    Zigbee Adapter nach Stromausfall keine Verbindung (gelöst)

    This topic has been deleted. Only users with topic management privileges can see it.
    • crunchip
      crunchip Forum Testing Most Active @stefu87_CH last edited by

      @stefu87_ch was zeigt dann im LXC

      lsusb
      &
      ls -l /dev
      
      S 1 Reply Last reply Reply Quote 0
      • S
        stefu87_CH @crunchip last edited by

        @crunchip sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

        admin@Iobroker:~$ lsusb
        Bus 004 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub
        Bus 003 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub
        Bus 002 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub
        Bus 001 Device 004: ID 8087:0aa7 Intel Corp. Wireless-AC 3168 Bluetooth
        Bus 001 Device 010: ID 1a86:55d4 QinHeng Electronics SONOFF Zigbee 3.0 USB Dongle Plus V2
        Bus 001 Device 008: ID 051d:0002 American Power Conversion Uninterruptible Power Supply
        Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub
        admin@Iobroker:~$ ls -l /dev
        total 0
        crw--w---- 1 root   tty     136, 0 Jul  2 20:13 console
        lrwxrwxrwx 1 root   root        11 Jul  2 20:13 core -> /proc/kcore
        lrwxrwxrwx 1 root   root        13 Jul  2 20:13 fd -> /proc/self/fd
        crw-rw-rw- 1 nobody nogroup   1, 7 Jun 28 19:56 full
        lrwxrwxrwx 1 root   root        12 Jul  2 20:13 initctl -> /run/initctl
        lrwxrwxrwx 1 root   root        28 Jul  2 20:13 log -> /run/systemd/journal/dev-log
        drwxrwxrwt 2 nobody nogroup     40 Jul  2 20:13 mqueue
        crw-rw-rw- 1 nobody nogroup   1, 3 Jun 28 19:56 null
        crw-rw-rw- 1 root   root      5, 2 Jul  3 17:51 ptmx
        drwxr-xr-x 2 root   root         0 Jul  2 20:13 pts
        crw-rw-rw- 1 nobody nogroup   1, 8 Jun 28 19:56 random
        drwxr-xr-x 3 root   root        60 Jul  2 20:13 serial
        drwxrwxrwt 2 root   root        40 Jul  2 20:13 shm
        lrwxrwxrwx 1 root   root        15 Jul  2 20:13 stderr -> /proc/self/fd/2
        lrwxrwxrwx 1 root   root        15 Jul  2 20:13 stdin -> /proc/self/fd/0
        lrwxrwxrwx 1 root   root        15 Jul  2 20:13 stdout -> /proc/self/fd/1
        crw-rw-rw- 1 nobody nogroup   5, 0 Jul  2 20:01 tty
        crw------- 1 admin  tty     136, 1 Jul  3 17:51 tty1
        crw--w---- 1 root   tty     136, 2 Jul  2 20:13 tty2
        crw-rw-rw- 1 nobody nogroup 166, 0 Jul  2 20:21 ttyACM0
        crw-rw-rw- 1 nobody nogroup   1, 9 Jun 28 19:56 urandom
        crw-rw-rw- 1 nobody nogroup   1, 5 Jun 28 19:56 zero
        admin@Iobroker:~$ 
        
        crunchip 1 Reply Last reply Reply Quote 0
        • crunchip
          crunchip Forum Testing Most Active @stefu87_CH last edited by

          @stefu87_ch sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

          ttyACM0

          Wähle das doch mal im Zigbee Adapter aus und guck was passiert

          S 1 Reply Last reply Reply Quote 0
          • S
            stefu87_CH @crunchip last edited by

            @crunchip sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

            @stefu87_ch sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

            ttyACM0

            Wähle das doch mal im Zigbee Adapter aus und guck was passiert

            Fehler im Log:

            024-07-03 18:35:36.622 - error: zigbee.0 (220819) getGroups: caught error: TypeError: Cannot read properties of undefined (reading 'getGroups')
            2024-07-03 18:35:36.715 - info: zigbee.0 (220819) List of port: [{"path":"/dev/ttyACM0"},{"path":"/dev/ttyS0"},{"path":"/dev/ttyS1"},{"path":"/dev/ttyS10"},{"path":"/dev/ttyS11"},{"path":"/dev/ttyS12"},{"path":"/dev/ttyS13"},{"path":"/dev/ttyS14"},{"path":"/dev/ttyS15"},{"path":"/dev/ttyS16"},{"path":"/dev/ttyS17"},{"path":"/dev/ttyS18"},{"path":"/dev/ttyS19"},{"path":"/dev/ttyS2"},{"path":"/dev/ttyS20"},{"path":"/dev/ttyS21"},{"path":"/dev/ttyS22"},{"path":"/dev/ttyS23"},{"path":"/dev/ttyS24"},{"path":"/dev/ttyS25"},{"path":"/dev/ttyS26"},{"path":"/dev/ttyS27"},{"path":"/dev/ttyS28"},{"path":"/dev/ttyS29"},{"path":"/dev/ttyS3"},{"path":"/dev/ttyS30"},{"path":"/dev/ttyS31"},{"path":"/dev/ttyS4"},{"path":"/dev/ttyS5"},{"path":"/dev/ttyS6"},{"path":"/dev/ttyS7"},{"path":"/dev/ttyS8"},{"path":"/dev/ttyS9"}]
            2024-07-03 18:35:48.500 - error: zigbee.0 (220819) Starting zigbee-herdsman problem : "Failed to connect to the adapter (Error: SRSP - SYS - ping after 6000ms)"
            2024-07-03 18:35:48.500 - error: zigbee.0 (220819) Failed to start Zigbee
            2024-07-03 18:35:48.500 - error: zigbee.0 (220819) Error herdsman start
            2024-07-03 18:35:58.502 - info: zigbee.0 (220819) Try to reconnect. 1 attempts left
            2024-07-03 18:35:58.502 - info: zigbee.0 (220819) Starting Zigbee npm ...
            2024-07-03 18:35:58.506 - info: zigbee.0 (220819) Installed Version: iobroker.zigbee@1.10.3
            2024-07-03 18:35:58.596 - error: zigbee.0 (220819) Starting zigbee-herdsman problem : "Error Resource temporarily unavailable Cannot lock port"
            2024-07-03 18:35:58.597 - error: zigbee.0 (220819) Failed to start Zigbee
            2024-07-03 18:35:58.597 - error: zigbee.0 (220819) Error herdsman start
            

            Einstellungen im Adapter:
            669d90d3-2eba-4c7d-aedd-d1e5b94be1c2-grafik.png

            crunchip Thomas Braun 2 Replies Last reply Reply Quote 0
            • crunchip
              crunchip Forum Testing Most Active @stefu87_CH last edited by

              @stefu87_ch sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

              "Failed to connect to the adapter (Error: SRSP - SYS - ping after 6000ms)"

              ist da nicht der falsche Typ angewählt?

              1 Reply Last reply Reply Quote 1
              • Thomas Braun
                Thomas Braun Most Active @stefu87_CH last edited by

                @stefu87_ch

                Der QinHeng Electronics SONOFF Zigbee 3.0 USB Dongle Plus V2
                läuft mit großer Sicherheit mit dem Silicon Labs EZSP-Stack.

                S 1 Reply Last reply Reply Quote 0
                • S
                  stefu87_CH @Thomas Braun last edited by

                  @thomas-braun sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

                  @stefu87_ch

                  Der QinHeng Electronics SONOFF Zigbee 3.0 USB Dongle Plus V2
                  läuft mit großer Sicherheit mit dem Silicon Labs EZSP-Stack.

                  Habe jetzt mal geändert und erhalte nun diese Meldungen:

                  2024-07-04 17:15:48.503 - info: zigbee.0 (443010) starting. Version 1.10.3 in /opt/iobroker/node_modules/iobroker.zigbee, node: v20.15.0, js-controller: 5.0.19
                  2024-07-04 17:15:48.528 - info: zigbee.0 (443010) delete old Backup files. keep only last 10
                  2024-07-04 17:15:48.529 - info: zigbee.0 (443010) Starting Zigbee npm ...
                  2024-07-04 17:15:48.684 - info: zigbee.0 (443010) Installed Version: iobroker.zigbee@1.10.3
                  2024-07-04 17:15:56.205 - info: host.Iobroker stopInstance system.adapter.zigbee.0 (force=false, process=true)
                  2024-07-04 17:15:56.207 - info: zigbee.0 (443010) Got terminate signal TERMINATE_YOURSELF
                  2024-07-04 17:15:56.207 - info: zigbee.0 (443010) cleaned everything up...
                  2024-07-04 17:15:56.208 - info: zigbee.0 (443010) Zigbee: disabling joining new devices.
                  2024-07-04 17:15:56.256 - warn: zigbee.0 (443010) Failed to stop zigbee during startup
                  2024-07-04 17:15:56.256 - info: zigbee.0 (443010) terminating
                  2024-07-04 17:15:56.257 - info: zigbee.0 (443010) Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                  2024-07-04 17:15:56.319 - info: host.Iobroker stopInstance system.adapter.zigbee.0 send kill signal
                  2024-07-04 17:15:56.708 - info: zigbee.0 (443010) terminating
                  2024-07-04 17:15:56.813 - info: host.Iobroker instance system.adapter.zigbee.0 terminated with code 11 (ADAPTER_REQUESTED_TERMINATION)
                  2024-07-04 17:15:59.367 - info: host.Iobroker instance system.adapter.zigbee.0 started with pid 443104
                  2024-07-04 17:16:00.660 - info: zigbee.0 (443104) starting. Version 1.10.3 in /opt/iobroker/node_modules/iobroker.zigbee, node: v20.15.0, js-controller: 5.0.19
                  2024-07-04 17:16:00.683 - info: zigbee.0 (443104) delete old Backup files. keep only last 10
                  2024-07-04 17:16:00.683 - info: zigbee.0 (443104) Starting Zigbee npm ...
                  2024-07-04 17:16:00.827 - info: zigbee.0 (443104) Installed Version: iobroker.zigbee@1.10.3
                  2024-07-04 17:16:00.854 - info: admin.0 (436) <== Disconnect system.user.admin from ::ffff:192.168.0.20
                  2024-07-04 17:16:04.259 - error: zigbee.0 (443104) Starting zigbee-herdsman problem : "startup failed - configuration-adapter mismatch - see logs above for more information"
                  2024-07-04 17:16:04.260 - error: zigbee.0 (443104) Failed to start Zigbee
                  2024-07-04 17:16:04.260 - error: zigbee.0 (443104) Error herdsman start
                  2024-07-04 17:16:14.261 - info: zigbee.0 (443104) Try to reconnect. 1 attempts left
                  2024-07-04 17:16:14.261 - info: zigbee.0 (443104) Starting Zigbee npm ...
                  2024-07-04 17:16:14.265 - info: zigbee.0 (443104) Installed Version: iobroker.zigbee@1.10.3
                  2024-07-04 17:16:44.375 - error: zigbee.0 (443104) Starting zigbee-herdsman problem : "Failure to connect"
                  2024-07-04 17:16:44.376 - error: zigbee.0 (443104) Failed to start Zigbee
                  2024-07-04 17:16:44.376 - error: zigbee.0 (443104) Error herdsman start
                  2024-07-04 17:18:52.678 - info: host.Iobroker stopInstance system.adapter.zigbee.0 (force=false, process=true)
                  2024-07-04 17:18:52.680 - info: zigbee.0 (443104) Got terminate signal TERMINATE_YOURSELF
                  2024-07-04 17:18:52.680 - info: zigbee.0 (443104) cleaned everything up...
                  2024-07-04 17:18:52.681 - info: zigbee.0 (443104) Zigbee: disabling joining new devices.
                  2024-07-04 17:18:52.689 - warn: zigbee.0 (443104) Failed to stop zigbee during startup
                  2024-07-04 17:18:52.689 - info: zigbee.0 (443104) terminating
                  2024-07-04 17:18:52.689 - info: zigbee.0 (443104) Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                  2024-07-04 17:18:52.719 - info: host.Iobroker stopInstance system.adapter.zigbee.0 send kill signal
                  2024-07-04 17:18:53.182 - info: zigbee.0 (443104) terminating
                  2024-07-04 17:18:53.243 - info: host.Iobroker instance system.adapter.zigbee.0 terminated with code 11 (ADAPTER_REQUESTED_TERMINATION)
                  2024-07-04 17:18:55.777 - info: host.Iobroker instance system.adapter.zigbee.0 started with pid 443511
                  2024-07-04 17:18:57.105 - info: zigbee.0 (443511) starting. Version 1.10.3 in /opt/iobroker/node_modules/iobroker.zigbee, node: v20.15.0, js-controller: 5.0.19
                  2024-07-04 17:18:57.129 - info: zigbee.0 (443511) delete old Backup files. keep only last 10
                  2024-07-04 17:18:57.129 - info: zigbee.0 (443511) Starting Zigbee npm ...
                  2024-07-04 17:18:57.269 - info: zigbee.0 (443511) Installed Version: iobroker.zigbee@1.10.3
                  2024-07-04 17:19:00.704 - error: zigbee.0 (443511) Starting zigbee-herdsman problem : "startup failed - configuration-adapter mismatch - see logs above for more information"
                  2024-07-04 17:19:00.704 - error: zigbee.0 (443511) Failed to start Zigbee
                  2024-07-04 17:19:00.705 - error: zigbee.0 (443511) Error herdsman start
                  

                  Ich vermute, die PID stimmt nicht, aber woher weiss ich welche das gebraucht wird?

                  Thomas Braun 1 Reply Last reply Reply Quote 0
                  • Thomas Braun
                    Thomas Braun Most Active @stefu87_CH last edited by

                    @stefu87_ch

                    Früher standen mal beide IDs im Log.
                    Ich weiß nicht warum und wann die rausgeflogen wurden.
                    Du kannst aber hilfsweise mal die 'falschen' Einstellungen in den Einstellungen der Instanz erzwingen.

                    S 1 Reply Last reply Reply Quote 0
                    • S
                      stefu87_CH @Thomas Braun last edited by

                      @thomas-braun sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

                      @stefu87_ch

                      Du kannst aber hilfsweise mal die 'falschen' Einstellungen in den Einstellungen der Instanz erzwingen.

                      Also du meinst eine falsche Pan ID eintragen?
                      3bbe7c99-acd4-477c-ae44-e229290ef370-grafik.png

                      Thomas Braun 1 Reply Last reply Reply Quote 0
                      • Thomas Braun
                        Thomas Braun Most Active @stefu87_CH last edited by

                        @stefu87_ch

                        Ich meinte eher die Einstellung in der letzten Zeile:

                        a4ded092-dd09-4c1a-b513-549b39c58329-grafik.png

                        S 1 Reply Last reply Reply Quote 0
                        • S
                          stefu87_CH @Thomas Braun last edited by

                          @thomas-braun sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

                          @stefu87_ch

                          Ich meinte eher die Einstellung in der letzten Zeile:

                          a4ded092-dd09-4c1a-b513-549b39c58329-grafik.png

                          2024-07-04 18:02:03.015 - info: zigbee.0 (450060) Got terminate signal TERMINATE_YOURSELF
                          2024-07-04 18:02:03.015 - info: zigbee.0 (450060) cleaned everything up...
                          2024-07-04 18:02:03.017 - info: zigbee.0 (450060) Zigbee: disabling joining new devices.
                          2024-07-04 18:02:03.024 - warn: zigbee.0 (450060) Failed to stop zigbee during startup
                          2024-07-04 18:02:03.025 - info: zigbee.0 (450060) terminating
                          2024-07-04 18:02:03.025 - info: zigbee.0 (450060) Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                          2024-07-04 18:02:03.081 - info: host.Iobroker stopInstance system.adapter.zigbee.0 send kill signal
                          2024-07-04 18:02:03.516 - info: zigbee.0 (450060) terminating
                          2024-07-04 18:02:03.577 - info: host.Iobroker instance system.adapter.zigbee.0 terminated with code 11 (ADAPTER_REQUESTED_TERMINATION)
                          2024-07-04 18:02:06.143 - info: host.Iobroker instance system.adapter.zigbee.0 started with pid 450620
                          2024-07-04 18:02:07.742 - info: zigbee.0 (450620) starting. Version 1.10.3 in /opt/iobroker/node_modules/iobroker.zigbee, node: v20.15.0, js-controller: 5.0.19
                          2024-07-04 18:02:07.765 - info: zigbee.0 (450620) delete old Backup files. keep only last 10
                          2024-07-04 18:02:07.766 - info: zigbee.0 (450620) Starting Zigbee npm ...
                          2024-07-04 18:02:07.915 - info: zigbee.0 (450620) Installed Version: iobroker.zigbee@1.10.3
                          2024-07-04 18:02:11.344 - error: zigbee.0 (450620) Starting zigbee-herdsman problem : "startup failed - configuration-adapter mismatch - see logs above for more information"
                          2024-07-04 18:02:11.344 - error: zigbee.0 (450620) Failed to start Zigbee
                          2024-07-04 18:02:11.344 - error: zigbee.0 (450620) Error herdsman start
                          2024-07-04 18:02:21.346 - info: zigbee.0 (450620) Try to reconnect. 1 attempts left
                          2024-07-04 18:02:21.346 - info: zigbee.0 (450620) Starting Zigbee npm ...
                          2024-07-04 18:02:21.352 - info: zigbee.0 (450620) Installed Version: iobroker.zigbee@1.10.3
                          
                          1 Reply Last reply Reply Quote 0
                          • S
                            stefu87_CH last edited by

                            Habe mir jetzt nochmals die Zeit genommen, und wirklich alles neu eingestellt.
                            Jetzt plötzlich hat die Verbindung einwandfrei geklappt.
                            Habe den Adapter mit den Grundeinstellungen belassen und auf einmal ist er grün geworden.

                            1 Reply Last reply Reply Quote 0
                            • First post
                              Last post

                            Support us

                            ioBroker
                            Community Adapters
                            Donate

                            893
                            Online

                            31.9k
                            Users

                            80.2k
                            Topics

                            1.3m
                            Posts

                            9
                            148
                            10826
                            Loading More Posts
                            • Oldest to Newest
                            • Newest to Oldest
                            • Most Votes
                            Reply
                            • Reply as topic
                            Log in to reply
                            Community
                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                            The ioBroker Community 2014-2023
                            logo