    This topic has been deleted. Only users with topic management privileges can see it.
    • arteck
      arteck Developer Most Active @Gaspode last edited by

      @gaspode sagte in Tester Zigbee Adapter 3.x gesucht:

      20210708

      bissel alt..

      Gaspode 1 Reply Last reply Reply Quote 0
      • Gaspode
        Gaspode @arteck last edited by Gaspode

        @arteck said in Tester Zigbee Adapter 3.x gesucht:

        bissel alt..

        Und das ist ein Problem? Ich hab mich bisher noch nicht an ein Update ran getraut.

        Der zweite, den ich diese Woche bestellt habe, ist übrigens auf dem gleichen Stand. 😔

        Edit: Nur damit ich nicht missverstanden werde: Ich will beim Testen helfen, nicht jemandem auf die Nerven gehen. Prinzipiell läuft der Adapter rund und unter normalen Umständen, würde ich jetzt einfach die Finger davon lassen. 😉

        1 Reply Last reply Reply Quote 0
        • Gaspode
          Gaspode last edited by Gaspode

          OK, ich habe jetzt zunächst auf meinem kleinen Testsystem mit 2 Devices die Coordinator Software auf den aktuellen Stand gebracht.

              type:ZStack3x0
              version:2-1.2.7.1.
              revision:20240710
              port:COM11
              channel:20
          

          Nach dem Neustart wurden zwar beide Geräte angezeigt, waren aber disconnected. Nach etwa drei Minuten hab ich den Adapter neu gestartet. Leider auch keine Änderung. Nach dem Neu Anlernen sind die beiden Geräte jetzt wieder connected und liefern Daten. Ich dachte iegentlich, der Adapter kümmert sich darum, dass die Geräte nach Coordinator Update wieder automatisch am Coordinator angemeldet werden. Oder hab ich da was falsch verstanden?

          Edit: Ach ja, ein Log gibt es auch:

          2025-06-07 09:55:11.516 - info: host.Zigbee "system.adapter.zigbee.0" enabled
          2025-06-07 09:55:11.697 - info: host.Zigbee instance system.adapter.zigbee.0 in version "3.0.1" (non-npm: ioBroker/ioBroker.zigbee) started with pid 16772
          2025-06-07 09:55:12.720 - info: zigbee.0 (16772) starting. Version 3.0.1 (non-npm: ioBroker/ioBroker.zigbee) in C:/ioBroker/Zigbee/node_modules/iobroker.zigbee, node: v20.19.2, js-controller: 7.0.6
          2025-06-07 09:55:12.732 - info: zigbee.0 (16772) Adapter ready - starting subsystems. Adapter is running in info mode.
          2025-06-07 09:55:12.733 - info: zigbee.0 (16772) init localConfig
          2025-06-07 09:55:12.769 - info: zigbee.0 (16772) delete old Backup files. keep only last 10
          2025-06-07 09:55:12.770 - info: zigbee.0 (16772) --- creating device debug ---
          2025-06-07 09:55:12.770 - info: zigbee.0 (16772) Autostart Zigbee subsystem
          2025-06-07 09:55:12.771 - info: zigbee.0 (16772) Starting Adapter npm ...
          2025-06-07 09:55:12.775 - info: zigbee.0 (16772) Installed Version: ioBroker/ioBroker.zigbee (Converters 23.35.0 Herdsman 4.0.0)
          2025-06-07 09:55:12.775 - info: zigbee.0 (16772) configured transmit power : normal
          2025-06-07 09:55:12.775 - info: zigbee.0 (16772) Starting Zigbee-Herdsman
          2025-06-07 09:55:23.896 - info: zigbee.0 (16772) List of port: [{"path":"COM1","manufacturer":"(Standardanschlusstypen)","pnpId":"ACPI\\PNP0501\\0","friendlyName":"Kommunikationsanschluss (COM1)"},{"path":"COM11","manufacturer":"Silicon Labs","serialNumber":"DEDF4C6EF26BEF119385A3ADC169B110","pnpId":"USB\\VID_10C4&PID_EA60\\DEDF4C6EF26BEF119385A3ADC169B110","locationId":"Port_#0003.Hub_#0004","friendlyName":"Silicon Labs CP210x USB to UART Bridge (COM11)","vendorId":"10C4","productId":"EA60"}]
          2025-06-07 09:55:31.535 - info: zigbee.0 (16772) List of port: [{"path":"COM1","manufacturer":"(Standardanschlusstypen)","pnpId":"ACPI\\PNP0501\\0","friendlyName":"Kommunikationsanschluss (COM1)"},{"path":"COM11","manufacturer":"Silicon Labs","serialNumber":"DEDF4C6EF26BEF119385A3ADC169B110","pnpId":"USB\\VID_10C4&PID_EA60\\DEDF4C6EF26BEF119385A3ADC169B110","locationId":"Port_#0003.Hub_#0004","friendlyName":"Silicon Labs CP210x USB to UART Bridge (COM11)","vendorId":"10C4","productId":"EA60"}]
          2025-06-07 09:55:40.224 - info: zigbee.0 (16772) Zigbee-Herdsman started successfully with Coordinator firmware version: ZStack3x0 : 20240710 (2-1.2.7.1)
          2025-06-07 09:55:40.232 - info: zigbee.0 (16772) Unable to disable LED, unsupported function.
          2025-06-07 09:55:40.232 - info: zigbee.0 (16772) No devices are currently joined.
          2025-06-07 09:55:40.233 - info: zigbee.0 (16772) Zigbee started
          2025-06-07 09:55:42.226 - info: zigbee.0 (16772) List of port: [{"path":"COM1","manufacturer":"(Standardanschlusstypen)","pnpId":"ACPI\\PNP0501\\0","friendlyName":"Kommunikationsanschluss (COM1)"},{"path":"COM11","manufacturer":"Silicon Labs","serialNumber":"DEDF4C6EF26BEF119385A3ADC169B110","pnpId":"USB\\VID_10C4&PID_EA60\\DEDF4C6EF26BEF119385A3ADC169B110","locationId":"Port_#0003.Hub_#0004","friendlyName":"Silicon Labs CP210x USB to UART Bridge (COM11)","vendorId":"10C4","productId":"EA60"}]
          2025-06-07 09:55:49.875 - info: zigbee.0 (16772) Collecting Map Data
          2025-06-07 09:55:49.891 - info: zigbee.0 (16772) Map data collection complete
          2025-06-07 09:55:51.670 - info: zigbee.0 (16772) Collecting Map Data
          2025-06-07 09:55:51.684 - info: zigbee.0 (16772) Map data collection complete
          2025-06-07 09:55:54.405 - info: zigbee.0 (16772) Collecting Map Data
          2025-06-07 09:55:54.425 - info: zigbee.0 (16772) Map data collection complete
          2025-06-07 09:55:56.160 - info: zigbee.0 (16772) Collecting Map Data
          2025-06-07 09:55:56.174 - info: zigbee.0 (16772) Map data collection complete
          2025-06-07 09:55:56.818 - info: zigbee.0 (16772) Collecting Map Data
          2025-06-07 09:55:56.832 - info: zigbee.0 (16772) Map data collection complete
          2025-06-07 09:55:57.414 - info: zigbee.0 (16772) Collecting Map Data
          2025-06-07 09:55:57.430 - info: zigbee.0 (16772) Map data collection complete
          2025-06-07 09:55:57.914 - info: zigbee.0 (16772) Collecting Map Data
          2025-06-07 09:55:57.928 - info: zigbee.0 (16772) Map data collection complete
          2025-06-07 09:55:58.349 - info: zigbee.0 (16772) Collecting Map Data
          2025-06-07 09:55:58.364 - info: zigbee.0 (16772) Map data collection complete
          2025-06-07 09:56:14.323 - warn: zigbee.0 (16772) Blocked interview for 'undefined' because the network is closed
          2025-06-07 09:56:32.079 - info: zigbee.0 (16772) List of port: [{"path":"COM1","manufacturer":"(Standardanschlusstypen)","pnpId":"ACPI\\PNP0501\\0","friendlyName":"Kommunikationsanschluss (COM1)"},{"path":"COM11","manufacturer":"Silicon Labs","serialNumber":"DEDF4C6EF26BEF119385A3ADC169B110","pnpId":"USB\\VID_10C4&PID_EA60\\DEDF4C6EF26BEF119385A3ADC169B110","locationId":"Port_#0003.Hub_#0004","friendlyName":"Silicon Labs CP210x USB to UART Bridge (COM11)","vendorId":"10C4","productId":"EA60"}]
          2025-06-07 09:56:49.892 - info: zigbee.0 (16772) List of port: [{"path":"COM1","manufacturer":"(Standardanschlusstypen)","pnpId":"ACPI\\PNP0501\\0","friendlyName":"Kommunikationsanschluss (COM1)"},{"path":"COM11","manufacturer":"Silicon Labs","serialNumber":"DEDF4C6EF26BEF119385A3ADC169B110","pnpId":"USB\\VID_10C4&PID_EA60\\DEDF4C6EF26BEF119385A3ADC169B110","locationId":"Port_#0003.Hub_#0004","friendlyName":"Silicon Labs CP210x USB to UART Bridge (COM11)","vendorId":"10C4","productId":"EA60"}]
          2025-06-07 09:57:00.864 - info: zigbee.0 (16772) Collecting Map Data
          2025-06-07 09:57:24.458 - error: zigbee.0 (16772) Failed to interview '0x08ddebfffeeddb0d', device has not successfully been paired. Try again !!!!!!!!!!
          2025-06-07 09:57:43.318 - warn: zigbee.0 (16772) Blocked interview for 'undefined' because the network is closed
          2025-06-07 09:57:52.576 - info: zigbee.0 (16772) List of port: [{"path":"COM1","manufacturer":"(Standardanschlusstypen)","pnpId":"ACPI\\PNP0501\\0","friendlyName":"Kommunikationsanschluss (COM1)"},{"path":"COM11","manufacturer":"Silicon Labs","serialNumber":"DEDF4C6EF26BEF119385A3ADC169B110","pnpId":"USB\\VID_10C4&PID_EA60\\DEDF4C6EF26BEF119385A3ADC169B110","locationId":"Port_#0003.Hub_#0004","friendlyName":"Silicon Labs CP210x USB to UART Bridge (COM11)","vendorId":"10C4","productId":"EA60"}]
          2025-06-07 09:58:04.417 - info: host.Zigbee stopInstance system.adapter.zigbee.0 (force=false, process=true)
          2025-06-07 09:58:04.418 - info: host.Zigbee stopInstance system.adapter.zigbee.0 send kill signal
          2025-06-07 09:58:04.413 - info: zigbee.0 (16772) Got terminate signal TERMINATE_YOURSELF
          2025-06-07 09:58:04.414 - info: zigbee.0 (16772) Halting zigbee adapter. Restart delay is at least 30 seconds.
          2025-06-07 09:58:04.414 - info: zigbee.0 (16772) cleaning everything up...
          2025-06-07 09:58:04.415 - info: zigbee.0 (16772) Saved local configuration data
          2025-06-07 09:58:04.645 - info: zigbee.0 (16772) Closing Zigbee network, 0 seconds remaining
          2025-06-07 09:58:08.425 - info: zigbee.0 (16772) Terminated (ADAPTER_REQUESTED_TERMINATION): Without reason
