    JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.

    This topic has been deleted. Only users with topic management privileges can see it.
    • Homoran
      Homoran Global Moderator Administrators @Elektroniker86 last edited by Homoran

      @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                              2025-03-07 10:15:40.927	debug	Initialize Objects for holdingRegs: [{"_address":"4752","name":"Total Battery Voltage","description":"bat vol","unit":"mV","type":"uint32be","len":2,"factor":1,"offset":4,"formula":"","role":"value","room":"","poll":true,"wp":false,"cw":false,"isScale":false,"deviceId":1,"address":4752,"id":"holdingRegisters.4752_Total_Battery_Voltage"}]                                                                    
      

      wo kommt der offset 4 her?

      edit!
      hast du den in der Zwischenzeit eingestellt?
      Warum?

      Das ist im Moment der einzige Fehler

      1 Reply Last reply Reply Quote 0
      • Elektroniker86
        Elektroniker86 @Homoran last edited by

        @homoran sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

        Hier

        steht 0, nicht 4

        Ich habe es so verstanden das ich den so einstellen soll
        Sorry

        Homoran 1 Reply Last reply Reply Quote 0
        • Homoran
          Homoran Global Moderator Administrators @Elektroniker86 last edited by Homoran

          @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

          das ich den so einstellen soll

          nein!

          @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

          2025-03-07 10:00:55.314 warn Error in handler for 3: RangeError [ERR_OUT_OF_RANGE]: The value of "offset" is out of range. It must be >= 0 and <= 3. Received 4

          Elektroniker86 1 Reply Last reply Reply Quote 0
          • Elektroniker86
            Elektroniker86 @Homoran last edited by

            @homoran

            Ich habe den ZLAN wieder angeschlossen und offset auf 0

            
            modbus.5
            2025-03-07 10:47:53.458	info	Disconnected from slave 192.168.1.123
            
            modbus.5
            2025-03-07 10:47:53.458	debug	Closing client on purpose.
            
            modbus.5
            2025-03-07 10:47:52.457	debug	Cleaning up request fifo.
            
            modbus.5
            2025-03-07 10:47:52.457	debug	Clearing timeout of the current request.
            
            modbus.5
            2025-03-07 10:47:52.457	debug	Socket closed with error
            
            modbus.5
            2025-03-07 10:47:52.457	warn	[DevID_1] Poll error count: 7 code: {"err":"timeout","timeout":5000}
            
            modbus.5
            2025-03-07 10:47:52.456	error	Client in error state.
            
            modbus.5
            2025-03-07 10:47:52.456	error	Request timed out.
            
            modbus.5
            2025-03-07 10:47:52.456	warn	Error: undefined
            
            modbus.5
            2025-03-07 10:47:47.456	debug	[DevID_1/holdingRegs] Poll address 4752 - 2 registers
            
            modbus.5
            2025-03-07 10:47:47.456	debug	[DevID_1] Poll start ---------------------
            
            modbus.5
            2025-03-07 10:47:47.456	info	Connected to slave 192.168.1.123
            
            Homoran 1 Reply Last reply Reply Quote 0
            • Homoran
              Homoran Global Moderator Administrators @Elektroniker86 last edited by

              @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                                      2025-03-07 10:47:52.456	warn	Error: undefined
              

              macht keinen Spaß 😉

              @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

              den ZLAN

              ist was?
              gibt es da was einzustellen, was nicht zu den Adapter Einstellungen oder WR Einstellungen passt?

              Elektroniker86 1 Reply Last reply Reply Quote 0
              • Elektroniker86
                Elektroniker86 @wendy2702 last edited by Elektroniker86

                @wendy2702 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                RMMS (Radzio Modbus Master Simulator

                Den habe ich mal runtergeladen, aber da passiert überhaupt nichts habe die verbindung über den usb und den tcp Adapter probiert unten bei TX RX passiert nichts.

                Mit dem Programm vom JK BMS klappt die Verbindung mit dem usb Adapter einwandfrei.

                Screenshot 2025-03-07 105225.png

                Homoran 1 Reply Last reply Reply Quote 0
                • Homoran
                  Homoran Global Moderator Administrators @Elektroniker86 last edited by

                  @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                  mit dem usb Adapter

                  den sollte man immer nehmen, wenn möglich.
                  Einen TCP2RS485 Konverter zwischenzuschalten bringt immer weitere Fehlermöglichkeiten mit sich

                  Elektroniker86 1 Reply Last reply Reply Quote 0
                  • Elektroniker86
                    Elektroniker86 @Homoran last edited by

                    @homoran sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                    den ZLAN

                    Screenshot 2025-03-07 105518.png

                    Das ist der ZLAN RS485 Adapter hier im Screenshot alle Einstellungen.

                    Homoran 1 Reply Last reply Reply Quote 0
                    • Elektroniker86
                      Elektroniker86 @Homoran last edited by

                      @homoran sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                      Einen TCP2RS485 Konverter zwischenzuschalten bringt immer weitere Fehlermöglichkeiten mit sich

                      Ja, habe aber keine andere Möglichkeit da die Technik der PV Batterie in der Garage ist

                      Elektroniker86 1 Reply Last reply Reply Quote 0
                      • Elektroniker86
                        Elektroniker86 @Elektroniker86 last edited by

                        @elektroniker86

                        Kann es sein das etwas mit der Adresse nicht stimmt ? Sollte man mal eine andere her nehmen?
                        Habe auch nicht verstanden warum wir jetzt die Adresse um die Spannung abzufragen in holding eingetragen haben, dachte holding ist nur um Werte zu setzen?

                        Homoran 1 Reply Last reply Reply Quote 0
                        • Homoran
                          Homoran Global Moderator Administrators @Elektroniker86 last edited by

                          @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                          @homoran sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                          den ZLAN

                          Screenshot 2025-03-07 105518.png

                          Das ist der ZLAN RS485 Adapter hier im Screenshot alle Einstellungen.

                          Damit kenne ich ich gar nicht aus, aber
                          Screenshot_20250307-110153_Firefox.jpg

                          Elektroniker86 1 Reply Last reply Reply Quote 0
                          • Elektroniker86
                            Elektroniker86 @Homoran last edited by

                            @homoran sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                            Damit kenne ich ich gar nicht aus, aber

                            Ich habe das als DNS interpretiert falls man den Adapter von aussen erreichen möchte? Habe allerdings auch schon die IP vom ioBroker eingetragen gehabt.

                            Konnte kein unterschied feststellen...

                            Homoran 1 Reply Last reply Reply Quote 0
                            • Homoran
                              Homoran Global Moderator Administrators @Elektroniker86 last edited by

                              @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                              warum wir jetzt die Adresse um die Spannung abzufragen in holding eingetragen haben

                              weil es so in deiner Anleitung steht.

                              @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                              dachte holding ist nur um Werte zu setzen?

                              da halten sich aber leider viele Hersteller nicht dran

                              Elektroniker86 1 Reply Last reply Reply Quote 0
                              • Homoran
                                Homoran Global Moderator Administrators @Elektroniker86 last edited by

                                @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                                Habe allerdings auch schon die IP vom ioBroker eingetragen gehabt.

                                was stand dann im log?

                                1 Reply Last reply Reply Quote 0
                                • Elektroniker86
                                  Elektroniker86 @Homoran last edited by

                                  @homoran sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                                  dachte holding ist nur um Werte zu setzen?

                                  Alles klar, verstanden

                                  hier nochmal der log mit eingetragener io ip bei destination:

                                  
                                  modbus.5
                                  2025-03-07 11:06:47.158	info	Disconnected from slave 192.168.1.123
                                  
                                  modbus.5
                                  2025-03-07 11:06:47.157	debug	Closing client on purpose.
                                  
                                  modbus.5
                                  2025-03-07 11:06:46.157	debug	Cleaning up request fifo.
                                  
                                  modbus.5
                                  2025-03-07 11:06:46.157	debug	Clearing timeout of the current request.
                                  
                                  modbus.5
                                  2025-03-07 11:06:46.157	debug	Socket closed with error
                                  
                                  modbus.5
                                  2025-03-07 11:06:46.156	warn	[DevID_1] Poll error count: 2 code: {"err":"timeout","timeout":5000}
                                  
                                  modbus.5
                                  2025-03-07 11:06:46.156	error	Client in error state.
                                  
                                  modbus.5
                                  2025-03-07 11:06:46.156	error	Request timed out.
                                  
                                  modbus.5
                                  2025-03-07 11:06:46.156	warn	Error: undefined
                                  
                                  modbus.5
                                  2025-03-07 11:06:41.156	debug	[DevID_1/holdingRegs] Poll address 4752 - 2 registers
                                  
                                  modbus.5
                                  2025-03-07 11:06:41.155	debug	[DevID_1] Poll start ---------------------
                                  
                                  modbus.5
                                  2025-03-07 11:06:40.327	warn	Error in handler for 3: RangeError [ERR_BUFFER_OUT_OF_BOUNDS]: Attempt to access memory outside buffer bounds
                                  
                                  modbus.5
                                  2025-03-07 11:06:40.327	warn	Error in handler for 3: RangeError [ERR_BUFFER_OUT_OF_BOUNDS]: Attempt to access memory outside buffer bounds
                                  
                                  modbus.5
                                  2025-03-07 11:06:40.104	warn	[DevID_1] Poll error count: 1 code: "ReadHoldingRegisters: Invalid FC 13"
                                  
                                  modbus.5
                                  2025-03-07 11:06:40.104	warn	Error in handler for 3: RangeError [ERR_BUFFER_OUT_OF_BOUNDS]: Attempt to access memory outside buffer bounds
                                  
                                  modbus.5
                                  2025-03-07 11:06:40.104	warn	Error in handler for 3: RangeError [ERR_BUFFER_OUT_OF_BOUNDS]: Attempt to access memory outside buffer bounds
                                  
                                  modbus.5
                                  2025-03-07 11:06:40.104	warn	Error in handler for 3: RangeError [ERR_BUFFER_OUT_OF_BOUNDS]: Attempt to access memory outside buffer bounds
                                  
                                  modbus.5
                                  2025-03-07 11:06:40.104	warn	Error in handler for 3: RangeError [ERR_BUFFER_OUT_OF_BOUNDS]: Attempt to access memory outside buffer bounds
                                  
                                  modbus.5
                                  2025-03-07 11:06:40.104	warn	Error in handler for 3: RangeError [ERR_BUFFER_OUT_OF_BOUNDS]: Attempt to access memory outside buffer bounds
                                  
                                  modbus.5
                                  2025-03-07 11:06:40.103	warn	Error in handler for 3: RangeError [ERR_BUFFER_OUT_OF_BOUNDS]: Attempt to access memory outside buffer bounds
                                  
                                  modbus.5
                                  2025-03-07 11:06:40.103	warn	Error in handler for 3: RangeError [ERR_BUFFER_OUT_OF_BOUNDS]: Attempt to access memory outside buffer bounds
                                  
                                  modbus.5
                                  2025-03-07 11:06:40.103	warn	Error in handler for 3: RangeError [ERR_BUFFER_OUT_OF_BOUNDS]: Attempt to access memory outside buffer bounds
                                  
                                  modbus.5
                                  2025-03-07 11:06:40.103	warn	Error in handler for 3: RangeError [ERR_BUFFER_OUT_OF_BOUNDS]: Attempt to access memory outside buffer bounds
                                  
                                  modbus.5
                                  2025-03-07 11:06:39.740	debug	[DevID_1/holdingRegs] Poll address 4752 - 2 registers
                                  
                                  modbus.5
                                  2025-03-07 11:06:39.740	debug	Initialization of scale factors done!
                                  
                                  modbus.5
                                  2025-03-07 11:06:39.739	debug	[DevID_1] Poll start ---------------------
                                  
                                  modbus.5
                                  2025-03-07 11:06:39.739	info	Connected to slave 192.168.1.123
                                  
                                  Homoran 1 Reply Last reply Reply Quote 0
                                  • Homoran
                                    Homoran Global Moderator Administrators @Elektroniker86 last edited by

                                    @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                                    Invalid FC 13

                                    ich hab keine Ahnung wo der herkommt
                                    Screenshot_20250307-111710_Firefox.jpg
                                    es gibt anscheinend wirklich keinen FC13

                                    auch der buffer error ist wieder da

                                    Elektroniker86 1 Reply Last reply Reply Quote 0
                                    • Elektroniker86
                                      Elektroniker86 @Homoran last edited by

                                      @homoran

                                      Sehr kurios, ich habe jetzt noch den Modbus Poll Runtergeladen. Kennst du dich mit dem Programm aus?

                                      Ich bekomme nicht mal eine Verbindung mit dem USB dongle hin......

                                      Screenshot 2025-03-07 112108.png Screenshot 2025-03-07 112015.png Screenshot 2025-03-07 111939.png

                                      Homoran 1 Reply Last reply Reply Quote 0
                                      • Homoran
                                        Homoran Global Moderator Administrators @Elektroniker86 last edited by

                                        @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                                        Kennst du dich mit dem Programm aus?

                                        nein.

                                        Bei mir ging es bisher mit allem out of the Box. Hab kein externes Programm gebraucht

                                        @elektroniker86 sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                                        Ich bekomme nicht mal eine Verbindung mit dem USB dongle hin......

                                        dann starte mal den WR neu

                                        Elektroniker86 1 Reply Last reply Reply Quote 0
                                        • Elektroniker86
                                          Elektroniker86 last edited by

                                          Am gleichen Laptop mit dem selben USB Dongle im JK Programm direkt eine Verbindung

                                          Screenshot 2025-03-07 112441.png

                                          Hilft das was? Ne Art Konsole wo die Bus Nachrichten reinkommen?

                                          Screenshot 2025-03-07 112642.png

                                          1 Reply Last reply Reply Quote 0
                                          • Elektroniker86
                                            Elektroniker86 @Homoran last edited by

                                            @homoran sagte in JK BMS mit Modbus Adapter über RS485 zu TCP einbinden.:

                                            dann starte mal den WR neu

                                            Der Wechselrichter Kommuniziert ja mit dem jk BMS über CAN..... Denke nicht das es daran liegt aber könnte das Kabel vom SI mal abstöpseln .....

                                            Ich möchte die Batteriewerte vom BMS auslesen da ich diese Werte nicht über den Sunny Island bekomme. Der Sunny liefert mir über Modbus nur den SOC und Lade bzw. Entladeleistung........

                                            Das JK Kommuniziert untereinander ( mehrere Batteriepacks) über Modbus

                                            Homoran 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            495
                                            Online

                                            31.7k
                                            Users

                                            79.7k
                                            Topics

                                            1.3m
                                            Posts

                                            5
                                            92
                                            3057
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo