    HomematicRPC 1.8 + REGA 2.0 testen

    This topic has been deleted. Only users with topic management privileges can see it.
    • eric2905
      eric2905 last edited by

      Wenn Du dem ersten Link oben (auf die Anleitung) folgst, hast Du den genauen Ablauf … sofern Du ein Linux-basiertes System (Raspi, usw.) hast.

      Aktuell sicher ist Node 8 und npm 6 - damit läuft alles stabil.

      Gruß,

      Eric

      Von unterwegs getippert

      1 Reply Last reply Reply Quote 0
      • Q
        quorle last edited by

        Ich hänge mich mal mit ein, da es bei mir auch nicht funktioniert.

        Aktuelles Setup:

        Raspberry PI mit pivccu-3 Version: 3.41.11

        Firewall:

        Firewall-Richtlinie: blockiert

        XML-RPC API: Kein Zugriff

        Homematic-Script API: Kein Zugriff

        Mediola: Kein Zugriff

        Port Freigabe: 42001, 48181

        IP-Adressen für eingeschränken Zugriff: die IP des ioBroker ist eingetragen

        HM-REGA liest alles bei einem Restart des Adapters, kann man in der LOG verfolgen, keine Fehler.

        5278_ccu-firewall.png

        5278_ccu-authentifizierung.png

        5278_einstellung_hm-rpc_rfd_1.png

        5278_einstellung_hm-rpc_rfd_2.png

        5278_log_iobroker_hm-rpc-rfd.png

        <u>Es sollte doch so sein, das der REGA-Adapter auch die HM-Geräte regelmäßig aktualisiert, dies sollte man doch im ioBroker sehen als zuletzt upgedatet. Hier sollte sich doch der Zeitstempel ändern?</u>

        1 Reply Last reply Reply Quote 0
        • foxriver76
          foxriver76 Developer last edited by

          Ich verstehe gerade den Fehler nicht. Im Screenshot hast du den Log auf hm-rpc gefiltert, es geht jedoch um Rega.. oder?

          Bitte Problem nochmal beschreiben und Log ab Adapterstart posten, am besten kopieren und hier in Code-Tags einfügen statt Screenshot.

          1 Reply Last reply Reply Quote 0
          • foxriver76
            foxriver76 Developer last edited by

            Und deine callback Adresse steht auf der Ip der CCU statt der IP deines ioBroker.

            1 Reply Last reply Reply Quote 0
            • Q
              quorle last edited by

              Ok, nochmal kurz zum Problem. Der REGA aktualisiert anscheind die ganzen STATES der Aktoren ( HKT´s ). Dies tut er aber nicht mehr. er aktualisiert nur einmal, wenn man den Adapter neu startet. Also es wird keine Ventilöffnung zum Beispiel aktualisiert

              Hier mal die LOG des REGA - Adapters in DEBUG-Mode nach einem Neustart

              hm-rega.0	2018-12-17 20:01:25.963	debug	<-- {"1242":{"Name":"AL-OEQ0705944%3A0.CONFIG_PENDING","AlState":0,"AlOccurrenceTime":"1970-01-01 01:00:00","LastTriggerTime":"1970-01-01 01:00:00","Operations":5,"AlTriggerDP":1241,"Parent":1239}, "
              hm-rega.0	2018-12-17 20:01:25.880	debug	--> !# alarms.fn !# !# Dieses Homematic-Script gibt eine Liste aller Alarm-Datenpunk
              hm-rega.0	2018-12-17 20:01:25.878	debug	--> alarms.fn
              hm-rega.0	2018-12-17 20:01:25.878	debug	create service messages
              hm-rega.0	2018-12-17 20:01:25.878	info	got state values
              hm-rega.0	2018-12-17 20:01:25.878	debug	<-- {"BidCos-RF.OEQ0705944%3A0.UNREACH":true, "BidCos-RF.OEQ0705944%3A0.STICKY_UNREACH":true, "BidCos-RF.OEQ0705944%3A0.CONFIG_PENDING":false, "BidCos-RF.OEQ0705944%3A0.LOWBAT":false, "BidCos-RF.O
              hm-rega.0	2018-12-17 20:01:25.801	debug	--> !# datapoints.fn 1.8 !# !# Dieses Homematic-Script gibt eine Liste aller Datenpu
              hm-rega.0	2018-12-17 20:01:25.801	debug	objectChange hm-rega.0.OEQ2300146.0.FIRMWARE_VERSION {"_id":"hm-rega.0.OEQ2300146.0.FIRMWARE_VERSION","type":"state","common":{"name":"hm-rega.0.OEQ2300146.0.FIRMWARE_VERSION","type":"string","read":t
              hm-rega.0	2018-12-17 20:01:25.801	debug	objectChange hm-rega.0.OEQ2300146.0.DEFAULT {"_id":"hm-rega.0.OEQ2300146.0.DEFAULT","type":"state","common":{"name":"hm-rega.0.OEQ2300146.0.DEFAULT","type":"boolean","read":true,"write":false,"role":"
              hm-rega.0	2018-12-17 20:01:25.801	debug	objectChange hm-rega.0.OEQ2300146.0.CONNECTED {"_id":"hm-rega.0.OEQ2300146.0.CONNECTED","type":"state","common":{"name":"hm-rega.0.OEQ2300146.0.CONNECTED","type":"boolean","read":true,"write":false,"r
              hm-rega.0	2018-12-17 20:01:25.801	debug	objectChange hm-rega.0.OEQ2300146.0.DUTY_CYCLE {"_id":"hm-rega.0.OEQ2300146.0.DUTY_CYCLE","type":"state","common":{"name":"hm-rega.0.OEQ2300146.0.DUTY_CYCLE","type":"number","read":true,"write":false,
              hm-rega.0	2018-12-17 20:01:25.801	debug	objectChange hm-rega.0.OEQ2300146 {"_id":"hm-rega.0.OEQ2300146","type":"device","common":{"name":"CCU2"},"native":{"ADDRESS":"OEQ2300146","TYPE":"CCU2"},"from":"system.adapter.hm-rega.0","ts":15450732
              hm-rega.0	2018-12-17 20:01:25.801	debug	--> datapoints.fn
              hm-rega.0	2018-12-17 20:01:25.801	info	request state values
              hm-rega.0	2018-12-17 20:01:25.801	info	added/updated 1 objects
              hm-rega.0	2018-12-17 20:01:25.800	debug	<-- {ADDRESS OEQ2300146 CONNECTED 1 DEFAULT 1 DESCRIPTION {} DUTY_CYCLE 8 FIRMWARE_VERSION 2.8.6 TYPE CCU2}
              hm-rega.0	2018-12-17 20:01:25.734	debug	--> !# dutycycle.fn 0.3 string stderr; string stdout; system.Exec("/bin/sh -c '" # '
              hm-rega.0	2018-12-17 20:01:25.732	debug	--> dutycycle.fn
              hm-rega.0	2018-12-17 20:01:25.729	debug	objectChange hm-rega.0.2625 {"_id":"hm-rega.0.2625","type":"state","common":{"name":"DutyCycle","type":"number","read":true,"write":true,"role":"state","min":-1,"max":100,"unit":"%","desc":"DutyCycle
              hm-rega.0	2018-12-17 20:01:25.729	debug	objectChange hm-rega.0.2336 {"_id":"hm-rega.0.2336","type":"state","common":{"name":"Temperaturvorgabe_Badezimmer","type":"number","read":true,"write":true,"role":"state","min":0,"max":65000,"unit":"º
              hm-rega.0	2018-12-17 20:01:25.729	debug	objectChange hm-rega.0.2160 {"_id":"hm-rega.0.2160","type":"state","common":{"name":"Temperaturvorgabe_Kind_2","type":"number","read":true,"write":true,"role":"state","min":0,"max":65000,"unit":"ºC","
              hm-rega.0	2018-12-17 20:01:25.729	debug	objectChange hm-rega.0.2033 {"_id":"hm-rega.0.2033","type":"state","common":{"name":"Abschaltung_HKT","type":"boolean","read":true,"write":true,"role":"state","desc":"Abschltung HKT,s OFF/ON","states"
              hm-rega.0	2018-12-17 20:01:25.729	debug	objectChange hm-rega.0.1756 {"_id":"hm-rega.0.1756","type":"state","common":{"name":"Temperaturvorgabe_Kind_1","type":"number","read":true,"write":true,"role":"state","min":0,"max":65000,"unit":"ºC","
              hm-rega.0	2018-12-17 20:01:25.729	debug	objectChange hm-rega.0.1755 {"_id":"hm-rega.0.1755","type":"state","common":{"name":"Tempvorgabe_Flur","type":"number","read":true,"write":true,"role":"state","min":0,"max":65000,"unit":"ºC","desc":"T
              hm-rega.0	2018-12-17 20:01:25.729	debug	objectChange hm-rega.0.1658 {"_id":"hm-rega.0.1658","type":"state","common":{"name":"Tempvorgabe_Wohnzimmer","type":"number","read":true,"write":true,"role":"state","min":0,"max":65000,"unit":"ºC","de
              hm-rega.0	2018-12-17 20:01:25.729	debug	objectChange hm-rega.0.1235 {"_id":"hm-rega.0.1235","type":"state","common":{"name":"${sysVarAlarmZone1}","type":"boolean","read":true,"write":true,"role":"state","desc":"${sysVarAlarmZone1Msg}","stat
              hm-rega.0	2018-12-17 20:01:25.723	debug	objectChange hm-rega.0.950 {"_id":"hm-rega.0.950","type":"state","common":{"name":"${sysVarPresence}","type":"boolean","read":true,"write":true,"role":"state","desc":"${sysVarPresenceMsg}","states":{"
              hm-rega.0	2018-12-17 20:01:25.723	debug	objectChange hm-rega.0.maintenance {"_id":"hm-rega.0.maintenance","type":"state","common":{"name":"Servicemeldungen","type":"number","read":true,"write":true,"role":"state","min":0,"max":65000,"desc":
              hm-rega.0	2018-12-17 20:01:25.723	debug	objectChange hm-rega.0.alarms {"_id":"hm-rega.0.alarms","type":"state","common":{"name":"Alarmmeldungen","type":"number","read":true,"write":true,"role":"state","min":0,"max":65000,"desc":"Anzahl Alar
              hm-rega.0	2018-12-17 20:01:25.723	debug	system.adapter.admin.0: logging true
              hm-rega.0	2018-12-17 20:01:25.723	info	deleted 0 variables
              hm-rega.0	2018-12-17 20:01:25.723	info	added/updated 11 variables
              hm-rega.0	2018-12-17 20:01:25.722	debug	<-- {"40":{"Name":"Alarmmeldungen","TypeName":"VARDP","DPInfo":"Anzahl%20Alarmmeldungen","Value":0,"ValueMin":0,"ValueMax":65000,"ValueUnit":"","ValueType":16,"ValueSubType":0,"ValueList":""}, "41":{
              hm-rega.0	2018-12-17 20:01:25.629	debug	--> !# devices.fn 1.4 !# !# Dieses Homematic-Script gibt eine Liste aller Geraete/Ka
              hm-rega.0	2018-12-17 20:01:25.625	debug	--> devices.fn
              hm-rega.0	2018-12-17 20:01:25.554	info	added/updated rooms to enum.rooms
              hm-rega.0	2018-12-17 20:01:25.552	debug	"1224": {"Name": "Wohnzimmer", "TypeName":"ENUM_ROOMS", "EnumInfo":"", "Channels":[{"Address":"OEQ1704782:4","Interface":"BidCos-RF"},{"Address":"OEQ1712335:4","Interface":"BidCos-RF"},{"Address":"OEQ
              hm-rega.0	2018-12-17 20:01:25.552	debug	"1234": {"Name": "Terasse", "TypeName":"ENUM_ROOMS", "EnumInfo":"", "Channels":[]},
              hm-rega.0	2018-12-17 20:01:25.552	debug	"1226": {"Name": "Schlafzimmer", "TypeName":"ENUM_ROOMS", "EnumInfo":"", "Channels":[]},
              hm-rega.0	2018-12-17 20:01:25.552	debug	"1225": {"Name": "K%FCche", "TypeName":"ENUM_ROOMS", "EnumInfo":"", "Channels":[]},
              hm-rega.0	2018-12-17 20:01:25.552	debug	"1228": {"Name": "Kind2", "TypeName":"ENUM_ROOMS", "EnumInfo":"", "Channels":[{"Address":"PEQ1190279:4","Interface":"BidCos-RF"},{"Address":"CUX1200006:1","Interface":"CUxD"}]},
              hm-rega.0	2018-12-17 20:01:25.552	debug	"1227": {"Name": "Kind1", "TypeName":"ENUM_ROOMS", "EnumInfo":"", "Channels":[{"Address":"OEQ1707146:4","Interface":"BidCos-RF"},{"Address":"CUX1200003:1","Interface":"CUxD"}]},
              hm-rega.0	2018-12-17 20:01:25.552	debug	"1232": {"Name": "Hauswirtschaft", "TypeName":"ENUM_ROOMS", "EnumInfo":"", "Channels":[]},
              hm-rega.0	2018-12-17 20:01:25.552	debug	"1233": {"Name": "Garten", "TypeName":"ENUM_ROOMS", "EnumInfo":"", "Channels":[{"Address":"CUX1200005:1","Interface":"CUxD"},{"Address":"CUX1300001:1","Interface":"CUxD"}]},
              hm-rega.0	2018-12-17 20:01:25.552	debug	"1231": {"Name": "Garage", "TypeName":"ENUM_ROOMS", "EnumInfo":"", "Channels":[]},
              hm-rega.0	2018-12-17 20:01:25.552	debug	"1716": {"Name": "Flur", "TypeName":"ENUM_ROOMS", "EnumInfo":"", "Channels":[{"Address":"OEQ1707764:4","Interface":"BidCos-RF"},{"Address":"CUX1200002:1","Interface":"CUxD"}]},
              hm-rega.0	2018-12-17 20:01:25.552	debug	"1229": {"Name": "B%FCro", "TypeName":"ENUM_ROOMS", "EnumInfo":"", "Channels":[]},
              hm-rega.0	2018-12-17 20:01:25.552	debug	<-- {"1230": {"Name": "Badezimmer", "TypeName":"ENUM_ROOMS", "EnumInfo":"", "Channels":[{"Address":"PEQ1190308:4","Interface":"BidCos-RF"},{"Address":"CUX1200004:1","Interface":"CUxD"}]},
              hm-rega.0	2018-12-17 20:01:25.519	debug	--> !# rooms.fn 1.2 !# !# Dieses Script gibt eine Liste der Raeume als JSON Objekt a
              hm-rega.0	2018-12-17 20:01:25.517	debug	--> rooms.fn
              hm-rega.0	2018-12-17 20:01:25.516	info	added/updated functions to enum.functions
              hm-rega.0	2018-12-17 20:01:25.513	debug	"1505": {"Name": "Zentrale%20CCU2","TypeName":"ENUM_FUNCTIONS", "EnumInfo": "", "Channels": []}}
              hm-rega.0	2018-12-17 20:01:25.513	debug	"1220": {"Name": "Verschluss","TypeName":"ENUM_FUNCTIONS", "EnumInfo": "Fensterkontakte", "Channels": [{"Address":"OEQ0705944:1","Interface":"BidCos-RF"}]},
              hm-rega.0	2018-12-17 20:01:25.513	debug	"1508": {"Name": "Taster","TypeName":"ENUM_FUNCTIONS", "EnumInfo": "Ein%20-%20Ausschalter", "Channels": []},
              hm-rega.0	2018-12-17 20:01:25.513	debug	"1507": {"Name": "Sicherheit","TypeName":"ENUM_FUNCTIONS", "EnumInfo": "Sicherheitseinrichtungen", "Channels": []},
              hm-rega.0	2018-12-17 20:01:25.513	debug	"1510": {"Name": "Licht","TypeName":"ENUM_FUNCTIONS", "EnumInfo": "Licht", "Channels": []},
              hm-rega.0	2018-12-17 20:01:25.513	debug	"1506": {"Name": "Klima","TypeName":"ENUM_FUNCTIONS", "EnumInfo": "Temperatur%20-%20und%20Feuchtesensoren", "Channels": [{"Address":"CUX1200006:1","Interface":"CUxD"},{"Address":"CUX1200004:1","Interf
              hm-rega.0	2018-12-17 20:01:25.513	debug	"1504": {"Name": "Heizung","TypeName":"ENUM_FUNCTIONS", "EnumInfo": "Thermostate", "Channels": [{"Address":"OEQ1704782:4","Interface":"BidCos-RF"},{"Address":"OEQ1707146:4","Interface":"BidCos-RF"},{"
              hm-rega.0	2018-12-17 20:01:25.513	debug	<-- {"1509": {"Name": "Energiemanagment","TypeName":"ENUM_FUNCTIONS", "EnumInfo": "Energiemessstellen", "Channels": []},
              hm-rega.0	2018-12-17 20:01:25.502	debug	--> !# functions.fn 1.3 !# !# Dieses Script gibt eine Liste der Gewerke als JSON Str
              hm-rega.0	2018-12-17 20:01:25.499	debug	--> functions.fn
              hm-rega.0	2018-12-17 20:01:25.499	info	added/updated 5 favorites to enum.favorites
              hm-rega.0	2018-12-17 20:01:25.495	debug	"ioBroker":{}}
              hm-rega.0	2018-12-17 20:01:25.495	debug	"Badezimmer":{"id":2095,"Channels":[{"Address":"PEQ1190308:4","Interface":"BidCos-RF"},{"Address":"CUX1200004:1","Interface":"CUxD"},2337,2336]}},
              hm-rega.0	2018-12-17 20:01:25.495	debug	"Wohnzimmer":{"id":1475,"Channels":[{"Address":"OEQ1712335:4","Interface":"BidCos-RF"},{"Address":"OEQ1704782:4","Interface":"BidCos-RF"},{"Address":"OEQ0705944:1","Interface":"BidCos-RF"},{"Address":
              hm-rega.0	2018-12-17 20:01:25.495	debug	"Flur":{"id":1993,"Channels":[{"Address":"OEQ1707764:4","Interface":"BidCos-RF"},1836,1755]},
              hm-rega.0	2018-12-17 20:01:25.495	debug	"Kinderzimmer%201":{"id":1877,"Channels":[{"Address":"OEQ1707146:4","Interface":"BidCos-RF"},{"Address":"CUX1200003:1","Interface":"CUxD"},2008,1756]},
              hm-rega.0	2018-12-17 20:01:25.495	debug	<-- {"Admin":{"Kinderzimmer%202":{"id":2463,"Channels":[{"Address":"PEQ1190279:4","Interface":"BidCos-RF"},{"Address":"CUX1200006:1","Interface":"CUxD"},2161,2160]},
              hm-rega.0	2018-12-17 20:01:25.472	debug	--> !# favorites.fn 1.1 !# !# Dieses Script gibt die Favoriten als JSON String aus !
              hm-rega.0	2018-12-17 20:01:25.469	debug	--> favorites.fn
              hm-rega.0	2018-12-17 20:01:25.468	info	time difference local-ccu 0s
              hm-rega.0	2018-12-17 20:01:25.464	debug	<-- 1545073285
              hm-rega.0	2018-12-17 20:01:25.391	debug	--> Write(system.Date("%F %X").ToTime().ToInteger());
              hm-rega.0	2018-12-17 20:01:25.390	info	ReGaHSS 192.168.2.114 up
              hm-rega.0	2018-12-17 20:01:25.291	info	subscribe hm-rpc.0.BidCoS-RF.50.PRESS_SHORT
              hm-rega.0	2018-12-17 20:01:25.263	info	starting. Version 2.0.0 in /opt/iobroker/node_modules/iobroker.hm-rega, node: v8.14.0
              
              1 Reply Last reply Reply Quote 0
              • foxriver76
                foxriver76 Developer last edited by

                Geräteeigenschaften z. B. Temperaturen von Thermostaten werden von hm-rpc übertragen. Und dass deine Änderungen nicht übertragen werden, liegt an der falschen Callback-Adresse (siehe Post zuvor).

                1 Reply Last reply Reply Quote 0
                • Q
                  quorle last edited by

                  Ich habe die callback-Adresse nun mal geändert und werde morgen einmal berichten, ob dies Abhilfe geschaffen hat.

                  Muss aber dazu sagen, dass dies so bei Firmware 2 ohne Probleme funktioniert hatte.

                  1 Reply Last reply Reply Quote 0
                  • foxriver76
                    foxriver76 Developer last edited by

                    @quorle:

                    Ich habe die callback-Adresse nun mal geändert und werde morgen einmal berichten, ob dies Abhilfe geschaffen hat.

                    Muss aber dazu sagen, dass dies so bei Firmware 2 ohne Probleme funktioniert hatte. `

                    Gib einfach nochmal Bescheid, falls es nicht geht. Dann schauen wir mal woran es noch liegen könnte.

                    1 Reply Last reply Reply Quote 0
                    • Q
                      quorle last edited by

                      Also jetzt wird alles wunderbar aktualisiert.

                      Aber kannst du kurz erläuter für was man die callback-Adresse eintragen muss und was die genau macht?

                      1 Reply Last reply Reply Quote 0
                      • foxriver76
                        foxriver76 Developer last edited by

                        @quorle:

                        Also jetzt wird alles wunderbar aktualisiert.

                        Aber kannst du kurz erläuter für was man die callback-Adresse eintragen muss und was die genau macht? `

                        Die callback Adresse brauchst du nur wenn du zb in einem Docker Container was laufen hast. Dann muss da die IP Adresse rein, an welche die CCU antworten soll. Deshalb wurden die Nachrichten an die falsche Ip versucht zu übermitteln.

                        1 Reply Last reply Reply Quote 0
                        • F
                          Farmer-cb last edited by

                          Hallo

                          hab meine HM adapter upgedatet, leider bekomme ich seitdem beim HM.Rega die Meldung:

                          init error: Error: response timeout

                          was mach ich da verkehrt??

                          hab 2 iobroker-maschinen im Multihost die HM-Adapter sind auf der Slave-maschine
                          4639_hm_version.jpg
                          4639_mg-rega_1.jpg
                          4639_mg-rega_2.jpg

                          die Log sieht so aus:

                          hm-rpc.0	2019-02-08 22:08:05.723	error	init error: Error: response timeout
                          hm-rpc.0	2019-02-08 22:07:35.719	error	init error: Error: response timeout
                          hm-rpc.0	2019-02-08 22:07:30.701	info	binrpc client is trying to connect to 192.168.113.125:2001/ with ["xmlrpc_bin://192.168.113.21:2001","hm-rpc.0"]
                          hm-rpc.0	2019-02-08 22:07:30.700	info	binrpc server is trying to listen on 192.168.113.21:2001
                          hm-rpc.0	2019-02-08 22:07:30.094	info	starting. Version 1.9.6 in /opt/iobroker/node_modules/iobroker.hm-rpc, node: v8.12.0
                          host.ioBroker-Feuerer2	2019-02-08 22:07:28.707	info	instance system.adapter.hm-rpc.0 started with pid 1969
                          host.ioBroker-Feuerer2	2019-02-08 22:07:28.698	info	"system.adapter.hm-rpc.0" enabled
                          host.ioBroker-Feuerer2	2019-02-08 22:07:28.698	info	object change system.adapter.hm-rpc.0
                          host.ioBroker-Feuerer2	2019-02-08 22:07:27.887	info	instance system.adapter.hm-rpc.0 terminated with code 0 (OK)
                          hm-rpc.0	2019-02-08 22:07:27.865	info	binrpc -> 192.168.113.125:2001/ init ["xmlrpc_bin://192.168.113.21:2001",""]
                          hm-rpc.0	2019-02-08 22:07:27.848	info	binrpc -> 192.168.113.125:2001/ init ["xmlrpc_bin://192.168.113.21:2001",""]
                          
                          1 Reply Last reply Reply Quote 0
                          • foxriver76
                            foxriver76 Developer last edited by

                            Insofern deine CCU aktuell ist, läuft rfd nur noch mittels XML rpc und nicht mehr bin.

