    Tester Zigbee Adapter 3.x gesucht

    This topic has been deleted. Only users with topic management privileges can see it.
    • M
      MeisterQ 0 last edited by

      @Asgothian Bekommt man die Version schon aus dem Latest? Weil da wird sie mir nicht angezeigt, oder muss ich sie über die Github Katze Installieren?

      Asgothian 1 Reply Last reply Reply Quote 0
      • Asgothian
        Asgothian Developer @MeisterQ 0 last edited by Asgothian

        @meisterq-0 die version ist im Latest. (sollte sie zumindest sein)

        A.

        M L 2 Replies Last reply Reply Quote 0
        • M
          MeisterQ 0 @Asgothian last edited by

          @asgothian Komisch. Wird mir nicht Angezeigt.
          e0905dad-1578-464b-a3a5-47a6da1e52c4-grafik.png

          1 Reply Last reply Reply Quote 0
          • R
            Rushmed Most Active last edited by

            Hallo,

            was bedeuten auf dem Hardware Tab die Warnung und der Error?
            Muss ich hier aktiv werden?
            3a47e9b0-2444-4dc8-8adc-fee5f38cef9a-grafik.png

            Asgothian 1 Reply Last reply Reply Quote 0
            • Asgothian
              Asgothian Developer @Rushmed last edited by

              @rushmed sagte in Tester Zigbee Adapter 3.x gesucht:

              Hallo,

              was bedeuten auf dem Hardware Tab die Warnung und der Error?
              Muss ich hier aktiv werden?
              3a47e9b0-2444-4dc8-8adc-fee5f38cef9a-grafik.png

              Hast du die Doku auf Github dazu gelesen ? Da steht es drin.

              Das X bedeutet das der Transport Key nicht mit dem übereinstimmt der im Backup der Einstellungen steht.
              Der grüne Haken bedeutet das der Kanal mit dem überein stimmt der im Backup steht
              das gelbe Dreieck warnt das es ein ungünstiger Kanal ist (nicht teil der ZLL Kanäle, so das ggf. einzelne Geräte bei Dir nicht gehen

              Du kannst durch einlesen des Backup schauen ob das rote X weg geht - da ist noch ein Fehler drin, da aktuell gross/kleinschreibung noch einen Unterschied macht - das kommt noch weg.

              A.
              TLDR: Nein.

              R 1 Reply Last reply Reply Quote 1
              • R
                Rushmed Most Active @Asgothian last edited by

                @asgothian sagte in Tester Zigbee Adapter 3.x gesucht:

                Du kannst durch einlesen des Backup schauen ob das rote X weg geht - da ist noch ein Fehler drin, da aktuell gross/kleinschreibung noch einen Unterschied macht - das kommt noch weg.

                Hat geklappt, danke.

                1 Reply Last reply Reply Quote 0
                • B
                  BigMike71 last edited by BigMike71

                  Habe heute von 1.10.4 direkt auf die 3.0 upgedatet!
                  Nachdem ich meine ca. 20 Aqara Wandschalter in meinen Skripten an die neuen Datenpunkte angepasst habe und vorher ein readNvBackup durchgeführt habe läuft bisher alles problemlos! 👍

                  Allerdings bekomme ich wenn ich auf den Zigbee-Tab wechsel jedes Mal eine Warnung:

                  2025-04-11 15:52:31.145 - warn: zigbee.0 (1118465) readNvBackup called
                  2025-04-11 15:52:31.149 - warn: zigbee.0 (1118465) readNvBackup returns {"channel":11,"precfgkey":"b2090507090c0d0f00020406080b0c0d","extPanID":"0123456799abcdef","panID":3369}
                  

                  kann man das noch abschalten?

                  S 1 Reply Last reply Reply Quote 0
                  • S
                    Shadowhunter23 @BigMike71 last edited by Shadowhunter23

                    @bigmike71

                    ~8 Beiträge zuvor:
                    https://forum.iobroker.net/topic/80644/tester-zigbee-adapter-3-x-gesucht/8?_=1744382131667

                    1 Reply Last reply Reply Quote 0
                    • Fabio
                      Fabio @Asgothian last edited by Fabio

                      @asgothian bin jetzt auch auf die 3.0 hoch bis jetzt keine Probleme

                      ausser diese Warn Meldungen

                      zigbee.0
                      2025-04-15 15:17:06.934	warn	readNvBackup returns {"channel":11,"precfgkey":"01030507090b0d0f00020406080a0c0d","extPanID":"fecad609004b1200","panID":6754}
                      
                      zigbee.0
                      2025-04-15 15:17:06.929	warn	readNvBackup called
                      

                      aber da hast du ja schon zu geantwortet. 😉

                      Vielen Dank für deine Mühen
                      Herzliche Grüße aus Köln
                      Fabio

                      1 Reply Last reply Reply Quote 0
                      • ste_glei
                        ste_glei last edited by

                        @Asgothian
                        Bin jetzt seit ein paar Tagen auf 3.0 und es läuft ohne Probleme.

