      @fernetmenta
      Aber das würde jetzt nicht das Problem lösen, dass der PV Ertrag erst verzögert steigt, wenn der in der Batterie gespeicherte Strom verbraucht wird (und somit ich heute schon vor Sonnenaufgang PV Ertrag hatte, weil der Speicher erst heutge morgen um 4 leer war). Oder hab ich bei der Formel gerade einen Denkfehler?

      FernetMenta 1 Reply Last reply Reply Quote 0
      • FernetMenta
        FernetMenta @TomRacoon last edited by FernetMenta

        @tomracoon der Strom, den du heute morgen noch aus der Batterie verbraucht hast, wird durch Statistic:EnergyHomeBat vom Yield abgezogen. Dadurch ist der PV-Ertrag, wie im Portal, vor Sonnenaufgang 0.

        Der Strom, den du im Yield erst mal nicht siehst, weil er in die Batterie geht, wird durch Statistic:EnergyChargePv addiert.

        FernetMenta 1 Reply Last reply Reply Quote 0
        • FernetMenta
          FernetMenta @FernetMenta last edited by FernetMenta

          Mir persönich ist Yield, wie vom Plenticore geliefert, lieber, weil das genau das ist, was man vom Gesamtsystem bekommt. Es ist halt so, dass durch laden der Batterie ein Verlust entsteht.
          Kostal, auf der anderen Seite, stellt die Batterien ja nicht selber her und wollen das wahrscheinlich auch auch diesem Grund herausrechnen. Die nennen es ja PV-Ertrag und nicht einfach Ertrag.

          T 1 Reply Last reply Reply Quote 0
          • T
            TomRacoon @FernetMenta last edited by

            @fernetmenta
            Das war für mich bisher der Knackpunkt bei dem Plenticore Adapter:
            Yield liefert mir für heute Stand 18:00
            4d1a816f-cffa-4034-8ab3-31cf8c4005d3-image.png
            In der App sehe ich jetzt gerade dann aber eine Gesamterzeugung von 29,1 für heute (auf der lokalen Webseite aber auch nur die 22,8 kW):
            ac8fa0f1-2498-487b-b177-026754ae50a0-image.png

            Den Datenpunkt EnergyChargePv gibt es im "alten" Adapter nicht, ist das dann die Einspeisung in die Batterie?
            Vielleicht schließt das dann ja die Lücke zwischen dem wirklichen ist und dem was ich bisher auslesen kann. Ich schließe erst einmal meine Baustelle mit dem Saugroboter ab und werde dann Deinen neuen Adapter ausprobieren.

            Grüße,
            Chris

            FernetMenta 1 Reply Last reply Reply Quote 0
            • FernetMenta
              FernetMenta @TomRacoon last edited by

              @tomracoon

              Den Datenpunkt EnergyChargePv gibt es im "alten" Adapter nicht, ist das dann die Einspeisung in die Batterie?

              Ja, in die Batterie geht mehr Energie rein als wieder raus. Die Differenz ist der Unterschied von Yield und dem, was im Portal angezeigt wird. Ich würde den Wert im Portal nicht als "wirklich" bezeichnen. Von den Ladeverlusten hast du ja nichts. Im Portal sieht man das auch, aber anders: PV-Ertrag ist nicht die Summe aus Einspeisung und Eigenverbrauch.
              Realistisch betrachtet ist also der nutzbare Ertrag gleich dem Yield und nicht das, was einem im Portal angezeigt wird.

              Viel Spaß erst mal mit dem Roboter! Gruß,
              Rainer

              Homoran 1 Reply Last reply Reply Quote 0
              • Homoran
                Homoran Global Moderator Administrators @FernetMenta last edited by

                @fernetmenta kann der Ertrag auch der DC-seitige Ertrag und deswegen höher als die nutzbare AC Energie sein?

                FernetMenta 1 Reply Last reply Reply Quote 0
                • FernetMenta
                  FernetMenta @Homoran last edited by

                  @homoran sagte in IOBroker Anbindung an einen Kostal Plenticore:

                  @fernetmenta kann der Ertrag auch der DC-seitige Ertrag und deswegen höher als die nutzbare AC Energie sein?

                  Nein, den DC-Ertrag kann man separat mit EnergyFlow/Statistic:EnergyPv1 (2 oder 3) auslesen. Der ist höher, als der PV-Ertrag im Portal.
                  Ich habe mit den verschiedenen Werten lange jongliert und denke, dass die Formel, die ich oben angegeben habe, schon passt.

                  1 Reply Last reply Reply Quote 1
                  • M
                    mule last edited by mule

                    Doppelpost!

                    paradoxe Situation 1 Reply Last reply Reply Quote 0
                    • paradoxe Situation
                      paradoxe Situation @mule last edited by paradoxe Situation

                      Hallo zusammen, was muss ich hir ändern, damit ich diese Warnmeldung nicht mehr im Log von ioB sehen?

                      Daten sehe und bekomme ich.

                      Requesting settings - [{"moduleid":"devices:local","processdataids":["Dc_P","DigitalIn","EM_State","HomeBat_P","HomeGrid_P","HomeOwn_P","HomePv_P","Home_P","Inverter:State","LimitEvuAbs"]},{"moduleid":"devices:local:ac","processdataids":["CosPhi","Frequency","L1_I","L1_P","L1_U","L2_I","L2_P","L2_U","L3_I","L3_P","L3_U","P","Q","S"]},{"moduleid":"devices:local:battery","processdataids":["Cycles","SoC","I","U","P"]},{"moduleid":"devices:local:pv1","processdataids":["I","U","P"]},{"moduleid":"devices:local:pv2","processdataids":["I","U","P"]},{"moduleid":"scb:export","processdataids":["PortalConActive"]},{"moduleid":"scb:statistic:EnergyFlow","processdataids":["Statistic:Autarky:Day","Statistic:Autarky:Month","Statistic:Autarky:Total","Statistic:Autarky:Year","Statistic:EnergyHome:Day","Statistic:EnergyHome:Month","Statistic:EnergyHome:Total","Statistic:EnergyHome:Year","Statistic:EnergyHomeBat:Day","Statistic:EnergyHomeBat:Month","Statistic:EnergyHomeBat:Total","Statistic:EnergyHomeBat:Year","Statistic:EnergyHomeGrid:Day","Statistic:EnergyHomeGrid:Month","Statistic:EnergyHomeGrid:Total","Statistic:EnergyHomeGrid:Year","Statistic:EnergyHomePv:Day","Statistic:EnergyHomePv:Month","Statistic:EnergyHomePv:Total","Statistic:EnergyHomePv:Year","Statistic:OwnConsumptionRate:Day","Statistic:OwnConsumptionRate:Month","Statistic:OwnConsumptionRate:Total","Statistic:OwnConsumptionRate:Year","Statistic:Yield:Day","Statistic:Yield:Month","Statistic:Yield:Total","Statistic:Yield:Year","Statistic:CO2Saving:Day","Statistic:CO2Saving:Month","Statistic:CO2Saving:Year","Statistic:CO2Saving:Total"]}]) failed with code 503: {"message":"internal communication error, try again later"}
                      

                      09f05af6-98fb-49df-b9e8-ad43f16bb77a-{57AAF1E9-472A-4265-88A0-03B78A0F5B8B}.png
                      5620505d-6d36-43e6-acb3-25a5a09fc18c-{962F7051-BA94-41AF-A784-1548B707EC0C}.png

                      FernetMenta 1 Reply Last reply Reply Quote 0
                      • FernetMenta
                        FernetMenta @paradoxe Situation last edited by

                        @paradoxe-situation kannst du nicht ändern, da dieser Adapter nicht mehr gepflegt wird und Fehler hat. Ich habe aus diesem Grund einen neuen geschrieben: plenticore-g3

                        Diginix 1 Reply Last reply Reply Quote 0
                        • Diginix
                          Diginix @FernetMenta last edited by

                          @fernetmenta Ich habe einen PLENTICORE plus 5.5 und bin mit dem Adapter seit Jahren fehlerfrei zufrieden. Ist dein Adapter mit meinem WR kompatibel?
                          Neben den klassischen Werten, die ich parallel schon immer auch per modbus beziehe, hat der Plenticore Adapter auch noch eine Ertragsprognose. Hat das dein Adapter auch?
                          Gibt es irgendwo - bei github habe ich nix gefunden - eine Feature Übersicht und ggf. ein Screenshot vom Objektbaum?

                          FernetMenta 1 Reply Last reply Reply Quote 0
                          • FernetMenta
                            FernetMenta @Diginix last edited by

                            @diginix

                            Ist dein Adapter mit meinem WR kompatibel?

                            Ich denke schon. Ist die gleiche API, nur ggf andere Datenpunkte. Darum habe ich es so gemacht, dass ein Benutzer selber bestimmen kann, welche Datenpunkte er haben möchte. Man kann alles aus ProcessData uind Settings (siehe API doc) abrufen. Die Bedeutung kann man in den meisten Fällen direkt aus den Namen ableiten.
                            Hier ist der Testing thread: https://forum.iobroker.net/topic/80275/beta-iobroker-plenticore-g3

                            Und die Doku: https://github.com/FernetMenta/ioBroker.plenticore-g3

                            1 Reply Last reply Reply Quote 0
                            • First post
                              Last post

                            Support us

                            ioBroker
                            Community Adapters
                            Donate

                            681
                            Online

                            31.6k
                            Users

                            79.5k
                            Topics

                            1.3m
                            Posts

                            83
                            1302
                            323974
                            Loading More Posts
                            • Oldest to Newest
                            • Newest to Oldest
                            • Most Votes
                            Reply
                            • Reply as topic
                            Log in to reply
                            Community
                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                            The ioBroker Community 2014-2023
                            logo