          2025-06-07 09:58:08.974 - info: host.Zigbee instance system.adapter.zigbee.0 terminated with code 11 (ADAPTER_REQUESTED_TERMINATION)
          2025-06-07 09:58:41.642 - info: host.Zigbee instance system.adapter.zigbee.0 in version "3.0.1" (non-npm: ioBroker/ioBroker.zigbee) started with pid 34832
          2025-06-07 09:58:42.673 - info: zigbee.0 (34832) starting. Version 3.0.1 (non-npm: ioBroker/ioBroker.zigbee) in C:/ioBroker/Zigbee/node_modules/iobroker.zigbee, node: v20.19.2, js-controller: 7.0.6
          2025-06-07 09:58:42.685 - info: zigbee.0 (34832) Adapter ready - starting subsystems. Adapter is running in info mode.
          2025-06-07 09:58:42.686 - info: zigbee.0 (34832) init localConfig
          2025-06-07 09:58:42.722 - info: zigbee.0 (34832) delete old Backup files. keep only last 10
          2025-06-07 09:58:42.723 - info: zigbee.0 (34832) --- creating device debug ---
          2025-06-07 09:58:42.723 - info: zigbee.0 (34832) Autostart Zigbee subsystem
          2025-06-07 09:58:42.724 - info: zigbee.0 (34832) Starting Adapter npm ...
          2025-06-07 09:58:42.728 - info: zigbee.0 (34832) Installed Version: ioBroker/ioBroker.zigbee (Converters 23.35.0 Herdsman 4.0.0)
          2025-06-07 09:58:42.728 - info: zigbee.0 (34832) configured transmit power : normal
          2025-06-07 09:58:42.728 - info: zigbee.0 (34832) Starting Zigbee-Herdsman
          2025-06-07 09:58:42.935 - info: zigbee.0 (34832) Zigbee-Herdsman started successfully with Coordinator firmware version: ZStack3x0 : 20240710 (2-1.2.7.1)
          2025-06-07 09:58:42.936 - info: zigbee.0 (34832) Unable to disable LED, unsupported function.
          2025-06-07 09:58:42.983 - info: zigbee.0 (34832) 0x08ddebfffeeddb0d (addr 7386): Unsupported (model undefined)(Unknown)
          2025-06-07 09:58:42.983 - info: zigbee.0 (34832) Currently 1 devices are joined:
          2025-06-07 09:58:42.983 - info: zigbee.0 (34832) Zigbee started
          2025-06-07 09:58:42.987 - warn: zigbee.0 (34832) download icon undefined for undefined Device not available. Check your devices.
          2025-06-07 09:58:42.990 - warn: zigbee.0 (34832) Device 0x08ddebfffeeddb0d "undefined" not found.
          2025-06-07 09:59:16.469 - info: zigbee.0 (34832) List of port: [{"path":"COM1","manufacturer":"(Standardanschlusstypen)","pnpId":"ACPI\\PNP0501\\0","friendlyName":"Kommunikationsanschluss (COM1)"},{"path":"COM11","manufacturer":"Silicon Labs","serialNumber":"DEDF4C6EF26BEF119385A3ADC169B110","pnpId":"USB\\VID_10C4&PID_EA60\\DEDF4C6EF26BEF119385A3ADC169B110","locationId":"Port_#0003.Hub_#0004","friendlyName":"Silicon Labs CP210x USB to UART Bridge (COM11)","vendorId":"10C4","productId":"EA60"}]
          2025-06-07 09:59:27.693 - info: zigbee.0 (34832) Opening zigbee Network for 60 seconds
          2025-06-07 09:59:33.296 - info: zigbee.0 (34832) Device '0x08ddebfffeeddb0d' left the network
          2025-06-07 09:59:33.297 - info: zigbee.0 (34832) debug devices set to []
          2025-06-07 09:59:33.307 - info: history.0 (31492) disabled logging of zigbee.0.08ddebfffeeddb0d.humidity
          2025-06-07 09:59:33.313 - info: history.0 (31492) disabled logging of zigbee.0.08ddebfffeeddb0d.temperature
          2025-06-07 09:59:39.637 - info: zigbee.0 (34832) Starting interview of '0x08ddebfffeeddb0d'
          2025-06-07 09:59:41.686 - info: zigbee.0 (34832) Device '0x08ddebfffeeddb0d' announced itself
          2025-06-07 09:59:49.789 - info: zigbee.0 (34832) Device '0x08ddebfffeeddb0d' left the network
          2025-06-07 09:59:53.298 - info: zigbee.0 (34832) Starting interview of '0x08ddebfffeeddb0d'
          2025-06-07 09:59:55.322 - info: zigbee.0 (34832) Device '0x08ddebfffeeddb0d' announced itself
