Navigation

    Logo
    • Register
    • Login
    • Search
    • Recent
    • Tags
    • Unread
    • Categories
    • Unreplied
    • Popular
    • GitHub
    • Docu
    • Hilfe
    1. Home
    2. Deutsch
    3. Tester
    4. Tester Zigbee Adapter 3.x gesucht

    NEWS

    • ioBroker@Smart Living Forum Solingen, 14.06. - Agenda added

    • ioBroker goes Matter ... Matter Adapter in Stable

    • Monatsrückblick - April 2025

    Tester Zigbee Adapter 3.x gesucht

    This topic has been deleted. Only users with topic management privileges can see it.
    • Asgothian
      Asgothian Developer @Gaspode last edited by Asgothian

      @gaspode soweit ich sehe, ist eine schlechte Aussage. Du müsstest also das Log von einem Start noch mal posten, insbesondere auch mit dem gestarteten zigbee subsystem.

      Auch das herausnehmen des externen Converters ist interessant.

      Ich habe selber keine Windows Installation. Es ist also denkbar, dass da Effekte existieren.

      Gaspode 1 Reply Last reply Reply Quote 0
      • Gaspode
        Gaspode @Asgothian last edited by Gaspode

        @asgothian said in Tester Zigbee Adapter 3.x gesucht:

        Ich habe selber keine Windows Installation. Es ist also denkbar, dass da Effekte existieren.

        Ich mache spätestens morgen eine Testinstalltion, dann kann ich alles einzeln testen, ohne Angst zu haben, dass ich mir was zerschieße. Danke schon mal.

        Edit:
        OK, mein uralt CC2531 Zigbee USB Stick, mit dem ich testen wollte, wird leider nicht von meinem Rechner erkannt. Muss mir erst mal einen neuen, aktuellen besorgen.

        Was mir schon so auffällt, sind eine paar Grafiken, die auf der Konfigurationsseite nicht angezeigt werden, und zwar unter

        http://localhost:8121/adapter/zigbee/img/
        

        z.B.

        http://localhost:8121/adapter/zigbee/img/channel_scan.png
        

        Installation zum Test auf lokalem Windows PC.

        Mehr, sobald mein Zigbee Stick da ist, wahrscheinlich morgen gegen Abend.

        Asgothian 2 Replies Last reply Reply Quote 0
        • Asgothian
          Asgothian Developer @Gaspode last edited by

          @gaspode das ist ein Bug in der 3.0.1 - die sollten nach Installation von Github und folgendem Upload verfügbar sein.

          A.

          1 Reply Last reply Reply Quote 1
          • Asgothian
            Asgothian Developer @Gaspode last edited by

            @gaspode Bitte vor dem Test nochmal von Github installieren.

            Ich hab da eine Vermutung woran es liegt.

            Bitte beim Test auch mal im externen Konverter das 'icon' entfernen - es ist denkbar das dieses aktuell noch bugged - das ist eine der Funktionen in 3.0.x die ich aktuell nicht sauber getestet bekomme.

            arteck Gaspode 2 Replies Last reply Reply Quote 1
            • arteck
              arteck Developer Most Active @Asgothian last edited by

              @asgothian gibts da win problem mit den runnterladen von icons.. die scheinen in zigbee2mqtt nicht sauber abgelegt worden zu sein..

              1 Reply Last reply Reply Quote 0
              • Gaspode
                Gaspode @Asgothian last edited by

                @asgothian @arteck

                Da brat mir doch einer einen Storch. Ich hab jetzt nochmal ein Update auf die aktuellle GIT Version gemacht und davor die Zeile "External Converters" in der Konfiguration gelöscht. Es läuft! Auch die Icons sind jetzt wie von @Asgothian angekündigt da.

                Und das Gerät, das in Adapter Version 1.x als externer Konverter betrieben wurde, wird jetzt als "Egony_Flower" erkannt, ganz ohne externen Konverter.

                Also vielen Dank für die Hilfe, wenn mir noch was auffällt, melde ich es hier. Evtl. lässt sich was machen, damit ein (falscher?) externer Konverter nicht die ganze Instanz in den Abgrund reißt. Wenn ihr dazu noch Infos/Tests braucht, sagt einfach Bescheid.

                Asgothian 1 Reply Last reply Reply Quote 0
                • Asgothian
                  Asgothian Developer @Gaspode last edited by Asgothian

                  @gaspode sagte in Tester Zigbee Adapter 3.x gesucht:

                  Also vielen Dank für die Hilfe, wenn mir noch was auffällt, melde ich es hier. Evtl. lässt sich was machen, damit ein (falscher?) externer Konverter nicht die ganze Instanz in den Abgrund reißt. Wenn ihr dazu noch Infos/Tests braucht, sagt einfach Bescheid.

                  Mach mal bitte die folgenden 2 Tests:

                  • Konverter so wie oben gepostet. In der Konfiguration aktiv. Adapter starten
                  • Konverter anpassen, das der icon Entry raus ist, Adapter starten.

                  Das der Sensor jetzt ohne externen Konverter erkannt wird ist kein Wunder - eine der Änderung zwischen 3.0.1 und 3.0.2 RC (Der Git Version) ist das eine neuere ZHC Version genutzt wird. Genau darüber kommen neue Geräte in den Adapter

                  A.

                  Gaspode 2 Replies Last reply Reply Quote 1
                  • Gaspode
                    Gaspode @Asgothian last edited by

                    @asgothian said in Tester Zigbee Adapter 3.x gesucht:

                    Mach mal bitte die folgenden 2 Tests:

                    Konverter so wie oben gepostet. In der Konfiguration aktiv. Adapter starten
                    Konverter anpassen, das der icon Entry raus ist, Adapter starten.

                    Mach ich später auf dem Testsystem, sobald der neue Zigbee USB Stick da ist.

                    1 Reply Last reply Reply Quote 0
                    • Gaspode
                      Gaspode @Asgothian last edited by

                      @asgothian said in Tester Zigbee Adapter 3.x gesucht:

                      Mach mal bitte die folgenden 2 Tests:

                      Konverter so wie oben gepostet. In der Konfiguration aktiv. Adapter starten
                      Konverter anpassen, das der icon Entry raus ist, Adapter starten.

                      Ich hab mal mit Test 2 angefangen. Der Crash ist auch ohne den icon entry reproduzierbar, s. log und Converter File.

                      zigbee_error.log
                      Flower_Neu_mod.js.txt

                      Brauchst du trotzdem den Test mit dem Original Converter File?

                      Asgothian 1 Reply Last reply Reply Quote 0
                      • Asgothian
                        Asgothian Developer @Gaspode last edited by

                        @gaspode war das mit dem Gerât für den der Konverter gemacht ist an dieser Instanz gepaired oder ohne ?

                        Gaspode 1 Reply Last reply Reply Quote 0
                        • Gaspode
                          Gaspode @Asgothian last edited by Gaspode

                          @asgothian said in Tester Zigbee Adapter 3.x gesucht:

                          @gaspode war das mit dem Gerât für den der Konverter gemacht ist an dieser Instanz gepaired oder ohne ?

                          Gerät war gepaired. Ohne Gerät ist soweit ich mich erinnern kann nix passiert.

                          Edit: Gerade nochmal probiert: Mit Converter in der Konfiguration und ohne passendes gepairtes Device startet der Adapter, Log:

                          2025-06-04 16:43:31.811 - info: zigbee.0 (16148) Got terminate signal TERMINATE_YOURSELF
                          2025-06-04 16:43:31.812 - info: zigbee.0 (16148) Halting zigbee adapter. Restart delay is at least 30 seconds.
                          2025-06-04 16:43:31.812 - info: zigbee.0 (16148) cleaning everything up...
                          2025-06-04 16:43:31.813 - info: zigbee.0 (16148) Saved local configuration data
                          2025-06-04 16:43:32.050 - info: zigbee.0 (16148) Closing Zigbee network, 0 seconds remaining
                          2025-06-04 16:43:35.816 - info: zigbee.0 (16148) Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
                          2025-06-04 16:44:10.068 - info: zigbee.0 (38644) starting. Version 3.0.1 (non-npm: ioBroker/ioBroker.zigbee) in C:/ioBroker/Zigbee/node_modules/iobroker.zigbee, node: v20.19.2, js-controller: 7.0.6
                          2025-06-04 16:44:10.081 - info: zigbee.0 (38644) Adapter ready - starting subsystems. Adapter is running in info mode.
                          2025-06-04 16:44:10.082 - warn: zigbee.0 (38644) trying to add "fz = require(../zigbee-herdsman-converters\dist/converters/fromZigbee)" to sandbox
                          2025-06-04 16:44:10.082 - warn: zigbee.0 (38644) trying to add "tz = require(../zigbee-herdsman-converters\dist/converters/toZigbee)" to sandbox
                          2025-06-04 16:44:10.082 - warn: zigbee.0 (38644) trying to add "exposes = require(../zigbee-herdsman-converters\dist/lib/exposes)" to sandbox
                          2025-06-04 16:44:10.083 - warn: zigbee.0 (38644) trying to add "reporting = require(../zigbee-herdsman-converters\dist/lib/reporting)" to sandbox
                          2025-06-04 16:44:10.083 - warn: zigbee.0 (38644) Trying to run sandbox for C:\ioBroker\Zigbee\iobroker-data\zigbee_0\Flower_Neu_mod.js
                          2025-06-04 16:44:10.084 - info: zigbee.0 (38644) Model Egony_Flower defined in external converter C:\ioBroker\Zigbee\iobroker-data\zigbee_0\Flower_Neu_mod.js
                          2025-06-04 16:44:10.084 - info: zigbee.0 (38644) added external converter using addExternalDefinition (0 ms)
                          2025-06-04 16:44:10.085 - info: zigbee.0 (38644) init localConfig
                          2025-06-04 16:44:10.120 - info: zigbee.0 (38644) delete old Backup files. keep only last 10
                          2025-06-04 16:44:10.121 - info: zigbee.0 (38644) --- creating device debug ---
                          2025-06-04 16:44:10.121 - info: zigbee.0 (38644) Autostart Zigbee subsystem
                          2025-06-04 16:44:10.121 - info: zigbee.0 (38644) Starting Adapter npm ...
                          2025-06-04 16:44:10.126 - info: zigbee.0 (38644) Installed Version: ioBroker/ioBroker.zigbee (Converters 23.35.0 Herdsman 4.0.0)
                          2025-06-04 16:44:10.126 - info: zigbee.0 (38644) configured transmit power : normal
                          2025-06-04 16:44:10.126 - info: zigbee.0 (38644) Starting Zigbee-Herdsman
                          2025-06-04 16:44:10.379 - info: zigbee.0 (38644) Zigbee-Herdsman started successfully with Coordinator firmware version: ZStack3x0 : 20210708 (2-1.2.7.1)
                          2025-06-04 16:44:10.379 - info: zigbee.0 (38644) Unable to disable LED, unsupported function.
                          2025-06-04 16:44:10.392 - info: zigbee.0 (38644) 0x08ddebfffeeddb0d (addr 39209): SNZB-02D - SONOFF Temperature and humidity sensor with screen (EndDevice)
                          2025-06-04 16:44:10.392 - info: zigbee.0 (38644) Currently 1 devices are joined:
                          2025-06-04 16:44:10.392 - info: zigbee.0 (38644) Zigbee started
                          2025-06-04 16:44:10.397 - info: zigbee.0 (38644) debug devices set to []
                          
                          1 Reply Last reply Reply Quote 0
                          • Gaspode
                            Gaspode last edited by Gaspode

                            Und noch eine Beobachtung:
                            ich habe jetzt auf einem Testrechner eine neue ioBroker Installation gemacht und den Zigbee Adapter von Github installiert. Angelernt habe ich zum Test eben den Feuchte-Sensor und einen SONOFF SNZB-02D Temperatursensor.
                            Beide Devices werden zwar aktualisiert, die Werte sind aber jetzt nach einigen Stunden immer noch alle Null.
                            Auf meinem produktiven ioBroker werden die Werte der Devices hingegen aktualisiert, so wie es sein soll. Die Devices dort wurden alle unter Version 1.x des Adapters angelernt.
                            Dauert das nach Anlernen der Geräte einfach lange, bis Werte kommen? Oder stimmt was nicht?
                            Ich hab für den Temperatursensor mal auf das Debug Icon geklickt, im Log sehe ich dann:

                            2025-06-04 17:21:57.789 - info: zigbee.0 (25192) debug devices set to ["08ddebfffeeddb0d"]
                            2025-06-04 17:22:10.759 - warn: zigbee.0 (25192) ELEVATED:O01 (1bc7) User state change of state zigbee.0.08ddebfffeeddb0d.temperature_units with value celsius (ack: false) from system.adapter.zigbee.0
                            2025-06-04 17:22:10.760 - warn: zigbee.0 (25192) ELEVATED:O02 (1bc7) Change state 'temperature_units' at device 0x08ddebfffeeddb0d type 'SNZB-02D'
                            2025-06-04 17:22:10.760 - warn: zigbee.0 (25192) ELEVATED:O03 (1bc7) Publishing to 0x08ddebfffeeddb0d of model SNZB-02D with temperature_units
                            2025-06-04 17:22:10.760 - warn: zigbee.0 (25192) ELEVATED:O04 (1bc7) convert temperature_units, "celsius", {} for device 0x08ddebfffeeddb0d with Endpoint temperature_units
                            2025-06-04 17:31:22.592 - warn: zigbee.0 (25192) ELEVATED:I01 (8760) Zigbee Event of Type commandQueryNextImageRequest from device 0x08ddebfffeeddb0d, incoming event: {"type":"commandQueryNextImageRequest","data":{"fieldControl":0,"manufacturerCode":4742,"imageType":2053,"fileVersion":4105},"linkquality":144,"groupID":0,"cluster":"genOta","meta":{"zclTransactionSequenceNumber":28,"frameControl":{"frameType":1,"manufacturerSpecific":false,"direction":0,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                            2025-06-04 17:31:22.593 - warn: zigbee.0 (25192) ELEVATED:NOCONV (8760) No converter available for 'SNZB-02D' '08ddebfffeeddb0d' with cluster 'genOta' and type 'commandQueryNextImageRequest'
                            2025-06-04 17:31:22.593 - warn: zigbee.0 (25192) ELEVATED:I01 (8760) message received '{"linkquality":144}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                            2025-06-04 17:31:22.593 - warn: zigbee.0 (25192) ELEVATED:I02 (8760) value generated '144' from device 08ddebfffeeddb0d for 'Link quality'
                            2025-06-04 17:31:23.032 - warn: zigbee.0 (25192) ELEVATED:SUCCESS (1bc7) convert result {"state":{"temperature_units":"celsius"}} for device 0x08ddebfffeeddb0d
                            2025-06-04 17:31:25.601 - warn: zigbee.0 (25192) ELEVATED:I01 (9321) Zigbee Event of Type commandQueryNextImageRequest from device 0x08ddebfffeeddb0d, incoming event: {"type":"commandQueryNextImageRequest","data":{"fieldControl":0,"manufacturerCode":4742,"imageType":2053,"fileVersion":4105},"linkquality":147,"groupID":0,"cluster":"genOta","meta":{"zclTransactionSequenceNumber":29,"frameControl":{"frameType":1,"manufacturerSpecific":false,"direction":0,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                            2025-06-04 17:31:25.602 - warn: zigbee.0 (25192) ELEVATED:NOCONV (9321) No converter available for 'SNZB-02D' '08ddebfffeeddb0d' with cluster 'genOta' and type 'commandQueryNextImageRequest'
                            2025-06-04 17:31:25.603 - warn: zigbee.0 (25192) ELEVATED:I01 (9321) message received '{"linkquality":147}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                            2025-06-04 17:31:25.603 - warn: zigbee.0 (25192) ELEVATED:I02 (9321) value generated '147' from device 08ddebfffeeddb0d for 'Link quality'
                            2025-06-04 17:31:28.609 - warn: zigbee.0 (25192) ELEVATED:I01 (9ee1) Zigbee Event of Type commandQueryNextImageRequest from device 0x08ddebfffeeddb0d, incoming event: {"type":"commandQueryNextImageRequest","data":{"fieldControl":0,"manufacturerCode":4742,"imageType":2053,"fileVersion":4105},"linkquality":120,"groupID":0,"cluster":"genOta","meta":{"zclTransactionSequenceNumber":30,"frameControl":{"frameType":1,"manufacturerSpecific":false,"direction":0,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                            2025-06-04 17:31:28.611 - warn: zigbee.0 (25192) ELEVATED:NOCONV (9ee1) No converter available for 'SNZB-02D' '08ddebfffeeddb0d' with cluster 'genOta' and type 'commandQueryNextImageRequest'
                            2025-06-04 17:31:28.611 - warn: zigbee.0 (25192) ELEVATED:I01 (9ee1) message received '{"linkquality":120}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                            2025-06-04 17:31:28.611 - warn: zigbee.0 (25192) ELEVATED:I02 (9ee1) value generated '120' from device 08ddebfffeeddb0d for 'Link quality'
                            2025-06-04 17:31:31.620 - warn: zigbee.0 (25192) ELEVATED:I01 (aaa4) Zigbee Event of Type commandQueryNextImageRequest from device 0x08ddebfffeeddb0d, incoming event: {"type":"commandQueryNextImageRequest","data":{"fieldControl":0,"manufacturerCode":4742,"imageType":2053,"fileVersion":4105},"linkquality":150,"groupID":0,"cluster":"genOta","meta":{"zclTransactionSequenceNumber":31,"frameControl":{"frameType":1,"manufacturerSpecific":false,"direction":0,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                            2025-06-04 17:31:31.621 - warn: zigbee.0 (25192) ELEVATED:NOCONV (aaa4) No converter available for 'SNZB-02D' '08ddebfffeeddb0d' with cluster 'genOta' and type 'commandQueryNextImageRequest'
                            2025-06-04 17:31:31.621 - warn: zigbee.0 (25192) ELEVATED:I01 (aaa4) message received '{"linkquality":150}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                            2025-06-04 17:31:31.621 - warn: zigbee.0 (25192) ELEVATED:I02 (aaa4) value generated '150' from device 08ddebfffeeddb0d for 'Link quality'
                            2025-06-04 17:31:34.631 - warn: zigbee.0 (25192) ELEVATED:I01 (b667) Zigbee Event of Type commandQueryNextImageRequest from device 0x08ddebfffeeddb0d, incoming event: {"type":"commandQueryNextImageRequest","data":{"fieldControl":0,"manufacturerCode":4742,"imageType":2053,"fileVersion":4105},"linkquality":147,"groupID":0,"cluster":"genOta","meta":{"zclTransactionSequenceNumber":33,"frameControl":{"frameType":1,"manufacturerSpecific":false,"direction":0,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                            2025-06-04 17:31:34.632 - warn: zigbee.0 (25192) ELEVATED:NOCONV (b667) No converter available for 'SNZB-02D' '08ddebfffeeddb0d' with cluster 'genOta' and type 'commandQueryNextImageRequest'
                            2025-06-04 17:31:34.632 - warn: zigbee.0 (25192) ELEVATED:I01 (b667) message received '{"linkquality":147}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                            2025-06-04 17:31:34.632 - warn: zigbee.0 (25192) ELEVATED:I02 (b667) value generated '147' from device 08ddebfffeeddb0d for 'Link quality'
                            2025-06-04 17:32:00.797 - warn: zigbee.0 (25192) ELEVATED:I01 (1c9d) Zigbee Event of Type commandToggle from device 0x08ddebfffeeddb0d, incoming event: {"type":"commandToggle","data":{},"linkquality":132,"groupID":0,"cluster":"genOnOff","meta":{"zclTransactionSequenceNumber":35,"frameControl":{"frameType":1,"manufacturerSpecific":false,"direction":0,"disableDefaultResponse":false,"reservedBits":0}},"endpoint_id":1}
                            2025-06-04 17:32:00.798 - warn: zigbee.0 (25192) ELEVATED:NOCONV (1c9d) No converter available for 'SNZB-02D' '08ddebfffeeddb0d' with cluster 'genOnOff' and type 'commandToggle'
                            2025-06-04 17:32:00.799 - warn: zigbee.0 (25192) ELEVATED:I01 (1c9d) message received '{"linkquality":132}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                            2025-06-04 17:32:00.799 - warn: zigbee.0 (25192) ELEVATED:I02 (1c9d) value generated '132' from device 08ddebfffeeddb0d for 'Link quality'
                            2025-06-04 17:32:24.184 - warn: zigbee.0 (25192) ELEVATED:I01 (77f8) Zigbee Event of Type commandToggle from device 0x08ddebfffeeddb0d, incoming event: {"type":"commandToggle","data":{},"linkquality":117,"groupID":0,"cluster":"genOnOff","meta":{"zclTransactionSequenceNumber":42,"frameControl":{"frameType":1,"manufacturerSpecific":false,"direction":0,"disableDefaultResponse":false,"reservedBits":0}},"endpoint_id":1}
                            2025-06-04 17:32:24.186 - warn: zigbee.0 (25192) ELEVATED:NOCONV (77f8) No converter available for 'SNZB-02D' '08ddebfffeeddb0d' with cluster 'genOnOff' and type 'commandToggle'
                            2025-06-04 17:32:24.186 - warn: zigbee.0 (25192) ELEVATED:I01 (77f8) message received '{"linkquality":117}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                            2025-06-04 17:32:24.186 - warn: zigbee.0 (25192) ELEVATED:I02 (77f8) value generated '117' from device 08ddebfffeeddb0d for 'Link quality'
                            

                            Die letzten paar Einträge kamen, als ich auf den kleinen Knopf des Sensors gedrückt habe. Die davor spontan.

                            Asgothian 1 Reply Last reply Reply Quote 0
                            • Asgothian
                              Asgothian Developer @Gaspode last edited by

                              @gaspode Lös mal eine Konfiguration über die Kachel aus. Warte bis die Meldung mit dem Timeout kommt, dann trigger den Sensor mit dem Button.

                              A.

                              Gaspode 2 Replies Last reply Reply Quote 0
                              • Gaspode
                                Gaspode @Asgothian last edited by Gaspode

                                @asgothian said in Tester Zigbee Adapter 3.x gesucht:

                                Lös mal eine Konfiguration über die Kachel aus. Warte bis die Meldung mit dem Timeout kommt, dann trigger den Sensor mit dem Button.

                                Ich hatte kurz nachdem ich meinen letzten Beitrag geschrieben habe, ein FW Update angestoßen. Das ist jetzt durch und siehe da, es kommen Werte für den Temperatursensor. Sory, das Update lief schon, als du geschrieben hast, deshalb konnte ich das nicht so testen.

                                Hier das Log:

                                2025-06-04 18:46:59.767  - info: zigbee.0 (25192) Update of '0x08ddebfffeeddb0d' at 99.86%, +- 0 minutes remaining
                                2025-06-04 18:46:59.829  - warn: zigbee.0 (25192) ELEVATED:I01 (c2f5) Zigbee Event of Type commandImageBlockRequest from device 0x08ddebfffeeddb0d, incoming event: {"type":"commandImageBlockRequest","data":{"fieldControl":0,"manufacturerCode":4742,"imageType":2053,"fileVersion":8960,"fileOffset":263800,"maximumDataSize":63},"linkquality":162,"groupID":0,"cluster":"genOta","meta":{"zclTransactionSequenceNumber":2,"frameControl":{"frameType":1,"manufacturerSpecific":false,"direction":0,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                                2025-06-04 18:46:59.831  - warn: zigbee.0 (25192) ELEVATED:NOCONV (c2f5) No converter available for 'SNZB-02D' '08ddebfffeeddb0d' with cluster 'genOta' and type 'commandImageBlockRequest'
                                2025-06-04 18:46:59.831  - warn: zigbee.0 (25192) ELEVATED:I01 (c2f5) message received '{"linkquality":162}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:46:59.831  - warn: zigbee.0 (25192) ELEVATED:I02 (c2f5) value generated '162' from device 08ddebfffeeddb0d for 'Link quality'
                                2025-06-04 18:47:00.329  - warn: zigbee.0 (25192) ELEVATED:I01 (c4e9) Zigbee Event of Type commandImageBlockRequest from device 0x08ddebfffeeddb0d, incoming event: {"type":"commandImageBlockRequest","data":{"fieldControl":0,"manufacturerCode":4742,"imageType":2053,"fileVersion":8960,"fileOffset":263850,"maximumDataSize":63},"linkquality":162,"groupID":0,"cluster":"genOta","meta":{"zclTransactionSequenceNumber":3,"frameControl":{"frameType":1,"manufacturerSpecific":false,"direction":0,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                                2025-06-04 18:47:00.330  - warn: zigbee.0 (25192) ELEVATED:NOCONV (c4e9) No converter available for 'SNZB-02D' '08ddebfffeeddb0d' with cluster 'genOta' and type 'commandImageBlockRequest'
                                2025-06-04 18:47:00.330  - warn: zigbee.0 (25192) ELEVATED:I01 (c4e9) message received '{"linkquality":162}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:47:00.330  - warn: zigbee.0 (25192) ELEVATED:I02 (c4e9) value generated '162' from device 08ddebfffeeddb0d for 'Link quality'
                                2025-06-04 18:47:00.833  - warn: zigbee.0 (25192) ELEVATED:I01 (c6e0) Zigbee Event of Type commandImageBlockRequest from device 0x08ddebfffeeddb0d, incoming event: {"type":"commandImageBlockRequest","data":{"fieldControl":0,"manufacturerCode":4742,"imageType":2053,"fileVersion":8960,"fileOffset":263900,"maximumDataSize":63},"linkquality":162,"groupID":0,"cluster":"genOta","meta":{"zclTransactionSequenceNumber":4,"frameControl":{"frameType":1,"manufacturerSpecific":false,"direction":0,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                                2025-06-04 18:47:00.834  - warn: zigbee.0 (25192) ELEVATED:NOCONV (c6e0) No converter available for 'SNZB-02D' '08ddebfffeeddb0d' with cluster 'genOta' and type 'commandImageBlockRequest'
                                2025-06-04 18:47:00.834  - warn: zigbee.0 (25192) ELEVATED:I01 (c6e0) message received '{"linkquality":162}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:47:00.834  - warn: zigbee.0 (25192) ELEVATED:I02 (c6e0) value generated '162' from device 08ddebfffeeddb0d for 'Link quality'
                                2025-06-04 18:47:01.334  - warn: zigbee.0 (25192) ELEVATED:I01 (c8d6) Zigbee Event of Type commandImageBlockRequest from device 0x08ddebfffeeddb0d, incoming event: {"type":"commandImageBlockRequest","data":{"fieldControl":0,"manufacturerCode":4742,"imageType":2053,"fileVersion":8960,"fileOffset":263950,"maximumDataSize":63},"linkquality":162,"groupID":0,"cluster":"genOta","meta":{"zclTransactionSequenceNumber":5,"frameControl":{"frameType":1,"manufacturerSpecific":false,"direction":0,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                                2025-06-04 18:47:01.336  - warn: zigbee.0 (25192) ELEVATED:NOCONV (c8d6) No converter available for 'SNZB-02D' '08ddebfffeeddb0d' with cluster 'genOta' and type 'commandImageBlockRequest'
                                2025-06-04 18:47:01.336  - warn: zigbee.0 (25192) ELEVATED:I01 (c8d6) message received '{"linkquality":162}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:47:01.336  - warn: zigbee.0 (25192) ELEVATED:I02 (c8d6) value generated '162' from device 08ddebfffeeddb0d for 'Link quality'
                                2025-06-04 18:47:01.839  - warn: zigbee.0 (25192) ELEVATED:I01 (cacf) Zigbee Event of Type commandImageBlockRequest from device 0x08ddebfffeeddb0d, incoming event: {"type":"commandImageBlockRequest","data":{"fieldControl":0,"manufacturerCode":4742,"imageType":2053,"fileVersion":8960,"fileOffset":264000,"maximumDataSize":63},"linkquality":165,"groupID":0,"cluster":"genOta","meta":{"zclTransactionSequenceNumber":6,"frameControl":{"frameType":1,"manufacturerSpecific":false,"direction":0,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                                2025-06-04 18:47:01.840  - warn: zigbee.0 (25192) ELEVATED:NOCONV (cacf) No converter available for 'SNZB-02D' '08ddebfffeeddb0d' with cluster 'genOta' and type 'commandImageBlockRequest'
                                2025-06-04 18:47:01.840  - warn: zigbee.0 (25192) ELEVATED:I01 (cacf) message received '{"linkquality":165}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:47:01.840  - warn: zigbee.0 (25192) ELEVATED:I02 (cacf) value generated '165' from device 08ddebfffeeddb0d for 'Link quality'
                                2025-06-04 18:47:02.338  - warn: zigbee.0 (25192) ELEVATED:I01 (ccc2) Zigbee Event of Type commandImageBlockRequest from device 0x08ddebfffeeddb0d, incoming event: {"type":"commandImageBlockRequest","data":{"fieldControl":0,"manufacturerCode":4742,"imageType":2053,"fileVersion":8960,"fileOffset":264050,"maximumDataSize":63},"linkquality":165,"groupID":0,"cluster":"genOta","meta":{"zclTransactionSequenceNumber":7,"frameControl":{"frameType":1,"manufacturerSpecific":false,"direction":0,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                                2025-06-04 18:47:02.339  - warn: zigbee.0 (25192) ELEVATED:NOCONV (ccc2) No converter available for 'SNZB-02D' '08ddebfffeeddb0d' with cluster 'genOta' and type 'commandImageBlockRequest'
                                2025-06-04 18:47:02.339  - warn: zigbee.0 (25192) ELEVATED:I01 (ccc2) message received '{"linkquality":165}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:47:02.339  - warn: zigbee.0 (25192) ELEVATED:I02 (ccc2) value generated '165' from device 08ddebfffeeddb0d for 'Link quality'
                                2025-06-04 18:47:02.839  - warn: zigbee.0 (25192) ELEVATED:I01 (ceb7) Zigbee Event of Type commandImageBlockRequest from device 0x08ddebfffeeddb0d, incoming event: {"type":"commandImageBlockRequest","data":{"fieldControl":0,"manufacturerCode":4742,"imageType":2053,"fileVersion":8960,"fileOffset":264100,"maximumDataSize":63},"linkquality":165,"groupID":0,"cluster":"genOta","meta":{"zclTransactionSequenceNumber":8,"frameControl":{"frameType":1,"manufacturerSpecific":false,"direction":0,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                                2025-06-04 18:47:02.841  - warn: zigbee.0 (25192) ELEVATED:NOCONV (ceb7) No converter available for 'SNZB-02D' '08ddebfffeeddb0d' with cluster 'genOta' and type 'commandImageBlockRequest'
                                2025-06-04 18:47:02.841  - warn: zigbee.0 (25192) ELEVATED:I01 (ceb7) message received '{"linkquality":165}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:47:02.841  - warn: zigbee.0 (25192) ELEVATED:I02 (ceb7) value generated '165' from device 08ddebfffeeddb0d for 'Link quality'
                                2025-06-04 18:47:03.389  - warn: zigbee.0 (25192) ELEVATED:I01 (d0dd) Zigbee Event of Type commandUpgradeEndRequest from device 0x08ddebfffeeddb0d, incoming event: {"type":"commandUpgradeEndRequest","data":{"status":0,"manufacturerCode":4742,"imageType":2053,"fileVersion":8960},"linkquality":162,"groupID":0,"cluster":"genOta","meta":{"zclTransactionSequenceNumber":9,"frameControl":{"frameType":1,"manufacturerSpecific":false,"direction":0,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                                2025-06-04 18:47:03.390  - warn: zigbee.0 (25192) ELEVATED:NOCONV (d0dd) No converter available for 'SNZB-02D' '08ddebfffeeddb0d' with cluster 'genOta' and type 'commandUpgradeEndRequest'
                                2025-06-04 18:47:03.390  - warn: zigbee.0 (25192) ELEVATED:I01 (d0dd) message received '{"linkquality":162}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:47:03.390  - warn: zigbee.0 (25192) ELEVATED:I02 (d0dd) value generated '162' from device 08ddebfffeeddb0d for 'Link quality'
                                2025-06-04 18:47:03.811  - info: zigbee.0 (25192) Update of '0x08ddebfffeeddb0d' at 100%
                                2025-06-04 18:47:03.834  - warn: zigbee.0 (25192) ELEVATED:I01 (d29a) Zigbee Event of Type raw from device 0x08ddebfffeeddb0d, incoming event: {"type":"raw","data":{"type":"Buffer","data":[13,23,18,10,1,7,23,18,0]},"linkquality":165,"groupID":0,"cluster":"manuSpecificAmazonWWAH","meta":{},"endpoint_id":1}
                                2025-06-04 18:47:03.835  - warn: zigbee.0 (25192) ELEVATED:NOCONV (d29a) No converter available for 'SNZB-02D' '08ddebfffeeddb0d' with cluster 'manuSpecificAmazonWWAH' and type 'raw'
                                2025-06-04 18:47:03.835  - warn: zigbee.0 (25192) ELEVATED:I01 (d29a) message received '{"linkquality":165}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:47:03.835  - warn: zigbee.0 (25192) ELEVATED:I02 (d29a) value generated '165' from device 08ddebfffeeddb0d for 'Link quality'
                                2025-06-04 18:47:18.686  - warn: zigbee.0 (25192) ELEVATED:Ida (0c9e) Device '0x08ddebfffeeddb0d' announced itself
                                2025-06-04 18:47:18.789  - warn: zigbee.0 (25192) ELEVATED:I01 (0d05) Zigbee Event of Type readResponse from device 0x08ddebfffeeddb0d, incoming event: {"type":"readResponse","data":{"dateCode":"20250116","swBuildId":"2.3.0"},"linkquality":165,"groupID":0,"cluster":"genBasic","meta":{"zclTransactionSequenceNumber":68,"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                                2025-06-04 18:47:18.793  - info: zigbee.0 (25192) Finished update of '0x08ddebfffeeddb0d', from '{"softwareBuildID":"1.0.9","dateCode":"20230105"}' to '{"softwareBuildID":"2.3.0","dateCode":"20250116"}'
                                2025-06-04 18:47:18.794  - warn: zigbee.0 (25192) ELEVATED:I01 (0d05) message received '{"linkquality":165}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:47:18.794  - warn: zigbee.0 (25192) ELEVATED:I02 (0d05) value generated '165' from device 08ddebfffeeddb0d for 'Link quality'
                                2025-06-04 18:47:19.697  - warn: zigbee.0 (25192) ELEVATED:I01 (1091) message received '{"available":true}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:47:19.697  - warn: zigbee.0 (25192) ELEVATED:I02 (1091) value generated 'true' from device 08ddebfffeeddb0d for 'Available'
                                2025-06-04 18:47:19.697  - warn: zigbee.0 (25192) ELEVATED:I01 (1091) message received '{"linkquality":10}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:47:19.697  - warn: zigbee.0 (25192) ELEVATED:I02 (1091) value generated '10' from device 08ddebfffeeddb0d for 'Link quality'
                                2025-06-04 18:47:21.137  - warn: zigbee.0 (25192) ELEVATED:I01 (1631) Zigbee Event of Type attributeReport from device 0x08ddebfffeeddb0d, incoming event: {"type":"attributeReport","data":{"batteryPercentageRemaining":200},"linkquality":165,"groupID":0,"cluster":"genPowerCfg","meta":{"zclTransactionSequenceNumber":1,"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                                2025-06-04 18:47:21.140  - warn: zigbee.0 (25192) ELEVATED:I01 (1631) message received '{"linkquality":165}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:47:21.140  - warn: zigbee.0 (25192) ELEVATED:I02 (1631) value generated '165' from device 08ddebfffeeddb0d for 'Link quality'
                                2025-06-04 18:47:21.140  - warn: zigbee.0 (25192) ELEVATED:I01 (1631) message received '{"battery":100}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:47:21.140  - warn: zigbee.0 (25192) ELEVATED:I02 (1631) value generated '100' from device 08ddebfffeeddb0d for 'Battery percent'
                                2025-06-04 18:47:21.142  - warn: zigbee.0 (25192) ELEVATED:I01 (1636) Zigbee Event of Type attributeReport from device 0x08ddebfffeeddb0d, incoming event: {"type":"attributeReport","data":{"measuredValue":5550},"linkquality":162,"groupID":0,"cluster":"msRelativeHumidity","meta":{"zclTransactionSequenceNumber":2,"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                                2025-06-04 18:47:21.142  - warn: zigbee.0 (25192) ELEVATED:I01 (1636) Zigbee Event of Type attributeReport from device 0x08ddebfffeeddb0d, incoming event: {"type":"attributeReport","data":{"measuredValue":2580},"linkquality":162,"groupID":0,"cluster":"msTemperatureMeasurement","meta":{"zclTransactionSequenceNumber":3,"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                                2025-06-04 18:47:21.143  - warn: zigbee.0 (25192) ELEVATED:I01 (1636) message received '{"linkquality":162}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:47:21.144  - warn: zigbee.0 (25192) ELEVATED:I02 (1636) value generated '162' from device 08ddebfffeeddb0d for 'Link quality'
                                2025-06-04 18:47:21.144  - warn: zigbee.0 (25192) ELEVATED:I01 (1636) message received '{"humidity":55.5}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:47:21.144  - warn: zigbee.0 (25192) ELEVATED:I02 (1636) value generated '55.5' from device 08ddebfffeeddb0d for 'Humidity'
                                2025-06-04 18:47:21.144  - warn: zigbee.0 (25192) ELEVATED:I01 (1636) message received '{"linkquality":162}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:47:21.144  - warn: zigbee.0 (25192) ELEVATED:I02 (1636) value generated '162' from device 08ddebfffeeddb0d for 'Link quality'
                                2025-06-04 18:47:21.144  - warn: zigbee.0 (25192) ELEVATED:I01 (1636) message received '{"temperature":25.8}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:47:21.144  - warn: zigbee.0 (25192) ELEVATED:I02 (1636) value generated '25.8' from device 08ddebfffeeddb0d for 'Temperature'
                                2025-06-04 18:47:23.696  - warn: zigbee.0 (25192) ELEVATED:I01 (2030) Zigbee Event of Type attributeReport from device 0x08ddebfffeeddb0d, incoming event: {"type":"attributeReport","data":{"measuredValue":2580},"linkquality":165,"groupID":0,"cluster":"msTemperatureMeasurement","meta":{"zclTransactionSequenceNumber":4,"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":false,"reservedBits":0}},"endpoint_id":1}
                                2025-06-04 18:47:23.698  - warn: zigbee.0 (25192) ELEVATED:I01 (2032) Zigbee Event of Type attributeReport from device 0x08ddebfffeeddb0d, incoming event: {"type":"attributeReport","data":{"measuredValue":5550},"linkquality":162,"groupID":0,"cluster":"msRelativeHumidity","meta":{"zclTransactionSequenceNumber":5,"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":false,"reservedBits":0}},"endpoint_id":1}
                                2025-06-04 18:47:23.699  - warn: zigbee.0 (25192) ELEVATED:I01 (2030) message received '{"linkquality":165}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:47:23.699  - warn: zigbee.0 (25192) ELEVATED:I02 (2030) value generated '165' from device 08ddebfffeeddb0d for 'Link quality'
                                2025-06-04 18:47:23.699  - warn: zigbee.0 (25192) ELEVATED:I01 (2030) message received '{"temperature":25.8}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:47:23.699  - warn: zigbee.0 (25192) ELEVATED:I02 (2030) value generated '25.8' from device 08ddebfffeeddb0d for 'Temperature'
                                2025-06-04 18:47:23.700  - warn: zigbee.0 (25192) ELEVATED:I01 (2032) message received '{"linkquality":162}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:47:23.700  - warn: zigbee.0 (25192) ELEVATED:I02 (2032) value generated '162' from device 08ddebfffeeddb0d for 'Link quality'
                                2025-06-04 18:47:23.700  - warn: zigbee.0 (25192) ELEVATED:I01 (2032) message received '{"humidity":55.5}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:47:23.700  - warn: zigbee.0 (25192) ELEVATED:I02 (2032) value generated '55.5' from device 08ddebfffeeddb0d for 'Humidity'
                                2025-06-04 18:50:59.762  - warn: zigbee.0 (25192) ELEVATED:I01 (6c32) Zigbee Event of Type commandQueryNextImageRequest from device 0x08ddebfffeeddb0d, incoming event: {"type":"commandQueryNextImageRequest","data":{"fieldControl":0,"manufacturerCode":4742,"imageType":2053,"fileVersion":8960},"linkquality":168,"groupID":0,"cluster":"genOta","meta":{"zclTransactionSequenceNumber":6,"frameControl":{"frameType":1,"manufacturerSpecific":false,"direction":0,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                                2025-06-04 18:50:59.764  - warn: zigbee.0 (25192) ELEVATED:NOCONV (6c32) No converter available for 'SNZB-02D' '08ddebfffeeddb0d' with cluster 'genOta' and type 'commandQueryNextImageRequest'
                                2025-06-04 18:50:59.764  - warn: zigbee.0 (25192) ELEVATED:I01 (6c32) message received '{"linkquality":168}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:50:59.764  - warn: zigbee.0 (25192) ELEVATED:I02 (6c32) value generated '168' from device 08ddebfffeeddb0d for 'Link quality'
                                2025-06-04 18:51:02.772  - warn: zigbee.0 (25192) ELEVATED:I01 (77f4) Zigbee Event of Type commandQueryNextImageRequest from device 0x08ddebfffeeddb0d, incoming event: {"type":"commandQueryNextImageRequest","data":{"fieldControl":0,"manufacturerCode":4742,"imageType":2053,"fileVersion":8960},"linkquality":168,"groupID":0,"cluster":"genOta","meta":{"zclTransactionSequenceNumber":7,"frameControl":{"frameType":1,"manufacturerSpecific":false,"direction":0,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                                2025-06-04 18:51:02.774  - warn: zigbee.0 (25192) ELEVATED:NOCONV (77f4) No converter available for 'SNZB-02D' '08ddebfffeeddb0d' with cluster 'genOta' and type 'commandQueryNextImageRequest'
                                2025-06-04 18:51:02.774  - warn: zigbee.0 (25192) ELEVATED:I01 (77f4) message received '{"linkquality":168}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:51:02.774  - warn: zigbee.0 (25192) ELEVATED:I02 (77f4) value generated '168' from device 08ddebfffeeddb0d for 'Link quality'
                                2025-06-04 18:51:05.779  - warn: zigbee.0 (25192) ELEVATED:I01 (83b3) Zigbee Event of Type commandQueryNextImageRequest from device 0x08ddebfffeeddb0d, incoming event: {"type":"commandQueryNextImageRequest","data":{"fieldControl":0,"manufacturerCode":4742,"imageType":2053,"fileVersion":8960},"linkquality":168,"groupID":0,"cluster":"genOta","meta":{"zclTransactionSequenceNumber":8,"frameControl":{"frameType":1,"manufacturerSpecific":false,"direction":0,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                                2025-06-04 18:51:05.781  - warn: zigbee.0 (25192) ELEVATED:NOCONV (83b3) No converter available for 'SNZB-02D' '08ddebfffeeddb0d' with cluster 'genOta' and type 'commandQueryNextImageRequest'
                                2025-06-04 18:51:05.781  - warn: zigbee.0 (25192) ELEVATED:I01 (83b3) message received '{"linkquality":168}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:51:05.781  - warn: zigbee.0 (25192) ELEVATED:I02 (83b3) value generated '168' from device 08ddebfffeeddb0d for 'Link quality'
                                2025-06-04 18:51:08.789  - warn: zigbee.0 (25192) ELEVATED:I01 (8f75) Zigbee Event of Type commandQueryNextImageRequest from device 0x08ddebfffeeddb0d, incoming event: {"type":"commandQueryNextImageRequest","data":{"fieldControl":0,"manufacturerCode":4742,"imageType":2053,"fileVersion":8960},"linkquality":168,"groupID":0,"cluster":"genOta","meta":{"zclTransactionSequenceNumber":9,"frameControl":{"frameType":1,"manufacturerSpecific":false,"direction":0,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                                2025-06-04 18:51:08.790  - warn: zigbee.0 (25192) ELEVATED:NOCONV (8f75) No converter available for 'SNZB-02D' '08ddebfffeeddb0d' with cluster 'genOta' and type 'commandQueryNextImageRequest'
                                2025-06-04 18:51:08.790  - warn: zigbee.0 (25192) ELEVATED:I01 (8f75) message received '{"linkquality":168}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:51:08.790  - warn: zigbee.0 (25192) ELEVATED:I02 (8f75) value generated '168' from device 08ddebfffeeddb0d for 'Link quality'
                                2025-06-04 18:51:11.798  - warn: zigbee.0 (25192) ELEVATED:I01 (9b36) Zigbee Event of Type commandQueryNextImageRequest from device 0x08ddebfffeeddb0d, incoming event: {"type":"commandQueryNextImageRequest","data":{"fieldControl":0,"manufacturerCode":4742,"imageType":2053,"fileVersion":8960},"linkquality":168,"groupID":0,"cluster":"genOta","meta":{"zclTransactionSequenceNumber":10,"frameControl":{"frameType":1,"manufacturerSpecific":false,"direction":0,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                                2025-06-04 18:51:11.800  - warn: zigbee.0 (25192) ELEVATED:NOCONV (9b36) No converter available for 'SNZB-02D' '08ddebfffeeddb0d' with cluster 'genOta' and type 'commandQueryNextImageRequest'
                                2025-06-04 18:51:11.800  - warn: zigbee.0 (25192) ELEVATED:I01 (9b36) message received '{"linkquality":168}' from device 08ddebfffeeddb0d type 'SNZB-02D'
                                2025-06-04 18:51:11.800  - warn: zigbee.0 (25192) ELEVATED:I02 (9b36) value generated '168' from device 08ddebfffeeddb0d for 'Link quality'
                                

                                Leider gibt es für den Feuchtesensor kein Update bzw. das Gerät unterstützt anscheinend kein OTA Update.

                                1 Reply Last reply Reply Quote 0
                                • Gaspode
                                  Gaspode @Asgothian last edited by Gaspode

                                  @asgothian said in Tester Zigbee Adapter 3.x gesucht:

                                  Lös mal eine Konfiguration über die Kachel aus. Warte bis die Meldung mit dem Timeout kommt, dann trigger den Sensor mit dem Button.

                                  Also am Bodenfeuchte-Sensor (der mit dem ehemals externen Konverter) hat dieses Vorgehen anscheinend geholfen. Kann aber auch Zufall sein. Ist halt immer schwer zu sagen.

                                  Zum Verhalten des SONOFF SNZB-02D Temperatursensors nach Anlernen und vor Software Update: Ich hab noch einen in Originalverpackung, der zum gleichen Zeitpunkt wie der andere gekauft wurde. Bringt es was, wenn ich mit dem nochmal teste? Was sollte ich dann an Debug Einstellungen vornehmen, damit ihr was damit anfangen könnt?

                                  Asgothian 1 Reply Last reply Reply Quote 0
                                  • Asgothian
                                    Asgothian Developer @Gaspode last edited by

                                    @gaspode sagte in Tester Zigbee Adapter 3.x gesucht:

                                    @asgothian said in Tester Zigbee Adapter 3.x gesucht:

                                    Lös mal eine Konfiguration über die Kachel aus. Warte bis die Meldung mit dem Timeout kommt, dann trigger den Sensor mit dem Button.

                                    Also am Bodenfeuchte-Sensor (der mit dem ehemals externen Konverter) hat dieses Vorgehen anscheinend geholfen. Kann aber auch Zufall sein. Ist halt immer schwer zu sagen.

                                    Zum Verhalten des SONOFF SNZB-02D Temperatursensors nach Anlernen und vor Software Update: Ich hab noch einen in Originalverpackung, der zum gleichen Zeitpunkt wie der andere gekauft wurde. Bringt es was, wenn ich mit dem nochmal teste? Was sollte ich dann an Debug Einstellungen vornehmen, damit ihr was damit anfangen könnt?

                                    Zufall sollte das nicht sein - siehe diesen Post zum Thema Konfiguration etc. Zufall ist eher das die Konfiguration beim Anlernen des Sensors nicht erfolgt ist.

                                    Was du testen kannst:

                                    • den aktiven Sonoff Sensor aus dem Netz werfen
                                    • den Sensor zurück setzen
                                    • den Sensor neu anlernen.

                                    In dieser Kette wird er

                                    • die Konfiguration verlieren
                                    • kein Firmware-Update anstossen, und damit 'normal' dem Netz beitreten
                                    • dann hoffentlich durch ein reconfigure nach diesem Muster Daten senden.

                                    Der gleiche Test mit dem neuen Sensor ist eher nicht interessant - ich gehe davon aus das auch dieser sich ein Firmware-Update ziehen wird.

                                    Das ist einer der Punkte dem ich noch nachgehen muss - warum beim Start des Herdsman und /oder beim Anlernen automatisch ein Firmware-Update angestossen wird.

                                    Gaspode 2 Replies Last reply Reply Quote 1
                                    • Gaspode
                                      Gaspode @Asgothian last edited by Gaspode

                                      @asgothian said in Tester Zigbee Adapter 3.x gesucht:

                                      Das ist einer der Punkte dem ich noch nachgehen muss - warum beim Start des Herdsman und /oder beim Anlernen automatisch ein Firmware-Update angestossen wird.

                                      Nur, damit wir nicht aneinander vorbei reden: Das FW Update wurde nicht automatisch gemacht, das habe ich veranlasst. Erst "Prüfen" im Adapter gedrückt, dann auf das Update Icon beim Device. Und erst dann kamen die Daten.

                                      @asgothian said in Tester Zigbee Adapter 3.x gesucht:

                                      Was du testen kannst:

                                      den aktiven Sonoff Sensor aus dem Netz werfen
                                      den Sensor zurück setzen
                                      den Sensor neu anlernen.

                                      Heißt "aus dem Netz werfen" das Delete Icon auf der Device Kachel drücken?
                                      Das hab ich jetzt gemacht. In der Anleitung des Devices steht nix davon, wie man es zurück setzen kann. Ich hab jetzt mal den einzigen Button für >10 Sekunden gedrückt und anschließend kurz die Batterie raus genommen.
                                      Nach dem Neu Anlernen waren die Werte sofort da.

                                      Edit:
                                      @asgothian said in Tester Zigbee Adapter 3.x gesucht:

                                      siehe diesen Post zum Thema Konfiguration etc.

                                      Ach ja, und Danke für die Erklärung.

                                      1 Reply Last reply Reply Quote 1
                                      • Gaspode
                                        Gaspode @Asgothian last edited by Gaspode

                                        @asgothian

                                        Und noch eine Beobachtung, da bin ich mir aber nicht sicher, ob das Verhalten nicht schon in Version 1 ähnlich war und es in Version 3 jetzt durch die Ausgabe von Fehlermeldungen eher auffällt.

                                        Wenn ich in meinem Produktivsystem die Map generieren lasse, bekomme ich 5 Fehler gemeldet:

                                        Map generation messages
                                        Failed to execute LQI for '0x00124bXXXXXXXXXX (undefined') : Timeout.           --> Coordinator
                                        Failed to collect routing table for '0xa4c137XXXXXXXXXX (TS011F') : Timeout     --> Steckdose
                                        Failed to collect routing table for '0xa4c138XXXXXXXXXX (TS011F') : Timeout     --> Steckdose
                                        Failed to collect routing table for '0x00124bXXXXXXXXXX (undefined') : Timeout  --> Coordinator
                                        Failed to collect routing table for '0xa4c139XXXXXXXXXX (TS011F') : Timeout     --> Steckdoes
                                        

                                        Das erste ist der Coordinator, die anderen Lidl Schaltsteckdosen des Typs Lidl HG08673. Von denen hab ich genau drei im Netz. Ich hab noch zwei weitere Steckdosen von Lidl, allerdings Lidl HG06337. Die tauchen nicht auf. In der Map selbst werden Verbindungen der drei Steckdosen angezeigt. Rekonfigurieren der Steckdosen funktioniert sofort, behebt den Effekt aber nicht.

                                        Allerdings gibt es 4 Devices, die in der Map rot und nicht verbunden angezeigt werden. Diese funktionieren aber und von der Lage her es ist sehr wahrscheinlich, dass sie entweder direkt am Coordinator oder an einer der drei Steckdosen hängen.
                                        Bei diesen Devices handelt es sich um zwei Aqara SJCGQ11LM, einen Tuya TS0042 und zwei Aqara WSDCGQ11LM. Alle lassen sich rekonfigurieren, alle funktionieren und von allen Typen bis auf den Tuya TS0042 habe ich noch weitere Devices im Netz.

                                        Ist das für den Test interessant? Wenn du noch was brauchst, sag Bescheid.

                                        Edit: Ach ja, Coordinator:

                                            type:ZStack3x0
                                            version:2-1.2.7.1.
                                            revision:20210708
                                            port:COM4
                                            channel:11
                                        

                                        Es handelt sich um diesen Stick: https://www.amazon.de/dp/B09KXTCMSC

                                        arteck 1 Reply Last reply Reply Quote 0
                                        • arteck
                                          arteck Developer Most Active @Gaspode last edited by

                                          @gaspode sagte in Tester Zigbee Adapter 3.x gesucht:

                                          20210708

                                          bissel alt..

                                          Gaspode 1 Reply Last reply Reply Quote 0
                                          • Gaspode
                                            Gaspode @arteck last edited by Gaspode

                                            @arteck said in Tester Zigbee Adapter 3.x gesucht:

                                            bissel alt..

                                            Und das ist ein Problem? Ich hab mich bisher noch nicht an ein Update ran getraut.

                                            Der zweite, den ich diese Woche bestellt habe, ist übrigens auf dem gleichen Stand. 😔

                                            Edit: Nur damit ich nicht missverstanden werde: Ich will beim Testen helfen, nicht jemandem auf die Nerven gehen. Prinzipiell läuft der Adapter rund und unter normalen Umständen, würde ich jetzt einfach die Finger davon lassen. 😉

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            915
                                            Online

                                            31.7k
                                            Users

                                            79.7k
                                            Topics

                                            1.3m
                                            Posts

                                            zigbee zigbee adapter
                                            20
                                            124
                                            6088
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo