Navigation

    Logo
    • Register
    • Login
    • Search
    • Recent
    • Tags
    • Unread
    • Categories
    • Unreplied
    • Popular
    • GitHub
    • Docu
    • Hilfe
    1. Home
    2. Deutsch
    3. Tester
    4. js-controller Lucy (Version 7.0) jetzt im Beta Repository

    NEWS

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    • Monatsrückblick - April 2025

    js-controller Lucy (Version 7.0) jetzt im Beta Repository

    This topic has been deleted. Only users with topic management privileges can see it.
    • foxriver76
      foxriver76 Developer @DLehmann last edited by

      @dlehmann bitte Controller issue muss gefixt werden

      D 1 Reply Last reply Reply Quote 0
      • D
        DLehmann @foxriver76 last edited by DLehmann

        @foxriver76 erledigt
        issue 2945

        1 Reply Last reply Reply Quote 1
        • foxriver76
          foxriver76 Developer last edited by

          @DLehmann @crunchip eure beiden issues sollten mit Controller 7.0.1 behoben sein.

          Feuersturm D crunchip 3 Replies Last reply Reply Quote 2
          • Feuersturm
            Feuersturm @foxriver76 last edited by

            @foxriver76 Das kommt bei mir, wenn ich per Admin GUI auf 7.0.1 aktualisieren möchte
            0014fda0-34b3-4f4d-9373-2bf75bf197e9-grafik.png

            2024-10-21 20:49:20.372  - info: admin.0 (485) ==> Connected system.user.admin from ::ffff:192.168.178.128
            2024-10-21 20:50:18.176  - info: host.ioB-Prod-Testsystem Controller will upgrade itself to version 7.0.1
            2024-10-21 20:50:23.358  - info: host.ioB-Prod-Testsystem [CONTROLLER_AUTO_UPGRADE] Stopping controller
            2024-10-21 20:50:28.416  - info: host.ioB-Prod-Testsystem [CONTROLLER_AUTO_UPGRADE] Successfully stopped js-controller
            2024-10-21 20:50:28.481  - error: host.ioB-Prod-Testsystem [CONTROLLER_AUTO_UPGRADE] Uncaught Exception: Error: listen EADDRINUSE: address already in use :::8081
                at Server.setupListenHandle [as _listen2] (node:net:1907:16)
                at listenInCluster (node:net:1964:12)
                at Server.listen (node:net:2066:7)
                at UpgradeManager.startInsecureWebServer (file:///opt/iobroker/node_modules/iobroker.js-controller/src/lib/upgradeManager.ts:266:21)
                at UpgradeManager.startWebServer (file:///opt/iobroker/node_modules/iobroker.js-controller/src/lib/upgradeManager.ts:198:18)
                at main (file:///opt/iobroker/node_modules/iobroker.js-controller/src/lib/upgradeManager.ts:400:20)
            
            
            foxriver76 1 Reply Last reply Reply Quote 0
            • foxriver76
              foxriver76 Developer @Feuersturm last edited by

              @feuersturm jedes Mal?

              Feuersturm Dr. Bakterius 2 Replies Last reply Reply Quote 0
              • Feuersturm
                Feuersturm @foxriver76 last edited by Feuersturm

                @foxriver76 sagte in js-controller Lucy (Version 7.0) jetzt im Beta Repository:

                @feuersturm jedes Mal?

                Beim zweiten Mal über die GUI angestartet und der gleiche Fehler.
                Danach über die Konsole und das update war i.O.

                proxmox@ioB-Prod-Testsystem:~$ iob stop
                proxmox@ioB-Prod-Testsystem:~$ iob upgrade self
                Update js-controller from @7.0.0 to @7.0.1
                Stopped Objects DB
                Stopped States DB
                NPM version: 10.9.0
                Installing iobroker.js-controller@7.0.1... (System call)
                
                changed 36 packages in 2m
                
                304 packages are looking for funding
                  run `npm fund` for details
                proxmox@ioB-Prod-Testsystem:~$ iob version
                7.0.1
                
                

                Nachtrag @foxriver76
                der Start sieht nicht gut aus
                Ich hab mein Testsystem gestern auch auf nodejs 22 aktualisiert, kann es auch damit zusammenhängen?

                2024-10-21 21:56:38.148  - info: host.ioB-Prod-Testsystem iobroker.js-controller version 7.0.1 js-controller starting
                2024-10-21 21:56:38.162  - info: host.ioB-Prod-Testsystem Copyright (c) 2014-2024 bluefox, 2014 hobbyquaker
                2024-10-21 21:56:38.167  - info: host.ioB-Prod-Testsystem hostname: ioB-Prod-Testsystem, node: v22.10.0
                2024-10-21 21:56:38.172  - info: host.ioB-Prod-Testsystem ip addresses: 192.168.178.105 fe80::be24:11ff:fe8c:71a4
                2024-10-21 21:56:41.544  - info: host.ioB-Prod-Testsystem connected to Objects and States
                2024-10-21 21:56:41.621  - info: host.ioB-Prod-Testsystem added notifications configuration of host
                2024-10-21 21:56:43.079  - info: host.ioB-Prod-Testsystem 68 instances found
                2024-10-21 21:56:43.254  - info: host.ioB-Prod-Testsystem starting 48 instances
                2024-10-21 21:56:44.379  - info: host.ioB-Prod-Testsystem Delete state "system.host.ioB-Prod-Testsystem.versions.nodeCurrent"
                2024-10-21 21:56:44.667  - info: host.ioB-Prod-Testsystem Delete state "system.host.ioB-Prod-Testsystem.versions.nodeNewest"
                2024-10-21 21:56:44.717  - info: host.ioB-Prod-Testsystem instance system.adapter.admin.0 in version "7.2.6" started with pid 26711
                2024-10-21 21:56:44.734  - info: host.ioB-Prod-Testsystem Delete state "system.host.ioB-Prod-Testsystem.versions.nodeNewestNext"
                2024-10-21 21:56:44.792  - info: host.ioB-Prod-Testsystem Delete state "system.host.ioB-Prod-Testsystem.versions.npmCurrent"
                2024-10-21 21:56:44.808  - info: host.ioB-Prod-Testsystem Delete state "system.host.ioB-Prod-Testsystem.versions.npmNewest"
                2024-10-21 21:56:44.832  - info: host.ioB-Prod-Testsystem Delete state "system.host.ioB-Prod-Testsystem.versions.npmNewestNext"
                2024-10-21 21:56:44.849  - info: host.ioB-Prod-Testsystem Some obsolete host states deleted.
                2024-10-21 21:56:48.189  - info: host.ioB-Prod-Testsystem instance system.adapter.javascript.0 in version "8.8.3" started with pid 26718
                2024-10-21 21:56:52.302  - info: host.ioB-Prod-Testsystem instance system.adapter.scenes.0 in version "3.2.3" started with pid 26733
                2024-10-21 21:56:52.702  - info: admin.0 (26711) starting. Version 7.2.6 in /opt/iobroker/node_modules/iobroker.admin, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:56:52.812  - info: admin.0 (26711) requesting all objects
                2024-10-21 21:56:56.011  - info: admin.0 (26711) received all objects
                2024-10-21 21:56:56.460  - info: host.ioB-Prod-Testsystem instance system.adapter.scheduler.0 in version "1.4.1" started with pid 26763
                2024-10-21 21:56:56.968  - info: admin.0 (26711) socket.io server listening on port 8081
                2024-10-21 21:56:56.989  - info: admin.0 (26711) http server listening on port 8081
                2024-10-21 21:56:56.998  - info: admin.0 (26711) Use link "http://127.0.0.1:8081" to configure.
                2024-10-21 21:56:59.961  - error: admin.0 (26711) uncaught exception: write EPIPE
                2024-10-21 21:56:59.975  - error: admin.0 (26711) Error: write EPIPE
                    at afterWriteDispatched (node:internal/stream_base_commons:159:15)
                    at writeGeneric (node:internal/stream_base_commons:150:3)
                    at Socket._writeGeneric (node:net:957:11)
                    at Socket._write (node:net:969:8)
                    at writeOrBuffer (node:internal/streams/writable:572:12)
                    at _write (node:internal/streams/writable:501:10)
                    at Socket.Writable.write (node:internal/streams/writable:510:10)
                    at _checkPassword (/opt/iobroker/node_modules/iobroker.admin/src/lib/checkLinuxPass.ts:43:30)
                    at Socket.<anonymous> (/opt/iobroker/node_modules/iobroker.admin/src/lib/checkLinuxPass.ts:61:42)
                    at Socket.emit (node:events:518:28)
                2024-10-21 21:56:59.988  - error: admin.0 (26711) Exception-Code: EPIPE: write EPIPE
                2024-10-21 21:57:00.797  - info: admin.0 (26711) terminating http server on port 8081
                2024-10-21 21:57:02.449  - error: host.ioB-Prod-Testsystem Caught by controller[0]: Error: write EPIPE
                2024-10-21 21:57:02.454  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at afterWriteDispatched (node:internal/stream_base_commons:159:15)
                2024-10-21 21:57:02.457  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at writeGeneric (node:internal/stream_base_commons:150:3)
                2024-10-21 21:57:02.460  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Socket._writeGeneric (node:net:957:11)
                2024-10-21 21:57:02.463  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Socket._write (node:net:969:8)
                2024-10-21 21:57:02.466  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at writeOrBuffer (node:internal/streams/writable:572:12)
                2024-10-21 21:57:02.470  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at _write (node:internal/streams/writable:501:10)
                2024-10-21 21:57:02.473  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Socket.Writable.write (node:internal/streams/writable:510:10)
                2024-10-21 21:57:02.476  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at _checkPassword (/opt/iobroker/node_modules/iobroker.admin/src/lib/checkLinuxPass.ts:43:30)
                2024-10-21 21:57:02.479  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Socket.<anonymous> (/opt/iobroker/node_modules/iobroker.admin/src/lib/checkLinuxPass.ts:61:42)
                2024-10-21 21:57:02.482  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Socket.emit (node:events:518:28) {
                2024-10-21 21:57:02.485  - error: host.ioB-Prod-Testsystem Caught by controller[0]:   errno: -32,
                2024-10-21 21:57:02.488  - error: host.ioB-Prod-Testsystem Caught by controller[0]:   code: 'EPIPE',
                2024-10-21 21:57:02.491  - error: host.ioB-Prod-Testsystem Caught by controller[0]:   syscall: 'write'
                2024-10-21 21:57:02.494  - error: host.ioB-Prod-Testsystem Caught by controller[0]: }
                2024-10-21 21:57:02.498  - error: host.ioB-Prod-Testsystem instance system.adapter.admin.0 terminated with code 1 (JS_CONTROLLER_STOPPED)
                2024-10-21 21:57:02.501  - info: host.ioB-Prod-Testsystem Restart adapter system.adapter.admin.0 because enabled
                2024-10-21 21:57:02.937  - info: host.ioB-Prod-Testsystem instance system.adapter.fritzbox.0 in version "0.6.0" started with pid 26795
                2024-10-21 21:57:03.054  - info: javascript.0 (26718) starting. Version 8.8.3 in /opt/iobroker/node_modules/iobroker.javascript, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:57:03.164  - info: scenes.0 (26733) starting. Version 3.2.3 in /opt/iobroker/node_modules/iobroker.scenes, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:57:05.653  - info: host.ioB-Prod-Testsystem instance system.adapter.hm-rpc.0 in version "2.0.2" started with pid 26821
                2024-10-21 21:57:06.878  - info: scheduler.0 (26763) starting. Version 1.4.1 in /opt/iobroker/node_modules/iobroker.scheduler, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:57:08.737  - info: host.ioB-Prod-Testsystem instance system.adapter.hm-rega.0 in version "5.1.0" started with pid 26840
                2024-10-21 21:57:12.555  - info: fritzbox.0 (26795) starting. Version 0.6.0 in /opt/iobroker/node_modules/iobroker.fritzbox, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:57:12.637  - info: host.ioB-Prod-Testsystem instance system.adapter.proxmox.0 in version "2.3.0" started with pid 26849
                2024-10-21 21:57:12.691  - info: fritzbox.0 (26795) try to connect: 192.168.178.1
                2024-10-21 21:57:12.725  - info: fritzbox.0 (26795) adapter connected to fritzbox: 192.168.178.1
                2024-10-21 21:57:12.991  - info: hm-rpc.0 (26821) starting. Version 2.0.2 in /opt/iobroker/node_modules/iobroker.hm-rpc, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:57:14.095  - info: hm-rpc.0 (26821) xmlrpc server is trying to listen on 192.168.178.105:2010
                2024-10-21 21:57:14.103  - info: hm-rpc.0 (26821) xmlrpc client is trying to connect to 192.168.178.84:2010/ with ["http://192.168.178.105:2010","ioB-Prod-Testsystem:hm-rpc.0:1a421c1408aefa3d14bf662ce872a30f"]
                2024-10-21 21:57:14.208  - info: hm-rpc.0 (26821) Connected
                2024-10-21 21:57:14.229  - info: hm-rpc.0 (26821) xmlrpc <- listDevices ["ioB-Prod-Testsystem:hm-rpc.0:1a421c1408aefa3d14bf662ce872a30f"]
                2024-10-21 21:57:14.549  - info: hm-rpc.0 (26821) xmlrpc -> 0 devices
                2024-10-21 21:57:16.196  - info: hm-rpc.0 (26821) xmlrpc <- newDevices 323
                2024-10-21 21:57:16.792  - info: host.ioB-Prod-Testsystem instance system.adapter.tr-064.0 in version "4.3.0" started with pid 26870
                2024-10-21 21:57:16.820  - info: hm-rpc.0 (26821) new HMIP devices/channels after filter: 0
                2024-10-21 21:57:21.531  - info: host.ioB-Prod-Testsystem instance system.adapter.worx.0 in version "3.1.0" started with pid 26877
                2024-10-21 21:57:22.200  - info: hm-rega.0 (26840) starting. Version 5.1.0 in /opt/iobroker/node_modules/iobroker.hm-rega, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:57:22.912  - info: hm-rega.0 (26840) subscribe .BidCoS-RF.50.PRESS_SHORT
                2024-10-21 21:57:22.926  - info: proxmox.0 (26849) starting. Version 2.3.0 in /opt/iobroker/node_modules/iobroker.proxmox, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:57:23.140  - info: hm-rega.0 (26840) ReGaHSS 192.168.178.84 up
                2024-10-21 21:57:23.443  - info: hm-rega.0 (26840) time difference local-ccu 0s
                2024-10-21 21:57:23.047  - warn: proxmox.0 (26849) Using Proxmox API: https://192.168.178.2:8006/api2/json
                2024-10-21 21:57:25.883  - info: host.ioB-Prod-Testsystem instance system.adapter.unifi.0 in version "0.7.0" started with pid 26896
                2024-10-21 21:57:29.111  - info: host.ioB-Prod-Testsystem instance system.adapter.hue.0 in version "3.13.1" started with pid 26907
                2024-10-21 21:57:30.587  - info: tr-064.0 (26870) starting. Version 4.3.0 in /opt/iobroker/node_modules/iobroker.tr-064, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:57:34.704  - info: host.ioB-Prod-Testsystem instance system.adapter.backitup.0 in version "3.0.26" started with pid 26926
                2024-10-21 21:57:34.825  - info: host.ioB-Prod-Testsystem instance system.adapter.admin.0 in version "7.2.6" started with pid 26933
                2024-10-21 21:57:37.045  - info: host.ioB-Prod-Testsystem instance system.adapter.hm-rpc.1 in version "2.0.2" started with pid 26940
                2024-10-21 21:57:37.837  - info: worx.0 (26877) starting. Version 3.1.0 in /opt/iobroker/node_modules/iobroker.worx, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:57:38.814  - info: worx.0 (26877) Use new aws-iot-device-sdk-v2.
                2024-10-21 21:57:38.842  - info: worx.0 (26877) Changed timeout for edgecut to 5000
                2024-10-21 21:57:38.905  - info: worx.0 (26877) Login to worx
                2024-10-21 21:57:41.182  - info: worx.0 (26877) Connected to worx server
                2024-10-21 21:57:41.548  - info: worx.0 (26877) Found 1 devices
                2024-10-21 21:57:41.578  - info: worx.0 (26877) Found device Maehphisto with id 201930198403020782E0
                2024-10-21 21:57:42.761  - info: host.ioB-Prod-Testsystem instance system.adapter.sonos.0 in version "3.0.0" started with pid 26957
                2024-10-21 21:57:46.104  - info: host.ioB-Prod-Testsystem instance scheduled system.adapter.openweathermap.0 10 * * * *
                2024-10-21 21:57:46.132  - info: host.ioB-Prod-Testsystem instance system.adapter.openweathermap.0 in version "1.1.2" started with pid 26972
                2024-10-21 21:57:46.510  - info: hue.0 (26907) starting. Version 3.13.1 in /opt/iobroker/node_modules/iobroker.hue, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:57:46.510  - info: unifi.0 (26896) starting. Version 0.7.0 in /opt/iobroker/node_modules/iobroker.unifi, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:57:46.632  - info: unifi.0 (26896) UniFi adapter is ready
                2024-10-21 21:57:48.158  - info: hue.0 (26907) Push connection established
                2024-10-21 21:57:49.435  - info: hue.0 (26907) skip switch: Daylight.configured
                2024-10-21 21:57:49.447  - info: hue.0 (26907) skip switch: Daylight.sunriseoffset
                2024-10-21 21:57:49.453  - info: hue.0 (26907) skip switch: Daylight.sunsetoffset
                2024-10-21 21:57:49.458  - info: hue.0 (26907) created/updated 1 sensor channels
                2024-10-21 21:57:49.515  - info: host.ioB-Prod-Testsystem instance scheduled system.adapter.ical.5 0,30 * * * *
                2024-10-21 21:57:49.557  - info: host.ioB-Prod-Testsystem instance system.adapter.ical.5 in version "1.15.0" started with pid 26991
                2024-10-21 21:57:49.591  - info: worx.0 (26877) Multi-ZoneKeeper found! Create State : zoneKeeper
                2024-10-21 21:57:50.063  - warn: hue.0 (26907) channel "Tannenbaum" already exists, using "Tannenbaum_On/Off_plug-in_unit" for light 15
                2024-10-21 21:57:50.213  - info: worx.0 (26877) DoubleShedule found, create states...
                2024-10-21 21:57:50.289  - info: hue.0 (26907) created/updated 13 light channels
                2024-10-21 21:57:50.440  - warn: hue.0 (26907) channel "Hannah" already exists, using "Hannah_Room" for group 4
                2024-10-21 21:57:50.630  - info: hue.0 (26907) created/updated 9 groups channels
                2024-10-21 21:57:50.676  - info: hue.0 (26907) created/updated 23 scenes
                2024-10-21 21:57:50.685  - info: hue.0 (26907) creating/updating bridge device
                2024-10-21 21:57:52.904  - info: worx.0 (26877) OneTimeShedule found, create states...
                2024-10-21 21:57:53.022  - info: hm-rega.0 (26840) request state values
                2024-10-21 21:57:53.275  - info: worx.0 (26877) PartyModus found, create states...
                2024-10-21 21:57:53.518  - info: host.ioB-Prod-Testsystem instance system.adapter.samsung.0 in version "0.6.1" started with pid 27002
                2024-10-21 21:57:53.668  - info: worx.0 (26877) New Firmware found, create states...
                2024-10-21 21:57:54.265  - info: worx.0 (26877) Create folder activityLog and set states.
                2024-10-21 21:57:54.323  - info: sonos.0 (26957) starting. Version 3.0.0 in /opt/iobroker/node_modules/iobroker.sonos, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:57:54.683  - info: backitup.0 (26926) starting. Version 3.0.26 in /opt/iobroker/node_modules/iobroker.backitup, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:57:54.997  - info: worx.0 (26877) Create product folder and states for WR141E
                2024-10-21 21:57:55.154  - info: hm-rpc.1 (26940) starting. Version 2.0.2 in /opt/iobroker/node_modules/iobroker.hm-rpc, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:57:55.243  - info: backitup.0 (26926) [iobroker] backup will be activated at 05:00 every 1 day(s)
                2024-10-21 21:57:55.530  - info: backitup.0 (26926) [ccu] backup will be activated at 01:30 every 3 day(s)
                2024-10-21 21:57:58.681  - info: hm-rpc.1 (26940) xmlrpc server is trying to listen on 192.168.178.105:9292
                2024-10-21 21:57:58.694  - info: hm-rpc.1 (26940) xmlrpc client is trying to connect to 192.168.178.84:9292/groups/ with ["http://192.168.178.105:9292","ioB-Prod-Testsystem:hm-rpc.1:10da2ed2497e0ac55ceb41380a836a0d"]
                2024-10-21 21:57:58.819  - info: hm-rpc.1 (26940) xmlrpc <- listDevices ["ioB-Prod-Testsystem:hm-rpc.1:10da2ed2497e0ac55ceb41380a836a0d"]
                2024-10-21 21:57:59.776  - info: hm-rpc.1 (26940) xmlrpc -> 8 devices
                2024-10-21 21:58:00.154  - info: hm-rpc.1 (26940) xmlrpc <- newDevices 8
                2024-10-21 21:58:01.300  - info: admin.0 (26933) starting. Version 7.2.6 in /opt/iobroker/node_modules/iobroker.admin, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:58:01.369  - info: hm-rpc.1 (26940) new virtual-devices devices/channels after filter: 0
                2024-10-21 21:58:01.414  - info: hm-rpc.1 (26940) xmlrpc <- setReadyConfig ["ioB-Prod-Testsystem:hm-rpc.1:10da2ed2497e0ac55ceb41380a836a0d","INT0000001"]
                2024-10-21 21:58:01.777  - info: host.ioB-Prod-Testsystem instance system.adapter.notification-manager.0 in version "1.3.0" started with pid 27029
                2024-10-21 21:58:02.018  - info: admin.0 (26933) requesting all objects
                2024-10-21 21:58:02.576  - info: host.ioB-Prod-Testsystem instance system.adapter.web.0 in version "6.3.1" started with pid 27036
                2024-10-21 21:58:08.612  - info: admin.0 (26933) received all objects
                2024-10-21 21:58:08.822  - info: hm-rpc.1 (26940) Connected
                2024-10-21 21:58:11.239  - info: admin.0 (26933) socket.io server listening on port 8081
                2024-10-21 21:58:11.261  - info: admin.0 (26933) http server listening on port 8081
                2024-10-21 21:58:11.266  - info: admin.0 (26933) Use link "http://127.0.0.1:8081" to configure.
                2024-10-21 21:58:23.247  - info: host.ioB-Prod-Testsystem instance system.adapter.tankerkoenig.0 in version "3.4.0" started with pid 27076
                2024-10-21 21:58:23.828  - info: host.ioB-Prod-Testsystem instance scheduled system.adapter.daswetter.0 0 */2 * * *
                2024-10-21 21:58:23.857  - info: host.ioB-Prod-Testsystem instance system.adapter.daswetter.0 in version "3.1.16" started with pid 27083
                2024-10-21 21:58:26.262  - info: host.ioB-Prod-Testsystem instance scheduled system.adapter.dwd.0 */30 * * * *
                2024-10-21 21:58:26.310  - info: host.ioB-Prod-Testsystem instance system.adapter.dwd.0 in version "2.8.5" started with pid 27090
                2024-10-21 21:58:27.258  - info: host.ioB-Prod-Testsystem instance system.adapter.trashschedule.0 in version "3.3.0" started with pid 27101
                2024-10-21 21:58:34.864  - info: host.ioB-Prod-Testsystem instance system.adapter.simple-api.0 in version "2.8.0" started with pid 27127
                2024-10-21 21:58:36.494  - info: host.ioB-Prod-Testsystem instance system.adapter.nina.0 in version "0.0.26" started with pid 27134
                2024-10-21 21:58:38.748  - info: vis.0 (27065) starting. Version 1.5.6 in /opt/iobroker/node_modules/iobroker.vis, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:58:42.398  - info: host.ioB-Prod-Testsystem instance system.adapter.esphome.0 in version "0.5.0-beta.8" started with pid 27153
                2024-10-21 21:58:46.882  - info: notification-manager.0 (27029) starting. Version 1.3.0 in /opt/iobroker/node_modules/iobroker.notification-manager, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:58:47.012  - info: notification-manager.0 (27029) Starting notification manager ...
                2024-10-21 21:58:47.762  - info: samsung.0 (27002) starting. Version 0.6.1 in /opt/iobroker/node_modules/iobroker.samsung, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:58:50.345  - info: host.ioB-Prod-Testsystem instance system.adapter.ws.0 in version "2.6.2" started with pid 27177
                2024-10-21 21:58:52.055  - info: host.ioB-Prod-Testsystem instance system.adapter.fully-tablet-control.0 in version "0.3.8" started with pid 27184
                2024-10-21 21:58:52.256  - info: vis-google-fonts.0 (27116) starting. Version 1.0.4 in /opt/iobroker/node_modules/iobroker.vis-google-fonts, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:58:53.742  - info: vis.0 (27065) Terminated (NO_ERROR): Without reason
                2024-10-21 21:58:53.806  - info: host.ioB-Prod-Testsystem instance system.adapter.web.1 in version "6.3.1" started with pid 27195
                2024-10-21 21:58:54.267  - info: ical.5 (26991) starting. Version 1.15.0 in /opt/iobroker/node_modules/iobroker.ical, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:58:55.092  - info: vis-google-fonts.0 (27116) Terminated (NO_ERROR): Without reason
                2024-10-21 21:58:55.164  - info: host.ioB-Prod-Testsystem instance system.adapter.fullcalendar.0 in version "2.4.5" started with pid 27210
                2024-10-21 21:58:56.440  - info: web.0 (27036) starting. Version 6.3.1 in /opt/iobroker/node_modules/iobroker.web, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:58:56.765  - info: ical.5 (26991) processing URL: ioBrokerTesting https://calendar.google.com/calendar/ical/0g7gpl8tcsjsbacjrkunfg8l0c%40group.calendar.google.com/private-ee9dd402778b56aafd5eea5e6f591bd6/basic.ics
                2024-10-21 21:58:56.980  - info: host.ioB-Prod-Testsystem instance system.adapter.vis.0 terminated while should be started once
                2024-10-21 21:58:58.853  - info: worx.0 (26877) Torque control found, create states...
                2024-10-21 21:59:00.222  - info: web.0 (27036) socket.io server listening on port 8082
                2024-10-21 21:59:00.330  - info: web.0 (27036) http server listening on port 8082
                2024-10-21 21:59:04.276  - info: worx.0 (26877) Autolock found! Create State : AutoLock
                2024-10-21 21:59:04.480  - info: worx.0 (26877) Autolock found! Create State : AutoLockTimer
                2024-10-21 21:59:05.285  - info: host.ioB-Prod-Testsystem instance system.adapter.vis-google-fonts.0 terminated while should be started once
                2024-10-21 21:59:06.770  - info: daswetter.0 (27083) starting. Version 3.1.16 in /opt/iobroker/node_modules/iobroker.daswetter, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:59:07.275  - info: host.ioB-Prod-Testsystem instance system.adapter.vis-2.0 in version "2.9.64" started with pid 27237
                2024-10-21 21:59:07.328  - info: host.ioB-Prod-Testsystem instance system.adapter.echarts.0 in version "1.9.2" started with pid 27243
                2024-10-21 21:59:07.896  - info: worx.0 (26877) Start MQTT connection
                2024-10-21 21:59:07.896  - info: worx.0 (26877) Start MQTT connection
                2024-10-21 21:59:07.894  - info: tankerkoenig.0 (27076) starting. Version 3.4.0 in /opt/iobroker/node_modules/iobroker.tankerkoenig, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:59:08.139  - info: host.ioB-Prod-Testsystem instance system.adapter.radar-trap.0 in version "2.2.2" started with pid 27255
                2024-10-21 21:59:08.188  - info: tankerkoenig.0 (27076) Adapter is already in daemon mode
                2024-10-21 21:59:08.211  - info: tankerkoenig.0 (27076) Sync time set to 10 minutes or 600000 ms
                2024-10-21 21:59:08.362  - info: worx.0 (26877) Start check devices object!
                2024-10-21 21:59:08.801  - info: worx.0 (26877) Request Counter: 1
                2024-10-21 21:59:08.829  - info: openweathermap.0 (26972) starting. Version 1.1.2 in /opt/iobroker/node_modules/iobroker.openweathermap, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:59:10.988  - info: nina.0 (27134) starting. Version 0.0.26 in /opt/iobroker/node_modules/iobroker.nina, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:59:11.209  - info: simple-api.0 (27127) starting. Version 2.8.0 in /opt/iobroker/node_modules/iobroker.simple-api, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:59:11.450  - info: simple-api.0 (27127) simpleAPI server listening on port 8087
                2024-10-21 21:59:11.469  - info: simple-api.0 (27127) Allow states only when user is owner: false
                2024-10-21 21:59:11.580  - info: simple-api.0 (27127) http server listening on port 8087
                2024-10-21 21:59:11.939  - info: nina.0 (27134) Found AGS for: Braunschweig
                2024-10-21 21:59:14.241  - info: esphome.0 (27153) starting. Version 0.5.0-beta.8 in /opt/iobroker/node_modules/iobroker.esphome, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:59:14.412  - info: ical.5 (26991) Terminated (NO_ERROR): Without reason
                2024-10-21 21:59:17.993  - error: host.ioB-Prod-Testsystem Caught by controller[0]: node:internal/modules/cjs/loader:1252
                2024-10-21 21:59:18.006  - error: host.ioB-Prod-Testsystem Caught by controller[0]:   throw err;
                2024-10-21 21:59:18.010  - error: host.ioB-Prod-Testsystem Caught by controller[0]:   ^
                2024-10-21 21:59:18.014  - error: host.ioB-Prod-Testsystem Caught by controller[0]: Error: Cannot find module '@iobroker/types'
                2024-10-21 21:59:18.020  - error: host.ioB-Prod-Testsystem Caught by controller[0]: Require stack:
                2024-10-21 21:59:18.024  - error: host.ioB-Prod-Testsystem Caught by controller[0]: - /opt/iobroker/node_modules/@iobroker/adapter-core/build/cjs/index.js
                2024-10-21 21:59:18.031  - error: host.ioB-Prod-Testsystem Caught by controller[0]: - /opt/iobroker/node_modules/iobroker.vis-2/main.js
                2024-10-21 21:59:18.038  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Function._resolveFilename (node:internal/modules/cjs/loader:1249:15)
                2024-10-21 21:59:18.043  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Function._load (node:internal/modules/cjs/loader:1075:27)
                2024-10-21 21:59:18.048  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at TracingChannel.traceSync (node:diagnostics_channel:315:14)
                2024-10-21 21:59:18.055  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at wrapModuleLoad (node:internal/modules/cjs/loader:218:24)
                2024-10-21 21:59:18.061  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Module.require (node:internal/modules/cjs/loader:1340:12)
                2024-10-21 21:59:18.070  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at require (node:internal/modules/helpers:141:16)
                2024-10-21 21:59:18.083  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Object.<anonymous> (/opt/iobroker/node_modules/@iobroker/adapter-core/build/cjs/index.js:37:20)
                2024-10-21 21:59:18.096  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Module._compile (node:internal/modules/cjs/loader:1546:14)
                2024-10-21 21:59:18.107  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Object..js (node:internal/modules/cjs/loader:1689:10)
                2024-10-21 21:59:18.123  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Module.load (node:internal/modules/cjs/loader:1318:32) {
                2024-10-21 21:59:18.139  - error: host.ioB-Prod-Testsystem Caught by controller[0]:   code: 'MODULE_NOT_FOUND',
                2024-10-21 21:59:18.166  - error: host.ioB-Prod-Testsystem Caught by controller[0]:   requireStack: [
                2024-10-21 21:59:18.178  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     '/opt/iobroker/node_modules/@iobroker/adapter-core/build/cjs/index.js',
                2024-10-21 21:59:18.200  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     '/opt/iobroker/node_modules/iobroker.vis-2/main.js'
                2024-10-21 21:59:18.212  - error: host.ioB-Prod-Testsystem Caught by controller[0]:   ]
                2024-10-21 21:59:18.224  - error: host.ioB-Prod-Testsystem Caught by controller[0]: }
                2024-10-21 21:59:18.238  - error: host.ioB-Prod-Testsystem Caught by controller[0]: Node.js v22.10.0
                2024-10-21 21:59:18.254  - error: host.ioB-Prod-Testsystem instance system.adapter.vis-2.0 terminated with code 1 (JS_CONTROLLER_STOPPED)
                2024-10-21 21:59:18.268  - info: host.ioB-Prod-Testsystem Adapter system.adapter.vis-2.0 needs rebuild and will be restarted afterwards.
                2024-10-21 21:59:18.283  - info: host.ioB-Prod-Testsystem system.adapter.vis-2.0 will be rebuilt
                2024-10-21 21:59:18.302  - warn: host.ioB-Prod-Testsystem adapter "vis-2" seems to be installed for a different version of Node.js. Trying to rebuild it... 1 attempt
                2024-10-21 21:59:18.323  - info: host.ioB-Prod-Testsystem iobroker rebuild
                2024-10-21 21:59:18.672  - error: host.ioB-Prod-Testsystem Caught by controller[0]: node:internal/modules/cjs/loader:1252
                2024-10-21 21:59:18.681  - error: host.ioB-Prod-Testsystem Caught by controller[0]:   throw err;
                2024-10-21 21:59:18.696  - error: host.ioB-Prod-Testsystem Caught by controller[0]:   ^
                2024-10-21 21:59:18.708  - error: host.ioB-Prod-Testsystem Caught by controller[0]: Error: Cannot find module '@iobroker/types'
                2024-10-21 21:59:18.722  - error: host.ioB-Prod-Testsystem Caught by controller[0]: Require stack:
                2024-10-21 21:59:18.735  - error: host.ioB-Prod-Testsystem Caught by controller[0]: - /opt/iobroker/node_modules/@iobroker/adapter-core/build/cjs/index.js
                2024-10-21 21:59:18.743  - error: host.ioB-Prod-Testsystem Caught by controller[0]: - /opt/iobroker/node_modules/iobroker.echarts/main.js
                2024-10-21 21:59:18.750  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Function._resolveFilename (node:internal/modules/cjs/loader:1249:15)
                2024-10-21 21:59:18.758  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Function._load (node:internal/modules/cjs/loader:1075:27)
                2024-10-21 21:59:18.766  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at TracingChannel.traceSync (node:diagnostics_channel:315:14)
                2024-10-21 21:59:18.775  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at wrapModuleLoad (node:internal/modules/cjs/loader:218:24)
                2024-10-21 21:59:18.782  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Module.require (node:internal/modules/cjs/loader:1340:12)
                2024-10-21 21:59:18.789  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at require (node:internal/modules/helpers:141:16)
                2024-10-21 21:59:18.798  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Object.<anonymous> (/opt/iobroker/node_modules/@iobroker/adapter-core/build/cjs/index.js:37:20)
                2024-10-21 21:59:18.806  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Module._compile (node:internal/modules/cjs/loader:1546:14)
                2024-10-21 21:59:18.816  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Object..js (node:internal/modules/cjs/loader:1689:10)
                2024-10-21 21:59:18.823  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Module.load (node:internal/modules/cjs/loader:1318:32) {
                2024-10-21 21:59:18.835  - error: host.ioB-Prod-Testsystem Caught by controller[0]:   code: 'MODULE_NOT_FOUND',
                2024-10-21 21:59:18.843  - error: host.ioB-Prod-Testsystem Caught by controller[0]:   requireStack: [
                2024-10-21 21:59:18.855  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     '/opt/iobroker/node_modules/@iobroker/adapter-core/build/cjs/index.js',
                2024-10-21 21:59:18.865  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     '/opt/iobroker/node_modules/iobroker.echarts/main.js'
                2024-10-21 21:59:18.873  - error: host.ioB-Prod-Testsystem Caught by controller[0]:   ]
                2024-10-21 21:59:18.880  - error: host.ioB-Prod-Testsystem Caught by controller[0]: }
                2024-10-21 21:59:18.887  - error: host.ioB-Prod-Testsystem Caught by controller[0]: Node.js v22.10.0
                2024-10-21 21:59:18.902  - error: host.ioB-Prod-Testsystem instance system.adapter.echarts.0 terminated with code 1 (JS_CONTROLLER_STOPPED)
                2024-10-21 21:59:18.909  - info: host.ioB-Prod-Testsystem Adapter system.adapter.echarts.0 needs rebuild and will be restarted afterwards.
                2024-10-21 21:59:18.917  - info: host.ioB-Prod-Testsystem system.adapter.echarts.0 will be rebuilt
                2024-10-21 21:59:19.302  - error: host.ioB-Prod-Testsystem Caught by controller[0]: node:internal/modules/cjs/loader:1252
                2024-10-21 21:59:19.320  - error: host.ioB-Prod-Testsystem Caught by controller[0]:   throw err;
                2024-10-21 21:59:19.334  - error: host.ioB-Prod-Testsystem Caught by controller[0]:   ^
                2024-10-21 21:59:19.344  - error: host.ioB-Prod-Testsystem Caught by controller[0]: Error: Cannot find module '@iobroker/types'
                2024-10-21 21:59:19.356  - error: host.ioB-Prod-Testsystem Caught by controller[0]: Require stack:
                2024-10-21 21:59:19.366  - error: host.ioB-Prod-Testsystem Caught by controller[0]: - /opt/iobroker/node_modules/@iobroker/adapter-core/build/cjs/index.js
                2024-10-21 21:59:19.375  - error: host.ioB-Prod-Testsystem Caught by controller[0]: - /opt/iobroker/node_modules/iobroker.radar-trap/build/main.js
                2024-10-21 21:59:19.383  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Function._resolveFilename (node:internal/modules/cjs/loader:1249:15)
                2024-10-21 21:59:19.399  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Function._load (node:internal/modules/cjs/loader:1075:27)
                2024-10-21 21:59:19.404  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at TracingChannel.traceSync (node:diagnostics_channel:315:14)
                2024-10-21 21:59:19.415  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at wrapModuleLoad (node:internal/modules/cjs/loader:218:24)
                2024-10-21 21:59:19.420  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Module.require (node:internal/modules/cjs/loader:1340:12)
                2024-10-21 21:59:19.427  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at require (node:internal/modules/helpers:141:16)
                2024-10-21 21:59:19.435  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Object.<anonymous> (/opt/iobroker/node_modules/@iobroker/adapter-core/build/cjs/index.js:37:20)
                2024-10-21 21:59:19.442  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Module._compile (node:internal/modules/cjs/loader:1546:14)
                2024-10-21 21:59:19.449  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Object..js (node:internal/modules/cjs/loader:1689:10)
                2024-10-21 21:59:19.456  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     at Module.load (node:internal/modules/cjs/loader:1318:32) {
                2024-10-21 21:59:19.462  - error: host.ioB-Prod-Testsystem Caught by controller[0]:   code: 'MODULE_NOT_FOUND',
                2024-10-21 21:59:19.469  - error: host.ioB-Prod-Testsystem Caught by controller[0]:   requireStack: [
                2024-10-21 21:59:19.478  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     '/opt/iobroker/node_modules/@iobroker/adapter-core/build/cjs/index.js',
                2024-10-21 21:59:19.488  - error: host.ioB-Prod-Testsystem Caught by controller[0]:     '/opt/iobroker/node_modules/iobroker.radar-trap/build/main.js'
                2024-10-21 21:59:19.496  - error: host.ioB-Prod-Testsystem Caught by controller[0]:   ]
                2024-10-21 21:59:19.510  - error: host.ioB-Prod-Testsystem Caught by controller[0]: }
                2024-10-21 21:59:19.518  - error: host.ioB-Prod-Testsystem Caught by controller[0]: Node.js v22.10.0
                2024-10-21 21:59:19.525  - error: host.ioB-Prod-Testsystem instance system.adapter.radar-trap.0 terminated with code 1 (JS_CONTROLLER_STOPPED)
                2024-10-21 21:59:19.533  - info: host.ioB-Prod-Testsystem Adapter system.adapter.radar-trap.0 needs rebuild and will be restarted afterwards.
                2024-10-21 21:59:19.546  - info: host.ioB-Prod-Testsystem system.adapter.radar-trap.0 will be rebuilt
                2024-10-21 21:59:20.526  - info: host.ioB-Prod-Testsystem instance system.adapter.ical.5 terminated with code 0 (NO_ERROR)
                2024-10-21 21:59:20.539  - info: dwd.0 (27090) starting. Version 2.8.5 in /opt/iobroker/node_modules/iobroker.dwd, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:59:22.261  - info: esphome.0 (27153) Try to connect to 192.168.178.91
                2024-10-21 21:59:22.317  - info: esphome.0 (27153) Native Integration of ESPHome Dashboard enabled
                2024-10-21 21:59:24.274  - info: host.ioB-Prod-Testsystem iobroker npm-rebuild: Rebuilding native modules ...
                2024-10-21 21:59:24.320  - info: ws.0 (27177) starting. Version 2.6.2 in /opt/iobroker/node_modules/iobroker.ws, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:59:24.519  - info: ws.0 (27177) socket.io server listening on port 8084
                2024-10-21 21:59:24.711  - info: fully-tablet-control.0 (27184) starting. Version 0.3.8 in /opt/iobroker/node_modules/iobroker.fully-tablet-control, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:59:25.003  - info: fullcalendar.0 (27210) starting. Version 2.4.5 in /opt/iobroker/node_modules/iobroker.fullcalendar, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:59:25.202  - info: trashschedule.0 (27101) starting. Version 3.3.0 in /opt/iobroker/node_modules/iobroker.trashschedule, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:59:25.455  - error: esphome.0 (27153) Client 192.168.178.91 unreachable !
                2024-10-21 21:59:25.998  - info: web.1 (27195) starting. Version 6.3.1 in /opt/iobroker/node_modules/iobroker.web, node: v22.10.0, js-controller: 7.0.1
                2024-10-21 21:59:27.343  - info: esphome.0 (27153) Bonjour service started, new  devices  will  be detected automatically
                2024-10-21 21:59:27.646  - info: web.1 (27195) http server listening on port 8089
                
                
                
                Feuersturm 1 Reply Last reply Reply Quote 0
                • Feuersturm
                  Feuersturm @Feuersturm last edited by

                  @foxriver76 nach einem erneuten iob stop und iob start gab es keine Fehler mehr im Log

                  foxriver76 1 Reply Last reply Reply Quote 0
                  • foxriver76
                    foxriver76 Developer @Feuersturm last edited by

                    @feuersturm hm jedenfalls komisch dass das UI Upgrade nicht geklappt hat, vorallem damit der Meldung dass Admin noch lief.

                    Diginix 1 Reply Last reply Reply Quote 0
                    • Diginix
                      Diginix @foxriver76 last edited by

                      @foxriver76 Bei mir hat das Update von 7.0.0 auf 7.0.1 über Admin webUI erfolgreich geklappt.

                      1 Reply Last reply Reply Quote 0
                      • Dr. Bakterius
                        Dr. Bakterius Most Active @foxriver76 last edited by

                        @foxriver76 Ich erhalte über GUI auch den Fehler SyntaxError: Unexpected token '<', "<!doctype "... is not valid JSON

                        Im Log steht dann:

                        2024-10-22 09:43:03.567 - error: host.iobroker [CONTROLLER_AUTO_UPGRADE] Uncaught Exception: Error: listen EADDRINUSE: address already in use :::8081
                        at Server.setupListenHandle [as _listen2] (node:net:1904:16)
                        at listenInCluster (node:net:1961:12)
                        at Server.listen (node:net:2063:7)
                        at UpgradeManager.startInsecureWebServer (file:///opt/iobroker/node_modules/iobroker.js-controller/src/lib/upgradeManager.ts:266:21)
                        at UpgradeManager.startWebServer (file:///opt/iobroker/node_modules/iobroker.js-controller/src/lib/upgradeManager.ts:198:18)
                        at main (file:///opt/iobroker/node_modules/iobroker.js-controller/src/lib/upgradeManager.ts:400:20)
                        

                        Ich habe es 2x versucht. Admin v7.1.5.

                        foxriver76 1 Reply Last reply Reply Quote 0
                        • foxriver76
                          foxriver76 Developer @Dr. Bakterius last edited by foxriver76

                          @dr-bakterius Okay, es scheint wohl eine Änderung im Fixer sowie Installer gegeben zu haben die das UI Upgrade zerstört. Also je nachdem wann zuletzt der Fixer ausgeführt wurde geht es nicht. Ingo bereitet einen Fix vor.

                          Feuersturm 1 Reply Last reply Reply Quote 1
                          • Feuersturm
                            Feuersturm @foxriver76 last edited by

                            @foxriver76 ich hab den fixer kurz vorher ausprobiert um den neuen Stand zu testen bzgl. root, multiuser.target etc.

                            Dann warte ich Mal auf eine neue Version

                            foxriver76 1 Reply Last reply Reply Quote 0
                            • foxriver76
                              foxriver76 Developer @Feuersturm last edited by

                              @feuersturm Fixer ist aktualisiert, bei mir läuft es wieder nach Ausführen des neuen Fixers

                              Dr. Bakterius 1 Reply Last reply Reply Quote 0
                              • Dr. Bakterius
                                Dr. Bakterius Most Active @foxriver76 last edited by

                                @foxriver76 Ja, nach dem Start des aktuellen Fixers funktioniert das Update. Danke!

                                1 Reply Last reply Reply Quote 0
                                • D
                                  DLehmann @foxriver76 last edited by

                                  @foxriver76

                                  Leider noch nicht. Der Fehler sieht jetzt aber anders aus. Eine Umstellung erfolgt aber nicht. iobroker ist gestoppt und der neue iob fix lief auch erfolgreich drüber.

                                  dirk@iobroker:~$ iob setup custom
                                  Current configuration:
                                  - Objects database:
                                    - Type: jsonl
                                    - Host/Unix Socket: 127.0.0.1
                                    - Port: 9001
                                  - States database:
                                    - Type: jsonl
                                    - Host/Unix Socket: 127.0.0.1
                                    - Port: 9000
                                  - Data Directory: ../../iobroker-data/
                                  
                                  Type of objects DB [(j)sonl, (f)ile, (r)edis, ...], default [jsonl]: r
                                  
                                  When Objects and Files are stored in a Redis database please consider the following:
                                  1. All data will be stored in RAM, make sure to have enough free RAM available!
                                  2. Make sure to check Redis persistence options to make sure a Redis problem will not cause data loss!
                                  3. The Redis persistence files can get big, make sure not to use an SD card to store them.
                                  
                                  Host / Unix Socket of objects DB(redis), default[127.0.0.1]: 
                                  Port of objects DB(redis), default[6379]: 
                                  Do you use a TLS connection for your "objects" redis-server? [y/N]:
                                  Type of states DB [(j)sonl, (f)file, (r)edis, ...], default [redis]: 
                                  Host / Unix Socket of states DB (redis), default[127.0.0.1]: 
                                  Port of states DB (redis), default[6379]: 
                                  Do you use a TLS connection for your "states" redis-server? [y/N]:
                                  Host name of this machine [iobroker]: 
                                  Please choose if this is a Master/single host (enter "m") or a Slave host (enter "S") you are about to edit. For Slave hosts the data migration will be skipped. [S/m]: m
                                  
                                  Important: Using redis for the Objects database is only supported
                                  with js-controller 2.0 or higher!
                                  When your system consists of multiple hosts please make sure to have
                                  js-controller 2.0 or higher installed on ALL hosts *before* continuing!
                                  
                                  
                                  Important #2: If you already did the migration on an other host
                                  please *do not* migrate again! This can destroy your system!
                                  
                                  
                                  Important #3: The process will migrate all files that were officially
                                  uploaded into the ioBroker system. If you have manually copied files into
                                  iobroker-data/files/... into own directories then these files will NOT be
                                  migrated! Make sure all files are in adapter directories inside the files
                                  directory!
                                  
                                  
                                  Do you want to migrate objects and states from "jsonl/jsonl" to "redis/redis" [y/N]: y
                                  
                                  Migrating the objects database will overwrite all objects! Are you sure that this is not a slave host and you want to migrate the data? [y/N]: y
                                  
                                  Connecting to previous DB "jsonl/jsonl"...
                                  Creating backup ...
                                  This can take some time ... please be patient!
                                  host.iobroker 15138 objects saved
                                  host.iobroker 12349 states saved
                                  host.iobroker Validating backup ...
                                  host.iobroker The backup is valid!
                                  Backup created: /opt/iobroker/backups/2024_10_22-17_58_59_backupiobroker-migration.tar.gz
                                  updating conf/iobroker.json
                                  
                                  Connecting to new DB "redis/redis" (can take up to 20s) ...
                                   Cannot read system.config: null (OK when migrating or restoring)
                                  Restore backup ...
                                  This can take some time ... please be patient!
                                  host.iobroker Cannot find extracted file "/opt/iobroker/node_modules/iobroker.js-controller/tmp/backup/backup.json" or "/opt/iobroker/node_modules/iobroker.js-controller/tmp/backup/config.json"
                                  Error happened during restore. Exit-Code: 26
                                  
                                  restoring conf/iobroker.json
                                  
                                  D 1 Reply Last reply Reply Quote 0
                                  • Dr. Bakterius
                                    Dr. Bakterius Most Active last edited by

                                    Noch ein Issue?

                                    Siehe https://forum.iobroker.net/post/1212105 und folgende...

                                    foxriver76 1 Reply Last reply Reply Quote 0
                                    • foxriver76
                                      foxriver76 Developer @Dr. Bakterius last edited by foxriver76

                                      @dr-bakterius kann der controller nix tun aktuell da der update Prozess via systemd als Root laufen muss, vermute ich dass es daher kommt.

                                      Mach gerne mal ein issue für „irgendwann“

                                      Dr. Bakterius 1 Reply Last reply Reply Quote 0
                                      • Dr. Bakterius
                                        Dr. Bakterius Most Active @foxriver76 last edited by

                                        @foxriver76 Das bedeutet, dass nach jedem Contoller-Update ein iob fix notwendig ist? War das vor v7 auch schon so? Da muss man erst recht wieder auf die Console und den ioBroker stoppen. Wo ist dann der Nutzen für ein Update über die UI? 🤔

                                        foxriver76 1 Reply Last reply Reply Quote 0
                                        • foxriver76
                                          foxriver76 Developer @Dr. Bakterius last edited by foxriver76

                                          @dr-bakterius ja seit es UI update gibt es lief technisch immer als root! Das Problem war bislang nicht bekannt, ich konnte es allerdings gestern Abend etwas umständlich lösen. https://github.com/ioBroker/ioBroker.js-controller/pull/2950

                                          foxriver76 created this issue in ioBroker/ioBroker.js-controller

                                          closed [fix]: UI upgrade now runs as the same user as the js-controller #2950

                                          Diginix 1 Reply Last reply Reply Quote 1
                                          • Diginix
                                            Diginix @foxriver76 last edited by

                                            @foxriver76 Ich habe schon Monate kein iob fix gemacht und konnte von v6 auf v7 und mit UI von 7.0.0 auf 7.0.1. Da bleiben bei mir Fragen offen warum bei mit etwas funktioniert, was nicht funktionieren dürfte.

                                            foxriver76 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            460
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            backup beta dynamic notifications js-controller lucy test
                                            28
                                            146
                                            13858
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo