    Tester wanted - Zigbee Adapter 3.1

    This topic has been deleted. Only users with topic management privileges can see it.
    • F
      Flugschüler @Asgothian last edited by

      @asgothian Super gemacht. Wird das Gerät in den neuen Zigbee Adapter integriert? Soll ich den Adapter jetzt über git installiert lassen?

      Asgothian Thomas Braun 2 Replies Last reply Reply Quote 0
      • Asgothian
        Asgothian Developer @Flugschüler last edited by

        @flugschüler sobald die ganzen Nebeneffekte geklärt sind geht das erst ins latest, dann ins stable.

        D 1 Reply Last reply Reply Quote 0
        • Thomas Braun
          Thomas Braun Most Active @Flugschüler last edited by

          @flugschüler sagte in Tester wanted - Zigbee Adapter 3.1:

          Soll ich den Adapter jetzt über git installiert lassen?

          Ja. Wenn irgendwann über dein bevorzugtes Repository eine Version größer als die jetzige angeboten wird kommt die dann über deine regelmäßige Systempflege auf die Kiste.

          F 1 Reply Last reply Reply Quote 0
          • F
            Flugschüler @Thomas Braun last edited by

            @thomas-braun Ihr seid die besten👍

            1 Reply Last reply Reply Quote 0
            • D
              dimaiv @Asgothian last edited by dimaiv

              @asgothian sagte in Tester wanted - Zigbee Adapter 3.1:

              @dimaiv kannst du folgendes machen:

              • die aktuelle Github version installieren
              • nach dem Start eine ts0121 plug auf debug setzen
              • ein Device Query machen
              • Dann das Debug interface öffnen
                Screenshot 2025-09-20 at 14.31.24.png
              • mit dem button 1 aus dem Screenshot die Daten aktualisieren
              • in jeder Zeile bei incoming messages mit dem blauen Button 2 die Meldungen öffnen
              • aus dem Dialog heraus kopieren und hier Posten ?

              Danke.

              A.

              Screenshot (315).png

              
              I01: Zigbee Event of Type readResponse from device 0x60a423fffe61dd4a, incoming event: {"type":"readResponse","data":{"tuyaBacklightMode":1},"linkquality":87,"groupID":0,"cluster":"genOnOff","meta":{"rawData":{"type":"Buffer","data":[24,8,1,1,128,0,48,1]},"zclTransactionSequenceNumber":8,"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
              I02: 3 converters available for 'TS0121_plug' '60a423fffe61dd4a' with cluster 'genOnOff' and type 'readResponse'
              I03: message received '{"linkquality":87}' from device 60a423fffe61dd4a type 'TS0121_plug'
              I04: value generated '87' from device 60a423fffe61dd4a for 'Link quality'
              I02.1a: converter 1 : Cluster genOnOff
              I02.0b: data: {"tuyaBacklightMode":1} options: {} meta:{"deviceIEEE":"0x60a423fffe61dd4a","logger":"StatesController","state":{"state":""}} result:undefined
              I02.2a: converter 2 : Cluster genOnOff
              I02.1b: data: {"tuyaBacklightMode":1} options: {} meta:{"deviceIEEE":"0x60a423fffe61dd4a","logger":"StatesController","state":{"state":""}} result:undefined
              I02.3a: converter 3 : Cluster genOnOff
              I02.2b: data: {"tuyaBacklightMode":1} options: {} meta:{"deviceIEEE":"0x60a423fffe61dd4a","logger":"StatesController","state":{"state":""}} result:{"indicator_mode":"off/on"}
              I02.3c: candidates: [{},{},{"indicator_mode":"off/on"}] => payload {"indicator_mode":"off/on"}
              I03-1: message received '{"indicator_mode":"off/on"}' from device 60a423fffe61dd4a type 'TS0121_plug'
              I04-1: value generated '"off/on"' from device 60a423fffe61dd4a for 'LED indicator mode'
              
              
              
              I01: Zigbee Event of Type readResponse from device 0x60a423fffe61dd4a, incoming event: {"type":"readResponse","data":{"moesStartUpOnOff":0},"linkquality":87,"groupID":0,"cluster":"genOnOff","meta":{"rawData":{"type":"Buffer","data":[24,7,1,2,128,0,48,0]},"zclTransactionSequenceNumber":7,"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
              I02: 3 converters available for 'TS0121_plug' '60a423fffe61dd4a' with cluster 'genOnOff' and type 'readResponse'
              I03: message received '{"linkquality":87}' from device 60a423fffe61dd4a type 'TS0121_plug'
              I04: value generated '87' from device 60a423fffe61dd4a for 'Link quality'
              I02.1a: converter 1 : Cluster genOnOff
              I02.0b: data: {"moesStartUpOnOff":0} options: {} meta:{"deviceIEEE":"0x60a423fffe61dd4a","logger":"StatesController","state":{"state":""}} result:undefined
              I02.2a: converter 2 : Cluster genOnOff
              I02.1b: data: {"moesStartUpOnOff":0} options: {} meta:{"deviceIEEE":"0x60a423fffe61dd4a","logger":"StatesController","state":{"state":""}} result:{"power_outage_memory":"off"}
              I02.3a: converter 3 : Cluster genOnOff
              I02.2b: data: {"moesStartUpOnOff":0} options: {} meta:{"deviceIEEE":"0x60a423fffe61dd4a","logger":"StatesController","state":{"state":""}} result:undefined
              I02.3c: candidates: [{},{"power_outage_memory":"off"},{}] => payload {"power_outage_memory":"off"}
              I03-1: message received '{"power_outage_memory":"off"}' from device 60a423fffe61dd4a type 'TS0121_plug'
              I04-1: value generated '"off"' from device 60a423fffe61dd4a for 'Recover state after power outage'
              
              
              
              I01: Zigbee Event of Type readResponse from device 0x60a423fffe61dd4a, incoming event: {"type":"readResponse","data":{"onOff":0},"linkquality":87,"groupID":0,"cluster":"genOnOff","meta":{"rawData":{"type":"Buffer","data":[24,6,1,0,0,0,16,0]},"zclTransactionSequenceNumber":6,"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
              I02: 3 converters available for 'TS0121_plug' '60a423fffe61dd4a' with cluster 'genOnOff' and type 'readResponse'
              I03: message received '{"linkquality":87}' from device 60a423fffe61dd4a type 'TS0121_plug'
              I04: value generated '87' from device 60a423fffe61dd4a for 'Link quality'
              I02.1a: converter 1 : Cluster genOnOff
              I02.0b: data: {"onOff":0} options: {} meta:{"deviceIEEE":"0x60a423fffe61dd4a","logger":"StatesController","state":{"state":""}} result:{"state":"OFF"}
              I02.2a: converter 2 : Cluster genOnOff
              I02.1b: data: {"onOff":0} options: {} meta:{"deviceIEEE":"0x60a423fffe61dd4a","logger":"StatesController","state":{"state":""}} result:undefined
              I02.3a: converter 3 : Cluster genOnOff
              I02.2b: data: {"onOff":0} options: {} meta:{"deviceIEEE":"0x60a423fffe61dd4a","logger":"StatesController","state":{"state":""}} result:undefined
              I02.3c: candidates: [{"state":"OFF"},{},{}] => payload {"state":"OFF"}
              I03-1: message received '{"state":"OFF"}' from device 60a423fffe61dd4a type 'TS0121_plug'
              I04-1: value generated 'false' from device 60a423fffe61dd4a for 'On/off state of the switch'
              
              

              P.S.: ich glaube, die weiteren Daten bei diesen Steckdosen wurden immer gepoolt, und jetzt passiert es nicht.

              Asgothian 1 Reply Last reply Reply Quote 0
              • D
                dimaiv @Asgothian last edited by dimaiv

                @asgothian
                Was mir noch aufgefallen:

                Mit 3.1.2 kann ich über:

                sendToZigbee { "id": "zigbee.0.842e14fffedb8ae5", "ep": "1", "cid": "haElectricalMeasurement", "cmd": "read", "cmdType": "foundation", "zclData": { "activePower": {} } }

                Die weiteren Daten abrufen.

                Mit 3.1.3 von jetzt funktioniert es nicht.

                Screenshot (316).png

                Screenshot (317).png

                Das sind 2 absolut gleiche Steckdosen, unterschiedliche Installationen.

                1 Reply Last reply Reply Quote 0
                • Asgothian
                  Asgothian Developer @dimaiv last edited by

                  @dimaiv sagte in Tester wanted - Zigbee Adapter 3.1:

                  P.S.: ich glaube, die weiteren Daten bei diesen Steckdosen wurden immer gepoolt, und jetzt passiert es nicht.

                  Sind die Meldungen nach einem Device_query, oder kommen die normal so ?

                  @dimaiv sagte in Tester wanted - Zigbee Adapter 3.1:

                  Was mir noch aufgefallen:
                  Mit 3.1.2 kann ich über:
                  sendToZigbee { "id": "zigbee.0.842e14fffedb8ae5", "ep": "1", "cid": "haElectricalMeasurement", "cmd": "read", "cmdType": "foundation", "zclData": { "activePower": {} } }
                  Die weiteren Daten abrufen.
                  Mit 3.1.3 von jetzt funktioniert es nicht.

                  Danke für den Hinweis - ich hab im Hintergrund einiges Optimiert.

                  A.

                  D 1 Reply Last reply Reply Quote 0
                  • D
                    dimaiv @Asgothian last edited by

                    @asgothian sagte in Tester wanted - Zigbee Adapter 3.1:

                    Sind die Meldungen nach einem Device_query, oder kommen die normal so ?

                    A.

                    Die Meldungen sind nach einem Device_query, aber auch normal kommen nur die.

                    Asgothian 1 Reply Last reply Reply Quote 0
                    • Asgothian
                      Asgothian Developer @dimaiv last edited by

                      @dimaiv Ok, danke. Da scheint ein Konverter geändert - da muss ich im Detail graben, und Dir eine extra version machen. Wird aber etwas dauern.

                      A.

                      Asgothian 1 Reply Last reply Reply Quote 1
                      • Asgothian
                        Asgothian Developer @Asgothian last edited by Asgothian

                        @asgothian Zumindest der Developer Tab sollte jetzt wieder funktionieren.

                        Kannst du versuchen was passiert wenn du damit versuchst die Daten abzurufen ? Ob dann eine Meldung rein kommt ?

                        Interessant ist was genau an Antwort auf den Read Request rein kommt, wenn überhaupt etwas.

                        A.

                        D 1 Reply Last reply Reply Quote 0
                        • D
                          dimaiv @Asgothian last edited by dimaiv

                          @asgothian sagte in Tester wanted - Zigbee Adapter 3.1:

                          @asgothian Zumindest der Developer Tab sollte jetzt wieder funktionieren.

                          Kannst du versuchen was passiert wenn du damit versuchst die Daten abzurufen ? Ob dann eine Meldung rein kommt ?

                          Interessant ist was genau an Antwort auf den Read Request rein kommt, wenn überhaupt etwas.

                          A.

                          Über Entwikler Tab funktioniert jetzt:

                          
                          I01: Zigbee Event of Type readResponse from device 0x60a423fffe61dd4a, incoming event: {"type":"readResponse","data":{"activePower":0},"linkquality":51,"groupID":0,"cluster":"haElectricalMeasurement","meta":{"rawData":{"type":"Buffer","data":[24,8,1,11,5,0,41,0,0]},"zclTransactionSequenceNumber":8,"frameControl":{"frameType":0,"manufacturerSpecific":false,"direction":1,"disableDefaultResponse":true,"reservedBits":0}},"endpoint_id":1}
                          I02: 1 converter available for 'TS0121_plug' '60a423fffe61dd4a' with cluster 'haElectricalMeasurement' and type 'readResponse'
                          I03: message received '{"linkquality":51}' from device 60a423fffe61dd4a type 'TS0121_plug'
                          I04: value generated '51' from device 60a423fffe61dd4a for 'Link quality'
                          I02.1a: converter 1 : Cluster haElectricalMeasurement
                          I02.0b: data: {"activePower":0} options: {} meta:{"deviceIEEE":"0x60a423fffe61dd4a","logger":"StatesController","state":{"state":""}} result:{"power":0}
                          I02.1c: candidates: [{"power":0}] => payload {"power":0}
                          I03-1: message received '{"power":0}' from device 60a423fffe61dd4a type 'TS0121_plug'
                          I04-1: value generated '0' from device 60a423fffe61dd4a for 'Load power'
                          
                          

                          Uber die Scripte stürzt aber der Adapter ab mit folgender Meldung:

                          2025-09-21 21:40:50.830 - info: javascript.0 (942) script.js.Plug_abfragen: start JavaScript (Blockly)
                          2025-09-21 21:40:50.842 - info: javascript.0 (942) script.js.Plug_abfragen: registered 0 subscriptions, 0 schedules, 0 messages, 0 logs and 0 file subscriptions
                          2025-09-21 21:40:55.849 - error: zigbee.0 (282446) Unhandled promise rejection. This error originated either by throwing inside of an async function without a catch block, or by rejecting a promise which was not handled with .catch().
                          2025-09-21 21:40:55.851 - error: zigbee.0 (282446) unhandled promise rejection: Cannot read properties of undefined (reading 'replace')
                          2025-09-21 21:40:56.167 - error: zigbee.0 (282446) TypeError: Cannot read properties of undefined (reading 'replace')
                          at Developer.sendToZigbee (/opt/iobroker/node_modules/iobroker.zigbee/lib/developer.js:90:45)
                          at Developer.onMessage (/opt/iobroker/node_modules/iobroker.zigbee/lib/developer.js:49:26)
                          at Zigbee.emit (node:events:536:35)
                          at Zigbee.emit (node:domain:489:12)
                          at change (/opt/iobroker/node_modules/@iobroker/js-controller-adapter/src/lib/adapter/adapter.ts:11040:34)
                          at Immediate. (file:///opt/iobroker/node_modules/@iobroker/db-states-redis/src/lib/states/statesInRedisClient.ts:365:37)
                          at processImmediate (node:internal/timers:483:21)
                          2025-09-21 21:40:56.168 - error: zigbee.0 (282446) Cannot read properties of undefined (reading 'replace')
                          2025-09-21 21:40:56.193 - info: zigbee.0 (282446) Halting zigbee adapter. Restart delay is at least 30 seconds.
                          2025-09-21 21:40:56.193 - info: zigbee.0 (282446) cleaning everything up...
                          2025-09-21 21:40:56.196 - info: zigbee.0 (282446) Saved local configuration data
                          2025-09-21 21:40:56.227 - warn: zigbee.0 (282446) ELEVATED:I03 (2e22) message received '{"available":false}' from device 60a423fffe61dd4a type 'TS0121_plug'
                          2025-09-21 21:40:56.228 - warn: zigbee.0 (282446) ELEVATED:I04 (2e22) value generated 'false' from device 60a423fffe61dd4a for 'Available'
                          2025-09-21 21:40:56.229 - warn: zigbee.0 (282446) ELEVATED:I03 (2e22) message received '{"linkquality":0}' from device 60a423fffe61dd4a type 'TS0121_plug'
                          2025-09-21 21:40:56.230 - warn: zigbee.0 (282446) ELEVATED:I04 (2e22) value generated '0' from device 60a423fffe61dd4a for 'Link quality'
                          2025-09-21 21:40:56.586 - info: zigbee.0 (282446) Closing Zigbee network, 0 seconds remaining
                          2025-09-21 21:40:57.195 - warn: zigbee.0 (282446) Terminated (UNCAUGHT_EXCEPTION): Without reason
                          2025-09-21 21:40:57.783 - error: host.GartenIoB Caught by controller[1]: This error originated either by throwing inside of an async function without a catch block, or by rejecting a promise which was not handled with .catch(). The promise rejected with the reason:
                          2025-09-21 21:40:57.784 - error: host.GartenIoB Caught by controller[2]: TypeError: Cannot read properties of undefined (reading 'replace')
                          2025-09-21 21:40:57.784 - error: host.GartenIoB Caught by controller[2]: at Developer.sendToZigbee (/opt/iobroker/node_modules/iobroker.zigbee/lib/developer.js:90:45)
                          2025-09-21 21:40:57.784 - error: host.GartenIoB Caught by controller[2]: at Developer.onMessage (/opt/iobroker/node_modules/iobroker.zigbee/lib/developer.js:49:26)
                          2025-09-21 21:40:57.784 - error: host.GartenIoB Caught by controller[2]: at Zigbee.emit (node:events:536:35)
                          2025-09-21 21:40:57.785 - error: host.GartenIoB Caught by controller[2]: at Zigbee.emit (node:domain:489:12)
                          2025-09-21 21:40:57.785 - error: host.GartenIoB Caught by controller[2]: at change (/opt/iobroker/node_modules/@iobroker/js-controller-adapter/src/lib/adapter/adapter.ts:11040:34)
                          2025-09-21 21:40:57.785 - error: host.GartenIoB Caught by controller[2]: at Immediate. (file:///opt/iobroker/node_modules/@iobroker/db-states-redis/src/lib/states/statesInRedisClient.ts:365:37)
                          2025-09-21 21:40:57.785 - error: host.GartenIoB Caught by controller[2]: at processImmediate (node:internal/timers:483:21)
                          2025-09-21 21:40:57.785 - error: host.GartenIoB instance system.adapter.zigbee.0 terminated with code 6 (UNCAUGHT_EXCEPTION)
                          2025-09-21 21:40:57.785 - info: host.GartenIoB Restart adapter system.adapter.zigbee.0 because enabled
                          2025-09-21 21:41:01.905 - info: javascript.0 (942) script.js.Plug_abfragen: Stopping script
                          
                          

                          Blockly=>JS:

                          var Intervall;
                          
                          // Beschreibe diese Funktion …
                          async function Power() {
                            sendTo('zigbee.0', 'sendToZigbee', {
                              'parameter': { "id": "zigbee.0.60a423fffe61dd4a", "ep": "1", "cid": "haElectricalMeasurement", "cmd": "read", "cmdType": "foundation", "zclData": { "activePower": {} } },
                            });
                          }
                          
                          
                          Intervall = setInterval(async () => {
                            await Power();
                          }, 5000);
                          

                          Mit 3.1.2 funktionieren beide Variante.

                          Asgothian 1 Reply Last reply Reply Quote 0
                          • Asgothian
                            Asgothian Developer last edited by

                            @dimaiv Danke fürs Testen - ich schau mir das morgen an

                            1 Reply Last reply Reply Quote 0
                            • Asgothian
                              Asgothian Developer @dimaiv last edited by Asgothian

                              @dimaiv sagte in Tester wanted - Zigbee Adapter 3.1:

                              sendTo('zigbee.0', 'sendToZigbee', { 'parameter': { "id": "zigbee.0.60a423fffe61dd4a", "ep": "1", "cid": "haElectricalMeasurement", "cmd": "read", "cmdType": "foundation", "zclData": { "activePower": {} } }, });

                              Diese Methode die Funktion aufzurufen ist auf Dauer instabil - sie basiert darauf das interne Funktionen nicht geändert werden. Bitte teste, ob mit einer der 3.X Versionen der folgende Payload in send_payload das gewünschte Ergebnis bringt. Dieses ist als Ersatz für das 'sendToZigbee' implementiert worden

                              {
                                "read": {
                                  "cluster": "haElectricalMeasurement",
                                  "attributes": [
                                    "activePower"
                                  ]
                                }
                              }
                              

                              Nachtrag:

                              bist du sicher das dieser Code in 3.0.5 wirklich geht ?

                              var Intervall;
                               
                              // Beschreibe diese Funktion …
                               async function Power() {
                                 sendTo('zigbee.0', 'sendToZigbee', {
                                   'parameter': { "id": "zigbee.0.60a423fffe61dd4a", "ep": "1", "cid": "haElectricalMeasurement", "cmd": "read", "cmdType": "foundation", "zclData": { "activePower": {} } },
                                 });
                               }
                                
                                
                               Intervall = setInterval(async () => {
                                 await Power();
                               }, 5000);
                              

                              Hintergrund - es gab eine Anpassung am Blockly SendTo Block. Wo der vorher den Code

                              sendTo('zigbee.0', 'sendToZigbee', {"id": "zigbee.0.00be44fffeab0b87", "ep": "1", "cid": "haElectricalMeasurement", "cmd": "read", "cmdType": "foundation", "zclData": { "activePower": {} } },
                              );
                              

                              als Standard erzeugt hat, macht er jetzt

                               sendTo('zigbee.0', 'sendToZigbee', {
                                   'parameter': { "id": "zigbee.0.60a423fffe61dd4a", "ep": "1", "cid": "haElectricalMeasurement", "cmd": "read", "cmdType": "foundation", "zclData": { "activePower": {} } },
                                 });
                              

                              mit dem Standard Block. Um die alte Version zurück zu bekommen muss man den Namen der Variable im Block löschen.

                              Blockly Skript zum importieren als Beispiel:

                              <xml xmlns="https://developers.google.com/blockly/xml">
                                <block type="sendto_custom" id="+%Nw$~nnCWC@TlZQZ~]8" x="212" y="138">
                                  <mutation xmlns="http://www.w3.org/1999/xhtml" items="parameter"></mutation>
                                  <field name="INSTANCE">zigbee.0</field>
                                  <field name="COMMAND">sendToZigbee</field>
                                  <field name="LOG"></field>
                                  <field name="WITH_STATEMENT">FALSE</field>
                                  <value name="ARG0">
                                    <shadow type="text" id="](`*pMFJEuOLTeBJ5hZF">
                                      <field name="TEXT">{"id": "zigbee.0.00be44fffeab0b87", "ep": "1", "cid": "haElectricalMeasurement", "cmd": "read", "cmdType": "foundation", "zclData": { "activePower": {} } }</field>
                                    </shadow>
                                  </value>
                                  <next>
                                    <block type="sendto_custom" id="1o#t?S/@4Z_1R7G/YxW3">
                                      <mutation xmlns="http://www.w3.org/1999/xhtml" items=""></mutation>
                                      <field name="INSTANCE">zigbee.0</field>
                                      <field name="COMMAND">sendToZigbee</field>
                                      <field name="LOG"></field>
                                      <field name="WITH_STATEMENT">FALSE</field>
                                      <value name="ARG0">
                                        <shadow type="text" id="O`S)U?JPvg=x#CYYZI*r">
                                          <field name="TEXT">{"id": "zigbee.0.00be44fffeab0b87", "ep": "1", "cid": "haElectricalMeasurement", "cmd": "read", "cmdType": "foundation", "zclData": { "activePower": {} } }</field>
                                        </shadow>
                                      </value>
                                    </block>
                                  </next>
                                </block>
                              </xml>
                              
                              D Asgothian 2 Replies Last reply Reply Quote 0
                              • D
                                dimaiv @Asgothian last edited by dimaiv

                                @asgothian
                                Deine Blockly ist absolut identisch mit dem was ich oben gepostet habe, nur bei mir ist SendTo in eine funktion gepackt und anderes exportiert.
                                Aber es macht nix, beide Varianten bringen 3.1.3 zum Absturz, und mit 3.1.2 aus latest funktionieren einwandfrei.
                                Aber, das ist jetz auch egal, weil, Variante über send_payload funktioniert auch bei 3.1.3 , und ist einfacher einzurichten bei mehreren Steckdosen.

                                Hoffentlich, muss man es ab jetzt, nich dauerhaft benutzen und überall einrichten , und es wird, wie vorher, von alleine über Converter (Pooling) funktionieren .

                                P.S.: Problem mit send_payload bei SWV bin ich auch betroffen, aber ich verfolge es auf Git. Falls hier was zum testen gibt, oder du das Ventil zum debuggen haben möchtest/muss, sag Bescheid.

                                Asgothian 1 Reply Last reply Reply Quote 0
                                • Asgothian
                                  Asgothian Developer @Asgothian last edited by Asgothian

                                  Es gibt eine neue Version auf Github: 3.1.2-alpha-4.

                                  Folgende Anpassungen sollten da drin sein:

                                  • Fix für 'onEvent' Polling: Sollte diesen Issue (GitHub link) schliessen: (sowie die Probleme vor @dimaiv)
                                  • Fix für 'no configure on pairing' - neu dem Netzwerk hinzugefügte Devices sollten automatisch Konfiguriert werden.
                                  • Netzwerk am Router öffnen - da der ZH diese Funktion wieder bietet, ist sie (hoffentlich) auch wieder verfügbar. Ich kann das nur bedingt testen.
                                    Screenshot 2025-09-24 at 21.40.02.png
                                  • Icon download button in der Konfiguration des Adapters. Notwendig wenn ein Upload gemacht wird ohne den Adapter neu zu starten.
                                    Screenshot 2025-09-24 at 21.47.22.png
                                  • Neue Optionen (grün: verifiziert, Orange: Bedarf Tests die ich mangels Gerät aktuell nicht durchführen kann)
                                    Screenshot 2025-09-24 at 21.47.56.png
                                    -- Active availability check. Wie in diesem Issue (GitHub link) zu sehen scheint der ZHC Ping nicht immer gut zu laufen. Deswegen gibt es jetzt im Adapter wählbare alternative Methoden (incl. 'off')
                                    -- Time between activity Checks: Dieses ist eine Maximalzeit zwischen Ping Versuchen. Es gibt interne Verrechnungen abhängig davon wie viele Devices im Netz sind, wie oft ein Device nicht erreicht werden konnte und diese Zahl. Je höher die Zahl desto seltener wird jedes Device abgefragt.
                                    -- List devices at Start: Aktiviert / Deaktivert die lange Liste an aktiven Geräten und Gruppen bei Adapter-Start.
                                    -- try to read all states at adapter start: Dient dazu beim Start des Adapters zu versuchen den Status im ioBroker mit dem der Geräte zu synchronisieren. Kann bei grossen Netzen Problematisch werden. Dazu gehört: delay in seconds - die Verzögerung zwischen Adapter-Start und dem Start des Abfrage aller Geräte.
                                    -- Read States at device announce: Wenn ein Gerät sich am Netzwerk 'zurück' meldet (xxx has announced itself) wird ein Device-Query für das Device ausgelöst um dessen Status zu ermitteln.
                                    -- use channel for complex exposes: Dies ist eine zukünftige Entwicklung. Es gibt bei bestimmten Geräten Datenpuntke die eigentlich nur gemeinsam gesetzt werden dürfen. Ein Beispiel dafür sind Farben mit r, g, b - die schon als Channels angeboten werden. Dabei passiert folgendes:
                                    -- wird einer der States im Channel verändert so wird ein timeout gestartet. Bei Ablauf des Timeout werden alle eingetragenen Werte genommen und in einem Payload an das Gerät gesandt. Dabei ist die Zeit für den Timeout abhängig davon ob die Änderung 'manuell' im Admin passiert oder nicht. Im Admin liegt der Timeout zwischen 2.5 und 5 sekunden. Ausserhalb des Admin sind es 100 - 250 ms. Durch weitere Tests können sich diese Zahlen noch ändern.
                                  • Veränderungen an der Netzwerk-Karte: Der vorherige Regenerate button (blau) wurde durch einen grünen Reload button ersetzt. Dieser lädt eine bereits generierte Map vom Adapter anstatt diese neu vom Netzwerk anzufragen. Um eine Map vollständig neu aufzubauen gibt es in den Map-Einstellungen einen eigenen Button:
                                    Screenshot 2025-09-24 at 22.02.38.png
                                  • via den 'zigbee subsystem error' Anzeiger kann das Zigbee-Subsystem nun direkt gestartet werden, ohne auf die Hardware-seite zu gehen. Dieser button ist auch im Tab sichtbar wenn das Zigbee-System nicht läuft aber der Adapter schon. Screenshot 2025-09-24 at 22.04.59.png
                                  • Die Koordinator-Karte zeigt jetzt nicht nur an ob der Koordinator ansprechbar ist, sondern auch ob der Haken zum automatischen Start des Zigbee Subsystems gesetzt ist:
                                    --Haken gesetzt: Screenshot 2025-09-24 at 22.10.17.png
                                    -- Haken nicht gesetzt: Screenshot 2025-09-24 at 22.11.08.png
                                  • developer modus gefixed - sollte sauber gehen.
                                  • Gruppen aus der Auswahl im Developer Modus entfernt, da die Funktionalität so nicht nutzbar ist.
                                  1 Reply Last reply Reply Quote 0
                                  • Asgothian
                                    Asgothian Developer @dimaiv last edited by

                                    @dimaiv sagte in Tester wanted - Zigbee Adapter 3.1:

                                    @asgothian
                                    Deine Blockly ist absolut identisch mit dem was ich oben gepostet habe, nur bei mir ist SendTo in eine funktion gepackt und anderes exportiert.
                                    Aber es macht nix, beide Varianten bringen 3.1.3 zum Absturz, und mit 3.1.2 aus latest funktionieren einwandfrei.
                                    Aber, das ist jetz auch egal, weil, Variante über send_payload funktioniert auch bei 3.1.3 , und ist einfacher einzurichten bei mehreren Steckdosen.

                                    Hoffentlich, muss man es ab jetzt, nich dauerhaft benutzen und überall einrichten , und es wird, wie vorher, von alleine über Converter (Pooling) funktionieren .

                                    Bist du sicher das die den gleichen Code erzeugen ? Bei mir tun sie das nicht, und der von mir gepostetete code

                                    sendTo('zigbee.0', 'sendToZigbee', {"id": "zigbee.0.00be44fffeab0b87", "ep": "1", "cid": "haElectricalMeasurement", "cmd": "read", "cmdType": "foundation", "zclData": { "activePower": {} } },
                                    );
                                    

                                    sollte auch mit der aktuellen 3.1.3 laufen.

                                    Aber:

                                    Es gibt inzwischen eine 3.1.3-alpha-4, damit sollte hoffentlich das polling wieder laufen.

                                    A.

                                    D 1 Reply Last reply Reply Quote 0
                                    • D
                                      dimaiv @Asgothian last edited by

                                      @asgothian
                                      Adapter 3.1.3 alpha 4 stürzt sofort ab.

                                      1 Reply Last reply Reply Quote 0
                                      • First post
                                        Last post

                                      Support us

                                      ioBroker
                                      Community Adapters
                                      Donate

                                      905
                                      Online

                                      32.1k
                                      Users

                                      80.7k
                                      Topics

                                      1.3m
                                      Posts

                                      tester zhc zigbee zigbee 3.1
                                      12
                                      161
                                      4039
                                      Loading More Posts
                                      • Oldest to Newest
                                      • Newest to Oldest
                                      • Most Votes
                                      Reply
                                      • Reply as topic
                                      Log in to reply
                                      Community
                                      Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                      The ioBroker Community 2014-2023
                                      logo