      Hallo,

      der rega-Adapter macht neuerdings ab und an Ärger:

      ` > hm-rega.0 2018-01-13 18:37:46.031 info time difference local-ccu 1s

      hm-rega.0 2018-01-13 18:37:16.246 info ReGaHSS 192.168.1.11 up

      hm-rega.0 2018-01-13 18:36:31.069 error CCU 192.168.1.11 unreachable

      hm-rega.0 2018-01-13 18:36:31.066 error post request error: read ECONNRESET `

      Danach ist er aus dem tritt, es kommen keine Ereignisse mehr an.

      Neustart des Adapters hilft. Der RPC-Adapter arbeitet tadellos weiter.

      Super erkennbar ist das an den Diagrammen, da wo Werte aus RPC geloggt werden,

      alles vollständig (z.B. Temperatur der Heizung), da wo z.B. Variablen-Inhalte geloggt werden,

      gibt es dann Lücken. Passiert seit ein paar Tagen / Wochen regelmäßig. (seit 26.12.2017)

      Ist übrigens die 1.6.6 die bei mir läuft.

      Hat das wer anderes schon beobachtet?

      1 Reply Last reply Reply Quote 0
      • sissiwup
        sissiwup last edited by

        Hier die Heilung des Symptoms (meine CCU hat die Adresse …11 am Ende):

        #!/bin/bash
        logfile=/opt/test-hang.log
        
        cd /opt/iobroker/log
        
        more `ls -t | head -1` | grep "11 unreachable" | wc -l > /opt/counthang.akt
        read akt < /opt/counthang.akt
        cd /opt
        
        if [ $(ls -1 /opt | grep -c counthang.old) = 0 ];
        then
          echo "$(date) Keine alte Datei, Akt: $akt: " >> $logfile
          cp /opt/counthang.akt /opt/counthang.old
          exit 0
        fi
        read old < /opt/counthang.old
        
        # echo "Alt: $old = Neu: $akt"
        cp /opt/counthang.akt /opt/counthang.old
        
        if [ $akt -gt $old ];
        then
          echo "Aktion!"  >> $logfile
          echo "$(date) $akt > $old" >> $logfile
          iobroker restart hm-rega.0 >> $logfile
          iobroker restart hm-rpc.0 >> $logfile
          iobroker restart hm-rpc.1 >> $logfile
        else
          touch $logfile
        fi
        
        

        Das Skript liegt in /opt Verzeichnis und läuft bei mir alle 5 Minuten:

        */5 *   * * *   root    /opt/test-hang.sh >> /opt/test-hang.log
        

        Das habe ich schon immer laufen um diverse Abbrüche zu beheben.

        Hier war der letzte Hänger allerdings im Jan. 2017, so daß es jetzt umgewidmet wurde.

        Es kann z.B. natürlich auch den cloud-Adapter neu Starten wenn er die Verbindung verliert.

        Das Skript zählt wie oft im Logfile das Ereignis aufgetreten ist, ist es häufiger als beim letzten mal

        dann führt es die Aktionen aus.

        1 Reply Last reply Reply Quote 0
        • Dutchman
          Dutchman Developer Most Active Administrators last edited by

          warum so umstaendlich ueber ein externens script ?

          Jeder adapter hat einen wert "connected" der auf false springt wen die verbindung abbricht, das kan man dan mit einem javascript sehr leicht in iObroker selber loesen um den adapter neu zu starten (oder eventuell ander funtionen wie push/mail/alarem whatever)

          ~Dutch

          1 Reply Last reply Reply Quote 0
          • sissiwup
            sissiwup last edited by

            Hallo,

            ja, aber macht er das nicht auch beim manuellen Neustarten des Adapters oder beim Restart des ioBrokers?

            Das script startet den Adapter nur neu wenn die Verbindung zur CCU unterbrochen wurde.

            Aus welchen Gründen auch immer, da die CCU erreichbar ist und das Netz auch stabil läuft.

            1 Reply Last reply Reply Quote 0
            • Dutchman
              Dutchman Developer Most Active Administrators last edited by

              @sissiwup:

              Hallo,

              ja, aber macht er das nicht auch beim manuellen Neustarten des Adapters oder beim Restart des ioBrokers?

              Das script startet den Adapter nur neu wenn die Verbindung zur CCU unterbrochen wurde.

              Aus welchen Gründen auch immer, da die CCU erreichbar ist und das Netz auch stabil läuft. `

              Das kommt auf dein Script an, ich Hager mit time outs dieses Verhalten bei Neustart ausgeschlossen

              –-----------------------

              Send from mobile device

              Das schöne ios hat Auto Korrektur zum k****

              Wer Schreibfehler findet darf sie behalten oder auf eBay verkaufen, mindest Umsatz 10% für die community

              1 Reply Last reply Reply Quote 0
              • sissiwup
                sissiwup last edited by

                Hallo,

                ok, aber zurück zum Thema: Stürzt bei jemanden anderen der REGA-Adapter auch öfters ab?

                Ist das Problem bekannt?

                1 Reply Last reply Reply Quote 0
                • K
                  KroKoFox last edited by

                  Hi, jub, kämpfe mit dem selben Problem.

                  hm-rega.0	2018-01-17 10:59:45.528	info	time difference local-ccu 1s
                  hm-rega.0	2018-01-17 10:59:45.494	info	ReGaHSS 192.168.178.11 up
                  hm-rpc.0	2018-01-17 10:59:40.275	info	Disconnected
                  hm-rega.0	2018-01-17 10:58:07.857	error	CCU 192.168.178.11 unreachable
                  hm-rega.0	2018-01-17 10:58:07.855	error	post request error: connect EHOSTUNREACH 192.168.178.11:8181
                  

                  habe ich sehr sporadisch … mal nach 2h mal nach 8h, man kann nicht sagen wann genau es immer passiert.

                  🙂

                  MODEdit by eric2905; Log-Auszüge bitte immer in Code- und ggf. Spoiler-Tags

                  1 Reply Last reply Reply Quote 0
                  • sissiwup
                    sissiwup last edited by

                    Problem tritt immer noch regelmäßig auf:

                    hm-rega.0	2018-02-14 21:02:48.418	error	CCU 192.168.1.11 unreachable
                    hm-rega.0	2018-02-14 21:02:48.415	error	post request error: connect ETIMEDOUT 192.168.1.11:8181
                    

                    Keiner eine Idee wodran es liegen kann?

                    1 Reply Last reply Reply Quote 0
                    • Homoran
                      Homoran Global Moderator Administrators last edited by

                      @sissiwup:

                      Keiner eine Idee wodran es liegen kann? `
                      An der CCU 😉

                      Der Adapter erreicht die CCU nicht.

                      Wenn dort nicht die Rega abgestürzt ist (was ich aber primär vermute) ein paar Fragen:

                      • hast du WLAN irgend wo mit im Spiel?

                      • oder DLAN?

                      Gruß

                      Rainer

                      1 Reply Last reply Reply Quote 0
                      • sissiwup
                        sissiwup last edited by

                        Hallo,

                        irgendwie kommt der Adapter nach dem Neustart nachts um 4:00 nicht in den tritt. 1x manuell neu gestartet läuft er erstmal wieder:

                        Hier das Log von ioBroker + CCU

                        Date,Facility,Severity,Host,Syslogtag,ProcessID,Messagetype,Message
                        "Today 09:17:41","16","3","iobroker","/usr/local/bin/node:","","1"," error: sql.0 Error: ER_NO_SUCH_TABLE: Table 'iobroker.undefined' doesn't exist"
                        "Today 09:17:41","16","3","iobroker","/usr/local/bin/node:","","1"," error: sql.0 Please wait till next data record is logged and reload."
                        "Today 09:17:34","16","3","iobroker","/usr/local/bin/node:","","1"," error: sql.0 Error: ER_NO_SUCH_TABLE: Table 'iobroker.undefined' doesn't exist"
                        "Today 09:17:34","16","3","iobroker","/usr/local/bin/node:","","1"," error: sql.0 Please wait till next data record is logged and reload."
                        "Today 08:00:01","16","3","ccu2.fritz.box","ReGaHss:","","1"," Error: IseHssDP::ReadValue: CallGetValue failed; sVal = {ADDRESS LEQ1013270 CONNECTED 1 DEFAULT 1 DESCRIPTION CCU2-Coprocessor DUTY_CYCLE 9 FIRMWARE_VERSION 2.8.5 TYPE CCU2} {ADDRESS NEQ1694131 CONNECTED 1 DEFAULT 0 DESCRIPTI"
                        "Today 08:00:01","16","3","ccu2.fritz.box","ReGaHss:","","1"," Error: IseXmlRpc::CallGetValue: XmlrpcTypeToIseVal failed [iseXmlRpc.cpp:1463]"
                        "Today 07:00:00","16","3","ccu2.fritz.box","ReGaHss:","","1"," Error: IseHssDP::ReadValue: CallGetValue failed; sVal = {ADDRESS LEQ1013270 CONNECTED 1 DEFAULT 1 DESCRIPTION CCU2-Coprocessor DUTY_CYCLE 0 FIRMWARE_VERSION 2.8.5 TYPE CCU2} {ADDRESS NEQ1694131 CONNECTED 1 DEFAULT 0 DESCRIPTI"
                        "Today 07:00:00","16","3","ccu2.fritz.box","ReGaHss:","","1"," Error: IseXmlRpc::CallGetValue: XmlrpcTypeToIseVal failed [iseXmlRpc.cpp:1463]"
                        "Today 06:00:01","16","3","ccu2.fritz.box","ReGaHss:","","1"," Error: IseHssDP::ReadValue: CallGetValue failed; sVal = {ADDRESS LEQ1013270 CONNECTED 1 DEFAULT 1 DESCRIPTION CCU2-Coprocessor DUTY_CYCLE 0 FIRMWARE_VERSION 2.8.5 TYPE CCU2} {ADDRESS NEQ1694131 CONNECTED 1 DEFAULT 0 DESCRIPTI"
                        "Today 06:00:01","16","3","ccu2.fritz.box","ReGaHss:","","1"," Error: IseXmlRpc::CallGetValue: XmlrpcTypeToIseVal failed [iseXmlRpc.cpp:1463]"
                        "Today 05:00:04","16","3","ccu2.fritz.box","ReGaHss:","","1"," Error: IseHssDP::ReadValue: CallGetValue failed; sVal = {ADDRESS LEQ1013270 CONNECTED 1 DEFAULT 1 DESCRIPTION CCU2-Coprocessor DUTY_CYCLE 1 FIRMWARE_VERSION 2.8.5 TYPE CCU2} {ADDRESS NEQ1694131 CONNECTED 1 DEFAULT 0 DESCRIPTI"
                        "Today 05:00:04","16","3","ccu2.fritz.box","ReGaHss:","","1"," Error: IseXmlRpc::CallGetValue: XmlrpcTypeToIseVal failed [iseXmlRpc.cpp:1463]"
                        
                        1 Reply Last reply Reply Quote 0
                        • apollon77
                          apollon77 last edited by

                          Das Log ist von der CCU … ?! Hat nichts mit dem h.rega Adapter zu tun?!

                          1 Reply Last reply Reply Quote 0
                          • sissiwup
                            sissiwup last edited by

                            Hallo,

                            die ccu läuft. Im iobroker gibt es keine Fehlermeldungen zu dem Zeitpunkten (log iobroker + ccu).

                            Wenn ich den rega-Adapter neu starte läuft es wieder.

                            Ich habe die Vermutung, dass er beim Neustart von iobroker nicht anständig wieder hochfährt?

                            1 Reply Last reply Reply Quote 0
                            • apollon77
                              apollon77 last edited by

                              Was genau läuft denn nicht in iobroker? Werden sysvars nicht aktualisiert oder was genau ist denn das Problem?

                              1 Reply Last reply Reply Quote 0
                              • sissiwup
                                sissiwup last edited by

                                @apollon77:

                                Was genau läuft denn nicht in iobroker? Werden sysvars nicht aktualisiert oder was genau ist denn das Problem? `

                                Hallo,

                                genau, die Werte die der REGA-Adapter zusteuert. Z.B. Variablen, oder DUTY-Cycle oder Programm-Ausführung

                                1 Reply Last reply Reply Quote 0
                                • Homoran
                                  Homoran Global Moderator Administrators last edited by

                                  @sissiwup:

                                  die ccu läuft. `
                                  Aber wahrscheinlich die rega darauf nicht mehr, wie ich bereits oben vermutet habe.

                                  Gruß

                                  Rainer

                                  1 Reply Last reply Reply Quote 0
                                  • sissiwup
                                    sissiwup last edited by

                                    @Homoran:

                                    @sissiwup:

                                    die ccu läuft. `
                                    Aber wahrscheinlich die rega darauf nicht mehr, wie ich bereits oben vermutet habe.

                                    Gruß

                                    Rainer `

                                    Hallo,

                                    aber ein Neustart Rega im iobroker behebt das Problem. An der ccu mache ich nix.

                                    1 Reply Last reply Reply Quote 0
                                    • Homoran
                                      Homoran Global Moderator Administrators last edited by

                                      Ich kenne mich mit den aktuellen Versionen auf CCU und RaspiMatic nicht aus.

                                      Daher weiss ich nicht ob da jetzt ggf. ein früher viel diskutierter Watchdog implementiert ist, der dort die Rega wieder startet.

                                      Dann wäre es möglich, dass durch den Absturz der Rega der Adapter die Verbindung verliert und abschaltet, dann die Rega wieder durch den Watchdog gestartet wird und bei einem restart des Adapters wieder alles läuft, bis das Ganze wieder von vorne los geht.

                                      Gruß

                                      Rainer

                                      1 Reply Last reply Reply Quote 0
                                      • R
                                        robsdobs last edited by

                                        Der Watchdog ist nicht integriert. Die RegaHss läuft auf RaspberryMatic mittlerweile sehr stabil.

                                        Ist denn die WebUI erreichbar? Soweit ich weiß, sieht man nur den blauen Startbildschirm, wenn die RegaHss nicht läuft.

                                        1 Reply Last reply Reply Quote 0
                                        • sissiwup
                                          sissiwup last edited by

                                          @robsdobs:

                                          Der Watchdog ist nicht integriert. Die RegaHss läuft auf RaspberryMatic mittlerweile sehr stabil.

                                          Ist denn die WebUI erreichbar? Soweit ich weiß, sieht man nur den blauen Startbildschirm, wenn die RegaHss nicht läuft. `

                                          Hallo,

                                          auf der CCU2 geht alles. CuxD läuft, Verbindung zu Gateways ist da, Anzeige geht.

                                          1 Reply Last reply Reply Quote 0
                                          • R
                                            robsdobs last edited by

                                            Ist die CCU/RaspberryMatic Firmware auf aktuellem Stand und auch der Adapter?

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Support us

                                            ioBroker
                                            Community Adapters
                                            Donate

                                            943
                                            Online

                                            31.6k
                                            Users

                                            79.5k
                                            Topics

                                            1.3m
                                            Posts

                                            7
                                            25
                                            2164
                                            Loading More Posts
                                            • Oldest to Newest
                                            • Newest to Oldest
                                            • Most Votes
                                            Reply
                                            • Reply as topic
                                            Log in to reply
                                            Community
                                            Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                            The ioBroker Community 2014-2023
                                            logo