    This topic has been deleted. Only users with topic management privileges can see it.
    • Thomas Braun
      Thomas Braun Most Active @HomeSweetHome last edited by

      @homesweethome

      Kann man auch (zu einem gewissen Grad).
      Aber
      1234567812345678
      ist keine zufällige Hex-Zahl.
      Das sähe so aus:

      a611156d574d27ce
      4a3ae8de644cd481
      688b94882b4e64d1
      3ea66f995365e55d
      7e4548fcc028c5d8
      

      Sei doch was kreativer...

      Ich vermute aber auch eher, dass du da den falschen/unvollständigen Link 'by-id' drin hast und das Geräte wird gar nicht angesprochen. Mein Geräte-Link ist viel länger. Ist aber auch ein anderer Stick.

      1 Reply Last reply Reply Quote 0
      • haus-automatisierung
        haus-automatisierung Developer Most Active @HomeSweetHome last edited by

        @homesweethome sagte in SONOFF Stick unter ioBroker-VM-Proxmox:

        ja, die ganze Länge...

        Sorry, ich bin hier raus... ist ja schon klar dass es mit der kurzen Angabe dann nicht klappt.

        H 1 Reply Last reply Reply Quote 0
        • H
          HomeSweetHome @haus-automatisierung last edited by HomeSweetHome

          @haus-automatisierung

          Sorry dass ich euch hier ein wenig verwirre. Hatte die gekürze Versionen gesendet, da ich der Meinung war nicht alle "persönlichen/unique" Daten im Forum zu senden

          Aber mit /dev/serial/by-id/usb-Itead_Sonoff_Zigbee_3.0_USB_Dongle_Plus_V2_1c72f71ac814ef11831c6fb8bf9df066-if00-port0 geht es auch nicht

          ls /dev/serial/by-id
          usb-Itead_Sonoff_Zigbee_3.0_USB_Dongle_Plus_V2_1c72f71ac814ef11831c6fb8bf9df066-if00-port0

          Thomas Braun 1 Reply Last reply Reply Quote 0
          • Thomas Braun
            Thomas Braun Most Active @HomeSweetHome last edited by

            @homesweethome

            In

            iob diag
            

            steht der Link auch drin. Fertig zum kopieren und einfügen.
            Schau dir das an, kürz da aber natürlich NICHTS raus. Wie soll man denn mit unvollständigen Infos da irgendwie helfen?

            H 1 Reply Last reply Reply Quote 0
            • H
              HomeSweetHome @Thomas Braun last edited by

              @thomas-braun Ja, da tauch der Link auch auf

              /dev/serial/by-id/usb-Itead_Sonoff_Zigbee_3.0_USB_Dongle_Plus_V2_1c72f71ac814ef11831c6fb8bf9df066-if00-port0

              reinkopiert - geht trotzdem mit einer zufälligen PAN-Id nicht 😞

              Thomas Braun Asgothian 3 Replies Last reply Reply Quote 0
              • Thomas Braun
                Thomas Braun Most Active @HomeSweetHome last edited by

                @homesweethome

                Zeig mal das log dazu.
                Oder die vollständige Ausgabe von

                iob diag
                
                1 Reply Last reply Reply Quote 0
                • Thomas Braun
                  Thomas Braun Most Active @HomeSweetHome last edited by

                  @homesweethome

                  Zu den PAN-IDs usw:

                  https://forum.iobroker.net/topic/78452/sonoff-zigbee-will-einfach-nicht/4?_=1733490531030

                  1 Reply Last reply Reply Quote 0
                  • Asgothian
                    Asgothian Developer @HomeSweetHome last edited by

                    @homesweethome

                    Zeig bitte ein vollständiges log eines Start Versuchs des zigbee Adapters. Das was du weiter oben gepostet hast ist so kurz das es keine Informationen enthält.

                    Im Zweifelsfall

                    • zigbee adapter anhalten
                    • sicherstellen das kein zigbee Prozess mehr läuft (alternativ - 30 s warten)
                    • log löschen
                    • zigbee Adapter starten
                    • 20 sekunden warten
                    • log herunterladen - alle Zeilen die nicht vom Host, dem Zigbee Adapter oder dem JSController stammen entfernen
                    • log hier in code Tags posten.

                    A.

                    H 1 Reply Last reply Reply Quote 0
                    • H
                      HomeSweetHome @Asgothian last edited by HomeSweetHome

                      @asgothian , anbei der letzte Teil von iob diag. Davor scheint es keine Auffälligkeiten zu geben

                      USB-Devices by-id:
                      USB-Sticks -  Avoid direct links to /dev/tty* in your adapter setups, please always prefer the links 'by-id':
                      
                      /dev/serial/by-id/usb-Itead_Sonoff_Zigbee_3.0_USB_Dongle_Plus_V2_1c72f71ac814ef11831c6fb8bf9df066-if00-port0
                      
                      Your zigbee.0 COM-Port is matching 'by-id'. Very good!
                      
                      Adapter State
                      + system.adapter.zigbee.0                 : zigbee                : ioBroker                                 -  enabled, port: /dev/serial/by-id/usb-Itead_Sonoff_Zigbee_3.0_USB_Dongle_Plus_V2_1c72f71ac814ef11831c6fb8bf9df066-if00-port0
                      
                      + instance is alive
                      
                      Enabled adapters with bindings
                      + system.adapter.zigbee.0                 : zigbee                : ioBroker                                 -  enabled, port: /dev/serial/by-id/usb-Itead_Sonoff_Zigbee_3.0_USB_Dongle_Plus_V2_1c72f71ac814ef11831c6fb8bf9df066-if00-port0
                      
                      2024-12-06 21:37:19.605  - info: host.ioBroker stopInstance system.adapter.zigbee.0 (force=false, process=true)
                      2024-12-06 21:37:19.607  - info: zigbee.0 (31563) Got terminate signal TERMINATE_YOURSELF
                      2024-12-06 21:37:19.649  - info: host.ioBroker stopInstance system.adapter.zigbee.0 send kill signal
                      2024-12-06 21:37:19.811  - info: admin.0 (14867) <== Disconnect system.user.admin from ::ffff:192.168.178.101
                      2024-12-06 21:37:19.608  - info: zigbee.0 (31563) cleaned everything up...
                      2024-12-06 21:37:19.609  - info: zigbee.0 (31563) Zigbee: disabling joining new devices.
                      2024-12-06 21:37:20.045  - warn: zigbee.0 (31563) Failed to stop zigbee during startup
                      2024-12-06 21:37:20.045  - info: zigbee.0 (31563) terminating
                      2024-12-06 21:37:20.046  - info: zigbee.0 (31563) Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                      2024-12-06 21:37:20.108  - info: zigbee.0 (31563) terminating
                      2024-12-06 21:37:20.599  - info: host.ioBroker instance system.adapter.zigbee.0 terminated with code 11 (ADAPTER_REQUESTED_TERMINATION)
                      2024-12-06 21:37:23.722  - info: host.ioBroker instance system.adapter.zigbee.0 in version "1.10.3" started with pid 33917
                      2024-12-06 21:37:25.283  - info: zigbee.0 (33917) starting. Version 1.10.3 in /opt/iobroker/node_modules/iobroker.zigbee, node: v20.18.0, js-controller: 7.0.3
                      2024-12-06 21:37:25.311  - info: zigbee.0 (33917) delete old Backup files. keep only last 10
                      2024-12-06 21:37:25.311  - info: zigbee.0 (33917) Starting Zigbee  npm ...
                      2024-12-06 21:37:25.512  - info: zigbee.0 (33917) Installed Version: iobroker.zigbee@1.10.3
                      2024-12-06 21:37:29.030  - error: zigbee.0 (33917) Starting zigbee-herdsman problem : "startup failed - configuration-adapter mismatch - see logs above for more information"
                      2024-12-06 21:37:29.031  - error: zigbee.0 (33917) Failed to start Zigbee
                      2024-12-06 21:37:29.031  - error: zigbee.0 (33917) Error herdsman start
                      2024-12-06 21:37:39.032  - info: zigbee.0 (33917) Try to reconnect. 1 attempts left
                      2024-12-06 21:37:39.032  - info: zigbee.0 (33917) Starting Zigbee  npm ...
                      2024-12-06 21:37:39.038  - info: zigbee.0 (33917) Installed Version: iobroker.zigbee@1.10.3
                      2024-12-06 21:38:09.193  - error: zigbee.0 (33917) Starting zigbee-herdsman problem : "Failure to connect"
                      2024-12-06 21:38:09.194  - error: zigbee.0 (33917) Failed to start Zigbee
                      2024-12-06 21:38:09.194  - error: zigbee.0 (33917) Error herdsman start
                      
                      Thomas Braun 1 Reply Last reply Reply Quote 0
                      • Thomas Braun
                        Thomas Braun Most Active @HomeSweetHome last edited by

                        @homesweethome sagte in SONOFF Stick unter ioBroker-VM-Proxmox:

                        Starting zigbee-herdsman problem : "startup failed - configuration-adapter mismatch - see logs above for more information"

                        Dann jetzt die Konfig übereinander bringen wie hier beschrieben:

                        https://forum.iobroker.net/topic/78452/sonoff-zigbee-will-einfach-nicht/4?_=1733490531030

                        1 Reply Last reply Reply Quote 0
                        • H
                          HomeSweetHome last edited by HomeSweetHome

                          @thomas-braun , kann ich die beiden Dateien einfach löschen - shepherd.db und nvbackup.json? Nachdem ich noch kein ZigBee Netzwerk am Laufen habe. Werden die Dateien mit den aktuellen Einstellungen neu generiert?

                          Asgothian 1 Reply Last reply Reply Quote 0
                          • Asgothian
                            Asgothian Developer @HomeSweetHome last edited by Asgothian

                            @homesweethome ja

                            wichtig - adapter vorher anhalten

                            A.

                            H 1 Reply Last reply Reply Quote 0
                            • H
                              HomeSweetHome @Asgothian last edited by HomeSweetHome

                              @asgothian, @Thomas Braun, @haus-automatisierung,

                              Adapter gestoppt - beide Dateien gelöscht - Adapter gestartet

                              e1e02c3d-8cf7-45dc-a05e-199d6051d109-grafik.png

                              Danke für eure Hilfe und eure Geduld für einen blutigen Linux/ioBroker Anfänger 👍

                              1 Reply Last reply Reply Quote 0
                              • First post
                                Last post

                              Support us

                              ioBroker
                              Community Adapters
                              Donate
                              FAQ Cloud / IOT
                              HowTo: Node.js-Update
                              HowTo: Backup/Restore
                              Downloads
                              BLOG

                              982
                              Online

                              31.6k
                              Users

                              79.4k
                              Topics

                              1.3m
                              Posts

                              5
                              34
                              994
                              Loading More Posts
                              • Oldest to Newest
                              • Newest to Oldest
                              • Most Votes
                              Reply
                              • Reply as topic
                              Log in to reply
                              Community
                              Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                              The ioBroker Community 2014-2023
                              logo