    JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.

    This topic has been deleted. Only users with topic management privileges can see it.
    • Elektroniker86
      Elektroniker86 @wendy2702 last edited by

      @wendy2702

      Moment da hat sich was überschnitten Das ist jetzt aktuell.

      Screenshot 2025-03-06 170913.png Screenshot 2025-03-06 170846.png Screenshot 2025-03-06 170813.png

      
      modbus.5
      2025-03-06 17:10:00.444	info	Disconnected from slave 192.168.1.123
      
      modbus.5
      2025-03-06 17:09:59.443	warn	[DevID_1] Poll error count: 3 code: {"err":"timeout","timeout":5000}
      
      modbus.5
      2025-03-06 17:09:59.443	error	Client in error state.
      
      modbus.5
      2025-03-06 17:09:59.443	error	Request timed out.
      
      modbus.5
      2025-03-06 17:09:59.442	warn	Error: undefined
      
      modbus.5
      2025-03-06 17:09:53.391	warn	[DevID_1] Poll error count: 2 code: "ReadInputRegisters: Invalid FC 32"
      
      modbus.5
      2025-03-06 17:09:53.390	warn	Error in handler for 4: RangeError [ERR_BUFFER_OUT_OF_BOUNDS]: Attempt to access memory outside buffer bounds
      
      modbus.5
      2025-03-06 17:09:53.390	warn	Error in handler for 4: RangeError [ERR_BUFFER_OUT_OF_BOUNDS]: Attempt to access memory outside buffer bounds
      
      modbus.5
      2025-03-06 17:09:48.990	warn	[DevID_1] Poll error count: 1 code: "App Timeout"
      
      modbus.5
      2025-03-06 17:09:43.902	warn	Error in handler for 4: RangeError [ERR_BUFFER_OUT_OF_BOUNDS]: Attempt to access memory outside buffer bounds
      
      modbus.5
      2025-03-06 17:09:43.788	info	Connected to slave 192.168.1.123
      
      modbus.5
      2025-03-06 17:09:43.634	info	starting. Version 6.3.2 in /opt/iobroker/node_modules/iobroker.modbus, node: v20.18.3, js-controller: 7.0.6
      
      modbus.5
      2025-03-06 17:09:39.643	info	terminating
      
      modbus.5
      2025-03-06 17:09:39.159	info	Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
      
      modbus.5
      2025-03-06 17:09:39.158	info	terminating
      
      modbus.5
      2025-03-06 17:09:39.142	info	Got terminate signal TERMINATE_YOURSELF
      
      
      Homoran 1 Reply Last reply Reply Quote 0
      • Homoran
        Homoran Global Moderator Administrators @Elektroniker86 last edited by

        @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

        Das ist jetzt aktuell.

        bitte erst einmal nur ein Register abrufen.
        Input <-> Holding gilt immer noch

        Elektroniker86 1 Reply Last reply Reply Quote 0
        • Elektroniker86
          Elektroniker86 @Homoran last edited by

          @homoran

          So, ein Register und Debug:

          
          modbus.5
          2025-03-06 17:14:13.892	info	Disconnected from slave 192.168.1.123
          
          modbus.5
          2025-03-06 17:14:13.892	debug	Closing client on purpose.
          
          modbus.5
          2025-03-06 17:14:12.892	debug	Cleaning up request fifo.
          
          modbus.5
          2025-03-06 17:14:12.892	debug	Clearing timeout of the current request.
          
          modbus.5
          2025-03-06 17:14:12.892	debug	Socket closed with error
          
          modbus.5
          2025-03-06 17:14:12.891	warn	[DevID_1] Poll error count: 3 code: {"err":"timeout","timeout":5000}
          
          modbus.5
          2025-03-06 17:14:12.891	error	Client in error state.
          
          modbus.5
          2025-03-06 17:14:12.891	error	Request timed out.
          
          modbus.5
          2025-03-06 17:14:12.891	warn	Error: undefined
          
          modbus.5
          2025-03-06 17:14:07.890	debug	[DevID_1/inputRegs] Poll address 4752 - 2 registers
          
          modbus.5
          2025-03-06 17:14:07.889	debug	[DevID_1] Poll start ---------------------
          
          modbus.5
          2025-03-06 17:14:06.839	warn	[DevID_1] Poll error count: 2 code: "ReadInputRegisters: Invalid FC 32"
          
          modbus.5
          2025-03-06 17:14:04.028	debug	[DevID_1/inputRegs] Poll address 4752 - 2 registers
          
          modbus.5
          2025-03-06 17:14:04.028	debug	[DevID_1] Poll start ---------------------
          
          modbus.5
          2025-03-06 17:14:02.975	warn	[DevID_1] Poll error count: 1 code: "App Timeout"
          
          modbus.5
          2025-03-06 17:13:57.793	warn	Error in handler for 4: RangeError [ERR_BUFFER_OUT_OF_BOUNDS]: Attempt to access memory outside buffer bounds
          
          modbus.5
          2025-03-06 17:13:57.776	debug	[DevID_1/inputRegs] Poll address 4752 - 2 registers
          
          modbus.5
          2025-03-06 17:13:57.776	debug	Initialization of scale factors done!
          
          modbus.5
          2025-03-06 17:13:57.775	debug	[DevID_1] Poll start ---------------------
          
          modbus.5
          2025-03-06 17:13:57.775	info	Connected to slave 192.168.1.123
          
          modbus.5
          2025-03-06 17:13:57.721	debug	Remove old object modbus.5.inputRegisters.4774_soc
          
          modbus.5
          2025-03-06 17:13:57.677	debug	Initialize Objects for holdingRegs: []
          
          modbus.5
          2025-03-06 17:13:57.677	debug	Add inputRegisters.4752_Total_Battery_Voltage: {"_id":"inputRegisters.4752_Total_Battery_Voltage","type":"state","common":{"name":"bat vol","role":"value","type":"number","read":true,"write":false,"def":0,"unit":"mV"},"native":{"regType":"inputRegs","address":4752,"deviceId":1,"type":"uint32be","len":2,"offset":0,"factor":1}}
          
          modbus.5
          2025-03-06 17:13:57.677	debug	Initialize Objects for inputRegs: [{"_address":4752,"deviceId":1,"name":"Total Battery Voltage","description":"bat vol","unit":"mV","type":"uint32be","len":2,"factor":1,"offset":0,"formula":"","role":"value","room":"","cw":false,"isScale":false,"address":4752,"id":"inputRegisters.4752_Total_Battery_Voltage"}]
          
          modbus.5
          2025-03-06 17:13:57.676	debug	Initialize Objects for coils: []
          
          modbus.5
          2025-03-06 17:13:57.676	debug	Initialize Objects for disInputs: []
          
          modbus.5
          2025-03-06 17:13:57.621	info	starting. Version 6.3.2 in /opt/iobroker/node_modules/iobroker.modbus, node: v20.18.3, js-controller: 7.0.6
          
          modbus.5
          2025-03-06 17:13:57.502	debug	Plugin sentry Initialize Plugin (enabled=true)
          
          modbus.5
          2025-03-06 17:13:57.487	debug	States connected to redis: 0.0.0.0:9000
          
          modbus.5
          2025-03-06 17:13:57.433	debug	States create User PubSub Client
          
          modbus.5
          2025-03-06 17:13:57.433	debug	States create System PubSub Client
          
          modbus.5
          2025-03-06 17:13:57.424	debug	Redis States: Use Redis connection: 0.0.0.0:9000
          
          modbus.5
          2025-03-06 17:13:57.406	debug	Objects connected to redis: 0.0.0.0:9001
          
          modbus.5
          2025-03-06 17:13:57.405	debug	Objects client initialize lua scripts
          
          modbus.5
          2025-03-06 17:13:57.376	debug	Objects create User PubSub Client
          
          modbus.5
          2025-03-06 17:13:57.376	debug	Objects create System PubSub Client
          
          modbus.5
          2025-03-06 17:13:57.375	debug	Objects client ready ... initialize now
          
          modbus.5
          2025-03-06 17:13:57.358	debug	Redis Objects: Use Redis connection: 0.0.0.0:9001
          
          modbus.5
          2025-03-06 17:13:53.655	info	terminating
          
          modbus.5
          2025-03-06 17:13:53.169	info	Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
          
          modbus.5
          2025-03-06 17:13:53.169	debug	Plugin sentry destroyed
          
          modbus.5
          2025-03-06 17:13:53.169	info	terminating
          
          modbus.5
          2025-03-06 17:13:53.154	debug	Closing client on purpose.
          
          modbus.5
          2025-03-06 17:13:53.154	info	Got terminate signal TERMINATE_YOURSELF
          
          Homoran 1 Reply Last reply Reply Quote 0
          • Homoran
            Homoran Global Moderator Administrators @Elektroniker86 last edited by

            @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

            Add inputRegisters

            bitte Holdingregister nehmen

            wendy2702 Elektroniker86 2 Replies Last reply Reply Quote 0
            • wendy2702
              wendy2702 @Homoran last edited by

              @homoran sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

              @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

              Add inputRegisters

              bitte Holdingregister nehmen

              Und besser beim Port 502 bleiben.

              @Elektroniker86 : gibt es bei dem Konverter noch ein erweitertes Menu oder kann man da wo TCP Server steht was anderes auswählen?

              Elektroniker86 1 Reply Last reply Reply Quote 0
              • Elektroniker86
                Elektroniker86 @Homoran last edited by

                @homoran

                Ich habe jetzt das Register beim Reiter Holding eingetragen. und bei eingang rausgelöscht. Hoffe das ist richtig so?

                modbus.5
                2025-03-06 17:28:01.562	info	Disconnected from slave 192.168.1.123
                
                modbus.5
                2025-03-06 17:28:01.562	debug	Closing client on purpose.
                
                modbus.5
                2025-03-06 17:28:00.563	debug	Cleaning up request fifo.
                
                modbus.5
                2025-03-06 17:28:00.563	debug	Clearing timeout of the current request.
                
                modbus.5
                2025-03-06 17:28:00.563	debug	Socket closed with error
                
                modbus.5
                2025-03-06 17:28:00.562	warn	[DevID_1] Poll error count: 3 code: {"err":"timeout","timeout":5000}
                
                modbus.5
                2025-03-06 17:28:00.562	error	Client in error state.
                
                modbus.5
                2025-03-06 17:28:00.562	error	Request timed out.
                
                modbus.5
                2025-03-06 17:28:00.561	warn	Error: undefined
                
                modbus.5
                2025-03-06 17:27:55.560	debug	[DevID_1/holdingRegs] Poll address 4752 - 2 registers
                
                modbus.5
                2025-03-06 17:27:55.560	debug	[DevID_1] Poll start ---------------------
                
                modbus.5
                2025-03-06 17:27:54.510	warn	[DevID_1] Poll error count: 2 code: "ReadHoldingRegisters: Invalid FC 32"
                
                modbus.5
                2025-03-06 17:27:54.428	debug	[DevID_1/holdingRegs] Poll address 4752 - 2 registers
                
                modbus.5
                2025-03-06 17:27:54.427	debug	[DevID_1] Poll start ---------------------
                
                modbus.5
                2025-03-06 17:27:53.377	warn	[DevID_1] Poll error count: 1 code: "App Timeout"
                
                modbus.5
                2025-03-06 17:27:48.324	warn	Error in handler for 3: RangeError [ERR_BUFFER_OUT_OF_BOUNDS]: Attempt to access memory outside buffer bounds
                
                modbus.5
                2025-03-06 17:27:48.178	debug	[DevID_1/holdingRegs] Poll address 4752 - 2 registers
                
                modbus.5
                2025-03-06 17:27:48.178	debug	Initialization of scale factors done!
                
                modbus.5
                2025-03-06 17:27:48.177	debug	[DevID_1] Poll start ---------------------
                
                modbus.5
                2025-03-06 17:27:48.177	info	Connected to slave 192.168.1.123
                
                modbus.5
                2025-03-06 17:27:48.083	debug	Add holdingRegisters.4752_Total_Battery_Voltage: {"_id":"holdingRegisters.4752_Total_Battery_Voltage","type":"state","common":{"name":"bat vol","role":"value","type":"number","read":true,"write":true,"def":0,"unit":"mV"},"native":{"regType":"holdingRegs","address":4752,"deviceId":1,"type":"uint32be","len":2,"offset":0,"factor":1,"poll":true}}
                
                modbus.5
                2025-03-06 17:27:48.083	debug	Initialize Objects for holdingRegs: [{"_address":"4752","name":"Total Battery Voltage","description":"bat vol","unit":"mV","type":"uint32be","len":2,"factor":1,"offset":0,"formula":"","role":"value","room":"","poll":true,"wp":false,"cw":false,"isScale":false,"deviceId":1,"address":4752,"id":"holdingRegisters.4752_Total_Battery_Voltage"}]
                
                modbus.5
                2025-03-06 17:27:48.083	debug	Initialize Objects for inputRegs: []
                
                modbus.5
                2025-03-06 17:27:48.083	debug	Initialize Objects for coils: []
                
                modbus.5
                2025-03-06 17:27:48.083	debug	Initialize Objects for disInputs: []
                
                modbus.5
                2025-03-06 17:27:48.025	info	starting. Version 6.3.2 in /opt/iobroker/node_modules/iobroker.modbus, node: v20.18.3, js-controller: 7.0.6
                
                modbus.5
                2025-03-06 17:27:47.911	debug	Plugin sentry Initialize Plugin (enabled=true)
                
                modbus.5
                2025-03-06 17:27:47.897	debug	States connected to redis: 0.0.0.0:9000
                
                modbus.5
                2025-03-06 17:27:47.844	debug	States create User PubSub Client
                
                modbus.5
                2025-03-06 17:27:47.843	debug	States create System PubSub Client
                
                modbus.5
                2025-03-06 17:27:47.795	debug	Redis States: Use Redis connection: 0.0.0.0:9000
                
                modbus.5
                2025-03-06 17:27:47.770	debug	Objects connected to redis: 0.0.0.0:9001
                
                modbus.5
                2025-03-06 17:27:47.768	debug	Objects client initialize lua scripts
                
                modbus.5
                2025-03-06 17:27:47.736	debug	Objects create User PubSub Client
                
                modbus.5
                2025-03-06 17:27:47.736	debug	Objects create System PubSub Client
                
                modbus.5
                2025-03-06 17:27:47.736	debug	Objects client ready ... initialize now
                
                modbus.5
                2025-03-06 17:27:47.719	debug	Redis Objects: Use Redis connection: 0.0.0.0:9001
                
                modbus.5
                2025-03-06 17:27:43.961	info	terminating
                
                modbus.5
                2025-03-06 17:27:43.476	info	Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                
                modbus.5
                2025-03-06 17:27:43.476	debug	Plugin sentry destroyed
                
                modbus.5
                2025-03-06 17:27:43.476	info	terminating
                
                modbus.5
                2025-03-06 17:27:43.460	debug	Closing client on purpose.
                
                modbus.5
                2025-03-06 17:27:43.459	info	Got terminate signal TERMINATE_YOURSELF
                
                wendy2702 1 Reply Last reply Reply Quote 0
                • Elektroniker86
                  Elektroniker86 @wendy2702 last edited by Elektroniker86

                  @wendy2702

                  Screenshot 2025-03-06 173115.png

                  Port stell ich um und probiere nochmal aus.

                  Mehr gibts nicht einzustellen bei dem adapter

                  1 Reply Last reply Reply Quote 0
                  • wendy2702
                    wendy2702 @Elektroniker86 last edited by

                    @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                    ERR_BUFFER_OUT_OF_BOUNDS]: Attempt to access memory outside buffer bounds

                    Das sieht für mich so aus als wenn die Antwort zu lang ist und der reservierte Buffer nicht reicht.

                    In deinem Link aus dem JSON steht für länge 0, hilft uns aber auch nicht weiter.

                    Software zum testen:
                    ModbusPoll
                    GmodbusMaster
                    RMMS (Radzio Modbus Master Simulator

                    Homoran Elektroniker86 2 Replies Last reply Reply Quote 0
                    • Homoran
                      Homoran Global Moderator Administrators @wendy2702 last edited by

                      @wendy2702 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                      und der reservierte Buffer nicht reicht.

                      @Elektroniker86
                      auch wenn (oder gerade weil) du nur ein Register haben willst, stell mal in den Grundeinstellungen die Anzahl gepollte Register auf einen niedrigen Wert.

                      @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                      beim Reiter Holding eingetragen

                      und Abfrage angehakt?

                      Elektroniker86 2 Replies Last reply Reply Quote 0
                      • Elektroniker86
                        Elektroniker86 @Homoran last edited by Elektroniker86

                        @homoran sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                        und Abfrage angehakt?

                        Ja, habe ich angehakt:

                        Screenshot 2025-03-07 095828.png

                        @homoran sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                        auch wenn (oder gerade weil) du nur ein Register haben willst, stell mal in den Grundeinstellungen die Anzahl gepollte Register auf einen niedrigen Wert.

                        Probiere ich aus.

                        1 Reply Last reply Reply Quote 0
                        • Elektroniker86
                          Elektroniker86 @Homoran last edited by

                          @homoran sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                          auch wenn (oder gerade weil) du nur ein Register haben willst, stell mal in den Grundeinstellungen die Anzahl gepollte Register auf einen niedrigen Wert.

                          Habe ich auch getestet habe die Werte auf die Hälfte eingestellt.

                          Screenshot 2025-03-07 100309.png

                          
                          modbus.5
                          2025-03-07 10:01:01.501	debug	Closing client on purpose.
                          
                          modbus.5
                          2025-03-07 10:01:00.499	debug	Cleaning up request fifo.
                          
                          modbus.5
                          2025-03-07 10:01:00.499	debug	Clearing timeout of the current request.
                          
                          modbus.5
                          2025-03-07 10:01:00.499	debug	Socket closed with error
                          
                          modbus.5
                          2025-03-07 10:01:00.491	info	Disconnected from slave 192.168.1.146
                          
                          modbus.5
                          2025-03-07 10:01:00.491	debug	Closing client on purpose.
                          
                          modbus.5
                          2025-03-07 10:01:00.441	warn	[DevID_1] Poll error count: 6 code: "App Timeout"
                          
                          modbus.5
                          2025-03-07 10:00:55.314	warn	Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                          
                          modbus.5
                          2025-03-07 10:00:55.241	debug	[DevID_1/holdingRegs] Poll address 4752 - 2 registers
                          
                          modbus.5
                          2025-03-07 10:00:55.241	debug	[DevID_1] Poll start ---------------------
                          
                          modbus.5
                          2025-03-07 10:00:54.189	warn	[DevID_1] Poll error count: 5 code: "App Timeout"
                          
                          modbus.5
                          2025-03-07 10:00:49.053	warn	Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                          
                          modbus.5
                          2025-03-07 10:00:48.988	debug	[DevID_1/holdingRegs] Poll address 4752 - 2 registers
                          
                          modbus.5
                          2025-03-07 10:00:48.988	debug	[DevID_1] Poll start ---------------------
                          
                          modbus.5
                          2025-03-07 10:00:47.938	warn	[DevID_1] Poll error count: 4 code: "App Timeout"
                          
                          modbus.5
                          2025-03-07 10:00:42.840	warn	Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                          
                          modbus.5
                          2025-03-07 10:00:42.737	debug	[DevID_1/holdingRegs] Poll address 4752 - 2 registers
                          
                          modbus.5
                          2025-03-07 10:00:42.737	debug	[DevID_1] Poll start ---------------------
                          
                          modbus.5
                          2025-03-07 10:00:41.686	warn	[DevID_1] Poll error count: 3 code: "App Timeout"
                          
                          modbus.5
                          2025-03-07 10:00:36.577	warn	Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                          
                          modbus.5
                          2025-03-07 10:00:36.485	debug	[DevID_1/holdingRegs] Poll address 4752 - 2 registers
                          
                          modbus.5
                          2025-03-07 10:00:36.485	debug	[DevID_1] Poll start ---------------------
                          
                          modbus.5
                          2025-03-07 10:00:35.434	warn	[DevID_1] Poll error count: 2 code: "App Timeout"
                          
                          modbus.5
                          2025-03-07 10:00:30.313	warn	Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                          
                          modbus.5
                          2025-03-07 10:00:30.233	debug	[DevID_1/holdingRegs] Poll address 4752 - 2 registers
                          
                          modbus.5
                          2025-03-07 10:00:30.233	debug	[DevID_1] Poll start ---------------------
                          
                          modbus.5
                          2025-03-07 10:00:29.182	warn	[DevID_1] Poll error count: 1 code: "App Timeout"
                          
                          modbus.5
                          2025-03-07 10:00:24.100	warn	Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                          
                          modbus.5
                          2025-03-07 10:00:23.981	debug	[DevID_1/holdingRegs] Poll address 4752 - 2 registers
                          
                          modbus.5
                          2025-03-07 10:00:23.981	debug	Initialization of scale factors done!
                          
                          modbus.5
                          2025-03-07 10:00:23.981	debug	[DevID_1] Poll start ---------------------
                          
                          modbus.5
                          2025-03-07 10:00:23.980	info	Connected to slave 192.168.1.146
                          
                          modbus.5
                          2025-03-07 10:00:23.886	debug	Add holdingRegisters.4752_Total_Battery_Voltage: {"_id":"holdingRegisters.4752_Total_Battery_Voltage","type":"state","common":{"name":"bat vol","role":"value","type":"number","read":true,"write":true,"def":0,"unit":"mV"},"native":{"regType":"holdingRegs","address":4752,"deviceId":1,"type":"uint32be","len":2,"offset":0,"factor":1,"poll":true}}
                          
                          modbus.5
                          2025-03-07 10:00:23.885	debug	Initialize Objects for holdingRegs: [{"_address":"4752","name":"Total Battery Voltage","description":"bat vol","unit":"mV","type":"uint32be","len":2,"factor":1,"offset":0,"formula":"","role":"value","room":"","poll":true,"wp":false,"cw":false,"isScale":false,"deviceId":1,"address":4752,"id":"holdingRegisters.4752_Total_Battery_Voltage"}]
                          
                          modbus.5
                          2025-03-07 10:00:23.885	debug	Initialize Objects for inputRegs: []
                          
                          modbus.5
                          2025-03-07 10:00:23.885	debug	Initialize Objects for coils: []
                          
                          modbus.5
                          2025-03-07 10:00:23.885	debug	Initialize Objects for disInputs: []
                          
                          modbus.5
                          2025-03-07 10:00:23.828	info	starting. Version 6.3.2 in /opt/iobroker/node_modules/iobroker.modbus, node: v20.18.3, js-controller: 7.0.6
                          
                          modbus.5
                          2025-03-07 10:00:23.711	debug	Plugin sentry Initialize Plugin (enabled=true)
                          
                          modbus.5
                          2025-03-07 10:00:19.818	info	terminating
                          
                          modbus.5
                          2025-03-07 10:00:19.332	info	Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                          
                          modbus.5
                          2025-03-07 10:00:19.332	debug	Plugin sentry destroyed
                          
                          modbus.5
                          2025-03-07 10:00:19.332	info	terminating
                          
                          modbus.5
                          2025-03-07 10:00:19.317	debug	Closing client on purpose.
                          
                          modbus.5
                          2025-03-07 10:00:19.316	info	Got terminate signal TERMINATE_YOURSELF
                          
                          modbus.5
                          2025-03-07 10:00:12.413	debug	Closing client on purpose.
                          
                          modbus.5
                          2025-03-07 10:00:11.412	debug	Cleaning up request fifo.
                          
                          modbus.5
                          2025-03-07 10:00:11.412	debug	Clearing timeout of the current request.
                          
                          modbus.5
                          2025-03-07 10:00:11.412	debug	Socket closed with error
                          
                          modbus.5
                          2025-03-07 10:00:11.404	info	Disconnected from slave 192.168.1.146
                          
                          modbus.5
                          2025-03-07 10:00:11.404	debug	Closing client on purpose.
                          
                          modbus.5
                          2025-03-07 10:00:11.353	warn	[DevID_1] Poll error count: 10 code: "App Timeout"
                          
                          modbus.5
                          2025-03-07 10:00:06.266	warn	Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                          
                          modbus.5
                          2025-03-07 10:00:06.153	debug	[DevID_1/holdingRegs] Poll address 4752 - 2 registers
                          
                          modbus.5
                          2025-03-07 10:00:06.153	debug	[DevID_1] Poll start ---------------------
                          
                          modbus.5
                          2025-03-07 10:00:06.153	info	Connected to slave 192.168.1.146
                          
                          modbus.5
                          2025-03-07 09:59:07.158	debug	Closing client on purpose.
                          
                          modbus.5
                          2025-03-07 09:59:06.158	debug	Cleaning up request fifo.
                          
                          modbus.5
                          2025-03-07 09:59:06.158	debug	Clearing timeout of the current request.
                          
                          modbus.5
                          2025-03-07 09:59:06.158	debug	Socket closed with error
                          
                          modbus.5
                          2025-03-07 09:59:06.151	info	Disconnected from slave 192.168.1.146
                          
                          modbus.5
                          2025-03-07 09:59:06.151	debug	Closing client on purpose.
                          
                          modbus.5
                          2025-03-07 09:59:06.100	warn	[DevID_1] Poll error count: 9 code: "App Timeout"
                          
                          modbus.5
                          2025-03-07 09:59:00.997	warn	Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                          
                          modbus.5
                          2025-03-07 09:59:00.901	debug	[DevID_1/holdingRegs] Poll address 4752 - 2 registers
                          
                          modbus.5
                          2025-03-07 09:59:00.900	debug	[DevID_1] Poll start ---------------------
                          
                          modbus.5
                          2025-03-07 09:59:00.900	info	Connected to slave 192.168.1.146
                          
                          Homoran 1 Reply Last reply Reply Quote 0
                          • Homoran
                            Homoran Global Moderator Administrators @Elektroniker86 last edited by Homoran

                            @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                            auf die Hälfte eingestellt.

                            bitte auf 1 oder 2 stellen
                            es gibt Geräte die sich sonst aufhängen.

                            Muss nicht die Ursache sein, würde ich gerne ausschließen

                            @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                            Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4

                            wo steht der Parameter denn?

                            Hier
                            Screenshot_20250307-100722_Firefox.jpg
                            steht 0, nicht 4

                            Elektroniker86 2 Replies Last reply Reply Quote 0
                            • Elektroniker86
                              Elektroniker86 @Homoran last edited by

                              @homoran

                              Screenshot 2025-03-07 101501.png

                              Screenshot 2025-03-07 101436.png

                              modbus.5
                              2025-03-07 10:16:18.537	debug	Closing client on purpose.
                              
                              modbus.5
                              2025-03-07 10:16:17.536	debug	Cleaning up request fifo.
                              
                              modbus.5
                              2025-03-07 10:16:17.536	debug	Clearing timeout of the current request.
                              
                              modbus.5
                              2025-03-07 10:16:17.536	debug	Socket closed with error
                              
                              modbus.5
                              2025-03-07 10:16:17.531	info	Disconnected from slave 192.168.1.146
                              
                              modbus.5
                              2025-03-07 10:16:17.531	debug	Closing client on purpose.
                              
                              modbus.5
                              2025-03-07 10:16:17.480	warn	[DevID_1] Poll error count: 6 code: "App Timeout"
                              
                              modbus.5
                              2025-03-07 10:16:12.369	warn	Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                              
                              modbus.5
                              2025-03-07 10:16:12.279	debug	[DevID_1/holdingRegs] Poll address 4752 - 2 registers
                              
                              modbus.5
                              2025-03-07 10:16:12.279	debug	[DevID_1] Poll start ---------------------
                              
                              modbus.5
                              2025-03-07 10:16:11.228	warn	[DevID_1] Poll error count: 5 code: "App Timeout"
                              
                              modbus.5
                              2025-03-07 10:16:06.105	warn	Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                              
                              modbus.5
                              2025-03-07 10:16:06.027	debug	[DevID_1/holdingRegs] Poll address 4752 - 2 registers
                              
                              modbus.5
                              2025-03-07 10:16:06.027	debug	[DevID_1] Poll start ---------------------
                              
                              modbus.5
                              2025-03-07 10:16:04.975	warn	[DevID_1] Poll error count: 4 code: "App Timeout"
                              
                              modbus.5
                              2025-03-07 10:15:59.843	warn	Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                              
                              modbus.5
                              2025-03-07 10:15:59.775	debug	[DevID_1/holdingRegs] Poll address 4752 - 2 registers
                              
                              modbus.5
                              2025-03-07 10:15:59.775	debug	[DevID_1] Poll start ---------------------
                              
                              modbus.5
                              2025-03-07 10:15:58.724	warn	[DevID_1] Poll error count: 3 code: "App Timeout"
                              
                              modbus.5
                              2025-03-07 10:15:53.629	warn	Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                              
                              modbus.5
                              2025-03-07 10:15:53.523	debug	[DevID_1/holdingRegs] Poll address 4752 - 2 registers
                              
                              modbus.5
                              2025-03-07 10:15:53.523	debug	[DevID_1] Poll start ---------------------
                              
                              modbus.5
                              2025-03-07 10:15:52.471	warn	[DevID_1] Poll error count: 2 code: "App Timeout"
                              
                              modbus.5
                              2025-03-07 10:15:47.365	warn	Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                              
                              modbus.5
                              2025-03-07 10:15:47.270	debug	[DevID_1/holdingRegs] Poll address 4752 - 2 registers
                              
                              modbus.5
                              2025-03-07 10:15:47.270	debug	[DevID_1] Poll start ---------------------
                              
                              modbus.5
                              2025-03-07 10:15:46.219	warn	[DevID_1] Poll error count: 1 code: "App Timeout"
                              
                              modbus.5
                              2025-03-07 10:15:41.103	warn	Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4
                              
                              modbus.5
                              2025-03-07 10:15:41.019	debug	[DevID_1/holdingRegs] Poll address 4752 - 2 registers
                              
                              modbus.5
                              2025-03-07 10:15:41.019	debug	Initialization of scale factors done!
                              
                              modbus.5
                              2025-03-07 10:15:41.018	debug	[DevID_1] Poll start ---------------------
                              
                              modbus.5
                              2025-03-07 10:15:41.018	info	Connected to slave 192.168.1.146
                              
                              modbus.5
                              2025-03-07 10:15:40.927	debug	Add holdingRegisters.4752_Total_Battery_Voltage: {"_id":"holdingRegisters.4752_Total_Battery_Voltage","type":"state","common":{"name":"bat vol","role":"value","type":"number","read":true,"write":true,"def":0,"unit":"mV"},"native":{"regType":"holdingRegs","address":4752,"deviceId":1,"type":"uint32be","len":2,"offset":4,"factor":1,"poll":true}}
                              
                              modbus.5
                              2025-03-07 10:15:40.927	debug	Initialize Objects for holdingRegs: [{"_address":"4752","name":"Total Battery Voltage","description":"bat vol","unit":"mV","type":"uint32be","len":2,"factor":1,"offset":4,"formula":"","role":"value","room":"","poll":true,"wp":false,"cw":false,"isScale":false,"deviceId":1,"address":4752,"id":"holdingRegisters.4752_Total_Battery_Voltage"}]
                              
                              modbus.5
                              2025-03-07 10:15:40.927	debug	Initialize Objects for inputRegs: []
                              
                              modbus.5
                              2025-03-07 10:15:40.927	debug	Initialize Objects for coils: []
                              
                              modbus.5
                              2025-03-07 10:15:40.927	debug	Initialize Objects for disInputs: []
                              
                              modbus.5
                              2025-03-07 10:15:40.874	info	starting. Version 6.3.2 in /opt/iobroker/node_modules/iobroker.modbus, node: v20.18.3, js-controller: 7.0.6
                              
                              modbus.5
                              2025-03-07 10:15:40.764	debug	Plugin sentry Initialize Plugin (enabled=true)
                              
                              modbus.5
                              2025-03-07 10:15:36.922	info	terminating
                              
                              modbus.5
                              2025-03-07 10:15:36.437	info	Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                              
                              modbus.5
                              2025-03-07 10:15:36.437	debug	Plugin sentry destroyed
                              
                              modbus.5
                              2025-03-07 10:15:36.437	info	terminating
                              
                              modbus.5
                              2025-03-07 10:15:36.422	debug	Closing client on purpose.
                              
                              modbus.5
                              2025-03-07 10:15:36.422	info	Got terminate signal TERMINATE_YOURSELF
                              

                              Sehr komisch alles, habe mit Modbus noch nie Probleme gehabt. Habe alle SMA Wechselrichter drin plus Energiezähler von EASTRoN und Heidelberg Ladestation die funktionieren super.

                              Homoran 1 Reply Last reply Reply Quote 0
                              • Elektroniker86
                                Elektroniker86 last edited by

                                Ich habe zum Test jetzt auch mal noch ein ELFIN RS485 Adapter probiert aber auch hier das selbe

                                1 Reply Last reply Reply Quote 0
                                • Homoran
                                  Homoran Global Moderator Administrators @Elektroniker86 last edited by Homoran

                                  @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                                                          2025-03-07 10:15:40.927	debug	Initialize Objects for holdingRegs: [{"_address":"4752","name":"Total Battery Voltage","description":"bat vol","unit":"mV","type":"uint32be","len":2,"factor":1,"offset":4,"formula":"","role":"value","room":"","poll":true,"wp":false,"cw":false,"isScale":false,"deviceId":1,"address":4752,"id":"holdingRegisters.4752_Total_Battery_Voltage"}]                                                                    
                                  

                                  wo kommt der offset 4 her?

                                  edit!
                                  hast du den in der Zwischenzeit eingestellt?
                                  Warum?

                                  Das ist im Moment der einzige Fehler

                                  1 Reply Last reply Reply Quote 0
                                  • Elektroniker86
                                    Elektroniker86 @Homoran last edited by

                                    @homoran sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                                    Hier

                                    steht 0, nicht 4

                                    Ich habe es so verstanden das ich den so einstellen soll
                                    Sorry

                                    Homoran 1 Reply Last reply Reply Quote 0
                                    • Homoran
                                      Homoran Global Moderator Administrators @Elektroniker86 last edited by Homoran

                                      @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                                      das ich den so einstellen soll

                                      nein!

                                      @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                                      2025-03-07 10:00:55.314 warn Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4

                                      Elektroniker86 1 Reply Last reply Reply Quote 0
                                      • Elektroniker86
                                        Elektroniker86 @Homoran last edited by

                                        @homoran

                                        Ich habe den ZLAN wieder angeschlossen und offset auf 0

                                        
                                        modbus.5
                                        2025-03-07 10:47:53.458	info	Disconnected from slave 192.168.1.123
                                        
                                        modbus.5
                                        2025-03-07 10:47:53.458	debug	Closing client on purpose.
                                        
                                        modbus.5
                                        2025-03-07 10:47:52.457	debug	Cleaning up request fifo.
                                        
                                        modbus.5
                                        2025-03-07 10:47:52.457	debug	Clearing timeout of the current request.
                                        
                                        modbus.5
                                        2025-03-07 10:47:52.457	debug	Socket closed with error
                                        
                                        modbus.5
                                        2025-03-07 10:47:52.457	warn	[DevID_1] Poll error count: 7 code: {"err":"timeout","timeout":5000}
                                        
                                        modbus.5
                                        2025-03-07 10:47:52.456	error	Client in error state.
                                        
                                        modbus.5
                                        2025-03-07 10:47:52.456	error	Request timed out.
                                        
                                        modbus.5
                                        2025-03-07 10:47:52.456	warn	Error: undefined
                                        
                                        modbus.5
                                        2025-03-07 10:47:47.456	debug	[DevID_1/holdingRegs] Poll address 4752 - 2 registers
                                        
                                        modbus.5
                                        2025-03-07 10:47:47.456	debug	[DevID_1] Poll start ---------------------
                                        
                                        modbus.5
                                        2025-03-07 10:47:47.456	info	Connected to slave 192.168.1.123
                                        
                                        Homoran 1 Reply Last reply Reply Quote 0
                                        • Homoran
                                          Homoran Global Moderator Administrators @Elektroniker86 last edited by

                                          @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                                                                  2025-03-07 10:47:52.456	warn	Error: undefined
                                          

                                          macht keinen Spaß 😉

                                          @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                                          den ZLAN

                                          ist was?
                                          gibt es da was einzustellen, was nicht zu den Adapter Einstellungen oder WR Einstellungen passt?

                                          Elektroniker86 1 Reply Last reply Reply Quote 0
                                          • Elektroniker86
                                            Elektroniker86 @wendy2702 last edited by Elektroniker86

                                            @wendy2702 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                                            RMMS (Radzio Modbus Master Simulator

                                            Den habe ich mal runtergeladen, aber da passiert überhaupt nichts habe die verbindung über den usb und den tcp Adapter probiert unten bei TX RX passiert nichts.

                                            Mit dem Programm vom JK BMS klappt die Verbindung mit dem usb Adapter einwandfrei.

                                            Screenshot 2025-03-07 105225.png

                                            Homoran 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            957
                                            Online

                                            31.7k
                                            Users

                                            79.7k
                                            Topics

                                            1.3m
                                            Posts

                                            5
                                            92
                                            3056
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo