    NEWS

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    • Monatsrückblick - April 2025

    E3DC Hauskraftwerk steuern

    This topic has been deleted. Only users with topic management privileges can see it.
    • P
      psrelax @ArnoD last edited by

      @arnod
      Hier bitte.

      2024-11-09 12:57:00.566  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: *******************  Debug LOG Tibber Skript Version 1.2.5 *******************
      2024-11-09 12:57:27.067  - info: admin.0 (363) ==> Connected system.user.admin from ::ffff:192.168.2.164
      2024-11-09 12:58:00.696  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ************************************************************************************
      2024-11-09 12:58:00.696  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** timerIds = 
      2024-11-09 12:58:00.696  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** timerTarget = []
      2024-11-09 12:58:00.696  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** timerState = []
      2024-11-09 12:58:00.696  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** timerObjektID = []
      2024-11-09 12:58:00.696  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** minStrompreis_48h = 0.3012
      2024-11-09 12:58:00.696  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** batterieKapazitaet_kWh = 15
      2024-11-09 12:58:00.696  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** Batterie_SOC = 8
      2024-11-09 12:58:00.696  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** Power_Bat_W = 0
      2024-11-09 12:58:00.696  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** Power_Grid = 186
      2024-11-09 12:58:00.696  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** prognoseLadezeitBatterie = 2
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** reichweiteBatterie = 1:04 h / 1:04 h
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** batteriepreisAktiv = true
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** strompreisBatterie = 0.1057
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** bruttoPreisBatterie = 0.1057
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** Aktueller Preis Tibber = 0.3133
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** naechstePhasen[1].endLocale = undefined
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** naechstePhasen[1].startLocale = undefined
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** naechstePhasen[1].Type = undefined
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** naechstePhasen[0].endLocale = undefined
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** naechstePhasen[0].startLocale = undefined
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** naechstePhasen[0].Type = undefined
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** aktivePhase.endLocale = 10.11.2024, 00:00:00
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** aktivePhase.startLocale = 9.11.2024, 00:00:00
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** aktivePhase.Type = peak
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** Schwellwert Spitzenstrompreis = 0.2955
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** Schwellwert hoher Strompreis = 
      0.26	
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** Schwellwert niedriger Strompreis = 
      0.10	
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** schneeBedeckt = false
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** Prognose PV-Leistung heute = 8.158499999999998 kWh
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** Prognose PV-Leistung morgen = 8.0955 kWh
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** pvLeistungAusreichend = false
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** eAutoLaden = false
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** BatterieEntladenSperren = false
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** BatterieLaden = false
      2024-11-09 12:58:00.697  - info: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** Status = Aktuell Strompreis zu hoch, es wird nicht geladen (aktive Phase: peak)
      2024-11-09 12:58:00.697  - warn: javascript.0 (15617) script.js.E3DC_ChargeControl.Tibber: ** ProgrammAblauf = 27,1,18,18/3,19,22,32,31,19,3,30, 
      

      Mir ist auch aufgefallen, dass seit ich gestern ioBroker neu aufgesetzt habe, bei Tibber im Jason für den morgigen Preis noch nichts stehen habe. Das kommt wahrscheinlich erst um ca. 14 Uhr wenn die neuen Preise veröffentlicht werden.
      Macht das evtl. auch ein Problem?

      A 1 Reply Last reply Reply Quote 0
      • A
        ArnoD @psrelax last edited by

        @psrelax sagte in E3DC Hauskraftwerk steuern:

        Das kommt wahrscheinlich erst um ca. 14 Uhr wenn die neuen Preise veröffentlicht werden.
        Macht das evtl. auch ein Problem?

        Nein, das ist eigentlich schon immer so.
        Hast du aktuell einen Tibberpreis unter 0,2955 € ? oder sind jetzt alle darüber ?

        P 1 Reply Last reply Reply Quote 0
        • P
          psrelax @ArnoD last edited by

          @arnod
          17352c9d-db7e-4be6-ac21-cb4d57e18c73-image.png

          1 Reply Last reply Reply Quote 0
          • A
            ArnoD last edited by ArnoD

            @psrelax
            Ok dann ist es klar, dass keine anderen Phasen erkannt werden, da alle Preise über 0,2955 € sind.
            Nur für mein Verständnis, was wäre in der Situation deine Erwartung, wann geladen und endladen wird ?

            P 1 Reply Last reply Reply Quote 0
            • azzkikrboy
              azzkikrboy last edited by

              Hallo @ArnoD ,

              seit einiger Zeit sehe ich jeden Morgen kurz nach 4 Uhr diese Warning im LOG und zwar immer 5 mal.

              Error in der function InterrogateSolcast. Fehler = Error: Error fetching data: Request failed with status code 429
              

              Um 4.03h wird zum ersten Mal Solcast Dach1 und Dach2 abgefragt (erfolgreich), dann nochmal um 4.05h (erfolgreich), dann nochmal um 4.07h (erfolgreich).
              Dann kommen die Fehler: 4.13h und 4.33h, 4.34h und 4.41h, 4.42h

              Das sollte aber nicht das Limit von 10 Abfragen pro Tag sprengen, oder? Hat sich da etwas im script 1.5.10 geändert?
              Vorher hatte ich diese Meldung nicht.

              A 1 Reply Last reply Reply Quote 0
              • A
                ArnoD @azzkikrboy last edited by

                @azzkikrboy
                Die Fehlernummer 429 sagt aus, dass zu viele Anfragen in einer zu kurzen Zeit an den Server gestellt wurden oder die Anzahl der zulässigen Anfragen überschritten ist.
                Kann sein das da Solcast was geändert hat vom Script ist das nicht abhängig.

                Warum willst du überhaupt so oft die Werte abfragen, da ändert sich doch nichts in so kurzer Zeit und vor 4:42 Uhr ist es auch völlig egal.

                azzkikrboy 1 Reply Last reply Reply Quote 0
                • P
                  psrelax @ArnoD last edited by

                  @arnod sagte in E3DC Hauskraftwerk steuern:

                  Nur für mein Verständnis, was wäre in der Situation deine Erwartung, wann geladen und endladen wird ?

                  Dann sollte jetzt doch alles in Ordnung sein mit meiner Umgebung!?

                  Generell würde ich sagen, dass es schon gut funktioniert. Heute würde ich gar nichts laden, da der Preis relativ geradlinig ist.
                  Allerdings habe ich weiter oben geschrieben, dass mein Speicher zu früh leer wird, da die Ladung zu früh abschaltet und dann nach dem Peak zu wenig Speicher übrig ist. Es müsste entweder mehr geladen werden oder die Entladung danach bis zum Anfang des Peaks gesperrt werden.
                  In meinem Post vor ca. 20 Stunden war das Problem, dass fast den ganzen Tag eine Entladesperre gesetzt war. Konnte mir das nicht erklären.

                  Du hast ja letztens noch ein paar Änderungen gemacht. Ich muss das nochmal anschauen, wie die Auswirkung jetzt ist.

                  P 1 Reply Last reply Reply Quote 0
                  • azzkikrboy
                    azzkikrboy @ArnoD last edited by azzkikrboy

                    @arnod sagte in E3DC Hauskraftwerk steuern:

                    @azzkikrboy
                    Die Fehlernummer 429 sagt aus, dass zu viele Anfragen in einer zu kurzen Zeit an den Server gestellt wurden oder die Anzahl der zulässigen Anfragen überschritten ist.
                    Kann sein das da Solcast was geändert hat vom Script ist das nicht abhängig.

                    Warum willst du überhaupt so oft die Werte abfragen, da ändert sich doch nichts in so kurzer Zeit und vor 4:42 Uhr ist es auch völlig egal.

                    Ähm, ich frage die Werte nicht ab, sondern dein Script ... das sind Fehlermeldungen von Charge_Control ...

                    azzkikrboy 1 Reply Last reply Reply Quote 0
                    • azzkikrboy
                      azzkikrboy @azzkikrboy last edited by

                      Hier mal das komplette Log.

                      2024-11-09 04:42:00.662	warn	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":"-==== Error in der function InterrogateSolcast. Fehler = Error: Error fetching data: Request failed with status code 429 ====-"}##
                      
                      javascript.0
                      2024-11-09 04:42:00.382	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" ****************************** Es wird Solcast Dach 1 abgerufen ****************************** "}##
                      
                      javascript.0
                      2024-11-09 04:42:00.381	warn	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":"-==== Error in der function InterrogateSolcast. Fehler = Error: Error fetching data: Request failed with status code 429 ====-"}##
                      
                      javascript.0
                      2024-11-09 04:42:00.015	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" ****************************** Es wird Solcast Dach 2 abgerufen ****************************** "}##
                      
                      javascript.0
                      2024-11-09 04:41:01.323	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Bewölkungsgrad 15 Uhr Proplanta 87.5"}##
                      
                      javascript.0
                      2024-11-09 04:41:01.323	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Bewölkungsgrad 12 Uhr Proplanta 100"}##
                      
                      javascript.0
                      2024-11-09 04:41:01.272	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Ueberschuss in Prozent = 0"}##
                      
                      javascript.0
                      2024-11-09 04:41:01.272	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Ueberschuss in kWh 0 = (Prognose kWh 23.7068 - Berechneter Eigenverbrauch 25) - FreieKapBatterie_kWh 9.9"}##
                      
                      javascript.0
                      2024-11-09 04:41:01.272	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" AktSpeicherSoC in % = 10"}##
                      
                      javascript.0
                      2024-11-09 04:41:01.271	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Eigenverbrauch Tag = 25"}##
                      
                      javascript.0
                      2024-11-09 04:41:01.209	warn	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":"-==== Error in der function InterrogateSolcast. Fehler = Error: Error fetching data: Request failed with status code 429 ====-"}##
                      
                      javascript.0
                      2024-11-09 04:41:00.912	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" ****************************** Es wird Solcast Dach 1 abgerufen ****************************** "}##
                      
                      javascript.0
                      2024-11-09 04:41:00.912	warn	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":"-==== Error in der function InterrogateSolcast. Fehler = Error: Error fetching data: Request failed with status code 429 ====-"}##
                      
                      javascript.0
                      2024-11-09 04:41:00.014	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" ****************************** Es wird Solcast Dach 2 abgerufen ****************************** "}##
                      
                      javascript.0
                      2024-11-09 04:34:00.971	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Bewölkungsgrad 15 Uhr Proplanta 87.5"}##
                      
                      javascript.0
                      2024-11-09 04:34:00.970	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Bewölkungsgrad 12 Uhr Proplanta 100"}##
                      
                      javascript.0
                      2024-11-09 04:34:00.923	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Ueberschuss in Prozent = 0"}##
                      
                      javascript.0
                      2024-11-09 04:34:00.923	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Ueberschuss in kWh 0 = (Prognose kWh 23.7068 - Berechneter Eigenverbrauch 25) - FreieKapBatterie_kWh 9.9"}##
                      
                      javascript.0
                      2024-11-09 04:34:00.923	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" AktSpeicherSoC in % = 10"}##
                      
                      javascript.0
                      2024-11-09 04:34:00.922	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Eigenverbrauch Tag = 25"}##
                      
                      javascript.0
                      2024-11-09 04:34:00.862	warn	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":"-==== Error in der function InterrogateSolcast. Fehler = Error: Error fetching data: Request failed with status code 429 ====-"}##
                      
                      javascript.0
                      2024-11-09 04:34:00.334	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" ****************************** Es wird Solcast Dach 1 abgerufen ****************************** "}##
                      
                      javascript.0
                      2024-11-09 04:34:00.333	warn	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":"-==== Error in der function InterrogateSolcast. Fehler = Error: Error fetching data: Request failed with status code 429 ====-"}##
                      
                      javascript.0
                      2024-11-09 04:34:00.009	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" ****************************** Es wird Solcast Dach 2 abgerufen ****************************** "}##
                      
                      javascript.0
                      2024-11-09 04:33:01.248	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Bewölkungsgrad 15 Uhr Proplanta 87.5"}##
                      
                      javascript.0
                      2024-11-09 04:33:01.248	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Bewölkungsgrad 12 Uhr Proplanta 100"}##
                      
                      javascript.0
                      2024-11-09 04:33:01.196	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Ueberschuss in Prozent = 0"}##
                      
                      javascript.0
                      2024-11-09 04:33:01.195	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Ueberschuss in kWh 0 = (Prognose kWh 23.7068 - Berechneter Eigenverbrauch 25) - FreieKapBatterie_kWh 9.9"}##
                      
                      javascript.0
                      2024-11-09 04:33:01.195	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" AktSpeicherSoC in % = 10"}##
                      
                      javascript.0
                      2024-11-09 04:33:01.195	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Eigenverbrauch Tag = 25"}##
                      
                      javascript.0
                      2024-11-09 04:33:01.138	warn	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":"-==== Error in der function InterrogateSolcast. Fehler = Error: Error fetching data: Request failed with status code 429 ====-"}##
                      
                      javascript.0
                      2024-11-09 04:33:00.610	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" ****************************** Es wird Solcast Dach 1 abgerufen ****************************** "}##
                      
                      javascript.0
                      2024-11-09 04:33:00.610	warn	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":"-==== Error in der function InterrogateSolcast. Fehler = Error: Error fetching data: Request failed with status code 429 ====-"}##
                      
                      javascript.0
                      2024-11-09 04:33:00.007	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" ****************************** Es wird Solcast Dach 2 abgerufen ****************************** "}##
                      
                      javascript.0
                      2024-11-09 04:13:01.160	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Bewölkungsgrad 15 Uhr Proplanta 87.5"}##
                      
                      javascript.0
                      2024-11-09 04:13:01.159	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Bewölkungsgrad 12 Uhr Proplanta 100"}##
                      
                      javascript.0
                      2024-11-09 04:13:01.111	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Ueberschuss in Prozent = 0"}##
                      
                      javascript.0
                      2024-11-09 04:13:01.110	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Ueberschuss in kWh 0 = (Prognose kWh 23.7068 - Berechneter Eigenverbrauch 25) - FreieKapBatterie_kWh 9.9"}##
                      
                      javascript.0
                      2024-11-09 04:13:01.110	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" AktSpeicherSoC in % = 10"}##
                      
                      javascript.0
                      2024-11-09 04:13:01.110	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Eigenverbrauch Tag = 25"}##
                      
                      javascript.0
                      2024-11-09 04:13:01.009	warn	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":"-==== Error in der function InterrogateSolcast. Fehler = Error: Error fetching data: Request failed with status code 429 ====-"}##
                      
                      javascript.0
                      2024-11-09 04:13:00.728	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" ****************************** Es wird Solcast Dach 1 abgerufen ****************************** "}##
                      
                      javascript.0
                      2024-11-09 04:13:00.728	warn	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":"-==== Error in der function InterrogateSolcast. Fehler = Error: Error fetching data: Request failed with status code 429 ====-"}##
                      
                      javascript.0
                      2024-11-09 04:13:00.010	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" ****************************** Es wird Solcast Dach 2 abgerufen ****************************** "}##
                      
                      javascript.0
                      2024-11-09 04:07:02.688	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Bewölkungsgrad 15 Uhr Proplanta 87.5"}##
                      
                      javascript.0
                      2024-11-09 04:07:02.687	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Bewölkungsgrad 12 Uhr Proplanta 100"}##
                      
                      javascript.0
                      2024-11-09 04:07:02.639	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Ueberschuss in Prozent = 0"}##
                      
                      javascript.0
                      2024-11-09 04:07:02.639	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Ueberschuss in kWh 0 = (Prognose kWh 23.7068 - Berechneter Eigenverbrauch 25) - FreieKapBatterie_kWh 9.79"}##
                      
                      javascript.0
                      2024-11-09 04:07:02.639	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" AktSpeicherSoC in % = 11"}##
                      
                      javascript.0
                      2024-11-09 04:07:02.638	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Eigenverbrauch Tag = 25"}##
                      
                      javascript.0
                      2024-11-09 04:07:02.586	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Summe PV Leistung Tag 2024-11-15 pv_estimate= 18.83 pv_estimate90= 28.42"}##
                      
                      javascript.0
                      2024-11-09 04:07:02.583	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Summe PV Leistung Tag 2024-11-14 pv_estimate= 12.25 pv_estimate90= 29.35"}##
                      
                      javascript.0
                      2024-11-09 04:07:02.580	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Summe PV Leistung Tag 2024-11-13 pv_estimate= 17.76 pv_estimate90= 30.85"}##
                      
                      javascript.0
                      2024-11-09 04:07:02.575	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Summe PV Leistung Tag 2024-11-12 pv_estimate= 13.25 pv_estimate90= 25.11"}##
                      
                      javascript.0
                      2024-11-09 04:07:02.567	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Summe PV Leistung Tag 2024-11-11 pv_estimate= 15.87 pv_estimate90= 26.8"}##
                      
                      javascript.0
                      2024-11-09 04:07:02.559	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Summe PV Leistung Tag 2024-11-10 pv_estimate= 13 pv_estimate90= 26.69"}##
                      
                      javascript.0
                      2024-11-09 04:07:02.549	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Summe PV Leistung Tag 2024-11-09 pv_estimate= 24.44 pv_estimate90= 29.8"}##
                      
                      javascript.0
                      2024-11-09 04:07:02.548	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Rueckmeldung response.status Solcast= 200"}##
                      
                      javascript.0
                      2024-11-09 04:07:01.767	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" ****************************** Es wird Solcast Dach 1 abgerufen ****************************** "}##
                      
                      javascript.0
                      2024-11-09 04:07:01.765	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" Rueckmeldung response.status Solcast= 200"}##
                      
                      javascript.0
                      2024-11-09 04:07:00.014	info	script.js.Charge_Control_1_5_10: ##{"from":"Charge-Control", "message":" ****************************** Es wird Solcast Dach 2 abgerufen ****************************** "}##
                      
                      A 1 Reply Last reply Reply Quote 0
                      • P
                        psrelax @psrelax last edited by psrelax

                        @ArnoD
                        Was ich jetzt aktuell nicht verstehe ist:
                        Schwellwert hoher Preis=0,26 -> Batterie wird nicht geladen
                        Schwellwert hoher Preis=0,50 -> Batterie wird geladen

                        1654dfd5-9562-4db8-babe-72f2dd2b7170-image.png
                        e0873c4b-0926-490b-9eab-e5673ce84939-image.png
                        Der Unterschied zwischen Spitzenstrompreis und niedrigstem Strompreis ist doch viel zu gering, um den Batteriepreis zu übersteigen.

                        A 1 Reply Last reply Reply Quote 0
                        • A
                          ArnoD @azzkikrboy last edited by

                          @azzkikrboy
                          Dann stimmt bei dir was nicht, das Script ruft nur einmal zwischen 4:00 Uhr und 5:00 Uhr die Daten ab.
                          Entweder laufen bei dir zwei Instanzen oder es wurde etwas nicht sauber beendet.
                          Du kannst mal versuchen, den Javascript Adapter zu stoppen und wieder zu starten und dann prüfen ob es wieder funktioniert.

                          1 Reply Last reply Reply Quote 0
                          • A
                            ArnoD @psrelax last edited by ArnoD

                            @psrelax

                            Der Unterschied zwischen Spitzenstrompreis und niedrigstem Strompreis ist doch viel zu gering, um den Batteriepreis zu übersteigen.

                            Kann dir hier nicht ganz folgen 🙂
                            Der Batteriepreis ist bei dir 0,1057 € bedeutet, dass die Entladesperre deaktiviert wird, sobald der Tibberpreis höher ist. Das hat erstmal nichts mit dem Schwellwert zu tun.

                            Dann Einstellung Schwellwert hoher Strompreis bei 0,26 € bedeutet, wenn Tibber Preis darüber ist, hohe Preisphase, es wird nur geladen um eine Spitzenstrompreisphase (Peak) zu überbrücken, ansonsten wird nicht geladen.
                            Wenn der Tibber Preis aber über Schwellwert hoher Strompreis plus Ladeverluste ist = 0,2955 dann ist gerade eine Spitzenstrompreisphase (Peak) und es wird gar nicht mehr geladen, solange diese andauert, sondern entladen, außer dein Batteriepreis wäre noch höher, dann wird auch da nicht entladen.

                            Das ist der Grund, warum bei der Einstellung Schwellwert hoher Strompreis bei 0,26 € nicht geladen wird.

                            Dann Einstellung Schwellwert hoher Strompreis bei 0,50 € bedeutet, wenn Tibber Preis darunter ist, normale Preisphase, es wird der günstigste Preis gesucht und die Batterie bis auf eingestellten max. SOC geladen. Wenn während dem Laden durch die Verlängerung der Batteriereichweite ein günstigerer Preis gefunden wird, wird das Laden abgebrochen und gewartet bis diese Preisphase erreicht wird, um dann da zu laden. Entladen wird hier nur, wenn der Tibber Preis über Schwellwert hoher Strompreis ist und der Batteriepreis kleiner aktueller Tibber Preis ist.

                            Deswegen wird bei Einstellung Schwellwert hoher Strompreis bei 0,50 € geladen.

                            Die Frage ist halt was du bei dem Tibber Diagramm erreichen willst. Wenn du willst das z.B um 7:00 Uhr geladen wird um dann ab 16:00 Uhr zu entladen musst du den Schwellwert hoher Strompreis auf 0,31 € einstellen.

                            Wenn du aber der Meinung bist der Strompreis ist dir schon zu hoch um überhaupt zu laden, dann kannst du den
                            den Schwellwert hoher Strompreis auf 0,26 € einstellen und nur noch bei diesem Preis Laden.

                            Um aber zu verstehen wie du dir die Regelung vorstellst müsstest du mir ein Bild vom Tibber Diagramm schicken und mir sagen wann du gerne laden und wann entladen würdest.
                            Es gibt auch die Möglichkeit die Schwellwerte automatisch nach dem günstigsten Strompreis innerhalb 48 h zu setzen und somit das ganze dynamisch zu gestalten. Hat halt dann den Nachteil das man es nicht mehr selber im Griff hat bis zu welchem Strompreis man seine Batterie noch verwenden will um aus dem Netz zu laden.

                            1 Reply Last reply Reply Quote 0
                            • A
                              ArnoD last edited by

                              Ich mache mir mal Gedanken über eine automatische Anpassung vom Schwellwert, ich denke, das ist eventuell weniger verwirrend und man muss keine Einstellungen anpassen.
                              Das ganze werde ich zum an und abwählen ausführen, sodass man es sich selber noch aussuchen kann, was einem lieber ist. 🙂

                              1 Reply Last reply Reply Quote 1
                              • A
                                ArnoD last edited by

                                Tibber Skript,
                                Version: 1.3.0 auf Github hochgeladen.

                                Änderungen:

                                • neue Anwahl für automatische Preisanpassung in der View hinzugefügt
                                • Aktueller Batteriepreis wird wieder in der View angezeigt.
                                • Die Schwellwerte werden bei Anwahl autom. Preisanpassung jetzt dynamisch nach dem günstigsten Tibber Preis innerhalb 48 bzw. 24 Stunden gesetzt. (Testphase 🙂 )
                                • Neue Objekt ID "automPreisanpassung"
                                • Fehler behoben, dass noch mal nachgeladen wurde, wenn der Batterie SOC um 1% abgefallen ist. Das führte zu ständigem ein und ausschalten der Batterieladung.
                                P 1 Reply Last reply Reply Quote 1
                                • P
                                  psrelax @ArnoD last edited by

                                  @arnod
                                  Bis jetzt schaut es sehr gut aus.
                                  Heute war eine blöde Konstellation der Spitzen. Sag mir mal bitte, ob hier theoretisch geladen hätte werden müssen. Ich meine ja, zwischen den beiden Bergen.
                                  Wenn du noch Logs brauchst, gib mir bescheid.
                                  117dbe68-718a-4f20-93a3-eac0cfbc0e09-image.png

                                  A 1 Reply Last reply Reply Quote 0
                                  • A
                                    ArnoD @psrelax last edited by

                                    @psrelax
                                    Da ist bereits der Preis zu hoch um zu laden, wenn dann hätte vorher von 0:00 Uhr bis 4:00 Uhr die Batterie noch geladen werden müssen.
                                    Von 2:00 Uhr bis 3:00 Uhr wurde ja auch geladen, die Frage ist halt, ob die eingestellten 80 % erreicht wurden und wenn ja, ob man den Soll SOC nicht auf 90 % oder 100 % einstellen sollte, wenn man weis das eher nicht mit Sonne zu rechnen ist.
                                    Es wird aber immer solche Situationen geben, wo man sich überlegt, ob es nicht besser wäre da noch mal zu laden.
                                    Wenn man es sich aber mal ausrechnet, was man dann gespart hätte, ist das eher zu vernachlässigen.

                                    Wenn ich mal davon ausgehe, dass du einen Stromverbrauch von 1000W hast, dann würde in der Situation folgende Berechnung zutreffen.

                                    Kosten Laden von 12:00 Uhr - 13:00 Uhr 10 kWh Laden = 5 kWh *0,3784 = 1,892 € + 5 kWh * 0,3723 = 3,7535 €

                                    Kosten ohne laden von 12:00 - 22:00 Uhr 0,3784+0,3723+0,3936+0,4465+0,5107+,05644+0,4543+0,39+0,363+0,3431+0,3237 = 4,54 €

                                    Somit reden wir in dem Fall von 4,54 - 3,75 = 0,79 € Ersparnis, wenn man da geladen hätte.

                                    P 1 Reply Last reply Reply Quote 0
                                    • P
                                      psrelax @ArnoD last edited by

                                      @arnod
                                      Hast Recht, der SOC war bereits bei 80%. Ich hab ihn jetzt auf 99% gestellt.

                                      1 Reply Last reply Reply Quote 0
                                      • A
                                        ArnoD last edited by

                                        Tibber Skript,
                                        Version: 1.3.1 auf Github hochgeladen.

                                        Änderungen:

                                        • kleinere Optimierungen bei der automatischen Preisanpassung.
                                        1 Reply Last reply Reply Quote 1
                                        • A
                                          ArnoD last edited by

                                          Tibber Skript,
                                          Version: 1.3.2 auf Github hochgeladen.

                                          Änderungen:

                                          • kleinere Fehler behoben und code aufgeräumt
                                          M 1 Reply Last reply Reply Quote 1
                                          • M
                                            Modulo-N @ArnoD last edited by Modulo-N

                                            @arnod : Hallo Arno...
                                            Ich bekomme leider mehrmals am Tag diese Fehlermeldungen en masse (jeweils einmal pro Minute im Doppelpack):

                                            javascript.0 20:10:53.850 error script.js.E3DC-Control.Tibber-1_3_2: Fehler in Funktion bestLoadTime: Cannot read properties of undefined (reading 'total')
                                            javascript.0 20:10:53.852 error script.js.E3DC-Control.Tibber-1_3_2: Fehler in Funktion tibberSteuerungHauskraftwerk: Cannot read properties of undefined (reading 'getTime')

                                            Der zweite scheint ein "Folgefehler" zu sein, aber der erste sieht komisch aus...

                                            Ich glaube es liegt an der Zeile
                                            blockPreis += entry.total;
                                            denn dort ist der einzige Abruf von .total in der Funktion...

                                            Vielleicht in index-Fehler?

                                            Ich konnte den Fehler quick&dirty mit
                                            if (entry != null) blockPreis += entry.total
                                            also einer Prüfung auf Definiertheit von entry unterdrücken und siehe da, auch der Folgefehler ist weg. Das ist aber nur Rumdoktern an den Symptomen, die Ursache für den Fehler habe ich nicht finden können, muss aber irgendwie am Preis-Array liegen...

                                            A 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            785
                                            Online

                                            31.7k
                                            Users

                                            79.8k
                                            Topics

                                            1.3m
                                            Posts

                                            70
                                            3331
                                            1363178
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo