    Compleo Wallbox nimmt ModBus-Parameter nicht an

    This topic has been deleted. Only users with topic management privileges can see it.
    • L
      luas last edited by

      Wir haben eine Compleo eBox im Einsatz, die ich gerne für Überschussladen konfigurieren möchte. Sprich: ich möchte den maximalen Ladestrom dynamisch aus IOBroker vorgeben. Leider ignoriert die eBox diese Vorgaben.
      Per ModBus bin ich bereits erfolgreich mit der Box in Kontakt und lese diverse Parameter aus:
      e407a362-cc3e-4b13-88f8-f8188e12ac01-image.png
      Auch das Schreiben von Werten habe ich eingerichtet:
      29d12e9b-622e-45b5-bab6-b2c1c5e9fea6-image.png
      Hier ein Test, wo ich (rot) verschiedene Werte vorgebe, was (grün) ignoriert wird, wie es scheint:
      5f2facf0-f10e-409f-9207-d3e453ae7608-image.png
      Ich war länger mit dem Compleo-Support in Kontakt und der meinte, die ModBus-Befehle würden nicht bei der eBox ankommen. Und schickte mir natürlich eine Liste "unterstützer Energiemanagementsysteme".
      Ich kann mir nicht recht erklären, dass die Werte nicht ankommen - wenn dem so wäre, würde ich das ja durch das gesetzte Häkchen "Abfrage" in IOBroker feststellen, oder?

      Danke für eure Ideen!

      L arteck 2 Replies Last reply Reply Quote 0
      • L
        luas @luas last edited by

        Okay, womöglich habe ich die Hinweise für gute Forenbeiträge missachtet...

        Hier ein Screenshot der grundsätzliche Adapterkonfiguration:
        58c04ffe-273a-44ac-a386-c8b7d1d4c1f8-image.png

        Und hier die Logausgabe nach Start des Adapters:

        
        
        
        modbus.5
        2025-05-15 21:53:25.466	debug	[DevID_1/holdingRegs] Poll address 1012 DONE
        
        modbus.5
        2025-05-15 21:53:25.416	debug	[DevID_1/holdingRegs] Poll address 1012 - 13 registers
        
        modbus.5
        2025-05-15 21:53:25.413	debug	[DevID_1/inputRegs] Poll address 1006 DONE
        
        modbus.5
        2025-05-15 21:53:25.409	debug	[DevID_1/inputRegs] Poll address 1006 - 6 registers
        
        modbus.5
        2025-05-15 21:53:25.406	debug	[DevID_1/inputRegs] Poll address 300 DONE
        
        modbus.5
        2025-05-15 21:53:25.401	debug	[DevID_1/inputRegs] Poll address 300 - 1 registers
        
        modbus.5
        2025-05-15 21:53:25.396	debug	[DevID_1/inputRegs] Poll address 275 DONE
        
        modbus.5
        2025-05-15 21:53:25.387	debug	[DevID_1/inputRegs] Poll address 275 - 2 registers
        
        modbus.5
        2025-05-15 21:53:25.387	debug	Initialization of scale factors done!
        
        modbus.5
        2025-05-15 21:53:25.385	debug	[DevID_1] Poll start ---------------------
        
        modbus.5
        2025-05-15 21:53:25.383	info	Connected to slave 192.168.6.73
        
        modbus.5
        2025-05-15 21:53:24.864	debug	Add holdingRegisters.1024_RemainingTimeBeforeFallback: {"_id":"holdingRegisters.1024_RemainingTimeBeforeFallback","type":"state","common":{"name":"","role":"level","type":"number","read":true,"write":true,"def":0,"unit":"s"},"native":{"regType":"holdingRegs","address":1024,"deviceId":1,"type":"uint16be","len":1,"offset":0,"factor":1,"poll":true}}
        
        modbus.5
        2025-05-15 21:53:24.864	debug	Add holdingRegisters.1022_FallbackMaxCurrent3: {"_id":"holdingRegisters.1022_FallbackMaxCurrent3","type":"state","common":{"name":"","role":"level","type":"number","read":true,"write":true,"def":0,"unit":"A"},"native":{"regType":"holdingRegs","address":1022,"deviceId":1,"type":"floatbe","len":2,"offset":0,"factor":1,"poll":true}}
        
        modbus.5
        2025-05-15 21:53:24.863	debug	Add holdingRegisters.1020_FallbackMaxCurrent2: {"_id":"holdingRegisters.1020_FallbackMaxCurrent2","type":"state","common":{"name":"","role":"level","type":"number","read":true,"write":true,"def":0,"unit":"A"},"native":{"regType":"holdingRegs","address":1020,"deviceId":1,"type":"floatbe","len":2,"offset":0,"factor":1,"poll":true}}
        
        modbus.5
        2025-05-15 21:53:24.863	debug	Add holdingRegisters.1018_FallbackMaxCurrent1: {"_id":"holdingRegisters.1018_FallbackMaxCurrent1","type":"state","common":{"name":"","role":"level","type":"number","read":true,"write":true,"def":0,"unit":"A"},"native":{"regType":"holdingRegs","address":1018,"deviceId":1,"type":"floatbe","len":2,"offset":0,"factor":1,"poll":true}}
        
        modbus.5
        2025-05-15 21:53:24.863	debug	Add holdingRegisters.1016_MaxCurrentPhase3: {"_id":"holdingRegisters.1016_MaxCurrentPhase3","type":"state","common":{"name":"","role":"level","type":"number","read":true,"write":true,"def":0,"unit":"A"},"native":{"regType":"holdingRegs","address":1016,"deviceId":1,"type":"floatbe","len":2,"offset":0,"factor":1,"poll":true}}
        
        modbus.5
        2025-05-15 21:53:24.862	debug	Add holdingRegisters.1014_MaxCurrentPhase2: {"_id":"holdingRegisters.1014_MaxCurrentPhase2","type":"state","common":{"name":"","role":"level","type":"number","read":true,"write":true,"def":0,"unit":"A"},"native":{"regType":"holdingRegs","address":1014,"deviceId":1,"type":"floatbe","len":2,"offset":0,"factor":1,"poll":true}}
        
        modbus.5
        2025-05-15 21:53:24.862	debug	Add holdingRegisters.1012_MaxCurrentPhase1: {"_id":"holdingRegisters.1012_MaxCurrentPhase1","type":"state","common":{"name":"","role":"level","type":"number","read":true,"write":true,"def":0,"unit":"A"},"native":{"regType":"holdingRegs","address":1012,"deviceId":1,"type":"floatbe","len":2,"offset":0,"factor":1,"poll":true}}
        
        modbus.5
        2025-05-15 21:53:24.861	debug	Initialize Objects for holdingRegs: [{"_address":1012,"name":"MaxCurrentPhase1","description":"","unit":"A","type":"floatbe","len":2,"factor":1,"offset":0,"formula":"","role":"level","room":"","poll":true,"wp":"","cw":false,"isScale":"","address":1012,"deviceId":1,"id":"holdingRegisters.1012_MaxCurrentPhase1"},{"_address":1014,"name":"MaxCurrentPhase2","description":"","unit":"A","type":"floatbe","len":2,"factor":1,"offset":0,"formula":"","role":"level","room":"","poll":true,"wp":"","cw":false,"isScale":"","address":1014,"deviceId":1,"id":"holdingRegisters.1014_MaxCurrentPhase2"},{"_address":1016,"name":"MaxCurrentPhase3","description":"","unit":"A","type":"floatbe","len":2,"factor":1,"offset":0,"formula":"","role":"level","room":"","poll":true,"wp":"","cw":false,"isScale":"","address":1016,"deviceId":1,"id":"holdingRegisters.1016_MaxCurrentPhase3"},{"_address":1018,"name":"FallbackMaxCurrent1","description":"","unit":"A","type":"floatbe","len":2,"factor":1,"offset":0,"formula":"","role":"level","room":"","poll":true,"wp":"","cw":false,"isScale":"","address":1018,"deviceId":1,"id":"holdingRegisters.1018_FallbackMaxCurrent1"},{"_address":1020,"name":"FallbackMaxCurrent2","description":"","unit":"A","type":"floatbe","len":2,"factor":1,"offset":0,"formula":"","role":"level","room":"","poll":true,"wp":"","cw":false,"isScale":"","address":1020,"deviceId":1,"id":"holdingRegisters.1020_FallbackMaxCurrent2"},{"_address":1022,"name":"FallbackMaxCurrent3","description":"","unit":"A","type":"floatbe","len":2,"factor":1,"offset":0,"formula":"","role":"level","room":"","poll":true,"wp":"","cw":false,"isScale":"","address":1022,"deviceId":1,"id":"holdingRegisters.1022_FallbackMaxCurrent3"},{"_address":1024,"name":"RemainingTimeBeforeFallback","description":"","unit":"s","type":"uint16be","len":1,"factor":1,"offset":0,"formula":"","role":"level","room":"","poll":true,"wp":"","cw":false,"isScale":"","address":1024,"deviceId":1,"id":"holdingRegisters.1024_RemainingTimeBeforeFallback"}]
        
        modbus.5
        2025-05-15 21:53:24.860	debug	Add inputRegisters.1010_CurrentPhase3: {"_id":"inputRegisters.1010_CurrentPhase3","type":"state","common":{"name":"","role":"level","type":"number","read":true,"write":false,"def":0,"unit":"A"},"native":{"regType":"inputRegs","address":1010,"deviceId":1,"type":"floatbe","len":2,"offset":0,"factor":1}}
        
        modbus.5
        2025-05-15 21:53:24.859	debug	Add inputRegisters.1008_CurrentPhase2: {"_id":"inputRegisters.1008_CurrentPhase2","type":"state","common":{"name":"","role":"level","type":"number","read":true,"write":false,"def":0,"unit":"A"},"native":{"regType":"inputRegs","address":1008,"deviceId":1,"type":"floatbe","len":2,"offset":0,"factor":1}}
        
        modbus.5
        2025-05-15 21:53:24.859	debug	Add inputRegisters.1006_CurrentPhase1: {"_id":"inputRegisters.1006_CurrentPhase1","type":"state","common":{"name":"","role":"level","type":"number","read":true,"write":false,"def":0,"unit":"A"},"native":{"regType":"inputRegs","address":1006,"deviceId":1,"type":"floatbe","len":2,"offset":0,"factor":1}}
        
        modbus.5
        2025-05-15 21:53:24.859	debug	Add inputRegisters.300_Cable_State: {"_id":"inputRegisters.300_Cable_State","type":"state","common":{"name":"","role":"level","type":"number","read":true,"write":false,"def":0,"unit":""},"native":{"regType":"inputRegs","address":300,"deviceId":1,"type":"uint16be","len":1,"offset":0,"factor":1}}
        
        modbus.5
        2025-05-15 21:53:24.858	debug	Add inputRegisters.275_Mode_3_State: {"_id":"inputRegisters.275_Mode_3_State","type":"state","common":{"name":"","role":"level","type":"string","read":true,"write":false,"def":"","unit":""},"native":{"regType":"inputRegs","address":275,"deviceId":1,"type":"string","len":2,"offset":0,"factor":1}}
        
        modbus.5
        2025-05-15 21:53:24.857	debug	Initialize Objects for inputRegs: [{"_address":275,"name":"Mode 3 State","description":"","unit":"","type":"string","len":2,"factor":1,"offset":0,"formula":"","role":"level","room":"","cw":"","isScale":"","address":275,"deviceId":1,"id":"inputRegisters.275_Mode_3_State"},{"_address":300,"name":"Cable State","description":"","unit":"","type":"uint16be","len":1,"factor":1,"offset":0,"formula":"","role":"level","room":"","cw":"","isScale":"","address":300,"deviceId":1,"id":"inputRegisters.300_Cable_State"},{"_address":1006,"name":"CurrentPhase1","description":"","unit":"A","type":"floatbe","len":2,"factor":1,"offset":0,"formula":"","role":"level","room":"","cw":"","isScale":"","deviceId":1,"address":1006,"id":"inputRegisters.1006_CurrentPhase1"},{"_address":1008,"name":"CurrentPhase2","description":"","unit":"A","type":"floatbe","len":2,"factor":1,"offset":0,"formula":"","role":"level","room":"","cw":"","isScale":"","deviceId":1,"address":1008,"id":"inputRegisters.1008_CurrentPhase2"},{"_address":1010,"name":"CurrentPhase3","description":"","unit":"A","type":"floatbe","len":2,"factor":1,"offset":0,"formula":"","role":"level","room":"","cw":"","isScale":"","deviceId":1,"address":1010,"id":"inputRegisters.1010_CurrentPhase3"}]
        
        modbus.5
        2025-05-15 21:53:24.856	debug	Initialize Objects for coils: []
        
        modbus.5
        2025-05-15 21:53:24.856	debug	Initialize Objects for disInputs: []
        
        modbus.5
        2025-05-15 21:53:24.627	info	starting. Version 6.3.2 in /opt/iobroker/node_modules/iobroker.modbus, node: v20.19.0, js-controller: 7.0.6
        
        
        

        Anschließend sehe ich minütlich wiederholend die Einträge wie "[DevID_1/holdingRegs] Poll address 1012 - 13 registers". Da verwirrt mich ein wenig, dass nicht alle sieben konfigurierten Holding-Register aufgeführt werden - aber vielleicht hat das auch seine Richtigkeit.

        P 1 Reply Last reply Reply Quote 0
        • P
          peterfido @luas last edited by peterfido

          @luas Ab Adresse 1012 liest er 13 Register. Das passt. Für Modbus nutze ich selbst Node-Red. Kann da also leider nicht mehr zu sagen.

          1 Reply Last reply Reply Quote 0
          • arteck
            arteck Developer Most Active @luas last edited by

            @luas wo hast du die modbus Beschreibung ??

            zeigmal..

            L 1 Reply Last reply Reply Quote 0
            • L
              luas @arteck last edited by

              @arteck Hier die aktuellste ModBus-Definition zur Compleo eBox, die mir vorliegt: DE_Quickguide_eBOX_-_Modbus_Energiemanagement_20230814.pdf
              Aber hey, Moment mal, haben die den angeblich nicht vorhandenen Bug stillschweigend gefixt?
              Ich war heute erfolglos auf der Suche nach einer aktuelleren ModBus-Definition und stieß stattdessen darauf, dass es eine neue Firmware gibt. Da ohnehin irgendwas vergurkt war (die Wallbox kam seit zwei Tagen nicht mehr aus dem EVSE-State B1 "Wallbox not ready" raus), habe ich die installiert, und auf den ersten Blick fluppt es seither.
              In den Release Notes heißt es: "Fixed an issue where local load management was not started properly". Vielleicht war's das.
              Hier das Diagramm meiner aktuellen Tests:
              60696b10-1a59-496c-9c0d-b395522a97e6-image.png
              Anfangs lädt das Auto ungedrosselt, bis die Vorgabe (in grau) dazukommt. Der folgt es brav, außer wenn man unter 6A geht (im Bild gegen 19:53). Das wird dann seitens der Wallbox wieder auf den Minimalwert 6A hochgeschubst.
              Erlaubt dagegen ist (im Bild gegen 20 Uhr) eine Vorgabe von 0A, die in einem "Wallbox not ready" resultiert. Das halbe Ampere, das da noch angezeigt wird, ist der angebliche Eigenverbrauch der Wallbox. Glaube ich nicht, aber soll hier egal sein. Jedenfalls bekommt das Auto keinen Strom mehr.
              An der Stelle hatte sich die Wallbox vermutlich vor dem Update verschluckt und blieb da hängen. Hier ist zu sehen, wie sie das Laden wieder aufnimmt, sobald die Vorgabe wieder >=6A ist.
              Scheint also alles schick. Herzlichen Dank euch! Auch wenn ihr primär das Rubber Ducky wart.

              L 1 Reply Last reply Reply Quote 1
              • L
                luas @luas last edited by

                @luas Okay, und noch ein Fehler war drin, der mangels Blockly-Screenshot nicht zu erkennen war: ich habe die Werte in Blockly "aktualisiert" statt "gesteuert". In obigem Screenshot waren es manuell gesetzte (unbestätigte) Vorgaben.
                Peinlich, ich gehe im Geiste noch mal in die Abteilung "Einsteigerfragen" zurück.
                Jetzt bin ich aber wirklich zuversichtlich, dass es klappt!
                Das hat mir auf die Sprünge geholfen: https://youtu.be/p5FyeifYUnw

                L 1 Reply Last reply Reply Quote 0
                • L
                  luas @luas last edited by

                  @luas Noch eine Erkenntnis (falls euch meine Selbstgespräche stören, sagt Bescheid, aber vielleicht hilft es ja noch jemandem): manchen Fahrzeugen scheint 6 Ampere als Untergrenze zu wenig, sie pausieren dann komplett. Für eines unserer Fahrzeuge musste ich die Untergrenze auf 10 A erhöhen.

                  1 Reply Last reply Reply Quote 1
                  • First post
                    Last post

                  Support us

                  ioBroker
                  Community Adapters
                  Donate

                  1.1k
                  Online

                  31.7k
                  Users

                  79.7k
                  Topics

                  1.3m
                  Posts

                  3
                  7
                  168
                  Loading More Posts
                  • Oldest to Newest
                  • Newest to Oldest
                  • Most Votes
                  Reply
                  • Reply as topic
                  Log in to reply
                  Community
                  Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                  The ioBroker Community 2014-2023
                  logo