          2025-06-07 10:00:14.189 - info: zigbee.0 (34832) Starting interview of '0x00124b00272cefda'
          2025-06-07 10:00:14.420 - warn: zigbee.0 (34832) Device 0x00124b00272cefda "Egony_Flower" not found.
          2025-06-07 10:00:15.210 - info: zigbee.0 (34832) Successfully interviewed '0x08ddebfffeeddb0d', device has successfully been paired
          2025-06-07 10:00:15.210 - info: zigbee.0 (34832) Device '0x08ddebfffeeddb0d' is supported, identified as: SONOFF Temperature and humidity sensor with screen (SNZB-02D)
          2025-06-07 10:00:15.715 - info: zigbee.0 (34832) Successfully interviewed '0x08ddebfffeeddb0d', device has successfully been paired
          2025-06-07 10:00:15.715 - info: zigbee.0 (34832) Device '0x08ddebfffeeddb0d' is supported, identified as: SONOFF Temperature and humidity sensor with screen (SNZB-02D)
          2025-06-07 10:00:15.802 - info: zigbee.0 (34832) Successfully interviewed '0x00124b00272cefda', device has successfully been paired
          2025-06-07 10:00:15.802 - info: zigbee.0 (34832) Device '0x00124b00272cefda' is supported, identified as: EFEKTA Soil moisture sensor Egony_Flower, mod DIYRuZ Flower (Egony_Flower)
          2025-06-07 10:00:20.265 - info: zigbee.0 (34832) Device '0x00124b00272cefda' left the network
          2025-06-07 10:00:20.272 - info: history.0 (31492) disabled logging of zigbee.0.00124b00272cefda.illuminance_raw
          2025-06-07 10:00:20.280 - info: history.0 (31492) disabled logging of zigbee.0.00124b00272cefda.soil_moisture
          2025-06-07 10:00:27.702 - info: zigbee.0 (34832) Closing Zigbee network, 1 seconds remaining
          2025-06-07 10:00:33.594 - info: zigbee.0 (34832) Opening zigbee Network for 60 seconds
          2025-06-07 10:00:47.115 - info: zigbee.0 (34832) Starting interview of '0x00124b00272cefda'
          2025-06-07 10:00:47.886 - info: zigbee.0 (34832) Device '0x00124b00272cefda' announced itself
          2025-06-07 10:00:49.266 - info: zigbee.0 (34832) Successfully interviewed '0x00124b00272cefda', device has successfully been paired
          2025-06-07 10:00:49.266 - info: zigbee.0 (34832) Device '0x00124b00272cefda' is supported, identified as: EFEKTA Soil moisture sensor Egony_Flower, mod DIYRuZ Flower (Egony_Flower)
          2025-06-07 10:01:06.701 - info: zigbee.0 (34832) Configuring 0x08ddebfffeeddb0d SNZB-02D
          2025-06-07 10:01:15.575 - info: zigbee.0 (34832) DeviceConfigure successful 0x08ddebfffeeddb0d SNZB-02D
          2025-06-07 10:01:28.199 - info: zigbee.0 (34832) Configuring 0x00124b00272cefda Egony_Flower
          2025-06-07 10:01:33.602 - info: zigbee.0 (34832) Closing Zigbee network, 1 seconds remaining
          2025-06-07 10:01:35.336 - info: zigbee.0 (34832) DeviceConfigure successful 0x00124b00272cefda Egony_Flower
          2025-06-07 10:01:46.561 - info: zigbee.0 (34832) Collecting Map Data
          2025-06-07 10:01:46.580 - info: zigbee.0 (34832) Map data collection complete
          2025-06-07 10:02:05.781 - info: zigbee.0 (34832) List of port: [{"path":"COM1","manufacturer":"(Standardanschlusstypen)","pnpId":"ACPI\\PNP0501\\0","friendlyName":"Kommunikationsanschluss (COM1)"},{"path":"COM11","manufacturer":"Silicon Labs","serialNumber":"DEDF4C6EF26BEF119385A3ADC169B110","pnpId":"USB\\VID_10C4&PID_EA60\\DEDF4C6EF26BEF119385A3ADC169B110","locationId":"Port_#0003.Hub_#0004","friendlyName":"Silicon Labs CP210x USB to UART Bridge (COM11)","vendorId":"10C4","productId":"EA60"}]
          2025-06-07 10:02:25.237 - info: zigbee.0 (34832) Device '0x00124b00272cefda' announced itself
          2025-06-07 10:02:53.358 - info: zigbee.0 (34832) Device '0x00124b00272cefda' announced itself
          
          
          Asgothian 1 Reply Last reply Reply Quote 0
          • Asgothian
            Asgothian Developer @Gaspode last edited by Asgothian

            @gaspode sagte in Tester Zigbee Adapter 3.x gesucht:

            Ich dachte iegentlich, der Adapter kümmert sich darum, dass die Geräte nach Coordinator Update wieder automatisch am Coordinator angemeldet werden. Oder hab ich da was falsch verstanden?

            Das ist von Koordinator zu Koordinator unterschiedlich. Im Normalfall reicht es, das Netzwerk zu öffnen und die Geräte zu triggern, so das sie sich verbinden. Gegebenenfalls ist eine Neukonfiguration notwendig.

            Insbesondere in der Kombination CC2531 und Aufsetzen des Netzwerks mit Adapter 2.0.5 kann es passieren das sich die effektive IEEE des Netzes beim Firmware-Update ändert was zu einem erzwungenen Neuanlernen führt.

            A.

            Gaspode 1 Reply Last reply Reply Quote 0
            • Gaspode
              Gaspode @Asgothian last edited by

              @asgothian said in Tester Zigbee Adapter 3.x gesucht:

              Das ist von Koordinator zu Koordinator unterschiedlich. Im Normalfall reicht es, das Netzwerk zu öffnen und die Geräte zu triggern, so das sie sich verbinden. Gegebenenfalls ist eine Neukonfiguration notwendig.
              Insbesondere in der Kombination CC2531 und Aufsetzen des Netzwerks mit Adapter 2.0.5 kann es passieren das sich die effektive IEEE des Netzes beim Firmware-Update ändert was zu einem erzwungenen Neuanlernen führt.

              In meinem Fall ist es ja ein den Sonoff CC2652P. Das Zigbee Netzwerk habe ich vorgestern auf einem neu installierten ioBroker und einem neu installierten Zigbee Adapter auf Github Stand (also V3) angelegt und die beiden Geräte neu angelernt. Jetzt habe ich den Coordinator auf die aktuelle FW gehoben. Und anschließend waren die Geräte nicht mehr verbunden. Dazu hab ich oben das Log gepostet, falls das interessant sein sollte.

              Wie gesagt: Ich sage das im Zusammenhang mit dem Testaufruf der V3. Mein Produktivsystem läuft ja unter V3 stabil.

              Und noch eine Beobachtung (unter Windows):

              In der Adpaterkonfiguration unter Hardware:
              Zunächst halte ich das Zigbee Subsystem an, das klappt. Der Druck auf den Test-Butten führt aber zu einem Fehler:

              stopping zigbee-herdsman
              Closing network.
              herdsman stopped !
              reading access rights for COM11
              Error: unable to access COM11 : ENOENT: no such file or directory, access 'C:\ioBroker\Zigbee\node_modules\iobroker.zigbee\COM11'
              
              Asgothian 2 Replies Last reply Reply Quote 0
              • Asgothian
                Asgothian Developer @Gaspode last edited by

                @gaspode sagte in Tester Zigbee Adapter 3.x gesucht:

                Und noch eine Beobachtung (unter Windows):

                das muss ich mir anschauen - offensichtlich wird da etwas versucht was unter Windows so nicht geht.

                Ich müsste noch wissen welchen Button du nutzt ?

                test port
                test_port.png
                oder start / stop ?
                start_stop.png

                Sofern der Fehler nur bei test port auftritt ist das unkritisch. Diese Option ist primär für Netzwerk Koordinatoren / Docker/Container Installationen mit weitergeleitetem Port wichtig.

                Bei start/stop darf das eigentlich nicht auftreten.

                A.

                Gaspode 1 Reply Last reply Reply Quote 0
                • Asgothian
                  Asgothian Developer @Gaspode last edited by

                  @gaspode sagte in Tester Zigbee Adapter 3.x gesucht:

                  In meinem Fall ist es ja ein den Sonoff CC2652P. Das Zigbee Netzwerk habe ich vorgestern auf einem neu installierten ioBroker und einem neu installierten Zigbee Adapter auf Github Stand (also V3) angelegt und die beiden Geräte neu angelernt. Jetzt habe ich den Coordinator auf die aktuelle FW gehoben. Und anschließend waren die Geräte nicht mehr verbunden. Dazu hab ich oben das Log gepostet, falls das interessant sein sollte.
                  Wie gesagt: Ich sage das im Zusammenhang mit dem Testaufruf der V3. Mein Produktivsystem läuft ja unter V3 stabil.

                  Das war mir so nicht zu 100% klar.

                  ich gehe im Moment davon aus das durch Öffnen des Netzes und triggern der Geräte bzw. alleine durch warten die Geräte auch wieder verbunden worden wären - der Adapter sichert die Einstellungen und spielt sie eigentlich auch in den Koordinator zurück.

                  A.

                  Gaspode 1 Reply Last reply Reply Quote 1
                  • Gaspode
                    Gaspode @Asgothian last edited by

                    @asgothian said in Tester Zigbee Adapter 3.x gesucht:

                    Sofern der Fehler nur bei test port auftritt ist das unkritisch. Diese Option ist primär für Netzwerk Koordinatoren / Docker/Container Installationen mit weitergeleitetem Port wichtig.
                    Bei start/stop darf das eigentlich nicht auftreten.

                    War nur bei Test. Die Fehlermeldung lässt halt vermuten, dass irgendwas nicht stimmt. Aber wenn man es weiß ...

                    1 Reply Last reply Reply Quote 0
                    • Gaspode
                      Gaspode @Asgothian last edited by

                      @asgothian said in Tester Zigbee Adapter 3.x gesucht:

                      der Adapter sichert die Einstellungen und spielt sie eigentlich auch in den Koordinator zurück.

                      D.h. das Log, das ich angehängt hatte, sieht OK aus?

                      Asgothian 1 Reply Last reply Reply Quote 0
                      • Asgothian
                        Asgothian Developer @Gaspode last edited by

                        @gaspode Zumindest habe ich darin keine Auffälligkeiten gefunden.

                        1 Reply Last reply Reply Quote 1
                        • First post
                          Last post

                        Support us

                        ioBroker
                        Community Adapters
                        Donate

                        932
                        Online

                        31.7k
                        Users

                        79.7k
                        Topics

                        1.3m
                        Posts

                        zigbee zigbee adapter
                        20
                        132
                        6272
                        Loading More Posts
                        • Oldest to Newest
                        • Newest to Oldest
                        • Most Votes
                        Reply
                        • Reply as topic
                        Log in to reply
                        Community
                        Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                        The ioBroker Community 2014-2023
                        logo