-07-04 17:15:56.205 - info: host.Iobroker stopInstance system.adapter.zigbee.0 (force=false, process=true)
                    2024-07-04 17:15:56.207 - info: zigbee.0 (443010) Got terminate signal TERMINATE_YOURSELF
                    2024-07-04 17:15:56.207 - info: zigbee.0 (443010) cleaned everything up...
                    2024-07-04 17:15:56.208 - info: zigbee.0 (443010) Zigbee: disabling joining new devices.
                    2024-07-04 17:15:56.256 - warn: zigbee.0 (443010) Failed to stop zigbee during startup
                    2024-07-04 17:15:56.256 - info: zigbee.0 (443010) terminating
                    2024-07-04 17:15:56.257 - info: zigbee.0 (443010) Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                    2024-07-04 17:15:56.319 - info: host.Iobroker stopInstance system.adapter.zigbee.0 send kill signal
                    2024-07-04 17:15:56.708 - info: zigbee.0 (443010) terminating
                    2024-07-04 17:15:56.813 - info: host.Iobroker instance system.adapter.zigbee.0 terminated with code 11 (ADAPTER_REQUESTED_TERMINATION)
                    2024-07-04 17:15:59.367 - info: host.Iobroker instance system.adapter.zigbee.0 started with pid 443104
                    2024-07-04 17:16:00.660 - info: zigbee.0 (443104) starting. Version 1.10.3 in /opt/iobroker/node_modules/iobroker.zigbee, node: v20.15.0, js-controller: 5.0.19
                    2024-07-04 17:16:00.683 - info: zigbee.0 (443104) delete old Backup files. keep only last 10
                    2024-07-04 17:16:00.683 - info: zigbee.0 (443104) Starting Zigbee npm ...
                    2024-07-04 17:16:00.827 - info: zigbee.0 (443104) Installed Version: iobroker.zigbee@1.10.3
                    2024-07-04 17:16:00.854 - info: admin.0 (436) <== Disconnect system.user.admin from ::ffff:192.168.0.20
                    2024-07-04 17:16:04.259 - error: zigbee.0 (443104) Starting zigbee-herdsman problem : "startup failed - configuration-adapter mismatch - see logs above for more information"
                    2024-07-04 17:16:04.260 - error: zigbee.0 (443104) Failed to start Zigbee
                    2024-07-04 17:16:04.260 - error: zigbee.0 (443104) Error herdsman start
                    2024-07-04 17:16:14.261 - info: zigbee.0 (443104) Try to reconnect. 1 attempts left
                    2024-07-04 17:16:14.261 - info: zigbee.0 (443104) Starting Zigbee npm ...
                    2024-07-04 17:16:14.265 - info: zigbee.0 (443104) Installed Version: iobroker.zigbee@1.10.3
                    2024-07-04 17:16:44.375 - error: zigbee.0 (443104) Starting zigbee-herdsman problem : "Failure to connect"
                    2024-07-04 17:16:44.376 - error: zigbee.0 (443104) Failed to start Zigbee
                    2024-07-04 17:16:44.376 - error: zigbee.0 (443104) Error herdsman start
                    2024-07-04 17:18:52.678 - info: host.Iobroker stopInstance system.adapter.zigbee.0 (force=false, process=true)
                    2024-07-04 17:18:52.680 - info: zigbee.0 (443104) Got terminate signal TERMINATE_YOURSELF
                    2024-07-04 17:18:52.680 - info: zigbee.0 (443104) cleaned everything up...
                    2024-07-04 17:18:52.681 - info: zigbee.0 (443104) Zigbee: disabling joining new devices.
                    2024-07-04 17:18:52.689 - warn: zigbee.0 (443104) Failed to stop zigbee during startup
                    2024-07-04 17:18:52.689 - info: zigbee.0 (443104) terminating
                    2024-07-04 17:18:52.689 - info: zigbee.0 (443104) Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                    2024-07-04 17:18:52.719 - info: host.Iobroker stopInstance system.adapter.zigbee.0 send kill signal
                    2024-07-04 17:18:53.182 - info: zigbee.0 (443104) terminating
                    2024-07-04 17:18:53.243 - info: host.Iobroker instance system.adapter.zigbee.0 terminated with code 11 (ADAPTER_REQUESTED_TERMINATION)
                    2024-07-04 17:18:55.777 - info: host.Iobroker instance system.adapter.zigbee.0 started with pid 443511
                    2024-07-04 17:18:57.105 - info: zigbee.0 (443511) starting. Version 1.10.3 in /opt/iobroker/node_modules/iobroker.zigbee, node: v20.15.0, js-controller: 5.0.19
                    2024-07-04 17:18:57.129 - info: zigbee.0 (443511) delete old Backup files. keep only last 10
                    2024-07-04 17:18:57.129 - info: zigbee.0 (443511) Starting Zigbee npm ...
                    2024-07-04 17:18:57.269 - info: zigbee.0 (443511) Installed Version: iobroker.zigbee@1.10.3
                    2024-07-04 17:19:00.704 - error: zigbee.0 (443511) Starting zigbee-herdsman problem : "startup failed - configuration-adapter mismatch - see logs above for more information"
                    2024-07-04 17:19:00.704 - error: zigbee.0 (443511) Failed to start Zigbee
                    2024-07-04 17:19:00.705 - error: zigbee.0 (443511) Error herdsman start
                    

                    Ich vermute, die PID stimmt nicht, aber woher weiss ich welche das gebraucht wird?

                    Thomas Braun 1 Reply Last reply Reply Quote 0
                    • Thomas Braun
                      Thomas Braun Most Active @stefu87_CH last edited by

                      @stefu87_ch

                      Früher standen mal beide IDs im Log.
                      Ich weiß nicht warum und wann die rausgeflogen wurden.
                      Du kannst aber hilfsweise mal die 'falschen' Einstellungen in den Einstellungen der Instanz erzwingen.

                      S 1 Reply Last reply Reply Quote 0
                      • S
                        stefu87_CH @Thomas Braun last edited by

                        @thomas-braun sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

                        @stefu87_ch

                        Du kannst aber hilfsweise mal die 'falschen' Einstellungen in den Einstellungen der Instanz erzwingen.

                        Also du meinst eine falsche Pan ID eintragen?
                        3bbe7c99-acd4-477c-ae44-e229290ef370-grafik.png

                        Thomas Braun 1 Reply Last reply Reply Quote 0
                        • Thomas Braun
                          Thomas Braun Most Active @stefu87_CH last edited by

                          @stefu87_ch

                          Ich meinte eher die Einstellung in der letzten Zeile:

                          a4ded092-dd09-4c1a-b513-549b39c58329-grafik.png

                          S 1 Reply Last reply Reply Quote 0
                          • S
                            stefu87_CH @Thomas Braun last edited by

                            @thomas-braun sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

                            @stefu87_ch

                            Ich meinte eher die Einstellung in der letzten Zeile:

                            a4ded092-dd09-4c1a-b513-549b39c58329-grafik.png

                            2024-07-04 18:02:03.015 - info: zigbee.0 (450060) Got terminate signal TERMINATE_YOURSELF
                            2024-07-04 18:02:03.015 - info: zigbee.0 (450060) cleaned everything up...
                            2024-07-04 18:02:03.017 - info: zigbee.0 (450060) Zigbee: disabling joining new devices.
                            2024-07-04 18:02:03.024 - warn: zigbee.0 (450060) Failed to stop zigbee during startup
                            2024-07-04 18:02:03.025 - info: zigbee.0 (450060) terminating
                            2024-07-04 18:02:03.025 - info: zigbee.0 (450060) Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                            2024-07-04 18:02:03.081 - info: host.Iobroker stopInstance system.adapter.zigbee.0 send kill signal
                            2024-07-04 18:02:03.516 - info: zigbee.0 (450060) terminating
                            2024-07-04 18:02:03.577 - info: host.Iobroker instance system.adapter.zigbee.0 terminated with code 11 (ADAPTER_REQUESTED_TERMINATION)
                            2024-07-04 18:02:06.143 - info: host.Iobroker instance system.adapter.zigbee.0 started with pid 450620
                            2024-07-04 18:02:07.742 - info: zigbee.0 (450620) starting. Version 1.10.3 in /opt/iobroker/node_modules/iobroker.zigbee, node: v20.15.0, js-controller: 5.0.19
                            2024-07-04 18:02:07.765 - info: zigbee.0 (450620) delete old Backup files. keep only last 10
                            2024-07-04 18:02:07.766 - info: zigbee.0 (450620) Starting Zigbee npm ...
                            2024-07-04 18:02:07.915 - info: zigbee.0 (450620) Installed Version: iobroker.zigbee@1.10.3
                            2024-07-04 18:02:11.344 - error: zigbee.0 (450620) Starting zigbee-herdsman problem : "startup failed - configuration-adapter mismatch - see logs above for more information"
                            2024-07-04 18:02:11.344 - error: zigbee.0 (450620) Failed to start Zigbee
                            2024-07-04 18:02:11.344 - error: zigbee.0 (450620) Error herdsman start
                            2024-07-04 18:02:21.346 - info: zigbee.0 (450620) Try to reconnect. 1 attempts left
                            2024-07-04 18:02:21.346 - info: zigbee.0 (450620) Starting Zigbee npm ...
                            2024-07-04 18:02:21.352 - info: zigbee.0 (450620) Installed Version: iobroker.zigbee@1.10.3
                            
                            1 Reply Last reply Reply Quote 0
                            • S
                              stefu87_CH last edited by

                              Habe mir jetzt nochmals die Zeit genommen, und wirklich alles neu eingestellt.
                              Jetzt plötzlich hat die Verbindung einwandfrei geklappt.
                              Habe den Adapter mit den Grundeinstellungen belassen und auf einmal ist er grün geworden.

                              1 Reply Last reply Reply Quote 0
                              • First post
                                Last post

                              Support us

                              ioBroker
                              Community Adapters
                              Donate

                              886
                              Online

                              31.9k
                              Users

                              80.2k
                              Topics

                              1.3m
                              Posts

                              9
                              148
                              10826
                              Loading More Posts
                              • Oldest to Newest
                              • Newest to Oldest
                              • Most Votes
                              Reply
                              • Reply as topic
                              Log in to reply
                              Community
                              Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                              The ioBroker Community 2014-2023
                              logo