    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    • Monatsrückblick - April 2025

    source does not exist for "read" function

    This topic has been deleted. Only users with topic management privileges can see it.
    • Thomas Braun
      Thomas Braun Most Active last edited by

      Seit kurzem taucht im Log folgendes auf:

      2025-02-01 13:25:18.543  - error: javascript.0 (888) source in "alias.0.0_userdata.0.solix.solarbank_info.total_battery_power" does not exist for "read" function: "100*val"
      2025-02-01 13:25:18.543  - error: history.0 (857) source in "alias.0.0_userdata.0.solix.solarbank_info.total_battery_power" does not exist for "read" function: "100*val"
      

      Der genannte DP 'total_battery_power' wird im Alias Manager noch so 'behandelt':
      aac38441-5b71-430d-b5cf-8ab5c2b889d2-grafik.png

      Andere DP, die nicht noch mit 100 multipliziert werden müssen tauchen auf. Wie bekomme ich das wieder sauber hin?

      Homoran 1 Reply Last reply Reply Quote 0
      • Homoran
        Homoran Global Moderator Administrators @Thomas Braun last edited by

        @thomas-braun sagte in source does not exist for "read" function:

        source in "alias.0.0_userdata.0.solix.solarbank_info.total_battery_power" does not exist for "read

        wie sehen die Objektdaten des QuellDPs aus

        Thomas Braun 1 Reply Last reply Reply Quote 0
        • Thomas Braun
          Thomas Braun Most Active @Homoran last edited by Thomas Braun

          @homoran

          Da dürfte der Hase im Pfeffer liegen.
          Kommt als String ums Eck:

          {
            "common": {
              "name": "total_battery_power",
              "type": "string",
              "role": "value",
              "read": true,
              "write": true
            },
            "native": {},
            "type": "state",
            "from": "system.adapter.javascript.0",
            "user": "system.user.admin",
            "ts": 1738344042869,
            "_id": "0_userdata.0.solix.solarbank_info.total_battery_power",
            "acl": {
              "object": 1636,
              "state": 1636,
              "owner": "system.user.admin",
              "ownerGroup": "system.group.administrator"
            }
          }
          

          Offenbar hat sich da das Format so wie es aus der Batterie geliefert wird geändert. Ich muss das also dann noch irgendwo in der Kette auf Number umstellen. Ich weiß nur nicht wo und wie am besten. Im Alias-Adapter?

          1 Reply Last reply Reply Quote 0
          • mickym
            mickym Most Active last edited by mickym

            Na wenn da nur Zahlen rauskommen und Du schreibst ja schließlich mit irgendwas in 0_userdata.0 - dann würde ich halt mal die Quelle auf Zahl umstellen und prüfen mit was Du auch immer schreibst, dass Du Zahlen schreibst. Das was in 0_userdata.0 steht schreibst ja Du bzw. ein Skript da rein.

            Mir ist nicht bekannt, dass die "Batterie" oder irgendein Adapter direkt unter 0_userdata.0 schreibt.

            Thomas Braun 1 Reply Last reply Reply Quote 0
            • Thomas Braun
              Thomas Braun Most Active @mickym last edited by

              @mickym sagte in source does not exist for "read" function:

              Das was in 0_userdata.0 steht schreibst ja Du bzw. ein Skript da rein.

              Das kommt über mqtt da ungefiltert rein.

              mickym 1 Reply Last reply Reply Quote 0
              • mickym
                mickym Most Active @Thomas Braun last edited by mickym

                @thomas-braun Na auch wenn du dann wahrscheinlich mit dem mqtt-client arbeitest, müsstest Du doch den Typ selbst definieren können.

                Und für die Fehlerbehebung würde ich wenn nicht mit dem Adapter arbeiten, sondern direkt im Alias. Adapter sind immer Fehlerquellen.

                Thomas Braun 1 Reply Last reply Reply Quote 0
                • Thomas Braun
                  Thomas Braun Most Active @mickym last edited by

                  @mickym

                  Das ist ja genau die Frage. Wo in der Kette konvertiere ich den String am besten in ein Zahlenformat. 7
                  Die Batterie schickt ein json an mosquitto, der mqtt-client holt das dann in den ioBroker rein, das ganze wird in userdata.0 geschoben und dann mit dem Alias-Adapter verwurstet.

                  Wo setze ich da an?

                  mickym paul53 2 Replies Last reply Reply Quote 0
                  • mickym
                    mickym Most Active @Thomas Braun last edited by mickym

                    @thomas-braun In Mosquitto ist alles gut - der macht keine Konvertierung, sondern das ist ein Objekt. Dann ist es auch richtig, dass unter 0_userdata.0...Datenpunkt ein String ist, da das dann ein JSON ist. Das extrahieren der Zahl machst Du dann im Alias - aber ich würde es halt nicht im Adapter machen, sondern direkt im Alias.

                    Das heißt in deinem 0_userdata.0 Datenpunkt sollte eigentlich ein JSON String stehen. Poste den mal, dann können wir uns überlegen wie die Readfunktion im Alias auszusehen hat.