                            1 Reply Last reply Reply Quote 0
                            • F
                              Farmer-cb last edited by

                              hallo

                              leider immer noch das selbe

                              hm-rpc.0	2019-02-08 23:05:32.238	debug	xmlrpc -> 192.168.113.125:2001/ init ["http://192.168.113.21:2001","hm-rpc.0"]
                              hm-rpc.0	2019-02-08 23:05:18.663	error	init error: Error: read ECONNRESET
                              hm-rpc.0	2019-02-08 23:05:02.234	debug	xmlrpc -> 192.168.113.125:2001/ init ["http://192.168.113.21:2001","hm-rpc.0"]
                              hm-rpc.0	2019-02-08 23:04:32.229	debug	xmlrpc -> 192.168.113.125:2001/ init ["http://192.168.113.21:2001","hm-rpc.0"]
                              hm-rpc.0	2019-02-08 23:04:02.224	debug	xmlrpc -> 192.168.113.125:2001/ init ["http://192.168.113.21:2001","hm-rpc.0"]
                              hm-rpc.0	2019-02-08 23:03:32.222	debug	start connecting interval
                              hm-rpc.0	2019-02-08 23:03:32.222	debug	xmlrpc -> 192.168.113.125:2001/ init ["http://192.168.113.21:2001","hm-rpc.0"]
                              hm-rpc.0	2019-02-08 23:03:32.222	debug	Connect...
                              hm-rpc.0	2019-02-08 23:03:32.222	info	xmlrpc client is trying to connect to 192.168.113.125:2001/ with ["http://192.168.113.21:2001","hm-rpc.0"]
                              hm-rpc.0	2019-02-08 23:03:32.221	info	xmlrpc server is trying to listen on 192.168.113.21:2001
                              hm-rpc.0	2019-02-08 23:03:31.791	info	starting. Version 1.9.6 in /opt/iobroker/node_modules/iobroker.hm-rpc, node: v8.12.0
                              
                              
                              foxriver76 1 Reply Last reply Reply Quote 0
                              • foxriver76
                                foxriver76 Developer @Farmer-cb last edited by

                                @Farmer-cb ist die Authentifizierung in der CCU eingestellt? Falls ja, muss https genutzt (Port wird dann auch auf 42001 geändert) werden und die Nutzerdaten angegeben werden oder alternativ die Authentifizierung abgeschaltet werden. Glaube in den CCU Einstellungen unter Sicherheit ist das.

                                1 Reply Last reply Reply Quote 1
                                • F
                                  Farmer-cb last edited by

                                  nein, ist nicht aktiviert

                                  1 Reply Last reply Reply Quote 0
                                  • W
                                    Wlad @foxriver76 last edited by Wlad

                                    @foxriver76
                                    Danke sehr
                                    Super erklärt, das hat mir sehr geholfen

                                    1 Reply Last reply Reply Quote 0
                                    • First post
                                      Last post

                                    Support us

                                    ioBroker
                                    Community Adapters
                                    Donate

                                    652
                                    Online

                                    31.7k
                                    Users

                                    79.8k
                                    Topics

                                    1.3m
                                    Posts

                                    10
                                    83
                                    11680
                                    Loading More Posts
                                    • Oldest to Newest
                                    • Newest to Oldest
                                    • Most Votes
                                    Reply
                                    • Reply as topic
                                    Log in to reply
                                    Community
                                    Impressum | Datenschutz-Bestimmungen | Nutzungsbedingungen
                                    The ioBroker Community 2014-2023
                                    logo