    4. [Neuer Adapter] Proxmox VM

    NEWS

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    • Monatsrückblick - April 2025

    [Neuer Adapter] Proxmox VM

    This topic has been deleted. Only users with topic management privileges can see it.
    • M
      mrjeschke @Neuschwansteini last edited by mrjeschke

      @ilovegym
      Habe gerade getestet, mit der stable-Version vom admin-Adapter passiert das nicht.

      Edit: Ich habe dieses Verhalten ab Admin v7.4.15

      T 1 Reply Last reply Reply Quote 2
      • T
        TT-Tom @mrjeschke last edited by

        @ilovegym

        Ich kann das Verhalten bestätigen. Issue ist angelegt worden von @Feuersturm

        mcm1957 1 Reply Last reply Reply Quote 0
        • mcm1957
          mcm1957 @TT-Tom last edited by

          @tt-tom said in [Neuer Adapter] Proxmox VM:

          @ilovegym

          Ich kann das Verhalten bestätigen. Issue ist angelegt worden von @Feuersturm

          Das Problem ist nicht im Adapter zu suchen sondern in admin:
          https://github.com/ioBroker/ioBroker.admin/issues/2931

          mcm1957 created this issue in ioBroker/ioBroker.admin

          closed [bug]: jsonConfig - text fields within table loose focus after every character #2931

          1 Reply Last reply Reply Quote 3
          • T
            ticaki Developer @arteck last edited by ticaki

            @arteck

            Bitte man das nächste Mal mindestens ein minor update für sowas. Patches lass ich autoinstallieren und hab jetzt nicht erwartet dass da ein Benutzereingriff erforderlich ist. 🙂

            Edit: ah gesehen das ein Major hinterher kam.

            1 Reply Last reply Reply Quote 0
            • Negalein
              Negalein Global Moderator @arteck last edited by

              @arteck sagte in [Neuer Adapter] Proxmox VM:

              es gibt eine neue Version auf GIT...

              hab diese War ung im Log. Kann jetzt aber nicht sagen, ob die mit früheren Versionen auch schon war.

              2025-01-28 10:37:32.009	warn	Using Proxmox API: https://10.0.1.201:8006/api2/json
              
              Neuschwansteini 1 Reply Last reply Reply Quote 0
              • Neuschwansteini
                Neuschwansteini @Negalein last edited by

                @negalein ja war frueher auch schon, kann aber als Info angesehen werden... 🙂 ist ja nur ne Mitteilung, welche Node er jetzt abfragt..

                1 Reply Last reply Reply Quote 2
                • S
                  saeft_2003 Most Active last edited by

                  Ich hatte mit der aktuellen stable version das Problem das keine Daten mehr kommen.

                  Dann bin ich auf die 4.2.0 von github, damit kommen zumindest bis jetzt wieder Daten an.

                  Allerdings hab ich seitdem folgende Error im log. Ist das bekannt?

                  
                  2025-02-05 05:08:51.235 - error: proxmox.1 (763211) Problem with getStorageStatus. undefined
                  2025-02-05 05:08:51.239 - error: proxmox.1 (763211) Storage: local-lvm on storage/pve/local-lvm not available
                  2025-02-05 05:08:54.251 - error: proxmox.1 (763211) Problem with getStorageStatus. undefined
                  2025-02-05 05:08:54.251 - error: proxmox.1 (763211) Storage: PBS-Cloud on storage/pve/PBS-Cloud not available
                  2025-02-05 07:09:31.093 - error: proxmox.1 (763211) Problem with getStorageStatus. undefined
                  2025-02-05 07:09:31.095 - error: proxmox.1 (763211) Storage: local-lvm on storage/pve/local-lvm not available
                  2025-02-05 07:09:34.104 - error: proxmox.1 (763211) Problem with getStorageStatus. undefined
                  2025-02-05 07:09:34.104 - error: proxmox.1 (763211) Storage: local on storage/pve/local not available
                  2025-02-05 07:09:37.117 - error: proxmox.1 (763211) Problem with getStorageStatus. undefined
                  2025-02-05 07:09:37.117 - error: proxmox.1 (763211) Storage: PBS-Cloud on storage/pve/PBS-Cloud not available
                  
                  
                  A arteck 2 Replies Last reply Reply Quote 0
                  • A
                    Aiouh @saeft_2003 last edited by

                    Weiss jemand woher der Adapter den WEAROUT bekommt? Mit den smartmontools (db ist aktuell) gibt es gar keinen wearout parameter.
                    Jetzt bin ich leicht verunsichert, ob 83% remaining life sind oder used up life...

                    cad3acb8-0d88-4ddb-ad05-f819d92788f5-image.png

                    smartctl -a /dev/nvme0n1
                    smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.8.12-2-pve] (local build)
                    Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
                    
                    === START OF INFORMATION SECTION ===
                    Model Number:                       SAMSUNG MZVPW256HEGL-000H1
                    Serial Number:                      S34XXB0J304511
                    Firmware Version:                   CXZ73H0Q
                    PCI Vendor/Subsystem ID:            0x144d
                    IEEE OUI Identifier:                0x002538
                    Total NVM Capacity:                 256,060,514,304 [256 GB]
                    Unallocated NVM Capacity:           0
                    Controller ID:                      2
                    NVMe Version:                       1.2
                    Number of Namespaces:               1
                    Namespace 1 Size/Capacity:          256,060,514,304 [256 GB]
                    Namespace 1 Formatted LBA Size:     512
                    Namespace 1 IEEE EUI-64:            002538 c371b06d66
                    Local Time is:                      Fri Feb  7 09:24:40 2025 CET
                    Firmware Updates (0x16):            3 Slots, no Reset required
                    Optional Admin Commands (0x0017):   Security Format Frmw_DL Self_Test
                    Optional NVM Commands (0x001f):     Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
                    Log Page Attributes (0x03):         S/H_per_NS Cmd_Eff_Lg
                    Warning  Comp. Temp. Threshold:     70 Celsius
                    Critical Comp. Temp. Threshold:     73 Celsius
                    
                    Supported Power States
                    St Op     Max   Active     Idle   RL RT WL WT  Ent_Lat  Ex_Lat
                     0 +     6.80W       -        -    0  0  0  0        0       0
                     1 +     5.60W       -        -    1  1  1  1        0       0
                     2 +     4.40W       -        -    2  2  2  2        0       0
                     3 -   0.0400W       -        -    3  3  3  3      210    1500
                     4 -   0.0050W       -        -    4  4  4  4     2200    6000
                    
                    Supported LBA Sizes (NSID 0x1)
                    Id Fmt  Data  Metadt  Rel_Perf
                     0 +     512       0         0
                    
                    === START OF SMART DATA SECTION ===
                    SMART overall-health self-assessment test result: PASSED
                    
                    SMART/Health Information (NVMe Log 0x02)
                    Critical Warning:                   0x00
                    Temperature:                        18 Celsius
                    Available Spare:                    100%
                    Available Spare Threshold:          5%
                    Percentage Used:                    17%
                    Data Units Read:                    19,332,739 [9.89 TB]
                    Data Units Written:                 52,368,948 [26.8 TB]
                    Host Read Commands:                 264,060,029
                    Host Write Commands:                3,047,803,025
                    Controller Busy Time:               16,045
                    Power Cycles:                       286
                    Power On Hours:                     35,119
                    Unsafe Shutdowns:                   64
                    Media and Data Integrity Errors:    0
                    Error Information Log Entries:      1,128
                    Warning  Comp. Temperature Time:    0
                    Critical Comp. Temperature Time:    0
                    Temperature Sensor 1:               18 Celsius
                    Temperature Sensor 2:               23 Celsius
                    
                    Error Information (NVMe Log 0x01, 16 of 64 entries)
                    Num   ErrCount  SQId   CmdId  Status  PELoc          LBA  NSID    VS
                      0       1128     0  0x0009  0x4004      -            0     0     -
                      1       1127     0  0x3016  0x4004      -            0     0     -
                      2       1126     0  0x3006  0x4004      -            0     0     -
                      3       1125     0  0x0008  0x4004      -            0     0     -
                      4       1124     0  0x0014  0x4004      -            0     0     -
                      5       1123     0  0x1011  0x4004      -            0     0     -
                      6       1122     0  0x3012  0x4004      -            0     0     -
                      7       1121     0  0x701c  0x4004      -            0     0     -
                      8       1120     0  0x0008  0x4004      -            0     0     -
                      9       1119     0  0x001b  0x4004      -            0     0     -
                     10       1118     0  0x301a  0x4004      -            0     0     -
                     11       1117     0  0x3000  0x4004      -            0     0     -
                     12       1116     0  0x301a  0x4004      -            0     0     -
                     13       1115     0  0x0016  0x4004      -            0     0     -
                     14       1114     0  0x301a  0x4004      -            0     0     -
                     15       1113     0  0x3002  0x4004      -            0     0     -
                    ... (48 entries not read)
                    
                    
                    Dr. Bakterius 1 Reply Last reply Reply Quote 0
                    • Dr. Bakterius
                      Dr. Bakterius Most Active @Aiouh last edited by Dr. Bakterius

                      @aiouh sagte in [Neuer Adapter] Proxmox VM:

                      Mit den smartmontools (db ist aktuell) gibt es gar keinen wearout parameter.

                      Doch. Hier:

                      Percentage Used:                    17%
                      

                      Jetzt bin ich leicht verunsichert, ob 83% remaining life sind oder used up life...

                      Somit sind noch 83% "Lebenszeit" übrig. Das ist aber nur ein Richtwert und der richtet sich nach TBW die der Hersteller angibt. In deinem Fall wohl ca. 150 TB. Also das Verhältnis der TWB zu:

                      Data Units Written:                 52,368,948 [26.8 TB]
                      

                      Natürlich kann das Laufwerk schon vorher defekt werden oder auch viel länger seinen Dienst tun.

                      A 1 Reply Last reply Reply Quote 1
                      • A
                        Aiouh @Dr. Bakterius last edited by

                        @dr-bakterius danke, dann werde ich das einfach im Auge behalten

                        1 Reply Last reply Reply Quote 0
                        • arteck
                          arteck Developer Most Active @saeft_2003 last edited by

                          @saeft_2003 sagte in [Neuer Adapter] Proxmox VM:

                          Ich hatte mit der aktuellen stable version das Problem das keine Daten mehr kommen.

                          Dann bin ich auf die 4.2.0 von github, damit kommen zumindest bis jetzt wieder Daten an.

                          Allerdings hab ich seitdem folgende Error im log. Ist das bekannt?

                          was soll da bekannt/unbekannt sein.. dein Problem steht doch da ..

                          S 1 Reply Last reply Reply Quote 0
                          • S
                            saeft_2003 Most Active @arteck last edited by

                            @arteck

                            Ja das Problem steht da aber es gibt keins, vor dem git update gab es diese Fehlermeldungen auch nicht.

                            Verstehst du was ich meine?

                            arteck 1 Reply Last reply Reply Quote 0
                            • arteck
                              arteck Developer Most Active @saeft_2003 last edited by

                              @saeft_2003 stell den adapeter mal auf debug

                              1 Reply Last reply Reply Quote 0
                              • First post
                                Last post

                              Support us

                              ioBroker
                              Community Adapters
                              Donate

                              772
                              Online

                              31.7k
                              Users

                              79.8k
                              Topics

                              1.3m
                              Posts

                              proxmox
                              74
                              484
                              89723
                              Loading More Posts
                              • Oldest to Newest
                              • Newest to Oldest
                              • Most Votes
                              Reply
                              • Reply as topic
                              Log in to reply
                              Community
                              Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                              The ioBroker Community 2014-2023
                              logo