                    Normalerweise extrahiert man die Eigenschaft mit

                    (JSON.parse(val).Eigenschaft) * 100
                    
                    Thomas Braun 1 Reply Last reply Reply Quote 0
                    • Thomas Braun
                      Thomas Braun Most Active @mickym last edited by

                      @mickym

                      0_userdata.0.solix.solarbank_info.total_battery_power

                      Objekt schaut wohl so aus:

                      {
                        "common": {
                          "name": "total_battery_power",
                          "type": "string",
                          "role": "value",
                          "read": true,
                          "write": true
                        },
                        "native": {},
                        "type": "state",
                        "from": "system.adapter.javascript.0",
                        "user": "system.user.admin",
                        "ts": 1738344042869,
                        "_id": "0_userdata.0.solix.solarbank_info.total_battery_power",
                        "acl": {
                          "object": 1636,
                          "state": 1636,
                          "owner": "system.user.admin",
                          "ownerGroup": "system.group.administrator"
                        }
                      }
                      
                      mickym 1 Reply Last reply Reply Quote 0
                      • mickym
                        mickym Most Active @Thomas Braun last edited by mickym

                        @thomas-braun Nein das ist der Pfad oder die ID des Objektes. Geh mal bitte unter objekte und auf den Datenpunkt
                        solix.solarbank_info.total_battery_power unter 0_userdata.0 und dann kopiere mal den JSON String der als Wert in dem Datenpunkt steht hier rein.

                        69f2aac4-7b00-4231-b9b4-648e5b13ce6a-image.png

                        Thomas Braun 1 Reply Last reply Reply Quote 0
                        • Thomas Braun
                          Thomas Braun Most Active @mickym last edited by Thomas Braun

                          @mickym

                          Keine Ahnung was du brauchst...

                          0_userdata.0.solix.solarbank_info.total_battery_power
                          
                          total_battery_power
                          

                          Da steht sonst unter value nur noch

                          0.61

                          drin. Und den will ich ja mit 100 multiplizieren. Das JSON wird davor noch per skript in Einzelerte zerlegt. Fällt mir gerade ein... g

                          mickym 1 Reply Last reply Reply Quote 0
                          • mickym
                            mickym Most Active @Thomas Braun last edited by mickym

                            @thomas-braun

                            Da steht sonst nur noch

                            0.61

                            Ah OK dann ist das aber kein JSON mehr sondern wirklich ein numerischer Wert. Dann stell doch einfach mal den Datenpunkt auf Typ Zahl um.
                            Also Bleistift rechts und dann Typ ändern.

                            7e59f085-599a-4ee0-bb41-e9754774ac17-image.png

                            Thomas Braun 1 Reply Last reply Reply Quote 0
                            • Thomas Braun
                              Thomas Braun Most Active @mickym last edited by

                              @mickym sagte in source does not exist for "read" function:

                              Ah OK dann ist das aber kein JSON mehr sondern wirklich ein numerischer Wert.

                              Das JSON wird zuvor schon in Einzelwerte zerlegt.

                              Dann stell doch einfach mal den Datenpunkt auf Typ Zahl um.

                              Das funktioniert genau einmal. Die nächste Übermittlung des Wertes ist wieder ein String.

                              mickym 1 Reply Last reply Reply Quote 0
                              • mickym
                                mickym Most Active @Thomas Braun last edited by

                                @thomas-braun OK dann fallen mit noch 2 Möglichkeiten ein.

                                1. Du stellst den Datentyp auf "Mixed" - würde ich präferieren
                                2. Du konvertierst halt dann in der Aliasfunktion noch
                                Number(val) * 100
                                

                                Ich schau mal ob man dem mqtt-Client noch was einstellen kann.

                                Thomas Braun 1 Reply Last reply Reply Quote 0
                                • Thomas Braun
                                  Thomas Braun Most Active @mickym last edited by

                                  @mickym

                                  Ich glaube, jetzt geht es...
                                  Hab noch 'irgendwo irgendwas' umgestellt, jetzt erscheint auch im echarts der richtige Prozentwert.
                                  Mal schauen ob es einen Neustart auch übersteht...

                                  mickym 1 Reply Last reply Reply Quote 0
                                  • mickym
                                    mickym Most Active @Thomas Braun last edited by

                                    @thomas-braun Welche Methode hast Du verwendet?

                                    Thomas Braun 1 Reply Last reply Reply Quote 0
                                    • paul53
                                      paul53 @Thomas Braun last edited by

                                      @thomas-braun sagte: Wo in der Kette konvertiere ich den String am besten in ein Zahlenformat

                                      Die Multiplikation mit 100 im Alias konvertiert implizit den String in eine Zahl.
                                      Die Meldung "does not exist" sieht eher danach aus, als dass es den DP "0_userdata.0.solix.solarbank_info.total_battery_power" nicht (mehr) gibt.

                                      Thomas Braun Homoran 2 Replies Last reply Reply Quote 0
                                      • Thomas Braun
                                        Thomas Braun Most Active @mickym last edited by

                                        @mickym

                                        Ich kann es wirklich nicht sagen.
                                        Planloses herumgeklicke von mir in der Admin-GUI.

                                        mickym 1 Reply Last reply Reply Quote 0
                                        • Thomas Braun
                                          Thomas Braun Most Active @paul53 last edited by

                                          @paul53 sagte in source does not exist for "read" function:

                                          Die Meldung "does not exist" sieht eher danach aus, als dass es den DP "0_userdata.0.solix.solarbank_info.total_battery_power" nicht (mehr) gibt.

                                          Doch, den gibt und gab es.

                                          1 Reply Last reply Reply Quote 0
                                          • mickym
                                            mickym Most Active @Thomas Braun last edited by

                                            @thomas-braun sagte in source does not exist for "read" function:

                                            Planloses herumgeklicke von mir in der Admin-GUI.

                                            😀 😂 🤣

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            941
                                            Online

                                            31.7k
                                            Users

                                            79.7k
                                            Topics

                                            1.3m
                                            Posts

                                            4
                                            52
                                            1088
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo