    Zigbee Adapter nach Stromausfall keine Verbindung (gelöst)

    This topic has been deleted. Only users with topic management privileges can see it.
    • S
      stefu87_CH @crunchip last edited by

      @crunchip sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

      admin@Iobroker:~$ lsusb
      Bus 004 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub
      Bus 003 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub
      Bus 002 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub
      Bus 001 Device 004: ID 8087:0aa7 Intel Corp. Wireless-AC 3168 Bluetooth
      Bus 001 Device 010: ID 1a86:55d4 QinHeng Electronics SONOFF Zigbee 3.0 USB Dongle Plus V2
      Bus 001 Device 008: ID 051d:0002 American Power Conversion Uninterruptible Power Supply
      Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub
      admin@Iobroker:~$ ls -l /dev
      total 0
      crw--w---- 1 root   tty     136, 0 Jul  2 20:13 console
      lrwxrwxrwx 1 root   root        11 Jul  2 20:13 core -> /proc/kcore
      lrwxrwxrwx 1 root   root        13 Jul  2 20:13 fd -> /proc/self/fd
      crw-rw-rw- 1 nobody nogroup   1, 7 Jun 28 19:56 full
      lrwxrwxrwx 1 root   root        12 Jul  2 20:13 initctl -> /run/initctl
      lrwxrwxrwx 1 root   root        28 Jul  2 20:13 log -> /run/systemd/journal/dev-log
      drwxrwxrwt 2 nobody nogroup     40 Jul  2 20:13 mqueue
      crw-rw-rw- 1 nobody nogroup   1, 3 Jun 28 19:56 null
      crw-rw-rw- 1 root   root      5, 2 Jul  3 17:51 ptmx
      drwxr-xr-x 2 root   root         0 Jul  2 20:13 pts
      crw-rw-rw- 1 nobody nogroup   1, 8 Jun 28 19:56 random
      drwxr-xr-x 3 root   root        60 Jul  2 20:13 serial
      drwxrwxrwt 2 root   root        40 Jul  2 20:13 shm
      lrwxrwxrwx 1 root   root        15 Jul  2 20:13 stderr -> /proc/self/fd/2
      lrwxrwxrwx 1 root   root        15 Jul  2 20:13 stdin -> /proc/self/fd/0
      lrwxrwxrwx 1 root   root        15 Jul  2 20:13 stdout -> /proc/self/fd/1
      crw-rw-rw- 1 nobody nogroup   5, 0 Jul  2 20:01 tty
      crw------- 1 admin  tty     136, 1 Jul  3 17:51 tty1
      crw--w---- 1 root   tty     136, 2 Jul  2 20:13 tty2
      crw-rw-rw- 1 nobody nogroup 166, 0 Jul  2 20:21 ttyACM0
      crw-rw-rw- 1 nobody nogroup   1, 9 Jun 28 19:56 urandom
      crw-rw-rw- 1 nobody nogroup   1, 5 Jun 28 19:56 zero
      admin@Iobroker:~$ 
      
      crunchip 1 Reply Last reply Reply Quote 0
      • crunchip
        crunchip Forum Testing Most Active @stefu87_CH last edited by

        @stefu87_ch sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

        ttyACM0

        Wähle das doch mal im Zigbee Adapter aus und guck was passiert

        S 1 Reply Last reply Reply Quote 0
        • S
          stefu87_CH @crunchip last edited by

          @crunchip sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

          @stefu87_ch sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

          ttyACM0

          Wähle das doch mal im Zigbee Adapter aus und guck was passiert

          Fehler im Log:

          024-07-03 18:35:36.622 - error: zigbee.0 (220819) getGroups: caught error: TypeError: Cannot read properties of undefined (reading 'getGroups')
          2024-07-03 18:35:36.715 - info: zigbee.0 (220819) List of port: [{"path":"/dev/ttyACM0"},{"path":"/dev/ttyS0"},{"path":"/dev/ttyS1"},{"path":"/dev/ttyS10"},{"path":"/dev/ttyS11"},{"path":"/dev/ttyS12"},{"path":"/dev/ttyS13"},{"path":"/dev/ttyS14"},{"path":"/dev/ttyS15"},{"path":"/dev/ttyS16"},{"path":"/dev/ttyS17"},{"path":"/dev/ttyS18"},{"path":"/dev/ttyS19"},{"path":"/dev/ttyS2"},{"path":"/dev/ttyS20"},{"path":"/dev/ttyS21"},{"path":"/dev/ttyS22"},{"path":"/dev/ttyS23"},{"path":"/dev/ttyS24"},{"path":"/dev/ttyS25"},{"path":"/dev/ttyS26"},{"path":"/dev/ttyS27"},{"path":"/dev/ttyS28"},{"path":"/dev/ttyS29"},{"path":"/dev/ttyS3"},{"path":"/dev/ttyS30"},{"path":"/dev/ttyS31"},{"path":"/dev/ttyS4"},{"path":"/dev/ttyS5"},{"path":"/dev/ttyS6"},{"path":"/dev/ttyS7"},{"path":"/dev/ttyS8"},{"path":"/dev/ttyS9"}]
          2024-07-03 18:35:48.500 - error: zigbee.0 (220819) Starting zigbee-herdsman problem : "Failed to connect to the adapter (Error: SRSP - SYS - ping after 6000ms)"
          2024-07-03 18:35:48.500 - error: zigbee.0 (220819) Failed to start Zigbee
          2024-07-03 18:35:48.500 - error: zigbee.0 (220819) Error herdsman start
          2024-07-03 18:35:58.502 - info: zigbee.0 (220819) Try to reconnect. 1 attempts left
          2024-07-03 18:35:58.502 - info: zigbee.0 (220819) Starting Zigbee npm ...
          2024-07-03 18:35:58.506 - info: zigbee.0 (220819) Installed Version: iobroker.zigbee@1.10.3
          2024-07-03 18:35:58.596 - error: zigbee.0 (220819) Starting zigbee-herdsman problem : "Error Resource temporarily unavailable Cannot lock port"
          2024-07-03 18:35:58.597 - error: zigbee.0 (220819) Failed to start Zigbee
          2024-07-03 18:35:58.597 - error: zigbee.0 (220819) Error herdsman start
          

          Einstellungen im Adapter:
          669d90d3-2eba-4c7d-aedd-d1e5b94be1c2-grafik.png

          crunchip Thomas Braun 2 Replies Last reply Reply Quote 0
          • crunchip
            crunchip Forum Testing Most Active @stefu87_CH last edited by

            @stefu87_ch sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

            "Failed to connect to the adapter (Error: SRSP - SYS - ping after 6000ms)"

            ist da nicht der falsche Typ angewählt?

            1 Reply Last reply Reply Quote 1
            • Thomas Braun
              Thomas Braun Most Active @stefu87_CH last edited by

              @stefu87_ch

              Der QinHeng Electronics SONOFF Zigbee 3.0 USB Dongle Plus V2
              läuft mit großer Sicherheit mit dem Silicon Labs EZSP-Stack.

              S 1 Reply Last reply Reply Quote 0
              • S
                stefu87_CH @Thomas Braun last edited by

                @thomas-braun sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

                @stefu87_ch

                Der QinHeng Electronics SONOFF Zigbee 3.0 USB Dongle Plus V2
                läuft mit großer Sicherheit mit dem Silicon Labs EZSP-Stack.

                Habe jetzt mal geändert und erhalte nun diese Meldungen:

                2024-07-04 17:15:48.503 - info: zigbee.0 (443010) starting. Version 1.10.3 in /opt/iobroker/node_modules/iobroker.zigbee, node: v20.15.0, js-controller: 5.0.19
                2024-07-04 17:15:48.528 - info: zigbee.0 (443010) delete old Backup files. keep only last 10
                2024-07-04 17:15:48.529 - info: zigbee.0 (443010) Starting Zigbee npm ...
                2024-07-04 17:15:48.684 - info: zigbee.0 (443010) Installed Version: iobroker.zigbee@1.10.3
                2024-07-04 17:15:56.205 - info: host.Iobroker stopInstance system.adapter.zigbee.0 (force=false, process=true)
                2024-07-04 17:15:56.207 - info: zigbee.0 (443010) Got terminate signal TERMINATE_YOURSELF
                2024-07-04 17:15:56.207 - info: zigbee.0 (443010) cleaned everything up...
                2024-07-04 17:15:56.208 - info: zigbee.0 (443010) Zigbee: disabling joining new devices.
                2024-07-04 17:15:56.256 - warn: zigbee.0 (443010) Failed to stop zigbee during startup
                2024-07-04 17:15:56.256 - info: zigbee.0 (443010) terminating
                2024-07-04 17:15:56.257 - info: zigbee.0 (443010) Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                2024-07-04 17:15:56.319 - info: host.Iobroker stopInstance system.adapter.zigbee.0 send kill signal
                2024-07-04 17:15:56.708 - info: zigbee.0 (443010) terminating
                2024-07-04 17:15:56.813 - info: host.Iobroker instance system.adapter.zigbee.0 terminated with code 11 (ADAPTER_REQUESTED_TERMINATION)
                2024-07-04 17:15:59.367 - info: host.Iobroker instance system.adapter.zigbee.0 started with pid 443104
                2024-07-04 17:16:00.660 - info: zigbee.0 (443104) starting. Version 1.10.3 in /opt/iobroker/node_modules/iobroker.zigbee, node: v20.15.0, js-controller: 5.0.19
                2024-07-04 17:16:00.683 - info: zigbee.0 (443104) delete old Backup files. keep only last 10
                2024-07-04 17:16:00.683 - info: zigbee.0 (443104) Starting Zigbee npm ...
                2024-07-04 17:16:00.827 - info: zigbee.0 (443104) Installed Version: iobroker.zigbee@1.10.3
                2024-07-04 17:16:00.854 - info: admin.0 (436) <== Disconnect system.user.admin from ::ffff:192.168.0.20
                2024-07-04 17:16:04.259 - error: zigbee.0 (443104) Starting zigbee-herdsman problem : "startup failed - configuration-adapter mismatch - see logs above for more information"
                2024-07-04 17:16:04.260 - error: zigbee.0 (443104) Failed to start Zigbee
                2024-07-04 17:16:04.260 - error: zigbee.0 (443104) Error herdsman start
                2024-07-04 17:16:14.261 - info: zigbee.0 (443104) Try to reconnect. 1 attempts left
                2024-07-04 17:16:14.261 - info: zigbee.0 (443104) Starting Zigbee npm ...
                2024-07-04 17:16:14.265 - info: zigbee.0 (443104) Installed Version: iobroker.zigbee@1.10.3
                2024-07-04 17:16:44.375 - error: zigbee.0 (443104) Starting zigbee-herdsman problem : "Failure to connect"
                2024-07-04 17:16:44.376 - error: zigbee.0 (443104) Failed to start Zigbee
                2024-07-04 17:16:44.376 - error: zigbee.0 (443104) Error herdsman start
                2024-07-04 17:18:52.678 - info: host.Iobroker stopInstance system.adapter.zigbee.0 (force=false, process=true)
                2024-07-04 17:18:52.680 - info: zigbee.0 (443104) Got terminate signal TERMINATE_YOURSELF
                2024-07-04 17:18:52.680 - info: zigbee.0 (443104) cleaned everything up...
                2024-07-04 17:18:52.681 - info: zigbee.0 (443104) Zigbee: disabling joining new devices.
                2024-07-04 17:18:52.689 - warn: zigbee.0 (443104) Failed to stop zigbee during startup
                2024-07-04 17:18:52.689 - info: zigbee.0 (443104) terminating
                2024-07-04 17:18:52.689 - info: zigbee.0 (443104) Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                2024-07-04 17:18:52.719 - info: host.Iobroker stopInstance system.adapter.zigbee.0 send kill signal
                2024-07-04 17:18:53.182 - info: zigbee.0 (443104) terminating
                2024-07-04 17:18:53.243 - info: host.Iobroker instance system.adapter.zigbee.0 terminated with code 11 (ADAPTER_REQUESTED_TERMINATION)
                2024-07-04 17:18:55.777 - info: host.Iobroker instance system.adapter.zigbee.0 started with pid 443511
                2024-07-04 17:18:57.105 - info: zigbee.0 (443511) starting. Version 1.10.3 in /opt/iobroker/node_modules/iobroker.zigbee, node: v20.15.0, js-controller: 5.0.19
                2024-07-04 17:18:57.129 - info: zigbee.0 (443511) delete old Backup files. keep only last 10
                2024-07-04 17:18:57.129 - info: zigbee.0 (443511) Starting Zigbee npm ...
                2024-07-04 17:18:57.269 - info: zigbee.0 (443511) Installed Version: iobroker.zigbee@1.10.3
                2024-07-04 17:19:00.704 - error: zigbee.0 (443511) Starting zigbee-herdsman problem : "startup failed - configuration-adapter mismatch - see logs above for more information"
                2024-07-04 17:19:00.704 - error: zigbee.0 (443511) Failed to start Zigbee
                2024-07-04 17:19:00.705 - error: zigbee.0 (443511) Error herdsman start
                

                Ich vermute, die PID stimmt nicht, aber woher weiss ich welche das gebraucht wird?

                Thomas Braun 1 Reply Last reply Reply Quote 0
                • Thomas Braun
                  Thomas Braun Most Active @stefu87_CH last edited by

                  @stefu87_ch

                  Früher standen mal beide IDs im Log.
                  Ich weiß nicht warum und wann die rausgeflogen wurden.
                  Du kannst aber hilfsweise mal die 'falschen' Einstellungen in den Einstellungen der Instanz erzwingen.

                  S 1 Reply Last reply Reply Quote 0
                  • S
                    stefu87_CH @Thomas Braun last edited by

                    @thomas-braun sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

                    @stefu87_ch

                    Du kannst aber hilfsweise mal die 'falschen' Einstellungen in den Einstellungen der Instanz erzwingen.

                    Also du meinst eine falsche Pan ID eintragen?
                    3bbe7c99-acd4-477c-ae44-e229290ef370-grafik.png

                    Thomas Braun 1 Reply Last reply Reply Quote 0
                    • Thomas Braun
                      Thomas Braun Most Active @stefu87_CH last edited by

                      @stefu87_ch

                      Ich meinte eher die Einstellung in der letzten Zeile:

                      a4ded092-dd09-4c1a-b513-549b39c58329-grafik.png

                      S 1 Reply Last reply Reply Quote 0
                      • S
                        stefu87_CH @Thomas Braun last edited by

                        @thomas-braun sagte in Zigbee Adapter nach Stromausfall keine Verbindung:

                        @stefu87_ch

                        Ich meinte eher die Einstellung in der letzten Zeile:

                        a4ded092-dd09-4c1a-b513-549b39c58329-grafik.png

                        2024-07-04 18:02:03.015 - info: zigbee.0 (450060) Got terminate signal TERMINATE_YOURSELF
                        2024-07-04 18:02:03.015 - info: zigbee.0 (450060) cleaned everything up...
                        2024-07-04 18:02:03.017 - info: zigbee.0 (450060) Zigbee: disabling joining new devices.
                        2024-07-04 18:02:03.024 - warn: zigbee.0 (450060) Failed to stop zigbee during startup
                        2024-07-04 18:02:03.025 - info: zigbee.0 (450060) terminating
                        2024-07-04 18:02:03.025 - info: zigbee.0 (450060) Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                        2024-07-04 18:02:03.081 - info: host.Iobroker stopInstance system.adapter.zigbee.0 send kill signal
                        2024-07-04 18:02:03.516 - info: zigbee.0 (450060) terminating
                        2024-07-04 18:02:03.577 - info: host.Iobroker instance system.adapter.zigbee.0 terminated with code 11 (ADAPTER_REQUESTED_TERMINATION)
                        2024-07-04 18:02:06.143 - info: host.Iobroker instance system.adapter.zigbee.0 started with pid 450620
                        2024-07-04 18:02:07.742 - info: zigbee.0 (450620) starting. Version 1.10.3 in /opt/iobroker/node_modules/iobroker.zigbee, node: v20.15.0, js-controller: 5.0.19
                        2024-07-04 18:02:07.765 - info: zigbee.0 (450620) delete old Backup files. keep only last 10
                        2024-07-04 18:02:07.766 - info: zigbee.0 (450620) Starting Zigbee npm ...
                        2024-07-04 18:02:07.915 - info: zigbee.0 (450620) Installed Version: iobroker.zigbee@1.10.3
                        2024-07-04 18:02:11.344 - error: zigbee.0 (450620) Starting zigbee-herdsman problem : "startup failed - configuration-adapter mismatch - see logs above for more information"
                        2024-07-04 18:02:11.344 - error: zigbee.0 (450620) Failed to start Zigbee
                        2024-07-04 18:02:11.344 - error: zigbee.0 (450620) Error herdsman start
                        2024-07-04 18:02:21.346 - info: zigbee.0 (450620) Try to reconnect. 1 attempts left
                        2024-07-04 18:02:21.346 - info: zigbee.0 (450620) Starting Zigbee npm ...
                        2024-07-04 18:02:21.352 - info: zigbee.0 (450620) Installed Version: iobroker.zigbee@1.10.3
                        
                        1 Reply Last reply Reply Quote 0
                        • S
                          stefu87_CH last edited by

                          Habe mir jetzt nochmals die Zeit genommen, und wirklich alles neu eingestellt.
                          Jetzt plötzlich hat die Verbindung einwandfrei geklappt.
                          Habe den Adapter mit den Grundeinstellungen belassen und auf einmal ist er grün geworden.

                          1 Reply Last reply Reply Quote 0
                          • First post
                            Last post

                          Support us

                          ioBroker
                          Community Adapters
                          Donate

                          887
                          Online

                          31.9k
                          Users

                          80.2k
                          Topics

                          1.3m
                          Posts

                          9
                          148
                          10826
                          Loading More Posts
                          • Oldest to Newest
                          • Newest to Oldest
                          • Most Votes
                          Reply
                          • Reply as topic
                          Log in to reply
                          Community
                          Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                          The ioBroker Community 2014-2023
                          logo