    [Aufruf] IKEA-Trådfri Adapter testen

    This topic has been deleted. Only users with topic management privileges can see it.
    • Homoran
      Homoran Global Moderator Administrators last edited by

      @BuZZy:

      Ist es gewollt, dass transitionDuration immer wieder auf 0.5 zurück geht? `
      Die 0.5 sec sind der Default Wert von IKEA.

      AlCalzone hatte ganz zu Beginn mal die Zusammennhänge erklärt.

      Leider weiss ich das nicht mehr.

      Gruß Rainer

      1 Reply Last reply Reply Quote 0
      • AlCalzone
        AlCalzone Developer last edited by

        @nobse:

        Wenn ich den Adapter in der Console mit

        set DEBUG=node--client & node main.js –force --logs

        starte geht es. Alle Geräte lassen sich steuern.

        Starte ich den Adapter im iobroker geht er auf gelb und es läst sich nichts steuern. `
        WTF?! Geht es mit "node main.js –force --logs" ohne DEBUG?

        @BuZZy:

        Ist es gewollt, dass transitionDuration immer wieder auf 0.5 zurück geht? `
        @Homoran:

        Die 0.5 sec sind der Default Wert von IKEA. `
        Jein. Egal was ich da einstelle, beim nächsten Update sendet das Gateway immer 0,5 für die transitionDuration. Wir hatten anfangs mal drüber gesprochen ob ich das ignoriere und sind zu dem Schluss gekommen, es erst mal zu lassen wie es ist. Sollte kein Problem sein, den zu ignorieren.

        @bytec:

        ich habe ich mich heute mal mit dem Tradfri Adapter befasst bekomme ihn aber einfach nicht zum laufen. `
        Hast du auf Github ein Issue aufgemacht? Da scheint was nicht vollständig zu installiert sein. Bitte mal Adapter neu installieren und Logs davon posten.

        1 Reply Last reply Reply Quote 0
        • N
          nobse last edited by

          Hallo

          ja auch mit

          node main.js –force --log

          läuft alles super.

          1 Reply Last reply Reply Quote 0
          • AlCalzone
            AlCalzone Developer last edited by

            @nobse:

            node main.js –force --log `
            Das muss logs mit "s" heißen. Schau mal ob das nen Unterschied macht.

            1 Reply Last reply Reply Quote 0
            • N
              nobse last edited by

              Hups da habe ich das s vergessen

              hatte das so gestartet

              node main.js –force --logs

              1 Reply Last reply Reply Quote 0
              • AlCalzone
                AlCalzone Developer last edited by

                @BuZZy:

                Ist es gewollt, dass transitionDuration immer wieder auf 0.5 zurück geht? `
                Wenn du möchtest, darfst du mal den Adapter von folgender URL installieren

                https://github.com/AlCalzone/ioBroker.t … sitiontime

                und testen. Es gibt jetzt eine Option, die Transition Time nicht mehr zu überschreiben.

                Edit: hab selbst getestet, ist jetzt als 1.1.0 verfügbar.

                1 Reply Last reply Reply Quote 0
                • N
                  nobse last edited by

                  @Wildbill

                  Kann ich nicht bestätigen.

                  Ich habe einen Bewegungsmelder mit 2 Lampen gekoppelt.

                  Bewegungsmelder und beide Lampen werden in ioBroker angezeigt. Bei eine der Lampen gibt es ein Unterverzeichnis bei den Objecten mit dem namen lightbulb

                  hier gibt es den Eintrag state der auch gesetzt wird wenn Lampen aus ober ein sind.

                  Ich habe den Bewegungsmelder und die 2 Lampen in einer seperater Gruppe. Diese Gruppe wird auch in ioBroker angezeigt und hat auch den Eintrag state der scheinbar den Status des Bewegungsmelders wieder spiegelt.

                  Auch wird der Status der Lampen richtig in der App auf dem Handy abgezeigt.

                  Gruss Norbert

                  1 Reply Last reply Reply Quote 0
                  • AlCalzone
                    AlCalzone Developer last edited by

                    @nobse:

                    Diese Gruppe wird auch in ioBroker angezeigt und hat auch den Eintrag state der scheinbar den Status des Bewegungsmelders wieder spiegelt. `
                    Das würde mich wundern, da noch vor einer Weile der Bewegungsmelder gar keine Infos gesendet hat. Kannst du das nochmal genau beobachten (und wenn tatsächlich was kommt einen Debug-Log posten)?

                    1 Reply Last reply Reply Quote 0
                    • N
                      nobse last edited by

                      Also der Bewegungsmelder und die gekoppelten Lampen werden angezeigt.

                      Wie kann ich das LOG anzeigen der Adapter läuft ja bei mir nicht in ioBroker sondern in der Console.

                      1 Reply Last reply Reply Quote 0
                      • AlCalzone
                        AlCalzone Developer last edited by

                        @nobse:

                        Also der Bewegungsmelder und die gekoppelten Lampen werden angezeigt.

                        Wie kann ich das LOG anzeigen der Adapter läuft ja bei mir nicht in ioBroker sondern in der Console. `
                        In der Befehlszeile brauchst du die Option "–logs" und "--debug".

                        1 Reply Last reply Reply Quote 0
                        • N
                          nobse last edited by

                          Hier der Teil des logs bei auslösung bewegungsmelder

                          ping successful...
                            node-coap-client workOffSendQueue > queue empty +1s
                            node-coap-client:message ============================= +4s
                            node-coap-client:message received message +16ms
                            node-coap-client:message messageId: 55925 +0ms
                            node-coap-client:message token: 7c27b307 +0ms
                            node-coap-client:message code: 2.05 +0ms
                            node-coap-client:message type: 0 +0ms
                            node-coap-client:message version: 1 +0ms
                            node-coap-client:message options: +0ms
                            node-coap-client:message   [NumericOption] Observe (6): 2945 +0ms
                            node-coap-client:message   [NumericOption] Content-Format (12): 50 +0ms
                            node-coap-client:message   [NumericOption] Max-Age (14): 604800 +0ms
                            node-coap-client:message payload: +0ms
                            node-coap-client:message {"9001":"Treppenhaus 2","9002":1517682569,"9019":1,"9020":1517980639,"9003":65545,"9054":0,"5750":1,"3":{"0":"IKEA of Sweden","1":"TRADFRI bulb E27 W opal 1000lm","2":"","3":"1.2.214","6":1}} +0ms
                            node-coap-client:message ============================= +0ms
                            node-coap-client:message  +0ms
                          observeDevice > {"3":{"0":"IKEA of Sweden","1":"TRADFRI bulb E27 W opal 1000lm","2":"","3":"1.2.214","6":1},"5750":1,"9001":"Treppenhaus 2","9002":1517682569,"9003":65545,"9019":1,"9020":1517980639,"9054":0}
                          Accessory: checking if name is required...
                          Accessory: checking if createdAt is required...
                          Accessory: checking if instanceId is required...
                          Accessory: checking if type is required...
                          Accessory: checking if deviceInfo is required...
                          DeviceInfo: checking if firmwareVersion is required...
                          DeviceInfo: checking if manufacturer is required...
                          DeviceInfo: checking if modelNumber is required...
                          DeviceInfo: checking if power is required...
                          DeviceInfo: checking if serialNumber is required...
                          DeviceInfo: checking if manufacturer is required...
                          Accessory: checking if alive is required...
                          Accessory: checking if lastSeen is required...
                          Accessory: checking if otaUpdateState is required...
                          Unknown accessory type 1\. Please send this info to the developer with a short description of the device!
                          2018-02-07 19:44:07.585  - warn: tradfri.0 Unknown accessory type 1\. Please send this info to the developer with a short description of the device!
                            node-coap-client sending ACK for message 0xda75 +3s
                            node-coap-client sending high priority message 0xda75 +0ms
                            node-coap-client workOffSendQueue > queue empty +0ms
                           state with id tradfri.0.XYZ-65545.alive updated: ack=true; val=true
                            node-coap-client:message ============================= +15ms
                            node-coap-client:message received message +0ms
                            node-coap-client:message messageId: 55926 +0ms
                            node-coap-client:message token: 7c27b306 +0ms
                            node-coap-client:message code: 2.05 +0ms
                            node-coap-client:message type: 0 +0ms
                            node-coap-client:message version: 1 +0ms
                            node-coap-client:message options: +0ms
                            node-coap-client:message   [NumericOption] Observe (6): 2946 +0ms
                            node-coap-client:message   [NumericOption] Content-Format (12): 50 +0ms
                            node-coap-client:message   [NumericOption] Max-Age (14): 604800 +0ms
                            node-coap-client:message payload: +16ms
                            node-coap-client:message {"9001":"Treppenhaus 1","9002":1517682363,"9019":1,"9020":1517980646,"9003":65544,"9054":0,"5750":2,"3":{"0":"IKEA of Sweden","1":"TRADFRI bulb E27 W opal 1000lm","2":"","3":"1.2.214","6":1},"3311":[{"5850":1,"5851":254,"9003":0}]} +0ms
                            node-coap-client:message ============================= +0ms
                            node-coap-client:message  +0ms
                          observeDevice > {"3":{"0":"IKEA of Sweden","1":"TRADFRI bulb E27 W opal 1000lm","2":"","3":"1.2.214","6":1},"3311":[{"5850":1,"5851":254,"9003":0}],"5750":2,"9001":"Treppenhaus 1","9002":1517682363,"9003":65544,"9019":1,"9020":1517980646,"9054":0}
                          Accessory: checking if name is required...
                          Accessory: checking if createdAt is required...
                          Accessory: checking if instanceId is required...
                          Accessory: checking if type is required...
                          Accessory: checking if deviceInfo is required...
                          DeviceInfo: checking if firmwareVersion is required...
                          DeviceInfo: checking if manufacturer is required...
                          DeviceInfo: checking if modelNumber is required...
                          DeviceInfo: checking if power is required...
                          DeviceInfo: checking if serialNumber is required...
                          DeviceInfo: checking if manufacturer is required...
                          Accessory: checking if alive is required...
                          Accessory: checking if lastSeen is required...
                          Accessory: checking if otaUpdateState is required...
                          Accessory: checking if lightList is required...
                          Light: checking if name is required...
                          Light: checking if createdAt is required...
                          Light: checking if instanceId is required...
                          Light: checking if transitionTime is required...
                          Light: checking if onOff is required...
                          Light: checking if dimmer is required...
                          Light: checking if transitionTime is required...
                          Light: checking if onOff is required...
                            node-coap-client sending ACK for message 0xda76 +31ms
                            node-coap-client sending high priority message 0xda76 +0ms
                            node-coap-client workOffSendQueue > queue empty +0ms
                           state with id tradfri.0.XYZ-65545.lastSeen updated: ack=true; val=1517980639
                           state with id tradfri.0.L-65544.alive updated: ack=true; val=true
                           state with id tradfri.0.L-65544.lastSeen updated: ack=true; val=1517980646
                           state with id tradfri.0.L-65544.lightbulb.brightness updated: ack=true; val=100
                           state with id tradfri.0.L-65544.lightbulb.state updated: ack=true; val=true
                           state with id tradfri.0.L-65544.lightbulb.transitionDuration updated: ack=true; val=0.5
                           state with id tradfri.0.G-131077.brightness updated: ack=true; val=100
                           state with id tradfri.0.G-131077.state updated: ack=true; val=true
                            node-coap-client getConnection(coaps://192.168.133.103:5684) => found existing connection +6s
                            node-coap-client remembering request: msgID=0x36, token=, url=coaps://192.168.133.103:5684 +0ms
                            node-coap-client added message to the send queue with normal priority, new length = 1 +0ms
                            node-coap-client workOffSendQueue > concurrency = 0 (MAX 1) +0ms
                            node-coap-client concurrency low enough, sending message 0x36 +0ms
                            node-coap-client request 0x36: concurrency changed => 1 +0ms
                            node-coap-client:message ============================= +6s
                            node-coap-client:message received message +0ms
                            node-coap-client:message messageId: 54 +0ms
                            node-coap-client:message token:  +0ms
                            node-coap-client:message code: 0.00 +0ms
                            node-coap-client:message type: 3 +0ms
                            node-coap-client:message version: 1 +0ms
                            node-coap-client:message options: +0ms
                            node-coap-client:message payload: +0ms
                            node-coap-client:message  +0ms
                            node-coap-client:message ============================= +0ms
                            node-coap-client:message  +0ms
                            node-coap-client request 0x36: concurrency changed => 0 +0ms
                            node-coap-client workOffSendQueue > queue empty +16ms
                            node-coap-client received response to ping with ID 0x36 +0ms
                            node-coap-client forgetting request: token=; msgID=0x36 +0ms
                          ping successful...
                            node-coap-client workOffSendQueue > queue empty +1s
                          
                          

                          tradfri.0.XYZ-65545 = 2 Lampe

                          tradfri.0.L-65544 = 1 Lampe

                          tradfri.0.G-131077 = Gruppe in der sich die Geräte befinden

                          Wenn du mehr brauchst melde dich.

