    Wärmepumpe Daikin Altherma 3 H HT und ioBroker

    This topic has been deleted. Only users with topic management privileges can see it.
    • R
      robmann last edited by

      Register-Einstellung sieht wie folgt aus:

      c9d0c1e0-49d6-494e-a592-19d7119efaee-grafik.png

      zum Vergleich: Register 40009 und 40056 identisch konfiguriert. Das setzten von "Leise-Modus" klappt.

      D 1 Reply Last reply Reply Quote 0
      • R
        robmann @Homoran last edited by

        @homoran Interessant... woher stammt diese Info? Habe ich so nicht gefunden.
        Wie genau würde die Freischaltung erfolgen?

        Homoran 1 Reply Last reply Reply Quote 0
        • Homoran
          Homoran Global Moderator Administrators @robmann last edited by

          @robmann sagte in Wärmepumpe Daikin Altherma 3 H HT und ioBroker:

          Interessant... woher stammt diese Info?

          aus der DCOM Anleitung

          @robmann sagte in Wärmepumpe Daikin Altherma 3 H HT und ioBroker:

          Wie genau würde die Freischaltung erfolgen?

          keine Ahnung. müsste im Monteurmodus in der Altherma zu finden sein.
          Wobei dann wahrscheinlich auch noch bestimmte Voraussetzungen erfüllt sein müssen.

          1 Reply Last reply Reply Quote 0
          • D
            Diet_Po @robmann last edited by

            @robmann said in Wärmepumpe Daikin Altherma 3 H HT und ioBroker:

            @homoran said in Wärmepumpe Daikin Altherma 3 H HT und ioBroker:

            Es geht dir wahrscheinlich um "Anwendungsfall 3" , Einbindung ins Smarthome

            ganz genau... und das ganze ein wenig visualisieren 😉

            Hallo, bin gerade in der Situation den Modbus TCP (Daikin Altherma 3 mit Wlan-Adapter und Homehub) in Betrieb zu nehmen - Verbindung bricht immer wieder nach 1 sec ab.
            IOB-Log
            c83e7ac0-21d9-4748-bfba-70cfb340e752-image.png
            IOB-Instanz-Modbus
            0b53d3c8-97fb-4f45-bcf4-4357df6f93ad-image.png
            IOB-Instanz-Modbus Register
            5b1c7ade-d526-4e82-90ef-7ea576b2ebc5-image.png
            Habe alle möglichen Verbindungen probiert keine Ahnung mehr, was ich noch machen soll.
            Vielleicht habt ihr nen Tipp

            wendy2702 Homoran 2 Replies Last reply Reply Quote 0
            • wendy2702
              wendy2702 @Diet_Po last edited by

              @diet_po Erster Tipp:

              Das logfile als Text in Code Tag </> Posten damit es zitier und lesbar ist.

              1 Reply Last reply Reply Quote 0
              • Homoran
                Homoran Global Moderator Administrators @Diet_Po last edited by Homoran

                @diet_po bitte auch keine Screenshots mit 2k Auflösung!

                habs trotzdem versucht zu entziffern.

                Was steht in der Registerbeschreibung des Getätes?

                wieso Holdingregister?
                Wieso Alias?

                D 1 Reply Last reply Reply Quote 0
                • D
                  Diet_Po @Homoran last edited by Homoran

                  @homoran
                  Sorry bin neu im Forum - versuch mich zu bessern

                  Ich habe die Einstellungen von Robbman übernommen, sollte ja genauso sein.
                  Problem ist die Verbindung hier nochmal die Log als Text:

                  modbus.0
                  2025-05-12 11:01:41.819	info	Disconnected from slave 192.168.178.213
                  
                  modbus.0
                  2025-05-12 11:01:41.818	debug	Closing client on purpose.
                  
                  modbus.0
                  2025-05-12 11:01:40.819	debug	Cleaning up request fifo.
                  
                  modbus.0
                  2025-05-12 11:01:40.818	debug	Clearing timeout of the current request.
                  
                  modbus.0
                  2025-05-12 11:01:40.818	debug	Socket closed with error
                  
                  modbus.0
                  2025-05-12 11:01:40.813	debug	[DevID_1/holdingRegs] Poll address 40009 - 1 registers
                  
                  modbus.0
                  2025-05-12 11:01:40.812	debug	[DevID_1] Poll start ---------------------
                  
                  modbus.0
                  2025-05-12 11:01:40.812	info	Connected to slave 192.168.178.213
                  
                  modbus.0
                  2025-05-12 11:00:40.809	info	Disconnected from slave 192.168.178.213
                  
                  modbus.0
                  2025-05-12 11:00:40.808	debug	Closing client on purpose.
                  
                  modbus.0
                  2025-05-12 11:00:39.808	debug	Cleaning up request fifo.
                  
                  modbus.0
                  2025-05-12 11:00:39.808	debug	Clearing timeout of the current request.
                  
                  modbus.0
                  2025-05-12 11:00:39.807	debug	Socket closed with error
                  
                  modbus.0
                  2025-05-12 11:00:39.803	debug	[DevID_1/holdingRegs] Poll address 40009 - 1 registers
                  
                  modbus.0
                  2025-05-12 11:00:39.803	debug	[DevID_1] Poll start ---------------------
                  
                  modbus.0
                  2025-05-12 11:00:39.803	info	Connected to slave 192.168.178.213
                  

                  MOD-EDIT: Code in code-tags gesetzt!

                  Homoran wendy2702 2 Replies Last reply Reply Quote 0
                  • Homoran
                    Homoran Global Moderator Administrators @Diet_Po last edited by

                    @diet_po sagte in Wärmepumpe Daikin Altherma 3 H HT und ioBroker:

                    Ich habe die Einstellungen von Robbman übernommen

                    da finde ich nichts von Alias

                    1 Reply Last reply Reply Quote 0
                    • wendy2702
                      wendy2702 @Diet_Po last edited by

                      @diet_po mach den haken bei "Aliases benutzen" raus.

                      1 Reply Last reply Reply Quote 0
                      • D
                        Diet_Po last edited by Homoran

                        Hallo zusammen
                        Ich scheiter gerade an der Modbusanbindung meiner WÄRMEPUMPE
                        Keine Verbindung
                        Modbus tcp port802
                        Holding-Register: 40009; 16 bit signed; level
                        Hat einer ne Idee/Lösung
                        Danke schon mal

                        Zeit
                        debug
                        Nachricht

                        modbus.0
                        2025-05-13 23:29:03.977	info	Disconnected from slave 192.168.178.213
                        
                        modbus.0
                        2025-05-13 23:29:03.976	debug	Closing client on purpose.
                        
                        modbus.0
                        2025-05-13 23:29:02.977	debug	Cleaning up request fifo.
                        
                        modbus.0
                        2025-05-13 23:29:02.976	debug	Clearing timeout of the current request.
                        
                        modbus.0
                        2025-05-13 23:29:02.976	debug	Socket closed with error
                        
                        modbus.0
                        2025-05-13 23:29:02.974	error	Wrong CRC for frame: 21,3,3,0,2,2,22,21
                        
                        modbus.0
                        2025-05-13 23:29:02.971	debug	Sending pdu to the socket.
                        
                        modbus.0
                        2025-05-13 23:29:02.970	debug	[DevID_1/holdingRegs] Poll address 40009 - 1 registers
                        
                        modbus.0
                        2025-05-13 23:29:02.970	debug	[DevID_1] Poll start ---------------------
                        
                        modbus.0
                        2025-05-13 23:29:02.969	info	Connected to slave
                        
                        modbus.0
                        2025-05-13 23:28:02.966	info	Disconnected from slave 192.168.178.213
                        
                        modbus.0
                        2025-05-13 23:28:02.966	debug	Closing client on purpose.
                        
                        modbus.0
                        2025-05-13 23:28:01.965	debug	Cleaning up request fifo.
                        
                        modbus.0
                        2025-05-13 23:28:01.965	debug	Clearing timeout of the current request.
                        
                        modbus.0
                        2025-05-13 23:28:01.965	debug	Socket closed with error
                        
                        modbus.0
                        2025-05-13 23:28:01.953	debug	Sending pdu to the socket.
                        
                        modbus.0
                        2025-05-13 23:28:01.953	debug	[DevID_1/holdingRegs] Poll address 40009 - 1 registers
                        
                        modbus.0
                        2025-05-13 23:28:01.952	debug	Initialization of scale factors done!
                        
                        modbus.0
                        2025-05-13 23:28:01.951	debug	[DevID_1] Poll start ---------------------
                        
                        modbus.0
                        2025-05-13 23:28:01.951	info	Connected to slave
                        
                        modbus.0
                        2025-05-13 23:28:01.842	debug	Add holdingRegisters.40009_test1: {"_id":"holdingRegisters.40009_test1","type":"state","common":{"name":"bl","role":"level","type":"number","read":true,"write":true,"def":0,"unit":""},"native":{"regType":"holdingRegs","address":40009,"deviceId":1,"type":"int16le","len":1,"offset":0,"factor":1,"poll":true}}
                        
                        modbus.0
                        2025-05-13 23:28:01.842	debug	Initialize Objects for holdingRegs: [{"_address":"40009","name":"test1","description":"bl","unit":"","type":"int16le","len":1,"factor":1,"offset":0,"formula":"","role":"level","room":"","poll":true,"wp":"","cw":"","isScale":"","address":40009,"deviceId":1,"id":"holdingRegisters.40009_test1"}]
                        
                        modbus.0
                        2025-05-13 23:28:01.841	debug	Initialize Objects for inputRegs: []
                        
                        modbus.0
                        2025-05-13 23:28:01.841	debug	Initialize Objects for coils: []
                        
                        modbus.0
                        2025-05-13 23:28:01.841	debug	Initialize Objects for disInputs: []
                        
                        modbus.0
                        2025-05-13 23:28:01.789	info	starting. Version 6.3.2 in /opt/iobroker/node_modules/iobroker.modbus, node: v20.18.0, js-controller: 7.0.6
                        
                        modbus.0
                        2025-05-13 23:28:01.645	debug	Plugin sentry Initialize Plugin (enabled=true)
                        
                        modbus.0
                        2025-05-13 23:28:01.631	debug	States connected to redis: 127.0.0.1:9000
                        
                        modbus.0
                        2025-05-13 23:28:01.582	debug	States create User PubSub Client
                        
                        modbus.0
                        2025-05-13 23:28:01.581	debug	States create System PubSub Client
                        
                        modbus.0
                        2025-05-13 23:28:01.577	debug	Redis States: Use Redis connection: 127.0.0.1:9000
                        
                        modbus.0
                        2025-05-13 23:28:01.559	debug	Objects connected to redis: 127.0.0.1:9001
                        
                        modbus.0
                        2025-05-13 23:28:01.551	debug	Objects client initialize lua scripts
                        
                        modbus.0
                        2025-05-13 23:28:01.536	debug	Objects create User PubSub Client
                        
                        modbus.0
                        2025-05-13 23:28:01.536	debug	Objects create System PubSub Client
                        
                        modbus.0
                        2025-05-13 23:28:01.535	debug	Objects client ready ... initialize now
                        

                        MOD-EDIT: Code in code-tags gesetzt!

                        M wendy2702 2 Replies Last reply Reply Quote 0
                        • M
                          MCU @Diet_Po last edited by

                          @diet_po evtl hilft dies?
                          https://forum.iobroker.net/topic/37536/wärmepumpe-daikin-altherma-3-h-ht-und-iobroker/74

                          D 1 Reply Last reply Reply Quote 0
                          • D
                            Diet_Po @MCU last edited by

                            @mcu danke. Aber der ist von mir😂

                            Homoran 1 Reply Last reply Reply Quote 0
                            • Homoran
                              Homoran Global Moderator Administrators @Diet_Po last edited by

                              @diet_po sagte in Daikin Altherma 3 Modbusanbindung:

                              @mcu danke. Aber der ist von mir😂

                              und warum dann einen weiteten Thread, anstelke da zu antworten und weitere Infos zu geben?

                              D 1 Reply Last reply Reply Quote 0
                              • D
                                Diet_Po @Homoran last edited by

                                @homoran wie man macht ist es falsch, bin neu hier und muss mich erst an die Umgebung und den Aufbau des Forums gewöhnen - Sorry.
                                Wie soll ich jetzt vorgehen ?

                                Homoran 1 Reply Last reply Reply Quote 0
                                • Homoran
                                  Homoran Global Moderator Administrators @Diet_Po last edited by

                                  @diet_po sagte in Wärmepumpe Daikin Altherma 3 H HT und ioBroker:

                                  Wie soll ich jetzt vorgehen ?

                                  ich habs zusammengeführt

                                  @diet_po sagte in Wärmepumpe Daikin Altherma 3 H HT und ioBroker:

                                  muss mich erst an die Umgebung und den Aufbau des Forums gewöhnen

                                  etwas Lesestoff
                                  https://forum.iobroker.net/topic/51555/hinweise-für-gute-forenbeiträge/1

                                  1 Reply Last reply Reply Quote 0
                                  • wendy2702
                                    wendy2702 @Diet_Po last edited by wendy2702

                                    @diet_po sagte in Wärmepumpe Daikin Altherma 3 H HT und ioBroker:

                                    Modbus tcp port802

                                    Sehr Ungewöhnlich wenn das kein Tippfehler ist.

                                    EDIT:

                                    @diet_po sagte in Wärmepumpe Daikin Altherma 3 H HT und ioBroker:

                                    Ich habe die Einstellungen von Robbman übernommen, sollte ja genauso sein.

                                    Von wo? Ich konnte in dem Thread nur paar Screenshots von Registern sehen.

                                    Zeige nochmal deine Einstellungen und hast du denn die Hardware die @robmann hat was die WP betrifft?

                                    1 Reply Last reply Reply Quote 1
                                    • D
                                      Diet_Po last edited by

                                      Mein Modbus TCP will einfach nicht an meiner Daikin Altherma -Wärmepumpe laufen
                                      hat einer von euch evtl. die Einstellungen von der Wärmepumpe und vom ioBroker - bin langsam am Verzweifeln 🙂

                                      hier mal Screenshot's von meinen TestModbus_log.png Modbus.png Modbus1.png

                                      wendy2702 Homoran 2 Replies Last reply Reply Quote 0
                                      • wendy2702
                                        wendy2702 @Diet_Po last edited by wendy2702

                                        @diet_po Wir hatten dich bereits mehrfach gebeten logs als Text in Code Tags zu posten und nicht als Screenshot. Kannst du das bitte ändern.

                                        Weiterhin glaube ich nicht das Port 802 richtig ist. Woher hast du diesen Wert?

                                        Der "Standart Port" für Modbus TCP ist bei 99,5% aller Geräte 502, oder hast du den an der WP so eingestellt?

                                        EDIT: Mal im Screenshot der Register Einstellungen von Robmann geschaut, der verwendet "Signed 16 bit (Big Endian), warum hast du dann "Little Endian" ausgewählt?

                                        D 1 Reply Last reply Reply Quote 1
                                        • Homoran
                                          Homoran Global Moderator Administrators @Diet_Po last edited by Homoran

                                          @diet_po sagte in Wärmepumpe Daikin Altherma 3 H HT und ioBroker:

                                          hier mal Screenshot's von meinen Test

                                          sorry, da kann msn witklich nicht helfen
                                          Screenshot_20250516-115254_Firefox.jpg

                                          Erstens Screeshot von Text und dann noch 2.5k!
                                          So viel Auflösung hat kein Handy!

                                          1 Reply Last reply Reply Quote 0
                                          • D
                                            Diet_Po @wendy2702 last edited by

                                            @wendy2702
                                            Port 802 ist tls 502 ungesichert, egal welche Einstellung gich verwende funzt beides nicht ebso ob 16 bit little oder big endian oder anderes Register.
                                            Habe mittlerweile von Daikin Antwort bekommen, soll Homebox mal reseten - werde ich die Tage mal testen und mich dann berichten.
                                            Sorry nochmal für Screenshots

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate
                                            FAQ Cloud / IOT
                                            HowTo: Node.js-Update
                                            HowTo: Backup/Restore
                                            Downloads
                                            BLOG

                                            950
                                            Online

                                            31.9k
                                            Users

                                            80.1k