                        gefühlt stabiler als die Vorgänger.

                        Vielen Dank für deinen Einsatz

                        1 Reply Last reply Reply Quote 0
                        • L
                          locito09 @Asgothian last edited by

                          @asgothian
                          Bei mir läuft die 3.0 auch sehr stabil, hab aber ab und zuGeräte die die Verbindung verlieren 2 x Flower verlieren immer wieder die Verbindung und ich muss sie nochmals anlernen und auch verschiedene Hue Lampe muss ich kurz ausschalten und neu verbinden

                          1 Reply Last reply Reply Quote 0
                          • Fabio
                            Fabio @Asgothian last edited by Fabio

                            @asgothian das passierte jetzt schon 2 mal nachdem ich die 3.0 nutze.

                            
                            zigbee.0
                            2025-04-17 10:45:44.803	info	Starting Zigbee-Herdsman
                            
                            zigbee.0
                            2025-04-17 10:45:44.802	info	Installed Version: iobroker.zigbee@3.0.0 (Converters 23.27.0 Herdsman 3.5.1)
                            
                            zigbee.0
                            2025-04-17 10:45:44.790	info	Starting Adapter npm ...
                            
                            zigbee.0
                            2025-04-17 10:45:44.790	info	--- creating device debug ---
                            
                            zigbee.0
                            2025-04-17 10:45:44.789	info	delete old Backup files. keep only last 10
                            
                            zigbee.0
                            2025-04-17 10:45:44.770	info	--> transmitPower :
                            
                            zigbee.0
                            2025-04-17 10:45:44.767	info	init localConfig
                            
                            zigbee.0
                            2025-04-17 10:45:44.766	info	Adapter ready - starting subsystems. Adapter is running in info mode.
                            
                            zigbee.0
                            2025-04-17 10:45:44.752	info	starting. Version 3.0.0 in /opt/iobroker/node_modules/iobroker.zigbee, node: v20.19.0, js-controller: 7.0.6
                            
                            host.nuc
                            2025-04-17 10:45:43.990	info	instance system.adapter.zigbee.0 in version "3.0.0" started with pid 2762
                            
                            host.nuc
                            2025-04-17 10:45:13.538	info	Restart adapter system.adapter.zigbee.0 because enabled
                            
                            host.nuc
                            2025-04-17 10:45:13.538	error	instance system.adapter.zigbee.0 terminated with code 6 (UNCAUGHT_EXCEPTION)
                            
                            host.nuc
                            2025-04-17 10:45:13.538	error	Caught by controller[1]: at processTicksAndRejections (node:internal/process/task_queues:95:5)
                            
                            host.nuc
                            2025-04-17 10:45:13.538	error	Caught by controller[1]: at Controller.backup (/opt/iobroker/node_modules/zigbee-herdsman/src/controller/controller.ts:382:47)
                            
                            host.nuc
                            2025-04-17 10:45:13.538	error	Caught by controller[1]: at ZStackAdapter.backup (/opt/iobroker/node_modules/zigbee-herdsman/src/adapter/z-stack/adapter/zStackAdapter.ts:908:49)
                            
                            host.nuc
                            2025-04-17 10:45:13.538	error	Caught by controller[1]: at AdapterBackup.createBackup (/opt/iobroker/node_modules/zigbee-herdsman/src/adapter/z-stack/adapter/adapter-backup.ts:65:48)
                            
                            host.nuc
                            2025-04-17 10:45:13.538	error	Caught by controller[1]: at AdapterBackup.getAdapterVersion (/opt/iobroker/node_modules/zigbee-herdsman/src/adapter/z-stack/adapter/adapter-backup.ts:446:48)
                            
                            host.nuc
                            2025-04-17 10:45:13.538	error	Caught by controller[1]: at Znp.requestWithReply (/opt/iobroker/node_modules/zigbee-herdsman/src/adapter/z-stack/znp/znp.ts:224:34)
                            
                            host.nuc
                            2025-04-17 10:45:13.538	error	Caught by controller[1]: at Znp.request (/opt/iobroker/node_modules/zigbee-herdsman/src/adapter/z-stack/znp/znp.ts:240:19)
                            
                            host.nuc
                            2025-04-17 10:45:13.538	error	Caught by controller[1]: Error: Cannot request when znp has not been initialized yet
                            
                            host.nuc
                            2025-04-17 10:45:13.537	error	Caught by controller[1]: This error originated either by throwing inside of an async function without a catch block, or by rejecting a promise which was not handled with .catch(). The promise rejected with the reason:
                            
                            zigbee.0
                            2025-04-17 10:45:13.453	info	terminating
                            
                            zigbee.0
                            2025-04-17 10:45:13.273	info	Closing Zigbee network, 0 seconds remaining
                            
                            zigbee.0
                            2025-04-17 10:45:12.950	warn	Terminated (UNCAUGHT_EXCEPTION): Without reason
                            
                            zigbee.0
                            2025-04-17 10:45:12.950	info	terminating
                            
                            zigbee.0
                            2025-04-17 10:45:12.950	info	Saved local configuration data
                            
                            zigbee.0
                            2025-04-17 10:45:12.950	info	local config saved
                            
                            zigbee.0
                            2025-04-17 10:45:12.950	info	cleaned everything up...
                            
                            zigbee.0
                            2025-04-17 10:45:12.943	error	Cannot request when znp has not been initialized yet
                            
                            zigbee.0
                            2025-04-17 10:45:12.943	error	Error: Cannot request when znp has not been initialized yet at Znp.request (/opt/iobroker/node_modules/zigbee-herdsman/src/adapter/z-stack/znp/znp.ts:240:19) at Znp.requestWithReply (/opt/iobroker/node_modules/zigbee-herdsman/src/adapter/z-stack/znp/znp.ts:224:34) at AdapterBackup.getAdapterVersion (/opt/iobroker/node_modules/zigbee-herdsman/src/adapter/z-stack/adapter/adapter-backup.ts:446:48) at AdapterBackup.createBackup (/opt/iobroker/node_modules/zigbee-herdsman/src/adapter/z-stack/adapter/adapter-backup.ts:65:48) at ZStackAdapter.backup (/opt/iobroker/node_modules/zigbee-herdsman/src/adapter/z-stack/adapter/zStackAdapter.ts:908:49) at Controller.backup (/opt/iobroker/node_modules/zigbee-herdsman/src/controller/controller.ts:382:47) at processTicksAndRejections (node:internal/process/task_queues:95:5)
                            
                            zigbee.0
                            2025-04-17 10:45:12.933	error	unhandled promise rejection: Cannot request when znp has not been initialized yet
                            
                            zigbee.0
                            2025-04-17 10:45:12.933	error	Unhandled promise rejection. This error originated either by throwing inside of an async function without a catch block, or by rejecting a promise which was not handled with .catch().
                            

                            Hertliche Grüße aus Köln
                            Fabio
                            unhandled promise rejection.txt

                            Asgothian 1 Reply Last reply Reply Quote 0
                            • Asgothian
                              Asgothian Developer @Fabio last edited by

                              @fabio sagte in Tester Zigbee Adapter 3.x gesucht:

                              @asgothian das passierte jetzt schon 2 mal nachdem ich die 3.0 nutze.

                              Müssen wir beobachten. Passiert das immer nach längerer Laufzeit oder beim Start ?

                              Hintergrund: ZNP not initialized deutet darauf hin das versucht wird Kommunikation mit einem Zigbee-Gerät zu initiieren bevor der Herdsman sauber läuft.

                              A.

                              L 1 Reply Last reply Reply Quote 0
                              • Fabio
                                Fabio last edited by

                                @asgothian das passiert im laufenden Betrieb ohne mein dazutun zu unterschiedlichen Zeiten und auch erst seit der v 3.0.

                                Herzliche Grüße
                                Fabio

                                Asgothian 1 Reply Last reply Reply Quote 0
                                • L
                                  locito09 @Asgothian last edited by locito09

                                  @asgothian
                                  Habe bei den Flower sensor gemerkt das die Geräte die einwandfrei funktionieren der Status auf configured:false steht
                                  und die die nicht funktionieren steht der Status auf configured:true. Auch wen ich einen neuen Sensor anlerne steht der Status auf configured:True und Funktioniert nicht. Was kann das Problem sein?

                                  Screenshot 2025-04-17 113303.png Screenshot 2025-04-17 113225.png

                                  Asgothian 1 Reply Last reply Reply Quote 0
                                  • Asgothian
                                    Asgothian Developer @Fabio last edited by

                                    @fabio Kannst schauen was an Log Meldungen vor dem Fehler kommt ? Anscheinend startet der Adapter anstandslos neu - trotzdem ist die frage was er macht wenn der Fehler auftritt.

                                    A.

                                    Fabio 1 Reply Last reply Reply Quote 0
                                    • Asgothian
                                      Asgothian Developer @locito09 last edited by Asgothian

                                      @locito09 ändert sich daran etwas wenn du versuchst die nicht funktionierenden Geräte neu zu konfigurieren ?
                                      Auffällig ist auch das die Firmware unterschiedlich alt ist.

                                      A.

                                      L 1 Reply Last reply Reply Quote 0
                                      • L
                                        locito09 @Asgothian last edited by locito09

                                        @asgothian
                                        ja das habe ich auch schon bemerkt, ich habe insgesammt 10 stk und nur 1 davon hat eine ältere Firmware, aber Danke für den Hinweis. Habe alle 4 stk die nicht funktionieren neu Konfiguriert, jetzt sind die wieder online, werde die weiterhin beobachten. Das erneute Konmfigurieren wurde zwar im LOG mit einen Timeout Quittiert , die Geräte sind aber jetzt wieder Online und haben einen wert gesendet.

                                        
                                        zigbee.0
                                        2025-04-17 11:47:29.424	info	Timeout trying to configure 0x00124b002260a134 DIYRuZ_Flower (starting CoM).
                                        
                                        zigbee.0
                                        2025-04-17 11:47:19.411	info	Configuring 0x00124b002260a134 DIYRuZ_Flower
                                        
                                        zigbee.0
                                        2025-04-17 11:47:10.025	info	Timeout trying to configure 0x00124b0022607918 DIYRuZ_Flower (starting CoM).
                                        
                                        zigbee.0
                                        2025-04-17 11:47:00.897	info	Closing Zigbee network, 1 seconds remaining
                                        
                                        zigbee.0
                                        2025-04-17 11:47:00.011	info	Configuring 0x00124b0022607918 DIYRuZ_Flower
                                        
                                        zigbee.0
                                        2025-04-17 11:46:40.515	info	Timeout trying to configure 0x00124b00226296fc DIYRuZ_Flower (starting CoM).
                                        
                                        zigbee.0
                                        2025-04-17 11:46:30.499	info	Configuring 0x00124b00226296fc DIYRuZ_Flower
                                        
                                        Asgothian 1 Reply Last reply Reply Quote 0
                                        • Asgothian
                                          Asgothian Developer @locito09 last edited by Asgothian

                                          @locito09 sagte in Tester Zigbee Adapter 3.x gesucht:

                                          @asgothian
                                          ja das habe ich auch schon bemerkt, ich habe insgesammt 10 stk und nur 1 davon hat eine ältere Firmware, aber Danke für den Hinweis. Habe alle 4 stk die nicht funktionieren neu Konfiguriert, jetzt sind die wieder online, werde die weiterhin beobachten. Das erneute Konmfigurieren wurde zwar im LOG mit einen Timeout Quittiert , die Geräte sind aber jetzt wieder Online und haben einen wert gesendet.

                                          ich gehe davon aus das die ein 'configure_on_message' bekommen haben und deswegen jetzt wieder gehen

                                          1 Reply Last reply Reply Quote 0
                                          • Fabio
                                            Fabio @Asgothian last edited by

                                            @asgothian okay, ich werde beim nächsten mal drauf achten. 👍
                                            Jedes Mal innerhalb vom Sekunden neu gestartet und alles verbunden.👌

                                            Grüße
                                            Fabio

                                            Fabio 1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            931
                                            Online

                                            31.7k
                                            Users

                                            79.7k
                                            Topics

                                            1.3m
                                            Posts

                                            zigbee zigbee adapter
                                            20
                                            132
                                            6272
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo