      manrum1 @metaxa last edited by

      @metaxa Sorry, dass ich jetzt erst antworte. Probier "admin" bei user und Passwort.

      1 Reply Last reply Reply Quote 0
      • T
        TinoNikol @manrum1 last edited by TinoNikol

        @metaxa @manrum1 Könnte jemand evtl mal die eingepflegten Modbus Adressen Exportieren und Posten das würde vielleicht einigen weiterhelfen! Danke

        metaxa 1 Reply Last reply Reply Quote 0
        • metaxa
          metaxa @TinoNikol last edited by

          @tinonikol Wie/Wo kann ich die exportieren?

          M 1 Reply Last reply Reply Quote 0
          • M
            manrum1 @metaxa last edited by

            @tinonikol Hi, habs über den modbus-Adapter im Expertenmodus exportiert. Solltest du wiede reinlesen können.
            Viel Spaß!

            _address	name	description	unit	type	len	factor	offset	formula	role	room	poll	wp	cw	isScale
            10011	Firmware Version	Firmware Version			1	1	0				true	false	false	false
            10105	Running State	Running State		uint16be	1	1	0		state		true	false	false	false
            10112	Fault FLAG1	Fault FLAG1		uint32be	2	1	0		value		true	false	false	false
            10114	Fault FLAG2	Fault FLAG2		uint32be	2	1	0		value		true	false	false	false
            10994	Phase A Power on Meter	Phase A Power on Meter	W	int32be	2	1	0		value		true	false	false	false
            10996	Phase B Power on Meter	Phase B Power on Meter	W	int32be	2	1	0		value		true	false	false	false
            10998	Phase C Power on Meter	Phase C Power on Meter	W	int32be	2	1	0		value		true	false	false	false
            11000	Zähler (NVP) Leistung	Netz Leistung	W	int32be	2	1	0		value		true	false	false	false
            11002	Total Grid-Injection Energy on Meter	Total Grid-Injection Energy on Meter	kWh	uint32be	2	0,1	0		value		true	false	false	false
            11004	Total Purchasing Energy from Grid on Meter	Total Purchasing Energy from Grid on Meter	kWh	uint32be	2	0,1	0		value		true	false	false	false
            11009	Grid Phase A Voltage	Grid Phase A Voltage	V	uint16be	1	0,1	0		value		true	false	false	false
            11010	Grid Phase A Current	Grid Phase A Current	A	uint16be	1	0,1	0		value		true	false	false	false
            11011	Grid Phase B Voltage	Grid Phase B Voltage	V	uint16be	1	0,1	0		value		true	false	false	false
            11012	Grid Phase B Current	Grid Phase B Current	A	uint16be	1	0,1	0		value		true	false	false	false
            11013	Grid Phase C Voltage	Grid Phase C Voltage	V	uint16be	1	0,1	0		value		true	false	false	false
            11014	Grid Phase C Current	Grid Phase C Current	A	uint16be	1	0,1	0		value		true	false	false	false
            11015	Grid Frequency	Grid Frequency	Hz	uint16be	1	0,01	0		value		true	false	false	false
            11016	AC Leistung Netz	Verbraucher Leistung	W	uint32be	2	1	0		value		true	false	false	false
            11018	Total PV Generation on that day	Total PV Generation on that day	kWh	uint32be	2	0,1	0		value		true	false	false	false
            11020	Total PV Generation from Installation	Total PV Generation from Installation	kWh	uint32be	2	0,1	0		value		true	false	false	false
            11028	PV Leistung	PV Leistung	W	uint32be	2	1	0		value		true	false	false	false
            11032	Temperature Sensor 1	Temperature Sensor 1	°C	int16be	1	0,1	0		value		true	false	false	false
            11033	Temperature Sensor 2	Temperature Sensor 2	°C	int16be	1	0,1	0		value		true	false	false	false
            11034	Temperature Sensor 3	Temperature Sensor 3	°C	int16be	1	0,1	0		value		true	false	false	false
            11035	Temperature Sensor 4	Temperature Sensor 4	°C	int16be	1	0,1	0		value		true	false	false	false
            11038	PV1 Voltage	PV1 Voltage	V	uint16be	1	0,1	0		value		true	false	false	false
            11039	PV1 Currrent	PV1 Currrent	A	uint16be	1	0,1	0		value		true	false	false	false
            11040	PV2 Voltage	PV2 Voltage	V	uint16be	1	0,1	0		value		true	false	false	false
            11041	PV2 Currrent	PV2 Currrent	A	uint16be	1	0,1	0		value		true	false	false	false
            11062	PV1 Input Power	PV1 Input Power	W	uint32be	2	1	0		value		true	false	false	false
            11064	PV2 Input Power	PV2 Input Power	W	uint32be	2	1	0		value		true	false	false	false
            30230	AC Leistung Backup	AC Leistung Backup 	W	int32be	2	1	0		value		true	false	false	false
            30236	Inverter Phase A Active Power	Inverter Phase A Active Power	W	int32be	2	1	0		value		true	false	false	false
            30242	Inverter Phase B Active Power	Inverter Phase A Active Power	W	int32be	2	1	0		value		true	false	false	false
            30248	Inverter Phase C Active Power	Inverter Phase A Active Power	W	int32be	2	1	0		value		true	false	false	false
            30254	Batterie Spannung DC	Batterie Spannung DC	V	uint16be	1	0,1	0		value		true	false	false	false
            30255	Batterie Strom	Batterie Strom	A	int16be	1	0,1	0		value		true	false	false	false
            30256	Batterie Mode	Batterie Mode		uint16be	1	1	0		state		true	false	false	false
            30258	Batterie Leistung	Batterie Leistung	W	int32be	2	1	0		value		true	false	false	false
            31000	Grid Injection today Meter	Grid Injection Energy on that day[Meter]	kWh	uint16be	1	0,1	0		value		true	false	false	false
            31001	Grid Purchasing today Meter	Grid Purchasing Energy on that day[Meter]	kWh	uint16be	1	0,1	0		value		true	false	false	false
            31003	Battery Charge Energy today	Battery Charge Energy today	kWh	uint16be	1	0,1	0		value		true	false	false	false
            31004	Battery Discharge Energy today	Battery Discharge Energy today	kWh	uint16be	1	0,1	0		value		true	false	false	false
            31005	PV Generation today	PV Generation Energy on that day	kWh	uint16be	1	0,1	0		value		true	false	false	false
            31006	Loading Energy today	Loading Energy today	kWh	uint16be	1	0,1	0		value		true	false	false	false
            31008	Energy Purchased from Grid on that day	Energy Purchased from Grid on that day	kWh	uint16be	1	0,1	0		value		true	false	false	false
            31102	Total Energy injected to grid	Total Energy injected to grid	kWh	uint32be	2	0,1	0		value		true	false	false	false
            31104	Total Energy Purchased from Grid Meter	Total Energy Purchased from Grid from Meter	kWh	uint32be	2	0,1	0		value		true	false	false	false
            31108	Total Energy Charged to Battery	Total Energy Charged to Battery	kWh	uint32be	2	0,1	0		value		true	false	false	false
            31110	Total Energy Discharged from Battery	Total Energy Discharged from Battery	kWh	uint32be	2	0,1	0		state		true	false	false	false
            31112	Total PV Generation	Total PV Generation	kWh	uint32be	2	0,1	0		value		true	false	false	false
            31114	Total Loading Energy Consumed at Grid side	Total Loading Energy Consumed at Grid side	kWh	uint32be	2	0,1	0		value		true	false	false	false
            31118	Total Energy Purchased from Grid at Inverter side	Total Energy Purchased from Grid at Inverter side	kWh	uint32be	2	0,1	0		state		true	false	false	false
            33000	SOC	Ladezustand Batterie	%	uint16be	1	0,01	0		value		true	false	false	false
            33001	SOH	Alterrungszustand Batterie	%	uint16be	1	0,01	0		value		true	false	false	false
            33002	BMS Status	BMS Status		uint16be	1	1	0		value		true	false	false	false
            33003	Batterie Temperatur	Batterie Temperatur	°C	uint16be	1	0,1	0		value.temperature		true	false	false	false
            33016	BMS Error	BMS Error		uint32be	2	1	0		state		true	false	false	false
            33018	BMS Warnung	BMS Warnung		uint32be	2	1	0		state		true	false	false	false
            
            1 Reply Last reply Reply Quote 0
            • M
              Merceile last edited by

              Hallo Zusammen,

              ich habe die Verbindung mit Hilfe der Einträge hier im Forum hinbekommen. Vielen Dank dafür. Wie bereits beschrieben wird der Verbrauch nicht korrekt angezeigt. Ich habe nun einen Datenpunkt erstellt habe aber ehrlich gesagt keine Ahnung wie ich werte dort berechnen kann. Meine Versuche mit Blockly funktionieren leider nicht.

              Verbraucher_Leistung = PV_Leistung - Batterie_Leistung - Netz_Leistung (jeweils absolut, also ohne Vorzeichen) (Post von manrum1)

              Hat vielleicht jemand eine Idee oder Vorlage wie ich diesen Datenpunkt mit Werten füttern kann.

              Vielen Dank im Voraus 🙂

              metaxa 1 Reply Last reply Reply Quote 0
              • metaxa
                metaxa @Merceile last edited by

                @merceile sagte in M-TEC Energy Butler:

                Meine Versuche mit Blockly funktionieren leider nicht.

                Zeig mal bitte dein Blockly, welches nicht funktioniert!

                M 1 Reply Last reply Reply Quote 0
                • M
                  Merceile @metaxa last edited by

                  @metaxa Hallo Metaxa,

                  danke für deine Nachricht. Ich habe es in der Zwischenzeit hinbekommen. 🙂
                  Das Ding sieht so aus. Bisher stimmen die Werte. Ich nutze für die Ansicht auf den Displays den Adapter "Energiefluss"

                  blockly.png

                  Vielleicht gibt es ja noch eine schönere Lösung.

                  metaxa 1 Reply Last reply Reply Quote 0
                  • metaxa
                    metaxa @Merceile last edited by

                    @merceile 👍

                    1 Reply Last reply Reply Quote 0
                    • M
                      Merceile last edited by

                      Hallo nochmal,

                      ich habe doch noch eine Frage. Ich habe das Gefühl das mein Blockly-Script doch nicht sauber und korrekt funktioniert. Manchmal stimmt der Wert für den Verbrauch nicht. Es erscheinen Werte die rechnerisch niemals stimmen können. Hat hier jemand vielleicht etwas ähnliches beobachtet? Es geht mir dabei um den aktuellen Verbrauch des Hauses.

                      Wenn ich mich recht erinnere taucht das Verhalten immer dann auf, wenn der Akku geladen wird.

                      Aktuell frage ich die Werte für das Script direkt über den ModBus ab. Ohne Konvertierung oder ähnliches. Vielleicht ist das schon der Fehler.

                      M 1 Reply Last reply Reply Quote 0
                      • M
                        Merceile @Merceile last edited by

                        @merceile Update. Ich habe nun doch einmal mit eigenen Datenpunkten und Konvertierungen gearbeitet. Ob die Werte so stimmen und das Script so funktioniert, kann ich schwer überprüfen.

                        Der Einzige Wert den ich zu 100% prüfen kann, ist der Stromzähler. Alles Weitere kommt dann von Mtec.

                        Blockly2.png

                        1 Reply Last reply Reply Quote 0
                        • KOMAD-bit
                          KOMAD-bit @-FX-RIDER- last edited by

                          @fx-rider Hallo,

                          Ich wollte fragen wo hast du dieses Dokument mit den Registern her? Bzw. gibt es das auch offizielle von M-Tec zum downloaden ?

                          Mit besten Grüßen
                          Katharina

                          1 Reply Last reply Reply Quote 0
                          • First post
                            Last post

                          Support us

                          ioBroker
                          Community Adapters
                          Donate

                          979
                          Online

                          31.7k
                          Users

                          79.8k
                          Topics

                          1.3m
                          Posts

                          21
                          201
                          29650
                          Loading More Posts
                          • Oldest to Newest
                          • Newest to Oldest
                          • Most Votes
                          Reply
                          • Reply as topic
                          Log in to reply
                          Community
                          Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                          The ioBroker Community 2014-2023
                          logo