                          1 Reply Last reply Reply Quote 0
                          • W
                            Wildbill last edited by

                            Hi,

                            wie ich ja ein paar Posts später geschrieben habe, wird mir der Status der Lampe nun auch immer angezeigt, unabhängig davon ob sie vom Bewegungsmelder oder per ioBroker geschaltet wird. Warum das beim ersten Mal nicht der Fall war kann ich nicht nachvollziehen, auch da ließ sie sich ja vom Bewegungsmelder aus steuern und auch per APP/ioBroker, hat aber den Status nicht aktualisiert, wenn sie per BW geschaltet wurde.

                            Nur den Status vom BW selbst sehe ich im ioBroker nicht. Da hab ich nur die Datenpunkte alive und lastseen. Und in der Gruppe mit der Lampe und dem BW wird natürlich der Status angezeigt, aber das ist wohl der Lampe an sich, da er auch auf true geht, wenn ich die Lampe manuell ohne BW einschalte…

                            Aber für meine Zwecke tut es nun wie ich es brauche... :mrgreen:

                            Gruss, Jürgen

                            1 Reply Last reply Reply Quote 0
                            • AlCalzone
                              AlCalzone Developer last edited by

                              @nobse:

                              Hier der Teil des logs bei auslösung bewegungsmelder `
                              Ich sehe da keine Daten von einem Bewegungsmelder. Hast du möglicherweise nen Screenshot der Objekte für mich?

                              Interessant ist aber, dass er eine Lampe als Lampe erkennt (L-…) und die andere nicht (XYZ-...), trotz gleichem Typ. Das Paket vom Gateway sieht auch anders aus (enthält keine Infos über die Lampe).

                              Die "Konkurrenz" hat dieses Problem auch schon festgestellt: https://github.com/ggravlingen/pytradfri/issues/135

                              Ablernen und neu Anlernen der betroffenen Lampe sollte es beheben.

                              mhlund created this issue in ggravlingen/pytradfri

                              closed Lamps not identified as lamps with f/w 1.3.14 #135

                              1 Reply Last reply Reply Quote 0
                              • AlCalzone
                                AlCalzone Developer last edited by

                                @nobse: Ich habe eventuell eine Lösung für dein Problem. Bitte mal Version 1.1.1 installieren und testen, ob es jetzt läuft.

                                1 Reply Last reply Reply Quote 0
                                • AlCalzone
                                  AlCalzone Developer last edited by

                                  @nobse:

                                  TypeError: Generator is already running `
                                  Hattest du schon Gelegenheit, die neueste Version in ioBroker (ohne Konsole) zu testen?

                                  1 Reply Last reply Reply Quote 0
                                  • L
                                    ludino last edited by

                                    Tradfri Keine verbindung mehr.

                                    hi habe folgende fehler beim Verbinden.

                                    4298_tradfri.png

                                    Was ich bis dato gemacht habe,

                                    Tradfri adapter neu installiert,

                                    hat einer einde idee, woran es liegen könnte?

                                    gruß

                                    1 Reply Last reply Reply Quote 0
                                    • AlCalzone
                                      AlCalzone Developer last edited by

                                      @ludino:

                                      hat einer einde idee, woran es liegen könnte? `
                                      Hier die Lösung:

                                      http://forum.iobroker.net/viewtopic.php?p=90944#p90944

                                      1 Reply Last reply Reply Quote 0
                                      • L
                                        ludino last edited by

                                        @AlCalzone:

                                        @ludino:

                                        hat einer einde idee, woran es liegen könnte? `
                                        Hier die Lösung:

                                        http://forum.iobroker.net/viewtopic.php?p=90944#p90944 `

                                        Danke Dir, wenn du jetzt hier wärst würden wir jetzt ein kasten Bier auf meine Kosten leeren.

                                        1 Reply Last reply Reply Quote 0
                                        • N
                                          nobse last edited by

                                          @AlCalzone

                                          Sorry das ich mich erst jetzt melde hatte aber keine Zeit mich darum zu kümmern.

                                          Nach dem Update auf 1.1.3 läuft es jetzt unter ioBroker. Das ist schon mal super.

                                          Nach dem Update habe ich aber das Problem wenn ich die Farbe änder geht die Saturation aug 0 % und somit leuchtet die Lampe weiß.

                                          Zur Steuerung verwende ich das Widget Colorpicker Philips HUE.

                                          1 Reply Last reply Reply Quote 0
                                          • AlCalzone
                                            AlCalzone Developer last edited by

                                            Dein Problem könnte mit Homorans Problem in einem anderen Thread zu tun haben. Ich Arbeite an der Lösung

                                            Gesendet von unterwegs

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            855
                                            Online

                                            31.7k
                                            Users

                                            79.9k
                                            Topics

                                            1.3m
                                            Posts

                                            49
                                            471
                                            102043
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo