      1984chris @mickym last edited by

      @mickym
      wenn die Wärmepumpe+Poolpumpe ohne Überschuss laufen sinkt der SOC des Batteriespeichers

      1 1 Reply Last reply Reply Quote 0
      • 1
        1984chris @1984chris last edited by 1984chris

        @1984chris said in Function Node welche zwei Werte vergleicht:

        @mickym
        wenn die Wärmepumpe+Poolpumpe ohne Überschuss laufen sinkt der SOC des Batteriespeichers

        wenn im schlimmsten Fall der SOC unter 80% sinkt schaltet sie die Wärmepumpe+Poolpumpe auch aus.

        Werde den Trigger mal auf 30 min stellen.

        Ich hätte noch eine Frage zur Restlauzeit
        Restlaufzeit_Pumpe.jpg

        wieso wird beim ersten setze msg.delay to the value payload*60000 gesetzt?
        der Wert kommt ja minütlich haben wir ja beim Shelly Polling auf 60000 eingestellt.

        mickym 1 Reply Last reply Reply Quote 0
        • mickym
          mickym Most Active @1984chris last edited by mickym

          @1984chris Genau. Das heißt in die Change Node kommt eine Restlaufzeit als payload in Minuten. Die Nachrichteneigenschaft delay ist für die anschließende Triggernode.

          Diese Triggernode ist ja auf eine Minute eingestellt, wird aber durch msg.delay überschrieben

          6c8afced-82a8-42e2-be21-c2647abc71bf-image.png

          Da die msg.delay aber, wie Du in der Hilfe zur Trigger Node nachlesen kannst, in Millisekunden angegeben wird, muss ich die Minuten Restzeit für die Triggernode in Millisekunden umrechnen. Also 1 Minute Restzeit = 60 Sekunden = 60000 Millisekunden.

          Die Pollzeit aus der Shellynode sorgt ja nur dafür, dass die Restzeit in Minuten verringert wird und auch nur, wenn sie die Switch Node passiert, also der Shelly eingeschaltet ist, da alle Minuten die Shelly Node triggert.

          1 1 Reply Last reply Reply Quote 0
          • mickym
            mickym Most Active @1984chris last edited by

            @1984chris sagte in Function Node welche zwei Werte vergleicht:

            @mickym
            Die Mindestlaufzeit wird jeden Tag um 01:00 wieder auf 360 gesetzt.

            Ja das ist für die Umwälzpumpe, aber für die Wärmepumpe wurde die Laufzeit nicht auf 0 gesetzt.

            1 Reply Last reply Reply Quote 0
            • 1
              1984chris @mickym last edited by

              @mickym
              Danke für die Erklärung.
              Den Fehler habe ich auch gefunden warum heute die Wärmepumpe+Poolpumpe nicht eingeschaltet haben.
              Bei den 3 Bedingungen war AutoEin auf false.
              Glaube das ist gestern passiert als ich am Raspi wo Docker läuft docker attach mynodered eingegeben habe das ich die Logs sehe und mit strg+c habe ich das wieder gestoppt.

              mickym 1 Reply Last reply Reply Quote 0
              • mickym
                mickym Most Active @1984chris last edited by mickym

                @1984chris Wie gesagt, Du musst die Laufzeit der WP auch auf 0 setzen.

                Also würde ich das hier wie folgt abändern - nicht mehr auf die payload - sondern direkt setzen.

                72c5284e-2057-4938-b2fc-63c48c3ff874-image.png

                [{"id":"3f5208fb9a554bb3","type":"inject","z":"517cd16e4d7e6ae4","name":"Täglicher Reset","props":[],"repeat":"","crontab":"00 00 * * *","once":false,"onceDelay":0.1,"topic":"","x":230,"y":4480,"wires":[["ace95e0732cddec2","a3b5991b9f032482"]]},{"id":"ace95e0732cddec2","type":"change","z":"517cd16e4d7e6ae4","name":"","rules":[{"t":"set","p":"RestlaufzeitPoolpumpe","pt":"flow","to":"360","tot":"num"}],"action":"","property":"","from":"","to":"","reg":false,"x":520,"y":4460,"wires":[[]]},{"id":"a3b5991b9f032482","type":"change","z":"517cd16e4d7e6ae4","name":"","rules":[{"t":"set","p":"LaufzeitWP","pt":"flow","to":"0","tot":"num"}],"action":"","property":"","from":"","to":"","reg":false,"x":480,"y":4500,"wires":[[]]}]
                

                oder halt auf 1:00 setzen, ich habs glaub wieder auf 0:00 gesetzt.

                1 1 Reply Last reply Reply Quote 0
                • 1
                  1984chris @mickym last edited by

                  @mickym
                  Du warst schnelle....
                  würde das so auch funktionieren ?WP_Laufzeit_auf 0 setzen.jpg

                  mickym 1 Reply Last reply Reply Quote 0
                  • mickym
                    mickym Most Active @1984chris last edited by mickym

                    @1984chris Ja, ist sogar insofern besser, weil Du auch noch einen reset auf den Trigger & Block Node gleich mitmachst.

                    Ich sehe schon, es macht dir langsam Spaß. 😉

                    1 1 Reply Last reply Reply Quote 0
                    • 1
                      1984chris @mickym last edited by 1984chris

                      @mickym
                      ja sehr sehr langsam...😊

                      Ich verstehe nur eins nicht Die Pumpe ist heute 300 min gelaufen 60 min Pause
                      dann wieder 84 min dann hat sie abgeschalten weil zu wenig Überschuss da war. Aber bei Restlaufzeit steht jetzt noch 1 müsste ja -24 stehen oder?

                      mickym 1 Reply Last reply Reply Quote 0
                      • mickym
                        mickym Most Active @1984chris last edited by

                        @1984chris Ja kann ich mir im Moment auch nicht erklären. Du hast ja eine trigger Node für die Restlaufzeit und mach halt noch eine trigger Node an den anderen Switch Ausgang und schau anhand der Zeitstempel ob es plausibel ist.

                        1 1 Reply Last reply Reply Quote 0
                        • 1
                          1984chris @mickym last edited by

                          @mickym
                          ja kann ich machen.
                          Wird vielleicht sein weil wir die Wärmepumpenlaufzeit nicht um gewisse Uhrzeit XX auf 0 gesetzt haben

                          mickym 1 Reply Last reply Reply Quote 0
                          • mickym
                            mickym Most Active @1984chris last edited by

                            @1984chris Wie gesagt - nun muss man mit Debug oder Inject Nodes - Szenarien simulieren und analysieren.

                            1 Reply Last reply Reply Quote 0
                            • First post
                              Last post

                            Support us

                            ioBroker
                            Community Adapters
                            Donate

                            831
                            Online

                            31.7k
                            Users

                            79.8k
                            Topics

                            1.3m
                            Posts

                            5
                            207
                            19214
                            Loading More Posts
                            • Oldest to Newest
                            • Newest to Oldest
                            • Most Votes
                            Reply
                            • Reply as topic
                            Log in to reply
                            Community
                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                            The ioBroker Community 2014-2023
                            logo