Navigation

    Logo
    • Register
    • Login
    • Search
    • Recent
    • Tags
    • Unread
    • Categories
    • Unreplied
    • Popular
    • GitHub
    • Docu
    • Hilfe
    1. Home
    2. Deutsch
    3. Einsteigerfragen
    4. Einbindung von Geräten
    5. Modbus EasyCharge Einstellungen

    NEWS

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    • Monatsrückblick - April 2025

    Modbus EasyCharge Einstellungen

    This topic has been deleted. Only users with topic management privileges can see it.
    • Homoran
      Homoran Global Moderator Administrators @Mark last edited by

      @mark sagte in Modbus EasyCharge Einstellungen:

      Error response for FCx3: Illegal Data Address

      hast du noch Leichen auf snderen Tabs des Adapters?

      M 1 Reply Last reply Reply Quote 0
      • M
        Mark @Homoran last edited by Mark

        @homoran said in Modbus EasyCharge Einstellungen:

        @mark sagte in Modbus EasyCharge Einstellungen:

        Error response for FCx3: Illegal Data Address

        hast du noch Leichen auf snderen Tabs des Adapters?

        Ich hab nur den einen modbus adapter und auch nur eine Instanz. Angeschlossen ist auch nur das Board.

        mit den Einstellungen 8,1,even kommt

        modbus.0
        	2025-02-09 21:31:35.192	debug	Cleaning up request fifo.
        modbus.0
        	2025-02-09 21:31:35.190	debug	Clearing timeout of the current request.
        modbus.0
        	2025-02-09 21:31:35.185	info	Disconnected from slave
        modbus.0
        	2025-02-09 21:31:34.178	warn	[DevID_2] Poll error count: 1 code: {"err":"timeout","timeout":5000}
        modbus.0
        	2025-02-09 21:31:34.173	error	Request timed out.
        modbus.0
        	2025-02-09 21:31:34.171	warn	Error: undefined
        modbus.0
        	2025-02-09 21:31:29.155	debug	[DevID_2/holdingRegs] Poll address 40035 - 1 registers
        modbus.0
        	2025-02-09 21:31:29.153	debug	Initialization of scale factors done!
        modbus.0
        	2025-02-09 21:31:29.148	debug	[DevID_2] Poll start ---------------------
        modbus.0
        	2025-02-09 21:31:29.145	info	Connected to slave
        modbus.0
        	2025-02-09 21:31:29.116	debug	connect to serial /dev/ttyUSB0 with 9600
        modbus.0
        	2025-02-09 21:31:28.545	debug	Add holdingRegisters.40035_Temperatur: {"_id":"holdingRegisters.40035_Temperatur","type":"state","common":{"name":"Temperatur","role":"value","type":"number","read":true,"write":true,"def":0,"unit":""},"native":{"regType":"holdingRegs","address":40035,"deviceId":2,"type":"uint16be","len":1,"offset":0,"factor":1,"poll":true}}
        modbus.0
        	2025-02-09 21:31:28.543	debug	Initialize Objects for holdingRegs: [{"_address":"40035","name":"Temperatur","description":"Temperatur","unit":"","type":"uint16be","len":1,"factor":1,"offset":0,"formula":"","role":"value","room":"","poll":true,"wp":"","cw":"","isScale":"","address":40035,"deviceId":2,"id":"holdingRegisters.40035_Temperatur"}]
        modbus.0
        	2025-02-09 21:31:28.542	debug	Initialize Objects for inputRegs: []
        modbus.0
        	2025-02-09 21:31:28.539	debug	Initialize Objects for coils: []
        modbus.0
        	2025-02-09 21:31:28.537	debug	Initialize Objects for disInputs: []
        modbus.0
        	2025-02-09 21:31:28.216	info	starting. Version 6.3.2 in /opt/iobroker/node_modules/iobroker.modbus, node: v18.17.1, js-controller: 7.0.6
        modbus.0
        	2025-02-09 21:31:27.245	debug	Plugin sentry Initialize Plugin (enabled=true)
        host.michi
        	2025-02-09 21:31:22.951	info	instance system.adapter.modbus.0 in version "6.3.2" started with pid 1209
        host.michi
        	2025-02-09 21:31:21.925	info	"system.adapter.modbus.0" enabled
        admin.0
        	2025-02-09 21:31:15.087	info	<== Disconnect system.user.admin from ::ffff:192.168.188.158 modbus
        admin.0
        	2025-02-09 21:30:59.851	info	==> Connected system.user.admin from ::ffff:192.168.188.158
        
        wendy2702 Homoran 2 Replies Last reply Reply Quote 0
        • wendy2702
          wendy2702 @Mark last edited by

          @mark steht das eine Register jetzt bei Holding?

          Wenn ja stelle es mal bei Eingangs Register ein

          M 1 Reply Last reply Reply Quote 0
          • M
            Mark @wendy2702 last edited by

            @wendy2702 said in Modbus EasyCharge Einstellungen:

            @mark steht das eine Register jetzt bei Holding?

            Wenn ja stelle es mal bei Eingangs Register ein

            kommt genau das selbe.
            Egal ob mit none oder even, egal ob als Eingang oder Holding

            wendy2702 Homoran 2 Replies Last reply Reply Quote 0
            • wendy2702
              wendy2702 @Mark last edited by

              @mark Probier mal ein anderes Register. Vielleicht geht das eine gerade nicht

              M 1 Reply Last reply Reply Quote 0
              • Homoran
                Homoran Global Moderator Administrators @Mark last edited by

                @mark sagte in Modbus EasyCharge Einstellungen:

                Ich hab nur den einen modbus adapter und auch nur eine Instanz

                und da steht nur unter holding nur der eine Eintrag?

                1 Reply Last reply Reply Quote 0
                • M
                  Mark @wendy2702 last edited by

                  @wendy2702 said in Modbus EasyCharge Einstellungen:

                  @mark Probier mal ein anderes Register. Vielleicht geht das eine gerade nicht

                  Hab schon 40155 probiert. Da müsste eigentlich eine 5 zurückkommen. Geht aber auch nicht

                  1 Reply Last reply Reply Quote 0
                  • Homoran
                    Homoran Global Moderator Administrators last edited by

                    Stop!
                    ihr hängt mich ab 😁

                    zuerst kam illegal address
                    Screenshot_20250209-214210_Firefox.jpg

                    in Verbindung mit function code 3.

                    Das ist read holding register
                    Screenshot_20250209-214137_Firefox.jpg

                    also "eigentlich" alles richtig

                    mit even statt none war das weg

                    richtig?

                    M Homoran 2 Replies Last reply Reply Quote 0
                    • Homoran
                      Homoran Global Moderator Administrators @Mark last edited by

                      @mark sagte in Modbus EasyCharge Einstellungen:

                      kommt genau das selbe.
                      Egal ob mit none oder even,

                      eben nicht!

                      1 Reply Last reply Reply Quote 0
                      • M
                        Mark @Homoran last edited by

                        @homoran said in Modbus EasyCharge Einstellungen:

                        Stop!
                        ihr hängt mich ab 😁

                        zuerst kam illegal address
                        Screenshot_20250209-214210_Firefox.jpg

                        in Verbindung mit function code 3.

                        Das ist read holding register
                        Screenshot_20250209-214137_Firefox.jpg

                        also "eigentlich" alles richtig

                        mit even statt none war das weg

                        richtig?

                        Ja, richtig.
                        Mit dem egal meinte ich, dass bei even immer das selbe kommt (egal welches Register) und bei none kommt auch das selbe (egal welches Register). Aber even und none produzieren unterschiedliche Fehler

                        wendy2702 Homoran 2 Replies Last reply Reply Quote 0
                        • wendy2702
                          wendy2702 @Mark last edited by wendy2702

                          @mark laut deiner Beschreibung ist „none“ richtig.

                          Also damit mal ein Register bei Holding eintragen und log zeigen oder mal a/b tauschen und testen

                          1 Reply Last reply Reply Quote 0
                          • Homoran
                            Homoran Global Moderator Administrators @Mark last edited by

                            @mark sagte in Modbus EasyCharge Einstellungen:

                            Mit dem egal meinte ich, dass bei even immer das selbe kommt (egal welches Register) und bei none kommt auch das selbe (egal welches Register). Aber even und none produzieren unterschiedliche Fehler

                            ja das passt!
                            even war laut Registertanelle fettgedruckt = Werkseinstellumg!?
                            Also bleiben wir erst mal dabei.

                            dieses dämliche

                            @mark sagte in Modbus EasyCharge Einstellungen:

                            2025-02-09 21:31:34.171 warn Error: undefined

                            hatten wir in einem anderen Fall schon mal.
                            Ich kann mich nur nicht erinnern warum, und ob das gelöst wurde

                            wendy2702 Homoran 2 Replies Last reply Reply Quote 0
                            • wendy2702
                              wendy2702 @Homoran last edited by

                              @homoran nö, nix Even.

                              Laut seiner Beschreibung—> keine parität

                              M Homoran 2 Replies Last reply Reply Quote 0
                              • M
                                Mark @wendy2702 last edited by

                                @wendy2702 said in Modbus EasyCharge Einstellungen:

                                @homoran nö, nix Even.

                                Laut seiner Beschreibung—> keine parität

                                Einstellung: none, Holding 40035 mit Abfrage:

                                modbus.0
                                	2025-02-09 21:55:26.201	debug	Cleaning up request fifo.
                                modbus.0
                                	2025-02-09 21:55:26.199	debug	Clearing timeout of the current request.
                                modbus.0
                                	2025-02-09 21:55:26.193	info	Disconnected from slave
                                modbus.0
                                	2025-02-09 21:55:25.193	warn	[DevID_2] Poll error count: 1 code: {"err":"timeout","timeout":5000}
                                modbus.0
                                	2025-02-09 21:55:25.187	error	Request timed out.
                                modbus.0
                                	2025-02-09 21:55:25.184	warn	Error: undefined
                                modbus.0
                                	2025-02-09 21:55:20.219	error	Error response: Data address of some or all the required entities are not allowed or do not exist in slave
                                modbus.0
                                	2025-02-09 21:55:20.217	error	Error response for FCx3: Illegal Data Address
                                modbus.0
                                	2025-02-09 21:55:20.169	debug	[DevID_2/holdingRegs] Poll address 40035 - 1 registers
                                modbus.0
                                	2025-02-09 21:55:20.166	debug	Initialization of scale factors done!
                                modbus.0
                                	2025-02-09 21:55:20.161	debug	[DevID_2] Poll start ---------------------
                                modbus.0
                                	2025-02-09 21:55:20.159	info	Connected to slave
                                modbus.0
                                	2025-02-09 21:55:20.141	debug	connect to serial /dev/ttyUSB0 with 9600
                                modbus.0
                                	2025-02-09 21:55:19.578	debug	Add holdingRegisters.40035_Temp: {"_id":"holdingRegisters.40035_Temp","type":"state","common":{"name":"Temp","role":"level","type":"number","read":true,"write":true,"def":0,"unit":""},"native":{"regType":"holdingRegs","address":40035,"deviceId":2,"type":"uint16be","len":1,"offset":0,"factor":1,"poll":true}}
                                modbus.0
                                	2025-02-09 21:55:19.576	debug	Initialize Objects for holdingRegs: [{"_address":"40035","name":"Temp","description":"Temp","unit":"","type":"uint16be","len":1,"factor":1,"offset":0,"formula":"","role":"level","room":"","poll":true,"wp":"","cw":"","isScale":"","address":40035,"deviceId":2,"id":"holdingRegisters.40035_Temp"}]
                                modbus.0
                                	2025-02-09 21:55:19.575	debug	Initialize Objects for inputRegs: []
                                modbus.0
                                	2025-02-09 21:55:19.572	debug	Initialize Objects for coils: []
                                modbus.0
                                	2025-02-09 21:55:19.570	debug	Initialize Objects for disInputs: []
                                modbus.0
                                	2025-02-09 21:55:19.249	info	starting. Version 6.3.2 in /opt/iobroker/node_modules/iobroker.modbus, node: v18.17.1, js-controller: 7.0.6
                                modbus.0
                                	2025-02-09 21:55:18.308	debug	Plugin sentry Initialize Plugin (enabled=true)
                                modbus.0
                                	2025-02-09 21:55:18.241	debug	States connected to redis: 127.0.0.1:9000
                                modbus.0
                                	2025-02-09 21:55:18.213	debug	States create User PubSub Client
                                modbus.0
                                	2025-02-09 21:55:18.211	debug	States create System PubSub Client
                                modbus.0
                                	2025-02-09 21:55:18.195	debug	Redis States: Use Redis connection: 127.0.0.1:9000
                                modbus.0
                                	2025-02-09 21:55:18.158	debug	Objects connected to redis: 127.0.0.1:9001
                                modbus.0
                                	2025-02-09 21:55:18.139	debug	Objects client initialize lua scripts
                                modbus.0
                                	2025-02-09 21:55:18.095	debug	Objects create User PubSub Client
                                modbus.0
                                	2025-02-09 21:55:18.092	debug	Objects create System PubSub Client
                                modbus.0
                                	2025-02-09 21:55:18.086	debug	Objects client ready ... initialize now
                                modbus.0
                                	2025-02-09 21:55:18.019	debug	Redis Objects: Use Redis connection: 127.0.0.1:9001
                                host.michi
                                	2025-02-09 21:55:14.149	info	instance system.adapter.modbus.0 in version "6.3.2" started with pid 1477
                                host.michi
                                	2025-02-09 21:55:13.101	info	"system.adapter.modbus.0" enabled
                                admin.0
                                	2025-02-09 21:55:05.799	info	<== Disconnect system.user.admin from ::ffff:192.168.188.158 modbus
                                admin.0
                                	2025-02-09 21:54:13.438	info	==> Connected system.user.admin from ::ffff:192.168.188.158
                                
                                1 Reply Last reply Reply Quote 0
                                • Homoran
                                  Homoran Global Moderator Administrators @wendy2702 last edited by Homoran

                                  @wendy2702 sagte in Modbus EasyCharge Einstellungen:

                                  @homoran nö, nix Even.

                                  Laut seiner Beschreibung—> keine parität

                                  aber in der Registerbeschreibung ist die Zeile mit even fettgedruckt = Werkseinstellung

                                  und einen Fall mit undefined hatte ich gerade über die Suche gefunden.
                                  Da war der Stick defekt 😞

                                  wendy2702 1 Reply Last reply Reply Quote 0
                                  • wendy2702
                                    wendy2702 @Homoran last edited by

                                    @homoran tolle Dokumentation wenn mal none und mal even angegeben ist.

                                    Vielleicht ist der Stick auch gegrillt nachdem er falsch angeschlossen war.

                                    M 1 Reply Last reply Reply Quote 1
                                    • Homoran
                                      Homoran Global Moderator Administrators last edited by

                                      Man könnte noch

                                      • Leitungen A/B tauschen
                                      • Die Anzahl auf einmal gelesene Register begrenzen
                                        • einige Geräte brauchen das
                                          Screenshot_20250209-220444_Firefox.jpg
                                      1 Reply Last reply Reply Quote 0
                                      • M
                                        Mark @wendy2702 last edited by

                                        @wendy2702 said in Modbus EasyCharge Einstellungen:

                                        @homoran tolle Dokumentation wenn mal none und mal even angegeben ist.

                                        Vielleicht ist der Stick auch gegrillt nachdem er falsch angeschlossen war.

                                        Würde ich ausschließen. Hab gerade einen 2. (selbe Marke) getestet. Gleiches Ergebnis.

                                        Homoran 1 Reply Last reply Reply Quote 1
                                        • Homoran
                                          Homoran Global Moderator Administrators @Mark last edited by

                                          @mark ne Kontrollleuchte hat der nicht?

                                          M 1 Reply Last reply Reply Quote 0
                                          • M
                                            Mark @Homoran last edited by

                                            @homoran said in Modbus EasyCharge Einstellungen:

                                            @mark ne Kontrollleuchte hat der nicht?

                                            nein.

                                            Homoran 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            901
                                            Online

                                            31.7k
                                            Users

                                            79.7k
                                            Topics

                                            1.3m
                                            Posts

                                            modbus-adapter
                                            3
                                            79
                                            2312
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo